WorldWideScience

Sample records for mit konventioneller radiographie

  1. The role of whole body spiral CT in the primary work-up of polytrauma patients - comparison with conventional radiography and abdominal sonography; Die Rolle der Ganzkoerper-Spiral-CT bei der Primaerdiagnostik polytraumatisierter Patienten - Vergleich mit konventioneller Radiographie und Abdomensonographie

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, T.; Schlippenbach, J. von; Wolf, K.J. [Klinik und Poliklinik fuer Radiologie und Nuklearmedizin, Charite - Campus Benjamin Franklin (Germany); Stahel, P.F.; Ertel, W. [Klinik fuer Unfall- und Wiederherstellungschirurgie, Charite - Campus Benjamin Franklin (Germany)

    2004-08-01

    Purpose: To evaluate the role of routine 'whole body spiral CT' in the primary work-up of polytrauma patients for injuries of the thorax, abdomen and spine, and to compare the results with those of conventional radiography of the chest and spine and abdominal ultrasound. Materials and Methods: Fifty consecutive polytrauma patients underwent contrast-enhanced single slice spiral CT (5 mm collimation) from the vertex to the floor of the pelvis as part of the primary work-up after emergency room admission. Overlapping high resolution sections and sagittal reformations of the spine were obtained. Reports of additional chest radiographs (n=43), abdominal ultrasound examinations (n=47) and spine radiographs (n=36) performed in the emergency room were available for retrospective comparison. The 'final diagnoses', which served as the standard of reference, were taken from the patients' records using all information that became available until discharge or death, such as findings from further imaging, surgery and autopsy. Results: CT showed 109 (97%) of 112 thoracic and abdominal soft-tissue injuries. Relevant injuries missed were an early splenic laceration and an early pelvic hematoma, both of which became clinically apparent several hours later. There were 4 false positive CT findings. Conventional chest radiography demonstrated only 20% of thoracic and sonography 22% of abdominal injuries. Chest radiography and sonography produced 2 false-positive findings each. CT showed 66 (87%) of 76 vertebral fractures including all 19 unstable ones. CT missed 5 anterior vertebral body and 5 spinous/transverse process fractures. Conventional radiography found 71% of vertebral fractures including only 50% of the unstable one. (orig.)

  2. Fundamental investigations for a OWC-tidal power plant with a conventional hydraulic turbine; Basisuntersuchungen fuer ein OWC-Wellenenergiekraftwerk mit konventioneller Hydroturbine. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Graw, K.U.; Lengricht, J.; Schimmels, S.

    2001-07-01

    At the present the OWC-tidal power plant is the most forward-looking way of converting tidal energy into usable electric power. Current research works focus on the dimensions of the structures in terms of occurring loads, the minimisation of hydraulic losses and the development of new turbine-generator types. The development of all air-turbine systems, which have been investigated so far, is considered as problematic and the commercialisation is likely to be a hindrance. Based on international research results an inventory tata of available hydraulic turbines is supposed to be gathered and fundamental investigations are supposed to check, if the application of conventional hydraulic turbines are an energetic progress in the OWC-tidal power plant. In order to considerably increase the efficiency compared to current developments, small-scale investigations at a physical model are supposed to show if and how a hydraulic turbine can be realised in a OWC-tidal power plant and how a concept of flow rectification as well as a flow-optimised form of inflow and outflow chambers can be achieved. (orig.) [German] Das OWC-Wellenenergiekraftwerk ist der zur Zeit zukunftstraechtigste Typ zur Umwandlung von Wellenenergie in nutzbaren Strom. Die laufenden Forschungsarbeiten beschaeftigen sich insbesondere mit der Dimensionierung der Strukturen hinsichtlich auftretender Belastungen, der Minimierung der hydraulischen Verluste und der Entwicklung von neuartigen Turbinen-Generatoren-Typen. Die Entwicklung aller bisher untersuchten Luftturbinensysteme wird jedoch als problematisch und die Kommerzialisierung hindernd angesehen. Aufbauend auf den internationalen Forschungsergebnissen sollen eine Bestandaufnahme der verfuegbaren Hydroturbinen durchgefuehrt und mit Baisuntersuchungen geprueft werden, ob ein Einsatz konventionaller Hydroturbinen im OWC-Wellenenergiekraftwerk eine energetische Weiterentwicklung darstellen kann. Um den Wirkungsgrad gegenueber derzeitigen Entwicklungen

  3. Diagnostic imaging in polytrauma: comparison of radiation exposure from whole-body MSCT and conventional radiography with organ-specific CT; Radiologische Bildgebung beim Polytrauma: Dosisvergleich von Ganzkoerper-MSCT und konventionellem Roentgen mit organspezifischer CT

    Energy Technology Data Exchange (ETDEWEB)

    Wedegaertner, U.; Lorenzen, M.; Weber, C.; Adam, G. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany); Nagel, H.D. [Philips Medizin Systeme GmbH, Hamburg (Germany)

    2004-07-01

    Purpose: To compare the radiation dose of whole-body multislice CT (MSCT) and conventional radiography with organ-specific CT in polytrauma. Materials and Methods: The whole-body MSCT encompassing brain, neck and midface, chest, abdomen and pelvis was performed on a Somatom Volume Zoom (Siemens). Conventional radiography consisted of chest and cervical, thoracic and lumbar spine in two views as well as pelvis. Polymat, Siemens. Three combinations of organ specific CT were chosen: CT examination of (1) head and cervical spine, (2) head, cervical spine and chest, (3) head, cervical spine and abdomen. The effective doses of whole-body MSCT and conventional radiography with organ-specific CT were calculated. Results: Effective doses were 20 mSv for whole-body MSCT, 2 mSv for conventional x-ray, and 5 mSv for combination (1), 8 mSv for combination (2) and (3) 16 mSv for combination (3) of the organ-specific CT. The ratio of radiation dose between whole-body MSCT and radiography was 10: 1. This ratio was reduced to 3: 1, 2: 1 and 1: 1 when a combination of radiography and CT was performed. Conclusions: Whole-body MSCT in polytrauma compared to conventional radiography with organ-specific CT induces a threefold increased dose in unfavorable situations and no increased dose in favorable situations. Nevertheless, routine use of whole-body MSCT should be critically evaluated and should be adapted to the clinical benefit. (orig.) [German] Ziel: Dosisvergleich von Ganzkoerper-MSCT und konventioneller Basisdiagnostik mit organspezifischen Ct-Untersuchungen beim Polytrauma. Material und Methoden: Die Ganzkoerper-MSCT-Untersuchung von Schaedel, Mittelgesicht, HWS sowie Thorax, Abdomen und Becken erfolgte an einem Somatom-Volume-Zoom (Siemens). Die konventionelle Bildgebung, bestehend aus Thorax, Becken, HWS, BWS und LWs, wurde an einem Siemens-Polymat durchgefuehrt. Fuer die organspezifischen CT-Untersuchungen wurden 3 Kombinationen ausgewaehlt: (1) CCT + HWS, (2) CCT + HWS

  4. Evaluation of direct radiographic magnification (DIMA) in the early detection of inflammatory rheumatic lesions. Comparison with the high-resolution conventional technique. Wertigkeit der direktradiographischen Vergroesserung (DIMA) bei der Fruehdetektion entzuendlich-rheumatischer Laesionen. Vergleichende Evaluation mit hochaufloesender konventioneller Aufnahmetechnik

    Energy Technology Data Exchange (ETDEWEB)

    Link, T.M. (Westfaelische Wilhelms-Universitaet Muenster (Germany). Institut fuer Klinische Radiologie); Fiebich, M. (Westfaelische Wilhelms-Universitaet Muenster (Germany). Institut fuer Klinische Radiologie); Gaubitz, M. (Westfaelische Wilhelms-Universitaet Muenster (Germany). Medizinische Klinik und Poliklinik B); Krause, F. (Westfaelische Wilhelms-Universitaet Muenster (Germany). Institut fuer Klinische Radiologie); Vestring, T. (Westfaelische Wilhelms-Universitaet Muenster (Germany). Institut fuer Klinische Radiologie); Schneider, M. (Westfaelische Wilhelms-Universitaet Muenster (Germany). Medizinische Klinik und Poliklinik B); Peters, P.E. (Westfaelische Wilhelms-Universitaet Muenster (Germany). Institut fuer Klinische Radiologie)

    1994-07-01

    Rheumatological joint disorders were examined with mammographic film-screen combinations and high-definition microfocal magnification radiography. Our objective was to evaluate the potentials of magnification radiography in diagnosing arthritis by means of interobserver and ROC analysis. The microfocal X-ray unit had a spot size of 20-130 [mu]m; 5-fold magnification was performed. Digital luminescence radiography was employed; digital image processing included simulation of conventional technique and edge enhancement. Eighty radiographs were obtained with conventional and magnification technique. All films were analyzed by five readers. Anatomical and pathological structures were evaluated. The percentage of uncertain findings in magnification radiography was lower compared to conventional radiographs (14% to 26%); in 8% (compared to 19%) the diagnosis of erosions was uncertain. Additionally ROC analysis was carried out. Magnification radiography was significantly (p < 0.03) better than the conventional films. (orig.)

  5. ROC comparison of visualisation of fractures of the hand via digital and conventional techniques; ROC-Vergleich der Erkennbarkeit von Frakturen der Hand mittels digitaler und konventioneller Technik

    Energy Technology Data Exchange (ETDEWEB)

    Hofstetter, H. [Stadtspital Triemli, Zurich (Switzerland). Inst. fuer Roentgendiagnostik; Voegeli, E. [Kantonspital, Luzern (Switzerland). Roentgeninstitut

    1997-09-01

    Purpose: To compare the accuracy of digital luminescence radiography (DLR) and conventional film-screen radiography (FSR) in diagnosing fractures. Material and method: Both conventional and digital radiographs were acquired from a consecutive series of 57 patients with suspected wrist or hand fractures. The digital images were obtained with a 30% dose reduction. A ROC-analysis (receiver-operating characteristics) was performed. Results: The area under the curve was 0.89 for conventional FSR, 0.93 for DLR, `gray scale` and 0.94 for DLR, `edge enhanced`. (orig./AF) [Deutsch] Ziel: Vergleich der diagnostischen Sicherheit der digitalen Lumineszenzradiographie (DLR) mit der konventionellen Film-Folien-Technik (FFT) in der Beurteilung frischer ossaerer Laesionen nach Trauma im Handbereich. Material und Methodik: Bei 57 Patienten wurden sowohl konventionelle als auch digitale Aufnahmen des Unterarmes respektive der Hand durchgefuehrt. Die digitalen Aufnahmen wurden mit einer gegenueber der FFT um 30% geringeren Expositionsdosis angefertigt. Eine ROC-Studie. Ergebnisse: Die Flaeche unter der ROC-Kurve betrug fuer die FFT 0,89, fuer die DLR, konventionell angeglichen 0,94 und fuer die DLR, kantenbetont 0,95. (orig./AJ)

  6. Reduction of radiation dose by using digital luminescence radiography compared to conventional screen film system with grid cassette; Reduktion der Strahlendosis mittels Speicherfolienradiographie im Vergleich zum konventionellen Film-Folien-System mit Rasterkassette am Schaedelphantom

    Energy Technology Data Exchange (ETDEWEB)

    Heyne, J.P.; Merbold, H.; Neumann, R.; Freesmeyer, M.; Jonetz-Mentzel, L.; Kaiser, W.A. [Friedrich-Schiller-Univ. Jena, Inst. fuer Diagnostische und Interventionelle Radiologie (Germany); Sehner, J. [AGFA-Deutschland, Vertriebsgesellschaft (Germany)

    1999-07-01

    Purpose: How much can the radiation dose be reduced for skull radiography by using digital luminescence radiography (DLR) compared to a conventional screen film system with a grid cassette? Methods and Materials: A skull phantom (3M) was X-rayed in anterior-posterior orientation using both a conventional screen film system with grid cassette and DLR (ADC-70, Agfa). The tube current time product (mAs) was diminished gradually while keeping the voltage constant. The surface entrance dose was measured by a sensor of Dosimax (Wellhoefer). Five investigators evaluated the images by characteristic and critical features, spatial resolution and contrast. Results: The surface entrance dose at 73 kV/22 mAs was 0,432 mGy in conventional screen film system and 0,435 mGy in DLR. The images could be evaluated very well down to an average dose of 71% (0,308 mGy; SD 0,050); sufficient images were obtained down to an average dose of 31% (0,136 mGy; SD 0,065). The resolution of the line pairs were reduced down to a 2 levels depending on the investigator. Contrast was assessed as being very good to sufficient. The acceptance of the postprocessed images (MUSICA-software) was individually different and resultde in an improvement of the assessment of bone structures an contrast in higher dose ranges only. Conclusion: For the sufficient assessment of a possible fracture/of paranasal sinuses/of measurement the skull the dose can be reduced to at least 56% (31%; SD 14,9%)/40% (27%; SD 9,3%)/18% (14%; SD 4,4%). Digital radiography allows question-referred exposure parameters with clearly reduced dose, so e.g. for fracture exclusion 73 kV/12,5 mAs and to skull measurement 73 kV/4 mAs. (orig.) [Deutsch] Ziel: Wie weit kann unter Einsatz der rasterlosen Speicherfolienradiographie bei einer Schaedelaufnahme die Strahlendosis im Vergleich zum Film-Folien-System (FFS) mit Rasterkassette (RK) fragestellungsbezogen gesenkt werden? Material und Methode: Ein Schaedelphantom (3M) wurde konventionell

  7. Evaluation of injuries of the upper cervical spine in a postmortem study with digital radiography, CT and MRI; Evaluation experimentell erzeugter Verletzungen der oberen Halswirbelsaeule mit digitaler Roentgentechnik, Computertomographie und Magnetresonanztomographie

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Herold, T.; Fischer, U.; Grabbe, E. [Goettingen Univ. (Germany). Abt. fuer Roentgendiagnostik; Fadjasch, G.; Saternus, K.S. [Goettingen Univ. (Germany). Abt. fuer Rechtsmedizin; Koebke, J. [Koeln Univ. (Germany). Anatomisches Inst.

    1999-12-01

    obere Halswirbelsaeulen-Praeparate wurden nach definiertem Rotationstrauma sowie nach Praeparation mittels digitaler Roentgentechnik (DIMA Soft P41, Fa. Feinfokus), mittels CT (CTi, High Speed, GE) in konventioneller und in Spiraltechnik (Kollimation 1 mm, Pitch 1.0) sowie mit Hilfe der MRT (Magnetom Vision Siemens) in 2D- und 3D-Technik untersucht. Ergebnisse: Die Praeparation zeigte 6 Wirbelkoerperfrakturen, 5 Densfrakturen, 1 Fraktur des vorderen Atlasbogens, 4 knoecherne Ausrisse an den okzipitalen Kondylen und 6 Laesionen der Ligg. alaria. Die digitale Praeparateradiographie dokumentierte alle Frakturen und die 4 knoechernen Ausrissfrakturen am Condylus occipitalis. In der CT konnten alle Frakturen und ligamentaeren Verletzungen erkannt werden. Die 2D MRT wies 9 Frakturen sicher und 3 fraglich nach; die 3D MRT zeigte 7 Frakturen sicher und 5 fraglich. Von den 4 Ausrissfrakturen konnten 2 mit der 2D MRT und 1 mit der 3D MRT nachgewiesen werden. Ligamentaere Verletzungen waren sicher in der 2D MRT in 2/6 Faellen und in der 3D MRT in 1 Fall zu erkennen. Diskussion: In postmortalen Studien zeigt die CT gegenueber der digitalen Radiographie und der MRT in der Detektion von Frakturen und ligamentaeren Verletzungen der oberen Halswirbelsaeule eine Ueberlegenheit, wobei diese Ergebnisse nur bedingt auf Patienten nach Hochgeschwindigkeitstrauma uebertragbar sind. (orig.)

  8. Staging of multiple myeloma with MRI: comparison to MSCT and conventional radiography; Staging des multiplen Myeloms mit der MRT: Vergleich zur MSCT und zur konventionellen Roentgendiagnostik

    Energy Technology Data Exchange (ETDEWEB)

    Baur-Melnyk, A.; Reiser, M. [Klinikum Grosshadern der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie (Germany)

    2004-09-01

    The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector computed tomography and especially 16- and 64-detector row scanners allow fast imaging with thin slice collimation and multiplanar reconstructions. With low-dose protocols, effective dose reduction can be achieved, so that radiation exposure is only slightly higher than that of a whole-body skeletal x-ray exam. Sensitivity of MSCT is markedly superior to conventional radiography. Due to the direct visualization of the bone marrow with MRI, MRI is superior in detecting early infiltrations with myeloma cells without osteolyses. In advanced multiple myeloma, CT on the other hand, enables for more precise assessment of bony destructions and fracture risk. (orig.) [German] Das Staging von Patienten mit multiplem Myelom erfordert von der Bildgebung eine sensitive Detektion des Befalls im Skelettsystem. Die MRT erlaubt die direkte Darstellung des Knochenmarks, die beim multiplen Myelom 5 verschiedene Signalmuster aufweisen kann: 1. normal erscheinendes Knochenmark bei geringer interstitieller Infiltration, 2. fokaler Befall, 3. diffuser Befall, 4. kombiniert diffuser

  9. Das Bonfils-Intubationsfiberskop im Vergleich mit der direkten Laryngoskopie zur endotrachealen Intubation am simulierten schwierigen Atemweg

    OpenAIRE

    Nemetz, Sebastian Alexander

    2010-01-01

    Die Sicherung der Atemwege ist eine der wichtigsten Aufgaben des mit dem Atemwegsmanagement beauftragten Arztes, da eine fehlgeschlagene Intubation und sich über längere Zeit erstreckende Intubationsversuche schnell zu einer kritischen Hypoxie führen können. Gelingt eine endotracheale Intubation mittels konventioneller Larnygoskopie mit dem Macintosh-Spatel unerwartet nicht, stehen verschiedene supraglottische Atemwegshilfen wie z.B. die Larynxmaske zur Atemwegssicherung zur Verfügung. Falls ...

  10. Resistor dividers on the march; Vorwaerts mit ohmschen Spannungsteilern

    Energy Technology Data Exchange (ETDEWEB)

    Wollschlaeger, P. [Siemens AG, Erlangen (Germany). Bereich Energieuebertragung und -verteilung

    2000-02-07

    Rising costs and the growing scope of functions demanded nowadays of a medium-voltage switchpanel are forcing manufactures to turn to innovative, intelligent solutions. Frequently, customer specifications cannot be costeffectively met with conventional technology; new ground has to be broken. A typical example is the superseding of conventional voltage transformers (with separate cores for protection and measurement) by a voltage sensor with interface to an instrument amplifier. The advantages are clear: Voltage sensors that no longer need to be configured according to network data and purpose of use. It is time for sensorics to find their way into medium voltage equipment; in industrial processes sensors are already long established. (orig.) [German] Steigender Kostendruck bei gleichzeitig zunehmender Funktionalitaet, die heute von einem Mittelspannungsschaltfeld gefordert wird, zwingt den Hersteller zu neuen, intelligenten Loesungen. Zunehmend sind die Kundenwuensche mit konventioneller Technik nicht mehr kostenguenstig zu realisieren, sondern erfordern es, neue Wege zu beschreiten. Ein Beispiel dafuer ist der Ersatz konventioneller Spannungswandler mit getrennten Kernen fuer Schutz und Messung durch einen Spannungssensor mit Schnittstelle zu einem Messverstaerker. Der Vorteil sind Spannungssensoren, die nicht mehr individuell nach Netzdaten und Verwendungszweck projektiert werden muessen. Es wird Zeit, dass die Sensortechnik auch in der Mittelspannung einzieht - in industriellen Prozessen sind Sensoren schon lange im Einsatz. (orig.)

  11. MRT of scaphoid pseudo-arthrosis using Gd-DTPA. Staging and clinical correlation; MRT der Skaphoidpseudarthrose mit Gd-DTPA. Stadieneinteilung und klinische Korrelation

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik; Beutel, F. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik; Wilhelm, K. [LMU Muenchen (Germany). Abt. fuer Handchirurgie; Tempka, A. [Freie Univ. Berlin (Germany). Klinik fuer Unfall- und Wiederherstellungschirurgie; Schedel, H. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik; Haas, R. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik; Felix, R. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik

    1994-11-01

    During a period of two years, 134 patients with pseudo-arthrosis of the scaphoid were examined by conventional radiography and by MRI in the course of a prospective study. The aim of the study was to define radiological staging using contrast enhanced MRI in order to improve the prognostic criteria. All MRI examinations were carried out with a 1.5 Tesla scanner (SP63) using a surface coil and T{sub 1} weighted spin echo sequences in sagittal and frontal projection and frontal FLASH T{sub 2}-sequences and axial spin echo T{sub 2} sequences. The T{sub 1} weighted SE sequences in frontal projection were carried out before and after iv contrast (0.1 mmol Gd-DTPA/kg KG). All sequences were compared with conventional radiographs and the operative findings. Eight patients in stage 0 showed high signal intensity of both fragments in T{sub 1} weighted SE sequences and at surgery there was good vascularisation. In 22 cases there was reduced signal intensity in at least one fragment (stage I). 45 patients with scaphoid pseudo-arthrosis showed complete signal loss but marked contrast uptake with still vital nuclei at surgery (stage II). In 22 patients, there was no increase in signal intensity after contrast and complete loss of vitality of the fragments at surgery. Staging was not possible in 37 patients because of previous operative intervention. The use of contrast enhanced MRI provides additional information compared with conventional radiography or plain MRI. (orig.) [Deutsch] Im Rahmen einer prospektiven Studie wurden in einem Zeitraum von 2 Jahren 134 Patienten mit einer Skaphoidpseudarthrose (SPA) vergleichend konventionell roentgenologisch und magnetresonanztomographisch untersucht. Ziel der Studie war die Erstellung einer klinisch radiologischen Stadieneinteilung mit Hilfe der kontrastverstaerkten MRT zur Verbesserung von Prognosekriterien. Alle MRT-Untersuchungen wurden an einem 1,5 Tesla-Geraet (SP63) mittels einer Oberflaechenspule unter Verwendung von T{sub 1

  12. Mit kokkeri

    DEFF Research Database (Denmark)

    Ejlersen, Søren; Lorang, Louisa

    MIT kokkeri er resultatet af et samarbejde mellem Komiteen for Sundhedsoplysning, Institut for Uddannelse og Pædagogik/Aarhus Universitet og Haver til Maver. Projektet støttes af Nordea-fonden. Bag kogebogens mange opskrifter står en række erfarne madeksperter bestående af Søren Ejlersen, Louisa...

  13. Neutron Radiography

    Science.gov (United States)

    Heller, A. K.; Brenizer, J. S.

    Neutron radiography and its related two-dimensional (2D) neutron imaging techniques have been established as invaluable nondestructive inspection methods and quantitative measurement tools. They have been used in a wide variety of applications ranging from inspection of aircraft engine turbine blades to study of two-phase fluid flow in operating proton exchange membrane fuel cells. Neutron radiography is similar to X-ray radiography in that the method produces a 2D attenuation map of neutron radiation that has penetrated the object being examined. However, the images produced differ and are often complementary due to the differences between X-ray and neutron interaction mechanisms. The uses and types of 2D neutron imaging have expanded over the past 15 years as a result of advances in imaging technology and improvements in neutron generators/sources and computers. Still, high-intensity sources such as those from reactors and spallation neutron sources, together with conventional film radiography, remain the mainstay of high-resolution, large field-of-view neutron imaging. This chapter presents a summary of the history, methods, and related variations of neutron radiography techniques.

  14. Wie sensibel reagieren deutsche Verbraucher auf Preisänderungen bei Bio-Eiern? Eine Nachfrageanalyse mit Haushaltspanel-Daten

    OpenAIRE

    Schroeck, Rebecca

    2011-01-01

    Die Studie analysiert die Nachfrage nach Eiern aus konventioneller und ökologischer Erzeugung in Deutschland auf der Basis von Daten des Haushaltspanels der Gesellschaft für Konsumforschung (GfK) für frische Lebensmittel. Die Datengrundlage ist in ihrer Größe und ihrem Informationsgehalt einzigartig, da sie Einkäufe von mehr als 13.000 Haushalten über einen Fünfjahreszeitraum abbildet. Es wird eine zweistufiges Schätzverfahren angewandt. Im ersten Schritt wird mit einer Probit- Analyse unters...

  15. MR whole spin projection: Computer-based simulation of conventional scoliosis projection; MR-Ganzwirbelsaeulenaufnahme: Computergestuetzte Simulation der konventionell-roentgenologischen Technik

    Energy Technology Data Exchange (ETDEWEB)

    Koenig, R.; Jaeger, U.; Ostertun, B.; Kandyba, J.; Schild, H.H. [Radiologische Universitaetsklinik Bonn (Germany); Wagner, U. [Universitaetsklinik fuer Orthopaedie (Germany); Gieseke, J. [Philips Medizin Systeme (Germany)

    1999-03-01

    , Gesichtsfeld 450 mm) in Kombination mit Pulsoxymeter-gesteuertem Gating. Akquiriert wurden jeweils 64 Schichten in koronarer Schichtfuehrung; die Schichtdicke der aus den 3D-Rohdatensaetzen rekonstruierten koronaren Schichten betrug 2 mm. Es wurde ein PC-basiertes Programm entwickelt, welches die Ergebnisse der beiden Akquisitionen in je einem koronaren und sagittalen Schnittbild zusammenfasste und die Messung des Cobb-Winkels ermoeglichte. Ergebnisse: Die Untersuchungsdauer betrug bei sekundaerer Rekonstruktion der akquirierten Rohdaten im Mittel 14 Minuten pro Patient. Die Bildnachverarbeitung am PC nahm pro Patient sieben Minuten in Anspruch. Bei der Bestimmung der Cobb-Winkel ergab sich eine Standardabweichung von 1,8 Grad. Schlussfolgerung: Die vorgestellten Ergebnisse berechtigen zu der Hoffnung, dass die Frequenz konventioneller Roentgenuntersuchungen bei der Verlaufsbeobachtung der juvenilen Skoliose reduziert werden kann. (orig.)

  16. Micro-radiography and micro-computerized tomography with absorption and phase contrast for materials characterization; Mikro-Radiografie und Mikro-Computertomografie mit Absorptions- und Phasenkontrast fuer die Materialcharakterisierung

    Energy Technology Data Exchange (ETDEWEB)

    Kastner, Johann [FH Oberoesterreich, Wels (Austria)

    2017-08-01

    The contribution describes modern techniques in micro-radiography and micro-computerized tomography for materials characterization using absorption and phase contrast. Using micro- and nano-focus tubes and adequate high.-resolution detectors it is possible to reach resolutions significantly below 1 micron. The CT technology allows in-situ deformation testing to study the damaging mechanism of materials. The application of the Talbot-Lau interferometer with CT a differential phase contrast tomography is available. Dark-field tomography is used to study individual carbon fiber bundles in carbon fiber reinforced laminates.

  17. Kører man forskelligt på en el-cykel og på en konventionel cykel?

    DEFF Research Database (Denmark)

    Møller, Mette

    2014-01-01

    En undersøgelse fra Holland viser, at cyklister kører hurtigere, når de kører på el-cykel, end når de kører på en konventionel cykel. Undersøgelsen viser dog også, at kørehastigheden justeres efter forholdene således, at den højere fart, som el-cyklen giver mulighed for at opnå, primært forekommer...

  18. Kombinierte radiologisch-interventionelle und radiotherapeutische Behandlung von Patienten mit zentralen Gallengangsmalignomen

    Directory of Open Access Journals (Sweden)

    Riedmann E

    2005-01-01

    Full Text Available Einleitung: In einer retrospektiven Analyse von 24 Patienten mit inoperablen oder nicht radikal resezierten Karzinomen des Gallentraktes wurde der Einfluß einer HDR-(high-dose-rate192-Ir-Brachytherapie oder der kombinierten Tele-/Brachytherapie auf Überlebenszeit und Verbesserung der Lebensqualität untersucht. Methode und Material: Von 1996 bis 2001 wurden 24 Patienten mit einem Karzinom, welches die extrahepatischen Gallenwege obstruierte (16 Klatskin-Tumoren, 6 Gallenblasenkarzinome, 2 Metastasen eines GI-Tumors, einer palliativen Radiatio unterzogen. 14 von 24 Patienten wurden bei einem lokal fortgeschrittenen inoperablen Tumor, 5 Patienten nach einer R1-Resektion und 5 Patienten im Rezidiv behandelt. Bei allen Patienten wurde eine perkutane transhepatische Cholangiographie (PTC und anschließend die Implantation eines oder mehrerer selbstexpandierbarer Stents zur Behandlung der biliären Okklusion durchgeführt. 23 Patienten erhielten eine endoluminale Brachytherapie, 10 davon kombiniert mit einer Teletherapie; ein Patient erhielt eine alleinige Teletherapie. Im ersten Jahr wurde sechs Patienten die Brachytherapie mit einer Dosis von 15 Gray (Gy in drei Fraktionen verabreicht. Ab 1997 wurden 17 Patienten mit hyperfraktionierter Brachytherapie (2 x täglich mit einer mittleren Dosis von 20 Gy (5 x 4 Gy behandelt. Die mittlere Dosis der Teletherapie in beiden Gruppen betrug 40 Gy (Range 22–60 Gy. Ergebnisse: Das mediane Überleben für alle Patienten betrug 7,7 Monate. Patienten, die mit hyperfraktionierter Brachytherapie behandelt wurden, zeigten einen Trend zu einem verlängerten Überleben mit 11,6 Monaten verglichen mit 5,7 Monaten in der konventionell behandelten Gruppe. Die akuten Nebenwirkungen waren moderat.

  19. Konstruieren von Pkw-Karosserien: Grundlagen, Elemente und Baugruppen, Vorschriftenübersicht, Beispiele mit CATIA V4 und V5

    Science.gov (United States)

    Grabner, Jörg; Nothhaft, Richard

    Die Faszination, die vom Auto ausgeht, ist und bleibt ungebrochen. Entsprechend interessant ist es, sich vor dem Hintergrund konventioneller Konstruktionstechniken über die virtuelle Produktentwicklung von Pkw-Karosserien an modernen CAD-Arbeitsplätzen informieren zu können. Die Autoren führen in die Grundlagen ein und zeigen anhand von Beispielen und zahlreichen Abbildungen, wie mit dem System CATIA der Rohbau sowie die Ausstattung innen und au=C3=9Fen konstruiert werden. Darüber hinaus wird das so genannte "Package" an Beispielen beschrieben, also das Management und die Harmonisierung der Anforderungen an die Bauräume (z.

  20. Industrial radiographies

    CERN Multimedia

    2005-01-01

    The Radiation Protection group wishes to remind CERN staff responsible for contractors performing X-ray inspections on the CERN sites that the firms must apply the legislation in force in their country of origin, in particular with regard to the prevention of risks relating to ionizing radiation. Industrial radiography firms called on to work on the CERN sites must also comply with the rules laid down in CERN's Radiation Safety Manual and be registered in the relevant CERN database. Since CERN is responsible for safety on its own site, a number of additional rules have been laid down for this kind of work, as set out in Radiation Protection Procedure PRP30 https://edms.cern.ch/file/346848/LAST_RELEASED/PRP30.pdf The CERN Staff Member responsible for the contract shall register the company and issue notification that an X-ray inspection is to be performed via the web interface at the following address: http://cern.ch/rp-radio

  1. Value of conventionally fractionated radiotherapy for the local treatment of HIV associated Kaposi`s sarcoma; Wertigkeit konventionell fraktionierter Radiotherapie bei der lokalen Behandlung des HIV-assoziierten Kaposi-Sarkoms

    Energy Technology Data Exchange (ETDEWEB)

    Saran, F. [Abt. fuer Strahlentherapie und Onkologie, Zentrum der Radiologie, Frankfurt Univ. (Germany); Adamietz, I.A. [Abt. fuer Strahlentherapie und Onkologie, Zentrum der Radiologie, Frankfurt Univ. (Germany); Mose, S. [Abt. fuer Strahlentherapie und Onkologie, Zentrum der Radiologie, Frankfurt Univ. (Germany); Thilmann, C. [Abt. fuer Strahlentherapie und Onkologie, Zentrum der Radiologie, Frankfurt Univ. (Germany); Boettcher, H.D. [Abt. fuer Strahlentherapie und Onkologie, Zentrum der Radiologie, Frankfurt Univ. (Germany)

    1995-10-01

    partielle Remission (PR) (55%), und 12/111 wurden als unveraendert (NC) beurteilt (11%). Die Gesamtansprechrate (CR + PR) betrug 89%. Zwei Patienten mit Laesionen der Mundhoehle zeigten eine Mukositis RTOG Grad IV nach Gesamtdosen von 10 und 14 Gy. Bei 71/106 bestrahlten Laesionen der Haut (67%) wurde eine radiogen induzierte Reaktion ersten Grades (RTOG) gesehen. Durch eine Radiotherapie mit einer Gesamtreferenzdosis von 20 Gy in konventioneller Fraktionierung ist eine Palliation bei HIV-assoziierten Kaposi-Sarkomen moeglich. Der Anteil von Patienten mit kompletter Remission ist jedoch mit 34 bis 47% geringer als im Vergleich zu Gesamtdosen >20 Gy (66 bis 100%). Unsere Ergebnisse unterstuetzen die Vermutung einer dosisabhaengigen Wirkung der Radiotherapie von Kaposi-Sarkomen. Es sollten daher bei Behandlung von HIV-assoziierten Kaposi-Sarkomen in der Radiotherapie Gesamtreferenzdosen von zum Beispiel 30 Gy mit 5mal 2 Gy/Woche bzw. 24 Gy, 5mal 1,6 Gy fuer Schleimhautlaesionen gewaehlt werden, da dadurch die Rate an kompletten Remissionen verdoppelt werden kann. (orig./MG)

  2. International Neutron Radiography Newsletter

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    At the First World Conference on Neutron Radiography i t was decided to continue the "Neutron Radiography Newsletter", published previously by J.P. Barton, as the "International Neutron Radiography Newsletter" (INRNL), with J.C. Doraanus as editor. The British Journal of Non-Destructive Testing...

  3. Increasing mobile radiography productivity.

    Science.gov (United States)

    Wong, Edward; Lung, Ngan Tsz; Ng, Kris; Jeor, Patrick

    2013-01-01

    Mobile radiography using computed radiography (CR) cassettes is a common equipment combination with a workflow bottleneck limited by location of CR readers. Advent of direct digital radiography (DDR) mobile x-ray machines removes this limitation by immediate image review and quality control. Through the use of key performance indicators (KPIs), the increase in efficiency can be quantified.

  4. Assessment of clinical image quality in feline chest radiography with a needle-image plate (NIP) storage phosphor system. An approach to the evaluation of image quality in neonatal radiography; Untersuchungen zur Qualitaet von Thoraxaufnahmen bei Katzen mit einem auf einer Nadelstruktur basierenden Speicherfoliensystem. Modelluntersuchungen zur Bewertung der Bildqualitaet bei Neugeborenen

    Energy Technology Data Exchange (ETDEWEB)

    Ludewig, E.; Bosch, B.; Gaebler, K.; Succow, D.; Werrmann, A. [Klinik fuer Kleintiere, Univ. Leipzig (Germany); Hirsch, W.; Sorge, I. [Abt. Paediatrische Radiologie, Univ. Leipzig (Germany); Gosch, D. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Univ. Leipzig (Germany)

    2010-02-15

    Purpose: Is the image quality of thoracic radiographs of cats obtained with a needle-based storage phosphor (NIP) system superior to conventional (PIP) storage phosphor radiography? Is it possible to decrease the mAs by 50% with the NIP system without significant loss of information? Materials and Methods: From each of the 20 animals, three lateral radiographs were acquired. The assessment of the exposure level was based on the generated IgM-values. Images were acquired 1. with the NIP system and exposure settings equivalent to an IgM of 1.9, 2. with the PIP system and identical settings, and 3. with the NIP system and 50% of the mAs. Six blinded readers used a 5-step scale to assess the reproducibility of five anatomical structures and image noise sensation. Data were analysed using Visual Grading Characteristics Analysis (VGC). Results: While applying identical exposure values the NIP system for all features revealed superior ratings to those of the PIP system (AUC{sub VGC} values ranged from 0.81 for ''cardiac silhouette'' to 0.92 for ''trachea''). Even when reducing mAs by 50% in the NIP images all features were rated better compared with the PIP images and original settings (AUC{sub VGC} values ranged from 0.60 for ''cardiac silhouette'' to 0.74 for ''trachea'' and ''caudal thoracic field''). Conclusion: The NIP system demonstrates clearly better image quality compared to the reference PIP system. A dose reduction of 50% seems to be possible without relevant detraction from image quality. The results obtained in the animal model are valid for simulating conditions in neonatal radiological practise. (orig.)

  5. Wastewater treatment plant Herford with biofiltration; Klaeranlage Herford mit Biofiltration

    Energy Technology Data Exchange (ETDEWEB)

    Altemeier, G. [Herforder Abwasser GmbH, Herford (Germany); Gassen, M.

    1998-09-01

    In order to fulfil the higher effluent requirements especially for nitrogen and phosphorus removal the City of Herford due to limited space at the site of the existing plant planned to construct a new wastewater treatment plant applying the activated sludge process at a location in 4 km distance. During the environmental impact study it was decided to construct at the existing site a completely covered wastewater treatment plant (from screen to post floculation). Biological treatment is achieved by a less space consuming biofiltration plant (Biostyr process). The costs remained in the same range as of conventional plants. (orig.) [Deutsch] Um den gestiegenen Anforderungen insbesondere zur Stickstoff- und Phosphorelimination nachzukommen, plante die Stadt Herford wegen unzureichender Flaeche bei der vorhandenen Klaeranlage urspruenglich einen Neubau der Klaeranlage nach dem Belebungsverfahren an einem 4 km entfernten Standort. Im Zuge der Umweltvertraeglichkeitsuntersuchung kam man zu dem Entschluss, am vorhandenen Standort eine komplett eingehauste Abwasserreinigungsanlage (vom Rechen bis zur Nachflockung) zu errichten. Die biologische Reinigung erfolgt mit einer wenig Platz beanspruchenden Biofilteranlage (Biostyr Verfahren). Die Kosten blieben im Rahmen vergleichbarer konventioneller Anlagen. (orig.)

  6. Electrical machines, in particular generators: superconductor technology in competition with improved conventional technology; Elektrische Maschinen, insbesondere Generatoren: Supraleiter-Technologie im Wettbewerb mit verbesserter konventioneller Technologie

    Energy Technology Data Exchange (ETDEWEB)

    Joho, R.; Ginet, C.; Schleussinger, A.

    2006-07-01

    This final report for the Swiss Federal Office of Energy (SFOE) summarises work done within the framework of a second project on the use of superconductor technology and conventional technology in electrical machines. The two variants, a generator using second-generation high-temperature superconductors (HTSC) and one using improved conventional technology are described and compared. The use of various coolants for the windings of generators of various types and usage is described and the optimisation of winding-geometry is discussed. The refrigeration equipment used to provide low-temperature coolant is looked at and the energy balance for the combination of generator and cooling system is discussed. The conclusions drawn by the project are presented and the advantages offered by both variants are discussed.

  7. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Vejle-Sørensen, Jens Kristian; Thomsen, Henrik;

    2015-01-01

    of clinical supervisors. Optimal collimation is determined by European and Regional Danish guidelines. The areal between current and optimal collimation is calculated. The experimental research is performed in September - October 2014 Siemens Axiom Aristos digital radiography system DR using 150 kV, 1,25 -3......Purpose: Quality improvement of basic radiography focusing on collimation and dose reduction in digital chest radiography Methods and Materials:A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from...... one hundred fifty self-reliant female patients between 15 and 55 years of age are included in the study. The clinical research is performed between September and November 2014 where 3rd year Radiography students collect data on four Danish x-ray departments using identical procedures under guidance...

  8. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    2015-01-01

    Background: Chest radiography is one of the most common examinations in radiology departments. In 2013 approximately 80,000 chest x-rays were performed on women in the fertile age. Even low dose for the examinationCorrect collimation Purpose: Quality improvement of basic radiography focusing...... collimations depending on side of radiograph. Results from dose reduction will be presented on the congress Conclusion: Correct positioning and collimation of digital chest radiographs can reduce the radiation dose significant to the patients and by that improve the quality of basic radiography....... on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...

  9. Differentialtherapie mit Kalziumantagonisten

    Directory of Open Access Journals (Sweden)

    Dörffel Y

    2004-01-01

    Full Text Available Der antihypertensive Effekt der Kalziumantagonisten ist bei allen Altersgruppen und Rassen seit längerem erwiesen. Darüber hinaus sind verschiedene andere positive Wirkungen dokumentiert, wie z. B. die Verbesserung der Endothelfunktion, Reduktion der Atheroskleroseprogression in der A. carotis, Reduktion der linksventrikulären und der arteriolären Hypertrophie sowie eine Verbesserung der arteriellen Compliance. Kalziumantagonisten verschlechtern nicht den Lipid- oder Glukosestoffwechsel. Für den Einsatz in der Praxis ist die Kenntnis der Heterogenität der Substanzklasse mit sich daraus ableitenden Vor- und Nachteilen sowie unterschiedlichen Indikationen von großer Relevanz. Den Prototypen der Non-Dihydropyridine Verapamil (chem. Phenylalkylamin und Diltiazem (chem. Benzothiazepine steht die umfangreiche Substanzklasse der Dihydropyridine (DHP gegenüber. Zu den DHPs zählen neben dem Prototyp Nifedipin die neueren Substanzen wie Nitrendipin, Nisoldipin, Amlodipin, Felodipin, Lacidipin und Lercanidipin. DHPs sind in erster Linie Vasodilatatoren, die durch eine Reduktion des peripheren vaskulären Widerstandes den arteriellen Blutdruck senken. Insbesondere bei älteren Präparaten mit schnellem Wirkungseintritt, wie z. B. beim unretardierten Nifedipin, einem DHP der ersten Generation, kann eine autonome Gegenregulation ausgelöst werden. Bei den modernen DHPs mit längerer Wirkungsdauer und bei den Non-DHPs ist dieser Effekt bedeutend abgeschwächt oder gar nicht mehr nachweisbar. In mehreren prospektiven, randomisierten und placebokontrollierten Studien konnte bei Patienten mit isolierter systolischer Hypertonie eine Reduktion der Schlaganfallrate dokumentiert werden (Syst-Eur, Syst-China, signifikante Unterschiede bezüglich Mortalität und Morbidität ergaben sich im Vergleich mit anderen Antihypertensiva (Diuretika, Betablocker, ACE-Hemmer nicht (STOP-2, INSIGHT, NORDIL, ALLHAT, INVEST. In der meist erforderlichen antihypertensiven

  10. MR enteroclysis for MR diagnosis of inflammatory small bowel disease with contrast enhancement; MR-Enteroklyse zur kernspintomographischen Diagnostik entzuendlicher Darmerkrankungen mit verbesserter Darmkontrastierung

    Energy Technology Data Exchange (ETDEWEB)

    Aschoff, A.J.; Zeitler, H.; Merkle, E.M.; Brambs, H.J.; Rieber, A. [Universitaetsklinikum Ulm (Germany). Abt. fuer Radiologische Diagnostik; Reinshagen, M. [Universitaetsklinikum Ulm (Germany). Abt. fuer Innere Medizin

    1997-10-01

    Purpose: To evaluate MRI for effectiveness in assessment of intra- und extramural changes in the small intestine. Methods: 40 patients with known or suspected small bowel disease underwent MR imaging immediately after conventional enteroclysis with barium and a mixture of methyl cellulose and gadolinium-DTPA. Results: In 6 of 24 patients with no pathological findings in conventional enteroclysis, intraabdominal pathology such as thickening of the intestinal wall and an abscess were identified. In the remaining patients, MRI showed good correlation with conventionally obtained data and provided important additional information regarding extraluminal involvement such as enlargement of mesenterial lymph nodes and fistulas as well as abscesses. Conclusions: MRI, carried out using this technique, provides important additional information regarding intra- and extraluminal changes with good image quality. (orig.) [Deutsch] Ziel: Beurteilung der Effektivitaet der Kombination aus Magnetresonanztomographie und konventioneller Enteroklyse nach Sellink in der Duenndarmdiagnostik entzuendlicher Darmerkrankungen. Material und Methode: 40 Patienten mit bekanntem oder vermutetetem M. Crohn wurden direkt im Anschluss an eine Duenndarmenteroklyse mit Barium und einer Mischung aus Tylose und einem oralen gadoliniumhaltigen Kontrastmittel kernspintomographisch untersucht. Ergebnisse: Bei 6 von 24 Patienten mit unauffaelligem konventionellen Sellink zeigte die MRT pathologische Befunde wie Darmwandverdickungen und einen Abszess. Bei den uebrigen Patienten entsprachen die MR-Befunde den konventionell erhobenen. Zusaetzlich ergaben sich weitere Aspekte in bezug auf die extraluminale Beteiligung und das Ausmass der Erkankung wie drei interenterische Fisteln und zwei Abszesse sowie das Vorhandensein vergroesserter mesenterialer Lymphknoten. Schlussfolgerung: Die MRT bietet, wenn sie in der hier beschriebenen Technik durchgefuehrt wird, wichtige und zusaetzliche Informationen ueber intra

  11. Coating mit Biopolymeren

    Science.gov (United States)

    Kumpugdee-Vollrath, Mont; Nunthanid, Jurairat; Sriamornsak, Pornsak

    Biopolymere sind Polymere, die in der Natur vorkommen bzw. mit einigen Prozessen weiter bearbeitet werden, sodass sie für bestimmte Zwecke eingesetzt werden können. Häufig sind sie durch ihre Bioabbaubarkeit, Biokompatibilität und nicht vorhandene bzw. geringe Toxizität von Interesse für den Einsatz in der Medizin bzw. Pharmazie.

  12. Radiography at CERN

    CERN Document Server

    HSE Unit

    2014-01-01

    What is industrial radiography? It is a non-destructive method with a wide variety of applications, such as inspecting the quality of a weld. It uses high-energy radioactive sources or an X-ray generator.   Is this inspection technique used at CERN? Yes, it is widely used at CERN by the EN-MME Group, which outsources the work to one or more companies, depending on the workload. Is it possible to carry out radiography anywhere at CERN? Yes, it is possible to carry out radiography in any building/accelerator/experiment area at CERN (including in areas which are not normally subject to radiological hazards). When is radiography carried out? It normally takes place outside of working hours (7 p.m. to 6 a.m.). How will I know if radiography is taking place in my building? If this activity is planned in a CERN building, notices will be affixed to all of its main entrance doors at least 24 hours in advance. What are the risks? There is a risk of exposure to very high levels of radiation, dep...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) ... diagnosis and disease management. top of page How is the procedure performed? The technologist, an individual specially ...

  14. Real-time radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bossi, R.H.; Oien, C.T.

    1981-02-26

    Real-time radiography is used for imaging both dynamic events and static objects. Fluorescent screens play an important role in converting radiation to light, which is then observed directly or intensified and detected. The radiographic parameters for real-time radiography are similar to conventional film radiography with special emphasis on statistics and magnification. Direct-viewing fluoroscopy uses the human eye as a detector of fluorescent screen light or the light from an intensifier. Remote-viewing systems replace the human observer with a television camera. The remote-viewing systems have many advantages over the direct-viewing conditions such as safety, image enhancement, and the capability to produce permanent records. This report reviews real-time imaging system parameters and components.

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  16. Artifacts in digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Whan [Dept. of Radiological Technology, Shin Gu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Technology, Korea University, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Beakseok Culture University, Cheonan (Korea, Republic of)

    2015-12-15

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments.

  17. Quantitative film radiography

    Energy Technology Data Exchange (ETDEWEB)

    Devine, G.; Dobie, D.; Fugina, J.; Hernandez, J.; Logan, C.; Mohr, P.; Moss, R.; Schumacher, B.; Updike, E.; Weirup, D.

    1991-02-26

    We have developed a system of quantitative radiography in order to produce quantitative images displaying homogeneity of parts. The materials that we characterize are synthetic composites and may contain important subtle density variations not discernible by examining a raw film x-radiograph. In order to quantitatively interpret film radiographs, it is necessary to digitize, interpret, and display the images. Our integrated system of quantitative radiography displays accurate, high-resolution pseudo-color images in units of density. We characterize approximately 10,000 parts per year in hundreds of different configurations and compositions with this system. This report discusses: the method; film processor monitoring and control; verifying film and processor performance; and correction of scatter effects.

  18. CCD digital radiography system

    Science.gov (United States)

    Wang, Yi; Kang, Xi; Li, Yuanjing; Cheng, Jianping; Hou, Yafei; Han, Haiwei

    2009-07-01

    Amorphous silicon flat-panel detector is the mainstream used in digital radiography (DR) system. In latest years, scintillation screen coupled with CCD DR is becoming more popular in hospital. Compared with traditional amorphous silicon DR, CCD-DR has better spatial resolution and has little radiation damage. It is inexpensive and can be operated easily. In this paper, A kind of CCD based DR system is developed. We describe the construction of the system, the system performances and experiment results.

  19. Radiography with polarised neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Michael L.

    2010-08-20

    In this thesis I present a new technique for the spatially resolved investigation of the magnetic properties of bulk samples. Standard one dimensional neutron depolarisation analysis is combined with neutron radiography to a method we call Neutron Depolarisation Imaging (NDI). The experimental setup which was installed at the neutron radiography beam line ANTARES at FRM II consists of a double crystal monochromator, neutron polariser, spin flipper, polarisation analyser and a position sensitive CCD detector. A comprehensive discussion of the requirements for these components is given and the limitations of the method are shown. The maximum spatial resolution which can be achieved with a neutron radiography setup is determined by the collimation of the neutron beam and the distance between sample and detector. Different types of polarisers have been tested and their advantages and disadvantages are discussed. A double crystal monochromator and a new type of polariser employing polarising neutron supermirrors based on the principle of an optical periscope were developed and tested during this work. Furthermore, NDI measurements on various samples of the weakly ferromagnetic materials Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al are presented. Neutron depolarisation radiography and tomography measurements were conducted with a spatial resolution as high as 0.3 mm on Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al samples. The feasibility of NDI experiments under hydrostatic pressures up to 10 kbar was shown on a sample of Ni{sub 3}Al using a modified Cu:Be clamp cell. A decrease of the ordering temperature by 2 K under hydrostatic pressure was determined from the NDI measurements and shows the potential of the method for further high pressure experiments. Additionally a method was developed which in principle allows to obtain the intrinsic dependence of the ordering temperature T{sub C} on the ordered moment Ms from NDI measurements on inhomogeneous samples containing regions with

  20. MIT-CSR XIS Project

    Science.gov (United States)

    1998-01-01

    This report outlines the proposers' progress toward MIT's contribution to the X-Ray Imaging Spectrometer (XIS) experiment on the Japanese ASTRO-E mission. The report discusses electrical system design, mechanical system design, and ground support equipment.

  1. Die Last mit der Lust

    Directory of Open Access Journals (Sweden)

    Lutz Sauerteig

    2004-03-01

    Full Text Available Robert Jütte legt mit Lust ohne Last eine umfassende, allgemeinverständliche und spannend zu lesende Geschichte der Empfängnisverhütung von der Antike bis in die unmittelbare Gegenwart vor.

  2. Kleben von Kunststoff mit Metall

    CERN Document Server

    Brockmann, W; Käufer, H

    1989-01-01

    Das Buch behandelt das Kleben von Kunststoffen mit Metallen in einer fur den Praktiker verstandlichen und umsetzbaren Form. Es leitet zu Klebeverfahren an, die optimale Ergebnisse hinsichtlich Qualitat, Dauerhaftigkeit und Wirtschaftlichkeit liefern.

  3. Spillerum og mit eget rum

    DEFF Research Database (Denmark)

    2014-01-01

    Undervisningsmaterialet Spillerum udviklet som APP til Ipad med interaktive muligheder. Spillerum som APP - et interaktivt undervisningsmateriale, hvor man ud over at bruge det originale materiale Spillerum elektronisk kan skabe sit eget billedbaserede rum "Mit eget rum" som udgangspunkt for dialog....

  4. MIT Lincoln Laboratory Facts 2013

    Science.gov (United States)

    2012-12-01

    6 years old. Technology Children’s Centers are managed by Bright Horizons and overseen by the MIT Center for Work, Family & Personal Life. Health...service-disabled veteran-owned small business, HUBZone small business, small disadvantaged business, and woman- owned small business concerns, as well...MIT $13,780 Raised for the Multiple Sclerosis Society in the Bike & Hike the Berkshires fundraiser $23,600 Raised at the annual Alzheimer’s

  5. Verbalsuffixe mit Liquida

    Directory of Open Access Journals (Sweden)

    Marina Zorman

    1995-12-01

    Full Text Available Der vorliegende Beitrag stellt eine Zusammenfassung bzw. vervollständigte Ver­ sion einiger Kapitel der Magisterarbeit der Autorin mit dem Titel Expressive Wort­ bildung beim Verb (Ältere, wahrscheinlich ererbte Kombinationen -V/C- + -r/l- - das Grundtypus -dr- - im Slowenischen dar. Die wesentlichen Erkenntnisse der Arbeit hinsichtlich der morphologischen und semantischen Gestalt derartiger Verben, ihrer dialektologischen Verbreitung und der Genese, Funktion und Austauschbarkeit dieser Suffixe sollen unter dem Titel "Ekspresivne glagolske pripone tipa -V/C + -r/l-" in den "Razprave XV II. razreda SAZU" (Dissertationes Classis II, XV. Ljubljana, Academia scientiarium et artium Slovenica (in Druck veröffentlicht werden, deshalb werden sie hier nur so weit aufgenommen, wie das für das Verständnis des behandelten Gegen­ stands unbedingt notwendig ist. Eingehender werden Fragen erortert, die im erwähnten Artikel nicht behandelt werden, die jedoch auch für andere Linguisten interessant sein könnten. So ist der vorliegende Beitrag in vier Teile gegliedert

  6. Scatter in cargo radiography.

    Science.gov (United States)

    Miller, Erin A; Caggiano, Joseph A; Runkle, Robert C; White, Timothy A; Bevill, Aaron M

    2011-03-01

    As a complement to passive detection systems, radiographic inspection of cargo is an increasingly important tool for homeland security because it has the potential to detect highly attenuating objects associated with special nuclear material or surrounding shielding, in addition to screening for items such as drugs or contraband. Radiographic detection of such threat objects relies on high image contrast between regions of different density and atomic number (Z). Threat detection is affected by scatter of the interrogating beam in the cargo, the radiographic system itself, and the surrounding environment, which degrades image contrast. Here, we estimate the extent to which scatter plays a role in radiographic imaging of cargo containers. Stochastic transport simulations were performed to determine the details of the radiography equipment and surrounding environment, which are important in reproducing measured data and to investigate scatter magnitudes for typical cargo. We find that scatter plays a stronger role in cargo radiography than in typical medical imaging scenarios, even for low-density cargo, with scatter-to-primary ratios ranging from 0.14 for very low density cargo, to between 0.20 and 0.40 for typical cargo, and higher yet for dense cargo.

  7. MIT's interferometer CST testbed

    Science.gov (United States)

    Hyde, Tupper; Kim, Ed; Anderson, Eric; Blackwood, Gary; Lublin, Leonard

    1990-12-01

    The MIT Space Engineering Research Center (SERC) has developed a controlled structures technology (CST) testbed based on one design for a space-based optical interferometer. The role of the testbed is to provide a versatile platform for experimental investigation and discovery of CST approaches. In particular, it will serve as the focus for experimental verification of CSI methodologies and control strategies at SERC. The testbed program has an emphasis on experimental CST--incorporating a broad suite of actuators and sensors, active struts, system identification, passive damping, active mirror mounts, and precision component characterization. The SERC testbed represents a one-tenth scaled version of an optical interferometer concept based on an inherently rigid tetrahedral configuration with collecting apertures on one face. The testbed consists of six 3.5 meter long truss legs joined at four vertices and is suspended with attachment points at three vertices. Each aluminum leg has a 0.2 m by 0.2 m by 0.25 m triangular cross-section. The structure has a first flexible mode at 31 Hz and has over 50 global modes below 200 Hz. The stiff tetrahedral design differs from similar testbeds (such as the JPL Phase B) in that the structural topology is closed. The tetrahedral design minimizes structural deflections at the vertices (site of optical components for maximum baseline) resulting in reduced stroke requirements for isolation and pointing of optics. Typical total light path length stability goals are on the order of lambda/20, with a wavelength of light, lambda, of roughly 500 nanometers. It is expected that active structural control will be necessary to achieve this goal in the presence of disturbances.

  8. Radiography students' clinical learning styles.

    Science.gov (United States)

    Ward, Patti; Makela, Carole

    2010-01-01

    To examine the common learning styles of radiography students during clinical practice. Descriptive research methodology, using a single self-report questionnaire, helped to identify common learning styles of radiography students during clinical practice. The results indicated that 3 learning styles predominate among radiography students during clinical practice: task oriented, purposeful and tentative. Insight into clinical practice learning styles can help students understand how they learn and allow them to recognize ways to maximize learning. It also heightens awareness among clinical instructors and technologists of the different learning styles and their relevance to clinical practice education.

  9. Euratom Neutron Radiography Working Group

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    In 1979 a Neutron Radiography Working Group (NRWG) was constituted within Buratom with the participation of all centers within the European Community at which neutron facilities were available. The main purpose of NRWG was to standardize methods and procedures used in neutron radiography of nuclear...... reactor fuel as well as establish standards for radiographic image quality of neutron radiographs. The NRWG meets once a year in each of the neutron radiography centers to review the progress made and draw plans for the future. Besides, ad-hoc sub-groups or. different topics within the field of neutron...... radiography are constituted. This paper reviews the activities and achievements of the NRWG and its sub-groups....

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses ... assess trauma patients in emergency departments. A CT scan can image complicated fractures, subtle fractures or dislocations. ...

  11. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very small dose ... to produce pictures of the inside of the abdominal cavity. It is used to evaluate the stomach, liver, ...

  12. Proton Radiography (pRad)

    Data.gov (United States)

    Federal Laboratory Consortium — The proton radiography project has used 800 MeV protons provided by the LANSCE accelerator facility at LANL, to diagnose more than 300 dynamic experiments in support...

  13. Robotisches Elektromobil mit kamerabasiertem Autonomieansatz

    OpenAIRE

    2011-01-01

    Autonomes Fahren erfährt in den vergangenen Jahren durch verschiedene Forschungsprojekte ein gesteigertes öffentliches Interesse. Dabei werden meist herkömmliche Pkw mit großem Aufwand umgebaut und mit Dachaufbauten voller Sensorik bestückt. Der Vormarsch der Elektromobilität bietet die Chance für grundlegend neue Fahrzeugkonzepte. Löst man sich von klassischen Ansätzen, so ist es möglich, die Autonomie von Anfang an in die Automobilarchitektur hinsichtlich IT- und Sensor-Systemen, Energieman...

  14. MIT January Operational Internship Experience

    Science.gov (United States)

    Bosanac, Natasha; DeVivero, Charlie; James, Jillian; Perez-Martinez, Carla; Pino, Wendy; Wang, Andrew; Willett, Ezekiel; Williams, Kwami

    2010-01-01

    This viewgraph presentation describes the MIT January Operational Internship Experience (JOIE) program. The topics include: 1) Landing and Recovery; 2) Transportation; 3) Shuttle Processing; 4) Constellation Processing; 5) External Tank; 6) Launch Pad; 7) Ground Operations; 8) Hypergolic Propellants; 9) Environmental; 10) Logistics; 11) Six Sigma; 12) Systems Engineering; and 13) Human Factors.

  15. Upper Gastrointestinal (GI) Tract X-Ray (Radiography)

    Science.gov (United States)

    ... Site Index A-Z X-ray (Radiography) - Upper GI Tract Upper gastrointestinal tract radiography or upper GI ... GI) Tract X-ray? What is Upper Gastrointestinal (GI) Tract Radiography? Upper gastrointestinal tract radiography, also called ...

  16. Lower Gastrointestinal (GI) Tract X-Ray (Radiography)

    Science.gov (United States)

    ... Site Index A-Z X-ray (Radiography) - Lower GI Tract Lower gastrointestinal tract radiography or lower GI ... of Lower GI Tract Radiography? What is Lower GI Tract X-ray Radiography (Barium Enema)? Lower gastrointestinal ( ...

  17. Use of fluorescent screens for isotope radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hubbard, S. K.

    1979-01-01

    Radiographic examination can be performed on items beyond the limitation of conventional isotope radiography without a great loss of resolution. With proper film and screen selection and scatter radiation control, fluorescent screens can be a valuable additional tool for radiography.

  18. Peripheral dose from neutrons and photons in the radiation treatment of pelvic tumors with conventional technique or VMAT. A review; Periphere Neutronen- und Photonendosis bei der Radiotherapie von Tumoren des Beckens mit konventioneller Technik oder VMAT. Eine Literaturuebersicht

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, P. [Medizinische Univ. Graz (Austria). Comprehensive Cancer Center

    2015-07-01

    Peripheral neutron and photon doses from external beam radiation therapy are associated with the risk of carcinogenesis in organs distant to the treated volume. In the irradiation of tumors and target volumes in the pelvis with convention photon-radiotherapy beams with high nominal energies (above 15 MeV) are typically used. During the last years volumetric modulated arc therapy (VMAT) techniques have gained a wide-spread use for pelvic treatments. The beam-energies that are primarily used in VMAT are below 10 MeV. Therefore, a reduction in peripheral dose due to the absence of neutrons can be expected when VMAT is utilized. On the other hand the number of monitor units is increased in increased in VMAT, as compared to conventional unmodulated fields, by a factor of two to three. This leads to an increase in transmission dose from the machine's treatment head, such that the potential benefit might be outbalanced. The question, whether the increasing use of VMAT might lead to a reduction of peripheral dose, is the subject of several studies. Those studies use either measurements in phantom settings or Monte-Carlo simulations. A systematic review of the literature shows diverging, and sometimes even contradictory, findings. Therefore, the issue of peripheral dose and the risk for secondary malignancies requires further investigation. In our opinion, the focus should be put on measurements and simulations, but also on modelling of dose-response correlations.

  19. Comparison of conventional full spine radiographs and fluoroscopic scanning method in young patients with idiopathic scoliosis; Vergleich von konventioneller Wirbelsaeulenganzaufnahme und fluoroskopischer Scan-Methode bei jungen Patienten mit idiopathischer Skoliose

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, J.; Kottke, R.; Claussen, C. [Abt. fuer Radiologische Diagnostik, Universitaetsklinikum Tuebingen (Germany); Kluba, T.; Niemeyer, T.; Hahnfeldt, T. [Klinik und Poliklinik fuer Orthopaedie, Universitaetsklinikum Tuebingen (Germany); Vonthein, R. [Inst. fuer Medizinische Biometrie, Universitaetsklinikum Tuebingen (Germany); Kamm, K.F. [Philips Medizin Systeme GmbH, Hamburg (Germany)

    2005-08-01

    Purpose: evaluation of low-dose full spine radiographs using fluoroscopic images for the assessment of the Cobb angle measurement in patients with scoliosis. Material and methods: twenty-one consecutive patients (aged 10-27 years, mean age 14 years) with a conventional full spine examination (film speed class 800) underwent a follow-up exam using digital pulsed fluoroscopy (Multi Diagnost 4, Philips Medical Systems, Eindhoven, The Netherlands). The mean follow-up was 9 months. During a synchronized scan with a C-arm speed of 4 cm/sec fluoroscopic images were stored with a pulsed frequency of 3 images per second. The single images were merged and reconstructed to one image with the software easy spine (Philips medical Systems, Eindhoven, The Netherlands). The corresponding dose-area product values (DAP) of both methods were compared. Three independent observers assessed Cobb angles and image quality for each technique. Results: the mean DAP values for conventional imaging was 94.9 cGy x cm{sup 2} and for fluoroscopy 7.8 cGy x cm{sup 2}, respectively. A significant dose reduction of 91.8% (CI 91% to 95%) was calculated. The average absolute angle difference between the observers was found to be 2.7 for conventional imaging and 2.4 for the fluoroscopic method. Interobserver standard deviation of 2.9 was lower than the 5.3 for conventional images. Image quality was better in the conventional images. Conclusion: using the scanning method, we could achieve a mean reduction of the radiation dose of 92%, while the accuracy of the Cobb angle measurements was comparable for both techniques despite of reduced image quality of digital fluoroscopy. (orig.)

  20. Mit der Technik auf du

    OpenAIRE

    Gleitsmann, Rolf-Jürgen; Kunze, Rolf-Ulrich

    2017-01-01

    Im Vordergrund auch dieses dritten Bandes mit Technikessays steht die Bildinterpretation und die Erschließung von Bildquellen für die kontextualisierende, sozialkonstruktivistische Kulturgeschichte der Technik, die bislang noch wenig oder gar nicht Gegenstand historischer Betrachtung waren: u. a. der Graphiken von Carl G. Evers aus den 1950er Jahren, amerikanischer und deutscher Modellbahnzeitschriften, von Industriewerbung und einem Verkehrsbilderbuch. Zeitlich liegt der Schwerpunkt auf der ...

  1. Mit Rechten am rechten Ort?

    OpenAIRE

    Bräuß, Katharina

    2010-01-01

    Kann pädagogisch sinnvoll mit rechtsextremen Jugendlichen in einer Gedenkstätte für die Opfer des Nationalsozialismus gearbeitet werden? Diese Frage steht im Zentrum der vorliegenden Arbeit, die sich im interdisziplinären Feld von Erinnerungs- und Gedenkstättenpädagogik, Rechtsextremismusforschung und pädagogischer Intervention/Prävention gegenüber Rassismus und Rechtsextremismus bewegt.

  2. MIT Lincoln Laboratory Facts 2015

    Science.gov (United States)

    2015-01-01

    either middle- or high- school students. These programs are aimed at encouraging students, particularly in underserved populations , to pursue...useful information to fellow employees who are experiencing the significant impact Alzheimer’s disease has on indi- viduals and families . They also...support educational programs and Community Giving at MIT $7420 Raised for the Multiple Sclerosis Society in the Bike & Hike the Berkshires

  3. Radiography in construction and combination of other NDT methods; Radiografie im Bauwesen und Kombination anderer ZfP-Verfahren

    Energy Technology Data Exchange (ETDEWEB)

    Hasenstab, Andreas [Ingenieurbuero Dr. Hasenstab GmbH, Augsburg (Germany); Redmer, B. [Bundesanstalt fuer Materialforschung- und pruefung (BAM), Berlin (Germany)

    2016-05-01

    Radiography is in material examination one of the important research methods. So in the steel and plant construction a variety of studies are carried out. In construction, the dominance is the investigations with radar, ultrasonic echo and so in this contribution especially applications with radiographic methods are discribed. Furthermore the combination with different NDT methods should be presented. In all examples there was a combination of radiography and other non-destructive testing methods. In the first example, there is a combination of radiography with ultrasound echo and drilling resistance to an old oak beam from the St. Mary´s church in Lutherstadt Wittenberg (Germany). Measurements by reinforcement locating and radiography of steel plates in the vault of castle Lustheim near Munich and studies using radar and radiography at a temple in the Pergamon Museum in Berlin round off the examples. [German] Die Radiografie stellt in der Materialuntersuchung eine der bedeutendsten Untersuchungsmethoden dar. So werden im Stahl- und Anlagenbau eine Vielzahl von Untersuchungen durchgefuehrt. Im Bauwesen liegt die Dominanz der Untersuchungen bei den Verfahren Radar, Ultraschallecho und so sollen im folgenden Beitrag vor allem Anwendungsbeispiele mit radiographischen Methoden beschrieben werden. Weiter soll die Kombination unterschiedlicher ZfP-Verfahren dargestellt werden. Bei allen Beispielen kam es zu einer Kombination von Radiografie mit anderen zerstoerungsfreien Pruefverfahren. Im ersten Beispiel kommt es zu einer Kombination von Radiografie mit Ultraschallecho und Bohrwiderstand an einem alten Eichenbalken aus der Marienkirche aus Lutherstadt Wittenberg. Messungen mittels Bewehrungsortung und Radiografie an Stahllaschen im Gewoelbe des Schlosses Lustheim bei Muenchen und Untersuchungen mittels Radar und Radiografie an einem Tempel im Pergamonmuseum in Berlin runden die Beispiele ab.

  4. Practical application of suspension criteria scenarios in general radiography, computed radiography,digital radiography and fluoroscopy.

    Science.gov (United States)

    O'Connor, U; Gallagher, A; O'Reilly, G; Dowling, A; Malone, J F

    2013-02-01

    Radiological equipment must be assessed against criteria for acceptability to ensure that it meets the minimum standards for patient safety. This assessment is typically led by a medical physicist with input from radiology staff and the equipment supplier. Equipment that does not meet the criteria requires action and may be suspended from clinical use. European Commission report RP 91 will be revised and replaced as RP 162. It has been drawn up to aid medical physicists with the assessment process and provide guidance on suspension levels. This paper details several cases where the criteria in the proposed RP 162 were applied in general radiography, computed radiography, digital radiography and fluoroscopy. The factors considered by the medical physicist and the outcome of each case are presented. The proposed RP 162 report improves on its predecessor and provides a robust set of criteria for ensuring that patient safety within the EU medical exposures framework is optimised.

  5. Diskriminierung von Enantiomeren mit chiralen Selektoren

    OpenAIRE

    Würthner, Stefan

    2007-01-01

    Die vorliegende Dissertation befasst sich mit der systematischen Aufklärung von zwischenmolekularen Wirt-Gast-Wechselwirkungen von Arzneistoffen mit Cyclodextrinen. In einem sich trichterförmig verengenden Erkenntnisprozeß wird im ersten Schritt eine breite Datenbasis von Kapillarelektrophorese-Daten von 86 chiralen Arzneistoffen mit 3 nativen CDs (alpha, beta und gamma) sowie 11 CD-Derivaten gewonnen. Sowohl die Trennfaktoren der Enantiomeren (alpha_m) als auch die Retardierungsfaktoren (R_m...

