WorldWideScience

Sample records for microangiographic fluoroscopic hsmaf

  1. Secure fingerprint identification based on structural and microangiographic optical coherence tomography.

    Science.gov (United States)

    Liu, Xuan; Zaki, Farzana; Wang, Yahui; Huang, Qiongdan; Mei, Xin; Wang, Jiangjun

    2017-03-10

    Optical coherence tomography (OCT) allows noncontact acquisition of fingerprints and hence is a highly promising technology in the field of biometrics. OCT can be used to acquire both structural and microangiographic images of fingerprints. Microangiographic OCT derives its contrast from the blood flow in the vasculature of viable skin tissue, and microangiographic fingerprint imaging is inherently immune to fake fingerprint attack. Therefore, dual-modality (structural and microangiographic) OCT imaging of fingerprints will enable more secure acquisition of biometric data, which has not been investigated before. Our study on fingerprint identification based on structural and microangiographic OCT imaging is, we believe, highly innovative. In this study, we performed OCT imaging study for fingerprint acquisition, and demonstrated the capability of dual-modality OCT imaging for the identification of fake fingerprints.

  2. A theoretical and experimental evaluation of the microangiographic fluoroscope: A high-resolution region-of-interest x-ray imager

    International Nuclear Information System (INIS)

    Jain, Amit; Bednarek, D. R.; Ionita, Ciprian; Rudin, S.

    2011-01-01

    Purpose: The increasing need for better image quality and high spatial resolution for successful endovascular image-guided interventions (EIGIs) and the inherent limitations of the state-of-the-art detectors provide motivation to develop a detector system tailored to the specific, demanding requirements of neurointerventional applications.Method: A microangiographic fluoroscope (MAF) was developed to serve as a high-resolution, region-of-interest (ROI) x-ray imaging detector in conjunction with large lower-resolution full field-of-view (FOV) state-of-the-art x-ray detectors. The newly developed MAF is an indirect x-ray imaging detector capable of providing real-time images (30 frames per second) with high-resolution, high sensitivity, no lag and low instrumentation noise. It consists of a CCD camera coupled to a Gen 2 dual-stage microchannel plate light image intensifier (LII) through a fiber-optic taper. A 300 μm thick CsI(Tl) phosphor serving as the front end is coupled to the LII. The LII is the key component of the MAF and the large variable gain provided by it enables the MAF to operate as a quantum-noise-limited detector for both fluoroscopy and angiography. Results: The linear cascade model was used to predict the theoretical performance of the MAF, and the theoretical prediction showed close agreement with experimental findings. Linear system metrics such as MTF and DQE were used to gauge the detector performance up to 10 cycles/mm. The measured zero frequency DQE(0) was 0.55 for an RQA5 spectrum. A total of 21 stages were identified for the whole imaging chain and each stage was characterized individually. Conclusions: The linear cascade model analysis provides insight into the imaging chain and may be useful for further development of the MAF detector. The preclinical testing of the prototype detector in animal procedures is showing encouraging results and points to the potential for significant impact on EIGIs when used in conjunction with a state

  3. Microangiographic study of the canine dental tissues: a preliminary report

    International Nuclear Information System (INIS)

    Miyabayashi, T.; Morgan, J.P.

    1987-01-01

    A microangiographic study of the dental tissues was performed on one adult mongrel dog to examine the usefulness of the technique. This preliminary study used 30% wt/vol Micropaque suspension which was perfused into the common carotid arteries. After the complete perfusion, the specimen was fixed into a mixture of 10% buffered neutral formalin solution and 95% ethyl alcohol. The mandibular bone with teeth in situ was decalcified. The specimen was embedded in methyl methacrylate. One mm slab sections were made, and then the microangiographs were made. Adequate filling of arterioles was evident on the microangiographs. This technique is shown to be useful in characterizing the nature of the blood supply to the bone and teeth that might be involved in the pathogenesis of radiation-induced injury in the canine dental and periodontal tissues

  4. LabVIEW Graphical User Interface for a New High Sensitivity, High Resolution Micro-Angio-Fluoroscopic and ROI-CBCT System.

    Science.gov (United States)

    Keleshis, C; Ionita, Cn; Yadava, G; Patel, V; Bednarek, Dr; Hoffmann, Kr; Verevkin, A; Rudin, S

    2008-01-01

    A graphical user interface based on LabVIEW software was developed to enable clinical evaluation of a new High-Sensitivity Micro-Angio-Fluoroscopic (HSMAF) system for real-time acquisition, display and rapid frame transfer of high-resolution region-of-interest images. The HSMAF detector consists of a CsI(Tl) phosphor, a light image intensifier (LII), and a fiber-optic taper coupled to a progressive scan, frame-transfer, charged-coupled device (CCD) camera which provides real-time 12 bit, 1k × 1k images capable of greater than 10 lp/mm resolution. Images can be captured in continuous or triggered mode, and the camera can be programmed by a computer using Camera Link serial communication. A graphical user interface was developed to control the camera modes such as gain and pixel binning as well as to acquire, store, display, and process the images. The program, written in LabVIEW, has the following capabilities: camera initialization, synchronized image acquisition with the x-ray pulses, roadmap and digital subtraction angiography acquisition (DSA), flat field correction, brightness and contrast control, last frame hold in fluoroscopy, looped playback of the acquired images in angiography, recursive temporal filtering and LII gain control. Frame rates can be up to 30 fps in full-resolution mode. The user friendly implementation of the interface along with the high framerate acquisition and display for this unique high-resolution detector should provide angiographers and interventionalists with a new capability for visualizing details of small vessels and endovascular devices such as stents and hence enable more accurate diagnoses and image guided interventions. (Support: NIH Grants R01NS43924, R01EB002873).

  5. Quantitative comparison using Generalized Relative Object Detectability (G-ROD) metrics of an amorphous selenium detector with high resolution Microangiographic Fluoroscopes (MAF) and standard flat panel detectors (FPD).

    Science.gov (United States)

    Russ, M; Shankar, A; Jain, A; Setlur Nagesh, S V; Ionita, C N; Scott, C; Karim, K S; Bednarek, D R; Rudin, S

    2016-02-27

    A novel amorphous selenium (a-Se) direct detector with CMOS readout has been designed, and relative detector performance investigated. The detector features include a 25 μ m pixel pitch, and 1000 μ m thick a-Se layer operating at 10V/ μ m bias field. A simulated detector DQE was determined, and used in comparative calculations of the Relative Object Detectability (ROD) family of prewhitening matched-filter (PWMF) observer and non-prewhitening matched filter (NPWMF) observer model metrics to gauge a-Se detector performance against existing high resolution micro-angiographic fluoroscopic (MAF) detectors and a standard flat panel detector (FPD). The PWMF-ROD or ROD metric compares two x-ray imaging detectors in their relative abilities in imaging a given object by taking the integral over spatial frequencies of the Fourier transform of the detector DQE weighted by an object function, divided by the comparable integral for a different detector. The generalized-ROD (G-ROD) metric incorporates clinically relevant parameters (focal-spot size, magnification, and scatter) to show the degradation in imaging performance for detectors that are part of an imaging chain. Preliminary ROD calculations using simulated spheres as the object predicted superior imaging performance by the a-Se detector as compared to existing detectors. New PWMF-G-ROD and NPWMF-G-ROD results still indicate better performance by the a-Se detector in an imaging chain over all sphere sizes for various focal spot sizes and magnifications, although a-Se performance advantages were degraded by focal spot blurring. Nevertheless, the a-Se technology has great potential to provide breakthrough abilities such as visualization of fine details including of neuro-vascular perforator vessels and of small vascular devices.

  6. Macro- and microangiographic picture of two cases of the liver primary carcinoma

    International Nuclear Information System (INIS)

    Gregorczyk, A.

    1984-01-01

    The paper presents the most important features of the macro- and microangiographic picture of the liver primary carcinomata. Arterial ramifications of the liver were injected with a contrast medium - Micropaque, the liver was cut into 0.5 cm thick slices in the vertical and horizontal plane. The angiograms revealed radiological pictures of macroscopic arterial vascularization of the liver. In order to make a microangiographic estimation, the author cut the cubes about 20 x 20 x 5 mm in sizes out of 0.5 cm thick slices. The cubes were cut frozen in a microtome into sections of a thickness 1500 μ. Microangiographic pictures were taken and assessed in 8 x magnification. According to the author, the obtained results present a great cognitive importance and will help in better assessment of angiograms performed in patients with liver carcinomata. (orig.) [de

  7. SU-E-I-53: Comparison of Kerma-Area-Product Between the Micro-Angiographic Fluoroscope (MAF) and a Flat Panel Detector (FPD) as Used in Neuro-Endovascular Procedures

    International Nuclear Information System (INIS)

    Vijayan, S; Rana, V; Nagesh, S Setlur; Xiong, Z; Rudin, S; Bednarek, D

    2015-01-01

    Purpose: To determine the reduction of integral dose to the patient when using the micro-angiographic fluoroscope (MAF) compared to when using the standard flat-panel detector (FPD) for the techniques used during neurointerventional procedures. Methods: The MAF is a small field-of-view, high resolution x-ray detector which captures 1024 x 1024 pixels with an effective pixel size of 35μm and is capable of real-time imaging up to 30 frames per second. The MAF was used in neuro-interventions during those parts of the procedure when high resolution was needed and the FPD was used otherwise. The technique parameters were recorded when each detector was used and the kerma-area-product (KAP) per image frame was determined. KAP values were calculated for seven neuro interventions using premeasured calibration files of output as a function of kVp and beam filtration and included the attenuation of the patient table for the frontal projections to be more representative of integral patient dose. The air kerma at the patient entrance was multiplied by the beam area at that point to obtain the KAP values. The ranges of KAP values per frame were determined for the range of technique parameters used during the clinical procedures. To appreciate the benefit of the higher MAF resolution in the region of interventional activity, DA technique parameters were generally used with the MAF. Results: The lowest and highest values of KAP per frame for the MAF in DA mode were 4 and 50 times lower, respectively, compared to those of the FPD in pulsed fluoroscopy mode. Conclusion: The MAF was used in those parts of the clinical procedures when high resolution and image quality was essential. The integral patient dose as represented by the KAP value was substantially lower when using the MAF than when using the FPD due to the much smaller volume of tissue irradiated. This research was supported in part by Toshiba Medical Systems Corporation and NIH Grant R01EB002873

  8. SU-E-I-53: Comparison of Kerma-Area-Product Between the Micro-Angiographic Fluoroscope (MAF) and a Flat Panel Detector (FPD) as Used in Neuro-Endovascular Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Vijayan, S; Rana, V; Nagesh, S Setlur; Xiong, Z; Rudin, S; Bednarek, D [Toshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY (United States)

    2015-06-15

    Purpose: To determine the reduction of integral dose to the patient when using the micro-angiographic fluoroscope (MAF) compared to when using the standard flat-panel detector (FPD) for the techniques used during neurointerventional procedures. Methods: The MAF is a small field-of-view, high resolution x-ray detector which captures 1024 x 1024 pixels with an effective pixel size of 35μm and is capable of real-time imaging up to 30 frames per second. The MAF was used in neuro-interventions during those parts of the procedure when high resolution was needed and the FPD was used otherwise. The technique parameters were recorded when each detector was used and the kerma-area-product (KAP) per image frame was determined. KAP values were calculated for seven neuro interventions using premeasured calibration files of output as a function of kVp and beam filtration and included the attenuation of the patient table for the frontal projections to be more representative of integral patient dose. The air kerma at the patient entrance was multiplied by the beam area at that point to obtain the KAP values. The ranges of KAP values per frame were determined for the range of technique parameters used during the clinical procedures. To appreciate the benefit of the higher MAF resolution in the region of interventional activity, DA technique parameters were generally used with the MAF. Results: The lowest and highest values of KAP per frame for the MAF in DA mode were 4 and 50 times lower, respectively, compared to those of the FPD in pulsed fluoroscopy mode. Conclusion: The MAF was used in those parts of the clinical procedures when high resolution and image quality was essential. The integral patient dose as represented by the KAP value was substantially lower when using the MAF than when using the FPD due to the much smaller volume of tissue irradiated. This research was supported in part by Toshiba Medical Systems Corporation and NIH Grant R01EB002873.

  9. WE-G-204-05: Relative Object Detectability Evaluation of a New High Resolution A-Se Direct Detection System Compared to Indirect Micro-Angiographic Fluoroscopic (MAF) Detectors

    International Nuclear Information System (INIS)

    Russ, M; Nagesh, S Setlur; Ionita, C; Bednarek, D; Rudin, S; Scott, C; Karim, K

    2015-01-01

    Purpose: To evaluate the task specific imaging performance of a new 25µm pixel pitch, 1000µm thick amorphous selenium direct detection system with CMOS readout for typical angiographic exposure parameters using the relative object detectability (ROD) metric. Methods: The ROD metric uses a simulated object function weighted at each spatial frequency by the detectors’ detective quantum efficiency (DQE), which is an intrinsic performance metric. For this study, the simulated objects were aluminum spheres of varying diameter (0.05–0.6mm). The weighted object function is then integrated over the full range of detectable frequencies inherent to each detector, and a ratio is taken of the resulting value for two detectors. The DQE for the 25µm detector was obtained from a simulation of a proposed a-Se detector using an exposure of 200µR for a 50keV x-ray beam. This a-Se detector was compared to two microangiographic fluoroscope (MAF) detectors [the MAF-CCD with pixel size of 35µm and Nyquist frequency of 14.2 cycles/mm and the MAF-CMOS with pixel size of 75µm and Nyquist frequency of 6.6 cycles/mm] and a standard flat-panel detector (FPD with pixel size of 194µm and Nyquist frequency of 2.5cycles/mm). Results: ROD calculations indicated vastly superior performance by the a-Se detector in imaging small aluminum spheres. For the 50µm diameter sphere, the ROD values for the a-Se detector compared to the MAF-CCD, the MAF-CMOS, and the FPD were 7.3, 9.3 and 58, respectively. Detector performance in the low frequency regime was dictated by each detector’s DQE(0) value. Conclusion: The a-Se with CMOS readout is unique and appears to have distinctive advantages of incomparable high resolution, low noise, no readout lag, and expandable design. The a-Se direct detection system will be a powerful imaging tool in angiography, with potential break-through applications in diagnosis and treatment of neuro-vascular disease. Supported by NIH Grant: 2R01EB002873 and an

  10. WE-G-204-05: Relative Object Detectability Evaluation of a New High Resolution A-Se Direct Detection System Compared to Indirect Micro-Angiographic Fluoroscopic (MAF) Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Russ, M; Nagesh, S Setlur; Ionita, C; Bednarek, D; Rudin, S [Toshiba Stroke and Vascular Research Center, University at Buffalo (SUNY), Buffalo, NY (United States); Scott, C; Karim, K [University of Waterloo, Waterloo, ON (Canada)

    2015-06-15

    Purpose: To evaluate the task specific imaging performance of a new 25µm pixel pitch, 1000µm thick amorphous selenium direct detection system with CMOS readout for typical angiographic exposure parameters using the relative object detectability (ROD) metric. Methods: The ROD metric uses a simulated object function weighted at each spatial frequency by the detectors’ detective quantum efficiency (DQE), which is an intrinsic performance metric. For this study, the simulated objects were aluminum spheres of varying diameter (0.05–0.6mm). The weighted object function is then integrated over the full range of detectable frequencies inherent to each detector, and a ratio is taken of the resulting value for two detectors. The DQE for the 25µm detector was obtained from a simulation of a proposed a-Se detector using an exposure of 200µR for a 50keV x-ray beam. This a-Se detector was compared to two microangiographic fluoroscope (MAF) detectors [the MAF-CCD with pixel size of 35µm and Nyquist frequency of 14.2 cycles/mm and the MAF-CMOS with pixel size of 75µm and Nyquist frequency of 6.6 cycles/mm] and a standard flat-panel detector (FPD with pixel size of 194µm and Nyquist frequency of 2.5cycles/mm). Results: ROD calculations indicated vastly superior performance by the a-Se detector in imaging small aluminum spheres. For the 50µm diameter sphere, the ROD values for the a-Se detector compared to the MAF-CCD, the MAF-CMOS, and the FPD were 7.3, 9.3 and 58, respectively. Detector performance in the low frequency regime was dictated by each detector’s DQE(0) value. Conclusion: The a-Se with CMOS readout is unique and appears to have distinctive advantages of incomparable high resolution, low noise, no readout lag, and expandable design. The a-Se direct detection system will be a powerful imaging tool in angiography, with potential break-through applications in diagnosis and treatment of neuro-vascular disease. Supported by NIH Grant: 2R01EB002873 and an

  11. Design considerations for a new, high resolution Micro-Angiographic Fluoroscope based on a CMOS sensor (MAF-CMOS).

    Science.gov (United States)

    Loughran, Brendan; Swetadri Vasan, S N; Singh, Vivek; Ionita, Ciprian N; Jain, Amit; Bednarek, Daniel R; Titus, Albert; Rudin, Stephen

    2013-03-06

    The detectors that are used for endovascular image-guided interventions (EIGI), particularly for neurovascular interventions, do not provide clinicians with adequate visualization to ensure the best possible treatment outcomes. Developing an improved x-ray imaging detector requires the determination of estimated clinical x-ray entrance exposures to the detector. The range of exposures to the detector in clinical studies was found for the three modes of operation: fluoroscopic mode, high frame-rate digital angiographic mode (HD fluoroscopic mode), and DSA mode. Using these estimated detector exposure ranges and available CMOS detector technical specifications, design requirements were developed to pursue a quantum limited, high resolution, dynamic x-ray detector based on a CMOS sensor with 50 μm pixel size. For the proposed MAF-CMOS, the estimated charge collected within the full exposure range was found to be within the estimated full well capacity of the pixels. Expected instrumentation noise for the proposed detector was estimated to be 50-1,300 electrons. Adding a gain stage such as a light image intensifier would minimize the effect of the estimated instrumentation noise on total image noise but may not be necessary to ensure quantum limited detector operation at low exposure levels. A recursive temporal filter may decrease the effective total noise by 2 to 3 times, allowing for the improved signal to noise ratios at the lowest estimated exposures despite consequent loss in temporal resolution. This work can serve as a guide for further development of dynamic x-ray imaging prototypes or improvements for existing dynamic x-ray imaging systems.

  12. An experimental microangiographic study on injured liver acinus by ligation of common bile duct

    International Nuclear Information System (INIS)

    Park, Jong Yeon; Kim, Yoon Gyu; Moon, Ki Ho; Lee, Suek Hong; Kim, Byung Soo; Han, Gun Taik

    1994-01-01

    The purpose of this study was to evaluate the morphologic changes of the injured hepatic acini following ligation of common bile duct and to investigate the pathophysiologic process of hepatic failure and biliary liver cirrhosis in the extrahepatic cholestasis. The common bile ducts of 18 rabbits were ligated partially. The rabbits were killed and selective microangiography was carried out with infusion of barium suspensio via portal vein 4 to 24 weeks after ligation. Selective microangiography was also carried out in two normal rabbits. The microangiographic findings were evaluated and correlated with histopathologic features. The sinusoids of the liver acinus showed distortion, varying degrees of luminal widening, and irregularities in architecture. Terminal branches of the portal vein (TPV) showed increased number of branches, luminal narrowing, tortuosity, distortion, and beaded appearance. Peribiliary plexi were found as thin curvilinear, barium-filled structures along the wall of the dilated bile duct. The microangiographic findings were well correlated with histopathologic findings. The grades of microangiographic and histopathologic findings were poorly correlated with the duration of the ligation of CBD. Changes in microvasculature of the liver scinus following partial ligation of common bile duct were demonstrated by microangiography. Although the microvascular changes were evoked secondary to the injury, they might have some active roles in the pathophysiologic process in the liver

  13. Evaluation and Comparison of High-Resolution (HR) and High-Light (HL) Phosphors in the Micro-Angiographic Fluoroscope (MAF) using Generalized Linear Systems Analyses (GMTF, GDQE) that include the Effect of Scatter, Magnification and Detector Characteristics.

    Science.gov (United States)

    Gupta, Sandesh K; Jain, Amit; Bednarek, Daniel R; Rudin, Stephen

    2011-01-01

    In this study, we evaluated the imaging characteristics of the high-resolution, high-sensitivity micro-angiographic fluoroscope (MAF) with 35-micron pixel-pitch when used with different commercially-available 300 micron thick phosphors: the high resolution (HR) and high light (HL) from Hamamatsu. The purpose of this evaluation was to see if the HL phosphor with its higher screen efficiency could be replaced with the HR phosphor to achieve improved resolution without an increase in noise resulting from the HR's decreased light-photon yield. We designated the detectors MAF-HR and MAF-HL and compared them with a standard flat panel detector (FPD) (194 micron pixel pitch and 600 micron thick CsI(Tl)). For this comparison, we used the generalized linear-system metrics of GMTF, GNNPS and GDQE which are more realistic measures of total system performance since they include the effect of scattered radiation, focal spot distribution, and geometric un-sharpness. Magnifications (1.05-1.15) and scatter fractions (0.28 and 0.33) characteristic of a standard head phantom were used. The MAF-HR performed significantly better than the MAF-HL at high spatial frequencies. The ratio of GMTF and GDQE of the MAF-HR compared to the MAF-HL at 3(6) cycles/mm was 1.45(2.42) and 1.23(2.89), respectively. Despite significant degradation by inclusion of scatter and object magnification, both MAF-HR and MAF-HL provide superior performance over the FPD at higher spatial frequencies with similar performance up to the FPD's Nyquist frequency of 2.5 cycles/mm. Both substantially higher resolution and improved GDQE can be achieved with the MAF using the HR phosphor instead of the HL phosphor.

  14. Micro-angiographic system using synchrotron radiation and conventional x-ray source for visualizing angiogenic vessels induced by cardiovascular regeneration therapy

    International Nuclear Information System (INIS)

    Mori, H.; Chiku, M.; Nishigami, K.; Tanaka, E.; Kimura, K.; Kawai, T.; Suzuki, K.; Mochizuki, R.; Okawa, Y.

    2004-01-01

    Therapeutic angiogenesis improved critical limb and myocardial ischemia in human, however, angiogenic vessels were not visualized well by conventional angiography, because of its limited spatial resolution of 200 μm. Recently, synchrotron radiation system characterized by high brightness, monochromatic and collimated nature revealed the micro-vessels of heart and lower limb in situ. We developed also an in-house microangiographic system with a relatively low cost. Limb ischemia models were made by ligature of femoral artery and treated by angiogenic growth factor genes and so on. One month after the treatment, we evaluated collateral micro-vessels by using the conventional and micro-angiographic systems. The approach was left femoral artery, and catheter was located in abdominal aorta. Iodine contrast (300 mg/ml) was injected 5 ml by 3 ml/sec with auto-injection system. The imaging was recorded by digital source in 1000 x 1000 pixels. The micro-angiographic system could detect the micro-vessels more precisely than conventional angiographic system and evaluate their function. (author)

  15. Microangiographic study of the normal anatomy of the cerebral venous system in rats

    International Nuclear Information System (INIS)

    Schumacher, M.

    1984-01-01

    Microangiographic serial cuts were performed in 20 Sprague-Dawley rats for a systematic study of the normal anatomy of the cerebral veins. The draining pathways of the cerebral and cerebellar cortex, basal ganglia, hypothalamus, hippocampus and the midbrain are described and discussed with regard to their different functions. (orig.)

  16. Experimental microangiographic study in normal rabbit liver

    International Nuclear Information System (INIS)

    Kim, Yoon Gyoo; Park, Jong Yeon; Han, Kook Sang; Moon, Ki Ho; Choi, Chang Ho; Han, Koon Taek; Lee, Suck Hong; Kim, Byung Soo

    1994-01-01

    Microangiography is an experimental radiologic technique for evaluation of the morphology and the function of small vessels. The purpose of this study is to introduce a good microangiographic technique and to present the microangiographic appearance of normal hepatic vascular pattern. Five white rabbits weighing 2.5-2.9Kg were objected. Polyethylene catheters were inserted in portal vein and then in IVC. Heparin mixed normal saline (2cc/1000cc) was infused through portal vein and blood was drained to IVC. Barium suspension was infused via the catheter placed in portal vein until the liver surface showed satisfactory finding in barium filling. The liver was removed and this preparation was fixed in 10% formaline for 7 days. After fixation, the liver was sectioned on 1-2mm thickness. The slices were radiographed on high resolution plate using Faxitron. H-E staining of liver tissue was also done. The microbrium was well distributed in all small vessels without filling defect. And we could find the hexagonal shaped classic liver lobule, in which the central vein was located at central portion and portal vein at periphery. The enlargement was showed numerous sinusoids, but there was less dye in the central portion of lobule, but the central vein was well filled by microbarium. The peripheral portion of lobule was well filled with microbarium. So, we could find diamond shaped liver acinus, in which central vein was located at priperal portion and the center of liver acinus was terminal portal vein that growed out from a small portal space. The three acini made the complex acinus and acinar agglomerate was composed of three or four complex acini. It is considered that the liver acinus pattern of Rapparport is more acceptable on microangiography than the classic concept of hepatic lobule

  17. Fluoroscopic digital radiography

    International Nuclear Information System (INIS)

    Hynes, D.M.; Rowlands, J.A.; Edmonds, E.W.; Porter, A.J.; Toth, B.D.

    1987-01-01

    The authors have been working with three different developmental systems, exploring the clinical benefits of digital recording of the fluoroscopic image. This educational exhibit describes the components of such systems and emphasizes the strengths and weaknesses of each. Specific technical reference is made to the image intensifier, TV camera, 1,024/sup 2/ image store, hard copy devices, and the mechanics of operation in the general fluoroscopic environment. All observations indicate that the problems of resolution, motion blur, noise, field size, and dose can be solved. The findings are supported by clinical examples

  18. 21 CFR 892.1650 - Image-intensified fluoroscopic x-ray system.

    Science.gov (United States)

    2010-04-01

    ... fluoroscopic x-ray system. (a) Identification. An image-intensified fluoroscopic x-ray system is a device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Image-intensified fluoroscopic x-ray system. 892... equipment, patient and equipment supports, component parts, and accessories. (b) Classification. Class II...

  19. Comparing radiation exposure during percutaneous vertebroplasty using one- vs. two-fluoroscopic technique

    Directory of Open Access Journals (Sweden)

    Li Yen-Yao

    2013-01-01

    Full Text Available Abstract Background Percutaneous vertebroplasty (PV requires relatively lengthy fluoroscopic guidance, which might lead to substantial radiation exposure to patients or operators. The two-fluoroscopic technique (two-plane radiographs obtained using two fluoroscopes during PV can provide simultaneous two-planar projections with reducing operative time. However, the two-fluoroscopic technique may expose the operator or patient to increased radiation dose. The aim of this study was to quantify the amount of radiation exposure to the patient or operator that occurs during PV using one- vs. two-fluoroscopic technique. Methods Two radiation dosimeters were placed on the right flank of each patient and on the upper sternum of each operator during 26 single-level PV procedures by one senior surgeon. The use of two-fluoroscopic technique (13 patients and one-fluoroscopic technique (13 patients were allocated in a consecutive and alternative manner. The operative time and mean radiation dose to each patient and operator were monitored and compared between groups. Results Mean radiation dose to the patient was 1.97 ± 1.20 mSv (95% CI, 0.71 to 3.23 for the one-fluoroscopic technique group vs. 0.95 ± 0.34 mSv (95% CI, 0.85 to 1.23 for the two-fluoroscopic technique group (P =0.031. Mean radiation dose to the operator was 0.27 ± 0.12 mSv (95% CI, 0.17–0.56 for the one-fluoroscopic technique group vs. 0.25 ± 0.14 mSv (95% CI, 0.06–0.44 for the two-fluoroscopic technique group (P = 0.653. The operative time was significantly different between groups: 47.15 ± 13.48 min (range, 20–75 for the one-fluoroscopic technique group vs. 36.62 ± 8.42 min (range, 21–50 for the two-fluoroscopic technique group (P =0.019. Conclusion Compared to the one-fluoroscopic technique, the two-fluoroscopic technique used during PV provides not only shorter operative times but also reduces the radiation exposure to the patient. There was no

  20. 21 CFR 892.1660 - Non-image-intensified fluoroscopic x-ray system.

    Science.gov (United States)

    2010-04-01

    ... fluoroscopic x-ray system. (a) Identification. A non-image-intensified fluoroscopic x-ray system is a device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Non-image-intensified fluoroscopic x-ray system... display equipment, patient and equipment supports, component parts, and accessories. (b) Classification...

  1. Quality assurance in diagnostic radiology - assessing the fluoroscopic image quality

    International Nuclear Information System (INIS)

    Tabakov, S.

    1995-01-01

    The X-ray fluoroscopic image has a considerably lower resolution than the radiographic one. This requires a careful quality control aiming at optimal use of the fluoroscopic equipment. The basic procedures for image quality assessment of Image Intensifier/TV image are described. Test objects from Leeds University (UK) are used as prototypes. The results from examining 50 various fluoroscopic devices are shown. Their limiting spatial resolution varies between 0.8 lp/mm (at maximum II field size) and 2.24 lp/mm (at minimum field size). The mean value of the limiting spatial resolution for a 23 cm Image Intensifier is about 1.24 lp/mm. The mean limits of variation of the contrast/detail diagram for various fluoroscopic equipment are graphically expressed. 14 refs., 1 fig. (author)

  2. Pre-procedural scout radiographs are unnecessary for routine pediatric fluoroscopic examinations

    Energy Technology Data Exchange (ETDEWEB)

    Creeden, Sean G.; Rao, Anil G.; Eklund, Meryle J.; Hill, Jeanne G.; Thacker, Paul G. [Medical University of South Carolina, Department of Radiology and Radiological Science, Charleston, SC (United States)

    2017-03-15

    Although practice patterns vary, scout radiographs are often routinely performed with pediatric fluoroscopic studies. However few studies have evaluated their utility in routine pediatric fluoroscopy. To evaluate the value of scout abdomen radiographs in routine barium or water-soluble enema, upper gastrointestinal (GI) series, and voiding cystourethrogram pediatric fluoroscopic procedures. We retrospectively evaluated 723 barium or water-soluble enema, upper GI series, and voiding cystourethrogram fluoroscopic procedures performed at our institution. We assessed patient history and demographics, clinical indication for the examination, prior imaging findings and impressions, scout radiograph findings, additional findings provided by the scout radiograph that were previously unknown, and whether the scout radiograph contributed any findings that significantly changed management. We retrospectively evaluated 723 fluoroscopic studies (368 males and 355 females) in pediatric patients. Of these, 700 (96.8%) had a preliminary scout radiograph. Twenty-three (3.2%) had a same-day radiograph substituted as a scout radiograph. Preliminary scout abdomen radiographs/same-day radiographs showed no new significant findings in 719 (99.4%) studies. New but clinically insignificant findings were seen in 4 (0.6%) studies and included umbilical hernia, inguinal hernia and hip dysplasia. No findings were found on the scout radiographs that would either alter the examination performed or change management with regard to the exam. Pre-procedural scout abdomen radiographs are unnecessary in routine barium and water-soluble enema, upper GI series, and voiding cystourethrogram pediatric fluoroscopic procedures and can be substituted with a spot fluoroscopic last-image hold. (orig.)

  3. A rapid method of evaluating fluoroscopic system performance

    International Nuclear Information System (INIS)

    Sprawls, P.

    1989-01-01

    This paper presents a study to develop a method for the rapid evaluation and documentation of fluoroscopic image quality. All objects contained within a conventional contrast-detail test phantom (Leeds TO-10) are displayed in an array format according to their contrast and size. A copy of the display is used as the data collection form and a permanent record of system performance. A fluoroscope is evaluated by viewing the test phantom and marking the visible objects on the display. A line drawn through the objects with minimum visibility in each size group forms a contrast-detail curve for the system. This is compared with a standard or reference line, which is in the display.Deviations in curve position are useful indicators of specific image quality problems, such as excessive noise or blurring. The use of a special object-visibility array format display makes it possible to collect data, analyze the results, and create a record of fluoroscopic performance in less than 2 minutes for each viewing mode

  4. Fluoroscopic Imaging Systems. Chapter 8

    Energy Technology Data Exchange (ETDEWEB)

    Jones, A. K. [University of Texas MD Anderson Cancer Center, Houston (United States)

    2014-09-15

    Fluoroscopy refers to the use of an X ray beam and a suitable image receptor for viewing images of processes or instruments in the body in real time. Fluoroscopic imaging trades the high signal to noise ratio (SNR) of radiography for high temporal resolution, as factors that maintain patient dose at an acceptable level must be used.

  5. Objective masurement of image quality in fluoroscopic x-ray equipment FluoroQuality

    CERN Document Server

    Tapiovaara, M

    2003-01-01

    The report describes FluoroQuality, a computer program that is developed in STUK and used for measuring the image quality in medical fluoroscopic equipment. The method is based on the statistical decision theory (SDT) and the main measurement result is given in terms of the accumulation rate of the signal-to-noise ratio squared (SNR sup 2 sub r sub a sub t sub e). In addition to this quantity several other quantities are measured. These quantities include the SNR of single image frames, the spatio-temporal noise power spectrum and the temporal lag. The measurement method can be used, for example, for specifying the image quality in fluoroscopic images, for optimising the image quality and dose rate in fluoroscopy and for quality control of fluoroscopic equipment. The theory behind the measurement method is reviewed and the measurement of the various quantities is explained. An example of using the method for optimising a specified fluoroscopic procedure is given. The User's Manual of the program is included a...

  6. Clinical application of transnasal feeding tube placement under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Ge Kunyuan; Ni Caifang; Liu Yizhi; Zhu Xiaoli; Zou Jianwei; Jin Yonghai; Chen Long; Sun Ge; Sun Lingfang; Zhang Dong

    2008-01-01

    Objective: To evaluate the feasibility and effectiveness of duodenal feeding tube placement under fluoroscopic guidance and its clinical application. Methods: The transnasal duodenal nutriment tubes placement under fluoroscopic guidance were performed in 59 patients from June 3th, 2003 to August 17th, 2007. The successful placement of the feeding tube was defined as that of the tube tip was fixed at or distal to the duodenojejunal junction. Results: 57 out of 59 patients were successfully managed by feeding tube placement, with primary successful rate of 96.6% (57/59). The remaining two failures were due to overdistention of the stomach and were further managed after gastrointestinal decompression thoroughly. The mean fluoroscopy time of the procedure was 17.8 minutes with no severe immediate or delayed complications. Conclusion: The transnasal duodenal nutrient feeding tube placement under fluoroscopic guidance is a safe,economic, and effective management for enteral nutrition, providing extensive clinical utilization. (authors)

  7. Reducing radiation exposure in an electrophysiology lab with introduction of newer fluoroscopic technology

    Directory of Open Access Journals (Sweden)

    Munish Sharma

    2017-09-01

    Full Text Available The use of fluoroscopic devices exposes patients and operators to harmful effects of ionizing radiation in an electrophysiology (EP lab. We sought to know if the newer fluoroscopic technology (Allura Clarity installed in a hybrid EP helps to reduce prescribed radiation dose. We performed radiation dose analysis of 90 patients who underwent various procedures in the EP lab at a community teaching hospital after the introduction of newer fluoroscopic technology in June of 2016.Watchman device insertion, radiofrequency ablation procedures, permanent pacemaker (PPM/implantable cardioverter defibrillator (ICD placement and battery changes were included in the study to compare radiation exposure during different procedures performed commonly in an EP lab. In all cases of watchman device placement, radiofrequency ablation procedures, PPM/ICD placement and battery changes, there was a statistically significant difference (<0.05 in radiation dose exposure. Significant reduction in radiation exposure during various procedures performed in an EP lab was achieved with aid of newer fluoroscopic technology and better image detection technology.

  8. New Jersey's Thomas Edison and the fluoroscope.

    Science.gov (United States)

    Tselos, G D

    1995-11-01

    Thomas Edison played a major role in the development of early x-ray technology in 1896, notably increasing tube power and reliability and making the fluoroscope a practical instrument. Eventually, Edison would move x-ray technology from the laboratory to the marketplace.

  9. Radiation exposure from shoe-fitting fluoroscopes

    International Nuclear Information System (INIS)

    Busch, Uwe

    2015-01-01

    It is 40 years ago that a very popular X-ray device disappeared in German shoe shops: the shoe-fitting fluoroscope or Pedoskop. Since the 1930s, these X-ray machines were an integral part of any good shoe business. Following the entry into force X-Ray Regulation (RoeV 1973) the use of these devices was prohibited in Germany.

  10. Technique of Peritoneal Catheter Placement under Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Abdel-Aal, A.K.; Gaddikeri, S.; Saddekni, S.

    2011-01-01

    Peritoneal catheters are mainly used for peritoneal dialysis in patients with end-stage renal disease. Other uses of this catheter include intraperitoneal chemotherapy and gene therapy for ovarian cancer and draining of uncontrolled refractory ascites in patients with liver cirrhosis. Traditionally, surgeons place most of these peritoneal catheters either by laparoscopy or open laparotomy. We detail our percutaneous approach to placing peritoneal catheters using fluoroscopic guidance. We emphasize the use of additional ultrasound guidance, including gray scale and color Doppler ultrasound, to determine the safest puncture site and to guide the initial needle puncture in order to avoid bowel perforation and injury to epigastric artery. We present our experience in placing peritoneal catheters using this technique in 95 patients with various indications. Fluoroscopic guided percutaneous placement of peritoneal catheters is a safe, minimally invasive, and effective alternative to open surgical or laparoscopic placement.

  11. Fluoroscopic screen which is optically homogeneous

    International Nuclear Information System (INIS)

    1975-01-01

    A high efficiency fluoroscopic screen for X-ray examination consists of an optically homogeneous crystal plate of fluorescent material such as activated cesium iodide, supported on a transparent protective plate, with the edges of the assembly beveled and optically coupled to a light absorbing compound. The product is dressed to the desired thickness and provided with an X-ray-transparent light-opaque cover. (Auth.)

  12. Fluoroscopic guidance for placing a double lumen endotracheal tube in adults.

    Science.gov (United States)

    Calenda, Emile; Baste, Jean Marc; Hajjej, Ridha; Rezig, Najiba; Moriceau, Jerome; Diallo, Yaya; Sghaeir, Slim; Danielou, Eric; Peillon, Christophe

    2014-09-01

    The aim of this study was to assess the right placement of the double lumen endotracheal tube with fluoroscopic guidance, which is used in first intention prior to the fiberscope in our institution. This was a prospective observational study. The study was conducted in vascular and thoracic operating rooms. We enrolled 205 patients scheduled for thoracic surgery, with ASA physical statuses of I (n = 37), II (n = 84), III (n = 80), and IV (n = 4). Thoracic procedures were biopsy (n = 20), wedge (n = 34), culminectomy (n = 6), lobectomy (n = 82), pneumonectomy (n = 4), sympathectomy (n = 9), symphysis (n = 47), and thymectomy (n = 3). The intubation with a double lumen tube was performed with the help of a laryngoscope. Tracheal and bronchial balloons were inflated and auscultation was performed after right and left exclusions. One shot was performed to locate the position of the bronchial tube and the hook. Fluoroscopic guidance was used to relocate the tube in case of a wrong position. When the fluoroscopic guidance failed to position the tube, a fiberscope was used. Perioperative collapse of the lung was assessed by the surgeon during the surgery. Correct fluoroscopic image was obtained after the first attempt in 58.5% of patients therefore a misplaced position was encountered in 41.5%. The fluoroscopic guidance allowed an exact repositioning in 99.5% of cases, and the mean duration of the procedure was 8 minutes. A fiberscope was required to move the hook for one patient. We did not notice a moving of the double lumen endotracheal tube during the surgery. The surgeon satisfaction was 100%. The fluoroscopy evidenced the right position of the double lumen tube and allowed a right repositioning in 99.5% of patients with a very simple implementation. Copyright © 2014. Published by Elsevier B.V.

  13. 3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models

    International Nuclear Information System (INIS)

    Dhou, S; Hurwitz, M; Cai, W; Rottmann, J; Williams, C; Wagar, M; Berbeco, R; Lewis, J H; Mishra, P; Li, R; Ionascu, D

    2015-01-01

    3D fluoroscopic images represent volumetric patient anatomy during treatment with high spatial and temporal resolution. 3D fluoroscopic images estimated using motion models built using 4DCT images, taken days or weeks prior to treatment, do not reliably represent patient anatomy during treatment. In this study we developed and performed initial evaluation of techniques to develop patient-specific motion models from 4D cone-beam CT (4DCBCT) images, taken immediately before treatment, and used these models to estimate 3D fluoroscopic images based on 2D kV projections captured during treatment. We evaluate the accuracy of 3D fluoroscopic images by comparison to ground truth digital and physical phantom images. The performance of 4DCBCT-based and 4DCT-based motion models are compared in simulated clinical situations representing tumor baseline shift or initial patient positioning errors. The results of this study demonstrate the ability for 4DCBCT imaging to generate motion models that can account for changes that cannot be accounted for with 4DCT-based motion models. When simulating tumor baseline shift and patient positioning errors of up to 5 mm, the average tumor localization error and the 95th percentile error in six datasets were 1.20 and 2.2 mm, respectively, for 4DCBCT-based motion models. 4DCT-based motion models applied to the same six datasets resulted in average tumor localization error and the 95th percentile error of 4.18 and 5.4 mm, respectively. Analysis of voxel-wise intensity differences was also conducted for all experiments. In summary, this study demonstrates the feasibility of 4DCBCT-based 3D fluoroscopic image generation in digital and physical phantoms and shows the potential advantage of 4DCBCT-based 3D fluoroscopic image estimation when there are changes in anatomy between the time of 4DCT imaging and the time of treatment delivery. (paper)

  14. Edge enhancement algorithm for low-dose X-ray fluoroscopic imaging.

    Science.gov (United States)

    Lee, Min Seok; Park, Chul Hee; Kang, Moon Gi

    2017-12-01

    Low-dose X-ray fluoroscopy has continually evolved to reduce radiation risk to patients during clinical diagnosis and surgery. However, the reduction in dose exposure causes quality degradation of the acquired images. In general, an X-ray device has a time-average pre-processor to remove the generated quantum noise. However, this pre-processor causes blurring and artifacts within the moving edge regions, and noise remains in the image. During high-pass filtering (HPF) to enhance edge detail, this noise in the image is amplified. In this study, a 2D edge enhancement algorithm comprising region adaptive HPF with the transient improvement (TI) method, as well as artifacts and noise reduction (ANR), was developed for degraded X-ray fluoroscopic images. The proposed method was applied in a static scene pre-processed by a low-dose X-ray fluoroscopy device. First, the sharpness of the X-ray image was improved using region adaptive HPF with the TI method, which facilitates sharpening of edge details without overshoot problems. Then, an ANR filter that uses an edge directional kernel was developed to remove the artifacts and noise that can occur during sharpening, while preserving edge details. The quantitative and qualitative results obtained by applying the developed method to low-dose X-ray fluoroscopic images and visually and numerically comparing the final images with images improved using conventional edge enhancement techniques indicate that the proposed method outperforms existing edge enhancement methods in terms of objective criteria and subjective visual perception of the actual X-ray fluoroscopic image. The developed edge enhancement algorithm performed well when applied to actual low-dose X-ray fluoroscopic images, not only by improving the sharpness, but also by removing artifacts and noise, including overshoot. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Clinical application of percutaneous gastrostomy and gastrojejunostomy under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Zhou Jianping; Wang Zhongmin; Liu Tao; Chen Kemin; Gong Ju; Zheng Yunfeng; Chen Zhijin; Shen Jieyun

    2011-01-01

    Objective: To evaluate the safety and effectiveness of percutaneous gastrostomy (PRG) and gastrojejunostomy (PRGJ) under fluoroscopic guidance, and to discuss its technical manipulation, the indications and contraindications as well as the complications. Methods: During the period from May 2002 to June 2010 in authors' hospital fluoroscopically-guided PRG or PRGJ was carried out in 40 patients. The clinical data were retrospectively analyzed. With Seldinger technique and under fluoroscopic guidance, a 14 F radiopaque gastrostomy or gastrojejunostomy feeding catheter was successfully placed. The indications, operation procedures, clinical success rate, procedure-related complications, and tube indwelling time, etc. were discussed and analyzed. Results: PRG was conducted in 30 patients. The reasons for performing PRG included neurologic disease (n=13), recurrent aspiration pneumonia (n=6), gastroesophageal reflux due to disfunction of gastrointestinal tract (n=3), subtotal gastrectomy (n=2), esophagomediastinal fistula (n=1) and esophageal carcinoma (n=5). PRGJ was carried out in 10 patients. The disorders included bulbar paralysis (n=3), malignant duodenal obstruction (n=4) and previous gastrostomy-related complications (n=3). Two anchors were used in all patients receiving PRG or PRGJ. Clinical success was achieved in all study patients. No procedure-related or severe complications occurred. Minor complications were observed in four patients (10%), which included local soft tissue infection (n=1), severe puncture site pain (n=1), gastrostomy tube dislodgement (n=1) and obstruction of gastrojejunostomy tube (n=1). During the follow-up period, no aggravation of gastroesophageal reflux or aspiration pneumonia was observed in all patients. The tube indwelling time was 115 to 585 days (mean of 150 days) after tube placement. Conclusion: Fluoroscopically-guided percutaneous gastrostomy or gastrojejunostomy is a safe, simple and minimally-invasive technique. This

  16. Patient dose measurements in fluoroscopic examinations, aiming to the establishment of reference levels in Brazil

    International Nuclear Information System (INIS)

    Canevaro, L.; Drexler, G.

    2001-01-01

    This work was performed to investigate the actual exposure levels of the patients submitted to fluoroscopic procedures in diagnostic radiology. The data will be useful for a baseline in the establishment of local reference levels for fluoroscopic procedures, as recommended by the European Commission and IAEA. At present time there are no internationally accepted definitions for references levels for fluoroscopic complex procedures. Dose-area product (DAP) meters were employed in a pilot survey expressing the radiation exposures in terms of this quantity. This class of instrumentation has not yet been employed in Brazil. Parameters recorded were radiographic technique, fluoroscopy time, number of images, fluoroscopic and radiographic field sizes and DAPs. For fluoroscopy practice, a reference parameters set is recommended, instead of one diagnostic reference level. High patient exposures were found, calling for joined actions of health authorities, physicians, medical physicists, technicians and manufacturers. Monitoring of patient exposure, optimizing the radiation protection and establishing quantitative assessments of the exposition to the population in Brazil in this kind of procedure is important. (author)

  17. Cryo-balloon catheter localization in fluoroscopic images

    Science.gov (United States)

    Kurzendorfer, Tanja; Brost, Alexander; Jakob, Carolin; Mewes, Philip W.; Bourier, Felix; Koch, Martin; Kurzidim, Klaus; Hornegger, Joachim; Strobel, Norbert

    2013-03-01

    Minimally invasive catheter ablation has become the preferred treatment option for atrial fibrillation. Although the standard ablation procedure involves ablation points set by radio-frequency catheters, cryo-balloon catheters have even been reported to be more advantageous in certain cases. As electro-anatomical mapping systems do not support cryo-balloon ablation procedures, X-ray guidance is needed. However, current methods to provide support for cryo-balloon catheters in fluoroscopically guided ablation procedures rely heavily on manual user interaction. To improve this, we propose a first method for automatic cryo-balloon catheter localization in fluoroscopic images based on a blob detection algorithm. Our method is evaluated on 24 clinical images from 17 patients. The method successfully detected the cryoballoon in 22 out of 24 images, yielding a success rate of 91.6 %. The successful localization achieved an accuracy of 1.00 mm +/- 0.44 mm. Even though our methods currently fails in 8.4 % of the images available, it still offers a significant improvement over manual methods. Furthermore, detecting a landmark point along the cryo-balloon catheter can be a very important step for additional post-processing operations.

  18. Radiofrequency catheter ablation: Relationship between fluoroscopic time and skin doses according to diagnoses. Basis to establish a quality assurance programme

    International Nuclear Information System (INIS)

    Cotelo, E.; Pouso, J.; Reyes, W.

    2001-01-01

    Radiofrequency Cardiac Catheter Ablation is an Interventional Radiology procedure of great complexity because the cardiologist needs a simultaneous evaluation of fluoroscopic images and electrophysiologic information. Therefore, the procedure typically involves extended fluoroscopic time that may cause radiation-skin injures to patients. Skin doses depend on many factors: equipment design features and its proper use, cardiologist practice, fluoroscopic time, irradiated areas, application of radiation protection recommendations, etc. We evaluate fluoroscopic time in relation to pathology and we estimate skin doses on 233 procedures at the Electrophysiology Laboratory in Casa de Galicia, Montevideo, Uruguay. Significant differences among the medians of fluoroscopic time were found in those procedures depending on diagnoses and results. Higher fluoroscopic time was found in flutter and auricular tachycardia (median was 83 minutes, p=0.0001). In successful procedures (almost 90%), median skin doses was 2.0 Grays (p=0.0001). On the basis of records information, the standard operating procedure and the clinical protocol, expanding close cooperation between the cardiologists and the experts in Radiation Protection will secure the establishment of an Assurance Quality Program. (author)

  19. Management of pediatric radiation dose using GE fluoroscopic equipment

    International Nuclear Information System (INIS)

    Belanger, Barry; Boudry, John

    2006-01-01

    In this article, we present GE Healthcare's design philosophy and implementation of X-ray imaging systems with dose management for pediatric patients, as embodied in its current radiography and fluoroscopy and interventional cardiovascular X-ray product offerings. First, we present a basic framework of image quality and dose in the context of a cost-benefit trade-off, with the development of the concept of imaging dose efficiency. A set of key metrics of image quality and dose efficiency is presented, including X-ray source efficiency, detector quantum efficiency (DQE), detector dynamic range, and temporal response, with an explanation of the clinical relevance of each. Second, we present design methods for automatically selecting optimal X-ray technique parameters (kVp, mA, pulse width, and spectral filtration) in real time for various clinical applications. These methods are based on an optimization scheme where patient skin dose is minimized for a target desired image contrast-to-noise ratio. Operator display of skin dose and Dose-Area Product (DAP) is covered, as well. Third, system controls and predefined protocols available to the operator are explained in the context of dose management and the need to meet varying clinical procedure imaging demands. For example, fluoroscopic dose rate is adjustable over a range of 20:1 to adapt to different procedure requirements. Fourth, we discuss the impact of image processing techniques upon dose minimization. In particular, two such techniques, dynamic range compression through adaptive multiband spectral filtering and fluoroscopic noise reduction, are explored in some detail. Fifth, we review a list of system dose-reduction features, including automatic spectral filtration, virtual collimation, variable-rate pulsed fluoroscopic, grid and no-grid techniques, and fluoroscopic loop replay with store. In addition, we describe a new feature that automatically minimizes the patient-to-detector distance, along with an

  20. Scale-space for empty catheter segmentation in PCI fluoroscopic images.

    Science.gov (United States)

    Bacchuwar, Ketan; Cousty, Jean; Vaillant, Régis; Najman, Laurent

    2017-07-01

    In this article, we present a method for empty guiding catheter segmentation in fluoroscopic X-ray images. The guiding catheter, being a commonly visible landmark, its segmentation is an important and a difficult brick for Percutaneous Coronary Intervention (PCI) procedure modeling. In number of clinical situations, the catheter is empty and appears as a low contrasted structure with two parallel and partially disconnected edges. To segment it, we work on the level-set scale-space of image, the min tree, to extract curve blobs. We then propose a novel structural scale-space, a hierarchy built on these curve blobs. The deep connected component, i.e. the cluster of curve blobs on this hierarchy, that maximizes the likelihood to be an empty catheter is retained as final segmentation. We evaluate the performance of the algorithm on a database of 1250 fluoroscopic images from 6 patients. As a result, we obtain very good qualitative and quantitative segmentation performance, with mean precision and recall of 80.48 and 63.04% respectively. We develop a novel structural scale-space to segment a structured object, the empty catheter, in challenging situations where the information content is very sparse in the images. Fully-automatic empty catheter segmentation in X-ray fluoroscopic images is an important and preliminary step in PCI procedure modeling, as it aids in tagging the arrival and removal location of other interventional tools.

  1. Diagnosis of cardiovascular diseases by digital fluoroscopic angiography

    International Nuclear Information System (INIS)

    Takahashi, Mutsumasa; Hirota, Yoshihisa; Tsuchigame, Naotoshi

    1982-01-01

    Digital fluoroscopic angiography (DFA) is a recently developed angiocardiographic technique, which consists of digitization and real-time subtraction of X-ray transmission data from an image intensifier and television fluoroscopic system. A prototype unit based on this principle was developed and installed at our hospital and initial clinical trial has been performed. Fifty-three examinations were performed on 49 patients with various cardiovascular conditions. DFA was useful in demonstration of intracardiac shunt, and valvular diseases secondary to congenital heart diseases. In ischemic heart diseases, DFA noninvasively demonstrated the heart wall motion, making it possible to evaluate dyskinesis, akinesis and ventricular aneurysm. DFA was also valuable in visualizing disproportionate enlargement of cardiac chambers, stasis, and frequently regurgitation of contrast media in valvular heart diseases. Abnormal mediastinal enlargement and aortic aneurysm were differentiated from other conditions to good advantage. DFA will be used more widely in the above conditions because of non-invasive and simple procedures. Future effort should be directed towards improvement of spatial resolution and development of new algorithm for hemodynamic evaluation. (author)

  2. Fluoroscopic dose reduction by acquisition frame rate reduction and image processing

    International Nuclear Information System (INIS)

    Fritz, S.L.; Mirvis, S.E.; Pals, S.O.

    1986-01-01

    A new design for fluoroscopic exposure reduction incorporates pulsed x-ray exposure, progressive scan video acquisition at frame rates below 30 Hz, interlaced video display at 30 Hz, and a video rate image processing. To evaluate this design, a variety of phantom systems have been developed to measure the impact of low frame rate pulsed digital fluoroscopy on the performance of several clinical tasks (e.g., catheter placement). The authors are currently using these phantoms with a digital fluoroscopy system using continuous x-ray, interlaced video acquisition and variable acquisition frame rate. The design of their target digital fluoroscopic system, sample image sequences, and the results of some preliminary phantom studies are reported

  3. Experiences upgrading a fluoroscopic system to digital specifications

    International Nuclear Information System (INIS)

    Fox, T.; Fenzl, G.

    1995-01-01

    In 1993, an undertable fluoroscopic system was retrofitted with a Fluorospot HC digital system at the radiological clinic of the Knappschaftskrankenhaus in Puettlingen, Germany. The experiences and possibilities resulting from this digital upgrade are related by the authors, whose narrative is also accompanied by examples of clinical images. The costs involved are also discussed in this article. (orig.)

  4. Adjustable radiation protection device of the fluoroscope DG 10

    International Nuclear Information System (INIS)

    Hoermann, D.

    1980-01-01

    In cooperation with the 'VEB Transformatoren- und Roentgenwerk Hermann Matern', Dresden, an adjustable radiation protection device has been developed. This supplementary equipment for fluoroscopes ensures a sufficient protection of the gonads against undesirable X radiation, can be handled easily and does not annoy patients, esp. children

  5. SU-D-209-02: Percent Depth Dose Curves for Fluoroscopic X-Ray Beam Qualities Incorporating Copper Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Wunderle, K [Cleveland Clinic Foundation, Cleveland, OH (United States); Wayne State University School of Medicine, Detroit, MI (United States); Godley, A; Shen, Z; Dong, F [Cleveland Clinic Foundation, Cleveland, OH (United States); Rakowski, J [Wayne State University School of Medicine, Detroit, MI (United States)

    2016-06-15

    Purpose: The purpose of this investigation was to quantify percent depth dose (PDD) curves for fluoroscopic x-ray beam qualities incorporating added copper filtration. Methods: A PTW (Freiburg, Germany) MP3 water tank was used with a Standard Imaging (Middleton, WI) Exradin Model 11 Spokas Chamber to measure PDD curves for 60, 80, 100 and 120 kVp x-ray beams with copper filtration ranging from 0.0–0.9 mm at 22cm and 42cm fields of view from 0 to 150 mm of water. A free-in-air monitor chamber was used to normalize the water tank data to fluctuations in output from the fluoroscope. The measurements were acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope. The fluoroscope was inverted from the typical orientation providing an x-ray beam originating from above the water tank. The water tank was positioned so that the water level was located at 60cm from the focal spot; which also represents the focal spot to interventional reference plane distance for that fluoroscope. Results: PDDs for 60, 80, 100, and 120 kVp with 0 mm of copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)] for those beam qualities given differences in fluoroscopes, geometric orientation, type of ionization chamber, and the water tank used for data collection. PDDs for 60, 80, 100, and 120 kVp with copper filtration were obtained and are presented, which have not been previously investigated and published. Conclusion: The equipment and processes used to acquire the reported data were sound and compared well with previously published data for PDDs without copper filtration. PDD data for the fluoroscopic x-ray beams incorporating copper filtration can be used as reference data for estimating organ or soft tissue dose at depth involving similar beam qualities or for comparison with mathematical models.

  6. Fluoroscopic guidance of retrograde exchange of ureteral stents in women.

    Science.gov (United States)

    Chang, Ruey-Sheng; Liang, Huei-Lung; Huang, Jer-Shyung; Wang, Po-Chin; Chen, Matt Chiung-Yu; Lai, Ping-Hong; Pan, Huay-Ben

    2008-06-01

    The purpose of this study was to review our experience with fluoroscopically guided retrograde exchange of ureteral stents in women. During a 48-month period, 28 women (age range, 38-76 years) were referred to our department for retrograde exchange of a ureteral stent. The causes of urinary obstruction were tumor compression in 26 patients and benign fibrotic stricture in two patients. A large-diameter snare catheter (25-mm single loop or 18- to 35-mm triple loop) or a foreign body retrieval forceps (opening width, 11.3 mm) was used to grasp the bladder end of the stent under fluoroscopic guidance. The technique entailed replacement of a patent or occluded ureteral stent with a 0.035- or 0.018-inch guidewire with or without the aid of advancement of an angiographic sheath. A total of 54 ureteral stents were exchanged with a snare catheter in 42 cases or a forceps in 12 cases. One stent misplaced too far up the ureter was replaced successfully through antegrade percutaneous nephrostomy. Ten occluded stents, including one single-J stent, were managed with a 0.018-inch guidewire in three cases, advancement of an angiographic sheath over the occluded stent into the ureter in five cases, and recannulation of the ureteral orifice with a guidewire in two cases. No complications of massive hemorrhage, ureter perforation, or infection were encountered. With proper selection of a snare or forceps catheter, retrograde exchange of ureteral stents in women can be easily performed under fluoroscopic guidance with high technical success and a low complication rate.

  7. Common fluoroscopic studies in radiology : conduct and analysis method

    International Nuclear Information System (INIS)

    Valverde Sanchez, Allan

    2011-01-01

    A countless number of radiological procedures, that have involved the use of fluoroscopy and contrast media of different indole, have been carried out in all radiology services and medical images of Costa Rica for the diagnosis of diseases or conditions, in both adults and in children. Fluoroscopic studies, often called special or contrast studies, have had particular conditions for its realization. Some from the medical point of view: adequate training in the technical and cognitive development when evaluating the images to not miss important details. Other by the patient: adequate preparation to achieve the best images for optimal diagnosis. For example, adequate bowel preparation is essential for a barium enema, to cooperation by the patient to meet specific indications that the physician dictates when swallowing postures or just when you are prompted. Criteria have been met and unified for contrast studies in different hospitals and clinics. The indications, contra, method, technique of procedure, points to remember, number of images or projections minimum required in the interpretation of contrast studies, as well as a report template of standard and ideal study are presented in a simple, systematic and logical. The manual is intended for residents and attending physicians specialists in radiology and medical imaging including contrast studies more common. Spaces are promoted with current technology studies to set aside more complicated and less sophisticated as have been the fluoroscopic studies; however, in the national reality, access to computerized tomography and magnetic resonance imaging is not as easy. Radiological studies with fluoroscopy performed by trained staff led the treating physician to make sound decisions based on studies relatively simple and easy to do. The tests with the use of fluoroscopic have been named: the esophagogram, gastroduodenal series, gastro intestinal transit, the hysterosalpingography, the cystography and the

  8. Role of fluoroscopic guided self expandable metallic stents in the management of malignant esophageal strictures

    OpenAIRE

    Mohamed Shaker; Ahmed Deif; Amr Abdelaal

    2016-01-01

    Objectives: To evaluate the role of fluoroscopic guided self expanding metallic stents in the management of dysphagia caused by malignant esophageal strictures. Materials and methods: During the period between April 2010 and October 2012, 31 patients with malignant esophageal strictures were subjected to fluoroscopic guided self expanding metallic stent application. The study included 22 males and 9 females ranging in age between 22 and 75 years old with mean age of 56.8 years. Lesions wer...

  9. Measurements for testing of fluoroscopic screens, including the photofluorographic units

    International Nuclear Information System (INIS)

    Balfanz, R.

    1986-01-01

    Image quality control measurements for fluoroscopic screens and photofluorographs have shown that both types of equipment have a long operating life, so that constancy and technical performance tests are absolutely necessary. It is recommended to conclude in-service maintenance contracts with the manufacturers. (DG) [de

  10. Registration of angiographic image on real-time fluoroscopic image for image-guided percutaneous coronary intervention.

    Science.gov (United States)

    Kim, Dongkue; Park, Sangsoo; Jeong, Myung Ho; Ryu, Jeha

    2018-02-01

    In percutaneous coronary intervention (PCI), cardiologists must study two different X-ray image sources: a fluoroscopic image and an angiogram. Manipulating a guidewire while alternately monitoring the two separate images on separate screens requires a deep understanding of the anatomy of coronary vessels and substantial training. We propose 2D/2D spatiotemporal image registration of the two images in a single image in order to provide cardiologists with enhanced visual guidance in PCI. The proposed 2D/2D spatiotemporal registration method uses a cross-correlation of two ECG series in each image to temporally synchronize two separate images and register an angiographic image onto the fluoroscopic image. A guidewire centerline is then extracted from the fluoroscopic image in real time, and the alignment of the centerline with vessel outlines of the chosen angiographic image is optimized using the iterative closest point algorithm for spatial registration. A proof-of-concept evaluation with a phantom coronary vessel model with engineering students showed an error reduction rate greater than 74% on wrong insertion to nontarget branches compared to the non-registration method and more than 47% reduction in the task completion time in performing guidewire manipulation for very difficult tasks. Evaluation with a small number of experienced doctors shows a potentially significant reduction in both task completion time and error rate for difficult tasks. The total registration time with real procedure X-ray (angiographic and fluoroscopic) images takes [Formula: see text] 60 ms, which is within the fluoroscopic image acquisition rate of 15 Hz. By providing cardiologists with better visual guidance in PCI, the proposed spatiotemporal image registration method is shown to be useful in advancing the guidewire to the coronary vessel branches, especially those difficult to insert into.

  11. Fluoroscopic tomography. [for body section synthesis

    Science.gov (United States)

    Baily, N. A.; Crepeau, R. L.; Lasser, E. C.

    1974-01-01

    A fluoroscopic tomography system capable of synthesizing body sections at a number of levels within the body has been developed. The synthesized body sections may lie either in a range of planes parallel to, tilted with respect to, skewed with respect to, or both tilted and skewed with respect to the plane of motion of the X-ray tube target. In addition, body sections can be presented which are contoured to the patient's anatomy. That is to say, they may even encompass such complex surfaces as a quadratic hyperplane. In addition, tomograms of organs in motion can be imaged.

  12. General-purpose radiographic and fluoroscopic table

    International Nuclear Information System (INIS)

    Ishizaki, Noritaka

    1982-01-01

    A new series of diagnostic tables, Model DT-KEL, was developed for general-purpose radiographic and fluoroscopic systems. Through several investigations, the table was so constructed that the basic techniques be general radiography and GI examination, and other techniques be optionally added. The diagnostic tables involve the full series of the type for various purposes and are systematized with the surrounding equipment. A retractable mechanism of grids was adopted first for general use. The fine grids with a density of 57 lines per cm, which was adopted in KEL-2, reduced the X-ray doses by 16 percent. (author)

  13. Fluoroscopically-guided foam sclerotherapy with sodium morrhuate for the treatment of lower extremity varices

    International Nuclear Information System (INIS)

    Wang Haiting; Jiang Zhongpu; Zhou Yi

    2011-01-01

    Objective: To evaluate fluoroscopically-guided foam sclerotherapy with injection of domestic sodium morrhuate in treating lower extremity varices. Methods: A total of 30 cases (39 diseased lower limbs) with lower extremity varices were enrolled in this study. Under fluoroscopic guidance foam sclerotherapy with injection of domestic sodium morrhuate was carried out in all patients. The obstructed condition of the great saphenous vein was observed during the following three months. Results: The technical success was achieved in all 39 patients. The mean dose of foam sclerosant used for each diseased limb was 5.9 ml (3.4-8.2 ml). Disappearance of blood flow reflux in lower extremity vein immediately after the treatment was seen in 35 patients (90%). Three months after the therapy, vascular sonography showed that the great saphenous vein was obstructed, and no serious complications occurred. Conclusion: For the treatment of lower extremity varices, fluoroscopically-guided foam sclerotherapy with injection of domestic sodium morrhuate is safe and effective with satisfactory results. This technique is a newly-developed micro-invasive therapy for lower extremity varices. (authors)

  14. Real-Time Verification of a High-Dose-Rate Iridium 192 Source Position Using a Modified C-Arm Fluoroscope

    Energy Technology Data Exchange (ETDEWEB)

    Nose, Takayuki, E-mail: nose-takayuki@nms.ac.jp [Department of Radiation Oncology, Nippon Medical School Tamanagayama Hospital, Tama (Japan); Chatani, Masashi [Department of Radiation Oncology, Osaka Rosai Hospital, Sakai (Japan); Otani, Yuki [Department of Radiology, Kaizuka City Hospital, Kaizuka (Japan); Teshima, Teruki [Department of Radiation Oncology, Osaka Medical Center for Cancer and Cardiovascular Diseases, Osaka (Japan); Kumita, Shinichirou [Department of Radiology, Nippon Medical School Hospital, Tokyo (Japan)

    2017-03-15

    Purpose: High-dose-rate (HDR) brachytherapy misdeliveries can occur at any institution, and they can cause disastrous results. Even a patient's death has been reported. Misdeliveries could be avoided with real-time verification methods. In 1996, we developed a modified C-arm fluoroscopic verification of an HDR Iridium 192 source position prevent these misdeliveries. This method provided excellent image quality sufficient to detect errors, and it has been in clinical use at our institutions for 20 years. The purpose of the current study is to introduce the mechanisms and validity of our straightforward C-arm fluoroscopic verification method. Methods and Materials: Conventional X-ray fluoroscopic images are degraded by spurious signals and quantum noise from Iridium 192 photons, which make source verification impractical. To improve image quality, we quadrupled the C-arm fluoroscopic X-ray dose per pulse. The pulse rate was reduced by a factor of 4 to keep the average exposure compliant with Japanese medical regulations. The images were then displayed with quarter-frame rates. Results: Sufficient quality was obtained to enable observation of the source position relative to both the applicators and the anatomy. With this method, 2 errors were detected among 2031 treatment sessions for 370 patients within a 6-year period. Conclusions: With the use of a modified C-arm fluoroscopic verification method, treatment errors that were otherwise overlooked were detected in real time. This method should be given consideration for widespread use.

  15. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark

    1997-01-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis

  16. Correction of malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Ryong; Baek, Kyong Hee; Jung, Gyoo Sik; Huh, Jin Do; Joh, Young Duk; Rim, Hark [Kosin Medical College, Pusan (Korea, Republic of)

    1997-11-01

    To determine the efficacy of correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance. Between November 1994 and March 1997, we performed 15 manipulations in 12 patients in whom a dual-cuff, straight Tenckhoff peritoneal dialysis catheter had been implanted due to chronic renal failure. The causes of catheter malfunctioning were inadequate drainage of the dialysate(n=14) and painful dialysis(n=1). Under fluoroscopic guidance, adhesiolysis and repositioning of the malfunctioning catheter were performed with an Amplatz Super Stiff guidewire and the stiffener from a biliary drainage catheter. The results of procedures were categorized as either immediate or durable success, this latter being defined as adequate catheter function for at least one month after the procedure. Immediate success was achieved in 14 of 15 procedures (93%), and durable success in 7 of 15(47%). The mean duration of catheter function was 157 (range, 30 to 578) days. After manipulation, abdominal pain developed in eight patients and peritonitis in two, but with conservative treatment, these symptoms improved. The correction of a malfunctioning peritoneal dialysis catheter with guidewire and stiffener under fluoroscopic guidance is an effective means of restoring catheter function and may be an effective alternative to surgical reimplantation of the catheter, or hemodialysis.

  17. Fluoroscopic-guided covered metallic stent placement for gastric outlet obstruction and post-operative gastroenterostomy anastomotic stricture

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Young; Lee, Soo Teik; Yang, Doo Hyun

    2001-07-01

    AIM: To evaluate the feasibility and safety of fluoroscopic-guided covered metallic stent placements in providing palliative care for patients with inoperable malignant gastric outlet obstruction. MATERIALS AND METHODS: Under fluoroscopic guidance, placement of self-expandable, covered stents was attempted in 20 patients with inoperable or recurrent gastric cancer (age range 36-79 years). All patients had inoperable gastric outlet obstruction, 13 with native anatomy and seven with post-operative anatomy (gastrointestinal anastomotic sites). All patients had intolerance to oral alimentation and/or vomiting after ingestion. Success was defined both technically and clinically. RESULTS: The placement of the stent was technically successful in 18 patients and failed in two patients (technical success: 90%). The cause of the technical failures was an inability to negotiate the guide wire through the obstruction sites in spite of the use of both fluoroscopic and endoscopic guidance. After stent placement, 15 patients were able to ingest at least liquids and had a markedly decreased incidence of vomiting (clinical success: 75%). During the mean follow-up of 6 weeks, there have been no stent reocclusion and no life-threatening complications except migration of two stents in one patient. CONCLUSION: Fluoroscopically guided covered metallic stent placement appears to be valuable for the palliative treatment of malignant obstruction of gastric outlet and post-operative gastrointestinal anastomoses. Lee, J.M. et al. (2001)

  18. Echocardiographic and Fluoroscopic Fusion Imaging for Procedural Guidance: An Overview and Early Clinical Experience.

    Science.gov (United States)

    Thaden, Jeremy J; Sanon, Saurabh; Geske, Jeffrey B; Eleid, Mackram F; Nijhof, Niels; Malouf, Joseph F; Rihal, Charanjit S; Bruce, Charles J

    2016-06-01

    There has been significant growth in the volume and complexity of percutaneous structural heart procedures in the past decade. Increasing procedural complexity and accompanying reliance on multimodality imaging have fueled the development of fusion imaging to facilitate procedural guidance. The first clinically available system capable of echocardiographic and fluoroscopic fusion for real-time guidance of structural heart procedures was approved by the US Food and Drug Administration in 2012. Echocardiographic-fluoroscopic fusion imaging combines the precise catheter and device visualization of fluoroscopy with the soft tissue anatomy and color flow Doppler information afforded by echocardiography in a single image. This allows the interventionalist to perform precise catheter manipulations under fluoroscopy guidance while visualizing critical tissue anatomy provided by echocardiography. However, there are few data available addressing this technology's strengths and limitations in routine clinical practice. The authors provide a critical review of currently available echocardiographic-fluoroscopic fusion imaging for guidance of structural heart interventions to highlight its strengths, limitations, and potential clinical applications and to guide further research into value of this emerging technology. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  19. Use of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement

    International Nuclear Information System (INIS)

    Bae, Jae-Ik; Shin, Ji Hoon; Song, Ho-Young; Yoon, Chang Jin; Nam, Deok Ho; Choi, Won-Chan; Lim, Jin-Oh

    2005-01-01

    Our purpose was to assess the safety and usefulness of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement. Two types of guiding sheath were made from straight polytetrafluoroethylene tubes. Type A was 80 cm in length, 4 mm in outer diameter and 3 mm in inner diameter. Type B was 70 cm in length, 6 mm in outer diameter and 5 mm in inner diameter. The type A sheath was used in 18 patients in whom a catheter-guide wire combination failed to pass through a stricture. The type B sheath was used in 22 patients in whom a stent delivery system failed to pass through the stricture due to loop formation within the gastric lumen. The overall success rate for guiding a catheter-guide wire through a stricture after using the type A sheath was 89%. The overall success rate for passing a stent delivery system through a stricture after using the type B sheath was 100%. All procedures were tolerated by the patients without any significant complications. The guiding sheaths were safe and useful in peroral fluoroscopic gastroduodenal stent placement. (orig.)

  20. Short-term outcome of fluoroscopic-guided steroid injection therapy of lumber facet cyst-induced radicular pain

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Mi Ri; Kwon, Jong Won; Lee, Jong Seo; Kim, Eu Sang [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2015-04-15

    To determine the short-term effect of fluoroscopic-guided steroid injection therapy of lumbar facet cyst-induced radicular pain. Seventeen patients with radiculopathy due to lumbar synovial cysts, who were treated with fluoroscopically guided injection, were retrospectively evaluated. All plain radiographic images and MR images before the therapy were reviewed. Five patients underwent only the facet joint injection, whereas twelve patients underwent the facet joint injection with perineural injection therapy. The clinical course of pain was evaluated on the first follow-up after therapy. Effective pain relief was achieved in 11 (64.7%) of the 17 patients. Among 12 patients who underwent facet joint injection with perineural injection, 9 patients (75%) had an effective pain relief. Of 5 patients, 2 (40%) patients only took the facet joint injection and had an effective pain relief. Fluoroscopic-guided steroid injection therapy shows a good short-term effect in patients with symptomatic lumbar facet joint synovial cysts.

  1. Image quality evaluation and patient dose assessment of medical fluoroscopic X-ray systems: A national study

    International Nuclear Information System (INIS)

    Economides, S.; Hourdakis, C. J.; Kalivas, N.; Kalathaki, M.; Simantirakis, G.; Tritakis, P.; Manousaridis, G.; Vogiatzi, S.; Kipouros, P.; Boziari, A.; Kamenopoulou, V.

    2008-01-01

    This study presents the results from a survey conducted by the Greek Atomic Energy Commission (GAEC), during the period 1998-2003, in 530 public and private owned fluoroscopic X-ray systems in Greece. Certain operational parameters for conventional and remote control systems were assessed, according to a quality control protocol developed by GAEC on the basis of the current literature. Public (91.5%) and private (81.5%) owned fluoroscopic units exhibit high-contrast resolution values over 1 lp mm -1 . Moreover, 88.5 and 87.1% of the fluoroscopic units installed in the public and private sector, respectively, present Maximum Patient Entrance Kerma Rate values lower than 100 mGy min -1 . Additionally, 68.3% of the units assessed were found to perform within the acceptance limits. Finally, the third quartile of the Entrance Surface Dose Rate distribution was estimated according to the Dose Reference Level definition and found equal to 35 mGy min -1 . (authors)

  2. Nonsurgical Fluoroscopically Guided Dacryocystoplasty of Common Canalicular Obstructions

    Energy Technology Data Exchange (ETDEWEB)

    Wilhelm, Kai E; Hofer, Ulrich; Textor, Hans J [Department of Radiology, University Hospital Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany); Boeker, Thorsten [Department of Ophthalmology, University Hospital Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany); Strunk, Holger; Schild, Hans H [Department of Radiology, University Hospital Bonn, Sigmund-Freud-Strasse 25, D-53127 Bonn (Germany)

    2000-01-15

    Purpose: To assess dacryocystoplasty in the treatment of epiphora due to obstructions of the common canaliculus.Methods: Twenty patients with severe epiphora due to partial (n = 16) or complete (n = 4) obstruction of the common canaliculus underwent fluoroscopically guided dacryocystoplasty. In all cases of incomplete obstruction balloon dilation was performed. Stent implantation was attempted in cases with complete obstruction. Dacryocystography and clinical follow-up was performed at intervals of 1 week, and 3, 6, 12, and 18 months after the procedure. The mean follow-up was 6 months (range 3-18 months).Results: Balloon dilation was technically successfully performed in all patients with incomplete obstructions (n = 16). In three of four patients with complete obstruction stent implantation was performed successfully. Subsequent to failure of stent implantation in one of these patients balloon dilation was performed instead. The long-term primary patency rate in patients with incomplete obstructions was 88% (n = 14/16). In three of four cases with complete obstruction long-term patency was achieved during follow-up. Severe complications, infections, or punctal splitting were not observed.Conclusion: Fluoroscopically guided balloon dacryocystoplasty is a feasible nonsurgical therapy in canalicular obstructions with good clinical results that may be used as an alternative to surgical procedures. In patients with complete obstructions stent placement is possible but further investigations are needed to assess the procedural and long-term results.

  3. Nonsurgical Fluoroscopically Guided Dacryocystoplasty of Common Canalicular Obstructions

    International Nuclear Information System (INIS)

    Wilhelm, Kai E.; Hofer, Ulrich; Textor, Hans J.; Boeker, Thorsten; Strunk, Holger; Schild, Hans H.

    2000-01-01

    Purpose: To assess dacryocystoplasty in the treatment of epiphora due to obstructions of the common canaliculus.Methods: Twenty patients with severe epiphora due to partial (n = 16) or complete (n = 4) obstruction of the common canaliculus underwent fluoroscopically guided dacryocystoplasty. In all cases of incomplete obstruction balloon dilation was performed. Stent implantation was attempted in cases with complete obstruction. Dacryocystography and clinical follow-up was performed at intervals of 1 week, and 3, 6, 12, and 18 months after the procedure. The mean follow-up was 6 months (range 3-18 months).Results: Balloon dilation was technically successfully performed in all patients with incomplete obstructions (n = 16). In three of four patients with complete obstruction stent implantation was performed successfully. Subsequent to failure of stent implantation in one of these patients balloon dilation was performed instead. The long-term primary patency rate in patients with incomplete obstructions was 88% (n = 14/16). In three of four cases with complete obstruction long-term patency was achieved during follow-up. Severe complications, infections, or punctal splitting were not observed.Conclusion: Fluoroscopically guided balloon dacryocystoplasty is a feasible nonsurgical therapy in canalicular obstructions with good clinical results that may be used as an alternative to surgical procedures. In patients with complete obstructions stent placement is possible but further investigations are needed to assess the procedural and long-term results

  4. Trial manufacture of round mask for TV fluoroscopic unit

    International Nuclear Information System (INIS)

    Matsuoka, Shoji; Matsumoto, Yukio

    1977-01-01

    Demands for revision of existing medical law were described together with an introduction of TV fluoroscopic unit. Round mask, which does not always press out the bottom face of used x-ray beam from the effective primary fluorescent face of photomultiplier inspite of shifting of a spot in time of TV fluoroscopy, was manufactured for trial, and it was furnished with already established fluoroscopic stand. It is used in daily examination without any trouble. Round mask was divided into two parts, and opened upward and downward quickly by lod motor in time of photographing. Multiple iris was operated in order to fit to film size, and round mask was closed at the same time of the finishment of photographing and fluoroscopy was performed again. Item 3 of Para 2 of Art 30 of the existing medical low states that it is good not to press out, the distance between x-ray focus and fluorescent screen, and used x-ray beam from fluorescent screen. However, a regulation, which states that x-ray beam should not be pressed out from effective primary fluorescent face in x-ray fluoroscopy using photomultiplier, must be added. Improvement of the existing unit is expected, and decrease of unnecessary exposure even in small amount is proposed. (Tsunoda, M.)

  5. Estimation of breast doses and breast cancer risk associated with repeated fluoroscopic chest examinations of women with tuberculosis

    International Nuclear Information System (INIS)

    Boice, J.D. Jr.; Rosenstein, M.; Trout, E.D.

