WorldWideScience

Sample records for minimum detection limits

  1. Minimum detection limit and spatial resolution of thin-sample field-emission electron probe microanalysis

    International Nuclear Information System (INIS)

    Kubo, Yugo; Hamada, Kotaro; Urano, Akira

    2013-01-01

    The minimum detection limit and spatial resolution for a thinned semiconductor sample were determined by electron probe microanalysis (EPMA) using a Schottky field emission (FE) electron gun and wavelength dispersive X-ray spectrometry. Comparison of the FE-EPMA results with those obtained using energy dispersive X-ray spectrometry in conjunction with scanning transmission electron microscopy, confirmed that FE-EPMA is largely superior in terms of detection sensitivity. Thin-sample FE-EPMA is demonstrated as a very effective method for high resolution, high sensitivity analysis in a laboratory environment because a high probe current and high signal-to-noise ratio can be achieved. - Highlights: • Minimum detection limit and spatial resolution determined for FE-EPMA. • Detection sensitivity of FE-EPMA greatly superior to that of STEM-EDX. • Minimum detection limit and spatial resolution controllable by probe current

  2. Preliminary minimum detectable limit measurements in 208-L drums for selected actinide isotopes in mock-waste matrices

    International Nuclear Information System (INIS)

    Camp, D.C.; Wang, Tzu-Fang; Martz, H.E.

    1992-01-01

    Preliminary minimum detectable levels (MDLS) of selected actinide isotopes have been determined in full-scale, 55-gallon drums filled with a range of mock-waste materials from combustibles (0.14 g/CM 3 ) to sand (1.7 g/CM 3 ). Measurements were recorded from 100 to 10,000 seconds with selected actinide sources located in these drums at an edge position, on the center axis of a drum and midway between these two positions. Measurements were also made with a 166 Ho source to evaluate the attenuation of these mock-matrix materials as a function of energy. By knowing where the source activity is located within a drum, our preliminary results show that a simply collimated 90% HPGE detector can differentiate between TRU (>100 nCi/g) and LLW amounts of 239 Pu in only 100s of measurement time and with sufficient accuracy in both low and medium density, low Z materials. Other actinides measured so far include 235 U, 241 Am, and 244 Cm. These measurements begin to establish the probable MDLs achievable in the nondestructive assays of real waste drums when using active and passive CT. How future measurements may differ from these preliminary measurements is also discussed

  3. Minimum Delay Moving Object Detection

    KAUST Repository

    Lao, Dong

    2017-11-09

    We present a general framework and method for detection of an object in a video based on apparent motion. The object moves relative to background motion at some unknown time in the video, and the goal is to detect and segment the object as soon it moves in an online manner. Due to unreliability of motion between frames, more than two frames are needed to reliably detect the object. Our method is designed to detect the object(s) with minimum delay, i.e., frames after the object moves, constraining the false alarms. Experiments on a new extensive dataset for moving object detection show that our method achieves less delay for all false alarm constraints than existing state-of-the-art.

  4. Minimum Delay Moving Object Detection

    KAUST Repository

    Lao, Dong

    2017-01-08

    We present a general framework and method for detection of an object in a video based on apparent motion. The object moves relative to background motion at some unknown time in the video, and the goal is to detect and segment the object as soon it moves in an online manner. Due to unreliability of motion between frames, more than two frames are needed to reliably detect the object. Our method is designed to detect the object(s) with minimum delay, i.e., frames after the object moves, constraining the false alarms. Experiments on a new extensive dataset for moving object detection show that our method achieves less delay for all false alarm constraints than existing state-of-the-art.

  5. Minimum Delay Moving Object Detection

    KAUST Repository

    Lao, Dong; Sundaramoorthi, Ganesh

    2017-01-01

    We present a general framework and method for detection of an object in a video based on apparent motion. The object moves relative to background motion at some unknown time in the video, and the goal is to detect and segment the object as soon it moves in an online manner. Due to unreliability of motion between frames, more than two frames are needed to reliably detect the object. Our method is designed to detect the object(s) with minimum delay, i.e., frames after the object moves, constraining the false alarms. Experiments on a new extensive dataset for moving object detection show that our method achieves less delay for all false alarm constraints than existing state-of-the-art.

  6. Minimum Delay Moving Object Detection

    KAUST Repository

    Lao, Dong

    2017-05-14

    This thesis presents a general framework and method for detection of an object in a video based on apparent motion. The object moves, at some unknown time, differently than the “background” motion, which can be induced from camera motion. The goal of proposed method is to detect and segment the object as soon it moves in an online manner. Since motion estimation can be unreliable between frames, more than two frames are needed to reliably detect the object. Observing more frames before declaring a detection may lead to a more accurate detection and segmentation, since more motion may be observed leading to a stronger motion cue. However, this leads to greater delay. The proposed method is designed to detect the object(s) with minimum delay, i.e., frames after the object moves, constraining the false alarms, defined as declarations of detection before the object moves or incorrect or inaccurate segmentation at the detection time. Experiments on a new extensive dataset for moving object detection show that our method achieves less delay for all false alarm constraints than existing state-of-the-art.

  7. Minimum Delay Moving Object Detection

    KAUST Repository

    Lao, Dong; Sundaramoorthi, Ganesh

    2017-01-01

    We present a general framework and method for detection of an object in a video based on apparent motion. The object moves relative to background motion at some unknown time in the video, and the goal is to detect and segment the object as soon

  8. Minimum Delay Moving Object Detection

    KAUST Repository

    Lao, Dong

    2017-01-01

    This thesis presents a general framework and method for detection of an object in a video based on apparent motion. The object moves, at some unknown time, differently than the “background” motion, which can be induced from camera motion. The goal

  9. Activation analysis. Detection limits

    International Nuclear Information System (INIS)

    Revel, G.

    1999-01-01

    Numerical data and limits of detection related to the four irradiation modes, often used in activation analysis (reactor neutrons, 14 MeV neutrons, photon gamma and charged particles) are presented here. The technical presentation of the activation analysis is detailed in the paper P 2565 of Techniques de l'Ingenieur. (A.L.B.)

  10. What value, detection limits

    International Nuclear Information System (INIS)

    Currie, L.A.

    1986-01-01

    Specific approaches and applications of LLD's to nuclear and ''nuclear-related'' measurements are presented in connection with work undertaken for the U.S. Nuclear Regulatory Commission and the International Atomic Energy Agency. In this work, special attention was given to assumptions and potential error sources, as well as to different types of analysis. For the former, the authors considered random and systematic error associated with the blank and the calibration and sample preparation processes, as well as issues relating to the nature of the random error distributions. Analysis types considered included continuous monitoring, ''simple counting'' involving scalar quantities, and spectrum fitting involving data vectors. The investigation of data matrices and multivariate analysis is also described. The most important conclusions derived from this study are: that there is a significant lack of communication and compatibility resulting from diverse terminology and conceptual bases - including no-basis ''ad hoc'' definitions; that the distinction between detection decisions and detection limits is frequently lost sight of; and that quite erroneous LOD estimates follow from inadequate consideration of the actual variability of the blank, and systematic error associated with the blank, the calibration-recovery factor, matrix effects, and ''black box'' data reduction models

  11. Verification of Minimum Detectable Activity for Radiological Threat Source Search

    Science.gov (United States)

    Gardiner, Hannah; Myjak, Mitchell; Baciak, James; Detwiler, Rebecca; Seifert, Carolyn

    2015-10-01

    The Department of Homeland Security's Domestic Nuclear Detection Office is working to develop advanced technologies that will improve the ability to detect, localize, and identify radiological and nuclear sources from airborne platforms. The Airborne Radiological Enhanced-sensor System (ARES) program is developing advanced data fusion algorithms for analyzing data from a helicopter-mounted radiation detector. This detector platform provides a rapid, wide-area assessment of radiological conditions at ground level. The NSCRAD (Nuisance-rejection Spectral Comparison Ratios for Anomaly Detection) algorithm was developed to distinguish low-count sources of interest from benign naturally occurring radiation and irrelevant nuisance sources. It uses a number of broad, overlapping regions of interest to statistically compare each newly measured spectrum with the current estimate for the background to identify anomalies. We recently developed a method to estimate the minimum detectable activity (MDA) of NSCRAD in real time. We present this method here and report on the MDA verification using both laboratory measurements and simulated injects on measured backgrounds at or near the detection limits. This work is supported by the US Department of Homeland Security, Domestic Nuclear Detection Office, under competitively awarded contract/IAA HSHQDC-12-X-00376. This support does not constitute an express or implied endorsement on the part of the Gov't.

  12. Detection of minimum-ionizing particles in hydrogenated amorphous silicon

    International Nuclear Information System (INIS)

    Kaplan, S.N.; Fujieda, I.; Perez-Mendez, V.; Qureshi, S.; Ward, W.; Street, R.A.

    1987-09-01

    Based on previously-reported results of the successful detection of alpha particles and 1- and 2-MeV protons with hydrogenated amorphous silicon (a-Si : H) diodes, detection of a single minimum-ionizing particle will require a total sensitive thickness of approximately 100 to 150 μm, either in the form of a single thick diode, or as a stack of several thinner diodes. Signal saturation at high dE/dx makes it necessary to simulate minimum ionization in order to evaluate present detectors. Two techniques, using pulsed infrared light, and pulsed x-rays, give single-pulse signals large enough for direct measurements. A third, using beta rays, requires multiple-transit signal averaging to produce signals measurable above noise. Signal amplitudes from the a-Si : H limit at 60% of the signal size from Si crystals extrapolated to the same thickness. This is consistent with an a-Si : H radiation ionization energy, W = 6 eV/electron-hole pair. Beta-ray signals are observed at the expected amplitude

  13. Maximum/minimum asymmetric rod detection

    International Nuclear Information System (INIS)

    Huston, J.T.

    1990-01-01

    This patent describes a system for determining the relative position of each control rod within a control rod group in a nuclear reactor. The control rod group having at least three control rods therein. It comprises: means for producing a signal representative of a position of each control rod within the control rod group in the nuclear reactor; means for establishing a signal representative of the highest position of a control rod in the control rod group in the nuclear reactor; means for establishing a signal representative of the lowest position of a control rod in the control rod group in the nuclear reactor; means for determining a difference between the signal representative of the position of the highest control rod and the signal representative of the position of the lowest control rod; means for establishing a predetermined limit for the difference between the signal representative of the position of the highest control rod and the signal representative of the position of the lowest control rod; and means for comparing the difference between the signals with the predetermined limit. The comparing means producing an output signal when the difference between the signals exceeds the predetermined limit

  14. Minimum Detectable Activity for Tomographic Gamma Scanning System

    Energy Technology Data Exchange (ETDEWEB)

    Venkataraman, Ram [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Smith, Susan [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Kirkpatrick, J. M. [Canberra Industries (AREVA BDNM), Meriden, CT (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-01-01

    For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographic Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each “view” is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities

  15. Minimum ionizing particle detection using amorphous silicon diodes

    Energy Technology Data Exchange (ETDEWEB)

    Xi, J.; Hollingsworth, R.E.; Buitrago, R.H. (Glasstech Solar, Inc., Wheat Ridge, CO (USA)); Oakley, D.; Cumalat, J.P.; Nauenberg, U. (Colorado Univ., Boulder (USA). Dept. of Physics); McNeil, J.A. (Colorado School of Mines, Golden (USA). Dept. of Physics); Anderson, D.F. (Fermi National Accelerator Lab., Batavia, IL (USA)); Perez-Mendez, V. (Lawrence Berkeley Lab., CA (USA))

    1991-03-01

    Hydrogenated amorphous silicon pin diodes have been used to detect minimum ionizing electrons with a pulse height signal-to-noise ratio exceeding 3. A distinct signal was seen for shaping times from 100 to 3000 ns. The devices used had a 54 {mu}m thick intrinsic layer and an active area of 0.1 cm{sup 2}. The maximum signal was 3200 electrons with a noise width of 950 electrons for a shaping time of 250 ns. (orig.).

  16. 22 CFR 151.4 - Minimum limits for motor vehicle insurance.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Minimum limits for motor vehicle insurance. 151.4 Section 151.4 Foreign Relations DEPARTMENT OF STATE DIPLOMATIC PRIVILEGES AND IMMUNITIES COMPULSORY LIABILITY INSURANCE FOR DIPLOMATIC MISSIONS AND PERSONNEL § 151.4 Minimum limits for motor vehicle...

  17. Minimum detectable gas concentration performance evaluation method for gas leak infrared imaging detection systems.

    Science.gov (United States)

    Zhang, Xu; Jin, Weiqi; Li, Jiakun; Wang, Xia; Li, Shuo

    2017-04-01

    Thermal imaging technology is an effective means of detecting hazardous gas leaks. Much attention has been paid to evaluation of the performance of gas leak infrared imaging detection systems due to several potential applications. The minimum resolvable temperature difference (MRTD) and the minimum detectable temperature difference (MDTD) are commonly used as the main indicators of thermal imaging system performance. This paper establishes a minimum detectable gas concentration (MDGC) performance evaluation model based on the definition and derivation of MDTD. We proposed the direct calculation and equivalent calculation method of MDGC based on the MDTD measurement system. We build an experimental MDGC measurement system, which indicates the MDGC model can describe the detection performance of a thermal imaging system to typical gases. The direct calculation, equivalent calculation, and direct measurement results are consistent. The MDGC and the minimum resolvable gas concentration (MRGC) model can effectively describe the performance of "detection" and "spatial detail resolution" of thermal imaging systems to gas leak, respectively, and constitute the main performance indicators of gas leak detection systems.

  18. Minimum detectable activities of contamination control survey equipment

    International Nuclear Information System (INIS)

    Goles, R.W.; Baumann, B.L.; Johnson, M.L.

    1991-08-01

    The Instrumentation ampersand External Dosimetry (I ampersand ED) Section of the Health Physics Department at the Pacific Northwest Laboratory (PNL) has performed a series of tests to determine the ability of portable survey instruments used at Hanford to detect radioactive contamination at levels required by DOE 5480.11. This semi-empirical study combines instrumental, statistical, and human factors as necessary to derive operational detection limits. These threshold detection values have been compared to existing contamination control requirements, and detection deficiencies have been identified when present. Portable survey instruments used on the Hanford Site identify the presence of radioactive surface contamination based on the detection of α-, β-, γ-, and/or x-radiation. However, except in some unique circumstances, most contamination monitors in use at Hanford are configured to detect either α-radiation alone or β- and γ-radiation together. Testing was therefore conducted on only these two categories of radiation detection devices. Nevertheless, many of the results obtained are generally applicable to all survey instruments, allowing performance evaluations to be extended to monitoring devices which are exclusively γ- and/or x-ray- sensitive. 6 figs., 2 tabs

  19. Material limitations on the detection limit in refractometry.

    Science.gov (United States)

    Skafte-Pedersen, Peder; Nunes, Pedro S; Xiao, Sanshui; Mortensen, Niels Asger

    2009-01-01

    We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η, with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and filling fractions into account, the detection limit declines. As an example we discuss the fundamental limits of silicon-based high-Q resonators, such as photonic crystal resonators, for sensing in a bio-liquid environment, such as a water buffer. In the transparency window (λ ≳ 1100 nm) of silicon the detection limit becomes almost independent on the filling fraction, while in the visible, the detection limit depends strongly on the filling fraction because the silicon absorbs strongly.

  20. Material Limitations on the Detection Limit in Refractometry

    Directory of Open Access Journals (Sweden)

    Niels Asger Mortensen

    2009-10-01

    Full Text Available We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and filling fractions into account, the detection limit declines. As an example we discuss the fundamental limits of silicon-based high-Q resonators, such as photonic crystal resonators, for sensing in a bio-liquid environment, such as a water buffer. In the transparency window (λ ≳ 1100 nm of silicon the detection limit becomes almost independent on the filling fraction, while in the visible, the detection limit depends strongly on the filling fraction because the silicon absorbs strongly.

  1. Detection Limits for Nanoscale Biosensors

    National Research Council Canada - National Science Library

    Sheehan, Paul E; Whitman, Lloyd J

    2005-01-01

    We examine through analytical calculations and finite element simulations how the detection efficiency of disk and wire-like biosensors in unmixed fluids varies with size from the micrometer to nanometer scales...

  2. Material limitations on the detection limit in refractometry

    DEFF Research Database (Denmark)

    Skafte-Pedersen, Peder; Nunes, Pedro; Xiao, Sanshui

    2009-01-01

    We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and...

  3. Material Limitations on the Detection Limit in Refractometry

    OpenAIRE

    Skafte-Pedersen, Peder; Nunes, Pedro S.; Xiao, Sanshui; Mortensen, Niels Asger

    2009-01-01

    We discuss the detection limit for refractometric sensors relying on high-Q optical cavities and show that the ultimate classical detection limit is given by min {Δn} ≳ η with n + iη being the complex refractive index of the material under refractometric investigation. Taking finite Q factors and filling fractions into account, the detection limit declines. As an example we discuss the fundamental limits of silicon-based high-Q resonators, such as photonic crystal resonators, for sensing in a...

  4. Signal detection without finite-energy limits to quantum resolution

    OpenAIRE

    Luis Aina, Alfredo

    2013-01-01

    We show that there are extremely simple signal detection schemes where the finiteness of energy resources places no limit on the resolution. On the contrary, larger resolution can be obtained with lower energy. To this end the generator of the signal-dependent transformation encoding the signal information on the probe state must be different from the energy. We show that the larger the deviation of the probe state from being the minimum-uncertainty state, the better the resolution.

  5. Minimum variance and variance of outgoing quality limit MDS-1(c1, c2) plans

    Science.gov (United States)

    Raju, C.; Vidya, R.

    2016-06-01

    In this article, the outgoing quality (OQ) and total inspection (TI) of multiple deferred state sampling plans MDS-1(c1,c2) are studied. It is assumed that the inspection is rejection rectification. Procedures for designing MDS-1(c1,c2) sampling plans with minimum variance of OQ and TI are developed. A procedure for obtaining a plan for a designated upper limit for the variance of the OQ (VOQL) is outlined.

  6. Limits of detection and decision. Part 4

    International Nuclear Information System (INIS)

    Voigtman, E.

    2008-01-01

    Probability density functions (PDFs) have been derived for a number of commonly used limit of detection definitions, including several variants of the Relative Standard Deviation of the Background-Background Equivalent Concentration (RSDB-BEC) method, for a simple linear chemical measurement system (CMS) having homoscedastic, Gaussian measurement noise and using ordinary least squares (OLS) processing. All of these detection limit definitions serve as both decision and detection limits, thereby implicitly resulting in 50% rates of Type 2 errors. It has been demonstrated that these are closely related to Currie decision limits, if the coverage factor, k, is properly defined, and that all of the PDFs are scaled reciprocals of noncentral t variates. All of the detection limits have well-defined upper and lower limits, thereby resulting in finite moments and confidence limits, and the problem of estimating the noncentrality parameter has been addressed. As in Parts 1-3, extensive Monte Carlo simulations were performed and all the simulation results were found to be in excellent agreement with the derived theoretical expressions. Specific recommendations for harmonization of detection limit methodology have also been made

  7. Establishment of limits of detection and decision

    International Nuclear Information System (INIS)

    Mende, O.; Michel, R.

    1995-01-01

    The purpose of this project was to develop and test procedures to establish limits of decision and detection for spectrometric nuclear radiation measurements. Beside the determination of the limits of application of DIN 25482 part 2 and 5 - both primarily suitable for high resoluted spectra areas -the statistical model was expanded in such a way that henceforth blanks and influences of sample treatment can also be taken into account; the corresponding procedures to calculate the limits of decision and detection have a high precision. Additional procedures of calculation were developed to take the special characteristics of the analysis of complex spectra areas into account. (orig.) [de

  8. Pushing the limits of NAA. Accuracy, uncertainty and detection limits

    International Nuclear Information System (INIS)

    Greenberg, R.R.

    2008-01-01

    This paper describes some highlights from the author's efforts to improve neutron activation analysis (NAA) detection limits through development and optimization of radiochemical separations, as well as to improve the overall accuracy of NAA measurements by identifying, quantifying and reducing measurement biases and uncertainties. Efforts to demonstrate the metrological basis of NAA, and to establish it as a 'Primary Method of Measurement' will be discussed. (author)

  9. Minimum size limits for yellow perch (Perca flavescens) in western Lake Erie

    Science.gov (United States)

    Hartman, Wilbur L.; Nepszy, Stephen J.; Scholl, Russell L.

    1980-01-01

    During the 1960's yellow perch (Perca flavescens) of Lake Erie supported a commercial fishery that produced an average annual catch of 23 million pounds, as well as a modest sport fishery. Since 1969, the resource has seriously deteriorated. Commercial landings amounted to only 6 million pounds in 1976, and included proportionally more immature perch than in the 1960's. Moreover, no strong year classes were produced between 1965 and 1975. An interagency technical committee was appointed in 1975 by the Lake Erie Committee of the Great Lakes Fishery Commission to develop an interim management strategy that would provide for greater protection of perch in western Lake Erie, where declines have been the most severe. The committee first determined the age structure, growth and mortality rates, maturation schedule, and length-fecundity relationship for the population, and then applied Ricker-type equilibrium yield models to determine the effects of various minimum length limits on yield, production, average stock weight, potential egg deposition, and the Abrosov spawning frequency indicator (average number of spawning opportunities per female). The committee recommended increasing the minimum length limit of 5.0 inches to at least 8.5 inches. Theoretically, this change would increase the average stock weight by 36% and potential egg deposition by 44%, without significantly decreasing yield. Abrosov's spawning frequency indicator would rise from the existing 0.6 to about 1.2.

  10. Minimum Symbol Error Rate Detection in Single-Input Multiple-Output Channels with Markov Noise

    DEFF Research Database (Denmark)

    Christensen, Lars P.B.

    2005-01-01

    Minimum symbol error rate detection in Single-Input Multiple- Output(SIMO) channels with Markov noise is presented. The special case of zero-mean Gauss-Markov noise is examined closer as it only requires knowledge of the second-order moments. In this special case, it is shown that optimal detection...

  11. How low can you go? Assessing minimum concentrations of NSC in carbon limited tree saplings

    Science.gov (United States)

    Hoch, Guenter; Hartmann, Henrik; Schwendener, Andrea

    2016-04-01

    Tissue concentrations of non-structural carbohydrates (NSC) are frequently used to determine the carbon balance of plants. Over the last years, an increasing number of studies have inferred carbon starvation in trees under environmental stress like drought from low tissue NSC concentrations. However, such inferences are limited by the fact that minimum concentrations of NSC required for survival are not known. So far, it was hypothesized that even under lethal carbon starvation, starch and low molecular sugar concentrations cannot be completely depleted and that minimum NSC concentrations at death vary across tissues and species. Here we present results of an experiment that aimed to determine minimum NSC concentrations in different tissues of saplings of two broad-leaved tree species (Acer pseudoplatanus and Quercus petratea) exposed to lethal carbon starvation via continuous darkening. In addition, we investigated recovery rates of NSC concentrations in saplings that had been darkened for different periods of time and were then re-exposed to light. Both species survived continuous darkening for about 12 weeks (confirmed by testing the ability to re-sprout after darkness). In all investigated tissues, starch concentrations declined close to zero within three to six weeks of darkness. Low molecular sugars also decreased strongly within the first weeks of darkness, but seemed to stabilize at low concentrations of 0.5 to 2 % dry matter (depending on tissue and species) almost until death. NSC concentrations recovered surprisingly fast in saplings that were re-exposed to light. After 3 weeks of continuous darkness, tissue NSC concentrations recovered within 6 weeks to levels of unshaded control saplings in all tissues and in both species. To our knowledge, this study represents the first experimental attempt to quantify minimum tissue NSC concentrations at lethal carbon starvation. Most importantly, our results suggest that carbon-starved tree saplings are able to

  12. Energy-minimum sub-threshold self-timed circuits using current-sensing completion detection

    DEFF Research Database (Denmark)

    Akgun, O. C.; Rodrigues, J. N.; Sparsø, Jens

    2011-01-01

    This study addresses the design of self-timed energy-minimum circuits, operating in the sub-VT domain and a generic implementation template using bundled-data circuitry and current sensing completion detection (CSCD). Furthermore, a fully decoupled latch controller was developed, which integrates......V. Spice simulations indicate a gain of 52.58% in throughput because of asynchronous operation. By trading the throughput improvement, energy dissipation is reduced by 16.8% at the energy-minimum supply voltage....

  13. Limits of qualitative detection and quantitative determination

    International Nuclear Information System (INIS)

    Curie, L.A.

    1976-01-01

    The fact that one can find a series of disagreeing and limiting definitions of the detection limit leads to the reinvestigation of the problems of signal detection and signal processing in analytical and nuclear chemistry. Three cut-off levels were fixed: Lsub(C) - the net signal level (sensitivity of the equipment), above which an observed signal can be reliably recognized as 'detected'; Lsub(D) - the 'true' net signal level, from which one can a priori expect a detection; Lsub(Q) - the level at which the measuring accuracy is sufficient for quantitative determination. Exact definition equations as well as a series of working formulae are given for the general analytical case and for the investigation of radioactivity. As it is assumed that the radioactivity of the Poisson distribution is determined, it is dealt with in such a manner that precise limits can be derived for short-lived and long-lived radionuclides with or without disturbance. The fundamentals are made clear by simple examples for spectrophotometry and radioactivity and by a complicated example for activation analysis in which one must choose between alternative nuclear reactions. (orig./LH) [de

  14. Estimation of minimum detectable concentration of chlorine in the blast furnace slag cement concrete

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A., E-mail: aanaqvi@kfupm.edu.s [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Maslehuddin, M. [Center for Engineering Research, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Garwan, M.A.; Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Khateeb-ur-Rehman,; Raashid, M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2011-01-01

    The Prompt Gamma Neutron Activation Analysis technique was used to measure the concentration of chloride in the blast furnace slag (BFS) cement concrete to assess the possibility of reinforcement corrosion. The experimental setup was optimized using Monte Carlo calculations. The BFS concrete specimens containing 0.8-3.5 wt.% chloride were prepared and the concentration of chlorine was evaluated by determining the yield of 6.11, 6.62, 7.41, 7.79 and 8.58 MeV gamma-rays. The Minimum Detectable Concentration (MDC) of chlorine in the BFS cement concrete was estimated. The best value of MDC limit of chlorine in the BFS cement concrete was found to be 0.034 {+-} 0.011 and 0.038 {+-} 0.012 wt.% for 6.11 and 6.62 MeV prompt gamma-rays. Within the statistical uncertainty the lower bound of the measured MDC of chlorine in the BFS cement concrete meets the maximum permissible limit of 0.03 wt.% of chloride set by the American Concrete Institute.

  15. Acoustic observation of living organisms reveals the upper limit of the oxygen minimum zone.

    Directory of Open Access Journals (Sweden)

    Arnaud Bertrand

    Full Text Available BACKGROUND: Oxygen minimum zones (OMZs are expanding in the World Ocean as a result of climate change and direct anthropogenic influence. OMZ expansion greatly affects biogeochemical processes and marine life, especially by constraining the vertical habitat of most marine organisms. Currently, monitoring the variability of the upper limit of the OMZs relies on time intensive sampling protocols, causing poor spatial resolution. METHODOLOGY/PRINCIPAL FINDINGS: Using routine underwater acoustic observations of the vertical distribution of marine organisms, we propose a new method that allows determination of the upper limit of the OMZ with a high precision. Applied in the eastern South-Pacific, this original sampling technique provides high-resolution information on the depth of the upper OMZ allowing documentation of mesoscale and submesoscale features (e.g., eddies and filaments that structure the upper ocean and the marine ecosystems. We also use this information to estimate the habitable volume for the world's most exploited fish, the Peruvian anchovy (Engraulis ringens. CONCLUSIONS/SIGNIFICANCE: This opportunistic method could be implemented on any vessel geared with multi-frequency echosounders to perform comprehensive high-resolution monitoring of the upper limit of the OMZ. Our approach is a novel way of studying the impact of physical processes on marine life and extracting valid information about the pelagic habitat and its spatial structure, a crucial aspect of Ecosystem-based Fisheries Management in the current context of climate change.

  16. A Computable Plug-In Estimator of Minimum Volume Sets for Novelty Detection

    KAUST Repository

    Park, Chiwoo

    2010-10-01

    A minimum volume set of a probability density is a region of minimum size among the regions covering a given probability mass of the density. Effective methods for finding the minimum volume sets are very useful for detecting failures or anomalies in commercial and security applications-a problem known as novelty detection. One theoretical approach of estimating the minimum volume set is to use a density level set where a kernel density estimator is plugged into the optimization problem that yields the appropriate level. Such a plug-in estimator is not of practical use because solving the corresponding minimization problem is usually intractable. A modified plug-in estimator was proposed by Hyndman in 1996 to overcome the computation difficulty of the theoretical approach but is not well studied in the literature. In this paper, we provide theoretical support to this estimator by showing its asymptotic consistency. We also show that this estimator is very competitive to other existing novelty detection methods through an extensive empirical study. ©2010 INFORMS.

  17. A Computable Plug-In Estimator of Minimum Volume Sets for Novelty Detection

    KAUST Repository

    Park, Chiwoo; Huang, Jianhua Z.; Ding, Yu

    2010-01-01

    A minimum volume set of a probability density is a region of minimum size among the regions covering a given probability mass of the density. Effective methods for finding the minimum volume sets are very useful for detecting failures or anomalies in commercial and security applications-a problem known as novelty detection. One theoretical approach of estimating the minimum volume set is to use a density level set where a kernel density estimator is plugged into the optimization problem that yields the appropriate level. Such a plug-in estimator is not of practical use because solving the corresponding minimization problem is usually intractable. A modified plug-in estimator was proposed by Hyndman in 1996 to overcome the computation difficulty of the theoretical approach but is not well studied in the literature. In this paper, we provide theoretical support to this estimator by showing its asymptotic consistency. We also show that this estimator is very competitive to other existing novelty detection methods through an extensive empirical study. ©2010 INFORMS.

  18. Improvement in minimum detectable activity for low energy gamma by optimization in counting geometry

    Directory of Open Access Journals (Sweden)

    Anil Gupta

    2017-01-01

    Full Text Available Gamma spectrometry for environmental samples of low specific activities demands low minimum detection levels of measurement. An attempt has been made to lower the gamma detection level of measurement by optimizing the sample geometry, without compromising on the sample size. Gamma energy of 50–200 keV range was chosen for the study, since low energy gamma photons suffer the most self-attenuation within matrix. The simulation study was carried out using MCNP based software “EffCalcMC” for silica matrix and cylindrical geometries. A volume of 250 ml sample geometry of 9 cm diameter is optimized as the best suitable geometry for use, against the in-practice 7 cm diameter geometry of same volume. An increase in efficiency of 10%–23% was observed for the 50–200 keV gamma energy range and a corresponding lower minimum detectable activity of 9%–20% could be achieved for the same.

  19. How long is enough to detect terrestrial animals? Estimating the minimum trapping effort on camera traps

    Directory of Open Access Journals (Sweden)

    Xingfeng Si

    2014-05-01

    Full Text Available Camera traps is an important wildlife inventory tool for estimating species diversity at a site. Knowing what minimum trapping effort is needed to detect target species is also important to designing efficient studies, considering both the number of camera locations, and survey length. Here, we take advantage of a two-year camera trapping dataset from a small (24-ha study plot in Gutianshan National Nature Reserve, eastern China to estimate the minimum trapping effort actually needed to sample the wildlife community. We also evaluated the relative value of adding new camera sites or running cameras for a longer period at one site. The full dataset includes 1727 independent photographs captured during 13,824 camera days, documenting 10 resident terrestrial species of birds and mammals. Our rarefaction analysis shows that a minimum of 931 camera days would be needed to detect the resident species sufficiently in the plot, and c. 8700 camera days to detect all 10 resident species. In terms of detecting a diversity of species, the optimal sampling period for one camera site was c. 40, or long enough to record about 20 independent photographs. Our analysis of evaluating the increasing number of additional camera sites shows that rotating cameras to new sites would be more efficient for measuring species richness than leaving cameras at fewer sites for a longer period.

  20. Minimum detection efficiency for the loophole-free confirmation of quantum contextuality

    International Nuclear Information System (INIS)

    Xiang Yang; Hong Fang-Yu

    2013-01-01

    Klyachko—Can—Binicioğlu—Shumovsky (KCBS) inequality is a Bell-like inequality, the violation of which can be used to confirm the existence of quantum contextuality. However, the imperfection of detection efficiency may cause the so-called loophole in actual KCBS's experiments. We derive an alternative KCBS inequality to deal with the loophole in actual KCBS's experiments. We prove that if the experimental data violate this KCBS inequality, the loophole-free violation of the original KCBS inequality will occur. We show that the minimum detection efficiency needed for a loophole-free violation of the KCBS inequality is about 0.9738

  1. 40 CFR Table 13 to Subpart Xxxx of... - Minimum Data for Continuous Compliance With the Emission Limitations for Puncture Sealant...

    Science.gov (United States)

    2010-07-01

    ... XXXX of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... Standards for Hazardous Air Pollutants: Rubber Tire Manufacturing Pt. 63, Subpt. XXXX, Table 13 Table 13 to Subpart XXXX of Part 63—Minimum Data for Continuous Compliance With the Emission Limitations for Puncture...

  2. Feedback damping of a microcantilever at room temperature to the minimum vibration amplitude limited by the noise level.

    Science.gov (United States)

    Kawamura, Y; Kanegae, R

    2016-06-17

    Cooling the vibration amplitude of a microcantilever as low as possible is important to improve the sensitivity and resolutions of various types of scanning type microscopes and sensors making use of it. When the vibration amplitude is controlled to be smaller using a feed back control system, it is known that the obtainable minimum amplitude of the vibration is limited by the floor noise level of the detection system. In this study, we demonstrated that the amplitude of the thermal vibration of a microcantilever was suppressed to be about 0.15 pmHz(-1/2), which is the same value with the floor noise level, without the assistance of external cryogenic cooling. We think that one of the reason why we could reach the smaller amplitude at room temperature is due to stiffer spring constant of the lever, which leads to higher natural frequency and consequently lower floor noise level. The other reason is considered to be due to the increase in the laser power for the diagnostics, which lead to the decrease in the signal to noise ratio determined by the optical shot noise.

  3. N2 production rates limited by nitrite availability in the Bay of Bengal oxygen minimum zone

    DEFF Research Database (Denmark)

    Bristow, Laura A.; Callbeck, C. M.; Larsen, M

    2017-01-01

    with isotopically labelled nitrogen compounds and analyse geochemical signatures of these processes in the water column. We find that the Bay of Bengal supports denitrifier and anammox microbial populations, mediating low, but significant N loss. Yet, unlike other oxygen minimum zones, our measurements using...

  4. N2 production rates limited by nitrite availability in the Bay of Bengal oxygen minimum zone

    Digital Repository Service at National Institute of Oceanography (India)

    Bristow, L.A; Callbeck, C.M.; Larsen, M.; Altabet, M.A; Dekaezemacker, J.; Forth, M.; Gauns, M.; Glud, R.N.; Kuypers, M.M.M.; Lavik, G.; Milucka, J.; Naqvi, S.W.A; Pratihary, A; Revsbech, N.P.; Thamdrup, B.; Treusch, A; Canfield, D.E.

    A third or more of the fixed nitrogen lost from the oceans as N2 is removed by anaerobic microbial processes in open ocean oxygen minimum zones. These zones have expanded over the past decades, and further anthropogenically induced...

  5. 49 CFR 387.303 - Security for the protection of the public: Minimum limits.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Security for the protection of the public: Minimum... Insurance for Motor Carriers and Property Brokers § 387.303 Security for the protection of the public... convenience of the user, the revised text is set forth as follows: § 387.303 Security for the protection of...

  6. Minimum detectable activities for natural radionuclides for IRIS-XP airborne gamma-spectrometer

    International Nuclear Information System (INIS)

    Ohera, Marcel; Sladek, Petr

    2009-01-01

    To subtract the 90 Sr background in the helicopter (the 90 Sr source is used as a freezing deposit indicator in Mi-17 helicopters), a spectrum at the altitude of more than 500 metre altitude above the ground for 10 minutes was acquired. The spectra at 50, 100 and 150 m altitude were corrected for the aircraft and the cosmics, stripping and height attenuation in K, U and Th peak windows. For IRIS-XP, better results have been obtained than presented so far. The new calculated minimum detectable activities (MDAs) are 114 Bq/kg for 40 K, 16 Bq/kg for 238 U and 8 Bq/kg for 232 Th at 95% confidence interval for 1 second spectra at 100 m altitude. This work deals with counting statistics and the estimate of the MDAs for natural radionuclides for the IRIS-XP airborne gamma-ray spectrometer (4 x 4 litre NaI(Tl)) produced by PICO Envirotec, Inc. in Toronto, Canada. The detection sensitivities (MDA) for 4 x 4 NaI(Tl) crystals at the altitude of 90 m presented by Pico Envirotec, Inc. are too high compared with the detection sensitivities presented by other airborne gamma-ray spectrometer producers. This was the reason why to calculate and verify the MDA for IRIS-XP. Firstly, the minimum detectable activities for IRIS-XP for 4 x 4 litre NaI(Tl) crystals were determined based on the data acquired on the calibration pads at the Holland Landing Airport in Toronto, Canada to test the method of calculation used. This method on calibration pads provides all available window sensitivities, stripping factors and counts in the natural radionuclide windows to verify the computing method. Secondly, the MDAs under the real flight conditions were also estimated for the IRIS-XP (4 x 4 litre NaI(Tl) crystals) which was delivered to the Czech Armed Forces. The MDAs were calculated based on the data acquired during the tests at the Military Training Area in Vyskov, Czech Republic. The data was collected at three different altitudes (50 m, 100 m and 150 m) when the Mi-17 helicopter with IRIS

  7. Discuss the technology for decrease the detection limit of NaI(Tl) gamma spectrometer

    International Nuclear Information System (INIS)

    Guo Xiaobin; Qu Guopu; Liu Zhiying; Wang Hongyan; Wang Lieming

    2011-01-01

    The radioelement species is complex and quantity is few after nuclear explosion, thus it is hard to tell the difference when using the Nal (TI) Gamma spectrometer detection due to several kinds of the peak of nuclide overlapped in the scattering region. So there is a high demand for spectrometer stability, energy resolution, solution spectrum and minimum detective activity. The paper analysed the influenced factors to Nal (TI) Gamma spectrometer and the measures of detection limit decrease by experiments and MCNP simulation, which proposed the methods to reduce background through shielding in order to improve minimum detective activity. The experiment shows that choosing reasonable shielding can reduce the background effectively and improve the spectrometer low level radioactive detect ability. (authors)

  8. PROBABILITY CALIBRATION BY THE MINIMUM AND MAXIMUM PROBABILITY SCORES IN ONE-CLASS BAYES LEARNING FOR ANOMALY DETECTION

    Data.gov (United States)

    National Aeronautics and Space Administration — PROBABILITY CALIBRATION BY THE MINIMUM AND MAXIMUM PROBABILITY SCORES IN ONE-CLASS BAYES LEARNING FOR ANOMALY DETECTION GUICHONG LI, NATHALIE JAPKOWICZ, IAN HOFFMAN,...

  9. Cellulose accessibility limits the effectiveness of minimum cellulase loading on the efficient hydrolysis of pretreated lignocellulosic substrates

    Directory of Open Access Journals (Sweden)

    Saddler Jack N

    2011-02-01

    Full Text Available Abstract A range of lignocellulosic feedstocks (including agricultural, softwood and hardwood substrates were pretreated with either sulfur dioxide-catalyzed steam or an ethanol organosolv procedure to try to establish a reliable assessment of the factors governing the minimum protein loading that could be used to achieve efficient hydrolysis. A statistical design approach was first used to define what might constitute the minimum protein loading (cellulases and β-glucosidase that could be used to achieve efficient saccharification (defined as at least 70% glucan conversion of the pretreated substrates after 72 hours of hydrolysis. The likely substrate factors that limit cellulose availability/accessibility were assessed, and then compared with the optimized minimum amounts of protein used to obtain effective hydrolysis. The optimized minimum protein loadings to achieve efficient hydrolysis of seven pretreated substrates ranged between 18 and 63 mg protein per gram of glucan. Within the similarly pretreated group of lignocellulosic feedstocks, the agricultural residues (corn stover and corn fiber required significantly lower protein loadings to achieve efficient hydrolysis than did the pretreated woody biomass (poplar, douglas fir and lodgepole pine. Regardless of the substantial differences in the source, structure and chemical composition of the feedstocks, and the difference in the pretreatment technology used, the protein loading required to achieve efficient hydrolysis of lignocellulosic substrates was strongly dependent on the accessibility of the cellulosic component of each of the substrates. We found that cellulose-rich substrates with highly accessible cellulose, as assessed by the Simons' stain method, required a lower protein loading per gram of glucan to obtain efficient hydrolysis compared with substrates containing less accessible cellulose. These results suggest that the rate-limiting step during hydrolysis is not the catalytic

  10. Reliability and Minimum Detectable Change of Temporal-Spatial, Kinematic, and Dynamic Stability Measures during Perturbed Gait.

    Directory of Open Access Journals (Sweden)

    Christopher A Rábago

    Full Text Available Temporal-spatial, kinematic variability, and dynamic stability measures collected during perturbation-based assessment paradigms are often used to identify dysfunction associated with gait instability. However, it remains unclear which measures are most reliable for detecting and tracking responses to perturbations. This study systematically determined the between-session reliability and minimum detectable change values of temporal-spatial, kinematic variability, and dynamic stability measures during three types of perturbed gait. Twenty young healthy adults completed two identical testing sessions two weeks apart, comprised of an unperturbed and three perturbed (cognitive, physical, and visual walking conditions in a virtual reality environment. Within each session, perturbation responses were compared to unperturbed walking using paired t-tests. Between-session reliability and minimum detectable change values were also calculated for each measure and condition. All temporal-spatial, kinematic variability and dynamic stability measures demonstrated fair to excellent between-session reliability. Minimal detectable change values, normalized to mean values ranged from 1-50%. Step width mean and variability measures demonstrated the greatest response to perturbations with excellent between-session reliability and low minimum detectable change values. Orbital stability measures demonstrated specificity to perturbation direction and sensitivity with excellent between-session reliability and low minimum detectable change values. We observed substantially greater between-session reliability and lower minimum detectable change values for local stability measures than previously described which may be the result of averaging across trials within a session and using velocity versus acceleration data for reconstruction of state spaces. Across all perturbation types, temporal-spatial, orbital and local measures were the most reliable measures with the

  11. Minimum current principle and variational method in theory of space charge limited flow

    Energy Technology Data Exchange (ETDEWEB)

    Rokhlenko, A. [Department of Mathematics, Rutgers University, Piscataway, New Jersey 08854-8019 (United States)

    2015-10-21

    In spirit of the principle of least action, which means that when a perturbation is applied to a physical system, its reaction is such that it modifies its state to “agree” with the perturbation by “minimal” change of its initial state. In particular, the electron field emission should produce the minimum current consistent with boundary conditions. It can be found theoretically by solving corresponding equations using different techniques. We apply here the variational method for the current calculation, which can be quite effective even when involving a short set of trial functions. The approach to a better result can be monitored by the total current that should decrease when we on the right track. Here, we present only an illustration for simple geometries of devices with the electron flow. The development of these methods can be useful when the emitter and/or anode shapes make difficult the use of standard approaches. Though direct numerical calculations including particle-in-cell technique are very effective, but theoretical calculations can provide an important insight for understanding general features of flow formation and even sometimes be realized by simpler routines.

  12. Correction to the count-rate detection limit and sample/blank time-allocation methods

    International Nuclear Information System (INIS)

    Alvarez, Joseph L.

    2013-01-01

    A common form of count-rate detection limits contains a propagation of uncertainty error. This error originated in methods to minimize uncertainty in the subtraction of the blank counts from the gross sample counts by allocation of blank and sample counting times. Correct uncertainty propagation showed that the time allocation equations have no solution. This publication presents the correct form of count-rate detection limits. -- Highlights: •The paper demonstrated a proper method of propagating uncertainty of count rate differences. •The standard count-rate detection limits were in error. •Count-time allocation methods for minimum uncertainty were in error. •The paper presented the correct form of the count-rate detection limit. •The paper discussed the confusion between count-rate uncertainty and count uncertainty

  13. Optical Coherence Tomography Minimum Intensity as an Objective Measure for the Detection of Hydroxychloroquine Toxicity.

    Science.gov (United States)

    Allahdina, Ali M; Stetson, Paul F; Vitale, Susan; Wong, Wai T; Chew, Emily Y; Ferris, Fredrick L; Sieving, Paul A; Cukras, Catherine

    2018-04-01

    As optical coherence tomography (OCT) minimum intensity (MI) analysis provides a quantitative assessment of changes in the outer nuclear layer (ONL), we evaluated the ability of OCT-MI analysis to detect hydroxychloroquine toxicity. Fifty-seven predominantly female participants (91.2% female; mean age, 55.7 ± 10.4 years; mean time on hydroxychloroquine, 15.0 ± 7.5 years) were enrolled in a case-control study and categorized into affected (i.e., with toxicity, n = 19) and unaffected (n = 38) groups using objective multifocal electroretinographic (mfERG) criteria. Spectral-domain OCT scans of the macula were analyzed and OCT-MI values quantitated for each subfield of the Early Treatment Diabetic Retinopathy Study (ETDRS) grid. A two-sample U-test and a cross-validation approach were used to assess the sensitivity and specificity of toxicity detection according to OCT-MI criteria. The medians of the OCT-MI values in all nine of the ETDRS subfields were significantly elevated in the affected group relative to the unaffected group (P < 0.005 for all comparisons), with the largest difference found for the inner inferior subfield (P < 0.0001). The receiver operating characteristic analysis of median MI values of the inner inferior subfields showed high sensitivity and high specificity in the detection of toxicity with area under the curve = 0.99. Retinal changes secondary to hydroxychloroquine toxicity result in increased OCT reflectivity in the ONL that can be detected and quantitated using OCT-MI analysis. Analysis of OCT-MI values demonstrates high sensitivity and specificity for detecting the presence of hydroxychloroquine toxicity in this cohort and may contribute additionally to current screening practices.

  14. Detection limits for radioanalytical counting techniques

    International Nuclear Information System (INIS)

    Hartwell, J.K.

    1975-06-01

    In low-level radioanalysis it is usually necessary to test the sample net counts against some ''Critical Level'' in order to determine if a given result indicates detection. This is an interpretive review of the work by Nicholson (1963), Currie (1968) and Gilbert (1974). Nicholson's evaluation of three different computational formulas for estimation of the ''Critical Level'' is discussed. The details of Nicholson's evaluation are presented along with a basic discussion of the testing procedures used. Recommendations are presented for calculation of confidence intervals, for reporting of analytical results, and for extension of the derived formula to more complex cases such as multiple background counts, multiple use of a single background count, and gamma spectrometric analysis

  15. Detection Limits Of The 125I Air Sampler ''RIS125''

    International Nuclear Information System (INIS)

    Belaish, I.; Levinson, S.; German, U.; Kravchik, T.

    1999-01-01

    A system for 125 I monitoring in air (RIS-125) was designed and manufactured at NRCN. The main features of the system are described elsewhere. The system can monitor 125 I air contamination in gaseous and aerosol forms. An air monitoring system should have a fast response and the lowest available Minimum Detectable Activity (MDA). The present work presents the characteristic MDA values of the system

  16. On the relationship of minimum detectable contrast to dose and lesion size in abdominal CT

    International Nuclear Information System (INIS)

    Zhou, Yifang; Scott, Alexander II; Allahverdian, Janet; Lee, Christina; Kightlinger, Blake; Azizyan, Avetis; Miller, Joseph

    2015-01-01

    CT dose optimization is typically guided by pixel noise or contrast-to-noise ratio that does not delineate low contrast details adequately. We utilized the statistically defined low contrast detectability to study its relationship to dose and lesion size in abdominal CT. A realistically shaped medium sized abdomen phantom was customized to contain a cylindrical void of 4 cm diameter. The void was filled with a low contrast (1% and 2%) insert containing six groups of cylindrical targets ranging from 1.2 mm to 7 mm in size. Helical CT scans were performed using a Siemens 64-slice mCT and a GE Discovery 750 HD at various doses. After the subtractions between adjacent slices, the uniform sections of the filtered backprojection reconstructed images were partitioned to matrices of square elements matching the sizes of the targets. It was verified that the mean values from all the elements in each matrix follow a Gaussian distribution. The minimum detectable contrast (MDC), quantified by the mean signal to background difference equal to the distribution’s standard deviation multiplied by 3.29, corresponding to 95% confidence level, was found to be related to the phantom specific dose and the element size by a power law (R 2   >  0.990). Independent readings on the 5 mm and 7 mm targets were compared to the measured contrast to the MDC ratios. The results showed that 93% of the cases were detectable when the measured contrast exceeds the MDC. The correlation of the MDC to the pixel noise and target size was also identified and the relationship was found to be the same for the scanners in the study. To quantify the impact of iterative reconstructions to the low contrast detectability, the noise structure was studied in a similar manner at different doses and with different ASIR blending fractions. The relationship of the dose to the blending fraction and low contrast detectability is presented. (paper)

  17. On the relationship of minimum detectable contrast to dose and lesion size in abdominal CT

    Science.gov (United States)

    Zhou, Yifang; Scott, Alexander, II; Allahverdian, Janet; Lee, Christina; Kightlinger, Blake; Azizyan, Avetis; Miller, Joseph

    2015-10-01

    CT dose optimization is typically guided by pixel noise or contrast-to-noise ratio that does not delineate low contrast details adequately. We utilized the statistically defined low contrast detectability to study its relationship to dose and lesion size in abdominal CT. A realistically shaped medium sized abdomen phantom was customized to contain a cylindrical void of 4 cm diameter. The void was filled with a low contrast (1% and 2%) insert containing six groups of cylindrical targets ranging from 1.2 mm to 7 mm in size. Helical CT scans were performed using a Siemens 64-slice mCT and a GE Discovery 750 HD at various doses. After the subtractions between adjacent slices, the uniform sections of the filtered backprojection reconstructed images were partitioned to matrices of square elements matching the sizes of the targets. It was verified that the mean values from all the elements in each matrix follow a Gaussian distribution. The minimum detectable contrast (MDC), quantified by the mean signal to background difference equal to the distribution’s standard deviation multiplied by 3.29, corresponding to 95% confidence level, was found to be related to the phantom specific dose and the element size by a power law (R^2  >  0.990). Independent readings on the 5 mm and 7 mm targets were compared to the measured contrast to the MDC ratios. The results showed that 93% of the cases were detectable when the measured contrast exceeds the MDC. The correlation of the MDC to the pixel noise and target size was also identified and the relationship was found to be the same for the scanners in the study. To quantify the impact of iterative reconstructions to the low contrast detectability, the noise structure was studied in a similar manner at different doses and with different ASIR blending fractions. The relationship of the dose to the blending fraction and low contrast detectability is presented.

  18. Quality control of radiation counting systems and measurement of minimum detectable activity

    International Nuclear Information System (INIS)

    Song, Byoung Chul; Han, Sung Sim; Kim, Young Bok; Jee, Kwang Yong; Sohn, Se Chul

    2004-01-01

    Various radiation counters have been using to determine radioactivity of radwastes for disposal. A radiation counting system was set up using a radiation detector chosen in this study and its stability was investigated through the periodic determination of background and counting efficiencies in accordance with a quality control program to increase the confidence level. The average background level for the γ-spectrometer was 1.59 cps and the average counting level for the standard sample was 45248 dps within 20 confidence levels. The average alpha background level for the low background α/β counting system was 0.31 cpm and the efficiency for alpha counting was 34.38 %. The average beta background level for the α/β counting system was 1.30 cpm and the efficiency for beta counting was 46.5%. The background level in the region of 3H and 14C for the liquid scintillation counting system was 2.52 and 3.31 cpm and the efficiency for alpha counting was 58.5 and 95.6%, respectively. The minimum detectable activity for the γ-spectrometer was found to be 3.2 Bq/mL and 3.8 Bq/mL for the liquid scintillation counter, and 20.5 and 23.0 Bq/mL, respectively for the α and β counting system

  19. On the lower of limit detection of radiometric systems

    International Nuclear Information System (INIS)

    Kamburov, H.; Boneva, S.

    1983-01-01

    The existing definitions of the quantity Asub(min), the lower detection limit, introduced as a characteristic of the sensitivity of radiometric systems are reviewed. A convenient way is found for comparing the different definitions by showing that each definition is connected with a specific value of the probability a of Type I error. The detection limits are calculated for a normal and Poisson distributions of the measured quantities. A criterion is proposed for the applicability of the normal distiribution to the problem of determining the lower detection limit

  20. Detection limit calculations for different total reflection techniques

    International Nuclear Information System (INIS)

    Sanchez, H.J.

    2000-01-01

    In this work, theoretical calculations of detection limits for different total-reflection techniques are presented.. Calculations include grazing incidence (TXRF) and gracing exit (GEXRF) conditions. These calculations are compared with detection limits obtained for conventional x-ray fluorescence (XRF). In order to compute detection limits the Shiraiwa and Fujino's model to calculate x-ray fluorescence intensities was used. This model made certain assumptions and approximations to achieve the calculations, specially in the case of the geometrical conditions of the sample, and the incident and takeoff beams. Nevertheless the calculated data of detection limits for conventional XRF and total-reflection XRF show a good agreement with previous results. The model proposed here allows to analyze the different sources of background and the influence of the excitation geometry, which contribute to the understanding of the physical processes involved in the XRF analysis by total reflection. Finally, a comparison between detection limits in total-reflection analysis at grazing incidence and at grazing exit is carried out. Here a good agreement with the theoretical predictions of the reversibility principle is found, showing that detection limits are similar for both techniques. (author)

  1. Importance of the lower limit of detection in radiological safety

    International Nuclear Information System (INIS)

    Rafael Terol T.; Hermenegildo Maldonado M.

    1991-01-01

    The concept of the Lower Limit of Detection (LLD) it contributes in the solution of some problems related with the radiological safety, such as the realization of the tests of flight of the sealed radioactive sources; the determination of radioisotopes in environmental samples; the estimate of present radionuclides in polluted foods; in general, the detection of small quantities of radioactive materials present in materials of use or consumption by part of the man in his daily life; as the one Lower Limit of Detection is related with topics of statistics, in this work a small review of them is made, it was superficially discussed the mensuration problems related with the establishment of the Lower Limit of Detection

  2. Calculation of the detection limit in radiation measurements with systematic uncertainties

    International Nuclear Information System (INIS)

    Kirkpatrick, J.M.; Russ, W.; Venkataraman, R.; Young, B.M.

    2015-01-01

    The detection limit (L D ) or Minimum Detectable Activity (MDA) is an a priori evaluation of assay sensitivity intended to quantify the suitability of an instrument or measurement arrangement for the needs of a given application. Traditional approaches as pioneered by Currie rely on Gaussian approximations to yield simple, closed-form solutions, and neglect the effects of systematic uncertainties in the instrument calibration. These approximations are applicable over a wide range of applications, but are of limited use in low-count applications, when high confidence values are required, or when systematic uncertainties are significant. One proposed modification to the Currie formulation attempts account for systematic uncertainties within a Gaussian framework. We have previously shown that this approach results in an approximation formula that works best only for small values of the relative systematic uncertainty, for which the modification of Currie's method is the least necessary, and that it significantly overestimates the detection limit or gives infinite or otherwise non-physical results for larger systematic uncertainties where such a correction would be the most useful. We have developed an alternative approach for calculating detection limits based on realistic statistical modeling of the counting distributions which accurately represents statistical and systematic uncertainties. Instead of a closed form solution, numerical and iterative methods are used to evaluate the result. Accurate detection limits can be obtained by this method for the general case

  3. The limit of detection for explosives in spectroscopic differential reflectometry

    Science.gov (United States)

    Dubroca, Thierry; Vishwanathan, Karthik; Hummel, Rolf E.

    2011-05-01

    In the wake of recent terrorist attacks, such as the 2008 Mumbai hotel explosion or the December 25th 2009 "underwear bomber", our group has developed a technique (US patent #7368292) to apply differential reflection spectroscopy to detect traces of explosives. Briefly, light (200-500 nm) is shone on a surface such as a piece of luggage at an airport. Upon reflection, the light is collected with a spectrometer combined with a CCD camera. A computer processes the data and produces in turn a differential reflection spectrum involving two adjacent areas of the surface. This differential technique is highly sensitive and provides spectroscopic data of explosives. As an example, 2,4,6, trinitrotoluene (TNT) displays strong and distinct features in differential reflectograms near 420 nm. Similar, but distinctly different features are observed for other explosives. One of the most important criteria for explosive detection techniques is the limit of detection. This limit is defined as the amount of explosive material necessary to produce a signal to noise ratio of three. We present here, a method to evaluate the limit of detection of our technique. Finally, we present our sample preparation method and experimental set-up specifically developed to measure the limit of detection for our technology. This results in a limit ranging from 100 nano-grams to 50 micro-grams depending on the method and the set-up parameters used, such as the detector-sample distance.

  4. Confirmation of identity and detection limit in neutron activation analysis

    International Nuclear Information System (INIS)

    Yustina Tri Handayani; Slamet Wiyuniati; Tulisna

    2010-01-01

    Neutron Activation Analysis (NAA) based on neutron capture by nuclides. Of the various possibilities of radionuclides that occur, radionuclides and gamma radiation which provides the identity of the element were analyzed and the best sensitivity should be determined. Confirmation for elements in sediment samples was done theoretically and experimentally. The result of confirmation shows that Al, V, Cr K, Na, Ca and Zn were analyzed based on radionuclides of Al-28, V-52, Cr-51 , K-42, Na-24, Ca-48, Zn-65. Elements of Mg, Mn, Fe, Co were analyzed based on radionuclides of Mg-27, Mn-56, Fe-59, Co-60 through peak which the highest value of combined probability of radiation emission and efficiency. Cu can be analyzed through Cu-64 or Cu-66, but the second is more sensitive. Detection limit is determined at a certain measurement conditions carried out by a laboratory. Detection limit in the NAA is determined based on the Compton continue area by Curie method. The detection limit of Al, V, Ca, Mg, Mn, As, K, Na, Mg, Ce, Co, Cr, Fe, La, Sc, and Zn in sediment samples are 240, 27, 4750, 2600, 21, 3.3 , 75, 1.4, 1.8, 0.5, 2.7, 29, 1, 0.05, and 37 ppm. Analysis of Cu in sediments which concentrations of 98.6 ppm, Cu-66 is not detected. Tests using pure standard solutions of Cu obtained detection limit of 0.12 µg, or 7.9 ppm in samples of 15 mg. In general, the detection limit obtained was higher than the detection limit of the reference, it was caused by the differences in the sample matrix and analytical conditions. (author)

  5. Limits of Tumor Detectability in Nuclear Medicine and PET

    Directory of Open Access Journals (Sweden)

    Yusuf Emre Erdi

    2012-04-01

    Full Text Available Objective: Nuclear medicine is becoming increasingly important in the early detection of malignancy. The advantage of nuclear medicine over other imaging modalities is the high sensitivity of the gamma camera. Nuclear medicine counting equipment has the capability of detecting levels of radioactivity which exceed background levels by as little as 2.4 to 1. This translates to only a few hundred counts per minute on a regular gamma camera or as few as 3 counts per minute when using coincidence detection on a positron emission tomography (PET camera. Material and Methods: We have experimentally measured the limits of detectability using a set of hollow spheres in a Jaszczak phantom at various tumor-to-background ratios. Imaging modalities for this work were (1 planar, (2 SPECT, (3 PET, and (4 planar camera with coincidence detection capability (MCD. Results: When there is no background (infinite contrast activity present, the detectability of tumors is similar for PET and planar imaging. With the presence of the background activity , PET can detect objects in an order of magnitude smaller in size than that can be seen by conventional planar imaging especially in the typical clinical low (3:1 T/B ratios. The detection capability of the MCD camera lies between a conventional nuclear medicine (planar / SPECT scans and the detection capability of a dedicated PET scanner Conclusion: Among nuclear medicine’s armamentarium, PET is the closest modality to CT or MR imaging in terms of limits of detection. Modern clinical PET scanners have a resolution limit of 4 mm, corresponding to the detection of tumors with a volume of 0.2 ml (7 mm diameter in 5:1 T/B ratio. It is also possible to obtain better resolution limits with dedicated brain and animal scanners. The future holds promise in development of new detector materials, improved camera design, and new reconstruction algorithms which will improve sensitivity, resolution, contrast, and thereby further

  6. 40 CFR Table 11 to Subpart Xxxx of... - Minimum Data for Continuous Compliance With the Emission Limits for Tire Cord Production Affected...

    Science.gov (United States)

    2010-07-01

    ... With the Emission Limits for Tire Cord Production Affected Sources 11 Table 11 to Subpart XXXX of Part... for Hazardous Air Pollutants: Rubber Tire Manufacturing Pt. 63, Subpt. XXXX, Table 11 Table 11 to Subpart XXXX of Part 63—Minimum Data for Continuous Compliance With the Emission Limits for Tire Cord...

  7. Critical review for the determination of the minimum detectable activity (MDA) of alpha-emitter radionuclides in environmental samples

    International Nuclear Information System (INIS)

    Gasco, C.; Anton, M.P.

    1996-12-01

    Different criteria for the calculation of the Minimum Detectable Activity (MDA) of an alpha emitter in environmental levels are reviewed in this report. Practical examples of its application to previously analyzed samples are shown. The authors propose a criteria based on prior calculations that applies to the radiochemical activities performed in the laboratory. The calculation procedure has been discussed with scientist from other laboratories in order to establish a general criteria to calculate the MDA

  8. Assessment of Hydrogen Sulfide Minimum Detection Limits of an Open Path Tunable Diode Laser

    Science.gov (United States)

    During June 2007, U.S. EPA conducted a feasibility study to determine whether the EPA OTM 10 measurement approach, also known as radial plume mapping (RPM), was feasible. A Boreal open-path tunable diode laser (OP-TDL) to collect path-integrated hydrogen sulfide measurements alon...

  9. No evidence for an item limit in change detection.

    Directory of Open Access Journals (Sweden)

    Shaiyan Keshvari

    Full Text Available Change detection is a classic paradigm that has been used for decades to argue that working memory can hold no more than a fixed number of items ("item-limit models". Recent findings force us to consider the alternative view that working memory is limited by the precision in stimulus encoding, with mean precision decreasing with increasing set size ("continuous-resource models". Most previous studies that used the change detection paradigm have ignored effects of limited encoding precision by using highly discriminable stimuli and only large changes. We conducted two change detection experiments (orientation and color in which change magnitudes were drawn from a wide range, including small changes. In a rigorous comparison of five models, we found no evidence of an item limit. Instead, human change detection performance was best explained by a continuous-resource model in which encoding precision is variable across items and trials even at a given set size. This model accounts for comparison errors in a principled, probabilistic manner. Our findings sharply challenge the theoretical basis for most neural studies of working memory capacity.

  10. Improvement of detection limits of PIXE by substrate signal reduction

    International Nuclear Information System (INIS)

    Beaulieu, S.; Nejedly, Z.; Campbell, J.L.; Edwards, G.C.; Dias, G.M.

    2002-01-01

    Limits of detection (LODs) for aerosol samples collected using PIXE International cascade impactors, were improved approximately 50% after reducing the cross-sectional area of the analytical beam based on results obtained from microscope photographs of aerosol deposits. Improvements in LODs were most noticeable for selected elements collected on the smaller stages of the impactor (stages 1-3)

  11. Realistic limitations of detecting planets around young active stars

    Directory of Open Access Journals (Sweden)

    Pinfield D.

    2013-04-01

    Full Text Available Current planet hunting methods using the radial velocity method are limited to observing middle-aged main-sequence stars where the signatures of stellar activity are much less than on young stars that have just arrived on the main-sequence. In this work we apply our knowledge from the surface imaging of these young stars to place realistic limitations on the possibility of detecting orbiting planets. In general we find that the magnitude of the stellar jitter is directly proportional to the stellar vsini. For G and K dwarfs, we find that it is possible, for models with high stellar activity and low stellar vsini, to be able to detect a 1 MJupiter mass planet within 50 epochs of observations and for the M dwarfs it is possible to detect a habitable zone Earth-like planet in 10s of observational epochs.

  12. Stochastic fluctuations and the detectability limit of network communities.

    Science.gov (United States)

    Floretta, Lucio; Liechti, Jonas; Flammini, Alessandro; De Los Rios, Paolo

    2013-12-01

    We have analyzed the detectability limits of network communities in the framework of the popular Girvan and Newman benchmark. By carefully taking into account the inevitable stochastic fluctuations that affect the construction of each and every instance of the benchmark, we come to the conclusion that the native, putative partition of the network is completely lost even before the in-degree/out-degree ratio becomes equal to that of a structureless Erdös-Rényi network. We develop a simple iterative scheme, analytically well described by an infinite branching process, to provide an estimate of the true detectability limit. Using various algorithms based on modularity optimization, we show that all of them behave (semiquantitatively) in the same way, with the same functional form of the detectability threshold as a function of the network parameters. Because the same behavior has also been found by further modularity-optimization methods and for methods based on different heuristics implementations, we conclude that indeed a correct definition of the detectability limit must take into account the stochastic fluctuations of the network construction.

  13. Determining the lower limit of detection for personnel dosimetry systems

    International Nuclear Information System (INIS)

    Roberson, P.L.; Carlson, R.D.

    1992-01-01

    A simple method for determining the lower limit of detection (LLD) for personnel dosimetry systems is described. The method relies on the definition of a critical level and a detection level. The critical level is the signal level above which a result has a small probability of being due to a fluctuation of the background. All results below the critical level should not be reported as an indication of a positive result. The detection level is the net signal level (i.e., dose received) above which there is a high confidence that a true reading will be detected and reported as a qualitatively positive result. The detection level may be identified as the LLD. A simple formula is derived to allow the calculation of the LLD under various conditions. This type of formula is being used by the Department of Energy Laboratory Accreditation Program (DOELAP) for personnel dosimetry. Participants in either the National Voluntary Laboratory Accreditation Program (NVLAP) for personnel dosimetry or DOELAP can use performance test results along with a measurement of background levels to estimate the LLDs for their dosimetry system. As long as they maintain their dosimetry system such that the LLDs are less than half the lower limit of the NVLAP or DOELAP test exposure ranges, dosimetry laboratories can avoid testing failures due to poor performance at very low exposures

  14. Limiter discriminator detection of M-ary FSK signals

    Science.gov (United States)

    Fonseka, John P.

    1990-10-01

    The performance of limiter discriminator detection of M-ary FSK signals is analyzed at arbitrary modulation indices. It is shown that the error rate performance of limiter discriminator detection can be significantly improved by increasing the modulation index above 1/M. The optimum modulation index that minimizes the overall error probability is determined for the cases M = 2, 4 and 8. The analysis is carried out for wideband and bandlimited channels with Gaussian and second-order Butterworth filters. It is shown that the optimum modulation index depends on the signal/noise ratio (SNR), in a wideband channel, and on both SNR and time-bandwidth product in a bandlimited channel. Finally, it is shown that the optimum sampling instance in presence of a nonzero phase IF filter can be approximately determined by using only the worst case symbol pattern.

  15. 40 CFR Table 9 to Subpart Xxxx of... - Minimum Data for Continuous Compliance With the Emission Limits for Tire Production Affected Sources

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Minimum Data for Continuous Compliance With the Emission Limits for Tire Production Affected Sources 9 Table 9 to Subpart XXXX of Part 63... Hazardous Air Pollutants: Rubber Tire Manufacturing Pt. 63, Subpt. XXXX, Table 9 Table 9 to Subpart XXXX of...

  16. Detection limit of 238U by gamma spectrometry

    International Nuclear Information System (INIS)

    Tartaglione, A.; Blostein, J.; Mayer, R

    2004-01-01

    The detection limit of 238 U was determined by gamma spectra measurements of a depleted uranium sample using four NaI(Tl) scintillators in a compact arrangement.The sample was shielded with 5 and 10 cm of lead.Two different methods for data processing were used and compared.It was established that an appropriate array of 40 detectors could establish the presence of 220 g of this material in only 5 minutes [es

  17. Accuracy, precision, and lower detection limits (a deficit reduction approach)

    International Nuclear Information System (INIS)

    Bishop, C.T.

