WorldWideScience

Sample records for microanalysis electronic resource

  1. Progress in x-ray microanalysis in the analytical electron microscope

    International Nuclear Information System (INIS)

    Williams, D.B.

    1987-01-01

    Analytical electron microscopes (AEM) consisting of x-ray energy dispersive spectrometers (EDS) interfaced to scanning transmission electron microscopes have been available for more than a decade. During that time, progress towards reaching the fundamental limits of the technique has been slow. The progress of x-ray microanalysis in AEM is examined in terms of x-ray detector technology; the EDS/AEM interface; accuracy of microanalysis; and spatial resolution and detectability limits. X-ray microanalysis in the AEM has substantial room for improvement in terms of the interface between the detector and the microscope. Advances in microscope design and software should permit 10nm resolution with detectability limits approaching 0.01wt percent. 16 refs., 2 figs., 1 tab

  2. Developments in quantitative electron probe microanalysis

    International Nuclear Information System (INIS)

    Tixier, R.

    1977-01-01

    A study of the range of validity of the formulae for corrections used with massive specimen analysis is made. The method used is original; we have shown that it was possible to use a property of invariability of corrected intensity ratios for standards. This invariance property provides a test for the self consistency of the theory. The theoretical and experimental conditions required for quantitative electron probe microanalysis of thin transmission electron microscope specimens are examined. The correction formulae for atomic number, absorption and fluorescence effects are calculated. Several examples of experimental results are given, relative to the quantitative analysis of intermetallic precipitates and carbides in steels. Advances in applications of electron probe instruments related to the use of computer and the present development of fully automated instruments are reviewed. The necessary statistics for measurements of X ray count data are studied. Estimation procedure and tests are developed. These methods are used to perform a statistical check of electron probe microanalysis measurements and to reject rogue values. An estimator of the confidence interval of the apparent concentration is derived. Formulae were also obtained to optimize the counting time in order to obtain the best precision in a minimum amount of time [fr

  3. Titanium pigmentation. An electron probe microanalysis study

    International Nuclear Information System (INIS)

    Dupre, A.; Touron, P.; Daste, J.; Lassere, J.; Bonafe, J.L.; Viraben, R.

    1985-01-01

    A patient had an unusual pigmentary disease induced by titanium dioxide. The use of a topical cream containing titanium dioxide caused a xanthomalike appearance on the patient's penis. Electron probe microanalysis was valuable in establishing the cause of this balanitis

  4. Quantitative energy-dispersive electron probe X-ray microanalysis ...

    Indian Academy of Sciences (India)

    Abstract. An energy-dispersive electron probe X-ray microanalysis (ED-EPMA) technique us- ing an energy-dispersive X-ray detector with an ultra-thin window, designated as low-Z particle. EPMA, has been developed. The low-Z particle EPMA allows the quantitative determination of concentrations of low-Z elements such ...

  5. Transmission electron microscopy physics of image formation and microanalysis

    CERN Document Server

    Reimer, Ludwig

    1993-01-01

    "Transmission Electron Microscopy" presents the theory of image and contrastformation, and the analytical modes in transmission electron microscopy Theprinciples of particle and wave optics of electrons are described Electron-specimen interactions are discussed for evaluating the theory of scattering and phase contrast Also analysed are the kinetical and dynamical theories of electron diffraction and their applications for crystal-structure determination and imaging of lattices and their defects X-ray microanalysis and electron energy-loss spectroscopy are treated as analytical methods The third edition includes a brief discussionof Schottky emission guns, some clarification of minor details, and references to the recent literature

  6. A versatile atomic number correction for electron-probe microanalysis

    International Nuclear Information System (INIS)

    Love, G.; Cox, M.G.; Scott, V.D.

    1978-01-01

    A new atomic number correction is proposed for quantitative electron-probe microanalysis. Analytical expressions for the stopping power S and back-scatter R factors are derived which take into account atomic number of the target, incident electron energy and overvoltage; the latter expression is established using Monte Carlo calculations. The correct procedures for evaluating S and R for multi-element specimens are described. The new method, which overcomes some limitations inherent in earlier atomic number corrections, may readily be used where specimens are inclined to the electron beam. (author)

  7. Advanced Microanalysis Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Advanced Microanalysis Facility fully integrates capabilities for chemical and structural analysis of electronic materials and devices for the U.S. Army and DoD....

  8. Standardless quantification by parameter optimization in electron probe microanalysis

    International Nuclear Information System (INIS)

    Limandri, Silvina P.; Bonetto, Rita D.; Josa, Víctor Galván; Carreras, Alejo C.; Trincavelli, Jorge C.

    2012-01-01

    A method for standardless quantification by parameter optimization in electron probe microanalysis is presented. The method consists in minimizing the quadratic differences between an experimental spectrum and an analytical function proposed to describe it, by optimizing the parameters involved in the analytical prediction. This algorithm, implemented in the software POEMA (Parameter Optimization in Electron Probe Microanalysis), allows the determination of the elemental concentrations, along with their uncertainties. The method was tested in a set of 159 elemental constituents corresponding to 36 spectra of standards (mostly minerals) that include trace elements. The results were compared with those obtained with the commercial software GENESIS Spectrum® for standardless quantification. The quantifications performed with the method proposed here are better in the 74% of the cases studied. In addition, the performance of the method proposed is compared with the first principles standardless analysis procedure DTSA for a different data set, which excludes trace elements. The relative deviations with respect to the nominal concentrations are lower than 0.04, 0.08 and 0.35 for the 66% of the cases for POEMA, GENESIS and DTSA, respectively. - Highlights: ► A method for standardless quantification in EPMA is presented. ► It gives better results than the commercial software GENESIS Spectrum. ► It gives better results than the software DTSA. ► It allows the determination of the conductive coating thickness. ► It gives an estimation for the concentration uncertainties.

  9. Optimization of Actinide Quantification by Electron Probe Microanalysis

    International Nuclear Information System (INIS)

    Moy, A.; Merlet, C.; Llovet, X.; Dugne, O.

    2013-06-01

    Conventional quantitative electron probe microanalysis of actinides requires the use of reference standard samples. However, for such elements, standards are generally not available. To overcome this difficulty, standard-less methods of analysis are used, in which the x-ray intensity emitted by the standard is calculated. To be reliable, such calculations require accurate knowledge of physical data such as the x-ray production cross section. However, experimental data of this quantity are not always available for actinide elements. In the present work, experimental L and M x-ray production cross sections were measured for elements uranium and lead. Measurements were performed with two electron microprobes using wavelength-dispersive spectrometers using thin self-supporting targets. Experimental results are compared with calculated cross sections obtained from different analytical formulae, and, whenever possible, with experimental data obtained from the literature. (authors)

  10. Optimization of an analytical electron microscope for x-ray microanalysis: instrumental problems

    International Nuclear Information System (INIS)

    Bentley, J.; Zaluzec, N.J.; Kenik, E.A.; Carpenter, R.W.

    1979-01-01

    The addition of an energy dispersive x-ray spectrometer to a modern transmission or scanning transmission electron microscope can provide a powerful tool in the characterization of the materials. Unfortunately this seemingly simple modification can lead to a host of instrumental problems with respect to the accuracy, validity, and quality of the recorded information. This tutorial reviews the complications which can arise in performing x-ray microanalysis in current analytical electron microscopes. The first topic treated in depth is fluorescence by uncollimated radiation. The source, distinguishing characteristics, effects on quantitative analysis and schemes for elimination or minimization as applicable to TEM/STEMs, D-STEMs and HVEMs are discussed. The local specimen environment is considered in the second major section where again detrimental effects on quantitative analysis and remedial procedures, particularly the use of low-background specimen holers, are highlighted. Finally, the detrimental aspects of specimen contamination, insofar as they affect x-ray microanalysis, are discussed. It is concluded that if the described preventive measures are implemented, reliable quantitative analysis is possible

  11. Standardless quantification by parameter optimization in electron probe microanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Limandri, Silvina P. [Instituto de Fisica Enrique Gaviola (IFEG), CONICET (Argentina); Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Medina Allende s/n, (5016) Cordoba (Argentina); Bonetto, Rita D. [Centro de Investigacion y Desarrollo en Ciencias Aplicadas Dr. Jorge Ronco (CINDECA), CONICET, 47 Street 257, (1900) La Plata (Argentina); Facultad de Ciencias Exactas, Universidad Nacional de La Plata, 1 and 47 Streets (1900) La Plata (Argentina); Josa, Victor Galvan; Carreras, Alejo C. [Instituto de Fisica Enrique Gaviola (IFEG), CONICET (Argentina); Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Medina Allende s/n, (5016) Cordoba (Argentina); Trincavelli, Jorge C., E-mail: trincavelli@famaf.unc.edu.ar [Instituto de Fisica Enrique Gaviola (IFEG), CONICET (Argentina); Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Medina Allende s/n, (5016) Cordoba (Argentina)

    2012-11-15

    A method for standardless quantification by parameter optimization in electron probe microanalysis is presented. The method consists in minimizing the quadratic differences between an experimental spectrum and an analytical function proposed to describe it, by optimizing the parameters involved in the analytical prediction. This algorithm, implemented in the software POEMA (Parameter Optimization in Electron Probe Microanalysis), allows the determination of the elemental concentrations, along with their uncertainties. The method was tested in a set of 159 elemental constituents corresponding to 36 spectra of standards (mostly minerals) that include trace elements. The results were compared with those obtained with the commercial software GENESIS Spectrum Registered-Sign for standardless quantification. The quantifications performed with the method proposed here are better in the 74% of the cases studied. In addition, the performance of the method proposed is compared with the first principles standardless analysis procedure DTSA for a different data set, which excludes trace elements. The relative deviations with respect to the nominal concentrations are lower than 0.04, 0.08 and 0.35 for the 66% of the cases for POEMA, GENESIS and DTSA, respectively. - Highlights: Black-Right-Pointing-Pointer A method for standardless quantification in EPMA is presented. Black-Right-Pointing-Pointer It gives better results than the commercial software GENESIS Spectrum. Black-Right-Pointing-Pointer It gives better results than the software DTSA. Black-Right-Pointing-Pointer It allows the determination of the conductive coating thickness. Black-Right-Pointing-Pointer It gives an estimation for the concentration uncertainties.

  12. Sample Preparation for Electron Probe Microanalysis-Pushing the Limits.

    Science.gov (United States)

    Geller, Joseph D; Engle, Paul D

    2002-01-01

    There are two fundamental considerations in preparing samples for electron probe microanalysis (EPMA). The first one may seem obvious, but we often find it is overlooked. That is, the sample analyzed should be representative of the population from which it comes. The second is a direct result of the assumptions in the calculations used to convert x-ray intensity ratios, between the sample and standard, to concentrations. Samples originate from a wide range of sources. During their journey to being excited under the electron beam for the production of x rays there are many possibilities for sample alteration. Handling can contaminate samples by adding extraneous matter. In preparation, the various abrasives used in sizing the sample by sawing, grinding and polishing can embed themselves. The most accurate composition of a contaminated sample is, at best, not representative of the original sample; it is misleading. Our laboratory performs EPMA analysis on customer submitted samples and prepares over 250 different calibration standards including pure elements, compounds, alloys, glasses and minerals. This large variety of samples does not lend itself to mass production techniques, including automatic polishing. Our manual preparation techniques are designed individually for each sample. The use of automated preparation equipment does not lend itself to this environment, and is not included in this manuscript. The final step in quantitative electron probe microanalysis is the conversion of x-ray intensities ratios, known as the "k-ratios," to composition (in mass fraction or atomic percent) and/or film thickness. Of the many assumptions made in the ZAF (where these letters stand for atomic number, absorption and fluorescence) corrections the localized geometry between the sample and electron beam, or takeoff angle, must be accurately known. Small angular errors can lead to significant errors in the final results. The sample preparation technique then becomes very

  13. Electron energy loss spectroscopy microanalysis and imaging in the transmission electron microscope: example of biological applications

    International Nuclear Information System (INIS)

    Diociaiuti, Marco

    2005-01-01

    This paper reports original results obtained in our laboratory over the past few years in the application of both electron energy loss spectroscopy (EELS) and electron spectroscopy imaging (ESI) to biological samples, performed in two transmission electron microscopes (TEM) equipped with high-resolution electron filters and spectrometers: a Gatan model 607 single magnetic sector double focusing EEL serial spectrometer attached to a Philips 430 TEM and a Zeiss EM902 Energy Filtering TEM. The primary interest was on the possibility offered by the combined application of these spectroscopic techniques with those offered by the TEM. In particular, the electron beam focusing available in a TEM allowed us to perform EELS and ESI on very small sample volumes, where high-resolution imaging and electron diffraction techniques can provide important structural information. I show that ESI was able to improve TEM performance, due to the reduced chromatic aberration and the possibility of avoiding the sample staining procedure. Finally, the analysis of the oscillating extended energy loss fine structure (EXELFS) beyond the ionization edges characterizing the EELS spectra allowed me, in a manner very similar to the extended X-ray absorption fine structure (EXAFS) analysis of the X-ray absorption spectra, to obtain short-range structural information for such light elements of biological interest as O or Fe. The Philips EM430 (250-300 keV) TEM was used to perform EELS microanalysis on Ca, P, O, Fe, Al and Si. The assessment of the detection limits of this method was obtained working with well-characterized samples containing Ca and P, and mimicking the actual cellular matrix. I applied EELS microanalysis to Ca detection in bone tissue during the mineralization process and to P detection in the cellular membrane of erythrocytes treated with an anti-tumoral drug, demonstrating that the cellular membrane is a drug target. I applied EELS microanalysis and selected area electron

  14. Correlated microradiography, X-ray microbeam diffraction and electron probe microanalysis of calcifications in an odontoma

    International Nuclear Information System (INIS)

    Aoba, T.; Yoshioka, C.; Yagi, T.

    1980-01-01

    Using microradiography, X-ray microbeam diffraction and electron probe microanalysis, a correlated morphologic and crystallographic study was performed on dysplastic enamel in a compound odontoma. The tumor was found in the lateral incisor-canine region of the left mandible of a 36-year-old woman. A conspicuous feature was the presence of hypomineralized areas, which were situated in the proximity of enamel surface and distinctly demarcated from the adjacent enamel. X-ray microbeam diffraction and electron microanalysis showed that these lesions have a lower crystallinity and a higher concentration of magnesium as compared with the adjacent enamel. In addition, the present study revealed the presence of two other types of calcifications: 1) calcified structures within the fissure or on the enamel surface, which include lacunae of varying size and which resemble a form of coronal cementum, and 2) spherical calcifications which may be an epithelial product. (author)

  15. Biomedical microanalysis--putting it to work now in diagnostic pathology

    International Nuclear Information System (INIS)

    Abraham, J.L.

    1980-01-01

    Based on a review of seven years' experience with microanalysis in human pathology, the emphasis of this keynote paper is that currently available microanalytic instrumentation and methodology are of great use diagnostically. The appropriate diagnostic questions which must be posed for microanalysis center around those seeking the cause of the disease (etiologic diagnosis). The preventive and forensic aspects of etiologic diagnosis are stressed. Pathologists analyse not only tissues but also material samples. The backscattered electron (BSE) image with compositional contrast has been essential in making efficient diagnostic use of microanalysis in the scanning electron microscope (SEM). From the 454 specimens seen in the four years 1976-1979, examples are presented to illustrate several aspects of microanalysis: e.g., documentation of the identity and source of toxic dust in lungs; identification of particulate materials in liver, kidney, salivary glands, lymph nodes, etc.; problems of contamination of specimens; use of high vs low magnification analysis; relative volume of tissue sampled using thick (5 micrometer) vs thin (100nm) sections; time required for analysis; and use of fresh frozen, cryo-sectioned tissue for analysis of soluble materials. For practical diagnostic microanalysis, SEM with BSE and x-ray microanalysis of 5 micrometer thick tissue sections at present seems to be the most efficient procedure

  16. Clinical applications of scanning electron microscopy and X-ray microanalysis in dermatology

    Energy Technology Data Exchange (ETDEWEB)

    Forslind, B.

    1984-01-01

    Scanning electron microscopy is frequently applied to dermatological problems, as is evident from a review of the recent literature. In this paper, preparation methods and new techniques allowing experimental studies on the integumentary system are emphasized. Quantitative analysis in the electron microscope by use of energy-dispersive X-ray microanalysis (EDX) has become an important accessory technique. EDX can, for instance, be used to study problems involving physiological changes induced in skin by agents causing contact reactions. Recently, it has been shown that treatment with DNCB, chromate and nickel causes changes in elemental distribution in guinea-pig skin. In addition, elemental uptake in the integumentary system and in pathological inclusions in skin can be analyzed.

  17. Clinical applications of scanning electron microscopy and X-ray microanalysis in dermatology

    International Nuclear Information System (INIS)

    Forslind, B.

    1984-01-01

    Scanning electron microscopy is frequently applied to dermatological problems, as is evident from a review of the recent literature. In this paper, preparation methods and new techniques allowing experimental studies on the integumentary system are emphasized. Quantitative analysis in the electron microscope by use of energy-dispersive X-ray microanalysis (EDX) has become an important accessory technique. EDX can, for instance, be used to study problems involving physiological changes induced in skin by agents causing contact reactions. Recently, it has been shown that treatment with DNCB, chromate and nickel causes changes in elemental distribution in guinea-pig skin. In addition, elemental uptake in the integumentary system and in pathological inclusions in skin can be analyzed

  18. APPLICATION OF SCANNING ELECTRON MICROSCOPE EQUIPPED WITH THE MICROANALYSIS SYSTEM FOR INVESTIGATION OF BRASS COVERING

    Directory of Open Access Journals (Sweden)

    T. P. Kurenkova

    2010-01-01

    Full Text Available The possibilities of application of scanning electronic microscope equipped with microanalysis system for investigation of the brass covering quality by slug for production of wire and metal cord particularly of change of copper concentration by covering thickness and slug perimeter, revealing of ?-phase allocation presence and character, determination of defect reasons, are shown.

  19. Monte Carlo simulation of the electron and X-ray depth distribution for quantitative electron probe microanalysis of PWR spent fuels

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyoung Mun; Lee, Hyung Kwon; Son, Young Zoon; Chun, Yong Bum [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    Electron probe microanalysis requires several corrections to quantify an element of a specimen. The X-rays produced by the primary beam are created at some depth in the specimen. This distribution is usually represented as the function {Phi}(pz), and it is possible to calculate the correction factors for atomic number and absorption effects. The electron and X-ray depth distributions for a quantitative electron probe micro analysis were simulated by the CASINO Monte Carlo program to quantify some elements of the PWR spent fuel with 50 GWd/tU of burnup and 2 years of cooling time

  20. Monte Carlo simulation of the electron and X-ray depth distribution for quantitative electron probe microanalysis of PWR spent fuels

    International Nuclear Information System (INIS)

    Kwon, Hyoung Mun; Lee, Hyung Kwon; Son, Young Zoon; Chun, Yong Bum

    2011-01-01

    Electron probe microanalysis requires several corrections to quantify an element of a specimen. The X-rays produced by the primary beam are created at some depth in the specimen. This distribution is usually represented as the function Φ(pz), and it is possible to calculate the correction factors for atomic number and absorption effects. The electron and X-ray depth distributions for a quantitative electron probe micro analysis were simulated by the CASINO Monte Carlo program to quantify some elements of the PWR spent fuel with 50 GWd/tU of burnup and 2 years of cooling time

  1. Assessment of homogeneity of candidate reference material at the nanogram level and investigation on representativeness of single particle analysis using electron probe X ray microanalysis

    International Nuclear Information System (INIS)

    Ro, Chul-Un; Hoornaerta, S.; Griekena, R. van

    2002-01-01

    Particulate samples of a candidate reference material are evaluated on their homogeneity from bottle to bottle using electron probe X ray microanalysis technique. The evaluation on the homogeneity is done by the utilization of the Kolmogorov-Smirnov statistics to the processing of the quantitative electron probe X ray microanalysis data. Due to a limitation, existing even in computer controlled electron probe X ray microanalysis, in terms of analysis time and expenses, the number of particles analyzed is much smaller compared to that in the sample. Therefore, it is investigated whether this technique provides representative analysis results for the characteristics of the sample, even though a very small portion of the sample is really analyzed. Furthermore, the required number of particles for the analysis, to insure a certain level of reproducibility, e.g. 5% relative standard deviation, is determined by the application of the Ingamells sampling theory. (author)

  2. Localization of lead within leaf cells of Rhytidiadelphus squarrosus (Hedw. ) Warnst. by means of transmission electron microscopy and X-ray microanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Ophus, E M; Gullvag, B M

    1974-01-01

    Results of ultrastructural studies and transmission electron microscope microanalysis of leaves of the bryophyte Rhytidiadelphus squarrosus collected from a park in Trondheim are presented. The lead content of these leaves primarily derives from motor traffic exhaust gases. A fine structural examination of the leaf cells revealed that detectable amounts of lead had entered the cytoplasm and could be recognized as electron-dense precipitates localized inside the plasma membrane, within vesicles or vacuoles, chloroplasts, mitochondria, microbodies and plasmodesmata. Control material, fixed only in glutaraledhyde and not post-stained, showed that these precipitates must be due to metallic elements having great electron-scattering properties. TEM-X-ray microanalysis indicated the definite presence of lead and phosphorus within both the nuclear and chloroplast inclusions. The possible presence of some other metals is also discussed.

  3. Accurate Cross Sections for Microanalysis

    OpenAIRE

    Rez, Peter

    2002-01-01

    To calculate the intensity of x-ray emission in electron beam microanalysis requires a knowledge of the energy distribution of the electrons in the solid, the energy variation of the ionization cross section of the relevant subshell, the fraction of ionizations events producing x rays of interest and the absorption coefficient of the x rays on the path to the detector. The theoretical predictions and experimental data available for ionization cross sections are limited mainly to K shells of a...

