WorldWideScience

Sample records for mini-wright peak flow

  1. Peak expiratory flow rate in healthy children aged 6-17 years

    DEFF Research Database (Denmark)

    Høst, A; Høst, A H; Ibsen, T

    1994-01-01

    Peak expiratory flow rate (PEFR) was measured in a cross-sectional study in 861 healthy Danish schoolchildren aged 6-17 years using a Mini Wright peak flowmeter. We found a strong correlation between PEFR and height, age and sex. The results were comparable with those from previous studies using...... a Wright peak flowmeter. The equation for prediction of PEFR in boys was calculated as (3.8 x height) + (10.6 x age) - 313.2 (p age) - 143.9 (p ... coefficient in this large sample. Among healthy children without previous asthma, earlier episodes of recurrent wheezing were reported in 8.8% and a significantly lower PEFR was found in this group....

  2. Make peak flow a habit

    Science.gov (United States)

    Asthma - make peak flow a habit; Reactive airway disease - peak flow; Bronchial asthma - peak flow ... 2014:chap 55. National Asthma Education and Prevention Program website. How to use a peak flow meter. ...

  3. Decreased peak expiratory flow in pediatric passive smokers

    Directory of Open Access Journals (Sweden)

    Fitri Yanti

    2011-08-01

    Full Text Available Background Indonesia ranks fifth among countries with the highest aggregate levels of tobacco consumption in the world. Infants and children exposed to environmental tobacco smoke have increased rates of asthma, respiratory and ear infections, as well as reduced lung function. The effects of tobacco smoke exposure on lung function in children have been reported to be dependent on the source of smoke and the length and dose of exposure. Lung function may also be affected by a child’s gender and asthma status. Objective To compare peak expiratory flow (PEF in pediatric passive smokers to that of children not exposed to second hand smoke, and to define factors that may affect PEF in passive smokers. Methods In August 2009 we conducted a cross-sectional study at an elementary school in the Langkat district. Subjects were aged 6 to 12 years, and divided into two groups: passive smokers and those not exposed to secondhand smoke. Subjects’ PEFs were measured with a Mini-Wright peak flow meter. Measurements were performed in triplicate with the highest value recorded as the PEF. Demographic data including age, sex, weight, height, family income, parental education levels and occupations were obtained through questionnaires. Results Of the 170 participants, 100 were passive smokers and 70 were not exposed to secondhand smoke. Age distribution, weight and height were similar in both groups. We observed a significant difference in PEFs between the group of passive smokers and the group not exposed to secondhand smoke, 211.3 L/minute (SD 61.08 and 242.7 L/minute (SD 77.09, respectively (P < 0.005. The number of years of exposure to smoke (P = 0.079 and the number of cigarettes smoked daily in the household (P = 0.098 did not significantly influence PEF. Conclusion The PEF in pediatric passive smokers was significantly lower than that of children not exposed to secondhand smoke. PEF in passive smokers was not influenced by the number of years of smoke

  4. Inadequate peak expiratory flow meter characteristics detected by a computerised explosive decompression device

    DEFF Research Database (Denmark)

    Miller, M.R.; Atkins, P.R.; Pedersen, O.F.

    2003-01-01

    Methods: The dynamic response of mini-Wright (MW), Vitalograph (V), TruZone (TZ), MultiSpiro (MS) and pneumotachograph (PT) flow meters was tested by delivering two differently shaped flow-time profiles from a computer controlled explosive decompression device fitted with a fast response solenoid.......1) and 257 (39.2), respectively, and at ≈200 l/min they were 51 (23.9) and 1 (0.5). All the meters met ATS accuracy requirements when tested with their waveforms. Conclusions: An improved method for testing the dynamic response of flow meters detects marked overshoot (underdamping) of TZ and MS responses...

  5. How to use your peak flow meter

    Science.gov (United States)

    ... meter - how to use; Asthma - peak flow meter; Reactive airway disease - peak flow meter; Bronchial asthma - peak ... 2014:chap 55. National Asthma Education and Prevention Program website. How to use a peak flow meter. ...

  6. Peak expiratory flow rate in healthy rural school going children (5-16 years) of bellur region for construction of nomogram.

    Science.gov (United States)

    Cb, Manjunath; Sc, Kotinatot; Babu, Manjunatha

    2013-12-01

    Peak Expiratory Flow Rate (PEFR) recording is an essential measure in the management and evaluation of asthmatic children.It is helpful in monitoring disease progression and response to treatment. The PEFR can be measured by a simple instrument-peak expiratory flow meter. To construct nomogram of PEFR in healthy rural school going children from Mandya district of Karnataka state, India and to use these nomograms for comparison with that of children with obstructive lung diseases for this region. The study was conducted on Healthy rural school going children, both boys and girls between the age group of 5-16 years. For the determination of PEFR we used Mini Wright Peak Flow Meter. At three time measurement, the highest value of PEFR was recorded. Formula for prediction of PEFR was estimated by linear regression analysis after the correlation of PEFR with age and height for both boys and girls. PEFR was measured in 1028 children aged 5 to 16 years by using Wright's mini peak flow meter. Prediction equations were derived for PEFR with height in boys and girls. Normograms were plotted based on the observed values of PEFR in the study population. Significant linear correlation was seen of PEFR with height in boys (paffected by regional, environmental and anthropometric factors. Hence, it is necessary to have regional reference values for children. Among different factors affecting PEFR, height correlates better with PEFR than weight and sex. Hence nomograms constructed can be used for this region.

  7. Validity of peak expiratory flow measurement in assessing reversibility of airflow obstruction.

    Science.gov (United States)

    Dekker, F W; Schrier, A C; Sterk, P J; Dijkman, J H

    1992-01-01

    BACKGROUND: Assessing the reversibility of airflow obstruction by peak expiratory (PEF) measurements would be practicable in general practice, but its usefulness has not been investigated. METHODS: PEF measurements were performed (miniWright peak flow meter) in 73 general practice patients (aged 40 to 84) with a history of asthma or chronic obstructive lung disease before and after 400 micrograms inhaled sulbutamol. The change in PEF was compared with the change in forced expiratory volume in one second (FEV1). Reversible airflow obstruction was analysed in two ways according to previous criteria. When defined as a 9% or greater increase in FEV1 expressed as a percentage of predicted values reversibility was observed in 42% of patients. Relative operating characteristic analysis showed that an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (the sensitivity and specificity of an increase of 60 l/min in detecting a 9% or more increase in FEV1 as a percentage of predicted values were 68% and 93% respectively, with a positive predictive value of 87%). When defined as an increase of 190 ml or more in FEV1, reversible airflow obstruction was observed in 53% of patients. Again an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (sensitivity 56%, specificity 94%, and positive predictive value 92%). CONCLUSION: Absolute changes in PEF can be used as a simple technique to diagnose reversible airflow obstruction in patients from general practice. PMID:1519192

  8. ERGONOMIC CONSIDERATION OF THE EFFECT OF FLOUR DUST ON PEAK EXPIRATORY FLOW RATE OF BAKERS IN ABEOKUTA, OGUN STATE

    Directory of Open Access Journals (Sweden)

    Adekunle Ibrahim MUSA

    2017-06-01

    Full Text Available Flour dusts are one of the most harmful chemicals in the bakery industries which could lead to serious heart and lung diseases. This study investigated the effect of flour dust on Peak Expiratory Flow Rate of male bakers in Abeokuta, Ogun State, Nigeria with the relationship to the anthropometrical parameters. A total of One hundred Eighty (180 male participants were investigated, where ninety (90 participants were bakers and ninety (90 individuals as control group. The Peak expiratory flow rate (PEFR and anthropometrical parameters of the participant were measured using mini-Wright peak flow meter (PFM 20, OMRON and Detecto PD300MDHR (Cardinal Scale manufacturing company, USA column scale with digital height rod was used to measure body mass [kg] and height (cm respectively. The PEFR and anthropometrical parameters of the bakers and control groups were analysed using descriptive statistics and T-test with SPSS. The results showed that lower PEFR, 182.67 ± 16.34 L/min existed in bakers compared to 287.67 ± 17.02 L/min in the control study. The result also showed that a significant correlation exist between body mass, height and age (P < 0.01, PEFR, height (P < 0.05 and years of exposure (P < 0.01 of the bakers respectively. Furthermore, the results also showed that workers in the dusting and mixing of flour are at a risk of developing related pulmonary function impairment such as asthma. The study concluded that there is need to develop an effective intervention strategy, treatment seeking behaviour through awareness programs to prevent lung impairment diseases among the bakery workers.

  9. Instream flow needs below peaking hydroelectric projects

    International Nuclear Information System (INIS)

    Milhous, R.T.

    1991-01-01

    This paper reports on a method developed to assist in the determination of instream flow needs below hydroelectric projects operated in a peaking mode. Peaking hydroelectric projects significantly change streamflow over a short period of time; consequently, any instream flow methodology must consider the dual flows associated with peaking projects. The dual flows are the lowest flow and the maximum generation flow of a peaking cycle. The methodology is based on elements of the Physical Habitat Simulation System of the U.S. Fish and Wildlife Service and uses habitat, rather than fish numbers or biomas, as at basic response variable. All aquatic animals are subject to the rapid changes in streamflow which cause rapid swings in habitat quality. Some aquatic organisms are relatively fixed in location in the stream while others can move when flows change. The habitat available from a project operated in peaking mode is considered to be the minimum habitat occurring during a cycle of habitat change. The methodology takes in to consideration that some aquatic animals can move and others cannot move during a peaking cycle

  10. Study of Peak Expiratory Flow Rate as the Assessment of Lung Function in Occupationally Exposed Petrol Pump Workers of Western Maharashtra

    Directory of Open Access Journals (Sweden)

    Patil Smita V

    2016-04-01

    Full Text Available Background: Fast urbanization trends, rapid industrial growth, globalization, and poor environmental conditions at work places have created a lot of healthrelated issues. Aim and Objectives: The aim of this study is to investigate Peak Expiratory Flow Rate (PEFR as the assessment of lung function in occupationally exposed petrol pump workers and also check whether PEFR increases or decreases with duration of exposure. Material and Methods: The study was conducted on 60 male petrol pump workers between age group of 20-40 years who were working as petrol filling attendants for more than one year from western Maharashtra. 50 normal healthy males with same socioeconomic status were chosen as controls to find out the effect of occupational exposure to petroleum product on PEFR as the assessment of lung function tests. Petrol pump workers were divided into three groups based on their duration of exposure i.e. 1- 5 yrs, 6- 10 yrs and more than 11 years. PEFR of petrol pump workers and control was measured by using a Mini Wright peak flow meter which is a portable device for measuring ventilator functions. Comparisons was done using unpaired t-test for 2 groups comparisons and one way ANOVAfor multiple groups of exposures. Results: The PEFR was significantly lower decrease (p=0.001 around petrol pump workers (389.17 as compared to control (534.2. As year of exposure increased mean value of PEFR was significantly decreased from 452.17, 378.00 and 283.64 respectively in petrol pump workers. Conclusion: The results suggested that respiratory functions i.e. PEFR of occupationally exposed petrol pump workers are significantly reduced as compared to controls, also PEFR is significantly reduced with increase in the duration of exposure.

  11. Comparison of five portable peak flow meters.

    Science.gov (United States)

    Takara, Glaucia Nency; Ruas, Gualberto; Pessoa, Bruna Varanda; Jamami, Luciana Kawakami; Di Lorenzo, Valéria Amorim Pires; Jamami, Mauricio

    2010-05-01

    To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone, Assess, Galemed, Personal Best and Vitalograph peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (pmeters were 428 (263-688 L/min), 450 (350-800 L/min), 420 (310-720 L/min), 380 (300-735 L/min), 400 (310-685 L/min) and 415 (335-610 L/min), respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone(R) (pmeters. There was no agreement between the spirometric values and the five PEF meters. The results suggest that the values recorded from Galemed meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  12. Comparison of five portable peak flow meters

    Directory of Open Access Journals (Sweden)

    Glaucia Nency Takara

    2010-01-01

    Full Text Available OBJECTIVE: To compare the measurements of spirometric peak expiratory flow (PEF from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. METHODS: Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05, Spearman's correlation test and Bland-Altman's agreement test. RESULTS: The median and interquartile ranges for the spirometric values and the Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® meters were 428 (263-688 L/min, 450 (350-800 L/min, 420 (310-720 L/min, 380 (300-735 L/min, 400 (310-685 L/min and 415 (335-610 L/min, respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone® (p<0.001 and Galemed ® (p<0.01 meters. There was no agreement between the spirometric values and the five PEF meters. CONCLUSIONS: The results suggest that the values recorded from Galemed® meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone® meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  13. Peak Expiratory Flow Rate In Cigarette Smokers | Ukoli | Highland ...

    African Journals Online (AJOL)

    Objective: To compare lung function between smokers and non-smokers using Peak Expiratory Flow Rate (PEFR). Methods: This study examines the peak expiratory flow rate (PEFR) of three hundred and forty cigarette smokers, age and sex-matched with PEFR of equal number of non-smokers. Results: The mean PEFR of ...

  14. Effects of equipment and technique on peak flow measurements

    Directory of Open Access Journals (Sweden)

    O'Driscoll B Ronan

    2006-06-01

    Full Text Available Abstract Background Different lung function equipment and different respiratory manoeuvres may produce different Peak Expiratory Flow (PEF results. Although the PEF is the most common lung function test, there have been few studies of these effects and no previous study has evaluated both factors in a single group of patients. Methods We studied 36 subjects (PEF range 80–570 l/min. All patients recorded PEF measurements using a short rapid expiration following maximal inspiration (PEF technique or a forced maximal expiration to residual volume (FVC technique. Measurements were made using a Wright's peak flow meter, a turbine spirometer and a Fleisch pneumotachograph spirometer. Results The mean PEF was 8.7% higher when the PEF technique was used (compared with FVC technique, p Conclusion Peak flow measurements are affected by the instruction given and by the device and Peak Flow scale used. Patient management decisions should not be based on PEF measurement made on different instruments.

  15. flowPeaks: a fast unsupervised clustering for flow cytometry data via K-means and density peak finding.

    Science.gov (United States)

    Ge, Yongchao; Sealfon, Stuart C

    2012-08-01

    For flow cytometry data, there are two common approaches to the unsupervised clustering problem: one is based on the finite mixture model and the other on spatial exploration of the histograms. The former is computationally slow and has difficulty to identify clusters of irregular shapes. The latter approach cannot be applied directly to high-dimensional data as the computational time and memory become unmanageable and the estimated histogram is unreliable. An algorithm without these two problems would be very useful. In this article, we combine ideas from the finite mixture model and histogram spatial exploration. This new algorithm, which we call flowPeaks, can be applied directly to high-dimensional data and identify irregular shape clusters. The algorithm first uses K-means algorithm with a large K to partition the cell population into many small clusters. These partitioned data allow the generation of a smoothed density function using the finite mixture model. All local peaks are exhaustively searched by exploring the density function and the cells are clustered by the associated local peak. The algorithm flowPeaks is automatic, fast and reliable and robust to cluster shape and outliers. This algorithm has been applied to flow cytometry data and it has been compared with state of the art algorithms, including Misty Mountain, FLOCK, flowMeans, flowMerge and FLAME. The R package flowPeaks is available at https://github.com/yongchao/flowPeaks. yongchao.ge@mssm.edu Supplementary data are available at Bioinformatics online.

  16. Effects of peatland drainage management on peak flows

    OpenAIRE

    C. E. Ballard; N. McIntyre; H. S. Wheater

    2011-01-01

    Open ditch drainage has historically been a common land management practice in upland blanket peats, particularly in the UK. However, peatland drainage is now generally considered to have adverse effects on the upland environment, including increased peak flows. As a result, drain blocking has become a common management strategy in the UK over recent years, although there is only anecdotal evidence to suggest that this might decrease peak flows. The change in the hydrologica...

  17. Accuracy of portable devices in measuring peak cough flow

    International Nuclear Information System (INIS)

    Kulnik, Stefan Tino; Kalra, Lalit; MacBean, Victoria; Birring, Surinder Singh; Moxham, John; Rafferty, Gerrard Francis

    2015-01-01

    Peak cough flow (PCF) measurements can be used as indicators of cough effectiveness. Portable peak flow meters and spirometers have been used to measure PCF, but little is known about their accuracy compared to pneumotachograph systems. The aim of this study was to compare the accuracy of four portable devices (Mini–Wright and Assess peak flow meters, SpiroUSB and Microlab spirometers) in measuring PCF with a calibrated laboratory based pneumotachograph system. Twenty healthy volunteers (mean (SD) age 45 (16) years) coughed through a pneumotachograph connected in series with each portable device in turn, and the differences in PCF readings were analysed. In addition, mechanically generated flow waves of constant peak flow were delivered through each device both independently and when connected in series with the pneumotachograph. Agreement between PCF readings obtained with the pneumotachograph and the portable devices was poor. Peak flow readings were on average lower by approximately 50 L min −1 when measured using the portable devices; 95% limits of agreement spanned approximately 150 L min −1 . The findings highlight the potential for inaccuracy when using portable devices for the measurement of PCF. Depending on the measurement instrument used, absolute values of PCF reported in the literature may not be directly comparable. (paper)

  18. Superoxide dismutase levels and peak expiratory flow in asthmatic children

    Directory of Open Access Journals (Sweden)

    Arie Kurniasih

    2016-11-01

    Full Text Available Background Asthma is a chronic inflammatory process which involve variety of cells such as inflammatory mediators, reactive oxygen species (ROS, and cytokines. The inflammatory process would be exacerbated in the presence of oxidative stress. Superoxide dismutase (SOD is the first important enzyme to protect the respiratory tract against oxidative stress. The decreased of SOD has a correlation with increased of airway obstruction and bronchospasm. Objective To assess for a correlation between superoxide dismutase (SOD levels and peak expiratory flow, as well as to determine the impact of SOD levels for predicting asthma attacks. Methods We conducted a prospective cohort study at Dr. Sardjito Hospital, Yogyakarta, between February and April 2011 involving asthmatic children aged 5-18 years. Subjects’ serum SOD levels and peak expiratory flow were measured at the same time point. We then performed a prospective study following up on the same subjects to find out if they had a recurrent asthma attack within one month of the tests. We also reassessed their peak expiratory flow one month after blood specimens were obtained. Results Thirty-nine patients were enrolled in this study. There was no significant correlation between SOD level and peak expiratory flow [r=0.289; 95%CI -0.025 to 0.47; P=0.074]. However, older age was significantly associated with higher peak expiratory flow (=0.5; 95%CI 3.10 to 11.57; P=0.01. Lower levels of SOD increased the risk of asthma attacks in a month following the initial measurements (RR=5.5; 95%CI 1.6 to 18.9; P=0.009. Conclusion Superoxide dismutase (SOD level is not significantly associated with peak expiratory flow. However, we find a relationship between older age and higher peak expiratory flow and a relationship between lower SOD levels and risk of asthma attacks within one month following the tests.

  19. Effects of peatland drainage management on peak flows

    Directory of Open Access Journals (Sweden)

    C. E. Ballard

    2012-07-01

    Full Text Available Open ditch drainage has historically been a common land management practice in upland blanket peats, particularly in the UK. However, peatland drainage is now generally considered to have adverse effects on the upland environment, including increased peak flows. As a result, drain blocking has become a common management strategy in the UK over recent years, although there is only anecdotal evidence to suggest that this might decrease peak flows. The change in the hydrological regime associated with the drainage of blanket peat and the subsequent blocking of drains is poorly understood, therefore a new physics-based model has been developed that allows the exploration of the associated hydrological processes. A series of simulations is used to explore the response of intact, drained and blocked drain sites at field scales. While drainage is generally found to increase peak flows, the effect of drain blocking appears to be dependent on local conditions, sometimes decreasing and sometimes increasing peak flows. Based on insights from these simulations we identify steep smooth drains as those that would experience the greatest reduction in field-scale peak flows if blocked and recommend that future targeted field studies should be focused on examining surface runoff characteristics.

  20. factors influencing peak expiratory flow in teenage boys

    African Journals Online (AJOL)

    smoked. Regression analysis suggested peak flow differenct.s ... Medical Research Council Centre for Molecular and Cellular Biology, Department ... J leasure of lung function and a tool for asthma management.'.2 ... by the subjects were assigned a numerical value based on how .... Our data differ marginally from data.

  1. predicted peak expiratory flow in human and the clinical implication ...

    African Journals Online (AJOL)

    DR. AMINU

    predicted PEF varied widely across formulae and choice of a particular formula may alter guideline- base care. This work has therefore accepted a recently published population-base equation proposed as the reference standard for future asthma guidelines. Keywords: Peak expiratory flow, Asthma, Practice guidelines, ...

  2. Knowledge of spacer device, peak flow meter and inhaler technique ...

    African Journals Online (AJOL)

    Background: Metered dose inhalers are cornerstone in effective management of bronchial asthma when correctly used. Most studies hitherto have focused on assessing patient's knowledge of inhaler technique. We sought to assess the knowledge of inhaler technique, spacer device and peak flow meter among doctors and ...

  3. Factors influencing peak expiratory flow in teenage boys | van ...

    African Journals Online (AJOL)

    Background. Peak expiratory flow (PEF) is a useful measure of pulmonary health status and is frequently utilised in asthm, management. Reduction in PEF is usually indicative of onset (of asthma symptoms. However, use can be made of PEF values only if normal values are known. The definition of normal range is always ...

  4. The need for standardisation of peak flow charts

    OpenAIRE

    Reddel, H; Vincent, S; Civitico, J

    2005-01-01

    Peak expiratory flow (PEF) monitoring is recommended in asthma guidelines as a tool for assessing severity, monitoring response to treatment, detecting exacerbations, identifying triggers, and providing objective justification for treatment to the patient, but some clinicians have expressed concerns about its relevance in the management of asthma. We have identified a sevenfold variation in the scale of existing PEF charts, with resulting wide variation in the appearance of the same PEF date ...

  5. Peak-counts blood flow model-errors and limitations

    International Nuclear Information System (INIS)

    Mullani, N.A.; Marani, S.K.; Ekas, R.D.; Gould, K.L.

    1984-01-01

    The peak-counts model has several advantages, but its use may be limited due to the condition that the venous egress may not be negligible at the time of peak-counts. Consequently, blood flow measurements by the peak-counts model will depend on the bolus size, bolus duration, and the minimum transit time of the bolus through the region of interest. The effect of bolus size on the measurement of extraction fraction and blood flow was evaluated by injecting 1 to 30ml of rubidium chloride in the femoral vein of a dog and measuring the myocardial activity with a beta probe over the heart. Regional blood flow measurements were not found to vary with bolus sizes up to 30ml. The effect of bolus duration was studied by injecting a 10cc bolus of tracer at different speeds in the femoral vein of a dog. All intravenous injections undergo a broadening of the bolus duration due to the transit time of the tracer through the lungs and the heart. This transit time was found to range from 4-6 second FWHM and dominates the duration of the bolus to the myocardium for up to 3 second injections. A computer simulation has been carried out in which the different parameters of delay time, extraction fraction, and bolus duration can be changed to assess the errors in the peak-counts model. The results of the simulations show that the error will be greatest for short transit time delays and for low extraction fractions

  6. Changes in Peak Flow Value during Immunotherapy Administration

    International Nuclear Information System (INIS)

    Saporta, D.

    2012-01-01

    Nasal allergies are prevalent affecting a large percentage of the population. Not only the upper respiratory tract but the whole body is involved. Allergies produce morbidity (and even occasional mortality) as they can lead to asthma development, and increased number of accidents. Immunotherapy results can be evaluated by following symptom scores, medication use, and objective measurements. Using a Peak Flow Meter (Pf) to evaluate immunotherapy results, it became evident that patients with and without asthma exhibited an improvement in the Peak Flow (PF) value, suggesting that lower airway involvement in allergic patients could be more prevalent than assumed. A consecutive chart review was performed including patients of any age with nasal allergies (with or without asthma) treated with immunotherapy for at least 6 months that had at least 2 complete evaluations. When immunotherapy was successful, most patients exhibited an increase in the PF value regardless of asthma status. A very significant finding was that most allergy sufferers may have lower airway inflammation. The use of the PF value to assess immunotherapy results and the potential failure to diagnose asthma in allergy sufferers are discussed. A better diagnosis of lower airway inflammation could be substantial in the management of these patients pulmonary function

  7. 21 CFR 868.1860 - Peak-flow meter for spirometry.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Peak-flow meter for spirometry. 868.1860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1860 Peak-flow meter for spirometry. (a) Identification. A peak-flow meter for spirometry is a device used to measure a patient's...

  8. Improved simulation of peak flows under climate change: post-processing or composite opjective calibration?

    NARCIS (Netherlands)

    Zhang, Xujie; Booij, Martijn J.; Xu, YuePing

    2015-01-01

    Climate change is expected to have large impacts on peak flows. However, there may be bias in the simulation of peak flows by hydrological models. This study aims to improve the simulation of peak flows under climate change in Lanjiang catchment, east China, by comparing two approaches:

  9. Guiding Inspiratory Flow: Development of the In-Check DIAL G16, a Tool for Improving Inhaler Technique

    Directory of Open Access Journals (Sweden)

    Mark Jeremy Sanders

    2017-01-01

    Full Text Available Portable inhalers are divisible into those that deliver medication by patient triggering (pMDIs: a gentle slow inhalation and those that use the patient’s inspiratory effort as the force for deaggregation and delivery (DPIs: a stronger deeper inspiratory effort. Patient confusion and poor technique are commonplace. The use of training tools has become standard practice, and unique amongst these is an inspiratory flow meter (In-Check which is able to simulate the resistance characteristics of different inhalers and, thereby, guide the patient to the correct effort. In-Check’s origins lie in the 1960s peak expiratory flow meters, the development of the Mini-Wright peak flow meter, and inspiratory flow assessment via the nose during the 1970s–1980s. The current device (In-Check DIAL G16 is the third iteration of the original 1998 training tool, with detailed and ongoing assessments of all common inhaler resistances (including combination and breath-actuated inhaler types summarised into resistance ranges that are preset within the device. The device works by interpolating one of six ranges with the inspiratory effort. Use of the tool has been shown to be contributory to significant improvements in asthma care and control, and it is being advocated for assessment and training in irreversible lung disease.

  10. Historical changes in annual peak flows in Maine and implications for flood-frequency analyses

    Science.gov (United States)

    Hodgkins, Glenn A.

    2010-01-01

    Flood-frequency analyses use statistical methods to compute peak streamflows for selected recurrence intervals— the average number of years between peak flows that are equal to or greater than a specified peak flow. Analyses are based on annual peak flows at a stream. It has long been assumed that the annual peak streamflows used in these computations were stationary (non-changing) over very long periods of time, except in river basins subject to direct effects of human activities, such as urbanization and regulation. Because of the potential effects of global warming on peak flows, the assumption of peak-flow stationarity has recently been questioned. Maine has many streamgages with 50 to 105 years of recorded annual peak streamflows. In this study, this long-term record has been tested for historical flood-frequency stationarity, to provide some insight into future flood frequency. Changes over time in annual instantaneous peak streamflows at 28 U.S. Geological Survey streamgages with long-term data (50 or more years) and relatively complete records were investigated by examining linear trends for each streamgage’s period of record. None of the 28 streamgages had more than 5 years of missing data. Eight streamgages have substantial streamflow regulation. Because previous studies have suggested that changes over time may have occurred as a step change around 1970, step changes between each streamgage’s older record (start year to 1970) and newer record (1971 to 2006) also were computed. The median change over time for all 28 streamgages is an increase of 15.9 percent based on a linear change and an increase of 12.4 percent based on a step change. The median change for the 20 unregulated streamgages is slightly higher than for all 28 streamgages; it is 18.4 percent based on a linear change and 15.0 percent based on a step change. Peak flows with 100- and 5-year recurrence intervals were computed for the 28 streamgages using the full annual peak-flow record

  11. variations of peak expiratory flow rate with anthropometric

    African Journals Online (AJOL)

    admin

    Decreased bronchomotor tone would lead to a fall in airway resistance, and hence increased flow rate of air along it. Tests of. PEFR reflect changes in airway calibers. (Hughes and Empey, 1981). There have been reports on the variations of various ventilatory parameters with anthropometric determinants in. Nigerians.

  12. Reference values for peak flow and FEV1 variation in healthy schoolchildren using home spirometry

    NARCIS (Netherlands)

    Brouwer, A. F. J.; Duiverman, E. J.; Brand, P. L. P.

    2008-01-01

    Current reference values for diurnal peak flow variation in healthy children (median 8.2%; 95th percentile 31%) are so high that considerable overlap exists with those of asthmatic children. These values have been obtained using written peak flow diaries, which are unreliable. The aim of the present

  13. The U.S. Geological Survey Peak-Flow File Data Verification Project, 2008–16

    Science.gov (United States)

    Ryberg, Karen R.; Goree, Burl B.; Williams-Sether, Tara; Mason, Robert R.

    2017-11-21

    Annual peak streamflow (peak flow) at a streamgage is defined as the maximum instantaneous flow in a water year. A water year begins on October 1 and continues through September 30 of the following year; for example, water year 2015 extends from October 1, 2014, through September 30, 2015. The accuracy, characterization, and completeness of the peak streamflow data are critical in determining flood-frequency estimates that are used daily to design water and transportation infrastructure, delineate flood-plain boundaries, and regulate development and utilization of lands throughout the United States and are essential to understanding the implications of climate and land-use change on flooding and high-flow conditions.As of November 14, 2016, peak-flow data existed for 27,240 unique streamgages in the United States and its territories. The data, collectively referred to as the “peak-flow file,” are available as part of the U.S. Geological Survey (USGS) public web interface, the National Water Information System, at https://nwis.waterdata.usgs.gov/usa/nwis/peak. Although the data have been routinely subjected to periodic review by the USGS Office of Surface Water and screening at the USGS Water Science Center level, these data were not reviewed in a national, systematic manner until 2008 when automated scripts were developed and applied to detect potential errors in peak-flow values and their associated dates, gage heights, and peak-flow qualification codes, as well as qualification codes associated with the gage heights. USGS scientists and hydrographers studied the resulting output, accessed basic records and field notes, and corrected observed errors or, more commonly, confirmed existing data as correct.This report summarizes the changes in peak-flow file data at a national level, illustrates their nature and causation, and identifies the streamgages affected by these changes. Specifically, the peak-flow data were compared for streamgages with peak flow

  14. Lower crustal xenoliths, Chinese Peak lava flow, central Sierra Nevada.

    Science.gov (United States)

    Dodge, F.C.W.; Calk, L.C.; Kistler, R.W.

    1986-01-01

    This assemblage of pyroxenite, peridotite and mafic granulite xenoliths in the toe of a 10 m.y. trachybasalt flow remnant overlying late Cretaceous granitic rocks, indicates the presence of a mafic-ultramafic complex beneath this part of central California; orthopyroxenites, websterites and clinopyroxenites are dominant. A few of the xenoliths contain ovoid opaque patches that are apparently pseudomorphs after garnet and have pyralspite garnet compositions; using a garnet-orthopyroxene geobarometer, they indicate a lower crustal depth of approx 40 km. Abundant mafic granulites can be subdivided into those with Al2O3 = or 15% and showing considerable scatter on oxide variation diagrams. The high-alumina granulite xenoliths have relatively low 87Rb/86Sr but high 87Sr/86Sr, whereas the low-alumina and ultramafic xenoliths have a wide range of 87Rb/86Sr, but lower 87Sr/86Sr; the isotopic data indicate roughly the same age as that of overlying granitic plutons (approx 100 m.y.). However, the granitic rocks have initial 87Sr/86Sr ratios intermediate between those of the high-alumina and ultramafic xenoliths, suggesting that they result from the mixing of basaltic magma (represented by the ultramafic rocks) and crustal materials, with subsequent crystal fractionation.-R.A.H.

  15. Scaling of peak flows with constant flow velocity in random self-similar networks

    Directory of Open Access Journals (Sweden)

    R. Mantilla

    2011-07-01

    Full Text Available A methodology is presented to understand the role of the statistical self-similar topology of real river networks on scaling, or power law, in peak flows for rainfall-runoff events. We created Monte Carlo generated sets of ensembles of 1000 random self-similar networks (RSNs with geometrically distributed interior and exterior generators having parameters pi and pe, respectively. The parameter values were chosen to replicate the observed topology of real river networks. We calculated flow hydrographs in each of these networks by numerically solving the link-based mass and momentum conservation equation under the assumption of constant flow velocity. From these simulated RSNs and hydrographs, the scaling exponents β and φ characterizing power laws with respect to drainage area, and corresponding to the width functions and flow hydrographs respectively, were estimated. We found that, in general, φ > β, which supports a similar finding first reported for simulations in the river network of the Walnut Gulch basin, Arizona. Theoretical estimation of β and φ in RSNs is a complex open problem. Therefore, using results for a simpler problem associated with the expected width function and expected hydrograph for an ensemble of RSNs, we give heuristic arguments for theoretical derivations of the scaling exponents β(E and φ(E that depend on the Horton ratios for stream lengths and areas. These ratios in turn have a known dependence on the parameters of the geometric distributions of RSN generators. Good agreement was found between the analytically conjectured values of β(E and φ(E and the values estimated by the simulated ensembles of RSNs and hydrographs. The independence of the scaling exponents φ(E and φ with respect to the value of flow velocity and runoff intensity implies an interesting connection between unit

  16. Scaling of peak flows with constant flow velocity in random self-similar networks

    Science.gov (United States)

    Troutman, Brent M.; Mantilla, Ricardo; Gupta, Vijay K.

    2011-01-01

    A methodology is presented to understand the role of the statistical self-similar topology of real river networks on scaling, or power law, in peak flows for rainfall-runoff events. We created Monte Carlo generated sets of ensembles of 1000 random self-similar networks (RSNs) with geometrically distributed interior and exterior generators having parameters pi and pe, respectively. The parameter values were chosen to replicate the observed topology of real river networks. We calculated flow hydrographs in each of these networks by numerically solving the link-based mass and momentum conservation equation under the assumption of constant flow velocity. From these simulated RSNs and hydrographs, the scaling exponents β and φ characterizing power laws with respect to drainage area, and corresponding to the width functions and flow hydrographs respectively, were estimated. We found that, in general, φ > β, which supports a similar finding first reported for simulations in the river network of the Walnut Gulch basin, Arizona. Theoretical estimation of β and φ in RSNs is a complex open problem. Therefore, using results for a simpler problem associated with the expected width function and expected hydrograph for an ensemble of RSNs, we give heuristic arguments for theoretical derivations of the scaling exponents β(E) and φ(E) that depend on the Horton ratios for stream lengths and areas. These ratios in turn have a known dependence on the parameters of the geometric distributions of RSN generators. Good agreement was found between the analytically conjectured values of β(E) and φ(E) and the values estimated by the simulated ensembles of RSNs and hydrographs. The independence of the scaling exponents φ(E) and φ with respect to the value of flow velocity and runoff intensity implies an interesting connection between unit hydrograph theory and flow dynamics. Our results provide a reference framework to study scaling exponents under more complex scenarios

  17. Evaluation of Peak Expiratory Flow Rates (PEFR) of Workers in a ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    and knowledge of occupational health associated with the ... the respiratory system with significant. 5 ... Peak Expiratory Flow Rates (PEFR) of workers in a cement factory — Douglas K. E, Alasia D. D. ... history of cigarette smoking and chronic.

  18. Peak expiratory flow variability, bronchial responsiveness, and susceptibility to ambient air pollution in adults

    NARCIS (Netherlands)

    Boezen, M; Schouten, Jan; Rijcken, B; Vonk, J; Gerritsen, J; Hoek, G; Brunekreef, B; Postma, D

    1998-01-01

    Bronchial hyperresponsiveness (BHR) and peak expiratory flow (PEF) variability are associated expressions of airway lability, yet probably reflect different underlying pathophysiologic mechanisms. We investigated whether both measures can be used interchangeably to identify subjects who are

  19. Wavelet transform for the evaluation of peak intensities in flow-injection analysis

    NARCIS (Netherlands)

    Bos, M.; Hoogendam, E.

    1992-01-01

    The application of the wavelet transform in the determination of peak intensities in flow-injection analysis was studied with regard to its properties of minimizing the effects of noise and baseline drift. The results indicate that for white noise and a favourable peak shape a signal-to-noise ratio

  20. Wavelett transform for the evaluation of peak intensities in flow-injection analysis

    NARCIS (Netherlands)

    Bos, M.; Hoogendam, E.; Hoogendam, E.

    1992-01-01

    The application of the wavelet transform in the determination of peak intensities in flow-injection analysis was studied with regard to its properties of minimizing the effects of noise and baseline drift. The results indicate that for white noise and a favourable peak shape a signal-to-noise ratio

  1. Reference values of fetal peak systolic blood flow Velocity in the ...

    African Journals Online (AJOL)

    Objectives: The objectives of this prospective cross sectional study are (i) to establish new reference values of peak systolic blood flow velocity measurement in the fetal middle cerebral artery (MCA-PSV) following validated methodological guidelines (ii) to correlate peak systolic velocity with gestational age and (iii) to ...

  2. A fluid dynamical flow model for the central peak in the rotation curve of disk galaxies

    International Nuclear Information System (INIS)

    Bhattacharyya, T.; Basu, B.

    1980-01-01

    The rotation curve of the central region in some disk galaxies shows a linear rise, terminating at a peak (primary peak) which is then vollowed by a deep minimum. The curve then again rises to another peak at more or less half-way across the galactic radius. This latter peak is considered as the peak of the rotation curve in all large-scale analysis of galactic structure. The primary peak is usually ignored for the purpose. In this work an attempt has been made to look at the primary peak as the manifestation of the post-explosion flow pattern of gas in the deep central region of galaxies. Solving hydrodynamical equations of motion, a flow model has been derived which imitates very closely the actually observed linear rotational velocity, followed by the falling branch of the curve to minimum. The theoretical flow model has been compared with observed results for nine galaxies. The agreement obtained is extremely encouraging. The distance of the primary peak from the galactic centre has been shown to be correlated with the angular velocity in the linear part of the rotation curve. Here also, agreement is very good between theoretical and observed results. It is concluded that the distance of the primary peak from the centre not only speaks of the time that has elapsed since the explosion occurred in the nucleus, it also speaks of the potential capability of the nucleus of the galaxy for repeating explosions through some efficient process of mass replenishment at the core. (orig.)

  3. Influence of peak flow changes on the macroinvertebrate drift downstream of a Brazilian hydroelectric dam.

    Science.gov (United States)

    Castro, D M P; Hughes, R M; Callisto, M

    2013-11-01

    Successive daily peak flows from hydropower plants can disrupt aquatic ecosystems and alter the composition and structure of macroinvertebrates downstream. We evaluated the influence of peak flow changes on macroinvertebrate drift downstream of a hydroelectric plant as a basis for determining ecological flows that might reduce the disturbance of aquatic biota. The aim of this study was to assess the influence of flow fluctuations on the seasonal and daily drift patterns of macroinvertebrates. We collected macroinvertebrates during fixed flow rates (323 m3.s-1 in the wet season and 111 m3.s-1 in the dry season) and when peak flows fluctuated (378 to 481 m3.s-1 in the wet season, and 109 to 173 m3.s-1 in the dry season) in 2010. We collected 31,924 organisms belonging to 46 taxa in the four sampling periods. Taxonomic composition and densities of drifting invertebrates differed between fixed and fluctuating flows, in both wet and dry seasons, but family richness varied insignificantly. We conclude that macroinvertebrate assemblages downstream of dams are influenced by daily peak flow fluctuations. When making environmental flow decisions for dams, it would be wise to consider drifting macroinvertebrates because they reflect ecological changes in downstream biological assemblages.

  4. Predicting Extubation Outcome by Cough Peak Flow Measured Using a Built-in Ventilator Flow Meter.

    Science.gov (United States)

    Gobert, Florent; Yonis, Hodane; Tapponnier, Romain; Fernandez, Raul; Labaune, Marie-Aude; Burle, Jean-François; Barbier, Jack; Vincent, Bernard; Cleyet, Maria; Richard, Jean-Christophe; Guérin, Claude

    2017-12-01

    Successful weaning from mechanical ventilation depends on the patient's ability to cough efficiently. Cough peak flow (CPF) could predict extubation success using a dedicated flow meter but required patient disconnection. We aimed to predict extubation outcome using an overall model, including cough performance assessed by a ventilator flow meter. This was a prospective observational study conducted from November 2014 to October 2015. Before and after a spontaneous breathing trial, subjects were encouraged to cough as strongly as possible before freezing the ventilator screen to assess CPF and tidal volume (V T ) in the preceding inspiration. Early extubation success rate was defined as the proportion of subjects not re-intubated 48 h after extubation. Diagnostic performance of CPF and V T was assessed by using the area under the curve of the receiver operating characteristic curve. Cut-off values for CPF and V T were defined according to median values and used to describe the performance of a predictive test combining them with risk factors of early extubation failure. Among 673 subjects admitted, 92 had a cough assessment before extubation. For the 81 subjects with early extubation success, the median CPF was -67.7 L/min, and median V T was 0.646 L. For the 11 subjects with early extubation failure, the median CPF was -57.3 L/min, and median V T was 0.448 L. Area under the curve was 0.61 (95% CI 0.37-0.83) for CPF and 0.64 (95% CI 0.42-0.84) for CPF/V T combined. After dichotomization (CPF 0.55 L), there was a synergistic effect to predict early extubation success ( P meter of an ICU ventilator was able to predict extubation success and to build a composite score to predict extubation failure. The results were close to that found in previous studies that used a dedicated flow meter. This could help to identify high-risk subjects to prevent extubation failure. (ClinicalTrials.gov registration NCT02847221.). Copyright © 2017 by Daedalus Enterprises.

  5. Dispersion-convolution model for simulating peaks in a flow injection system.

    Science.gov (United States)

    Pai, Su-Cheng; Lai, Yee-Hwong; Chiao, Ling-Yun; Yu, Tiing

    2007-01-12

    A dispersion-convolution model is proposed for simulating peak shapes in a single-line flow injection system. It is based on the assumption that an injected sample plug is expanded due to a "bulk" dispersion mechanism along the length coordinate, and that after traveling over a distance or a period of time, the sample zone will develop into a Gaussian-like distribution. This spatial pattern is further transformed to a temporal coordinate by a convolution process, and finally a temporal peak image is generated. The feasibility of the proposed model has been examined by experiments with various coil lengths, sample sizes and pumping rates. An empirical dispersion coefficient (D*) can be estimated by using the observed peak position, height and area (tp*, h* and At*) from a recorder. An empirical temporal shift (Phi*) can be further approximated by Phi*=D*/u2, which becomes an important parameter in the restoration of experimental peaks. Also, the dispersion coefficient can be expressed as a second-order polynomial function of the pumping rate Q, for which D*(Q)=delta0+delta1Q+delta2Q2. The optimal dispersion occurs at a pumping rate of Qopt=sqrt[delta0/delta2]. This explains the interesting "Nike-swoosh" relationship between the peak height and pumping rate. The excellent coherence of theoretical and experimental peak shapes confirms that the temporal distortion effect is the dominating reason to explain the peak asymmetry in flow injection analysis.

  6. Tests of peak flow scaling in simulated self-similar river networks

    Science.gov (United States)

    Menabde, M.; Veitzer, S.; Gupta, V.; Sivapalan, M.

    2001-01-01

    The effect of linear flow routing incorporating attenuation and network topology on peak flow scaling exponent is investigated for an instantaneously applied uniform runoff on simulated deterministic and random self-similar channel networks. The flow routing is modelled by a linear mass conservation equation for a discrete set of channel links connected in parallel and series, and having the same topology as the channel network. A quasi-analytical solution for the unit hydrograph is obtained in terms of recursion relations. The analysis of this solution shows that the peak flow has an asymptotically scaling dependence on the drainage area for deterministic Mandelbrot-Vicsek (MV) and Peano networks, as well as for a subclass of random self-similar channel networks. However, the scaling exponent is shown to be different from that predicted by the scaling properties of the maxima of the width functions. ?? 2001 Elsevier Science Ltd. All rights reserved.

  7. Ultrasonic 3-D Vector Flow Method for Quantitative In Vivo Peak Velocity and Flow Rate Estimation

    DEFF Research Database (Denmark)

    Holbek, Simon; Ewertsen, Caroline; Bouzari, Hamed

    2017-01-01

    Current clinical ultrasound (US) systems are limited to show blood flow movement in either 1-D or 2-D. In this paper, a method for estimating 3-D vector velocities in a plane using the transverse oscillation method, a 32×32 element matrix array, and the experimental US scanner SARUS is presented...... is validated in two phantom studies, where flow rates are measured in a flow-rig, providing a constant parabolic flow, and in a straight-vessel phantom ( ∅=8 mm) connected to a flow pump capable of generating time varying waveforms. Flow rates are estimated to be 82.1 ± 2.8 L/min in the flow-rig compared...

  8. Exogenous stimuli and circadian peak expiratory flow variation in allergic asthmatic children

    NARCIS (Netherlands)

    Meijer, G. G.; Postma, D. S.; van der Heide, S.; de Reus, D. M.; Roorda, R. J.; Koëter, G. H.; van Aalderen, W. M.

    1996-01-01

    The influence of exogenous factors in the home on the circadian variation of airway obstruction has not been fully assessed in children with asthma. The aim of the present study was to investigate the contribution of exogenous stimuli to the degree of peak expiratory flow (PEF) variability during 24

  9. Seasonal variations in house dust mite influence the circadian peak expiratory flow amplitude

    NARCIS (Netherlands)

    Postma, DS; vanderHeide, S; deReus, DM; Koeter, GH; vanAalderen, WMC; Meijer, G.

    1996-01-01

    The aim of the study was to investigate whether seasonal differences in house dust mite (HDM) allergen exposure influence the circadian peak expiratory flow (PEF) amplitude in asthmatic children. Asthmatic children (n = 25) with a solitary allergy to HDM were studied in spring and in autumn. All

  10. Exogenous stimuli and circadian peak expiratory flow variation in allergic asthmatic children

    NARCIS (Netherlands)

    Postma, DS; VanderHeide, S; DeReus, DM; Koeter, GH; VanAalderen, WMC; Meijer, G.

    The influence of exogenous factors in the home on the circadian variation of airway obstruction has not been fully assessed in children with asthma. The aim of the present study was to investigate the contribution of exogenous stimuli to the degree of peak expiratory flow (PEF) variability during 24

  11. Peak flow variation in childhood asthma : Relationship to symptoms, atopy, airways obstruction and hyperresponsiveness

    NARCIS (Netherlands)

    Brand, PLP; Duiverman, EJ; Postma, DS; Waalkens, HJ; Kerrebijn, KF; vanEssenZandvliet, EEM; Quanjer, PH; Sluiter, HJ; Pouw, EM; Schoonbrood, DFME; Roos, CM; Jansen, HM; DeGooijer, A; Kerstjens, HAM; vanderMark, TW; Koeter, GH; deJong, PM; Sterk, PJ; Weaver, AMJ; Dijkman, JH; Dekhuijzen, PNR; Folgering, HTM; vanHerwaarden, CLA; Overbeek, SE; Bogaard, JM; Hilvering, C; Gans, SJ; Mengelers, HJJ; vanderBruggenBogaarts, BAHA; Kreukniet, J; Kouwenberg, JM; Prinsen, JE; Gerritsen, J; Knol, K; deMonchy, JGR; Dekker, FW; Kaptein, AA; Merkus, PJFM; Pocock, SJ; Hughes, MD; Robinson, NJ; Bleecker, ER; Meyers, DA

    Although home recording of peak expiratory flow (PEF) is considered useful in managing asthma, little is known about the relationship of PEF variation to other indicators of disease activity, We examined the relationship of PEF variation, expressed in various ways, to symptoms, atopy, level of lung

  12. Effects of non-uniform core flow on peak cladding temperature: MOXY/SCORE sensitivity calculations

    Energy Technology Data Exchange (ETDEWEB)

    Chang, S.C.

    1979-08-15

    The MOXY/SCORE computer program is used to evaluate the potential effect on peak cladding temperature of selective cooling that may result from a nonuniform mass flux at the core boundaries during the blowdown phase of the LOFT L2-4 test. The results of this study indicate that the effect of the flow nonuniformity at the core boundaries will be neutralized by a strong radial flow redistribution in the neighborhood of core boundaries. The implication is that the flow nonuniformity at the core boundaries has no significant effect on the thermal-hydraulic behavior and cladding temperature at the hot plane.

  13. Effects of non-uniform core flow on peak cladding temperature: MOXY/SCORE sensitivity calculations

    International Nuclear Information System (INIS)

    Chang, S.C.

    1979-01-01

    The MOXY/SCORE computer program is used to evaluate the potential effect on peak cladding temperature of selective cooling that may result from a nonuniform mass flux at the core boundaries during the blowdown phase of the LOFT L2-4 test. The results of this study indicate that the effect of the flow nonuniformity at the core boundaries will be neutralized by a strong radial flow redistribution in the neighborhood of core boundaries. The implication is that the flow nonuniformity at the core boundaries has no significant effect on the thermal-hydraulic behavior and cladding temperature at the hot plane

  14. Peak Flow Responses and Recession Flow Characteristics After Thinning of Japanese Cypress Forest in a Headwater Catchment

    Science.gov (United States)

    We evaluated the effects of forest thinning on peak flow and recession characteristics of storm runoff in headwater catchments at Mie Prefecture, Japan. In catchment M5, 58.3% of stems were removed, whereas catchment M4 remained untreated as a control catchment. Storm precipitati...

  15. Geomorphic and hydrologic study of peak-flow management on the Cedar River, Washington

    Science.gov (United States)

    Magirl, Christopher S.; Gendaszek, Andrew S.; Czuba, Christiana R.; Konrad, Christopher P.; Marineau, Mathieu D.

    2012-01-01

    Assessing the linkages between high-flow events, geomorphic response, and effects on stream ecology is critical to river management. High flows on the gravel-bedded Cedar River in Washington are important to the geomorphic function of the river; however, high flows can deleteriously affect salmon embryos incubating in streambed gravels. A geomorphic analysis of the Cedar River showed evidence of historical changes in river form over time and quantified the effects of anthropogenic alterations to the river corridor. Field measurements with accelerometer scour monitors buried in the streambed provided insight into the depth and timing of streambed scour during high-flow events. Combined with a two-dimensional hydrodynamic model, the recorded accelerometer disturbances allowed the prediction of streambed disturbance at the burial depth of Chinook and sockeye salmon egg pockets for different peak discharges. Insight gained from these analyses led to the development of suggested monitoring metrics for an ongoing geomorphic monitoring program on the Cedar River.

  16. Peak expiratory flow as a predictor for the effectiveness of sport for patients with COPD.

    Science.gov (United States)

    Jungblut, S; Frickmann, H; Klingler, J; Zimmermann, B; Bargon, Joachim

    2006-01-31

    This study intended to find simple parameters that were able to determine the increase in physical performance as a result of sport in a group of patients with COPD (lung sport). We regularly investigated pulse, oxygenation and peak expiratory flow in participants with COPD of a "lung sport group", who participated in a structured weekly training program under professional supervision. Ten volunteers (7 females, 3 males, median of age = 69) with COPD (grade II-III) took part in the study. - The relative changes after 3 and 6 months were compared with the values of the first month of exercise. Measurements were carried out before exercise, after stamina training and at the end of the program. - Pulse and oxygenation did not show any changes. However, there was a significant improvement of peak flow after 6 months. - These peak flow changes represent further evidence of positive effects of sport in COPD and provide a parameter which allows the patients themselves to measure and evaluate the success of their physical activity.

  17. Flow-Cell-Induced Dispersion in Flow-through Absorbance Detection Systems: True Column Effluent Peak Variance.

    Science.gov (United States)

    Dasgupta, Purnendu K; Shelor, Charles Phillip; Kadjo, Akinde Florence; Kraiczek, Karsten G

    2018-02-06

    Following a brief overview of the emergence of absorbance detection in liquid chromatography, we focus on the dispersion caused by the absorbance measurement cell and its inlet. A simple experiment is proposed wherein chromatographic flow and conditions are held constant but a variable portion of the column effluent is directed into the detector. The temporal peak variance (σ t,obs 2 ), which increases as the flow rate (F) through the detector decreases, is found to be well-described as a quadratic function of 1 / F . This allows the extrapolation of the results to zero residence time in the detector and thence the determination of the true variance of the peak prior to the detector (this includes contribution of all preceding components). This general approach should be equally applicable to detection systems other than absorbance. We also experiment where the inlet/outlet system remains the same but the path length is varied. This allows one to assess the individual contributions of the cell itself and the inlet/outlet system.to the total observed peak. The dispersion in the cell itself has often been modeled as a flow-independent parameter, dependent only on the cell volume. Except for very long path/large volume cells, this paradigm is simply incorrect.

  18. PROGRESSIVE MUSCLE RELAXATION INCREASE PEAK EXPIRATORY FLOW RATE ON CHRONIC OBSTRUCTIVE PULMONARY DISEASE PATIENTS

    Directory of Open Access Journals (Sweden)

    Tintin Sukartini

    2017-07-01

    Full Text Available Introduction: Limited progressive air flow in Chronic Obstructive Pulmonary Disease (COPD can caused by small airway disease (bronchiolitis obstructive and loss of elasticity of the lung (emphysema. Further it can be decreasing the quality of life in COPD patients because dyspnea and uncomfortable in activity. Progressive muscle relaxation (PMR is one of the relaxation technique that can repair pulmonary ventilation by decreasing chronic constriction of the respiratory muscles. The objective of this study was to analyze the effect of progressive muscle relaxation on raised peak expiratory flow rate (PEFR. Method: A pre-experimental one group pre-post test design was used in this study. Population was all of the COPD patients at Pulmonary Specialist Polyclinic Dr Mohamad Soewandhie Surabaya. There were 8 respondents taken by using purposive sampling. PEFR was counted by using peak flow meter every six day. Data were analyzed by using Paired t-Test with significance level  p≤0.05. Result: The result showed that PMR had significance level on increasing of PEFR (p=0.012. Discussion: It can be concluded that PMR has an effect on raise PEFR. Further studies are recommended to measure the effect of PMR on respiratory rate (RR, heart rate (HR subjective dyspnoe symptoms, forced expiration volume on the first minute (FEV1 and mid maximum flow rate (MMFR in COPD patients.

  19. Uncertainty of the peak flow reconstruction of the 1907 flood in the Ebro River in Xerta (NE Iberian Peninsula)

    Science.gov (United States)

    Ruiz-Bellet, Josep Lluís; Castelltort, Xavier; Balasch, J. Carles; Tuset, Jordi

    2017-02-01

    There is no clear, unified and accepted method to estimate the uncertainty of hydraulic modelling results. In historical floods reconstruction, due to the lower precision of input data, the magnitude of this uncertainty could reach a high value. With the objectives of giving an estimate of the peak flow error of a typical historical flood reconstruction with the model HEC-RAS and of providing a quick, simple uncertainty assessment that an end user could easily apply, the uncertainty of the reconstructed peak flow of a major flood in the Ebro River (NE Iberian Peninsula) was calculated with a set of local sensitivity analyses on six input variables. The peak flow total error was estimated at ±31% and water height was found to be the most influential variable on peak flow, followed by Manning's n. However, the latter, due to its large uncertainty, was the greatest contributor to peak flow total error. Besides, the HEC-RAS resulting peak flow was compared to the ones obtained with the 2D model Iber and with Manning's equation; all three methods gave similar peak flows. Manning's equation gave almost the same result than HEC-RAS. The main conclusion is that, to ensure the lowest peak flow error, the reliability and precision of the flood mark should be thoroughly assessed.

  20. Fluid flow distribution optimization for minimizing the peak temperature of a tubular solar receiver

    International Nuclear Information System (INIS)

    Wei, Min; Fan, Yilin; Luo, Lingai; Flamant, Gilles

    2015-01-01

    High temperature solar receiver is a core component of solar thermal power plants. However, non-uniform solar irradiation on the receiver walls and flow maldistribution of heat transfer fluid inside the tubes may cause the excessive peak temperature, consequently leading to the reduced lifetime. This paper presents an original CFD (computational fluid dynamics)-based evolutionary algorithm to determine the optimal fluid distribution in a tubular solar receiver for the minimization of its peak temperature. A pressurized-air solar receiver comprising of 45 parallel tubes subjected to a Gaussian-shape net heat flux absorbed by the receiver is used for study. Two optimality criteria are used for the algorithm: identical outlet fluid temperatures and identical temperatures on the centerline of the heated surface. The influences of different filling materials and thermal contact resistances on the optimal fluid distribution and on the peak temperature reduction are also evaluated and discussed. Results show that the fluid distribution optimization using the algorithm could minimize the peak temperature of the receiver under the optimality criterion of identical temperatures on the centerline. Different shapes of optimal fluid distribution are determined for various filling materials. Cheap material with low thermal conductivity can also meet the peak temperature threshold through optimizing the fluid distribution. - Highlights: • A 3D pressurized-air solar receiver based on the tube-in-matrix concept is studied. • An original evolutionary algorithm is developed for fluid distribution optimization. • A new optimality criterion is proposed for minimizing the receiver peak temperature. • Different optimal fluid distributions are determined for various filling materials. • Filling material with high thermal conductivity is more favorable in practical use.

  1. Generalized Skew Coefficients of Annual Peak Flows for Rural, Unregulated Streams in West Virginia

    Science.gov (United States)

    Atkins, John T.; Wiley, Jeffrey B.; Paybins, Katherine S.

    2009-01-01

    Generalized skew was determined from analysis of records from 147 streamflow-gaging stations in or near West Virginia. The analysis followed guidelines established by the Interagency Advisory Committee on Water Data described in Bulletin 17B, except that stations having 50 or more years of record were used instead of stations with the less restrictive recommendation of 25 or more years of record. The generalized-skew analysis included contouring, averaging, and regression of station skews. The best method was considered the one with the smallest mean square error (MSE). MSE is defined as the following quantity summed and divided by the number of peaks: the square of the difference of an individual logarithm (base 10) of peak flow less the mean of all individual logarithms of peak flow. Contouring of station skews was the best method for determining generalized skew for West Virginia, with a MSE of about 0.2174. This MSE is an improvement over the MSE of about 0.3025 for the national map presented in Bulletin 17B.

  2. VO(2peak), myocardial hypertrophy, and myocardial blood flow in endurance-trained men.

    Science.gov (United States)

    Laaksonen, Marko S; Heinonen, Ilkka; Luotolahti, Matti; Knuuti, Juhani; Kalliokoski, Kari K

    2014-08-01

    Endurance training induces cardiovascular and metabolic adaptations, leading to enhanced endurance capacity and exercise performance. Previous human studies have shown contradictory results in functional myocardial vascular adaptations to exercise training, and we hypothesized that this may be related to different degrees of hypertrophy in the trained heart. We studied the interrelationships between peak aerobic power (V˙O2peak), myocardial blood flow (MBF) at rest and during adenosine-induced vasodilation, and parameters of myocardial hypertrophy in endurance-trained (ET, n = 31) and untrained (n = 17) subjects. MBF and myocardial hypertrophy were studied using positron emission tomography and echocardiography, respectively. Both V˙O2peak (P negatively with adenosine-stimulated MBF, but when LV mass was taken into account as a partial correlate, this correlation disappeared. The present results show that increased LV mass in ET subjects explains the reduced hyperemic myocardial perfusion in this subject population and suggests that excessive LV hypertrophy has negative effect on cardiac blood flow capacity.

  3. Variations in peak nasal inspiratory flow among healthy students after using saline solutions.

    Science.gov (United States)

    Olbrich Neto, Jaime; Olbrich, Sandra Regina Leite Rosa; Mori, Natália Leite Rosa; Oliveira, Ana Elisa de; Corrente, José Eduardo

    2016-01-01

    Nasal hygiene with saline solutions has been shown to relieve congestion, reduce the thickening of the mucus and keep nasal cavity clean and moist. Evaluating whether saline solutions improve nasal inspiratory flow among healthy children. Students between 8 and 11 years of age underwent 6 procedures with saline solutions at different concentrations. The peak nasal inspiratory flow was measured before and 30 min after each procedure. Statistical analysis was performed by means of t test, analysis of variance, and Tukey's test, considering p<0.05. We evaluated 124 children at all stages. There were differences on the way a same concentration was used. There was no difference between 0.9% saline solution and 3% saline solution by using a syringe. The 3% saline solution had higher averages of peak nasal inspiratory flow, but it was not significantly higher than the 0.9% saline solution. It is important to offer various options to patients. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  4. An Automated Measurement of Ciliary Beating Frequency using a Combined Optical Flow and Peak Detection.

    Science.gov (United States)

    Kim, Woojae; Han, Tae Hwa; Kim, Hyun Jun; Park, Man Young; Kim, Ku Sang; Park, Rae Woong

    2011-06-01

    The mucociliary transport system is a major defense mechanism of the respiratory tract. The performance of mucous transportation in the nasal cavity can be represented by a ciliary beating frequency (CBF). This study proposes a novel method to measure CBF by using optical flow. To obtain objective estimates of CBF from video images, an automated computer-based image processing technique is developed. This study proposes a new method based on optical flow for image processing and peak detection for signal processing. We compare the measuring accuracy of the method in various combinations of image processing (optical flow versus difference image) and signal processing (fast Fourier transform [FFT] vs. peak detection [PD]). The digital high-speed video method with a manual count of CBF in slow motion video play, is the gold-standard in CBF measurement. We obtained a total of fifty recorded ciliated sinonasal epithelium images to measure CBF from the Department of Otolaryngology. The ciliated sinonasal epithelium images were recorded at 50-100 frames per second using a charge coupled device camera with an inverted microscope at a magnification of ×1,000. The mean square errors and variance for each method were 1.24, 0.84 Hz; 11.8, 2.63 Hz; 3.22, 1.46 Hz; and 3.82, 1.53 Hz for optical flow (OF) + PD, OF + FFT, difference image [DI] + PD, and DI + FFT, respectively. Of the four methods, PD using optical flow showed the best performance for measuring the CBF of nasal mucosa. The proposed method was able to measure CBF more objectively and efficiently than what is currently possible.

  5. Lung function in North American Indian children: reference standards for spirometry, maximal expiratory flow volume curves, and peak expiratory flow.