    1978-01-01

    A methodology is presented to estimate cumulative breast dose and breast cancer risk for women exposed to repeated fluoroscopic chest examinations during air collapse therapy for pulmonary tuberculosis. Medical record abstraction, physician interview, patient contact, machine exposure measurements, and absorbed dose computations were combined to estimate average breast doses for 1047 Massachusetts women who were treated between 1930 and 1954. The methodology presented considers breast size and composition, patient orientation, x-ray field size and location, beam quality, type of examination, machine exposure rate, and exposure time during fluoroscopic examinations. The best estimate for the risk of radiation-induced cancer for the women living longer than 10 years after initial fluoroscopic exposure is 6.2 excess breast cancers per million woman-year-rad with 90% confidence limits of 2.8 and 10.7 cancers/10 6 WY-rad. When breast cancer risk is considered as a function of absorbed dose in the breast, instead of as a function of the number of fluoroscopic examinations, a linear dose--response relationship over the range of estimated doses is consistent with the data. However, because of the uncertainty due to small-sample variability and because of the wide range of assumptions regarding certain fluoroscopy conditions, other dose--response relationships are compatible with the data

  6. Percutaneous ethanol injection under interventional radiographic computed tomography-fluoroscopic guidance for the treatment of small hepatocellular carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Furuse, Junji; Satake, Mitsuo; Iwasaki, Masahiko; Sekiguchi, Ryuzo; Moriyama, Noriyuki; Yoshino, Masahiro [National Cancer Center, Kashiwa, Chiba (Japan). Hospital East

    1998-04-01

    Some small hepatocellular carcinoma (HCC) lesions show as tumor stains by dynamic CT, but cannot be detected by ultrasonography. Percutaneous ethanol injection (PEI) is effective for treating small HCC lesions, but lack of adequate visualization of some lesions can limit its use. In this study, interventional radiographic, CT-fluoroscopically-guided PEI was performed as a new method for treating small HCC lesions that were difficult to detect by ultrasonography. Interventional radiographic, CT-fluoroscopically-guided PEI was performed on 11 patients (12 lesions) with HCC lesions measuring 2 cm or less in diameter. A thin needle was introduced into each tumor under CT-fluoroscopic guidance, with injection of contrast medium into the dominant hepatic artery. While lesions were observed using CT-fluoroscopy with the arteriogram, absolute ethanol was injected into the tumors. The ethanol injection rate and volume were monitored by observation of loss of tumor staining during real-time CT angiography. Needle introduction was successful in all 12 lesions, and disappearance of tumor staining was immediately observed on CT images after ethanol injection. Complications noted after treatment were local abdominal pain in all 11 patients, a slight fever in 9 patients, pneumothorax, right pleural effusion, and ascites, each in 1 patient. No other serious complications were observed. Interventional radiographic, CT-fluoroscopically-guided PEI is effective in the treatment of small HCC lesions, which are difficult to show by ultrasonography and treat by conventional PEI. (author)

  7. Role of fluoroscopic guided self expandable metallic stents in the management of malignant esophageal strictures

    Directory of Open Access Journals (Sweden)

    Mohamed Shaker

    2016-09-01

    Conclusion: Fluoroscopic guided esophageal stenting is a highly effective and safe method for palliating dysphagia in patients with obstructing esophageal cancer with significant clinical improvement.

  8. Video dosimetry: evaluation of X-radiation dose by video fluoroscopic image

    International Nuclear Information System (INIS)

    Nova, Joao Luiz Leocadio da; Lopes, Ricardo Tadeu

    1996-01-01

    A new methodology to evaluate the entrance surface dose on patients under radiodiagnosis is presented. A phantom is used in video fluoroscopic procedures in on line video signal system. The images are obtained from a Siemens Polymat 50 and are digitalized. The results show that the entrance surface dose can be obtained in real time from video imaging

  9. SU-F-I-76: Fluoroscopic X-Ray Beam Profiles for Spectra Incorporating Copper Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Wunderle, K [Cleveland Clinic Foundation, Cleveland, OH (United States); Wayne State University School of Medicine, Detroit, MI (United States); Godley, A; Shen, Z; Dong, F [Cleveland Clinic Foundation, Cleveland, OH (United States); Rakowski, J [Wayne State University School of Medicine, Detroit, MI (United States)

    2016-06-15

    Purpose: The purpose of this investigation is to characterize and quantify X-ray beam profiles for fluoroscopic x-ray beam spectra incorporating spectral (copper) filtration. Methods: A PTW (Freiburg, Germany) type 60016 silicon diode detector and PTW MP3 water tank were used to measure X-ray beam profiles for 60, 80, 100 and 120 kVp x-ray beams at five different copper filtration thicknesses ranging from 0–0.9 mm at 22 and 42 cm fields of view and depths of 1, 5, and 10 cm in both the anode-cathode axis (inplane) and cross-plane directions. All measurements were acquired on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope inverted from the typical orientation providing an x-ray beam originating from above the water surface with the water level set at 60 cm from the focal spot. Results: X-ray beam profiles for beam spectra without copper filtration compared well to previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. Our data collection benefited from the geometric orientation of the fluoroscope, providing a beam perpendicular to the tank water surface, rather than through a thin side wall as did the previously mentioned study. Profiles for beams with copper filtration were obtained which have not been previously investigated and published. Beam profiles in the anode-cathode axis near the surface and at lower x-ray energy exhibited substantial heel effect, which became less pronounced at greater depth. At higher energy with copper filtration in the beam, the dose falloff out-of-field became less pronounced, as would be anticipated given higher scatter photon energy. Conclusion: The x-ray beam profile data for the fluoroscopic x-ray beams incorporating copper filtration are intended for use as reference data for estimating doses to organs or soft tissue, including fetal dose, involving similar beam qualities or for comparison with mathematical models.

  10. Transrectal Drainage of Deep Pelvic Abscesses Using a Combined Transrectal Sonographic and Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Jeong, Kyung Soon; Lee, Eun Jung; Ko, Ji Ho; Joh, Young Duk; Jung, Gyoo Sik

    2005-01-01

    To evaluate the feasibility and clinical efficacy of transrectal drainage of a deep pelvic abscess using combined transrectal sonographic and fluoroscopic guidance. From March 1995 and August 2004, 17 patients (9 men; 8 women; mean age, 39 years) suffering from pelvic pain, fever and leukocytosis were enrolled in this retrospective study. Ultrasound (US) or computed tomography (CT), which was obtained prior to the procedure, showed pelvic fluid collections that were deemed unapproachable by the percutaneous trans abdominal routes. Transrectal drainage of the pelvic abscess was performed under combined transrectal sonographic and fluoroscopic guidance. The causes of the deep pelvic abscess were postoperative complications (n=7), complications associated with radiation (n=3) and chemotherapy (n=1) as well as unknown causes (n=6). A 7.5-MHz end-firing transrectal US probe with a needle biopsy guide attachment was advanced into the rectum. Once the abscess was identified, a needle was advanced via the biopsy guide and the abscess was punctured. Under US guidance, either a 0.018'or 0.035' guide wire was passed through the needle in the abscess. Under fluoroscopic guidance, the tract was dilated to the appropriate diameter with sequential fascial dilators, and a catheter was placed over the guide wire within the abscess. Clinical success of drainage was determined by a combination closure of the cavity on the follow up images and diminished leukocytosis. The technical and clinical success rate, complications, and patient's discomfort were analyzed. Drainage was technically successful in all patients and there were no serious complications. Surgery was eventually performed in two cases due to fistular formation with the rectum and leakage of the anastomosis site. The procedure was well tolerated in all but one patient who complained of discomfort while the catheter was inserted . The catheter did not interfere with defecation and there was no incidence of catheter

  11. SU-F-I-75: Half-Value Layer Thicknesses and Homogeneity Coefficients for Fluoroscopic X-Ray Beam Spectra Incorporating Spectral Filtration

    Energy Technology Data Exchange (ETDEWEB)

    Wunderle, K [Cleveland Clinic Foundation, Cleveland, OH (United States); Wayne State University School of Medicine, Detroit, MI (United States); Godley, A; Shen, Z; Dong, F [Cleveland Clinic Foundation, Cleveland, OH (United States); Rakowski, J [Wayne State University School of Medicine, Detroit, MI (United States)

    2016-06-15

    Purpose: The purpose of this investigation is to quantify various first half-value-layers (HVLs), second HVLs and homogeneity coefficients (HCs) for a state-of-the-art fluoroscope utilizing spectral (copper) filtration. Methods: A Radcal (Monrovia, Ca) AccuPro dosimeter with a 10×6-6 calibrated ionization chamber was used to measure air kerma for radiographic x-ray exposures made on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope operated in the service mode. The ionization chamber was centered in the x-ray beam at 72 cm from the focal spot with a source-to-image-distance of 120 cm. The collimators were introduced to limit the x-ray field to approximately 5 cm × 5 cm at the ionization chamber plane. Type-1100 aluminum filters, in 0.5 mm increments, were used to determine the HVL. Two HVL calculation methods were used, log-linear interpolation and Lambert-W interpolation as described by Mathieu [Med Phys, 38(8), 4546 (2011)]. Multiple measurements were made at 60, 80, 100, 120 kVp at spectral filtration thicknesses of 0, 0.1, 0.3, 0.6 and 0.9 mm. Results: First HVL, second HVL, and HCs are presented for the fluoroscopic x-ray beam spectra indicated above, with nearly identical results from the two interpolation methods. Accuracy of the set kVp was also determined and deviated less than 2%. First HVLs for fluoroscopic x-ray beam spectra without spectral filtration determined in our study were 7%–16% greater than previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. However, the FDA minimum HVL requirements changed since that publication, requiring larger HVLs as of 2006. Additionally, x-ray tube and generator architecture have substantially changed over the last 15 years providing different beam spectra. Conclusion: X-ray beam quality characteristics for state-of-the-art fluoroscopes with spectral filtration have not been published. This study provides reference data which will be useful for defining beam qualities encountered on

  12. Radiographic, high detail radiographic, microangiographic and histological findings of the distal portion of the tarsus in weanling young and adult horses

    International Nuclear Information System (INIS)

    Laverty, S.; Stover, S.M.; Bélanger, D.; O'Brien, T.R.; Pool, R.R.; Pascoe, J.R.; Taylor, K.; Harrington, T.

    1991-01-01

    Clinical radiographic (LM and D35L-P1MO reviews), high detail radiographic, microangiographic and histological findings of distal portion of the tarsus of 16 horses (five weanling, four young and six adult), without known clinical histories, were evaluated to determine the sensitivity of clinical radiographs for the detection of abnormalities in the distal tarsus and the prevalence of abnormalities in this population. Clinical radiographic and high detail radiographic abnormalities were observed in at least 30 per cent of the tarsi examined. Statistical agreement between observations from clinical radiographs and corresponding post mortem high detail radiographs was not good for subchondral bone plate irregularities and joint margin changes. Three patterns of sclerosis of the medullary spongiosa were visualized on high detail radiographs; thickening of the subchondral bone plate was seen commonly in the weaning group,, whereas arching and bridging patterns were more prevalent in the young and adult groups. Bone production on the dorsal cortex of the central and third tarsal bones did not increase with age. Abnormalities in vascular perfusion and articular cartilage histology were observed in association with subchondral bone plate irregularities and focal regions of osteopenia observed on high detail radiographs

  13. C-arm cone beam computed tomography needle path overlay for fluoroscopic guided vertebroplasty.

    Science.gov (United States)

    Tam, Alda L; Mohamed, Ashraf; Pfister, Marcus; Chinndurai, Ponraj; Rohm, Esther; Hall, Andrew F; Wallace, Michael J

    2010-05-01

    Retrospective review. To report our early clinical experience using C-arm cone beam computed tomography (C-arm CBCT) with fluoroscopic overlay for needle guidance during vertebroplasty. C-arm CBCT is advanced three-dimensional (3-D) imaging technology that is currently available on state-of-the-art flat panel based angiography systems. The imaging information provided by C-arm CBCT allows for the acquisition and reconstruction of "CT-like" images in flat panel based angiography/interventional suites. As part of the evolution of this technology, enhancements allowing the overlay of cross-sectional imaging information can now be integrated with real time fluoroscopy. We report our early clinical experience with C-arm CBCT with fluoroscopic overlay for needle guidance during vertebroplasty. This is a retrospective review of 10 consecutive oncology patients who underwent vertebroplasty of 13 vertebral levels using C-arm CBCT with fluoroscopic overlay for needle guidance from November 2007 to December 2008. Procedural data including vertebral level, approach (transpedicular vs. extrapedicular), access (bilateral vs. unilateral) and complications were recorded. Technical success with the overlay technology was assessed based on accuracy which consisted of 4 measured parameters: distance from target to needle tip, distance from planned path to needle tip, distance from midline to needle tip, and distance from the anterior 1/3 of the vertebral body to needle tip. Success within each parameter required that the distance between the needle tip and parameter being evaluated be no more than 5 mm on multiplanar CBCT or fluoroscopy. Imaging data for 12 vertebral levels was available for review. All vertebral levels were treated using unilateral access and 9 levels were treated with an extrapedicular approach. Technical success rates were 92% for both distance from planned path and distance from midline to final needle tip, 100% when distance from needle tip to the anterior 1

  14. 28 CFR 552.13 - X-ray, major instrument, fluoroscope, or surgical intrusion.

    Science.gov (United States)

    2010-07-01

    ... 28 Judicial Administration 2 2010-07-01 2010-07-01 false X-ray, major instrument, fluoroscope, or... INSTITUTIONAL MANAGEMENT CUSTODY Searches of Housing Units, Inmates, and Inmate Work Areas § 552.13 X-ray, major... reasons only, with the inmate's consent. (b) The institution physician may authorize use of an X-ray for...

  15. An engineering development of fluoroscopic X-ray medical equipment based-on fluorescent screen

    International Nuclear Information System (INIS)

    Ferry Suyatno; I Putu Susila; Djoko Sukmono

    2011-01-01

    Fluoroscopic x-ray medical equipment uses fluorescent screen to capture structural image of organs. Unlike conventional x-ray equipment which uses film, in the fluoroscopic x-ray, the resulting image is visualized on the fluorescent screen and directly observed by physicians in the patients' rooms. In this study, we developed an image capture system that transforms the image on the fluorescent screen into digital data, which is then transferred to computer for visualization and further processing. By using this system, the observation of the resulting image can be done on a computer that is placed in the control room. The image can also be stored easily and at low cost compared to conventional film. The experiment shows that the system could be used to capture image of the object. However, its quality needs to be improved. In the future, the system will be modified and tested with different types of cameras to obtain better results. (author)

  16. Foreign body extraction from soft tissue by using CT and fluoroscopic guidance: a new technique

    Energy Technology Data Exchange (ETDEWEB)

    Amoretti, Nicolas; Marcy, Pierre-Yves; Lesbats-Jacquot, Virginie; Fonquerne, Marie-Eve; Maratos, Yvonne [Centre Hospitalier Universitaire de Nice, Radiology Department, Nice (France); Hauger, Olivier [Hopital Pellegrin, Unite d' Imagerie Osteo-articulaire, CHU de Bordeaux (France); Hovorka, Istvan; Boileau, Pascal [Centre Hopitalier Universitaire de Nice, Orthopaedic Department, Nice (France)

    2010-01-15

    We report on a new minimally invasive technique for the retrieval of a surgical pin fragment after accidental migration into the soft tissue of the shoulder in two patients. The technique is performed under local anaesthesia and uses combined CT and fluoroscopic guidance. The materials used were simple, combining a bone biopsy needle and an endoscopy clamp. Pin displacement was confirmed under fluoroscopic guidance and the clamp was used to withdraw the pin to the cutaneous entry point under CT (step-by-step) guidance. The CT slices provide perfect visualisation of the vascular or nervous structures as well as perfect positioning of the extremity of the trocar relative to the material to be removed. This intervention avoids a second surgical intervention with a longer incision and avoided repeated general anaesthesia. (orig.)

  17. Fluoroscopically guided fallopian tube recanalization with a simplified set of instruments

    International Nuclear Information System (INIS)

    Schmitz-Rode, T.; Guenther, R.W.; Neulen, J.

    2004-01-01

    Purpose: Fluoroscopically guided transcervical fallopian tube recanalization is recognized as an important step in the workup of female infertility. In the present study, a simplified set of recanalization instruments was tested. Materials and Methods: Forty-two women with infertility and sonographically confirmed or suspected uni- or bilateral tubal occlusion were examined. After vaginal placement of a plastic speculum and fixation of a tenaculum, a 4F glide catheter with a 0.89 mm glidewire was advanced transcervically. After documentation of tubal occlusion by hysterosalpingography, the uterotubal junction was catheterized with the same instruments. Under fluoroscopic guidance, the glidewire was negotiated beyond the intramural portion of the tube. Selective salpingography documented the outcome of the recanalization. Results: Hysterosalpingography confirmed tubal occlusions in 26 of 42 patients (in 12 cases unilateral and in 14 cases bilateral). Fallopian tube recanalization was successful in 23 of 26 patients (technical success rate of 88%). The resulting fertility rate was 30% (7/23), without any ectopic pregnancy. Complications such as tubal perforation, infection, or bleeding did not occur. Tubal catheterization was straightforward and smooth in 17/23 cases. For a hyperflexed uterus (6/23), a curved tip of the catheter was helpful in tubal probing. (orig.)

  18. Comparison of MR and fluoroscopic mucous fistulography in the pre-operative evaluation of infants with anorectal malformation: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Jose C.G.; Lotz, Jan W.; Pitcher, Richard D. [Stellenbosch University, Division of Radiodiagnosis, Department of Medical Imaging and Clinical Oncology, Tygerberg Academic Hospital, Cape Town (South Africa); Sidler, Daniel [Stellenbosch University, Division of Pediatric Surgery, Department of Surgical Sciences, Tygerberg Academic Hospital, Cape Town (South Africa)

    2013-08-15

    Anorectal malformations are often associated with rectal pouch fistulas. Surgical correction requires accurate evaluation of the presence and position of such fistulas. Fluoroscopy is currently the chosen modality for the detection of fistulas. The role of MRI is unexplored. To compare the diagnostic accuracy of MR versus fluoroscopic fistulography in the pre-operative evaluation of infants with anorectal malformation. We conducted a pilot study of infants requiring defunctioning colostomy for initial management of anorectal malformation. Dynamic sagittal steady-state free-precession MRI of the pelvis was acquired during introduction of saline into the mucous fistulas. Findings were compared among MR fistulography, fluoroscopic fistulography and intraoperative inspection. Eight children were included. Median age at fistulography was 15 weeks, inter-quartile range 13-20 weeks; all were boys. There was full agreement among MR fistulography, fluoroscopic fistulography and surgical findings. The pilot data suggest that MR fistulography is promising in the pre-operative evaluation of children with anorectal malformation. (orig.)

  19. Radiotherapy verification film for estimating cumulative entrance skin exposure for fluoroscopic examinations

    International Nuclear Information System (INIS)

    Geise, R.A.; Ansel, H.J.

    1990-01-01

    Measurement of skin entrance exposures during fluoroscopic procedures is complicated by the use of automatic exposure control devices and the presence of contrast media. Due to variability in positioning spot films from patient to patient, standard dosimeters, such as thermoluminescent, cannot be properly placed on the skin prior to examination. Prepackaged film of the type used for portal verification in radiation therapy held next to the patient's skin in a specially modified patient examination gown was found to be useful for determining the entrance skin exposure from both fluoroscopy and spot films during air contrast barium enema exams. The usable sensitivity range of this film has been found satisfactory for exposure measurements at exposures and kVps typically used for gastrointestinal fluoroscopic procedures. Errors in exposure estimates due to changes in film speed and contrast with kVp are less than 5% for the range of kVps used. Errors from variations in beam quality due to the adjacency of scattering material are approximately 5%. Entrance exposures determined with film agreed with those determined from TLD measurements to within 21%, with an average difference of 9%

  20. Development of a method to calculate organ doses for the upper gastrointestinal fluoroscopic examination

    International Nuclear Information System (INIS)

    Suleiman, O.H.

    1989-01-01

    A method was developed to quantitatively measure the upper gastrointestinal fluoroscopic examination in order to calculate organ doses. The dynamic examination was approximated with a set of discrete x-ray fields. Once the examination was segmented into discrete x-ray fields appropriate organ dose tables were generated using an existing computer program for organ dose calculations. This, along with knowledge of the radiation exposures associated with each of the fields, enabled the calculation of organ doses for the entire dynamic examination. The protocol involves videotaping the examination while fluoroscopic technique factors, tube current and tube potential, are simultaneously recorded on the audio tracks of the videotape. Subsequent analysis allows the dynamic examination to be segmented into a series of discrete x-ray fields uniquely defined by field size, projection, and anatomical region. The anatomical regions associated with the upper gastrointestinal examination were observed to be the upper, middle, and lower esophagus, the gastroesophageal junction, the stomach, and the duodenum

  1. Effectiveness of Fluoroscopic and US - Guided Percutaneous Catheter Drainage for Iliopsoas Abscess through the Anterolateral Transabdominal Approach

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Ho Cheol; Shin, Tae Beom; Park, Mee Jung; Kim, Ji Eun; Choi, Hye Young; Bae, Kyung Soo; Choi, Dae Seob; Na, Jae Boem; Jeong, Seong Hoon [Gyeongsang National University Hospital, College of Medicine, Jinju (Korea, Republic of)

    2011-02-15

    We evaluated the effectiveness of performing fluoroscopic and ultrasonography guided percutaneous catheter drainage (PCD) through the anterolateral transabdominal approach for treating iliopsoas abscess. From January 2008 to December 2009, fluoroscopic and US-guided PCD through the anterolateral transabdominal approach was performed on sixteen iliopsoas abscesses of fourteen patients (7 males and 7 females; mean age: 63 years; age range: 30-87 years). Six abscesses were on the right side and ten abscesses were on the left side. The location of the abscesses were the psoas muscle (n=7), the iliacus muscle (n=7) and the iliopsoas muscle (n=2). All the procedures were performed under fluoroscopy and US guidance in the angiography room. The clinical findings before and after the procedure, the duration of catheter insertion and the procedure-related complications were evaluated. 15 out of the 16 iliopsoas abscesses were effectively treated. The duration of catheter insertion was 5- 27 days (mean: 14.6) days. No patient had significant complications during or after drainage. One patient died of uncontrolled diabetes complications and shock on the 9th day after percutaneous catheter drainage. One recurrence was noted 5 months after removal of the catheter. This patient underwent aspiration and antibiotic treatment for this lesion and the patient improved. Fluoroscopic and US-guided PCD for iliopsoas abscess through the anterolateral transabdominal approach is an effective and safe procedure

  2. Fluoroscopically guided percutaneous jejunostomy: outcomes in 25 consecutive patients

    International Nuclear Information System (INIS)

    Yang, Z.Q.; Shin, J.H.; Song, H.-Y.; Kwon, J.H.; Kim, J.-W.; Kim, K.R.; Kim, J.-H.

    2007-01-01

    Aim: To assess the feasibility and safety of fluoroscopically guided percutaneous jejunostomy. Material and methods: Between May 1999 and August 2006 percutaneous jejunostomy was attempted in 25 patients. A 5 F vascular catheter (n = 20) or a 7.5 F multifunctional coil catheter (n = 5) was used to insufflate the jejunum. The distended jejunum was punctured using a 17 G needle (n = 19) or a 21 G Chiba needle (n = 6) with the inserted catheter as a target. A 12 or 14 F loop feeding tube was inserted after serial dilations. The technical success, complications, 30-day mortality, and in-dwelling period of the feeding tube placement were evaluated. Results: The technical success rate was 92% (23/25). Technical failures (n = 2) resulted from the inability to insufflate the jejunum secondary to failure to pass the catheter through a malignant stricture at the oesophagojejunostomy site and thus subsequent puncture of the undistended jejunum failed, or failure to introduce the Neff catheter into the jejunum. Pericatheter leakage with pneumoperitoneum was a complication in three patients (12%) and was treated conservatively. The 30-day mortality was 13% (3/23); however, there was no evidence that these deaths were attributed to the procedure. Except for four patients who were lost to follow-up and two failed cases, 15 of the 19 jejunostomy catheters were removed because of patient death (n = 12) or completion of treatment (n = 3), with a mean and median in-dwelling period of 231 and 87 days, respectively. Conclusions: Fluoroscopically guided percutaneous jejunostomy is a feasible procedure with a high technical success and a low complication rate. In addition to a 17 G needle, a 21 G needle can safely be used to puncture the jejunum

  3. Exposition of the operator's eye lens and efficacy of radiation shielding in fluoroscopically guided interventions

    International Nuclear Information System (INIS)

    Galster, M.; Adamus, R.; Guhl, C.; Uder, M.

    2013-01-01

    Purpose: Efficacy of radiation protection tools for the eye lens dose of the radiologist in fluoroscopic interventions. Materials and Methods: A patient phantom was exposed using a fluoroscopic system. Dose measurements were made at the eye location of the radiologist using an ionization chamber. The setting followed typical fluoroscopic interventions. The reduction of scattered radiation by the equipment-mounted shielding (undercouch drapes and overcouch top) was evaluated. The ceiling-suspended lead acrylic glass screen was tested in scattered radiation generated by a slab phantom. The protective properties of different lead glass goggles and lead acrylic visors were evaluated by thermoluminescence measurements on a head phantom in the primary beam. Results: The exposition of the lens of about 110 to 550 μSv during radiologic interventions is only slightly reduced by the undercouch drapes. Applying the top in addition to the drapes reduces the lens dose by a factor of 2 for PA projections. In 25 LAO the dose is reduced by a factor between 1.2 and 5. The highest doses were measured for AP angulations furthermore the efficacy of the equipment-mounted shielding is minimal. The ceiling-suspended lead screen reduced scatter by a factor of about 30. The lead glass goggles and visors reduced the lens dose up to a factor of 8 to 10. Depending on the specific design, the tested models are less effective especially for radiation from lateral with cranial angulation of the beam. Occasionally the visors even caused an increase of dose. Conclusion: The exposition of the eye lens can be kept below the new occupational limit recommended by the ICRP if the radiation shielding equipment is used consistently. (orig.)

  4. High-speed rotary atherectomy under fluoroscopic and angioscopic guidance

    International Nuclear Information System (INIS)

    Deutsch, L.S.; Ahn, S.S.; Yeatman, L.A.; Marcus, D.R.; Auth, D.P.; Moore, W.S.

    1988-01-01

    This paper describes thirteen stenotic arteries treated by high-speed rotary abrasive burr atherectomy performed in the operating room under fluoroscopic-angioscopic control by a multidisciplinary team consisting of a vascular surgeon, an interventional radiologist, and an interventional cardiologist. Incrementally sized atherectomy burrs were used in each patient (1.75-4.0 mm in diameter). Rotary artherectomy was successful in 11 of 13 arteries ranging from 1 to 40 cm (median, 5 cm) with stenoses ranging from 50% to 99% (median, 90%), which improved to less than 30% in all 11 successfully atherectomized segments. Two early posttreatment failures (intimal dissection, burr shaft disruption), two posttreatment thromboses (unrelated to atherectomy), and two late failures (restenosis) occurred

  5. Percutaneous interventional forceps removal of radiopaque foreign bodies in soft-tissue under fluoroscopic guidance

    International Nuclear Information System (INIS)

    Yang Xiujun; Xing Guangfu; Shi Changwen; Li Wei

    2011-01-01

    Objective: To evaluate the clinical value and limitations of percutaneous interventional forceps retrieval technique under fluoroscopic guidance in removing radiopaque foreign bodies in soft-tissue. Methods: A total of 4 105 consecutive soft-tissue injury patients with radiopaque foreign bodies, encountered in authors' hospital during the period from June 2005 to June 2010, were involved in this study. The diagnosis was confirmed by plain X-ray films in all patients. Additional CT scanning was performed in 1 591 patients, in some of them 3D reconstruction was adopted. With local anesthesia percutaneous interventional forceps retrieval of radiopaque foreign bodies (PIRFB) was carried out under C-arm video-fluoroscopic guidance. Results: Of all patients in this study, 61.34% (2 518/4 105) was treated by PIRFB (study group), and 38.66% (1 587/4 105) was not treated with PIRFB (control group). In study group,the complete and partial curative rate was 95.07% (2 394/2 518) and 4.81% (121/2 518) respectively, and the failure rate was 0.12% (3/2 518). Of 1 587 patients in control group, 25.02% (n=397) left hospital by patient's own reasons and 74.98% (n=1190) was discharged from hospital due to medical or technical reasons. In control group,the foreign objects were close to big vessels in 65.22% (1 035/1 587), large local hematoma was accompanied in 2.90% (46/1 587), associated traumatic pseudoaneurysm was seen in 1.32% (21/1 587) and the foreign objects were glass pieces and the like were found in 5.55% (88/1 587). No serious postoperative complications that required specific therapy, such as bleeding, infection and nerve damage, etc. occurred. CT, especially enhanced CT three-dimensional images, could precisely display the vasculatures nearby the foreign body, which helped make the correct judgment of the removal ability and the operation risk for foreign bodies with interventional procedure. Conclusion: Percutaneous interventional forceps retrieval technique under

  6. Evaluation of methods to produce an image library for automatic patient model localization for dose mapping during fluoroscopically guided procedures

    Science.gov (United States)

    Kilian-Meneghin, Josh; Xiong, Z.; Rudin, S.; Oines, A.; Bednarek, D. R.

    2017-03-01

    The purpose of this work is to evaluate methods for producing a library of 2D-radiographic images to be correlated to clinical images obtained during a fluoroscopically-guided procedure for automated patient-model localization. The localization algorithm will be used to improve the accuracy of the skin-dose map superimposed on the 3D patient- model of the real-time Dose-Tracking-System (DTS). For the library, 2D images were generated from CT datasets of the SK-150 anthropomorphic phantom using two methods: Schmid's 3D-visualization tool and Plastimatch's digitally-reconstructed-radiograph (DRR) code. Those images, as well as a standard 2D-radiographic image, were correlated to a 2D-fluoroscopic image of a phantom, which represented the clinical-fluoroscopic image, using the Corr2 function in Matlab. The Corr2 function takes two images and outputs the relative correlation between them, which is fed into the localization algorithm. Higher correlation means better alignment of the 3D patient-model with the patient image. In this instance, it was determined that the localization algorithm will succeed when Corr2 returns a correlation of at least 50%. The 3D-visualization tool images returned 55-80% correlation relative to the fluoroscopic-image, which was comparable to the correlation for the radiograph. The DRR images returned 61-90% correlation, again comparable to the radiograph. Both methods prove to be sufficient for the localization algorithm and can be produced quickly; however, the DRR method produces more accurate grey-levels. Using the DRR code, a library at varying angles can be produced for the localization algorithm.

  7. Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

    International Nuclear Information System (INIS)

    Fujita, Takeshi; Tanabe, Masahiro; Yamatogi, Shigenari; Shimizu, Kensaku; Matsunaga, Naofumi

    2011-01-01

    The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57–93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 ± 13 (SD) min (range 24–78). The average follow-up time interval was 103 days (range 7–812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

  8. Leaded eyeglasses substantially reduce radiation exposure of the surgeon's eyes during acquisition of typical fluoroscopic views of the hip and pelvis.

    Science.gov (United States)

    Burns, Sean; Thornton, Raymond; Dauer, Lawrence T; Quinn, Brian; Miodownik, Daniel; Hak, David J

    2013-07-17

    Despite recommendations to do so, few orthopaedists wear leaded glasses when performing operative fluoroscopy. Radiation exposure to the ocular lens causes cataracts, and regulatory limits for maximum annual occupational exposure to the eye continue to be revised downward. Using anthropomorphic patient and surgeon phantoms, radiation dose at the surgeon phantom's lens was measured with and without leaded glasses during fluoroscopic acquisition of sixteen common pelvic and hip views. The magnitude of lens dose reduction from leaded glasses was calculated by dividing the unprotected dose by the dose measured behind leaded glasses. On average, the use of leaded glasses reduced radiation to the surgeon phantom's eye by tenfold, a 90% reduction in dose. However, there was widespread variation in the amount of radiation that reached the phantom surgeon's eye among the various radiographic projections we studied. Without leaded glasses, the dose measured at the surgeon's lens varied more than 250-fold among these sixteen different views. In addition to protecting the surgeon's eye from the deleterious effects of radiation, the use of leaded glasses could permit an orthopaedist to perform fluoroscopic views on up to ten times more patients before reaching the annual dose limit of 20 mSv of radiation to the eye recommended by the International Commission on Radiological Protection. Personal safety and adherence to limits of occupational radiation exposure should compel orthopaedists to wear leaded glasses for fluoroscopic procedures if other protective barriers are not in use. Leaded glasses are a powerful tool for reducing the orthopaedic surgeon's lens exposure to radiation during acquisition of common intraoperative fluoroscopic views.

  9. Lung tumor tracking in fluoroscopic video based on optical flow

    International Nuclear Information System (INIS)

    Xu Qianyi; Hamilton, Russell J.; Schowengerdt, Robert A.; Alexander, Brian; Jiang, Steve B.

    2008-01-01

    Respiratory gating and tumor tracking for dynamic multileaf collimator delivery require accurate and real-time localization of the lung tumor position during treatment. Deriving tumor position from external surrogates such as abdominal surface motion may have large uncertainties due to the intra- and interfraction variations of the correlation between the external surrogates and internal tumor motion. Implanted fiducial markers can be used to track tumors fluoroscopically in real time with sufficient accuracy. However, it may not be a practical procedure when implanting fiducials bronchoscopically. In this work, a method is presented to track the lung tumor mass or relevant anatomic features projected in fluoroscopic images without implanted fiducial markers based on an optical flow algorithm. The algorithm generates the centroid position of the tracked target and ignores shape changes of the tumor mass shadow. The tracking starts with a segmented tumor projection in an initial image frame. Then, the optical flow between this and all incoming frames acquired during treatment delivery is computed as initial estimations of tumor centroid displacements. The tumor contour in the initial frame is transferred to the incoming frames based on the average of the motion vectors, and its positions in the incoming frames are determined by fine-tuning the contour positions using a template matching algorithm with a small search range. The tracking results were validated by comparing with clinician determined contours on each frame. The position difference in 95% of the frames was found to be less than 1.4 pixels (∼0.7 mm) in the best case and 2.8 pixels (∼1.4 mm) in the worst case for the five patients studied.

  10. [Exposition of the operator's eye lens and efficacy of radiation shielding in fluoroscopically guided interventions].

    Science.gov (United States)

    Galster, M; Guhl, C; Uder, M; Adamus, R

    2013-05-01

    Efficacy of radiation protection tools for the eye lens dose of the radiologist in fluoroscopic interventions. A patient phantom was exposed using a fluoroscopic system. Dose measurements were made at the eye location of the radiologist using an ionization chamber. The setting followed typical fluoroscopic interventions. The reduction of scattered radiation by the equipment-mounted shielding (undercouch drapes and overcouch top) was evaluated. The ceiling-suspended lead acrylic glass screen was tested in scattered radiation generated by a slab phantom. The protective properties of different lead glass goggles and lead acrylic visors were evaluated by thermoluminescence measurements on a head phantom in the primary beam. The exposition of the lens of about 110 to 550 μSv during radiologic interventions is only slightly reduced by the undercouch drapes. Applying the top in addition to the drapes reduces the lens dose by a factor of 2 for PA projections. In 25°LAO the dose is reduced by a factor between 1.2 and 5. The highest doses were measured for AP angulations furthermore the efficacy of the equipment-mounted shielding is minimal. The ceiling-suspended lead screen reduced scatter by a factor of about 30. The lead glass goggles and visors reduced the lens dose up to a factor of 8 to 10. Depending on the specific design, the tested models are less effective especially for radiation from lateral with cranial angulation of the beam. Occasionally the visors even caused an increase of dose. The exposition of the eye lens can be kept below the new occupational limit recommended by the ICRP if the radiation shielding equipment is used consistently. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Fluoroscopically Guided Extraforaminal Cervical Nerve Root Blocks: Analysis of Epidural Flow of the Injectate with Respect to Needle Tip Position

    Science.gov (United States)

    Shipley, Kyle; Riew, K. Daniel; Gilula, Louis A.

    2013-01-01

    Study Design Retrospective evaluation of consecutively performed fluoroscopically guided cervical nerve root blocks. Objective To describe the incidence of injectate central epidural flow with respect to needle tip position during fluoroscopically guided extraforaminal cervical nerve root blocks (ECNRBs). Methods Between February 19, 2003 and June 11, 2003, 132 consecutive fluoroscopically guided ECNRBs performed with contrast media in the final injected material (injectate) were reviewed on 95 patients with average of 1.3 injections per patient. Fluoroscopic spot images documenting the procedure were obtained as part of standard quality assurance. An independent observer not directly involved in the procedures retrospectively reviewed the images, and the data were placed into a database. Image review was performed to determine optimal needle tip positioning for injectate epidural flow. Results Central epidural injectate flow was obtained in only 28.9% of injections with the needle tip lateral to midline of the lateral mass (zone 2). 83.8% of injectate went into epidural space when the needle tip was medial to midline of the lateral mass (zone 3). 100% of injectate flowed epidurally when the needle tip was medial to or at the medial cortex of the lateral mass (zone 4). There was no statistically significant difference with regards to central epidural flow and the needle tip position on lateral view. Conclusion To ensure central epidural flow with ECNRBs one must be prepared to pass the needle tip medial to midplane of the lateral mass or to medial cortex of the lateral mass. Approximately 16% of ECNRBs with needle tip medial to midline of the lateral mass did not flow into epidural space. One cannot claim a nerve block is an epidural block unless epidural flow of injectate is observed. PMID:24494176

  12. Fluoroscopic extraction of esophageal foreign body

    International Nuclear Information System (INIS)

    Chon, Su Bin; Han, Young Min; Chung, Gyung Ho; Sohn, Myung Hee; Kim, Chong Soo; Choi, Ki Chul; Song, Young Ho; Choi, Yeon Wha

    1993-01-01

    The purpose of this study is to report our 5 year experience with fluoroscopic removal of blunt esophageal foreign body or impacted food in 15 consecutive patients who were referred by endoscopists because they couln't remove it endoscopically. The foreign body or impacted food was a piece of meat, a bean, a badug stone or a beef bone. Thirteen patients had underlying disease (11 of corrosive stricture, 2 of postopertive stricture) but 2 patient did not. We removed the object using one of the following 4 techniques: Basket extraction technique. Foley catheter technique, single balloon technique (dilatation of stenosis for passing the food into the stomach and for the treatment of the stricture as well), double balloon technique (removal of the foregin body by trapping it with two valvuloplasty balloons). Removal was successful in all patients. Esophageal performation occurred in one patient using the sibgle balloon technique, who treated nonoperatively by means of fasting, antibiotics and parenteral alimentation. No procedure related death occurred in these series. In conclusion, fliuroscopic removal of blunt esophageal foreign bodies of impacted food with various techniques is promising alternative to esophagoscopic removal

  13. SU-G-JeP1-11: Feasibility Study of Markerless Tracking Using Dual Energy Fluoroscopic Images for Real-Time Tumor-Tracking Radiotherapy System

    Energy Technology Data Exchange (ETDEWEB)

    Shiinoki, T; Shibuya, K [Yamaguchi University, Ube, Yamaguchi (Japan); Sawada, A [Kyoto college of medical science, Nantan, Kyoto (Japan); Uehara, T; Yuasa, Y; Koike, M; Kawamura, S [Yamaguchi University Hospital, Ube, Yamaguchi (Japan)

    2016-06-15

    Purpose: The new real-time tumor-tracking radiotherapy (RTRT) system was installed in our institution. This system consists of two x-ray tubes and color image intensifiers (I.I.s). The fiducial marker which was implanted near the tumor was tracked using color fluoroscopic images. However, the implantation of the fiducial marker is very invasive. Color fluoroscopic images enable to increase the recognition of the tumor. However, these images were not suitable to track the tumor without fiducial marker. The purpose of this study was to investigate the feasibility of markerless tracking using dual energy colored fluoroscopic images for real-time tumor-tracking radiotherapy system. Methods: The colored fluoroscopic images of static and moving phantom that had the simulated tumor (30 mm diameter sphere) were experimentally acquired using the RTRT system. The programmable respiratory motion phantom was driven using the sinusoidal pattern in cranio-caudal direction (Amplitude: 20 mm, Time: 4 s). The x-ray condition was set to 55 kV, 50 mA and 105 kV, 50 mA for low energy and high energy, respectively. Dual energy images were calculated based on the weighted logarithmic subtraction of high and low energy images of RGB images. The usefulness of dual energy imaging for real-time tracking with an automated template image matching algorithm was investigated. Results: Our proposed dual energy subtraction improve the contrast between tumor and background to suppress the bone structure. For static phantom, our results showed that high tracking accuracy using dual energy subtraction images. For moving phantom, our results showed that good tracking accuracy using dual energy subtraction images. However, tracking accuracy was dependent on tumor position, tumor size and x-ray conditions. Conclusion: We indicated that feasibility of markerless tracking using dual energy fluoroscopic images for real-time tumor-tracking radiotherapy system. Furthermore, it is needed to investigate the

  14. Reduction of radiation exposure while maintaining high-quality fluoroscopic images during interventional cardiology using novel x-ray tube technology with extra beam filtering.

    Science.gov (United States)

    den Boer, A; de Feyter, P J; Hummel, W A; Keane, D; Roelandt, J R

    1994-06-01

    Radiographic technology plays an integral role in interventional cardiology. The number of interventions continues to increase, and the associated radiation exposure to patients and personnel is of major concern. This study was undertaken to determine whether a newly developed x-ray tube deploying grid-switched pulsed fluoroscopy and extra beam filtering can achieve a reduction in radiation exposure while maintaining fluoroscopic images of high quality. Three fluoroscopic techniques were compared: continuous fluoroscopy, pulsed fluoroscopy, and a newly developed high-output pulsed fluoroscopy with extra filtering. To ascertain differences in the quality of images and to determine differences in patient entrance and investigator radiation exposure, the radiated volume curve was measured to determine the required high voltage levels (kVpeak) for different object sizes for each fluoroscopic mode. The fluoroscopic data of 124 patient procedures were combined. The data were analyzed for radiographic projections, image intensifier field size, and x-ray tube kilovoltage levels (kVpeak). On the basis of this analysis, a reference procedure was constructed. The reference procedure was tested on a phantom or dummy patient by all three fluoroscopic modes. The phantom was so designed that the kilovoltage requirements for each projection were comparable to those needed for the average patient. Radiation exposure of the operator and patient was measured during each mode. The patient entrance dose was measured in air, and the operator dose was measured by 18 dosimeters on a dummy operator. Pulsed compared with continuous fluoroscopy could be performed with improved image quality at lower kilovoltages. The patient entrance dose was reduced by 21% and the operator dose by 54%. High-output pulsed fluoroscopy with extra beam filtering compared with continuous fluoroscopy improved the image quality, lowered the kilovoltage requirements, and reduced the patient entrance dose by 55% and

  15. MO-F-CAMPUS-I-02: Occupational Conceptus Doses From Fluoroscopically-Guided Interventional Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Damilakis, J; Perisinakis, K; Solomou, G [University of Crete (Greece); Stratakis, J [University of Crete, Heraklion, Crete (Greece)

    2015-06-15

    Purpose: The aim of this method was to provide dosimetric data on conceptus dose for the pregnant employee who participates in fluoroscopically-guided interventional procedures. Methods: Scattered air-kerma dose rates were obtained for 17 fluoroscopic projections involved in interventional procedures. These projections were simulated on an anthropomorphic phantom placed on the examination table supine. The operating theater was divided into two grids relative to the long table sides. Each grid consisted of 33 cells spaced 0.50 m apart. During the simulated exposures, at each cell, scatter air-kerma rate was measured at 110 cm from the floor i.e. at the height of the waist of the pregnant worker. Air-kerma rates were divided by the dose area product (DAP) rate of each exposure to obtain normalized data. For each projection, measurements were performed for 3 kVp and 3 filtration values i.e. for 9 different x-ray spectra. All measurements were performed by using a modern C-arm angiographic system (Siemens Axiom Artis, Siemens, Germany) and a radiation meter equipped with an ionization chamber. Results: The results consist of 153 iso-dose maps, which show the spatial distribution of DAP-normalized scattered air-kerma doses at the waist level of a pregnant worker. Conceptus dose estimation is possible using air-kerma to embryo/fetal dose conversion coefficients published in a previous study (J Cardiovasc Electrophysiol, Vol. 16, pp. 1–8, July 2005). Using these maps, occupationally exposed pregnant personnel may select a working position for a certain projection that keeps abdominal dose as low as reasonably achievable. Taking into consideration the regulatory conceptus dose limit for occupational exposure, determination of the maximum workload allowed for the pregnant personnel is also possible. Conclusion: Data produced in this work allow for the anticipation of conceptus dose and the determination of the maximum workload for a pregnant worker from any

  16. MO-F-CAMPUS-I-02: Occupational Conceptus Doses From Fluoroscopically-Guided Interventional Procedures

    International Nuclear Information System (INIS)

    Damilakis, J; Perisinakis, K; Solomou, G; Stratakis, J

    2015-01-01

    Purpose: The aim of this method was to provide dosimetric data on conceptus dose for the pregnant employee who participates in fluoroscopically-guided interventional procedures. Methods: Scattered air-kerma dose rates were obtained for 17 fluoroscopic projections involved in interventional procedures. These projections were simulated on an anthropomorphic phantom placed on the examination table supine. The operating theater was divided into two grids relative to the long table sides. Each grid consisted of 33 cells spaced 0.50 m apart. During the simulated exposures, at each cell, scatter air-kerma rate was measured at 110 cm from the floor i.e. at the height of the waist of the pregnant worker. Air-kerma rates were divided by the dose area product (DAP) rate of each exposure to obtain normalized data. For each projection, measurements were performed for 3 kVp and 3 filtration values i.e. for 9 different x-ray spectra. All measurements were performed by using a modern C-arm angiographic system (Siemens Axiom Artis, Siemens, Germany) and a radiation meter equipped with an ionization chamber. Results: The results consist of 153 iso-dose maps, which show the spatial distribution of DAP-normalized scattered air-kerma doses at the waist level of a pregnant worker. Conceptus dose estimation is possible using air-kerma to embryo/fetal dose conversion coefficients published in a previous study (J Cardiovasc Electrophysiol, Vol. 16, pp. 1–8, July 2005). Using these maps, occupationally exposed pregnant personnel may select a working position for a certain projection that keeps abdominal dose as low as reasonably achievable. Taking into consideration the regulatory conceptus dose limit for occupational exposure, determination of the maximum workload allowed for the pregnant personnel is also possible. Conclusion: Data produced in this work allow for the anticipation of conceptus dose and the determination of the maximum workload for a pregnant worker from any

  17. Selecting appropriate gastroenteric contrast media for diagnostic fluoroscopic imaging in infants and children: a practical approach.

    Science.gov (United States)

    Callahan, Michael J; Talmadge, Jennifer M; MacDougall, Robert D; Kleinman, Patricia L; Taylor, George A; Buonomo, Carlo

    2017-04-01

    In our experience, questions about the appropriate use of enteric contrast media for pediatric fluoroscopic studies are common. The purpose of this article is to provide a comprehensive review of enteric contrast media used for pediatric fluoroscopy, highlighting the routine use of these media at a large tertiary care pediatric teaching hospital.

  18. SU-D-209-01: Can Fluoroscopic Air-Kerma Rates Be Reliably Measured with Solid-State Meters?

    International Nuclear Information System (INIS)

    Feng, C; Thai, L; Wagner, L; Ozus, B

    2016-01-01

    Purpose: Ionization chambers remain the standard for calibration of air-kerma rate measuring devices. Despite their strong energy-dependent response, solid state radiation detectors are increasingly used, primarily due to their efficiency in making standardized measurements. To test the reliability of these devices in measuring air-kerma rates, we compared ion chambers measurements with solid-state measurements for various mobile fluoroscopes operated at different beam qualities and air-kerma rates. Methods: Six mobile fluoroscopes (GE OEC models 9800 and 9900) were used to generate test beams. Using various field sizes and dose rate controls, copper attenuators and a lead attenuator were placed at the image receptor in varying combinations to generate a range of air-kerma rates. Air-kerma rates at 30 centimeters from the image receptors were measured using two 6-cm"3 ion chambers with electrometers (Radcal, models 1015 and 9015) and two with solid state detectors (Unfors Xi and Raysafe X2). No error messages occurred during measurements. However, about two months later, one solid-state device stopped working and was replaced by the manufacturer. Two out of six mobile fluoroscopic units were retested with the replacement unit. Results: Generally, solid state and ionization chambers agreed favorably well, with two exceptions. Before replacement of the detector, the Xi meter when set in the “RF High” mode deviated from ion chamber readings by factors of 2 and 10 with no message indicating error in measurement. When set in the “RF Low” mode, readings were within −4% to +3%. The replacement Xi detector displayed messages alerting the user when settings were not compatible with air-kerma rates. Conclusion: Air-kerma rates can be measured favorably well using solid-state devices, but users must be aware of the possibility that readings can be grossly in error with no discernible indication for the deviation.

  19. SU-D-209-01: Can Fluoroscopic Air-Kerma Rates Be Reliably Measured with Solid-State Meters?

    Energy Technology Data Exchange (ETDEWEB)

    Feng, C; Thai, L; Wagner, L [The University of Texas Health Science Center at Houston, Houston, TX (United States); Ozus, B [CHI St Luke’s Health, Baylor St Luke’s Medical Center, Houston, TX (United States)

    2016-06-15

    Purpose: Ionization chambers remain the standard for calibration of air-kerma rate measuring devices. Despite their strong energy-dependent response, solid state radiation detectors are increasingly used, primarily due to their efficiency in making standardized measurements. To test the reliability of these devices in measuring air-kerma rates, we compared ion chambers measurements with solid-state measurements for various mobile fluoroscopes operated at different beam qualities and air-kerma rates. Methods: Six mobile fluoroscopes (GE OEC models 9800 and 9900) were used to generate test beams. Using various field sizes and dose rate controls, copper attenuators and a lead attenuator were placed at the image receptor in varying combinations to generate a range of air-kerma rates. Air-kerma rates at 30 centimeters from the image receptors were measured using two 6-cm{sup 3} ion chambers with electrometers (Radcal, models 1015 and 9015) and two with solid state detectors (Unfors Xi and Raysafe X2). No error messages occurred during measurements. However, about two months later, one solid-state device stopped working and was replaced by the manufacturer. Two out of six mobile fluoroscopic units were retested with the replacement unit. Results: Generally, solid state and ionization chambers agreed favorably well, with two exceptions. Before replacement of the detector, the Xi meter when set in the “RF High” mode deviated from ion chamber readings by factors of 2 and 10 with no message indicating error in measurement. When set in the “RF Low” mode, readings were within −4% to +3%. The replacement Xi detector displayed messages alerting the user when settings were not compatible with air-kerma rates. Conclusion: Air-kerma rates can be measured favorably well using solid-state devices, but users must be aware of the possibility that readings can be grossly in error with no discernible indication for the deviation.

  20. Percutaneous Transhepatic Drainage of Inaccessible Abdominal Abscesses Following Abdominal Surgery Under Real-Time CT-Fluoroscopic Guidance

    International Nuclear Information System (INIS)

    Yamakado, Koichiro; Takaki, Haruyuki; Nakatsuka, Atsuhiro; Kashima, Masataka; Uraki, Junji; Yamanaka, Takashi; Takeda, Kan

    2010-01-01

    This study evaluated the safety, feasibility, and clinical utility of transhepatic drainage of inaccessible abdominal abscesses retrospectively under real-time computed tomographic (CT) guidance. For abdominal abscesses, 12 consecutive patients received percutaneous transhepatic drainage. Abscesses were considered inaccessible using the usual access route because they were surrounded by the liver and other organs. The maximum diameters of abscesses were 4.6-9.5 cm (mean, 6.7 ± 1.4 cm). An 8-Fr catheter was advanced into the abscess cavity through the liver parenchyma using real-time CT fluoroscopic guidance. Safety, feasibility, procedure time, and clinical utility were evaluated. Drainage catheters were placed with no complications in abscess cavities through the liver parenchyma in all patients. The mean procedure time was 18.8 ± 9.2 min (range, 12-41 min). All abscesses were drained. They shrank immediately after catheter placement. In conclusions, this transhepatic approach under real-time CT fluoroscopic guidance is a safe, feasible, and useful technique for use of drainage of inaccessible abdominal abscesses.

  1. The need for using fluoroscopic guidance to obtain gastric biopsies when in search of Helicobacter pylori with a nonendoscopic method

    International Nuclear Information System (INIS)

    Bender, Greg N.; Mullins, Daniel J.; Makuch, Richard S.

    1999-01-01

    Purpose: Nonendoscopic, fluoroscopic biopsy of the gastric mucosa, following barium examination of the stomach, has gained attention with its ease of performance and cost savings potential over endoscopy. Endoscopic research concerning the efficacy of biopsy sites has revealed an increased sensitivity of antral biopsies over greater curvature biopsies for the detection of Helicobacter pylori. Fluoroscopically guided biopsies of the gastric mucosal are studied to determine whether such a difference between site sensitivity held true. If not, blind biopsy through a nasogastric tube, which traditionally samples only the greater curvature, might prove an even less expensive alternative. Materials and methods: Seventy-two patients underwent nonendoscopic, fluoroscopically guided, mucosal biopsy of both the gastric antrum and the greater curvature of the stomach. Pathologic reports from both sites, using each patient as their own control, are compared to assess site sensitivity in the diagnosis of H. pylori gastritis. Results: The sensitivity for the detection of H. pylori gastritis by antral biopsy is 89% whereas the sensitivity of greater curvature biopsy is 62%. The difference is considered clinically significant at P≤0.05. Conclusions: This study confirms the need for antral biopsies when desiring a nonendoscopic approach to gastric mucosal sampling, in order to obtain a reasonable yield of data in dyspeptic patients with H. pylori gastritis. Blind techniques cannot reliably reach the antrum. Fluoroscopy can, and remains a less expensive alternative to endoscopy

  2. The need for using fluoroscopic guidance to obtain gastric biopsies when in search of Helicobacter pylori with a nonendoscopic method

    Energy Technology Data Exchange (ETDEWEB)

    Bender, Greg N.; Mullins, Daniel J.; Makuch, Richard S

    1999-12-01

    Purpose: Nonendoscopic, fluoroscopic biopsy of the gastric mucosa, following barium examination of the stomach, has gained attention with its ease of performance and cost savings potential over endoscopy. Endoscopic research concerning the efficacy of biopsy sites has revealed an increased sensitivity of antral biopsies over greater curvature biopsies for the detection of Helicobacter pylori. Fluoroscopically guided biopsies of the gastric mucosal are studied to determine whether such a difference between site sensitivity held true. If not, blind biopsy through a nasogastric tube, which traditionally samples only the greater curvature, might prove an even less expensive alternative. Materials and methods: Seventy-two patients underwent nonendoscopic, fluoroscopically guided, mucosal biopsy of both the gastric antrum and the greater curvature of the stomach. Pathologic reports from both sites, using each patient as their own control, are compared to assess site sensitivity in the diagnosis of H. pylori gastritis. Results: The sensitivity for the detection of H. pylori gastritis by antral biopsy is 89% whereas the sensitivity of greater curvature biopsy is 62%. The difference is considered clinically significant at P{<=}0.05. Conclusions: This study confirms the need for antral biopsies when desiring a nonendoscopic approach to gastric mucosal sampling, in order to obtain a reasonable yield of data in dyspeptic patients with H. pylori gastritis. Blind techniques cannot reliably reach the antrum. Fluoroscopy can, and remains a less expensive alternative to endoscopy.

  3. Lower radiation burden in state of the art fluoroscopic cystography compared to direct isotope cystography in children.

    Science.gov (United States)

    Haid, Bernhard; Becker, Tanja; Koen, Mark; Berger, Christoph; Langsteger, Werner; Gruy, Bernhard; Putz, Ernst; Haid, Stephanie; Oswald, Josef

    2015-02-01

    Both, fluoroscopic voiding cystourethrography (fVCUG) and direct isotope cystography (DIC) are diagnostic tools commonly used in pediatric urology. Both methods can detect vesicoureteral reflux (VUR) with a high sensitivity. Whilst the possibility to depict anatomical details and important structures as for instance the urethra in boys or the detailed calyceal anatomy are advantages of fVCUG, a lower radiation burden is thought to be the main advantage of DIC. In the last decade, however, a rapid technical evolution has occurred in fluoroscopy by implementing digital grid-controlled, variable rate, pulsed acquisition technique. As documented in literature this led to a substantial decrease in radiation burden conferred during fVCUGs. To question the common belief that direct isotope cystography confers less radiation burden compared to state of the art fluoroscopic voiding cystography. Radiation burden of direct isotope cystography in 92 children and in additional 7 children after an adaption of protocol was compared to radiation burden of fluoroscopic voiding cystourethrography in 51. The examinations were performed according to institutional protocols. For calculation of mean effective radiation dose [mSv] for either method published physical models correcting for age and sex were used. For DIC the model published by Stabin et al., 1998 was applied, for fVCUG two different physical models were used (Schultz et al., 1999, Lee et al., 2009). The radiation burden conferred by direct isotope cystography was significantly higher as for fluoroscopic voiding cystourethrography. The mean effective radiation dose for direct isotope cystography accounted to 0.23 mSv (± 0.34 m, median 0.085 mSv) compared to 0.015 mSv (± 0.013, median 0.008 mSv, model by Schultz et al.) - 0.024 mSv (± 0.018, median 0.018 mSv, model by Lee et al.) for fluoroscopic voiding cystourethrography. After a protocol adaption to correct for a longer examination time in DIC that was caused by

  4. Under digital fluoroscopic guidance multiple-point injection with absolute alcohol and pinyangmycin for the treatment of superficial venous malformations

    International Nuclear Information System (INIS)

    Yang Ming; Xiao Gang; Peng Youlin

    2010-01-01

    Objective: to investigate the therapeutic efficacy of multiple-point injection with absolute alcohol and pinyangmycin under digital fluoroscopic guidance for superficial venous malformations. Methods: By using a disposal venous transfusion needle the superficial venous malformation was punctured and then contrast media lohexol was injected in to visualize the tumor body, which was followed by the injection of ethanol and pinyangmycin when the needle was confirmed in the correct position. The procedure was successfully performed in 31 patients. The clinical results were observed and analyzed. Results: After one treatment complete cure was achieved in 21 cases and marked effect was obtained in 8 cases, with a total effectiveness of 93.5%. Conclusion: Multiple-point injection with ethanol and pinyangmycin under digital fluoroscopic guidance is an effective and safe technique for the treatment of superficial venous malformations, especially for the lesions that are deeply located and ill-defined. (authors)

  5. Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts in the treatment of acute malignant colorectal obstruction.

    Science.gov (United States)

    Kim, Honsoul; Kim, Seung Hyoung; Choi, Sun Young; Lee, Kwang-Hun; Won, Jong Yoon; Lee, Do Yun; Lee, Jong Tae

    2008-12-01

    To evaluate the technical feasibility and clinical effectiveness of fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for acute malignant colorectal obstruction. Radiologic images and clinical reports of 42 patients (22 men, 20 women; age range, 28-93 years; median age, 65.5 years) who underwent fluoroscopically guided colorectal stent insertion without endoscopic assistance for acute malignant obstruction were reviewed retrospectively. Eighteen patients received bare stents as a bridge to surgery. Twenty-four patients received 27 insertions of either a bare stent (n = 15) or a stent-graft (n = 12) for palliation. The obstruction was located in the rectum (n = 8), sigmoid (n = 17), descending colon (n = 8), splenic flexure (n = 3), and transverse colon (n = 6). Clinical success, defined as more than 50% dilatation of the stent with subsequent symptomatic improvement, was achieved in 41 of the 42 patients (98%). No major procedure-related complications occurred. Minor complications occurred in eight of the 45 procedures (18%). No perioperative mortalities occurred within 1 month after surgery. In the palliative group, the median stent patency was 62 days (range, 0-1,014 days). There was no statistically significant difference in stent patency between the bare stents (range, 0-855 days; median, 68 days) and stent-grafts (range, 1-1,014 days; median, 81 days). Fluoroscopically guided placement of self-expandable metallic stents and stent-grafts for the relief of acute malignant colorectal obstruction was technically feasible without endoscopic assistance-even in lesions proximal to the splenic flexure and transverse colon-and clinically effective in both bridge to surgery and palliative management.

  6. Stent placement under fluoroscopic monitoring and endoscopic direct vision for the treatment of malignant gastroduodenal obstruction: a report of 47 cases

    International Nuclear Information System (INIS)

    Zhang Baoyang; Li Weiping; Jiang Haosheng; Liu Shiyi; Hu Yi

    2009-01-01

    Objective: To discuss the operational technique and clinical effect of metallic stent placement in treating malignant gastroduodenal obstruction. Methods: Metallic stent placement under fluoroscopic monitoring and endoscopic direct vision was performed in 47 patients with malignant gastroduodenal obstruction. A total of 54 metallic stents was used. Results: The procedure was successfully completed in all 47 patients. During the follow-up period, all the patients could take liquid or ordinary diet and were markedly relived of vomiting. The living quality was much improved and no serious complications occurred. Conclusion: Under fluoroscopic monitoring and endoscopic direct vision, stent placement is a safe, effective, technically-simple and time-saving procedure for the treatment of malignant gastroduodenal obstruction with less sufferings to the patient. Therefore, it is definitely worth popularizing this technique in clinical practice. (authors)

  7. Robust fluoroscopic tracking of fiducial markers: exploiting the spatial constraints

    International Nuclear Information System (INIS)

    Li Rui; Sharp, Gregory

    2013-01-01

    Two new fluoroscopic fiducial tracking methods that exploit the spatial relationship among the multiple implanted fiducial to achieve fast, accurate and robust tracking are proposed in this paper. The spatial relationship between multiple implanted markers are modeled as Gaussian distributions of their pairwise distances over time. The means and standard deviations of these distances are learned from training sequences, and pairwise distances that deviate from these learned distributions are assigned a low spatial matching score. The spatial constraints are incorporated in two different algorithms: a stochastic tracking method and a detection based method. In the stochastic method, hypotheses of the ‘true’ fiducial position are sampled from a pre-trained respiration motion model. Each hypothesis is assigned an importance value based on image matching score and spatial matching score. Learning the parameters of the motion model is needed in addition to learning the distribution parameters of the pairwise distances in the proposed stochastic tracking approach. In the detection based method, a set of possible marker locations are identified by using a template matching based fiducial detector. The best location is obtained by optimizing the image matching score and spatial matching score through non-serial dynamic programming. In this detection based approach, there is no need to learn the respiration motion model. The two proposed algorithms are compared with a recent work using a multiple hypothesis tracking (MHT) algorithm which is denoted by MHT, Tang et al (2007 Phys. Med. Biol. 52 4081–98). Phantom experiments were performed using fluoroscopic videos captured with known motion relative to an anthropomorphic phantom. The patient experiments were performed using a retrospective study of 16 fluoroscopic videos of liver cancer patients with implanted fiducials. For the motion phantom data sets, the detection based approach has the smallest tracking error (

  8. Characterization of a high-elbow, fluoroscopic electronic portal imaging device for portal dosimetry

    International Nuclear Information System (INIS)

    Boer, J.C.J. de; Visser, A.G.

    2000-01-01

    The application of a newly developed fluoroscopic (CCD-camera based) electronic portal imaging device (EPID) in portal dosimetry is investigated. A description of the EPID response to dose is presented in terms of stability, linearity and optical cross-talk inside the mechanical structure. The EPID has a relatively large distance (41 cm on-axis) between the fluorescent screen and the mirror (high-elbow), which results in cross-talk with properties quite different from that of the low-elbow fluoroscopic EPIDs that have been studied in the literature. In contrast with low-elbow systems, the maximum cross-talk is observed for points of the fluorescent screen that have the largest distance to the mirror, which is explained from the geometry of the system. An algorithm to convert the images of the EPID into portal dose images (PDIs) is presented. The correction applied for cross-talk is a position-dependent additive operation on the EPID image pixel values, with a magnitude that depends on a calculated effective field width. Deconvolution with a point spread function, as applied for low-elbow systems, is not required. For a 25 MV beam, EPID PDIs and ionization chamber measurements in the EPID detector plane were obtained behind an anthropomorphic phantom and a homogeneous absorber for various field shapes. The difference in absolute dose between the EPID and ionization chamber measurements, averaged over the four test fields presented in this paper, was 0.1±0.5% (1 SD) over the entire irradiation field, with no deviation larger than 2%. (author)

  9. Accurate 3D kinematic measurement of temporomandibular joint using X-ray fluoroscopic images

    Science.gov (United States)

    Yamazaki, Takaharu; Matsumoto, Akiko; Sugamoto, Kazuomi; Matsumoto, Ken; Kakimoto, Naoya; Yura, Yoshiaki

    2014-04-01

    Accurate measurement and analysis of 3D kinematics of temporomandibular joint (TMJ) is very important for assisting clinical diagnosis and treatment of prosthodontics and orthodontics, and oral surgery. This study presents a new 3D kinematic measurement technique of the TMJ using X-ray fluoroscopic images, which can easily obtain the TMJ kinematic data in natural motion. In vivo kinematics of the TMJ (maxilla and mandibular bone) is determined using a feature-based 2D/3D registration, which uses beads silhouette on fluoroscopic images and 3D surface bone models with beads. The 3D surface models of maxilla and mandibular bone with beads were created from CT scans data of the subject using the mouthpiece with the seven strategically placed beads. In order to validate the accuracy of pose estimation for the maxilla and mandibular bone, computer simulation test was performed using five patterns of synthetic tantalum beads silhouette images. In the clinical applications, dynamic movement during jaw opening and closing was conducted, and the relative pose of the mandibular bone with respect to the maxilla bone was determined. The results of computer simulation test showed that the root mean square errors were sufficiently smaller than 1.0 mm and 1.0 degree. In the results of clinical application, during jaw opening from 0.0 to 36.8 degree of rotation, mandibular condyle exhibited 19.8 mm of anterior sliding relative to maxillary articular fossa, and these measurement values were clinically similar to the previous reports. Consequently, present technique was thought to be suitable for the 3D TMJ kinematic analysis.

  10. Fluoroscopically guided closed reduction and internal fixation of fractures of the lateral portion of the humeral condyle: prospective clinical study of the technique and results in ten dogs.

    Science.gov (United States)

    Cook, J L; Tomlinson, J L; Reed, A L

    1999-01-01

    To report a technique for fluoroscopically guided closed reduction with internal fixation of fractures of the lateral portion of the humeral condyle (FLHC) and determine the long-term results in 10 clinical cases. Prospective clinical case study. Ten dogs with 11 fractures. Fractures of the lateral portion of the humeral condyle were stabilized with transcondylar screws and Kirschner wires. Closed reduction and implant placement were achieved using intraoperative fluoroscopic guidance. After fracture repair, postoperative radiographs were evaluated for articular alignment and implant placement. Dogs were evaluated after surgery by means of lameness scores, elbow range of motion (ROM), radiographic assessment, and owner evaluation of function. Postoperative reduction was considered anatomic in 6 fractures with all other fractures having ROM values between affected and unaffected elbows. All of the dogs in this study regained 90-100% of full function, based on owner assessment. Fluoroscopic guidance for closed reduction and internal fixation of FLHC in dogs is an effective technique.

  11. WE-G-207-06: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Physical Phantom and Clinical Patient Images

    International Nuclear Information System (INIS)

    Dhou, S; Cai, W; Hurwitz, M; Rottmann, J; Myronakis, M; Cifter, F; Berbeco, R; Lewis, J; Williams, C; Mishra, P; Ionascu, D

    2015-01-01

    Purpose: Respiratory-correlated cone-beam CT (4DCBCT) images acquired immediately prior to treatment have the potential to represent patient motion patterns and anatomy during treatment, including both intra- and inter-fractional changes. We develop a method to generate patient-specific motion models based on 4DCBCT images acquired with existing clinical equipment and used to generate time varying volumetric images (3D fluoroscopic images) representing motion during treatment delivery. Methods: Motion models are derived by deformably registering each 4DCBCT phase to a reference phase, and performing principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated by optimizing the resulting PCA coefficients iteratively through comparison of the cone-beam projections simulating kV treatment imaging and digitally reconstructed radiographs generated from the motion model. Patient and physical phantom datasets are used to evaluate the method in terms of tumor localization error compared to manually defined ground truth positions. Results: 4DCBCT-based motion models were derived and used to generate 3D fluoroscopic images at treatment time. For the patient datasets, the average tumor localization error and the 95th percentile were 1.57 and 3.13 respectively in subsets of four patient datasets. For the physical phantom datasets, the average tumor localization error and the 95th percentile were 1.14 and 2.78 respectively in two datasets. 4DCBCT motion models are shown to perform well in the context of generating 3D fluoroscopic images due to their ability to reproduce anatomical changes at treatment time. Conclusion: This study showed the feasibility of deriving 4DCBCT-based motion models and using them to generate 3D fluoroscopic images at treatment time in real clinical settings. 4DCBCT-based motion models were found to account for the 3D non-rigid motion of the patient anatomy during treatment and have the potential

  12. Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor

    International Nuclear Information System (INIS)

    Shirato, Hiroki; Shimizu, Shinichi; Kitamura, Kei; Nishioka, Takeshi; Kagei, Kenji; Hashimoto, Seiko; Aoyama, Hidefumi; Kunieda, Tatsuya; Shinohara, Nobuo; Dosaka-Akita, Hirotoshi; Miyasaka, Kazuo

    2000-01-01

    Purpose: To achieve precise three-dimensional (3D) conformal radiotherapy for mobile tumors, a new radiotherapy system and its treatment planning system were developed and used for clinical practice. Methods and Materials: We developed a linear accelerator synchronized with a fluoroscopic real-time tumor tracking system by which 3D coordinates of a 2.0-mm gold marker in the tumor can be determined every 0.03 second. The 3D relationships between the marker and the tumor at different respiratory phases are evaluated using CT image at each respiratory phase, whereby the optimum phase can be selected to synchronize with irradiation (4D treatment planning). The linac is triggered to irradiate the tumor only when the marker is located within the region of the planned coordinates relative to the isocenter. Results: The coordinates of the marker were detected with an accuracy of ± 1 mm during radiotherapy in the phantom experiment. The time delay between recognition of the marker position and the start or stop of megavoltage X-ray irradiation was 0.03 second. Fourteen patients with various tumors were treated by conformal radiotherapy with a 'tight' planning target volume (PTV) margin. They were surviving without relapse or complications with a median follow-up of 6 months. Conclusion: Fluoroscopic real-time tumor tracking radiotherapy following 4D treatment planning was developed and shown to be feasible to improve the accuracy of the radiotherapy for mobile tumors

  13. The effect of barium temperature on esophageal and castric motility in dogs: a fluoroscopic study

    International Nuclear Information System (INIS)

    Eville, P.; Ackerman, N.

    1984-01-01

    The influence of barium temperature on canine esophageal transit time and gastric motility were studied fluoroscopically. Micropulverized barium sulfate (30% wt/vol) at 35°F, 70°F, and 100°F was given orally to each of five dogs with a minimum of two hours between each temperature. Esophageal transit times ranged from 4 to 9.67 seconds, and gastric contractions average four per minute. Barium temperature had no significant effect on either esophageal transit time or gastric motility

  14. SU-E-J-01: 3D Fluoroscopic Image Estimation From Patient-Specific 4DCBCT-Based Motion Models

    International Nuclear Information System (INIS)

    Dhou, S; Hurwitz, M; Lewis, J; Mishra, P

    2014-01-01

    Purpose: 3D motion modeling derived from 4DCT images, taken days or weeks before treatment, cannot reliably represent patient anatomy on the day of treatment. We develop a method to generate motion models based on 4DCBCT acquired at the time of treatment, and apply the model to estimate 3D time-varying images (referred to as 3D fluoroscopic images). Methods: Motion models are derived through deformable registration between each 4DCBCT phase, and principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated based on cone-beam projections simulating kV treatment imaging. PCA coefficients are optimized iteratively through comparison of these cone-beam projections and projections estimated based on the motion model. Digital phantoms reproducing ten patient motion trajectories, and a physical phantom with regular and irregular motion derived from measured patient trajectories, are used to evaluate the method in terms of tumor localization, and the global voxel intensity difference compared to ground truth. Results: Experiments included: 1) assuming no anatomic or positioning changes between 4DCT and treatment time; and 2) simulating positioning and tumor baseline shifts at the time of treatment compared to 4DCT acquisition. 4DCBCT were reconstructed from the anatomy as seen at treatment time. In case 1) the tumor localization error and the intensity differences in ten patient were smaller using 4DCT-based motion model, possible due to superior image quality. In case 2) the tumor localization error and intensity differences were 2.85 and 0.15 respectively, using 4DCT-based motion models, and 1.17 and 0.10 using 4DCBCT-based models. 4DCBCT performed better due to its ability to reproduce daily anatomical changes. Conclusion: The study showed an advantage of 4DCBCT-based motion models in the context of 3D fluoroscopic images estimation. Positioning and tumor baseline shift uncertainties were mitigated by the 4DCBCT

  15. Estimation of lung shunt fraction from simultaneous fluoroscopic and nuclear images

    Science.gov (United States)

    van der Velden, Sandra; Bastiaannet, Remco; Braat, Arthur J. A. T.; Lam, Marnix G. E. H.; Viergever, Max A.; de Jong, Hugo W. A. M.

    2017-11-01

    Radioembolisation with yttrium-90 (90Y) is increasingly used as a treatment of unresectable liver malignancies. For safety, a scout dose of technetium-99m macroaggregated albumin (99mTc-MAA) is used prior to the delivery of the therapeutic activity to mimic the deposition of 90Y. One-day procedures are currently limited by the lack of nuclear images in the intervention room. To cope with this limitation, an interventional simultaneous fluoroscopic and nuclear imaging device is currently being developed. The purpose of this simulation study was to evaluate the accuracy of estimating the lung shunt fraction (LSF) of the scout dose in the intervention room with this device and compare it against current clinical methods. Methods: A male and female XCAT phantom, both with two respiratory profiles, were used to simulate various LSFs resulting from a scout dose of 150 MBq 99mTc-MAA. Hybrid images were Monte Carlo simulated for breath-hold (5 s) and dynamic breathing (10 frames of 0.5 s) acquisitions. Nuclear images were corrected for attenuation with the fluoroscopic image and for organ overlap effects using a pre-treatment CT-scan. For comparison purposes, planar scintigraphy and mobile gamma camera images (both 300 s acquisition time) were simulated. Estimated LSFs were evaluated for all methods and compared to the phantom ground truth. Results: In the clinically relevant range of 10-20% LSF, hybrid imaging overestimated LSF with approximately 2 percentage points (pp) and 3 pp for the normal and irregular breathing phantoms, respectively. After organ overlap correction, LSF was estimated with a more constant error. Errors in planar scintigraphy and mobile gamma camera imaging were more dependent on LSF, body shape and breathing profile. Conclusion: LSF can be estimated with a constant minor error with a hybrid imaging device. Estimated LSF is highly dependent on true LSF, body shape and breathing pattern when estimated with current clinical methods. The hybrid

  16. Identification of arteries and veins in cerebral angiography fluoroscopic images

    Science.gov (United States)

    Andra Tache, Irina

    2017-11-01

    In the present study a new method for pixels tagging into arteries and veins classes from temporal cerebral angiography is presented. This need comes from the neurosurgeon who is evaluating the fluoroscopic angiography and the magnetic resonance images from the brain in order to locate the fistula of the patients who suffer from arterio-venous malformation. The method includes the elimination of the background pixels from a previous segmentation and the generation of the time intensity curves for each remaining pixel. The later undergo signal processing in order to extract the characteristic parameters needed for applying the k-means clustering algorithm. Some of the parameters are: the phase and the maximum amplitude extracted from the Fourier transform, the standard deviation and the mean value. The tagged classes are represented into images which then are re-classified by an expert into artery and vein pixels.

  17. Closed reduction and fluoroscopic assisted percutaneous pinning of 42 physeal fractures in 37 dogs and 4 cats

    OpenAIRE

    Boekhout-Ta, Christina L; Kim, Stanley E; Corss, Alan R; Pozzi, Antonio; Evans, Richard

    2017-01-01

    OBJECTIVE: To report complications and clinical outcome of dogs and cats that underwent fluoroscopic-assisted percutaneous pinning (FAPP) of physeal fractures. STUDY DESIGN: Retrospective study. ANIMALS: Client-owned dogs (n = 37) and cats (n = 4). MATERIALS AND METHODS: Records (August 2007-August 2014) of physeal fractures treated with FAPP in 3 hospitals were evaluated. Data collected included signalment, fracture characteristics (etiology, location, duration, Salter-Harris classi...

  18. Fluoroscopic gating without implanted fiducial markers for lung cancer radiotherapy based on support vector machines

    International Nuclear Information System (INIS)

    Cui Ying; Dy, Jennifer G; Alexander, Brian; Jiang, Steve B

    2008-01-01

    Various problems with the current state-of-the-art techniques for gated radiotherapy have prevented this new treatment modality from being widely implemented in clinical routine. These problems are caused mainly by applying various external respiratory surrogates. There might be large uncertainties in deriving the tumor position from external respiratory surrogates. While tracking implanted fiducial markers has sufficient accuracy, this procedure may not be widely accepted due to the risk of pneumothorax. Previously, we have developed a technique to generate gating signals from fluoroscopic images without implanted fiducial markers using template matching methods (Berbeco et al 2005 Phys. Med. Biol. 50 4481-90, Cui et al 2007b Phys. Med. Biol. 52 741-55). In this note, our main contribution is to provide a totally different new view of the gating problem by recasting it as a classification problem. Then, we solve this classification problem by a well-studied powerful classification method called a support vector machine (SVM). Note that the goal of an automated gating tool is to decide when to turn the beam ON or OFF. We treat ON and OFF as the two classes in our classification problem. We create our labeled training data during the patient setup session by utilizing the reference gating signal, manually determined by a radiation oncologist. We then pre-process these labeled training images and build our SVM prediction model. During treatment delivery, fluoroscopic images are continuously acquired, pre-processed and sent as an input to the SVM. Finally, our SVM model will output the predicted labels as gating signals. We test the proposed technique on five sequences of fluoroscopic images from five lung cancer patients against the reference gating signal as ground truth. We compare the performance of the SVM to our previous template matching method (Cui et al 2007b Phys. Med. Biol. 52 741-55). We find that the SVM is slightly more accurate on average (1-3%) than

  19. Fluoroscopically guided fallopian tube recanalization with a simplified set of instruments; Durchleuchtungsgesteuerte Eileiter-Rekanalisation mit vereinfachtem Instrumentarium

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz-Rode, T.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Neulen, J. [Technische Hochschule Aachen (Germany). Frauenklinik fuer gynaekologische Endokrinologie und Reproduktionsmedizin

    2004-10-01

    Purpose: Fluoroscopically guided transcervical fallopian tube recanalization is recognized as an important step in the workup of female infertility. In the present study, a simplified set of recanalization instruments was tested. Materials and Methods: Forty-two women with infertility and sonographically confirmed or suspected uni- or bilateral tubal occlusion were examined. After vaginal placement of a plastic speculum and fixation of a tenaculum, a 4F glide catheter with a 0.89 mm glidewire was advanced transcervically. After documentation of tubal occlusion by hysterosalpingography, the uterotubal junction was catheterized with the same instruments. Under fluoroscopic guidance, the glidewire was negotiated beyond the intramural portion of the tube. Selective salpingography documented the outcome of the recanalization. Results: Hysterosalpingography confirmed tubal occlusions in 26 of 42 patients (in 12 cases unilateral and in 14 cases bilateral). Fallopian tube recanalization was successful in 23 of 26 patients (technical success rate of 88%). The resulting fertility rate was 30% (7/23), without any ectopic pregnancy. Complications such as tubal perforation, infection, or bleeding did not occur. Tubal catheterization was straightforward and smooth in 17/23 cases. For a hyperflexed uterus (6/23), a curved tip of the catheter was helpful in tubal probing. (orig.)