  4. Minimum detection limit and spatial resolution of thin-sample field-emission electron probe microanalysis

    International Nuclear Information System (INIS)

    Kubo, Yugo; Hamada, Kotaro; Urano, Akira

    2013-01-01

    The minimum detection limit and spatial resolution for a thinned semiconductor sample were determined by electron probe microanalysis (EPMA) using a Schottky field emission (FE) electron gun and wavelength dispersive X-ray spectrometry. Comparison of the FE-EPMA results with those obtained using energy dispersive X-ray spectrometry in conjunction with scanning transmission electron microscopy, confirmed that FE-EPMA is largely superior in terms of detection sensitivity. Thin-sample FE-EPMA is demonstrated as a very effective method for high resolution, high sensitivity analysis in a laboratory environment because a high probe current and high signal-to-noise ratio can be achieved. - Highlights: • Minimum detection limit and spatial resolution determined for FE-EPMA. • Detection sensitivity of FE-EPMA greatly superior to that of STEM-EDX. • Minimum detection limit and spatial resolution controllable by probe current

  5. Standardless quantification methods in electron probe microanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Trincavelli, Jorge, E-mail: trincavelli@famaf.unc.edu.ar [Facultad de Matemática, Astronomía y Física, Universidad Nacional de Córdoba, Ciudad Universitaria, 5000 Córdoba (Argentina); Instituto de Física Enrique Gaviola, Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina, Medina Allende s/n, Ciudad Universitaria, 5000 Córdoba (Argentina); Limandri, Silvina, E-mail: s.limandri@conicet.gov.ar [Facultad de Matemática, Astronomía y Física, Universidad Nacional de Córdoba, Ciudad Universitaria, 5000 Córdoba (Argentina); Instituto de Física Enrique Gaviola, Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina, Medina Allende s/n, Ciudad Universitaria, 5000 Córdoba (Argentina); Bonetto, Rita, E-mail: bonetto@quimica.unlp.edu.ar [Centro de Investigación y Desarrollo en Ciencias Aplicadas Dr. Jorge Ronco, Consejo Nacional de Investigaciones Científicas y Técnicas de la República Argentina, Facultad de Ciencias Exactas, de la Universidad Nacional de La Plata, Calle 47 N° 257, 1900 La Plata (Argentina)

    2014-11-01

    The elemental composition of a solid sample can be determined by electron probe microanalysis with or without the use of standards. The standardless algorithms are quite faster than the methods that require standards; they are useful when a suitable set of standards is not available or for rough samples, and also they help to solve the problem of current variation, for example, in equipments with cold field emission gun. Due to significant advances in the accuracy achieved during the last years, product of the successive efforts made to improve the description of generation, absorption and detection of X-rays, the standardless methods have increasingly become an interesting option for the user. Nevertheless, up to now, algorithms that use standards are still more precise than standardless methods. It is important to remark, that care must be taken with results provided by standardless methods that normalize the calculated concentration values to 100%, unless an estimate of the errors is reported. In this work, a comprehensive discussion of the key features of the main standardless quantification methods, as well as the level of accuracy achieved by them is presented. - Highlights: • Standardless methods are a good alternative when no suitable standards are available. • Their accuracy reaches 10% for 95% of the analyses when traces are excluded. • Some of them are suitable for the analysis of rough samples.

  6. Quantitative electron probe microanalysis of boron in binary borides

    International Nuclear Information System (INIS)

    Bastin, G.F.; Heijligers, H.J.M.

    1986-01-01

    Quantitative electron probe microanalysis has been performed in 27 binary borides in the range of 4-30 keV, both for the metals as well as for Boron. The procedures along which accurate intensity measurements for B-K α must be carried out are discussed in detail. A total of 196 k-ratios with respect to elemental standards for the metal X-ray lines and 180 k-ratios for B-K α relative to elemental Boron have been obtained. These data have been used to arrive at an improved parameterization for the φ(ρz) approach in matrix correction. The resulting new program (BAS861) was compared to 5 other current correction programs. At the same occasion the available set of mass absorption coefficients for Boron was tested on its consistency and better values suggested where necessary. Finally it is shown that the modified version of the Gaussian φ(ρz) approach (BAS861 program) is highly successful in the matrix correction for B-K α : a relative root-mean-square value of 6.30% was obtained. (Auth.)

  7. Demonstration of iron and thorium in autopsy tissues by x-ray microanalysis

    International Nuclear Information System (INIS)

    Landas, S.; Turner, J.W.; Moore, K.C.; Mitros, F.A.

    1984-01-01

    We performed x-ray microanalysis of autopsy specimens using a scanning-transmission electron microscopy mode. Tissues were obtained at necropsy from a patient with history of angiography using thorium dioxide and from a patient with hemochromatosis. X-ray microanalysis confirmed the presence of thorium and iron in their respective tissues. Effects of staining reagents were examined

  8. Monte Carlo Simulation of Quantitative Electron Probe Microanalysis of the PWR Spent Fuel with a Pt Coating

    International Nuclear Information System (INIS)

    Kwon, Hyoung Mun; Lee, Hyung Kwon; Son, Young Zoon; Chun, Yong Bum

    2012-01-01

    The PWR spent fuel sample should be coated with conducting material in order to provide a path for electrons and to prevent charging. Generally, the ZAF method has been used for quantitative electron probe microanalysis of conducting samples. However, the coated samples are not applicable for the ZAF method. Probe current, primary electron energy and x-ray produced by the primary beam are attenuated within the coating films. The electron and X-ray depth distributions for a quantitative electron probe micro analysis were simulated by the CASINO Monte Carlo program [2] to evaluate the x-ray attenuation within the Pt coating films. The target samples are the PWR spent fuels with 50 GWd/tU of burnup , 6 years of cooling time and a Pt coating film (3, 5, 7, 10 and 15 nm thickness)

  9. Monte Carlo Simulation of Quantitative Electron Probe Microanalysis of the PWR Spent Fuel with a Pt Coating

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyoung Mun; Lee, Hyung Kwon; Son, Young Zoon; Chun, Yong Bum [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    The PWR spent fuel sample should be coated with conducting material in order to provide a path for electrons and to prevent charging. Generally, the ZAF method has been used for quantitative electron probe microanalysis of conducting samples. However, the coated samples are not applicable for the ZAF method. Probe current, primary electron energy and x-ray produced by the primary beam are attenuated within the coating films. The electron and X-ray depth distributions for a quantitative electron probe micro analysis were simulated by the CASINO Monte Carlo program [2] to evaluate the x-ray attenuation within the Pt coating films. The target samples are the PWR spent fuels with 50 GWd/tU of burnup , 6 years of cooling time and a Pt coating film (3, 5, 7, 10 and 15 nm thickness)

  10. A study of back-trap mottle in coated papers using electron probe microanalysis

    International Nuclear Information System (INIS)

    Eby, T.; Whalen-Shaw, M.

    1991-01-01

    In this paper methodology is been developed for analyzing both the surface and cross-sectional distributions for coating components using electron probe microanalysis and image analysis technology. Actual light and dark areas of print mottle are physically separated and analyzed to provide an unequivocal relationship between the distribution of coating components and the physical structure of the coating in areas of print mottle. Areas of low ink density were found to have higher surface latex concentration, greater mean coating thickness, and greater mean rawstock roughness. Furthermore, the difference in surface concentration of CaCO 3 within areas of, low and high ink density was established as a new and additional probable cause of back-trap mottle

  11. The impact of irradiation induced specimen charging on microanalysis in a scanning electron microscope

    International Nuclear Information System (INIS)

    Stevens-Kalceff, M.A.

    2003-01-01

    Full text: It is necessary to assess and characterize the perturbing influences of experimental probes on the specimens under investigation. The significant influence of electron beam irradiation on poorly conducting materials has been assessed by a combination of specialized analytical scanning electron and scanning probe microscopy techniques including Cathodoluminescence Microanalysis and Kelvin Probe Microscopy. These techniques enable the defect structure and the residual charging of materials to be characterized at high spatial resolution. Cathodoluminescence is the non-incandescent emission of light resulting from the electron irradiation. CL microscopy and spectroscopy in a Scanning Electron Microscope (SEM) enables high spatial resolution and high sensitivity detection of defects in poorly conducting materials. Local variations in the distribution of defects can be non-destructively characterized with high spatial (lateral and depth) resolution by adjusting electron beam parameters to select the specimen micro-volume of interest. Kelvin Probe Microscopy (KPM) is a Scanning Probe Microscopy technique in which long-range Coulomb forces between a conductive atomic force probe and the specimen enable the surface potential to be characterized with high spatial resolution. A combination of Kelvin Probe Microscopy (KPM) and Cathodoluminescence (CL) microanalysis has been used to characterize ultra pure silicon dioxide exposed to electron irradiation in a Scanning Electron Microscope. Silicon dioxide is an excellent model specimen with which to investigate charging induced effects. It is a very poor electrical conductor, homogeneous and electron irradiation produces easily identifiable surface modification which enables irradiated regions to be easily and unambiguously located. A conductive grounded coating is typically applied to poorly conducting specimens prior to investigation in an SEM to prevent deflection of the electron beam and surface charging, however

  12. Electron probe microanalysis for clinical investigations: Microdrop and soft tissue analysis

    International Nuclear Information System (INIS)

    Ingram, M.J.; Ingram, F.D.

    1984-01-01

    The most important advantage offered by electron probe microanalysis (EPA) for clinical investigations is the ability to analyze smaller volumes of tissue than is possible with conventional techniques. The sample can be a biological soft tissue specimen, which involves subcellular localization, or a picoliter fluid droplet. In either case, the analysis can be nondestructive and permit multiple analyses for a number of elements in a given sample. The most highly developed electron microprobe analytical technique is fluid drop analysis, popularly referred to as microdrop analysis. This method provides the investigator with an analytic capability that has an accuracy of measurement often 1% or better on 20 to 30 picoliter fluid droplets. Electron microprobe techniques have been used for studies of animal hard tissue and for studies that involve insoluble inclusions. However, the development of techniques for studies of labile constituents in animal soft tissue has been much slower. It has been necessary not only to develop appropriate methods of tissue preparation, but also to establish sound techniques for tissue collection. Although there are adequate methods for collection of most types of tissue from laboratory animals, many of these methods are not suitable for human subjects. In order to provide the reader with a better understanding of the capabilities and potential for the application of electron microprobe methodology to problems in clinical medicine, the authors discuss some of their experiences with liquid droplet analysis and quantitative electrolyte distribution measurements in animal soft tissue

  13. Energy-dispersive X-ray microanalysis of elements' content and ...

    African Journals Online (AJOL)

    This study was designed to investigate elements' content and anti-microbial effects of two Malaysian plants, Pereskia bleo and Goniothalamus umbrosus. Elements' analysis was carried out using Energy Dispersive X-ray Microanalysis combined with Variable Pressure Scanning Electron Microscope (EDX, VPSEM).

  14. Standard-free electron-probe microanalysis of thin films of HTSC-oxide and semiconductors (h<1μm)

    International Nuclear Information System (INIS)

    Kvardakov, A.M.; Mikhajlova, A.Ya.; San'gin, V.P.; Lazarev, V.B.

    1993-01-01

    A simplified variant of the standard-free electron-probe microanalysis is elaborated to carry out rapid analysis of chemical composition of >1μm thickness thin films of high-temperature superconductor oxides and semiconductors on alien substrates. The suggested technique has increased the efficiency of search for optimal conditions of preparation YBa 2 Cu 3 O x thin films existing in magnetron and InSb ion-beam techniques of spraying on SrTiO 3 and α-Al 2 O 3 monocrystal base substrates

  15. X-ray microanalysis of freeze-dried and frozen-hydrated cryosections

    International Nuclear Information System (INIS)

    Zierold, K.

    1988-01-01

    The elemental composition and the ultrastructure of biological cells were studied by scanning transmission electron microscopy (STEM) combined with energy dispersive X-ray microanalysis. The preparation technique involves cryofixation, cryoultramicrotomy, cryotransfer, and freeze-drying of samples. Freeze-dried cryosections 100-nm thick appeared to be appropriate for measuring the distribution of diffusible elements and water in different compartments of the cells. The lateral analytical resolution was less than 50 nm, depending on ice crystal damage and section thickness. The detection limit was in the range of 10 mmol/kg dry weight for all elements with an atomic number higher than 12; for sodium and magnesium the detection limits were about 30 and 20 mmol/kg dry weight, respectively. The darkfield intensity in STEM is linearly related to the mass thickness. Thus, it becomes possible to measure the water content in intracellular compartments by using the darkfield signal of the dry mass remaining after freeze-drying. By combining the X-ray microanalytical data expressed as dry weight concentrations with the measurements of the water content, physiologically more meaningful wet weight concentrations of elements were determined. In comparison to freeze-dried cryosections frozen-hydrated sections showed poor contrast and were very sensitive against radiation damage, resulting in mass loss. The high electron exposure required for recording X-ray spectra made reproducible microanalysis of ultrathin (about 100-nm thick) frozen-hydrated sections impossible. The mass loss could be reduced by carbon coating; however, the improvement achieved thus far is still insufficient for applications in X-ray microanalysis. Therefore, at present only bulk specimens or at least 1-micron thick sections can be used for X-ray microanalysis of frozen-hydrated biological samples

  16. Electron probe microanalysis of a METAPHIX UPuZr metallic alloy fuel irradiated to 7.0 at.% burn-up

    Energy Technology Data Exchange (ETDEWEB)

    Brémier, S., E-mail: stephan.bremier@ec.europa.eu [European Commission, Joint Research Centre, Institute for Transuranium Elements, P.O. Box 2340, D-76125 Karlsruhe (Germany); Inagaki, K. [Central Research Institute of Electric Power Industry, Nuclear Technology Research Laboratory, 2-11-1 Iwado-kita, Komae-shi, Tokyo 201-8511 (Japan); Capriotti, L.; Poeml, P. [European Commission, Joint Research Centre, Institute for Transuranium Elements, P.O. Box 2340, D-76125 Karlsruhe (Germany); Ogata, T.; Ohta, H. [Central Research Institute of Electric Power Industry, Nuclear Technology Research Laboratory, 2-11-1 Iwado-kita, Komae-shi, Tokyo 201-8511 (Japan); Rondinella, V.V. [European Commission, Joint Research Centre, Institute for Transuranium Elements, P.O. Box 2340, D-76125 Karlsruhe (Germany)

    2016-11-15

    The METAPHIX project is a collaboration between CRIEPI and JRC-ITU investigating safety and performance of a closed fuel cycle option based on fast reactor metal alloy fuels containing Minor Actinides (MA). The aim of the project is to investigate the behaviour of this type of fuel and demonstrate the transmutation of MA under irradiation. A UPuZr metallic fuel sample irradiated to a burn-up of 7 at.% was examined by electron probe microanalysis. The fuel sample was extensively characterised qualitatively and quantitatively using elemental X-ray imaging and point analysis techniques. The analyses reveal a significant redistribution of the fuel components along the fuel radius highlighting a nearly complete depletion of Zr in the central part of the fuel. Numerous rare earth and fission products secondary phases are present in various compositions. Fuel cladding chemical interaction was observed with creation of a number of intermediary layers affecting a cladding depth of 15–20 μm and migration of cladding elements to the fuel. - Highlights: • Electron Probe MicroAnalysis of a UPuZr metallic fuel alloy irradiated to 7.0 at.% burn-up. • Significant redistribution of the fuel components along the fuel radius, nearly complete depletion of Zr in the central part of the fuel. • Interactions between the fuel and the cladding with occurrence of a number of intermediary layers and migration of cladding elements to the fuel. • Safe irradiation behaviour of the base alloy fuel.

  17. Focussed ion beam thin sample microanalysis using a field emission gun electron probe microanalyser

    Science.gov (United States)

    Kubo, Y.

    2018-01-01

    Field emission gun electron probe microanalysis (FEG-EPMA) in conjunction with wavelength-dispersive X-ray spectrometry using a low acceleration voltage (V acc) allows elemental analysis with sub-micrometre lateral spatial resolution (SR). However, this degree of SR does not necessarily meet the requirements associated with increasingly miniaturised devices. Another challenge related to performing FEG-EPMA with a low V acc is that the accuracy of quantitative analyses is adversely affected, primarily because low energy X-ray lines such as the L- and M-lines must be employed and due to the potential of line interference. One promising means of obtaining high SR with FEG-EPMA is to use thin samples together with high V acc values. This mini-review covers the basic principles of thin-sample FEG-EPMA and describes an application of this technique to the analysis of optical fibres. Outstanding issues related to this technique that must be addressed are also discussed, which include the potential for electron beam damage during analysis of insulating materials and the development of methods to use thin samples for quantitative analysis.

  18. Detection of beryllium in oxides and silicates by electron-probe microanalysis

    Directory of Open Access Journals (Sweden)

    V. V. Khiller

    2017-12-01

    Full Text Available The author developed the technique of electron-probe microanalysis for quantitative determination of beryllium content, providing the example of studying natural minerals (aluminosilicates and oxides. This technique allowed to obtain a quantitative content of beryllium (in combination with other elements in the emeralds of the Mariinsky beryllium deposit and in zonal mariinskite-chrysoberyl from the chromitites of the Bazhenov ophiolite complex. All analyzes of minerals were performed on a CAMECA SX 100 electron probe microanalyzer with five wave spectrometers (IGG UB RAS. The pressure in the sample chamber was 2 × 10–4 Pa, in the electron gun region – 4 × 10–6 Pa, in wave spectrometers – 7 Pa. Accelerating voltage was 10 kV, the current of absorbed electrons on the Faraday cylinder (beam current was 100–150 nA. Diameter of the electron beam focused on the sample was 2 μm, the angle of x-ray extraction was 40°. The spectra were obtained on wave spectrometers with TAP crystal analyzers (2d = 25.745 Å, LPET (2d = 8.75 Å, LiF (2d = 4.0226 Å, and PC3 (2d = 211.4 Å, a specialized crystal for determining the content of beryllium and boron; the author carried out all the elements measurements along the Kα-lines. To determine position of the analytical peak and the background from two sides with the minimum possible spectral overlap, the author preliminarily recorded spectra on wave spectrometers. The obtained microprobe analyzes of minerals with quantitative determination of beryllium converge well with the available theoretical compositions of beryl and chrysoberyl, which indicates the high efficiency of the developed technique. By using this technique, we can relatively quickly and reliably determine the quantitative content of beryllium in natural silicates and oxides, which is an acute need for geological researchers studying the mineralogy of beryllium deposits.

  19. Measurement of total calcium in neurons by electron probe X-ray microanalysis.

    Science.gov (United States)

    Pivovarova, Natalia B; Andrews, S Brian

    2013-11-20

    In this article the tools, techniques, and instruments appropriate for quantitative measurements of intracellular elemental content using the technique known as electron probe microanalysis (EPMA) are described. Intramitochondrial calcium is a particular focus because of the critical role that mitochondrial calcium overload plays in neurodegenerative diseases. The method is based on the analysis of X-rays generated in an electron microscope (EM) by interaction of an electron beam with the specimen. In order to maintain the native distribution of diffusible elements in electron microscopy specimens, EPMA requires "cryofixation" of tissue followed by the preparation of ultrathin cryosections. Rapid freezing of cultured cells or organotypic slice cultures is carried out by plunge freezing in liquid ethane or by slam freezing against a cold metal block, respectively. Cryosections nominally 80 nm thick are cut dry with a diamond knife at ca. -160 °C, mounted on carbon/pioloform-coated copper grids, and cryotransferred into a cryo-EM using a specialized cryospecimen holder. After visual survey and location mapping at ≤-160 °C and low electron dose, frozen-hydrated cryosections are freeze-dried at -100 °C for ~30 min. Organelle-level images of dried cryosections are recorded, also at low dose, by means of a slow-scan CCD camera and subcellular regions of interest selected for analysis. X-rays emitted from ROIs by a stationary, focused, high-intensity electron probe are collected by an energy-dispersive X-ray (EDX) spectrometer, processed by associated electronics, and presented as an X-ray spectrum, that is, a plot of X-ray intensity vs. energy. Additional software facilitates: 1) identification of elemental components by their "characteristic" peak energies and fingerprint; and 2) quantitative analysis by extraction of peak areas/background. This paper concludes with two examples that illustrate typical EPMA applications, one in which mitochondrial calcium analysis

  20. Exceptional case of bone resorption in an osteo-odonto-keratoprosthesis. A scanning electron microscopy and X-ray microanalysis study

    Energy Technology Data Exchange (ETDEWEB)

    Caiazza, S.; Falcinelli, G.; Pintucci, S. (Istituto Superiore di Sanita, Rome (Italy))

    1990-01-01

    This article reports the findings of investigations on an osteo-odonto-keratoprosthesis in an eye that was enucleated owing to severe complications 12 years after implantation. Scanning electron microscopy and electron probe X-ray microanalysis showed extensive resorption of the bone that was used as a supporting element in the kind of transcorneal prosthesis developed by Strampelli. The destructive process, in addition to surgical trauma, has been associated with the early and recurrent bacterial infections relating to the presence of Staphylococcus epidermidis. The need to control the occurrence of primary bacterial infections in traumatized tissues during operations as well as further infectious situations, given the enhanced antibiotic-resistence of bacteria, is emphasized.

  1. Exceptional case of bone resorption in an osteo-odonto-keratoprosthesis. A scanning electron microscopy and X-ray microanalysis study

    International Nuclear Information System (INIS)

    Caiazza, S.; Falcinelli, G.; Pintucci, S.

    1990-01-01

    This article reports the findings of investigations on an osteo-odonto-keratoprosthesis in an eye that was enucleated owing to severe complications 12 years after implantation. Scanning electron microscopy and electron probe X-ray microanalysis showed extensive resorption of the bone that was used as a supporting element in the kind of transcorneal prosthesis developed by Strampelli. The destructive process, in addition to surgical trauma, has been associated with the early and recurrent bacterial infections relating to the presence of Staphylococcus epidermidis. The need to control the occurrence of primary bacterial infections in traumatized tissues during operations as well as further infectious situations, given the enhanced antibiotic-resistence of bacteria, is emphasized

  2. Electron probe micro-analysis of irradiated Triso-coated UO2 particles, (1)

    International Nuclear Information System (INIS)

    Ogawa, Toru; Minato, Kazuo; Fukuda, Kosaku; Ikawa, Katsuichi

    1983-11-01

    The Triso-coated low-enriched UO 2 particles were subjected to the post-irradiation electron probe micro-analysis. Observations and analyses on the amoeba effect, inclusions and solutes in the UO 2 matrix were made. In the cooler side of the particle which suffered extensive kernel migration, two significant features were observed: (1) the wake of minute particles, presumably UO 2 , left by the moving kernel in the carbon phase and (2) carbon precipitation in the pores and along the grain boundaries of the UO 2 kernel. Both features could be hardly explained by the gas-phase mechanism of carbon transport and rather suggest the solid state mechanism. Two-types of 4d-transition metal inclusions were observed: the one which was predominantly Mo with a fraction of Tc and another which was enriched with Ru and containing significant amount of Si. The Mo and Si were also found in the UO 2 matrix; the observation led to the discussion of the oxygen potential in the irradiated Triso-coated UO 2 particle. (author)

  3. Electronprobe X-ray microanalysis of biological specimens improvement of a number of quantification procedures

    International Nuclear Information System (INIS)

    Boekestein, A.