    Science.gov (United States)

    Wall, M A; Olson, D; Bonn, B A; Creelman, T; Buist, A S

    1982-02-01

    Reference standards of lung function was determined in 176 healthy North American Indian children (94 girls, 82 boys) 7 to 18 yr of age. Spirometry, maximal expiratory flow volume curves, and peak expiratory flow rate were measured using techniques and equipment recommended by the American Thoracic Society. Standing height was found to be an accurate predictor of lung function, and prediction equations for each lung function variable are presented using standing height as the independent variable. Lung volumes and expiratory flow rates in North American Indian children were similar to those previously reported for white and Mexican-American children but were greater than those in black children. In both boys and girls, lung function increased in a curvilinear fashion. Volume-adjusted maximal expiratory flow rates after expiring 50 or 75% of FVC tended to decrease in both sexes as age and height increased. Our maximal expiratory flow volume curve data suggest that as North American Indian children grow, lung volume increases at a slightly faster rate than airway size does.

  6. Effects of dorsal and lateral decubitus on peak expiratory flow in healthy subjects

    Directory of Open Access Journals (Sweden)

    Heloisa H. Gianinis

    2013-10-01

    Full Text Available BACKGROUND: One of the measures of the pulmonary function is the peak expiratory flow (PEF that can be defined as the major flow obtained in an expiratory pressure after a complete inspiration to the level of the total lung capacity. This measure depends on the effort and strength of expiratory muscles, the airway diameter and the lung volume. OBJECTIVE: To compare the results of the peak expiratory flow in healthy male and female obtained in a seated position and dorsal decubitus (DD, right lateral decubitus (RLD and left lateral decubitus (LLD. METHOD: Thirty young subjects with mean age 22.7 years, healthy and non-smokers were included at the study, 15 of male sex. They did spirometry and IPAQ questionnaire to check the normal pulmonary function and physical activity level. The measures of PEF were performed in four positions, being performed 3 measures in which position, in a random order. Statistical analysis was performed according to Student's t test, with significance level set at 5%. RESULTS: There was a difference between the values obtained in sitting position(481±117.1 L/min with DD(453.2±116.3 L/min and RLD (454±112.9 L/min (p<0.05, however, did not find a significant difference between the sitting position and LLD (469±83 L/min. CONCLUSIONS: Body position affects the values of PEF, with decreasing values in DD and RLD. The LLD can be an alternative to optimize the expiratory flow in situations of constraint to the sitting position.

  7. Evaluation of Green Infrastructure on Peak Flow Mitigation Focusing on the Connectivity of Impervious Areas

    Science.gov (United States)

    Seo, Y.; Hwang, J.; Kwon, Y.

    2017-12-01

    The existence of impervious areas is one of the most distinguishing characteristics of urban catchments. It decreases infiltration and increases direct runoff in urban catchments. The recent introduction of green infrastructure in urban catchments for the purpose of sustainable development contributes to the decrease of the directly connected impervious areas (DCIA) by isolating existing impervious areas and consequently, to the flood risk mitigation. This study coupled the width function-based instantaneous hydrograph (WFIUH), which is able to handle the spatial distribution of the impervious areas, with the concept of the DCIA to assess the impact of decreasing DCIA on the shape of direct runoff hydrographs. Using several scenarios for typical green infrastructure and corresponding changes of DCIA in a test catchment, this study evaluated the effect of green infrastructure on the shape of the resulting direct runoff hydrographs and peak flows. The results showed that the changes in the DCIA immediately affects the shape of the direct runoff hydrograph and decreases peak flows depending on spatial implementation scenarios. The quantitative assessment of the spatial distribution of impervious areas and also the changes to the DCIA suggests effective and well-planned green infrastructure can be introduced in urban environments for flood risk management.

  8. Peak expiratory flow rate (PEFR) among Nuclear Fuel Complex (NFC) employees

    International Nuclear Information System (INIS)

    Vijay Rao, J.; Venkaiah, K.; Mohan Rao, N.

    2010-01-01

    At Nuclear Fuel Complex (NFC), employees are exposed to ammonia, hydrofluoric acid, acetone, etc., which are respiratory toxicants and inhalation of these pollutants may produce irritation and obstruction in airways. Due to nature of their occupation, tradesman working in plants are having longer duration of exposure (LDE) and others, such as supervisors, scientific officers, helpers, etc., that occasionally visit plants are having shorter duration of exposure (SDE) to these pollutants. The peak expiratory flow rate (PEFR) is an index to diagnose obstruction in larger airways and this is metered with mini peak flow meter among 835 NFC employees. Using ANOVA test, PEFR value was compared according to age and smoking. The value was compared between LDE and SDE employees according to smoking and duration of employment. The multiple regression equation for prediction of PEFR was developed. Age, smokers and higher duration of LDE employees demonstrated significantly lower PEFR value. In comparison to 10 year duration, 30 and above year duration of employment, LDE employees showed a higher decline in PEFR, that is 95 L (17.6%) and in SDE employees, that is 41L (7.8%). This may be due to longer duration of employment of LD employees smoking prevention and follow up study is suggested. (author)

  9. Sensitivity of peak flow to the change of rainfall temporal pattern due to warmer climate

    Science.gov (United States)

    Fadhel, Sherien; Rico-Ramirez, Miguel Angel; Han, Dawei

    2018-05-01

    The widely used design storms in urban drainage networks has different drawbacks. One of them is that the shape of the rainfall temporal pattern is fixed regardless of climate change. However, previous studies have shown that the temporal pattern may scale with temperature due to climate change, which consequently affects peak flow. Thus, in addition to the scaling of the rainfall volume, the scaling relationship for the rainfall temporal pattern with temperature needs to be investigated by deriving the scaling values for each fraction within storm events, which is lacking in many parts of the world including the UK. Therefore, this study analysed rainfall data from 28 gauges close to the study area with a 15-min resolution as well as the daily temperature data. It was found that, at warmer temperatures, the rainfall temporal pattern becomes less uniform, with more intensive peak rainfall during higher intensive times and weaker rainfall during less intensive times. This is the case for storms with and without seasonal separations. In addition, the scaling values for both the rainfall volume and the rainfall fractions (i.e. each segment of rainfall temporal pattern) for the summer season were found to be higher than the corresponding results for the winter season. Applying the derived scaling values for the temporal pattern of the summer season in a hydrodynamic sewer network model produced high percentage change of peak flow between the current and future climate. This study on the scaling of rainfall fractions is the first in the UK, and its findings are of importance to modellers and designers of sewer systems because it can provide more robust scenarios for flooding mitigation in urban areas.

  10. Replication of Annual Cycles in Mn in Hudson River Cores: Mn Peaks During High Water Flow

    Science.gov (United States)

    Abbott, D. H.; Hutson, D.; Marrero, A. M.; Block, K. A.; Chang, C.; Cai, Y.

    2017-12-01

    Using the results from an ITRAX, XRF scanner, we previously reported apparent annual cycles in Mn in a single, high sedimentation rate Hudson River core, LWB1-8, taken off Yonkers, NY (Carlson et al., 2016). We replicated these results in three more high sedimentation rate cores and found stratigraphic markers that verify our inferences about the annual nature of the Mn cycles. The three new cores are LWB4-5 taken off Peekskill, NY, and LWB3-44 and LWB3-25, both taken in Haverstraw Bay. The cores are from water depths of 7-9 meters and all have high magnetic susceptibilities (typically > 30 cgs units) in their upper 1 to 2 meters. The high susceptibilities are primarily produced by magnetite from modern industrial combustion. One core, LWB1-8, has reconnaissance Cs dates that verify the annual nature of the cycles. More Cs dates are expected before the meeting. We developed several new methods of verifying the annual nature of our layer counts. The first is looking at the grain size distribution and age of layers with unusually high Mn peaks. Peaks in Si, Ni and Ti and peaks in percentage of coarse material typically accompany the peaks in Mn. Some are visible as yellow sandy layers. The five highest peaks in Mn in LWB1-8 have layer counted ages that correspond (within 1 year in the top meter and within 2 years in the bottom meter) to 1996, 1948, 1913, 1857 and 1790. The latter three events are the three largest historical spring freshets on the Hudson. 1996 is a year of unusually high flow rate during the spring freshet. Based on our work and previous work on Mn cycling in rivers, we infer that the peaks in Mn are produced by extreme erosional events that erode sediment and release pore water Mn into the water column. The other methods of testing our chronology involve marine storms that increase Ca and Sr and a search for fragments of the Peekskill meteorite that fell in October 1992. More information on the latter will be available by the meeting.

  11. Hand grip strength and maximum peak expiratory flow: determinants of bone mineral density of adolescent students.

    Science.gov (United States)

    Cossio-Bolaños, Marco; Lee-Andruske, Cynthia; de Arruda, Miguel; Luarte-Rocha, Cristian; Almonacid-Fierro, Alejandro; Gómez-Campos, Rossana

    2018-03-02

    Maintaining and building healthy bones during the lifetime requires a complicated interaction between a number of physiological and lifestyle factors. Our goal of this study was to analyze the association between hand grip strength and the maximum peak expiratory flow with bone mineral density and content in adolescent students. The research team studied 1427 adolescent students of both sexes (750 males and 677 females) between the ages of 11.0 and 18.9 years in the Maule Region of Talca (Chile). Weight, standing height, sitting height, hand grip strength (HGS), and maximum peak expiratory flow (PEF) were measured. Furthermore, bone mineral density (BMD) and total body bone mineral content (BMC) were determined by using the Dual-Energy X-Ray Absorptiometry (DXA). Hand grip strength and PEF were categorized in tertiles (lowest, middle, and highest). Linear regression was performed in steps to analyze the relationship between the variables. Differences between categories were determined through ANOVA. In males, the hand grip strength explained 18-19% of the BMD and 20-23% of the BMC. For the females, the percentage of variation occurred between 12 and 13% of the BMD and 17-18% of the BMC. The variation of PEF for the males was observed as 33% of the BMD and 36% of the BMC. For the females, both the BMD and BMC showed a variation of 19%. The HGS and PEF were divided into three categories (lowest, middle, and highest). In both cases, significant differences occurred in bone density health between the three categories. In conclusion, the HGS and the PEF related positively to the bone density health of both sexes of adolescent students. The adolescents with poor values for hand grip strength and expiratory flow showed reduced values of BMD and BMC for the total body. Furthermore, the PEF had a greater influence on bone density health with respect to the HGS of the adolescents of both sexes.

  12. Remediation scenarios for attenuating peak flows and reducing sediment transport in Fountain Creek, Colorado, 2013

    Science.gov (United States)

    Kohn, Michael S.; Fulton, John W.; Williams, Cory A.; Stogner, Sr., Robert W.

    2014-01-01

    The U.S. Geological Survey (USGS) in cooperation with the Fountain Creek Watershed, Flood Control and Greenway District assessed remediation scenarios to attenuate peak flows and reduce sediment loads in the Fountain Creek watershed. To evaluate these strategies, the U.S. Army Corps of Engineers Hydrologic Engineering Center (HEC) hydrologic and hydraulic models were employed. The U.S. Army Corps of Engineers modeling system HEC-HMS (Hydrologic Modeling System) version 3.5 was used to simulate runoff in the Fountain Creek watershed, Colorado, associated with storms of varying magnitude and duration. Rain-gage precipitation data and radar-based precipitation data from the April 28–30, 1999, and September 14–15, 2011, storm events were used in the calibration process for the HEC-HMS model. The curve number and lag time for each subwatershed and Manning's roughness coefficients for each channel reach were adjusted within an acceptable range so that the simulated and measured streamflow hydrographs for each of the 12 USGS streamgages approximated each other. The U.S. Army Corps of Engineers modeling system HEC-RAS (River Analysis System) versions 4.1 and 4.2 were used to simulate streamflow and sediment transport, respectively, for the Fountain Creek watershed generated by a particular storm event. Data from 15 USGS streamgages were used for model calibration and 7 of those USGS streamgages were used for model validation. The calibration process consisted of comparing the simulated water-surface elevations and the cross-section-averaged velocities from the model with those surveyed in the field at the cross section at the corresponding 15 and 7 streamgages, respectively. The final Manning’s roughness coefficients were adjusted between –30 and 30 percent at the 15 calibration streamgages from the original left, right, and channel-averaged Manning's roughness coefficients upon completion of calibration. The U.S. Army Corps of Engineers modeling system HEC

  13. Peak flow as predictor of overall mortality in asthma and chronic obstructive pulmonary disease

    DEFF Research Database (Denmark)

    Hansen, Ejvind Frausing; Vestbo, Jørgen; Phanareth, K

    2001-01-01

    Lung function is a strong predictor of overall mortality in asthma and chronic obstructive pulmonary disease (COPD). FEV1 is considered to be the "gold standard," whereas peak expiratory flow (PEF) is mostly used in absence of FEV1 measurements. We compared the predictive power of PEF and FEV1......, measured after maximal bronchodilation, which included a short course of oral corticosteroids. The study population comprised 491 asthmatics and 1,095 subjects with COPD. Pulmonary function tests were performed between 1983 and 1988, and survival data were obtained by September 1997, when 127 asthmatics...... reflecting different components of COPD, i.e., chronic bronchitis, small airways disease, and emphysema. Furthermore, extrapulmonary components such as muscle mass and general "vigour" probably affect PEF to a greater extent than they affect FEV1....

  14. Influence Of Number Of Pregnancies In Peak Expiratory Flow And Body Composition Of Pregnant Women

    Directory of Open Access Journals (Sweden)

    Andrea Carla Brandao da Costa Santos

    2017-06-01

    Full Text Available Objectives: to describe and compare the mean values of the body composition and the peak expiratory flow (PEF in primigravidae and multigravidae and, to determine its correlation with obstetric, anthropometric and body composition variables. Method: it was performed a cross-sectional study of 120 healthy pregnant women at low risk, including 77 primigravidae and 43 multigravidae. The PEF was measured by spirometry and the body composition by multisegmental electrical impedance. The unpaired t test was used to compare the groups and the Pearson correlation test was used to determine the association between PEF and independent variables. A multiple linear regression was used to estimate the relationship between the dependent variable, the PEF and the independent variables. Results: the body composition variables in multigravidae women showed higher values compared to the primigravidae, being statistically significant, except for fat mass. In primigravidae, the PEF was correlated significantly with maternal age and height. In multigravidae, the PEF was correlated with maternal age, height, pre-pregnancy and current weight, total body water, extracellular water, fat mass, lean mass and fat-free mass. A Multiple linear regression analysis showed that, in primigravidae, height and maternal age were associated with PEF, being responsible for explaining 14.5% of its variability. The current weight and the maternal age explained 42.3% of peak flow variability in multigravidae. Conclusion: The PEF seemed to be influenced by the number of pregnancies. Changes were observed in relation to the body composition, as it was evidenced in correlation with the PEF in multigravidae women. Keywords: Pregnancy. Spirometry. Weight gain.

  15. A study of diurnal variation in peak expiratory flow rates in healthy adult female subjects in South India

    Directory of Open Access Journals (Sweden)

    Jenny Jayapal

    2014-01-01

    Full Text Available Background: Peak Expiratory Flow Rate (PEFR reflects the strength and condition of respiratory muscles and the degree of airflow limitation in large airways. PEFR shows hour to hour variation that follows a specific pattern in asthmatics and healthy individuals. Adequate data is not available for the diurnal variation in normal individuals who are students in professional courses and had a sedentary life style. Hence, this study was undertaken to study the diurnal variation in peak expiratory flow rates in healthy adult female subjects in South India. Materials and Methods: Peak expiratory flow rate was recorded in 50 adult healthy female students aged 18-23 years and studying in professional courses. Mini Wright′s peak flow meter was used to measure the peak expiratory flow rate. PEFR were recorded at 7-8 a.m., 10-11 a.m., 1-2 p.m., 4-5 p.m., and 7-8 p.m. for two consecutive days. Results: On analysis of PEFR records of individual subjects, it was seen that there was an overall dip in the morning at 7-8 h PEFR, which increased in the daytime, peaking in the afternoon at 1-2 p.m. and eventually decreased in the night. Subjects did not show the peak PEFR values at the same time point, 10% of subjects had a rise in PEFR in the early morning, afternoon (1-2 p.m. peak was observed in 48% subjects and evening (4-5 p.m. peak was observed in 16% subjects. 14% subjects showed a peak in the night time (7-8 p.m. PEFR values. Conclusion: This study provided the preliminary reference data of diurnal variation of peak expiratory flow rate in healthy adults. Since, there is a variation in the peak expiratory flow rate recorded during different time points of the day; hence, to compare the PEFR between individuals it is advisable to record the PEFR at the same time point.

  16. Investigating the impact of land cover change on peak river flow in UK upland peat catchments, based on modelled scenarios

    Science.gov (United States)

    Gao, Jihui; Holden, Joseph; Kirkby, Mike

    2014-05-01

    Changes to land cover can influence the velocity of overland flow. In headwater peatlands, saturation means that overland flow is a dominant source of runoff, particularly during heavy rainfall events. Human modifications in headwater peatlands may include removal of vegetation (e.g. by erosion processes, fire, pollution, overgrazing) or pro-active revegetation of peat with sedges such as Eriophorum or mosses such as Sphagnum. How these modifications affect the river flow, and in particular the flood peak, in headwater peatlands is a key problem for land management. In particular, the impact of the spatial distribution of land cover change (e.g. different locations and sizes of land cover change area) on river flow is not clear. In this presentation a new fully distributed version of TOPMODEL, which represents the effects of distributed land cover change on river discharge, was employed to investigate land cover change impacts in three UK upland peat catchments (Trout Beck in the North Pennines, the Wye in mid-Wales and the East Dart in southwest England). Land cover scenarios with three typical land covers (i.e. Eriophorum, Sphagnum and bare peat) having different surface roughness in upland peatlands were designed for these catchments to investigate land cover impacts on river flow through simulation runs of the distributed model. As a result of hypothesis testing three land cover principles emerged from the work as follows: Principle (1): Well vegetated buffer strips are important for reducing flow peaks. A wider bare peat strip nearer to the river channel gives a higher flow peak and reduces the delay to peak; conversely, a wider buffer strip with higher density vegetation (e.g. Sphagnum) leads to a lower peak and postpones the peak. In both cases, a narrower buffer strip surrounding upstream and downstream channels has a greater effect than a thicker buffer strip just based around the downstream river network. Principle (2): When the area of change is equal

  17. The effects of smokeless cookstoves on peak expiratory flow rates in rural Honduras.

    Science.gov (United States)

    Rennert, W P; Porras Blanco, R M; Muniz, G B

    2015-09-01

    The use of biomass fuel for cooking in traditional cookstove designs negatively affects respiratory health of communities in developing countries. Indoor pollution affects particularly women and children, who are participating in food preparation. The effects of smokeless cookstove designs on indoor pollution are well documented, but few studies exist to assess the effects of improved stove designs on the respiratory health of community members. This study uses peak expiratory flow rate (PEFR) measurements in a before-and-after format to assess respiratory function of inhabitants of all 30 houses of Buenas Noches in central Honduras. PEFRs are measured before and 6 months after the installation of Justa stoves in people's homes. Health behaviors, respiratory symptoms and fire wood use are evaluated in a door-to-door survey format. A total of 137 eligible women and children between 6 and 14 years participated in the study. PEFR improved by 9.9-18.5% (P < 0.001) depending on the participants' exposure to indoor pollution. Health complaints like cough and behaviors like clinic visits did not change with the introduction of smokeless cookstove technology. Smokeless stoves improve respiratory health in an environment of high levels of indoor pollution. © The Author 2014. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. The longitudinal relationship of work stress with peak expiratory flow: a cohort study.

    Science.gov (United States)

    Loerbroks, Adrian; Karrasch, Stefan; Lunau, Thorsten

    2017-10-01

    Research has suggested that psychological stress is associated with reduced lung function and with the development of respiratory disease. Among the major potential sources of stress in adulthood are working conditions. We aimed to examine the relationship of work stress with lung function. We drew on 4-year prospective data from the Survey of Health, Ageing and Retirement in Europe. The analyzed sample comprised 2627 workers aged 50 years or older who were anamnestically free of respiratory disease. Work stress at baseline was operationalized by abbreviated instruments measuring the well-established effort-reward imbalance model (seven items) and the control component of the job-demand control (two items). Peak expiratory flow (PEF) was determined at baseline and at follow-up. Continuous and categorized (i.e., by the tertile) work stress variables were employed in multivariable linear regression models to predict PEF change. Work stress did not show statistically significant associations with PEF change. For instance, the unstandardized regression coefficient for PEF decline according to high versus low effort-reward imbalance was -1.41 (95% confidence interval = -3.75, 0.94). Our study is the first to examine prospective relationships between work stress and PEF. Overall, we did not observe meaningful associations. Future studies should consider a broader spectrum of spirometric parameters and should expand research to younger and possibly less-selected working populations (i.e., aged <50 years).

  19. Can Preoperative Peak Expiratory Flow Predict Postoperative Pulmonary Complications in Lung Cancer Patients Undergoing Lobectomy?

    Directory of Open Access Journals (Sweden)

    Kun ZHOU

    2017-09-01

    Full Text Available Background and objective Postoperative pulmonary complications (PPCs, especially postoperative pneumonia (POP, directly affect the rapid recovery of lung cancer patients after surgery. Peak expiratory flow (PEF can reflect airway patency and cough efficiency. Moreover, cough impairment may lead to accumulation of pulmonary secretions which can increase the risk of PPCs. The aim of this study is to investigate the effect of preoperative PEF on PPCs in patients with lung cancer. Methods Retrospective research was conducted on 433 lung cancer patients who underwent lobectomy at the West China Hospital of Sichuan University from January 2014 to December 2015. The associations between preoperative PEF and PPCs were analyzed based on patients’ basic characteristics and clinical data in hospital. Results Preoperative PEF value in PPCs group (280.93±88.99 L/min was significantly lower than that in non-PPCs group (358.38±93.69 L/min (P320 L/min group (9.4%(P<0.001. Conclusion Preoperative PEF and PPCs are correlated, and PEF may be used as a predictor of PPCs.

  20. Calculation of the heat flow peak in case of local defect of the fuel plate of a nuclear reactor

    International Nuclear Information System (INIS)

    Fabrega, Serge

    1965-11-01

    The author reports the calculation of the local thermal flow which exits a fuel plate in a nuclear reactor, where a fabrication defect creates a much localized peak of the power density released in the plate. He first reports the development of the problem equations: hypotheses and data, equation elaboration, simplification and resolution. He presents the results of a numeric application to actual cases, and describes how the conduction in the sheath is taken into account (study of the influence of peak width and shape), and gives a synthetic presentation of the formula for the approximate calculation of the heat flow in case of local defect [fr

  1. Conversion of Aircraft Dual-flow Turbojet into Peak Power Plant

    Directory of Open Access Journals (Sweden)

    G. A. Shafikov

    2017-01-01

    Full Text Available The paper is aimed at considering the aircraft engine conversion into peak or short-used energy unit, which is relevant for the task of developing the northern regions of the Russian Federation. The three-shaft turbojet engine with a twelve-stage compressor and a four-stage turbine is adopted as an aircraft engine under consideration. The afterburner with a block of jet nozzles is removed from the gas generator module, and a heating chamber is set at the outlet of the by-pass duct to raise electric power of engine and not complicate the construction by the presence of a mixing chamber. In addition, the heating chamber serves to equalize the total pressure and flow temperature in the section before the free turbine and allows the use of a short adapter between the gas generator module and the free turbine, which reduces the loss of total pressure. Then a free turbine and a diffuser with an exhaust device are installed. The output shaft of the power turbine is connected by means of a coupling to an alternating current (a. c. generator or other special load.To find the parameters of the plant, a calculation was made in which the initial data were taken, namely a gas temperature in front of the turbine of 1530 K (the gas temperature in front of the turbine is reduced by 100 K in order to prolong the engine life; therefore, the gas temperature before the turbine was 1630 K; air flow of 364 kg/s; bypass ratio of 1.36 (the ratio of the air flow passing through the bypass duct to the air flow entering the core. As a result, it consumes 0.296 kg / (kWh (fuel-aviation kerosene and a power capacity of 78.5 MW. For the received value of capacity the ТЗФП-80-2У3 a. c. electric generator has been chosen as the load. As a result, the power plant, equipped with a converted engine and electric generator, has an electric power of 77.3 MW and an efficiency of 27.8%.To assess the effect of introduced preheating chamber on the parameters of the gas turbine

  2. Difficulty in obtaining peak expiratory flow measurements in children with acute asthma.

    Science.gov (United States)

    Gorelick, Marc H; Stevens, Molly W; Schultz, Theresa; Scribano, Philip V

    2004-01-01

    To determine the frequency with which children >or=6 years with acute asthma can perform peak expiratory flow rate measurements (PEFR) in an emergency department (ED). Data were obtained from a prospective cohort study of children with acute asthma. All children (age 2-18 years old) treated in an urban pediatric ED for an acute exacerbation during randomly selected days over a 12-month period were prospectively evaluated. According to treatment protocols, PEFR was to be measured in all children age 6 years and older before therapy and after each treatment with inhaled bronchodilators. Registered respiratory therapists obtained PEFR and evaluated whether patients were able to perform the maneuver adequately. Four hundred and fifty-six children, 6 to 18 years old (median 10 years), were enrolled; 291 (64%) had PEFR measured at least once. Of those in whom PEFR was attempted at least once, only 190 (65%) were able to perform adequately. At the start of therapy, 54% (142/262) were able to perform PEFR. Of the 120 who were unable to perform initially, 76 had another attempt at the end of the ED treatment, and 55 (72%) were still unable to perform. A total of 149 patients had attempts at PEFR both at the start and end of treatment, of these, only 71 (48%) provided valid information on both attempts. Patients unable to perform PEFR were younger (mean +/- SD = 8.7 +/- 2.8 years) than those who were able to perform successfully (11.2 +/- 3.2 years) and those with no attempts (10.0 +/- 3.4 years). Children admitted to the hospital were more likely to be unable to perform PEFR (58/126 = 46%) than those discharged from the ED (43/330 = 13%, P < 0.0001). Adequate PEFR measurements are difficult to obtain in children with acute asthma. Treatment and research protocols cannot rely exclusively on PEFR for evaluation of severity.

  3. Case Study: On Objective Functions for the Peak Flow Calibration and for the Representative Parameter Estimation of the Basin

    Directory of Open Access Journals (Sweden)

    Jungwook Kim

    2018-05-01

    Full Text Available The objective function is usually used for verification of the optimization process between observed and simulated flows for the parameter estimation of rainfall–runoff model. However, it does not focus on peak flow and on representative parameter for various rain storm events of the basin, but it can estimate the optimal parameters by minimizing the overall error of observed and simulated flows. Therefore, the aim of this study is to suggest the objective functions that can fit peak flow in hydrograph and estimate the representative parameter of the basin for the events. The Streamflow Synthesis And Reservoir Regulation (SSARR model was employed to perform flood runoff simulation for the Mihocheon stream basin in Geum River, Korea. Optimization was conducted using three calibration methods: genetic algorithm, pattern search, and the Shuffled Complex Evolution method developed at the University of Arizona (SCE-UA. Two objective functions of the Sum of Squared of Residual (SSR and the Weighted Sum of Squared of Residual (WSSR suggested in this study for peak flow optimization were applied. Since the parameters estimated using a single rain storm event do not represent the parameters for various rain storms in the basin, we used the representative objective function that can minimize the sum of objective functions of the events. Six rain storm events were used for the parameter estimation. Four events were used for the calibration and the other two for validation; then, the results by SSR and WSSR were compared. Flow runoff simulation was carried out based on the proposed objective functions, and the objective function of WSSR was found to be more useful than that of SSR in the simulation of peak flow runoff. Representative parameters that minimize the objective function for each of the four rain storm events were estimated. The calibrated observed and simulated flow runoff hydrographs obtained from applying the estimated representative

  4. Impact of Wet-Weather Peak Flow Blending on Disinfection and Treatment: A Case Study at Three Wastewater Treatment Plants

    Science.gov (United States)

    This research project was administered by the EPA Office of Research and Development and funded by Office of Water; Office of Policy, Economics and Innovation; and Office of Research and Development. Blending is the practice of diverting a part of peak wet-weather flows at wa...

  5. RELATIONSHIP OF AIRWAY HYPERRESPONSIVENESS TO RESPIRATORY SYMPTOMS AND DIURNAL PEAK FLOW VARIATION IN PATIENTS WITH OBSTRUCTIVE LUNG-DISEASE

    NARCIS (Netherlands)

    BRAND, PLP; POSTMA, DS; KERSTJENS, HAM; KOETER, GH

    This study reports on the relationship of airway hyperresponsiveness (AH) with respiratory symptoms and diurnal peak flow expiratory (PEF) variation in 221 hyperresponsive patients with moderately severe airways obstruction. The disease was in a stable phase in all patients. Closely adhering to the

  6. Comparison of peak expiratory flow rate and lipid profile in asymptomatic smokers and non-smokers

    International Nuclear Information System (INIS)

    Fatima, F.; Abbasi, M.A.; Jadoon, J.; Sohail, M.; Shah, J.; Afridi, U.; Noor, M.M.

    2015-01-01

    Tobacco is the major risk factor for chronic obstructive airway disease (COAD), other pulmonary diseases, cancer, cardiovascular and cerebrovascular diseases. The objective of study was to determine the mean Peak Expiratory Flow Rate (PEFR) and serum lipid profile in apparently healthy male smokers and non-smokers. Methods: This cross-sectional study was conducted in Ayub Teaching Hospital, Abbottabad from 15th December, 2009 to 15th June, 2010. Apparently healthy smokers and non-smokers from population coming to Hospital as attendants of the patients or as employees of the hospital were inducted in the study. PEFR and lipid profile of all the subjects was accessed. Results: There were total of 300 male subjects, 150 smokers and 150 non-smokers. The mean age of study subjects was 26.60 ± 5.5 years. The mean PEFR of smokers was 450.62l/min and that of non-smokers was 494.81 L/min, the difference being statistically significant (p-value <0.05).The mean total cholesterol of smokers is 5.30 ± 0.86 mmol/l and it was 3.84 ± 0.54 mmol/l in non-smokers. Mean serum Triacyl Glycerols (TAGs) and Low Density Lipoproteins (LDL) cholesterol of smokers was 2.04 ± 0.38 and 3.5 ± 0.83 mmol/l whereas it was 1.44 ± 0.52 and 2.02 ± 0.66 mmol/l in non-smokers. Mean High Density Lipo-protein (HDL) of smokers was 0.86 ± 0.30 mmol/l and of non-smokers is 1.20 ± 0.41 mmo/l. There was statistically significant difference between serum lipid profile of smokers and non-smokers (p<0.05). the mean serum Total Cholesterol (TC), TAGs and LDL were significantly higher in smokers as compared to non-smokers. However HDL was significantly lower in smokers in comparison to non-smokers. Conclusion: There was statistically significant difference between PEFR of smokers and non-smokers. Higher and significant mean values of TC, TAG and LDL-C was observed in smokers as compared to non-smokers. (author)

  7. Storing of Extracts in Polypropylene Microcentrifuge Tubes Yields Contaminant Peak During Ultra-flow Liquid Chromatographic Analysis.

    Science.gov (United States)

    Kshirsagar, Parthraj R; Hegde, Harsha; Pai, Sandeep R

    2016-05-01

    This study was designed to understand the effect of storage in polypropylene microcentrifuge tubes and glass vials during ultra-flow liquid chromatographic (UFLC) analysis. One ml of methanol was placed in polypropylene microcentrifuge tubes (PP material, Autoclavable) and glass vials (Borosilicate) separately for 1, 2, 4, 8, 10, 20, 40, and 80 days intervals stored at -4°C. Contaminant peak was detected in methanol stored in polypropylene microcentrifuge tubes using UFLC analysis. The contaminant peak detected was prominent, sharp detectable at 9.176 ± 0.138 min on a Waters 250-4.6 mm, 4 μ, Nova-Pak C18 column with mobile phase consisting of methanol:water (70:30). It was evident from the study that long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peak. Further, this may mislead in future reporting an unnatural compound by researchers. Long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peakContamination peak with higher area under the curve (609993) was obtained in ultra-flow liquid chromatographic run for methanol stored in PP microcentrifuge tubesContamination peak was detected at retention time 9.113 min with a lambda max of 220.38 nm and 300 mAU intensity on the given chromatographic conditionsGlass vials serve better option over PP microcentrifuge tubes for storing biological samples. Abbreviations used: UFLC: Ultra Flow Liquid Chromatography; LC: Liquid Chromatography; MS: Mass spectrometry; AUC: Area Under Curve.

  8. Prediction of peak response values of structures with and without TMD subjected to random pedestrian flows

    Science.gov (United States)

    Lievens, Klaus; Van Nimmen, Katrien; Lombaert, Geert; De Roeck, Guido; Van den Broeck, Peter

    2016-09-01

    In civil engineering and architecture, the availability of high strength materials and advanced calculation techniques enables the construction of slender footbridges, generally highly sensitive to human-induced excitation. Due to the inherent random character of the human-induced walking load, variability on the pedestrian characteristics must be considered in the response simulation. To assess the vibration serviceability of the footbridge, the statistics of the stochastic dynamic response are evaluated by considering the instantaneous peak responses in a time range. Therefore, a large number of time windows are needed to calculate the mean value and standard deviation of the instantaneous peak values. An alternative method to evaluate the statistics is based on the standard deviation of the response and a characteristic frequency as proposed in wind engineering applications. In this paper, the accuracy of this method is evaluated for human-induced vibrations. The methods are first compared for a group of pedestrians crossing a lightly damped footbridge. Small differences of the instantaneous peak value were found by the method using second order statistics. Afterwards, a TMD tuned to reduce the peak acceleration to a comfort value, was added to the structure. The comparison between both methods in made and the accuracy is verified. It is found that the TMD parameters are tuned sufficiently and good agreements between the two methods are found for the estimation of the instantaneous peak response for a strongly damped structure.

  9. Suspended particle and pathogen peak discharge buffering by a surface-flow constructed wetland

    NARCIS (Netherlands)

    Mulling, B.T.M.; van den Boomen, R.M.; van der Geest, H.G.; Kappelhof, J.W.N.M.; Admiraal, W.

    2013-01-01

    Constructed wetlands (CWs) have been shown to improve the water quality of treated wastewater. The capacity of CWs to reduce nutrients, pathogens and organic matter and restore oxygen regime under normal operating conditions cannot be extrapolated to periods of incidental peak discharges. The

  10. An adaptive model for vanadium redox flow battery and its application for online peak power estimation

    Science.gov (United States)

    Wei, Zhongbao; Meng, Shujuan; Tseng, King Jet; Lim, Tuti Mariana; Soong, Boon Hee; Skyllas-Kazacos, Maria

    2017-03-01

    An accurate battery model is the prerequisite for reliable state estimate of vanadium redox battery (VRB). As the battery model parameters are time varying with operating condition variation and battery aging, the common methods where model parameters are empirical or prescribed offline lacks accuracy and robustness. To address this issue, this paper proposes to use an online adaptive battery model to reproduce the VRB dynamics accurately. The model parameters are online identified with both the recursive least squares (RLS) and the extended Kalman filter (EKF). Performance comparison shows that the RLS is superior with respect to the modeling accuracy, convergence property, and computational complexity. Based on the online identified battery model, an adaptive peak power estimator which incorporates the constraints of voltage limit, SOC limit and design limit of current is proposed to fully exploit the potential of the VRB. Experiments are conducted on a lab-scale VRB system and the proposed peak power estimator is verified with a specifically designed "two-step verification" method. It is shown that different constraints dominate the allowable peak power at different stages of cycling. The influence of prediction time horizon selection on the peak power is also analyzed.

  11. Storing of Extracts in Polypropylene Microcentrifuge Tubes Yields Contaminant Peak During Ultra-flow Liquid Chromatographic Analysis

    OpenAIRE

    Kshirsagar, Parthraj R.; Hegde, Harsha; Pai, Sandeep R.

    2016-01-01

    Background and Aim: This study was designed to understand the effect of storage in polypropylene microcentrifuge tubes and glass vials during ultra-flow liquid chromatographic (UFLC) analysis. Materials and Methods: One ml of methanol was placed in polypropylene microcentrifuge tubes (PP material, Autoclavable) and glass vials (Borosilicate) separately for 1, 2, 4, 8, 10, 20, 40, and 80 days intervals stored at ?4?C. Results: Contaminant peak was detected in methanol stored in polypropylene m...

  12. Hydrological model calibration for derived flood frequency analysis using stochastic rainfall and probability distributions of peak flows

    Science.gov (United States)

    Haberlandt, U.; Radtke, I.

    2014-01-01

    Derived flood frequency analysis allows the estimation of design floods with hydrological modeling for poorly observed basins considering change and taking into account flood protection measures. There are several possible choices regarding precipitation input, discharge output and consequently the calibration of the model. The objective of this study is to compare different calibration strategies for a hydrological model considering various types of rainfall input and runoff output data sets and to propose the most suitable approach. Event based and continuous, observed hourly rainfall data as well as disaggregated daily rainfall and stochastically generated hourly rainfall data are used as input for the model. As output, short hourly and longer daily continuous flow time series as well as probability distributions of annual maximum peak flow series are employed. The performance of the strategies is evaluated using the obtained different model parameter sets for continuous simulation of discharge in an independent validation period and by comparing the model derived flood frequency distributions with the observed one. The investigations are carried out for three mesoscale catchments in northern Germany with the hydrological model HEC-HMS (Hydrologic Engineering Center's Hydrologic Modeling System). The results show that (I) the same type of precipitation input data should be used for calibration and application of the hydrological model, (II) a model calibrated using a small sample of extreme values works quite well for the simulation of continuous time series with moderate length but not vice versa, and (III) the best performance with small uncertainty is obtained when stochastic precipitation data and the observed probability distribution of peak flows are used for model calibration. This outcome suggests to calibrate a hydrological model directly on probability distributions of observed peak flows using stochastic rainfall as input if its purpose is the

  13. Impact of urban WWTP and CSO fluxes on river peak flow extremes under current and future climate conditions.

    Science.gov (United States)

    Keupers, Ingrid; Willems, Patrick

    2013-01-01

    The impact of urban water fluxes on the river system outflow of the Grote Nete catchment (Belgium) was studied. First the impact of the Waste Water Treatment Plant (WWTP) and the Combined Sewer Overflow (CSO) outflows on the river system for the current climatic conditions was determined by simulating the urban fluxes as point sources in a detailed, hydrodynamic river model. Comparison was made of the simulation results on peak flow extremes with and without the urban point sources. In a second step, the impact of climate change scenarios on the urban fluxes and the consequent impacts on the river flow extremes were studied. It is shown that the change in the 10-year return period hourly peak flow discharge due to climate change (-14% to +45%) was in the same order of magnitude as the change due to the urban fluxes (+5%) in current climate conditions. Different climate change scenarios do not change the impact of the urban fluxes much except for the climate scenario that involves a strong increase in rainfall extremes in summer. This scenario leads to a strong increase of the impact of the urban fluxes on the river system.

  14. Development of flood regressions and climate change scenarios to explore estimates of future peak flows

    Science.gov (United States)

    Burns, Douglas A.; Smith, Martyn J.; Freehafer, Douglas A.

    2015-12-31

    A new Web-based application, titled “Application of Flood Regressions and Climate Change Scenarios To Explore Estimates of Future Peak Flows”, has been developed by the U.S. Geological Survey, in cooperation with the New York State Department of Transportation, that allows a user to apply a set of regression equations to estimate the magnitude of future floods for any stream or river in New York State (exclusive of Long Island) and the Lake Champlain Basin in Vermont. The regression equations that are the basis of the current application were developed in previous investigations by the U.S. Geological Survey (USGS) and are described at the USGS StreamStats Web sites for New York (http://water.usgs.gov/osw/streamstats/new_york.html) and Vermont (http://water.usgs.gov/osw/streamstats/Vermont.html). These regression equations include several fixed landscape metrics that quantify aspects of watershed geomorphology, basin size, and land cover as well as a climate variable—either annual precipitation or annual runoff.

  15. Model Related Estimates of time dependent quantiles of peak flows - case study for selected catchments in Poland

    Science.gov (United States)

    Strupczewski, Witold G.; Bogdanowich, Ewa; Debele, Sisay

    2016-04-01

    Under Polish climate conditions the series of Annual Maxima (AM) flows are usually a mixture of peak flows of thaw- and rainfall- originated floods. The northern, lowland regions are dominated by snowmelt floods whilst in mountainous regions the proportion of rainfall floods is predominant. In many stations the majority of AM can be of snowmelt origin, but the greatest peak flows come from rainfall floods or vice versa. In a warming climate, precipitation is less likely to occur as snowfall. A shift from a snow- towards a rain-dominated regime results in a decreasing trend in mean and standard deviations of winter peak flows whilst rainfall floods do not exhibit any trace of non-stationarity. That is why a simple form of trends (i.e. linear trends) are more difficult to identify in AM time-series than in Seasonal Maxima (SM), usually winter season time-series. Hence it is recommended to analyse trends in SM, where a trend in standard deviation strongly influences the time -dependent upper quantiles. The uncertainty associated with the extrapolation of the trend makes it necessary to apply a relationship for trend which has time derivative tending to zero, e.g. we can assume a new climate equilibrium epoch approaching, or a time horizon is limited by the validity of the trend model. For both winter and summer SM time series, at least three distributions functions with trend model in the location, scale and shape parameters are estimated by means of the GAMLSS package using the ML-techniques. The resulting trend estimates in mean and standard deviation are mutually compared to the observed trends. Then, using AIC measures as weights, a multi-model distribution is constructed for each of two seasons separately. Further, assuming a mutual independence of the seasonal maxima, an AM model with time-dependent parameters can be obtained. The use of a multi-model approach can alleviate the effects of different and often contradictory trends obtained by using and identifying

  16. Error of the modelled peak flow of the hydraulically reconstructed 1907 flood of the Ebro River in Xerta (NE Iberian Peninsula)

    Science.gov (United States)

    Lluís Ruiz-Bellet, Josep; Castelltort, Xavier; Carles Balasch, J.; Tuset, Jordi

    2016-04-01

    The estimation of the uncertainty of the results of the hydraulic modelling has been deeply analysed, but no clear methodological procedures as to its determination have been formulated when applied to historical hydrology. The main objective of this study was to calculate the uncertainty of the resulting peak flow of a typical historical flood reconstruction. The secondary objective was to identify the input variables that influenced the result the most and their contribution to peak flow total error. The uncertainty of 21-23 October 1907 flood of the Ebro River (NE Iberian Peninsula) in the town of Xerta (83,000 km2) was calculated with a series of local sensitivity analyses of the main variables affecting the resulting peak flow. Besides, in order to see to what degree the result depended on the chosen model, the HEC-RAS resulting peak flow was compared to the ones obtained with the 2D model Iber and with Manning's equation. The peak flow of 1907 flood in the Ebro River in Xerta, reconstructed with HEC-RAS, was 11500 m3·s-1 and its total error was ±31%. The most influential input variable over HEC-RAS peak flow results was water height; however, the one that contributed the most to peak flow error was Manning's n, because its uncertainty was far greater than water height's. The main conclusion is that, to ensure the lowest peak flow error, the reliability and precision of the flood mark should be thoroughly assessed. The peak flow was 12000 m3·s-1 when calculated with the 2D model Iber and 11500 m3·s-1 when calculated with the Manning equation.

  17. Estimation of the supplementary axial wall stress generated at peak flow by an arterial stenosis

    International Nuclear Information System (INIS)

    Doriot, Pierre-Andre

    2003-01-01

    Mechanical stresses in arterial walls are known to be implicated in the development of atherosclerosis. While shear stress and circumferential stress have received a lot of attention, axial stress has not. Yet, stenoses can be intuitively expected to produce a supplementary axial stress during flow systole in the region immediately proximal to the constriction cone. In this paper, a model for the estimation of this effect is presented, and ten numerical examples are computed. These examples show that the cyclic increase in axial stress can be quite considerable in severe stenoses (typically 120% or more of the normal stress value). This result is in best agreement with the known mechanical or morphological risk factors of stenosis progression and restenosis (hypertension, elevated pulse pressure, degree of stenosis, stenosis geometry, residual stenosis, etc). The supplementary axial stress generated by a stenosis might create the damages in the endothelium and in the elastic membranes which potentiate the action of the other risk factors (hyperlipidaemia, diabetes, etc). It could thus be an important cause of stenosis progression and of restenosis

  18. Estimation of the supplementary axial wall stress generated at peak flow by an arterial stenosis

    Science.gov (United States)

    Doriot, Pierre-André

    2003-01-01

    Mechanical stresses in arterial walls are known to be implicated in the development of atherosclerosis. While shear stress and circumferential stress have received a lot of attention, axial stress has not. Yet, stenoses can be intuitively expected to produce a supplementary axial stress during flow systole in the region immediately proximal to the constriction cone. In this paper, a model for the estimation of this effect is presented, and ten numerical examples are computed. These examples show that the cyclic increase in axial stress can be quite considerable in severe stenoses (typically 120% or more of the normal stress value). This result is in best agreement with the known mechanical or morphological risk factors of stenosis progression and restenosis (hypertension, elevated pulse pressure, degree of stenosis, stenosis geometry, residual stenosis, etc). The supplementary axial stress generated by a stenosis might create the damages in the endothelium and in the elastic membranes which potentiate the action of the other risk factors (hyperlipidaemia, diabetes, etc). It could thus be an important cause of stenosis progression and of restenosis.

  19. Attribution of Large-Scale Climate Patterns to Seasonal Peak-Flow and Prospects for Prediction Globally

    Science.gov (United States)

    Lee, Donghoon; Ward, Philip; Block, Paul

    2018-02-01

    Flood-related fatalities and impacts on society surpass those from all other natural disasters globally. While the inclusion of large-scale climate drivers in streamflow (or high-flow) prediction has been widely studied, an explicit link to global-scale long-lead prediction is lacking, which can lead to an improved understanding of potential flood propensity. Here we attribute seasonal peak-flow to large-scale climate patterns, including the El Niño Southern Oscillation (ENSO), Pacific Decadal Oscillation (PDO), North Atlantic Oscillation (NAO), and Atlantic Multidecadal Oscillation (AMO), using streamflow station observations and simulations from PCR-GLOBWB, a global-scale hydrologic model. Statistically significantly correlated climate patterns and streamflow autocorrelation are subsequently applied as predictors to build a global-scale season-ahead prediction model, with prediction performance evaluated by the mean squared error skill score (MSESS) and the categorical Gerrity skill score (GSS). Globally, fair-to-good prediction skill (20% ≤ MSESS and 0.2 ≤ GSS) is evident for a number of locations (28% of stations and 29% of land area), most notably in data-poor regions (e.g., West and Central Africa). The persistence of such relevant climate patterns can improve understanding of the propensity for floods at the seasonal scale. The prediction approach developed here lays the groundwork for further improving local-scale seasonal peak-flow prediction by identifying relevant global-scale climate patterns. This is especially attractive for regions with limited observations and or little capacity to develop flood early warning systems.

  20. StreamStats in Oklahoma - Drainage-Basin Characteristics and Peak-Flow Frequency Statistics for Ungaged Streams

    Science.gov (United States)

    Smith, S. Jerrod; Esralew, Rachel A.

    2010-01-01

    drainage-basin outlet for the period 1961-1990, 10-85 channel slope (slope between points located at 10 percent and 85 percent of the longest flow-path length upstream from the outlet), and percent impervious area. The Oklahoma StreamStats application interacts with the National Streamflow Statistics database, which contains the peak-flow regression equations in a previously published report. Fourteen peak-flow (flood) frequency statistics are available for computation in the Oklahoma StreamStats application. These statistics include the peak flow at 2-, 5-, 10-, 25-, 50-, 100-, and 500-year recurrence intervals for rural, unregulated streams; and the peak flow at 2-, 5-, 10-, 25-, 50-, 100-, and 500-year recurrence intervals for rural streams that are regulated by Natural Resources Conservation Service floodwater retarding structures. Basin characteristics and streamflow statistics cannot be computed for locations in playa basins (mostly in the Oklahoma Panhandle) and along main stems of the largest river systems in the state, namely the Arkansas, Canadian, Cimarron, Neosho, Red, and Verdigris Rivers, because parts of the drainage areas extend outside of the processed hydrologic units.

  1. Understand the impacts of wetland restoration on peak flow and baseflow by coupling hydrologic and hydrodynamic models

    Science.gov (United States)

    Gao, H.; Sabo, J. L.

    2016-12-01

    Wetlands as the earth's kidneys provides various ecosystem services, such as absorbing pollutants, purifying freshwater, providing habitats for diverse ecosystems, sustaining species richness and biodiversity. From hydrologic perspective, wetlands can store storm-flood water in flooding seasons and release it afterwards, which will reduce flood peaks and reshape hydrograph. Therefore, as a green infrastructure and natural capital, wetlands provides a competent alternative to manage water resources in a green way, with potential to replace the widely criticized traditional gray infrastructure (i.e. dams and dikes) in certain cases. However, there are few systematic scientific tools to support our decision-making on site selection and allow us to quantitatively investigate the impacts of restored wetlands on hydrological process, not only in local scale but also in the view of entire catchment. In this study, we employed a topographic index, HAND (the Height Above the Nearest Drainage), to support our decision on potential site selection. Subsequently, a hydrological model (VIC, Variable Infiltration Capacity) was coupled with a macro-scale hydrodynamic model (CaMa-Flood, Catchment-Based Macro-scale Floodplain) to simulate the impact of wetland restoration on flood peaks and baseflow. The results demonstrated that topographic information is an essential factor to select wetland restoration location. Different reaches, wetlands area and the change of roughness coefficient should be taken into account while evaluating the impacts of wetland restoration. The simulated results also clearly illustrated that wetland restoration will increase the local storage and decrease the downstream peak flow which is beneficial for flood prevention. However, its impact on baseflow is ambiguous. Theoretically, restored wetlands will increase the baseflow due to the slower release of the stored flood water, but the increase of wetlands area may also increase the actual evaporation

  2. [Modification of expiratory peak flow (EPF) in 14 asthmatic subjects from Benin by short duration exercise training].

    Science.gov (United States)

    Lawani, M M; Hounkpatin, S; Akplogan, B

    2006-01-01

    Asthma is a world wide public health problem. It is the most commom chronic disease of school age children. Its severity is in constant increase. The frequency of the hospitalizations for asthma increased in practically all countries. Physical exercises and sport are used more and more as therapeutic means, in northern deveopped countries of where it was very early understood that it is necessary to integrate the asthmatic subjects into a program of specific physical training. This study undertaken in south saharian african country considers also assiduity in a physical training program as the factor of increase in the expiratory peak flow, of reinforcement of some principal muscles necessary to the improvement, and of the respiratory function of the asthmatic subject. Physical exercise is used as a non pharmacological therapy of asthma. This transversal study was carried out on fourteen asthmatic subjects of colleges in Porto-Novo's town, aged 15 years old to 25 years, of the two sexes. The results showed that: the Expiratory Peak Flow of Point (EPF) of the subjects at the beginning of the program is lower than the minimal average value of the group whatever the sex; the subjects average EPF increased from approximately 35% compared to the average at the beginning of the program; the subjects from family with asthmatic line, are much more inclined with respiratory embarrassments post-exercises than those who did not come from it; the respiratory embarrassments post-exercises noticed in the first weeks, grew blurred before the end of the program. This study suggests physical exercise adapted to the asthmatic subjects for the improvement of their health.

  3. Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract

    Science.gov (United States)

    Tsujino, H.; Jones, M.; Shiota, T.; Qin, J. X.; Greenberg, N. L.; Cardon, L. A.; Morehead, A. J.; Zetts, A. D.; Travaglini, A.; Bauer, F.; hide

    2001-01-01

    Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.

  4. Methods for estimating peak-flow frequencies at ungaged sites in Montana based on data through water year 2011: Chapter F in Montana StreamStats

    Science.gov (United States)

    Sando, Roy; Sando, Steven K.; McCarthy, Peter M.; Dutton, DeAnn M.

    2016-04-05

    The U.S. Geological Survey (USGS), in cooperation with the Montana Department of Natural Resources and Conservation, completed a study to update methods for estimating peak-flow frequencies at ungaged sites in Montana based on peak-flow data at streamflow-gaging stations through water year 2011. The methods allow estimation of peak-flow frequencies (that is, peak-flow magnitudes, in cubic feet per second, associated with annual exceedance probabilities of 66.7, 50, 42.9, 20, 10, 4, 2, 1, 0.5, and 0.2 percent) at ungaged sites. The annual exceedance probabilities correspond to 1.5-, 2-, 2.33-, 5-, 10-, 25-, 50-, 100-, 200-, and 500-year recurrence intervals, respectively.Regional regression analysis is a primary focus of Chapter F of this Scientific Investigations Report, and regression equations for estimating peak-flow frequencies at ungaged sites in eight hydrologic regions in Montana are presented. The regression equations are based on analysis of peak-flow frequencies and basin characteristics at 537 streamflow-gaging stations in or near Montana and were developed using generalized least squares regression or weighted least squares regression.All of the data used in calculating basin characteristics that were included as explanatory variables in the regression equations were developed for and are available through the USGS StreamStats application (http://water.usgs.gov/osw/streamstats/) for Montana. StreamStats is a Web-based geographic information system application that was created by the USGS to provide users with access to an assortment of analytical tools that are useful for water-resource planning and management. The primary purpose of the Montana StreamStats application is to provide estimates of basin characteristics and streamflow characteristics for user-selected ungaged sites on Montana streams. The regional regression equations presented in this report chapter can be conveniently solved using the Montana StreamStats application.Selected results from

  5. Effects of Air Stacking Maneuver on Cough Peak Flow and Chest Wall Compartmental Volumes of Subjects With Amyotrophic Lateral Sclerosis.

    Science.gov (United States)

    Sarmento, Antonio; Resqueti, Vanessa; Dourado-Júnior, Mario; Saturnino, Lailane; Aliverti, Andrea; Fregonezi, Guilherme; de Andrade, Armele Dornelas

    2017-11-01

    To assess the acute effects of air stacking on cough peak flow (CPF) and chest wall compartmental volumes of persons with amyotrophic lateral sclerosis (ALS) versus healthy subjects positioned at 45° body inclination. Cross-sectional study with a matched-pair design. University hospital. Persons (N=24) with ALS (n=12) and age-matched healthy subjects (n=12). CPF, chest wall compartmental inspiratory capacity, chest wall vital capacity, chest wall tidal volume and operational volumes, breathing pattern, and percentage of contribution of the compartments to the inspired volume were measured by optoelectronic plethysmography. Compared with healthy subjects, significantly lower CPF (P=.007), chest wall compartmental inspiratory capacity (Pprotocol in the healthy subjects, mainly because of end-inspiratory (P<.001) and abdominal volumes (P=.008). No significant differences were observed in percentage of contribution of the compartments to the inspired volume and end-expiratory volume of both groups. No significant differences were found in chest wall tidal volume, operational volume, and breathing pattern in persons with ALS. Air stacking is effective in increasing CPF, chest wall compartmental inspiratory capacity, and chest wall vital capacity of persons with ALS with no hyperinflation. Differences in compartmental volume contributions are probably because of lung and chest wall physiological changes. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  6. Methods for peak-flow frequency analysis and reporting for streamgages in or near Montana based on data through water year 2015

    Science.gov (United States)

    Sando, Steven K.; McCarthy, Peter M.

    2018-05-10

    This report documents the methods for peak-flow frequency (hereinafter “frequency”) analysis and reporting for streamgages in and near Montana following implementation of the Bulletin 17C guidelines. The methods are used to provide estimates of peak-flow quantiles for 50-, 42.9-, 20-, 10-, 4-, 2-, 1-, 0.5-, and 0.2-percent annual exceedance probabilities for selected streamgages operated by the U.S. Geological Survey Wyoming-Montana Water Science Center (WY–MT WSC). These annual exceedance probabilities correspond to 2-, 2.33-, 5-, 10-, 25-, 50-, 100-, 200-, and 500-year recurrence intervals, respectively.Standard procedures specific to the WY–MT WSC for implementing the Bulletin 17C guidelines include (1) the use of the Expected Moments Algorithm analysis for fitting the log-Pearson Type III distribution, incorporating historical information where applicable; (2) the use of weighted skew coefficients (based on weighting at-site station skew coefficients with generalized skew coefficients from the Bulletin 17B national skew map); and (3) the use of the Multiple Grubbs-Beck Test for identifying potentially influential low flows. For some streamgages, the peak-flow records are not well represented by the standard procedures and require user-specified adjustments informed by hydrologic judgement. The specific characteristics of peak-flow records addressed by the informed-user adjustments include (1) regulated peak-flow records, (2) atypical upper-tail peak-flow records, and (3) atypical lower-tail peak-flow records. In all cases, the informed-user adjustments use the Expected Moments Algorithm fit of the log-Pearson Type III distribution using the at-site station skew coefficient, a manual potentially influential low flow threshold, or both.Appropriate methods can be applied to at-site frequency estimates to provide improved representation of long-term hydroclimatic conditions. The methods for improving at-site frequency estimates by weighting with regional

  7. Effect of bedding control on amount of house dust mite allergens, asthma symptoms, and peak expiratory flow rate.

    Science.gov (United States)

    Lee, Inn-Sook

    2003-04-30

    This quasi-experimental study was designed to investigate the effect of bedding control on the amount of house dust mite (HDM) allergens, asthma symptoms, and peak expiratory flow rate (PEFR) in asthmatics sensitive to HDMs. The subjects in the study were drawn from patients receiving treatment at the allergy clinics of three university-affiliated hospitals in Seoul. Forty-two patients without prior practice of the bedding control used in this study were selected. They commonly showed bronchial asthma caused by HDMs, and exhibited strong positive points (more than 3 points) in skin prick test (D. farinae, D. pteronyssinus), and positive response in both fluoro-allergosorbent test (FAST), and PC20 methacholine test. Of the subjects, alternatively, 22 were assigned to the experimental group and 20 to control group. Bedding control consisted of the use of outer cotton covers, boiling them for 10 minutes fortnightly, and disinfecting bedding by sunlight fortnightly. The experimental group was under bedding control for 4 weeks. The data were collected from October 2000 to January 2001. The results were as follows: 1. After bedding control, the total amount of HDM allergens decreased significantly in the experimental group. However there was no significant difference in the decrease of the amount of HDM allergens between the two groups. 2. Of the asthma symptoms, there was significant difference only in the decrease of the frequency of dyspnea, and in the increase of sleeping disturbance between the two groups after bedding control. 3. After bedding control, PEFR increased in the experimental group whereas it decreased in the control group. However, neither change was significant. The above findings indicate that bedding control improved several asthma symptoms in asthmatics sensitive to HDMs. Accordingly, we suggest that bedding control is adopted as a useful nursing intervention in the field.

  8. Does Peak Urine Flow Rate Predict the Development of Incident Lower Urinary Tract Symptoms in Men with Mild to No Current Symptoms? Results from REDUCE.

    Science.gov (United States)

    Simon, Ross M; Howard, Lauren E; Moreira, Daniel M; Roehrborn, Claus; Vidal, Adriana; Castro-Santamaria, Ramiro; Freedland, Stephen J

    2017-09-01

    We determined whether decreased peak urine flow is associated with future incident lower urinary tract symptoms in men with mild to no lower urinary tract symptoms. Our population consisted of 3,140 men from the REDUCE (Reduction by Dutasteride of Prostate Cancer Events) trial with mild to no lower urinary tract symptoms, defined as I-PSS (International Prostate Symptom Score) less than 8. REDUCE was a randomized trial of dutasteride vs placebo for prostate cancer prevention in men with elevated prostate specific antigen and negative biopsy. I-PSS measures were obtained every 6 months throughout the 4-year study. The association between peak urine flow rate and progression to incident lower urinary tract symptoms, defined as the first of medical treatment, surgery or sustained and clinically significant lower urinary tract symptoms, was tested by multivariable Cox models, adjusting for various baseline characteristics and treatment arm. On multivariable analysis as a continuous variable, decreased peak urine flow rate was significantly associated with an increased risk of incident lower urinary tract symptoms (p = 0.002). Results were similar in the dutasteride and placebo arms. On univariable analysis when peak flow was categorized as 15 or greater, 10 to 14.9 and less than 10 ml per second, flow rates of 10 to 14.9 and less than 10 ml per second were associated with a significantly increased risk of incident lower urinary tract symptoms (HR 1.39, p = 0.011 and 1.67, p urinary tract symptoms a decreased peak urine flow rate is independently associated with incident lower urinary tract symptoms. If confirmed, these men should be followed closer for incident lower urinary tract symptoms. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. Peak negative myocardial velocity gradient in early diastole as a noninvasive indicator of left ventricular diastolic function: comparison with transmitral flow velocity indices.

    Science.gov (United States)

    Shimizu, Y; Uematsu, M; Shimizu, H; Nakamura, K; Yamagishi, M; Miyatake, K

    1998-11-01

    We sought to assess the clinical significance of peak negative myocardial velocity gradient (MVG) in early diastole as a noninvasive indicator of left ventricular (LV) diastolic function. Peak systolic MVG has been shown useful for the quantitative assessment of regional wall motion abnormalities, but limited data exist regarding the diastolic MVG as an indicator of LV diastolic function. Peak negative MVG was obtained from M-mode tissue Doppler imaging (TDI) in 43 subjects with or without impairment of systolic and diastolic performance: 12 normal subjects, 12 patients with hypertensive heart disease (HHD) with normal systolic performance and 19 patients with dilated cardiomyopathy (DCM), and was compared with standard Doppler transmitral flow velocity indices. In a subgroup of 30 patients, effects of preload increase on these indices were assessed by performing passive leg lifting. In an additional 11 patients with congestive heart failure at the initial examination, the measurements were repeated after 26+/-16 days of volume-reducing therapy. Peak negative MVG was significantly depressed both in HHD (-3.9+/-1.3/s, p indices failed to distinguish DCM from normal due to the pseudonormalization. Transmitral flow velocity indices were significantly altered (peak early/late diastolic filling velocity [E/A]=1.1+/-0.5 to 1.5+/-0.7, p indicator of LV diastolic function that is less affected by preload alterations than the transmitral flow velocity indices, and thereby could be used for the follow-up of patients with nonischemic LV dysfunction presenting congestive heart failure.

  10. Peak Flow Responses to Forest Harvesting and Roads in the Maritime Regions of the Pacific Northwest: A Preferential Hillslope Runoff Perspective

    Science.gov (United States)

    Alila, Y.; Schnorbus, M.