  20. Measuring radiation dose to patients undergoing fluoroscopically-guided interventions

    International Nuclear Information System (INIS)

    Lubis, L E; Badawy, M K

    2016-01-01

    The increasing prevalence and complexity of fluoroscopically guided interventions (FGI) raises concern regarding radiation dose to patients subjected to the procedure. Despite current evidence showing the risk to patients from the deterministic effects of radiation (e.g. skin burns), radiation induced injuries remain commonplace. This review aims to increase the awareness surrounding radiation dose measurement for patients undergoing FGI. A review of the literature was conducted alongside previous researches from the authors’ department. Studies pertaining to patient dose measurement, its formalism along with current advances and present challenges were reviewed. Current patient monitoring techniques (using available radiation dosimeters), as well as the inadequacy of accepting displayed dose as patient radiation dose is discussed. Furthermore, advances in real-time patient radiation dose estimation during FGI are considered. Patient dosimetry in FGI, particularly in real time, remains an ongoing challenge. The increasing occurrence and sophistication of these procedures calls for further advances in the field of patient radiation dose monitoring. Improved measuring techniques will aid clinicians in better predicting and managing radiation induced injury following FGI, thus improving patient care. (paper)

  1. Fluoroscopic Analysis of Tibial Translation in Anterior Cruciate Ligament Injured Knees With and Without Bracing During Forward Lunge

    Science.gov (United States)

    Jalali, Maryam; Farahmand, Farzam; Mousavi, Seyed Mohammad Ebrahim; Golestanha, Seyed Ali; Rezaeian, Tahmineh; Shirvani Broujeni, Shahram; Rahgozar, Mehdi; Esfandiarpour, Fateme

    2015-01-01

    Background: Despite several studies with different methods, the effect of functional knee braces on knee joint kinematics is not clear. Direct visualization of joint components through medical imaging modalities may provide the clinicians with more useful information. Objectives: In this study, for the first time in the literature, video fluoroscopy was used to investigate the effect of knee bracing on the sagittal plane kinematics of anterior cruciate ligament (ACL) injured patients. Patients and Methods: For twelve male unilateral ACL deficient subjects, the anterior tibial translation was measured during lunge exercise in non-braced and braced conditions. Fluoroscopic images were acquired from the subjects using a digital fluoroscopy system with a rate of 10 fps. The image of each frame was scaled using a calibration coin and analyzed in AutoCAD environment. The angle between the two lines, tangent to the posterior cortexes of the femoral and tibial shafts was measured as the flexion angle. For the fluoroscopic images associated with 0°, 15°, 30°, 45° and 60° knee flexion angles, the relative anterior-posterior configuration of the tibiofemoral joint was assessed by measuring the position of landmarks on the tibia and femur. Results: Results indicated that the overall anterior translations of the tibia during the eccentric (down) and concentric (up) phases of lunge exercise were 10.4 ± 1.7 mm and 9.0 ± 2.2 mm for non-braced, and 10.1 ± 3.4 mm and 7.4 ± 2.5 mm, for braced conditions, respectively. The difference of the tibial anterior-posterior translation behaviors of the braced and non-braced knees was not statistically significant. Conclusion: Fluoroscopic imaging provides an effective tool to measure the dynamic behavior of the knee joint in the sagittal plane and within the limitations of this study, the pure mechanical stabilizing effect of functional knee bracing is not sufficient to control the anterior tibial translation of the ACL deficient

  2. Fluoroscopic Analysis of Tibial Translation in Anterior Cruciate Ligament Injured Knees With and Without Bracing During Forward Lunge.

    Science.gov (United States)

    Jalali, Maryam; Farahmand, Farzam; Mousavi, Seyed Mohammad Ebrahim; Golestanha, Seyed Ali; Rezaeian, Tahmineh; Shirvani Broujeni, Shahram; Rahgozar, Mehdi; Esfandiarpour, Fateme

    2015-07-01

    Despite several studies with different methods, the effect of functional knee braces on knee joint kinematics is not clear. Direct visualization of joint components through medical imaging modalities may provide the clinicians with more useful information. In this study, for the first time in the literature, video fluoroscopy was used to investigate the effect of knee bracing on the sagittal plane kinematics of anterior cruciate ligament (ACL) injured patients. For twelve male unilateral ACL deficient subjects, the anterior tibial translation was measured during lunge exercise in non-braced and braced conditions. Fluoroscopic images were acquired from the subjects using a digital fluoroscopy system with a rate of 10 fps. The image of each frame was scaled using a calibration coin and analyzed in AutoCAD environment. The angle between the two lines, tangent to the posterior cortexes of the femoral and tibial shafts was measured as the flexion angle. For the fluoroscopic images associated with 0°, 15°, 30°, 45° and 60° knee flexion angles, the relative anterior-posterior configuration of the tibiofemoral joint was assessed by measuring the position of landmarks on the tibia and femur. Results indicated that the overall anterior translations of the tibia during the eccentric (down) and concentric (up) phases of lunge exercise were 10.4 ± 1.7 mm and 9.0 ± 2.2 mm for non-braced, and 10.1 ± 3.4 mm and 7.4 ± 2.5 mm, for braced conditions, respectively. The difference of the tibial anterior-posterior translation behaviors of the braced and non-braced knees was not statistically significant. Fluoroscopic imaging provides an effective tool to measure the dynamic behavior of the knee joint in the sagittal plane and within the limitations of this study, the pure mechanical stabilizing effect of functional knee bracing is not sufficient to control the anterior tibial translation of the ACL deficient patients during lunge exercise.

  3. An exploration of fluoroscopically guided spinal steroid injections in patients with non-specific exercise-related lower-limb pain

    Directory of Open Access Journals (Sweden)

    Leon Neve

    2010-09-01

    Full Text Available Leon Neve1, John Orchard2, Nathan Gibbs3, Willem van Mechelen4, Evert Verhagen4, Ken Sesel5, Ian Burgess6, Brett Hines61VU University, Amsterdam, The Netherlands; 2School of Public Health, University of Sydney, Sydney, NSW, Australia; 3South Sydney Sports Medicine, Sydney, NSW, Australia; 4EMGO, VU University, Amsterdam, The Netherlands; 5Sydney X-ray Centre, Sydney, NSW, Australia; 6Mater Imaging, Sydney, NSW, AustraliaBackground: Fluoroscopically guided lumbar cortisone injections have been proven useful in cases of lower-limb pain caused by lumbar disc prolapse (with evidence levels ll-1/ll-2. These injections are also sometimes used clinically in sports medicine for patients with non-specific exercise-related lower-limb pain, where no prolapse or other obvious cause of nerve-impingement is diagnosed via magnetic resonance imaging (MRI or computed tomography (CT, even though this treatment scenario has not been adequately studied for this last diagnosis.Objectives: To explore whether fluoroscopically guided transforaminal lumbar cortisone injections may be a valid treatment method for non-specific exercise-related lower-limb pain.Study design: Retrospective case series.Methods: Patients were selected from databases at two sports clinics and divided into two groups: Group D, with back-related lower-limb pain and disc prolapse proven on CT or MR; and Group N, with non-specific exercise-related lower-limb pain. Patients were sent a questionnaire regarding: symptoms, improvement, effect of injections, satisfaction, side effects and other used treatments. Outcomes were compared between Group D and N.Results: 153 patients were eligible for the study (Group D: 93/Group N: 60. Eventually 110 patients responded (Group D: 67/Group N: 43. Twelve percent of Group D and 14% of Group N indicated that the injections had fully cured their symptoms. Altogether, 27% of Group D and 24% of Group N were certain the injections had improved their symptoms in the

  4. SU-E-I-42: Normalized Embryo/fetus Doses for Fluoroscopically Guided Pacemaker Implantation Procedures Calculated Using a Monte Carlo Technique

    Energy Technology Data Exchange (ETDEWEB)

    Damilakis, J; Stratakis, J; Solomou, G [University of Crete, Heraklion (Greece)

    2014-06-01

    Purpose: It is well known that pacemaker implantation is sometimes needed in pregnant patients with symptomatic bradycardia. To our knowledge, there is no reported experience regarding radiation doses to the unborn child resulting from fluoroscopy during pacemaker implantation. The purpose of the current study was to develop a method for estimating embryo/fetus dose from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all trimesters of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study. Three mathematical anthropomorphic phantoms representing the average pregnant patient at the first, second and third trimesters of gestation were generated using Bodybuilder software (White Rock science, White Rock, NM). The normalized embryo/fetus dose from the posteroanterior (PA), the 30° left-anterior oblique (LAO) and the 30° right-anterior oblique (RAO) projections were calculated for a wide range of kVp (50–120 kVp) and total filtration values (2.5–9.0 mm Al). Results: The results consist of radiation doses normalized to a) entrance skin dose (ESD) and b) dose area product (DAP) so that the dose to the unborn child from any fluoroscopic technique and x-ray device used can be calculated. ESD normalized doses ranged from 0.008 (PA, first trimester) to 2.519 μGy/mGy (RAO, third trimester). DAP normalized doses ranged from 0.051 (PA, first trimester) to 12.852 μGy/Gycm2 (RAO, third trimester). Conclusion: Embryo/fetus doses from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all stages of gestation can be estimated using the method developed in this study. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)

  5. SU-E-I-42: Normalized Embryo/fetus Doses for Fluoroscopically Guided Pacemaker Implantation Procedures Calculated Using a Monte Carlo Technique

    International Nuclear Information System (INIS)

    Damilakis, J; Stratakis, J; Solomou, G

    2014-01-01

    Purpose: It is well known that pacemaker implantation is sometimes needed in pregnant patients with symptomatic bradycardia. To our knowledge, there is no reported experience regarding radiation doses to the unborn child resulting from fluoroscopy during pacemaker implantation. The purpose of the current study was to develop a method for estimating embryo/fetus dose from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all trimesters of gestation. Methods: The Monte Carlo N-Particle (MCNP) radiation transport code was employed in this study. Three mathematical anthropomorphic phantoms representing the average pregnant patient at the first, second and third trimesters of gestation were generated using Bodybuilder software (White Rock science, White Rock, NM). The normalized embryo/fetus dose from the posteroanterior (PA), the 30° left-anterior oblique (LAO) and the 30° right-anterior oblique (RAO) projections were calculated for a wide range of kVp (50–120 kVp) and total filtration values (2.5–9.0 mm Al). Results: The results consist of radiation doses normalized to a) entrance skin dose (ESD) and b) dose area product (DAP) so that the dose to the unborn child from any fluoroscopic technique and x-ray device used can be calculated. ESD normalized doses ranged from 0.008 (PA, first trimester) to 2.519 μGy/mGy (RAO, third trimester). DAP normalized doses ranged from 0.051 (PA, first trimester) to 12.852 μGy/Gycm2 (RAO, third trimester). Conclusion: Embryo/fetus doses from fluoroscopically guided pacemaker implantation procedures performed on pregnant patients during all stages of gestation can be estimated using the method developed in this study. This study was supported by the Greek Ministry of Education and Religious Affairs, General Secretariat for Research and Technology, Operational Program ‘Education and Lifelong Learning’, ARISTIA (Research project: CONCERT)

  6. Diagnostic value of the fluoroscopic triggering 3D LAVA technique for primary liver cancer.

    Science.gov (United States)

    Shen, Xiao-Yong; Chai, Chun-Hua; Xiao, Wen-Bo; Wang, Qi-Dong

    2010-04-01

    Primary liver cancer (PLC) is one of the common malignant tumors. Liver acquisition with acceleration volume acquisition (LAVA), which allows simultaneous dynamic enhancement of the hepatic parenchyma and vasculature imaging, is of great help in the diagnosis of PLC. This study aimed to evaluate application of the fluoroscopic triggering 3D LAVA technique in the imaging of PLC and liver vasculature. The clinical data and imaging findings of 38 adults with PLC (22 men and 16 women; average age 52 years), pathologically confirmed by surgical resection or biopsy, were collected and analyzed. All magnetic resonance images were obtained with a 1.5-T system (General Electrics Medical Systems) with an eight-element body array coil and application of the fluoroscopic triggering 3D LAVA technique. Overall image quality was assessed on a 5-point scale by two experienced radiologists. All the nodules and blood vessel were recorded and compared. The diagnostic accuracy and feasibility of LAVA were evaluated. Thirty-eight patients gave high quality images of 72 nodules in the liver for diagnosis. The accuracy of LAVA was 97.2% (70/72), and the coincidence rate between the extent of tumor judged by dynamic enhancement and pathological examination was 87.5% (63/72). Displayed by the maximum intensity projection reconstruction, nearly all cases gave satisfactory images of branches III and IV of the hepatic artery. Furthermore, small early-stage enhancing hepatic lesions and the parallel portal vein were also well displayed. Sequence of LAVA provides good multi-phase dynamic enhancement scanning of hepatic lesions. Combined with conventional scanning technology, LAVA effectively and safely displays focal hepatic lesions and the relationship between tumor and normal tissues, especially blood vessels.

  7. Fluoroscopically-guided transnasal insertion of ileus tube intestinal decompression in patients with inoperable malignant bowel obstruction

    International Nuclear Information System (INIS)

    Fang Shiming; Li Haili; Lin Qing; Mao Aiwu; Wu Shaoqiu; Jiang Haosheng; Cao Yan; Wang Zhenlei

    2011-01-01

    Objective: To assess the technical feasibility and effectiveness of fluoroscopically-guided transnasal insertion of ileus tube for intestinal decompression in the treatment of inoperable malignant bowel obstruction. Methods: A total of 211 patients with inoperable malignant bowel obstruction were enrolled in this study. The median KPS scale was 40 (ranged from 20 to 60). Under fluoroscopic guidance, transnasal insertion of ileus tube by using conventional technique or guidewire-catheter exchange technique was performed in all patients. The technical success rate, the clinical effective rate, the curative rate and adverse reactions as well as complications were documented. The correlation among the obstructive sites, obstruction causes and therapeutic effectiveness was analyzed. The ileus tube used in this study was a four-cavity and double-balloon catheter with a diameter of 16 F/18 f, which is produced by Cliny Company. Results: Transnasal drainage tube was successfully inserted into the proximal jejunum in all 211 patients with malignant bowel obstruction, and the total technical success rate was 100%. The initial technical success rate of the traditional technique and the catheter-guidewire exchange method was 85.5% (65/76) and 100% (135/135) respectively, the difference between the two was significant (P<0.05). After 24 hours, the clinical remission rate in the patients with high-level intestinal obstruction, lower-level intestinal obstruction and colorectal obstruction was 95.8% (46/48), 92.9% (117/126) and 83.8% (31/37), respectively. A follow-up of 4-245 days (mean 138 days) was conducted, and the total clinical cure rate was 27.5% (58/211). The clinical cure rate in small intestine obstruction and colorectal obstruction caused by primary tumor or recurrence was 12.7% (20/157) and 59.5% (22/37), respectively (P<0.05). The adverse reactions and complications included uncomfortable pharynx feeling or pain (99.1%, 199/221), the tube obstruction (23.2%, 49

  8. A digital fluoroscopic imaging system for verification during external beam radiotherapy

    International Nuclear Information System (INIS)

    Takai, Michikatsu

    1990-01-01

    A digital fluoroscopic (DF) imaging system has been constructed to obtain portal images for verification during external beam radiotherapy. The imaging device consists of a fluorescent screen viewed by a highly sensitive video camera through a mirror. The video signal is digitized and processed by an image processor which is linked on-line with a host microcomputer. The image quality of the DF system was compared with that of film for portal images of the Burger phantom and the Alderson anthropomorphic phantom using 10 MV X-rays. Contrast resolution of the DF image integrated for 8.5 sec. was superior to the film resolution, while spatial resolution was slightly inferior. The DF image of the Alderson phantom processed by the adaptive histogram equalization was better in showing anatomical landmarks than the film portal image. The DF image integrated for 1 sec. which is used for movie mode can show patient movement during treatment. (author)

  9. Radiation injury of the skin following diagnostic and interventional fluoroscopic procedures

    International Nuclear Information System (INIS)

    Koenig, T.R.; Wagner, L.K.; Mettler, F.A.

    2001-01-01

    Many radiation injuries to the skin, resulting from diagnostic and interventional fluoroscopic procedures, have been reported in recent years. In some cases skin damage was severe and debilitating. We analyzed 72 reports of skin injuries for progression and location of injury, type and number of procedures, and contributing patient and operator factors. Most cases (46) were related to coronary angiography and percutaneous transluminal coronary angioplasty (PTCA). A smaller number was documented after cardiac radiofrequency catheter ablation (12), transjugular intrahepatic portosystemic shunt (TIPS) placement (7), neuroradiological interventions (3) and other procedures (4). Important factors leading to skin injuries were long exposure times over the same skin area, use of high dose rates, irradiation through thick tissue masses, hypersensitivity to radiation, and positioning of arms or breasts into the radiation entrance beam. Physicians were frequently unaware of the high radiation doses involved and did not recognize the injuries as radiation induced. Based on these findings, recommendations to reduce dose and improve patient care are provided. (author)

  10. Fluoroscopic removal of metallic foreign bodies in the stomach with a magnetic orogastric tube

    International Nuclear Information System (INIS)

    Paulson, E.K.; Jaffe, R.B.

    1989-01-01

    Thirty-six cases of metallic foreign bodies in the stomach were referred for fluoroscopically guided removal by means of a 5-mm diameter magnet coupled to an orogastric tube. The foreign bodies included 29 disk batteries, two nails, two screws, a nut and bolt, an unopened jack knife, and a metallic whistle. The average patient age was 4 years (range, 11 months to 13 years). Removal was successful in 33 of the 36 cases (92%). The three failures were the result of inadvertent passage of the foreign body into the duodenum (two cases) and lack of magnetic attraction (one case). There were no complications. No patient required general anesthesia, hospital admission, or endoscopic surgical intervention

  11. Clinical comparison between 100 mm photofluorography and digital (1024/sup 2/) fluoroscopic image acquisition

    International Nuclear Information System (INIS)

    Hynes, D.M.; Edmonds, E.W.; Rowlands, J.A.; Porter, A.J.; Toth, B.D.

    1986-01-01

    The authors describe current work in progress in which a clinical image can be recorded on both 100-mm film and a 1,024/sup 2/ image store with the same exposure. The 100-mm film is exposed in the usual manner. However, the same radiation exposure is utilized by the optics of the beam splitter to transfer the output image of the intensifier into a 1,024/sup 2/ image store and thence to hard copy by multiformat camera or laser printer. Comparative phantom and clinical images will be presented, along with observations on dose rates needed for diagnostic digital imaging. Use of this system may allow fluoroscopic dose rates to be reduced

  12. Characterization of MOSFET Dosimeter Angular Response Using a Spherical Phantom for Fluoroscopic Dosimetry.

    Science.gov (United States)

    Wang, Chu; Hill, Kevin; Yoshizumi, Terry

    2016-01-01

    Metal-Oxide Semiconductor Field-Effect Transistor (MOSFET) dosimeters, placed in anthropomorphic phantoms, are a standard method for organ dosimetry in medical x-ray imaging applications. However, many x-ray applications, particularly fluoroscopy procedures, use variable projection angles. During dosimetry, the MOSFET detector active area may not always be perpendicular to the x-ray beam. The goal of this study was to characterize the dosimeter's angular response in the fluoroscopic irradiation involved in pediatric cardiac catheterization procedures, during which a considerable amount of fluoroscopic x-ray irradiation is often applied from various projection angles. A biological x-ray irradiator was used to simulate the beam quality of a biplane fluoroscopy imaging system. A custom-designed acrylic spherical scatter phantom was fabricated to measure dosimeter response (in mV) in two rotational axes, axial (ψ) and normal-to-axial (θ), in 30° increments, as well as four common oblique angles used in cardiac catheterization: a) 90° Left Anterior Oblique (LAO); b) 70° LAO/ 20° Cranial; c) 20° LAO/ 15° Cranial; and d) 30° Right Anterior Oblique (RAO). All results were normalized to the angle where the dosimeter epoxy is perpendicular to the beam or the Posterior-Anterior projection angle in the clinical setup. The relative response in the axial rotation was isotropic (within ± 10% deviation); that in the normal-to-axial rotation was isotropic in all angles except the ψ = 270° angle, where the relative response was 83 ± 9%. No significant deviation in detector response was observed in the four common oblique angles, with their relative responses being: a) 102 ± 3%; b) 90 ± 3%; c) 92 ± 3%; and d) 95 ± 3%, respectively. These angular correction factors will be used in future dosimetry studies for fluoroscopy. The spherical phantom may be useful for other applications, as it allows the measurement of dosimeter response in virtually all angles in the 3

  13. Supplementation of bone marrow aspirate-derived platelet-rich plasma for treating radiation-induced ulcer after cardiac fluoroscopic procedures: A preliminary report

    Directory of Open Access Journals (Sweden)

    Soh Nishimoto

    2012-01-01

    Full Text Available Background: The frequency of encountering radiodermatitis caused by X-ray fluoroscopic procedures for ischaemic heart disease is increasing. In severe cases, devastating ulcers with pain, for which conservative therapy is ineffective, emerge. Radiation-induced ulcers are notorious for being difficult to treat. Simple skin grafting often fails because of the poor state of the wound bed. A vascularized flap is a very good option. However, the non-adherence of the well-vascularized flap with the irradiated wound bed is frequently experienced. Aim: To ameliorate the irradiated wound bed, bone marrow-derived platelet-rich plasma (bm-PRP was delivered during the surgery. Materials and Methods: Four patients with severe cutaneous radiation injury accompanied by unbearable pain after multiple fluoroscopic procedures for ischaemic heart disease were treated. Wide excision of the lesion and coverage with a skin flap supplemented with bm-PRP injection was performed. Results: All patients obtained wound closure and were relieved from pain. No complication concerning the bone marrow aspiration and delivery of bm-PRP was observed. Conclusions: Supplementation of bm-PRP can be an option without major complications, time, and cost to improve the surgical outcome for irradiated wounds.

  14. Evaluation of the impact of a system for real-time visualisation of occupational radiation dose rate during fluoroscopically guided procedures

    International Nuclear Information System (INIS)

    Sandblom, V; Almén, A; Cederblad, A.; Båth, M; Lundh, C; Mai, T; Rystedt, H

    2013-01-01

    Optimisation of radiological protection for operators working with fluoroscopically guided procedures has to be performed during the procedure, under varying and difficult conditions. The aim of the present study was to evaluate the impact of a system for real-time visualisation of radiation dose rate on optimisation of occupational radiological protection in fluoroscopically guided procedures. Individual radiation dose measurements, using a system for real-time visualisation, were performed in a cardiology laboratory for three cardiologists and ten assisting nurses. Radiation doses collected when the radiation dose rates were not displayed to the staff were compared to radiation doses collected when the radiation dose rates were displayed. When the radiation dose rates were displayed to the staff, one cardiologist and the assisting nurses (as a group) significantly reduced their personal radiation doses. The median radiation dose (H p (10)) per procedure decreased from 68 to 28 μSv (p = 0.003) for this cardiologist and from 4.3 to 2.5 μSv (p = 0.001) for the assisting nurses. The results of the present study indicate that a system for real-time visualisation of radiation dose rate may have a positive impact on optimisation of occupational radiological protection. In particular, this may affect the behaviour of staff members practising inadequate personal radiological protection. (paper)

  15. Implementation of a competency check-off in diagnostic fluoroscopy for radiology trainees: impact on reducing radiation for three common fluoroscopic exams in children

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Sweta [University of Missouri-Kansas City SOM, Department of Radiology, Kansas City, MO (United States); Desouches, Stephane L. [University of Missouri-Kansas City SOM, Department of Radiology, Kansas City, MO (United States); St. Luke' s Hospital, Department of Radiology, Kansas City, MO (United States); Lowe, Lisa H.; Kasraie, Nima; Reading, Brenton [University of Missouri-Kansas City SOM, Department of Radiology, Kansas City, MO (United States); Children' s Mercy Hospitals and Clinics, Department of Radiology, Kansas City, MO (United States)

    2014-07-24

    Fluoroscopy is an important tool for diagnosis in the pediatric population, but it carries the risk of radiation exposure. Because radiology resident education and experience in the use of fluoroscopy equipment in children vary, we implemented an intervention to standardize fluoroscopy training. The purpose of this study is to determine the impact of implementing a fluoroscopy competency check-off for radiology resident trainees aimed at decreasing radiation exposure in three common pediatric fluoroscopic studies. A fluoroscopy competency check-off form was developed for radiology resident trainees performing pediatric procedures. Techniques used to limit radiation exposure for common pediatric radiologic studies were reviewed as part of the check-off process. Pediatric radiologists supervised each trainee until they demonstrated competence to independently perform three specified procedures. Radiation dose was recorded for the three procedures, upper GI (UGI), voiding cystourethrogram (VCUG) and oropharyngeal (OPM) exams, over 6 months preceding and 6 months following implementation of the competency check-off. The mean cumulative dose for each procedure was compared before and after implementation of competency check-off using a Kruskal-Wallis test. During the 12-month study period doses from 909 fluoroscopic procedures were recorded. In the 6 months preceding competency check-off implementation, procedures were performed by 24 radiology resident trainees including 171 UGI, 176 VCUG and 171 OPM exams. In the 6 months following competency check-off, 23 trainees performed 114 UGI, 145 VCUG and 132 OPM exams. After competency check-off implementation, a statistically significant reduction in average radiation dose was found for all three studies (P < 0.001). Median cumulative doses (mGy) were decreased by 33%, 36% and 13% for UGIs, VCUGs and OPMs, respectively. Implementation of a competency check-off for radiology resident trainees can reduce average radiation

  16. Implementation of a competency check-off in diagnostic fluoroscopy for radiology trainees: impact on reducing radiation for three common fluoroscopic exams in children

    International Nuclear Information System (INIS)

    Shah, Sweta; Desouches, Stephane L.; Lowe, Lisa H.; Kasraie, Nima; Reading, Brenton

    2015-01-01

    Fluoroscopy is an important tool for diagnosis in the pediatric population, but it carries the risk of radiation exposure. Because radiology resident education and experience in the use of fluoroscopy equipment in children vary, we implemented an intervention to standardize fluoroscopy training. The purpose of this study is to determine the impact of implementing a fluoroscopy competency check-off for radiology resident trainees aimed at decreasing radiation exposure in three common pediatric fluoroscopic studies. A fluoroscopy competency check-off form was developed for radiology resident trainees performing pediatric procedures. Techniques used to limit radiation exposure for common pediatric radiologic studies were reviewed as part of the check-off process. Pediatric radiologists supervised each trainee until they demonstrated competence to independently perform three specified procedures. Radiation dose was recorded for the three procedures, upper GI (UGI), voiding cystourethrogram (VCUG) and oropharyngeal (OPM) exams, over 6 months preceding and 6 months following implementation of the competency check-off. The mean cumulative dose for each procedure was compared before and after implementation of competency check-off using a Kruskal-Wallis test. During the 12-month study period doses from 909 fluoroscopic procedures were recorded. In the 6 months preceding competency check-off implementation, procedures were performed by 24 radiology resident trainees including 171 UGI, 176 VCUG and 171 OPM exams. In the 6 months following competency check-off, 23 trainees performed 114 UGI, 145 VCUG and 132 OPM exams. After competency check-off implementation, a statistically significant reduction in average radiation dose was found for all three studies (P < 0.001). Median cumulative doses (mGy) were decreased by 33%, 36% and 13% for UGIs, VCUGs and OPMs, respectively. Implementation of a competency check-off for radiology resident trainees can reduce average radiation

  17. Fluoroscopically-guided transforaminal epidural steroid injection for the treatment of sciatica due to herniated nucleus pulposus

    International Nuclear Information System (INIS)

    Liu Xiao; Wang Jianhui; Duan Zhaohui; Xu Zhitao; Shu Xiaomin; Qiu Ronghua

    2009-01-01

    Objective: To discuss the therapeutic benefit of fluoroscopically-guided lumbar transforaminal epidural steroid injections (TFESI) in treating patients with sciatica due to a herniated nucleus pulposus. Methods: From October 2004 to November 2007, fluoroscopically-guided lumbar TFESI as performed in 79 patients (41 males and 38 females with a mean age of 45.75 years,ranged from 20 to 70 years) with sciatica due to a herniated nucleus pulposus. Patients had a symptomatic course of disease from 8 weeks to 22 years and showed no response to conservative treatment. The diagnosis was confirmed by computed tomography or magnetic resonance imaging. TFESI was performed at patient's request. Additional injections, up to 3 times, were given with an interval of 7 or 10 days. The injection medicine consisted of 25 mg of prednisolone acetate and (9-14) ml of 0.5% lidocaine. Patients were evaluated by an independent observer and received questionnaires before the initial injection and at 6,12 months after TFESI. Questionnaires included an eleven points visual analog scale (VAS) and a five points patient satisfaction scale. A successful outcome required a patient satisfaction scale score of 3 (very good) or 4(excellent) and a reduction on the VAS score of 2 or more points after TFESI. Pain relief was classified as 'excellent' when the pain was completely resolved or diminished by 5 points or more, as 'good' when a diminution of pain was 2 points or more, as 'fair' and 'poor' when a diminution of pain was 1 point or less, or even an increase in pain. Results: Twenty-nine patients received single injection, 22 patients received two, 15 patients received three and 13 patients received four times of injection, with a mean of 1.96 times per patient. The mean VAS scores were 6.5(ranged 3.5-9.5) before and 3.8(ranged 0-9.5) 6 months after the procedure. Pain relief was graded as excellent in 35 patients (44.3%), good in 26 patients(32.9%), fair in 10 patients(12.7%), and poor in 8

  18. Fluoroscopic removal of retrievable self-expandable metal stents in patients with malignant oesophageal strictures: Experience with a non-endoscopic removal system.

    Science.gov (United States)

    Kim, Pyeong Hwa; Song, Ho-Young; Park, Jung-Hoon; Zhou, Wei-Zhong; Na, Han Kyu; Cho, Young Chul; Jun, Eun Jung; Kim, Jun Ki; Kim, Guk Bae

    2017-03-01

    To evaluate clinical outcomes of fluoroscopic removal of retrievable self-expandable metal stents (SEMSs) for malignant oesophageal strictures, to compare clinical outcomes of three different removal techniques, and to identify predictive factors of successful removal by the standard technique (primary technical success). A total of 137 stents were removed from 128 patients with malignant oesophageal strictures. Primary overall technical success and removal-related complications were evaluated. Logistic regression models were constructed to identify predictive factors of primary technical success. Primary technical success rate was 78.8 % (108/137). Complications occurred in six (4.4 %) cases. Stent location in the upper oesophagus (P=0.004), stricture length over 8 cm (P=0.030), and proximal granulation tissue (Pstent location in the upper oesophagus, and stricture length over 8 cm were negative predictive factors for primary technical success by standard extraction and may require a modified removal technique. • Fluoroscopic retrievable SEMS removal is safe and effective. • Standard removal technique by traction is effective in the majority of patients. • Three negative predictive factors of primary technical success were identified. • Caution should be exercised during the removal in those situations. • Eversion technique is effective in cases of proximal granulation tissue.

  19. Fluoroscopically guided caudal epidural steroid injection for management of degenerative lumbar spinal stenosis: short-term and long-term results

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joon Woo; Myung, Jae Sung; Kang, Heung Sik [Seoul National University Bundang Hospital, Department of Radiology, Seong Nam, Gyeongi-do (Korea); Park, Kun Woo; Yeom, Jin S. [Seoul National University Bundang Hospital, Department of Orthopaedic Surgery, Seong Nam, Gyeongi-do (Korea); Kim, Ki-Jeong; Kim, Hyun-Jib [Seoul National University Bundang Hospital, Department of Neurosurgery, Seong Nam, Gyeongi-do (Korea)

    2010-07-15

    To evaluate the short-term and long-term effects of fluoroscopically guided caudal epidural steroid injection (ESI) for the management of degenerative lumbar spinal stenosis (DLSS) and to analyze outcome predictors. All patients who underwent caudal ESI in 2006 for DLSS were included in the study. Response was based on chart documentation (aggravated, no change, slightly improved, much improved, no pain). In June 2009 telephone interviews were conducted, using formatted questions including the North American Spine Society (NASS) patient satisfaction scale. For short-term and long-term effects, age difference was evaluated by the Mann-Whitney U test, and gender, duration of symptoms, level of DLSS, spondylolisthesis, and previous operations were evaluated by Fisher's exact test. Two hundred and sixteen patients (male: female = 75:141; mean age 69.2 years; range 48{proportional_to}91 years) were included in the study. Improvements (slightly improved, much improved, no pain) were seen in 185 patients (85.6%) after an initial caudal ESI and in 189 patients (87.5%) after a series of caudal ESIs. Half of the patients (89/179, 49.8%) replied positively to the NASS patient satisfaction scale (1 or 2). There were no significant outcome predictors for either the short-term or the long-term responses. Fluoroscopically guided caudal ESI was effective for the management of DLSS (especially central canal stenosis) with excellent short-term and good long-term results, without significant outcome predictors. (orig.)

  20. The child fluoroscopic examination in the I.I.-DR. Reduction of radiation exposure dose

    International Nuclear Information System (INIS)

    Endo, Takayuki

    2001-01-01

    This examination for I.I.-DR conditions was done for the purpose of reducing radiation exposure dose in child gastrointestinal fluoroscopy. Fluoroscopic apparatus used was Toshiba MAX-1000A with imaging recorder DDX-1000A. Dose was measured with a thimble ionization chamber Radcal Corporation Model 9015. Examinations for conditions were performed with the standard dose determined, the digital value 300, giving the plateau contrast ratio of acryl plate/barium sulfate. Reduction to about 10% dose (57 μGy/min for pulse fluoroscopy and 6.8 μGy/film for filming) relative to the usual method (764 μGy/min and 36.0 μGy/film, respectively) was found attained with additional filter of Al 0.5 mm + Cu 0.2 mm and IRIS diameter 100 with acryl thickness of 10 cm. Actual images of 6 months old baby were presented. (K.H.)

  1. Discrepancy between fluoroscopic arthrography and magnetic resonance arthrography in patients with arthroscopically confirmed supraspinatus tendon tears: The additional benefit of cine fluoroscopic arthrography images

    International Nuclear Information System (INIS)

    Hahn, Seok; Lee, Young Han; Suh, Jin Suck

    2016-01-01

    To determine the additional diagnostic benefits of fluoroscopic arthrography (FA) in patients with full-thickness supraspinatus tendon (SST) tears by comparing FA images with magnetic resonance arthrography (MRA) images. This study included FA and MRA images of 53 patients who were confirmed to have full-thickness SST tears by arthroscopy. In the FA analysis, the presence of contrast leakage into the subacromial-subdeltoid bursa was recorded. In the MRA analysis, contrast leakage, retraction of a torn tendon, width and length of the tear, and supraspinatus atrophy were evaluated. Patients were divided into the concordant group or the discordant group based on the presence of contrast leakage to compare the characteristics of SST tears. We used Fisher's exact test and two-sample t-test for the comparison. Of the 53 patients, 34 were included in the concordant group and 19 were included in the discordant group. In the concordant group, the grades of retraction were higher than those in the discordant group; the width and length of the tears were larger. Muscle atrophy was more severe in the concordant group. A full-thickness SST tear did not always exhibit contrast leakage on FA, particularly small SST tears or tears with low-grade retraction. FA can provide diagnostic information regarding the severity of full-thickness SST tears by itself

  2. Discrepancy between fluoroscopic arthrography and magnetic resonance arthrography in patients with arthroscopically confirmed supraspinatus tendon tears: The additional benefit of cine fluoroscopic arthrography images

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Seok; Lee, Young Han; Suh, Jin Suck [Dept. Radiology, Research Institute of Radiological Science, Medical Convergence Research Institute, and Severance Biomedical Science Institute, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-12-15

    To determine the additional diagnostic benefits of fluoroscopic arthrography (FA) in patients with full-thickness supraspinatus tendon (SST) tears by comparing FA images with magnetic resonance arthrography (MRA) images. This study included FA and MRA images of 53 patients who were confirmed to have full-thickness SST tears by arthroscopy. In the FA analysis, the presence of contrast leakage into the subacromial-subdeltoid bursa was recorded. In the MRA analysis, contrast leakage, retraction of a torn tendon, width and length of the tear, and supraspinatus atrophy were evaluated. Patients were divided into the concordant group or the discordant group based on the presence of contrast leakage to compare the characteristics of SST tears. We used Fisher's exact test and two-sample t-test for the comparison. Of the 53 patients, 34 were included in the concordant group and 19 were included in the discordant group. In the concordant group, the grades of retraction were higher than those in the discordant group; the width and length of the tears were larger. Muscle atrophy was more severe in the concordant group. A full-thickness SST tear did not always exhibit contrast leakage on FA, particularly small SST tears or tears with low-grade retraction. FA can provide diagnostic information regarding the severity of full-thickness SST tears by itself.

  3. TU-D-209-03: Alignment of the Patient Graphic Model Using Fluoroscopic Images for Skin Dose Mapping

    Energy Technology Data Exchange (ETDEWEB)

    Oines, A; Oines, A; Kilian-Meneghin, J; Karthikeyan, B; Rudin, S; Bednarek, D [University at Buffalo (SUNY) School of Med., Buffalo, NY (United States)

    2016-06-15

    Purpose: The Dose Tracking System (DTS) was developed to provide realtime feedback of skin dose and dose rate during interventional fluoroscopic procedures. A color map on a 3D graphic of the patient represents the cumulative dose distribution on the skin. Automated image correlation algorithms are described which use the fluoroscopic procedure images to align and scale the patient graphic for more accurate dose mapping. Methods: Currently, the DTS employs manual patient graphic selection and alignment. To improve the accuracy of dose mapping and automate the software, various methods are explored to extract information about the beam location and patient morphology from the procedure images. To match patient anatomy with a reference projection image, preprocessing is first used, including edge enhancement, edge detection, and contour detection. Template matching algorithms from OpenCV are then employed to find the location of the beam. Once a match is found, the reference graphic is scaled and rotated to fit the patient, using image registration correlation functions in Matlab. The algorithm runs correlation functions for all points and maps all correlation confidences to a surface map. The highest point of correlation is used for alignment and scaling. The transformation data is saved for later model scaling. Results: Anatomic recognition is used to find matching features between model and image and image registration correlation provides for alignment and scaling at any rotation angle with less than onesecond runtime, and at noise levels in excess of 150% of those found in normal procedures. Conclusion: The algorithm provides the necessary scaling and alignment tools to improve the accuracy of dose distribution mapping on the patient graphic with the DTS. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

  4. TU-D-209-03: Alignment of the Patient Graphic Model Using Fluoroscopic Images for Skin Dose Mapping

    International Nuclear Information System (INIS)

    Oines, A; Oines, A; Kilian-Meneghin, J; Karthikeyan, B; Rudin, S; Bednarek, D

    2016-01-01

    Purpose: The Dose Tracking System (DTS) was developed to provide realtime feedback of skin dose and dose rate during interventional fluoroscopic procedures. A color map on a 3D graphic of the patient represents the cumulative dose distribution on the skin. Automated image correlation algorithms are described which use the fluoroscopic procedure images to align and scale the patient graphic for more accurate dose mapping. Methods: Currently, the DTS employs manual patient graphic selection and alignment. To improve the accuracy of dose mapping and automate the software, various methods are explored to extract information about the beam location and patient morphology from the procedure images. To match patient anatomy with a reference projection image, preprocessing is first used, including edge enhancement, edge detection, and contour detection. Template matching algorithms from OpenCV are then employed to find the location of the beam. Once a match is found, the reference graphic is scaled and rotated to fit the patient, using image registration correlation functions in Matlab. The algorithm runs correlation functions for all points and maps all correlation confidences to a surface map. The highest point of correlation is used for alignment and scaling. The transformation data is saved for later model scaling. Results: Anatomic recognition is used to find matching features between model and image and image registration correlation provides for alignment and scaling at any rotation angle with less than onesecond runtime, and at noise levels in excess of 150% of those found in normal procedures. Conclusion: The algorithm provides the necessary scaling and alignment tools to improve the accuracy of dose distribution mapping on the patient graphic with the DTS. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

  5. Concomitant Intracranial and Lumbar Chronic Subdural Hematoma Treated by Fluoroscopic Guided Lumbar Puncture: A Case Report and Literature Review

    Science.gov (United States)

    ICHINOSE, Daisuke; TOCHIGI, Satoru; TANAKA, Toshihide; SUZUKI, Tomoya; TAKEI, Jun; HATANO, Keisuke; KAJIWARA, Ikki; MARUYAMA, Fumiaki; SAKAMOTO, Hiroki; HASEGAWA, Yuzuru; TANI, Satoshi; MURAYAMA, Yuichi

    2018-01-01

    A 40-year-old man presented with a severe headache, lower back pain, and lower abdominal pain 1 month after a head injury caused by falling. Computed tomography (CT) of the head demonstrated bilateral chronic subdural hematoma (CSDH) with a significant amount in the left frontoparietal region. At the same time, magnetic resonance imaging (MRI) of the lumbar spine also revealed CSDH from L2 to S1 level. A simple drainage for the intracranial CSDH on the left side was performed. Postoperatively, the headache was improved; however, the lower back and abdominal pain persisted. Aspiration of the liquefied spinal subdural hematoma was performed by a lumbar puncture under fluoroscopic guidance. The clinical symptoms were dramatically improved postoperatively. Concomitant intracranial and spinal CSDH is considerably rare so only 23 cases including the present case have been reported in the literature so far. The etiology and therapeutic strategy were discussed with a review of the literature. Therapeutic strategy is not established for these two concomitant lesions. Conservative follow-up was chosen for 14 cases, resulting in a favorable clinical outcome. Although surgical evacuation of lumbosacral CSDH was performed in seven cases, an alteration of cerebrospinal fluid (CSF) pressure following spinal surgery should be reminded because of the intracranial lesion. Since CSDH is well liquefied in both intracranial and spinal lesion, a less invasive approach is recommended not only for an intracranial lesion but also for spinal lesion. Fluoroscopic-guided lumbar puncture for lumbosacral CSDH following burr hole surgery for intracranial CSDH could be a recommended strategy. PMID:29479039

  6. Radiation dose to the operator during fluoroscopically guided spine procedures

    Energy Technology Data Exchange (ETDEWEB)

    Roccatagliata, Luca; Pravata, Emanuele; Cianfoni, Alessandro [Department of Neuroradiology, Neurocenter of Southern Switzerland, Ospedale Regionale di Lugano, Lugano (Switzerland); Presilla, Stefano [Unita di Fisica Medica, Ente Ospedaliero Cantonale (EOC), Bellinzona (Switzerland)

    2017-09-15

    Fluoroscopy is widely used to guide diagnostic and therapeutic spine procedures. The purpose of this study was to quantify radiation incident on the operator (operator Air Kerma) during a wide range of fluoroscopy-guided spine procedures and its correlation with the amount of radiation incident on the patient (Kerma Area Product - KAP). We retrospectively included 57 consecutive fluoroscopically guided spine procedures. KAP [Gy cm{sup 2}] and total fluoroscopy time were recorded for each procedure. An electronic dosimeter recorded the operator Air Kerma [μGy] for each procedure. Operator Air Kerma for each procedure, correlation between KAP and operator Air Kerma, and between KAP and fluoroscopy time was obtained. Operator Air Kerma was widely variable across procedures, with median value of 6.4 μGy per procedure. Median fluoroscopy time and median KAP per procedure were 2.6 min and 4.7 Gy cm{sup 2}, respectively. There was correlation between operator Air Kerma and KAP (r{sup 2} = 0.60), with a slope of 1.6 μGy Air Kerma per unit Gy cm{sup 2} KAP incident on the patient and between fluoroscopy time and KAP (r{sup 2} = 0.63). Operator Air Kerma during individual fluoroscopy-guided spine procedures can be approximated from the commonly and readily available information of the total amount of radiation incident on the patient, measured as KAP. (orig.)

  7. Pediatric patient and staff dose measurements in barium meal fluoroscopic procedures

    Science.gov (United States)

    Filipov, D.; Schelin, H. R.; Denyak, V.; Paschuk, S. A.; Porto, L. E.; Ledesma, J. A.; Nascimento, E. X.; Legnani, A.; Andrade, M. E. A.; Khoury, H. J.

    2015-11-01

    This study investigates patient and staff dose measurements in pediatric barium meal series fluoroscopic procedures. It aims to analyze radiographic techniques, measure the air kerma-area product (PKA), and estimate the staff's eye lens, thyroid and hands equivalent doses. The procedures of 41 patients were studied, and PKA values were calculated using LiF:Mg,Ti thermoluminescent dosimeters (TLDs) positioned at the center of the patient's upper chest. Furthermore, LiF:Mg,Cu,P TLDs were used to estimate the equivalent doses. The results showed a discrepancy in the radiographic techniques when compared to the European Commission recommendations. Half of the results of the analyzed literature presented lower PKA and dose reference level values than the present study. The staff's equivalent doses strongly depends on the distance from the beam. A 55-cm distance can be considered satisfactory. However, a distance decrease of ~20% leads to, at least, two times higher equivalent doses. For eye lenses this dose is significantly greater than the annual limit set by the International Commission on Radiological Protection. In addition, the occupational doses were found to be much higher than in the literature. Changing the used radiographic techniques to the ones recommended by the European Communities, it is expected to achieve lower PKA values ​​and occupational doses.

  8. Patient doses from fluoroscopically guided cardiac procedures in pediatrics

    International Nuclear Information System (INIS)

    Martinez, L C; Vano, E; Gutierrez, F; Rodriguez, C; Gilarranz, R; Manzanas, M J

    2007-01-01

    Infants and children are a higher risk population for radiation cancer induction compared to adults. Although some values on pediatric patient doses for cardiac procedures have been reported, data to determine reference levels are scarce, especially when compared to those available for adults in diagnostic and therapeutic procedures. The aim of this study is to make a new contribution to the scarce published data in pediatric cardiac procedures and help in the determination of future dose reference levels. This paper presents a set of patient dose values, in terms of air kerma area product (KAP) and entrance surface air kerma (ESAK), measured in a pediatric cardiac catheterization laboratory equipped with a biplane x-ray system with dynamic flat panel detectors. Cardiologists were properly trained in radiation protection. The study includes 137 patients aged between 10 days and 16 years who underwent diagnostic catheterizations or therapeutic procedures. Demographic data and technical details of the procedures were also gathered. The x-ray system was submitted to a quality control programme, including the calibration of the transmission ionization chamber. The age distribution of the patients was 47 for 2 respectively for the four age bands. These KAP values increase by a factor of 8 when moving through the four age bands. The probability of a fatal cancer per fluoroscopically guided cardiac procedure is about 0.07%. Median values of ESAK for the four age bands were 46, 50, 56 and 163 mGy, which lie far below the threshold for deterministic effects on the skin. These dose values are lower than those published in previous papers

  9. Self-Expandable Metallic Stent for the Palliative Treatment of Obstructing Left-Sided Colorectal Cancer under Fluoroscopic Guidance: A Comparison of the Clinical Results according to Stent Diameter

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Pyeong Guk; Hong, Hyun Pyo; Choi, Yoon Jung; Lee, Min Hee; Park, Hae Won; Chung, Eun Chul [Kangbuk Samsung Hospital, Seoul (Korea, Republic of); Kim, Sam Soo [Kangwon National University College of Medicine, Chuncheon (Korea, Republic of)

    2010-03-15

    To evaluate the feasibility, effectiveness, and safety of self-expandable metallic stent for the palliative treatment of obstructing left-sided colorectal cancer under fluoroscopic guidance, and to compare results according to the stent diameter. Under fluoroscopic guidance, 31 self-expandable metallic stents were placed into 25 patients for palliative purposes. The rates of technical success, clinical success, complications associated with stent insertion, patient survival, and primary stent patency were evaluated. The results were also compared between two groups: 13 patients using stents with a diameter of 22 mm and 12 patients using stents with a diameter of 26 mm. The technical and clinical success rates were 93.5 and 90.3%, respectively. The complications included severe abdominal pain (6.5%), minor rectal bleeding (9.7%), stent migration (9.7%), and tumor ingrowth or overgrowth (9.7%). No statistical differences in technical were detected between the two groups for the clinical success rate and complication rates. The mean survival time was 5.5 +- 1.4 months. The primary stent patency rates were 91.3% at 5 months, 85.2% at 10 months, and 77.4% at 15 months. The mean period of stent patency was 12.4 +- 2.6 months. The mean period of primary stent patency was 16.4 +- 2.6 months in the 26 mm stent group, and significantly higher than 5.4 +- 1.4 months in the 22 mm stent group (p=0.031). A self-expandable metallic stent under fluoroscopic guidance, for the palliative treatment of obstructing left-sided colorectal cancer, was feasible and effective, and yielded good clinical results. The period of primary stent patency of the 26 mm stent group was longer than the 22 mm stent group, and the complication rate was not significantly different between the two stent groups

  10. Self-Expandable Metallic Stent for the Palliative Treatment of Obstructing Left-Sided Colorectal Cancer under Fluoroscopic Guidance: A Comparison of the Clinical Results according to Stent Diameter

    International Nuclear Information System (INIS)

    Kang, Pyeong Guk; Hong, Hyun Pyo; Choi, Yoon Jung; Lee, Min Hee; Park, Hae Won; Chung, Eun Chul; Kim, Sam Soo

    2010-01-01

    To evaluate the feasibility, effectiveness, and safety of self-expandable metallic stent for the palliative treatment of obstructing left-sided colorectal cancer under fluoroscopic guidance, and to compare results according to the stent diameter. Under fluoroscopic guidance, 31 self-expandable metallic stents were placed into 25 patients for palliative purposes. The rates of technical success, clinical success, complications associated with stent insertion, patient survival, and primary stent patency were evaluated. The results were also compared between two groups: 13 patients using stents with a diameter of 22 mm and 12 patients using stents with a diameter of 26 mm. The technical and clinical success rates were 93.5 and 90.3%, respectively. The complications included severe abdominal pain (6.5%), minor rectal bleeding (9.7%), stent migration (9.7%), and tumor ingrowth or overgrowth (9.7%). No statistical differences in technical were detected between the two groups for the clinical success rate and complication rates. The mean survival time was 5.5 ± 1.4 months. The primary stent patency rates were 91.3% at 5 months, 85.2% at 10 months, and 77.4% at 15 months. The mean period of stent patency was 12.4 ± 2.6 months. The mean period of primary stent patency was 16.4 ± 2.6 months in the 26 mm stent group, and significantly higher than 5.4 ± 1.4 months in the 22 mm stent group (p=0.031). A self-expandable metallic stent under fluoroscopic guidance, for the palliative treatment of obstructing left-sided colorectal cancer, was feasible and effective, and yielded good clinical results. The period of primary stent patency of the 26 mm stent group was longer than the 22 mm stent group, and the complication rate was not significantly different between the two stent groups

  11. Feasibility of differential quantification of 3D temporomandibular kinematics during various oral activities using a cone-beam computed tomography-based 3D fluoroscopic method

    Directory of Open Access Journals (Sweden)

    Chien-Chih Chen

    2013-06-01

    Conclusion: A new CBCT-based 3D fluoroscopic method was proposed and shown to be capable of quantitatively differentiating TMJ movement patterns among complicated functional activities. It also enabled a complete description of the rigid-body mandibular motion and descriptions of as many reference points as needed for future clinical applications. It will be helpful for dental practice and for a better understanding of the functions of the TMJ.

  12. An assessment of methods for monitoring entrance surface dose in fluoroscopically guided interventional procedures

    International Nuclear Information System (INIS)

    Waite, J.C.; Fitzgerald, M.

    2001-01-01

    In the light of a growing awareness of the risks of inducing skin injuries as a consequence of fluoroscopically guided interventional procedures (FGIPs), this paper compares three methods of monitoring entrance surface dose (ESD). It also reports measurements of ESDs made during the period August 1998 to June 1999 on 137 patients undergoing cardiac, neurological and general FGIPs. Although the sample is small, the results reinforce the need for routine assessments to be made of ESDs in FGIPs. At present, the most reliable and accurate form of ESD measurement would seem to be arrays of TLDs. However, transducer based methods, although likely to be less accurate, have considerable advantages in relation to a continuous monitoring programme. It is also suggested that there may be the potential locally for threshold dose area product (DAP) values to be set for specific procedures. These could be used to provide early warning of the potential for skin injuries. (author)

  13. Fluoroscopically guided tunneled trans-caudal epidural catheter technique for opioid-free neonatal epidural analgesia.

    Science.gov (United States)

    Franklin, Andrew D; Hughes, Elisabeth M

    2016-06-01

    Epidural analgesia confers significant perioperative advantages to neonates undergoing surgical procedures but may be very technically challenging to place using a standard interlaminar loss-of-resistance to saline technique given the shallow depth of the epidural space. Thoracic epidural catheters placed via the caudal route may reduce the risk of direct neural injury from needle placement, but often pose higher risks of infection and/or improper positioning if placed without radiographic guidance. We present a detailed method of placing a fluoroscopically guided, tunneled transcaudal epidural catheter, which may reduce both of these risks. The accuracy and precision of this technique often provides adequate analgesia to allow for opioid-free epidural infusions as well as significant reductions in systemic opioids through the perioperative period. Opioid-free analgesia using a regional anesthetic technique allows for earlier extubation and reduced perioperative sedation, which may have a less deleterious neurocognitive effect on the developing brain of the neonate.

  14. A review of two methods used in the USA to assess HE during fluoroscopic-based radiology

    International Nuclear Information System (INIS)

    Craig Yoder, R.; Salasky, Mark R.

    2016-01-01

    Dosemeter results for ∼81 500 people performing fluoroscopic and interventional radiology procedures were examined to identify differences between groups monitored either by using two dosemeters, one placed at the collar above the apron and a second placed under the apron on the torso (EDE1) or by using one single dosemeter placed at the collar above the apron (EDE2). The median annual HE was 0.17 mSv for those monitored using the EDE1 protocol and 0.26 mSv for the group using the EDE2 protocol. The EDE2 method was used most frequently with the EDE1 method preferred for those more highly exposed. Approximately, 22 % of dosemeter results for EDE1 were inconsistent with expected norms based on over and under apron dosemeter relationships. (authors)

  15. Fluoroscopically guided automated gun biopsy of chest lesions: diagnostic accuracy and complications

    International Nuclear Information System (INIS)

    Oh, Hee Sul; Han, Young Min; Choi, Ki Chul and others

    1998-01-01

    To determine the diagnostic accuracy and frequency of complications of fluoroscopyguided transthoracic needle biopsy, using an automated gun biopsy system. We retrospectively reviewed 86 patients who underwent automated gun biopsy between October 1995 and October 1996. An 18-gauge cutting needle was used in all cases. All biopsies were performed under fluoroscopic guidance by one interventional radiologist. Tissue sufficient for histologic diagnosis was obtained in 73 of 86 biopsies(84.9%). Fifty-six lesions were malignent and 30 were benign. Sensitivity and diagnostic accuracy for malignant lesions were 87.5% and 87.5%, respectively while cell type specificity in malignant diagnosis was 91.7%(11/12). Sensitivity and diagnostic accuracy for benign lesions were 80.0% and 73.3%, respectively. Postbioptic pneumothorax occurred in three of 86 biopsies(3.5%), one of which required placement of a chest tube. Automated gun biopsy is a simple, safe method for the diagnosis of focal chest lesions. An automated biopsy device offers high diagnostic accuracy in casis involving malignant and benign lesions of the chest, and is particularly useful for determining malignant cell type and specific diagnosis of benign lesions.=20

  16. Transbronchial lung biopsy without fluoroscopic guide in Tehran Imam Khomeini’s Hospital (1999

    Directory of Open Access Journals (Sweden)

    "Firoozbakhsh S

    2002-08-01

    Full Text Available Background: Transbronchial lung biopsy (TBLB is an attractive alternative to open lung biopsy as an initial diagnostic procedure for patients with diffuse parenchymal disease or localized densities beyond direct endoscopic vision. TBLB can be carried out safely without fluoroscopy in patients with diffuse lung disease. Since in our bronchoscopic department fluoroscopy is not available, we planned to evaluate the blind (without fluoroscopic guide TBLB being performed in our department to determine the success rate in obtaining lung tissue, the sensitivity of the procedure and the risk of complications. Materials and Methods: Sixty-Four TBLB were done in our department during a 6 month period (March-September 1999. Results: Lung tissue wasn’t detected in two (3.1 percent samples. Pathological results were helpful in 46 (71.9 percent cases. No evidence of hemoptysis was found after the procedure. Three (4.68 percent cases of pneumothorax was detected. Only one of them required chest tube (1.51 percent. Conclusion: We concluded that blind TBLB was successful in our department with rates of complications comparable to other approved centers.

  17. Exposition of the operator's eye lens and efficacy of radiation shielding in fluoroscopically guided interventions; Exposition der Augenlinse des Untersuchers und Effizienz der Strahlenschutzmittel bei fluoroskopischen Interventionen

    Energy Technology Data Exchange (ETDEWEB)

    Galster, M.; Adamus, R. [Klinikum Nuernberg-Nord, Nuernberg (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Guhl, C. [Klinikum Nuernberg (Germany). Inst. fuer Medizinische Physik; Uder, M. [Erlangen Univ. (Germany). Radiologisches Inst.

    2013-05-15

    Purpose: Efficacy of radiation protection tools for the eye lens dose of the radiologist in fluoroscopic interventions. Materials and Methods: A patient phantom was exposed using a fluoroscopic system. Dose measurements were made at the eye location of the radiologist using an ionization chamber. The setting followed typical fluoroscopic interventions. The reduction of scattered radiation by the equipment-mounted shielding (undercouch drapes and overcouch top) was evaluated. The ceiling-suspended lead acrylic glass screen was tested in scattered radiation generated by a slab phantom. The protective properties of different lead glass goggles and lead acrylic visors were evaluated by thermoluminescence measurements on a head phantom in the primary beam. Results: The exposition of the lens of about 110 to 550 {mu}Sv during radiologic interventions is only slightly reduced by the undercouch drapes. Applying the top in addition to the drapes reduces the lens dose by a factor of 2 for PA projections. In 25 LAO the dose is reduced by a factor between 1.2 and 5. The highest doses were measured for AP angulations furthermore the efficacy of the equipment-mounted shielding is minimal. The ceiling-suspended lead screen reduced scatter by a factor of about 30. The lead glass goggles and visors reduced the lens dose up to a factor of 8 to 10. Depending on the specific design, the tested models are less effective especially for radiation from lateral with cranial angulation of the beam. Occasionally the visors even caused an increase of dose. Conclusion: The exposition of the eye lens can be kept below the new occupational limit recommended by the ICRP if the radiation shielding equipment is used consistently. (orig.)

  18. Quantification of the gravity-dependent change in the C-arm image center for image compensation in fluoroscopic spinal neuronavigation.

    Science.gov (United States)

    Hariri, S; Abbasi, H R; Chin, S; Steinberg, G; Shahidi, R

    2001-01-01

    In the quest to develop a viable, frameless spinal navigation system, many researchers are utilizing the C-arm fluoroscope. However, there is a significant problem with the C-arm that must be quantified: the gravity-dependent sag effect resulting from the geometry of the C-arm and aggravated by the inequity of weight at each end of the C-arm. This study quantified the C-arm sag effect, giving researchers the protocol and data needed to develop a program that accounts for this distortion. The development of spinal navigation algorithms that account for the C-arm sag effect should produce a more accurate spinal navigation system.

  19. Comparison of conventional full spine radiographs and fluoroscopic scanning method in young patients with idiopathic scoliosis; Vergleich von konventioneller Wirbelsaeulenganzaufnahme und fluoroskopischer Scan-Methode bei jungen Patienten mit idiopathischer Skoliose

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, J.; Kottke, R.; Claussen, C. [Abt. fuer Radiologische Diagnostik, Universitaetsklinikum Tuebingen (Germany); Kluba, T.; Niemeyer, T.; Hahnfeldt, T. [Klinik und Poliklinik fuer Orthopaedie, Universitaetsklinikum Tuebingen (Germany); Vonthein, R. [Inst. fuer Medizinische Biometrie, Universitaetsklinikum Tuebingen (Germany); Kamm, K.F. [Philips Medizin Systeme GmbH, Hamburg (Germany)

    2005-08-01

    Purpose: evaluation of low-dose full spine radiographs using fluoroscopic images for the assessment of the Cobb angle measurement in patients with scoliosis. Material and methods: twenty-one consecutive patients (aged 10-27 years, mean age 14 years) with a conventional full spine examination (film speed class 800) underwent a follow-up exam using digital pulsed fluoroscopy (Multi Diagnost 4, Philips Medical Systems, Eindhoven, The Netherlands). The mean follow-up was 9 months. During a synchronized scan with a C-arm speed of 4 cm/sec fluoroscopic images were stored with a pulsed frequency of 3 images per second. The single images were merged and reconstructed to one image with the software easy spine (Philips medical Systems, Eindhoven, The Netherlands). The corresponding dose-area product values (DAP) of both methods were compared. Three independent observers assessed Cobb angles and image quality for each technique. Results: the mean DAP values for conventional imaging was 94.9 cGy x cm{sup 2} and for fluoroscopy 7.8 cGy x cm{sup 2}, respectively. A significant dose reduction of 91.8% (CI 91% to 95%) was calculated. The average absolute angle difference between the observers was found to be 2.7 for conventional imaging and 2.4 for the fluoroscopic method. Interobserver standard deviation of 2.9 was lower than the 5.3 for conventional images. Image quality was better in the conventional images. Conclusion: using the scanning method, we could achieve a mean reduction of the radiation dose of 92%, while the accuracy of the Cobb angle measurements was comparable for both techniques despite of reduced image quality of digital fluoroscopy. (orig.)

  20. Cancer mortality in women after repeated fluoroscopic examinations of the chest

    International Nuclear Information System (INIS)

    Boice, J.D.; Monson, R.R.; Rosenstein, M.

    1981-01-01

    Among 1,047 women fluoroscopically examined in average of 102 times during pneumothorax therapy for tuberculosis and followed up to 45 years (average . 27 yr), no increase in the total number of cancer deaths occurred when these women were compared to 717 women who received other treatments [relative risk (RR) . 0.8]. However, elevated risks of mortality from stomach cancer (RR . 2.3), rectal cancer (RR . 3.8), breast cancer (RR . 1.2), lung cancer (RR . 1.8), and leukemia (RR . 1.2) were observed, but none was statistically significant and all were based on very small numbers of deaths. These increases were balanced by decreases of genital cancer (RR . 0.2), pancreatic cancer (RR . 0.9), lymphoma (RR . 0.6), and all other cancers (RR . 0.1). Average cumulative absorbed doses were 110 rads for the lungs, 33 rads for the trunk, 13 rads for the active bone marrow, and 7 rads for the stomach. The following upper levels of excess risk could be excluded with 95% confidence: 3.5 deaths/10(6) woman-year (WY)-rad for lung cancer, 4.8 deaths/10(6) WY-rad for lymphoma, and 12 deaths/10(6) WY-rad for leukemia. These findings indicated that the carcinogenic effect of multiple low-dose X-ray exposures was not greater than that currently assumed

  1. Eye lens dosimetry for fluoroscopically guided clinical procedures: practical approaches to protection and dose monitoring

    International Nuclear Information System (INIS)

    Martin, Colin J.

    2016-01-01

    Doses to the eye lenses of clinicians undertaking fluoroscopically guided procedures can exceed the dose annual limit of 20 mSv, so optimisation of radiation protection is essential. Ceiling-suspended shields and disposable radiation absorbing pads can reduce eye dose by factors of 2-7. Lead glasses that shield against exposures from the side can lower doses by 2.5-4.5 times. Training in effective use of protective devices is an essential element in achieving good protection and acceptable eye doses. Effective methods for dose monitoring are required to identify protection issues. Dosemeters worn adjacent to the eye provide the better option for interventional clinicians, but an unprotected dosemeter worn at the neck will give an indication of eye dose that is adequate for most interventional staff. Potential requirements for protective devices and dose monitoring can be determined from risk assessments using generic values for dose linked to examination workload. (author)

  2. Evaluation of the UF/NCI hybrid computational phantoms for use in organ dosimetry of pediatric patients undergoing fluoroscopically guided cardiac procedures

    Science.gov (United States)

    Marshall, Emily L.; Borrego, David; Tran, Trung; Fudge, James C.; Bolch, Wesley E.

    2018-03-01

    Epidemiologic data demonstrate that pediatric patients face a higher relative risk of radiation induced cancers than their adult counterparts at equivalent exposures. Infants and children with congenital heart defects are a critical patient population exposed to ionizing radiation during life-saving procedures. These patients will likely incur numerous procedures throughout their lifespan, each time increasing their cumulative radiation absorbed dose. As continued improvements in long-term prognosis of congenital heart defect patients is achieved, a better understanding of organ radiation dose following treatment becomes increasingly vital. Dosimetry of these patients can be accomplished using Monte Carlo radiation transport simulations, coupled with modern anatomical patient models. The aim of this study was to evaluate the performance of the University of Florida/National Cancer Institute (UF/NCI) pediatric hybrid computational phantom library for organ dose assessment of patients that have undergone fluoroscopically guided cardiac catheterizations. In this study, two types of simulations were modeled. A dose assessment was performed on 29 patient-specific voxel phantoms (taken as representing the patient’s true anatomy), height/weight-matched hybrid library phantoms, and age-matched reference phantoms. Two exposure studies were conducted for each phantom type. First, a parametric study was constructed by the attending pediatric interventional cardiologist at the University of Florida to model the range of parameters seen clinically. Second, four clinical cardiac procedures were simulated based upon internal logfiles captured by a Toshiba Infinix-i Cardiac Bi-Plane fluoroscopic unit. Performance of the phantom library was quantified by computing both the percent difference in individual organ doses, as well as the organ dose root mean square values for overall phantom assessment between the matched phantoms (UF/NCI library or reference) and the patient

  3. Fluoroscopic-guided primary single-step percutaneous gastrostomy. Initial results using the Freka {sup registered} GastroTube; Primaere einzeitige durchleuchtungsgesteuerte perkutane Gastrostomie (PG). Erste Ergebnisse mit dem Freka {sup registered} GastroTube

    Energy Technology Data Exchange (ETDEWEB)

    Hahne, J.D.; Schoennagel, B.P.; Arndt, C.; Bannas, P.; Koops, A.; Adam, G.; Habermann, C.R. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Zentrum fuer Radiologie; Herrmann, J. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Zentrum fuer Radiologie; Universitaetsklinikum Hamburg-Eppendorf (Germany). Abt. Paediatrische Radiologie

    2011-07-15

    Purpose: To determine the practicability and outcome of fluoroscopic-guided primary one-step treatment of percutaneous gastrostomy (PG) with the system Freka {sup registered} Gastro Tube (Fresenius Kabi, Germany). Materials and Methods: In 39 patients (mean age 62.7 {+-} 12.0 years), primary PG was performed based on clinical indication from August 2009 to April 2010. The intervention was performed by an experienced radiologist under aseptic conditions by direct puncture with Freka {sup registered} Gastro Tube under fluoroscopic guidance. The clinical data and outcome as well as any complications originated from the electronic archive of the University Medical Center Hamburg-Eppendorf. Results: The intervention was technically successful in all 39 patients. Within the mean follow-up time of 155.3 {+-} 73.6 days, 29 patients (74.4 %) did not experience complications. 10 patients (25.6 %) had to be revised. Complications manifested after a mean of 135.6 {+-} 61.2 days and mainly corresponded to accidental dislocation (50 %). One patient had to be surgically revised under suspicion of a malpositioned tube and suspected intestinal perforation. Clinically relevant wound infections were not detected. The total costs per patient were 553.17 Euro for our single-step treatment (OPS 5 - 431.x) vs. 963.69 Euro (OPS 5 - 431.x and OPS 8 - 123.0) for the recommended two-step treatment. Conclusion: Fluoroscopic-guided primary single-step treatment with Freka {sup registered} Gastro Tube system is feasible and not associated with an increased complication rate when compared to published literature applying a two-step treatment approach. Material costs as well as human and time resources could be significantly reduced using the single-step treatment. (orig.)

  4. Scattered radiation dose to radiologist's cornea, thyroid and gonads while performing some x-ray fluoroscopic investigations

    International Nuclear Information System (INIS)

    Chougle, Arun

    1993-01-01

    The mankind has been immensely benefited from discovery of X-ray and it has found wide spread application in diagnosis and treatment. Radiation is harmful and can produce somatic and genetic effects in the exposed person. International Commission on Radiation Protection (ICRP) has recommended a system of dose limitation based on principle of ALARA. All the efforts should be made to keep the radiation dose to the radiation worker as low as possible. Fluoroscopy gives maximum dose to the patient and staff and hence we have attempted to quantify the scattered radiation dose to the cornea, thyroid and gonads of the radiologist performing fluoroscopic examinations such as barium meal, barium swallow, barium enema, myelography, histerosalpingography and fracture reduction. Thermoluminescence dosimetry (TLD) method using CaSO 4 :Dy TLD disc was employed for these measurements. Use of lead apron has reduced the dose to radiologist's gonad. (author). 3 refs., 4 tabs

  5. Patient doses from fluoroscopically guided cardiac procedures in pediatrics

    Science.gov (United States)

    Martinez, L. C.; Vano, E.; Gutierrez, F.; Rodriguez, C.; Gilarranz, R.; Manzanas, M. J.

    2007-08-01

    Infants and children are a higher risk population for radiation cancer induction compared to adults. Although some values on pediatric patient doses for cardiac procedures have been reported, data to determine reference levels are scarce, especially when compared to those available for adults in diagnostic and therapeutic procedures. The aim of this study is to make a new contribution to the scarce published data in pediatric cardiac procedures and help in the determination of future dose reference levels. This paper presents a set of patient dose values, in terms of air kerma area product (KAP) and entrance surface air kerma (ESAK), measured in a pediatric cardiac catheterization laboratory equipped with a biplane x-ray system with dynamic flat panel detectors. Cardiologists were properly trained in radiation protection. The study includes 137 patients aged between 10 days and 16 years who underwent diagnostic catheterizations or therapeutic procedures. Demographic data and technical details of the procedures were also gathered. The x-ray system was submitted to a quality control programme, including the calibration of the transmission ionization chamber. The age distribution of the patients was 47 for <1 year; 52 for 1-<5 years; 25 for 5-<10 years and 13 for 10-<16 years. Median values of KAP were 1.9, 2.9, 4.5 and 15.4 Gy cm2 respectively for the four age bands. These KAP values increase by a factor of 8 when moving through the four age bands. The probability of a fatal cancer per fluoroscopically guided cardiac procedure is about 0.07%. Median values of ESAK for the four age bands were 46, 50, 56 and 163 mGy, which lie far below the threshold for deterministic effects on the skin. These dose values are lower than those published in previous papers.

  6. Contrast fluoroscopic evaluation of gastrointestinal transit times with and without the use of falconry hoods in red-tailed hawks (Buteo jamaicensis).

    Science.gov (United States)

    Doss, Grayson A; Williams, Jackie M; Mans, Christoph

    2017-11-01

    OBJECTIVE To evaluate gastrointestinal transit times in red-tailed hawks (Buteo jamaicensis) by use of contrast fluoroscopic imaging and investigate the effect of falconry hooding in these hawks on gastrointestinal transit time. DESIGN Prospective, randomized, blinded, complete crossover study. ANIMALS 9 healthy red-tailed hawks. PROCEDURES Hawks were gavage-fed a 30% weight-by-volume barium suspension (25 mL/kg [11.3 mL/lb]) into the crop. Fluoroscopic images were obtained at multiple time points after barium administration. Time to filling and emptying of various gastrointestinal tract organs and overall transit time were measured. The effect of hooding (hooded vs nonhooded) on these variables was assessed in a randomized complete crossover design. RESULTS In nonhooded birds, overall gastrointestinal transit time ranged from 30 to 180 minutes (mean ± SD, 100 ± 52 min). Time to complete crop emptying ranged from 30 to 180 minutes (83 ± 49 min). Contrast medium was present in the ventriculus in all birds within 5 minutes of administration and in the small intestines within 5 to 15 minutes (median, 5 min). Hooding of red-tailed hawks resulted in a significant delay of complete crop emptying (no hood, 83 ± 49 minutes; hood, 133 ± 48 minutes), but no significant effects of hooding were found on other measured variables. CONCLUSIONS AND CLINICAL RELEVANCE These results indicated that overall gastrointestinal transit times are faster in red-tailed hawks than has been reported for psittacines and that the use of a falconry hood in red-tailed hawks may result in delayed crop emptying. Hooding did not exert significant effects on overall gastrointestinal transit time in this raptorial species.

  7. Proposed Optimal Fluoroscopic Targets for Cooled Radiofrequency Neurotomy of the Sacral Lateral Branches to Improve Clinical Outcomes: An Anatomical Study.

    Science.gov (United States)

    Stout, Alison; Dreyfuss, Paul; Swain, Nathan; Roberts, Shannon; Loh, Eldon; Agur, Anne

    2017-11-23

    Current sacroiliac joint (SIJ) cooled radiofrequency (RF) is based on fluoroscopic anatomy of lateral branches (LBs) in three specimens. Recent studies confirm significant variation in LB positions. To determine if common fluoroscopic needle placements for cooled SIJ RF are adequate to lesion all S1-3 LBs. If not, would different targets improve lesion accuracy? The LBs of 20 cadavers were dissected bilaterally (40 SIJs), and 26 G radiopaque wires were sutured to the LBs. With a 10-mm radius ruler centered at each foramen, standard targets were assessed, as judged by a clockface on the right, for S1 and S2 at 2:30, 4:00, and 5:30 positions and at S3 at 2:30 and 4:00. Mirror image targets were assessed on the left. Assuming an 8-mm lesion diameter, the percentage of LBs that would not be ablated for each level was determined. Imaging through the superior end plate of S1 was compared against segment specific (SS) imaging. Nine point four percent of LBs would not be ablated at S1 vs 0.99% at S2 vs 35% at S3, and 60% of the 40 SIJs would be completely denervated using current targets. SS imaging did not improve results. Alternate target locations could improve the miss rate to 2.8% at S1 and 0% at S3 and would ablate all LBs in 95% of SIJs. Using a conservative 8-mm lesion measurement, contemporary cooled RF needle targets are inadequate to lesion all target LBs. Modifications to current targets are recommended to increase the effectiveness of the procedure. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  8. The Usefulness of Virtual Fluoroscopic Preprocedural Planning During Percutaneous Transhepatic Biliary Drainage

    Energy Technology Data Exchange (ETDEWEB)

    Kinoshita, Mitsuhiro, E-mail: kinoshita.3216@tokushima-u.ac.jp [Tokushima University Hospital, Department of Radiology (Diagnostic Radiology) (Japan); Shirono, Ryozo; Takechi, Katsuya [Tokushima Red Cross Hospital, Department of Radiology (Japan); Yonekura, Hironobu [Tokushima Red Cross Hospital, Department of Radiological Technology (Japan); Iwamoto, Seiji [Tokushima University Graduate School, Department of Radiology and Radiation Oncology, Institute of Biomedical Sciences (Japan); Shinya, Takayoshi [Tokushima University Hospital, Department of Radiology (Diagnostic Radiology) (Japan); Takao, Shoichiro [Tokushima University Graduate School of Health Science, Department of Diagnostic Radiology (Japan); Harada, Masafumi [Tokushima University Graduate School, Department of Radiology and Radiation Oncology, Institute of Biomedical Sciences (Japan)

    2017-06-15

    Purpose To retrospectively evaluate the usefulness of virtual fluoroscopic preprocedural planning (VFPP) in the percutaneous transhepatic biliary drainage (PTBD) procedure.Materials and MethodsTwenty-two patients who were treated by PTBD were included in this study. Twelve patients were treated using PTBD intraoperative referencing coronal computed tomography (CT) images (i.e., coronal CT group), and ten patients were treated using PTBD intraoperative referencing VFPP images (i.e., VFPP group). To analyze the effect of the intraoperative referencing VFPP image, the VFPP group was retrospectively compared with the coronal CT group.ResultsThe characteristics of both patient groups were not statistically significantly different. There were no significant differences in the targeted bile duct, diameter and depth of the target bile, breath-holding ability, number of targeted bile duct puncture attempts, change in the targeted bile duct, and exchange of the drainage catheter. However, the X-ray fluoroscopy time and the procedure time were significantly shorter in the VFPP group than in the coronal CT group (196 vs. 334 s, P < 0.05; and 16.0 vs. 27.2 min, P < 0.05).ConclusionIntraoperative referencing using the VFPP imaging in PTBD intuitively can be a useful tool for better localization of the guidewire in the bile duct and thereby shorten the X-ray fluoroscopy time and procedure time while minimizing radiation exposure and complications.

  9. Effects of intra-operative fluoroscopic 3D-imaging on peri-operative imaging strategy in calcaneal fracture surgery.

    Science.gov (United States)

    Beerekamp, M S H; Backes, M; Schep, N W L; Ubbink, D T; Luitse, J S; Schepers, T; Goslings, J C

    2017-12-01

    Previous studies demonstrated that intra-operative fluoroscopic 3D-imaging (3D-imaging) in calcaneal fracture surgery is promising to prevent revision surgery and save costs. However, these studies limited their focus to corrections performed after 3D-imaging, thereby neglecting corrections after intra-operative fluoroscopic 2D-imaging (2D-imaging). The aim of this study was to assess the effects of additional 3D-imaging on intra-operative corrections, peri-operative imaging used, and patient-relevant outcomes compared to 2D-imaging alone. In this before-after study, data of adult patients who underwent open reduction and internal fixation (ORIF) of a calcaneal fracture between 2000 and 2014 in our level-I Trauma center were collected. 3D-imaging (BV Pulsera with 3D-RX, Philips Healthcare, Best, The Netherlands) was available as of 2007 at the surgeons' discretion. Patient and fracture characteristics, peri-operative imaging, intra-operative corrections and patient-relevant outcomes were collected from the hospital databases. Patients in whom additional 3D-imaging was applied were compared to those undergoing 2D-imaging alone. A total of 231 patients were included of whom 107 (46%) were operated with the use of 3D-imaging. No significant differences were found in baseline characteristics. The median duration of surgery was significantly longer when using 3D-imaging (2:08 vs. 1:54 h; p = 0.002). Corrections after additional 3D-imaging were performed in 53% of the patients. However, significantly fewer corrections were made after 2D-imaging when 3D-imaging was available (Risk difference (RD) -15%; 95% Confidence interval (CI) -29 to -2). Peri-operative imaging, besides intra-operative 3D-imaging, and patient-relevant outcomes were similar between groups. Intra-operative 3D-imaging provides additional information resulting in additional corrections. Moreover, 3D-imaging probably changed the surgeons' attitude to rely more on 3D-imaging, hence a 15%-decrease of

  10. Contrast media for fluoroscopic examinations of the GI and GU tracts: current challenges and recommendations.

    Science.gov (United States)

    Federle, Michael P; Jaffe, Tracy A; Davis, Peter L; Al-Hawary, Mahmoud M; Levine, Marc S

    2017-01-01

    One of the significant challenges facing radiologists who perform and interpret studies of the gastrointestinal and genitourinary systems have been periodic interruptions in the availability of barium and iodinated contrast media specially formulated for gastrointestinal (GI) and genitourinary (GU) studies. These interruptions are due to the US Food and Drug Administration's recent requirement for more stringent documentation of the safety and efficacy of contrast media and the consolidation among contrast manufacturers. Therefore, radiologists may be required to recommend an alternative means of evaluation, such as computed tomography, magnetic resonance, or endoscopy, or they may need to substitute a different formulation of a contrast agent not specifically developed for GI or GU use, for example the utilization of an agent designed and marketed for vascular use. This article reviews the current status of fluoroscopic contrast media, and provides suggestions and recommendations for the optimal and alternative use of contrast media formulations.

  11. Relationship between source-surface distance and patient dose in fluoroscopic X-ray examinations

    International Nuclear Information System (INIS)

    Suzuki, Shoichi; Asada, Yasuki; Nishi, Kazuta; Mizuno, Emiko; Hara, Natsue; Orito, Takeo; Kamei, Tetsuya; Koga, Sukehiko

    2000-01-01

    The International Electrotechnical Commission, IEC provided in its standard IEC 60601-1-3 (1994) to prevent the use during radioscopic irradiation of focal spot to skin distances less than 20 cm if the X-RAY EQUIPMENT is specified for RADIOSCOPY during surgery or 30 cm for other specified applications. This standard was reflected in the Japanese Industrial Standard JIS Z 4701-1997, which provided the minimum distance from focal spot to skin to be 30 cm for the use of a fluoroscopic and radiographic table (Under-table type). However, JIS had formerly provided the minimum distance to be 40 cm and so does the current Medical Treatment Law. The draft revision for the Medical Treatment Law currently discussed has consideration to adopt the value 30 cm in accordance with the current JIS. Our research intended to investigate the impact on the entrance surface dose for the change of the focal spot to skin distance from 40 cm to 30 cm. The result was 20-30% increase of the entrance surface dose for the focal spot to skin distance 30 cm. Taking patient exposure dose into account, we need further and more sufficient discussion with this result before adopting this value to the Medical Treatment Law. (author)

  12. Fluoroscopic position of the second-generation cryoballoon during ablation in the right superior pulmonary vein as a predictor of phrenic nerve injury.