    1984-01-01

    In this thesis an investigation is described to establish which quantification procedures can be used in the X-ray microanalysis of biological specimens. Two classes of specimens have been distinguished from each other, i.e. thick specimens (opaque to the beam electrons) and thin specimens (transparent to the beam electrons). (Auth.)

  4. X-ray microanalysis in plant physiology

    International Nuclear Information System (INIS)

    Neumann, D.

    1979-01-01

    X-ray microanalysis represents a highly sensitive and modern method for the measurement of ions in the very small compartments of the cell. The limitations of X-ray microanalysis in biological objects exist in the preparation of the tissues and the quantitation of the results. In plant physiology this method has provided several surprising results and new insights for further investigations. (author)

  5. Calcium transport mechanism in molting crayfish revealed by microanalysis

    International Nuclear Information System (INIS)

    Mizuhira, V.; Ueno, M.

    1983-01-01

    Crayfish provide a good model in which to study the transport mechanism of Ca ions. During the molting stage, decalcified Ca ions are transferred into the blood and accumulate in the gastrolith epithelium, after which a gastrolith is formed on the surface of the epithelium. The gastrolith is dissolved in the stomach after molting, and the Ca is reabsorbed and redistributed throughout the newly formed exoskeleton. We studied the mechanism of Ca transport by cytochemical precipitation of Ca ions and by electron microanalysis, including X-ray microanalysis (EDX) and electron energy-loss spectroscopy (EELS), with a computer. In EDX analysis, the fine precipitates of K-antimonate in the gastrolith mitochondria clearly defined Ca with antimony; we also observed a large amount of Ca-oxalate in the mitochondria, and Ca-K X-ray pulses were clearly defined. Ca-K X-rays were also detected from fresh freeze-substituted mitochondria. Finally, we succeeded in taking a Ca-L EELS image from the mitochondria of fresh freeze-substituted thin sections. Only a very small amount of Ca was detected from the cell membrane and other organelles. Ca-adenosine triphosphatase (ATPase) and Mg-ATPase activity was also very clearly demonstrated in the mitochondria. These enzymes may play an important role in Ca metabolism

  6. Examination of chemical elements partitioning between the γ and γ′ phases in CMSX-4 superalloy using EDS microanalysis and electron tomography

    Directory of Open Access Journals (Sweden)

    Kruk Adam

    2014-01-01

    Full Text Available In the present study, the partition of chemical elements between γ and γ′ phases in CMSX-4 was investigated using EDS microanalysis and electron tomography (FIB-SEM and STEM-EDS methods. The investigation has been performed for the superalloy after standard heat treatment and the ex-service CMSX-4 turbine blade after operation for 12 700 hours and 200 starts in industrial gas turbine. The results have shown that Co, Cr and Re partition to the γ matrix, Ni and W are present in both γ and γ′ phases, while Al, Ti and Ta strongly partition to the γ′ phase. The results show the abilities of new analytical electron microscopy and electron tomography methods to characterize the microstructure and chemical composition of single crystal superalloys at the nanoscale.

  7. [Progress in the application of laser ablation ICP-MS to surface microanalysis in material science].

    Science.gov (United States)

    Zhang, Yong; Jia, Yun-hai; Chen, Ji-wen; Shen, Xue-jing; Liu, Ying; Zhao, Leiz; Li, Dong-ling; Hang, Peng-cheng; Zhao, Zhen; Fan, Wan-lun; Wang, Hai-zhou

    2014-08-01

    In the present paper, apparatus and theory of surface analysis is introduced, and the progress in the application of laser ablation ICP-MS to microanalysis in ferrous, nonferrous and semiconductor field is reviewed in detail. Compared with traditional surface analytical tools, such as SEM/EDS (scanning electron microscopy/energy dispersive spectrum), EPMA (electron probe microanalysis analysis), AES (auger energy spectrum), etc. the advantage is little or no sample preparation, adjustable spatial resolution according to analytical demand, multi-element analysis and high sensitivity. It is now a powerful complementary method to traditional surface analytical tool. With the development of LA-ICP-MS technology maturing, more and more analytical workers will use this powerful tool in the future, and LA-ICP-MS will be a super star in elemental analysis field just like LIBS (Laser-induced breakdown spectroscopy).

  8. X-ray microanalysis of psoriatic skin

    International Nuclear Information System (INIS)

    Grundin, T.G.; Roomans, G.M.; Forslind, B.; Lindberg, M.; Werner, Y.

    1985-01-01

    Electron probe x-ray microanalysis was used to study elemental distribution in uninvolved and involved skin from patients with psoriasis, and in skin from healthy controls. Significant differences were found between the involved and uninvolved psoriatic skin. In the involved skin, the concentrations of Mg, P, and K were higher in the stratum germinativum, spinosum, and granulosum, compared to the corresponding strata in uninvolved skin. Neither involved nor uninvolved psoriatic stratum germinativum differed markedly from nonpsoriatic control stratum germinativum. In uninvolved psoriatic skin only a lower level of K was noted. In comparison to uninvolved psoriatic skin, the elemental composition of the various strata of involved psoriatic skin shows a pattern typical for highly proliferative, nonneoplastic cells

  9. Quantitative X-ray microanalysis of biological specimens

    International Nuclear Information System (INIS)

    Roomans, G.M.

    1988-01-01

    Qualitative X-ray microanalysis of biological specimens requires an approach that is somewhat different from that used in the materials sciences. The first step is deconvolution and background subtraction on the obtained spectrum. The further treatment depends on the type of specimen: thin, thick, or semithick. For thin sections, the continuum method of quantitation is most often used, but it should be combined with an accurate correction for extraneous background. However, alternative methods to determine local mass should also be considered. In the analysis of biological bulk specimens, the ZAF-correction method appears to be less useful, primarily because of the uneven surface of biological specimens. The peak-to-local background model may be a more adequate method for thick specimens that are not mounted on a thick substrate. Quantitative X-ray microanalysis of biological specimens generally requires the use of standards that preferably should resemble the specimen in chemical and physical properties. Special problems in biological microanalysis include low count rates, specimen instability and mass loss, extraneous contributions to the spectrum, and preparative artifacts affecting quantitation. A relatively recent development in X-ray microanalysis of biological specimens is the quantitative determination of local water content

  10. Chemical and structural composition study through transmission and reflection electron microscopy and X-ray microanalysis of damaged duramater cardiac valves

    International Nuclear Information System (INIS)

    Verginelli, G.; Didio, L.J.A.; Puig, L.B.; Allen, D.J.; Highinson, G.H.; Zerbini, E.J.

    1982-01-01

    Ten malfunctioning durameter aortic prosthesis, excised surgically after 44 to 54 months of implantation were studied through transmission and reflection electron microscopy and X-ray microanalysis. Duramater extracted at necropsy but not used for valve prosthesis and duramater aortic prosthesis not implanted in patients were used as controls. It was concluded that homologous duramater valves present subcellular changes following implantation, with degenerating and proliferating areas which could correspond either to normal adaptation or consequence of degeneration - rebuilding which begins with implantation; it is also emphazised the need for ultramicroscopic studies in evaluating biological tissues and establishing its applicability in cardiac surgery. (M.A.C.) [pt

  11. X-ray microanalysis of black piedra.

    Science.gov (United States)

    Figueras, M J; Guarro, J

    1997-11-01

    The elements present in the fungal structures produced by Piedraia hortae in vivo and in vitro have been investigated using electron microscopy X-ray microanalysis. Phosphorus, sulphur and calcium were detected in the nodules which developed on hair and on colonies on culture. These elements belong to the extracellular material that compacts the pseudoparenchymatous organization of the fungus. They may be present due to the capacity of melanin-like pigments to sequester ions and/or they may form part of the sulphates and phosphates of the polyanionic mucopolysaccharides that constitute the extracellular material. Environmental contaminants such as aluminium, silicon and iron were detected exclusively on the surface of the nodule. They were deposited or linked to the residual molecules produced during the breakdown of the cuticular keratin. The advantages of these techniques for elucidating the chemical nature of fungal structures are discussed.

  12. Tomographic spectral imaging: microanalysis in 3D

    International Nuclear Information System (INIS)

    Kotula, P.G.; Keenan, M.R.; Michael, J.R.

    2003-01-01

    Full text: Spectral imaging, where a series of complete x-ray spectra are typically collected from a 2D area, holds great promise for comprehensive near-surface microanalysis. There are however numerous microanalysis problems where 3D chemical information is needed as well. In the SEM, some sort of sectioning (either mechanical or with a focused ion beam (FIB) tool) followed by x-ray mapping has, in the past, been utilized in an attempt to perform 3D microanalysis. Reliance on simple mapping has the potential to miss important chemical features as well as misidentify others. In this paper we will describe the acquisition of serial-section tomographic spectral images (TSI) with a dual-beam FIB/SEM equipped with an EDS system. We will also describe the application of a modified version of our multivariate statistical analysis algorithms to TSIs. Serial sectioning was performed with a FEI DB-235 FIB/SEM. Firstly, the specimen normal was tilted to the optic axis of the FIB column and a trench was milled into the surface of the specimen. A second trench was then milled perpendicular to the first to provide visibility of the entire analysis surface to the x-ray detector. In addition, several fiducial markers were milled into the surface to allow for alignment from slice to slice. The electron column is at an angle of 52 deg to the ion column so the electron beam can 'see' the analysis surface milled by the FIB with no additional specimen tilting or rotation. Likewise the x-ray detector is at a radial angle of 45 deg to the plane of the electron and ion columns (about the electron column) and a take-off-angle of 35 deg with respect to an untilted specimen so it can 'see' the analysis surface as well with no additional sample tilting or rotation. Spectral images were acquired from regions 40 μm wide and 20μm deep for each slice. Approximately 1μm/slice was milled and 10-12 total slices were cut. Spectral images were acquired with a Thermo NORAN Vantage (Digital imaging

  13. Electronic Resource Management and Design

    Science.gov (United States)

    Abrams, Kimberly R.

    2015-01-01

    We have now reached a tipping point at which electronic resources comprise more than half of academic library budgets. Because of the increasing work associated with the ever-increasing number of e-resources, there is a trend to distribute work throughout the library even in the presence of an electronic resources department. In 2013, the author…

  14. Inner-shell electron spectroscopy for microanalysis

    International Nuclear Information System (INIS)

    Joy, D.C.; Maher, D.M.

    1979-01-01

    The transmission electron energy-loss spectrum shows characteristic edges corresponding to the excitation of inner-shell electrons of atoms in a thin sample. Analysis of these edges provides detailed chemical, structural, and electronic data from the radiated volume. By combining electron spectroscopy and electron microscopy, this microanalytical technique can be performed in conjunction with high-resolution imaging of the sample. It is shown that this approach has advantages of sensitivity, spatial resolution, and convenience over other comparable techniques. 7 figures

  15. Recent applications of X-ray microanalysis in muscle pathology

    International Nuclear Information System (INIS)

    Wroblewski, R.; Edstrom, L.

    1984-01-01

    X-ray microanalysis of single muscle fibres visualized in the scanning- and scanning-transmission mode of electron microscopy has been applied to human muscle biopsies to quantify changes of intracellular elements in different muscle disorders. To detect elements representing diffusible ions, cryofixation and cryosectioning was performed and analyses were conducted on freeze-dried cryosections 6μm thick. Changes in the concentration of elements were found to differentiate certain muscular disorders. A large increase in sodium (Na) and chlorine (Cl), and a decrease in potassium (K) was typical of myotubular myopathy, while a moderate increase in Na and Cl was found in central core disease and nemaline myopathy

  16. Lipovitellin-phosvitin crystals with orthorhombic features: thin-section electron microscopy, gel electrophoresis, and microanalysis in teleost and amphibian yolk platelets and a comparison with other vertebrates

    International Nuclear Information System (INIS)

    Lange, R.H.; Richter, H.P.; Riehl, R.; Zierold, K.; Trandaburu, T.; Magdowski, G.

    1983-01-01

    Yolk-platelet crystals in the teleosts Pelvicachromis pulcher and Noemacheilus barbatulus and the amphibians Xenopus laevis, Rana temporaria, R. esculenta, and Triturus sp. have been studied by electron diffraction and imaging using a standardized processing (glutaraldehyde-osmium tetroxide fixation, glutaraldehyde-urea embedding, thin-section staining), by X-ray microanalysis, and sodium dodecyl sulfate-polyacrylamide gel electrophoresis of their constituents. The crystal lattice is orthorhombic having. Crystal images in the three axial projections point to the presence of space group P212121 (or an approximation of it since the lipovitellin dimers cannot be fully equivalent in some cases), to differences between the phosvitins of the two teleosts, and to a highly unusual stain exclusion from large crystal constituents interpreted as representing lipovitellin dimers. Microanalysis in ultrathin cryosections and other preparations revealed K and Cl to be the prominent ions in the crystals (and in the superficial layer of the platelet). Gel electrophoresis (including data of cyclostomes) showed considerable molecular variations despite a closely similar crystal architecture, emphasizing a physiological significance of the architecture, which may have remained conserved for nearly 400 million years according to paleontologic views

  17. Electron probe X-ray microanalysis of boar and inobuta testes after the Fukushima accident

    International Nuclear Information System (INIS)

    Yamashiro, Hideaki; Abe, Yasuyuki; Hayashi, Gohei; Urushihara, Yusuke; Kuwahara, Yoshikazu; Suzuki, Masatoshi; Kobayashi, Jin; Kino, Yasuyuki; Fukuda, Tomokazu; Tong, Bin; Takino, Sachio; Sugano, Yukou; Sugimura, Satoshi; Yamada, Takahisa; Isogai, Emiko; Fukumoto, Manabu

    2015-01-01

    We aimed to investigate the effect of chronic radiation exposure associated with the Fukushima Daiichi Nuclear Power Plant (FNPP) accident on the testes of boar and inobuta (a hybrid of Sus scrofa and Sus scrofa domestica). This study examined the contamination levels of radioactive caesium (Cs), especially 134 Cs and 137 Cs, in the testis of both boar and inobuta during 2012, after the Fukushima accident. Morphological analysis and electron-probe X-ray microanalysis (EPMA) were also undertaken on the testes. The 134 Cs and 137 Cs levels were 6430 ± 23 and 6820 ± 32 Bq/kg in the boar testes, and 755 ± 13 and 747 ± 17 Bq/kg in the inobuta testes, respectively. The internal and external exposure of total 134 Cs and 137 Cs in the boar testes were 47.1 mGy and 176.2 mGy, respectively, whereas in the inobuta testes, these levels were 6.09 mGy and 59.8 mGy, respectively. Defective spermatogenesis was not detected by the histochemical analysis of radiation-exposed testes for either animal. In neither animal were Cs molecules detected, using EPMA. In conclusion, we showed that adverse radiation-induced effects were not detected in the examined boar and inobuta testes following the chronic radiation exposure associated with the FNPP accident

  18. X-ray microanalysis in cryosections of natively frozen Paramecium caudatum with regard to ion distribution in ciliates

    International Nuclear Information System (INIS)

    Schmitz, M.; Meyer, R.; Zierold, K.

    1985-01-01

    Cells of Paramecium caudatum were shock-frozen without pretreatment for cryoultramicrotomy and freeze-dried for subsequent X-ray microanalysis. Na, Mg, P, S, Cl, K, and Ca were detected in different amounts in several subcellular compartments. In particular, calcium was localized below the cell surface (pellicle). Trichocysts were found to contain significant amounts of Na in their base but not in the tip. Na, Mg, P, S, Cl, K, Ca were found in electron dense deposits within the lumen of the contractile vacuole. A small K concentration was found in the cytoplasm and in the mitochondria. X-ray microanalysis of the element distribution in different subcellular compartments provides information for the understanding of cellular functions such as exocytosis, locomotion, and ion regulation

  19. Vision of new generation CRMs for QC of microanalysis

    International Nuclear Information System (INIS)

    Tian Weizhi

    2005-01-01

    Direct analysis of ever smaller solid samples has become one of the trends in modern analytical science, in coping with the increasing requirements from life, materials, environment, and other frontier scientific fields. Due to the lack of natural matrix CRMs certified at matched sample size levels, however, quantitative calibration and quality control have long been a bottleneck of microanalysis. CRMs of new generation are therefore called for to make solid sampling microanalysis an accurately quantitative and quality-controllable technique. In this paper, an approach is proposed to use a combination of several nuclear analytical techniques in the certification of RMs suitable for QC of analyses at sub-ng sample size levels. The technical procedures, the major problems, and the possible format of certificates of the new generation CRMs, and the outliik of the establishment of QC system for microanalysis are described. The CRMs of current generation have played an important role in the quality of analysis, especially trace analysis, and in turn in the development of related scientific fields in 20 th century. It may be reasonably predicted that the new generation CRMs will play the similar role in the quality of microanalysis, and in turn in relevant frontier scientific fields in 21 st century. Nuclear analytical techniques have made, and will continue to make, unique contributions to both generations of CRMs.

  20. An EPMA study on KNbO3 and NaNbO3 single crystals - potential reference materials for quantitative microanalysis

    International Nuclear Information System (INIS)

    Samardzzija, Z.; Bernik, S.; Malic, B.; Ceh, M.; Marinenko, R.B.

    2004-01-01

    Single crystals of KNbO 3 and NaNbO 3 were selected from the limited number of suitable alkali compounds that are available and evaluated as possible reference materials for the electron-probe microanalysis (EPMA) of alkaline niobates with a composition described by the general formula K 1-x Na x NbO 3 . The EPMA study verified that KNbO 3 and NaNbO 3 single crystals are stable under the electron beam and compositionally homogeneous. A quantitative microanalysis confirmed the composition of pure KNbO 3 , while the NaNbO 3 crystal contained 0.3 mass fraction % of Ca. A significant improvement in the accuracy of the quantitative EPMA of polycrystalline potassium-sodium niobates was achieved using these single crystals as standards. The crystals can also be useful as reference materials for the analysis of sodium and potassium in other materials. (author)

  1. Scanning electron microscopy and micro-analyses

    International Nuclear Information System (INIS)

    Brisset, F.; Repoux, L.; Ruste, J.; Grillon, F.; Robaut, F.

    2008-01-01

    Scanning electron microscopy (SEM) and the related micro-analyses are involved in extremely various domains, from the academic environments to the industrial ones. The overall theoretical bases, the main technical characteristics, and some complements of information about practical usage and maintenance are developed in this book. high-vacuum and controlled-vacuum electron microscopes are thoroughly presented, as well as the last generation of EDS (energy dispersive spectrometer) and WDS (wavelength dispersive spectrometer) micro-analysers. Beside these main topics, other analysis or observation techniques are approached, such as EBSD (electron backscattering diffraction), 3-D imaging, FIB (focussed ion beams), Monte-Carlo simulations, in-situ tests etc.. This book, in French language, is the only one which treats of this subject in such an exhaustive way. It represents the actualized and totally updated version of a previous edition of 1979. It gathers the lectures given in 2006 at the summer school of Saint Martin d'Heres (France). Content: 1 - electron-matter interactions; 2 - characteristic X-radiation, Bremsstrahlung; 3 - electron guns in SEM; 4 - elements of electronic optics; 5 - vacuum techniques; 6 - detectors used in SEM; 7 - image formation and optimization in SEM; 7a - SEM practical instructions for use; 8 - controlled pressure microscopy; 8a - applications; 9 - energy selection X-spectrometers (energy dispersive spectrometers - EDS); 9a - EDS analysis; 9b - X-EDS mapping; 10 - technological aspects of WDS; 11 - processing of EDS and WDS spectra; 12 - X-microanalysis quantifying methods; 12a - quantitative WDS microanalysis of very light elements; 13 - statistics: precision and detection limits in microanalysis; 14 - analysis of stratified samples; 15 - crystallography applied to EBSD; 16 - EBSD: history, principle and applications; 16a - EBSD analysis; 17 - Monte Carlo simulation; 18 - insulating samples in SEM and X-ray microanalysis; 18a - insulating

  2. Nuclear analytical methods in quality control of microanalysis

    International Nuclear Information System (INIS)

    Tian Weizhi

    2004-01-01

    Quantitative calibration and quality control have been a major bottleneck in microanalysis due to the lack of natural-matrix CRMs certified at sample sizes compatible with those of unknown samples. A solution is described to characterize sampling behavior for individual elements, so as to identify elements homogeneous enough at stated sample size levels in given CRMs/RMs. By using a combination of several nuclear analytical techniques, INAA-EDXRF-μPIXE, sampling behavior for individual elements can be characterized at sample size levels from grams down to pg. Natural-matrix CRMs specifically for QC of microanalysis may thus be created. Additional information in certificates of these new generation CRMs is imagined. (author)

  3. Rigorous quantitative elemental microanalysis by scanning electron microscopy/energy dispersive x-ray spectrometry (SEM/EDS) with spectrum processing by NIST DTSA-II

    Science.gov (United States)

    Newbury, Dale E.; Ritchie, Nicholas W. M.