    1993-01-01

    The evaluation of the accuracy, precision and lower detection limits of the determination of trace radionuclides in environmental samples can become quite sophisticated and time consuming. This in turn could add significant cost to the analyses being performed. In the present method, a open-quotes deficit reduction approachclose quotes has been taken to keep costs low, but at the same time provide defensible data. In order to measure the accuracy of a particular method, reference samples are measured over the time period that the actual samples are being analyzed. Using a Lotus spreadsheet, data are compiled and an average accuracy is computed. If pairs of reference samples are analyzed, then precision can also be evaluated from the duplicate data sets. The standard deviation can be calculated if the reference concentrations of the duplicates are all in the same general range. Laboratory blanks are used to estimate the lower detection limits. The lower detection limit is calculated as 4.65 times the standard deviation of a set of blank determinations made over a given period of time. A Lotus spreadsheet is again used to compile data and LDLs over different periods of time can be compared

  18. Optimum allocation of imaging time and minimum detectable activity in dual isotope blood pool subtraction indium-111 platelet imaging

    International Nuclear Information System (INIS)

    Machac, J.; Horowitz, S.F.; Goldsmith, S.J.; Fuster, V.

    1984-01-01

    Indium-111 labeled platelet imaging is a tool for detection of thrombus formation in vascular spaces. Dual isotope blood pool subtraction may help differentiate focal platelet accumulation from blood pool activity. This study used a computer model to calculate the minimum excess-to-blood pool platelet ratio (EX/BP) and the optimum dual isotope imaging times under varied conditions of lesion size. The model simulated usual human imaging doses of 500 μCi of In-111 platelets and 5mCi of Tc-99m labeled RBCs giving a reference cardiac blood pool region (100cc) of 10000 cpm for Tc-99m and 500 cpm for In-111. The total imaging time was fixed at 20 minutes, while the two isotope imaging times (TIn/TTc) were varied, as were the simulated lesion size (cc) and EX/BP. The relative error of the excess counts was calculated using propagation of error theory. At the critical level of detection, where the excess lesion counts equal 3 times the standard deviation, the optimum TIn/TTc and minimum Ex/BP were determined for each lesion size. For the smallest lesion size (0.1cc), the minimum detectable EX/BP ratio was 1.6, with the best TIn/TTC ratio of 18/2 minutes, and for large lesions, an EX/BP of 0.1, with a TIn/TTc of 16/4. This model provides an estimate of the sensitivity and optimizes imaging times in dual isotope subtraction platelet imaging. The model is adaptable to varying isotope doses, total imaging times and lesion size. This information will be helpful in future in- vivo imaging studies of intravascular thrombi in humans

  19. Minimum detection efficiencies for a loophole-free observable-asymmetric Bell-type test

    International Nuclear Information System (INIS)

    Garbarino, G.

    2010-01-01

    We discuss the problem of finding the most favorable conditions for closing the detection loophole in a test of local realism with a Bell inequality. For a generic nonmaximally entangled two-qubit state and two incompatible bases to be adopted for alternative measurements of two observables a and b on each party, we apply Hardy's proof of nonlocality without inequality and derive an Eberhard-like inequality. For an infinity of nonmaximally entangled states we find that it is possible to refute local realism by requiring perfect detection efficiency for only one of the two observables, say b, to be measured on each party: The test is free from the detection loophole for any value of the detection efficiency corresponding to the other observable a. The maximum tolerable noise in such a loophole-free observable-asymmetric test is also evaluated.

  20. Detection of colloidal silver chloride near solubility limit

    Science.gov (United States)

    Putri, K. Y.; Adawiah, R.

    2018-03-01

    Detection of nanoparticles in solution has been made possible by several means; one of them is laser-induced breakdown detection (LIBD). LIBD is able to distinguish colloids of various sizes and concentrations. This technique has been used in several solubility studies. In this study, the formation of colloids in a mixed system of silver nitrate and sodium chloride was observed by acoustic LIBD. Silver chloride has low solubility limit, therefore LIBD measurement is appropriate. Silver and chloride solutions with equal concentrations, set at below and above the solubility of silver chloride as the expected solid product, were mixed and the resulting colloids were observed. The result of LIBD measurement showed that larger particles were present as more silver and chloride introduced. However, once the concentrations exceeded the solubility limit of silver chloride, the detected particle size seemed to be decreasing, hence suggested the occurrence of coprecipitation process. This phenomenon indicated that the ability of LIBD to detect even small changes in colloid amounts might be a useful tool in study on formation and stability of colloids, i.e. to confirm whether nanoparticles synthesis has been successfully performed and whether the system is stable or not.

  1. Aerosol quantification with the Aerodyne Aerosol Mass Spectrometer: detection limits and ionizer background effects

    Directory of Open Access Journals (Sweden)

    S. Borrmann

    2009-02-01

    Full Text Available Systematic laboratory experiments were performed to investigate quantification of various species with two versions of the Aerodyne Aerosol Mass Spectrometer, a Quadrupole Aerosol Mass Spectrometer (Q-AMS and a compact Time-of-Flight Aerosol Mass Spectrometer (c-ToF-AMS. Here we present a new method to continuously determine the detection limits of the AMS analyzers during regular measurements, yielding detection limit (DL information under various measurement conditions. Minimum detection limits range from 0.03 μg m−3 (nitrate, sulfate, and chloride up to 0.5 μg m−3 (organics for the Q-AMS. Those of the c-ToF-AMS are found between 0.003 μg m−3 (nitrate, sulfate and 0.03 μg m−3 (ammonium, organics. The DL values found for the c-ToF-AMS were ~10 times lower than those of the Q-AMS, mainly due to differences in ion duty cycle. Effects causing an increase of the detection limits include long-term instrument contamination, measurement of high aerosol mass concentrations and short-term instrument history. The self-cleaning processes which reduce the instrument background after measurement of large aerosol concentrations as well as the influences of increased instrument background on mass concentration measurements are discussed. Finally, improvement of detection limits by extension of averaging time intervals, selected or reduced ion monitoring, and variation of particle-to-background measurement ratio are investigated.

  2. Probe-Specific Procedure to Estimate Sensitivity and Detection Limits for 19F Magnetic Resonance Imaging.

    Directory of Open Access Journals (Sweden)

    Alexander J Taylor

    Full Text Available Due to low fluorine background signal in vivo, 19F is a good marker to study the fate of exogenous molecules by magnetic resonance imaging (MRI using equilibrium nuclear spin polarization schemes. Since 19F MRI applications require high sensitivity, it can be important to assess experimental feasibility during the design stage already by estimating the minimum detectable fluorine concentration. Here we propose a simple method for the calibration of MRI hardware, providing sensitivity estimates for a given scanner and coil configuration. An experimental "calibration factor" to account for variations in coil configuration and hardware set-up is specified. Once it has been determined in a calibration experiment, the sensitivity of an experiment or, alternatively, the minimum number of required spins or the minimum marker concentration can be estimated without the need for a pilot experiment. The definition of this calibration factor is derived based on standard equations for the sensitivity in magnetic resonance, yet the method is not restricted by the limited validity of these equations, since additional instrument-dependent factors are implicitly included during calibration. The method is demonstrated using MR spectroscopy and imaging experiments with different 19F samples, both paramagnetically and susceptibility broadened, to approximate a range of realistic environments.

  3. Probe-Specific Procedure to Estimate Sensitivity and Detection Limits for 19F Magnetic Resonance Imaging.

    Science.gov (United States)

    Taylor, Alexander J; Granwehr, Josef; Lesbats, Clémentine; Krupa, James L; Six, Joseph S; Pavlovskaya, Galina E; Thomas, Neil R; Auer, Dorothee P; Meersmann, Thomas; Faas, Henryk M

    2016-01-01

    Due to low fluorine background signal in vivo, 19F is a good marker to study the fate of exogenous molecules by magnetic resonance imaging (MRI) using equilibrium nuclear spin polarization schemes. Since 19F MRI applications require high sensitivity, it can be important to assess experimental feasibility during the design stage already by estimating the minimum detectable fluorine concentration. Here we propose a simple method for the calibration of MRI hardware, providing sensitivity estimates for a given scanner and coil configuration. An experimental "calibration factor" to account for variations in coil configuration and hardware set-up is specified. Once it has been determined in a calibration experiment, the sensitivity of an experiment or, alternatively, the minimum number of required spins or the minimum marker concentration can be estimated without the need for a pilot experiment. The definition of this calibration factor is derived based on standard equations for the sensitivity in magnetic resonance, yet the method is not restricted by the limited validity of these equations, since additional instrument-dependent factors are implicitly included during calibration. The method is demonstrated using MR spectroscopy and imaging experiments with different 19F samples, both paramagnetically and susceptibility broadened, to approximate a range of realistic environments.

  4. MINIMUM REQUIREMENTS FOR DETECTING A STOCHASTIC GRAVITATIONAL WAVE BACKGROUND USING PULSARS

    International Nuclear Information System (INIS)

    Cordes, J. M.; Shannon, R. M.

    2012-01-01

    We assess the detectability of a nanohertz gravitational wave (GW) background in a pulsar timing array (PTA) program by considering the shape and amplitude of the cross-correlation function summed over pulsar pairs. The distribution of correlation amplitudes is found to be non-Gaussian and highly skewed, which significantly influences detection and false-alarm probabilities. When only white noise combines with GWs in timing data, our detection results are consistent with those found by others. Contamination by red noise from spin variations and from any uncorrected interstellar plasma effects significantly increases the false-alarm probability. The number of arrival times (and thus the observing cadence) is important only as long as the residuals are dominated by white noise. When red noise and GWs dominate, the statistical significance of the correlation estimate can be improved only by increasing the number of pulsars. We characterize plausible detection regimes by evaluating the number of millisecond pulsars (MSPs) that must be monitored in a high-cadence, five-year timing program to detect a GW background spectrum h c (f) = A(f/f 0 ) –2/3 with f 0 = 1 yr –1 and A = 10 –15 . Our results indicate that a sample of 20 super-stable MSPs—those with rms timing residuals σ r ∼ –15 ) from red-noise contributions over a five-year span—will allow detection of the GW background and study of its spectrum. However, a timing program on ∼> 50-100 MSPs is likely needed for a complete PTA program, particularly if red noise is generally present in MSPs.

  5. Weighted Polynomial Approximation for Automated Detection of Inspiratory Flow Limitation

    Directory of Open Access Journals (Sweden)

    Sheng-Cheng Huang

    2017-01-01

    Full Text Available Inspiratory flow limitation (IFL is a critical symptom of sleep breathing disorders. A characteristic flattened flow-time curve indicates the presence of highest resistance flow limitation. This study involved investigating a real-time algorithm for detecting IFL during sleep. Three categories of inspiratory flow shape were collected from previous studies for use as a development set. Of these, 16 cases were labeled as non-IFL and 78 as IFL which were further categorized into minor level (20 cases and severe level (58 cases of obstruction. In this study, algorithms using polynomial functions were proposed for extracting the features of IFL. Methods using first- to third-order polynomial approximations were applied to calculate the fitting curve to obtain the mean absolute error. The proposed algorithm is described by the weighted third-order (w.3rd-order polynomial function. For validation, a total of 1,093 inspiratory breaths were acquired as a test set. The accuracy levels of the classifications produced by the presented feature detection methods were analyzed, and the performance levels were compared using a misclassification cobweb. According to the results, the algorithm using the w.3rd-order polynomial approximation achieved an accuracy of 94.14% for IFL classification. We concluded that this algorithm achieved effective automatic IFL detection during sleep.

  6. Efficiency calibration and minimum detectable activity concentration of a real-time UAV airborne sensor system with two gamma spectrometers

    International Nuclear Information System (INIS)

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-01-01

    A small-sized UAV (NH-UAV) airborne system with two gamma spectrometers (LaBr_3 detector and HPGe detector) was developed to monitor activity concentration in serious nuclear accidents, such as the Fukushima nuclear accident. The efficiency calibration and determination of minimum detectable activity concentration (MDAC) of the specific system were studied by MC simulations at different flight altitudes, different horizontal distances from the detection position to the source term center and different source term sizes. Both air and ground radiation were considered in the models. The results obtained may provide instructive suggestions for in-situ radioactivity measurements of NH-UAV. - Highlights: • A small-sized UAV airborne sensor system was developed. • Three radioactive models were chosen to simulate the Fukushima accident. • Both the air and ground radiation were considered in the models. • The efficiency calculations and MDAC values were given. • The sensor system is able to monitor in serious nuclear accidents.

  7. Efficiency calibration and minimum detectable activity concentration of a real-time UAV airborne sensor system with two gamma spectrometers.

    Science.gov (United States)

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-04-01

    A small-sized UAV (NH-UAV) airborne system with two gamma spectrometers (LaBr3 detector and HPGe detector) was developed to monitor activity concentration in serious nuclear accidents, such as the Fukushima nuclear accident. The efficiency calibration and determination of minimum detectable activity concentration (MDAC) of the specific system were studied by MC simulations at different flight altitudes, different horizontal distances from the detection position to the source term center and different source term sizes. Both air and ground radiation were considered in the models. The results obtained may provide instructive suggestions for in-situ radioactivity measurements of NH-UAV. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Detection limits for nanoparticles in solution with classical turbidity spectra

    Science.gov (United States)

    Le Blevennec, G.

    2013-09-01

    Detection of nanoparticles in solution is required to manage safety and environmental problems. Spectral transmission turbidity method has now been known for a long time. It is derived from the Mie Theory and can be applied to any number of spheres, randomly distributed and separated by large distance compared to wavelength. Here, we describe a method for determination of size, distribution and concentration of nanoparticles in solution using UV-Vis transmission measurements. The method combines Mie and Beer Lambert computation integrated in a best fit approximation. In a first step, a validation of the approach is completed on silver nanoparticles solution. Verification of results is realized with Transmission Electronic Microscopy measurements for size distribution and an Inductively Coupled Plasma Mass Spectrometry for concentration. In view of the good agreement obtained, a second step of work focuses on how to manage the concentration to be the most accurate on the size distribution. Those efficient conditions are determined by simple computation. As we are dealing with nanoparticles, one of the key points is to know what the size limits reachable are with that kind of approach based on classical electromagnetism. In taking into account the transmission spectrometer accuracy limit we determine for several types of materials, metals, dielectrics, semiconductors the particle size limit detectable by such a turbidity method. These surprising results are situated at the quantum physics frontier.

  9. Detection limit for rate fluctuations in inhomogeneous Poisson processes

    Science.gov (United States)

    Shintani, Toshiaki; Shinomoto, Shigeru

    2012-04-01

    Estimations of an underlying rate from data points are inevitably disturbed by the irregular occurrence of events. Proper estimation methods are designed to avoid overfitting by discounting the irregular occurrence of data, and to determine a constant rate from irregular data derived from a constant probability distribution. However, it can occur that rapid or small fluctuations in the underlying density are undetectable when the data are sparse. For an estimation method, the maximum degree of undetectable rate fluctuations is uniquely determined as a phase transition, when considering an infinitely long series of events drawn from a fluctuating density. In this study, we analytically examine an optimized histogram and a Bayesian rate estimator with respect to their detectability of rate fluctuation, and determine whether their detectable-undetectable phase transition points are given by an identical formula defining a degree of fluctuation in an underlying rate. In addition, we numerically examine the variational Bayes hidden Markov model in its detectability of rate fluctuation, and determine whether the numerically obtained transition point is comparable to those of the other two methods. Such consistency among these three principled methods suggests the presence of a theoretical limit for detecting rate fluctuations.

  10. Detection limit for rate fluctuations in inhomogeneous Poisson processes.

    Science.gov (United States)

    Shintani, Toshiaki; Shinomoto, Shigeru

    2012-04-01

    Estimations of an underlying rate from data points are inevitably disturbed by the irregular occurrence of events. Proper estimation methods are designed to avoid overfitting by discounting the irregular occurrence of data, and to determine a constant rate from irregular data derived from a constant probability distribution. However, it can occur that rapid or small fluctuations in the underlying density are undetectable when the data are sparse. For an estimation method, the maximum degree of undetectable rate fluctuations is uniquely determined as a phase transition, when considering an infinitely long series of events drawn from a fluctuating density. In this study, we analytically examine an optimized histogram and a Bayesian rate estimator with respect to their detectability of rate fluctuation, and determine whether their detectable-undetectable phase transition points are given by an identical formula defining a degree of fluctuation in an underlying rate. In addition, we numerically examine the variational Bayes hidden Markov model in its detectability of rate fluctuation, and determine whether the numerically obtained transition point is comparable to those of the other two methods. Such consistency among these three principled methods suggests the presence of a theoretical limit for detecting rate fluctuations.

  11. Limits of detection of americium-241 in air

    International Nuclear Information System (INIS)

    Bereznai, T.

    1995-01-01

    Seven semiconductor detectors with various characteristics (type, form, size, etc.) were tested and compared in gamma-spectrometric assays for Am-241 aerosols in air. The problem at hand (determining a low activity or attaining a set detection limit (approx. 2 mBq/m 3 ) as soon as possible after sampling) was solved best by a large-volume n-type detector with a Be-window. In addition to the detector parameters commonly used (energy resolution and effectiveness), the peak-to-background ratio and the background counting rate at the gamma-energy of the nuclide to be determined are important criteria influencing the choice of equipment. (orig.) [de

  12. CARIES DETECTION WITH LASER FLUORESCENCE DEVICES. LIMITATIONS OF THEIR USE

    Directory of Open Access Journals (Sweden)

    Andreas Spaveras

    2017-03-01

    Data synthesis: DD and DDPen are useful devices for caries detection on the occlusal tooth surfaces. Their main advantages are the very high reproducibility of measurements (>0.90, the ease of handling and the quantification and monitoring capacity. Their main limitations are the relatively low specificity for enamel lesions, the necessity of unstained surfaces and absence of plaque and pastes during measurements and the absence of a universal, clinically functional calibration value (COV. Conclusion: Further studies are required for more reliable data analysis and clinical interpretation of the relevant results.

  13. Determination and Interpretation of Characteristic Limits for Radioactivity Measurements: Decision Threshhold, Detection Limit and Limits of the Confidence Interval

    International Nuclear Information System (INIS)

    2017-01-01

    Since 2004, the environment programme of the IAEA has included activities aimed at developing a set of procedures for analytical measurements of radionuclides in food and the environment. Reliable, comparable and fit for purpose results are essential for any analytical measurement. Guidelines and national and international standards for laboratory practices to fulfil quality assurance requirements are extremely important when performing such measurements. The guidelines and standards should be comprehensive, clearly formulated and readily available to both the analyst and the customer. ISO 11929:2010 is the international standard on the determination of the characteristic limits (decision threshold, detection limit and limits of the confidence interval) for measuring ionizing radiation. For nuclear analytical laboratories involved in the measurement of radioactivity in food and the environment, robust determination of the characteristic limits of radioanalytical techniques is essential with regard to national and international regulations on permitted levels of radioactivity. However, characteristic limits defined in ISO 11929:2010 are complex, and the correct application of the standard in laboratories requires a full understanding of various concepts. This publication provides additional information to Member States in the understanding of the terminology, definitions and concepts in ISO 11929:2010, thus facilitating its implementation in Member State laboratories.

  14. The minimum mass of detectable planets in protoplanetary discs and the derivation of planetary masses from high-resolution observations.

    Science.gov (United States)

    Rosotti, Giovanni P; Juhasz, Attila; Booth, Richard A; Clarke, Cathie J

    2016-07-01

    We investigate the minimum planet mass that produces observable signatures in infrared scattered light and submillimetre (submm) continuum images and demonstrate how these images can be used to measure planet masses to within a factor of about 2. To this end, we perform multi-fluid gas and dust simulations of discs containing low-mass planets, generating simulated observations at 1.65, 10 and 850 μm. We show that the minimum planet mass that produces a detectable signature is ∼15 M ⊕ : this value is strongly dependent on disc temperature and changes slightly with wavelength (favouring the submm). We also confirm previous results that there is a minimum planet mass of ∼20 M ⊕ that produces a pressure maximum in the disc: only planets above this threshold mass generate a dust trap that can eventually create a hole in the submm dust. Below this mass, planets produce annular enhancements in dust outwards of the planet and a reduction in the vicinity of the planet. These features are in steady state and can be understood in terms of variations in the dust radial velocity, imposed by the perturbed gas pressure radial profile, analogous to a traffic jam. We also show how planet masses can be derived from structure in scattered light and submm images. We emphasize that simulations with dust need to be run over thousands of planetary orbits so as to allow the gas profile to achieve a steady state and caution against the estimation of planet masses using gas-only simulations.

  15. Minimum detectable activity and false alarm rate relationships for alpha continuous air monitors

    International Nuclear Information System (INIS)

    Hoover, M.D.; Newton, G.J.

    1994-01-01

    The U.S. Department of Energy rule for Occupational Radiation Protection (10 CFR Part 835, December 1993) and the DOE Radiological Control Manual (the RCM) (DOE/EH-0256T, Rev. 1, April 1994) require the use of continuous air monitors (CAMs) in normally occupied areas where an individual is likely to be exposed to a concentration of airborne radioactivity exceeding the derived air concentration (DAC) or where there is a need to alert potentially exposed individuals to unexpected increases in airborne radioactivity levels. The DAC is the airborne concentration that equals the annual limit on intake divided by the volume of air breathed by an average worker for a working year of 2000 h (assuming a breathing volume of 2400 m 3 ). It is equivalent to the airborne concentration to which a worker could be exposed for an entire working year (2000 h) without exceeding the allowable annual limit on intake. The rule and the RCM further require that real-time air monitors have an alarm capability and sufficient sensitivity to alert potentially exposed individuals that immediate action is necessary in order to minimize or terminate inhalation exposures. The RCM also recommends that real-time air monitors should be capable of measuring 1 DAC when averaged over 8 h (8 DAC-h) under laboratory conditions. In response to these recommendations, we are developing procedures for determining the basic sensitivity of alpha CAMs under laboratory conditions and for documenting practical alarm set points for routine use of CAMs under a range of radon and thoron concentrations

  16. Optimal statistical damage detection and classification in an experimental wind turbine blade using minimum instrumentation

    Science.gov (United States)

    Hoell, Simon; Omenzetter, Piotr

    2017-04-01

    The increasing demand for carbon neutral energy in a challenging economic environment is a driving factor for erecting ever larger wind turbines in harsh environments using novel wind turbine blade (WTBs) designs characterized by high flexibilities and lower buckling capacities. To counteract resulting increasing of operation and maintenance costs, efficient structural health monitoring systems can be employed to prevent dramatic failures and to schedule maintenance actions according to the true structural state. This paper presents a novel methodology for classifying structural damages using vibrational responses from a single sensor. The method is based on statistical classification using Bayes' theorem and an advanced statistic, which allows controlling the performance by varying the number of samples which represent the current state. This is done for multivariate damage sensitive features defined as partial autocorrelation coefficients (PACCs) estimated from vibrational responses and principal component analysis scores from PACCs. Additionally, optimal DSFs are composed not only for damage classification but also for damage detection based on binary statistical hypothesis testing, where features selections are found with a fast forward procedure. The method is applied to laboratory experiments with a small scale WTB with wind-like excitation and non-destructive damage scenarios. The obtained results demonstrate the advantages of the proposed procedure and are promising for future applications of vibration-based structural health monitoring in WTBs.

  17. Determination of limits for smallest detectable and largest subcritical leakage cracks in piping systems

    International Nuclear Information System (INIS)

    Bieselt, R.; Wolf, M.

    1995-01-01

    Nuclear power plant piping systems - those still in their original as-built condition as well as upgraded designs - are subject to safety analysis. In order to limit the consequences of postulated piping failures, the basic safety concept incorporating rupture preclusion criteria is applied to specific high-energy piping systems. Leak-before-break analyses are also conducted within the framework of this concept. These analyses serve to determine the potential consequences of jet and reaction forces due to maximum subcritical leakage cracks while also establishing the minimum crack sizes that would be reliably detectable by the leakage rates resulting from these cracks. The boundary conditions for these analyses are not clearly defined. Using various examples as a basis, this paper presents and discusses how the leak-before-break concept can be applied. (orig.)

  18. Limits of detection in instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Guinn, V.P.

    1990-01-01

    Lower limits of detection (LLODs), frequently referred to simply as limits of detection and abbreviated as LODs, often appear in the literature of analytical chemistry - for numerous different methods of elemental and/or molecular analysis. In this chapter, one particular method of quantitative elemental analysis, that of instrumental neutron activation analysis (INAA), is the subject discussed, with reference to LODs. Particularly in the literature of neutron activation analysis (NAA), many tables of 'interference-free' NAA LODs are available. Not all of these are of much use, because (1) for many the definition used for LOD is not clear, or reasonable, (2) for many, the analysis conditions used are not clearly specified, and (3) for many, the analysis conditions used are specified, but not very practicable for most laboratories. For NAA work, such tables of interference-free LODs are, in any case, only applicable to samples in which, at the time of counting, only one radionuclide is present to any significant extent in the activated sample. It is important to note that tables of INAA LODs, per se, do not exist - since the LOD for a given element, under stated analysis conditions, can vary by orders of magnitude, depending on the elemental composition of the matrix in which it is present. For any given element, its INAA LOD will always be as large as, and usually much larger than, its tabulated 'interference-free' NAA LOD - how much larger depending upon the elemental composition of the matrix in which it is present. As discussed in this chapter, however, an INAA computer program exists that can calculate realistic INAA LODs for any elements of interest, in any kind of specified sample matrix, under any given set of analysis conditions

  19. TXRF 'measurements' of concentration distribution below the detection limit

    International Nuclear Information System (INIS)

    Kubala-Kukus, A.; Banas, D.; Braziewicz, J.; Majewska, U.; Mrowczynski, S.; Pajek, M.

    2000-01-01

    We demonstrate that a shape of the concentration distribution of the element in a set of samples, as measured by the TXRF method, can be determined even for the concentrations below the detection limit (DL). This can be done, when the measurements reporting the concentration below DL level are included properly in the analysis of the results. The method developed for such correction is presented and discussed. It is demonstrated that this correction is particularly important when the studied concentrations are close to the DL level of the method, which is a common case for TXRF. In the paper a precision of the developed correction is discussed in details, by using the results of numerical simulations of experiments for different concentration distributions and number of performed measurements. It is demonstrated that the factor, which limits the accuracy of the correction, is the number of measurements, not the correction procedure itself. The applicability and importance of the developed correction is demonstrated for routine TXRF analysis of different types of samples of bio-medical interest. (author)

  20. Physiological techniques for detecting expiratory flow limitation during tidal breathing

    Directory of Open Access Journals (Sweden)

    N.G. Koulouris

    2011-09-01

    Full Text Available Patients with severe chronic obstructive pulmonary disease (COPD often exhale along the same flow–volume curve during quiet breathing as they do during the forced expiratory vital capacity manoeuvre, and this has been taken as an indicator of expiratory flow limitation at rest (EFLT. Therefore, EFLT, namely attainment of maximal expiratory flow during tidal expiration, occurs when an increase in transpulmonary pressure causes no increase in expiratory flow. EFLT leads to small airway injury and promotes dynamic pulmonary hyperinflation, with concurrent dyspnoea and exercise limitation. In fact, EFLT occurs commonly in COPD patients (mainly in Global Initiative for Chronic Obstructive Lung Disease III and IV stage, in whom the latter symptoms are common, but is not exclusive to COPD, since it can also be detected in other pulmonary and nonpulmonary diseases like asthma, acute respiratory distress syndrome, heart failure and obesity, etc. The existing up to date physiological techniques of assessing EFLT are reviewed in the present work. Among the currently available techniques, the negative expiratory pressure has been validated in a wide variety of settings and disorders. Consequently, it should be regarded as a simple, noninvasive, practical and accurate new technique.

  1. Optimising Mycobacterium tuberculosis detection in resource limited settings.

    Science.gov (United States)

    Alfred, Nwofor; Lovette, Lawson; Aliyu, Gambo; Olusegun, Obasanya; Meshak, Panwal; Jilang, Tunkat; Iwakun, Mosunmola; Nnamdi, Emenyonu; Olubunmi, Onuoha; Dakum, Patrick; Abimiku, Alash'le

    2014-03-03

    The light-emitting diode (LED) fluorescence microscopy has made acid-fast bacilli (AFB) detection faster and efficient although its optimal performance in resource-limited settings is still being studied. We assessed the optimal performances of light and fluorescence microscopy in routine conditions of a resource-limited setting and evaluated the digestion time for sputum samples for maximum yield of positive cultures. Cross-sectional study. Facility-based involving samples of routine patients receiving tuberculosis treatment and care from the main tuberculosis case referral centre in northern Nigeria. The study included 450 sputum samples from 150 new patients with clinical diagnosis of pulmonary tuberculosis. The 450 samples were pooled into 150 specimens, examined independently with mercury vapour lamp (FM), LED CysCope (CY) and Primo Star iLED (PiLED) fluorescence microscopies, and with the Ziehl-Neelsen (ZN) microscopy to assess the performance of each technique compared with liquid culture. The cultured specimens were decontaminated with BD Mycoprep (4% NaOH-1% NLAC and 2.9% sodium citrate) for 10, 15 and 20 min before incubation in Mycobacterium growth incubator tube (MGIT) system and growth examined for acid-fast bacilli (AFB). Of the 150 specimens examined by direct microscopy: 44 (29%), 60 (40%), 49 (33%) and 64 (43%) were AFB positive by ZN, FM, CY and iLED microscopy, respectively. Digestion of sputum samples for 10, 15 and 20 min yielded mycobacterial growth in 72 (48%), 81 (54%) and 68 (45%) of the digested samples, respectively, after incubation in the MGIT system. In routine laboratory conditions of a resource-limited setting, our study has demonstrated the superiority of fluorescence microscopy over the conventional ZN technique. Digestion of sputum samples for 15 min yielded more positive cultures.

  2. [Comparison of the "Trigger" tool with the minimum basic data set for detecting adverse events in general surgery].

    Science.gov (United States)

    Pérez Zapata, A I; Gutiérrez Samaniego, M; Rodríguez Cuéllar, E; Gómez de la Cámara, A; Ruiz López, P

    Surgery is a high risk for the occurrence of adverse events (AE). The main objective of this study is to compare the effectiveness of the Trigger tool with the Hospital National Health System registration of Discharges, the minimum basic data set (MBDS), in detecting adverse events in patients admitted to General Surgery and undergoing surgery. Observational and descriptive retrospective study of patients admitted to general surgery of a tertiary hospital, and undergoing surgery in 2012. The identification of adverse events was made by reviewing the medical records, using an adaptation of "Global Trigger Tool" methodology, as well as the (MBDS) registered on the same patients. Once the AE were identified, they were classified according to damage and to the extent to which these could have been avoided. The area under the curve (ROC) were used to determine the discriminatory power of the tools. The Hanley and Mcneil test was used to compare both tools. AE prevalence was 36.8%. The TT detected 89.9% of all AE, while the MBDS detected 28.48%. The TT provides more information on the nature and characteristics of the AE. The area under the curve was 0.89 for the TT and 0.66 for the MBDS. These differences were statistically significant (P<.001). The Trigger tool detects three times more adverse events than the MBDS registry. The prevalence of adverse events in General Surgery is higher than that estimated in other studies. Copyright © 2017 SECA. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Neutron activation analysis detection limits using 252Cf sources

    International Nuclear Information System (INIS)

    DiPrete, D.P.; Sigg, R.A.

    2000-01-01

    The Savannah River Technology Center (SRTC) developed a neutron activation analysis (NAA) facility several decades ago using low-flux 252 Cf neutron sources. Through this time, the facility has addressed areas of applied interest in managing the Savannah River Site (SRS). Some applications are unique because of the site's operating history and its chemical-processing facilities. Because sensitivity needs for many applications are not severe, they can be accomplished using an ∼6-mg 252 Cf NAA facility. The SRTC 252 Cf facility continues to support applied research programs at SRTC as well as other SRS programs for environmental and waste management customers. Samples analyzed by NAA include organic compounds, metal alloys, sediments, site process solutions, and many other materials. Numerous radiochemical analyses also rely on the facility for production of short-lived tracers, yielding by activation of carriers and small-scale isotope production for separation methods testing. These applications are more fully reviewed in Ref. 1. Although the flux [approximately2 x 10 7 n/cm 2 ·s] is low relative to reactor facilities, more than 40 elements can be detected at low and sub-part-per-million levels. Detection limits provided by the facility are adequate for many analytical projects. Other multielement analysis methods, particularly inductively coupled plasma atomic emission and inductively coupled plasma mass spectrometry, can now provide sensitivities on dissolved samples that are often better than those available by NAA using low-flux isotopic sources. Because NAA allows analysis of bulk samples, (a) it is a more cost-effective choice when its sensitivity is adequate than methods that require digestion and (b) it eliminates uncertainties that can be introduced by digestion processes

  4. Current limitations and challenges in nanowaste detection, characterisation and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Part, Florian; Zecha, Gudrun [Department of Water-Atmosphere-Environment, University of Natural Resources and Life Sciences, Institute of Waste Management, Muthgasse 107, 1190 Vienna (Austria); Causon, Tim [Department of Chemistry, Division of Analytical Chemistry, University of Natural Resources and Life Sciences, Muthgasse 18, 1190 Vienna (Austria); Sinner, Eva-Kathrin [Department of Nanobiotechnology, Institute for Synthetic Bioarchitectures, University of Natural Resources and Life Sciences, Muthgasse 11/II, 1190 Vienna (Austria); Huber-Humer, Marion, E-mail: marion.huber-humer@boku.ac.at [Department of Water-Atmosphere-Environment, University of Natural Resources and Life Sciences, Institute of Waste Management, Muthgasse 107, 1190 Vienna (Austria)

    2015-09-15

    Highlights: • First review on detection of nanomaterials in complex waste samples. • Focus on nanoparticles in solid, liquid and gaseous waste samples. • Summary of current applicable methods for nanowaste detection and characterisation. • Limitations and challenges of characterisation of nanoparticles in waste. - Abstract: Engineered nanomaterials (ENMs) are already extensively used in diverse consumer products. Along the life cycle of a nano-enabled product, ENMs can be released and subsequently accumulate in the environment. Material flow models also indicate that a variety of ENMs may accumulate in waste streams. Therefore, a new type of waste, so-called nanowaste, is generated when end-of-life ENMs and nano-enabled products are disposed of. In terms of the precautionary principle, environmental monitoring of end-of-life ENMs is crucial to allow assessment of the potential impact of nanowaste on our ecosystem. Trace analysis and quantification of nanoparticulate species is very challenging because of the variety of ENM types that are used in products and low concentrations of nanowaste expected in complex environmental media. In the framework of this paper, challenges in nanowaste characterisation and appropriate analytical techniques which can be applied to nanowaste analysis are summarised. Recent case studies focussing on the characterisation of ENMs in waste streams are discussed. Most studies aim to investigate the fate of nanowaste during incineration, particularly considering aerosol measurements; whereas, detailed studies focusing on the potential release of nanowaste during waste recycling processes are currently not available. In terms of suitable analytical methods, separation techniques coupled to spectrometry-based methods are promising tools to detect nanowaste and determine particle size distribution in liquid waste samples. Standardised leaching protocols can be applied to generate soluble fractions stemming from solid wastes, while

  5. Lower detectable limit of sulfur by fast neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Shani, G; Cohen, D [Ben-Gurion Univ. of the Negev, Beersheba (Israel). Dept. of Nuclear Engineering

    1976-07-01

    For the purpose of air pollution research, the possibility of fast neutron activation analysis of sulfur was investigated. The only reaction that can be used for this purpose is S/sup 34/(n, p)P/sup 34/. A rabbit system was installed, synchronized with a 150 kV D-T neutron generator and an electronic analysing system. The whole system was operated so that the sample was irradiated for 10 sec and the 2.13 MeV ..gamma..-ray was counted for 10 sec. 5 samples were prepared containing sulfur from 0.5 to 0.1 g. Each measurement lasted 30 min and the activity was plotted as a function of sulfur weight. The relative error is increased very much when the amount of sulfur is below 0.1 g. This is what sets the lower detectable limit. Collection of more than 0.1 g of sulfur even during a long collection time means a very high SO/sub 2/ concentration in the air.

  6. Improved detection limits for electrospray ionization on a magnetic sector mass spectrometer by using an array detector.

    Science.gov (United States)

    Cody, R B; Tamura, J; Finch, J W; Musselman, B D

    1994-03-01

    Array detection was compared with point detection for solutions of hen egg-white lysozyme, equine myoglobin, and ubiquitin analyzed by electrospray ionization with a magnetic sector mass spectrometer. The detection limits for samples analyzed by using the array detector system were at least 10 times lower than could be achieved by using a point detector on the same mass spectrometer. The minimum detectable quantity of protein corresponded to a signal-to-background ratio of approximately 2∶1 for a 500 amol/μL solution of hen egg-white lysozyme. However, the ultimate practical sample concentrations appeared to be in the 10-100 fmol/μL range for the analysis of dilute solutions of relatively pure proteins or simple mixtures.

  7. The influence of random and systematic errors on a general definition of minimum detectable amount (MDA) applicable to all radiobioassay measurements

    International Nuclear Information System (INIS)

    Brodsky, A.

    1985-01-01

    An approach to defining minimum detectable amount (MDA) of radioactivity in a sample will be discussed, with the aim of obtaining comments helpful in developing a formulation of MDA that will be broadly applicable to all kinds of radiobioassay measurements, and acceptable to the scientists who make these measurements. Also, the influence of random and systematic errors on the defined MDA are examined

  8. Limited irrigation research and infrared thermometry for detecting water stress

    Science.gov (United States)

    The USDA-ARS Limited Irrigation Research Farm, located outside of Greeley Colorado, is an experiment evaluating management perspectives of limited irrigation water. An overview of the farm systems is shown, including drip irrigation systems, water budgeting, and experimental design, as well as preli...

  9. Determination of detection limits for a VPD ICPMS method of analysis; Determination des limites de detection d'une methode d'analyse VPD ICPMS

    Energy Technology Data Exchange (ETDEWEB)

    Badard, M.; Veillerot, M

    2007-07-01

    This training course report presents the different methods of detection and quantifying of metallic impurities in semiconductors. One of the most precise technique is the collection of metal impurities by vapor phase decomposition (VPD) followed by their analysis by ICPMS (inductively coupled plasma mass spectrometry). The study shows the importance of detection limits in the domain of chemical analysis and the way to determine them for the ICPMS analysis. The results found on detection limits are excellent. Even if the detection limits reached with ICPMS performed after manual or automatic VPD are much higher than detection limits of ICPMS alone, this method remains one of the most sensible for ultra-traces analysis. (J.S.)

  10. DETECTING ALIEN LIMIT CYCLES NEAR A HAMILTONIAN 2-SADDLE CYCLE

    OpenAIRE

    LUCA, Stijn; DUMORTIER, Freddy; Caubergh, M.; Roussarie, R.

    2009-01-01

    This paper aims at providing and example of a cubic Hamiltonian 2-saddle cycle that after bifurcation can give rise to an alien limit cycle; this is a limit cycle that is not controlled by a zero of the related Abelian integral. To guarantee the existence of an alien limit cycle one can verify generic conditions on the Abelian integral and on the transition map associated to the connections of the 2-saddle cycle. In this paper, a general method is developed to compute the first and second der...

  11. Detection limits of intraoperative near infrared imaging for tumor resection.

    Science.gov (United States)

    Thurber, Greg M; Figueiredo, Jose-Luiz; Weissleder, Ralph

    2010-12-01

    The application of fluorescent molecular imaging to surgical oncology is a developing field with the potential to reduce morbidity and mortality. However, the detection thresholds and other requirements for successful intervention remain poorly understood. Here we modeled and experimentally validated depth and size of detection of tumor deposits, trade-offs in coverage and resolution of areas of interest, and required pharmacokinetics of probes based on differing levels of tumor target presentation. Three orthotopic tumor models were imaged by widefield epifluorescence and confocal microscopes, and the experimental results were compared with pharmacokinetic models and light scattering simulations to determine detection thresholds. Widefield epifluorescence imaging can provide sufficient contrast to visualize tumor margins and detect tumor deposits 3-5  mm deep based on labeled monoclonal antibodies at low objective magnification. At higher magnification, surface tumor deposits at cellular resolution are detectable at TBR ratios achieved with highly expressed antigens. A widefield illumination system with the capability for macroscopic surveying and microscopic imaging provides the greatest utility for varying surgical goals. These results have implications for system and agent designs, which ultimately should aid complete resection in most surgical beds and provide real-time feedback to obtain clean margins. © 2010 Wiley-Liss, Inc.

  12. Physics of detecting torsion and placing limits on its effects

    International Nuclear Information System (INIS)

    Stoeger, W.R.

    1985-01-01

    The essential principles of torsion-detection physics are presented, and an evaluation is conducted of several conceivable types of experiments and observations for actually detecting torsion fields, reemphasizing also the evident impossibility of successfully searching for its manifestations among cosmological relics. In particular, a polarized body, with net intrinsic (fundamental-particle) spin, is essential for detecting a torsion field. One which possesses only orbital angular momentum - rotation - or an unpolarized intrinsic spin density will not feel torsion. The fundamental problem in searching for such fields is the extremely small basic unit of the coupling or interaction energy between the torsion field and spin. The best way of maximizing the total interaction energy is to increase the spin density of the source sigma-s and at the same time the spin number SD of the detector. 15 references

  13. Importance of the lower limit of detection in radiological safety; Importancia del limite inferior de deteccion en seguridad radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Rafael, Terol T; Hermenegildo, Maldonado M [Comision Nacional de Seguridad Nuclear y Salvaguardias (Mexico)

    1991-07-01

    The concept of the Lower Limit of Detection (LLD) it contributes in the solution of some problems related with the radiological safety, such as the realization of the tests of flight of the sealed radioactive sources; the determination of radioisotopes in environmental samples; the estimate of present radionuclides in polluted foods; in general, the detection of small quantities of radioactive materials present in materials of use or consumption by part of the man in his daily life; as the one Lower Limit of Detection is related with topics of statistics, in this work a small review of them is made, it was superficially discussed the mensuration problems related with the establishment of the Lower Limit of Detection.

  14. SU-F-J-206: Systematic Evaluation of the Minimum Detectable Shift Using a Range- Finding Camera

    Energy Technology Data Exchange (ETDEWEB)

    Platt, M; Platt, M [College of Medicine University of Cincinnati, Cincinnati, OH (United States); Lamba, M [University of Cincinnati, Cincinnati, OH (United States); Mascia, A [University of Cincinnati Medical Center, Cincinnati, OH (United States); Huang, K [UC Health Barret Cancer Center, Cincinnati, OH (United States)

    2016-06-15

    Purpose: The robotic table used for patient alignment in proton therapy is calibrated only at commissioning under well-defined conditions and table shifts may vary over time and with differing conditions. The purpose of this study is to systematically investigate minimum detectable shifts using a time-of-flight (TOF) range-finding camera for table position feedback. Methods: A TOF camera was used to acquire one hundred 424 × 512 range images from a flat surface before and after known shifts. Range was assigned by averaging central regions of the image across multiple images. Depth resolution was determined by evaluating the difference between the actual shift of the surface and the measured shift. Depth resolution was evaluated for number of images averaged, area of sensor over which depth was averaged, distance from camera to surface, central versus peripheral image regions, and angle of surface relative to camera. Results: For one to one thousand images with a shift of one millimeter the range in error was 0.852 ± 0.27 mm to 0.004 ± 0.01 mm (95% C.I.). For varying regions of the camera sensor the range in error was 0.02 ± 0.05 mm to 0.47 ± 0.04 mm. The following results are for 10 image averages. For areas ranging from one pixel to 9 × 9 pixels the range in error was 0.15 ± 0.09 to 0.29 ± 0.15 mm (1σ). For distances ranging from two to four meters the range in error was 0.15 ± 0.09 to 0.28 ± 0.15 mm. For an angle of incidence between thirty degrees and ninety degrees the average range in error was 0.11 ± 0.08 to 0.17 ± 0.09 mm. Conclusion: It is feasible to use a TOF camera for measuring shifts in flat surfaces under clinically relevant conditions with submillimeter precision.

  15. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R., E-mail: meirelesls@cdtn.br, E-mail: masl@cdtn.br, E-mail: lcmb@cdtn.br, E-mail: hrf@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  16. Study of the influence of the time temperature profile on the minimum detectable dose of TLD-100

    International Nuclear Information System (INIS)

    Meireles, Leonardo S.; Lacerda, Marco Aurelio S.; Meira-Belo, Luiz C.; Ferreira, Hudson R.

    2013-01-01

    Monitoring of workers and workplaces is an integral part of any radiation protection programme (RPP). It is essential to demonstrate compliance with regulations that limit the allowable dose to the public from manmade sources and to enable the responsible of the installations to verify compliance with the legal dose limits to the workers and ALARA goals. Thermoluminescent dosemeters (TLDs) are generally employed to assess the environmental and personnel doses. To completely characterize a TLD dosimetry system is fundamental to determine the Lowest Dose that the system is capable of measuring. As the amount of the light emitted by TLD material is a function of the time temperature profile (TTP), in the present study, the influence of the TTP on the Detection Threshold (MDD) of the LiF:Mg,Ti (TLD-100) detectors was evaluated. Eighteen different TTPs were tested for two different annealing processes: (I) utilization of the TTP itself and; (II) a microprocessor controlled oven annealing procedure. Results showed that TTP choice can influence significantly in the MDD values. The worst results were generally found for TLDs annealed by the TTP itself. The lack of pattern or the unexpected behavior to the influence of some parameters of the TTP on the calculated MDDs must be carefully investigated. Greater variations on the TTP parameters must be undertaken. Special attention must be also done on the methodology of calculating the MDDs. (author)

  17. Evaluation of uncertainty and detection limits in radioactivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Herranz, M. [Universidad del Pais Vasco/Euskal Herriko Unibertsitatea, Escuela Tecnica Superior de Ingenieria de Bilbao, Alda. Urquijo, s/n, 48013 Bilbao (Spain); Idoeta, R. [Universidad del Pais Vasco/Euskal Herriko Unibertsitatea, Escuela Tecnica Superior de Ingenieria de Bilbao, Alda. Urquijo, s/n, 48013 Bilbao (Spain)], E-mail: raquel.idoeta@ehu.es; Legarda, F. [Universidad del Pais Vasco/Euskal Herriko Unibertsitatea, Escuela Tecnica Superior de Ingenieria de Bilbao, Alda. Urquijo, s/n, 48013 Bilbao (Spain)

    2008-10-01

    The uncertainty associated with the assessment of the radioactive content of any sample depends on the net counting rate registered during the measuring process and on the different weighting factors needed to transform this counting rate into activity, activity per unit mass or activity concentration. This work analyses the standard uncertainties in these weighting factors as well as their contribution to the uncertainty in the activity reported for three typical determinations for environmental radioactivity measurements in the laboratory. It also studies the corresponding characteristic limits and their dependence on the standard uncertainty related to those weighting factors, offering an analysis of the effectiveness of the simplified characteristic limits as evaluated by various measuring software and laboratories.

  18. Evaluation of uncertainty and detection limits in radioactivity measurements

    International Nuclear Information System (INIS)

    Herranz, M.; Idoeta, R.; Legarda, F.

    2008-01-01

    The uncertainty associated with the assessment of the radioactive content of any sample depends on the net counting rate registered during the measuring process and on the different weighting factors needed to transform this counting rate into activity, activity per unit mass or activity concentration. This work analyses the standard uncertainties in these weighting factors as well as their contribution to the uncertainty in the activity reported for three typical determinations for environmental radioactivity measurements in the laboratory. It also studies the corresponding characteristic limits and their dependence on the standard uncertainty related to those weighting factors, offering an analysis of the effectiveness of the simplified characteristic limits as evaluated by various measuring software and laboratories

  19. Minimum exposure limits and measured relationships between the vitamin D, erythema and international commission on non-ionizing radiation protection solar ultraviolet.

    Science.gov (United States)

    Downs, Nathan; Parisi, Alfio; Butler, Harry; Turner, Joanna; Wainwright, Lisa

    2015-01-01

    The International Commission on Non-Ionizing Radiation Protection (ICNIRP) has established guidelines for exposure to ultraviolet radiation in outdoor occupational settings. Spectrally weighted ICNIRP ultraviolet exposures received by the skin or eye in an 8 h period are limited to 30 J m(-2). In this study, the time required to reach the ICNIRP exposure limit was measured daily in 10 min intervals upon a horizontal plane at a subtropical Australian latitude over a full year and compared with the effective Vitamin D dose received to one-quarter of the available skin surface area for all six Fitzpatrick skin types. The comparison of measured solar ultraviolet exposures for the full range of sky conditions in the 2009 measurement period, including a major September continental dust event, show a clear relationship between the weighted ICNIRP and the effective vitamin D dose. Our results show that the horizontal plane ICNIRP ultraviolet exposure may be used under these conditions to provide minimum guidelines for the healthy moderation of vitamin D, scalable to each of the six Fitzpatrick skin types. © 2014 The American Society of Photobiology.

  20. Limited scleroderma and early detection of visceral changes

    International Nuclear Information System (INIS)

    Kalyuzhnaya, L.D.; Potsibina, V.V.; Stychinskaya, L.P.; Turik, N.V.

    1989-01-01

    The state of liver, kidneys, osteoarticular apparatus at the early stages of development of limited scleroderma and with the exclusion of visceral changes on the basis of clinical-laboratory studies is investigated. 11 patients with scleroderma in the age of 7-18 years were examined. Osteoscintigraphy with 99m TC-phosphone and dynamic scintigraphy of kidneys without additional introduction of RF, and hepatocholecyctoscintigraphy with 99m tc-HIPA of the patients were realized. The conclusion is made that radionuclide investigation methods permit to reveal various visceral changes, which are not recognizable by clinical methods

  1. Methodologies for the practical determination and use of method detection limits

    International Nuclear Information System (INIS)

    Rucker, T.L.

    1995-01-01

    Method detection limits have often been misunderstood and misused. The basic definitions developed by Lloyd Currie and others have been combined with assumptions that are inappropriate for many types of radiochemical analyses. A partical way for determining detection limits based on Currie's basic definition is presented that removes the reliance on assumptions and that accounts for the total measurement uncertainty. Examples of proper and improper use of detection limits are also presented, including detection limits reported by commercial software for gamma spectroscopy and neutron activation analyses. (author) 6 refs.; 2 figs

  2. Practical low dose limits for passive personal dosemeters and the implications for uncertainties close to the limit of detection

    International Nuclear Information System (INIS)

    Gilvin, P. J.; Perks, C. A.

    2011-01-01

    Recent years have seen the increasing use of passive dosemeters that have high sensitivities and, in laboratory conditions, detection limits of <10 μSv. However, in real operational use the detection limits will be markedly higher, because a large fraction of the accrued dose will be due to natural background, and this must be subtracted in order to obtain the desired occupational dose. No matter how well known the natural background is, the measurement uncertainty on doses of a few tens of microsieverts will be large. Individual monitoring services need to recognise this and manage the expectations of their clients by providing sufficient information. (authors)

  3. Currie detection limits in gamma-ray spectroscopy

    International Nuclear Information System (INIS)

    Geer, L.-E. de

    2004-01-01

    Currie Hypothesis testing is applied to gamma-ray spectral data, where an optimum part of the peak is used and the background is considered well known from nearby channels. With this, the risk of making Type I errors is about 100 times lower than commonly assumed. A programme, PeakMaker, produces random peaks with given characteristics on the screen and calculations are done to facilitate a full use of Poisson statistics in spectrum analyses. Short technical note summary: The Currie decision limit concept applied to spectral data is reinterpreted, which gives better consistency between the selected error risk and the observed error rates. A PeakMaker program is described and the few count problem is analyzed

  4. Current limitations and challenges in nanowaste detection, characterisation and monitoring.

    Science.gov (United States)

    Part, Florian; Zecha, Gudrun; Causon, Tim; Sinner, Eva-Kathrin; Huber-Humer, Marion

    2015-09-01

    Engineered nanomaterials (ENMs) are already extensively used in diverse consumer products. Along the life cycle of a nano-enabled product, ENMs can be released and subsequently accumulate in the environment. Material flow models also indicate that a variety of ENMs may accumulate in waste streams. Therefore, a new type of waste, so-called nanowaste, is generated when end-of-life ENMs and nano-enabled products are disposed of. In terms of the precautionary principle, environmental monitoring of end-of-life ENMs is crucial to allow assessment of the potential impact of nanowaste on our ecosystem. Trace analysis and quantification of nanoparticulate species is very challenging because of the variety of ENM types that are used in products and low concentrations of nanowaste expected in complex environmental media. In the framework of this paper, challenges in nanowaste characterisation and appropriate analytical techniques which can be applied to nanowaste analysis are summarised. Recent case studies focussing on the characterisation of ENMs in waste streams are discussed. Most studies aim to investigate the fate of nanowaste during incineration, particularly considering aerosol measurements; whereas, detailed studies focusing on the potential release of nanowaste during waste recycling processes are currently not available. In terms of suitable analytical methods, separation techniques coupled to spectrometry-based methods are promising tools to detect nanowaste and determine particle size distribution in liquid waste samples. Standardised leaching protocols can be applied to generate soluble fractions stemming from solid wastes, while micro- and ultrafiltration can be used to enrich nanoparticulate species. Imaging techniques combined with X-ray-based methods are powerful tools for determining particle size, morphology and screening elemental composition. However, quantification of nanowaste is currently hampered due to the problem to differentiate engineered from

  5. Search times and probability of detection in time-limited search

    Science.gov (United States)

    Wilson, David; Devitt, Nicole; Maurer, Tana

    2005-05-01

    When modeling the search and target acquisition process, probability of detection as a function of time is important to war games and physical entity simulations. Recent US Army RDECOM CERDEC Night Vision and Electronics Sensor Directorate modeling of search and detection has focused on time-limited search. Developing the relationship between detection probability and time of search as a differential equation is explored. One of the parameters in the current formula for probability of detection in time-limited search corresponds to the mean time to detect in time-unlimited search. However, the mean time to detect in time-limited search is shorter than the mean time to detect in time-unlimited search and the relationship between them is a mathematical relationship between these two mean times. This simple relationship is derived.

  6. Calculating exclusion limits for weakly interacting massive particle direct detection experiments without background subtraction

    International Nuclear Information System (INIS)

    Green, Anne M.

    2002-01-01

    Competitive limits on the weakly interacting massive particle (WIMP) spin-independent scattering cross section are currently being produced by 76 Ge detectors originally designed to search for neutrinoless double beta decay, such as the Heidelberg-Moscow and IGEX experiments. In the absence of background subtraction, limits on the WIMP interaction cross section are set by calculating the upper confidence limit on the theoretical event rate, given the observed event rate. The standard analysis technique involves calculating the 90% upper confidence limit on the number of events in each bin, and excluding any set of parameters (WIMP mass and cross section) which produces a theoretical event rate for any bin which exceeds the 90% upper confidence limit on the event rate for that bin. We show that, if there is more than one energy bin, this produces exclusion limits that are actually at a lower degree of confidence than 90%, and are hence erroneously tight. We formulate criteria which produce true 90% confidence exclusion limits in these circumstances, including calculating the individual bin confidence limit for which the overall probability that no bins exceed this confidence limit is 90% and calculating the 90% minimum confidence limit on the number of bins which exceed their individual bin 90% confidence limits. We then compare the limits on the WIMP cross section produced by these criteria with those found using the standard technique, using data from the Heidelberg-Moscow and IGEX experiments

  7. Accounting for pore water pressure and confined aquifers in assessing the stability of slopes: a Limit Equilibrium analysis carried out through the Minimum Lithostatic Deviation method

    Science.gov (United States)

    Ausilia Paparo, Maria; Tinti, Stefano

    2015-04-01

    The model we introduce is an implementation of the Minimum Lithostatic Deviation (MLD) method, developed by Tinti and Manucci (Tinti and Manucci 2006; 2008), that makes use of the limit equilibrium (LE) theory to estimate the stability of a slope. The main purpose here is to analyse the role of a confined aquifer on the value of the Safety Factor (F), the parameter that in the LE is used to determine if a slope is stable or unstable. The classical LE methods treat unconfined aquifers by including the water pore pressure in the Mohr-Coulomb failure formula: since the water decreases the friction shear strength, the soil above the sliding surface turns out to be more prone to instability. In case of a confined aquifer, however, due to a presence of impermeable layers, the water is not free to flow into the matrix of the overlying soil. We consider here the assumption of a permeable soil sliding over an impermeable layer, which is an occurrence that is found in several known landslide cases (e.g. Person, 2008; Strout and Tjeltja, 2008; Morgan et al., 2010 for offshore slides; and Palladino and Peck, 1972; Miller and Sias, 1998; Jiao et al. 2005; Paparo et al., 2013 for slopes in proximity of artificial or natural water basins) where clay beds form the potential sliding surface: the water, confined below, pushes along these layers and acts on the sliding body as an external bottom load. We modify the MLD method equations in order to take into account the load due to a confined aquifer and apply the new model to the Vajont case, where many have hypothesised the contribution of a confined aquifer to the failure. Our calculations show that the rain load i) infiltrating directly into the soil body and ii) penetrating into the confined aquifer below the clay layers, in addition with the lowering of the reservoir level, were key factors of destabilization of the Mt Toc flank and caused the disastrous landslide.

  8. Determination of detection limits for a VPD ICPMS method of analysis

    International Nuclear Information System (INIS)

    Badard, M.; Veillerot, M.

    2007-01-01

    This training course report presents the different methods of detection and quantifying of metallic impurities in semiconductors. One of the most precise technique is the collection of metal impurities by vapor phase decomposition (VPD) followed by their analysis by ICPMS (inductively coupled plasma mass spectrometry). The study shows the importance of detection limits in the domain of chemical analysis and the way to determine them for the ICPMS analysis. The results found on detection limits are excellent. Even if the detection limits reached with ICPMS performed after manual or automatic VPD are much higher than detection limits of ICPMS alone, this method remains one of the most sensible for ultra-traces analysis. (J.S.)

  9. Improvement in Limit of Detection of Enzymatic Biogas Sensor Utilizing Chromatography Paper for Breath Analysis.

    Science.gov (United States)

    Motooka, Masanobu; Uno, Shigeyasu

    2018-02-02

    Breath analysis is considered to be an effective method for point-of-care diagnosis due to its noninvasiveness, quickness and simplicity. Gas sensors for breath analysis require detection of low-concentration substances. In this paper, we propose that reduction of the background current improves the limit of detection of enzymatic biogas sensors utilizing chromatography paper. After clarifying the cause of the background current, we reduced the background current by improving the fabrication process of the sensors utilizing paper. Finally, we evaluated the limit of detection of the sensor with the sample vapor of ethanol gas. The experiment showed about a 50% reduction of the limit of detection compared to previously-reported sensor. This result presents the possibility of the sensor being applied in diagnosis, such as for diabetes, by further lowering the limit of detection.

  10. Assessment of detection limits of fiber-optic distributed temperature sensing for detection of illicit connections

    NARCIS (Netherlands)

    Nienhuis, J.; De Haan, C.; Langeveld, J.G.; Klootwijk, M.; Clemens, F.H.L.R.

    2012-01-01

    Distributed Temperature Sensing (DTS) with fiber-optic cables is a powerful tool to detect illicit connections in storm sewer systems. High frequency temperature measurements along the in-sewer cable create a detailed representation of temperature anomalies due to illicit discharges. The detection

  11. Impact of sensor detection limits on protecting water distribution systems from contamination events

    International Nuclear Information System (INIS)

    McKenna, Sean Andrew; Hart, David Blaine; Yarrington, Lane

    2006-01-01

    Real-time water quality sensors are becoming commonplace in water distribution systems. However, field deployable, contaminant-specific sensors are still in the development stage. As development proceeds, the necessary operating parameters of these sensors must be determined to protect consumers from accidental and malevolent contamination events. This objective can be quantified in several different ways including minimization of: the time necessary to detect a contamination event, the population exposed to contaminated water, the extent of the contamination within the network, and others. We examine the ability of a sensor set to meet these objectives as a function of both the detection limit of the sensors and the number of sensors in the network. A moderately sized distribution network is used as an example and different sized sets of randomly placed sensors are considered. For each combination of a certain number of sensors and a detection limit, the mean values of the different objectives across multiple random sensor placements are calculated. The tradeoff between the necessary detection limit in a sensor and the number of sensors is evaluated. Results show that for the example problem examined here, a sensor detection limit of 0.01 of the average source concentration is adequate for maximum protection. Detection of events is dependent on the detection limit of the sensors, but for those events that are detected, the values of the performance measures are not a function of the sensor detection limit. The results of replacing a single sensor in a network with a sensor having a much lower detection limit show that while this replacement can improve results, the majority of the additional events detected had performance measures of relatively low consequence.

  12. Reliability, standard error, and minimum detectable change of clinical pressure pain threshold testing in people with and without acute neck pain.

    Science.gov (United States)

    Walton, David M; Macdermid, Joy C; Nielson, Warren; Teasell, Robert W; Chiasson, Marco; Brown, Lauren

    2011-09-01

    Clinical measurement. To evaluate the intrarater, interrater, and test-retest reliability of an accessible digital algometer, and to determine the minimum detectable change in normal healthy individuals and a clinical population with neck pain. Pressure pain threshold testing may be a valuable assessment and prognostic indicator for people with neck pain. To date, most of this research has been completed using algometers that are too resource intensive for routine clinical use. Novice raters (physiotherapy students or clinical physiotherapists) were trained to perform algometry testing over 2 clinically relevant sites: the angle of the upper trapezius and the belly of the tibialis anterior. A convenience sample of normal healthy individuals and a clinical sample of people with neck pain were tested by 2 different raters (all participants) and on 2 different days (healthy participants only). Intraclass correlation coefficient (ICC), standard error of measurement, and minimum detectable change were calculated. A total of 60 healthy volunteers and 40 people with neck pain were recruited. Intrarater reliability was almost perfect (ICC = 0.94-0.97), interrater reliability was substantial to near perfect (ICC = 0.79-0.90), and test-retest reliability was substantial (ICC = 0.76-0.79). Smaller change was detectable in the trapezius compared to the tibialis anterior. This study provides evidence that novice raters can perform digital algometry with adequate reliability for research and clinical use in people with and without neck pain.

  13. Cs2AgBiBr6 single-crystal X-ray detectors with a low detection limit

    Science.gov (United States)

    Pan, Weicheng; Wu, Haodi; Luo, Jiajun; Deng, Zhenzhou; Ge, Cong; Chen, Chao; Jiang, Xiaowei; Yin, Wan-Jian; Niu, Guangda; Zhu, Lujun; Yin, Lixiao; Zhou, Ying; Xie, Qingguo; Ke, Xiaoxing; Sui, Manling; Tang, Jiang

    2017-11-01

    Sensitive X-ray detection is crucial for medical diagnosis, industrial inspection and scientific research. The recently described hybrid lead halide perovskites have demonstrated low-cost fabrication and outstanding performance for direct X-ray detection, but they all contain toxic Pb in a soluble form. Here, we report sensitive X-ray detectors using solution-processed double perovskite Cs2AgBiBr6 single crystals. Through thermal annealing and surface treatment, we largely eliminate Ag+/Bi3+ disordering and improve the crystal resistivity, resulting in a detector with a minimum detectable dose rate as low as 59.7 nGyair s-1, comparable to the latest record of 0.036 μGyair s-1 using CH3NH3PbBr3 single crystals. Suppressed ion migration in Cs2AgBiBr6 permits relatively large external bias, guaranteeing efficient charge collection without a substantial increase in noise current and thus enabling the low detection limit.

  14. Working with Detection Limits in X-Ray and Nuclear Spectrometry

    International Nuclear Information System (INIS)

    Van Espen, P.

    2003-01-01

    Full Text: Detection limits are important in many measurement procedures. Especially in analytical work we often need to take a decision about the presence or absence of a compound, or we need to guarantee that or instrument can detect the compound. Especially in regulatory work the concept of detection limits plays a crucial role. Data acquisition in x-ray and gamma-ray spectrometry is done by counting events for a preset time; hence the fluctuations in the observed spectra are governed by Poisson (counting) statistics. This makes the calculation of detection limits in principle very easy. However it is observed that there exists a great deal of confusion concerning the definition(s) and especially concerning the practical calculation and reporting of detection limits. In this contribution a simple but rigorous treatment of the concept of detection limits will be given, emphasizing on aspects such as a-priori and a-posterior i limits and on the effect of sample blank and instrumental blank in the calculation of the true detection limit. The problem of near zero background as observed in e.g. total reflection x-ray fluorescence analysis (T-XRF) and some low level counting applications will also be discussed. In this case Poisson statistics might not be applicable, affecting the decision limits with respect to the presence of absence of a signal. Finally handling data sets that contain detection limit values next to normal measured values, the so called problem of missing data will be discussed. Some suggestions to deal with this frequently occurring situation will be given

  15. Improved detection limits for phthalates by selective solid-phase micro-extraction

    KAUST Repository

    Zia, Asif I.; Afsarimanesh, Nasrin; Xie, Li; Nag, Anindya; Al-Bahadly, I. H.; Yu, P. L.; Kosel, Jü rgen

    2016-01-01

    Presented research reports on an improved method and enhanced limits of detection for phthalates; a hazardous additive used in the production of plastics by solid-phase micro-extraction (SPME) polymer in comparison to molecularly imprinted solid

  16. Limited interlaboratory comparison of Schmallenberg virus antibody detection in serum samples

    DEFF Research Database (Denmark)

    van der Poel, W. H. M.; Cay, B.; Zientara, S.

    2014-01-01

    Eight veterinary institutes in seven different countries in Europe participated in a limited interlaboratory comparison trial to evaluate laboratory performances of Schmallenberg virus (SBV) antibody detection in serum. Seven different sheep sera and three different cattle sera were circulated, a...

  17. Censoring: a new approach for detection limits in total-reflection X-ray fluorescence

    International Nuclear Information System (INIS)

    Pajek, M.; Kubala-Kukus, A.; Braziewicz, J.

    2004-01-01

    It is shown that the detection limits in the total-reflection X-ray fluorescence (TXRF), which restrict quantification of very low concentrations of trace elements in the samples, can be accounted for using the statistical concept of censoring. We demonstrate that the incomplete TXRF measurements containing the so-called 'nondetects', i.e. the non-measured concentrations falling below the detection limits and represented by the estimated detection limit values, can be viewed as the left random-censored data, which can be further analyzed using the Kaplan-Meier (KM) method correcting for nondetects. Within this approach, which uses the Kaplan-Meier product-limit estimator to obtain the cumulative distribution function corrected for the nondetects, the mean value and median of the detection limit censored concentrations can be estimated in a non-parametric way. The Monte Carlo simulations performed show that the Kaplan-Meier approach yields highly accurate estimates for the mean and median concentrations, being within a few percent with respect to the simulated, uncensored data. This means that the uncertainties of KM estimated mean value and median are limited in fact only by the number of studied samples and not by the applied correction procedure for nondetects itself. On the other hand, it is observed that, in case when the concentration of a given element is not measured in all the samples, simple approaches to estimate a mean concentration value from the data yield erroneous, systematically biased results. The discussed random-left censoring approach was applied to analyze the TXRF detection-limit-censored concentration measurements of trace elements in biomedical samples. We emphasize that the Kaplan-Meier approach allows one to estimate the mean concentrations being substantially below the mean level of detection limits. Consequently, this approach gives a new access to lower the effective detection limits for TXRF method, which is of prime interest for

  18. Accuracy and detection limits for bioassay measurements in radiation protection. Statistical considerations

    International Nuclear Information System (INIS)

    Brodsky, A.

    1986-04-01

    This report provides statistical concepts and formulas for defining minimum detectable amount (MDA), bias and precision of sample analytical measurements of radioactivity for radiobioassay purposes. The defined statistical quantities and accuracy criteria were developed for use in standard performance criteria for radiobioassay, but are also useful in intralaboratory quality assurance programs. This report also includes a literature review and analysis of accuracy needs and accuracy recommendations of national and international scientific organizations for radiation or radioactivity measurements used for radiation protection purposes. Computer programs are also included for calculating the probabilities of passing or failing multiple analytical tests for different acceptable ranges of bias and precision

  19. Visualizing the Limits of Low Vision in Detecting Natural Image Features

    NARCIS (Netherlands)

    Hogervorst, M.A.; Damme, W.J.M. van

    2008-01-01

    Purpose. The purpose of our study was to develop a tool to visualize the limitations posed by visual impairments in detecting small and low-contrast elements in natural images. This visualization tool incorporates existing models of several aspects of visual perception, such as the band-limited

  20. Investigation of a gamma sensitive Ge-detector with Marinelligeometry. Determination of the detection limits

    International Nuclear Information System (INIS)

    Moricz, P.

    1984-01-01

    Different Marinelli geometries have been compared with a 180 ml standard plastic breaker geometry as a reference. The results show that the Marinelli geometries are the best. E.g. the detection limit with a Marinelli geometry of 0.5 l is only half compared with the limit when the standard geometry is used. (Edv)

  1. Decreasing of the detection limit for gamma-ray Spectrometry with the influence of sample treatment

    International Nuclear Information System (INIS)

    Karami, M.; Sadighzadeh, A.; Asgharizadeh, F.; Sardari, D.; Tavassoli, A.; Arbabi, A.; Hochaghani, O.