    Science.gov (United States)

    Saitoh, Yukio; Ströker, Erwin; Irfan, Ghazala; Mugnai, Giacomo; Ciconte, Giuseppe; Hünük, Burak; Velagić, Vedran; Overeinder, Ingrid; Tanaka, Kaoru; Brugada, Pedro; de Asmundis, Carlo; Chierchia, Gian-Battista

    2016-08-01

    Phrenic nerve injury (PNI) is the most frequently observed complication during pulmonary vein isolation procedure using the second-generation cryoballoon (CB). Our objective was to analyse the correlation between the fluoroscopic position of the 28 mm CB during ablation in the right superior pulmonary vein (RSPV) and the occurrence of PNI. A total of 165 patients having undergone the large 28 mm CB ablation were retrospectively reviewed. Positioning of the CB relative to the cardiac silhouette was classified under fluoroscopic guidance in antero-posterior projection during RSPV ablation. Regarding the lower half of the balloon, CB positioning was defined as follows: (A) completely inside the cardiac shadow; (B1) Phrenic nerve injury occurred in 9.7% (16/165) during ablation in the RSPV. The occurrence of PNI was 0.9, 10.6, and 90.1% in positions A, B1, and B2, respectively (A vs. B1, P = 0.01; B1 vs. B2, P < 0.0001). Among other pre-procedural and procedural variables, the B2 position was the strongest independent determinant for predicting PNI at RSPV (P = 0.001, odds ratio: 119.9; 95% confidence interval: 11.6-1234.7) after multivariable analysis. The incidence of PNI at the RSPV significantly increased in case of more distal positioning of the CB relative to the cardiac shadow. This simple and straightforward intra-procedural indicator might prone the operators to attempt occluding the RPSV more proximally in order to avoid PNI. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  13. Radiation dose and intra-articular access: comparison of the lateral mortise and anterior midline approaches to fluoroscopically guided tibiotalar joint injections

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Ambrose J.; Torriani, Martin; Bredella, Miriam A.; Chang, Connie Y.; Simeone, Frank J.; Palmer, William E. [Massachusetts General Hospital, Department of Radiology, Division of Musculoskeletal Imaging and Intervention, Boston, MA (United States); Balza, Rene [Centro Medico de Occidente, Department of Radiology, Maracaibo (Venezuela, Bolivarian Republic of)

    2016-03-15

    To compare the lateral mortise and anterior midline approaches to fluoroscopically guided tibiotalar joint injections with respect to successful intra-articular needle placement, fluoroscopy time, radiation dose, and dose area product (DAP). This retrospective study was IRB-approved and HIPAA-compliant. 498 fluoroscopically guided tibiotalar joint injections were performed or supervised by one of nine staff radiologists from 11/1/2010-12/31/2013. The injection approach was determined by operator preference. Images were reviewed on a PACS workstation to determine the injection approach (lateral mortise versus anterior midline) and to confirm intra-articular needle placement. Fluoroscopy time (minutes), radiation dose (mGy), and DAP (μGy-m{sup 2}) were recorded and compared using the student's t-test (fluoroscopy time) or the Wilcoxon rank sum test (radiation dose and DAP). There were 246 lateral mortise injections and 252 anterior midline injections. Two lateral mortise injections were excluded from further analysis because no contrast was administered. Intra-articular location of the needle tip was documented in 242/244 lateral mortise injections and 252/252 anterior midline injections. Mean fluoroscopy time was shorter for the lateral mortise group than the anterior midline group (0.7 ± 0.5 min versus 1.2 ± 0.8 min, P < 0.0001). Mean radiation dose and DAP were less for the lateral mortise group than the anterior midline group (2.1 ± 3.7 mGy versus 2.5 ± 3.5 mGy, P = 0.04; 11.5 ± 15.3 μGy-m{sup 2} versus 13.5 ± 17.3 μGy-m{sup 2}, P = 0.006). Both injection approaches resulted in nearly 100 % rates of intra-articular needle placement, but the lateral mortise approach used approximately 40 % less fluoroscopy time and delivered 15 % lower radiation dose and DAP to the patient. (orig.)

  14. Visualization of microvessels with in-house micro-angiography

    International Nuclear Information System (INIS)

    Chiku, Masaaki; Nishigami, Kazuhiro; Takeshita, Satoshi

    2005-01-01

    Although therapeutic angiogenesis improved critical limb ischemia in humans, microvessels promoted by therapeutic angiogenesis needed further improvement to be visualized well by conventional angiographic system, because of its limited spatial resolution of 200 μm. We have developed an in-house micro-angiographic system consisting of a high-voltage power X-ray source and a detecting system with high levels of spatial resolution and sensitivity. The in-house microvessel angiographic system demonstrated its ability to evaluate the function of microvessels in vivo, as well as to visualize them with higher precision than the conventional angiographic system. The findings of our study suggest that a novel micro-angiographic system may be useful in evaluating the efficacy of therapeutic angiogenesis in clinical settings. (author)

  15. Patient and staff doses and relationships between them in fluoroscopically guided procedures

    International Nuclear Information System (INIS)

    Avramova-Cholakova, S.; Christova-Popova, Y.; Sagorska, A.

    2015-01-01

    Full text: Medical exposure has the main contribution to man-made sources of exposures to the population in developed countries. Fluoroscopically guided procedures in interventional cardiology, gastroenterology, urology, orthopaedics and others may be related to high doses to both patients and staff. The main risk for both groups is the radiation carcinogenesis and it is increasing with dose. However deterministic effects are also possible: severe patient skin injuries occur sometimes. There are such cases in Bulgarian radiological practice. For the medical staff, involved in the procedures, radiation induced cataract is observed occasionally. Learning objective: In many cases there is direct correlation between patient and staff doses. Several simple rules must be observed in order to decrease exposure. Rules related to patient: Patient dose (dose-area product (DAP), fluoroscopy time, number of series,number of images) should be recorded for every patient; The patient should be positioned as far away as possible from the x-ray tube and as closer as possible to the image intensifier/digital image receptor; Fluoroscopy time should be minimized; Pulsed fluoroscopy with the lowest dose rate and the lowest frame rate providing acceptable image quality should be used; Different skin areas should be exposed in different projections; Oblique projections increase the dose - they should be avoided; Magnification also increases the dose several times and should be avoided; The acquisition mode should be avoided; it delivers dozens of times higher doses. Minimal number of frames and cine runs should be used. Use of “last image hold” is encouraged; The x-ray beam should be collimated to the area of interest. Rules related to staff: The staff receives scattered radiation from patient’s body. Every measure to decrease patient’s dose decreases staff dose as well; Every available protective device should be used (lead apron, thyroid collar, lead glasses, screens). They

  16. Palliation of malignant gastric obstruction : fluoroscopic guided covered metallic stent placement

    International Nuclear Information System (INIS)

    Lee, Jeong Min; Han, Young Min; Kim, Chong Soo; Lee, Sang Yong; Choi, Ki Chul; Lee, Soo Tak; Han, Hyun Young

    2000-01-01

    To demonstrate the feasibility and clinical efficacy of self-expanding, covered metallic stent placement for the palliative treatment of malignant gastric obstruction. Under fluoroscopic guidance, the placement of self-expanding, covered stents was attempted in 23 patients (age range, 31-78 years) with inoperable or recurrent gastric malignancies. All 23 suffered dysphagia and/or vomiting after the ingestion of soft foods, or swallowing difficulty. Three different types of self-expanding, covered metallic stents were used and in all patients, these were placed perorally using over the guide wire technique. Success was defined both technically and clinically. Stent placement was technically successful in 19 patients (82.6%) but because the guidewire failed to successfully negotiate the sites at which there was obstruction, was unsuccessful in four (17.4%). Stent placement was well tolerated in all patients except one, in whom an acutely angled efferent loop from remnant stomach was present. In this case, stent placement required a strong metallic guidewire. After placement, 17 of the 19 patients (89.5%) were able to ingest solid and/or soft foods without dysphagia and showed a markedly decreased incidence of vomiting. Two others showed some improvement in the frequency of vomiting but were able to ingest only a liquid diet. In one patient, the stent migrated two days after the procedure. During the follow-up period of 2-7 months (mean, 74 days), there were no clinically significant complications. For the short-term palliative treatment of patients with gastric inlet or outlet obstruction, the placement of self-expanding metallic stents has proven relatively easy and safe, as well as reasonably effective. (author)

  17. Patient radiation dose audits for fluoroscopically guided interventional procedures

    International Nuclear Information System (INIS)

    Balter, Stephen; Rosenstein, Marvin; Miller, Donald L.; Schueler, Beth; Spelic, David

    2011-01-01

    Purpose: Quality management for any use of medical x-ray imaging should include monitoring of radiation dose. Fluoroscopically guided interventional (FGI) procedures are inherently clinically variable and have the potential for inducing deterministic injuries in patients. The use of a conventional diagnostic reference level is not appropriate for FGI procedures. A similar but more detailed quality process for management of radiation dose in FGI procedures is described. Methods: A method that takes into account both the inherent variability of FGI procedures and the risk of deterministic injuries from these procedures is suggested. The substantial radiation dose level (SRDL) is an absolute action level (with regard to patient follow-up) below which skin injury is highly unlikely and above which skin injury is possible. The quality process for FGI procedures collects data from all instances of a given procedure from a number of facilities into an advisory data set (ADS). An individual facility collects a facility data set (FDS) comprised of all instances of the same procedure at that facility. The individual FDS is then compared to the multifacility ADS with regard to the overall shape of the dose distributions and the percent of instances in both the ADS and the FDS that exceed the SRDL. Results: Samples of an ADS and FDS for percutaneous coronary intervention, using the dose metric of reference air kerma (K a,r ) (i.e., the cumulative air kerma at the reference point), are used to illustrate the proposed quality process for FGI procedures. Investigation is warranted whenever the FDS is noticeably different from the ADS for the specific FGI procedure and particularly in two circumstances: (1) When the facility's local median K a,r exceeds the 75th percentile of the ADS and (2) when the percent of instances where K a,r exceeds the facility-selected SRDL is greater for the FDS than for the ADS. Conclusions: Analysis of the two data sets (ADS and FDS) and of the

  18. Fluoroscopically Guided Transcervical Fallopian Tube Recanalization of Post-Sterilization Reversal Mid-Tubal Obstructions

    International Nuclear Information System (INIS)

    Houston, J. Graeme; Anderson, David; Mills, John; Harrold, Anthony

    2000-01-01

    Purpose: To assess the technical success and early outcome of fluoroscopically guided transcervical fallopian tube recanalization (FTR) in mid-tubal occlusion following sterilization reversal surgery.Methods: From July 1995 to January 1998, patients with greater than 12 months secondary infertility underwent hysterosalpingography (HSG). FTR was performed in proximal or mid-tubal occlusion. Cases of FTR in mid-tubal occlusion were included in this study. Technical success (defined as complete tubal patency) using a standard guidewire and hydrophilic glidewire, the number of patients with at least one patent tube, and the intrauterine and ectopic pregnancy rates were determined.Results: Twenty-six infertile patients with previous sterilization reversal underwent HSG. Eight of 26 (31%) patients (mean age 32 years, range 23-37 years), had attempted FTR for mid-tubal occlusion at the site of surgical anastomosis. Fourteen tubes were attempted as there were two previous salpingectomies. Technical success was achieved in eight of 14 (57%) tubes attempted, resulting in five of eight (62%) patients having at least one patent tube. At follow-up (mean 18 months, range 12-28 months) in these five patients there was one intrauterine pregnancy. There were no ectopic pregnancies.Conclusions: FTR in mid-tubal obstruction in infertile patients following sterilization reversal surgery is technically feasible and may result in intrauterine pregnancy. In this small group there was a lower technical success rate and lower pregnancy rate than in unselected proximal tubal occlusion

  19. Fluoroscopic and CT enteroclysis in children: initial experience, technical feasibility, and utility

    International Nuclear Information System (INIS)

    Brown, Shanaree; Applegate, Kimberly E.; Sandrasegaran, Kumar; Jennings, S.G.; Garrett, Joshua; Maglinte, Dean T.; Skantharajah, Arunan

    2008-01-01

    Partial small-bowel obstruction can be difficult to diagnose on clinical examination. These obstructions might not be detected on routine abdominal/pelvic CT. To evaluate the feasibility, safety, and techniques of fluoroscopic enteroclysis (FE) and CT enteroclysis (CTE), and to review their indications and findings in children. We retrospectively reviewed all enteroclysis studies in children younger than 18 years performed between January 2002 and March 2007. We correlated the results with other abdominal imaging and surgical and pathological findings. The review revealed 112 FE and 74 CTE studies performed in 175 children (mean age 14 years, range 3-18 years). FE and CTE studies were performed most commonly for evaluation of known Crohn disease (FE 38%, CTE 29%) and abdominal pain (FE 26%, CTE 26%). One FE study was terminated because of patient anxiety, and one CTE study was terminated because of patient discomfort. No complications of FE or CTE were reported. The findings were normal in 54% of the FE studies and 46% of the CTE studies. The most common small bowel diagnoses were Crohn disease (FE 34%, CTE 28%) and partial small bowel obstruction (FE 3%, CTE 10%). Two FE studies (2%) and 14 CTE studies (19%) showed abnormalities outside the small bowel. In 54 patients with inflammatory bowel disease, 11 FE studies and 25 CTE studies showed additional bowel abnormalities. Overall, 14 and 21 patients had surgery as a result of the findings of FE and CTE, respectively. FE and CTE are safe, feasible, and accurate in depicting small-bowel pathology in children. These techniques can be particularly useful in children with Crohn disease involving the small bowel. (orig.)

  20. Peripheral Insertion of a Central Venous Access Device Under Fluoroscopic Guidance Using a Peripherally Accessed System (PAS) Port in the Forearm

    International Nuclear Information System (INIS)

    Hata, Yasuhiro; Morita, Sojiro; Morita, Yoshitaka; Awatani, Toshihide; Takasaki, Motohiro; Horimi, Tadashi; Ozawa, Zen

    1998-01-01

    Purpose: We describe the technique, efficacy, and complications of fluoroscopy-guided implantation of a central venous access device using a peripherally accessed system (PAS) port via the forearm. Methods: Beginning in July 1994, 105 central venous access devices were implanted in 104 patients for the long-term infusion of antibiotics or antineoplasmic agents, blood products, or parenteral nutrition. The devices was inserted under fluoroscopic guidance with real-time venography from a peripheral route. Results: All ports were successfully implanted. There were no procedure-related complications. No thrombosis or local infection was observed; however, in six patients catheter-related phlebitis occurred. Conclusion: Fluoroscopy-guided implantation of a central venous access device using a PAS port via the forearm is safe and efficacious, and injection of contrast medium through a peripheral IV catheter before introduction of the catheter helps to avoid catheter-related phlebitis

  1. Upper ankle joint space detection on low contrast intraoperative fluoroscopic C-arm projections

    Science.gov (United States)

    Thomas, Sarina; Schnetzke, Marc; Brehler, Michael; Swartman, Benedict; Vetter, Sven; Franke, Jochen; Grützner, Paul A.; Meinzer, Hans-Peter; Nolden, Marco

    2017-03-01

    Intraoperative mobile C-arm fluoroscopy is widely used for interventional verification in trauma surgery, high flexibility combined with low cost being the main advantages of the method. However, the lack of global device-to- patient orientation is challenging, when comparing the acquired data to other intrapatient datasets. In upper ankle joint fracture reduction accompanied with an unstable syndesmosis, a comparison to the unfractured contralateral site is helpful for verification of the reduction result. To reduce dose and operation time, our approach aims at the comparison of single projections of the unfractured ankle with volumetric images of the reduced fracture. For precise assessment, a pre-alignment of both datasets is a crucial step. We propose a contour extraction pipeline to estimate the joint space location for a prealignment of fluoroscopic C-arm projections containing the upper ankle joint. A quadtree-based hierarchical variance comparison extracts potential feature points and a Hough transform is applied to identify bone shaft lines together with the tibiotalar joint space. By using this information we can define the coarse orientation of the projections independent from the ankle pose during acquisition in order to align those images to the volume of the fractured ankle. The proposed method was evaluated on thirteen cadaveric datasets consisting of 100 projections each with manually adjusted image planes by three trauma surgeons. The results show that the method can be used to detect the joint space orientation. The correlation between angle deviation and anatomical projection direction gives valuable input on the acquisition direction for future clinical experiments.

  2. Real-time fluoroscopic needle guidance in the interventional radiology suite using navigational software for percutaneous bone biopsies in children

    Energy Technology Data Exchange (ETDEWEB)

    Shellikeri, Sphoorti; Srinivasan, Abhay; Krishnamurthy, Ganesh; Vatsky, Seth; Zhu, Xiaowei; Keller, Marc S.; Cahill, Anne Marie [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Setser, Randolph M. [Siemens Medical Solutions USA, Inc., Hoffman Estates, IL (United States); Hwang, Tiffany J. [University of Southern California, Keck School of Medicine, Los Angeles, CA (United States); Girard, Erin [Siemens Medical Solutions USA, Inc., Princeton, NJ (United States)

    2017-07-15

    Navigational software provides real-time fluoroscopic needle guidance for percutaneous procedures in the Interventional Radiology (IR) suite. We describe our experience with navigational software for pediatric percutaneous bone biopsies in the IR suite and compare technical success, diagnostic accuracy, radiation dose and procedure time with that of CT-guided biopsies. Pediatric bone biopsies performed using navigational software (Syngo iGuide, Siemens Healthcare) from 2011 to 2016 were prospectively included and anatomically matched CT-guided bone biopsies from 2008 to 2016 were retrospectively reviewed with institutional review board approval. C-arm CT protocols used for navigational software-assisted cases included institution-developed low-dose (0.1/0.17 μGy/projection), regular-dose (0.36 μGy/projection), or a combination of low-dose/regular-dose protocols. Estimated effective radiation dose and procedure times were compared between software-assisted and CT-guided biopsies. Twenty-six patients (15 male; mean age: 10 years) underwent software-assisted biopsies (15 pelvic, 7 lumbar and 4 lower extremity) and 33 patients (13 male; mean age: 9 years) underwent CT-guided biopsies (22 pelvic, 7 lumbar and 4 lower extremity). Both modality biopsies resulted in a 100% technical success rate. Twenty-five of 26 (96%) software-assisted and 29/33 (88%) CT-guided biopsies were diagnostic. Overall, the effective radiation dose was significantly lower in software-assisted than CT-guided cases (3.0±3.4 vs. 6.6±7.7 mSv, P=0.02). The effective dose difference was most dramatic in software-assisted cases using low-dose C-arm CT (1.2±1.8 vs. 6.6±7.7 mSv, P=0.001) or combined low-dose/regular-dose C-arm CT (1.9±2.4 vs. 6.6±7.7 mSv, P=0.04), whereas effective dose was comparable in software-assisted cases using regular-dose C-arm CT (6.0±3.5 vs. 6.6±7.7 mSv, P=0.7). Mean procedure time was significantly lower for software-assisted cases (91±54 vs. 141±68 min, P=0

  3. Estimation of entrance dose during selected fluoroscopic examinations in some hospitals in Khartoum state

    International Nuclear Information System (INIS)

    Mohammed, Heba Abdalkareem Osman

    2016-01-01

    A diagnostic fluoroscopy is a modality that involves visualizing the anatomy using radiation in real time. Therefore, patients doses have a potential for being great, increasing the chance of the radiation induced carcinogenesis. The objective of this study was to determine the mean entrance surface dose (ESD) from selected fluoroscopic examinations namely, hysterosalpingography (HSG) and ascendingurethogram (ASU) in three hospitals in Khartoum State. A total of 87 and 110 patents for HSG and ASU respectively were examined. The data were collected over four months. The mean ESD for patients who underwent HSG were 16.2 mGy, 20.6 mGy and 25.9 mGY respectively, while the ESD for patient who underwent ascendingurethrogram for AP view were 3.5mGy, 2.9mGy and 11.9mGy and for OB view 15.9 mGy, 18.3 mGy and 25.4 mGy. Patient doses were calculated using mathematical equation and the results were compared with the ESDs calculated using mathematical equation and the results were found to be comparable with the ESDs reported in previous studies and within the guidance level established by the ICRP. Fluoroscopy time, operator skills, x-ray machine type and clinical complexity of the procedures were shown to be major contributors to the variations reported in the measured ESDs. The study demonstrated the need for standardization of techniques throughout the hospitals and suggested that there ia a need to optimize the procedures.(Author)

  4. Fluoroscopically-Guided Posterior Approach for Shoulder Magnetic Resonance Arthrography: Comparison with Conventional Anterior Approach

    International Nuclear Information System (INIS)

    Yoo, Koun J.; Ha, Doo Hoe; Lee, Sang Min

    2011-01-01

    To prospectively evaluate the usefulness of the fluoroscopically-guided posterior approach compared with the anterior approach for shoulder magnetic resonance(MR) arthrography. Institutional review board approval and informed consent were obtained. Among 60 shoulder MR arthrographies performed on 59 patients with symptomatic shoulders, an intra-articular injection was performed (30 cases using the anterior approach and 30 using the posterior approach). Procedure-related pain was assessed by using a 5 score visual analogue scale (VAS). Depth of the puncture and standardized depth of puncture by body mass index (BMI) were recorded. The contrast leakage along the course of the puncture was evaluated by reviewing the MR. The statistical analyses included the Mann-Whitney U and Kruskal-Wallis test. There was no significant difference in VAS scores between the anterior and posterior groups (1.77 ± 1.10 vs. 1.80 ± 0.96). Depth of puncture and standardized depth of puncture by BMI were significantly shorter in the posterior group than those in the anterior group (4.4 ± 0.8 cm and 1.8 ± 0.3 cm vs. 6.6 ± 0.9 cm and 2.8 ± 0.4 cm, p < 0.001), respectively. The incidence of contrast leakage was more frequent in the posterior group (p = 0.003). The posterior approach will be useful in shoulder MR arthrography with a suspected anterior pathology, a postoperative follow-up study or obese patient.

  5. Is lead shielding of patients necessary during fluoroscopic procedures? A study based on kyphoplasty

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Joshua R.; Marsh, Rebecca M.; Silosky, Michael S. [University of Colorado School of Medicine, Department of Radiology, Aurora, CO (United States)

    2018-01-15

    To determine the benefits, risks, and limitations associated with wrapping a patient with lead shielding during fluoroscopy-guided kyphoplasty procedures as a way to reduce operator radiation exposure. An anthropomorphic phantom was used to mimic a patient undergoing a kyphoplasty procedure under fluoroscopic guidance. Radiation measurements of the air kerma rate (AKR) were made at several locations and under various experimental conditions. First, AKR was measured at various angles along the horizontal plane of the phantom and at varying distances from the phantom, both with and without a lead apron wrapped around the lower portion of the phantom (referred to here as phantom shielding). Second, the effect of an operator's apron was simulated by suspending a lead apron between the phantom and the measurement device. AKR was measured for the four shielding conditions - phantom shielding only, operator apron only, both phantom shielding and operator apron, and no shielding. Third, AKR measurements were made at various heights and with varying C-arm angle. At all locations, the phantom shielding provided no substantial protection beyond that provided by an operator's own lead apron. Phantom shielding did not reduce AKR at a height comparable to that of an operator's head. Previous reports of using patient shielding to reduce operator exposure fail to consider the role of an operator's own lead apron in radiation protection. For an operator wearing appropriate personal lead apparel, patient shielding provides no substantial reduction in operator dose. (orig.)

  6. Is lead shielding of patients necessary during fluoroscopic procedures? A study based on kyphoplasty

    International Nuclear Information System (INIS)

    Smith, Joshua R.; Marsh, Rebecca M.; Silosky, Michael S.

    2018-01-01

    To determine the benefits, risks, and limitations associated with wrapping a patient with lead shielding during fluoroscopy-guided kyphoplasty procedures as a way to reduce operator radiation exposure. An anthropomorphic phantom was used to mimic a patient undergoing a kyphoplasty procedure under fluoroscopic guidance. Radiation measurements of the air kerma rate (AKR) were made at several locations and under various experimental conditions. First, AKR was measured at various angles along the horizontal plane of the phantom and at varying distances from the phantom, both with and without a lead apron wrapped around the lower portion of the phantom (referred to here as phantom shielding). Second, the effect of an operator's apron was simulated by suspending a lead apron between the phantom and the measurement device. AKR was measured for the four shielding conditions - phantom shielding only, operator apron only, both phantom shielding and operator apron, and no shielding. Third, AKR measurements were made at various heights and with varying C-arm angle. At all locations, the phantom shielding provided no substantial protection beyond that provided by an operator's own lead apron. Phantom shielding did not reduce AKR at a height comparable to that of an operator's head. Previous reports of using patient shielding to reduce operator exposure fail to consider the role of an operator's own lead apron in radiation protection. For an operator wearing appropriate personal lead apparel, patient shielding provides no substantial reduction in operator dose. (orig.)

  7. Closed reduction and fluoroscopic-assisted percutaneous pinning of 42 physeal fractures in 37 dogs and 4 cats.

    Science.gov (United States)

    Boekhout-Ta, Christina L; Kim, Stanley E; Cross, Alan R; Evans, Richard; Pozzi, Antonio

    2017-01-01

    To report complications and clinical outcome of dogs and cats that underwent fluoroscopic-assisted percutaneous pinning (FAPP) of physeal fractures. Retrospective study. Client-owned dogs (n = 37) and cats (n = 4). Records (August 2007-August 2014) of physeal fractures treated with FAPP in 3 hospitals were evaluated. Data collected included signalment, fracture characteristics (etiology, location, duration, Salter-Harris classification, preoperative and postoperative displacement), surgical information (implant size, surgical duration), and outcome assessment information (functional outcome, radiographic outcome, and complications). The majority of animals (92%) were classified as full functional outcome. No significant predictors of functional outcome were identified. The overall complication rate was 15% (n = 6). Elective pin removal rate was 41% (n = 17). Goniometry and limb circumference measurements of the affected and contralateral limbs were not significantly different in dogs for which measurements were obtained. Seventeen of 18 animals (16 dogs, 2 cats) measured had bone length changes on follow-up radiographs. FAPP is associated with an excellent functional outcome in a narrow selection of fracture configurations, specifically those with minimal displacement and for which anatomical alignment can be achieved with closed reduction. © 2016 The American College of Veterinary Surgeons.

  8. Clinical significance of fluoroscopic patterns specific for the mitotic spindle in patients with reumatic diseases

    Directory of Open Access Journals (Sweden)

    S. Todesco

    2011-09-01

    Full Text Available Objective: we proposed to determine the clinical significance of anti-NuMA and anti-HsEg5 antibodies in a group of patients affected with rheumatic diseases. Materials and methods: indirect immunofluorescence on HEp-2000 cells at serum dilution of 1:40 was used to examin 26 sera which had previously showed a “mitotic spindle” fluoroscopic pattern type during laboratory routine. Results: 21 sera (80,7% were identified with NuMA and 5 (19,3% with HsEg5 patterns alone or associated with other ANA patterns. However only patients with isolated positiveness and that is 15 with NuMA and 4 with HsEg5 stainings were included in this study. Of the NuMA positive patients 5 were affected with arthropathies associated to different forms of thyroiditis, 2 with seronegative arthritis, 2 with antiphospholipid syndrome, 1 with systemic lupus erythematosus (SLE, 1 with rheumatoid arthritis, 1 with sicca syndrome, 1 with undifferentiated connective tissue disease, 1 with Mycoplasma pneumaniae infection and 1 with retinal thrombosis. Of the HsEg5 positive patients 3 were affected with SLE and 1 with seronegative arthritis. Conclusions: NuMA does not prevail in any defined rheumatic disease, while HsEg5 staining were more frequent (75% in patients affected with SLE all of whom showing high antibody titres.

  9. Occupational exposures during abdominal fluoroscopically guided interventional procedures for different patient sizes - A Monte Carlo approach.

    Science.gov (United States)

    Santos, William S; Belinato, Walmir; Perini, Ana P; Caldas, Linda V E; Galeano, Diego C; Santos, Carla J; Neves, Lucio P

    2018-01-01

    In this study we evaluated the occupational exposures during an abdominal fluoroscopically guided interventional radiology procedure. We investigated the relation between the Body Mass Index (BMI), of the patient, and the conversion coefficient values (CC) for a set of dosimetric quantities, used to assess the exposure risks of medical radiation workers. The study was performed using a set of male and female virtual anthropomorphic phantoms, of different body weights and sizes. In addition to these phantoms, a female and a male phantom, named FASH3 and MASH3 (reference virtual anthropomorphic phantoms), were also used to represent the medical radiation workers. The CC values, obtained as a function of the dose area product, were calculated for 87 exposure scenarios. In each exposure scenario, three phantoms, implemented in the MCNPX 2.7.0 code, were simultaneously used. These phantoms were utilized to represent a patient and medical radiation workers. The results showed that increasing the BMI of the patient, adjusted for each patient protocol, the CC values for medical radiation workers decrease. It is important to note that these results were obtained with fixed exposure parameters. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  10. Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: a report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council.

    Science.gov (United States)

    Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen; Fukuda, Atsushi; Goode, Allen; Hartwell, Gary; LaFrance, Terry; Nickoloff, Edward; Shepard, Jeff; Strauss, Keith

    2012-05-01

    Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology "automatic dose rate and image quality" (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were

  11. Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: A Report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council

    Energy Technology Data Exchange (ETDEWEB)

    Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen; Fukuda, Atsushi; Goode, Allen; Hartwell, Gary; LaFrance, Terry; Nickoloff, Edward; Shepard, Jeff; Strauss, Keith [Henry Ford Health System, Detroit, Michigan 48202 (United States); Beth Israel Deaconess Medical Center, Boston, Massachusetts 02115 (United States); Columbia University Medical Center, New York, New York 10032 (United States); Shiga Medical Center for Children, Moriyama City, Shiga-Ken, Japan 524-0022 (Japan); University of Virginia Health Science Center, Charlottesville, Virginia 22908 (United States); Baystate Health Systems, Inc., Springfield, Massachusetts 01199 (United States); Columbia University Medical Center, New York, New York 10032 (United States); University of Texas M.D. Anderson Cancer Center, Houston, Texas 77030 (United States); Cincinnati Children' s Hospital Medical Center, Cincinnati, Ohio 45229 (United States)

    2012-05-15

    Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which

  12. Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: A Report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council

    International Nuclear Information System (INIS)

    Rauch, Phillip; Lin, Pei-Jan Paul; Balter, Stephen; Fukuda, Atsushi; Goode, Allen; Hartwell, Gary; LaFrance, Terry; Nickoloff, Edward; Shepard, Jeff; Strauss, Keith

    2012-01-01

    Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were

  13. The ALARA (as low as reasonably achievable) concept in pediatric interventional and fluoroscopic imaging: striving to keep radiation doses as low as possible during fluoroscopy of pediatric patients - a white paper executive summary

    International Nuclear Information System (INIS)

    Strauss, Keith J.; Kaste, Sue C.

    2006-01-01

    ALARA represents a practice mandate adhering to the principle of keeping radiation doses to patients and personnel As Low As Reasonably Achievable. This concept is strongly endorsed by the Society for Pediatric Radiology, particularly in the use of procedures and modalities involving higher radiation doses such as CT and fluoroscopic examinations of pediatric patients. There is no doubt that medical imaging, which has undergone tremendous technological advances in recent decades, is integral to patient care. However, these technological advances generally precede the knowledge of end-users concerning the optimal use and correct operation of the resulting imaging equipment, and such knowledge is essential to minimizing potential risks to the patients. Current imaging methods must be optimized for radiation dose reduction in pediatric patients who might be as much as ten times more radiosensitive than adults. Unlike straightforward radiographic examinations, radiation dose to the patient during fluoroscopy is dependent on the operator's training, experience with the fluoroscope, and efficiency in completing a diagnostic study. The range of pediatric radiation doses from fluoroscopy is wide because this examination is performed not only by pediatric radiologists but also by general radiologists who occasionally care for children, interventional cardiologists, gastroenterologists, urologists and others. Thus, a venue where multidisciplinary interaction by this variety of operators can occur serves to improve pediatric patient care

  14. SU-G-BRA-05: Application of a Feature-Based Tracking Algorithm to KV X-Ray Fluoroscopic Images Toward Marker-Less Real-Time Tumor Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, M; Matsuo, Y; Mukumoto, N; Iizuka, Y; Yokota, K; Mizowaki, T; Hiraoka, M [Kyoto University, Graduate School of Medicine, Kyoto (Japan); Nakao, M [Kyoto University, Graduate School of Informatics, Kyoto (Japan)

    2016-06-15

    Purpose: To detect target position on kV X-ray fluoroscopic images using a feature-based tracking algorithm, Accelerated-KAZE (AKAZE), for markerless real-time tumor tracking (RTTT). Methods: Twelve lung cancer patients treated with RTTT on the Vero4DRT (Mitsubishi Heavy Industries, Japan, and Brainlab AG, Feldkirchen, Germany) were enrolled in this study. Respiratory tumor movement was greater than 10 mm. Three to five fiducial markers were implanted around the lung tumor transbronchially for each patient. Before beam delivery, external infrared (IR) markers and the fiducial markers were monitored for 20 to 40 s with the IR camera every 16.7 ms and with an orthogonal kV x-ray imaging subsystem every 80 or 160 ms, respectively. Target positions derived from the fiducial markers were determined on the orthogonal kV x-ray images, which were used as the ground truth in this study. Meanwhile, tracking positions were identified by AKAZE. Among a lot of feature points, AKAZE found high-quality feature points through sequential cross-check and distance-check between two consecutive images. Then, these 2D positional data were converted to the 3D positional data by a transformation matrix with a predefined calibration parameter. Root mean square error (RMSE) was calculated to evaluate the difference between 3D tracking and target positions. A total of 393 frames was analyzed. The experiment was conducted on a personal computer with 16 GB RAM, Intel Core i7-2600, 3.4 GHz processor. Results: Reproducibility of the target position during the same respiratory phase was 0.6 +/− 0.6 mm (range, 0.1–3.3 mm). Mean +/− SD of the RMSEs was 0.3 +/− 0.2 mm (range, 0.0–1.0 mm). Median computation time per frame was 179 msec (range, 154–247 msec). Conclusion: AKAZE successfully and quickly detected the target position on kV X-ray fluoroscopic images. Initial results indicate that the differences between 3D tracking and target position would be clinically acceptable.

  15. SU-G-BRA-05: Application of a Feature-Based Tracking Algorithm to KV X-Ray Fluoroscopic Images Toward Marker-Less Real-Time Tumor Tracking

    International Nuclear Information System (INIS)

    Nakamura, M; Matsuo, Y; Mukumoto, N; Iizuka, Y; Yokota, K; Mizowaki, T; Hiraoka, M; Nakao, M

    2016-01-01

    Purpose: To detect target position on kV X-ray fluoroscopic images using a feature-based tracking algorithm, Accelerated-KAZE (AKAZE), for markerless real-time tumor tracking (RTTT). Methods: Twelve lung cancer patients treated with RTTT on the Vero4DRT (Mitsubishi Heavy Industries, Japan, and Brainlab AG, Feldkirchen, Germany) were enrolled in this study. Respiratory tumor movement was greater than 10 mm. Three to five fiducial markers were implanted around the lung tumor transbronchially for each patient. Before beam delivery, external infrared (IR) markers and the fiducial markers were monitored for 20 to 40 s with the IR camera every 16.7 ms and with an orthogonal kV x-ray imaging subsystem every 80 or 160 ms, respectively. Target positions derived from the fiducial markers were determined on the orthogonal kV x-ray images, which were used as the ground truth in this study. Meanwhile, tracking positions were identified by AKAZE. Among a lot of feature points, AKAZE found high-quality feature points through sequential cross-check and distance-check between two consecutive images. Then, these 2D positional data were converted to the 3D positional data by a transformation matrix with a predefined calibration parameter. Root mean square error (RMSE) was calculated to evaluate the difference between 3D tracking and target positions. A total of 393 frames was analyzed. The experiment was conducted on a personal computer with 16 GB RAM, Intel Core i7-2600, 3.4 GHz processor. Results: Reproducibility of the target position during the same respiratory phase was 0.6 +/− 0.6 mm (range, 0.1–3.3 mm). Mean +/− SD of the RMSEs was 0.3 +/− 0.2 mm (range, 0.0–1.0 mm). Median computation time per frame was 179 msec (range, 154–247 msec). Conclusion: AKAZE successfully and quickly detected the target position on kV X-ray fluoroscopic images. Initial results indicate that the differences between 3D tracking and target position would be clinically acceptable.

  16. Transverse morphology of the sacroiliac joint: effect of angulation and implications for fluoroscopically guided sacroiliac joint injection

    International Nuclear Information System (INIS)

    Ling, B.C.; Lee, J.W.; Man, H.S.J.; Grace, M.G.A.; Lambert, R.G.W.; Jhangri, G.S.

    2006-01-01

    Effects of angulation of computed tomography (CT) reconstruction plane on sacroiliac (SI) joint morphology were studied, and factors influencing the approach to fluoroscopically guided SI joint injection were assessed. CT scans of pelvises were reformatted on 41 subjects, aged 51.7 (±15.1) years. Transverse images were reconstructed at the caudal 3 cm of the SI joint tilting plane of reconstruction from -30 to +30 at 15 increments. Anteroposterior diameter of joint (depth), angle from sagittal plane (orientation angle), and distance from skin were measured. Joint contour was classified, and presence of bone blocking access to the joint was recorded. Comparison between angles were analysed by t-test. Relationships between variables were assessed by a Pearson correlation test. Depth was shorter with angulation in the inferior direction (P<0.01). Orientation angle increased with superior angulation (P<0.01). Distance from skin increased (P<0.01) with angulation in either direction. Joint contour was significantly different from baseline at each angle (P<0.001) but highly variable. Inferior angulation resulted in interposition of ilium between skin and SI joint, and superior angulation caused bone block due to the lower sacrum. None of these features was identified without tilting of the reconstruction plane, and effects were more pronounced with steeper angulation

  17. Transverse morphology of the sacroiliac joint: effect of angulation and implications for fluoroscopically guided sacroiliac joint injection

    Energy Technology Data Exchange (ETDEWEB)

    Ling, B.C.; Lee, J.W.; Man, H.S.J.; Grace, M.G.A.; Lambert, R.G.W. [Department of Radiology and Diagnostic Imaging, University of Alberta Hospital, Edmonton (Canada); Jhangri, G.S. [Department of Public Health Sciences, University of Alberta Hospital, Edmonton (Canada)

    2006-11-15

    Effects of angulation of computed tomography (CT) reconstruction plane on sacroiliac (SI) joint morphology were studied, and factors influencing the approach to fluoroscopically guided SI joint injection were assessed. CT scans of pelvises were reformatted on 41 subjects, aged 51.7 ({+-}15.1) years. Transverse images were reconstructed at the caudal 3 cm of the SI joint tilting plane of reconstruction from -30 to +30 at 15 increments. Anteroposterior diameter of joint (depth), angle from sagittal plane (orientation angle), and distance from skin were measured. Joint contour was classified, and presence of bone blocking access to the joint was recorded. Comparison between angles were analysed by t-test. Relationships between variables were assessed by a Pearson correlation test. Depth was shorter with angulation in the inferior direction (P<0.01). Orientation angle increased with superior angulation (P<0.01). Distance from skin increased (P<0.01) with angulation in either direction. Joint contour was significantly different from baseline at each angle (P<0.001) but highly variable. Inferior angulation resulted in interposition of ilium between skin and SI joint, and superior angulation caused bone block due to the lower sacrum. None of these features was identified without tilting of the reconstruction plane, and effects were more pronounced with steeper angulation.

  18. Patient and staff doses in fluoroscopically guided invasive diagnostic and interventional urology procedures

    International Nuclear Information System (INIS)

    Ivanova, D.; Hristova-Popova, J.; Avramova-Cholakova, S.; Deyanova, Ts.; Dobrikov, R.

    2015-01-01

    Full text: The aim of this study is to evaluate patient and staff doses in fluoroscopically guided invasive diagnostic and interventional urology procedures. All the data were collected in the Emergency Hospital 'N. I. Pirogov'. While recording data for the patients, a real time dosimetry measurement of the medical staff was made. Air kerma-area product (KAP) was recorded for intravenous pyelogram (IVP), percutaneous nephrostomy (PN) and ureteral 'double-J' stenting. Patient data sex, age and weight were also taken. Staff doses were estimated with the system RaySafe i2. It contains four dosimeters, with a wireless connection to a real time display. The dosimeters were worn on the unprotected upper part of the body and measured the personal dose equivalent Hp(10). The mean KAP values for the procedures are: 3.21 Gy.cm 2 for IVP, 10.37 Gy.cm 2 for PN and 4.15 Gy.cm 2 for 'double-J' respectively. The highest staff dose for PN and 'double-J' is received by the urologist (160 μSv and 47.3 μSv, respectively), while for the IVP the radiographer has the highest exposure (20 μSv). Each member of the medical staff was on a different position in respect to the X-ray tube and the patient, which is the main reason for the differences in the staff doses. The variations in the mean patient and staff doses are mostly due to the interventions themselves, their complexity and the individual treatment of every patient. RaySafe i2 is very useful as guideline for making a choice of a better position and in the decreasing of radiation exposure to the staff

  19. Fluoroscopic study of the normal gastrointestinal motility and measurements in the Hispaniolan Amazon parrot (Amazona ventralis).

    Science.gov (United States)

    Beaufrère, Hugues; Nevarez, Javier; Taylor, W Michael; Jankowski, Gwendolyn; Rademacher, Nathalie; Gaschen, Lorrie; Pariaut, Romain; Tully, Thomas N

    2010-01-01

    Contrast fluoroscopy is a valuable tool to examine avian gastrointestinal motility. However, the lack of a standardized examination protocol and reference ranges prevents the objective interpretation of motility disorders and other gastrointestinal abnormalities. Our goals were to evaluate gastrointestinal motility in 20 Hispaniolan Amazon parrots (Amazona ventralis) by contrast fluoroscopy. Each parrot was crop-fed an equal part mixture of barium sulfate and hand-feeding formula and placed in a cardboard box for fluoroscopy. Over a 3-h period, 1.5 minute segments of lateral and ventrodorsal fluoroscopy were recorded every 30 min. The gastric cycle and patterns of intestinal motility were described. The frequency of crop contractions, esophageal boluses, and gastric cycles were determined in lateral and ventrodorsal views. A range of 3.4-6.6 gastric cycles/min was noted on the lateral view and 3.0-6.6 gastric cycles/min on the ventrodorsal view. Circular measurements of the proventriculus diameter, ventriculus width, and length were obtained using the midshaft femoral diameter as a standard reference unit. The upper limits of the reference ranges were 3.6 and 4.7 femoral units for the proventriculus diameter in the lateral and ventrodorsal view, respectively. Two consecutive measurements were obtained and the measurement technique was found to have high reproducibility. In this study, we established a standardized protocol for contrast fluoroscopic examination of the gastrointestinal tract and a reliable measurement method of the proventriculus and ventriculus using femoral units in the Hispaniolan Amazon parrot.

  20. Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and detector characteristics.

    Science.gov (United States)

    Jain, Amit; Kuhls-Gilcrist, Andrew T; Gupta, Sandesh K; Bednarek, Daniel R; Rudin, Stephen

    2010-03-01

    The MTF, NNPS, and DQE are standard linear system metrics used to characterize intrinsic detector performance. To evaluate total system performance for actual clinical conditions, generalized linear system metrics (GMTF, GNNPS and GDQE) that include the effect of the focal spot distribution, scattered radiation, and geometric unsharpness are more meaningful and appropriate. In this study, a two-dimensional (2D) generalized linear system analysis was carried out for a standard flat panel detector (FPD) (194-micron pixel pitch and 600-micron thick CsI) and a newly-developed, high-resolution, micro-angiographic fluoroscope (MAF) (35-micron pixel pitch and 300-micron thick CsI). Realistic clinical parameters and x-ray spectra were used. The 2D detector MTFs were calculated using the new Noise Response method and slanted edge method and 2D focal spot distribution measurements were done using a pin-hole assembly. The scatter fraction, generated for a uniform head equivalent phantom, was measured and the scatter MTF was simulated with a theoretical model. Different magnifications and scatter fractions were used to estimate the 2D GMTF, GNNPS and GDQE for both detectors. Results show spatial non-isotropy for the 2D generalized metrics which provide a quantitative description of the performance of the complete imaging system for both detectors. This generalized analysis demonstrated that the MAF and FPD have similar capabilities at lower spatial frequencies, but that the MAF has superior performance over the FPD at higher frequencies even when considering focal spot blurring and scatter. This 2D generalized performance analysis is a valuable tool to evaluate total system capabilities and to enable optimized design for specific imaging tasks.

  1. Upper cervical spine movement during intubation: fluoroscopic comparison of the AirWay Scope, McCoy laryngoscope, and Macintosh laryngoscope.

    Science.gov (United States)

    Maruyama, K; Yamada, T; Kawakami, R; Kamata, T; Yokochi, M; Hara, K

    2008-01-01

    The AirWay Scope (AWS) is a new fibreoptic intubation device, which allows visualization of the glottic structures without alignment of the oral, pharyngeal, and tracheal axes, and thus may be useful in patients with limited cervical spine (C-spine) movement. We fluoroscopically evaluated upper C-spine movement during intubation with the AWS or Macintosh or McCoy laryngoscope. Forty-five patients, with normal C-spine, scheduled for elective surgery were randomly assigned to one of the three intubation devices. Movement of the upper C-spine was examined by measuring angles formed by adjacent vertebrae during intubation. Time to intubation was also recorded. Median cumulative upper C-spine movement was 22.3 degrees, 32.3 degrees, and 36.5 degrees with the AWS, Macintosh laryngoscope, and McCoy laryngoscope, respectively (Pmovement of the C-spine at C1/C2 in comparison with the Macintosh or McCoy laryngoscope (P=0.012), and at C3/C4 in comparison with the McCoy laryngoscope (P=0.019). Intubation time was significantly longer in the AWS group than in the Macintosh group (P=0.03). Compared with the Macintosh or McCoy laryngoscope, the AWS produced less movement of upper C-spine for intubation in patients with a normal C-spine.

  2. TH-E-209-01: Fluoroscopic Dose Monitoring and Patient Follow-Up Program at Massachusetts General Hospital

    International Nuclear Information System (INIS)

    Liu, B.

    2016-01-01

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

  3. TH-E-209-01: Fluoroscopic Dose Monitoring and Patient Follow-Up Program at Massachusetts General Hospital

    Energy Technology Data Exchange (ETDEWEB)

    Liu, B. [Massachusetts General Hospital (United States)

    2016-06-15

    Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

  4. Fluoroscopic-guided radiofrequency ablation of the basivertebral nerve: application and analysis with multiple imaging modalities in an ovine model (Invited Paper)

    Science.gov (United States)

    Bergeron, Jeffrey A.; Eskey, Cliff J.; Attawia, Mohammed; Patel, Samit J.; Ryan, Thomas P.; Pellegrino, Richard; Sutton, Jeffrey; Crombie, John; Paul, B. T.; Hoopes, P. J.

    2005-04-01

    Pathologic involvement of the basivertebral nerve, an intraosseous vertebral nerve found in humans and most mammalian species, may play a role in some forms of back pain. This study was designed to assess the feasibility and effects of the percutaneous delivery of radiofrequency (RF) energy to thermally ablate the basivertebral nerve in the lumbar vertebrae of mature sheep. Using fluoroscopic guidance, a RF bipolar device was placed and a thermal dose delivered to lumbar vertebral bodies in sheep. Post-treatment assessment included multiple magnetic resonance imaging (MRI) techniques and computed tomography (CT). These data were analyzed and correlated to histopathology and morphometry findings to describe the cellular and boney structural changes resulting from the treatment. Imaging modalities MRI and CT can be implemented to non-invasively describe treatment region and volume, marrow cellular effects, and bone density alterations immediately following RF treatment and during convalescence. Such imaging can be utilized to assess treatment effects and refine the thermal dose to vertebral body volume ratio used in treatment planning. This information will be used to improve the therapeutic ratio and develop a treatment protocol for human applications.

  5. Mortality from breast cancer after irradiation during fluoroscopic examinations in patients being treated for tuberculosis

    International Nuclear Information System (INIS)

    Miller, A.B.; Howe, G.R.; Sherman, G.J.; Lindsay, J.P.; Yaffe, M.J.; Dinner, P.J.; Risch, H.A.; Preston, D.L.

    1989-01-01

    The increasing use of mammography to screen asymptomatic women makes it important to know the risk of breast cancer associated with exposure to low levels of ionizing radiation. We examined the mortality from breast cancer in a cohort of 31,710 women who had been treated for tuberculosis at Canadian sanatoriums between 1930 and 1952. A substantial proportion (26.4 percent) had received radiation doses to the breast of 10 cGy or more from repeated fluoroscopic examinations during therapeutic pneumothoraxes. Women exposed to greater than or equal to 10 cGy of radiation had a relative risk of death from breast cancer of 1.36, as compared with those exposed to less than 10 cGy (95 percent confidence interval, 1.11 to 1.67; P = 0.001). The data were most consistent with a linear dose-response relation. The risk was greatest among women who had been exposed to radiation when they were between 10 and 14 years of age; they had a relative risk of 4.5 per gray, and an additive risk of 6.1 per 10(4) person-years per gray. With increasing age at first exposure, there was substantially less excess risk, and the radiation effect appeared to peak approximately 25 to 34 years after the first exposure. Our additive model for lifetime risk predicts that exposure to 1 cGy at the age of 40 increases the number of deaths from breast cancer by 42 per million women. We conclude that the risk of breast cancer associated with radiation decreases sharply with increasing age at exposure and that even a small benefit to women of screening mammography would outweigh any possible risk of radiation-induced breast cancer

  6. Contrast-enhanced MR angiography of the carotid artery using 3D time-resolved imaging of contrast kinetics. Comparison with real-time fluoroscopic triggered 3D-elliptical centric view ordering

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Koshikawa, Tokiko; Fukatsu, Hiroshi; Sakurai, Yasuo; Ishiguchi, Tsuneo; Ishigaki, Takeo; Ichinose, Nobuyasu

    2001-01-01

    The purpose of this study was to evaluate contrast-enhanced MR angiography using the 3D time-resolved imaging of contrast kinetics technique (3D-TRICKS) by direct comparison with the fluoroscopic triggered 3D-elliptical centric view ordering (3D-ELLIP) technique. 3D-TRICKS and 3D-ELLIP were directly compared on a 1.5-Tesla MR unit using the same spatial resolution and matrix. In 3D-TRICKS, the central part of the k-space is updated more frequently than the peripheral part of the k-space, which is divided in the slice-encoding direction. The carotid arteries were imaged using 3D-TRICKS and 3D-ELLIP sequentially in 14 patients. Temporal resolution was 12 sec for 3D-ELLIP and 6 sec for 3D-TRICKS. The signal-to-noise ratio (S/N) of the common carotid artery was measured, and the quality of MIP images was then scored in terms of venous overlap and blurring of vessel contours. No significant difference in mean S/N was seen between the two methods. Significant venous overlap was not seen in any of the patients examined. Moderate blurring of vessel contours was noted on 3D-TRICKS in five patients and on 3D-ELLIP in four patients. Blurring in the slice-encoding direction was slightly more pronounced in 3D-TRICKS. However, qualitative analysis scores showed no significant differences. When the spatial resolution of the two methods was identical, the performance of 3D-TRICKS was found to be comparable in static visualization of the carotid arteries with 3D-ELLIP, although blurring in the slice-encoding direction was slightly more pronounced in 3D-TRICKS. 3D-TRICKS is a more robust technique than 3D-ELLIP, because 3D-ELLIP requires operator-dependent fluoroscopic triggering. Furthermore, 3D-TRICKS can achieve higher temporal resolution. For the spatial resolution employed in this study, 3D-TRICKS may be the method of choice. (author)

  7. Investigation of first ray mobility during gait by kinematic fluoroscopic imaging-a novel method

    Directory of Open Access Journals (Sweden)

    Martin Heiner

    2012-02-01

    Full Text Available Abstract Background It is often suggested that sagittal instability at the first tarso-metatarsal joint level is a primary factor for hallux valgus and that sagittal instability increases with the progression of the deformity. The assessment of the degree of vertical instability is usually made by clinical evaluation while any measurements mostly refer to a static assessment of medial ray mobility (i.e. the plantar/dorsal flexion in the sagittal plane. Testing methods currently available cannot attribute the degree of mobility to the corresponding anatomical joints making up the medial column of the foot. The aim of this study was to develop a technique which allows for a quantification of the in-vivo sagittal mobility of the joints of the medial foot column during the roll-over process under full weight bearing. Methods Mobility of first ray bones was investigated by dynamic distortion-free fluoroscopy (25 frames/s of 14 healthy volunteers and 8 patients with manifested clinical instability of the first ray. A CAD-based evaluation method allowed the determination of mobility and relative displacements and rotations of the first ray bones within the sagittal plane during the stance phase of gait. Results Total flexion of the first ray was found to be 13.63 (SD 6.14 mm with the healthy volunteers and 13.06 (SD 8.01 mm with the patients (resolution: 0.245 mm/pixel. The dorsiflexion angle was 5.27 (SD 2.34 degrees in the healthy volunteers and increased to 5.56 (SD 3.37 degrees in the patients. Maximum rotations were found at the naviculo-cuneiform joints and least at the first tarso-metatarsal joint level in both groups. Conclusions Dynamic fluoroscopic assessment has been shown to be a valuable tool for characterisation of the kinematics of the joints of the medial foot column during gait. A significant difference in first ray flexion and angular rotation between the patients and healthy volunteers however could not be found.

  8. SU-E-I-40: New Method for Measurement of Task-Specific, High-Resolution Detector System Performance

    Energy Technology Data Exchange (ETDEWEB)

    Loughran, B; Singh, V; Jain, A; Bednarek, D; Rudin, S [University at Buffalo, Buffalo, NY (United States)

    2014-06-01

    Purpose: Although generalized linear system analytic metrics such as GMTF and GDQE can evaluate performance of the whole imaging system including detector, scatter and focal-spot, a simplified task-specific measured metric may help to better compare detector systems. Methods: Low quantum-noise images of a neuro-vascular stent with a modified ANSI head phantom were obtained from the average of many exposures taken with the high-resolution Micro-Angiographic Fluoroscope (MAF) and with a Flat Panel Detector (FPD). The square of the Fourier Transform of each averaged image, equivalent to the measured product of the system GMTF and the object function in spatial-frequency space, was then divided by the normalized noise power spectra (NNPS) for each respective system to obtain a task-specific generalized signal-to-noise ratio. A generalized measured relative object detectability (GM-ROD) was obtained by taking the ratio of the integral of the resulting expressions for each detector system to give an overall metric that enables a realistic systems comparison for the given detection task. Results: The GM-ROD provides comparison of relative performance of detector systems from actual measurements of the object function as imaged by those detector systems. This metric includes noise correlations and spatial frequencies relevant to the specific object. Additionally, the integration bounds for the GM-ROD can be selected to emphasis the higher frequency band of each detector if high-resolution image details are to be evaluated. Examples of this new metric are discussed with a comparison of the MAF to the FPD for neuro-vascular interventional imaging. Conclusion: The GM-ROD is a new direct-measured task-specific metric that can provide clinically relevant comparison of the relative performance of imaging systems. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

  9. A moving fluoroscope to capture tibiofemoral kinematics during complete cycles of free level and downhill walking as well as stair descent.

    Directory of Open Access Journals (Sweden)

    Renate List

    Full Text Available Videofluoroscopy has been shown to provide essential information in the evaluation of the functionality of total knee arthroplasties. However, due to the limitation in the field of view, most systems can only assess knee kinematics during highly restricted movements. To avoid the limitations of a static image intensifier, a moving fluoroscope has been presented as a standalone system that allows tracking of the knee during multiple complete cycles of level- and downhill-walking, as well as stair descent, in combination with the synchronous assessment of ground reaction forces and whole body skin marker measurements. Here, we assess the ability of the system to keep the knee in the field of view of the image intensifier. By measuring ten total knee arthroplasty subjects, we demonstrate that it is possible to maintain the knee to within 1.8 ± 1.4 cm vertically and 4.0 ± 2.6 cm horizontally of the centre of the intensifier throughout full cycles of activities of daily living. Since control of the system is based on real-time feedback of a wire sensor, the system is not dependent on repeatable gait patterns, but is rather able to capture pathological motion patterns with low inter-trial repeatability.

  10. A moving fluoroscope to capture tibiofemoral kinematics during complete cycles of free level and downhill walking as well as stair descent.

    Science.gov (United States)

    List, Renate; Postolka, Barbara; Schütz, Pascal; Hitz, Marco; Schwilch, Peter; Gerber, Hans; Ferguson, Stephen J; Taylor, William R

    2017-01-01

    Videofluoroscopy has been shown to provide essential information in the evaluation of the functionality of total knee arthroplasties. However, due to the limitation in the field of view, most systems can only assess knee kinematics during highly restricted movements. To avoid the limitations of a static image intensifier, a moving fluoroscope has been presented as a standalone system that allows tracking of the knee during multiple complete cycles of level- and downhill-walking, as well as stair descent, in combination with the synchronous assessment of ground reaction forces and whole body skin marker measurements. Here, we assess the ability of the system to keep the knee in the field of view of the image intensifier. By measuring ten total knee arthroplasty subjects, we demonstrate that it is possible to maintain the knee to within 1.8 ± 1.4 cm vertically and 4.0 ± 2.6 cm horizontally of the centre of the intensifier throughout full cycles of activities of daily living. Since control of the system is based on real-time feedback of a wire sensor, the system is not dependent on repeatable gait patterns, but is rather able to capture pathological motion patterns with low inter-trial repeatability.

  11. A moving fluoroscope to capture tibiofemoral kinematics during complete cycles of free level and downhill walking as well as stair descent

    Science.gov (United States)

    Postolka, Barbara; Schütz, Pascal; Hitz, Marco; Schwilch, Peter; Gerber, Hans

    2017-01-01

    Videofluoroscopy has been shown to provide essential information in the evaluation of the functionality of total knee arthroplasties. However, due to the limitation in the field of view, most systems can only assess knee kinematics during highly restricted movements. To avoid the limitations of a static image intensifier, a moving fluoroscope has been presented as a standalone system that allows tracking of the knee during multiple complete cycles of level- and downhill-walking, as well as stair descent, in combination with the synchronous assessment of ground reaction forces and whole body skin marker measurements. Here, we assess the ability of the system to keep the knee in the field of view of the image intensifier. By measuring ten total knee arthroplasty subjects, we demonstrate that it is possible to maintain the knee to within 1.8 ± 1.4 cm vertically and 4.0 ± 2.6 cm horizontally of the centre of the intensifier throughout full cycles of activities of daily living. Since control of the system is based on real-time feedback of a wire sensor, the system is not dependent on repeatable gait patterns, but is rather able to capture pathological motion patterns with low inter-trial repeatability. PMID:29016647

  12. Intra-operative fiducial-based CT/fluoroscope image registration framework for image-guided robot-assisted joint fracture surgery.

    Science.gov (United States)

    Dagnino, Giulio; Georgilas, Ioannis; Morad, Samir; Gibbons, Peter; Tarassoli, Payam; Atkins, Roger; Dogramadzi, Sanja

    2017-08-01

    Joint fractures must be accurately reduced minimising soft tissue damages to avoid negative surgical outcomes. To this regard, we have developed the RAFS surgical system, which allows the percutaneous reduction of intra-articular fractures and provides intra-operative real-time 3D image guidance to the surgeon. Earlier experiments showed the effectiveness of the RAFS system on phantoms, but also key issues which precluded its use in a clinical application. This work proposes a redesign of the RAFS's navigation system overcoming the earlier version's issues, aiming to move the RAFS system into a surgical environment. The navigation system is improved through an image registration framework allowing the intra-operative registration between pre-operative CT images and intra-operative fluoroscopic images of a fractured bone using a custom-made fiducial marker. The objective of the registration is to estimate the relative pose between a bone fragment and an orthopaedic manipulation pin inserted into it intra-operatively. The actual pose of the bone fragment can be updated in real time using an optical tracker, enabling the image guidance. Experiments on phantom and cadavers demonstrated the accuracy and reliability of the registration framework, showing a reduction accuracy (sTRE) of about [Formula: see text] (phantom) and [Formula: see text] (cadavers). Four distal femur fractures were successfully reduced in cadaveric specimens using the improved navigation system and the RAFS system following the new clinical workflow (reduction error [Formula: see text], [Formula: see text]. Experiments showed the feasibility of the image registration framework. It was successfully integrated into the navigation system, allowing the use of the RAFS system in a realistic surgical application.

  13. Training Distal Locking Screw Insertion Skills to Novice Trainees: A Comparison Between Fluoroscopic- and Electromagnetic-Guided Techniques.

    Science.gov (United States)

    Leroux, Timothy; Khoshbin, Amir; Nousiainen, Markku T

    2015-10-01

    To compare the effect fluoroscopy or electromagnetic (EM) guidance has on the learning of locking screw insertion in tibial nails in surgical novices. A randomized, prospective, controlled trial was conducted involving 18 surgical trainees with no prior experience inserting locking screws in intramedullary nails. After a training session using fluoroscopy, participants underwent a pretest using fluoroscopic guidance. Participants were then randomized into either the fluoroscopy or EM group and were further trained using their respective technique. Post, retention, and transfer tests were conducted. Outcomes included task completion, drill attempts, screw changes, and radiation time. Intragroup comparisons revealed that the EM group used significantly less drill attempts during the post and retention tests compared with the pretest (P = 0.016 and P = 0.016, respectively). Intergroup comparisons revealed that the EM group was (1) more likely to complete the task during the retention test (P = 0.043) and (2) had significantly less radiation time during the post and retention tests (P = 0.002 and P = 0.003, respectively). Radiation time in the EM group during the transfer test increased to a level equal to what the fluoroscopy group used during the post and retention tests (P = 0.71 and P = 0.92, respectively). No other significant between-group differences occurred. EM guidance may be safely used to assist in the training of surgical novices in the skill of distal locking screw insertion. Not only does this technology significantly improve the ability to complete the task and decrease radiation use but also it does so without compromising skill acquisition. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  14. Detection of organ movement in cervix cancer patients using a fluoroscopic electronic portal imaging device and radiopaque markers

    International Nuclear Information System (INIS)

    Kaatee, Robert S.J.P.; Olofsen, Manouk J.J.; Verstraate, Marjolein B.J.; Quint, Sandra; Heijmen, Ben J.M.

    2002-01-01

    Purpose: To investigate the use of a fluoroscopic electronic portal imaging device (EPID) and radiopaque markers to detect internal cervix movement. Methods and Materials: For 10 patients with radiopaque markers clamped to the cervix, electronic portal images were made during external beam irradiation. Bony structures and markers in the portal images were registered with the same structures in the corresponding digitally reconstructed radiographs of the planning computed tomogram. Results: The visibility of the markers in the portal images was good, but their fixation should be improved. Generally, the correlation between bony structure displacements and marker movement was poor, the latter being substantially larger. The standard deviations describing the systematic and random bony anatomy displacements were 1.2 and 2.6 mm, 1.7 and 2.9 mm, and 1.6 and 2.7 mm in the lateral, cranial-caudal, and dorsal-ventral directions, respectively. For the marker movement those values were 3.4 and 3.4 mm, 4.3 and 5.2 mm, 3.2 and 5.2 mm, respectively. Estimated clinical target volume to planning target volume (CTV-PTV) planning margins (∼11 mm) based on the observed overall marker displacements (bony anatomy + internal cervix movement) are only marginally larger than the margins required to account for internal marker movement alone. Conclusions: With our current patient setup techniques and methods of setup verification and correction, the required CTV-PTV margins are almost fully determined by internal organ motion. Setup verification and correction using radiopaque markers might allow decreasing those margins, but technical improvements are needed

  15. Fluoroscopically Guided Sacroiliac Joint Injections: Comparison of the Effects of Intraarticular and Periarticular Injections on Immediate and Short-Term Pain Relief.

    Science.gov (United States)

    Nacey, Nicholas C; Patrie, James T; Fox, Michael G

    2016-11-01

    The purpose of this study was to determine whether intraarticular sacroiliac joint injections provide greater immediate and short-term pain relief than periarticular sacroiliac joint injections do. The records of all fluoroscopically guided sacroiliac joint injections performed over a 4-year period were identified. Patients who received an injection of 0.5 mL of bupivacaine and 0.5 mL (20 mg) of triamcinolone and who had preinjection, immediate, and 1-week postinjection pain scores (0-10 numeric scale) were included. Images from the procedures were retrospectively reviewed by two musculoskeletal radiologists to determine intraarticular or periarticular administration of the injection with discrepancies resolved by consensus. One hundred thirteen injections in 99 patients (65 women, 34 men; mean age, 59.4 years) met the inclusion criteria. There were 55 intraarticular and 58 periarticular injections. The mean preinjection, immediate, and 1-week postinjection pain scores for the intraarticular injections were 6.0, 1.6, and 4.1 and for the periarticular injections were 6.1, 2.0, and 4.2. The mean immediate and 1-week postinjection pain reduction were statistically significant in both groups (p sacroiliac joint injections provide statistically significant immediate and 1-week postinjection pain relief, no significant difference in the degree of pain relief achieved with intraarticular and periarticular injections was noted.

  16. Accuracy of CT chest without oral contrast for ruling out esophageal perforation using fluoroscopic esophagography as reference standard: a retrospective study.

    Science.gov (United States)

    Awais, Muhammad; Qamar, Saqib; Rehman, Abdul; Baloch, Noor Ul-Ain; Shafqat, Gulnaz

    2018-02-26

    Esophageal perforation has a high mortality rate. Fluoroscopic esophagography (FE) is the procedure of choice for diagnosing esophageal perforation. However, FE can be difficult to perform in seriously ill patients. We retrospectively reviewed charts and scans of all patients who had undergone thoracic CT (TCT) without oral contrast and FE for suspicion of esophageal perforation at our hospital between October, 2010 and December, 2015. Scans were interpreted by a single consultant radiologist having > 5 years of relevant experience. Statistical analysis was performed using SPSS version 20. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of TCT were computed using FE as reference standard. Of 122 subjects, 106 (83%) were male and their median age was 42 [inter-quartile range (IQR) 29-53] years. Esophageal perforation was evident on FE in 15 (8%) cases. Sensitivity, specificity, PPV and NPV of TCT for detecting esophageal perforation were 100, 54.6, 23.4 and 100%, respectively. When TCT was negative (n = 107), an alternative diagnosis was evident in 65 cases. Thoracic computed tomography (TCT) had 100% sensitivity and negative predictive value for excluding esophageal perforation. FE may be omitted in patients who have no evidence of mediastinal collection, pneumomediastinum or esophageal wall defect on TCT. However, in the presence of any of these features, FE is still necessary to confirm or exclude the presence of an esophageal perforation.

  17. Rationale and design of the NO-PARTY trial: near-zero fluoroscopic exposure during catheter ablation of supraventricular arrhythmias in young patients.

    Science.gov (United States)

    Casella, Michela; Dello Russo, Antonio; Pelargonio, Gemma; Bongiorni, Maria Grazia; Del Greco, Maurizio; Piacenti, Marcello; Andreassi, Maria Grazia; Santangeli, Pasquale; Bartoletti, Stefano; Moltrasio, Massimo; Fassini, Gaetano; Marini, Massimiliano; Di Cori, Andrea; Di Biase, Luigi; Fiorentini, Cesare; Zecchi, Paolo; Natale, Andrea; Picano, Eugenio; Tondo, Claudio

    2012-10-01

    Radiofrequency catheter ablation is the mainstay of therapy for supraventricular tachyarrhythmias. Conventional radiofrequency catheter ablation requires the use of fluoroscopy, thus exposing patients to ionising radiation. The feasibility and safety of non-fluoroscopic radiofrequency catheter ablation has been recently reported in a wide range of supraventricular tachyarrhythmias using the EnSite NavX™ mapping system. The NO-PARTY is a multi-centre, randomised controlled trial designed to test the hypothesis that catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system results in a clinically significant reduction in exposure to ionising radiation compared with conventional catheter ablation. The study will randomise 210 patients undergoing catheter ablation of supraventricular tachyarrhythmias to either a conventional ablation technique or one guided by the EnSite NavX™ mapping system. The primary end-point is the reduction of the radiation dose to the patient. Secondary end-points include procedural success, reduction of the radiation dose to the operator, and a cost-effectiveness analysis. In a subgroup of patients, we will also evaluate the radiobiological effectiveness of dose reduction by assessing acute chromosomal DNA damage in peripheral blood lymphocytes. NO-PARTY will determine whether radiofrequency catheter ablation of supraventricular tachyarrhythmias guided by the EnSite NavX™ mapping system is a suitable and cost-effective approach to achieve a clinically significant reduction in ionising radiation exposure for both patient and operator.

  18. Shoulder, hip, and knee arthrography needle placement using fluoroscopic guidance: practice patterns of musculoskeletal radiologists in North America

    International Nuclear Information System (INIS)

    Shortt, Conor P.; Morrison, William B.; Deely, Diane M.; Gopez, Angela G.; Zoga, Adam C.; Roberts, Catherine C.

    2009-01-01

    The aim of this study was to evaluate the range of techniques used by radiologists performing shoulder, hip, and knee arthrography using fluoroscopic guidance. Questionnaires on shoulder, hip, and knee arthrography were distributed to radiologists at a national radiology meeting. We enquired regarding years of experience, preferred approaches, needle gauge, gadolinium dilution, and volume injected. For each approach, the radiologist was asked their starting and end needle position based on a numbered and lettered grid superimposed on a radiograph. Sixty-eight questionnaires were returned. Sixty-eight radiologists performed shoulder and hip arthrography, and 65 performed knee arthrograms. Mean experience was 13.5 and 12.8 years, respectively. For magnetic resonance arthrography, a gadolinium dilution of 1/200 was used by 69-71%. For shoulder arthrography, an anterior approach was preferred by 65/68 (96%). The most common site of needle end position, for anterior and posterior approaches, was immediately lateral to the humeral cortex. A 22-gauge needle was used by 46/66 (70%). Mean injected volume was 12.7 ml (5-30). For hip arthrography, an anterior approach was preferred by 51/68 (75%). The most common site of needle end position, for anterior and lateral approaches, was along the lateral femoral head/neck junction. A 22-gauge needle was used by 53/68 (78%). Mean injected volume was 11.5 ml (5-20). For knee arthrography, a lateral approach was preferred by 41/64 (64%). The most common site of needle end position, for lateral and medial approaches, was mid-patellofemoral joint level. A 22-gauge needle was used by 36/65 (56%). Mean injected volume was 28.2 ml (5-60). Arthrographic approaches for the shoulder, hip, and knee vary among radiologists over a wide range of experience levels. (orig.)

  19. Shoulder, hip, and knee arthrography needle placement using fluoroscopic guidance: practice patterns of musculoskeletal radiologists in North America

    Energy Technology Data Exchange (ETDEWEB)

    Shortt, Conor P. [Thomas Jefferson University Hospital, Department of Radiology, Philadelphia, PA (United States); Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, PA (United States); Morrison, William B.; Deely, Diane M.; Gopez, Angela G.; Zoga, Adam C. [Thomas Jefferson University Hospital, Department of Radiology, Philadelphia, PA (United States); Roberts, Catherine C. [Mayo Clinic College of Medicine, Department of Radiology, Phoenix, AZ (United States)

    2009-04-15

    The aim of this study was to evaluate the range of techniques used by radiologists performing shoulder, hip, and knee arthrography using fluoroscopic guidance. Questionnaires on shoulder, hip, and knee arthrography were distributed to radiologists at a national radiology meeting. We enquired regarding years of experience, preferred approaches, needle gauge, gadolinium dilution, and volume injected. For each approach, the radiologist was asked their starting and end needle position based on a numbered and lettered grid superimposed on a radiograph. Sixty-eight questionnaires were returned. Sixty-eight radiologists performed shoulder and hip arthrography, and 65 performed knee arthrograms. Mean experience was 13.5 and 12.8 years, respectively. For magnetic resonance arthrography, a gadolinium dilution of 1/200 was used by 69-71%. For shoulder arthrography, an anterior approach was preferred by 65/68 (96%). The most common site of needle end position, for anterior and posterior approaches, was immediately lateral to the humeral cortex. A 22-gauge needle was used by 46/66 (70%). Mean injected volume was 12.7 ml (5-30). For hip arthrography, an anterior approach was preferred by 51/68 (75%). The most common site of needle end position, for anterior and lateral approaches, was along the lateral femoral head/neck junction. A 22-gauge needle was used by 53/68 (78%). Mean injected volume was 11.5 ml (5-20). For knee arthrography, a lateral approach was preferred by 41/64 (64%). The most common site of needle end position, for lateral and medial approaches, was mid-patellofemoral joint level. A 22-gauge needle was used by 36/65 (56%). Mean injected volume was 28.2 ml (5-60). Arthrographic approaches for the shoulder, hip, and knee vary among radiologists over a wide range of experience levels. (orig.)

  20. Percutaneous radiologic gastrostomy versus percutaneous endoscopic gastrostomy: A comparison of indications, complications and outcomes in 370 patients

    International Nuclear Information System (INIS)

    Silas, Anne M.; Pearce, Lindsay F.; Lestina, Lisa S.; Grove, Margaret R.; Tosteson, Anna; Manganiello, Wendy D.; Bettmann, Michael A.; Gordon, Stuart R.

    2005-01-01

    Objective: Percutaneous access to the stomach can be achieved by endoscopic or fluoroscopic methods. Our objective was to compare indications, complications, efficacy and outcomes of these two techniques. Methods: Records of 370 patients with feeding tubes placed either endoscopically by gastroenterology, or fluoroscopically by radiology, at our university-based tertiary care center over a 54-month period were reviewed. Results: 177 gastrostomies were placed endoscopically and 193 fluoroscopically. Nutrition was the most common indication in each group (94 and 92%), but the most common underlying diagnosis was neurologic impairment in the endoscopic group (n = 89, 50%) and malignancy in the fluoroscopic group (n = 134, 69%) (p < 0.001). Complications in the first 30 days were more common with fluoroscopic placement (23% versus 11%, p = 0.002), with infection most frequent. Correlates of late complications were inpatient status (OR 0.26, 95%CI: 0.13-0.51) and a diagnosis of malignancy (OR 2.2, 95%CI: 1.03-4.84). Average follow-up time was 108 days in the fluoroscopic group and 174 days in the endoscopic group. Conclusions: Both endoscopic and fluoroscopic gastrostomy tube placement are safe and effective. Outpatient status was associated with greater early and late complication rates; minor complications such as infection were greater in the fluoroscopic group, while malignancy was associated with late complications

  1. SU-E-CAMPUS-I-04: Automatic Skin-Dose Mapping for An Angiographic System with a Region-Of-Interest, High-Resolution Detector

    Energy Technology Data Exchange (ETDEWEB)

    Vijayan, S; Rana, V [Department of Physiology and Biophysics, Toshiba Stroke and Vascular Research Center (United States); Setlur Nagesh, S [Toshiba Stroke and Vascular Research Center (United States); Ionita, C [Department of Biomedical Engineering, University at Buffalo (State University of New York), Buffalo, NY (United States); Rudin, S [Department of Radiology, Department of Physiology and Biophysics, Toshiba Stroke and Vascular Research Center, Department of Biomedical Engineering, University at Buffalo (State University of New York), Buffalo, NY (United States); Bednarek, D [Department of Radiology, Department of Physiology and Biophysics, Toshiba Stroke and Vascular Research Center (United States)

    2014-06-15

    Purpose: Our real-time skin dose tracking system (DTS) has been upgraded to monitor dose for the micro-angiographic fluoroscope (MAF), a high-resolution, small field-of-view x-ray detector. Methods: The MAF has been mounted on a changer on a clinical C-Arm gantry so it can be used interchangeably with the standard flat-panel detector (FPD) during neuro-interventional procedures when high resolution is needed in a region-of-interest. To monitor patient skin dose when using the MAF, our DTS has been modified to automatically account for the change in scatter for the very small MAF FOV and to provide separated dose distributions for each detector. The DTS is able to provide a color-coded mapping of the cumulative skin dose on a 3D graphic model of the patient. To determine the correct entrance skin exposure to be applied by the DTS, a correction factor was determined by measuring the exposure at the entrance surface of a skull phantom with an ionization chamber as a function of entrance beam size for various beam filters and kVps. Entrance exposure measurements included primary radiation, patient backscatter and table forward scatter. To allow separation of the dose from each detector, a parameter log is kept that allows a replay of the procedure exposure events and recalculation of the dose components.The graphic display can then be constructed showing the dose distribution from the MAF and FPD separately or together. Results: The DTS is able to provide separate displays of dose for the MAF and FPD with field-size specific scatter corrections. These measured corrections change from about 49% down to 10% when changing from the FPD to the MAF. Conclusion: The upgraded DTS allows identification of the patient skin dose delivered when using each detector in order to achieve improved dose management as well as to facilitate peak skin-dose reduction through dose spreading. Research supported in part by Toshiba Medical Systems Corporation and NIH Grants R43FD0158401, R44FD

  2. TU-FG-209-05: Demonstration of the Line Focus Principle Using the Generalized Measured-Relative Object Detectability (GM-ROD) Metric

    Energy Technology Data Exchange (ETDEWEB)

    Russ, M; Shankar, A; Lau, A; Bednarek, D; Rudin, S [University at Buffalo (SUNY), Buffalo, NY (United States)

    2016-06-15

    Purpose: Demonstrate and quantify the augmented resolution due to focalspot size decrease in images acquired on the anode side of the field, for both small and medium (0.3 and 0.6mm) focal-spot sizes using the experimental task-based GM-ROD metric. Theoretical calculations have shown that a medium focal-spot can achieve the resolution of a small focal-spot if acquired with a tilted anode, effectively providing a higher-output small focal-spot. Methods: The MAF-CMOS (micro-angiographic fluoroscopic complementary-metal-oxide semiconductor) detector (75µm pixel pitch) imaged two copper wire segments of different diameter and a pipeline stent at the central axis and on the anode side of the beam, achieved by tilting the x-ray C-arm (Toshiba Infinix) to 6° and realigning the detector with the perpendicular ray to correct for x-ray obliquity. The relative gain in resolution was determined using the GM-ROD metric, which compares images on the basis of the Fourier transform of the image and the measured NNPS. To emphasize the geometric unsharpness, images were acquired at a magnification of two. Results: Images acquired on the anode side were compared to those acquired on the central axis with the same target-area focal-spot to consider the effect of an angled tube, and for all three objects the advantage of the smaller effective focal-spot was clear, showing a maximum improvement of 36% in GM-ROD. The images obtained with the small focal-spot at the central axis were compared to those of the medium focal-spot at the anode side and, for all objects, the relative performance was comparable. Conclusion: For three objects, the GM-ROD demonstrated the advantage of the anode side focal-spot. The comparable performance of the medium focal-spot on the anode side will allow for a high-output small focal-spot; a necessity in endovascular image-guided interventions. Partial support from an NIH grant R01EB002873 and an equipment grant from Toshiba Medical Systems Corp.

  3. TU-FG-209-05: Demonstration of the Line Focus Principle Using the Generalized Measured-Relative Object Detectability (GM-ROD) Metric

    International Nuclear Information System (INIS)

    Russ, M; Shankar, A; Lau, A; Bednarek, D; Rudin, S

    2016-01-01

    Purpose: Demonstrate and quantify the augmented resolution due to focalspot size decrease in images acquired on the anode side of the field, for both small and medium (0.3 and 0.6mm) focal-spot sizes using the experimental task-based GM-ROD metric. Theoretical calculations have shown that a medium focal-spot can achieve the resolution of a small focal-spot if acquired with a tilted anode, effectively providing a higher-output small focal-spot. Methods: The MAF-CMOS (micro-angiographic fluoroscopic complementary-metal-oxide semiconductor) detector (75µm pixel pitch) imaged two copper wire segments of different diameter and a pipeline stent at the central axis and on the anode side of the beam, achieved by tilting the x-ray C-arm (Toshiba Infinix) to 6° and realigning the detector with the perpendicular ray to correct for x-ray obliquity. The relative gain in resolution was determined using the GM-ROD metric, which compares images on the basis of the Fourier transform of the image and the measured NNPS. To emphasize the geometric unsharpness, images were acquired at a magnification of two. Results: Images acquired on the anode side were compared to those acquired on the central axis with the same target-area focal-spot to consider the effect of an angled tube, and for all three objects the advantage of the smaller effective focal-spot was clear, showing a maximum improvement of 36% in GM-ROD. The images obtained with the small focal-spot at the central axis were compared to those of the medium focal-spot at the anode side and, for all objects, the relative performance was comparable. Conclusion: For three objects, the GM-ROD demonstrated the advantage of the anode side focal-spot. The comparable performance of the medium focal-spot on the anode side will allow for a high-output small focal-spot; a necessity in endovascular image-guided interventions. Partial support from an NIH grant R01EB002873 and an equipment grant from Toshiba Medical Systems Corp.