    2014-09-01

    Quantitative electron-excited x-ray microanalysis by scanning electron microscopy/silicon drift detector energy dispersive x-ray spectrometry (SEM/SDD-EDS) is capable of achieving high accuracy and high precision equivalent to that of the high spectral resolution wavelength dispersive x-ray spectrometer even when severe peak interference occurs. The throughput of the SDD-EDS enables high count spectra to be measured that are stable in calibration and resolution (peak shape) across the full deadtime range. With this high spectral stability, multiple linear least squares peak fitting is successful for separating overlapping peaks and spectral background. Careful specimen preparation is necessary to remove topography on unknowns and standards. The standards-based matrix correction procedure embedded in the NIST DTSA-II software engine returns quantitative results supported by a complete error budget, including estimates of the uncertainties from measurement statistics and from the physical basis of the matrix corrections. NIST DTSA-II is available free for Java-platforms at: http://www.cstl.nist.gov/div837/837.02/epq/dtsa2/index.html).

  4. Complementary microanalysis of Zn, Mn and Fe in the chelicera of spiders and scorpions using scanning MeV-ion and electron microprobes

    International Nuclear Information System (INIS)

    Schofield, R.; Lefevre, H.; Shaffer, M.

    1989-01-01

    Energy-loss scanning transmission ion microscopy (ELSTIM or just STIM), PIXE and electron microprobe techniques are used to investigate certain minor element accumulations in a few spiders and scorpions. STIM and PIXE are used to survey the unsectioned specimens, while electron microprobe techniques are used for higher resolution investigations of several sections of the specimens. Concentration values measured using STIM and PIXE are found to be in satisfactory agreement with those measured using electron probe microanalysis. A garden spider Araneous diadematus is found to contain high concentrations of zinc in a thin layer near the surface of its fangs (reaching 23% of dry weight), and manganese in its marginal teeth (about 5% of dry weight). A wolf spider Alopecosa kochi is found to have similar concentrations of zinc in a layer near the surface of it's fang, and concentrations of manganese reaching 1.5% in a layer beneath the zinc containing layer. A scorpion Centruroides sp. is found to contain high concentrations of iron (reaching 8%) and zinc (reaching 24%) in the tips of teeth on the cheliceral fingers, and manganese (about 5%) in the stinger. The hypothesis that these elements simply harden the cuticle does not appear to explain their segregation patterns. (orig.)

  5. Site determination of Ni atoms in Cu-Al-Ni shape memory alloys by electron channelling enhanced microanalysis

    International Nuclear Information System (INIS)

    Nakata, Yoshiyuki; Tadaki, Tsugio; Shimizu, Ken-ichi

    1990-01-01

    The crystallographic site of Ni atoms in the parent phase of differently heat-treated Cu-28.6Al-3.7Ni (at.%) shape memory alloys has been examined by electron channelling enhanced microanalysis (ALCHEMI) in order to clarify effects of heat-treatments on the Ni atom site and M s temperature. The heat-treatments were as follows: (a) Quenching into a 10% NaOH solution at 263 K, (b) Quenching into hot water at 363 K and (c) Aging at 523 K for 3.6 ks after treatment (b). The M s temperatures of specimens (a), (b) and (c) were 158, 185 and 259 K, respectively, increasing with lowering quenching rate or aging. ALCHEMI revealed that Ni atoms occupied an identical site in all the three kinds of specimens: The Ni atoms were located at the nearest neighbor sites around Al atoms. This preferential occupation of Ni atoms was attributed to the strong binding force between Ni and Al atoms. Thus, the change in M s temperature due to different heat-treatments was not directly related to the crystallographic site of Ni atoms, but might be caused by the ordering between the next nearest neighbor Cu and Al atoms. (author)

  6. Electron-probe microanalysis: x-ray spectroscopy

    International Nuclear Information System (INIS)

    1987-01-01

    The main principles on X-ray, energy and wave length dispersive spectroscopy are reviewed. In order to allow the choice of the best operating conditions, the importance of the regulation and control systems is underlined. Emission theory, X-rays nature and its interaction with matter and electrons in the matter is shown. The structure, operating procedures and necessary electronics (single channel - analysis chain) automatic-control system for the threshold-energies discrimination and the energy distribution visualization) associated to the wavelength dispersive spectroscopy are described. The focusing control, resolution, influence of chemical bonds and multilayer-structure monochromators relaled to wavelength dispersive spectroscopy are studied. Concerning the energy-dispersive spectroscopy, the detector, preamplifier, amplifier, analog-digital converter, as well as the utilization and control of the spectrometer are described. Problems and instrumental progress on energy-dispersive spectroscopy related to the electronic-noise control, charge collection and light-elements detection are discussed [fr

  7. Electronic Resource Management Systems

    Directory of Open Access Journals (Sweden)

    Mark Ellingsen

    2004-10-01

    Full Text Available Computer applications which deal with electronic resource management (ERM are quite a recent development. They have grown out of the need to manage the burgeoning number of electronic resources particularly electronic journals. Typically, in the early years of e-journal acquisition, library staff provided an easy means of accessing these journals by providing an alphabetical list on a web page. Some went as far as categorising the e-journals by subject and then grouping the journals either on a single web page or by using multiple pages. It didn't take long before it was recognised that it would be more efficient to dynamically generate the pages from a database rather than to continually edit the pages manually. Of course, once the descriptive metadata for an electronic journal was held within a database the next logical step was to provide administrative forms whereby that metadata could be manipulated. This in turn led to demands for incorporating more information and more functionality into the developing application.

  8. Electronic Resources Management Project Presentation 2012

    KAUST Repository

    Ramli, Rindra M.

    2012-11-05

    This presentation describes the electronic resources management project undertaken by the KAUST library. The objectives of this project is to migrate information from MS Sharepoint to Millennium ERM module. One of the advantages of this migration is to consolidate all electronic resources into a single and centralized location. This would allow for better information sharing among library staff.

  9. Scanning electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Cox, B. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    1970-05-15

    The JSM-11 scanning electron microscope at CRNL has been used extensively for topographical studies of oxidized metals, fracture surfaces, entomological and biological specimens. A non-dispersive X-ray attachment permits the microanalysis of the surface features. Techniques for the production of electron channeling patterns have been developed. (author)

  10. PRINCIPLES OF CONTENT FORMATION EDUCATIONAL ELECTRONIC RESOURCE

    Directory of Open Access Journals (Sweden)

    О Ю Заславская

    2017-12-01

    Full Text Available The article considers modern possibilities of information and communication technologies for the design of electronic educational resources. The conceptual basis of the open educational multimedia system is based on the modular architecture of the electronic educational resource. The content of the electronic training module can be implemented in several versions of the modules: obtaining information, practical exercises, control. The regularities in the teaching process in modern pedagogical theory are considered: general and specific, and the principles for the formation of the content of instruction at different levels are defined, based on the formulated regularities. On the basis of the analysis, the principles of the formation of the electronic educational resource are determined, taking into account the general and didactic patterns of teaching.As principles of the formation of educational material for obtaining information for the electronic educational resource, the article considers: the principle of methodological orientation, the principle of general scientific orientation, the principle of systemic nature, the principle of fundamentalization, the principle of accounting intersubject communications, the principle of minimization. The principles of the formation of the electronic training module of practical studies in the article include: the principle of systematic and dose based consistency, the principle of rational use of study time, the principle of accessibility. The principles of the formation of the module for monitoring the electronic educational resource can be: the principle of the operationalization of goals, the principle of unified identification diagnosis.

  11. Implementing CORAL: An Electronic Resource Management System

    Science.gov (United States)

    Whitfield, Sharon

    2011-01-01

    A 2010 electronic resource management survey conducted by Maria Collins of North Carolina State University and Jill E. Grogg of University of Alabama Libraries found that the top six electronic resources management priorities included workflow management, communications management, license management, statistics management, administrative…

  12. Clinimetrics and clinical psychometrics: macro- and micro-analysis.

    Science.gov (United States)

    Tomba, Elena; Bech, Per

    2012-01-01

    Clinimetrics was introduced three decades ago to specify the domain of clinical markers in clinical medicine (indexes or rating scales). In this perspective, clinical validity is the platform for selecting the various indexes or rating scales (macro-analysis). Psychometric validation of these indexes or rating scales is the measuring aspect (micro-analysis). Clinical judgment analysis by experienced psychiatrists is included in the macro-analysis and the item response theory models are especially preferred in the micro-analysis when using the total score as a sufficient statistic. Clinical assessment tools covering severity of illness scales, prognostic measures, issues of co-morbidity, longitudinal assessments, recovery, stressors, lifestyle, psychological well-being, and illness behavior have been identified. The constructive dialogue in clinimetrics between clinical judgment and psychometric validation procedures is outlined for generating developments of clinical practice in psychiatry. Copyright © 2012 S. Karger AG, Basel.

  13. X-ray microanalysis of single and cultured cells

    International Nuclear Information System (INIS)

    Wroblewski, J.; Roomans, G.M.

    1984-01-01

    X-ray microanalysis of single or cultured cells is often a useful alternative or complement to the analysis of the corresponding tissue. It also allows the analysis of individual cells in a cell population. Preparation for X-ray microanalysis poses a number of typical problems. Suspensions of single cells can be prepared by either of two pathways: (1) washing - mounting - drying, or (2) centrifugation - freezing or fixation - sectioning. The washing step in the preparation of single or cultured cells presents the most severe problems. Cultured cells are generally grown on a substrate that is compatible with both the analysis and the culture, washed and dried. In some cases, sectioning of cultured cell monolayers has been performed. Special problems in quantitative analysis occur in those cases where the cells are analyzed on a thick substrate, since the substrate contributes to the spectral background

  14. Managing electronic resources a LITA guide

    CERN Document Server

    Weir, Ryan O

    2012-01-01

    Informative, useful, current, Managing Electronic Resources: A LITA Guide shows how to successfully manage time, resources, and relationships with vendors and staff to ensure personal, professional, and institutional success.

  15. Electron microscopy methods in studies of cultural heritage sites

    Science.gov (United States)

    Vasiliev, A. L.; Kovalchuk, M. V.; Yatsishina, E. B.

    2016-11-01

    The history of the development and application of scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy-dispersive X-ray microanalysis (EDXMA) in studies of cultural heritage sites is considered. In fact, investigations based on these methods began when electron microscopes became a commercial product. Currently, these methods, being developed and improved, help solve many historical enigmas. To date, electron microscopy combined with microanalysis makes it possible to investigate any object, from parchment and wooden articles to pigments, tools, and objects of art. Studies by these methods have revealed that some articles were made by ancient masters using ancient "nanotechnologies"; hence, their comprehensive analysis calls for the latest achievements in the corresponding instrumental methods and sample preparation techniques.

  16. Microanalysis in Music Therapy: Introduction and Theoretical basis

    DEFF Research Database (Denmark)

    Wosch, Thomas; Wigram, Tony

    2007-01-01

    In the context of music therapy, microanalysis is the detailed analysis of that short period of time during a music therapy session during which some kind of significant change takes place. These moments are crucial to the therapeutic process, and there is increasing interest amongst music therap...... provides a wealth of important theoretical and practical information for music therapy clinicians, educators and students.......In the context of music therapy, microanalysis is the detailed analysis of that short period of time during a music therapy session during which some kind of significant change takes place. These moments are crucial to the therapeutic process, and there is increasing interest amongst music...... therapists in understanding how they come about and whether there are ways of initiating them. The contributors to this groundbreaking book look at methods of micro process analyses used in a variety of music therapy contexts, both clinical and research-based. They outline their methods, which include using...

  17. Contribution to the physical modeling of the actinide characterization by electron probe microanalysis

    International Nuclear Information System (INIS)

    Moy, Aurelien

    2014-01-01

    Electron probe microanalysis (EPMA) is used to quantify with a high accuracy the amount of different elements present on a sample of unknown composition. EPMA is largely used to quantify the amount of actinides present in fresh and irradiated fuels, to manage waste disposal and to date rocks. However, quantitative EPMA is not always possible to achieve for these materials due to the lack of suitable reference standards for the radionuclides. To overcome this difficulty, standard-less methods of analysis are employed with mean of virtual calculated standards. These calculated standards are generally obtained from empirical formulae based on experimental extrapolations or from theoretical calculations that require physical parameters which are poorly known as it is the case for the X-ray production cross section. The accurate knowledge of these cross sections is required in many applications such as in particle transport code and in Monte Carlo simulations. The computer simulations are widely used in the medical field and particularly in medical imaging and in electron beam therapy. In the field of astronomy, these data are used to perform simulations that predict the compositions of stars and galactic clouds, and the formation of planetary systems. In the present work, L- and M-shell absolute x-ray production cross sections were determined experimentally for elements lead, thorium and uranium by electron impact using ultrathin self-supporting targets with thickness varying from 0.2 to 8 nm. The measured cross sections have been compared, with the distorted-wave Born approximation (DWBA) calculated by Bote et al. and with the predictions of analytical formulae widely used in practical applications. For the conversion of inner-shell ionization cross sections into x-ray production cross sections, atomic relaxation parameters were extracted from the literature. The predictions of the DWBA calculations are in excellent agreement with our measured x-ray production cross

  18. Physical methods for studying minerals and solid materials: X-ray, electron and neutron diffraction; scanning and transmission electron microscopy; X-ray, electron and ion spectrometry

    International Nuclear Information System (INIS)

    Eberhart, J.-P.

    1976-01-01

    The following topics are discussed: theoretical aspects of radiation-matter interactions; production and measurement of radiations (X rays, electrons, neutrons); applications of radiation interactions to the study of crystalline materials. The following techniques are presented: X-ray and neutron diffraction, electron microscopy, electron diffraction, X-ray fluorescence analysis, electron probe microanalysis, surface analysis by electron emission spectrometry (ESCA and Auger electrons), scanning electron microscopy, secondary ion emission analysis [fr

  19. Characterization of high Tc materials and devices by electron microscopy

    National Research Council Canada - National Science Library

    Browning, Nigel D; Pennycook, Stephen J

    2000-01-01

    ..., and microanalysis by scanning transmission electron microscopy. Ensuing chapters examine identi®cation of new superconducting compounds, imaging of superconducting properties by lowtemperature scanning electron microscopy, imaging of vortices by electron holography and electronic structure determination by electron energy loss spectro...

  20. How does microanalysis of mother-infant communication inform maternal sensitivity and infant attachment?

    Science.gov (United States)

    Beebe, Beatrice; Steele, Miriam

    2013-01-01

    Microanalysis research on 4-month infant-mother face-to-face communication operates like a "social microscope" and identifies aspects of maternal sensitivity and the origins of attachment with a more detailed lens. We hope to enhance a dialogue between these two paradigms, microanalysis of mother-infant communication and maternal sensitivity and emerging working models of attachment. The prediction of infant attachment from microanalytic approaches and their contribution to concepts of maternal sensitivity are described. We summarize aspects of one microanalytic study by Beebe and colleagues published in 2010 that documents new communication patterns between mothers and infants at 4 months that predict future disorganized (vs. secure) attachment. The microanalysis approach opens up a new window on the details of the micro-processes of face-to-face communication. It provides a new, rich set of behaviors with which to extend our understanding of the origins of infant attachment and of maternal sensitivity.

  1. Determination of UTW K/sub XSi/ factors for low atomic number microanalysis: A systematic approach

    International Nuclear Information System (INIS)

    Krishnan, K.M.; Echer, C.J.

    1987-07-01

    A systematic measurement of experimental K/sub XSi/ factors, with particular emphasis on low Z microanalysis (6 ≤ 7 ≤ 32), at 200 kV for a KEVEX UTW Si(Li) detector fitted to a JEOL 200CX analytical microscope, using a variety of high purity standards has been carried out. Under normal operating conditions of a LaB 6 filament, it is shown that absorption in the specimen is very critical, particularly for heavy element matrices, and sample thicknesses need to be measured for accurate microanalysis of low Z elements (C,N,O). Using these measured K/sub XSi/ factors, quantitative UTW-EDX microanalysis has been routinely extended to carbon. 21 refs

  2. Electron microscopy methods in studies of cultural heritage sites

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, A. L., E-mail: a.vasiliev56@gmail.com; Kovalchuk, M. V.; Yatsishina, E. B. [National Research Centre “Kurchatov Institute” (Russian Federation)

    2016-11-15

    The history of the development and application of scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy-dispersive X-ray microanalysis (EDXMA) in studies of cultural heritage sites is considered. In fact, investigations based on these methods began when electron microscopes became a commercial product. Currently, these methods, being developed and improved, help solve many historical enigmas. To date, electron microscopy combined with microanalysis makes it possible to investigate any object, from parchment and wooden articles to pigments, tools, and objects of art. Studies by these methods have revealed that some articles were made by ancient masters using ancient “nanotechnologies”; hence, their comprehensive analysis calls for the latest achievements in the corresponding instrumental methods and sample preparation techniques.

  3. Electron microscopy methods in studies of cultural heritage sites

    International Nuclear Information System (INIS)

    Vasiliev, A. L.; Kovalchuk, M. V.; Yatsishina, E. B.

    2016-01-01

    The history of the development and application of scanning electron microscopy (SEM), transmission electron microscopy (TEM), and energy-dispersive X-ray microanalysis (EDXMA) in studies of cultural heritage sites is considered. In fact, investigations based on these methods began when electron microscopes became a commercial product. Currently, these methods, being developed and improved, help solve many historical enigmas. To date, electron microscopy combined with microanalysis makes it possible to investigate any object, from parchment and wooden articles to pigments, tools, and objects of art. Studies by these methods have revealed that some articles were made by ancient masters using ancient “nanotechnologies”; hence, their comprehensive analysis calls for the latest achievements in the corresponding instrumental methods and sample preparation techniques.

  4. Investigation of enviromental objects by microanalysis methods

    OpenAIRE

    Osīte, Agnese

    2008-01-01

    Investigation of environmental objects by microanalysis methods AEROSOL PARTICLES, SOOT, METALLIC ELEMENTS, WATER, PINE NEEDLES, STRIPPING POTENTIOMETRY, INDUCTIVELY COUPLED PLASMA MASSPECTROMETRY, ENERGY DISPERIVE X-RAY FLUORESCENCE Performing the fractionated sampling by both commercially available and laboratory constructed devices, mass concentrations of four fractions of solid particles PM10, PM2.5-10, PM2.5 and PM1 were determined. Mass concentrations of soot were ...

  5. Gender Analysis Of Electronic Information Resource Use: The Case ...

    African Journals Online (AJOL)

    Based on the findings the study concluded that access and use of electronic information resources creates a “social digital divide” along gender lines. The study ... Finally, the library needs to change its marketing strategies on the availability of electronic information resources to increase awareness of these resources.

  6. How Does Microanalysis of Mother-Infant Communication Inform Maternal Sensitivity and Infant Attachment?

    Science.gov (United States)

    Beebe, Beatrice; Steele, Miriam

    2013-01-01

    Microanalysis research on 4-month mother-infant face-to-face communication operates like a “social microscope” and identifies aspects of maternal sensitivity and the origins of attachment with a more detailed lens. We hope to enhance a dialogue between these two paradigms, microanalysis of mother-infant communication and maternal sensitivity and emerging working models of attachment. The prediction of infant attachment from microanalytic approaches and their contribution to concepts of maternal sensitivity are described. We summarize aspects of one microanalytic study by Beebe and colleagues (2010) that documents new communication patterns between mothers and infants at 4 months that predict future disorganized (vs. secure) attachment. The microanalysis approach opens up a new window on the details of the micro-processes of face-to-face communication. It provides a new, rich set of behaviors with which to extend our understanding of the origins of infant attachment and of maternal sensitivity. PMID:24299136

  7. Users satisfaction with electronic information resources and services ...

    African Journals Online (AJOL)

    This study investigated users satisfaction on the use of electronic information resources and services in MTN Net libraries in ABU & UNIBEN. Two objectives and one null hypotheses were formulated and tested with respect to the users' satisfaction on electronic information resources and services in MTN Net libraries in ...

  8. Transmission electron microscopy physics of image formation and microanalysis

    CERN Document Server

    Reimer, Ludwig

    1997-01-01

    Transmission Electron Microscopy presents the theory of image and contrast formation, and the analytical modes in transmission electron microscopy. The principles of particle and wave optics of electrons are described. Electron-specimen interactions are discussed for evaluating the theory of scattering and phase contrast. Also discussed are the kinematical and dynamical theories of electron diffraction and their applications for crystal-structure analysis and imaging of lattices and their defects. X-ray micronanalysis and electron energy-loss spectroscopy are treated as analytical methods. Specimen damage and contamination by electron irradiation limits the resolution for biological and some inorganic specimens. This fourth edition includes discussion of recent progress, especially in the area of Schottky emission guns, convergent-beam electron diffraction, electron tomography, holography and the high resolution of crystal lattices.

  9. Trace microanalysis of uranium in Indian tea samples

    International Nuclear Information System (INIS)

    Bansal, V.; Prasad, Rajendra

    1991-01-01

    The microscopic detection of radiation damage in plastic detectors has been used for the microanalysis of uranium contents in tea samples, commercially available in the market. The uranium concentration has been found to vary from 0.007±0.0001 to 0.12±0.001 ppm in various tea leaves. (author). 6 refs., 1 tab

  10. Microanalysis by spectroscopy of transmitted electron energy losses

    International Nuclear Information System (INIS)

    Colliex, C.; Trebbia, P.

    1978-01-01

    Among the various signals which, in a transmission electron microscope, result from the interactions between the primary beam of well defined energy E 0 and the sample, the spectrum of the energy distribution of the electrons transmitted contains useful informations on the chemical and physical properties of the sample. Consequently the adaptation of an energy dispersive system on an electron microscope enables new fields of research to be investigated, particularly a localised chemical analysis technique with a space resolution scale equal to that of the electron microscope. It is this second aspect that we suggest describing in particular here. Already, this technique appears to be indispensable in the problems arising from the analysis of very small quantities of matter: detection limits in the order of 10 -19 to 10 -20 g (around 100 to 1000 atoms) would seem to be resonably possible [fr

  11. Transmission electron microscopy physics of image formation and microanalysis

    CERN Document Server

    Reimer, Ludwig

    1984-01-01

    The aim of this book is to outline the physics of image formation, electron­ specimen interactions and image interpretation in transmission electron mic­ roscopy. The book evolved from lectures delivered at the University of Munster and is a revised version of the first part of my earlier book Elek­ tronenmikroskopische Untersuchungs- und Priiparationsmethoden, omitting the part which describes specimen-preparation methods. In the introductory chapter, the different types of electron microscope are compared, the various electron-specimen interactions and their applications are summarized and the most important aspects of high-resolution, analytical and high-voltage electron microscopy are discussed. The optics of electron lenses is discussed in Chapter 2 in order to bring out electron-lens properties that are important for an understanding of the function of an electron microscope. In Chapter 3, the wave optics of elec­ trons and the phase shifts by electrostatic and magnetic fields are introduced; Fresne...