    2005-12-01

    The debate regarding peak flow responses to forest clearcutting and road building in the maritime regions of the Pacific Northwest has attracted much attention over the past several decades and its outcome is an important scientific and operational concern. Although there appears to be general consensus that small peak discharge events are increased following forest management activities, little conclusive evidence exists regarding the impact of forest management activities on large events. Statistical tests in traditional paired watershed studies have been used to accept or reject hypotheses regarding peak flow responses to clearcutting and roads but provided no insight into watershed processes and other factors leading to their outcome. Furthermore, statistical analyses of peak flow responses to forestry activities in traditional paired watershed studies are confounded by the many factors that may contribute to management effects on watershed hydrology as well as by issues such as shortness of streamflow records and climate variability. To this end, a new perspective is offered in the debate regarding peak flow responses to clearcutting and road building in the maritime regions of the Pacific Northwest by combining numerical modeling with high-quality hydro-meteorological data collected at the 10-km2 Carnation Creek on the west coast of Vancouver Island, British Columbia (BC). In this approach we explicitly account for changes in evapotranspiration loss, forest road construction and, in particular, introduce the concept of the competing influences of matrix versus preferential hillslope runoff. For scenarios involving road construction, forest clearcutting (52% cut rate) and roads and clearcutting combined, peak discharge increases decrease with decreasing event frequency and statistically significant ( = 0.05) increases in peak flow are confined to events with a 1 year or lower return period. For a range of return periods from 0.17 to 20 years, the effect (i

  11. Distribution of peak expiratory flow variability by age, gender and smoking habits in a random population sample aged 20-70 yrs

    NARCIS (Netherlands)

    Boezen, H M; Schouten, J. P.; Postma, D S; Rijcken, B

    1994-01-01

    Peak expiratory flow (PEF) variability can be considered as an index of bronchial lability. Population studies on PEF variability are few. The purpose of the current paper is to describe the distribution of PEF variability in a random population sample of adults with a wide age range (20-70 yrs),

  12. Ratio of left ventricular peak E-wave velocity to flow propagation velocity assessed by color M-mode Doppler echocardiography in first myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Seward, J B

    2000-01-01

    OBJECTIVES: To determine the ability of the ratio of peak E-wave velocity to flow propagation velocity (E/Vp) measured with color M-mode Doppler echocardiography to predict in-hospital heart failure and cardiac mortality in an unselected consecutive population with first myocardial infarction (MI...

  13. Simulation of water-surface elevations for a hypothetical 100-year peak flow in Birch Creek at the Idaho National Engineering and Environmental Laboratory, Idaho

    International Nuclear Information System (INIS)

    Berenbrock, C.; Kjelstrom, L.C.

    1997-01-01

    Delineation of areas at the Idaho National Engineering and Environmental Laboratory that would be inundated by a 100-year peak flow in Birch Creek is needed by the US Department of Energy to fulfill flood-plain regulatory requirements. Birch Creek flows southward about 40 miles through an alluvium-filled valley onto the northern part of the Idaho National Engineering and Environmental laboratory site on the eastern Snake River Plain. The lower 10-mile reach of Birch Creek that ends in Birch Creek Playa near several Idaho National Engineering and Environmental Laboratory facilities is of particular concern. Twenty-six channel cross sections were surveyed to develop and apply a hydraulic model to simulate water-surface elevations for a hypothetical 100-year peak flow in Birch Creek. Model simulation of the 100-year peak flow (700 cubic feet per second) in reaches upstream from State Highway 22 indicated that flow was confined within channels even when all flow was routed to one channel. Where the highway crosses Birch Creek, about 315 cubic feet per second of water was estimated to move downstream--115 cubic feet per second through a culvert and 200 cubic feet per second over the highway. Simulated water-surface elevation at this crossing was 0.8 foot higher than the elevation of the highway. The remaining 385 cubic feet per second flowed southwestward in a trench along the north side of the highway. Flow also was simulated with the culvert removed. The exact location of flood boundaries on Birch Creek could not be determined because of the highly braided channel and the many anthropogenic features (such as the trench, highway, and diversion channels) in the study area that affect flood hydraulics and flow. Because flood boundaries could not be located exactly, only a generalized flood-prone map was developed

  14. Comparative evaluation of ventilatory function through pre and postoperative peak expiratory flow in patients submitted to elective upper abdominal surgery.

    Science.gov (United States)

    Scheeren, Caio Fernando Cavanus; Gonçalves, José Júlio Saraiva

    2016-01-01

    to evaluate the ventilatory function by Peak Expiratory Flow (PEF) in the immediate pre and postoperative periods of patients undergoing elective surgical procedures in the upper abdomen. we conducted a prospective cohort study including 47 patients admitted to the Hospital Regional de Mato Grosso do Sul from July to December 2014, who underwent elective surgeries of the upper abdomen, and submiited to spirometric evaluation and measurement of PEF immediately before and after surgery. of the 47 patients, 22 (46.8%) were male and 25 (53.20%) female. The mean preoperative PEF was 412.1±91.7, and postoperative, 331.0±87.8, indicating significant differences between the two variables. Men had higher PEF values than women, both in the pre and postoperative periods. There was a reasonable inverse correlation between age and decreased PEF. Both situations showed statistical significance (pvalores de PFE do que o feminino, tanto no pré-cirúrgico quanto no pós-cirúrgico. Observou-se razoável correlação inversamente proporcional entre as variáveis idade e diminuição do PFE. Ambas as situações mostraram significância estatística (pvalores de PFE tanto no pré como no pós-operatório. O grupo composto por portadores de co-morbidades (HAS e/ou DM) apresentou menores valores de PFE tanto no pré como no pós-operatório (p=0,005). Em ambos os grupos, o pós-operatório determinou uma diminuição significativa do PFE (p<0,001). O tipo de cirurgia realizada e o tipo de anestesia não mostraram diferenças significantes em relação ao PFE. as variáveis mais implicadas na diminuição da função ventilatória, avaliadas através da PFE, foram: idade avançada, tabagismo e presença de comorbidades.

  15. Analysis of the Unsteady Flow Field in a Centrifugal Compressor from Peak Efficiency to Near Stall with Full-Annulus Simulations

    Directory of Open Access Journals (Sweden)

    Yannick Bousquet

    2014-01-01

    Full Text Available This study concerns a 2.5 pressure ratio centrifugal compressor stage consisting of a splittered unshrouded impeller and a vaned diffuser. The aim of this paper is to investigate the modifications of the flow structure when the operating point moves from peak efficiency to near stall. The investigations are based on the results of unsteady three-dimensional simulations, in a calculation domain comprising all the blade. A detailed analysis is given in the impeller inducer and in the vaned diffuser entry region through time-averaged and unsteady flow field. In the impeller inducer, this study demonstrates that the mass flow reduction from peak efficiency to near stall leads to intensification of the secondary flow effects. The low momentum fluid accumulated near the shroud interacts with the main flow through a shear layer zone. At near stall condition, the interface between the two flow structures becomes unstable leading to vortices development. In the diffuser entry region, by reducing the mass flow, the high incidence angle from the impeller exit induces a separation on the diffuser vane suction side. At near stall operating point, vorticity from the separation is shed into vortex cores which are periodically formed and convected downstream along the suction side.

  16. Methods for estimating magnitude and frequency of floods in Arizona, developed with unregulated and rural peak-flow data through water year 2010

    Science.gov (United States)

    Paretti, Nicholas V.; Kennedy, Jeffrey R.; Turney, Lovina A.; Veilleux, Andrea G.

    2014-01-01

    Flooding is among the worst natural disasters responsible for loss of life and property in Arizona, underscoring the importance of accurate estimation of flood magnitude for proper structural design and floodplain mapping. Twenty-four years of additional peak-flow data have been recorded since the last comprehensive regional flood frequency analysis conducted in Arizona. Periodically, flood frequency estimates and regional regression equations must be revised to maintain the accurate estimation of flood frequency and magnitude.

  17. Two-dimensional hydrodynamic modeling to quantify effects of peak-flow management on channel morphology and salmon-spawning habitat in the Cedar River, Washington

    Science.gov (United States)

    Czuba, Christiana; Czuba, Jonathan A.; Gendaszek, Andrew S.; Magirl, Christopher S.

    2010-01-01

    The Cedar River in Washington State originates on the western slope of the Cascade Range and provides the City of Seattle with most of its drinking water, while also supporting a productive salmon habitat. Water-resource managers require detailed information on how best to manage high-flow releases from Chester Morse Lake, a large reservoir on the Cedar River, during periods of heavy precipitation to minimize flooding, while mitigating negative effects on fish populations. Instream flow-management practices include provisions for adaptive management to promote and maintain healthy aquatic habitat in the river system. The current study is designed to understand the linkages between peak flow characteristics, geomorphic processes, riverine habitat, and biological responses. Specifically, two-dimensional hydrodynamic modeling is used to simulate and quantify the effects of the peak-flow magnitude, duration, and frequency on the channel morphology and salmon-spawning habitat. Two study reaches, representative of the typical geomorphic and ecologic characteristics of the Cedar River, were selected for the modeling. Detailed bathymetric data, collected with a real-time kinematic global positioning system and an acoustic Doppler current profiler, were combined with a LiDAR-derived digital elevation model in the overbank area to develop a computational mesh. The model is used to simulate water velocity, benthic shear stress, flood inundation, and morphologic changes in the gravel-bedded river under the current and alternative flood-release strategies. Simulations of morphologic change and salmon-redd scour by floods of differing magnitude and duration enable water-resource managers to incorporate model simulation results into adaptive management of peak flows in the Cedar River. PDF version of a presentation on hydrodynamic modelling in the Cedar River in Washington state. Presented at the American Geophysical Union Fall Meeting 2010.

  18. Peak flow meter with a questionnaire and mini-spirometer to help detect asthma and COPD in real-life clinical practice: a cross-sectional study.

    Science.gov (United States)

    Thorat, Yogesh T; Salvi, Sundeep S; Kodgule, Rahul R

    2017-05-09

    Peak flow meter with questionnaire and mini-spirometer are considered as alternative tools to spirometry for screening of asthma and chronic obstructive pulmonary disease. However, the accuracy of these tools together, in clinical settings for disease diagnosis, has not been studied. Two hundred consecutive patients with respiratory complaints answered a short symptom questionnaire and performed peak expiratory flow measurements, standard spirometry with Koko spirometer and mini-spirometry (COPD-6). Spirometry was repeated after bronchodilation. Physician made a final diagnosis of asthma, chronic obstructive pulmonary disease and others. One eighty nine patients (78 females) with age 51 ± 17 years with asthma (115), chronic obstructive pulmonary disease (33) and others (41) completed the study. "Breathlessness > 6months" and "cough > 6months" were important symptoms to detect obstructive airways disease. "Asymptomatic period > 2 weeks" had the best sensitivity (Sn) and specificity (Sp) to differentiate asthma and chronic obstructive pulmonary disease. A peak expiratory flow of meter with few symptom questions can be effectively used in clinical practice for objective detection of asthma and chronic obstructive pulmonary disease, in the absence of good quality spirometry. Mini-spirometers are useful in detection of obstructive airways diseases but FEV 1 measured is inaccurate. DIFFERENTIATING CONDITIONS IN POORLY-EQUIPPED SETTINGS: A simple questionnaire and peak flow meter measurements can help doctors differentiate between asthma and chronic lung disease. In clinical settings where access to specialist equipment and knowledge is limited, it can be challenging for doctors to tell the difference between asthma and chronic obstructive pulmonary disease (COPD). To determine a viable alternative method for differentiating between these diseases, Rahul Kodgule and colleagues at the Chest Research Foundation in Pune, India, trialed a simplified version

  19. An asthma patient with steroid-resistant decrease in peak expiratory flow after the Great East Japan earthquake showing spontaneous recovery after 1 month.

    Science.gov (United States)

    Yanagimoto, Shintaro; Haida, Michiko; Suko, Matsunobu

    2012-01-01

    People living in Japan were affected in various ways after the Great East Japan earthquake of March 11, 2011. A 52-year-old female asthma patient not directly affected by the disaster experienced a decrease in peak expiratory flow (PEF) immediately after the earthquake. Despite increasing the inhaled and oral corticosteroid doses, her PEF did not recover. One month later, her PEF level abruptly returned to normal with minimal medications, which were previously ineffective, and the asthma-related symptoms vanished. The stabilization of her state of mind and actual social state seemed to be a part of the reason for the patient's recovery.

  20. Changes in planform geomorphology and vegetation of the Umatilla River during a 50-year period of diminishing peak flow

    Science.gov (United States)

    Hughes, M. L.; McDowell, P. F.

    2017-12-01

    The Umatilla River of northeastern Oregon is a gravel-bedded, mixed pattern, salmonid-bearing channel-floodplain system typical of the Interior Columbia River Basin. Efforts to restore native salmonids in this region since the 1980's coupled with increased scrutiny of flood- and erosion-control activities have prompted a need for better understanding of the biogemorphic implications of flood disturbances. The goals of this study are: (1) to re-examine results of earlier studies of flood impacts on the Umatilla River in light of more recent flow records, and (2) to investigate the degree to which large floods have influenced existing patterns of channel-floodplain geomorphology and vegetation. Mapping of flowing channels, bars, scoured surfaces, and vegetation within the active channel from of aerial photos bracketing flood and inter-flood periods since 1964 indicates complex and spatially variable channel changes. In general, channel scour was the most consistent response to flooding. The direction (gain/loss) and magnitude of changes in bars and vegetation within the active channel, as well as the amount of lateral channel movement and changes in sinuosity, were generally inconsistent across flood events. The removal of vegetation by scour during floods was in many areas compensated by the capture of vegetation from the floodplain by avulsion and activation of secondary channels. To date, the geomorphic impacts of the 1964-65 flood-of-record have not been replicated, despite an overall increase in the frequency of smaller floods. Expansion of riparian vegetation in recent decades has mainly occurred in areas disturbed by scour and bar deposition during the 1964-65 floods. Vegetative succession during this period has caused contraction of the active channel such that it now appears much as it did before the 1964-65 floods. These results underscore the importance of large floods as drivers of biogeormphic processes and patterns over timescales relevant to river

  1. Description of the Retention and Peak Profile for Chromolith Columns in Isocratic and Gradient Elution Using Mobile Phase Composition and Flow Rate as Factors

    Directory of Open Access Journals (Sweden)

    Elsa Cabo-Calvet

    2014-11-01

    Full Text Available The effect of the modifier concentration and flow rate on the chromatographic performance of a second generation Chromolith® RP-18e column, under isocratic and gradient elution with acetonitrile-water mixtures, was examined using four sulphonamides as probe compounds. The acetonitrile concentration was varied between 5 and 55% (v/v, and the flow rate between 0.1 and 5.0 mL/min, keeping the other factors constant. The changes in both retention and peak profile were modelled, and used to build simple plots, where the logarithm of the retention factor was represented against the modifier concentration (in gradient elution, against the initial modifier concentration, and the half-widths or widths against the retention time (in gradient elution, against the time at the column outlet. A particular plot was needed for describing the retention of each sulphonamide, but due to the similar interaction kinetics, a unique plot described the changes in the half-widths for all four sulphonamides. The changes in retention with the flow showed that allegedly in the second generation Chromolith, the column deformation observed for the first generation Chromolith, with the applied pressure at increasing flow, is decreased.

  2. Hydrological model calibration for flood prediction in current and future climates using probability distributions of observed peak flows and model based rainfall

    Science.gov (United States)

    Haberlandt, Uwe; Wallner, Markus; Radtke, Imke

    2013-04-01

    Derived flood frequency analysis based on continuous hydrological modelling is very demanding regarding the required length and temporal resolution of precipitation input data. Often such flood predictions are obtained using long precipitation time series from stochastic approaches or from regional climate models as input. However, the calibration of the hydrological model is usually done using short time series of observed data. This inconsistent employment of different data types for calibration and application of a hydrological model increases its uncertainty. Here, it is proposed to calibrate a hydrological model directly on probability distributions of observed peak flows using model based rainfall in line with its later application. Two examples are given to illustrate the idea. The first one deals with classical derived flood frequency analysis using input data from an hourly stochastic rainfall model. The second one concerns a climate impact analysis using hourly precipitation from a regional climate model. The results show that: (I) the same type of precipitation input data should be used for calibration and application of the hydrological model, (II) a model calibrated on extreme conditions works quite well for average conditions but not vice versa, (III) the calibration of the hydrological model using regional climate model data works as an implicit bias correction method and (IV) the best performance for flood estimation is usually obtained when model based precipitation and observed probability distribution of peak flows are used for model calibration.

  3. 'Peak oil' or 'peak demand'?

    International Nuclear Information System (INIS)

    Chevallier, Bruno; Moncomble, Jean-Eudes; Sigonney, Pierre; Vially, Rolland; Bosseboeuf, Didier; Chateau, Bertrand

    2012-01-01

    This article reports a workshop which addressed several energy issues like the objectives and constraints of energy mix scenarios, the differences between the approaches in different countries, the cost of new technologies implemented for this purposes, how these technologies will be developed and marketed, which will be the environmental and societal acceptability of these technical choices. Different aspects and issues have been more precisely presented and discussed: the peak oil, development of shale gases and their cost (will non conventional hydrocarbons modify the peak oil and be socially accepted?), energy efficiency (its benefits, its reality in France and other countries, its position in front of the challenge of energy transition), and strategies in the transport sector (challenges for mobility, evolution towards a model of sustainable mobility)

  4. Peak-flow frequency analyses and results based on data through water year 2011 for selected streamflow-gaging stations in or near Montana: Chapter C in Montana StreamStats

    Science.gov (United States)

    Sando, Steven K.; McCarthy, Peter M.; Dutton, DeAnn M.

    2016-04-05

    Chapter C of this Scientific Investigations Report documents results from a study by the U.S. Geological Survey, in cooperation with the Montana Department of Transportation and the Montana Department of Natural Resources, to provide an update of statewide peak-flow frequency analyses and results for Montana. The purpose of this report chapter is to present peak-flow frequency analyses and results for 725 streamflow-gaging stations in or near Montana based on data through water year 2011. The 725 streamflow-gaging stations included in this study represent nearly all streamflowgaging stations in Montana (plus some from adjacent states or Canadian Provinces) that have at least 10 years of peak-flow records through water year 2011. For 29 of the 725 streamflow-gaging stations, peak-flow frequency analyses and results are reported for both unregulated and regulated conditions. Thus, peak-flow frequency analyses and results are reported for a total of 754 analyses. Estimates of peak-flow magnitudes for 66.7-, 50-, 42.9-, 20-, 10-, 4-, 2-, 1-, 0.5-, and 0.2-percent annual exceedance probabilities are reported. These annual exceedance probabilities correspond to 1.5-, 2-, 2.33-, 5-, 10-, 25-, 50-, 100-, 200-, and 500-year recurrence intervals.

  5. Measuring Your Peak Flow Rate

    Science.gov (United States)

    ... based on a person's age, height, sex and race. A standardized "normal" may be obtained from a ... Climb LUNG FORCE Walks Cycling Events Donate a Car Memorial & Honor Gifts Planned Giving Christmas Seals ABOUT ...

  6. Peak flow meter use - slideshow

    Science.gov (United States)

    ... Duplication for commercial use must be authorized in writing by ADAM Health Solutions. About MedlinePlus Site Map FAQs Customer Support Get email updates Subscribe to RSS Follow us Disclaimers Copyright ...

  7. Factors Affecting the Improvement of the Initial Peak Urinary Flow Rate after Transurethral Resection of the Prostate or Photoselective Vaporization of the Prostate for Treating Benign Prostatic Hyperplasia

    Directory of Open Access Journals (Sweden)

    Hwa Sub Choi

    2011-03-01

    Full Text Available Purpose We evaluated the factors that affect the improvement of the initial peak flow rate after transurethral resection of the prostate (TURP or photoselective vaporization of the prostate (PVP for benign prostatic hyperplasia (BPH patients by using noninvasive tools. Methods One hundred and twenty seven BPH patients who had undergone TURP or PVP between January 2005 and May 2009 were evaluated. They were divided into 2 groups: the postoperative initial peak urinary flow rate (Qmax was less than 10 mL/sec (Group 1; n=37, TURP=11, PVP=26 and more than 10 mL/sec (Group 2; n=90, TURP=41, PVP=49. We confirmed the patients' preoperative check lists. The check list were the international prostate symptom score (IPSS, the quality of life score, a past history of acute urinary retention (AUR, body mass index and/or pyuria, the serum prostate-specific antigen (PSA level and the prostate volume, the prostate transitional zone volume and prostatic calcification. The initial Qmax was measured at the outpatient clinic one week after discharge. Results The improvement rate was not significant difference between the TURP group (78.8% and the PVP group (65.3%. The efficacy parameters were the IPSS-storage symptom score, the prostate volume, the PSA level and a past history of AUR. The IPSS-storage symptom scores of Group 1 (12.3±3.3 was higher than those of Group 2 (10.5±1.7. The prostate volume of Group 2 (42.3±16.6 g was bigger than that of Group 1 (36.6±7.8 g. The PSA level of Group 2 (3.8±2.6 ng/mL was higher than that of Group 1 (2.6±2.6 ng/mL. A past history of AUR in Group 1 (35.1% was more prevalent than that of Group 2 (15.6%. Conclusions The non-invasive factors affecting the initial Qmax after TURP or PVP were the IPSS-storage symptom score, the prostate volume and a past history of AUR. Accordingly, in patients who have a higher IPSS-storage symptom score, a smaller prostate volume and a history of AUR, there might be a detrimental effect on

  8. Feasibility study of respiratory questionnaire and peak flow recordings in autobody shop workers exposed to isocyanate-containing spray paint: observations and limitations.

    Science.gov (United States)

    Cullen, M R; Redlich, C A; Beckett, W S; Weltmann, B; Sparer, J; Jackson, G; Ruff, T; Rubinstein, E; Holden, W

    1996-06-01

    Diisocyanates, highly reactive monomers which cross-link polyurethane, are the most widely recognized causes of occupational asthma. Many exposed workers are end-users, including autobody spray painters who form a large population at risk. Neither the factors which determine incidence rate nor strategies for control have been adequately studied in this setting. We have conducted a cross-sectional survey of 23 (about one in five) autobody shops in the New Haven area to determine the feasibility of clinical epidemiological studies in this population. Among 102 workers, there was a high rate of airway symptoms consistent with occupational asthma (19.6%). Symptoms were most prevalent among those with the greatest opportunity for exposure (dedicated spray painters) and least among office workers; part-time painters had intermediate rates. Atopy was not associated with risk while smoking seemed to correlate with symptoms. Regular use of air-supplied respirators appeared to be associated with lower risk among workers who painted part- or full-time. We were unable to validate the questionnaire responses with peak expiratory flow record data attempted on a 1/3 sample of the workers. Despite intensive training and effort, subject compliance was limited. Among those who provided adequate data (24 of 38), only two demonstrated unequivocal evidence of labile airways; two others demonstrated lesser changes consistent with an occupational effect on flow rates. There was no clear association between these findings and either questionnaire responses or exposure classification. Overall, the survey suggests that there is a high prevalence of airway symptoms among workers in autobody shops, at least in part due to work-related asthma. However, there is need for both methodological and substantive research in this setting to document rates of occupational asthma and to develop a scientific basis for its effective control.

  9. The variability of expiration peak flow of workers employed in the washing installation (laundry) of Haji Adam Malik general hospital Medan

    Science.gov (United States)

    Saragih, W.; Tarigan, A. P.; Nainggolan, N.; Eyanoer, P. C.

    2018-03-01

    Laundress in hospitals is very susceptible to respiratory disorders, especially occupational asthma. To investigate the occurrence of an obstruction, the daily Expiration Peak Flow (EPF) examination was carried to compare the EPF, before and after work. It is a descriptive study conducted in November 2016. The samplewas 24 workers in Haji Adam Malik General Hospital Medan Laundry Installation, without any exclusion criteria, where all workers have been working for more than one year. Sampling was by distributing daily questionnaires and EPF examination for 14 days. From the results of EPF examinations that have been conducted, there were nine persons were indicated to experience a decreased in lung function. Based on the most sex category, men were 5 people (55.6%), age ≥ 40 years were 2 people (22.2%), working duration ≥10 years were 3 people (33.3%), with the smoking habit were 5 people (55.6%), total dust ≥0.2 micron were 6 people (66.7), total exposure of bacterium ≥500 were 3 people (33.3%), poor APD usage was 3 people (33.3%). In conclusion, there was a decrease in lung function by ≥ 3.1% found in 9 workers.

  10. Peak expiratory flow mediates the relationship between handgrip strength and timed up and go performance in elderly women, but not men.

    Science.gov (United States)

    Ritti-Dias, Raphael Mendes; Cucato, Gabriel Grizzo; de Mello Franco, Fábio Gazelato; Cendoroglo, Maysa Seabra; Nasri, Fábio; Monteiro-Costa, Maria Luiza; de Carvalho, José Antonio Maluf; de Matos, Luciana Diniz Nagem Janot

    2016-09-01

    The aim of the present study was to verify if there is sex difference in the associations among handgrip strength, peak expiratory flow (PEF) and timed up and go (TUG) test results. The sample included 288 consecutive elderly men (n=93) and women (n=195). Functional capacity was measured using the TUG test, and muscle strength was measured based on handgrip. Moreover, as a measure of current health status, PEF was evaluated. Linear regression procedures were performed to analyze the relationships between handgrip and both PEF and TUG test results, with adjustment for confounders, and to identify the possible mediating role of PEF in the association between handgrip strength and TUG test results. In men, handgrip strength was associated with both PEF and TUG performance (prelationship between handgrip strength and TUG performance remained significant. In women, handgrip strength was also associated with both PEF and TUG performance (prelationship between handgrip strength and TUG performance was no longer significant. Mobility in the elderly is sex dependent. In particular, PEF mediates the relationship between handgrip strength and TUG performance in women, but not in men.

  11. [PNIF (Peak nasal inspiratory flow) as a method for assessing nasal airway patency in the ECAP (Epidemiology of Allergic Disorders in Poland) multicenter study].

    Science.gov (United States)

    Krzych-Fałta, Edyta; Lusawa, Adam; Samoliński, Bolesław

    2012-01-01

    The aim of the study was to evaluate the usefulness of PNIF in assessing nasal airway patency based on test results. The sample in the study was a group of 4 674 subjects, including 1291 people aged 6-7 years (woman 643, men 648), 1293 people aged 13-14 years (woman 625, men 668) and 2090 adults (woman 1284, men 806). The research method employed in the study was the measurement of peak nasal inspiratory flow using a peak flow meter with a suitable mask as used in rhinomanometry tests and with a flow rate ranging from 20 to 350 l/min. The study was conducted in 2006-2008 at the following centres: Katowice, Wroclaw, Krakow, Lublin, Warszawa, Bydgoszcz, Gdansk and in the rural areas of the former province of Zamosc. For the purposes of the study, the average values for the subjects were calculated for a number of criteria: - subject age: The average PNIF value was 52,41/min for subjects aged 6-7 years(n=1291), 94.7 l/min for subjects aged 13-14 (n=1293) and 108.0 l/min for the adults (n=2090). Indeed statistical dependences for all aged groups were observed on level p<0,0005. -diagnosis: The average PNIF value for healthy was 52,3 l/min p=0,338 for subjects aged 6-7 years (n=680), 97,3 l/min p=0,279 for subjects aged 13-14 (n=640) and 111,7 l/min p=0,438 for the adults (n=1035) and for allergic rhinitis PNIF value was 50,41/min p=0,028 for subjects aged 6-7 years(n=310), 93,3 l/min p=0,299 for subjects aged 13-14 (n=389) and 107,71 1/min p=0,276 for the adults (n=623) and asthma PNIF value was 51,6/min for subjects aged 6-7 years(n=149) 87,3 l/min p=0,062 for subjects aged 13-14 (n=145) p=0,097 and 105,3 l/min p=0,13 for the adults (n=198) -exposure to tobacco smoke (adults): passive smoking - 105,311 min (n=1202) p=0,017, active smoking-119.1 l/min(n=885) p=0,108. PINF is important investigative tool thanks which we can: to differentiate in dependence the functional state of nose from: put the recognition (the patients with allergic rhinitis, the bronchial asthma

  12. Acute effects of particulate matter and black carbon from seasonal fires on peak expiratory flow of schoolchildren in the Brazilian Amazon.

    Directory of Open Access Journals (Sweden)

    Ludmilla da Silva Viana Jacobson

    Full Text Available BACKGROUND: Panel studies have shown adverse effects of air pollution from biomass burning on children's health. This study estimated the effect of current levels of outdoor air pollution in the Amazonian dry season on peak expiratory flow (PEF. METHODS: A panel study with 234 schoolchildren from 6 to 15 years old living in the municipality of Tangará da Serra, Brazil was conducted. PEF was measured daily in the dry season in 2008. Mixed-effects models and unified modelling repeated for every child were applied. Time trends, temperature, humidity, and subject characteristics were regarded. Inhalable particulate matter (PM10, fine particulate matter (PM2.5, and black carbon (BC effects were evaluated based on 24-hour exposure lagged by 1 to 5 days and the averages of 2 or 3 days. Polynomial distributed lag models (PDLM were also applied. RESULTS: The analyses revealed reductions in PEF for PM10 and PM2.5 increases of 10 µg/m(3 and 1 µg/m(3 for BC. For PM10, the reductions varied from 0.15 (confidence interval (CI95%: -0.29; -0.01 to 0.25 l/min (CI95%: -0.40; -0.10. For PM2.5, they ranged from 0.46 (CI95%: -0.86 to -0.06 to 0.54 l/min (CI95%:-0.95; -0.14. As for BC, the reduction was approximately 1.40 l/min. In relation to PDLM, adverse effects were noticed in models based on the exposure on the current day through the previous 3 days (PDLM 0-3 and on the current day through the previous 5 days (PDLM 0-5, specially for PM10. For all children, for PDLM 0-5 the global effect was important for PM10, with PEF reduction of 0.31 l/min (CI95%: -0.56; -0.05. Also, reductions in lags 3 and 4 were observed. These associations were stronger for children between 6 and 8 years old. CONCLUSION: Reductions in PEF were associated with air pollution, mainly for lagged exposures of 3 to 5 days and for younger children.

  13. Hydraulic analysis of looped waster network on peak flow conditions; Analisis hidraulico de redes malladas de abastecimiento en condiciones de maxima demanda

    Energy Technology Data Exchange (ETDEWEB)

    Martinez Solano, F. J.; Iglesias Rey, P. L.; Fuertes Miquel, V. S.; Lopez Jimenez, P. A.

    2007-07-01

    The models of a water supply network are classified in detailed models and strategic models depending on its characteristics. In the case of detailed model, the objective consists of studying the behaviour of the network when extreme situations occurs. Usually, billing data from customers are used to estimate the demands at the network nodes. This made that demand an average value of the flow. In other words, we are using true dat to obtain fictions situations. This is specially tru when the network is smaller. In this article, a methodology to load allocation in detailed models is presented. This load allocation will be valid for both branched and looped networks. (Author) 10 refs.

  14. Future changes in peak river flows across northern Eurasia as inferred from an ensemble of regional climate projections under the IPCC RCP8.5 scenario

    Science.gov (United States)

    Shkolnik, Igor; Pavlova, Tatiana; Efimov, Sergey; Zhuravlev, Sergey

    2018-01-01

    Climate change simulation based on 30-member ensemble of Voeikov Main Geophysical Observatory RCM (resolution 25 km) for northern Eurasia is used to drive hydrological model CaMa-Flood. Using this modeling framework, we evaluate the uncertainties in the future projection of the peak river discharge and flood hazard by 2050-2059 relative to 1990-1999 under IPCC RCP8.5 scenario. Large ensemble size, along with reasonably high modeling resolution, allows one to efficiently sample natural climate variability and increase our ability to predict future changes in the hydrological extremes. It has been shown that the annual maximum river discharge can almost double by the mid-XXI century in the outlets of major Siberian rivers. In the western regions, there is a weak signal in the river discharge and flood hazard, hardly discernible above climate variability. Annual maximum flood area is projected to increase across Siberia mostly by 2-5% relative to the baseline period. A contribution of natural climate variability at different temporal scales to the uncertainty of ensemble prediction is discussed. The analysis shows that there expected considerable changes in the extreme river discharge probability at locations of the key hydropower facilities. This suggests that the extensive impact studies are required to develop recommendations for maintaining regional energy security.

  15. Calibration and fluctuation of the secular frequency peak amplitude versus initial condition distribution of the ion cloud confined into a three-dimensional quadrupole ion trap using a fourier transform operating mode and a steady ion flow injection mode

    International Nuclear Information System (INIS)

    Janulyte, A.; Andre, J.; Carette, M.; Mercury, M.; Reynard, C; Zerega, Y.

    2009-01-01

    A specific Fourier transform operating mode is applied to a 3-dimensional quadrupolar ion trap for mass analysis (Fourier Transform Quadrupolar Ion Trap (FTQIT) Operating Mode or Mass Spectrometer). With this operating mode, an image signal, which is representative of the collective motion of simultaneously confined ions, is made up from a set of recorded time-of-flight histograms. In an ion trap, the secular frequency of ion motion depends on m/Z ratio of the ion. By Fourier transformation of the image signal, one observes the frequency peak of each confined ionic species. When only one ionic species is confined, the peak amplitude is proportional to the maximal amplitude of the image signal. The maximal amplitude of the image signal is expressed according to the operating parameters, the initial conditions of the ions and the number of ions. Simulation tools lead to fluctuation calculation of the maximal amplitude of the image signal. Two origins are explored: (1) the fluctuation of the numbers of ions according to the steady ion flow injection mode (SIFIM) used with this operating mode and (2) the distribution fluctuation of the initial positions and velocities. Initial confinement conditions, obtained with SIFIM injection mode, lead to optimal detection with small fluctuations of the peak amplitude for Fourier transform operating mode applied to an ion trap. (authors)

  16. The geomorphic structure of the runoff peak

    Directory of Open Access Journals (Sweden)

    R. Rigon

    2011-06-01

    Full Text Available This paper develops a theoretical framework to investigate the core dependence of peak flows on the geomorphic properties of river basins. Based on the theory of transport by travel times, and simple hydrodynamic characterization of floods, this new framework invokes the linearity and invariance of the hydrologic response to provide analytical and semi-analytical expressions for peak flow, time to peak, and area contributing to the peak runoff. These results are obtained for the case of constant-intensity hyetograph using the Intensity-Duration-Frequency (IDF curves to estimate extreme flow values as a function of the rainfall return period. Results show that, with constant-intensity hyetographs, the time-to-peak is greater than rainfall duration and usually shorter than the basin concentration time. Moreover, the critical storm duration is shown to be independent of rainfall return period as well as the area contributing to the flow peak. The same results are found when the effects of hydrodynamic dispersion are accounted for. Further, it is shown that, when the effects of hydrodynamic dispersion are negligible, the basin area contributing to the peak discharge does not depend on the channel velocity, but is a geomorphic propriety of the basin. As an example this framework is applied to three watersheds. In particular, the runoff peak, the critical rainfall durations and the time to peak are calculated for all links within a network to assess how they increase with basin area.

  17. Peak Experience Project

    Science.gov (United States)

    Scott, Daniel G.; Evans, Jessica

    2010-01-01

    This paper emerges from the continued analysis of data collected in a series of international studies concerning Childhood Peak Experiences (CPEs) based on developments in understanding peak experiences in Maslow's hierarchy of needs initiated by Dr Edward Hoffman. Bridging from the series of studies, Canadian researchers explore collected…

  18. Peak-interviewet

    DEFF Research Database (Denmark)

    Raalskov, Jesper; Warming-Rasmussen, Bent

    Peak-interviewet er en særlig effektiv metode til at gøre ubevidste menneskelige ressourcer bevidste. Fokuspersonen (den interviewede) interviewes om en selvvalgt, personlig succesoplevelse. Terapeuten/coachen (intervieweren) spørger ind til processen, som ledte hen til denne succes. Herved afdæk...... fokuspersonen ønsker at tage op (nye mål eller nye processer). Nærværende workingpaper beskriver, hvad der menes med et peak-interview, peakinterviwets teoretiske fundament samt metodikken til at foretage et tillidsfuldt og effektiv peak-interview....

  19. Peak power ratio generator

    Science.gov (United States)

    Moyer, R.D.

    A peak power ratio generator is described for measuring, in combination with a conventional power meter, the peak power level of extremely narrow pulses in the gigahertz radio frequency bands. The present invention in a preferred embodiment utilizes a tunnel diode and a back diode combination in a detector circuit as the only high speed elements. The high speed tunnel diode provides a bistable signal and serves as a memory device of the input pulses for the remaining, slower components. A hybrid digital and analog loop maintains the peak power level of a reference channel at a known amount. Thus, by measuring the average power levels of the reference signal and the source signal, the peak power level of the source signal can be determined.

  20. Peak Oil, Peak Coal and Climate Change

    Science.gov (United States)

    Murray, J. W.

    2009-05-01

    Research on future climate change is driven by the family of scenarios developed for the IPCC assessment reports. These scenarios create projections of future energy demand using different story lines consisting of government policies, population projections, and economic models. None of these scenarios consider resources to be limiting. In many of these scenarios oil production is still increasing to 2100. Resource limitation (in a geological sense) is a real possibility that needs more serious consideration. The concept of 'Peak Oil' has been discussed since M. King Hubbert proposed in 1956 that US oil production would peak in 1970. His prediction was accurate. This concept is about production rate not reserves. For many oil producing countries (and all OPEC countries) reserves are closely guarded state secrets and appear to be overstated. Claims that the reserves are 'proven' cannot be independently verified. Hubbert's Linearization Model can be used to predict when half the ultimate oil will be produced and what the ultimate total cumulative production (Qt) will be. US oil production can be used as an example. This conceptual model shows that 90% of the ultimate US oil production (Qt = 225 billion barrels) will have occurred by 2011. This approach can then be used to suggest that total global production will be about 2200 billion barrels and that the half way point will be reached by about 2010. This amount is about 5 to 7 times less than assumed by the IPCC scenarios. The decline of Non-OPEC oil production appears to have started in 2004. Of the OPEC countries, only Saudi Arabia may have spare capacity, but even that is uncertain, because of lack of data transparency. The concept of 'Peak Coal' is more controversial, but even the US National Academy Report in 2007 concluded only a small fraction of previously estimated reserves in the US are actually minable reserves and that US reserves should be reassessed using modern methods. British coal production can be

  1. Peak regulation right

    International Nuclear Information System (INIS)

    Gao, Z. |; Ren, Z.; Li, Z.; Zhu, R.

    2005-01-01

    A peak regulation right concept and corresponding transaction mechanism for an electricity market was presented. The market was based on a power pool and independent system operator (ISO) model. Peak regulation right (PRR) was defined as a downward regulation capacity purchase option which allowed PRR owners to buy certain quantities of peak regulation capacity (PRC) at a specific price during a specified period from suppliers. The PRR owner also had the right to decide whether or not they would buy PRC from suppliers. It was the power pool's responsibility to provide competitive and fair peak regulation trading markets to participants. The introduction of PRR allowed for unit capacity regulation. The PRR and PRC were rated by the supplier, and transactions proceeded through a bidding process. PRR suppliers obtained profits by selling PRR and PRC, and obtained downward regulation fees regardless of whether purchases are made. It was concluded that the peak regulation mechanism reduced the total cost of the generating system and increased the social surplus. 6 refs., 1 tab., 3 figs

  2. Automated asteroseismic peak detections

    DEFF Research Database (Denmark)

    de Montellano, Andres Garcia Saravia Ortiz; Hekker, S.; Themessl, N.

    2018-01-01

    Space observatories such as Kepler have provided data that can potentially revolutionize our understanding of stars. Through detailed asteroseismic analyses we are capable of determining fundamental stellar parameters and reveal the stellar internal structure with unprecedented accuracy. However......, such detailed analyses, known as peak bagging, have so far been obtained for only a small percentage of the observed stars while most of the scientific potential of the available data remains unexplored. One of the major challenges in peak bagging is identifying how many solar-like oscillation modes are visible...... of detected oscillation modes. The algorithm presented here opens the possibility for detailed and automated peak bagging of the thousands of solar-like oscillators observed by Kepler....

  3. Automated asteroseismic peak detections

    Science.gov (United States)

    García Saravia Ortiz de Montellano, Andrés; Hekker, S.; Themeßl, N.

    2018-05-01

    Space observatories such as Kepler have provided data that can potentially revolutionize our understanding of stars. Through detailed asteroseismic analyses we are capable of determining fundamental stellar parameters and reveal the stellar internal structure with unprecedented accuracy. However, such detailed analyses, known as peak bagging, have so far been obtained for only a small percentage of the observed stars while most of the scientific potential of the available data remains unexplored. One of the major challenges in peak bagging is identifying how many solar-like oscillation modes are visible in a power density spectrum. Identification of oscillation modes is usually done by visual inspection that is time-consuming and has a degree of subjectivity. Here, we present a peak-detection algorithm especially suited for the detection of solar-like oscillations. It reliably characterizes the solar-like oscillations in a power density spectrum and estimates their parameters without human intervention. Furthermore, we provide a metric to characterize the false positive and false negative rates to provide further information about the reliability of a detected oscillation mode or the significance of a lack of detected oscillation modes. The algorithm presented here opens the possibility for detailed and automated peak bagging of the thousands of solar-like oscillators observed by Kepler.

  4. Comparison of peak flow velocity through the left ventricular outflow tract and effective orifice area indexed to body surface area in Golden Retriever puppies to predict development of subaortic stenosis in adult dogs.

    Science.gov (United States)

    Javard, Romain; Bélanger, Marie-Claude; Côté, Etienne; Beauchamp, Guy; Pibarot, Philippe

    2014-12-15

    To evaluate the usefulness of Doppler-derived peak flow velocity through the left ventricular outflow tract (LVOT Vmax) and effective orifice area indexed to body surface area (EOAi) in puppies to predict development of subaortic stenosis (SAS) in the same dogs as adults. Prospective, longitudinal, observational study. 38 Golden Retrievers. Cardiac auscultation and echocardiography were performed on 2- to 6-month-old puppies, then repeated at 12 to 18 months. Subaortic stenosis was diagnosed when LVOT Vmax was ≥ 2.3 m/s in adult dogs with left basilar systolic murmurs. All puppies with EOAi 2.3 m/s in puppyhood was 63% sensitive and 100% specific for SAS in adulthood. In puppies, LVOT Vmax was more strongly associated with a future diagnosis of SAS (area under the curve [AUC], 0.89) than was EOAi (AUC, 0.80). In puppies, the combination of LVOT Vmax and EOAi yielded slightly higher sensitivity (69%) and specificity (100%) for adult SAS than did LVOT Vmax alone. In unaffected and affected dogs, LVOT Vmax increased significantly from puppyhood to adulthood but EOAi did not. In Golden Retriever puppies, LVOT Vmax > 2.3 m/s and EOAi < 1.46 cm(2)/m(2) were both associated with a diagnosis of SAS at adulthood. The combination of these 2 criteria may result in higher sensitivity for SAS screening. Unlike LVOT Vmax, EOAi did not change during growth in either unaffected Golden Retrievers or those with SAS.

  5. Peak reading detector circuit

    International Nuclear Information System (INIS)

    Courtin, E.; Grund, K.; Traub, S.; Zeeb, H.

    1975-01-01

    The peak reading detector circuit serves for picking up the instants during which peaks of a given polarity occur in sequences of signals in which the extreme values, their time intervals, and the curve shape of the signals vary. The signal sequences appear in measuring the foetal heart beat frequence from amplitude-modulated ultrasonic, electrocardiagram, and blood pressure signals. In order to prevent undesired emission of output signals from, e. g., disturbing intermediate extreme values, the circuit consists of the series connections of a circuit to simulate an ideal diode, a strong unit, a discriminator for the direction of charging current, a time-delay circuit, and an electronic switch lying in the decharging circuit of the storage unit. The time-delay circuit thereby causes storing of a preliminary maximum value being used only after a certain time delay for the emission of the output signal. If a larger extreme value occurs during the delay time the preliminary maximum value is cleared and the delay time starts running anew. (DG/PB) [de

  6. Estimation of the peak factor based on watershed characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Gauthier, Jean; Nolin, Simon; Ruest, Benoit [BPR Inc., Quebec, (Canada)

    2010-07-01

    Hydraulic modeling and dam structure design require the river flood flow as a primary input. For a given flood event, the ratio of peak flow over mean daily flow defines the peak factor. The peak factor value is dependent on the watershed and location along the river. The main goal of this study consisted in finding a relationship between watershed characteristics and this peak factor. Regression analyses were carried out on 53 natural watersheds located in the southern part of the province of Quebec using data from the Centre d'expertise hydrique du Quebec (CEHQ). The watershed characteristics included in the analyses were the watershed area, the maximum flow length, the mean slope, the lake proportion and the mean elevation. The results showed that watershed area and length are the major parameters influencing the peak factor. Nine natural watersheds were also used to test the use of a multivariable model in order to determine the peak factor for ungauged watersheds.

  7. Computation of peak discharge at culverts

    Science.gov (United States)

    Carter, Rolland William

    1957-01-01

    Methods for computing peak flood flow through culverts on the basis of a field survey of highwater marks and culvert geometry are presented. These methods are derived from investigations of culvert flow as reported in the literature and on extensive laboratory studies of culvert flow. For convenience in computation, culvert flow has been classified into six types, according to the location of the control section and the relative heights of the head-water and tail-water levels. The type of flow which occurred at any site can be determined from the field data and the criteria given in this report. A discharge equation has been developed for each flow type by combining the energy and continuity equations for the distance between an approach section upstream from the culvert and a terminal section within the culvert barrel. The discharge coefficient applicable to each flow type is listed for the more common entrance geometries. Procedures for computing peak discharge through culverts are outlined in detail for each of the six flow types.

  8. Validez en el registro del pico espiratorio máximo de niños asmáticos de la Ciudad de México Validity of peak flow record in asthmatic children residing in Mexico City

    Directory of Open Access Journals (Sweden)

    Diana Jiménez-Millán

    2007-06-01

    Full Text Available OBJETIVO: Determinar la concordancia entre el pico espiratorio forzado (PEF registrado por padres de niños asmáticos y el PEF electrónico que es el almacenado en el AirWatch (PEFe. MATERIAL Y MÉTODOS: Se obtuvo el PEF de 42 niños de 5 a 15 años de edad del Hospital Infantil de México Federico Gómez de la Ciudad de México entre octubre de 1998 y 1999. Los padres registraron el valor máximo del PEF en un diario de salud. Se calculó la correlación de Spearman entre el PEFe y el PEFr. Utilizamos un modelo logístico de efectos mixtos. RESULTADOS: La correlación del PEFe y el PEFr fue r= 0.96 (pOBJECTIVE: To determine the concordance between maximum peak expiratory flow records (PEFr reported by the parents of asthmatic children and the electronic values stored by the AirWatch device (PEFe. MATERIAL AND METHODS: Records of PEF measurements between October 1998 and 1999 were obtained from 42 asthmatic children 5 to 15 years of age recruited at the Hospital Infantil de Mexico Federico Gomez, in Mexico City. Parents recorded the maximum value in the health diary. Spearman correlation was calculated between PEFe and PEFr and a mixed-effects logistic model was used. RESULTS: The correlation between PEFe and PEFr was r=0.96 (p<0.05 among children with a diagnosis of moderate or severe asthma and r=0.40 (p<0.05 among children diagnosed with mild asthma. Follow-up time, asthma severity, gender and age of the child and their interactions were predictors of the differences between PEFe and PEFr. CONCLUSIONS: Parents of children with moderate or severe asthma from 6 to 8 years of age report PEF values with greater accuracy during follow-up than others.

  9. Knowledge, attitude and practice of physicians toward peak ...

    African Journals Online (AJOL)

    Background: Peak expiratory flow meter (PEFM) may reduce diagnostic delay and improve decision-making in asthma by providing an objective assessment of their flow and hence identify air flow variability that is essential for management of air way diseases. Objectives: This study was designed to reveal extent of ...

  10. Upper limit of peak area

    International Nuclear Information System (INIS)

    Helene, O.A.M.

    1982-08-01

    The determination of the upper limit of peak area in a multi-channel spectra, with a known significance level is discussed. This problem is specially important when the peak area is masked by the background statistical fluctuations. The problem is exactly solved and, thus, the results are valid in experiments with small number of events. The results are submitted to a Monte Carlo test and applied to the 92 Nb beta decay. (Author) [pt

  11. Peak Oil and other threatening peaks-Chimeras without substance

    International Nuclear Information System (INIS)

    Radetzki, Marian

    2010-01-01

    The Peak Oil movement has widely spread its message about an impending peak in global oil production, caused by an inadequate resource base. On closer scrutiny, the underlying analysis is inconsistent, void of a theoretical foundation and without support in empirical observations. Global oil resources are huge and expanding, and pose no threat to continuing output growth within an extended time horizon. In contrast, temporary or prolonged supply crunches are indeed plausible, even likely, on account of growing resource nationalism denying access to efficient exploitation of the existing resource wealth.

  12. Electricity Portfolio Management: Optimal Peak / Off-Peak Allocations

    OpenAIRE

    Huisman, Ronald; Mahieu, Ronald; Schlichter, Felix

    2007-01-01

    textabstractElectricity purchasers manage a portfolio of contracts in order to purchase the expected future electricity consumption profile of a company or a pool of clients. This paper proposes a mean-variance framework to address the concept of structuring the portfolio and focuses on how to allocate optimal positions in peak and off-peak forward contracts. It is shown that the optimal allocations are based on the difference in risk premiums per unit of day-ahead risk as a measure of relati...

  13. Ultrasonic Transducer Peak-to-Peak Optical Measurement

    Directory of Open Access Journals (Sweden)

    Pavel Skarvada

    2012-01-01

    Full Text Available Possible optical setups for measurement of the peak-to-peak value of an ultrasonic transducer are described in this work. The Michelson interferometer with the calibrated nanopositioner in reference path and laser Doppler vibrometer were used for the basic measurement of vibration displacement. Langevin type of ultrasonic transducer is used for the purposes of Electro-Ultrasonic Nonlinear Spectroscopy (EUNS. Parameters of produced mechanical vibration have to been well known for EUNS. Moreover, a monitoring of mechanical vibration frequency shift with a mass load and sample-transducer coupling is important for EUNS measurement.

  14. Peaking-factor of PWR

    International Nuclear Information System (INIS)

    Morioka, Noboru; Kato, Yasuji; Yokoi, M.

    1975-01-01

    Output peaking factor often plays an important role in the safety and operation of nuclear reactors. The meaning of the peaking factor of PWRs is categorized into two features or the peaking factor in core (FQ-core) and the peaking factor on the basis of accident analysis (or FQ-limit). FQ-core is the actual peaking factor realized in nuclear core at the time of normal operation, and FQ-limit should be evaluated from loss of coolant accident and other abnormal conditions. If FQ-core is lower than FQ-limit, the reactor may be operated at full load, but if FQ-core is larger than FQ-limit, reactor output should be controlled lower than FQ-limit. FQ-core has two kinds of values, or the one on the basis of nuclear design, and the other actually measured in reactor operation. The first FQ-core should be named as FQ-core-design and the latter as FQ-core-measured. The numerical evaluation of FQ-core-design is as follows; FQ-core-design of three-dimensions is synthesized with FQ-core horizontal value (X-Y) and FQ-core vertical value, the former one is calculated with ASSY-CORE code, and the latter one with one dimensional diffusion code. For the evaluation of FQ-core-measured, on-site data observation from nuclear reactor instrumentation or off-site data observation is used. (Iwase, T.)

  15. Peak effect in twinned superconductors

    International Nuclear Information System (INIS)

    Larkin, A.I.; Marchetti, M.C.; Vinokur, V.M.

    1995-01-01

    A sharp maximum in the critical current J c as a function of temperature just below the melting point of the Abrikosov flux lattice has recently been observed in both low- and high-temperature superconductors. This peak effect is strongest in twinned crystals for fields aligned with the twin planes. We propose that this peak signals the breakdown of the collective pinning regime and the crossover to strong pinning of single vortices on the twin boundaries. This crossover is very sharp and can account for the steep drop of the differential resistivity observed in experiments. copyright 1995 The American Physical Society

  16. Peak capacity and peak capacity per unit time in capillary and microchip zone electrophoresis.

    Science.gov (United States)

    Foley, Joe P; Blackney, Donna M; Ennis, Erin J

    2017-11-10

    peak capacity per unit time is a simple function of the upper bound, but its direct application is limited to samples with analytes whose electrophoretic mobilities can be varied independently of electroosmotic flow. For samples containing both co- and counter-electroosmotic ions whose electrophoretic mobilities cannot be easily manipulated, comparable levels of peak capacity and peak capacity per unit time for all ions can be obtained by adjusting the EOF to devote the same amount of time to the separation of each class of ions; this corresponds to μ r,Z =-0.5. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Hubbert's Peak -- A Physicist's View

    Science.gov (United States)

    McDonald, Richard

    2011-04-01

    Oil, as used in agriculture and transportation, is the lifeblood of modern society. It is finite in quantity and will someday be exhausted. In 1956, Hubbert proposed a theory of resource production and applied it successfully to predict peak U.S. oil production in 1970. Bartlett extended this work in publications and lectures on the finite nature of oil and its production peak and depletion. Both Hubbert and Bartlett place peak world oil production at a similar time, essentially now. Central to these analyses are estimates of total ``oil in place'' obtained from engineering studies of oil reservoirs as this quantity determines the area under the Hubbert's Peak. Knowing the production history and the total oil in place allows us to make estimates of reserves, and therefore future oil availability. We will then examine reserves data for various countries, in particular OPEC countries, and see if these data tell us anything about the future availability of oil. Finally, we will comment on synthetic oil and the possibility of carbon-neutral synthetic oil for a sustainable future.

  18. The dislocation-internal friction peak γ in tantalum

    International Nuclear Information System (INIS)

    Baur, J.; Benoit, W.; Schultz, H.

    1989-01-01

    Torsion-pendulum measurements were carried out on high-purity single crystal specimens of tantalum, having extremely low oxygen contents ( 2 peak, which appears close to γ is small traces of oxygen are presents. The γ 2 peak was formerly explained as a ''dislocation-enhanced Snoek peak''. The γ peak recovers at the peak temperature, whereas the γ 2 peak is more stable. On the basis of their results, and making use of earlier investigations of Rodrian and Schultz, the authors suggest that γ 2 is modified γ relaxation, related to screw-dislocation segments, stabilized by oxygen-decorated kinks. The stability of the γ 2 peak allows an accurate determination of the activation energy, found to be 1.00 +- 0.03 eV. This value is distinctly lower than the activation energy of the oxygen Snoek effect (1.10 eV) and is related here to the mechanism of ''kink-pair formation'' in screw dislocations, as the original γ peak. The numerical value is compatible with recent values derived from flow-stress measurements. The peak γ 2 shows increasing stability with increasing oxygen content. This is explained by single- and multi-decorated kinks

  19. SPANISH PEAKS PRIMITIVE AREA, MONTANA.

    Science.gov (United States)

    Calkins, James A.; Pattee, Eldon C.

    1984-01-01

    A mineral survey of the Spanish Peaks Primitive Area, Montana, disclosed a small low-grade deposit of demonstrated chromite and asbestos resources. The chances for discovery of additional chrome resources are uncertain and the area has little promise for the occurrence of other mineral or energy resources. A reevaluation, sampling at depth, and testing for possible extensions of the Table Mountain asbestos and chromium deposit should be undertaken in the light of recent interpretations regarding its geologic setting.

  20. Neurofeedback training for peak performance

    OpenAIRE

    Marek Graczyk; Maria Pąchalska; Artur Ziółkowski; Grzegorz Mańko; Beata Łukaszewska; Kazimierz Kochanowicz; Andrzej Mirski; Iurii D. Kropotov

    2014-01-01

    [b]aim[/b]. One of the applications of the Neurofeedback methodology is peak performance in sport. The protocols of the neurofeedback are usually based on an assessment of the spectral parameters of spontaneous EEG in resting state conditions. The aim of the paper was to study whether the intensive neurofeedback training of a well-functioning Olympic athlete who has lost his performance confidence after injury in sport, could change the brain functioning reflected in changes in spontaneou...

  1. Power peaking nuclear reliability factors

    International Nuclear Information System (INIS)

    Hassan, H.A.; Pegram, J.W.; Mays, C.W.; Romano, J.J.; Woods, J.J.; Warren, H.D.

    1977-11-01

    The Calculational Nuclear Reliability Factor (CNRF) assigned to the limiting power density calculated in reactor design has been determined. The CNRF is presented as a function of the relative power density of the fuel assembly and its radial local. In addition, the Measurement Nuclear Reliability Factor (MNRF) for the measured peak hot pellet power in the core has been evaluated. This MNRF is also presented as a function of the relative power density and radial local within the fuel assembly

  2. Evaluation of concurrent peak responses

    International Nuclear Information System (INIS)

    Wang, P.C.; Curreri, J.; Reich, M.

    1983-01-01

    This report deals with the problem of combining two or more concurrent responses which are induced by dynamic loads acting on nuclear power plant structures. Specifically, the acceptability of using the square root of the sum of the squares (SRSS) value of peak values as the combined response is investigated. Emphasis is placed on the establishment of a simplified criterion that is convenient and relatively easy to use by design engineers

  3. Finding two-dimensional peaks

    International Nuclear Information System (INIS)

    Silagadze, Z.K.

    2007-01-01

    Two-dimensional generalization of the original peak finding algorithm suggested earlier is given. The ideology of the algorithm emerged from the well-known quantum mechanical tunneling property which enables small bodies to penetrate through narrow potential barriers. We merge this 'quantum' ideology with the philosophy of Particle Swarm Optimization to get the global optimization algorithm which can be called Quantum Swarm Optimization. The functionality of the newborn algorithm is tested on some benchmark optimization problems

  4. Drivers of peak sales for pharmaceutical brands

    NARCIS (Netherlands)

    Fischer, Marc; Leeflang, Peter S. H.; Verhoef, Peter C.

    2010-01-01

    Peak sales are an important metric in the pharmaceutical industry. Specifically, managers are focused on the height-of-peak-sales and the time required achieving peak sales. We analyze how order of entry and quality affect the level of peak sales and the time-to-peak-sales of pharmaceutical brands.

  5. Spatial peak-load pricing

    International Nuclear Information System (INIS)

    Arellano, M. Soledad; Serra, Pablo

    2007-01-01

    This article extends the traditional electricity peak-load pricing model to include transmission costs. In the context of a two-node, two-technology electric power system, where suppliers face inelastic demand, we show that when the marginal plant is located at the energy-importing center, generators located away from that center should pay the marginal capacity transmission cost; otherwise, consumers should bear this cost through capacity payments. Since electric power transmission is a natural monopoly, marginal-cost pricing does not fully cover costs. We propose distributing the revenue deficit among users in proportion to the surplus they derive from the service priced at marginal cost. (Author)

  6. Economic effects of peak oil

    International Nuclear Information System (INIS)

    Lutz, Christian; Lehr, Ulrike; Wiebe, Kirsten S.

    2012-01-01

    Assuming that global oil production peaked, this paper uses scenario analysis to show the economic effects of a possible supply shortage and corresponding rise in oil prices in the next decade on different sectors in Germany and other major economies such as the US, Japan, China, the OPEC or Russia. Due to the price-inelasticity of oil demand the supply shortage leads to a sharp increase in oil prices in the second scenario, with high effects on GDP comparable to the magnitude of the global financial crises in 2008/09. Oil exporting countries benefit from high oil prices, whereas oil importing countries are negatively affected. Generally, the effects in the third scenario are significantly smaller than in the second, showing that energy efficiency measures and the switch to renewable energy sources decreases the countries' dependence on oil imports and hence reduces their vulnerability to oil price shocks on the world market. - Highlights: ► National and sectoral economic effects of peak oil until 2020 are modelled. ► The price elasticity of oil demand is low resulting in high price fluctuations. ► Oil shortage strongly affects transport and indirectly all other sectors. ► Global macroeconomic effects are comparable to the 2008/2009 crisis. ► Country effects depend on oil imports and productivity, and economic structures.

  7. “Avaliação da qualidade de vida e peak flow nasal em pós-operatório de cirurgias funcionais (turbinectomia e/ou septoplastia em pacientes com obstrução nasal crônica"

    Directory of Open Access Journals (Sweden)

    Filipe Braz

    2015-10-01

    Full Text Available A prevalência da obstrução nasal vem crescendo nos últimos anos. A obstrução nasal tem como causa etiológica uma série de patologias as mais comuns são: polipose nasal, rinossinusites, doenças metabólicas, defeito septal, corpos estranhos, tumores.   Pacientes que sofrem de obstrução nasal além de possuírem os sintomas clássicos de coriza, distúrbios do olfato, apresentam também uma perda significativa na qualidade de vida, uma vez que a acarreta alterações nas atividades cotidianas como: insônia e ronco noturno e apneia, dificuldade na prática de exercício físico.     O trabalho visa mensurar o quanto as cirurgias funcionais nasais melhoram a qualidade de vida e a permeabilidade das vias aéreas superiores de pacientes com obstrução nasal, e se a melhora é apenas no pós operatório imediato ou se essa é a longo prazo.   Para tal objetivo, o estudo utilizará de duas ferramentas sendo uma delas uma escala objetiva e a outra subjetiva. A escala objetiva de uso será o peak flow nasal inspiratório, aparelho capaz de avaliar a permeabilidade das vias aéreas proximais, sendo assim capaz de mensurar o grau da obstrução nasal. Já a escala subjetiva de escolha é Nasal Obstruction Syndrome Evaluation (NOSEscale, sendo hoje uma referência para estudos que visam avaliar a obstrução nasal sobre a qualidade de vida e comparar o pré e pós de tratamentos clínicos e cirúrgicos.   Realizada a analise dos 30 pacientes, a cirurgia funcional nasal se mostrou muito benéfica revelando uma melhora na escala NOSE de 76% e no Peak Flow de 65%. O estudo tem como objetivo secundário comparar a evolução dos pacientes no primeiro e no sexto mês de pós operatório. Os pacientes apresentaram uma melhora de 18% no NOSE e de 8% no Peak Flow, revelando uma melhora no pós-operatório mais tardio. Em relação à melhora dos pacientes após o ato cirúrgico, notamos que nenhum dos pacientes passa a apresentar um peak flow

  8. CALIBRACIÓN E IMPLEMENTACIÓN DEL MODELO MG PARA LA ESTIMACIÓN DE CAUDALES MÁXIMOS EN COLOMBIA CALIBRAÇÃO E IMPLEMENTAÇÃO DO MODELO MG PARA A ESTIMATIVA DE CAUDAIS MÁXIMOS NA COLÔMBIA CALIBRATION AND IMPLEMENTATION OF MG MODEL FOR ESTIMATING PEAK FLOWS IN COLOMBIA

    Directory of Open Access Journals (Sweden)

    Andrés Felipe Duque

    2010-12-01

    Full Text Available El propósito de este trabajo es calibrar un modelo para la estimación de caudales máximos que se adapte a las características hidrológicas, geomorfológicas y de cobertura vegetal de las cuencas colombianas. Por esta razón, se calibraron los parámetros del modelo probabilístico MG para todo el territorio colombiano, sus principales regiones geográficas y subregiones hidrológicamente homogéneas. Para la obtención de las ecuaciones analíticas del modelo MG se utilizaron los registros históricos de caudales máximos de 277 estaciones limnigráficas distribuidas a lo largo del territorio colombiano. Los resultados obtenidos aplicando el modelo MG calibrado y otros métodos comúnmente utilizados con el mismo propósito fueron comparados entre sí y se encontraron valores muy semejantes. El modelo MG calibrado en este trabajo se muestra como una opción viable para la estimación de caudales máximos en cuencas con información escasa en Colombia.O propósito deste trabalho é calibrar um modelo para a estimativa de caudais máximos que se adapte às características hidrológicas, geomorfológicas e de cobertura vegetal das bacias colombianas. Por esta razão, se calibraram os parâmetros do modelo probabilístico MG para todo o território colombiano, suas principais regiões geográficas e sub-regiões hidrologicamente homogêneas. Para a obtenção das equações analíticas do modelo MG se utilizaram os registros históricos de caudais máximos de 277 estações limnigráficas distribuídas ao longo do território colombiano. Os resultados obtidos aplicando o MG calibrado e outros métodos comumente utilizados com o mesmo propósito foram comparados entre si e se encontraram valores muito semelhantes. O modelo MG calibrado neste trabalho se amostra como uma opção viável para a estimativa de caudais máximos em bacias com informação escassa na Colômbia.The purpose of this paper is calibrate a model for estimating peak flows

  9. Knowledge, attitude and practice of nurses toward peak expiratory ...

    African Journals Online (AJOL)

    Background: Peak expiratory flow meter (PEFM) is an easy to use, relatively cheap device that can be used for guiding management of bronchial asthma by the patients at home according to a preset plan by health care workers. Objective: The aim of the study is to reveal the extent of knowledge and perception of nurses ...