  4. MO-F-CAMPUS-I-01: A System for Automatically Calculating Organ and Effective Dose for Fluoroscopically-Guided Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Xiong, Z; Vijayan, S; Rana, V; Rudin, S; Bednarek, D [Toshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY (United States)

    2015-06-15

    Purpose: A system was developed that automatically calculates the organ and effective dose for individual fluoroscopically-guided procedures using a log of the clinical exposure parameters. Methods: We have previously developed a dose tracking system (DTS) to provide a real-time color-coded 3D- mapping of skin dose. This software produces a log file of all geometry and exposure parameters for every x-ray pulse during a procedure. The data in the log files is input into PCXMC, a Monte Carlo program that calculates organ and effective dose for projections and exposure parameters set by the user. We developed a MATLAB program to read data from the log files produced by the DTS and to automatically generate the definition files in the format used by PCXMC. The processing is done at the end of a procedure after all exposures are completed. Since there are thousands of exposure pulses with various parameters for fluoroscopy, DA and DSA and at various projections, the data for exposures with similar parameters is grouped prior to entry into PCXMC to reduce the number of Monte Carlo calculations that need to be performed. Results: The software developed automatically transfers data from the DTS log file to PCXMC and runs the program for each grouping of exposure pulses. When the dose from all exposure events are calculated, the doses for each organ and all effective doses are summed to obtain procedure totals. For a complicated interventional procedure, the calculations can be completed on a PC without manual intervention in less than 30 minutes depending on the level of data grouping. Conclusion: This system allows organ dose to be calculated for individual procedures for every patient without tedious calculations or data entry so that estimates of stochastic risk can be obtained in addition to the deterministic risk estimate provided by the DTS. Partial support from NIH grant R01EB002873 and Toshiba Medical Systems Corp.

  5. The accuracy and safety of fluoroscopically guided percutaneous pedicle screws in the lumbosacral junction and the lumbar spine: a review of 880 screws.

    Science.gov (United States)

    Chiu, C K; Kwan, M K; Chan, C Y W; Schaefer, C; Hansen-Algenstaedt, N

    2015-08-01

    We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location. ©2015 The British Editorial Society of Bone & Joint Surgery.

  6. Experimental osteoarthritis in the rabbit knee joint

    International Nuclear Information System (INIS)

    Bohr, H.

    1976-01-01

    development of arthrotic-like changes following resection of the of the cruciate ligaments in the knee joint of rabbits has been studied at intervals from 2 weeks to 10 months in 35 animals. Signs of cartilage degeneration were followed by changes in the subchondral bone, where formation of osteophytes and condensation to took place. An increased vascular supply was demonstrated by microangiographic and scintigraphic investigations. The uptake of 18 F and 99 mTc-polyphosphate reached a maximal value about 2 months after the operation and then diminished despite further development of arthrotic changes. (author)

  7. SU-C-210-04: Considerable Pancreatic Tumor Motion During Breath-Hold Measured Using Intratumoral Fiducials On Fluoroscopic Movies

    Energy Technology Data Exchange (ETDEWEB)

    Lens, E; Horst, A van der; Versteijne, E; Tienhoven, G van; Bel, A [Academic Medical Center, Amsterdam (Netherlands)

    2015-06-15

    Purpose: Using a breath hold (BH) technique during radiotherapy of pancreatic tumors is expected to reduce intra-fractional motion. The aim of this study was to evaluate the tumor motion during BH. Methods: In this pilot study, we included 8 consecutive pancreatic cancer patients. All had 2– 4 intratumoral gold fiducials. Patients were asked to perform 3 consecutive 30-second end-inhale BHs on day 5, 10 and 15 of their three-week treatment. During BH, airflow through a mouthpiece was measured using a spirometer. Any inadvertent flow of air during BH was monitored for all patients. We measured tumor motion on lateral fluoroscopic movies (57 in total) made during BH. In each movie the fiducials as a group were tracked over time in superior-inferior (SI) and anterior-posterior (AP) direction using 2-D image correlation between consecutive frames. We determined for each patient the range of intra-BH motion over all movies; we also determined the absolute means and standard deviations (SDs) for the entire patient group. Additionally, we investigated the relation between inadvertent airflow during BH and the intra-BH motion. Results: We found intra-BH tumor motion of up to 12.5 mm (range, 1.0–12.5 mm) in SI direction and up to 8.0 mm (range, 1.0–8.0 mm) in AP direction. The absolute mean motion over the patient population was 4.7 (SD: 3.0) mm and 2.8 (SD: 1.2) mm in the SI and AP direction, respectively. Patients were able to perform stable consecutive BHs; during only 20% of the movies we found very small airflows (≤ 65 ml). These were mostly stepwise in nature and could not explain the continuous tumor motions we observed. Conclusion: We found substantial (up to 12.5 mm) pancreatic tumor motion during BHs. We found minimal inadvertent airflow, seen only during a minority of BHs, and this did not explain the obtained results. This work was supported by the foundation Bergh in het Zadel through the Dutch Cancer Society (KWF Kankerbestrijding) project No. UVA 2011-5271.

  8. A study of the x-ray image quality improvement in the examination of the respiratory system based on the new image processing technique

    Science.gov (United States)

    Nagai, Yuichi; Kitagawa, Mayumi; Torii, Jun; Iwase, Takumi; Aso, Tomohiko; Ihara, Kanyu; Fujikawa, Mari; Takeuchi, Yumiko; Suzuki, Katsumi; Ishiguro, Takashi; Hara, Akio

    2014-03-01

    Recently, the double contrast technique in a gastrointestinal examination and the transbronchial lung biopsy in an examination for the respiratory system [1-3] have made a remarkable progress. Especially in the transbronchial lung biopsy, better quality of x-ray fluoroscopic images is requested because this examination is performed under a guidance of x-ray fluoroscopic images. On the other hand, various image processing methods [4] for x-ray fluoroscopic images have been developed as an x-ray system with a flat panel detector [5-7] is widely used. A recursive filtering is an effective method to reduce a random noise in x-ray fluoroscopic images. However it has a limitation for its effectiveness of a noise reduction in case of a moving object exists in x-ray fluoroscopic images because the recursive filtering is a noise reduction method by adding last few images. After recursive filtering a residual signal was produced if a moving object existed in x-ray images, and this residual signal disturbed a smooth procedure of the examinations. To improve this situation, new noise reduction method has been developed. The Adaptive Noise Reduction [ANR] is the brand-new noise reduction technique which can be reduced only a noise regardless of the moving object in x-ray fluoroscopic images. Therefore the ANR is a very suitable noise reduction method for the transbronchial lung biopsy under a guidance of x-ray fluoroscopic images because the residual signal caused of the moving object in x-ray fluoroscopic images is never produced after the ANR. In this paper, we will explain an advantage of the ANR by comparing of a performance between the ANR images and the conventional recursive filtering images.

  9. Patient Dose Optimization in Fluoroscopically Guided Interventional Procedures. Final Report of a Coordinated Research Project

    International Nuclear Information System (INIS)

    2010-01-01

    In recent years, many surgical procedures have increasingly been replaced by interventional procedures that guide catheters into the arteries under X ray fluoroscopic guidance to perform a variety of operations such as ballooning, embolization, implantation of stents etc. The radiation exposure to patients and staff in such procedures is much higher than in simple radiographic examinations like X ray of chest or abdomen such that radiation induced skin injuries to patients and eye lens opacities among workers have been reported in the 1990's and after. Interventional procedures have grown both in frequency and importance during the last decade. This Coordinated Research Project (CRP) and TECDOC were developed within the International Atomic Energy Agency's (IAEA) framework of statutory responsibility to provide for the worldwide application of the standards for the protection of people against exposure to ionizing radiation. The CRP took place between 2003 and 2005 in six countries, with a view of optimizing the radiation protection of patients undergoing interventional procedures. The Fundamental Safety Principles and the International Basic Safety Standards for Protection against Ionizing Radiation (BSS) issued by the IAEA and co-sponsored by the Food and Agriculture Organization of the United Nations (FAO), the International Labour Organization (ILO), the World Health Organization (WHO), the Pan American Health Organization (PAHO) and the Nuclear Energy Agency (NEA), among others, require the radiation protection of patients undergoing medical exposures through justification of the procedures involved and through optimization. In keeping with its responsibility on the application of standards, the IAEA programme on Radiological Protection of Patients encourages the reduction of patient doses. To facilitate this, it has issued specific advice on the application of the BSS in the field of radiology in Safety Reports Series No. 39 and the three volumes on Radiation

  10. Comparison of respiratory surrogates for gated lung radiotherapy without internal fiducials

    International Nuclear Information System (INIS)

    Korreman, S.; Mostafavi, H.; Le, Q.T.; Boyer, A.

    2006-01-01

    An investigation was carried out to compare the ability of two respiratory surrogates to mimic actual lung tumor motion during audio coaching. The investigation employed video clips acquired after patients had had fiducial markers implanted in lung tumors to be used for image-guided stereoscopic radiotherapy. The positions of the markers in the clips were measured within the video frames and used as the standard for tumor volume motion. An external marker was tracked optically during the fluoroscopic acquisitions. An image correlation technique was developed to compute a gating signal from the fluoroscopic images. The correlation gating trace was similar to the optical gating trace in the phase regions of the respiratory cycle used for gating. A cross correlation analysis and comparison of the external optical marker gating with internal fluoroscopic gating was performed. The fluoroscopic image correlation surrogate was found to be superior to the external optical surrogate in the AP-views in four out of six cases. In one of the remaining two cases, the two surrogates performed comparably, while in the last case, the external fiducial trace performed best. It was concluded that fluoroscopic gating based on correlation of native image features in the fluoroscopic images will be adequate for respiratory gating

  11. Comparison of respiratory surrogates for gated lung radiotherapy without internal fiducials

    Energy Technology Data Exchange (ETDEWEB)

    Korreman, S. [Rigshospitalet, Copenhagen (Denmark). Dept. of Radiation Oncology; Mostafavi, H. [Varian Medical Systems, Mountain View, CA (United States). Gintzon Technology Center; Le, Q.T.; Boyer, A. [Stanford Univ. School of Medicine, CA (United States). Dept. of Radiation Oncology

    2006-09-15

    An investigation was carried out to compare the ability of two respiratory surrogates to mimic actual lung tumor motion during audio coaching. The investigation employed video clips acquired after patients had had fiducial markers implanted in lung tumors to be used for image-guided stereoscopic radiotherapy. The positions of the markers in the clips were measured within the video frames and used as the standard for tumor volume motion. An external marker was tracked optically during the fluoroscopic acquisitions. An image correlation technique was developed to compute a gating signal from the fluoroscopic images. The correlation gating trace was similar to the optical gating trace in the phase regions of the respiratory cycle used for gating. A cross correlation analysis and comparison of the external optical marker gating with internal fluoroscopic gating was performed. The fluoroscopic image correlation surrogate was found to be superior to the external optical surrogate in the AP-views in four out of six cases. In one of the remaining two cases, the two surrogates performed comparably, while in the last case, the external fiducial trace performed best. It was concluded that fluoroscopic gating based on correlation of native image features in the fluoroscopic images will be adequate for respiratory gating.

  12. Investigation on effect of image lag in fluoroscopic images obtained with a dynamic flat-panel detector (FPD) on accuracy of target tracking in radiotherapy

    International Nuclear Information System (INIS)

    Tanaka, Rie; Ichikawa, Katsuhiro; Sanada, Sigeru; Mori, Shinichiro; Dobashi, Suguru; Kumagai, Motoki; Minohara, Shinichi; Kawashima, Hiroki

    2010-01-01

    Real-time tumor tracking in external radiotherapy can be achieved by diagnostic (kV) X-ray imaging with a dynamic flat-panel detector (FPD). The purpose of this study was to address image lag in target tracking and its influence on the accuracy of tumor tracking. Fluoroscopic images were obtained using a direct type of dynamic FPD. Image lag properties were measured without test devices according to IEC 62220-1. Modulation transfer function (MTF) and profile curves were measured on the edges of a moving tungsten plate at movement rate of 10 and 20 mm/s, covering lung tumor movement of normal breathing. A lung tumor and metal sphere with blurred edge due to image lag was simulated using the results and then superimposed on breathing chest radiographs of a patient. The moving target with and without image lag was traced using a template-matching technique. In the results, the image lag for the first frame after X-ray cutoff was 2.0% and decreased to less than 0.1% in the fifth frame. In the measurement of profile curves on the edges of static and moving tungsten material plates, the effect of image lag was seen as blurred edges of the plate. The blurred edges of a moving target were indicated as reduction of MTF. However, the target could be traced within an error of ±5 mm. The results indicated that there was no effect of image lag on target tracking in usual breathing speed in a radiotherapy situation. (author)

  13. Semi-automatic fluoroscope

    International Nuclear Information System (INIS)

    Tarpley, M.W.

    1976-10-01

    Extruded aluminum-clad uranium-aluminum alloy fuel tubes must pass many quality control tests before irradiation in Savannah River Plant nuclear reactors. Nondestructive test equipment has been built to automatically detect high and low density areas in the fuel tubes using x-ray absorption techniques with a video analysis system. The equipment detects areas as small as 0.060-in. dia with 2 percent penetrameter sensitivity. These areas are graded as to size and density by an operator using electronic gages. Video image enhancement techniques permit inspection of ribbed cylindrical tubes and make possible the testing of areas under the ribs. Operation of the testing machine, the special low light level television camera, and analysis and enhancement techniques are discussed

  14. Respiratory-aspirated 35-mm hairpin successfully retrieved with a Teflon® snare system under fluoroscopic guidance via a split endotracheal tube: a useful technique in cases of failed extraction by bronchoscopy and avoiding the need for a thoracotomy.

    Science.gov (United States)

    Gill, S S; Pease, R A; Ashwin, C J; Gill, S S; Tait, N P

    2012-09-01

    Respiratory foreign body aspiration (FBA) is a common global health problem requiring prompt recognition and early treatment to prevent potentially fatal complications. The majority of FBAs are due to organic objects and treatment is usually via either endoscopic or surgical extraction. FBA of a straight hairpin has been described as a unique entity in the literature, occurring most commonly in females, particularly during adolescence. In the process of inserting hairpins, the pins will typically be between the teeth with the head tilted backwards, while tying their hair with both hands. This position increases the risk of aspiration, particularly if there is any sudden coughing or laughing. To our knowledge, this is the first case report of a 35-mm straight metallic hairpin foreign body that has been successfully retrieved by a radiological snare system under fluoroscopic guidance. This was achieved with the use of a split endotracheal tube, and therefore avoided the need for a thoracotomy in an adolescent female patient.

  15. Video x-ray progressive scanning: new technique for decreasing x-ray exposure without decreasing image quality during cardiac catheterization

    International Nuclear Information System (INIS)

    Holmes, D.R. Jr.; Bove, A.A.; Wondrow, M.A.; Gray, J.E.

    1986-01-01

    A newly developed video x-ray progressive scanning system improves image quality, decreases radiation exposure, and can be added to any pulsed fluoroscopic x-ray system using a video display without major system modifications. With use of progressive video scanning, the radiation entrance exposure rate measured with a vascular phantom was decreased by 32 to 53% in comparison with a conventional fluoroscopic x-ray system. In addition to this substantial decrease in radiation exposure, the quality of the image was improved because of less motion blur and artifact. Progressive video scanning has the potential for widespread application to all pulsed fluoroscopic x-ray systems. Use of this technique should make cardiac catheterization procedures and all other fluoroscopic procedures safer for the patient and the involved medical and paramedical staff

  16. Risk of whole body radiation exposure and protective measures in fluoroscopically guided interventional techniques: a prospective evaluation

    Directory of Open Access Journals (Sweden)

    Rivera Jose

    2003-08-01

    Full Text Available Abstract Background Fluoroscopic guidance is frequently utilized in interventional pain management. The major purpose of fluoroscopy is correct needle placement to ensure target specificity and accurate delivery of the injectate. Radiation exposure may be associated with risks to physician, patient and personnel. While there have been many studies evaluating the risk of radiation exposure and techniques to reduce this risk in the upper part of the body, the literature is scant in evaluating the risk of radiation exposure in the lower part of the body. Methods Radiation exposure risk to the physician was evaluated in 1156 patients undergoing interventional procedures under fluoroscopy by 3 physicians. Monitoring of scattered radiation exposure in the upper and lower body, inside and outside the lead apron was carried out. Results The average exposure per procedure was 12.0 ± 9.8 seconds, 9.0 ± 0.37 seconds, and 7.5 ± 1.27 seconds in Groups I, II, and III respectively. Scatter radiation exposure ranged from a low of 3.7 ± 0.29 seconds for caudal/interlaminar epidurals to 61.0 ± 9.0 seconds for discography. Inside the apron, over the thyroid collar on the neck, the scatter radiation exposure was 68 mREM in Group I consisting of 201 patients who had a total of 330 procedures with an average of 0.2060 mREM per procedure and 25 mREM in Group II consisting of 446 patients who had a total of 662 procedures with average of 0.0378 mREM per procedure. The scatter radiation exposure was 0 mREM in Group III consisting of 509 patients who had a total 827 procedures. Increased levels of exposures were observed in Groups I and II compared to Group III, and Group I compared to Group II. Groin exposure showed 0 mREM exposure in Groups I and II and 15 mREM in Group III. Scatter radiation exposure for groin outside the apron in Group I was 1260 mREM and per procedure was 3.8182 mREM. In Group II the scatter radiation exposure was 400 mREM and with 0.6042 m

  17. Revascularization of autogenous skin grafts placed on irradiated tissue

    International Nuclear Information System (INIS)

    Ueda, M.; Torii, S.; Kaneda, T.; Oka, T.

    1982-01-01

    Vascular changes in rat skin after irradiation were examined microangiographically. Revascularization of the skin transplanted during the chronic stage after irradiation was also studied. The results obtained through these examinations revealed higher vascular densities at the acute and the subacute stages, and low values at the chronic stages compared with those of the control. Furthermore, when the skin grafts were transplanted to the irradiated beds in the chronic stage, primary revascularization was scant, and the inhibited capillary proliferation in the recipient sites prevented new vessel penetration. This explains why grafts transplanted to previously irradiated beds fail to survive

  18. Deep sedation during pneumatic reduction of intussusception.

    Science.gov (United States)

    Ilivitzki, Anat; Shtark, Luda Glozman; Arish, Karin; Engel, Ahuva

    2012-05-01

    Pneumatic reduction of intussusception under fluoroscopic guidance is a routine procedure. The unsedated child may resist the procedure, which may lengthen its duration and increase the radiation dose. We use deep sedation during the procedure to overcome these difficulties. The purpose of this study was to summarize our experience with deep sedation during fluoroscopic reduction of intussusception and assess the added value and complication rate of deep sedation. All children with intussusception who underwent pneumatic reduction in our hospital between January 2004 and June 2011 were included in this retrospective study. Anesthetists sedated the children using propofol. The fluoroscopic studies, ultrasound (US) studies and the childrens' charts were reviewed. One hundred thirty-one attempted reductions were performed in 119 children, of which 121 (92%) were successful and 10 (8%) failed. Two perforations (1.5%) occurred during attempted reduction. Average fluoroscopic time was 1.5 minutes. No complication to sedation was recorded. Deep sedation with propofol did not add any complication to the pneumatic reduction. The fluoroscopic time was short. The success rate of reduction was high,raising the possibility that sedation is beneficial, possibly by smooth muscle relaxation.

  19. Medical imaging using ionizing radiation: Optimization of dose and image quality in fluoroscopy

    International Nuclear Information System (INIS)

    Jones, A. Kyle; Balter, Stephen; Rauch, Phillip; Wagner, Louis K.

    2014-01-01

    The 2012 Summer School of the American Association of Physicists in Medicine (AAPM) focused on optimization of the use of ionizing radiation in medical imaging. Day 2 of the Summer School was devoted to fluoroscopy and interventional radiology and featured seven lectures. These lectures have been distilled into a single review paper covering equipment specification and siting, equipment acceptance testing and quality control, fluoroscope configuration, radiation effects, dose estimation and measurement, and principles of flat panel computed tomography. This review focuses on modern fluoroscopic equipment and is comprised in large part of information not found in textbooks on the subject. While this review does discuss technical aspects of modern fluoroscopic equipment, it focuses mainly on the clinical use and support of such equipment, from initial installation through estimation of patient dose and management of radiation effects. This review will be of interest to those learning about fluoroscopy, to those wishing to update their knowledge of modern fluoroscopic equipment, to those wishing to deepen their knowledge of particular topics, such as flat panel computed tomography, and to those who support fluoroscopic equipment in the clinic

  20. Transnasal tracheobronchial stenting for malignant airway narrowing under local anesthesia: Our experience of treating three cases using this technique

    International Nuclear Information System (INIS)

    Medhi, Jayanta; Handique, Akash; Goyal, Amit; Lynser, Donbok; Phukan, Pranjal; Sarma, Kalyan; Padmanabhan, Aswin; Saikia, Manuj Kumar; Chutia, Happy

    2016-01-01

    To study the technical feasibility of tracheobronchial stenting via transnasal route under bronchoscopy and fluoroscopic guidance in severe malignant airway strictures using self-expandable nitinol stents. We describe three patients with malignant airway strictures, treated entirely via transnasal route under local anesthesia using bronchoscopic and fluoroscopic guidance. Nasal route allowed convenient access to the airway for the bronchoscope across the stricture and a guidewire was introduced through its working channel. The 18F tracheal stent and the 6F bronchial stent assembly could be easily introduced and deployed under bronchoscopic (reintroduced through the other nostril) and fluoroscopic guidance. We achieved technical success in all the three patients with immediate relief of dyspnea. Transnasal airway stenting with self-expandable nitinol stent using bronchoscopic and fluoroscopic guidance under local anesthesia is a safe and effective method with minimal patient discomfort

  1. SU-D-204-05: Quantitative Comparison of a High Resolution Micro-Angiographic Fluoroscopic (MAF) Detector with a Standard Flat Panel Detector (FPD) Using the New Metric of Generalized Measured Relative Object Detectability (GM-ROD)

    Energy Technology Data Exchange (ETDEWEB)

    Russ, M; Ionita, C; Bednarek, D; Rudin, S [Toshiba Stroke and Vascular Research Center, University at Buffalo (SUNY), Buffalo, NY (United States)

    2015-06-15

    Purpose: In endovascular image-guided neuro-interventions, visualization of fine detail is paramount. For example, the ability of the interventionist to visualize the stent struts depends heavily on the x-ray imaging detector performance. Methods: A study to examine the relative performance of the high resolution MAF-CMOS (pixel size 75µm, Nyquist frequency 6.6 cycles/mm) and a standard Flat Panel Detector (pixel size 194µm, Nyquist frequency 2.5 cycles/mm) detectors in imaging a neuro stent was done using the Generalized Measured Relative Object Detectability (GM-ROD) metric. Low quantum noise images of a deployed stent were obtained by averaging 95 frames obtained by both detectors without changing other exposure or geometric parameters. The square of the Fourier transform of each image is taken and divided by the generalized normalized noise power spectrum to give an effective measured task-specific signal-to-noise ratio. This expression is then integrated from 0 to each of the detector’s Nyquist frequencies, and the GM-ROD value is determined by taking a ratio of the integrals for the MAF-CMOS to that of the FPD. The lower bound of integration can be varied to emphasize high frequencies in the detector comparisons. Results: The MAF-CMOS detector exhibits vastly superior performance over the FPD when integrating over all frequencies, yielding a GM-ROD value of 63.1. The lower bound of integration was stepped up in increments of 0.5 cycles/mm for higher frequency comparisons. As the lower bound increased, the GM-ROD value was augmented, reflecting the superior performance of the MAF-CMOS in the high frequency regime. Conclusion: GM-ROD is a versatile metric that can provide quantitative detector and task dependent comparisons that can be used as a basis for detector selection. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

  2. Transnasal tracheobronchial stenting for malignant airway narrowing under local anesthesia: Our experience of treating three cases using this technique

    Directory of Open Access Journals (Sweden)

    Jayanta Medhi

    2016-01-01

    Full Text Available Purpose: To study the technical feasibility of tracheobronchial stenting via transnasal route under bronchoscopy and fluoroscopic guidance in severe malignant airway strictures using self-expandable nitinol stents. Materials and Methods: We describe three patients with malignant airway strictures, treated entirely via transnasal route under local anesthesia using bronchoscopic and fluoroscopic guidance. Nasal route allowed convenient access to the airway for the bronchoscope across the stricture and a guidewire was introduced through its working channel. The 18F tracheal stent and the 6F bronchial stent assembly could be easily introduced and deployed under bronchoscopic (reintroduced through the other nostril and fluoroscopic guidance. Results: We achieved technical success in all the three patients with immediate relief of dyspnea. Conclusion: Transnasal airway stenting with self-expandable nitinol stent using bronchoscopic and fluoroscopic guidance under local anesthesia is a safe and effective method with minimal patient discomfort.

  3. Radiologic Analysis and Clinical Study of the Upper One-third Joint Technique for Fluoroscopically Guided Sacroiliac Joint Injection.

    Science.gov (United States)

    Park, Junghyun; Park, Hue Jung; Moon, Dong Eon; Sa, Gye Jeol; Kim, Young Hoon

    2015-01-01

    Sacroiliac intraarticular injection by the traditional technique can be challenging to perform when the joint is covered with osteophytes or is extremely narrow. To examine whether there is enough space for the needle to be advanced from the L5-S1 interspinous space to the upper one-third sacroiliac joint (SIJ) by magnetic resonance image (MRI) analysis as an alternative to fluoroscopically guided SIJ injection with the lower one-third joint technique, and to determine the feasibility of this novel technique in clinical practice. MRI analysis and observational study. An interventional pain management practice at a university hospital. We analyzed 200 axial T2-weighted MRIs between the L5 and S1 vertebrae of 100 consecutive patients. The following measurements were obtained on both sides: 1) the thickness of fat in the midline; 2) the distance between the midline (Point C) and the junction (Point A) of the skin and the imaginary line that connects the SIJ and the most medial cortex of the ilium; 3) the distance between the midline (Point C) and the junction (Point B) of the skin and the imaginary line that connects the SIJ and the L5 spinous process; 4) the distance between the SIJ and midline (Point C) on the skin, or between the SIJ and the midpoint (Point C') of the line from Point A to Point B; and 5) the angle between the sagittal line and the imaginary line that connects the SIJ and the midline on the skin. The upper one-third joint technique was performed to establish the feasibility of the alternative technique in 20 patients who had unsuccessful sacroiliac intraarticular injections using the lower one-third joint technique. The mean distances from the midline to Point A and to Point B were 21.9 ± 13.7 mm and 27.8 ± 13.6 mm, respectively. The mean distance between the SIJ and Point C (or Point C') was 81.0 ± 13.3 mm. The angle between the sagittal line and the imaginary line that connects the SIJ and the midline on the skin was 42.8 ± 5.1°. The success

  4. Ultrasound-guided intraarticular injection for MR arthrography of the shoulder; Ultraschallgesteuerte intraartikulaere Kontrastmittelapplikation fuer die MR-Arthrografie der Schulter

    Energy Technology Data Exchange (ETDEWEB)

    Schaeffeler, Christoph; Bruegel, M.; Waldt, S.; Rummeny, E.J.; Woertler, K. [Inst. fuer Roentgendiagnostik, Klinikum rechts der Isar der Technischen Univ. Muenchen (Germany)

    2010-03-15

    Purpose: To evaluate ultrasound guidance for intraarticular contrast injection via an anterolateral approach in comparison with fluoroscopic guidance. Materials and Methods: Contrast agent injection was performed in 40 consecutive patients, 20 under sonographic guidance and 20 under fluoroscopic guidance. None of the patients had previous shoulder surgery. The procedure time was measured and the efficiency of joint distension, incidence of extravasation and intraarticular air on the consecutive MR arthrograms were assessed by three blinded radiologists with musculoskeletal radiology experience. Statistical analysis was performed using the Kruskal-Wallis test. Results: Intraarticular contrast injection was successfully accomplished in all 40 patients. Subsequent MR arthrograms did not show any significant difference between sonographic and fluoroscopic guidance with respect to diagnostic quality, joint distension (p = 0.6665), intraarticular air bubbles (p = 0.1567) and occurrence of contrast extravasation (p = 0.8565). The mean duration of ultrasound-guided injection was 7:30 min compared to a shorter procedure time of 4:15 min for fluoroscopic guidance. In both groups, no procedural complications were observed. Conclusion: Ultrasound-guided injection for MR arthrography of the shoulder via an anterolateral approach represents a simple, safe, and effective technique which yields comparable results to those of injection under fluoroscopic guidance, but is slightly more time-consuming. (orig.)

  5. Ultrasound-guided intraarticular injection for MR arthrography of the shoulder

    International Nuclear Information System (INIS)

    Schaeffeler, Christoph; Bruegel, M.; Waldt, S.; Rummeny, E.J.; Woertler, K.

    2010-01-01

    Purpose: To evaluate ultrasound guidance for intraarticular contrast injection via an anterolateral approach in comparison with fluoroscopic guidance. Materials and Methods: Contrast agent injection was performed in 40 consecutive patients, 20 under sonographic guidance and 20 under fluoroscopic guidance. None of the patients had previous shoulder surgery. The procedure time was measured and the efficiency of joint distension, incidence of extravasation and intraarticular air on the consecutive MR arthrograms were assessed by three blinded radiologists with musculoskeletal radiology experience. Statistical analysis was performed using the Kruskal-Wallis test. Results: Intraarticular contrast injection was successfully accomplished in all 40 patients. Subsequent MR arthrograms did not show any significant difference between sonographic and fluoroscopic guidance with respect to diagnostic quality, joint distension (p = 0.6665), intraarticular air bubbles (p = 0.1567) and occurrence of contrast extravasation (p = 0.8565). The mean duration of ultrasound-guided injection was 7:30 min compared to a shorter procedure time of 4:15 min for fluoroscopic guidance. In both groups, no procedural complications were observed. Conclusion: Ultrasound-guided injection for MR arthrography of the shoulder via an anterolateral approach represents a simple, safe, and effective technique which yields comparable results to those of injection under fluoroscopic guidance, but is slightly more time-consuming. (orig.)

  6. Radiation brain dose to vascular surgeons during fluoroscopically guided interventions is not effectively reduced by wearing lead equivalent surgical caps.

    Science.gov (United States)

    Kirkwood, Melissa L; Arbique, Gary M; Guild, Jeffrey B; Zeng, Katie; Xi, Yin; Rectenwald, John; Anderson, Jon A; Timaran, Carlos

    2018-03-12

    Radiation to the interventionalist's brain during fluoroscopically guided interventions (FGIs) may increase the incidence of cerebral neoplasms. Lead equivalent surgical caps claim to reduce radiation brain doses by 50% to 95%. We sought to determine the efficacy of the RADPAD (Worldwide Innovations & Technologies, Lenexa, Kan) No Brainer surgical cap (0.06 mm lead equivalent at 90 kVp) in reducing radiation dose to the surgeon's and trainee's head during FGIs and to a phantom to determine relative brain dose reductions. Optically stimulated, luminescent nanoDot detectors (Landauer, Glenwood, Ill) inside and outside of the cap at the left temporal position were used to measure cap attenuation during FGIs. To check relative brain doses, nanoDot detectors were placed in 15 positions within an anthropomorphic head phantom (ATOM model 701; CIRS, Norfolk, Va). The phantom was positioned to represent a primary operator performing femoral access. Fluorography was performed on a plastic scatter phantom at 80 kVp for an exposure of 5 Gy reference air kerma with or without the hat. For each brain location, the percentage dose reduction with the hat was calculated. Means and standard errors were calculated using a pooled linear mixed model with repeated measurements. Anatomically similar locations were combined into five groups: upper brain, upper skull, midbrain, eyes, and left temporal position. This was a prospective, single-center study that included 29 endovascular aortic aneurysm procedures. The average procedure reference air kerma was 2.6 Gy. The hat attenuation at the temporal position for the attending physician and fellow was 60% ± 20% and 33% ± 36%, respectively. The equivalent phantom measurements demonstrated an attenuation of 71% ± 2.0% (P < .0001). In the interior phantom locations, attenuation was statistically significant for the skull (6% ± 1.4%) and upper brain (7.2% ± 1.0%; P < .0001) but not for the middle brain (1.4% ± 1.0%; P = .15

  7. Intraoperative three-dimensional fluoroscopy after transpedicular positioning of Kirschner-wire versus conventional intraoperative biplanar fluoroscopic control: A retrospective study of 345 patients and 1880 pedicle screws

    Directory of Open Access Journals (Sweden)

    Ghassan Kerry

    2014-01-01

    Full Text Available Study Design: Retrospective study. Objective: The aim was to find out whether intraoperative three-dimensional imaging after transpedicular positioning of Kirschner wire (K-wire in lumbar and thoracic posterior instrumentation procedures is of benefit to the patients and if this technique is accurately enough to make a postoperative screw position control through computer tomography (CT dispensable. Patients and Methods: Lumbar and thoracic posterior instrumentation procedures conducted at our department between 2002 and 2012 were retrospectively reviewed. The patients were divided into two groups: group A, including patients who underwent intraoperative three-dimensional scan after transpedicular positioning of the K-wire and group B, including patients who underwent only intraoperative biplanar fluoroscopy. An early postoperative CT of the instrumented section was done in all cases to assess the screw position. The rate of immediate intraoperative correction of the K-wires in cases of mal-positioning, as well as the rate of postoperative screw revisions, was measured. Results: In general, 345 patients (1880 screws were reviewed and divided into two groups; group A with 225 patients (1218 screws and group B with 120 patients (662 screws. One patient (0.44% (one screw [0.082%] of group A underwent postoperative screw correction while screw revisions were necessary in 14 patients (11.7% (28 screws [4.2%] of group B. Twenty-three patients (10.2% (28 K-wires [2.3%] of group A underwent intraoperative correction due to primary intraoperative detected K-wire mal-position. None of the corrected K-wires resulted in a corresponding neurological deficit. Conclusion: Three-dimensional imaging after transpedicular K-wire positioning leads to solid intraoperative identification of misplaced K-wires prior to screw placement and reduces screw revision rates compared with conventional fluoroscopic control. When no clinical deterioration emerges, a

  8. Evaluation of the dosimetric performance characteristic of fluoroscopy system used in medicine

    International Nuclear Information System (INIS)

    Qi Xuesong; Wei Kedao; Cheng Yuxi; Zhou Qifu; Ge Lijuan; Hou Changsong

    2001-01-01

    Objective: To discuss establishment of diagnostic reference dose value in fluoroscopic examinations for survey of 16 different types of fluoroscopy systems. Methods: Choosing dosimetric characteristic parameters including: IIESDR, ESDR (typical value) and ESDR max (ESDR maximum), and DAP, which was calibrated in situ on the X-ray unit. Results: Results of dose survey are summarized in three tables, from these we could get wide changes in accordance with those in many other countries resulting from maximum and minimum of IIESDR, ESDR and ESDRmax when measurements were performed at same entrance field size on I.I. Image Intensifier of the 15 fluoroscopy systems and under conditions of ABC. And also we could get less changes of DAP mean values, though differences for patient weight, technological parameters of fluoroscopic exam setting, fluoroscopic time and number of film were more remarkable. Conclusions: Measurements on IIESDR, ESDR (typical value) and ESDRmax (ESDR maximum) are not satisfied as diagnostic reference level. But it is suggested that DAP values, in fluoroscopic exam, are used as a tool to achieve this. (author)

  9. Micro-angiographic investigations of revascularisation of fracture in the canine tibia

    Energy Technology Data Exchange (ETDEWEB)

    Kagel, K.O.; Koecher, W.

    1987-03-01

    Micro-angiograms were performed between eight weeks and one year following osteotomies and pressure osteosyntheses in 34 dog tibiae. Seventeen animals also underwent lumbar sympathectomy. In more than half of the cases, vascularisation of the medulla was reduced by damage to the nutrient artery. Segmental connections could be demonstrated by means of transcortical anastomoses. Following sympathectomy, revascularisation was more marked as a result of numerous trans-osseus anastomoses. This, however, did not lead to improved healing; healing was worse after sympathectomy. Transcortical revascularisation and vessel growth along drill holes are of crucial significance.

  10. Micro-angiographic investigations of revascularisation of fracture in the canine tibia

    International Nuclear Information System (INIS)

    Kagel, K.O.; Koecher, W.; Ernst-Moritz-Arndt-Universitaet, Greifswald

    1987-01-01

    Micro-angiograms were performed between eight weeks and one year following osteotomies and pressure osteosyntheses in 34 dog tibiae. Seventeen animals also underwent lumbar sympathectomy. In more than half of the cases, vascularisation of the medulla was reduced by damage to the nutrient artery. Segmental connections could be demonstrated by means of transcortical anastomoses. Following sympathectomy, revascularisation was more marked as a result of numerous trans-osseus anastomoses. This, however, did not lead to improved healing; healing was worse after sympathectomy. Transcortical revascularisation and vessel growth along drill holes are of crucial significance. (orig.) [de

  11. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations

    Directory of Open Access Journals (Sweden)

    Harman Melinda K

    2012-10-01

    Full Text Available Abstract Background Clinical consequences of alignment errors in total knee replacement (TKR have led to the rigorous evaluation of surgical alignment techniques. Rotational alignment in the transverse plane has proven particularly problematic, with errors due to component malalignment relative to bone anatomic landmarks and an overall mismatch between the femoral and tibial components’ relative positions. Ranges of nominal rotational alignment are not well defined, especially for the tibial component and for relative rotational mismatch, and some studies advocate the use of mobile-bearing TKR to accommodate the resulting small rotation errors. However, the relationships between prosthesis rotational alignment and mobile-bearing polyethylene insert motion are poorly understood. This prospective, in vivo study evaluates whether component malalignment and mismatch affect axial rotation motions during passive knee flexion after TKR. Methods Eighty patients were implanted with mobile-bearing TKR. Rotational alignment of the femoral and tibial components was measured from postoperative CT scans. All TKR were categorized into nominal or outlier groups based on defined norms for surgical rotational alignment relative to bone anatomic landmarks and relative rotational mismatch between the femoral and tibial components. Axial rotation motion of the femoral, tibial and polyethylene bearing components was measured from fluoroscopic images acquired during passive knee flexion. Results Axial rotation motion was generally accomplished in two phases, dominated by polyethylene bearing rotation on the tibial component in early to mid-flexion and then femoral component rotation on the polyethylene articular surface in later flexion. Opposite rotations of the femur-bearing and bearing-baseplate articulations were evident at flexion greater than 80°. Knees with outlier alignment had lower magnitudes of axial rotation and distinct transitions from external to

  12. Fluoroscopically guided transforaminal epidural steroid injections at a quaternary-care teaching institution: effect of trainee involvement and patient body mass index on fluoroscopy time and patient dose

    International Nuclear Information System (INIS)

    Tiegs-Heiden, C.A.; Murthy, N.S.; Geske, J.R.; Diehn, F.E.; Schueler, B.A.; Wald, J.T.; Kaufmann, T.J.; Lehman, V.T.; Carr, C.M.; Amrami, K.K.; Morris, J.M.; Thielen, K.R.; Maus, T.P.

    2016-01-01

    Aim: To investigate whether there are differences in fluoroscopy time and patient dose for fluoroscopically guided lumbar transforaminal epidural steroid injections (TFESIs) performed by staff radiologists versus with trainees and to evaluate the effect of patient body mass index (BMI) on fluoroscopy time and patient dose, including their interactions with other variables. Materials and methods: Single-level lumbar TFESIs (n=1844) between 1 January 2011 and 31 December 2013 were reviewed. Fluoroscopy time, reference point air kerma (K_a_,_r), and kerma area product (KAP) were recorded. BMI and trainee involvement were examined as predictors of fluoroscopy time, K_a_,_r, and KAP in models adjusted for age and gender in multivariable linear models. Stratified models of BMI groups by trainee presence were performed. Results: Increased age was the only significant predictor of increased fluoroscopy time (p<0.0001). K_a_,_r and KAP were significantly higher in patients with a higher BMI (p<0.0001 and p=0.0009). When stratified by BMI, longer fluoroscopy time predicted increased K_a_,_r and KAP in all groups (p<0.0001). Trainee involvement was not a statistically significant predictor of fluoroscopy time or K_a_,_r in any BMI category. KAP was lower with trainees in the overweight group (p=0.0009) and higher in male patients for all BMI categories (p<0.02). Conclusion: Trainee involvement did not result in increased fluoroscopy time or patient dose. BMI did not affect fluoroscopy time; however, overweight and obese patients received significantly higher K_a_,_r and KAP. Male patients received a higher KAP in all BMI categories. Limiting fluoroscopy time and good collimation practices should be reinforced in these patients. - Highlights: • Trainee involvement did not contribute to increased fluoroscopy time or dose. • BMI did not affect fluoroscopy time. • Overweight and obese patients received significantly higher Ka,r and KAP.

  13. SU-G-IeP3-05: Effects of Image Receptor Technology and Dose Reduction Software On Radiation Dose Estimates for Fluoroscopically-Guided Interventional (FGI) Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Merritt, Z; Dave, J; Eschelman, D; Gonsalves, C [Thomas Jefferson University, Philadelphia, PA (United States)

    2016-06-15

    Purpose: To investigate the effects of image receptor technology and dose reduction software on radiation dose estimates for most frequently performed fluoroscopically-guided interventional (FGI) procedures at a tertiary health care center. Methods: IRB approval was obtained for retrospective analysis of FGI procedures performed in the interventional radiology suites between January-2011 and December-2015. This included procedures performed using image-intensifier (II) based systems which were subsequently replaced, flat-panel-detector (FPD) based systems which were later upgraded with ClarityIQ dose reduction software (Philips Healthcare) and relatively new FPD system already equipped with ClarityIQ. Post procedure, technologists entered system-reported cumulative air kerma (CAK) and kerma-area product (KAP; only KAP for II based systems) in RIS; these values were analyzed. Data pre-processing included correcting typographical errors and cross-verifying CAK and KAP. The most frequent high and low dose FGI procedures were identified and corresponding CAK and KAP values were compared. Results: Out of 27,251 procedures within this time period, most frequent high and low dose procedures were chemo/immuno-embolization (n=1967) and abscess drainage (n=1821). Mean KAP for embolization and abscess drainage procedures were 260,657, 310,304 and 94,908 mGycm{sup 2}, and 14,497, 15,040 and 6307 mGycm{sup 2} using II-, FPD- and FPD with ClarityIQ- based systems, respectively. Statistically significant differences were observed in KAP values for embolization procedures with respect to different systems but for abscess drainage procedures significant differences were only noted between systems with FPD and FPD with ClarityIQ (p<0.05). Mean CAK reduced significantly from 823 to 308 mGy and from 43 to 21 mGy for embolization and abscess drainage procedures, respectively, in transitioning to FPD systems with ClarityIQ (p<0.05). Conclusion: While transitioning from II- to FPD- based

  14. A new adjustable parallel drill guide for internal fixation of femoral neck fracture: a developmental and experimental study.

    Science.gov (United States)

    Yuenyongviwat, Varah; Tuntarattanapong, Pakjai; Tangtrakulwanich, Boonsin

    2016-01-11

    Internal fixation is one treatment for femoral neck fracture. Some devices and techniques reported improved accuracy and decreased fluoroscopic time. However, these are not widely used nowadays due to the lack of available special instruments and techniques. To improve the surgical procedure, the authors designed a new adjustable drill guide and tested the efficacy of the device. The authors developed a new adjustable drill guide for cannulated screw guide wire insertion for multiple screw fixation. Eight orthopaedic surgeons performed the experimental study to evaluate the efficacy of this device. Each surgeon performed guide wire insertion for multiple screw fixation in six synthetic femurs: three times with the new device and three times with the conventional technique. The fluoroscopic time, operative time and surgeon satisfaction were evaluated. In the operations with the new adjustable drill guide, the fluoroscopic and operative times were significantly lower than the operations with the conventional technique (p level of satisfaction of this device was also statistically significantly better (p = 0.02) than the conventional technique. The fluoroscopic and operative times with the new adjustable drill guide were reduced for multiple screw fixation of femoral neck fracture and the satisfaction of the surgeons was good.

  15. Rotational micro-CT using a clinical C-arm angiography gantry

    International Nuclear Information System (INIS)

    Patel, V.; Hoffmann, K. R.; Ionita, C. N.; Keleshis, C.; Bednarek, D. R.; Rudin, S.

    2008-01-01

    Rotational angiography (RA) gantries are used routinely to acquire sequences of projection images of patients from which 3D renderings of vascular structures are generated using Feldkamp cone-beam reconstruction algorithms. However, these systems have limited resolution ( 10 lp/mm) but to date have relied either on rotating object imaging or small bore geometry for small animal imaging, and thus are not used for clinical imaging. The authors report here the development and use of a 3D rotational micro-angiography (RMA) system created by mounting a micro-angiographic fluoroscope (MAF) [35 μm pixel, resolution >10 lp/mm, field of view (FOV)=3.6 cm] on a standard clinical FPD-based RA gantry (Infinix, Model RTP12303J-G9E, Toshiba Medical Systems Corp., Tustin, CA). RA image sequences are obtained using the MAF and reconstructed. To eliminate artifacts due to image truncation, lower-dose (compared to MAF acquisition) full-FOV (FFOV) FPD RA sequences (194 μm pixel, FOV=20 cm) were also obtained to complete the missing data. The RA gantry was calibrated using a helical bead phantom. To ensure high-quality high-resolution reconstruction, the high-resolution images from the MAF were aligned spatially with the lower-dose FPD images, and the pixel values in the FPD image data were scaled to match those of the MAF. Images of a rabbit with a coronary stent placed in an artery in the Circle of Willis were obtained and reconstructed. The MAF images appear well aligned with the FPD images (average correlation coefficient before and after alignment: 0.65 and 0.97, respectively) Greater details without any visible truncation artifacts are seen in 3D RMA (MAF-FPD) images than in those of the FPD alone. The FWHM of line profiles of stent struts (100 μm diameter) are approximately 192±21 and 313±38 μm for the 3D RMA and FPD data, respectively. In addition, for the dual-acquisition 3D RMA, FFOV FPD data need not be of the highest quality, and thus may be acquired at lower dose

  16. Psychophysical evaluation of the image quality of a dynamic flat-panel digital x-ray image detector using the threshold contrast detail detectability (TCDD) technique

    Science.gov (United States)

    Davies, Andrew G.; Cowen, Arnold R.; Bruijns, Tom J. C.

    1999-05-01

    We are currently in an era of active development of the digital X-ray imaging detectors that will serve the radiological communities in the new millennium. The rigorous comparative physical evaluations of such devices are therefore becoming increasingly important from both the technical and clinical perspectives. The authors have been actively involved in the evaluation of a clinical demonstration version of a flat-panel dynamic digital X-ray image detector (or FDXD). Results of objective physical evaluation of this device have been presented elsewhere at this conference. The imaging performance of FDXD under radiographic exposure conditions have been previously reported, and in this paper a psychophysical evaluation of the FDXD detector operating under continuous fluoroscopic conditions is presented. The evaluation technique employed was the threshold contrast detail detectability (TCDD) technique, which enables image quality to be measured on devices operating in the clinical environment. This approach addresses image quality in the context of both the image acquisition and display processes, and uses human observers to measure performance. The Leeds test objects TO[10] and TO[10+] were used to obtain comparative measurements of performance on the FDXD and two digital spot fluorography (DSF) systems, one utilizing a Plumbicon camera and the other a state of the art CCD camera. Measurements were taken at a range of detector entrance exposure rates, namely 6, 12, 25 and 50 (mu) R/s. In order to facilitate comparisons between the systems, all fluoroscopic image processing such as noise reduction algorithms, were disabled during the experiments. At the highest dose rate FDXD significantly outperformed the DSF comparison systems in the TCDD comparisons. At 25 and 12 (mu) R/s all three-systems performed in an equivalent manner and at the lowest exposure rate FDXD was inferior to the two DSF systems. At standard fluoroscopic exposures, FDXD performed in an equivalent

  17. Radiation exposure from fluoroscopy during fixation of hip fracture and fracture of ankle: Effect of surgical experience

    Directory of Open Access Journals (Sweden)

    Botchu Rajesh

    2008-01-01

    Full Text Available Background: Over the years, there has been a tremendous increase in the use of fluoroscopy in orthopaedics. The risk of contracting cancer is significantly higher for an orthopedic surgeon. Hip and spine surgeries account for 99% of the total radiation dose. The amount of radiation to patients and operating surgeon depends on the position of the patient and the type of protection used during the surgery. A retrospective study to assess the influence of the radiation exposure of the operating surgeon during fluoroscopically assisted fixation of fractures of neck of femur (dynamic hip screw and ankle (Weber B was performed at a district general hospital in the United Kingdom. Materials and Methods: Sixty patients with undisplaced intertrochanteric fracture were included in the hip group, and 60 patients with isolated fracture of lateral malleolus without communition were included in the ankle group. The hip and ankle groups were further divided into subgroups of 20 patients each depending on the operative experience of the operating surgeon. All patients had fluoroscopically assisted fixation of fracture by the same approach and technique. The radiation dose and screening time of each group were recorded and analyzed. Results: The radiation dose and screening time during fluoroscopically assisted fixation of fracture neck of femur were significantly high with surgeons and trainees with less than 3 years of surgical experience in comparison with surgeons with more than 10 years of experience. The radiation dose and screening time during fluoroscopically assisted fixation of Weber B fracture of ankle were relatively independent of operating surgeon′s surgical experience. Conclusion: The experience of operating surgeon is one of the important factors affecting screening time and radiation dose during fluoroscopically assisted fixation of fracture neck of femur. The use of snapshot pulsed fluoroscopy and involvement of senior surgeons could

  18. Micro-angiography for neuro-vascular imaging. II. Cascade model analysis

    International Nuclear Information System (INIS)

    Ganguly, Arundhuti; Rudin, Stephen; Bednarek, Daniel R.; Hoffmann, Kenneth R.

    2003-01-01

    A micro-angiographic detector was designed and its performance was previously tested to evaluate its feasibility as an improvement over current x-ray detectors for neuro-interventional imaging. The detector was shown to have a modulation transfer function value of about 2% at the Nyquist frequency of 10 cycles/mm and a zero frequency detective quantum efficiency [DQE(0)] value of about 55%. An assessment of the system was required to evaluate whether the current system was performing at its full potential and to determine if any of its components could be optimized to further improve the output. For the purpose, in this study, the parallel cascade theory was used to analyze the performance of the detector under neuro-angiographic conditions by studying the output at the various stages in the imaging chain. A simple model for the spread of light in the CsI(Tl) entrance phosphor was developed and the resolution degradation due to K-fluorescence absorption was calculated. The total gain of the system was found to result in 21 e - (rms) detected at the charge coupled device per absorbed x-ray photon. The gain and the spread of quanta in the imaging chain were used to calculate theoretically the DQE using the parallel cascade model. The results of the model-based calculations matched fairly well with the experimental data previously obtained. This model was then used to optimize the phosphor thickness for the detector. The results showed that the area under the DQE curve had a maximum value at 150 μm of CsI(Tl), though when weighted by the squared signal in frequency space of a 100-μm-diam iodinated vessel, the integral DQE reached a maximum at 250 μm of CsI(Tl). Further, possible locations for gain increase in the imaging chain were determined, and the output of the improved system was simulated. Thus a theoretical analysis for the micro-angiographic detector was performed to better assess its potential

  19. Reduction of CT beam hardening artefacts of ethylene vinyl alcohol copolymer by variation of the tantalum content: evaluation in a standardized aortic endoleak phantom

    International Nuclear Information System (INIS)

    Treitl, Karla M.; Scherr, Michael; Foerth, Monika; Braun, Franziska; Maxien, Daniel; Treitl, Marcus

    2015-01-01

    Our aim was to develop an aortic stent graft phantom to simulate endoleak treatment and to find a tantalum content (TC) of ethylene-vinyl-alcohol-copolymer that causes fewer computed tomography (CT) beam hardening artefacts, but still allows for fluoroscopic visualization. Ethylene-vinyl-alcohol-copolymer specimens of different TC (10-50 %, and 100 %) were injected in an aortic phantom bearing a stent graft and endoleak cavities with simulated re-perfusion. Fluoroscopic visibility of the ethylene-vinyl-alcohol-copolymer specimens was analyzed. In addition, six radiologists analyzed endoleak visibility, and artefact intensity of ethylene-vinyl-alcohol-copolymer in CT. Reduction of TC significantly decreased CT artefact intensity of ethylene-vinyl-alcohol-copolymer and increased visibility of endoleak re-perfusion (p < 0.000). It also significantly decreased fluoroscopic visibility of ethylene-vinyl-alcohol-copolymer (R = 0.883, p ≤ 0.01), and increased the active embolic volumes prior to visualization (Δ ≥ 40 μl). Ethylene-vinyl-alcohol-copolymer specimens with a TC of 45-50 % exhibited reasonable visibility, a low active embolic volume and a tolerable CT artefact intensity. The developed aortic stent graft phantom allows for a reproducible simulation of embolization of endoleaks. The data suggest a reduction of the TC of ethylene-vinyl-alcohol-copolymer to 45 -50 % of the original, to interfere less with diagnostic imaging in follow-up CT examinations, while still allowing for fluoroscopic visualization. (orig.)

  20. ANGIOGRAPHIC ANATOMY OF THE MAJOR ABDOMINAL ARTERIAL BLOOD SUPPLY IN THE DOG.

    Science.gov (United States)

    Culp, William T N; Mayhew, Philipp D; Pascoe, Peter J; Zwingenberger, Allison

    2015-01-01

    Vascular-based interventional radiology (IR) procedures are being more regularly performed in veterinary patients for both diagnostic and therapeutic purposes. A complete description of the fluoroscopic arterial anatomy of the canine abdominal cavity has not been published. This information is essential for performance of IR procedures to allow for improved preparation before and during a particular procedure. The primary purpose of this study was to provide a fluoroscopic description of the vascular branching from the abdominal aorta in a ventro-dorsal projection with a secondary goal of producing pictorial reference images of the major abdominal arterial blood vessels. Five healthy female hound type dogs were enrolled and underwent fluoroscopic arteriography. During fluoroscopy, both nonselective and selective arteriography were performed. The nonselective arteriograms were obtained in the aorta at four locations: cranial to the celiac artery, cranial to the renal arteries, cranial to the caudal mesenteric artery, and cranial to the branching of the external iliac arteries. Selective arteriography was conducted by performing injections into the following arteries: celiac, splenic, common hepatic, cranial mesenteric, left and right renal, and caudal mesenteric. Fluoroscopic arteriography allowed for excellent characterization of the aortic ostia and the location of the lower order vascular branches. Future evaluation of vascular-based treatment options will likely increase as the understanding of the normal and pathologic anatomy improves. © 2015 American College of Veterinary Radiology.

  1. Intraoperative panoramic image using alignment grid, is it accurate?

    Science.gov (United States)

    Apivatthakakul, T; Duanghakrung, M; Luevitoonvechkit, S; Patumasutra, S

    2013-07-01

    Minimally invasive orthopedic trauma surgery relies heavily on intraoperative fluoroscopic images to evaluate the quality of fracture reduction and fixation. However, fluoroscopic images have a narrow field of view and often cannot visualize the entire long bone axis. To compare the coronal femoral alignment between conventional X-rays to that achieved with a new method of acquiring a panoramic intraoperative image. Twenty-four cadaveric femurs with simple diaphyseal fractures were fixed with an angulated broad DCP to create coronal plane malalignment. An intraoperative alignment grid was used to help stitch different fluoroscopic images together to produce a panoramic image. A conventional X-ray of the entire femur was then performed. The coronal plane angulation in the panoramic images was then compared to the conventional X-rays using a Wilcoxon signed rank test. The mean angle measured from the panoramic view was 173.9° (range 169.3°-178.0°) with median of 173.2°. The mean angle measured from the conventional X-ray was 173.4° (range 167.7°-178.7°) with a median angle of 173.5°. There was no significant difference between both methods of measurement (P = 0.48). Panoramic images produced by stitching fluoroscopic images together with help of an alignment grid demonstrated the same accuracy at evaluating the coronal plane alignment of femur fractures as conventional X-rays.

  2. Does Imaging Modality Used For Percutaneous Renal Access Make a Difference?

    DEFF Research Database (Denmark)

    Andonian, Sero; Scoffone, Cesare; Louie, Michael K

    2013-01-01

    OBJECTIVE To assess peri-operative outcomes of percutaneous nephrolithotomy (PCNL) using ultrasound or fluoroscopic guidance for percutaneous access. METHODS A prospectively collected international CROES database containing 5806 patients treated with PCNL was used for the study. Patients were...... divided into two groups based on the methods of percutaneous access: ultrasound vs. fluoroscopy. Patient characteristics, operative data and post-operative outcomes were compared. RESULTS Percutaneous access was obtained using ultrasound guidance only in 453 patients (13.7%) and fluoroscopic guidance only...

  3. Clinical application of self-expandable metallic stents in the treatment of malignant tracheal stenosis under general anesthesia

    International Nuclear Information System (INIS)

    Wang Weitao; Shi Haibin; Yang Zhengqiang; Liu Sheng; Zhou Chungao; Zhao Linbo; Xia Jinguo; Li Linsun

    2009-01-01

    Objective: To evaluate the safety and efficacy of self-expandable metallic stent placement for the treatment of malignant tracheal stenosis under general anesthesia and fluoroscopic guidance. Methods: Under general anesthesia the placement of self-expandable metallic stent was performed in 10 patients with malignant tracheal stenosis, the procedure was completed under fluoroscopic guidance in all patients. Results: Successful tracheal stenting was achieved in all 10 patients. In one patient, a Y-shaped stent was used as the tracheal carina was involved in the airway stenosis. The symptoms of dyspnea and asthma were markedly improved immediately after the implantation of stent in all patients. Conclusion: Tracheal implantation of self-expandable metallic stent under general anesthesia and fluoroscopic guidance is a safe and effective treatment for malignant tracheal stenosis, it can promptly relieve various symptoms caused by malignant tracheal stenosis and obviously improve patient's living quality, therefore,t his technique is of great value in clinical practice. (authors)

  4. Measurement of erosion of stainless steel by molten lead-free solder using micro-focus x-ray CT system

    International Nuclear Information System (INIS)

    Nishikawa, Hiroshi; Takemoto, Tadashi; Kang, Songai

    2009-01-01

    The severe erosion damage, which is caused by a molten lead-free solder, of wave solder equipment made into stainless steel has been encountered in operation. Then, the higher maintenance frequency and reduced life time of wave solder machine component is a serious issue in a manufacturing process. In this study, the evaluation method of erosion of stainless steel by molten lead-free solders was investigated using micro-focus X-ray systems for fluoroscopic and computed tomography (CT). As a result, it was found that the fluoroscopic image could truly reconstruct the cross-shape of the stainless steel sample after immersion test without destruction. In the case of X-ray systems for fluoroscopic and CT used in this study, three-dimensional data can be obtained. Therefore, it was possible to easily check the whole picture of the test sample after immersion test and to decide the maximum erosion depth of test sample. (author)

  5. Dacryocystoplasty

    International Nuclear Information System (INIS)

    Munk, P.L.; Lin, D.T.; Morris, D.C.

    1990-01-01

    Epiphora, or chronic tearing from the eye, is a common problem in ophthalmologic practice and frequently requires surgery for adequate treatment. This paper reports on the development of an interventional radiologic procedure for treatment of this disorder. This technique involves the introduction of a small-bore, soft-tipped guide wire through the superior canaliculis, which is then guided under fluoroscopic control through the nasolacrimal drainage apparatus to be retrieved from the nasal aperature. A small-bore angioplasty catheter is then used for dilation under fluoroscopic control

  6. Wrist arthrography: a simple method

    Energy Technology Data Exchange (ETDEWEB)

    Berna-Serna, Juan D.; Reus, Manuel; Alonso, Jose [Virgen de la Arrixaca University Hospital, Department of Radiology, El Palmar (Murcia) (Spain); Martinez, Francisco; Domenech-Ratto, Gines [University of Murcia, Department of Human Anatomy, Faculty of Medicine, Murcia (Spain)

    2006-02-01

    A technique of wrist arthrography is presented using an adhesive marker-plate with radiopaque coordinates to identify precisely sites for puncture arthrography of the wrist and to obviate the need for fluoroscopic guidance. Radiocarpal joint arthrography was performed successfully in all 24 cases, 14 in the cadaveric wrists and 10 in the live patients. The arthrographic procedure described in this study is simple, safe, and rapid, and has the advantage of precise localisation of the site for puncture without need for fluoroscopic guidance. (orig.)

  7. Problems of dentistrical prophylactic medical examination of persons dealing with ionizing radiation sources

    International Nuclear Information System (INIS)

    Kalinin, V.I.; Ramzaeva, L.V.; Zamanova, L.V.

    1988-01-01

    A comparative study of data of individual dosimetric control of radiological personnel and additional radiation contribution of annual fluoroscopy of chest into radiation load was carried out. It is stated that chest fluoroscopy adds 13 % of collective dose to the occupational irradiation. Efficiency of preventive chest fluoroscopic examination was simultaneously analyzed in 1388 persons engaged in occupational radiology. Investigation results permit to state a question on advisability of transition to differential chest fluoroscopic examination in persons of A category, being guided by clinical indications and potential risk of carcinogenesis and tuberculosis. 5 refs

  8. An experimental microangiographic study on radiation injury: Microangiography in radiation-injured rabbit kidney

    International Nuclear Information System (INIS)

    Han, Man Chung; Chang, Kee Hyun; Yoo, Seong Yul; Yeon, Kyung Mo; Kim, Chu Wan

    1980-01-01

    Microangiography may be defined as a branch of radiology which deals with the production and study of roentgenograms of thin sections of tissue for evaluation of microvasculatures. Its main advantage is that it permits study of a vascular system in continuity so that the pattern and overall architecture can be appreciated. Authors performed the microangiography to study the irradiation changes of kidney in 30 rabbits. Following local irradiation of 2,000 rads to one kidney of each rabbit, both normal and irradiated kidneys of each rabbit were studied. The results are as follows; 1. In the normal kidneys there is good filling of interiobular arteries, afferent arterioies, glomeruli and efferent arterioies. 2. In the early stage 91 month) after irradiation there appears to be no identifiable abnormal findings except slightly poor filling of glomeruli in the irradiated kidneys. 3. 5 months after irradiation the radiation-injured kidneys reveal intense curling and spralling of interlobular arterials and afferent arterioles with poor filling of glomeruli. 4. Microangiography, as expected, proved to be of good value in evaluation of the microvasculature of the kidney.

  9. The anterior choroidal artery syndrome. Pt. 2. CT and/or MR in angiographically verified cases

    International Nuclear Information System (INIS)

    Takahashi, S.; Ishii, K.; Matsumoto, K.; Higano, S.; Ishibashi, T.; Suzuki, M.; Sakamoto, K.

    1994-01-01

    We reviewed 12 cases of infarcts in the territory of the anterior choroidal artery (AChA) on CT and/or MRI. In each case vascular occlusion in the region was verified angiographically. Although the extent of the lesion on CT/MR images was variable, all were located on the axial images within an arcuate zone between the striatium anterolaterally and the thalamus posteromedially. The distribution of the lesions on mutiplanar MRI conformed well to the territory of the AChA demonstrated microangiographically. The variability of the extent of the infarcts may be explained by variations in the degree of occlusive changes in the AChA or the development of collateral circulation through anastomoses between the AChA and the posterior communicating and posterior cerebral arteries. The extent of the lesion appeared to be closely related to the degree of neurological deficit. (orig.)

  10. Fluoroscopy without the grid: a method of reducing the radiation dose

    International Nuclear Information System (INIS)

    Drury, P.; Robinson, A.

    1980-01-01

    The anti-scatter grid has been removed from the fluoroscopic set during the course of over 80 contrast examinations performed routinely during the ordinary workload of a busy paediatric radiology department. This manoeuvre approximatley halves the radiation dose to the patient during both fluoroscopy and radiography. Experience suggests that the degree of loss of contrast consequent on the abandonment of the grid is diagnostically acceptable during many examinations performed on children (of all ages), when balanced against the lower radiation dose received. In addition, an assessment has been made of the contrast improvement factor of the grids in two fluoroscopic sets in common use, using tissue-equivalent phantoms of various thicknesses. Although the contrast was significantly improved by the use of the grid, to a degree dependent on various factors, the relevance of this improvement in clinical radiology depends on exactly what information is being sought. It is recommended that radiologists should use the grid with discretion when performing fluoroscopic examinations on children and that the apparatus for such examinations should have the capability for easy removal and reintroduction of the grid. (author)

  11. 21 CFR 1020.32 - Fluoroscopic equipment.

    Science.gov (United States)

    2010-04-01

    ... manufacturer shall provide to users, under § 1020.30(h)(1)(i), precautions concerning the importance of remote... specified in § 1020.32(d)(1)(v). (iii) Equipment provided with both an AERC mode and a manual mode shall not... shall be operable only when continuous manual activation is provided by the operator. A continuous...

  12. Balloon dilation and airway stenting for benign and malignant tracheal stenosis

    International Nuclear Information System (INIS)

    Guo Jianhai; Yang Renjie; Zhang Hongzhi

    2009-01-01

    Objective: To assess the effectiveness of balloon dilation and airway stenting performed under fluoroscopic guidance for the treatment of benign and malignant tracheal stenosis. Methods: Under fluoroscopic guidance, balloon dilation and airway stenting were performed in 45 patients with tracheobronchial stricture. Of the 45 patients,malignant tracheal stenosis was seen in 37, including mediastinal nodal metastases (n=14), esophageal carcinoma (n=13), lung carcinoma (n= 4), adenocarcinoma of bronchus (n=3), lymphoma (n=2) and laryngocarcinoma (n=1), and benign tracheal stenosis was seen in 8, including endobronchial tuberculosis (n=6), retrosternal thyroid adenoma (n=1) and endotracheal intubation (n=1). Airway stenting with self-expandable metal stent was employed in 38 patients and balloon dilation in 7 patients. All the procedures were performed under fluoroscopic guidance. Results: A total of 53 self-expandable metal stents was implanted in 38 patients. The clinical symptoms were immediately relived after the procedure in all patients except for one patient who died from choking of sputum. No stent migration was observed. Restenosis developed in 4 patients, which was successfully treated with repeated stenting and balloon dilation. Nineteen times of balloon dilation procedure were accomplished in 7 patients. Marked remission of clinical symptoms was seen in most cases. During a follow-up period (ranged from 0 to 124 months with a mean of 24.5 months) 31 patients died. Conclusion: For both benign and malignant tracheal stenosis, balloon dilation with airway stenting performed under fluoroscopic guidance is a safe and efficient therapy with instant curative effect in relieving clinical symptoms. (authors)

  13. Dosimetry during intramedullary nailing of the tibia.

    Science.gov (United States)

    Kirousis, George; Delis, Harry; Megas, Panagiotis; Lambiris, Elias; Panayiotakis, George

    2009-10-01

    Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. The mean operation time was 101 (48-240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy x cm(2). The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique.

  14. Balloon catheter dilatation of esophageal strictures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeung Sook; Yoon, Yup; Sung, Dong Yook; Choi, Woo Suk; Nam, Kyung Jin; Lim, Jae Hoon [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    1990-07-15

    The authors performed 27 fluoroscopically guided balloon dilatation in 12 patients of esophageal stricture during recent 3 years. The causes of esophageal stricture were corrosive esophagitis (N=2) and congenital narrowing (N=1), including postoperative narrowing in achalasia (N=3), esophageal varix (N=3), lye stricture (N=2) and esophageal cancer (N=1). Successful dilatation of the stricture was achieved during the procedure in 10 patients(83%). Major complication such as esophageal rupture was not found. The authors conclude that fluoroscopically guided esophageal balloon dilatation is a safe and effective method for treatment of symptomatic esophageal strictures.

  15. Balloon catheter dilatation of esophageal strictures

    International Nuclear Information System (INIS)

    Kim, Jeung Sook; Yoon, Yup; Sung, Dong Yook; Choi, Woo Suk; Nam, Kyung Jin; Lim, Jae Hoon

    1990-01-01

    The authors performed 27 fluoroscopically guided balloon dilatation in 12 patients of esophageal stricture during recent 3 years. The causes of esophageal stricture were corrosive esophagitis (N=2) and congenital narrowing (N=1), including postoperative narrowing in achalasia (N=3), esophageal varix (N=3), lye stricture (N=2) and esophageal cancer (N=1). Successful dilatation of the stricture was achieved during the procedure in 10 patients(83%). Major complication such as esophageal rupture was not found. The authors conclude that fluoroscopically guided esophageal balloon dilatation is a safe and effective method for treatment of symptomatic esophageal strictures

  16. Use of gadolinium chelate to confirm epidural needle placement in patients with an iodinated contrast reaction

    International Nuclear Information System (INIS)

    Shetty, Sanjay K.; Nelson, Erik N.; Lawrimore, Tara M.; Palmer, William E.

    2007-01-01

    When performing epidural steroid injections for the management of chronic back pain, imaging guidance and a limited epidurogram improve accuracy of needle placement and ensure appropriate delivery of the injectate into the epidural space. We describe our experience using a gadolinium chelate as an alternative contrast agent for limited epidurography in patients with a history of an iodinated contrast reaction. Thirty-eight of 2,067 (1.8%) epidural steroid injections performed in our department over a 25-month period (December 2003-January 2006) employed gadolinium. All injections were performed in the lumbar spine employing a paramedian interlaminar approach. Procedural notes and patient charts were reviewed to evaluate for immediate or delayed complications related to incorrect intrathecal or intravascular needle placement. A retrospective analysis of selected fluoroscopic spot images was performed to evaluate confidence of epidural needle placement; this analysis compared these spot images against those obtained from age- and gender-matched control patients in whom iodinated contrast was used to confirm needle placement. Real-time fluoroscopic guidance permitted confident visualization of an epidurogram at the time of procedure in all 38 cases as documented in the procedural report, and no procedure resulted in a complication due to incorrect needle placement. Retrospective review of fluoroscopic spot images revealed at least moderate confidence of epidural needle placement by both readers in 29/38 cases (76.3%). Fluoroscopic spot images obtained using gadolinium yielded significantly less confidence than images obtained in control patients whose procedures were performed using iodinated contrast (P < 0.01). However, operators were sufficiently confident in needle placement based on real-time fluoroscopic images (not available in our subsequent review) to inject anesthestic in all 38 cases, despite the immediate consequences that could result from intrathecal

  17. Use of gadolinium chelate to confirm epidural needle placement in patients with an iodinated contrast reaction

    Energy Technology Data Exchange (ETDEWEB)

    Shetty, Sanjay K. [Massachusetts General Hospital, Harvard Medical School, Division of Musculoskeletal Radiology, Department of Radiology, Boston, MA (United States); Beth Israel Deaconess Medical Center, Harvard Medical School, Department of Radiology, Boston, MA (United States); Nelson, Erik N.; Lawrimore, Tara M.; Palmer, William E. [Massachusetts General Hospital, Harvard Medical School, Division of Musculoskeletal Radiology, Department of Radiology, Boston, MA (United States)

    2007-04-15

    When performing epidural steroid injections for the management of chronic back pain, imaging guidance and a limited epidurogram improve accuracy of needle placement and ensure appropriate delivery of the injectate into the epidural space. We describe our experience using a gadolinium chelate as an alternative contrast agent for limited epidurography in patients with a history of an iodinated contrast reaction. Thirty-eight of 2,067 (1.8%) epidural steroid injections performed in our department over a 25-month period (December 2003-January 2006) employed gadolinium. All injections were performed in the lumbar spine employing a paramedian interlaminar approach. Procedural notes and patient charts were reviewed to evaluate for immediate or delayed complications related to incorrect intrathecal or intravascular needle placement. A retrospective analysis of selected fluoroscopic spot images was performed to evaluate confidence of epidural needle placement; this analysis compared these spot images against those obtained from age- and gender-matched control patients in whom iodinated contrast was used to confirm needle placement. Real-time fluoroscopic guidance permitted confident visualization of an epidurogram at the time of procedure in all 38 cases as documented in the procedural report, and no procedure resulted in a complication due to incorrect needle placement. Retrospective review of fluoroscopic spot images revealed at least moderate confidence of epidural needle placement by both readers in 29/38 cases (76.3%). Fluoroscopic spot images obtained using gadolinium yielded significantly less confidence than images obtained in control patients whose procedures were performed using iodinated contrast (P < 0.01). However, operators were sufficiently confident in needle placement based on real-time fluoroscopic images (not available in our subsequent review) to inject anesthestic in all 38 cases, despite the immediate consequences that could result from intrathecal

  18. Ultrasound-guided lumbar puncture in pediatric patients: technical success and safety.

    Science.gov (United States)

    Pierce, David B; Shivaram, Giri; Koo, Kevin S H; Shaw, Dennis W W; Meyer, Kirby F; Monroe, Eric J

    2018-06-01

    Disadvantages of fluoroscopically guided lumbar puncture include delivery of ionizing radiation and limited resolution of incompletely ossified posterior elements. Ultrasound (US) allows visualization of critical soft tissues and the cerebrospinal fluid (CSF) space without ionizing radiation. To determine the technical success and safety of US-guided lumbar puncture in pediatric patients. A retrospective review identified all patients referred to interventional radiology for lumbar puncture between June 2010 and June 2017. Patients who underwent lumbar puncture with fluoroscopic guidance alone were excluded. For the remaining procedures, technical success and procedural complications were assessed. Two hundred and one image-guided lumbar punctures in 161 patients were included. Eighty patients (43%) had previously failed landmark-based attempts. One hundred ninety-six (97.5%) patients underwent lumbar puncture. Five procedures (2.5%) were not attempted after US assessment, either due to a paucity of CSF or unsafe window for needle placement. Technical success was achieved in 187 (95.4%) of lumbar punctures attempted with US guidance. One hundred seventy-seven (90.3%) were technically successful with US alone (age range: 2 days-15 years, weight range: 1.9-53.1 kg) and an additional 10 (5.1%) were successful with US-guided thecal access and subsequent fluoroscopic confirmation. Three (1.5%) cases were unsuccessful with US guidance but were subsequently successful with fluoroscopic guidance. Of the 80 previously failed landmark-based lumbar punctures, 77 (96.3%) were successful with US guidance alone. There were no reported complications. US guidance is safe and effective for lumbar punctures and has specific advantages over fluoroscopy in pediatric patients.

  19. Angiographic Guidewire with Measuring Markers: Design and Clinical Experience

    International Nuclear Information System (INIS)

    Kamei, Seiji; Ishiguchi, Tsuneo; Murata, Katsuhito; Matsuda, Joe; Ohno, Ryota; Kimura, Junko; Nakamura, Atsushi; Ohno, Kazuko; Kawamura, Toshiki; Ikeda, Mitsuru

    2006-01-01

    Purpose. We have developed an angiographic guidewire with measuring markers to determine accurately how far a guidewire is inserted within a catheter. We investigated whether use of this guidewire reduces the risk of vascular injury and the fluoroscopic time during guidewire manipulations. Methods. Four markers were put on the surface of the guidewire at 80, 100, 110, and 120 cm from the tip. The actual lengths of 54 catheters from seven manufacturers were measured and compared with the nominal lengths. Sixty consecutive patients who underwent angiography were randomized into two groups: in one group guidewires with surface markers were used (marker group) and in the other group, conventional guidewires (control group). For each guidewire insertion, the fluoroscopic time before the guidewire was pushed forward into the vessel lumen was recorded. The number of occasions on which unintentionally the guidewire had already been pushed out of the catheter at the start of fluoroscopy was also evaluated. Results. The actual lengths of all catheters were greater than the nominal lengths by 1.0-11.0 cm. Mean fluoroscopic time for each guidewire insertion was 3.3 sec in the marker group and 5.7 sec in the control group (p < 0.05). Guidewires were unintentionally pushed out of the catheters without fluoroscopy three times (3.6%), in each case in the control group. Conclusion. The guidewire with measuring markers is effective for enhancing safety and in reducing fluoroscopic radiation during angiographic procedures. It is recommended that operators be aware that actual lengths of catheters may vary significantly from the nominal lengths listed; they should be aware of this with any guidewire, but particularly with the angiographic measuring guidewire

  20. Meniscal repair following meniscectomy: Mechanism and protective effect

    International Nuclear Information System (INIS)

    Berjon, J.J.; Munuera, L.; Calvo, M.

    1990-01-01

    Meniscal repair was studied to evaluate the mechanism and its potential protective effects on the articular cartilage in an experimental model consisting of 68 knees of adult dogs on which five different types of medial meniscectomy were performed. The results were assessed by macroscopic, microangiographic, and histological methods, after a sequential follow-up period of 10-450 days. Two different mechanisms of meniscal repair were observed, depending on whether meniscal section had been performed in vascular (total meniscectomy) or avascular (subtotal or partial meniscectomy) zones. It was also observed that the repaired meniscal tissue does not prevent articular cartilage degeneration. This is more closely related to the size of the meniscal fragment preserved at meniscetomy. Due to the biomechanical importance of the meniscus and the lack of functional relevance of the repaired meniscal tissue, the most conservative approach possible to meniscectomy is recommended. (orig.)

  1. Paediatric pelvic imaging: optimisation of dose and technique using digital grid-controlled pulsed fluoroscopy.

    Science.gov (United States)

    Waugh, R; McCallum, H M; McCarty, M; Montgomery, R; Aszkenasy, M

    2001-05-01

    An audit of paediatric pelvic radiographs identified deficiencies in gonad shield placement and radiographic technique. A technique using grid-controlled fluoroscopy (GCF), with hard copy images in frame grab and digital spot image (DSI) format was evaluated to optimise gonad shield placement and reduce the dose given to children with Perthes disease and Developmental Hip Dysplasia (DDH) attending for pelvic radiography. Phantom and patient dose surveys of conventional and fluoroscopic techniques were carried out. Image quality and radiation dose were compared for the frame grab and DSI techniques. Retrospective evaluation was undertaken to compare their clinical acceptability. Both fluoroscopic techniques gave considerably less radiation than conventional non-grid radiography (67-83%, P < 0.05). The frame grab technique gave less radiation than DSI (P < 0.05). There was no significant difference in the clinical acceptability scores of the DSI and frame grab images. Fluoroscopy acquired images are now used since the fluoroscopic techniques give much less dose than conventional radiography and provide images of sufficient quality for clinical assessment. Indeed, as there was no significant difference in clinical usefulness between the frame grab and DSI techniques, it is planned to use frame grab alone, thus gaining additional dose saving.

  2. Respiratory liver motion tracking during transcatheter procedures using guidewire detection

    International Nuclear Information System (INIS)

    Vanegas Orozco, Maria-Carolina; Gorges, Sebastien; Pescatore, Jeremie

    2008-01-01

    Transcatheter chemoembolization of liver tumors is performed under X-ray fluoroscopic image guidance. This is a difficult procedure because the vessels of the liver are constantly moving due to respiration and they are not visible in the X-ray image unless a contrast medium is injected. In order to help the interventional radiologist during the treatment, we propose to superimpose on to the fluoroscopic image a pre-acquired contrast-enhanced 2D or 3D image while accounting for liver motion. Our approach proposes to track the guidewire from frame to frame. Our proposed method can be split into two steps. First the guidewire is automatically detected; then the motion between two frames is estimated using a robust ICP (iterative closest point) algorithm. We have tested our method on simulated X-ray fluoroscopic images of a moving guidewire and applied it on 4 clinical sequences. Simulation demonstrated that the mean precision of our method is inferior to 1 mm. On clinical data, preliminary results demonstrated that this method allows for respiratory motion compensation of liver vessels with a mean accuracy inferior to 3 mm. (orig.)

  3. Protection of staff in interventional radiology

    International Nuclear Information System (INIS)

    Melkamu, M. A.

    2013-04-01

    This project focuses on the interventional radiology. The main objective of this project work was to provide a guidance and advice for occupational exposure and hospital management to optimize radiation protection safety and endorse safety culture. It provides practical information on how to minimize occupational exposure in interventional radiology. In the literature review all considerable parameters to reduce dose to the occupationally exposed are well discussed. These parameters include dose limit, risk estimation, use of dosimeter, personal dose record keeping, analysis of surveillance of occupational dose, investigation levels, and proper use of radiation protection tools and finally about scatter radiation dose rate. In addition the project discusses the ways to reduce occupational exposure in interventional radiology. The methods for dose reduction are minimizing fluoroscopic time, minimizing the number of fluoroscopic image, use of patient dose reduction technologies, use of collimation, planning interventional procedures, positioning in low scattered areas, use of protective shielding, use of appropriate fluoroscopic imaging equipment, giving training for the staff, wearing the dosimeters and know their own dose regularly, and management commitment to quality assurance and quality control system and optimization of radiation protection of safety. (author)

  4. Radiologic fallopian tube catheterization for diagnosis and treatment of proximal tubal obstruction

    International Nuclear Information System (INIS)

    Thurmond, A.S.; Rosch, J.