  12. Scanning electron microscopy physics of image formation and microanalysis

    CERN Document Server

    Reimer, Ludwig

    1985-01-01

    The aim of this book is to outline the physics of image formation, electron­ specimen interactions, imaging modes, the interpretation of micrographs and the use of quantitative modes "in scanning electron microscopy (SEM). lt forms a counterpart to Transmission Electron Microscopy (Vol. 36 of this Springer Series in Optical Sciences) . The book evolved from lectures delivered at the University of Münster and from a German text entitled Raster-Elektronenmikroskopie (Springer-Verlag), published in collaboration with my colleague Gerhard Pfefferkorn. In the introductory chapter, the principles of the SEM and of electron­ specimen interactions are described, the most important imaging modes and their associated contrast are summarized, and general aspects of eiemental analysis by x-ray and Auger electron emission are discussed. The electron gun and electron optics are discussed in Chap. 2 in order to show how an electron probe of small diameter can be formed, how the elec­ tron beam can be blanked at high fre...

  13. A flexible and accurate quantification algorithm for electron probe X-ray microanalysis based on thin-film element yields

    Science.gov (United States)

    Schalm, O.; Janssens, K.

    2003-04-01

    Quantitative analysis by means of electron probe X-ray microanalysis (EPXMA) of low Z materials such as silicate glasses can be hampered by the fact that ice or other contaminants build up on the Si(Li) detector beryllium window or (in the case of a windowless detector) on the Si(Li) crystal itself. These layers act as an additional absorber in front of the detector crystal, decreasing the detection efficiency at low energies (philosophy often employed in quantitative analysis of X-ray fluorescence (XRF) and proton-induced X-ray emission (PIXE) data. This approach is based on the (experimental) determination of thin-film element yields, rather than starting from infinitely thick and single element calibration standards. These thin-film sensitivity coefficients can also be interpolated to allow quantification of elements for which no suitable standards are available. The change in detector efficiency can be monitored by collecting an X-ray spectrum of one multi-element glass standard. This information is used to adapt the previously determined thin-film sensitivity coefficients to the actual detector efficiency conditions valid on the day that the experiments were carried out. The main advantage of this method is that spectra collected from the standards and from the unknown samples should not be acquired within a short period of time. This new approach is evaluated for glass and metal matrices and is compared with a standard ZAF method.

  14. Organizational matters of competition in electronic educational resources

    Directory of Open Access Journals (Sweden)

    Ирина Карловна Войтович

    2015-12-01

    Full Text Available The article examines the experience of the Udmurt State University in conducting competitions of educational publications and electronic resources. The purpose of such competitions is to provide methodological support to educational process. The main focus is on competition of electronic educational resources. The technology of such contests is discussed through detailed analysis of the main stages of the contest. It is noted that the main task of the preparatory stage of the competition is related to the development of regulations on competition and the definition of criteria for selection of the submitted works. The paper also proposes a system of evaluation criteria of electronic educational resources developed by members of the contest organizing committee and jury members. The article emphasizes the importance of not only the preparatory stages of the competition, but also measures for its completion, aimed at training teachers create quality e-learning resources.

  15. X-ray microanalysis of Zn in the taste organ of the teleost Ameiurus nebulosus

    International Nuclear Information System (INIS)

    Reutter, K.

    1983-01-01

    The trace metal Zn seems to be essential for the normal functioning of the gustatory sense. It was tried to localize Zn within the peripheral and central parts of the bullhead's gustatory system by the use of scanning electron microscopy and X-ray microanalysis. In freeze dried preparations of the bullhead's barbel taste buds (and the taste buds of rabbits) Zn is found in randomly distributed granules, which cannot be related to distinct taste bud regions. Furthermore, Zn occurs in subunits of the central gustatory nuclei, the vagal and facial lobe of the rhombencephalon. Therefore Zn appears to be essential for intact peripheral as well as central gustatory processes, at least in lower vertebrates. (author)

  16. Identification of 5'-adenylylimidodiphosphate-hydrolyzing enzyme activity in rabbit taste bud cells using X-ray microanalysis

    International Nuclear Information System (INIS)

    Asanuma, N.

    1990-01-01

    X-ray microanalysis has been used to characterize the enzyme activity hydrolyzing the ATP analogue 5'-adenylylimidodiphosphate (AMP-PNP) in taste bud cells. Rabbit foliate papillae fixed with paraformaldehyde and glutaraldehyde were incubated cytochemically with AMP-PNP as the substrate and lead ion as capture agent. The reaction product which appeared on the microvilli of taste bud cells was examined using an energy dispersive X-ray microanalyzer connected to an analytical electron microscope. The X-ray spectrum thus obtained was compared with that obtained from the product obtained from the demonstration of ATPase activity. Comparison of the phosphorus/lead ratios in the two products showed that twice as much phosphorus was released from an AMP-PNP molecule by the activity in question compared with that released from an ATP molecule by ATPase activity. This indicates that the enzyme hydrolyzes AMP-PNP into AMP and imidodiphosphate and that the enzyme is adenylate cyclase or ATP pyrophosphohydrolase, which possesses a similar hydrolytic property, but not ATPase or alkaline phosphatase, which hydrolyzes AMP-PNP into ADP-NH2 and orthophosphate. This paper provides an example of the use of X-ray microanalysis as a tool for enzyme distinction. The method is applicable to a variety of enzymes and tissues

  17. CHALLENGES OF ELECTRONIC INFORMATION RESOURCES IN ...

    African Journals Online (AJOL)

    This paper discusses the role of policy for proper and efficient library services in the electronic era. It points out some of the possible dangers of embarking in electronic resources without a proper focus at hand. Thus, it calls for today's librarians and policy makers to brainstorm and come up with working policies suitable to ...

  18. Use of Electronic Resources in a Private University in Nigeria ...

    African Journals Online (AJOL)

    The study examined awareness and constraints in the use of electronic resources by lecturers and students of Ajayi Crowther University, Oyo, Nigeria. It aimed at justifying the resources expended in the provision of electronic resources in terms of awareness, patronage and factors that may be affecting awareness and use ...

  19. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-05-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system as potential replacements namely: Proquest 360 Resource Manager, Ex Libris Alma and Open Source CORAL ERMS. After comparing and trialling the systems, it was decided to go for Proquest 360 Resource Manager.

  20. Quality of determinations obtained from laboratory reference samples used in the calibration of X-ray electron probe microanalysis of silicate minerals

    International Nuclear Information System (INIS)

    Pavlova, Ludmila A.; Suvorova, Ludmila F.; Belozerova, Olga Yu.; Pavlov, Sergey M.

    2003-01-01

    Nine simple minerals and oxides, traditionally used as laboratory reference samples in the electron probe microanalysis (EPMA) of silicate minerals, have been quantitatively evaluated. Three separate series of data, comprising the average concentration, standard deviation, relative standard deviation, confidence interval and the z-score of data quality, were calculated for 21 control samples derived from calibrations obtained from three sets of reference samples: (1) simple minerals; (2) oxides; and (3) certified glass reference materials. No systematic difference was observed between the concentrations obtained from these three calibration sets when analyzed results were compared to certified compositions. The relative standard deviations obtained for each element were smaller than target values for all determinations. The z-score values for all elements determined fell within acceptable limits (-2< z<2) for concentrations ranging from 0.1 to 100%. These experiments show that the quality of data obtained from laboratory reference calibration samples is not inferior to that from certified reference glasses. The quality of results obtained corresponds to the 'applied geochemistry' type of analysis (category 2) as defined in the GeoPT proficiency testing program. Therefore, the laboratory reference samples can be used for calibrating EPMA techniques in the analysis of silicate minerals and for controlling the quality of results

  1. use of electronic resources by graduate students of the department

    African Journals Online (AJOL)

    respondent's access electronic resources from the internet via Cybercafé .There is a high ... KEY WORDS: Use, Electronic Resources, Graduate Students, Cybercafé. INTRODUCTION ... Faculty of Education, University of Uyo, Uyo. Olu Olat ...

  2. Electron sputtering in the analytical electron microscope: Calculations and experimental data

    International Nuclear Information System (INIS)

    Zaluzec, N.J.; Mansfield, J.F.

    1987-03-01

    The environment of the electron microscope is particularly severe when one considers the energy deposited in a specimen during typical experimental conditions. Conventional imaging experiments tend to employ electron current densities ranging from ∼0.1 to 1 A/cm 2 while during microanalysis conditions probe current densities can range from 10 to values as high as 10 5 A/cm 2 . At 100 kV this corresponds to power densities from 100 Kilowatts/cm 2 to 10 4 Megawatts/cm 2 . These energy deposition rates can result in electron irradiation damage which can substantially alter the structure and composition of a specimen through either ionization damage in organics or by displacement damage in inorganics and/or combinations thereof. For the most part materials scientists operating an analytical electron microscope (AEM) in the 100 to 200 kV regime studying metallic and/or ceramic specimens have been spared the need to consider either of these effects as their specimens have tended to be sufficiently resilient. However, the advent of the new medium voltage microscopes operating in the 300 to 400 kV regime with high brightness guns and clean or ultrahigh vacuum systems has necessitated a reevaluation of the effects of higher voltage operation in light of the destructive nature of the electron beam particularly under microanalysis conditions

  3. Single-particle characterization of urban aerosol particles collected in three Korean cites using low-Z electron probe X-ray microanalysis.

    Science.gov (United States)

    Ro, Chul-Un; Kim, HyeKyeong; Oh, Keun-Young; Yea, Sun Kyung; Lee, Chong Bum; Jang, Meongdo; Van Grieken, René

    2002-11-15

    A recently developed single-particle analytical technique, called low-Z electron probe X-ray microanalysis (low-Z EPMA), was applied to characterize urban aerosol particles collected in three cities of Korea (Seoul, CheongJu, and ChunCheon) on single days in the winter of 1999. In this study, it is clearly demonstrated that the low-Z EPMA technique can provide detailed and quantitative information on the chemical composition of particles in the urban atmosphere. The collected aerosol particles were analyzed and classified on the basis of their chemical species. Various types of particles were identified, such as soil-derived, carbonaceous, marine-originated, and anthropogenic particles. In the sample collected in Seoul, carbonaceous, aluminosilicates, silicon dioxide, and calcium carbonate aerosol particles were abundantly encountered. In the CheongJu and ChunCheon samples, carbonaceous, aluminosilicates, reacted sea salts, and ammonium sulfate aerosol particles were often seen. However, in the CheongJu sample, ammonium sulfate particles were the most abundant in the fine fraction. Also, calcium sulfate and nitrate particles were significantly observed. In the ChunCheon sample, organic particles were the most abundant in the fine fraction. Also, sodium nitrate particles were seen at high levels. The ChunCheon sample seemed to be strongly influenced by sea-salt aerosols originating from the Yellow Sea, which is located about 115 km away from the city.

  4. Scanning Electron Microscopy and Energy-Dispersive X-Ray Microanalysis of Set CEM Cement after Application of Different Bleaching Agents.

    Science.gov (United States)

    Samiei, Mohammad; Janani, Maryam; Vahdati, Amin; Alemzadeh, Yalda; Bahari, Mahmoud

    2017-01-01

    The present study evaluated the element distribution in completely set calcium-enriched mixture (CEM) cement after application of 35% carbamide peroxide, 40% hydrogen peroxide and sodium perborate as commercial bleaching agents using an energy-dispersive x-ray microanalysis (EDX) system. The surface structure was also observed using the scanning electron microscope (SEM). Twenty completely set CEM cement samples, measuring 4×4 mm 2 , were prepared in the present in vitro study and randomly divided into 4 groups based on the preparation technique as follows: the control group; 35% carbamide peroxide group in contact for 30-60 min for 4 times; 40% hydrogen peroxide group with contact time of 15-20 min for 3 times; and sodium perborate group, where the powder and liquid were mixed and placed on CEM cement surface 4 times. Data were analyzed at a significance level of 0.05 through the one Way ANOVA and Tukey's post hoc tests. EDX showed similar element distribution of oxygen, sodium, calcium and carbon in CEM cement with the use of carbamide peroxide and hydroxide peroxide; however, the distribution of silicon was different ( P structure. Sodium perborate was similar to control group due to its weak oxidizing properties. Globular structures and numerous woodpecker holes were observed on the even surface on the carbamide peroxide group. The mean elemental distribution of completely set CEM cement was different when exposed to sodium perborate, carbamide peroxide and hydrogen peroxide.

  5. Electronic resource management practical perspectives in a new technical services model

    CERN Document Server

    Elguindi, Anne

    2012-01-01

    A significant shift is taking place in libraries, with the purchase of e-resources accounting for the bulk of materials spending. Electronic Resource Management makes the case that technical services workflows need to make a corresponding shift toward e-centric models and highlights the increasing variety of e-formats that are forcing new developments in the field.Six chapters cover key topics, including: technical services models, both past and emerging; staffing and workflow in electronic resource management; implementation and transformation of electronic resource management systems; the ro

  6. Utilization of electronic information resources by academic staff at ...

    African Journals Online (AJOL)

    The study investigated the utilization of Electronic Information resources by the academic staff of Makerere University in Uganda. It examined the academic staff awareness of the resources available, the types of resources provided by the Makerere University Library, the factors affecting resource utilization. The study was ...

  7. Electronic Resources Management Project Presentation 2012

    KAUST Repository

    Ramli, Rindra M.

    2012-01-01

    This presentation describes the electronic resources management project undertaken by the KAUST library. The objectives of this project is to migrate information from MS Sharepoint to Millennium ERM module. One of the advantages of this migration

  8. Practical guide to electronic resources in the humanities

    CERN Document Server

    Dubnjakovic, Ana

    2010-01-01

    From full-text article databases to digitized collections of primary source materials, newly emerging electronic resources have radically impacted how research in the humanities is conducted and discovered. This book, covering high-quality, up-to-date electronic resources for the humanities, is an easy-to-use annotated guide for the librarian, student, and scholar alike. It covers online databases, indexes, archives, and many other critical tools in key humanities disciplines including philosophy, religion, languages and literature, and performing and visual arts. Succinct overviews of key eme

  9. Utilisation of Electronic Information Resources By Lecturers in ...

    African Journals Online (AJOL)

    This study assesses the use of information resources, specifically, electronic databases by lecturers/teachers in Universities and Colleges of Education in South Western Nigeria. Information resources are central to teachers' education. It provides lecturers/teachers access to information that enhances research and ...

  10. Networking strategies of the microscopy community for improved utilization of advanced instruments: (1) The Australian Microscopy and Microanalysis Research Facility (AMMRF)

    International Nuclear Information System (INIS)

    Ringer, S.P.; Apperley, M.H.

    2014-01-01

    This paper describes the strategy underpinning the formation and operation of the Australian Microscopy and Microanalysis Research Facility (AMMRF). AMMRF is a formal collaboration that links eight Australian Universities together to create a user-focused national capability in microscopy and microanalysis. The AMMRF flagship capabilities include: Cameca IMS-1280 and NanoSIMS-50 ion microprobes (University of Western Australia); High-throughput, high-resolution cryoTEM (University of Queensland); Atom Probe Microscopy (University of Sydney); High-resolution Focussed Ion-Beam and SEM (Universities of Adelaide and NSW); High-resolution SEM microanalysis facility (University of New South Wales); and PHI TRIFT V nanoToF ToF-SIMS (University of South Australia). Secondly, a network of peer support and expert training has been established amongst facility professional support staff. The governance and funding of the organisation are described and the advantages and achievements of a nationally coordinated facility for microscopy and microanalysis are set out. Selected data are presented that benchmark the performance of the facility, describe the economic impact and demonstrate the impact on the quality of research outcomes as a result of operating national collaborative research infrastructure for microscopy and microanalysis

  11. Application of X-ray microanalysis to the study of drug uptake in cell culture

    International Nuclear Information System (INIS)

    Reasor, M.J.; Lee, P.; Kirk, R.G.

    1990-01-01

    X-ray microanalysis has been used previously to study the accumulation of iodine in alveolar macrophages of rats treated with the iodinated drug, amiodarone. Due to metabolism of the drug in vivo, primarily to desethylamiodarone, it was not possible to identify the source of the iodine signal. In the present study we have utilized primary cell cultures of alveolar macrophages to study the intracellular accumulation of each of these drug species in vitro. Neither drug is metabolized by these cells in culture, permitting characterization of the accumulation of each independent of the other. Cells were incubated with equimolar concentrations of either amiodarone or desethylamiodarone for 42 hr, and X-ray microanalysis of freeze-dried cryosections of cells was used to quantify accumulation by monitoring the iodine signal associated with each drug. For both drug exposures, the highest iodine content was present in amorphous bodies and dense granules, consistent with the pattern following in vivo exposure. Higher levels of desethylamiodarone, compared to amiodarone, were measured in all compartments of the cells. The results of the in vitro investigation further demonstrate the utility of X-ray microanalysis in the study of the cellular response to amiodarone and desethylamiodarone

  12. Microanalysis of clay-based pigments in paintings by XRD techniques

    Czech Academy of Sciences Publication Activity Database

    Hradil, David; Bezdička, Petr; Hradilová, J.; Vašutová, V.

    2016-01-01

    Roč. 125, MAR (2016), s. 10-20 ISSN 0026-265X R&D Projects: GA ČR(CZ) GA14-22984S Institutional support: RVO:61388980 Keywords : Clay minerals * Earth pigments * Clay-binder interaction * Powder X-ray micro-diffraction * Quantitative phase microanalysis Subject RIV: DB - Geology ; Mineralogy Impact factor: 3.034, year: 2016

  13. Single-particle characterization of 'Asian Dust' certified reference materials using low-Z particle electron probe X-ray microanalysis

    International Nuclear Information System (INIS)

    Hwang, Hee Jin; Ro, Chul-Un

    2006-01-01

    In order to clearly elucidate whether Asian Dust particles experience chemical modification during long-range transport, it is necessary to characterize soil particles where Asian Dust particles originate. If chemical compositions of source soil particles are well characterized, then chemical compositions of Asian Dust particles collected outside source regions can be compared with those of source soil particles in order to find out the occurrence of chemical modification. Asian Dust particles are chemically and morphologically heterogeneous, and thus the average composition and the average aerodynamic diameter (obtainable by bulk analysis) are not much relevant if the chemical modifications of the particles must be followed. The major elemental composition and abundance of the particle types that are potential subjects of chemical modification can only be obtained using single-particle analysis. A single particle analytical technique, named low-Z particle electron probe X-ray microanalysis (low-Z particle EPMA), was applied to characterize two certified reference materials (CRMs) for Asian Dust particles, which were collected from a loess plateau area and a desert of China. The CRMs were defined by bulk analyses to provide certified concentrations for 13 chemical elements. Using the low-Z particle EPMA technique, the concentrations of major chemical species such as aluminosilicates, SiO 2 , CaCO 3 , and carbonaceous species were obtained. Elemental concentrations obtained by the low-Z particle EPMA are close to the certified values, with considering that the single particle and bulk analyses employ very different approaches. There are still some discrepancies between those concentration values, resulting from analyses of particles with different sizes, different sample amounts analyzed, and uncertainties involved in the single particle analysis

  14. Study of the carburization of an austenitic steel through optical and scanning electron microscopy, microhardness and X ray microanalysis of C

    International Nuclear Information System (INIS)

    Champigny, Michel; Gauvain, Danielle; Meny, Lucienne

    1977-01-01

    Carburization tests of 316 L stainless steel have been performed in liquid sodium at 550, 600 and 650 0 C; the depth of penetration of carbon is of the order of 300 μm. The structure of the carburized layer has been studied through optical and scanning electron microscopy: the carbides precipitate first within the grain boundaries, making a nearly continuous superficial carbide layer. The Vickers and Knoop (under 50 g load) microhardness measurements determine the depth of carburization with an error of +-50μm. Though the tensile strength does not vary much with the carburization, the striction, and then the deformation capability, is highly decreased. The variation of the concentration in carbon versus distance has been measured by quantitative X ray microanalysis, using diamond as a standard; the best experimental conditions, regarding the overlapping of the Cr 2 Lα and Ni 3 Lα lines with CK line have been chosen, and the minimum contamination during the measurements has been performed. The results have been confirmed by the analysis of carbon in Fe Ni standards containing less than 1 w/o carbon. The results are discussed with the published data. This work shows that: the increase of microhardness is not related in a simple way with the carbon content of the stainless steel; the carbon concentration can be measured quickly with an error of +-5% when 0,2 [fr

  15. X-Ray Microanalysis of Human Cementum

    Science.gov (United States)

    Alvarez-Pérez, Marco Antonio; Alvarez-Fregoso, Octavio; Ortiz-López, Jaime; Arzate, Higinio

    2005-08-01

    An energy dispersive x-ray microanalysis study was performed throughout the total length of cementum on five impacted human teeth. Mineral content of calcium, phosphorous, and magnesium were determined with an electron probe from the cemento-enamel junction to the root apex on the external surface of the cementum. The concentration profiles for calcium, phosphorous, and magnesium were compared by using Ca/P and Mg/Ca atomic percent ratio. Our findings demonstrated that the Ca/P ratio at the cemento-enamel junction showed the highest values (1.8 2.2). However, the area corresponding to the acellular extrinsic fiber cementum (AEFC) usually located on the coronal one-third of the root surface showed a Ca/P media value of 1.65. Nevertheless, on the area representing the fulcrum of the root there is an abrupt change in the Ca/P ratio, which decreases to 1.3. Our results revealed that Mg2+ distribution throughout the length of human cementum reached its maximum Mg/Ca ratio value of 1.3 1.4 at.% around the fulcrum of the root and an average value of 0.03%. A remarkable finding was that the Mg/Ca ratio pattern distribution showed that in the region where the Ca/P ratio showed a decreasing tendency, the Mg/Ca ratio reached its maximum value, showing a negative correlation. In conclusion, this study has established that clear compositional differences exist between AEFC and cellular mixed stratified cementum varieties and adds new knowledge about Mg2+ distribution and suggests its provocative role regulating human cementum metabolism.