  6. Image quality and exposure dose in digital projection radiography; Bildqualitaet und Dosis in der Digitalen Projektionsradiographie

    Energy Technology Data Exchange (ETDEWEB)

    Busch, H.P.; Busch, S.; Decker, C.; Schilz, C. [Krankenhaus der Barmherzigen Brueder Trier, Abt. fuer Radiologie, Trier (Germany)

    2003-01-01

    Purpose: Comparison of the imaging capabilities of storage phosphor (computed) radiography and flat plate radiography with conventional film-screen radiography to find new strategies for quality and dose management, i.e., optimizing imaging quality and dose depending on the imaging method and clinical situation. Materials and Methods: Images of a CDRAD-phantom, hand-phantom, abdomen-phantom and chest-phantom obtained with different exposure voltages (50 kV, 73 kV, 109 kV) and different speeds (200, 400, 800, 1600) were processed with various digital systems (flat plate detector: Digital Diagnost [Philips]; storage phosphors: ADC-70 [Agfa], ADC-Solo [Agfa], FCR XG 1 [Fuji]) and a conventional film-screen system (HT100G/Ortho Regular [Agfa]). Results: The evaluation of CDRAD images found the flat plate detector system to have the highest contrast detectability for all dose levels, followed by the FCR XG 1, ADC-Solo and ADC-70 systems. Comparison of the organ-phantom images found the flat plate detector system to be equal to film-screen radiography and especially to storage phosphor systems even for low exposure doses. Conclusions: Flat plate radiography systems demonstrate the highest potential for high image quality when reducing the exposure dose. Depending on the system generation, the storage phosphor systems also show an improved image quality, but the possibility of a dose reduction is limited in comparison with the flat plate detector system. (orig.) [German] Ziel: Die vergleichende Darstellung der Abbildungseigenschaften verschiedener Speicherfoliengeraete und einer Flachdetektoranlage mit Film/Folienaufnahmen kann zu neuen Strategien des Qualitaets- und Dosismanagements fuehren, d.h. zu einer Optimierung von Bildqualitaet und Dosis in Abhaengigkeit von der Untersuchungsmethode und der klinischen Fragestellung. Methode: Aufnahmen von einem CDRAD-Phantom, Handphantom, Abdomenphantom und Thoraxphantom wurden mit verschiedenen digitalen Systemen (Flachdetektor

  7. Fracture healing: direct magnification versus conventional radiography

    Energy Technology Data Exchange (ETDEWEB)

    Link, T.M. [Dept. of Clinical Radiology, Westfaelische Wilhelms-Univ., Muenster (Germany); Kessler, T. [Dept. of Traumatic and Hand Surgery, Westfaelische Wilhelms-Univ., Muenster (Germany); Lange, T. [Dept. of Clinical Radiology, Westfaelische Wilhelms-Univ., Muenster (Germany); Overbeck, J. [Dept. of Traumatic and Hand Surgery, Westfaelische Wilhelms-Univ., Muenster (Germany); Fiebich, M. [Dept. of Clinical Radiology, Westfaelische Wilhelms-Univ., Muenster (Germany); Peters, P.E. [Dept. of Clinical Radiology, Westfaelische Wilhelms-Univ., Muenster (Germany)

    1994-08-01

    The aim of the study was to evaluate the potential of magnification radiography in diagnosing fracture healing and assessing its complications. Seventy-three patients with fractures or who had undergone osteotomy were radiographed with both conventional (non-magnified) and magnification (5-fold) techniques. Since 10 patients were radiographed twice and 1 three times, 83 radiographs using each technique were obtained. All radiographs were analysed and the findings correlated with the patients` follow-up studies. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 {mu}m. As an imaging system, digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Magnification radiography proved superior to conventional radiography in 47% of cases: endosteal and periosteal callus formations were seen earlier and better in 26 cases, and osseous union could be evaluated with greater certainty in 33 cases. In 49% of cases magnification radiography was equal and in 4% inferior to conventional radiography. Additionally an ``inter-observer analysis`` was carried out. Anatomical and pathological structures were classified into one of four grades. Results were significantly (P < 0.01) better using magnification radiography. We conclude that the magnification technique is a good method for monitoring fracture healing in its early stages. (orig.)

  8. Digital chest radiography: collimation and dose reduction

    DEFF Research Database (Denmark)

    Debess, Jeanne; Johnsen, Karen Kirstine; Vejle-Sørensen, Jens Kristian

    Purpose: Quality improvement of basic radiography focusing on collimation and dose reduction in digital chest radiography Methods and Materials:A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from...... of clinical supervisors. Optimal collimation is determined by European and Regional Danish guidelines. The areal between current and optimal collimation is calculated. The experimental research is performed in September - October 2014 Siemens Axiom Aristos digital radiography system DR using 150 kV, 1,25 -3...

  9. New computed radiography processing condition for whole-spine radiography.

    Science.gov (United States)

    Sasagawa, Takeshi; Kunogi, Junichi; Masuyama, Shigeru; Ogihara, Satoshi; Takeuchi, Yosuke; Takeshita, Yujiro; Kamiya, Naokazu; Murakami, Hideki; Tsuchiya, Hiroyuki

    2011-12-06

    Computed radiography (CR) has many advantages compared with conventional radiographs, especially in image processing. Although CR is being used in chest radiography and mammography, it has not been applied to spine imaging. The purposes of this study were to formulate a set of new CR processing parameters and to test whether the resultant whole-spine radiographs visualized the spine more clearly than conventional images. This study included 29 patients who underwent whole-spine radiographs. We used 3 image processing methods to improve the clarity of whole-spine radiographs: gradation processing, dynamic range control processing, and multi-objective frequency processing. Radiograph definition was evaluated using vertebrae sampled from each region of the whole spine, specifically C4, C7, T8, T12, and L3; evaluation of the lateral view also included the sacral spine and femoral head. Image definition was assessed using a 3-point grading system. The conventional and processed CR images (both frontal and lateral views) were evaluated by 5 spine surgeons. In all spinal regions on both frontal and lateral views, the processed images showed statistically significantly better clarity than the corresponding conventional images, especially at T12, L3, the sacral spine, and the femoral head on the lateral view. Our set of new CR processing parameters can improve the clarity of whole-spine radiographs compared with conventional images. The greatest advantage of image processing was that it enabled clear depiction of the thoracolumbar junction, lumbar vertebrae, sacrum, and femoral head in the lateral view.

  10. Multiple imaging radiography at LNLS

    Energy Technology Data Exchange (ETDEWEB)

    Hoennicke, M.G. [LORXI, Departamento de Fisica, Universidade Federal do Parana, Caixa Postal 19091, 81531-990 Curitiba (Brazil)], E-mail: marcelohonnicke@yahoo.com.br; Cusatis, C. [LORXI, Departamento de Fisica, Universidade Federal do Parana, Caixa Postal 19091, 81531-990 Curitiba(Brazil); Antunes, A. [Departamento de Fisica Aplicada, Instituto de Fisica, Universidade de Sao Paulo, Caixa Postal 66318, 05315-970 Sao Paulo (Brazil); Safatle, A.M.V.; Barros, P.S.M. [Laboratorio de Oftalmologia Experimental e Comparativa, Departamento de Cirurgia, Faculdade de Medicina Veterinaria, Universidade de Sao Paulo, 05508-900 Sao Paulo (Brazil); Morelhao, S.L. [Departamento de Fisica Aplicada, Instituto de Fisica, Universidade de Sao Paulo, Caixa Postal 66318, 05315-970 Sao Paulo (Brazil)

    2008-01-11

    An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.

  11. Computational radiology in skeletal radiography

    Energy Technology Data Exchange (ETDEWEB)

    Peloschek, Ph.; Nemec, S. [Computational Image Analysis and Radiology Lab (CIR), Department of Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Widhalm, P. [Computational Image Analysis and Radiology Lab (CIR), Department of Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Pattern Recognition and Image Processing Group, Department of Computer Aided Automation, Vienna University of Technology, Wiedner Hauptstrasse 8-10/020, A-1040 Vienna (Austria); Donner, R. [Computational Image Analysis and Radiology Lab (CIR), Department of Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Pattern Recognition and Image Processing Group, Department of Computer Aided Automation, Vienna University of Technology, Wiedner Hauptstrasse 8-10/020, A-1040 Vienna (Austria); Institute for Computer Graphics and Vision, Graz University of Technology, Inffeldgasse 16, A-8010 Graz (Austria); Birngruber, E. [Computational Image Analysis and Radiology Lab (CIR), Department of Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Thodberg, H.H. [Visiana Aps, Sollerodvej 57C, DK-2840 Holte (Denmark); Kainberger, F. [Computational Image Analysis and Radiology Lab (CIR), Department of Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Langs, G. [Computational Image Analysis and Radiology Lab (CIR), Department of Radiology, Medical University Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)], E-mail: georg.langs@meduniwien.ac.at

    2009-11-15

    Recent years have brought rapid developments in computational image analysis in musculo-skeletal radiology. Meanwhile the algorithms have reached a maturity that makes initial clinical use feasible. Applications range from joint space measurement to erosion quantification, and from fracture detection to the assessment of alignment angles. Current results of computational image analysis in radiography are very promising, but some fundamental issues remain to be clarified, among which the definition of the optimal trade off between automatization and operator-dependency, the integration of these tools into clinical work flow and last not least the proof of incremental clinical benefit of these methods.

  12. NEUTRON RADIOGRAPHY: A SECOND PROGRESS REPORT

    Energy Technology Data Exchange (ETDEWEB)

    Berger, H

    1962-08-31

    The progress made on investigations of neutron radiography since October 1960 is discussed. The problems of the production of the neutron image will be discussed. The emphasis will be on the characteristics of many of the photographic imaging methods which can be used for neutron radiography. (auth)

  13. Process waste assessment for the Radiography Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, N.M.

    1994-07-01

    This Process Waste Assessment was conducted to evaluate the Radiography Laboratory, located in Building 923. It documents the processes, identifies the hazardous chemical waste streams generated by these processes, recommends possible ways to minimize waste, and serves as a reference for future assessments of this facility. The Radiography Laboratory provides film radiography or radioscopy (electronic imaging) of weapon and nonweapon components. The Radiography Laboratory has six x-ray machines and one gamma ray source. It also has several other sealed beta- and gamma-ray isotope sources of low microcurie ({mu}Ci) activity. The photochemical processes generate most of the Radiography Laboratory`s routinely generated hazardous waste, and most of that is generated by the DuPont film processor. Because the DuPont film processor generates the most photochemical waste, it was selected for an estimated material balance.

  14. Kyphoplasty combined with intraoperative radiotherapy (Kypho-IORT). Alternative therapy for patients with oligometastatic spinal metastases; Kyphoplastie kombiniert mit intraoperativer Radiotherapie (Kypho-IORT). Therapiealternative fuer den oligometastasierten Patienten mit Wirbelsaeulenmetastasen

    Energy Technology Data Exchange (ETDEWEB)

    Bludau, F.; Obertacke, U. [Universitaetsklinikum Mannheim, Med. Fakultaet Mannheim der Universitaet Heidelberg, Orthopaedisch-Unfallchirurgisches Zentrum, Mannheim (Germany); Reis, T.; Schneider, F.; Clausen, S.; Wenz, F. [Universitaetsklinikum Mannheim, Med. Fakultaet Mannheim der Universitaet Heidelberg, Klinik fuer Strahlentherapie und Radioonkologie, Mannheim (Germany)

    2015-10-15

    deutlich verbesserten Ueberlebenszeit, sondern auch zu einer Zunahme an ossaeren Metastasen bei Tumorpatienten. Die haeufigste Lokalisation stellt dabei die Wirbelsaeule dar, die Folge koennen Instabilitaet, Schmerz und neurologische Defizite sein. Das interdisziplinaere Tumormanagement der Wirbelsaeule umfasste bisher insbesondere die Stabilisierung und anschliessende Bestrahlung der Metastasen. Eine Reduktion der Eingriffsschwere und Morbiditaet sind ebenso wie die Beachtung und Erhalt der Autarkie des Patienten wichtige Zielparameter bei diesen palliativen Patienten. Die Kyphoplastie kombiniert mit intraoperativer Radiotherapie (Kypho-IORT) stellt eine weitere, moderne Behandlungsoption fuer Patienten dar, bei welcher minimal-invasiv eine lokale Hochdosisbestrahlung im Wirbelkoerper mittels niedrigenergetischen Roentgenstrahlen (50 kV) transpedikulaer vorgenommen wird. Unmittelbar anschliessend erfolgt die Stabilisierung des Wirbelkoerpers ueber das gleiche Portal mittels Kyphoplastie, sodass eine einzeitige Prozedur mit guter Schmerzreduktion und guter lokaler Tumorkontrolle erzielt werden kann. Neben der Praesentation klinischer Daten werden die Indikationsstellungen zur Kypho-IORT in diesem Artikel kritisch dargestellt und mit anderen Therapieoptionen verglichen. Methodische Verbesserungen und Moeglichkeiten zur weiteren Individualisierung der Therapie werden aufgezeigt. Die Kypho-IORT ist eine neue Behandlungsoption fuer Patienten mit Wirbelsaeulenmetastasen. Nach ueber 100 erfolgreichen Anwendungen sind technische Machbarkeit, Patientensicherheit und gute lokale Tumorkontrolle dargelegt, sodass eine Anwendung im klinischen Alltag moeglich und sinnvoll erscheint. Eine Phase-II-Dosiseskalationsstudie ist abgeschlossen und zur Publikation eingereicht, eine Phase-III-Studie zum Vergleich mit konventioneller Bestrahlung ist begonnen worden. (orig.)

  15. Ätzen von Titannitrid mit Halogenverbindungen

    OpenAIRE

    Hellriegel, Ronald

    2009-01-01

    Mit zunehmender Miniaturisierung mikroelektronischer Bauelemente steigen die Anforderungen an reproduzierbare qualitätskonforme Schichten. Um die zur Herstellung notwendigen ALD/PVD/CVD-Schichtabscheideanlagen in einen zuverlässigen Zustand zu versetzen, ist eine regelmäßige Kammerreinigung notwendig. Während des Abscheideprozesses werden nicht nur das Substrat, sondern auch die umliegenden Kammerteile beschichtet. Diese Schichten wachsen mit jedem Beschichtungszyklus weiter an. Der Stres...

  16. Photovoltaik Hybrid-Solarzellen mit Nanopartikeln

    Science.gov (United States)

    Leute, Angelika

    2004-09-01

    Die organische Photovoltaik auf der Basis halbleitender Polymere bietet eine kostengünstige Alternative zu Solarzellen aus Silizium. Allerdings weisen die organischen Materialien relativ schlechte Ladungstransporteigenschaften auf. Hybrid-Solarzellen, in denen Polymere mit geeigneten anorganischen Halbleitern kombiniert sind, besitzen einerseits die praktischen Vorteile der Organik und andererseits die hohe Elektronenbeweglichkeit der anorganischen Materialien. Wissenschaftler der Technischen Universität Eindhoven haben kürzlich Hybrid-Solarzellen vorgestellt, die aus einem halbleitenden Polymer mit Zinkoxid-Nanopartikeln bestehen.

  17. Using mechanical produced TI-moduls with a favourable facade construction for prefabricated building with light concrete slabs. Final report; Einsatz maschinell gefertigter TWD-Module in einer optimierten Fassadenkonstruktion an Montagebauten mit Leichtbetonelementen. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Russ, C. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany); Klinkert, V. [Hochschule fuer Technik, Wirtschaft und Kultur Leipzig (F.H.) (Germany)

    2000-07-01

    Senkung des Heizwaermeverbrauches im Gebaeudebestand liegt heute ein grosses Potential zur Energieeinsparung und Vermeidung von Schadstoffemissionen. Mittels aktiver und passive solarer Techniken kann bei der Gebaeudesanierung das Einsparpotential gegenueber rein konventioneller Technik wesentlich verbessert werden. Die Nutzung transparenter Waermedaemmung bei der Sanierung ist sinnvoll in ein komplettes energetisches Sanierungskonzept einzubinden. Fuer Montagebauten mit Leichtbetonelementen ergeben sich hierbei besondere Anforderungen an die konstruktive Ausfuehrung der TWD-Fassade. In Verbindung mit einem, den solaren Gewinnen angepassten Regelsystem der Heizung erhaelt man gute Voraussetzungen fuer die optimale solare Ertraege. Im Gesamtkonzept einer effizienten Waermedaemmung der Gebaeudehuelle, einer Waermeschutzverglasung und einer Einzelraumtemperaturreglung konnte der Heinzwaermeverbrauch im Gebaeude um 69% reduziert werden. Gegenueber dem Einsatz rein konventioneller Technik erbrachte der Einsatz transparenter Waermedaemmung eine weiter Senkung des Heizwaermebedarfs um 18%. Es wurde ein spezifischer Waermeertrag von 53 kW/m{sup 2} bei einen aequivalenten Energiepreis fuer die Gesamtsanierung von 0,45 DM (mit Foerderung 0,24 DM) erreicht. Mit rund 1,00 DM ungefoerderten aequivalenten Energiepreis fuer die passive Solarenergienutzung ueber die TWD-Fassade sind die spezifischen Energiekosten noch zu hoch. Weitere Kosteneinsparungen sind hier vor allem in den Modulkosten (Material, maschinelle Herstellung, grosse Losgroessen) erforderlich. Transparent gedaemmte Waende haben ueber das gesamte Jahr Waermegewinne. Unter Beachtung der vermiedenen Waermeverluste konnte fuer die transparent gedaemmten Waende ein energetischer Gewinn von 76 kWh/m{sup 2} ermittelt werden. Der in der Heizphase erreichte solare Wirkungsgrad liegt bei 18%. Mit dem Einsatz transparenter Waermedaemmung wurde dokumentiert, dass solare Gewinne wesentlich dazu beitragen, die Grundtemperatur im

  18. Using mechanical produced TI-moduls with a favourable facade construction for prefabricated building with light concrete slabs. Final report; Einsatz maschinell gefertigter TWD-Module in einer optimierten Fassadenkonstruktion an Montagebauten mit Leichtbetonelementen. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Russ, C. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany); Klinkert, V. [Hochschule fuer Technik, Wirtschaft und Kultur Leipzig (F.H.) (Germany)

    2000-07-01

    Senkung des Heizwaermeverbrauches im Gebaeudebestand liegt heute ein grosses Potential zur Energieeinsparung und Vermeidung von Schadstoffemissionen. Mittels aktiver und passive solarer Techniken kann bei der Gebaeudesanierung das Einsparpotential gegenueber rein konventioneller Technik wesentlich verbessert werden. Die Nutzung transparenter Waermedaemmung bei der Sanierung ist sinnvoll in ein komplettes energetisches Sanierungskonzept einzubinden. Fuer Montagebauten mit Leichtbetonelementen ergeben sich hierbei besondere Anforderungen an die konstruktive Ausfuehrung der TWD-Fassade. In Verbindung mit einem, den solaren Gewinnen angepassten Regelsystem der Heizung erhaelt man gute Voraussetzungen fuer die optimale solare Ertraege. Im Gesamtkonzept einer effizienten Waermedaemmung der Gebaeudehuelle, einer Waermeschutzverglasung und einer Einzelraumtemperaturreglung konnte der Heinzwaermeverbrauch im Gebaeude um 69% reduziert werden. Gegenueber dem Einsatz rein konventioneller Technik erbrachte der Einsatz transparenter Waermedaemmung eine weiter Senkung des Heizwaermebedarfs um 18%. Es wurde ein spezifischer Waermeertrag von 53 kW/m{sup 2} bei einen aequivalenten Energiepreis fuer die Gesamtsanierung von 0,45 DM (mit Foerderung 0,24 DM) erreicht. Mit rund 1,00 DM ungefoerderten aequivalenten Energiepreis fuer die passive Solarenergienutzung ueber die TWD-Fassade sind die spezifischen Energiekosten noch zu hoch. Weitere Kosteneinsparungen sind hier vor allem in den Modulkosten (Material, maschinelle Herstellung, grosse Losgroessen) erforderlich. Transparent gedaemmte Waende haben ueber das gesamte Jahr Waermegewinne. Unter Beachtung der vermiedenen Waermeverluste konnte fuer die transparent gedaemmten Waende ein energetischer Gewinn von 76 kWh/m{sup 2} ermittelt werden. Der in der Heizphase erreichte solare Wirkungsgrad liegt bei 18%. Mit dem Einsatz transparenter Waermedaemmung wurde dokumentiert, dass solare Gewinne wesentlich dazu beitragen, die Grundtemperatur im

  19. Grading sacroiliitis with emphasis on MRI imaging; Grading der Sakroiliitis mit Betonung der MRT-Bildgebung

    Energy Technology Data Exchange (ETDEWEB)

    Jurik, A.G.; Egund, N. [The Department of Radiology R, Aarhus Kommunehospital (Denmark)

    2004-03-01

    -Veraenderungen bei SpA mit einer sensitiveren Methode als der konventionellen Radiographie bei der Evaluation der Therapie von grosser Wichtigkeit sein, wie z. B. die Wirksamkeit neuer biologischer Therapeutika, die gegen den Tumornekrosefaktor-{alpha} (TNF-{alpha}) gerichtet sind. Es wird ein Ueberblick ueber die verfuegbaren Gradingmethoden gegeben und MRT- und CT-Verfahren werden praesentiert. (orig.)

  20. Standard guide for computed radiography

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide provides general tutorial information regarding the fundamental and physical principles of computed radiography (CR), definitions and terminology required to understand the basic CR process. An introduction to some of the limitations that are typically encountered during the establishment of techniques and basic image processing methods are also provided. This guide does not provide specific techniques or acceptance criteria for specific end-user inspection applications. Information presented within this guide may be useful in conjunction with those standards of 1.2. 1.2 CR techniques for general inspection applications may be found in Practice E2033. Technical qualification attributes for CR systems may be found in Practice E2445. Criteria for classification of CR system technical performance levels may be found in Practice E2446. Reference Images Standards E2422, E2660, and E2669 contain digital reference acceptance illustrations. 1.3 The values stated in SI units are to be regarded as the st...

  1. Proton Radiography at Los Alamos

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, Alexander [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-02-28

    The proton radiography (pRad) facility at Los Alamos National Lab uses high energy protons to acquire multiple frame flash radiographic sequences at megahertz speeds: that is, it can make movies of the inside of explosions as they happen. The facility is primarily used to study the damage to and failure of metals subjected to the shock forces of high explosives as well as to study the detonation of the explosives themselves. Applications include improving our understanding of the underlying physical processes that drive the performance of the nuclear weapons in the United States stockpile and developing novel armor technologies in collaboration with the Army Research Lab. The principle and techniques of pRad will be described, and examples of some recent results will be shown.

  2. Untersuchungen an Eisen- und Lanthanoidhaltigen Koordinationsclustern mit Triazolat- sowie Semiquinonato-Liganden

    OpenAIRE

    Kriese, Thomas

    2016-01-01

    Magnetische Untersuchungen an Lanthanoiddimeren mit Semiquinonato-Liganden. Gemischtvalente Eisen-Koordinationsclustern. Lanthanoid-Koordinationscluster mit zwölf Lanthanoiden aber mit verschiedenen Clusterladungen.

  3. Minimally invasive thyroidectomy (MIT): indications and results.

    Science.gov (United States)

    Docimo, Giovanni; Salvatore Tolone, Salvatore; Gili, Simona; d'Alessandro, A; Casalino, G; Brusciano, L; Ruggiero, Roberto; Docimo, Ludovico

    2013-01-01

    To establish if the indication for different approaches for thyroidectomy and the incision length provided by means of pre-operative assessment of gland volume and size of nodules resulted in safe and effective outcomes and in any notable aesthetic or quality-of-life impact on patients. Ninehundred eightytwo consecutive patients, undergoing total thyroidectomy, were enrolled. The thyroid volume and maximal nodule diameter were measured by means of ultrasounds. Based on ultrasounds findings, patients were divided into three groups: minimally invasive video assisted thyroidectomy (MIVAT), minimally invasive thyroidectomy (MIT) and conventional thyroidectomy (CT) groups. The data concerning the following parameters were collected: operative time, postoperative complications, postoperative pain and cosmetic results. The MIVAT group included 179 patients, MIT group included 592 patients and CT group included 211 patients. Incidence of complications did not differ significantly in each group. In MIVAT and MIT group, the perception of postoperative pain was less intense than CT group. The patients in the MIVAT (7±1.5) and MIT (8±2) groups were more satisfied with the cosmetic results than those in CT group (5±1.3) (p= MIT is a technique totally reproducible, and easily convertible to perform surgical procedures in respect of the patient, without additional complications, increased costs, and with better aesthetic results.

  4. Estimation of patient exposure in dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Yasaki, Shiro; Yukishita, Kentaro; Daibo, Motoji; Suzuki, Yousuke [Ohu Univ., Koriyama, Fukushima (Japan). School of Dentistry

    1998-12-01

    Purpose of this study is to examine comparison of absorbed dose in each mode of newest Multimode Panoramic Radiography and Dental Radiography. The absorbed dose of Dental Radiography uses modified IWAI`s data. The effective doses were calculated using modified tissue weighting factors recommended by International Commission on Radiological Protection (ICRP) in 1990. The result of estimate in effective dose, panoramic auto function mode (4.92 {mu}Sv) was lower than dental full mouth (43.12 {mu}Sv). And clinical effective dose was higher than the other`s modes, in linear tomogram modes. The absorbed dose of patient in Dental Radiography is decreasing in recent years. But in daily clinical work we should pay atteation to justification and optimization. (author)

  5. Imaging beamline for high energy proton radiography

    Institute of Scientific and Technical Information of China (English)

    WEI Tao; YANG Guo-Jun; LONG Ji-Dong; WANG Shao-Heng; HE Xiao-Zhong

    2012-01-01

    Proton radiography is a new tool for advanced hydrotesting.This article will discuss the basic concept of proton radiography first,especially the magnetic lens system.Then a scenario of 50 GeV imaging beamline will be described in every particular,including the matching section,Zumbro lens system and imaging system.The simulation result shows that the scenario of imaging beamline performs well,and the influence of secondary particles can be neglected.

  6. Technique and radiation dose of conventional X-rays and computed tomography of the sacroiliac joint; Technik und Strahlendosis konventioneller Roentgenaufnahmen und Computertomographie des Sakroiliakalgelenks

    Energy Technology Data Exchange (ETDEWEB)

    Jurik, A.G. [Department of Radiology R, Aarhus Kommunehospital (Denmark)

    2004-03-01

    Anterior-posterior (a.p.) or posterior-anterior X-rays of the sacroiliac joint, sometimes supplemented by a transverse view, have been the method of choice for diagnosis of patients suspected of having sacroiliitis. The sensitivity and specificity of conventional X-rays are relatively low, which can delay the diagnosis of sacroiliitis. Computed tomography (CT) is superior to conventional X-rays for diagnosis of sacroiliitis, but does emit a relatively higher dose of radiation. For this reason, particularly for females, CT should be optimized by employing semi-coronal planes, which require a lower radiation dose than axial planes. CT in a semi-coronal plane causes minimal radiation to the ovaries, and the effective radiation dose for women might even be lower than with conventional AP X-rays. Therefore, for suspected sacroiliitis in young women, CT in the semi-coronal plane is the preferred imaging method with respect to diagnostics and radiation protection when magnetic resonance imaging (MRI) is not available. Male gonads can be protected from radiation doses in conventional X-rays, and CT as the primary imaging method can only be justified in these cases because of its better diagnostic capabilities. Due to the lack of inherent risk factors, MRI is superior to CT for diagnostics since it provides images of inflammatory signs in addition to joint destruction. Thus, when available, MRI should be given preference for diagnosis of sacroiliitis. (orig.) [German] Roentgenaufnahmen des Sakroiliakalgelenks im anterior-posterioren bzw. posterior-anterioren Strahlengang, gelegentlich ergaenzt durch die Schraegaufnahme, sind seit vielen Jahren die Methode der Wahl fuer die Diagnostik bei Patienten mit Verdacht auf Sakroiliitis. Die Sensitivitaet und Spezifitaet des konventionellen Roentgens sind relativ niedrig, was die Diagnose der Sakroiliitis verzoegern koennte. Die Computertomographie (CT) ist dem konventionellen Roentgen fuer die Diagnostik der Sakroiliitis ueberlegen

  7. Simulation of proton radiography terminal at IMP

    CERN Document Server

    Yan, Yan; Huang, Zhi-Wu; Wang, Jie; Yao, Ze-En; Wang, Jun-Run; Wei, Zheng; Yang, Jian-Cheng; Yuan, You-Jin

    2015-01-01

    Proton radiography is used for advanced hydrotesting as a new type radiography technology due to its powerful penetration capability and high detection efficiency. A new proton radiography terminal will be developed to radiograph static samples at Institute of Modern Physics of Chinese Academy of Science (IMP-CAS). The proton beam with the maximum energy of 2.6 GeV will be produced by Heavy Ion Research Facility in Lanzhou-Cooling Storage Ring (HIRFL-CSR). The proton radiography terminal consists of the matching magnetic lens and the Zumbro lens system. In this paper, the design scheme and all optic parameters of this beam terminal for 2.6GeV proton energy are presented by simulating the beam optics using WINAGILE code. My-BOC code is used to test the particle tracking of proton radiography beam line. Geant4 code and G4beamline code are used for simulating the proton radiography system. The results show that the transmission efficiency of proton without target is 100%, and the effect of secondary particles ca...

  8. Kompressionstherapie bei Patienten mit Ulcus cruris venosum.

    Science.gov (United States)

    Dissemond, Joachim; Assenheimer, Bernd; Bültemann, Anke; Gerber, Veronika; Gretener, Silvia; Kohler-von Siebenthal, Elisabeth; Koller, Sonja; Kröger, Knut; Kurz, Peter; Läuchli, Severin; Münter, Christian; Panfil, Eva-Maria; Probst, Sebastian; Protz, Kerstin; Riepe, Gunnar; Strohal, Robert; Traber, Jürg; Partsch, Hugo

    2016-11-01

    Wund-D.A.CH. ist der Dachverband deutschsprachiger Fachgesellschaften, die sich mit den Thematiken der Wundbehandlung beschäftigen. Experten verschiedener Fachgesellschaften aus Deutschland, Österreich und der Schweiz haben nun einen aktuellen Konsens der Kompressionstherapie für Patienten mit Ulcus cruris venosum erstellt. In Europa ist das Ulcus cruris venosum eine der häufigsten Ursachen für chronische Wunden. Neben der konservativen und interventionellen Wund- und Venentherapie, ist die Kompressionstherapie die Basis der Behandlungsstrategien. Die Kompressionstherapie kann heute mit sehr unterschiedlichen Materialien und Systemen durchgeführt werden. Während in der Entstauungsphase insbesondere Verbände mit Kurzzugbinden oder Mehrkomponentensysteme zur Anwendung kommen, sind es anschließend überwiegend Ulkus-Strumpfsysteme. Eine weitere, bislang wenig verbreitete Alternative sind adaptive Kompressionsbandagen. Insbesondere für die Rezidivprophylaxe werden medizinische Kompressionsstrümpfe empfohlen. Durch die Vielzahl der heute zur Verfügung stehenden Behandlungsoptionen, kann für nahezu alle Patienten ein Konzept entwickelt werden, dass sich an den individuellen Bedürfnissen und Fähigkeiten orientiert und daher auch akzeptiert und durchgeführt wird. Die Kompressionstherapie ist für die Behandlung von Patienten mit Ulcus cruris venosum essentiell. In den letzten Jahren sind viele verschiedene Therapieoptionen verfügbar, die in den deutschsprachigen Ländern unterschiedlich angewendet oder durchgeführt werden. Daher soll dieser Expertenkonsens dazu beitragen, konkrete Empfehlungen für die praktische Durchführung der Kompressionstherapie von Patienten mit Ulcus cruris venosum darzustellen. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  9. Results of high intensity afterloading irradiation with 192 iridium in the therapy of genital tumors in women under different dose rates, fractionations and total doses in comparison with conventional radium contact irradiation. Ergebnisse der High-Intensity-Afterloadingbestrahlung mit 192 Iridium in der Therapie von Genitaltumoren der Frau unter verschiedenen Dosisleistungen, Fraktionierungen und Gesamtdosen im Vergleich mit konventioneller Radiumkontaktbestrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Giers, G.

    1986-05-07

    In comparison to conventional radium therapy are to be evaluated the results of the high intensity afterloading technique with the help of the parameters survial rate and complication rate. Thereby were included in the examination 4 documentations of results (collum, cervix stump, corpus and vaginal carcinoma) with altogether 742 patients with 2806 single irradiations and an evaluation of the therapy after several modifications of the therapy schemes. The 5-year survival rate was in the case of collum carcinoma: 68.4%, cervix stump: 50%, corpus carcinoma: 76%, and vaginal carcinoma: 66.6%. The corresponding 3-year survival rates were: 74.2%, 80%, 84% and 70% with primary irradiation. Only with cervix stump carcinoma were the values for post-operative irradiation. The description of the irradiation results showed, that with the changing of the fractionation mode and the dose level in collum and corpus carcinoma the irreversible complications as an expression of the success of a new therapy were reduced. The for now best suited therapy schema (fractionation and dosing) are described. (TRV).

  10. Proton radiography for clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Talamonti, C., E-mail: cinzia.talamonti@unifi.i [Dipartimento di Fisiopatologia Clinica, Universita degli Studi di Firenze, v.le Morgagni 85, I-50134 Firenze (Italy); INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Azienda Ospedaliero-Universitaria Careggi, v.le Morgagni 85, I-50134 Firenze (Italy); Reggioli, V. [Dipartimento di Fisiopatologia Clinica, Universita degli Studi di Firenze, v.le Morgagni 85, I-50134 Firenze (Italy); Bruzzi, M. [INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Dipartimento di Energetica, Universita degli Studi di Firenze, via S. Marta 3, I-50139 Firenze (Italy); Bucciolini, M. [Dipartimento di Fisiopatologia Clinica, Universita degli Studi di Firenze, v.le Morgagni 85, I-50134 Firenze (Italy); INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Azienda Ospedaliero-Universitaria Careggi, v.le Morgagni 85, I-50134 Firenze (Italy); Civinini, C. [INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Marrazzo, L. [Azienda Ospedaliero-Universitaria Careggi, v.le Morgagni 85, I-50134 Firenze (Italy); Menichelli, D. [INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Finland) (Italy); Dipartimento di Energetica, Universita degli Studi di Firenze, via S. Marta 3, I-50139 Firenze (Italy); Pallotta, S. [Dipartimento di Fisiopatologia Clinica, Universita degli Studi di Firenze, v.le Morgagni 85, I-50134 Firenze (Italy); INFN, sezione di Firenze, via G. Sansone 1, I-50019 Sesto Fiorentino (Italy); Azienda Ospedaliero-Universitaria Careggi, v.le Morgagni 85, I-50134 Firenze (Italy); Randazzo, N. [INFN, sezione di Catania, via S. Sofia 64, I-95123 Catania (Italy); Sipala, V. [INFN, sezione di Catania, via S. Sofia 64, I-95123 Catania (Italy); Dipartimento di Fisica, Universita degli Studi di Catania, via S. Sofia 64, I-95123 Catania (Italy)

    2010-01-11

    Proton imaging is not yet applied as a clinical routine, although its advantages have been demonstrated. In the context of quality assurance in proton therapy, proton images can be used to verify the correct positioning of the patient and to control the range of protons. Proton computed tomography (pCT) is a 3D imaging method appropriate for planning and verification of proton radiation treatments, because it allows evaluating the distributions of proton stopping power within the tissues and can be directly utilized when the patient is in the actual treatment position. The aim of the PRoton IMAging experiment, supported by INFN, and the PRIN 2006 project, supported by MIUR, is to realize a proton computed radiography (pCR) prototype for reconstruction of proton images from a single projection in order to validate the technique with pre-clinical studies and, eventually, to conceive the configuration of a complete pCT system. A preliminary experiment performed at the 250 MeV proton synchrotron of Loma Linda University Medical Center (LLUMC) allowed acquisition of experimental data before the completion of PRIMA project's prototype. In this paper, the results of the LLUMC experiment are reported and the reconstruction of proton images of two phantoms is discussed.

  11. Thorium-uranium fission radiography

    Science.gov (United States)

    Haines, E. L.; Weiss, J. R.; Burnett, D. S.; Woolum, D. S.

    1976-01-01

    Results are described for studies designed to develop routine methods for in-situ measurement of the abundance of Th and U on a microscale in heterogeneous samples, especially rocks, using the secondary high-energy neutron flux developed when the 650 MeV proton beam of an accelerator is stopped in a 42 x 42 cm diam Cu cylinder. Irradiations were performed at three different locations in a rabbit tube in the beam stop area, and thick metal foils of Bi, Th, and natural U as well as polished silicate glasses of known U and Th contents were used as targets and were placed in contact with mica which served as a fission track detector. In many cases both bare and Cd-covered detectors were exposed. The exposed mica samples were etched in 48% HF and the fission tracks counted by conventional transmitted light microscopy. Relative fission cross sections are examined, along with absolute Th track production rates, interaction tracks, and a comparison of measured and calculated fission rates. The practicality of fast neutron radiography revealed by experiments to data is discussed primarily for Th/U measurements, and mixtures of other fissionable nuclei are briefly considered.

  12. Mobile real time radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Vigil, J.; Taggart, D.; Betts, S. [Los Alamos National Lab., NM (United States)] [and others

    1997-11-01

    A 450-keV Mobile Real Time Radiography (RTR) System was delivered to Los Alamos National Laboratory (LANL) in January 1996. It was purchased to inspect containers of radioactive waste produced at (LANL). Since its delivery it has been used to radiograph more than 600 drums of radioactive waste at various LANL sites. It has the capability of inspecting waste containers of various sizes from <1-gal. buckets up to standard waste boxes (SWB, dimensions 54.5 in. x 71 in. x 37 in.). It has three independent x-ray acquisition formats. The primary system used is a 12- in. image intensifier, the second is a 36-in. linear diode array (LDA) and the last is an open system. It is fully self contained with on board generator, HVAC, and a fire suppression system. It is on a 53-ft long x 8-ft. wide x 14-ft. high trailer that can be moved over any highway requiring only an easily obtainable overweight permit because it weights {approximately}38 tons. It was built to conform to industry standards for a cabinet system which does not require an exclusion zone. The fact that this unit is mobile has allowed us to operate where the waste is stored, rather than having to move the waste to a fixed facility.

  13. Grosse Axiallager mit Hybridschmierung - Theoretische und experimentelle Betrachtungen

    DEFF Research Database (Denmark)

    Santos, Ilmar; Fuerst, Axel

    2003-01-01

    Der vorliegende Artikel praesentiert die Simulation eines grossen axialen Kippsegmentlagers unter Beruecksichtigung der hybriden Schmierung, d.h. gleichzeitige hydrodynamische und hydrostatische Schmierung. Ein Vergleich mit Messungen zeigt, dass fuer das betrachtete Lager mit 2,2 m Durchmesser d...

  14. Deeskalation der Immuntherapie bei Patienten mit Multipler Sklerose

    OpenAIRE

    2016-01-01

    Die vorliegende Arbeit ist die erste, die sich mit der Frage beschäftigt, mit welcher zur Deeskalation eingesetzten Therapie nach Beendigung einer Eskalationstherapie mit Mitoxantron am besten Krankheitsstabilität erreicht werden kann bzw. ob Patienten-/Krankheitscharakteristika existieren, die eine bestimmte Nachfolge-Therapie favorisieren. Trotz neuer Behandlungsmöglichkeiten der hochaktiven MS mit Fingolimod, Natalizumab und Alemtuzumab hat Mitoxantron im klinischen Alltag nach wie vor ...

  15. Magnetic resonance imaging and magnetic resonance arthography of the acetabular labrum: Comparison with surgical findings; Magnetresonanztomographie und Magnetresonanzarthrographie des Labrum acetabulare: Vergleich mit operativen Ergebnissen

    Energy Technology Data Exchange (ETDEWEB)

    Czerny, C. [Universitaetsklinik fuer Radiodiagnostik, Vienna (Austria). Abt. fuer Osteologie; Kramer, J. [Universitaetsklinik fuer Radiodiagnostik, Vienna (Austria). Abt. fuer Osteologie; Institut fuer bildgebende Diagnostik am Schillerpark, Linz (Austria); Neuhold, A. [Krankenhaus Rudolfinerhaus, Vienna (Austria). Inst. fuer bildgebende Diagnostik; Urban, M. [Krankenhaus Sozialmedizinisches Zentrum Ost, Vienna (Austria). Abt. fuer Radiodiagnostik; Tschauner, C. [Orthopaedisches Landeskrankenhaus Stolzalpe (Austria); Hofmann, S. [Krankenhaus Sozialmedizinisches Zentrum Ost, Vienna (Austria). Abt. fuer Radiodiagnostik; Orthopaedisches Landeskrankenhaus Stolzalpe (Austria)

    2001-08-01

    : Bei 40 Patienten (40 Hueftgelenke) mit klinischem Verdacht auf eine Labrumlaesion wurde das Hueftgelenk in koronaler und axialer Ebene mittels konventioneller MRT unter Verwendung von T{sub 1}-gewichteten und protonendichte-gewichteten Spinechosequenzen untersucht. Zusaetzlich wurde bei allen Patienten eine MR-Arthrographie des Hueftgelenkes mit schraeg-koronalen und schraeg-sagittalen 3D T{sub 1}-gewichteten Gradientenechosequenzen nach intraartikulaerer Injektion einer 2 mmol/Loesung von Gadolinium-DTPA durchgefuehrt. Die Labra wurden prospektiv hinsichtlich Morphologie, Signalintensitaet und Ein- oder Abrissen evaluiert und die MRT- und MR-Arthrographie-Befunde mit den operativ gefundenen Ergebnissen verglichen. Ergebnisse: Die Operationen ergaben 34 Labrumlaesionen und 6 unauffaellige Labra. Die MRT war bei 24 Labrumlaesionen und zwei unauffaelligen Labra diagnostisch richtig. Die MR-Arthrographie fuehrte bei 30 Labrumlaesionen und 5 unauffaelligen Labra zum richtigen Ergebnis. Die Sensitivitaet der MRT lag bei 80%, die Genauigkeit bei 65%, die Sensitivitaet der MR-Arthrographie bei 95% und die Genauigkeit bei 88%. Schlussfolgerungen: Verglichen mit der konventionallen MRT laesst sich die Aussagekraft hinsichtlich Laesionen des Labrum acetabulare mit der MR-Arthrographie signifikant verbessern. Die konventionelle MRT ist zur Abklaerung von Labrumlaesionen somit nur bedingt geeignet. Bei der Frage nach Labrumlaesionen ist der MR-Arthrographie der Vorzug zu geben. (orig.)

  16. MIT professor wins major international math prize

    CERN Multimedia

    Allen, S

    2004-01-01

    Mathematicians Isadore Singer of MIT and Sir Michael Francis Atiyah of the University of Edinburgh will share an $875,000 award as winners of the second Abel Prize, which some hope will come to be seen as a Nobel Prize for math.

  17. Mit Kindergartenkindern Medientechnologien ergründen

    DEFF Research Database (Denmark)

    Chimirri, Niklas Alexander

    2012-01-01

    Erklärungen für die Kind-Technik-Interaktion. Der Beitrag bezieht in einem Kindergarten erhobenes Datenmaterial ein, um das Konzept der alltäglichen Lebensführung für eine subjektwissenschaftliche Technikforschung mit Kindern fruchtbar zu machen. Die hier vorgeschlagene Erweiterung betont die Relevanz einer...

  18. Wrestling with Pedagogical Change: The TEAL Initiative at MIT

    Science.gov (United States)

    Breslow, Lori

    2010-01-01

    In the late 1990s, the physics department at the Massachusetts Institute of Technology (MIT) had a problem. The department was responsible for teaching the two required physics courses that are part of the General Institute Requirements (GIRs), MIT's core curriculum--Physics I (mechanics, or in MIT parlance, 8.01) and Physics II (electricity and…

  19. Wrestling with Pedagogical Change: The TEAL Initiative at MIT

    Science.gov (United States)

    Breslow, Lori

    2010-01-01

    In the late 1990s, the physics department at the Massachusetts Institute of Technology (MIT) had a problem. The department was responsible for teaching the two required physics courses that are part of the General Institute Requirements (GIRs), MIT's core curriculum--Physics I (mechanics, or in MIT parlance, 8.01) and Physics II (electricity and…

  20. Editorial 3/2015: Handeln mit Symbolen

    Directory of Open Access Journals (Sweden)

    Alessandro Barberi

    2015-09-01

    Full Text Available Die paradigmatische Unterscheidung zwischen Sozial- und Kulturwissenschaften, die spätestens seit den 1980er Jahren eingehend diskutiert wurde, lässt sich anhand des Bereichs des Symbolischen auf den Punkt bringen: Ist das Symbolische nur ein Effekt von sozialen, ökonomischen oder medialen Strukturen einer gegebenen Gesellschaft oder reproduzieren sich Strukturen nur durch die symbolischen Handlungen der AkteurInnen innerhalb einer gegebenen Kultur? So hatte etwa der klassische "harte" Strukturalismus bei Claude Lévi-Strauss, Jacques Lacan und dem frühen Michel Foucault symbolische Ordnungen (und d. i. hier die Sprache als eine unbewusst determinierende Voraussetzung von menschlicher Interaktion begriffen, woraufhin mit dem Post- bzw. Neostrukturalismus die Rückkehr der individuellen Äußerung, der parole, des speech acts (und d. i. hier das Sprechen, also der symbolischen Handlung in den Mittelpunkt rückte. Medienpädagogisch ist diese Unterscheidung gerade dann von Interesse, wenn es darum geht, wie Lehrende und Lernende sich zueinander verhalten, interagieren und dabei eben mit Symbolen handeln. Insofern ist es bemerkenswert, dass – fast parallel zu Foucaults Unterscheidung von diskursiven und nicht-diskursiven Praktiken – auch Dieter Baacke 1973 von diskursiven und nicht-diskursiven Symbolen gesprochen hat. Denn – wie auch im Rahmen des "Symbolischen Interaktionismus" von George Herbert Mead argumentiert wurde – können Symbole nur im Rahmen einer gegebenen Diskursökonomie von AkteurInnen diskursiv ausgetauscht werden und konstituieren dabei Erfahrungen bzw. Wahrnehmungen und somit auch die soziale bzw. kulturelle Wirklichkeit. Insofern ist die Frage nach dem Symbolischen immer auch eine Frage nach den Möglichkeiten der Handlungstheorie (im Sinne Jürgen Habermas’ bzw. der Praxeologie (im Sinne Pierre Bourdieus. Die Redaktion der MEDIENIMPULSE geht in diesem Zusammenhang theoretisch und praktisch von Entscheidungsimpulse

  1. Muon radiography for exploration of Mars geology

    Directory of Open Access Journals (Sweden)

    S. Kedar

    2013-06-01

    Full Text Available Muon radiography is a technique that uses naturally occurring showers of muons (penetrating particles generated by cosmic rays to image the interior of large-scale geological structures in much the same way as standard X-ray radiography is used to image the interior of smaller objects. Recent developments and application of the technique to terrestrial volcanoes have demonstrated that a low-power, passive muon detector can peer deep into geological structures up to several kilometers in size, and provide crisp density profile images of their interior at ten meter scale resolution. Preliminary estimates of muon production on Mars indicate that the near horizontal Martian muon flux, which could be used for muon radiography, is as strong or stronger than that on Earth, making the technique suitable for exploration of numerous high priority geological targets on Mars. The high spatial resolution of muon radiography also makes the technique particularly suited for the discovery and delineation of Martian caverns, the most likely planetary environment for biological activity. As a passive imaging technique, muon radiography uses the perpetually present background cosmic ray radiation as the energy source for probing the interior of structures from the surface of the planet. The passive nature of the measurements provides an opportunity for a low power and low data rate instrument for planetary exploration that could operate as a scientifically valuable primary or secondary instrument in a variety of settings, with minimal impact on the mission's other instruments and operation.

  2. Muon radiography for exploration of Mars geology

    Directory of Open Access Journals (Sweden)

    S. Kedar

    2012-10-01

    Full Text Available Muon radiography is a technique that uses naturally occurring showers of muons (penetrating particles generated by cosmic rays to image the interior of large scale geological structures in much the same way as standard X-ray radiography is used to image the interior of smaller objects. Recent developments and application of the technique to terrestrial volcanoes have demonstrated that a low-power, passive muon detector can peer deep into geological structures up to several kilometers in size, and provide crisp density profile images of their interior at ten meter scale resolution. Preliminary estimates of muon production on Mars indicate that the near horizontal Martian muon flux, which could be used for muon radiography, is as strong or stronger than that on Earth, making the technique suitable for exploration of numerous high priority geological targets on Mars. The high spatial resolution of muon radiography also makes the technique particularly suited for the discovery and delineation of Martian caverns, the most likely planetary environment for biological activity. As a passive imaging technique, muon radiography uses the perpetually present background cosmic ray radiation as the energy source for probing the interior of structures from the surface of the planet. The passive nature of the measurements provides an opportunity for a low power and low data rate instrument for planetary exploration that could operate as a scientifically valuable primary or secondary instrument in a variety of settings, with minimal impact on the mission's other instruments and operation.

  3. Behandlung von Herzrhythmusstörungen mit Magnesium bei Patienten mit Herzinsuffizienz

    Directory of Open Access Journals (Sweden)

    Wink K

    2002-01-01

    Full Text Available Die medikamentöse Behandlung von Herzrhythmusstörungen ist unbefriedigend, da bei guter Wirksamkeit durch die Proarrhythmie eine Verbesserung der Prognose gefährdet und nicht gesichert ist. Man kann davon ausgehen, daß Magnesiumsalze keine arrhythmogene Effekte aufweisen. Bei Patienten mit einer Herzinsuffizienz besteht häufig ein Mg-Mangel, der durch gastrointestinale Störungen, neurohormonale Regulationen, aber auch durch die Therapie (Diuretika,Digitalisbedingt ist. An Patienten mit einer Herzinsuffizienz müßte sich demnach zeigen lassen, ob die Mg-Substitution einen antiarrhythmischen Effekt aufweist. In fünf placebokontrollierten Studien konnte gezeigt werden, daß sich teil weise signifikant und mit ausreichen der Aussagekraft (PowerArrhythmien bei Patienten mit Herzinsuffizienz durch orale und parenterale Gabe von Mg-Salzen reduzieren lassen. Trotz Einschränkungen wie z.B. inadäquates Design, fehlende Vermeidung von Bias, ungenügende Vergleichbarkeit der Behandlungsgruppen, inadäquate Auswertung und ungenügende Berücksichtigung der Spontanvariation läßt sich aufgrund der Ergebnisse der Studien die Hypothese aufstellen, daß Magnesiumsalze bei Patienten mit Herzinsuffizienz Herzrhythmusstörungen günstig beeinflussen können. Prospektive, randomisierte,verblindete und kontrollierte konfirmatorische Studien mit ausreichenden Fallzahlen sind jedoch notwendig, um diese Hypothese zu bestätigen.

  4. X-ray findings in the skeleton of the hand to prove renal osteopathy. Soft ray immersions radiography versus standard procedures; Roentgendiagnostik der renalen Osteopathie am Handskelett. Weichstrahl-Immersions-Radiographie kontra Standardtechnik

    Energy Technology Data Exchange (ETDEWEB)

    Pollack, T. [Radiologische Klinik, Krankenhaus Dresden-Friedrichstadt, Staedtisches Klinikum (Germany); Friedberg, R. [Radiologische Klinik, Krankenhaus Dresden-Friedrichstadt, Staedtisches Klinikum (Germany); Heinicke, H.J. [1. Medizinische Klinik, Krankenhaus Dresden-Friedrichstadt, Staedtisches Klinikum (Germany)

    1994-11-01

    In examinations of the hand skeleton, findings typical of renal osteopathy are much more readily revealed by soft ray immersions radiography than by images obtained using conventional techniques. In combination with microradioscopy the method is highly suitable for the primary diagnosis and follow-up of renal osteopathy. The information provided eliminates the need for examinations of other skeletal sections and thus justifies the slightly increased dose requirements. The fact that unchanged parathormone can be determined simultaneously adds to the sensitivity of this non-invasive technique. Histological assessments of the skeleton can, however, not always be avoided. (orig.) [Deutsch] Die Untersuchung des Handskeletts mit Hilfe der Weichstrahl-Immersions-Radiographie (WIR) ist fuer typische Befunde der renalen Osteopathie wesentlich sensitiver als die Aufnahmen in Standardtechnik. In Kombination mit der Mikroradioskopie ist sie fuer die roentgenologische Basisdiagnostik und Verlaufskontrolle der renalen Osteopathie sehr gut geeignet. Der Informationsgewinn und die Moeglichkeit der Einsparung von Roentgenuntersuchungen anderer Skelettabschnitte rechtfertigt den etwas hoeheren Dosisbedarf der WIR. Die gleichzeitige Bestimmung des intakten Parathormons erhoeht die Sensitivitaet der nichtinvasiven Diagnostik. Dennoch laesst sich auf eine Knochenhistologie nicht in jedem Fall verzichten. (orig.)

  5. Radiography With the Patient in the centre

    DEFF Research Database (Denmark)

    Møller, Louise

    2016-01-01

    . Several of these elements have a technical focus. There are relations in an MR scan affecting which actions are included in the scan pathway. However, it is the radiographers who decide which actions to include. Patients and radiographers in this study agreed that center in radiography is about directing......The health care system is becoming more technological, and at the same time, it is verbalized that the patient should be in the center. The purpose of this study was to illucidate how radiography with the patient in the center is performed and what patients and radiographers understand about center...... in radiography. Qualitative methods was used; observations of three MR scans and interviews with three patients and three radiographers are discussed. In the description of an MR scan, it appeared that more elements are involved and that each element has a center of equal importance to complete the MR scan...

  6. Thyroid dose distribution in dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bristow, R.G.; Wood, R.E.; Clark, G.M. (Ontario Cancer Institute, Toronto (Canada))

    1989-10-01

    The anatomic position and proven radiosensitivity of the thyroid gland make it an organ of concern in dental radiography. A calibrated thermoluminescent dosimetry system was used to investigate the absorbed dose (microGy) to the thyroid gland resultant from a minimum irradiated volume, intraoral full-mouth radiography technique with the use of rectangular collimation with a lead-backed image receptor, and conventional panoramic radiography performed with front and rear lead aprons. Use of the minimum irradiated volume technique resulted in a significantly decreased absorbed dose over the entire thyroid region ranging from 100% to 350% (p less than 0.05). Because this intraoral technique results in radiographs with greater image quality and also exposes the thyroid gland to less radiation than the panoramic, this technique may be an alternative to the panoramic procedure.

  7. Digital radiography: a survey of pediatric dentists.

    Science.gov (United States)

    Russo, Julie M; Russo, James A; Guelmann, Marcio

    2006-01-01

    The purpose of this study was to: (1) determine the popularity of digital radiography among members of the American Academy of Pediatric Dentistry (AAPD); and (2) report the most common systems in use. An AAPD-approved, voluntary, and anonymous electronic survey was developed and sent to 923 board certified pediatric dentists. Years in practice and in-office x-ray technology (digital or conventional) were inquired about initially. If negative for the use of digital radiography, future consideration for converting to digital radiography was ascertained. For positive responses, more in-depth information was requested. Information on type of system (sensor or phosphor plate), user friendliness, diagnostic ability, patient's comfort, general costs, durability, and parental and overall satisfaction was collected. For most of the questions, a 5-point assessment scale was used. Opportunity for additional comments was provided upon survey completion. Data was analyzed using descriptive statistics. A 32% (296/923) response rate was obtained. Twenty-six percent of practitioners (78/296) implemented digital radiography in their practices, whereas 71% considered future acquisition. Similar distribution for sensor and phosphor plate users was found. Sensor technology was reported to produce faster images, but was less tolerable by young children due to size and thickness. Phosphor plates were considered more children friendly, less expensive, and less durable. Parental satisfaction was very high with great marketing value. Picture quality was comparable to conventional film. Overall, digital radiography users would recommend it to other pediatric dentists. Digital radiography is not yet popular among pediatric dentists. Cost reduction and technology advancement may enhance utilization.

  8. Proton Radiography: Its uses and Resolution Scaling

    Energy Technology Data Exchange (ETDEWEB)

    Mariam, Fesseha G. [Los Alamos National Laboratory

    2012-08-09

    Los Alamos National Laboratory has used high energy protons as a probe in flash radiography for over a decade. In this time the proton radiography project has used 800 MeV protons, provided by the LANSCE accelerator facility at LANL, to diagnose over five-hundred dynamic experiments in support of stockpile stewardship programs as well as basic materials science. Through this effort significant experience has been gained in using charged particles as direct radiographic probes to diagnose transient systems. The results of this experience will be discussed through the presentation of data from experiments recently performed at the LANL pRad.

  9. Statistical Uncertainty in Quantitative Neutron Radiography

    CERN Document Server

    Piegsa, Florian M

    2016-01-01

    We demonstrate a novel procedure to calibrate neutron detection systems commonly used in standard neutron radiography. This calibration allows determining the uncertainties due to Poisson-like neutron counting statistics for each individual pixel of a radiographic image. The obtained statistical errors are necessary in order to perform correct quantitative analysis. This fast and convenient method is applied to real data measured at the cold neutron radiography facility ICON at the Paul Scherrer Institute. Moreover, from the results the effective neutron flux at the beam line is determined.

  10. Hamlet er manden i mit liv

    DEFF Research Database (Denmark)

    Rösing, Lilian Munk

    2009-01-01

    Hamlet er manden i mit liv. Min elskede. Jeg har en drøm om at frelse ham. At redde ham ud af sin mors soveværelse og ind i mit. Væk fra det ødipale Helvede han befinder sig i, fastlåst mellem et svin af en faderskikkelse (Claudius) og en alt for idealiseret far (gamle Hamlet), vågende over sin...... jeg bare skrige tilbage at han var en håbløs lille Ødipus, og så kunne vi skændes inderligt og forsones ømt. Hamlet er min elskede. Og derfor græder jeg trøstesløst hver gang han dør, hver gang han hengiver sig til det store gruppeorgie af en mordscene hjemme hos mor og far, i stedet for at holde...

  11. MIT Lincoln Laboratory Annual Report 2014

    Science.gov (United States)

    2014-01-01

    Key Partners; Life member, MIT Corporation; Former member, President’s Foreign Intelligence Advisory Board VADM David E. Frost , USN (Ret...President, Frost & Associates, Inc.; Former Deputy Commander, U.S. Space Command Dr. Arthur Gelb President, Four Sigma Corporation; Former Chairman and...Stenbit Former Assistant Secretary of Defense (C3I); Former Executive Vice President, TRW GEN Gordon R. Sullivan , USA (Ret) President of the

  12. Integrierte Produktions- und Distributionsplanung mit Routingentscheidungen

    OpenAIRE

    Wendt, Rolf

    2016-01-01

    Die zentrale Problemstellung dieser Arbeit entstammt dem operationellen Supply Chain Management. Es liegen Bestellungen von Kunden vor, für die jeweils zu entscheiden ist, ob sie angenommen werden sollen. Die angenommenen Bestellungen sind auf einem vorhandenen Maschinenpark zu produzieren und fertiggestellte Bestellungen sind an den jeweiligen Kunden auszuliefern. Zu diesem Zwecke steht eine Transporterflotte bereit, wobei die Auslieferung in der Form "Sammelauslieferung mit Rundreise" erfol...

  13. MIT App Inventor: Enabling Personal Mobile Computing

    OpenAIRE

    Pokress, Shaileen Crawford; Veiga, José Juan Dominguez

    2013-01-01

    MIT App Inventor is a drag-and-drop visual programming tool for designing and building fully functional mobile apps for Android. App Inventor promotes a new era of personal mobile computing in which people are empowered to design, create, and use personally meaningful mobile technology solutions for their daily lives, in endlessly unique situations. App Inventor's intuitive programming metaphor and incremental development capabilities allow the developer to focus on the logic for programming ...

  14. Grundlegende Steuerungsverfahren im heterogenen Logistiknetz mit Kanban

    Science.gov (United States)

    Dickmann, Eva; Dickmann, Philipp; Lödding, Hermann; Möller, Niklas; Rücker, Thomas; Schneider, Herfried M.; Zäh, Michael F.

    In vielen Unternehmen werden heterogene (verschiedene) Steuerungen in einem abgestimmten Konzept kombiniert. Je nach Anwendungsfall und Rahmenbedingungen werden Kombinationen allgemein bekannter Steuerungen oder Steuerungsvarianten gemischt eingesetzt, um eine optimale Steuerung für unterschiedliche Fälle zu erreichen. Hierbei stehen neben den bekannten und weit verbreiteten Methoden, wie Material Requirements Planning (MRP) oder Kanban, auch weniger bekannte oder neue Methoden zur Auswahl, wie die Produktionssteuerung mit dezentraler, bestandsorientierter Fertigungsregelung (DBF). Kanban ist ein simples und effizientes Steuerungskonzept, das in der klassischen Form für spezifische einfache Anwendungsfälle umsetzbar ist. Hochentwickelte Steuerungsalgorithmen können helfen, komplexe Abläufe optimal abzubilden. Mit einer grundlegenden Vereinfachung der Abläufe kann allerdings in vielen Fällen ein wesentlich stärkerer und umfassender Verbesserungseffekt erzielt werden. Die wesentliche Fragestellung sollte folglich lauten: Warum ist der Ablauf nicht mit einer einfachen Steuerung wie Kanban abzubilden? Um die Vorteile des Konzepts auch in untypischen Bereichen anwenden zu können, sind jedoch verschiedene Varianten oder Kanban-ähnliche Steuerungsmethoden entstanden. Darüber hinaus sind in der Praxis hybride Steuerungen im Einsatz, welche so kombiniert werden, dass die Zusammensetzung anspruchsvolle Eigenschaftsbilder noch exakt abbildet. In der Praxis basieren die Steuerungsentscheidungen nur zu einem kleinen Teil auf den eigentlichen Steuerungsalgorithmen, wie sie uns das MRP-System zur Verfügung stellt. Moderne Steuerungswelten" schließen alle relevanten Informationsquellen in eine heterogene Entscheidungsmatrix mit ein. Letztlich zählt nicht, ob die Entscheidung auf den Informationen aus dem MRP-System oder auf Softfacts basierend getroffen wurde, sondern nur, ob die Entscheidung erfolgreich war.

  15. Feline dental radiography and radiology: A primer.

    Science.gov (United States)

    Niemiec, Brook A

    2014-11-01

    Information crucial to the diagnosis and treatment of feline oral diseases can be ascertained using dental radiography and the inclusion of this technology has been shown to be the best way to improve a dental practice. Becoming familar with the techniques required for dental radiology and radiography can, therefore, be greatly beneficial. Novices to dental radiography may need some time to adjust and become comfortable with the techniques. If using dental radiographic film, the generally recommended 'E' or 'F' speeds may be frustrating at first, due to their more specific exposure and image development requirements. Although interpreting dental radiographs is similar to interpreting a standard bony radiograph, there are pathologic states that are unique to the oral cavity and several normal anatomic structures that may mimic pathologic changes. Determining which teeth have been imaged also requires a firm knowledge of oral anatomy as well as the architecture of dental films/digital systems. This article draws on a range of dental radiography and radiology resources, and the benefit of the author's own experience, to review the basics of taking and interpreting intraoral dental radiographs. A simplified method for positioning the tubehead is explained and classic examples of some common oral pathologies are provided. © ISFM and AAFP 2014.

  16. Establishing rigour in qualitative radiography research

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, F.J. [School of Healthcare Professions, University of Salford, Salford M6 6PU (United Kingdom)], E-mail: f.j.murphy@salford.ac.uk; Yielder, J. [Medical Imaging, School of Health Sciences, Unitec, Auckland (New Zealand)

    2010-02-15

    The vast majority of radiography research is subject to critique and evaluation from peers in order to justify the method and the outcome of the study. Within the quantitative domain, which the majority of medical imaging publications tend to fall into, there are prescribed methods for establishing scientific rigour and quality in order to critique a study. However, researchers within the qualitative paradigm, which is a developing area of radiography research, are often unclear about the most appropriate methods to measure the rigour (standards and quality) of a research study. This article considers the issues related to rigour, reliability and validity within qualitative research. The concepts of reliability and validity are briefly discussed within traditional positivism and then the attempts to use these terms as a measure of quality within qualitative research are explored. Alternative methods for research rigour in interpretive research (meanings and emotions) are suggested in order to compliment the existing radiography framework that exists for qualitative studies. The authors propose the use of an established model that is adapted to reflect the iterative process of qualitative research. Although a mechanistic approach to establishing rigour is rejected by many qualitative researchers, it is argued that a guide for novice researchers within a developing research base such as radiography is appropriate in order to establish the credibility and trustworthiness of a qualitative study.

  17. Safety Testing of Industrial Radiography Devices

    Energy Technology Data Exchange (ETDEWEB)

    Trapp, D.J.

    1999-09-29

    The Nuclear Regulatory Commission contracted the Savannah River Technology Center to verify the relevancy of the 10 CFR Part 34 requirements for the normal use of portable gamma radiography systems and to propose recommendations for changes or modifications to the requirements.

  18. Radiography Student Participation in Professional Organizations.

    Science.gov (United States)

    Michael, Kimberly; Tran, Xuan; Keller, Shelby; Sayles, Harlan; Custer, Tanya

    2017-09-01

    To gather data on educational program requirements for student membership in a state or national professional society, organization, or association. A 10-question online survey about student involvement in professional societies was emailed to 616 directors of Joint Review Committee on Education in Radiologic Technology (JRCERT)-accredited radiography programs. A total of 219 responses were received, for a 36% response rate. Of these, 89 respondents (41%) answered that their programs require students to join a professional organization. The society respondents most often required (70%) was a state radiography society. Sixty respondents (68%) answered that students join a society at the beginning of the radiography program (from matriculation to 3 months in). Of programs requiring student membership in professional societies, 42 (49%) reported that their students attend the state or national society annual conference; however, participation in activities at the conferences and in the society throughout the year is lower than conference attendance. Some directors stated that although their programs' policies do not allow membership mandates, they encourage students to become members, primarily so that they can access webinars and other educational materials or information related to the profession. Survey data showed that most JRCERT-accredited radiography programs support but do not require student membership in professional organizations. The data reveal that more programs have added those requirements in recent years. Increased student participation could be realized if programs mandated membership and supported it financially. ©2017 American Society of Radiologic Technologists.

  19. INDUSTRIAL RADIOGRAPHY COURSE, INSTRUCTORS' GUIDE. VOLUME 2.

    Science.gov (United States)

    Texas A and M Univ., College Station. Engineering Extension Service.

    INFORMATION RELATIVE TO THE LESSON PLANS IN "INDUSTRIAL RADIOGRAPHY COURSE, INSTRUCTOR'S GUIDE, VOLUME I" (VT 003 565) IS PRESENTED ON 52 INFORMATION SHEETS INCLUDING THE SUBJECTS SHIELDING EQUATIONS AND LOGARITHMS, METAL PROPERTIES, FIELD TRIP INSTRUCTIONS FOR STUDENTS, WELDING SYMBOLS AND SIZES, SAMPLE REPORT FORMS, AND TYPICAL SHIPPING…

  20. Conditions for radiation protection in industrial radiography

    CERN Document Server

    1999-01-01

    The leaflet specifies radiation protection requirements for industrial radiography in Norway. The regulations are directed towards companies using or distributing sealed radioactive sources, x-ray equipment or accelerators in non-destructive material testing (NDT). Technical requirements to the equipment, as well as administrative requirements for use, licensing, qualifications, handling of accidents etc. are given. (Author)

  1. Comprehensive Optimization Process of Paranasal Sinus Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Saarakkala, S. (Dept. of Clinical Radiology, Kuopio Univ. Hospital, Kuopio (Finland)); Nironen, K.; Hermunen, H.; Aarnio, J.; Heikkinen, J.O. (Dept. of Radiology, Etel-Savo Hospital District, Mikkeli Central Hospital, Mikkeli (Finland))

    2009-04-15

    Background: The optimization of radiological examinations is important in order to reduce unnecessary patient radiation exposure. Purpose: To perform a comprehensive optimization process for paranasal sinus radiography at Mikkeli Central Hospital (Finland). Material and Methods: Patients with suspicion of acute sinusitis were imaged with a Kodak computed radiography (CR) system (n=20) and with a Philips digital radiography (DR) system (n=30) using focus-detector distances (FDDs) of 110 cm, 150 cm, or 200 cm. Patients' radiation exposure was determined in terms of entrance surface dose and dose-area product. Furthermore, an anatomical phantom was used for the estimation of point doses inside the head. Clinical image quality was evaluated by an experienced radiologist, and physical image quality was evaluated from the digital radiography phantom. Results: Patient doses were significantly lower and image quality better with the DR system compared to the CR system. The differences in patient dose and physical image quality were small with varying FDD. Clinical image quality of the DR system was lowest with FDD of 200 cm. Further, imaging with FDD of 150 cm was technically easier for the technologist to perform than with FDD of 110 cm. Conclusion: After optimization, it was recommended that the DR system with FDD of 150 cm should always be used at Mikkeli Central Hospital. We recommend this kind of comprehensive approach in all optimization processes of radiological examinations.

  2. MRI versus radiography of acromioclavicular joint dislocation.

    Science.gov (United States)

    Nemec, Ursula; Oberleitner, Gerhard; Nemec, Stefan F; Gruber, Michael; Weber, Michael; Czerny, Christian; Krestan, Christian R

    2011-10-01

    Acromioclavicular joint injuries are usually diagnosed by clinical and radiographic assessment with the Rockwood classification, which is crucial for treatment planning. In view of the implementation of MRI for visualization of the acromioclavicular joint, the purpose of this study was to describe the MRI findings of acromioclavicular joint dislocation in comparison with the radiographic findings. Forty-four patients with suspected unilateral acromioclavicular joint dislocation after acute trauma were enrolled in this prospective study. All patients underwent digital radiography and 1-T MRI with a surface phased-array coil. MRI included coronal proton density-weighted turbo spin-echo and coronal 3D T1-weighted fast field-echo water-selective sequences. The Rockwood classification was used to assess acromioclavicular joint injuries at radiography and MRI. An adapted Rockwood classification was used for MRI evaluation of the acromioclavicular joint ligaments. The classifications of acromioclavicular joint dislocations diagnosed with radiography and MRI were compared. Among 44 patients with Rockwood type I-IV injuries on radiographs, classification on radiographs and MR images was concordant in 23 (52.2%) patients. At MRI, the injury was reclassified to a less severe type in 16 (36.4%) patients and to a more severe type in five (11.4%) patients. Compared with the findings according to the original Rockwood system, with the adapted system that included MRI findings, additional ligamentous lesions were found in 11 (25%) patients. In a considerable number of patients, the MRI findings change the Rockwood type determined with radiography. In addition to clinical assessment and radiography, MRI may yield important findings on ligaments that may influence management.