    2009-01-01

    Full text: In this study the ash method has been applied for environmental sample treatment in order to decrease of the detection limit in gamma-ray spectrometry for low level radioactivity measurements. Detection limit in gamma ray spectrometry is the smallest expectation value of the net counting rate that can be detected on given probabilities. The environmental test samples have been changed into ash using a suitable oven. The heating were made under controlled temperature to avoid the escape of some radionuclides such as radiocaesium. The ash samples were measured by high resolution gamma-ray spectrometry system. (author)

  2. Simulated minimum detectable activity concentration (MDAC) for a real-time UAV airborne radioactivity monitoring system with HPGe and LaBr_3 detectors

    International Nuclear Information System (INIS)

    Tang, Xiao-Bin; Meng, Jia; Wang, Peng; Cao, Ye; Huang, Xi; Wen, Liang-Sheng; Chen, Da

    2016-01-01

    An automatic real-time UAV airborne radioactivity monitoring system with high-purity germanium (HPGe) and lanthanum bromide (LaBr_3) detectors (NH-UAV) was developed to precisely obtain small-scope nuclide information in major nuclear accidents. The specific minimum detectable activity concentration (MDAC) calculation method for NH-UAV in the atmospheric environment was deduced in this study for a priori evaluation and quantification of the suitability of NH-UAV in the Fukushima nuclear accident, where the MDAC values of this new equipment were calculated based on Monte Carlo simulation. The effects of radioactive source term size and activity concentration on the MDAC values were analyzed to assess the detection performance of NH-UAV in more realistic environments. Finally, the MDAC values were calculated at different shielding thicknesses of the HPGe detector to improve the detection capabilities of the HPGe detector, and the relationship between the MDAC and the acquisition time of the system was deduced. The MDAC calculation method and data results in this study may be used as a reference for in-situ radioactivity measurement of NH-UAV. - Highlights: • A real-time UAV airborne radioactivity monitoring system (NH-UAV) was developed. • The efficiency calculations and MDAC values are given. • NH-UAV is able to monitor major nuclear accidents, such as the Fukushima accident. • The source term size can influence the detection sensitivity of the system. • The HPGe detector possesses measurement thresholds on activity concentration.

  3. Unequivocal detection of ozone recovery in the Antarctic Ozone Hole through significant increases in atmospheric layers with minimum ozone

    Science.gov (United States)

    de Laat, Jos; van Weele, Michiel; van der A, Ronald

    2015-04-01

    An important new landmark in present day ozone research is presented through MLS satellite observations of significant ozone increases during the ozone hole season that are attributed unequivocally to declining ozone depleting substances. For many decades the Antarctic ozone hole has been the prime example of both the detrimental effects of human activities on our environment as well as how to construct effective and successful environmental policies. Nowadays atmospheric concentrations of ozone depleting substances are on the decline and first signs of recovery of stratospheric ozone and ozone in the Antarctic ozone hole have been observed. The claimed detection of significant recovery, however, is still subject of debate. In this talk we will discuss first current uncertainties in the assessment of ozone recovery in the Antarctic ozone hole by using multi-variate regression methods, and, secondly present an alternative approach to identify ozone hole recovery unequivocally. Even though multi-variate regression methods help to reduce uncertainties in estimates of ozone recovery, great care has to be taken in their application due to the existence of uncertainties and degrees of freedom in the choice of independent variables. We show that taking all uncertainties into account in the regressions the formal recovery of ozone in the Antarctic ozone hole cannot be established yet, though is likely before the end of the decade (before 2020). Rather than focusing on time and area averages of total ozone columns or ozone profiles, we argue that the time evolution of the probability distribution of vertically resolved ozone in the Antarctic ozone hole contains a better fingerprint for the detection of ozone recovery in the Antarctic ozone hole. The advantages of this method over more tradition methods of trend analyses based on spatio-temporal average ozone are discussed. The 10-year record of MLS satellite measurements of ozone in the Antarctic ozone hole shows a

  4. Censoring approach to the detection limits in X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Pajek, M.; Kubala-Kukus, A.

    2004-01-01

    We demonstrate that the effect of detection limits in the X-ray fluorescence analysis (XRF), which limits the determination of very low concentrations of trace elements and results in appearance of the so-called 'nondetects', can be accounted for using the statistical concept of censoring. More precisely, the results of such measurements can be viewed as the left random censored data, which can further be analyzed using the Kaplan-Meier method correcting the data for the presence of nondetects. Using this approach, the results of measured, detection limit censored concentrations can be interpreted in a nonparametric manner including the correction for the nondetects, i.e. the measurements in which the concentrations were found to be below the actual detection limits. Moreover, using the Monte Carlo simulation technique we show that by using the Kaplan-Meier approach the corrected mean concentrations for a population of the samples can be estimated within a few percent uncertainties with respect of the simulated, uncensored data. This practically means that the final uncertainties of estimated mean values are limited in fact by the number of studied samples and not by the correction procedure itself. The discussed random-left censoring approach was applied to analyze the XRF detection-limit-censored concentration measurements of trace elements in biomedical samples

  5. Prediction of the limit of detection of an optical resonant reflection biosensor.

    Science.gov (United States)

    Hong, Jongcheol; Kim, Kyung-Hyun; Shin, Jae-Heon; Huh, Chul; Sung, Gun Yong

    2007-07-09

    A prediction of the limit of detection of an optical resonant reflection biosensor is presented. An optical resonant reflection biosensor using a guided-mode resonance filter is one of the most promising label-free optical immunosensors due to a sharp reflectance peak and a high sensitivity to the changes of optical path length. We have simulated this type of biosensor using rigorous coupled wave theory to calculate the limit of detection of the thickness of the target protein layer. Theoretically, our biosensor has an estimated ability to detect thickness change approximately the size of typical antigen proteins. We have also investigated the effects of the absorption and divergence of the incident light on the detection ability of the biosensor.

  6. Theoretical detection limit of PIXE analysis using 20 MeV proton beams

    Science.gov (United States)

    Ishii, Keizo; Hitomi, Keitaro

    2018-02-01

    Particle-induced X-ray emission (PIXE) analysis is usually performed using proton beams with energies in the range 2∼3 MeV because at these energies, the detection limit is low. The detection limit of PIXE analysis depends on the X-ray production cross-section, the continuous background of the PIXE spectrum and the experimental parameters such as the beam currents and the solid angle and detector efficiency of X-ray detector. Though the continuous background increases as the projectile energy increases, the cross-section of the X-ray increases as well. Therefore, the detection limit of high energy proton PIXE is not expected to increase significantly. We calculated the cross sections of continuous X-rays produced in several bremsstrahlung processes and estimated the detection limit of a 20 MeV proton PIXE analysis by modelling the Compton tail of the γ-rays produced in the nuclear reactions, and the escape effect on the secondary electron bremsstrahlung. We found that the Compton tail does not affect the detection limit when a thin X-ray detector is used, but the secondary electron bremsstrahlung escape effect does have an impact. We also confirmed that the detection limit of the PIXE analysis, when used with 4 μm polyethylene backing film and an integrated beam current of 1 μC, is 0.4∼2.0 ppm for proton energies in the range 10∼30 MeV and elements with Z = 16-90. This result demonstrates the usefulness of several 10 MeV cyclotrons for performing PIXE analysis. Cyclotrons with these properties are currently installed in positron emission tomography (PET) centers.

  7. Application of Statistical Methods to Activation Analytical Results near the Limit of Detection

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Wanscher, B.

    1978-01-01

    Reporting actual numbers instead of upper limits for analytical results at or below the detection limit may produce reliable data when these numbers are subjected to appropriate statistical processing. Particularly in radiometric methods, such as activation analysis, where individual standard...... deviations of analytical results may be estimated, improved discrimination may be based on the Analysis of Precision. Actual experimental results from a study of the concentrations of arsenic in human skin demonstrate the power of this principle....

  8. 40 CFR Figure C-4 to Subpart C of... - Illustration of the Minimum Limits for Correlation Coefficient for PM2.5 and PM10−2.5 Class II...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Illustration of the Minimum Limits for Correlation Coefficient for PM2.5 and PM10â2.5 Class II and III Methods C Figure C-4 to Subpart C of Part 53... Methods and Reference Methods Pt. 53, Subpt. C, Fig. C-4 Figure C-4 to Subpart C of Part 53—Illustration...

  9. The detection limits of antimicrobial agents in cow's milk by a simple Yoghurt Culture Test.

    Science.gov (United States)

    Mohsenzadeh, M; Bahrainipour, A

    2008-09-15

    The aim of this study was to study performance of Yoghurt Culture Test (YCT) in the detection of antimicrobial residues in milk. For this purpose, the sensitivity of YCT for 15 antibiotics were determined. For each drug, 8 concentrations were tested. The detection limits of YCT at 2.5 h and 4 h incubation were determined (microg kg(-1)): 15 and 37.5, penicillin G; 4 and 5, ampicillin; 5 and 7.5, amoxycillin; 100 and 200, cephalexin; 80 and 100, cefazoline; 100 and 200, oxytetracycline; 500 and 100, chlortetracycline; 100 and 200, tetracycline; 150 and 200, doxycycline; 200 and 400, sulphadimidine; 500 and 1000, gentamycin; 1000 and 1500, spectinomycin; 400 and 500, erythromycin; 50 and 100, tylosin; 5000 and 10000, chloramphenicol. The YCT detection limits at 2.5 h incubation for ampicillin, cephalexin, tetracycline, oxytetracycline and tylosin are similar to those obtained as Maximum Residue Limit (MRL) according to Regulation 2377/90 EEC as set out by the European Union. In addition the detection limits of YCT for some antibiotics were lower than some of microbial inhibitor test.

  10. ROBUST ESTIMATION OF MEAN AND VARIANCE USING ENVIRONMENTAL DATA SETS WITH BELOW DETECTION LIMIT OBSERVATIONS

    Science.gov (United States)

    Scientists, especially environmental scientists often encounter trace level concentrations that are typically reported as less than a certain limit of detection, L. Type 1, left-censored data arise when certain low values lying below L are ignored or unknown as they cannot be mea...

  11. Detection limits of antimicrobials in ewe milk by delvotest photometric measurements.

    Science.gov (United States)

    Althaus, R L; Torres, A; Montero, A; Balasch, S; Molina, M P

    2003-02-01

    The Delvotest method detection limits per manufacturer's instructions at a fixed reading time of 3 h for 24 antimicrobial agents were determined in ewe milk by photometric measurement. For each drug, eight concentrations were tested on 20 ewe milk samples from individual ewes. Detection limits, determined by means of logistic regression models, were (microg/kg): 3, amoxycillin; 2, ampicillin; 18, cloxacillin; 1, penicillin "G"; 34, cefadroxil; 430, cephalosporin "C"; 40, cephalexin; 20, cefoperazone; 33, Ceftiofur; 18, cefuroxime; 6100, streptomycin; 1200, gentamycin; 2600, neomycin; 830, erythromycin; 100, tylosin; 180, doxycycline; 320, oxytetracycline; 590, tetracycline; 88, sulfadiazine; 44, sulfamethoxazole; 140, sulfametoxypyridazine; 48, sulfaquinoxaline; 12,000, chloramphenicol; and 290, trimethoprim. Whereas the beta-lactam antibiotics, sulphonamides, and tylosin were detected by Delvotest method at levels equal to those of maximum residue limits, its sensitivity needs to be enhanced to detect aminoglycosides, tetracyclines, streptomycin, chloramphenicol, and trimethoprim residues in ewe milk or to develop an integrated residue detection system for ewe milk with different sensitive microorganisms for each group of antiinfectious agents.

  12. Investigation on feasibility and detection limits for determination of coating film thickness by neutron activation analysis

    International Nuclear Information System (INIS)

    Yao Maoying; Xu Jiayun; Zhang Dida; Yang Zunyong; Yao Zhenqiang; Wang Mingqiu; Gao Dangzhong

    2010-01-01

    A method for the determination of coating film thickness by neutron activation was proposed in this paper. After Au, Al and Cu et al.films were activated with a Am-Be neutron source, the characteristic γ-rays emitted by the activated nuclides in the films were counted with a HPGe γ spectrometer. The detection limits of film thickness by using a nuclear reactor neutron source were deduced on the basis of the γ-ray counts and the Monte-Carlo simulated detection efficiencies. The possible detection limits are typically 4-5 orders of magnitude better than those by fluorescent X-ray method, which is currently widely used to determine coating film thickness. (authors)

  13. Planejamento agregado da produção ótimo com limite mínimo de estoque influenciado pelas incertezas de demanda Optimal aggregate production planning with minimum inventory limit affected by demand uncertainties

    Directory of Open Access Journals (Sweden)

    Oscar S. Silva Filho

    1995-04-01

    probability distribution function assumed as gaussian. Thus the problem studied here is a stochastic planning one with probabilistic constraint at the inventory level variable. It is shown that it is possible to obtain, by means of appropriate transformations, a deterministic equivalent formulation, for which an open-loop solution to stochastic problems can be generated, using any applicable mathematical programming algorithm. It is also shown that the uncertainties concerning demand fluctuation are explicitly presented in the deterministic formulation through a constraint function that represents the minimum inventory level limit or safety stock. This function is essentially concave and increases during time and depends on the variance of inventory level and probabilistic degree supply by the user to the inventory constraint. To illustrate the theoretical developments, a simple example of a single product system is proposed and solved by dynamic programming. The open- loop solution (i.e. approximate solution from an equivalent problem is compared with the true solution obtained directly from the stochastic problem via stochastic dynamic programming.

  14. In vitro bioassays for detecting dioxin-like activity--application potentials and limits of detection, a review.

    Science.gov (United States)

    Eichbaum, Kathrin; Brinkmann, Markus; Buchinger, Sebastian; Reifferscheid, Georg; Hecker, Markus; Giesy, John P; Engwall, Magnus; van Bavel, Bert; Hollert, Henner

    2014-07-15

    Use of in vitro assays as screening tool to characterize contamination of a variety of environmental matrices has become an increasingly popular and powerful toolbox in the field of environmental toxicology. While bioassays cannot entirely substitute analytical methods such as gas chromatography-mass spectrometry (GC-MS), the increasing improvement of cell lines and standardization of bioassay procedures enhance their utility as bioanalytical pre-screening tests prior to more targeted chemical analytical investigations. Dioxin-receptor-based assays provide a holistic characterization of exposure to dioxin-like compounds (DLCs) by integrating their overall toxic potential, including potentials of unknown DLCs not detectable via e.g. GC-MS. Hence, they provide important additional information with respect to environmental risk assessment of DLCs. This review summarizes different in vitro bioassay applications for detection of DLCs and considers the comparability of bioassay and chemical analytically derived toxicity equivalents (TEQs) of different approaches and various matrices. These range from complex samples such as sediments through single reference to compound mixtures. A summary of bioassay derived detection limits (LODs) showed a number of current bioassays to be equally sensitive as chemical methodologies, but moreover revealed that most of the bioanalytical studies conducted to date did not report their LODs, which represents a limitation with regard to low potency samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. High-Field Quench Behavior and Protection of $Bi_2 Sr_2 Ca Cu_2 O_x$ Coils: Minimum and Maximum Quench Detection Voltages

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Tengming [Fermilab; Ye, Liyang [NCSU, Raleigh; Turrioni, Daniele [Fermilab; Li, Pei [Fermilab

    2015-01-01

    Small insert coils have been built using a multifilamentary Bi2Sr2CaCu2Ox round wire, and characterized in background fields to explore the quench behaviors and limits of Bi2Sr2CaCu2Ox superconducting magnets, with an emphasis on assessing the impact of slow normal zone propagation on quench detection. Using heaters of various lengths to initiate a small normal zone, a coil was quenched safely more than 70 times without degradation, with the maximum coil temperature reaching 280 K. Coils withstood a resistive voltage of tens of mV for seconds without quenching, showing the high stability of these coils and suggesting that the quench detection voltage shall be greater than 50 mV to not to falsely trigger protection. The hot spot temperature for the resistive voltage of the normal zone to reach 100 mV increases from ~40 K to ~80 K with increasing the operating wire current density Jo from 89 A/mm2 to 354 A/mm2 whereas for the voltage to reach 1 V, it increases from ~60 K to ~140 K, showing the increasing negative impact of slow normal zone propagation on quench detection with increasing Jo and the need to limit the quench detection voltage to < 1 V. These measurements, coupled with an analytical quench model, were used to access the impact of the maximum allowable voltage and temperature upon quench detection on the quench protection, assuming to limit the hot spot temperature to <300 K.

  16. Gold nanoparticle-based low limit of detection Love wave biosensor for carcinoembryonic antigens.

    Science.gov (United States)

    Li, Shuangming; Wan, Ying; Su, Yan; Fan, Chunhai; Bhethanabotla, Venkat R

    2017-09-15

    In this work, a Love wave biosensing platform is described for detecting cancer-related biomarker carcinoembryonic antigen (CEA). An ST 90°-X quartz Love wave device with a layer of SiO 2 waveguide was combined with gold nanoparticles (Au NPs) to amplify the mass loading effect of the acoustic wave sensor to achieve a limit of detection of 37pg/mL. The strategy involves modifying the Au NPs with anti-CEA antibody conjugates to form nanoprobes in a sandwich immunoassay. The unamplified detection limit of the Love wave biosensor is 9.4ng/mL. This 2-3 order of magnitude reduction in the limit of detection brings the SAW platform into the range useful for clinical diagnosis. Measurement electronics and microfluidics are easily constructed for acoustic wave biosensors, such as the Love wave device described here, allowing for robust platforms for point of care applications for cancer biomarkers in general. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Limits of 2D-TCA in detecting BOLD responses to epileptic activity.

    Science.gov (United States)

    Khatamian, Yasha Borna; Fahoum, Firas; Gotman, Jean

    2011-05-01

    Two-dimensional temporal clustering analysis (2D-TCA) is a relatively new functional MRI (fMRI) based technique that breaks blood oxygen level dependent activity into separate components based on timing and has shown potential for localizing epileptic activity independently of electroencephalography (EEG). 2D-TCA has only been applied to detect epileptic activity in a few studies and its limits in detecting activity of various forms (i.e. activation size, amplitude, and frequency) have not been investigated. This study evaluated 2D-TCA's ability to detect various forms of both simulated epileptic activity and EEG-fMRI activity detected in patients. When applied to simulated data, 2D-TCA consistently detected activity in 6min runs containing 5 spikes/run, 10 spikes/run, and one 5s long event with hemodynamic response function amplitudes of at least 1.5%, 1.25%, and 1% above baseline respectively. When applied to patient data, while detection of interictal spikes was inconsistent, 2D-TCA consistently produced results similar to those obtained by EEG-fMRI when at least 2 prolonged interictal events (a few seconds each) occurred during the run. However, even for such cases it was determined that 2D-TCA can only be used to validate localization by other means or to create hypotheses as to where activity may occur, as it also detects changes not caused by epileptic activity. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Method to Solve the Problem of the Radioactivity Detection in Environmental Samples. Characteristic Limits

    International Nuclear Information System (INIS)

    Gasco, C.; Martinez, M.; Heras, M.

    2009-01-01

    The problem of the detection or when the radioactivity can be considered as higher than the background using different measurement techniques has been the objective of several statistical studies and controversies. The detection limit and the critical limit were studied by Currie in year 1968 and used by radiochemistry laboratories considering different ways of calculation that introduced confusion and not correct implementations. In the last few years, and due to the increasing number of standardization processes on the field of radioactivity and accreditation, several international institutions have chosen to unify the criteria for using common determination of detection limits. The most used methods are those developed by MARLAP and International Standard Organization ISO (Standard-11929). In this report are summarised both standards doing a comparative study and giving some examples of how to apply these limits. In same cases, little differences in the uncertainty calculation have been observed but the final results have been concordant. A deeply study of these standards can be done consulting the web page of the American Labs that developed MARLAP or buying the original ISO standard ISO-11929 recently approved (2009). (Author) 17 refs

  19. A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations

    International Nuclear Information System (INIS)

    Hoop, Bartjan de; Gietema, Hester; Prokop, Mathias; Ginneken, Bram van; Zanen, Pieter; Groenewegen, Gerard

    2009-01-01

    We compared interexamination variability of CT lung nodule volumetry with six currently available semi-automated software packages to determine the minimum change needed to detect the growth of solid lung nodules. We had ethics committee approval. To simulate a follow-up examination with zero growth, we performed two low-dose unenhanced CT scans in 20 patients referred for pulmonary metastases. Between examinations, patients got off and on the table. Volumes of all pulmonary nodules were determined on both examinations using six nodule evaluation software packages. Variability (upper limit of the 95% confidence interval of the Bland-Altman plot) was calculated for nodules for which segmentation was visually rated as adequate. We evaluated 214 nodules (mean diameter 10.9 mm, range 3.3 mm-30.0 mm). Software packages provided adequate segmentation in 71% to 86% of nodules (p < 0.001). In case of adequate segmentation, variability in volumetry between scans ranged from 16.4% to 22.3% for the various software packages. Variability with five to six software packages was significantly less for nodules ≥8 mm in diameter (range 12.9%-17.1%) than for nodules <8 mm (range 18.5%-25.6%). Segmented volumes of each package were compared to each of the other packages. Systematic volume differences were detected in 11/15 comparisons. This hampers comparison of nodule volumes between software packages. (orig.)

  20. Bayesian-statistical decision threshold, detection limit, and confidence interval in nuclear radiation measurement

    International Nuclear Information System (INIS)

    Weise, K.

    1998-01-01

    When a contribution of a particular nuclear radiation is to be detected, for instance, a spectral line of interest for some purpose of radiation protection, and quantities and their uncertainties must be taken into account which, such as influence quantities, cannot be determined by repeated measurements or by counting nuclear radiation events, then conventional statistics of event frequencies is not sufficient for defining the decision threshold, the detection limit, and the limits of a confidence interval. These characteristic limits are therefore redefined on the basis of Bayesian statistics for a wider applicability and in such a way that the usual practice remains as far as possible unaffected. The principle of maximum entropy is applied to establish probability distributions from available information. Quantiles of these distributions are used for defining the characteristic limits. But such a distribution must not be interpreted as a distribution of event frequencies such as the Poisson distribution. It rather expresses the actual state of incomplete knowledge of a physical quantity. The different definitions and interpretations and their quantitative consequences are presented and discussed with two examples. The new approach provides a theoretical basis for the DIN 25482-10 standard presently in preparation for general applications of the characteristic limits. (orig.) [de

  1. Detecting terrestrial nutrient limitation: a global meta-analysis of foliar nutrient concentrations after fertilization

    Directory of Open Access Journals (Sweden)

    Rebecca eOstertag

    2016-03-01

    Full Text Available Examining foliar nutrient concentrations after fertilization provides an alternative method for detecting nutrient limitation of ecosystems, which is logistically simpler to measure than biomass change. We present a meta-analysis of response ratios of foliar nitrogen and phosphorus (RRN, RRP after addition of fertilizer of nitrogen (N, phosphorus (P, or the two elements in combination, in relation to climate, ecosystem type, life form, family, and methodological factors. Results support other meta-analyses using biomass, and demonstrate there is strong evidence for nutrient limitation in natural communities. However, because N fertilization experiments greatly outnumber P fertilization trials, it is difficult to discern the absolute importance of N vs. P vs. co-limitation across ecosystems. Despite these caveats, it is striking that results did not follow conventional wisdom that temperate ecosystems are N-limited and tropical ones are P-limited. In addition, the use of ratios of N-to-P rather than response ratios also are a useful index of nutrient limitation, but due to large overlap in values, there are unlikely to be universal cutoff values for delimiting N vs. P limitation. Differences in RRN and RRP were most significant across ecosystem types, plant families, life forms, and between competitive environments, but not across climatic variables.

  2. Thermal ionization mass spectrometry (TIMS) of actinides: Pushing the limits of accuracy and detection

    Energy Technology Data Exchange (ETDEWEB)

    Buerger, Stefan; Boulyga, Sergei; Cunningham, Alan; Klose, Dilani; Koepf, Andreas; Poths, Jane [Safeguards Analytical Laboratory, International Atomic Energy Agency, Vienna (Austria); Richter, Stephan [Institute for Reference Materials and Measurements, JRC-EU, Geel (Belgium)

    2010-07-01

    New method developments in multi-collector thermal ionization mass spectrometry (MC-TIMS) for actinide isotope ratio analysis to improve accuracy and limits of detection will be presented. With respect to limits of detection, results on improving work function using various carbon additives will be reviewed and presented as well as developments in cavity ion source (as compared to standard flat ribbon filament ion source) for femto- and attogram levels of uranium, plutonium, and americium. With respect to accuracy, results on isotope ratio measurements of isotopes of uranium (relative accuracy of 0.3% to 0.01%) are presented with an example being U-234-Th-230 age-dating (NBL CRM 112-A). In this context, the importance of traceability (to the S.I. units) and the use of (certified) reference materials are emphasized. The focus of this presentation is on applications to nuclear safeguards / forensics.

  3. Flexible Modeling of Survival Data with Covariates Subject to Detection Limits via Multiple Imputation.

    Science.gov (United States)

    Bernhardt, Paul W; Wang, Huixia Judy; Zhang, Daowen

    2014-01-01

    Models for survival data generally assume that covariates are fully observed. However, in medical studies it is not uncommon for biomarkers to be censored at known detection limits. A computationally-efficient multiple imputation procedure for modeling survival data with covariates subject to detection limits is proposed. This procedure is developed in the context of an accelerated failure time model with a flexible seminonparametric error distribution. The consistency and asymptotic normality of the multiple imputation estimator are established and a consistent variance estimator is provided. An iterative version of the proposed multiple imputation algorithm that approximates the EM algorithm for maximum likelihood is also suggested. Simulation studies demonstrate that the proposed multiple imputation methods work well while alternative methods lead to estimates that are either biased or more variable. The proposed methods are applied to analyze the dataset from a recently-conducted GenIMS study.

  4. Zero-Forcing and Minimum Mean-Square Error Multiuser Detection in Generalized Multicarrier DS-CDMA Systems for Cognitive Radio

    Directory of Open Access Journals (Sweden)

    Lie-Liang Yang

    2008-01-01

    Full Text Available In wireless communications, multicarrier direct-sequence code-division multiple access (MC DS-CDMA constitutes one of the highly flexible multiple access schemes. MC DS-CDMA employs a high number of degrees-of-freedom, which are beneficial to design and reconfiguration for communications in dynamic communications environments, such as in the cognitive radios. In this contribution, we consider the multiuser detection (MUD in MC DS-CDMA, which motivates lowcomplexity, high flexibility, and robustness so that the MUD schemes are suitable for deployment in dynamic communications environments. Specifically, a range of low-complexity MUDs are derived based on the zero-forcing (ZF, minimum mean-square error (MMSE, and interference cancellation (IC principles. The bit-error rate (BER performance of the MC DS-CDMA aided by the proposed MUDs is investigated by simulation approaches. Our study shows that, in addition to the advantages provided by a general ZF, MMSE, or IC-assisted MUD, the proposed MUD schemes can be implemented using modular structures, where most modules are independent of each other. Due to the independent modular structure, in the proposed MUDs one module may be reconfigured without yielding impact on the others. Therefore, the MC DS-CDMA, in conjunction with the proposed MUDs, constitutes one of the promising multiple access schemes for communications in the dynamic communications environments such as in the cognitive radios.

  5. Zero-Forcing and Minimum Mean-Square Error Multiuser Detection in Generalized Multicarrier DS-CDMA Systems for Cognitive Radio

    Directory of Open Access Journals (Sweden)

    Wang Li-Chun

    2008-01-01

    Full Text Available Abstract In wireless communications, multicarrier direct-sequence code-division multiple access (MC DS-CDMA constitutes one of the highly flexible multiple access schemes. MC DS-CDMA employs a high number of degrees-of-freedom, which are beneficial to design and reconfiguration for communications in dynamic communications environments, such as in the cognitive radios. In this contribution, we consider the multiuser detection (MUD in MC DS-CDMA, which motivates lowcomplexity, high flexibility, and robustness so that the MUD schemes are suitable for deployment in dynamic communications environments. Specifically, a range of low-complexity MUDs are derived based on the zero-forcing (ZF, minimum mean-square error (MMSE, and interference cancellation (IC principles. The bit-error rate (BER performance of the MC DS-CDMA aided by the proposed MUDs is investigated by simulation approaches. Our study shows that, in addition to the advantages provided by a general ZF, MMSE, or IC-assisted MUD, the proposed MUD schemes can be implemented using modular structures, where most modules are independent of each other. Due to the independent modular structure, in the proposed MUDs one module may be reconfigured without yielding impact on the others. Therefore, the MC DS-CDMA, in conjunction with the proposed MUDs, constitutes one of the promising multiple access schemes for communications in the dynamic communications environments such as in the cognitive radios.

  6. Detection of spatial aggregation of cases of cancer from data on patients and health centres contained in the Minimum Basic Data Set

    Directory of Open Access Journals (Sweden)

    Pablo Fernández-Navarro

    2018-05-01

    Full Text Available The feasibility of the Minimum Basic Data Set (MBDS as a tool in cancer research was explored monitoring its incidence through the detection of spatial clusters. Case-control studies based on MBDS and marked point process were carried out with the focus on the residence of patients from the Prince of Asturias University Hospital in Alcalá de Henares (Madrid, Spain. Patients older than 39 years with diagnoses of stomach, colorectal, lung, breast, prostate, bladder and kidney cancer, melanoma and haematological tumours were selected. Geocoding of the residence address of the cases was done by locating them in the continuous population roll provided by the Madrid Statistical Institute and extracting the coordinates. The geocoded control group was a random sample of 10 controls per case matched by frequency of age and sex. To assess case clusters, differences in Ripley K functions between cases and controls were calculated. The spatial location of clusters was explored by investigating spatial intensity and its ratio between cases and controls. Results suggest the existence of an aggregation of cancers with a common risk factor such as tobacco smoking (lung, bladder and kidney cancers. These clusters were located in an urban area with high socioeconomic deprivation. The feasibility of designing and carrying out case-control studies from the MBDS is shown and we conclude that MBDS can be a useful epidemiological tool for cancer surveillance and identification of risk factors through case-control spatial point process studies.

  7. Uncertainty and minimum detectable concentrations using relative, absolute and K*0-IAEA standardization for the INAA laboratory of the ETRR-2

    International Nuclear Information System (INIS)

    Khalil, M. Y.

    2006-01-01

    Full text: The Instrumental Neutron Activation Analysis (INAA) Laboratory of Egypt Second Training and Research Reactor (ETRR-2) is increasingly requested to perform multi-element analysis to large number of samples from different origins. The INAA laboratory has to demonstrate competence by conforming to appropriate internationally and nationally accepted standards. The objective of this work is to determine the uncertainty budget and sensitivity of the INAA laboratory measurements. Concentrations of 9 elements; Mn, Na, K, Ca, Co, Cr, Fe, Rb, and Cs, were measured against a certified test sample. Relative, absolute, and Ko-IAEA standardization methods were employed and results compared. The flux was monitored using cadmium covered gold method, and multifoil (gold, nickel and zirconium) method. The combined and expanded uncertainties were estimated. Uncertainty of concentrations ranged between 2-21% depending on the standardization method used. The relative method, giving the lowest uncertainty, produced uncertainty budget between 2 and 11%. The minimum detectable concentration was the lowest for Cs ranging between 0.36 and 0.59 ppb and the highest being for K in the range of 0.32 to 8.64 ppm

  8. Detection limits of pollutants in water for PGNAA using Am-Be source

    International Nuclear Information System (INIS)

    Khelifi, R.; Amokrane, A.; Bode, P.

    2007-01-01

    A basic PGNAA facility with an Am-Be neutron source is described to analyze the pollutants in water. The properties of neutron flux were determined by MCNP calculations. In order to determine the efficiency curve of a HPGe detector, the prompt-gamma rays from chlorine were used and an exponential curve was fitted. The detection limits for typical water sample are also estimated using the statistical fluctuations of the background level in the areas of recorded the prompt-gamma spectrum

  9. Molecular techniques for detection and identification of pathogens in food: advantages and limitations

    OpenAIRE

    Palomino-Camargo, Carolina; Instituto de Ciencia y Tecnología de Alimentos, Facultad de Ciencias, Universidad Central de Venezuela. Caracas, Venezuela. Magíster en Ciencia y Tecnología de los Alimentos licenciada en Biología; González-Muñoz, Yuniesky; Instituto de Ciencia y Tecnología de Alimentos, Facultad de Ciencias, Universidad Central de Venezuela. Caracas, Venezuela. Ministerio del Poder Popular para la Alimentación. Caracas, Venezuela. licenciado en Ciencias de los Alimentos.

    2014-01-01

    Foodborne diseases, caused by pathogenic microorganisms, are a major public health problem worldwide. Microbiological methods commonly used in the detection of these foodborne pathogens are laborious and time consuming. This situation, coupled with the demand for immediate results and with technological advances, has led to the development of a wide range of rapid methods in recent decades. On this basis, this review describes the advantages and limitations of the main molecular methods used ...

  10. On the definition of the detection limit for non-selective determination of low activities

    International Nuclear Information System (INIS)

    Tschurlovits, M.

    1977-01-01

    Based on the latest published results, a detection limit which is easy to use in practical work without intensive consideration of counting statistics, is presented. The primary application of the given definition is the determination of gross activity. In the definition the error of the second kind as well as one-sided boundedness of the normal distribution are included. The results are given in graphical form. (orig.) [de

  11. The ground fault detection system for the Tore Supra toroidal pump limiter

    International Nuclear Information System (INIS)

    Zunino, K.; Cara, P.; Fejoz, P.; Hourtoule, J.; Loarer, T.; Pomaro, N.; Santagiustina, A.; Spuig, P.; Villecroze, F.

    2003-01-01

    The toroidal pump limiter (TPL) of Tore Supra is electrically insulated from the vacuum-vessel, to allow its polarization at a voltage of up to 1 kV. In order to monitor continuously the integrity of the TPL electrical insulation, an electronic diagnostic system called TPL ground fault detection system (GFDS) has been developed. The paper will report on the design and the operation experience of the GFD system and on the evolution of the TPL grounding

  12. Digitizing Tablet and Fahn–Tolosa–Marín Ratings of Archimedes Spirals have Comparable Minimum Detectable Change in Essential Tremor

    Directory of Open Access Journals (Sweden)

    Rodger J. Elble

    2017-07-01

    Full Text Available Background: Drawing Archimedes spirals is a popular and valid method of assessing action tremor in the upper limbs. We performed the first blinded comparison of Fahn–Tolosa–Marín (FTM ratings and tablet measures of essential tremor to determine if a digitizing tablet is better than 0–4 ratings in detecting changes in essential tremor that exceed random variability in tremor amplitude.Methods: The large and small spirals of FTM were drawn with each hand on two consecutive days by 14 men and four women (age 60±8.7 years [mean±SD] with mild to severe essential tremor. The drawings were simultaneously digitized with a digitizing tablet. Tremor in each digitized drawing was computed with spectral analysis in an independent laboratory, blinded to the clinical ratings. The mean peak-to-peak tremor displacement (cm in the four spirals and mean FTM ratings were compared statistically.Results: Test–retest intraclass correlations (ICCs (two-way random single measures, absolute agreement were excellent for the FTM ratings (ICC 0.90, 95% CI 0.76–0.96 and tablet (ICC 0.97, 95% CI 0.91–0.99. Log10 tremor amplitude (T and FTM were strongly correlated (logT = αFTM + β, α≈0.6, β≈–1.27, r = 0.94. The minimum detectable change for the tablet and FTM were 51% and 67% of the initial assessment.Discussion: Digitizing tablets are much more precise than clinical ratings, but this advantage is mitigated by the natural variability in tremor. Nevertheless, the digitizing tablet is a robust method of quantifying tremor that can be used in lieu of or in combination with clinical ratings.

  13. Evaluation on the detection limit of blood hemoglobin using photolepthysmography based on path-length optimization

    Science.gov (United States)

    Sun, Di; Guo, Chao; Zhang, Ziyang; Han, Tongshuai; Liu, Jin

    2016-10-01

    The blood hemoglobin concentration's (BHC) measurement using Photoplethysmography (PPG), which gets blood absorption to near infrared light from the instantaneous pulse of transmitted light intensity, has not been applied to the clinical use due to the non-enough precision. The main challenge might be caused of the non-enough stable pulse signal when it's very weak and it often varies in different human bodies or in the same body with different physiological states. We evaluated the detection limit of BHC using PPG as the measurement precision level, which can be considered as a best precision result because we got the relative stable subject's pulse signals recorded by using a spectrometer with high signal-to-noise ratio (SNR) level, which is about 30000:1 in short term. Moreover, we optimized the used pathlength using the theory based on optimum pathlength to get a better sensitivity to the absorption variation in blood. The best detection limit was evaluated as about 1 g/L for BHC, and the best SNR of pulse for in vivo measurement was about 2000:1 at 1130 and 1250 nm. Meanwhile, we conclude that the SNR of pulse signal should be better than 400:1 when the required detection limit is set to 5 g/L. Our result would be a good reference to the BHC measurement to get a desired BHC measurement precision of real application.

  14. Predictive inference for best linear combination of biomarkers subject to limits of detection.

    Science.gov (United States)

    Coolen-Maturi, Tahani

    2017-08-15

    Measuring the accuracy of diagnostic tests is crucial in many application areas including medicine, machine learning and credit scoring. The receiver operating characteristic (ROC) curve is a useful tool to assess the ability of a diagnostic test to discriminate between two classes or groups. In practice, multiple diagnostic tests or biomarkers are combined to improve diagnostic accuracy. Often, biomarker measurements are undetectable either below or above the so-called limits of detection (LoD). In this paper, nonparametric predictive inference (NPI) for best linear combination of two or more biomarkers subject to limits of detection is presented. NPI is a frequentist statistical method that is explicitly aimed at using few modelling assumptions, enabled through the use of lower and upper probabilities to quantify uncertainty. The NPI lower and upper bounds for the ROC curve subject to limits of detection are derived, where the objective function to maximize is the area under the ROC curve. In addition, the paper discusses the effect of restriction on the linear combination's coefficients on the analysis. Examples are provided to illustrate the proposed method. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  15. Detection and grading of dAVF: prospects and limitations of 3T MRI.

    Science.gov (United States)

    Bink, Andrea; Berkefeld, Joachim; Wagner, Marlies; You, Se-Jong; Ackermann, Hanns; Lorenz, Matthias W; Senft, Christian; du Mesnil de Rochemont, Richard

    2012-02-01

    DSA is currently the criterion standard for the assessment of dural arteriovenous fistulas (dAVF). Recently, evolving MRA techniques have emerged as a non-invasive alternative. The aim of this study is to assess the value of 3 T MRI in detecting and describing dAVF and to determine whether MRI can replace DSA as diagnostic procedure. A total of 19 patients with dAVF and 19 without dAVF underwent the same MRI protocol, including 3D time-of-flight MRA and time-resolved contrast-enhanced MRA. The images were evaluated retrospectively by three independent readers with different levels of experience blinded to clinical information. The readers assessed the presence, the site, the venous drainage and the feeders of dAVF. Sensitivity, specificity, accuracy, intertechnique and interobserver agreements were calculated. DAVF can be detected with high sensitivity, specificity and accuracy by experienced and also by less experienced readers. However, MRI has limitations when used for grading and evaluation of the angioarchitecture of the dAVF. Different experience, the limited resolution of MRI and its inability to selectively display arteries were the reasons for these limitations. With MRI dAVF can be detected reliably. Nevertheless, at present MRI can not fully replace DSA, especially for treatment planning.

  16. Detection limits for real-time source water monitoring using indigenous freshwater microalgae

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Jr, Miguel [ORNL; Greenbaum, Elias [ORNL

    2009-01-01

    This research identified toxin detection limits using the variable fluorescence of naturally occurring microalgae in source drinking water for five chemical toxins with different molecular structures and modes of toxicity. The five chemicals investigated were atrazine, Diuron, paraquat, methyl parathion, and potassium cyanide. Absolute threshold sensitivities of the algae for detection of the toxins in unmodified source drinking water were measured. Differential kinetics between the rate of action of the toxins and natural changes in algal physiology, such as diurnal photoinhibition, are significant enough that effects of the toxin can be detected and distinguished from the natural variance. This is true even for physiologically impaired algae where diminished photosynthetic capacity may arise from uncontrollable external factors such as nutrient starvation. Photoinhibition induced by high levels of solar radiation is a predictable and reversible phenomenon that can be dealt with using a period of dark adaption of 30 minutes or more.

  17. What are the minimum requirements for ketogenic diet services in resource-limited regions? Recommendations from the International League Against Epilepsy Task Force for Dietary Therapy.

    Science.gov (United States)

    Kossoff, Eric H; Al-Macki, Nabil; Cervenka, Mackenzie C; Kim, Heung D; Liao, Jianxiang; Megaw, Katherine; Nathan, Janak K; Raimann, Ximena; Rivera, Rocio; Wiemer-Kruel, Adelheid; Williams, Emma; Zupec-Kania, Beth A

    2015-09-01

    Despite the increasing use of dietary therapies for children and adults with refractory epilepsy, the availability of these treatments in developing countries with limited resources remains suboptimal. One possible contributory factor may be the costs. There is often reported a significant perceived need for a large ketogenic diet team, supplements, laboratory studies, and follow-up visits to provide this treatment. The 2009 Epilepsia Consensus Statement described ideal requirements for a ketogenic diet center, but in some situations this is not feasible. As a result, the International League Against Epilepsy (ILAE) Task Force on Dietary Therapy was asked to convene and provide practical, cost-effective recommendations for new ketogenic diet centers in resource-limited regions of the world. Wiley Periodicals, Inc. © 2015 International League Against Epilepsy.

  18. How low can the detection limit go with VPD-TXRF

    International Nuclear Information System (INIS)

    Wang, J.; Balazs, M.; Pianetta, P.; Baur, K.; Brennan, S.; Boone, T.; Rosamilia, J.

    2000-01-01

    The detection limit for synchrotron radiation total reflection x-ray fluorescence (TXRF) that can routinely be achieved for transition metals is about 8E7 atoms/cm 2 for a standard 1000 second counting time. This high sensitivity can be further improved by using a pre-concentration process such as vapor phase decomposition (VPD). The sensitivity enhancement of VPD-TXRF over TXRF is usually estimated from the ratio of the total wafer surface area to the instrumental sampling area on the wafer. For example, a 200 mm wafer with a 5 mm edge exclusion has a total surface area of 283.5 cm 2 . Assuming a sampling area of 0.126 cm 2 for the TXRF instrument at the Stanford Synchrotron Radiation Laboratory (SSRL) the gain in sensitivity for the VPD-TXRF technique will be 1 : 2250. This means, theoretically, that the TXRF detection limit of 8E7 atoms/cm 2 could be further reduced to 3.6 E4 atoms/cm 2 by applying this technique. During the VPD process, the contaminants on the wafer surface will be collected into a single droplet and dried on the wafer surface for TXRF analysis. However, impurities in the UPW (ultra pure water), chemicals or from handling cannot be ignored. Our investigation of wafers subjected, to different cleaning processes has revealed that background signals on the dry spot could arise from the VPD process itself. Therefore, the baseline determined by the purity of the UPW and starting chemicals limits the detection limits of VPD-SR-TXRF. (author)

  19. Detection limits of Legionella pneumophila in environmental samples after co-culture with Acanthamoeba polyphaga

    Science.gov (United States)

    2013-01-01

    Background The efficiency of recovery and the detection limit of Legionella after co-culture with Acanthamoeba polyphaga are not known and so far no investigations have been carried out to determine the efficiency of the recovery of Legionella spp. by co-culture and compare it with that of conventional culturing methods. This study aimed to assess the detection limits of co-culture compared to culture for Legionella pneumophila in compost and air samples. Compost and air samples were spiked with known concentrations of L. pneumophila. Direct culturing and co-culture with amoebae were used in parallel to isolate L. pneumophila and recovery standard curves for both methods were produced for each sample. Results The co-culture proved to be more sensitive than the reference method, detecting 102-103 L. pneumophila cells in 1 g of spiked compost or 1 m3 of spiked air, as compared to 105-106 cells in 1 g of spiked compost and 1 m3 of spiked air. Conclusions Co-culture with amoebae is a useful, sensitive and reliable technique to enrich L. pneumophila in environmental samples that contain only low amounts of bacterial cells. PMID:23442526

  20. Including Below Detection Limit Samples in Post Decommissioning Soil Sample Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hwan; Yim, Man Sung [KAIST, Daejeon (Korea, Republic of)

    2016-05-15

    To meet the required standards the site owner has to show that the soil at the facility has been sufficiently cleaned up. To do this one must know the contamination of the soil at the site prior to clean up. This involves sampling that soil to identify the degree of contamination. However there is a technical difficulty in determining how much decontamination should be done. The problem arises when measured samples are below the detection limit. Regulatory guidelines for site reuse after decommissioning are commonly challenged because the majority of the activity in the soil at or below the limit of detection. Using additional statistical analyses of contaminated soil after decommissioning is expected to have the following advantages: a better and more reliable probabilistic exposure assessment, better economics (lower project costs) and improved communication with the public. This research will develop an approach that defines an acceptable method for demonstrating compliance of decommissioned NPP sites and validates that compliance. Soil samples from NPP often contain censored data. Conventional methods for dealing with censored data sets are statistically biased and limited in their usefulness.

  1. Gravitational wave detection using laser interferometry beyond the standard quantum limit

    Science.gov (United States)

    Heurs, M.

    2018-05-01

    Interferometric gravitational wave detectors (such as advanced LIGO) employ high-power solid-state lasers to maximize their detection sensitivity and hence their reach into the universe. These sophisticated light sources are ultra-stabilized with regard to output power, emission frequency and beam geometry; this is crucial to obtain low detector noise. However, even when all laser noise is reduced as far as technically possible, unavoidable quantum noise of the laser still remains. This is a consequence of the Heisenberg Uncertainty Principle, the basis of quantum mechanics: in this case, it is fundamentally impossible to simultaneously reduce both the phase noise and the amplitude noise of a laser to arbitrarily low levels. This fact manifests in the detector noise budget as two distinct noise sources-photon shot noise and quantum radiation pressure noise-which together form a lower boundary for current-day gravitational wave detector sensitivities, the standard quantum limit of interferometry. To overcome this limit, various techniques are being proposed, among them different uses of non-classical light and alternative interferometer topologies. This article explains how quantum noise enters and manifests in an interferometric gravitational wave detector, and gives an overview of some of the schemes proposed to overcome this seemingly fundamental limitation, all aimed at the goal of higher gravitational wave event detection rates. This article is part of a discussion meeting issue `The promises of gravitational-wave astronomy'.

  2. The Impact of Including Below Detection Limit Samples in Post Decommissioning Soil Sample Analyses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Hwan; Yim, Man-Sung [KAIST, Daejeon (Korea, Republic of)

    2016-10-15

    To meet the required standards the site owner has to show that the soil at the facility has been sufficiently cleaned up. To do this one must know the contamination of the soil at the site prior to clean up. This involves sampling that soil to identify the degree of contamination. However there is a technical difficulty in determining how much decontamination should be done. The problem arises when measured samples are below the detection limit. Regulatory guidelines for site reuse after decommissioning are commonly challenged because the majority of the activity in the soil at or below the limit of detection. Using additional statistical analyses of contaminated soil after decommissioning is expected to have the following advantages: a better and more reliable probabilistic exposure assessment, better economics (lower project costs) and improved communication with the public. This research will develop an approach that defines an acceptable method for demonstrating compliance of decommissioned NPP sites and validates that compliance. Soil samples from NPP often contain censored data. Conventional methods for dealing with censored data sets are statistically biased and limited in their usefulness. In this research, additional methods are performed using real data from a monazite manufacturing factory.

  3. Estimation of the limit of detection with a bootstrap-derived standard error by a partly non-parametric approach. Application to HPLC drug assays

    DEFF Research Database (Denmark)

    Linnet, Kristian

    2005-01-01

    Bootstrap, HPLC, limit of blank, limit of detection, non-parametric statistics, type I and II errors......Bootstrap, HPLC, limit of blank, limit of detection, non-parametric statistics, type I and II errors...

  4. Estimation of the limit of detection in semiconductor gas sensors through linearized calibration models.

    Science.gov (United States)

    Burgués, Javier; Jiménez-Soto, Juan Manuel; Marco, Santiago

    2018-07-12

    The limit of detection (LOD) is a key figure of merit in chemical sensing. However, the estimation of this figure of merit is hindered by the non-linear calibration curve characteristic of semiconductor gas sensor technologies such as, metal oxide (MOX), gasFETs or thermoelectric sensors. Additionally, chemical sensors suffer from cross-sensitivities and temporal stability problems. The application of the International Union of Pure and Applied Chemistry (IUPAC) recommendations for univariate LOD estimation in non-linear semiconductor gas sensors is not straightforward due to the strong statistical requirements of the IUPAC methodology (linearity, homoscedasticity, normality). Here, we propose a methodological approach to LOD estimation through linearized calibration models. As an example, the methodology is applied to the detection of low concentrations of carbon monoxide using MOX gas sensors in a scenario where the main source of error is the presence of uncontrolled levels of humidity. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Radioactivity analyses and detection limit problems of environmental surveillance at a gas-cooled reactor

    International Nuclear Information System (INIS)

    Johnson, J.E.; Johnson, J.A.

    1988-01-01

    The lower limit of detection (LLD) values required by the USNRC for nuclear power facilities are often difficult to attain even using state of the art detection systems, e.g. the required LLD for I-131 in air is 70 fCi/m 3 . For a gas-cooled reactor where I-131 has never been observed in effluents, occasional false positive values occur due to: Counting statistics using high resolution Ge(Li) detectors, contamination from nuclear medicine releases and spectrum analysis systematic error. Statistically negative concentration values are often observed. These measurements must be included in the estimation of true mean values. For this and other reasons, the frequency distributions of this and other reasons, the frequency distributions of measured values appear to be log-normal. Difficulties in stating the true means and standard deviations are discussed for these situations

  6. Improved detection limit for {sup 59}Ni using the technique of accelerator mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Persson, Per; Erlandsson, Bengt; Hellborg, Ragnar; Kiisk, Madis; Larsson, Ragnar; Skog, Goeran; Stenstroem, Kristina [Lund Univ. (Sweden). Dept. of Nuclear Physics

    2002-11-01

    59 Ni is produced by neutron activation in the stainless steel close to the core of a nuclear reactor. To be able to classify the different parts of the reactor with respect to their content of long-lived radionuclides before final storage it is important to measure the 59 Ni level. Accelerator mass spectrometry is an ultra-sensitive method for counting atoms, suitable for 59 Ni measurements. Improvements in the reduction of the background and in the chemical reduction of cobalt, the interfering isobar, have been made. This chemical purification is essential when using small tandem accelerators, <3 MV, combined with the detection of characteristic projectile X-rays. These improvements have lowered the detection limit for 59 Ni by a factor of twenty compared with the first value reported for the Lund AMS facility. Material from the Swedish nuclear industry has been analysed and examples of the results are presented.

  7. Intrinsic spatial resolution limitations due to differences between positron emission position and annihilation detection localization

    International Nuclear Information System (INIS)

    Perez, Pedro; Malano, Francisco; Valente, Mauro

    2012-01-01

    Since its successful implementation for clinical diagnostic, positron emission tomography (PET) represents the most promising medical imaging technique. The recent major growth of PET imaging is mainly due to its ability to trace the biologic pathways of different compounds in the patient's body, assuming the patient can be labeled with some PET isotope. Regardless of the type of isotope, the PET imaging method is based on the detection of two 511-keV gamma photons being emitted in opposite directions, with almost 180 deg between them, as a consequence of electron-positron annihilation. Therefore, this imaging method is intrinsically limited by random uncertainties in spatial resolutions, related with differences between the actual position of positron emission and the location of the detected annihilation. This study presents an approach with the Monte Carlo method to analyze the influence of this effect on different isotopes of potential implementation in PET. (author)

  8. Diamond-based electrochemical aptasensor realizing a femtomolar detection limit of bisphenol A.

    Science.gov (United States)

    Ma, Yibo; Liu, Junsong; Li, Hongdong

    2017-06-15

    In this study, we designed and fabricated an electrochemical impedance aptasensor based on Au nanoparticles (Au-NPs) coated boron-doped diamond (BDD) modified with aptamers, and 6-mercapto-1-hexanol (MCH) for the detection of bisphenol A (BPA). The constructed BPA aptasensor exhibits good linearity from 1.0×10 -14 to 1.0×10 -9 molL -1 . The detection limitation of 7.2×10 -15 molL -1 was achieved, which can be attributed to the synergistic effect of combining BDD with Au-NPs, aptamers, and MCH. The examine results of BPA traces in Tris-HCl buffer and in milk, UV spectra of aptamer/BPA and interference test revealed that the novel aptasensors are of high sensitivity, specificity, stability and repeatability, which could be promising in practical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. New limits on the detection of a composition-dependent macroscopic force

    International Nuclear Information System (INIS)

    Boynton, P.; Aronson, S.

    1990-01-01

    We report here on a continuing experimental search for a macroscopic, composition dependent force coupling to ordinary matter. Within the phenomenological framework commonly employed -- a Yukawa representation of the interaction potential, and composition specified as some linear combination of baryon and lepton numbers -- the Index 3 experiment sets the most stringent upper limits yet on the interaction strength for coupling from B-2L to B-L, and for an interaction range from 200 m to 10 km. It is also the first null result to conflict with the marginal detection reported for the Index 1 experiment for all relevant values of the composition and range parameters

  10. Trace element analysis by EPMA in geosciences: detection limit, precision and accuracy

    Science.gov (United States)

    Batanova, V. G.; Sobolev, A. V.; Magnin, V.

    2018-01-01

    Use of the electron probe microanalyser (EPMA) for trace element analysis has increased over the last decade, mainly because of improved stability of spectrometers and the electron column when operated at high probe current; development of new large-area crystal monochromators and ultra-high count rate spectrometers; full integration of energy-dispersive / wavelength-dispersive X-ray spectrometry (EDS/WDS) signals; and the development of powerful software packages. For phases that are stable under a dense electron beam, the detection limit and precision can be decreased to the ppm level by using high acceleration voltage and beam current combined with long counting time. Data on 10 elements (Na, Al, P, Ca, Ti, Cr, Mn, Co, Ni, Zn) in olivine obtained on a JEOL JXA-8230 microprobe with tungsten filament show that the detection limit decreases proportionally to the square root of counting time and probe current. For all elements equal or heavier than phosphorus (Z = 15), the detection limit decreases with increasing accelerating voltage. The analytical precision for minor and trace elements analysed in olivine at 25 kV accelerating voltage and 900 nA beam current is 4 - 18 ppm (2 standard deviations of repeated measurements of the olivine reference sample) and is similar to the detection limit of corresponding elements. To analyse trace elements accurately requires careful estimation of background, and consideration of sample damage under the beam and secondary fluorescence from phase boundaries. The development and use of matrix reference samples with well-characterised trace elements of interest is important for monitoring and improving of the accuracy. An evaluation of the accuracy of trace element analyses in olivine has been made by comparing EPMA data for new reference samples with data obtained by different in-situ and bulk analytical methods in six different laboratories worldwide. For all elements, the measured concentrations in the olivine reference sample

  11. Picomolar detection limits with current-polarized Pb2+ ion-selective membranes.

    Science.gov (United States)

    Pergel, E; Gyurcsányi, R E; Tóth, K; Lindner, E

    2001-09-01

    Minor ion fluxes across ion-selective membranes bias submicromolar activity measurements with conventional ion-selective electrodes. When ion fluxes are balanced, the lower limit of detection is expected to be dramatically improved. As proof of principle, the flux of lead ions across an ETH 5435 ionophore-based lead-selective membrane was gradually compensated by applying a few nanoamperes of galvanostatic current. When the opposite ion fluxes were matched, and the undesirable leaching of primary ions was eliminated, Nernstian response down to 3 x 10(-12) M was achieved.

  12. Analysis of background components in Ge-spectrometry and their influence on detection limits

    Energy Technology Data Exchange (ETDEWEB)

    Heusser, G [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany)

    1997-03-01

    In low radioactivity measurements the system own background of the spectrometer is, besides the counting efficiency, the limiting factor for the achievable sensitivity. Since the latter is mostly fixed, background reduction is the only way to gain sensitivity, although it is inversely proportional only to the square root of the background rate but directly proportional to the counting efficiency. A thorough understanding of the background sources and their quantitative contribution helps to choose the most adequate suppression method in order to reach a certain required level of detection limit. For Ge-spectrometry the background can be reduced by 5 to 6 orders of magnitude compared to the unshielded case applying state-of-the-art techniques. This reduction factor holds for the continuous background spectrum as well as for the line background as demonstrated for a Ge detector of the Heidelberg-Moscow double beta decay experiment. (orig./DG)

  13. First direct detection limits on sub-GeV dark matter from XENON10.

    Science.gov (United States)

    Essig, Rouven; Manalaysay, Aaron; Mardon, Jeremy; Sorensen, Peter; Volansky, Tomer

    2012-07-13

    The first direct detection limits on dark matter in the MeV to GeV mass range are presented, using XENON10 data. Such light dark matter can scatter with electrons, causing ionization of atoms in a detector target material and leading to single- or few-electron events. We use 15  kg day of data acquired in 2006 to set limits on the dark-matter-electron scattering cross section. The strongest bound is obtained at 100 MeV where σ(e)dark-matter masses between 20 MeV and 1 GeV are bounded by σ(e)dark-matter candidates with masses well below the GeV scale.

  14. Power-limited low-thrust trajectory optimization with operation point detection

    Science.gov (United States)

    Chi, Zhemin; Li, Haiyang; Jiang, Fanghua; Li, Junfeng

    2018-06-01

    The power-limited solar electric propulsion system is considered more practical in mission design. An accurate mathematical model of the propulsion system, based on experimental data of the power generation system, is used in this paper. An indirect method is used to deal with the time-optimal and fuel-optimal control problems, in which the solar electric propulsion system is described using a finite number of operation points, which are characterized by different pairs of thruster input power. In order to guarantee the integral accuracy for the discrete power-limited problem, a power operation detection technique is embedded in the fourth-order Runge-Kutta algorithm with fixed step. Moreover, the logarithmic homotopy method and normalization technique are employed to overcome the difficulties caused by using indirect methods. Three numerical simulations with actual propulsion systems are given to substantiate the feasibility and efficiency of the proposed method.

  15. STATISTICAL METHODS FOR ENVIRONMENTAL APPLICATIONS USING DATA SETS WITH BELOW DETECTION LIMIT OBSERVATIONS AS INCORPORTED IN PROUCL 4.0

    Science.gov (United States)

    Nondetect (ND) or below detection limit (BDL) results cannot be measured accurately, and, therefore, are reported as less than certain detection limit (DL) values. However, since the presence of some contaminants (e.g., dioxin) in environmental media may pose a threat to human he...

  16. Application and Limitations of GPS Radio Occultation (GPS-RO) Data for Atmospheric Boundary Layer Height Detection over the Arctic.

    Science.gov (United States)

    Ganeshan, M.; Wu, D. L.

    2014-12-01

    Due to recent changes in the Arctic environment, it is important to monitor the atmospheric boundary layer (ABL) properties over the Arctic Ocean, especially to explore the variability in ABL clouds (such as sensitivity and feedback to sea ice loss). For example, radiosonde and satellite observations of the Arctic ABL height (and low-cloud cover) have recently suggested a positive response to sea ice loss during October that may not occur during the melt season (June-September). Owing to its high vertical and spatiotemporal resolution, an independent ABL height detection algorithm using GPS Radio Occultation (GPS-RO) refractivity in the Arctic is explored. Similar GPS-RO algorithms developed previously typically define the level of the most negative moisture gradient as the ABL height. This definition is favorable for subtropical oceans where a stratocumulus-topped ABL is often capped by a layer of sharp moisture lapse rate (coincident with the temperature inversion). The Arctic Ocean is also characterized by stratocumulus cloud cover, however, the specific humidity does not frequently decrease in the ABL capping inversion. The use of GPS-RO refractivity for ABL height retrieval therefore becomes more complex. During winter months (December-February), when the total precipitable water in the troposphere is a minimum, a fairly straightforward algorithm for ABL height retrieval is developed. The applicability and limitations of this method for other seasons (Spring, Summer, Fall) is determined. The seasonal, interannual and spatial variability in the GPS-derived ABL height over the Arctic Ocean, as well as its relation to the underlying surface (ice vs. water), is investigated. The GPS-RO profiles are also explored for the evidence of low-level moisture transport in the cold Arctic environment.

  17. RCRA materials analysis by laser-induced breakdown spectroscopy: Detection limits in soils

    International Nuclear Information System (INIS)

    Koskelo, A.; Cremers, D.A.

    1994-01-01

    The goal of the Technical Task Plan (TTP) that this report supports is research, development, testing and evaluation of a portable analyzer for RCRA and other metals. The instrumentation to be built will be used for field-screening of soils. Data quality is expected to be suitable for this purpose. The data presented in this report were acquired to demonstrate the detection limits for laser-induced breakdown spectroscopy (LIBS) of soils using instrument parameters suitable for fieldable instrumentation. The data are not expected to be the best achievable with the high pulse energies available in laboratory lasers. The report presents work to date on the detection limits for several elements in soils using LIBS. The elements targeted in the Technical Task Plan are antimony, arsenic, beryllium, cadmium, chromium, lead, selenium, and zirconium. Data for these elements are presented in this report. Also included are other data of interest to potential customers for the portable LIBS apparatus. These data are for barium, mercury, cesium and strontium. Data for uranium and thorium will be acquired during the tasks geared toward mixed waste characterization

  18. Analysis of detection limit to time-resolved coherent anti-Stokes Raman scattering nanoscopy

    International Nuclear Information System (INIS)

    Liu Wei; Liu Shuang-Long; Chen Dan-Ni; Niu Han-Ben

    2014-01-01

    In the implementation of CARS nanoscopy, signal strength decreases with focal volume size decreasing. A crucial problem that remains to be solved is whether the reduced signal generated in the suppressed focal volume can be detected. Here reported is a theoretical analysis of detection limit (DL) to time-resolved CARS (T-CARS) nanoscopy based on our proposed additional probe-beam-induced phonon depletion (APIPD) method for the low concentration samples. In order to acquire a detailed shot-noise limited signal-to-noise (SNR) and the involved parameters to evaluate DL, the T-CARS process is described with full quantum theory to estimate the extreme power density levels of the pump and Stokes beams determined by saturation behavior of coherent phonons, which are both actually on the order of ∼ 10 9 W/cm 2 . When the pump and Stokes intensities reach such values and the total intensity of the excitation beams arrives at a maximum tolerable by most biological samples in a certain suppressed focal volume (40-nm suppressed focal scale in APIPD method), the DL correspondingly varies with exposure time, for example, DL values are 10 3 and 10 2 when exposure times are 20 ms and 200 ms respectively. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  19. Calculation of risk-based detection limits for radionuclides in the liquid effluents from Korean nuclear power plants

    International Nuclear Information System (INIS)

    Cheong, Jae Hak

    2017-01-01

    In order to review if present detection limits of radionuclides in liquid effluent from nuclear power plants are effective enough to warrant compliance with regulatory discharge limits, a risk-based approach is developed to derive a new detection limit for each radionuclide based on radiological criteria. Equations and adjustment factors are also proposed to discriminate the validity of the detection limits for multiple radionuclides in the liquid effluent with or without consideration of the nuclide composition. From case studies to three nuclear power plants in Korea with actual operation data from 2006 to 2015, the present detection limits have turned out to be effective for Hanul Unit 1 but may not be sensitive enough for Kori Unit 1 (8 out of 14 radionuclides) and Wolsong Unit 1 (9 out of 42 radionuclides). However, it is shown that the present detection limits for the latter two nuclear power plants can be justified, if credit is given to the radionuclide composition. Otherwise, consideration should be given to adjustment of the present detection limits. The risk-based approach of this study can be used to determine the validity of established detection limits of a specific nuclear power plant. (author)

  20. The study on the lidar's detection limit for Iodine Gas

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong-lyul; Baik, Seung-Hoon; Park, Seung-Kyu; Park, Nak-Gyu; Ahn, Yong-Jin [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    A powerful and reliable tool for range-resolved remote sensing of gas concentrations that has proven its capabilities in a variety of studies is the differential absorption lidar (DIAL). Differential absorption lidar (DIAL) is frequently used for atmospheric gas monitoring to detect impurities such as nitrogen dioxide, sulfur dioxide, iodine, and ozone. DIAL can measure air pollutant concentrations with a high spatial resolution by adopting two laser systems with different degrees of absorption between the two different wavelengths. The absorption of the reference wavelength is very weak, while the absorption of the other wavelength is very strong. In this paper, we measured the limit of detection capability of our designed DIAL system. The DIAL measurements were performed using a target iodine cell in the laboratory. We confirmed that the concentration of iodine gas ratio increased after the laser passed through the iodine cell. The system of DIAL(Differential Absorption Lidar) was effective to detect the iodine gas. We obtained the signals from the iodine target cell and the lidar signal from the iodine target cell was proportional to frequency locking ratios.

  1. Confocal laser-induced fluorescence detector for narrow capillary system with yoctomole limit of detection.

    Science.gov (United States)

    Weaver, Mitchell T; Lynch, Kyle B; Zhu, Zaifang; Chen, Huang; Lu, Joann J; Pu, Qiaosheng; Liu, Shaorong

    2017-04-01

    Laser-induced fluorescence (LIF) detectors for low-micrometer and sub-micrometer capillary on-column detection are not commercially available. In this paper, we describe in details how to construct a confocal LIF detector to address this issue. We characterize the detector by determining its limit of detection (LOD), linear dynamic range (LDR) and background signal drift; a very low LOD (~70 fluorescein molecules or 12 yoctomole fluorescein), a wide LDR (greater than 3 orders of magnitude) and a small background signal drift (~1.2-fold of the root mean square noise) are obtained. For detecting analytes inside a low-micrometer and sub-micrometer capillary, proper alignment is essential. We present a simple protocol to align the capillary with the optical system and use the position-lock capability of a translation stage to fix the capillary in position during the experiment. To demonstrate the feasibility of using this detector for narrow capillary systems, we build a 2-μm-i.d. capillary flow injection analysis (FIA) system using the newly developed LIF prototype as a detector and obtain an FIA LOD of 14 zeptomole fluorescein. We also separate a DNA ladder sample by bare narrow capillary - hydrodynamic chromatography and use the LIF prototype to monitor the resolved DNA fragments. We obtain not only well-resolved peaks but also the quantitative information of all DNA fragments. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. A novel dNTP-limited PCR and HRM assay to detect Williams-Beuren syndrome.

    Science.gov (United States)

    Zhang, Lichen; Zhang, Xiaoqing; You, Guoling; Yu, Yongguo; Fu, Qihua

    2018-06-01

    Williams-Beuren syndrome (WBS) is caused by a microdeletion of chromosome arm 7q11.23. A rapid and inexpensive genotyping method to detect microdeletion on 7q11.23 needs to be developed for the diagnosis of WBS. This study describes the development of a new type of molecular diagnosis method to detect microdeletion on 7q11.23 based upon high-resolution melting (HRM). Four genes on 7q11.23 were selected as the target genes for the deletion genotyping. dNTP-limited duplex PCR was used to amplify the reference gene, CFTR, and one of the four genes respectively on 7q11.23. An HRM assay was performed on the PCR products, and the height ratio of the negative derivative peaks between the target gene and reference gene was employed to analyze the copy number variation of the target region. A new genotyping method for detecting 7q11.23 deletion was developed based upon dNTP-limited PCR and HRM, which cost only 96 min. Samples from 15 WBS patients and 12 healthy individuals were genotyped by this method in a blinded fashion, and the sensitivity and specificity was 100% (95% CI, 0.80-1, and 95% CI, 0.75-1, respectively) which was proved by CytoScan HD array. The HRM assay we developed is an rapid, inexpensive, and highly accurate method for genotyping 7q11.23 deletion. It is potentially useful in the clinical diagnosis of WBS. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. WE-H-207A-09: Theoretical Limits to Molecular Biomarker Detection Using Magnetic Nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Weaver, J [Dartmouth-Hitchcock Medical Center, Lebanon, NH (United States); Geisel School of Medicine, Dartmouth College, Hanover, NH (United States)

    2016-06-15

    Purpose: Estimate the limits of molecular biomarker detection using magnetic nanoparticle methods like in vivo ELISA. Methods: Magnetic nanoparticles in an alternating magnetic field produce a magnetization that can be detected at exceedingly low levels because the signal at the harmonic frequencies is uniquely produced by the nanoparticles. Because the magnetization can also be used to characterize the nanoparticle rotational freedom, the bound state can be found. If the nanoparticles are coated with molecules that bind the desired biomarker, the rotational freedom reflects the biomarker concentration. The irreducible noise limit is the thermal noise or Johnson noise of the tissue and the contrast that can be measured must be larger than that limit. The contrast produced is a function of the applied field and depends strongly on nanoparticle volume. We have estimated the contrast using a Langevin function of a single composite variable to approximate the full stochastic Langevin equation for nanoparticle dynamics. Results: The thermal noise for a bandwidth reasonable for spectroscopy suggests mid zeptomolar (10–21) to low attomolar (10–18) concentrations can be measured in a volume that is 10cm in scale. The suggested sensitivity is far below the physiologically concentrations of almost all critical biomarkers including cytokines (picomolar), hormones (nanomolar) and heat shock proteins. Conclusion: The sensitivity of in vivo ELISA concentration measurements should be sufficient to measure physiological concentrations of critical biomarkers like cytokines in vivo. Further the sensitivity should be sufficient to measure concentrations of other biomarkers that are six to eight orders of magnitude lower in concentration than immune signaling molecules like cytokines. NIH - 1U54CA151662-01 Department of Radiology.