  16. Discipline, availability of electronic resources and the use of Finnish National Electronic Library - FinELib

    Directory of Open Access Journals (Sweden)

    Sanna Torma

    2004-01-01

    Full Text Available This study elaborated relations between digital library use by university faculty, users' discipline and the availability of key resources in the Finnish National Electronic Library (FinELib, Finnish national digital library, by using nationwide representative survey data. The results show that the perceived availability of key electronic resources by researchers in FinELib was a stronger predictor of the frequency and purpose of use of its services than users' discipline. Regardless of discipline a good perceived provision of central resources led to a more frequent use of FinELib. The satisfaction with the services did not vary with the discipline, but with the perceived availability of resources.

  17. Combining trace elements micro-analysis in deposited dredged sediments: EPMA and μ-XRF analysis

    International Nuclear Information System (INIS)

    Poitevin, A; Lerouge, C; Wille, G; Bataillard, P; Quinn, P; Hennet, L

    2012-01-01

    Since deposited dredged sediments are rich in metallic contaminants, they present a risk for environment. This work aims to study dredged sediments chemical composition, identify metal-carrier minerals and understand their mobility. Combining chemical and spectroscopic techniques at multi-scale for an integrative approach of trace elements (zinc, lead, iron) behaviour is therefore necessary. The global mineralogy and the chemistry of the sediment were determined by X-ray diffraction and fluorescence (XRF), respectively. Zn and Pb enriched fractions were separated using a sequential chemical extraction procedure and measured by inductively coupled plasma atomic emission and mass spectroscopy. Microanalyses using scanning electron microscopy (SEM), electron microprobe microanalysis (EPMA), combined with synchrotron radiation X-ray fluorescence (μ-XRF) were carried out to characterize mineralogical phases and identify Zn and Pb carrier minerals. Iron oxyhydroxides and iron sulphides were consistently identify as Zn and Pb carriers. The assumption that carbonate fraction was the major Zn carried phase, as demonstrated by chemical extraction results, was not verified by EPMA or μ-XRF.

  18. The Role of the Acquisitions Librarian in Electronic Resources Management

    Science.gov (United States)

    Pomerantz, Sarah B.

    2010-01-01

    With the ongoing shift to electronic formats for library resources, acquisitions librarians, like the rest of the profession, must adapt to the rapidly changing landscape of electronic resources by keeping up with trends and mastering new skills related to digital publishing, technology, and licensing. The author sought to know what roles…

  19. Quantitative microanalysis with a nuclear microprobe

    International Nuclear Information System (INIS)

    Themner, Klas.

    1989-01-01

    The analytical techniques of paticle induced X-ray emission (PIXE) and Rutherford backscattering (RBS), together with the nuclear microprobe, form a very powerful tool for performing quantitative microanalysis of biological material. Calibration of the X-ray detection system in the microprobe set-up has been performed and the accuracy of the quantitative procedure using RBS for determination of the areal mass density was investigated. The accuracy of the analysis can be affected by alteration in the elemental concentrations during irradiation due to the radiation damage induced by the very intense beams of ionixing radiation. Loss of matrix elements from freeze-dried tissue sections and polymer films have been studied during proton and photon irradiation and the effect on the accuracy discussed. Scanning the beam over an area of the target, with e.g. 32x32 pixels, in order to produce en elemental map, yields a lot of information and, to be able to make an accurate quantitatification, a fast algorithm using descriptions of the different spectral contributions is of need. The production of continuum X-rays by 2.55 MeV protons has been studied and absolute cross-sections for the bremsstrahlung production from thin carbon and some polymer films determined. For the determination of the bremsstrahlung background knowledge of the amounts of the matrix elements is important and a fast program for the evaluation of spectra of proton back- and forward scattering from biological samples has been developed. Quantitative microanalysis with the nuclear microprobe has been performed on brain tissue from rats subjected to different pathological conditions. Increase in calcium levels and decrease in potssium levels for animals subjected to crebral ischaemia and for animals suffering from epileptic seizures were observed coincidentally with or, in some cases before, visible signs of cell necrosis. (author)

  20. Analysis of Pedagogic Potential of Electronic Educational Resources with Elements of Autodidactics

    Directory of Open Access Journals (Sweden)

    Igor A.

    2018-03-01

    Full Text Available Introduction: in recent years didactic properties of electronic educational resources undergo considerable changes, nevertheless, the question of studying of such complete phenomenon as “an electronic educational resource with autodidactics elements” remains open, despite sufficient scientific base of researches of the terms making this concept. Article purpose – determination of essence of electronic educational resources with autodidactics elements. Materials and Methods: the main method of research was the theoretical analysis of the pedagogical and psychological literature on the problem under study. We used the theoretical (analysis, synthesis, comparison and generalization methods, the method of interpretation, pedagogical modeling, and empirical methods (observation, testing, conversation, interview, analysis of students’ performance, pedagogical experiment, peer review. Results: we detected the advantages of electronic educational resources in comparison with traditional ones. The concept of autodidactics as applied to the subject of research is considered. Properties of electronic educational resources with a linear and nonlinear principle of construction are studied.The influence of the principle of construction on the development of the learners’ qualities is shown. We formulated an integral definition of electronic educational resources with elements of autodidactics, namely, the variability, adaptivity and cyclicity of training. A model of the teaching-learning process with electronic educational resources is developed. Discussion and Conclusions: further development of a problem will allow to define whether electronic educational resources with autodidactics elements pedagogical potential for realization of educational and self-educational activity of teachers have, to modify technological procedures taking into account age features of students, their specialties and features of the organization of process of training of

  1. Preservation and conservation of electronic information resources of ...

    African Journals Online (AJOL)

    The major holdings of the broadcast libraries of the Nigerian Television Authority (NTA) are electronic information resources; therefore, providing safe places for general management of these resources have aroused interest in the industry in Nigeria for sometimes. The need to study the preservation and conservation of ...

  2. Building an electronic resource collection a practical guide

    CERN Document Server

    Lee, Stuart D

    2004-01-01

    This practical book guides information professionals step-by-step through building and managing an electronic resource collection. It outlines the range of electronic products currently available in abstracting and indexing, bibliographic, and other services and then describes how to effectively select, evaluate and purchase them.

  3. Analysis of Human Resources Management Strategy in China Electronic Commerce Enterprises

    Science.gov (United States)

    Shao, Fang

    The paper discussed electronic-commerce's influence on enterprise human resources management, proposed and proved the human resources management strategy which electronic commerce enterprise should adopt from recruitment strategy to training strategy, keeping talent strategy and other ways.

  4. Using XML Technologies to Organize Electronic Reference Resources

    OpenAIRE

    Huser, Vojtech; Del Fiol, Guilherme; Rocha, Roberto A.

    2005-01-01

    Provision of access to reference electronic resources to clinicians is becoming increasingly important. We have created a framework for librarians to manage access to these resources at an enterprise level, rather than at the individual hospital libraries. We describe initial project requirements, implementation details, and some preliminary results.

  5. Statistics techniques applied to electron probe microanalysis

    International Nuclear Information System (INIS)

    Brizuela, H.; Del Giorgio, M.; Budde, C.; Briozzo, C.; Riveros, J.

    1987-01-01

    A description of Montroll-West's general theory for a tridimensional random walk of a particle with internal degrees of freedom is given, connecting this problem with the master equation solution. The possibility of its application to EPMA is discussed. Numerical solutions are given for thick or collimated beams at several energies interacting with samples of different shape and size. Spatial distribution of particles within the sample -for a stationary state- is analized, as well as the electron backscattering coefficient. (Author) [es

  6. Source Apportionment of Atmospheric Particles by Electron Probe X-Ray Microanalysis and Receptor Models.

    Science.gov (United States)

    van Borm, Werner August

    Electron probe X-ray microanalysis (EPXMA) in combination with an automation system and an energy-dispersive X-ray detection system was used to analyse thousands of microscopical particles, originating from the ambient atmosphere. The huge amount of data was processed by a newly developed X-ray correction method and a number of data reduction procedures. A standardless ZAF procedure for EPXMA was developed for quick semi-quantitative analysis of particles starting from simple corrections, valid for bulk samples and modified taking into account the particle finit diameter, assuming a spherical shape. Tested on a limited database of bulk and particulate samples, the compromise between calculation speed and accuracy yielded for elements with Z > 14 accuracies on concentrations less than 10% while absolute deviations remained below 4 weight%, thus being only important for low concentrations. Next, the possibilities for the use of supervised and unsupervised multivariate particle classification were investigated for source apportionment of individual particles. In a detailed study of the unsupervised cluster analysis technique several aspects were considered, that have a severe influence on the final cluster analysis results, i.e. data acquisition, X-ray peak identification, data normalization, scaling, variable selection, similarity measure, cluster strategy, cluster significance and error propagation. A supervised approach was developed using an expert system-like approach in which identification rules are builded to describe the particle classes in a unique manner. Applications are presented for particles sampled (1) near a zinc smelter (Vieille-Montagne, Balen, Belgium), analyzed for heavy metals, (2) in an urban aerosol (Antwerp, Belgium), analyzed for over 20 elements and (3) in a rural aerosol originating from a swiss mountain area (Bern). Thus is was possible to pinpoint a number of known and unknown sources and characterize their emissions in terms of particles

  7. Electronic Resources and Mission Creep: Reorganizing the Library for the Twenty-First Century

    Science.gov (United States)

    Stachokas, George

    2009-01-01

    The position of electronic resources librarian was created to serve as a specialist in the negotiation of license agreements for electronic resources, but mission creep has added more functions to the routine work of electronic resources such as cataloging, gathering information for collection development, and technical support. As electronic…

  8. The method of quantitative X-ray microanalysis of fine inclusions in copper

    International Nuclear Information System (INIS)

    Morawiec, H.; Kubica, L.; Piszczek, J.

    1978-01-01

    The method of correction for the matrix effect in quantitative x-ray microanalysis was presented. The application of the method was discussed on the example of quantitative analysis of fine inclusions of Cu 2 S and Cu 2 O in copper. (author)

  9. Low temperature x-ray microanalysis of highly mineralised biological samples

    International Nuclear Information System (INIS)

    Clode, P.L.; Marshall, A.T.

    2002-01-01

    Full text: Scleractinian corals are highly calcified animals that possess a massive CaCO 3 skeleton, which is associated with a thin, two-layered epithelium. The presence of the skeleton often precludes the use of conventional techniques for examination of the tissue by light and electron microscopy and necessitates an innovative approach to specimen preparation and analysis. Using a preparatory technique devised by the current authors (Clode and Marshall, 2001), we have applied low temperature x-ray microanalysis to frozen-hydrated preparations of the highly mineralised scleractinian coral Galaxea fascicularis. This has allowed us to identify sites of Ca accumulation and to suggest possible modes of Ca movement across the tissue prior to deposition within the skeleton. Mucocytes, seawater (SW) zones, symbiotic algae (zooxanthellae) and lipid were all found to contain high concentrations of Ca. A significant Ca gradient that increased inwardly, from the oral ectoderm toward the skeleton, was evident within each of these features except lipid. This data suggests that Ca uptake and accumulation occurs via an active, transcellular route. The presence of high S, K and Ca concentrations in the SW immediately adjacent to the external surface of the polyp is indicative of a mucous layer creating a Donnan matrix. This matrix may facilitate Ca uptake from the surrounding SW into the tissue, and is also likely to selectively influence diffusional properties at the SW - oral ectodermal interface. Copyright (2002) Australian Society for Electron Microscopy Inc

  10. A simple method to improve the quantification accuracy of energy-dispersive X-ray microanalysis

    International Nuclear Information System (INIS)

    Walther, T

    2008-01-01

    Energy-dispersive X-ray spectroscopy in a transmission electron microscope is a standard tool for chemical microanalysis and routinely provides qualitative information on the presence of all major elements above Z=5 (boron) in a sample. Spectrum quantification relies on suitable corrections for absorption and fluorescence, in particular for thick samples and soft X-rays. A brief presentation is given of an easy way to improve quantification accuracy by evaluating the intensity ratio of two measurements acquired at different detector take-off angles. As the take-off angle determines the effective sample thickness seen by the detector this method corresponds to taking two measurements from the same position at two different thicknesses, which allows to correct absorption and fluorescence more reliably. An analytical solution for determining the depth of a feature embedded in the specimen foil is also provided.

  11. Contribution to the application of nuclear microprobe in geochemistry. Carbon and nitrogen microanalysis in glasses and minerals

    International Nuclear Information System (INIS)

    Mosbah, M.

    1988-01-01

    The morphological complexity of geological materials implies the use of microanalysis techniques utilization. Nuclear microprobe allows selective and no destructive light elements determination, through nuclear reactions. Nuclear microanalysis has been used to characterize carbon and nitrogen in volatile phase dissolved in magmatic samples. The application of some microanalysis techniques in geochemistry are discussed, nuclear microprobe theory and techniques are developed. Minerals, glasses and glassy inclusions are described, and more particularly, the interest of these investigations. Optimal conditions of carbon and nitrogen analysis ( 12 C(d.p) 13 C and 14 N(d,p) 15 N reaction respectively), as deuteron energy and observation angle are studied. A methodology has been established for this purpose. Several results are exposed: Punctual analysis, carbon concentration profile in depth surface scanning, surficial mapping in glassy inclusions. The carbon content interpretation in glassy inclusions measured conveniently for the first time agrees with data obtained through other techniques. In conclusion, degazing schedule improvements require more analysis. Perspective research axis are evocated [fr

  12. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system

  13. Iron speciation of airborne subway particles by the combined use of energy dispersive electron probe X-ray microanalysis and Raman microspectrometry.

    Science.gov (United States)

    Eom, Hyo-Jin; Jung, Hae-Jin; Sobanska, Sophie; Chung, Sang-Gwi; Son, Youn-Suk; Kim, Jo-Chun; Sunwoo, Young; Ro, Chul-Un

    2013-11-05

    Quantitative energy-dispersive electron probe X-ray microanalysis (ED-EPMA), known as low-Z particle EPMA, and Raman microspectrometry (RMS) were applied in combination for an analysis of the iron species in airborne PM10 particles collected in underground subway tunnels. Iron species have been reported to be a major chemical species in underground subway particles generated mainly from mechanical wear and friction processes. In particular, iron-containing particles in subway tunnels are expected to be generated with minimal outdoor influence on the particle composition. Because iron-containing particles have different toxicity and magnetic properties depending on their oxidation states, it is important to determine the iron species of underground subway particles in the context of both indoor public health and control measures. A recently developed analytical methodology, i.e., the combined use of low-Z particle EPMA and RMS, was used to identify the chemical species of the same individual subway particles on a single particle basis, and the bulk iron compositions of airborne subway particles were also analyzed by X-ray diffraction. The majority of airborne subway particles collected in the underground tunnels were found to be magnetite, hematite, and iron metal. All the particles collected in the tunnels of underground subway stations were attracted to permanent magnets due mainly to the almost ubiquitous ferrimagnetic magnetite, indicating that airborne subway particles can be removed using magnets as a control measure.

  14. Cytochemical and x-ray microanalysis studies of intracellular calcium pools in scale-bearing cells of the coccolithophorid emiliana huxleyi

    International Nuclear Information System (INIS)

    Wal, P. van der; Bruijn, W.C. de; Westbroek, P.

    1985-01-01

    Emiliania huxleyi is a coccolithophorid with a life cycle including a stage characterized by the occurrence of a scale-bearing cell type. The scales are composed of organic material and are produced in the cisternae of the Golgi apparatus. The present report deals with the ultrastructural calcium localization in scale-bearing cells using cation-precipitating agents. Cations were precipitated either with potassium carbonate, or potassium phosphate, and then with potassium pyroantimonate. The distribution of electron-opaque deposits was the same when visualized by all four techniques. The most extensive deposits occurred in the Golgi apparatus, the 'peripheral space' (a cellular compartment totally encompassing the protoplast), the multivesicular bodies, and the cell vacuole. X-ray microanalysis revealed that calcium was a constituent of the electron-opaque deposits. The uptake and transport of calcium, as universal functions of the Golgi apparatus, are discussed. (Author)

  15. The Internet School of Medicine: use of electronic resources by medical trainees and the reliability of those resources.

    Science.gov (United States)

    Egle, Jonathan P; Smeenge, David M; Kassem, Kamal M; Mittal, Vijay K

    2015-01-01

    Electronic sources of medical information are plentiful, and numerous studies have demonstrated the use of the Internet by patients and the variable reliability of these sources. Studies have investigated neither the use of web-based resources by residents, nor the reliability of the information available on these websites. A web-based survey was distributed to surgical residents in Michigan and third- and fourth-year medical students at an American allopathic and osteopathic medical school and a Caribbean allopathic school regarding their preferred sources of medical information in various situations. A set of 254 queries simulating those faced by medical trainees on rounds, on a written examination, or during patient care was developed. The top 5 electronic resources cited by the trainees were evaluated for their ability to answer these questions accurately, using standard textbooks as the point of reference. The respondents reported a wide variety of overall preferred resources. Most of the 73 responding medical trainees favored textbooks or board review books for prolonged studying, but electronic resources are frequently used for quick studying, clinical decision-making questions, and medication queries. The most commonly used electronic resources were UpToDate, Google, Medscape, Wikipedia, and Epocrates. UpToDate and Epocrates had the highest percentage of correct answers (47%) and Wikipedia had the lowest (26%). Epocrates also had the highest percentage of wrong answers (30%), whereas Google had the lowest percentage (18%). All resources had a significant number of questions that they were unable to answer. Though hardcopy books have not been completely replaced by electronic resources, more than half of medical students and nearly half of residents prefer web-based sources of information. For quick questions and studying, both groups prefer Internet sources. However, the most commonly used electronic resources fail to answer clinical queries more than half

  16. Energy dispersive X-ray microanalysis of zinc and calcium in organelles of insulin-producing cells of the mouse, rat, and a fish

    Energy Technology Data Exchange (ETDEWEB)

    Falkmer, S; Odselius, R [Lund Univ. (Sweden); Blondel, B; Prentki, M; Wollheim, C B [Geneva Univ. (Switzerland)

    1985-01-01

    By means of energy dispersive X-ray microanalysis in the scanning-transmission electron microscope, spectra were obtained from quick-frozen, cryo-ultramicrotome-cut, freeze-dried sections of insulin cells from a fish and a mouse. It was shown that both zinc and calcium are present in significant quantities in native islet cell ..beta.. granules. In the ..beta.. granules of the rat RINm5F insuloma cells calcium, but not zinc, seemed to accumulate; the zinc contents in the secretion granules of these neoplastic ..beta.. cells were probably below the detection limit.

  17. Preparation of biological samples for transmission X-ray microanalysis: a review of alternative procedures to the use of sectioned material

    International Nuclear Information System (INIS)

    Sigee, D.C.

    1988-01-01

    Although transmission X-ray microanalysis of biological material has traditionally been carried out mainly on sectioned preparations, a number of alternative procedures exist. These are considered under three major headings - whole cell preparations, analysis of cell homogenates and biological fluids, and applications of the technique to microsamples of purified biochemicals. These three aspects provide a continuous range of investigative level - from the cellular to the molecular. The use of X-ray microanalysis with whole cell preparations is considered in reference to eukaryote (animal) cells and prokaryotes - where it has particular potential in environmental studies on bacteria. In the case of cell homogenates and biological fluids, the technique has been used mainly with microdroplets of animal material. The use of X-ray microanalysis with purified biochemicals is considered in relation to both particulate and non-particulate samples. In the latter category, the application of this technique for analysis of thin films of metalloprotein is particularly emphasised. It is concluded that wider use could be made of the range of preparative techniques available - both within a particular investigation, and in diverse fields of study. Transmission X-ray microanalysis has implications for environmental, physiological and molecular biology as well as cell biology

  18. Elemental microanalysis of biological and medical specimens with a scanning proton microprobe

    International Nuclear Information System (INIS)

    Legge, G.J.F.; Mazzolini, A.P.

    1979-01-01

    The scanning proton microprobe is shown to be a sensitive instrument for elemental microanalysis of cells and tissues in biological and medical specimens. The preparation of specimens and their behaviour under irradiation are crucial and the application of quantitative scanning analysis to the monitoring of such problems is illustrated

  19. ANALYTICAL REVIEW OF ELECTRONIC RESOURCES FOR THE STUDY OF LATIN

    Directory of Open Access Journals (Sweden)

    Olena Yu. Balalaieva

    2014-04-01

    Full Text Available The article investigates the current state of development of e-learning content in the Latin language. It is noted that the introduction of ICT in the educational space has expanded the possibility of studying Latin, opened access to digital libraries resources, made it possible to use scientific and educational potential and teaching Latin best practices of world's leading universities. A review of foreign and Ukrainian information resources and electronic editions for the study of Latin is given. Much attention was paid to the didactic potential of local and online multimedia courses of Latin, electronic textbooks, workbooks of interactive tests and exercises, various dictionaries and software translators, databases and digital libraries. Based on analysis of the world market of educational services and products the main trends in the development of information resources and electronic books are examined. It was found that multimedia courses with interactive exercises or workbooks with interactive tests, online dictionaries and translators are the most widely represented and demanded. The noticeable lagging of Ukrainian education and computer linguistics in quantitative and qualitative measures in this industry is established. The obvious drawback of existing Ukrainian resources and electronic editions for the study of Latin is their noninteractive nature. The prospects of e-learning content in Latin in Ukraine are outlined.

  20. Elektronik Bilgi Kaynaklarının Seçimi / Selection of Electronic Information Resources

    Directory of Open Access Journals (Sweden)

    Pınar Al

    2003-04-01

    Full Text Available For many years, library users have used only from the printed media in order to get the information that they have needed. Today with the widespread use of the Web and the addition of electronic information resources to library collections, the use of information in the electronic environment as well as in printed media is started to be used. In time, such types of information resources as, electronic journals, electronic books, electronic encyclopedias, electronic dictionaries and electronic theses have been added to library collections. In this study, selection criteria that can be used for electronic information resources are discussed and suggestions are provided for libraries that try to select electronic information resources for their collections.