  3. Detection of lung nodules. New opportunities in chest radiography; Detektion pulmonaler Rundherde. Neue Moeglichkeiten der Thoraxradiographie

    Energy Technology Data Exchange (ETDEWEB)

    Poetter-Lang, S. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Department of Biomedical Imaging and Image-Guided Therapy, Wien (Austria); Schalekamp, S. [Radboud University Nijmegen Medical Center, Nijmegen (Netherlands); Schaefer-Prokop, C. [Radboud University Nijmegen Medical Center, Nijmegen (Netherlands); Meander Medical Center Amersfoort, Amersfoort (Netherlands); Uffmann, M. [Landesklinikum Neunkirchen, Abteilung fuer Radiodiagnostik, Neunkirchen (Germany)

    2014-05-15

    Chest radiography still represents the most commonly performed X-ray examination because it is readily available, requires low radiation doses and is relatively inexpensive. However, as previously published, many initially undetected lung nodules are retrospectively visible in chest radiographs. The great improvements in detector technology with the increasing dose efficiency and improved contrast resolution provide a better image quality and reduced dose needs. The dual energy acquisition technique and advanced image processing methods (e.g. digital bone subtraction and temporal subtraction) reduce the anatomical background noise by reduction of overlapping structures in chest radiography. Computer-aided detection (CAD) schemes increase the awareness of radiologists for suspicious areas. The advanced image processing methods show clear improvements for the detection of pulmonary lung nodules in chest radiography and strengthen the role of this method in comparison to 3D acquisition techniques, such as computed tomography (CT). Many of these methods will probably be integrated into standard clinical treatment in the near future. Digital software solutions offer advantages as they can be easily incorporated into radiology departments and are often more affordable as compared to hardware solutions. (orig.) [German] Das Thoraxroentgen mit den Vorteilen der schnellen Verfuegbarkeit, geringen Strahlendosis und geringen Kosten ist unveraendert die haeufigste radiologische Untersuchung. Es wurde jedoch vielfach publiziert, dass primaer im Thoraxroentgen uebersehene Lungenrundherde retrospektiv sichtbar waren. Die grossen Fortschritte der Detektortechnologie mit verbesserter Dosiseffizienz und Ortsaufloesung der Systeme fuehren zu einer gesteigerten Bildqualitaet bei geringerem Dosisbedarf. Die Dual-energy-Aufnahmetechnik sowie auch Bildverarbeitungsmethoden wie die digitale Knochensubtraktion und die ''temporal subtraction'' reduzieren das &apos

  4. MIT-Skywalker: On the use of a markerless system.

    Science.gov (United States)

    Goncalves, Rogerio S; Hamilton, Taya; Krebs, Hermano I

    2017-07-01

    This paper describes our efforts to employ the Microsoft Kinect as a low cost vision control system for the MIT-Skywalker, a robotic gait rehabilitation device. The Kinect enables an alternative markerless solution to control the MIT-Skywalker and allows a more user-friendly set-up. A study involving eight healthy subjects and two stroke survivors using the MIT-Skywalker device demonstrates the advantages and challenges of this new proposed approach.

  5. [Bernt Ahrenholz : Verweise mit Demonstrativa im Gesprochenen Deutsch...] / Klaus Geyer

    Index Scriptorium Estoniae

    Geyer, Klaus

    2008-01-01

    Arvustus: Ahrenholz, Bernt. Verweise mit Demonstrativa im gesprochenen Deutsch : Grammatik, Zweitspracherwerb und Deutsch als Fremdsprache. Berlin ; New York : de Gruyter, 2007. (Linguistik - Impulse & Tendenzen ; 17)

  6. [Bernt Ahrenholz : Verweise mit Demonstrativa im Gesprochenen Deutsch...] / Klaus Geyer

    Index Scriptorium Estoniae

    Geyer, Klaus

    2008-01-01

    Arvustus: Ahrenholz, Bernt. Verweise mit Demonstrativa im gesprochenen Deutsch : Grammatik, Zweitspracherwerb und Deutsch als Fremdsprache. Berlin ; New York : de Gruyter, 2007. (Linguistik - Impulse & Tendenzen ; 17)

  7. MIT - Mighty Steps toward Energy Sustainability

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Alastair [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Regnier, Cindy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Settlemyre, Kevin [Sustainable IQ, Inc., Arlington, MA (United States); Bosnic, Zorana [HOK, San Francisco, CA (United States)

    2012-07-01

    Massachusetts Institute of Technology (MIT) partnered with the U.S. Department of Energy (DOE) to develop and implement solutions to retrofit existing buildings to reduce energy consumption by at least 30% as part of DOE’s Commercial Building Partnerships (CBP) Program.1 Lawrence Berkeley National Laboratory (LBNL) provided technical expertise in support of this DOE program. MIT is one of the U.S.’s foremost higher education institutions, occupying a campus that is nearly 100 years old, with a building floor area totaling more than 12 million square feet. The CBP project focused on improving the energy performance of two campus buildings, the Ray and Maria Stata Center (RMSC) and the Building W91 (BW91) data center. A key goal of the project was to identify energy saving measures that could be applied to other buildings both within MIT’s portfolio and at other higher education institutions. The CBP retrofits at MIT are projected to reduce energy consumption by approximately 48%, including a reduction of around 72% in RMSC lighting energy and a reduction of approximately 55% in RMSC server room HVAC energy. The energy efficiency measure (EEM) package proposed for the BW91 data center is expected to reduce heating, ventilation, and air-conditioning (HVAC) energy use by 30% to 50%, depending on the final air intake temperature that is established for the server racks. The RMSC, an iconic building designed by Frank Gehry, houses the Computer Science and Artificial Intelligence Laboratory, the Laboratory for Information and Decision Systems, and the Department of Linguistics and Philosophy.

  8. Real-Time Neutron Radiography at CARR

    Institute of Scientific and Technical Information of China (English)

    HE; Lin-feng; HAN; Song-bai; WANG; Hong-li; WU; Mei-mei; WEI; Guo-hai; WANG; Yu

    2012-01-01

    <正>A real-time detector system for neutron radiography based on CMOS camera has been designed for the thermal neutron imaging facility under construction at China Advanced Research Reactor (CARR). This system is equipped with a new scientific CMOS camera with 5.5 million pixels and speed up to 100 fps at full frame. The readout noise is less than 2.4 electron per pixel. It is capable of providing

  9. Assessment of cold neutron radiography capability

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, T.E. Jr.; Roberts, J.A.

    1998-12-31

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The authors goals were to demonstrate and assess cold neutron radiography techniques at the Los Alamos Neutron Science Center (LANSCE), Manual Lujan Neutron Scattering Center (Lujan Center), and to investigate potential applications of the capability. The authors have obtained images using film and an amorphous silicon detector. In addition, a new technique they have developed allows neutron radiographs to be made using only a narrow range of neutron energies. Employing this approach and the Bragg cut-off phenomena in certain materials, they have demonstrated material discrimination in radiography. They also demonstrated the imaging of cracks in a sample of a fire-set case that was supplied by Sandia National Laboratory, and they investigated whether the capability could be used to determine the extent of coking in jet engine nozzles. The LANSCE neutron radiography capability appears to have applications in the DOE stockpile maintenance and science-based stockpile stewardship (SBSS) programs, and in industry.

  10. Digital radiography: image quality and radiation dose.

    Science.gov (United States)

    Seibert, J Anthony

    2008-11-01

    Digital radiography devices, rapidly replacing analog screen-film detectors, are now common in diagnostic radiological imaging, where implementation has been accelerated by the commodity status of electronic imaging and display systems. The shift from narrow latitude, fixed-speed screen-film detectors to wide latitude, variable-speed digital detectors has created a flexible imaging system that can easily result in overexposures to the patient without the knowledge of the operator, thus potentially increasing the radiation burden of the patient population from radiographic examinations. In addition, image processing can be inappropriately applied causing inconsistent or artifactual appearance of anatomy, which can lead to misdiagnosis. On the other hand, many advantages can be obtained from the variable-speed digital detector, such as an ability to lower dose in many examinations, image post-processing for disease-specific conditions, display flexibility to change the appearance of the image and aid the physician in making a differential diagnosis, and easy access to digital images. An understanding of digital radiography is necessary to minimize the possibility of overexposures and inconsistent results, and to achieve the principle of as low as reasonably achievable (ALARA) for the safe and effective care of all patients. Thus many issues must be considered for optimal implementation of digital radiography, as reviewed in this article.

  11. Bacteriological research for the contamination of equipment in chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seung Gu; Song, Woon Heung; Kweon, Dae Cheol [Shinhan University, Uijeongbu (Korea, Republic of)

    2015-12-15

    The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections.

  12. The Enhanced Workflow and Efficiency of the Wireless Local Area Network (WLAN)-Based Direct Digital Radiography (DDR) Portable Radiography.

    Science.gov (United States)

    Ngan, Tsz-Lung; Wong, Edward Ting-Hei; Ng, Kris Lap-Shun; Jeor, Patrick Kwok-Shing; Lo, Gladys Goh

    2015-06-01

    With the implementation of the PACS in the hospital, there is an increasing demand from the clinicians for immediate access and display of radiological images. Recently, our hospital has installed the first wireless local area network (WLAN)-based direct digital radiography (DDR) portable radiography system. The DDR portable radiography system allows wireless retrieval of modality worklist and wireless transmission of portable X-ray image on the console to the Picture Archiving and Communication System (PACS), via WLAN connection of wireless fidelity (Wi-Fi). The aim of this study was to analyze the workflow and performance between the WLAN-based DDR portable radiography system and the old practice using conventional portable X-ray machine with computed radiography (CR) system. A total of 190 portable chest X-ray examinations were evaluated and timed, using the conventional portable X-ray machine with CR from March to April of 2012 and using the new DDR portable radiography system on December of 2012 (n = 97 for old system and n = 93 for DDR portable system). The time interval of image becoming available to the PACS using the WLAN-based DDR portable radiography system was significantly shorter than that of the old practice using the conventional portable X-ray machine with CR (6.8 ± 2.6 min for DDR portable system; 23 ± 10.2 min for old system; p DDR portable radiography system can enhance the workflow of portable radiography by reduction of procedural steps.

  13. Dentinhaftung von Zementen. Der Haftverbund von Zementen mit Dentin in Kombination mit verschiedenen indirekten Restaurationsmaterialien

    OpenAIRE

    Peutzfeldt, Anne; Sahafi, Alireza; Flury, Simon

    2011-01-01

    Einleitung: Die Anzahl zahnärztlicher Zemente sowie Restaurationsmaterialien steigt stetig. Die richtige Zementwahl für einen zuverlässigen Haftverbund zwischen Restaurationsmaterial und Zahnsubstanz ist von Interesse für den Kliniker. Ziel der vorliegenden in vitro-Studie war es daher, den Dentinhaftverbund von verschiedenen Zementen in Kombination mit verschiedenen indirekten Restaurationsmaterialien zu untersuchen. Material und Methoden: Zylindrische Probekörper aus sechs Restaurations...

  14. Teaching ``The Physics of Energy'' at MIT

    Science.gov (United States)

    Jaffe, Robert

    2009-05-01

    New physics courses on energy are popping up at colleges and universities across the country. Many require little or no previous physics background, aiming to introduce a broad audience to this complex and critical problem, often augmenting the scientific message with economic and policy discussions. Others are advanced courses, focussing on highly specialized subjects like solar voltaics, nuclear physics, or thermal fluids, for example. About two years ago Washington Taylor and I undertook to develop a course on the ``Physics of Energy'' open to all MIT students who had taken MIT's common core of university level calculus, physics, and chemistry. By avoiding higher level prerequisites, we aimed to attract and make the subject relevant to students in the life sciences, economics, etc. --- as well as physical scientists and engineers --- who want to approach energy issues in a sophisticated and analytical fashion, exploiting their background in calculus, mechanics, and E & M, but without having to take advanced courses in thermodynamics, quantum mechanics, or nuclear physics beforehand. Our object was to interweave teaching the fundamental physics principles at the foundations of energy science with the applications of those principles to energy systems. We envisioned a course that would present the basics of statistical, quantum, and fluid mechanics at a fairly sophisticated level and apply those concepts to the study of energy sources, conversion, transport, losses, storage, conservation, and end use. In the end we developed almost all of the material for the course from scratch. The course debuted this past fall. I will describe what we learned and what general lessons our experience might have for others who contemplate teaching energy physics broadly to a technically sophisticated audience.

  15. Computed radiography in an emergency department setting

    Science.gov (United States)

    Andriole, Katherine P.; Gould, Robert G.; Arenson, Ronald L.

    1997-05-01

    Evaluation of radiologist and non-radiologist physician acceptance of computed radiography (CR) as an alternative to film-based radiography in an emergency department (ED) is performed. All emergency department radiographs are performed using photostimulable phosphor plates and rad by a computed radiography laser reader placed in the former emergency department darkroom. Soft copy images are simultaneously transmitted to high- and medium-resolution dual-monitor display stations located in radiology and ED reading rooms respectively. The on-call radiologist is automatically paged by the Radiology Information System (RIS) upon exam completion, to read the new ED imaging study. Patient demographic information including relevant clinical history is conveyed to the radiologist via the RIS. A 'wet read' preliminary radiology report is immediately transmitted back to the ED. Radiology and ED physicians are surveyed to ascertain preferences for CR or traditional screen-film, based on system implementation, image viewing and clinical impact issues. Preliminary results indicate a preference for filmless CR among the ED physicians if digital reliability and speed issues are met. This preference appears to be independent of physician level of experience. Inexperienced radiologists-in-training appear to have less comfort with softcopy reading for primary diagnosis. However, additional training in softcopy reading techniques can improve confidences. Image quality issues are most important tot he radiologist, while speed and reliability are the major issues for ED physicians. Reasons for CR preference include immediate access to images on display stations, near-zero exam retake rates, and improved response time and communication between radiology and the emergency department clinician.

  16. Axial Tomography from Digitized Real Time Radiography

    Science.gov (United States)

    Zolnay, A. S.; McDonald, W. M.; Doupont, P. A.; McKinney, R. L.; Lee, M. M.

    1985-01-18

    Axial tomography from digitized real time radiographs provides a useful tool for industrial radiography and tomography. The components of this system are: x-ray source, image intensifier, video camera, video line extractor and digitizer, data storage and reconstruction computers. With this system it is possible to view a two dimensional x-ray image in real time at each angle of rotation and select the tomography plane of interest by choosing which video line to digitize. The digitization of a video line requires less than a second making data acquisition relatively short. Further improvements on this system are planned and initial results are reported.

  17. Digital Radiography Qualification of Tube Welding

    Science.gov (United States)

    Carl, Chad

    2012-01-01

    The Orion Project will be directing Lockheed Martin to perform orbital arc welding on commodities metallic tubing as part of the Multi Purpose Crew Vehicle assembly and integration process in the Operations and Checkout High bay at Kennedy Space Center. The current method of nondestructive evaluation is utilizing traditional film based x-rays. Due to the high number of welds that are necessary to join the commodities tubing (approx 470), a more efficient and expeditious method of nondestructive evaluation is desired. Digital radiography will be qualified as part of a broader NNWG project scope.

  18. Digital radiography in the aerospace industry

    Science.gov (United States)

    Buchanan, R. A.; Bueno, C.; Barry, R. C.; Barker, M. D.

    An account is given of the bases of digital radiography (DR), with a view to the identification of NDE systems with the greatest usefulness to the aerospace industry and the nature of the advanced image processing and reconstruction techniques that have been devised thus far. The spatial resolution of any DR system is fundamentally limited by the number of pixels in the digital image and the system field-of-view. Attention is given to the problems of image geometric unsharpness and radiation quantum noise limits, as well as to the potential role of advanced DR in future NDT of aerospace components.

  19. Screening for lung cancer with low-dose computed tomography; Bronchialkarzinom-Screening mit Niedrigdosis-CT. Aktueller Stand

    Energy Technology Data Exchange (ETDEWEB)

    Diederich, S.; Wormanns, D.; Heindel, W. [Muenster Univ. (Germany). Inst. fuer Klinische Radiologie

    2001-03-01

    Lung cancer is the most common cause of death from malignancy. It is characterized by a favourable prognosis when treated in early stages and a poor prognosis in advanced stages. Populations at risk are relatively well defined, i.e. heavy smokers and workers exposed to asbestos and radon. Therefore, early detection using diagnostic techniques promises reduction of mortality from this tumor. Previous studies using chest radiography and sputum cytology were, however, disappointing due to poor sensitivity of these tests for early tumor stages. The new technique of low-dose computed tomography provides both high sensitivity for small tumors and a comfortable examination. As small benign pulmonary nodules are common reliable non-invasive diagnostic algorithms are required for classification of nodules. Preliminary studies using low-dose CT screening in smokers have provided promising results. Prior to a wide application of the technique in clinical routine more data are required as to inclusion criteria, examination intervals and the effect of screening on mortality reduction. (orig.) [German] Das Bronchialkarzinom ist der am haeufigsten zum Tode fuehrende maligne Tumor. Seine Prognose ist bei einer Therapie in fruehen Stadien relativ gut, in fortgeschrittenen Erkrankungsstadien dagegen ausgesprochen schlecht. Die Risikopopulationen sind gut charakterisiert, v.a. starke Raucher und Personen mit einer beruflichen Asbest- bzw. Radonexposition. Vor diesem Hintergrund erscheinen Frueherkennungsuntersuchungen mittels diagnostischer Verfahren sinnvoll, um die Sterblichkeit an diesem Tumor zu senken. Bisherige Erfahrungen mit Thoraxroentgenaufnahmen und Sputumuntersuchungen waren aufgrund der geringen Sensitivitaet der Verfahren fuer fruehe Tumorstadien jedoch enttaeuschend. Das relativ neue Verfahren der Niedrigdosis-Computertomographie des Thorax verbindet eine hohe Sensitivitaet fuer kleine Tumoren mit einer geringen Belastung der untersuchten Person. Wegen der Haeufigkeit

  20. Preliminary Study of Indirect Neutron Radiography Method at CARR

    Institute of Scientific and Technical Information of China (English)

    WEI; Guo-hai; HAN; Song-bai; WANG; Hong-li; HE; Lin-feng; WANG; Yu; WU; Mei-mei; LIU; Yun-tao; CHEN; Dong-feng

    2013-01-01

    The Indirect Neutron Radiography is a powerful technique for non-destructively measuring specimens with radioactivity in the nuclear industrial field.China Advanced Research Reactor(CARR)is an excellent platform for Indirect Neutron Radiography and the experimental conditions based on CARR,mainly the first and the second exposure time,have been calculated and analyzed by the Monte Carlo

  1. Development of analyzing techniques for an active stability enhancement based on wavelet schemes. Final report; CO{sub 2}-armes Kraftwerk - 500 MW auf einer Welle. Vorhaben 1.1.7: Weiterentwicklung von Analyseverfahren zur aktiven Stabilitaetsverbesserung mit Schwerpunkt Wavelet-Methode. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Rick, H.; Erhard, W.; Uhlmann, H.G.

    2001-07-01

    The effective operational range of turbocompressors is primarily restricted by the surge line. As crossing this line may lead to a catastrophic failure of the complete system, modern conventionally designed compressors operate with a sufficient stability reserve with the consequence of losses in pressure ratio and overall efficiency. The aim of this project is the further development of a wavelet based analysis technique for detecting a critical approach to the surge line as early as possible to ensure a safe operation even with a reduced surge margin. The new technique combines a simple discrete wavelet transform of two circumferential pressure sensors in front of the first rotor with a wavelet packet transform. The resulting spectrum is observed at certain frequencies, whereby exceeding the amplitude-threshold causes a stall warning. The results are similar to these of the ''traveling wave energy'' method by Tryfonidis, but with much less measurement instrumentation requirements. Thus, after validating the applicability to different types of compressors the new analyzing technique could be assigned to commercial gas turbines and aero engines without great effort. (orig.) [German] Der nutzbare Arbeitsbereich von Turboverdichtern ist in erster Linie durch die Pumpgrenze beschraenkt. Da deren Ueberschreiten zu einem katastrophalen Ausfall der Gesamtanlage fuehren kann, operieren heutige Verdichter bei konventioneller Auslegung mit einem entsprechend grossen Pumpgrenzabstand, wodurch Einbussen bezueglich Druckverhaeltnis und Wirkungsgrad in Kauf genommen werden muessen. Ziel des Vorhabens ist es, ein Waveletanalyseverfahren weiterzuentwickeln, das eine kritische Annaeherung an die Pumpgrenze fruehzeitig erkennt, so dass auch bei reduzierter Pumpgrenzabstand ein sicherer Betrieb gewaehrleistet werden kann. Das neue Verfahren kombiniert eine einfache diskrete Wavelettransformation zweier Drucksensoren am Umfang vor dem ersten Laufrad mit einer

  2. Digital radiography of the chest in pediatric patients; Die digitale Thoraxradiographie beim paediatrischen Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Puig, S. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria)

    2003-12-01

    The hopes placed in digital radiography have been fulfilled only partly in pediatric radiology. Specifically, the option of gaining reduced radiation exposure in combination with a similar or even improved image quality was hard to realize. The only portable digital system available for a long time were storage phosphors which were disadvantaged by an extremely limited dose-quantum-efficiency (DQE) in comparison to digital flat panel detectors. New developments and the introduction of the dual-reading system led to image qualities comparable to film-screen-systems with high resolution and achievable without dose increase, sometimes even with dose reduction. A study using an animal model suggests that these systems can even be used in preterm infants with very low birth weights. A new portable flat panel detector by Canon may improve digital chest radiography in pediatric patients. (orig.) [German] Erwartungen, die man anfaenglich in die digitale Projektionsradiographie gesetzt hat, haben sich in der Kinderradiologie erst verzoegert oder teilweise gar nicht erfuellt. Insbesondere Hoffnungen, dass man die Strahlenbelastung bei gleich bleibender oder gar verbesserter Bildqualitaet reduzieren koennte, wurden bald enttaeuscht. Das einzige portable digitale System waren lange Zeit Phosphorplatten, die aber im Vergleich zu den Festplattendetektoren eine aeusserst limitierte Dosisquanteneffizienz (DQE) hatten. Durch neue Entwicklungen und v. a. durch die Einfuehrung des Dual-reading-Systems kann eine Bildqualitaet erreicht werden, die an hochaufloesende Film-Folien-Systeme heranreicht, ohne die Dosis erhoehen zu muessen. Teilweise ist nun auch eine Dosisreduktion moeglich. In einem Tiermodell konnte gezeigt werden, dass diese Systeme auch bei Fruehgeborenen mit einem sehr niedrigen Geburtgewicht einsetzbar sind. Hoffnung wird in ein neues portables Festplattendetektorsystem gesetzt, welches in der paediatrischen digitalen Thoraxradiographie evtl. neue Massstaebe setzen

  3. Initial results from a multiple monoenergetic gamma radiography system for nuclear security

    Science.gov (United States)

    O'Day, Buckley E.; Hartwig, Zachary S.; Lanza, Richard C.; Danagoulian, Areg

    2016-10-01

    The detection of assembled nuclear devices and concealed special nuclear materials (SNM) such as plutonium or uranium in commercial cargo traffic is a major challenge in mitigating the threat of nuclear terrorism. Currently available radiographic and active interrogation systems use ∼1-10 MeV bremsstrahlung photon beams. Although simple to build and operate, bremsstrahlung-based systems deliver high radiation doses to the cargo and to potential stowaways. To eliminate problematic issues of high dose, we are developing a novel technique known as multiple monoenergetic gamma radiography (MMGR). MMGR uses ion-induced nuclear reactions to produce two monoenergetic gammas for dual-energy radiography. This allows us to image the areal density and effective atomic number (Zeff) of scanned cargo. We present initial results from the proof-of-concept experiment, which was conducted at the MIT Bates Research and Engineering Center. The purpose of the experiment was to assess the capabilities of MMGR to measure areal density and Zeff of container cargo mockups. The experiment used a 3.0 MeV radiofrequency quadrupole accelerator to create sources of 4.44 MeV and 15.11 MeV gammas from the 11B(d,nγ)12C reaction in a thick natural boron target; the gammas are detected by an array of NaI(Tl) detectors after transmission through cargo mockups . The measured fluxes of transmitted 4.44 MeV and 15.11 MeV gammas were used to assess the areal density and Zeff. Initial results show that MMGR is capable of discriminating the presence of high-Z materials concealed in up to 30 cm of iron shielding from low- and mid-Z materials present in the cargo mockup.

  4. Simulation of computed radiography with imaging plate detectors

    Energy Technology Data Exchange (ETDEWEB)

    Tisseur, D.; Costin, M. [CEA LIST, CEA Saclay 91191 Gif sur Yvette Cedex (France); Mathy, F. [CEA-LETI, Campus Minatec, F-38054, Grenoble (France); Schumm, A. [EDF R and D, 1 avenue du général de gaulle 92141 Clamart (France)

    2014-02-18

    Computed radiography (CR) using phosphor imaging plate detectors is taking an increasing place in Radiography Testing. CR uses similar equipment as conventional radiography except that the classical X-ray film is replaced by a numerical detector, called image plate (IP), which is made of a photostimulable layer and which is read by a scanning device through photostimulated luminescence. Such digital radiography has already demonstrated important benefits in terms of exposure time, decrease of source energies and thus reduction of radioprotection area besides being a solution without effluents. This paper presents a model for the simulation of radiography with image plate detectors in CIVA together with examples of validation of the model. The study consists in a cross comparison between experimental and simulation results obtained on a step wedge with a classical X-ray tube. Results are proposed in particular with wire Image quality Indicator (IQI) and duplex IQI.

  5. Digital radiography image quality: image processing and display.

    Science.gov (United States)

    Krupinski, Elizabeth A; Williams, Mark B; Andriole, Katherine; Strauss, Keith J; Applegate, Kimberly; Wyatt, Margaret; Bjork, Sandra; Seibert, J Anthony

    2007-06-01

    This article on digital radiography image processing and display is the second of two articles written as part of an intersociety effort to establish image quality standards for digital and computed radiography. The topic of the other paper is digital radiography image acquisition. The articles were developed collaboratively by the ACR, the American Association of Physicists in Medicine, and the Society for Imaging Informatics in Medicine. Increasingly, medical imaging and patient information are being managed using digital data during acquisition, transmission, storage, display, interpretation, and consultation. The management of data during each of these operations may have an impact on the quality of patient care. These articles describe what is known to improve image quality for digital and computed radiography and to make recommendations on optimal acquisition, processing, and display. The practice of digital radiography is a rapidly evolving technology that will require timely revision of any guidelines and standards.

  6. Stochastic noise characteristics in matrix inversion tomosynthesis (MITS).

    Science.gov (United States)

    Godfrey, Devon J; McAdams, H P; Dobbins, James T Third

    2009-05-01

    Matrix inversion tomosynthesis (MITS) uses known imaging geometry and linear systems theory to deterministically separate in-plane detail from residual tomographic blur in a set of conventional tomosynthesis ("shift-and-add") planes. A previous investigation explored the effect of scan angle (ANG), number of projections (N), and number of reconstructed planes (NP) on the MITS impulse response and modulation transfer function characteristics, and concluded that ANG = 20 degrees, N = 71, and NP = 69 is the optimal MITS imaging technique for chest imaging on our prototype tomosynthesis system. This article examines the effect of ANG, N, and NP on the MITS exposure-normalized noise power spectra (ENNPS) and seeks to confirm that the imaging parameters selected previously by an analysis of the MITS impulse response also yield reasonable stochastic properties in MITS reconstructed planes. ENNPS curves were generated for experimentally acquired mean-subtracted projection images, conventional tomosynthesis planes, and MITS planes with varying combinations of the parameters ANG, N, and NP. Image data were collected using a prototype tomosynthesis system, with 11.4 cm acrylic placed near the image receptor to produce lung-equivalent beam hardening and scattered radiation. Ten identically acquired tomosynthesis data sets (realizations) were collected for each selected technique and used to generate ensemble mean images that were subtracted from individual image realizations prior to noise power spectra (NPS) estimation. NPS curves were normalized to account for differences in entrance exposure (as measured with an ion chamber), yielding estimates of the ENNPS for each technique. Results suggest that mid- and high-frequency noise in MITS planes is fairly equivalent in magnitude to noise in conventional tomosynthesis planes, but low-frequency noise is amplified in the most anterior and posterior reconstruction planes. Selecting the largest available number of projections (N

  7. Final Technical Report for the MIT Annular Fuel Research Project

    Energy Technology Data Exchange (ETDEWEB)

    Mujid S. Kazimi; Pavel Hejzlar

    2008-01-31

    MIT-NFC-PR-082 (January 2006) Abstract This summary provides an overview of the results of the U.S. DOE funded NERI (Nuclear Research ENergy Initiative) program on development of the internally and externally cooled annular fuel for high power density PWRs. This new fuel was proposed by MIT to allow a substantial increase in poer density (on the order of 30% or higher) while maintaining or improving safety margins. A comprehensive study was performed by a team consisting of MIT (lead organization), Westinghuse Electric Corporation, Gamma Engineering Corporation, Framatome ANP(formerly Duke Engineering) and Atomic Energy of Canada Limited.

  8. Hämodynamische Analyse und Klassifikation der Gefäßstrukturen bei Patienten mit zerebralen arteriovenösen Malformationen

    Directory of Open Access Journals (Sweden)

    Möller, Dietmar

    2009-08-01

    Datensätze von Patienten mit diagnostizierter AVM zur Verfügung. Durch Anwendung der neuen Methode zur Beschreibung der Einströmzeitpunkte konnten Artefakte in Form von starken zeitlichen Sprüngen zwischen den Einflusszeitpunkten benachbarter Voxel deutlich verringert werden. Die Detektion des Nidus wurde anhand von manuellen Segmentierungen validiert und ergab eine mittlere Volumenübereinstimmung von ca. 88%. Drainagevenen und Feeder konnten mit einer Genauigkeit von 95% detektiert werden. Schlussfolgerung: Die vorgestellte Methode ermöglicht eine robuste automatische Detektion des AVM-Nidus sowie eine Klassifikation der Gefäße. Eine visuelle Begutachtung durch erfahrene Neuroradiologen ergab, dass bei Verwendung der vorgestellten Methode zur Charakterisierung des Blutflusses mittels referenzbasierter Kurvenanpassung dieser besser dargestellt werden kann, als bei der Verwendung konventioneller Parameter. Die Detektion von zuleitenden und ableitenden Gefäßen unterstützt den Mediziner bei der räumlichen Beurteilung der arteriovenösen Malformation. Die Detektion der „en passage“-Gefäße ist besonders hinsichtlich der Planung von neurochirurgischen Eingriffen von hoher Bedeutung.

  9. Nuclear track radiography of 'hot' aerosol particles

    CERN Document Server

    Boulyga, S F; Kievets, M K; Lomonosova, E M; Zhuk, I V; Yaroshevich, O I; Perelygin, V P; Petrova, R I; Brandt, R; Vater, P

    1999-01-01

    Nuclear track radiography was applied to identify aerosol 'hot' particles which contain elements of nuclear fuel and fallout after Chernobyl NPP accident. For the determination of the content of transuranium elements in radioactive aerosols the measurement of the alpha-activity of 'hot' particles by SSNTD was used in this work, as well as radiography of fission fragments formed as a result of the reactions (n,f) and (gamma,f) in the irradiation of aerosol filters by thermal neutrons and high energy gamma quanta. The technique allowed the sizes and alpha-activity of 'hot' particles to be determined without extracting them from the filter, as well as the determination of the uranium content and its enrichment by sup 2 sup 3 sup 5 U, sup 2 sup 3 sup 9 Pu and sup 2 sup 4 sup 1 Pu isotopes. Sensitivity of determination of alpha activity by fission method is 5x10 sup - sup 6 Bq per particle. The software for the system of image analysis was created. It ensured the identification of track clusters on an optical imag...

  10. Clinical Applications of Reverse Panoramic Radiography

    Directory of Open Access Journals (Sweden)

    Sujatha S Reddy

    2011-09-01

    Full Text Available The essence of oral and maxil-lofacial radiology is not only to be an important tool in the diagnostic assessment of dental patients but also to equip the clinician with the ability to interpret images of certain maxillocraniofacial structures of importance to dental, medical and surgical practices. Although combinations of several conven-tional x-ray projections can be adequate in a number of clinical situations, radiographic assessment of certain craniofacial structures some-times needs to be facilitated by other imaging modalities. A not-so-recent development called reverse panoramic radiography may be a useful adjuvant to such a situation, at least in the near future. It is essentially a technique where the patient is placed backwards in the panoramic machine in a reverse position in such a way that x-ray beam is directed through the patient’s face and the exit beam then passes through the patient’s head on the opposite side where it is captured on the receptor. The following manuscript is an attempt to throw light on this technique and the impact it may have on dental, medical and surgical practices. The advantages and disadvantages of reverse panoramic radiography and it’s comparison to conventional panoramic radiographs and other skull views are also dis-cussed.

  11. High Brightness Neutron Source for Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Cremer, J. T.; Piestrup, Melvin, A.; Gary, Charles, K.; Harris, Jack, L. Williams, David, J.; Jones, Glenn, E.; Vainionpaa, J. , H.; Fuller, Michael, J.; Rothbart, George, H.; Kwan, J., W.; Ludewigt, B., A.; Gough, R.., A..; Reijonen, Jani; Leung, Ka-Ngo

    2008-12-08

    This research and development program was designed to improve nondestructive evaluation of large mechanical objects by providing both fast and thermal neutron sources for radiography. Neutron radiography permits inspection inside objects that x-rays cannot penetrate and permits imaging of corrosion and cracks in low-density materials. Discovering of fatigue cracks and corrosion in piping without the necessity of insulation removal is possible. Neutron radiography sources can provide for the nondestructive testing interests of commercial and military aircraft, public utilities and petrochemical organizations. Three neutron prototype neutron generators were designed and fabricated based on original research done at the Lawrence Berkeley National Laboratory (LBNL). The research and development of these generators was successfully continued by LBNL and Adelphi Technology Inc. under this STTR. The original design goals of high neutron yield and generator robustness have been achieved, using new technology developed under this grant. In one prototype generator, the fast neutron yield and brightness was roughly 10 times larger than previously marketed neutron generators using the same deuterium-deuterium reaction. In another generator, we integrate a moderator with a fast neutron source, resulting in a high brightness thermal neutron generator. The moderator acts as both conventional moderator and mechanical and electrical support structure for the generator and effectively mimics a nuclear reactor. In addition to the new prototype generators, an entirely new plasma ion source for neutron production was developed. First developed by LBNL, this source uses a spiral antenna to more efficiently couple the RF radiation into the plasma, reducing the required gas pressure so that the generator head can be completely sealed, permitting the possible use of tritium gas. This also permits the generator to use the deuterium-tritium reaction to produce 14-MeV neutrons with increases

  12. MIT gets good marks for fighting gender discrimination

    Science.gov (United States)

    Gwynne, Peter

    2011-05-01

    The Massachusetts Institute of Technology (MIT) has made "significant progress" in increasing the number of female faculty members, with their numbers in science and engineering almost doubling over the last decade.

  13. Nichterkennen von Vorhofflimmern bei Patienten mit kardialer Resynchronisationstherapie

    Directory of Open Access Journals (Sweden)

    Strohmer B

    2005-01-01

    Full Text Available Obwohl eine Intoleranz der kardialen Resynchronisationstherapie (CRT unüblich ist, sollten entsprechende Symptome auf ihre Ursache hin genau abgeklärt werden. Atriale Tachyarrhythmien (AT werden bei Patienten mit chronischer Herzinsuffizienz relativ häufig beobachtet. Dieser Bericht beschreibt ein rhythmologisches Problem, welches oft unerkannt bleibt und in unserem CRTKollektiv bei knapp 8 % der Patienten aufgetreten ist. Paroxysmales Vorhofflattern wurde durch den CRT-Schrittmacher nicht erkannt, da jede zweite Flatterwelle exakt mit der atrialen Ausblendzeit (PVAB = postventrikuläres atriales Blanking zusammenfiel. Dies führte zu einem Versagen der Mode-Switch-Funktion durch Nichterkennung von stabilem Vorhofflattern, welches mit sehr stabiler Zykluslänge auftrat. Dieses sog. "2:1-lock-in"-Phänomen resultierte in rascher und anhaltender biventrikulärer Stimulation, welche sich bei den betroffenen Patienten klinisch als unangenehmes Herzklopfen mit zunehmender Atemnot bemerkbar machte.

  14. Russisch: Weltsprache mit Trauma - gleichberechtigte Sprache im FMF

    OpenAIRE

    Schröder, Konrad

    1998-01-01

    Russisch: Weltsprache mit Trauma - gleichberechtigte Sprache im FMF. - In: Russisch in den alten und neuen Bundesländern / Bernhard Frenzel ... (Hrsg.). - Berlin ; München : Langenscheidt, 1998. - S. 5-8. - (Fachverband Moderne Fremdsprachen: FMF-Schriften ; 2)

  15. Entwicklung einer Spurendriftkammer mit Mikrostreifenauslese für Schwerionenexperimente

    OpenAIRE

    Frankenfeld, Ulrich

    1996-01-01

    Im Rahmen dieser Arbeit wurde ein Prototyp einer Spurendriftkammer mit Mikrostreifenauslese, wie sie als hochauflösende Spurendetektoren in der Kern- und Teilchenphysik zum Einsatz kommen sollen, konstruiert und getestet. Besonderes Augenmerk lag hierbei auf der Signalform und -verteilung, sowie auf dem Langzeitverhalten. Für die verschiedenen Messungen dieser Arbeit wurden die Mikrostreifen-Gasdetektoren in ein Edelstahlrohr eingebaut, das mit einem Vakuumpumpen-System verbunden ist. Durch E...

  16. Therapie mit Vitamin D: Gibt es Grenzen?

    Directory of Open Access Journals (Sweden)

    Scharla SH

    2014-01-01

    Full Text Available Vitamin D wird in der Leber zum 25-Hydroxyvitamin D umgewandelt, welches die Speicherform darstellt. Die Serumkonzentration von 25-Hydroxyitamin D ist ein Maß für die Vitamin- D-Versorgung. In der Niere wird die Hormonform von Vitamin D, das 1,25-Dihydroxyvitamin D (= Calcitriol oder D-Hormon, hergestellt (endokrine Funktion, aber auch einige extrarenale Gewebe können Calcitriol lokal bilden (autokrine und parakrine Wirkung. Calcitriol hat pleiotrope Effekte: Neben dem Mineralhaushalt werden auch Immunsystem, Zelldifferenzierung, Insulinwirkung und kardiovaskuläres System beeinflusst. Die Therapie mit Vitamin D wird deshalb heute nicht nur zur Behandlung von Störungen des Mineralhaushaltes, sondern auch zur Prävention und Therapie von Infektionen, Autoimmunerkrankungen, Krebs, Bluthochdruck und Herzerkrankungen propagiert. Derzeit fehlen jedoch noch vielfach kontrollierte Studien, die den Nutzen einer Vitamin-D-Behandlung außerhalb von Risikogruppen nachweisen oder die prophylaktische Vitamin-D-Supplementation der allgemeinen Bevölkerung rechtfertigen würden. Überdies ist Vorsicht bei zu hohen Dosierungen geboten, da hohe Vitamin-D-Konzentrationen möglicherweise auch negative Effekte haben können. Die Anwendung einer Vitamin-D-Stoßtherapie (hohe Einmaldosierung ist obsolet.

  17. Rigiscan®-Monitoring der Erektion unter audiovisueller sexueller Stimulation ohne/mit Viagra™ bei Patienten mit erektiler Dysfunktion

    Directory of Open Access Journals (Sweden)

    Perabo FGE

    2000-01-01

    Full Text Available Die orale Medikation mit Sildenafil (Viagra™ hat sich zur Therapie der erektilen Dysfunktion etabliert und relativiert die Differentialdiagnose zwischen psychogener und organischer Dysfunktion mit den entsprechenden therapeutischen Konsequenzen. Diesem Problem widmet sich diese Studie zur Prüfung der erektilen Antwort unter RigiScan®-Monitoring ohne/mit 50 mg Viagra™. 64 Patienten (mittleres Alter 48 Jahre mit einer erektilen Dysfunktion arteriogener (n = 10, venöser (n = 7, gemischt neurogen/vaskulärer (n = 15 und psychogener (n = 32 Genese von mehr als 6 Monaten Dauer wurden in die Studie aufgenommen. Alle Patienten wurden eingehend diagnostisch abgeklärt, inklusive Hormonlabor, dynamischer Pharmako-Duplexsonographie und, falls indiziert, mit einer Cavernosometrie/ -graphie. Zur Testung der penilen Rigidität und zur Objektivierung der Erektion wurde das "real-time" RigiScan® verwendet. In zwei konsekutiven Messungen wurden sowohl die direkte erektile Antwort auf visuelle Stimulation als auch die nächtlichen Erektionen abgeleitet und die Meßergebnisse mit den Begleiterkrankungen, "lifestyle"-Faktoren und dem Ergebnis der Pharmako-Duplexsonographie korreliert. Es fand sich keine Korrelation zwischen der Ätiologie der erektilen Dysfunktion in bezug auf organische oder psychogene Genese und dem Alter der Patienten, der Dauer der Erektionsstörung, dem Nikotinabusus, den Blutfetten, den Testosteronwerten, dem klinischen Ergebnis der Pharmakotestung (Erektionsgrad und dem duplexsonographisch gemessenen Fluß der penilen Arterien. Hingegen zeigte sich eine positive Korrelation zwischen Genese der erektilen Dysfunktion (organisch bzw. psychogen und dem RigiScan®-Meßergebnis (r = 0,29. Patienten mit psychogen bedingter Erektionsstörung profitierten am meisten von Viagra™, während Patienten mit vaskulärer Genese oder gemischt neurogener/vaskulärer Genese deutlich schlechter auf Viagra™ ansprachen. Es bestand keine Korrelation

  18. Performance evaluation of a computed radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Roussilhe, J.; Fallet, E. [Carestream Health France, 71 - Chalon/Saone (France); Mango, St.A. [Carestream Health, Inc. Rochester, New York (United States)

    2007-07-01

    Computed radiography (CR) standards have been formalized and published in Europe and in the US. The CR system classification is defined in those standards by - minimum normalized signal-to-noise ratio (SNRN), and - maximum basic spatial resolution (SRb). Both the signal-to-noise ratio (SNR) and the contrast sensitivity of a CR system depend on the dose (exposure time and conditions) at the detector. Because of their wide dynamic range, the same storage phosphor imaging plate can qualify for all six CR system classes. The exposure characteristics from 30 to 450 kV, the contrast sensitivity, and the spatial resolution of the KODAK INDUSTREX CR Digital System have been thoroughly evaluated. This paper will present some of the factors that determine the system's spatial resolution performance. (authors)

  19. Digital radiography exposure indices: A review

    Energy Technology Data Exchange (ETDEWEB)

    Mothiram, Ursula; Brennan, Patrick C; Lewis, Sarah J [Medical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, Faculty of Health Science, University of Sydney, Sydney, New South Wales (Australia); Moran, Bernadette [Department of Clinical Medicine, Trinity College, Dublin (Ireland); Robinson, John [Medical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, Faculty of Health Science, University of Sydney, Sydney, New South Wales (Australia)

    2014-06-15

    Digital radiography (DR) technologies have the advantage of a wide dynamic range compared to their film-screen predecessors, however, this poses a potential for increased patient exposure if left unchecked. Manufacturers have developed the exposure index (EI) to counter this, which provides radiographers with feedback on the exposure reaching the detector. As these EIs were manufacturer-specific, a wide variety of EIs existed. To offset this, the international standardised EI has been developed by the International Electrotechnical Commission (IEC) and the American Association of Physicists in Medicine (AAPM). The purpose of this article is to explore the current literature relating to EIs, beginning with the historical development of the EI, the development of the standardised EI and an exploration of common themes and studies as evidenced in the research literature. It is anticipated that this review will provide radiographers with a useful guide to understanding EIs, their application in clinical practice, limitations and suggestions for further research.

  20. Machine learning applied to proton radiography

    CERN Document Server

    Chen, Nicholas Fang Yew; Ceurvorst, Luke; Ratan, Naren; Sadler, James; Levy, Matthew; Trines, Raoul; Bingham, Robert; Norreys, Peter

    2016-01-01

    Proton radiography is a technique extensively used to resolve magnetic field structures in high energy density plasmas, revealing a whole variety of interesting phenomena such as magnetic reconnection and collisionless shocks found in astrophysical systems. Existing methods of analyzing proton radiographs give mostly qualitative results or specific quantitative parameters such as magnetic field strength, and recent work showed that the line-integrated transverse magnetic field can be reconstructed in specific regimes where many simplifying assumptions were needed. Using artificial neural networks, we suggest a novel 3-D reconstruction method that works for a more general case. A proof of concept is presented here, with mean reconstruction errors of less than 5 percent even after introducing noise. We demonstrate that over the long term, this approach is more computationally efficient compared to other techniques. We also highlight the need for proton tomography because (i) certain field structures cannot be r...

  1. Oral history in radiography: Listening to pioneers

    Energy Technology Data Exchange (ETDEWEB)

    Ferris, Christine [International Development Facilitator, Robert Winston Building, Faculty of Health and Wellbeing, Sheffield Hallam University, Sheffield S10 2BP (United Kingdom)], E-mail: c.m.ferris@shu.ac.uk; Winslow, Michelle [University of Sheffield, Oral History Society, Academic Unit of Supportive Care, Sykes House, Little Common Lane, Sheffield S11 9NE (United Kingdom)], E-mail: m.winslow@sheffield.ac.uk

    2009-12-15

    We explore the professional value of the collection and analysis of oral histories in the history of radiography. Drawing on oral histories collected from radiographers, we analyse accounts of experiences to identify common themes, some of which are of current significance, whilst others have faded from existence. 15 oral histories were collected from radiographers whose combined practice spans the years 1930-1973. The sample consists of 6 male and 9 female radiographers. Themes identified in the oral histories include radiographers as invisible pioneers who worked in professionally unclaimed territory and their dangerous working environment. The oral histories reveal the working world of the radiographer as having encompassed a practice ethos where challenges became an accepted part of work. We gain insight into less observable aspects of the radiographer's role, the difficulties they faced, how they invented techniques and equipment, and how they managed their practice including protecting the public from ionising radiation sources.

  2. Polarized neutron radiography with a periscope

    Science.gov (United States)

    Schulz, Michael; Neubauer, Andreas; Mühlbauer, Martin; Calzada, Elbio; Schillinger, Burkhard; Pfleiderer, Christian; Böni, Peter

    2010-01-01

    The interaction of the magnetic moment of the neutron with magnetic fields provides a powerful probe for spatially resolved magnetisation measurements in magnetic materials. We have tested a periscope as a new type of polarizer providing neutron beams with a high polarization and a low divergence. The observed inhomogeneity of the beam caused by the waviness of the glass substrates was quantified by means of Monte-Carlo simulations using the software package McStas. The results show that beams of high homogeneity can be produced if the waviness is reduced to below 1.0·10-5 rad. Finally, it is shown that radiography with polarized neutrons is a powerful method for measuring the spatially resolved magnetisation in optically float-zoned samples of the weak itinerant ferromagnet Ni3Al, thereby aiding the identification of the appropriate growth parameters.

  3. Polarized neutron radiography with a periscope

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Michael; Neubauer, Andreas; Muehlbauer, Martin; Schillinger, Burkhard; Pfleiderer, Christian; Boeni, Peter [Technische Universitaet Muenchen, Physik Department, E21, Garching (Germany); Calzada, Elbio, E-mail: michael.schulz@frm2.tum.d [Technische Universitaet Muenchen, Forschungsneutronenquelle Heinz Maier Leibnitz (FRM II), Garching (Germany)

    2010-01-01

    The interaction of the magnetic moment of the neutron with magnetic fields provides a powerful probe for spatially resolved magnetisation measurements in magnetic materials. We have tested a periscope as a new type of polarizer providing neutron beams with a high polarization and a low divergence. The observed inhomogeneity of the beam caused by the waviness of the glass substrates was quantified by means of Monte-Carlo simulations using the software package McStas. The results show that beams of high homogeneity can be produced if the waviness is reduced to below 1.0{center_dot}10{sup -5} rad. Finally, it is shown that radiography with polarized neutrons is a powerful method for measuring the spatially resolved magnetisation in optically float-zoned samples of the weak itinerant ferromagnet Ni{sub 3}Al, thereby aiding the identification of the appropriate growth parameters.

  4. Measuring microfocus focal spots using digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Fry, David A [Los Alamos National Laboratory

    2009-01-01

    Measurement of microfocus spot size can be important for several reasons: (1) Quality assurance during manufacture of microfocus tubes; (2) Tracking performance and stability of microfocus tubes; (3) Determining magnification (especially important for digital radiography where the native spatial resolution of the digital system is not adequate for the application); (4) Knowledge of unsharpness from the focal spot alone. The European Standard EN 12543-5 is based on a simple geometrical method of calculating focal spot size from unsharpness of high magnification film radiographs. When determining microfocus focal spot dimensions using unsharpness measurements both signal-to-noise (SNR) and magnification can be important. There is a maximum accuracy that is a function of SNR and therefore an optimal magnification. Greater than optimal magnification can be used but it will not increase accuracy.

  5. Vertex occlusal radiography in localizing unerupted mesiodentes

    Directory of Open Access Journals (Sweden)

    P Chalakkal

    2011-01-01

    Full Text Available The aim was to compare the vertex occlusal projection with the anterior maxillary occlusal projection in localizing the position of mesiodentes. Mesiodentes were observed in an 8-year-old boy with an anterior maxillary occlusal radiograph. A vertex occlusal radiograph was taken to compare it with the former in terms of mesiodentes localization with respect to the maxillary central incisors. The vertex occlusal radiograph provided greater details of the position and proximity of mesiodentes with respect to the long axis of maxillary central incisors in comparison to the anterior maxillary occlusal radiograph. Vertex occlusal radiography is an important diagnostic tool in diagnosing the presence, position, and proximity of mesiodentes with respect to the long axis of normally aligned maxillary central incisors. However, it is not recommended for routine use in a patient as its radiation dose is higher than conventional intraoral radiographic methods.

  6. Muscle parameters estimation based on biplanar radiography.

    Science.gov (United States)

    Dubois, G; Rouch, P; Bonneau, D; Gennisson, J L; Skalli, W

    2016-11-01

    The evaluation of muscle and joint forces in vivo is still a challenge. Musculo-Skeletal (musculo-skeletal) models are used to compute forces based on movement analysis. Most of them are built from a scaled-generic model based on cadaver measurements, which provides a low level of personalization, or from Magnetic Resonance Images, which provide a personalized model in lying position. This study proposed an original two steps method to access a subject-specific musculo-skeletal model in 30 min, which is based solely on biplanar X-Rays. First, the subject-specific 3D geometry of bones and skin envelopes were reconstructed from biplanar X-Rays radiography. Then, 2200 corresponding control points were identified between a reference model and the subject-specific X-Rays model. Finally, the shape of 21 lower limb muscles was estimated using a non-linear transformation between the control points in order to fit the muscle shape of the reference model to the X-Rays model. Twelfth musculo-skeletal models were reconstructed and compared to their reference. The muscle volume was not accurately estimated with a standard deviation (SD) ranging from 10 to 68%. However, this method provided an accurate estimation the muscle line of action with a SD of the length difference lower than 2% and a positioning error lower than 20 mm. The moment arm was also well estimated with SD lower than 15% for most muscle, which was significantly better than scaled-generic model for most muscle. This method open the way to a quick modeling method for gait analysis based on biplanar radiography.

  7. How to create a degree course in radiography: a recipe

    Energy Technology Data Exchange (ETDEWEB)

    Pratt, S. E-mail: Pratt@cf.ac.uk; Adams, C. E-mail: AdamsC1@cf.ac.uk

    2003-11-01

    This article explains how an undergraduate programme is devised and validated. Since 1993, all courses in radiography have been of graduate level with radiography education being based in higher educational institutions. Before a new degree is implemented a review of the existing programme is undertaken. The proposed degree philosophy and learning outcomes need to be determined before the content; its mode of delivery and assessment are developed. Input from stakeholders (such as clinical colleagues) is necessary as well as adherence to policies and strategies for radiography education. Throughout the development process compliance with policy, both national and local, is critical. All radiography programmes have to be validated/accredited by representatives from national organisations--such as The Society and College of Radiographers (SCoR). These representatives scrutinise the proposed degree course documentation; often they may also inspect the clinical and university facilities in which the education and training will take place.

  8. Comparison of ultrasonography and radiography in diagnosis of rib fractures.

    Science.gov (United States)

    Pishbin, Elham; Ahmadi, Koorosh; Foogardi, Molood; Salehi, Maryam; Seilanian Toosi, Farrokh; Rahimi-Movaghar, Vafa

    2017-08-01

    Rib fractures are the most common skeletal thoracic injuries resulting from blunt chest trauma. Half of the rib fractures are not detected upon a precise physical evaluation and radiographs. Recently ultrasonography (USG) has been investigated to detect rib fractures. But based on literature the usefulness of USG varies widely. This study was conducted to investigate the role of USG in the detection of possible rib fractures in comparison with radiography. In this cross-sectional study, consecutive patients with minor blunt chest trauma and suspected rib fractures presenting in Imam Reza Hospital located in Mashhad-Iran, between April 2013 and October 2013 were assessed by USG and radiography. The radiography was performed in a posteroanterior (PA) chest projection and oblique rib view centered over the area of trauma. The time duration spent in taking USG and radiography were recorded. The prevalence and location of fractures revealed by USG and radiography were compared. Sixty-one suspected patients were assessed. The male to female ratio was 2.4:1 (43 men and 18 women) with a mean ± SD age of (44.3 ± 19.7) years. There were totally 59 rib fractures in 38 (62.3%) patients based on radiography and USG, while 23 (37.7%) patients had no diagnostic evidence of rib lesions. USG revealed 58 rib fractures in 33 (54.1%) of 61 suspected patients and radiographs revealed 32 rib fractures in 20 (32.8%) of 61 patients. A total of 58 (98.3%) rib fractures were detected by USG, whereas oblique rib view and PA chest radiography showed 27 (45.8%) and 24 (40.7%) rib fractures, respectively. The average duration of USG was (12 ± 3) min (range 7-17 min), whereas the duration of radiography was (27 ± 6) min (range 15-37 min). The kappa coefficient showed a low level of agreement between both USG and PA chest radiography (kappa coefficient = 0.28), and between USG and oblique rib view (kappa coefficient = 0.32). USG discloses more fractures than radiography in

  9. Demenz und Depression bei Patienten mit idiopathischem Parkinson-Syndrom

    Directory of Open Access Journals (Sweden)

    Herting B

    2007-01-01

    Full Text Available Das idiopathische Parkinson-Syndrom (IPS ist eine progressive neurodegenerative Erkrankung mit motorischen und nicht-motorischen Symptomen. Bei Patienten mit IPS sind kognitive Defizite und Demenzen mit einer Prävalenz von 20–40 % nachgewiesen worden. Risikofaktoren für das Auftreten einer Parkinson-Demenz (PDe sind hohes Alter bei Krankheitsbeginn, schwere und/oder beidseitige motorische Symptomatik, Verwirrtheitszustände unter Levodopa-Medikation, aber auch Demenzerkrankungen in der Familie und niedriges Bildungsniveau. Patienten mit PDe weisen eine erhöhte Morbidität und Mortalität im Vergleich zu Patienten mit IPS ohne Demenz und der altersgleichen Normalbevölkerung auf, die unabhängig von der Schwere der motorischen Einbußen zweifach erhöht ist. Die Depression ist das häufigste psychiatrische Symptom beim IPS (die Angaben zur Prävalenz schwanken zwischen 4 % und 70 % und beeinflußt neben den Aktivitäten des täglichen Lebens wesentlich die Lebensqualität der Betroffenen. Darin liegt auch die Herausforderung, kognitive und affektive Symptome effizient zu behandeln.

  10. The micro turbine: the MIT example; La micro turbine: l'exemple du MIT

    Energy Technology Data Exchange (ETDEWEB)

    Ribaud, Y. [Office National d' Etudes et de Recherches Aerospatiales (ONERA-DEFA), 92 - Chatillon (France)

    2001-10-01

    The micro turbine study began a few years ago at the MIT, with the participation of specialists from different fields. The purpose is the development of a MEMS (micro electro mechanical systems) based, 1 cm in diameter, micro gas turbine. Potential applications are devoted to micro drone propulsion, electric power generation for portable power sources in order to replace heavy Lithium batteries, satellite motorization, the surface distributed power for boundary suction on plane wings. The manufacturing constraints at such small scales lead to 2-D extruded shapes. The physical constraints stem from viscous effects and from limitations given by 2-D geometry. The time scales are generally shorter than for conventional machines. Otherwise the material properties are better at such length scales. Transposition from conventional turbomachinery laws is no more applicable and new design methods must be established. The present paper highlights the project progress and the technology breakthroughs. (author)

  11. Islam, Migration und Integration: Konflikte jugendlicher Migranten mit islamischem Hintergrund

    Directory of Open Access Journals (Sweden)

    Ilhan Kizilhan

    2008-04-01

    Full Text Available Der Islam mit seinen verschiedenen Verhaltensweisen und Verboten spielt direkt oder indirekt immer noch eine wichtige Rolle im alltäglichen Leben vieler Migranten. Religiöse Vorschriften zeichnen sich dadurch aus, dass ihrer Achtung nicht juristisch, sondern durch sozialen Druck Nachdruck verliehen wird (Verwandtschaft, religiöse Lehrer, islamische Gemeinde, religiöse Vereine etc. und dass ihre Missachtung mit Folgen in Form von Ausgrenzung, Missachtung und Diskriminierung einhergeht. Die kulturellen Vorstellungen der ersten Generation unterscheiden sich auf Grund der unterschiedlichen Biografien von denen der zweiten und dritten durch den Grad der Verwurzelung in der kulturellen Identität und der Verbundenheit mit traditionellen Wertvorstellungen. Fehlende Integrationskonzepte, Ausgrenzung im Migrationsland auf der einen und weltweite staatliche und halbstaatliche Konflikte im Namen des Islams bis hin zum Terrorismus auf der anderen Seite haben einen erheblichen Einfluss auf den Integrationsgrad von jugendlichen Migranten im Aufnahmeland.

  12. Professionell entwickeln mit Java EE 7 das umfassende Handbuch

    CERN Document Server

    Salvanos, Alexander

    2014-01-01

    Ein praxisorientiertes Lehrbuch zur JEE 7 und zugleich ein Standardwerk, das Sie auf Ihrem Weg zum Enterprise-Entwickler begleitet. Inklusive Best Practices für leichtgewichtige Enterprise Applications, Standards zu servicebasierten Anwendungen, Persistence API, Dependency Injection, HTML5 und Performance-Tuning. Aus dem Inhalt: Grundlagen und Installation Software-Architektur mit Java EE Webanwendungen mit HTML5 und CSS3 Java Standard Tag Library Asynchrone Servlets und Non-blocking I/O Datenbanken anbinden mit der JDBC API Java Server Faces Datenbank-Organisation Java Persistence API Objektrelationales Mapping Transaktionssicherheit Performance-Tuning Internationalisierung Enterprise Java Beans WebSockets PrimeFaces Deployment Galileo Press heißt von jetzt an Rheinwerk Verlag.

  13. Beam Characterization at the Neutron Radiography Facility

    Energy Technology Data Exchange (ETDEWEB)

    Sarah Morgan; Jeffrey King

    2013-01-01

    The quality of a neutron imaging beam directly impacts the quality of radiographic images produced using that beam. Fully characterizing a neutron beam, including determination of the beam’s effective length-to-diameter ratio, neutron flux profile, energy spectrum, image quality, and beam divergence, is vital for producing quality radiographic images. This project characterized the east neutron imaging beamline at the Idaho National Laboratory Neutron Radiography Reactor (NRAD). The experiments which measured the beam’s effective length-to-diameter ratio and image quality are based on American Society for Testing and Materials (ASTM) standards. An analysis of the image produced by a calibrated phantom measured the beam divergence. The energy spectrum measurements consist of a series of foil irradiations using a selection of activation foils, compared to the results produced by a Monte Carlo n-Particle (MCNP) model of the beamline. Improvement of the existing NRAD MCNP beamline model includes validation of the model’s energy spectrum and the development of enhanced image simulation methods. The image simulation methods predict the radiographic image of an object based on the foil reaction rate data obtained by placing a model of the object in front of the image plane in an MCNP beamline model.

  14. Alpha particle radiography of small insects

    Energy Technology Data Exchange (ETDEWEB)

    Chingshen Su [National Tsing Hua Univ., Hsinchu (Taiwan) Inst. of Nuclear Science

    1993-12-31

    Radiographies of ants, mosquitoes, cockroaches and small bugs have been done with a radioisotope {sup 244}Cm alpha source. Energy of alpha particles was varied by attenuating the 5.81 MeV alpha particles with adjustable air spacings from the source to the sample. The LR-115 was used to register radiographs. The image of the insect registered on the LR-115 was etched out in a 2.5 N NaOH solution at 52{sup o}C for certain minutes, depending on various irradiation conditions for the insects. For larger insects, a scanning device for the alpha particle irradiation has been fabricated to take the radiograph of whole body of the insect, and the scanning period can be selected to give desired irradiation dosage. A CCDTV camera system connected to a microscope interfaced to an IBM/AT computer is used to register the microscopic image of the radiograph and to print it out with a video copy processor. (Author).

  15. Comparison of state dental radiography safety regulations.

    Science.gov (United States)

    McDaniel, Thomas F; Parashar, Vijay

    2015-01-01

    The aim of this study was to compare and provide an overview of state policies on occupational exposure, dosimetry, collimation, patient protection, and the use of portable handheld X-ray machines in dentistry. State government webpages containing radiation protection rules and regulations were scanned. The contents were compared against current federal regulations established by the Nuclear Regulatory Commission (NRC) and the US Food and Drug Administration (FDA). They were further evaluated in light of current recommendations from the National Council on Radiation Protection & Measurements (NCRP) and the American Dental Association (ADA). Most states' regulations mirror the exposure limits set forth by the NRC and FDA. Nonregulatory recommendations regarding use of dental radiography are periodically put forth by the NCRP and the ADA. State and federal agencies often follow recommendations from these scientific organizations when creating regulations. Clinicians must be aware of their state's radiation protection rules, as variations among states exist. In addition, recommendations published by organizations such as the NCRP and the ADA, while not legally binding, contribute significantly to the reduction of radiation risks for operators and patients alike.

  16. A dose monitoring system for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chena; Lee, Sam Sun; Kim, Jo Eun; Huh, Kyung Hoe; Yi, Woo Jin; Heo, Min Suk; Choi, Soon Chul [Dept. of Oral and Maxillofacial Radiology and Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of); Symkhampha, Khanthaly [Dept. of Oral and Maxillofacial Radiology, Department of Basic Science, Faculty of Dentistry, University of Health Sciences, Vientiane (Lao People' s Democratic Republic); Lee, Woo Jin [Dept. of Interdisciplinary Program in Radiation, Applied Life Sciences Major, College of Medicine, BK21, and Dental Research Institute, Seoul National University, Seoul (Korea, Republic of); Yeom, Heon Young [School of Computer Science Engineering, Seoul National University, Seoul (Korea, Republic of)

    2016-06-15

    The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

  17. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  18. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  19. Towards Proton Therapy and Radiography at FAIR

    Science.gov (United States)

    Prall, M.; Lang, P. M.; LaTessa, C.; Mariam, F.; Merrill, F.; Shestov, L.; Simoniello, P.; Varentsov, D.; Durante, M.

    2015-04-01

    Protons having energies in the GeV range have been proposed as an alternative to Bragg-peak hadron therapy. This strategy reduces lateral scattering and overcomes uncertainties of particle range and relative biological effectiveness. GeV protons could additionally be used for targeting in image guided stereotactic radiosurgery. We experimentally demonstrated the potential of GeV protons for imaging of biological samples using E=0.8 GeV protons and the pRad setup at Los Alamos National Laboratory (LANL). In this setup, a system of magnetic lenses creates a point-to-point mapping from object to detector. This mapping compensates image blur due to lateral scattering inside the imaged (biological) object. We produced 2-dim proton radiographs of biological samples, an anthropomorphic phantom and performed simple dosimetry. High resolution tomographic reconstructions were derived from the 2-dim proton radiographs. Our experiment was performed within the framework of the PANTERA (Proton Therapy and Radiography) project. In the future, the proton microscope PRIOR (Proton Microscope for FAIR) located in the FAIR facility (Darmstadt), will focus on optimizing the technique for imaging of lesions implanted in animals and couple the irradiation with standard radiotherapy.

  20. „Schloss mit der Debatte!“?

    OpenAIRE

    Birkholz, Tim

    2008-01-01

    Am 19. Januar 2006 beschloss der Deutsche Bundestag mit überwältigender Mehrheit den Abriss des Palastes der Republik. Kurz darauf wurde auf dem Schlossplatz im historischen Zentrum von Berlin mit dem Abtragen des in der Ära Honecker errichteten Gebäudes begonnen. In ähnlicher Deutlichkeit war bereits die Rekonstruktion des Berliner Schlosses beschlossen worden, welches zuvor an gleicher Stelle stehend von der DDR-Regierung unter Walter Ulbricht abgerissen worden war. Die Mehrheitsverhältniss...

  1. Fallstudie SIG - Supply Chain Prototyp mit Coca Cola Beverages

    OpenAIRE

    Senger, Enrico

    2003-01-01

    SIG, ein führender Lieferant von Verpackungsmaterialien für Getränke, hat mit Coca Cola CPFR, collaborative planning, forecasting and replenishment realisiert. Das Unternehmen kann elektronisch und ohne Zeitverzug (vorher mit bis zu 15 Tagen Verspätung) auf die Lagerbestände und Verkaufsvorhersagen bei Coca Cola zugreifen. Coca Cola erhält die exakten Liefermengen und zeiten. Coca Cola konnte dadurch den Lagerbestand von Verpackungsmaterial um 50% senken. Dies reduziert die Bearbeitungszeit d...

  2. Fallstudie SIG - Supply Chain Prototyp mit Coca Cola Beverages

    OpenAIRE

    Senger, Enrico

    2003-01-01

    SIG, ein führender Lieferant von Verpackungsmaterialien für Getränke, hat mit Coca Cola CPFR, collaborative planning, forecasting and replenishment realisiert. Das Unternehmen kann elektronisch und ohne Zeitverzug (vorher mit bis zu 15 Tagen Verspätung) auf die Lagerbestände und Verkaufsvorhersagen bei Coca Cola zugreifen. Coca Cola erhält die exakten Liefermengen und zeiten. Coca Cola konnte dadurch den Lagerbestand von Verpackungsmaterial um 50% senken. Dies reduziert die Bearbeitungszeit d...

  3. Clinical application of computed radiography; Comparison of computed radiography and conventional radiography in the detection of microcalcifications and pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Higashida, Yoshiharu (Kumamoto Univ. (Japan). Coll. of Medical Science)

    1990-10-01

    Observer performance tests were performed to compare the diagnostic accuracy of digitized storage phosphors and conventional radiography in the detection of microcalcification in the breast and pulmonary nodules. Clustered microcalcifications were randomly superimposed on a human breast specimen. Two types of screen-film systems (Toshiba MM6/Fuji MINC, Kodak MinR/Kodak MinR) and CR images either with unsharp mask or with no image processing (unprocess) were used as imaging systems. Nine readers assessed the capability of screen-films, and unsharp-masked and unprocessed mammograms to detect microcalcifications. Observer performance data were evaluated by receiver operating characteristics (ROC) analysis. Both the area under ROC curve and the true positive localization fraction were used as performance indexes. Two screen-film images provided a higher detectability of microcalcifications than CR images. In the detectability of microcalcifications, unsharp-masked images were superior to unprocessed images. CR images showed higher false positive fraction than screen-film systems. To assess the detectability of pulmonary nodules, 15 radiologists compared the diagnostic accuracy of screen-film system and CR images, including unprocessed, unsharp-masked, reversed and paired images, in 18 normal volunteers and 18 patients with pulmonary nodules. Overall diagnostic accuracy of CR images, except for reversed images, were comparable to the screen-film system. In case of definite, large nodules, unprocessed, unsharp-masked, and paired images were superior to the screen-film and reversed images. Screen-film and unprocessed images were helpful in cases of tiny nodules without definite contrast. 59 refs.

  4. Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography

    Directory of Open Access Journals (Sweden)

    Wilton Mitsunari Takeshita

    2013-01-01

    Full Text Available Background: To compare the diagnostic accuracy of three different imaging systems: Direct digital radiography system (DDR-CMOS, four types of filtered images, and a priori and a posteriori registration of digital subtraction radiography (DSR in the diagnosis of proximal defects. Materials and Methods: The teeth were arranged in pairs in 10 blocks of vinyl polysiloxane, and proximal defects were performed with drills of 0.25, 0.5, and 1 mm diameter. Kodak RVG 6100 sensor was used to capture the images. A posteriori DSR registrations were done with Regeemy 0.2.43 and subtraction with Image Tool 3.0. Filtered images were obtained with Kodak Dental Imaging 6.1 software. Images (n = 360 were evaluated by three raters, all experts in dental radiology. Results: Sensitivity and specificity of the area under the receiver operator characteristic (ROC curve (Az were higher for DSR images with all three drills (Az = 0.896, 0.979, and 1.000 for drills 0.25, 0.5, and 1 mm, respectively. The highest values were found for 1-mm drills and the lowest for 0.25-mm drills, with negative filter having the lowest values of all (Az = 0.631. Conclusion: The best method of diagnosis was by using a DSR. The negative filter obtained the worst results. Larger drills showed the highest sensitivity and specificity values of the area under the ROC curve.

  5. A method to optimize the processing algorithm of a computed radiography system for chest radiography.

    Science.gov (United States)

    Moore, C S; Liney, G P; Beavis, A W; Saunderson, J R

    2007-09-01

    A test methodology using an anthropomorphic-equivalent chest phantom is described for the optimization of the Agfa computed radiography "MUSICA" processing algorithm for chest radiography. The contrast-to-noise ratio (CNR) in the lung, heart and diaphragm regions of the phantom, and the "system modulation transfer function" (sMTF) in the lung region, were measured using test tools embedded in the phantom. Using these parameters the MUSICA processing algorithm was optimized with respect to low-contrast detectability and spatial resolution. Two optimum "MUSICA parameter sets" were derived respectively for maximizing the CNR and sMTF in each region of the phantom. Further work is required to find the relative importance of low-contrast detectability and spatial resolution in chest images, from which the definitive optimum MUSICA parameter set can then be derived. Prior to this further work, a compromised optimum MUSICA parameter set was applied to a range of clinical images. A group of experienced image evaluators scored these images alongside images produced from the same radiographs using the MUSICA parameter set in clinical use at the time. The compromised optimum MUSICA parameter set was shown to produce measurably better images.