  4. Limit of detection of a fiber optics gyroscope using a super luminescent radiation source

    International Nuclear Information System (INIS)

    Sandoval R, G.E.; Nikolaev, V.A.

    2003-01-01

    The main objective of this work is to establish the dependence of characteristics of the fiber optics gyroscope (FOG) with respect to the parameters of the super luminescent emission source based on doped optical fiber with rare earth elements (Super luminescent Fiber Source, SFS), argument the pumping rate election of the SFS to obtain characteristics limits of the FOG sensibility. By using this type of emission source in the FOG is recommend to use the rate when the direction of the pumping signal coincide with the super luminescent signal. The most results are the proposition and argumentation of the SFS election as emission source to be use in the FOG of the phase type. Such a decision allow to increase the characteristics of the FOG sensibility in comparison with the use of luminescent source of semiconductors emission which are extensively used in the present time. The use of emission source of the SFS type allow to come closer to the threshold of the obtained sensibility limit (detection limit) which is determined with the shot noise. (Author)

  5. Limit of detection of a fiber optics gyroscope using a super luminescent radiation source

    CERN Document Server

    Sandoval, G E

    2003-01-01

    The main objective of this work is to establish the dependence of characteristics of the fiber optics gyroscope (FOG) with respect to the parameters of the super luminescent emission source based on doped optical fiber with rare earth elements (Super luminescent Fiber Source, SFS), argument the pumping rate election of the SFS to obtain characteristics limits of the FOG sensibility. By using this type of emission source in the FOG is recommend to use the rate when the direction of the pumping signal coincide with the super luminescent signal. The most results are the proposition and argumentation of the SFS election as emission source to be use in the FOG of the phase type. Such a decision allow to increase the characteristics of the FOG sensibility in comparison with the use of luminescent source of semiconductors emission which are extensively used in the present time. The use of emission source of the SFS type allow to come closer to the threshold of the obtained sensibility limit (detection limit) which i...

  6. 40 CFR Appendix B to Part 136 - Definition and Procedure for the Determination of the Method Detection Limit-Revision 1.11

    Science.gov (United States)

    2010-07-01

    ... calculated method detection limit. To insure that the estimate of the method detection limit is a good...) where: MDL = the method detection limit t(n-1,1- α=.99) = the students' t value appropriate for a 99... Determination of the Method Detection Limit-Revision 1.11 B Appendix B to Part 136 Protection of Environment...

  7. Evaluation of MidIR fibre optic reflectance: Detection limit, reproducibility and binary mixture discrimination

    Science.gov (United States)

    Sessa, Clarimma; Bagán, Héctor; García, José Francisco

    2013-11-01

    MidIR fibre optic reflectance (MidIR-FORS) is a promising analytical technique in the field of science conservation, especially because it is non-destructive. Another advantage of MidIR-FORS is that the obtained information is representative, as a large amount of spectral data can be collected. Although the technique has a high potential and is almost routinely applied, its quality parameters have not been thoroughly studied in the specific application of analysis of artistic materials. The objective of this study is to evaluate the instrumental capabilities of MidIR-FORS for the analysis of artwork materials in terms of detection limit, reproducibility, and mixture characterisation. The study has been focused on oil easel painting and several paints of known composition have been analysed. Paint layers include blue pigments not only because of their important role along art history, but also because their physical and spectroscopic characteristics allow a better evaluation of the MidIR-FORS capabilities. The results of the analysis indicate that MidIR-FORS supplies a signal affected by different factors, such as the optical, morphological and physical properties of the surface, in addition to the composition of materials analysed. Consequently, the detection limits established are relatively high for artistic objects (Prussian blue - PB 2.1-6.5%; Phthalocyanine blue - Pht 6.3-10.2%; synthetic Ultramarine blue - UM 12.1%) and may therefore lead to an incomplete description of the artwork. Reproducibility of the technique over time and across surface has been determined. The results show that the major sources of dispersion are the heterogeneity of the pigments distribution, physical features, and band shape distortions. The total dispersion is around 4% for the most intense bands (oil) and increases up to 26% when weak or overlapped bands are considered (PB, Pht, UM). The application of different pre-treatments (cutoff of fibres absorption, Savizky-Golay smoothing

  8. Composite Estimation for Single-Index Models with Responses Subject to Detection Limits

    KAUST Repository

    Tang, Yanlin; Wang, Huixia Judy; Liang, Hua

    2017-01-01

    We propose a semiparametric estimator for single-index models with censored responses due to detection limits. In the presence of left censoring, the mean function cannot be identified without any parametric distributional assumptions, but the quantile function is still identifiable at upper quantile levels. To avoid parametric distributional assumption, we propose to fit censored quantile regression and combine information across quantile levels to estimate the unknown smooth link function and the index parameter. Under some regularity conditions, we show that the estimated link function achieves the non-parametric optimal convergence rate, and the estimated index parameter is asymptotically normal. The simulation study shows that the proposed estimator is competitive with the omniscient least squares estimator based on the latent uncensored responses for data with normal errors but much more efficient for heavy-tailed data under light and moderate censoring. The practical value of the proposed method is demonstrated through the analysis of a human immunodeficiency virus antibody data set.

  9. Towards improving the detection limit of electron paramagnetic resonance (EPR) dosimetry of drywall (wallboard)

    Energy Technology Data Exchange (ETDEWEB)

    Mistry, R.; Thompson, J.W. [Dept. of Medical Physics and Applied Radiation Sciences, McMaster Univ., Hamilton, Ontario (Canada); Rink, W.J. [School of Geography and Earth Sciences, McMaster Univ., Hamilton, Ontario (Canada); Boreham, D. [Dept. of Medical Physics and Applied Radiation Sciences, McMaster Univ., Hamilton, Ontario (Canada)

    2009-07-01

    The intensity of the electron paramagnetic resonance (EPR) line corresponding to the carbonate free radical (CO{sub 3}{sup -}) in gypsum (CaSO{sub 4}{center_dot}2H{sub 2}O) drywall was previously shown to be proportional to absorbed dose. Heating irradiated drywall reduces the radiosensitive signal of the CO{sub 3}{sup -} radical. The response of the CO{sub 3}{sup -} EPR line to heat treatments is being studied in order to determine a background for an arbitrary drywall sample. Ultimately this is expected to improve the precision of dose measurements with drywall and to reduce the detection limit. Controlled heating of irradiated drywall was performed at temperatures between 50{sup o}C and 100{sup o}C. Although higher temperatures reduce the radiosensitive signal rapidly, the non-radiosensitive EPR signals are affected dramatically as well, presumably due to a phrase change from gypsum to plaster of Paris to anhydrite. (author)

  10. Composite Estimation for Single-Index Models with Responses Subject to Detection Limits

    KAUST Repository

    Tang, Yanlin

    2017-11-03

    We propose a semiparametric estimator for single-index models with censored responses due to detection limits. In the presence of left censoring, the mean function cannot be identified without any parametric distributional assumptions, but the quantile function is still identifiable at upper quantile levels. To avoid parametric distributional assumption, we propose to fit censored quantile regression and combine information across quantile levels to estimate the unknown smooth link function and the index parameter. Under some regularity conditions, we show that the estimated link function achieves the non-parametric optimal convergence rate, and the estimated index parameter is asymptotically normal. The simulation study shows that the proposed estimator is competitive with the omniscient least squares estimator based on the latent uncensored responses for data with normal errors but much more efficient for heavy-tailed data under light and moderate censoring. The practical value of the proposed method is demonstrated through the analysis of a human immunodeficiency virus antibody data set.

  11. Amorphous semiconductors for particle detection: Physical and technical limits and possibilities

    International Nuclear Information System (INIS)

    Equer, B.; Karar, A.

    1989-01-01

    Amorphous silicon is used, at an industrial level, in at least three different fields of application: photovoltaic cells, flat TV screens and line scanners for image processing. In the last two cases, thin film transistors (TFT) are produced with the same technology. Particle detection with amorphous silicon has been demonstrated, but present performances are limited to ionizing particles. In this paper, we discuss the physical basis of amorphous semiconductors and the possible future development that can be expected on the basis of the existing technology. It is concluded that substitution of amorphous for crystalline silicon brings no clear advantage, if possible at all. Positive assets are to be found in using specific properties of thin layers: large area structures like arrays of photodiodes with associated readout are in the state of the art; vertical structures alternating layers of differently doped materials and/or of different semiconductors can be produced by the same technique. The development of large area pixel detectors is technically feasible but requires a very large effort. A joint development effort with industries involved in X-ray detection and 2D photodetectors might be the most appropriate solution. (orig.)

  12. Potential and limits of Raman spectroscopy for carotenoid detection in microorganisms: implications for astrobiology

    Science.gov (United States)

    Jehlička, Jan; Edwards, Howell G. M.; Osterrothová, Kateřina; Novotná, Julie; Nedbalová, Linda; Kopecký, Jiří; Němec, Ivan; Oren, Aharon

    2014-01-01

    In this paper, it is demonstrated how Raman spectroscopy can be used to detect different carotenoids as possible biomarkers in various groups of microorganisms. The question which arose from previous studies concerns the level of unambiguity of discriminating carotenoids using common Raman microspectrometers. A series of laboratory-grown microorganisms of different taxonomic affiliation was investigated, such as halophilic heterotrophic bacteria, cyanobacteria, the anoxygenic phototrophs, the non-halophilic heterotrophs as well as eukaryotes (Ochrophyta, Rhodophyta and Chlorophyta). The data presented show that Raman spectroscopy is a suitable tool to assess the presence of carotenoids of these organisms in cultures. Comparison is made with the high-performance liquid chromatography approach of analysing pigments in extracts. Direct measurements on cultures provide fast and reliable identification of the pigments. Some of the carotenoids studied are proposed as tracers for halophiles, in contrast with others which can be considered as biomarkers of other genera. The limits of application of Raman spectroscopy are discussed for a few cases where the current Raman spectroscopic approach does not allow discriminating structurally very similar carotenoids. The database reported can be used for applications in geobiology and exobiology for the detection of pigment signals in natural settings. PMID:25368348

  13. Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits

    Directory of Open Access Journals (Sweden)

    Peeyush Sahay

    2009-10-01

    Full Text Available Breath analysis, a promising new field of medicine and medical instrumentation, potentially offers noninvasive, real-time, and point-of-care (POC disease diagnostics and metabolic status monitoring. Numerous breath biomarkers have been detected and quantified so far by using the GC-MS technique. Recent advances in laser spectroscopic techniques and laser sources have driven breath analysis to new heights, moving from laboratory research to commercial reality. Laser spectroscopic detection techniques not only have high-sensitivity and high-selectivity, as equivalently offered by the MS-based techniques, but also have the advantageous features of near real-time response, low instrument costs, and POC function. Of the approximately 35 established breath biomarkers, such as acetone, ammonia, carbon dioxide, ethane, methane, and nitric oxide, 14 species in exhaled human breath have been analyzed by high-sensitivity laser spectroscopic techniques, namely, tunable diode laser absorption spectroscopy (TDLAS, cavity ringdown spectroscopy (CRDS, integrated cavity output spectroscopy (ICOS, cavity enhanced absorption spectroscopy (CEAS, cavity leak-out spectroscopy (CALOS, photoacoustic spectroscopy (PAS, quartz-enhanced photoacoustic spectroscopy (QEPAS, and optical frequency comb cavity-enhanced absorption spectroscopy (OFC-CEAS. Spectral fingerprints of the measured biomarkers span from the UV to the mid-IR spectral regions and the detection limits achieved by the laser techniques range from parts per million to parts per billion levels. Sensors using the laser spectroscopic techniques for a few breath biomarkers, e.g., carbon dioxide, nitric oxide, etc. are commercially available. This review presents an update on the latest developments in laser-based breath analysis.

  14. Left ventricular time volume curve analysis in the detection of limited ischaemic heart disease

    International Nuclear Information System (INIS)

    Liechtenstein, M.; Blanchett, W.; Andrews, J.; Hunt, D.

    1982-01-01

    The aim of the study was to determine whether limited coronary artery disease (CAD) could be accurately detected using the Cardiac Gated Blood Pool (CGBP) scan with exercise. Regional left ventricular time volume curves (RLTVD) were generated from 52 studies (46 patients: 22 normals, 24 abnormals). The parameters assessed both globally and regionally and at rest (R) and exercise (Ex) were: (1) the ejection fraction (EF) (2) the change in ejection fraction from R to Ex (δEF) (3) an early contraction index (ECI) (4) a maximal emptying index (DR) and (5) a maximal refilling index (AR). After careful analysis of these parameters it was decided that our diagnostic criteria would rely on the following: (1) the EF at R and Ex (2) the δ EF (3) the ECI at Ex (4) the AR at Ex This study showed that both the sensitivity and the specificity of the CGBP scan can be improved considerably with the inclusion of RLTVC from the levels obtained when the EF parameters alone are considered. It is possible with this technique to accurately diagnose limited CAD. (Author)

  15. Investigation of detection limits for diffuse optical tomography systems: II. Analysis of slab and cup geometry for breast imaging.

    Science.gov (United States)

    Ziegler, Ronny; Brendel, Bernhard; Rinneberg, Herbert; Nielsen, Tim

    2009-01-21

    Using a statistical (chi-square) test on simulated data and a realistic noise model derived from the system's hardware we study the performance of diffuse optical tomography systems for fluorescence imaging. We compare the predicted smallest size of detectable lesions at various positions in slab and cup geometry and model how detection sensitivity depends on breast compression and lesion fluorescence contrast. Our investigation shows that lesion detection is limited by relative noise in slab geometry and by absolute noise in cup geometry.

  16. Detection of maximum loadability limits and weak buses using Chaotic PSO considering security constraints

    International Nuclear Information System (INIS)

    Acharjee, P.; Mallick, S.; Thakur, S.S.; Ghoshal, S.P.

    2011-01-01

    Highlights: → The unique cost function is derived considering practical Security Constraints. → New innovative formulae of PSO parameters are developed for better performance. → The inclusion and implementation of chaos in PSO technique is original and unique. → Weak buses are identified where FACTS devices can be implemented. → The CPSO technique gives the best performance for all the IEEE standard test systems. - Abstract: In the current research chaotic search is used with the optimization technique for solving non-linear complicated power system problems because Chaos can overcome the local optima problem of optimization technique. Power system problem, more specifically voltage stability, is one of the practical examples of non-linear, complex, convex problems. Smart grid, restructured energy system and socio-economic development fetch various uncertain events in power systems and the level of uncertainty increases to a great extent day by day. In this context, analysis of voltage stability is essential. The efficient method to assess the voltage stability is maximum loadability limit (MLL). MLL problem is formulated as a maximization problem considering practical security constraints (SCs). Detection of weak buses is also important for the analysis of power system stability. Both MLL and weak buses are identified by PSO methods and FACTS devices can be applied to the detected weak buses for the improvement of stability. Three particle swarm optimization (PSO) techniques namely General PSO (GPSO), Adaptive PSO (APSO) and Chaotic PSO (CPSO) are presented for the comparative study with obtaining MLL and weak buses under different SCs. In APSO method, PSO-parameters are made adaptive with the problem and chaos is incorporated in CPSO method to obtain reliable convergence and better performances. All three methods are applied on standard IEEE 14 bus, 30 bus, 57 bus and 118 bus test systems to show their comparative computing effectiveness and

  17. Design for minimum energy in interstellar communication

    Science.gov (United States)

    Messerschmitt, David G.

    2015-02-01

    Microwave digital communication at interstellar distances is the foundation of extraterrestrial civilization (SETI and METI) communication of information-bearing signals. Large distances demand large transmitted power and/or large antennas, while the propagation is transparent over a wide bandwidth. Recognizing a fundamental tradeoff, reduced energy delivered to the receiver at the expense of wide bandwidth (the opposite of terrestrial objectives) is advantageous. Wide bandwidth also results in simpler design and implementation, allowing circumvention of dispersion and scattering arising in the interstellar medium and motion effects and obviating any related processing. The minimum energy delivered to the receiver per bit of information is determined by cosmic microwave background alone. By mapping a single bit onto a carrier burst, the Morse code invented for the telegraph in 1836 comes closer to this minimum energy than approaches used in modern terrestrial radio. Rather than the terrestrial approach of adding phases and amplitudes increases information capacity while minimizing bandwidth, adding multiple time-frequency locations for carrier bursts increases capacity while minimizing energy per information bit. The resulting location code is simple and yet can approach the minimum energy as bandwidth is expanded. It is consistent with easy discovery, since carrier bursts are energetic and straightforward modifications to post-detection pattern recognition can identify burst patterns. Time and frequency coherence constraints leading to simple signal discovery are addressed, and observations of the interstellar medium by transmitter and receiver constrain the burst parameters and limit the search scope.

  18. Proposal for a methodology for the determination of the Detection Limit: Case of bulks detector for the Chlorothalonil

    International Nuclear Information System (INIS)

    Gonzalez G, J.; Parra M, C.M.; Romero R, R.M.

    1998-01-01

    As it usually found in the literature, the Lower Detection Limit for an analytical method is obtained by means of a simple statistical exercise whose value is seldom attained in practice. For this reason a method was designed for achieving a Practical Lower Detection Limit for the lowest concentration of the compound that could be detected, S= 2 R, with a probability of at least, 0.90. A methodological design was formulated to get a Practical Lower Detection Limit that is not timed consuming for the analyst. It is presented using an example and, additionally its benefits are discussed versus the unattainable values that are obtained by the traditional use of the standard deviation of a series of measurements of the compound at concentrations near zero, which is then multiplied by the t student for a one tailed test for n-1 degrees of freedom

  19. The Use and Abuse of Limits of Detection in Environmental Analytical Chemistry

    Directory of Open Access Journals (Sweden)

    Richard J. C. Brown

    2008-01-01

    Full Text Available The limit of detection (LoD serves as an important method performance measure that is useful for the comparison of measurement techniques and the assessment of likely signal to noise performance, especially in environmental analytical chemistry. However, the LoD is only truly related to the precision characteristics of the analytical instrument employed for the analysis and the content of analyte in the blank sample. This article discusses how other criteria, such as sampling volume, can serve to distort the quoted LoD artificially and make comparison between various analytical methods inequitable. In order to compare LoDs between methods properly, it is necessary to state clearly all of the input parameters relating to the measurements that have been used in the calculation of the LoD. Additionally, the article discusses that the use of LoDs in contexts other than the comparison of the attributes of analytical methods, in particular when reporting analytical results, may be confusing, less informative than quoting the actual result with an accompanying statement of uncertainty, and may act to bias descriptive statistics.

  20. Improved detection limits for phthalates by selective solid-phase micro-extraction

    KAUST Repository

    Zia, Asif I.

    2016-03-30

    Presented research reports on an improved method and enhanced limits of detection for phthalates; a hazardous additive used in the production of plastics by solid-phase micro-extraction (SPME) polymer in comparison to molecularly imprinted solid-phase extraction (MISPE) polymer. The polymers were functionalized on an interdigital capacitive sensor for selective binding of phthalate molecules from a complex mixture of chemicals. Both polymers owned predetermined selectivity by formation of valuable molecular recognition sites for Bis (2-ethylhexyl) phthalate (DEHP). Polymers were immobilized on planar electrochemical sensor fabricated on a single crystal silicon substrate with 500 nm sputtered gold electrodes fabricated using MEMS fabrication techniques. Impedance spectra were obtained using electrochemical impedance spectroscopy (EIS) to determine sample conductance for evaluation of phthalate concentration in the spiked sample solutions with various phthalate concentrations. Experimental results revealed that the ability of SPME polymer to adsorb target molecules on the sensing surface is better than that of MISPE polymer for phthalates in the sensing system. Testing the extracted samples using high performance liquid chromatography with photodiode array detectors validated the results.

  1. On the limitations introduced by energy spread in elastic recoil detection analysis

    International Nuclear Information System (INIS)

    Szilagyi, E.

    2001-01-01

    Improvements in experimental techniques have led to monolayer depth resolution in heavy ion elastic recoil detection analysis (HI-ERDA). Evaluation of the spectra, however, is not trivial. The spectra, using even the best experimental set-up, are subject to finite energy resolution of both extrinsic and intrinsic origin. A proper account for energy spread is necessary to extract the correct depth profile from the measured spectra. With calculation of the correct energy (or depth) resolution of a given method, one can decide in advance whether or not the method will resolve details of interest in the depth profile. To achieve the best depth resolution, it is also possible to find optimum parameters for the experiments. The limitations introduced by the energy spread effects are discussed. An example for simulation is shown for high energy resolution HI-ERDA measurements. Satisfactory agreement between the simulated and the measured HI-ERDA spectra taken by 60 MeV 127 I 23+ ions on highly oriented pyrolythic graphite (HOPG) sample is found, in spite of the non-equilibrium charge state of the recoils and the difference in the stopping powers caused by the given charge state of the incident ion and the recoil, which are not taken into account. To achieve more precise data evaluation these effects should be included in simulation codes, or all the subspectra corresponding to different recoils charge states should be measured and summed

  2. On the limitations introduced by energy spread in elastic recoil detection analysis

    Energy Technology Data Exchange (ETDEWEB)

    Szilagyi, E. E-mail: szilagyi@rmki.kfki.hu

    2001-07-01

    Improvements in experimental techniques have led to monolayer depth resolution in heavy ion elastic recoil detection analysis (HI-ERDA). Evaluation of the spectra, however, is not trivial. The spectra, using even the best experimental set-up, are subject to finite energy resolution of both extrinsic and intrinsic origin. A proper account for energy spread is necessary to extract the correct depth profile from the measured spectra. With calculation of the correct energy (or depth) resolution of a given method, one can decide in advance whether or not the method will resolve details of interest in the depth profile. To achieve the best depth resolution, it is also possible to find optimum parameters for the experiments. The limitations introduced by the energy spread effects are discussed. An example for simulation is shown for high energy resolution HI-ERDA measurements. Satisfactory agreement between the simulated and the measured HI-ERDA spectra taken by 60 MeV {sup 127}I{sup 23+} ions on highly oriented pyrolythic graphite (HOPG) sample is found, in spite of the non-equilibrium charge state of the recoils and the difference in the stopping powers caused by the given charge state of the incident ion and the recoil, which are not taken into account. To achieve more precise data evaluation these effects should be included in simulation codes, or all the subspectra corresponding to different recoils charge states should be measured and summed.

  3. Direct Detection Electron Energy-Loss Spectroscopy: A Method to Push the Limits of Resolution and Sensitivity.

    Science.gov (United States)

    Hart, James L; Lang, Andrew C; Leff, Asher C; Longo, Paolo; Trevor, Colin; Twesten, Ray D; Taheri, Mitra L

    2017-08-15

    In many cases, electron counting with direct detection sensors offers improved resolution, lower noise, and higher pixel density compared to conventional, indirect detection sensors for electron microscopy applications. Direct detection technology has previously been utilized, with great success, for imaging and diffraction, but potential advantages for spectroscopy remain unexplored. Here we compare the performance of a direct detection sensor operated in counting mode and an indirect detection sensor (scintillator/fiber-optic/CCD) for electron energy-loss spectroscopy. Clear improvements in measured detective quantum efficiency and combined energy resolution/energy field-of-view are offered by counting mode direct detection, showing promise for efficient spectrum imaging, low-dose mapping of beam-sensitive specimens, trace element analysis, and time-resolved spectroscopy. Despite the limited counting rate imposed by the readout electronics, we show that both core-loss and low-loss spectral acquisition are practical. These developments will benefit biologists, chemists, physicists, and materials scientists alike.

  4. Compact quantum dot-antibody conjugates for FRET immunoassays with subnanomolar detection limits

    Science.gov (United States)

    Mattera, Lucia; Bhuckory, Shashi; Wegner, K. David; Qiu, Xue; Agnese, Fabio; Lincheneau, Christophe; Senden, Tim; Djurado, David; Charbonnière, Loïc J.; Hildebrandt, Niko; Reiss, Peter

    2016-05-01

    A novel two-step approach for quantum dot (QD) functionalization and bioconjugation is presented, which yields ultra-compact, stable, and highly luminescent antibody-QD conjugates suitable for use in FRET immunoassays. Hydrophobic InPZnS/ZnSe/ZnS (emission wavelength: 530 nm), CdSe/ZnS (605 nm), and CdSeTe/ZnS (705 nm) QDs were surface functionalized with zwitterionic penicillamine, enabling aqueous phase transfer under conservation of the photoluminescence properties. Post-functionalization with a heterobifunctional crosslinker, containing a lipoic acid group and a maleimide function, enabled the subsequent coupling to sulfhydryl groups of proteins. This was demonstrated by QD conjugation with fragmented antibodies (F(ab)). The obtained F(ab)-QD conjugates range among the smallest antibody-functionalized nanoprobes ever reported, with a hydrodynamic diameter coating for FRET could be demonstrated by an 6.2 and 2.5 fold improvement of the limit of detection (LOD) for PSA compared to commercially available hydrophilic QDs emitting at 605 and 705 nm, respectively. While the commercial QDs contain identical inorganic cores responsible for their fluorescence, they are coated with a comparably thick amphiphilic polymer layer leading to much larger hydrodynamic diameters (>26 nm without biomolecules). The LODs of 0.8 and 3.7 ng mL-1 obtained in 50 μL serum samples are below the clinical cut-off level of PSA (4 ng mL-1) and demonstrate their direct applicability in clinical diagnostics.A novel two-step approach for quantum dot (QD) functionalization and bioconjugation is presented, which yields ultra-compact, stable, and highly luminescent antibody-QD conjugates suitable for use in FRET immunoassays. Hydrophobic InPZnS/ZnSe/ZnS (emission wavelength: 530 nm), CdSe/ZnS (605 nm), and CdSeTe/ZnS (705 nm) QDs were surface functionalized with zwitterionic penicillamine, enabling aqueous phase transfer under conservation of the photoluminescence properties. Post

  5. Detection methods for legionellae. Possibilities and limitations of detection methods; Niet alle detectiemethoden geschikt voor legionellagroei. Mogelijkheden en beperkingen detectiemethoden

    Energy Technology Data Exchange (ETDEWEB)

    Scheffer, W.

    2011-06-15

    This article provides an overview of existing and new methods for detecting legionella in water. It offers insight in the characteristics and applications of existing and new detection methods. However, it is impossible to assess the value of alternative methods at the moment. That will require additional research. [Dutch] Een overzicht is gemaakt van bestaande en nieuwe methoden om legionella in water aan te tonen. Daarmee wordt inzicht verkregen in de kenmerken en toepassingsmogelijkheden van bestaande en nieuwe detectiemethoden. De waarde van alternatieve methoden in een installatie kan echter nog niet worden beoordeeld. Daarvoor is nader onderzoek nodig.

  6. A program for the a priori evaluation of detection limits in instrumental neutron activation analysis using a SLOWPOKE II reactor

    International Nuclear Information System (INIS)

    Galinier, J.L.; Zikovsky, L.

    1982-01-01

    A program that permits the a priori calculation of detection limits in monoelemental matrices, adapted to instrumental neutron activation analysis using a SLOWPOKE II reactor, is described. A simplified model of the gamma spectra is proposed. Products of (n,p) and (n,α) reactions induced by the fast components of the neutron flux that accompanies the thermal flux at the level of internal irradiation sites in the reactor have been included in the list of interfering radionuclides. The program calculates in a systematic way the detection limits of 66 elements in an equal number of matrices using 153 intermediary radionuclides. Experimental checks carried out with silicon (for short lifetimes) and aluminum and magnesium (for intermediate lifetimes) show satisfactory agreement with the calculations. These results show in particular the importance of the contribution of the (n,p) and (n,α) reactions in the a priori evaluation of detection limits with a SLOWPOKE type reactor [fr

  7. Minimum Wages and Poverty

    OpenAIRE

    Fields, Gary S.; Kanbur, Ravi

    2005-01-01

    Textbook analysis tells us that in a competitive labor market, the introduction of a minimum wage above the competitive equilibrium wage will cause unemployment. This paper makes two contributions to the basic theory of the minimum wage. First, we analyze the effects of a higher minimum wage in terms of poverty rather than in terms of unemployment. Second, we extend the standard textbook model to allow for incomesharing between the employed and the unemployed. We find that there are situation...

  8. Detection limits should be a thing of the past in gamma-ray spectrometry in general as well as in neutron activation analysis

    NARCIS (Netherlands)

    Blaauw, Menno

    2016-01-01

    In gamma-ray spectrometry with high-resolution detectors, full-energy peaks are often to be detected by a peak-search algorithm, with a threshold for detection. Detection limits can be derived from this. Detection limits are often computed along with measured activities or concentrations. When an

  9. Geodesy cannot presently detect the up-dip limit of frictional locking on megathrusts

    Science.gov (United States)

    Almeida, R. V.; Lindsey, E. O.; Bradley, K.; Hubbard, J.; Sathiakumar, S.; Malick, R.; Hill, E.

    2017-12-01

    Most discussions of interseismic behavior on megathrust faults focus on whether they are frictionally locked or creeping. Unfortunately, many geodetic studies of subduction zone megathrusts equate fault coupling with frictional locking. This comparison is not appropriate, as one reflects the physical properties of the fault, and the other reflects the kinematics of the fault. Much of the uncertainty about slip behavior is because in subduction zones, the shallow part of the fault is far from land, and therefore creep is not detectable by land-based GPS. Published coupling maps of subduction zone megathrusts often assume a low coupling ratio near the trench, updip from fully coupled regions. Yet, if the megathrust attains a coupling ratio of 1 anywhere on the fault (i.e., the hanging wall is moving with the same velocity as the footwall), a lower value of coupling updip of this location requires interseismic extension at a rate proportional to the decrease (Wang and Dixon, 2004). We argue that the shallow region of megathrusts lie in updip stress shadows, and do not (except under rare circumstances) experience appropriate driving forces to cause significant creep during the interseismic period. Therefore it may not be possible to determine whether these regions are frictionally locked by examining interseismic geodetic records. We demonstrate this effect using a boundary element model with rate-strengthening friction and a simplified subduction zone geometry. We show that a coupling value of zero at the trench is physically unrealistic even if only a small portion of the downdip fault zone is locked. The maximum creep at the trench depends on the width of the transition of the frictionally locked zone, but should be small (<30% of plate rate) under most circumstances. During the interseismic period, even if the shallow parts of megathrusts are frictionally unlocked, creep is likely smaller than the resolution of current seafloor geodetic techniques (which is

  10. Fabrication of Stretchable Copper Coated Carbon Nanotube Conductor for Non-Enzymatic Glucose Detection Electrode with Low Detection Limit and Selectivity

    Directory of Open Access Journals (Sweden)

    Dawei Jiang

    2018-03-01

    Full Text Available The increasing demand for wearable glucose sensing has stimulated growing interest in stretchable electrodes. The development of the electrode materials having large stretchability, low detection limit, and good selectivity is the key component for constructing high performance wearable glucose sensors. In this work, we presented fabrication of stretchable conductor based on the copper coated carbon nanotube sheath-core fiber, and its application as non-enzymatic electrode for glucose detection with high stretchability, low detection limit, and selectivity. The sheath-core fiber was fabricated by coating copper coated carbon nanotube on a pre-stretched rubber fiber core followed by release of pre-stretch, which had a hierarchically buckled structure. It showed a small resistance change as low as 27% as strain increasing from 0% to 500% strain, and a low resistance of 0.4 Ω·cm−1 at strain of 500%. This electrode showed linear glucose concentration detection in the range between 0.05 mM and 5 mM and good selectivity against sucrose, lactic acid, uric acid, acrylic acid in phosphate buffer saline solution, and showed stable signal in high salt concentration. The limit of detection (LOD was 0.05 mM, for the range of 0.05–5 mM, the sensitivity is 46 mA·M−1. This electrode can withstand large strain of up to 60% with negligible influence on its performance.

  11. Rapid Methods for the Detection of Foodborne Bacterial Pathogens: Principles, Applications, Advantages and Limitations

    Directory of Open Access Journals (Sweden)

    Law eJodi Woan-Fei

    2015-01-01

    Full Text Available The incidence of foodborne diseases has increased over the years and resulted in major public health problem globally. Foodborne pathogens can be found in various foods and it is important to detect foodborne pathogens to provide safe food supply and to prevent foodborne diseases. The conventional methods used to detect foodborne pathogen are time consuming and laborious. Hence, a variety of methods have been developed for rapid detection of foodborne pathogens as it is required in many food analyses. Rapid detection methods can be categorized into nucleic acid-based, biosensor-based and immunological-based methods. This review emphasizes on the principles and application of recent rapid methods for the detection of foodborne bacterial pathogens. Detection methods included are simple polymerase chain reaction (PCR, multiplex PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA, loop-mediated isothermal amplification (LAMP and oligonucleotide DNA microarray which classified as nucleic acid-based methods; optical, electrochemical and mass-based biosensors which classified as biosensor-based methods; enzyme-linked immunosorbent assay (ELISA and lateral flow immunoassay which classified as immunological-based methods. In general, rapid detection methods are generally time-efficient, sensitive, specific and labor-saving. The developments of rapid detection methods are vital in prevention and treatment of foodborne diseases.

  12. Current methods of handling less-than-detectable measurements and detection limits in statistical analysis of environmental data

    International Nuclear Information System (INIS)

    Hertzler, C.L.; Atwood, C.L.; Harris, G.A.

    1989-09-01

    A search was made of statistical literature that might be applicable in environmental assessment contexts, when some of the measured quantities are reported as less than detectable (LTD). Over 60 documents were reviewed, and the findings are described in this report. The methodological areas considered are parameter estimation (point estimates and confidence intervals), tolerance intervals and prediction intervals, regression, trend analysis, comparisons of populations (including two-sample comparisons and analysis of variance), and goodness of fit tests. The conclusions are summarized at the end of the report. 68 refs., 1 tab

  13. Evaluation of the limits of visual detection of image misregistration in a brain fluorine-18 fluorodeoxyglucose PET-MRI study

    International Nuclear Information System (INIS)

    Wong, J.C.H.; Studholme, C.; Hawkes, D.J.; Maisey, M.N.

    1997-01-01

    In routine clinical work, registration accuracy is assessed by visual inspection. However, the accuracy of visual assessment of registration has not been evaluated. This study establishes the limits of visual detection of misregistration in a registered brain fluorine-18 fluorodeoxyglucose positron emission tomography to magnetic resonance image volume. The ''best'' registered image volume was obtained by automatic registration using mutual information optimization. Translational movements by 1 mm, 2 mm, 3 mm and 4 mm, and rotational movements by 1 , 2 , 3 and 4 in the positive and negative directions in the x- (lateral), y- (anterior-posterior) and z- (axial) axes were introduced to this standard. These 48 images plus six ''best'' registered images were presented in random sequence to five observers for visual categorization of registration accuracy. No observer detected a definite misregistration in the ''best'' registered image. Evaluation for inter-observer variation using observer pairings showed a high percentage of agreement in assigned categories for both translational and rotational misregistrations. Assessment of the limits of detection of misregistration showed that a 2-mm translational misregistration was detectable by all observers in the x- and y-axes and 3-mm translational misregistration in the z-axis. With rotational misregistrations, rotation around the z-axis was detectable by all at 2 rotation whereas rotation around the y-axis was detected at 3-4 . Rotation around the x-axis was not symmetric with a positive rotation being identified at 2 whereas negative rotation was detected by all only at 4 . Therefore, visual analysis appears to be a sensitive and practical means to assess image misregistration accuracy. The awareness of the limits of visual detection of misregistration will lead to increase care when evaluating registration quality in both research and clinical settings. (orig.). With 6 figs., 3 tabs

  14. Detection and quantification limits: basic concepts, international harmonization, and outstanding ('low-level') issues

    International Nuclear Information System (INIS)

    Currie, L.A.

    2004-01-01

    A brief review is given of concepts, basic definitions, and terminology for metrological detection and quantification capabilities, representing harmonized recommendations and norms of the International Union of Pure and Applied Chemistry (IUPAC) and the International Organization for Standardization (ISO), respectively. Treatment of the (low-level) blank and variance function are discussed in some detail, together with special problems arising with detection decisions and the reporting of low-level data. Key references to the international documents follow, as well as specialized references addressing very low-level counting data, skewed environmental blank distributions, and multiple and multivariate detection decisions

  15. The detection and stabilisation of limit cycle for deterministic finite automata

    Science.gov (United States)

    Han, Xiaoguang; Chen, Zengqiang; Liu, Zhongxin; Zhang, Qing

    2018-04-01

    In this paper, the topological structure properties of deterministic finite automata (DFA), under the framework of the semi-tensor product of matrices, are investigated. First, the dynamics of DFA are converted into a new algebraic form as a discrete-time linear system by means of Boolean algebra. Using this algebraic description, the approach of calculating the limit cycles of different lengths is given. Second, we present two fundamental concepts, namely, domain of attraction of limit cycle and prereachability set. Based on the prereachability set, an explicit solution of calculating domain of attraction of a limit cycle is completely characterised. Third, we define the globally attractive limit cycle, and then the necessary and sufficient condition for verifying whether all state trajectories of a DFA enter a given limit cycle in a finite number of transitions is given. Fourth, the problem of whether a DFA can be stabilised to a limit cycle by the state feedback controller is discussed. Criteria for limit cycle-stabilisation are established. All state feedback controllers which implement the minimal length trajectories from each state to the limit cycle are obtained by using the proposed algorithm. Finally, an illustrative example is presented to show the theoretical results.

  16. DNA isolation protocols affect the detection limit of PCR approaches of bacteria in samples from the human gastrointestinal tract

    NARCIS (Netherlands)

    Zoetendal, E.G.; Ben-Amor, K.; Akkermans, A.D.L.; Abee, T.; Vos, de W.M.

    2001-01-01

    A major concern in molecular ecological studies is the lysis efficiency of different bacteria in a complex ecosystem. We used a PCR-based 16S rDNA approach to determine the effect of two DNA isolation protocols (i.e. the bead beating and Triton-X100 method) on the detection limit of seven

  17. Re-evaluation of groundwater monitoring data for glyphosate and bentazone by taking detection limits into account

    DEFF Research Database (Denmark)

    Hansen, Claus Toni; Ritz, Christian; Gerhard, Daniel

    2015-01-01

    .e. samples with concentrations below the detection limit, as left-censored observations. The median calculated pesticide concentrations are shown to be reduced 10(4) to 10(5) fold for two representative herbicides (glyphosate and bentazone) relative to the median concentrations based upon observations above...

  18. Analysis of uncertainties and detection limits for the double measurement method of {sup 90}Sr and {sup 89}Sr

    Energy Technology Data Exchange (ETDEWEB)

    Herranz, M., E-mail: m.herranz@ehu.es [Department of Nuclear Engineering and Fluid Mechanics, University of the Basque Country (UPV/EHU), Alameda de Urquijo s/n 48013 Bilbao (Spain); Idoeta, R.; Legarda, F. [Department of Nuclear Engineering and Fluid Mechanics, University of the Basque Country (UPV/EHU), Alameda de Urquijo s/n 48013 Bilbao (Spain)

    2011-08-15

    The determination process of the {sup 90}Sr and {sup 89}Sr contents in a sample, although it involves their radiochemical isolation, results always in a complex measurement process due to the interferences among their respective beta emissions and also among those of the daughter of {sup 90}Sr, {sup 90}Y, a beta emitter as well. In this paper, the process consisting in a double measurement method after the Sr radiochemical isolation is analyzed, developing the formulae to obtain activity concentrations, uncertainties and detection limits. A study of the trend of uncertainties and detection limits as function of the time in which the first measurement since the isolation is done, the delay between the two measurements and the activity concentration of each strontium isotope in the sample is carried out as well. Results show that with a very precise determination of the times involved in the whole process (isolation, measurement and duration of measurements) this method permits a reliable assessment of both strontium radioisotopes. The quicker the first measurement since the isolation is done and the longer the delay between measurements is chosen, the lower are the detection limits and the uncertainties of the activities obtained. - Highlights: > The double measurement method for {sup 90}Sr and {sup 89}Sr determination is analysed. > Uncertainties and detection limits are determined and their dependences studied. > Proposals for the optimization of the method are given.

  19. 40 CFR Appendix C to Part 425 - Definition and Procedure for the Determination of the Method Detection Limit 1

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 29 2010-07-01 2010-07-01 false Definition and Procedure for the Determination of the Method Detection Limit 1 C Appendix C to Part 425 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS LEATHER TANNING AND FINISHING POINT SOURCE...

  20. Consistent Practices for Characterizing the Detection Limits of Fracture Critical Metallic Component Inspection Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA-STD-5009 requires that successful flaw detection by NDE methods be statistically qualified for use on fracture critical metallic components using Probability of...

  1. Limitations and Strengths of the Fourier Transform Method to Detect Accelerating Targets

    National Research Council Canada - National Science Library

    Thayaparan, Thayananthan

    2000-01-01

    .... In using a Pulse Doppler Radar to detect a non-accelerating target in additive white Gaussian noise and to estimate its radial velocity, the Fourier method provides an output signal-to-noise ratio (SNR...

  2. Rapid Detection Strategies for the Global Threat of Zika Virus: Current State, New Hypotheses and Limitations

    Directory of Open Access Journals (Sweden)

    Shruti Shukla

    2016-10-01

    Full Text Available The current scenario regarding the widespread Zika virus (ZIKV has resulted in numerous diagnostic studies, specifically in South America and in locations where there is frequent entry of travelers returning from ZIKV-affected areas, including pregnant women with or without clinical symptoms of ZIKV infection. The World Health Organization, WHO, announced that millions of cases of ZIKV are likely to occur in the United States of America in the near future. This situation has created an alarming public health emergency of international concern requiring the detection of this life-threatening viral candidate due to increased cases of newborn microcephaly associated with ZIKV infection. Hence, this review reports possible methods and strategies for the fast and reliable detection of ZIKV with particular emphasis on current updates, knowledge and new hypotheses that might be helpful for medical professionals in poor and developing countries that urgently need to address this problem. In particular, we emphasize liposome-based biosensors. Although these biosensors are currently among the less popular tools for human disease detection, they have become useful tools for the screening and detection of pathogenic bacteria, fungi and viruses because of their versatile advantageous features compared to other sensing devices. This review summarizes the currently available methods employed for the rapid detection of ZIKV and suggests an innovative approach involving the application of a liposome-based hypothesis for the development of new strategies for ZIKV detection and their use as effective biomedicinal tools.

  3. Limit of detection for the determination of Pt in biological material by RNAA using electrolytic separation of gold

    International Nuclear Information System (INIS)

    Xilei, L.; Heydorn, K.; Rietz, B.

    1992-01-01

    Neutron activation analysis based on the 199 Au indicator for platinum requires the separation of gold at high radiochemical purity. The limit of detection is strongly affected by the presence of gold; with a gold content of 50 pg/g, irradiating for 5 days at 5*10 13 n/cm 2 is needed to achieve a limit of detection of approximately 30 pg/g. In this case the nuclear interference from gold will exceeded the level of platium by several orders of magnitude and has to be determined with exceedingly high precision. Preliminary results for SRM 1577 Bovine Liver with 95% yield gave consistent results for Au, but Pt could not be detected. (author) 23 refs.; 3 figs.; 4 tabs

  4. Limits on surface gravities of Kepler planet-candidate host stars from non-detection of solar-like oscillations

    Energy Technology Data Exchange (ETDEWEB)

    Campante, T. L.; Chaplin, W. J.; Handberg, R.; Miglio, A.; Davies, G. R.; Elsworth, Y. P. [School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Lund, M. N.; Arentoft, T.; Christensen-Dalsgaard, J.; Karoff, C.; Kjeldsen, H.; Lundkvist, M. [Stellar Astrophysics Centre (SAC), Department of Physics and Astronomy, Aarhus University, Ny Munkegade 120, DK-8000 Aarhus C (Denmark); Huber, D. [NASA Ames Research Center, MS 244-30, Moffett Field, CA 94035 (United States); Hekker, S. [Astronomical Institute, " Anton Pannekoek," University of Amsterdam, Amsterdam (Netherlands); García, R. A. [Laboratoire AIM, CEA/DSM-CNRS-Université Paris Diderot (France); IRFU/SAp, Centre de Saclay, F-91191 Gif-sur-Yvette Cedex (France); Corsaro, E. [Instituut voor Sterrenkunde, KU Leuven, Celestijnenlaan 200D, B-3001 Leuven (Belgium); Basu, S. [Department of Astronomy, Yale University, New Haven, CT 06520 (United States); Bedding, T. R. [Sydney Institute for Astronomy, School of Physics, University of Sydney, Sydney (Australia); Gilliland, R. L. [Center for Exoplanets and Habitable Worlds, The Pennsylvania State University, University Park, PA 16802 (United States); Kawaler, S. D., E-mail: campante@bison.ph.bham.ac.uk [Department of Physics and Astronomy, Iowa State University, Ames, IA 50011 (United States); and others

    2014-03-10

    We present a novel method for estimating lower-limit surface gravities (log g) of Kepler targets whose data do not allow the detection of solar-like oscillations. The method is tested using an ensemble of solar-type stars observed in the context of the Kepler Asteroseismic Science Consortium. We then proceed to estimate lower-limit log g for a cohort of Kepler solar-type planet-candidate host stars with no detected oscillations. Limits on fundamental stellar properties, as provided by this work, are likely to be useful in the characterization of the corresponding candidate planetary systems. Furthermore, an important byproduct of the current work is the confirmation that amplitudes of solar-like oscillations are suppressed in stars with increased levels of surface magnetic activity.

  5. Minimum critical mass systems

    International Nuclear Information System (INIS)

    Dam, H. van; Leege, P.F.A. de

    1987-01-01

    An analysis is presented of thermal systems with minimum critical mass, based on the use of materials with optimum neutron moderating and reflecting properties. The optimum fissile material distributions in the systems are obtained by calculations with standard computer codes, extended with a routine for flat fuel importance search. It is shown that in the minimum critical mass configuration a considerable part of the fuel is positioned in the reflector region. For 239 Pu a minimum critical mass of 87 g is found, which is the lowest value reported hitherto. (author)

  6. Detection of bacteria based on the thermomechanical noise of a nanomechanical resonator: origin of the response and detection limits

    International Nuclear Information System (INIS)

    Ramos, D; Tamayo, J; Mertens, J; Calleja, M; Villanueva, L G; Zaballos, A

    2008-01-01

    We have measured the effect of bacteria adsorption on the resonant frequency of microcantilevers as a function of the adsorption position and vibration mode. The resonant frequencies were measured from the Brownian fluctuations of the cantilever tip. We found that the sign and amount of the resonant frequency change is determined by the position and extent of the adsorption on the cantilever with regard to the shape of the vibration mode. To explain these results, a theoretical one-dimensional model is proposed. We obtain analytical expressions for the resonant frequency that accurately fit the data obtained by the finite element method. More importantly, the theory data shows a good agreement with the experiments. Our results indicate that there exist two opposite mechanisms that can produce a significant resonant frequency shift: the stiffness and the mass of the bacterial cells. Based on the thermomechanical noise, we analyse the regions of the cantilever of lowest and highest sensitivity to the attachment of bacteria. The combination of high vibration modes and the confinement of the adsorption to defined regions of the cantilever allows the detection of single bacterial cells by only measuring the Brownian fluctuations. This study can be extended to smaller cantilevers and other biological systems such as proteins and nucleic acids

  7. The physics of detecting torsion and placing limits on its effects

    International Nuclear Information System (INIS)

    Stoeger, W.R.

    1985-01-01

    The essential principles of torsion-detection physics are presented and several conceivable types of experiments and observations for actually detecting torsion fields are evaluated reemphasizing also the evident impossibility of successfully searching for its manifestations among cosmological relics. In particular, a polarized body, with net intrinsic (fundamental-particle) spin, is essential for detecting a torsion field. One which possesses only orbital angular momentum-rotation-or an unpolarized intrinsic spin density will not feel torsion. The fundamental problem in searching for such fields is the extremely small basic unit of the coupling or interaction energy between the torsion field and spin, epsilonapprox.(8πG'/c 2 )(h 2 /4). The best way of maximizing the total interaction energy is to increase the spin density of the source σ 5 and, at the same time the ''spin number'' Ssub(D) of the detector. (author)

  8. Limitations to depth resolution in high-energy, heavy-ion elastic recoil detection analysis

    International Nuclear Information System (INIS)

    Elliman, R.G.; Palmer, G.R.; Ophel, T.R.; Timmers, H.

    1998-01-01

    The depth resolution of heavy-ion elastic recoil detection analysis was examined for Al and Co thin films ranging in thickness from 100 to 400 nm. Measurements were performed with 154 MeV Au ions as the incident beam, and recoils were detected using a gas ionisation detector. Energy spectra were extracted for the Al and Co recoils and the depth resolution determined as a function of film thickness from the width of the high- and low- energy edges. These results were compared with theoretical estimates calculated using the computer program DEPTH. (authors)

  9. Environmental distributions and the practical utilisation of detection limited environment measurement data

    International Nuclear Information System (INIS)

    Daniels, W.M.; Higgins, N.A.

    2002-01-01

    This study investigated methods of providing summary statistics for measurements of radioactive contamination in food when the available measurements are incomplete. Several techniques to calculate, for instance, the mean level of contamination when a significant number of samples are found to have less than the minimum level reported by measurements, are discussed. To support the estimation of summary statistics the study identifies physical processes that give rise to observed distributions, eg lognormal for the range of radioactivity levels found in environmental and food samples. The improved estimates possible by application of the methods reviewed will allow the Food Standards Agency to gain a better understanding of the levels of radioactivity in the environment and if required direct effort to minimising the most significant uncertainties in these estimates. The Ministry of Agriculture, Fisheries and Food, Radiological Safety and Nutrition Division (now part of the Food Standards Agency) funded this study, under contract RP0342. This work was undertaken under the Environmental Assessments and Emergency Response Group's Quality Management System, which has been approved by Lloyd's Register Quality Assurance to the Quality Management Standards ISO 9001:2000 and TickIT Guide Issue 5, certificate number 956546. (author)

  10. Minimum entropy production principle

    Czech Academy of Sciences Publication Activity Database

    Maes, C.; Netočný, Karel

    2013-01-01

    Roč. 8, č. 7 (2013), s. 9664-9677 ISSN 1941-6016 Institutional support: RVO:68378271 Keywords : MINEP Subject RIV: BE - Theoretical Physics http://www.scholarpedia.org/article/Minimum_entropy_production_principle

  11. Minimum resolvable power contrast model

    Science.gov (United States)

    Qian, Shuai; Wang, Xia; Zhou, Jingjing

    2018-01-01

    Signal-to-noise ratio and MTF are important indexs to evaluate the performance of optical systems. However,whether they are used alone or joint assessment cannot intuitively describe the overall performance of the system. Therefore, an index is proposed to reflect the comprehensive system performance-Minimum Resolvable Radiation Performance Contrast (MRP) model. MRP is an evaluation model without human eyes. It starts from the radiance of the target and the background, transforms the target and background into the equivalent strips,and considers attenuation of the atmosphere, the optical imaging system, and the detector. Combining with the signal-to-noise ratio and the MTF, the Minimum Resolvable Radiation Performance Contrast is obtained. Finally the detection probability model of MRP is given.

  12. Limited evidence for the use of imaging to detect prostate cancer: A systematic review

    International Nuclear Information System (INIS)

    Blomqvist, L.; Carlsson, S.; Gjertsson, P.; Heintz, E.; Hultcrantz, M.; Mejare, I.; Andrén, O.

    2014-01-01

    Highlights: • In men with clinical suspicion of prostate cancer, ultrasound guided systematic biopsies is the golden standard for diagnosis. • Diagnostic imaging techniques, especially magnetic resonance imaging, is being used in trials to aid detection of prostate cancer. • To date, there is insufficient scientific evidence for the use of imaging techniques to detect prostate cancer. - Abstract: Objective: To assess the diagnostic accuracy of imaging technologies for detecting prostate cancer in patients with elevated PSA-values or suspected findings on clinical examination. Methods: The databases Medline, EMBASE, Cochrane, CRD HTA/DARE/NHS EED and EconLit were searched until June 2013. Pre-determined inclusion criteria were used to select full text articles. Risk of bias in individual studies was rated according to QUADAS or AMSTAR. Abstracts and full text articles were assessed independently by two reviewers. The performance of diagnostic imaging was compared with systematic biopsies (reference standard) and sensitivity and specificity were calculated. Results: The literature search yielded 5141 abstracts, which were reviewed by two independent reviewers. Of these 4852 were excluded since they did not meet the inclusion criteria. 288 articles were reviewed in full text for quality assessment. Six studies, three using MRI and three using transrectal ultrasound were included. All were rated as high risk of bias. Relevant studies on PET/CT were not identified. Conclusion: Despite clinical use, there is insufficient evidence regarding the accuracy of imaging technologies for detecting cancer in patients with suspected prostate cancer using TRUS guided systematic biopsies as reference standard

  13. Limited evidence for the use of imaging to detect prostate cancer: A systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Blomqvist, L., E-mail: lennart.k.blomqvist@ki.se [Department of Diagnostic Radiology, Karolinska University Hospital, Solna (Sweden); Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm (Sweden); Carlsson, S. [Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm (Sweden); Department of Urology, Karolinska University Hospital, Solna (Sweden); Gjertsson, P. [Department of Clinical Physiology, Sahlgrenska University Hospital, Gothenburg (Sweden); Heintz, E.; Hultcrantz, M.; Mejare, I. [The Swedish Council on Health Technology Assessment, Stockholm (Sweden); Andrén, O. [School of Health and Medical Sciences, Örebro University, Örebro (Sweden); Department of Urology, Örebro University Hospital, Örebro (Sweden)

    2014-09-15

    Highlights: • In men with clinical suspicion of prostate cancer, ultrasound guided systematic biopsies is the golden standard for diagnosis. • Diagnostic imaging techniques, especially magnetic resonance imaging, is being used in trials to aid detection of prostate cancer. • To date, there is insufficient scientific evidence for the use of imaging techniques to detect prostate cancer. - Abstract: Objective: To assess the diagnostic accuracy of imaging technologies for detecting prostate cancer in patients with elevated PSA-values or suspected findings on clinical examination. Methods: The databases Medline, EMBASE, Cochrane, CRD HTA/DARE/NHS EED and EconLit were searched until June 2013. Pre-determined inclusion criteria were used to select full text articles. Risk of bias in individual studies was rated according to QUADAS or AMSTAR. Abstracts and full text articles were assessed independently by two reviewers. The performance of diagnostic imaging was compared with systematic biopsies (reference standard) and sensitivity and specificity were calculated. Results: The literature search yielded 5141 abstracts, which were reviewed by two independent reviewers. Of these 4852 were excluded since they did not meet the inclusion criteria. 288 articles were reviewed in full text for quality assessment. Six studies, three using MRI and three using transrectal ultrasound were included. All were rated as high risk of bias. Relevant studies on PET/CT were not identified. Conclusion: Despite clinical use, there is insufficient evidence regarding the accuracy of imaging technologies for detecting cancer in patients with suspected prostate cancer using TRUS guided systematic biopsies as reference standard.

  14. Detecting gravitational waves from precessing binaries of spinning compact objects: Adiabatic limit

    International Nuclear Information System (INIS)

    Buonanno, Alessandra; Chen Yanbei; Vallisneri, Michele

    2003-01-01

    Black-hole (BH) binaries with single-BH masses m=(5-20)M · , moving on quasicircular orbits, are among the most promising sources for first-generation ground-based gravitational-wave (GW) detectors. Until now, the development of data-analysis techniques to detect GWs from these sources has been focused mostly on nonspinning BHs. The data-analysis problem for the spinning case is complicated by the necessity to model the precession-induced modulations of the GW signal, and by the large number of parameters needed to characterize the system, including the initial directions of the spins, and the position and orientation of the binary with respect to the GW detector. In this paper we consider binaries of maximally spinning BHs, and we work in the adiabatic-inspiral regime to build families of modulated detection templates that (i) are functions of very few physical and phenomenological parameters, (ii) model remarkably well the dynamical and precessional effects on the GW signal, with fitting factors on average > or approx. 0.97, (iii) but, however, might require increasing the detection thresholds, offsetting at least partially the gains in the fitting factors. Our detection-template families are quite promising also for the case of neutron-star-black-hole binaries, with fitting factors on average ≅0.93. For these binaries we also suggest (but do not test) a further template family, which would produce essentially exact waveforms written directly in terms of the physical spin parameters

  15. Adaptive Framework for Classification and Novel Class Detection over Evolving Data Streams with Limited Labeled Data.

    Energy Technology Data Exchange (ETDEWEB)

    Haque, Ahsanul [Univ. of Texas, Dallas, TX (United States); Khan, Latifur [Univ. of Texas, Dallas, TX (United States); Baron, Michael [Univ. of Texas, Dallas, TX (United States); Ingram, Joey Burton [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    Most approaches to classifying evolving data streams either divide the stream of data into fixed-size chunks or use gradual forgetting to address the problems of infinite length and concept drift. Finding the fixed size of the chunks or choosing a forgetting rate without prior knowledge about time-scale of change is not a trivial task. As a result, these approaches suffer from a trade-off between performance and sensitivity. To address this problem, we present a framework which uses change detection techniques on the classifier performance to determine chunk boundaries dynamically. Though this framework exhibits good performance, it is heavily dependent on the availability of true labels of data instances. However, labeled data instances are scarce in realistic settings and not readily available. Therefore, we present a second framework which is unsupervised in nature, and exploits change detection on classifier confidence values to determine chunk boundaries dynamically. In this way, it avoids the use of labeled data while still addressing the problems of infinite length and concept drift. Moreover, both of our proposed frameworks address the concept evolution problem by detecting outliers having similar values for the attributes. We provide theoretical proof that our change detection method works better than other state-of-the-art approaches in this particular scenario. Results from experiments on various benchmark and synthetic data sets also show the efficiency of our proposed frameworks.

  16. Group-focused morality is associated with limited conflict detection and resolution capacity: Neuroanatomical evidence.

    Science.gov (United States)

    Nash, Kyle; Baumgartner, Thomas; Knoch, Daria

    2017-02-01

    Group-focused moral foundations (GMFs) - moral values that help protect the group's welfare - sharply divide conservatives from liberals and religiously devout from non-believers. However, there is little evidence about what drives this divide. Moral foundations theory and the model of motivated social cognition both associate group-focused moral foundations with differences in conflict detection and resolution capacity, but in opposing directions. Individual differences in conflict detection and resolution implicate specific neuroanatomical differences. Examining neuroanatomy thus affords an objective and non-biased opportunity to contrast these influential theories. Here, we report that increased adherence to group-focused moral foundations was strongly associated (whole-brain corrected) with reduced gray matter volume in key regions of the conflict detection and resolution system (anterior cingulate cortex and lateral prefrontal cortex). Because reduced gray matter is reliably associated with reduced neural and cognitive capacity, these findings support the idea outlined in the model of motivated social cognition that belief in group-focused moral values is associated with reduced conflict detection and resolution capacity. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Evaluation of a single-item screening question to detect limited health literacy in peritoneal dialysis patients.

    Science.gov (United States)

    Jain, Deepika; Sheth, Heena; Bender, Filitsa H; Weisbord, Steven D; Green, Jamie A

    2014-01-01

    Studies have shown that a single-item question might be useful in identifying patients with limited health literacy. However, the utility of the approach has not been studied in patients receiving maintenance peritoneal dialysis (PD). We assessed health literacy in a cohort of 31 PD patients by administering the Rapid Estimate of Adult Literacy in Medicine (REALM) and a single-item health literacy (SHL) screening question "How confident are you filling out medical forms by yourself?" (Extremely, Quite a bit, Somewhat, A little bit, or Not at all). To determine the accuracy of the single-item question for detecting limited health literacy, we performed sensitivity and specificity analyses of the SHL and plotted the area under the receiver operating characteristic (AUROC) curve using the REALM as a reference standard. Using a cut-off of "Somewhat" or less confident, the sensitivity of the SHL for detecting limited health literacy was 80%, and the specificity was 88%. The positive likelihood ratio was 6.9. The SHL had an AUROC of 0.79 (95% confidence interval: 0.52 to 1.00). Our results show that the SHL could be effective in detecting limited health literacy in PD patients.

  18. The value and limitations of contrast-enhanced transrectal ultrasonography for the detection of prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Han-Xue, E-mail: zhaohx861@163.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Xia, Chun-Xia, E-mail: star9901482@163.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Yin, Hong-Xia, E-mail: hongxia_yin79@yahoo.com.cn [Department of Radiology, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Guo, Ning, E-mail: ningguo99@sina.com.cn [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China); Zhu, Qiang, E-mail: qzhutrhos@gmail.com [Department of Diagnostic Ultrasound, Beijing Tongren Hospital, Capital Medical University, Dong-Jiao-Min-Xiang, Dong Cheng District, Beijing 100730 (China)

    2013-11-01

    Objectives: To evaluate the role of contrast-enhanced transrectal ultrasonography (CE-TRUS) for detecting prostate carcinoma. Methods: Sixty-five patients with elevated serum prostate-specific antigen (PSA) and/or abnormal digital rectal examination (DRE) were assessed using transrectal ultrasound (TRUS) and CE-TRUS. In all the patients, CE-TRUS was performed with intravenous injection of contrast agent (SonoVue, 2.4 ml) before biopsy. The cancer detection rates of the two techniques were compared. False-positive and false-negative findings related to CE-TRUS were analyzed in comparison to the pathological results of biopsy or radical prostatectomy. The targeted biopsy to abnormal CE-TRUS areas was also compared to systematic biopsy. Results: Prostate cancer was detected in 29 of the 65 patients. CE-TRUS showed rapid focal enhancement or asymmetric vessels of peripheral zones in 28 patients; 23 of them had prostate cancer. CE-TRUS had 79.3% sensitivity, compared to 65.5% of TRUS (P < 0.05). There were five false-positive and six false-negative findings from CE-TRUS. Benign prostate hyperplasia, and acute and chronic prostatitis were important causes related to the false-positive results of CE-TRUS. Prostate cancer originating from the transition zone or peripheral zone with lower PSA levels, small-size foci, and moderately or well-differentiated tumor was missed by CE-TRUS. The cancer detection rate of targeted biopsy (75%, 33/44 cores) was significantly higher than one of systematic biopsy (48.2%, 162/336) in those 28 cases (P < 0.05). In addition, no significant correlation was found between the cancer detection rate with CE-TRUS and serum PSA levels. Conclusion: CE-TRUS may improve the detection rate of prostate cancer through targeted biopsy of contrast-enhanced abnormalities. Our findings indicate that systematic biopsies should not be eliminated on the basis of false-positive and false-negative findings related to CE-TRUS.

  19. Lower limit of detection: definition and elaboration of a proposed position for radiological effluent and environmental measurements

    International Nuclear Information System (INIS)

    Currie, L.A.

    1984-09-01

    A manual is provided to define and illustrate a proposed use of the Lower Limit of Detection (LLD) for Radiological Effluent and Environmental Measurements. The manual contains a review of information regarding LLD practices gained from site visits; a review of the literature and a summary of basic principles underlying the concept of detection in Nuclear and Analytical Chemistry; a detailed presentation of the application of LLD principles to a range of problem categories (simple counting to multinuclide spectroscopy), including derivations, equations, and numerical examples; and a brief examination of related issues such as reference samples, numerical quality control, and instrumental limitations. An appendix contains a summary of notation and terminology, a bibliography, and worked-out examples. 100 references, 10 figures, 7 tables

  20. Detection limits in the chromatographic element trace analysis - quantitative TLC, HPLC and GC with the example of beryllium acetylacetonate

    International Nuclear Information System (INIS)

    Schwedt, G.

    1981-01-01

    Chromatographic analyses of beryllium acetylacetonate are carried out in synthetic solutions within the nano- and picogram range of beryllium. For thin-layer chromatography (TLC) normal and silanized silica gel is used, for high-performance liquid chromatography (HPLC) silica gel of 7 μm particles, for gas chromatography (GC) silicone SE-30 as stationary phase. Visual evaluation and remission measurements in TLC, UV-254 nm absorption measurements in HPLC and measurements with a FID in GC are employed for the determination of the calibration curves. A calibration curve through the origin and a detection limit of 150 pg Be determinable form are received by HPLC only. For trace analyses by GC a new definition of a detection limit for the evaluation of substance peaks on a solvent tailing is suggested. (orig.) [de

  1. Potentials and Limitations of Real-Time Elastography for Prostate Cancer Detection: A Whole-Mount Step Section Analysis

    Directory of Open Access Journals (Sweden)

    Daniel Junker

    2012-01-01

    Full Text Available Objectives. To evaluate prostate cancer (PCa detection rates of real-time elastography (RTE in dependence of tumor size, tumor volume, localization and histological type. Materials and Methods. Thirdy-nine patients with biopsy proven PCa underwent RTE before radical prostatectomy (RPE to assess prostate tissue elasticity, and hard lesions were considered suspicious for PCa. After RPE, the prostates were prepared as whole-mount step sections and were compared with imaging findings for analyzing PCa detection rates. Results. RTE detected 6/62 cancer lesions with a maximum diameter of 0–5 mm (9.7%, 10/37 with a maximum diameter of 6–10 mm (27%, 24/34 with a maximum diameter of 11–20 20 mm (70.6%, 14/14 with a maximum diameter of >20 mm (100% and 40/48 with a volume ≥0.2 cm3 (83.3%. Regarding cancer lesions with a volume ≥ 0.2 cm³ there was a significant difference in PCa detection rates between Gleason scores with predominant Gleason pattern 3 compared to those with predominant Gleason pattern 4 or 5 (75% versus 100%; P=0.028. Conclusions. RTE is able to detect PCa of significant tumor volume and of predominant Gleason pattern 4 or 5 with high confidence, but is of limited value in the detection of small cancer lesions.

  2. Sensitivities and detection limits of X-ray fluorescence analysis with a 10 mCi241Am source

    International Nuclear Information System (INIS)

    Wundt, K.; Janghorbani, M.; Starke, K.

    1976-01-01

    Seven trace elements ranging from chromium to barium were preconcentrated on Amberlite IR-120 cation exchange paper and determined in an energy dispersive X-ray fluorescence system using a 10 mCi 241 Am source. Sensitivities were experimentally determined and checked with theoretically calculated values. The detection limits are compared with elemental levels present in typical surface waters and those allowed in drinking water. Appropriate conclusions as to feasibility of such a system for environmental monitoring are drawn. (orig.) [de

  3. Improved sensitivity and limit-of-detection of lateral flow devices using spatial constrictions of the flow-path.

    Science.gov (United States)

    Katis, Ioannis N; He, Peijun J W; Eason, Robert W; Sones, Collin L

    2018-05-03

    We report on the use of a laser-direct write (LDW) technique that allows the fabrication of lateral flow devices with enhanced sensitivity and limit of detection. This manufacturing technique comprises the dispensing of a liquid photopolymer at specific regions of a nitrocellulose membrane and its subsequent photopolymerisation to create impermeable walls inside the volume of the membrane. These polymerised structures are intentionally designed to create fluidic channels which are constricted over a specific length that spans the test zone within which the sample interacts with pre-deposited reagents. Experiments were conducted to show how these constrictions alter the fluid flow rate and the test zone area within the constricted channel geometries. The slower flow rate and smaller test zone area result in the increased sensitivity and lowered limit of detection for these devices. We have quantified these via the improved performance of a C-Reactive Protein (CRP) sandwich assay on our lateral flow devices with constricted flow paths which demonstrate an improvement in its sensitivity by 62x and in its limit of detection by 30x when compared to a standard lateral flow CRP device. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  4. Detection Limits for Spectro-fluorometry: A Case Study in the Region of Finstersee, Canton Zug, Northern Switzerland

    Science.gov (United States)

    Otz, M. H.; Otz, H. K.; Keller, P.