  10. Family practitioners perception of, knowledge about and use of peak ...

    African Journals Online (AJOL)

    Background The purpose of this paper was to determine the availability of peak flow meters, perceptions about their usefulness and the perceptions of clinical indications for their use. Methods A questionnaire was administered to private and public sector practitioners (n=72) working in three urban areas of greater ...

  11. IDENTIFICATIONS PEAK HOURS ON INTERSECTIONS SET IN BIELSKO-BIAŁA CITY

    Directory of Open Access Journals (Sweden)

    Marcin KŁOS

    2016-03-01

    Full Text Available Traffic flow in cities is usually examined locally. This method is not effective for through traffic analysis. The paper discusses the problem of determining peak traffic hours taking into account vehicle distributions. Peak hours represent time periods of traffic flow which demand special treatment by traffic control systems. This is particularly important in the case of ITS. High values of traffic flow require relieving actions not only at the junctions but preferably along the transit routes. The north-south transit route in Bielsko-Biała was chosen for analysis. Instead of the usual two distinct peaks it is determined that the traffic flow is characterised by five peaks. This pattern is the result of specific location of the route, which links residential areas, industrial zones and shopping centres besides carrying through traffic. This multi peak graph more accurately models the traffic flow.

  12. 16 reference population equations using peak expiratory flow meters

    African Journals Online (AJOL)

    DR. AMINU

    Many formulae for predicting lung function values for Nigerians have been produced by a lot of investigators. The same principle ... equations in current use are based on linear statistical models which are subject to change and they did not express the .... that present lower limits of normal or present information from which ...

  13. 16 reference population equations using peak expiratory flow meters

    African Journals Online (AJOL)

    DR. AMINU

    equations in current use are based on linear statistical models which are subject to change and they did not ... assess risks of surgery and to assist in evaluations performed ... identify and quantify pulmonary involvement incases of asthma.

  14. Reference population equations using peak expiratory flow meters ...

    African Journals Online (AJOL)

    Many formulae for predicting lung function values for Nigerians have been produced by a lot of investigators. The same principle but different statistical methods were adopted by different authors in generating these equations, hence the variability observed among these formulae. Most equations in current use are based on ...

  15. C/NOFS Satellite Electric Field and Plasma Density Observations of Plasma Instabilities Below the Equatorial F-Peak -- Evidence for Approximately 500 km-Scale Spread-F "Precursor" Waves Driven by Zonal Shear Flow and km-Scale, Narrow-Banded Irregularities

    Science.gov (United States)

    Pfaff, R.; Freudenreich, H.; Klenzing, J.; Liebrecht, C.; Valladares, C.

    2011-01-01

    As solar activity has increased, the ionosphere F-peak has been elevated on numerous occasions above the C/NOFS satellite perigee of 400km. In particular, during the month of April, 2011, the satellite consistently journeyed below the F-peak whenever the orbit was in the region of the South Atlantic anomaly after sunset. During these passes, data from the electric field and plasma density probes on the satellite have revealed two types of instabilities which had not previously been observed in the C/NOFS data set (to our knowledge): The first is evidence for 400-500km-scale bottomside "undulations" that appear in the density and electric field data. In one case, these large scale waves are associated with a strong shear in the zonal E x B flow, as evidenced by variations in the meridional (outward) electric fields observed above and below the F-peak. These undulations are devoid of smaller scale structures in the early evening, yet appear at later local times along the same orbit associated with fully-developed spread-F with smaller scale structures. This suggests that they may be precursor waves for spread-F, driven by a collisional shear instability, following ideas advanced previously by researchers using data from the Jicamarca radar. A second new result (for C/NOFS) is the appearance of km-scale irregularities that are a common feature in the electric field and plasma density data that also appear when the satellite is below the F -peak at night. The vector electric field instrument on C/NOFS clearly shows that the electric field component of these waves is strongest in the zonal direction. These waves are strongly correlated with simultaneous observations of plasma density oscillations and appear both with, and without, evidence of larger-scale spread-F depletions. These km-scale, quasi-coherent waves strongly resemble the bottomside, sinusoidal irregularities reported in the Atmosphere Explorer satellite data set by Valladares et al. [JGR, 88, 8025, 1983

  16. Establishment of peak bone mass.

    Science.gov (United States)

    Mora, Stefano; Gilsanz, Vicente

    2003-03-01

    Among the main areas of progress in osteoporosis research during the last decade or so are the general recognition that this condition, which is the cause of so much pain in the elderly population, has its antecedents in childhood and the identification of the structural basis accounting for much of the differences in bone strength among humans. Nevertheless, current understanding of the bone mineral accrual process is far from complete. The search for genes that regulate bone mass acquisition is ongoing, and current results are not sufficient to identify subjects at risk. However, there is solid evidence that BMD measurements can be helpful for the selection of subjects that presumably would benefit from preventive interventions. The questions regarding the type of preventive interventions, their magnitude, and duration remain unanswered. Carefully designed controlled trials are needed. Nevertheless, previous experience indicates that weight-bearing activity and possibly calcium supplements are beneficial if they are begun during childhood and preferably before the onset of puberty. Modification of unhealthy lifestyles and increments in exercise or calcium assumption are logical interventions that should be implemented to improve bone mass gains in all children and adolescents who are at risk of failing to achieve an optimal peak bone mass.

  17. Neurofeedback training for peak performance

    Directory of Open Access Journals (Sweden)

    Marek Graczyk

    2014-11-01

    Full Text Available [b]aim[/b]. One of the applications of the Neurofeedback methodology is peak performance in sport. The protocols of the neurofeedback are usually based on an assessment of the spectral parameters of spontaneous EEG in resting state conditions. The aim of the paper was to study whether the intensive neurofeedback training of a well-functioning Olympic athlete who has lost his performance confidence after injury in sport, could change the brain functioning reflected in changes in spontaneous EEG and event related potentials (ERPs. [b]case study[/b]. The case is presented of an Olympic athlete who has lost his performance confidence after injury in sport. He wanted to resume his activities by means of neurofeedback training. His QEEG/ERP parameters were assessed before and after 4 intensive sessions of neurotherapy. Dramatic and statistically significant changes that could not be explained by error measurement were observed in the patient. [b]conclusion[/b]. Neurofeedback training in the subject under study increased the amplitude of the monitoring component of ERPs generated in the anterior cingulate cortex, accompanied by an increase in beta activity over the medial prefrontal cortex. Taking these changes together, it can be concluded that that even a few sessions of neurofeedback in a high performance brain can significantly activate the prefrontal cortical areas associated with increasing confidence in sport performance.

  18. Reactor power peaking information display

    International Nuclear Information System (INIS)

    Book, T.L.; Kochendarfer, R.A.

    1986-01-01

    This patent describes a system for monitoring operating conditions within a nuclear reactor. The system consists of a method for measuring the operating parameters within the nuclear reactor, including the position of axial power shaping rods and regulating control rod. It also includes a method for determining from the operating parameters the operating limits before a power peaking condition exists within the nuclear reactor, and a method for displaying the operating limits which consists of a visual display permitting the continuous monitoring of the operating conditions within the nuclear reactor as a graph of the shaping rod position vs the regulating rod position having a permissible area and a restricted area. The permissible area is further divided into a recommended operating area for steady state operation and a cursor located on the graph to indicate the present operating condition of the nuclear reactor to allow an operator to view any need for corrective action based on the movement of the cursor out of the recommended operating area and to take any corrective transient action within the permissible area

  19. Neurofeedback training for peak performance.

    Science.gov (United States)

    Graczyk, Marek; Pąchalska, Maria; Ziółkowski, Artur; Mańko, Grzegorz; Łukaszewska, Beata; Kochanowicz, Kazimierz; Mirski, Andrzej; Kropotov, Iurii D

    2014-01-01

    One of the applications of the Neurofeedback methodology is peak performance in sport. The protocols of the neurofeedback are usually based on an assessment of the spectral parameters of spontaneous EEG in resting state conditions. The aim of the paper was to study whether the intensive neurofeedback training of a well-functioning Olympic athlete who has lost his performance confidence after injury in sport, could change the brain functioning reflected in changes in spontaneous EEG and event related potentials (ERPs). The case is presented of an Olympic athlete who has lost his performance confidence after injury in sport. He wanted to resume his activities by means of neurofeedback training. His QEEG/ERP parameters were assessed before and after 4 intensive sessions of neurotherapy. Dramatic and statistically significant changes that could not be explained by error measurement were observed in the patient. Neurofeedback training in the subject under study increased the amplitude of the monitoring component of ERPs generated in the anterior cingulate cortex, accompanied by an increase in beta activity over the medial prefrontal cortex. Taking these changes together, it can be concluded that that even a few sessions of neurofeedback in a high performance brain can significantly activate the prefrontal cortical areas associated with increasing confidence in sport performance.

  20. Group Elevator Peak Scheduling Based on Robust Optimization Model

    Directory of Open Access Journals (Sweden)

    ZHANG, J.

    2013-08-01

    Full Text Available Scheduling of Elevator Group Control System (EGCS is a typical combinatorial optimization problem. Uncertain group scheduling under peak traffic flows has become a research focus and difficulty recently. RO (Robust Optimization method is a novel and effective way to deal with uncertain scheduling problem. In this paper, a peak scheduling method based on RO model for multi-elevator system is proposed. The method is immune to the uncertainty of peak traffic flows, optimal scheduling is realized without getting exact numbers of each calling floor's waiting passengers. Specifically, energy-saving oriented multi-objective scheduling price is proposed, RO uncertain peak scheduling model is built to minimize the price. Because RO uncertain model could not be solved directly, RO uncertain model is transformed to RO certain model by elevator scheduling robust counterparts. Because solution space of elevator scheduling is enormous, to solve RO certain model in short time, ant colony solving algorithm for elevator scheduling is proposed. Based on the algorithm, optimal scheduling solutions are found quickly, and group elevators are scheduled according to the solutions. Simulation results show the method could improve scheduling performances effectively in peak pattern. Group elevators' efficient operation is realized by the RO scheduling method.

  1. On dealing with multiple correlation peaks in PIV

    Science.gov (United States)

    Masullo, A.; Theunissen, R.

    2018-05-01

    A novel algorithm to analyse PIV images in the presence of strong in-plane displacement gradients and reduce sub-grid filtering is proposed in this paper. Interrogation windows subjected to strong in-plane displacement gradients often produce correlation maps presenting multiple peaks. Standard multi-grid procedures discard such ambiguous correlation windows using a signal to noise (SNR) filter. The proposed algorithm improves the standard multi-grid algorithm allowing the detection of splintered peaks in a correlation map through an automatic threshold, producing multiple displacement vectors for each correlation area. Vector locations are chosen by translating images according to the peak displacements and by selecting the areas with the strongest match. The method is assessed on synthetic images of a boundary layer of varying intensity and a sinusoidal displacement field of changing wavelength. An experimental case of a flow exhibiting strong velocity gradients is also provided to show the improvements brought by this technique.

  2. Passive radio frequency peak power multiplier

    Science.gov (United States)

    Farkas, Zoltan D.; Wilson, Perry B.

    1977-01-01

    Peak power multiplication of a radio frequency source by simultaneous charging of two high-Q resonant microwave cavities by applying the source output through a directional coupler to the cavities and then reversing the phase of the source power to the coupler, thereby permitting the power in the cavities to simultaneously discharge through the coupler to the load in combination with power from the source to apply a peak power to the load that is a multiplication of the source peak power.

  3. Practical load management - Peak shaving using photovoltaics

    International Nuclear Information System (INIS)

    Berger, W.

    2009-01-01

    This article takes a look at how photovoltaic (PV) power generation can be used in a practical way to meet peak demands for electricity. Advice is provided on how photovoltaics can provide peak load 'shaving' through the correlation between its production and the peak loads encountered during the day. The situation regarding feed-in tariffs in Italy is discussed, as are further examples of installations in Germany and Austria. Further, an initiative of the American Southern California Edison utility is discussed which foresees the installation of large PV plant on the roofs of commercial premises to provide local generation of peak energy and thus relieve demands on their power transportation network.

  4. [A peak recognition algorithm designed for chromatographic peaks of transformer oil].

    Science.gov (United States)

    Ou, Linjun; Cao, Jian

    2014-09-01

    In the field of the chromatographic peak identification of the transformer oil, the traditional first-order derivative requires slope threshold to achieve peak identification. In terms of its shortcomings of low automation and easy distortion, the first-order derivative method was improved by applying the moving average iterative method and the normalized analysis techniques to identify the peaks. Accurate identification of the chromatographic peaks was realized through using multiple iterations of the moving average of signal curves and square wave curves to determine the optimal value of the normalized peak identification parameters, combined with the absolute peak retention times and peak window. The experimental results show that this algorithm can accurately identify the peaks and is not sensitive to the noise, the chromatographic peak width or the peak shape changes. It has strong adaptability to meet the on-site requirements of online monitoring devices of dissolved gases in transformer oil.

  5. [Study of personal best value of peak expiratory flow in patients with asthma--comparison of the highest value of daily PEF under good control and the highest value of daily PEF obtained after using repeated inhaled beta2-agonist during high-dose inhaled steroid treatment].

    Science.gov (United States)

    Watanabe, Naoto; Makino, Sohei; Kihara, Norio; Fukuda, Takeshi

    2008-12-01

    In the guideline for asthma management, it is important to find the personal best value of peak expiratory flow (best PEF). Recently, we have substituted the highest value of PEF in daily life under good control (daily highest PEF) for the best PEF. In the present study, we considered whether the daily highest PEF could be used as the best PEF or not. Subjects were 30 asthmatics who were well controlled but whose baseline PEF values were less than 80 percent of predicted values. We compared the daily highest PEF and the highest of PEF obtained after repeated inhaled beta2-agonist (salbutamol MDI every 20 minutes three times). All subjects then received 1600 microg/day of beclomethasone dipropionate (BDP) for 4 to 8 weeks. We studied the effect of high-dose inhaled steroid treatment on each PEF value and compared the daily highest PEF and the highest PEF obtained after using repeated salbutamol MDI during high dose inhaled steroid therapy on the examination day again. The baseline PEF, daily highest PEF and the highest PEF obtained after salbutamol MDI were significantly less than the each values obtained after high-dose BDP. The best PEF value of them was the value obtained after repeated salbutamol MDI during high dose BDP. We suggest that the daily highest PEF under good control is not a substitute for best PEF because it changes according to the degree of improvement of airway inflammation. We recommend that a course of high dose inhaled steroid is effective in finding the best value of PEF for each individual with moderate asthma.

  6. Employer Attitudes towards Peak Hour Avoidance

    NARCIS (Netherlands)

    Vonk Noordegraaf, D.M.; Annema, J.A.

    2012-01-01

    Peak Hour Avoidance is a relatively new Dutch mobility management measure. To reduce congestion frequent car drivers are given a financial reward for reducing the proportion of trips that they make during peak hours on a specific motorway section. Although previous studies show that employers are

  7. Employer attitudes towards peak hour avoidance

    NARCIS (Netherlands)

    Noordegraaf, D.M.V.; Annema, J.A.

    2012-01-01

    Peak Hour Avoidance is a relatively new Dutch mobility management measure. To reduce congestion frequent car drivers are given a financial reward for reducing the proportion of trips that they make during peak hours on a specific motorway section. Although previous studies show that employers are

  8. Peak load pricing lowers generation costs

    International Nuclear Information System (INIS)

    Lande, R.H.

    1980-01-01

    Before a utility implements peak load pricing for different classes of consumers, the costs and the benefits should be compared. The methodology described enables a utility to determine whether peak load pricing should be introduced for specific users. Cost-benefit analyses for domestic consumers and commercial/industrial consumers, showing break-even points are presented. (author)

  9. Peak Shaving Considering Streamflow Uncertainties | Iwuagwu ...

    African Journals Online (AJOL)

    The main thrust of this paper is peak shaving with a Stochastic hydro model. In peak sharing, the amount of hydro energy scheduled may be a minimum but it serves to replace less efficient thermal units. The sample system is die Kainji hydro plant and the thermal units of the National Electric Power Authority. The random ...

  10. The peak in neutron powder diffraction

    International Nuclear Information System (INIS)

    Laar, B. van; Yelon, W.B.

    1984-01-01

    For the application of Rietveld profile analysis to neutron powder diffraction data a precise knowledge of the peak profile, in both shape and position, is required. The method now in use employs a Gaussian shaped profile with a semi-empirical asymmetry correction for low-angle peaks. The integrated intensity is taken to be proportional to the classical Lorentz factor calculated for the X-ray case. In this paper an exact expression is given for the peak profile based upon the geometrical dimensions of the diffractometer. It is shown that the asymmetry of observed peaks is well reproduced by this expression. The angular displacement of the experimental profile with respect to the nominal Bragg angle value is larger than expected. Values for the correction to the classical Lorentz factor for the integrated intensity are given. The exact peak profile expression has been incorporated into a Rietveld profile analysis refinement program. (Auth.)

  11. Peak tree: a new tool for multiscale hierarchical representation and peak detection of mass spectrometry data.

    Science.gov (United States)

    Zhang, Peng; Li, Houqiang; Wang, Honghui; Wong, Stephen T C; Zhou, Xiaobo

    2011-01-01

    Peak detection is one of the most important steps in mass spectrometry (MS) analysis. However, the detection result is greatly affected by severe spectrum variations. Unfortunately, most current peak detection methods are neither flexible enough to revise false detection results nor robust enough to resist spectrum variations. To improve flexibility, we introduce peak tree to represent the peak information in MS spectra. Each tree node is a peak judgment on a range of scales, and each tree decomposition, as a set of nodes, is a candidate peak detection result. To improve robustness, we combine peak detection and common peak alignment into a closed-loop framework, which finds the optimal decomposition via both peak intensity and common peak information. The common peak information is derived and loopily refined from the density clustering of the latest peak detection result. Finally, we present an improved ant colony optimization biomarker selection method to build a whole MS analysis system. Experiment shows that our peak detection method can better resist spectrum variations and provide higher sensitivity and lower false detection rates than conventional methods. The benefits from our peak-tree-based system for MS disease analysis are also proved on real SELDI data.

  12. Multiscale peak detection in wavelet space.

    Science.gov (United States)

    Zhang, Zhi-Min; Tong, Xia; Peng, Ying; Ma, Pan; Zhang, Ming-Jin; Lu, Hong-Mei; Chen, Xiao-Qing; Liang, Yi-Zeng

    2015-12-07

    Accurate peak detection is essential for analyzing high-throughput datasets generated by analytical instruments. Derivatives with noise reduction and matched filtration are frequently used, but they are sensitive to baseline variations, random noise and deviations in the peak shape. A continuous wavelet transform (CWT)-based method is more practical and popular in this situation, which can increase the accuracy and reliability by identifying peaks across scales in wavelet space and implicitly removing noise as well as the baseline. However, its computational load is relatively high and the estimated features of peaks may not be accurate in the case of peaks that are overlapping, dense or weak. In this study, we present multi-scale peak detection (MSPD) by taking full advantage of additional information in wavelet space including ridges, valleys, and zero-crossings. It can achieve a high accuracy by thresholding each detected peak with the maximum of its ridge. It has been comprehensively evaluated with MALDI-TOF spectra in proteomics, the CAMDA 2006 SELDI dataset as well as the Romanian database of Raman spectra, which is particularly suitable for detecting peaks in high-throughput analytical signals. Receiver operating characteristic (ROC) curves show that MSPD can detect more true peaks while keeping the false discovery rate lower than MassSpecWavelet and MALDIquant methods. Superior results in Raman spectra suggest that MSPD seems to be a more universal method for peak detection. MSPD has been designed and implemented efficiently in Python and Cython. It is available as an open source package at .

  13. Isotope resolution of the iron peak

    International Nuclear Information System (INIS)

    Henke, R.P.; Benton, E.V.

    1977-01-01

    A stack of Lexan detectors from the Apollo 17 mission has been analyzed to obtain Z measurements of sufficient accuracy to resolve the iron peak into its isotopic components. Within this distribution several peaks are present. With the centrally located, most populated peak assumed to be 56 Fe, the measurements imply that the abundances of 54 Fe and 58 Fe are appreciable fractions of the 56 Fe abundance. This result is in agreement with those of Webber et al. and Siegman et al. but in disagreement with the predictions of Tsao et al. (Auth.)

  14. Peak load arrangements : Assessment of Nordel guidelines

    Energy Technology Data Exchange (ETDEWEB)

    2009-07-01

    Two Nordic countries, Sweden and Finland, have legislation that empowers the TSO to acquire designated peak load resources to mitigate the risk for shortage situations during the winter. In Denmark, the system operator procures resources to maintain a satisfactory level of security of supply. In Norway the TSO has set up a Regulation Power Option Market (RKOM) to secure a satisfactory level of operational reserves at all times, also in winter with high load demand. Only the arrangements in Finland and Sweden fall under the heading of Peak Load Arrangements defined in Nordel Guidelines. NordREG has been invited by the Electricity Market Group (EMG) to evaluate Nordel's proposal for 'Guidelines for transitional Peak Load Arrangements'. The EMG has also financed a study made by EC Group to support NordREG in the evaluation of the proposal. The study has been taken into account in NordREG's evaluation. In parallel to the EMG task, the Swedish regulator, the Energy Markets Inspectorate, has been given the task by the Swedish government to investigate a long term solution of the peak load issue. The Swedish and Finnish TSOs have together with Nord Pool Spot worked on finding a harmonized solution for activation of the peak load reserves in the market. An agreement accepted by the relevant authorities was reached in early January 2009, and the arrangement has been implemented since 19th January 2009. NordREG views that the proposed Nordel guidelines have served as a starting point for the presently agreed procedure. However, NordREG does not see any need to further develop the Nordel guidelines for peak load arrangements. NordREG agrees with Nordel that the market should be designed to solve peak load problems through proper incentives to market players. NordREG presumes that the relevant authorities in each country will take decisions on the need for any peak load arrangement to ensure security of supply. NordREG proposes that such decisions should be

  15. Automated Peak Picking and Peak Integration in Macromolecular NMR Spectra Using AUTOPSY

    Science.gov (United States)

    Koradi, Reto; Billeter, Martin; Engeli, Max; Güntert, Peter; Wüthrich, Kurt

    1998-12-01

    A new approach for automated peak picking of multidimensional protein NMR spectra with strong overlap is introduced, which makes use of the program AUTOPSY (automatedpeak picking for NMRspectroscopy). The main elements of this program are a novel function for local noise level calculation, the use of symmetry considerations, and the use of lineshapes extracted from well-separated peaks for resolving groups of strongly overlapping peaks. The algorithm generates peak lists with precise chemical shift and integral intensities, and a reliability measure for the recognition of each peak. The results of automated peak picking of NOESY spectra with AUTOPSY were tested in combination with the combined automated NOESY cross peak assignment and structure calculation routine NOAH implemented in the program DYANA. The quality of the resulting structures was found to be comparable with those from corresponding data obtained with manual peak picking.

  16. China's "Exported Carbon" Peak: Patterns, Drivers, and Implications

    Science.gov (United States)

    Mi, Zhifu; Meng, Jing; Green, Fergus; Coffman, D'Maris; Guan, Dabo

    2018-05-01

    Over the past decade, China has entered a "new normal" phase in economic development, with its role in global trade flows changing significantly. This study estimates the driving forces of Chinese export-embodied carbon emissions in the new normal phase, based on environmentally extended multiregional input-output modeling and structural decomposition analysis. We find that Chinese export-embodied CO2 emissions peaked in 2008 at a level of 1,657 million tones. The subsequent decline in CO2 emissions was mainly due to the changing structure of Chinese production. The peak in Chinese export-embodied emissions is encouraging from the perspective of global climate change mitigation, as it implies downward pressure on global CO2 emissions. However, more attention should focus on ensuring that countries that may partly replace China as major production bases increase their exports using low-carbon inputs.

  17. 76 FR 35215 - Notice of EPA Workshop on Sanitary Sewer Overflows and Peak Wet Weather Discharges

    Science.gov (United States)

    2011-06-16

    ... maintained sanitary sewer systems are meant to collect and transport all of the sewage that flows into them... sewage from these overflows can contaminate our waters, causing serious water quality problems. It can... influent flows to exceed the treatment capacity of existing secondary treatment units. Known as ``peak...

  18. Bayesian Peak Picking for NMR Spectra

    KAUST Repository

    Cheng, Yichen

    2014-02-01

    Protein structure determination is a very important topic in structural genomics, which helps people to understand varieties of biological functions such as protein-protein interactions, protein–DNA interactions and so on. Nowadays, nuclear magnetic resonance (NMR) has often been used to determine the three-dimensional structures of protein in vivo. This study aims to automate the peak picking step, the most important and tricky step in NMR structure determination. We propose to model the NMR spectrum by a mixture of bivariate Gaussian densities and use the stochastic approximation Monte Carlo algorithm as the computational tool to solve the problem. Under the Bayesian framework, the peak picking problem is casted as a variable selection problem. The proposed method can automatically distinguish true peaks from false ones without preprocessing the data. To the best of our knowledge, this is the first effort in the literature that tackles the peak picking problem for NMR spectrum data using Bayesian method.

  19. Peak-Seeking Control for Trim Optimization

    Data.gov (United States)

    National Aeronautics and Space Administration — Innovators have developed a peak-seeking algorithm that can reduce drag and improve performance and fuel efficiency by optimizing aircraft trim in real time. The...

  20. Limitation of peak fitting and peak shape methods for determination of activation energy of thermoluminescence glow peaks

    CERN Document Server

    Sunta, C M; Piters, T M; Watanabe, S

    1999-01-01

    This paper shows the limitation of general order peak fitting and peak shape methods for determining the activation energy of the thermoluminescence glow peaks in the cases in which retrapping probability is much higher than the recombination probability and the traps are filled up to near saturation level. Right values can be obtained when the trap occupancy is reduced by using small doses or by post-irradiation partial bleaching. This limitation in the application of these methods has not been indicated earlier. In view of the unknown nature of kinetics in the experimental samples, it is recommended that these methods of activation energy determination should be applied only at doses well below the saturation dose.

  1. Statistics of peaks of Gaussian random fields

    International Nuclear Information System (INIS)

    Bardeen, J.M.; Bond, J.R.; Kaiser, N.; Szalay, A.S.; Stanford Univ., CA; California Univ., Berkeley; Cambridge Univ., England; Fermi National Accelerator Lab., Batavia, IL)

    1986-01-01

    A set of new mathematical results on the theory of Gaussian random fields is presented, and the application of such calculations in cosmology to treat questions of structure formation from small-amplitude initial density fluctuations is addressed. The point process equation is discussed, giving the general formula for the average number density of peaks. The problem of the proper conditional probability constraints appropriate to maxima are examined using a one-dimensional illustration. The average density of maxima of a general three-dimensional Gaussian field is calculated as a function of heights of the maxima, and the average density of upcrossing points on density contour surfaces is computed. The number density of peaks subject to the constraint that the large-scale density field be fixed is determined and used to discuss the segregation of high peaks from the underlying mass distribution. The machinery to calculate n-point peak-peak correlation functions is determined, as are the shapes of the profiles about maxima. 67 references

  2. Peak Oil, threat or energy worlds' phantasm?

    International Nuclear Information System (INIS)

    Favennec, Jean-Pierre

    2011-01-01

    The concept of Peak Oil is based on the work of King Hubbert, a petroleum geologist who worked for Shell in the USA in the 1960's. Based on the fact that discoveries in America reached a maximum in the 1930's, he announced that American production would reach a maximum in 1969, which did actually occur. Geologists members of the Association for the Study of Peak Oil have extrapolated this result to a worldwide scale and, since oil discoveries reached a peak in the 1960's, argued that production will peak in the very near future. It is clear that hydrocarbon reserves are finite and therefore exhaustible. But little is known regarding the level of ultimate (i.e. total existing) reserves. There are probably very large reserves of non conventional oil in addition to the reserves of conventional oil. An increasing number of specialists put maximum production at less than 100 Mb/d more for geopolitical than physical reasons. Attainable peak production will probably vary from year to year and will depend on how crude oil prices develop

  3. Electric peak power forecasting by year 2025

    International Nuclear Information System (INIS)

    Alsayegh, O.A.; Al-Matar, O.A.; Fairouz, F.A.; Al-Mulla Ali, A.

    2005-01-01

    Peak power demand in Kuwait up to the year 2025 was predicted using an artificial neural network (ANN) model. The aim of the study was to investigate the effect of air conditioning (A/C) units on long-term power demand. Five socio-economic factors were selected as inputs for the simulation: (1) gross national product, (2) population, (3) number of buildings, (4) imports of A/C units, and (5) index of industrial production. The study used socio-economic data from 1978 to 2000. Historical data of the first 10 years of the studied time period were used to train the ANN. The electrical network was then simulated to forecast peak power for the following 11 years. The calculated error was then used for years in which power consumption data were not available. The study demonstrated that average peak power rates increased by 4100 MW every 5 years. Various scenarios related to changes in population, the number of buildings, and the quantity of A/C units were then modelled to estimate long-term peak power demand. Results of the study demonstrated that population had the strongest impact on future power demand, while the number of buildings had the smallest impact. It was concluded that peak power growth can be controlled through the use of different immigration policies, increased A/C efficiency, and the use of vertical housing. 7 refs., 2 tabs., 6 figs

  4. Electric peak power forecasting by year 2025

    Energy Technology Data Exchange (ETDEWEB)

    Alsayegh, O.A.; Al-Matar, O.A.; Fairouz, F.A.; Al-Mulla Ali, A. [Kuwait Inst. for Scientific Research, Kuwait City (Kuwait). Div. of Environment and Urban Development

    2005-07-01

    Peak power demand in Kuwait up to the year 2025 was predicted using an artificial neural network (ANN) model. The aim of the study was to investigate the effect of air conditioning (A/C) units on long-term power demand. Five socio-economic factors were selected as inputs for the simulation: (1) gross national product, (2) population, (3) number of buildings, (4) imports of A/C units, and (5) index of industrial production. The study used socio-economic data from 1978 to 2000. Historical data of the first 10 years of the studied time period were used to train the ANN. The electrical network was then simulated to forecast peak power for the following 11 years. The calculated error was then used for years in which power consumption data were not available. The study demonstrated that average peak power rates increased by 4100 MW every 5 years. Various scenarios related to changes in population, the number of buildings, and the quantity of A/C units were then modelled to estimate long-term peak power demand. Results of the study demonstrated that population had the strongest impact on future power demand, while the number of buildings had the smallest impact. It was concluded that peak power growth can be controlled through the use of different immigration policies, increased A/C efficiency, and the use of vertical housing. 7 refs., 2 tabs., 6 figs.

  5. SPANISH PEAKS WILDERNESS STUDY AREA, COLORADO.

    Science.gov (United States)

    Budding, Karin E.; Kluender, Steven E.

    1984-01-01

    A geologic and geochemical investigation and a survey of mines and prospects were conducted to evaluate the mineral-resource potential of the Spanish Peaks Wilderness Study Area, Huerfano and Las Animas Counties, in south-central Colorado. Anomalous gold, silver, copper, lead, and zinc concentrations in rocks and in stream sediments from drainage basins in the vicinity of the old mines and prospects on West Spanish Peak indicate a substantiated mineral-resource potential for base and precious metals in the area surrounding this peak; however, the mineralized veins are sparse, small in size, and generally low in grade. There is a possibility that coal may underlie the study area, but it would be at great depth and it is unlikely that it would have survived the intense igneous activity in the area. There is little likelihood for the occurrence of oil and gas because of the lack of structural traps and the igneous activity.

  6. Analysis of fuel end-temperature peaking

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Z.; Jiang, Q.; Lai, L.; Shams, M. [CANDU Energy Inc., Fuel Engineering Dept., Mississauga, Ontario (Canada)

    2013-07-01

    During normal operation and refuelling of CANDU® fuel, fuel temperatures near bundle ends will increase due to a phenomenon called end flux peaking. Similar phenomenon would also be expected to occur during a postulated large break LOCA event. The end flux peaking in a CANDU fuel element is due to the fact that neutron flux is higher near a bundle end, in contact with a neighbouring bundle or close to heavy water coolant, than in the bundle mid-plane, because of less absorption of thermal neutrons by Zircaloy or heavy water than by the UO{sub 2} material. This paper describes Candu Energy experience in analysing behaviour of bundle due to end flux peaking using fuel codes FEAT, ELESTRES and ELOCA. (author)

  7. Osteoporosis: Peak Bone Mass in Women

    Science.gov (United States)

    ... bone density are seen even during childhood and adolescence. Hormonal factors. The hormone estrogen has an effect on peak bone mass. For example, women who had their first menstrual cycle at an early age and those who use oral contraceptives, which contain estrogen, often have high bone mineral ...

  8. Facility Location with Double-peaked Preferences

    DEFF Research Database (Denmark)

    Filos-Ratsikas, Aris; Li, Minming; Zhang, Jie

    2015-01-01

    ; this makes the problem essentially more challenging. As our main contribution, we present a simple truthful-in-expectation mechanism that achieves an approximation ratio of 1+b=c for both the social and the maximum, cost, where b is the distance of the agent from the peak and c is the minimum cost...

  9. Robust Peak Recognition in Intracranial Pressure Signals

    Directory of Open Access Journals (Sweden)

    Bergsneider Marvin

    2010-10-01

    Full Text Available Abstract Background The waveform morphology of intracranial pressure pulses (ICP is an essential indicator for monitoring, and forecasting critical intracranial and cerebrovascular pathophysiological variations. While current ICP pulse analysis frameworks offer satisfying results on most of the pulses, we observed that the performance of several of them deteriorates significantly on abnormal, or simply more challenging pulses. Methods This paper provides two contributions to this problem. First, it introduces MOCAIP++, a generic ICP pulse processing framework that generalizes MOCAIP (Morphological Clustering and Analysis of ICP Pulse. Its strength is to integrate several peak recognition methods to describe ICP morphology, and to exploit different ICP features to improve peak recognition. Second, it investigates the effect of incorporating, automatically identified, challenging pulses into the training set of peak recognition models. Results Experiments on a large dataset of ICP signals, as well as on a representative collection of sampled challenging ICP pulses, demonstrate that both contributions are complementary and significantly improve peak recognition performance in clinical conditions. Conclusion The proposed framework allows to extract more reliable statistics about the ICP waveform morphology on challenging pulses to investigate the predictive power of these pulses on the condition of the patient.

  10. Liquid waste processing at Comanche Peak

    International Nuclear Information System (INIS)

    Hughes-Edwards, L.M.; Edwards, J.M.

    1996-01-01

    This article describes the radioactive waste processing at Comanche Peak Steam Electric Station. Topics covered are the following: Reduction of liquid radioactive discharges (system leakage, outage planning); reduction of waste resin generation (waste stream segregation, processing methodology); reduction of activity released and off-site dose. 8 figs., 2 tabs

  11. Avoiding the False Peaks in Correlation Discrimination

    International Nuclear Information System (INIS)

    Awwal, A.S.

    2009-01-01

    Fiducials imprinted on laser beams are used to perform video image based alignment of the 192 laser beams in the National Ignition Facility (NIF) of Lawrence Livermore National Laboratory. In many video images, matched filtering is used to detect the location of these fiducials. Generally, the highest correlation peak is used to determine the position of the fiducials. However, when the signal to-be-detected is very weak compared to the noise, this approach totally breaks down. The highest peaks act as traps for false detection. The active target images used for automatic alignment in the National Ignition Facility are examples of such images. In these images, the fiducials of interest exhibit extremely low intensity and contrast, surrounded by high intensity reflection from metallic objects. Consequently, the highest correlation peaks are caused by these bright objects. In this work, we show how the shape of the correlation is exploited to isolate the valid matches from hundreds of invalid correlation peaks, and therefore identify extremely faint fiducials under very challenging imaging conditions

  12. Hubbert's Peak: the Impending World oil Shortage

    Science.gov (United States)

    Deffeyes, K. S.

    2004-12-01

    Global oil production will probably reach a peak sometime during this decade. After the peak, the world's production of crude oil will fall, never to rise again. The world will not run out of energy, but developing alternative energy sources on a large scale will take at least 10 years. The slowdown in oil production may already be beginning; the current price fluctuations for crude oil and natural gas may be the preamble to a major crisis. In 1956, the geologist M. King Hubbert predicted that U.S. oil production would peak in the early 1970s.1 Almost everyone, inside and outside the oil industry, rejected Hubbert's analysis. The controversy raged until 1970, when the U.S. production of crude oil started to fall. Hubbert was right. Around 1995, several analysts began applying Hubbert's method to world oil production, and most of them estimate that the peak year for world oil will be between 2004 and 2008. These analyses were reported in some of the most widely circulated sources: Nature, Science, and Scientific American.2 None of our political leaders seem to be paying attention. If the predictions are correct, there will be enormous effects on the world economy. Even the poorest nations need fuel to run irrigation pumps. The industrialized nations will be bidding against one another for the dwindling oil supply. The good news is that we will put less carbon dioxide into the atmosphere. The bad news is that my pickup truck has a 25-gallon tank.

  13. Specific gas turbines for extreme peak-load

    International Nuclear Information System (INIS)

    Bellot, C.

    1992-12-01

    As with other European countries, in France peak consumption of electricity occurs during winter. Due to the increasing use of electricity for domestic heating, outside temperature greatly influences consumption (1 200 MW for a drop of 1 deg C). To meet requirements during cold spells, EDF has sought to determine which special facilities are best suited for extreme peak load conditions (i.e. offering short lifespan and minimum capital cost) and has studied the possibility of installing generation means in transformer substations (20 kV). This solution does not require extension of networks since these means are scattered near consumption areas. An experiment conducted on 3 Diesel generators of 800 kWe each at Senlis revealed some of the disadvantages of Diesel (maintenance requirements, polluting emissions and noise). EDF then examined, for this same application, the use of gas turbines, for which these drawbacks are significantly less. A study carried out under an EDF contract by the French manufacturer TURBOMECA showed that it is possible to design a small capacity gas turbine that can compete with Diesel generators, and that capital costs could be minimized by simplifying the machine, adapting its lifespan to extreme peak load needs, and taking advantage of lower cost provided by mass production. TURBOMECA defined the machine's characteristics (2 MW, 6 000 hours lifespan) and aerodynamic flow. It also estimated the cost of packaging. In terms of overall cost (including initial investment, maintenance and fuel) the gas turbine appears cheaper than Diesel generators for annual operation times of less than one hundred hours, which corresponds closely with extreme peak load use. The lower maintenance costs and the better availability counterbalance the higher capital cost (+6%) and the greater consumption (+50%). (author). 7 figs

  14. Hurricane Mitch: Peak Discharge for Selected River Reachesin Honduras

    Science.gov (United States)

    Smith, Mark E.; Phillips, Jeffrey V.; Spahr, Norman E.

    2002-01-01

    Hurricane Mitch began as a tropical depression in the Caribbean Sea on 22 October 1998. By 26 October, Mitch had strengthened to a Category 5 storm as defined by the Saffir-Simpson Hurricane Scale (National Climate Data Center, 1999a), and on 27 October was threatening the northern coast of Honduras (fig. 1). After making landfall 2 days later (29 October), the storm drifted south and west across Honduras, wreaking destruction throughout the country before reaching the Guatemalan border on 31 October. According to the National Climate Data Center of the National Oceanic and Atmospheric Administration (National Climate Data Center, 1999b), Hurricane Mitch ranks among the five strongest storms on record in the Atlantic Basin in terms of its sustained winds, barometric pressure, and duration. Hurricane Mitch also was one of the worst Atlantic storms in terms of loss of life and property. The regionwide death toll was estimated to be more than 9,000; thousands of people were reported missing. Economic losses in the region were more than $7.5 billion (U.S. Agency for International Development, 1999). Honduras suffered the most widespread devastation during the storm. More than 5,000 deaths, and economic losses of more than $4 billion, were reported by the Government of Honduras. Honduran officials estimated that Hurricane Mitch destroyed 50 years of economic development. In addition to the human and economic losses, intense flooding and landslides scarred the Honduran landscape - hydrologic and geomorphologic processes throughout the country likely will be affected for many years. As part of the U.S. Government's response to the disaster, the U.S. Geological Survey (USGS) conducted post-flood measurements of peak discharge at 16 river sites throughout Honduras (fig. 2). Such measurements, termed 'indirect' measurements, are used to determine peak flows when direct measurements (using current meters or dye studies, for example) cannot be made. Indirect measurements of

  15. Prediction of peak overlap in NMR spectra

    International Nuclear Information System (INIS)

    Hefke, Frederik; Schmucki, Roland; Güntert, Peter

    2013-01-01

    Peak overlap is one of the major factors complicating the analysis of biomolecular NMR spectra. We present a general method for predicting the extent of peak overlap in multidimensional NMR spectra and its validation using both, experimental data sets and Monte Carlo simulation. The method is based on knowledge of the magnetization transfer pathways of the NMR experiments and chemical shift statistics from the Biological Magnetic Resonance Data Bank. Assuming a normal distribution with characteristic mean value and standard deviation for the chemical shift of each observable atom, an analytic expression was derived for the expected overlap probability of the cross peaks. The analytical approach was verified to agree with the average peak overlap in a large number of individual peak lists simulated using the same chemical shift statistics. The method was applied to eight proteins, including an intrinsically disordered one, for which the prediction results could be compared with the actual overlap based on the experimentally measured chemical shifts. The extent of overlap predicted using only statistical chemical shift information was in good agreement with the overlap that was observed when the measured shifts were used in the virtual spectrum, except for the intrinsically disordered protein. Since the spectral complexity of a protein NMR spectrum is a crucial factor for protein structure determination, analytical overlap prediction can be used to identify potentially difficult proteins before conducting NMR experiments. Overlap predictions can be tailored to particular classes of proteins by preparing statistics from corresponding protein databases. The method is also suitable for optimizing recording parameters and labeling schemes for NMR experiments and improving the reliability of automated spectra analysis and protein structure determination.

  16. The peak in anomalous magnetic viscosity

    International Nuclear Information System (INIS)

    Collocott, S.J.; Watterson, P.A.; Tan, X.H.; Xu, H.

    2014-01-01

    Anomalous magnetic viscosity, where the magnetization as a function of time exhibits non-monotonic behaviour, being seen to increase, reach a peak, and then decrease, is observed on recoil lines in bulk amorphous ferromagnets, for certain magnetic prehistories. A simple geometrical approach based on the motion of the state line on the Preisach plane gives a theoretical framework for interpreting non-monotonic behaviour and explains the origin of the peak. This approach gives an expression for the time taken to reach the peak as a function of the applied (or holding) field. The theory is applied to experimental data for bulk amorphous ferromagnet alloys of composition Nd 60−x Fe 30 Al 10 Dy x , x = 0, 1, 2, 3 and 4, and it gives a reasonable description of the observed behaviour. The role played by other key magnetic parameters, such as the intrinsic coercivity and fluctuation field, is also discussed. When the non-monotonic behaviour of the magnetization of a number of alloys is viewed in the context of the model, features of universal behaviour emerge, that are independent of alloy composition. - Highlights: • Development of a simple geometrical model based on the Preisach model which gives a complete explanation of the peak in the magnetic viscosity. • Geometrical approach is extended by considering equations that govern the motion of the state line. • The model is used to deduce the relationship between the holding field and the time it takes to reach the peak. • The model is tested with experimental results for a range of Nd–Fe–Al–Dy bulk amorphous ferromagnets. • There is good agreement between the model and the experimental data

  17. The spatial resolution of epidemic peaks.

    Directory of Open Access Journals (Sweden)

    Harriet L Mills

    2014-04-01

    Full Text Available The emergence of novel respiratory pathogens can challenge the capacity of key health care resources, such as intensive care units, that are constrained to serve only specific geographical populations. An ability to predict the magnitude and timing of peak incidence at the scale of a single large population would help to accurately assess the value of interventions designed to reduce that peak. However, current disease-dynamic theory does not provide a clear understanding of the relationship between: epidemic trajectories at the scale of interest (e.g. city; population mobility; and higher resolution spatial effects (e.g. transmission within small neighbourhoods. Here, we used a spatially-explicit stochastic meta-population model of arbitrary spatial resolution to determine the effect of resolution on model-derived epidemic trajectories. We simulated an influenza-like pathogen spreading across theoretical and actual population densities and varied our assumptions about mobility using Latin-Hypercube sampling. Even though, by design, cumulative attack rates were the same for all resolutions and mobilities, peak incidences were different. Clear thresholds existed for all tested populations, such that models with resolutions lower than the threshold substantially overestimated population-wide peak incidence. The effect of resolution was most important in populations which were of lower density and lower mobility. With the expectation of accurate spatial incidence datasets in the near future, our objective was to provide a framework for how to use these data correctly in a spatial meta-population model. Our results suggest that there is a fundamental spatial resolution for any pathogen-population pair. If underlying interactions between pathogens and spatially heterogeneous populations are represented at this resolution or higher, accurate predictions of peak incidence for city-scale epidemics are feasible.

  18. Stereotactic Bragg peak proton radiosurgery method

    International Nuclear Information System (INIS)

    Kjellberg, R.N.

    1979-01-01

    A brief description of the technical aspects of a stereotactic Bragg peak proton radiosurgical method for the head is presented. The preparatory radiographic studies are outlined and the stereotactic instrument and positioning of the patient are described. The instrument is so calibrated that after corrections for soft tissue and bone thickness, the Bragg peak superimposes upon the intracranial target. The head is rotated at specific intervals to allow predetermined portals of access for the beam path, all of which converge on the intracranial target. Normally, portals are arranged to oppose and overlap from both sides of the head. Using a number of beams (in sequence) on both sides of the head, the target dose is far greater than the path dose. The procedure normally takes 3/2-2 hours, following which the patient can walk away. (Auth./C.F.)

  19. Central peaking of magnetized gas discharges

    International Nuclear Information System (INIS)

    Chen, Francis F.; Curreli, Davide

    2013-01-01

    Partially ionized gas discharges used in industry are often driven by radiofrequency (rf) power applied at the periphery of a cylinder. It is found that the plasma density n is usually flat or peaked on axis even if the skin depth of the rf field is thin compared with the chamber radius a. Previous attempts at explaining this did not account for the finite length of the discharge and the boundary conditions at the endplates. A simple 1D model is used to focus on the basic mechanism: the short-circuit effect. It is found that a strong electric field (E-field) scaled to electron temperature T e , drives the ions inward. The resulting density profile is peaked on axis and has a shape independent of pressure or discharge radius. This “universal” profile is not affected by a dc magnetic field (B-field) as long as the ion Larmor radius is larger than a

  20. Peak Oil, Food Systems, and Public Health

    Science.gov (United States)

    Parker, Cindy L.; Kirschenmann, Frederick L.; Tinch, Jennifer; Lawrence, Robert S.

    2011-01-01

    Peak oil is the phenomenon whereby global oil supplies will peak, then decline, with extraction growing increasingly costly. Today's globalized industrial food system depends on oil for fueling farm machinery, producing pesticides, and transporting goods. Biofuels production links oil prices to food prices. We examined food system vulnerability to rising oil prices and the public health consequences. In the short term, high food prices harm food security and equity. Over time, high prices will force the entire food system to adapt. Strong preparation and advance investment may mitigate the extent of dislocation and hunger. Certain social and policy changes could smooth adaptation; public health has an essential role in promoting a proactive, smart, and equitable transition that increases resilience and enables adequate food for all. PMID:21778492

  1. Hanford Site peak gust wind speeds

    International Nuclear Information System (INIS)

    Ramsdell, J.V.

    1998-01-01

    Peak gust wind data collected at the Hanford Site since 1945 are analyzed to estimate maximum wind speeds for use in structural design. The results are compared with design wind speeds proposed for the Hanford Site. These comparisons indicate that design wind speeds contained in a January 1998 advisory changing DOE-STD-1020-94 are excessive for the Hanford Site and that the design wind speeds in effect prior to the changes are still appropriate for the Hanford Site

  2. Commodity hydrogen from off-peak electricity

    Energy Technology Data Exchange (ETDEWEB)

    Darrow, K.; Biederman, N.; Konopka, A.

    1977-01-01

    This paper considers the use of off-peak electrical power as an energy source for the electrolytic production of hydrogen. The present industrial uses for hydrogen are examined to determine if hydrogen produced in this fashion would be competitive with the industry's onsite production or existing hydrogen prices. The paper presents a technical and economic feasibility analysis of the various components required and of the operation of the system as a whole including production, transmission, storage, and markets.

  3. Some practical aspects of peak kilovoltage measurements

    International Nuclear Information System (INIS)

    Irfan, A.Y.; Pugh, V.I.; Jeffery, C.D.

    1985-01-01

    The peak kilovoltage (kVsub(p)) across the X-ray tube electrodes in diagnostic X-ray machines is a most important parameter, affecting both radiation output and beam quality. Four commercially available non-invasive devices used for kVsub(p) measurement were tested using a selection of generator waveforms. The majority of the devices provided satisfactory measurements of the kVsub(p) to within approximately +- kV provided certain operating conditions are observed. (U.K.)

  4. METing SUSY on the Z peak

    Energy Technology Data Exchange (ETDEWEB)

    Barenboim, G.; Bernabeu, J.; Vives, O. [Universitat de Valencia, Departament de Fisica Teorica, Burjassot (Spain); Universitat de Valencia-CSIC, Parc Cientific U.V., IFIC, Paterna (Spain); Mitsou, V.A.; Romero, E. [Universitat de Valencia-CSIC, Parc Cientific U.V., IFIC, Paterna (Spain)

    2016-02-15

    Recently the ATLAS experiment announced a 3 σ excess at the Z-peak consisting of 29 pairs of leptons together with two or more jets, E{sub T}{sup miss} > 225 GeV and HT > 600 GeV, to be compared with 10.6 ± 3.2 expected lepton pairs in the Standard Model. No excess outside the Z-peak was observed. By trying to explain this signal with SUSY we find that only relatively light gluinos, m{sub g} or similar 400 GeV decaying predominantly to Z-boson plus a light gravitino, such that nearly every gluino produces at least one Z-boson in its decay chain, could reproduce the excess. We construct an explicit general gauge mediation model able to reproduce the observed signal overcoming all the experimental limits. Needless to say, more sophisticated models could also reproduce the signal, however, any model would have to exhibit the following features: light gluinos, or heavy particles with a strong production cross section, producing at least one Z-boson in its decay chain. The implications of our findings for the Run II at LHC with the scaling on the Z peak, as well as for the direct search of gluinos and other SUSY particles, are pointed out. (orig.)

  5. Acquisition of peak responding: what is learned?

    Science.gov (United States)

    Balci, Fuat; Gallistel, Charles R; Allen, Brian D; Frank, Krystal M; Gibson, Jacqueline M; Brunner, Daniela

    2009-01-01

    We investigated how the common measures of timing performance behaved in the course of training on the peak procedure in C3H mice. Following fixed interval (FI) pre-training, mice received 16 days of training in the peak procedure. The peak time and spread were derived from the average response rates while the start and stop times and their relative variability were derived from a single-trial analysis. Temporal precision (response spread) appeared to improve in the course of training. This apparent improvement in precision was, however, an averaging artifact; it was mediated by the staggered appearance of timed stops, rather than by the delayed occurrence of start times. Trial-by-trial analysis of the stop times for individual subjects revealed that stops appeared abruptly after three to five sessions and their timing did not change as training was prolonged. Start times and the precision of start and stop times were generally stable throughout training. Our results show that subjects do not gradually learn to time their start or stop of responding. Instead, they learn the duration of the FI, with robust temporal control over the start of the response; the control over the stop of response appears abruptly later.

  6. METing SUSY on the Z peak

    International Nuclear Information System (INIS)

    Barenboim, G.; Bernabeu, J.; Vives, O.; Mitsou, V.A.; Romero, E.

    2016-01-01

    Recently the ATLAS experiment announced a 3 σ excess at the Z-peak consisting of 29 pairs of leptons together with two or more jets, E T miss > 225 GeV and HT > 600 GeV, to be compared with 10.6 ± 3.2 expected lepton pairs in the Standard Model. No excess outside the Z-peak was observed. By trying to explain this signal with SUSY we find that only relatively light gluinos, m g or similar 400 GeV decaying predominantly to Z-boson plus a light gravitino, such that nearly every gluino produces at least one Z-boson in its decay chain, could reproduce the excess. We construct an explicit general gauge mediation model able to reproduce the observed signal overcoming all the experimental limits. Needless to say, more sophisticated models could also reproduce the signal, however, any model would have to exhibit the following features: light gluinos, or heavy particles with a strong production cross section, producing at least one Z-boson in its decay chain. The implications of our findings for the Run II at LHC with the scaling on the Z peak, as well as for the direct search of gluinos and other SUSY particles, are pointed out. (orig.)

  7. Monitoring device for local power peaking coefficients

    International Nuclear Information System (INIS)

    Mihashi, Ishi

    1987-01-01

    Purpose: To determine and monitor the local power peaking coefficients by a method not depending on the combination of fuel types. Constitution: Representative values for the local power distribution can be obtained by determining corresponding burn-up degrees based on the burn-up degree of each of fuel assembly segments obtained in a power distribution monitor and by the interpolation and extrapolation of void coefficients. The typical values are multiplied with compensation coefficients for the control rod effect and coefficients for compensating the effect of adjacent fuel assemblies in a calculation device to obtain typical values for the present local power distribution compensated with all of the effects. Further, the calculation device compares them with typical values of the present local power distribution to obtain an aimed local power peaking coefficient as the maximum value thereof. According to the present invention, since the local power peaking coefficients can be determined not depending on the combination of the kind of fuels, if the combination of fuel assemblies is increased upon fuel change, the amount of operation therefor is not increased. (Kamimura, M.)

  8. Chinese emissions peak: Not when, but how

    International Nuclear Information System (INIS)

    Spencer, Thomas; Colombier, Michel; Wang, Xin; Sartor, Oliver; Waisman, Henri

    2016-07-01

    It seems highly likely that China will overachieve its 2020 and 2030 targets, and peak its emissions before 2030 and possibly at a lower level than often assumed. This paper argues that the debate on the timing of the peak is misplaced: what matters is not when by why. For the peak to be seen as a harbinger of deep transformation, it needs to be based on significant macro-economic reform and restructuring, with attendant improvement in energy intensity. The Chinese economic model has been extraordinarily investment and resource intensive, and has driven the growth in GHG emissions. That model is no longer economically or environmentally sustainable. Therefore Chinese policy-makers are faced with a trade-off between slower short-term growth and economic reform, versus supporting short-term growth but slowing economic reform. The outcome will be crucial for the transition to a low-carbon economy. Overall, the 13. FYP (2016-2020) gives the impression of a cautious reflection of the new normal paradigm on the economic front, and a somewhat conservative translation of this shift into the energy and climate targets. Nonetheless, the 13. FYP targets set China well on the way to overachieving its 2020 pledge undertaken at COP15 in Copenhagen, and to potentially overachieving its INDC. It thus seems likely that China will achieve its emissions peak before 2030. However, the crucial question is not when China peaks, but whether the underlying transformation of the Chinese economy and energy system lays the basis for deep decarbonization thereafter. Thorough assessments of the implications of the 'new normal' for Chinese emissions and energy system trajectories, taking into account the link with the Chinese macro-economy, are needed. Scenarios provide a useful framework and should focus on a number of short-term uncertainties. Most energy system and emissions scenarios published today assume a continuity of trends between 2010-2015 and 2015-2020, which is at odds with clear

  9. Particle creation by peak electric field

    Energy Technology Data Exchange (ETDEWEB)

    Adorno, T.C. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); Gavrilov, S.P. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); Herzen State Pedagogical University of Russia, Department of General and Experimental Physics, St. Petersburg (Russian Federation); Gitman, D.M. [Tomsk State University, Department of Physics, Tomsk (Russian Federation); P. N. Lebedev Physical Institute, Moscow (Russian Federation); University of Sao Paulo, Institute of Physics, CP 66318, Sao Paulo, SP (Brazil)

    2016-08-15

    The particle creation by the so-called peak electric field is considered. The latter field is a combination of two exponential parts, one exponentially increasing and another exponentially decreasing. We find exact solutions of the Dirac equation with the field under consideration with appropriate asymptotic conditions and calculate all the characteristics of particle creation effect, in particular, differential mean numbers of created particle, total number of created particles, and the probability for a vacuum to remain a vacuum. Characteristic asymptotic regimes are discussed in detail and a comparison with the pure asymptotically decaying field is considered. (orig.)

  10. Octant vectorcardiography - the evaluation by peaks.

    Science.gov (United States)

    Laufberger, V

    1982-01-01

    From the Frank lead potentials a computer prints out an elementary table. Therein, the electrical space of left ventricle depolarization is divided into eight spatial parts labelled by numbers 1-8 and called octants. Within these octants six peaks are determined labelled with letters ALPR-IS. Their localization is described by six-digit topograms characteristic for each patient. From 300 cases of patients after myocardial infarction, three data bases were compiled enabling every case to be classified into classes, subclasses and types. The follow up of patients according to these principles gives an objective and detailed image about the progress of coronary artery disease.

  11. Energy peaks: A high energy physics outlook

    Science.gov (United States)

    Franceschini, Roberto

    2017-12-01

    Energy distributions of decay products carry information on the kinematics of the decay in ways that are at the same time straightforward and quite hidden. I will review these properties and discuss their early historical applications, as well as more recent ones in the context of (i) methods for the measurement of masses of new physics particle with semi-invisible decays, (ii) the characterization of Dark Matter particles produced at colliders, (iii) precision mass measurements of Standard Model particles, in particular of the top quark. Finally, I will give an outlook of further developments and applications of energy peak method for high energy physics at colliders and beyond.

  12. Steam generator deposit control program assessment at Comanche Peak

    International Nuclear Information System (INIS)

    Stevens, J.; Fellers, B.; Orbon, S.

    2002-01-01

    Comanche Peak has employed a variety of methods to assess the effectiveness of the deposit control program. These include typical methods such as an extensive visual inspection program and detailed corrosion product analysis and trending. In addition, a recently pioneered technique, low frequency eddy current profile analysis (LFEC) has been utilized. LFEC provides a visual mapping of the magnetite deposit profile of the steam generator. Analysis of the LFEC results not only provides general area deposition rates, but can also provide local deposition patterns, which is indicative of steam generator performance. Other techniques utilized include trending of steam pressure, steam generator hideout-return, and flow assisted corrosion (FAC) results. The sum of this information provides a comprehensive assessment of the deposit control program effectiveness and the condition of the steam generator. It also provides important diagnostic and predictive information relative to steam generator life management and mitigative strategies, such as special cleaning procedures. This paper discusses the techniques employed by Comanche Peak Chemistry to monitor the effectiveness of the deposit control program and describes how this information is used in strategic planning. (authors)

  13. Method and apparatus for current-output peak detection

    Science.gov (United States)

    De Geronimo, Gianluigi

    2017-01-24

    A method and apparatus for a current-output peak detector. A current-output peak detector circuit is disclosed and works in two phases. The peak detector circuit includes switches to switch the peak detector circuit from the first phase to the second phase upon detection of the peak voltage of an input voltage signal. The peak detector generates a current output with a high degree of accuracy in the second phase.

  14. Monitoring device for local power peaking coefficient

    International Nuclear Information System (INIS)

    Mitsuhashi, Ishi

    1987-01-01

    Purpose: To monitor the local power peaking coefficients obtained by the method not depending on the combination of fuel types. Method: A plurality of representative values for the local power distribution determined by the nuclear constant calculation for one fuel assembly are memorized regarding each of the burn-up degree and the void coefficient on every positions and fuel types in fuel rod assemblies. While on the other hand, the representative values for the local power distribution as described above are compensated by a compensation coefficient considering the effect of adjacent segments and a control rod compensation coefficient considering the effect due to the control rod insertion relative to the just-mentioned compensation coefficient. Then, the maximum value among them is selected to determine the local power peaking coefficient at each of the times and each of the segments, which is monitored. According to this system, the calculation and the working required for the fitting work depending on the combination of fuel types are no more required at all to facilitate the maintenance as well. (Horiuchi, T.)

  15. Petrographic Analysis and Geochemical Source Correlation of Pigeon Peak, Sutter Buttes, CA

    Science.gov (United States)

    Novotny, N. M.; Hausback, B. P.