    1988-01-01

    Seventy-five infertile women in whom proximal fallopian tube obstruction had been demonstrated by conventional hysterosalpingography were managed by means of fluoroscopic transcervical fallopian tube catheterization techniques. The procedure helped avoid surgery for diagnosis and/or treatment of proximal tubal obstruction in 71 women (95%). In 32 patients who had patent tube(s) following the procedure, 15 pregnancies have occurred, 14 intrauterine and one tubal (follow-up, 6 months). Fifteen patients had follow-up studies after recanalization, and 19 of 23 tubes remained patent (83%). Fluoroscopic fallopian tube catheterization improves diagnosis of fallopian tube disease and is a low-cost, nonsurgical treatment for infertility caused by proximal fallopian tube obstruction

  5. Assessment of patient exposure for barium enema examinations

    International Nuclear Information System (INIS)

    Bednarek, D.R.; Rudin, S.; Wong, R.

    1983-01-01

    Methods are described for the assessment of patient exposure during clinical fluoroscopic procedures. Values of the roentgen-area-product (RAP) and their distribution throughout the examination are presented for both single-contrast and double-contrast barium enema studies. The double-contrast procedure was measured to give 50% more radiation to the patient than the single-contrast procedure when the same size optical aperture is used between the intensifier and TV pick-up tube. However, it was possible to decrease the fluoroscopic RAP value by over a factor of two for the double-contrast procedure without an adverse clinical effect by increasing the area of the aperture diaphragm

  6. Accuracy and Consistency of Respiratory Gating in Abdominal Cancer Patients

    International Nuclear Information System (INIS)

    Ge, Jiajia; Santanam, Lakshmi; Yang, Deshan; Parikh, Parag J.

    2013-01-01

    Purpose: To evaluate respiratory gating accuracy and intrafractional consistency for abdominal cancer patients treated with respiratory gated treatment on a regular linear accelerator system. Methods and Materials: Twelve abdominal patients implanted with fiducials were treated with amplitude-based respiratory-gated radiation therapy. On the basis of daily orthogonal fluoroscopy, the operator readjusted the couch position and gating window such that the fiducial was within a setup margin (fiducial-planning target volume [f-PTV]) when RPM indicated “beam-ON.” Fifty-five pre- and post-treatment fluoroscopic movie pairs with synchronized respiratory gating signal were recorded. Fiducial motion traces were extracted from the fluoroscopic movies using a template matching algorithm and correlated with f-PTV by registering the digitally reconstructed radiographs with the fluoroscopic movies. Treatment was determined to be “accurate” if 50% of the fiducial area stayed within f-PTV while beam-ON. For movie pairs that lost gating accuracy, a MATLAB program was used to assess whether the gating window was optimized, the external-internal correlation (EIC) changed, or the patient moved between movies. A series of safety margins from 0.5 mm to 3 mm was added to f-PTV for reassessing gating accuracy. Results: A decrease in gating accuracy was observed in 44% of movie pairs from daily fluoroscopic movies of 12 abdominal patients. Three main causes for inaccurate gating were identified as change of global EIC over time (∼43%), suboptimal gating setup (∼37%), and imperfect EIC within movie (∼13%). Conclusions: Inconsistent respiratory gating accuracy may occur within 1 treatment session even with a daily adjusted gating window. To improve or maintain gating accuracy during treatment, we suggest using at least a 2.5-mm safety margin to account for gating and setup uncertainties

  7. Balloon dilatation for the treatment of stricture of gastrojejunostomy

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yeon Hwa [Lee Rha Hospital, Chungju (Korea, Republic of); Song, Ho Young [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Han, Young Min; Chon, Su Bin; Chung, Gyung Ho; Kim, Chong Soo; Choi, Ki Chul [Chonbuk National University College of Medicine, Chungju (Korea, Republic of)

    1993-07-15

    Enteroenteric anastomotic strictures of UGI tract are common and require treatment if significant obstruction occurs. We performed fluoroscopic guided balloon dilatation in 6 patients who had symptomatic stricture of gastrojejunostomy. The stricture was successfully resolved in 4 patients with benign stricture. But 2 patients with malignant stricture had recurrence of obstructive symptoms 2 weeks later, and they required a stent. Asymptomatic balloon rupture was seen in one patients, but other procedural complications did not occur. We found that fluoroscopic guided balloon dilatation is an effective and safe method in the treatment of anastomotic stricture of gastrojejunostomy. We also found transient effect in malignant gastrojejunal anastomotic strictures, which required an interventional procedure, such as placement of a stent.

  8. Quality control: a measure for optimization of dose in diagnostic radiology

    International Nuclear Information System (INIS)

    Abd Aziz Mhd Ramli; Muhammad Jamal Md Isa; Husaini Salleh

    2002-01-01

    Patient dose should always be a factor that is taken into account when using diagnostic X-ray equipment. There is no doubt that patients receive vastly different radiation doses for same examination under different circumstances and performance as well as safety standard of X-ray generating machine is one of the possible causes for this. MINT's experience in measuring performance and safety standard of X-ray fluoroscopic equipments in the year of 2000 indicated that 70% of the irradiating apparatus tend to deliver unnecessary exposures to patients due to various causes. Improper calibration and the usage of unoptimized fluoroscopic X-ray equipment are identified as two major causes that lead to unoptimized medical exposures to patient

  9. Evaluation

    Directory of Open Access Journals (Sweden)

    Ayman Galhom

    2015-12-01

    Conclusions: Fluoroscopic guided injection and surgery have the highest efficacy and satisfaction rates in managing chronic coccygodynia. Hypermobility and spicules are predictors of failure of conservative therapy.

  10. Esophageal achalasia : results of balloon dilation

    Energy Technology Data Exchange (ETDEWEB)

    Ki, Won Woo; Kang, Sung Gwon; Yoon, Kwon Ha; Kim, Nam Hyeon; Lee, Hyo Jeong; Yoon, Hyun Ki; Sung, Kyu Bo; Song, Ho Young [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    1996-08-01

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia.

  11. Esophageal achalasia : results of balloon dilation

    International Nuclear Information System (INIS)

    Ki, Won Woo; Kang, Sung Gwon; Yoon, Kwon Ha; Kim, Nam Hyeon; Lee, Hyo Jeong; Yoon, Hyun Ki; Sung, Kyu Bo; Song, Ho Young

    1996-01-01

    To evaluate the clinical effectiveness of fluoroscopically guided balloon dilation in the treatment of esophageal achalasia. Under fluoroscopic guidance, 21 balloon dilation procedures were performed in 14 patients with achalasia. A balloon with a diameter of 20 mm was used for the initial attempt.If the patient tolerated this well, the procedure was repeated with a 10-20 mm balloon, placed alongside at the same session. If, however the patient complained of severe chest pain and/or a postprocedural esophagogram showed an improvement,the additional balloon was not used. For patients whose results were unsatisfactory, the dilation procedure was repeated at sessions three to seven days apart. Succesful dilation was achieved in 13 of 14 patients(92.9%), who needed a total of 20 sessions of balloon dilation, ranging from one to three sessions per patient(mean, 1.54 sessions). Esophageal rupture occured in one of 14 patients(7.1%) ; of the 13 patients who underwent a successful dilation procedure, 12(92.3%) were free of recurrent symptoms during the follow-up period of 1-56(mean, 18.5) months. The remaning patient(7.7%) had a recurrence seven months after dilation. Fluoroscopically guided balloon dilation seems to be safe and effective in the treatment of esophageal achalasia

  12. Paediatric pelvic imaging: optimisation of dose and technique using digital grid-controlled pulsed fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Waugh, R.; McCarty, M. [Div. of Radiology, South Cleveland Hospital, South Tees Acute Hospitals NHS Trust, Marton Road, Middlesbrough, Cleveland (United Kingdom); McCallum, H.M. [Regional Medical Physics Dept., South Cleveland Hospital, Middlesbrough (United Kingdom); Montgomery, R. [Dept. of Orthopaedics, South Tees Hospitals NITS Trust, Middlesbrough (United Kingdom); Aszkenasy, M. [Tees and North East Yorkshire NHS Trust, West Lane Hospital, Middlesbrough (United Kingdom)

    2001-05-01

    Background. An audit of paediatric pelvic radiographs identified deficiencies in gonad shield placement and radiographic technique. Objective. A technique using grid-controlled fluoroscopy (GCF), with hard copy images in frame grab and digital spot image (DSI) format was evaluated to optimise gonad shield placement and reduce the dose given to children with Perthes disease and Developmental Hip Dysplasia (DDH) attending for pelvic radiography. Materials and methods. Phantom and patient dose surveys of conventional and fluoroscopic techniques were carried out. Image quality and radiation dose were compared for the frame grab and DSI techniques. Retrospective evaluation was undertaken to compare their clinical acceptability. Results. Both fluoroscopic techniques gave considerably less radiation than conventional non-grid radiography (67-83 %, P < 0.05). The frame grab technique gave less radiation than DSI (P < 0.05). There was no significant difference in the clinical acceptability scores of the DSI and frame grab images. Conclusion. Fluoroscopy acquired images are now used since the fluoroscopic techniques give much less dose than conventional radiography and provide images of sufficient quality for clinical assessment. Indeed, as there was no significant difference in clinical usefulness between the frame grab and DSI techniques, it is planned to use frame grab alone, thus gaining additional dose saving. (orig.)

  13. Paediatric pelvic imaging: optimisation of dose and technique using digital grid-controlled pulsed fluoroscopy

    International Nuclear Information System (INIS)

    Waugh, R.; McCarty, M.; McCallum, H.M.; Montgomery, R.; Aszkenasy, M.

    2001-01-01

    Background. An audit of paediatric pelvic radiographs identified deficiencies in gonad shield placement and radiographic technique. Objective. A technique using grid-controlled fluoroscopy (GCF), with hard copy images in frame grab and digital spot image (DSI) format was evaluated to optimise gonad shield placement and reduce the dose given to children with Perthes disease and Developmental Hip Dysplasia (DDH) attending for pelvic radiography. Materials and methods. Phantom and patient dose surveys of conventional and fluoroscopic techniques were carried out. Image quality and radiation dose were compared for the frame grab and DSI techniques. Retrospective evaluation was undertaken to compare their clinical acceptability. Results. Both fluoroscopic techniques gave considerably less radiation than conventional non-grid radiography (67-83 %, P < 0.05). The frame grab technique gave less radiation than DSI (P < 0.05). There was no significant difference in the clinical acceptability scores of the DSI and frame grab images. Conclusion. Fluoroscopy acquired images are now used since the fluoroscopic techniques give much less dose than conventional radiography and provide images of sufficient quality for clinical assessment. Indeed, as there was no significant difference in clinical usefulness between the frame grab and DSI techniques, it is planned to use frame grab alone, thus gaining additional dose saving. (orig.)

  14. [Measurement of screw length through drilling technique in osteosynthesis of the proximal humerus fractures].

    Science.gov (United States)

    Avcı, Cem Coşkun; Gülabi, Deniz; Sağlam, Necdet; Kurtulmuş, Tuhan; Saka, Gürsel

    2013-01-01

    This study aims to investigate the efficacy of screw length measurement through drilling technique on the reduction of intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures. Between January 2008 and June 2012, 98 patients (34 males, 64 females; mean age 64.4 years; range 35 to 81 years) who underwent osteosynthesis using locking anatomical proximal humerus plates (PHILOS) in our clinic with the diagnosis of Neer type 2, 3 or 4 were included. Two different surgical techniques were used to measure proximal screw length in the plate and patients were divided into two groups based on the technique used. In group 1, screw length was determined by a 3 mm blunt tipped Kirschner wire without fluoroscopic control. In group 2, bilateral fluoroscopic images for each screw at least were obtained. Intraarticular screw penetration was detected in five patients (10.6%) in group 1, and in 19 patients (37.3%) in group 2. The mean fluoroscopic imaging time was 10.6 seconds in group 1 and 24.8 seconds in group 2, indicating a statistically significant difference. Screw length measurement through the drilling technique significantly reduces the intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures using PHILOS plates.

  15. Postoperative irradiation after reconstructive surgery: comparative study of radiosensitivity between free-skin grafts and skin flaps

    International Nuclear Information System (INIS)

    Sumi, Y.; Ueda, M.; Kaneda, T.; Oka, T.; Torii, S.; Sakuma, S.

    1984-01-01

    Radiation effects after reconstructive surgery (free-skin grafts and skin flaps) were studied in the rat, and the optimum time for irradiation was determined. The radiosensitivity of both free-skin grafts and skin flaps showed the same trend depending on time of irradiation after operation. The grafts or flaps irradiated in the hypervascular stage showed severe reactions to irradiation, whereas those irradiated in the hypovascular stage showed milder reactions in gross and microangiographic observation. Vascular damage should be given primary consideration when deciding the proper time for irradiation after reconstructive surgery. In general, free-skin grafts showed more severe reactions than skin flaps, especially in the grafts irradiated in the early stage after operation. The experimental results of this study cannot be readily transferred to a clinical setting, but they suggest that postoperative irradiation could be begun 3 to 4 weeks after operation with respect to graft or flap survival, and the results of the clinical cases almost coincide with these experimental results

  16. Fluoroscopic guided benign oesophageal stricture dilatation in ...

    African Journals Online (AJOL)

    Gilliard bougienage (SGB) with balloon dilatation and the combination of both methods for the treatment of BOSs in children at Universitas Hospital, Bloemfontein, South Africa. Methods. A retrospective review of the patient notes on all children 12 ...

  17. Skin dose mapping for fluoroscopically guided interventions.

    Science.gov (United States)

    Johnson, Perry B; Borrego, David; Balter, Stephen; Johnson, Kevin; Siragusa, Daniel; Bolch, Wesley E

    2011-10-01

    To introduce a new skin dose mapping software system for interventional fluoroscopy dose assessment and to analyze the benefits and limitations of patient-phantom matching. In this study, a new software system was developed for visualizing patient skin dose during interventional fluoroscopy procedures. The system works by translating the reference point air kerma to the location of the patient's skin, which is represented by a computational model. In order to orient the model with the x-ray source, geometric parameters found within the radiation dose structured report (RDSR) are used along with a limited number of in-clinic measurements. The output of the system is a visual indication of skin dose mapped onto an anthropomorphic model at a resolution of 5 mm. In order to determine if patient-dependent and patient-sculpted models increase accuracy, peak skin dose was calculated for each of 26 patient-specific models and compared with doses calculated using an elliptical stylized model, a reference hybrid model, a matched patient-dependent model and one patient-sculpted model. Results were analyzed in terms of a percent difference using the doses calculated using the patient-specific model as the true standard. Anthropometric matching, including the use of both patient-dependent and patient-sculpted phantoms, was shown most beneficial for left lateral and anterior-posterior projections. In these cases, the percent difference using a reference model was between 8 and 20%, using a patient-dependent model between 7 and 15%, and using a patient-sculpted model between 3 and 7%. Under the table tube configurations produced errors less than 5% in most situations due to the flattening affects of the table and pad, and the fact that table height is the main determination of source-to-skin distance for these configurations. In addition to these results, several skin dose maps were produced and a prototype display system was placed on the in-clinic monitor of an interventional fluoroscopy system. The skin dose mapping program developed in this work represents a new tool that, as the RDSR becomes available through automated export or real-time streaming, can provide the interventional physician information needed to modify behavior when clinically appropriate. The program is nonproprietary and transferable, and also functions independent to the software systems already installed on the control room workstation. The next step will be clinical implementation where the workflow will be optimized along with further analysis of real-time capabilities.

  18. Fluoroscopic and arthrographic evaluation of carpal instability

    Energy Technology Data Exchange (ETDEWEB)

    Braunstein, E.M.; Louis, D.S.; Greene, T.L.; Hankin, F.M.

    1985-06-01

    The efficacy of a diagnostic protocol involving videotape fluoroscopy of carpal motion and radiocarpal arthrography was evaluated in patients with wrist pain unexplained by physical examination and conventional radiographs. Videotape fluoroscopy was performed as the first study in 68 consecutive cases and was positive in 44 (66%). Radiocarpal arthrography was performed after videotape fluoroscopy in 39 of the cases (57%), including the 24 in which videotape fluoroscopy was normal and 15 others in which further information was desired in spite of positive videotape fluoroscopy. The addition of radiocarpal arthrography to videotape fluoroscopy increased the diagnostic yield to 52 (76%) of the 68 cases and excluded significant anatomic or dynamic abnormality in the others. The diagnosis was proven surgically in 25 cases. This protocol was efficacious for ligament tears of the proximal carpal row, triangular fibrocartilage tears, and proximal and midcarpal instability.

  19. [Routine fluoroscopic investigations after primary bariatric surgery].

    Science.gov (United States)

    Gärtner, D; Ernst, A; Fedtke, K; Jenkner, J; Schöttler, A; Reimer, P; Blüher, M; Schön, M R

    2016-03-01

    Staple line and anastomotic leakages are life-threatening complications after bariatric surgery. Upper gastrointestinal (GI) tract X-ray examination with oral administration of a water-soluble contrast agent can be used to detect leaks. The aim of this study was to evaluate the impact of routine upper GI tract fluoroscopy after primary bariatric surgery. Between January 2009 and December 2014 a total of 658 bariatric interventions were carried out of which 442 were primary bariatric operations. Included in this single center study were 307 sleeve gastrectomies and 135 Roux-en-Y gastric bypasses. Up to December 2012 upper GI tract fluoroscopy was performed routinely between the first and third postoperative days and the detection of leakages was evaluated. In the investigation period 8 leakages (2.6 %) after sleeve gastrectomy, 1 anastomotic leakage in gastrojejunostomy and 1 in jejunojejunostomy after Roux-en-Y gastric bypass occurred. All patients developed clinical symptoms, such as abdominal pain, tachycardia or fever. In one case the leakage was detected by upper GI fluoroscopy and in nine cases radiological findings were unremarkable. No leakages were detected in asymptomatic patients. Routine upper GI fluoroscopy is not recommended for uneventful postoperative courses after primary bariatric surgery.

  20. 75 FR 8375 - Device Improvements to Reduce Unnecessary Radiation Exposure From Medical Imaging; Public Meeting...

    Science.gov (United States)

    2010-02-24

    ... hardware and software features should manufacturers build into CT and fluoroscopic devices in order to... ALARA concept (maintaining dose As Low As Reasonably Achievable) and utilize or provide for...

  1. Constancy of radiation output during diagnostic X-ray exposures

    International Nuclear Information System (INIS)

    Ardran, G.M.; Crooks, H.E.; Birch, R.

    1978-01-01

    Variation in X-ray output and quality during a diagnostic exposure can be undesirable and may result in unnecessary dose to the patient. When significant build-up or decay periods are present errors will arise if factors obtained under steady-state conditions are employed to estimate the exposure. These parameters must be taken into account when calibrating X-ray generators. A variable speed spinning film device and a spectrometry system have been used to measure the variations under fluoroscopic and radiographic conditions for a number of generators. Variations in output due to filament heating, voltage supply and rectification, cable capacity and target pitting have been demonstrated. At low fluoroscopic currents, large surges and long decays have been observed; the significance of these effects is considered. (author)

  2. Lumbar pedicle screw placement: Using only AP plane imaging

    Directory of Open Access Journals (Sweden)

    Anil Sethi

    2012-01-01

    Conclusion: Placement of pedicle screws under fluoroscopic guidance using AP plane imaging alone with tactile guidance is safe, fast, and reliable. However, a good understanding of the radiographic landmarks is a prerequisite.

  3. The establishment of Digital Image Capture System(DICS) using conventional simulator

    International Nuclear Information System (INIS)

    Oh, Tae Sung; Park, Jong Il; Byun, Young Sik; Shin, Hyun Kyoh

    2004-01-01

    The simulator is used to determine patient field and ensure the treatment field, which encompasses the required anatomy during patient normal movement such as during breathing. The latest simulator provide real time display of still, fluoroscopic and digitalized image, but conventional simulator is not yet. The purpose of this study is to introduce digital image capture system(DICS) using conventional simulator and clinical case using digital captured still and fluoroscopic image. We connect the video signal cable to the video terminal in the back up of simulator monitor, and connect the video jack to the A/D converter. After connection between the converter jack and computer, We can acquire still image and record fluoroscopic image with operating image capture program. The data created with this system can be used in patient treatment, and modified for verification by using image processing software. (j.e. photoshop, paintshop) DICS was able to establish easy and economical procedure. DCIS image was helpful for simulation. DICS imaging was powerful tool in the evaluation of the department specific patient positioning. Because the commercialized simulator based of digital capture is very expensive, it is not easily to establish DICS simulator in the most hospital. DICS using conventional simulator enable to utilize the practical use of image equal to high cost digitalized simulator and to research many clinical cases in case of using other software program.

  4. Intraoperative CT in the assessment of posterior wall acetabular fracture stability.

    Science.gov (United States)

    Cunningham, Brian; Jackson, Kelly; Ortega, Gil

    2014-04-01

    Posterior wall acetabular fractures that involve 10% to 40% of the posterior wall may or may not require an open reduction and internal fixation. Dynamic stress examination of the acetabular fracture under fluoroscopy has been used as an intraoperative method to assess joint stability. The aim of this study was to demonstrate the value of intraoperative ISO computed tomography (CT) examination using the Siemens ISO-C imaging system (Siemens Corp, Malvern, Pennsylvania) in the assessment of posterior wall acetabular fracture stability during stress examination under anesthesia. In 5 posterior wall acetabular fractures, standard fluoroscopic images (including anteroposterior pelvis and Judet radiographs) with dynamic stress examinations were compared with the ISO-C CT imaging system to assess posterior wall fracture stability during stress examination. After review of standard intraoperative fluoroscopic images under dynamic stress examination, all 5 cases appeared to demonstrate posterior wall stability; however, when the intraoperative images from the ISO-C CT imaging system demonstrated that 1 case showed fracture instability of the posterior wall segment during stress examination, open reduction and internal fixation was performed. The use of intraoperative ISO CT imaging has shown an initial improvement in the surgeon's ability to assess the intraoperative stability of posterior wall acetabular fractures during stress examination when compared with standard fluoroscopic images. Copyright 2014, SLACK Incorporated.

  5. Tumor motion prediction with the diaphragm as a surrogate: a feasibility study

    International Nuclear Information System (INIS)

    Cervino, Laura I; Jiang Yan; Sandhu, Ajay; Jiang, Steve B

    2010-01-01

    We have previously assessed the use of the diaphragm as a surrogate for predicting real-time tumor position with linear models built with training data extracted from the same treatment fraction (Cervino et al 2009 Phys. Med. Biol. 54 3529-41). However, practical use in the clinical setting requires the capability of predicting tumor position throughout the treatment course using a model built at the beginning of the course. We evaluate the inter-fraction applicability of linear models to predict superior-inferior tumor position based on diaphragm position using 21 fluoroscopic sequences from five lung cancer patients. Tumor position is predicted with models built during the first fluoroscopic sequence of each patient. Other fluoroscopic sets are registered to the first set with five different methods. The mean localization prediction error and maximum error at a 95% confidence level averaged over all patients are found to be 1.2 mm and 2.9 mm, respectively, for bony registration and 1.2 mm and 2.8 mm, respectively, for registration based on the mean position of the tumor in the first two breathing cycles. Other registration methods produce larger prediction errors. In the clinical setting, this prediction error could be added as a margin to the target volume. We therefore conclude that it is feasible to predict lung tumor motion with diaphragm with sufficient accuracy in the clinical setting. (note)

  6. Assessment of peak skin dose in interventional cardiology: A comparison between Gafchromic film and dosimetric software em.dose.

    Science.gov (United States)

    Greffier, J; Van Ngoc Ty, C; Bonniaud, G; Moliner, G; Ledermann, B; Schmutz, L; Cornillet, L; Cayla, G; Beregi, J P; Pereira, F

    2017-06-01

    To compare the use of a dose mapping software to Gafchromic film measurement for a simplified peak skin dose (PSD) estimation in interventional cardiology procedure. The study was conducted on a total of 40 cardiac procedures (20 complex coronary angioplasty of chronic total occlusion (CTO) and 20 coronary angiography and coronary angioplasty (CA-PTCA)) conducted between January 2014 to December 2015. PSD measurement (PSD Film ) was obtained by placing XR-RV3 Gafchromic under the patient's back for each procedure. PSD (PSD em.dose ) was computed with the software em.dose©. The calculation was performed on the dose metrics collected from the private dose report of each procedure. Two calculation methods (method A: fluoroscopic kerma equally spread on cine acquisition and B: fluoroscopic kerma is added to one air Kerma cine acquisition that contributes to the PSD) were used to calculate the fluoroscopic dose contribution as fluoroscopic data were not recorded in our interventional room. Statistical analyses were carried out to compare PSD Film and PSD em.dose . The PSD Film median (1st quartile; 3rd quartile) was 0.251(0.190;0.336)Gy for CA-PTCA and 1.453(0.767;2.011)Gy for CTO. For method-A, the PSD em.dose was 0.248(0.182;0.369)Gy for CA-PTCA and 1.601(0.892;2.178)Gy for CTO, and 0.267(0.223;0.446)Gy and 1.75 (0.912;2.584)Gy for method-B, respectively. For the two methods, the correlation between PSD Film and PSD em.dose was strong. For all cardiology procedures investigated, the mean deviation between PSD Film and PSD em.dose was 3.4±21.1% for method-A and 17.3%±23.9% for method-B. The dose mapping software is convenient to calculate peak skin dose in interventional cardiology. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. The use of low-osmolar water-soluble contrast in videofluoroscopic swallowing exams.

    Science.gov (United States)

    Harris, Julie A; Bartelt, Detlef; Campion, Molly; Gayler, Bob W; Jones, Bronwyn; Hayes, Andrea; Haynos, Judith; Herbick, Seanne; Kling, Therese; Lingaraj, Arpana; Singer, Michele; Starmer, Heather; Smith, Christine; Webster, Kim

    2013-12-01

    The selection of the contrast agent used during fluoroscopic exams is an important clinical decision. The purpose of this article is to document the usage of a nonionic, water-soluble contrast (iohexol) and barium contrast in adult patients undergoing fluoroscopic exams of the pharynx and/or esophagus and provide clinical indications for the use of each. For 1 year, data were collected on the use of iohexol and barium during fluoroscopic exams. The contrast agent used was selected by the speech language pathologist (SLP) or the radiologist based on the exam's indications. A total of 1,978 fluoroscopic exams were completed in the 12-month period of documentation. Of these exams, 60.6 % were completed for medical reasons and 39.4 % for surgical reasons. Fifty-five percent of the exams were performed jointly by a SLP and a radiologist and 45 % were performed by a radiologist alone. Aspiration was present in 22 % of the exams, vestibular penetration occurred in 38 %, extraluminal leakage of contrast was observed in 4.6 %, and both aspiration and leakage were seen in 1 % of the exams. In cases with aspiration, iohexol was used alone in 8 %, iohexol and barium were both used in 45 %, and barium was used alone in 47 %. In cases with extraluminal leakage, iohexol was used alone in 58 %, iohexol and barium were both used in 31 %, and barium was used alone in 11 %. No adverse effects were seen with the use of iohexol. When barium was used in cases of aspiration and extraluminal leakage, the amount of aspirated barium was small and the extraluminal barium in the instances of leakage was small. Iohexol is a useful screening contrast agent and can safely provide information, and its use reduces the risk of aspiration and the chance of leakage of large amounts of barium.

  8. Interventional radiography and mortality risks in U.S. radiologic technologists

    Energy Technology Data Exchange (ETDEWEB)

    Linet, Martha S.; Freedman, D.M.; Sigurdson, Alice J.; Doody, Michele M. [National Cancer Institute, Radiation Epidemiology Branch, Division of Cancer Epidemiology and Genetics, Bethesda, MD (United States); Hauptmann, Michael [National Cancer Institute, Biostatistics Branch, Division of Cancer Epidemiology and Genetics, Bethesda, MD (United States); Alexander, Bruce H. [University of Minnesota, Division of Environmental Health Sciences, Minneapolis, MN (United States); Miller, Jeremy [Information Management Services, Inc., Rockville, MD (United States)

    2006-09-15

    With the exponential increase in minimally invasive fluoroscopically guided interventional radiologic procedures, concern has increased about the health effects on staff and patients of radiation exposure from these procedures. There has been no systematic epidemiologic investigation to quantify serious disease risks or mortality. To quantify all-cause, circulatory system disease and cancer mortality risks in U.S. radiologic technologists who work with interventional radiographic procedures, we evaluated mortality risks in a nationwide cohort of 88,766 U.S. radiologic technologists (77% female) who completed a self-administered questionnaire during 1994-1998 and were followed through 31 December 2003. We obtained information on work experience, types of procedures (including fluoroscopically guided interventional procedures), and protective measures plus medical, family cancer history, lifestyle, and reproductive information. Cox proportional hazards regression models were used to compute relative risks (RRs) with 95% confidence intervals (CIs). Between completion of the questionnaire and the end of follow-up, there were 3,581 deaths, including 1,209 from malignancies and 979 from circulatory system diseases. Compared to radiologic technologists who never or rarely performed or assisted with fluoroscopically guided interventional procedures, all-cause mortality risks were not increased among those working on such procedures daily. Similarly, there was no increased risk of mortality resulting from all circulatory system diseases combined, all cancers combined, or female breast cancer among technologists who daily performed or assisted with fluoroscopically guided interventional procedures. Based on small numbers of deaths (n=151), there were non-significant excesses (40%-70%) in mortality from cerebrovascular disease among technologists ever working with these procedures. The absence of significantly elevated mortality risks in radiologic technologists reporting the

  9. Myelography

    Science.gov (United States)

    ... the fluoroscope , which projects radiographic images in a movie-like sequence onto the monitor, to visualize the ... evaluation. National and international radiology protection organizations continually review and update the technique standards used by radiology ...

  10. Digital fluoroscopy: Technique and applications for evaluating left ventricular function

    International Nuclear Information System (INIS)

    Higgins, C.B.; Norris, S.L.; Gerber, K.H.; Ashburn, W.L.; Slutsky, R.A.

    1985-01-01

    Central cardiovascular dynamics can be studied without cardiac catheterization by digital processing of fluoroscopic images of the heart obtained after central intravenous injection of contrast media. While digital subtraction angiography has been used for studying peripheral vasculature for several years, it is only recently that this technique has been applied for assessing cardiac morphology and physiology. The conversion of fluoroscopic x-ray data into a digital form has an added advantage for the study of the central cardiovascular system since it not only permits contrast enhancement of the images but also facilitates quantitative and functional analysis of the x-ray data. The several applications described in this chapter suggest that digital subtraction cardiovascular angiography will prove to be a powerful tool for studying cardiovascular physiology in animals and for evaluating heart disease in patients

  11. Pharyngoceles aspects in imaging exams

    International Nuclear Information System (INIS)

    Diniz, Fabio de Vilhena; Nakamura, Olavo Kyosen; Grassi, Caio Giometti; Barbosa Junior, Alcino Alves; Gomes, Regina Lucia Elia; Daniel, Mauro Miguel; Garcia, Marcio Ricardo Taveira; Funari, Marcelo Buarque de Gusmao

    2010-01-01

    Objective: the present study is aimed at showing the different characteristics of pharyngoceles in imaging exams (video fluoroscopic swallowing exam [VFSE] and computed tomography) and its correlation with clinical presentation. Material and method: pharyngocele cases were selected in imaging exams (video fluoroscopic swallowing exam [VFSE] and computed tomography) realized in our service, realizing clinical presentation correlation. Results: pharyngocele presents frequently with small dimensions and narrow orifice. When the size enlarges, clinical presentation is more evident and diverse, which can confuse with other cervical lesions that enlarge with Valsalva maneuver. Differential diagnosis can be done by imaging evaluation. Conclusion: we intended to demonstrate that many times pharyngocele can be presented with different aspects, not always being easy to recognize by clinics or imaging exams, but its diagnosis must be always remembered in our daily practice. (author)

  12. Arthrography

    Medline Plus

    Full Text Available ... may be required prior to sedation. You should plan to have a relative or friend drive you ... Image Gallery Musculoskeletal radiologist using fluoroscopic images to plan an ankle arthrogram. View full size with caption ...

  13. Arthrography

    Medline Plus

    Full Text Available ... it is useful to bring that to the attention of the scheduler before the exam and bring ... fluoroscopic images to plan an ankle arthrogram. View full size with caption Pediatric Content Some imaging tests ...

  14. Diagnostic radiology: I

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter describes the historic development of diagnostic equipment for radiology. The problems associated with fluoroscope design are detailed and the current uses of updated technology, particularly digitization, are considered. Numerous historical photographs are included. 13 refs

  15. Foreign Body Retrieval

    Medline Plus

    Full Text Available ... physician may choose to perform surgery using ultrasound guidance. Ultrasound provides real-time imaging, making it a ... the need for anesthesia, intravenous access and fluoroscopic guidance. However, it is typically an outpatient procedure requiring ...

  16. Fluoroscopy- vs ultrasound-guided aspiration techniques in the management of periprosthetic joint infection: which is the best?

    Science.gov (United States)

    Randelli, Filippo; Brioschi, Marco; Randelli, Pietro; Ambrogi, Federico; Sdao, Silvana; Aliprandi, Alberto

    2018-01-01

    Fluid samples obtained from an affected joint still play a central role in the diagnosis of periprosthetic joint infection (PJI). It is the only preoperative test able to discover the causative microbiological agent. In the hip, fluid aspiration can be performed through fluoroscopy, ultrasound, or, less commonly, computed tomography. However, there is still a lack of consensus on which method is preferable in terms of efficacy and costbenefit. We, therefore, asked whether (1) the benefits in terms of sensitivity and specificity and (2) the costs were comparable between fluoroscopy- and ultrasound-guided joint aspirations in a suspicious of hip PJI. Between 2013 and 2016, 52 hip aspirations were performed on 49 patients with clinical, radiological, or serological suspicion of PJI, waiting for a revision surgery. The patients were divided in two groups: fluoroscopy- (n = 26) vs ultrasound-guided hip aspiration group (n = 26). These groups were also divided in control and infected patients. The criteria of MusculoSkeletal Infection Society (MSIS) were used, as gold standard, to define PJI. (1) Ultrasound-guided aspiration revealed valid sensitivity (89% vs 60%) and specificity (94% vs 81%) in comparison with fluoroscopic-guided aspiration. (2) The cost analysis was also in favor of ultrasound-guided aspiration (125.30€) than fluoroscopic-guided aspiration (343.58€). We concluded that ultrasound-guided hip aspiration could represent a valid, safe, and less expensive diagnostic alternative to fluoroscopic-guided aspiration in hip PJI.

  17. Intraoperative dynamic dosimetry for prostate implants

    Energy Technology Data Exchange (ETDEWEB)

    Todor, D A [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Zaider, M [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Cohen, G N [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Worman, M F [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States); Zelefsky, M J [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY 10021 (United States)

    2003-05-07

    This paper describes analytic tools in support of a paradigm shift in brachytherapy treatment planning for prostate cancer - a shift from standard pre-planning to intraoperative planning using dosimetric feedback based on the actual deposited seed positions within the prostate. The method proposed is guided by several desiderata: (a) bringing both planning and evaluation in the operating room (i.e. make post-implant evaluation superfluous) therefore making rectifications - if necessary - still achievable; (b) making planning and implant evaluation consistent by using the same imaging system (ultrasound); and (c) using only equipment commonly found in a hospital operating room. The intraoperative dosimetric evaluation is based on the fusion between ultrasound images and 3D seed coordinates reconstructed from fluoroscopic projections. Automatic seed detection and registration of the fluoroscopic and ultrasound information, two of the three key ingredients needed for the intraoperative dynamic dosimetry optimization (IDDO), are explained in detail. The third one, the reconstruction of 3D coordinates from projections, was reported in a previous article. The algorithms were validated using a custom-designed phantom with non-radioactive (dummy) seeds. Also, fluoroscopic images were taken at the conclusion of an actual permanent prostate implant and compared with data on the same patient obtained from radiographic-based post-implant evaluation. To offset the effect of organ motion the comparison was performed in terms of the proximity function of the two seed distributions. The agreement between the intra- and post-operative seed distributions was excellent.

  18. An Accurate Full-flexion Anterolateral Portal for Needle Placement in the Knee Joint With Dry Osteoarthritis.

    Science.gov (United States)

    Hussein, Mohamed

    2017-07-01

    Accurate delivery of an injection into the intra-articular space of the knee is achieved in only two thirds of knees when using the standard anterolateral portal. The use of a modified full-flexion anterolateral portal provides a highly accurate, less painful, and more effective method for reproducible intra-articular injection without the need for ultrasonographic or fluoroscopic guidance in patients with dry osteoarthritis of the knee. The accuracy of needle placement was assessed in a prospective series of 140 consecutive injections in patients with symptomatic degenerative knee arthritis without clinical knee effusion. Procedural pain was determined using the Numerical Rating Scale. The accuracy rates of needle placement were confirmed with fluoroscopic imaging to document the dispersion pattern of injected contrast material. Using the standard anterolateral portal, 52 of 70 injections were confirmed to have been placed in the intra-articular space on the first attempt (accuracy rate, 74.2%). Using the modified full-flexion anterolateral portal, 68 of 70 injections were placed in the intra-articular space on the first attempt (accuracy rate, 97.1%; P = 0.000). This study revealed that using the modified full-flexion anterolateral portal for injections into the knee joint resulted in more accurate and less painful injections than those performed by the same orthopaedic surgeon using the standard anterolateral portal. In addition, the technique offered therapeutic delivery into the joint without the need for fluoroscopic confirmation. Therapeutic Level II.

  19. In vivo fluoroscopic kinematography of dynamic radio-ulnar ...

    African Journals Online (AJOL)

    ... canine elbow joint, as part of the physiological kinematic pattern. However, dysplastic elbow joints do not show an increased radio-ulnar translation, and therfore dRUI cannot be considered causative for medial coronoid disease. Keywords: Canine, Elbow dysplasia, Fluoroscopy, Gait analysis, Radio-ulnar incongruence.

  20. Patients exposure from fluoroscopic guided pacemaker implantation procedures

    International Nuclear Information System (INIS)

    Alkhorayef, M.; Babikir, E.; Sulieman, A.; Daar, E.; Alnaaimi, M.; Alduaij, M.; Bradley, D.

    2016-10-01

    A pacemaker, which is used for heart re synchronization with electrical impulses, is used to manage many clinical conditions. Recently, the frequency of the pacemaker implantation procedures increased 50% worldwide. During this procedure, patients and staff can be exposed to excessive radiation exposure. Wide range of doses was reported in previous studies, suggesting that optimization of this procedure is not fulfilled yet. This study aims to evaluate the patient and staff radiation doses during cardiac pacemaker procedure and quantify the patient effective dose. A total of 145 procedures were performed for five pacemakers procedures (VVI, VVIR, VVD, VVDR and DDDR) two hospitals were evaluated. Patients doses were measured using the kerma-area product meter. Effective doses were estimated using software based on Monte Carlo simulation from National Radiological Protection Board. The effective dose values were used to estimate the cancer risk from pacemaker procedure. Patients demographic data, exposure parameters for both fluoroscopy and radiography were quantified. The mean patients doses (Gy. cm 2 ) for VVI, VVIR, VVD, VVDR and DDDR was 1.52±0.13 (1.43-1.61), 3.28±2.34 (0.29-8.73), 3.04±1.67 (1.57-4.86), 6.04±2.326 and 19.2±3.6 (5.43-30.2), respectively, per procedure. The overall patients effective dose is 1.1 mSv per procedure. (Author)

  1. Fluoroscopic radiation exposure: are we protecting ourselves adequately?

    Science.gov (United States)

    Hoffler, C Edward; Ilyas, Asif M

    2015-05-06

    While traditional intraoperative fluoroscopy protection relies on thyroid shields and aprons, recent data suggest that the surgeon's eyes and hands receive more exposure than previously appreciated. Using a distal radial fracture surgery model, we examined (1) radiation exposure to the eyes, thyroid, chest, groin, and hands of a surgeon mannequin; (2) the degree to which shielding equipment can decrease exposure; and (3) how exposure varies with fluoroscopy unit size. An anthropomorphic model was fit with radiation-attenuating glasses, a thyroid shield, an apron, and gloves. "Exposed" thermoluminescent dosimeters overlaid the protective equipment at the eyes, thyroid, chest, groin, and index finger while "shielded" dosimeters were placed beneath the protective equipment. Fluoroscopy position and settings were standardized. The mini-c-arm milliampere-seconds were fixed based on the selection of the kilovolt peak (kVp). Three mini and three standard c-arms scanned a model of the patient's wrist continuously for fifteen minutes each. Ten dosimeter exposures were recorded for each c-arm. Hand exposure averaged 31 μSv/min (range, 22 to 48 μSv/min), which was 13.0 times higher than the other recorded exposures. Eye exposure averaged 4 μSv/min, 2.2 times higher than the mean thyroid, chest, and groin exposure. Gloves reduced hand exposure by 69.4%. Glasses decreased eye exposure by 65.6%. There was no significant difference in exposure between mini and standard fluoroscopy. Surgeons' hands receive the most radiation exposure during distal radial plate fixation under fluoroscopy. There was a small but insignificant difference in mean exposure between standard fluoroscopy and mini-fluoroscopy, but some standard units resulted in lower exposure than some mini-units. On the basis of these findings, we recommend routine protective equipment to mitigate exposure to surgeons' hands and eyes, in addition to the thyroid, chest, and groin, during fluoroscopy procedures. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  2. Patients exposure from fluoroscopic guided pacemaker implantation procedures

    Energy Technology Data Exchange (ETDEWEB)

    Alkhorayef, M.; Babikir, E. [King Saud University, College of Applied Sciences, Radiological Sciences Department, P. O. Box 10219, Riyadh 11433 (Saudi Arabia); Sulieman, A. [Prince Sattam bin Abdulaziz University, College of Applied Medical Sciences, Radiology and Medical Imaging Department, P. O. Box 422, Alkharj 11942 (Saudi Arabia); Daar, E. [University of Jordan, Faculty of Science, Department of Physics, Amman 11942 (Jordan); Alnaaimi, M.; Alduaij, M. [Kuwait Cancer Control Centre, Department of Nuclear Medicine, Shwiekh (Kuwait); Bradley, D., E-mail: malkhorayef@ksu.edu.sa [University of Surrey, Centre for Nuclear and Radiation Physics, Guildford, Surrey, GU2 7XH (United Kingdom)

    2016-10-15

    A pacemaker, which is used for heart re synchronization with electrical impulses, is used to manage many clinical conditions. Recently, the frequency of the pacemaker implantation procedures increased 50% worldwide. During this procedure, patients and staff can be exposed to excessive radiation exposure. Wide range of doses was reported in previous studies, suggesting that optimization of this procedure is not fulfilled yet. This study aims to evaluate the patient and staff radiation doses during cardiac pacemaker procedure and quantify the patient effective dose. A total of 145 procedures were performed for five pacemakers procedures (VVI, VVIR, VVD, VVDR and DDDR) two hospitals were evaluated. Patients doses were measured using the kerma-area product meter. Effective doses were estimated using software based on Monte Carlo simulation from National Radiological Protection Board. The effective dose values were used to estimate the cancer risk from pacemaker procedure. Patients demographic data, exposure parameters for both fluoroscopy and radiography were quantified. The mean patients doses (Gy. cm{sup 2}) for VVI, VVIR, VVD, VVDR and DDDR was 1.52±0.13 (1.43-1.61), 3.28±2.34 (0.29-8.73), 3.04±1.67 (1.57-4.86), 6.04±2.326 and 19.2±3.6 (5.43-30.2), respectively, per procedure. The overall patients effective dose is 1.1 mSv per procedure. (Author)

  3. Dry Arthroscopy of the Elbow and Basic Hip Arthroscopy Positioning.

    Science.gov (United States)

    Lubowitz, James H

    2015-08-01

    In Arthroscopy Techniques, dry arthroscopy of the elbow is well-illustrated, and hip arthroscopy patient positioning including fluoroscopic examination under anesthesia is critically reviewed. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  4. Arthrography

    Medline Plus

    Full Text Available ... have a personal story about radiology? Share your patient story here Images × Image Gallery Musculoskeletal radiologist using fluoroscopic images to plan an ankle arthrogram. View full size with caption Pediatric Content Some imaging tests and treatments have special ...

  5. Rotatostereoradiography; a new radiodiagnostic method; Development of a new three-dimensional radiodiagnostic device and evaluation in neurosurgical clinics

    Energy Technology Data Exchange (ETDEWEB)

    Ottomo, Michinori [Aomori Rosai Hospital, Hachinohe (Japan); Basugi, Norihiko; Handa, Hajime; Taniguchi, Takashi; Iwabuchi, Takashi; Kosaka, Mitsuo

    1991-02-01

    The rotatostereoradiographic device uses an x-ray tube coupled with an image intensifier rotating through a 180deg arc in 2.25 seconds. The rapidly rotating x-ray tube allows 180deg -arc angiograms to be obtained with a single injection of contrast medium. Subtracted fluoroscopic angiograms can be viewed immediately after injection of the contrast medium with digital recording. These three-dimensional images are displayed on side-by-side monitors stereoscopically. The mortality and morbidity of subarachnoid hemorrhage can only be greatly reduced by surgical treatment of unruptured aneurysms and arteriovenous malformations detected by a wide survey of subarachnoid hemorrhage. Such a wide survey would be possible utilizing intra-arterial digital subtraction angiography via the ascending aorta and this new three-dimensional radiodiagnostic method. A fluoroscopic device must be used to allow easier manipulation of the catheter from the axillary or brachial artery. (author).

  6. Rotational Mal-Alignment after Reamed Intramedullary Nailing for tibial shaft fracture.

    Science.gov (United States)

    Khan, Sher Baz; Mohib, Yasir; Rashid, Rizwan Haroon; Rashid, Haroonur

    2016-10-01

    Intra-medullary (IM) nailing is standard of care for unstable tibial shaft fractures. Malrotation is very common but it is under-recognised, inpart because of variation in normal anatomy and partly due to difficulty in accurately assessing rotation. This study was planned to evaluate the frequency of rotational mal-alignment after reamed tibia IMnailing. This cross-sectional study was conducted at Aga khan University Hospital, Karachi, and comprised patients with tibia shaft fractures managed with IMnailing from January to December 2014. All the patients were assessed intra-operatively for rotational alignment using the knee and ankle fluoroscopic images. There were 81 patients with a mean age of 38±16.9 years. There were 64(79%) male patients. Overall the incidence of malrotation was in 20(24.7%) cases. Rotational mal-alignment is one of the preventable complications after IMnailing which can be assesed intra-operatively under fluoroscope.

  7. Evaluation of Patient Radiation Dose during Orthopedic Surgery

    International Nuclear Information System (INIS)

    Osman, H; Elzaki, A.; Sam, A.K.; Sulieman, A.

    2013-01-01

    The number of orthopedic procedures requiring the use of the fluoroscopic guidance has increased over the recent years. Consequently the patient exposed to un avoidable radiation doses. The aim of the current study was to evaluate patient radiation dose during these procedures.37 patients under went dynamic hip screw (DHS) and dynamic cannulated screw (DCS) were evaluated using calibrated Thermolumincent Dosimeters (TLDs), under carm fluoroscopic machines ,in three centers in Khartoum-Sudan. The mean Entrance Skin Dose (ESD) was 7.9 m Gy per procedure. The bone marrow and gonad organ exposed to significant doses. No correlation was found between ESD and Body Mass Index (BMI), or patient weight. Well correlation was found between kilo voltage applied and ESD. Orthopedic surgeries delivered lower radiation dose to patients than cardiac catheterization or hysterosalpingraphy (HSG) procedures. More study should be implemented to follow radiation dose before surgery and after surgery

  8. Effective doses and standardised risk factors from paediatric diagnostic medical radiation exposures: Information for radiation risk communication

    International Nuclear Information System (INIS)

    Bibbo, Giovanni

    2018-01-01

    In the paediatric medical radiation setting, there is no consistency on the radiation risk information conveyed to the consumer (patient/carer). Each communicator may convey different information about the level of risk for the same radiation procedure, leaving the consumer confused and frustrated. There is a need to standardise risks resulting from medical radiation exposures. In this study, paediatric radiographic, fluoroscopic, CT and nuclear medicine examination data have been analysed to provide (i) effective doses and radiation induced cancer risk factors from common radiological and nuclear medicine diagnostic procedures in standardised formats, (II) awareness of the difficulties that may be encountered in communicating risks to the layperson, and (iii) an overview of the deleterious effects of ionising radiation so that the risk communicator can convey with confidence the risks resulting from medical radiation exposures. Paediatric patient dose data from general radiographic, computed tomography, fluoroscopic and nuclear medicine databases have been analysed in age groups 0 to <5 years, 5 to <10 years, 10 to <15 years and 15 to <18 years to determine standardised risk factors. Mean, minimum and maximum effective doses and the corresponding mean lifetime risks for general radiographic, fluoroscopic, CT and nuclear medicine examinations for different age groups have been calculated. For all examinations, the mean lifetime cancer induction risk is provided in three formats: statistical, fraction and category. Standardised risk factors for different radiological and nuclear medicine examinations and an overview of the deleterious effects of ionising radiation and the difficulties encountered in communicating the risks should facilitate risk communication to the patient/carer.

  9. Stochastic risk estimation from medical x-ray diagnostic examinations, 2

    International Nuclear Information System (INIS)

    Hashizume, Tadashi; Maruyama, Takashi; Noda, Yutaka; Iwai, Kazuo; Tateno, Y.; Nishizawa, Kanae.

    1981-01-01

    The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination are tabulated in terms of risk level of 10 -6 . In general, the total risk defined as the sum of genetic, leukemia and malignant risks was a high value for the X-ray diagnosis of digestive organs involving barium meal and barium enema. For example, the total risk for young age-group was 100 to 200 x 10 -6 for the X-ray diagnosis of digestive organs. The total risk from the chest radiography was lower value as compared with the risk from the X-ray diagnosis of other organs or tissues. On the contrary, the risk from the chest tomography was comparable to the risk from the diagnosis of digestive organs. The total risk decreased with increasing of age for every X-ray diagnostic examination. (author)

  10. Strategies for Proximal Femoral Nailing of Unstable Intertrochanteric Fractures: Lateral Decubitus Position or Traction Table.

    Science.gov (United States)

    Sonmez, Mesut Mehmet; Camur, Savas; Erturer, Erden; Ugurlar, Meric; Kara, Adnan; Ozturk, Irfan

    2017-03-01

    The aim of this prospective randomized study was to compare the traction table and lateral decubitus position techniques in the management of unstable intertrochanteric fractures. Eighty-two patients with unstable intertrochanteric fractures between 2011 and 2013 were included in this study. All patients were treated surgically with the Proximal Femoral Nail Antirotation implant (DePuy Synthes). Patients were randomized to undergo the procedure in the lateral decubitus position (42 patients) or with the use of a traction table (40 patients). Patients whose procedure was not performed entirely with a semi-invasive method or who required the use of additional fixation materials, such as cables, were excluded from the study. The groups were compared on the basis of the setup time, surgical time, fluoroscopic exposure time, tip-to-apex distance, collodiaphyseal angle, and modified Baumgaertner criteria for radiologic reduction. The setup time, surgical time, and fluoroscopic exposure time were lower and the differences were statistically significant in the lateral decubitus group compared with the traction table group. The collodiaphyseal angles were significantly different between the groups in favor of the lateral decubitus method. The tip-to-apex distance and the classification of reduction according to the modified Baumgaertner criteria did not demonstrate a statistically significant difference between the groups. The lateral decubitus position is used for most open procedures of the hip. We found that this position facilitates exposure for the surgical treatment of unstable intertrochanteric fractures and has advantages over the traction table in terms of set up time, surgical time and fluoroscopic exposure time.

  11. Fast skin dose estimation system for interventional radiology.

    Science.gov (United States)

    Takata, Takeshi; Kotoku, Jun'ichi; Maejima, Hideyuki; Kumagai, Shinobu; Arai, Norikazu; Kobayashi, Takenori; Shiraishi, Kenshiro; Yamamoto, Masayoshi; Kondo, Hiroshi; Furui, Shigeru

    2018-03-01

    To minimise the radiation dermatitis related to interventional radiology (IR), rapid and accurate dose estimation has been sought for all procedures. We propose a technique for estimating the patient skin dose rapidly and accurately using Monte Carlo (MC) simulation with a graphical processing unit (GPU, GTX 1080; Nvidia Corp.). The skin dose distribution is simulated based on an individual patient's computed tomography (CT) dataset for fluoroscopic conditions after the CT dataset has been segmented into air, water and bone based on pixel values. The skin is assumed to be one layer at the outer surface of the body. Fluoroscopic conditions are obtained from a log file of a fluoroscopic examination. Estimating the absorbed skin dose distribution requires calibration of the dose simulated by our system. For this purpose, a linear function was used to approximate the relation between the simulated dose and the measured dose using radiophotoluminescence (RPL) glass dosimeters in a water-equivalent phantom. Differences of maximum skin dose between our system and the Particle and Heavy Ion Transport code System (PHITS) were as high as 6.1%. The relative statistical error (2 σ) for the simulated dose obtained using our system was ≤3.5%. Using a GPU, the simulation on the chest CT dataset aiming at the heart was within 3.49 s on average: the GPU is 122 times faster than a CPU (Core i7-7700K; Intel Corp.). Our system (using the GPU, the log file, and the CT dataset) estimated the skin dose more rapidly and more accurately than conventional methods.

  12. Stochastic risk estimation from medical x-ray diagnostic examinations, 2. Risk estimates of individuals from x-ray diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Hashizume, T; Maruyama, T; Noda, Y; Iwai, K; Tateno, Y [National Inst. of Radiological Sciences, Chiba (Japan); Nishizawa, K

    1981-01-01

    The risks of genetic, leukemia and malignant diseases from medical X-ray diagnostic examinations were estimated using the frequency of radiographic and fluoroscopic exposures per diagnostic examination, child expectancy, leukemia and malignancy significant factors, and using a weighting factor determined on the basis of data concerning the cancer mortality among atomic bomb survivors in Nagasaki and of a recommendation of International Commission of Radiological Protection. The organ or tissue doses with respect to the stochastic risks were determined with ionization chambers and thermoluminescent dosimeters placed at the positions of the organs or tissues in a RANDO woman phantom which was exposed to diagnostic X-rays according to technical factors of typical radiographic and fluoroscopic examinations obtained from a nationwide survey. The resultant risks by age-group and type of radiographic and fluoroscopic examination are tabulated in terms of risk level of 10/sup -6/. In general, the total risk defined as the sum of genetic, leukemia and malignant risks was a high value for the X-ray diagnosis of digestive organs involving barium meal and barium enema. For example, the total risk for young age-group was 100 to 200 x 10/sup -6/ for the X-ray diagnosis of digestive organs. The total risk from the chest radiography was lower value as compared with the risk from the X-ray diagnosis of other organs or tissues. On the contrary, the risk from the chest tomography was comparable to the risk from the diagnosis of digestive organs. The total risk decreased with increasing of age for every X-ray diagnostic examination.

  13. Skeletal imaging following reconstruction of the posterior cruciate ligament: in vivo comparison of fluoroscopy, radiography, and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Osti, Michael; Benedetto, Karl Peter [Academic Hospital Feldkirch, Department for Trauma Surgery and Sports Traumatology, Feldkirch (Austria); Krawinkel, Alessa [Academic Hospital Feldkirch, Department for Radiology, Feldkirch (Austria)

    2014-12-15

    Intra- and postoperative validation of anatomic footprint replication in posterior cruciate ligament (PCL) reconstruction can be conducted using fluoroscopy, radiography, or computed tomography (CT) scans. However, effectiveness and exposure to radiation of these imaging modalities are unknown. The objective of this study was to evaluate the comparative effectiveness of fluoroscopy, radiography, and CT in detecting femoral and tibial tunnel positions following an all-inside reconstruction of the PCL ligament in vivo. The study design was a retrospective case series. Intraoperative fluoroscopic images, postoperative radiographs, and CT scans were obtained in 50 consecutive patients following single-bundle PCL reconstruction. The centers of the tibial and femoral tunnel apertures were identified and correlated to measurement grid systems. The results of fluoroscopic, radiographic, and CT measurements were compared to each other and accumulated radiation dosages were calculated. Comparing the imaging groups, no statistically significant difference could be detected for the reference of the femoral tunnel to the intercondylar depth and height, for the reference of the tibial tunnel to the mediolateral diameter of the tibial plateau and for the superoinferior distance of the tibial tunnel entry to the tibial plateau and to the former physis line. Effective doses resulting from fluoroscopic, radiographic, and CT exposure averaged 2.9 mSv, standard deviation (±SD) 4.1 mSv, to 1.3 ± 0.8 mSv and to 3.6 ± 1.0 mSv, respectively. Fluoroscopy, radiography, and CT yield approximately equal effectiveness in detecting parameters used for quality validation intra- and postoperatively. An accumulating exposure to radiation must be considered. (orig.)

  14. The lung volume reduction coil for the treatment of emphysema : a new therapy in development

    NARCIS (Netherlands)

    Klooster, Karin; ten Hacken, Nick H. T.; Slebos, Dirk-Jan

    Lung volume reduction (LVR) coil treatment is a novel therapy for patients with severe emphysema. In this bilateral bronchoscopic treatment, approximately 10 LVR coils per lobe are delivered under fluoroscopic guidance in two sequential procedures. The LVR coil reduces lung volume by compressing the

  15. Analytical guide wire motion algorithm for simulation of endovascular interventions

    NARCIS (Netherlands)

    Konings, M. K.; van de Kraats, E. B.; Alderliesten, T.; Niessen, W. J.

    2003-01-01

    Performing minimally invasive vascular interventions requires proper training, as a guide wire needs to be manipulated, by the tail, under fluoroscopic guidance. To provide a training environment, the motion of the guide wire inside the human vasculature can be simulated by computer. Such a

  16. The use of virtual reality for training in carotid artery stenting: a construct validation study

    DEFF Research Database (Denmark)

    Berry, M.; Reznick, R.; Lystig, T.

    2008-01-01

    difference in video-gaming habits was demonstrated. Conclusion: With the exception of the metrics of performance time and fluoroscopic use, construct validity of the Procedicus-VIST carotid metrics were not confirmed. Virtual reality simulation as a training method was valued more by novices than...

  17. Ultrasound Guided Percutaneous Nephrostomy: Experience at ...

    African Journals Online (AJOL)

    Background: Obstructive uropathy is a common problem in urologic practice; temporary relief of obstruction in the upper tract poses a significant challenge. Ultrasound‑guided percutaneous nephrostomy (PCN) is an option for upper tract drainage; compared to fluoroscopic guidance, it is readily available, affordable, and not ...

  18. Removal of non-deflatable retained foley catheter in the bladder by percutaneous puncture of catheter balloon

    International Nuclear Information System (INIS)

    Yoo, Jae Duk; Kim, Jae Kyu; Park, Jin Gyun; Chung, Hyon De

    1988-01-01

    Nondeflatable Foley catheter in the bladder is an uncommon event. We recently experienced a patient in whom the urologist were unable to remove a Foley catheter with cystoscope due to public bone fractures. The procedure, which was successfully carried out, consists of puncturing the ballon under fluoroscope.

  19. Navigatiechirurgie en fractuurbehandeling

    NARCIS (Netherlands)

    Schep, N. W. L.; van Vugt, A. B.

    2006-01-01

    During operative fracture treatment the surgeon depends on fluoroscopic or X-ray radiological images as well as CT scans or MRI scans. This means that the surgeon sees only images at a given moment. Continuous imaging is technically complex and is accompanied by considerable exposure to radiation.

  20. [Navigation surgery and fracture treatment

    NARCIS (Netherlands)

    Schep, N.W.; Vugt, A.B. van

    2006-01-01

    During operative fracture treatment the surgeon depends on fluoroscopic or X-ray radiological images as well as CT scans or MRI scans. This means that the surgeon sees only images at a given moment. Continuous imaging is technically complex and is accompanied by considerable exposure to radiation.

  1. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    International Nuclear Information System (INIS)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook

    1995-01-01

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy

  2. Radiation doses in interventional neuroradiology

    International Nuclear Information System (INIS)

    Theodorakou, C.; Butler, P.; Horrocks, J.A.

    2001-01-01

    Patient radiation doses during interventional radiology (IR) procedures may reach the thresholds for radiation-induced skin and eye lens injuries. This study investigates the radiation doses received by patients undergoing cerebral embolization. Measurements were conducted using thermoluminescent dosimeters. Radiotherapy verification films were used in order to visualise the radiation field. For each procedure the fluoroscopic and digital dose-area product, the fluoroscopic time, the total number of acquired images and entrance-skin dose calculated by the angiographic unit were recorded. In this paper, the skin, eye and thyroid glands doses on a sample of patients are presented. From a preliminary study of 13 patients having undergone cerebral embolization, it was deduced that six of them have received a dose above 1 Gy. Detailed dose data from patients undergoing IR procedures will be collected in the future with the aim of developing a model to allow estimation of the dose prior to the procedure as well as to look at techniques of dose reduction. (author)

  3. Diaphragmatic hernia repair using a rectus abdominis muscle pedicle flap in three dogs.

    Science.gov (United States)

    Chantawong, P; Komin, K; Banlunara, W; Kalpravidh, M

    2013-01-01

    To report the clinical use of a pedicle flap from the rectus abdominis muscle to repair extensive diaphragmatic tears in dogs with diaphragmatic hernia. Three dogs with a combination of radial and circumferential diaphragmatic tears were studied. The circumferential tear was repaired by suturing the wound edge with the edge at the abdominal wall. A pedicle flap of the rectus abdominis muscle was used for repairing the radial tear. The dogs were examined radiographically for lung and diaphragm appearance and evidence of reherniation at 10 days, and at one, two, and four months after surgery, and fluoroscopically for paradoxical motion of the diaphragm at one and four months. The rectus abdominis muscle pedicle flap was successfully used in all three dogs. The animals recovered uneventfully without evidence of reherniation during the four follow-up months. Fluoroscopic examination revealed no paradoxical motion of the diaphragm. A rectus abdominis muscle pedicle flap can be used for repairing large diaphragmatic defects in dogs.

  4. The establishment of local diagnostic reference levels in endoscopic retrograde cholangiopancreatography: a practical tool for the optimisation and for quality assurance management

    International Nuclear Information System (INIS)

    Saukko, E.; Henner, A.; Nieminen, M.T.; Ahonen, S.-M.

    2017-01-01

    Fluoroscopic procedures are an area of special concern in relation to radiation protection. The aim of this study was to describe the current level of patient radiation doses in endoscopic retrograde cholangiopancreatography (ERCP) collected from a single centre, as well as to establish and review local diagnostic reference levels (DRLs) in ERCP. A total of 100 patients' radiation doses in ERCP were recorded, and the third-quartile method was adopted to establish local DRLs for ERCP. The mean dose area product (DAP) was 2.05 Gy cm 2 , fluoroscopy time (FT) 1.7 min and the number of images was 3. The proposed local DRLs for ERCP were 3.00 Gy cm 2 and 3.0 min. Local DRLs were reviewed in a sample of 25 patients 5 y after they had been established. In reviewing data, the averages of DAP and FT were below the local DRLs. Local DRLs help in the optimisation process of fluoroscopic procedures and guides to a good clinical practice. (authors)

  5. A practical laboratory study simulating the percutaneous lumbar transforaminal epidural injection: training model in fresh cadaveric sheep spine.

    Science.gov (United States)

    Suslu, Husnu

    2012-01-01

    Laboratory training models are essential for developing and refining treatment skills before the clinical application of surgical and invasive procedures. A simple simulation model is needed for young trainees to learn how to handle instruments, and to perform safe lumbar transforaminal epidural injections. Our aim is to present a model of a fresh cadaveric sheep lumbar spine that simulates the lumbar transforaminal epidural injection. The material consists of a 2-year-old fresh cadaveric sheep spine. A 4-step approach was designed for lumbar transforaminal epidural injection under C-arm scopy. For the lumbar transforaminal epidural injection, the fluoroscope was adjusted to get a proper oblique view while the material was stabilized in a prone position. The procedure then begin, using the C-arm guidance scopy. The model simulates well the steps of standard lumbar transforaminal epidural injections in the human spine. The cadaveric sheep spine represents a good method for training and it simulates fluoroscopic lumbar transforaminal epidural steroid injection procedures performed in the human spine.

  6. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy.

  7. Improvement of observer performance during fluoroscopy by local adaptive contrast enhancement

    International Nuclear Information System (INIS)

    Gould, R.G.; Demas, B.E.; Maroney, T.P.

    1988-01-01

    The ability of a video processor (FluoroVision FV-1), which performs two-dimensional locally adaptive contrast enhancement, to improve the detection of a low-contrast object was evaluated by means of receiver operating characteristic (ROC) curves. Three independent observers viewed a videotape of 50 fluoroscopic images of a varied background, in which a test object was present in 25. Each observer viewed the tape under four conditions: (1) no processing, (2) temporal noise reduction (gaussian weighted time averaging, (3) contrast enhancement, and (4) both noise reduction and contrast enhancement. The results were that detection was significantly improved by the locally adaptive contrast enhancement. Noise reduction did not significantly improve performance, probably because washer detection was limited by background contrast variations as well as noise and because only a small amount of noise reduction was used. The authors conclude that the processing device is potentially valuable in improving the quality of clinical fluoroscopic images

  8. The clinical value of the special functions of DSA in interventional embolization for uterine fibroids

    International Nuclear Information System (INIS)

    He Yushen; Lu Dong; Lv Weifu; Zhang Jingsong

    2009-01-01

    Objective: To evaluate the special functions of DSA in interventional embolization therapy for uterine fibroids. Methods: The special functions of DSA, including 3D-DSA, the optimal working position and road-mapping technique, were utilized in performing interventional embolization therapy for uterine fibroids in twenty-six cases (experimental group). Routine DSA angiography was employed in twenty cases(control group). The volume of contrast media used, the time of completing the interventional procedure and the total fluoroscopic time in two groups were compared and the results were analyzed. Results: The difference in the volume of contrast agent used and in the total fluoroscopic time between two groups was statistically significant (P 0.05). Conclusion: In treating uterine fibroids with interventional embolization, the use of the special functions of DSA can reduce the manipulation time and lower the operation risk. Moreover, the technique of visible 3D reconstruction image is of great significance in guiding the procedure. (authors)

  9. Radiation Ordinance 1983 (No. 58 of 1983) (Australian Capital Territory)

    International Nuclear Information System (INIS)

    1983-01-01

    This Ordinance provides for the safe use, transportation and disposal of radioactive materials and irradiating apparatus. It repeals the Fluoroscopes Ordinance of 1958. Radioactive materials whose radioactivity does not exceed levels as set out in a Schedule to the Ordinance are exempted from application of the Ordinance. (NEA) [fr

  10. etude et fabrication de la toupie electonique pour la verification du ...

    African Journals Online (AJOL)

    Houessouvo

    The tool allows to sensitize the hospital on the importance of checking the exposure time.This study thus contributes indirectly to quality health care by improving the quality of radiographic and fluoroscopic picture. This tool will also help to ensure proper maintenance at optimum cost of medical radiography equipment.

  11. Torsional Dynamics of Steerable Needles: Modeling and Fluoroscopic Guidance

    Science.gov (United States)

    Swensen, John P.; Lin, MingDe; Okamura, Allison M.; Cowan, Noah J.

    2017-01-01

    Needle insertions underlie a diversity of medical interventions. Steerable needles provide a means by which to enhance existing needle-based interventions and facilitate new ones. Tip-steerable needles follow a curved path and can be steered by twisting the needle base during insertion, but this twisting excites torsional dynamics that introduce a discrepancy between the base and tip twist angles. Here, we model the torsional dynamics of a flexible rod—such as a tip-steerable needle—during subsurface insertion and develop a new controller based on the model. The torsional model incorporates time-varying mode shapes to capture the changing boundary conditions inherent during insertion. Numerical simulations and physical experiments using two distinct setups—stereo camera feedback in semi-transparent artificial tissue and feedback control with real-time X-ray imaging in optically opaque artificial tissue— demonstrate the need to account for torsional dynamics in control of the needle tip. PMID:24860026

  12. Fluoroscopically guided pyeloureteral interventions using a retrograde perurethral approach

    International Nuclear Information System (INIS)

    Amendola, M.A.; Banner, M.P.; Pollack, H.M.; Gordon, R.L.; Van Arsdalen, K.N.

    1987-01-01

    Employing standard interventional equipment, fluoroscopy, and partially or completely inserted ureteral catheters for access, the authors performed 168 perurethral interventional procedures since 1985. Procedures have included insertion of double (n = 42) or single pigtail stents (n = 47), advancement of retrograde ureteral catheters with or without displacement of a ureteral stone to the renal pelvis (n = 42), urothelial biopsy (n = 30), balloon dilation of ureteral structures (n = 3), ureteral stone extraction (n = 1), and conversion of retrograde to antegrade catheters for balloon dilation of ureteropelvic junction strictures (n = 3). This retrograde approach often obviates the need for antegrade interventional procedures (including percutaneous nephrostomy and ureteral stenting), ureteroscopy, or surgery. Indications, techniques, pitfalls, and complications are illustrated

  13. Study on metallization on RX tubes of fluoroscopic equipment

    International Nuclear Information System (INIS)

    Ramos Caballero, L. J.; Angulo Pain, E.; Iborra Oquendo, M. a.; Seguro Fernandez, A.

    2013-01-01

    The PECCRD sets values for the performance of a team of rays x as a function of the total filtration of this (for 80 KV, a total filtration [2.5, 5] mm's to the). However it is recommended to check if the RX tube had metallization by exhaustion (part of anode tungsten evaporates and lining the inside of the envelope of the tube). This effect produces an increase in filtration tube and a decrease in performance. (Author)

  14. CIRSE Standards of Practice Guidelines on Gastrostomy

    Energy Technology Data Exchange (ETDEWEB)

    Sutcliffe, James, E-mail: jasutcliffe@gmail.com; Wigham, Andrew, E-mail: a.wigham@doctors.org.uk [Oxford University Hospitals NHS Trust, Radiology Department (United Kingdom); Mceniff, Niall, E-mail: nmceniff@stjames.ie [St. James’s Hospital, Radiology (DiagIm) (Ireland); Dvorak, Petr, E-mail: petr-dvorak@email.cz [Faculty Hospital Charles University, Radiology Department (Czech Republic); Crocetti, Laura, E-mail: laura.crocetti@med.unipi.it [University of Pisa, Diagnostic Imaging and Intervention, Department of Hepatology and Liver Transplants (Italy); Uberoi, Raman, E-mail: Raman.Uberoi@ouh.nhs.uk [Oxford University Hospitals NHS Trust, Radiology Department (United Kingdom)

    2016-07-15

    PurposeSurgical Gastrostomy has been around since the 19th century but in 1980 the first successful percutaneous endoscopic gastrostomy was reported. A year later the first successful percutaneous gastrostomy was performed using fluoroscopic guidance. The technique for percutaneous insertion and the equipment used has been refined since then and it is now considered the gold standard for gastrostomy insertion. Here we present guidelines for image-guided enteral feeding tubes in adults.Material and MethodWe performed a review and analysis of the scientific literature, other national and international guidelines and expert opinion.ResultsStudies have shown fluoroscopic techniques have consistently higher success rates with lower rates of major complications than endoscopic techniques. However, the Achilles' heel of many fluoroscopic techniques is the requirement for smaller gastrostomy tube sizes resulting in them being more prone to blockages and thus requiring further intervention.ConclusionRadiological feeding tube insertion is a safe and effective procedure. Success rates are higher, and complication rates lower than PEG or surgical gastrostomy tube placement and innovative techniques for gastric and jejunal access mean that there are very few cases in which RIG is not possible. The principal weakness of radiologically inserted gastrostomies is the limitiation on tube size which leads to a higher rate of tube blockage. Per-oral image-guided gastrostomies have to an extent addressed this but have not been popularised. Currently many centres still consider endoscopic gastrostomies as the first line unless patients are too unwell to undergo this procedure or previous attempts have failed, in which case radioloically inserted gastrostomies are the technique of choice.

  15. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C. [University Hospital of Wuerzburg (Germany). Inst. of Diagnostic and Interventional Radiology

    2015-07-15

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm{sup 2}) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  16. Markerless gating for lung cancer radiotherapy based on machine learning techniques

    International Nuclear Information System (INIS)

    Lin Tong; Li Ruijiang; Tang Xiaoli; Jiang, Steve B; Dy, Jennifer G

    2009-01-01

    In lung cancer radiotherapy, radiation to a mobile target can be delivered by respiratory gating, for which we need to know whether the target is inside or outside a predefined gating window at any time point during the treatment. This can be achieved by tracking one or more fiducial markers implanted inside or near the target, either fluoroscopically or electromagnetically. However, the clinical implementation of marker tracking is limited for lung cancer radiotherapy mainly due to the risk of pneumothorax. Therefore, gating without implanted fiducial markers is a promising clinical direction. We have developed several template-matching methods for fluoroscopic marker-less gating. Recently, we have modeled the gating problem as a binary pattern classification problem, in which principal component analysis (PCA) and support vector machine (SVM) are combined to perform the classification task. Following the same framework, we investigated different combinations of dimensionality reduction techniques (PCA and four nonlinear manifold learning methods) and two machine learning classification methods (artificial neural networks-ANN and SVM). Performance was evaluated on ten fluoroscopic image sequences of nine lung cancer patients. We found that among all combinations of dimensionality reduction techniques and classification methods, PCA combined with either ANN or SVM achieved a better performance than the other nonlinear manifold learning methods. ANN when combined with PCA achieves a better performance than SVM in terms of classification accuracy and recall rate, although the target coverage is similar for the two classification methods. Furthermore, the running time for both ANN and SVM with PCA is within tolerance for real-time applications. Overall, ANN combined with PCA is a better candidate than other combinations we investigated in this work for real-time gated radiotherapy.

  17. C-arm cone-beam CT combined with a new electromagnetic navigation system for guidance of percutaneous needle biopsies. Initial clinical experience

    International Nuclear Information System (INIS)

    Kickuth, R.; Reichling, C.; Bley, T.; Hahn, D.; Ritter, C.

    2015-01-01

    To evaluate the feasibility and efficacy of C-arm fluoroscopic cone-beam computed tomography (CACT) in combination with a new electromagnetic tracking (EMT) system for needle guidance during percutaneous biopsies. 53 patients were referred for biopsy of thoracic (n = 19) and abdominal (n = 34) lesions. CT-like images of the anatomical region of interest (ROI) were generated using a flat panel-based angiographic system. These images were transmitted to an EMT system. A coaxial puncture needle with a sensor in its tip was connected with the navigation system and tracked into an electromagnetic field created via a field generator. Data generated within this field were merged with the CACT images. On a monitor both the anatomical ROI and needle tip position were displayed to enable precise needle insertion into the target. Through the coaxial needle, biopsy specimens for the histologic evaluation were extracted. Number of representative biopsy samples, number of core biopsies/patient, total procedure time, dose-area product, fluoroscopic time, and complications were recorded. 53 CACT/EMT-guided biopsy procedures were performed, 48 of which (91 %) yielded representative tissue samples. Four core biopsies were obtained from each patient. 40 (75 %) lesions were malignant and 13 (25 %) lesions were benign. The total procedure time was 9 ± 5 min (range, 3 - 23 min), fluoroscopic time was 0.8 ± 0.4 min (range, 0.4 - 2 min). The mean dose-area product (cGy cm 2 ) was 7373 (range, 895 - 26 904). The rate of complications (1 pneumothorax, 2 hemoptyses) was 6 %. CACT combined with EMT appears to be a feasible and effective technique for the guidance of percutaneous biopsies with a low rate of therapeutically relevant complications.

  18. Medical radiation safety in the angiography room

    International Nuclear Information System (INIS)

    Kudou, Tamaki

    2011-01-01

    Author's efforts for angiographic procedure and technique aiming to reduce patient's exposure are described on a case with radiation skin hazard and on considerations of regulations and investigations. The case is a male patient (45 years old at the first intracardiac catheter examination, stature 164 cm, body wt. 116 kg), who, due to the diagnosis of angina pectoris and cardiac infarction, has the 5-year history of 5 coronary angiography (CAG), 6 percutaneous coronary intervention (PCI) and 1 off-pump coronary arterial bypass grafting (CABG). Because of serious skin injury and pain development after later PCI (172.2 min) (Oct. 2006) and their exacerbation after the latest PCI (27.1 min) (Apr. 2007), skin transplantation is conducted (Nov.). The exposure dose at the later PCI above is estimated to be around 12 Gy. Based on the case, consideration is made on regulatory recommendations by FDA, IAEA, ICRP, and investigational results of fluoroscopic mode vs dose by members of Japanese Circulatory Technology. With those references where the fluoroscopy at 20 mGy/min is assumed, the dose 12 Gy estimated above is thought to be resulted from the fluoroscopic dose >50 mGy/min within about 4 hr. To reduce the exposure, the author gives 11 items to be noted in interventional radiology: short fluoroscopic time, low rate pulse, minimal acquisition, use of additional filter, dose optimization, long distance between focus and skin, short distance between image intensifier (I.I.) and/or flat panel detector (FPD), minimal field, to avoid the excess inch-up, continuous maintenance of equipment, and record/preservation of the dose indicated by the machine. (T.T.)

  19. Radiographic landmarks for locating the femoral origin of the superficial medial collateral ligament.

    Science.gov (United States)

    Hartshorn, Timothy; Otarodifard, Karimdad; White, Eric A; Hatch, George F Rick

    2013-11-01

    Little has been written about the use of radiographic landmarks for locating the origin of the superficial medial collateral ligament (sMCL). A standardized radiographic landmark for the sMCL origin using intraoperative fluoroscopic imaging may be of value in aiding the surgeon in accurate femoral tunnel placement in the setting of extensive soft tissue disruption and bony attrition. To determine a reproducible radiographic landmark that will assist in correct femoral tunnel placement in sMCL repair and reconstruction. Descriptive laboratory study. Ten fresh-frozen unmatched human cadaveric knees were dissected, and the origin of the sMCL was exposed. A 2-mm metallic marker was then placed at the center of the femoral origin of the sMCL. True lateral fluoroscopically assisted digital radiographs were obtained of the knee with the posterior and distal femoral condyles overlapping in a standardized fashion. With the use of computer software, reference lines were drawn on the images, creating 4 quadrants. Two independent examiners performed quantitative measurements of the sMCL origin in relation to this axis and to the Blumensaat line. Mean measurements showed the sMCL origin to be closely related to the intersection point of the Blumensaat line and a line drawn distally from the posterior femoral cortex on a true lateral radiograph. The sMCL origin was found at a mean point 1.6 ± 4.3 mm posterior and 4.9 ± 2.1 mm proximal to the intersection of a line paralleling the posterior femoral cortex and a line drawn perpendicular to the posterior femoral cortical line, where it intersects the Blumensaat line. In 5 of 10 specimens, the center of the sMCL origin fell precisely on the Blumensaat line. The remaining specimens had sMCL origins anterior to the Blumensaat line. The femoral origin of the sMCL was found in the proximal and posterior quadrants in 8 of 10 specimens. With a relatively small amount of deviation, the sMCL origin can be consistently identified on a true

  20. Principal component reconstruction (PCR) for cine CBCT with motion learning from 2D fluoroscopy.

    Science.gov (United States)

    Gao, Hao; Zhang, Yawei; Ren, Lei; Yin, Fang-Fang

    2018-01-01

    This work aims to generate cine CT images (i.e., 4D images with high-temporal resolution) based on a novel principal component reconstruction (PCR) technique with motion learning from 2D fluoroscopic training images. In the proposed PCR method, the matrix factorization is utilized as an explicit low-rank regularization of 4D images that are represented as a product of spatial principal components and temporal motion coefficients. The key hypothesis of PCR is that temporal coefficients from 4D images can be reasonably approximated by temporal coefficients learned from 2D fluoroscopic training projections. For this purpose, we can acquire fluoroscopic training projections for a few breathing periods at fixed gantry angles that are free from geometric distortion due to gantry rotation, that is, fluoroscopy-based motion learning. Such training projections can provide an effective characterization of the breathing motion. The temporal coefficients can be extracted from these training projections and used as priors for PCR, even though principal components from training projections are certainly not the same for these 4D images to be reconstructed. For this purpose, training data are synchronized with reconstruction data using identical real-time breathing position intervals for projection binning. In terms of image reconstruction, with a priori temporal coefficients, the data fidelity for PCR changes from nonlinear to linear, and consequently, the PCR method is robust and can be solved efficiently. PCR is formulated as a convex optimization problem with the sum of linear data fidelity with respect to spatial principal components and spatiotemporal total variation regularization imposed on 4D image phases. The solution algorithm of PCR is developed based on alternating direction method of multipliers. The implementation is fully parallelized on GPU with NVIDIA CUDA toolbox and each reconstruction takes about a few minutes. The proposed PCR method is validated and

  1. New electronic filtering technique in digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Stacul, F; Pozzi-Mucelli, R; Predonzan, F; Magnaldi, S; Godina, G

    1986-01-01

    The authors report their experience with a new electronic filtering technique in digital subtraction angiography (DSA). The principles of the technique are reported and the advantages in comparison with conventional filters are stressed (accurate and fast placement without fluoroscopic exposure). The system provided excellent results in about 900 DSA examinations.