    2002-05-01

    Synthetic fluorescent dyes, applied below the visual detection limit (< 0.1 mg/L), have been used as tracers of ground water flow paths since the beginning of the 1950s. Since 1965, we have used spectro-fluorometers with photomultipliers to measure low concentrations of fluorescent dyes in ground water in Switzerland. In collaboration with the Engineering Geology Department of the ETH, we have separated uranine at 0.1 ng/L and Na-naphtionate at 1 ng/L from background fluorescence of spring water in the Finstersee region. These values are 10-100 times lower than postulated detection limits in the literature. The use of low dye concentrations prevents a study region from being contaminated by increased background levels due to remnant dye within the aquifer, thereby leaving the region available for future dye tracing studies. Lower detection limits also can solve particular hydraulic problems where conventional methods fail and enhance the possibility for using artificial dyes in environmentally sensitive aquifer settings.

  5. Generalized linear mixed model for binary outcomes when covariates are subject to measurement errors and detection limits.

    Science.gov (United States)

    Xie, Xianhong; Xue, Xiaonan; Strickler, Howard D

    2018-01-15

    Longitudinal measurement of biomarkers is important in determining risk factors for binary endpoints such as infection or disease. However, biomarkers are subject to measurement error, and some are also subject to left-censoring due to a lower limit of detection. Statistical methods to address these issues are few. We herein propose a generalized linear mixed model and estimate the model parameters using the Monte Carlo Newton-Raphson (MCNR) method. Inferences regarding the parameters are made by applying Louis's method and the delta method. Simulation studies were conducted to compare the proposed MCNR method with existing methods including the maximum likelihood (ML) method and the ad hoc approach of replacing the left-censored values with half of the detection limit (HDL). The results showed that the performance of the MCNR method is superior to ML and HDL with respect to the empirical standard error, as well as the coverage probability for the 95% confidence interval. The HDL method uses an incorrect imputation method, and the computation is constrained by the number of quadrature points; while the ML method also suffers from the constrain for the number of quadrature points, the MCNR method does not have this limitation and approximates the likelihood function better than the other methods. The improvement of the MCNR method is further illustrated with real-world data from a longitudinal study of local cervicovaginal HIV viral load and its effects on oncogenic HPV detection in HIV-positive women. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Internal Dosimetry Monitoring- Detection Limits for a Selected Set of Radionuclides and Their Translation Into Committed Effective Dose

    International Nuclear Information System (INIS)

    Brandl, A.; Hrnecek, E.; Steger, F.

    2004-01-01

    To harmonize the practice of internal dosimetry monitoring across the country, the Austrian Standards Institute is currently drafting a new set of standards which are concerned with occupational incorporation monitoring of individuals handling non-sealed radioactive material. This set of standards is expected to consist of three parts discussing the general necessity and frequency, the requirements for monitoring institutions, and the determination and rigorous calculation of committed effective dose after incorporation of radioactive material, respectively. Considerations of the requirements for routine monitoring laboratories have led to an evaluation of the detection limits for routine monitoring equipment. For a selected set of radionuclides, these detection limits are investigated in detail. The main emphasis is placed on the decay chains of naturally occurring radionuclides showing some significant potential for being out of equilibrium due to chemical processes in certain mining industries. The radionuclides considered in this paper are 226Ra, 228Ra, 228Th, 232Th, 234U, 235U, and 238U. Given the routine monitoring intervals of the Austrian Standard, these detection limits are translated into information on committed effective dose. This paper investigates whether routine monitoring equipment is sufficient to ensure compliance with EC directive 96/29/Euratom for this selected set of radionuclides. (Author) 9 refs

  7. Detection limits by EPR spectroscopy of cumulated doses ionizing radiations in molluscs shells

    International Nuclear Information System (INIS)

    Ostrowski, K.; Burlinska, G.; Dziedzic-Goclawska, A.; Stachowicz, W.; Michalik, J.; Sadlo, J.

    1997-01-01

    The exposure of waters to ionizing radiation from radionuclides stored in concrete containers or freed in nuclear accidents or underwater eruption might be difficult to be proved, when currents, rains, exchange of water displace sand soils or rocks in the bottom. Ionizing radiation evokes stable paramagnetic centers in the crystalline lattice of mineral components in bones as well as in exoskeletons of most molluscs, which are detected by the EPR spectroscopy and could be used as an indicator of the exposure to the action of radiation during prolonged period of time. (authors)

  8. Calculation of the detection limits for radionuclides identified in gamma-ray spectra based on post-processing peak analysis results.

    Science.gov (United States)

    Korun, M; Vodenik, B; Zorko, B

    2018-03-01

    A new method for calculating the detection limits of gamma-ray spectrometry measurements is presented. The method is applicable for gamma-ray emitters, irrespective of the influences of the peaked background, the origin of the background and the overlap with other peaks. It offers the opportunity for multi-gamma-ray emitters to calculate the common detection limit, corresponding to more peaks. The detection limit is calculated by approximating the dependence of the uncertainty in the indication on its value with a second-order polynomial. In this approach the relation between the input quantities and the detection limit are described by an explicit expression and can be easy investigated. The detection limit is calculated from the data usually provided by the reports of peak-analyzing programs: the peak areas and their uncertainties. As a result, the need to use individual channel contents for calculating the detection limit is bypassed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. The value and limitation thallium scintigraphy in the detection of coronary artery disease

    International Nuclear Information System (INIS)

    Khan, A.; Rehman, A.; Amin, W.; Khan, Z.A.; Ahmed, S.A.

    1986-01-01

    In this study we randomly selected 45 patients whose coronary angiograms were abnormal i.e. showing triple, double and single vessel disease out of a pool of 80 patients who had undergone stress thallium imaging and coronary angiography during the one year. Majority of these patients were males, their ages ranged between 34-54 years. Resting ECG's were normal in 25 patients, 15 patients had suffered inferior myocardial infraction and 5 had sustained anterior myocardial infraction in the past. Coronary angiography revealed triple vessel disease in 20 patients, double vessel disease in 15, and single vessel coronary artery disease in 10. We analysed their coronary angiograms and compared them with the scintigraphic finding. It is concluded that although thallium scanning has high sensitivity for detection of coronary artery disease in general, it has only moderate sensitivity for detection of stenosis in individual coronary arteries. In this study thallium scan identified 75% of RCA lesions, 66% of LAD lesions and 38% of circumflex lesions. The sensitivity is much higher in single vessel coronary artery disease. (author)

  10. Leak Detection in Waterworks: Comparison Between STFT and FFT with an Overcoming of Limitations

    Directory of Open Access Journals (Sweden)

    Lay-Ekuakille Aimé

    2017-12-01

    Full Text Available Detection of leakages in pipelines is a matter of continuous research because of the basic importance for a waterworks system is finding the point of the pipeline where a leak is located and − in some cases − a nature of the leak. There are specific difficulties in finding leaks by using spectral analysis techniques like FFT (Fast Fourier Transform, STFT (Short Term Fourier Transform, etc. These difficulties arise especially in complicated pipeline configurations, e.g. a zigzag one. This research focuses on the results of a new algorithm based on FFT and comparing them with a developed STFT technique. Even if other techniques are used, they are costly and difficult to be managed. Moreover, a constraint in the leak detection is the pipeline diameter because it influences accuracy of the adopted algorithm. FFT and STFT are not fully adequate for complex configurations dealt with in this paper, since they produce ill-posed problems with an increasing uncertainty. Therefore, an improved Tikhonov technique has been implemented to reinforce FFT and STFT for complex configurations of pipelines. Hence, the proposed algorithm overcomes the aforementioned difficulties due to applying a linear algebraic approach.

  11. Unmanned Aircraft Systems Detect and Avoid System: End-to-End Verification and Validation Simulation Study of Minimum Operations Performance Standards for Integrating Unmanned Aircraft into the National Airspace System

    Science.gov (United States)

    Ghatas, Rania W.; Jack, Devin P.; Tsakpinis, Dimitrios; Sturdy, James L.; Vincent, Michael J.; Hoffler, Keith D.; Myer, Robert R.; DeHaven, Anna M.

    2017-01-01

    As Unmanned Aircraft Systems (UAS) make their way to mainstream aviation operations within the National Airspace System (NAS), research efforts are underway to develop a safe and effective environment for their integration into the NAS. Detect and Avoid (DAA) systems are required to account for the lack of "eyes in the sky" due to having no human on-board the aircraft. The technique, results, and lessons learned from a detailed End-to-End Verification and Validation (E2-V2) simulation study of a DAA system representative of RTCA SC-228's proposed Phase I DAA Minimum Operational Performance Standards (MOPS), based on specific test vectors and encounter cases, will be presented in this paper.

  12. Information Limited Oligonucleotide Amplification Assay for Affinity-Based, Parallel Detection Studies.

    Directory of Open Access Journals (Sweden)

    Harish Bokkasam

    Full Text Available Molecular communication systems encounter similar constraints as telecommunications. In either case, channel crosstalk at the receiver end will result in information loss that statistical analysis cannot compensate. This is because in any communication channel there is a physical limit to the amount of information that can be transmitted. We present a novel and simple modified end amplification (MEA technique to generate reduced and defined amounts of specific information in form of short fragments from an oligonucleotide source that also contains unrelated and redundant information. Our method can be a valuable tool to investigate information overflow and channel capacity in biomolecular recognition systems.

  13. Opportunistic mammography screening provides effective detection rates in a limited resource healthcare system.

    Science.gov (United States)

    Teh, Yew-Ching; Tan, Gie-Hooi; Taib, Nur Aishah; Rahmat, Kartini; Westerhout, Caroline Judy; Fadzli, Farhana; See, Mee-Hoong; Jamaris, Suniza; Yip, Cheng-Har

    2015-05-15

    Breast cancer is the leading cause of cancer deaths in women world-wide. In low and middle income countries, where there are no population-based mammographic screening programmes, late presentation is common, and because of inadequate access to optimal treatment, survival rates are poor. Mammographic screening is well-studied in high-income countries in western populations, and because it has been shown to reduce breast cancer mortality, it has become part of the healthcare systems in such countries. However the performance of mammographic screening in a developing country is largely unknown. This study aims to evaluate the performance of mammographic screening in Malaysia, a middle income country, and to compare the stage and surgical treatment of screen-detected and symptomatic breast cancer. A retrospective review of 2510 mammograms performed from Jan to Dec 2010 in a tertiary medical centre is carried out. The three groups identified are the routine (opportunistic) screening group, the targeted (high risk) screening group and the diagnostic group. The performance indicators of each group is calculated, and stage at presentation and treatment between the screening and diagnostic group is analyzed. The cancer detection rate in the opportunistic screening group, targeted screening group, and the symptomatic group is 0.5 %, 1.25 % and 26 % respectively. The proportion of ductal carcinoma in situ is 23.1 % in the two screening groups compared to only 2.5 % in the diagnostic group. Among the opportunistic screening group, the cancer detection rate was 0.2 % in women below 50 years old compared to 0.65 % in women 50 years and above. The performance indicators are within international standards. Early-staged breast cancer (Stage 0-2) were 84.6 % in the screening groups compared to 61.1 % in the diagnostic group. From the results, in a setting with resource constraints, targeted screening of high risk individuals will give a higher yield, and if more resources are

  14. System for detecting and limiting electrical ground faults within electrical devices

    International Nuclear Information System (INIS)

    Gaubatz, D.C.

    1990-01-01

    This paper discusses, in a nuclear power plant of a variety wherein a reactor is provided including a reactor vessel retaining a liquid metal coolant, a reactor core and an electromagnetic pump having inductive windings insulatively retained within the electrically conductive wall of an enclosure, the method for controlling electrical ground fault current between a the inductive winding and the walls. It comprises providing an electrically isolated power source by inductive coupling with the plant power supply; rectifying the power source to provide an isolated d.c. power source; providing an inverter powered from the isolated d.c. power source under the control of the plant control system for selectively energizing the inductive windings; providing a fault control conductor electrically connected with the pump enclosure wall and extending as an electrical return for ground fault current to the inverter; and providing an electrical resistance between the conductor and the isolated inverter having an impedance selected to limit the fault current below a predetermined value limiting arc damage at any the electrical ground fault location

  15. Decision Threshold and Detection Limit in Spectrometric Measurements. Part 1: Application to Gamma Spectrometry

    International Nuclear Information System (INIS)

    Perez, C.; Gasco, C.; Lopez, M. A.

    2010-01-01

    This report summarised the author's lecture of the advanced gamma spectrometry course organised by CIEMAT. The characteristic limits determination in gamma spectrometry generally is obtained through the programming that the trade marks offers to the client with the objective of the automatic calculation of the activity concentrations existing in a sample. In this report, the examples shown in the ISO 11929 standard are compared to the programming realised by Genie 2k for determining characteristic limits. The main difference of both is located in the uncertainty calculations due to the efficiency calibration that is considered by ISO and not by Genie 2K. Through implementation in the software developed by trade marks will be possible to introduce this uncertainty and to assimilate to the calculation done by ISO 11929. In the second part of this report will be analyzed the more complicated samples of this application as counting in a whole body counter (following ISO-28218 about Performance Criteria for radio bioassay), multiplet, overlapping, addition of several peaks for obtaining the activity concentration, etc. (Author) 19 refs.

  16. Sputum-Based Molecular Biomarkers for the Early Detection of Lung Cancer: Limitations and Promise

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Connie E. [Department of Medicine, Division of Pulmonary, Critical Care and Sleep Medicine. 462 First Avenue, NBV 7N24, New York, NY 10016 (United States); Tchou-Wong, Kam-Meng; Rom, William N., E-mail: william.rom@nyumc.org [Department of Medicine, Division of Pulmonary, Critical Care and Sleep Medicine. 462 First Avenue, NBV 7N24, New York, NY 10016 (United States); Department of Environmental Medicine, New York University School of Medicine, 57 Old Forge Road, Tuxedo, NY 10987 (United States)

    2011-07-19

    Lung cancer is the leading cause of cancer deaths, with an overall survival of 15% at five years. Biomarkers that can sensitively and specifically detect lung cancer at early stage are crucial for improving this poor survival rate. Sputum has been the target for the discovery of non-invasive biomarkers for lung cancer because it contains airway epithelial cells, and molecular alterations identified in sputum are most likely to reflect tumor-associated changes or field cancerization caused by smoking in the lung. Sputum-based molecular biomarkers include morphology, allelic imbalance, promoter hypermethylation, gene mutations and, recently, differential miRNA expression. To improve the sensitivity and reproducibility of sputum-based biomarkers, we recommend standardization of processing protocols, bronchial epithelial cell enrichment, and identification of field cancerization biomarkers.

  17. On-state voltage drop based power limit detection of IGBT inverters

    DEFF Research Database (Denmark)

    Trintis, Ionut; Ghimire, Pramod; Munk-Nielsen, Stig

    2015-01-01

    Power density is a key performance factor in order to reduce the cost and size of a power converter. Because of the unknown junction temperature, today’s design margins are relatively high to ensure safe and a reliable operation. In this paper, the on-state voltage drop is measured online for all...... insulated gate bipolar transistors (IGBTs) in the inverter, using advanced gate driver. The die temperature is estimated and monitored on each device during power converter operation. Based on the monitored temperature in real time, the maximum power capability is detected. The output power is increased...... until a safe operating temperature of power modules. This enable a power density is increased by 11.16 kW/litre to 19.13 kW/litre in a low voltage power stack which is typically used in wind power converters. Experiment results are shown for safe operation of converter at around 1.2 MW, which is built...

  18. The Impact of an ECV Service is Limited by Antenatal Breech Detection: A Retrospective Cohort Study.

    Science.gov (United States)

    Hemelaar, Joris; Lim, Lee N; Impey, Lawrence W

    2015-06-01

    External cephalic version (ECV) reduces the chance of breech presentation at term birth and lowers the chance of a cesarean delivery. ECV services are now in place in many units in the United Kingdom but their effectiveness is unknown. The aim of this study was to investigate the reasons for breech presentation at term birth. We performed a retrospective cohort study of 394 consecutive babies who were in breech presentation at term birth in a large United Kingdom maternity unit that offers ECV. The cohort was analyzed over two time periods 10 years apart: 1998-1999 and 2008-2009. Only 33.8 percent of women had undergone a (failed) ECV attempt. This low proportion was mainly because breech presentation was not diagnosed antenatally (27.9%). Other contributing factors were: ECV not offered by clinicians (12.2%), ECV declined by women (14%), and contraindications to ECV (10.7%). Over the 10-year period, the proportion of breech presentations that were not diagnosed antenatally increased from 23.2 to 32.5 percent (p = 0.04), which constituted 52.8 percent of women who had not undergone an ECV attempt in 2008-2009. Failure of clinicians to offer ECV reduced from 21.6 to 3.0 percent (p = 0.0001) and the proportion of women declining ECV decreased from 19.1 to 9.0 percent (p = 0.005). Overall, ECV attempts increased from 28.9 to 38.5 percent (p = 0.05). Although ECV counseling, referral, and attempt rates have increased, failure to detect breech presentation antenatally is the principal barrier to successful ECV. Improved breech detection would have a greater impact than methods to increase ECV success rates. © 2015 Wiley Periodicals, Inc.

  19. Beta-trace protein in ascites and pleural effusions: limits of CSF leakage detection.

    Science.gov (United States)

    Dietzel, Joanna; Krebs, Alexander; Böttcher, Dominique; Sieb, Manuela; Glocker, Michael O; Lüdemann, Jan; Roser, Markus; Dressel, Alexander

    2012-06-10

    Rhino- and/or otoliquorrhea can be diagnosed by detecting beta-trace protein (β-TP) in nasal or ear secretions, as β-TP is found in high concentrations in cerebrospinal fluid (CSF) but not in serum. CSF fistulae following trauma or surgery can also occur at other anatomical sites, resulting in CSF leakage into the thoracic and abdominal cavities. By analogy, determination of ß-TP has also been used to diagnose CSF admixture in pleural effusions and ascites. However, no systematic study has yet evaluated the concentrations of β-TP in such fluids in the absence of CSF. To determine the validity of β-TP determination as a marker for the presence of CSF, we investigated β-TP concentrations in pleural effusions and ascites without CSF admixture. Patients from whom samples of ascites or pleural effusion and a paired plasma sample were available were investigated. One hundred sixty-four patients were prospectively recruited. ß-TP concentrations were determined by nephelometry. Mass spectrometric proteome analysis confirmed the presence of ß-TP in the samples. Median β-TP concentrations detected in ascites and pleural effusions (range, 0.014-26.5 mg/L, median 2.29 mg/L) exceeded the corresponding plasma concentrations 2.6-fold. According to cutoffs published to diagnose rhino- and otoliquorrhea, between 6.1% and 95.7% of the specimens would have been erroneously rated CSF-positive. Protein analysis confirmed the presence of β-TP in pleural effusion and ascites. Ascites and pleural effusion contain high concentrations of β-TP that exceed the levels in corresponding plasma. Therefore, β-TP is not a specific marker for the presence of CSF in these fluids.

  20. Detecting deep venous thrombosis with limited flip angle gradient refocused MR imaging

    International Nuclear Information System (INIS)

    Spritzer, C.E.; Sussman, S.K.; Herfkens, R.J.; Blinder, R.A.; Saeed, M.; Vogler, J.A.; Baker, M.E.

    1987-01-01

    This study was undertaken to determine if limited flip angle gradient refocused MR pulse sequences (GRASS) could be used to accurately diagnose deep venous thrombosis (DVT). Sixteen patients (17 extremities) with possible DVT were prospectively evaluated with MR imaging and venography. Typical imaging parameters included a 16-msec echo time, 33-msec repetition time, 30 0 flip angle, and section thickness of 2 nex. MR imaging correctly disclosed the presence (nine cases) or absence (eight cases) of DVT. In one study, GRASS images overestimated the extent of clot due to slow venous blood flow. Subsequently the flip angle was varied to distinguish between venous thrombus and slow flow. When this technique was used, no false-positive studies occurred in the remaining patients. MR gradient refocused imaging appears to be an accurate aid for the diagnosis of DVT

  1. Lower limits of detection in using carbon nanotubes as thermoluminescent dosimeters of beta radiation

    Science.gov (United States)

    Alanazi, Abdulaziz; Jurewicz, Izabela; Alalawi, Amani I.; Alyahyawi, Amjad; Alsubaie, Abdullah; Hinder, Steven; Bañuls-Ciscar, Jorge; Alkhorayef, Mohammed; Bradley, D. A.

    2017-11-01

    World-wide, on-going intensive research is being seen in adaptation of carbon nanotubes (CNTs) for a wide variety of applications, particular interest herein being in the thermoluminescent (TL) properties of CNTs and their sensitivity towards energetic radiations. Using beta radiation delivering dose levels of a few Gy it has been observed in previous study that strain and impurity defects in CNTs give rise to significant TL yields, providing an initial measure of the extent to which electron trapping centres exist in various qualities of CNT, from super-pure to raw. This in turn points to the possibility that there may be considerable advantage in using such media for radiation dosimetry applications, including for in vivo dosimetry. CNTs also have an effective atomic number similar to that of adipose tissue, making them suitable for soft tissue dosimetry. In present investigations various single-wall carbon nanotubes (SWCNT) samples in the form of buckypaper have been irradiated to doses in the range 35-1.3 Gy, use being made of a 90Sr beta source, the response of the CNTs buckypaper with dose showing a trend towards linearity. It is shown for present production methodology for buckypaper samples that the raw SWCNT buckypaper offer the greatest sensitivity, detecting doses down to some few tens of mGy.

  2. Improving the limits of detection of low background alpha emission measurements

    Science.gov (United States)

    McNally, Brendan D.; Coleman, Stuart; Harris, Jack T.; Warburton, William K.

    2018-01-01

    Alpha particle emission - even at extremely low levels - is a significant issue in the search for rare events (e.g., double beta decay, dark matter detection). Traditional measurement techniques require long counting times to measure low sample rates in the presence of much larger instrumental backgrounds. To address this, a commercially available instrument developed by XIA uses pulse shape analysis to discriminate alpha emissions produced by the sample from those produced by other surfaces of the instrument itself. Experience with this system has uncovered two residual sources of background: cosmogenics and radon emanation from internal components. An R&D program is underway to enhance the system and extend the pulse shape analysis technique further, so that these residual sources can be identified and rejected as well. In this paper, we review the theory of operation and pulse shape analysis techniques used in XIA's alpha counter, and briefly explore data suggesting the origin of the residual background terms. We will then present our approach to enhance the system's ability to identify and reject these terms. Finally, we will describe a prototype system that incorporates our concepts and demonstrates their feasibility.

  3. Limitations of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) for detection of filarial antigens in serum

    International Nuclear Information System (INIS)

    Hamilton, R.G.; Alexander, E.; Adkinson, N.F.

    1984-01-01

    The performance of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) was examined for quantitation of filarial antigens (Brugia malayi and Dirofilaria immitis) in serum from infected human and animal hosts and non-infected controls. Multiple PEG concentrations were employed to determine the level of non-specific binding (NSB) in non-exposed human sera (NEHS) containing no filarial antigen. The NSB observed when 3 different 125 I-labelled IgG antibodies were added to 26 NEHS varied 3-fold and was correlated significantly with total serum IgM (r = 0.80, P 2 fragment of the 125 I-labelled antibody was used, but the correlation of NSB with total serum IgM remained significant (r = 0.57, P < 0.01). The presence of rheumatoid factor in NEHS sera also significantly increased NSB by an average of 3-fold. These effects eliminated the assay's ability to detect in sera from infected hosts filarial antigen the presence of which could be readily demonstrated by an immunoradiometric assay. The RIPEGA's precision (intra-assay coefficient of variation (CV) = 21% at 35% Bsub(max)) and reproducibility (inter-assay CV = 29% at 35% Bsub(max)) are less satisfactory than many alternative immunoassays. (Auth.)

  4. Limited magnetic resonance imaging of the lumbar spine has high sensitivity for detection of acute fractures, infection, and malignancy

    International Nuclear Information System (INIS)

    Wang, Benjamin; Fintelmann, Florian J.; Kamath, Ravi S.; Kattapuram, Susan V.; Rosenthal, Daniel I.

    2016-01-01

    The objective of this study is to determine how a limited protocol MR examination compares to a full conventional MR examination for the detection of non-degenerative pathology such as acute fracture, infection, and malignancy. A sample of 349 non-contrast MR exams was selected retrospectively containing a 3:1:1:1 distribution of negative/degenerative change only, acute fracture, infection, and malignancy. This resulted in an even distribution of pathology and non-pathology. A limited protocol MR exam was simulated by extracting T1-weighted sagittal and T2-weighted fat-saturated (or STIR) sagittal sequences from each exam and submitting them for blinded review by two experienced musculoskeletal radiologists. The exams were evaluated for the presence or absence of non-degenerative pathology. Interpretation of the limited exam was compared to the original report of the full examination. If either reader disagreed with the original report, the case was submitted for an unblinded adjudication process with the participation of a third musculoskeletal radiologist to establish a consensus diagnosis. There were five false negatives for a sensitivity of 96.9 % for the limited protocol MR exam. Infection in the psoas, paraspinal muscles, and sacroiliac joint, as well as acute fractures in transverse processes and sacrum were missed by one or more readers. No cases of malignancy were missed. Overall diagnostic accuracy was 96.0 % (335/349). MR imaging of the lumbar spine limited to sagittal T1-weighted and sagittal T2 fat-saturated (or STIR) sequences has high sensitivity for the detection of acute fracture, infection, or malignancy compared to a conventional MR examination. (orig.)

  5. Limited magnetic resonance imaging of the lumbar spine has high sensitivity for detection of acute fractures, infection, and malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Benjamin; Fintelmann, Florian J.; Kamath, Ravi S.; Kattapuram, Susan V.; Rosenthal, Daniel I. [Massachusetts General Hospital, Department of Radiology, Boston, MA (United States)

    2016-12-15

    The objective of this study is to determine how a limited protocol MR examination compares to a full conventional MR examination for the detection of non-degenerative pathology such as acute fracture, infection, and malignancy. A sample of 349 non-contrast MR exams was selected retrospectively containing a 3:1:1:1 distribution of negative/degenerative change only, acute fracture, infection, and malignancy. This resulted in an even distribution of pathology and non-pathology. A limited protocol MR exam was simulated by extracting T1-weighted sagittal and T2-weighted fat-saturated (or STIR) sagittal sequences from each exam and submitting them for blinded review by two experienced musculoskeletal radiologists. The exams were evaluated for the presence or absence of non-degenerative pathology. Interpretation of the limited exam was compared to the original report of the full examination. If either reader disagreed with the original report, the case was submitted for an unblinded adjudication process with the participation of a third musculoskeletal radiologist to establish a consensus diagnosis. There were five false negatives for a sensitivity of 96.9 % for the limited protocol MR exam. Infection in the psoas, paraspinal muscles, and sacroiliac joint, as well as acute fractures in transverse processes and sacrum were missed by one or more readers. No cases of malignancy were missed. Overall diagnostic accuracy was 96.0 % (335/349). MR imaging of the lumbar spine limited to sagittal T1-weighted and sagittal T2 fat-saturated (or STIR) sequences has high sensitivity for the detection of acute fracture, infection, or malignancy compared to a conventional MR examination. (orig.)

  6. Quantum-limited detection of millimeter waves using superconducting tunnel junctions

    International Nuclear Information System (INIS)

    Mears, C.A.

    1991-09-01

    The quasiparticle tunneling current in a superconductor-insulator- superconductor (SIS) tunnel junction is highly nonlinear. Such a nonlinearity can be used to mix two millimeter wave signals to produce a signal at a much lower intermediate frequency. We have constructed several millimeter and sub-millimeter wave SIS mixers in order to study high frequency response of the quasiparticle tunneling current and the physics of high frequency mixing. We have made the first measurement of the out-of-phase tunneling currents in an SIS tunnel junction. We have developed a method that allows us to determine the parameters of the high frequency embedding circuit by studying the details of the pumped I-V curve. We have constructed a 80--110 GHz waveguide-based mixer test apparatus that allows us to accurately measure the gain and added noise of the SIS mixer under test. Using extremely high quality tunnel junctions, we have measured an added mixer noise of 0.61 ± 0.36 quanta, which is within 25 percent of the quantum limit imposed by the Heisenberg uncertainty principle. This measured performance is in excellent agreement with that predicted by Tucker's theory of quantum mixing. We have also studied quasioptically coupled millimeter- and submillimeter-wave mixers using several types of integrated tuning elements. 83 refs

  7. Detection Limits of DLS and UV-Vis Spectroscopy in Characterization of Polydisperse Nanoparticles Colloids

    Directory of Open Access Journals (Sweden)

    Emilia Tomaszewska

    2013-01-01

    Full Text Available Dynamic light scattering is a method that depends on the interaction of light with particles. This method can be used for measurements of narrow particle size distributions especially in the range of 2–500 nm. Sample polydispersity can distort the results, and we could not see the real populations of particles because big particles presented in the sample can screen smaller ones. Although the theory and mathematical basics of DLS technique are already well known, little has been done to determine its limits experimentally. The size and size distribution of artificially prepared polydisperse silver nanoparticles (NPs colloids were studied using dynamic light scattering (DLS and ultraviolet-visible (UV-Vis spectroscopy. Polydisperse colloids were prepared based on the mixture of chemically synthesized monodisperse colloids well characterized by atomic force microscopy (AFM, transmission electron microscopy (TEM, DLS, and UV-Vis spectroscopy. Analysis of the DLS results obtained for polydisperse colloids reveals that several percent of the volume content of bigger NPs could screen completely the presence of smaller ones. The presented results could be extremely important from nanoparticles metrology point of view and should help to understand experimental data especially for the one who works with DLS and/or UV-Vis only.

  8. Limited role of gadolinium to detect active sacroiliitis on MRI in juvenile spondyloarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Herregods, N.; Leus, A.; Verstraete, K.; Jans, L. [Ghent University Hospital, Department of Radiology and Medical Imaging, Ghent (Belgium); Jaremko, J.L. [University of Alberta Hospital, Department of Radiology and Diagnostic Imaging, Edmonton, AB (Canada); Baraliakos, X. [Ruhr-University Bochum, Rheumazentrum Ruhrgebiet, Herne (Germany); Dehoorne, J. [Ghent University Hospital, Department of Pediatric Rheumatology, Ghent (Belgium)

    2015-11-15

    The aim of this study is to determine the added diagnostic value of contrast-enhanced (CE) magnetic resonance imaging (MRI) compared to routine non contrast-enhanced MRI to detect active sacroiliitis in clinically juvenile spondyloarthritis (JSpA). A total of 80 children clinically suspected for sacroiliitis prospectively underwent MRI of the sacroiliac (SI) joints. Axial and coronal T1-weighted (T1), Short-tau inversion recovery (STIR) and fat-saturated T1-weighted gadolinium-DTPA (Gd) contrast-enhanced (T1/Gd) sequences were obtained. The presence of bone marrow edema (BME), capsulitis, enthesitis, high intra-articular STIR signal, synovial enhancement and a global diagnostic impression of the MRI for diagnosis of sacroiliitis was recorded. STIR and T1/Gd sequences had 100 % agreement for depiction of BME, capsulitis and enthesitis. High intra-articular STIR signal was seen in 18/80 (22.5 %) patients, 15 (83 %) of whom also showed synovial enhancement in the T1/Gd sequence. Sensitivity (SN) and specificity (SP) for a clinical diagnosis of JSpA were similar for high STIR signal (SN = 33 %, SP = 85 %) and T1/Gd synovial enhancement (SN = 36 %, SP = 92 %). Positive likelihood ratio (LR+) for JSpA was twice as high for synovial enhancement than high STIR signal (4.5 compared to 2.2). Global diagnostic impression was similar (STIR: SN = 55 %, SP = 87 %, LR + =4.2; T1/Gd: SN = 55 %, SP = 92 %, LR + = 6.9). MRI without contrast administration is sufficient to identify bone marrow edema, capsulitis and retroarticular enthesitis as features of active sacroiliitis in juvenile spondyloarthritis. In selected cases when high STIR signal in the joint is the only finding, gadolinium-enhanced images may help to confirm the presence of synovitis. (orig.)

  9. Pushing the limits: detecting H2 emission from faint bipolar planetary nebulae in the IPHAS sample

    Science.gov (United States)

    Ramos-Larios, G.; Guerrero, M. A.; Sabin, L.; Santamaría, E.

    2017-09-01

    We have obtained deep narrowband images in the near-infrared H2 λ2.122 μm emission line for a sample of 15 faint Isaac Newton Telescope Photometric H α Survey (IPHAS) bipolar planetary nebulae (PNe) to search for molecular material. H2 emission is found in most of them (14 out of 15), mostly associated with rings at their equatorial regions and with their bipolar lobes. These detections add to the high occurrence of H2 emission among bipolar PNe reported in previous works, resulting from the large reservoir of molecular material in these sources and the suitable excitation conditions for H2 emission. The correlation between detailed bipolar morphology and H2 luminosity is also confirmed: bipolar PNe with broad equatorial rings (R-BPNe) have almost no continuum emission, are H2 brighter and have larger H2/Br γ line ratio than bipolar PNe with pinched equatorial waists (W-BPNe). The origin of this dichotomy is unclear. The larger size and age of R-BPNe are consistent with shock excitation of H2, whereas ultraviolet pumping is most likely the excitation mechanism in the smaller and younger W-BPNe, which would explain their lower H2 luminosity. Although both types of bipolar PNe seem to proceed from the same progenitor population, this does not imply that R-BPNe descend from W-BPNe. Otherwise, we note that some of the H2-weak bipolar PNe harbor post-common envelope binary systems and symbiotic stars. Finally, we suggest that the long-living H2 emission from R-BPNe arises from a discrete distribution of compact knots embedded within the ionized gas at the equatorial region.

  10. Improved detection limit in rapid detection of human enterovirus 71 and coxsackievirus A16 by a novel reverse transcription-isothermal multiple-self-matching-initiated amplification assay.

    Science.gov (United States)

    Ding, Xiong; Nie, Kai; Shi, Lei; Zhang, Yong; Guan, Li; Zhang, Dan; Qi, Shunxiang; Ma, Xuejun

    2014-06-01

    Rapid detection of human enterovirus 71 (EV71) and coxsackievirus A16 (CVA16) is important in the early phase of hand-foot-and-mouth disease (HFMD). In this study, we developed and evaluated a novel reverse transcription-isothermal multiple-self-matching-initiated amplification (RT-IMSA) assay for the rapid detection of EV71 and CVA16 by use of reverse transcriptase, together with a strand displacement DNA polymerase. Real-time RT-IMSA assays using a turbidimeter and visual RT-IMSA assays to detect EV71 and CVA16 were established and completed in 1 h, and the reported corresponding real-time reverse transcription-loop-mediated isothermal amplification (RT-LAMP) assays targeting the same regions of the VP1 gene were adopted as parallel tests. Through testing VP1 RNAs transcribed in vitro, the real-time RT-IMSA assays exhibited better linearity of quantification, with R(2) values of 0.952 (for EV71) and 0.967 (for CVA16), than the real-time RT-LAMP assays, which had R(2) values of 0.803 (for EV71) and 0.904 (for CVA16). Additionally, the detection limits of the real-time RT-IMSA assays (approximately 937 for EV71 and 67 for CVA16 copies/reaction) were higher than those of real-time RT-LAMP assays (approximately 3,266 for EV71 and 430 for CVA16 copies/reaction), and similar results were observed in the visual RT-IMSA assays. The new approaches also possess high specificities for the corresponding targets, with no cross-reactivity observed. In clinical assessment, compared to commercial reverse transcription-quantitative PCR (qRT-PCR) kits, the diagnostic sensitivities of the real-time RT-IMSA assays (96.4% for EV71 and 94.6% for CVA16) were higher than those of the real-time RT-LAMP assays (91.1% for EV71 and 90.8% for CVA16). The visual RT-IMSA assays also exhibited the same results. In conclusion, this proof-of-concept study suggests that the novel RT-IMSA assay is superior to the RT-LAMP assay in terms of detection limit and has the potential to rapidly detect EV71

  11. Detection limits of absorbed dose of ionizing radiation in molluscan shells as determined by e.p.r. spectroscopy

    International Nuclear Information System (INIS)

    Stachowicz, W.; Michalik, J.; Burlinska, G.; Sadlo, J.; Dziedzic-Goclawska, A.; Ostrowski, K.

    1995-01-01

    The exposure of waters to ionizing radiation from radionuclides imprisoned in dumped nuclear waste containers, freed in nuclear submarine accidents or released in underwater magma eruptions are difficult to be evaluated by conventional radiometric methods. Ionizing radiation evokes stable paramagnetic centers in crystalline lattice of mineral components in bone skeletons of mammals and fishes as well as in exoskeletons of mollusca. They give rise in e.p.r. to specific, extremely stable signals which are proposed to be applied as indicators of radiation exposure levels. In the present study the e.p.r. detection limits of the dose of ionizing radiation absorbed in shells of fresh water and marine mollusca (selected species) have been estimated. It has been found that with fresh water mollusca the dose of 1-2 Gy can be detected, while the sea water mollusca by one order of magnitude lower, i.e. about 0.1 Gy. (author)

  12. Possibilities for decreasing detection limits of analytical methods for determination of transformation products of unsymmetrical dimethylhydrazine in environmental samples

    Directory of Open Access Journals (Sweden)

    Bulat Kenessov

    2015-12-01

    Full Text Available Most rockets of middle and heavy class launched from Kazakhstan, Russia, China and other countries still use highly toxic unsymmetrical dimethylhydrazine (UDMH as a liquid propellant. Study of migration, distribution and accumulation of UDMH transformation products in environment and human health impact assessment of space rocket activity are currently complicated due to the absence of analytical methods allowing detection of trace concentrations of these compounds in analyzed samples. This paper reviews methods and approaches, which can be applied for development of such methods. Detection limits at a part-per-trillion (ppt level may be achieved using most selective and sensitive methods based on gas or liquid chromatography in combination of tandem or high-resolution mass spectrometry. In addition, 1000-fold concentration of samples or integrated sample preparation methods, e.g., dynamic headspace extraction, are required. Special attention during development and application of such methods must be paid to purity of laboratory air, reagents, glassware and analytical instruments.

  13. Protein biomarkers on tissue as imaged via MALDI mass spectrometry: A systematic approach to study the limits of detection.

    Science.gov (United States)

    van de Ven, Stephanie M W Y; Bemis, Kyle D; Lau, Kenneth; Adusumilli, Ravali; Kota, Uma; Stolowitz, Mark; Vitek, Olga; Mallick, Parag; Gambhir, Sanjiv S

    2016-06-01

    MALDI mass spectrometry imaging (MSI) is emerging as a tool for protein and peptide imaging across tissue sections. Despite extensive study, there does not yet exist a baseline study evaluating the potential capabilities for this technique to detect diverse proteins in tissue sections. In this study, we developed a systematic approach for characterizing MALDI-MSI workflows in terms of limits of detection, coefficients of variation, spatial resolution, and the identification of endogenous tissue proteins. Our goal was to quantify these figures of merit for a number of different proteins and peptides, in order to gain more insight in the feasibility of protein biomarker discovery efforts using this technique. Control proteins and peptides were deposited in serial dilutions on thinly sectioned mouse xenograft tissue. Using our experimental setup, coefficients of variation were biomarkers and a new benchmarking strategy that can be used for comparing diverse MALDI-MSI workflows. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Detection Limit of Smectite by Chemin IV Laboratory Instrument: Preliminary Implications for Chemin on the Mars Science Laboratory Mission

    Science.gov (United States)

    Archilles, Cherie; Ming, D. W.; Morris, R. V.; Blake, D. F.

    2011-01-01

    The CheMin instrument on the Mars Science Laboratory (MSL) is an miniature X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of detecting the mineralogical and elemental compositions of rocks, outcrops and soils on the surface of Mars. CheMin uses a microfocus-source Co X-ray tube, a transmission sample cell, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CRISM and OMEGA have identified the presence of phyllosilicates at several locations on Mars including the four candidate MSL landing sites. The objective of this study was to conduct preliminary studies to determine the CheMin detection limit of smectite in a smectite/olivine mixed mineral system.

  15. Scheme for efficient extraction of low-frequency signal beyond the quantum limit by frequency-shift detection.

    Science.gov (United States)

    Yang, R G; Zhang, J; Zhai, Z H; Zhai, S Q; Liu, K; Gao, J R

    2015-08-10

    Low-frequency (Hz~kHz) squeezing is very important in many schemes of quantum precision measurement. But it is more difficult than that at megahertz-frequency because of the introduction of laser low-frequency technical noise. In this paper, we propose a scheme to obtain a low-frequency signal beyond the quantum limit from the frequency comb in a non-degenerate frequency and degenerate polarization optical parametric amplifier (NOPA) operating below threshold with type I phase matching by frequency-shift detection. Low-frequency squeezing immune to laser technical noise is obtained by a detection system with a local beam of two-frequency intense laser. Furthermore, the low-frequency squeezing can be used for phase measurement in Mach-Zehnder interferometer, and the signal-to-noise ratio (SNR) can be enhanced greatly.

  16. Effect of sample matrix composition on INAA sample weights, measurement precisions, limits of detection, and optimum conditions

    International Nuclear Information System (INIS)

    Guinn, V.P.; Nakazawa, L.; Leslie, J.

    1984-01-01

    The instrumental neutron activation analysis (INAA) Advance Prediction Computer Program (APCP) is extremely useful in guiding one to optimum subsequent experimental analyses of samples of all types of matrices. By taking into account the contributions to the cumulative Compton-continuum levels from all significant induced gamma-emitting radionuclides, it provides good INAA advance estimates of detectable photopeaks, measurement precisions, concentration lower limits of detection (LOD's) and optimum irradiation/decay/counting conditions - as well as of the very important maximum allowable sample size for each set of conditions calculated. The usefulness and importance of the four output parameters cited in the title are discussed using the INAA APCP outputs for NBS SRM-1632 Coal as the example

  17. Experimental study to optimize time resolution and detection limit of online 222Rn-in-water measurements

    International Nuclear Information System (INIS)

    Just, G.; Freyer, K.; Treutler, H.C.; Philipsborn, H. von

    2001-01-01

    The possibility to detect short-term variations of the activity concentration of 222 Rn in water by online monitoring with temporal resolutions of a few minutes and a lower limit of detection of about 1 Bq/l enhances the applicability of such measurements. New applications would be possible in the field of hydro-geology in which Rn is used as tracer gas, the monitoring of pumping procedures, for the study of exchange processes during groundwater sampling and for various applications with geophysical effects. A suitable, simple method is the measuring principle proposed by Surbeck (Fribourg) some years ago which is based on the separation of air and water by a diffusion membrane. Process parameters enhancing the time resolution of the method as well as the efficiency of different radon detectors have been studied. (orig.) [de

  18. Determining the 95% limit of detection for waterborne pathogen analyses from primary concentration to qPCR

    Science.gov (United States)

    Stokdyk, Joel P.; Firnstahl, Aaron; Spencer, Susan K.; Burch, Tucker R; Borchardt, Mark A.

    2016-01-01

    The limit of detection (LOD) for qPCR-based analyses is not consistently defined or determined in studies on waterborne pathogens. Moreover, the LODs reported often reflect the qPCR assay alone rather than the entire sample process. Our objective was to develop an approach to determine the 95% LOD (lowest concentration at which 95% of positive samples are detected) for the entire process of waterborne pathogen detection. We began by spiking the lowest concentration that was consistently positive at the qPCR step (based on its standard curve) into each procedural step working backwards (i.e., extraction, secondary concentration, primary concentration), which established a concentration that was detectable following losses of the pathogen from processing. Using the fraction of positive replicates (n = 10) at this concentration, we selected and analyzed a second, and then third, concentration. If the fraction of positive replicates equaled 1 or 0 for two concentrations, we selected another. We calculated the LOD using probit analysis. To demonstrate our approach we determined the 95% LOD for Salmonella enterica serovar Typhimurium, adenovirus 41, and vaccine-derived poliovirus Sabin 3, which were 11, 12, and 6 genomic copies (gc) per reaction (rxn), respectively (equivalent to 1.3, 1.5, and 4.0 gc L−1 assuming the 1500 L tap-water sample volume prescribed in EPA Method 1615). This approach limited the number of analyses required and was amenable to testing multiple genetic targets simultaneously (i.e., spiking a single sample with multiple microorganisms). An LOD determined this way can facilitate study design, guide the number of required technical replicates, aid method evaluation, and inform data interpretation.

  19. Resistance of lichens to simulated galactic cosmic radiation: limits of survival capacity and biosignature detection

    Science.gov (United States)

    de la Torre Noetzel, Rosa; Miller, Ana Z.; Cubero, Beatriz; Raguse, Marina; Meessen, Joachim

    2016-04-01

    Space constitutes an extremely harmful environment for survival of terrestrial organisms. Amongst extremophiles on Earth, lichens are one of the most resistant organisms to harsh terrestrial environments, as well as some species of microorganisms, such as bacteria (Moeller et al., 2010), criptoendolithic cyanobacteria and lithic fungi (de los Ríos et al. 2004). To study the survival capacity of lichens to the harmful radiation environment of space, we have selected the lichen Circinaria gyrosa, an astrobiological model defined by its high capacity of resistance to space conditions (De la Torre et al. 2010) and to a simulated Mars environment (Sanchez et al., 2012). Samples were irradiated with four types of space-relevant ionizing radiation in the STARLIFE campaign: helium and iron ion doses (up to 2,000 Gy), X-ray doses (up to 5,000 Gy) and ultra-high γ-ray doses (from 6 to 113 kGy). Results on resistance of C. gyrosa to space-relevant ionizing radiation and its post-irradiation viability were obtained by: (i) chlorophyll a fluorescence of photosystem II (PS II); (ii) epifluorescence microscopy; (iii) confocal laser-scanning microscopy (CLSM), and (iv) field emission scanning electron microscopy (FESEM). Results of photosynthetic activity and epifluorescence showed no significant changes on the viability of C. gyrosa with increasing doses of helium and iron ions as well as X-rays. In contrast, γ-irradiation elicited significant dose-correlated effects as revealed by all applied techniques. Relevant is the presence of whewellite-like crystals, detected by FESEM on C. gyrosa thalli after high irradiation doses, which has been also identified in previous Mars simulation studies (Böttcher et al., 2014). These studies contribute to the better understanding of the adaptability of extremophile organisms to harsh environments, as well as to estimate the habitability of a planet's surface, like Mars; they will be important for planning experiments on the search of life

  20. Comparison of approximate formulas for decision levels and detection limits for paired counting with the exact results

    International Nuclear Information System (INIS)

    Potter, W.E.

    2005-01-01

    The exact probability density function for paired counting can be expressed in terms of modified Bessel functions of integral order when the expected blank count is known. Exact decision levels and detection limits can be computed in a straightforward manner. For many applications perturbing half-integer corrections to Gaussian distributions yields satisfactory results for decision levels. When there is concern about the uncertainty for the expected value of the blank count, a way to bound the errors of both types using confidence intervals for the expected blank count is discussed. (author)

  1. Detection limit improvements forecasted at CTBTO IMS radionuclide stations based on size separation of aerosols by aerodynamic diameter

    International Nuclear Information System (INIS)

    Biegalski, S.; Ezekoye, O.A.; Pena, J.M.; Waye, S.; Pickering, M.

    2008-01-01

    Studies show that aerosols with natural activity have an aerodynamic diameter in the range of 0.1 to 1 μm. In contrast, nuclear explosions generally produce radioactive aerosols with aerodynamic diameters less than 0.1 μm and greater than 1 μm. These differences in aerosol sizes are quite fortuitous because they allow aerosol aerodynamic diameter to be utilized as a physical property to separate aerosols of natural origin from those produced in a nuclear explosion. Data collected in Austin, TX and at U.S. CTBT IMS radionuclide stations have been utilized to forecast detection limit improvements possible given an aerosol size separation capability. (author)

  2. Statistical data treatment of environmental radiological measurements extracted by the CSN and submitted to a lower limit of detection

    International Nuclear Information System (INIS)

    Felipe, A.; Martin, M.; Valdes, T.

    1992-01-01

    The quantification of radiological environmental contamination is usually carried out by mean of sample measurements around the emission points. These data are submitted to the so called Lower Limit of Detection which makes data to be statistically censored. The following topics have been included in our work: (a) Correction of mean values of the radiological contamination levels by the estimation of its distribution. (b) Development of the computer programs to carry out the former correction of estimators. (c) Estimation of the existing correlation among the different types of measurements. (author)

  3. Estimation of the detection limit of an experimental model of tritium storage bed designed for 'in-situ' accountability

    International Nuclear Information System (INIS)

    Bulubasa, Gheorghe; Bidica, Nicolae; Stefanescu, Ioan; Bucur, Ciprian; Deaconu, Mariea

    2009-01-01

    During the water detritiation process most of the tritium inventory is transferred from water into the gaseous phase, then it is further enriched and finally extracted and safely stored. The control of tritium inventory is an acute issue from several points of view: - Financially - tritium is an expensive material; - Safeguard - tritium is considered as nuclear material of strategic importance; - Safety - tritium is a radioactive material: requirements for documented safety analysis report (to ensure strict limits on the total tritium allowed) and for evaluation of accident consequences associated with that inventory. Large amounts of tritium can be stored, in a very safely manner, as metal tritides. A bench-scale experiment of a tritium storage bed with integrated system for in-situ tritium inventory accountancy was designed and developed at ICSI Rm. Valcea. The calibration curve and the detection limit for this experimental model of tritium storage bed were determined. The experimental results are presented in this paper. (authors)

  4. Rising above the Minimum Wage.

    Science.gov (United States)

    Even, William; Macpherson, David

    An in-depth analysis was made of how quickly most people move up the wage scale from minimum wage, what factors influence their progress, and how minimum wage increases affect wage growth above the minimum. Very few workers remain at the minimum wage over the long run, according to this study of data drawn from the 1977-78 May Current Population…

  5. Determination of chromium(VI) in water by PIXE analysis using ion exchange paper. Limit of detection and interference by coexisting anions

    International Nuclear Information System (INIS)

    Thomyasirigul, Sureerat; Fukuda, Hitoshi; Hasegawa, Jun; Oguri, Yoshiyuki

    2009-01-01

    Concerning the PIXE analysis of Cr(VI) in water using ion-exchange filters, the limit of detection (LOD) and the influence of matrix anions were investigated. In order to look for the experimental condition for obtaining the minimum LOD, we measured the Cr-Kα X-ray counts and background counts under the Kα X-ray peak as a function of the incident proton energy and the thickness of the Mylar absorber foil in front of the detector. To investigate the interference by coexisting anions, each of PO 4 3- , SO 4 2- , NO 3 - , Cl - , and F - ions and Cr(VI) ions were mixed in aqueous solutions and adsorbed on DE81-DEAE cellulose paper, a weakly basic anion exchanger with diethylaminoethyl functional groups. Then the filter samples were measured by PIXE using 2.5 MeV proton beams. We obtained a LOD of 0.16 μg or 8 ppb for 20 mL samples at a proton energy of 2.5 MeV and a Mylar film thickness of 50 or 100 μm. The experimental results on the mixed solutions indicated that NO 3 - , Cl - , and F - as coexisting ions didn't interfere significantly with determination of a 50 μg/L Cr(VI) concentration for 40 mL total solution volume, despite the total amount of anions was about 90% of ion exchange capacity of a filter. On the other hand, slight interferences by PO 4 3- ions were observed. However, under the same condition, we found that if the total amount of SO 4 2- ions was higher than 20% of ion exchange capacity, they induced significant interferences in determining Cr(VI). (author)

  6. Astrophysical limitations to the identification of dark matter: Indirect neutrino signals vis-a-vis direct detection recoil rates

    International Nuclear Information System (INIS)

    Serpico, Pasquale D.; Bertone, Gianfranco

    2010-01-01

    A convincing identification of dark matter (DM) particles can probably be achieved only through a combined analysis of different detections strategies, which provides an effective way of removing degeneracies in the parameter space of DM models. In practice, however, this program is made complicated by the fact that different strategies depend on different physical quantities, or on the same quantities but in a different way, making the treatment of systematic errors rather tricky. We discuss here the uncertainties on the recoil rate in direct-detection experiments and on the muon rate induced by neutrinos from dark matter annihilations in the Sun, and we show that, contrarily to the local DM density or overall cross section scale, irreducible astrophysical uncertainties affect the two rates in a different fashion, therefore limiting our ability to reconstruct the parameters of the dark matter particles. By varying within their respective errors astrophysical parameters such as the escape velocity and the velocity dispersion of dark matter particles, we show that the uncertainty on the relative strength of the neutrino and direct-detection signal is as large as a factor of 2 for typical values of the parameters, but can be even larger in some circumstances.

  7. A quantitative method for determining a representative detection limit of the forensic luminol test for latent bloodstains.

    Science.gov (United States)

    Cassidy, Brianna M; Lu, Zhenyu; Martin, Jennifer P; Tazik, Shawna K; Kellogg, Katie W; DeJong, Stephanie A; Belliveau, Elle O; Kilgore, Katherine E; Ervin, Samantha M; Meece-Rayle, Mackenzie; Abraham, Alyssa M; Myrick, Michael L; Morgan, Stephen L

    2017-09-01

    The luminol test has been used for over 60 years by forensic investigators for presumptive identification of blood and visualization of blood splatter patterns. Multiple studies have estimated the limit of detection (LD) for bloodstains when luminol is employed, with results ranging from 100× to 5,000,000× dilute. However, these studies typically have not identified and controlled important experimental variables which may affect the luminol LD for bloodstains. Without control of experimental parameters in the laboratory, variables which affect the potential of presumptive bloodstain test methods remain largely unknown, and comparisons required to establish new, more powerful detection methods are simply impossible. We have developed a quantitative method to determine the relationship between the amount of blood present and its reaction with luminol by measuring, under controlled conditions, the resulting chemiluminescent intensity with a video camera, combined with processing of the digital intensity data. The method resulted in an estimated LD for bloodstains on cotton fabric at ∼200,000× diluted blood with a specific luminol formulation. Although luminol is the focus of this study, the experimental protocol used could be modified to study effects of variables using other blood detection reagents. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Does parallel item content on WOMAC's Pain and Function Subscales limit its ability to detect change in functional status?

    Directory of Open Access Journals (Sweden)

    Kennedy Deborah M

    2004-06-01

    Full Text Available Abstract Background Although the Western Ontario and McMaster University Osteoarthritis Index (WOMAC is considered the leading outcome measure for patients with osteoarthritis of the lower extremity, recent work has challenged its factorial validity and the physical function subscale's ability to detect valid change when pain and function display different profiles of change. This study examined the etiology of the WOMAC's physical function subscale's limited ability to detect change in the presence of discordant changes for pain and function. We hypothesized that the duplication of some items on the WOMAC's pain and function subscales contributed to this shortcoming. Methods Two eight-item physical function scales were abstracted from the WOMAC's 17-item physical function subscale: one contained activities and themes that were duplicated on the pain subscale (SIMILAR-8; the other version avoided overlapping activities (DISSIMILAR-8. Factorial validity of the shortened measures was assessed on 310 patients awaiting hip or knee arthroplasty. The shortened measures' abilities to detect change were examined on a sample of 104 patients following primary hip or knee arthroplasty. The WOMAC and three performance measures that included activity specific pain assessments – 40 m walk test, stair test, and timed-up-and-go test – were administered preoperatively, within 16 days of hip or knee arthroplasty, and at an interval of greater than 20 days following the first post-surgical assessment. Standardized response means were used to quantify change. Results The SIMILAR-8 did not demonstrate factorial validity; however, the factorial structure of the DISSIMILAR-8 was supported. The time to complete the performance measures more than doubled between the preoperative and first postoperative assessments supporting the theory that lower extremity functional status diminished over this interval. The DISSIMILAR-8 detected this deterioration in functional

  9. The use of a European coinage alloy to compare the detection limits of mobile XRF systems. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Cesareo, R. [Struttura Dipartimentale di Matematica e Fisica, Universita di Sassari, Sassari (Italy); Ferretti, M. [CNR-Istituto per le Tecnologie Applicate ai Beni Culturali, Rome (Italy); Gigante, G.E. [Dipartimento di Fisica, Universita di Roma ' La Sapienza' , Rome (Italy); Guida, G. [Laboratorio di Chimica, Istituto Centrale per il Restauro, Rome (Italy); Moioli, P. [Unita Tecnico-Scientifica Materiali e Nuove Tecnologie, ENEA, Rome (Italy); Ridolfi, S. [Ars Mensurae, Rome (Italy); Roldan Garcia, C. [Unidad de Arqueometria, Instituto de Ciencia de Materiales, Universidad de Valencia, Valencia (Spain)

    2007-05-15

    The investigation of archaeological and historical materials makes use of techniques that, though borrowed from other fields of research and industrial production, frequently have to be 're-invented' because of peculiar characteristics of the analysed objects. Artistic relevance, limited movability, compositional and structural heterogeneity radically change the experimental approach and often require ad hoc designed equipment. These considerations also apply to x-ray fluorescence, especially regarding mobile systems. The extensive development and use of mobile spectrometers has produced an extremely diversified context and created the need for common criteria to evaluate their performances as well as the advisability of a survey on the existing equipment. This paper shows the feasibility of such an idea through a demonstrative survey that was carried out among users of different mobile x-ray fluorescence spectrometry (XRF) systems in the areas of Rome, Italy and Valencia, Spain. The experimental protocol was based on measuring spectrometer detection limits with the single standard method. The standard was the 50 Euro-cent coin, whose alloy is made of 89% Cu, 5% Al, 5% Zn, 1% Sn; the large spread of the European currency guarantees maximum availability. The experimental data show that the use of different x-ray tubes and detectors results in detection limits that may differ from each other by a factor of 6 for Zn and almost 100 for Sn; despite the large number of variables that in principle affect the performance, it was observed that the high voltage of the x-ray tube is the most important parameter. (authors)

  10. Coincidence detection of single-photon responses in the inner retina at the sensitivity limit of vision.

    Science.gov (United States)

    Ala-Laurila, Petri; Rieke, Fred

    2014-12-15

    Vision in starlight relies on our ability to detect single absorbed photons. Indeed, the sensitivity of dark-adapted vision approaches limits set by the quantal nature of light. This sensitivity requires neural mechanisms that selectively transmit quantal responses and suppress noise. Such mechanisms face an inevitable tradeoff because signal and noise cannot be perfectly separated, and rejecting noise also means rejecting signal. We report measurements of single-photon responses in the output signals of the primate retina. We find that visual signals arising from a few absorbed photons are read out fundamentally differently by primate On and Off parasol ganglion cells, key retinal output neurons. Off parasol cells respond linearly to near-threshold flashes, retaining sensitivity to each absorbed photon but maintaining a high level of noise. On parasol cells respond nonlinearly due to thresholding of their excitatory synaptic inputs. This nonlinearity reduces neural noise but also limits information about single-photon absorptions. The long-standing idea that information about each photon absorption is available for behavior at the sensitivity limit of vision is not universally true across retinal outputs. More generally, our work shows how a neural circuit balances the competing needs for sensitivity and noise rejection. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. A LIMIT ON THE NUMBER OF ISOLATED NEUTRON STARS DETECTED IN THE ROSAT ALL-SKY-SURVEY BRIGHT SOURCE CATALOG

    International Nuclear Information System (INIS)

    Turner, Monica L.; Rutledge, Robert E.; Letcavage, Ryan; Shevchuk, Andrew S. H.; Fox, Derek B.

    2010-01-01

    Using new and archival observations made with the Swift satellite and other facilities, we examine 147 X-ray sources selected from the ROSAT All-Sky-Survey Bright Source Catalog (RASS/BSC) to produce a new limit on the number of isolated neutron stars (INSs) in the RASS/BSC, the most constraining such limit to date. Independent of X-ray spectrum and variability, the number of INSs is ≤48 (90% confidence). Restricting attention to soft (kT eff < 200 eV), non-variable X-ray sources-as in a previous study-yields an all-sky limit of ≤31 INSs. In the course of our analysis, we identify five new high-quality INS candidates for targeted follow-up observations. A future all-sky X-ray survey with eROSITA, or another mission with similar capabilities, can be expected to increase the detected population of X-ray-discovered INSs from the 8-50 in the BSC, to (for a disk population) 240-1500, which will enable a more detailed study of neutron star population models.

  12. Minimum Error Entropy Classification

    CERN Document Server

    Marques de Sá, Joaquim P; Santos, Jorge M F; Alexandre, Luís A

    2013-01-01

    This book explains the minimum error entropy (MEE) concept applied to data classification machines. Theoretical results on the inner workings of the MEE concept, in its application to solving a variety of classification problems, are presented in the wider realm of risk functionals. Researchers and practitioners also find in the book a detailed presentation of practical data classifiers using MEE. These include multi‐layer perceptrons, recurrent neural networks, complexvalued neural networks, modular neural networks, and decision trees. A clustering algorithm using a MEE‐like concept is also presented. Examples, tests, evaluation experiments and comparison with similar machines using classic approaches, complement the descriptions.

  13. Matrix effect on the detection limit and accuracy in total reflection X-ray fluorescence analysis of trace elements in environmental and biological samples

    International Nuclear Information System (INIS)

    Karjou, J.

    2007-01-01

    The effect of matrix contents on the detection limit of total reflection X-ray fluorescence analysis was experimentally investigated using a set of multielement standard solutions (500 ng/mL of each element) in variable concentrations of NH 4 NO 3 . It was found that high matrix concentration, i.e. 0.1-10% NH 4 NO 3 , had a strong effect on the detection limits for all investigated elements, whereas no effect was observed at lower matrix concentration, i.e. 0-0.1% NH 4 NO 3 . The effect of soil and blood sample masses on the detection limit was also studied. The results showed decreasing the detection limit (in concentration unit, μg/g) with increasing the sample mass. However, the detection limit increased (in mass unit, ng) with increasing sample mass. The optimal blood sample mass of ca. 200 μg was sufficient to improve the detection limit of Se determination by total reflection X-ray fluorescence. The capability of total reflection X-ray fluorescence to analyze different kinds of samples was discussed with respect to the accuracy and detection limits based on certified and reference materials. Direct analysis of unknown water samples from several sources was also presented in this work

  14. Detection of Methicillin Resistant Staphylococcus aureus and Determination of Minimum Inhibitory Concentration of Vancomycin for Staphylococcus aureus Isolated from Pus/Wound Swab Samples of the Patients Attending a Tertiary Care Hospital in Kathmandu, Nepal

    Directory of Open Access Journals (Sweden)

    Raghabendra Adhikari

    2017-01-01

    Full Text Available The present study was conducted to evaluate the performance of cefoxitin disc diffusion method and oxacillin broth microdilution method for detection of methicillin resistant S. aureus (MRSA, taking presence of mecA gene as reference. In addition, inducible clindamycin resistance and beta-lactamase production were studied and minimum inhibitory concentration (MIC of vancomycin for S. aureus isolates was determined. A total of 711 nonrepeated pus/wound swab samples from different anatomic locations were included in the study. The Staphylococcus aureus was identified on the basis of colony morphology, Gram’s stain, and biochemical tests. A total of 110 (15.47% S. aureus isolates were recovered, of which 39 (35.50% isolates were identified as MRSA by cefoxitin disc diffusion method. By oxacillin broth microdilution method, 31.82% of the Staphylococcus aureus isolates were found to be MRSA. However, mecA gene was present in only 29.1% of the isolates. Further, beta-lactamase production was observed in 71.82% of the isolates, while inducible clindamycin resistance was found in 10% of S. aureus isolates. The MIC value of vancomycin for S. aureus ranged from 0.016 μg/mL to 1 μg/mL. On the basis of the absolute sensitivity (100%, both phenotypic methods could be employed for routine diagnosis of MRSA in clinical microbiology laboratory; however cefoxitin disc diffusion could be preferred over MIC method considering time and labour factor.

  15. Do Minimum Wages Fight Poverty?

    OpenAIRE

    David Neumark; William Wascher

    1997-01-01

    The primary goal of a national minimum wage floor is to raise the incomes of poor or near-poor families with members in the work force. However, estimates of employment effects of minimum wages tell us little about whether minimum wages are can achieve this goal; even if the disemployment effects of minimum wages are modest, minimum wage increases could result in net income losses for poor families. We present evidence on the effects of minimum wages on family incomes from matched March CPS s...

  16. Attempts to lower the detection limits of heavy metals in standardized grass cultures by using alternative growth substrates

    International Nuclear Information System (INIS)

    Winter, A.; Mueller, P.; Wagner, G.

    1992-01-01

    In addition to the use of standardized grass cultures (cf. VDI 3792) within the framework of an effect cadastre, grass cultures were tested on two non-contaminated substrates with nutrient solution in the greenhouse and in the open land during different exposure cycles. The results: As compared to the standard cultures on standardized soil, the cultures have the same or a better growth performance and better dry resistance on the artificial substrates; the blind values and the refore the detection limits in particular for cadmium are by far lower; four-week exposure periods with a two-week overlap have an improved information yield for the same amount of work throughout the investigation period as compared to a two-week exposure. Recommendations are derived from the results for a simplified application of the grass culture method in practice. (orig.) [de

  17. Using rapid-scan EPR to improve the detection limit of quantitative EPR by more than one order of magnitude.

    Science.gov (United States)

    Möser, J; Lips, K; Tseytlin, M; Eaton, G R; Eaton, S S; Schnegg, A

    2017-08-01

    X-band rapid-scan EPR was implemented on a commercially available Bruker ELEXSYS E580 spectrometer. Room temperature rapid-scan and continuous-wave EPR spectra were recorded for amorphous silicon powder samples. By comparing the resulting signal intensities the feasibility of performing quantitative rapid-scan EPR is demonstrated. For different hydrogenated amorphous silicon samples, rapid-scan EPR results in signal-to-noise improvements by factors between 10 and 50. Rapid-scan EPR is thus capable of improving the detection limit of quantitative EPR by at least one order of magnitude. In addition, we provide a recipe for setting up and calibrating a conventional pulsed and continuous-wave EPR spectrometer for rapid-scan EPR. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Chlorine-trapped CVD bilayer graphene for resistive pressure sensor with high detection limit and high sensitivity

    Science.gov (United States)

    Phuong Pham, Viet; Triet Nguyen, Minh; Park, Jin Woo; Kwak, Sung Soo; Nguyen, Dieu Hien Thi; Kyeom Mun, Mu; Danh Phan, Hoang; San Kim, Doo; Kim, Ki Hyun; Lee, Nae-Eung; Yeom, Geun Young

    2017-06-01

    Pressure sensing is one of the key functions for smart electronics. Considerably more effort is required to achieve the fabrication of pressure sensors that can imitate and overcome the sophisticated pressure sensing characteristics in nature and industry, especially in the innovation of materials and structures. Almost all of the pressure sensors reported until now have a high sensitivity at a low-pressure detection limit (type chlorine trap doping in the channel graphene with chlorine radicals without damaging the graphene. This work indicates that the ZGClG channel used for the pressure sensing device could also provide a simple and essential sensing platform for chemical-, medical-, and biological-sensing for future smart electronics.

  19. Limit of detection and threshold for positivity of the Centers for Disease Control and Prevention assay for factor VIII inhibitors.

    Science.gov (United States)

    Miller, C H; Boylan, B; Shapiro, A D; Lentz, S R; Wicklund, B M

    2017-10-01

    Essentials Immunologic methods detect factor VIII (FVIII) antibodies in some inhibitor-negative specimens. Specimens were tested by modified Nijmegen-Bethesda assay (NBA) and fluorescence immunoassay. The NBA with preanalytical heat inactivation detects FVIII inhibitors down to 0.2 NBU. IgG 4 frequency validates the established threshold for positivity of ≥ 0.5 NBU for this NBA. Background The Bethesda assay for measurement of factor VIII inhibitors called for quantification of positive inhibitors by using dilutions producing 25-75% residual activity (RA), corresponding to 0.4-2.0 Bethesda units, with the use of 'more sensitive methods' for samples with RA closer to 100% being recommended. The Nijmegen modification (Nijmegen-Bethesda assay [NBA]) changed the reagents used but not these calculations. Some specimens negative by the NBA have been shown to have FVIII antibodies detectable with sensitive immunologic methods. Objective To examine the performance at very low inhibitor titers of the Centers for Disease Control and Prevention (CDC)-modified NBA (CDC-NBA), which includes preanalytic heat inactivation to liberate bound anti-FVIII antibodies. Methods Specimens with known inhibitors were tested with the CDC-NBA. IgG 4 anti-FVIII antibodies were measured by fluorescence immunoassay (FLI). Results Diluted inhibitors showed linearity below 0.4 Nijmegen-Bethesda units (NBU). With four statistical methods, the limit of detection of the CDC-NBA was determined to be 0.2 NBU. IgG 4 anti-FVIII antibodies, which correlate most strongly with functional inhibitors, were present at rates above the background rate of healthy controls in specimens with titers ≥ 0.2 NBU and showed an increase in frequency from 14.3% at 0.4 NBU to 67% at the established threshold for positivity of 0.5 NBU. Conclusions The CDC-NBA can detect inhibitors down to 0.2 NBU. The FLI, which is more sensitive, demonstrates anti-FVIII IgG 4 in some patients with negative (NBA, supporting the need for

  20. Upper limits to the detection of ammonia from protoplanetary disks around HL Tauri and L1551-IRS 5

    Science.gov (United States)

    Gomez, Jose F.; Torrelles, Jose M.; Ho, Paul T. P.; Rodriguez, Luis F.; Canto, Jorge

    1993-01-01

    We present NH3(1, 1) and (2, 2) observations of the young stellar sources HL Tau and L1551-IRS 5 using the VLA in its B-configuration, which provides an angular resolution of about 0.4 arcsec (about 50 AU at 140 pc) at 1.3 cm wavelength. Our goal was to detect and resolve circumstellar molecular disks with radius of the order of 100 AU around these two sources. No ammonia emission was detected toward either of them. The 3-sigma levels were 2.7 mJy/beam and 3.9 mJy/beam for HL Tau and L1551-IRS 5, respectively, with a velocity resolution of about 5 km/s. With this nondetection, we estimate upper limits to the mass of the proposed protoplanetary molecular disks (within a radius of 10 AU from the central stars) on the order of 0.02/(X(NH3)/10 exp -8) solar mass for HL Tau and 0.1/(X(NH3)/10 exp -8) solar mass for L1551-IRS 5.