    2013-12-01

    The Sutter Buttes are a volcanic complex located in the center of the Great Valley north of Sacramento. They are comprised of numerous inter-intruding andesite and rhyolite lava domes of varying compositions surrounded by a shallow rampart of associated tephras. The Pigeon Peak block-and-ash flow sequence is located in the rampart and made up of a porphyritic Biotite bearing Hornblende Andesite. The andesite blocks demonstrate a high degree of propylization in hornblende crystals, highly zoned plagioclase, trace olivine, and display a red to gray color gradation. DAR is an andesite dome located less than one mile from Pigeon Peak. Of the 15 to 25 andesite lava domes within four miles from Pigeon Peak, only DAR displays trace olivine, red to grey color stratification, low biotite content, and propylitized hornblende. These characteristic similarities suggest that DAR may be the source for Pigeon Peak. My investigation used microprobe analysis of the DAR and Pigeon Peak feldspar crystals to identify the magmatic history of the magma body before emplacement. Correlation of the anorthite zoning within the feldspars from both locations support my hypothesis that DAR is the source of the Pigeon Peak block-and-ash flow.

  16. Peak Wind Tool for General Forecasting

    Science.gov (United States)

    Barrett, Joe H., III

    2010-01-01

    The expected peak wind speed of the day is an important forecast element in the 45th Weather Squadron's (45 WS) daily 24-Hour and Weekly Planning Forecasts. The forecasts are used for ground and space launch operations at the Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS). The 45 WS also issues wind advisories for KSC/CCAFS when they expect wind gusts to meet or exceed 25 kt, 35 kt and 50 kt thresholds at any level from the surface to 300 ft. The 45 WS forecasters have indicated peak wind speeds are challenging to forecast, particularly in the cool season months of October - April. In Phase I of this task, the Applied Meteorology Unit (AMU) developed a tool to help the 45 WS forecast non-convective winds at KSC/CCAFS for the 24-hour period of 0800 to 0800 local time. The tool was delivered as a Microsoft Excel graphical user interface (GUI). The GUI displayed the forecast of peak wind speed, 5-minute average wind speed at the time of the peak wind, timing of the peak wind and probability the peak speed would meet or exceed 25 kt, 35 kt and 50 kt. For the current task (Phase II ), the 45 WS requested additional observations be used for the creation of the forecast equations by expanding the period of record (POR). Additional parameters were evaluated as predictors, including wind speeds between 500 ft and 3000 ft, static stability classification, Bulk Richardson Number, mixing depth, vertical wind shear, temperature inversion strength and depth and wind direction. Using a verification data set, the AMU compared the performance of the Phase I and II prediction methods. Just as in Phase I, the tool was delivered as a Microsoft Excel GUI. The 45 WS requested the tool also be available in the Meteorological Interactive Data Display System (MIDDS). The AMU first expanded the POR by two years by adding tower observations, surface observations and CCAFS (XMR) soundings for the cool season months of March 2007 to April 2009. The POR was expanded

  17. Emissions Scenarios and Fossil-fuel Peaking

    Science.gov (United States)

    Brecha, R.

    2008-12-01

    Intergovernmental Panel on Climate Change (IPCC) emissions scenarios are based on detailed energy system models in which demographics, technology and economics are used to generate projections of future world energy consumption, and therefore, of greenhouse gas emissions. Built into the assumptions for these scenarios are estimates for ultimately recoverable resources of various fossil fuels. There is a growing chorus of critics who believe that the true extent of recoverable fossil resources is much smaller than the amounts taken as a baseline for the IPCC scenarios. In a climate optimist camp are those who contend that "peak oil" will lead to a switch to renewable energy sources, while others point out that high prices for oil caused by supply limitations could very well lead to a transition to liquid fuels that actually increase total carbon emissions. We examine a third scenario in which high energy prices, which are correlated with increasing infrastructure, exploration and development costs, conspire to limit the potential for making a switch to coal or natural gas for liquid fuels. In addition, the same increasing costs limit the potential for expansion of tar sand and shale oil recovery. In our qualitative model of the energy system, backed by data from short- and medium-term trends, we have a useful way to gain a sense of potential carbon emission bounds. A bound for 21st century emissions is investigated based on two assumptions: first, that extractable fossil-fuel resources follow the trends assumed by "peak oil" adherents, and second, that little is done in the way of climate mitigation policies. If resources, and perhaps more importantly, extraction rates, of fossil fuels are limited compared to assumptions in the emissions scenarios, a situation can arise in which emissions are supply-driven. However, we show that even in this "peak fossil-fuel" limit, carbon emissions are high enough to surpass 550 ppm or 2°C climate protection guardrails. Some

  18. Peak Electric Load Relief in Northern Manhattan

    Directory of Open Access Journals (Sweden)

    Hildegaard D. Link

    2014-08-01

    Full Text Available The aphorism “Think globally, act locally,” attributed to René Dubos, reflects the vision that the solution to global environmental problems must begin with efforts within our communities. PlaNYC 2030, the New York City sustainability plan, is the starting point for this study. Results include (a a case study based on the City College of New York (CCNY energy audit, in which we model the impacts of green roofs on campus energy demand and (b a case study of energy use at the neighborhood scale. We find that reducing the urban heat island effect can reduce building cooling requirements, peak electricity loads stress on the local electricity grid and improve urban livability.

  19. Tim Peake and Britain's road to space

    CERN Document Server

    Seedhouse, Erik

    2017-01-01

    This book puts the reader in the flight suit of Britain’s first male astronaut, Tim Peake. It chronicles his life, along with the Principia mission and the down-to-the-last-bolt descriptions of life aboard the ISS, by way of the hurdles placed by the British government and the rigors of training at Russia’s Star City military base. In addition, this book discusses the learning curves required in astronaut and mission training and the complexity of the technologies required to launch an astronaut and keep them alive for months on end. This book underscores the fact that technology and training, unlike space, do not exist in a vacuum; complex technical systems, like the ISS, interact with the variables of human personality, and the cultural background of the astronauts. .

  20. Complex behavior of elevators in peak traffic

    Science.gov (United States)

    Nagatani, Takashi

    2003-08-01

    We study the dynamical behavior of elevators in the morning peak traffic. We present a stochastic model of the elevators to take into account the interactions between elevators through passengers. The dynamics of the elevators is expressed in terms of a coupled nonlinear map with noises. The number of passengers carried by an elevator and the time-headway between elevators exhibit the complex behavior with varying elevator trips. It is found that the behavior of elevators exhibits a deterministic chaos even if there are no noises. The chaotic motion depends on the loading parameter, the maximum capacity of an elevator, and the number of elevators. When the loading parameter is superior to the threshold, each elevator carries a full load of passengers throughout its trip. The dependence of the threshold (transition point) on the elevator capacity is clarified.

  1. Equivalence principle and the baryon acoustic peak

    Science.gov (United States)

    Baldauf, Tobias; Mirbabayi, Mehrdad; Simonović, Marko; Zaldarriaga, Matias

    2015-08-01

    We study the dominant effect of a long wavelength density perturbation δ (λL) on short distance physics. In the nonrelativistic limit, the result is a uniform acceleration, fixed by the equivalence principle, and typically has no effect on statistical averages due to translational invariance. This same reasoning has been formalized to obtain a "consistency condition" on the cosmological correlation functions. In the presence of a feature, such as the acoustic peak at ℓBAO, this naive expectation breaks down for λLexplicitly applied to the one-loop calculation of the power spectrum. Finally, the success of baryon acoustic oscillation reconstruction schemes is argued to be another empirical evidence for the validity of the results.

  2. Modelling of peak temperature during friction stir processing of magnesium alloy AZ91

    Science.gov (United States)

    Vaira Vignesh, R.; Padmanaban, R.

    2018-02-01

    Friction stir processing (FSP) is a solid state processing technique with potential to modify the properties of the material through microstructural modification. The study of heat transfer in FSP aids in the identification of defects like flash, inadequate heat input, poor material flow and mixing etc. In this paper, transient temperature distribution during FSP of magnesium alloy AZ91 was simulated using finite element modelling. The numerical model results were validated using the experimental results from the published literature. The model was used to predict the peak temperature obtained during FSP for various process parameter combinations. The simulated peak temperature results were used to develop a statistical model. The effect of process parameters namely tool rotation speed, tool traverse speed and shoulder diameter of the tool on the peak temperature was investigated using the developed statistical model. It was found that peak temperature was directly proportional to tool rotation speed and shoulder diameter and inversely proportional to tool traverse speed.

  3. Impact on the aquatic environment of hydro-peaking in hydroelectric plants

    International Nuclear Information System (INIS)

    Sabaton, C.; Lauters, F.; Valentin, S.

    1996-01-01

    There are a number of types of hydroelectric installations on French rivers. Some of these intermittently turbine water stored in dammed reservoirs, in order to use available reserves at the most opportune moment for power generation. These plants, run under 'hydro-peaking' management procedures, cause variations in discharge in river sections downstream of the restitution, on a daily or weekly scale. To answer questions concerning the impact of such variations in discharge on the aquatic environment, EDF launched a research program aimed at describing and better understanding the physical and biological phenomena related to hydro-peaking and assessing the possible impact of this type of plant management on French streams. Seven sites subjects to hydro-peaking were studied on rivers with mean flow rates lower than 20 m 3 /s (which corresponds to over 65 % of EDF hydro-peaking sites). Four themes in particular were examined: hydraulic characterization of hydro-peaking, modifications in thermal regime and water quality, response of benthic invertebrates and response of fish populations to hydro-peaking. For fish as well as for invertebrates, the role of the base discharge - in the absence of peaking flow - and that of the morphology of the river bed (and, in particular, the presence of shelter for fish) during periods of strong discharge were clearly highlighted. Impact assessment requires a precise diagnosis of the state of biocenoses. To carry out such a diagnosis, one must reason in terms of species, life phase (particularly the most sensitive phases) and population structure as well as the type of stream and the faunizone involved. A risk assessment is possible by means of simultaneous study of the morphology of the river bed and the response of the signal generated by hydro-peaking in terms of hydrology and physical characteristics downstream of the restitution. (authors)

  4. A Framework for Understanding and Generating Integrated Solutions for Residential Peak Energy Demand

    Science.gov (United States)

    Buys, Laurie; Vine, Desley; Ledwich, Gerard; Bell, John; Mengersen, Kerrie; Morris, Peter; Lewis, Jim

    2015-01-01

    Supplying peak energy demand in a cost effective, reliable manner is a critical focus for utilities internationally. Successfully addressing peak energy concerns requires understanding of all the factors that affect electricity demand especially at peak times. This paper is based on past attempts of proposing models designed to aid our understanding of the influences on residential peak energy demand in a systematic and comprehensive way. Our model has been developed through a group model building process as a systems framework of the problem situation to model the complexity within and between systems and indicate how changes in one element might flow on to others. It is comprised of themes (social, technical and change management options) networked together in a way that captures their influence and association with each other and also their influence, association and impact on appliance usage and residential peak energy demand. The real value of the model is in creating awareness, understanding and insight into the complexity of residential peak energy demand and in working with this complexity to identify and integrate the social, technical and change management option themes and their impact on appliance usage and residential energy demand at peak times. PMID:25807384

  5. Norwegian hydropower a valuable peak power source

    Energy Technology Data Exchange (ETDEWEB)

    Brekke, Hermod

    2010-07-01

    given on a possible increase of the Norwegian hydropower peak power production to meet the growing the European demand for peak power caused by the growing non stationary production from wind mills and ocean energy from waves and sea current. Also building of reversible pump turbine power plants will be discussed even if approximately 10% power will be consumed by loss in the pumping phase compared to direct use of the water from reservoirs. (Author)

  6. Can You Hear That Peak? Utilization of Auditory and Visual Feedback at Peak Limb Velocity

    Science.gov (United States)

    Loria, Tristan; de Grosbois, John; Tremblay, Luc

    2016-01-01

    Purpose: At rest, the central nervous system combines and integrates multisensory cues to yield an optimal percept. When engaging in action, the relative weighing of sensory modalities has been shown to be altered. Because the timing of peak velocity is the critical moment in some goal-directed movements (e.g., overarm throwing), the current study…

  7. OccuPeak: ChIP-Seq peak calling based on internal background modelling

    NARCIS (Netherlands)

    de Boer, Bouke A.; van Duijvenboden, Karel; van den Boogaard, Malou; Christoffels, Vincent M.; Barnett, Phil; Ruijter, Jan M.

    2014-01-01

    ChIP-seq has become a major tool for the genome-wide identification of transcription factor binding or histone modification sites. Most peak-calling algorithms require input control datasets to model the occurrence of background reads to account for local sequencing and GC bias. However, the

  8. Prediction of iodine activity peak during refuelling

    International Nuclear Information System (INIS)

    Hozer, Z.; Vajda, N.

    2001-01-01

    The increase of fission product activities in the primary circuit of a nuclear power plant indicates the existence of defects in some fuel rods. The power change leads to the cooling down of the fuel and results in the fragmentation of the UO 2 pellets, which facilitates the release of fission products from the intergranular regions. Furthermore the injection of boric acid after shutdown will increase the primary activity, due to the solution of deposited fission products from the surface of the core components. The calculation of these phenomena usually is based on the evaluation of activity measurements and power plant data. The estimation of iodine spiking peak during reactor transients is based on correlation with operating parameters, such as reactor power and primary pressure. The approach used in the present method was applied for CANDU reactors. The VVER-440 specific correlations were determined using the activity measurements of the Paks NPP and the data provided by the Russian fuel supplier. The present method is used for the evaluation of the iodine isotopes, as well as the noble gases. A numerical model has been developed for iodine spiking simulation and has been validated against several shutdown transients, measured at Paks NPP. (R.P.)

  9. Fast clustering using adaptive density peak detection.

    Science.gov (United States)

    Wang, Xiao-Feng; Xu, Yifan

    2017-12-01

    Common limitations of clustering methods include the slow algorithm convergence, the instability of the pre-specification on a number of intrinsic parameters, and the lack of robustness to outliers. A recent clustering approach proposed a fast search algorithm of cluster centers based on their local densities. However, the selection of the key intrinsic parameters in the algorithm was not systematically investigated. It is relatively difficult to estimate the "optimal" parameters since the original definition of the local density in the algorithm is based on a truncated counting measure. In this paper, we propose a clustering procedure with adaptive density peak detection, where the local density is estimated through the nonparametric multivariate kernel estimation. The model parameter is then able to be calculated from the equations with statistical theoretical justification. We also develop an automatic cluster centroid selection method through maximizing an average silhouette index. The advantage and flexibility of the proposed method are demonstrated through simulation studies and the analysis of a few benchmark gene expression data sets. The method only needs to perform in one single step without any iteration and thus is fast and has a great potential to apply on big data analysis. A user-friendly R package ADPclust is developed for public use.

  10. Modeling the peak of emergence in systems: Design and katachi.

    Science.gov (United States)

    Cardier, Beth; Goranson, H T; Casas, Niccolo; Lundberg, Patric; Erioli, Alessio; Takaki, Ryuji; Nagy, Dénes; Ciavarra, Richard; Sanford, Larry D

    2017-12-01

    It is difficult to model emergence in biological systems using reductionist paradigms. A requirement for computational modeling is that individual entities can be recorded parametrically and related logically, but their transformation into whole systems cannot be captured this way. The problem stems from an inability to formally represent the implicit influences that inform emergent organization, such as context, shifts in causal agency or scale, and self-reference. This lack hampers biological systems modeling and its computational counterpart, indicating a need for new fundamental abstraction frameworks that support system-level characteristics. We develop an approach that formally captures these characteristics, focusing on the way they come together to enable transformation at the 'peak' of the emergent process. An example from virology is presented, in which two seemingly antagonistic systems - the herpes cold sore virus and its host - are capable of altering their basic biological objectives to achieve a new equilibrium. The usual barriers to modeling this process are overcome by incorporating mechanisms from practices centered on its emergent peak: design and katachi. In the Japanese science of form, katachi refers to the emergence of intrinsic structure from real situations, where an optimal balance between implicit influences is achieved. Design indicates how such optimization is guided by principles of flow. These practices leverage qualities of situated abstraction, which we understand through the intuitive method of physicist Kôdi Husimi. Early results indicate that this approach can capture the functional transformations of biological emergence, whilst being reasonably computable. Due to its geometric foundations and narrative-based extension to logic, the method will also generate speculative predictions. This research forms the foundations of a new biomedical modeling platform, which is discussed. Copyright © 2017. Published by Elsevier Ltd.

  11. ST peak during percutaneous coronary intervention serves as an early prognostic predictor in patients with ST-segment elevation myocardial

    DEFF Research Database (Denmark)

    Lønborg, Jacob; Kelbæk, Henning; Engstrøm, Thomas

    2014-01-01

    AIMS: To evaluate the clinical importance of the ST peak phenomenon during primary percutaneous coronary intervention (PCI) in patients with ST-segment elevation myocardial infarction (STEMI). METHODS AND RESULTS: Continuous ST monitoring was performed in 942 STEMI patients from arrival until 90...... minutes after revascularisation. ST peak was defined as ≥1 mm increase in the ST-segment during PCI compared with the ST elevation before intervention. ST peak was observed in 26.9% of patients. During median follow-up of 4.1 years, 20.7% of patients experienced a major adverse cardiac event (MACE). ST...... and ST peak including ST resolution and epicardial flow, ST peak remained significantly associated with MACE: adjusted hazard ratio (HR) 1.40 (95% confidence interval [CI] 1.01-1.95) and 1.41 (95% CI: 1.02-1.96). CONCLUSIONS: In the largest study hitherto evaluating the ST peak phenomenon during primary...

  12. Research Opportunities at Storm Peak Laboratory

    Science.gov (United States)

    Hallar, A. G.; McCubbin, I. B.

    2006-12-01

    The Desert Research Institute (DRI) operates a high elevation facility, Storm Peak Laboratory (SPL), located on the west summit of Mt. Werner in the Park Range near Steamboat Springs, Colorado at an elevation of 3210 m MSL (Borys and Wetzel, 1997). SPL provides an ideal location for long-term research on the interactions of atmospheric aerosol and gas- phase chemistry with cloud and natural radiation environments. The ridge-top location produces almost daily transition from free tropospheric to boundary layer air which occurs near midday in both summer and winter seasons. Long-term observations at SPL document the role of orographically induced mixing and convection on vertical pollutant transport and dispersion. During winter, SPL is above cloud base 25% of the time, providing a unique capability for studying aerosol-cloud interactions (Borys and Wetzel, 1997). A comprehensive set of continuous aerosol measurements was initiated at SPL in 2002. SPL includes an office-type laboratory room for computer and instrumentation setup with outside air ports and cable access to the roof deck, a cold room for precipitation and cloud rime ice sample handling and ice crystal microphotography, a 150 m2 roof deck area for outside sampling equipment, a full kitchen and two bunk rooms with sleeping space for nine persons. The laboratory is currently well equipped for aerosol and cloud measurements. Particles are sampled from an insulated, 15 cm diameter manifold within approximately 1 m of its horizontal entry point through an outside wall. The 4 m high vertical section outside the building is capped with an inverted can to exclude large particles.

  13. Peak MSC—Are We There Yet?

    Directory of Open Access Journals (Sweden)

    Timothy R. Olsen

    2018-06-01

    Full Text Available Human mesenchymal stem cells (hMSCs are a critical raw material for many regenerative medicine products, including cell-based therapies, engineered tissues, or combination products, and are on the brink of radically changing how the world of medicine operates. Their unique characteristics, potential to treat many indications, and established safety profile in more than 800 clinical trials have contributed to their current consumption and will only fuel future demand. Given the large target patient populations with typical dose sizes of 10's to 100's of millions of cells per patient, and engineered tissues being constructed with 100's of millions to billions of cells, an unprecedented demand has been created for hMSCs. The fulfillment of this demand faces an uphill challenge in the limited availability of large quantities of pharmaceutical grade hMSCs for the industry—fueling the need for parallel rapid advancements in the biomanufacturing of this living critical raw material. Simply put, hMSCs are no different than technologies like transistors, as they are a highly technical and modular product that requires stringent control over manufacturing that can allow for high quality and consistent performance. As hMSC manufacturing processes are optimized, it predicts a future time of abundance for hMSCs, where scientists and researchers around the world will have access to a consistent and readily available supply of high quality, standardized, and economical pharmaceutical grade product to buy off the shelf for their applications and drive product development—this is “Peak MSC.”

  14. Peak-valley-peak pattern of histone modifications delineates active regulatory elements and their directionality

    DEFF Research Database (Denmark)

    Pundhir, Sachin; Bagger, Frederik Otzen; Lauridsen, Felicia Kathrine Bratt

    2016-01-01

    Formation of nucleosome free region (NFR) accompanied by specific histone modifications at flanking nucleosomes is an important prerequisite for enhancer and promoter activity. Due to this process, active regulatory elements often exhibit a distinct shape of histone signal in the form of a peak......-valley-peak (PVP) pattern. However, different features of PVP patterns and their robustness in predicting active regulatory elements have never been systematically analyzed. Here, we present PARE, a novel computational method that systematically analyzes the H3K4me1 or H3K4me3 PVP patterns to predict NFRs. We show...... four ENCODE cell lines and four hematopoietic differentiation stages, we identified several enhancers whose regulatory activity is stage specific and correlates positively with the expression of proximal genes in a particular stage. In conclusion, our results demonstrate that PVP patterns delineate...

  15. Modified echo peak correction for radial acquisition regime (RADAR).

    Science.gov (United States)

    Takizawa, Masahiro; Ito, Taeko; Itagaki, Hiroyuki; Takahashi, Tetsuhiko; Shimizu, Kanichirou; Harada, Junta

    2009-01-01

    Because radial sampling imposes many limitations on magnetic resonance (MR) imaging hardware, such as on the accuracy of the gradient magnetic field or the homogeneity of B(0), some correction of the echo signal is usually needed before image reconstruction. In our previous study, we developed an echo-peak-shift correction (EPSC) algorithm not easily affected by hardware performance. However, some artifacts remained in lung imaging, where tissue is almost absent, or in cardiac imaging, which is affected by blood flow. In this study, we modified the EPSC algorithm to improve the image quality of the radial aquisition regime (RADAR) and expand its application sequences. We assumed the artifacts were mainly caused by errors in the phase map for EPSC and used a phantom on a 1.5-tesla (T) MR scanner to investigate whether to modify the EPSC algorithm. To evaluate the effectiveness of EPSC, we compared results from T(1)- and T(2)-weighted images of a volunteer's lung region using the current and modified EPSC. We then applied the modified EPSC to RADAR spin echo (SE) and RADAR balanced steady-state acquisition with rewound gradient echo (BASG) sequence. The modified EPSC reduced phase discontinuity in the reference data used for EPSC and improved visualization of blood vessels in the lungs. Motion and blood flow caused no visible artifacts in the resulting images in either RADAR SE or RADAR BASG sequence. Use of the modified EPSC eliminated artifacts caused by signal loss in the reference data for EPSC. In addition, the modified EPSC was applied to RADAR SE and RADAR BASG sequences.

  16. Modified echo peak correction for radial acquisition regime (RADAR)

    International Nuclear Information System (INIS)

    Takizawa, Masahiro; Ito, Taeko; Itagaki, Hiroyuki; Takahashi, Tetsuhiko; Shimizu, Kanichirou; Harada, Junta

    2009-01-01

    Because radial sampling imposes many limitations on magnetic resonance (MR) imaging hardware, such as on the accuracy of the gradient magnetic field or the homogeneity of B 0 , some correction of the echo signal is usually needed before image reconstruction. In our previous study, we developed an echo-peak-shift correction (EPSC) algorithm not easily affected by hardware performance. However, some artifacts remained in lung imaging, where tissue is almost absent, or in cardiac imaging, which is affected by blood flow. In this study, we modified the EPSC algorithm to improve the image quality of the radial acquisition regime (RADAR) and expand its application sequences. We assumed the artifacts were mainly caused by errors in the phase map for EPSC and used a phantom on a 1.5-tesla (T) MR scanner to investigate whether to modify the EPSC algorithm. To evaluate the effectiveness of EPSC, we compared results from T 1 -and T 2 -weighted images of a volunteer's lung region using the current and modified EPSC. We then applied the modified EPSC to RADAR spin echo (SE) and RADAR balanced steady-state acquisition with rewound gradient echo (BASG) sequence. The modified EPSC reduced phase discontinuity in the reference data used for EPSC and improved visualization of blood vessels in the lungs. Motion and blood flow caused no visible artifacts in the resulting images in either RADAR SE or RADAR BASG sequence. Use of the modified EPSC eliminated artifacts caused by signal loss in the reference data for EPSC. In addition, the modified EPSC was applied to RADAR SE and RADAR BASG sequences. (author)

  17. Peak Oil profiles through the lens of a general equilibrium assessment

    International Nuclear Information System (INIS)

    Waisman, Henri; Rozenberg, Julie; Sassi, Olivier; Hourcade, Jean-Charles

    2012-01-01

    This paper disentangles the interactions between oil production profiles, the dynamics of oil prices and growth trends. We do so through a general equilibrium model in which Peak Oil endogenously emerges from the interplay between the geological, technical, macroeconomic and geopolitical determinants of supply and demand under non-perfect expectations. We analyze the macroeconomic effects of oil production profiles and demonstrate that Peak Oil dates that differ only slightly may lead to very different time profiles of oil prices, exportation flows and economic activity. We investigate Middle-East's trade-off between different pricing trajectories in function of two alternative objectives (maximisation of oil revenues or households’ welfare) and assess its impact on OECD growth trajectories. A sensitivity analysis highlights the respective roles of the amount of resources, inertia on the deployment of non conventional oil and short-term oil price dynamics on Peak Oil dates and long-term oil prices. It also examines the effects of these assumptions on OECD growth and Middle-East strategic tradeoffs. - Highlights: ► Geological determinants behind Hubbert curves in a general equilibrium framework. ► We endogenize the interactions between Peak Oil dates, oil prices and growth trends. ► Close Peak Oil dates lead to different trends of oil prices, exportation and growth. ► Low short-term prices benefit to the long-term macroeconomy of oil exporters. ► High short-term prices hedge oil importers against economic tensions after Peak Oil.

  18. Characteristic of 120 degree C thermoluminescence peak of iceland spar

    International Nuclear Information System (INIS)

    Lu Xinwei; Han Jia

    2006-01-01

    The basic characteristic of 120 degree C thermoluminescence peak of iceland spar was studied. The experimental result indicates the longevity of 120 degree C thermoluminescence peak of iceland spar is about 2 h under 30 degree C. The thermoluminescence peak moves to the high temperature when the heating speed increasing. The intensity of 120 degree C thermoluminescence peak of iceland spar is directly proportional to radiation dose under 15 Gy. (authors)

  19. Assessing peak aerobic capacity in Dutch law enforcement officers

    NARCIS (Netherlands)

    Wittink, Harriet; Takken, Tim; de Groot, Janke; Reneman, Michiel; Peters, Roelof; Vanhees, Luc

    2015-01-01

    Objectives: To cross-validate the existing peak rate of oxygen consumption (VO2peak) prediction equations in Dutch law enforcement officers and to determine whether these prediction equations can be used to predict VO2peak for groups and in a single individual. A further objective was to report

  20. Determination of the upper limit of a peak area

    International Nuclear Information System (INIS)

    Helene, O.

    1990-03-01

    This paper reports the procedure to extract an upper limit of a peak area in a multichannel spectrum. This procedure takes into account the finite shape of the peak and the uncertanties in the background and in the expected position of the peak. (author) [pt

  1. PEAK TRACKING WITH A NEURAL NETWORK FOR SPECTRAL RECOGNITION

    NARCIS (Netherlands)

    COENEGRACHT, PMJ; METTING, HJ; VANLOO, EM; SNOEIJER, GJ; DOORNBOS, DA

    1993-01-01

    A peak tracking method based on a simulated feed-forward neural network with back-propagation is presented. The network uses the normalized UV spectra and peak areas measured in one chromatogram for peak recognition. It suffices to train the network with only one set of spectra recorded in one

  2. Assessing peak aerobic capacity in Dutch law enforcement officers.

    NARCIS (Netherlands)

    Wittink, H.; Takken, T.; Groot, J.F. de; Reneman, M.; Peters, R.; Vanhees, L.

    2015-01-01

    Objectives: To cross-validate the existing peak rate of oxygen consumption (VO2peak) prediction equations in Dutch law enforcement officers and to determine whether these prediction equations can be used to predict VO2peak for groups and in a single individual. A further objective was to report

  3. 7 CFR 457.163 - Nursery peak inventory endorsement.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Nursery peak inventory endorsement. 457.163 Section... CORPORATION, DEPARTMENT OF AGRICULTURE COMMON CROP INSURANCE REGULATIONS § 457.163 Nursery peak inventory endorsement. Nursery Crop Insurance Peak Inventory Endorsement This endorsement is not continuous and must be...

  4. Bayesian approach for peak detection in two-dimensional chromatography

    NARCIS (Netherlands)

    Vivó-Truyols, G.

    2012-01-01

    A new method for peak detection in two-dimensional chromatography is presented. In a first step, the method starts with a conventional one-dimensional peak detection algorithm to detect modulated peaks. In a second step, a sophisticated algorithm is constructed to decide which of the individual

  5. Determination of the upper limit of a peak area

    International Nuclear Information System (INIS)

    Helene, O.

    1991-01-01

    This article reports the procedure to extract an upper limit of a peak area in a multichannel spectrum. This procedure takes into account the finite shape of the peak and the uncertainties both in the background and in the expected position of the peak. (orig.)

  6. Development of guide thimble stress peaking factor calculation methodology

    International Nuclear Information System (INIS)

    Lee, Seong Ki; Jeon, Sang Youn; Kim, Jae Ik; Jeon, Kyeong Lak; Kim, Kyu Tae

    2004-01-01

    The Nuclear Fuel Assembly for light water reactor which provides for 236 fuel rods consists of guide tubes, spacer grids, top/bottom nozzles. The guide tubes form the main structural components in conjunction with the grids, act as the main load carrying members of fuel assembly and serve as a support structure and a guide path for the control element, neutron sources and incore instruments after they are secured to upper and lower end areas. Top/bottom nozzles make the end parts of fuel assembly. And the spacer girds maintain the fuel rod array by providing positive lateral restraint to the fuel rod to the fuel rod but only frictional restraint to axial fuel rod motion. When the fuel assembly is in reactor, the tensional and compressional forces are applied to guide thimble through the top nozzle. The stresses vary with the location of guide thimble on the top nozzle plate since the different flow plate thickness between center and outer areas causes a different flexibility. The relative stress shall be considered during designing this kind of structure. And it is useful to know a coefficient to represent this relative stress difference and this value is called stress peaking factor

  7. Combined effect of storm movement and drainage network configuration on flood peaks

    Science.gov (United States)

    Seo, Yongwon; Son, Kwang Ik; Choi, Hyun Il

    2016-04-01

    This presentation reports the combined effect of storm movement and drainage network layout on resulting hydrographs and its implication to flood process and also flood mitigation. First, we investigate, in general terms, the effects of storm movement on the resulting flood peaks, and the underlying process controls. For this purpose, we utilize a broad theoretical framework that uses characteristic time and space scales associated with stationary rainstorms as well as moving rainstorms. For a stationary rainstorm the characteristic timescales that govern the peak response include two intrinsic timescales of a catchment and one extrinsic timescale of a rainstorm. On the other hand, for a moving rainstorm, two additional extrinsic scales are required; the storm travel time and storm size. We show that the relationship between the peak response and the timescales appropriate for a stationary rainstorm can be extended in a straightforward manner to describe the peak response for a moving rainstorm. For moving rainstorms, we show that the augmentation of peak response arises from both effect of overlaying the responses from subcatchments (resonance condition) and effect of increased responses from subcatchments due to increased duration (interdependence), which results in maximum peak response when the moving rainstorm is slower than the channel flow velocity. Second, we show the relation between channel network configurations and hydrograph sensitivity to storm kinematics. For this purpose, Gibbs' model is used to evaluate the network characteristics. The results show that the storm kinematics that produces the maximum peak discharge depends on the network configuration because the resonance condition changes with the network configuration. We show that an "efficient" network layout is more sensitive and results in higher increase in peak response compared to "inefficient" one. These results imply different flood potential risks for river networks depending on network

  8. Peak-by-peak correction of Ge(Li) gamma-ray spectra for photopeaks from background

    International Nuclear Information System (INIS)

    Cutshall, N.H.; Larsen, I.L.

    1980-01-01

    Background photopeaks can interfere with accurate measurement of low levels of radionuclides by gamma-ray spectrometry. A flowchart for peak-by-peak correction of sample spectra to produce accurate results is presented. (orig.)

  9. Peak-by-peak correction of Ge(Li) gamma-ray spectra for photopeaks from background

    Energy Technology Data Exchange (ETDEWEB)

    Cutshall, N H; Larsen, I L [Oak Ridge National Lab., TN (USA)

    1980-12-01

    Background photopeaks can interfere with accurate measurement of low levels of radionuclides by gamma-ray spectrometry. A flowchart for peak-by-peak correction of sample spectra to produce accurate results is presented.

  10. Effect of 1,6-hexamethylene diisocyanate exposure on peak flowmetry in automobile paint shop workers in Iran.

    Science.gov (United States)

    Pourabedian, Siyamak; Barkhordari, Abdullah; Habibi, Ehsanallah; Rismanchiyan, Masoud; Zare, Mohsen

    2010-06-01

    The aim of this study was to investigate the effects of occupational exposure to 1,6-hexamethylene diisocyanate (HDI) on peak flowmetry in automobile body paint shop workers in Iran. We studied a population of 43 car painters exposed to HDI at their workplaces. Peak expiratory flow was tested for one working week, from the start to the end of each shift. Air was sampled and HDI analysed in parallel, according to the OSHA 42 method. Daily and weekly HDI exposure averages were (0.42+/-0.1) mg m(-3) and (0.13+/-0.05) mg m(-3), respectively. On painting days, 72 % of workers showed more than a 10 % variation in peak expiratory flow. Inhalation exposure exceeded the threshold limit value (TLV) ten times over. This strongly suggests that HDI affected the peak flowmetry in the studied workers.

  11. Hydroclimatology of Dual Peak Cholera Incidence in Bengal Region: Inferences from a Spatial Explicit Model

    Science.gov (United States)

    Bertuzzo, E.; Mari, L.; Righetto, L.; Casagrandi, R.; Gatto, M.; Rodriguez-Iturbe, I.; Rinaldo, A.

    2010-12-01

    The seasonality of cholera and its relation with environmental drivers are receiving increasing interest and research efforts, yet they remain unsatisfactorily understood. A striking example is the observed annual cycle of cholera incidence in the Bengal region which exhibits two peaks despite the main environmental drivers that have been linked to the disease (air and sea surface temperature, zooplankton density, river discharge) follow a synchronous single-peak annual pattern. A first outbreak, mainly affecting the coastal regions, occurs in spring and it is followed, after a period of low incidence during summer, by a second, usually larger, peak in autumn also involving regions situated farther inland. A hydroclimatological explanation for this unique seasonal cycle has been recently proposed: the low river spring flows favor the intrusion of brackish water (the natural environment of the causative agent of the disease) which, in turn, triggers the first outbreak. The summer rising river discharges have a temporary dilution effect and prompt the repulsion of contaminated water which lowers the disease incidence. However, the monsoon flooding, together with the induced crowding of the population and the failure of the sanitation systems, can possibly facilitate the spatial transmission of the disease and promote the autumn outbreak. We test this hypothesis using a mechanistic, spatially explicit model of cholera epidemic. The framework directly accounts for the role of the river network in transporting and redistributing cholera bacteria among human communities as well as for the annual fluctuation of the river flow. The model is forced with the actual environmental drivers of the region, namely river flow and temperature. Our results show that these two drivers, both having a single peak in the summer, can generate a double peak cholera incidence pattern. Besides temporal patterns, the model is also able to qualitatively reproduce spatial patterns characterized

  12. Automatic Peak Selection by a Benjamini-Hochberg-Based Algorithm

    KAUST Repository

    Abbas, Ahmed; Kong, Xin-Bing; Liu, Zhi; Jing, Bing-Yi; Gao, Xin

    2013-01-01

    A common issue in bioinformatics is that computational methods often generate a large number of predictions sorted according to certain confidence scores. A key problem is then determining how many predictions must be selected to include most of the true predictions while maintaining reasonably high precision. In nuclear magnetic resonance (NMR)-based protein structure determination, for instance, computational peak picking methods are becoming more and more common, although expert-knowledge remains the method of choice to determine how many peaks among thousands of candidate peaks should be taken into consideration to capture the true peaks. Here, we propose a Benjamini-Hochberg (B-H)-based approach that automatically selects the number of peaks. We formulate the peak selection problem as a multiple testing problem. Given a candidate peak list sorted by either volumes or intensities, we first convert the peaks into p-values and then apply the B-H-based algorithm to automatically select the number of peaks. The proposed approach is tested on the state-of-the-art peak picking methods, including WaVPeak [1] and PICKY [2]. Compared with the traditional fixed number-based approach, our approach returns significantly more true peaks. For instance, by combining WaVPeak or PICKY with the proposed method, the missing peak rates are on average reduced by 20% and 26%, respectively, in a benchmark set of 32 spectra extracted from eight proteins. The consensus of the B-H-selected peaks from both WaVPeak and PICKY achieves 88% recall and 83% precision, which significantly outperforms each individual method and the consensus method without using the B-H algorithm. The proposed method can be used as a standard procedure for any peak picking method and straightforwardly applied to some other prediction selection problems in bioinformatics. The source code, documentation and example data of the proposed method is available at http://sfb.kaust.edu.sa/pages/software.aspx. © 2013

  13. Automatic Peak Selection by a Benjamini-Hochberg-Based Algorithm

    KAUST Repository

    Abbas, Ahmed

    2013-01-07

    A common issue in bioinformatics is that computational methods often generate a large number of predictions sorted according to certain confidence scores. A key problem is then determining how many predictions must be selected to include most of the true predictions while maintaining reasonably high precision. In nuclear magnetic resonance (NMR)-based protein structure determination, for instance, computational peak picking methods are becoming more and more common, although expert-knowledge remains the method of choice to determine how many peaks among thousands of candidate peaks should be taken into consideration to capture the true peaks. Here, we propose a Benjamini-Hochberg (B-H)-based approach that automatically selects the number of peaks. We formulate the peak selection problem as a multiple testing problem. Given a candidate peak list sorted by either volumes or intensities, we first convert the peaks into p-values and then apply the B-H-based algorithm to automatically select the number of peaks. The proposed approach is tested on the state-of-the-art peak picking methods, including WaVPeak [1] and PICKY [2]. Compared with the traditional fixed number-based approach, our approach returns significantly more true peaks. For instance, by combining WaVPeak or PICKY with the proposed method, the missing peak rates are on average reduced by 20% and 26%, respectively, in a benchmark set of 32 spectra extracted from eight proteins. The consensus of the B-H-selected peaks from both WaVPeak and PICKY achieves 88% recall and 83% precision, which significantly outperforms each individual method and the consensus method without using the B-H algorithm. The proposed method can be used as a standard procedure for any peak picking method and straightforwardly applied to some other prediction selection problems in bioinformatics. The source code, documentation and example data of the proposed method is available at http://sfb.kaust.edu.sa/pages/software.aspx. © 2013

  14. Peak discharge of a Pleistocene lava-dam outburst flood in Grand Canyon, Arizona, USA

    Science.gov (United States)

    Fenton, Cassandra R.; Webb, Robert H.; Cerling, Thure E.

    2006-03-01

    The failure of a lava dam 165,000 yr ago produced the largest known flood on the Colorado River in Grand Canyon. The Hyaloclastite Dam was up to 366 m high, and geochemical evidence linked this structure to outburst-flood deposits that occurred for 32 km downstream. Using the Hyaloclastite outburst-flood deposits as paleostage indicators, we used dam-failure and unsteady flow modeling to estimate a peak discharge and flow hydrograph. Failure of the Hyaloclastite Dam released a maximum 11 × 10 9 m 3 of water in 31 h. Peak discharges, estimated from uncertainty in channel geometry, dam height, and hydraulic characteristics, ranged from 2.3 to 5.3 × 10 5 m 3 s -1 for the Hyaloclastite outburst flood. This discharge is an order of magnitude greater than the largest known discharge on the Colorado River (1.4 × 10 4 m 3 s -1) and the largest peak discharge resulting from failure of a constructed dam in the USA (6.5 × 10 4 m 3 s -1). Moreover, the Hyaloclastite outburst flood is the oldest documented Quaternary flood and one of the largest to have occurred in the continental USA. The peak discharge for this flood ranks in the top 30 floods (>10 5 m 3 s -1) known worldwide and in the top ten largest floods in North America.

  15. Managing Recurrent Congestion of Subway Network in Peak Hours with Station Inflow Control

    OpenAIRE

    Qingru Zou; Xiangming Yao; Peng Zhao; Fei Dou; Taoyuan Yang

    2018-01-01

    Station inflow control (SIC) is an important and effective method for reducing recurrent congestion during peak hours in the Beijing, Shanghai, and Guangzhou subway systems. This work proposes a practical and efficient method for establishing a static SIC scheme in normal weekdays for large-scale subway networks. First, a traffic assignment model without capacity constraint is utilized to determine passenger flow distributions on the network. An internal relationship between station inflows a...

  16. Plant data comparisons for Comanche Peak 1/2 main feedwater pump trip transient

    Energy Technology Data Exchange (ETDEWEB)

    Boatwright, W.J.; Choe, W.G; Hiltbrand, D.W. [TU Electric, Dallas, TX (United States)] [and others

    1995-09-01

    A RETRAN-02 MOD5 model of Comanche Peak Steam Electric Station was developed by TU Electric for the purpose of performing core reload safety analyses. In order to qualify this model, comparisons against plant transient data from a partial loss of main feedwater flow were performed. These comparisons demonstrated that good representations of the plant response could be obtained with RETRAN-02 and the user-developed models of the primary-to-secondary heat transfer and plant control systems.

  17. Gamma-Ray Peak Integration: Accuracy and Precision

    International Nuclear Information System (INIS)

    Richard M. Lindstrom

    2000-01-01

    The accuracy of singlet gamma-ray peak areas obtained by a peak analysis program is immaterial. If the same algorithm is used for sample measurement as for calibration and if the peak shapes are similar, then biases in the integration method cancel. Reproducibility is the only important issue. Even the uncertainty of the areas computed by the program is trivial because the true standard uncertainty can be experimentally assessed by repeated measurements of the same source. Reproducible peak integration was important in a recent standard reference material certification task. The primary tool used for spectrum analysis was SUM, a National Institute of Standards and Technology interactive program to sum peaks and subtract a linear background, using the same channels to integrate all 20 spectra. For comparison, this work examines other peak integration programs. Unlike some published comparisons of peak performance in which synthetic spectra were used, this experiment used spectra collected for a real (though exacting) analytical project, analyzed by conventional software used in routine ways. Because both components of the 559- to 564-keV doublet are from 76 As, they were integrated together with SUM. The other programs, however, deconvoluted the peaks. A sensitive test of the fitting algorithm is the ratio of reported peak areas. In almost all the cases, this ratio was much more variable than expected from the reported uncertainties reported by the program. Other comparisons to be reported indicate that peak integration is still an imperfect tool in the analysis of gamma-ray spectra

  18. Relationships between electroencephalographic spectral peaks across frequency bands

    Directory of Open Access Journals (Sweden)

    Sacha Jennifer Van Albada

    2013-03-01

    Full Text Available The degree to which electroenencephalographic (EEG spectral peaks are independent, and the relationships between their frequencies have been debated. A novel fitting method was used to determine peak parameters in the range 2–35 Hz from a large sample of eyes-closed spectra, and their interrelationships were investigated. Findings were compared with a mean-field model of thalamocortical activity, which predicts near-harmonic relationships between peaks. The subject set consisted of 1424 healthy subjects from the Brain Resource International Database. Peaks in the theta range occurred on average near half the alpha peak frequency, while peaks in the beta range tended to occur near twice and three times the alpha peak frequency on an individual-subject basis. Moreover, for the majority of subjects, alpha peak frequencies were significantly positively correlated with frequencies of peaks in the theta and low and high beta ranges. Such a harmonic progression agrees semiquantitatively with theoretical predictions from the mean-field model. These findings indicate a common or analogous source for different rhythms, and help to define appropriate individual frequency bands for peak identification.

  19. Relationships between Electroencephalographic Spectral Peaks Across Frequency Bands

    Science.gov (United States)

    van Albada, S. J.; Robinson, P. A.

    2013-01-01

    The degree to which electroencephalographic spectral peaks are independent, and the relationships between their frequencies have been debated. A novel fitting method was used to determine peak parameters in the range 2–35 Hz from a large sample of eyes-closed spectra, and their interrelationships were investigated. Findings were compared with a mean-field model of thalamocortical activity, which predicts near-harmonic relationships between peaks. The subject set consisted of 1424 healthy subjects from the Brain Resource International Database. Peaks in the theta range occurred on average near half the alpha peak frequency, while peaks in the beta range tended to occur near twice and three times the alpha peak frequency on an individual-subject basis. Moreover, for the majority of subjects, alpha peak frequencies were significantly positively correlated with frequencies of peaks in the theta and low and high beta ranges. Such a harmonic progression agrees semiquantitatively with theoretical predictions from the mean-field model. These findings indicate a common or analogous source for different rhythms, and help to define appropriate individual frequency bands for peak identification. PMID:23483663

  20. Particle in cell simulation of peaking switch for breakdown evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Umbarkar, Sachin B.; Bindu, S.; Mangalvedekar, H.A.; Saxena, A.; Singh, N.M., E-mail: sachin.b.umbarkar@gmail.com [Department of Electric Engineering, Veermata Jijabai Technological Institute, Mumbai (India); Sharma, Archana; Saroj, P.C.; Mittal, K.C. [Accelerator Pulse Power Division, Bhabha Atomic Research Centre, Mumbai (India)

    2014-07-01

    Marx generator connected to peaking capacitor and peaking switch can generate Ultra-Wideband (UWB) radiation. A new peaking switch is designed for converting the existing nanosecond Marx generator to a UWB source. The paper explains the particle in cell (PIC) simulation for this peaking switch, using MAGIC 3D software. This peaking switch electrode is made up of copper tungsten material and is fixed inside the hermitically sealed derlin material. The switch can withstand a gas pressure up to 13.5 kg/cm{sup 2}. The lower electrode of the switch is connected to the last stage of the Marx generator. Initially Marx generator (without peaking stage) in air; gives the output pulse with peak amplitude of 113.75 kV and pulse rise time of 25 ns. Thus, we design a new peaking switch to improve the rise time of output pulse and to pressurize this peaking switch separately (i.e. Marx and peaking switch is at different pressure). The PIC simulation gives the particle charge density, current density, E counter plot, emitted electron current, and particle energy along the axis of gap between electrodes. The charge injection and electric field dependence on ionic dissociation phenomenon are briefly analyzed using this simulation. The model is simulated with different gases (N{sub 2}, H{sub 2}, and Air) under different pressure (2 kg/cm{sup 2}, 5 kg/cm{sup 2}, 10 kg/cm{sup 2}). (author)

  1. QRS peak detection for heart rate monitoring on Android smartphone

    Science.gov (United States)

    Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto

    2017-11-01

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.

  2. Evaluation of peak power prediction equations in male basketball players.

    Science.gov (United States)

    Duncan, Michael J; Lyons, Mark; Nevill, Alan M

    2008-07-01

    This study compared peak power estimated using 4 commonly used regression equations with actual peak power derived from force platform data in a group of adolescent basketball players. Twenty-five elite junior male basketball players (age, 16.5 +/- 0.5 years; mass, 74.2 +/- 11.8 kg; height, 181.8 +/- 8.1 cm) volunteered to participate in the study. Actual peak power was determined using a countermovement vertical jump on a force platform. Estimated peak power was determined using countermovement jump height and body mass. All 4 prediction equations were significantly related to actual peak power (all p jump prediction equations, 12% for the Canavan and Vescovi equation, and 6% for the Sayers countermovement jump equation. In all cases peak power was underestimated.

  3. Peak experiences of psilocybin users and non-users.

    Science.gov (United States)

    Cummins, Christina; Lyke, Jennifer

    2013-01-01

    Maslow (1970) defined peak experiences as the most wonderful experiences of a person's life, which may include a sense of awe, well-being, or transcendence. Furthermore, recent research has suggested that psilocybin can produce experiences subjectively rated as uniquely meaningful and significant (Griffiths et al. 2006). It is therefore possible that psilocybin may facilitate or change the nature of peak experiences in users compared to non-users. This study was designed to compare the peak experiences of psilocybin users and non-users, to evaluate the frequency of peak experiences while under the influence of psilocybin, and to assess the perceived degree of alteration of consciousness during these experiences. Participants were recruited through convenience and snowball sampling from undergraduate classes and at a musical event. Participants were divided into three groups, those who reported a peak experience while under the influence of psilocybin (psilocybin peak experience: PPE), participants who had used psilocybin but reported their peak experiences did not occur while they were under the influence of psilocybin (non-psilocybin peak experience: NPPE), and participants who had never used psilocybin (non-user: NU). A total of 101 participants were asked to think about their peak experiences and complete a measure evaluating the degree of alteration of consciousness during that experience. Results indicated that 47% of psilocybin users reported their peak experience occurred while using psilocybin. In addition, there were significant differences among the three groups on all dimensions of alteration of consciousness. Future research is necessary to identify factors that influence the peak experiences of psilocybin users in naturalistic settings and contribute to the different characteristics of peak experiences of psilocybin users and non-users.

  4. Extragalactic Peaked-spectrum Radio Sources at Low Frequencies

    Energy Technology Data Exchange (ETDEWEB)

    Callingham, J. R.; Gaensler, B. M.; Sadler, E. M.; Lenc, E. [Sydney Institute for Astronomy (SIfA), School of Physics, The University of Sydney, NSW 2006 (Australia); Ekers, R. D.; Bell, M. E. [CSIRO Astronomy and Space Science (CASS), Marsfield, NSW 2122 (Australia); Line, J. L. B.; Hancock, P. J.; Kapińska, A. D.; McKinley, B.; Procopio, P. [ARC Centre of Excellence for All-Sky Astrophysics (CAASTRO) (Australia); Hurley-Walker, N.; Tingay, S. J.; Franzen, T. M. O.; Morgan, J. [International Centre for Radio Astronomy Research (ICRAR), Curtin University, Bentley, WA 6102 (Australia); Dwarakanath, K. S. [Raman Research Institute (RRI), Bangalore 560080 (India); For, B.-Q. [International Centre for Radio Astronomy Research (ICRAR), The University of Western Australia, Crawley, WA 6009 (Australia); Hindson, L.; Johnston-Hollitt, M. [School of Chemical and Physical Sciences, Victoria University of Wellington, Wellington 6140 (New Zealand); Offringa, A. R., E-mail: joseph.callingham@sydney.edu.au [Netherlands Institute for Radio Astronomy (ASTRON), Dwingeloo (Netherlands); and others

    2017-02-20

    We present a sample of 1483 sources that display spectral peaks between 72 MHz and 1.4 GHz, selected from the GaLactic and Extragalactic All-sky Murchison Widefield Array (GLEAM) survey. The GLEAM survey is the widest fractional bandwidth all-sky survey to date, ideal for identifying peaked-spectrum sources at low radio frequencies. Our peaked-spectrum sources are the low-frequency analogs of gigahertz-peaked spectrum (GPS) and compact-steep spectrum (CSS) sources, which have been hypothesized to be the precursors to massive radio galaxies. Our sample more than doubles the number of known peaked-spectrum candidates, and 95% of our sample have a newly characterized spectral peak. We highlight that some GPS sources peaking above 5 GHz have had multiple epochs of nuclear activity, and we demonstrate the possibility of identifying high-redshift ( z > 2) galaxies via steep optically thin spectral indices and low observed peak frequencies. The distribution of the optically thick spectral indices of our sample is consistent with past GPS/CSS samples but with a large dispersion, suggesting that the spectral peak is a product of an inhomogeneous environment that is individualistic. We find no dependence of observed peak frequency with redshift, consistent with the peaked-spectrum sample comprising both local CSS sources and high-redshift GPS sources. The 5 GHz luminosity distribution lacks the brightest GPS and CSS sources of previous samples, implying that a convolution of source evolution and redshift influences the type of peaked-spectrum sources identified below 1 GHz. Finally, we discuss sources with optically thick spectral indices that exceed the synchrotron self-absorption limit.

  5. The sharp peak-flat trough pattern and critical speculation

    OpenAIRE

    Roehner, B. M.; Sornette, D.

    1998-01-01

    We find empirically a characteristic sharp peak-flat trough pattern in a large set of commodity prices. We argue that the sharp peak structure reflects an endogenous inter-market organization, and that peaks may be seen as local ``singularities'' resulting from imitation and herding. These findings impose a novel stringent constraint on the construction of models. Intermittent amplification is not sufficient and nonlinear effects seem necessary to account for the observations.

  6. Gamma-ray peak shapes from cadmium zinc telluride detectors

    Energy Technology Data Exchange (ETDEWEB)

    Namboodiri, M.N.; Lavietes, A.D.; McQuaid, J.H.

    1996-09-01

    We report the results of a study of the peak shapes in the gamma spectra measured using several 5 x 5 x 5 mm{sup 3} cadmium zinc telluride (CZT) detectors. A simple parameterization involving a Gaussian and an exponential low energy tail describes the peak shapes sell. We present the variation of the parameters with gamma energy. This type of information is very useful in the analysis of complex gamma spectra consisting of many peaks.

  7. Statistics of peaks in cosmological nonlinear density fields

    International Nuclear Information System (INIS)

    Suginohara, Tatsushi; Suto, Yasushi.

    1990-06-01

    Distribution of the high-density peaks in the universe is examined using N-body simulations. Nonlinear evolution of the underlying density field significantly changes the statistical properties of the peaks, compared with the analytic results valid for the random Gaussian field. In particular, the abundances and correlations of the initial density peaks are discussed in the context of biased galaxy formation theory. (author)

  8. Environmental impacts of public transport. Why peak-period travellers cause a greater environmental burden than off-peak travellers

    International Nuclear Information System (INIS)

    Rietveld, P.

    2002-01-01

    Given the difference between peak and off-peak occupancy rates in public transport, emissions per traveller kilometre are lower in the peak than in the off-peak period, whereas the opposite pattern is observed for cars. It is argued that it is much more fruitful to analyse environmental effects in marginal terms. This calls for a careful analysis of capacity management policies of public transport suppliers that are facing increased demand during both peak and off-peak periods. A detailed analysis of capacity management by the Netherlands Railways (NS) revealed that off-peak capacity supply is mainly dictated by the demand levels during the peak period. The analysis included the effects of increased frequency and increased vehicle size on environmental impacts, while environmental economies of vehicle size were also taken into account. The main conclusion is that the marginal environmental burden during the peak hours is much higher than is usually thought, whereas it is almost zero during the off-peak period. This implies a pattern that is the precise opposite of the average environmental burden. Thus, an analysis of environmental effects of public transport based on average performance would yield misleading conclusions [nl

  9. Evaluation of peak-fitting software for gamma spectrum analysis

    International Nuclear Information System (INIS)

    Zahn, Guilherme S.; Genezini, Frederico A.; Moralles, Mauricio

    2009-01-01

    In all applications of gamma-ray spectroscopy, one of the most important and delicate parts of the data analysis is the fitting of the gamma-ray spectra, where information as the number of counts, the position of the centroid and the width, for instance, are associated with each peak of each spectrum. There's a huge choice of computer programs that perform this type of analysis, and the most commonly used in routine work are the ones that automatically locate and fit the peaks; this fit can be made in several different ways - the most common ways are to fit a Gaussian function to each peak or simply to integrate the area under the peak, but some software go far beyond and include several small corrections to the simple Gaussian peak function, in order to compensate for secondary effects. In this work several gamma-ray spectroscopy software are compared in the task of finding and fitting the gamma-ray peaks in spectra taken with standard sources of 137 Cs, 60 Co, 133 Ba and 152 Eu. The results show that all of the automatic software can be properly used in the task of finding and fitting peaks, with the exception of GammaVision; also, it was possible to verify that the automatic peak-fitting software did perform as well as - and sometimes even better than - a manual peak-fitting software. (author)

  10. Individual vision and peak distribution in collective actions

    Science.gov (United States)

    Lu, Peng

    2017-06-01

    People make decisions on whether they should participate as participants or not as free riders in collective actions with heterogeneous visions. Besides of the utility heterogeneity and cost heterogeneity, this work includes and investigates the effect of vision heterogeneity by constructing a decision model, i.e. the revised peak model of participants. In this model, potential participants make decisions under the joint influence of utility, cost, and vision heterogeneities. The outcomes of simulations indicate that vision heterogeneity reduces the values of peaks, and the relative variance of peaks is stable. Under normal distributions of vision heterogeneity and other factors, the peaks of participants are normally distributed as well. Therefore, it is necessary to predict distribution traits of peaks based on distribution traits of related factors such as vision heterogeneity and so on. We predict the distribution of peaks with parameters of both mean and standard deviation, which provides the confident intervals and robust predictions of peaks. Besides, we validate the peak model of via the Yuyuan Incident, a real case in China (2014), and the model works well in explaining the dynamics and predicting the peak of real case.

  11. Bayesian approach for peak detection in two-dimensional chromatography.

    Science.gov (United States)

    Vivó-Truyols, Gabriel

    2012-03-20

    A new method for peak detection in two-dimensional chromatography is presented. In a first step, the method starts with a conventional one-dimensional peak detection algorithm to detect modulated peaks. In a second step, a sophisticated algorithm is constructed to decide which of the individual one-dimensional peaks have been originated from the same compound and should then be arranged in a two-dimensional peak. The merging algorithm is based on Bayesian inference. The user sets prior information about certain parameters (e.g., second-dimension retention time variability, first-dimension band broadening, chromatographic noise). On the basis of these priors, the algorithm calculates the probability of myriads of peak arrangements (i.e., ways of merging one-dimensional peaks), finding which of them holds the highest value. Uncertainty in each parameter can be accounted by adapting conveniently its probability distribution function, which in turn may change the final decision of the most probable peak arrangement. It has been demonstrated that the Bayesian approach presented in this paper follows the chromatographers' intuition. The algorithm has been applied and tested with LC × LC and GC × GC data and takes around 1 min to process chromatograms with several thousands of peaks.

  12. simulation of vertical water flow through vadose zone

    African Journals Online (AJOL)

    HOD

    Simulation of vertical water flow representing the release of water from the vadose zone to the aquifer of surroundings ... ground water pollution from agricultural, industrial and municipal .... Peak Flow Characteristics of Wyoming. Streams: US ...

  13. Assessing peak aerobic capacity in Dutch law enforcement officers

    Directory of Open Access Journals (Sweden)

    Harriet Wittink

    2015-06-01

    Full Text Available Objectives: To cross-validate the existing peak rate of oxygen consumption (VO2peak prediction equations in Dutch law enforcement officers and to determine whether these prediction equations can be used to predict VO2peak for groups and in a single individual. A further objective was to report normative absolute and relative VO2peak values of a sample of law enforcement officers in the Netherlands. Material and Methods: The peak rate of oxygen consumption (ml×kg–1×min–1 was measured using a maximal incremental bicycle test in 1530 subjects, including 1068 male and 461 female police officers. Validity of the prediction equations for groups was assessed by comparing predicted VO2peak with measured VO2peak using paired t-tests. For individual differences limits of agreement (LoA were calculated. Equations were considered valid for individuals when the difference between measured and predicted VO2peak did not exceed ±1 metabolic equivalent (MET in 95% of individuals. Results: None of the equations met the validity criterion of 95% of individuals having ±1 MET difference or less than the measured value. Limits of agreement (LoAs were large in all predictions. At the individual level, none of the equations were valid predictors of VO2peak (ml×kg–1×min–1. Normative values for Dutch law enforcement officers were presented. Conclusions: Substantial differences between measured and predicted VO2peak (ml×kg–1×min–1 were found. Most tested equations were invalid predictors of VO2peak at group level and all were invalid at individual levels.

  14. Constraining the shape of the CMB: A peak-by-peak analysis

    International Nuclear Information System (INIS)

    Oedman, Carolina J.; Hobson, Michael P.; Lasenby, Anthony N.; Melchiorri, Alessandro

    2003-01-01

    The recent measurements of the power spectrum of cosmic microwave background anisotropies are consistent with the simplest inflationary scenario and big bang nucleosynthesis constraints. However, these results rely on the assumption of a class of models based on primordial adiabatic perturbations, cold dark matter and a cosmological constant. In this paper we investigate the need for deviations from the Λ-CDM scenario by first characterizing the spectrum using a phenomenological function in a 15 dimensional parameter space. Using a Monte Carlo Markov chain approach to Bayesian inference and a low curvature model template we then check for the presence of new physics and/or systematics in the CMB data. We find an almost perfect consistency between the phenomenological fits and the standard Λ-CDM models. The curvature of the secondary peaks is weakly constrained by the present data, but they are well located. The improved spectral resolution expected from future satellite experiments is warranted for a definitive test of the scenario

  15. Limitations of middle cerebral artery peak systolic velocity in the ...

    African Journals Online (AJOL)

    We present a case of a mother with severe pre-eclampsia at 32 weeks' gestation and non-immune fetal hydrops without obvious cause. Since the. MCA peak systolic velocity (PSV) was ... Limitations of middle cerebral artery peak systolic velocity .... [7] found MCA PSV of value in 9 women with chronic abruption, but in 5.

  16. Daily Nigerian peak load forecasting using artificial neural network ...

    African Journals Online (AJOL)

    A daily peak load forecasting technique that uses artificial neural network with seasonal indices is presented in this paper. A neural network of relatively smaller size than the main prediction network is used to predict the daily peak load for a period of one year over which the actual daily load data are available using one ...

  17. Diffraction peaks in x-ray spectroscopy: Friend or foe?

    International Nuclear Information System (INIS)

    Tissot, R.G.; Goehner, R.P.

    1992-01-01

    Diffraction peaks can occur as unidentifiable peaks in the energy spectrum of an x-ray spectrometric analysis. Recently, there has been increased interest in oriented polycrystalline films and epitaxial films on single crystal substrates for electronic applications. Since these materials diffract x-rays more efficiently than randomly oriented polycrystalline materials, diffraction peaks are being observed more frequently in x-ray fluorescent spectra. In addition, micro x-ray spectrometric analysis utilizes a small, intense, collimated x-ray beam that can yield well defined diffraction peaks. In some cases these diffraction peaks can occur at the same position as elemental peaks. These diffraction peaks, although a possible problem in qualitative and quantitative elemental analysis, can give very useful information about the crystallographic structure and orientation of the material being analyzed. The observed diffraction peaks are dependent on the geometry of the x-ray spectrometer, the degree of collimation and the distribution of wavelengths (energies) originating from the x-ray tube and striking the sample

  18. Quality Assurance in the Determination of Overlapping Peak Areas

    DEFF Research Database (Denmark)

    Christensen, L.H.; Heydorn, K.