  6. Combined effects of ozone and other air pollutants, especially allergens; Kombinationswirkung von Ozon mit anderen Luftschadstoffen, insbesondere mit Allergenen

    Energy Technology Data Exchange (ETDEWEB)

    Nowak, D. [Muenchen Univ. (Germany). Inst. fuer Arbeits- und Umweltmedizin; Joerres, R.; Magnussen, H. [Krankenhaus Grosshansdorf (Germany). Zentrum fuer Pneumologie und Thoraxchirurgie

    2000-07-01

    Ozone effects in humans may either be examined in epidemiological or in clinical exposure studies. In the natural environment ozone does not occur alone but only in combination with other noxious agents. The present summary gives an overview of the literature on combined effects of ozone and allergens. [German] Ozoneffekte auf den Menschen koennen zum einen in epidemiologischen, zum anderen in klinischen Expositionsstudien untersucht werden. In der natuerlichen Umwelt des Menschen tritt Ozon nicht allein auf, sondern mit anderen Noxen kombiniert. Die vorliegende Zusammenfassung ist eine Literaturuebersicht ueber die Kombinationswirkung von Ozon mit Allergenen. (orig.)

  7. A benchmark for comparison of dental radiography analysis algorithms.

    Science.gov (United States)

    Wang, Ching-Wei; Huang, Cheng-Ta; Lee, Jia-Hong; Li, Chung-Hsing; Chang, Sheng-Wei; Siao, Ming-Jhih; Lai, Tat-Ming; Ibragimov, Bulat; Vrtovec, Tomaž; Ronneberger, Olaf; Fischer, Philipp; Cootes, Tim F; Lindner, Claudia

    2016-07-01

    Dental radiography plays an important role in clinical diagnosis, treatment and surgery. In recent years, efforts have been made on developing computerized dental X-ray image analysis systems for clinical usages. A novel framework for objective evaluation of automatic dental radiography analysis algorithms has been established under the auspices of the IEEE International Symposium on Biomedical Imaging 2015 Bitewing Radiography Caries Detection Challenge and Cephalometric X-ray Image Analysis Challenge. In this article, we present the datasets, methods and results of the challenge and lay down the principles for future uses of this benchmark. The main contributions of the challenge include the creation of the dental anatomy data repository of bitewing radiographs, the creation of the anatomical abnormality classification data repository of cephalometric radiographs, and the definition of objective quantitative evaluation for comparison and ranking of the algorithms. With this benchmark, seven automatic methods for analysing cephalometric X-ray image and two automatic methods for detecting bitewing radiography caries have been compared, and detailed quantitative evaluation results are presented in this paper. Based on the quantitative evaluation results, we believe automatic dental radiography analysis is still a challenging and unsolved problem. The datasets and the evaluation software will be made available to the research community, further encouraging future developments in this field. (http://www-o.ntust.edu.tw/~cweiwang/ISBI2015/).

  8. Dual-energy subtraction radiography of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-06-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses.

  9. Application of digital radiography in the analysis of cultural heritage

    Energy Technology Data Exchange (ETDEWEB)

    Oiveira, Davi F.; Calza, Cristiane; Rocha, Henrique S.; Nascimento, Joseilson R.; Lopes, Ricardo T., E-mail: davi@lin.ufrj.br, E-mail: ccalza@lin.ufrj.br, E-mail: henrique@lin.ufrj.br, E-mail: joseilson@lin.ufrj.br, E-mail: ricardo@lin.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentacao Nuclear

    2013-07-01

    The scientific examination of artworks has gained increasing interest in the last years, allowing the characterization of materials and techniques employed by the artists. This analysis can be extremely valuable to conservation and restoration treatments. However, the fact that every artworks is a unique piece emphasizes the necessity of working with non-destructive techniques. Although radiography has been used in the technical examination of museum objects for many decades, digital radiography is rapidly becoming a preferred modality for this essential tool in the advanced examination of works of art. The ability to electronically combine images from the large painting into a single composite image file was extremely valuable and results in higher quality images than those achieved with conventional radiography. These images can be also processed and improved using adequate software. Additional advantages of digital radiography include the possibility of an almost immediate analysis of the results, use of an only recording film and absence of chemical processing. Radiographic imaging can be applied to the analysis of virtually all media including paintings, sculptures, woodworks, engravings, etc. This paper reports some case studies of the use of digital radiography in the study of paintings and sculptures, showing the feasibility and advantages of this technique for this kind of purpose. The radiographic images revealed the conservation state of the analyzed objects and various details of its execution in order to assist recently restoration processes. (author)

  10. Wie ich mich mit dem äthiopischen Regime anlegte

    DEFF Research Database (Denmark)

    Hagmann, Tobias

    2016-01-01

    Als Forscher und Kritiker der äthiopischen Politik habe ich viel über das Verhältnis gelernt, in dem Wahrheit und Macht, aber auch Moral und persönliche Interessen zueinander stehen. In den Niederungen der Realpolitik wird mit harten Bandagen um die Deutungshoheit gekämpft wird. Auch Wissenschafter...

  11. MIT Laboratory for Computer Science Progress Report 27

    Science.gov (United States)

    1990-06-01

    C. Waldspurger B. Gates M. Williams Undergraduate Students M. Levine A. Rhee V. Nicotina M. Sexton C. Poelman R. Stata Support Staff A. Rubin 113...Science, May 1990. [5] V. Nicotina . Implementing Mobile Guardians in Argus. Bachelor’s thesis, MIT Department of Electrical Engineering and Computer Science

  12. Numerische Berechnung von Wirbelstromproblemen mit der Cell-Methode

    Directory of Open Access Journals (Sweden)

    K. Frenner

    2006-01-01

    Full Text Available In dieser Arbeit wird die Cell-Methode auf die quasistatischen Maxwellgleichungen angewendet. Dabei werden für die notwendige Transformation vom Primärgitter auf das duale Gitter reziproke Basisvektoren verwendet. Anhand der Felddiffusion der magnetischen Induktion in einen zylindrischen Leiter werden Ergebnisse der Cell-Methode mit einer analytischen Vergleichsrechnung präsentiert.

  13. MIT Mints a Valuable New Form of Academic Currency

    Science.gov (United States)

    Carey, Kevin

    2012-01-01

    The Massachusetts Institute of Technology (MIT) has invented or improved many world-changing things--radar, information theory, and synthetic self-replicating molecules, to name a few. Last month the university announced, to mild fanfare, an invention that could be similarly transformative, this time for higher education itself. It is called MITx.…

  14. Interaktion mit RFID Ausleih- und Rückgabeautomaten

    DEFF Research Database (Denmark)

    Greifeneder, Elke; Heyroth, Melanie; Klingbeil, Karin

    2011-01-01

    Der Artikel untersucht mittels Beobachtung die Interaktion zwischen RFID-Ausleih- und Rückgabeautomaten sowie Bibliotheksbenutzern in vier deutschen Bibliotheken. Die Ergebnisse belegen, dass die Interaktion grundsätzlich funktioniert. Die Benutzer zeigten Gelassenheit und Routine im Umgang mit den...

  15. MIT Orients Course Materials Online to K-12

    Science.gov (United States)

    Cavanagh, Sean

    2008-01-01

    Many science and mathematics educators across the country are taking advantage of a Web site created by the Massachusetts Institute of Technology (MIT), the famed research university located in Cambridge, Massachusetts, which offers free video, audio, and print lectures and course material taken straight from the school's classes. Those resources…

  16. MIT Mints a Valuable New Form of Academic Currency

    Science.gov (United States)

    Carey, Kevin

    2012-01-01

    The Massachusetts Institute of Technology (MIT) has invented or improved many world-changing things--radar, information theory, and synthetic self-replicating molecules, to name a few. Last month the university announced, to mild fanfare, an invention that could be similarly transformative, this time for higher education itself. It is called MITx.…

  17. The Creation of OpenCourseWare at MIT

    Science.gov (United States)

    Abelson, Hal

    2008-01-01

    This paper traces the genesis of the MIT OpenCourseWare project from its initial strategic precursors in 1999 and 2000, through its launch in 2001 and its subsequent evolution. The story told here illuminates the interplay among institutional leadership, and strategic planning, and with university culture in launching major educational technology…

  18. MIT CSAIL and Lincoln Laboratory Task Force Report

    Science.gov (United States)

    2016-08-01

    operational capabilities. DARPA has used Challenge Events (2004/2005 Grand Challenge, 2007 Urban Challenge, 2012–15 DRC) to focus and accelerate...Atmospheric and Planetary Sciences EECS Electrical Engineering and Computer Science, MIT FHC Fully Homomorphic Computing FPGA Field-Programmable Gate Array

  19. Interaktion mit RFID Ausleih- und Rückgabeautomaten

    DEFF Research Database (Denmark)

    Greifeneder, Elke; Heyroth, Melanie; Klingbeil, Karin

    2011-01-01

    Der Artikel untersucht mittels Beobachtung die Interaktion zwischen RFID-Ausleih- und Rückgabeautomaten sowie Bibliotheksbenutzern in vier deutschen Bibliotheken. Die Ergebnisse belegen, dass die Interaktion grundsätzlich funktioniert. Die Benutzer zeigten Gelassenheit und Routine im Umgang mit den...

  20. Die Last mit der Lust The burden of lust

    Directory of Open Access Journals (Sweden)

    Lutz Sauerteig

    2004-03-01

    Full Text Available Robert Jütte legt mit Lust ohne Last eine umfassende, allgemeinverständliche und spannend zu lesende Geschichte der Empfängnisverhütung von der Antike bis in die unmittelbare Gegenwart vor.In Lust without Burden, Robert Jütte has written a comprehensive, accessible and gripping history of contraception from antiquity to the present.

  1. Parallelization experience with four canonical econometric models using ParMitISEM

    NARCIS (Netherlands)

    Baştürk, N.; Grassi, S.; Hoogerheide, L.; van Dijk, H.K.

    2016-01-01

    This paper presents the parallel computing implementation of the MitISEM algorithm, labeled Parallel MitISEM. The basic MitISEM algorithm, introduced by Hoogerheide et al. (2012), provides an automatic and flexible method to approximate a non-elliptical target density using adaptive mixtures of

  2. Parallelization experience with four canonical econometric models using ParMitISEM

    NARCIS (Netherlands)

    Bastürk, Nalan; Grassi, S.; Hoogerheide, L.; van Dijk, Herman K.

    2016-01-01

    This paper presents the parallel computing implementation of the MitISEM algorithm, labeled Parallel MitISEM. The basic MitISEM algorithm provides an automatic and flexible method to approximate a non-elliptical target density using adaptive mixtures of Student-t densities, where only a kernel of

  3. Parallelization Experience with Four Canonical Econometric Models Using ParMitISEM

    NARCIS (Netherlands)

    N. Basturk (Nalan); S. Grassi (Stefano); L.F. Hoogerheide (Lennart); H.K. van Dijk (Herman)

    2016-01-01

    textabstractThis paper presents the parallel computing implementation of the MitISEM algorithm, labeled Parallel MitISEM. The basic MitISEM algorithm, introduced by Hoogerheide, Opschoor and Van Dijk (2012), provides an automatic and flexible method to approximate a non-elliptical target density

  4. Parallelization experience with four canonical econometric models using ParMitISEM

    NARCIS (Netherlands)

    Baştürk, N.; Grassi, S.; Hoogerheide, L.; van Dijk, H.K.

    2016-01-01

    This paper presents the parallel computing implementation of the MitISEM algorithm, labeled Parallel MitISEM. The basic MitISEM algorithm, introduced by Hoogerheide et al. (2012), provides an automatic and flexible method to approximate a non-elliptical target density using adaptive mixtures of Stud

  5. Lung cancer screening with thoracic X-ray and CT. Current situation; Lungenkarzinomscreening mit Roentgenthorax oder CT. Aktuelle Datenlage

    Energy Technology Data Exchange (ETDEWEB)

    Stackelberg, O. von; Kauczor, H.U. [Universitaetsklinikum Heidelberg, Diagnostische und Interventionelle Radiologe, Heidelberg (Germany); Translationales Lungen Forschungszentrum Heidelberg (TLRC), Mitglied des Deutschen Zentrums fuer Lungenforschung (DZL), Heidelberg (Germany)

    2016-09-15

    Attempts at the early detection of lung cancer using imaging methods began as far back as the 1950s. Several studies attempted to demonstrate a reduction of lung cancer mortality by chest radiography screening but all were unsuccessful. Even the first small screening studies using computed tomography (CT) could not demonstrate a reduction in lung cancer-specific mortality until in 2011 the results of the largest randomized controlled low-dose CT screening study in the USA (NLST) were published. The NLST results could show a significant 20 % reduction of lung cancer mortality in elderly and heavy smokers using CT. Confirmation of the NLST results are urgently needed so that the data of the largest European study (NELSON) are eagerly awaited. Pooled with the data from several smaller European studies these results will provide important information and evidence for the establishment of future CT screening programs in Europe. Randomized controlled trials are the basis of evidence-based medicine; therefore, the positive results of the methodologically very good NLST study cannot be ignored, even if it is the only such study completed so far with highly convincing conclusions. The NLST results clearly demonstrate that positive effects for the health of the population can only be expected if the processes are clearly defined and the quality is assured. (orig.) [German] Bestrebungen zur Frueherkennung von Lungenkrebs mit bildgebenden Methoden gibt es schon lange. Alle Studien, die eine Reduktion der Lungenkrebsmortalitaet mittels Roentgenthoraxscreening nachzuweisen versuchten, scheiterten. Auch die ersten kleineren Screeningstudien mit der CT konnten keine Reduktion der Lungenkrebssterblichkeit nachweisen, bis 2011 die Ergebnisse der bisher groessten randomisierten kontrollierten Niedrigdosis-CT-Screeningstudie (NLST) aus den USA veroeffentlicht wurden. Diese konnten eine signifikante 20 %ige Reduktion der Lungenkrebssterblichkeit bei Personen, die aelter und starke

  6. Study of pipe thickness loss using a neutron radiography method

    Energy Technology Data Exchange (ETDEWEB)

    Mohamed, Abdul Aziz; Wahab, Aliff Amiru Bin [Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, 43000 Kajang, Selangor (Malaysia); Yazid, Hafizal B.; Ahmad, Megat Harun Al Rashid B. Megat; Jamro, Rafhayudi B.; Azman, Azraf B.; Zin, Muhamad Rawi Md; Idris, Faridah Mohamad [Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor (Malaysia)

    2014-02-12

    The purpose of this preliminary work is to study for thickness changes in objects using neutron radiography. In doing the project, the technique for the radiography was studied. The experiment was done at NUR-2 facility at TRIGA research reactor in Malaysian Nuclear Agency, Malaysia. Test samples of varying materials were used in this project. The samples were radiographed using direct technique. Radiographic images were recorded using Nitrocellulose film. The films obtained were digitized to processed and analyzed. Digital processing is done on the images using software Isee!. The images were processed to produce better image for analysis. The thickness changes in the image were measured to be compared with real thickness of the objects. From the data collected, percentages difference between measured and real thickness are below than 2%. This is considerably very low variation from original values. Therefore, verifying the neutron radiography technique used in this project.

  7. NEUTRON RADIOGRAPHY (NRAD) REACTOR 64-ELEMENT CORE UPGRADE

    Energy Technology Data Exchange (ETDEWEB)

    John D. Bess

    2014-03-01

    The neutron radiography (NRAD) reactor is a 250 kW TRIGA (registered) (Training, Research, Isotopes, General Atomics) Mark II , tank-type research reactor currently located in the basement, below the main hot cell, of the Hot Fuel Examination Facility (HFEF) at the Idaho National Laboratory (INL). It is equipped with two beam tubes with separate radiography stations for the performance of neutron radiography irradiation on small test components. The interim critical configuration developed during the core upgrade, which contains only 62 fuel elements, has been evaluated as an acceptable benchmark experiment. The final 64-fuel-element operational core configuration of the NRAD LEU TRIGA reactor has also been evaluated as an acceptable benchmark experiment. Calculated eigenvalues differ significantly (approximately +/-1%) from the benchmark eigenvalue and have demonstrated sensitivity to the thermal scattering treatment of hydrogen in the U-Er-Zr-H fuel.

  8. Wind Turbine Blade Nondestructive Testing with a Transportable Radiography System

    Directory of Open Access Journals (Sweden)

    J. G. Fantidis

    2011-01-01

    Full Text Available Wind turbines are becoming widely used as they are an environmentally friendly way for energy production without emissions; however, they are exposed to a corrosive environment. In addition, as wind turbines typically are the tallest structures in the surrounding area of a wind farm, it is expected that they will attract direct lightning strikes several times during their operating life. The purpose of this paper is to show that the radiography with a transportable unit is a solution to find defects in the wind turbine blade and reduce the cost of inspection. A transportable neutron radiography system, incorporating an Sb–Be source, has been simulated using the MCNPX code. The simulated system has a wide range of radiography parameters.

  9. Experimental Study on Neutron Radiography Device Based on Reactor

    Institute of Scientific and Technical Information of China (English)

    LU; Jin; PENG; Dan; HAO; Qian; YU; Bo-xiang; LI; Yi-guo

    2012-01-01

    <正>Neutron radiography is a non-destructive testing developing fast recently, which requires stable and proper neutron source with low γ background. Neutrons from In-hospital Neutron Irradiator (IHNI) could meet this requirement. Based on the neutron beams of IHNI, a collimator is designed and built for neutron radiography. The experiment results show that in the case of IHNI working at normal rated power, the neutron flux at the end of the collimator is 1.43×106 cm-2·s-1; The max collimation ratio (L/D) is 58; the γ dose rate is 6.3×106 mSv/s. In a word, the collimator could be used for neutron radiography.

  10. Proton Radiography as an electromagnetic field and density perturbation diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Mackinnon, A; Patel, P; Town, R; Edwards, M; Phillips, T; Lerner, S; Price, D; Hicks, D; Key, M; Hatchett, S; Wilks, S; King, J; Snavely, R; Freeman, R; Boehlly, T; Koenig, M; Martinolli, E; Lepape, S; Benuzzi-Mounaix, A; Audebert, P; Gauthier, J; Borghesi, M; Romagnani, L; Toncian, T; Pretzler, G; Willi, O

    2004-04-15

    Laser driven proton beams have been used to diagnose transient fields and density perturbations in laser produced plasmas. Grid deflectometry techniques have been applied to proton radiography to obtain precise measurements of proton beam angles caused by electromagnetic fields in laser produced plasmas. Application of proton radiography to laser driven implosions has demonstrated that density conditions in compressed media can be diagnosed with MeV protons. This data has shown that proton radiography can provide unique insight into transient electromagnetic fields in super critical density plasmas and provide a density perturbation diagnostics in compressed matter . PACS numbers: 52.50.Jm, 52.40.Nk, 52.40.Mj, 52.70.Kz

  11. Magnifying lens for 800 MeV proton radiography.

    Science.gov (United States)

    Merrill, F E; Campos, E; Espinoza, C; Hogan, G; Hollander, B; Lopez, J; Mariam, F G; Morley, D; Morris, C L; Murray, M; Saunders, A; Schwartz, C; Thompson, T N

    2011-10-01

    This article describes the design and performance of a magnifying magnetic-lens system designed, built, and commissioned at the Los Alamos National Laboratory (LANL) for 800 MeV flash proton radiography. The technique of flash proton radiography has been developed at LANL to study material properties under dynamic loading conditions through the analysis of time sequences of proton radiographs. The requirements of this growing experimental program have resulted in the need for improvements in spatial radiographic resolution. To meet these needs, a new magnetic lens system, consisting of four permanent magnet quadrupoles, has been developed. This new lens system was designed to reduce the second order chromatic aberrations, the dominant source of image blur in 800 MeV proton radiography, as well as magnifying the image to reduce the blur contribution from the detector and camera systems. The recently commissioned lens system performed as designed, providing nearly a factor of three improvement in radiographic resolution.

  12. Studies of solid propellant combustion with pulsed radiography

    Science.gov (United States)

    Godai, T.; Tanemura, T.; Fujiwara, T.; Shimizu, M.

    1987-01-01

    Pulsed radiography was applied to observe solid propellant surface regression during rocket motor operation. Using a 150 KV flash X-ray system manufactured by the Field Emission Corporation and two kinds of film suppliers, images of the propellant surface of a 5 cm diameter end burning rocket motor were recorded on film. The repetition frame rate of 8 pulses per second and the pulse train length of 10 pulses are limited by the capability of the power supply and the heat build up within the X-ray tube, respectively. The experiment demonstrated the effectiveness of pulsed radiography for observing solid propellant surface regression. Measuring the position of burning surface images on film with a microdensitometer, quasi-instantaneous burning rate as a function of pressure and the variation of characteristic velocity with pressure and gas stay time were obtained. Other research items to which pulsed radiography can be applied are also suggested.

  13. Application of Neutron Radiography to Flow Visualization in Supercritical Water

    Science.gov (United States)

    Takenaka, N.; Sugimoto, K.; Takami, S.; Sugioka, K.; Tsukada, T.; Adschiri, T.; Saito, Y.

    Supercritical water is used in various chemical reaction processes including hydrothermal synthesis of metal oxide nano-particles, oxidation, chemical conversion of biomass and plastics. Density of the super critical water is much less than that of the sub-critical water. By using neutron radiography, Peterson et al. have studied salt precipitation processes in supercritical water and the flow pattern in a reverse-flow vessel for salt precipitation, and Balasko et al. have revealed the behaviour of supercritical water in a container. The nano-particles were made by mixing the super critical flow and the sub critical water solution. In the present study, neutron radiography was applied to the flow visualization of the super and sub critical water mixture in a T-junction made of stainless steel pipes for high pressure and temperature conditions to investigate their mixing process. Still images by a CCD camera were obtained by using the neutron radiography system at B4 port in KUR.

  14. Deterministic simulation of thermal neutron radiography and tomography

    Science.gov (United States)

    Pal Chowdhury, Rajarshi; Liu, Xin

    2016-05-01

    In recent years, thermal neutron radiography and tomography have gained much attention as one of the nondestructive testing methods. However, the application of thermal neutron radiography and tomography is hindered by their technical complexity, radiation shielding, and time-consuming data collection processes. Monte Carlo simulations have been developed in the past to improve the neutron imaging facility's ability. In this paper, a new deterministic simulation approach has been proposed and demonstrated to simulate neutron radiographs numerically using a ray tracing algorithm. This approach has made the simulation of neutron radiographs much faster than by previously used stochastic methods (i.e., Monte Carlo methods). The major problem with neutron radiography and tomography simulation is finding a suitable scatter model. In this paper, an analytic scatter model has been proposed that is validated by a Monte Carlo simulation.

  15. Correction parameters in conventional dental radiography for dental implant

    Directory of Open Access Journals (Sweden)

    Barunawaty Yunus

    2009-12-01

    Full Text Available Background: Radiographic imaging as a supportive diagnostic tool is the essential component in treatment planning for dental implant. It help dentist to access target area of implant due to recommendation of many inventions in making radiographic imaging previously. Along with the progress of science and technology, the increasing demand of easier and simpler treatment method, a modern radiographic diagnostic for dental implant is needed. In fact, Makassar, especially in Faculty of Dentistry Hasanuddin University, has only a conventional dental radiography. Researcher wants to optimize the equipment that is used to obtain parameters of the jaw that has been corrected to get accurate dental implant. Purpose: This study aimed to see the difference of radiographic imaging of dental implant size which is going to be placed in patient before and after correction. Method: The type of research is analytical observational with cross sectional design. Sampling method is non random sampling. The amount of samples is 30 people, male and female, aged 20–50 years old. The correction value is evaluated from the parameter result of width, height, and thick of the jaw that were corrected with a metal ball by using conventional dental radiography to see the accuracy. Data is analyzed using SPSS 14 for Windows program with T-test analysis. Result: The result that is obtained by T-Test analysis results with significant value which p<0.05 in the width and height of panoramic radiography technique, the width and height of periapical radiography technique, and the thick of occlusal radiography technique before and after correction. Conclusion: It can be concluded that there is a significant difference before and after the results of panoramic, periapical, and occlusal radiography is corrected.

  16. Technical and clinical breast cancer screening performance indicators for computed radiography versus direct digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bosmans, Hilde; Lemmens, Kim; Zanca, Federica; Ongeval, Chantal van; Steen, Andre van [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Hauwere, An de; Thierens, Hubert [Ghent University, QCC, Ghent (Belgium); Herck, Koen van; Bleyen, Luc; Mortier, Griet [Ghent University, Centrum voor Preventie en Vroegtijdige Opsporing van Kanker, Department of Public Health, Ghent (Belgium); Martens, Patrick [Vroegtijdige Opsporing Borstklierkanker West-Vlaanderen vzw, Bruges (Belgium); Putte, Gretel vande; Kellen, Eliane; Limbergen, Erik van [Leuven University Center of Cancer Screening, Leuven (Belgium)

    2013-10-15

    To compare technical and clinical screening performance parameters between computed radiography (CR) and direct digital radiography (DR) systems. The number of women screened with CR was 73,008 and with DR 116,945. Technical and patient dose survey data of 25 CR and 37 DR systems were available. Technical performance was expressed by threshold thickness values at the mean glandular dose (MGD) level of routine practice. Clinical indicators included recall rate (RR), cancer detection rate (CDR), percentage of ductal carcinoma in situ (DCIS), percentage of cancers with T-scores smaller than 1 cm and positive predictive value (PPV). Contrast threshold values for the 0.1-mm gold disk were 1.44 {mu}m (SD 0.13 {mu}m) for CR and 1.20 {mu}m (SD 0.13 {mu}m for DR). MGD was 2.16 mGy (SD 0.36 mGy) and 1.35 mGy (SD 0.32 mGy) for CR and DR respectively. We obtained for CR, respectively DR, the following results: RR in the first round of 5.48 % versus 5.61 %; RR in subsequent rounds of 2.52 % versus 2.65 %; CDR of 0.52 % versus 0.53 %; DCIS of 0.08 % versus 0.11 %; a rate of cancers with T-scores smaller than 1 cm of 0.11 % versus 0.11 %; PPV of 18.45 % versus 18.64 %; none of them was significantly different. Our screening indicators are reassuring for the use of CR and DR, with CR operating at 60 % higher MGD. (orig.)

  17. Experiments on muon radiography with emulsion track detectors

    Directory of Open Access Journals (Sweden)

    Aleksandrov Andrey

    2016-01-01

    Full Text Available Muon radiography is a method of study the internal structure of large natural and industrial objects based on sensing an object with a flux of cosmic muons with their subsequent registration and analysis of the pattern of their dispersion, or conplete (or partial absorption. The Lebedev Physical Institute of the Russian Academy of Sciences and the Skobeltsyn Institute of Nuclear Physics of Moscow State University have started a series of muon radiography experiments with nuclear emulsion detectors. As a result, the optimal conditions for experiment arrangement have been determined, algorithms of data processing have been worked out, and peculiarities of the method have been ultimately investigated.

  18. Vibration Analysis of Digital Radiography System for Large Container Inspection

    Institute of Scientific and Technical Information of China (English)

    黄松岭; 李路明; 周立业; 向新程; 安继刚

    2003-01-01

    The cantilever vibration characteristics of a digital radiography system were analyzed to predict the effect of vibration on the performance of a mobile container inspection system. The static deformation,vibration mode and natural frequency of the cantilever of the digital radiography system were calculated with the ALGOR Finite Element System to verify the strength and rigidity of the cantilever. The maximum amplitude of the cantilever vibration occurs as it starts accelerating. The predictions show good agreement with test results, indicating that the finite element model of the cantilever structure accurately models the mechanical characteristics.

  19. Neutron radiography and tomography facility at IBR-2 reactor

    Science.gov (United States)

    Kozlenko, D. P.; Kichanov, S. E.; Lukin, E. V.; Rutkauskas, A. V.; Belushkin, A. V.; Bokuchava, G. D.; Savenko, B. N.

    2016-05-01

    An experimental station for investigations using neutron radiography and tomography was developed at the upgraded high-flux pulsed IBR-2 reactor. The 20 × 20 cm neutron beam is formed by the system of collimators with the characteristic parameter L/D varying from 200 to 2000. The detector system is based on a 6LiF/ZnS scintillation screen; images are recorded using a high-sensitivity video camera based on the high-resolution CCD matrix. The results of the first neutron radiography and tomography experiments at the developed facility are presented.

  20. Proton radiography, nuclear cross sections and multiple Coulomb scattering

    Energy Technology Data Exchange (ETDEWEB)

    Sjue, Sky K. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-04

    The principles behind proton radiography including multiple Coulomb scattering are discussed for a purely imaginary square well nucleus in the eikonal approximation. It is found that a very crude model can reproduce the angular dependence of the cross sections measured at 24 GeV/c. The largest differences are ~3% for the 4.56 mrad data, and ~4% for the 6.68 mrad data. The prospect of understanding how to model deterministically high-energy proton radiography over a very large range of energies is promising, but it should be tested more thoroughly.

  1. Detection of urinary stones at reduced radiation exposure: a phantom study comparing computed radiography and a low-dose digital radiography linear slit scanning system

    Science.gov (United States)

    Szucs-Farkas, Zsolt; Chakraborty, D. P.; Thoeny, Harriet C.; Loupatatzis, Christos; Vock, Peter; Harald, Bonel

    2010-01-01

    Objective In this experimental study we assessed the diagnostic performance of linear slit scanning radiography (LSSR) compared to conventional computed radiography (CR) in the detection of urinary calculi in an anthropomorphic phantom imitating patients weighing approximately 58 to 88 kg. Conclusion Compared to computed radiography, LSSR is superior in the detection of urinary stones and may be used for pretreatment localization and follow-up at a lower patient exposure. PMID:19457787

  2. The value of thyroid shielding in intraoral radiography

    NARCIS (Netherlands)

    Hoogeveen, R.C.; Hazenoot, B.; Sanderink, G.C.H.; Berkhout, W.E.R.

    2016-01-01

    Objectives: To evaluate the utility of the application of a thyroid shield in intraoral radiography when using rectangular collimation. Methods: Experimental data were obtained by measuring the absorbed dose at the position of the thyroid gland in a RANDO® (The Phantom Laboratory, Salem, NY) male ph

  3. Neutron induced electron radiography; Radiografia com eletrons induzida por neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Marcos Leandro Garcia

    2008-07-01

    In the present paper a new radiography technique, the 'Neutron Induced Electron Radiography' - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole no. 8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 {mu}m in 24 {mu}m of aluminum at a resolution of 32 {mu}m. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization. (author)

  4. Point Scattered Function (PScF) for fast neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hassan, Mohamed H. [Nuclear and Radiation Engineering Department, Alexandria University, Alexandria 21544 (Egypt)], E-mail: mhmheg@yahoo.com

    2009-08-01

    Fast neutron radiography opened up a new range of possibilities to image extremely dense objects. The removal of the scattering effect is one of the most challenging problems in neutron imaging. Neutron scattering in fast neutron radiography did not receive much attention compared with X-ray and thermal neutron radiography. The purpose of this work is to investigate the behavior of the Point Scattered Function (PScF) as applied in fast neutron radiography. The PScF was calculated using MCNP as a spatial distribution of scattered neutrons over the detector surface for one emitting source element. Armament and explosives materials, namely, Rifle steel, brass, aluminum and trinitrotoluene (TNT) were simulated. Effect of various sample thickness and sample-to-detector distance were considered. Simulated sample geometries included a slab with varying thickness, a sphere with varying radii, and a cylinder with varying base radii. Different neutron sources, namely, Cf-252, DT as well as DD neutron sources were considered. Neutron beams with zero degree divergence angle; and beams with varying angles related to the normal to the source plane were simulated. Curve fitting of the obtained PScF, in the form of Gaussian function, were given to be used in future work using image restoration codes. Analytical representation of the height as well as the Full Width at Half Maximum (FWHM) of the obtained Gaussian functions eliminates the need to calculate the PScF for sample parameters that were not investigated in this study.

  5. Trichobezoars Detected and Treated Based on Plain Radiography.

    Science.gov (United States)

    Barrows, Amy; Vachon, Tyler; Campin, Richard C; Ignacio, Romeo C

    2015-10-01

    Bezoars are conglomerations of indigestible material that become trapped in the gastrointestinal tract. We present a case of an 8-year-old female child diagnosed with a gastric bezoar solely on plain radiography and treated with abdominal surgical exploration and removal. In addition, traditional characteristic radiographic findings and treatment options for bezoars found in the current literature are reviewed.

  6. Pencil beam proton radiography using a multilayer ionization chamber

    NARCIS (Netherlands)

    Farace, Paolo; Righetto, Roberto; Meijers, Arturs

    2016-01-01

    A pencil beam proton radiography (PR) method, using a commercial multilayer ionization chamber (MLIC) integrated with a treatment planning system (TPS) was developed. A Giraffe (IBA Dosimetry) MLIC (+/- 0.5 mm accuracy) was used to obtain pencil beam PR by delivering spots uniformly positioned at a

  7. Chest radiography and abdominal ultrasound in general practice

    NARCIS (Netherlands)

    Speets, Anouk Mariëlle

    2006-01-01

    Chest radiography (CXR) and abdominal ultrasound (US) are two widely used diagnostic imaging techniques in Western societies. General practitioners (GPs) in The Netherlands annually request approximately 500,000 CXRs and 200,000 abdominal US, and therefore clearly place a burden on health care. Besi

  8. Common positioning errors in panoramic radiography: A review

    Energy Technology Data Exchange (ETDEWEB)

    Randon, Rafael Henrique Nunes [Stomathology and Oral Diagnostic Program, School of Dentistry of Sao Paulo, University of Sao Paulo, Sao Paulo (Brazil); Pereira, Yamba Carla Lara [Biology Dental Buco Graduate Program, School of Dentistry of Piracicaba, University of Campinas, Piracicaba (Brazil); Nascimento, Glauce Crivelaro do [Psychobiology Graduate Program, School of Philosophy, Science and Literature of Ribeirao Preto, University of Sao Paulo, Ribeirao Preto (Brazil)

    2014-03-15

    Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.

  9. comparison between sonographic and plain radiography in the ...

    African Journals Online (AJOL)

    hi-tech

    2003-10-10

    Oct 10, 2003 ... Senior Lecturer, Department of Radiology, Makerere University, ... Plain radiography made a diagnosis in 85.5% of patients and did ... abdominal pain, abdominal distension, vomiting and ... major draw back with the use of ultrasound is that it is .... Plain abdominal film demonstrates non-specific gaseous.

  10. Gonad shielding in paediatric pelvic radiography: disadvantages prevail over benefit

    NARCIS (Netherlands)

    Frantzen, M.J.; Robben, S.; Postma, A.A.; Zoetelief, J.; Wildberger, J.E.; Kemerink, G.J.

    2012-01-01

    Objective To re-evaluate gonad shielding in paediatric pelvic radiography in terms of attainable radiation risk reduction and associated loss of diagnostic information. Methods A study on patient dose and the quality of gonad shielding was performed retrospectively using 500 pelvic radiographs of ch

  11. Effect of comfort pads and incubator design on neonatal radiography

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xia; Baad, Michael; Reiser, Ingrid; Feinstein, Kate A.; Lu, Zhengfeng [University of Chicago Medicine, Department of Radiology, Chicago, IL (United States)

    2016-01-15

    There has been increasing interest in patient dose reduction in neonatal intensive care units. Removing comfort pads for radiography has been identified as a potential means to decrease patient dose. To assess the effect of comfort pads and support trays on detector entrance exposure (DEE) and image quality for neonatal radiography, and its implication for patient dose. Comfort pads and support trays from three incubator and warmer systems were examined. The attenuation of the primary beam by these structures was measured using a narrow beam geometry. Their effect on DEE and image quality was then assessed using typical neonatal chest radiography techniques with three configurations: (1) both the comfort pad and support included in the beam, (2) only the support tray included and (3) both the comfort pad and support tray removed. Comfort pads and support trays were found to attenuate the primary beam by 6-15%. Eliminating these structures from the X-ray beam's path was found to increase the detector entrance exposure by 28-36% and increase contrast-to-noise ratio by more than 21%, suggesting room for patient dose reduction when the same image quality is maintained. Comfort pads and tray support devices can have a considerable effect on DEE and image quality, with large variations among different incubator designs. Positioning the image detector directly underneath neonatal patients for radiography is a potential means for patient dose reduction. However, such benefit should be weighed against the risks of moving the patient. (orig.)

  12. Utility of lead thyroid collar in cephalometric radiography

    Directory of Open Access Journals (Sweden)

    Anuraag B Choudhary

    2012-01-01

    Conclusions : Lead shielding of the thyroid gland does not affect landmark identification or the specific measurements of the angulations traced during cephalometric analysis. TCs should be routinely applied during cephalometric radiography if cephalometric analyses are limited to the structures above the second cervical vertebra.

  13. The value of thyroid shielding in intraoral radiography

    NARCIS (Netherlands)

    Hoogeveen, R.C.; Hazenoot, B.; Sanderink, G.C.H.; Berkhout, W.E.R.

    2016-01-01

    Objectives: To evaluate the utility of the application of a thyroid shield in intraoral radiography when using rectangular collimation. Methods: Experimental data were obtained by measuring the absorbed dose at the position of the thyroid gland in a RANDO® (The Phantom Laboratory, Salem, NY) male ph

  14. Radiography Capabilities for Matter-Radiation Interactions in Extremes

    Energy Technology Data Exchange (ETDEWEB)

    Walstrom, Peter Lowell [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Garnett, Robert William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chapman, Catherine A. B [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Salazar, Harry Richard [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Otoole, Joseph Alfred [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Barber, Ronald L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Gomez, Tony Simon [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-04-28

    The Matter-Radiation Interactions in Extremes (MaRIE) experimental facility will be used to discover and design the advanced materials needed to meet 21st century national security and energy security challenges. This new facility will provide the new tools scientists need to develop next-generation materials that will perform predictably and on-demand for currently unattainable lifetimes in extreme environments. The MaRIE facility is based on upgrades to the existing LANSCE 800-MeV proton linac and a new 12-GeV electron linac and associated X-ray FEL to provide simultaneous multiple probe beams, and new experimental areas. In addition to the high-energy photon probe beam, both electron and proton radiography capabilities will be available at the MaRIE facility. Recently, detailed radiography system studies have been performed to develop conceptual layouts of high-magnification electron and proton radiography systems that can meet the experimental requirements for the expected first experiments to be performed at the facility. A description of the radiography systems, their performance requirements, and a proposed facility layout are presented.

  15. Assessment of panoramic radiography as a national oral examination tool: review of the literature

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo [School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2011-03-15

    The purpose of this review is to evaluate the possibility of panoramic radiography as a national oral examination tool. This report was carried out by review of the literatures. Panoramic radiography has sufficient diagnostic accuracy in dental caries, periodontal diseases, and other lesions. Also, the effective dose of panoramic radiography is lower than traditional full-mouth periapical radiography. Panoramic radiography will improve the efficacy of dental examination in national oral examination. However, more studies are required to evaluate the benefit, financial cost, and operation time and also to make selection criteria and quality management program.

  16. Endokrinologische Behandlung der Geschlechtsdysphorie bei Menschen mit Geschlechtsinkongruenz

    Directory of Open Access Journals (Sweden)

    Flütsch N

    2015-01-01

    Full Text Available Es gibt Menschen, die die innere Gewissheit besitzen, dass ihre Geschlechtsidentität nicht zu ihrem biologischen Ursprungsgeschlecht passt. Durch die Entwicklungen in der Medizin in den letzten hundert Jahren ist es möglich geworden, die körperlichen Geschlechtsmerkmale an das innerlich erlebte Geschlecht anzupassen. Die Zahl der Hilfesuchenden in den ärztlichen Ambulanzen und Privatpraxen hat in den vergangenen Jahren deutlich zugenommen. Das Vorgehen bei der Diagnostik und Therapieeinleitung erlebt zurzeit eine deutliche Veränderung hin zu mehr Patientenzentriertheit und Individualisierung des Transitionsprozesses. Dabei bildet die geschlechtsangleichende Hormontherapie ein wesentliches Standbein in der körperlichen Angleichung an das Gegengeschlecht. Unter Beachtung von bestimmten Sicherheitsaspekten ist eine Hormontherapie mit Sexualhormonen sicher und einfach durchzuführen. Regelmäßige Verlaufskontrollen sowie der offene und affirmative Umgang mit den Betroffenen tragen zudem wesentlich zur Sicherheit in der Behandlung bei.

  17. Supermarket refrigerators with natural refrigerants; Supermarktkaelteanlagen mit natuerlichen Kaeltemitteln. Erfahrungsbericht

    Energy Technology Data Exchange (ETDEWEB)

    Haaf, S.; Heinbokel, B. [Linde AG, Koeln (Germany). Gechaeftsbereich Linde Kaeltetechnik

    2002-09-01

    In view of the high contribution to global warming of H-CFC refrigerants, substitution has been a key concern for several years now. Leakage protection measures were enhanced, and Linde also installed many supermarket refrigerators with natural refrigerants, i.e. ammonia, propene and carbon dioxide. The environmental and economic aspects are assessed on the basis of the experience gained, and the systems are compared with H-CFC refrigeration systems. [German] Wegen des betraechtlichen Treibhauspotentials von HFKW-Kaeltemitteln werden seit Jahren Anstrengungen unternommen, um den von diesen Stoffen ausgehenden Treibhauseffekt zu reduzieren. Neben Massnahmen zur Verminderung von Leckagen sowie zur Verringerung von Kaeltemittel-Fuellmengen wurden im Laufe der letzten 10 Jahre von Linde auch zahlreiche Kaelteanlagen mit den natuerlichen Kaeltemitteln Ammoniak, Propen und Kohlendioxid in Supermaerkten installiert. Auf Basis der gesammelten Erfahrungen wird eine Einschaetzung der umweltspezifischen und wirtschaftlichen Aspekte im Vergleich zu Anlagen mit HFKW-Kaeltemitteln vorgenommen. (orig.)

  18. Therapiemonitoring mit bildgebenden Verfahren im modernen Management von Hirntumoren

    Directory of Open Access Journals (Sweden)

    Gerigk L

    2010-01-01

    Full Text Available Bildgebende Verfahren sind eine wichtige Grundlage der Therapieplanung und -kontrolle bei Hirntumoren. Bislang diente hierzu in erster Linie die Größenbeurteilung auf herkömmlichen morphologischen MRT-Aufnahmen. Sowohl zur besseren Therapieplanung und -kontrolle im Rahmen etablierter Therapieschemata als auch zur Evaluation neuer Therapieverfahren ist die Erfassung physiologischer Parameter wie der Perfusion, Diffusion oder Permeabilität mithilfe von MRT und PET eine vielversprechende Entwicklung. Mit der PET und entsprechenden Tracern können zusätzlich auch Targets zur Tumorklassifikation oder gezielten Therapie nachgewiesen werden. Mit der Spektroskopie können für Tumorgewebe typische Metabolite nachgewiesen werden. Bei einigen Tumorentitäten wie den niedergradigen Gliomen zeigten Studien, dass die Perfusionsbildgebung hilfreich zur Planung des weiteren therapeutischen Vorgehens sein kann. Ziel ist, durch eine Kombination geeigneter Verfahren zu einer frühen und treffsicheren Diagnostik beizutragen.

  19. MIT-Skywalker: Evaluating comfort of bicycle/saddle seat.

    Science.gov (United States)

    Goncalves, Rogerio S; Hamilton, Taya; Daher, Ali R; Hirai, Hiroaki; Krebs, Hermano I

    2017-07-01

    The MIT-Skywalker is a robotic device developed for the rehabilitation of gait and balance after a neurological injury. This device has been designed based on the concept of a passive walker and provides three distinct training modes: discrete movement, rhythmic movement, and balance training. In this paper, we present our efforts to evaluate the comfort of a bicycle/saddle seat design for the system's novel actuated body weight support device. We employed different bicycle and saddle seats and evaluated comfort using objective and subjective measures. Here we will summarize the results obtained from a study of fifteen healthy subjects and one stroke patient that led to the selection of a saddle seat design for the MIT-Skywalker.

  20. Hochauflösende Verarbeitung von Radardaten mit synthetischer Apertur

    OpenAIRE

    Mittermayer, Josef

    2006-01-01

    Diese Arbeit stellt das neuartige Frequenz-Skalierungs-Verfahren zur effizienten und genauen Verarbeitung von Spotlight-SAR-Daten ohne Interpolation vor. Es wird eine genaue Modellierung der Spotlight-Abbildungsgeometrie eingeführt. Eine neue analytische Formulierung für SAR-Rohdaten mit Dechirp on Receive-Operation wird abgeleitet. Aufbauend auf dieser Formulierung erfolgt die Entwicklung einer interpolationsfreien Korrektur der Zielentfernungsänderung, der sogenannten Frequenz-Skalierung. ...

  1. Unverarbeitete Trauer in Familien mit einem psychosomatisch kranken Kind

    OpenAIRE

    Perinelli, Karin; Günther, Charlotte

    1983-01-01

    In einer Untersuchungsstudie über die psychosoziale Abwehr in psychosomatischen Familien interessierte der Befund, daß Eltern von Kindern, die psychosomatisch erkrankt sind, weitaus häufiger als Eltern in einer Vergleichsgruppe frühe Personenverluste zu verkraften hatten, die sie heute empfindlich gegen Trennung machen. Es wird gezeigt, wie das Auftreten eines psychosomatischen Symptoms beim Kind mit unverarbeiteter Trauer in seiner Familie in Zusammenhang stehen konnte. Der von Minuchin für ...

  2. Phytoremediation organischer Schadstoffe mit Hilfe von Phragmites australis

    OpenAIRE

    Neustifter, Juliane Erika

    2007-01-01

    Praxisorientierte Projekte an einer Kläranlage lieferten umfassende Einblicke in einen mit Phragmites australis, dem Schilfrohr, bepflanzten Bodenfilter und seine jahreszeitlichen Rhythmen. Es wurde festgestellt, dass der Filter eine ausgezeichnete Restreinigung und Pufferwirkung hat und sogar verschiedene endokrin wirksame Substanzen zurückhält. Es konnte gezeigt werden, dass Phragmites australis organische Schadstoffe aufnehmen kann und wichtige Entgiftungsenzyme für den Abbau dieser Xenobi...

  3. Third Culture Kids? Auslandsentsendung mit Kindern und Jugendlichen

    OpenAIRE

    2006-01-01

    Die Arbeit untersucht die langfristigen Auswirkungen von Auslandsaufenthalten im Kindesalter. Das Interesse richtet sich auf die Frage, welche Rolle der Auslandsaufenthalt für die Identität im Erwachsenenalter spielt. Zu diesem Zweck wurden qualitative Interviews mit Erwachsenen geführt, die in ihren Entwicklungsjahren durch den Umzug von ihrem Ursprungsland in ein fremdes Land – und wieder zurück – Transitionserfahrungen gemacht haben.

  4. Topologie und Dynamische Netzwerke: Anwendungen Der Optimierung MIT Zukunft

    Science.gov (United States)

    Leugering, Günter; Martin, Alexander; Stingl, Michael

    Die optimale Auslegung von Infrastrukturen z. B. bei der Verkehrsplanung und bei der Planung von Versorgungssystemen, die optimale Strukturierung bzw. Formgebung von Materialien und Werkstücken z. B. im Leichtbau sind aktuelle Themen angewandter Forschung. In beiden Bereichen wurde bis in die jüngste Zeit vornehmlich eine simulationsbasierte Optimierung auf der Grundlage einer Parameterjustierung vorgenommen, die oft wenig systematisch und zeit- und kostenintensiv ist. Stattdessen erweisen sich modellbasierte mathematische Optimierungsalgorithmen zusammen mit moderner numerischer Simulations-und Visualisierungstechnologie zunehmend als Katalysator neuer Technologien. Eine so verstandene Mathematische Optimierung kann bereits auf beeindruckende Erfolgsgeschichten verweisen und so den Anspruch als eine Zukunftsdisziplin behaupten. Diesem Anspruch trägt die Einrichtung des DFG-Schwerpunktprogramms 1253, Optimierung mit partiellen Differentialgleichungen’ im Jahre 2006 Rechnung, in dem über 25 Projekte im Bundesgebiet sowohl auf die theoretische Fundierung, als auch und insbesondere auf die Verzahnung zwischen Methodenentwicklung und numerischer Realisierung fokussieren. Forschung im Bereich der mathematischen Optimierung und Steuerung von Prozessen bzw. Eigenschaften, die mit Hilfe partieller Differentialgleichungen, so genannten, verteilten Systemen’, beschrieben werden, erfolgt im Kontext konkreter und exemplarischer Anwendungssituationen, die neue mathematische Herausforderungen markieren: Sicherheitsvorgaben etwa bei der Belastung von Gas- und Frischwasserleitungen oder solche für die Belastbarkeit von Verkehrsflugzeugen führen auf Druckbeschränkungen bzw.

  5. Nagelbefall kann bei Patienten mit Psoriasis auf eine Enthesiopathie hinweisen.

    Science.gov (United States)

    Castellanos-González, Maria; Joven, Beatriz Esther; Sánchez, Julio; Andrés-Esteban, Eva María; Vanaclocha-Sebastián, Francisco; Romero, Pablo Ortiz; Díaz, Raquel Rivera

    2016-11-01

    Obwohl subklinische Enthesiopathie ein gut etabliertes diagnostisches Merkmal der Psoriasisarthritis (PsA) ist, wird sie häufig übersehen, da viele Patienten asymptomatisch sind. Gäbe es klinische Hinweise auf das Vorliegen einer Enthesiopathie, würde dies den Klinikern die Möglichkeit eröffnen, eine PsA frühzeitig zu diagnostizieren. Es wurde eine monozentrische prospektive Studie mit insgesamt 90 Psoriasis-Patienten durchgeführt, um mittels Ultraschall das Vorliegen von Enthesenanomalien zu untersuchen und eine Korrelation mit dem Befall der Nägel festzustellen. Enthesenanomalien wurden bei 23 Patienten (25,5 %) gefunden, von denen 19 (82,6 %) Nagelbefall aufwiesen. Bei 4 Patienten waren die Nägel nicht betroffen. Enthesiopathie lag bei 31,1 % (19/61) der Patienten mit Onychopathie vor, von den Patienten ohne Nagelbefall litten nur 13,8 % (4/29) an Enthesiopathie (p = 0,07). Zwischen dem Target-NAPSI-Score und dem Vorliegen einer Enthesiopathie bestand eine signifikante Korrelation. Eine signifikante Korrelation bestand darüber hinaus auch zwischen dem Vorliegen einer Enthesiopathie und der Anzahl der betroffenen Nägel (p = 0,035). Klinische Belege für eine Onychopathie können der Schlüssel für die frühe Diagnose einer Enthesiopathie bei Psoriasis-Patienten sein. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  6. Effective dose for patient in multimode panoramic radiography

    Energy Technology Data Exchange (ETDEWEB)

    Yasaki, Shiro; Daibo, Motoji [Ohu Univ., Koriyama, Fukushima (Japan). School of Dentistry

    1999-06-01

    In recent years, multimode panoramic radiography has had various functions, such as the auto exposure function, auto focus function (auto function), TMJ radiography and tomogram radiography functions. The purpose of this study was to estimate the effective dose for patients in each mode of the new multimode panoramic radiography (J. MORITA MFG. CORP. Dental Panorama X-ray Apparatus: Veraview Scope X 600). The absorbed doses in important organs involved in the causation of stochastic effects were measured by a thermoluminescent dosimeter using RANDO phantom. The effective doses were calculated using modified tissue weighting factors recommended by the International Commission on Radiological Protection (ICRP) in 1999. The mean field size over skin in typical panoramic and tomographic examinations was about 3% and 0.4% of the total body surface area of 15000 cm{sup 2}. Assuming that the incidence of skin cancer is proportional to the area of skin exposed to ionizing radiation, the tissue weighting factor of skin can be estimated to be about 0.0003 and 0.00004. The estimate in effective dose was lower (5.3 {mu}Sv) in the panoramic auto function mode (an average exposure condition of 69 kV 7 mA) than that (6.5-13.8 {mu}Sv) in the linear tomogram modes. Since the linear tomogram mode requires a scout view, such as standard panoramic radiography, the dose in the linear tomogram mode becomes higher than other modes. A percentage of gonad doses in effective doses was negligible. (author)

  7. National data analysis of general radiography projection method in medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su; Seo, Deok Nam; Choi, In Seok [Dept. of Bio-Convergence Engineering, Korea University Graduate School, Seoul (Korea, Republic of); and others

    2014-09-15

    According to database of medical institutions of health insurance review and assessment service in 2013, 1,118 hospitals and clinics have department of radiology in Korea. And there are CT, fluoroscopic and general radiographic equipment in those hospitals. Above all, general radiographic equipment is the most commonly used in the radiology department. And most of the general radiographic equipment are changing the digital radiography system from the film-screen types of the radiography system nowadays. However, most of the digital radiography department are used the film-screen types of the radiography system. Therefore, in this study, we confirmed present conditions of technical items for general radiography used in hospital and research on general radiographic techniques in domestic medical institutions. We analyzed 26 radiography projection method including chest, skull, spine and pelvis which are generally used in the radiography department.

  8. Phylogenetic relationships of the Gomphales based on nuc-25S-rDNA, mit-12S-rDNA, and mit-atp6-DNA combined sequences

    Science.gov (United States)

    Admir J. Giachini; Kentaro Hosaka; Eduardo Nouhra; Joseph Spatafora; James M. Trappe

    2010-01-01

    Phylogenetic relationships among Geastrales, Gomphales, Hysterangiales, and Phallales were estimated via combined sequences: nuclear large subunit ribosomal DNA (nuc-25S-rDNA), mitochondrial small subunit ribosomal DNA (mit-12S-rDNA), and mitochondrial atp6 DNA (mit-atp6-DNA). Eighty-one taxa comprising 19 genera and 58 species...

  9. Kasuistik 1: 62-jähriger Rentner mit Altershypogonadismus therapiert mit Pflaster und Gel im Vergleich

    Directory of Open Access Journals (Sweden)

    Behre HM

    2003-01-01

    Full Text Available 62-jähriger Rentner mit normogonadotropem Altershypogonadismus. Der Patient leidet seit 2 Jahren vermehrt unter Schweißausbrüchen und Hitzewallungen, Schlafstörungen, einer zunehmenden Leistungsminderung und einer Erektionsschwäche. Aufgrund des Altershypogonadismus wurde vor der Vorstellung in der andrologischen Sprechstunde vom Hausarzt eine Substitutionstherapie mit Androderm® 2 x 2,5 mg/d begonnen. Unter dieser Therapie wurden keine normwertigen Testosteron-Serumspiegel erreicht, da die Testosteronpflaster aufgrund vermehrten Schwitzens des Patienten nicht an der Haut haften. Bei den Kontrolluntersuchungen unter Androderm-Medikation sind die Testosteronwerte kontinuierlich im hypogonadalen Bereich (Ausgangswert: 3,7 nmol/l [Normbereich 12-35 nmol/l, Blutabnahmen jeweils am Morgen]; Kontrolluntersuchungen unter Androdermtherapie (ca. 12 Stunden nach Applikation: 4,9 nmol/l, 5,1 nmol/l. Unter der Androderm-Medikation besserten sich die oben beschriebenen Beschwerden nicht.

  10. Segmental lumbar spine instability at flexion-extension radiography can be predicted by conventional radiography

    Energy Technology Data Exchange (ETDEWEB)

    Pitkaenen, M.T.; Manninen, H.I.; Lindgren, K.-A.J.; Sihvonen, T.A.; Airaksinen, O.; Soimakallio, S

    2002-07-01

    AIM: To identify plain radiographic findings that predict segmental lumbar spine instability as shown by functional flexion-extension radiography. MATERIALS AND METHODS: Plain radiographs and flexion-extension radiographs of 215 patients with clinically suspected lumbar spine instability were analysed. Instability was classified into anterior or posterior sliding instability. The registered plain radiographic findings were traction spur, spondylarthrosis, arthrosis of facet joints, disc degeneration, retrolisthesis, degenerative spondylolisthesis, spondylolytic spondylolisthesis and vacuum phenomena. Factors reaching statistical significance in univariate analyses (P < 0.05) were included in stepwise multiple logistic regression analysis. RESULTS: Degenerative spondylolisthesis (P = 0.004 at L3-4 level and P = 0.017 at L4-5 level in univariate analysis and odds ratio 16.92 at L4-5 level in multiple logistic regression analyses) and spondylolytic spondylolisthesis (P = 0.003 at L5-S1 level in univariate analyses) were the strongest independent determinants of anterior sliding instability. Retrolisthesis (odds ratio 10.97), traction spur (odds ratio 4.45) and spondylarthrosis (odds ratio 3.20) at L3-4 level were statistically significant determinants of posterior sliding instability in multivariate analysis. CONCLUSION: Sliding instability is strongly associated with various plain radiographic findings. In mechanical back pain, functional flexion-extension radiographs should be limited to situations when symptoms are not explained by findings of plain radiographs and/or when they are likely to alter therapy. Pitkaenen, M.T. et al. (2002)

  11. Untersuchung von Verbesserungspotentialen hinsichtlich Verbrauch und Drehmoment bei Ottomotoren mit Hilfe 1-dimensionaler Simulationsrechnung

    OpenAIRE

    Schreiber, Gert

    2006-01-01

    Im Rahmen dieser Arbeit wurden verschiedene Verbesserungspotentiale von Ottomotoren mit besonderer Berücksichtigung von Verbrauch und Drehmoment mit Hilfe der Motorprozeßrechnung untersucht. Insbesondere wurden die Zusammenhänge von Ursache und Wirkung einzelner Verbesserungsmaßnahmen herausgestellt. Zur Modellierung realer Motoren wurde die Simulationssoftware GT-Power verwendet, wobei die Regelung über Matlab/Simulink vorgenommen wurde. Aber auch mit vereinfachten Rechenmodellen, die unter ...

  12. The development of form two mathematics i-Think module (Mi-T2)

    Science.gov (United States)

    Yao, Foo Jing; Abdullah, Mohd Faizal Nizam Lee; Tien, Lee Tien

    2017-05-01

    This study aims to develop a training module i-THINK Mathematics Form Two (Mi-T2) to increase the higher-order thinking skills of students. The Mi-T2 training module was built based on the Sidek Module Development Model (2001). Constructivist learning theory, cognitive learning theory, i-THINK map and higher order thinking skills were the building blocks of the module development. In this study, researcher determined the validity and reliability of Mi-T2 module. The design being used in this study was descriptive study. To determine the needs of Mi-T2 module, questionnaires and literature review were used to collect data. When the need of the module was determined, the module was built and a pilot study was conducted to test the reliability of the Mi-T2 module. The pilot study was conducted at a secondary school in North Kinta, Perak. A Form Two class was selected to be the sample study through clustered random sampling. The pilot study was conducted for two months and one topic had been studied. The Mi-T2 module was evaluated by five expert panels to determine the content validity of the module. The instruments being used in the study were questionnaires about the necessity of the Mi-T2 module for guidance, questionnaires about the validity of the module and questionnaires concerning the reliability of the module. Statistical analysis was conducted to determine the validity and reliability coefficients of the Mi-T2 module. The content validity of Mi-T2 module was determined by Cohen's Kappa's (1968) agreement coefficient and the reliability of Mi-T2 module was determined by Cronbach Alpha's value scale. The content validity of Mi-T2 module was 0.89 and the Cronbach Alpha's value of Mi-T2 module was 0.911.

  13. Delir, postoperative kognitive Verschlechterung und Charles Bonnet-Syndrom bei Patienten mit Kataraktoperationen

    OpenAIRE

    Hämmerl, Thomas

    2005-01-01

    In der Klinik für Augenheilkunde an der TU München wurden 92 Patienten mit Kataraktoperationen zu Delir, postoperativer kognitiver Verschlechterung und Charles Bonnet-Syndrom untersucht. Ein Patient hatte ein Delir bei Aufnahme, keiner entwickelte ein postoperatives Delir. Eine Risikogruppe für einen komplizierten postoperativen Verlauf stellten die Patienten mit präoperativer kognitiver Beeinträchtigung (n=11) und die Patienten mit postoperativer kognitiver Verschlechterung (n=8) dar. Risiko...

  14. Interaktion systemisch wirksamer Antimykotika mit der Aggregation humaner Thrombozyten in vitro

    OpenAIRE

    2011-01-01

    Patienten mit Krebserkrankungen und invasiven Pilzinfektionen haben ein hohes Risiko für Blutungen sowohl aufgrund verminderter Thrombozytenzahlen als auch der Neigung einiger Pilze zur Gefäßarrosion. In dieser Studie wurde Blut von zehn gesunden Freiwilligen in vitro mit den i.v.-Zubereitungen von 11 verschiedenen Antimykotika versetzt. Anschließend wurde die Thrombozytenaggregation mit der Methode der Impedanzaggregometrie untersucht. Amphotericin B Colloidal Dispersion, Amphotericin B ...

  15. Wirksamkeit und Sicherheit von Fumarsäureestern in Kombination mit Phototherapie bei Patienten mit moderater bis schwerer Plaque-Psoriasis (FAST).

    Science.gov (United States)

    Weisenseel, Peter; Reich, Kristian; Griemberg, Wiebke; Merten, Katharina; Gröschel, Christine; Gomez, Natalie Nunez; Taipale, Kirsi; Bräu, Beate; Zschocke, Ina

    2017-02-01

    Die Behandlung von Psoriasis-Patienten mit einer Kombination aus Fumarsäureestern (FSE, Fumaderm(®) ) und Phototherapie (UV) ist verbreitet, wurde aber im Rahmen von Studien wenig untersucht. Bisher liegen lediglich Daten aus einer kleinen Pilotstudie vor. Intention dieser Studie war, eine FSE/UV-Kombinationsbehandlung an einem größeren Patientenkollektiv mit mittelschwerer bis schwerer Psoriasis zu untersuchen. In dieser prospektiven, multizentrischen, nichtinterventionellen Studie wurden Daten von Patienten mit FSE/UV-Kombinationstherapie hinsichtlich der Wirksamkeit (PGA' PASI, DLQI, EQ-5D), Sicherheit und Dosierung über einen Zeitraum von zwölf Monaten erfasst und mit Daten einer retrospektiven Studie mit FSE-Monotherapie verglichen. Es wurden Daten von 363 Patienten ausgewertet. Unter der Kombinationstherapie verbesserten sich alle Wirksamkeitsparameter deutlich. Im Vergleich zur Monotherapie mit FSE konnte durch die Kombination mit UV ein schnellerer Wirkeintritt erzielt werden, wobei nach zwölf Monaten kein Unterschied in der Wirksamkeit bestand. Die Dauer und Art der Phototherapie zeigte keinen Einfluss auf die Wirksamkeitsparameter. Allgemein wurde die Kombinationstherapie gut vertragen. Unerwünschte Ereignisse wurden bei 7 % der Patienten berichtet. Die FSE/UV Kombinationstherapie zeigt eine gute Wirksamkeit und Verträglichkeit und kann zu einem schnelleren Wirkeintritt führen. Eine Kombinationstherapie erscheint vor allem in den ersten drei Monaten der FSE Behandlung sinnvoll. © 2017 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  16. Dose in conventional radiography; Dosis en radiografia convencional

    Energy Technology Data Exchange (ETDEWEB)

    Acuna D, E.; Padilla R, Z. P.; Escareno J, E.; Vega C, H. R. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98000 Zacatecas (Mexico)

    2011-10-15

    It has been pointed out that medical exposures are the most significant sources of exposure to ionizing radiation for the general population. Inside the medical exposures the most important is the X-ray use for diagnosis, which is by far the largest contribution to the average dose received by the population. From all studies performed in radiology the chest radiography is the most abundant. In an X-ray machine, voltage and current are combined to obtain a good image and a reduce dose, however due to the workload in a radiology service individual dose is not monitored. In order to evaluate the dose due to chest radiography in this work a plate phantom was built according to the ISO recommendations using methylmethacrylate walls and water. The phantom was used in the Imaging department of the Zacatecas General Hospital as a radiology patient asking for a chest study; using thermoluminescent dosimeters, TLD 100 the kerma at the surface entrance was determined. (Author)

  17. Computer-aided diagnosis in chest radiography: Beyond nodules

    Energy Technology Data Exchange (ETDEWEB)

    Ginneken, Bram van [University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)], E-mail: bram@isi.uu.nl; Hogeweg, Laurens; Prokop, Mathias [University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

    2009-11-15

    Chest radiographs are the most common exam in radiology. They are essential for the management of various diseases associated with high mortality and morbidity and display a wide range of findings, many of them subtle. In this survey we identify a number of areas beyond pulmonary nodules that could benefit from computer-aided detection and diagnosis (CAD) in chest radiography. These include interstitial infiltrates, catheter tip detection, size measurements, detection of pneumothorax and detection and quantification of emphysema. Recent work in these areas is surveyed, but we conclude that the amount of research devoted to these topics is modest. Reasons for the slow pace of CAD development in chest radiography beyond nodules are discussed.

  18. Application of imaging plate neutron detector to neutron radiography

    CERN Document Server

    Fujine, S; Kamata, M; Etoh, M

    1999-01-01

    As an imaging plate neutron detector (IP-ND) has been available for thermal neutron radiography (TNR) which has high resolution, high sensitivity and wide range, some basic characteristics of the IP-ND system were measured at the E-2 facility of the KUR. After basic performances of the IP were studied, images with high quality were obtained at a neutron fluence of 2 to 7x10 sup 8 n cm sup - sup 2. It was found that the IP-ND system with Gd sub 2 O sub 3 as a neutron converter material has a higher sensitivity to gamma-ray than that of a conventional film method. As a successful example, clear radiographs of the flat view for the fuel side plates with boron burnable poison were obtained. An application of the IP-ND system to neutron radiography (NR) is presented in this paper.

  19. A new scanner for in situ digital radiography of paintings

    Science.gov (United States)

    Impallaria, Anna; Evangelisti, Federico; Petrucci, Ferruccio; Tisato, Flavia; Castelli, Lisa; Taccetti, Francesco

    2016-12-01

    X-ray radiography is one of the most widely used imaging techniques in the field of cultural heritage, both for conservation and for investigation purposes. Performing radiographies in museums, thus avoiding movements of works of art, has been recently made easy by digital acquisition of images, but when the whole scan of a large painting is required, technical solutions for a portable device are still not at hand. The inherent weight of the X-ray tube and of the high-voltage generator makes the design of a portable device very difficult. In this project, the solution of the puzzle was separating devices devoted to different tasks, in order to maintain each item under 60 kg weight, thus being transportable with reasonable effort.

  20. The MU-RAY detector for muon radiography of volcanoes

    Energy Technology Data Exchange (ETDEWEB)

    Anastasio, A. [INFN-Napoli (Italy); Ambrosino, F. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); Basta, D. [INFN-Napoli (Italy); Bonechi, L. [Università degli Studi di Firenze, Firenze (Italy); INFN-Firenze (Italy); Brianzi, M. [Università degli Studi di Firenze, Firenze (Italy); Bross, A. [Fermilab (United States); Callier, S. [LAL, Orsay (France); Caputo, A. [INGV Osservatorio Vesuviano, Napoli (Italy); Ciaranfi, R. [INFN-Firenze (Italy); Cimmino, L. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); D' Alessandro, R. [Università degli Studi di Firenze, Firenze (Italy); INFN-Firenze (Italy); D' Auria, L. [INGV Osservatorio Vesuviano, Napoli (Italy); La Taille, C. de [LAL, Orsay (France); Energico, S. [CNR- SPIN, Napoli (Italy); INFN-Napoli (Italy); Garufi, F. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); Giudicepietro, F. [INGV Osservatorio Vesuviano, Napoli (Italy); Lauria, A. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); Macedonio, G.; Martini, M. [INGV Osservatorio Vesuviano, Napoli (Italy); Masone, V. [Università Federico II, Napoli (Italy); and others

    2013-12-21

    The MU-RAY detector has been designed to perform muon radiography of volcanoes. The possible use on the field introduces several constraints. First the electric power consumption must be reduced to the minimum, so that the detector can be solar-powered. Moreover it must be robust and transportable, for what concerns the front-end electronics and data acquisition. A 1 m{sup 2} prototype has been constructed and is taking data at Mt. Vesuvius. The detector consists of modules of 32 scintillator bars with wave length shifting fibers and silicon photomultiplier read-out. A dedicated front-end electronics has been developed, based on the SPIROC ASIC. An introduction to muon radiography principles, the MU-RAY detector description and results obtained in laboratory will be presented.

  1. Proton radiography and tomography with application to proton therapy

    Science.gov (United States)

    Allinson, N M; Evans, P M

    2015-01-01

    Proton radiography and tomography have long promised benefit for proton therapy. Their first suggestion was in the early 1960s and the first published proton radiographs and CT images appeared in the late 1960s and 1970s, respectively. More than just providing anatomical images, proton transmission imaging provides the potential for the more accurate estimation of stopping-power ratio inside a patient and hence improved treatment planning and verification. With the recent explosion in growth of clinical proton therapy facilities, the time is perhaps ripe for the imaging modality to come to the fore. Yet many technical challenges remain to be solved before proton CT scanners become commonplace in the clinic. Research and development in this field is currently more active than at any time with several prototype designs emerging. This review introduces the principles of proton radiography and tomography, their historical developments, the raft of modern prototype systems and the primary design issues. PMID:26043157

  2. Advancement of neutron radiography technique in JRR-3M

    Energy Technology Data Exchange (ETDEWEB)

    Matsubayashi, Masahito [Center for Neutron Science, Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

    1999-08-01

    The JRR-3M thermal neutron radiography facility (JRR-3M TNRF) was completed in the JRR-3M of the Japan Atomic Energy Research Institute in 1991 and has been utilized as research tools for various kinds of research fields such as thermal hydraulic researches, agricultural researches, medical researches, archaeological researches and so on. High performance of the JRR-3M TNRF such as high neutron flux, high collimator ratio and wide radiographing field has enabled advanced researches and stimulated developments of advanced neutron radiography (NR) systems for higher spatial resolution and for higher temporal resolution. Static NR systems using neutron imaging plates or cooled CCD camera with high spatial resolution, a real-time NR system using a silicon intensifier target tube camera and a high-frame-rate NR system using a combination of an image intensifier and a high speed digital video camera with high temporal resolution have been developed to fill the requirements from researchers. (author)

  3. Diagnostic ability of panoramic radiography for mandibular fractures

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Hyun; Jung, Yun Hoa; Cho Bong Hae; Hwang, Dae Seok [School of Dentistry, Pusan National University, Pusan (Korea, Republic of)

    2010-03-15

    The purpose of this study was to evaluate the diagnostic efficacy of panoramic radiographs for detection of mandibular fractures. The sample was comprised of 65 patients (55 fractured, 10 non-fractured) with 92 fracture sites confirmed by multi-detector computed tomography (CT). Panoramic radiographs were evaluated for mandibular fractures by six examiners; two oral and maxillofacial radiologists (observer A and B), two oral and maxillofacial surgeons (observer C and D), and two general dentists (observer E and F). Sensitivity of panoramic radiography for mandibular fractures was 95.7% in observer A and B, 93.5% in observer C and D and 80.4% in observer E and F. The lowest sensitivity was shown in symphyseal/parasymphyseal areas, followed by subcondylar/condylar regions. Panoramic radiography is adequate for detection of mandibular fractures. However, additional multidetector CT is recommended to ascertain some indecisive fractures of symphysis and condyle, and in complicated fractures.