  1. Sandwiched gold/PNIPAm/gold microstructures for smart plasmonics application: towards the high detection limit and Raman quantitative measurements.

    Science.gov (United States)

    Elashnikov, R; Mares, D; Podzimek, T; Švorčík, V; Lyutakov, O

    2017-08-07

    A smart plasmonic sensor, comprising a layer of a stimuli-responsive polymer sandwiched between two gold layers, is reported. As a stimuli-responsive material, a monolayer of poly(N-isopropylacrylamide) (PNIPAm) crosslinked globules is used. A quasi-periodic structure of the top gold layer facilitates efficient excitation and serves as a support for plasmon excitation and propagation. The intermediate layer of PNIPAm efficiently entraps targeted molecules from solutions. The sensor structure was optimized for efficient light focusing in the "active" PNIPAm layer. The optimization was based on the time-resolved finite-element simulations, which take into account the thickness of gold layers, size of PNIPAm globules and Raman excitation wavelength (780 nm). The prepared structures were characterized using SEM, AFM, UV-Vis refractometry and goniometry. Additional AFM scans were performed in water at two temperatures corresponding to the collapsed and swollen PNIPAm states. The Raman measurements demonstrate a high detection limit and perfect reproducibility of the Raman scattering signal for the prepared sensor. In addition, the use of created SERS structures for the detection of relevant molecules in the medical, biological and safety fields was demonstrated.

  2. Quantifying Efficacy and Limits of Unmanned Aerial Vehicle (UAV Technology for Weed Seedling Detection as Affected by Sensor Resolution

    Directory of Open Access Journals (Sweden)

    José M. Peña

    2015-03-01

    Full Text Available In order to optimize the application of herbicides in weed-crop systems, accurate and timely weed maps of the crop-field are required. In this context, this investigation quantified the efficacy and limitations of remote images collected with an unmanned aerial vehicle (UAV for early detection of weed seedlings. The ability to discriminate weeds was significantly affected by the imagery spectral (type of camera, spatial (flight altitude and temporal (the date of the study resolutions. The colour-infrared images captured at 40 m and 50 days after sowing (date 2, when plants had 5–6 true leaves, had the highest weed detection accuracy (up to 91%. At this flight altitude, the images captured before date 2 had slightly better results than the images captured later. However, this trend changed in the visible-light images captured at 60 m and higher, which had notably better results on date 3 (57 days after sowing because of the larger size of the weed plants. Our results showed the requirements on spectral and spatial resolutions needed to generate a suitable weed map early in the growing season, as well as the best moment for the UAV image acquisition, with the ultimate objective of applying site-specific weed management operations.

  3. Quantifying efficacy and limits of unmanned aerial vehicle (UAV) technology for weed seedling detection as affected by sensor resolution.

    Science.gov (United States)

    Peña, José M; Torres-Sánchez, Jorge; Serrano-Pérez, Angélica; de Castro, Ana I; López-Granados, Francisca

    2015-03-06

    In order to optimize the application of herbicides in weed-crop systems, accurate and timely weed maps of the crop-field are required. In this context, this investigation quantified the efficacy and limitations of remote images collected with an unmanned aerial vehicle (UAV) for early detection of weed seedlings. The ability to discriminate weeds was significantly affected by the imagery spectral (type of camera), spatial (flight altitude) and temporal (the date of the study) resolutions. The colour-infrared images captured at 40 m and 50 days after sowing (date 2), when plants had 5-6 true leaves, had the highest weed detection accuracy (up to 91%). At this flight altitude, the images captured before date 2 had slightly better results than the images captured later. However, this trend changed in the visible-light images captured at 60 m and higher, which had notably better results on date 3 (57 days after sowing) because of the larger size of the weed plants. Our results showed the requirements on spectral and spatial resolutions needed to generate a suitable weed map early in the growing season, as well as the best moment for the UAV image acquisition, with the ultimate objective of applying site-specific weed management operations.

  4. Changes in respiratory function impairment following the treatment of severe pulmonary tuberculosis - limitations for the underlying COPD detection.

    Science.gov (United States)

    Radovic, Milan; Ristic, Lidija; Ciric, Zorica; Dinic-Radovic, Violeta; Stankovic, Ivana; Pejcic, Tatjana; Rancic, Milan; Bogdanovic, Dragan

    2016-01-01

    During the treatment phase of active pulmonary tuberculosis (PTB), respiratory function impairment is usually restrictive. This may become obstructive, as a PTB-associated airflow obstruction (AFO) or as a later manifestation of underlying COPD. The aim of the study was to examine the potential causes and risks for AFO development in PTB by exploring the aspects of spirometry limitations and clinical implications for the underlying COPD detection, taking into account various confounding factors. Prospective, nest case-control study on 40 new cases of PTB with initial restrictive respiratory function impairment, diagnosed and treated according to the directly observed treatment short course (DOTS) strategy. From all observed patients, 37.5% of them developed AFO upon the completion of PTB treatment, with significantly increased average of forced vital capacity (%) (Ppulmonary tuberculosis lesions (OR 1.01-1.05 for 95% CI; P=0.02) and sputum conversion rate on culture (OR 1.02-1.68 for 95% CI; P=0.04) as the most significant predictors for the risk of AFO development. AFO upon PTB treatment is a common manifestation of underlying COPD, which mostly occurs later, during the reparative processes in active PTB, even in the absence of major risk factors, such as cigarette smoking and biomass fuel dust exposure. Initial spirometry testing in patients with active PTB is not a sufficient and accurate approach in the detection of underlying COPD, which may lead to their further potential health deterioration.

  5. Advantages and Limitations of Androgen Receptor-Based Methods for Detecting Anabolic Androgenic Steroid Abuse as Performance Enhancing Drugs

    Science.gov (United States)

    Bailey, Kathy; Yazdi, Tahmineh; Masharani, Umesh; Tyrrell, Blake; Butch, Anthony; Schaufele, Fred

    2016-01-01

    Testosterone (T) and related androgens are performance enhancing drugs (PEDs) abused by some athletes to gain competitive advantage. To monitor unauthorized androgen abuse, doping control programs use mass spectrometry (MS) to detect androgens, synthetic anabolic-androgenic steroids (AASs) and their metabolites in an athlete’s urine. AASs of unknown composition will not be detected by these procedures. Since AASs achieve their anabolic effects by activating the Androgen Receptor (AR), cell-based bioassays that measure the effect of a urine sample on AR activity are under investigation as complementary, pan-androgen detection methods. We evaluated an AR BioAssay as a monitor for androgen activity in urine pre-treated with glucuronidase, which releases T from the inactive T-glucuronide that predominates in urine. AR BioAssay activity levels were expressed as ‘T-equivalent’ concentrations by comparison to a T dose response curve. The T-equivalent concentrations of androgens in the urine of hypogonadal participants supplemented with T (in whom all androgenic activity should arise from T) were quantitatively identical to the T measurements conducted by MS at the UCLA Olympic Analytical Laboratory (0.96 ± 0.22). All 17 AASs studied were active in the AR BioAssay; other steroids were inactive. 12 metabolites of 10 commonly abused AASs, which are used for MS monitoring of AAS doping because of their prolonged presence in urine, had reduced or no AR BioAssay activity. Thus, the AR BioAssay can accurately and inexpensively monitor T, but its ability to monitor urinary AASs will be limited to a period immediately following doping in which the active AASs remain intact. PMID:26998755

  6. Advantages and Limitations of Androgen Receptor-Based Methods for Detecting Anabolic Androgenic Steroid Abuse as Performance Enhancing Drugs.

    Science.gov (United States)

    Bailey, Kathy; Yazdi, Tahmineh; Masharani, Umesh; Tyrrell, Blake; Butch, Anthony; Schaufele, Fred

    2016-01-01

    Testosterone (T) and related androgens are performance enhancing drugs (PEDs) abused by some athletes to gain competitive advantage. To monitor unauthorized androgen abuse, doping control programs use mass spectrometry (MS) to detect androgens, synthetic anabolic-androgenic steroids (AASs) and their metabolites in an athlete's urine. AASs of unknown composition will not be detected by these procedures. Since AASs achieve their anabolic effects by activating the Androgen Receptor (AR), cell-based bioassays that measure the effect of a urine sample on AR activity are under investigation as complementary, pan-androgen detection methods. We evaluated an AR BioAssay as a monitor for androgen activity in urine pre-treated with glucuronidase, which releases T from the inactive T-glucuronide that predominates in urine. AR BioAssay activity levels were expressed as 'T-equivalent' concentrations by comparison to a T dose response curve. The T-equivalent concentrations of androgens in the urine of hypogonadal participants supplemented with T (in whom all androgenic activity should arise from T) were quantitatively identical to the T measurements conducted by MS at the UCLA Olympic Analytical Laboratory (0.96 ± 0.22). All 17 AASs studied were active in the AR BioAssay; other steroids were inactive. 12 metabolites of 10 commonly abused AASs, which are used for MS monitoring of AAS doping because of their prolonged presence in urine, had reduced or no AR BioAssay activity. Thus, the AR BioAssay can accurately and inexpensively monitor T, but its ability to monitor urinary AASs will be limited to a period immediately following doping in which the active AASs remain intact.

  7. Diagnostic accuracy of the detection of bone change using panoramic TMJ projection. Comparative study with limited cone-beam CT

    International Nuclear Information System (INIS)

    Araki, Kazuyuki; Okano, Tomohiro; Kataoka, Ryuta; Honda, Kazuya; Endo, Atsushi; Kaneko, Norikazu; Funahashi, Itsuo

    2008-01-01

    Panoramic temporoman joint (TMJ) projection is one of the alternative methods of conventional radiography, such as transcranial projection, for diagnosing temporomandibular joint disorder. There have been a few reports describing the diagnostic ability of this method. We evaluated the diagnostic accuracy of detecting bone change with panoramic TMJ projection. Fifty TMJs in 25 patients were examined. All TMJs were examined by panoramic TMJ projection (Hyper XF) and limited cone-beam CT (3D Accuitomo FPD; 3DX). Two observers evaluated the presence of bone change in the TMJ region using panoramic TMJ projection. One other observer evaluated the limited cone-beam CT for the presence and the pattern of bone changes in the TMJ region as the gold standard. Panoramic TMJ findings were evaluated with regard to sensitivity, specificity, and accuracy. Sensitivity, specificity and accuracy of the panoramic TMJ projection were 0.86, 0.76, and 0.82, respectively. These results and those of previous reports on other radiographic methods for TMJ suggest that panoramic TMJ projection is a useful method of screening for bone change due to TMJ disorder. (author)

  8. Employment effects of minimum wages

    OpenAIRE

    Neumark, David

    2014-01-01

    The potential benefits of higher minimum wages come from the higher wages for affected workers, some of whom are in low-income families. The potential downside is that a higher minimum wage may discourage employers from using the low-wage, low-skill workers that minimum wages are intended to help. Research findings are not unanimous, but evidence from many countries suggests that minimum wages reduce the jobs available to low-skill workers.

  9. 75 FR 6151 - Minimum Capital

    Science.gov (United States)

    2010-02-08

    ... capital and reserve requirements to be issued by order or regulation with respect to a product or activity... minimum capital requirements. Section 1362(a) establishes a minimum capital level for the Enterprises... entities required under this section.\\6\\ \\3\\ The Bank Act's current minimum capital requirements apply to...

  10. Risk control and the minimum significant risk

    International Nuclear Information System (INIS)

    Seiler, F.A.; Alvarez, J.L.

    1996-01-01

    Risk management implies that the risk manager can, by his actions, exercise at least a modicum of control over the risk in question. In the terminology of control theory, a management action is a control signal imposed as feedback on the system to bring about a desired change in the state of the system. In the terminology of risk management, an action is taken to bring a predicted risk to lower values. Even if it is assumed that the management action taken is 100% effective and that the projected risk reduction is infinitely well known, there is a lower limit to the desired effects that can be achieved. It is based on the fact that all risks, such as the incidence of cancer, exhibit a degree of variability due to a number of extraneous factors such as age at exposure, sex, location, and some lifestyle parameters such as smoking or the consumption of alcohol. If the control signal is much smaller than the variability of the risk, the signal is lost in the noise and control is lost. This defines a minimum controllable risk based on the variability of the risk over the population considered. This quantity is the counterpart of the minimum significant risk which is defined by the uncertainties of the risk model. Both the minimum controllable risk and the minimum significant risk are evaluated for radiation carcinogenesis and are shown to be of the same order of magnitude. For a realistic management action, the assumptions of perfectly effective action and perfect model prediction made above have to be dropped, resulting in an effective minimum controllable risk which is determined by both risk limits. Any action below that effective limit is futile, but it is also unethical due to the ethical requirement of doing more good than harm. Finally, some implications of the effective minimum controllable risk on the use of the ALARA principle and on the evaluation of remedial action goals are presented

  11. Measurement Error, Reliability, and Minimum Detectable Change in the Mini-Mental State Examination, Montreal Cognitive Assessment, and Color Trails Test among Community Living Middle-Aged and Older Adults.

    Science.gov (United States)

    Feeney, Joanne; Savva, George M; O'Regan, Claire; King-Kallimanis, Bellinda; Cronin, Hilary; Kenny, Rose Anne

    2016-05-31

    Knowing the reliability of cognitive tests, particularly those commonly used in clinical practice, is important in order to interpret the clinical significance of a change in performance or a low score on a single test. To report the intra-class correlation (ICC), standard error of measurement (SEM) and minimum detectable change (MDC) for the Mini-Mental State Examination (MMSE), Montreal Cognitive Assessment (MoCA), and Color Trails Test (CTT) among community dwelling older adults. 130 participants aged 55 and older without severe cognitive impairment underwent two cognitive assessments between two and four months apart. Half the group changed rater between assessments and half changed time of day. Mean (standard deviation) MMSE was 28.1 (2.1) at baseline and 28.4 (2.1) at repeat. Mean (SD) MoCA increased from 24.8 (3.6) to 25.2 (3.6). There was a rater effect on CTT, but not on the MMSE or MoCA. The SEM of the MMSE was 1.0, leading to an MDC (based on a 95% confidence interval) of 3 points. The SEM of the MoCA was 1.5, implying an MDC95 of 4 points. MoCA (ICC = 0.81) was more reliable than MMSE (ICC = 0.75), but all tests examined showed substantial within-patient variation. An individual's score would have to change by greater than or equal to 3 points on the MMSE and 4 points on the MoCA for the rater to be confident that the change was not due to measurement error. This has important implications for epidemiologists and clinicians in dementia screening and diagnosis.

  12. The Fatty Liver Index has limited utility for the detection and quantification of hepatic steatosis in obese patients.

    Science.gov (United States)

    Borman, Meredith A; Ladak, Farah; Crotty, Pam; Pollett, Aaron; Kirsch, Richard; Pomier-Layrargues, Gilles; Beaton, Melanie; Duarte-Rojo, Andres; Elkashab, Magdy; Myers, Robert P

    2013-06-01

    Noninvasive tools for the detection of hepatic steatosis are needed. The Fatty Liver Index (FLI), which includes body mass index (BMI), waist circumference, triglycerides, and γ-glutamyl-transferase, has been proposed as a screening tool for fatty liver. Our objective was to validate the FLI for the detection and quantification of hepatic steatosis in an obese population. Patients with chronic liver disease and BMI ≥ 28 kg/m(2) underwent liver biopsy and FLI determination. FLI performance for diagnosing steatosis compared with biopsy was assessed using areas under receiver operating characteristic curves (AUROCs), and a novel model for the prediction of significant steatosis (≥5 %) was derived. Among 250 included patients, 65 % were male, and the median BMI was 33 kg/m(2); 48 % had nonalcoholic fatty liver disease, and 77 % had significant (≥5 %) steatosis. The FLI was weakly correlated with the percentage (ρ = 0.25, p = 0.0001) and grade of steatosis (ρ = 0.28, p steatosis (91 vs. 80 with steatosis; p = 0.0001) and the AUROC for this outcome was 0.67 (95 % CI 0.59-0.76). At an optimal FLI cut-off of 79, the FLI was 81 % sensitive and 49 % specific, and had positive and negative predictive values of 84 and 43 %, respectively. A novel index including triglycerides, glucose, alkaline phosphatase, and BMI outperformed the FLI for predicting significant steatosis [AUROCs 0.78 vs. 0.68; p = 0.009 (n = 247)]. In obese patients, the FLI is a poor predictor of significant steatosis and has limited utility for steatosis quantification compared with liver histology. A novel index including triglycerides, glucose, alkaline phosphatase, and BMI may be useful, but requires validation.

  13. SERS activity with tenfold detection limit optimization on a type of nanoporous AAO-based complex multilayer substrate

    Science.gov (United States)

    Sui, Chaofan; Wang, Kaige; Wang, Shuang; Ren, Junying; Bai, Xiaohong; Bai, Jintao

    2016-03-01

    Most of SERS applications are constricted by heterogeneous hotspots and aggregates of nanostructure, which result in low sensitivity and poor reproducibility of characteristic signals. This work intends to introduce SERS properties of a type of SERS-active substrate, Au-CuCl2-AAO, which is innovatively developed on a porous anodic alumina oxide (AAO) template. Spectral measuring results of Rhodamine 6G (R6G) on this substrate optimized by controlling morphology and gold thickness showed that enhancement factor (2.30 × 107) and detection limit (10-10 M) were both improved and represented better performance than its template AAO. Homogenous hot spots across the region of interest were achieved by scanning SERS intensity distribution for the band at 1505 cm-1 in 5 × 5 μm2 area. Furthermore, the promising SERS activity of the flower-patterned substrate was theoretically explained through simulation of the electromagnetic field distribution. In addition, this SERS substrate is proposed for applications within the field of chemical and biochemical analyses.Most of SERS applications are constricted by heterogeneous hotspots and aggregates of nanostructure, which result in low sensitivity and poor reproducibility of characteristic signals. This work intends to introduce SERS properties of a type of SERS-active substrate, Au-CuCl2-AAO, which is innovatively developed on a porous anodic alumina oxide (AAO) template. Spectral measuring results of Rhodamine 6G (R6G) on this substrate optimized by controlling morphology and gold thickness showed that enhancement factor (2.30 × 107) and detection limit (10-10 M) were both improved and represented better performance than its template AAO. Homogenous hot spots across the region of interest were achieved by scanning SERS intensity distribution for the band at 1505 cm-1 in 5 × 5 μm2 area. Furthermore, the promising SERS activity of the flower-patterned substrate was theoretically explained through simulation of the

  14. Multiplex real-time quantitative PCR, microscopy and rapid diagnostic immuno-chromatographic tests for the detection of Plasmodium spp: performance, limit of detection analysis and quality assurance

    Directory of Open Access Journals (Sweden)

    Ralevski Filip

    2009-12-01

    Full Text Available Abstract Background Accurate laboratory diagnosis of malaria species in returning travelers is paramount in the treatment of this potentially fatal infectious disease. Materials and methods A total of 466 blood specimens from returning travelers to Africa, Asia, and South/Central America with suspected malaria infection were collected between 2007 and 2009 at the reference public health laboratory. These specimens were assessed by reference microscopy, multipex real-time quantitative polymerase chain reaction (QPCR, and two rapid diagnostic immuno-chromatographic tests (ICT in a blinded manner. Key clinical laboratory parameters such as limit of detection (LOD analysis on clinical specimens by parasite stage, inter-reader variability of ICTs, staffing implications, quality assurance and cost analysis were evaluated. Results QPCR is the most analytically sensitive method (sensitivity 99.41%, followed by CARESTART (sensitivity 88.24%, and BINAXNOW (sensitivity 86.47% for the diagnosis of malaria in returning travelers when compared to reference microscopy. However, microscopy was unable to specifically identify Plasmodia spp. in 18 out of 170 positive samples by QPCR. Moreover, the 17 samples that were negative by microscopy and positive by QPCR were also positive by ICTs. Quality assurance was achieved for QPCR by exchanging a blinded proficiency panel with another reference laboratory. The Kappa value of inter-reader variability among three readers for BINAXNOW and CARESTART was calculated to be 0.872 and 0.898 respectively. Serial dilution studies demonstrated that the QPCR cycle threshold correlates linearly with parasitemia (R2 = 0.9746 in a clinically relevant dynamic range and retains a LOD of 11 rDNA copies/μl for P. falciparum, which was several log lower than reference microscopy and ICTs. LOD for QPCR is affected not only by parasitemia but the parasite stage distribution of each clinical specimen. QPCR was approximately 6-fold more

  15. Detecting Ebola with limited laboratory access in the Democratic Republic of Congo: evaluation of a clinical passive surveillance reporting system.

    Science.gov (United States)

    Ashbaugh, Hayley R; Kuang, Brandon; Gadoth, Adva; Alfonso, Vivian H; Mukadi, Patrick; Doshi, Reena H; Hoff, Nicole A; Sinai, Cyrus; Mossoko, Mathias; Kebela, Benoit Ilunga; Muyembe, Jean-Jacques; Wemakoy, Emile Okitolonda; Rimoin, Anne W

    2017-09-01

    Ebola virus disease (EVD) can be clinically severe and highly fatal, making surveillance efforts for early disease detection of paramount importance. In areas with limited access to laboratory testing, the Integrated Disease Surveillance and Response (IDSR) strategy in the Democratic Republic of Congo (DRC) may be a vital tool in improving outbreak response. Using DRC IDSR data from the nation's four EVD outbreak periods from 2007-2014, we assessed trends of Viral Hemorrhagic Fever (VHF) and EVD differential diagnoses reportable through IDSR. With official case counts from active surveillance of EVD outbreaks, we assessed accuracy of reporting through the IDSR passive surveillance system. Although the active and passive surveillance represent distinct sets of data, the two were correlated, suggesting that passive surveillance based only on clinical evaluation may be a useful predictor of true cases prior to laboratory confirmation. There were 438 suspect VHF cases reported through the IDSR system and 416 EVD cases officially recorded across the outbreaks examined. Although collected prior to official active surveillance cases, case reporting through the IDSR during the 2007, 2008 and 2012 outbreaks coincided with official EVD epidemic curves. Additionally, all outbreak areas experienced increases in suspected cases for both malaria and typhoid fever during EVD outbreaks, underscoring the importance of training health care workers in recognising EVD differential diagnoses and the potential for co-morbidities. © 2017 John Wiley & Sons Ltd.

  16. Role, limitations and place of medical imaging in the prevention, screening and early detection of breast cancer

    International Nuclear Information System (INIS)

    Lamarque, J.L.; Pujol, J.; Rodiere, M.J.; Laurent, J.C.; Prat, X.; Martin, J.M.; Khodr, A.

    1986-01-01

    For prevention and screening of breast cancer the triad of CLINICAL SIGNS - RADIOLOGY - CYTOLOGY constitutes the most efficient and least costly method. If properly done, clinical examinations can predict the benignity or malignancy of a lesion with an accuracy rate of 80%. While self-examinations are of interest, they cannot replace a proper medical examination. Self-palpation may cause anxiety and cancerophobia both of which may have an as yet poorly understood effect on benign mastopathis. Mammography is currently the most reliable and specific imaging technique. While it can identify stage 0 lesions, it reaches its technical limits in patients with dense breast tissue. It is reserved for high-risk patients. Aspiration cytology is an excellent technique for evaluating areas with a diameter of 1 cm and more. While it cannot diagnose breast cancers in a very early stage, it helps avoid delays in the diagnosis by providing supportive evidence for radiological and clinical findings. Recent pathologic studies showed cancers to develop most often in the presence of proliferative epithelial lesions. This would seem to suggest the need for cytohistologic typing, which can be expected to pick out high-risk patients effectively, to ensure a truly early detection and diagnosis of cancer and to provide for a meaningful prevention. (Author)

  17. Evaluation of the odd-even effect in limits of detection for electron microprobe analysis of natural minerals

    Energy Technology Data Exchange (ETDEWEB)

    Verma, Surendra P., E-mail: spv@cie.unam.mx [Departamento de Sistemas Energeticos, Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Priv. Xochicalco s/no., Col Centro, A.P. 34, Temixco, Mor. 62580 (Mexico); Pandarinath, Kailasa [Departamento de Sistemas Energeticos, Centro de Investigacion en Energia, Universidad Nacional Autonoma de Mexico, Priv. Xochicalco s/no., Col Centro, A.P. 34, Temixco, Mor. 62580 (Mexico); Velasco-Tapia, Fernando [Facultad de Ciencias de la Tierra, Universidad Autonoma de Nuevo Leon, Carretera Linares-Cerro Prieto km. 8, Linares, N.L. 67700 (Mexico); Rodriguez-Rios, Rodolfo [Facultad de Ingenieria e Instituto de Geologia, Universidad Autonoma de San Luis Potosi, Av. Dr. Manuel Nava No. 8, Zona Universitaria, San Luis Potosi, S.L.P. 78240 (Mexico)

    2009-04-13

    Limit of detection (LOD), being a fundamental quality parameter for analytical techniques, has been recently investigated and a systematic behavior has been observed for most odd-even element pairs for many techniques. However, to the best of our knowledge very few LOD data are available in published literature for electron microprobe analysis; these consist of three papers, two being on rare-earth elements and the third covering a large number of elements of atomic number between 21 and 92. These data confirm the systematic behavior of LODs for many odd-even pairs. To initiate to full this gap, we determined LODs for several major rock-forming chemical elements from Na to Fe with atomic numbers between 11 and 26, during the microprobe analysis of common minerals (olivine, plagioclase, pyroxene, amphibole, quartz, and opaques) in volcanic rocks. The odd-even effect of nuclear stability seems to be present in LOD data for most odd-even pairs investigated. Nevertheless, the experimental strategy concerning the reference materials, calibration procedure, and blank measurements, should be substantially modified to better evaluate the systematic behavior of LOD values in microprobe analysis.

  18. Evaluation of the odd-even effect in limits of detection for electron microprobe analysis of natural minerals

    International Nuclear Information System (INIS)

    Verma, Surendra P.; Pandarinath, Kailasa; Velasco-Tapia, Fernando; Rodriguez-Rios, Rodolfo

    2009-01-01

    Limit of detection (LOD), being a fundamental quality parameter for analytical techniques, has been recently investigated and a systematic behavior has been observed for most odd-even element pairs for many techniques. However, to the best of our knowledge very few LOD data are available in published literature for electron microprobe analysis; these consist of three papers, two being on rare-earth elements and the third covering a large number of elements of atomic number between 21 and 92. These data confirm the systematic behavior of LODs for many odd-even pairs. To initiate to full this gap, we determined LODs for several major rock-forming chemical elements from Na to Fe with atomic numbers between 11 and 26, during the microprobe analysis of common minerals (olivine, plagioclase, pyroxene, amphibole, quartz, and opaques) in volcanic rocks. The odd-even effect of nuclear stability seems to be present in LOD data for most odd-even pairs investigated. Nevertheless, the experimental strategy concerning the reference materials, calibration procedure, and blank measurements, should be substantially modified to better evaluate the systematic behavior of LOD values in microprobe analysis.

  19. Morpholinoethanesulfonic acid-based buffer system for improved detection limit and stability of the fluoride ion selective electrode

    International Nuclear Information System (INIS)

    Fouskaki, M.; Sotiropoulou, S.; Koci, M.; Chaniotakis, N.A.

    2002-01-01

    The zwitterionic morpholinoethanesulfonic acid (MES) is used as the basis for the development of a new total ionic strength adjustor buffer system for improving the analytical characteristics of fluoride sensor. Impedance analysis, atomic force microscopy (AFM) and dissolution studies of the LaF 3 crystal, together with the potential stability and sensor sensitivity over time have aided in the elucidation of the processes that take place at the surface of the LaF 3 crystal, that seem to determine the sensor behaviour. Even though AFM analysis shows that both buffers used (MES or acetate) cause a similar increase in surface roughness, the data from the other studies suggest that in the first case there is a reversible ion exchange process at the interface, while in the second case this process is irreversible, leading to fast poisoning of the crystal surface. The use of 0.5 M MES and NaCl buffer adjusted to pH 5.50 allows for the continuous operation of the sensor under flow injection analysis conditions for at least 5 days with sensitivity of 60 mV per decade [F - ], detection limit of 2.1x10 -7 M [F - ] and fast response time

  20. ON COMPUTING UPPER LIMITS TO SOURCE INTENSITIES

    International Nuclear Information System (INIS)

    Kashyap, Vinay L.; Siemiginowska, Aneta; Van Dyk, David A.; Xu Jin; Connors, Alanna; Freeman, Peter E.; Zezas, Andreas

    2010-01-01

    A common problem in astrophysics is determining how bright a source could be and still not be detected in an observation. Despite the simplicity with which the problem can be stated, the solution involves complicated statistical issues that require careful analysis. In contrast to the more familiar confidence bound, this concept has never been formally analyzed, leading to a great variety of often ad hoc solutions. Here we formulate and describe the problem in a self-consistent manner. Detection significance is usually defined by the acceptable proportion of false positives (background fluctuations that are claimed as detections, or Type I error), and we invoke the complementary concept of false negatives (real sources that go undetected, or Type II error), based on the statistical power of a test, to compute an upper limit to the detectable source intensity. To determine the minimum intensity that a source must have for it to be detected, we first define a detection threshold and then compute the probabilities of detecting sources of various intensities at the given threshold. The intensity that corresponds to the specified Type II error probability defines that minimum intensity and is identified as the upper limit. Thus, an upper limit is a characteristic of the detection procedure rather than the strength of any particular source. It should not be confused with confidence intervals or other estimates of source intensity. This is particularly important given the large number of catalogs that are being generated from increasingly sensitive surveys. We discuss, with examples, the differences between these upper limits and confidence bounds. Both measures are useful quantities that should be reported in order to extract the most science from catalogs, though they answer different statistical questions: an upper bound describes an inference range on the source intensity, while an upper limit calibrates the detection process. We provide a recipe for computing upper

  1. Computation of distribution of minimum resolution for log-normal distribution of chromatographic peak heights.

    Science.gov (United States)

    Davis, Joe M

    2011-10-28

    General equations are derived for the distribution of minimum resolution between two chromatographic peaks, when peak heights in a multi-component chromatogram follow a continuous statistical distribution. The derivation draws on published theory by relating the area under the distribution of minimum resolution to the area under the distribution of the ratio of peak heights, which in turn is derived from the peak-height distribution. Two procedures are proposed for the equations' numerical solution. The procedures are applied to the log-normal distribution, which recently was reported to describe the distribution of component concentrations in three complex natural mixtures. For published statistical parameters of these mixtures, the distribution of minimum resolution is similar to that for the commonly assumed exponential distribution of peak heights used in statistical-overlap theory. However, these two distributions of minimum resolution can differ markedly, depending on the scale parameter of the log-normal distribution. Theory for the computation of the distribution of minimum resolution is extended to other cases of interest. With the log-normal distribution of peak heights as an example, the distribution of minimum resolution is computed when small peaks are lost due to noise or detection limits, and when the height of at least one peak is less than an upper limit. The distribution of minimum resolution shifts slightly to lower resolution values in the first case and to markedly larger resolution values in the second one. The theory and numerical procedure are confirmed by Monte Carlo simulation. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.

    Science.gov (United States)

    Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf

    2017-12-01

    The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally

  3. Multivariate estimation of the limit of detection by orthogonal partial least squares in temperature-modulated MOX sensors.

    Science.gov (United States)

    Burgués, Javier; Marco, Santiago

    2018-08-17

    Metal oxide semiconductor (MOX) sensors are usually temperature-modulated and calibrated with multivariate models such as partial least squares (PLS) to increase the inherent low selectivity of this technology. The multivariate sensor response patterns exhibit heteroscedastic and correlated noise, which suggests that maximum likelihood methods should outperform PLS. One contribution of this paper is the comparison between PLS and maximum likelihood principal components regression (MLPCR) in MOX sensors. PLS is often criticized by the lack of interpretability when the model complexity increases beyond the chemical rank of the problem. This happens in MOX sensors due to cross-sensitivities to interferences, such as temperature or humidity and non-linearity. Additionally, the estimation of fundamental figures of merit, such as the limit of detection (LOD), is still not standardized in multivariate models. Orthogonalization methods, such as orthogonal projection to latent structures (O-PLS), have been successfully applied in other fields to reduce the complexity of PLS models. In this work, we propose a LOD estimation method based on applying the well-accepted univariate LOD formulas to the scores of the first component of an orthogonal PLS model. The resulting LOD is compared to the multivariate LOD range derived from error-propagation. The methodology is applied to data extracted from temperature-modulated MOX sensors (FIS SB-500-12 and Figaro TGS 3870-A04), aiming at the detection of low concentrations of carbon monoxide in the presence of uncontrolled humidity (chemical noise). We found that PLS models were simpler and more accurate than MLPCR models. Average LOD values of 0.79 ppm (FIS) and 1.06 ppm (Figaro) were found using the approach described in this paper. These values were contained within the LOD ranges obtained with the error-propagation approach. The mean LOD increased to 1.13 ppm (FIS) and 1.59 ppm (Figaro) when considering validation samples

  4. Methodology applied by the Petroleum, Natural Gas and Bio fuels National Agency for detection of cartels - their limits and perspectives; Metodology adotada pela Agencia Nacional do Petroleo, Gas Natural e Biocombustiveis para detectecao de carteis - seus limites e perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Pedra, Douglas Pereira; Sales, Orlando de Araujo Vilela; Baran, Patricia Huguenin; Paiva, Rodrigo Milao de [Agencia Nacional do Petroleo, Gas Natural e Biocombustiveis (ANP), Rio de Janeiro, RJ (Brazil). Regulacao de Petroleo, seus Derivados, Alcool Combustivel e Gas Natural; Bicalho, Lucia Maria de Oliveira Navegantes [Universidade Federal do Rio de Janeiro (PPE/COPPE/UFRJ), RJ (Brazil). Coordenacao dos Programas de Pos-Graduacao de Engenharia. Programa de Planejamento Energetico

    2010-07-01

    This paper presents the present methodology used by the Defense Competition Coordination of the Petroleum National Agency for detection of vestiges of cartels in the Brazilian fuel market, their limits, in view of the instruments presently at the disposal of the Agency and perspectives of modification from the eventual availability of new instruments.

  5. Interaction of cosmic ray muons with spent nuclear fuel dry casks and determination of lower detection limit

    Energy Technology Data Exchange (ETDEWEB)

    Chatzidakis, S., E-mail: schatzid@purdue.edu; Choi, C.K.; Tsoukalas, L.H.

    2016-08-21

    The potential non-proliferation monitoring of spent nuclear fuel sealed in dry casks interacting continuously with the naturally generated cosmic ray muons is investigated. Treatments on the muon RMS scattering angle by Moliere, Rossi-Greisen, Highland and, Lynch-Dahl were analyzed and compared with simplified Monte Carlo simulations. The Lynch-Dahl expression has the lowest error and appears to be appropriate when performing conceptual calculations for high-Z, thick targets such as dry casks. The GEANT4 Monte Carlo code was used to simulate dry casks with various fuel loadings and scattering variance estimates for each case were obtained. The scattering variance estimation was shown to be unbiased and using Chebyshev's inequality, it was found that 10{sup 6} muons will provide estimates of the scattering variances that are within 1% of the true value at a 99% confidence level. These estimates were used as reference values to calculate scattering distributions and evaluate the asymptotic behavior for small variations on fuel loading. It is shown that the scattering distributions between a fully loaded dry cask and one with a fuel assembly missing initially overlap significantly but their distance eventually increases with increasing number of muons. One missing fuel assembly can be distinguished from a fully loaded cask with a small overlapping between the distributions which is the case of 100,000 muons. This indicates that the removal of a standard fuel assembly can be identified using muons providing that enough muons are collected. A Bayesian algorithm was developed to classify dry casks and provide a decision rule that minimizes the risk of making an incorrect decision. The algorithm performance was evaluated and the lower detection limit was determined.

  6. The Effect of Minimum Wage Rates on High School Completion

    Science.gov (United States)

    Warren, John Robert; Hamrock, Caitlin

    2010-01-01

    Does increasing the minimum wage reduce the high school completion rate? Previous research has suffered from (1. narrow time horizons, (2. potentially inadequate measures of states' high school completion rates, and (3. potentially inadequate measures of minimum wage rates. Overcoming each of these limitations, we analyze the impact of changes in…

  7. Minimum risk trigger indices

    International Nuclear Information System (INIS)

    Tingey, F.H.

    1979-01-01

    A viable safeguards system includes among other things the development and use of indices which trigger various courses of action. The usual limit of error calculation provides such an index. The classical approach is one of constructing tests which, under certain assumptions, make the likelihood of a false alarm small. Of concern also is the test's failure to indicate a loss (diversion) when in fact one has occurred. Since false alarms are usually costly and losses both costly and of extreme strategic sinificance, there remains the task of balancing the probability of false alarm and its consequences against the probability of undetected loss and its consequences. The application of other than classical hypothesis testing procedures are considered in this paper. Using various consequence models, trigger indices are derived which have certain optimum properties. Application of the techniques would enhance the material control function

  8. Method to Solve the Problem of the Radioactivity Detection in Environmental Samples. Characteristic Limits; Metodos para la Resolucion del Problema de la Detecfcion de Radiactividad en Muestras Ambientales. Limites Caracteristicos

    Energy Technology Data Exchange (ETDEWEB)

    Gasco, C.; Martinez, M.; Heras, M.

    2009-07-21

    The problem of the detection or when the radioactivity can be considered as higher than the background using different measurement techniques has been the objective of several statistical studies and controversies. The detection limit and the critical limit were studied by Currie in year 1968 and used by radiochemistry laboratories considering different ways of calculation that introduced confusion and not correct implementations. In the last few years, and due to the increasing number of standardization processes on the field of radioactivity and accreditation, several international institutions have chosen to unify the criteria for using common determination of detection limits. The most used methods are those developed by MARLAP and International Standard Organization ISO (Standard-11929). In this report are summarised both standards doing a comparative study and giving some examples of how to apply these limits. In same cases, little differences in the uncertainty calculation have been observed but the final results have been concordant. A deeply study of these standards can be done consulting the web page of the American Labs that developed MARLAP or buying the original ISO standard ISO-11929 recently approved (2009). (Author) 17 refs.

  9. Quantifying Environmental Limiting Factors on Tree Cover Using Geospatial Data

    NARCIS (Netherlands)

    Greenberg, Jonathan; Ferreira Dos Santos, Maria Joao; Dobrowski, Solomon; Vanderbilt, Vern; Ustin, Susan

    2015-01-01

    Environmental limiting factors (ELFs) are the thresholds that determine the maximum or minimum biological response for a given suite of environmental conditions. We asked the following questions: 1) Can we detect ELFs on percent tree cover across the eastern slopes of the Lake Tahoe Basin, NV? 2)

  10. Methane Flux Estimation from Point Sources using GOSAT Target Observation: Detection Limit and Improvements with Next Generation Instruments

    Science.gov (United States)

    Kuze, A.; Suto, H.; Kataoka, F.; Shiomi, K.; Kondo, Y.; Crisp, D.; Butz, A.

    2017-12-01

    Atmospheric methane (CH4) has an important role in global radiative forcing of climate but its emission estimates have larger uncertainties than carbon dioxide (CO2). The area of anthropogenic emission sources is usually much smaller than 100 km2. The Thermal And Near infrared Sensor for carbon Observation Fourier-Transform Spectrometer (TANSO-FTS) onboard the Greenhouse gases Observing SATellite (GOSAT) has measured CO2 and CH4 column density using sun light reflected from the earth's surface. It has an agile pointing system and its footprint can cover 87-km2 with a single detector. By specifying pointing angles and observation time for every orbit, TANSO-FTS can target various CH4 point sources together with reference points every 3 day over years. We selected a reference point that represents CH4 background density before or after targeting a point source. By combining satellite-measured enhancement of the CH4 column density and surface measured wind data or estimates from the Weather Research and Forecasting (WRF) model, we estimated CH4emission amounts. Here, we picked up two sites in the US West Coast, where clear sky frequency is high and a series of data are available. The natural gas leak at Aliso Canyon showed a large enhancement and its decrease with time since the initial blowout. We present time series of flux estimation assuming the source is single point without influx. The observation of the cattle feedlot in Chino, California has weather station within the TANSO-FTS footprint. The wind speed is monitored continuously and the wind direction is stable at the time of GOSAT overpass. The large TANSO-FTS footprint and strong wind decreases enhancement below noise level. Weak wind shows enhancements in CH4, but the velocity data have large uncertainties. We show the detection limit of single samples and how to reduce uncertainty using time series of satellite data. We will propose that the next generation instruments for accurate anthropogenic CO2 and CH

  11. Comparison of detection limits in environmental analysis--is it possible? An approach on quality assurance in the lower working range by verification.

    Science.gov (United States)

    Geiss, S; Einax, J W

    2001-07-01

    Detection limit, reporting limit and limit of quantitation are analytical parameters which describe the power of analytical methods. These parameters are used for internal quality assurance and externally for competing, especially in the case of trace analysis in environmental compartments. The wide variety of possibilities for computing or obtaining these measures in literature and in legislative rules makes any comparison difficult. Additionally, a host of terms have been used within the analytical community to describe detection and quantitation capabilities. Without trying to create an order for the variety of terms, this paper is aimed at providing a practical proposal for answering the main questions for the analysts concerning quality measures above. These main questions and related parameters were explained and graphically demonstrated. Estimation and verification of these parameters are the two steps to get real measures. A rule for a practical verification is given in a table, where the analyst can read out what to measure, what to estimate and which criteria have to be fulfilled. In this manner verified parameters detection limit, reporting limit and limit of quantitation now are comparable and the analyst himself is responsible to the unambiguity and reliability of these measures.

  12. Partial Least Squares Calibration Modeling Towards the Multivariate Limit of Detection for Enriched Isotopic Mixtures via Laser Ablation Molecular Isotopic Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Candace [Florida Agriculture & Mechanic Univ.; Profeta, Luisa [Alakai Defense Systems, Inc.; Akpovo, Codjo [Florida Agriculture & Mechanic Univ.; Stowe, Ashley [Y-12 National Security Complex, Oak Ridge, TN (United States); Johnson, Lewis [Florida Agriculture & Mechanic Univ.

    2017-10-09

    The psuedo univariate limit of detection was calculated to compare to the multivariate interval. ompared with results from the psuedounivariate LOD, the multivariate LOD includes other factors (i.e. signal uncertainties) and the reveals the significance in creating models that not only use the analyte’s emission line but also its entire molecular spectra.

  13. DETERMINATION OF LIMIT DETECTION OF THE ELEMENTS N, P, K, Si, Al, Fe, Cu, Cd, WITH FAST NEUTRON ACTIVATION USING NEUTRON GENERATOR

    Directory of Open Access Journals (Sweden)

    Sunardi Sunardi

    2010-06-01

    Full Text Available Determination of limit detection of the elements N, P, K, Si, Al, Fe, Cu, Cd, with fast neutron activation using neutron generator has been done.  Samples prepared from SRM 2704, N, P, K elements from MERCK, Cu, Cd, Al from activation foil made in San Carlos, weighted and packed for certain weight then iradiated during 30 minutes with 14 MeV fast neutron using the neutron generator and then counted with gamma spectrometry (accuspec.  At this research condition of neutron generator was set at current 1 mA that produced neutron flux about 5,47.107 n/cm2.s and  experimental result shown that the limit detection for the elements N, P, K, Si, Al, Fe, Cu, Cd are  2,44 ppm, 1,88 ppm, 2,15 ppm, 1,44 ppm, 1,26 ppm, 1,35 ppm, 1,05 ppm, 2,99 ppm, respectively.  The data  indicate that the limit detection or sensitivity of appliance of neutron generator to analyze the element is very good, which is feasible to get accreditation AANC laboratory using neutron generator.   Keywords: limit detection, AANC, neutron generator

  14. A need for standardization in drinking water analysis – an investigation of DNA extraction procedure, primer choice and detection limit of 16S rRNA amplicon sequencing

    DEFF Research Database (Denmark)

    Brandt, Jakob; Nielsen, Per Halkjær; Albertsen, Mads

    have been made to illuminate the effects specifically related to bacterial communities in drinking water. In this study, we investigated the impact of the DNA extraction and primer choice on the observed community structure, and we also estimated the detection limit of the 16S rRNA amplicon sequencing...

  15. Photoinduced triplet-state electron transfer of platinum porphyrin: a one-step direct method for sensing iodide with an unprecedented detection limit

    KAUST Repository

    Masih, Dilshad; Aly, Shawkat Mohammede; Alarousu, Erkki; Mohammed, Omar F.

    2015-01-01

    previously unattained detection limit of 1 × 10−12 M) and economical method for the determination of iodide. To fully understand the reaction mechanism responsible for the phosphorescence quenching process, we have employed cutting-edge time-resolved laser

  16. Detection limits for close eclipsing and transiting sub-stellar and planetary companions to white dwarfs in the WASP survey

    OpenAIRE

    Faedi, F.; West, R. G.; Burleigh, M. R.; Goad, M. R.; Hebb, L.

    2010-01-01

    We have performed extensive simulations to explore the possibility of detecting eclipses and transits of close, sub-stellar and planetary companions to white dwarfs in WASP light-curves. Our simulations cover companions $\\sim0.3\\Re

  17. Limited diagnostic capacities of two commercial assays for the detection of Leptospira immunoglobulin M antibodies in Laos

    NARCIS (Netherlands)

    Blacksell, Stuart D.; Smythe, Lee; Phetsouvanh, Rattanaphone; Dohnt, Michael; Hartskeerl, Rudy; SymondS, Meegan; Slack, Andrew; Vongsouvath, Manivanh; Davong, Viengmone; Lattana, Olay; Phongmany, Simmaly; Keolouangkot, Valy; White, Nicholas J.; Day, Nicholas P. J.; Newton, Paul N.

    2006-01-01

    The diagnostic utility of immunochromatographic (Leptotek) and enzyme-linked immunosorbent assay (ELISA; Panbio) tests for the detection of Leptospira immunoglobulin M antibodies was assessed in febrile adults admitted in Vientiane, Laos. Both tests demonstrated poor diagnostic accuracy using

  18. Installation of high-resolution ERDA in UTTAC at the University of Tsukuba: Determination of the energy resolution and the detection limit for hydrogen

    Energy Technology Data Exchange (ETDEWEB)

    Sekiba, D., E-mail: sekiba@tac.tsukuba.ac.jp [Institute of Applied Physics, University of Tsukuba, Tennodai 1-1-1, Tsukuba, Ibaraki 305-8573 (Japan); University of Tsukuba, Tandem Accelerator Complex (UTTAC), Tennodai 1-1-1, Tsukuba, Ibaraki 305-8577 (Japan); Chito, K.; Harayama, I. [Institute of Applied Physics, University of Tsukuba, Tennodai 1-1-1, Tsukuba, Ibaraki 305-8573 (Japan); Watahiki, Y.; Ishii, S. [University of Tsukuba, Tandem Accelerator Complex (UTTAC), Tennodai 1-1-1, Tsukuba, Ibaraki 305-8577 (Japan); Ozeki, K. [Department of Mechanical Engineering, Ibaraki University, Nakanarusawa 4-12-1, Hitachi, Ibaraki 316-8511 (Japan)

    2017-06-15

    A newly developed high-resolution elastic recoil detection analysis (HERDA) system installed at the 1 MV Tandetron in UTTAC at the University of Tsukuba is introduced. The effective solid angle of detector, energy resolution and detection limit for hydrogen are, for the first time, determined quantitatively by the measurements on an a-C:H (and D) film deposited on a Si substrate. In the case of a 500 keV {sup 16}O{sup +} as the incident beam, an energy resolution of ∼0.45 keV and a detection limit of ∼3.8 × 10{sup 20} atoms/cm{sup 3} (∼0.18 at.%) with a data acquisition time of ∼310 s are derived.

  19. Limited copy number-high resolution melting (LCN-HRM) enables the detection and identification by sequencing of low level mutations in cancer biopsies.

    Science.gov (United States)

    Do, Hongdo; Dobrovic, Alexander

    2009-10-08

    Mutation detection in clinical tumour samples is challenging when the proportion of tumour cells, and thus mutant alleles, is low. The limited sensitivity of conventional sequencing necessitates the adoption of more sensitive approaches. High resolution melting (HRM) is more sensitive than sequencing but identification of the mutation is desirable, particularly when it is important to discriminate false positives due to PCR errors or template degradation from true mutations.We thus developed limited copy number - high resolution melting (LCN-HRM) which applies limiting dilution to HRM. Multiple replicate reactions with a limited number of target sequences per reaction allow low level mutations to be detected. The dilutions used (based on Ct values) are chosen such that mutations, if present, can be detected by the direct sequencing of amplicons with aberrant melting patterns. Using cell lines heterozygous for mutations, we found that the mutations were not readily detected when they comprised 10% of total alleles (20% tumour cells) by sequencing, whereas they were readily detectable at 5% total alleles by standard HRM. LCN-HRM allowed these mutations to be identified by direct sequencing of those positive reactions.LCN-HRM was then used to review formalin-fixed paraffin-embedded (FFPE) clinical samples showing discordant findings between sequencing and HRM for KRAS exon 2 and EGFR exons 19 and 21. Both true mutations present at low levels and sequence changes due to artefacts were detected by LCN-HRM. The use of high fidelity polymerases showed that the majority of the artefacts were derived from the damaged template rather than replication errors during amplification. LCN-HRM bridges the sensitivity gap between HRM and sequencing and is effective in distinguishing between artefacts and true mutations.

  20. Quantifying environmental limiting factors on tree cover using geospatial data.

    Science.gov (United States)

    Greenberg, Jonathan A; Santos, Maria J; Dobrowski, Solomon Z; Vanderbilt, Vern C; Ustin, Susan L

    2015-01-01

    Environmental limiting factors (ELFs) are the thresholds that determine the maximum or minimum biological response for a given suite of environmental conditions. We asked the following questions: 1) Can we detect ELFs on percent tree cover across the eastern slopes of the Lake Tahoe Basin, NV? 2) How are the ELFs distributed spatially? 3) To what extent are unmeasured environmental factors limiting tree cover? ELFs are difficult to quantify as they require significant sample sizes. We addressed this by using geospatial data over a relatively large spatial extent, where the wall-to-wall sampling ensures the inclusion of rare data points which define the minimum or maximum response to environmental factors. We tested mean temperature, minimum temperature, potential evapotranspiration (PET) and PET minus precipitation (PET-P) as potential limiting factors on percent tree cover. We found that the study area showed system-wide limitations on tree cover, and each of the factors showed evidence of being limiting on tree cover. However, only 1.2% of the total area appeared to be limited by the four (4) environmental factors, suggesting other unmeasured factors are limiting much of the tree cover in the study area. Where sites were near their theoretical maximum, non-forest sites (tree cover demand, and closed-canopy forests were not limited by any particular environmental factor. The detection of ELFs is necessary in order to fully understand the width of limitations that species experience within their geographic range.

  1. Scope and limitations of the TEMPO/EPR method for singlet oxygen detection: the misleading role of electron transfer.

    Science.gov (United States)

    Nardi, Giacomo; Manet, Ilse; Monti, Sandra; Miranda, Miguel A; Lhiaubet-Vallet, Virginie

    2014-12-01

    For many biological and biomedical studies, it is essential to detect the production of (1)O2 and quantify its production yield. Among the available methods, detection of the characteristic 1270-nm phosphorescence of singlet oxygen by time-resolved near-infrared (TRNIR) emission constitutes the most direct and unambiguous approach. An alternative indirect method is electron paramagnetic resonance (EPR) in combination with a singlet oxygen probe. This is based on the detection of the TEMPO free radical formed after oxidation of TEMP (2,2,6,6-tetramethylpiperidine) by singlet oxygen. Although the TEMPO/EPR method has been widely employed, it can produce misleading data. This is demonstrated by the present study, in which the quantum yields of singlet oxygen formation obtained by TRNIR emission and by the TEMPO/EPR method are compared for a set of well-known photosensitizers. The results reveal that the TEMPO/EPR method leads to significant overestimation of singlet oxygen yield when the singlet or triplet excited state of the photosensitizer is efficiently quenched by TEMP, acting as electron donor. In such case, generation of the TEMP(+) radical cation, followed by deprotonation and reaction with molecular oxygen, gives rise to an EPR-detectable TEMPO signal that is not associated with singlet oxygen production. This knowledge is essential for an appropriate and error-free application of the TEMPO/EPR method in chemical, biological, and medical studies. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Detecting Position Using ARKit II: Generating Position-Time Graphs in Realtime and Further Information on Limitations of ARKit

    Science.gov (United States)

    Dilek, Ufuk; Erol, Mustafa

    2018-01-01

    ARKit is a framework which allows developers to create augmented reality apps for the iPhone and iPad. In a previous study, we had shown that it could be used to detect position in educational physics experiments and emphasized that the ability to provide position data in real-time was one of the prominent features of this newly emerging…

  3. Natural history of optical coherence tomography-detected non-flow-limiting edge dissections following drug-eluting stent implantation

    DEFF Research Database (Denmark)

    Radu, Maria D; Räber, Lorenz; Heo, Jungho

    2014-01-01

    history and clinical implications remain unclear. The objectives of the present study were to assess the morphology, healing response, and clinical outcomes of OCT-detected edge dissections using serial OCT imaging at baseline and at one year following drug-eluting stent (DES) implantation. METHODS...

  4. Effects of Kapton Sample Cell Windows on the Detection Limit of Smectite: Implications for CheMin on the Mars Science Laboratory Mission

    Science.gov (United States)

    Achilles, C. N.; Ming, Douglas W.; Morris, R. V.; Blake, D. F.

    2012-01-01

    The CheMin instrument on the Mars Science Laboratory (MSL) rover Curiosity is an X-ray diffraction (XRD) and X-ray fluorescence (XRF) instrument capable of providing the mineralogical and chemical compositions of rocks and soils on the surface of Mars. CheMin uses a microfocus X-ray tube with a Co target, transmission geometry, and an energy-discriminating X-ray sensitive CCD to produce simultaneous 2-D XRD patterns and energy-dispersive X-ray histograms from powdered samples. CheMin has two different window materials used for sample cells -- Mylar and Kapton. Instrument details are provided elsewhere. Fe/Mg-smectite (e.g., nontronite) has been identified in Gale Crater, the MSL future landing site, by CRISM spectra. While large quantities of phyllosilicate minerals will be easily detected by CheMin, it is important to establish detection limits of such phases to understand capabilities and limitations of the instrument. A previous study indicated that the (001) peak of smectite at 15 Ang was detectable in a mixture of 1 wt.% smectite with olivine when Mylar is the window material for the sample cell. Complications arise when Kapton is the window material because Kapton itself also has a diffraction peak near 15 Ang (6.8 deg 2 Theta). This study presents results of mineral mixtures of smectite and olivine to determine smectite detection limits for Kapton sample cells. Because the intensity and position of the smectite (001) peak depends on the hydration state, we also analyzed mixtures with "hydrated" and "dehydrated"h smectite to examine the effects of hydration state on detection limits.

  5. Enhancement of laser-induced breakdown spectroscopy (LIBS) Detection limit using a low-pressure and short-pulse laser-induced plasma process.

    Science.gov (United States)

    Wang, Zhen Zhen; Deguchi, Yoshihiro; Kuwahara, Masakazu; Yan, Jun Jie; Liu, Ji Ping

    2013-11-01

    Laser-induced breakdown spectroscopy (LIBS) technology is an appealing technique compared with many other types of elemental analysis because of the fast response, high sensitivity, real-time, and noncontact features. One of the challenging targets of LIBS is the enhancement of the detection limit. In this study, the detection limit of gas-phase LIBS analysis has been improved by controlling the pressure and laser pulse width. In order to verify this method, low-pressure gas plasma was induced using nanosecond and picosecond lasers. The method was applied to the detection of Hg. The emission intensity ratio of the Hg atom to NO (IHg/INO) was analyzed to evaluate the LIBS detection limit because the NO emission (interference signal) was formed during the plasma generation and cooling process of N2 and O2 in the air. It was demonstrated that the enhancement of IHg/INO arose by decreasing the pressure to a few kilopascals, and the IHg/INO of the picosecond breakdown was always much higher than that of the nanosecond breakdown at low buffer gas pressure. Enhancement of IHg/INO increased more than 10 times at 700 Pa using picosecond laser with 35 ps pulse width. The detection limit was enhanced to 0.03 ppm (parts per million). We also saw that the spectra from the center and edge parts of plasma showed different features. Comparing the central spectra with the edge spectra, IHg/INO of the edge spectra was higher than that of the central spectra using the picosecond laser breakdown process.

  6. X-ray Bursts in Neutron Star and Black Hole Binaries from USA Data: Detections and Upper Limits

    Energy Technology Data Exchange (ETDEWEB)

    Tournear, Derek M

    2003-02-18

    Narayan and Heyl (2002) have developed a theoretical framework to convert suitable upper limits on type I X-ray bursts from accreting black hole candidates (BHCs) into evidence for an event horizon. However, no appropriate observational limit exists in the literature. In this paper we survey 2101.2 ks of data from the Unconventional Stellar Aspect (USA) X-ray timing experiment and 5142 ks of data from the Rossi X-ray Timing Explorer (RXTE) experiment to obtain a formal constraint of this type. 1122 ks of neutron star data yield a population averaged mean burst rate of 1.69 x 10{sup -5} bursts s{sup -1} while 6081 ks of BHC data yield a 95% confidence level upper limit of 4.9 x 10{sup -7} bursts s{sup -1}. This is the first published limit of this type for Black Hole Candidates. Applying the theoretical framework of Narayan and Heyl (2002) we calculate regions of unstable luminosity where the neutron stars are expected to burst and the BHCs would be expected to burst if they had a surface. In this unstable luminosity region 464 ks of neutron star data yield an averaged mean burst rate of 4.1 x 10{sup -5} bursts s{sup -1} and 1512 ks of BHC data yield a 95% confidence level upper limit of 2.0 x 10{sup 6} bursts s{sup -1}, and a limit of > 10 {sigma} that BHCs do not burst with a rate similar to the rate of neutron stars in these unstable regions. This gives further evidence that BHCs do not have surfaces unless there is some new physics occurring on their surface.

  7. Utility and limitations of Addenbrooke's Cognitive Examination-Revised for detecting mild cognitive impairment in Parkinson's disease.

    Science.gov (United States)

    Komadina, Natalie C; Terpening, Zoe; Huang, Yue; Halliday, Glenda M; Naismith, Sharon L; Lewis, Simon J G

    2011-01-01

    To evaluate the utility of the Addenbrooke's Cognitive Examination-Revised (ACE-R) as a screening tool for mild cognitive impairment in Parkinson's disease (PD-MCI). PD patients underwent comprehensive neuropsychological and neurological evaluations and ACE-R assessment. The ACE-R was superior to the Mini-Mental State Exam (MMSE) in detecting PD-MCI, with a cutoff score of ≤93 offering a sensitivity of 61% and a specificity of 64%. The utility of the ACE-R in detecting PD-MCI is largely influenced by the fluency sub-domain score, and has optimal discriminability when utilized in patients with lower levels of education (≤12 years of formal schooling). The ACE-R must be used cautiously as a screening tool for PD-MCI, with results being most influenced by its fluency sub-domain score and patient education levels. Copyright © 2011 S. Karger AG, Basel.

  8. Minimum Q Electrically Small Antennas

    DEFF Research Database (Denmark)

    Kim, O. S.

    2012-01-01

    Theoretically, the minimum radiation quality factor Q of an isolated resonance can be achieved in a spherical electrically small antenna by combining TM1m and TE1m spherical modes, provided that the stored energy in the antenna spherical volume is totally suppressed. Using closed-form expressions...... for a multiarm spherical helix antenna confirm the theoretical predictions. For example, a 4-arm spherical helix antenna with a magnetic-coated perfectly electrically conducting core (ka=0.254) exhibits the Q of 0.66 times the Chu lower bound, or 1.25 times the minimum Q....

  9. Detection limits of nuclear radiation and radioactivity measurements. Digital, non-selective measurements on untreated specimens. Draft. Nachweisgrenzen bei Kernstrahlungs- und Radioaktivitaetsmessungen. Digitale, nichtselektive Messungen ohne Probenbehandlung. Entwurf

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    The standard applies to nuclear radiation measurements where the number of pulses is recorded directly, considering exclusively the statistical character of radioactive decay and pulse counting, with the measuring time being short with regard to the half-life of radionuclides, and instrument dead-times being neglectible. The standard is intended to define suitable characteristics allowing an evaluation of detection efficiency. Two criteria are explained for given error probabilities: the sensitivity limit which allows a decision to be made as to whether the pulses recorded include values contributed by the sample; the detection limit which permits an evaluation of the measuring method in terms of suitability to the measuring goals. (orig./HP).

  10. Comparison of sensitivities and detection limits between direct excitation and secondary excitation modes in energy dispersive x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Artz, B.E.; Short, M.A.

    1976-01-01

    A comparison was made between the direct tube excitation mode and the secondary target excitation mode using a Kevex 0810 energy dispersive x-ray fluorescence system. Relative sensitivities and detection limits were determined with two system configurations. The first configuration used a standard, high power, x-ray fluorescence tube to directly excite the specimen. Several x-ray tubes, including chromium, molybdenum, and tungsten, both filtered and not filtered, were employed. The second configuration consisted of using the x-ray tube to excite a secondary target which in turn excited the specimen. Appropriate targets were compared to the direct excitation results. Relative sensitivities and detection limits were determined for K-series lines for elements from magnesium to barium contained in a low atomic number matrix and in a high atomic number matrix

  11. Characteristics of right-sided colonic neoplasia and colonoscopy barriers limiting their early detection and prognosis: a review of the literature.

    Science.gov (United States)

    Fischbach, Wolfgang; Elsome, Rory; Amlani, Bharat

    2018-06-05

    Colonoscopy provides less protection from colorectal cancer in the right colon than the left. Areas covered: This review examines patient outcomes and colonoscopy success rates to identify factors that limit the protective effect of colonoscopy in the right colon. The MEDLINE and Embase databases were searched for literature from 2000 onwards, on the long-term outcomes and differences in screening practice between the right and left colon. In total, 12 systematic reviews (including nine meta-analyses) and 44 primary data records were included. Differences in patient outcomes and colonoscopy practice were identified between the right and left colon, suggesting that several factors, many of which disproportionally affect the right colon, impact lesion detection rates. Shorter withdrawal times reduce detection rates, while longer times significantly increase detection; mostly of adenomas in the right colon. Colonoscope attachments often only show a significant improvement in detection rates in the right colon, suggesting detection is more challenging due to visibility of the right colonic mucosa. Higher bowel cleansing grades significantly improve detection rates in the right colon compared to the left. Expert commentary: These findings confirm the need for continued improvement of colonoscopy effectiveness, and obligatory quality assessment, overall and especially in the right colon.

  12. Improvement of detection limits in the annular 241Am radioisotope-excited X-ray fluorescence analysis for minor elements of environmental sample

    International Nuclear Information System (INIS)

    Thai My Phe; Ngo Quang Huy; Nguyen Van Suc; Tran Van Luyen; Nguyen Van Mai; Dao Van Hoang; Trinh Thi Bich

    2003-01-01

    The improvement of limit detection to elements Pb, Sr, Zr, Nd, and Ba in mud samples is presented. Two ways for reducing background radiation are: 1/ choosing the optimum γ-ray-excited X-ray assembly such as scattering angle (θ), filter for primary beam, excited holder, collimator for fluorescent lines, etc; 2/ using the chemical separation method to remove major composition for matrix reduction. (NHA)

  13. Testing the discrimination and detection limits of WorldView-2 imagery on a challenging invasive plant target

    Science.gov (United States)

    Robinson, T. P.; Wardell-Johnson, G. W.; Pracilio, G.; Brown, C.; Corner, R.; van Klinken, R. D.

    2016-02-01

    Invasive plants pose significant threats to biodiversity and ecosystem function globally, leading to costly monitoring and management effort. While remote sensing promises cost-effective, robust and repeatable monitoring tools to support intervention, it has been largely restricted to airborne platforms that have higher spatial and spectral resolutions, but which lack the coverage and versatility of satellite-based platforms. This study tests the ability of the WorldView-2 (WV2) eight-band satellite sensor for detecting the invasive shrub mesquite (Prosopis spp.) in the north-west Pilbara region of Australia. Detectability was challenged by the target taxa being largely defoliated by a leaf-tying biological control agent (Gelechiidae: Evippe sp. #1) and the presence of other shrubs and trees. Variable importance in the projection (VIP) scores identified bands offering greatest capacity for discrimination were those covering the near-infrared, red, and red-edge wavelengths. Wavelengths between 400 nm and 630 nm (coastal blue, blue, green, yellow) were not useful for species level discrimination in this case. Classification accuracy was tested on three band sets (simulated standard multispectral, all bands, and bands with VIP scores ≥1). Overall accuracies were comparable amongst all band-sets (Kappa = 0.71-0.77). However, mesquite omission rates were unacceptably high (21.3%) when using all eight bands relative to the simulated standard multispectral band-set (9.5%) and the band-set informed by VIP scores (11.9%). An incremental cover evaluation on the latter identified most omissions to be for objects high mapping accuracy of objects >16 m2 allows application for mapping mesquite shrubs and coalesced stands, the former not previously possible, even with 3 m resolution hyperspectral imagery. WV2 imagery offers excellent portability potential for detecting other species where spectral/spatial resolution or coverage has been an impediment. New generation satellite

  14. Applying ISO 11929:2010 Standard to detection limit calculation in least-squares based multi-nuclide gamma-ray spectrum evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kanisch, G., E-mail: guenter.kanisch@hanse.net

    2017-05-21

    The concepts of ISO 11929 (2010) are applied to evaluation of radionuclide activities from more complex multi-nuclide gamma-ray spectra. From net peak areas estimated by peak fitting, activities and their standard uncertainties are calculated by weighted linear least-squares method with an additional step, where uncertainties of the design matrix elements are taken into account. A numerical treatment of the standard's uncertainty function, based on ISO 11929 Annex C.5, leads to a procedure for deriving decision threshold and detection limit values. The methods shown allow resolving interferences between radionuclide activities also in case of calculating detection limits where they can improve the latter by including more than one gamma line per radionuclide. The co'mmon single nuclide weighted mean is extended to an interference-corrected (generalized) weighted mean, which, combined with the least-squares method, allows faster detection limit calculations. In addition, a new grouped uncertainty budget was inferred, which for each radionuclide gives uncertainty budgets from seven main variables, such as net count rates, peak efficiencies, gamma emission intensities and others; grouping refers to summation over lists of peaks per radionuclide.

  15. Long range surface plasmon resonance with ultra-high penetration depth for self-referenced sensing and ultra-low detection limit using diverging beam approach

    Energy Technology Data Exchange (ETDEWEB)

    Isaacs, Sivan, E-mail: sivan.isaacs@gmail.com; Abdulhalim, Ibrahim [Department of Electro-Optical Engineering and TheIlse Katz Institute for Nanoscale Science and Technology, Ben Gurion University of the Negev, Beer Sheva 84105 (Israel); NEW CREATE Programme, School of Materials Science and Engineering, 1 CREATE Way, Research Wing, #02-06/08, Singapore 138602 (Singapore)

    2015-05-11

    Using an insulator-metal-insulator structure with dielectric having refractive index (RI) larger than the analyte, long range surface plasmon (SP) resonance exhibiting ultra-high penetration depth is demonstrated for sensing applications of large bioentities at wavelengths in the visible range. Based on the diverging beam approach in Kretschmann-Raether configuration, one of the SP resonances is shown to shift in response to changes in the analyte RI while the other is fixed; thus, it can be used as a built in reference. The combination of the high sensitivity, high penetration depth and self-reference using the diverging beam approach in which a dark line is detected of the high sensitivity, high penetration depth, self-reference, and the diverging beam approach in which a dark line is detected using large number of camera pixels with a smart algorithm for sub-pixel resolution, a sensor with ultra-low detection limit is demonstrated suitable for large bioentities.