    1987-01-01

    The ability of different computer programs to yield accurate peak areas in statistical control in the case of partially overlapping photopeaks has been tested by the Analysis of Precision. A modified Covell method, two commercially available peak-fitting programs from Nuclear Data and Ortec, and ...

  19. Peak effect in surface resistance at microwave frequencies in Dy ...

    Indian Academy of Sciences (India)

    In the measurements at both frequencies the induced microwave current was always less than the critical current of the films. The reason for observation of this peak effect in these films has been explained in our earlier publication [5]. Comparing figures 1 and 2, it is observed that the peaks in sample S1 are broader and.

  20. Peak heart rate decreases with increasing severity of acute hypoxia

    DEFF Research Database (Denmark)

    Lundby, C; Araoz, M; Van Hall, Gerrit

    2001-01-01

    , 459, and 404 mmHg) in a hypobaric chamber and while breathing 9% O(2) in N(2). These conditions were equivalent to altitudes of 3300, 4300, 5300, and 6300 m above sea level, respectively. At 4300 m, maximal exercise was also repeated after 4 and 8 h. Peak heart rate (HR) decreased from 191 (182......-202) (mean and range) at sea level to 189 (179-200), 182 (172-189), 175 (166-183), and 165 (162-169) in the acute hypoxic conditions. Peak HR did not decrease further after 4 and 8 h at 4300 m compared to the acute exposure at this altitude. Between barometric pressures of 518 and 355 mmHg (approximately...... 3300 and 6300 m), peak HR decreased linearly: peak HR(hypobaria) = peak HR(sea level) - 0.135 x [hypobaria(3100) - hypobaria (mmHg)]; or peak HR(altitude) = peak HR(sea level) - 0.15 x (altitude - 3100 m). This corresponds to approximately 1-beat x min(-1) reduction in peak HR for every 7-mmHg decrease...

  1. Determination of gaussian peaks in gamma spectra by iterative regression

    International Nuclear Information System (INIS)

    Nordemann, D.J.R.

    1987-05-01

    The parameters of the peaks in gamma-ray spectra are determined by a simple iterative regression method. For each peak, the parameters are associated with a gaussian curve (3 parameters) located above a linear continuum (2 parameters). This method may produces the complete result of the calculation of statistical uncertainties and an accuracy higher than others methods. (author) [pt

  2. Online junction temperature measurement using peak gate current

    DEFF Research Database (Denmark)

    Baker, Nick; Munk-Nielsen, Stig; Iannuzzo, Francesco

    2015-01-01

    A new method for junction temperature measurement of MOS-gated power semiconductor switches is presented. The measurement method involves detecting the peak voltage over the external gate resistor of an IGBT or MOSFET during turn-on. This voltage is directly proportional to the peak gate current...

  3. Psychological Preparation for Peak Performance in Sports Competition

    Science.gov (United States)

    Ohuruogu, Ben; Jonathan, Ugwuanyi I.; Ikechukwu, Ugwu Jude

    2016-01-01

    This paper attempts to make an overview of various techniques, sport psychologist adopt in psychological preparation of athletes for peak performance. To attain peak performance in sports competitions, coaches and athletes should not base their prospect on physical training on sport skills alone rather should integrate both the mental and physical…

  4. Identification of peaks in multidimensional coincidence {gamma}-ray spectra

    Energy Technology Data Exchange (ETDEWEB)

    Morhac, Miroslav E-mail: fyzimiro@savba.sk; Kliman, Jan; Matousek, Vladislav; Veselsky, Martin; Turzo, Ivan

    2000-03-21

    In the paper a new algorithm to find peaks in two, three and multidimensional spectra, measured in large multidetector {gamma}-ray arrays, is derived. Given the dimension m, the algorithm is selective to m-fold coincidence peaks. It is insensitive to intersections of lower-fold coincidences, hereinafter called ridges.

  5. Identification of peaks in multidimensional coincidence γ-ray spectra

    International Nuclear Information System (INIS)

    Morhac, Miroslav; Kliman, Jan; Matousek, Vladislav; Veselsky, Martin; Turzo, Ivan

    2000-01-01

    In the paper a new algorithm to find peaks in two, three and multidimensional spectra, measured in large multidetector γ-ray arrays, is derived. Given the dimension m, the algorithm is selective to m-fold coincidence peaks. It is insensitive to intersections of lower-fold coincidences, hereinafter called ridges

  6. Probabilistic peak detection for first-order chromatographic data

    NARCIS (Netherlands)

    Lopatka, M.; Vivó-Truyols, G.; Sjerps, M.J.

    2014-01-01

    We present a novel algorithm for probabilistic peak detection in first-order chromatographic data. Unlike conventional methods that deliver a binary answer pertaining to the expected presence or absence of a chromatographic peak, our method calculates the probability of a point being affected by

  7. A new automatic fixed peak technology of microcontroller

    International Nuclear Information System (INIS)

    Huang Liguo; Wang Dequan; Zhang Damin; Li Jun; Liu Yuwen; Guo Qingxue; Wang Guifeng

    1999-01-01

    The microcontroller automatic fixed peak technology which differs from fashion half channel fixed peak is described. It bases on the principles of selecting double single channel and readjusting the voltage of power source. This technology is suitable to the industrial isotope instruments with various radioactive sources

  8. Impact of Smart Grid Technologies on Peak Load to 2050

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    The IEA's Smart Grids Technology Roadmap identified five global trends that could be effectively addressed by deploying smart grids. These are: increasing peak load (the maximum power that the grid delivers during peak hours), rising electricity consumption, electrification of transport, deployment of variable generation technologies (e.g. wind and solar PV) and ageing infrastructure. Along with this roadmap, a new working paper -- Impact of Smart Grid Technologies on Peak Load to 2050 -- develops a methodology to estimate the evolution of peak load until 2050. It also analyses the impact of smart grid technologies in reducing peak load for four key regions; OECD North America, OECD Europe, OECD Pacific and China. This working paper is a first IEA effort in an evolving modelling process of smart grids that is considering demand response in residential and commercial sectors as well as the integration of electric vehicles.

  9. Redshift space correlations and scale-dependent stochastic biasing of density peaks

    Science.gov (United States)

    Desjacques, Vincent; Sheth, Ravi K.

    2010-01-01

    We calculate the redshift space correlation function and the power spectrum of density peaks of a Gaussian random field. Our derivation, which is valid on linear scales k≲0.1hMpc-1, is based on the peak biasing relation given by Desjacques [Phys. Rev. DPRVDAQ1550-7998, 78, 103503 (2008)10.1103/PhysRevD.78.103503]. In linear theory, the redshift space power spectrum is Ppks(k,μ)=exp⁡(-f2σvel2k2μ2)[bpk(k)+bvel(k)fμ2]2Pδ(k), where μ is the angle with respect to the line of sight, σvel is the one-dimensional velocity dispersion, f is the growth rate, and bpk(k) and bvel(k) are k-dependent linear spatial and velocity bias factors. For peaks, the value of σvel depends upon the functional form of bvel. When the k dependence is absent from the square brackets and bvel is set to unity, the resulting expression is assumed to describe models where the bias is linear and deterministic, but the velocities are unbiased. The peak model is remarkable because it has unbiased velocities in this same sense—peak motions are driven by dark matter flows—but, in order to achieve this, bvel must be k dependent. We speculate that this is true in general: k dependence of the spatial bias will lead to k dependence of bvel even if the biased tracers flow with the dark matter. Because of the k dependence of the linear bias parameters, standard manipulations applied to the peak model will lead to k-dependent estimates of the growth factor that could erroneously be interpreted as a signature of modified dark energy or gravity. We use the Fisher formalism to show that the constraint on the growth rate f is degraded by a factor of 2 if one allows for a k-dependent velocity bias of the peak type. Our analysis also demonstrates that the Gaussian smoothing term is part and parcel of linear theory. We discuss a simple estimate of nonlinear evolution and illustrate the effect of the peak bias on the redshift space multipoles. For k≲0.1hMpc-1, the peak bias is deterministic but k

  10. How would peak rainfall intensity affect runoff predictions using conceptual water balance models?

    Directory of Open Access Journals (Sweden)

    B. Yu

    2015-06-01

    Full Text Available Most hydrological models use continuous daily precipitation and potential evapotranspiration for streamflow estimation. With the projected increase in mean surface temperature, hydrological processes are set to intensify irrespective of the underlying changes to the mean precipitation. The effect of an increase in rainfall intensity on the long-term water balance is, however, not adequately accounted for in the commonly used hydrological models. This study follows from a previous comparative analysis of a non-stationary daily series of stream flow of a forested watershed (River Rimbaud in the French Alps (area = 1.478 km2 (1966–2006. Non-stationarity in the recorded stream flow occurred as a result of a severe wild fire in 1990. Two daily models (AWBM and SimHyd were initially calibrated for each of three distinct phases in relation to the well documented land disturbance. At the daily and monthly time scales, both models performed satisfactorily with the Nash–Sutcliffe coefficient of efficiency (NSE varying from 0.77 to 0.92. When aggregated to the annual time scale, both models underestimated the flow by about 22% with a reduced NSE at about 0.71. Exploratory data analysis was undertaken to relate daily peak hourly rainfall intensity to the discrepancy between the observed and modelled daily runoff amount. Preliminary results show that the effect of peak hourly rainfall intensity on runoff prediction is insignificant, and model performance is unlikely to improve when peak daily precipitation is included. Trend analysis indicated that the large decrease of precipitation when daily precipitation amount exceeded 10–20 mm may have contributed greatly to the decrease in stream flow of this forested watershed.

  11. Flood frequency analysis for nonstationary annual peak records in an urban drainage basin

    Science.gov (United States)

    Villarini, G.; Smith, J.A.; Serinaldi, F.; Bales, J.; Bates, P.D.; Krajewski, W.F.

    2009-01-01

    Flood frequency analysis in urban watersheds is complicated by nonstationarities of annual peak records associated with land use change and evolving urban stormwater infrastructure. In this study, a framework for flood frequency analysis is developed based on the Generalized Additive Models for Location, Scale and Shape parameters (GAMLSS), a tool for modeling time series under nonstationary conditions. GAMLSS is applied to annual maximum peak discharge records for Little Sugar Creek, a highly urbanized watershed which drains the urban core of Charlotte, North Carolina. It is shown that GAMLSS is able to describe the variability in the mean and variance of the annual maximum peak discharge by modeling the parameters of the selected parametric distribution as a smooth function of time via cubic splines. Flood frequency analyses for Little Sugar Creek (at a drainage area of 110 km2) show that the maximum flow with a 0.01-annual probability (corresponding to 100-year flood peak under stationary conditions) over the 83-year record has ranged from a minimum unit discharge of 2.1 m3 s- 1 km- 2 to a maximum of 5.1 m3 s- 1 km- 2. An alternative characterization can be made by examining the estimated return interval of the peak discharge that would have an annual exceedance probability of 0.01 under the assumption of stationarity (3.2 m3 s- 1 km- 2). Under nonstationary conditions, alternative definitions of return period should be adapted. Under the GAMLSS model, the return interval of an annual peak discharge of 3.2 m3 s- 1 km- 2 ranges from a maximum value of more than 5000 years in 1957 to a minimum value of almost 8 years for the present time (2007). The GAMLSS framework is also used to examine the links between population trends and flood frequency, as well as trends in annual maximum rainfall. These analyses are used to examine evolving flood frequency over future decades. ?? 2009 Elsevier Ltd.

  12. Flood frequency analysis for nonstationary annual peak records in an urban drainage basin

    Science.gov (United States)

    Villarini, Gabriele; Smith, James A.; Serinaldi, Francesco; Bales, Jerad; Bates, Paul D.; Krajewski, Witold F.

    2009-08-01

    Flood frequency analysis in urban watersheds is complicated by nonstationarities of annual peak records associated with land use change and evolving urban stormwater infrastructure. In this study, a framework for flood frequency analysis is developed based on the Generalized Additive Models for Location, Scale and Shape parameters (GAMLSS), a tool for modeling time series under nonstationary conditions. GAMLSS is applied to annual maximum peak discharge records for Little Sugar Creek, a highly urbanized watershed which drains the urban core of Charlotte, North Carolina. It is shown that GAMLSS is able to describe the variability in the mean and variance of the annual maximum peak discharge by modeling the parameters of the selected parametric distribution as a smooth function of time via cubic splines. Flood frequency analyses for Little Sugar Creek (at a drainage area of 110km) show that the maximum flow with a 0.01-annual probability (corresponding to 100-year flood peak under stationary conditions) over the 83-year record has ranged from a minimum unit discharge of 2.1mskm to a maximum of 5.1mskm. An alternative characterization can be made by examining the estimated return interval of the peak discharge that would have an annual exceedance probability of 0.01 under the assumption of stationarity (3.2mskm). Under nonstationary conditions, alternative definitions of return period should be adapted. Under the GAMLSS model, the return interval of an annual peak discharge of 3.2mskm ranges from a maximum value of more than 5000 years in 1957 to a minimum value of almost 8 years for the present time (2007). The GAMLSS framework is also used to examine the links between population trends and flood frequency, as well as trends in annual maximum rainfall. These analyses are used to examine evolving flood frequency over future decades.

  13. INTERFERENCE AS AN ORIGIN OF THE PEAKED NOISE IN ACCRETING X-RAY BINARIES

    Energy Technology Data Exchange (ETDEWEB)

    Veledina, Alexandra, E-mail: alexandra.veledina@gmail.com [Nordita, KTH Royal Institute of Technology and Stockholm University, Roslagstullsbacken 23, SE-10691 Stockholm (Sweden)

    2016-12-01

    We propose a physical model for the peaked noise in the X-ray power density spectra of accreting X-ray binaries. We interpret its appearance as an interference of two Comptonization continua: one coming from the upscattering of seed photons from the cold thin disk and the other fed by the synchrotron emission of the hot flow. Variations of both X-ray components are caused by fluctuations in mass accretion rate, but there is a delay between them corresponding to the propagation timescale from the disk Comptonization radius to the region of synchrotron Comptonization. If the disk and synchrotron Comptonization are correlated, the humps in the power spectra are harmonically related and the dips between them appear at frequencies related as odd numbers 1:3:5. If they are anti-correlated, the humps are related as 1:3:5, but the dips are harmonically related. Similar structures are expected to be observed in accreting neutron star binaries and supermassive black holes. The delay can be easily recovered from the frequency of peaked noise and further used to constrain the combination of the viscosity parameter and disk height-to-radius ratio α ( H / R ){sup 2} of the accretion flow. We model multi-peak power spectra of black hole X-ray binaries GX 339–4 and XTE J1748–288 to constrain these parameters.

  14. Ground penetrating radar and seismic refraction investigation of fracture patterns in the basalt of Lucky Peak near Boise, Idaho

    International Nuclear Information System (INIS)

    Dougherty, M.E.; Hudson, W.K.; Kay, S.E.; Vincent, R.J.

    1994-01-01

    In hard rock environments, fluid flow and basement integrity are often controlled by the degree and connectivity of fracturing on an outcrop scale, rather than strictly by laboratory values of the permeability and competence of the matrix rock. Therefore, in many cases it is important to have a subsurface image of fracture characteristics of rock units in addition to an image of gross rock type. Fortunately, within a single rock type, many physical properties on outcrop scale are greatly influenced by fracturing, and changes in these physical properties should be detectable through the innovative use of geophysical methods. Work presented here is an attempt to use surface geophysical methods to delineate areas within a basalt flow which display different fracture characteristics and which have different electrical and seismic properties. The Basalt of Luck Peak is an intracanyon basalt flow exposed in cliffs around Lucky Peak Reservoir and in a terrace downstream from Lucky Peak Dam near Boise, Idaho. Visible in the face of the terrace below Lucky Peak Dam are the colonnade and entablature structures characteristic of differential cooling rates within basalt flows. Exposure of structural units within the cliff face is used to ground truth results from ground penetrating radar (GPR) and seismic refraction data collected along a line running perpendicular and away from the top edge of the cliff. 19 refs., 6 figs

  15. Peak broadening in paper chromatography and related techniques : III. Peak broadening in thin-layer chromatography on cellulose powder

    NARCIS (Netherlands)

    Ligny, C.L. de; Remijnse, A.G.

    1968-01-01

    The mechanism of peak broadening in thin-layer chromatography on cellulose powder was investigated by comparing the peak widths obtained in chromatography with those caused only by diffusion in the cellulose powder, for a set of amino acids of widely differing RF values and six kinds of cellulose

  16. Evaluation of different time domain peak models using extreme learning machine-based peak detection for EEG signal.

    Science.gov (United States)

    Adam, Asrul; Ibrahim, Zuwairie; Mokhtar, Norrima; Shapiai, Mohd Ibrahim; Cumming, Paul; Mubin, Marizan

    2016-01-01

    Various peak models have been introduced to detect and analyze peaks in the time domain analysis of electroencephalogram (EEG) signals. In general, peak model in the time domain analysis consists of a set of signal parameters, such as amplitude, width, and slope. Models including those proposed by Dumpala, Acir, Liu, and Dingle are routinely used to detect peaks in EEG signals acquired in clinical studies of epilepsy or eye blink. The optimal peak model is the most reliable peak detection performance in a particular application. A fair measure of performance of different models requires a common and unbiased platform. In this study, we evaluate the performance of the four different peak models using the extreme learning machine (ELM)-based peak detection algorithm. We found that the Dingle model gave the best performance, with 72 % accuracy in the analysis of real EEG data. Statistical analysis conferred that the Dingle model afforded significantly better mean testing accuracy than did the Acir and Liu models, which were in the range 37-52 %. Meanwhile, the Dingle model has no significant difference compared to Dumpala model.

  17. THE EFFECTS OF AREA CONTRACTION ON SHOCK WAVE STRENGTH AND PEAK PRESSURE IN SHOCK TUBE

    Directory of Open Access Journals (Sweden)

    A. M. Mohsen

    2012-06-01

    Full Text Available This paper presents an experimental investigation into the effects of area contraction on shock wave strength and peak pressure in a shock tube. The shock tube is an important component of the short duration, high speed fluid flow test facility, available at the Universiti Tenaga Nasional (UNITEN, Malaysia. The area contraction was facilitated by positioning a bush adjacent to the primary diaphragm section, which separates the driver and driven sections. Experimental measurements were performed with and without the presence of the bush, at various diaphragm pressure ratios, which is the ratio of air pressure between the driver (high pressure and driven (low pressure sections. The instantaneous static pressure variations were measured at two locations close to the driven tube end wall, using high sensitivity pressure sensors, which allow the shock wave strength, shock wave speed and peak pressure to be analysed. The results reveal that the area contraction significantly reduces the shock wave strength, shock wave speed and peak pressure. At a diaphragm pressure ratio of 10, the shock wave strength decreases by 18%, the peak pressure decreases by 30% and the shock wave speed decreases by 8%.

  18. Operational and structural measures to reduce hydro-peaking impact on fish larvae

    International Nuclear Information System (INIS)

    Kopecki, Ianina; Schneider, Matthias

    2016-01-01

    Eco-hydraulic investigations studying the effects of hydro-peaking on river biota are gaining in importance. Negative effects of rapid flow fluctuations due to hydro power production are well documented by many studies, with the larvae and juvenile fish identified among the mostly affected life stages. Therefore, elaboration of efficient hydro-peaking mitigation strategies is an important issue for energy companies as well as for water body administrations responsible for the fulfilment of WFD requirements. The present case study strives for practical solutions allowing to minimize or compensate the negative effects of hydro-peaking on the fish fauna of the 7 km long river reach on the river Lech (southern Germany). Model based investigations allow to access the impact from currently authorized discharge regime, suggest operational and structural measures within the reach in terms of reducing the risk of stranding for fish larvae and select the measures most easy to implement and with the largest ecological benefit. The paper describes the approach for accessing the effects of hydro-peaking based on 2D hydrodynamic modelling, fuzzy logic based habitat modelling and information on cutting-edge biological investigations on fish larvae from Lunz experimental facility (Austria). (authors)

  19. System dynamics model of Hubbert Peak for China's oil

    International Nuclear Information System (INIS)

    Tao Zaipu; Li Mingyu

    2007-01-01

    American geophysicist M. King Hubbert in 1956 first introduced a logistic equation to estimate the peak and lifetime production for oil of USA. Since then, a fierce debate ensued on the so-called Hubbert Peak, including also its methodology. This paper proposes to use the generic STELLA model to simulate Hubbert Peak, particularly for the Chinese oil production. This model is demonstrated as being robust. We used three scenarios to estimate the Chinese oil peak: according to scenario 1 of this model, the Hubbert Peak for China's crude oil production appears to be in 2019 with a value of 199.5 million tonnes, which is about 1.1 times the 2005 output. Before the peak comes, Chinese oil output will grow by about 1-2% annually, after the peak, however, the output will fall. By 2040, the annual production of Chinese crude oil would be equivalent to the level of 1990. During the coming 20 years, the crude oil demand of China will probably grow at the rate of 2-3% annually, and the gap between domestic supply and total demand may be more than half of this demand

  20. Core fueling to produce peaked density profiles in large tokamaks

    International Nuclear Information System (INIS)

    Mikkelsen, D.R.; McGuire, K.M.; Schmidt, G.L.; Zweben, S.J.

    1994-06-01

    Peaking the density profile increases the usable bootstrap current and the average fusion power density; this could reduce the current drive power and increase the net output of power producing tokamaks. The use of neutral beams and pellet injection to produce peaked density profiles is assessed. We show that with radially ''hollow'' diffusivity profiles (and no particle pinch) moderately peaked density profiles can be produced by particle source profiles which are peaked off-axis. The fueling penetration requirements can therefore be relaxed and this greatly improves the feasibility of generating peaked density profiles in large tokamaks. In particular, neutral beam fueling does not require MeV particle energy. Even with beam voltages of ∼200 keV, however, exceptionally good particle confinement, τ p much-gt τ E is required to achieve net electrical power generation. In system with no power production requirement (e.g., neutron sources) neutral beam fueling should be capable of producing peaked density profiles in devices as large as ITER. Fueling systems with low energy cost per particle (such as cryogenic pellet injection) must be used in power producing tokamaks when τ p ∼ τ E . Simulations with pellet injection speeds of 7 km/sec show the peaking factor, n eo /left-angle n e right-angle, approaching 2

  1. Probabilistic peak detection for first-order chromatographic data.

    Science.gov (United States)

    Lopatka, M; Vivó-Truyols, G; Sjerps, M J

    2014-03-19

    We present a novel algorithm for probabilistic peak detection in first-order chromatographic data. Unlike conventional methods that deliver a binary answer pertaining to the expected presence or absence of a chromatographic peak, our method calculates the probability of a point being affected by such a peak. The algorithm makes use of chromatographic information (i.e. the expected width of a single peak and the standard deviation of baseline noise). As prior information of the existence of a peak in a chromatographic run, we make use of the statistical overlap theory. We formulate an exhaustive set of mutually exclusive hypotheses concerning presence or absence of different peak configurations. These models are evaluated by fitting a segment of chromatographic data by least-squares. The evaluation of these competing hypotheses can be performed as a Bayesian inferential task. We outline the potential advantages of adopting this approach for peak detection and provide several examples of both improved performance and increased flexibility afforded by our approach. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Core fuelling to produce peaked density profiles in large tokamaks

    International Nuclear Information System (INIS)

    Mikkelsen, D.R.; McGuire, K.M.; Schmidt, G.L.; Zweben, S.J.

    1995-01-01

    Peaking the density profile increases the usable bootstrap current and the average fusion power density; this could reduce the current drive power and increase the net output of power producing tokamaks. The use of neutral beams and pellet injection to produce peaked density profiles is assessed. It is shown that with radially 'hollow' diffusivity profiles (and no particle pinch) moderately peaked density profiles can be produced by particle source profiles that are peaked off-axis. The fuelling penetration requirements can therefore be relaxed and this greatly improves the feasibility of generating peaked density profiles in large tokamaks. In particular, neutral beam fuelling does not require Megavolt particle energies. Even with beam voltages of ∼ 200 keV, however, exceptionally good particle confinement is needed to achieve net electrical power generation. The required ratio of particle to thermal diffusivities is an order of magnitude outside the range reported for tokamaks. In a system with no power production requirement (e.g., neutron sources) neutral beam fuelling should be capable of producing peaked density profiles in devices as large as ITER. Fuelling systems with low energy cost per particle - such as cryogenic pellet injection - must be used in power producing tokamaks when τ P ∼ τ E . Simulations with pellet injection speeds of 7 km/s show that the peaking factor, n e0 / e >, approaches 2. (author). 65 refs, 8 figs

  3. Peak nasal inspiratory flow as outcome for provocation studies in allergen exposure chambers

    DEFF Research Database (Denmark)

    Boelke, Georg; Berger, Uwe; Bergmann, Karl-Christian

    2017-01-01

    : In a randomized controlled blinded setting subjects suffering from allergic rhinitis were exposed to grass pollen, birch pollen, house dust mite and/or placebo in the GA(2)LEN chamber. Different allergen concentrations were used to evaluate symptom severities. Patients had to perform PNIF before and every 30 min...... during a challenge using a portable PNIF meter. RESULTS: 86 subjects participated in 203 challenges, altogether. House dust mite provocations caused the greatest reduction in PNIF values, followed by grass pollen and birch pollen. Provocations with every allergen or pollen concentration led...... symptoms. CONCLUSION: PNIF is a helpful and feasible tool for conducting provocation trials with allergens, especially grass pollen and house dust mite, in an AEC....

  4. Evaluation of Peak Expiratory Flow rates (PEFR) of Workers in a ...

    African Journals Online (AJOL)

    Background: Occupational lung diseases (OLD) remain one of the most common workplace health challenges since the industrial revolution. One of the risks for OLD is the exposure to cement dust which is associated with varying degrees of respiratory symptoms and reduction in lung function. This study aimed to measure ...

  5. Precipitation-snowmelt timing and snowmelt augmentation of large peak flow events, western Cascades, Oregon

    Science.gov (United States)

    Keith Jennings; Julia A. Jones

    2015-01-01

    This study tested multiple hydrologic mechanisms to explain snowpack dynamics in extreme rain-on-snow floods, which occur widely in the temperate and polar regions. We examined 26, 10 day large storm events over the period 1992–2012 in the H.J. Andrews Experimental Forest in western Oregon, using statistical analyses (regression, ANOVA, and wavelet coherence) of hourly...

  6. Peak Expiratory Flow as a Surrogate for Health Related Quality of ...

    African Journals Online (AJOL)

    Spirometry was done using American Thoracic Society's standards and reference equations from African American norms of the US population. Quality of life was measured with the St George's Respiratory Questionnaire (SGRQ) Results: Out of 50 patients recruited for the study, 48 provided complete data with acceptable ...

  7. Daily changes of peak expiratory flow and respiratory symptom occurrence around a soy processing factory

    NARCIS (Netherlands)

    Heederik, Dick; Doekes, Gert; van Strien, Rob; Brunekreef, Bert

    2014-01-01

    Objectives. To evaluate sensitization and acute respiratory health effects in inhabitants living in the vicinity of a factory producing soy oil. Methods. Two panels of potential responders were created on the basis of a response to a short screening questionnaire sent to random samples of 1,000

  8. Peak loads and network investments in sustainable energy transitions

    Energy Technology Data Exchange (ETDEWEB)

    Blokhuis, Erik, E-mail: e.g.j.blokhuis@tue.nl [Eindhoven University of Technology, Department of Architecture, Building and Planning, Vertigo 8.11, P.O. Box 513, 5600MB Eindhoven (Netherlands); Brouwers, Bart [Eindhoven University of Technology, Department of Architecture, Building and Planning, Vertigo 8.11, P.O. Box 513, 5600MB Eindhoven (Netherlands); Putten, Eric van der [Endinet, Gas and Electricity Network Operations, P.O. Box 2005, 5600CA Eindhoven (Netherlands); Schaefer, Wim [Eindhoven University of Technology, Department of Architecture, Building and Planning, Vertigo 8.11, P.O. Box 513, 5600MB Eindhoven (Netherlands)

    2011-10-15

    Current energy distribution networks are often not equipped for facilitating expected sustainable transitions. Major concerns for future electricity networks are the possibility of peak load increases and the expected growth of decentralized energy generation. In this article, we focus on peak load increases; the effects of possible future developments on peak loads are studied, together with the consequences for the network. The city of Eindhoven (the Netherlands) is used as reference city, for which a scenario is developed in which the assumed future developments adversely influence the maximum peak loads on the network. In this scenario, the total electricity peak load in Eindhoven is expected to increase from 198 MVA in 2009 to 591-633 MVA in 2040. The necessary investments for facilitating the expected increased peak loads are estimated at 305-375 million Euros. Based upon these projections, it is advocated that - contrary to current Dutch policy - choices regarding sustainable transitions should be made from the viewpoint of integral energy systems, evaluating economic implications of changes to generation, grid development, and consumption. Recently applied and finished policies on energy demand reduction showed to be effective; however, additional and connecting policies on energy generation and distribution should be considered on short term. - Highlights: > Sustainable energy transitions can result in major electricity peak load increases. > Introduction of heat pumps and electrical vehicles requires network expansion. > Under worst case assumptions, peak loads in Eindhoven increase with 200% until 2040. > The necessary investment for facilitating this 2040 peak demand is Euro 305-375 million. > Future policy choices should be made from the viewpoint of the integral energy system.

  9. Peak loads and network investments in sustainable energy transitions

    International Nuclear Information System (INIS)

    Blokhuis, Erik; Brouwers, Bart; Putten, Eric van der; Schaefer, Wim

    2011-01-01

    Current energy distribution networks are often not equipped for facilitating expected sustainable transitions. Major concerns for future electricity networks are the possibility of peak load increases and the expected growth of decentralized energy generation. In this article, we focus on peak load increases; the effects of possible future developments on peak loads are studied, together with the consequences for the network. The city of Eindhoven (the Netherlands) is used as reference city, for which a scenario is developed in which the assumed future developments adversely influence the maximum peak loads on the network. In this scenario, the total electricity peak load in Eindhoven is expected to increase from 198 MVA in 2009 to 591-633 MVA in 2040. The necessary investments for facilitating the expected increased peak loads are estimated at 305-375 million Euros. Based upon these projections, it is advocated that - contrary to current Dutch policy - choices regarding sustainable transitions should be made from the viewpoint of integral energy systems, evaluating economic implications of changes to generation, grid development, and consumption. Recently applied and finished policies on energy demand reduction showed to be effective; however, additional and connecting policies on energy generation and distribution should be considered on short term. - Highlights: → Sustainable energy transitions can result in major electricity peak load increases. → Introduction of heat pumps and electrical vehicles requires network expansion. → Under worst case assumptions, peak loads in Eindhoven increase with 200% until 2040. → The necessary investment for facilitating this 2040 peak demand is Euro 305-375 million. → Future policy choices should be made from the viewpoint of the integral energy system.

  10. Relaxation peak near 200 K in NiTi alloy

    Science.gov (United States)

    Zhu, J. S.; Schaller, R.; Benoit, W.

    1989-10-01

    Internal friction (IF), frequency ( f), electrical resistance ( R) and zero point movement of the torsion pendulum (ɛ) have been measured in near equi-atomic NiTi alloy in order to clarify the mechanism for the relaxation peak near 200 K. The height of the relaxation peak decreases successively with thermal cycling and settles down to a lower stable value in running 15 cycles. However, the electrical resistance of the sample shows a variation in contrast with the internal friction. Both of them will return to the initial state after a single annealing at 773 K for 1 h. The probable mechanism of this relaxation peak was discussed.

  11. National energy peak leveling program (NEPLP). Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    This three-volume report is responsive to the requirements of Contract E (04-3)-1152 to provide a detailed methodology, to include management, technology, and socio-economic aspects, of a voluntary community program of computer-assisted peak load leveling and energy conservation in commercial community facilities. The demonstration project established proof-of-concept in reducing the kW-demand peak by the unofficial goal of 10%, with concurrent kWh savings. This section of the three volume report is a final report appendix with information on the National Energy Peak Leveling Program (NEPLP).

  12. The environmental impacts of peaking at hydropower plants

    International Nuclear Information System (INIS)

    Halleraker, Jo Halvard

    2001-01-01

    A recent energy act in Norway allows hydropower plants to be operated so that hydro peaking is permitted. However, it is uncertain how fish react to the variations in discharge and depth that follow hydro peaking. SINTEF Energy Research is cooperating with other research institutions to investigate the consequences of these variations on the biota. Among the research tools is an aqua channel which is an indoor laboratory flume where fish behaviour can be studied in detail. It has been constructed to provide the hydropower industry and public authorities with means of better determining the effects of hydro peaking. (author)

  13. On the nature of low temperature internal friction peaks in metallic glasses

    International Nuclear Information System (INIS)

    Khonik, V.A.; Spivak, L.V.

    1996-01-01

    Low temperature (30 60 Nb 40 subjected to preliminary inhomogeneous deformation by cold rolling, homogeneous tensile deformation or electrolytic charging with hydrogen is investigated. Cold rolling or hydrogenation result in appearance of similar internal friction peaks and hysteresis damping. Homogeneous deformation has no influence on low temperature internal friction. The phenomenon of microplastic deformation during hydrogenation of weakly stressed samples is revealed. It is argued that microplastic deformation of metallic glasses during hydrogenation without external stress takes place too. Plastic flow both on cold rolling and hydrogenation occurs via formation and motion of dislocation-like defects which are the reason of the observed anelastic anomalies. It is concluded that low temperature internal friction peaks described in the literature for as-cast, cold deformed and hydrogenated samples have common dislocation-like origin

  14. On the nature of low temperature internal friction peaks in metallic glasses

    Energy Technology Data Exchange (ETDEWEB)

    Khonik, V.A. [State Pedagogical Univ., Voronezh (Russian Federation); Spivak, L.V. [State Univ., Perm (Russian Federation)

    1996-01-01

    Low temperature (30 < T < 300 K) internal friction in a metallic glass Ni{sub 60}Nb{sub 40} subjected to preliminary inhomogeneous deformation by cold rolling, homogeneous tensile deformation or electrolytic charging with hydrogen is investigated. Cold rolling or hydrogenation result in appearance of similar internal friction peaks and hysteresis damping. Homogeneous deformation has no influence on low temperature internal friction. The phenomenon of microplastic deformation during hydrogenation of weakly stressed samples is revealed. It is argued that microplastic deformation of metallic glasses during hydrogenation without external stress takes place too. Plastic flow both on cold rolling and hydrogenation occurs via formation and motion of dislocation-like defects which are the reason of the observed anelastic anomalies. It is concluded that low temperature internal friction peaks described in the literature for as-cast, cold deformed and hydrogenated samples have common dislocation-like origin.

  15. Some infant ventilators do not limit peak inspiratory pressure reliably during active expiration.

    Science.gov (United States)

    Kirpalani, H; Santos-Lyn, R; Roberts, R

    1988-09-01

    In order to minimize barotrauma in newborn infants with respiratory failure, peak inspiratory pressures should not exceed those required for adequate gas exchange. We examined whether four commonly used pressure-limited, constant flow ventilators limit pressure reliably during simulated active expiration against the inspiratory stroke of the ventilator. Three machines of each type were tested at 13 different expiratory flow rates (2 to 14 L/min). Flow-dependent pressure overshoot above a dialed pressure limit of 20 cm H2O was observed in all machines. However, the magnitude differed significantly between ventilators from different manufacturers (p = .0009). Pressure overshoot above 20 cm H2O was consistently lowest in the Healthdyne (0.8 cm H2O at 2 L/min, 3.6 cm H2O at 14 L/min) and highest in the Bourns BP200 (3.0 cm H2O at 2 L/min, 15.4 cm H2O at 14 L/min). We conclude that peak inspiratory pressure overshoots on pressure-limited ventilators occur during asynchronous expiration. This shortcoming may contribute to barotrauma in newborn infants who "fight" positive-pressure ventilation.

  16. PolyaPeak: Detecting Transcription Factor Binding Sites from ChIP-seq Using Peak Shape Information

    Science.gov (United States)

    Wu, Hao; Ji, Hongkai

    2014-01-01

    ChIP-seq is a powerful technology for detecting genomic regions where a protein of interest interacts with DNA. ChIP-seq data for mapping transcription factor binding sites (TFBSs) have a characteristic pattern: around each binding site, sequence reads aligned to the forward and reverse strands of the reference genome form two separate peaks shifted away from each other, and the true binding site is located in between these two peaks. While it has been shown previously that the accuracy and resolution of binding site detection can be improved by modeling the pattern, efficient methods are unavailable to fully utilize that information in TFBS detection procedure. We present PolyaPeak, a new method to improve TFBS detection by incorporating the peak shape information. PolyaPeak describes peak shapes using a flexible Pólya model. The shapes are automatically learnt from the data using Minorization-Maximization (MM) algorithm, then integrated with the read count information via a hierarchical model to distinguish true binding sites from background noises. Extensive real data analyses show that PolyaPeak is capable of robustly improving TFBS detection compared with existing methods. An R package is freely available. PMID:24608116

  17. The peak of oil production-Timings and market recognition

    International Nuclear Information System (INIS)

    Almeida, Pedro de; Silva, Pedro D.

    2009-01-01

    Energy is essential for present societies. In particular, transportation systems depend on petroleum-based fuels. That world oil production is set to pass a peak is now a reasonably accepted concept, although its date is far from consensual. In this work, we analyze the true expectations of the oil market participants about the future availability of this fundamental energy source. We study the evolution through time of the curves of crude oil futures prices, and we conclude that the market participants, among them the crude oil producers, already expect a near-term peak of oil production. This agrees with many technical predictions for the date of peak production, including our own, that point to peak dates around the end of the present decade. If this scenario is confirmed, it can cause serious social and economical problems because societies will have little time to perform the necessary adjustments

  18. Reducing Electricity Demand Peaks by Scheduling Home Appliances Usage

    DEFF Research Database (Denmark)

    Rossello Busquet, Ana; Kardaras, Georgios; Iversen, Villy Bæk

    2011-01-01

    Nowadays there is a tendency to consume electricity during the same period of the day leading to demand peaks. Regular energy consumption habits lead to demand peaks at specific temporal intervals, because users consume power at the same time. In order to avoid demand peaks, users’ appliances...... should consume electricity in a more temporarily distributed way. A new methodology to schedule the usage of home appliances is proposed and analyzed in this paper. The main concept behind this approach is the aggregation of home appliances into priority classes and the definition of a maximum power...... consumption limit, which is not allowed to be exceeded during peak hours. The scenario simulated describes a modern household, where the electrical devices are classified in low and high priority groups. The high priority devices are always granted power in order to operate without temporal restrictions...

  19. Advancements of ultra-high peak power laser diode arrays

    Science.gov (United States)

    Crawford, D.; Thiagarajan, P.; Goings, J.; Caliva, B.; Smith, S.; Walker, R.

    2018-02-01

    Enhancements of laser diode epitaxy in conjunction with process and packaging improvements have led to the availability of 1cm bars capable of over 500W peak power at near-infrared wavelengths (770nm to 1100nm). Advances in cooler design allow for multi-bar stacks with bar-to-bar pitches as low as 350μm and a scalable package architecture enabled a single diode assembly with total peak powers of over 1MegaWatt of peak power. With the addition of micro-optics, overall array brightness greater than 10kW/cm2 was achieved. Performance metrics of barbased diode lasers specifically engineered for high peak power and high brightness at wavelengths and pulse conditions commonly used to pump a variety of fiber and solid-state materials are presented.

  20. Improving EEG signal peak detection using feature weight learning ...

    Indian Academy of Sciences (India)

    Asrul Adam

    4 School of Psychology and Counseling, Queensland University of Technology, Brisbane 4000, Australia. 5 QIMR ... The groups of Acir et al .... difference between the peak and the floating mean, which is ..... Thus, the individual features were.

  1. Energy and public health: the challenge of peak petroleum.

    Science.gov (United States)

    Frumkin, Howard; Hess, Jeremy; Vindigni, Stephen

    2009-01-01

    Petroleum is a unique and essential energy source, used as the principal fuel for transportation, in producing many chemicals, and for numerous other purposes. Global petroleum production is expected to reach a maximum in the near future and to decline thereafter, a phenomenon known as "peak petroleum." This article reviews petroleum geology and uses, describes the phenomenon of peak petroleum, and reviews the scientific literature on the timing of this transition. It then discusses how peak petroleum may affect public health and health care, by reference to four areas: medical supplies and equipment, transportation, energy generation, and food production. Finally, it suggests strategies for anticipating and preparing for peak petroleum, both general public health preparedness strategies and actions specific to the four expected health system impacts.

  2. OECD : Euroopa peaks laenuraha odava hoidma / Sirje Rank

    Index Scriptorium Estoniae

    Rank, Sirje, 1966-

    2002-01-01

    USA majanduse kiire toibumine võib varsti tuua laenuintresside tõusu, Euroopa Keskpank peaks vähemalt aasta lõpuni ootama ja laskma kasvul juurduda. Diagramm: OECD tõstis majanduskasvu prognoosi. Maksukoormus

  3. Hubbert's Oil Peak Revisited by a Simulation Model

    International Nuclear Information System (INIS)

    Giraud, P.N.; Sutter, A.; Denis, T.; Leonard, C.

    2010-01-01

    As conventional oil reserves are declining, the debate on the oil production peak has become a burning issue. An increasing number of papers refer to Hubbert's peak oil theory to forecast the date of the production peak, both at regional and world levels. However, in our views, this theory lacks micro-economic foundations. Notably, it does not assume that exploration and production decisions in the oil industry depend on market prices. In an attempt to overcome these shortcomings, we have built an adaptative model, accounting for the behavior of one agent, standing for the competitive exploration-production industry, subjected to incomplete but improving information on the remaining reserves. Our work yields challenging results on the reasons for an Hubbert type peak oil, lying mainly 'above the ground', both at regional and world levels, and on the shape of the production and marginal cost trajectories. (authors)

  4. Peak globalization. Climate change, oil depletion and global trade

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, Fred [Department of Economics, Drew University, Madison, NJ 07940 (United States)

    2009-12-15

    The global trade in goods depends upon reliable, inexpensive transportation of freight along complex and long-distance supply chains. Global warming and peak oil undermine globalization by their effects on both transportation costs and the reliable movement of freight. Countering the current geographic pattern of comparative advantage with higher transportation costs, climate change and peak oil will thus result in peak globalization, after which the volume of exports will decline as measured by ton-miles of freight. Policies designed to mitigate climate change and peak oil are very unlikely to change this result due to their late implementation, contradictory effects and insufficient magnitude. The implication is that supply chains will become shorter for most products and that production of goods will be located closer to where they are consumed. (author)

  5. Peak thrust operation of linear induction machines from parameter identification

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Z.; Eastham, T.R.; Dawson, G.E. [Queen`s Univ., Kingston, Ontario (Canada). Dept. of Electrical and Computer Engineering

    1995-12-31

    Various control strategies are being used to achieve high performance operation of linear drives. To maintain minimum volume and weight of the power supply unit on board the transportation vehicle, peak thrust per unit current operation is a desirable objective. True peak thrust per unit current through slip control is difficult to achieve because the parameters of linear induction machines vary during normal operation. This paper first develops a peak thrust per unit current control law based on the per-phase equivalent circuit for linear induction machines. The algorithm for identification of the variable parameters in induction machines is then presented. Application to an operational linear induction machine (LIM) demonstrates the utility of this algorithm. The control strategy is then simulated, based on an operational transit LIM, to show the capability of achieving true peak thrust operation for linear induction machines.

  6. Brian Eno Hollandi Festivali peakülaliseks

    Index Scriptorium Estoniae

    1999-01-01

    Inglise helilooja, videokunstnik ja muusikaprodutsent Brian Eno on 5.-26. juunini Amsterdamis toimuva avangardse Hollandi Festivali peakülaline, kelle videoinstallatsioon seatakse üles Stedelijki Muuseumis. Festivali programmist

  7. FHWA operations support : port peak pricing program evaluation

    Science.gov (United States)

    2009-01-01

    This report evaluates the applicability, Federal policy implications, and possible public and private sector roles related to peak pricing strategies at ports and intermodal facilities in the U.S. A number of ports and intermodal terminals are consid...

  8. Peak globalization. Climate change, oil depletion and global trade

    International Nuclear Information System (INIS)

    Curtis, Fred

    2009-01-01

    The global trade in goods depends upon reliable, inexpensive transportation of freight along complex and long-distance supply chains. Global warming and peak oil undermine globalization by their effects on both transportation costs and the reliable movement of freight. Countering the current geographic pattern of comparative advantage with higher transportation costs, climate change and peak oil will thus result in peak globalization, after which the volume of exports will decline as measured by ton-miles of freight. Policies designed to mitigate climate change and peak oil are very unlikely to change this result due to their late implementation, contradictory effects and insufficient magnitude. The implication is that supply chains will become shorter for most products and that production of goods will be located closer to where they are consumed. (author)

  9. The simple method of determination peaks areas in multiplets

    International Nuclear Information System (INIS)

    Loska, L.; Ptasinski, J.

    1991-01-01

    Semiconductor germanium detectors used in γ-spectrometry give spectra with well-separated peaks. However, in some cases, energies of γ-lines are too near, to produce resolved and undisturbed peaks. Then, there is a necessity to perform a mathematical separation. The method proposed here is based on the assumption, that areas of peaks composing the analysed multiplet are proportional to their heights. The method can be applied for any number of interfering peaks, providing, that the function of the background under the multiplet is accurately determined. The results of testing calculations performed on a simulated spectrum are given. The method works successfully in a computer program used for neutron activation analysis data processing. (author). 9 refs, 1 fig, 1 tab

  10. Heavy Ion Testing at the Galactic Cosmic Ray Energy Peak

    Science.gov (United States)

    Pellish, Jonathan A.; Xapsos, M. A.; LaBel, K. A.; Marshall, P. W.; Heidel, D. F.; Rodbell, K. P.; Hakey, M. C.; Dodd, P. E.; Shaneyfelt, M. R.; Schwank, J. R.; hide

    2009-01-01

    A 1 GeV/u Fe-56 Ion beam allows for true 90 deg. tilt irradiations of various microelectronic components and reveals relevant upset trends for an abundant element at the galactic cosmic ray (GCR) flux-energy peak.

  11. Bedrock Geologic Map of the Jay Peak, VT Quadrangle

    Data.gov (United States)

    Vermont Center for Geographic Information — Digital data from VG99-1 Compilation bedrock geologic map of the Jay Peak quadrangle, Compiled by B. Doolan, 1999: VGS Open-File Report VG99-1, 1 plate, scale...

  12. Neutron-induced peaks in Ge detectors from evaporation neutrons

    International Nuclear Information System (INIS)

    Gete, E.; Measday, D.F.; Moftah, B.A.; Saliba, M.A.; Stocki, T.J.

    1997-01-01

    We have studied the peak shapes at 596 and 691 keV resulting from fast neutron interactions inside germanium detectors. We have used neutrons from a 252 Cf source, as well as from the 28 Si(μ - , nν), and 209 Bi(π - , xn) reactions to compare the peaks and to check for a dependence of peak shape on the incoming neutron energy. In our investigation, no difference between these three measurements has been observed. In a comparison of these peak shapes with other studies, we found similar results to ours except for those measurements using monoenergetic neutrons in which a significant variation with neutron energy has been observed. (orig.)

  13. Desert Peak East Enhanced Geothermal Systems (EGS) Project

    Energy Technology Data Exchange (ETDEWEB)

    Zemach, Ezra [Ormat Technologies Inc., Reno, NV (United States); Drakos, Peter [Ormat Technologies Inc., Reno, NV (United States); Spielman, Paul [Ormat Technologies Inc., Reno, NV (United States); Akerley, John [Ormat Technologies Inc., Reno, NV (United States)

    2013-09-30

    This manuscript is a draft to replaced with a final version at a later date TBD. A summary of activities pertaining to the Desert Peak EGS project including the planning and resulting stimulation activities.

  14. Periodic transmission peak splitting in one dimensional disordered photonic structures

    Science.gov (United States)

    Kriegel, Ilka; Scotognella, Francesco

    2016-08-01

    In the present paper we present ways to modulate the periodic transmission peaks arising in disordered one dimensional photonic structures with hundreds of layers. Disordered structures in which the optical length nd (n is the refractive index and d the layer thickness) is the same for each layer show regular peaks in their transmission spectra. A proper variation of the optical length of the layers leads to a splitting of the transmission peaks. Notably, the variation of the occurrence of high and low refractive index layers, gives a tool to tune also the width of the peaks. These results are of highest interest for optical application, such as light filtering, where the manifold of parameters allows a precise design of the spectral transmission ranges.

  15. Peak-load management, the security of supply warranty

    International Nuclear Information System (INIS)

    2010-01-01

    Even if France owns an efficient power generation park, largely exporting and clean (90% with no CO 2 emission), it encounters some difficulties during peak-load periods. The successive peak power demand records which are recorded each year represent as many alerts about a possible collapse of the power system. In order to warrant the electricity supply, the present day regulatory framework must be changed to allow the industrial players to carry out the necessary investments

  16. Improvements to science operations at Kitt Peak National Observatory

    Science.gov (United States)

    Bohannan, Bruce

    1998-07-01

    In recent years Kitt Peak National Observatory has undertaken a number of innovative projects to optimize science operations with the suite of telescopes we operate on Kitt Peak, Arizona. Changing scientific requirements and expectations of our users, evolving technology and declining budgets have motivated the changes. The operations improvements have included telescope performance enhancements--with the focus on the Mayall 4-m--modes of observing and scheduling, telescope control and observing systems, planning and communication, and data archiving.

  17. Several peaks of total current in Trichel pulse

    International Nuclear Information System (INIS)

    Bolotov, O.; Golota, V.; Kadolin, B.; Mankovskyi, S.; Ostroushko, V.; Pashchenko, I.; Taran, G.; Zavada, L.

    2015-01-01

    The numerical simulations of negative corona at constant voltage in Trichel pulse mode are carried out in assumptions of presence and absence of photoemission from cathode. In absence of photoemission two peaks of total current or the step before the main peak were obtained for very small values of ion-electron emission coefficient. In presence of photoemission there were observed several maximums, connected with instability development of the process based on radiation of photons, photoemission, and avalanche multiplication

  18. Converter for Measurement of non-sinusoidal current peak value

    DEFF Research Database (Denmark)

    Butvin, P.; Nielsen, Otto V; Brauer, Peter

    1997-01-01

    A linear-response toroid with core wound of rapidly quenched soft magnetic metallic ribbon and fitted with two windings is used to enable correct measurement of mean peak value of non-sinusoidal and not noise-free alternating current.......A linear-response toroid with core wound of rapidly quenched soft magnetic metallic ribbon and fitted with two windings is used to enable correct measurement of mean peak value of non-sinusoidal and not noise-free alternating current....

  19. Generation of narrow peaks in spectroscopy of charged particles

    Energy Technology Data Exchange (ETDEWEB)

    Dubbers, Dirk, E-mail: dubbers@physi.uni-heidelberg.de; Schmidt, Ulrich, E-mail: ulrich.schmidt@physi.uni-heidelberg.de

    2016-11-21

    In spectroscopy of charged particles, narrow peaks may appear in continuous spectra if magnetic transport of the particles is involved. These artefacts, which so far have escaped the attention of investigators, can develop whenever geometric detection efficiency is less than 100%. As such peaks may be misinterpreted as new physics, their generation is investigated, both analytically and experimentally, for various detector configurations, including those used in searches for the spontaneous decay of the vacuum in heavy-ion collisions.

  20. Modeling the probability distribution of peak discharge for infiltrating hillslopes

    Science.gov (United States)

    Baiamonte, Giorgio; Singh, Vijay P.

    2017-07-01

    Hillslope response plays a fundamental role in the prediction of peak discharge at the basin outlet. The peak discharge for the critical duration of rainfall and its probability distribution are needed for designing urban infrastructure facilities. This study derives the probability distribution, denoted as GABS model, by coupling three models: (1) the Green-Ampt model for computing infiltration, (2) the kinematic wave model for computing discharge hydrograph from the hillslope, and (3) the intensity-duration-frequency (IDF) model for computing design rainfall intensity. The Hortonian mechanism for runoff generation is employed for computing the surface runoff hydrograph. Since the antecedent soil moisture condition (ASMC) significantly affects the rate of infiltration, its effect on the probability distribution of peak discharge is investigated. Application to a watershed in Sicily, Italy, shows that with the increase of probability, the expected effect of ASMC to increase the maximum discharge diminishes. Only for low values of probability, the critical duration of rainfall is influenced by ASMC, whereas its effect on the peak discharge seems to be less for any probability. For a set of parameters, the derived probability distribution of peak discharge seems to be fitted by the gamma distribution well. Finally, an application to a small watershed, with the aim to test the possibility to arrange in advance the rational runoff coefficient tables to be used for the rational method, and a comparison between peak discharges obtained by the GABS model with those measured in an experimental flume for a loamy-sand soil were carried out.

  1. Peak oil: The four stages of a new idea

    Energy Technology Data Exchange (ETDEWEB)

    Bardi, Ugo [Dipartimento di Chimica, Universita di Firenze, Association for the Study of Peak Oil and Gas (ASPO), Polo Scientifico di Sesto Fiorentino, Via della Lastruccia 3, 50019 Sesto Fiorentino (Fi) (Italy)

    2009-03-15

    The present paper reviews the reactions and the path of acceptance of the theory known as ''peak oil''. The theory was proposed for the first time by M.K. Hubbert in the 1950s as a way to describe the production pattern of crude oil. According to Hubbert, the production curve is ''bell shaped'' and approximately symmetric. Hubbert's theory was verified with good approximation for the case of oil production in the United States that peaked in 1971, and is now being applied to the worldwide oil production. It is generally believed that the global peak of oil production (''peak oil'') will take place during the first decade of the 21st century, and some analysts believe that it has already occurred in 2005 or 2006. The theory and its consequences have unpleasant social and economical implications. The present paper is not aimed at assessing the peak date but offers a discussion on the factors that affect the acceptance and the diffusion of the concept of ''peak oil'' with experts and with the general public. The discussion is based on a subdivision of ''four stages of acceptance'', loosely patterned after a sentence by Thomas Huxley. (author)

  2. Peaking of world oil production: Impacts, mitigation, & risk management

    Energy Technology Data Exchange (ETDEWEB)

    Hirsch, R.L. (SAIC); Bezdek, Roger (MISI); Wendling, Robert (MISI)

    2005-02-01

    The peaking of world oil production presents the U.S. and the world with an unprecedented risk management problem. As peaking is approached, liquid fuel prices and price volatility will increase dramatically, and, without timely mitigation, the economic, social, and political costs will be unprecedented. Viable mitigation options exist on both the supply and demand sides, but to have substantial impact, they must be initiated more than a decade in advance of peaking.... The purpose of this analysis was to identify the critical issues surrounding the occurrence and mitigation of world oil production peaking. We simplified many of the complexities in an effort to provide a transparent analysis. Nevertheless, our study is neither simple nor brief. We recognize that when oil prices escalate dramatically, there will be demand and economic impacts that will alter our simplified assumptions. Consideration of those feedbacks will be a daunting task but one that should be undertaken. Our aim in this study is to-- • Summarize the difficulties of oil production forecasting; • Identify the fundamentals that show why world oil production peaking is such a unique challenge; • Show why mitigation will take a decade or more of intense effort; • Examine the potential economic effects of oil peaking; • Describe what might be accomplished under three example mitigation scenarios. • Stimulate serious discussion of the problem, suggest more definitive studies, and engender interest in timely action to mitigate its impacts.

  3. Peak energy consumption and CO2 emissions in China

    International Nuclear Information System (INIS)

    Yuan, Jiahai; Xu, Yan; Hu, Zheng; Zhao, Changhong; Xiong, Minpeng; Guo, Jingsheng

    2014-01-01

    China is in the processes of rapid industrialization and urbanization. Based on the Kaya identity, this paper proposes an analytical framework for various energy scenarios that explicitly simulates China's economic development, with a prospective consideration on the impacts of urbanization and income distribution. With the framework, China's 2050 energy consumption and associated CO 2 reduction scenarios are constructed. Main findings are: (1) energy consumption will peak at 5200–5400 million tons coal equivalent (Mtce) in 2035–2040; (2) CO 2 emissions will peak at 9200–9400 million tons (Mt) in 2030–2035, whilst it can be potentially reduced by 200–300 Mt; (3) China's per capita energy consumption and per capita CO 2 emission are projected to peak at 4 tce and 6.8 t respectively in 2020–2030, soon after China steps into the high income group. - Highlights: • A framework for modeling China's energy and CO 2 emissions is proposed. • Scenarios are constructed based on various assumptions on the driving forces. • Energy consumption will peak in 2035–2040 at 5200–5400 Mtce. • CO 2 emissions will peak in 2030–2035 at about 9300 Mt and be cut by 300 Mt in a cleaner energy path. • Energy consumption and CO 2 emissions per capita will peak soon after China steps into the high income group

  4. Devolatilization kinetics of woody biomass at short residence times and high heating rates and peak temperatures

    DEFF Research Database (Denmark)

    Johansen, Joakim M.; Gadsbøll, Rasmus; Thomsen, Jesper

    2016-01-01

    This work combines experimental and computational fluid dynamics (CFD) results to derive global kinetics for biomass (pine wood) devolatilization during heating rates on the order of 105Ks-1, bulk flow peak temperatures between 1405 and 1667K, and particle residence times below 0.1s. Experiments......Jmol-1. The accuracy of the derived global kinetics was supported by comparing predictions to experimental results from a 15kW furnace. The work emphasizes the importance of characterizing the temperature history of the biomass particles when deriving pyrolysis kinetics. The present results indicate...

  5. Simultaneous collection method of on-peak window image and off-peak window image in Tl-201 imaging

    International Nuclear Information System (INIS)

    Murakami, Tomonori; Noguchi, Yasushi; Kojima, Akihiro; Takagi, Akihiro; Matsumoto, Masanori

    2007-01-01

    Tl-201 imaging detects the photopeak (71 keV, in on-peak window) of characteristic X-rays of Hg-201 formed from Tl-201 decay. The peak is derived from 4 rays of different energy and emission intensity and does not follow in Gaussian distribution. In the present study, authors made an idea for the method in the title to attain the more effective single imaging, which was examined for its accuracy and reliability with phantoms and applied clinically to Tl-201 scintigraphy in a patient. The authors applied the triple energy window method for data acquisition: the energy window setting was made on Hg-201 X-rays photopeak in three of the lower (3%, L), main (72 keV, M) and upper (14%, U) windows with the gamma camera with 2-gated detector (Toshiba E. CAM/ICON). L, M and U images obtained simultaneously were then constructed to images of on-peak (L+M, Mock on-peak) and off-peak (M+U) window settings for evaluation. Phantoms for line source with Tl-201-containing swab and for multi-defect with acrylic plate containing Tl-201 solution were imaged in water. The female patient with thyroid cancer was subjected to preoperative scintigraphy under the defined conditions. Mock on-, off-peak images were found to be equivalent to the true (ordinary, clinical) on-, off-peak ones, and the present method was thought usable for evaluation of usefulness of off-peak window data. (R.T.)

  6. Automatic fitting of Gaussian peaks using abductive machine learning

    Science.gov (United States)

    Abdel-Aal, R. E.

    1998-02-01

    Analytical techniques have been used for many years for fitting Gaussian peaks in nuclear spectroscopy. However, the complexity of the approach warrants looking for machine-learning alternatives where intensive computations are required only once (during training), while actual analysis on individual spectra is greatly simplified and quickened. This should allow the use of simple portable systems for fast and automated analysis of large numbers of spectra, particularly in situations where accuracy may be traded for speed and simplicity. This paper proposes the use of abductive networks machine learning for this purpose. The Abductory Induction Mechanism (AIM) tool was used to build models for analyzing both single and double Gaussian peaks in the presence of noise depicting statistical uncertainties in collected spectra. AIM networks were synthesized by training on 1000 representative simulated spectra and evaluated on 500 new spectra. A classifier network determines the multiplicity of single/double peaks with an accuracy of 5.8%. With statistical uncertainties corresponding to a peak count of 100, average percentage absolute errors for the height, position, and width of single peaks are 4.9, 2.9, and 4.2%, respectively. For double peaks, these average errors are within 7.0, 3.1, and 5.9%, respectively. Models have been developed which account for the effect of a linear background on a single peak. Performance is compared with a neural network application and with an analytical curve-fitting routine, and the new technique is applied to actual data of an alpha spectrum.

  7. The duration of pubertal growth peak among three skeletal classes

    Directory of Open Access Journals (Sweden)

    Waqar Jeelani

    Full Text Available ABSTRACT Introduction: Pubertal growth peak is closely associated with a rapid increase in mandibular length and offers a wide range of therapeutic modifiability. Objective: The aim of the present study was to determine and compare the mean ages of onset and duration of pubertal growth peak among three skeletal classes. Methods: A retrospective cross-sectional study was conducted using lateral cephalograms of 230 subjects with growth potential (110 males, 120 females. Subjects were categorized into three classes (Class I = 81, Class II = 82, Class III = 67, according to the sagittal relationship established between the maxilla and the mandible. The cervical vertebral maturation stage was recorded by means of Baccetti's method. The mean ages at CS3 and CS4 and the CS3-CS4 age interval were compared between boys and girls and among three skeletal classes. Results: Pubertal growth peak occurred on average four months earlier in girls than boys (p = 0.050. The average duration of pubertal growth peak was 11 months in Class I, seven months in Class II and 17 months in Class III subjects. Interclass differences were highly significant (Cohen's d > 0.08. However, no significant difference was found in the timing of pubertal growth peak onset among three skeletal classes (p = 0.126 in boys, p = 0.262 in girls. Conclusions: Girls enter pubertal growth peak on average four months earlier than boys. Moreover, the duration of pubertal growth peak is on average four months shorter in Class II and six months longer in Class III subjects as compared to Class I subjects.