  4. Human performance analysis of industrial radiography radiation exposure events

    Energy Technology Data Exchange (ETDEWEB)

    Reece, W.J.; Hill, S.G.

    1995-12-01

    A set of radiation overexposure event reports were reviewed as part of a program to examine human performance in industrial radiography for the US Nuclear Regulatory Commission. Incident records for a seven year period were retrieved from an event database. Ninety-five exposure events were initially categorized and sorted for further analysis. Descriptive models were applied to a subset of severe overexposure events. Modeling included: (1) operational sequence tables to outline the key human actions and interactions with equipment, (2) human reliability event trees, (3) an application of an information processing failures model, and (4) an extrapolated use of the error influences and effects diagram. Results of the modeling analyses provided insights into the industrial radiography task and suggested areas for further action and study to decrease overexposures.

  5. Digital radiography: update for oral health care workers.

    Science.gov (United States)

    Noffke, C E E; Nzima, N; Chabikuli, N J

    2004-08-01

    Digital Radiography is an imaging system that does away with the use of films. It constitutes an advance in computer technology and has made a significant impact on the field of Maxillofacial- and Dental Radiology. This paper presents an overview of the basic concepts and applications of dental digital radiography and compares it with conventional film-based imaging. In addition, it provides a thorough understanding of the direct, semi-direct and indirect dental digital imaging systems with their advantages and disadvantages. Universal acceptance of digital radiographic imaging as a diagnostic tool makes it important for oral health care workers to understand the principles thereof and to master the techniques involved in acquiring a diagnosable digital radiographic image.

  6. Application of computed radiography for power plant tube

    Energy Technology Data Exchange (ETDEWEB)

    Chnag, Hee Jun; Kim, Sun Je; Yang, Yun Sick; Kim, Jong Duck; Lim, Sung Hee [Dosan Heavey Industries and Constrution Co.,Ltd, Changwon (Korea, Republic of); Park, Young Ha [Shinki Commercial Co.,Ltd, Seoul (Korea, Republic of)

    2005-05-15

    For radiographic examination, it is imperative that the film characteristics be determined so that optimal test conditions, and the result thereof, can be verified by analyzing the film values with regard to different radiation sources, and for standardizing the characteristics such as sensitivity, exposure thickness range (latitude) and maximum and minimum exposure dose, The research presented in this paper was aimed at evaluating the radioactive sensitivity characteristics of the Image Plate, in lieu of film, as used in Computer Radiography for various radiation sources, in order to apply this newly developed technology in other industrial fields, and in particular, the Power Plant industry. Several possibilities and improvements were discovered with the substitution of Computer Radiography for Conventional Film Radiographic Test.

  7. First results on proton radiography with nuclear emulsion detectors

    CERN Document Server

    Braccini, S; Kreslo, I; Moser, U; Pistillo, C; Studer, S; Scampoli, P; Coray, A; Pedroni, E

    2010-01-01

    We propose an innovative method for proton radiography based on nuclear emulsion film detectors, a technique in which images are obtained by measuring the position and the residual range of protons passing through the patient's body. For this purpose, nuclear emulsion films interleaved with tissue equivalent absorbers can be used to reconstruct proton tracks with very high accuracy. This is performed through a fully automated scanning procedure employing optical microscopy, routinely used in neutrino physics experiments. Proton radiography can be used in proton therapy to obtain direct information on the average tissue density for treatment planning optimization and to perform imaging with very low dose to the patient. The first prototype of a nuclear emulsion based detector has been conceived, constructed and tested with a therapeutic proton beam. The first promising experimental results have been obtained by imaging simple phantoms.

  8. A new scanner for in situ digital radiography of paintings

    Energy Technology Data Exchange (ETDEWEB)

    Impallaria, Anna; Petrucci, Ferruccio; Tisato, Flavia [University of Ferrara, Department of Physics and Earth Science, Ferrara (Italy); TekneHub Ferrara, Ferrara (Italy); INFN-Sezione di Ferrara, Ferrara (Italy); Evangelisti, Federico [University of Ferrara, Department of Physics and Earth Science, Ferrara (Italy); INFN-Sezione di Ferrara, Ferrara (Italy); Castelli, Lisa; Taccetti, Francesco [INFN-Sezione di Firenze, Sesto Fiorentino (Italy)

    2016-12-15

    X-ray radiography is one of the most widely used imaging techniques in the field of cultural heritage, both for conservation and for investigation purposes. Performing radiographies in museums, thus avoiding movements of works of art, has been recently made easy by digital acquisition of images, but when the whole scan of a large painting is required, technical solutions for a portable device are still not at hand. The inherent weight of the X-ray tube and of the high-voltage generator makes the design of a portable device very difficult. In this project, the solution of the puzzle was separating devices devoted to different tasks, in order to maintain each item under 60 kg weight, thus being transportable with reasonable effort. (orig.)

  9. Developing the profession of radiography: Making use of oral history

    Energy Technology Data Exchange (ETDEWEB)

    Decker, Sola [School of Radiography, Faculty of Nursing, Midwifery and Health Studies, University of Wales, Bangor, Archimedes Centre, Technology Park, Wrexham LL13 7YP (United Kingdom)]. E-mail: rdsa01@bangor.ac.uk; Iphofen, Ron [Faculty of Nursing, Midwifery and Health Studies, University of Wales, Bangor, Archimedes Centre, Technology Park, Wrexham LL13 7YP (United Kingdom)

    2005-11-01

    This paper is based on ongoing research into the profession of radiography using the oral history method. Knowledge of radiographic practice as a profession has in the past been based on what is written or learnt from other professions both within and beyond the field of health care. The profession has experienced substantial technological and sociological changes both in training and in practice over the past few decades and these look set to continue into the immediate future. Evidence-based practice is invoked as a quality measure on all health professions, and part of the body of knowledge which forms the evidence base of practice development involves an understanding of how the profession has responded to change and what this might mean for the further changes it is likely to meet. This paper explores the potential role of oral history research as a tool for the development of knowledge about the practice of radiography.

  10. Kompressionstherapie - Versorgungspraxis: Informationsstand von Patienten mit Ulcus cruris venosum.

    Science.gov (United States)

    Protz, Kerstin; Heyer, Kristina; Dissemond, Joachim; Temme, Barbara; Münter, Karl-Christian; Verheyen-Cronau, Ida; Klose, Katharina; Hampel-Kalthoff, Carsten; Augustin, Matthias

    2016-12-01

    Eine Säule der kausalen Therapie bei Patienten mit Ulcus cruris venosum ist die Kompressionstherapie. Sie unterstützt die Abheilung, reduziert Schmerzen und Rezidive und steigert die Lebensqualität. Bislang existieren kaum wissenschaftliche Daten zu dem Versorgungsstand und fachspezifischem Wissen von Patienten mit Ulcus cruris venosum. Standardisierte Fragebögen wurden bundesweit in 55 Pflegediensten, 32 Arztpraxen, vier Wundzentren und -sprechstunden sowie einem Pflegetherapiestützpunkt von Patienten mit Ulcus cruris venosum bei Erstvorstellung anonym ausgefüllt. Insgesamt nahmen 177 Patienten (Durchschnittsalter 69,4 Jahre; 75,1 % Frauen) teil. Ein florides Ulcus cruris venosum bestand im Mittel 17 Monate. 31,1 % hatten keine Kompressionstherapie, 40,1 % Binden und 28,8 % Strümpfe. Bei der Bestrumpfung hatten 13,7 % Kompressionsklasse III, 64,7 % Kompressionsklasse II und 19,6 % Kompressionsklasse I. 70,6 % legten die Strümpfe nach dem Aufstehen an, 21,1 % trugen sie Tag und Nacht. 39,2 % bereiteten die Strümpfe Beschwerden. Lediglich 11,7 % hatten eine An- und Ausziehhilfe. Die Binden wurden im Mittel 40,7 Wochen getragen und bei 69 % nicht unterpolstert. Bei 2,8 % wurde der Knöchel- und Waden-Umfang zur Erfolgskontrolle gemessen. Venensport machten 45,9 %. Ein Drittel hatte keine Kompressionsversorgung, obwohl diese eine Basismaßnahme der Therapie des Ulcus cruris venosum ist. Zudem ist deren korrekte Auswahl und Anwendung angesichts der langen Bestandsdauer der Ulzerationen zu hinterfragen. Weiterführende Fachkenntnisse bei Anwendern und Verordnern sowie Patientenschulungen sind erforderlich. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  11. Turnover Rate Simulation Using GEM Detector on Neutron Radiography

    Institute of Scientific and Technical Information of China (English)

    SHAN; Chao; LI; Xiao-mei; HU; Shou-yang; ZHOU; Jing; JIAN; Si-yu; BAI; Xin-zhan; YE; Li; ZHOU; Shu-hua

    2012-01-01

    <正>With the advantages of high counting rate, high resolution ratio and high compatibility, GEM (Gas Electron Multiplier) detector has becoming the hot topic in the field of gas detector. Using GEM on neutron radiography, we need a suitable neutron converter. By the action on the converter and ingoing neutron, the outgoing particles could be an alpha or proton, which are charged particles. The charged

  12. Subtraction Radiography for the Diagnosis of Bone Lesions in Dogs.

    Science.gov (United States)

    1984-05-31

    Avail ander Journal of Periodontology Dist Special Ř 211 East Chicago Avenue Room 924 Chicago, IL 60611 Dear Sirs: I m submitting an original...research article titled "Subtraction Radiography for the Diagnosis of Bone Lesions in Dogs" solely to the Journal of Periodontology for review and... clinical practice in our area. 60-70 Kvp would have produced more contrast in the radiographic films used for the conventional technique, but likely

  13. Absorbed radiation by various tissues during simulated endodontic radiography

    Energy Technology Data Exchange (ETDEWEB)

    Torabinejad, M.; Danforth, R.; Andrews, K.; Chan, C.

    1989-06-01

    The amount of absorbed radiation by various organs was determined by placing lithium fluoride thermoluminescent chip dosimeters at selected anatomical sites in and on a human-like X-ray phantom and exposing them to radiation at 70- and 90-kV X-ray peaks during simulated endodontic radiography. The mean exposure dose was determined for each anatomical site. The results show that endodontic X-ray doses received by patients are low when compared with other radiographic procedures.

  14. Development of imaging techniques for fast neutron radiography in Japan

    CERN Document Server

    Fujine, S; Yoshii, K; Kamata, M; Tamaki, M; Ohkubo, K; Ikeda, Y; Kobayashi, H

    1999-01-01

    Neutron radiography with fast neutron beams (FNR) has been studied at the fast neutron source reactor 'YAYOI' of the University of Tokyo since 1986. Imaging techniques for FNR have been developed for CR-39 track-etch detector, electronic imaging system (television method), direct film method, imaging plate and also fast and thermal neutron concurrent imaging method. The review of FNR imaging techniques and some applications are reported in this paper.

  15. Review and Prospect of Cobalt-60 Digital Radiography Inspection Technology

    OpenAIRE

    AN Ji-gang

    2015-01-01

    This article is a review and prospect of the research, development and industrialization of Cobalt-60 digital radiography inspection technology based on the national requirements in the recent 20 years, which is leaded by Institute of Nuclear and New Energy Technology (INET) of TsinghuaUniversity. The research purpose, innovative approach and main academic achievements of this technology were described systematically. The industrial equipment varieties, performance, running condition and appl...

  16. Real-time radiography at the NECTAR facility

    Energy Technology Data Exchange (ETDEWEB)

    Buecherl, T., E-mail: thomas.buecherl@radiochemie.de [Lehrstuhl fuer Radiochemie (RCM), Technische Universitaet Muenchen (TUM), Walther-Meissner-Str. 3, 85748 Garching (Germany); Lierse von Gostomski, Ch. [Lehrstuhl fuer Radiochemie (RCM), Technische Universitaet Muenchen (TUM), Walther-Meissner-Str. 3, 85748 Garching (Germany)

    2011-09-21

    A feasibility study has shown that real-time radiography using fission neutrons is possible at the NECTAR facility, when using an improved detection system for fast variations (Buecherl et al., 2009 ). Continuing this study, real-time measurements of slowly varying processes like the water uptake in medium sized trunks (diameter about 12 cm) and of slow periodic processes (e.g. a slowly rotating iron disk) are investigated successfully using the existing detection system.

  17. Dose Reduction to the Thyroid Gland in Pediatric Chest Radiography

    Directory of Open Access Journals (Sweden)

    Vahid Karami

    2016-07-01

    Full Text Available Background  It is remain a main concern that pediatric chest radiographies contribute to the significant radiation exposure to the thyroid gland as a more susceptible organ to radiation induced cancer. The aim of this study was to evaluate the entrance surface dose (ESD of pediatric chest radiography compared to the diagnostic reference levels (DRL and evaluation the efficacy of the lead (Pb shield in radiation dose reduction to the thyroid gland.Materials and Methods After assessing each patient against specific inclusion-exclusion criteria, 40 pediatric patients who were undergoing anterior-posterior (AP projection of the chest x-ray were considered eligible for this study. The ESD of the chest and also ESD of thyroid gland with and without a 1 mm butterfly-shaped lead shield which placed on the thyroid gland were measured using high sensitive thermo luminescent dosimeters (TLD-GR 200.Results The average of ESD for chest radiography was 0.068+ 0.006 mGy (0.021 - 0.232 mGy. The unshielded average thyroid ESD was 0.065 + 0.003 mGy compared to the shielded average thyroid ESD of 0.001 + 0.0005 mGy. The use of Pb-shield produced a statistically significant decrease in the average thyroid dose by about 97% (P< 0.001. Conclusion The use of Pb-thyroid shield in the AP projection of pediatric chest radiography has potential to reduced radiation dose without compromising image quality.

  18. Practical guidelines for radiographers to improve computed radiography image quality

    OpenAIRE

    Pongnapang, N

    2005-01-01

    Computed Radiography (CR) has become a major digital imaging modality in a modern radiological department. CR system changes workflow from the conventional way of using film/screen by employing photostimulable phosphor plate technology. This results in the changing perspectives of technical, artefacts and quality control issues in radiology departments. Guidelines for better image quality in digital medical enterprise include professional guidelines for users and the quality control programme...

  19. ADVANCEMENTS IN NEUTRON RADIOGRAPHY WITHIN THE DEPARTMENT OF THE ARMY

    Science.gov (United States)

    2016-11-01

    Carlo N-particle (MCNP) simulation software. The modeling confirmed that acceptable dose rates would be achieved outside of the shooting cell and...advanced nondestructive testing (NDT) technologies and inspections. Within the past five years, neutron radiography (NR) has been a main focus of...development where previous commercial off the shelf systems were inadequate to use. An increase in inspection technology was desired due to the rising need

  20. Fallstudie zur Informationskompetenz beim Lernen mit neuen Medien

    Directory of Open Access Journals (Sweden)

    Udo Hinze

    2017-08-01

    Full Text Available In der Debatte um die Medienkompetenz werden zunehmend die neuen Medien als unterstützende Mittel im E-Learningprozess thematisiert. Das selbstgesteuerte und flexible E-Learning ist auf eine hohe Handlungskompetenz der Lernenden angewiesen. Diese umfasst insbesondere die Fähigkeit, Informationen zu recherchieren, zu evaluieren und zu reduzieren. In einer Fallstudie wird exemplarisch aufgezeigt, wie sich divergente Kompetenz im Umgang mit Informationen manifestiert. Außerdem werden die Auswirkungen auf den Lernerfolg, die Lernzufriedenheit und die Nutzungsmodi der Medien dargestellt.

  1. Mit Mathematik zu Mehr Intelligenz in der Logistik

    Science.gov (United States)

    Möhring, Rolf H.; Schenk, Michael

    Die Lösung logistischer Probleme ist ein wichtiger Aspekt menschlichen Handelns seit Menschen gemeinsam zielgerichtet tätig wurden. Die Grundlagen dessen, was wir heute Logistik nennen, entstammen dem militärischen Bereich. So basierte z. B. das römische Imperium in starkem Maße auf militärisch-logistischen Glanzleistungen. Ob damals bereits mathematische Überlegungen eine Rolle spielten, wissen wir heute nicht. Jedoch versuchte z. B. Napoleon, der mit den bedeutendsten Mathematikern seiner Zeit befreundet war, den Transport seiner Truppen und die Verbreitung von Informationen zu optimieren und strategisch einzusetzen.1,2

  2. Therapie des metastasierten kastrationsresistenten Prostatakarzinoms mit Abirateronacetat im klinischen Alltag.

    Science.gov (United States)

    Wolff, Johannes Maria

    2017-01-01

    Abirateronacetat, das in Kombination mit Prednison/Prednisolon verabreicht wird, spielt eine wichtige Rolle in der Therapie des metastasierten kastrationsresistenten Prostatakarzinoms. Im Folgenden wurden besondere Aspekte der Therapie im klinischen Alltag zusammengestellt. Sie betreffen unter anderem die Dosierung - auch vor dem Hintergrund der Markteinführung einer neuen Formulierung von Abirateronacetat. Hinzu kommt die Verträglichkeit, vor allem in Bezug auf kardiovaskuläre und Kortikoid-bedingte Nebenwirkungen. Des Weiteren werden Kriterien genannt, nach denen die Therapie nicht zu früh umgestellt werden sollte. © 2017 S. Karger GmbH, Freiburg.

  3. Antikoagulation bei Vorhofflimmern: Wie und mit welchem Medikament?

    Directory of Open Access Journals (Sweden)

    Gary T

    2015-01-01

    Full Text Available Direkte orale Antikoagulantien (DOAKs sind Alternativen zu Vitamin-K-Antagonisten (VKA bei Vorhofflimmerarrhythmie- (VHFA- Patienten und werden diese in dieser Indikation zu weiten Teilen ersetzen. Bei VHFA-Patienten mit Dialyse oder mechanischen Herzklappen sind VKA nach wie vor die einzige Option. Bei der Gabe von DOAKs sollte vor Therapieeinleitung auf das Vorhandensein von Begleiterkrankungen (z. B. Niereninsuffizienz, stattgehabte gastrointestinale Blutungen etc. sowie auf die Begleittherapie der Patienten (z. B. Amiodaron etc. geachtet werden, um die passende Substanz in der richtigen Dosierung zu wählen.

  4. Innovative facades with photovoltaics; Innovative Fassaden mit Photovoltaik

    Energy Technology Data Exchange (ETDEWEB)

    Eicker, U. [Hochschule fuer Technik, Stuttgart (Germany)

    1999-10-01

    Having grown at a rate of 15% since the middle of the 1980s the photovoltaic market today commands an annual module production of more than 100 MW{sub p}. In Germany altogether 10,000 PV systems with a total power output of 10 MW{sub p} were newly installed in 1997 alone. In 1990 the market was boosted by the heavily subsidised 1000 roofs programme, under which in the end more than 2,000 systems were installed on the roofs of mostly one-family houses. With power ratings ranging from 1 to 5 kW these decentral plants require roof surface areas between 10 and 50 m-2. On average they generate 800 kWh of electricity per kW of installed power. According to a number of studies carried out in the early 1990s the total surface area on buildings available for photovoltaics amounts to an enormous potential of 1,000 km-2, which is equivalent to an electricity generating potential of 130 TWh (100 TWh on roofs and 30 TWh on facades), or 25% of Germany`s total electricity demand. The degree to which this potential will be realised in the long term will notably depend on whether convincing architectural solutions are found for integrating photovoltaic plants in roofs and facades. [Deutsch] Der Photovoltaikmarkt waechst weltweit seit Mitte der 80er Jahre um durchschnittlich 15% und liegt heute bei einer Jahresmodulproduktion ueber 100 MW{sub p}. In Deutschland wurden alleine 1997 etwa 10.000 PV-Systeme mit einer Gesamtleistung von 10 MW{sub p} installiert. Die Marktentwicklung wurde 1990 mit dem stark subventionierten 1000-Daecher Programm angestossen, in welchem schliesslich mehr als 2000 Systeme meist auf Daechern von Einfamilienhaeusern installiert wurden. Diese dezentralen Anlagen mit Leistungen zwischen 1 und 5 kW erfordern Dachflaechen zwischen 10 und 50 m{sup 2} und erzeugen im Schnitt 800 kWh Strom pro kW installierter Leistung. Das verfuegbare Flaechenpotential von Gebaeuden wurde Anfang der 90er Jahre in einer Reihe von Studien ermittelt und stellt mit etwa 1000 km{sup 2

  5. Content Management von Leittexten mit XML Topic Maps

    Directory of Open Access Journals (Sweden)

    Johannes Busse

    2003-07-01

    Full Text Available Die Autoren definieren den Umgang mit internet- basierten Informations- und Kommunikationstechnologien als Schlüsselqualifikation für Studierende aller Fachrichtungen. Im vorliegenden Aufsatz beschreiben sie ein Projekt, das der Fachbereich Erziehungswissenschaften der Universität Heidelberg seit 2001 durchführt. Hier werden Studierende der Geistes- und Sozialwissenschaften zu "Lernberatern" ausgebildet, die als Multiplikatoren die notwendigen Kenntnisse erwerben. Die Teilnehmenden erarbeiten nach der "Leittextmethode" selbstgesteuert xml-basierte Contents. Dies setzt den Erwerb von informationstechnischen Kenntnissen voraus, der neben dem Aufbau eines (sowohl technischen als auch sozialen Netzwerks einen Schwerpunkt bildet.

  6. A Single Channel Measurement Svstem For Brain MIT

    Institute of Scientific and Technical Information of China (English)

    QINMing-xing; JIAOLi-cheng; WANGCong; LIShi-jun; DONGXiu-zhen; LUHua

    2004-01-01

    A single channel measurement system for brain MIT has been built. The system is composed of an exciting source unit, a detecting unit, a rotating and controlling unit, and imaging unit. The experiment results of single channel measurements show that the system output versus the conductivity of the objects was an approximate linear relationship when the diameter of an object was about 9cm and its conductivity was in 0.1 S/m, 0.7 S/m, 2S/m, 6S/m. The sensitivit yof the phase detector was 53 mV/degree from -10 to+10 degree.

  7. Patron-Driven Acquisition (PDA - ein Modell mit Zukunft?

    Directory of Open Access Journals (Sweden)

    Rainer Plappert

    2015-12-01

    Full Text Available Gestützt auf eine dreijährige Erfahrung mit der nutzergesteuerten Erwerbung an der UB Erlangen-Nürnberg beleuchtet der Beitrag die verschiedenen Rollen der an dieser Erwerbungsform beteiligten Akteure. Vor dem Hintergrund geänderter Geschäftsmodelle werden die zukünftigen Perspektiven der nutzergesteuerten Erwerbung in Deutschland kritisch hinterfragt. Based on a three years experience with Patron-Driven Acquisition at University library Erlangen-Nuremberg the article discusses the roles of the protagonists at this acquisition form. Regarding to modified business models the perspectives of Patron-Driven Acquision in Germany seems to be unconfident.

  8. Kaufbereitschaft für Lebensmittel mit Claims

    DEFF Research Database (Denmark)

    Aschemann-Witzel, Jessica

    2010-01-01

    Auf Lebensmitteln finden sich zunehmend nährwert- und gesundheitsbezogene Angaben ("Health Claims"). Oft sind diese nach Ansicht der Verbraucherorganisationen missverständlich und irreführend. Dem soll die neue EU-Verordnung EG 1934/2006 Abhilfe schaffen. Die Forschung zu Konsumentenverhalten und...... Claims ist jedoch noch lückenhaft. Eine Studie zeigt, dass Lebensmittel mit Claims bevorzugt gewählt und positiv beurteilt werden. Dies unterstreicht die Wichtigkeit des Einbezugs der Verbraucherperspektive bei der Gesetzgebung zu Lebensmittelinformationen....

  9. Programmierung graphischer Benutzerschnittstellen mit Tcl/Tk. - 4. Aufl.

    OpenAIRE

    Wegner, Lutz

    2009-01-01

    Das hier frei verfügbare Skript und die Sammlung an Klausuren mit Musterlösungen aus den Jahren 2005 bis 2015 geht auf die gleichnamige Vorlesung im Masterstudium Informatik an der Universität Kassel zurück. Kenntnisse in der Programmierung graphischer Oberflächen sind offensichtlich sehr nützlich, da es kaum noch Anwendungen gibt, die auf eine ansprechend gestaltete Benutzeroberfläche verzichten können. Andererseits ist die Programmierung auch heute noch sehr aufwendig. Als Ausweg empfiehlt ...

  10. Thoracic radiography and oxidative stress indices in heartworm affected dogs

    Directory of Open Access Journals (Sweden)

    P. K. Rath

    2014-09-01

    Full Text Available Aim: The aim was to study the pathomorphological changes through thoracic radiography and status of oxidative stress parameters in heartworm affected dogs in Odisha. Materials and Methods: A total of 16 dogs with clinically established diagnosis of dirofilariasis by wet blood smear and modified Knott’s test and equal numbers of dogs as control were included in this study. The present study was conducted in heartworm affected dogs to see the pathomorphological changes through thoracic radiography. Similarly, the evaluation was undertaken for observing any alterations in oxidative stress status in affected as well as non-affected, but healthy control dogs by adopting standard procedure. Results: Thoracic radiography revealed cardiac enlargement, round heart appearance suggestive of right ventricular hypertrophy, tortuous pulmonary artery and darkening of lungs. Alterations in oxidative stress indices showed a significant rise of lipid peroxidase activity, non-significant rise of superoxide dismutase and a significant although reverse trend for catalase levels in affected dogs in comparison to Dirofilaria negative control but apparently healthy dogs. Conclusions: Radiographic changes, as well as alterations in oxidative stress parameters, may not be diagnostic for heartworm infection, but useful for detecting heartworm disease, assessing severity and evaluating cardiopulmonary parenchyma changes and gives a fair idea about the degree of severity of the disease. It aids as contributing factors in disease pathogenesis.

  11. Practical contour segmentation algorithm for small animal digital radiography image

    Science.gov (United States)

    Zheng, Fang; Hui, Gong

    2008-12-01

    In this paper a practical, automated contour segmentation technique for digital radiography image is described. Digital radiography is an imaging mode based on the penetrability of x-ray. Unlike reflection imaging mode such as visible light camera, the pixel brightness represents the summation of the attenuations on the photon thoroughfare. It is not chromophotograph but gray scale picture. Contour extraction is of great importance in medical applications, especially in non-destructive inspection. Manual segmentation techniques include pixel selection, geometrical boundary selection and tracing. But it relies heavily on the experience of the operators, and is time-consuming. Some researchers try to find contours from the intensity jumping characters around them. However these characters also exist in the juncture of bone and soft tissue. The practical way is back to the primordial threshold algorithm. This research emphasizes on how to find the optimal threshold. A high resolution digital radiography system is used to provide the oriental gray scale image. A mouse is applied as the sample of this paper to show the feasibility of the algorithm.

  12. Z-petawatt driven ion beam radiography development.

    Energy Technology Data Exchange (ETDEWEB)

    Schollmeier, Marius; Geissel, Matthias; Rambo, Patrick K.; Schwarz, Jens; Sefkow, Adam B.

    2013-09-01

    Laser-driven proton radiography provides electromagnetic field mapping with high spatiotemporal resolution, and has been applied to many laser-driven High Energy Density Physics (HEDP) experiments. Our report addresses key questions about the feasibility of ion radiography at the Z-Accelerator (%E2%80%9CZ%E2%80%9D), concerning laser configuration, hardware, and radiation background. Charged particle tracking revealed that radiography at Z requires GeV scale protons, which is out of reach for existing and near-future laser systems. However, it might be possible to perform proton deflectometry to detect magnetic flux compression in the fringe field region of a magnetized liner inertial fusion experiment. Experiments with the Z-Petawatt laser to enhance proton yield and energy showed an unexpected scaling with target thickness. Full-scale, 3D radiation-hydrodynamics simulations, coupled to fully explicit and kinetic 2D particle-in-cell simulations running for over 10 ps, explain the scaling by a complex interplay of laser prepulse, preplasma, and ps-scale temporal rising edge of the laser.

  13. Assessment of Nugget Size of Spot Weld using Neutron Radiography

    Directory of Open Access Journals (Sweden)

    Triyono

    2011-08-01

    Full Text Available Resistance spot welding (RSW has been widely used for many years in the fabrication of car body structures, mainly due to the cost and time considerations. The weld quality as well as the nugget size is an issue in various manufacturing and processes due to the strong link between the weld quality and safety. It has led to the development of various destructive and non-destructive tests for spot welding such as peel testing, ultrasonic inspections, digital shearography, and infrared thermography. However, such methods cannot show spot weld nugget visually and the results are very operator’s skill dependent. The present work proposes a method to visualize the nugget size of spot welds using neutron radiography. Water, oil and various concentrations of gadolinium oxide-alcohol mixture were evaluated as a contrast media to obtain the best quality of radiography. Results show that mixture of 5 g gadolinium oxide (Gd2O3 in 25 ml alcohol produces the best contrast. It provides the possibility to visualize the shape and size of the nugget spot weld. Furthermore, it can discriminate between nugget and corona bond. The result of neutron radiography evaluation shows reasonable agreement with that of destructive test.

  14. Radiation dose estimation of patients undergoing lumbar spine radiography

    Directory of Open Access Journals (Sweden)

    Prince Kwabena Gyekye

    2013-01-01

    Full Text Available Radiation dose to organs of 100 adult patients undergoing lumbar spine (LS radiography at a University Hospital have been assessed. Free in air kerma measurement using an ionization chamber was used for the patient dosimetry. Organ and effective dose to the patients were estimated using PCXMC (version 1.5 software. The organs that recorded significant dose due to LS radiography were lungs, stomach, liver, adrenals, kidney, pancreas, spleen, galbladder, and the heart. It was observed that the stomach recorded the highest dose (48.2 ± 1.2 μGy for LS anteroposterior (AP. The spleen also recorded the highest dose (41.2 ± 0.5 μGy for LS lateral (LAT. The mean entrance surface air kerma (ESAK of LS LAT (122.2 μGy was approximately twice that of LS AP (76.3 μGy, but the effective dose for both examinations were approximately the same (LS LAT = 8.6 μSv and LS AP = 10.4 μSv. The overall stochastic health effect of radiation to patients due to LS radiography in the University Hospital is independent of the projection of the examination (AP or LAT.

  15. [Plain-film radiography in the study of spinal pain].

    Science.gov (United States)

    Ruiz Santiago, F; Guzmán Alvarez, L; Tello Moreno, M; Navarrete González, P J

    2010-01-01

    The introduction of tomographic imaging techniques, fundamentally computed tomography and magnetic resonance imaging, has led to a gradual decrease in the indications for plain-film radiography, resulting in fewer patients studied and fewer projections for each patient. Consequently, plain-film studies of the spine have received less attention and radiologists are less familiar with the typical findings in normal and pathologic conditions of the spine. Nevertheless, plain-film radiography continues to be widely used in both primary and specialized care. Thus, radiologists still need to be aware of the normal radiologic anatomy of the spine and of the radiologic manifestations of the diverse pathological processes that can affect the spinal column and that can cause pain. The aim of this article is to review the manifestations on plain-film radiography of a wide variety of diseases that can cause back pain, including congenital, traumatic, degenerative, tumor-related, inflammatory, and infectious diseases and processes. Copyright 2009 SERAM. Published by Elsevier Espana. All rights reserved.

  16. Digital radiography and advanced imaging techniques in dentistry

    Directory of Open Access Journals (Sweden)

    Burcu Keles Evlice

    2013-04-01

    Full Text Available Since the discovery of x-rays in 1895, film has been the primary medium for capturing, displaying and storing radiographic images. Digital or filmless radiography is slowly being adopted by the dental profession. Digital radiography offers a number of capabilities compared with conventional radiography, such as postprocessing, electronic archiving, concurrent access to images, and improved data distribution. Computer based applications which are used for quantitative measurements and evaluations on digital images for better user interpretation. New diagnostic imaging processes are improved connected with the technological progress of computer systems. Since the first clinical use of computed tomography (CT scans in 1972, technological development has been rapid. Dental volumetric tomography (DVT, uniquely used for dentomaxillofacial imaging came to the market owing to recent rapid developments in digital radiology technology and is becoming more popular in dental applications. Low radiation dose cone beam computed tomography (CBCT units that are commercially available at a lower cost than CT units, has performed valuable diagnostic information for dentists. [Archives Medical Review Journal 2013; 22(2.000: 230-238

  17. Management of pediatric radiation dose using Agfa computed radiography

    Energy Technology Data Exchange (ETDEWEB)

    Schaetzing, R. [Agfa Corp., Greenville, SC (United States)

    2004-10-01

    Radiation dose to patients and its management have become important considerations in modern radiographic imaging procedures, but they acquire particular significance in the imaging of children. Because of their longer life expectancy, children exposed to radiation are thought to have a significantly increased risk of radiation-related late sequelae compared to adults first exposed to radiation later in life. Therefore, current clinical thinking dictates that dose in pediatric radiography be minimized, while simultaneously ensuring sufficient diagnostic information in the image, and reducing the need for repeat exposures. Dose management obviously starts with characterization and control of the exposure technique. However, it extends farther through the imaging chain to the acquisition system, and even to the image processing techniques used to optimize acquired images for display. Further, other factors, such as quality control procedures and the ability to handle special pediatric procedures, like scoliosis exams, also come into play. The need for dose management in modern radiography systems has spawned a variety of different solutions, some of which are similar across different manufacturers, and some of which are unique. This paper covers the techniques used in Agfa Computed Radiography (CR) systems to manage dose in a pediatric environment. (orig.)

  18. Marginal Assessment of Crowns by the Aid of Parallel Radiography

    Directory of Open Access Journals (Sweden)

    Farnaz Fattahi

    2015-03-01

    Full Text Available Introduction: Marginal adaptation is the most critical item in long-term prognosis of single crowns. This study aimed to assess the marginal quality as well asthe discrepancies in marginal integrity of some PFM single crowns of posterior teeth by employing parallel radiography in Shiraz Dental School, Shiraz, Iran. Methods: In this descriptive study, parallel radiographies were taken from 200 fabricated PFM single crowns of posterior teeth after cementation and before discharging the patient. To calculate the magnification of the images, a metallic sphere with the thickness of 4 mm was placed in the direction of the crown margin on the occlusal surface. Thereafter, the horizontal and vertical space between the crown margins, the margin of preparations and also the vertical space between the crown margin and the bone crest were measured by using digital radiological software. Results: Analysis of data by descriptive statistics revealed that 75.5% and 60% of the cases had more than the acceptable space (50µm in the vertical (130±20µm and horizontal (90±15µm dimensions, respectively. Moreover, 85% of patients were found to have either horizontal or vertical gap. In 77% of cases, the margins of crowns invaded the biologic width in the mesial and 70% in distal surfaces. Conclusion: Parallel radiography can be expedient in the stage of framework try-in to yield some important information that cannot be obtained by routine clinical evaluations and may improve the treatment prognosis

  19. A New Neutron Radiography / Tomography / Imaging Station DINGO at OPAL

    Science.gov (United States)

    Garbe, U.; Randall, T.; Hughes, C.; Davidson, G.; Pangelis, S.; Kennedy, S. J.

    A new neutron radiography / tomography / imaging instrument DINGO was built to support the area of neutron imaging research (neutron radiography/tomography) at ANSTO. The instrument is designed for an international user community and for routine quality control for defense, industrial, cultural heritage and archaeology applications. In the industrial field it provides a useful tool for studying cracking and defects in steel or other metals. The instrument construction was completed at the end of June 2013 and it is currently in the hot commissioning stage. The usable neutron flux is mainly determined by the neutron source, but it depends on the instrument position and the resolution. The instrument position for DINGO is the thermal neutron beam port HB-2 in the reactor hall. The measured flux (using gold foil) for an L/D of approximately 500 at HB-2 is 5.3*107 [n/cm2s], which is in a similar range to other facilities. A special feature of DINGO is the in-pile collimator position in front of the main shutter at HB-2. The collimator offers two pinholes with a possible L/D of 500 and 1000. A secondary collimator separates the two beams by blocking one and positions another aperture for the other beam. The whole instrument operates in two different positions, one for high resolution and one for high speed. In the current configuration DINGO measured first radiography and tomography data sets on friendly user test samples.

  20. Applications of neutron radiography for the nuclear power industry

    Energy Technology Data Exchange (ETDEWEB)

    Craft, Aaron E.; Barton, John P.

    2016-11-01

    The World Conference on Neutron Radiography (WCNR) and International Topical Meeting on Neutron Radiography (ITMNR) series have been running over 35 years. The most recent event, ITMNR-8, focused on industrial applications and was the first time this series was hosted in China. In China, more than twenty new nuclear power plants are in construction and plans have been announced to increase the nuclear capacity further by a factor of three within fifteen years. There are additional prospects in many other nations. Neutron tests were vital during previous developments of materials and components for nuclear power applications, as reported in this conference series. For example a majority of the 140 papers in the Proceedings of the First WCNR are for the benefit of the nuclear power industry. Included are reviews of the diverse techniques being applied in Europe, Japan, the United States, and at many other centers. Many of those techniques are being utilized and advanced to the present time. Neutron radiography of irradiated nuclear fuel provides more comprehensive information about the internal condition of irradiated nuclear fuel than any other non-destructive technique to date. Applications include examination of nuclear waste, nuclear fuels, cladding, control elements, and other critical components. In this paper, the techniques developed and applied internationally for the nuclear power industry since the earliest years are reviewed, and the question is asked whether neutron test techniques can be of value in development of the present and future generations of nuclear power plants world-wide.

  1. Advances in computed radiography systems and their physical imaging characteristics.

    Science.gov (United States)

    Cowen, A R; Davies, A G; Kengyelics, S M

    2007-12-01

    Radiological imaging is progressing towards an all-digital future, across the spectrum of medical imaging techniques. Computed radiography (CR) has provided a ready pathway from screen film to digital radiography and a convenient entry point to PACS. This review briefly revisits the principles of modern CR systems and their physical imaging characteristics. Wide dynamic range and digital image enhancement are well-established benefits of CR, which lend themselves to improved image presentation and reduced rates of repeat exposures. However, in its original form CR offered limited scope for reducing the radiation dose per radiographic exposure, compared with screen film. Recent innovations in CR, including the use of dual-sided image readout and channelled storage phosphor have eased these concerns. For example, introduction of these technologies has improved detective quantum efficiency (DQE) by approximately 50 and 100%, respectively, compared with standard CR. As a result CR currently affords greater scope for reducing patient dose, and provides a more substantive challenge to the new solid-state, flat-panel, digital radiography detectors.

  2. Digital contrast subtraction radiography for proximal caries diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Byung Cheol; Yoon, Suk Ja [Department of Dental Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2002-06-15

    To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Thirty-six teeth with 57 proximal surfaces were radiographied using a size no.2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  3. Digital radiography in the evaluation of oesophageal motility disorders

    Energy Technology Data Exchange (ETDEWEB)

    Aly, Yehia A

    2000-07-01

    AIMS: To develop a simple technique for examination of the oesophagus by digital radiography and to assess its role in the evaluation of motility disorders of the oesophagus. MATERIALS AND METHODS: Forty-nine patients and 44 control subjects underwent manometry and digital examination of the oesophagus. The digital study consisted of two parts: firstly examination of the pharynx and cervical oesophagus using 15 ml of fluid barium in anterio-posterior (AP) and lateral views, with image acquisition of four frames/s for 2 s. Secondly, examination of the thoracic oesophagus and oesophagogastric junction using 25 ml of barium in two prone oblique and one supine AP series, with image acquisition of one frame/s for 20 s. Oesophageal transit time (OTT) was measured in each case. Abnormal or non-peristaltic contractions were described regarding their morphology, time of visualization and length. The presence or absence of hiatal hernia, reflux or any associated organic lesions was noted. RESULTS: Digital radiography diagnosed 14 cases of achalasia and 28 cases of non-specific oesophageal motility disorder (NOMD). Normal OTT was 11.95 {+-} 1.304 s. The OTT was prolonged (16 s or more) in all patients except five; four of these were cases of NOMD. Abnormal contractions were classified into circular and longitudinal types. The circular non-obliterating type was commoner. Achalasia was diagnosed in all cases, as failure of relaxation of the inferior oesophageal sphincter was always present and easily depicted by digital radiography. Abnormal contractions in the body of the oesophagus were elicited in 57% of cases of achalasia. The sensitivity of digital radiography in detecting oesophageal motility disorders was 85.7% based on the presence of abnormal contractions and 91.6% by eliciting a prolonged OTT. CONCLUSIONS: Examination of the oesophagus by digital radiography is simple, non-invasive, reproducible, rapid and without discomfort to patients. It allows the diagnosis of

  4. Helicobacter sp. MIT 01-6451 infection during fetal and neonatal life in laboratory mice.

    Science.gov (United States)

    Yamanaka, Hitoki; Nakanishi, Tai; Takagi, Toshikazu; Ohsawa, Makiko; Kubo, Noriaki; Yamamoto, Naoto; Takemoto, Takahira; Ohsawa, Kazutaka

    2015-01-01

    Helicobacter sp. MIT 01-6451 has been detected in SPF mice kept in Japan. To characterize strain MIT 01-6451, its infection route during fetal and neonatal life and effects on pregnancy were investigated using immunocompetent and immunodeficient mouse strains (BALB/c, C57BL/6, and SCID). MIT 01-6451 was detected in the uterus, vagina, and mammary glands of 50% of infected SCID mice, whereas these tissues were all negative in immunocompetent mice. No fetal infections with MIT 01-6451 were detected at 16-18 days after pregnancy in any mouse strain. In newborn mice, MIT 01-6451 was detected in intestinal tissue of C57BL/6 and SCID mice at 9-11 days after birth, but not in BALB/c mice. The IgA and IgG titers to MIT 01-6451 in sera of C57BL/6 female mice were significantly lower than those of BALB/c mice. Although no significant differences in the number of newborns per litter were observed between MIT 01-6451-infected and MIT 01-6451-free dams, the birth rate was lower in infected SCID mice than in control SCID mice. The present results indicated that MIT 01-6451 infects newborn mice after birth rather than by vertical transmission to the fetus via the placenta and that MIT 01-6451 infection shows opportunistically negative effects on the birth rate. In addition, the maternal immune response may affect infection of newborn mice with MIT 01-6451 through breast milk.

  5. Quark Orbital Angular Momentum in the MIT Bag Model

    CERN Document Server

    Courtoy, A

    2016-01-01

    We present the results for the Generalized Transverse Momentum Distribution related to quark Orbital Angular Momentum, {\\it i.e.} $F_{14}$, in the MIT bag model. This model has been modified to include the Peierls--Yoccoz projection to restore translational invariance. Such a modification allows to fulfill more satisfactorily basic sum rules, that would otherwise be less elegantly carried out with the original version. Using the same model, we have calculated the twist-$3$ GPD that corresponds to Orbital Angular Momentum \\`a la Ji, through the Penttinen--Polyakov--Shuvaev--Strikman sum rule. Recently, a new relation between the two definitions of the quark Orbital Angular Momentum at the density level has been proposed, which we illustrate here within the model. The sum rule is fulfilled. Still within the framework of the MIT bag model, we analyze the Wandzura--Wilczek expression for the GPD of interest. The genuine quark-gluon contribution is evaluated directly thanks to the equation of motion of the bag, wh...

  6. Material Identification Technology (MIT) concept technical feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Jones, J.L.; Harker, Y.D.; Yoon, W.Y.; Johnson, L.O.

    1993-09-01

    The Idaho National Engineering Laboratory (INEL) has initiated the design and development of a novel pulsed accelerator-based, active interrogation concept. The proposed concept, referred to as the Material Identification Technology (MIT), enables rapid (between accelerator pulses), non-destructive, elemental composition analysis of both nuclear and non-nuclear materials. Applications of this technique include material monitoring in support of counter-proliferation activities, such as export controls (at domestic and international inspection locations), SNM controls, nuclear weapon dismantlement, and chemical weapon verification. Material Identification Technology combines a pulsed, X-ray source (an electron accelerator) and a gamma detection system. The accelerator must maximize neutron production (pulse width, beam current, beam energy, and repetition rate) and minimize photon dose to the object. Current available accelerator technology can meet these requirements. The detection system must include detectors which provide adequate gamma energy resolution capability, rapid recovery after the initial X-ray interrogation pulse, and multiple single gamma event detection between accelerator pulses. Further research is required to develop the detection system. This report provides the initial feasibility assessment of the MIT concept.

  7. MIT Lincoln Laboratory: Physics and Technology in the National Interest

    Science.gov (United States)

    Ralston, Richard

    2001-03-01

    This year, MIT is celebrating the 50th anniversary of the founding of Lincoln Laboratory, which was formed at the request of the DoD with the initial goal of developing a national air defense system. In its 50 years, the Laboratory staff have made significant contributions in diverse areas including radar imaging, satellite communications, digital signal processing, computer science, semiconductor materials and solid state physics. The Laboratory has been true to its mission statement, which places strong emphasis on the application of advanced electronics to R&D in the national interest. Much of the technology is transitioned to U.S. industry for both government and commercial use. Annually more than 500 publications and meeting speeches are given, and cooperative developments with industry have targeted technology transitions ranging from next-generation photolithographic tools to microchip lasers. The Laboratory staff have been granted over 400 patents, and license to this intellectual property is at the core of many of the over 70 spin-off companies. MIT employs 2,300 people at Lincoln, including 1,200 professionals with degrees in physics, math, computer science, materials science and the engineering disciplines. Two-fifths of the professional staff are at the doctoral level; over two-thirds hold advanced degrees. This presentation will describe recent examples of research challenges for physicists in a multidisciplinary project-oriented environment.

  8. Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Wan; Lee, Byung Do [Wonkwang University College of Medicine, Iksan (Korea, Republic of)

    2003-03-15

    The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p>0.05). These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  9. Diagnostic value of pelvic radiography in the initial trauma series in blunt trauma

    Energy Technology Data Exchange (ETDEWEB)

    Their, Micael E.A.; Bensch, Frank V.; Koskinen, Seppo K. [Toeoeloe Trauma Center, Department of Radiology, Helsinki University Central Hospital, Helsinki (Finland); Handolin, Lauri [Toeoeloe Trauma Center, Department of Orthopaedics and Traumatology, Helsinki (Finland); Kiuru, Martti J. [Toeoeloe Trauma Center, Department of Radiology, Helsinki University Central Hospital, Helsinki (Finland); Research Institut of Military Medicine, Helsinki (Finland)

    2005-08-01

    The purpose of the study was to evaluate the diagnostic value of pelvic radiography in the initial trauma series when compared to multidetector CT (MDCT) findings in serious blunt trauma. Inclusion criteria were blunt trauma and pelvic radiography in the initial trauma series, followed by a whole-body MDCT. A total of 1386 patients (874 male, 512 female, age 16-91 years, mean 41 years) met the inclusion criteria. Imaging studies were evaluated retrospectively by anatomical region and classified, when possible, using the Tile classification. Based on MDCT, a total of 629 injuries occurred in 226 (16%) of these 1386 patients. Radiography depicted 405 fractures in these 226 patients, giving an overall sensitivity of 55%. In 24 patients (11%) radiography was false-negatively normal. The sensitivity of radiography was mainly good in the anteroinferior parts of the pelvis, fair in the acetabulum and ileum, and poor in the posterior ring. By MDCT 141 (62%) patients were classified using the Tile classification and by radiography 133 patients (59%) were classified. MDCT and radiography showed the same type of pelvic injury in 72 patients (59%) and the subtype in 17 patients (14%). In 48 patients (40%) the pelvis was shown to be stable by radiography but unstable by MDCT. In conclusion, the sensitivity of pelvic radiography is low, and it is not reliable for determining if the pelvic injury is stable or not. (orig.)

  10. Value of postmortem thoracic CT over radiography in imaging of pediatric rib fractures

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Terence S.; Babyn, Paul S. [The Hospital for Sick Children, Department of Diagnostic Imaging, Toronto (Canada); Reyes, Jeanette A.; Chiasson, David A. [The Hospital for Sick Children, Department of Paediatric Laboratory Medicine, Toronto (Canada); Moineddin, Rahim [University of Toronto, Department of Family and Community Medicine, Toronto (Canada); Berdon, Walter E. [Columbia Presbyterian Medical Center, Babies Hospital, Department of Radiology, New York, NY (United States)

    2011-06-15

    Studies have reported that thoracic CT may provide greater sensitivity compared with radiography in detection of pediatric rib fractures and fracture healing. The additional sensitivity afforded by thoracic CT may have medicolegal implications where abuse is suspected. To determine the additional value of postmortem thoracic CT compared with radiography in detecting pediatric rib fractures, and fracture healing, using autopsy findings as a gold standard. We retrospectively reviewed 56 coroner's cases with postmortem radiography and CT thoracic survey. All studies underwent primary interpretation by one or two radiologists. The study radiologist independently reviewed all images from 13 patients with positive findings on radiography, CT or autopsy. Sensitivity and specificity between observers and imaging modalities were compared. Primary interpretation: Fractures were recognized on radiography in 5/12 patients who had fractures found at autopsy, and on CT in 8/12 patients. In total, 29% (24/83) of fractures were reported on radiography, and 51% (52/101) of fractures were reported on CT. Study radiologist: Fractures were recognized on radiography in 7/12 patients who had fractures found at autopsy, and on CT in 11/12 patients. In total, 46% (38/83) of fractures were reported on radiography, and 85% (86/101) of fractures were reported on CT. Postmortem thoracic CT provides greater sensitivity than radiography in detecting pediatric rib fractures, most notably in anterior and posterior fractures. However, the degree of improvement in sensitivity provided by CT might depend on observer experience. (orig.)

  11. Electronic imaging system for neutron radiography at a low power research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, F.J.O., E-mail: fferreira@ien.gov.b [Instituto de Engenharia Nuclear, Comissao Nacional de Energia Nuclear, Caixa Postal 68550, CEP 21945-970, Rio de Janeiro (Brazil); Silva, A.X.; Crispim, V.R. [PEN/COPPE-DNC/POLI CT, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970 Rio de Janeiro (Brazil)

    2010-08-15

    This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.

  12. Treatment planning with functional MRI; Strahlentherapieplanung mit der funktionellen MRT

    Energy Technology Data Exchange (ETDEWEB)

    Georg, P. [EBG MedAustron GmbH, Wiener Neustadt (Austria); Medizinische Universitaet Wien, Christian Doppler Labor fuer die Medizinische Strahlenforschung, Wien (Austria); Andrzejewski, P.; Georg, D. [Medizinische Universitaet Wien, Christian Doppler Labor fuer die Medizinische Strahlenforschung, Wien (Austria); Medizinische Universitaet Wien, Abteilung fuer medizinische Strahlenphysik, Univ. Klinik fuer Strahlentherapie, Wien (Austria); Pinker, K. [Medizinische Universitaet Wien, Christian Doppler Labor fuer die Medizinische Strahlenforschung, Wien (Austria); Medizinische Universitaet Wien, Abteilung fuer molekulare Bildgebung, Univ. Klinik fuer Radiologie und Nuklearmedizin, Wien (Austria)

    2015-12-15

    The aim of magnetic resonance imaging (MRI) guided radiotherapy is high precision in treatment delivery. With new developments it is possible to focus the high dose irradiation on the tumor while sparing the surrounding tissue. The achievements in precision of the treatment planning and delivery warrant equally precise tumor definition. In conventional radiation therapy it is necessary to carry out a planning computed tomography (CT). For many tumors there is also need for an additional morphological MRI because of more accurate tumor definition. In standard radiotherapy the tumor volume is irradiated with a homogeneous dose. The aim of functional multiparametric MRI is to visualize and quantify biological, physiological and pathological processes at the cellular and molecular levels. Based on this information it is possible to elucidate tumor biology and identify subvolumes of more aggressive behavior. They are often radiotherapy-resistant, leading to tumor recurrence thus requiring further dose escalation. The concept of inhomogeneous tumor irradiation according to its biological behavior is called dose painting. Dose painting is technically feasible. The expected clinical benefit is motivated by selective treatment adaptations based on biological tumor characteristics. Tumors show variable response to therapy underlining the need for individual treatment plans. This approach may lead not only to higher local control but also to better sparing of normal surrounding tissue. With the clinical implementation of dose painting, improvements in the therapeutic outcome can be expected. Due to the existing technical challenges, extensive collaboration between radiation oncologists, radiologists, medical physicists and radiation biologists is needed. (orig.) [German] Die Strahlentherapieplanung mit der funktionellen Magnetresonanztomographie (fMRT) zielt auf eine Hochpraezisionsradiotherapie ab. Mit den modernen Technologien ist es moeglich, die Strahlentherapie nahezu

  13. Messung der Vorwärts-Rückwärts-Ladungsassymetrie von b-Quarks bei Energien nahe der Z0-Resonanz. Untersuchung von Ereignissen mit initialem b-Quark unter Verwendung der Jetladungstechnik mit dem DELPHI Detektor

    CERN Document Server

    Schwering, Britta

    Messung der Vorwärts-Rückwärts-Ladungsassymetrie von b-Quarks bei Energien nahe der Z0-Resonanz. Untersuchung von Ereignissen mit initialem b-Quark unter Verwendung der Jetladungstechnik mit dem DELPHI Detektor

  14. Scratch that: MIT's Mitchel Resnick Says Kids Should Do It for Themselves

    Science.gov (United States)

    Traylor, Scott

    2008-01-01

    Mitchel Resnick is a researcher, inventor, and professor at MIT's Media Laboratory in Cambridge, MA, and the founder of the Lifelong Kindergarten Group at MIT. He is the lead innovator behind many cutting-edge learning technologies and projects for children, including the Computer Clubhouse, PicoCrickets, and the wildly successful consumer…

  15. Rapid-Prototyping hydraulisch härtender Calcium- und Magnesiumphosphatzemente mit lokaler Wirkstoffmodifikation

    OpenAIRE

    2012-01-01

    Ziel dieser Arbeit war die Herstellung individuell formbarer Strukturen mittels des 3D-Pulverdrucks auf Basis von bei Raumtemperatur hydraulisch abbindenden Knochenzementpulvern. Neben der Entwicklung neuartiger Zementformulierungen auf Basis von Magnesiumphosphaten war vor allem die gleichzeitige Ausstattung der Werkstoffe mit temperaturlabilen und bioaktiven Verbindungen ein wichtiger Entwicklungsschritt. Die Lokalisation der Wirkstoffe korreliert dabei mit entsprechenden Farbinformationen ...

  16. MIT(1), a black mamba toxin with a new and highly potent activity on intestinal contraction.

    Science.gov (United States)

    Schweitz, H; Pacaud, P; Diochot, S; Moinier, D; Lazdunski, M

    1999-11-19

    Mamba intestinal toxin (MIT(1)) isolated from Dendroaspis polylepis venom is a 81 amino acid polypeptide cross-linked by five disulphide bridges. MIT(1) has a very potent action on guinea-pig intestinal contractility. MIT(1) (1 nM) potently contracts longitudinal ileal muscle and distal colon, and this contraction is equivalent to that of 40 mM K(+). Conversely MIT(1) relaxes proximal colon again as potently as 40 mM K(+). The MIT(1)-induced effects are antagonised by tetrodotoxin (1 microM) in proximal and distal colon but not in longitudinal ileum. The MIT(1)-induced relaxation of the proximal colon is reversibly inhibited by the NO synthase inhibitor L-NAME (200 microM). (125)I-labelled MIT(1) binds with a very high affinity to both ileum and brain membranes (K(d)=1.3 pM and 0.9 pM, and B(max)=30 fmol/mg and 26 fmol/mg, respectively). MIT(1) is a very highly selective toxin for a receptor present both in the CNS and in the smooth muscle and which might be an as yet unidentified K(+) channel.

  17. MIT domain of Vps4 is a Ca2+-dependent phosphoinositide-binding domain.

    Science.gov (United States)

    Iwaya, Naoko; Takasu, Hirotoshi; Goda, Natsuko; Shirakawa, Masahiro; Tanaka, Toshiki; Hamada, Daizo; Hiroaki, Hidekazu

    2013-05-01

    The microtubule interacting and trafficking (MIT) domain is a small protein module that is conserved in proteins of diverged function, such as Vps4, spastin and sorting nexin 15 (SNX15). The molecular function of the MIT domain is protein-protein interaction, in which the domain recognizes peptides containing MIT-interacting motifs. Recently, we identified an evolutionarily related domain, 'variant' MIT domain at the N-terminal region of the microtubule severing enzyme katanin p60. We found that the domain was responsible for binding to microtubules and Ca(2+). Here, we have examined whether the authentic MIT domains also bind Ca(2+). We found that the loop between the first and second α-helices of the MIT domain binds a Ca(2+) ion. Furthermore, the MIT domains derived from Vps4b and SNX15a showed phosphoinositide-binding activities in a Ca(2+)-dependent manner. We propose that the MIT domain is a novel membrane-associating domain involved in endosomal trafficking.

  18. Assessing International Product Design and Development Graduate Courses: The MIT-Portugal Program

    Science.gov (United States)

    Dori, Yehudit Judy; Silva, Arlindo

    2010-01-01

    The Product Design and Development (PDD) course is part of the graduate curriculum in the Engineering Design and Advanced Manufacturing (EDAM) study in the MIT-Portugal Program. The research participants included about 110 students from MIT, EDAM, and two universities in Portugal, Instituto Superior Técnico-Universidade Técnica de Lisboa (IST) and…

  19. Scratch that: MIT's Mitchel Resnick Says Kids Should Do It for Themselves

    Science.gov (United States)

    Traylor, Scott

    2008-01-01

    Mitchel Resnick is a researcher, inventor, and professor at MIT's Media Laboratory in Cambridge, MA, and the founder of the Lifelong Kindergarten Group at MIT. He is the lead innovator behind many cutting-edge learning technologies and projects for children, including the Computer Clubhouse, PicoCrickets, and the wildly successful consumer…

  20. Immunregulation bei aggressiver Parodontitis im Vergleich mit moderater chronischer Parodontitis und gesundem Parodontium

    OpenAIRE

    Schmidt, Jana

    2013-01-01

    Es ist davon auszugehen, dass Fehlfunktionen im Immunsystem mit der Ausprä-gung des Krankheitsbildes der aggressiven Parodontitis im Zusammenhang ste-hen. In dieser Arbeit sollen anhand klinischer, immunologischer und mikrobiologischer Untersuchungen ein immunologisches Risikoprofil bei Patienten mit aggressiver Parodontitis erschlossen, gegebenenfalls Unterschiede zur moderaten chronischen Parodontitis beleuchtet und explorativ Zusammenhänge zwischen immunologischen und mikrobiologischen Bef...

  1. Child Care is Everybody's Baby: A Comprehensive Report of Child Care Services, Past, Present, and Future at M.I.T. Final Child Care Proposals as Accepted by M.I.T.

    Science.gov (United States)

    Swartz, Marilyn S.

    The report on child care services at M.I.T. explores the following areas: (1) Planning Issues: Why Should M.I.T. Be Involved in Child Care?--educational concerns, services, benefits and costs, priorities, resource allocation; (2) Background for Planning; Current Institute Child Care Programs--a concise history, M.I.T. summer day camp, the…

  2. Acute paediatric ankle trauma: MRI versus plain radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lohman, M. [Helsinki Univ. Central Hospital (Finland). Dept. of Radiology; Radiological Dept., Helsinki University Central Hospital (Finland); Kivisaari, A.; Kivisaari, L. [Helsinki Univ. Central Hospital (Finland). Dept. of Radiology; Kallio, P.; Puntila, J. [Dept. of Paediatric Surgery, Hospital for Children and Adolescents, Helsinki Univ. Central Hospital, Helsinki (Finland); Vehmas, T. [Finnish Institute of Occupational Health, Helsinki (Finland)

    2001-09-01

    Objective: To evaluate the diagnosis of acute physeal ankle fractures on plain radiographs using MRI as the gold standard. Methods: Sixty consecutive children, 29 with a clinical diagnosis of lateral ligament injury and 31 with physeal ankle fractures, were examined using both radiographs and MRI in the acute period. The imaging data were reviewed by three ''masked'' radiologists. The fracture diagnosis and Slater-Harris classification of radiographs were compared with findings on MRI. Results: Plain radiography produced five of 28 (18%) false negative and 12 of 92 (13%) false positive fracture diagnoses compared with MRI. Six of the 12 false positive fractures were due to a misclassification of lateral ligament disruption as SH1 fractures. Altogether a difference was found in 21% of cases in either the diagnosis or the classification of the fractures according to Salter- Harris. All bone bruises in the distal tibia and fibula and 64% of bone bruises in the talus were seen in association with lateral ligament injuries. Talar bone bruises in association with fractures occurred on the same side as the malleolar fracture; talar bone bruises in association with lateral ligament disruption were seen in different locations. The errors identified on radiographs by MRI did not affect the management of the injury. Conclusions: The incidence of false negative ankle fractures in plain radiographs was small and no complex ankle fractures were missed on radiographs. The total extent of complex fractures was, however, not always obvious on radiographs. In an unselected series of relatively mild ankle injuries, we were unable to show a single case where the treatment or prognosis based on plain radiography should have been significantly altered after having done a routine MRI examination. Plain radiography is still the diagnostic cornerstone of paediatric ankle injuries. (orig.)

  3. Spectroscopic neutron radiography for a cargo scanning system

    Energy Technology Data Exchange (ETDEWEB)

    Rahon, Jill [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States); Danagoulian, Areg, E-mail: aregjan@mit.edu [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States); MacDonald, Thomas D. [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States); Hartwig, Zachary S. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States); Lanza, Richard C. [Department of Nuclear Science and Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave, Cambridge, MA 02139 (United States)

    2016-06-01

    Detection of cross-border smuggling of illicit materials and contraband is a challenge that requires rapid, low-dose, and efficient radiographic technology. The work we describe here is derived from a technique which uses monoenergetic gamma rays from low energy nuclear reactions, such as {sup 11}B(d,nγ){sup 12}C, to perform radiographic analysis of shipping containers. Transmission ratios of multiple monoenergetic gamma lines resulting from several gamma producing nuclear reactions can be employed to detect materials of high atomic number (Z), the details of which will be described in a separate paper. Inherent in this particular nuclear reaction is the production of fast neutrons which could enable neutron radiography and further characterization of the effective-Z of the cargo, especially within the range of lower Z. Previous research efforts focused on the use of total neutron counts in combination with X-ray radiography to characterize the hydrogenous content of the cargo. We present a technique of performing transmitted neutron spectral analysis to reconstruct the effective Z and potentially the density of the cargo. This is made possible by the large differences in the energy dependence of neutron scattering cross-sections between hydrogenous materials and those of higher Z. These dependencies result in harder transmission spectra for hydrogenous cargoes than those of non-hydrogenous cargoes. Such observed differences can then be used to classify the cargo based on its hydrogenous content. The studies presented in this paper demonstrate that such techniques are feasible and can provide a contribution to cargo security, especially when used in concert with gamma radiography.

  4. Spectroscopic neutron radiography for a cargo scanning system

    Science.gov (United States)

    Rahon, Jill; Danagoulian, Areg; MacDonald, Thomas D.; Hartwig, Zachary S.; Lanza, Richard C.

    2016-06-01

    Detection of cross-border smuggling of illicit materials and contraband is a challenge that requires rapid, low-dose, and efficient radiographic technology. The work we describe here is derived from a technique which uses monoenergetic gamma rays from low energy nuclear reactions, such as 11B(d,nγ)12C, to perform radiographic analysis of shipping containers. Transmission ratios of multiple monoenergetic gamma lines resulting from several gamma producing nuclear reactions can be employed to detect materials of high atomic number (Z), the details of which will be described in a separate paper. Inherent in this particular nuclear reaction is the production of fast neutrons which could enable neutron radiography and further characterization of the effective-Z of the cargo, especially within the range of lower Z. Previous research efforts focused on the use of total neutron counts in combination with X-ray radiography to characterize the hydrogenous content of the cargo. We present a technique of performing transmitted neutron spectral analysis to reconstruct the effective Z and potentially the density of the cargo. This is made possible by the large differences in the energy dependence of neutron scattering cross-sections between hydrogenous materials and those of higher Z. These dependencies result in harder transmission spectra for hydrogenous cargoes than those of non-hydrogenous cargoes. Such observed differences can then be used to classify the cargo based on its hydrogenous content. The studies presented in this paper demonstrate that such techniques are feasible and can provide a contribution to cargo security, especially when used in concert with gamma radiography.

  5. Characterization of non-tuberculosis mycobacteria by neutron radiography.

    Science.gov (United States)

    da Silva, Jaqueline M; Crispim, Verginia Reis; da Silva, Marlei Gomes; Furtado, Vanessa Rodrigues; Duarte, Rafael Da Silva

    2013-07-01

    The genus Mycobacterium shares many characteristics with Corynebacterium and Actinomyces genera, among which the genomic guanine plus cytosine content and the production of long branched-chain fatty acids, known as mycolic acids are enhanced. Growth rate and optimal temperature of mycobacteria are variable. The genus comprises more than 140 known species; however Mycobacterium fortuitum, a fast growing nontuberculous mycobacterium, is clinically significant, because it has been associated to several lesions following surgery procedures such as liposuction, silicone breast and pacemaker implants, exposure to prosthetic materials besides sporadic lesions in the skin, soft tissues and rarely lungs. The objective of the present study is to reduce the time necessary for M. fortuitum characterization based on its morphology and the use of the neutron radiography technique substituting the classical biochemical assays. We also aim to confirm the utility of dendrimers as boron carriers. The samples were sterilized through conventional protocols using 10% formaldehyde. In the incubation process, two solutions with different molar ratios (10:1 and 20:1) of sodium borate and PAMAM G4 dendrimer and also pure sodium borate were used. After doping and sterilization procedures, the samples were deposited on CR-39 sheets, irradiated with a 4.6×10(5) n/cm(2)s thermal neutron flux for 30 min, from the J-9 irradiation channel of the Argonauta IEN/CNEN reactor. The images registered in the CR-39 were visualized in a Nikon E400 optical transmission microscope and captured by a Nikon Coolpix 995 digital camera. Developing the nuclear tracks registered in the CR-39 allowed a 1000× enlargement of mycobacterium images, facilitating their characterization, the use of more sophisticated equipment not being necessary. The use of neutron radiography technique reduced the time necessary for characterization. Doping with PAMAM dendrimer improved the visualization of NTM in neutron radiography

  6. [R]MIT Research Centre at Delft University of Technology: A Bridge between Research, Education, Society and Profession

    Science.gov (United States)

    Zijlstra, Hielkje

    2009-01-01

    In 2006, we launched the [R]MIT Research Centre (Modification, Intervention Transformation) at the Faculty of Architecture at Delft University of Technology. [R]MIT was founded to respond to the need for an integrated, multi-disciplinary approach to the transformation of the built environment. [R]MIT aims to bring momentum to the renewal of…

  7. Operating experience with innovative environmental technologies; Betriebserfahrungen mit innovativen Umwelttechnologien

    Energy Technology Data Exchange (ETDEWEB)

    Spindler, H.; Bauermeister, U.; Kliche, H.; Seiffarth, K. (comps.)

    2000-03-01

    The MUT '99 (Merseburger Umwelt-Tag) discussed modern processes, technologies and plants for treatment and utilisation of waste. The conference was attended by industrial organisations and scientific institutions. [German] Der 9. Merseburger Umwelt-Tag MUT '99 steht unter dem Motto 'Betriebserfahrungen mit innovativen Umwelttechnologien - Moderne wirtschaftliche Verfahren, Technologien und Anlagen zur Behandlung/Verwertung nichtvermeidbaren Abfalls', wobei der Begriff 'Abfall' sich letztlich auf alle Umweltmedien bezieht. Entsprechend dem Motto dieser Tagung stellen Unternehmen, Betriebe und wissenschaftliche Einrichtungen ihre Erfahrungen auf dem Gebiet der Umwelttechnologien vor, um Entwicklungen auf diesem Gebiet einer breiten Diskussion zu eroeffnen. Dabei soll es insbesondere um die Behandlung nicht vermeidbarer Abfaelle und Abwaesser gehen. (orig.)

  8. A novel type epithermal neutron radiography detecting and imaging system

    CERN Document Server

    Balasko, M; Svab, E; Eoerdoegh, I

    1999-01-01

    The transfer technique is widely used for epithermal neutron radiography (ENR) for making images upon the object to be investigated. We propose to use instead of the photosensitive film a gamma sensitive scintillation screen (NaCe single crystal), that is monitored by a computer controlled low light level TV camera. The exposure time has been reduced to a duration of only a short fraction of that needed for the conventional transfer process. The presented ENR images consist of electronic signals that are handled by an advanced image processing and analyzing program, the Iman 1.4 version, using a task oriented video grabber.

  9. Fail-safe neutron shutter used for thermal neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Sachs, R.D.; Morris, R.A.

    1976-11-01

    A fail-safe, reliable, easy-to-use neutron shutter was designed, built, and put into operation at the Omega West Reactor, Los Alamos Scientific Laboratory. The neutron shutter will be used primarily to perform thermal neutron radiography, but is also available for a highly collimated source of thermal neutrons (neutron flux = 3.876 x 10/sup 6/ (neutrons)/(cm/sup 2/.s)). Neutron collimator sizes of either 10.16 by 10.16 cm or 10.16 by 30.48 cm are available.

  10. Saferad industrial radiography system; Sistema Saferad de radiografia industrial

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Wallace Aparecido de [NDT do Brasil Ltda., Sao Paulo, SP (Brazil)

    2005-07-01

    The Saferad industrial radiography system is a system for execution of radiographic tests that provide small rays of insulation compared to conventional techniques. The system consists of a special irradiator that can be operated in three modes of exposure: Projection, Directional, and Panoramic with a set of collimators for different diameters of tubes, which collimate the radiation only to the area of the film. The radioisotope used is Selenium-75. Complements the system the shielding GammaBlok, polymer based on cadmium, flexible, non-toxic, and presented in various dimensions and shapes. It should involve the radiographic arrangement to shield the radiation after it goes through the film and the scattered radiation.

  11. Upgrading of neutron radiography/tomography facility at research reactor

    Energy Technology Data Exchange (ETDEWEB)

    Abd El Bar, Waleed; Mongy, Tarek [Atomic Energy Authority, Cairo (Egypt). ETRR-2; Kardjilov, Nikolay [Helmholtz Zentrum Berlin (HZB) for Materials and Energy, Berlin (Germany)

    2014-03-15

    A state-of-the-art neutron tomography imaging system was set up at the neutron radiography beam tube at the Egypt Second Research Reactor (ETRR-2) and was successfully commissioned in 2013. This study presents a set of tomographic experiments that demonstrate a high quality tomographic image formation. A computer technique for data processing and 3D image reconstruction was used to see inside a copy module of an ancient clay article provided by the International Atomic Energy Agency (IAEA). The technique was also able to uncover tomographic imaging details of a mummified fish and provided a high resolution tomographic image of a defective fire valve. (orig.)