  1. Atom probe microanalysis: Principles and applications to materials problems

    International Nuclear Information System (INIS)

    Miller, M.K.; Smith, G.D.W.

    1987-01-01

    A historical background and general introduction to field emission and field-ionization, field-ion microscopy, and the atom probe is given. Physical principles of field ion microscopy are explained, followed by interpretation of images. Types of atom probes are discussed, as well as the instrumentation used in atomic probe microanalysis. Methods of atom probe analysis and data representation are covered, along with factors affecting performance and statistical analysis of atom probe data. Finally, some case studies and special types of analyses are presented

  2. Nuclear microanalysis of oxide films on structural steel

    International Nuclear Information System (INIS)

    Istomin, I.V.; Karabash, V.A.; Maisyukov, V.D.; Sosnin, A.N.; Shorin, V.S.

    1989-01-01

    Studies of the behavior of structural materials in nuclear power plants have indicated the important role of oxide films on metals, especially metals of the iron group. The films may be formed as a result of the corrosion of the metal in an aggressive coolant. At the same time, some oxide films have anticorrosive properties and can be produced specially by the introduction of inhibitor-passivators, e.g., molecular oxygen, into the aggressive medium. Experimental data on the film growth rate make it possible to determine the kinetics of the oxidation process, the nature of the diffusion of the main components through the film, and the role of the phase transitions (crystal-chemical transformations) and point defects during the migration of oxygen and metal ions through the oxide. In this study nuclear microanalysis is used to measure the parameters of oxide films formed on 10Cr2Mo and 1Cr18Ni10Ti steels in steam in the temperature range 320-620C. In this method the film parameters in the general analysis of the energy spectra of deuterons back-scattered from iron nuclei and protons in the case of the 16 O(d,p 1 ) 17 O nuclear reaction. With this approach and an initial deuteron energy E o = 0.9 MeV the range of the measurable thickness t of the films is 0.001-1.5 mg/cm 2 . The data obtained not only confirm the high sensitivity of the nuclear microanalysis method but also demonstrate that it can be used for nondestructive quality control of the surface

  3. Access to electronic resources by visually impaired people

    Directory of Open Access Journals (Sweden)

    Jenny Craven

    2003-01-01

    Full Text Available Research into access to electronic resources by visually impaired people undertaken by the Centre for Research in Library and Information Management has not only explored the accessibility of websites and levels of awareness in providing websites that adhere to design for all principles, but has sought to enhance understanding of information seeking behaviour of blind and visually impaired people when using digital resources.

  4. Choice and preparation of standard samples for X-ray spectral microanalysis

    International Nuclear Information System (INIS)

    Gavrilenko, I.S.; Surzhko, V.F.

    1989-01-01

    Choice, preparation and certification of standard samples for X-ray spectral microanalysis are considered. Requirements for standard samples in terms of concentration and volume, porosity, corrosion, conductivity distribution are formulated. Stages of sample preparation process, including composition choice, heat treatment, section production, certification, are considered in detail. The choice of composition is based on studying phase equilibrium diagrams, subdivided into 6 types

  5. Library training to promote electronic resource usage

    DEFF Research Database (Denmark)

    Frandsen, Tove Faber; Tibyampansha, Dativa; Ibrahim, Glory

    2017-01-01

    Purpose: Increasing the usage of electronic resources is an issue of concern for many libraries all over the world. Several studies stress the importance of information literacy and instruction in order to increase the usage. Design/methodology/approach: The present article presents the results...

  6. Why and How to Measure the Use of Electronic Resources

    Directory of Open Access Journals (Sweden)

    Jean Bernon

    2008-11-01

    Full Text Available A complete overview of library activity implies a complete and reliable measurement of the use of both electronic resources and printed materials. This measurement is based on three sets of definitions: document types, use types and user types. There is a common model of definitions for printed materials, but a lot of questions and technical issues remain for electronic resources. In 2006 a French national working group studied these questions. It relied on the COUNTER standard, but found it insufficient and pointed out the need for local tools such as web markers and deep analysis of proxy logs. Within the French national consortium COUPERIN, a new working group is testing ERMS, SUSHI standards, Shibboleth authentication, along with COUNTER standards, to improve the counting of the electronic resources use. At this stage this counting is insufficient and its improvement will be a European challenge for the future.

  7. Impacts on the Hubble Space Telescope Wide Field and Planetary Camera 2: Microanalysis and Recognition of Micrometeoroid Compositions

    Science.gov (United States)

    Kearsley, A. T.; Ross, D. K.; Anz-Meador, P.; Liou, J. C.; Opiela, J.; Grime, G. W.; Webb, R. P.; Jeynes, C.; Palitsin, V. V.; Colaux, J. L.; hide

    2014-01-01

    Postflight surveys of the Wide Field and Planetary Camera 2 (WFPC2) on the Hubble Space Telescope have located hundreds of features on the 2.2 by 0.8 m curved plate, evidence of hypervelocity impact by small particles during 16 years of exposure to space in low Earth orbit (LEO). The radiator has a 100 - 200 micron surface layer of white paint, overlying 4 mm thick Al alloy, which was not fully penetrated by any impact. Over 460 WFPC2 samples were extracted by coring at JSC. About half were sent to NHM in a collaborative program with NASA, ESA and IBC. The structural and compositional heterogeneity at micrometer scale required microanalysis by electron and ion beam microscopes to determine the nature of the impactors (artificial orbital debris, or natural micrometeoroids, MM). Examples of MM impacts are described elsewhere. Here we describe the development of novel electron beam analysis protocols, required to recognize the subtle traces of MM residues.

  8. Multi-dimensional microanalysis of masklessly implanted atoms using focused heavy ion beam

    International Nuclear Information System (INIS)

    Mokuno, Yoshiaki; Iiorino, Yuji; Chayahara, Akiyoshi; Kiuchi, Masato; Fujii, Kanenaga; Satou, Mamoru

    1992-01-01

    Multi-dimensional structure fabricated by maskless MeV gold implantation in silicon wafer was analyzed by 3 MeV carbon ion microprobe using a microbeam line developed at GIRIO. The minimum line width of the implanted region was estimated to be about 5 μm. The advantages of heavy ions for microanalysis were demonstrated. (author)

  9. Prepare of microanalysis reference material for nuclear analysis of Chinese ancient ceramic

    International Nuclear Information System (INIS)

    Feng Songlin; Xu Qing; Feng Xiangqian; Fan Dongyu; Lei Yong; Cheng Lin

    2005-01-01

    Some analytic technique can play important role for identifying the provenance and age of ceramic ware. However, it is usually not allowed to destructive analyze for a valuable intact porcelain ware. These analysis methods such as X-ray Fluorescence (XRF), Proton Induced X-ray Emission (PIXE), and Synchrotron Radiation X-ray Fluorescence (SRXRF) are suitable for nondestructive analysis of ancient ceramic wares. In order to compare the analytic data obtained by different measuring method and identify the provenance and age accurately, the effective way is to calibrate elemental concentration in body and glaze of ceramic ware. Microanalysis reference material (MRM) of ancient ceramic has to be prepared for achieving quantitative analysis. A solid powder 99% in size of 500 mesh for microanalysis reference material (MRM) has being prepared in institute of high energy physics. The minimum analytic masses of 1 mg were determined by Neutron Activation Analysis (NAA) for these elements (Sc, Cr, Co, Rb: Cs, La, Ce, Nd, Sm, Tb, Yb, Lu; Hf, Ta, Th, U), and by SRXRF for elements (K, Ca, Ti, Mn, Fe, Zn; Rb, Sr).

  10. Euler European Libraries and Electronic Resources in Mathematical Sciences

    CERN Document Server

    The Euler Project. Karlsruhe

    The European Libraries and Electronic Resources (EULER) Project in Mathematical Sciences provides the EulerService site for searching out "mathematical resources such as books, pre-prints, web-pages, abstracts, proceedings, serials, technical reports preprints) and NetLab (for Internet resources), this outstanding engine is capable of simple, full, and refined searches. It also offers a browse option, which responds to entries in the author, keyword, and title fields. Further information about the Project is provided at the EULER homepage.

  11. Effects of Electronic Information Resources Skills Training for Lecturers on Pedagogical Practices and Research Productivity

    Science.gov (United States)

    Bhukuvhani, Crispen; Chiparausha, Blessing; Zuvalinyenga, Dorcas

    2012-01-01

    Lecturers use various electronic resources at different frequencies. The university library's information literacy skills workshops and seminars are the main sources of knowledge of accessing electronic resources. The use of electronic resources can be said to have positively affected lecturers' pedagogical practices and their work in general. The…

  12. Microanalysis of clay-based pigments in painted artworks by the means of Raman spectroscopy

    Czech Academy of Sciences Publication Activity Database

    Košařová, V.; Hradil, David; Němec, I.; Bezdička, Petr; Kanický, V.

    2013-01-01

    Roč. 44, č. 11 (2013), s. 1570-1577 ISSN 0377-0486 Institutional support: RVO:61388980 Keywords : Raman spectroscopy * clay-based pigments * clay minerals * iron oxides * microanalysis of paintings Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.519, year: 2013

  13. A flexible and accurate quantification algorithm for electron probe X-ray microanalysis based on thin-film element yields

    International Nuclear Information System (INIS)

    Schalm, O.; Janssens, K.

    2003-01-01

    Quantitative analysis by means of electron probe X-ray microanalysis (EPXMA) of low Z materials such as silicate glasses can be hampered by the fact that ice or other contaminants build up on the Si(Li) detector beryllium window or (in the case of a windowless detector) on the Si(Li) crystal itself. These layers act as an additional absorber in front of the detector crystal, decreasing the detection efficiency at low energies (<5 keV). Since the layer thickness gradually changes with time, also the detector efficiency in the low energy region is not constant. Using the normal ZAF approach to quantification of EPXMA data is cumbersome in these conditions, because spectra from reference materials and from unknown samples must be acquired within a fairly short period of time in order to avoid the effect of the change in efficiency. To avoid this problem, an alternative approach to quantification of EPXMA data is proposed, following a philosophy often employed in quantitative analysis of X-ray fluorescence (XRF) and proton-induced X-ray emission (PIXE) data. This approach is based on the (experimental) determination of thin-film element yields, rather than starting from infinitely thick and single element calibration standards. These thin-film sensitivity coefficients can also be interpolated to allow quantification of elements for which no suitable standards are available. The change in detector efficiency can be monitored by collecting an X-ray spectrum of one multi-element glass standard. This information is used to adapt the previously determined thin-film sensitivity coefficients to the actual detector efficiency conditions valid on the day that the experiments were carried out. The main advantage of this method is that spectra collected from the standards and from the unknown samples should not be acquired within a short period of time. This new approach is evaluated for glass and metal matrices and is compared with a standard ZAF method

  14. Electronic Commerce Resource Centers. An Industry--University Partnership.

    Science.gov (United States)

    Gulledge, Thomas R.; Sommer, Rainer; Tarimcilar, M. Murat

    1999-01-01

    Electronic Commerce Resource Centers focus on transferring emerging technologies to small businesses through university/industry partnerships. Successful implementation hinges on a strategic operating plan, creation of measurable value for customers, investment in customer-targeted training, and measurement of performance outputs. (SK)

  15. Coherence in electron energy loss spectrometry

    International Nuclear Information System (INIS)

    Schattschneider, P.; Werner, W.S.M.

    2005-01-01

    Coherence effects in electron energy loss spectrometry (EELS) and in energy filtering are largely neglected although they occur frequently due to Bragg scattering in crystals. We discuss how coherence in the inelastically scattered wave field can be described by the mixed dynamic form factor (MDFF), and how it relates to the density matrix of the scattered electrons. Among the many aspects of 'inelastic coherence' are filtered high-resolution images, dipole-forbidden transitions, coherence in plasma excitations, errors in chemical microanalysis, coherent double plasmons, and circular dichroism

  16. Energy dispersive X-ray analysis in the electron microscope

    CERN Document Server

    Bell, DC

    2003-01-01

    This book provides an in-depth description of x-ray microanalysis in the electron microscope. It is sufficiently detailed to ensure that novices will understand the nuances of high-quality EDX analysis. Includes information about hardware design as well as the physics of x-ray generation, absorption and detection, and most post-detection data processing. Details on electron optics and electron probe formation allow the novice to make sensible adjustments to the electron microscope in order to set up a system which optimises analysis. It also helps the reader determine which microanalytical me

  17. Practical applications of energy dispersive X-ray microanalysis in diagnostic oral pathology

    International Nuclear Information System (INIS)

    Daley, T.D.; Gibson, D.

    1990-01-01

    Energy dispersive X-ray microanalysis is a powerful tool that can reveal the presence and relative quantities of elements in minute particles in biologic materials. Although this technique has been used in some aspects of dental research, it has rarely been applied to diagnostic oral pathology. The purpose of this paper is to inform practicing dentists and oral specialists about the diagnostic potential of this procedure by presenting three case reports. The first case involved the identification of flakes of a metallic material claimed by a 14-year-old girl to appear periodically between her mandibular molars. In the second case, a periodontist was spared a lawsuit when a freely mobile mass in the antrum of his patient was found to be a calcium-phosphorus compound not related to the periodontal packing that had been used. The third case involved the differential diagnosis of amalgam tattoo and graphite tattoo in a pigmented lesion of the hard palate mucosa. The results of the analyses were significant and indicate a role for this technique in the assessment of selected cases. Potential for wider use of energy dispersive X-ray microanalysis in diagnostic oral pathology exists as research progresses

  18. Microanalysis of oligosaccharide HS203 in beagle dog plasma by postcolumn fluorescence derivatization method.

    Science.gov (United States)

    Sun, Shumeng; Zhao, Xia; Li, Guangsheng; Yu, Guangli; Xing, Xiaoxu; Zeng, Yangyang; Wu, Jian; Wang, Jianing

    2012-06-20

    A rapid and sensitive postcolumn fluorescence derivatization method was developed for microanalysis of antidiabetic oligosaccharide HS203 in beagle dog plasma. After plasma protein was removed by a simple and fast ultrafiltration method, chromatographic separation was performed on an Asahipak GS-320 HQ column with a mobile phase of 50 mmol/L phosphate buffer (pH 6.7) and acetonitrile (83/17, v/v). The column effluent was monitored by fluorescence detection at 249 nm (excitation) and 435 nm (emission) using guanidine hydrochloride as a postcolumn derivatizing reagent. A satisfactory resolution of the analyte was achieved and the limit of detection was found to be 4 ng (more sensitive than silver staining of HS203 in polyacrylamide gel electrophoresis). The method described above was successfully applied to a pharmacokinetic study of HS203 and to monitor blood glucose level simultaneously in beagle dog. It is also possible to be applied for microanalysis of other oligosaccharides in biological samples. Copyright © 2012 Elsevier Ltd. All rights reserved.

  19. A Fuel Microanalysis for a Deep Burn-High Temperature Reactor

    International Nuclear Information System (INIS)

    Kim, Young Min; Jo, Chang Keun; Jun, Ji Su; Cho, Moon Sung

    2010-08-01

    The microanalysis for a deep burn-high temperature reactor (DB-HTR) covers the gas pressure buildup in a coated fuel particle (CFP), the thermo-mechanical behavior of a CFP, the failure probabilities of CFPs, the thermal analysis for a fuel element and a CFP, and the fission product transport into a coolant. The fuel performance analysis code of KAERI, COPA, is used in the microanalysis. The considered fuel materials are 0.2% UO 2 + 99.8% (5% NpO 2 + 95% PuO 1.8 ) mixed with 0.6 moles of silicon carbide (SiC) per mole of heavy metal and 30% UO 2 + 70% (5% NpO 2 + 95% PuO 1.8 ) mixed with 0.6 moles SiC per mole of heavy metal. Two thermal powers, 600 and 450 MW th , are taken into account. It was assumed that the DB-HTR was operated at constant temperature and power for normal operation and then was subjected to a low pressure conduction cooling (LPCC) accident for 250 hours. All the fuels of the DB-HTRs had good mechanical and thermal integrity during normal operation. But in the LPCC accident, whole particle failure occurred in the 600 MW DB-HTRs and the failure fractions in the 450 MW DB-HTRs are below 0.03. In order to secure the integrity of CFPs during the LPCC accident, it is necessary to reduce the excessive temperatures and the gas pressure in a CFP

  20. Secondary mineralization in carious lesions of human dentin. Electron-probe, electron microscope, and electron diffraction studies

    Energy Technology Data Exchange (ETDEWEB)

    Ogiwara, H [Tokyo Dental Coll. (Japan)

    1975-02-01

    Dentinal carious lesions having a remineralized surface layer were studied by means electron-probe microanalysis, electron microscopy, electron diffraction. As the results of electron-probe study, F, Mg, and Na were found to be distributed mainly in the remineralized surface layer and S in the decalcified region where decreases in Ca, P, and Mg concentration were usually observed. The decrease in Mg concentration always started earlier than that of Ca and P concentration. Electron microscope and electron diffraction studies revealed that apatic crystals in the remineralized surface layer were much larger than those in the intact dentin. Although they were less conspicuous, crystals in the decalcified region also were larger than those in the intact region. Dentinal tubules, occluded by many crystals, were frequently seen during the observations. Crystals in the tubules varied in morphology, showing granular, needle, rhomboid, and tabular shapes. By means of electron diffraction, the granular- or needle-shaped crystals were identified as apatite and the rhomboid-shaped crystals as whitlockite. Some of the tabular-shaped crystals appeared to be cotacalcium phosphate.

  1. The MicroAnalysis Toolkit: X-ray Fluorescence Image Processing Software

    International Nuclear Information System (INIS)

    Webb, S. M.

    2011-01-01

    The MicroAnalysis Toolkit is an analysis suite designed for the processing of x-ray fluorescence microprobe data. The program contains a wide variety of analysis tools, including image maps, correlation plots, simple image math, image filtering, multiple energy image fitting, semi-quantitative elemental analysis, x-ray fluorescence spectrum analysis, principle component analysis, and tomographic reconstructions. To be as widely useful as possible, data formats from many synchrotron sources can be read by the program with more formats available by request. An overview of the most common features will be presented.

  2. Limitations of ZAF correction factors in the determination of calcium/phosphorus ratios: Important forensic science considerations relevant to the analysis of bone fragments using scanning electron microscopy and energy-dispersive x-ray microanalysis

    International Nuclear Information System (INIS)

    Payne, C.M.; Cromey, D.W.

    1990-01-01

    A series of calcium phosphate standards having calcium/phosphorus (Ca/P) molar ratios of 0.50, 1.00, 1.50, and 1.67, respectively, was prepared for bulk specimen analysis using scanning electron microscopy (SEM) and energy-dispersive X-ray microanalysis (EDXA). The standards were mounted on carbon planchettes as either pure crystals or crystals embedded in epoxy resin. Ten different samples of each embedded and non-embedded standard were analyzed in a JEOL 100 CX electron microscope interfaced with a Kevex 8000 EDXA system using a lithium-drifted silicon detector and a multichannel analyzer. The Ca/P ratios were determined by calculating both net peak intensities without matrix corrections and atomic kappa-ratios using the MAGIC V computer program with ZAF correction factors for quantitative analysis. There was such extensive absorption of phosphorus X-rays in standards embedded in an epoxy matrix that the observed Ca/P ratios were statistically compatible with four different standards ranging in theoretical Ca/P ratios from 1.0 to 1.67. Although the non-embedded crystals showed a greater separation in the Ca/P ratios, both methods of preparation produced serious flaws in analysis. Direct application of the discovery of this caveat to the identification of suspected bone fragments for forensic science purposes is discussed

  3. USE OF ELECTRONIC EDUCATIONAL RESOURCES WHEN TRAINING IN WORK WITH SPREADSHEETS

    Directory of Open Access Journals (Sweden)

    Х А Гербеков

    2017-12-01

    Full Text Available Today the tools for maintaining training courses based on opportunities of information and communication technologies are developed. Practically in all directions of preparation and on all subject matters electronic textbook and self-instruction manuals are created. Nevertheless the industry of computer educational and methodical materials actively develops and gets more and more areas of development and introduction. In this regard more and more urgent is a problem of development of the electronic educational resources adequate to modern educational requirements. Creation and the organization of training courses with use of electronic educational resources in particular on the basis of Internet technologies remains a difficult methodical task.In article the questions connected with development of electronic educational resources for use when studying the substantial line “Information technologies” of a school course of informatics in particular for studying of spreadsheets are considered. Also the analysis of maintenance of a school course and the unified state examination from the point of view of representation of task in him corresponding to the substantial line of studying “Information technologies” on mastering technology of information processing in spreadsheets and the methods of visualization given by means of charts and schedules is carried out.

  4. Utility of replica techniques for x-ray microanalysis of second phase particles

    International Nuclear Information System (INIS)

    Bentley, J.

    1984-01-01

    X-ray microanalysis of second phase particles in ion-milled or electropolished thin foils is often complicated by the presence of the matrix nearby. Extraction replica techniques provide a means to avoid many of the complications of thin-foil analyses. In this paper, three examples of the analysis of second phase particles are described and illustrate the improvement obtained by the use of extraction replicas for qualitative analysis, quantitative analysis, and analysis of radioactive specimens

  5. Results of chemical microanalysis of selected stone artefacts from the collection of the State Archaeological Museum in Warsaw

    Czech Academy of Sciences Publication Activity Database

    Ježek, Martin; Płociński, T.