  16. Surface modification of alignment layer by ultraviolet irradiation to dramatically improve the detection limit of liquid-crystal-based immunoassay for the cancer biomarker CA125.

    Science.gov (United States)

    Su, Hui-Wen; Lee, Mon-Juan; Lee, Wei

    2015-05-01

    Liquid crystal (LC)-based biosensing has attracted much attention in recent years. We focus on improving the detection limit of LC-based immunoassay techniques by surface modification of the surfactant alignment layer consisting of dimethyloctadecyl[3-(trimethoxysilyl)propyl]ammonium chloride (DMOAP). The cancer biomarker CA125 was detected with an array of anti-CA125 antibodies immobilized on the ultraviolet (UV)-modified DMOAP monolayer. Compared with a pristine counterpart, UV irradiation enhanced the binding affinity of the CA125 antibody and reproducibility of immunodetection in which a detection limit of 0.01 ng∕ml for the cancer biomarker CA125 was achieved. Additionally, the optical texture observed under a crossed polarized microscope was correlated with the analyte concentration. In a proof-of-concept experiment using CA125-spiked human serum as the analyte, specific binding between the CA125 antigen and the anti-CA125 antibody resulted in a distinct and concentration-dependent optical response despite the high background caused by nonspecific binding of other biomolecules in the human serum. Results from this study indicate that UVmodification of the alignment layer, as well as detection with LCs of large birefringence, contributes to the enhanced performance of the label-free LC-based immunodetection, which may be considered a promising alternative to conventional label-based methods.

  17. Fermat and the Minimum Principle

    Indian Academy of Sciences (India)

    Arguably, least action and minimum principles were offered or applied much earlier. This (or these) principle(s) is/are among the fundamental, basic, unifying or organizing ones used to describe a variety of natural phenomena. It considers the amount of energy expended in performing a given action to be the least required ...

  18. Coupling between minimum scattering antennas

    DEFF Research Database (Denmark)

    Andersen, J.; Lessow, H; Schjær-Jacobsen, Hans

    1974-01-01

    Coupling between minimum scattering antennas (MSA's) is investigated by the coupling theory developed by Wasylkiwskyj and Kahn. Only rotationally symmetric power patterns are considered, and graphs of relative mutual impedance are presented as a function of distance and pattern parameters. Crossed...

  19. Detection of Acute and Early HIV-1 Infections in an HIV Hyper-Endemic Area with Limited Resources.

    Directory of Open Access Journals (Sweden)

    Simnikiwe H Mayaphi

    Full Text Available Two thirds of the world's new HIV infections are in sub-Saharan Africa. Acute HIV infection (AHI is the time of virus acquisition until the appearance of HIV antibodies. Early HIV infection, which includes AHI, is the interval between virus acquisition and establishment of viral load set-point. This study aimed to detect acute and early HIV infections in a hyper-endemic setting.This was a cross-sectional diagnostic study that enrolled individuals who had negative rapid HIV results in five clinics in South Africa. Pooled nucleic acid amplification testing (NAAT was performed, followed by individual sample testing in positive pools. NAAT-positive participants were recalled to the clinics for confirmatory testing and appropriate management. HIV antibody, p24 antigen, Western Blot and avidity tests were performed for characterization of NAAT-positive samples.The study enrolled 6910 individuals with negative rapid HIV results. Median age was 27 years (interquartile range {IQR}: 23-31. NAAT was positive in 55 samples, resulting in 0.8% newly diagnosed HIV-infected individuals (95% confidence interval {CI}: 0.6-1.0. The negative predictive value for rapid HIV testing was 99.2% (95% CI: 99.0-99.4. Characterization of NAAT-positive samples revealed that 0.04% (95% CI: 0.000-0.001 had AHI, 0.3% (95% CI: 0.1-0.4 had early HIV infection, and 0.5% (95% CI: 0.5-0.7 had chronic HIV infection. Forty-seven (86% of NAAT-positive participants returned for follow-up at a median of 4 weeks (IQR: 2-8. Follow-up rapid tests were positive in 96% of these participants.NAAT demonstrated that a substantial number of HIV-infected individuals are misdiagnosed at South African points-of-care. Follow-up rapid tests done within a 4 week interval detected early and chronic HIV infections initially missed by rapid HIV testing. This may be a practical and affordable strategy for earlier detection of these infections in resource-constrained settings. Newer molecular tests that can

  20. Limitations in SELDI-TOF MS whole serum proteomic profiling with IMAC surface to specifically detect colorectal cancer

    International Nuclear Information System (INIS)

    Wang, Qi; Gu, Jin; Shen, Jing; Li, Zhen-fu; Jie, Jian-zheng; Wang, Wen-yue; Wang, Jin; Zhang, Zhong-tao; Li, Zhi-xia; Yan, Li

    2009-01-01

    Surface enhanced laser desorption and ionization time-of-flight mass spectrometry (SELDI-TOF-MS) analysis on serum samples was reported to be able to detect colorectal cancer (CRC) from normal or control patients. We carried out a validation study of a SELDI-TOF MS approach with IMAC surface sample processing to identify CRC. A retrospective cohort of 338 serum samples including 154 CRCs, 67 control cancers and 117 non-cancerous conditions was profiled using SELDI-TOF-MS. No CRC 'specific' classifier was found. However, a classifier consisting of two protein peaks separates cancer from non-cancerous conditions with high accuracy. In this study, the SELDI-TOF-MS-based protein expression profiling approach did not perform to identify CRC. However, this technique is promising in distinguishing patients with cancer from a non-cancerous population; it may be useful for monitoring recurrence of CRC after treatment

  1. Using European travellers as an early alert to detect emerging pathogens in countries with limited laboratory resources

    Directory of Open Access Journals (Sweden)

    Grais Rebecca

    2007-01-01

    Full Text Available Abstract Background The volume, extent and speed of travel have dramatically increased in the past decades, providing the potential for an infectious disease to spread through the transportation network. By collecting information on the suspected place of infection, existing surveillance systems in industrialized countries may provide timely information for areas of the world without adequate surveillance currently in place. We present the results of a case study using reported cases of Shigella dysenteriae serotype 1 (Sd1 in European travellers to detect "events" of Sd1, related to either epidemic cases or endemic cases in developing countries. Methods We identified papers from a Medline search for reported events of Sd1 from 1940 to 2002. We requested data on shigella infections reported to the responsible surveillance entities in 17 European countries. Reports of Sd1 from the published literature were then compared with Sd1 notified cases among European travellers from 1990 to 2002. Results Prior to a large epidemic in 1999–2000, no cases of Sd1 had been identified in West Africa. However, if travellers had been used as an early warning, Sd1 could have been identified in this region as earlier as 1992. Conclusion This project demonstrates that tracking diseases in European travellers could be used to detect emerging disease in developing countries. This approach should be further tested with a view to the continuous improvement of national health surveillance systems and existing European networks, and may play a significant role in aiding the international public health community to improve infectious disease control.

  2. The limitations on organic detection in Mars-like soils by thermal volatilization-gas chromatography-MS and their implications for the Viking results.

    Science.gov (United States)

    Navarro-González, Rafael; Navarro, Karina F; de la Rosa, José; Iñiguez, Enrique; Molina, Paola; Miranda, Luis D; Morales, Pedro; Cienfuegos, Edith; Coll, Patrice; Raulin, François; Amils, Ricardo; McKay, Christopher P

    2006-10-31

    The failure of Viking Lander thermal volatilization (TV) (without or with thermal degradation)-gas chromatography (GC)-MS experiments to detect organics suggests chemical rather than biological interpretations for the reactivity of the martian soil. Here, we report that TV-GC-MS may be blind to low levels of organics on Mars. A comparison between TV-GC-MS and total organics has been conducted for a variety of Mars analog soils. In the Antarctic Dry Valleys and the Atacama and Libyan Deserts we find 10-90 mug of refractory or graphitic carbon per gram of soil, which would have been undetectable by the Viking TV-GC-MS. In iron-containing soils (jarosites from Rio Tinto and Panoche Valley) and the Mars simulant (palogonite), oxidation of the organic material to carbon dioxide (CO(2)) by iron oxides and/or their salts drastically attenuates the detection of organics. The release of 50-700 ppm of CO(2) by TV-GC-MS in the Viking analysis may indicate that an oxidation of organic material took place. Therefore, the martian surface could have several orders of magnitude more organics than the stated Viking detection limit. Because of the simplicity of sample handling, TV-GC-MS is still considered the standard method for organic detection on future Mars missions. We suggest that the design of future organic instruments for Mars should include other methods to be able to detect extinct and/or extant life.

  3. The limitations on organic detection in Mars-like soils by thermal volatilization–gas chromatography–MS and their implications for the Viking results

    Science.gov (United States)

    Navarro-González, Rafael; Navarro, Karina F.; de la Rosa, José; Iñiguez, Enrique; Molina, Paola; Miranda, Luis D.; Morales, Pedro; Cienfuegos, Edith; Coll, Patrice; Raulin, François; Amils, Ricardo; McKay, Christopher P.

    2006-01-01

    The failure of Viking Lander thermal volatilization (TV) (without or with thermal degradation)–gas chromatography (GC)–MS experiments to detect organics suggests chemical rather than biological interpretations for the reactivity of the martian soil. Here, we report that TV–GC–MS may be blind to low levels of organics on Mars. A comparison between TV–GC–MS and total organics has been conducted for a variety of Mars analog soils. In the Antarctic Dry Valleys and the Atacama and Libyan Deserts we find 10–90 μg of refractory or graphitic carbon per gram of soil, which would have been undetectable by the Viking TV–GC–MS. In iron-containing soils (jarosites from Rio Tinto and Panoche Valley) and the Mars simulant (palogonite), oxidation of the organic material to carbon dioxide (CO2) by iron oxides and/or their salts drastically attenuates the detection of organics. The release of 50–700 ppm of CO2 by TV–GC–MS in the Viking analysis may indicate that an oxidation of organic material took place. Therefore, the martian surface could have several orders of magnitude more organics than the stated Viking detection limit. Because of the simplicity of sample handling, TV–GC–MS is still considered the standard method for organic detection on future Mars missions. We suggest that the design of future organic instruments for Mars should include other methods to be able to detect extinct and/or extant life. PMID:17060639

  4. In situ quantification of ultra-low O2 concentrations in oxygen minimum zones

    DEFF Research Database (Denmark)

    Larsen, Morten; Lehner, Philipp; Borisov, Sergey M.

    2016-01-01

    based on the palladium(II)-benzoporphyrin luminophore, immobilized in a perfluorinated matrix with high O2 permeability. The trace sensor has a detection limit of ∼5 nmol L−1 with a dynamic range extending up to ∼2 μmol L−1. The sensor demonstrates a response time ..., and fully reversible response to hydrostatic pressure and temperature. The sensor showed excellent stability for continuously measurements during depth profiling in Oxygen Minimum Zones (OMZ). The novel sensor was deployed in situ using a Trace Oxygen Profiler instrument (TOP) equipped with two additional O...

  5. A discussion on the merits and limitations of using drive-by monitoring to detect localised damage in a bridge

    Science.gov (United States)

    Hester, David; González, Arturo

    2017-06-01

    Given the large number of bridges that currently have no instrumentation, there are obvious advantages in monitoring the condition of a bridge by analysing the response of a vehicle crossing it. As a result, the last two decades have seen a rise in the research attempting to solve the problem of identifying damage in a bridge from vehicle measurements. This paper examines the theoretical feasibility and practical limitations of a drive-by system in identifying damage associated to localised stiffness losses. First, the nature of the damage feature that is sought within the vehicle response needs to be characterized. For this purpose, the total vehicle response is considered to be made of 'static' and 'dynamic' components, and where the bridge has experienced a localised loss in stiffness, an additional 'damage' component. Understanding the nature of this 'damage' component is crucial to have an informed discussion on how damage can be identified and localised. Leveraging this new understanding, the authors propose a wavelet-based drive-by algorithm. By comparing the effect of the 'damage' component to other key effects defining the measurements such as 'vehicle speed', the 'road profile' and 'noise' on a wavelet contour plot, it is possible to establish if there is a frequency range where drive-by can be successful. The algorithm uses then specific frequency bands to improve the sensitivity to damage with respect to limitations imposed by Vehicle-Bridge vibrations. Recommendations on the selection of the mother wavelet and frequency band are provided. Finally, the paper discusses the impact of noise and road profile on the ability of the approach to identify damage and how periodic measurements can be effective at monitoring localised stiffness changes.

  6. Variation in the limit-of-detection of the ProSpecT Campylobacter microplate enzyme immunoassay in stools spiked with emerging Campylobacter species.

    Science.gov (United States)

    Bojanić, Krunoslav; Midwinter, Anne Camilla; Marshall, Jonathan Craig; Rogers, Lynn Elizabeth; Biggs, Patrick Jon; Acke, Els

    2016-08-01

    Campylobacter enteritis in humans is primarily associated with C. jejuni/coli infection. The impact of other Campylobacter spp. is likely to be underestimated due to the bias of culture methods towards Campylobacter jejuni/coli diagnosis. Stool antigen tests are becoming increasingly popular and appear generally less species-specific. A review of independent studies of the ProSpecT® Campylobacter Microplate enzyme immunoassay (EIA) developed for C. jejuni/coli showed comparable diagnostic results to culture methods but the examination of non-jejuni/coli Campylobacter spp. was limited and the limit-of-detection (LOD), where reported, varied between studies. This study investigated LOD of EIA for Campylobacter upsaliensis, Campylobacter hyointestinalis and Campylobacter helveticus spiked in human stools. Multiple stools and Campylobacter isolates were used in three different concentrations (10(4)-10(9)CFU/ml) to reflect sample heterogeneity. All Campylobacter species evaluated were detectable by EIA. Multivariate analysis showed LOD varied between Campylobacter spp. and faecal consistency as fixed effects and individual faecal samples as random effects. EIA showed excellent performance in replicate testing for both within and between batches of reagents, in agreement between visual and spectrophotometric reading of results, and returned no discordance between the bacterial concentrations within independent dilution test runs (positive results with lower but not higher concentrations). This study shows how limitations in experimental procedures lead to an overestimation of consistency and uniformity of LOD for EIA that may not hold under routine use in diagnostic laboratories. Benefits and limitations for clinical practice and the influence on estimates of performance characteristics from detection of multiple Campylobacter spp. by EIA are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Limitations of Using IL-17A and IFN-γ-Induced Protein 10 to Detect Bovine Tuberculosis

    Science.gov (United States)

    Xin, Ting; Gao, Xintao; Yang, Hongjun; Li, Pingjun; Liang, Qianqian; Hou, Shaohua; Sui, Xiukun; Guo, Xiaoyu; Yuan, Weifeng; Zhu, Hongfei; Ding, Jiabo; Jia, Hong

    2018-01-01

    Bovine tuberculosis (bTB) is primarily caused by infection with Mycobacterium bovis, which belongs to the Mycobacterium tuberculosis complex. The airborne route is considered the most common for transmission of M. bovis, and more than 15% of cattle with bTB shed the Mycobacterium, which can be detect by nested PCR to amplify mycobacterial mpb70 from a nasal swab from a cow. To screen for cytokines fostering early and accurate detection of bTB, peripheral blood mononuclear cells were isolated from naturally M. bovis-infected, experimentally M. bovis 68002-infected, and uninfected cattle, then these cells were stimulated by PPD-B, CFP-10-ESAT-6 (CE), or phosphate-buffered saline (PBS) for 6 h. The levels of interferon gamma (IFN-γ), IFN-γ-induced protein 10 (IP-10), IL-6, IL-12, IL-17A, and tumor necrosis factor alpha mRNA were measured using real-time PCR. To explore the cytokines associated with different periods of M. bovis infection, cattle were divided into three groups: PCR-positive, PCR-negative, and uninfected using the tuberculin skin test, CFP-10/ESAT-6/TB10.4 protein cocktail-based skin test, IFN-γ release assay (IGRA), CFP-10/ESAT-6 (CE)-based IGRA, and nested PCR. The expression of IP-10, IL-17A, and IFN-γ proteins induced by PPD-B, CE, or PBS was detected by ELISA. The results showed that levels of PPD-B-stimulated IL-17A and IP-10 (mRNA and protein), and CE-induced IP-10 (mRNA and protein) were significantly higher in cattle naturally or experimentally infected with M. bovis than in those that were uninfected. The levels of PPD-B- or CE-induced IL-17A and IP-10 (protein) could be used to differentiate M. bovis-infected calves from uninfected ones for 6 to 30 weeks post-infection, whereas PPD-B- and CE-induced IP-10 and IL-17A mRNA expression could be used to differentiate M. bovis-infected calves from uninfected ones between 6 and 58 weeks post-infection. However, CE-induced IL-17A (protein) was not a reliable indicator of M. bovis infection

  8. Evaluation of a manual DNA extraction protocol and an isothermal amplification assay for detecting HIV-1 DNA from dried blood spots for use in resource-limited settings.

    Science.gov (United States)

    Jordan, Jeanne A; Ibe, Christine O; Moore, Miranda S; Host, Christel; Simon, Gary L

    2012-05-01

    In resource-limited settings (RLS) dried blood spots (DBS) are collected on infants and transported through provincial laboratories to a central facility where HIV-1 DNA PCR testing is performed using specialized equipment. Implementing a simpler approach not requiring such equipment or skilled personnel could allow the more numerous provincial laboratories to offer testing, improving turn-around-time to identify and treat infected infants sooner. Assess performances of a manual DNA extraction method and helicase-dependent amplification (HDA) assay for detecting HIV-1 DNA from DBS. 60 HIV-1 infected adults were enrolled, blood samples taken and DBS made. DBS extracts were assessed for DNA concentration and beta globin amplification using PCR and melt-curve analysis. These same extracts were then tested for HIV-1 DNA using HDA and compared to results generated by PCR and pyrosequencing. Finally, HDA limit of detection (LOD) studies were performed using DBS extracts prepared with known numbers of 8E5 cells. The manual extraction protocol consistently yielded high concentrations of amplifiable DNA from DBS. LOD assessment demonstrated HDA detected ∼470 copies/ml of HIV-1 DNA extracts in 4/4 replicates. No statistical difference was found using the McNemar's test when comparing HDA to PCR for detecting HIV-1 DNA from DBS. Using just a magnet, heat block and pipettes, the manual extraction protocol and HDA assay detected HIV-1 DNA from DBS at levels that would be useful for early infant diagnosis. Next steps will include assessing HDA for non-B HIV-1 subtypes recognition and comparison to Roche HIV-1 DNA v1.5 PCR assay. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Use and limitations of radiolabelled anti-CEA antibodies and their fragments for photoscanning detection of human colorectal carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Mach, J P; Forni, M; Ritschard, J; Buchegger, F; Carrel, S; Widgren, S; Donath, A; Alberto, P [Lausanne Univ. (Switzerland)

    1980-08-01

    Fifty-three patients with histologically proven carcinoma were injected with highly purified (/sup 131/I)-labelled goat antibodies or fragments of antibodies against carcinoembryonic antigen (CEA). Each patient was tested by external photoscanning 4, 24, 36, 48h after injection. In 22 patients (16 of 38 injected with intact antibodies, 5 of 13 with F(ab')/sub 2/ fragments and 1 of 2 with Fab' fragments), an increased concentration of /sup 131/I radioactivity corresponding to the previously known tumor location was detected by photoscanning 36-48 h after injection. Blood pool and secreted radioactivity was determined in all patients by injecting 15 min after scanning, (sup(99m)Tc)-labeled normal serum albumin and free sup(99m)TcO/sub 4//sup -/. The computerized subtraction of sup(99m)Tc from /sup 131/I radioactivity enhanced the definition of tumor localization in the 22 positive patients. However, in spite of the computerized subtraction, interpretation of the scans remained doubtful for 12 patients and was entirely negative for 19 additional patients.

  10. Limit of detection of a fiber optics gyroscope using a super luminescent radiation source; Limite de deteccion de un giroscopio de fibra optica usando una fuente de radiacion superluminiscente

    Energy Technology Data Exchange (ETDEWEB)

    Sandoval R, G.E. [Laboratorio de Optica Aplicada, Centro de Ciencias Aplicadas y Desarrollo Tecnologico, Universidad Nacional Autonoma de Mexico, Apartado Postal 70-186, 04510 Mexico D.F. (Mexico); Nikolaev, V.A. [Departamento de Optica y Radiofisica Cuantica, Universidad Estatal de Telecomunicaciones de San Petersburgo, M.A. Bonch-Bruyevich, Kanal Moika 61, Saint Petersburg 191186, (Russian Federation)

    2003-07-01

    The main objective of this work is to establish the dependence of characteristics of the fiber optics gyroscope (FOG) with respect to the parameters of the super luminescent emission source based on doped optical fiber with rare earth elements (Super luminescent Fiber Source, SFS), argument the pumping rate election of the SFS to obtain characteristics limits of the FOG sensibility. By using this type of emission source in the FOG is recommend to use the rate when the direction of the pumping signal coincide with the super luminescent signal. The most results are the proposition and argumentation of the SFS election as emission source to be use in the FOG of the phase type. Such a decision allow to increase the characteristics of the FOG sensibility in comparison with the use of luminescent source of semiconductors emission which are extensively used in the present time. The use of emission source of the SFS type allow to come closer to the threshold of the obtained sensibility limit (detection limit) which is determined with the shot noise. (Author)

  11. Quantum mechanics the theoretical minimum

    CERN Document Server

    Susskind, Leonard

    2014-01-01

    From the bestselling author of The Theoretical Minimum, an accessible introduction to the math and science of quantum mechanicsQuantum Mechanics is a (second) book for anyone who wants to learn how to think like a physicist. In this follow-up to the bestselling The Theoretical Minimum, physicist Leonard Susskind and data engineer Art Friedman offer a first course in the theory and associated mathematics of the strange world of quantum mechanics. Quantum Mechanics presents Susskind and Friedman’s crystal-clear explanations of the principles of quantum states, uncertainty and time dependence, entanglement, and particle and wave states, among other topics. An accessible but rigorous introduction to a famously difficult topic, Quantum Mechanics provides a tool kit for amateur scientists to learn physics at their own pace.

  12. Study of boron detection limit using the in-air PIGE set-up at LAMFI-USP

    Energy Technology Data Exchange (ETDEWEB)

    Moro, M. V.; Silva, T. F.; Trindade, G. F.; Added, N.; Tabacniks, M. H. [Institute of Physics, University of São Paulo, SP (Brazil)

    2014-11-11

    The quantification of small amounts of boron in materials is of extreme importance in different areas of materials science. Boron is an important contaminant and also a silicon dopant in the semiconductor industry. Boron is also extensively used in nuclear power plants, either for neutron shielding or for safety control and boron is an essential nutrient for life, either vegetable or animal. The production of silicon solar cells, by refining metallurgical-grade silicon (MG-Si) requires the control and reduction of several silicon contaminants to very low concentration levels. Boron is one of the contaminants of solar-grade silicon (SG-Si) that must be controlled and quantified at sub-ppm levels. In the metallurgical purification, boron quantification is usually made by Inductive Coupled Plasma Mass Spectrometry, (ICP-MS) but the results need to be verified by an independent analytical method. In this work we present the results of the analysis of silicon samples by Particle Induced Gamma-Ray Emission (PIGE) aiming the quantification of low concentrations of boron. PIGE analysis was carried out using the in-air external beam line of the Laboratory for Materials Analysis with Ion Beams (LAMFI-USP) by the {sup 10}B(p,αγ({sup 7}Be nuclear reaction, and measuring the 429 keV γ-ray. The in-air PIGE measurements at LAMFI have a quantification limit of the order of 10{sup 16} at/cm{sup 2}.

  13. Study of boron detection limit using the in-air PIGE set-up at LAMFI-USP

    Science.gov (United States)

    Moro, M. V.; Silva, T. F.; Trindade, G. F.; Added, N.; Tabacniks, M. H.

    2014-11-01

    The quantification of small amounts of boron in materials is of extreme importance in different areas of materials science. Boron is an important contaminant and also a silicon dopant in the semiconductor industry. Boron is also extensively used in nuclear power plants, either for neutron shielding or for safety control and boron is an essential nutrient for life, either vegetable or animal. The production of silicon solar cells, by refining metallurgical-grade silicon (MG-Si) requires the control and reduction of several silicon contaminants to very low concentration levels. Boron is one of the contaminants of solar-grade silicon (SG-Si) that must be controlled and quantified at sub-ppm levels. In the metallurgical purification, boron quantification is usually made by Inductive Coupled Plasma Mass Spectrometry, (ICP-MS) but the results need to be verified by an independent analytical method. In this work we present the results of the analysis of silicon samples by Particle Induced Gamma-Ray Emission (PIGE) aiming the quantification of low concentrations of boron. PIGE analysis was carried out using the in-air external beam line of the Laboratory for Materials Analysis with Ion Beans (LAMFI-USP) by the 10B ( p ,αγ(7Be nuclear reaction, and measuring the 429 keV γ-ray. The in-air PIGE measurements at LAMFI have a quantification limit of the order of 1016 at/cm2.

  14. Study of boron detection limit using the in-air PIGE set-up at LAMFI-USP

    International Nuclear Information System (INIS)

    Moro, M. V.; Silva, T. F.; Trindade, G. F.; Added, N.; Tabacniks, M. H.

    2014-01-01

    The quantification of small amounts of boron in materials is of extreme importance in different areas of materials science. Boron is an important contaminant and also a silicon dopant in the semiconductor industry. Boron is also extensively used in nuclear power plants, either for neutron shielding or for safety control and boron is an essential nutrient for life, either vegetable or animal. The production of silicon solar cells, by refining metallurgical-grade silicon (MG-Si) requires the control and reduction of several silicon contaminants to very low concentration levels. Boron is one of the contaminants of solar-grade silicon (SG-Si) that must be controlled and quantified at sub-ppm levels. In the metallurgical purification, boron quantification is usually made by Inductive Coupled Plasma Mass Spectrometry, (ICP-MS) but the results need to be verified by an independent analytical method. In this work we present the results of the analysis of silicon samples by Particle Induced Gamma-Ray Emission (PIGE) aiming the quantification of low concentrations of boron. PIGE analysis was carried out using the in-air external beam line of the Laboratory for Materials Analysis with Ion Beams (LAMFI-USP) by the 10 B(p,αγ( 7 Be nuclear reaction, and measuring the 429 keV γ-ray. The in-air PIGE measurements at LAMFI have a quantification limit of the order of 10 16 at/cm 2

  15. Improvements on Near Real Time Detection of Volcanic Ash Emissions for Emergency Monitoring with Limited Satellite Bands

    Directory of Open Access Journals (Sweden)

    Torge Steensen

    2015-03-01

    Full Text Available Quantifying volcanic ash emissions syneruptively is an important task for the global aviation community. However, due to the near real time nature of volcano monitoring, many parameters important for accurate ash mass estimates cannot be obtained easily. Even when using the best possible estimates of those parameters, uncertainties associated with the ash masses remain high, especially if the satellite data is only available in the traditional 10.8 and 12.0 μm bands. To counteract this limitation, we developed a quantitative comparison between the ash extents in satellite and model data. The focus is the manual cloud edge definition based on the available satellite reverse absorption (RA data as well as other knowledge like pilot reports or ground-based observations followed by an application of the Volcanic Ash Retrieval on the defined subset with an RA threshold of 0 K. This manual aspect, although subjective to the experience of the observer, can show a significant improvement as it provides the ability to highlight ash that otherwise would be obscured by meteorological clouds or, by passing over different surfaces with unaccounted temperatures, might be lost entirely and thus remains undetectable for an automated satellite approach. We show comparisons to Volcanic Ash Transport and Dispersion models and outline a quantitative match as well as percentages of overestimates based on satellite or dispersion model data which can be converted into a level of reliability for near real time volcano monitoring. 

  16. Understanding the Minimum Wage: Issues and Answers.

    Science.gov (United States)

    Employment Policies Inst. Foundation, Washington, DC.

    This booklet, which is designed to clarify facts regarding the minimum wage's impact on marketplace economics, contains a total of 31 questions and answers pertaining to the following topics: relationship between minimum wages and poverty; impacts of changes in the minimum wage on welfare reform; and possible effects of changes in the minimum wage…

  17. 5 CFR 551.301 - Minimum wage.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Minimum wage. 551.301 Section 551.301... FAIR LABOR STANDARDS ACT Minimum Wage Provisions Basic Provision § 551.301 Minimum wage. (a)(1) Except... employees wages at rates not less than the minimum wage specified in section 6(a)(1) of the Act for all...

  18. The Capabilities and Limitation of Remote Visual Methods to Detect Service-Induced Cracks in Reactor Components

    International Nuclear Information System (INIS)

    Cumblidge, Stephen E.; Doctor, Steven R.; Anderson, Michael T.

    2006-01-01

    detect cracks of various widths under ideal conditions.

  19. Setting a minimum age for juvenile justice jurisdiction in California.

    Science.gov (United States)

    S Barnert, Elizabeth; S Abrams, Laura; Maxson, Cheryl; Gase, Lauren; Soung, Patricia; Carroll, Paul; Bath, Eraka

    2017-03-13

    Purpose Despite the existence of minimum age laws for juvenile justice jurisdiction in 18 US states, California has no explicit law that protects children (i.e. youth less than 12 years old) from being processed in the juvenile justice system. In the absence of a minimum age law, California lags behind other states and international practice and standards. The paper aims to discuss these issues. Design/methodology/approach In this policy brief, academics across the University of California campuses examine current evidence, theory, and policy related to the minimum age of juvenile justice jurisdiction. Findings Existing evidence suggests that children lack the cognitive maturity to comprehend or benefit from formal juvenile justice processing, and diverting children from the system altogether is likely to be more beneficial for the child and for public safety. Research limitations/implications Based on current evidence and theory, the authors argue that minimum age legislation that protects children from contact with the juvenile justice system and treats them as children in need of services and support, rather than as delinquents or criminals, is an important policy goal for California and for other national and international jurisdictions lacking a minimum age law. Originality/value California has no law specifying a minimum age for juvenile justice jurisdiction, meaning that young children of any age can be processed in the juvenile justice system. This policy brief provides a rationale for a minimum age law in California and other states and jurisdictions without one.

  20. Setting a minimum age for juvenile justice jurisdiction in California

    Science.gov (United States)

    Barnert, Elizabeth S.; Abrams, Laura S.; Maxson, Cheryl; Gase, Lauren; Soung, Patricia; Carroll, Paul; Bath, Eraka

    2018-01-01

    Purpose Despite the existence of minimum age laws for juvenile justice jurisdiction in 18 US states, California has no explicit law that protects children (i.e. youth less than 12 years old) from being processed in the juvenile justice system. In the absence of a minimum age law, California lags behind other states and international practice and standards. The paper aims to discuss these issues. Design/methodology/approach In this policy brief, academics across the University of California campuses examine current evidence, theory, and policy related to the minimum age of juvenile justice jurisdiction. Findings Existing evidence suggests that children lack the cognitive maturity to comprehend or benefit from formal juvenile justice processing, and diverting children from the system altogether is likely to be more beneficial for the child and for public safety. Research limitations/implications Based on current evidence and theory, the authors argue that minimum age legislation that protects children from contact with the juvenile justice system and treats them as children in need of services and support, rather than as delinquents or criminals, is an important policy goal for California and for other national and international jurisdictions lacking a minimum age law. Originality/value California has no law specifying a minimum age for juvenile justice jurisdiction, meaning that young children of any age can be processed in the juvenile justice system. This policy brief provides a rationale for a minimum age law in California and other states and jurisdictions without one. Paper type Conceptual paper PMID:28299968

  1. First Limit on the Direct Detection of Lightly Ionizing Particles for Electric Charge as Low as e /1000 with the Majorana Demonstrator

    Science.gov (United States)

    Alvis, S. I.; Arnquist, I. J.; Avignone, F. T.; Barabash, A. S.; Barton, C. J.; Bertrand, F. E.; Brudanin, V.; Busch, M.; Buuck, M.; Caldwell, T. S.; Chan, Y.-D.; Christofferson, C. D.; Chu, P.-H.; Cuesta, C.; Detwiler, J. A.; Dunagan, C.; Efremenko, Yu.; Ejiri, H.; Elliott, S. R.; Gilliss, T.; Giovanetti, G. K.; Green, M. P.; Gruszko, J.; Guinn, I. S.; Guiseppe, V. E.; Haufe, C. R.; Hehn, L.; Henning, R.; Hoppe, E. W.; Howe, M. A.; Konovalov, S. I.; Kouzes, R. T.; Lopez, A. M.; Martin, R. D.; Massarczyk, R.; Meijer, S. J.; Mertens, S.; Myslik, J.; O'Shaughnessy, C.; Othman, G.; Pettus, W.; Poon, A. W. P.; Radford, D. C.; Rager, J.; Reine, A. L.; Rielage, K.; Robertson, R. G. H.; Ruof, N. W.; Shanks, B.; Shirchenko, M.; Suriano, A. M.; Tedeschi, D.; Varner, R. L.; Vasilyev, S.; Vorren, K.; White, B. R.; Wilkerson, J. F.; Wiseman, C.; Xu, W.; Yakushev, E.; Yu, C.-H.; Yumatov, V.; Zhitnikov, I.; Zhu, B. X.; Majorana Collaboration

    2018-05-01

    The Majorana Demonstrator is an ultralow-background experiment searching for neutrinoless double-beta decay in 76Ge. The heavily shielded array of germanium detectors, placed nearly a mile underground at the Sanford Underground Research Facility in Lead, South Dakota, also allows searches for new exotic physics. Free, relativistic, lightly ionizing particles with an electrical charge less than e are forbidden by the standard model but predicted by some of its extensions. If such particles exist, they might be detected in the Majorana Demonstrator by searching for multiple-detector events with individual-detector energy depositions down to 1 keV. This search is background-free, and no candidate events have been found in 285 days of data taking. New direct-detection limits are set for the flux of lightly ionizing particles for charges as low as e /1000 .

  2. The Cu-MOF-199/single-walled carbon nanotubes modified electrode for simultaneous determination of hydroquinone and catechol with extended linear ranges and lower detection limits

    International Nuclear Information System (INIS)

    Zhou, Jian; Li, Xi; Yang, Linlin; Yan, Songlin; Wang, Mengmeng; Cheng, Dan; Chen, Qi; Dong, Yulin; Liu, Peng; Cai, Weiquan; Zhang, Chaocan

    2015-01-01

    A novel electrochemical sensor based on Cu-MOF-199 [Cu-MOF-199 = Cu 3 (BTC) 2 (BTC = 1,3,5-benzenetricarboxylicacid)] and SWCNTs (single-walled carbon nanotubes) was fabricated for the simultaneous determination of hydroquinone (HQ) and catechol (CT). The modification procedure was carried out through casting SWCNTs on the bare glassy carbon electrode (GCE) and followed by the electrodeposition of Cu-MOF-199 on the SWCNTs modified electrode. Cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) were performed to characterize the electrochemical performance and surface characteristics of the as-prepared sensor. The composite electrode exhibited an excellent electrocatalytic activity with increased electrochemical signals towards the oxidation of HQ and CT, owing to the synergistic effect of SWCNTs and Cu-MOF-199. Under the optimized condition, the linear response range were from 0.1 to 1453 μmol L −1 (R HQ  = 0.9999) for HQ and 0.1–1150 μmol L −1 (R CT  = 0.9990) for CT. The detection limits for HQ and CT were as low as 0.08 and 0.1 μmol L −1 , respectively. Moreover, the modified electrode presented the good reproducibility and the excellent anti-interference performance. The analytical performance of the developed sensor for the simultaneous detection of HQ and CT had been evaluated in practical samples with satisfying results. - Highlights: • Cu-MOF-199/SWCNTs/GCE was facilely fabricated by the electrodeposition on SWCNTs/GCE. • An electrochemical sensor for detecting HQ and CT was constructed based on this modified electrode. • The proposed electrochemical sensor showed an extended linear range and lower detection limits. • The proposed electrochemical sensor had an excellent stability and reproducibility.

  3. Photoinduced triplet-state electron transfer of platinum porphyrin: a one-step direct method for sensing iodide with an unprecedented detection limit

    KAUST Repository

    Masih, Dilshad

    2015-02-05

    Here, we report for the first time a one-step direct method for sensing halides in aqueous solution using phosphorescence quenching of platinum-cationic porphyrin. This method offers an easy, rapid, environmentally friendly, ultra-sensitive (with a previously unattained detection limit of 1 × 10−12 M) and economical method for the determination of iodide. To fully understand the reaction mechanism responsible for the phosphorescence quenching process, we have employed cutting-edge time-resolved laser spectroscopy with broadband capabilities.

  4. Use of oxidative and reducing vapor generation for reducing the detection limits of iodine in biological samples by inductively coupled plasma atomic emission spectrometry

    International Nuclear Information System (INIS)

    Vtorushina, Eh.A.; Saprykin, A.I.; Knapp, G.

    2009-01-01

    Procedures of microwave combustion in an oxygen flow and microwave acid decomposition of biological samples were optimized for the subsequent determination of iodine. A new method was proposed for the generation of molecular iodine from periodate iona using hydrogen peroxide as a reductant. Procedures were developed for determining iodine in biological samples by inductively coupled plasma atomic emission spectrometry (ICP-AES) using oxidative and reducing vapor generation; these allowed the detection limit for iodine to be lowered by 3-4 orders of magnitude. The developed procedures were used to analyze certified reference materials of milk (Skim Milk Powder BCR 150) and seaweed (Sea Lettuce BCR 279) and a Supradyn vitamin complex

  5. DETERMINATION OF LIMIT DETECTION OF THE ELEMENTS N, P, K, Si, Al, Fe, Cu, Cd, WITH FAST NEUTRON ACTIVATION USING NEUTRON GENERATOR

    OpenAIRE

    Sunardi, Sunardi; Muryono, Muryono

    2010-01-01

    Determination of limit detection of the elements N, P, K, Si, Al, Fe, Cu, Cd, with fast neutron activation using neutron generator has been done.  Samples prepared from SRM 2704, N, P, K elements from MERCK, Cu, Cd, Al from activation foil made in San Carlos, weighted and packed for certain weight then iradiated during 30 minutes with 14 MeV fast neutron using the neutron generator and then counted with gamma spectrometry (accuspec).  At this research condition of neutron generator was set at...

  6. Non-destructive micro-X-ray diffraction analysis of painted artefacts: Determination of detection limits for the chromium oxide-zinc oxide matrix

    International Nuclear Information System (INIS)

    Nel, P.; Lau, D.; Hay, D.; Wright, N.

    2006-01-01

    The development of micro-X-ray diffraction (micro-XRD) enables non-destructive, in situ analysis of crystalline pigments on artworks and archaeological objects. Pigments with X-ray diffraction patterns with large peak intensities may complicate the identification of other components with lower absorption coefficients, especially if present in low concentrations in the paint sample. Investigation of this issue involved: (1) micro-XRD examination and analysis of the amorphous and crystalline phases of fifteen pigment films and (2) micro-XRD examination and semi-quantitative analysis of various chromium oxide-zinc oxide mixtures, which established detection limits as low as 5 ± 2%

  7. Improvement in limit of detection in particle induced X-ray emission by means of rise time and pulse shape discrimination

    Energy Technology Data Exchange (ETDEWEB)

    Papp, Tibor E-mail: tibpapp@netscape.nettibpapp@yahoo.ca; Lakatos, Tamas; Nejedly, Zdenek; Campbell, John L

    2002-04-01

    A digital signal processor, based upon high-rate sampling of the preamplifier output, and equipped with rise time and pulse shape discrimination, has been tested in three situations. This processor provided significant improvement of particle induced X-ray emission and X-ray fluorescence detection limits over the state of the art analog processors, depending on the energy and intensity distribution of the X-ray spectra. Additionally it had a superior performance when measurements were performed in an environment of large electronic noise and in large nuclear background environment. It has also improved the reduction of several artifacts in X-ray spectra.

  8. Detecting position using ARKit II: generating position-time graphs in real-time and further information on limitations of ARKit

    Science.gov (United States)

    Dilek, Ufuk; Erol, Mustafa

    2018-05-01

    ARKit is a framework which allows developers to create augmented reality apps for the iPhone and iPad. In a previous study, we had shown that it could be used to detect position in educational physics experiments and emphasized that the ability to provide position data in real-time was one of the prominent features of this newly emerging technology. In this study, we demonstrate an example of how real-time data acquisition can be employed in educational settings, report some of the limitations of ARKit and how we have overcome these limitations. By means of ARKit or a similar framework, ordinary mobile devices can be adapted for use in microcomputer-based lab activities.

  9. Lower limits of spin detection efficiency for two-parameter two-qubit (TPTQ) states with non-ideal ferromagnetic detectors

    Science.gov (United States)

    Majd, Nayereh; Ghasemi, Zahra

    2016-10-01

    We have investigated a TPTQ state as an input state of a non-ideal ferromagnetic detectors. Minimal spin polarization required to demonstrate spin entanglement according to entanglement witness and CHSH inequality with respect to (w.r.t.) their two free parameters have been found, and we have numerically shown that the entanglement witness is less stringent than the direct tests of Bell's inequality in the form of CHSH in the entangled limits of its free parameters. In addition, the lower limits of spin detection efficiency fulfilling secure cryptographic key against eavesdropping have been derived. Finally, we have considered TPTQ state as an output of spin decoherence channel and the region of ballistic transmission time w.r.t. spin relaxation time and spin dephasing time has been found.

  10. Assessment of the production of J/psi, related to minimum bias events, in In-In collisions at 158 GeV/c per nucleon detected with the vertex telescope at the N60 experiment

    International Nuclear Information System (INIS)

    Chapsal, L.

    2009-01-01

    Theoretical physics considers, at the first start of the world, that matter may have existed as a Quark and Gluon Plasma (QGP). The heavy ion collisions in ultra-relativist energies are used to recreate this deconfined state of matter. NA50 experiment at CERN put into evidence, between others, the existence of an abnormal J/ψ suppression in its dimuon channel for the most central lead-lead collisions. NA60 collaboration allowed, with an improved precision, to ameliorate and to supplement NA50 results. One of the most remarkable results of this experiment was to show that the dimuon excess, noticed in the intermediate masses, was induced by direct dimuons what could be the first evidence for thermal dimuons. The job of this work is related to NA60 experiment for In-In collisions at 158 GeV/c by nucleon and concerns the production of the resonance J/ψ according to centrality. After corrections of the effects of acceptance and efficiencies, the centrality is deduced from the trace multiplicity by using the code of simulation VENUS. Production of J/ψ is normalized to minimum bias events which are insensible to the production of QGP. Results point out that production of J/ψ in In-In collisions is compatible with nuclear absorption with a cross section σ = (4.18 ± 0.35) mb. There is no therefore abnormal suppression, whatever the centrality is. This study concerned only a fraction of In-In data, complete statistics would allow more accuracy in this result. (author)

  11. Evaluation of uncertainty and detection limits in 210Pb and 210Po measurement in water by alpha spectrometry using 210Po spontaneous deposition onto a silver disk

    International Nuclear Information System (INIS)

    Fernández, Pedro L.; Gómez, José; Ródenas, Carmen

    2012-01-01

    An easy and accurate method for the determination of 210 Pb and 210 Po in water using 210 Po spontaneous deposition onto a silver disk is proposed and assessed for its detection capabilities according to the ISO Guide for the expression of uncertainty in measurement (GUM) and ISO Standard 11929-7 concerning the evaluation of the characteristic limits for ionizing radiation measurements. The method makes no assumption on the initial values of the activity concentrations of 210 Pb, 210 Bi and 210 Po in the sample to be analyzed, and is based on the alpha spectrometric measurement of 210 Po in two different aliquots: the first one measured five weeks after the sampling date to ensure radioactive equilibrium between 210 Pb and 210 Bi and the second after a sufficient time for the ingrowth of 210 Po from 210 Pb to be significant. As shown, for a recommended time interval of seven months between 210 Po measurements, the applicability of the proposed method is limited to water samples with a 226 Ra to 210 Pb activity ratio C Ra /C Pb ≤4, as usual in natural waters. Using sample and background counting times of 24 h and 240 h, respectively, the detection limit of the activity concentration of each radionuclide at the sampling time for a 1 L sample typically varies between 0.7 and 16 mBq L −1 for 210 Pb in water samples with an initial activity of 210 Po in the range 0–200 mBq L −1 , and between 0.6 and 8.5 mBq L −1 for 210 Po in water samples with an initial activity of 210 Pb in the same range. - Highlights: ► 210 Pb and 210 Po measurement in water by 210 Po spontaneous deposition onto silver disks. ► 210 Pb and 210 Po determination based on 210 Po measurement in two different aliquots. ► Evaluation of characteristic limits in radioactivity measurements using ISO 11929-7. ► 10 Pb - 210 Po detection limits decrease with time elapsed between 210 Po measurements.

  12. Systematic optimization of multiplex zymography protocol to detect active cathepsins K, L, S, and V in healthy and diseased tissue: compromise among limits of detection, reduced time, and resources.

    Science.gov (United States)

    Dumas, Jerald E; Platt, Manu O

    2013-07-01

    Cysteine cathepsins are a family of proteases identified in cancer, atherosclerosis, osteoporosis, arthritis, and a number of other diseases. As this number continues to rise, so does the need for low cost, broad use quantitative assays to detect their activity and can be translated to the clinic in the hospital or in low resource settings. Multiplex cathepsin zymography is one such assay that detects subnanomolar levels of active cathepsins K, L, S, and V in cell or tissue preparations observed as clear bands of proteolytic activity after gelatin substrate SDS-PAGE with conditions optimal for cathepsin renaturing and activity. Densitometric analysis of the zymogram provides quantitative information from this low cost assay. After systematic modifications to optimize cathepsin zymography, we describe reduced electrophoresis time from 2 h to 10 min, incubation assay time from overnight to 4 h, and reduced minimal tissue protein necessary while maintaining sensitive detection limits; an evaluation of the pros and cons of each modification is also included. We further describe image acquisition by Smartphone camera, export to Matlab, and densitometric analysis code to quantify and report cathepsin activity, adding portability and replacing large scale, darkbox imaging equipment that could be cost prohibitive in limited resource settings.

  13. Systematic optimization of multiplex zymography protocol to detect active cathepsins K, L, S, and V in healthy and diseased tissue: compromise between limits of detection, reduced time, and resources

    Science.gov (United States)

    Dumas, Jerald E.; Platt, Manu O.

    2013-01-01

    Cysteine cathepsins are a family of proteases identified in cancer, atherosclerosis, osteoporosis, arthritis and a number of other diseases. As this number continues to rise, so does the need for low cost, broad use quantitative assays to detect their activity and can be translated to the clinic in the hospital or in low resource settings. Multiplex cathepsin zymography is one such assay that detects subnanomolar levels of active cathepsins K, L, S, and V in cell or tissue preparations observed as cleared bands of proteolytic activity after gelatin substrate SDS-PAGE with conditions optimal for cathepsin renaturing and activity. Densitometric analysis of the zymogram provides quantitative information from this low cost assay. After systematic modifications to optimize cathepsin zymography, we describe reduced electrophoresis time from 2 hours to 10 minutes, incubation assay time from overnight to 4 hours, and reduced minimal tissue protein necessary while maintaining sensitive detection limits; an evaluation of the pros and cons of each modification is also included. We further describe image acquisition by smartphone camera, export to Matlab, and densitometric analysis code to quantify and report cathepsin activity, adding portability and replacing large scale, darkbox imaging equipment that could be cost prohibitive in limited resource settings. PMID:23532386

  14. Improved Sensitivity with Low Limit of Detection of a Hydrogen Gas Sensor Based on rGO-Loaded Ni-Doped ZnO Nanostructures.

    Science.gov (United States)

    Bhati, Vijendra Singh; Ranwa, Sapana; Rajamani, Saravanan; Kumari, Kusum; Raliya, Ramesh; Biswas, Pratim; Kumar, Mahesh

    2018-04-04

    We report enhanced hydrogen-gas-sensing performance of a Ni-doped ZnO sensor decorated with the optimum concentration of reduced graphene oxide (rGO). Ni-doped ZnO nanoplates were grown by radio frequency sputtering, rGO was synthesized by Hummer's method and decorated by the drop cast method of various concentration of rGO (0-1.5 wt %). The current-voltage characteristics of the rGO-loaded sensor are highly influenced by the loading concentration of rGO, where current conduction decreases and sensor resistance increases as the rGO concentration is increased up to 0.75 wt % because of the formation of various Schottky heterojunctions at rGO/ZnO interfaces. With the combined effect of more active site availability and formation of various p-n heterojunctions due to the optimum loading concentration of rGO (0.75 wt %), the sensor shows the maximum sensing response of ∼63.8% for 100 ppm hydrogen at moderate operating temperature (150 °C). The rGO-loaded sensors were able to detect a minimum of 1 ppm hydrogen concentration and showed high selectivity. However, a further increase in the rGO concentration (1.5 wt %) leads to the reduction of the relative response of hydrogen gas, ascribed to the formation of interconnections of rGO between electrodes. Therefore, it reduces the total resistance of the sensor and minimizes the effect of p-n heterojunction on sensor response.

  15. Statistical methods for assays with limits of detection: Serum bile acid as a differentiator between patients with normal colons, adenomas, and colorectal cancer

    Directory of Open Access Journals (Sweden)

    Bonnie LaFleur

    2011-01-01

    Full Text Available In analytic chemistry a detection limit (DL is the lowest measurable amount of an analyte that can be distinguished from a blank; many biomedical measurement technologies exhibit this property. From a statistical perspective, these data present inferential challenges because instead of precise measures, one only has information that the value is somewhere between 0 and the DL (below detection limit, BDL. Substitution of BDL values, with 0 or the DL can lead to biased parameter estimates and a loss of statistical power. Statistical methods that make adjustments when dealing with these types of data, often called left-censored data, are available in many commercial statistical packages. Despite this availability, the use of these methods is still not widespread in biomedical literature. We have reviewed the statistical approaches of dealing with BDL values, and used simulations to examine the performance of the commonly used substitution methods and the most widely available statistical methods. We have illustrated these methods using a study undertaken at the Vanderbilt-Ingram Cancer Center, to examine the serum bile acid levels in patients with colorectal cancer and adenoma. We have found that the modern methods for BDL values identify disease-related differences that are often missed, with statistically naive approaches.

  16. Conducting electrospun fibres with polyanionic grafts as highly selective, label-free, electrochemical biosensor with a low detection limit for non-Hodgkin lymphoma gene.

    Science.gov (United States)

    Kerr-Phillips, Thomas E; Aydemir, Nihan; Chan, Eddie Wai Chi; Barker, David; Malmström, Jenny; Plesse, Cedric; Travas-Sejdic, Jadranka

    2018-02-15

    A highly selective, label-free sensor for the non-Hodgkin lymphoma gene, with an aM detection limit, utilizing electrochemical impedance spectroscopy (EIS) is presented. The sensor consists of a conducting electrospun fibre mat, surface-grafted with poly(acrylic acid) (PAA) brushes and a conducting polymer sensing element with covalently attached oligonucleotide probes. The sensor was fabricated from electrospun NBR rubber, embedded with poly(3,4-ethylenedioxythiophene) (PEDOT), followed by grafting poly(acrylic acid) brushes and then electrochemically polymerizing a conducting polymer monomer with ssDNA probe sequence pre-attached. The resulting non-Hodgkin lymphoma gene sensor showed a detection limit of 1aM (1 × 10 -18 mol/L), more than 400 folds lower compared to a thin-film analogue. The sensor presented extraordinary selectivity, with only 1%, 2.7% and 4.6% of the signal recorded for the fully non-complimentary, T-A and G-C base mismatch oligonucleotide sequences, respectively. We suggest that such greatly enhanced selectivity is due to the presence of negatively charged carboxylic acid moieties from PAA grafts that electrostatically repel the non-complementary and mismatch DNA sequences, overcoming the non-specific binding. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Multielement detection limits and sample nebulization efficiencies of an improved ultrasonic nebulizer and a conventional pneumatic nebulizer in inductively coupled plasma-atomic emission spectrometry

    International Nuclear Information System (INIS)

    Olson, K.W.; Haas, W.J. Jr.; Fassel, V.A.

    1977-01-01

    Two important aspects of the analytical performance of a newly developed ultrasonic nebulizer and a specially designed pneumatic nebulizer have been compared for use in inductively coupled plasma--atomic emission spectroscopy (ICP-AES). The ultrasonic nebulizer, when combined with a conventional aerosol desolvation apparatus, provided an order of magnitude or more improvement in simultaneous multielement detection limits as compared to those obtained when the pneumatic nebulizer was used either with or without desolvation. Application of a novel method for direct measurement of the overall efficiency of nebulization to the two systems showed that an approximately tenfold greater rate of sample delivery to the plasma torch was primarily responsible for the superior detection limits afforded by the ultrasonic nebulizer. A unique feature of the ultrasonic nebulizer described is the protection against chemical attack which is achieved by completely enclosing the transducer in an acoustically coupled borosilicate glass cylinder. Direct sample introduction, convenient sample change, and rapid cleanout are other important characteristics of the system which make it an attractive alternate to pneumatic nebulizer systems

  18. Ultrahigh sensitivity made simple: nanoplasmonic label-free biosensing with an extremely low limit-of-detection for bacterial and cancer diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S; Svedendahl, M; Kaell, M; Gunnarsson, L; Dmitriev, A, E-mail: alexd@chalmers.s [Department of Applied Physics, Chalmers University of Technology, 41296 Goeteborg (Sweden)

    2009-10-28

    We present a simple and robust scheme for biosensing with an ultralow limit-of-detection down to several pg cm{sup -2} (or several tens of attomoles cm{sup -2}) based on optical label-free biodetection with localized surface plasmon resonances. The scheme utilizes cost-effective optical components and comprises a white light source, a properly functionalized sensor surface enclosed in a simple fluidics chip, and a spectral analyzer. The sensor surface is produced by a bottom-up nanofabrication technique with hole mask colloidal lithography. Despite its simplicity, the method is able to reliably detect protein-protein binding events at low picomolar and femtomolar concentrations, which is exemplified by the label-free detection of the extracellular adherence protein (EAP) found on the outer surface of the bacterium Staphylococcus aureus and of prostate-specific antigen (PSA), which is believed to be a prostate cancer marker. These experiments pave the way towards an ultra-sensitive yet compact biodetection platform for point-of-care diagnostics applications.

  19. The minimum yield in channeling

    International Nuclear Information System (INIS)

    Uguzzoni, A.; Gaertner, K.; Lulli, G.; Andersen, J.U.

    2000-01-01

    A first estimate of the minimum yield was obtained from Lindhard's theory, with the assumption of a statistical equilibrium in the transverse phase-space of channeled particles guided by a continuum axial potential. However, computer simulations have shown that this estimate should be corrected by a fairly large factor, C (approximately equal to 2.5), called the Barrett factor. We have shown earlier that the concept of a statistical equilibrium can be applied to understand this result, with the introduction of a constraint in phase-space due to planar channeling of axially channeled particles. Here we present an extended test of these ideas on the basis of computer simulation of the trajectories of 2 MeV α particles in Si. In particular, the gradual trend towards a full statistical equilibrium is studied. We also discuss the introduction of this modification of standard channeling theory into descriptions of the multiple scattering of channeled particles (dechanneling) by a master equation and show that the calculated minimum yields are in very good agreement with the results of a full computer simulation

  20. Minimum Bias Trigger in ATLAS

    International Nuclear Information System (INIS)

    Kwee, Regina

    2010-01-01

    Since the restart of the LHC in November 2009, ATLAS has collected inelastic pp collisions to perform first measurements on charged particle densities. These measurements will help to constrain various models describing phenomenologically soft parton interactions. Understanding the trigger efficiencies for different event types are therefore crucial to minimize any possible bias in the event selection. ATLAS uses two main minimum bias triggers, featuring complementary detector components and trigger levels. While a hardware based first trigger level situated in the forward regions with 2.2 < |η| < 3.8 has been proven to select pp-collisions very efficiently, the Inner Detector based minimum bias trigger uses a random seed on filled bunches and central tracking detectors for the event selection. Both triggers were essential for the analysis of kinematic spectra of charged particles. Their performance and trigger efficiency measurements as well as studies on possible bias sources will be presented. We also highlight the advantage of these triggers for particle correlation analyses. (author)

  1. Microbial oceanography of anoxic oxygen minimum zones

    DEFF Research Database (Denmark)

    Ulloa, Osvaldo; Canfield, Donald E; DeLong, Edward F

    2012-01-01

    oxide (N(2)O) gases. Anaerobic microbial processes, including the two pathways of N(2) production, denitrification and anaerobic ammonium oxidation, are oxygen-sensitive, with some occurring only under strictly anoxic conditions. The detection limit of the usual method (Winkler titrations) for measuring...

  2. Clinical Application of Picodroplet Digital PCR Technology for Rapid Detection of EGFR T790M in Next-Generation Sequencing Libraries and DNA from Limited Tumor Samples.

    Science.gov (United States)

    Borsu, Laetitia; Intrieri, Julie; Thampi, Linta; Yu, Helena; Riely, Gregory; Nafa, Khedoudja; Chandramohan, Raghu; Ladanyi, Marc; Arcila, Maria E

    2016-11-01

    Although next-generation sequencing (NGS) is a robust technology for comprehensive assessment of EGFR-mutant lung adenocarcinomas with acquired resistance to tyrosine kinase inhibitors, it may not provide sufficiently rapid and sensitive detection of the EGFR T790M mutation, the most clinically relevant resistance biomarker. Here, we describe a digital PCR (dPCR) assay for rapid T790M detection on aliquots of NGS libraries prepared for comprehensive profiling, fully maximizing broad genomic analysis on limited samples. Tumor DNAs from patients with EGFR-mutant lung adenocarcinomas and acquired resistance to epidermal growth factor receptor inhibitors were prepared for Memorial Sloan-Kettering-Integrated Mutation Profiling of Actionable Cancer Targets sequencing, a hybrid capture-based assay interrogating 410 cancer-related genes. Precapture library aliquots were used for rapid EGFR T790M testing by dPCR, and results were compared with NGS and locked nucleic acid-PCR Sanger sequencing (reference high sensitivity method). Seventy resistance samples showed 99% concordance with the reference high sensitivity method in accuracy studies. Input as low as 2.5 ng provided a sensitivity of 1% and improved further with increasing DNA input. dPCR on libraries required less DNA and showed better performance than direct genomic DNA. dPCR on NGS libraries is a robust and rapid approach to EGFR T790M testing, allowing most economical utilization of limited material for comprehensive assessment. The same assay can also be performed directly on any limited DNA source and cell-free DNA. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  3. ICG-assisted blood vessel detection during stereotactic neurosurgery: simulation study on excitation power limitations due to thermal effects in human brain tissue.

    Science.gov (United States)

    Rühm, Adrian; Göbel, Werner; Sroka, Ronald; Stepp, Herbert

    2014-09-01

    Intraoperative blood vessel detection based on intraluminal indocyanin-green (ICG) would allow to minimize the risk of blood vessel perforation during stereotactic brain tumor biopsy. For a fiber-based approach compatible with clinical conditions, the maximum tolerable excitation light power was derived from simulations of the thermal heat load on the tissue. Using the simulation software LITCIT, the temperature distribution in human brain tissue was calculated as a function of time for realistic single-fiber probes (0.72mm active diameter, numerical aperture 0.35, optional focusing to 0.29mm diameter) and for the optimum ICG excitation wavelength of 785nm. The asymptotic maximum temperature in the simulated tissue region was derived for different radiant fluxes at the distal fiber end. Worst case values were assumed for all other parameters. In addition to homogeneous (normal and tumor) brain tissue with homogeneous blood perfusion, models with localized extra blood vessels incorporated ahead of the distal fiber end were investigated. If one demands that destruction of normal brain tissue must be excluded by limiting the tissue heating to 42°C, then the radiant flux at the distal fiber end must be limited to 33mW with and 43mW without focusing. When considering extra blood vessels of 0.1mm diameter incorporated into homogeneously perfused brain tissue, the tolerable radiant flux is reduced to 22mW with and 32mW without focusing. The threshold value according to legal laser safety regulations for human skin tissue is 28.5mW. For the envisaged modality of blood vessel detection, light power limits for an application-relevant fiber configuration were determined and found to be roughly consistent with present legal regulations for skin tissue. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Quantifying environmental limiting factors on tree cover using geospatial data.

    Directory of Open Access Journals (Sweden)

    Jonathan A Greenberg

    Full Text Available Environmental limiting factors (ELFs are the thresholds that determine the maximum or minimum biological response for a given suite of environmental conditions. We asked the following questions: 1 Can we detect ELFs on percent tree cover across the eastern slopes of the Lake Tahoe Basin, NV? 2 How are the ELFs distributed spatially? 3 To what extent are unmeasured environmental factors limiting tree cover? ELFs are difficult to quantify as they require significant sample sizes. We addressed this by using geospatial data over a relatively large spatial extent, where the wall-to-wall sampling ensures the inclusion of rare data points which define the minimum or maximum response to environmental factors. We tested mean temperature, minimum temperature, potential evapotranspiration (PET and PET minus precipitation (PET-P as potential limiting factors on percent tree cover. We found that the study area showed system-wide limitations on tree cover, and each of the factors showed evidence of being limiting on tree cover. However, only 1.2% of the total area appeared to be limited by the four (4 environmental factors, suggesting other unmeasured factors are limiting much of the tree cover in the study area. Where sites were near their theoretical maximum, non-forest sites (tree cover < 25% were primarily limited by cold mean temperatures, open-canopy forest sites (tree cover between 25% and 60% were primarily limited by evaporative demand, and closed-canopy forests were not limited by any particular environmental factor. The detection of ELFs is necessary in order to fully understand the width of limitations that species experience within their geographic range.

  5. MEDOF - MINIMUM EUCLIDEAN DISTANCE OPTIMAL FILTER

    Science.gov (United States)

    Barton, R. S.

    1994-01-01

    The Minimum Euclidean Distance Optimal Filter program, MEDOF, generates filters for use in optical correlators. The algorithm implemented in MEDOF follows theory put forth by Richard D. Juday of NASA/JSC. This program analytically optimizes filters on arbitrary spatial light modulators such as coupled, binary, full complex, and fractional 2pi phase. MEDOF optimizes these modulators on a number of metrics including: correlation peak intensity at the origin for the centered appearance of the reference image in the input plane, signal to noise ratio including the correlation detector noise as well as the colored additive input noise, peak to correlation energy defined as the fraction of the signal energy passed by the filter that shows up in the correlation spot, and the peak to total energy which is a generalization of PCE that adds the passed colored input noise to the input image's passed energy. The user of MEDOF supplies the functions that describe the following quantities: 1) the reference signal, 2) the realizable complex encodings of both the input and filter SLM, 3) the noise model, possibly colored, as it adds at the reference image and at the correlation detection plane, and 4) the metric to analyze, here taken to be one of the analytical ones like SNR (signal to noise ratio) or PCE (peak to correlation energy) rather than peak to secondary ratio. MEDOF calculates filters for arbitrary modulators and a wide range of metrics as described above. MEDOF examines the statistics of the encoded input image's noise (if SNR or PCE is selected) and the filter SLM's (Spatial Light Modulator) available values. These statistics are used as the basis of a range for searching for the magnitude and phase of k, a pragmatically based complex constant for computing the filter transmittance from the electric field. The filter is produced for the mesh points in those ranges and the value of the metric that results from these points is computed. When the search is concluded, the

  6. The Unusual Minimum of Cycle 23: Observations and Interpretation

    Science.gov (United States)

    Martens, Petrus C.; Nandy, D.; Munoz-Jaramillo, A.

    2009-05-01

    The current minimum of cycle 23 is unusual in its long duration, the very low level to which Total Solar Irradiance (TSI) has fallen, and the small flux of the open polar fields. The deep minimum of TSI seems to be related to an unprecedented dearth of polar faculae, and hence to the small amount of open flux. Based upon surface flux transport models it has been suggested that the causes of these phenomena may be an unusually vigorous meridional flow, or even a deviation from Joy's law resulting in smaller Joy angles than usual for emerging flux in cycle 23. There is also the possibility of a connection with the recently inferred emergence in polar regions of bipoles that systematically defy Hale's law. Much speculation has been going on as to the consequences of this exceptional minimum: are we entering another global minimum, is this the end of the 80 year period of exceptionally high solar activity, or is this just a statistical hiccup? Dynamo simulations are underway that may help answer this question. As an aside it must be mentioned that the current minimum of TSI puts an upper limit in the TSI input for global climate simulations during the Maunder minimum, and that a possible decrease in future solar activity will result in a very small but not insignificant reduction in the pace of global warming.

  7. Use of environmental TLD data at a nuclear power station to estimate detection limits for radiation exposure due to station operation

    International Nuclear Information System (INIS)

    Lang, E.; Hardeman, J.; Kahn, B.

    1987-01-01

    The environmental radiation monitoring network maintained by the Georgia Department of Natural Resources at the Hatch Nuclear Plant, Baxley, GA, was used to determine the variability in measured background exposures in order to estimate the detection limits for radiation due to station operation. Data were obtained from LiF thermoluminescent dosimeters (TLDs) exposed in sets of four at 46 locations for 16 consecutive quarters from 1982 to 1985. The average exposure for 695 values was 11.8 microC kg-1 y-1 (mR/quarter). At individual locations, the averages of quarterly exposures ranged from 9.3 to 14.3 microC kg-1 y-1 and had standard deviations from 0.8 to 2.2 microC kg-1 y-1 with a typical standard deviation of 1.5 microC kg-1 y-1. The standard deviation due to reading the TLDs and subtracting the transit plus storage exposure, estimated as 0.4 microC kg-1 y-1, contributed only a small fraction of the uncertainty of the mean background; the greater contribution is from temporal fluctuations. There is a spatial pattern of higher background along the Altamaha River but no distinct seasonal pattern. The observation that exposure values at most locations rose and fell in unison suggested a calculational model that adjusts the average exposure level at a location by an increment determined each quarter at control locations. This model reduced the standard deviation for a predicted quarterly background exposure to 0.9 microC kg-1 y-1, with a range of 0.5 to 1.3 microC kg-1 y-1. If the standard deviation of the net value is multiplied by an error probability constant of 3.3 (type I and II errors not greater than 5%), the detection limits range from 2 to 5 microC kg-1 y-1 at the individual locations, with an average of 3 microC kg-1 y-1. This approach or two similar ones described earlier are recommended for improving the detection limit where needed

  8. Detections and Sensitive Upper Limits for Methane and Related Trace Gases on Mars during 2003-2014, and planned extensions in 2016

    Science.gov (United States)

    Mumma, Michael J.; Villanueva, Geronimo L.; Novak, Robert E.

    2015-11-01

    Five groups report methane detections on Mars; all results suggest local release and high temporal variability [1-7]. Our team searched for CH4 on many dates and seasons and detected it on several dates [1, 9, 10]. TLS (Curiosity rover) reported methane upper limits [6], and then detections [7] that were consistent in size with earlier reports and that also showed rapid modulation of CH4 abundance.[8] argued that absorption features assigned to Mars 12CH4 by [1] might instead be weak lines of terrestrial 13CH4. If not properly removed, terrestrial 13CH4 signatures would appear on the blue wing of terrestrial 12CH4 even when Mars is red-shifted - but they do not (Fig. S6 of [1]), demonstrating that terrestrial signatures were correctly removed. [9] demonstrated that including the dependence of δ13CH4 with altitude did not affect the residual features, nor did taking δ13CH4 as zero. Were δ13CH4 important, its omission would have overemphasized the depth of 13CH4 terrestrial absorption, introducing emission features in the residual spectra [1]. However, the residual features are seen in absorption, establishing their origin as non-terrestrial - [8] now agrees with this view.We later reported results for multiple organic gases (CH4, CH3OH, H2CO, C2H6, C2H2, C2H4), hydroperoxyl (HO2), three nitriles (N2O, NH3, HCN) and two chlorinated species (HCl, CH3Cl) [9]. Most of these species cannot be detected with current space assets, owing to instrumental limitations (e.g., spectral resolving power). However, the high resolution infrared spectrometers (NOMAD, ACS) on ExoMars 2016 (Trace Gas Orbiter) will begin measurements in late 2016. In solar occultation, TGO sensitivities will far exceed prior capabilities.We published detailed hemispheric maps of H2O and HDO on Mars, inferring the size of a lost early ocean [10]. In 2016, we plan to acquire 3-D spatial maps of HDO and H2O with ALMA, and improved maps of organics with iSHELL/NASA-IRTF.References: [1] Mumma et al. Sci09

  9. Electrical impedance scanning as a new imaging modality in breast cancer detection - a short review of clinical value on breast application, limitations and perspectives

    International Nuclear Information System (INIS)

    Malich, A.; Boehm, T.; Facius, M.; Kleinteich, I.; Fleck, M.; Sauner, D.; Anderson, R.; Kaiser, W.A.