  12. Detectability of simulated vessels by computed radiography and digital fluorography

    Energy Technology Data Exchange (ETDEWEB)

    Misumi, Wataru; Yoshioka, Senya; Korogi, Yukunori; Takahashi, Mutsumasa (Kumamoto Univ. (Japan). School of Medicine); Higashida, Yoshiharu

    1990-05-01

    Phantom studies were carried out to determine the ability to digital subtraction angiography (DSA), using either Fuji computed radiography (CR) or digital fluorography (DF) system, to detect the simulated vessels. The assessment of detectability was based on observer performance techniques. DFDSA was superior to CRDSA. Detectability of CRDSA was influenced by the incident X-ray exposures. Even though it was improved by contrast enhancement, the magnitude of improvement was dependent upon the incident X-ray exposures and vessel size. (N.K.).

  13. Panoramic radiography for temporomandibular joint arthrography: a description of arthropanoramograms.

    Science.gov (United States)

    Abramovitch, K; Langlais, R P; Dolwick, M F

    1989-06-01

    TMJ arthrograms done with panoramic radiography, i.e., arthropanoramography, can demonstrate intracapsular disk displacement and perforation pathoses. These views are very practical for inferior synovial cavity arthrograms performed in the dental operatory since panoramic radiographic machines have become common in modern dental practices. Specific advantages of arthropanoramography include the decreased financial cost and decreased radiation exposure to the patient. Arthropanoramography does not replace tomography or videofluoroscopy in TMJ arthrography. It is, however, described as a simple alternative to the more conventional forms of arthrography.

  14. High efficiency gaseous tracking detector for cosmic muon radiography

    CERN Document Server

    Varga, Dezső; Hamar, Gergő; Oláh, László

    2016-01-01

    A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized for the application of muon radiography. The main features are high (>99.5%) and uniform detection efficiency, 9 mm FWHM position resolution, filling gas consumption below 2 liters per hour for the non toxic, non flammable argon and carbon dioxide mixture. These parameters, along with the simplicity of the construction and the tolerance for mechanical effects, make the detectors to be a viable option for a large area muography observation system.

  15. Computed radiography simulation using the Monte Carlo code MCNPX

    Energy Technology Data Exchange (ETDEWEB)

    Correa, S.C.A. [Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil); Centro Universitario Estadual da Zona Oeste (CCMAT)/UEZO, Av. Manuel Caldeira de Alvarenga, 1203, Campo Grande, 23070-200, Rio de Janeiro, RJ (Brazil); Souza, E.M. [Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil); Silva, A.X., E-mail: ademir@con.ufrj.b [PEN/COPPE-DNC/Poli CT, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil); Cassiano, D.H. [Instituto de Radioprotecao e Dosimetria/CNEN Av. Salvador Allende, s/n, Recreio, 22780-160, Rio de Janeiro, RJ (Brazil); Lopes, R.T. [Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, Ilha do Fundao, Caixa Postal 68509, 21945-970, Rio de Janeiro, RJ (Brazil)

    2010-09-15

    Simulating X-ray images has been of great interest in recent years as it makes possible an analysis of how X-ray images are affected owing to relevant operating parameters. In this paper, a procedure for simulating computed radiographic images using the Monte Carlo code MCNPX is proposed. The sensitivity curve of the BaFBr image plate detector as well as the characteristic noise of a 16-bit computed radiography system were considered during the methodology's development. The results obtained confirm that the proposed procedure for simulating computed radiographic images is satisfactory, as it allows obtaining results comparable with experimental data.

  16. BBU design of linear induction accelerator cells for radiography application

    Energy Technology Data Exchange (ETDEWEB)

    Shang, C.C.; Chen, Y.J.; Gaporaso, G.J.; Houck, T.L.; Molau, N.E.; Focklen, J.; Gregory, S.

    1997-05-06

    There is an ongoing effort to develop accelerating modules for high-current electron accelerators for advanced radiography application. Accelerating modules with low beam-cavity coupling impedances along with gap designs with acceptable field stresses comprise a set of fundamental design criteria. We examine improved cell designs which have been developed for accelerator application in several radiographic operating regimes. We evaluate interaction impedances, analyze the effects of beam structure coupling on beam dynamics (beam break-up instability and corkscrew motion). We also provide estimates of coupling through interesting new high-gradient insulators and evaluate their potential future application in induction cells.

  17. Pathophysiologie des Kollagenstoffwechsels bei Patienten mit Induratio penis plastica (IPP

    Directory of Open Access Journals (Sweden)

    Lahme S

    2000-01-01

    Full Text Available Die Pathogenese der IPP ist bis heute nicht geklärt. Histopathologische Untersuchungen zeigen, daß der Kollagenstoffwechsel eine Rolle spielt. Dies veranlaßte uns zur genauen Analyse der Kollagenstoffwechselparameter bei IPP. Bei 11 Patienten mit IPP und 11 Kontrollpersonen wurden Kollagenstoffwechselparameter (Prokollagen III [PIIIP], PMN-Elastase [PMN-E], Fibronektin [FN], Fibronektinrezeptor [FN-R] und alpha1-Proteinase-Inhibitor [alpha1-PI] im cavernösen und peripheren Blut bestimmt. PMN-E, PIIIP, FN und FN-R waren in den beiden Untersuchungsgruppen nicht unterschiedlich. Die peripher venösen unterschieden sich nicht von den cavernösen Blutproben. Sowohl im peripher venös (158,55 mg/dl als auch im cavernös entnommenen Blut (168,29 mg/dl war die Konzentration des a1-PI signifikant niedriger als in der Kontrollgruppe (214,82 mg/dl. An einem zweiten Kollektiv von 23 Patienten wurden Analysen des Phänotyps für alpha1-PI im Hinblick auf das Vorliegen von genetisch determinierten Mangelallelen vorgenommen. Hier zeigte sich kein signifikanter Unterschied zu einem Kontrollkollektiv von 19 gesunden Probanden. Die alpha1-PI Erniedrigung der IPP-Patienten ist signifikant und liegt unterhalb des Normalwertbereichs für die gesunde Population. Ein Mangel an alpha1-PI kann zur Aktivitätserhöhung der Proteasen und zum Umbau des Kollagengewebes führen. Möglicherweise kommt es zusammen mit einem lokal wirksamen Einflußfaktor schließlich zur dystrophen Kalzifikation. Die humangenetischen Untersuchungen sprechen nicht für eine genetische Determinierung des alpha1-PI-Mangels, sondern legen eine erworbene hepatische Störung nahe.

  18. MiT family translocation renal cell carcinoma.

    Science.gov (United States)

    Argani, Pedram

    2015-03-01

    The MiT subfamily of transcription factors includes TFE3, TFEB, TFC, and MiTF. Gene fusions involving two of these transcription factors have been identified in renal cell carcinoma (RCC). The Xp11 translocation RCCs were first officially recognized in the 2004 WHO renal tumor classification, and harbor gene fusions involving TFE3. The t(6;11) RCCs harbor a specific Alpha-TFEB gene fusion and were first officially recognized in the 2013 International Society of Urologic Pathology (ISUP) Vancouver classification of renal neoplasia. These two subtypes of translocation RCC have many similarities. Both were initially described in and disproportionately involve young patients, though adult translocation RCC may overall outnumber pediatric cases. Both often have unusual and distinctive morphologies; the Xp11 translocation RCCs frequently have clear cells with papillary architecture and abundant psammomatous bodies, while the t(6;11) RCCs frequently have a biphasic appearance with both large and small epithelioid cells and nodules of basement membrane material. However, the morphology of these two neoplasms can overlap, with one mimicking the other. Both of these RCCs underexpress epithelial immunohistochemical markers like cytokeratin and epithelial membrane antigen (EMA) relative to most other RCCs. Unlike other RCCs, both frequently express the cysteine protease cathepsin k and often express melanocytic markers like HMB45 and Melan A. Finally, TFE3 and TFEB have overlapping functional activity as these two transcription factors frequently heterodimerize and bind to the same targets. Therefore, on the basis of clinical, morphologic, immunohistochemical, and genetic similarities, the 2013 ISUP Vancouver classification of renal neoplasia grouped these two neoplasms together under the heading of "MiT family translocation RCC." This review summarizes our current knowledge of these recently described RCCs. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Plattenepithelkarzinom in Verbindung mit einer roten Tätowierung.

    Science.gov (United States)

    Schmitz, Inge; Prymak, Oleg; Epple, Matthias; Ernert, Carsten; Tannapfel, Andrea

    2016-06-01

    Obwohl Tätowierungen in den letzten Jahren außerordentlich beliebt geworden sind, wurde in der Literatur bisher nur über wenige Fälle schwerer Reaktionen berichtet, die zu einer malignen Transformation führten. Dies steht im Kontrast zu der praktisch unüberschaubaren Zahl an Tätowierungen weltweit. Die Zusammensetzung der für Tätowierungen verwendeten Farbstoffe variiert stark, und selbst gleiche Farbtöne können unterschiedliche Komponenten enthalten. Das Ziel unserer Studie war es zu untersuchen, auf welche Weise Tätowierungen möglicherweise Hautkrebs auslösen können. Wir berichten über den seltenen Fall einer 24-jährigen Frau, bei der sich sieben Monate nachdem sie eine Tätowierung auf dem Fußrücken erhalten hatte in unmittelbarer Nähe des verwendeten roten Farbstoffs ein Plattenepithelkarzinom entwickelte. Die Komplikationen begannen mit einer unspezifischen Schwellung. Die Läsion wurde histologisch untersucht. Die Zusammensetzung des inkorporierten Farbstoffs wurde mittels Rasterelektronenmikroskopie in Kombination mit energiedispersiver Elementanalyse analysiert. Zur weiteren Charakterisierung wurden Thermogravimetrie und Pulverdiffraktometrie eingesetzt. Der Tätowierungsfarbstoff enthielt hauptsächlich Bariumsulfat; Spuren von Al, S, Ti, P, Mg und Cl ließen sich ebenfalls nachweisen. Bei der Analyse zeigten sich Pigmentgranula unterschiedlicher Größe. In seltenen Fällen kann Tätowierungstinte karzinogene Effekte haben, die multifaktoriell zu sein scheinen. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  20. Patient mit Ostiumstenose-Hauptstamm und Bifurkationsstenose - R. interventricularis anterior / R. diagonalis

    Directory of Open Access Journals (Sweden)

    Kerschner K

    2005-01-01

    Full Text Available Die Indikation zu Eingriffen am Hauptstamm und komplexen Bifurkationsstenosen wird auch nach Einführung von Drug-eluting- Stents und neuen Techniken kontrovers diskutiert. Im folgenden wird über eine kombinierte Hauptstamm- und Bifurkationsintervention berichtet. Anamnese: Ein 66jähriger Patient mit seit zwei Monaten zunehmender Belastungsdyspnoe Stadium III (NYHA, verbunden mit thorakalem Oppressionsgefühl. Zustand nach zerebralem Insult mit geringen Residuen, permanentes Vorhofflimmern, unzureichend eingestellte Hypertonie, geringe Nierenfunktionseinschränkung, Hypercholesterinämie. Invasive Abklärung: Ventrikulographie: ausgedehnte Akinese diaphragmal, Hypokinesie des Restventrikels, Auswurffraktion 29 %. Angiographie: 50 % Ostiumstenose-Hauptstamm, Bifurkationsstenose R. interventricularis anterior (LAD mit dem großen 1. diagonalen Ast jeweils 90 % (echte Bifurkation Typ IV ICPS-Klassifikation, Y konfiguriert (Abb. 1. Geringe Sklerose der klein angelegten A. circumflexa, proximaler Verschluß rechte Koronararterie mit Kollateralen von links zur diffus sklerotischen Peripherie. Nach entsprechender Aufklärung über die Therapiemöglichkeiten wurde eine Bypass-Operation vom Patienten nicht gewünscht und die Intervention durchgeführt. Intervention: Führungskatheter EBU 4 7F (Launcher, Medtronic. Sondierung beider Äste mit einem BMW-Führungsdraht (Balance Middleweight, Guidant Corp. und sequentielle Vordehnung R. diagonalis und LAD mit einem 2,5 / 20 mm-Ballon (Hypro Pegaso Sorin, Biomedica mit 16 atm. Plazierung eines 2,75 / 24 mm-Taxus-Express-2-Stent (Boston Scientific im R. diagonalis und eines 3,0 / 28 mm-Taxus-Express-2-Stent im LAD und Implantation in Crush-Technik (Abb. 2, jeweils 14 atm, mit dem Stent im R. diagonalis als gecrushtem Stent. Resondierung des R. diagonalis und Vordehnung des Abganges mit einem 1,5 und 2,5 mm-Ballon mit 20 atm und anschließende Kissing-Ballondilatation R. diagonalis 2,5 mm und LAD 3,0 mm

  1. The IS Services Agency of Wittenheim sets the pace in numerical radiography; L'agence IS Services de Wittenheim a la pointe de la radiographie numerique

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2006-03-15

    Small by its size with only 5 workers, the IS Services Agency of Wittenheim (Alsace) is however ultra specialized in nondestructive testing, and particularly with the new technology of the numerical radiography. (O.M.)

  2. Impact of chest radiography for children with lower respiratory tract infection: a propensity score approach.

    Directory of Open Access Journals (Sweden)

    Emmanuelle Ecochard-Dugelay

    Full Text Available BACKGROUND: Management of acute respiratory tract infection varies substantially despite this being a condition frequently encountered in pediatric emergency departments. Previous studies have suggested that the use of antibiotics was higher when chest radiography was performed. However none of these analyses had considered the inherent indication bias of observational studies. OBJECTIVE: The aim of this work was to assess the relationship between performing chest radiography and prescribing antibiotics using a propensity score analysis to address the indication bias due to non-random radiography assignment. METHODS: We conducted a prospective study of 697 children younger than 2 years of age who presented during the winter months of 2006-2007 for suspicion of respiratory tract infection at the Pediatric Emergency Department of an urban general hospital in France (Paris suburb. We first determined the individual propensity score (probability of having a chest radiography according to baseline characteristics. Then we assessed the relation between radiography and antibiotic prescription using two methods: adjustment and matching on the propensity score. RESULTS: We found that performing a chest radiography lead to more frequent antibiotic prescription that may be expressed as OR = 2.3, CI [1.3-4.1], or as an increased use of antibiotics of 18.6% [0.08-0.29] in the group undergoing chest radiography. CONCLUSION: Chest radiography has a significant impact on the management of infants admitted for suspicion of respiratory tract infection in a pediatric emergency department and may lead to unnecessary administration of antibiotics.

  3. The review of the application of neutron radiography to thermal hydraulic research

    CERN Document Server

    Mishima, K; Saitô, Y; Nakamura, H; Matsubayashi, M

    1999-01-01

    This paper is concerned with the establishment of thermal neutron radiography as a high accuracy measurement method. This paper reviews the present status on the development of high-frame-rate neutron radiography with a steady thermal neutron beam and its application to multiphase flow research performed at the Research Reactor Institute of Kyoto University in collaboration with the Japan Atomic Energy Research Institute.

  4. 75 FR 57080 - In the Matter of Aerotest Operations, Inc. (Aerotest Radiography and Research Reactor); Order...

    Science.gov (United States)

    2010-09-17

    ... COMMISSION In the Matter of Aerotest Operations, Inc. (Aerotest Radiography and Research Reactor); Order... Aerotest Operations, Inc., (Aerotest, the licensee) is the holder of Facility Operating License No. R-98 which authorizes the possession, use, and operation of the Aerotest Radiography and Research Reactor...

  5. 75 FR 39985 - In the Matter of Aerotest Operations, Inc. (Aerotest Radiography and Research Reactor); Order...

    Science.gov (United States)

    2010-07-13

    ... COMMISSION In the Matter of Aerotest Operations, Inc. (Aerotest Radiography and Research Reactor); Order Approving Indirect Transfer of Facility Operating License and Conforming Amendment I. Aerotest Operations..., use and operation of the Aerotest Radiography and Research Reactor (ARRR) located in San Ramon...

  6. 78 FR 46618 - Order Prohibiting Operation of Aerotest Radiography and Research Reactor

    Science.gov (United States)

    2013-08-01

    ... COMMISSION Order Prohibiting Operation of Aerotest Radiography and Research Reactor I. Aerotest Operations... Licensing of Production and Utilization Facilities.'' The license authorizes the operation of the Aerotest Radiography and Research Reactor (ARRR) in accordance with the conditions specified therein. The ARRR is...

  7. 75 FR 27368 - Aerotest Operations, Inc., Aerotest Radiography and Research Reactor; Notice of Consideration of...

    Science.gov (United States)

    2010-05-14

    ... COMMISSION Aerotest Operations, Inc., Aerotest Radiography and Research Reactor; Notice of Consideration of... INFORMATION CONTACT: Cindy Montgomery, Project Manager, Research and Test Reactors Licensing Branch, Division... Operating License No. R-98 for the Aerotest Radiography and Research Reactor (ARRR), currently held by...

  8. Neutron radiography and other NDE tests of main rotor helicopter blades

    CSIR Research Space (South Africa)

    De Beer, FC

    2004-10-01

    Full Text Available leading to aircraft structural failures, are addressed by various NDE techniques. In a combined investigation by means of visual inspection, X-ray radiography and shearography on helicopter main rotor blades, neutron radiography (NRad) at SAFARI-1 research...

  9. Revisited the mathematical derivation wall thickness measurement of pipe for radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hamzah, A.R.; Amir, S.M.M. [Non Destructive Testing(NDT) Group, Industrial Technology Div., Malaysian Nuclear Agency, Selangor (Malaysia)

    2007-07-01

    Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the Pythagoras theorem and geometrical principles. In order to derive the maximum penetration wall thickness a similar approach is used. (authors)

  10. Rheumatoid arthritis bone erosion volumes on CT and MRI: reliability and correlations with erosion scores on CT, MRI and radiography

    DEFF Research Database (Denmark)

    Møller Døhn, Uffe; Ejbjerg, Bo J; Hasselquist, Maria;

    2007-01-01

    controls underwent unilateral CT, MRI and radiography of second to fifth MCP joints in one hand. Erosion volumes (using OSIRIS software) and scores were determined from CT, MRI and radiography (scores only). RESULTS: CT, MRI and radiography detected 77, 62 and 12 erosions, respectively. On CT, the mean...

  11. Inseltransplantation als Therapieoption bei Diabetes mellitus Typ 1: Für wen, mit welchem Ziel, mit welchem Erfolg?

    Directory of Open Access Journals (Sweden)

    Ludwig B

    2014-01-01

    Full Text Available Die Inseltransplantation hat sich als Behandlungsoption für Patienten mit Diabetes mellitus Typ 1 etabliert. In den meisten Zentren wird die Indikation gestellt, wenn konventionelle Therapiemethoden versagen und Patienten durch eine hochlabile Stoffwechsellage und rezidivierende Hypoglykämien gefährdet sind. Hintergrund für diese strikte Indikationsstellung ist die Notwendigkeit einer dauerhaften Immunsuppression und der kritische Mangel an verfügbaren Spenderorganen. Durch die Wiederherstellung einer endogenen Insulinsekretion kommt es zu einer zuverlässigen Stabilisierung des Blutzuckerprofils, Vermeidung von Hypoglykämien und Verhinderung bzw. Stabilisierung von Spätkomplikationen. Damit einher geht eine deutliche Verbesserung der Lebensqualität. Das Erreichen einer kompletten Insulinunabhängigkeit ist dabei nicht vorrangiges Therapieziel.

  12. Virtual colonoscopy with multi-slice computed tomography; Virtuelle Koloskopie mit der Mehrschichtcomputertomographie. Vorlaeufige Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Rust, G.-F.; Eisele, O.; Reiser, M. [Institut fuer Klinische Radiologie, Klinikum Grosshadern, Muenchen Univ. (Germany); Hoffmann, J.N.; Kopp, R.; Fuerst, H. [Chirurgische Klinik und Poliklinik, Klinikum der Univ. Muenchen (Germany)

    2000-03-01

    Subject: Using multi-slice computed tomography (MSCT) large body areas can scanned with high spatial resolution. In this study, MSCT was employed for virtual colonoscopy in various pathologies of the colon. Results: Nine polyps and four of five colon carcinomas were detected using MSCT virtual colonoscopy. In three patients with ulcerative colitis virtual coloscopy revealed morphological alterations compatible with this disease. In two of four patients with multiple diverticula of the colon the true extent of the disorder could be assessed in virtual colonoscopy. (orig.) [German] Fragestellung: Die Mehrschichtcomputertomographie (MSCT) vermag, grosse Organbereiche mit hoher raeumlicher Aufloesung zu untersuchen. Daher koennen auch fuer die virtuelle Koloskopie eine bisher nicht erreichbare Ortsaufloesung und Detailtreue erwartet werden. Die ersten Ergebnisse mit der MSCT-Koloskopie bei unterschiedlichen pathologischen Veraenderungen des Kolons werden vorgestellt. Ergebnisse: 4 von 5 Kolonkarzinomen konnten mit der virtuellen Koloskopie dargestellt werden. Bei 3 Patienten wurden mit der virtuellen Koloskopie typische Veraenderungen der Colitis ulcerosa dargestellt, wovon ein Patient die konventionelle Koloskopie nicht tolerierte. Bei 9 Patienten mit Kolonpolypen stimmten die virtuelle und konventionelle Koloksopie vollstaendig ueberein. Bei 4 Patienten mit Divertikulose war mit der virtuellen Koloskopie nur in 2 Faellen der Befund vollstaendig zu sichern. (orig.)

  13. Evaluation of the MIT RMID 1000 system for the identification of Listeria species.

    Science.gov (United States)

    Ricardi, John; Haavig, David; Cruz, Lasaunta; Paoli, George; Gehring, Andrew

    2010-01-01

    The Micro Imaging Technology (MIT) 1000 Rapid Microbial Identification (RMID) System is a device that uses the principles of light scattering coupled with proprietary algorithms to identify bacteria after being cultured and placed in a vial of filtered water. This specific method is for pure culture identification of Listeria spp. A total of 81 microorganisms (55 isolates) were tested by the MIT 1000 System, of which 25 were Listeria spp. and 30 a variety of other bacterial species. In addition, a total of 406 tests over seven different ruggedness parameters were tested by the MIT 1000 System to determine its flexibility to the specifications stated in the MIT 1000 System User Guide in areas where they might be deviated by a user to shorten the test cycle. Overall, MIT concluded that the MIT 1000 System had an accuracy performance that should certify this Performance Test Method for the identification of Listeria spp. This report discusses the tests performed, results achieved, and conclusions, along with several reference documents to enable a higher understanding of the technology used by the MIT 1000 System.

  14. Rekonstruktion mit Netz beim komplexen Prolaps der Frau: Was hilft es der Patientin wirklich?

    Directory of Open Access Journals (Sweden)

    Hierl J

    2010-01-01

    Full Text Available Einleitung: Der komplexe Genitaldeszensus der Frau geht oftmals mit einer deutlichen Einschränkung der Lebensqualität (LQ einher. Dennoch ist der Endpunkt der meisten klinischen Analysen rein anatomischer und funktioneller Natur. In der vorliegenden Untersuchung wurden die Einflüsse der operativen Rekonstruktion mit einem Netz prospektiv auf die LQ evaluiert. Patienten und Methoden: Bei insgesamt 111 Patientinnen mit Deszensus erfolgte zwischen 08/2005 und 12/2007 eine operative Versorgung mittels vaginaler Netzeinlage (anteriorer bzw. kompletter Mesh-Repair. Die LQ wurde prospektiv prä- und postoperativ anhand standardisierter LQ-Fragebögen erfasst. Ergebnisse: Präoperativ zeigte sich bei den Patientinnen eine signifikant reduzierte LQ gegenüber einem Normalkollektiv (p 0,01. Bei 7 % der Patientinnen mit anteriorem, und bei 11 % mit komplettem Mesh-Repair lag postoperativ kein adäquates klinisches Ergebnis vor. In diesem Kollektiv zeigte sich kein signifikanter Unterschied in den LQ-Tests prä- und postoperativ. Bei gutem postoperativem Ergebnis zeigte sich in der Gruppe mit anteriorer Netzeinlage lediglich bei 45 % (p = 0,021, bei kompletter Netzeinlage nur bei 31 % (p = 0,041 eine signifikant verbesserte LQ. Bei kleiner Fallzahl und kurzem Nachbeobachtungszeitraum kann eine gültige Aussage bezüglich der LQ nach Deszensuschirurgie mit Netzeinlage jedoch noch nicht getroffen werden.

  15. Aktuelles aus der Forschung mit menschlichen embryonalen Stammzellen (Mit dem Jahresbericht 2004 der Zentralen Ethikkommission für Stammzellenforschung

    Directory of Open Access Journals (Sweden)

    Beier HM

    2005-01-01

    Full Text Available Im internationalen Diskurs über die Forschung mit menschlichen embryonalen Stammzellen und die Perspektiven, regenerative Therapien zu entwickeln, fanden sich in jüngster Zeit bemerkenswerte Beiträge, auf die wir hier zurückgreifen. In den aufstrebenden Forschungsnationen Südkorea, Taiwan, Singapur und China läuft ein enormer Wettbewerb um die umfangreichsten Forschungsressourcen und die Führung in der embryonalen Stammzellforschung ab. In Europa und in den USA investieren Wissenschaftler Zeit, Forschungsmittel und intellektuelle Kapazität in die Suche nach Wegen, humane embryonale Stammzellen herzustellen, ohne menschliche Eizellen und Embryonen für diese Verfahren opfern zu müssen. In Deutschland finden solche Bemühungen ein positives Echo, weil das Gesetz es verbietet, embryonale Stammzellen aus verwaisten Blastozysten, sog. überzähligen Embryonen, herzustellen. Dem Stammzellgesetz gemäß kann in Deutschland nur unter Ausnahmebedingungen an menschlichen embryonalen Stammzellen geforscht werden. Wissenschaftler dürfen nach Prüfung und Genehmigung eines speziellen Projektantrages durch das Robert-Koch-Institut menschliche embryonale Stammzell-Linien von bestimmten, lizensierten, ausländischen Herstellern importieren. Allerdings müssen diese Zell-Linien vor dem Stichtag, dem 1.1.2002, hergestellt worden sein. Die Zentrale Ethik-Kommission für Stammzellenforschung (ZES, die das Robert-Koch-Institut im Auftrag der Bundesregierung berät, berichtet jedes Jahr über ihre Arbeit. Im zweiten Teil dieses Artikels wird mit freundlicher Genehmigung des Bundesministeriums für Gesundheit und Soziale Sicherheit der ZES-Jahresbericht 2004 veröffentlicht.

  16. Gebrauch von Komplementärmedizin bei Patienten mit metastasierendem Melanom unter Therapie mit Ipilimumab innerhalb einer klinischen Studie.

    Science.gov (United States)

    Huebner, Jutta; Mohr, Peter; Simon, Jan-Christoph; Fluck, Michael; Berking, Carola; Zimmer, Lisa; Loquai, Carmen

    2016-05-01

    In Deutschland wenden 40-90 % aller Krebspatienten Methoden der komplementären and alternativen Medizin (KAM) an. Bis dato gibt es kein Datenmaterial zum Einsatz der KAM bei Melanompatienten. Das Ziel unserer Studie war es, Daten über den Gebrauch, die Informationsquellen und Ziele von Patienten mit metastasierendem Melanom zu erfassen. Einhundertsechsundfünfzig Patienten aus 25 Studienzentren nahmen an der DecOG-MM-PAL Multibasket Studie teil. Die beteiligten Personen wurden auch gebeten, an einer Nebenstudie teilzunehmen, die ihren Gebrauch von KAM erfassen sollte. Dazu wurde während der Behandlung ein standardisierter Fragebogen zu genau festgelegten Zeitpunkten ausgeteilt. Insgesamt gingen 55 Fragebögen von 32 (21 %) Melanompatienten ein. Von diesen gaben 17 (53 %) ein Interesse an KAM an, und sieben (22 %) machten von KAM Gebrauch. Die Hauptinformationsquellen (31 %) waren Familienmitglieder und Freunde, gefolgt von Ärzten (19 %). Die Hauptgründe für die Anwendung von KAM waren die Stärkung des Immunsystems (41 %) und des Körpers (34 %). Nahrungsergänzungsmittel (Vitamine und Spurenelemente) wurden am häufigsten angewendet (28 %). Eine relativ hohe Anzahl an Patienten mit metastasierendem Melanom machte trotz Teilnahme an einer klinischen Studie von KAM Gebrauch. Wechselwirkungen könnten durch biologisch basierte KAM auftreten, und hier besonders bei immunmodulierenden KAM- Strategien. Um Risiken zu vermeiden, sollte die Kommunikation zwischen den Ärzten und den Patienten verbessert werden. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  17. Toward practical 3D radiography of pipeline girth welds

    Energy Technology Data Exchange (ETDEWEB)

    Wassink, Casper, E-mail: casper.wassink@applusrtd.com [Applus RTD Chief Scientist, Rivium 1e straat 80, 2909 LE Capelle a/d IJssel (Netherlands); Hol, Martijn, E-mail: martijn.hol@applusrtd.com; Flikweert, Arjan, E-mail: martijn.hol@applusrtd.com; Meer, Philip van, E-mail: martijn.hol@applusrtd.com [Applus RTD Technological Center, Delftweg 144, 3046 NC Rotterdam (Netherlands)

    2015-03-31

    Digital radiography has made its way into in-the-field girth weld testing. With recent generations of detectors and x-ray tubes it is possible to reach the image quality desired in standards as well as the speed of inspection desired to be competitive with film radiography and automated ultrasonic testing. This paper will show the application of these technologies in the RTD Rayscan system. The method for achieving an image quality that complies with or even exceeds prevailing industrial standards will be presented, as well as the application on pipeline girth welds with CRA layers. A next step in development will be to also achieve a measurement of weld flaw height to allow for performing an Engineering Critical Assessment on the weld. This will allow for similar acceptance limits as currently used with Automated Ultrasonic Testing of pipeline girth welds. Although a sufficient sizing accuracy was already demonstrated and qualified in the TomoCAR system, testing in some applications is restricted to time limits. The paper will present some experiments that were performed to achieve flaw height approximation within these time limits.

  18. Nuclear track radiography of 'hot' aerosol particles

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, S.F.; Kievitskaja, A.I.; Kievets, M.K.; Lomonosova, E.M.; Zhuk, I.V.; Yaroshevich, O.I.; Perelygin, V.P.; Petrova, R.; Brandt, R.; Vater, P

    1999-06-01

    Nuclear track radiography was applied to identify aerosol 'hot' particles which contain elements of nuclear fuel and fallout after Chernobyl NPP accident. For the determination of the content of transuranium elements in radioactive aerosols the measurement of the {alpha}-activity of 'hot' particles by SSNTD was used in this work, as well as radiography of fission fragments formed as a result of the reactions (n,f) and ({gamma},f) in the irradiation of aerosol filters by thermal neutrons and high energy gamma quanta. The technique allowed the sizes and alpha-activity of 'hot' particles to be determined without extracting them from the filter, as well as the determination of the uranium content and its enrichment by {sup 235}U, {sup 239}Pu and {sup 241}Pu isotopes. Sensitivity of determination of alpha activity by fission method is 5x10{sup -6} Bq per particle. The software for the system of image analysis was created. It ensured the identification of track clusters on an optical image of the SSNTD surface obtained through a video camera and the determination of size and activity of 'hot' particles00.

  19. Magnetic resonance imaging and computed radiography in Achilles tendon rupture

    Energy Technology Data Exchange (ETDEWEB)

    Korenaga, Tateo; Hachiya, Junichi; Miyasaka, Yasuo and others

    1988-11-01

    Magnetic Resonance Imaging (MRI) and Computed Radiography (CR) were performed in 15 patients with complete Achilles tendon rupture who were treated conservatively without surgery. MRI was obtained using Toshiba MRT 50 A superconductive machine, operaing at 0.5 Tesla. CR was performed by CR-101, Fuji Medical System. In fresh cases, ruptured tendons showed intermediate signal intensity on T1-weighted images and high intensity on T2-weighted images. Thickening of the tendon was observed in all cases except in very acute stage. Configuration of thickend tendons tends to be dumbbell shape in subacute stage and fusiform in chronic stage of more than six months after the initial trauma. In cases which showed high signal intensity at the ruptured area both on T1 and T2 weighted images, migration of fat into the sapces between the ruptured tendons was considered to be the major source of increased signal intensity. Computed radiography showed thickening of the tendon, blurring of anterior margin of the tendon, and decreased translucency of pre-Achilles fat pad. However, MRI better demonstrated the details of ruptured tendons when compared to CR, and thought to be an usefull way of following up the healing process of the ruptured tendon to facilitate more reasonable judgement of the time of removing plaster casts and stating exercise.

  20. Stenosis of calcified carotid artery detected on Panoramic Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Cho, So Yang; Oh, Won Mann; Yoon, Suk Ja; Yoon, Woong; Lee, Jae Seo; Kang, Byung Cheol [School of Dentistry, Chonnam National University, Seoul (Korea, Republic of); Palomo, Juan M. [Department of Orthodontics, School of Dental Medicine, Case Western Reserve University, Cleveland (United States)

    2009-09-15

    This study aimed to investigate the luminal stenosis of the internal carotid artery with calcification detected on panoramic radiographs. This study used fifty carotid arteries of 36 dental patients whose panoramic radiograph and computed tomography angiography (CTA) revealed the presence of carotid artery calcification. A neuroradiologist interpreted CTA to determine the degree of stenosis of the internal carotid arteries. The degree of stenosis was stratified in four stages; normal (no stenosis), mild stenosis (1-49%), moderate stenosis (50-69%) and severe stenosis (70-99%). Among the fifty carotid arteries with calcification detected on both panoramic radiography and CTA, 20 carotid arteries (40%) were normal, 29 carotid arteries (18%) had mild stenosis, 1 carotid artery (2%) had moderate stenosis, and there was none with severe stenosis. Sixty percent of the carotid arteries with calcification detected on both panoramic radiography and CTA had internal luminal stenosis, and two percent had moderate stenosis. When carotid atheroma is detected on panoramic radiograph, it is possible that the dental patient has luminal stenosis of the internal carotid artery.

  1. Digital luminescent radiography for diagnosis of skeletal injuries

    Energy Technology Data Exchange (ETDEWEB)

    Buddenbrock, B. [Central Inst. for Radiological Diagnostics, University Hospital of GHS Essen (Germany); Mueller, R.D. [Central Inst. for Radiological Diagnostics, University Hospital of GHS Essen (Germany); John, V. [Central Inst. for Radiological Diagnostics, University Hospital of GHS Essen (Germany); Kock, H.J. [Dept. of Traumatology, University Hospital of GHS Essen (Germany); Hirche, H. [Inst. of Medical Informatics and Biomathematics, Univ. Hospital of GHS Essen (Germany); Voss, M. [Central Inst. for Radiological Diagnostics, University Hospital of GHS Essen (Germany); Loehr, E. [Central Inst. for Radiological Diagnostics, University Hospital of GHS Essen (Germany); Schmit-Neuerburg, K.P. [Dept. of Traumatology, University Hospital of GHS Essen (Germany)

    1992-12-01

    In the course of a comparative study 231 patients with traumatic lesions in skeletal and soft tissue areas were X-rayed using conventional film radiography and digital luminescence radiography (DLR). The results were evaluated by radiologists and traumatologists on the basis of optimised image post-processing in addition to the standard digital presentations. The imaging quality of compacta, spongiosa, soft tissues, fracture lines and osteosynthesis material was assessed in comparison with the screen-film images. Whereas the standard digital presentation in the ``conventionally adjusted`` imaging mode was inferior to the screen-film radiograph, the ``edge-enhanced`` standard presentation proved to be advantageous in the imaging of soft tissues (frequency of first-place ratings: DLR conventional 6%, screen-film system 21%, DLR edge-enhanced 31%). In the overall evaluation high-frequency filtered inverse image post-processing showed the highest diagnostic potential (frequency of first-place ratings: 41%). A conclusive assessment of metal implants is hindered by overshoot artefacts and can only be achieved through time-consuming post-processing of the stored image data. (orig.)

  2. A note on digital dental radiography in forensic odontology.

    Science.gov (United States)

    Chiam, Sher-Lin

    2014-09-01

    Digital dental radiography, intraoral and extraoral, is becoming more popular in dental practice. It offers convenience, such as lower exposure to radiation, ease of storing of images, and elimination of chemical processing. However, it also has disadvantages and drawbacks. One of these is the potential for confusion of the orientation of the image. This paper outlines one example of this, namely, the lateral inversion of the image. This source of confusion is partly inherent in the older model of phosphor storage plates (PSPs), as they allow both sides to be exposed without clue to the fact that the image is acquired on the wrong side. The native software allows digital manipulation of the X-ray image, permitting both rotation and inversion. Attempts to orientate the X-ray according to the indicator incorporated on the plate can then sometimes lead to inadvertent lateral inversion of the image. This article discusses the implications of such mistakes in dental digital radiography to forensic odontology and general dental practice.

  3. Low material budget floating strip Micromegas for ion transmission radiography

    Science.gov (United States)

    Bortfeldt, J.; Biebel, O.; Flierl, B.; Hertenberger, R.; Klitzner, F.; Lösel, Ph.; Magallanes, L.; Müller, R.; Parodi, K.; Schlüter, T.; Voss, B.; Zibell, A.

    2017-02-01

    Floating strip Micromegas are high-accuracy and discharge insensitive gaseous detectors, able to track single particles at fluxes of 7 MHz/cm2 with 100 μm resolution. We developed low-material-budget detectors with one-dimensional strip readout, suitable for tracking at highest particle rates as encountered in medical ion transmission radiography or inner tracker applications. Recently we additionally developed Kapton-based floating strip Micromegas with two-dimensional strip readout, featuring an overall thickness of 0.011 X0. These detectors were tested in high-rate proton and carbon-ion beams at the tandem accelerator in Garching and the Heidelberg Ion-Beam Therapy Center, operated with an optimized Ne:CF4 gas mixture. By coupling the Micromegas detectors to a new scintillator based range detector, ion transmission radiographies of PMMA and tissue-equivalent phantoms were acquired. The range detector with 18 layers is read out via wavelength shifting fibers, coupled to a multi-anode photomultiplier. We present the performance of the Micromegas detectors with respect to timing and single plane track reconstruction using the μTPC method. We discuss the range resolution of the scintillator range telescope and present the image reconstruction capabilities of the combined system.

  4. Reliability of panoramic radiography in chronological age estimation

    Directory of Open Access Journals (Sweden)

    Ramanpal Singh Makkad

    2013-01-01

    Full Text Available Introduction: There has been a strong relationship between the growth rate of bone and teeth, which can be utilized for the purpose of age identification of an individual. Aims and Objective: The present study was designed to determine the relationship between the dental age, the age from dental panoramic radiography, skeletal age, and chronological age. Materials and Methods: The study included 270 individuals, averaging between 17 years and 25 years of age from out-patient department of New Horizon Dental College and Hospital, Sakri, Bilaspur, Chhattisgarh, India, for third molar surgery. Panoramic and hand wrist radiographs were taken, the films were digitally processed for visualization of the wisdom teeth. The confirmations of ages were repeated again at an interval of 4 weeks by a radiologist. The extracted wisdom teeth were placed in 10% formalin and were examined by one dental surgeon to estimate the age on the basis of root formation. Student′s t-test was adopted for statistical analysis and probability (P value was calculated. Conclusion: Estimating the age of an individual was accurate by examining extracted third molar. Age estimation through panoramic radiography was highly accurate in upper right quadrant (mean = 0.72 and P = 0.077.

  5. Building a cost efficient digital radiography system for educational purposes

    Science.gov (United States)

    Brown, Chris

    Due to the growing need for Medical Physicists, many universities are implementing a Medical Physics program into their academic catalog. To help establish a new program, feasible equipment may be needed to help academic departments provide a hands-on experience for students and help teach the basic concepts of Medical Physics. For example, clinical Digital Radiography Systems (DRS) are used to help teach the basic concepts of digital imaging. However, such systems can cost in excess of 100,000, creating a financial obstacle that will be difficult to overcome. Hence, the development of a cost efficient digital radiography system may be desired in order to eliminate the financial obstacle and give students a hands-on learning experience. This DRS uses three main components to develop an image, an x-ray source, an intensifying plate, and a charge-coupled device (CCD) camera. All three components are housed in a lead-lined box. The purpose of this project is to find the limitations of our DRS and compare the price between our DRS and commercially available DRSs. At optimal settings, a SNR of 25 is shown across the intensifying screen that can identify objects as small as 0.42mm. A Contrast-detail phantom shows the ability to decipher the varying thickness of foam rubber squares. The total cost of our DRS comes to 17,000.00, a fractional price tag compared to a commercially available DRS.

  6. Plausible scenarios for the radiography profession in Sweden in 2025.

    Science.gov (United States)

    Björkman, B; Fridell, K; Tavakol Olofsson, P

    2017-11-01

    Radiography is a healthcare speciality with many technical challenges. Advances in engineering and information technology applications may continue to drive and be driven by radiographers. The world of diagnostic imaging is changing rapidly and radiographers must be proactive in order to survive. To ensure sustainable development, organisations have to identify future opportunities and threats in a timely manner and incorporate them into their strategic planning. Hence, the aim of this study was to analyse and describe plausible scenarios for the radiography profession in 2025. The study has a qualitative design with an inductive approach based on focus group interviews. The interviews were inspired by the Scenario-Planning method. Of the seven trends identified in a previous study, the radiographers considered two as the most uncertain scenarios that would have the greatest impact on the profession should they occur. These trends, labelled "Access to career advancement" and "A sufficient number of radiographers", were inserted into the scenario cross. The resulting four plausible future scenarios were: The happy radiographer, the specialist radiographer, the dying profession and the assembly line. It is suggested that "The dying profession" scenario could probably be turned in the opposite direction by facilitating career development opportunities for radiographers within the profession. Changing the direction would probably lead to a profession composed of "happy radiographers" who are specialists, proud of their profession and competent to carry out advanced tasks, in contrast to being solely occupied by "the assembly line". Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  7. Inverse-collimated proton radiography for imaging thin materials

    Science.gov (United States)

    Freeman, Matthew S.; Allison, Jason; Andrews, Malcolm; Ferm, Eric; Goett, John J.; Kwiatkowski, Kris; Lopez, Julian; Mariam, Fesseha; Marr-Lyon, Mark; Martinez, Michael; Medina, Jason; Medina, Patrick; Merrill, Frank E.; Morris, Chris L.; Murray, Matthew M.; Nedrow, Paul; Neukirch, Levi P.; Prestridge, Katherine; Rigg, Paolo; Saunders, Alexander; Schurman, Tamsen; Tainter, Amy; Trouw, Frans; Tupa, Dale; Tybo, Josh; Vogan-McNeil, Wendy; Wilde, Carl

    2017-01-01

    Relativistic, magnetically focused proton radiography was invented at Los Alamos National Laboratory using the 800 MeV LANSCE beam and is inherently well-suited to imaging dense objects, at areal densities >20 g cm-2. However, if the unscattered portion of the transmitted beam is removed at the Fourier plane through inverse-collimation, this system becomes highly sensitive to very thin media, of areal densities <100 mg cm-2. Here, this inverse-collimation scheme is described in detail and demonstrated by imaging Xe gas with a shockwave generated by an aluminum plate compressing the gas at Mach 8.8. With a 5-mrad inverse collimator, an areal density change of just 49 mg cm-2 across the shock front is discernible with a contrast-to-noise ratio of 3. Geant4 modeling of idealized and realistic proton transports can guide the design of inverse-collimators optimized for specific experimental conditions and show that this technique performs better for thin targets with reduced incident proton beam emittance. This work increases the range of areal densities to which the system is sensitive to span from ˜25 mg cm-2 to 100 g cm-2, exceeding three orders of magnitude. This enables the simultaneous imaging of a dense system as well as thin jets and ejecta material that are otherwise difficult to characterize with high-energy proton radiography.

  8. Inverse-collimated proton radiography for imaging thin materials.

    Science.gov (United States)

    Freeman, Matthew S; Allison, Jason; Andrews, Malcolm; Ferm, Eric; Goett, John J; Kwiatkowski, Kris; Lopez, Julian; Mariam, Fesseha; Marr-Lyon, Mark; Martinez, Michael; Medina, Jason; Medina, Patrick; Merrill, Frank E; Morris, Chris L; Murray, Matthew M; Nedrow, Paul; Neukirch, Levi P; Prestridge, Katherine; Rigg, Paolo; Saunders, Alexander; Schurman, Tamsen; Tainter, Amy; Trouw, Frans; Tupa, Dale; Tybo, Josh; Vogan-McNeil, Wendy; Wilde, Carl

    2017-01-01

    Relativistic, magnetically focused proton radiography was invented at Los Alamos National Laboratory using the 800 MeV LANSCE beam and is inherently well-suited to imaging dense objects, at areal densities >20 g cm(-2). However, if the unscattered portion of the transmitted beam is removed at the Fourier plane through inverse-collimation, this system becomes highly sensitive to very thin media, of areal densities <100 mg cm(-2). Here, this inverse-collimation scheme is described in detail and demonstrated by imaging Xe gas with a shockwave generated by an aluminum plate compressing the gas at Mach 8.8. With a 5-mrad inverse collimator, an areal density change of just 49 mg cm(-2) across the shock front is discernible with a contrast-to-noise ratio of 3. Geant4 modeling of idealized and realistic proton transports can guide the design of inverse-collimators optimized for specific experimental conditions and show that this technique performs better for thin targets with reduced incident proton beam emittance. This work increases the range of areal densities to which the system is sensitive to span from ∼25 mg cm(-2) to 100 g cm(-2), exceeding three orders of magnitude. This enables the simultaneous imaging of a dense system as well as thin jets and ejecta material that are otherwise difficult to characterize with high-energy proton radiography.

  9. Time-gated energy-selected cold neutron radiography

    CERN Document Server

    McDonald, T E; Claytor, T N; Farnum, E H; Greene, G L; Morris, C

    1999-01-01

    A technique is under development at the Los Alamos Neutron Science Center (LANSCE), Manuel Lujan Jr. Neutron Scattering Center (Lujan Center) for producing neutron radiography using only a narrow energy range of cold neutrons. The technique, referred to as time-gated energy-selected (TGES) neutron radiography, employs the pulsed neutron source at the Lujan Center with time of flight to obtain a neutron pulse having an energy distribution that is a function of the arrival time at the imager. The radiograph is formed on a short persistence scintillator and a gated, intensified, cooled CCD camera is employed to record the images, which are produced at the specific neutron energy range determined by the camera gate. The technique has been used to achieve a degree of material discrimination in radiographic images. For some materials, such as beryllium and carbon, at energies above the Bragg cutoff the neutron scattering cross section is relatively high while at energies below the Bragg cutoff the scattering cross ...

  10. Assessing The Impact Of Computed Radiography And PACS

    Science.gov (United States)

    Hedgcock, Marcus W.; Kehr, Katherine

    1989-05-01

    Our institution (San Francisco VA Medical Center) is a VA pilot center for total digital imaging and PACS. Quantitative information about PACS impact on health care is limited, because no centers have done rigorous preimplementation studies. We are gathering quantitative service delivery and cost data before, during, and after stepwise implementation of computed radiography and PACS at our institution to define the impact on imaging service delivery. We designed a simple audit method using the x-ray request and time clocks to determine patient waiting time, imaging time, film use, image availability to the radiologist, matching of current with previous images, image availability to clinicians, and time to final interpretation. Our department model is a multichannel, mulitserver patient queue. Our current radiograph file is space limited, containing only one year of images; older images are kept in a remote file area in another building. In addition, there are 16 subfile areas within the Radiology Service and the medical center. Our preimplementation audit showed some long waiting times (40 minutes, average 20) and immediate retrieval of prior films in only 42% of cases, with an average retrieval time of 22 hours. Computed radiography and the optical archive have the potential to improve these figures. The audit will be ongoing and automated as implementation of PACS progresses, to measure service improvement and learning curve with the new equipment. We present the audit format and baseline preimplementation figures.

  11. A note on digital dental radiography in forensic odontology

    Directory of Open Access Journals (Sweden)

    Sher-Lin Chiam

    2014-01-01

    Full Text Available Digital dental radiography, intraoral and extraoral, is becoming more popular in dental practice. It offers convenience, such as lower exposure to radiation, ease of storing of images, and elimination of chemical processing. However, it also has disadvantages and drawbacks. One of these is the potential for confusion of the orientation of the image. This paper outlines one example of this, namely, the lateral inversion of the image. This source of confusion is partly inherent in the older model of phosphor storage plates (PSPs, as they allow both sides to be exposed without clue to the fact that the image is acquired on the wrong side. The native software allows digital manipulation of the X-ray image, permitting both rotation and inversion. Attempts to orientate the X-ray according to the indicator incorporated on the plate can then sometimes lead to inadvertent lateral inversion of the image. This article discusses the implications of such mistakes in dental digital radiography to forensic odontology and general dental practice.

  12. Radiography and tomography using fission neutrons at FRM-II

    Energy Technology Data Exchange (ETDEWEB)

    Buecherl, T.; Lierse von Gostomski, Ch. [Inst. fuer Radiochemie, TU-Muenchen, Garching (Germany)

    2004-07-01

    Fission neutrons offer complementary information in radiography and tomography compared to the well established techniques using X-rays, gamma-rays, thermal or cold neutrons. They penetrate thick layers of high density materials with only little attenuation, while for light, specially for hydrogen containing materials, their attenuation is high. In the past, fast neutrons for NDT (non-destructive testing) were only available at accelerator driven systems. These high energy neutrons have to be moderated to achieve acceptable detection efficiencies thus drastically reducing the available neutron intensities and either resulting in a high beam divergence or in additional losses in neutron intensities due to beam collimation. The recently installed neutron computerized tomography and radiography system NECTAR at the Forschungsreaktor Muenchen-II (FRM-II) overcomes these disadvantages by using fission neutrons of about 1.7 MeV mean energy created in two converter plates set-up of highly enriched uranium. The beam quality, i.e. the neutron divergence can be adapted to the object to be measured by using different collimators, resulting in L/D-values up to 300. The available neutron beam intensity at the measuring position is up to 1.7E+08 cm{sup -2} s{sup -1} for a maximum beam area of 40 cm x 40 cm. For conventional imaging a two-dimensional detector system based on a CCD-camera is used, other more specialised systems are available. (author)

  13. Methods for teaching effective patient communication techniques to radiography students.

    Science.gov (United States)

    Makely, S

    1990-07-01

    Teaching students to communicate effectively with patients has always been part of the radiography curriculum in the USA. However, developing these skills has become even more important in recent times due to several factors. Patients who have been well versed in what to expect from the examination being conducted are in a better position to co-operate with the radiographer. This increases the chances of producing optimal results from an examination at the first attempt, thus reducing radiation exposure, patient discomfort and the overall cost of conducting the procedure. Also, increased competition among health care providers has resulted in more emphasis being placed on patient, or customer, satisfaction. Radiographers are in the 'front line' of patient care. Patients often have more interaction with radiographers than with physicians or other medical specialists. Radiographers who practise effective communication techniques with their patients can alleviate anxiety and make an important contribution to the overall satisfaction of the patient with respect to the quality of service and care they receive. This article describes instructional methods being used in the USA to help develop effective patient communication techniques, and reports the findings of a study among radiography educators as to which of these methods are thought to be most successful.

  14. Facial exposure dose assessment during intraoral radiography by radiological technologists

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Hwan; Yang, Han Joon [Dept. of International Radiological Science, Hallym University of Graduate Studies, Chuncheon (Korea, Republic of)

    2014-09-15

    The study examined the changes in the decreased facial exposure dose for radiological technologists depending on increased distance between the workers and the X-ray tube head during intraoral radiography. First, the facial phantom similar to the human tissues was manufactured. The shooting examination was configured to the maxillary molars for adults (60 kVp, 10 mA, 50 msec) and for children (60 kVp, 10 mA, 20 msec), and the chamber was fixed where the facial part of the radiation worker would be placed using the intraoral radiography equipment. The distances between the X-ray tube head and the phantom were set to 10 cm, 15 cm, 20 cm, 25 cm, 30 cm, 35 cm, and 40 cm. The phantom was radiated 20 times with each examination condition and the average scattered doses were examined. The rate at the distance of 40 cm decreased by about 92.6% to 7.43% based on the scattered rays radiated at the distance of 10 cm under the adult conditions. The rate at the distance of 40 cm decreased by about 97.6% to 2.58% based on the scattered rays radiated at the distance of 10 cm under the children conditions. Protection from the radiation exposure was required during the dental radiographic examination.

  15. Manufacturing details by Neutron Radiography of Archaeological Pottery

    Energy Technology Data Exchange (ETDEWEB)

    Bernedo, Alfredo Victor Bellido; Latini, Rose Mary [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil); Souza, Maria Ines Silvani; Vinagre Filho, Ubirajara Maribondo [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    Full text: The aim of the present work was to investigate manufacturing details of archaeological pot-sherds ceramics by Neutron Radiography. Pottery is perhaps the most important artefact found in excavation. Its archaeological importance relies on the fact that it can reveal cultural traditions and commercial influences in ancient communities. These pottery was recently discovered in archaeological earth circular structures sites in Acre state Brazil and the characteristics of clay used in their manufacture have been studied by modern scientific techniques such as Instrumental Neutron Activation Analysis (INAA), Thermoluminescence Dating and Moessbauer Spectroscopy. Different fragments of pottery were submitted to a neutron flux of the order of 10{sup 5}n.cm{sup -2}2:s{sup -1} for 3 minutes in the research reactor Argonauta at the Instituto de Engenharia Nuclear/CNEN. Digital processing techniques using imaging plate were applied to the image of the selected sample. The Neutrongraphy shows two different manufacturing details: palette and rollers. The fragment made by the technique of palette show a homogeneous mass and the neutrongraphy of ceramic fragments made by the technique of the rollers, pottery funeral, can be seen horizontal traces of the junction of rollers, overlapping, forming layers supported on each other. This technique allows you to create more stable structures. Thus, both the technique of the pallet as the roller can be characterized by Neutron Radiography. (author)

  16. The need for skull radiography in patients presenting for CT

    Energy Technology Data Exchange (ETDEWEB)

    Tress, B.M.

    1983-01-01

    One thousand patients had both CT of the head and a conventional skull series of radiographs. Radiographic findings were abnormal in 250 patients (25%), but only 64 patients (6.4%) had diagnostically significant abnormalities at radiography that were not detected by CT. If the 163 patients who presented after acute trauma were excluded from the series, only 39 (4.7%) of the remaining patients had radiographically significant abnormal findings that were not seen at CT, and only two (0.2%) of these abnormalities could not be diagnosed by a lateral skull radiograph alone. In only five patients (0.5%) was the management actively changed because an abnormaltiy that was detected at skull radiography was not detected at CT. Thus, in nontrauma patients who have stroke, epilepsy, dementia, or non-specific symptoms without focal signs, or have recently undergone craniotomy, and who have been referred for CT, skull radiographs are not justified. In the patient with a history and findings that are strongly suggestive of a pathological disorder anywhere other than in the sella turcica, cerebello-pontine angle, and paranasal sinuses, only the lateral skull radiograph should be obtained after CT, and only if CT is equivocal.

  17. Erhöhter oxidativer Streß bei Patienten mit instabiler Angina pectoris

    Directory of Open Access Journals (Sweden)

    Bodlaj G

    1998-01-01

    Full Text Available Die instabile Angina pectoris führt oft zum akuten Myokardinfarkt. Da die Lipid-Peroxidation im Verdacht steht, chronische und akute Ereignisse der Atherosklerose und der koronaren Herzkrankheit zu fördern, untersuchten wir die Lipid-Peroxidations-Parameter und alpha-Toco-pherol-Spiegel bei 100 KHK-Patienten und verglichen sie mit denen einer entprechenden Kontrollgruppe. 50 konsekutive Patienten mit stabiler Angina pectoris (SAP und 50 konsekutive Patienten mit instabiler Angina pectoris (IAP wurden untersucht und mit 100 klinisch gesunden Personen verglichen. Zusätzlich zur herkömmlichen Lipid- und Lipoprotein-Analyse wurden die Lipid-Peroxidations-Produkte als Hydroperoxide und Thiobarbituric acid reactive substances (TBARS gemessen. Die konjugierten Diene wurden nur bei den Patienten bestimmt. Da alpha-Tocopherol eines der wichtigsten Antioxidantien ist, wurde es ebenfalls quantifiziert. Wie erwartet hatten die Patienten wesentlich höhere Cholesterin-, Triglyzerid-, LDL-C- und Lp(a-Spiegel und niedrigere HDL-C-Spiegel als die Kontrollgruppe. Als die Patienten in Gruppen mit stabiler und instabiler Angina pectoris geteilt wurden, waren Peroxide und TBARS in der letzteren Gruppe wesentlich höher als bei den anderen Patienten und der Kontrollgruppe. Auch konjugierte Diene waren eindeutig höher bei den Patienten mit instabiler Angina pectoris. Der alpha-Tocopherol-Gesamtspiegel war in allen 3 Gruppen vergleichbar, aber der alpha-Tocopherol-Gehalt pro LDL-Partikel war bei den Patienten mit IAP am niedrigsten, gefolgt von denen mit SAP und der Kontrollgruppe. Wir schließen daraus, daß die Lipid-Peroxidations-Parameter bei Patienten mit IAP erhöht sind und SAP-Patienten von IAP-Patienten unterscheiden.

  18. Einfluss der operativen Behandlung auf die Entwicklung von Kindern mit nonsyndromaler Kraniosynostose

    OpenAIRE

    Azouz, J. (Jamila-Stephanie)

    2008-01-01

    Ziel der Studie war die Klärung der Frage, ob eine Operation die psychomotorische Entwicklung von Kindern mit nonsyndromaler Nahtsynostose positiv beeinflussen kann. Dafür wurde die Entwicklung von 52 operierten und nicht operierten Kindern untersucht. Die Entwicklungsdiagnostik wurde mit Hilfe des ET 6-6 zum Zeitpunkt der Erstdiagnostik, 0 bis 6 sowie 6 bis 12 Monate nach der Operation durchgeführt. Zunächst wurden die Daten der operierten mit denen der nicht operierten Kinder verglichen. In...

  19. Is radiography justified for the evaluation of patients presenting with cervical spine trauma?

    Energy Technology Data Exchange (ETDEWEB)

    Theocharopoulos, Nicholas; Chatzakis, Georgios; Damilakis, John [Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 2208, Iraklion, 71003 Crete (Greece) and Department of Natural Sciences, Technological Education Institute of Crete, P.O. Box 140, Iraklion 71004 Crete (Greece); Department of Radiology, Faculty of Medicine, University of Crete, P.O. Box 2208, Iraklion, 71003 Crete (Greece); Department of Medical Physics, Faculty of Medicine, University of Crete, P.O. Box 2208, Iraklion, 71003 Crete (Greece)

    2009-10-15

    Conventional radiography has been for decades the standard method of evaluation for cervical spine trauma patients. However, currently available helical multidetector CT scanners allow multiplanar reconstruction of images, leading to increased diagnostic accuracy. The purpose of this study was to determine the relative benefit/risk ratio between cervical spine CT and cervical spine radiography and between cervical spine CT and cervical spine radiography, followed by CT as an adjunct for positive findings. A decision analysis model for the determination of the optimum imaging technique was developed. The sensitivity and specificity of CT and radiography were obtained by dedicated meta-analysis. Lifetime attributable risk of mortal cancer from CT and radiography was calculated using updated organ-specific risk coefficients and organ-absorbed doses. Patient organ doses from radiography were calculated using Monte Carlo techniques, simulated exposures performed on an anthropomorphic phantom, and thermoluminescence dosimetry. A prospective patient study was performed regarding helical CT scans of the cervical spine. Patient doses were calculated based on the dose-length-product values and Monte Carlo-based CT dosimetry software program. Three groups of patient risk for cervical spine fracture were incorporated in the decision model on the basis of hypothetical trauma mechanism and clinical findings. Radiation effects were assessed separately for males and females for four age groups (20, 40, 60, and 80 yr old). Effective dose from radiography amounts to 0.050 mSv and from a typical CT scan to 3.8 mSv. The use of CT in a hypothetical cohort of 10{sup 6} patients prevents approximately 130 incidents of paralysis in the low risk group (a priori fracture probability of 0.5%), 500 in the moderate risk group (a priori fracture probability of 2%), and 5100 in the high risk group (a priori fracture probability of 20%). The expense of this CT-based prevention is 15-32 additional

  20. Computed radiography (FCR) with a dual side reading system. Comparison with conventional radiography for visualization of nodular lung cancers

    Energy Technology Data Exchange (ETDEWEB)

    Ha-kawa, Shangkil; Yoshida, Tsunetaka; Sougawa, Mitsuharu; Harima, Yohko; Sawada, Satoshi [Kansai Medical Univ., Moriguchi, Osaka (Japan)

    2003-02-01

    To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was 31% in large nodular shadows, 40% in accompanying shadows with a nodule, 67% of small nodular shadows, and 43% of the lymph node swelling in the hilum of the lung or mediastinum. In large nodular shadows which were the most frequent abnormality score +1 or +2 were observed in 43% of adenocarcinoma and 26% of squamous cell lung cancer. FCR with the dual side reading system is superior to the conventional screen-film system for visualization of nodular lung cancers. (author)

  1. Diagnostic accuracy of direct digital radiography and conventional radiography for proximal caries detection in primary teeth: A systematic review

    Directory of Open Access Journals (Sweden)

    Sivakumar Nuvvula

    2016-01-01

    Full Text Available Objective: The present study was conducted to uncover the diagnostic accuracy of digital versus conventional radiographic methods for the detection of proximal caries in primary teeth. Methods: Two researchers independently involved in the search process to explore Medical Subject Heading terms "dental digital radiography," "dental radiography," "bitewing," "dental caries," and "primary teeth" using PubMed, Cochrane Library, Ovid SP, and SIGLE databases. Search was confined to the articles published in English language only, with time period limit January 1996 to April 2014 and a hand search was performed to retrieve additional citations. Explicit inclusion and exclusion criteria were applied to eliminate undesired studies. Critical appraisal of the retrieved articles was done using the quality rating based on Bader and co-workers criteria. Results: A total of 129 articles were retrieved, among which 4 articles were included. All the four studies included were in vitro, of which two studies attained a high-quality score, whereas the other two attained average, and low scores based on Bader et al.′s criteria. Conclusions: A big lacuna exists in the literature, regarding the evaluation of radiographic systems in primary teeth, suggesting an immediate need for well conducted in vivo studies. The quality of available evidence can be regarded as fair but cannot be suggested to set a baseline, indicating a need to perform high-quality studies in a randomized sample to find out the accuracy of digital and conventional radiographs.

  2. Anwendungsbeobachtungen mit Zolmitriptan-Rapilmet in der Praxis

    Directory of Open Access Journals (Sweden)

    Wessely P

    2004-01-01

    Full Text Available Nach Darstellungen der Prinzipien der evidenzbasierten Therapie (EBM der Migräneattacken wird die besondere Bedeutung der Triptane hervorgehoben. Die Entscheidung, Triptane einzusetzen, wird nicht unter Anwendung einer starren stufenweisen Verordnung, sondern flexibel anhand von Entscheidungshilfen für eine stratifizierte Therapieplanung getroffen. Eine solche Hilfe ist z. B. der in den USA entwickelte MIDAS-Fragebogen, der übersichtlich und einfach den Gesamtkomplex der Migräne erfaßt und nicht nur den Kopfschmerz, sondern auch die begleitenden autonomen Phänomene und vor allem auch die Beeinträchtigungen im sozio-ökonomischen Formenkreis bewertet. Dadurch kann die individuell erforderliche Therapieintensität, also z. B. der Einsatz von Triptanen, einfacher abgeschätzt werden. Die vorliegende Studie ist eine offene Anwendungsbeobachtung von Zolmitriptan-Rapimelt bei 349 Migränepatienten unter Verwendung des MIDAS-Fragebogens. Nach dreimonatiger Therapie konnte eine globale Besserung im Bereich der MIDAS-Scores nachgewiesen werden, wobei der Schweregrad IV von 42,7 % auf 14,6 % abgenommen hat (insgesamt signifikant für die Verbesserung jeweils um einen MIDAS-Grad. Die Kopfschmerzfrequenz hat sich ebenfalls von 14,6 Kopfschmerztage auf 8,7 reduziert, ebenso die Intensität – gemessen auf einer VAS-Skala – von 7,3 auf 5,3. Die Nebenwirkungsrate lag unter 2 %, die subjektive Zufriedenheit mit der Gesamtwirksamkeit von Zolmitriptan-Lyotabletten wurde in der Beurteilung durch die Probanden von 49,9 % mit sehr gut und von 35,8 % als gut bewertet, lediglich 4,3 % befanden die Medikation als unzureichend. In der Behandlung von Migräneattacken läßt sich für Zolmitriptan-RM eine hohe Patientenakzeptanz und auch ein hohes Maß an Effektivität und Wirkkonsistenz nicht nur unter den strengen Kriterien einer klinischen Prüfung, sondern auch unter den Bedingungen der Alltagspraxis nachweisen.

  3. Dose audit for patients undergoing two common radiography examinations with digital radiology systems.

    Science.gov (United States)

    İnal, Tolga; Ataç, Gökçe

    2014-01-01

    We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.

  4. Systematic review of flexion/extension radiography of the cervical spine in trauma patients

    Energy Technology Data Exchange (ETDEWEB)

    Sierink, J.C., E-mail: j.c.sierink@amc.nl [Trauma Unit, Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Lieshout, W.A.M. van, E-mail: w.a.vanlieshout@amc.nl [Trauma Unit, Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Beenen, L.F.M., E-mail: l.f.beenen@amc.nl [Department of Radiology, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Schep, N.W.L., E-mail: n.w.schep@amc.nl [Trauma Unit, Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Vandertop, W.P., E-mail: w.p.vandertop@amc.nl [Neurosurgical Center Amsterdam, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Goslings, J.C., E-mail: j.c.goslings@amc.nl [Trauma Unit, Department of Surgery, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands)

    2013-06-15

    Introduction: The aim of this review was to investigate whether Flexion/Extension (F/E) radiography adds diagnostic value to CT or MRI in the detection of cervical spine ligamentous injury and/or clinically significant cervical spine instability of blunt trauma patients. Methods: A systematic search of literature was done in Pubmed, Embase and Cochrane Library databases. Primary outcome was sensitivity and specificity of F/E radiography. Secondary outcomes were the positive predicting value (PPV) and negative predicting value (NPV) (with CT or MRI as reference tests due to the heterogeneity of the included studies) of each modality and the quality of F/E radiography. Results: F/E radiography was overall regarded to be inferior to CT or MRI in the detection of ligamentous injury. This was reflected by the high specificity and NPV for CT with F/E as reference test (ranging from 97 to 100% and 99 to 100% respectively) and the ambiguous results for F/E radiography with MRI as its reference test (0–98% and 0–83% for specificity and NPV respectively). Image quality of F/E radiography was reported to have 31 to 70% adequacy, except in two studies which reported an adequacy of respectively 4 and 97%. Conclusion: This systematic review of the literature shows that F/E radiography adds little diagnostic value to the evaluation of blunt trauma patients compared to CT and MRI, especially in those cases where CT or MRI show no indication of ligamentous injury.

  5. SURVEY OF AWARENESS LEVELS OF DENTISTS ABOUT CORRECT USAGE OF VARIOUS RADIOGRAPHIES IN DENTISTRY

    Directory of Open Access Journals (Sweden)

    F Ezoddini Ardakani

    2007-07-01

    Full Text Available Introduction: With the increasing usage of X rays, professional responsibility entails dentists to have sufficient and correct knowledge about prescription of radiographies in order to correctly diagnose and minimally expose patients to radiation. The aim of this study was to assess the awareness levels of dentists in Yazd in term of correct prescription of radiographies. Method: In this descriptive, cross sectional study, specially formatted questionnaires were filled by 134 dentists. Their knowledge in 10 various fields for correct prescription of radiographies was evaluated and compared in each field on the basis of gender and educational status.(General, specialists Results: According to the results, knowledge levels about correct prescription of panoramic, periapical radiographies, CT and MRI was good, while that for occlussal radiographies, patients prone to caries, patients with periodontal diseases, evaluation of growth condition and dental crypts was moderate. In addition, it was weak for bitewing radiographies and in patients not prone to caries. There was no significant difference in awareness levels according to gender. The awareness level of specialists was much higher than that of general dentists except in cases of patients prone to caries where the difference was not significant. Conclusion: One of the most effective means for reducing probable risks of radiation is abstention from prescription of unnecessary radiographies.

  6. [Questions that radiography students have regarding X-ray photography: a qualitative study].

    Science.gov (United States)

    Terashita, Takayoshi; Kisa, Kengo; Oshima, Sumiko; Kawabata, Hidenobu

    2012-01-01

    To improve lectures and training programs on X-ray photography, we aimed to determine the questions that radiography students have regarding X-ray photography. We collected text data from questions on X-ray photography in radiography student reports after an X-ray photography training program. The text data were analyzed using content analysis. Codes were assigned to segments and they were categorized according to similarities. From 111 reports, 348 questions were collected. Four categories and 47 subcategories were obtained. The "Required Knowledge" category comprised subcategories concerning knowledge for the X-ray photography including X-ray radiography methodology and disease knowledge. The "Radiography Service" category comprised subcategories concerning radiographers' responsibilities in a hospital including the role of radiographer and the extent of responsibilities. The "Radiographers' Challenges" category comprised subcategories concerning unusual situations radiographers encounter at work including accurate positioning and communication with patients. The "Patient Types" category comprised subcategories concerning patients in whom X-ray photography was considered difficult including pediatric patients and patients with serious conditions. Questions related to subcategories in "Radiographers' Challenges" and "Patient Types" were interrelated. Radiography students had concerns regarding whether they would be able to handle difficult patients efficiently in clinical situations. We were able to suggest the re-orientation of radiography education according to students' intellectual appetite regarding X-ray radiography.

  7. Genotyp-/Phänotyp-Analyse und klinische Charakterisierung von 25 Familien mit familiärer Hypomagnesiämie mit Hyperkalziurie und Nephrokalzinose

    OpenAIRE

    Schneider, Linda

    2010-01-01

    Die familiäre Hypomagnesiämie mit Hyperkalziurie und Nephrokalzinose (FHHNC) ist eine autosomal rezessive renal-tubuläre Erkrankung, die häufig mit progredientem Nierenversagen assoziiert ist. Der primäre Defekt besteht in einer gestörten tubulären Reabsorption von Magnesium und Kalzium im dicken aufsteigenden Teil der Henle-Schleife (TAL) der Niere. Mutationen im CLDN16-Gen (früher PCLN1-Gen), welches für das renale Tight Junctio...