  2. Sharp foreign body ingestion by a young girl

    African Journals Online (AJOL)

    Riyadh Mohamad Hasan

    2017-06-09

    Jun 9, 2017 ... Sharp foreign body ingestion by a young girl. Riyadh Mohamad Hasan. University of Baghdad ... ray imaging and retrieved with the aid of C-arm fluoroscope at a laparotomy. Her postoperative period ... In our patient the foreign bodies were long sharp ones (sewing needles). Foreign body ingestion can be ...

  3. Effectiveness of Stellate Ganglion Block Under Fuoroscopy or Ultrasound Guidance in Upper Extremity CRPS.

    Science.gov (United States)

    Imani, Farnad; Hemati, Karim; Rahimzadeh, Poupak; Kazemi, Mohamad Reza; Hejazian, Kokab

    2016-01-01

    Stellate Ganglion Block (SGB) is an effective technique which may be used to manage upper extremities pain due to Chronic Regional Pain Syndrome (CRPS), in this study we tried to evaluate the effectiveness of this procedure under two different guidance for management of this syndrome. The purpose of this study was to evaluate the effectiveness of ultrsound guide SGB by comparing it with the furoscopy guided SGB in upper extermities CRPS patients in reducing pain & dysfuction of the affected link. Fourteen patients with sympathetic CRPS in upper extremities in a randomized method with block randomization divided in two equal groups (with ultrasound or fluoroscopic guidance). First group was blocked under fluoroscopic guidance and second group blocked under ultrasound guidance. After correct positioning of the needle, a mixture of 5 ml bupivacaine 0.25% and 1 mL of triamcinolone was injected. These data represent no meaningful statistical difference between the two groups in terms of the number of pain attacks before the blocks, a borderline correlation between two groups one week and one month after the block and a significant statistical correlation between two groups three month after the block. These data represent no meaningful statistical difference between the patients of any group in terms of the pain intensity (from one week to six months after block), p-value = 0.61. These data represent a meaningful statistical difference among patients of any group and between the two groups in terms of the pain intensity (before the block until six months after block), p-values were 0.001, 0.031 respectively. According the above mentioned data, in comparison with fluoroscopic guidance, stellate ganglion block under ultrasound guidance is a safe and effective method with lower complication and better improvement in patient's disability indexes.

  4. SU-E-I-58: Experiences in Setting Up An Online Fluoroscopy Tracking System in a Large Healthcare System

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, R; Wunderle, K; Lingenfelter, M [The Cleveland Clinic, Cleveland, OH (United States)

    2015-06-15

    Purpose: Transitioning from a paper based to an online system for tracking fluoroscopic case information required by state regulation and to conform to NCRP patient dose tracking suggestions. Methods: State regulations require documentation of operator, equipment, and some metric of tube output for fluoroscopy exams. This information was previously collected in paper logs, which was cumbersome and inefficient for the large number of fluoroscopic units across multiple locations within the system. The “tech notes” feature within Siemens’ Syngo workflow RIS was utilized to create an entry form for technologists to input case information, which was sent to a third party vendor for archiving and display though an online web based portal. Results: Over 55k cases were logged in the first year of implementation, with approximately 6,500 cases per month once fully online. A system was built for area managers to oversee and correct data, which has increased the accuracy of inputted values. A high-dose report was built to automatically send notifications when patients exceed trigger levels. In addition to meeting regulatory requirements, the new system allows for larger scale QC in fluoroscopic cases by allowing comparison of data from specific procedures, locations, equipment, and operators so that instances that fall outside of reference levels can be identified for further evaluation. The system has also drastically improved identification of operators without documented equipment specific training. Conclusion: The transition to online fluoroscopy logs has improved efficiency in meeting state regulatory requirements as well as allowed for identification of particular procedures, equipment, and operators in need of additional attention in order to optimize patient and personnel doses, while high dose alerts improve patient care and follow up. Future efforts are focused on incorporating case information from outside of radiology, as well as on automating processes for

  5. SU-E-I-58: Experiences in Setting Up An Online Fluoroscopy Tracking System in a Large Healthcare System

    International Nuclear Information System (INIS)

    Fisher, R; Wunderle, K; Lingenfelter, M

    2015-01-01

    Purpose: Transitioning from a paper based to an online system for tracking fluoroscopic case information required by state regulation and to conform to NCRP patient dose tracking suggestions. Methods: State regulations require documentation of operator, equipment, and some metric of tube output for fluoroscopy exams. This information was previously collected in paper logs, which was cumbersome and inefficient for the large number of fluoroscopic units across multiple locations within the system. The “tech notes” feature within Siemens’ Syngo workflow RIS was utilized to create an entry form for technologists to input case information, which was sent to a third party vendor for archiving and display though an online web based portal. Results: Over 55k cases were logged in the first year of implementation, with approximately 6,500 cases per month once fully online. A system was built for area managers to oversee and correct data, which has increased the accuracy of inputted values. A high-dose report was built to automatically send notifications when patients exceed trigger levels. In addition to meeting regulatory requirements, the new system allows for larger scale QC in fluoroscopic cases by allowing comparison of data from specific procedures, locations, equipment, and operators so that instances that fall outside of reference levels can be identified for further evaluation. The system has also drastically improved identification of operators without documented equipment specific training. Conclusion: The transition to online fluoroscopy logs has improved efficiency in meeting state regulatory requirements as well as allowed for identification of particular procedures, equipment, and operators in need of additional attention in order to optimize patient and personnel doses, while high dose alerts improve patient care and follow up. Future efforts are focused on incorporating case information from outside of radiology, as well as on automating processes for

  6. Pediatric interventional radiography equipment: safety considerations

    International Nuclear Information System (INIS)

    Strauss, Keith J.

    2006-01-01

    This paper discusses pediatric image quality and radiation dose considerations in state-of-the-art fluoroscopic imaging equipment. Although most fluoroscopes are capable of automatically providing good image quality on infants, toddlers, and small children, excessive radiation dose levels can result from design deficiencies of the imaging device or inappropriate configuration of the equipment's capabilities when imaging small body parts. Important design features and setup choices at installation and during the clinical use of the imaging device can improve image quality and reduce radiation exposure levels in pediatric patients. Pediatric radiologists and cardiologists, with the help of medical physicists, need to understand the issues involved in creating good image quality at reasonable pediatric patient doses. The control of radiographic technique factors by the generator of the imaging device must provide a large dynamic range of mAs values per exposure pulse during both fluoroscopy and image recording as a function of patient girth, which is the thickness of the patient in the posterior-anterior projection at the umbilicus (less than 10 cm to greater than 30 cm). The range of pulse widths must be limited to less than 10 ms in children to properly freeze patient motion. Variable rate pulsed fluoroscopy can be leveraged to reduce radiation dose to the patient and improve image quality. Three focal spots with nominal sizes of 0.3 mm to 1 mm are necessary on the pediatric unit. A second, lateral imaging plane might be necessary because of the child's limited tolerance of contrast medium. Spectral and spatial beam shaping can improve image quality while reducing the radiation dose. Finally, the level of entrance exposure to the image receptor of the fluoroscope as a function of operator choices, of added filter thickness, of selected pulse rate, of the selected field-of-view and of the patient girth all must be addressed at installation. (orig.)

  7. Real-time monitoring and verification of in vivo high dose rate brachytherapy using a pinhole camera

    International Nuclear Information System (INIS)

    Duan, Jun; Macey, Daniel J.; Pareek, Prem N.; Brezovich, Ivan A.

    2001-01-01

    We investigated a pinhole imaging system for independent in vivo monitoring and verification of high dose rate (HDR) brachytherapy treatment. The system consists of a high-resolution pinhole collimator, an x-ray fluoroscope, and a standard radiographic screen-film combination. Autofluoroscopy provides real-time images of the in vivo Ir-192 HDR source for monitoring the source location and movement, whereas autoradiography generates a permanent record of source positions on film. Dual-pinhole autoradiographs render stereo-shifted source images that can be used to reconstruct the source dwell positions in three dimensions. The dynamic range and spatial resolution of the system were studied with a polystyrene phantom using a range of source strengths and dwell times. For the range of source activity used in HDR brachytherapy, a 0.5 mm diameter pinhole produced sharp fluoroscopic images of the source within the dynamic range of the fluoroscope. With a source-to-film distance of 35 cm and a 400 speed screen-film combination, the same pinhole yielded well recognizable images of a 281.2 GBq (7.60 Ci) Ir-192 source for dwell times in the typical clinical range of 2 to 400 s. This 0.5 mm diameter pinhole could clearly resolve source positions separated by lateral displacements as small as 1 mm. Using a simple reconstruction algorithm, dwell positions in a phantom were derived from stereo-shifted dual-pinhole images and compared to the known positions. The agreement was better than 1 mm. A preliminary study of a patient undergoing HDR treatment for cervical cancer suggests that the imaging method is clinically feasible. Based on these studies we believe that the pinhole imaging method is capable of providing independent and reliable real-time monitoring and verification for HDR brachytherapy

  8. Comparative analysis of anterior and posterior contrast injection approaches for shoulder MR arthrograms in adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Gupton, Theodore B.; Cahill, Anne M. [The Children' s Hospital of Philadelphia, Division of Interventional Radiology, Department of Radiology, Philadelphia, PA (United States); Delgado, Jorge [The Children' s Hospital of Philadelphia, Department of Radiology, Philadelphia, PA (United States); Jaramillo, Diego [Stanford University Medical Center, Diagnostic Radiology, Palo Alto, CA (United States); Chauvin, Nancy A. [The Children' s Hospital of Philadelphia, Perelman School of Medicine at the University of Pennsylvania, Musculoskeletal Imaging, Department of Radiology, Philadelphia, PA (United States)

    2016-12-15

    There is no consensus in the literature concerning the optimal approach for performing a fluoroscopically guided shoulder arthrogram injection in a pediatric population. To compare adequacy of capsular injection and radiation doses between fluoroscopically guided anterior and posterior glenohumeral joint contrast injections in adolescents. We evaluated imaging in 67 adolescents (39 boys, 28 girls; mean age 16.0 years; range 11.7-19.1 years) who underwent an anterior approach glenohumeral contrast injection with subsequent MR imaging, and 67 age- and gender-matched subjects (39 boys, 28 girls; mean age 16.0 years; range 11.1-19.2 years) who underwent a posterior approach injection during the period June 2010 to September 2015. Two pediatric radiologists independently evaluated all MR shoulder arthrograms to assess adequacy of capsular distention and degree of contrast extravasation. We recorded total fluoroscopic time, dose-area product (DAP) and cumulative air kerma (CAK). There were no significant differences in age, gender, height, weight or body mass index between the populations (P-values > 0.6). The amount of contrast extravasation between the groups was not significantly different (P = 0.27). Three anterior injections (4.5%) and one posterior (1.5%) were suboptimal (P = 0.62). Fluoroscopy time was not different: 1.1 min anterior and 1.3 min posterior (P = 0.14). There was a significant difference in CAK (0.7 mGy anterior and 1.1 mGy posterior; P = 0.007) and DAP (5.3 μGym{sup 2} anterior and 9.4 μGym{sup 2} posterior; P = 0.008). Inter-rater agreement was excellent (Cohen kappa >0.81). Both techniques were technically successful. There was no difference in the fluoroscopy time for either approach. The radiation dose was higher with the posterior approach but this is of questionable clinical significance. (orig.)

  9. Evaluation of malrotation following intramedullary nailing in a femoral shaft fracture model: Can a 3D c-arm improve accuracy?

    Science.gov (United States)

    Ramme, Austin J; Egol, Jonathan; Chang, Gregory; Davidovitch, Roy I; Konda, Sanjit

    2017-07-01

    Difficulty determining anatomic rotation following intramedullary (IM) nailing of the femur continues to be problematic for surgeons. Clinical exam and fluoroscopic imaging of the hip and knee have been used to estimate femoral version, but are inaccurate. We hypothesize that 3D c-arm imaging can be used to accurately measure femoral version following IM nailing of femur fractures to prevent rotational malreduction. A midshaft osteotomy was created in a femur Sawbone to simulate a transverse diaphyseal fracture. An intramedullary (IM) nail was inserted into the Sawbone femur without locking screws or cephalomedullary fixation. A goniometer was used to simulate four femoral version situations after IM nailing: 20° retroversion, 0° version, 15° anteversion, and 30° anteversion. In each simulated position, 3D c-arm imaging and, for comparison purposes, perfect lateral radiographs of the knee and hip were performed. The femoral version of each simulated 3D and fluoroscopic case was measured and the results were tabulated. The measured version from the 3D c-arm images was 22.25° retroversion, 0.66° anteversion, 19.53° anteversion, and 25.15° anteversion for the simulated cases of 20° retroversion, 0° version, 15° anteversion, and 30° anteversion, respectively. The lateral fluoroscopic views were measured to be 9.66° retroversion, 12.12° anteversion, 20.91° anteversion, and 18.77° anteversion for the simulated cases, respectively. This study demonstrates the utility of a novel intraoperative method to evaluate femur rotational malreduction following IM nailing. The use of 3D c-arm imaging to measure femoral version offers accuracy and reproducibility. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Patient radiation exposure during different kyphoplasty techniques.

    Science.gov (United States)

    Panizza, Denis; Barbieri, Massimo; Parisoli, Francesco; Moro, Luca

    2014-01-01

    The scope of this study was to quantify patient radiation exposure during two different techniques of kyphoplasty (KP), which differ by a cement delivery method, in order to assess whether or not one of the two used methods can reduce the patient dose. Twenty patients were examined for this investigation. One X-ray fluoroscopy unit was used for localization, navigation and monitoring of cement delivery. The patient biometric data, the setting of the fluoroscope, the exposure time and the kerma-area product (KAP) were monitored in all the procedures for anteroposterior (AP) and lateral (LL) fluoroscopic projections in order to assess the range of radiation doses imparted to the patient. Theoretical entrance skin dose (ESD) and effective dose (E) were calculated from intraoperatively measured KAP. An average ET per procedure was 1.5±0.5 min for the manual injection technique (study A) and 1.4±0.4 min for the distance delivery technique (study B) in the AP plane, while 3.2±0.7 and 5.1±0.6 min in the lateral plane, respectively. ESD was estimated as an average of 0.10±0.06 Gy for study A and 0.13±0.13 Gy for study B in the AP or/and 0.59±0.46 and 1.05±0.36 Gy in the lateral view, respectively. The cumulative mean E was 1.9±1.0 mSv procedure(-1) for study A and 3.6±0.9 mSv procedure(-1) for study B. Patient radiation exposure and associated effective dose from KP may be considerable. The technique of distance cement delivery appears to be slower than the manual injection technique and it requires a more protracted fluoroscopic control in the lateral projection, so that this system entails a higher amount of dose to the patient.

  11. Radiation exposure in transcatheter patent ductus arteriosus closure: time to tune?

    Science.gov (United States)

    Villemain, Olivier; Malekzadeh-Milani, Sophie; Sitefane, Fidelio; Mostefa-Kara, Meriem; Boudjemline, Younes

    2018-05-01

    The aims of this study were to describe radiation level at our institution during transcatheter patent ductus arteriosus occlusion and to evaluate the components contributing to radiation exposure. Transcatheter occlusion relying on X-ray imaging has become the treatment of choice for patients with patent ductus arteriosus. Interventionists now work hard to minimise radiation exposure in order to reduce risk of induced cancers. We retrospectively reviewed all consecutive children who underwent transcatheter closure of patent ductus arteriosus from January 2012 to January 2016. Clinical data, anatomical characteristics, and catheterisation procedure parameters were reported. Radiation doses were analysed for the following variables: total air kerma, mGy; dose area product, Gy.cm2; dose area product per body weight, Gy.cm2/kg; and total fluoroscopic time. A total of 324 patients were included (median age=1.51 [Q1-Q3: 0.62-4.23] years; weight=10.3 [6.7-17.0] kg). In all, 322/324 (99.4%) procedures were successful. The median radiation doses were as follows: total air kerma: 26 (14.5-49.3) mGy; dose area product: 1.01 (0.56-2.24) Gy.cm2; dose area product/kg: 0.106 (0.061-0.185) Gy.cm2/kg; and fluoroscopic time: 2.8 (2-4) min. In multivariate analysis, a weight >10 kg, a ductus arteriosus width <2 mm, complications during the procedure, and a high frame rate (15 frames/second) were risk factors for an increased exposure. Lower doses of radiation can be achieved with subsequent recommendations: technical improvement, frame rate reduction, avoidance of biplane cineangiograms, use of stored fluoroscopy as much as possible, and limitation of fluoroscopic time. A greater use of echocardiography might even lessen the exposure.

  12. ESTIMATION OF THE CONVERSION COEFFICIENTS FROM DOSE-AREA PRODUCT TO EFFECTIVE DOSE FOR BARIUM MEAL EXAMINATIONS FOR ADULT PATIENTS

    Directory of Open Access Journals (Sweden)

    A. V. Vodovatov

    2018-01-01

    Full Text Available Fluoroscopic examinations of the upper gastro-intestinal tract and, especially, barium meal examinations, are commonly performed in a majority of hospitals. These examinations are associated both with substantial individual patient doses and contribution to the collective dose from medical exposure. Effective dose estimation for this type of examinations is complicated due to: 1 the necessity to simulate the moving X-ray irradiation field; 2 differences in study structure for the individual patients; 3 subjectivity of the operators; and 4 differences in the X-ray equipment. The aim of the current study was to estimate conversion coefficients from dose-area product to effective dose for barium meal examinations for the over couch and under couch exposure conditions. The study was based on data collected in the X-ray unit of the surgical department of the St-Petersburg Mariinsky hospital. A model of patient exposure during barium meal examination was developed based on the collected data on fluoroscopy protocols and adult patient irradiation geometry. Conversion coefficients were calculated using PCXMC 2.0 software. Complete examinations were converted into a set of typical fluoroscopy phases and X-ray images, specified by the examined anatomical region and the projection of patient exposure. Conversion coefficients from dose-area product to effective dose were calculated for each phase of the examination and for the complete examination. The resulting values of the conversion coefficients are comparable with published data. Variations in the absolute values of the conversion coefficients can be explained by differences in clinical protocols, models for the estimation of the effective dose and parameters of barium meal examinations. The proposed approach for estimation of effective dose considers such important features of fluoroscopic examinations as: 1 non-uniform structure of examination, 2 significant movement of the X-ray tube within a single

  13. Parathyroid aspiration directed by angiography: an alternative to venous sampling

    International Nuclear Information System (INIS)

    Krudy, A.G.; Doppman, J.L.; Marx, S.J.; Norton, J.A.; Spiegel, A.M.; Santora, A.C. II; Aurbach, G.D.

    1984-01-01

    Not all parathyroid glands can be visualized by CT or ultrasound and, therefore, cannot be aspirated using these techniques. The authors report the localization of a parathyroid gland by arteriography and needle aspiration under fluoroscopic guidance. This technique can be used to confirm a diagnosis of hypervascular parathyroid tissue that cannot otherwise be confirmed

  14. CT-guided puncture for direct MR-arthrography of the shoulder: Description of possible techniques

    Directory of Open Access Journals (Sweden)

    Hauth E

    2016-07-01

    Full Text Available The following report describes the possible techniques of CT-guided puncture for direct magnetic resonance (MR arthrography of the shoulder. CT-guided puncture can be regarded as an alternative technique to fluoroscopic- or ultrasound-guided puncture for MR-arthrography of the shoulder with high efficiency, low dose and extremely low complication rate.

  15. Personnel dosimetry in fluoroscopy

    International Nuclear Information System (INIS)

    Baechler, S.; Gardon, M.; Bochud, F.; Sans-Merce, M.; Verdun, F.R.; Trueb, Ph.

    2006-01-01

    Physicians who frequently perform fluoroscopic examinations are exposed to high intensity radiation fields and should use protective equipment such as lead aprons, thyroid shields and lead glasses. Standard individual dosimeters are worn under the lead apron in order to measure a dose that is representative of effective dose. However, large parts of the body are not protected by the apron (e.g. arms, head). Given a protection factor for the apron of about 100, an important irradiation of a body part not under the apron could go undetected. A study was conducted to analyse this situation by measuring dose using two dosimeters, one over-apron and one under-apron, for radiologists performing frequent fluoroscopic examinations. Measurements made over six-month period show that, indeed, the use of a single under-apron dosimeter is inadequate for personnel monitoring. Large doses to the head and arms are going undetected by this technique. A method for weighting the doses measured by under- and over-apron dosimeters to obtain a value better representative of the effective dose will be proposed. (authors)

  16. Prosthetic component segmentation with blur compensation: a fast method for 3D fluoroscopy.

    Science.gov (United States)

    Tarroni, Giacomo; Tersi, Luca; Corsi, Cristiana; Stagni, Rita

    2012-06-01

    A new method for prosthetic component segmentation from fluoroscopic images is presented. The hybrid approach we propose combines diffusion filtering, region growing and level-set techniques without exploiting any a priori knowledge of the analyzed geometry. The method was evaluated on a synthetic dataset including 270 images of knee and hip prosthesis merged to real fluoroscopic data simulating different conditions of blurring and illumination gradient. The performance of the method was assessed by comparing estimated contours to references using different metrics. Results showed that the segmentation procedure is fast, accurate, independent on the operator as well as on the specific geometrical characteristics of the prosthetic component, and able to compensate for amount of blurring and illumination gradient. Importantly, the method allows a strong reduction of required user interaction time when compared to traditional segmentation techniques. Its effectiveness and robustness in different image conditions, together with simplicity and fast implementation, make this prosthetic component segmentation procedure promising and suitable for multiple clinical applications including assessment of in vivo joint kinematics in a variety of cases.

  17. Pregnancy outcome after 1st-trimester inadvertent exposure to barium sulphate as a contrast media for upper gastrointestinal tract radiography.

    Science.gov (United States)

    Han, B H; Lee, K S; Han, J Y; Choi, J S; Ahn, H K; Ryu, H M; Yang, J H; Han, H W; Nava-Ocampo, A A

    2011-10-01

    Despite barium being used as a contrast media for decades, the specific assessment of its safety in pregnant women is scarce. We are reporting the favourable pregnancy outcome in women who were inadvertently exposed to barium swallow and associated ionising radiation, early in pregnancy. A control group of age- and gravidity-matched unexposed pregnant women was also included. There were 32 live-born babies in the exposed group and 94 in the control group. Women had undergone diagnostic upper gastrointestinal tract (UGT) fluoroscopic examination at 3.3 ± 1.5 weeks' gestation. Estimated maternal radiation dose secondary to barium swallow varied widely, the maximum dose was estimated to be 2.45 mSv. Similar pregnancy outcomes were observed between the groups. The number of babies born with major malformations was not significantly different (p = 1.0) between cases and controls: one (3.1%) vs three (3.2%), respectively. In conclusion, our small prospective cohort study of women suggests no association between inadvertent exposure to ionising radiation and barium sulphate during fluoroscopic barium swallow and adverse fetal outcomes.

  18. Radiography of the equine stomach

    International Nuclear Information System (INIS)

    Dik, K.J.; Kalsbeek, H.C.

    1986-01-01

    To obtain radiographic information concerning the equine stomach, a gastrographic contrast examination is required. This study describes this procedure in detail. A powerful radiographic unit, the tubehead linked to an image intensifier and suspended by an electromechanical overhead gantry system, is required. To obtain accurately positioned radiographs during the fluoroscopic examination, a cassette holder with a stationary grid is mounted at the entrance window of the image intensifier. The examination is performed in the unsedated standing horse after 24 hours of starvation, using a combination of survey radiography and fluoroscopic viewing after the inflation of air, followed by the administration of barium sulphate suspension by stomach tube. The gastrographic contrast examination is performed in three experimental animals and 23 abnormal horses. Pneumogastrophy appeared to be valuable to diagnose gastric tumors, to differentiate between gastric tumors and other masses in the cranial abdomen, and to visualize gastric parasites, even in large horses. The use of barium sulphate suspension does not result in an adequate double contrast of the stomach, but it may aid to diagnose esophagogastric or pyloric stenosis and gastric or duodenal ulcers

  19. 2D-3D Registration of CT Vertebra Volume to Fluoroscopy Projection: A Calibration Model Assessment

    Directory of Open Access Journals (Sweden)

    P. Bifulco

    2010-01-01

    Full Text Available This study extends a previous research concerning intervertebral motion registration by means of 2D dynamic fluoroscopy to obtain a more comprehensive 3D description of vertebral kinematics. The problem of estimating the 3D rigid pose of a CT volume of a vertebra from its 2D X-ray fluoroscopy projection is addressed. 2D-3D registration is obtained maximising a measure of similarity between Digitally Reconstructed Radiographs (obtained from the CT volume and real fluoroscopic projection. X-ray energy correction was performed. To assess the method a calibration model was realised a sheep dry vertebra was rigidly fixed to a frame of reference including metallic markers. Accurate measurement of 3D orientation was obtained via single-camera calibration of the markers and held as true 3D vertebra position; then, vertebra 3D pose was estimated and results compared. Error analysis revealed accuracy of the order of 0.1 degree for the rotation angles of about 1 mm for displacements parallel to the fluoroscopic plane, and of order of 10 mm for the orthogonal displacement.

  20. Successful enteral nutrition in the treatment of esophagojejunal fistula after total gastrectomy in gastric cancer patients

    Directory of Open Access Journals (Sweden)

    Portanova Michel

    2010-08-01

    Full Text Available Abstract Background Esophagojejunal fistula is a serious complication after total gastrectomy in gastric cancer patients. This study describes the successful conservative management in 3 gastric cancer patients with esophagojejunal fistula after total gastrectomy using total enteral nutrition. Methods Between January 2004 to December 2008, 588 consecutive patients with a proven diagnosis of gastric cancer were taken to the operation room to try a curative treatment. Of these, 173 underwent total gastrectomy, 9 of them had esophagojejunal fistula (5.2%. In three selected patients a trans-anastomotic naso-enteral feeding tube was placed under fluoroscopic vision when the fistula was clinically detected and a complete polymeric enteral formula was used. Results The complete closing of the esophagojejunal fistula was obtained in day 8, 14 and 25 respectively. Conclusion In some selected cases it is possible to make a successful enteral nutrition using a feeding tube distal to the leak area inserted with the help of fluoroscopic vision. The specialized management of a gastric surgery unit and nutritional therapy unit are highlighted.

  1. Radiography of the equine stomach

    International Nuclear Information System (INIS)

    Dik, K.J.; Kalsbeek, H.C.

    1985-01-01

    To obtain radiographic information concerning the equine stomach, a gastrographic contrast examination is required. This study describes this procedure in detail. A powerful radiographic unit, the tubehead linked to an image intensifier and suspended by an electromechanical overhead gantry system, is required. To obtain accurately positioned radiographs during the fluoroscopic examination, a cassette holder with a stationary grid is mounted at the entrance window of the image intensifier. The examination is performed in the unsedated standing horse after 24 hours of starvation, using a combination of survey radiography and fluoroscopic viewing after the inflation of air, followed by the administration of barium sulphate suspension by stomach tube. The gastrographic contrast examination is performed in three experimental animals and 23 abnormal horses. Pneumogastrophy appeared to be valuable to diagnose gastric tumors, to differentiate between gastric tumors and other masses in the cranial abdomen, and to visualize gastric parasites, even in large horses. The use of barium sulphate suspension does not result in an adequate double contrast of the stomach, but it may aid to diagnose esophagogastric or pyloric stenosis and gastric or duodenal ulcers

  2. Spinal Cord Infarction after Cervical Transforaminal Epidural Steroid Injection: Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Jangsup Moon

    2017-01-01

    Full Text Available Introduction: Transforaminal epidural steroid injection (TFESI is a widely used nonsurgical procedure in the treatment of patients with radiculopathy. It is efficacious in relieving pain, but a number of complications are being reported. Recently, increasing frequency of major complications, such as spinal cord infarction and cerebral infarction, has been reported with the use of a particulate steroid within fluoroscopic-guided procedures. Methods: We report a 49-year-old man with a history of chronic cervical radiculopathy, who experienced a devastating complication after TFESI. Results: After 2 min of regular TFESI, the patient abruptly experienced muscle weakness in both upper extremities and within 5 min the patient became quadriplegic. Despite active rehabilitation, the patient remained bed-ridden 4 years after the catastrophic event. To our knowledge, this is the first reported case of spinal cord infarction that occurred after TFESI in Korea. Conclusion: Considering the risk of dreadful complications, which appear in an unpredictable manner, TFESI with fluoroscopic guidance should be done only with a nonparticulate steroid.

  3. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy

    International Nuclear Information System (INIS)

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-01-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct

  4. Technical Note: Thoracic duct embolization for treatment of chylothorax: A novel guidance technique for puncture using combined MRI and fluoroscopy.

    Science.gov (United States)

    Praveen, Alampath; Sreekumar, Karumathil Pullara; Nazar, Puthukudiyil Kader; Moorthy, Srikanth

    2012-04-01

    Thoracic duct embolization (TDE) is an established radiological interventional procedure for thoracic duct injuries. Traditionally, it is done under fluoroscopic guidance after opacifying the thoracic duct with bipedal lymphangiography. We describe our experience in usinga heavily T2W sequence for guiding thoracic duct puncture and direct injection of glue through the puncture needle without cannulating the duct.

  5. Video fluoroscopic techniques for the study of Oral Food Processing

    Science.gov (United States)

    Matsuo, Koichiro; Palmer, Jeffrey B.

    2016-01-01

    Food oral processing and pharyngeal food passage cannot be observed directly from the outside of the body without instrumental methods. Videofluoroscopy (x-ray video recording) reveals the movement of oropharyngeal anatomical structures in two dimensions. By adding a radiopaque contrast medium, the motion and shape of the food bolus can be also visualized, providing critical information about the mechanisms of eating, drinking, and swallowing. For quantitative analysis of the kinematics of oral food processing, radiopaque markers are attached to the teeth, tongue or soft palate. This approach permits kinematic analysis with a variety of textures and consistencies, both solid and liquid. Fundamental mechanisms of food oral processing are clearly observed with videofluoroscopy in lateral and anteroposterior projections. PMID:27213138

  6. Promoting fluoroscopic personal radiation protection equipment: unfamiliarity, facts and fears

    International Nuclear Information System (INIS)

    Balter, Stephen

    2017-01-01

    An incomplete understanding of risk can cause inappropriate fear. Personal protective equipment (PPE) offered for the prevention of brain cancer in interventional fluoroscopists (IR-PPE). Similar items are offered for cell-phone use (RF-PPE). Publications on fluoroscopy staff brain cancer and similar papers on cell-phone induced brain cancer were reviewed. An internet safety product search was performed, which resulted in many tens of thousands of hits. Vendor claims for either ionizing radiation or radio frequency products seldom addressed the magnitude of the risk. Individuals and institutions can buy a wide variety of safety goods. Any purchase of radioprotective equipment reduces the funds available to mitigate other safety risks. The estimated cost of averting an actuarial fatal brain cancer appears to be in the order of magnitude $10 000 000-$100 000 000. Unwarranted radiation fears should not drive the radiation protection system to the point of decreasing overall safety. (authors)

  7. Automatic brightness control algorithms and their effect on fluoroscopic imaging

    International Nuclear Information System (INIS)

    Quinn, P.W.; Gagne, R.M.

    1989-01-01

    This paper reports a computer model used to investigate the effect on dose and image quality of three automatic brightness control (ABC) algorithms used in the imaging of barium during general-purpose fluoroscopy. A model incorporating all aspects of image formation - i.e., x- ray production, phantom attenuation, and energy absorption in the CSI phosphor - was driven according to each ABC algorithm as a function of patient thickness. The energy absorbed in the phosphor was kept constant, while the changes in exposure, integral dose, organ dose, and contrast were monitored

  8. Antegrade pyelography in ureteric duplications with obstructed upper segments

    International Nuclear Information System (INIS)

    Macpherson, R.I.; Kaufman, J.M.

    1983-01-01

    Percutaneous puncture under fluoroscopic control followed by antegrade pyelography was employed in three children, two of them neonates, suspected of having complete duplication of the ureter with obstructed upper segments on the basis of the excretory pyelographic and ultrasonographic findings. This simple, uncomplicated and definitive method confirmed the diagnosis and demonstrated the course, termination and effects of the dilated ectopic ureter

  9. Three-dimensional magnetic resonance imaging overlay to assist with percutaneous transhepatic access at the time of cardiac catheterization

    International Nuclear Information System (INIS)

    Whiteside, Wendy; Christensen, Jason; Zampi, Jeffrey D

    2005-01-01

    Multimodality image overlay is increasingly used for complex interventional procedures in the cardiac catheterization lab. We report a case in which three-dimensional magnetic resonance imaging (3D MRI) overlay onto live fluoroscopic imaging was utilized to safely obtain transhepatic access in a 12-year-old patient with prune belly syndrome, complex and distorted abdominal anatomy, and a vascular mass within the liver

  10. Radiation safety evaluation of a hand-held, battery operated image intensifier

    International Nuclear Information System (INIS)

    Wilson, O.J.; Young, B.F.

    1987-01-01

    A portable, hand-held, fluoroscopic unit intended for medical and industrial use was tested to verify the claim of the manufacturers that the radiation doses to the patient and user are low, and comparable to those received from standard radiographic procedures. The first claim was substantiated but not the second. A number of concerns arising from the use of this unit are discussed

  11. Radiopaque anastomosis marker

    International Nuclear Information System (INIS)

    Elliott, D.P.; Halseth, W.L.

    1977-01-01

    This invention relates to split ring markers fabricated in whole or in part from a radiopaque material, usually metal, having the terminal ends thereof and a medial portion formed to define eyelets by means of which said marker can be sutured to the tissue at the site of an anastomosis to provide a visual indication of its location when examined fluoroscopically

  12. Renal tissue damage induced by focused shock waves

    Science.gov (United States)

    Ioritani, N.; Kuwahara, M.; Kambe, K.; Taguchi, K.; Saitoh, T.; Shirai, S.; Orikasa, S.; Takayama, K.; Lush, P. A.

    1990-07-01

    Biological evidence of renal arterial wall damage induced by the microjet due to shock wave-cavitation bubble interaction was demonstrated in living dog kidneys. We also intended to clarify the mechanism of renal tissue damage and the effects of different conditions of shock wave exposure (peak pressure of focused area, number of shots, exposure rate) on the renal tissue damage in comparison to stone disintegration. Disruption of arterial wall was the most remarkable histological change in the focused area of the kidneys. This lesion appeared as if the wall had been punctured by a needle. Large hematoma formation in the renal parenchym, and interstitial hemorrhage seemed to be the results of the arterial lesion. This arterial disorder also led to ischemic necrosis of the tubules surrounding the hematoma. Micro-angiographic examination of extracted kidneys also proved such arterial puncture lesions and ischemic lesions. The number of shots required for model stone disintegration was not inversely proportional to peak pressure. It decreased markedly when peak pressure was above 700 bar. Similarly thenumber of shots for hematoma formation was not inversely proportional to peak pressure, however, this decreased markedly above 500 bar. These results suggested that a hematoma could be formed under a lower peak pressure than that required for stone disintegration.

  13. How should low-contrast detail detectability be measured in fluoroscopy?

    International Nuclear Information System (INIS)

    Tapiovaara, Markku J.; Sandborg, Michael

    2004-01-01

    The relationship and precision of four methods for measuring the low-contrast detail detectability in fluoroscopic imaging were studied. These included the physical measurement of the accumulation rate of the square of the signal-to-noise ratio (SNR rate 2 ), two-alternative forced-choice (2-AFC) experiments, sixteen-alternative forced-choice (16-AFC) experiments and subjective determination of the threshold contrast. The precision and sensitivity of the threshold contrast measurement were seen to be modest in the constancy testing of fluoroscopic equipment: only large changes in system performance could be reliably detected by that method. The measurement of the SNR rate 2 is suggested instead. The relationship between the results of the various methods were studied, and it was found that human performance can be related to SNR rate 2 by introducing the concept of the effective image information integration time (t eff ). When measured for an unlimited observation time, it depicts the saturation of human performance in detecting a static low-contrast detail in dynamic image noise. Here, t eff was found to be about 0.6 s in 2-AFC tests and 0.3 s in 16-AFC tests

  14. Fluoroscopy-Guided Percutaneous Gallstone Removal Using a 12-Fr Sheath in High-Risk Surgical Patients with Acute Cholecystitis

    International Nuclear Information System (INIS)

    Kim, Young Hwan; Kim, Yong Joo; Shin, Tae Beom

    2011-01-01

    To evaluate the technical feasibility and clinical efficacy of percutaneous transhepatic cholecystolithotomy under fluoroscopic guidance in high-risk surgical patients with acute cholecystitis. Sixty-three consecutive patients of high surgical risk with acute calculous cholecystitis underwent percutaneous transhepatic gallstone removal under conscious sedation. The stones were extracted through the 12-Fr sheath using a Wittich nitinol stone basket under fluoroscopic guidance on three days after performing a percutaneous cholecystostomy. Large or hard stones were fragmented using either the snare guide wire technique or the metallic cannula technique. Gallstones were successfully removed from 59 of the 63 patients (94%). Reasons for stone removal failure included the inability to grasp a large stone in two patients, and the loss of tract during the procedure in two patients with a contracted gallbladder. The mean hospitalization duration was 7.3 days for acute cholecystitis patients and 9.4 days for gallbladder empyema patients. Bile peritonitis requiring percutaneous drainage developed in two patients. No symptomatic recurrence occurred during follow-up (mean, 608.3 days). Fluoroscopy-guided percutaneous gallstone removal using a 12-Fr sheath is technically feasible and clinically effective in high-risk surgical patients with acute cholecystitis

  15. A PROSPECTIVE STUDY OF CLINICAL OUTCOME AFTER USING LIGAMENTOTAXIS IN MANAGEMENT OF DISTAL RADIUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Chandrashekhar V. Mudgal

    2017-04-01

    Full Text Available BACKGROUND A study was done to evaluate the effect of the ligamentotaxis in the management of intraarticular fractures of the distal radius. MATERIALS AND METHODS 34 patients were studied prospectively between March 2014 and February 2016. All patients had intraarticular fracture of distal end of radius and all were treated with ligamentotaxis after closed reduction with fluoroscopic guidance. The follow-up period was 12 months. At the time of surgery, the mean age was 45.29 years. RESULTS In all fracture cases, the mean of fracture union was 5.8 weeks. During the final follow-up, the mean range of motion was 55.30 in flexion, 56.60 in extension, 21.0 in ulnar deviation, 9.00 in radial deviation, 70.30 in pronation and 67.10 in supination. According to the scoring system of Gartland and Werley, the clinical and functional outcomes showed that 15 patients (44.1% had excellent results, 14 (41.1% had good results, 3 (8.8% had fair results and 2 (5.8% had poor results. CONCLUSION Closed reduction under fluoroscopic image guidance and the ligamentotaxis is useful and effective in the treatment of intraarticular fractures of the distal radius.

  16. Multi-modal imaging, model-based tracking, and mixed reality visualisation for orthopaedic surgery

    Science.gov (United States)

    Fuerst, Bernhard; Tateno, Keisuke; Johnson, Alex; Fotouhi, Javad; Osgood, Greg; Tombari, Federico; Navab, Nassir

    2017-01-01

    Orthopaedic surgeons are still following the decades old workflow of using dozens of two-dimensional fluoroscopic images to drill through complex 3D structures, e.g. pelvis. This Letter presents a mixed reality support system, which incorporates multi-modal data fusion and model-based surgical tool tracking for creating a mixed reality environment supporting screw placement in orthopaedic surgery. A red–green–blue–depth camera is rigidly attached to a mobile C-arm and is calibrated to the cone-beam computed tomography (CBCT) imaging space via iterative closest point algorithm. This allows real-time automatic fusion of reconstructed surface and/or 3D point clouds and synthetic fluoroscopic images obtained through CBCT imaging. An adapted 3D model-based tracking algorithm with automatic tool segmentation allows for tracking of the surgical tools occluded by hand. This proposed interactive 3D mixed reality environment provides an intuitive understanding of the surgical site and supports surgeons in quickly localising the entry point and orienting the surgical tool during screw placement. The authors validate the augmentation by measuring target registration error and also evaluate the tracking accuracy in the presence of partial occlusion. PMID:29184659

  17. 3D roadmap in neuroangiography: technique and clinical interest

    International Nuclear Information System (INIS)

    Soederman, Michael; Andersson, T.; Babic, D.; Homan, R.

    2005-01-01

    We present the first clinical results obtained with a novel technique: the three-dimensional [3D] roadmap. The major difference from the standard 2D digital roadmap technique is that the newly developed 3D roadmap is based on a rotational angiography acquisition technique with the two-dimensional [2D] fluoroscopic image as an overlay. Data required for an accurate superimposition of the previously acquired 3D reconstructed image on the interactively made 2D fluoroscopy image, in real time, are stored in the 3D workstation and constitute the calibration dataset. Both datasets are spatially aligned in real time; thus, the 3D image is accurately superimposed on the 2D fluoroscopic image regardless of any change in C-arm position or magnification. The principal advantage of the described roadmap method is that one contrast injection allows the C-arm to be positioned anywhere in the space and allows alterations in the distance between the x-ray tube and the image intensifier as well as changes in image magnification. In the clinical setting, the 3D roadmap facilitated intravascular neuronavigation with concurrent reduction of procedure time and use of contrast medium. (orig.)

  18. Critical analysis of dose reduction trends with special reference to procedures involved in fluoroscopy

    International Nuclear Information System (INIS)

    Anderson, K.; Mattsson, O.

    1985-01-01

    Experiences of a half-year's use of dose-checking instrumentation in fluoroscopy are presented. Radiologists under training succeeded in lowering the patient dose surprisingly well - the diagnostic results remaining unchanged or even improving, because of higher image quality as a result of better diaphragming. Other factors involved in fluoroscopy are discussed. Present systems with heavy bulky intensifiers create problems for close patient contact and for the necessary manipulation, patient adjustment and application of compression. The examination will be simplified and facilitated by the use of a flat image system: proper adjustments need fewer fluoroscopic observations, and patient dose as well as examination time can be saved. Flat display principles will take over the function of the present old-fashioned intensifiers and monitors, either as single units or equipped with TV, video or digital processing accessories. A flat image system, the 'PET-scope', was tested and found to be very convenient for fluoroscopic procedures. The physical properties were studied thoroughly - the high intensification particularly gives these systems an advantage in dose reduction. New applications are possible with these light-weight low-dose units. Fluoroscopy represents a field where considerable contributions to the 'Quality Assurance' trend can be obtained. (author)

  19. Oesophageal dosimetry during cardial catheterisation

    International Nuclear Information System (INIS)

    Noel, A.; Aletti, P.; Claudon, M.; Hoeffel, J.C.; Lostette, Y.

    1981-01-01

    The purpose of this two-fold study has been the measurement of absorbed dose to patients during cardiac catheterization. Radiothermoluminescence (RTL), the method of choice for dosimetry in vivo, has been used extensively in this work. The first part of the study involved 49 unselected patients. A ratio (the equivalent fluoroscopic time) was established between the duration of fluoroscopy and the length of film exposed; this simplified the calculation of patient-dose. The dose absorbed in a central region of the mediastinum was designated the heart dose and was calculated by means of a formula in which the variables were fluoroscopic time and length of film. It was shown that the dose absorbed was unrelated to the thoracic thickness of the patients examined. The second part of the study was confined to 15 selected patients; infants and young children could not be included because of the requirement to insert an oesophageal catheter. The catheter was made of flexible polyethylene with a lithium fluoride tip enabling measurement of the dose within the oesophagus. Employing this technique, we were able to confirm the accuracy of our earlier study by comparing the measured oesophageal dose with the estimated heart dose [fr

  20. Technical feasibility of 2D-3D coregistration for visualization of self-expandable microstents to facilitate coil embolization of broad-based intracranial aneurysms: an in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Richter, Gregor [University of Erlangen-Nuernberg, Department of Neuroradiology, Erlangen (Germany); Kreisklinikum Siegen, Department of Radiology and Neuroradiology, Siegen (Germany); Pfister, Marcus [Siemens AG, Healthcare Sector, Forchheim (Germany); Struffert, Tobias; Engelhorn, Tobias; Doelken, Marc; Doerfler, Arnd [University of Erlangen-Nuernberg, Department of Neuroradiology, Erlangen (Germany); Spiegel, Martin; Hornegger, Joachim [University of Erlangen, Department of Informatics 5, Erlangen (Germany)

    2009-12-15

    The use of self-expandable microstents for treatment of broad-based intracranial aneurysms is widely spread. However, poor fluoroscopic visibility of the stents remains disadvantageous during the coiling procedure. Flat detector angiographic computed tomography (ACT) provides high resolution imaging of microstents even though integration of this imaging modality in the neurointerventional workflow has not been widely reported. An acrylic glass model was used to simulate the situation of a broad-based sidewall aneurysm. After insertion of a self-expandable microstent, ACT was performed. The resulting 3D dataset of the Microstent was subsequently projected into a conventional 2D fluoroscopic roadmap. This 3D visualization of the stent supported the coil embolization procedure of the in vitro aneurysm. In vitro 2D-3D coregistration with integration of 3D ACT data of a self-expandable microstent in a conventional 2D roadmap is feasible. Unsatisfying stent visibility constrains clinical cases with complex parent vessel anatomy and challenging aneurysm geometry; hence, this technique potentially may be useful in such cases. In our opinion, the clinical feasibility and utility of this new technique should be verified in a clinical aneurysm embolization study series using 2D-3D coregistration. (orig.)

  1. The role of the MR-fluoroscopy in the diagnosis and staging of the pelvic organ prolapse

    International Nuclear Information System (INIS)

    Etlik, Oemer; Arslan, Halil; Odabasi, Oner; Odabasi, Hulya; Harman, Mustafa; Celebi, Hacer; Sakarya, M. Emin

    2005-01-01

    Introduction: The aim of the study is to investigate the efficacy of the magnetic resonance fluoroscopy in the diagnosis and staging of the pelvic prolapse. Materials and methods: The study consisted of 46 patients who were known to have pelvic prolapses from their vaginal examination. Thirty women who underwent vaginal exam and shown not have pelvic prolapse were selected as a control group. Firstly, pelvic sagittal FSE T2 weighted images of all the women were acquired in 0.3 T open MR equipment than sagittal MR-fluoroscopic images using spoiled gradient echo sequences were obtained during pelvic strain. Physical examination and MR-fluoroscopic findings were compared. The relationship between the stages of prolapse established by both of the methods was evaluated statistically with Pearson's correlation analysis. Results: Physical examination and MR findings were very concordant in the diagnosis of pelvic prolapse and statistical correlations in the stages of prolapse were established between both of the methods (P<0.01 for anterior and middle comportment, P<0.05 for posterior comportment). Conclusion: We conclude that MR-fluoroscopy is a non-invasive, easily applied, dynamic useful method without contrast agent in the diagnosis and staging of pelvic organ prolapse

  2. Fluoroscopy-Guided Percutaneous Gallstone Removal Using a 12-Fr Sheath in High-Risk Surgical Patients with Acute Cholecystitis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hwan [Keimyung University, College of Medicine, Daegu (Korea, Republic of); Kim, Yong Joo [Andong General Hospital, Andong (Korea, Republic of); Shin, Tae Beom [Gyeonsang National University, College of Medicine, Jinju (Korea, Republic of)

    2011-04-15

    To evaluate the technical feasibility and clinical efficacy of percutaneous transhepatic cholecystolithotomy under fluoroscopic guidance in high-risk surgical patients with acute cholecystitis. Sixty-three consecutive patients of high surgical risk with acute calculous cholecystitis underwent percutaneous transhepatic gallstone removal under conscious sedation. The stones were extracted through the 12-Fr sheath using a Wittich nitinol stone basket under fluoroscopic guidance on three days after performing a percutaneous cholecystostomy. Large or hard stones were fragmented using either the snare guide wire technique or the metallic cannula technique. Gallstones were successfully removed from 59 of the 63 patients (94%). Reasons for stone removal failure included the inability to grasp a large stone in two patients, and the loss of tract during the procedure in two patients with a contracted gallbladder. The mean hospitalization duration was 7.3 days for acute cholecystitis patients and 9.4 days for gallbladder empyema patients. Bile peritonitis requiring percutaneous drainage developed in two patients. No symptomatic recurrence occurred during follow-up (mean, 608.3 days). Fluoroscopy-guided percutaneous gallstone removal using a 12-Fr sheath is technically feasible and clinically effective in high-risk surgical patients with acute cholecystitis

  3. Fallopian tube occlusion by selective transcatheter radiofrequency electrocautery

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Joo Hyeong; Yoon, Yup; Ko, Young Tae; Nam, Duck Ho; Park, Yong Koo [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1998-04-01

    The purpose of this study is to access the usefulness of transcatheter radiofrequency (RF) electrocautery as a method of nonsurgical tubal occlusion. Using the coaxial technique under fluoroscopic guidance, transvaginal fluoroscopic fallopian tube catheterization was performed in thirteen rabbits. In each rabbit, unilateral tubal ablation was performed using RF electrocautery. A 0.018 inch metallic wire protruding from the microcatheter tip was used as the source of the RF energy; the length of the noninsulated part of this wire was 10 mm and the duration of RF energy; the length of the noninsulated part of this wire 10 mm and the duration of RF supply was 20 seconds. The contralateral normal fallopian tube and uterus were used as a control. All 13 rabbits were randomly sacrificed on two days (group I) or 30 days (group II) after the procedure, and tubal patency and histologic change were evaluated. Transcatheter RF electrocautery is though to be a useful method for tubal occlusion. It is simple, safe, and less expensive and might have a role in future female tubal sterilization. (author). 25 refs., 1 tab., 4 figs.

  4. Fallopian tube occlusion by selective transcatheter radiofrequency electrocautery

    International Nuclear Information System (INIS)

    Oh, Joo Hyeong; Yoon, Yup; Ko, Young Tae; Nam, Duck Ho; Park, Yong Koo

    1998-01-01

    The purpose of this study is to access the usefulness of transcatheter radiofrequency (RF) electrocautery as a method of nonsurgical tubal occlusion. Using the coaxial technique under fluoroscopic guidance, transvaginal fluoroscopic fallopian tube catheterization was performed in thirteen rabbits. In each rabbit, unilateral tubal ablation was performed using RF electrocautery. A 0.018 inch metallic wire protruding from the microcatheter tip was used as the source of the RF energy; the length of the noninsulated part of this wire was 10 mm and the duration of RF energy; the length of the noninsulated part of this wire 10 mm and the duration of RF supply was 20 seconds. The contralateral normal fallopian tube and uterus were used as a control. All 13 rabbits were randomly sacrificed on two days (group I) or 30 days (group II) after the procedure, and tubal patency and histologic change were evaluated. Transcatheter RF electrocautery is though to be a useful method for tubal occlusion. It is simple, safe, and less expensive and might have a role in future female tubal sterilization. (author). 25 refs., 1 tab., 4 figs

  5. Technical feasibility of 2D-3D coregistration for visualization of self-expandable microstents to facilitate coil embolization of broad-based intracranial aneurysms: an in vitro study

    International Nuclear Information System (INIS)

    Richter, Gregor; Pfister, Marcus; Struffert, Tobias; Engelhorn, Tobias; Doelken, Marc; Doerfler, Arnd; Spiegel, Martin; Hornegger, Joachim

    2009-01-01

    The use of self-expandable microstents for treatment of broad-based intracranial aneurysms is widely spread. However, poor fluoroscopic visibility of the stents remains disadvantageous during the coiling procedure. Flat detector angiographic computed tomography (ACT) provides high resolution imaging of microstents even though integration of this imaging modality in the neurointerventional workflow has not been widely reported. An acrylic glass model was used to simulate the situation of a broad-based sidewall aneurysm. After insertion of a self-expandable microstent, ACT was performed. The resulting 3D dataset of the Microstent was subsequently projected into a conventional 2D fluoroscopic roadmap. This 3D visualization of the stent supported the coil embolization procedure of the in vitro aneurysm. In vitro 2D-3D coregistration with integration of 3D ACT data of a self-expandable microstent in a conventional 2D roadmap is feasible. Unsatisfying stent visibility constrains clinical cases with complex parent vessel anatomy and challenging aneurysm geometry; hence, this technique potentially may be useful in such cases. In our opinion, the clinical feasibility and utility of this new technique should be verified in a clinical aneurysm embolization study series using 2D-3D coregistration. (orig.)

  6. Self-expendable metallic stents for palliative treatment of malignant esophagogastric strictures: experiences in 103 patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sun Ah; Do, Young Soo; Lee, Byung Hee; Oh, Hoon Il; Kim, Soo Ah; Kim, Ki Soo; Chin, Soo Yil [Korea Cancer Center Hospital, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate the effects and complication of self-expandable metallic stent for the treatment of malignant esophagogastric strictures. From September 1991 to March 1995, 110 stents were placed under fluoroscopic guidance in 103 patients. Of the 103 patients, there were 73 patients with esophageal cancer, 14 patients with gastric cancer, 12 patients with recurrence after surgery, three patients with esophageal compression by metastatic mediastinal lymphadenopathy, and one patient with esophageal invasion by lung cancer. Seventeen patients had esophagorespiratory fistulas. Under fluoroscopic guidance, 113 self-expandable metallic stents (99 Song stents, 14 Strecker stents) were placed in 103 patients. After stent placement, 68 (66%) of the patients could ingest solid food, 26 (25.2%) could ingest soft food whereas three (2.9%) were not able to have food. Esophagorespiratory fistulas were occluded immediately after stent insertion. All stents were placed without any technical failures or procedural morbidity or mortality. Complications included restenosis in 13, gastroesophageal reflux in 11, stent tube migration in eight, massive bleeding in four, delayed esophageal perforation in one, stent obstruction by food impaction in one patient. Self-expandable metallic stent seems to be relatively safe and effective procedure in the palliative treatment of malignant esophagogastric stricture.

  7. Authentication of two samples of ancient Chinese coins with component element depth analysis by confocal 3D XRF

    Science.gov (United States)

    Zhou, Peng; Liu, Zhiguo; Lin, Xiaoyan; Liu, Xin; Ye, Lei; Wang, Xingyi; Pan, Kai; Li, Yude

    2018-05-01

    Two samples of ancient Chinese coins were analyzed with a confocal three-dimensional micro-X-ray fluoroscope. The depth distributions of elemental iron (Fe), calcium (Ca) and copper (Cu) were obtained based on this non-destructive measurement method. One coin, named "Chongning Tongbao", was certified as genuine in accordance with the available archaeological data, whereas another coin, named "Zhenglong Yuanbao", was identified as a reproduction.

  8. Three-dimensional magnetic resonance imaging overlay to assist with percutaneous transhepatic access at the time of cardiac catheterization

    Directory of Open Access Journals (Sweden)

    Wendy Whiteside

    2015-01-01

    Full Text Available Multimodality image overlay is increasingly used for complex interventional procedures in the cardiac catheterization lab. We report a case in which three-dimensional magnetic resonance imaging (3D MRI overlay onto live fluoroscopic imaging was utilized to safely obtain transhepatic access in a 12-year-old patient with prune belly syndrome, complex and distorted abdominal anatomy, and a vascular mass within the liver.

  9. Proportional lumbar spine inter-vertebral motion patterns: a comparison of patients with chronic, non-specific low back pain and healthy controls

    OpenAIRE

    Mellor, Fiona E.; Thomas, Peter; Thompson, Paul W.; Breen, Alan C.

    2014-01-01

    Introduction: Identifying biomechanical subgroups in chronic, non-specific low back pain (CNSLBP) populations from inter-vertebral displacements has proven elusive. Quantitative fluoroscopy (QF) has excellent repeatability and provides continuous standardised inter-vertebral kinematic data from fluoroscopic sequences allowing assessment of mid-range motion. The aim of this study was to determine whether proportional continuous IV rotational patterns were different in patients and controls. A ...

  10. X-ray television system, SHIMAVISION 3200X

    International Nuclear Information System (INIS)

    Nagata, Takashi; Takemoto, Hajime; Nakamura, Masanori; Imanishi, Tetsuo

    1990-01-01

    X-ray television system 'SHIMAVISION 3200X' has been developed. This system has achieved large image size in radiography and fluoroscopy utilizing up to 17inch x 14inch cassette radiographic function attached to 2 channel 3 size cassetteless spotfilm device and utilizing 12inch I.I. at same table top height as 9inch I.I. Newly designed image processor makes fluoroscopic image high quality. (author)

  11. Augmented reality fluoroscopy simulation of the guide-wire insertion in DHS surgery: A proof of concept study.

    Science.gov (United States)

    van Duren, B H; Sugand, K; Wescott, R; Carrington, R; Hart, A

    2018-05-01

    Hip fractures contribute to a significant clinical burden globally with over 1.6 million cases per annum and up to 30% mortality rate within the first year. Insertion of a dynamic hip screw (DHS) is a frequently performed procedure to treat extracapsular neck of femur fractures. Poorly performed DHS fixation of extracapsular neck of femur fractures can result in poor mobilisation, chronic pain, and increased cut-out rate requiring revision surgery. A realistic, affordable, and portable fluoroscopic simulation system can improve performance metrics in trainees, including the tip-apex distance (the only clinically validated outcome), and improve outcomes. We developed a digital fluoroscopic imaging simulator using orthogonal cameras to track coloured markers attached to the guide-wire which created a virtual overlay on fluoroscopic images of the hip. To test the accuracy with which the augmented reality system could track a guide-wire, a standard workshop femur was used to calibrate the system with a positional marker fixed to indicate the apex; this allowed for comparison between guide-wire tip-apex distance (TAD) calculated by the system to be compared to that physically measured. Tests were undertaken to determine: (1) how well the apex could be targeted; (2) the accuracy of the calculated TAD. (3) The number of iterations through the algorithm giving the optimal accuracy-time relationship. The calculated TAD was found to have an average root mean square error of 4.2 mm. The accuracy of the algorithm was shown to increase with the number of iterations up to 20 beyond which the error asymptotically converged to an error of 2 mm. This work demonstrates a novel augmented reality simulation of guide-wire insertion in DHS surgery. To our knowledge this has not been previously achieved. In contrast to virtual reality, augmented reality is able to simulate fluoroscopy while allowing the trainee to interact with real instrumentation and performing the procedure on

  12. Patient radiation exposure during different kyphoplasty techniques

    International Nuclear Information System (INIS)

    Panizza, D.; Barbieri, M.; Parisoli, F.; Moro, L.

    2014-01-01

    The scope of this study was to quantify patient radiation exposure during two different techniques of kyphoplasty (KP), which differ by a cement delivery method, in order to assess whether or not one of the two used methods can reduce the patient dose. Twenty patients were examined for this investigation. One X-ray fluoroscopy unit was used for localization, navigation and monitoring of cement delivery. The patient bio-metric data, the setting of the fluoroscope, the exposure time and the kerma-area product (KAP) were monitored in all the procedures for anteroposterior (AP) and lateral (LL) fluoroscopic projections in order to assess the range of radiation doses imparted to the patient. Theoretical entrance skin dose (ESD) and effective dose (E) were calculated from intraoperatively measured KAP. An average ET per procedure was 1.5±0.5 min for the manual injection technique (study A) and 1.4±0.4 min for the distance delivery technique (study B) in the AP plane, while 3.2±0.7 and 5.1±0.6 min in the lateral plane, respectively. ESD was estimated as an average of 0.10±0.06 Gy for study A and 0.13±0.13 Gy for study B in the AP or/and 0.59±0.46 and 1.05±0.36 Gy in the lateral view, respectively. The cumulative mean E was 1.9±1.0 mSv procedure -1 for study A and 3.6±0.9 mSv procedure -1 for study B. Patient radiation exposure and associated effective dose from KP may be considerable. The technique of distance cement delivery appears to be slower than the manual injection technique and it requires a more protracted fluoroscopic control in the lateral projection, so that this system entails a higher amount of dose to the patient. (authors)

  13. Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

    OpenAIRE

    Binder Ronald K; Leipsic Jonathon; Wood David; Moore Teri; Toggweiler Stefan; Willson Alex; Gurvitch Ronen; Freeman Melanie; Webb John G

    2012-01-01

    BACKGROUND Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities including multidetector computed tomography (MDCT) have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3 dimensional angiographic reconstructions (3DA) of the aortic root for prediction of the optimal deployment angle and compared it with MDCT. METHODS AND RES...

  14. Diaphragmatic Hernia After Radiofrequency Ablation for Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Yoshimatsu, Rika; Matsushima, Shigenori; Tanaka, Osamu; Miura, Hiroshi; Nishimura, Tsunehiko

    2011-01-01

    We describe a 71-year-old woman with a hepatocellular carcinoma who underwent percutaneous radiofrequency ablation (RF) with a single internally cooled electrode under computed tomography (CT) fluoroscopic guidance. Nine months after the procedure, CT images showed herniation of the large intestine into the right pleural cavity. To our knowledge this complication of RF performed with a single internally cooled electrode under CT guidance has not been previously reported.

  15. An objective spinal motion imaging assessment (OSMIA): reliability, accuracy and exposure data.

    OpenAIRE

    Breen, Alan C.; Muggleton, J.M.; Mellor, F.E.

    2006-01-01

    Abstract Background Minimally-invasive measurement of continuous inter-vertebral motion in clinical settings is difficult to achieve. This paper describes the reliability, validity and radiation exposure levels in a new Objective Spinal Motion Imaging Assessment system (OSMIA) based on low-dose fluoroscopy and image processing. Methods Fluoroscopic sequences in coronal and sagittal planes were obtained from 2 calibration models using dry lumbar vertebrae, plus the lumbar spines of 30 asymptom...

  16. Electronic portal imaging devices

    International Nuclear Information System (INIS)

    Lief, Eugene

    2008-01-01

    The topics discussed include, among others, the following: Role of portal imaging; Port films vs. EPID; Image guidance: Elekta volume view; Delivery verification; Automation tasks of portal imaging; Types of portal imaging (Fluorescent screen, mirror, and CCD camera-based imaging; Liquid ion chamber imaging; Amorpho-silicon portal imagers; Fluoroscopic portal imaging; Kodak CR reader; and Other types of portal imaging devices); QA of EPID; and Portal dosimetry (P.A.)

  17. A surprise case of colonic interposition

    International Nuclear Information System (INIS)

    Law, Robert

    2006-01-01

    Blind nasogastric intubation failure as a result of changes to the normal anatomical pathway is not uncommon. This case report is of fluoroscopically guided intubation in a patient in whom blind intubation failed as a result of what was subsequently found to be a colonic interposition with associated late complications. Fluroscopically guided nasogastric intubation is a safe and effective procedure that should always be considered when blind intubation has failed

  18. Translations on People’s Republic of China, Number 390

    Science.gov (United States)

    1977-08-15

    machine, chemical refrigerators, high transparency fluoroscopic screen, radiotherapy localization model machine, and peritoneal dialysis machine. Some...PAO, 1 Apr 77) 18 Treatment of Carcinoma Being Studied, Improved (TA KUNG PAO, 6 Apr 77) 21 Medical Instrument Industry Increases Production...4th 5-year plan, the growth rate rose to 18.4 percent. Nan-ning city adheres to the policy of "small, native, mass" and successfully promotes

  19. The role and impact of reference doses on diagnostic radiology, how to use them at the national level?

    International Nuclear Information System (INIS)

    Nikodemova, D.; Horvathova, M.; Karkus, R.

    2003-01-01

    Results of patient dose audits reported in this paper for several types of examinations and various technical units have shown the importance of applications of reference dose levels in radiological practice. On the basis of national surveys slightly lower or higher standard dose reference levels (DRL) values could be justified. Continuing revision of DRL values and their extension to other types of radiographic and fluoroscopic examinations is needed

  20. Patient dose assessment from fluoroscopic procedures at Korle-Bu Teaching Hospital

    International Nuclear Information System (INIS)

    Gyekye, P. K.

    2008-06-01

    Organ and effective dose to ninety (90) patients undergoing myelogram, urethrogram, barium swallow, barium meal and barium enema examinations at the KorIe-Bu Teaching Hospital was estimated using the Monte Carlo Code (PCXMC). Free in air measurements were made with a calibrated ionisation chamber to estimate the entrance surface air kerma for each examination. Evaluation of fluoroscopy beam on time and number of radiographs taken per patient was done for all the examinations considered and studies were done on how they affect patient dose. Dose area product (DAP) was calculated from the entrance surface air kerma and the area of the beam on the surface of the patient and compared with internationally accepted reference levels. Excess relative risk of site specific solid cancer and all solid cancers excluding thyroid and Non-melanoma skin cancers incidences were estimated for the various examinations using Biological Effects of Ionising Radiation VII Committee risk model from the knowledge of the mean effective doses for each examination. The mean effective dose was found to be 0.29 :±: 0.07 mSv for urethrogram, 0.84:±: 0.13 mSv for barium swallow, 3.15 :±: 0.44 mSv for barium meal, 6.24 :±: 0.7 mSv for barium enema and 0.38 :I: 0.05 mSv for myelogram examinations. The estimated mean dose area product (DAP) was found to be 3.55 :±: 0.95 Gycm2 for urethrogram, 16.44:1: 2.60 Gycm2 for barium swallow, 50.81 :±: 7.04 Gycm2 for barium meal, 99.69 :±: 10.85 Gycm2 for barium enema and 9.32 :±: 0.99 Gycm2 for myelogram examinations. The estimated excess relative risk for the occurrence of all solid cancer was found to be 9.5700E-S and 1.6530E-4 for males and females respectively undergoing urethrogram examination, 2.7720E-4 and 4.7880E-4 for males and females respectively undergoing barium swallow examination, 1.0395E-3 and 1.7955E-3 for males and females respectively undergoing barium meal examination, 2.0592E-3 and 3.5568E-3 for males and females respectively undergoing barium enema, 1.6500E-5 and 2.8500E-5 for males and females respectively undergoing myelogram examination. Longer radiation beam on time, high number of radiographs taken per patient, wide exposure beam area on the surface of the patient was found to contribute to increased doses in patient. Radiologist should optimise their practises at Korle-Bu Teaching Hospital to reduce dose to patients. (au)

  1. Influence of Flat-Panel Fluoroscopic Equipment Variables on Cardiac Radiation Doses

    International Nuclear Information System (INIS)

    Nickoloff, Edward L.; Lu Zhengfeng; Dutta, Ajoy; So, James; Balter, Stephen; Moses, Jeffrey

    2007-01-01

    Purpose. To assess the influence of physician-selectable equipment variables on the potential radiation dose reductions during cardiac catheterization examinations using modern imaging equipment. Materials. A modern bi-plane angiography unit with flat-panel image receptors was used. Patients were simulated with 15-30 cm of acrylic plastic. The variables studied were: patient thickness, fluoroscopy pulse rates, record mode frame rates, image receptor field-of-view (FoV), automatic dose control (ADC) mode, SID/SSD geometry setting, automatic collimation, automatic positioning, and others. Results. Patient radiation doses double for every additional 3.5-4.5 cm of soft tissue. The dose is directly related to the imaging frame rate; a decrease from 30 pps to 15 pps reduces the dose by about 50%. The dose is related to [(FoV) -N ] where 2.0 < N < 3.0. Suboptimal positioning of the patient can nearly double the dose. The ADC system provides three selections that can vary the radiation level by 50%. For pediatric studies (2-5 years old), the selection of equipment variables can result in entrance radiation doses that range between 6 and 60 cGy for diagnostic cases and between 15 and 140 cGy for interventional cases. For adult studies, the equipment variables can produce entrance radiation doses that range between 13 and 130 cGy for diagnostic cases and between 30 and 400 cGy for interventional cases. Conclusions. Overall dose reductions of 70-90% can be achieved with pediatric patients and about 90% with adult patients solely through optimal selection of equipment variables

  2. Development of a 3-dimensional CT using an image intensifier

    International Nuclear Information System (INIS)

    Toyofuku, Fukai

    1992-01-01

    A prototype of three-dimensional CT (Fluoroscopic CT) has been developed using an image intensifier as a two-dimensional X-ray detector. A patient on a rotating table is projected onto an image intensifier by a cone beam of X-ray from the X-ray tube. A total of 390 projection images covering 180 degrees are acquired in a single scan (13 sec) and stored on a digital frame recorder (512 x 256 x 8-bit x 480). The transverse axial images are reconstructed by using the usual CT reconstruction algorithm, while longitudinal section images such as sagittal, coronal, oblique, and panoramic images are obtained by directly back-projecting the filtered projection image onto the sections. The radiation exposure was measured with an ionization chamber, and the exposure of the present fluoroscopic CT is about 10 to 20 times less than that of conventional X-ray CT. A similar monochromatic X-ray CT system has also been developed using synchrotron radiation. Large area parallel X-rays are obtained from a wiggler beam using a silicon crystal with [311] asymmetric reflection. By taking two images above and below iodine K-absorption edge (33.17 keV), iodine image is obtained. (author)

  3. In vivo cartilage contact deformation in the healthy human tibiofemoral joint.

    Science.gov (United States)

    Bingham, J T; Papannagari, R; Van de Velde, S K; Gross, C; Gill, T J; Felson, D T; Rubash, H E; Li, G

    2008-11-01

    In vivo cartilage contact deformation is instrumental for understanding human joint function and degeneration. This study measured the total deformation of contacting articular cartilage in the human tibiofemoral joint during in vivo weight-bearing flexion. Eleven healthy knees were magnetic resonance (MR) scanned and imaged with a dual fluoroscopic system while the subject performed a weight-bearing single-leg lunge. The tibia, femur and associated articulating cartilage were constructed from the MR images and combined with the dual fluoroscopic images to determine in vivo cartilage contact deformation from full extension to 120 degrees of flexion. In both compartments, minimum peak compartmental contact deformation occurred at 30 degrees of flexion (24 +/- 6% medial, 17 +/- 7% lateral) and maximum peak compartmental deformation occurred at 120 degrees of flexion (30 +/- 13% medial, 30 +/- 10% lateral) during the weight-bearing flexion from full extension to 120 degrees. Average medial contact areas and peak contact deformations were significantly greater than lateral compartment values (P In addition, cartilage thickness in regions of contact was on average 1.4- and 1.1-times thicker than the average thickness of the tibial and femoral cartilage surfaces, respectively (P line knowledge for investigating the effects of various knee injuries on joint contact biomechanics and the aetiology of cartilage degeneration.

  4. Navigation for fluoroscopy-guided cryo-balloon ablation procedures of atrial fibrillation

    Science.gov (United States)

    Bourier, Felix; Brost, Alexander; Kleinoeder, Andreas; Kurzendorfer, Tanja; Koch, Martin; Kiraly, Attila; Schneider, Hans-Juergen; Hornegger, Joachim; Strobel, Norbert; Kurzidim, Klaus

    2012-02-01

    Atrial fibrillation (AFib), the most common arrhythmia, has been identified as a major cause of stroke. The current standard in interventional treatment of AFib is the pulmonary vein isolation (PVI). PVI is guided by fluoroscopy or non-fluoroscopic electro-anatomic mapping systems (EAMS). Either classic point-to-point radio-frequency (RF)- catheter ablation or so-called single-shot-devices like cryo-balloons are used to achieve electrically isolation of the pulmonary veins and the left atrium (LA). Fluoroscopy-based systems render overlay images from pre-operative 3-D data sets which are then merged with fluoroscopic imaging, thereby adding detailed 3-D information to conventional fluoroscopy. EAMS provide tracking and visualization of RF catheters by means of electro-magnetic tracking. Unfortunately, current navigation systems, fluoroscopy-based or EAMS, do not provide tools to localize and visualize single shot devices like cryo-balloon catheters in 3-D. We present a prototype software for fluoroscopy-guided ablation procedures that is capable of superimposing 3-D datasets as well as reconstructing cyro-balloon catheters in 3-D. The 3-D cyro-balloon reconstruction was evaluated on 9 clinical data sets, yielded a reprojected 2-D error of 1.72 mm +/- 1.02 mm.

  5. Palliative Airway Stenting Performed Under Radiological Guidance and Local Anesthesia

    International Nuclear Information System (INIS)

    Profili, Stefano; Manca, Antonio; Feo, Claudio F.; Padua, Guglielmo; Ortu, Riccardo; Canalis, Giulio C.; Meloni, Giovanni B.

    2007-01-01

    Purpose. To assess the effectiveness of airway stenting performed exclusively under radiological guidance for the palliation of malignant tracheobronchial strictures. Methods. We report our experience in 16 patients with malignant tracheobronchial stricture treated by insertion of 20 Ultraflex self-expandable metal stents performed under fluoroscopic guidance only. Three patients presented dysphagia grade IV due to esophageal malignant infiltration; they therefore underwent combined airway and esophageal stenting. All the procedures were performed under conscious sedation in the radiological room; average procedure time was around 10 min, but the airway impediment never lasted more than 40 sec. Results. We obtained an overall technical success in 16 cases (100%) and clinical success in 14 patients (88%). All prostheses were successfully placed without procedural complications. Rapid clinical improvement with symptom relief and normalization of respiratory function was obtained in 14 cases. Two patients died within 48 hr from causes unrelated to stent placement. Two cases (13%) of migration were observed; they were successfully treated with another stent. Tumor overgrowth developed in other 2 patients (13%); however, no further treatment was possible because of extensive laryngeal infiltration. Conclusions. Tracheobronchial recanalization with self-expandable metal stents is a safe and effective palliative treatment for malignant strictures. Airway stenting performed exclusively under fluoroscopic view was rapid and well tolerated

  6. Measurement of patient skin absorbed dose in ablation of paroxysmal atrial fibrillation, and examination of treatment protocol

    International Nuclear Information System (INIS)

    Shohji, Tomokazu; Hiramatsu, Masaki; Hasome, Hideki

    2005-01-01

    The ablation for atrial fibrillation minute movement done in our hospital is 250 minutes or less, within an average time of 150 minutes during a fluoroscopic time of about 7 hours, with very large average inspection times numerical values. However, the skin-absorbed dose could be understood only from the numerical value of the area dosimeter. It was considered that the total dose that reached the threshold was sufficient, although radiation injury would not be reported from the ablation currently done at our hospital. Therefore, we aimed to examine the inspection protocol in this hospital, and to request the patient be given an inspection dose that was the average skin-absorbed dose by using the acryl board. The amount of a total dose for an inspection of 150 minutes of fluoroscopic time was about 2.7 Gy. Moreover, a value of 1.5 Gy was indicated in the hot spot as a result of repetition in some exposure fields. However, it was thought that the possibility of exceeding the threshold of 2 Gy depending on the inspection situation in the future and other factors was tolerable because these measurements were done so as not to overvalue it more than the necessary. (author)

  7. Investigation of grid performance using simple image quality tests

    Directory of Open Access Journals (Sweden)

    Dogan Bor

    2016-01-01

    Full Text Available Antiscatter grids improve the X-ray image contrast at a cost of patient radiation doses. The choice of appropriate grid or its removal requires a good knowledge of grid characteristics, especially for pediatric digital imaging. The aim of this work is to understand the relation between grid performance parameters and some numerical image quality metrics for digital radiological examinations. The grid parameters such as bucky factor (BF, selectivity (Σ, Contrast improvement factor (CIF, and signal-to-noise improvement factor (SIF were determined following the measurements of primary, scatter, and total radiations with a digital fluoroscopic system for the thicknesses of 5, 10, 15, 20, and 25 cm polymethyl methacrylate blocks at the tube voltages of 70, 90, and 120 kVp. Image contrast for low- and high-contrast objects and high-contrast spatial resolution were measured with simple phantoms using the same scatter thicknesses and tube voltages. BF and SIF values were also calculated from the images obtained with and without grids. The correlation coefficients between BF values obtained using two approaches (grid parameters and image quality metrics were in good agreement. Proposed approach provides a quick and practical way of estimating grid performance for different digital fluoroscopic examinations.

  8. A Simple Technique for Shoulder Arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Berna-Serna, J.D.; Redondo, M.V.; Martinez, F.; Reus, M.; Alonso, J.; Parrilla, A.; Campos, P.A. [Virgen de la Arrixaca Univ. Hospital, El Palmar, Murcia (Spain). Dept. of Radiology

    2006-09-15

    Purpose: To present a systematic approach to teaching a technique for arthrography of the shoulder. Using an adhesive marker-plate with radiopaque coordinates, precise sites for puncture can be identified and the need for fluoroscopic guidance obviated. Material and Methods: Forty-six glenohumeral arthrograms were performed in 45 patients; in 1 case involving examination of both shoulders. The stages of the technique are described in detail, as are the fundamental aspects of achieving an effective glenohumeral injection. Pain intensity was measured in all patients using a verbal description scale. Results: Shoulder arthrography was successful in all cases. Average time taken for the procedure was 7 min, with no difference in the respective times required by an experienced radiologist and a resident. The procedure was well tolerated by most patients, with slight discomfort being observed in a very few cases. Conclusion: The arthrographic technique used in this study is simple, safe, rapid, and reproducible, and has the advantage of precise localization of the site for puncture without need for fluoroscopic guidance. The procedure described in this study can be of help in teaching residents and can reduce the learning curve for radiologists with no experience in arthrographic methods. It also reduces the time of exposure to fluoroscopy Keywords: Arthrography, joint, shoulder.

  9. Radiation dermatitis due to catheter ablation used in the treatment of arrhythmia. A report of two cases

    International Nuclear Information System (INIS)

    Nagano, Tohru; Kosaka, Hiroshi; Shimoura, Shinichi; Tsuru, Kenta; Yamagami, Nao; Ikeda, Tetsuya; Nishigori, Chikako; Yoshida, Akihiro

    2004-01-01

    We report 2 cases of radiation dermatitis caused by catheter ablation for treatment of atrial fibrillation resisitant to conventional therapies. Case 1, 50-year-old male underwent pulmonary veins ablation for treatment of atrial fibrillation. Cumulative fluoroscopic imaging time of 370 min was required. Case 2, 74-year-old female also underwent pulmonary veins ablation for treatment of atrial fibrillation. Cumulative fluoroscopic imaging time of 550 min was required. Since dose rate used for imaging is 20∼80 mGy/min, accumulated skin doses were estimated as 7.4∼29.6 Gy and 5.6∼22.4 Gy, respectively. Two weeks after their last ablation, brown, painful macule and plaque appeared on the outer side of their right upper arms. To our knowledge, the risk of overexposure to X-ray in cases of PTCA (percutaneous transluminal coronary angioplasty) for ischemic heart diseases has been well known, but little is known about the risk of catheter ablation. The location of radiation dermatitis caused by catheter ablation (CA) is rather different from that of PTCA. It is critical for cardiologists and dermatologists to observe and find the symptoms of acute radiation dermatitis in order to avoid repeated overexposure to X-ray. (author)

  10. Treatment of pathologic spinal fractures with combined radiofrequency ablation and balloon kyphoplasty

    Directory of Open Access Journals (Sweden)

    Tzanakakis George

    2009-11-01

    Full Text Available Abstract Background In oncologic patients with metastatic spinal disease, the ideal treatment should be well tolerated, relieve the pain, and preserve or restore the neurological function. The combination of fluoroscopic guided radiofrequency ablation (RFA and kyphoplasty may fulfill these criteria. Methods We describe three pathological vertebral fractures treated with a combination of fluoroscopic guided RFA and kyphoplasty in one session: a 62-year-old man suffering from a painful L4 pathological fracture due to a plasmocytoma, a 68-year-old man with a T12 pathological fracture from metastatic hepatocellular carcinoma, and a 71-year-old man with a Th12 and L1 pathological fracture from multiple myeloma. Results The choice of patients was carried out according to the classification of Tomita. Visual analog score (VAS and Oswestry disability index (ODI were used for the evaluation of the functional outcomes. The treatment was successful in all patients and no complications were reported. The mean follow-up was 6 months. Marked pain relief and functional restoration was observed. Conclusion In our experience the treatment of pathologic spinal fractures with combined radiofrequency ablation and balloon kyphoplasty is safe and effective for immediate pain relief in painful spinal lesions in neurologically intact patients.