    2003-01-01

    Objective. Cancer cells exhibit altered local dielectric properties compared to normal cells, measurable as different electrical conductance and capacitance using electrical impedance scanning (EIS). Therefore, active biocompatible current is applied to the patient for calculation of both parameters taking into account frequency, voltage and current flow. Subjects and methods. 240 women with 280 sonographically and/or mammographically suspicious findings were examined using EIS. All lesions were histologically proven. A lesion was scored as positive, when a focal increased conductance and/or capacitance was measurable using EIS. The lesion was visible as a bright area in a 256 grey-scale computer output. Due to system limitations patients having a pacemaker or pregnant had to be excluded from the study. Results. 91/113 malignant and 108/167 benign lesions were correctly identified using EIS (80.5% sensitivity, 64.7% specificity). NPV and PPV of 83.1% and 60.7% were observed, respectively. Accuracy was 0.73. A wide range of factors can induce false positive results, although by an experienced observer a number of these findings can be detected such as scars, skin alterations, contact artefacts, air bubbles and naevi, hairs and interfering bone. Based upon visibility on ultrasound (194 lesions visible, 86 not visible) significant differences in the detection rate occurred. Histology-dependent detectability rate varied significantly with lowest rate in CIS-cases (50%). Specificity values varied histology-depending, too; probably depending on the rate of proliferation between 75% (inflammatory lesions) and papillomata (50%). Best detectability was observed in malignant lesions with a size between 20 and 30 mm. Further possible applications will be discussed regarding the currently available literature (lymph nodes, salivary glands, mathematical and animal based models). Conclusion. EIS appears to be a promising new additional technology providing a rather high

  10. Approximating the minimum cycle mean

    Directory of Open Access Journals (Sweden)

    Krishnendu Chatterjee

    2013-07-01

    Full Text Available We consider directed graphs where each edge is labeled with an integer weight and study the fundamental algorithmic question of computing the value of a cycle with minimum mean weight. Our contributions are twofold: (1 First we show that the algorithmic question is reducible in O(n^2 time to the problem of a logarithmic number of min-plus matrix multiplications of n-by-n matrices, where n is the number of vertices of the graph. (2 Second, when the weights are nonnegative, we present the first (1 + ε-approximation algorithm for the problem and the running time of our algorithm is ilde(O(n^ω log^3(nW/ε / ε, where O(n^ω is the time required for the classic n-by-n matrix multiplication and W is the maximum value of the weights.

  11. Youth minimum wages and youth employment

    NARCIS (Netherlands)

    Marimpi, Maria; Koning, Pierre

    2018-01-01

    This paper performs a cross-country level analysis on the impact of the level of specific youth minimum wages on the labor market performance of young individuals. We use information on the use and level of youth minimum wages, as compared to the level of adult minimum wages as well as to the median

  12. Do Some Workers Have Minimum Wage Careers?

    Science.gov (United States)

    Carrington, William J.; Fallick, Bruce C.

    2001-01-01

    Most workers who begin their careers in minimum-wage jobs eventually gain more experience and move on to higher paying jobs. However, more than 8% of workers spend at least half of their first 10 working years in minimum wage jobs. Those more likely to have minimum wage careers are less educated, minorities, women with young children, and those…

  13. Does the Minimum Wage Affect Welfare Caseloads?

    Science.gov (United States)

    Page, Marianne E.; Spetz, Joanne; Millar, Jane

    2005-01-01

    Although minimum wages are advocated as a policy that will help the poor, few studies have examined their effect on poor families. This paper uses variation in minimum wages across states and over time to estimate the impact of minimum wage legislation on welfare caseloads. We find that the elasticity of the welfare caseload with respect to the…

  14. Minimum income protection in the Netherlands

    NARCIS (Netherlands)

    van Peijpe, T.

    2009-01-01

    This article offers an overview of the Dutch legal system of minimum income protection through collective bargaining, social security, and statutory minimum wages. In addition to collective agreements, the Dutch statutory minimum wage offers income protection to a small number of workers. Its

  15. The effects of oxygen on process rates and gene expression of anammox and denitrification in the Eastern South Pacific oxygen minimum zone

    DEFF Research Database (Denmark)

    Dalsgaard, Tage; Stewart, Frank; De Brabandere, Loreto

    Oxygen concentrations were consistently below our detection limit of 90 nM for a distance of > 2000 km in the oxygen minimum zone (OMZ) along the coasts of Chile and Peru. In most cases, anammox and denitrification were only detected when in situ oxygen concentrations were below detection...... differently to oxygen. When normalized to a housekeeping gene (rpoB), the expression of 4 out of 9 N-cycle-genes changed with increasing oxygen concentration: The expression of ammonium monooxygenase (amoC) was stimulated, whereas expression of nitrite reductase (nirS), nitric oxide reductase (nor...

  16. Natural activity in Hudson River estuary samples and their influence on the detection limits for gamma emitting radionuclides using NaI gamma spectrometry

    International Nuclear Information System (INIS)

    Wrenn, M.E.; Jinks, S.M.; Hairr, L.M.; Paschoa, A.S.; Lentsch, J.W.

    1972-01-01

    Sources of natural radioactivity in Hudson River Estuary are described. The technique of analysis for gamma spectrometry of environmental samples is presented and its pros and cons discussed. The distribution of natural radioactivity in water, biota and sediment was reported as well as the role played by the vertical distribution of cesium-137 in sediments as an indicator of the rate of sedimentation. The effect of the presence of natural radionuclides on the detection limits of man-made nuclides in the Hudson River environment is thoroughly examined. The results obtained with a 4-in. sodium iodide well crystal housed in a low background mercury shielding compare favorably with a more sophisticated Ge(Li) system which uses anticoincidence, as far as the analysis of environmental samples is concerned. (U.S.)

  17. Insight From the Statistics of Nothing: Estimating Limits of Change Detection Using Inferred No-Change Areas in DEM Difference Maps and Application to Landslide Hazard Studies

    Science.gov (United States)

    Haneberg, W. C.

    2017-12-01

    Remote characterization of new landslides or areas of ongoing movement using differences in high resolution digital elevation models (DEMs) created through time, for example before and after major rains or earthquakes, is an attractive proposition. In the case of large catastrophic landslides, changes may be apparent enough that simple subtraction suffices. In other cases, statistical noise can obscure landslide signatures and place practical limits on detection. In ideal cases on land, GPS surveys of representative areas at the time of DEM creation can quantify the inherent errors. In less-than-ideal terrestrial cases and virtually all submarine cases, it may be impractical or impossible to independently estimate the DEM errors. Examining DEM difference statistics for areas reasonably inferred to have no change, however, can provide insight into the limits of detectability. Data from inferred no-change areas of airborne LiDAR DEM difference maps of the 2014 Oso, Washington landslide and landslide-prone colluvium slopes along the Ohio River valley in northern Kentucky, show that DEM difference maps can have non-zero mean and slope dependent error components consistent with published studies of DEM errors. Statistical thresholds derived from DEM difference error and slope data can help to distinguish between DEM differences that are likely real—and which may indicate landsliding—from those that are likely spurious or irrelevant. This presentation describes and compares two different approaches, one based upon a heuristic assumption about the proportion of the study area likely covered by new landslides and another based upon the amount of change necessary to ensure difference at a specified level of probability.

  18. Improved limits and portability over currently employed cadmium monitoring systems through preconcentration for detection by way of micro-/nanofluidic mechanisms

    Science.gov (United States)

    Wach, Paul

    concentrate Cd at an initial concentration of 0.5 mol/m3, which is nearly half the limit of commercially available technology. Additionally, this preconcentration mechanism was demonstrated to potentially advance its capabilities by attaching channels in series or parallel to further preconcentrate for improved detection. Finally, measurement of extremely low concentrations of Cd is possible due to differences seen in the concentration distribution profiles once steady-state is reached.

  19. Solid phase extraction of large volume of water and beverage samples to improve detection limits for GC-MS analysis of bisphenol A and four other bisphenols.

    Science.gov (United States)

    Cao, Xu-Liang; Popovic, Svetlana

    2018-01-01

    Solid phase extraction (SPE) of large volumes of water and beverage products was investigated for the GC-MS analysis of bisphenol A (BPA), bisphenol AF (BPAF), bisphenol F (BPF), bisphenol E (BPE), and bisphenol B (BPB). While absolute recoveries of the method were improved for water and some beverage products (e.g. diet cola, iced tea), breakthrough may also have occurred during SPE of 200 mL of other beverages (e.g. BPF in cola). Improvements in method detection limits were observed with the analysis of large sample volumes for all bisphenols at ppt (pg/g) to sub-ppt levels. This improvement was found to be proportional to sample volumes for water and beverage products with less interferences and noise levels around the analytes. Matrix effects and interferences were observed during SPE of larger volumes (100 and 200 mL) of the beverage products, and affected the accurate analysis of BPF. This improved method was used to analyse bisphenols in various beverage samples, and only BPA was detected, with levels ranging from 0.022 to 0.030 ng/g for products in PET bottles, and 0.085 to 0.32 ng/g for products in cans.

  20. Comparison of TXRF detection limits for low Z elements in different beam geometries at the PTB monochromator beamline for undulator radiation at Bessy II

    International Nuclear Information System (INIS)

    Beckhoff, B.; Ulm, G.; Pepponi, G.; Streli, C.; Wobrauschek, P.; Fabry, L.; Pahlke, S.

    2000-01-01

    A set of initial TXRF experiments were conducted at the PTB plane grating monochromator beamline for undulator radiation at the electron storage ring BESSY II allowing for exciting energies between 0.1 keV and 1.9 keV. Here, the lower limits of detection of TXRF analysis investigated for some low Z elements such as C, N, 0, Al, Mg and Na in two different detection geometries for various excitation modes. Compared to ordinary XRF geometries involving large incident angles, the TXRF variant offers also at low excitation energies drastically reduced background contributions due to the small penetration depth caused by the total reflection of the incident beam at the polished surface of a flat specimen carrier such as a silicon wafer. For the sake of an application-oriented TXRF approach, droplet samples on Si wafer surfaces were prepared by Wacker Siltronic and investigated in the TXRF irradiation chamber of the Atominstitut offering a semiconductor detector with a thin entrance window that was only 300 nm thick. (author)

  1. Restriction Cascade Exponential Amplification (RCEA) assay with an attomolar detection limit: a novel, highly specific, isothermal alternative to qPCR.

    Science.gov (United States)

    Ghindilis, Andrey L; Smith, Maria W; Simon, Holly M; Seoudi, Ihab A; Yazvenko, Nina S; Murray, Iain A; Fu, Xiaoqing; Smith, Kenneth; Jen-Jacobson, Linda; Xu, Shuang-Yong

    2015-01-13

    An alternative to qPCR was developed for nucleic acid assays, involving signal rather than target amplification. The new technology, Restriction Cascade Exponential Amplification (RCEA), relies on specific cleavage of probe-target hybrids by restriction endonucleases (REase). Two mutant REases for amplification (Ramp), S17C BamHI and K249C EcoRI, were conjugated to oligonucleotides, and immobilized on a solid surface. The signal generation was based on: (i) hybridization of a target DNA to a Ramp-oligonucleotide probe conjugate, followed by (ii) specific cleavage of the probe-target hybrid using a non-immobilized recognition REase. The amount of Ramp released into solution upon cleavage was proportionate to the DNA target amount. Signal amplification was achieved through catalysis, by the free Ramp, of a restriction cascade containing additional oligonucleotide-conjugated Ramp and horseradish peroxidase (HRP). Colorimetric quantification of free HRP indicated that the RCEA achieved a detection limit of 10 aM (10(-17) M) target concentration, or approximately 200 molecules, comparable to the sensitivity of qPCR-based assays. The RCEA assay had high specificity, it was insensitive to non-specific binding, and detected target sequences in the presence of foreign DNA. RCEA is an inexpensive isothermal assay that allows coupling of the restriction cascade signal amplification with any DNA target of interest.

  2. Quantitative method for the detection and localization of quantum-limited events from radionuclides in cells and tissue sections by computer-enhanced video microscopy

    International Nuclear Information System (INIS)

    Pressman, N.J.; Frost, J.K.; Gupta, P.K.; Showers, R.L.; Gill, G.W.; Cook, D.L.; Frost, J.K. Jr.; Traub, R.K.

    1987-01-01

    Cellular dynamics often involve extremely low concentrations of biologically active substances, which can be radiolabeled and detected, localized and quantitated by autoradiography. The latter may require exposures from a few days to many months. The objective of this research was to demonstrate the feasibility of reducing this long period of data collection by one to two orders of magnitude, while maintaining or improving the spatial resolution and localization in tissues and the quantitative characteristics inherent in autoradiography. A mathematical model describing the complete system was generated using energy partition calculations to estimate photon production via scintillant per H3 beta particle emission and to estimate the subsequent photon capture based upon imaging system parameters and microscope geometry. Calculations showed that, typically, a single tritium beta particle produces a maximum of 5.8 X 10(3) photons. A photon-limited camera and microscope imaging system were selected and optimized in conjunction with a specially developed physical scintillation model. Results showed that the number of detected photoevents increases monotonically with both signal integration time and, independently, with the concentration of the radionuclide. Consequently, this work demonstrates that video microscopy imaging methods can spatially and temporally quantify very low concentrations of radiolabeled substances and can reduce data acquisition times

  3. Minimum wage development in the Russian Federation

    OpenAIRE

    Bolsheva, Anna

    2012-01-01

    The aim of this paper is to analyze the effectiveness of the minimum wage policy at the national level in Russia and its impact on living standards in the country. The analysis showed that the national minimum wage in Russia does not serve its original purpose of protecting the lowest wage earners and has no substantial effect on poverty reduction. The national subsistence minimum is too low and cannot be considered an adequate criterion for the setting of the minimum wage. The minimum wage d...

  4. Using an aqueous two-phase polymer-salt system to rapidly concentrate viruses for improving the detection limit of the lateral-flow immunoassay.

    Science.gov (United States)

    Jue, Erik; Yamanishi, Cameron D; Chiu, Ricky Y T; Wu, Benjamin M; Kamei, Daniel T

    2014-12-01

    The development of point-of-need (PON) diagnostics for viruses has the potential to prevent pandemics and protects against biological warfare threats. Here we discuss the approach of using aqueous two-phase systems (ATPSs) to concentrate biomolecules prior to the lateral-flow immunoassay (LFA) for improved viral detection. In this paper, we developed a rapid PON detection assay as an extension to our previous proof-of-concept studies which used a micellar ATPS. We present our investigation of a more rapid polymer-salt ATPS that can drastically improve the assay time, and show that the phase containing the concentrated biomolecule can be extracted prior to macroscopic phase separation equilibrium without affecting the measured biomolecule concentration in that phase. We could therefore significantly decrease the time of the diagnostic assay with an early extraction time of just 30 min. Using this rapid ATPS, the model virus bacteriophage M13 was concentrated between approximately 2 and 10-fold by altering the volume ratio between the two phases. As the extracted virus-rich phase contained a high salt concentration which destabilized the colloidal gold indicator used in LFA, we decorated the gold nanoprobes with polyethylene glycol (PEG) to provide steric stabilization, and used these nanoprobes to demonstrate a 10-fold improvement in the LFA detection limit. Lastly, a MATLAB script was used to quantify the LFA results with and without the pre-concentration step. This approach of combining a rapid ATPS with LFA has great potential for PON applications, especially as greater concentration-fold improvements can be achieved by further varying the volume ratio. Biotechnol. Bioeng. 2014;111: 2499-2507. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  5. Comparison of false-negative rates and limits of detection following macrofoam-swab sampling of Bacillus anthracis surrogates via Rapid Viability PCR and plate culture.

    Science.gov (United States)

    Hutchison, J R; Piepel, G F; Amidan, B G; Hess, B M; Sydor, M A; Deatherage Kaiser, B L

    2018-05-01

    We evaluated the effects of Bacillus anthracis surrogates, low surface concentrations, surface materials and assay methods on false-negative rate (FNR) and limit of detection (LOD 95 ) for recovering Bacillus spores using a macrofoam-swab sampling procedure. Bacillus anthracis Sterne or Bacillus atrophaeus Nakamura spores were deposited over a range of low target concentrations (2-500 per coupon) onto glass, stainless steel, vinyl tile and plastic. Samples were assayed using a modified Rapid Viability-PCR (mRV-PCR) method and the traditional plate culture method to obtain FNR and LOD 95 results. Mean FNRs tended to be lower for mRV-PCR compared to culturing, and increased as spore concentration decreased for all surface materials. Surface material, but not B. anthracis surrogate, influenced FNRs with the mRV-PCR method. The mRV-PCR LOD 95 was lowest for glass and highest for vinyl tile. LOD 95 values overall were lower for mRV-PCR than for the culture method. This study adds to the limited data on FNR and LOD 95 for mRV-PCR and culturing methods with low concentrations of B. anthracis sampled from various surface materials by the CDC macrofoam-swab method. These are key inputs for planning characterization and clearance studies for low contamination levels of B. anthracis. © 2018 The Society for Applied Microbiology.

  6. Good news for conservation: mitochondrial and microsatellite DNA data detect limited genetic signatures of inter-basin fish transfer in Thymallus thymallus (Salmonidae from the Upper Drava River

    Directory of Open Access Journals (Sweden)

    Meraner A.

    2013-06-01

    Full Text Available In the last few decades, numerous populations of European grayling, Thymallus thymallus, have been suffering from stocking-induced genetic admixture of foreign strains into wild populations. Concordantly, genetic introgression was also reportedfor grayling stocks inhabiting the Upper Drava River, but all published genetic data based on specimens caught at least a decade ago, when stocking load was strong. Here, we applied mitochondrial control region sequencing and nuclear microsatellite genotyping to Upper Drava grayling fry collections and reference samples to update patterns and extent of human-mediated introgression. In contrast to previous data, we highlighted an almost genetic integrity of Drava grayling, evidencing limited genetic signatures of trans-basin stocking for grayling of Northern Alpine Danubian origin. Recent hybridisation was detected only twice among sixty-nine samples, while several cases of later-generation hybrids were disclosed by linking mitochondrial sequence to nuclear genetic data. The observed past, but very limited recent genetic introgression in grayling from Upper Drava seems to reflect shifting stocking trends, changing from massive introduction of trans-basin fish to more conservation-oriented strategies during the last 27 years. In a conservation context, we encourage pursuing the use of local wild grayling for supportive- and captive-breeding, but underline the need for genetic approaches in brood-stock selection programs. Finally, our integrated results from sibship reconstruction validate our strictly fry-based sampling scheme, thus offering a reasonable alternative also for other rheophilic fish species with similar life-history characteristics.

  7. Estimation by limiting dilution analysis of human IL 2-secreting T cells: detection of IL 2 produced by single lymphokine-secreting T cells

    International Nuclear Information System (INIS)

    Vie, H.; Miller, R.A.

    1986-01-01

    We present here a culture method for the estimation, in human blood, of the number of lymphocytes that can respond to mitogen by producing interleukin 2 (IL 2). T cells are cultured at limiting dilutions with PHA or Con A in the presence of Epstein Barr virus-transformed human lymphoblastoid cells (EB-LCL), and supernatants are tested 3 days later for IL 2 content by a cell proliferation assay. The distribution of negative wells follows the expected Poisson single-hit relationship, suggesting that the assay is sensitive to single cells of a single limiting cell type. On average, 16.3% of peripheral blood mononuclear cells can produce IL 2 in such clonal cultures (mean of 12 determinations; SD = 5.6%). Surprisingly, irradiation (up to 2000 rad) of the titrated responder cell population diminishes the estimated frequencies by less than 50%. The ability to detect IL 2 levels in cultures containing only a single, nonproliferating T lymphocyte allows us to estimate the amount of IL 2 generated by an individual effector cell during a 3-day culture interval after mitogen stimulation. The average responding, irradiated T cell generates 0.92 pg of IL 2 (median) within 3 days. The method presented provides a straightforward way to provide independent estimates of responding cell number and of lymphokine production per cell in a variety of clinical situations

  8. Statistical analysis of water-quality data containing multiple detection limits II: S-language software for nonparametric distribution modeling and hypothesis testing

    Science.gov (United States)

    Lee, L.; Helsel, D.

    2007-01-01

    Analysis of low concentrations of trace contaminants in environmental media often results in left-censored data that are below some limit of analytical precision. Interpretation of values becomes complicated when there are multiple detection limits in the data-perhaps as a result of changing analytical precision over time. Parametric and semi-parametric methods, such as maximum likelihood estimation and robust regression on order statistics, can be employed to model distributions of multiply censored data and provide estimates of summary statistics. However, these methods are based on assumptions about the underlying distribution of data. Nonparametric methods provide an alternative that does not require such assumptions. A standard nonparametric method for estimating summary statistics of multiply-censored data is the Kaplan-Meier (K-M) method. This method has seen widespread usage in the medical sciences within a general framework termed "survival analysis" where it is employed with right-censored time-to-failure data. However, K-M methods are equally valid for the left-censored data common in the geosciences. Our S-language software provides an analytical framework based on K-M methods that is tailored to the needs of the earth and environmental sciences community. This includes routines for the generation of empirical cumulative distribution functions, prediction or exceedance probabilities, and related confidence limits computation. Additionally, our software contains K-M-based routines for nonparametric hypothesis testing among an unlimited number of grouping variables. A primary characteristic of K-M methods is that they do not perform extrapolation and interpolation. Thus, these routines cannot be used to model statistics beyond the observed data range or when linear interpolation is desired. For such applications, the aforementioned parametric and semi-parametric methods must be used.

  9. Thermal background noise limitations

    Science.gov (United States)

    Gulkis, S.

    1982-01-01

    Modern detection systems are increasingly limited in sensitivity by the background thermal photons which enter the receiving system. Expressions for the fluctuations of detected thermal radiation are derived. Incoherent and heterodyne detection processes are considered. References to the subject of photon detection statistics are given.

  10. The impact of the minimum wage on health.

    Science.gov (United States)

    Andreyeva, Elena; Ukert, Benjamin

    2018-03-07

    This study evaluates the effect of minimum wage on risky health behaviors, healthcare access, and self-reported health. We use data from the 1993-2015 Behavioral Risk Factor Surveillance System, and employ a difference-in-differences strategy that utilizes time variation in new minimum wage laws across U.S. states. Results suggest that the minimum wage increases the probability of being obese and decreases daily fruit and vegetable intake, but also decreases days with functional limitations while having no impact on healthcare access. Subsample analyses reveal that the increase in weight and decrease in fruit and vegetable intake are driven by the older population, married, and whites. The improvement in self-reported health is especially strong among non-whites, females, and married.

  11. Minimum Additive Waste Stabilization (MAWS)

    International Nuclear Information System (INIS)

    1994-02-01

    In the Minimum Additive Waste Stabilization(MAWS) concept, actual waste streams are utilized as additive resources for vitrification, which may contain the basic components (glass formers and fluxes) for making a suitable glass or glassy slag. If too much glass former is present, then the melt viscosity or temperature will be too high for processing; while if there is too much flux, then the durability may suffer. Therefore, there are optimum combinations of these two important classes of constituents depending on the criteria required. The challenge is to combine these resources in such a way that minimizes the use of non-waste additives yet yields a processable and durable final waste form for disposal. The benefit to this approach is that the volume of the final waste form is minimized (waste loading maximized) since little or no additives are used and vitrification itself results in volume reduction through evaporation of water, combustion of organics, and compaction of the solids into a non-porous glass. This implies a significant reduction in disposal costs due to volume reduction alone, and minimizes future risks/costs due to the long term durability and leach resistance of glass. This is accomplished by using integrated systems that are both cost-effective and produce an environmentally sound waste form for disposal. individual component technologies may include: vitrification; thermal destruction; soil washing; gas scrubbing/filtration; and, ion-exchange wastewater treatment. The particular combination of technologies will depend on the waste streams to be treated. At the heart of MAWS is vitrification technology, which incorporates all primary and secondary waste streams into a final, long-term, stabilized glass wasteform. The integrated technology approach, and view of waste streams as resources, is innovative yet practical to cost effectively treat a broad range of DOE mixed and low-level wastes

  12. Surface flaw detection by means of infrared radiometer. Part 3. ; Detection limit influenced by an environment temperature. Sekigai hoshakei ni yoru hyomen kekkan no kenshutsu. 3. ; Shuhen ondo ni yoru kenshutsu genkai no eikyo

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, U; Kaminaga, F [Ibaraki University, Ibaraki (Japan). Faculty of Engineering; Ishii, T [Ibaraki University, Ibaraki (Japan); Eto, M; Ooka, N; Kanaya, K; Eto, Y [Japan Atomic Energy Research Institute, Ibaraki (Japan); Kurokawa, T [Nippon Denki Sanei Ltd. Co., Tokyo (Japan)

    1990-12-20

    Measuring a radiation energy distribution around surface flaw by means of a infrared rediometer can detect fine flaw on the surface. The characteristics were examined using a light quantum type radiation thermometer consisted of Hg-Cd-Te as a sensor. A surrounding wall consisted of a black body wall was installed between the sensor and test piece, and by thus maintaining the surrounding wall temperature constant, reflection energy from the test piece surface was maintained constant for stabilized measurement. The measurement values are the sum of energies from emission and reflection, or the so-called radiosity values. To avoid effects from the reflection to reduce variance in the emissivity, it is necessary to keep the surrounding wall temperatures lower by more than 20 {degree}C than the test piece radiation temperatures. Emissivity can be calculated from the rediositivity (sum of the radiation and the reflection), the surrounding wall temperatures, and the test piece radiation temperatures. If the surface is rough, variance in the measurements increases. The larger the difference in the test piece and surrounding wall temperatures, the thermo image of the defects on the test piece surface becomes more distinctive, thus the detection limit can be enhanced. 7 refs., 13 figs.

  13. Use of magnetic resonance imaging to detect neoplastic meningitis: Limited use in leukemia and lymphoma but convincing results in solid tumors

    International Nuclear Information System (INIS)

    Pauls, Sandra; Fischer, Ann-Cathrin; Brambs, Hans-Jürgen; Fetscher, Sebastian; Höche, Wolfram; Bommer, Martin

    2012-01-01

    Background: An early diagnosis of meningitis is important to improve patients’ survival. Data about a direct comparison of cerebrospinal fluid cytology (CSF-cytology) and MRI are very limited. Therefore, the aim of this study was to compare these two diagnostic modalities in diagnosing meningitis in patients with hematopoietic and solid malignancies. Methods: In 68 patients suspicious for neoplastic meningitis, cytology and MRI (1.5 T) was performed. The meningeal, pial or intraparenchymal hyperintense signal or contrast enhancement was correlated to the final CNS diagnosis and to cytology. Results: 44 patients (64.7%) had neoplastic meningitis, 21 patients (30.9%) had non-neoplastic meningitis. The sensitivity to diagnose meningeal disease was 49.2% for MRI and 95.4% for cytology (p < 0.001). In patients with neoplastic meningitis, sensitivity was 45.5% for MRI and 93.2% for cytology (p < 0.001). In patients with infectious meningitis, sensitivity was 57.1% for MRI and 100% for cytology (p = 0.0013). In patients with solid tumors, the sensitivity was 84.6% for both diagnostic methods. The sensitivity for MRI was low in patients with leukemia (20.0%) and lymphoma (37.5%). The positive predictive value (PPV) for MRI to differentiate infectious from neoplastic meningitis was high in patients with infectious meningitis (75.0%), in patients with lymphoma (83.3%), and in patients with solid tumors (72.7%). Ppv was low in patients with leukemia (33.3%). Conclusion: Diagnostic value of MRI for diagnosing meningitis is especially limited in patients with hematopoietic malignancies. MRI better detected leptomeningeal involvement caused by solid tumors than by leukemia or lymphoma. The ppv to specify neoplastic meningitis depends on tumor subtype.

  14. Electronic Nose Testing Procedure for the Definition of Minimum Performance Requirements for Environmental Odor Monitoring

    Directory of Open Access Journals (Sweden)

    Lidia Eusebio

    2016-09-01

    Full Text Available Despite initial enthusiasm towards electronic noses and their possible application in different fields, and quite a lot of promising results, several criticalities emerge from most published research studies, and, as a matter of fact, the diffusion of electronic noses in real-life applications is still very limited. In general, a first step towards large-scale-diffusion of an analysis method, is standardization. The aim of this paper is describing the experimental procedure adopted in order to evaluate electronic nose performances, with the final purpose of establishing minimum performance requirements, which is considered to be a first crucial step towards standardization of the specific case of electronic nose application for environmental odor monitoring at receptors. Based on the experimental results of the performance testing of a commercialized electronic nose type with respect to three criteria (i.e., response invariability to variable atmospheric conditions, instrumental detection limit, and odor classification accuracy, it was possible to hypothesize a logic that could be adopted for the definition of minimum performance requirements, according to the idea that these are technologically achievable.

  15. Evaluation of the Charm maximum residue limit β-lactam and tetracycline test for the detection of antibiotics in ewe and goat milk.

    Science.gov (United States)

    Beltrán, M C; Romero, T; Althaus, R L; Molina, M P

    2013-05-01

    The Charm maximum residue limit β-lactam and tetracycline test (Charm MRL BLTET; Charm Sciences Inc., Lawrence, MA) is an immunoreceptor assay utilizing Rapid One-Step Assay lateral flow technology that detects β-lactam or tetracycline drugs in raw commingled cow milk at or below European Union maximum residue levels (EU-MRL). The Charm MRL BLTET test procedure was recently modified (dilution in buffer and longer incubation) by the manufacturers to be used with raw ewe and goat milk. To assess the Charm MRL BLTET test for the detection of β-lactams and tetracyclines in milk of small ruminants, an evaluation study was performed at Instituto de Ciencia y Tecnologia Animal of Universitat Politècnica de València (Spain). The test specificity and detection capability (CCβ) were studied following Commission Decision 2002/657/EC. Specificity results obtained in this study were optimal for individual milk free of antimicrobials from ewes (99.2% for β-lactams and 100% for tetracyclines) and goats (97.9% for β-lactams and 100% for tetracyclines) along the entire lactation period regardless of whether the results were visually or instrumentally interpreted. Moreover, no positive results were obtained when a relatively high concentration of different substances belonging to antimicrobial families other than β-lactams and tetracyclines were present in ewe and goat milk. For both types of milk, the CCβ calculated was lower or equal to EU-MRL for amoxicillin (4 µg/kg), ampicillin (4 µg/kg), benzylpenicillin (≤ 2 µg/kg), dicloxacillin (30 µg/kg), oxacillin (30 µg/kg), cefacetrile (≤ 63 µg/kg), cefalonium (≤ 10 µg/kg), cefapirin (≤ 30 µg/kg), desacetylcefapirin (≤ 30 µg/kg), cefazolin (≤ 25 µg/kg), cefoperazone (≤ 25 µg/kg), cefquinome (20 µg/kg), ceftiofur (≤ 50 µg/kg), desfuroylceftiofur (≤ 50µg/kg), and cephalexin (≤ 50 µg/kg). However, this test could neither detect cloxacillin nor nafcillin at or below EU-MRL (CCβ >30 µg/kg). The

  16. Minimum emittance of three-bend achromats

    International Nuclear Information System (INIS)

    Li Xiaoyu; Xu Gang

    2012-01-01

    The calculation of the minimum emittance of three-bend achromats (TBAs) made by Mathematical software can ignore the actual magnets lattice in the matching condition of dispersion function in phase space. The minimum scaling factors of two kinds of widely used TBA lattices are obtained. Then the relationship between the lengths and the radii of the three dipoles in TBA is obtained and so is the minimum scaling factor, when the TBA lattice achieves its minimum emittance. The procedure of analysis and the results can be widely used in achromats lattices, because the calculation is not restricted by the actual lattice. (authors)

  17. A Pareto-Improving Minimum Wage

    OpenAIRE

    Eliav Danziger; Leif Danziger

    2014-01-01

    This paper shows that a graduated minimum wage, in contrast to a constant minimum wage, can provide a strict Pareto improvement over what can be achieved with an optimal income tax. The reason is that a graduated minimum wage requires high-productivity workers to work more to earn the same income as low-productivity workers, which makes it more difficult for the former to mimic the latter. In effect, a graduated minimum wage allows the low-productivity workers to benefit from second-degree pr...

  18. The minimum wage in the Czech enterprises

    OpenAIRE

    Eva Lajtkepová

    2010-01-01

    Although the statutory minimum wage is not a new category, in the Czech Republic we encounter the definition and regulation of a minimum wage for the first time in the 1990 amendment to Act No. 65/1965 Coll., the Labour Code. The specific amount of the minimum wage and the conditions of its operation were then subsequently determined by government regulation in February 1991. Since that time, the value of minimum wage has been adjusted fifteenth times (the last increase was in January 2007). ...

  19. Minimum detectable differences for cane yield, sucrose content and ...

    African Journals Online (AJOL)

    guide during the selection process. Genotypes with ... defined experimental variables such as locations, replica- tions and ... is high and well distributed and soils are deep while the ... variable and sometimes shallow and eldana predation is.

  20. Simultaneous estimation of vitamin K1 and heparin with low limit of detection using cascaded channels fiber optic surface plasmon resonance.

    Science.gov (United States)

    Tabassum, Rana; Gupta, Banshi D

    2016-12-15

    We report an approach for the simultaneous estimation of vitamin K1 (VK1) and heparin via cascaded channel multianalyte sensing probe employing fiber optic surface plasmon resonance technique. Cladding from two well separated portions of the fiber is removed and are respectively coated with thin films of silver (channel-1) and copper (channel-2). The nanohybrid of multiwalled carbon nanotube in chitosan is fabricated over silver layer for the sensing of VK1 whereas core shell nanostructure of polybrene@ZnO is coated over copper layer for the sensing of heparin. Spectral interrogation method is used for the characterization of the sensor. Analyte selectivity of both the channels is performed by carrying out experiments using independent solutions of VK1 and heparin. Experiments performed on the solution of the mixture of VK1 and heparin show red shifts in both the channels on changing the concentration of both the analytes in the mixture. The operating range of both VK1 and heparin is from 0 to 10(-3)g/l. The limit of detection of the sensor is 2.66×10(-4)µg/l and 2.88×10(-4)µg/l for VK1 and heparin respectively which are lower than the reported ones. The additional advantages of the present sensor are low cost, possibility of online monitoring and remote sensing. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Polyethylene imine/graphene oxide layer-by-layer surface functionalization for significantly improved limit of detection and binding kinetics of immunoassays on acrylate surfaces.

    Science.gov (United States)

    Miyazaki, Celina M; Mishra, Rohit; Kinahan, David J; Ferreira, Marystela; Ducrée, Jens

    2017-10-01

    Antibody immobilization on polymeric substrates is a key manufacturing step for microfluidic devices that implement sample-to-answer automation of immunoassays. In this work, a simple and versatile method to bio-functionalize poly(methylmethacrylate) (PMMA), a common material of such "Lab-on-a-Chip" systems, is proposed; using the Layer-by-Layer (LbL) technique, we assemble nanostructured thin films of poly(ethylene imine) (PEI) and graphene oxide (GO). The wettability of PMMA surfaces was significantly augmented by the surface treatment with (PEI/GO) 5 film, with an 81% reduction of the contact angle, while the surface roughness increased by 600%, thus clearly enhancing wettability and antibody binding capacity. When applied to enzyme-linked immunosorbent assays (ELISAs), the limit of detection of PMMA surface was notably improved from 340pgmL -1 on commercial grade polystyrene (PS) and 230pgmL -1 on plain PMMA surfaces to 130pgmL -1 on (PEI/GO) 5 treated PMMA. Furthermore, the accelerated antibody adsorption kinetics on the LbL films of GO allowed to substantially shorten incubation times, e.g. for anti-rat IgG adsorption from 2h down to 15min on conventional and treated surfaces, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Background radiation accumulation and lower limit of detection in thermoluminescent beta-gamma dosimeters used by the centralized external dosimetry system

    International Nuclear Information System (INIS)

    Sonder, E.; Ahmed, A.B.

    1991-12-01

    A value for ''average background radiation'' of 0.75 mR/week has been determined from a total of 1680 thermoluminescent dosimeters (TLD's) exposed in 70 houses for periods up to one year. The distribution of results indicates a rather large variation among houses, with a few locations exhibiting backgrounds double the general average. Some discrepancies in the short-term background accumulation of TLD's have been explained as being due to light leakage through the dosimeter cases. In addition the lower limit of detection (L D ) for deep and shallow dose equivalents has been determined for these dosimeters. The L D for occupational exposure depends strongly on the time a dosimeter is exposed to background radiation in the field. The L D can vary from a low of 2.4 mrem for high energy gamma rays when the background accumulation period is less than a few weeks to values as high as 66 mrem for uranium beta particles when background has been allowed to accumulate for more than 21 weeks

  3. Determination of the detection limit and decision threshold for ionizing radiation measurements. Part 2: Fundamentals and application to counting measurements with the influence of sample treatment

    International Nuclear Information System (INIS)

    2000-01-01

    This part of ISO 11929 addresses the field of ionizing radiation measurements in which events (in particular pulses) on samples are counted after treating them (e.g. aliquotation, solution, enrichment, separation). It considers, besides the random character of radioactive decay and of pulse counting, all other influences arising from sample treatment, (e.g. weighing, enrichment, calibration or the instability of the test setup). ISO 11929 consists of the following parts, under the general title Determination of the detection limit and decision threshold for ionizing radiation measurements: Part 1: Fundamentals and application to counting measurements without the influence of sample treatment; Part 2: Fundamentals and application to counting measurements with the influence of sample treatment; Part 3: Fundamentals and application to counting measurements by high resolution gamma spectrometry, without the influence of sample treatment; Part 4: Fundamentals and application to measurements by use of linear scale analogue ratemeters, without the influence of sample treatment. This part of ISO 11929 was prepared in parallel with other International Standards prepared by WG 2 (now WG 17): ISO 11932:1996, Activity measurements of solid materials considered for recycling, re-use or disposal as non radioactive waste, and ISO 11929-1, ISO 11929-3 and ISO 11929-4 and is, consequently, complementary to these documents

  4. Minimum Benefits for HIV/AIDS in South African Medical Schemes ...

    African Journals Online (AJOL)

    ... to the Minister of Health in respect of the extent of prescribed minimum benefits for HIV/AIDS. Medical schemes are required to provide the PMBs to their members without limits or co-payments. Keywords: Medical schemes; HIV; AIDS; benefits; prescribed minimum benefits. South African Actuarial Journal: 2003 3: 77-112 ...

  5. Stochastic variational approach to minimum uncertainty states

    Energy Technology Data Exchange (ETDEWEB)

    Illuminati, F.; Viola, L. [Dipartimento di Fisica, Padova Univ. (Italy)

    1995-05-21

    We introduce a new variational characterization of Gaussian diffusion processes as minimum uncertainty states. We then define a variational method constrained by kinematics of diffusions and Schroedinger dynamics to seek states of local minimum uncertainty for general non-harmonic potentials. (author)

  6. Zero forcing parameters and minimum rank problems

    NARCIS (Netherlands)

    Barioli, F.; Barrett, W.; Fallat, S.M.; Hall, H.T.; Hogben, L.; Shader, B.L.; Driessche, van den P.; Holst, van der H.

    2010-01-01

    The zero forcing number Z(G), which is the minimum number of vertices in a zero forcing set of a graph G, is used to study the maximum nullity/minimum rank of the family of symmetric matrices described by G. It is shown that for a connected graph of order at least two, no vertex is in every zero

  7. 30 CFR 281.30 - Minimum royalty.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Minimum royalty. 281.30 Section 281.30 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE LEASING OF MINERALS OTHER THAN OIL, GAS, AND SULPHUR IN THE OUTER CONTINENTAL SHELF Financial Considerations § 281.30 Minimum royalty...

  8. New Minimum Wage Research: A Symposium.

    Science.gov (United States)

    Ehrenberg, Ronald G.; And Others

    1992-01-01

    Includes "Introduction" (Ehrenberg); "Effect of the Minimum Wage [MW] on the Fast-Food Industry" (Katz, Krueger); "Using Regional Variation in Wages to Measure Effects of the Federal MW" (Card); "Do MWs Reduce Employment?" (Card); "Employment Effects of Minimum and Subminimum Wages" (Neumark,…

  9. Minimum Wage Effects in the Longer Run

    Science.gov (United States)

    Neumark, David; Nizalova, Olena

    2007-01-01

    Exposure to minimum wages at young ages could lead to adverse longer-run effects via decreased labor market experience and tenure, and diminished education and training, while beneficial longer-run effects could arise if minimum wages increase skill acquisition. Evidence suggests that as individuals reach their late 20s, they earn less the longer…

  10. Leak detection : Principles and practice

    International Nuclear Information System (INIS)

    Rama Rao, V.V.K.

    1981-01-01

    Principles of leak detection are explained and various aspects of leak detection techniques and leak detectors are reviewed. The review covers: units for leaks and leak tightness, classification of leaks, timing of leak testing, designing for ease of leak testing of any job, methods of leak detection, their ranges of application and limitations, leak detectors, response time of leak test, minimum detectable concentration of search gas during leak tests, and validity of leak tests. Helium mass spectrometer type leak detector and technique are described in detail. Recent improvements in leak detectors and techniques, particularly mass spectrometer leak detectors using gases other than helium (e.g. hydrogen, argon) are also covered in the review. (M.G.B.)

  11. The power of reordering for online minimum makespan scheduling

    OpenAIRE

    Englert, Matthias; Özmen, Deniz; Westermann, Matthias

    2014-01-01

    In the classic minimum makespan scheduling problem, we are given an input sequence of jobs with processing times. A scheduling algorithm has to assign the jobs to m parallel machines. The objective is to minimize the makespan, which is the time it takes until all jobs are processed. In this paper, we consider online scheduling algorithms without preemption. However, we do not require that each arriving job has to be assigned immediately to one of the machines. A reordering buffer with limited...

  12. Minimum deterrence and regional security. Section 2. Other regions

    International Nuclear Information System (INIS)

    Azikiwe, A.E.

    1993-01-01

    Compared to European political and security circumstance, minimum deterrence is less an illusion in other regions where weapon free zones already exist. It will continue to be relevant to the security of other regions. Strategic arms limitation should be pursued vigorously in a constructive and pragmatic manner, bearing in mind the need to readjust to new global challenges. The Comprehensive Test Ban Treaty is the linchpin on which the Non-proliferation Treaty rests

  13. Estimating the mean and standard deviation of environmental data with below detection limit observations: Considering highly skewed data and model misspecification.

    Science.gov (United States)

    Shoari, Niloofar; Dubé, Jean-Sébastien; Chenouri, Shoja'eddin

    2015-11-01

    In environmental studies, concentration measurements frequently fall below detection limits of measuring instruments, resulting in left-censored data. Some studies employ parametric methods such as the maximum likelihood estimator (MLE), robust regression on order statistic (rROS), and gamma regression on order statistic (GROS), while others suggest a non-parametric approach, the Kaplan-Meier method (KM). Using examples of real data from a soil characterization study in Montreal, we highlight the need for additional investigations that aim at unifying the existing literature. A number of studies have examined this issue; however, those considering data skewness and model misspecification are rare. These aspects are investigated in this paper through simulations. Among other findings, results show that for low skewed data, the performance of different statistical methods is comparable, regardless of the censoring percentage and sample size. For highly skewed data, the performance of the MLE method under lognormal and Weibull distributions is questionable; particularly, when the sample size is small or censoring percentage is high. In such conditions, MLE under gamma distribution, rROS, GROS, and KM are less sensitive to skewness. Related to model misspecification, MLE based on lognormal and Weibull distributions provides poor estimates when the true distribution of data is misspecified. However, the methods of rROS, GROS, and MLE under gamma distribution are generally robust to model misspecifications regardless of skewness, sample size, and censoring percentage. Since the characteristics of environmental data (e.g., type of distribution and skewness) are unknown a priori, we suggest using MLE based on gamma distribution, rROS and GROS. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Deatherage Kaiser, Brooke L [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Barrett, Christopher A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-31

    The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in. × 2 in.) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm2, where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results will be discussed in a subsequent report.

  15. Recovery Efficiency, False Negative Rate, and Limit of Detection Performance of a Validated Macrofoam-Swab Sampling Method with Low Surface Concentrations of Two Bacillus anthracis Surrogates

    Energy Technology Data Exchange (ETDEWEB)

    Piepel, Gregory F. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hutchison, Janine R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kaiser, Brooke L. D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Amidan, Brett G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sydor, Michael A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Barrett, Christopher A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-16

    The performance of a macrofoam-swab sampling method was evaluated using Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus Nakamura (BG) spores applied at nine low target amounts (2-500 spores) to positive-control plates and test coupons (2 in × 2 in) of four surface materials (glass, stainless steel, vinyl tile, and plastic). Test results from cultured samples were used to evaluate the effects of surrogate, surface concentration, and surface material on recovery efficiency (RE), false negative rate (FNR), and limit of detection. For RE, surrogate and surface material had statistically significant effects, but concentration did not. Mean REs were the lowest for vinyl tile (50.8% with BAS, 40.2% with BG) and the highest for glass (92.8% with BAS, 71.4% with BG). FNR values ranged from 0 to 0.833 for BAS and 0 to 0.806 for BG, with values increasing as concentration decreased in the range tested (0.078 to 19.375 CFU/cm2, where CFU denotes ‘colony forming units’). Surface material also had a statistically significant effect. A FNR-concentration curve was fit for each combination of surrogate and surface material. For both surrogates, the FNR curves tended to be the lowest for glass and highest for vinyl title. The FNR curves for BG tended to be higher than for BAS at lower concentrations, especially for glass. Results using a modified Rapid Viability-Polymerase Chain Reaction (mRV-PCR) analysis method were also obtained. The mRV-PCR results and comparisons to the culture results are discussed in a separate report.

  16. Minimum Energy Requirements in Complex Distillation Arrangements

    Energy Technology Data Exchange (ETDEWEB)

    Halvorsen, Ivar J.

    2001-07-01

    Distillation is the most widely used industrial separation technology and distillation units are responsible for a significant part of the total heat consumption in the world's process industry. In this work we focus on directly (fully thermally) coupled column arrangements for separation of multicomponent mixtures. These systems are also denoted Petlyuk arrangements, where a particular implementation is the dividing wall column. Energy savings in the range of 20-40% have been reported with ternary feed mixtures. In addition to energy savings, such integrated units have also a potential for reduced capital cost, making them extra attractive. However, the industrial use has been limited, and difficulties in design and control have been reported as the main reasons. Minimum energy results have only been available for ternary feed mixtures and sharp product splits. This motivates further research in this area, and this thesis will hopefully give some contributions to better understanding of complex column systems. In the first part we derive the general analytic solution for minimum energy consumption in directly coupled columns for a multicomponent feed and any number of products. To our knowledge, this is a new contribution in the field. The basic assumptions are constant relative volatility, constant pressure and constant molar flows and the derivation is based on Underwood's classical methods. An important conclusion is that the minimum energy consumption in a complex directly integrated multi-product arrangement is the same as for the most difficult split between any pair of the specified products when we consider the performance of a conventional two-product column. We also present the Vmin-diagram, which is a simple graphical tool for visualisation of minimum energy related to feed distribution. The Vmin-diagram provides a simple mean to assess the detailed flow requirements for all parts of a complex directly coupled arrangement. The main purpose in

  17. Minimum Energy Requirements in Complex Distillation Arrangements

    Energy Technology Data Exchange (ETDEWEB)

    Halvorsen, Ivar J

    2001-07-01

    Distillation is the most widely used industrial separation technology and distillation units are responsible for a significant part of the total heat consumption in the world's process industry. In this work we focus on directly (fully thermally) coupled column arrangements for separation of multicomponent mixtures. These systems are also denoted Petlyuk arrangements, where a particular implementation is the dividing wall column. Energy savings in the range of 20-40% have been reported with ternary feed mixtures. In addition to energy savings, such integrated units have also a potential for reduced capital cost, making them extra attractive. However, the industrial use has been limited, and difficulties in design and control have been reported as the main reasons. Minimum energy results have only been available for ternary feed mixtures and sharp product splits. This motivates further research in this area, and this thesis will hopefully give some contributions to better understanding of complex column systems. In the first part we derive the general analytic solution for minimum energy consumption in directly coupled columns for a multicomponent feed and any number of products. To our knowledge, this is a new contribution in the field. The basic assumptions are constant relative volatility, constant pressure and constant molar flows and the derivation is based on Underwood's classical methods. An important conclusion is that the minimum energy consumption in a complex directly integrated multi-product arrangement is the same as for the most difficult split between any pair of the specified products when we consider the performance of a conventional two-product column. We also present the Vmin-diagram, which is a simple graphical tool for visualisation of minimum energy related to feed distribution. The Vmin-diagram provides a simple mean to assess the detailed flow requirements for all parts of a complex directly coupled arrangement. The main purpose in the first

  18. Widespread functional anoxia in the oxygen minimum zone of the Eastern South Pacific

    Science.gov (United States)

    Thamdrup, Bo; Dalsgaard, Tage; Revsbech, Niels Peter

    Oxygen minimum zones (OMZs) as found in the Eastern Pacific and Indian Ocean are biogeochemical hot spots with a disproportionately large role in the marine nitrogen cycle, and they are important components of the highly productive ecosystems in which they occur. Although the oxygen-depleted waters have been known for a century, oxygen levels inside them are not well constrained and the regulation of their anaerobic processes by oxygen is poorly understood. We deployed highly sensitive STOX oxygen sensors with a detection limit of 10 nmol kg-1 in combination with conventional hydrographic oxygen sensors along a cruise track transecting the Eastern South Pacific OMZ from South to North along the coast of Chile and Peru. Oxygen was below the detection limit throughout the ˜200 m thick OMZ core in most casts with STOX sensors. The only exception was an offshore location off Peru where oxygen was 10-50 nmol kg-1 in the core, likely as the result of a transient intrusion. Oxygen was also not detected in the OMZ core in further casts with conventional sensors, which had a detection limit of 90 nmol kg-1 after STOX-based zero calibration. Our measurements tighten the constraints on typical oxygen concentrations in the inner part of the OMZ by at least an order of magnitude relative to previous reports. Nitrite only accumulated when oxygen was depleted below 50 nmol kg-1, which indicates that nitrogen cycling is much more sensitive to oxygen than previously estimated. We argue that extreme oxygen depletion to low nanomalar or even picomolar concentrations is a normal condition in the South Pacific OMZ, and suggest that the OMZ core is in fact functionally anoxic over wide regions for extended periods. Our results further indicate that oxygen dynamics in the low nanomolar range play an important role in OMZ biogeochemistry.

  19. Limit of detection in the presence of instrumental and non-instrumental errors: study of the possible sources of error and application to the analysis of 41 elements at trace levels by inductively coupled plasma-mass spectrometry technique

    International Nuclear Information System (INIS)

    Badocco, Denis; Lavagnini, Irma; Mondin, Andrea; Tapparo, Andrea; Pastore, Paolo

    2015-01-01

    In this paper the detection limit was estimated when signals were affected by two error contributions, namely instrumental errors and operational-non-instrumental errors. The detection limit was theoretically obtained following the hypothesis testing schema implemented with the calibration curve methodology. The experimental calibration design was based on J standards measured I times with non-instrumental errors affecting each standard systematically but randomly among the J levels. A two-component variance regression was performed to determine the calibration curve and to define the detection limit in these conditions. The detection limit values obtained from the calibration at trace levels of 41 elements by ICP-MS resulted larger than those obtainable from a one component variance regression. The role of the reagent impurities on the instrumental errors was ascertained and taken into account. Environmental pollution was studied as source of non-instrumental errors. The environmental pollution role was evaluated by Principal Component Analysis technique (PCA) applied to a series of nine calibrations performed in fourteen months. The influence of the seasonality of the environmental pollution on the detection limit was evidenced for many elements usually present in the urban air particulate. The obtained results clearly indicated the need of using the two-component variance regression approach for the calibration of all the elements usually present in the environment at significant concentration levels. - Highlights: • Limit of detection was obtained considering a two variance component regression. • Calibration data may be affected by instrumental and operational conditions errors. • Calibration model was applied to determine 41 elements at trace level by ICP-MS. • Non instrumental errors were evidenced by PCA analysis

  20. Minimum emittance in TBA and MBA lattices

    Science.gov (United States)

    Xu, Gang; Peng, Yue-Mei

    2015-03-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 31/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design.

  1. Minimum emittance in TBA and MBA lattices

    International Nuclear Information System (INIS)

    Xu Gang; Peng Yuemei

    2015-01-01

    For reaching a small emittance in a modern light source, triple bend achromats (TBA), theoretical minimum emittance (TME) and even multiple bend achromats (MBA) have been considered. This paper derived the necessary condition for achieving minimum emittance in TBA and MBA theoretically, where the bending angle of inner dipoles has a factor of 3 1/3 bigger than that of the outer dipoles. Here, we also calculated the conditions attaining the minimum emittance of TBA related to phase advance in some special cases with a pure mathematics method. These results may give some directions on lattice design. (authors)

  2. Who Benefits from a Minimum Wage Increase?

    OpenAIRE

    John W. Lopresti; Kevin J. Mumford

    2015-01-01

    This paper addresses the question of how a minimum wage increase affects the wages of low-wage workers. Most studies assume that there is a simple mechanical increase in the wage for workers earning a wage between the old and the new minimum wage, with some studies allowing for spillovers to workers with wages just above this range. Rather than assume that the wages of these workers would have remained constant, this paper estimates how a minimum wage increase impacts a low-wage worker's wage...

  3. Wage inequality, minimum wage effects and spillovers

    OpenAIRE

    Stewart, Mark B.

    2011-01-01

    This paper investigates possible spillover effects of the UK minimum wage. The halt in the growth in inequality in the lower half of the wage distribution (as measured by the 50:10 percentile ratio) since the mid-1990s, in contrast to the continued inequality growth in the upper half of the distribution, suggests the possibility of a minimum wage effect and spillover effects on wages above the minimum. This paper analyses individual wage changes, using both a difference-in-differences estimat...

  4. SU-F-207-07: Dual-Energy Computed Tomography Detection Limit of Various Radiopaque Contrast Agents That Can Be Infused Within Absorbable Inferior Vena Cava Filters

    Energy Technology Data Exchange (ETDEWEB)

    Melancon, A; Jacobsen, M; Salatan, F; Jones, A; Cody, D; Nute, J; Melancon, M [U.T.M.D Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: Absorbable IVC filters are shown to be safe and efficacious in preventing pulmonary embolism. These absorbable filters disappear from the body after their required duration, alleviating costly removal procedures and downstream complications. Monitoring the positioning and integrity of absorbable devices using dual-energy computed tomography (DECT) would improve treatment efficacy. The purpose of this study is to determine the limit of detection and the energy dependence of DECT for various contrast agents that may be infused within the IVC filters including gold nanoparticles (AuNP) having diameters of 2 and 4 nm. Methods: All imaging studies were performed on a GE Discovery CT750 system in Gemstone Spectral Imaging (GSI) mode. Plastic vials containing the contrast agent solutions of water and blood were placed in a water bath, and images were acquired with the GSI-5 preset. The images were reformatted into the coronal plane and 5mm diameter ROIs were placed within each solution on a GE Advantage Workstation. Monoenergetic reconstructions were generated from 40 – 140 keV. Results: Mass attenuation (contrast per unit density) for AuNPs was greater than iron, but less than barium and iodine. Contrast was 10.2 (± 3.6) HU for 4 nm AuNP at 0.72 mg/ml and 12.1 (± 4.2) for 2 nm AuNP at 0.31 mg/ml at 70 keV suggesting reasonable chance of visualization at these concentrations for 70 keV reconstruction. The contrast as a function of CT energy is similar in both water and blood. Iodine is most dependent, followed closely by barium and iron, and trailed by a large margin by the AuNP. This was unexpected given Au’s large atomic number and the predominance of photoelectric effect at low energy. Conclusion: Infusion of IVC filters with AuNP is feasible. Discrimination of AuNP-infused IVC filters from surrounding anatomy warrants further investigation.

  5. How unprecedented a solar minimum was it?

    Science.gov (United States)

    Russell, C T; Jian, L K; Luhmann, J G

    2013-05-01

    The end of the last solar cycle was at least 3 years late, and to date, the new solar cycle has seen mainly weaker activity since the onset of the rising phase toward the new solar maximum. The newspapers now even report when auroras are seen in Norway. This paper is an update of our review paper written during the deepest part of the last solar minimum [1]. We update the records of solar activity and its consequent effects on the interplanetary fields and solar wind density. The arrival of solar minimum allows us to use two techniques that predict sunspot maximum from readings obtained at solar minimum. It is clear that the Sun is still behaving strangely compared to the last few solar minima even though we are well beyond the minimum phase of the cycle 23-24 transition.

  6. Impact of the Minimum Wage on Compression.

    Science.gov (United States)

    Wolfe, Michael N.; Candland, Charles W.

    1979-01-01

    Assesses the impact of increases in the minimum wage on salary schedules, provides guidelines for creating a philosophy to deal with the impact, and outlines options and presents recommendations. (IRT)

  7. Quantitative Research on the Minimum Wage

    Science.gov (United States)

    Goldfarb, Robert S.

    1975-01-01

    The article reviews recent research examining the impact of minimum wage requirements on the size and distribution of teenage employment and earnings. The studies measure income distribution, employment levels and effect on unemployment. (MW)

  8. Determining minimum lubrication film for machine parts

    Science.gov (United States)

    Hamrock, B. J.; Dowson, D.

    1978-01-01

    Formula predicts minimum film thickness required for fully-flooded ball bearings, gears, and cams. Formula is result of study to determine complete theoretical solution of isothermal elasto-hydrodynamic lubrication of fully-flooded elliptical contacts.

  9. Long Term Care Minimum Data Set (MDS)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Long-Term Care Minimum Data Set (MDS) is a standardized, primary screening and assessment tool of health status that forms the foundation of the comprehensive...

  10. [Storage of plant protection products in farms: minimum safety requirements].

    Science.gov (United States)

    Dutto, Moreno; Alfonzo, Santo; Rubbiani, Maristella

    2012-01-01

    Failure to comply with requirements for proper storage and use of pesticides in farms can be extremely hazardous and the risk of accidents involving farm workers, other persons and even animals is high. There are still wide differences in the interpretation of the concept of "securing or making safe", by workers in this sector. One of the critical points detected, particularly in the fruit sector, is the establishment of an adequate storage site for plant protection products. The definition of "safe storage of pesticides" is still unclear despite the recent enactment of Legislative Decree 81/2008 regulating health and work safety in Italy. In addition, there are no national guidelines setting clear minimum criteria for storage of plant protection products in farms. The authors, on the basis of their professional experience and through analysis of recent legislation, establish certain minimum safety standards for storage of pesticides in farms.

  11. Are There Long-Run Effects of the Minimum Wage?

    Science.gov (United States)

    Sorkin, Isaac

    2015-04-01

    An empirical consensus suggests that there are small employment effects of minimum wage increases. This paper argues that these are short-run elasticities. Long-run elasticities, which may differ from short-run elasticities, are policy relevant. This paper develops a dynamic industry equilibrium model of labor demand. The model makes two points. First, long-run regressions have been misinterpreted because even if the short- and long-run employment elasticities differ, standard methods would not detect a difference using US variation. Second, the model offers a reconciliation of the small estimated short-run employment effects with the commonly found pass-through of minimum wage increases to product prices.

  12. The SME gauge sector with minimum length

    Energy Technology Data Exchange (ETDEWEB)

    Belich, H.; Louzada, H.L.C. [Universidade Federal do Espirito Santo, Departamento de Fisica e Quimica, Vitoria, ES (Brazil)

    2017-12-15

    We study the gauge sector of the Standard Model Extension (SME) with the Lorentz covariant deformed Heisenberg algebra associated to the minimum length. In order to find and estimate corrections, we clarify whether the violation of Lorentz symmetry and the existence of a minimum length are independent phenomena or are, in some way, related. With this goal, we analyze the dispersion relations of this theory. (orig.)

  13. The SME gauge sector with minimum length

    Science.gov (United States)

    Belich, H.; Louzada, H. L. C.

    2017-12-01

    We study the gauge sector of the Standard Model Extension (SME) with the Lorentz covariant deformed Heisenberg algebra associated to the minimum length. In order to find and estimate corrections, we clarify whether the violation of Lorentz symmetry and the existence of a minimum length are independent phenomena or are, in some way, related. With this goal, we analyze the dispersion relations of this theory.

  14. RCoronae Borealis at the 2003 light minimum

    Science.gov (United States)

    Kameswara Rao, N.; Lambert, David L.; Shetrone, Matthew D.

    2006-08-01

    A set of five high-resolution optical spectra of R CrB obtained in 2003 March is discussed. At the time of the first spectrum (March 8), the star was at V = 12.6, a decline of more than six magnitudes. By March 31, the date of the last observation, the star at V = 9.3 was on the recovery to maximum light (V = 6). The 2003 spectra are compared with the extensive collection of spectra from the 1995-1996 minimum presented previously. Spectroscopic features common to the two minima include the familiar ones also seen in spectra of other R Coronae Borealis stars (RCBs) in decline: sharp emission lines of neutral and singly ionized atoms, broad emission lines including HeI, [NII] 6583 Å, Na D and CaII H & K lines, and blueshifted absorption lines of Na D, and KI resonance lines. Prominent differences between the 2003 and 1995-1996 spectra are seen. The broad Na D and Ca H & K lines in 2003 and 1995-1996 are centred approximately on the mean stellar velocity. The 2003 profiles are fit by a single Gaussian, but in 1995-1996 two Gaussians separated by about 200 km s-1 were required. However, the HeI broad emission lines are fit by a single Gaussian at all times; the emitting He and Na-Ca atoms are probably not colocated. The C2 Phillips 2-0 lines were detected as sharp absorption lines and the C2 Swan band lines as sharp emission lines in 2003, but in 1995-1996 the Swan band emission lines were broad and the Phillips lines were undetected. The 2003 spectra show CI sharp emission lines at minimum light with a velocity changing in 5 d by about 20 km s-1 when the velocity of `metal' sharp lines is unchanged; the CI emission may arise from shock-heated gas. Reexamination of spectra obtained at maximum light in 1995 shows extended blue wings to strong lines with the extension dependent on a line's lower excitation potential; this is the signature of a stellar wind, also revealed by published observations of the HeI 10830 Å line at maximum light. Changes in the cores of the

  15. [Cultural detection of thermotolerant Campylobacter spp. in food--potentials and limitations of diagnostic tools in the context of official food control].

    Science.gov (United States)

    Messelhäusser, Ute; Thärigen, Diana; Fella, Christiane; Schreiner, Hermann; Busch, Ulrich; Höller, Christiane

    2015-01-01

    Thermotolerant Campylobacter spp. rank among the most important foodborne pathogens in Germany. Therefore a necessity for rapid and routinely useable detection methods exists also in the area of food microbiology. A reliable, cultura qualitative, but also quantitative detection of thermotolerant Campylobacter spp. pose a challenge, at least concerning special food matrices, especially because in the context of official food control the cultural detection of thermotolerant Campylobacter spp. is needed. This was the reason, why different cultural detection methods, beside the standard procedure of ISO 10272:2006, in combination with molecular and immunological screening methods were tested at the Bavarian Health and Food Safety Authority (LGL) during the last years for the use in routine diagnostic using different food matrices of animal and plant origin. The results of the comparative studies showed clearly that no enrichment broth tested gave completely satisfactory results for an only culture-based detection the combination with a screening method is therefore recommended for a rapid and reliable detection. But in this case the user should take into account that the sensitivity of such molecular and immunological methods is normally so high that in some cases, depending on the food matrix and processing step, the isolation of the pathogen would not be possible in samples, which were positive in the screening methods.

  16. Beyond the obvious limits of ore deposits: The use of mineralogical, geochemical, and biological features for the remote detection of mineralization

    Science.gov (United States)

    Kelley, D.L.; Kelley, K.D.; Coker, W.B.; Caughlin, B.; Doherty, M.E.

    2006-01-01

    Far field features of ore deposits include mineralogical, geochemical, or biological attributes that can be recognized beyond the obvious limits of the deposits. They can be primary, if formed in association with mineralization or alteration processes, or secondary, if formed from the interaction of ore deposits with the hydrosphere and biosphere. This paper examines a variety of far field features of different ore deposit types and considers novel applications to exploration and discovery. Primary far field features include mineral and rock chemistry, isotopic or element halos, fluid pathways and thermal anomalies in host-rock sequences. Examples include the use of apatite chemistry to distinguish intrusive rocks permissive for iron oxide copper gold (IOCG) and porphyry deposits; resistate mineral (e.g., rutile, tourmaline) chemistry in exploration for volcanogenic massive sulfide (VMS), orogenic gold, and porphyry deposits; and pyrite chemistry to vector toward sedimentary exhalative (sedex) deposits. Distinctive whole-rock geochemical signatures also can be recognized as a far field feature of porphyry deposits. For example, unique Sr/Y ratios in whole-rock samples, used to distinguish barren versus fertile magmas for Cu mineralization, result from the differentiation of oxidized hydrous melts. Anomalous concentrations of halogen elements (Cl, Br, and I) have been found for distances of up to 200 m away from some mineralized centers. Variations in isotopic composition between ore-bearing and barren intrusions and/or systematic vertical and lateral zonation in sulfur, carbon, or oxygen isotope values have been documented for some deposit types. Owing to the thermal aureole that extends beyond the area of mineralization for some deposits, detection of paleothermal effects through methods such as conodont alteration indices, vitrinite or bitumen reflectance, illite crystallinity, and apatite or zircon thermochronology studies also can be valuable, particularly for

  17. The minimum wage in the Czech enterprises

    Directory of Open Access Journals (Sweden)

    Eva Lajtkepová

    2010-01-01

    Full Text Available Although the statutory minimum wage is not a new category, in the Czech Republic we encounter the definition and regulation of a minimum wage for the first time in the 1990 amendment to Act No. 65/1965 Coll., the Labour Code. The specific amount of the minimum wage and the conditions of its operation were then subsequently determined by government regulation in February 1991. Since that time, the value of minimum wage has been adjusted fifteenth times (the last increase was in January 2007. The aim of this article is to present selected results of two researches of acceptance of the statutory minimum wage by Czech enterprises. The first research makes use of the data collected by questionnaire research in 83 small and medium-sized enterprises in the South Moravia Region in 2005, the second one the data of 116 enterprises in the entire Czech Republic (in 2007. The data have been processed by means of the standard methods of descriptive statistics and of the appropriate methods of the statistical analyses (Spearman correlation coefficient of sequential correlation, Kendall coefficient, χ2 - independence test, Kruskal-Wallis test, and others.

  18. time of arrival 3-d position estimation using minimum ads-b receiver ...

    African Journals Online (AJOL)

    HOD

    The location from which a signal is transmitted can be estimated using the time it takes to be detected at a receiver. The difference between transmission time and the detection time is known as time of arrival (TOA). In this work, an algorithm for 3-dimensional (3-D) position estimation (PE) of an emitter using the minimum ...

  19. Decision Threshold and Detection Limit in Spectrometric Measurements. Part 1: Application to Gamma Spectrometry; Umbral de Decision y Limite de Deteccion en Medidas Espectrometricas. Parte 1: Aplicacion a la Espectrometria Gamma

    Energy Technology Data Exchange (ETDEWEB)

    Perez, C.; Gasco, C.; Lopez, M.A.

    2010-03-03

    This report summarised the author's lecture of the advanced gamma spectrometry course organised by CIEMAT. The characteristic limits determination in gamma spectrometry generally is obtained through the programming that the trade marks offers to the client with the objective of the automatic calculation of the activity concentrations existing in a sample. In this report, the examples shown in the ISO 11929 standard are compared to the programming realised by Genie 2k for determining characteristic limits. The main difference of both is located in the uncertainty calculations due to the efficiency calibration that is considered by ISO and not by Genie 2K. Through implementation in the software developed by trade marks will be possible to introduce this uncertainty and to assimilate to the calculation done by ISO 11929. In the second part of this report will be analyzed the more complicated samples of this application as counting in a whole body counter (following ISO-28218 about Performance Criteria for radio bioassay), multiplet, overlapping, addition of several peaks for obtaining the activity concentration, etc. (Author) 19 refs.

  20. Minimum entropy density method for the time series analysis

    Science.gov (United States)

    Lee, Jeong Won; Park, Joongwoo Brian; Jo, Hang-Hyun; Yang, Jae-Suk; Moon, Hie-Tae

    2009-01-01

    The entropy density is an intuitive and powerful concept to study the complicated nonlinear processes derived from physical systems. We develop the minimum entropy density method (MEDM) to detect the structure scale of a given time series, which is defined as the scale in which the uncertainty is minimized, hence the pattern is revealed most. The MEDM is applied to the financial time series of Standard and Poor’s 500 index from February 1983 to April 2006. Then the temporal behavior of structure scale is obtained and analyzed in relation to the information delivery time and efficient market hypothesis.