  8. Entwicklung und Evaluation eines psychoedukativen Elterngruppen-Trainingsprogramms für Familien mit autistischen Kindern

    OpenAIRE

    Probst, Paul

    2003-01-01

    In der Einleitung wird das Konzept des "Psychoedukativen Elterntrainings" erläutert und ein Überblick über den Forschungsstand zum Thema "Elterntraining in Familien mit autistischen Kindern" gegeben. Ausgehend von dieser Analyse wurde ein psychoedukatives Eltern-Gruppentraining für Familien mit autistischen Kindern entwickelt und im Rahmen eines 3-Monate-Follow-up-Versuchsplans evaluiert. Die beiden Hauptziele des Trainingcurriculums waren "Vermittlung eines Konzepts über Wesen, Ursach...

  9. Optische 3D-Messtechnik : Präzise Gestaltvermessung mit einem erweiterten Streifenprojektionsverfahren

    OpenAIRE

    Wiora, Georg

    2001-01-01

    Die Streifenprojektion mit zeitlich kodierten Beleuchtungsmustern hat sich nach ihrer Erfindung - trotz vorhandener Schwächen - schnell neben den, seit Jahrzehnten ausgereiften, mechanischen Koordinaten-Messmaschinen in der 3D-Messtechnik etabliert. Diese Arbeit stellt einen Beitrag zu ihrer Konsolidierung dar. Zur Abschätzung der Leistungsfähigkeit werden die Genauigkeitsgrenzen eines Streifenprojektionssystems mit einem neuen Ansatz theoretisch erfasst. Es wird ein Verfahren zur präzisen Be...

  10. Die Ferse schmerzt: Behandlung des M. triceps surae bei Patienten mit Fasciitis plantaris : Ein systematisches Literaturreview

    OpenAIRE

    Brunner, Melanie

    2015-01-01

    Darstellung des Themas: Die Dehnung des M. triceps surae bei Patienten mit Fasciitis plantaris wird in der Literatur als begleitende Intervention empfohlen. Dies lässt einen Zusammenhang zwischen den Plantarflexoren und den Fersenschmerzen vermuten, weshalb die Untersuchung von weiteren Behandlungsmethoden am M. triceps surae von Bedeutung ist. Ziel: Das Ziel dieser Arbeit war, eine Aussage über die Effektivität von verschiedenen Behandlungsmethoden des M. triceps surae bei Patienten mit F...

  11. trEATit - Intensive ambulante Gruppentherapie von Jugendlichen mit Essstörungen

    OpenAIRE

    Michler, Petra; Wolter-Flanz, Andrea; Linder, Martin

    2007-01-01

    Es wird ein intensives ambulantes Gruppentherapiekonzept für Mädchen mit Essstörungen (Anorexia nervosa, Bulimia nervosa, Binge-eating-disorder) vorgestellt, als Möglichkeit neben/statt der stationären Behandlung und der Einzeltherapie bei niedergelassenen Therapeuten. Das Therapiekonzept ist vorwiegend verhaltenstherapeutisch orientiert und fördert die Selbstmanagementfähigkeiten der Jugendlichen, selbstbestimmt und eigenverantwortlich mit ihrer Erkrankung umzugehen und...

  12. Biomechanische Untersuchungsergebnisse über die verbesserte Verankerung von Pedikelschrauben mit resorbierbarem

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Die Prim?rstabilit?t von Pedikelschrauben im Knochen h?ngt in hohem Masse von der Knochendichte ab. Die Augmentation mit Zement ist ein klinisch einsetzbares Verfahren, um die Schrauben-Verankerung im osteoporotischen Knochen zu verbessern.In dieser Studie wurde eine neuartiges resorbierbares Knochenersatzmaterial (α-BSMTM) für diese Augmentation benutzt. Biomechanische Testungen wurden in vitro bei 16 Lendwirbelkorpern (L3-L5) aus 6 Individuen(75,2±13,7 Jahre) durchgeführt. Vor der biomechanischen Testung wurde bei allen Pr?paraten die trabekul?re Knochendichte mittels pQCT gemessen und beide Pedikel mit USS-Pedikelschrauben (5,0 mm × 45 mm) besetzt, von welchen eine mit α-BSMTM augmentiert war. Beim axialen Auszugstest wurden die maximale axiale Auszugskraft (F-max) sowie die Energieaufnahme bestimmt. Der Medianwert der F-max stieg beim Auszugstest durch die Zementierung mit α-BSMTM um 80 % von 370 N (ohne Zement) auf 665 N (mit Zement). Die Energieaufnahme bis zum Erreichen der F-max (E-F-max) und bei Dislokation bis 2,0 mm (E-2 mm) steigerte sich ebenfalls um 83 % und 68 %. Die Unterschiede waren signifikant. (Wilcoxon′s-Test, P<0,01) Die Ausreisskrafte F-max (ohne oder mit Zement) korrelierten eng mit der Knochendichte (r=0,9056 und r=0,9585). Unsere Resultate zeigen, da eine Augmentation mit dem α-BSMTM die prim?re Stabilit?t von Pedikelschrauben verbessern kann. Der Effekt scheint auf einer Optimierung der Kontaktfl?che und einer Aussteifung der schraubennahen Spongiosa zu beruhen. Das Material konnte geeignet sein, die Verankerung von Pedikelschrauben bei osteoporotischen Patieten zu verbessern.

  13. Erfassung und Trainierbarkeit der posturalen Kontrolle und Modulation des Gangbildes bei Patienten mit Morbus Parkinson

    OpenAIRE

    2015-01-01

    Die vorliegende Arbeit gliedert sich in drei Teile. Zunächst geht es um die Erfassung der posturalen Instabilität bei Patienten mit Morbus Parkinson. Es wurde ein klinischer Gleichgewichtstest (Fullerton Advanced Balance (FAB) Scale) zur Erhebung der posturalen Kontrolle validiert und mit der Berg Balance Scale und dem Mini-Balance Evaluation System Test (Mini-BESTest) verglichen. Hierfür wurden 85 Parkinsonpatienten eingeschlossen und untersucht. Es konnte gezeigt werden, dass die FAB Sc...

  14. Analyse der T-Zellkreuzreaktivität bei Birkenpollenallergikern mit assoziierter Nahrungsmittelallergie

    OpenAIRE

    Hofmann, Claudia

    2014-01-01

    Eine Pollenallergie geht häufig mit einer sekundären Nahrungsmittelallergie einher, die durch die Kreuzreaktivität zwischen dem Pollen- und dem Nahrungsmittelallergen verursacht wird. In der vorliegenden Arbeit wurde eine Kohorte von 20 Allergikern mit einer Typ I-Allergie gegen Birkenpollen und einer assoziierten Nahrungsmittelallergie gegen Haselnüsse und/oder Karotten in Bezug auf eine allergenspezifische IgE-Antwort, T-Zellantwort und vor allen Dingen hinsichtlich der T-Zellkreuzreaktivit...

  15. Detection and Imaging of Moving Targets with LiMIT SAR Data

    Science.gov (United States)

    2017-03-03

    1 Detection and Imaging of Moving Targets with LiMIT SAR Data Michael Newey, Gerald Benitz, David Barrett MIT Lincoln Laboratory Lexington...sandeep.mishra@baesystems.com Abstract Detecting moving targets in SAR imagery has recently gained a lot of interest as a way to replace optical...moving target detection and classification in adverse (e.g. cloudy) weather conditions. This can be particularly important for small radar antennas

  16. Toess weir with small power station Pfungen; Toesswehr mit Kleinkraftwerk Pfungen

    Energy Technology Data Exchange (ETDEWEB)

    Haerri, R.W. [Amt fuer Gewaesserschutz und Wasserbau, Abt. Gewaesserkorrektionen, Zurich (Switzerland)

    1995-12-31

    Near Pfungen on the River Toess the Canton of Zurich replaced a dilapidated weir and utilises the available falling gradient with a small power station. Besides the production of renewable energy the assistance of a fish ladder has been made available. (orig.) [Deutsch] Bei Pfungen an der Toess ersetzte der Kanton Zuerich ein baufaelliges Wehr und nutzt das vorhandene Gefaelle mit einem Kleinkraftwerk. Neben der Erzeugung von erneuerbarer Energie kann nun mit Hilfe einer Treppe auch der Fischaufstieg gewaehrleistet werden. (orig.)

  17. Educational Outreach at the MIT Plasma Science and Fusion Center

    Science.gov (United States)

    Rivenberg, Paul; Thomas, Paul

    2006-10-01

    At the MIT PSFC, student and staff volunteers work together to increase the public's knowledge of fusion science and plasma technology. Seeking to generate excitement in young people about science and engineering, the PSFC hosts a number of educational outreach activities throughout the year, including Middle and High School Outreach Days. The PSFC also has an in-school science demonstration program on the theme of magnetism. The Mr. Magnet Program, headed by Mr. Paul Thomas, has been bringing lively demonstrations on magnetism into local elementary and middle schools for 15 years. This year Mr. Magnet presented the program to nearly 30,000 students at over 67 schools and other events, reaching kindergartners through college freshmen. In addition to his program on magnetism, he is offering an interactive lecture about plasma to high schools. The "Traveling Plasma Lab" encourages students to learn more about plasma science while having fun investigating plasma properties using actual laboratory techniques and equipment. Beyond the classroom, Paul Thomas has provided technical training for Boston Museum of Science staff in preparation for the opening of a Star Wars exhibit. His hands-on demos have also been filmed by the History Channel for a one-hour program about Magnetism, which aired in June 2006.

  18. Radiologic analysis of femoral acetabular impingement: from radiography to MRI

    Energy Technology Data Exchange (ETDEWEB)

    Dwek, Jerry R. [University of California at San Diego, Department of Radiology, Rady Children' s Hospital and Health Center, San Diego, CA (United States); San Diego Imaging, San Diego, CA (United States); Monazzam, Shafagh [Rady Children' s Hospital and Health Center, Department of Orthopedics, San Diego, CA (United States); Chung, Christine B. [University of California at San Diego, Department of Radiology, San Diego, CA (United States)

    2013-03-15

    Femoral acetabular impingement is a set of morphologic abnormalities that are considered to be a major cause of degenerative disease in the hip joint. Early changes are already present in adolescence when it is the pediatric radiologist who must assess current damage with the aim of averting progression to more severe and debilitating osteoarthritis. A multimodality approach is used for diagnosis, that includes conventional radiography and CT to assess the osseous structures. MR arthrography is the primary advanced imaging modality for assessment of morphologic changes as well as injuries of the labrum and articular cartilage. Details of radiologic imaging are offered to guide the radiologist and provide an avenue for the accurate description of the osseous and articular alterations and injury. (orig.)

  19. Inspection of an artificial heart by the neutron radiography technique

    CERN Document Server

    Pugliesi, R; Andrade, M L G; Menezes, M O; Pereira, M A S; Maizato, M J S

    1999-01-01

    The neutron radiography technique was employed to inspect an artificial heart prototype which is being developed to provide blood circulation for patients expecting heart transplant surgery. The radiographs have been obtained by the direct method with a gadolinium converter screen along with the double coated Kodak-AA emulsion film. The artificial heart consists of a flexible plastic membrane located inside a welded metallic cavity, which is employed for blood pumping purposes. The main objective of the present inspection was to identify possible damages in this plastic membrane, produced during the welding process of the metallic cavity. The obtained radiographs were digitized as well as analysed in a PC and the improved images clearly identify several damages in the plastic membrane, suggesting changes in the welding process.

  20. Case study: limitations of panoramic radiography in the anterior mandible.

    LENUS (Irish Health Repository)

    Walker, Cameron

    2009-12-01

    Dental Panoramic Tomography (DPT) is a widely used and valuable examination in dentistry. One area prone to artefacts and therefore misinterpretation is the anterior region of the mandible. This case study discusses a periapical radiolucency related to lower anterior teeth that is discovered to be a radiographic artefact. Possible causes of the artefact include a pronounced depression in the mental region of the mandible or superimposition of intervertebral spaces. Additional limitations of the DPT image include superimposition of radio-opaque structures, reduced image detail compared to intra-oral views and uneven magnification. These problems often make the DPT inappropriate for imaging the anterior mandible. Clinical Relevance: Panoramic radiography is often unsuitable for radiographic examination of the anterior mandible.

  1. The scrounge-atron: a proton radiography demonstration accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Alford, O J; Barnes, P D; Chargin, A K; Hartouni, E F; Hockman, J N; Moore, T L; Pico, R E; Ruggiero, A G

    1998-12-18

    The Scrounge-atron is a concept that could provide a demonstration accelerator for proton radiography. As discussed here, the Scrounge-atron would be capable of providing a 20 GeV beam of ten pulses, 10{sup 11} protons each, spaced 250 ns apart. This beam could be delivered once every minute to a single-axis radiographic station centered at the BEEF facility of the Nevada Test Site. These parameters would be sufficient to demonstrate, in five years, the capabilities of a proton-based Advanced Hydrotest Facility, and could return valuable information to the stockpile program, information that could not be obtained in any other way. The Scrounge-atron could be built in two to three years for $50-100 million. To meet this schedule and cost, the Scrounge-atron would rely heavily on the availability of components from the decommissioned Fermilab Main Ring.

  2. Scattering Correction For Image Reconstruction In Flash Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Liangzhi; Wang, Mengqi; Wu, Hongchun; Liu, Zhouyu; Cheng, Yuxiong; Zhang, Hongbo [Xi' an Jiaotong Univ., Xi' an (China)

    2013-08-15

    Scattered photons cause blurring and distortions in flash radiography, reducing the accuracy of image reconstruction significantly. The effect of the scattered photons is taken into account and an iterative deduction of the scattered photons is proposed to amend the scattering effect for image restoration. In order to deduct the scattering contribution, the flux of scattered photons is estimated as the sum of two components. The single scattered component is calculated accurately together with the uncollided flux along the characteristic ray, while the multiple scattered component is evaluated using correction coefficients pre-obtained from Monte Carlo simulations.The arbitrary geometry pretreatment and ray tracing are carried out based on the customization of AutoCAD. With the above model, an Iterative Procedure for image restORation code, IPOR, is developed. Numerical results demonstrate that the IPOR code is much more accurate than the direct reconstruction solution without scattering correction and it has a very high computational efficiency.

  3. Quantitative shadowgraphy and proton radiography for large intensity modulations

    CERN Document Server

    Kasim, Muhammad Firmansyah; Ratan, Naren; Sadler, James; Chen, Nicholas; Savert, Alexander; Trines, Raoul; Bingham, Robert; Burrows, Philip N; Kaluza, Malte C; Norreys, Peter

    2016-01-01

    Shadowgraphy is a technique widely used to diagnose objects or systems in various fields in physics and engineering. In shadowgraphy, an optical beam is deflected by the object and then the intensity modulation is captured on a screen placed some distance away. However, retrieving quantitative information from the shadowgrams themselves is a challenging task because of the non-linear nature of the process. Here, a novel method to retrieve quantitative information from shadowgrams, based on computational geometry, is presented for the first time. This process can be applied to proton radiography for electric and magnetic field diagnosis in high-energy-density plasmas and has been benchmarked using a toroidal magnetic field as the object, among others. It is shown that the method can accurately retrieve quantitative parameters with error bars less than 10%, even when caustics are present. The method is also shown to be robust enough to process real experimental results with simple pre- and post-processing techn...

  4. Dosimetry and image quality assessment in a direct radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Bruno Beraldo; Paixao, Lucas; Nogueira, Maria do Socorro, E-mail: boliveira.mg@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Oliveira, Marcio Alves de [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Fac. de Medicina. Dept. de Anatomia e Imagem; Teixeira, Maria Helena Araujo [Clinica Dra. Maria Helena Araujo Teixeira, Belo Horizonte, MG (Brazil)

    2014-11-15

    Objective: to evaluate the mean glandular dose with a solid state detector and the image quality in a direct radiography system, utilizing phantoms. Materials and methods: Irradiations were performed with automatic exposure control and polymethyl methacrylate slabs with different thicknesses to calculate glandular dose values. The image quality was evaluated by means of the structures visualized on the images of the phantoms. Results: considering the uncertainty of the measurements, the mean glandular dose results are in agreement with the values provided by the equipment and with internationally adopted reference levels. Results obtained from images of the phantoms were in agreement with the reference values. Conclusion: the present study contributes to verify the equipment conformity as regards dose values and image quality. (author)

  5. Diagnostic radiography of the shoulder. Die Roentgendiagnostik des Schulterguertels

    Energy Technology Data Exchange (ETDEWEB)

    Opitz, G.; Rechl, H. (Klinikum rechts der Isar, Muenchen (Germany, F.R.). Orthopaedische Klinik und Poliklinik); Lehner, K. (Klinikum rechts der Isar, Muenchen (Germany, F.R.). Inst. fuer Roentgendiagnostik)

    1989-06-01

    The frequent complaint about 'pain in the shoulder' is so diffuse that it needs exact clinical and differentiated radiographic examination. The diagnosis 'periarthritis humeroscapularis' can only be given after exclusion of ossous, chondral, or capsular lesions, joint disorders, rotator cuff rupture, or constriction of the subacromial space. Subsequent to antero-posterior and axial, sometimes also tangential, radiography, sonographic examination in many cases already yields the significant information. In case of suspected rotator cuff rupture, the diagnosis can be verified by arthrography or NMR imaging, and labrum defects can well be detected by computed arthro-tomography or NMR imaging. Although sometimes laborious, diagnostic radiology yields the information required to select the suitable conservative or surgical treatment. (orig.).

  6. Review and Prospect of Cobalt-60 Digital Radiography Inspection Technology

    Directory of Open Access Journals (Sweden)

    AN Ji-gang

    2015-11-01

    Full Text Available This article is a review and prospect of the research, development and industrialization of Cobalt-60 digital radiography inspection technology based on the national requirements in the recent 20 years, which is leaded by Institute of Nuclear and New Energy Technology (INET of TsinghuaUniversity. The research purpose, innovative approach and main academic achievements of this technology were described systematically. The industrial equipment varieties, performance, running condition and application effect were introduced, and the outstanding advantages and prospects of the technology are summarized. In the paper, some understanding obstacles or mistakes encountered during the promotion and application were sorted out and explained too to help the improvement and development of the new relevant technology.

  7. Ninety-nine years of radiation injuries in dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Maeda, Kadzuo (Nippon Dental Univ., Niigata (Japan). School of Dentistry at Niigata)

    1994-06-01

    A German dentist, F.O. Walkhoff, has started dental radiography as early as two weeks after Roentgen's discovery on November 8, 1895. The purpose of this paper is to revisit radiation injuries by dividing the era into the era of Kells (before World War II) and the era of low exposure doses (after World War II). Edmund Kells (1856-1928), a pioneer of dental radiologist in the United States, has later become a victim of radiation injuries. During the era of Kells, skin radiation injuries were frequent among the group of dental and medical personnels. In the era of low exposure doses, cancers, leukemia, and genetic effects have begun to receive attention. Radiation injuries occurring in a dental practice are discussed in the context of the two eras. (N.K.) 43 refs.

  8. NECTAR-A fission neutron radiography and tomography facility

    Energy Technology Data Exchange (ETDEWEB)

    Buecherl, T., E-mail: thomas.buecherl@radiochemie.de [Technische Universitaet Muenchen, Lehrstuhl fuer Radiochemie (RCM), Walther-Meissner-Str. 3, 85748 Garching (Germany); Lierse von Gostomski, Ch. [Technische Universitaet Muenchen, Lehrstuhl fuer Radiochemie (RCM), Walther-Meissner-Str. 3, 85748 Garching (Germany); Breitkreutz, H.; Jungwirth, M.; Wagner, F.M. [Technische Universitaet Muenchen, Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II) (Germany)

    2011-09-21

    NECTAR (Neutron Computerized Tomography and Radiography) is a versatile facility for radiographic and tomographic investigations as well as for neutron activation experiments using fission neutrons. The radiation sources for this facility are two plates of highly enriched uranium situated in the moderator vessel in FRM II. Thermal neutrons originating from the main fuel element of the reactor generate in these plates fast neutrons. These can escape through a horizontal beam tube without moderation. The beam can be filtered and manipulated in order to reduce the accompanying gamma radiation and to match the specific experimental tasks. A summary of the main parameters required for experimental set-up and (quantitative) data evaluation is presented. The (measured) spectra of the neutron and gamma radiations are shown along with the effect of different filters on their behavior. The neutron and gamma fluxes, dose rates, L/D-ratios, etc. and the main parameters of the actually used detection systems for neutron imaging are given, too.

  9. Chromatically Corrected Imaging Systems for Charged-Particle Radiography

    CERN Document Server

    Blind, Barbara

    2005-01-01

    In proton radiography, imaging with systems consisting of quadrupole magnets is an established technique for viewing the material distribution and composition of objects, either statically or during fast events such as explosions. With the most favorable magnet configuration, the -I lens, chromatic aberrations generally dominate the image blur. Image resolution can be improved, and largely decoupled from the input-beam parameters, by using a second-order achromatic bend with some additional higher-order aberration correction. The aberration-correction approach is discussed. For a given resolution, such a bend allows use of much lower-energy imaging particles than a -I lens. Each bend design represents a set of equivalent systems; an 800-MeV proton design and its equivalent 40-MeV electron system are presented. The electron system is useful for imaging small objects. Magnet errors in the achromatic bends must be tightly controlled to preserve image quality, but not beyond feasibility of present technology. Sys...

  10. Development of Interpretive Simulation Tool for the Proton Radiography Technique

    CERN Document Server

    Levy, M C; Wilks, S C; Ross, J S; Huntington, C M; Fiuza, F; Baring, M G; Park, H- S

    2014-01-01

    Proton radiography is a useful diagnostic of high energy density (HED) plasmas under active theoretical and experimental development. In this paper we describe a new simulation tool that interacts realistic laser-driven point-like proton sources with three dimensional electromagnetic fields of arbitrary strength and structure and synthesizes the associated high resolution proton radiograph. The present tool's numerical approach captures all relevant physics effects, including effects related to the formation of caustics. Electromagnetic fields can be imported from PIC or hydrodynamic codes in a streamlined fashion, and a library of electromagnetic field `primitives' is also provided. This latter capability allows users to add a primitive, modify the field strength, rotate a primitive, and so on, while quickly generating a high resolution radiograph at each step. In this way, our tool enables the user to deconstruct features in a radiograph and interpret them in connection to specific underlying electromagneti...

  11. Practical guidelines for radiographers to improve computed radiography image quality.

    Science.gov (United States)

    Pongnapang, N

    2005-10-01

    Computed Radiography (CR) has become a major digital imaging modality in a modern radiological department. CR system changes workflow from the conventional way of using film/screen by employing photostimulable phosphor plate technology. This results in the changing perspectives of technical, artefacts and quality control issues in radiology departments. Guidelines for better image quality in digital medical enterprise include professional guidelines for users and the quality control programme specifically designed to serve the best quality of clinical images. Radiographers who understand technological shift of the CR from conventional method can employ optimization of CR images. Proper anatomic collimation and exposure techniques for each radiographic projection are crucial steps in producing quality digital images. Matching image processing with specific anatomy is also important factor that radiographers should realise. Successful shift from conventional to fully digitised radiology department requires skilful radiographers who utilise the technology and a successful quality control program from teamwork in the department.

  12. Rethinking responsibility in radiography: Some ethical issues in South Africa

    Directory of Open Access Journals (Sweden)

    Harriet Rosanne Etheredge

    2011-02-01

    Full Text Available The field of radiography in South Africa is complex and presents a multitude of ethical issues. The discipline is often regarded as a supporting function in the healthcare chain, and a stepping-stone in the diagnostic process. This status of the discipline seems to have left many radiographers in a position of substantial confusion. In the course of numerous bioethics presentations for radiographers in South Africa, several ethical and legal issues have recurrently come to my attention. This article aims to address some of these issues and to offer ethically and legally acceptable solutions. The proposed solutions are not absolute – they are based on personal discussions and experiences – and their practicability needs to be scrutinised. Consequently, this article should be seen as a starting point only.

  13. Imaging Algorithms for Cosmic Ray Muon Radiography Detection of Nuclear Materials

    Institute of Scientific and Technical Information of China (English)

    LIU Yuanyuan; CHEN Zhiqiang; ZHAO Ziran; ZHANG Li; WANG Zhentian

    2009-01-01

    Cosmic ray muon radiography which has good penetration ability and is sensitive to high-Z mate-rials, is an effective method to detect shielded nuclear materials. This paper summarizes methods developed to process muon radiography in Tsinghua University. The methods include detector data correction, recon-struction algorithms (maximum likelihood scattering, MLS, and the maximum likelihood scattering and dis-placement, MLSD) acceleration, and the modification of the normalized mean absolute distance measure (NMADM) into a picture comparison binarization method (PCBM) which is more suitable for cosmic ray muon radiographs. Simulations demonstrate that all these methods give excellent results, so that cosmic muon radiography can become more widely used.

  14. Technical Specifications for the Neutron Radiography Facility (TRIGA Mark 1 Reactor). Revision 6

    Energy Technology Data Exchange (ETDEWEB)

    Tomlinson, R.L.; Perfect, J.F.

    1988-04-01

    These Technical Specifications state the limits under which the Neutron Radiography Facility, with its associated TRIGA Mark I Reactor, is operated by the Westinghouse Hanford Company for the US Department of Energy. These specifications cover operation of the Facility for the purpose of examination of specimens (including contained fissile material) by neutron radiography, for the irradiation of specimens in the pneumatic transfer system and approved in-core or in-pool irradiation facilities and operator training. The Final Safety Analysis Report (TC-344) and its supplements, and these Technical Specifications are the basic safety documents of the Neutron Radiography Facility.

  15. Single-exposure dual-energy computed radiography.

    Science.gov (United States)

    Stewart, B K; Huang, H K

    1990-01-01

    This paper focuses on analysis and development of a single-exposure dual-energy digital radiographic method using computed radiography (Fuji FCR-101 storage phosphor system). A detector sandwich consisting of storage phosphor imaging plates and an interdetector filter is used. The goal of this process is to provide a simple dual-energy method using typical plane-projection radiographic equipment and techniques. This approach exploits the transparency of the storage phosphor plates, using radiographic information that would be otherwise lost, to provide energy selective information essentially as a by-product of the radiographic examination. In order to effectively make use of the large dynamic range of the storage phosphor imaging plates (10,000:1), a computed radiography image reading mode of fixed analog-to-digital converter gain and variable photomultiplier sensitivity provides image data which can be related to relative incident exposure for export to the decomposition algorithm. Scatter rejection requirements necessitated crossed 12:1 grids for a field size of 36 x 36 cm. Optimal technique parameters obtained from computer simulation through minimization of the aluminum and Plexiglas equivalent image uncertainty under conditions of constant absorbed does resulted as: 100 kVp using a 0.15-mm-thick tin (Sn) interdetector filter for the lung field. This yields a surface exposure of 23 mR and a surface absorbed dose of 0.26 mGy for a 23-cm-thick chest. Clinical application in evaluation of the solitary pulmonary nodule is discussed, along with an image set demonstrating this application.

  16. Development of a system for neutron radiography and tomography

    Science.gov (United States)

    Mühlbauer, Martin J.; Calzada, Elbio; Schillinger, Burkhard

    2005-04-01

    Neutron radiography and tomography are getting more and more popular. Since they use the white thermal neutron spectrum, they are especially feasible even at small neutron sources, where the flux is too low for efficient scattering experiments requiring monochromatization of the beam. High-end tomography systems require the investment of several ten thousand Euros, with the costs often hindering the initiative for a new tomography setup. Based on the experiences gathered at Technische Universitaet Muenchen, we developed a cheaper system based on standard components that cannot compete with the sensitivity of a high-grade system, but is perfectly capable of doing neutron radiography and tomography. The system is meant as a startup construction kit for initiating tomography programs even at small neutron sources. The system is built from scratch, enabling the user to gain an understanding for the influence of each component on the image results. With the experience thus gained, he should be able to design his next and more advanced system by himself. To keep the whole system simple and cheap (the price should reach only a few percent of a high-end system), standard parts are used whenever possible, and all components are designed in such a way that they can be built without special equipment. Public domain and freeware software is used for data processing. Such a system is being built at FRM2 in Garching within the scope of a master thesis. After completion, a website will be installed with descriptions, diagrams and software for building and operating the system. Both hardware and software are discussed.

  17. The value of thyroid shielding in intraoral radiography

    Science.gov (United States)

    Hazenoot, Bart; Sanderink, Gerard C H; Berkhout, W Erwin R

    2016-01-01

    Objectives: To evaluate the utility of the application of a thyroid shield in intraoral radiography when using rectangular collimation. Methods: Experimental data were obtained by measuring the absorbed dose at the position of the thyroid gland in a RANDO® (The Phantom Laboratory, Salem, NY) male phantom with a dosemeter. Four protocols were tested: round collimation and rectangular collimation, both with and without thyroid shield. Five exposure positions were deployed: upper incisor (Isup), upper canine (Csup), upper premolar (Psup), upper molar (Msup) and posterior bitewing (BW). Exposures were made with 70 kV and 7 mA and were repeated 10 times. The exposure times were as recommended for the exposure positions for the respective collimator type by the manufacturer for digital imaging. The data were statistically analyzed with a three-way ANOVA test. Significance was set at p Isup, thyroid dose levels were comparable with both collimators at a level indicating primary beam exposure. Thyroid shield reduced this dose with circa 75%. For the Csup position, round collimation also revealed primary beam exposure, and thyroid shield yield was 70%. In Csup with rectangular collimation, the thyroid dose was reduced with a factor 4 compared with round collimation and thyroid shield yielded an additional 42% dose reduction. The thyroid dose levels for the Csup, Psup, Msup and BW exposures were lower with rectangular collimation without thyroid shield than with round collimation with thyroid shield. With rectangular collimation, the thyroid shield in Psup, Msup and BW reduced the dose 10% or less, where dose levels were already low, implying no clinical significance. Conclusions: For the exposures in the upper anterior region, thyroid shield results in an important dose reduction for the thyroid. For the other exposures, thyroid shield augments little to the reduction achieved by rectangular collimation. The use of thyroid shield is to be advised, when performing

  18. Multiscale image processing and antiscatter grids in digital radiography.

    Science.gov (United States)

    Lo, Winnie Y; Hornof, William J; Zwingenberger, Allison L; Robertson, Ian D

    2009-01-01

    Scatter radiation is a source of noise and results in decreased signal-to-noise ratio and thus decreased image quality in digital radiography. We determined subjectively whether a digitally processed image made without a grid would be of similar quality to an image made with a grid but without image processing. Additionally the effects of exposure dose and of a using a grid with digital radiography on overall image quality were studied. Thoracic and abdominal radiographs of five dogs of various sizes were made. Four acquisition techniques were included (1) with a grid, standard exposure dose, digital image processing; (2) without a grid, standard exposure dose, digital image processing; (3) without a grid, half the exposure dose, digital image processing; and (4) with a grid, standard exposure dose, no digital image processing (to mimic a film-screen radiograph). Full-size radiographs as well as magnified images of specific anatomic regions were generated. Nine reviewers rated the overall image quality subjectively using a five-point scale. All digitally processed radiographs had higher overall scores than nondigitally processed radiographs regardless of patient size, exposure dose, or use of a grid. The images made at half the exposure dose had a slightly lower quality than those made at full dose, but this was only statistically significant in magnified images. Using a grid with digital image processing led to a slight but statistically significant increase in overall quality when compared with digitally processed images made without a grid but whether this increase in quality is clinically significant is unknown.

  19. Fondaparinux bei Herz-Kreislauf-Erkrankungen: Ein neues Antithrombin mit herausragenden Eigenschaften

    Directory of Open Access Journals (Sweden)

    Huber K

    2008-01-01

    Full Text Available Fondaparinux, ein synthetisches Pentasaccharid, führt zu einer indirekten Hemmung des Gerinnungsfaktors Xa und behindert in der Folge die Bildung von Thrombin. Fondaparinux wurde als Vergleichssubstanz gegenüber unfraktioniertem (Standard- Heparin oder dem niedermolekularen Heparin Enoxaparin in der Prophylaxe oder Therapie von venösen Thrombosen getestet. Zuletzt wurde Fondaparinux auch bei Patienten mit akuten Koronarsyndromen (ACS untersucht: bei Patienten mit ACS ohne ST-Hebung (NSTE-ACS waren sowohl die Blutungsrate als auch die Kurz- und Langzeitmortalität im Fondaparinuxarm (2,5 mg/Tag s. c. signifikant geringer als in den Enoxaparin-behandelten Patienten (1 mg/kg KG 2×/Tag s. c. (OASIS-5-Studie. Bei Patienten mit akutem ST-Strecken-Hebungsinfarkt (STEMI war Fondaparinux in den Subgruppen der konservativ behandelten Patienten (ohne Reperfusion und der Patienten, die eine pharmakologische Reperfusion erhielten (Thrombolyse von Vorteil gegenüber Placebo oder unfraktioniertem Heparin. Hingegen zeigte sich bei Patienten mit STEMI, die einer Akut-PCI unterzogen wurden, eine starke Tendenz zugunsten von unfraktioniertem Heparin gegenüber Fondaparinux (OASIS-6-Studie. Daher wird Fondaparinux in den internationalen Richtlinien als das Antithrombin mit der günstigsten Risiko/Nutzen-Ratio bei NSTEMI aber auch bei STEMI-Patienten mit Ausnahme jener Patienten, die sich einer Akut-PCI unterziehen, empfohlen. Fondaparinux könnte schon in der nahen Zukunft die Heparine in diesen Indikationen weitgehend ersetzen.

  20. Comparison of conventional panoramic radiography and panoramic digital subtraction radiography in detection of simulated lesions of mandibular condyle

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2008-12-01

    Full Text Available "n  "nBackground and Aim: Digital subtraction Radiography (DSR is a method of accurate assessing condylar head changes. several studies have been carried out in applying DSR in dentistry, however there is a few number of studies in efficacy of DSR method in assesment of condylar head changes, The aim of this study was to compare panoramic radiography and DSR detecting simulated lesions of the mandibular condyl. "nMaterials and Methods: this was a process reaserch study, in which two dry human skulls with no obvious temporomandibular joint pathology were used. Osteophytic lesions were simulated using three sizes of bone chips that were placed on the medial portion of anterior and superolateral aspects of the condyle. Osteolytic lesions were simulated making 1 and 2 mm holes using round burr in the central portion of anterior aspect and Lateral pole of the condyle. Panoramic radiographs were prepared with and without the lesions in place. These paired radiographs were digitized and digital- subtraction images of the original panoramic images were obtained. Eight observers evaluated 155 images of each modality for the presence or absence and the type of simulated lesions of the mandibular condyle. Sensitivity, specificity, reliability and measure of agreement were analyzed using kappa test and crossed tables and qualitative variables were assess by chi-square and fisher's Exact test. "nResults: Specificity of panoramic and DSR methods were 15.4% and 66.7% respectively. Sensitivity of panoramic and DSR methods were 61.1% and 80.6% for osteophytic lesions and 37.5% and 83.3% for Osteolytic lesions. The percentage of correct decisions made in DSR method was significantly more than conventional panoramic method (82.6% vs 41.9% (p<0.0001. "nConclusion: Based on the results of this study digital subtraction technique was significantly more accurate than the panoramic radiographs in detection of simulated lesions of the mandibular condyle.

  1. Assessment and Comparison of Impacted Maxillary Canine Position in Panoramic Radiography with CBCT

    Directory of Open Access Journals (Sweden)

    F Ezoddiniardakani

    2015-05-01

    Conclusion: The study findings revealed that the angulation and magnification methods were not reliable in order to assess the impacted maxillary canines in panoramic radiography, though Angulation proved to be more successful than magnification method.

  2. Comparison study on CNR and SNR of thoracic spine lateral radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Won [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Min, Jung Whan; Lyu, Kwang Yeul [Dept. of Radiology, Shingu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Science, College of Health Science, Korea University, Seoul (Korea, Republic of); Jeong, Hei Woun [Dept. of Radiological Science, Beakseok Culture University, Cheonan (Korea, Republic of); Lee, Joo Ah [Dept. of Oncology, Catholic University of Korea Incheon St.Mary,s Hospital, Incheon (Korea, Republic of); Jung, Jae Hong [Dept. of Oncology, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Sung, Dong Chan [Dept. of Radiology, Dong Guk University Medical Center, Seoul (Korea, Republic of); Park, Soon Cheol [Dept. of Radiology, Kang Dong Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2013-12-15

    This study was proven for the T-spine breathing technique in lateral projection, using computer radiography (CR), charge coupled device (CCD), indirect digital radiography (IDR) and direct digital radiography (DDR). All images were evaluated and compared with CNR and SNR measured with the mean pixels and the standard deviation as setting ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk using Image J. In experiment results of 4 type detectors, T-spine breathing technique was indicated as excellent in ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk. As T-spine breathing technique indicated excellent images compared to the existing T-spine lateral radiography, this method would be useful for elderly patients who have difficulty in deep exhalation. This study was indicated the application possibility of T-spine breathing technique by presenting contrast to noise ratio (CNR) and signal to noise ratio (SNR) with quantitative value in 4 type detectors.

  3. Development of the neutron radiography facility and its installation in HANARO

    CERN Document Server

    Nam, K Y; Kim, H J; Kim, Y K; Lee, C H; Lim, I C; Sim, C M

    2001-01-01

    HANARO neutron radiography facility has been developed to do industrial and scientific research and developments. Characterization and detailed evaluation of the NRF system after its development are indispensible information to research and application by using the system. This report is based on the results from the neutron radiography facility, installation works for the last several years from 1994 to 1997 and characterization work thereafter. This report describes the principle of neutron radiography, theoretical aspects in several parts, overall introduction of the HANARO neutron radiography facility, and discussions in each characteristics in detail. As key components of the NRF, in-pile collimator, Bi filter, L/D ratio, thermal neutron flux and its distribution in radiation active area were studied and described. In addition to these parts, several minor parts and auxiliary aspects were also mentioned. The imaging methods and characteristics in each one are described shortly and categorized, and a prot...

  4. The application and development of radiography technology based on x-ray

    Science.gov (United States)

    Chen, Hao; Xu, Zhou; Li, Ming

    2009-07-01

    Modern Radiography technology was combined with radiation physics and modern imaging processing, which was an important branch of information obtainment and processing. We can get the inside information of the object, by the X ray's attenuation when the ray penetrated the object, and depending on the computer's fast processing, we can see the slice imaging of the object. Computerized Tomography, Computerized Laminography, and Digital Radiography were important parts in Radiography. The institute of applied electronics, CAEP in the research of intense radiation had developed several advanced radiation sources and some advanced radiography imaging systems, for example, S-band small spot linear accelerator, full solid state modulator, C-band linear accelerator, high energy Tera-hertz radiation source and CT technology based on cone beam, DR technology, CL Technology etc. Such imaging systems had been applied in industrial NDT/NDE, security check, medical diagnosis, petroleum and gas pipeline inspection system etc.

  5. FMEA Based Risk Assessment of Component Failure Modes in Industrial Radiography

    CERN Document Server

    Pandey, Alok; Sonawane, A U; Rawat, Prashant S

    2016-01-01

    Industrial radiography has its inimitable role in non-destructive examinations. Industrial radiography devices, consisting of significantly high activity of the radioisotopes, are operated manually by remotely held control unit. Malfunctioning of these devices may cause potential exposure to the operator and nearby public, and thus should be practiced under a systematic risk control. To ensure the radiation safety, proactive risk assessment should be implemented. Risk assessment in industrial radiography using the Failure Modes & Effect Analysis (FMEA) for the design and operation of industrial radiography exposure devices has been carried out in this study. Total 56 component failure modes were identified and Risk Priority Numbers (RPNs) were assigned by the FMEA expert team, based on the field experience and reported failure data of various components. Results shows all the identified failure modes have RPN in the range of 04 to 216 and most of the higher RPN are due to low detectability and high severi...

  6. Verantwortlicher Umgang mit Antibiotika: Notwendigkeit der Antibiotikareduktion in der Aknetherapie.

    Science.gov (United States)

    Gollnick, Harald P M; Buer, Jan; Beissert, Stefan; Sunderkätter, Cord

    2016-12-01

    Der übermäßige oder unkritische weltweite Einsatz von Antibiotika in der Medizin hat die Ausbreitung von Antibiotikaresistenzen beschleunigt. In einigen Bereichen sind viele Antibiotika bei bakteriellen Infektionen, die zuvor noch gut auf antibakterielle Wirkstoffe reagierten, mittlerweile wirkungslos geworden. Dermatologen/Venerologen setzten orale und topische Antibiotika bei der Behandlung von Acne vulgaris routinemäßig ein, obwohl Akne weder eine infektiöse Erkrankung ist noch alleine durch das Propionibacterium getriggert wird. Vielmehr ist sie eine komplexe, chronische entzündliche Hauterkrankung, die durch verschiedene pathogenetische Faktoren wie follikuläre Hyperkeratose, erhöhter Sebumproduktion, bakterielle Proliferation und Entzündung zustande kommt. Folglich sollte eine erfolgreiche Therapie auf die Bekämpfung verschiedener pathogenetischer Faktoren und nicht nur auf die von Propionibacterium acnes abzielen. Daher wurden topische Retinoide und Benzoylperoxid als Mittel der ersten Wahl definiert. Monotherapien mit lokalen Antibiotika sollten insgesamt vermieden werden. Systemische Antibiotika der Tetrazyklin-Gruppe haben bei bestimmen Krankheitsstadien ihren Sinn, ihre Wirkung könnte aber eher auf der antientzündlichen als auf der antibiotischen Reaktion beruhen. Gesundheitsbehörden ermahnen alle Gesundheitsdienstleister, den Einsatz von Antibiotika einzuschränken. Das Nutzen-Risiko-Verhältnis muss bei der Entscheidung für oder gegen eine antibiotische Therapie bei einem einzelnen Patienten immer auch in Bezug auf das öffentliche Interesse am Erhalt der Wirksamkeit von Antibiotika abgewogen werden. Im Folgenden werden das aktuelle Krankheitskonzept zu Acne vulgaris und die sich daraus ableitenden Konsequenzen für den Einsatz von Antibiotika vorgestellt. © 2016 Deutsche Dermatologische Gesellschaft (DDG). Published by John Wiley & Sons Ltd.

  7. Mit Bourdieu in die Stadt: Relevanz, Prinzipien, Anwendungen

    Directory of Open Access Journals (Sweden)

    Loïc Wacquant

    2017-06-01

    Full Text Available Dieser Beitrag zeigt die Relevanz der Soziologie Bourdieus für die Stadtforschung auf, indem er Bourdieus Frühwerk zu Macht, Raum und Urbanisierung im Béarn und Algerien aufgreift und es mit seinem Spätwerk verknüpft, in welchem er das soziale Leiden in der französischen Metropole analysiert. Es wirft ein Schlaglicht auf die vier übergreifenden Prinzipien, die Bourdieus Forschungspraxis antreiben und eine fruchtbare Anleitung für die Stadtforschung sein können: den Bachelardschen Imperativ des erkenntnistheoretischen Bruchs und der erkenntnistheoretischen Wachsamkeit; die Webersche Aufforderung zur dreifachen Historisierung des Handelnden (Habitus, der Welt (sozialer Raum, wovon das soziale Feld lediglich einen Untertypus darstellt und der Kategorien des Analytikers (erkenntnistheoretische Reflexivität; den Leibnizschen-Durkheimschen Vorschlag, eine topologische Denkweise zu nutzen, um den Wechselbeziehungen zwischen symbolischem, sozialem und physischem Raum nachzuspüren; sowie das Cassirersche Moment, das uns dazu anhält, die konstitutive Wirksamkeit symbolischer Strukturen zur Kenntnis zu nehmen. Ich möchte zudem auf drei Fallstricke hinweisen, die eine Stadtforschung auf den Spuren Bourdieus tunlichst vermeiden sollte: die Fetischisierung von Konzepten; die Verlockung, sich der Sprache Bourdieus zu bedienen („speaking Bourdieuse“, ohne die Forschungsschritte, die die Bourdieuschen Begriffe verlangen, tatsächlich durchzuführen; sowie das zwanghafte Überstülpen seines Theorierahmens als Ganzes auch in Fällen, in denen es produktiver wäre, einzelne Bausteine zu übertragen.

  8. A survey of digital radiography practice in four South African teaching hospitals: an illuminative study

    Science.gov (United States)

    Nyathi, T; Chirwa, TF; van der Merwe, DG

    2010-01-01

    Purpose: The purpose of this study was to assess radiographer familiarity and preferences with digital radiography in four teaching hospitals and thereafter make recommendations in line with the migration from screen film to digital radiography. Materials and methods: A questionnaire was designed to collect data from either qualified or student radiographers from four teaching hospitals. From the four teaching hospitals, there were a total of 205 potential respondents. Among other things, responses regarding experiences and preferences with digital radiography, quality control procedures, patient dose, advantages and disadvantages of digital radiography were sought. The information collected was based on self-reporting by the participants. The study is exploratory in nature and descriptive statistics were generated from the collected data using Microsoft Excel 2007 and StatsDirect software. Results: Sixty-three out of 205 (31%) radiographers from all the four radiology centers responded to the circulated questionnaire. Only 15% (8) of the qualified radiographers had 4 or more years of experience with digital radiography compared to 68% (36) for the same amount of experience with screen-film radiography. Sixty-one percent (38) of the participants had been exposed to digital radiography during their lectures while at university. A small proportion, 16% (10) of the respondents underwent formal training in quality control procedures on the digital X-ray units they were using. Slightly more than half (55%) of the participants felt it was easier for them to retake an image in digital radiography than in screen film radiography. Conclusion: The results of this survey showed that the participants are familiar with digital radiography and have embraced this relatively new technology as shown by the fact that they can identify both its advantages and disadvantages as applied to clinical practice. However, there are minimal quality control procedures specific to digital

  9. Inspection of CF188 composite flight control surfaces with neutron radiography

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, W.J.; Bennett, L.G.I. [Royal Military Coll. of Canada, Kingston, Ontario (Canada). Dept. of Chemistry and Chemical Engineering; Mullin, S.K. [Aerospace and Telecommunications Engineering Support Squadron, Astra, Ontario (Canada). Nondestructive Testing Center Development Section

    1996-12-31

    At the Royal Military College of Canada`s SLOWPOKE-2 Facility, a neutron radiography facility has been designed and installed using a small (20kWth), pool-type research reactor called the SLOWPOKE-2 (Safe Low Power c(K)ritical Experiment) as the neutron source. Since then, the research has continued along two fronts: developing applications and improving the quality of the neutron beam. The most interesting applications investigated to date has been the inspection of various metal ceramic composites and the inspection of the composite flight control surfaces of some of the CF188 Hornet aircraft. As part of the determination of the integrity of the aircraft, it was decided to inspect an aircraft with the highest flight house using both X- and neutron radiography. The neutron radiography and, to a lesser extent, X-radiography inspections completed at McClellan AFB revealed 93 anomalies. After returning to Canada, the component with the greatest structural significance, namely the right hand rudder from the vertical stabilizer, was removed from the aircraft and put through a rigorous program of numerous NDT inspections, including X-radiography (film and real-time), eddy current, ultrasonics (through transmission and pitch-catch), infrared thermography, and neutron radiography. Therefore, of all the techniques investigated, only through transmission ultrasonics and neutron radiography were able to identify large areas of hydration. However, only neutron radiography could identify the small areas of moisture and hydration. Given the structural significance of the flight control surfaces in modern fighter aircraft, even the smallest amounts of hydration could potentially lead to catastrophic results.

  10. Interpretation of Core Length in Shear Coaxial Rocket Injectors from X-ray Radiography Measurements

    Science.gov (United States)

    2014-06-01

    Shear Coaxial Rocket Injectors from X-ray Radiography Measurements 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT...ASME/SAE/ASEE Joint Propulsion Conference, Cleveland, OH, 28-30 July, 2014. PA#14340 14. ABSTRACT Shear coaxial injectors are so named because they...Length in Shear Coaxial Rocket Injectors from X-ray Radiography Measurements S. Alexander Schumaker1, Stephen A. Danczyk2 and Malissa D.A. Lightfoot2

  11. A Review of Full-Body Radiography in Nontraumatic Emergency Medicine

    OpenAIRE

    2012-01-01

    This paper reports on the application of full-body radiography to nontraumatic emergency situations. The Lodox Statscan is an X-ray machine capable of imaging the entire body in 13 seconds using linear slit scanning radiography (LSSR). Nontraumatic emergency applications in ventriculoperitoneal (VP) shunt visualisation, emergency room arteriography (ERA), detection of foreign bodies, and paediatric emergency imaging are presented. Reports show that the fast, full-body, and low-dose scanning c...

  12. A review of full-body radiography in nontraumatic emergency medicine

    OpenAIRE

    2012-01-01

    This paper reports on the application of full-body radiography to nontraumatic emergency situations. The Lodox Statscan is an X-ray machine capable of imaging the entire body in 13 seconds using linear slit scanning radiography (LSSR). Nontraumatic emergency applications in ventriculoperitoneal (VP) shunt visualisation, emergency room arteriography (ERA), detection of foreign bodies, and paediatric emergency imaging are presented. Reports show that the fast, full-body, and low-dose scanning c...

  13. Design of a mobile neutron radiography installation based on a compact sealed tube neutron generator

    Institute of Scientific and Technical Information of China (English)

    MaWei-Chao; YaoAn-Ju; 等

    1997-01-01

    A series of optimum conditions are taken into account in the construction of neutron radiography(NR) installation based on a sealed tube neutron generator capable of gnerating 1010 n/s with 14MeV.The characteristics of NNU screens,a kind of self-made 6LiF.ZnS(Ag)scintillation intensifying screen are presented.Finally,some neutron radiographies taken by this NR installation and NNU screens are given.

  14. Observer variation for radiography, computed tomography, and magnetic resonance imaging of occult hip fractures

    Energy Technology Data Exchange (ETDEWEB)

    Collin, David; Dunker, Dennis; Goethlin, Jan H (Dept. of Radiology, Sahlgrenska Univ. Hospital, Moelndal (Sweden)), email: david.collin@vgregion.se; Geijer, Mats (Center for Medical Imaging and Physiology, Skaane Univ. Hospital, Lund Univ., Lund (Sweden))

    2011-10-15

    Background Conventional radiography is insufficient for diagnosis in a small but not unimportant number of hip fractures, and secondary imaging with computed tomography (CT) or magnetic resonance imaging (MRI) is warranted. There are no convincing observer variation studies performed for conventional radiography or CT in occult fractures, and no large materials for MRI. Purpose To assess observer variation in radiography, CT and MRI of suspected occult, non-displaced hip fractures, and to evaluate to what extent observer experience or patient age may influence observer performance. Material and Methods A total of 375 patients after hip trauma where radiography was followed by CT or MRI to evaluate a suspected occult hip fracture were collected retrospectively from two imaging centers. After scoring by three observers with varying degrees of radiologic experience, observer variation was assessed by using linear weighted kappa statistics. Results For radiography, agreements between the three observers were moderate to substantial for intra capsular fractures, with kappa values in the ranges of 0.56-0.66. Kappa values were substantial for extracapsular fractures, in the ranges of 0.69-0.72. With increasing professional experience, fewer fractures were classified as equivocal at radiography. For CT and MRI, observer agreements were similar and almost perfect, with kappa values in the ranges of 0.85-0.97 and 0.93-0.97. Conclusion There were almost perfect observer agreements for CT and MRI in diagnosing non-displaced, occult hip fractures. Observer agreements for radiography were moderate to substantial, and observer experience influenced agreement only at radiography

  15. Neutron Radiography Facility at IBR-2 High Flux Pulsed Reactor: First Results

    Science.gov (United States)

    Kozlenko, D. P.; Kichanov, S. E.; Lukin, E. V.; Rutkauskas, A. V.; Bokuchava, G. D.; Savenko, B. N.; Pakhnevich, A. V.; Rozanov, A. Yu.

    A neutron radiography and tomography facilityhave been developed recently at the IBR-2 high flux pulsed reactor. The facility is operated with the CCD-camera based detector having maximal field of view of 20x20 cm, and the L/D ratio can be varied in the range 200 - 2000. The first results of the radiography and tomography experiments with industrial materials and products, paleontological and geophysical objects, meteorites, are presented.

  16. Knocking down mitochondrial iron transporter (MIT) reprograms primary and secondary metabolism in rice plants.

    Science.gov (United States)

    Vigani, Gianpiero; Bashir, Khurram; Ishimaru, Yasuhiro; Lehmann, Martin; Casiraghi, Fabio Marco; Nakanishi, Hiromi; Seki, Motoaki; Geigenberger, Peter; Zocchi, Graziano; Nishizawa, Naoko K

    2016-03-01

    Iron (Fe) is an essential micronutrient for plant growth and development, and its reduced bioavailability strongly impairs mitochondrial functionality. In this work, the metabolic adjustment in the rice (Oryza sativa) mitochondrial Fe transporter knockdown mutant (mit-2) was analysed. Biochemical characterization of purified mitochondria from rice roots showed alteration in the respiratory chain of mit-2 compared with wild-type (WT) plants. In particular, proteins belonging to the type II alternative NAD(P)H dehydrogenases accumulated strongly in mit-2 plants, indicating that alternative pathways were activated to keep the respiratory chain working. Additionally, large-scale changes in the transcriptome and metabolome were observed in mit-2 rice plants. In particular, a strong alteration (up-/down-regulation) in the expression of genes encoding enzymes of both primary and secondary metabolism was found in mutant plants. This was reflected by changes in the metabolic profiles in both roots and shoots of mit-2 plants. Significant alterations in the levels of amino acids belonging to the aspartic acid-related pathways (aspartic acid, lysine, and threonine in roots, and aspartic acid and ornithine in shoots) were found that are strictly connected to the Krebs cycle. Furthermore, some metabolites (e.g. pyruvic acid, fumaric acid, ornithine, and oligosaccharides of the raffinose family) accumulated only in the shoot of mit-2 plants, indicating possible hypoxic responses. These findings suggest that the induction of local Fe deficiency in the mitochondrial compartment of mit-2 plants differentially affects the transcript as well as the metabolic profiles in root and shoot tissues. © The Author 2015. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  17. A transportable neutron radiography system based on a SbBe neutron source

    Science.gov (United States)

    Fantidis, J. G.; Nicolaou, G. E.; Tsagas, N. F.

    2009-07-01

    A transportable neutron radiography system, incorporating a SbBe neutron source, has been simulated using the MCNPX code. Design provisions have allowed two radiography systems to be utilised using the same SbBe neutron source. In this respect, neutron radiographies can be carried out using the photoneutrons produced when the 124Sb is surrounded by the Be target. Alternatively, γ-radiography can be utilised with the photons from the 124Sb with the target removed. Appropriate collimators were simulated for each of the radiography modes. Apart from Be, the materials considered were compatible with the European Union Directive on 'Restriction of Hazardous Substances' (RoHS) 2002/95/EC, hence excluding the use of cadmium and lead. Bismuth was chosen as the material for γ-radiation shielding and the proposed system allowed a maximum activity of the 124Sb up to 1.85×1013 Bq. The system simulated allows different object sizes to be studied with a wide range of radiography parameters.

  18. An experimental comparative study of radiography, ultrasonography and CT imaging in the IV catheter fragment

    Energy Technology Data Exchange (ETDEWEB)

    Kweon, Dae Cheol [Dept. of Radiological Science, College of Health Science, Shinhan University, Uijeongbu (Korea, Republic of)

    2016-06-15

    The objective of this study was to detect the fragments generated during IV (intravenous) catheter injection of contrast medium and drug administration in a clinical setting and removal was performed by experimentally producing a phantom, and to compare the radiography, ultrasonography, and multi-detector computed tomography (MDCT) imaging and radiation dose. A 1 cm fragment of an 18 gage Teflon® IV catheter with saline was inserted into the IV control line. Radiography, CT, and ultrasonography were performed and radiography and CT dose were calculated. CT and ultrasonography showed an IV catheter fragment clinically and radiography showed no visible difference in the ability to provide a useful image of an IV catheter fragment modality (p >.05). Radiography of effective dose (0.2139 mSv·Gy-1·cm-2) form DAP DAP (0.93 μGy·m2 ), and dose length product (DLP) (201 mGy·cm) to effective dose was calculated as 0.483 mSv. IV catheter fragment were detected of radiography, ultrasonography and CT. These results can be obtained by menas of an excellent IV catheter fragment of detection capability CT. However, CT is followed by radiation exposure. IV catheter fragment confirming the position and information recommend an ultrasonography.

  19. Twenty-degree-tilt radiography for evaluation of lateral humeral condylar fracture in children

    Energy Technology Data Exchange (ETDEWEB)

    Imada, Hideaki; Tanaka, Ryuji; Itoh, Yohei; Kishi, Kazuhiko [National Hospital Organization, Higashi-Hiroshima Medical Center, Department of Orthopedic Surgery, Higashi Hiroshima, Hiroshima (Japan)

    2010-03-15

    To investigate the efficacy of '20 -tilt anteroposterior (A-P) radiography' in the assessment of lateral condylar fractures of the distal humerus. Eighteen children with lateral humeral condylar fractures were studied. Every child underwent conventional A-P and lateral radiography, and six children underwent multi-detector computed tomography (MDCT). For the investigation of 20 -tilt radiography, ten children with lateral humeral condylar fractures had conventional and 20 -tilt A-P and lateral radiography both preoperatively and postoperatively. Fragment dislocation was measured at the lateral and medial margins of the fracture on both the conventional A-P and 20 -tilt A-P radiographs. The lateral condylar fragment was triangular and was most prominent posteriorly. The fracture line was typically tilted approximately 20 to a reference line perpendicular to the long axis of the humerus in the lateral view. The extent of dislocation at the lateral and medial margins of the fracture site by 20 -tilt A-P radiography (9.3 {+-} 3.6 mm and 5.6 {+-} 2.5 mm) was significantly wider than that measured by the conventional method (6.8 {+-} 4.1 mm and 2.0 {+-} 1.5 mm), which may influence treatment. Twenty-degree-tilt A-P radiography may more precisely demonstrate fragment dislocation than standard radiographs and may influence patient treatment. (orig.)

  20. Whole-body MRI of Langerhans cell histiocytosis: comparison with radiography and bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo; Yang, Dong Hyun [Asan Medical Center, Department of Radiology, University of Ulsan College of Medicine, Seoul (Korea); Ra, Young Shin [Asan Medical Center, Department of Neurosurgery, University of Ulsan College of Medicine, Seoul (Korea); Song, Joon Sup; Im, Ho Joon; Seo, Jong Jin; Ghim, Thad; Moon, Hyung Nam [Asan Medical Center, Department of Pediatric Oncology, University of Ulsan College of Medicine, Seoul (Korea)

    2006-10-15

    In Langerhans cell histiocytosis (LCH) evaluation of the extent of disease is one of the major predictors of patient outcome. Historically this is undertaken using plain radiography and bone scintigraphy. Recently, whole-body (WB) MRI has been reported to be useful in detecting skeletal and extraskeletal metastases in both adults and children. To evaluate the usefulness of WB MRI in patients with LCH in comparison with plain radiography and bone scintigraphy. In nine children (1-7 years of age; mean 3.3 years) who had a pathological diagnosis of LCH and had either plain radiography or bone scintigraphy for comparison, 43 WB MR examinations were performed. Skeletal and extraskeletal lesions of the disease on WB MRI were compared with those on plain radiography and bone scintigraphy. LCH showed unifocal single-system involvement in one patient, multifocal single-system involvement in three, and multifocal multisystem disease in five. WB MRI identified additional skeletal lesions in three (38%) of eight patients, compared with plain radiography, and in two (25%) of eight, compared with bone scintigraphy. WB MRI detected extraskeletal lesions of the disease in five (56%) of the nine patients exclusively, except for one patient whose lung lesions were also detected on plain radiography. In two patients, treatment was changed according to WB MRI findings. (orig.)

  1. Kasuistik 2: 54-jähriger LKW-Fernfahrer mit Verdacht auf Schilddrüsenunterfunktion

    Directory of Open Access Journals (Sweden)

    Jockenhövel F

    2003-01-01

    Full Text Available 54-jähriger LKW-Fernfahrer mit Leistungsschwäche, Rückenschmerzen, erektiler Dysfunktion, vermehrter Müdigkeit. Wird vom Hausarzt mit der Frage einer eventuellen Schilddrüsenunterfunktion (Hypothyreose vorgestellt. Keine relevanten Vorerkrankungen, gelegentlich Voltaren als Medikation gegen Rückenschmerzen. Auf Befragen erektile Dysfunktion mit mangelnder Rigidität zur Emission, bzw. zu schnellem Verlust der Rigidität.

  2. Abdichtung von fließfettgeschmierten Getrieben mit Radialwellendichtungen - Reibungsminderung durch Makrostrukturierung der Dichtungsgegenlauffläche

    OpenAIRE

    2014-01-01

    Diese Arbeit befasst sich mit Radialwellendichtungen von fließfettgeschmierten Getrieben und den Einflüssen der einzelnen Komponenten des Dichtsystems auf dessen Funktion und Verschleiß. Verglichen mit ölgeschmierten Systemen ist der Schmierstoffaustausch in fließfettgeschmierten Getrieben deutlich geringer. Hohe Dichtsystemtemperaturen bis hin zu globaler Mangelschmierung sind die Folgen. Anhand eines praxisnahen Experimentalgetriebes mit einem Wellendurchmesser von 50mm erfolgt eine systema...

  3. “Die Lexik mit dem semantischen Merkmal ‚Emotionalität’ der deutschen und der makedonischen Gegenwartssprache“

    OpenAIRE

    Ivanovska, Biljana

    2005-01-01

    Im Mittelpunkt dieses Beitrags steht die Zusammenfassung der Doktorarbeit: “Die Lexik mit dem semantischen Merkmal ‚Emotionalität’ der deutschen und der makedonischen Gegenwartssprache“ und die Untersuchung der emotional wertenden Lexik beider Sprachsysteme mit einem kontrastiven Sprachvergleich. “Die Lexik mit dem semantischen Merkmal ‚Emotionalität’ der deutschen und der makedonischen Gegewartssprache“ wird als Doktorarbeit an der Philologischen Fakultät „Blaze Koneski“ in Skopje verteidigt...

  4. Behandlung psychotischer Störungen - Aspekte der Therapiebeziehung und Untersuchung unmedizierter Menschen mit psychotischen Störungen

    OpenAIRE

    2015-01-01

    Die vorliegende kumulative Dissertation befasst sich mit der Behandlung psychotischer Störungen und setzt sich aus drei Studien zusammen. Dabei werden mit dem Fokus auf Therapieprozesse im Rahmen der Kognitiven Verhaltenstherapie für Psychosen (Studien 1 und 2) sowie auf die spezifische Gruppe der unmedizierten Personen mit psychotischen Störungen (Studie 3) zwei inhaltliche Schwerpunkte gesetzt. Die therapeutische Beziehung in de...

  5. Diagnosis of Nasopharyngeal Obstruction by Lateral Cephalometric Radiography

    Directory of Open Access Journals (Sweden)

    H. Ravanmehr

    2005-06-01

    Full Text Available Statement of Problem: Nasopharyngeal obstruction by adenoid enlargement is one of the main causes of mouth breathing. Diagnostic indices of nasopharyngeal obstruction by lateral cephalometric radiography are controversial.Purpose: The purpose of this study was to diagnose the nasopharyngeal obstruction by means of lateral cephalometric radiography.Materials and Methods: In this research two groups, (study and control, of 6 to 15 years old were studied. In the study group, 46 mouth breathers were clinically examined by an orthodontist and an Otolaryngologist to confirm the nasopharyngeal obstruction.Control group was also comprised of 46 nasal breathers within the same age groups. A lateral cephalogram in centric occlusion was obtained for each patient. After tracing,following 7 nasopharyngeal variables were measured: 1- pp (palatopharyngeal depth.2- Ad.Pmp (nasopharyngeal airway depth. 3- Air area (nasopharyngeal airway area. 4-NP area (bony area of nasopharynx. 5- Ba.Pmp (bony depth of nasopharynx. 6- d(bony depth of nasopharynx. 7- h (bony height of nasopharynx.Statistical t-test was conducted following calculating the mean, standard deviation and p-value of parameters. Discriminant function analysis was employed subsequent to thet-test for the significant variables, in order to find a method by which the values for several variables could be used simultaneously to determine whether obstruction exists.Qualitative variables of sex and age groups (6-10, 11-12, and 13-15 years old were alsoused in discriminant analysis.Results: In the study group, mean value of pp, Ad.pmp, air area, Np area and Ba.pmp were significantly decreased, whereas mean of d and h variables were not considerably lessened. After performing analysis stage, the following discriminant function equationwith critical point of 3.88 and correct classification of 94.57% was determined:D=0.345 (pp +0.064 (Ad.pmp-0.001(NP area + 0.03(Air area +0.505(Age1.If a person’s age is

  6. AIRIX: a new tool for flash radiography in detonics

    Science.gov (United States)

    Cavailler, Claude

    2001-04-01

    AIRIX is an induction linear accelerator which will be used for flash radiography in Commissariat A L'Energie Atomique In France. Designed to produce an X-ray dose of some hundreds Rads at 1 meter with an X-ray focal spot size diameter of less than 2 mm (LANL-CEA DAM definition), this facility consists in a 3,8 MeV/2 kA pulsed electron injector and 15,4 MeV induction accelerator powered by 32 high voltage generators. A prototype of this accelerator, called PIVAIR, has been studied and realized in CEA CESTA near Bordeaux. PIVAIR is a validation step for AIRIX at 8 MeV. It includes an injector (3,6 MeV, 3,2 kA, 60 ns) and 16 induction cells supplied by 8 high voltage generators (250 kV, 70 ns). Two different technologies of induction cells have been tested (Rexolite insulator or ferrite Under Vacuum). We have chosen ferrite under vacuum cells technology after comparison of results on beam transport and reliability tests. A focusing experiment at 7.2 MeV of the electron beam has been achieved during summer 1997. We have begun to produce X-rays in October 1997. A dose level of 50 Rad at 1 meter has been achieved with an X-ray spot size diameter of 3.5 to 4 mm (LANL-CEA DAM definition). Static flash radiography of very dense object have been achieved from November 1997 until February 1998. We have been able to test in situ new kinds of very high sensitive X-ray detectors and to check they had reached our very ambitious goals: quantum efficiency at 5 MeV > 50% instead of 1% for luminous screens and film, sensitivity radiographic luminous screens and films), dynamic range > 100, resolution radiograph of the device explosion under test with the high stopping power detector located in a blast protection set behind the device. In this communication we will present all these techniques which correspond to a significant effort of CEA begun in 1992. AIRIX facility will be available to run detonics experiments before end of 2000.

  7. Mit1 Transcription Factor Mediates Methanol Signaling and Regulates the Alcohol Oxidase 1 (AOX1) Promoter in Pichia pastoris.

    Science.gov (United States)

    Wang, Xiaolong; Wang, Qi; Wang, Jinjia; Bai, Peng; Shi, Lei; Shen, Wei; Zhou, Mian; Zhou, Xiangshan; Zhang, Yuanxing; Cai, Menghao

    2016-03-18

    The alcohol oxidase 1 (AOX1) promoter (P AOX1) of Pichia pastoris is the most powerful and commonly used promoter for driving protein expression. However, mechanisms regulating its transcriptional activity are unclear. Here, we identified a Zn(II)2Cys6-type methanol-induced transcription factor 1 (Mit1) and elucidated its roles in regulating PAOX1 activity in response to glycerol and methanol. Mit1 regulated the expression of many genes involved in methanol utilization pathway, including AOX1, but did not participate in peroxisome proliferation and transportation of peroxisomal proteins during methanol metabolism. Structural analysis of Mit1 by performing domain deletions confirmed its specific and critical role in the strict repression of P AOX1 in glycerol medium. Importantly, Mit1, Mxr1, and Prm1, which positively regulated P AOX1 in response to methanol, were bound to P AOX1 at different sites and did not interact with each other. However, these factors cooperatively activated P AOX1 through a cascade. Mxr1 mainly functioned during carbon derepression, whereas Mit1 and Prm1 functioned during methanol induction, with Prm1 transmitting methanol signal to Mit1 by binding to the MIT1 promoter (P MIT1), thus increasingly expressing Mit1 and subsequently activating P AOX1.

  8. Charakterisierung und Optimierung der Grenzflächenstabilisierung von Wasser-in-Öl-Emulsionen mit Ethylcellulose als Polymeremulgator

    OpenAIRE

    Maurath, Stephan

    2007-01-01

    Die (Lager-)Stabilität ausschließlich mit Ethylcellulose (EC) stabilisierter, gießfähiger W/O-Emulsionen mit Octyldodecanol als Ölphase ist für eine praktische Anwendung nicht ausreichend. Ziel der vorliegenden Arbeit ist – aufbauend auf eine systematische Charakterisierung – eine Optimierung der Grenzflächenstabilisierung ausschließlich mit Ethylcellulose stabilisierter, gießfähiger W/O-Emulsionen. Mit Hilfe von Messungen der dynamischen Grenzflächenspannungen und Grenzflächen-rheologie (...

  9. Die "Single-Shot-Therapie" für Patientinnen mit unkompliziertem Harnwegsinfekt

    Directory of Open Access Journals (Sweden)

    Hanzal E

    1999-01-01

    Full Text Available Der Harntrakt ist bei der Frau aus anatomischen und hormonellen Gründen einer der häufigsten Angriffspunkte bakterieller Infektionen. Als Risikofaktoren gelten Kohabitationen, die Verwendung bestimmter Kontrazeptiva (spermizide Creme und/oder Scheidendiaphragma und vorangegangene Zystitiden. Unkomplizierte Harnwegsinfekte sind mittels gezielter Anamnese, klinischer Untersuchung und Streifentest im Rahmen einer abgekürzten Diagnostik leicht festzustellen. Der Verzicht auf eine antibiotische Therapie ist aufgrund der möglichen gefährlichen Folgen (Pyelonephritis, Urosepsis, Nierenversagen medizinisch nicht vertretbar. Erfahrungsgemäß ist allerdings die Patientencompliance ein Problem, die neben der Gefahr der Reinfektion auch die Möglichkeit der Resistenzentwicklung birgt. Der Trend in der Therapie der unkomplizierten Harnwegsinfektion geht daher zur Kurzzeitbehandlung (3 Tage mit potenten bakteriziden Substanzen. Mit der Zulassung von Fosfomycin-Tromethamol (Monuril® steht darüberhinaus neuerdings ein Präparat zur Verfügung, das mit einer oralen Einmaldosis eine hohe Wirksamkeit bietet, die sich mit der mehrtägigen Gabe anderer Substanzen auch im Nebenwirkungsprofil vergleichen läßt. Aus gynäkologischer Sicht ist außerdem beachtenswert, daß Fosfomycin-Tromethamol auch beim Harnwegsinfekt in der Schwangerschaft eingesetzt werden kann. Die Single-Shot Therapie mit Fosfomycin-Tromethamol (Monuril® kann somit als wirksame und sichere Behandlungsmethode des akuten unkomplizierten Harnwegsinfektes gelten.