  8. Peak Operation of Cascaded Hydropower Plants Serving Multiple Provinces

    Directory of Open Access Journals (Sweden)

    Jianjian Shen

    2015-10-01

    Full Text Available The bulk hydropower transmission via trans-provincial and trans-regional power networks in China provides great operational flexibility to dispatch power resources between multiple power grids. This is very beneficial to alleviate the tremendous peak load pressure of most provincial power grids. This study places the focus on peak operations of cascaded hydropower plants serving multiple provinces under a regional connected AC/DC network. The objective is to respond to peak loads of multiple provincial power grids simultaneously. A two-stage search method is developed for this problem. In the first stage, a load reconstruction strategy is proposed to combine multiple load curves of power grids into a total load curve. The purpose is to deal with different load features in load magnitudes, peaks and valleys. A mutative-scale optimization method is then used to determine the generation schedules of hydropower plants. In the second stage, an exterior point search method is established to allocate the generation among multiple receiving power grids. This method produces an initial solution using the load shedding algorithm, and further improves it by iteratively coordinating the generation among different power grids. The proposed method was implemented to the operations of cascaded hydropower plants on Xin-Fu River and another on Hongshui River. The optimization results in two cases satisfied the peak demands of receiving provincial power grids. Moreover, the maximum load difference between peak and valley decreased 12.67% and 11.32% in Shanghai Power Grid (SHPG and Zhejiang Power Grid (ZJPG, exceeding by 4.85% and 6.72% those of the current operational method, respectively. The advantage of the proposed method in alleviating peak-shaving pressure is demonstrated.

  9. Managing peak loads in energy grids: Comparative economic analysis

    International Nuclear Information System (INIS)

    Zhuk, A.; Zeigarnik, Yu.; Buzoverov, E.; Sheindlin, A.

    2016-01-01

    One of the key issues in modern energy technology is managing the imbalance between the generated power and the load, particularly during times of peak demand. The increasing use of renewable energy sources makes this problem even more acute. Various existing technologies, including stationary battery energy storage systems (BESS), can be employed to provide additional power during peak demand times. In the future, integration of on-board batteries of the growing fleet of electric vehicles (EV) and plug-in hybrid electric vehicles (PHEV) into the grid can provide power during peak demand hours (vehicle-to-grid, or V2G technology). This work provides cost estimates of managing peak energy demands using traditional technologies, such as maneuverable power plants, conventional hydroelectric, pumped storage plants and peaker generators, as well as BESS and V2G technologies. The derived estimates provide both per kWh and kW year of energy supplied to the grid. The analysis demonstrates that the use of battery storage is economically justified for short peak demand periods of <1 h. For longer durations, the most suitable technology remains the use of maneuverable steam gas power plants, gas turbine,reciprocating gas engine peaker generators, conventional hydroelectric, pumped storage plants. - Highlights: • Cost of managing peak energy demand employing different technologies are estimated. • Traditional technologies, stationary battery storage and V2G are compared. • Battery storage is economically justified for peak demand periods of <1 h. • V2G appears to have better efficiency than stationary battery storage in low voltage power grids.

  10. Automatic fitting of Gaussian peaks using abductive machine learning

    International Nuclear Information System (INIS)

    Abdel-Aal, R.E.

    1998-01-01

    Analytical techniques have been used for many years for fitting Gaussian peaks in nuclear spectroscopy. However, the complexity of the approach warrants looking for machine-learning alternatives where intensive computations are required only once (during training), while actual analysis on individual spectra is greatly simplified and quickened. This should allow the use of simple portable systems for fast and automated analysis of large numbers of spectra, particularly in situations where accuracy may be traded for speed and simplicity. This paper proposes the use of abductive networks machine learning for this purpose. The Abductory Induction Mechanism (AIM) tool was used to build models for analyzing both single and double Gaussian peaks in the presence of noise depicting statistical uncertainties in collected spectra. AIM networks were synthesized by training on 1,000 representative simulated spectra and evaluated on 500 new spectra. A classifier network determines the multiplicity of single/double peaks with an accuracy of 98%. With statistical uncertainties corresponding to a peak count of 100, average percentage absolute errors for the height, position, and width of single peaks are 4.9, 2.9, and 4.2%, respectively. For double peaks, these average errors are within 7.0, 3.1, and 5.9%, respectively. Models have been developed which account for the effect of a linear background on a single peak. Performance is compared with a neural network application and with an analytical curve-fitting routine, and the new technique is applied to actual data of an alpha spectrum

  11. Analysis of Peak-to-Peak Current Ripple Amplitude in Seven-Phase PWM Voltage Source Inverters

    Directory of Open Access Journals (Sweden)

    Gabriele Grandi

    2013-08-01

    Full Text Available Multiphase systems are nowadays considered for various industrial applications. Numerous pulse width modulation (PWM schemes for multiphase voltage source inverters with sinusoidal outputs have been developed, but no detailed analysis of the impact of these modulation schemes on the output peak-to-peak current ripple amplitude has been reported. Determination of current ripple in multiphase PWM voltage source inverters is important for both design and control purposes. This paper gives the complete analysis of the peak-to-peak current ripple distribution over a fundamental period for multiphase inverters, with particular reference to seven-phase VSIs. In particular, peak-to-peak current ripple amplitude is analytically determined as a function of the modulation index, and a simplified expression to get its maximum value is carried out. Although reference is made to the centered symmetrical PWM, being the most simple and effective solution to maximize the DC bus utilization, leading to a nearly-optimal modulation to minimize the RMS of the current ripple, the analysis can be readily extended to either discontinuous or asymmetrical modulations, both carrier-based and space vector PWM. A similar approach can be usefully applied to any phase number. The analytical developments for all different sub-cases are verified by numerical simulations.

  12. Rotating flow

    CERN Document Server

    Childs, Peter R N

    2010-01-01

    Rotating flow is critically important across a wide range of scientific, engineering and product applications, providing design and modeling capability for diverse products such as jet engines, pumps and vacuum cleaners, as well as geophysical flows. Developed over the course of 20 years' research into rotating fluids and associated heat transfer at the University of Sussex Thermo-Fluid Mechanics Research Centre (TFMRC), Rotating Flow is an indispensable reference and resource for all those working within the gas turbine and rotating machinery industries. Traditional fluid and flow dynamics titles offer the essential background but generally include very sparse coverage of rotating flows-which is where this book comes in. Beginning with an accessible introduction to rotating flow, recognized expert Peter Childs takes you through fundamental equations, vorticity and vortices, rotating disc flow, flow around rotating cylinders and flow in rotating cavities, with an introduction to atmospheric and oceanic circul...

  13. Flow cytogenetics: progress toward chromosomal aberration detection

    International Nuclear Information System (INIS)

    Carrano, A.V.; Gray, J.W.; Van Dilla, M.A.

    1977-01-01

    Using clonal derivatives of the Chinese hamster M3-1 cell line, we demonstrate the potential of flow systems to karyotype homogeneous aberrations (aberrations which are identical and present in every cell) and to detect heterogeneous aberrations (aberrations which occur randomly in a population and are not identical in every cell). Flow cytometry (FCM) of ethidium bromide stained isolated chromosomes from clone 650A of the M3-1 cells distinguishes nine chromosome types from the fourteen present in the actual karyotype. X-irradiation of this parent 650A clone produced two sub-clones with an altered flow karyotype, that is, their FCM distributions were characterized by the addition of new peaks and alterations in area under existing peaks. From the relative DNA content and area for each peak, as determined by computer analysis, we predicted that each clone had undergone a reciprocal translocation involving chromosomes from two peaks. This prediction was confirmed by Giemsa-banding the metaphase cells. Heterogeneous aberrations are reflected in the flow karyotype as an increase in background, that is, an increase in area underlying the chromosome peaks. This increase is dose dependent but, as yet, the sample variability has been too large for quantitative analysis. Flow sorting of the valleys between chromosome peaks produces enriched fractions of aberrant chromosomes for visual analysis. These approaches are potentially applicable to the analysis of chromsomal aberrations induced by environmental contaminants

  14. Directional synthetic aperture flow imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Nikolov, Svetoslav

    2004-01-01

    emissions using a number of defocused elements and a linear frequency modulated pulse (chirp) to improve the signal-to-noise ratio. The received signals are dynamically focused along the flow direction and these signals are used in a cross-correlation estimator for finding the velocity magnitude. The flow...... elements in each emission. A 20 us chirp was used during emission. The RF data were subsequently beamformed off-line and stationary echo canceling was performed. The 60 degrees flow with a peak velocity of 0.15 m/s was determined using 16 groups of 8 emissions and the relative standard deviation was 0...

  15. Measurements of flow-rate transients in one-phase liquid flow

    International Nuclear Information System (INIS)

    Mueller-Roos, J.

    1975-01-01

    A report is given on a method to determine flow-rate transients in a one-phase flow. Periodic temperature signals are superposed on the flow, from which flow times are calculated through correlation each over a half period. The evaluation is carried out according to the digitalization 'off-line' on a large computer. Rate peaks of over 100% within 1.9 s were qualitatively and quantitatively well represented. (orig./LH) [de

  16. Flow visualization

    CERN Document Server

    Merzkirch, Wolfgang

    1974-01-01

    Flow Visualization describes the most widely used methods for visualizing flows. Flow visualization evaluates certain properties of a flow field directly accessible to visual perception. Organized into five chapters, this book first presents the methods that create a visible flow pattern that could be investigated by visual inspection, such as simple dye and density-sensitive visualization methods. It then deals with the application of electron beams and streaming birefringence. Optical methods for compressible flows, hydraulic analogy, and high-speed photography are discussed in other cha

  17. Explanation of the surface peak in charge integrated LEIS spectra

    CERN Document Server

    Draxler, M; Taglauer, E; Schmid, K; Gruber, R; Ermolov, S N; Bauer, P

    2003-01-01

    Low energy ion scattering is very surface sensitive if scattered ions are analyzed. By time-of-flight (TOF) techniques, also neutral and charge integrated spectra (ions plus neutrals) can be obtained, which yield information about deeper layers. In the literature, the observation of a more or less pronounced surface peak was reported for charge integrated spectra, the intensity of the surface peak being higher at low energies and for heavy projectiles. Aiming at a more profound physical understanding of this surface peak, we performed TOF-experiments and computer simulations for He projectiles and a copper target. Experiments were done in the range 1-9 keV for a scattering angle of 129 deg. . The simulation was performed using the MARLOWE code for the given experimental parameters and a polycrystalline target. At low energies, a pronounced surface peak was observed, which fades away at higher energies. This peak is quantitatively reproduced by the simulation, and corresponds to scattering from approx 2 atomic...

  18. PEAK SHIFTS PRODUCED BY CORRELATED RESPONSE TO SELECTION.

    Science.gov (United States)

    Price, Trevor; Turelli, Michael; Slatkin, Montgomery

    1993-02-01

    Traits may evolve both as a consequence of direct selection and also as a correlated response to selection on other traits. While correlated response may be important for both the production of evolutionary novelty and in the build-up of complex characters, its potential role in peak shifts has been neglected empirically and theoretically. We use a quantitative genetic model to investigate the conditions under which a character, Y, which has two alternative optima, can be dragged from one optimum to the other as a correlated response to selection on a second character, X. High genetic correlations between the two characters make the transition, or peak shift, easier, as does weak selection tending to restore Y to the optimum from which it is being dragged. When selection on Y is very weak, the conditions for a peak shift depend only on the location of the new optimum for X and are independent of the strength of selection moving it there. Thus, if the "adaptive valley" for Y is very shallow, little reduction in mean fitness is needed to produce a shift. If the selection acts strongly to keep Y at its current optimum, very intense directional selection on X, associated with a dramatic drop in mean fitness, is required for a peak shift. When strong selection is required, the conditions for peak shifts driven by correlated response might occur rarely, but still with sufficient frequency on a geological timescale to be evolutionarily important. © 1993 The Society for the Study of Evolution.

  19. Pediatric Exercise Testing: Value and Implications of Peak Oxygen Uptake

    Directory of Open Access Journals (Sweden)

    Paolo T. Pianosi

    2017-01-01

    Full Text Available Peak oxygen uptake (peak V ˙ O 2 measured by clinical exercise testing is the benchmark for aerobic fitness. Aerobic fitness, estimated from maximal treadmill exercise, is a predictor of mortality in adults. Peak V ˙ O 2 was shown to predict longevity in patients aged 7–35 years with cystic fibrosis over 25 years ago. A surge of exercise studies in young adults with congenital heart disease over the past decade has revealed significant prognostic information. Three years ago, the first clinical trial in children with pulmonary arterial hypertension used peak V ˙ O 2 as an endpoint that likewise delivered clinically relevant data. Cardiopulmonary exercise testing provides clinicians with biomarkers and clinical outcomes, and researchers with novel insights into fundamental biological mechanisms reflecting an integrated physiological response hidden at rest. Momentum from these pioneering observations in multiple disease states should impel clinicians to employ similar methods in other patient populations; e.g., sickle cell disease. Advances in pediatric exercise science will elucidate new pathways that may identify novel biomarkers. Our initial aim of this essay is to highlight the clinical relevance of exercise testing to determine peak V ˙ O 2 , and thereby convince clinicians of its merit, stimulating future clinical investigators to broaden the application of exercise testing in pediatrics.

  20. Energy Saving by Chopping off Peak Demand Using Day Light

    Directory of Open Access Journals (Sweden)

    Ashok Kumar Maitra

    2011-08-01

    Full Text Available An artificial intelligent technique has been implemented in this research using real time datas to calculate how much energy can be chopped from peak load demand. The results are based on real time data that are taken from power delivering centers. These datas do reflect the present condition of power and a solution to those critical conditions during the peak period. These are done in such a way such that helps in judicious scheduling of load. The time based load scheduling has been done so as to understand the basic criteria for solving power crisis during morning peak and early evening peak. The sunray availability and percentage of load that will use day light saving (DLS technique has been taken into account in this work. The results shows that about 0.5% to 1% of load can be shedded off from the peak load period which otherwise is reduction of power. Thus it otherwise also means that an equivalent amount of energy is saved which amounts to a large saving of national money. This result is obtained on monthly and even daily basis. Thus this paper justifies DLS gives a new renewable technique to save energy.

  1. Enhanced vegetation growth peak and its key mechanisms

    Science.gov (United States)

    Huang, K.; Xia, J.; Wang, Y.; Ahlström, A.; Schwalm, C.; Huntzinger, D. N.; Chen, J.; Cook, R. B.; Fang, Y.; Fisher, J. B.; Jacobson, A. R.; Michalak, A.; Schaefer, K. M.; Wei, Y.; Yan, L.; Luo, Y.

    2017-12-01

    It remains unclear that whether and how the vegetation growth peak has been shifted globally during the past three decades. Here we used two global datasets of gross primary productivity (GPP) and a satellite-derived Normalized Difference Vegetation Index (NDVI) to characterize recent changes in seasonal peak vegetation growth. The attribution of changes in peak growth to their driving factors was examined with several datasets. We demonstrated that the growth peak of global vegetation has been linearly increasing during the past three decades. About 65% of this trend is evenly explained by the expanding croplands (21%), rising atmospheric [CO2] (22%), and intensifying nitrogen deposition (22%). The contribution of expanding croplands to the peak growth trend was substantiated by measurements from eddy-flux towers, sun-induced chlorophyll fluorescence and a global database of plant traits, all of which demonstrated that croplands have a higher photosynthetic capacity than other vegetation types. The contribution of rising atmospheric [CO2] and nitrogen deposition are consistent with the positive response of leaf growth to elevated [CO2] (25%) and nitrogen addition (8%) from 346 manipulated experiments. The positive effect of rising atmospheric [CO2] was also well captured by 15 terrestrial biosphere models. However, most models underestimated the contributions of land-cover change and nitrogen deposition, but overestimated the positive effect of climate change.

  2. Non-Gaussian bias: insights from discrete density peaks

    CERN Document Server

    Desjacques, Vincent; Riotto, Antonio

    2013-01-01

    Corrections induced by primordial non-Gaussianity to the linear halo bias can be computed from a peak-background split or the widespread local bias model. However, numerical simulations clearly support the prediction of the former, in which the non-Gaussian amplitude is proportional to the linear halo bias. To understand better the reasons behind the failure of standard Lagrangian local bias, in which the halo overdensity is a function of the local mass overdensity only, we explore the effect of a primordial bispectrum on the 2-point correlation of discrete density peaks. We show that the effective local bias expansion to peak clustering vastly simplifies the calculation. We generalize this approach to excursion set peaks and demonstrate that the resulting non-Gaussian amplitude, which is a weighted sum of quadratic bias factors, precisely agrees with the peak-background split expectation, which is a logarithmic derivative of the halo mass function with respect to the normalisation amplitude. We point out tha...

  3. Rotational and peak torque stiffness of rugby shoes.

    Science.gov (United States)

    Ballal, Moez S; Usuelli, Federico Giuseppe; Montrasio, Umberto Alfieri; Molloy, Andy; La Barbera, Luigi; Villa, Tomaso; Banfi, Giuseppe

    2014-09-01

    Sports people always strive to avoid injury. Sports shoe designs in many sports have been shown to affect traction and injury rates. The aim of this study is to demonstrate the differing stiffness and torque in rugby boots that are designed for the same effect. Five different types of rugby shoes commonly worn by scrum forwards were laboratory tested for rotational stiffness and peak torque on a natural playing surface generating force patterns that would be consistent with a rugby scrum. The overall internal rotation peak torque was 57.75±6.26 Nm while that of external rotation was 56.55±4.36 Nm. The Peak internal and external rotational stiffness were 0.696±0.1 and 0.708±0.06 Nm/deg respectively. Our results, when compared to rotational stiffness and peak torques of football shoes published in the literature, show that shoes worn by rugby players exert higher rotational and peak torque stiffness compared to football shoes when tested on the same natural surfaces. There was significant difference between the tested rugby shoes brands. In our opinion, to maximize potential performance and lower the potential of non-contact injury, care should be taken in choosing boots with stiffness appropriate to the players main playing role. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. [A new peak detection algorithm of Raman spectra].

    Science.gov (United States)

    Jiang, Cheng-Zhi; Sun, Qiang; Liu, Ying; Liang, Jing-Qiu; An, Yan; Liu, Bing

    2014-01-01

    The authors proposed a new Raman peak recognition method named bi-scale correlation algorithm. The algorithm uses the combination of the correlation coefficient and the local signal-to-noise ratio under two scales to achieve Raman peak identification. We compared the performance of the proposed algorithm with that of the traditional continuous wavelet transform method through MATLAB, and then tested the algorithm with real Raman spectra. The results show that the average time for identifying a Raman spectrum is 0.51 s with the algorithm, while it is 0.71 s with the continuous wavelet transform. When the signal-to-noise ratio of Raman peak is greater than or equal to 6 (modern Raman spectrometers feature an excellent signal-to-noise ratio), the recognition accuracy with the algorithm is higher than 99%, while it is less than 84% with the continuous wavelet transform method. The mean and the standard deviations of the peak position identification error of the algorithm are both less than that of the continuous wavelet transform method. Simulation analysis and experimental verification prove that the new algorithm possesses the following advantages: no needs of human intervention, no needs of de-noising and background removal operation, higher recognition speed and higher recognition accuracy. The proposed algorithm is operable in Raman peak identification.

  5. Variable threshold method for ECG R-peak detection.

    Science.gov (United States)

    Kew, Hsein-Ping; Jeong, Do-Un

    2011-10-01

    In this paper, a wearable belt-type ECG electrode worn around the chest by measuring the real-time ECG is produced in order to minimize the inconvenient in wearing. ECG signal is detected using a potential instrument system. The measured ECG signal is transmits via an ultra low power consumption wireless data communications unit to personal computer using Zigbee-compatible wireless sensor node. ECG signals carry a lot of clinical information for a cardiologist especially the R-peak detection in ECG. R-peak detection generally uses the threshold value which is fixed. There will be errors in peak detection when the baseline changes due to motion artifacts and signal size changes. Preprocessing process which includes differentiation process and Hilbert transform is used as signal preprocessing algorithm. Thereafter, variable threshold method is used to detect the R-peak which is more accurate and efficient than fixed threshold value method. R-peak detection using MIT-BIH databases and Long Term Real-Time ECG is performed in this research in order to evaluate the performance analysis.

  6. Statistical analysis of the low-temperature dislocation peak of internal friction (Bordoni peak) in nanostructured copper

    International Nuclear Information System (INIS)

    Vatazhuk, E.N.; Natsik, V.D.

    2011-01-01

    The temperature-frequency dependence of internal friction in the nanostructured samples of Cu and fibred composite C-32 vol.%Nb with the sizes of structure fragments approx 200 nm is analyzed. Experiments are used as initial information for such analysis. The characteristic for the heavily deformed copper Bordoni peak, located nearby a temperature 90 K, was recorded on temperature dependence of vibration decrement (frequencies 73-350 kHz) in previous experiments. The peak is due to the resonance interaction of sound with the system of thermal activated relaxators, and its width considerably greater in comparison with the width of standard internal friction peak with the single relaxation time. Statistical analysis of the peak is made in terms of assumption that the reason of broadening is random activation energy dispersion of relaxators as a result of intense distortion of copper crystal structure. Good agreement of experimental data and Seeger theory considers thermal activated paired kinks at linear segments of dislocation lines, placed in potential Peierls relief valley, as relaxators of Bordoni peak, was established. It is shown that the registered peak height in experiment correspond to presence at the average one dislocation segment in the interior of crystalline grain with size of 200 nm. Empirical estimates for the critical Peierls stress σp ∼ 2x10 7 Pa and integrated density of the interior grain dislocations ρ d ∼ 10 13 m -2 are made. Nb fibers in the composite Cu-Nb facilitate to formation of nanostructured copper, but do not influence evidently on the Bordoni peak.

  7. An internal friction peak caused by hydrogen in maraging steel

    International Nuclear Information System (INIS)

    Usui, Makoto; Asano, Shigeru

    1996-01-01

    Internal friction in hydrogen-charged iron and steel has so far been studied by a large number of investigators. For pure iron, a well-defined peak of internal friction has been observed under the cold-worked and hydrogen-charged conditions. This is called the hydrogen cold-work peak, or the Snoek-Koester relaxation, which originates from the hydrogen-dislocation interaction. In the present study, a high-strength maraging steel (Fe-18Ni-9Co-5Mo) was chosen as another high-alloy steel which is known to be very susceptible to hydrogen embrittlement. The purpose of this paper is to show a new internal friction peak caused by hydrogen in the maraging steel and to compare it with those found in stainless steels which have so far been studied as typical engineering high-alloy materials

  8. Electron-electron Thomas peak in fast transfer ionization

    International Nuclear Information System (INIS)

    Tolmanov, S. G.; McGuire, J. H.

    2000-01-01

    ''Thomas process'' is a name used for a family of singular two-step processes that can lead to electron transfer. The Thomas process of the ''second kind,'' occurring in reactions with both transfer and ionization, utilizes the e-e scattering in the second step, so this Thomas process requires the dynamics of the electron-electron interaction. We calculate numerically the second order element of an S matrix and corresponding cross sections for the transfer ionization process. We find that the position and shape of the Thomas peak depend on both electron-electron and the electron-nucleus interaction. Also the direct and exchange amplitudes are equal at the peak position. We test the peaking approximation used for transfer ionization. Our results can be compared to experimental results for p + +He→H+He 2+ +e - . (c) 2000 The American Physical Society

  9. Distribution network planning method considering distributed generation for peak cutting

    International Nuclear Information System (INIS)

    Ouyang Wu; Cheng Haozhong; Zhang Xiubin; Yao Liangzhong

    2010-01-01

    Conventional distribution planning method based on peak load brings about large investment, high risk and low utilization efficiency. A distribution network planning method considering distributed generation (DG) for peak cutting is proposed in this paper. The new integrated distribution network planning method with DG implementation aims to minimize the sum of feeder investments, DG investments, energy loss cost and the additional cost of DG for peak cutting. Using the solution techniques combining genetic algorithm (GA) with the heuristic approach, the proposed model determines the optimal planning scheme including the feeder network and the siting and sizing of DG. The strategy for the site and size of DG, which is based on the radial structure characteristics of distribution network, reduces the complexity degree of solving the optimization model and eases the computational burden substantially. Furthermore, the operation schedule of DG at the different load level is also provided.

  10. Correlation Filter Learning Toward Peak Strength for Visual Tracking.

    Science.gov (United States)

    Sui, Yao; Wang, Guanghui; Zhang, Li

    2018-04-01

    This paper presents a novel visual tracking approach to correlation filter learning toward peak strength of correlation response. Previous methods leverage all features of the target and the immediate background to learn a correlation filter. Some features, however, may be distractive to tracking, like those from occlusion and local deformation, resulting in unstable tracking performance. This paper aims at solving this issue and proposes a novel algorithm to learn the correlation filter. The proposed approach, by imposing an elastic net constraint on the filter, can adaptively eliminate those distractive features in the correlation filtering. A new peak strength metric is proposed to measure the discriminative capability of the learned correlation filter. It is demonstrated that the proposed approach effectively strengthens the peak of the correlation response, leading to more discriminative performance than previous methods. Extensive experiments on a challenging visual tracking benchmark demonstrate that the proposed tracker outperforms most state-of-the-art methods.

  11. Gnevyshev peaks in solar radio emissions at different frequencies

    Directory of Open Access Journals (Sweden)

    R. P. Kane

    2009-04-01

    Full Text Available Sunspots have a major 11-year cycle, but the years near the sunspot maximum show two or more peaks called GP (Gnevyshev Peaks. In this communication, it was examined whether these peaks in sunspots are reflected in other parameters such as Lyman-α (the chromospheric emission 121.6 nm, radio emissions 242–15 400 MHz emanating from altitude levels 2000–12 000 km, the low latitude (+45° to −45° solar open magnetic flux and the coronal green line emission (Fe XIV, 530.3 nm. In the different solar cycles 20–23, the similarity extended at least upto the level of 609 MHz, but in cycle 22, the highest level was of 242 MHz. The extension to the higher level in cycle 22 does not seem to be related to the cycle strength Rz(max, or to the cycle length.

  12. Order Tracking Based on Robust Peak Search Instantaneous Frequency Estimation

    International Nuclear Information System (INIS)

    Gao, Y; Guo, Y; Chi, Y L; Qin, S R

    2006-01-01

    Order tracking plays an important role in non-stationary vibration analysis of rotating machinery, especially to run-up or coast down. An instantaneous frequency estimation (IFE) based order tracking of rotating machinery is introduced. In which, a peak search algorithms of spectrogram of time-frequency analysis is employed to obtain IFE of vibrations. An improvement to peak search is proposed, which can avoid strong non-order components or noises disturbing to the peak search work. Compared with traditional methods of order tracking, IFE based order tracking is simplified in application and only software depended. Testing testify the validity of the method. This method is an effective supplement to traditional methods, and the application in condition monitoring and diagnosis of rotating machinery is imaginable

  13. Bayesian Peptide Peak Detection for High Resolution TOF Mass Spectrometry.

    Science.gov (United States)

    Zhang, Jianqiu; Zhou, Xiaobo; Wang, Honghui; Suffredini, Anthony; Zhang, Lin; Huang, Yufei; Wong, Stephen

    2010-11-01

    In this paper, we address the issue of peptide ion peak detection for high resolution time-of-flight (TOF) mass spectrometry (MS) data. A novel Bayesian peptide ion peak detection method is proposed for TOF data with resolution of 10 000-15 000 full width at half-maximum (FWHW). MS spectra exhibit distinct characteristics at this resolution, which are captured in a novel parametric model. Based on the proposed parametric model, a Bayesian peak detection algorithm based on Markov chain Monte Carlo (MCMC) sampling is developed. The proposed algorithm is tested on both simulated and real datasets. The results show a significant improvement in detection performance over a commonly employed method. The results also agree with expert's visual inspection. Moreover, better detection consistency is achieved across MS datasets from patients with identical pathological condition.

  14. The Peak Pairs algorithm for strain mapping from HRTEM images

    Energy Technology Data Exchange (ETDEWEB)

    Galindo, Pedro L. [Departamento de Lenguajes y Sistemas Informaticos, CASEM, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain)], E-mail: pedro.galindo@uca.es; Kret, Slawomir [Institute of Physics, PAS, AL. Lotnikow 32/46, 02-668 Warsaw (Poland); Sanchez, Ana M. [Departamento de Ciencia de los Materiales e Ing. Metalurgica y Q. Inorganica, Facultad de Ciencias, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain); Laval, Jean-Yves [Laboratoire de Physique du Solide, UPR5 CNRS-ESPCI, Paris (France); Yanez, Andres; Pizarro, Joaquin; Guerrero, Elisa [Departamento de Lenguajes y Sistemas Informaticos, CASEM, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain); Ben, Teresa; Molina, Sergio I. [Departamento de Ciencia de los Materiales e Ing. Metalurgica y Q. Inorganica, Facultad de Ciencias, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain)

    2007-11-15

    Strain mapping is defined as a numerical image-processing technique that measures the local shifts of image details around a crystal defect with respect to the ideal, defect-free, positions in the bulk. Algorithms to map elastic strains from high-resolution transmission electron microscopy (HRTEM) images may be classified into two categories: those based on the detection of peaks of intensity in real space and the Geometric Phase approach, calculated in Fourier space. In this paper, we discuss both categories and propose an alternative real space algorithm (Peak Pairs) based on the detection of pairs of intensity maxima in an affine transformed space dependent on the reference area. In spite of the fact that it is a real space approach, the Peak Pairs algorithm exhibits good behaviour at heavily distorted defect cores, e.g. interfaces and dislocations. Quantitative results are reported from experiments to determine local strain in different types of semiconductor heterostructures.

  15. Households' hourly electricity consumption and peak demand in Denmark

    DEFF Research Database (Denmark)

    Møller Andersen, Frits; Baldini, Mattia; Hansen, Lars Gårn

    2017-01-01

    consumption, we analyse the contribution of appliances and new services, such as individual heat pumps and electric vehicles, to peak consumption and the need for demand response incentives to reduce the peak.Initially, the paper presents a new model that represents the hourly electricity consumption profile...... of households in Denmark. The model considers hourly consumption profiles for different household appliances and their contribution to annual household electricity consumption. When applying the model to an official scenario for annual electricity consumption, assuming non-flexible consumption due...... to a considerable introduction of electric vehicles and individual heat pumps, household consumption is expected to increase considerably, especially peak hour consumption is expected to increase.Next the paper presents results from a new experiment where household customers are given economic and/or environmental...

  16. Flow regimes

    International Nuclear Information System (INIS)

    Kh'yuitt, G.

    1980-01-01

    An introduction into the problem of two-phase flows is presented. Flow regimes arizing in two-phase flows are described, and classification of these regimes is given. Structures of vertical and horizontal two-phase flows and a method of their identification using regime maps are considered. The limits of this method application are discussed. The flooding phenomena and phenomena of direction change (flow reversal) of the flow and interrelation of these phenomena as well as transitions from slug regime to churn one and from churn one to annular one in vertical flows are described. Problems of phase transitions and equilibrium are discussed. Flow regimes in tubes where evaporating liquid is running, are described [ru

  17. Total peak shape analysis: detection and quantitation of concurrent fronting, tailing, and their effect on asymmetry measurements.

    Science.gov (United States)

    Wahab, M Farooq; Patel, Darshan C; Armstrong, Daniel W

    2017-08-04

    Most peak shapes obtained in separation science depart from linearity for various reasons such as thermodynamic, kinetic, or flow based effects. An indication of the nature of asymmetry often helps in problem solving e.g. in column overloading, slurry packing, buffer mismatch, and extra-column band broadening. However, existing tests for symmetry/asymmetry only indicate the skewness in excess (tail or front) and not the presence of both. Two simple graphical approaches are presented to analyze peak shapes typically observed in gas, liquid, and supercritical fluid chromatography as well as capillary electrophoresis. The derivative test relies on the symmetry of the inflection points and the maximum and minimum values of the derivative. The Gaussian test is a constrained curve fitting approach and determines the residuals. The residual pattern graphically allows the user to assess the problematic regions in a given peak, e.g., concurrent tailing or fronting, something which cannot be easily done with other current methods. The template provided in MS Excel automates this process. The total peak shape analysis extracts the peak parameters from the upper sections (>80% height) of the peak rather than the half height as is done conventionally. A number of situations are presented and the utility of this approach in solving practical problems is demonstrated. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Study of peak broadening effect in floor time histories

    International Nuclear Information System (INIS)

    Soni, R.S.; Kushwaha, H.S.; Mahajan, S.C.; Kakodkar, A.

    1996-01-01

    Seismic design of secondary systems such components and piping is usually carried out by using the floor motions at their support points. These floor motions can be in the form of Floor Response Spectra (FRS) or the Floor Time Histories (FTH). In order to account for the various uncertainties in generating these floor motions, these motions should be peak broadened and smoothened as per the regulatory codes. Presented here in this paper is the methodology to account for such peak broadening effect in the FTH. Results of this study have been compared with the FRS approach and various important conclusions have been arrived at based on the study

  19. CO2 emissions: a peak level in 2010

    International Nuclear Information System (INIS)

    Anon.

    2011-01-01

    After a reduction of CO 2 emissions in 2009 due to the financial crisis, these emissions have again reached a peak in 2010: 30.6 Gt, it means an increase by 5% compared to the previous peak. According to IEA (International Energy Agency): 44% of the emissions come from coal, 36% from oil and 20% from natural gas, and OECD countries are responsible of 40% of the CO 2 global emissions but only of 25% of their increase since 2009. For China and India the emissions of CO 2 have increased sharply due to their strong economic growth. (A.C.)

  20. Peak Oil and the Everyday Complexity of Human Progress Narratives

    Directory of Open Access Journals (Sweden)

    John C. Pruit

    2012-11-01

    Full Text Available The “big” story of human progress has polarizing tendencies featuring the binary options of progress or decline. I consider human progress narratives in the context of everyday life. Analysis of the “little” stories from two narrative environments focusing on peak oil offers a more complex picture of the meaning and contours of the narrative. I consider the impact of differential blog site commitments to peak oil perspectives and identify five narrative types culled from two narrative dimensions. I argue that the lived experience complicates human progress narratives, which is no longer an either/or proposition.

  1. National energy peak leveling program (NEPLP). Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    This multisectioned three-Volume report is responsive to the requirements of Contract E (04-3)-1152 to provide a detailed methodology, to include management, technology, and socio-economic aspects, of a voluntary community program of computer-assisted peak load leveling and energy conservation in commercial community facilities. The demonstration project established proof-of-concept in reducing the kW-demand peak by the unofficial goal of 10%, with concurrent kWh savings. This section of volume III contains appendixes of information on load shedding determination, analysis, socio-economic study, contractual cross references, and definitions.

  2. Prediction of a Photon Peak in Heavy Ion Collisions

    Energy Technology Data Exchange (ETDEWEB)

    Casalderrey-Solana, Jorge; Mateos, David

    2008-07-01

    We show that if a flavour-less vector meson remains bound after deconfinement, and if its limiting velocity in the quark-gluon plasma is subluminal, then this meson produces a distinct peak in the spectrum of thermal photons emitted by the plasma. We also demonstrate that this effect is a universal property of all strongly coupled, large-Nc plasmas with a gravity dual. For the J/psi the corresponding peak lies between 3 and 5 GeV and could be observed at LHC.

  3. National energy peak leveling program (NEPLP). Final report

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-12-01

    This three-volume report is responsive to the requirements of contract E (04-3)-1152 to provide a detailed methodology, to include management, technology, and socio-economic aspects, of a voluntary community program for computer-assisted peak load leveling and energy conservation in commercial community facilities. The demonstration project established proof-of-concept in reducing the kW-demand peak by the unofficial goal of 10%, with concurrent kWh savings. The report consists of the following three volumes: Volume I: management overview; Volume II: methodology and technology; and Volume III; appendices.

  4. High-Average, High-Peak Current Injector Design

    CERN Document Server

    Biedron, S G; Virgo, M

    2005-01-01

    There is increasing interest in high-average-power (>100 kW), um-range FELs. These machines require high peak current (~1 kA), modest transverse emittance, and beam energies of ~100 MeV. High average currents (~1 A) place additional constraints on the design of the injector. We present a design for an injector intended to produce the required peak currents at the injector, eliminating the need for magnetic compression within the linac. This reduces the potential for beam quality degradation due to CSR and space charge effects within magnetic chicanes.

  5. Demand Side Management: An approach to peak load smoothing

    Science.gov (United States)

    Gupta, Prachi

    A preliminary national-level analysis was conducted to determine whether Demand Side Management (DSM) programs introduced by electric utilities since 1992 have made any progress towards their stated goal of reducing peak load demand. Estimates implied that DSM has a very small effect on peak load reduction and there is substantial regional and end-user variability. A limited scholarly literature on DSM also provides evidence in support of a positive effect of demand response programs. Yet, none of these studies examine the question of how DSM affects peak load at the micro-level by influencing end-users' response to prices. After nearly three decades of experience with DSM, controversy remains over how effective these programs have been. This dissertation considers regional analyses that explore both demand-side solutions and supply-side interventions. On the demand side, models are estimated to provide in-depth evidence of end-user consumption patterns for each North American Electric Reliability Corporation (NERC) region, helping to identify sectors in regions that have made a substantial contribution to peak load reduction. The empirical evidence supports the initial hypothesis that there is substantial regional and end-user variability of reductions in peak demand. These results are quite robust in rapidly-urbanizing regions, where air conditioning and lighting load is substantially higher, and regions where the summer peak is more pronounced than the winter peak. It is also evident from the regional experiences that active government involvement, as shaped by state regulations in the last few years, has been successful in promoting DSM programs, and perhaps for the same reason we witness an uptick in peak load reductions in the years 2008 and 2009. On the supply side, we estimate the effectiveness of DSM programs by analyzing the growth of capacity margin with the introduction of DSM programs. The results indicate that DSM has been successful in offsetting the

  6. Universal parametric correlations of conductance peaks in quantum dots

    International Nuclear Information System (INIS)

    Alhassid, Y.; Attias, H.

    1996-01-01

    We compute the parametric correlation function of the conductance peaks in chaotic and weakly disordered quantum dots in the Coulomb blockade regime and demonstrate its universality upon an appropriate scaling of the parameter. For a symmetric dot we show that this correlation function is affected by breaking time-reversal symmetry but is independent of the details of the channels in the external leads. We derive a new scaling which depends on the eigenfunctions alone and can be extracted directly from the conductance peak heights. Our results are in excellent agreement with model simulations of a disordered quantum dot. copyright 1996 The American Physical Society

  7. Detection of Golden apples' climacteric peak by laser biospeckle measurements.

    Science.gov (United States)

    Nassif, Rana; Nader, Christelle Abou; Afif, Charbel; Pellen, Fabrice; Le Brun, Guy; Le Jeune, Bernard; Abboud, Marie

    2014-12-10

    In this paper, we report a study in which a laser biospeckle technique is used to detect the climacteric peak indicating the optimal ripeness of fruits. We monitor two batches of harvested Golden apples going through the ripening phase in low- and room-temperature environments, determine speckle parameters, and measure the emitted ethylene concentration using gas chromatography as reference method. Speckle results are then correlated to the emitted ethylene concentration by a principal component analysis. From a practical point of view, this approach allows us to validate biospeckle as a noninvasive and alternative method to respiration rate and ethylene production for climacteric peak detection as a ripening index.

  8. Rapid flow imaging method

    International Nuclear Information System (INIS)

    Pelc, N.J.; Spritzer, C.E.; Lee, J.N.

    1988-01-01

    A rapid, phase-contrast, MR imaging method of imaging flow has been implemented. The method, called VIGRE (velocity imaging with gradient recalled echoes), consists of two interleaved, narrow flip angle, gradient-recalled acquisitions. One is flow compensated while the second has a specified flow encoding (both peak velocity and direction) that causes signals to contain additional phase in proportion to velocity in the specified direction. Complex image data from the first acquisition are used as a phase reference for the second, yielding immunity from phase accumulation due to causes other than motion. Images with pixel values equal to MΔΘ where M is the magnitude of the flow compensated image and ΔΘ is the phase difference at the pixel, are produced. The magnitude weighting provides additional vessel contrast, suppresses background noise, maintains the flow direction information, and still allows quantitative data to be retrieved. The method has been validated with phantoms and is undergoing initial clinical evaluation. Early results are extremely encouraging

  9. Gas Flow Detection System

    Science.gov (United States)

    Moss, Thomas; Ihlefeld, Curtis; Slack, Barry

    2010-01-01

    thermal equilibrium with the test flow of GN2. The temperature drop of each branch from its "no flow" stable temperature peak to its stable "with flow" temperature will allow the operator to determine whether a minimum level of flow exists. An alternative operation has the operator turning on the software only long enough to record the ambient temperature of the tubing before turning on the heaters and initiating GN2 flow. The stable temperature of the heated tubing with GN2 flow is then compared with the ambient tubing temperature to determine if flow is present in each branch. To help quantify the level of flow in the manifolds, each branch will be bench calibrated to establish its thermal properties using the flow detection system and different flow rates. These calibration values can then be incorporated into the software application to provide more detailed flow rate information.

  10. American video peak store gives fuel a better image

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    A new American image enhancement system using a video peak frame store aims to overcome the common problems of viewing serial numbers on irradiated fuel assemblies within the reactor core whilst reducing operator exposure at the same time. Other nuclear plant inspection applications are envisaged. (author)

  11. Detection of Mg spinel lithologies on central peak of crater ...

    Indian Academy of Sciences (India)

    identified Fe bearing Mg-spinel-rich rock types are defined by their strong 2-μm ... The Modified Gaussian Modeling (MGM) analysis ... study the deep crustal and/or upper mantle composition and may lead to a fresh ... Lunar surface; Mg-spinel; central peak; Theophilus; remote sensing. .... The explanation of these spec-.

  12. High precision 16K, 16 channel peak sensing CAMAC ADC

    International Nuclear Information System (INIS)

    Jain, Mamta; Subramaniam, E.T

    2013-01-01

    A high density, peak sensing, analog to digital converter (ADC) double width module with CAMAC back plane has been developed for nuclear physics experiments with a large number of detectors. This module has sixteen independent channels in plug-in daughter card mother board mode

  13. Standardization of I-125. Sum-Peak Coincidence Counting

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    2011-01-01

    I-125 is a nuclide which presents difficulties for standardization. The sum-peak method is one of the procedures used to standardize this radionuclide. Initially NaI (Tl)detectors and then the semiconductor detectors with higher resolution have been used.This paper describes the different methods based on the sum-peak procedure and the different expressions used to calculate the activity are deduced. We describe a general procedure for obtaining all of the above equations and many more. We analyze the influence of uncertainties in the used parameters in the uncertainty of the activity. We give a complete example of the transmission of uncertainty and the effects of correlations in the uncertainty of the activity of the sample. High-resolution spectra show an unresolved doublet of 62.0 keV and 62.8 keV. The paper presents two approaches to solve this problem. One is based on the calculation of area ratio and the sum of peak areas obtained from atomic and nuclear data, in the other we modify the equations so that the sum of the peak areas doublet, rather than its components, is present. (Author) 19 refs.

  14. Focal F0 peak shape and sentence mode in Swedish

    DEFF Research Database (Denmark)

    Ambrazaitis, Gilbert; Buanzur, Tuarik C.; Niebuhr, Oliver

    2015-01-01

    Shape characteristics of rising-falling accentual F0 peaks of Stockholm Swedish Accent I words in narrow focus are studied in a corpus of 287 read sentences. The corpus includes statements and three types of polar questions. Results reveal a clear effect of sentence mode on the shape of the accen...

  15. Size-independent peak shift between normal and upconversion ...

    Indian Academy of Sciences (India)

    2014-02-12

    Feb 12, 2014 ... In this article, we report size-dependent measurement of the shift in peak of upconversion photoluminescence spectra compared to that of normal photoluminescence using a 800 nm femtosecond laser and its second harmonic. It has been shown that the upconversion photoluminescence is always ...

  16. Scheduling Non-Preemptible Jobs to Minimize Peak Demand

    Directory of Open Access Journals (Sweden)

    Sean Yaw

    2017-10-01

    Full Text Available This paper examines an important problem in smart grid energy scheduling; peaks in power demand are proportionally more expensive to generate and provision for. The issue is exacerbated in local microgrids that do not benefit from the aggregate smoothing experienced by large grids. Demand-side scheduling can reduce these peaks by taking advantage of the fact that there is often flexibility in job start times. We focus attention on the case where the jobs are non-preemptible, meaning once started, they run to completion. The associated optimization problem is called the peak demand minimization problem, and has been previously shown to be NP-hard. Our results include an optimal fixed-parameter tractable algorithm, a polynomial-time approximation algorithm, as well as an effective heuristic that can also be used in an online setting of the problem. Simulation results show that these methods can reduce peak demand by up to 50% versus on-demand scheduling for household power jobs.

  17. Bragg peak and relative biological efficiency of different ions

    Czech Academy of Sciences Publication Activity Database

    Lokajíček st., Miloš; Judas, Libor; Kundrát, Pavel

    2002-01-01

    Roč. 64, Suppl. 1 (2002), S309-S309 ISSN 0167-8140 R&D Projects: GA AV ČR(CZ) KSK4055109 Keywords : Bragg peak * relative biological efficisncy * radiological mechanism Subject RIV: CC - Organic Chemistry Impact factor: 2.838, year: 2002

  18. Measurement of peak temperature along an optical fiber

    International Nuclear Information System (INIS)

    Fox, R.J.

    1983-01-01

    A multimode silica-clad optical fiber with a liquid silicone core was used as a distributed-line peak-temperature sensor over a temperature range from ambient to 190 0 C. The maximum error was 2 0 C and was essentially independent of the length or position of the hot zone

  19. Biomechanical aspects of peak performance in human swimming

    NARCIS (Netherlands)

    Toussaint, H.M.; Truijens, M.J.

    2005-01-01

    Peak performances in sport require the full deployment of all the powers an athlete possesses. How factors such as mechanical power output, technique and drag, each individually, but also in concert, determine swimming performance is the subject of this enquiry. This overview of swimming

  20. T(peak)T(end) interval in long QT syndrome

    DEFF Research Database (Denmark)

    Kanters, Jørgen Kim; Haarmark, Christian; Vedel-Larsen, Esben

    2008-01-01

    BACKGROUND: The T(peak)T(end) (T(p)T(e)) interval is believed to reflect the transmural dispersion of repolarization. Accordingly, it should be a risk factor in long QT syndrome (LQTS). The aim of the study was to determine the effect of genotype on T(p)T(e) interval and test whether it was relat...

  1. Peak Communication Experiences: Concept, Structure, and Sex Differences.

    Science.gov (United States)

    Gordon, Ron; Dulaney, Earl

    A study was conducted to test a "peak communication experience" (PCE) scale developed from Abraham Maslow's theory of PCE's, a model of one's highest interpersonal communication moments in terms of perceived mutual understanding, happiness, and personal fulfillment. Nineteen items, extrapolated from Maslow's model but rendered more…

  2. Analysis of multibeam-hydrosweep echo peaks for seabed characterisation

    Digital Repository Service at National Institute of Oceanography (India)

    Chakraborty, B.; Schenke, H.W.; Kodagali, V.N.; Hagen, R.

    , in general, Gaussian in nature except in the case of the Kainan Maru seamount summit (area D). The outer beams of the Enderby abyssal plain (area C) echo-peak PDF statistics reveal the highest possible large-scale feature dominance. Interestingly, Extremal...

  3. Characteristics of peaks of inhalation exposure to organic solvents

    NARCIS (Netherlands)

    Preller, L.; Burstyn, I.; Pater, N. de; Kromhout, H.

    2004-01-01

    Objectives: To determine which exposure metrics are sufficient to characterize 'peak' inhalation exposure to organic solvents (OS) during spraying operations. Methods: Personal exposure measurements (n = 27; duration 5-159 min) were collected during application of paints, primers, resins and glues

  4. A new sample of faint Gigahertz Peaked Spectrum radio sources

    NARCIS (Netherlands)

    Snellen, IAG; Schilizzi, RT; de Bruyn, AG; Miley, GK; Rengelink, RB; Rottgering, HJ

    The Westerbork Northern Sky Survey (WENSS) has been used to select a sample of Gigahertz Peaked Spectrum (GPS) radio sources at flux densities one to two orders of magnitude lower than bright GPS sources investigated in earlier studies. Sources with inverted spectra at frequencies above 325 MHz have

  5. Efficient protection of mercury peaks; Effizienter Schutz vor Quecksilberspitzen

    Energy Technology Data Exchange (ETDEWEB)

    Esser-Schmittmann, Wolfgang; Schmitz, Simone [Carbon Service und Consulting GmbH und Co. KG, Vettweiss (Germany)

    2010-07-15

    Exhaust gases from the combustion of wastes and substitute fuels temporarily exhibit again and again emission peaks of mercury which in individual cases cannot be caught by the exhaust after-treatment system designed for the stationary plant operation. The problem can be solved inexpensively by dosage of small quantities of chemisorptive powder activated charcoal.

  6. Analytical construction of peaked solutions for the nonlinear ...

    African Journals Online (AJOL)

    These results demonstrate the existence of peaked pulses propagating through a pair plasma. The algebraic decay rate of the pulses are determined analytically, as well. The method discussed here can be applied to approximate solutions to similar nonlinear partial differential equations of nonlinear Schrödinger type.

  7. A 62GHz inductor-peaked rectifier with 7% efficiency

    NARCIS (Netherlands)

    Gao, H.; Matters - Kammerer, M.; Milosevic, D.; Roermund, van A.H.M.; Baltus, P.G.M.

    2013-01-01

    This paper presents the first 62 GHz fully onchip RF-DC rectifier in 65nm CMOS technology. The rectifier is the bottleneck in realizing on-chip wireless power receivers. In this paper, efficiency problems of the mm-wave rectifier are discussed and the inductor-peaked rectifier structure is proposed

  8. Peak metamorphic temperatures from cation diffusion zoning in garnet

    DEFF Research Database (Denmark)

    Smit, Matthijs Arjen; Scherer, Erik; Mezger, Klaus

    2013-01-01

    ) to develop a tool that uses the diffusion zoning of these cations in garnet to constrain peak temperature conditions for garnet-bearing rocks. The thermometric approach was externally tested by applying it to garnet crystals from various metamorphic terranes worldwide and comparing the results to published...

  9. Measurement of peak discharge at dams by indirect methods

    Science.gov (United States)

    Hulsing, Harry

    1967-01-01

    This chapter describes procedures for measuring peak discharges using dams, weirs, and embankments. Field and office procedures limited to this method are described. Discharge coefficients and formulas are given for three general classes of weirs-sharp-crested, broad-crested, and round-crested-and for highway embankments and weirs of unusual shape. The effects of submergence are defined for most forms.

  10. Comparative LC-MS: A landscape of Peaks and Valleys

    NARCIS (Netherlands)

    America, A.H.P.; Cordewener, J.H.G.

    2008-01-01

    Quantitative proteomics approaches using stable isotopes are well-known and used in many labs nowadays. More recently, high resolution quantitative approaches are reported that rely on LC-MS quantitation of peptide concentrations by comparing peak intensities between multiple runs obtained by

  11. Robust peak-shaving for a neighborhood with electric vehicles

    NARCIS (Netherlands)

    Gerards, Marco Egbertus Theodorus; Hurink, Johann L.

    2016-01-01

    Demand Side Management (DSM) is a popular approach for grid-aware peak-shaving. The most commonly used DSM methods either have no look ahead feature and risk deploying flexibility too early, or they plan ahead using predictions, which are in general not very reliable. To counter this, a DSM approach

  12. Climate Change Impacts on Peak Electricity Consumption: US vs. Europe.

    Science.gov (United States)

    Auffhammer, M.

    2016-12-01

    It has been suggested that climate change impacts on the electric sector will account for the majority of global economic damages by the end of the current century and beyond. This finding is at odds with the relatively modest increase in climate driven impacts on consumption. Comprehensive high frequency load balancing authority level data have not been used previously to parameterize the relationship between electric demand and temperature for any major economy. Using statistical models we analyze multi-year data from load balancing authorities in the United States of America and the European Union, which are responsible for more than 90% of the electricity delivered to residential, industrial, commercial and agricultural customers. We couple the estimated response functions between total daily consumption and daily peak load with an ensemble of downscaled GCMs from the CMIP5 archive to simulate climate change driven impacts on both outcomes. We show moderate and highly spatially heterogeneous changes in consumption. The results of our peak load simulations, however, suggest significant changes in the intensity and frequency of peak events throughout the United States and Europe. As the electricity grid is built to endure maximum load, which usually occurs on the hottest day of the year, our findings have significant implications for the construction of costly peak generating and transmission capacity.

  13. quasi hyperrigidity and weak peak points for non-commutative ...

    Indian Academy of Sciences (India)

    7

    Abstract. In this article, we introduce the notions of weak boundary repre- sentation, quasi hyperrigidity and weak peak points in the non-commutative setting for operator systems in C∗-algebras. An analogue of Saskin's theorem relating quasi hyperrigidity and weak Choquet boundary for particular classes of C∗-algebras is ...

  14. Simple area determination of strongly overlapping ion mobility peaks

    Czech Academy of Sciences Publication Activity Database

    Borovcová, L.; Hermannová, M.; Pauk, V.; Šimek, M.; Havlíček, Vladimír; Lemr, Karel

    2017-01-01

    Roč. 981, AUG 15 (2017), s. 71-79 ISSN 0003-2670 Grant - others:GA MŠk(CZ) LO1305 Institutional support: RVO:61388971 Keywords : Ion mobility-mass spectrometry * Fitting of mobility peaks * Analysis of isomers Subject RIV: CB - Analytical Chemistry, Separation OBOR OECD: Analytical chemistry Impact factor: 4.950, year: 2016

  15. Standardization of I-125. Sum-Peak Coincidence Counting

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    2011-07-01

    I-125 is a nuclide which presents difficulties for standardization. The sum-peak method is one of the procedures used to standardize this radionuclide. Initially NaI (Tl)detectors and then the semiconductor detectors with higher resolution have been used.This paper describes the different methods based on the sum-peak procedure and the different expressions used to calculate the activity are deduced. We describe a general procedure for obtaining all of the above equations and many more. We analyze the influence of uncertainties in the used parameters in the uncertainty of the activity. We give a complete example of the transmission of uncertainty and the effects of correlations in the uncertainty of the activity of the sample. High-resolution spectra show an unresolved doublet of 62.0 keV and 62.8 keV. The paper presents two approaches to solve this problem. One is based on the calculation of area ratio and the sum of peak areas obtained from atomic and nuclear data, in the other we modify the equations so that the sum of the peak areas doublet, rather than its components, is present. (Author) 19 refs.

  16. Automatic Locking of Laser Frequency to an Absorption Peak

    Science.gov (United States)

    Koch, Grady J.

    2006-01-01

    An electronic system adjusts the frequency of a tunable laser, eventually locking the frequency to a peak in the optical absorption spectrum of a gas (or of a Fabry-Perot cavity that has an absorption peak like that of a gas). This system was developed to enable precise locking of the frequency of a laser used in differential absorption LIDAR measurements of trace atmospheric gases. This system also has great commercial potential as a prototype of means for precise control of frequencies of lasers in future dense wavelength-division-multiplexing optical communications systems. The operation of this system is completely automatic: Unlike in the operation of some prior laser-frequency-locking systems, there is ordinarily no need for a human operator to adjust the frequency manually to an initial value close enough to the peak to enable automatic locking to take over. Instead, this system also automatically performs the initial adjustment. The system (see Figure 1) is based on a concept of (1) initially modulating the laser frequency to sweep it through a spectral range that includes the desired absorption peak, (2) determining the derivative of the absorption peak with respect to the laser frequency for use as an error signal, (3) identifying the desired frequency [at the very top (which is also the middle) of the peak] as the frequency where the derivative goes to zero, and (4) thereafter keeping the frequency within a locking range and adjusting the frequency as needed to keep the derivative (the error signal) as close as possible to zero. More specifically, the system utilizes the fact that in addition to a zero crossing at the top of the absorption peak, the error signal also closely approximates a straight line in the vicinity of the zero crossing (see Figure 2). This vicinity is the locking range because the linearity of the error signal in this range makes it useful as a source of feedback for a proportional + integral + derivative control scheme that

  17. Reducing electricity demand peaks by scheduling home appliances usage

    Energy Technology Data Exchange (ETDEWEB)

    Rossello-Busquet, A.; Kardaras, G.; Baek Iversen, V.; Soler, J.; Dittmann, L.

    2011-05-15

    Nowadays there is a tendency to consume electricity during the same period of the day leading to demand peaks. Regular energy consumption habits lead to demand peaks at specific temporal intervals, because users consume power at the same time. In order to avoid demand peaks, users' appliances should consume electricity in a more temporarily distributed way. A new methodology to schedule the usage of home appliances is proposed and analyzed in this paper. The main concept behind this approach is the aggregation of home appliances into priority classes and the definition of a maximum power consumption limit, which is not allowed to be exceeded during peak hours. The scenario simulated describes a modern household, where the electrical devices are classified in low and high priority groups. The high priority devices are always granted power in order to operate without temporal restrictions. On the contrary, the low priority devices have to pause their operation, when the algorithm dictates it, and resume it in the future. This can become beneficial for both energy companies and users. The electricity suppliers companies will be capable of regulating power generation during demand peaks periods. Moreover, users can be granted lower electricity bill rates for accepting delaying the operation of some of their appliances. In order to analyze this scenario, teletraffic engineering theory, which is used in evaluating the performance of telecommunication networks, is used. A reversible fair scheduling (RFS) algorithm, which was originally developed for telecommunication networks, is applied. The purpose is to analyze how a power consumption limit and priorities for home appliances will affect the demand peak and the users' everyday life. Verification of the effectiveness of the RFS algorithm is done by means of simulation and by using real data for power consumption and operation hours. The defined maximum power limit of 750 and 1000 Watt was not exceeded during

  18. Peak Dose Assessment for Proposed DOE-PPPO Authorized Limits

    International Nuclear Information System (INIS)

    Maldonado, Delis

    2012-01-01

    The Oak Ridge Institute for Science and Education (ORISE), a U.S. Department of Energy (DOE) prime contractor, was contracted by the DOE Portsmouth/Paducah Project Office (DOE-PPPO) to conduct a peak dose assessment in support of the Authorized Limits Request for Solid Waste Disposal at Landfill C-746-U at the Paducah Gaseous Diffusion Plant (DOE-PPPO 2011a). The peak doses were calculated based on the DOE-PPPO Proposed Single Radionuclides Soil Guidelines and the DOE-PPPO Proposed Authorized Limits (AL) Volumetric Concentrations available in DOE-PPPO 2011a. This work is provided as an appendix to the Dose Modeling Evaluations and Technical Support Document for the Authorized Limits Request for the C-746-U Landfill at the Paducah Gaseous Diffusion Plant, Paducah, Kentucky (ORISE 2012). The receptors evaluated in ORISE 2012 were selected by the DOE-PPPO for the additional peak dose evaluations. These receptors included a Landfill Worker, Trespasser, Resident Farmer (onsite), Resident Gardener, Recreational User, Outdoor Worker and an Offsite Resident Farmer. The RESRAD (Version 6.5) and RESRAD-OFFSITE (Version 2.5) computer codes were used for the peak dose assessments. Deterministic peak dose assessments were performed for all the receptors and a probabilistic dose assessment was performed only for the Offsite Resident Farmer at the request of the DOE-PPPO. In a deterministic analysis, a single input value results in a single output value. In other words, a deterministic analysis uses single parameter values for every variable in the code. By contrast, a probabilistic approach assigns parameter ranges to certain variables, and the code randomly selects the values for each variable from the parameter range each time it calculates the dose (NRC 2006). The receptor scenarios, computer codes and parameter input files were previously used in ORISE 2012. A few modifications were made to the parameter input files as appropriate for this effort. Some of these changes

  19. Forecasting Strategies for Predicting Peak Electric Load Days

    Science.gov (United States)

    Saxena, Harshit

    Academic institutions spend thousands of dollars every month on their electric power consumption. Some of these institutions follow a demand charges pricing structure; here the amount a customer pays to the utility is decided based on the total energy consumed during the month, with an additional charge based on the highest average power load required by the customer over a moving window of time as decided by the utility. Therefore, it is crucial for these institutions to minimize the time periods where a high amount of electric load is demanded over a short duration of time. In order to reduce the peak loads and have more uniform energy consumption, it is imperative to predict when these peaks occur, so that appropriate mitigation strategies can be developed. The research work presented in this thesis has been conducted for Rochester Institute of Technology (RIT), where the demand charges are decided based on a 15 minute sliding window panned over the entire month. This case study makes use of different statistical and machine learning algorithms to develop a forecasting strategy for predicting the peak electric load days of the month. The proposed strategy was tested for a whole year starting May 2015 to April 2016 during which a total of 57 peak days were observed. The model predicted a total of 74 peak days during this period, 40 of these cases were true positives, hence achieving an accuracy level of 70 percent. The results obtained with the proposed forecasting strategy are promising and demonstrate an annual savings potential worth about $80,000 for a single submeter of RIT.

  20. Peak Running Intensity of International Rugby: Implications for Training Prescription.

    Science.gov (United States)

    Delaney, Jace A; Thornton, Heidi R; Pryor, John F; Stewart, Andrew M; Dascombe, Ben J; Duthie, Grant M

    2017-09-01

    To quantify the duration and position-specific peak running intensities of international rugby union for the prescription and monitoring of specific training methodologies. Global positioning systems (GPS) were used to assess the activity profile of 67 elite-level rugby union players from 2 nations across 33 international matches. A moving-average approach was used to identify the peak relative distance (m/min), average acceleration/deceleration (AveAcc; m/s 2 ), and average metabolic power (P met ) for a range of durations (1-10 min). Differences between positions and durations were described using a magnitude-based network. Peak running intensity increased as the length of the moving average decreased. There were likely small to moderate increases in relative distance and AveAcc for outside backs, halfbacks, and loose forwards compared with the tight 5 group across all moving-average durations (effect size [ES] = 0.27-1.00). P met demands were at least likely greater for outside backs and halfbacks than for the tight 5 (ES = 0.86-0.99). Halfbacks demonstrated the greatest relative distance and P met outputs but were similar to outside backs and loose forwards in AveAcc demands. The current study has presented a framework to describe the peak running intensities achieved during international rugby competition by position, which are considerably higher than previously reported whole-period averages. These data provide further knowledge of the peak activity profiles of international rugby competition, and this information can be used to assist coaches and practitioners in adequately preparing athletes for the most demanding periods of play.