  11. A novel removable shield attached to C-arm units against scattered X-rays from a patient's side

    Energy Technology Data Exchange (ETDEWEB)

    Mori, Hiroshige [Hokkaido Social Insurance Hospital, Department of Radiology, Sapporo, Hokkaido (Japan); Kanazawa University, Department of Quantum Medical Technology, Division of Health Sciences, Graduate School of Medical Science, Kanazawa, Ishikawa (Japan); Koshida, Kichiro; Matsubara, Kosuke [Kanazawa University, School of Health Sciences, College of Medical, Pharmaceutical and Health Sciences, Kanazawa, Ishikawa (Japan); Ishigamori, Osamu [Hokkaido Social Insurance Hospital, Department of Radiology, Sapporo, Hokkaido (Japan)

    2014-08-15

    We invented a drape-like shield against scattered X-rays that can safely come into contact with medical equipment or people during fluoroscopically guided procedures. The shield can be easily removed from a C-arm unit using one hand. We evaluated the use of the novel removable shield during the endoscopic retrograde cholangiopancreatography (ERCP) procedure. We measured the dose rate of scattered X-rays around endoscopists with and without this removable shield and surveyed the occupational doses to the ERCP staff. We also examined the endurance of the shield. The removable shield reduced the dose rate of scattered X-rays to one-tenth and reduced the monthly dose to an endoscopist by at least two-fifths. For 2.5 years, there was no damage to the shield and no loosening of the seam. The bonding of the hook-and-loop fasteners did not weaken, although the powerful double-sided tapes made especially for plastic did. The removable shield can reduce radiation exposure to the ERCP staff and may contribute to reducing the exposure to the eye lenses of operators. It would also be possible to expand its use to other fluoroscopically guided procedures besides ERCP because it is a light, simple, and useful device. (orig.)

  12. The value of flat-detector computed tomography during catheterisation of congenital heart disease

    International Nuclear Information System (INIS)

    Gloeckler, Martin; Koch, Andreas; Greim, Verena; Shabaiek, Amira; Dittrich, Sven; Rueffer, Andre; Cesnjevar, Robert; Achenbach, Stephan

    2011-01-01

    To analyse the diagnostic utility of flat-detector computed tomography imaging (FD-CT) in patients with congenital heart disease, including the value of image fusion to overlay three-dimensional (3D) reconstructions on fluoroscopic images during catheter-based interventions. We retrospectively analysed 62 consecutive paediatric patients in whom FD-CT was used during catheterisation of congenital heart disease. Expert operators rated the clinical value of FD-CT over conventional fluoroscopic imaging. Added radiation exposure and contrast medium volume were evaluated. During a 12-month period, FD-CT was performed in 62 out of 303 cardiac catheterisations. Median patient age was 3.5 years. In 32/62 cases, FD-CT was used for diagnostic purposes, in 30/62 cases it was used in the context of interventions. Diagnostic utility was never rated as ''misleading''. It was classified as ''not useful'' in six cases (9.7%), ''useful'' in 18 cases (29.0%), ''very useful'' in 37 cases (59.7%) and ''essential'' in one case (1.6%). The median added dose-area product was 111.0 μGym 2 , the required additional quantity of contrast medium was 1.6 ml/kg. FD-CT provides useful diagnostic information in most of the patients investigated for congenital heart disease. The added radiation exposure and contrast medium volume are reasonable. (orig.)

  13. Megaesophagus in two cats.

    Science.gov (United States)

    Hoenig, M; Mahaffey, M B; Parnell, P G; Styles, M E

    1990-03-01

    Megaesophagus was diagnosed in 2 cats. Both had a history of regurgitation, and one was dyspneic. Radiography of the thorax and abdomen revealed generalized megaesophagus and gastric distention with gas. There was no esophageal motility during fluoroscopic observation. The prognosis for cats with megaesophagus is guarded. Although they may be satisfactory pets, cats with this condition should not be used for breeding because the condition is believed to be inherited through recessive genes.

  14. Modern instrumentation for radiation introscopic testing of welding quality

    International Nuclear Information System (INIS)

    Sosnin, F.R.

    1985-01-01

    Modern instrumenlation used for radiation introscopy of welded joints is discussed. the absolute (relative) sensitivity of radiation testing, resolution range, efficiency are considered as basic parameters of introscopes. The characteristics of fluoroscopes, radiation-television installations with the external scintillator and radiative image converter as well as with X-ray vidicons are given. The characterisitcs of radiation introscopes with manipulators to move objects being tested are analysed as well as digitized radiation introscopes

  15. A mutant with riboflavin productivity obtained from non-riboflavin-producing ashbya gossypii by γ-induction

    International Nuclear Information System (INIS)

    Yang Suhong; Ge Zhongliang

    1993-01-01

    60 Co γ-ray was used to irradiate Ashbya gossypii, which does not produce riboflavin originally, and mutants were obtained with colonial colour changing from white into yellow. Mutant ratio was high at the absorption dose of 90 Gy. Results of reverse phase-HPLC, high performance-TLC and fluoroscopic analysis proved that riboflavin is produced by the mutant fermentation. The mutant remained after generations of culture, indicating that the induced new properties are stably inheritable

  16. Automatic Image Alignment and Stitching of Medical Images with Seam Blending

    OpenAIRE

    Abhinav Kumar; Raja Sekhar Bandaru; B Madhusudan Rao; Saket Kulkarni; Nilesh Ghatpande

    2010-01-01

    This paper proposes an algorithm which automatically aligns and stitches the component medical images (fluoroscopic) with varying degrees of overlap into a single composite image. The alignment method is based on similarity measure between the component images. As applied here the technique is intensity based rather than feature based. It works well in domains where feature based methods have difficulty, yet more robust than traditional correlation. Component images are stitched together usin...

  17. X-ray spot film device

    International Nuclear Information System (INIS)

    1981-01-01

    Improvements are described in an X-ray spot film device which is used in conjunction with an X-ray table to make a selected number of radiographic exposures on a single film and to perform fluoroscopic examinations. To date, the spot film devices consist of two X-ray field defining masks, one of which is moved manually. The present device is more convenient to use and speeds up the procedure. (U.K.)

  18. A new adjustable parallel drill guide for internal fixation of femoral neck fracture: a developmental and experimental study

    OpenAIRE

    Yuenyongviwat, Varah; Tuntarattanapong, Pakjai; Tangtrakulwanich, Boonsin

    2016-01-01

    Background Internal fixation is one treatment for femoral neck fracture. Some devices and techniques reported improved accuracy and decreased fluoroscopic time. However, these are not widely used nowadays due to the lack of available special instruments and techniques. To improve the surgical procedure, the authors designed a new adjustable drill guide and tested the efficacy of the device. Methods The authors developed a new adjustable drill guide for cannulated screw guide wire insertion fo...

  19. Radiation protection in the operating room

    International Nuclear Information System (INIS)

    Kunz, B.; Stargardt, A.

    1978-01-01

    On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low

  20. Importance of radiographic monitoring of endoscopic sphincterotomy

    International Nuclear Information System (INIS)

    Greenberg, H.M.; Goldberg, H.I.; Shapiro, H.A.

    1981-01-01

    The radiographic features of endoscopic sphincterotomies performed in 44 patients were evaluated. Radiographic landmarks aided in proper sphincterotome placement and also disclosed conditions and anatomic variations that made catheter placement difficult. Fluoroscopic and radiographic monitoring not only assisted the performance of endoscopic sphincterotomy, but also confirmed successful results and revealed reasons for failure. Radiographic changes in the biliary tract after sphincterotomy, as well as potential complications of sphincterotomy, are discussed and illustrated

  1. SU-F-J-137: Intrafractional Change of the Relationship Between Internal Fiducials and External Breathing Signal in Pancreatic Cancer Stereotactic Body Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Pettersson, N; Murphy, J; Simpson, D; Cervino, L [University of California, San Diego, La Jolla, CA (United States)

    2016-06-15

    Purpose: The use of respiratory gating for management of breathing motion during stereotactic body radiation therapy (SBRT) relies on a consistent relationship between the breathing signal and the actual position of the internal target. This relationship was investigated in patients treated for pancreatic cancer. Methods: Four patients with pancreatic cancer undergoing SBRT that had implanted fiducials in the tumor were included in this study. Treatment plans were generated based on the exhale phases (30–70%) from the pre-treatment 4DCT. The margin between the internal target volume (ITV) and the planning target volume was three mm. After patient setup using cone-beam CT, simultaneous fluoroscopic imaging and breathing motion monitoring were used during at least three breathing cycles to verify the fiducial position and to optimize the gating window. After treatment, fluoroscopic images were acquired for verification purposes and exported for retrospective analyses. Fiducial positions were determined using a template-matching algorithm. For each dataset, we established a linear relationship between the fiducial position and the anterior-posterior (AP) breathing signal. The relationships before and after treatment were compared and the dose distribution impact evaluated. Results: Seven pre- and post-treatment fluoroscopic pairs were available for fiducial position analyses in the superior-inferior (SI) and left-right (LR) directions, and five in the AP direction. Time between image acquisitions was typically six to eight minutes. An average absolute change of 1.2±0.7 mm (range: 0.1–1.7) of the SI fiducial position relative to the external signal was found. Corresponding numbers for the LR and AP fiducial positions were 0.9±1.0 mm (range: 0.2–3.0) and 0.5±0.4 mm (range: 0.2–1.2), respectively. The dose distribution impact was small in both the ITV and organs-at-risk. Conclusion: The relationship change between fiducial position and external breathing

  2. SU-F-J-137: Intrafractional Change of the Relationship Between Internal Fiducials and External Breathing Signal in Pancreatic Cancer Stereotactic Body Radiation Therapy

    International Nuclear Information System (INIS)

    Pettersson, N; Murphy, J; Simpson, D; Cervino, L

    2016-01-01

    Purpose: The use of respiratory gating for management of breathing motion during stereotactic body radiation therapy (SBRT) relies on a consistent relationship between the breathing signal and the actual position of the internal target. This relationship was investigated in patients treated for pancreatic cancer. Methods: Four patients with pancreatic cancer undergoing SBRT that had implanted fiducials in the tumor were included in this study. Treatment plans were generated based on the exhale phases (30–70%) from the pre-treatment 4DCT. The margin between the internal target volume (ITV) and the planning target volume was three mm. After patient setup using cone-beam CT, simultaneous fluoroscopic imaging and breathing motion monitoring were used during at least three breathing cycles to verify the fiducial position and to optimize the gating window. After treatment, fluoroscopic images were acquired for verification purposes and exported for retrospective analyses. Fiducial positions were determined using a template-matching algorithm. For each dataset, we established a linear relationship between the fiducial position and the anterior-posterior (AP) breathing signal. The relationships before and after treatment were compared and the dose distribution impact evaluated. Results: Seven pre- and post-treatment fluoroscopic pairs were available for fiducial position analyses in the superior-inferior (SI) and left-right (LR) directions, and five in the AP direction. Time between image acquisitions was typically six to eight minutes. An average absolute change of 1.2±0.7 mm (range: 0.1–1.7) of the SI fiducial position relative to the external signal was found. Corresponding numbers for the LR and AP fiducial positions were 0.9±1.0 mm (range: 0.2–3.0) and 0.5±0.4 mm (range: 0.2–1.2), respectively. The dose distribution impact was small in both the ITV and organs-at-risk. Conclusion: The relationship change between fiducial position and external breathing

  3. SU-E-J-56: Static Gantry Digital Tomosynthesis From the Beam’s-Eye-View

    International Nuclear Information System (INIS)

    Partain, L; Kwon, J; Boyd, D; Rottmann, J; Berbeco, R; Zentai, G

    2015-01-01

    Purpose We have designed a novel TumoTrak™ x-ray system that delivers 19 distinct kV views with the linac gantry stationary. It images MV treatment beam above and below the patient with a kV tomosysthesis slice image from the therapy beam’s-eye-view. Results will be high quality images without MLC shadowing for notable improvements relative to conventional fluoroscopic MV imaging and fluoroscopic kV imaging. Methods A complete design has a kV electron beam multisource X-ray tube that fits around the MV treatment beam path, with little interference with normal radiotherapy and unblocked by the multi-leaf-collimator. To simulate digital tomosynthesis, we used cone-beam CT projection data from a lung SBRT patient. These data were acquired at 125 kVp and 11 fps (0.4 mAs per projection). We chose 19 projections evenly spaced over 27° around one of the treatment angles (240°). Digital tomosynthesis reconstruction of a slice through the tumor was performed using iterative reconstruction. The visibility of the lesion was assessed for the reconstructed digital tomosynthesis (DTS), using fluoroscopy MV images acquired during radiation therapy, and a kV single projection image acquired at the same angle as the treatment field (240°). Results The fluoroscopic DTS images provide the best tumor contrast, surpassing the conventional radiographic and the in-treatment MV portal images. The electron beam multisource X-ray tube design has been completed and the tube is being fabricated. The estimated time to cycle through all 19 projections is 700 ms, enabling high frame-rate imaging. While the initial proposed use case is for image guided and gated treatment delivery, the enhanced imaging will also deliver superior radiographic images for patient setup. Conclusion The proposed device will deliver high quality planar images from the beam’s-eye-view without MLC obstruction. The prototype has been designed and is being assembled with first imaging scheduled for May 2015. L

  4. SU-E-J-56: Static Gantry Digital Tomosynthesis From the Beam’s-Eye-View

    Energy Technology Data Exchange (ETDEWEB)

    Partain, L; Kwon, J; Boyd, D [TeleSecurity Sciences, Las Vegas, NV (United States); Rottmann, J; Berbeco, R [Brigham and Woman’s Hospital, Boston, MA (United States); Zentai, G [Varian Medical Systems, Palo Alto, CA (United States)

    2015-06-15

    Purpose We have designed a novel TumoTrak™ x-ray system that delivers 19 distinct kV views with the linac gantry stationary. It images MV treatment beam above and below the patient with a kV tomosysthesis slice image from the therapy beam’s-eye-view. Results will be high quality images without MLC shadowing for notable improvements relative to conventional fluoroscopic MV imaging and fluoroscopic kV imaging. Methods A complete design has a kV electron beam multisource X-ray tube that fits around the MV treatment beam path, with little interference with normal radiotherapy and unblocked by the multi-leaf-collimator. To simulate digital tomosynthesis, we used cone-beam CT projection data from a lung SBRT patient. These data were acquired at 125 kVp and 11 fps (0.4 mAs per projection). We chose 19 projections evenly spaced over 27° around one of the treatment angles (240°). Digital tomosynthesis reconstruction of a slice through the tumor was performed using iterative reconstruction. The visibility of the lesion was assessed for the reconstructed digital tomosynthesis (DTS), using fluoroscopy MV images acquired during radiation therapy, and a kV single projection image acquired at the same angle as the treatment field (240°). Results The fluoroscopic DTS images provide the best tumor contrast, surpassing the conventional radiographic and the in-treatment MV portal images. The electron beam multisource X-ray tube design has been completed and the tube is being fabricated. The estimated time to cycle through all 19 projections is 700 ms, enabling high frame-rate imaging. While the initial proposed use case is for image guided and gated treatment delivery, the enhanced imaging will also deliver superior radiographic images for patient setup. Conclusion The proposed device will deliver high quality planar images from the beam’s-eye-view without MLC obstruction. The prototype has been designed and is being assembled with first imaging scheduled for May 2015. L

  5. Plasma-mediated radiofrequency ablation followed by percutaneous cementoplasty under fluoro-CT guidance: a case report

    OpenAIRE

    Carrafiello, Gianpaolo; Lagan?, Domenico; Ianniello, Andrea; Fontana, Federico; Mangini, Monica; Mocciardini, Lucia; Span?, Emanuela; Piacentino, Filippo; Cuffari, Salvatore; Fugazzola, Carlo

    2009-01-01

    We report a case of a 81-year-old Caucasian man with colorectal carcinoma, treated by surgery in 1998, referred for palliative treatment of a refractory painful caused by osteolytic metastases of 2.5 cm in back-upper ilium spine. Plasma-mediated radiofrequency ablation was performed under conscious sedation, using Fluoroscopic Computer Tomography guidance. After completing the ablation phase of the procedure, a mixture of bone cement and Biotrace sterile barium sulfate was injected into the a...

  6. Development of low-cost digital subtraction angiography system

    International Nuclear Information System (INIS)

    Ando, Yutaka; Kobayashi, Takeshi; Imai, Yutaka; Yagishita, Akira; Kunieda, Etsuo.

    1983-01-01

    We developed a simple and low-cost DSA system. This system consists of a conventional fluoroscopic equipment for the GI tract and a mini-computer (GAMMA-11) which are connected each other with a video-disc recorder. The uniqueness of our system are 1. low-cost, 2. low-radiation dose, 3. off-line processing, 4. flexibility of software. The analysis of the time-density curve and image processing will bring us a more usefull information than DSA alone. (author)

  7. Asymptomatic Strut Fracture in DeBakey-Surgitool Aortic Valves: Incidence, Management, and Metallurgic Aspects

    OpenAIRE

    Von Der Emde, Jürgen; Eberlein, Ulrich; Breme, Jürgen

    1990-01-01

    From August 1971 through November 1972, we implanted 62 Model 2 DeBakey-Surgitool aortic valve prostheses in 62 patients, 4 of whom later had clinically asymptomatic strut fractures. In 1 case, the patient died suddenly, and autopsy revealed detachment of the ball-cage; in each of the other 3 cases, fractures of 2 struts close to the base of the prosthesis were diagnosed fluoroscopically, and the patients underwent successful reoperation. The interval between implantation and reoperation rang...

  8. Image guidance in trans-sphenoidal surgery for giant pituitary adenomas: Luxury or necessity?

    OpenAIRE

    Deepak Agrawal

    2012-01-01

    Background: In spite of availability of image guidance (neuronavigation) at major centers around the world, most trans-sphenoidal surgeries for pituitary adenomas continue to be done under fluoroscopic control. On the other hand, the high mortality and morbidity for giant pituitary adenomas is mainly due to inadequate tumor removal. Aims and Objectives: The objective of this study was to study to utility of image guidance in trans-sphenoidal surgeries for optimizing tumor removal in giant pit...

  9. A prototype percutaneous transhepatic cholangiography training simulator with real-time breathing motion.

    Science.gov (United States)

    Villard, P F; Vidal, F P; Hunt, C; Bello, F; John, N W; Johnson, S; Gould, D A

    2009-11-01

    We present here a simulator for interventional radiology focusing on percutaneous transhepatic cholangiography (PTC). This procedure consists of inserting a needle into the biliary tree using fluoroscopy for guidance. The requirements of the simulator have been driven by a task analysis. The three main components have been identified: the respiration, the real-time X-ray display (fluoroscopy) and the haptic rendering (sense of touch). The framework for modelling the respiratory motion is based on kinematics laws and on the Chainmail algorithm. The fluoroscopic simulation is performed on the graphic card and makes use of the Beer-Lambert law to compute the X-ray attenuation. Finally, the haptic rendering is integrated to the virtual environment and takes into account the soft-tissue reaction force feedback and maintenance of the initial direction of the needle during the insertion. Five training scenarios have been created using patient-specific data. Each of these provides the user with variable breathing behaviour, fluoroscopic display tuneable to any device parameters and needle force feedback. A detailed task analysis has been used to design and build the PTC simulator described in this paper. The simulator includes real-time respiratory motion with two independent parameters (rib kinematics and diaphragm action), on-line fluoroscopy implemented on the Graphics Processing Unit and haptic feedback to feel the soft-tissue behaviour of the organs during the needle insertion.

  10. Exposure of the orthopaedic surgeon to radiation

    Energy Technology Data Exchange (ETDEWEB)

    Katoh, Kiyonobu; Koga, Takamasa; Matsuzaki, Akio; Kido, Masaki; Satoh, Tetsunori [Fukuoka Univ. (Japan). Chikushi Hospital

    1995-09-01

    We monitored the amount of radiation received by surgeons and assistants during surgery carried out with fluoroscopic assistance. The radiation was monitored with the use of MYDOSE MINIX PDM107 made by Aloka Co. Over a one year period from Aug 20, 1992 to Aug 19, 1993, a study was undertaken to evaluate exposure of the groin level to radiation with or without use of the lead apron during 106 operation (Group-1). In another group, radiation was monitored at the breast and groin level outside of the lead apron during 39 operations (Group-2). In Group-1, the average exposure per person during one year was 46.0 {mu}SV and the average exposure for each procedure was 1.68 {mu}SV. The use of the lead apron affirmed its protective value; the average radiation dose at the groin level out-side of the apron was 9.11 {mu}SV, the measured dose beneath the apron 0.61 {mu}SV. The average dose of exposure to the head, breast at groin level outside of the lead apron, were 7.68 {mu}SV, 16.24 {mu}SV, 32.04 {mu}SV respectively. This study and review of the literature indicate that the total amount of radiation exposure during surgery done with fluoroscopic control remains well within maximum exposure limits. (author).

  11. Exposure of the orthopaedic surgeon to radiation

    International Nuclear Information System (INIS)

    Katoh, Kiyonobu; Koga, Takamasa; Matsuzaki, Akio; Kido, Masaki; Satoh, Tetsunori

    1995-01-01

    We monitored the amount of radiation received by surgeons and assistants during surgery carried out with fluoroscopic assistance. The radiation was monitored with the use of MYDOSE MINIX PDM107 made by Aloka Co. Over a one year period from Aug 20, 1992 to Aug 19, 1993, a study was undertaken to evaluate exposure of the groin level to radiation with or without use of the lead apron during 106 operation (Group-1). In another group, radiation was monitored at the breast and groin level outside of the lead apron during 39 operations (Group-2). In Group-1, the average exposure per person during one year was 46.0 μSV and the average exposure for each procedure was 1.68 μSV. The use of the lead apron affirmed its protective value; the average radiation dose at the groin level out-side of the apron was 9.11 μSV, the measured dose beneath the apron 0.61 μSV. The average dose of exposure to the head, breast at groin level outside of the lead apron, were 7.68 μSV, 16.24 μSV, 32.04 μSV respectively. This study and review of the literature indicate that the total amount of radiation exposure during surgery done with fluoroscopic control remains well within maximum exposure limits. (author)

  12. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo; Matsumoto, Tomohiro; Hasebe, Terumitsu; Kakizawa, Hideaki; Toyoda, Naoyuki

    2014-01-01

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  13. Management of Hip Fractures in Lateral Position without a Fracture Table

    Directory of Open Access Journals (Sweden)

    Hamid Pahlavanhosseini

    2014-09-01

    Full Text Available Background:  Hip fracture Management in supine position on a fracture table with biplane fluoroscopic views has some difficulties which leads to prolongation of surgery and increasing x- rays’ dosage. The purpose of this study was to report the results and complications of hip fracture management in lateral position on a conventional operating table with just anteroposterior fluoroscopic view.  Methods:  40 hip fractures (31 trochanteric and 9 femoral neck fractures were operated in lateral position between Feb 2006 and Oct 2012. Age, gender, fracture classification, operation time, intra-operation blood loss, reduction quality, and complications were extracted from patients’ medical records. The mean follow-up time was 30.78±22.73 months (range 4-83. Results: The mean operation time was 76.50 ± 16.88 min (range 50 – 120 min.The mean intra-operative blood loss was 628.75 ± 275.00 ml (range 250-1300ml. Anatomic and acceptable reduction was observed in 95%of cases. The most important complications were malunion (one case in trochanteric group, avascular necrosis of oral head and nonunion (each one case in femoral neck group.  Conclusions:  It sounds that reduction and fixation of hip fractures in lateral position with fluoroscopy in just anteroposterior view for small rural hospitals may be executable and probably safe.

  14. US-guided percutaneous transhepatic biliary drainage: comparative study of right-sided and left-sided approach

    International Nuclear Information System (INIS)

    Kim, Young Hwan; Cha, Soon Joo

    2002-01-01

    To compare the feasibility and safety of US-guided right and left percutaneous transhepatic biliary drainage (PTBD). Between March 1998 and May 1999, 32 patients underwent 36 US-guided right or left PTBD in referred order, alternatively. The causes of biliary obstruction were bile duct stone (n=2), bile duct carcinoma (n=10), carcinoma of the pancreas (n=9), GB carcinoma (n=7), metastasis to the porta hepatis (n=3), and carcinoma of the ampulla of vater (n=1). Technical success, procedure time, fluoroscopic time, and complications were evaluated. PTBD was successful in 94% of both right and left approach. The average procedure time was 9.7 ±3.8 min. in the right approach and 9.6 ±3.1 min. in the left approach, respectively (p=0.794). The average fluoroscopic time were 3.9±2.4 min. in the right approach and 3.8±2.2 min. in the left approach (p=0.892). A major complication, bile peritonitis, occurred in one of 16 patient with right-sided approach. Minor complications occurred in six right (2 hemobilia, 3 tube malfunction, 1 cholangitis) and three left (1 hemobilia, 1 fever, 1cholangitis) PTBD. There were no significant difference in the complication rates between right and left PTBD (p=0.729). There were no significant differences in feasibility and safety in US-guided right and left PTBD

  15. Effectiveness of combined use of imprint cytological and histological examination in CT-guided tissue-core biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Yamagami, Takuji; Yoshimatsu, Rika; Kajiwara, Kenji; Ishikawa, Masaki; Awai, Kazuo [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Matsumoto, Tomohiro; Hasebe, Terumitsu [Tokai University Hachioji Hospital, Tokai University School of Medicine, Department of Radiology, Hachioji, Tokyo (Japan); Kakizawa, Hideaki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); Hiroshima Red Cross Hospital and Atomic-bomb Survivors Hospital, Department of Diagnostic Radiology, Naka-Ku, Hiroshima (Japan); Toyoda, Naoyuki [Hiroshima University, Department of Diagnostic Radiology, Institute and Graduate School of Biomedical Sciences, Minami-Ku, Hiroshima (Japan); National Hospital Organisation Kure Medical Centre, Department of Diagnostic Radiology, Kure, Hiroshima (Japan)

    2014-05-15

    This study evaluated the efficacy of the combination of imprint cytology and histology in tissue-core percutaneous biopsy under real-time computed tomography (CT) fluoroscopic guidance. Between October 2009 and June 2013, 156 percutaneous needle biopsies were performed in our institution. Those obtained by tissue-core biopsy underwent both imprint cytological and histological examinations routinely after touch imprint cytology was performed on site to evaluate the samples' sufficiency for cytological and pathological examination. Final diagnosis was confirmed by independent surgical pathology, independent culture results or clinical follow-up. Rates of adequate specimens and precise diagnosis, by combined cytological and histological examination were 100 % (156/156) and 96.2 % (150/156), by cytology 94.4 % (152/156) and 83.3 % (130/156) and by histology 99.3 % (155/156) and 92.3 % (144/156). Precise diagnosis was achieved by combined examinations in 94.7 % (89/94) of thoracic lesions, 97.6 % (40/41) of musculoskeletal lesions, and 100 % (21/21) of abdominal, pelvic and retroperitoneal lesions. In all 104 lesions diagnosed as malignant by CT-guided biopsy and in 30 of 52 diagnosed as benign, specific cell types could be proved by combined examinations. Combined imprint cytology and histology performed after on-site touch imprint cytological evaluation improved the diagnostic ability of CT fluoroscopically guided biopsy. (orig.)

  16. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Takenaka, Daisuke; Imai, Masatake; Ohbayashi, Chiho; Sugimura, Kazuro

    2004-01-01

    Objective: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. Materials and methods: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. Results: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P<0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P<0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P<0.05). Conclusion: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time

  17. Fluoroscopy-guided intrA-articular facet joint steroid injection for the management of low back pain: Therapeutic effectiveness and arthrographic pattern

    International Nuclear Information System (INIS)

    Kim, Su Jin; Lee, Jun Woo; Lee, Guen Young; You, Ja Yeon; Kang, Heung Sik; Chai, Jae Won; Ahn, Joong Mo

    2015-01-01

    To evaluate the effectiveness of fluoroscopy-guided intra-articular facet joint steroid injection for the management of low back pain, and to document the incidence of epidural leakage. In total, 320 facet joint injections of 244 consecutive patients were included in this study. All patients had undergone an intra-articular facet joint steroid injection in 2007 and had follow-up post-treatment medical records. The response to treatment was analyzed on the basis of chart documentation (aggravated, no change, slightly improved, much improved, no pain). Fluoroscopic arthrograms of the injections were retrospectively analyzed by two radiologists. Of the 244 patients, 85.2% (n = 208) showed improvement after an initial intra-articular facet joint steroid injection. A total of 77.9% (n = 162) of the patients showed symptom recurrence, with a median of a 69 day symptom-free interval, while 30.3% (n = 74) of the patients showed symptom-free intervals of more than six months. Overall, 74 (33.3%) of the 222 cases of intra-articular facet joint steroid injections without concomitant epidural steroid injection showed epidural leakage in fluoroscopic arthrograms. Fluoroscopy-guided intra-articular facet joint injection is a reliable technique for the management of low back pain, with excellent immediate effectiveness and good prolonged (> 2 months) pain relief. Epidural leakage during injection was detected in one-third of the cases

  18. Low noise signal-to-noise ratio enhancing readout circuit for current-mediated active pixel sensors

    International Nuclear Information System (INIS)

    Ottaviani, Tony; Karim, Karim S.; Nathan, Arokia; Rowlands, John A.

    2006-01-01

    Diagnostic digital fluoroscopic applications continuously expose patients to low doses of x-ray radiation, posing a challenge to both the digital imaging pixel and readout electronics when amplifying small signal x-ray inputs. Traditional switch-based amorphous silicon imaging solutions, for instance, have produced poor signal-to-noise ratios (SNRs) at low exposure levels owing to noise sources from the pixel readout circuitry. Current-mediated amorphous silicon pixels are an improvement over conventional pixel amplifiers with an enhanced SNR across the same low-exposure range, but whose output also becomes nonlinear with increasing dosage. A low-noise SNR enhancing readout circuit has been developed that enhances the charge gain of the current-mediated active pixel sensor (C-APS). The solution takes advantage of the current-mediated approach, primarily integrating the signal input at the desired frequency necessary for large-area imaging, while adding minimal noise to the signal readout. Experimental data indicates that the readout circuit can detect pixel outputs over a large bandwidth suitable for real-time digital diagnostic x-ray fluoroscopy. Results from hardware testing indicate that the minimum achievable C-APS output current that can be discerned at the digital fluoroscopic output from the enhanced SNR readout circuit is 0.341 nA. The results serve to highlight the applicability of amorphous silicon current-mediated pixel amplifiers for large-area flat panel x-ray imagers

  19. The role of sacroiliac joint dysfunction in the genesis of low back pain: the obvious is not always right.

    Science.gov (United States)

    Weksler, Natan; Velan, Gad J; Semionov, Michael; Gurevitch, Boris; Klein, Moti; Rozentsveig, Vsevolod; Rudich, Tzvia

    2007-12-01

    It is a common practice to the link low back pain with protruding disc even when neurological signs are absent. Because pain caused by sacroiliac joint dysfunction can mimic discogenic or radicular low back pain, we assumed that the diagnosis of sacroiliac joint dysfunction is frequently overlooked. To assess the incidence of sacroiliac joint dysfunction in patients with low back pain and positive disc findings on CT scan or MRI, but without claudication or objective neurological deficits. Fifty patients with low back pain and disc herniation, without claudication or neurological abnormalities such as decreased motor strength, sensory alterations or sphincter incontinence and with positive pain provocation tests for sacroiliac joint dysfunction were submitted to fluoroscopic diagnostic sacroiliac joint infiltration. The mean baseline VAS pain score was 7.8 +/- 1.77 (range 5-10). Thirty minutes after infiltration, the mean VAS score was 1.3 +/- 1.76 (median 0.000E+00 with an average deviation from median = 1.30) (P = 0.0002). Forty-six patients had a VAS score ranging from 0 to 3, 8 weeks after the fluoroscopic guided infiltration. There were no serious complications after treatment. An unanticipated motor block that required hospitalization was seen in four patients, lasting from 12 to 36 h. Sacroiliac joint dysfunction should be considered strongly in the differential diagnosis of low back pain in this group of patients.

  20. Fluoroscopy-guided intrA-articular facet joint steroid injection for the management of low back pain: Therapeutic effectiveness and arthrographic pattern

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Su Jin; Lee, Jun Woo; Lee, Guen Young; You, Ja Yeon; Kang, Heung Sik [Dept. of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam (Korea, Republic of); Chai, Jae Won [Dept. of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); Ahn, Joong Mo [Dept. of Radiology, University of Pittsburgh Medical Center, Pittsburgh (United States)

    2015-09-15

    To evaluate the effectiveness of fluoroscopy-guided intra-articular facet joint steroid injection for the management of low back pain, and to document the incidence of epidural leakage. In total, 320 facet joint injections of 244 consecutive patients were included in this study. All patients had undergone an intra-articular facet joint steroid injection in 2007 and had follow-up post-treatment medical records. The response to treatment was analyzed on the basis of chart documentation (aggravated, no change, slightly improved, much improved, no pain). Fluoroscopic arthrograms of the injections were retrospectively analyzed by two radiologists. Of the 244 patients, 85.2% (n = 208) showed improvement after an initial intra-articular facet joint steroid injection. A total of 77.9% (n = 162) of the patients showed symptom recurrence, with a median of a 69 day symptom-free interval, while 30.3% (n = 74) of the patients showed symptom-free intervals of more than six months. Overall, 74 (33.3%) of the 222 cases of intra-articular facet joint steroid injections without concomitant epidural steroid injection showed epidural leakage in fluoroscopic arthrograms. Fluoroscopy-guided intra-articular facet joint injection is a reliable technique for the management of low back pain, with excellent immediate effectiveness and good prolonged (> 2 months) pain relief. Epidural leakage during injection was detected in one-third of the cases.

  1. US-guided percutaneous transhepatic biliary drainage: comparative study of right-sided and left-sided approach

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hwan; Cha, Soon Joo [College of Medicine, Inje Univ., Kimhae (Korea, Republic of)

    2002-02-01

    To compare the feasibility and safety of US-guided right and left percutaneous transhepatic biliary drainage (PTBD). Between March 1998 and May 1999, 32 patients underwent 36 US-guided right or left PTBD in referred order, alternatively. The causes of biliary obstruction were bile duct stone (n=2), bile duct carcinoma (n=10), carcinoma of the pancreas (n=9), GB carcinoma (n=7), metastasis to the porta hepatis (n=3), and carcinoma of the ampulla of vater (n=1). Technical success, procedure time, fluoroscopic time, and complications were evaluated. PTBD was successful in 94% of both right and left approach. The average procedure time was 9.7 {+-}3.8 min. in the right approach and 9.6 {+-}3.1 min. in the left approach, respectively (p=0.794). The average fluoroscopic time were 3.9{+-}2.4 min. in the right approach and 3.8{+-}2.2 min. in the left approach (p=0.892). A major complication, bile peritonitis, occurred in one of 16 patient with right-sided approach. Minor complications occurred in six right (2 hemobilia, 3 tube malfunction, 1 cholangitis) and three left (1 hemobilia, 1 fever, 1cholangitis) PTBD. There were no significant difference in the complication rates between right and left PTBD (p=0.729). There were no significant differences in feasibility and safety in US-guided right and left PTBD.

  2. A very feasible alternative in patients with feeding difficulties from gastrostomy: Jejunal tube advanced through the gastrostomy

    Directory of Open Access Journals (Sweden)

    Ramazan Karabulut

    2015-01-01

    Full Text Available Background: Our aim is to share our experiences regarding patients who cannot be fed effectively through the gastrostomy tube, but were inserted feeding jejunostomy through the gastrostomy orifice using scopic fluoroscopic techniques utilised by the interventional radiology. Patients and Methods: Between January 2010 and May 2013 the patients that were inserted jejunostomy tube through the gastrostomy orifice using fluoroscopic techniques were retrospectively analysed. Data including primary indication for gastrostomy, sex, concomitant disease and the requirement for gastroesophageal reflux disease (GERD were all recorded. Results: There were five patients with these criteria. They all received either medical or surgical GERD therapy; nevertheless enteral feeding failed to reach an effective level, they all had vomiting and did not gain any weight. Following conversion, all the patients gained minimum 2 kg in 2-5 months; all the patients tolerated enteral feeding and were discharged in the early period. There were neither procedure related complications such as perforation, bleeding nor sedation related complications. Procedure took no more than 30 min as a whole. There was no need for surgical intervention. However in one patient re-intervention was required due to accidental removal of the catheter. Conclusions: In case of feeding difficulties following the gastrostomy; instead of an invasive surgical intervention; physicians should consider jejunal feeding that is advanced through the gastrostomy, which does not require any anaesthesia.

  3. Automatic Lumbar Vertebrae Segmentation in Fluoroscopic Images Via Optimised Concurrent Hough Transform

    National Research Council Canada - National Science Library

    Zheng, Yalin

    2001-01-01

    .... Digital videofluoroscopy (DVF) was widely used to obtain images for motion studies. This can provide motion sequences of the lumbar spine, but the images obtained often suffer due to noise, exacerbated by the very low radiation dosage...

  4. Radiation dose reduction in fluoroscopic procedures: left varicocele embolization as a model

    Energy Technology Data Exchange (ETDEWEB)

    Verstandig, Anthony G.; Shraibman, Vladimir [Shaare Zedek Medical Center, Department of Radiology, Interventional Radiology Unit, POB 3235, Jerusalem (Israel); Shamieh, Bashar [St. Joseph Hospital, Department of Radiology, Jerusalem (Israel); Raveh, David [Shaare Zedek Medical Center, Infectious Diseases Unit, POB 3235, Jerusalem (Israel)

    2015-06-01

    To investigate the effect of a radiation reduction program on total dose, fluoroscopy dose per second corrected for body habitus and degree of collimation in left varicocele embolizations (LVE). A radiation reduction program for LVE was implemented, consisting of a technique minimizing fluoroscopy time, using low-dose presets, virtual collimation, and virtual patient positioning. Height, weight, fluoroscopy time, kerma area product (KAP) and reference air kerma (Ka,r) were recorded for 100 consecutive cases satisfying the inclusion criteria. For each patient, a device specific dose correction factor, determined using a phantom, was used to standardize the KAP to that of the cylindrical diameter of the standard man and a collimation index was derived from the KAP and Ka,r. Median fluoroscopy time was 3 minutes (mean 4.5, range 1-23.8). Median KAP was 0.54 Gy/cm{sup 2} (mean 0.82, range 0.12-6.52). There was a significant decrease in KAP/second corrected for cylindrical diameter (p < 0.001) and the collimation index (p < 0.001) over time. This study shows that a dedicated dose reduction program can achieve very low total radiation dose rates for LVE. The significant decrease in collimation index and standardized KAP per second during this study suggest a learning curve for collimation. (orig.)

  5. Fluoroscopic inspection in the non-destructive testing of material today-and tomorrow

    International Nuclear Information System (INIS)

    Bohnsack, G.

    1985-01-01

    A lot of articles in NDT-magazines and reports at NDT-meetings deal with the problems of fluoroscopy, i.e. real time imaging. All of them give theoretical information of conversion factors, line pair sensitivity, input/output, but very few of them give practical hints regarding application for this 'NDT-Toll' which is more and more used in nearly in industrial fields. The imaging systems to be combined with x-ray systems are presented. The aspects of practical use in modern industry are discussed. (Author) [pt

  6. An estimation of doses received by patients in a diagnostic X-ray department

    International Nuclear Information System (INIS)

    Milner, S.C.; Naylor, E.

    1989-01-01

    This article describes a method of estimating the effective dose equivalent received by patients undergoing (non-fluoroscopic) diagnostic x-ray examinations. This allows those clinically or physically directing exposures to comply with the requirement, item 3, in the core knowledge contained in the schedule of the health and safety document number 778. The method described can be carried out without the use of expensive equipment or time consuming procedures and is based on the data contained in the publication NRPB R200. (author)

  7. Portable X-Ray Device

    Science.gov (United States)

    1983-01-01

    Portable x-ray instrument developed by NASA now being produced commercially as an industrial tool may soon find further utility as a medical system. The instrument is Lixiscope - Low Intensity X-Ray Imaging Scope -- a self-contained, battery-powered fluoroscope that produces an instant image through use of a small amount of radioactive isotope. Originally developed by Goddard Space Flight Center, Lixiscope is now being produced by Lixi, Inc. which has an exclusive NASA license for one version of the device.

  8. Effect of Intraoperative Three-Dimensional Imaging During the Reduction and Fixation of Displaced Calcaneal Fractures on Articular Congruence and Implant Fixation

    DEFF Research Database (Denmark)

    Eckardt, Henrik; Lind, Marianne

    2015-01-01

    BACKGROUND: Operative treatment of displaced calcaneal fractures should restore joint congruence, but conventional fluoroscopy is unable to fully visualize the subtalar joint. We questioned whether intraoperative 3-dimensional (3D) imaging would aid in the reduction of calcaneal fractures......, resulting in improved articular congruence and implant positioning. METHOD: Sixty-two displaced calcaneal fractures were operated on using standard fluoroscopic views. When the surgeon had achieved a satisfactory reduction, an intraoperative 3D scan was conducted, malreductions or implant imperfections were...

  9. A Zn-porphyrin complex contributes to bright red color in Parma ham

    OpenAIRE

    Wakamatsu, J.; Nishimura, T.; Hattori, A.

    2004-01-01

    The Italian traditional dry-cured ham (Parma ham) shows a stable bright red color that is achieved without the use of nitrite and/or nitrate. In this study we examined the pigment spectroscopically, fluoroscopically and by using HPLC and ESI-HR-MASS analysis. Porphyrin derivative other than acid hematin were contained in the HCl-containing acetone extract from Parma ham. A strong fluorescence peak at 588 nm and a weak fluorescence peak at 641 nm were observed. By HPLC analysis the acetone ext...

  10. A study on the radiation effect on microvasculature of N-methyl-N-Nitrosourea-induced mammary carcinoma in rats

    International Nuclear Information System (INIS)

    Bae, Sang Hoon; Koh, Kyoung Hwan; Im, Chung Kie; Ha, Sung Hwan; Han, Man Chung

    1985-01-01

    Mammary carcinoma was induced in rats by intravenous injection of N-methyl-N-Nitrosourea. Microangiography was performed to evaluate the microvascular alterations in mammary carcinoma after irradiation. The tumors were given a single dose of 1,400 rads using Co-60 teletherapy unit with field size of 4 x 4 cm at 40 cm SSD. The dose rate was 147.5 rads per minute. Microangiography was performed prior to irradiation and at one, two, and four weeks following irradiation. The results are as follows: 1. Before irradiation, mammary carcinoma in rats tended to form lobules and the basic vasculature consisted of peripheral vascular pattern with central penetrating vessels. The peripheral vascular pattern was always richer than that of the center. Irregular and tortuous vessels stretched from the periphery into the center of lobule. 2. One week following irradiation, an increase in the number of smaller, tortuous vessels and decreased intervascular distance were observed in the central portion of each lobule. This finding seems to be due to an improved filling of some previously existing but unfilled vessels. This may lead to improved metabolic changes and reoxygenation. 3. Later changes of microvasculature after irradiation are tortuosity, irregularity, narrowing, abrupt tapering, fragmentation, and extravasation. These findings progressed after a lapse of time. 4. The results can be considered as the microangiographic demonstration of the fact that reoxygenation after irradiation is mainly due to dilatation of the collapsed tumor vessels

  11. Røntgenstereometrisk analyse efter total knaealloplastik

    DEFF Research Database (Denmark)

    Therbo, Matthias; Lund, Bjarne

    2009-01-01

    In 1974 Selvik introduced marker-based roentgenographic stereogrammetric analysis (RSA), a highly accurate technique for measuring three-dimensional migration of orthopaedic implants. Novel, promising, user-friendly, fast and in some cases noninvasive RSA techniques (model-based RSA, image......-based RSA and fluoroscopic RSA) have been developed, and some have recently been validated. However, the most reliable RSA technique so far is marker-based RSA. A standardization protocol for RSA studies is required. In the future, implant-testing using RSA should be used routinely in selected Danish...

  12. The clinical practice of inserting two stents in esophagus and trachea

    International Nuclear Information System (INIS)

    Han Xinwei; Wu Gang; Gao Xuemei; Ma Nan; Wang Yanli; Li Yongdong

    2005-01-01

    Objective: To study the value of clinical practice of inserting two stents in esophagus and trachea. Methods: Four esophagorespiratory fistulas with severe tracheal stenosis and 7 esophageal stenosises with severe tracheal stenosis, were taken stent placement under fluoroscopic guidance. Results: All cases had their stents placed successfully, with normal diet intake without difficulty together with immediate disappearance of dysprea. Conclusions: It is safe, effective for patients with esophageal cancerous stenosis (or fistula) and tracheal stenosis to be treated by two stents insertion method. (authors)

  13. Percutaneous Mesocaval Shunt Creation in a Patient with Chronic Portal and Superior Mesenteric Vein Thrombosis

    International Nuclear Information System (INIS)

    Bercu, Zachary L.; Sheth, Sachin B.; Noor, Amir; Lookstein, Robert A.; Fischman, Aaron M.; Nowakowski, F. Scott; Kim, Edward; Patel, Rahul S.

    2015-01-01

    The creation of a transjugular intrahepatic portosystemic shunt (TIPS) is a critical procedure for the treatment of recurrent variceal bleeding and refractory ascites in the setting of portal hypertension. Chronic portal vein thrombosis remains a relative contraindication to conventional TIPS and options are limited in this scenario. Presented is a novel technique for management of refractory ascites in a patient with hepatitis C cirrhosis and chronic portal and superior mesenteric vein thrombosis secondary to schistosomiasis and lupus anticoagulant utilizing fluoroscopically guided percutaneous mesocaval shunt creation

  14. Introscope

    International Nuclear Information System (INIS)

    1976-01-01

    An introscope is an array of optical equipments for both industrial and biomedical radiography. A complicated configuration is described of fluoroscopic converters, transforming the penetrating radiation into a flux of visible light, reflecting mirrors, image converters and multipliers, a television circuit (camera, transmission circuit, monitor) alongside a cinematographic recorder. The materials and composition of the various screens, cathodes and substrates are given. The purpose of this equipment is to simultaneously obtain a shadow picture of the interior of the object and its outer structure

  15. Percutaneous Mesocaval Shunt Creation in a Patient with Chronic Portal and Superior Mesenteric Vein Thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Bercu, Zachary L., E-mail: zachary.bercu@mountsinai.org; Sheth, Sachin B., E-mail: sachinsheth@gmail.com [Icahn School of Medicine at Mount Sinai, Division of Interventional Radiology (United States); Noor, Amir, E-mail: amir.noor@gmail.com [The George Washington University School of Medicine and Health Sciences (United States); Lookstein, Robert A., E-mail: robert.lookstein@mountsinai.org; Fischman, Aaron M., E-mail: aaron.fischman@mountsinai.org; Nowakowski, F. Scott, E-mail: scott.nowakowski@mountsinai.org; Kim, Edward, E-mail: edward.kim@mountsinai.org; Patel, Rahul S., E-mail: rahul.patel@mountsinai.org [Icahn School of Medicine at Mount Sinai, Division of Interventional Radiology (United States)

    2015-10-15

    The creation of a transjugular intrahepatic portosystemic shunt (TIPS) is a critical procedure for the treatment of recurrent variceal bleeding and refractory ascites in the setting of portal hypertension. Chronic portal vein thrombosis remains a relative contraindication to conventional TIPS and options are limited in this scenario. Presented is a novel technique for management of refractory ascites in a patient with hepatitis C cirrhosis and chronic portal and superior mesenteric vein thrombosis secondary to schistosomiasis and lupus anticoagulant utilizing fluoroscopically guided percutaneous mesocaval shunt creation.

  16. Spinal Cord Glioblastoma Induced by Radiation Therapy of Nasopharyngeal Rhabdomyosarcoma with MRI Findings: Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Se Jin; Kim, In One [Dept. of Radiology, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2012-09-15

    Radiation-induced spinal cord gliomas are extremely rare. Since the first case was reported in 1980, only six additional cases have been reported.; The radiation-induced gliomas were related to the treatment of Hodgkin's lymphoma, thyroid cancer, and medullomyoblastoma, and to multiple chest fluoroscopic examinations in pulmonary tuberculosis patient. We report a case of radiation-induced spinal cord glioblastoma developed in a 17-year-old girl after a 13-year latency period following radiotherapy for nasopharyngeal rhabdomyosarcoma. MRI findings of our case are described.

  17. Ulnar Collateral Ligament Injuries of the Thumb

    Science.gov (United States)

    McKeon, Kathleen E.; Gelberman, Richard H.; Calfee, Ryan P.

    2013-01-01

    Background: The clinical diagnosis of thumb ulnar collateral ligament disruption has been based on joint angulation during valgus stress testing. This report describes a definitive method of distinguishing between complete and partial ulnar collateral ligament injuries by quantifying translation of the proximal phalanx on the metacarpal head during valgus stress testing. Methods: Sixty-two cadaveric thumbs underwent standardized valgus stress testing under fluoroscopy with the ulnar collateral ligament intact, following an isolated release of the proper ulnar collateral ligament, and following a combined release of both the proper and the accessory ulnar collateral ligament (complete ulnar collateral ligament release). Following complete ulnar collateral ligament release, the final thirty-seven thumbs were also analyzed after the application of a valgus force sufficient to cause 45° of valgus angulation at the metacarpophalangeal joint to model more severe soft-tissue injury. Two independent reviewers measured coronal plane joint angulation (in degrees), ulnar joint line gap formation (in millimeters), and radial translation of the proximal phalanx on the metacarpal head (in millimeters) on digital fluoroscopic images that had been randomized. Results: Coronal angulation across the stressed metacarpophalangeal joint progressively increased through the stages of the testing protocol: ulnar collateral ligament intact (average [and standard deviation], 20° ± 8.1°), release of the proper ulnar collateral ligament (average, 23° ± 8.3°), and complete ulnar collateral ligament release (average, 30° ± 8.9°) (p collateral ligament release (5.7 ± 1.5 mm), to that following complete ulnar collateral ligament release (7.2 ± 1.5 mm) (p collateral ligament (1.6 ± 0.8 mm vs. 1.5 ± 0.9 mm in the intact state). There was a significant increase in translation following release of the complete ulnar collateral ligament complex (3.0 ± 0.9 mm; p collateral ligament

  18. Value of Examination Under Fluoroscopy for the Assessment of Sacroiliac Joint Dysfunction.

    Science.gov (United States)

    Eskander, Jonathan P; Ripoll, Juan G; Calixto, Frank; Beakley, Burton D; Baker, Jeffrey T; Healy, Patrick J; Gunduz, O H; Shi, Lizheng; Clodfelter, Jamie A; Liu, Jinan; Kaye, Alan D; Sharma, Sanjay

    2015-01-01

    Pain emanating from the sacroiliac (SI) joint can have variable radiation patterns. Single physical examination tests for SI joint pain are inconsistent with multiple tests increasing both sensitivity and specificity. To evaluate the use of fluoroscopy in the diagnosis of SI joint pain. Prospective double blind comparison study. Pain clinic and radiology setting in urban Veterans Administration (VA) in New Orleans, Louisiana. Twenty-two adult men, patients at a southeastern United States VA interventional pain clinic, presented with unilateral low back pain of more than 2 months' duration. Patients with previous back surgery were excluded from the study. Each patient was given a Gapping test, Patrick (FABERE) test, and Gaenslen test. A second blinded physician placed each patient prone under fluoroscopic guidance, asking each patient to point to the most painful area. Pain was provoked by applying pressure with the heel of the palm in that area to determine the point of maximum tenderness. The area was marked with a radio-opaque object and was placed on the mark with a fluoroscopic imgage. A site within 1 cm of the SI joint was considered as a positive test. This was followed by a diagnostic injection under fluoroscopy with 1 mL 2% lidocaine. A positive result was considered as more than 2 hours of greater than 75% reduction in pain. Then, in 2-3 days this was followed by a therapeutic injection under fluoroscopy with 1 mL 0.5% bupivacaine and 40 mg methylprednisolone. Each patient was reassessed after 6 weeks. The sensitivity and specificity in addition to the positive and negative predictive values were determined for both the conventional examinations, as well as the examination under fluoroscopy. Finally, a receiver operating characteristic (ROC) curve was constructed to evaluate test performance. The sensitivity and specificity of the fluoroscopic examination were 0.82 and 0.80 respectively; Positive predictive value and negative predictive value were 0.93 and

  19. Percutaneous Augmented Peripheral Osteoplasty in Long Bones of Oncologic Patients for Pain Reduction and Prevention of Impeding Pathologic Fracture: The Rebar Concept

    International Nuclear Information System (INIS)

    Kelekis, A.; Filippiadis, D.; Anselmetti, G.; Brountzos, E.; Mavrogenis, A.; Papagelopoulos, P.; Kelekis, N.; Martin, J.-B.

    2016-01-01

    PurposeTo evaluate clinical efficacy/safety of augmented peripheral osteoplasty in oncologic patients with long-term follow-up.Materials and MethodsPercutaneous augmented peripheral osteoplasty was performed in 12 patients suffering from symptomatic lesions of long bones. Under extensive local sterility measures, anesthesiology care, and fluoroscopic guidance, direct access to lesion was obtained and coaxially a metallic mesh consisting of 25–50 medical grade stainless steel micro-needles (22 G, 2–6 cm length) was inserted. PMMA for vertebroplasty was finally injected under fluoroscopic control. CT assessed implant position 24-h post-treatment.ResultsClinical evaluation included immediate and delayed follow-up studies of patient’s general condition, NVS pain score, and neurological status. Imaging assessed implant’s long-term stability. Mean follow-up was 16.17 ± 10.93 months (range 2–36 months). Comparing patients’ scores prior (8.33 ± 1.67 NVS units) and post (1.42 ± 1.62 NVS units) augmented peripheral osteoplasty, there was a mean decrease of 6.92 ± 1.51 NVS units. Overall mobility improved in 12/12 patients. No complication was observed.ConclusionPercutaneous augmented peripheral osteoplasty (rebar concept) for symptomatic malignant lesions in long bones seems to be a possible new technique for bone stabilization. This combination seems to provide necessary stability against shearing forces applied in long bones during weight bearing

  20. Omentopexy improves vascularization and decreases stricture formation of esophageal anastomoses in a dog model.

    Science.gov (United States)

    Hayari, Lili; Hershko, Dan D; Shoshani, Hadas; Maor, Ron; Mordecovich, Daniel; Shoshani, Gideon

    2004-04-01

    Anastomotic strictures are common after primary esophageal anastomosis in pediatric patients. Recent studies provided evidence that omentopexy may improve vascularization of gastroesophageal anastomoses and decrease the rate of stricture-related complications. The effect of omentopexy on primary esophago-esophageal anastomosis, however, is unknown. The aim of the current study was to examine the role of omentopexy on the healing process of primary midesopageal anastomoses. Six dogs were operated on. A 5-cm portion of the midesophagus was resected, and continuity was restored by end-to-end anastomosis. In 3 dogs, an omental pedicle was placed around the anastomotic region. Eating patterns were recorded and functional swallowing was evaluated by fluoroscopic studies. Eight weeks after the operations, the experimental animals were killed and anastomotic lumen diameters and vascularization of the anastomotic sites were evaluated by radiographic studies and histologic examination, respectively. Two dogs in the omentopexy group were able to resume regular feeding, whereas none of the dogs in the control group were able to tolerate solid food intake. Fluoroscopic studies found preserved motility patterns of the esophagus in the omentoesophagopexy group, while prestenotic dilatation and delayed food clearance through the anastomosis were observed in the control group. Histologically, neovascularization was observed at the anastomotic site in the omentoesophagopexy group in contrast to the marked degree of fibrosis displayed in the control group. Omentopexy may improve vascularization and decrease stricture formation after primary esophagoesophageal anastomosis.

  1. A new one-step procedure for pulmonary valve implantation of the melody valve: Simultaneous prestenting and valve implantation.

    Science.gov (United States)

    Boudjemline, Younes

    2018-01-01

    To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.

  2. Variations of Patient Doses in Interventional Examinations at Different Angiographic Units

    International Nuclear Information System (INIS)

    Bor, Dogan; Toklu, Tuerkay; Olgar, Turan; Sancak, Tanzer; Cekirge, Saruhan; Onal, Baran; Bilgic, Sadik

    2006-01-01

    Purpose. We analyzed doses for various angiographic procedures using different X-ray systems in order to assess dose variations. Methods. Dose-area product (DAP), skin doses from thermoluminescent dosimeters and air kerma measurements of 308 patients (239 diagnostic and 69 interventional) were assessed for five different angiographic units. All fluoroscopic and radiographic exposure parameters were recorded online for single and multiprojection studies. Radiation outputs of each X-ray system were also measured for all the modes of exposure using standard protocols for such measurements. Results. In general, the complexity of the angiographic procedure was found to be the most important reason for high radiation doses. Skill of the radiologist, management of the exposure parameters and calibration of the system are the other factors to be considered. Lateral cerebral interventional studies carry the highest risk for deterministic effects on the lens of the eye. Effective doses were calculated from DAP measurements and maximum fatal cancer risk factors were found for carotid studies. Conclusions. Interventional radiologists should measure patient doses for their examinations. If there is a lack of necessary instrumentation for this purpose, then published dose reports should be used in order to predict the dose levels from some of the exposure parameters. Patient dose information should include not only the measured quantity but also the measured radiation output of the X-ray unit and exposure parameters used during radiographic and fluoroscopic exposures

  3. Human Thiel-Embalmed Cadaveric Aortic Model with Perfusion for Endovascular Intervention Training and Medical Device Evaluation.

    Science.gov (United States)

    McLeod, Helen; Cox, Ben F; Robertson, James; Duncan, Robyn; Matthew, Shona; Bhat, Raj; Barclay, Avril; Anwar, J; Wilkinson, Tracey; Melzer, Andreas; Houston, J Graeme

    2017-09-01

    The purpose of this investigation was to evaluate human Thiel-embalmed cadavers with the addition of extracorporeal driven ante-grade pulsatile flow in the aorta as a model for simulation training in interventional techniques and endovascular device testing. Three human cadavers embalmed according to the method of Thiel were selected. Extracorporeal pulsatile ante-grade flow of 2.5 L per min was delivered directly into the aorta of the cadavers via a surgically placed connection. During perfusion, aortic pressure and temperature were recorded and optimized for physiologically similar parameters. Pre- and post-procedure CT imaging was conducted to plan and follow up thoracic and abdominal endovascular aortic repair as it would be in a clinical scenario. Thoracic endovascular aortic repair (TEVAR) and endovascular abdominal repair (EVAR) procedures were conducted in simulation of a clinical case, under fluoroscopic guidance with a multidisciplinary team present. The Thiel cadaveric aortic perfusion model provided pulsatile ante-grade flow, with pressure and temperature, sufficient to conduct a realistic simulation of TEVAR and EVAR procedures. Fluoroscopic imaging provided guidance during the intervention. Pre- and post-procedure CT imaging facilitated planning and follow-up evaluation of the procedure. The human Thiel-embalmed cadavers with the addition of extracorporeal flow within the aorta offer an anatomically appropriate, physiologically similar robust model to simulate aortic endovascular procedures, with potential applications in interventional radiology training and medical device testing as a pre-clinical model.

  4. A new model with an anatomically accurate human renal collecting system for training in fluoroscopy-guided percutaneous nephrolithotomy access.

    Science.gov (United States)

    Turney, Benjamin W

    2014-03-01

    Obtaining renal access is one of the most important and complex steps in learning percutaneous nephrolithotomy (PCNL). Ideally, this skill should be practiced outside the operating room. There is a need for anatomically accurate and cheap models for simulated training. The objective was to develop a cost-effective, anatomically accurate, nonbiologic training model for simulated PCNL access under fluoroscopic guidance. Collecting systems from routine computed tomography urograms were extracted and reformatted using specialized software. These images were printed in a water-soluble plastic on a three-dimensional (3D) printer to create biomodels. These models were embedded in silicone and then the models were dissolved in water to leave a hollow collecting system within a silicone model. These PCNL models were filled with contrast medium and sealed. A layer of dense foam acted as a spacer to replicate the tissues between skin and kidney. 3D printed models of human collecting systems are a useful adjunct in planning PCNL access. The PCNL access training model is relatively low cost and reproduces the anatomy of the renal collecting system faithfully. A range of models reflecting the variety and complexity of human collecting systems can be reproduced. The fluoroscopic triangulation process needed to target the calix of choice can be practiced successfully in this model. This silicone PCNL training model accurately replicates the anatomic architecture and orientation of the human renal collecting system. It provides a safe, clean, and effective model for training in accurate fluoroscopy-guided PCNL access.

  5. The value of flat-detector computed tomography during catheterisation of congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Gloeckler, Martin [University Hospital Erlangen, Department of Pediatric Cardiology, Erlangen (Germany); Friedrich-Alexander University Erlangen-Nuernberg, Department of Pediatric Cardiology, Erlangen (Germany); Koch, Andreas; Greim, Verena; Shabaiek, Amira; Dittrich, Sven [University Hospital Erlangen, Department of Pediatric Cardiology, Erlangen (Germany); Rueffer, Andre; Cesnjevar, Robert [University Hospital Erlangen, Department of Congenital Heart Surgery, Erlangen (Germany); Achenbach, Stephan [University Hospital Erlangen, Department of Cardiology, Erlangen (Germany)

    2011-12-15

    To analyse the diagnostic utility of flat-detector computed tomography imaging (FD-CT) in patients with congenital heart disease, including the value of image fusion to overlay three-dimensional (3D) reconstructions on fluoroscopic images during catheter-based interventions. We retrospectively analysed 62 consecutive paediatric patients in whom FD-CT was used during catheterisation of congenital heart disease. Expert operators rated the clinical value of FD-CT over conventional fluoroscopic imaging. Added radiation exposure and contrast medium volume were evaluated. During a 12-month period, FD-CT was performed in 62 out of 303 cardiac catheterisations. Median patient age was 3.5 years. In 32/62 cases, FD-CT was used for diagnostic purposes, in 30/62 cases it was used in the context of interventions. Diagnostic utility was never rated as ''misleading''. It was classified as ''not useful'' in six cases (9.7%), ''useful'' in 18 cases (29.0%), ''very useful'' in 37 cases (59.7%) and ''essential'' in one case (1.6%). The median added dose-area product was 111.0 {mu}Gym{sup 2}, the required additional quantity of contrast medium was 1.6 ml/kg. FD-CT provides useful diagnostic information in most of the patients investigated for congenital heart disease. The added radiation exposure and contrast medium volume are reasonable. (orig.)

  6. Percutaneous Retrieval of Foreign Bodies Around Vital Vessels Aided with Vascular Intervention: A Technical Note

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Xiu-Jun, E-mail: woothingyang2008@126.com [Shanghai Eighth People’s Hospital, Department of Radiology (China); Xing, Guang-Fu, E-mail: xgf8848@126.com [Shanghai Eighth People’s Hospital, Department of General Surgery (China)

    2015-10-15

    ObjectiveTo describe a new interventional technique to remove foreign bodies (FBs) embedded in soft tissues around vital vessels.MethodsUnder fluoroscopic guidance and using local anesthesia, percutaneous removal of FBs was performed using forceps in nine patients. All patients suffered from a metallic soft tissue FB located in close proximity to important vessels and one also had a small traumatic pseudoaneurysm adjacent to the FB. Prior to removal of the FB, the position of the nearest vessel was identified using a guide wire or catheter placed into the vessel. Balloon catheter was also simultaneously used to temporarily stop the blood flow of the nearest artery during the FB removal in three of the nine patients.ResultsAll of the nine FBs with 0–2 mm interval to the nearest vessel were successfully removed in the nine patients without any serious complications. The removed FBs measured 3–12 mm in length and 1–3 mm in width. The total fluoroscopic time of retrieval of each FB was 5–9 min (mean, 6.4 min). The volume of intraoperative bleeding ranged from 5 to 12 ml (mean, 7.5 ml). The length of hospital stay for each patient ranged from 4 to 8 days (mean, 5.5 days).ConclusionVascular intervention-aided percutaneous FB removal is minimally invasive and an effective method for removal of FBs around vital vessels.

  7. The posterior transtriceps approach for elbow arthrography: a forgotten technique?

    International Nuclear Information System (INIS)

    Lohman, M.; Borrero, C.; Casagranda, B.; Rafiee, B.; Towers, J.

    2009-01-01

    To evaluate the technical feasibility of performing elbow MR arthrography via a posterior approach through the triceps. The images of 19 patients with elbow MR arthrography via a posterior transtriceps approach were retrospectively studied. The injections were performed by four musculoskeletal radiologists, using fluoroscopic guidance and a 22- or 25-gauge needle. The fluoroscopic and subsequent MR images were reviewed by two musculoskeletal radiologists and evaluated for adequacy of joint capsular distention, degree and location of contrast leakage, and presence of gas bubbles. The injection was diagnostic in all 19 patients, with a sufficient amount of contrast agent seen in the elbow joint. No significant contrast leakage occurred in 12 patients who received injections of 8 cc or less of contrast agent, but moderate contrast leakage occurred in 6/7 patients who received injections of greater than 8 cc. Contrast leakage generally occurred within the triceps myotendinous junction. No gas bubbles were identified in the injected joints. Patients often present for MR arthrography of the elbow with medial or lateral elbow pain. Contrast leakage during a radiocapitellar approach may complicate evaluation of the lateral collateral ligament or the common extensor tendon origin. Transtriceps MR arthrography offers an alternative to the more commonly used radiocapitellar approach. With injected volumes not exceeding 8 cc, the risk of significant contrast leakage is small. An advantage of the transtriceps injection is that contrast leakage through the posterior needle tract does not interfere with evaluation of the lateral structures. (orig.)

  8. Uterine artery embolisation for uterine fibroids using a 4F Rosch inferior mesenteric catheter

    International Nuclear Information System (INIS)

    Ho, Simon S.M.; Cowan, Nigel C.

    2005-01-01

    Purpose:To evaluate in a prospective study the use of a 4F Rosch inferior mesenteric (RIM) catheter for uterine artery embolisation (UAE). UAE was performed in 72 women over a 37-month period. A 4F RIM braided J-curve 65-cm catheter was used in combination with an angled hydrophilic 150 cm, 0.035'' flexible tip guide-wire to catheterise the horizontal portion of both uterine arteries (UA) from a right common femoral artery (CFA) approach. Technical success was defined as successful catheterisation and embolisation of both uterine arteries. Fluoroscopic and procedure times were recorded. Mean subject age=43.7 years (range=25-57 years). Technical success was 98.6% (n=71/72). A single approach via the right CFA was used in 88.9% (n=64/72) and a bilateral CFA approach in 11.1% (n=8/72). Bilateral uterine artery catheterisation using a single 4F RIM catheter via the right CFA approach was successful in 79.2% (n=57/72). Microcatheters were used in 2.8% of patients (n=2/72). Mean fluoroscopic time=13.6±5.3 min (mean±SD). Mean procedure time=44.2±16.5 min. High technical success rate for UAE is possible using a single 4F RIM catheter via a unilateral right CFA approach, which obviates the need for Waltman loop formation, reversed curve catheters and complex suture-catheter arrangements. (orig.)

  9. Percutaneous Augmented Peripheral Osteoplasty in Long Bones of Oncologic Patients for Pain Reduction and Prevention of Impeding Pathologic Fracture: The Rebar Concept

    Energy Technology Data Exchange (ETDEWEB)

    Kelekis, A., E-mail: akelekis@med.uoa.gr; Filippiadis, D., E-mail: dfilippiadis@yahoo.gr [University General Hospital “ATTIKON”, 2nd Radiology Department (Greece); Anselmetti, G., E-mail: gc.anselmetti@fastwebnet.it [GVM Care and Research Maria Pia Hospital (Italy); Brountzos, E., E-mail: ebrountz@med.uoa.gr [University General Hospital “ATTIKON”, 2nd Radiology Department (Greece); Mavrogenis, A., E-mail: afm@otenet.gr; Papagelopoulos, P., E-mail: pjp@hol.gr [University General Hospital “ATTIKON”, A Orthopedic Clinic (Greece); Kelekis, N., E-mail: kelnik@med.uoa.gr [University General Hospital “ATTIKON”, 2nd Radiology Department (Greece); Martin, J.-B., E-mail: jbmartin@cird.ch [Centre Imaginerie Rive Droite & Gauche (Switzerland)

    2016-01-15

    PurposeTo evaluate clinical efficacy/safety of augmented peripheral osteoplasty in oncologic patients with long-term follow-up.Materials and MethodsPercutaneous augmented peripheral osteoplasty was performed in 12 patients suffering from symptomatic lesions of long bones. Under extensive local sterility measures, anesthesiology care, and fluoroscopic guidance, direct access to lesion was obtained and coaxially a metallic mesh consisting of 25–50 medical grade stainless steel micro-needles (22 G, 2–6 cm length) was inserted. PMMA for vertebroplasty was finally injected under fluoroscopic control. CT assessed implant position 24-h post-treatment.ResultsClinical evaluation included immediate and delayed follow-up studies of patient’s general condition, NVS pain score, and neurological status. Imaging assessed implant’s long-term stability. Mean follow-up was 16.17 ± 10.93 months (range 2–36 months). Comparing patients’ scores prior (8.33 ± 1.67 NVS units) and post (1.42 ± 1.62 NVS units) augmented peripheral osteoplasty, there was a mean decrease of 6.92 ± 1.51 NVS units. Overall mobility improved in 12/12 patients. No complication was observed.ConclusionPercutaneous augmented peripheral osteoplasty (rebar concept) for symptomatic malignant lesions in long bones seems to be a possible new technique for bone stabilization. This combination seems to provide necessary stability against shearing forces applied in long bones during weight bearing.

  10. Efficacy of the RADPAD protective drape during real world complex percutaneous coronary intervention procedures.

    Science.gov (United States)

    Murphy, John C; Darragh, Karen; Walsh, Simon J; Hanratty, Colm G

    2011-11-15

    The RADPAD is a lead-free surgical drape containing bismuth and barium that has been demonstrated to reduce scatter radiation exposure to primary operators during fluoroscopic procedures. It is not known to what degree the RADPAD reduces radiation exposure in operators who perform highly complex percutaneous coronary intervention (PCI) requiring prolonged fluoroscopic screening times. Sixty consecutive patients due to undergo elective complex PCI involving rotational atherectomy, multivessel PCI, or chronic total occlusions were randomized in a 1:1 pattern to have their procedures performed with and without the RADPAD drape in situ. Dosimetry was performed on the left arm of the primary operator. There were 40 cases of chronic total occlusion, including 28 with contralateral injections; 15 cases involving rotational atherectomy; and 5 cases of multivessel PCI. There was no significant difference in screening times or dose-area products between the 2 patient groups. Primary operator radiation dose relative to screening time (RADPAD: slope = 1.44, R² = 0.25; no RADPAD: slope = 4.60, R² = 0.26; analysis of covariance F = 4.81, p = 0.032) and dose-area product (RADPAD: slope = 0.003, R² = 0.26; no RADPAD: slope = 0.011, R² = 0.52; analysis of covariance F = 12.54, p = 0.008) was significantly smaller in the RADPAD cohort compared to the no-RADPAD group. In conclusion, the RADPAD significantly reduces radiation exposure to primary operators during prolonged, complex PCI cases. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Significance of preoperative planning software for puncture and channel establishment in percutaneous endoscopic lumbar DISCECTOMY: A study of 40 cases.

    Science.gov (United States)

    Hu, Zhouyang; Li, Xinhua; Cui, Jian; He, Xiaobo; Li, Cong; Han, Yingchao; Pan, Jie; Yang, Mingjie; Tan, Jun; Li, Lijun

    2017-05-01

    Preoperative planning software has been widely used in many other minimally invasive surgeries, but there is a lack of information describing the clinical benefits of existing software applied in percutaneous endoscopic lumbar discectomy (PELD). This study aimed to compare the clinical efficacy of preoperative planning software in puncture and channel establishment of PELD with routine methods in treating lumbar disc herniation (LDH). From June 2016 to October 2016, 40 patients who had single L4/5 or L5/S1 disc herniation were divided into two groups. Group A adopted planning software for preoperative puncture simulation while Group B took routine cases discussion for making puncture plans. The channel establishment time, operative time, fluoroscopic times and complications were compared between the two groups. The surgical efficacy was evaluated according to the Visual Analogue Scale (VAS), Oswestry Disability Index (ODI) and modified Macnab's criteria. The mean channel establishment time was 25.1 ± 4.2 min and 34.6 ± 5.4 min in Group A and B, respectively (P  0.05). The findings of modified Macnab's criteria at each follow-up also showed no significant differences (P > 0.05). The application of preoperative planning software in puncture and cannula insertion planning in PELD was easy and reliable, and could reduce the channel establishment time, operative time and fluoroscopic times of PELD significantly. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  12. Fixed-flexion radiography of the knee provides reproducible joint space width measurements in osteoarthritis

    International Nuclear Information System (INIS)

    Kothari, Manish; Sieffert, Martine; Block, Jon E.; Peterfy, Charles G.; Guermazi, Ali; Ingersleben, Gabriele von; Miaux, Yves; Stevens, Randall

    2004-01-01

    The validity of a non-fluoroscopic fixed-flexion radiographic acquisition and analysis protocol for measurement of joint space width (JSW) in knee osteoarthritis is determined. A cross-sectional study of 165 patients with documented knee osteoarthritis participating in a multicenter, prospective study of chondroprotective agents was performed. All patients had posteroanterior, weight-bearing, fixed-flexion radiography with 10 caudal beam angulation. A specially designed frame (SynaFlexer) was used to standardize the positioning. Minimum medial and lateral JSW were measured manually and twice by an automated analysis system to determine inter-technique and intra-reader concordance and reliability. A random subsample of 30 patients had repeat knee radiographs 2 weeks apart to estimate short-term reproducibility using automated analysis. Concordance between manual and automated medial JSW measurements was high (ICC=0.90); lateral compartment measurements showed somewhat less concordance (ICC=0.72). There was excellent concordance between repeated automated JSW measurements performed 6 months apart for the medial (ICC=0.94) and lateral (ICC=0.86) compartments. Short-term reproducibility for the subsample of 30 cases with repeat acquisitions demonstrated an average SD of 0.14 mm for medial JSW (CV=4.3%) and 0.23 mm for lateral JSW (CV=4.0%). Fixed-flexion radiography of the knee using a positioning device provides consistent, reliable and reproducible measurement of minimum JSW in knee osteoarthritis without the need for concurrent fluoroscopic guidance. (orig.)

  13. Which is best way of performing a Micturating Cystourethrogram in children?

    International Nuclear Information System (INIS)

    Al-Imam, Ola Ali; Al-Nsour, Nareeman Moh'd; Al-Khulaifat, S.

    2008-01-01

    The Micturating Cystourethrogram (MC) is a tough and stressful examination for patients and their parents as well as the radiologists and pediatric radiology nurses. Even though, it is one of the most commonly used fluoroscopic procedures in pediatric radiology practice, there is no definite agreement as to the best way to perform it, considering that this examination results in the children receiving a high dose of radiation to the gonadal region. This review was undertaken to determine the best way to perform the MCU in modern pediatric radiology practice. (author)

  14. Digital cardiovascular imaging

    International Nuclear Information System (INIS)

    Myerowitz, P.D.; Mistretta, C.A.; Shaw, C.-G.; Van Lysel, M.S.; Swanson, D.K.; Lasser, T.A.; Dhanani, S.P.; Zarnstorff, W.C.; Vander Ark, C.R.; Dobbins, J.T.; Peppler, W.W.; Crummy, A.B.

    1982-01-01

    The authors have previously reported on real time digital fluoroscopic subtraction techniques developed in the laboratory during the past 10 years. This paper outlines basic apparatus configuration and imaging modes used for preliminary studies involving visualization of the canine and human heart. All of the techniques involve the use of real time digital subtraction processing of data from an image intensified television fluoroscopy system. Based on the configuration of the digital processing equipment a number of different imaging modalities are possible. A brief description of the apparatus and these imaging modes is given. (Auth.)

  15. Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy

    International Nuclear Information System (INIS)

    Lin, Pei-Jan Paul

    2009-01-01

    New generation of fluoroscopic imaging systems is equipped with spectral shaping filters complemented with sophisticated automatic dose rate and image quality control logic called ''fluoroscopy curve'' or ''trajectory''. Such fluoroscopy curves were implemented first on cardiovascular angiographic imaging systems and are now available on conventional fluoroscopy equipment. This study aims to investigate the control logic operations under the fluoroscopy mode and acquisition mode (equivalent to the legacy spot filming) of a conventional fluoroscopy system typically installed for upper-lower gastrointestinal examinations, interventional endoscopy laboratories, gastrointestinal laboratory, and pain clinics.

  16. Treatment of a Ruptured Anastomotic Esophageal Stricture Following Bougienage with a Dacron-Covered Nitinol Stent

    International Nuclear Information System (INIS)

    Heindel, Walter; Gossmann, Axel; Fischbach, Roman; Michel, Olaf; Lackner, Klaus

    1996-01-01

    A patient suffering from esophagorespiratory fistula after bougienage of a benign stricture at the site of the anastomosis between a jejunal interposition and the esophagus was referred for interventional treatment. A prototype nitinol stent centrally covered with Dacron was implanted under regional anesthesia and fluoroscopic guidance. The self-expanding prosthesis dilated the stenosis completely and closed the fistula, with consequent improvement in respiratory and nutritional status and thus the general quality of life. The patient was able to eat and drink normally until death 3 months later due to progression of his underlying malignant disease

  17. Injectable iodine-125 labeled tissue marker for radioactive localization of non-palpable breast lesions

    DEFF Research Database (Denmark)

    Schaarup-Jensen, Henrik; Jensen, Andreas Ingemann; Hansen, Anders Elias

    2018-01-01

    to be spatially well-defined and stable over a seven day period with excellent CT contrast (>1500 HU), enabling fluoroscopic visualization of markers during placement. The radioactivity remains strongly associated with the marker during the implantation period, which limits exposure to healthy tissue....... The surgical guidance marker is based on derivatives of the biomaterial sucrose acetate isobutyrate and unlike currently used markers it is injectable in the tissue using thin needles, reducing the discomfort to the patients significantly. The marker confers CT contrast and has radioactive properties, meaning...

  18. What do unsuccessful radiographs contribute to the total radiation dose to a patient

    International Nuclear Information System (INIS)

    Roth, J.; Nemec, H.W.

    1985-01-01

    Prevention of, or reduction of, unnecessary exposure to radiation is one of the prime goals of radiological protection in diagnostic radiology. The paper explains the advantages of a new approach, namely to achieve optimum focussing and adjustment of radiation sources for difficult imaging tasks by way of the fluoroscopic rather than the collimator method. The patient's exposure during this preliminary examination on the average will amount to 25 p.c. of the doses applied by the subsequent radiograph; on the other hand, this approach will reduce the number of unsuccessful pictures. (orig.) [de

  19. Ultrasonographic-guided, percutaneous antegarde pyelography: technique and clinical application in the dog and cat

    International Nuclear Information System (INIS)

    Rivers, B.J.; Walter, P.A.; Polzin, D.J.

    1997-01-01

    Fluoroscopically guided, percutaneous antegrade pyelography in canine patients has been described previously in the veterinary literature. This report describes the technique with ultrasonographic guidance and its clinical application in the diagnosis of four cases (two dogs, two cats) of obstructive uropathy. The technique provided successful diagnosis of ureteral obstruction in all four cases. No complications were observed in three cases. In one feline case, ureteral obstruction with a blood clot occurred following the procedure; however, it could not be ascertained whether this event represented a complication of the technique

  20. Chromosomal aberrations and exposure doses during extracorporeal shock wave lithotripsy for renal ureteral stones

    International Nuclear Information System (INIS)

    Shao Songsheng; Feng Jialin; Weng Zhigen; Jiang Qingqi; Wang Guomin; Zhang Yuanfang; Zhang Renan

    1991-01-01

    The radiation dose and the chromosomal aberrations of peripheral lymphocytes were studied in 20 patients during ESWL. The dose was measured with calibrated thermoluminescent dosimeters. Primary results showed an average skin exposure 4.50 x 10 -3 C/kg per case. The dose level is smilar to that of the patients under-going routine fluoroscopic examination. Therefore, the radiation exposure with patients from the ESWL procedure should be considered acceptable. As chromosome changes, to reduce the radiation dose is important for the radiation cytogentics. The factors influencing exposure levels include stone characteristics and physician experience