  10. Designs of LiMIT as a Limiter in the EAST Tokamak

    Science.gov (United States)

    Szott, Matthew; Christenson, Michael; Kalathiparambil, Kishor; Ruzic, David

    2016-10-01

    Liquid metal plasma facing components (PFCs) provide a constantly refreshing, self-healing surface that can reduce erosion and thermal stress damage to prolong device lifetime, and additionally decrease edge recycling, reduce impurities, and enhance plasma performance. The Liquid Metal Infused Trench (LiMIT) system, developed at UIUC, has demonstrated thermoelectric magnetohydrodynamic (TEMHD) driven flow of liquid lithium through series of solid trenches. This TEMHD effect drives liquid lithium in fusion systems using the plasma heat flux and the toroidal magnetic field, and the surface tension of the liquid lithium maintains a fresh surface on top of the solid trenches. LiMIT has been successfully tested at UIUC as well as HT-7 and Magnum PSI at heat fluxes up to 3 MW/m2. The next step is demonstrating system viability in full-scale fusion-relevant conditions. In collaboration with a team in Hefei, design and testing has begun for a large scale LiMIT system that will act as a limiter in EAST. The designs improve upon previous versions of LiMIT tested at Illinois and incorporate lessons learned from earlier tests of liquid metal PFCs at EAST. Existing infrastructure is used to load and supply lithium to the system, and the LiMIT trenches will help maintain a smooth, fresh surface as well as aid in propelling the lithium out of direct plasma flux to improve heat transfer. Supported by DOE/ALPS DE-FG02-99ER54515.

  11. The knockdown of OsVIT2 and MIT affects iron localization in rice seed.

    Science.gov (United States)

    Bashir, Khurram; Takahashi, Ryuichi; Akhtar, Shamim; Ishimaru, Yasuhiro; Nakanishi, Hiromi; Nishizawa, Naoko K

    2013-11-20

    The mechanism of iron (Fe) uptake in plants has been extensively characterized, but little is known about how Fe transport to different subcellular compartments affects Fe localization in rice seed. Here, we discuss the characterization of a rice vacuolar Fe transporter 2 (OsVIT2) T-DNA insertion line (osvit2) and report that the knockdown of OsVIT2 and mitochondrial Fe transporter (MIT) expression affects seed Fe localization. osvit2 plants accumulated less Fe in their shoots when grown under normal or excess Fe conditions, while the accumulation of Fe was comparable to that in wild-type (WT) plants under Fe-deficient conditions. The accumulation of zinc, copper, and manganese also changed significantly in the shoots of osvit2 plants. The growth of osvit2 plants was also slow compared to that of WT plants. The concentration of Fe increased in osvit2 polished seeds. Previously, we reported that the expression of OsVIT2 was higher in MIT knockdown (mit-2) plants, and in this study, the accumulation of Fe in mit-2 seeds decreased significantly. These results suggest that vacuolar Fe trafficking is important for plant Fe homeostasis and distribution, especially in plants grown in the presence of excess Fe. Moreover, changes in the expression of OsVIT2 and MIT affect the concentration and localization of metals in brown rice as well as in polished rice seeds.

  12. Radiological protection procedures for industrial applications of computed radiography; Procedimentos de protecao radiologica em aplicacoes industriais da radiografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Aquino, Josilto Oliveira de

    2009-03-15

    Due to its very particular characteristics, industrial radiography is responsible for roughly half of the relevant accidents in nuclear industry, in developed as well as in developing countries, according to the International Atomic Energy Agency (IAEA). Thus, safety and radiological protection in industrial gamma radiography have been receiving especial treatment by regulatory authorities of most Member States. The main objective of the present work was to evaluate, from the radioprotection point of view, the main advantages of computed radiography (CR) for filmless industrial radiography. In order to accomplish this, both techniques, i.e. conventional and filmless computed radiography were evaluated and compared through practical studies. After the studies performed at the present work it was concluded that computed radiography significantly reduces the inherent doses, reflecting in smaller restricted areas and costs, with consequent improvement in radiological protection and safety. (author)

  13. Photon counting detector for the personal radiography inspection system "SIBSCAN"

    Science.gov (United States)

    Babichev, E. A.; Baru, S. E.; Grigoriev, D. N.; Leonov, V. V.; Oleynikov, V. P.; Porosev, V. V.; Savinov, G. A.

    2017-02-01

    X-ray detectors operating in the energy integrating mode are successfully used in many different applications. Nevertheless the direct photon counting detectors, having the superior parameters in comparison with the integrating ones, are rarely used yet. One of the reasons for this is the low value of the electrical signal generated by a detected photon. Silicon photomultiplier (SiPM) based scintillation counters have a high detection efficiency, high electronic gain and compact dimensions. This makes them a very attractive candidate to replace routinely used detectors in many fields. More than 10 years ago the digital scanning radiography system based on multistrip ionization chamber (MIC) was suggested at Budker Institute of Nuclear Physics. The detector demonstrates excellent radiation resistance and parameter stability after 5 year operations and an imaging of up to 1000 persons per day. Currently, the installations operate at several Russian airports and at subway stations in some cities. At the present time we design a new detector operating in the photon counting mode, having superior parameters than the gas one, based on scintillator - SiPM assemblies. This detector has close to zero noise, higher quantum efficiency and a count rate capability of more than 5 MHz per channel (20% losses), which leads to better image quality and improved detection capability. The suggested detector technology could be expanded to medical applications.

  14. Application of digital radiography for measuring in clinical dental practice

    Directory of Open Access Journals (Sweden)

    Ilić Dragan V.

    2015-01-01

    Full Text Available Introduction. The recent literature data points out a rising application of digital radiography - radiovisiography (RVG - in dental clinical practice. Objective. The aim of this study was to apply and compare RVG with the conventional radiographic technique (CRDG in terms of accuracy in linear measurement in dentistry. Methods. Measurements were done on the mandibular dogs teeth considering incisors crown width and height of the surrounding alveolar bone using RVG and CRDG. The control technique (CONT involved values obtained by direct gauging in dogs mouth. Each measuring was done by two examiners. Results. Considering the incisors’ crown width, there were no significant statistical difference in measurement using CRDG, RVG and CONT technique (p>0.01. Concerning the alveolar height gauging there were no significant difference in recorded values between the two radiographic techniques (p>0.01. The high level of inter-examiner agreement was observed for scoring in all techniques (CRDG, RVG and CONT. Conclusion. Although RVG did not expose more accuracy comparing to CRDG, having opulent tool service the first technique contributed more comfortable work during measuring procedures in this study.

  15. Measuring and correcting wobble in large-scale transmission radiography

    CERN Document Server

    Rogers, Thomas W; Morton, Edward J; Griffin, Lewis D

    2016-01-01

    Large-scale transmission radiography scanners are used to image vehicles and cargo containers. Acquired images are inspected for threats by a human operator or a computer algorithm. To make accurate detections, it is important that image values are precise. However, due to the scale of such systems, they can be mechanically unstable, causing the imaging array to wobble during a scan. This leads to an effective loss of precision in the captured image. We consider the measurement of wobble and amelioration of the consequent loss of image precision. Following our previous work, we use Beam Position Detectors (BPDs) to measure the cross-sectional profile of the X-ray beam, allowing for estimation, and thus correction of wobble. We propose: (i) a model of image formation with a wobbling detector array; (ii) a method of wobble correction derived from this model; (iii) methods for calibrating sensor sensitivities and relative offsets; (iv) a Random Regression Forest based method for instantaneous estimation of detec...

  16. A conceptual optimisation strategy for radiography in a digital environment.

    Science.gov (United States)

    Båth, Magnus; Håkansson, Markus; Hansson, Jonny; Månsson, Lars Gunnar

    2005-01-01

    Using a completely digital environment for the entire imaging process leads to new possibilities for optimisation of radiography since many restrictions of screen/film systems, such as the small dynamic range and the lack of possibilities for image processing, do not apply any longer. However, at the same time these new possibilities lead to a more complicated optimisation process, since more freedom is given to alter parameters. This paper focuses on describing an optimisation strategy that concentrates on taking advantage of the conceptual differences between digital systems and screen/film systems. The strategy can be summarised as: (a) always include the anatomical background during the optimisation, (b) perform all comparisons at a constant effective dose and (c) separate the image display stage from the image collection stage. A three-step process is proposed where the optimal setting of the technique parameters is determined at first, followed by an optimisation of the image processing. In the final step the optimal dose level-given the optimal settings of the image collection and image display stages-is determined.

  17. Bacteriological research for the contamination of digital portable radiography

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Seong Gyu [Dept. of Radiology, Dong A University Hospital, Busan (Korea, Republic of); Lee, Hyo Yeong [Dept. of Radiological Science, Dong Eui University, Busan (Korea, Republic of)

    2017-03-15

    The study was performed to investigate the bacteriological contamination of portable digital radiography system and their detectors in a university hospital. CNS and VRE were detected in the samples collected from vinyl cover on detectors used for the infection control patients. On the other hand, no bacteria was detected in the samples collected from detectors with vinyl cover removed. In the series of imaging of patients from general wards, no bacteria was detected from the patient 1. However, CNS was detected from the patients 2 and 3, CNS and Enterococcus faecalis detected from the patient 4, CNS and Enterococcus casseliflavus detected from the patient 5, and CNS, Enterococcus casseliflavus, and Klebsiella pneumoniae all detected from the patient 6. CNS and Enterococcus faecium were detected in the controller handle of collimator. Also, CNS was detected from the handle of detector and exposure switch. In the treatment gloves of the radiological technologist after the imaging, CNS, Enterococcus gallinarum, and Klebsiella pneumoniae were detected. Therefore, it is recommended for DR portable to take images after sterilizing the detector after taking each image and to use disposable vinyl covers on detectors to remove after imaging. And treatment gloves must be changed after each imaging. Also, hospital infection via portables must be prevented by complete sterilization of the controller handles of collimator which are in frequent contact during imaging and infection education of employees.

  18. Location of mental foramen using digital panoramic radiography

    Directory of Open Access Journals (Sweden)

    Ajmal Mohamed

    2016-01-01

    Full Text Available Objective: Comparative evaluation of the location of mental foramen in different age groups. Determine the variation in position of mental foramen with gender using digital panoramic radiography. Materials and Methods: Digital panoramic radiographs of 250 patients were reviewed. The study population was divided into five age groups with 50 patients each. Radiographic position of mental foramen was evaluated in each radiograph based on three parameters. Measurements were taken in each radiograph using Planmeca Dimaxis pro version 4.4.0 (Helsinki, Finland. The collected data were subjected to statistical analysis using paired Student's t-test. Results: The mean distance of position of mental foramen showed a significant variation within the five age groups. In the first group, female patients showed an increase in mean distance of mental foramen position in relation to three parameters. From the second to fifth groups, male patient showed an increase in the mean distance of mental foramen position. The first and fifth group showed a reduced mean distance of mental foramen position when compared to other age groups. Conclusion: This study concluded that the position of mental foramen varies with age. There was a gender-related variation in position of mental foramen within the population too.

  19. Location of mental foramen using digital panoramic Radiography

    Science.gov (United States)

    Mohamed, Ajmal; Nataraj, Kannan; Mathew, Vinod B.; Varma, Beena; Mohamed, Shamil; Valappila, Nidhin J.; Meena, Aravind S.

    2016-01-01

    Objective: Comparative evaluation of the location of mental foramen in different age groups. Determine the variation in position of mental foramen with gender using digital panoramic radiography. Materials and Methods: Digital panoramic radiographs of 250 patients were reviewed. The study population was divided into five age groups with 50 patients each. Radiographic position of mental foramen was evaluated in each radiograph based on three parameters. Measurements were taken in each radiograph using Planmeca Dimaxis pro version 4.4.0 (Helsinki, Finland). The collected data were subjected to statistical analysis using paired Student's t-test. Results: The mean distance of position of mental foramen showed a significant variation within the five age groups. In the first group, female patients showed an increase in mean distance of mental foramen position in relation to three parameters. From the second to fifth groups, male patient showed an increase in the mean distance of mental foramen position. The first and fifth group showed a reduced mean distance of mental foramen position when compared to other age groups. Conclusion: This study concluded that the position of mental foramen varies with age. There was a gender-related variation in position of mental foramen within the population too. PMID:27555723

  20. Quantitative shadowgraphy and proton radiography for large intensity modulations

    Science.gov (United States)

    Kasim, Muhammad Firmansyah; Ceurvorst, Luke; Ratan, Naren; Sadler, James; Chen, Nicholas; Sävert, Alexander; Trines, Raoul; Bingham, Robert; Burrows, Philip N.; Kaluza, Malte C.; Norreys, Peter

    2017-02-01

    Shadowgraphy is a technique widely used to diagnose objects or systems in various fields in physics and engineering. In shadowgraphy, an optical beam is deflected by the object and then the intensity modulation is captured on a screen placed some distance away. However, retrieving quantitative information from the shadowgrams themselves is a challenging task because of the nonlinear nature of the process. Here, we present a method to retrieve quantitative information from shadowgrams, based on computational geometry. This process can also be applied to proton radiography for electric and magnetic field diagnosis in high-energy-density plasmas and has been benchmarked using a toroidal magnetic field as the object, among others. It is shown that the method can accurately retrieve quantitative parameters with error bars less than 10%, even when caustics are present. The method is also shown to be robust enough to process real experimental results with simple pre- and postprocessing techniques. This adds a powerful tool for research in various fields in engineering and physics for both techniques.

  1. Evaluation of entrance surface air kerma in pediatric chest radiography

    Science.gov (United States)

    Porto, L.; Lunelli, N.; Paschuk, S.; Oliveira, A.; Ferreira, J. L.; Schelin, H.; Miguel, C.; Denyak, V.; Kmiecik, C.; Tilly, J.; Khoury, H.

    2014-11-01

    The objective of this study was to evaluate the entrance surface air kerma in pediatric chest radiography. An evaluation of 301 radiographical examinations in anterior-posterior (AP) and posterior-anterior (PA) (166 examinations) and lateral (LAT) (135 examinations) projections was performed. The analyses were performed on patients grouped by age; the groups included ages 0-1 y, 1-5 y, 5-10 y, and 10-15 y. The entrance surface air kerma was determined with DoseCal software (Radiological Protection Center of Saint George's Hospital, London) and thermoluminescent dosimeters. Two different exposure techniques were compared. The doses received by patients who had undergone LAT examinations were 40% higher, on average, those in AP/PA examinations because of the difference in tube voltage. A large high-dose “tail” was observed for children up to 5 y old. An increase in tube potential and corresponding decrease in current lead to a significant dose reduction. The difference between the average dose values for different age ranges was not practically observed, implying that the exposure techniques are still not optimal. Exposure doses received using the higher tube voltage and lower current-time product correspond to the international diagnostic reference levels.

  2. Development of Automatic Remote Exposure Controller for Gamma Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Gwang Tae; Shin, Jin Seong; Kim, Dong Eun; Song, Jung Ho; Choo, Seung Hwan; Chang, Hong Keun [Korea Industrial Testing Co., Ltd., Seoul (Korea, Republic of)

    2002-10-15

    Recently, gamma radiographic equipment have been used about 1,000 sets manually and operated by about 2,500 persons in Korea. In order for a radiography to work effectively with avoiding any hazard of the high level radiation from the source, many field workers have expected developing a wireless automatic remote exposure controller. The KlTCO research team has developed an automatic remote exposure controller that can regulate the speed of 0.4{approx}1.2m/s by BLDC motor of 24V 200W which has output of 54 kgf{center_dot}, suitable torque and safety factor for the work. And the developed automatic remote exposure controller can control rpm of motor, pigtail position by photo-sensor and exposure time by timer to RF sensor. Thus, the developed equipment is expected that the unit can be used in many practical applications with benefits in economical advantage to combine the use of both automatic and manual type because attachment is possible existent manual remote exposure controller, AC and DC combined use

  3. Asymptomatic Intracranial Foreign Body: An Incidental Finding on Radiography

    Directory of Open Access Journals (Sweden)

    Maghsoudi

    2016-05-01

    Full Text Available Introduction Intracranial needles are rare entities. Intracranial foreign bodies due to non-missile intracranial penetrations are one of the most rarely encountered situations in neurosurgery. Sewing needles are among the more unusual foreign bodies that may be found in the brain. Although uncommon, foreign body cases are important and interesting. Foreign bodies enter the body through trauma or iatrogenic injuries. Needles are mostly inserted through fontanelles, cranial sutures, and more rarely through the orbits in infancy for the purpose of killing unwanted babies. Case Presentation This article presents a case of intracranial foreign body found upon radiography. A 24-year-old female, who two days prior to presentation suffered only once from dizziness, and was otherwise healthy. Conclusions Because this incident may have occurred during the patient’s neonatal period, it may be a case of child abuse. In spite of the very limited number of cases in the literature, having a stepmother, a stepfather, or a babysitter, being the youngest child, or having family members who suffer from psychiatric disorders, (especially if these relatives are responsible for child care, living in a society that allows homicide of children born from extramarital relationships, and being female have been suggested as possible risk factors.

  4. Atlantoaxial subluxation. Radiography and magnetic resonance imaging correlated to myelopathy

    Energy Technology Data Exchange (ETDEWEB)

    Yamashita, Y.; Takahashi, M.; Sakamoto, Y.; Kojima, R.

    Twenty-nine patients with atlantoaxial subluxation (18 with rheumatoid arthritis, 2 due to trauma, 4 with os odontoideum, and one each with polyarteritis nodosa, rheumatic fever, Klippel-Feil syndrome, achondroplasia, and cause unknown) were evaluated using a 0.22 tesla resistive MRI unit. Cord compression was classified into four grades according to the degree on magnetic resonance imaging. There were 7 patients with no thecal sac compression (grade 0), 10 with a minimal degree of subarachnoid space compression without cord compression (grade 1), 7 with mild cord compression (grade 2), and 5 with severe cord compression or cord atrophy (grade 3). Although the severity of myelopathy showed poor correlation with the atlantodental interval on conventional radiography, high correlation was observed between MR grading and the degree of myelopathy. The high signal intensity foci were observed in 7 or 12 patients with cord compression (grades 2 and 3) on T2 weighted images. Other frequently observed findings in rheumatoid arthritis included soft tissue masses of low to intermediate signal intensity in the paraodontoid space, erosions of the odontoid processes, and atlanto-axial impaction on T1 and T2 weighted images.

  5. Digital Radiography and Computed Tomography (DRCT) Product Improvement Plan (PIP)

    Energy Technology Data Exchange (ETDEWEB)

    Tim Roney; Bob Pink; Karen Wendt; Robert Seifert; Mike Smith

    2010-12-01

    The Idaho National Laboratory (INL) has been developing and deploying x-ray inspection systems for chemical weapons containers for the past 12 years under the direction of the Project Manager for Non-Stockpile Chemical Materiel (PMNSCM). In FY-10 funding was provided to advance the capabilities of these systems through the DRCT (Digital Radiography and Computed Tomography) Product Improvement Plan (PIP), funded by the PMNSCM. The DRCT PIP identified three research tasks; end user study, detector evaluation and DRCT/PINS integration. Work commenced in February, 2010. Due to the late start and the schedule for field inspection of munitions at various sites, it was not possible to spend sufficient field time with operators to develop a complete end user study. We were able to interact with several operators, principally Mr. Mike Rowan who provided substantial useful input through several discussions and development of a set of field notes from the Pueblo, CO field mission. We will be pursuing ongoing interactions with field personnel as opportunities arise in FY-11.

  6. Micro-radiography of biological samples with medical contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@lf1.cuni.cz [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Weyda, F. [Faculty of Science, University of South Bohemia, Branisovska 31, 370 05 Ceske Budejovice (Czech Republic); Benes, J. [Charles University in Prague, First Faculty of Medicine, Salmovská 1, 120 00 Prague 2 (Czech Republic); Sopko, V. [Hospital Na Bulovce, Department of Radiological Physics, Budinova 2, 180 81 Prague 8 (Czech Republic); Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, 128 00 Prague 2 (Czech Republic); Gelbic, I. [Biology Centre, AS CR, Institute of Entomology, Department of Biochemistry and Physiology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic)

    2013-12-01

    Micro-radiography is an imaging technique that uses X-rays to study the internal structures of objects. This fast and easy imaging tool is based on differential X-ray attenuation by various tissues and structures within biological samples. The experimental setup described is based on the semiconductor pixel X-ray detector Medipix2 and X-ray micro-focus tube. Our micro-radiographic system has been recently used not only for the examination of internal structures of various arthropods and other biological objects but also for tracing some processes in selected model species (we used living larvae of mosquito Culex quinquefasciatus). Low concentrations of iodine, lanthanum or gold particles were used as a tracer (contrast agent). Such contrast agents increase the absorption of X-rays and allow a better visibility of internal structures of model organisms (especially the various cavities, pores, etc.). In addition, the movement of tracers in selected timing experiments demonstrates some physiological functions of digestive and excretory system.

  7. Assessment and prevention of the professional risks in the operations of industrial radiography; Evaluation et prevention des risques professionnels dans les operations de radiographie industrielle

    Energy Technology Data Exchange (ETDEWEB)

    Pizzorno, M.; Paul, D.; Coletti, F.; Sari Minodier, I.; Azzopardi, G.; Klemenic, O.; Botta, A. [Aix-Marseille-2 Univ., Lab. de Biogenotoxicologie et Mutagenese Environnementale (EA 1784 - IFR PMSE 112) Faculte de Medecine, 13 - Marseille (France)

    2006-07-01

    Industrial radiography is a nocturnal activity, hazardous and little known; it is among the professions the most exposed to ionizing radiation. This study analyse the doses, received the industrial radiographers, their workplace conditions and organization of their tasks. Dosimetry observations on site, together with calculations using the Mercurad code, allowed mean values for reference doses for all the work (including transport, gammatron manipulation, collimator manipulation, shooting) to be established. These value were integrated into a table entitled 'reference doses' in order to provisionally evaluate the doses received by the operators. Distances for security zone demarcation, so as to forbid access to non exposed personnel during shooting, were evaluated. Assessment of the professional risks for industrial radiography, taking into account all the risks (radiological and others), has been made and is under evaluation. This led to measures for prevention based on the material used (collimator, tripod, gamma-stops), on the organization and the conditions of work (for example, time limits permitting a prior visit to the site and preparation for radiography, suitable scaffolding, sufficient lighting, siting of shootings). These prevention measure will be integrated into the new charter of good practice in industrial radiography in the Provence Alpes Cote d'Azur region (south of France). (authors)

  8. MITR-III: Upgrade and relicensing studies for the MIT Research Reactor. Second annual report

    Energy Technology Data Exchange (ETDEWEB)

    Trosman, H.G. [ed.; Lanning, D.D.; Harling, O.K.

    1994-08-01

    The current operating license of the MIT research reactor will expire on May 7, 1996 or possibly a few years later if the US Nuclear Regulatory Commission agrees that the license period can start with the date of initial reactor operation. Driven by the imminent expiration of the operating license, a team of nuclear engineering staff and students have begun a study of the future options for the MIT Research Reactor. These options have included the range from a major rebuilding of the reactor to its decommissioning. This document reports the results of a two year intensive activity which has been supported by a $148,000 grant from the USDOE contract Number DEFG0293ER75859, approximately $100,000 of internal MIT funds and Nuclear Engineering Department graduate student fellowships as well as assistance from international visiting scientists and engineers.

  9. MIT Clean Energy Prize: Final Technical Report May 12, 2010 - May 11, 2011

    Energy Technology Data Exchange (ETDEWEB)

    Snyder, Chris [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Campbell, Georgina [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Salony, Jason [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States); Aulet, Bill [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2011-08-09

    The MIT Clean Energy Prize (MIT CEP) is a venture creation and innovation competition to encourage innovation in the energy space, specifically with regard to clean energy. The Competition invited student teams from any US university to submit student-led ventures that demonstrate a high potential of successfully making clean energy more affordable, with a positive impact on the environment. By focusing on student ventures, the MIT CEP aims to educate the next generation of clean energy entrepreneurs. Teams receive valuable mentoring and hard deadlines that complement the cash prize to accelerate development of ventures. The competition is a year-long educational process that culminates in the selection of five category finalists and a Grand Prize winner and the distribution of cash prizes to each of those teams. Each entry was submitted in one of five clean energy categories: Renewables, Clean Non-Renewables, Energy Efficiency, Transportation, and Deployment.

  10. Hyperhomocysteinämie bei Patienten mit koronarer Herzkrankheit vor aortokoronarer Bypass-Operation (CABG

    Directory of Open Access Journals (Sweden)

    Stanger O

    1999-01-01

    Full Text Available Erhöhte Plasmakonzentrationen der schwefelhaltigen Aminosäure Homocystein (Hcy wurden mit einer frühzeitigen Entwicklung arteriosklerotischer Gefäßveränderungen, thromboembolischer Komplikationen und schlechter Prognose der koronaren Herzkrankheit (KHK in Verbindung gebracht. Um das Vorkommen einer Hyperhomocysteinämie und die Wertigkeit des oralen Methionin-Belastungs-Tests (oMBT bei Patienten mit angiographisch nachgewiesener koronaren Herzkrankheit unmittelbar vor einer geplanten aortokoronaren Bypass-Operation (CABG zu untersuchen, wurde bei 150 KHK-Patienten und 80 gesunden Kontrollen nüchtern und 6 Stunden nach Methionin-Belastung totales Homocystein (tHcy im Plasma gemessen, ebenso u. a. Folsäure (Plasma und die Vitamine B6 und B12. Insgesamt hatten 32 % der Patienten eine Hyperhomocysteinämie. Die Höhe von Homocystein korrelierte dabei signifikant mit der Folsäure, ebenso der Anstieg unter Belastung und grenzwertig mit dem Body Mass Index (BMI. Ein solcher Zusammenhang konnte nicht für die Vitamine B6, B12 sowie Cholesterin, Triglyceride und Fibrinogen beobachtet werden. 37% der Patienten mit erhöhten Hcy-Werten wurden nur durch den Einsatz des oMBT erkannt. Daraus schließen wir, daß die Prävalenz einer Hyperhomocysteinämie in der untersuchten Patientengruppe im Vergleich zu einer gesunden Population sehr hoch ist. Der orale Methionin-Belastungs-Test stellt ein wichtiges Mittel zur Identifizierung von Patienten mit Hyperhomocysteinämie dar, dessen Einsatz den Aufwand rechtfertigt.

  11. The R Package MitISEM: Efficient and Robust Simulation Procedures for Bayesian Inference

    Directory of Open Access Journals (Sweden)

    Nalan Baştürk

    2017-07-01

    Full Text Available This paper presents the R package MitISEM (mixture of t by importance sampling weighted expectation maximization which provides an automatic and flexible two-stage method to approximate a non-elliptical target density kernel - typically a posterior density kernel - using an adaptive mixture of Student t densities as approximating density. In the first stage a mixture of Student t densities is fitted to the target using an expectation maximization algorithm where each step of the optimization procedure is weighted using importance sampling. In the second stage this mixture density is a candidate density for efficient and robust application of importance sampling or the Metropolis-Hastings (MH method to estimate properties of the target distribution. The package enables Bayesian inference and prediction on model parameters and probabilities, in particular, for models where densities have multi-modal or other non-elliptical shapes like curved ridges. These shapes occur in research topics in several scientific fields. For instance, analysis of DNA data in bio-informatics, obtaining loans in the banking sector by heterogeneous groups in financial economics and analysis of education's effect on earned income in labor economics. The package MitISEM provides also an extended algorithm, 'sequential MitISEM', which substantially decreases computation time when the target density has to be approximated for increasing data samples. This occurs when the posterior or predictive density is updated with new observations and/or when one computes model probabilities using predictive likelihoods. We illustrate the MitISEM algorithm using three canonical statistical and econometric models that are characterized by several types of non-elliptical posterior shapes and that describe well-known data patterns in econometrics and finance. We show that MH using the candidate density obtained by MitISEM outperforms, in terms of numerical efficiency, MH using a simpler

  12. Long-lived mitochondrial (Mit) mutants of Caenorhabditis elegans utilize a novel metabolism.

    Science.gov (United States)

    Butler, Jeffrey A; Ventura, Natascia; Johnson, Thomas E; Rea, Shane L

    2010-12-01

    The Caenorhabditis elegans mitochondrial (Mit) mutants have disrupted mitochondrial electron transport chain (ETC) functionality, yet, surprisingly, they are long lived. We have previously proposed that Mit mutants supplement their energy needs by exploiting alternate energy production pathways normally used by wild-type animals only when exposed to hypoxic conditions. We have also proposed that longevity in the Mit mutants arises as a property of their new metabolic state. If longevity does arise as a function of metabolic state, we would expect to find a common metabolic signature among these animals. To test these predictions, we established a novel approach monitoring the C. elegans exometabolism as a surrogate marker for internal metabolic events. Using HPLC-ultraviolet-based metabolomics and multivariate analyses, we show that long-lived clk-1(qm30) and isp-1(qm150) Mit mutants have a common metabolic profile that is distinct from that of aerobically cultured wild-type animals and, unexpectedly, wild-type animals cultured under severe oxygen deprivation. Moreover, we show that 2 short-lived mitochondrial ETC mutants, mev-1(kn1) and ucr-2.3(pk732), also share a common metabolic signature that is unique. We show that removal of soluble fumarate reductase unexpectedly increases health span in several genetically defined Mit mutants, identifying at least 1 alternate energy production pathway, malate dismutation, that is operative in these animals. Our study suggests long-lived, genetically specified Mit mutants employ a novel metabolism and that life span may well arise as a function of metabolic state.

  13. Parallel substrate monitoring in small-volume bioreactors; Parallele Substratkontrolle in Bioreaktoren mit geringem Volumen

    Energy Technology Data Exchange (ETDEWEB)

    Wolfram, E.P.

    2002-05-01

    In the first developmental phase of microbial processes, relevant parameters for reaction engineering are investigated and optimized with parallel experiments in small reactors (shake flask scale). Substrate concentrations are central process parameters. Their control might help to increase efficiency and quality of this developmental phase. Thus, a parallel, automatic and sterile sampling technique with hollow fiber membranes was developed that suits the small reaction volume. The parallel sampling modules were connected to a substrate analysis system. The combination of the analytical technique with a controller and a precise microdosing system for substrate closed the control loop. The prototype device was characterized and its suitability for online monitoring and control of bioprocesses confirmed. This technique allows for the first time online measurement and control of substrate concentrations in parallel bioreactions (i.e. with Escherichia coli) with measuring rates of the order of minutes. (orig.) [German] Mikrobielle Prozesse werden in der ersten Entwicklungsphase in Parallelexperimenten in Kleinreaktoren (Schuettelkolben-Massstab) reaktionstechnisch untersucht und optimiert. Substratkonzentrationen sind dabei eine zentrale Prozessgroesse, deren Kontrolle zur Steigerung der Effizienz und Qualitaet dieser Entwicklungsphase beitragen kann. Daher wurde eine fuer kleine Reaktionsvolumen geeignete parallele, automatische und sterile Probenahmetechnik mit Hohlfaser-Dialysemembranen entwickelt und mit einem Substrat-Analysesystem gekoppelt. Durch Kombination der Messtechnik mit einem Regler und einem praezisen Mikrodosiersystem fuer Substrat wurde der Regelkreis geschlossen. Das Funktionsmuster wurde verfahrenstechnisch charakterisiert und seine Eignung zur Online-Ueberwachung und Regelung von Bioprozessen untersucht. Mit dieser Technik gelang erstmals die Messung und Regelung von Substratkonzentrationen in parallel durchgefuehrten Bioreaktionen (beispielsweise

  14. Accuracy of Digital Bitewing Radiography versus Different Views of Digital Panoramic Radiography for Detection of Proximal Caries

    Science.gov (United States)

    Abdinian, Mehrdad; Razavi, Sayed Mohammad; Samety, Amir Abbas; Faghihian, Elham

    2015-01-01

    Objectives: Dental caries are common and have a high incidence among populations. Radiographs are essential for detecting proximal caries. The best technique should be recognized for accurate detection of caries. The aim of this study was to compare the accuracy of detection of proximal caries using intraoral bitewing, extraoral bitewing, improved interproximal panoramic, improved orthogonality panoramic and conventional panoramic radiographs. Materials and Methods: In this descriptive cross sectional study, 100 extracted human teeth with and without proximal caries were used. Intra and extraoral radiographs were taken. Images were evaluated and scored by two observers. Scores were compared with the histological gold standard. The diagnostic accuracy of radiographs was assessed by means of receiver operating characteristic (ROC) curve analysis (P<0.05). Results: Microscopic evaluation of proximal surfaces revealed that 54.8% of the surfaces were sound and 45.2% were carious (with different depths). The differences in the area under the ROC curve (Az value) among the five techniques were not statistically significant. Conclusion: Improved interproximal panoramic and extraoral bitewing radiographs were superior to conventional panoramic radiography for detection of proximal caries ex vivo and should be considered for patients with contraindications for intraoral radiographs. PMID:26622284

  15. Current radiography and tomography applications at Necsa and an envisaged upgrade towards a proposed South African national centre for radiography and tomography (SANCRAT)

    Energy Technology Data Exchange (ETDEWEB)

    Radebe, M.J.; De Beer, F.C. [Necsa - South African Nuclear Energy Corporation Limited, P. O.Box 582, Pretoria, 0001 (South Africa)

    2008-07-01

    An upgrade of the current Radiography and Tomography Research facilities is envisaged to enhance the group's support for Necsa's mission to undertake and support nuclear research and utilize penetrating radiation for the benefit of mankind. It is envisage that the SANCRAT will host neutron-, X-ray- and gamma ray penetrating radiation imaging infrastructures that can be utilized by researchers from industry as well as post graduate students from higher educational institutions. Modelling for the upgrade to a multifunctional neutron radiography and tomography facility has been underway. Upgrade plans and implementation has also begun for a 250 kV X-ray radiography set-up, that will exist independent from the neutron facility. Future expansion entails catering for a micro-focus X-ray -, and gamma ray radiography and tomography facilities. The current facilities available consist of one infrastructure facility based on two sources of penetrating radiation, i.e. SAFARI-1 research nuclear reactor as thermal neutron source and a 100 kV X-ray generator. This facility, which hosts the only operational neutron tomography R and D facility in the Southern Hemisphere and in Africa, are being extensively utilized by post graduate students and industry. The facility sees application in a wide range of scientific and engineering disciplines, amongst which is nuclear, geosciences, palaeontology, civil, mechanical, chemical, etc. This paper focus on case studies engaged at the current radiography and tomography facilities over the past 2 years as well as describing the envisaged upgrade initiatives to a fully equipped national centre. (authors)

  16. Steer-by-wire-Lenkung eines Agro-Hybrid-Fahrzeuges mit Einzelradantrieb

    Directory of Open Access Journals (Sweden)

    Jürgen Karner

    2014-04-01

    Full Text Available Für die Landschaftspflege in alpinen Regionen wurde ein kompakter, fernbedienbarer Geräteträger mit einer modernen und effizienten Antriebstechnik entwickelt. Der neue Geräteträger bietet eine gute Wendigkeit, einen tiefen Schwerpunkt und ermöglicht bodenschonende Lenkungsarten. In diesem Beitrag wird speziell das Rad-Drehzahl- und das Lenkungsmodell des mit Einzelradantrieb ausgestatteten Fahrzeuges vorgestellt. Damit soll für verschiedene Lenkungsarten der bestmögliche Betrieb erreicht werden.

  17. wienXtra-jugendinfo rat&hilfe Forum. Erfahrungen aus vier Jahren mit einem moderierten Jugendforum

    Directory of Open Access Journals (Sweden)

    Alexander Brunner

    2005-09-01

    Full Text Available Im Artikel werden die Erfahrungen aus der Arbeit mit einem moderierten Jugendforum dargestellt. Neben den Entwicklungen über die Jahre werden Themen wie Moderation, Communitybildung, Flaming, Registrierung etc. exemplarisch am rat&hilfe Forum veranschaulicht und reflektiert. So werden einerseits Einblicke in die praktischen Erfahrungen und die praktische Arbeit mit und in einem Jugendforum ermöglicht und anderseits bestimmte Phänomene in einer erweiterten und verallgemeinerten Form reflektiert. Auf diese Art und Weise können diese spezifischen Erfahrungen für ähnliche Projekte fruchtbare Anregungen bieten.

  18. Prolongierte iktale Hemiparese und Aphasie in Kombination mit PLEDs im EEG: ein Fallbericht

    Directory of Open Access Journals (Sweden)

    Leutmezer F

    2002-01-01

    Full Text Available Eine 89jährige Patientin wurde wegen eines konvulsiven Status epilepticus an einer internen Abteilung aufgenommen. In der Anamnese finden sich ein Zustand nach ischämischem Insult links hoch-parietal (2 Jahre vor Aufnahme, ein Zustand nach intrazerebraler Blutung in das Infarktareal (1 Jahr vor Aufnahme mit konsekutiver symptomatischer Epilepsie, die mit Lamotrigin gut eingestellt war, sowie ein chronisches, normofrequentes Vorhofflimmern. Anhand unseres Fallberichtes möchten wir mehrere Aspekte, die unserer Ansicht nach zum Teil von klinischer, zum Teil von theoretischer Bedeutung sind, herausstreichen.

  19. Telemedizin in der Sekundärprävention: ein Feldversuch mit asthmakranken Jugendlichen

    OpenAIRE

    Huber, Thomas; Diemer, Robert; Kreuzer, Johannes

    2008-01-01

    Die Führung eines Asthma-Tagebuchs erfordert gerade von erkrankten Kindern und Jugendlichen sehr viel Disziplin. So sollen mehrmals täglich Peak-Flow-Werte mit Uhrzeit und Datum, eingenommene Medikamente und eventuell aufgetretene Beschwerden notiert werden, um den behandelnden Ärzten bessere Betreuungs- und Therapiemöglichkeiten zu bieten. In diesem Beitrag wird die Problematik erläutert und aufgezeigt, wie mit Hilfe einer mobilen Anwendung von InprimoTM versucht wird, die Compliance der jun...

  20. Langzeiteffekte der FM-Versorgung bei Kindern mit AVWS, Subtyp "Auditive Selektionsstörung"

    OpenAIRE

    Braun, S.; Schönweiler, R

    2010-01-01

    Hintergrund: Auditive Verarbeitungs- und/oder Wahrnehmungsstörungen können mit Übungstherapie, Kompensationsstrategien und mit akustischen Maßnahmen behandelt werden . FM-Anlagen gehören zu den "aktiven" akustischen Maßnahmen, für die mehr Studien zum Wirkungsnachweis wünschenswert sind. Auf der Jahrestagung der DGPP 2007 haben wir bereits über kurzfristige Effekte berichtet .Material und Methoden: In der vorliegenenden Arbeit haben wir die Studie als prospektive Einzelfallstudie fortgefüh...

  1. An advanced image processing method to improve the spatial resolution of ion radiographies

    Science.gov (United States)

    Krah, N.; Testa, M.; Brons, S.; Jäkel, O.; Parodi, K.; Voss, B.; Rinaldi, I.

    2015-11-01

    We present an optimization method to improve the spatial resolution and the water equivalent thickness (WET) accuracy of ion radiographies. The method is designed for imaging systems measuring for each actively scanned beam spot the lateral position of the pencil beam and at the same time the Bragg curve (behind the target) in discrete steps without relying on tracker detectors to determine the ion trajectory before and after the irradiated volume. Specifically, the method was used for an imaging set-up consisting of a stack of 61 parallel-plate ionization chambers (PPIC) interleaved with absorber plates of polymethyl methacrylate (PMMA) working as a range telescope. The method uses not only the Bragg peak position, but approximates the entire measured Bragg curve as a superposition of differently shifted Bragg curves. Their relative weights allow to reconstruct the distribution of thickness around each scan spot of a heterogeneous phantom. The approach also allows merging the ion radiography with the geometric information of a co-registered x-ray radiography in order to increase its spatial resolution. The method was tested using Monte Carlo simulated and experimental proton radiographies of a PMMA step phantom and an anthropomorphic head phantom. For the step phantom, the effective spatial resolution was found to be 6 and 4 times higher than the nominal resolution for the simulated and experimental radiographies, respectively. For the head phantom, a gamma index was calculated to quantify the conformity of the simulated proton radiographies with a digitally reconstructed radiography (DRR) obtained from an x-ray CT and properly converted into WET. For a distance-to-agreement (DTA) of 2.5 mm and a relative WET difference (RWET) of 2.5%, the passing ratio was 100%/85% for the optimized/non-optimized case, respectively. When the optimized proton radiography was merged with the co-registered DRR, the passing ratio was 100% at DTA  =  1.3 mm and RWET

  2. Der Bürocomputer in einem Informationsverbund : Erfahrungen mit einem computergestützten Büro-Informationssystem (COBIS)

    OpenAIRE

    Zimmermann, Harald H.

    1981-01-01

    Zimmermann beschreibt den Stand der Technik im Bereich der computergestützten Informations- und Kommunikationsprozesse im Büro (Büroautomatisierung) mit dem Schwerpunkt "Sprachverarbeitung mit dem Computer". Er geht auf das Projekt "COBIS - Labormodell eines textuellen Büro-Informations-Systems" ein und beschreibt die immer leichtere und verbesserte Integration von Kleincomputern in Informations- und Kommunikationsverbünde.

  3. Value of radiotherapy in treatment of humeroscapular periarthritis. Comparison with MRI findings; Strahlentherapie der Periarthritis humeroscapularis mit ultraharten Photonen. Vergleich mit kernspintomographischen Befunden

    Energy Technology Data Exchange (ETDEWEB)

    Zwicker, C. [Hegau Klinikum Singen (Germany). CT/MRT Abt.; Hering, M. [Hegau Klinikum Singen (Germany). Roentgenologisches Zentralinstitut; Brecht, J. [Hegau Klinikum Singen (Germany). Anaesthesiologisches Inst.; Bjoernsgaerd; Kuhne-Velte, H.J. [Klinikum Konstanz (Germany). Strahlentherapeutische Belegabt.; Kern, A. [Neurologische Praxis Singen (Germany)

    1998-09-01

    Purpose: Evaluation of MRI in radiotherapy of humeroscapular periarthritis. Patients and methods: Seventy-seven patients with humeroscapular periarthritis prospectively underwent MRI before radiotherapy. Results: Six months after radiotherapy, 34% of the patients had achieved complete pain relief, 35% major pain relief. Twenty percent had only slight improvement and 12% no improvement. Positive correlation of radiotherapy outcome and MRI findings could be shown for acute tendinitis, erosions, and complete and incomplete ruptures of the supraspinatus tendon. Conclusions: Radiotherapy is highly effective in the treatment of humeroscapular periarthritis. The indication can be improved using MRI. (orig.) [Deutsch] Fragestellung: Aussagefaehigkeit der MRT vor Strahlentherapie der Periarthritis humeroscapularis. Methodik: 77 Patienten mit Periarthritis humeroscapularis wurden prospektiv vor der Strahlentherapie mit einem Linearbeschleuniger MR-tomographisch untersucht. Ergebnisse: 6 Monate nach Beendigung der Radiatio waren 34% der Patienten beschwerdefrei. 35% zeigten eine wesentliche Besserung. 20% waren nur geringfuegig gebessert, waehrend bei 12% der Patienten die Symptomatik unveraendert fortbestand. Eine positive Korrelation der MR-Befunde mit dem Therapieerfolg bestand bei akuten Tendinitiden, Usuren sowie kompletten und inkompletten Rupturen der Supraspinatussehne. Schlussfolgerungen: Die Strahlentherapie ist neben operativen Verfahren eine weitere wertvolle Methode zur Behandlung der Periarthritis humeroscapularis. Die MRT ist zur Indikationstellung sinnvoll. (orig.)

  4. Automation technology with future perspectives. Natural gas underground storage with ABB Advant {sup trademark} OCS; Automatisierungswelt mit Zukunft. Untertageerdgasspeicherung mit ABB-Advant {sup trademark} OCS

    Energy Technology Data Exchange (ETDEWEB)

    Kerscht, S.M. [SK Automation AG, Basel (Switzerland); Katzenbach, B. [VEW Energie AG, Dortmund (Germany). Abt. Leittechnik

    1996-09-13

    The natural gas underground storage Kalle, operated by the Vereinigte Elektrizitaetswerke at Dortmund is used for the reduction of natural gas peaks. The installed control plant (PSI) consists of UNIX-work stations and server (DEC alpha series) with a modular control system. Thus the preconditions have been established in order to observe and if necessary control all VEW storage from Dortmund by means of peer-to-peer connections based on TCP/IP. In comparison to classic remote control systems, peer-to-peer connections are more flexible, more efficient and cost-effective because standard hardware can be applied. (MSK) [Deutsch] Der Untertageerdgasspeicher Kalle, der von den Vereinigten Elektrizitaetswerken mit Sitz in Dortmund betrieben wird, dient zur Reduzierung von Erdgasspitzen. Die dort installierten Leitanlage (PSI) besteht aus UNIX-Workstations und -Servern (DEC-alpha-Serie) mit einem modularen Leitsystemaufsatz. Damit sind die Voraussetzungen geschaffen, um mit Hilfe von Rechner-Rechner-Kopplungen auf Basis TCP/IP von Dortmund aus alle VEW-Speicher zu beobachten und bei Bedarf auch zu steuern. Die Rechner-Rechner-Kopplungen sind gegenueber klassischen Fernwirkstrecken wesentlich flexibler, leistungsfaehiger und letztlich auch preiswerter, da Standardhardware verwendet werden kann. (MSK)

  5. Automatic readout for nuclear emulsions in muon radiography of volcanoes

    Science.gov (United States)

    Aleksandrov, A.; Bozza, C.; Consiglio, L.; D'Ambrosio, N.; De Lellis, G.; Di Crescenzo, A.; Di Marco, N.; Kose, U.; Lauria, A.; Medinaceli, E.; Miyamoto, S.; Montesi, C.; Pupilli, F.; Rescigno, R.; Russo, A.; Sirignano, C.; Stellacci, S. M.; Strolin, P.; Tioukov, V.

    2012-04-01

    Nuclear emulsions are an effective choice in many scenarios of volcano radiography by cosmic-ray muons. They are cheap and emulsion-based detectors require no on-site power supply. Nuclear emulsion films provide sub-micrometric tracking precision and intrinsic angular accuracy better than 1 mrad. Imaging the inner structure of a volcano requires that the cosmic-ray absorption map be measured on wide angular range. High-absorption directions can be probed by allowing for large statistics, which implies a large overall flux, i.e. wide surface for the detector. A total area of the order of a few m2 is nowadays typical, thanks to the automatic readout tools originally developed for high-energy physics experiments such as CHORUS, PEANUT, OPERA. The European Scanning System is now being used to read out nuclear emulsion films exposed to cosmic rays on the side of volcanoes. The structure of the system is described in detail with respect to both hardware and software. Its present scanning speed of 20 cm2/h/side/microscope is suitable to fulfil the needs of the current exposures of nuclear emulsion films for muon radiograph, but it is worth to notice that applications in volcano imaging are among the driving forces pushing to increase the performances of the system. Preliminary results for the Unzen volcano of a joint effort by research groups in Italy and Japan show that the current system is already able to provide signal/background ratio in the range 100÷10000:1, depending on the quality cuts set in the off-line data analysis. The size of the smallest detectable structures in that experimental setup is constrained by the available statistics in the region of highest absorption to about 50 mrad, or 22 m under the top of the mountain. Another exposure is currently taking data at the Stromboli volcano. Readout of the exposed films is expected to begin in March 2012, and preliminary results will be available soon after. An effort by several universities and INFN has

  6. Inspection of Alpine glaciers with cosmic-ray muon radiography

    Science.gov (United States)

    Nishiyama, Ryuichi; Ariga, Akitaka; Ariga, Tomoko; Ereditato, Antonio; Lechmann, Alessandro; Mair, David; Scampoli, Paola; Schlunegger, Fritz; Vladymyrov, Mykhailo

    2016-04-01

    Radiography using cosmic-ray muons represents a challenging method for probing the bedrock topography beneath Alpine glaciers. We present the current status of our feasibility study at Eiger glacier, situated on the western flank of the Eiger in the Jungfrau region, Central Swiss Alps. The muon radiography is a technique that has been recently developed to investigate the internal density profiles of geoscientific targets. It is based on the measurement of the absorption of the cosmic-ray muons inside a material. Because the energy spectrum of cosmic-ray muons and the energy dependence of muon range have been studied well during the past years, the attenuation of the muon flux can be used to derive the column density, i.e. the density integrated along the muon trajectories, of geoscientific targets. This technique has recently been applied for non-invasive inspection of volcanoes, nuclear reactors, seismic faults, caves and etc. The greatest advantage of the method in the field of glacier studies is that it yields a unique solution of the density underneath a glacier without any assumption of physical properties inside the target. Large density contrasts, as expected between glacier ice (˜ 1.0g/cm3) and bedrock (˜ 2.5g/cm3), would allow us to elucidate the shape of the bedrock in high resolution. Accordingly, this technology will provide for the first time information on the bedrock surface beneath a steep and non-accessible Alpine glacier, in a complementary way with respect to other exploration methods (drilling, ground penetrating radar, seismic survey, gravity explorations and etc.). Our first aim is to demonstrate the feasibility of the method through a case study at the Eiger glacier, situated in the Central Swiss Alps. The Eiger glacier straddles the western flank of the Eiger between 3700 and 2300 m above sea level (a.s.l.). The glacier has shortened by about 150 m during the past 30 years in response to the ongoing global warming, causing a concern for

  7. Imaging suspected cervical spine injury: Plain radiography or computed tomography? Systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Cain, Gavin [Diagnostic Radiographer, Colchester Hospital University NHS Foundation Trust, Colchester General Hospital, Turner Road, Colchester, CO4 5JL Essex (United Kingdom)], E-mail: gavincain8@hotmail.com; Shepherdson, Jane; Elliott, Vicki; Svensson, Jon [Faculty of Health and Social Care, Anglia Ruskin University, East Road, Cambridge, CB1 9PT Cambridgeshire (United Kingdom); Brennan, Patrick [UCD School of Medicine and Medical Sciences, Health Science Building, Belfield, Dublin 4 (Ireland)

    2010-02-15

    Aim: (1) to establish which modality offers the greatest accuracy in the detection of cervical spine injury (CSI) Following trauma: plain radiography or computed tomography (CT), and (2) make an evidence-based recommendation for the initial imaging modality of choice. Method: A systematic literature review was performed to identify primary research studies which compare the diagnostic accuracy of plain radiography and CT with the results of a reference standard in the detection of CSI. A search of MEDLINE, EMBASE, CINAHL, Science Direct and Pubmed Central databases was conducted. Results: Ten studies were identified. Critical appraisal identified limitations among all studies. There was heterogeneity in the sensitivity estimates for plain radiography, whereas estimates for CT were consistently high. Examination of the reported sensitivities shows that CT outperforms plain radiography in the detection of CSI. Conclusion: CT is superior to plain radiography in the detection of CSI. However, the optimal imaging strategy depends on the patients' relative risk of injury. If at high-risk cervical CT is indicated. If at low-risk the increased cost and radiation exposure mean that screening CT may not be warranted, good-quality plain radiographs are sufficient.

  8. General Dental Practitioners’ Concept towards Using Radiography and Apex-Locators in Endodontics

    Science.gov (United States)

    Raoof, Maryam; Heidaripour, Maryam; Shahravan, Arash; Haghani, Jahangir; Afkham, Arash; Razifar, Mahsa; Mohammadizadeh, Sakineh

    2014-01-01

    Introduction: Despite being the gold standard as well as a routine technique in endodontics, radiographic working length (WL) determination owns many drawbacks. Electronic apex-locators (EALs) are recommended to complement radiographies. The aim of this study was to evaluate the perceptions of Iranian general dental practitioners (GDPs) towards using radiography and EAL. Methods and Materials: Three hundred and ninety one GDPs attending the 53th Iranian Dental Association Congress completed a questionnaire focusing on the use of radiography and EALs during the various stages of root canal treatment. The data was analyzed with the chi-square test with the level of significance set at 0.05. The results were then calculated as frequencies and percentages. Results: More than half of the GDPs reported using radiographs as the sole method for WL determination. A total of 30.4% of the practitioners were using the combined approach during root canal therapy of a single-rooted tooth, while 38.9% used this method in multi-rooted teeth. Approximately half of the respondents would not order follow-up radiographies after root canal treatment. Conclusion: Radiography continues to be the most common method for WL determination in Iran. PMID:25386209

  9. Use of ultrasound, color Doppler imaging and radiography to monitor periapical healing after endodontic surgery.

    Science.gov (United States)

    Tikku, Aseem P; Kumar, Sunil; Loomba, Kapil; Chandra, Anil; Verma, Promila; Aggarwal, Renu

    2010-09-01

    This study evaluated the effectiveness of ultrasound, color Doppler imaging and conventional radiography in monitoring the post-surgical healing of periapical lesions of endodontic origin. Fifteen patients who underwent periapical surgery for endodontic pathology were randomly selected. In all patients, periapical lesions were evaluated preoperatively using ultrasound, color Doppler imaging and conventional radiography, to analyze characteristics such as size, shape and dimensions. On radiographic evaluation, dimensions were measured in the superoinferior and mesiodistal direction using image-analysis software. Ultrasound evaluation was used to measure the changes in shape and dimensions on the anteroposterior, superoinferior, and mesiodistal planes. Color Doppler imaging was used to detect the blood-flow velocity. Postoperative healing was monitored in all patients at 1 week and 6 months by using ultrasound and color Doppler imaging, together with conventional radiography. The findings were then analyzed to evaluate the effectiveness of the 3 imaging techniques. At 6 months, ultrasound and color Doppler imaging were significantly better than conventional radiography in detecting changes in the healing of hard tissue at the surgical site (P < 0.004). This study demonstrates that ultrasound and color Doppler imaging have the potential to supplement conventional radiography in monitoring the post-surgical healing of periapical lesions of endodontic origin.

  10. Final-year diagnostic radiography students' perception of role models within the profession.

    Science.gov (United States)

    Conway, Alinya; Lewis, Sarah; Robinson, John

    2008-01-01

    Within a clinical education setting, the value of role models and prescribed mentors can be seen as an important influence in shaping the student's future as a diagnostic radiographer. A study was undertaken to create a new understanding of how diagnostic radiography students perceive role models and professional behavior in the workforce. The study aimed to determine the impact of clinical education in determining modeling expectations, role model identification and attributes, and the integration of academic education and "hands-on" clinical practice in preparing diagnostic radiography students to enter the workplace. Thirteen final-year (third-year) diagnostic radiography students completed an hour-long interview regarding their experiences and perceptions of role models while on clinical placement. The key concepts that emerged illustrated that students gravitate toward radiographers who enjoy sharing practical experiences with students and are good communicators. Unique to diagnostic radiography, students made distinctions about the presence of role models in private versus public service delivery. This study gives insight to clinical educators in diagnostic radiography and wider allied health into how students perceive role models, interact with preceptors, and combine real-life experiences with formal learning.

  11. Productivity improvements with a direct digital radiography system integrated with PACS

    Science.gov (United States)

    Jeromin, Lothar S.; Lee, Denny L. Y.; Palecki, Eugene F.; Wolff, David P.

    1996-05-01

    The productivity-improving features of a direct digital radiography system for projection radiography are introduced and the integration of the system with PACS is discussed. A flat panel digital array, an array controller, and a system controller with video monitor and standard interface to a local or wide area communications network are the main components of the direct digital radiography system of which prototypes have been built and tested in laboratory settings. When used in radiology room for projection radiography, the digital array converts x-ray photons into digital image data and makes the data available immediately for display on a video monitor for the technologist's review. Upon the technologist's acceptance of the image, an industry-standard network allows the transmission of the image to a workstation where additional image processing can be performed and where the image can be viewed on a high resolution display by the radiologist. If so desired, the image may be routed to a laser printer, digital mass storage medium, or to a PACS communication interface. By connecting the direct digital radiography system with a PACS network, radiographs may be shared electronically like images of other digital modalities. In this scenario, productivity improvements would come mainly from shorter patient exams as a result of the immediate availability of the review images, wider exposure latitude and ease of handling of the digital array, and from the electronic transport, storage and retrieval of image files and patient data in a PACS environment.

  12. Comparison of panoramic radiography and CBCT to identify maxillary posterior roots invading the maxillary sinus.

    Science.gov (United States)

    Lopes, Luciana J; Gamba, Thiago O; Bertinato, João V J; Freitas, Deborah Q

    Given the limitations of panoramic radiography for assessing topographic relationship of maxillary teeth with sinus floor, the purpose of this study was to assess signs on panoramic radiography that could predict root protrusion into the sinus. A total of 46 individuals (330 maxillary posterior teeth) who underwent panoramic radiography and CBCT were enrolled. The relationship between the posterior teeth and the maxillary sinus and panoramic radiography signs (projection of the root apices, interruption of the maxillary sinus floor, lamina dura, darkening in the root apices, and superiorly curving sinus floor enveloping the associated tooth root) associated with protrusion of root apices into the sinus were evaluated. There were differences between the imaging modalities about the positioning of the root apices regarding the sinus (p sinus floor on panoramic radiography were predictors for the root protrusion (p  0.05). The root projection into the sinus and the interruption of the sinus floor are indicative signs of root protrusion into the sinus on CBCT.

  13. Factors associated with the goal commitment of radiography departments' staff in organizational change

    Energy Technology Data Exchange (ETDEWEB)

    Groenroos, Eija [Helsinki Metropolia University of Applied Sciences, Degree Programme in Radiography and Radiotherapy, Mannerheimintie 172, 00300 Helsinki (Finland)], E-mail: eija.gronroos@metropolia.fi; Pajukari, Arja [MHS, Hus-Roentgen, PL 809, 00029 Hus (Finland)], E-mail: arja.pajukari@hus.fi; Matinheikki-Kokko, Kaija [Helsinki Metropolia University of Applied Sciences, Mannerheimintie 172, 00300 Helsinki (Finland)

    2009-11-15

    Purpose: The aim of the study is to examine factors associated with the goal commitment of radiography departments' staff. The associations studied are (1) organizational change, (2) work-related factors, (3) psychosocial work environment, and (4) intention to leave. Method: The follow-up study was performed between 2005 and 2007 in co-operation with 10 radiography departments of two Finnish municipalities. In 2005 the response rate was 60% (n = 97/163) and in 2007 it was 49% (n = 73/150). Results: The goal commitment had dropped during the organizational change from 3.96 in 2005 to 3.60 in 2007 (scale 1-5) (p = 0.001). Best predictors for the goal commitment of radiography departments' staff were having children (OR 4.4) and perceiving functional environment clearly (OR 2.6). Correlation between the goal commitment and intention to leave of the staff was -0.32 (p = 0.01). Conclusion: From the viewpoint of the commitment of the radiography departments' staff, the trend of uniting quite independent health care units into larger entities seems not to be beneficial. This study reveals that commitment to one's work unit is most of all a question of stability and job security. This is a fact the leadership of the radiography departments should take into account, appreciate and support to assure the tenure and productivity of their workforce.

  14. An evaluation of author productivity in international radiography journals 2004–2011

    Energy Technology Data Exchange (ETDEWEB)

    Snaith, Beverly A [Radiology Department, Mid Yorkshire Hospitals NHS Trust, Pinderfields Hospital, Aberford Road (United Kingdom)

    2013-09-15

    Radiography, the allied health profession, has changed beyond recognition over the last century; however, in academic terms radiography is a relatively young profession. It is therefore still establishing its professional knowledge base. This article uses peer-review author productivity distribution to evaluate its scholarly maturity. Four peer-reviewed journals in medical radiation sciences were examined over an 8-year period (2004–2011) and author productivity was compared to Lotka's law. Further analysis of the most prolific authors provided an evaluation of their characteristics. The 1306 unique authors contributed 835 articles during the study period. Of these, 1012 (77.5%) contributed only one article to the journals studied, with an inverse power relationship of author productivity. At the 0.1 level of significance, radiography does not fit Lotka's law (n = −2.334; c = 0.712; D{sub max} = 0.0627; Critical threshold = 0.0337). There was a significant correlation between the most prolific authors and collaboration (P = 0.002), although variation was noted in author discipline and location. The results of this study add to the discussion of radiography scholarship and demonstrate that the radiography authors have similar productivity distribution to other professions, but do not follow Lotka's law.

  15. Analysis of sculptures using XRF and X-ray radiography

    Science.gov (United States)

    Calza, C.; Oliveira, D. F.; Freitas, R. P.; Rocha, H. S.; Nascimento, J. R.; Lopes, R. T.

    2015-11-01

    This work reports the analysis of two sacred images on polychrome wood using X-ray Radiography and Energy Dispersive X-Ray Fluorescence. The first case is the analysis of a sculpture portraying Saint Sebastian, the patron saint of Rio de Janeiro, which is considered the second most ancient sacred image of Brazil. This sculpture was made in Portugal and was transported to Brazil by Estácio Sá, founder of the city of Rio de Janeiro, in 1565. Nowadays, it is located on the main altar of the Church of Capuchin Friars. The second case is the analysis of a sculpture representing Our Lady of Conception, which is located in the D. João VI Museum (EBA/UFRJ, Rio de Janeiro). The objective of these analyses was to evaluate the general conditions of the sculptures, identifying possible problems and internal damages, areas that revealed signs of previous retouchings and the materials and pigments employed by the artists, in order to assist its restoration procedures. EDXRF measurements were carried out with a portable system, developed at the Nuclear Instrumentation Laboratory, consisting of a Si-PIN XR-100CR detector from Amptek and an Oxford TF3005 X-ray tube with W anode. An X-ray source, a CR System GE CR50P and IP detectors were used to perform the radiographs. The XRF analysis of the sculptures identified the original pigments in both cases and the radiographic images revealed details of the manufacture; restored regions; extensive use of lead white; presence of cracks on the wood; use of nails and spikes, etc.

  16. Image quality dependence on image processing software in computed radiography

    Directory of Open Access Journals (Sweden)

    Lourens Jochemus Strauss

    2012-06-01

    Full Text Available Background. Image post-processing gives computed radiography (CR a considerable advantage over film-screen systems. After digitisation of information from CR plates, data are routinely processed using manufacturer-specific software. Agfa CR readers use MUSICA software, and an upgrade with significantly different image appearance was recently released: MUSICA2. Aim. This study quantitatively compares the image quality of images acquired without post-processing (flatfield with images processed using these two software packages. Methods. Four aspects of image quality were evaluated. An aluminium step-wedge was imaged using constant mA at tube voltages varying from 40 to 117kV. Signal-to-noise ratios (SNRs and contrast-to-noise Ratios (CNRs were calculated from all steps. Contrast variation with object size was evaluated with visual assessment of images of a Perspex contrast-detail phantom, and an image quality figure (IQF was calculated. Resolution was assessed using modulation transfer functions (MTFs. Results. SNRs for MUSICA2 were generally higher than the other two methods. The CNRs were comparable between the two software versions, although MUSICA2 had slightly higher values at lower kV. The flatfield CNR values were better than those for the processed images. All images showed a decrease in CNRs with tube voltage. The contrast-detail measurements showed that both MUSICA programmes improved the contrast of smaller objects. MUSICA2 was found to give the lowest (best IQF; MTF measurements confirmed this, with values at 3.5 lp/mm of 10% for MUSICA2, 8% for MUSICA and 5% for flatfield. Conclusion. Both MUSICA software packages produced images with better contrast resolution than unprocessed images. MUSICA2 has slightly improved image quality than MUSICA.

  17. Femoral neck radiography: effect of flexion on visualization

    Energy Technology Data Exchange (ETDEWEB)

    Garry, S.C. [Univ. of Alberta, Dept. of Radiology and Diagnostic Imaging, Walter C Mackenzie Health Sciences Centre, Edmonton, Alberta (Canada); Jhangri, G.S. [Univ. of Alberta, Dept. Public Health Sciences, Edmonton, Alberta (Canada); Lambert, R.G.W. [Univ. of Alberta, Dept.of Radiology and Diagnostic Imaging, Walter C Mackenzie Health Sciences Centre, Edmonton, Alberta (Canada)]. E-mail: rglamber@cha.ab.ca

    2005-06-15

    To determine whether flexion improves radiographic visualization of the femoral neck when the femur is externally rotated. Five human femora, with varying neck-shaft and anteversion angles, were measured and immobilized. Degree of flexion required to bring the femoral neck horizontal was measured, varying the rotation. Next, one bone was radiographed in 16 positions, varying rotation in 15{sup o} and flexion in 10{sup o} increments. Radiographs were presented in randomized blinded fashion to 15 staff radiologists for scoring of femoral neck visualization. Following this, all 5 bones were radiographed in 4 positions of rotation and at 0{sup o} and 20{sup o} flexion, and blinded randomized review of radiographs was repeated. Comparisons between angles and rotations were made using the Mann-Whitney test. The flexion angle required to bring the long axis of the femoral neck horizontal correlated directly with the degree of external rotation ({rho} < 0.05). Visualization of the femoral neck in the extended position progressively deteriorated from 15{sup o} internal rotation to 30{sup o} external rotation ({rho} <0.01). However, when 20{sup o} flexion was applied to bones in external rotation, visualization significantly improved at 15{sup o} ({rho} <0.05) and 30{sup o} ({rho} <0.01). Flexion of the externally rotated femur can bring the femoral neck into horizontal alignment, and a relatively small amount (20{sup o}) of flexion can significantly improve radiographic visualization. This manoeuvre could be useful for radiography of the femoral neck when initial radiographs are inadequate because of external rotation of the leg. (author)

  18. Water Migration and Swelling in Bentonite Quantified using Neutron Radiography

    Science.gov (United States)

    Vial, A.; DiStefano, V. H.; Perfect, E.; Hale, R. E.; Anovitz, L. M.; McFarlane, J.

    2016-12-01

    Permanent disposal of radioactive waste remains a critical challenge for the nation's energy future. All disposal system concepts include interfaces between engineered systems and natural materials requiring extensive characterization. Bentonite is often used to buffer subsurface disposal systems from geologic media containing ground water. Bentonite characterization experiments were carried out using the CG-1D neutron imaging beam line at Oak Ridge National Laboratory. Dry bentonite was packed into vertically-oriented aluminum cylinders. Water was ponded on the top surface of each packed cylinder. Images were acquired at 2 min intervals using dynamic neutron radiography. The detector consisted of stacked neutron sensitive microchannel plates above a quad Timepix readout with a 28 x 28 mm2 field of view. The spatial resolution of the detector was 55 μm. Raw neutron radiographs were imported into ImageJ and normalized with respect to the initial completely dry state. The wetting process was 1-dimensional, and vertical intensity profiles were computed by averaging pixel rows. The vertical distance between the clay-water interface and the wetting front could then be determined as a function of time. Depth of water infiltration increased linearly with the square root of time, yielding a sorptivity value of 0.75 (± 0.070) mm/min0.5. Swelling occurred in the form of upward movement of clay particles into the ponded water over time. The resulting low density assemblage was discernable by normalizing the raw profiles with respect to the intensity profile immediately after ponding. The packed clay-water interface was clearly visible in the normalized profiles, and swelling was quantified as the height of the low density assemblage above the original interface. Swelling occurred as a linear function of time, at a rate of 0.054 (± 0.020) mm/min. Further experiments of this type are planned under variable temperature and pressure regimes applicable to subsurface

  19. Distinguishing materials in inspected objects by digital radiography

    Science.gov (United States)

    Ryzhikov, V.; Lysetska, O.; Opolonin, A.; Danilenko, V.; Galkin, S.; Voronkin, E.; Kostyukevich, S. A.

    2005-08-01

    We used detector arrays of types "scintillator-photodiode" (S-PD) and scintillator-photoreceiving device (PRD). In non-destructive testing systems using S-PD arrays it is possible to use scintillators of different atomic number and density, which allows functioning in the energy range from 20 keV to 10 MeV, i.e., steel equivalent thickness I from 100μm to 300mm. For different objects and different purposes, different types of detector arrays and methods of control can be recommended. Results of experimental studies of detector arrays S-PD and S-PRD used for X-ray digital radiography have shown that there exist further possibilities to increase spatial resolution of this system for up to 2-3 line pairs per mm. It was investigated experimental results with used two array detectors for low-energy and high - energy detections (HED and LED). It is show in principle to distinguish not only organic from inorganic materials, but so as safety organic from explosive. Our aim was to show (theoretically and experimentally) that is could be possible to substantially increase the accuracy of separation of substances in the inspected object by their atomic number, as well as to increase the sensitivity of the method as a whole by using a multi-energy approach and detectors that have substantially different sensibility in the low-and high-energy range of the X-ray emitter spectrum. It was show the possibility to distinct materials with effective atomic number difference about 10-15%. It can be used in inspection systems, including anti-terrorist activities, in technical diagnostics, medicine.

  20. Optimisation of computed radiography systems for chest imaging

    Energy Technology Data Exchange (ETDEWEB)

    Alzimami, K. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)], E-mail: k.alzimami@surrey.ac.uk; Sassi, S. [Royal Marsden NHS Foundation Trust, Sutton, Surrey SM2 5PT (United Kingdom); Alkhorayef, M. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom); Britten, A.J. [Department of Medical Physics, St George' s Hospital, London SW17 0QT (United Kingdom); Spyrou, N.M. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2009-03-01

    The main thrust of this study is to investigate methods of optimising the radiation dose-image quality relationship in computed radiography (CR) systems for chest imaging. Specifically, this study investigates the possibility of reducing the patient radiation exposure through an optimal selection of tube filtration, exposure parameters and air gap technique, in parallel with a study of the image quality, particularly low contrast detail detectability, signal-to-noise ratio (SNR) and scatter fraction (SF). The CDRAD phantom was used to assess the quality of the CR images. Tissue equivalent Polystyrene blocks were placed in the front of the phantom as scattering material with thicknesses of 5 and 15 cm to simulate an adult chest and heart/diaphragm regions, respectively. A series of exposure techniques were used, including Cu filtration with various thicknesses of Cu in the presence and absence of an air gap, whilst the exposure was kept as constant as possible throughout. The estimated patient effective dose and skin entrance dose were calculated using the NRPB-SR262 X-ray dose calculation software. The results have shown that the low contrast-detail detectability in the lung and the heart/diaphragm regions improves when using an air gap and no Cu filtration, particularly at low kilovoltage (kVp). However, there is no significant difference in low contrast-detail in the absence or presence of a 0.2 mm Cu filtration. SF values for the lung and heart regions decrease when using both, the air gap technique and a 0.2 mm Cu filtration, particularly at low kVp. SNR values for the lung and heart regions improve when using a small Cu thickness. In conclusion, this investigation has shown that the quality of chest CR images could be improved by using an air gap technique and a 0.2 mm Cu filtration at low kVp, particularly at 99 kVp.