  1. Peak-locking reduction for particle image velocimetry

    International Nuclear Information System (INIS)

    Michaelis, Dirk; Wieneke, Bernhard; Neal, Douglas R

    2016-01-01

    A parametric study of the factors contributing to peak-locking, a known bias error source in particle image velocimetry (PIV), is conducted using synthetic data that are processed with a state-of-the-art PIV algorithm. The investigated parameters include: particle image diameter, image interpolation techniques, the effect of asymmetric versus symmetric window deformation, number of passes and the interrogation window size. Some of these parameters are found to have a profound effect on the magnitude of the peak-locking error. The effects for specific PIV cameras are also studied experimentally using a precision turntable to generate a known rotating velocity field. Image time series recorded using this experiment show a linear range of pixel and sub-pixel shifts ranging from 0 to  ±4 pixels. Deviations in the constant vorticity field (ω z ) reveal how peak-locking can be affected systematically both by varying parameters of the detection system such as the focal distance and f -number, and also by varying the settings of the PIV analysis. A new a priori technique for reducing the bias errors associated with peak-locking in PIV is introduced using an optical diffuser to avoid undersampled particle images during the recording of the raw images. This technique is evaluated against other a priori approaches using experimental data and is shown to perform favorably. Finally, a new a posteriori anti peak-locking filter (APLF) is developed and investigated, which shows promising results for both synthetic data and real measurements for very small particle image sizes. (paper)

  2. Estimation of uncertainty bounds for individual particle image velocimetry measurements from cross-correlation peak ratio

    International Nuclear Information System (INIS)

    Charonko, John J; Vlachos, Pavlos P

    2013-01-01

    Numerous studies have established firmly that particle image velocimetry (PIV) is a robust method for non-invasive, quantitative measurements of fluid velocity, and that when carefully conducted, typical measurements can accurately detect displacements in digital images with a resolution well below a single pixel (in some cases well below a hundredth of a pixel). However, to date, these estimates have only been able to provide guidance on the expected error for an average measurement under specific image quality and flow conditions. This paper demonstrates a new method for estimating the uncertainty bounds to within a given confidence interval for a specific, individual measurement. Here, cross-correlation peak ratio, the ratio of primary to secondary peak height, is shown to correlate strongly with the range of observed error values for a given measurement, regardless of flow condition or image quality. This relationship is significantly stronger for phase-only generalized cross-correlation PIV processing, while the standard correlation approach showed weaker performance. Using an analytical model of the relationship derived from synthetic data sets, the uncertainty bounds at a 95% confidence interval are then computed for several artificial and experimental flow fields, and the resulting errors are shown to match closely to the predicted uncertainties. While this method stops short of being able to predict the true error for a given measurement, knowledge of the uncertainty level for a PIV experiment should provide great benefits when applying the results of PIV analysis to engineering design studies and computational fluid dynamics validation efforts. Moreover, this approach is exceptionally simple to implement and requires negligible additional computational cost. (paper)

  3. Revisiting the Correlations of Peak Luminosity with Spectral Lag and Peak Energy of the Observed Gamma-ray Bursts

    Directory of Open Access Journals (Sweden)

    Yun-A Jo

    2016-12-01

    Full Text Available An analysis of light curves and spectra of observed gamma-ray bursts in gamma-ray ranges is frequently demanded because the prompt emission contains immediate details regarding the central engine of gamma-ray bursts (GRBs. We have revisited the relationship between the collimation-corrected peak luminosity and the spectral lag, investigating the lag-luminosity relationships in great detail by focusing on spectral lags resulting from all possible combinations of channels. Firstly, we compiled the opening angle data and demonstrated that the distribution of opening angles of 205 long GRBs is represented by a double Gaussian function having maxima at ~ 0.1 and ~ 0.3 radians. We confirmed that the peak luminosity and the spectral lag are anti-correlated, both in the observer frame and in the source frame. We found that, in agreement with our previous conclusion, the correlation coefficient improves significantly in the source frame. It should be noted that spectral lags involving channel 2 (25-50 keV yield high correlation coefficients, where Swift/Burst Alert Telescope (BAT has four energy channels (channel 1: 15-25 keV, channel 2: 25-50 keV, channel 3: 50-100 keV, channel 4: 100-200 keV. We also found that peak luminosity is positively correlated with peak energy.

  4. Ionoacoustic characterization of the proton Bragg peak with submillimeter accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Assmann, W., E-mail: walter.assmann@lmu.de; Reinhardt, S.; Lehrack, S.; Edlich, A.; Thirolf, P. G.; Parodi, K. [Department for Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, Garching 85748 (Germany); Kellnberger, S.; Omar, M.; Ntziachristos, V. [Institute for Biological and Medical Imaging, Technische Universität München and Helmholtz Zentrum München, Ingolstädter Landstrasse 1, Neuherberg 85764 (Germany); Moser, M.; Dollinger, G. [Institute for Applied Physics and Measurement Technology, Universität der Bundeswehr, Werner-Heisenberg-Weg 39, Neubiberg 85577 (Germany)

    2015-02-15

    Purpose: Range verification in ion beam therapy relies to date on nuclear imaging techniques which require complex and costly detector systems. A different approach is the detection of thermoacoustic signals that are generated due to localized energy loss of ion beams in tissue (ionoacoustics). Aim of this work was to study experimentally the achievable position resolution of ionoacoustics under idealized conditions using high frequency ultrasonic transducers and a specifically selected probing beam. Methods: A water phantom was irradiated by a pulsed 20 MeV proton beam with varying pulse intensity and length. The acoustic signal of single proton pulses was measured by different PZT-based ultrasound detectors (3.5 and 10 MHz central frequencies). The proton dose distribution in water was calculated by Geant4 and used as input for simulation of the generated acoustic wave by the matlab toolbox k-WAVE. Results: In measurements from this study, a clear signal of the Bragg peak was observed for an energy deposition as low as 10{sup 12} eV. The signal amplitude showed a linear increase with particle number per pulse and thus, dose. Bragg peak position measurements were reproducible within ±30 μm and agreed with Geant4 simulations to better than 100 μm. The ionoacoustic signal pattern allowed for a detailed analysis of the Bragg peak and could be well reproduced by k-WAVE simulations. Conclusions: The authors have studied the ionoacoustic signal of the Bragg peak in experiments using a 20 MeV proton beam with its correspondingly localized energy deposition, demonstrating submillimeter position resolution and providing a deep insight in the correlation between the acoustic signal and Bragg peak shape. These results, together with earlier experiments and new simulations (including the results in this study) at higher energies, suggest ionoacoustics as a technique for range verification in particle therapy at locations, where the tumor can be localized by ultrasound

  5. Determination of the diagnostic x-ray tube practical peak voltage (PPV) from average or average peak voltage measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hourdakis, C J, E-mail: khour@gaec.gr [Ionizing Radiation Calibration Laboratory-Greek Atomic Energy Commission, PO Box 60092, 15310 Agia Paraskevi, Athens, Attiki (Greece)

    2011-04-07

    The practical peak voltage (PPV) has been adopted as the reference measuring quantity for the x-ray tube voltage. However, the majority of commercial kV-meter models measure the average peak, U-bar{sub P}, the average, U-bar, the effective, U{sub eff} or the maximum peak, U{sub P} tube voltage. This work proposed a method for determination of the PPV from measurements with a kV-meter that measures the average U-bar or the average peak, U-bar{sub p} voltage. The kV-meter reading can be converted to the PPV by applying appropriate calibration coefficients and conversion factors. The average peak k{sub PPV,kVp} and the average k{sub PPV,Uav} conversion factors were calculated from virtual voltage waveforms for conventional diagnostic radiology (50-150 kV) and mammography (22-35 kV) tube voltages and for voltage ripples from 0% to 100%. Regression equation and coefficients provide the appropriate conversion factors at any given tube voltage and ripple. The influence of voltage waveform irregularities, like 'spikes' and pulse amplitude variations, on the conversion factors was investigated and discussed. The proposed method and the conversion factors were tested using six commercial kV-meters at several x-ray units. The deviations between the reference and the calculated - according to the proposed method - PPV values were less than 2%. Practical aspects on the voltage ripple measurement were addressed and discussed. The proposed method provides a rigorous base to determine the PPV with kV-meters from U-bar{sub p} and U-bar measurement. Users can benefit, since all kV-meters, irrespective of their measuring quantity, can be used to determine the PPV, complying with the IEC standard requirements.

  6. Flow visualization

    International Nuclear Information System (INIS)

    Weinstein, L.M.

    1991-01-01

    Flow visualization techniques are reviewed, with particular attention given to those applicable to liquid helium flows. Three techniques capable of obtaining qualitative and quantitative measurements of complex 3D flow fields are discussed including focusing schlieren, particle image volocimetry, and holocinematography (HCV). It is concluded that the HCV appears to be uniquely capable of obtaining full time-varying, 3D velocity field data, but is limited to the low speeds typical of liquid helium facilities. 8 refs

  7. How does economic theory explain the Hubbert peak oil model?

    International Nuclear Information System (INIS)

    Reynes, F.; Okullo, S.; Hofkes, M.

    2010-01-01

    The aim of this paper is to provide an economic foundation for bell shaped oil extraction trajectories, consistent with Hubbert's peak oil model. There are several reasons why it is important to get insight into the economic foundations of peak oil. As production decisions are expected to depend on economic factors, a better comprehension of the economic foundations of oil extraction behaviour is fundamental to predict production and price over the coming years. The investigation made in this paper helps us to get a better understanding of the different mechanisms that may be at work in the case of OPEC and non-OPEC producers. We show that profitability is the main driver behind production plans. Changes in profitability due to divergent trajectories between costs and oil price may give rise to a Hubbert production curve. For this result we do not need to introduce a demand or an exploration effect as is generally assumed in the literature.

  8. Hydrocarbon isotope detection by elastic peak electron spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kostanovskiy, I.A., E-mail: kostanovskiyia@gmail.com [National Research University MPEI, Krasnokazarmennaya 14, 111250 Moscow (Russian Federation); Afanas’ev, V.P. [National Research University MPEI, Krasnokazarmennaya 14, 111250 Moscow (Russian Federation); Naujoks, D. [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstraße 1, D-17491 Greifswald (Germany); Mayer, M. [Max-Planck-Institut für Plasmaphysik, D-85748 Garching (Germany)

    2015-07-15

    Highlights: • PCVD hydrocarbon coatings containing protium or deuterium are analyzed via NRA, ERD, XPS and EPES. • EPES analysis with modern electron energy analyzer SPECS Phoibos 225 shows a clear signal from the hydrogen isotopes. • Different primary energies and scattering angles help to quantify isotope content from EPES spectra. - Abstract: Experimental results on the hydrocarbon isotope analysis by elastic peak electron spectroscopy are presented. Amorphous hydrocarbon samples (a-C:H, a-C:D) are prepared by PCVD and analyzed by nuclear reaction analysis (NRA), elastic recoil detection analysis (ERD), X-ray photoelectron spectroscopy (XPS) and elastic peak electron spectroscopy (EPES). Electron energy spectra show a clear signal from the hydrogen isotopes deuterium and protium. Different incident energies and scattering geometries help to resolve plasmon and elastic energy losses.

  9. Hydrocarbon isotope detection by elastic peak electron spectroscopy

    International Nuclear Information System (INIS)

    Kostanovskiy, I.A.; Afanas’ev, V.P.; Naujoks, D.; Mayer, M.

    2015-01-01

    Highlights: • PCVD hydrocarbon coatings containing protium or deuterium are analyzed via NRA, ERD, XPS and EPES. • EPES analysis with modern electron energy analyzer SPECS Phoibos 225 shows a clear signal from the hydrogen isotopes. • Different primary energies and scattering angles help to quantify isotope content from EPES spectra. - Abstract: Experimental results on the hydrocarbon isotope analysis by elastic peak electron spectroscopy are presented. Amorphous hydrocarbon samples (a-C:H, a-C:D) are prepared by PCVD and analyzed by nuclear reaction analysis (NRA), elastic recoil detection analysis (ERD), X-ray photoelectron spectroscopy (XPS) and elastic peak electron spectroscopy (EPES). Electron energy spectra show a clear signal from the hydrogen isotopes deuterium and protium. Different incident energies and scattering geometries help to resolve plasmon and elastic energy losses

  10. Kinematic evidence for downdip movement on the Mormon Peak detachment

    Science.gov (United States)

    Walker, Christopher D.; Anders, Mark H.; Christie-Blick, Nicholas

    2007-03-01

    The Mormon Peak detachment is considered to be one of the best examples of a rooted upper crustal detachment fault that propagated through the brittle crust at a low angle. The hanging wall of the detachment today consists of a number of isolated blocks that have been interpreted as remnants of a once-contiguous extensional allochthon. Here we present the results of a new study of directional indicators from the basal surfaces beneath these blocks. These measurements do not agree with the long-standing interpretation of a S75°W movement direction for the detachment hanging wall. Instead, the most recent movement on each section of the detachment took place approximately parallel to the present downdip direction. We conclude that the Mormon Peak detachment is best explained as the basal surfaces to a series of rootless gravity slides.

  11. Evaluation of peaking factors uncertainty for CASMO-3

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kang Suk; Song, Jae Seung; Kim, Yong Rae; Ji, Seong Kyun [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-02-01

    This document evaluates the pin-to-box factor uncertainty based on using the CASMO-3 with 40-group J-library. Five CE criticals performed by Westinghouse, two by B and W and four RPI criticals were analyzed, using cross sections by CASMO-3. DOT was used for the core calculation. THis is one hof series of efforts to verify ADONIS procedure which is a new core design package under development by KAERI. The expected outcome of this analysis is CASMO-3 pin peak uncertainty applicable to CE type fuel assembly design. The evaluated uncertainty of peaking factors for CASMO-3 was 1.863%. 21 tabs., 23 figs., 12 refs. (Author) .new.

  12. What is the peak stress in ceramic bar impacts?

    International Nuclear Information System (INIS)

    Simha, C. Hari Manoj; Bless, S.J.; Bedford, A.

    2000-01-01

    The bar impact experiment has been extensively used to characterize the high strain rate properties of high strength ceramics. In particular, alumina AD-99.5 has been widely studied; both stress gauge and VISAR bar impact data are available for this material. We have performed plate-on-bar impact experiments using this material in some novel configurations. An interface was introduced in the target bar (by cutting it) in the zone where the material fails by axial splitting. Such experiments resulted in a dramatic drop in the peak stress measured in the experiment, when compared to experiments with no interface. We show that the damage kinetics in tension influence these measurements. Since the peak stress is dependent on the damage kinetics we conclude that the measurement cannot be correlated to some intrinsic strength of the ceramic

  13. Maximizing utilization of sport halls during peak hours

    DEFF Research Database (Denmark)

    Iversen, Evald Bundgård; Forsberg, Peter

    the number of participants 7.5 persons higher pr. activity compared to club activities. This implies that clubs during peak hours could include more participants. Another possibility to increase utilization is if the management of sport facilities forced sport clubs and other organisers to adapt...... their activities to a smaller amount of floor space, which would make it possible to have more than one activity on the floor at the same time. Hence, to achieve better utilization during prime time, further analysis and research could focus on how activities in sport halls can be adapted to include more......BACKGROUNDDuring peak hours (4.30pm-8pm) demand for timeslots in sport halls in Denmark are high and there are few timeslots available. Further, focus on how public resources are spent most efficient is increasing (Iversen, 2013). This makes it interesting to analyse how utilization could...

  14. RELIABILITY OF THE DETECTION OF THE BARYON ACOUSTIC PEAK

    International Nuclear Information System (INIS)

    MartInez, Vicent J.; Arnalte-Mur, Pablo; De la Cruz, Pablo; Saar, Enn; Tempel, Elmo; Pons-BorderIa, MarIa Jesus; Paredes, Silvestre; Fernandez-Soto, Alberto

    2009-01-01

    The correlation function of the distribution of matter in the universe shows, at large scales, baryon acoustic oscillations, which were imprinted prior to recombination. This feature was first detected in the correlation function of the luminous red galaxies of the Sloan Digital Sky Survey (SDSS). Recently, the final release (DR7) of the SDSS has been made available, and the useful volume is about two times bigger than in the old sample. We present here, for the first time, the redshift-space correlation function of this sample at large scales together with that for one shallower, but denser volume-limited subsample drawn from the Two-Degree Field Redshift Survey. We test the reliability of the detection of the acoustic peak at about 100 h -1 Mpc and the behavior of the correlation function at larger scales by means of careful estimation of errors. We confirm the presence of the peak in the latest data although broader than in previous detections.

  15. In vivo dissolution measurement with indium-111 summation peak ratios

    International Nuclear Information System (INIS)

    Jay, M.; Woodward, M.A.; Brouwer, K.R.

    1985-01-01

    Dissolution of [ 111 In]labeled tablets was measured in vivo in a totally noninvasive manner by using a modification of the perturbed angular correlation technique known as the summation peak ratio method. This method, which requires the incorporation of only 10-12 microCi into the dosage form, provided reliable dissolution data after oral administration of [ 111 In]lactose tablets. These results were supported by in vitro experiments which demonstrated that the dissolution rate as measured by the summation peak ratio method was in close agreement with the dissolution rate of salicylic acid in a [ 111 In]salicylic acid tablet. The method has the advantages of using only one detector, thereby avoiding the need for complex coincidence counting systems, requiring less radioactivity, and being potentially applicable to a gamma camera imaging system

  16. Can double-peaked lines indicate merging effects in AGNs?

    Directory of Open Access Journals (Sweden)

    Popović L.Č.

    2000-01-01

    Full Text Available The influence of merging effects in the central part of an Active Galactic Nucleus (AGN on the emission spectral line shapes are discussed. We present a model of close binary Broad Line Region. The numerical experiments show that the merging effects can explain double peaked lines. The merging effects may also be present in the center of AGNs, although they emit slightly asymmetric as well as symmetric and relatively stable (in profile shape spectral lines. Depending on the black hole masses and their orbit elements such model may explain some of the line profile shapes observed in AGNs. This work shows that if one is looking for the merging effects in the central region as well as in the wide field structure of AGNs, he should first pay attention to objects which have double peaked lines.

  17. Power peak in vicinity of WWER-440 control rod

    International Nuclear Information System (INIS)

    Mikus, J.

    2003-01-01

    The measurements of axial power (fission density) distribution have been performed by means of gamma activity determination (gamma scanning method) of the irradiated fuel pins detecting gamma quanta in the La peak area - 1596.5 keV of their selected parts having 20 mm length in the axial coordinates range 50-950 mm with a 10 mm step using a rectangular collimator (dimensions 20x10 mm). Two NaI(Tl) scintillation crystals (one as a monitor) with diameter of 40 mm were used, each of them in Pb shielding (thickness 150 mm). The obtained results enlarge the available 'power peaking database' and enable validation of the codes also in important case of zero-boron concentration that corresponds to the end of WWER-440 fuel cycle. This validation can improve the reliability of the calculation results of the power distribution in WWER-440 cores, re-loading schemes etc

  18. Flow regimes

    International Nuclear Information System (INIS)

    Liles, D.R.

    1982-01-01

    Internal boundaries in multiphase flow greatly complicate fluid-dynamic and heat-transfer descriptions. Different flow regimes or topological configurations can have radically dissimilar interfacial and wall mass, momentum, and energy exchanges. To model the flow dynamics properly requires estimates of these rates. In this paper the common flow regimes for gas-liquid systems are defined and the techniques used to estimate the extent of a particular regime are described. Also, the current computer-code procedures are delineated and introduce a potentially better method is introduced

  19. Implementing peak load reduction algorithms for household electrical appliances

    International Nuclear Information System (INIS)

    Dlamini, Ndumiso G.; Cromieres, Fabien

    2012-01-01

    Considering household appliance automation for reduction of household peak power demand, this study explored aspects of the interaction between household automation technology and human behaviour. Given a programmable household appliance switching system, and user-reported appliance use times, we simulated the load reduction effectiveness of three types of algorithms, which were applied at both the single household level and across all 30 households. All three algorithms effected significant load reductions, while the least-to-highest potential user inconvenience ranking was: coordinating the timing of frequent intermittent loads (algorithm 2); moving period-of-day time-flexible loads to off-peak times (algorithm 1); and applying short-term time delays to avoid high peaks (algorithm 3) (least accommodating). Peak reduction was facilitated by load interruptibility, time of use flexibility and the willingness of users to forgo impulsive appliance use. We conclude that a general factor determining the ability to shift the load due to a particular appliance is the time-buffering between the service delivered and the power demand of an appliance. Time-buffering can be ‘technologically inherent’, due to human habits, or realised by managing user expectations. There are implications for the design of appliances and home automation systems. - Highlights: ► We explored the interaction between appliance automation and human behaviour. ► There is potential for considerable load shifting of household appliances. ► Load shifting for load reduction is eased with increased time buffering. ► Design, human habits and user expectations all influence time buffering. ► Certain automation and appliance design features can facilitate load shifting.

  20. On intrinsic and extrinsic origin of plasmon peaks

    International Nuclear Information System (INIS)

    Takayama, Shoichi; Kawai, Jun

    2008-01-01

    The origin of the plasmon loss peaks in X-ray photoelectron spectra are discussed based on the (1) intrinsic, (2) extrinsic, (3) quantum interference between (1) and (2), and (4) mixture of (1) and (2). It was believed that the major part of plasmon was due to the extrinsic, the present analysis concludes the major part is intrinsic, depending the excitation energy. This analysis is based on the electron reflection spectra, but valid for X-ray photoelectron spectra. (author)

  1. Problems of peak demands in the gas industry

    Energy Technology Data Exchange (ETDEWEB)

    Haeberlin, A

    1979-01-01

    After a brief explanation of the demands made on gas supply enterprises, a discussion of the possibilities of optimization for meeting the demand follows. There are in principle two possibilities for this: the interruption of deliveries which should be made legal in a contract and the use of peak supply plants, especially in the form of gas storages. The procedure is chosen according to the special situation of each gas supply enterprise.

  2. PeakForce Tapping resolves individual microvilli on living cells.

    Science.gov (United States)

    Schillers, Hermann; Medalsy, Izhar; Hu, Shuiqing; Slade, Andrea L; Shaw, James E

    2016-02-01

    Microvilli are a common structure found on epithelial cells that increase the apical surface thus enhancing the transmembrane transport capacity and also serve as one of the cell's mechanosensors. These structures are composed of microfilaments and cytoplasm, covered by plasma membrane. Epithelial cell function is usually coupled to the density of microvilli and its individual size illustrated by diseases, in which microvilli degradation causes malabsorption and diarrhea. Atomic force microscopy (AFM) has been widely used to study the topography and morphology of living cells. Visualizing soft and flexible structures such as microvilli on the apical surface of a live cell has been very challenging because the native microvilli structures are displaced and deformed by the interaction with the probe. PeakForce Tapping® is an AFM imaging mode, which allows reducing tip-sample interactions in time (microseconds) and controlling force in the low pico-Newton range. Data acquisition of this mode was optimized by using a newly developed PeakForce QNM-Live Cell probe, having a short cantilever with a 17-µm-long tip that minimizes hydrodynamic effects between the cantilever and the sample surface. In this paper, we have demonstrated for the first time the visualization of the microvilli on living kidney cells with AFM using PeakForce Tapping. The structures observed display a force dependence representing either the whole microvilli or just the tips of the microvilli layer. Together, PeakForce Tapping allows force control in the low pico-Newton range and enables the visualization of very soft and flexible structures on living cells under physiological conditions. © 2015 The Authors Journal of Molecular Recognition Published by John Wiley & Sons Ltd.

  3. Genetic and Dynamic Analyses of Murine Peak Bone Density

    Science.gov (United States)

    1999-10-01

    bone density in mice. Femurs from young adult B6, C3H, and CAST females at 4 months of age were measured by pQCT (XCT-960M, Norland Med Sys., Ft...progenitor strains - B6, C3H, and CAST - showed that adult skeletal peak BMD was established at 4 months. Therefore, F2 mice were necropsied at 4...calcium depletion causes hypocalcemia , which leads to secondary hyperparathyroidism, subsequently resulting in increased bone resorption. Conversely

  4. BENEFITS OF WILDERNESS EXPANSION WITH EXCESS DEMAND FOR INDIAN PEAKS

    OpenAIRE

    Walsh, Richard G.; Gilliam, Lynde O.

    1982-01-01

    The contingent valuation approach was applied to the problem of estimating the recreation benefits from alleviating congestion at Indian Peaks wilderness area, Colorado. A random sample of 126 individuals were interviewed while hiking and backpacking at the study site in 1979. The results provide an empirical test and confirmation of the Cesario and Freeman proposals that under conditions of excess recreational demand for existing sites, enhanced opportunities to substitute newly designated s...

  5. Degradation of the Bragg peak due to inhomogeneities.

    Science.gov (United States)

    Urie, M; Goitein, M; Holley, W R; Chen, G T

    1986-01-01

    The rapid fall-off of dose at the end of range of heavy charged particle beams has the potential in therapeutic applications of sparing critical structures just distal to the target volume. Here we explored the effects of highly inhomogeneous regions on this desirable depth-dose characteristic. The proton depth-dose distribution behind a lucite-air interface parallel to the beam was bimodal, indicating the presence of two groups of protons with different residual ranges, creating a step-like depth-dose distribution at the end of range. The residual ranges became more spread out as the interface was angled at 3 degrees, and still more at 6 degrees, to the direction of the beam. A second experiment showed little significant effect on the distal depth-dose of protons having passed through a mosaic of teflon and lucite. Anatomic studies demonstrated significant effects of complex fine inhomogeneities on the end of range characteristics. Monoenergetic protons passing through the petrous ridges and mastoid air cells in the base of skull showed a dramatic degradation of the distal Bragg peak. In beams with spread out Bragg peaks passing through regions of the base of skull, the distal fall-off from 90 to 20% dose was increased from its nominal 6 to well over 32 mm. Heavy ions showed a corresponding degradation in their ends of range. In the worst case in the base of skull region, a monoenergetic neon beam showed a broadening of the full width at half maximum of the Bragg peak to over 15 mm (compared with 4 mm in a homogeneous unit density medium). A similar effect was found with carbon ions in the abdomen, where the full width at half maximum of the Bragg peak (nominally 5.5 mm) was found to be greater than 25 mm behind gas-soft-tissue interfaces. We address the implications of these data for dose computation with heavy charged particles.

  6. EMPIRICALLY DERIVED INTEGRATED STELLAR YIELDS OF Fe-PEAK ELEMENTS

    International Nuclear Information System (INIS)

    Henry, R. B. C.; Cowan, John J.; Sobeck, Jennifer

    2010-01-01

    We present here the initial results of a new study of massive star yields of Fe-peak elements. We have compiled from the literature a database of carefully determined solar neighborhood stellar abundances of seven iron-peak elements, Ti, V, Cr, Mn, Fe, Co, and Ni, and then plotted [X/Fe] versus [Fe/H] to study the trends as functions of metallicity. Chemical evolution models were then employed to force a fit to the observed trends by adjusting the input massive star metallicity-sensitive yields of Kobayashi et al. Our results suggest that yields of Ti, V, and Co are generally larger as well as anticorrelated with metallicity, in contrast to the Kobayashi et al. predictions. We also find the yields of Cr and Mn to be generally smaller and directly correlated with metallicity compared to the theoretical results. Our results for Ni are consistent with theory, although our model suggests that all Ni yields should be scaled up slightly. The outcome of this exercise is the computation of a set of integrated yields, i.e., stellar yields weighted by a slightly flattened time-independent Salpeter initial mass function and integrated over stellar mass, for each of the above elements at several metallicity points spanned by the broad range of observations. These results are designed to be used as empirical constraints on future iron-peak yield predictions by stellar evolution modelers. Special attention is paid to the interesting behavior of [Cr/Co] with metallicity-these two elements have opposite slopes-as well as the indirect correlation of [Ti/Fe] with [Fe/H]. These particular trends, as well as those exhibited by the inferred integrated yields of all iron-peak elements with metallicity, are discussed in terms of both supernova nucleosynthesis and atomic physics.

  7. Automatic acquisition and shape analysis of metastable peaks

    International Nuclear Information System (INIS)

    Maendli, H.; Robbiani, R.; Kuster, Th.; Seibl, J.

    1979-01-01

    A method for automatic acquisition and evaluation of metastable peaks due to transitions in the first field-free region of a double focussing mass spectrometer is presented. The data are acquired by computer-controlled repetitive scanning of the accelerating voltage and concomitant accumulation, the evaluation made by a mathematical derivatization of the resulting curve. Examples for application of the method are given. (Auth.)

  8. Bulk power system performance issues affecting utility peaking capacity additions

    Energy Technology Data Exchange (ETDEWEB)

    Garrity, T.F. [GE Power Sytems, Schenectady, NY (United States)

    1994-12-31

    This paper presents a discussion of transmission system constraints and problems that affect the siting and rating of peaking capacity additions. Techniques for addressing and modifying these concerns are presented. Particular attention is paid to techniques that have been successfully used by utilities to improve power transfer and system loadability, while avoiding the construction of additional transmission lines. Proven techniques for dealing with thermal, short-circuit level and stability issues are presented.

  9. Medium Term Economic Effects of Peak Oil Today

    OpenAIRE

    Dr. Ulrike Lehr; Dr. Christian Lutz; Kirsten Wiebe

    2011-01-01

    The paper at hand presents results of a model-based scenario analysis on the economic implications in the next decade of an oil peak today and significantly decreasing oil production in the coming years. For that the extraction paths of oil and other fossil fuels given in LBST (2010) are implemented in the global macroeconomic model GINFORS. Additionally, the scenarios incorporate different technological potentials for energy efficiency and renewable energy, which cannot be forecast using eco...

  10. Cranial Indicators Identified for Peak Incidence of Otitis Media.

    Science.gov (United States)

    Pagano, Anthony S; Wang, Eugene; Yuan, Derek; Fischer, Daniel; Bluestone, Charles; Marquez, Samuel; Laitman, Jeffrey

    2017-10-01

    Acute otitis media (AOM) is one of the most common pediatric conditions worldwide. Peak age of occurrence for AOM has been identified within the first postnatal year and it remains frequent until approximately six postnatal years. Morphological differences between adults and infants in the cartilaginous Eustachian tube (CET) and associated structures may be responsible for development of this disease yet few have investigated normal growth trajectories. We tested hypotheses on coincidence of skeletal growth changes and known ages of peak AOM occurrence. Growth was divided into five dental eruption stages ranging from edentulous neonates (Stage 1) to adults with erupted third maxillary molars (Stage 5). A total of 32 three-dimensional landmarks were used and Generalized Procrustes Analysis was performed. Next, we performed principal components analysis and calculated univariate measures. It was found that growth change in Stage 1 was the most rapid and comprised the largest amount of overall growth in upper respiratory tract proportions (where time is represented by the natural logarithmic transformation of centroid size). The analysis of univariate measures showed that Stage 1 humans did indeed possess the relatively shortest and most horizontally oriented CET's with the greatest amount of growth change occurring at the transition to Stage 2 (eruption of deciduous dentition at five postnatal months, commencing peak AOM incidence) and ceasing by Stage 3 (approximately six postnatal years). Skeletal indicators appear related to peak ages of AOM incidence and may contribute to understanding of a nearly ubiquitous human disease. Anat Rec, 2017. © 2017 Wiley Periodicals, Inc. Anat Rec, 300:1721-1740, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  11. Flujo espiratorio máximo en niños asmáticos: Casos y controles

    Directory of Open Access Journals (Sweden)

    Arturo Recabarren Lozada

    1995-04-01

    Full Text Available Con el fin de determinar las variaciones del Flujo Espiratorio Máximo (PEF, se estudiaron a 38 niños asmáticos (CASOS en período intercrítico de la enfermedad y a 38 niños sanos (CONTROLES, de ambos sexos comprendidos entre los 5 y 15 años de edad. Los niños asmáticos fueron clasificados por parámetros clínicos en determinado grado de severidad de asma bronquial, determinando el PEF de cada niño objeto de estudio conel mini-Wright Peak Flow Meter, en 2 registros diarios a los 06 y 18 horas, durante 7 días consecutivos, obteniendo la variabilidad del mismo. Se encuentra diferencia en la variabilidad global de niños asmáticos de todos los grados de severidad de la enfermedad comprada con la de los niños normales, con diferencia estadística altamente significativa (p<0.000001. Las variaciones diurnas del PEF ayuda en el diagnóstico del asma bronquial y también son útiles para realizar la catalogación de severidad de la enfermedad. El PEF correlaciona bien con los síntomas presentados por los pacientes y por lo tanto guarda correspondencia con la Hiperreactividad bronquial (HRB del niño asmático. Postulamos que un niño con historia clínica sugestiva, una variabilidad global mayor del 8% indica que el diagnóstico de asma es altamente probable (Rev Med Hered 1995; 6: 76-82

  12. Analytical solutions for peak and residual uplift resistance of pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Nixon, J.F. [Nixon Geotech Ltd., Calgary, AB (Canada); Oswell, J.M. [Naviq Consulting Inc., Calgary, AB (Canada)

    2010-07-01

    Frost heave can occur on cold pipelines that traverse unfrozen, non permafrost terrain. The stresses experienced by the pipeline are partly a function of the strength of the soil on the non heaving side of the frozen-unfrozen interface. This paper proposed three analytical solutions to estimate the soil uplift resistance by considering the pipeline and soil to act similar to a strip footing, a punching shear failure, and by considering the formation of horizontal crack emanating from the spring line of the pipe. Peak uplift resistance and residual uplift resistance were discussed. Results for full scale pipe and for laboratory scale model pipes were presented, with particular reference to cover depth, temperature and crack width; and limits to residual uplift resistance. It was concluded that the peak uplift resistance and the residual uplift resistance are generally independent and controlled by different factors. The peak resistance is related directly to pipe diameter, and less strongly dependent on springline depth. It is also strongly dependent on soil temperature. However, the residual uplift resistance is strongly dependent on burial depth, weakly dependent on pipe displacement rate and also on soil temperature. 15 refs., 19 figs.

  13. High peak power tubes and gate effect Klystrons

    International Nuclear Information System (INIS)

    Gerbelot, N.; Bres, M.; Faillon, G.; Buzzi, J.M.

    1993-01-01

    The conventional microwave tubes such as TWTs, Magnetrons, Klystrons... deliver the very high peak powers which are required by radar transmitters but more especially by many particle accelerators. In the range of a few hundred MHz to about 10 GHz, some dozen of MWs per unit are currently obtained and commercially available, according to the frequency and the pulse lengths. But peak power requirements are ever increasing, especially for the expected new linear particle acceleratores, where several hundred MWs per tube would be necessary. Also some special military transmitters begin to request GW pulses, with short pulse lengths - of course - but at nonnegligible repetition rates. Therefore several laboratories and microwave vacuum tube manufacturers have engaged - for several years - studies and development in the field of very high peak microwave power (HPM) toward two main directions: extended operation and extrapolation of the conventional tubes and devices; development of new concepts, among which the most promising are likely the high-current relativistic klystrons - that are also referred to as gate effect klystrons

  14. Mineral Resources: Reserves, Peak Production and the Future

    Directory of Open Access Journals (Sweden)

    Lawrence D. Meinert

    2016-02-01

    Full Text Available The adequacy of mineral resources in light of population growth and rising standards of living has been a concern since the time of Malthus (1798, but many studies erroneously forecast impending peak production or exhaustion because they confuse reserves with “all there is”. Reserves are formally defined as a subset of resources, and even current and potential resources are only a small subset of “all there is”. Peak production or exhaustion cannot be modeled accurately from reserves. Using copper as an example, identified resources are twice as large as the amount projected to be needed through 2050. Estimates of yet-to-be discovered copper resources are up to 40-times more than currently-identified resources, amounts that could last for many centuries. Thus, forecasts of imminent peak production due to resource exhaustion in the next 20–30 years are not valid. Short-term supply problems may arise, however, and supply-chain disruptions are possible at any time due to natural disasters (earthquakes, tsunamis, hurricanes or political complications. Needed to resolve these problems are education and exploration technology development, access to prospective terrain, better recycling and better accounting of externalities associated with production (pollution, loss of ecosystem services and water and energy use.

  15. MERGERS IN DOUBLE-PEAKED [O III] ACTIVE GALACTIC NUCLEI

    International Nuclear Information System (INIS)

    Fu Hai; Djorgovski, S. G.; Myers, Adam D.; Yan Lin

    2011-01-01

    As a natural consequence of galaxy mergers, binary active galactic nuclei (AGNs) should be commonplace. Nevertheless, observational confirmations are rare, especially for binaries with separations less than 10 kpc. Such a system may show two sets of narrow emission lines in a single spectrum owing to the orbital motion of the binary. We have obtained high-resolution near-infrared images of 50 double-peaked [O III]λ5007 AGNs with the Keck II laser guide star adaptive optics system. The Sloan Digital Sky Survey sample is compiled from the literature and consists of 17 type-1 AGNs between 0.18 BH -σ * relation because of overestimated stellar velocity dispersions, illustrating the importance of removing mergers from the samples defining the M BH -σ * relations. Finally, we find that the emission-line properties are indistinguishable for spatially resolved and unresolved sources, emphasizing that scenarios involving a single AGN can produce the same double-peaked line profiles and they account for at least 70% of the double-peaked [O III] AGNs.

  16. Martial arts striking hand peak acceleration, accuracy and consistency.

    Science.gov (United States)

    Neto, Osmar Pinto; Marzullo, Ana Carolina De Miranda; Bolander, Richard P; Bir, Cynthia A

    2013-01-01

    The goal of this paper was to investigate the possible trade-off between peak hand acceleration and accuracy and consistency of hand strikes performed by martial artists of different training experiences. Ten male martial artists with training experience ranging from one to nine years volunteered to participate in the experiment. Each participant performed 12 maximum effort goal-directed strikes. Hand acceleration during the strikes was obtained using a tri-axial accelerometer block. A pressure sensor matrix was used to determine the accuracy and consistency of the strikes. Accuracy was estimated by the radial distance between the centroid of each subject's 12 strikes and the target, whereas consistency was estimated by the square root of the 12 strikes mean squared distance from their centroid. We found that training experience was significantly correlated to hand peak acceleration prior to impact (r(2)=0.456, p =0.032) and accuracy (r(2)=0. 621, p=0.012). These correlations suggest that more experienced participants exhibited higher hand peak accelerations and at the same time were more accurate. Training experience, however, was not correlated to consistency (r(2)=0.085, p=0.413). Overall, our results suggest that martial arts training may lead practitioners to achieve higher striking hand accelerations with better accuracy and no change in striking consistency.

  17. The bias of weighted dark matter halos from peak theory

    CERN Document Server

    Verde, Licia; Simpson, Fergus; Alvarez-Gaume, Luis; Heavens, Alan; Matarrese, Sabino

    2014-01-01

    We give an analytical form for the weighted correlation function of peaks in a Gaussian random field. In a cosmological context, this approach strictly describes the formation bias and is the main result here. Nevertheless, we show its validity and applicability to the evolved cosmological density field and halo field, using Gaussian random field realisations and dark matter N-body numerical simulations. Using this result from peak theory we compute the bias of peaks (and dark matter halos) and show that it reproduces results from the simulations at the ${\\mathcal O}(10\\%)$ level. Our analytical formula for the bias predicts a scale-dependent bias with two characteristics: a broad band shape which, however, is most affected by the choice of weighting scheme and evolution bias, and a more robust, narrow feature localised at the BAO scale, an effect that is confirmed in simulations. This scale-dependent bias smooths the BAO feature but, conveniently, does not move it. We provide a simple analytic formula to des...

  18. Predictors of the peak width for networks with exponential links

    Science.gov (United States)

    Troutman, B.M.; Karlinger, M.R.

    1989-01-01

    We investigate optimal predictors of the peak (S) and distance to peak (T) of the width function of drainage networks under the assumption that the networks are topologically random with independent and exponentially distributed link lengths. Analytical results are derived using the fact that, under these assumptions, the width function is a homogeneous Markov birth-death process. In particular, exact expressions are derived for the asymptotic conditional expectations of S and T given network magnitude N and given mainstream length H. In addition, a simulation study is performed to examine various predictors of S and T, including N, H, and basin morphometric properties; non-asymptotic conditional expectations and variances are estimated. The best single predictor of S is N, of T is H, and of the scaled peak (S divided by the area under the width function) is H. Finally, expressions tested on a set of drainage basins from the state of Wyoming perform reasonably well in predicting S and T despite probable violations of the original assumptions. ?? 1989 Springer-Verlag.

  19. A new record peak luminosity for the LHC

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Two weeks of dedicated machine development paid off last weekend when the LHC ran for physics with three nominal intensity (∼1011 protons) bunches in each beam.   This brought a new record peak luminosity of around 8×1029 cm-2 s-1, and allowed the LHC to double the integrated luminosity delivered to the experiments since 30 March from 16 to 32 inverse nanobarns over the weekend. After a few more fills in this configuration, the number of bunches will be raised to six per beam, which will in turn allow the peak luminosity to break the 1030 cm-2 s-1 barrier for the first time, well on the way to achieving the 2010 objective of 1032 cm-2 s-1. This peak luminosity goal requires 800 nominal bunches per beam squeezed to a beta of 3.5 metres. The plan for 2011 is to run the LHC in this configuration over about 10 months, thus achieving the objective of recording one inverse femtobarn of data in total. The machine development period also allowed the TOTEM detectors to be set up with 45...

  20. Peak reduction for commercial buildings using energy storage

    Science.gov (United States)

    Chua, K. H.; Lim, Y. S.; Morris, S.

    2017-11-01

    Battery-based energy storage has emerged as a cost-effective solution for peak reduction due to the decrement of battery’s price. In this study, a battery-based energy storage system is developed and implemented to achieve an optimal peak reduction for commercial customers with the limited energy capacity of the energy storage. The energy storage system is formed by three bi-directional power converter rated at 5 kVA and a battery bank with capacity of 64 kWh. Three control algorithms, namely fixed-threshold, adaptive-threshold, and fuzzy-based control algorithms have been developed and implemented into the energy storage system in a campus building. The control algorithms are evaluated and compared under different load conditions. The overall experimental results show that the fuzzy-based controller is the most effective algorithm among the three controllers in peak reduction. The fuzzy-based control algorithm is capable of incorporating a priori qualitative knowledge and expertise about the load characteristic of the buildings as well as the useable energy without over-discharging the batteries.

  1. Noise distribution of a peak track and hold circuit

    International Nuclear Information System (INIS)

    Seller, Paul; Hardie, Alec L.; Morrissey, Quentin

    2012-01-01

    Noise in linear electronic circuits is well characterised in terms of power spectral density in the frequency domain and the Normal probability density function in the time domain. For instance a charge preamplifier followed by a simple time independent pulse shaping circuit produces an output with a predictable, easily calculated Normal density function. By the Ergodic Principle this is true if the signal is sampled randomly in time or the experiment is run many times and measured at a fixed time after the circuit is released from reset. Apart from well defined cases, the time of the sample after release of reset does not affect the density function. If this signal is then passed through a peak track-and-hold circuit the situation is very different. The probability density function of the sampled signal is no longer Normal and the function changes with the time of the sample after release of reset. This density function can be classified by the Gumbel probability density function which characterises the Extreme Value Distribution of a defined number of Normally distributed values. The number of peaks in the signal is an important factor in the analysis. This issue is analysed theoretically and compared with a time domain noise simulation programme. This is then related to a real electronic circuit used for low-noise X-ray measurements and shows how the low-energy resolution of this system is significantly degraded when using a peak track-and-hold.

  2. The GRB variability/peak luminosity correlation: new results

    International Nuclear Information System (INIS)

    Guidorzi, C.; Rossi, F.; Hurley, K.; Mundell, C.G.

    2005-01-01

    We test the correlation between time variability and isotropic-equivalent peak luminosity found by Reichart et al. (ApJ, 552 (2001) 57) using a set of 26 Gamma-Ray Bursts (GRBs) with known redshift. We confirm the correlation, thought with a larger spread around the best-fit power-law obtained by Reichart et al. which in turn does not provide an acceptable description any longer. In addiction, we find no evidence for correlation between variability and beaming-corrected peak luminosity for a subset of 14 GRBs whose beaming angles have been taken from Ghirlanda et al. (ApJ, 616 (2004) 331). Finally, we investigate the possible connection for some GRBs between the location in the variability/peak luminosity space and some afterglow properties, such as the detectability in the optical band, by adding some GRBs whose redshifts, unknown from direct measurements, have been derived assuming the Amati at al. (AeA, 390 (2002) 81) relationship

  3. Physical performance and peak aerobic power at different body temperatures.

    Science.gov (United States)

    Bergh, U; Ekblom, B

    1979-05-01

    In eight male subjects we studied the effect of different core (esophageal, (Tes 34.9--38.4 degrees C) and muscle (Tm 35.1--39.3 degrees C) temperature on 1) physical performance (time to exhaustion at a standard maximal rate of work, WT), 2) aerobic power (VO2), 3) heart rate (HR), and 4) blood lactate (LA) concentration during exhaustive combined arm and leg exercise. In three subjects the effects at different mean skin temperatures (Tsk 27 and 31 degrees C, respectively) were also studied. Peak VO2 was positively correlated to both Tes (r = 0.88) and Tm (r = 0.91). None of the subjects attained control VO2max at Tes and Tm lower than 37.5 and 38.0 degrees C, respectively. HR was correlated to both Tes (r = 0.97) and Tm (r = 0.95). Different Tsk did not affect peak VO2 and HR at subnormal body temperatures. Pulmonary ventilation was independent of Tes and Tm in all experimental situations. LA was significantly higher at Tes 37.5 degrees C compared to both Tes 34.9 and 38.5 degrees C, respectively. At Tes less than 37.5 degrees C and Tm less than 38.0 degrees C, there was a linear reduction in WT (20%.degrees C-1), peak VO2 (5--6%.degrees C-1), and HR (8 beats.min-1.degrees C-1) with lowered Tes and Tm.

  4. Nominal Range Sensitivity Analysis of peak radionuclide concentrations in randomly heterogeneous aquifers

    International Nuclear Information System (INIS)

    Cadini, F.; De Sanctis, J.; Cherubini, A.; Zio, E.; Riva, M.; Guadagnini, A.

    2012-01-01

    Highlights: ► Uncertainty quantification problem associated with the radionuclide migration. ► Groundwater transport processes simulated within a randomly heterogeneous aquifer. ► Development of an automatic sensitivity analysis for flow and transport parameters. ► Proposal of a Nominal Range Sensitivity Analysis approach. ► Analysis applied to the performance assessment of a nuclear waste repository. - Abstract: We consider the problem of quantification of uncertainty associated with radionuclide transport processes within a randomly heterogeneous aquifer system in the context of performance assessment of a near-surface radioactive waste repository. Radionuclide migration is simulated at the repository scale through a Monte Carlo scheme. The saturated groundwater flow and transport equations are then solved at the aquifer scale for the assessment of the expected radionuclide peak concentration at a location of interest. A procedure is presented to perform the sensitivity analysis of this target environmental variable to key parameters that characterize flow and transport processes in the subsurface. The proposed procedure is exemplified through an application to a realistic case study.

  5. Climate change and peak demand for electricity: Evaluating policies for reducing peak demand under different climate change scenarios

    Science.gov (United States)

    Anthony, Abigail Walker

    This research focuses on the relative advantages and disadvantages of using price-based and quantity-based controls for electricity markets. It also presents a detailed analysis of one specific approach to quantity based controls: the SmartAC program implemented in Stockton, California. Finally, the research forecasts electricity demand under various climate scenarios, and estimates potential cost savings that could result from a direct quantity control program over the next 50 years in each scenario. The traditional approach to dealing with the problem of peak demand for electricity is to invest in a large stock of excess capital that is rarely used, thereby greatly increasing production costs. Because this approach has proved so expensive, there has been a focus on identifying alternative approaches for dealing with peak demand problems. This research focuses on two approaches: price based approaches, such as real time pricing, and quantity based approaches, whereby the utility directly controls at least some elements of electricity used by consumers. This research suggests that well-designed policies for reducing peak demand might include both price and quantity controls. In theory, sufficiently high peak prices occurring during periods of peak demand and/or low supply can cause the quantity of electricity demanded to decline until demand is in balance with system capacity, potentially reducing the total amount of generation capacity needed to meet demand and helping meet electricity demand at the lowest cost. However, consumers need to be well informed about real-time prices for the pricing strategy to work as well as theory suggests. While this might be an appropriate assumption for large industrial and commercial users who have potentially large economic incentives, there is not yet enough research on whether households will fully understand and respond to real-time prices. Thus, while real-time pricing can be an effective tool for addressing the peak load

  6. Automated Critical Peak Pricing Field Tests: Program Descriptionand Results

    Energy Technology Data Exchange (ETDEWEB)

    Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Xu, Peng

    2006-04-06

    California utilities have been exploring the use of critical peak prices (CPP) to help reduce needle peaks in customer end-use loads. CPP is a form of price-responsive demand response (DR). Recent experience has shown that customers have limited knowledge of how to operate their facilities in order to reduce their electricity costs under CPP (Quantum 2004). While the lack of knowledge about how to develop and implement DR control strategies is a barrier to participation in DR programs like CPP, another barrier is the lack of automation of DR systems. During 2003 and 2004, the PIER Demand Response Research Center (DRRC) conducted a series of tests of fully automated electric demand response (Auto-DR) at 18 facilities. Overall, the average of the site-specific average coincident demand reductions was 8% from a variety of building types and facilities. Many electricity customers have suggested that automation will help them institutionalize their electric demand savings and improve their overall response and DR repeatability. This report focuses on and discusses the specific results of the Automated Critical Peak Pricing (Auto-CPP, a specific type of Auto-DR) tests that took place during 2005, which build on the automated demand response (Auto-DR) research conducted through PIER and the DRRC in 2003 and 2004. The long-term goal of this project is to understand the technical opportunities of automating demand response and to remove technical and market impediments to large-scale implementation of automated demand response (Auto-DR) in buildings and industry. A second goal of this research is to understand and identify best practices for DR strategies and opportunities. The specific objectives of the Automated Critical Peak Pricing test were as follows: (1) Demonstrate how an automated notification system for critical peak pricing can be used in large commercial facilities for demand response (DR). (2) Evaluate effectiveness of such a system. (3) Determine how customers

  7. Characterization of Fractures in the Chicxulub Peak Ring: Preliminary Results from IODP/ICDP Expedition 364

    Science.gov (United States)

    McCall, N.; Gulick, S. P. S.; Morgan, J. V.; Hall, B. J.; Jones, L.; Expedition 364 Science Party, I. I.

    2017-12-01

    During Expedition 364, IODP/ICDP drilled the peak ring of the Chicxulub impact crater at Site M0077, recovering core from 505.7 to 1334.7 mbsf. The core has been imaged via X-ray Computer Tomography (CT) as a noninvasive method to create a 3-dimensional model of the core, providing information on the density and internal structure at a 0.3 mm resolution. Results from the expedition show that from 748 mbsf and deeper the peak ring is largely composed of uplifted and fractured granitic basement rocks originally sourced from approximately 8-10 km depth. Impact crater modeling suggests the peak ring was formed through dynamic collapse of a rebounding central peak within 10 minutes of impact, requiring the target rocks to temporarily behave as a viscous fluid. The newly recovered core provides a rare opportunity to investigate the cratering process, specifically how the granite was weakened, as well as the extent of the hydrothermal system created after the impact. Based on the CT data, we identify four classes of fractures based on their CT facies deforming the granitoids: pervasive fine fractures, discrete fine fractures, discrete filled fractures, and discrete open fractures. Pervasive fine fractures were most commonly found proximal to dikes and impact melt rock. Discrete filled fractures often displayed a cataclastic texture. We present density trends for the different facies and compare these to petrophysical properties (density, NGR, P-wave seismic velocity). Fractured areas have a lower density than the surrounding granite, as do most filled fractures. This reduction suggests that fluid migrating through the peak ring in the wake of the impact either deposited lower density minerals within the fractures and/or altered the original fracture fill. The extent and duration of fluid flow recorded in these fractures will assist in the characterization of the post-impact hydrothermal system. Future work includes combining information from CT images with thin sections

  8. Peaking cladding temperature and break equivalent size of intermediate break loss of coolant accident

    International Nuclear Information System (INIS)

    Luo Bangqi

    2012-01-01

    The analysis results of intermediate break loss of coolant accident for the nuclear power plant of million kw level showed to be as following: (1) At the begin of life, the break occur simultaneity reactor shutdown with L(X)P. it's equivalent break size and peaking cladding temperature is respectively 20 cm and 849℃. (2) At the begin of life, the break occur simultaneity reactor shutdown without loop. the reactor coolant pumps will be stop after reactor shutdown 10 minutes, it's equivalent break size and peaking cladding temperature is respectively 10.5 cm and 921℃. (3) At the bur up of 31 GWd/t(EOC1). the break occur simultaneity reactor shutdown without loop, the reactor coolant pumps will be stop after reactor shutdown 20 minutes, it's equivalent break size and peaking cladding temperature is respectively 8 cm and 1145℃. The above analysis results showed that the peaking cladding temperature of intermediate break loss of coolant accident is not only related with the break equivalent size and core bur up, and is closely related with the stop time of coolant pumps because the coolant pumps would drive the coolant from safety system to produce the seal loop in break loop and affect the core coolant flow, results in the fuel cladding temperature increasing or damaging. Therefore, the break spectrum, burn up spectrum, the stop time of coolant pumps and operator action time will need to detail analysis and provide appropriate operating procedure, otherwise the peaking cladding temperature will exceed 1204℃ and threaten the safety of the reactor core when the intermediate break loss of coolant accident occur in some break equivalent size, burn up, stop pumps time and operator action not appropriate. The pressurizer pressure low signal simultaneity containment pressure higher signal were used as the operator manual close the signal of reactor coolant pumps after reactor shutdown of 20 minutes. have successful solved the operator intervention time from 10 minutes

  9. Current status of the quantification of roughness and the peak shear strength criteria for rock joints

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byoung Yoon; Kang, Chul Hyung

    1999-04-01

    In order to understand the effects of spent nuclear fuel on the hydraulic behaviour of the rock mass it is necessary to have knowledge about the relationship between the stresses and hydraulic properties of the fractures. The roughness of a fracture surface govern the dilation of the fracture and the displacement of the fracture surface under shear stress. The peak shear strength and hydraulic flow properties of fractures depend very much on the surface roughness. This report describes different methods and techniques used in the characterization of rock joint surfaces and their applications in rock mechanics. Joint roughness is an important factor in the shear resistance of a joint. The joint shear strength shows anisotropic properties due to roughness variation with the shearing direction in direct shear tests. Various shear strength criteria are described in this report. (author)

  10. Bayesian statistical evaluation of peak area measurements in gamma spectrometry

    International Nuclear Information System (INIS)

    Silva, L.; Turkman, A.; Paulino, C.D.

    2010-01-01

    We analyze results from determinations of peak areas for a radioactive source containing several radionuclides. The statistical analysis was performed using Bayesian methods based on the usual Poisson model for observed counts. This model does not appear to be a very good assumption for the counting system under investigation, even though it is not questioned as a whole by the inferential procedures adopted. We conclude that, in order to avoid incorrect inferences on relevant quantities, one must proceed to a further study that allows us to include missing influence parameters and to select a model explaining the observed data much better.

  11. Periodic permanent magnet focusing system with high peak field

    International Nuclear Information System (INIS)

    Zhang Hong; Liu Weiwei; Bai Shuxin; Chen Ke

    2008-01-01

    In this study, hybrid periodic permanent magnet (PPM) system is studied, which has high axial magnetic field and low magnetic leakage. By simulation computation, some laws of magnetic field distribution vs. structure dimensions were obtained. A hybrid PPM is designed and constructed whose peak field reaches 0.6 T. The factors inducing discrepancies between computational results and practical measurements are analyzed. The magnetic field distribution is very sensitive to the variations of constructional parameters. Construction accuracy greatly influences the magnetic field distribution. Research results obtained here are potentially valuable for future work

  12. Numerical simulation of meteorological conditions for peak pollution in Paris

    Energy Technology Data Exchange (ETDEWEB)

    Carissimo, B. [Electricite de France (EDF), 78 - Chatou (France). Direction des Etudes et Recherches

    1997-06-01

    Results obtained on the simulation of meteorological conditions during two episodes of peak pollution in Paris are presented, one in the winter, the other in the summer. The A3UR air quality modelling system is first described followed by the MERCURE mesoscale meteorological model. The conditions of simulation are described. The results obtained on these two causes show satisfactory agreement, for example on the magnitude of the urban heat island which is correctly reproduced. In this study, several areas of progress have been identified: improvement of the altitude measurement network around cities, the simulation of light wind conditions and the simulation of formation and dissipation of fog. (author) 24 refs.

  13. Kinetic energy storage of off-peak electricity

    International Nuclear Information System (INIS)

    Simpson, L.A.; Oldaker, I.E.; Stermscheg, J.

    1975-09-01

    The concept of using large flywheels to store off-peak electricity has been considered. The development of high strength composite materials has made possible improvements in the energy storage capacity of such devices. The problems involved in designing large flywheels and their economic advantages over alternative means of energy storage are discussed. The economic arguments are based on the present or near future capabilities and costs of structural composite materials. The flywheel costs turn out to be considerably higher than for many alternative schemes including advanced batteries, gas turbine generators and pumped storage schemes. (author)

  14. Ultrafast, ultrahigh-peak power Ti:sapphire laser system

    Energy Technology Data Exchange (ETDEWEB)

    Yamakawa, Koichi; Aoyama, Makoto; Matsuoka, Shinichi; Akahane, Yutaka; Kase, Teiji; Nakano, Fumihiko; Sagisaka, Akito [Advanced Photon Research Center, Kansai Research Establishment, Japan Atomic Energy Research Inst., Kizu, Kyoto (Japan)

    2001-01-01

    We review progress in the generation of multiterawatt optical pulses in the 10-fs range. We describe a design, performance and characterization of a Ti:sapphire laser system based on chirped-pulse amplification, which has produced a peak power in excess of 100-TW with sub-20-fs pulse durations and an average power of 19-W at a 10-Hz repetition rate. We also discuss extension of this system to the petawatt power level and potential applications in the relativistic, ultrahigh intensity regimes. (author)

  15. Transverse Polarization for Energy Calibration at the Z peak

    CERN Document Server

    Koratzinos, M

    2015-01-01

    In this paper we deal with aspects of transverse polarization for the purpose of energy calibration of proposed circular colliders like the FCC-ee and the CEPC. The main issues of such a measurement will be discussed. The possibility of using this method to accurately determine the energy at the WW threshold as well as the Z peak will be addressed. The use of wigglers for reducing long polarization times will be discussed and a possible strategy will be presented for minimising the energy uncertainty error in these large machines.

  16. Power peak in vicinity of WWER-440 control assembly

    International Nuclear Information System (INIS)

    Mikus, J.

    2002-01-01

    This paper presents information concerning the WWER-440 local power peaking problem induced by a control assembly and corresponding investigation possibilities on the light-water zero-power reactor LR-O at the Nuclear Research Institute Rez plc. Brief description of the disposable CA model, experimental arrangement and conditions on the LR-O reactor, preparation of the relevant measurements in the WWER-440 type cores with CA model, as well as some preliminary results of the fission density distribution obtained in a core without boron and with fuel assemblies having profiled enrichment are mentioned too (Author)

  17. FAST MUSIC SPECTRUM PEAK SEARCH VIA METROPOLIS-HASTINGS SAMPLER

    Institute of Scientific and Technical Information of China (English)

    Guo Qinghua; Liao Guisheng

    2005-01-01

    A fast MUltiple SIgnal Classification (MUSIC) spectrum peak search algorithm is devised, which regards the power of the MUSIC spectrum function as target distribution up to a constant of proportionality, and uses Metropolis-Hastings (MH) sampler, one of the most popular Markov Chain Monte Carlo (MCMC) techniques, to sample from it. The proposed method reduces greatly the tremendous computation and storage costs in conventional MUSIC techniques i.e., about two and four orders of magnitude in computation and storage costs under the conditions of the experiment in the paper respectively.

  18. Density-dependent clustering: I. Pulling back the curtains on motions of the BAO peak

    Science.gov (United States)

    Neyrinck, Mark C.; Szapudi, István; McCullagh, Nuala; Szalay, Alexander S.; Falck, Bridget; Wang, Jie

    2018-05-01

    The most common statistic used to analyze large-scale structure surveys is the correlation function, or power spectrum. Here, we show how `slicing' the correlation function on local density brings sensitivity to interesting non-Gaussian features in the large-scale structure, such as the expansion or contraction of baryon acoustic oscillations (BAO) according to the local density. The sliced correlation function measures the large-scale flows that smear out the BAO, instead of just correcting them as reconstruction algorithms do. Thus, we expect the sliced correlation function to be useful in constraining the growth factor, and modified gravity theories that involve the local density. Out of the studied cases, we find that the run of the BAO peak location with density is best revealed when slicing on a ˜40 h-1 Mpc filtered density. But slicing on a ˜100 h-1 Mpc filtered density may be most useful in distinguishing between underdense and overdense regions, whose BAO peaks are separated by a substantial ˜5 h-1 Mpc at z = 0. We also introduce `curtain plots' showing how local densities drive particle motions toward or away from each other over the course of an N-body simulation.

  19. Structural geology of the French Peak accommodation zone, Nevada Test Site, southwestern Nevada

    International Nuclear Information System (INIS)

    Hudson, M.R.

    1997-01-01

    The French Peak accommodation zone (FPAZ) forms an east-trending bedrock structural high in the Nevada Test Site region of southwestern Nevada that formed during Cenozoic Basin and Range extension. The zone separates areas of opposing directions of tilt and downthrow on faults in the Yucca Flat and Frenchman Flat areas. Paleomagnetic data show that rocks within the accommodation zone adjacent to Yucca Flat were not strongly affected by vertical-axis rotation and thus that the transverse strikes of fault and strata formed near their present orientation. Both normal- and oblique strike-slip faulting in the FPAZ largely occurred under a normal-fault stress regime, with least principal stress oriented west-northwest. The normal and sinistral faults in the Puddle Peka segment transfers extension between the Plutonium Valley normal fault zone and the Cane Spring sinistral fault. Recognition of sinistral shear across the Puddle Peak segment allows the Frenchman Flat basin to be interpreted as an asymmetric pull-apart basin developed between the FPAZ and a zone of east-northeast-striking faults to the south that include the Rock Valley fault. The FPAZ has the potential to influence ground-water flow in the region in several ways. Fracture density and thus probably fracture conductivity is high within the FPAZ due to the abundant fault splays present. Moreover,, fractures oriented transversely to the general southward flow of ground water through Yucca Flat area are significant and have potential to laterally divert ground water. Finally, the FPAZ forms a faulted structural high whose northern and southern flanks may permit intermixing of ground waters from different aquifer levels, namely the lower carbonate, welded tuff, and alluvial aquifers. 42 refs

  20. Gas exchange of the ostrich embryo during peak metabolism in ...

    African Journals Online (AJOL)

    Oxygen (O2) consumption and carbon dioxide (CO2) excretion of ostrich embryos were studied on 45 ostrich eggs in various stages of development. A closed respirometry system was used for eggs subjected to ????10 days of incubation, while an open flow system was used for older eggs. A total of 102 measurements ...