    2013-01-01

    Roč. 64, [1] (2013), s. 137-145 ISSN 0043-5082 Institutional support: RVO:67985912 Keywords : chemical microanalysis * SEM * whetstones * touchstones * precious metal Subject RIV: AC - Archeology, Anthropology, Ethnology

  6. Analytical Study of Usage of Electronic Information Resources at Pharmacopoeial Libraries in India

    Directory of Open Access Journals (Sweden)

    Sunil Tyagi

    2014-02-01

    Full Text Available The objective of this study is to know the rate and purpose of the use of e-resource by the scientists at pharmacopoeial libraries in India. Among other things, this study examined the preferences of the scientists toward printed books and journals, electronic information resources, and pattern of using e-resources. Non-probability sampling specially accidental and purposive technique was applied in the collection of primary data through administration of user questionnaire. The sample respondents chosen for the study consists of principle scientific officer, senior scientific officer, scientific officer, and scientific assistant of different division of the laboratories, namely, research and development, pharmaceutical chemistry, pharmacovigilance, pharmacology, pharmacogonosy, and microbiology. The findings of the study reveal the personal experiences and perceptions they have had on practice and research activity using e-resource. The major findings indicate that of the total anticipated participants, 78% indicated that they perceived the ability to use computer for electronic information resources. The data analysis shows that all the scientists belonging to the pharmacopoeial libraries used electronic information resources to address issues relating to drug indexes and compendia, monographs, drugs obtained through online databases, e-journals, and the Internet sources—especially polices by regulatory agencies, contacts, drug promotional literature, and standards.

  7. Page 170 Use of Electronic Resources by Undergraduates in Two ...

    African Journals Online (AJOL)

    undergraduate students use electronic resources such as NUC virtual library, HINARI, ... web pages articles from magazines, encyclopedias, pamphlets and other .... of Nigerian university libraries have Internet connectivity, some of the system.

  8. Model of e-learning with electronic educational resources of new generation

    Directory of Open Access Journals (Sweden)

    A. V. Loban

    2017-01-01

    Full Text Available Purpose of the article: improving of scientific and methodical base of the theory of the е-learning of variability. Methods used: conceptual and logical modeling of the е-learning of variability process with electronic educational resource of new generation and system analysis of the interconnection of the studied subject area, methods, didactics approaches and information and communication technologies means. Results: the formalization complex model of the е-learning of variability with electronic educational resource of new generation is developed, conditionally decomposed into three basic components: the formalization model of the course in the form of the thesaurusclassifier (“Author of e-resource”, the model of learning as management (“Coordination. Consultation. Control”, the learning model with the thesaurus-classifier (“Student”. Model “Author of e-resource” allows the student to achieve completeness, high degree of didactic elaboration and structuring of the studied material in triples of variants: modules of education information, practical task and control tasks; the result of the student’s (author’s of e-resource activity is the thesaurus-classifier. Model of learning as management is based on the principle of personal orientation of learning in computer environment and determines the logic of interaction between the lecturer and the student when determining the triple of variants individually for each student; organization of a dialogue between the lecturer and the student for consulting purposes; personal control of the student’s success (report generation and iterative search for the concept of the class assignment in the thesaurus-classifier before acquiring the required level of training. Model “Student” makes it possible to concretize the learning tasks in relation to the personality of the student and to the training level achieved; the assumption of the lecturer about the level of training of a

  9. A survey of the use of electronic scientific information resources among medical and dental students

    Directory of Open Access Journals (Sweden)

    Aarnio Matti

    2006-05-01

    Full Text Available Abstract Background To evaluate medical and dental students' utilization of electronic information resources. Methods A web survey sent to 837 students (49.9% responded. Results Twenty-four per cent of medical students and ninteen per cent of dental students searched MEDLINE 2+ times/month for study purposes, and thiry-two per cent and twenty-four per cent respectively for research. Full-text articles were used 2+ times/month by thirty-three per cent of medical and ten per cent of dental students. Twelve per cent of respondents never utilized either MEDLINE or full-text articles. In multivariate models, the information-searching skills among students were significantly associated with use of MEDLINE and full-text articles. Conclusion Use of electronic resources differs among students. Forty percent were non-users of full-text articles. Information-searching skills are correlated with the use of electronic resources, but the level of basic PC skills plays not a major role in using these resources. The student data shows that adequate training in information-searching skills will increase the use of electronic information resources.

  10. Transmission Electron Microscopy Physics of Image Formation

    CERN Document Server

    Kohl, Helmut

    2008-01-01

    Transmission Electron Microscopy: Physics of Image Formation presents the theory of image and contrast formation, and the analytical modes in transmission electron microscopy. The principles of particle and wave optics of electrons are described. Electron-specimen interactions are discussed for evaluating the theory of scattering and phase contrast. Also discussed are the kinematical and dynamical theories of electron diffraction and their applications for crystal-structure analysis and imaging of lattices and their defects. X-ray microanalysis and electron energy-loss spectroscopy are treated as analytical methods. Specimen damage and contamination by electron irradiation limits the resolution for biological and some inorganic specimens. This fifth edition includes discussion of recent progress, especially in the area of aberration correction and energy filtering; moreover, the topics introduced in the fourth edition have been updated. Transmission Electron Microscopy: Physics of Image Formation is written f...

  11. Access to electronic information resources by students of federal ...

    African Journals Online (AJOL)

    The paper discusses access to electronic information resources by students of Federal Colleges of Education in Eha-Amufu and Umunze. Descriptive survey design was used to investigate sample of 526 students. Sampling technique used was a Multi sampling technique. Data for the study were generated using ...

  12. Adoption and use of electronic information resources by medical ...

    African Journals Online (AJOL)

    This study investigated the adoption and use of electronic information resources by medical science students of the University of Benin. The descriptive survey research design was adopted for the study and 390 students provided the data. Data collected were analysed with descriptive Statistics(Simple percentage and ...

  13. Where Do Electronic Books Fit in the College Research Arsenal of Resources?

    Science.gov (United States)

    Barbier, Patricia

    2007-01-01

    Student use of electronic books has become an accepted supplement to traditional resources. Student use and satisfaction was monitored through an online course discussion board. Increased use of electronic books indicate this service is an accepted supplement to the print book collection.

  14. Characterisation of archaeological glass mosaics by electron microscopy and X-ray microanalysis

    International Nuclear Information System (INIS)

    Roe, M; Plant, S; Henderson, J; Andreescu-Treadgold, I; Brown, P D

    2006-01-01

    The combined techniques of scanning electron microscopy, energy dispersive X-ray analysis, transmission electron microscopy (TEM) and selected area electron diffraction are used to characterise the microstructures of opaque coloured glass mosaics from a mediaeval church in Torcello, Italy. Comparison of MgO/K 2 O ratios allows distinction between mediaeval and modern glass artefacts to be made. TEM investigation of inclusions indicates that relict silica is responsible for the speckled appearance of an impure mediaeval glass artefact, whilst a fine scale dispersion of elemental Cu nanoparticles is considered responsible for the orange-red colouration of a modern glass artefact

  15. Use of X-ray microanalysis for study of cation distribution in potassium deficient pumpkin roots

    Directory of Open Access Journals (Sweden)

    Natalia Burmistrova

    2014-01-01

    Full Text Available Ice slices of root tissues were investigated by X-ray microanalysis. It is shown that the cytoplasm of the meristematic and differentiated cells of potassium dificiest roots maintains a high potassium level. The vacuoles of various root cells loose more K and accumulate more Na and Mg than does the cytoplasm.

  16. 3D invariant embedding model for backscattering electrons applied to materials characterization

    International Nuclear Information System (INIS)

    Figueroa, C.; Nieva, N.; Heluani, S.P.

    2007-01-01

    In this work, the results of a 3D model used to describe the fraction of backscattered electrons, together with its energy and angular distributions, are reported. This 3D model is the result of improvements in the Invariant Embedding Approach to Microanalysis (IEAM). Comparisons with experiment show that the theoretical results follow the general trend of experimental data, when parameters (such as atomic number, energy of the impinging electrons and tilted angle) are changed

  17. Calculations of atomic sputtering and displacement cross-sections in solid elements by electrons with energies from threshold to 1.5 MV

    International Nuclear Information System (INIS)

    Bradley, C.R.

    1988-12-01

    The kinetics of knock-on collisions of relativistic electrons with nuclei and details of the numerical evaluation of differential, recoil, and total Mott cross-sections are reviewed and discussed. The effects of electron beam induced displacement and sputtering, in the transmission electron microscope (TEM) environment, on microanalysis are analyzed with particular emphasis placed on the removal of material by knock-on sputtering. The mass loss predicted due to transmission knock-on sputtering is significant for many elements under conditions frequently encountered in microanalysis. Total Mott cross-sections are tabulated for all naturally occurring solid elements up to Z = 92 at displacement energies of one, two, four, and five times the sublimation energy and for accelerating voltages accessible in the transmission electron microscope. Fortran source code listings for the calculation of the differential Mott cross-section as a function of electron scattering angle (dMottCS), as a function of nuclear recoil angle (RECOIL), and the total Mott cross-section (TOTCS) are included. 48 refs., 21 figs., 12 tabs

  18. Strategic Planning for Electronic Resources Management: A Case Study at Gustavus Adolphus College

    Science.gov (United States)

    Hulseberg, Anna; Monson, Sarah

    2009-01-01

    Electronic resources, the tools we use to manage them, and the needs and expectations of our users are constantly evolving; at the same time, the roles, responsibilities, and workflow of the library staff who manage e-resources are also in flux. Recognizing a need to be more intentional and proactive about how we manage e-resources, the…

  19. REVIEW OF MOODLE PLUGINS FOR DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES FROM LANGUAGE DISCIPLINES

    Directory of Open Access Journals (Sweden)

    Anton M. Avramchuk

    2015-09-01

    Full Text Available Today the problem of designing multimedia electronic educational resources from language disciplines in Moodle is very important. This system has a lot of different, powerful resources, plugins to facilitate the learning of students with language disciplines. This article presents an overview and comparative analysis of the five Moodle plugins for designing multimedia electronic educational resources from language disciplines. There have been considered their key features and functionality in order to choose the best for studying language disciplines in the Moodle. Plugins are compared by a group of experts according to the criteria: efficiency, functionality and easy use. For a comparative analysis of the plugins it is used the analytic hierarchy process.

  20. Modern ICT Tools: Online Electronic Resources Sharing Using Web ...

    African Journals Online (AJOL)

    Modern ICT Tools: Online Electronic Resources Sharing Using Web 2.0 and Its Implications For Library And Information Practice In Nigeria. ... The PDF file you selected should load here if your Web browser has a PDF reader plug-in installed (for example, a recent version of Adobe Acrobat Reader). If you would like more ...

  1. Structure and properties of an aluminium alloy welded by electron beam

    International Nuclear Information System (INIS)

    Ruzimov, Sh.M.; Palvanov, S.R.; Pogrebnjak, A.D.

    2005-01-01

    Full text: In the given work the experimental results on research of influence of electronic beams on structure of an aluminum alloy are submitted. As a basis of samples the alloy Al-Mg-Zn-Cu by the additives Se-0.5 % and Nb-0.15 % is chosen. Samples from a cast aluminum alloy by thickness of 3 mm such as B-96 were welded with an electronic beam in three different modes at radius circle of a root of a welded seam of 5 mm. The welding was carried out by an alloy Amg 63 and Sv-1571 with application electron team welding joint of parts. The basic influence on the given process makes energy - allocation of an electronic beam. For research of phase structure used of X-ray beams (XRD), DRON-2 in copper K α - Cu measurement. For research of structure and morphology of a surface used optical microscope with increase 800-1500 times and electronic microscope with the microanalysis. On figures of optical microscopy the morphology of a seam sharply differs from morphology of an initial part. The microanalysis carried out with a place of a seam, has shown presence of the whole spectrum of elements, such as, Al; Zn; Na; Mg; Cu; and Mn. All measurements carried out in welding zone and in frontier zones that it was possible to carry out the comparative analysis. The element structure of these zones essentially differs in dependence of a condition of welding

  2. 2nd International Multidisciplinary Microscopy and Microanalysis Congress

    CERN Document Server

    Oral, Ahmet; Ozer, Mehmet

    2015-01-01

    The 2nd International Multidisciplinary Microscopy and Microanalysis Congress & Exhibition (InterM 2014) was held on 16–19 October 2014 in Oludeniz, Fethiye/ Mugla, Turkey. The aim of the congress was to gather scientists from various branches and discuss the latest improvements in the field of microscopy. The focus of the congress has been widened in an "interdisciplinary" manner, so as to allow all scientists working on several related subjects to participate and present their work. These proceedings include 33 peer-reviewed technical papers, submitted by leading academic and research institutions from over 17 countries and representing some of the most cutting-edge research available. The papers were presented at the congress in the following sessions: ·         Applications of Microscopy in the Physical Sciences ·         Applications of Microscopy in the Biological Sciences.

  3. Surface characterization by energy distribution measurements of secondary electrons and of ion-induced electrons

    International Nuclear Information System (INIS)

    Bauer, H.E.; Seiler, H.

    1988-01-01

    Instruments for surface microanalysis (e.g. scanning electron or ion microprobes, emission electron or ion microscopes) use the current of emitted secondary electrons or of emitted ion-induced electrons for imaging of the analysed surface. These currents, integrating over all energies of the emitted low energy electrons, are however, not well suited to surface analytical purposes. On the contrary, the energy distribution of these electrons is extremely surface-sensitive with respect to shape, size, width, most probable energy, and cut-off energy. The energy distribution measurements were performed with a cylindrical mirror analyser and converted into N(E), if necessary. Presented are energy spectra of electrons released by electrons and argon ions of some contaminated and sputter cleaned metals, the change of the secondary electron energy distribution from oxidized aluminium to clean aluminium, and the change of the cut-off energy due to work function change of oxidized aluminium, and of a silver layer on a platinum sample. The energy distribution of the secondary electrons often shows detailed structures, probably due to low-energy Auger electrons, and is broader than the energy distribution of ion-induced electrons of the same object point. (author)

  4. Quantitative X-ray spectral microanalysis of bioorganic films by means of a crystal-diffraction spectrometer

    International Nuclear Information System (INIS)

    Pogorelov, A.G.; Pogorelova, V.N.; Khrenova, E.V.; Gol'dshtejn, D.V.; Aksirov, A.M.; Kantor, G.M.

    2005-01-01

    The details of the quantitative X-ray spectral microanalysis performed with a wave dispersive spectrometer are described. Hydration of biological tissues, light element composition, low concentration of analyzed elements and their nonuniform distribution are the specific features of bioorganic film and tissue section. This paper is aimed to discuss the general approaches to both preparation technique and quantitative analysis principles [ru

  5. THE MODEL OF LINGUISTIC TEACHERS’ COMPETENCY DEVELOPMENT ON DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES IN THE MOODLE SYSTEM

    Directory of Open Access Journals (Sweden)

    Anton M. Avramchuk

    2017-10-01

    Full Text Available The article is devoted to the problem of developing the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system. The concept of "the competence of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system" is justified and defined. Identified and characterized the components by which the levels of the competency development of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system should be assessed. Developed a model for the development of the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system, which is based on the main scientific approaches, used in adult education, and consists of five blocks: target, informative, technological, diagnostic and effective.

  6. Developing Humanities Collections in the Digital Age: Exploring Humanities Faculty Engagement with Electronic and Print Resources

    Science.gov (United States)

    Kachaluba, Sarah Buck; Brady, Jessica Evans; Critten, Jessica

    2014-01-01

    This article is based on quantitative and qualitative research examining humanities scholars' understandings of the advantages and disadvantages of print versus electronic information resources. It explores how humanities' faculty members at Florida State University (FSU) use print and electronic resources, as well as how they perceive these…

  7. Comparison of STIM and particle backscattering spectrometry mass determination for quantitative microanalysis of cultured cells

    International Nuclear Information System (INIS)

    Deves, G.; Ortega, R.

    2001-01-01

    In biological sample microanalysis, a mass-normalisation method is commonly used as a quantitative index of elemental concentrations determined by particle-induced X-ray emission (PIXE). The organic mass can either be determined using particle backscattering spectrometry (BS) or scanning transmission ion microscopy (STIM). However, the accuracy of quantitative microanalysis in samples such as cultured cells is affected by beam-induced loss of organic mass during analysis. The aim of this paper is to compare mass measurements determined by particle BS or by STIM. In order to calibrate STIM and BS analyses, we measured by both techniques the thickness of standard foils of polycarbonate (3 and 6 μm), Mylar[reg] (4 μm), Kapton[reg] (7.5 μm) and Nylon[reg] (15 μm), as well as biological samples of mono-layered cultured cells. Non-damaging STIM analysis of samples before PIXE irradiation is certainly one of the most accurate ways to determine the sample mass, however, this requires strong experimental handling. On the other hand, BS performed simultaneously to PIXE is the simplest method to determine the local mass in polymer foils, but appears less accurate in the case of cultured cells

  8. Microanalysis on the Hydrogen Ion Irradiated 50 wt pct TiC-C Films

    Institute of Scientific and Technical Information of China (English)

    Hui JIANG; Yaoguang LIU; Ningkang HUANG

    2007-01-01

    The 50 wt pct TiC-C films were prepared on stainless steel substrates by using a technique of ion beam mixing.These films were irradiated by hydrogen ion beam with a dose of 1×1018 ions/cm2 and an energy of 5 keV.Microanalysis of X-ray photoelectron spectroscopy (XPS) and secondary ion mass spectroscopy (SIMS) were used to analyze the films before and after hydrogen ion irradiation and to study the mechanism of hydrogen resistance.

  9. Electronic resource management systems a workflow approach

    CERN Document Server

    Anderson, Elsa K

    2014-01-01

    To get to the bottom of a successful approach to Electronic Resource Management (ERM), Anderson interviewed staff at 11 institutions about their ERM implementations. Among her conclusions, presented in this issue of Library Technology Reports, is that grasping the intricacies of your workflow-analyzing each step to reveal the gaps and problems-at the beginning is crucial to selecting and implementing an ERM. Whether the system will be used to fill a gap, aggregate critical data, or replace a tedious manual process, the best solution for your library depends on factors such as your current soft

  10. Electronic Resource Management System. Vernetzung von Lizenzinformationen

    Directory of Open Access Journals (Sweden)

    Michaela Selbach

    2014-12-01

    Full Text Available In den letzten zehn Jahren spielen elektronische Ressourcen im Bereich der Erwerbung eine zunehmend wichtige Rolle: Eindeutig lässt sich hier ein Wandel in den Bibliotheken (fort vom reinen Printbestand zu immer größeren E-Only-Beständen feststellen. Die stetig wachsende Menge an E-Ressourcen und deren Heterogenität stellt Bibliotheken vor die Herausforderung, die E-Ressourcen effizient zu verwalten. Nicht nur Bibliotheken, sondern auch verhandlungsführende Institutionen von Konsortial- und Allianzlizenzen benötigen ein geeignetes Instrument zur Verwaltung von Lizenzinformationen, welches den komplexen Anforderungen moderner E-Ressourcen gerecht wird. Die Deutsche Forschungsgemeinschaft (DFG unterstützt ein Projekt des Hochschulbibliothekszentrums des Landes Nordrhein-Westfalen (hbz, der Universitätsbibliothek Freiburg, der Verbundzentrale des Gemeinsamen Bibliotheksverbundes (GBV und der Universitätsbibliothek Frankfurt, in dem ein bundesweit verfügbares Electronic Ressource Managementsystem (ERMS aufgebaut werden soll. Ein solches ERMS soll auf Basis einer zentralen Knowledge Base eine einheitliche Nutzung von Daten zur Lizenzverwaltung elektronischer Ressourcen auf lokaler, regionaler und nationaler Ebene ermöglichen. Statistische Auswertungen, Rechteverwaltung für alle angeschlossenen Bibliotheken, kooperative Datenpflege sowie ein über standardisierte Schnittstellen geführter Datenaustausch stehen bei der Erarbeitung der Anforderungen ebenso im Fokus wie die Entwicklung eines Daten- und Funktionsmodells. In the last few years the importance of electronic resources in library acquisitions has increased significantly. There has been a shift from mere print holdings to both e- and print combinations and even e-only subscriptions. This shift poses a double challenge for libraries: On the one hand they have to provide their e-resource collections to library users in an appealing way, on the other hand they have to manage these

  11. An integrated electron and optical metallographic procedure for the identification of precipitate phases in type 316 stainless steel

    International Nuclear Information System (INIS)

    Slattery, G.F.; O'Riordan, P.; Lambert, M.E.; Green, S.M.

    1981-01-01

    A sequential and integrated metallographic procedure has been developed and successfully employed to differentiate between carbide, sigma, chi, Laves and ferrite phases which are commonly encountered in type 316 austenitic steel. The experimental techniques of optical and electron microscopy to identify these phases have been outlined and provide a rapid and convenient method of characterizing the microstructure of the steel. The techniques sequence involves selective metallographic etching, Nomarski interference microscopy, scanning electron microscopy, energy dispersive microanalysis, transmission electron microscopy and electron diffraction. (author)

  12. Ultrastructural localization of lead in Stigeoclonium tenue (chlorophyceae, ulotrichales) as demonstrated by cytochemical and x-ray microanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Silverberg, B A

    1975-12-01

    Results of ultrastructural studies and TEM-X-ray microanalysis of the ulotrichalean alga Stigeoclonium tenue experimentally exposed to increasing concentrations of lead nitrate are presented. A fine-structural examination of the cells revealed that detectable amounts of lead (Pb) had entered the cytoplasm and could be recognized most easily as electron-dense precipitates localized on the cell wall and within the two large peripheral vacuoles. Dense deposits were never observed in mitochondria, plastids or nuclei. Pinocytotic vacuoles containing lead spheroids are removed endocytotically to the cytoplasmic vacuoles, rendering the Pb innocuous. The evidence suggests that the cell wall and vacuoles are important structures in maintaining a relatively low cytoplasmic concentration of lead, thereby reducing the toxic effects of lead ions on sensitive cellular functions. At high concentrations, ranging from 0.15 to 0.5 mg Pb/l, noticeable alterations in the fine structure of the chloroplast are evident. A method is described for the visualization of Pb deposits in fresh, chemically fixed and plastic-embedded material using a saturated solution of sodium rhodizonate.

  13. FIB preparation of a NiO Wedge-Lamella and STEM X-ray microanalysis for the determination of the experimental k(O-Ni) Cliff-Lorimer coefficient.

    Science.gov (United States)

    Armigliato, Aldo; Frabboni, Stefano; Gazzadi, Gian Carlo; Rosa, Rodolfo

    2013-02-01

    A method for the fabrication of a wedge-shaped thin NiO lamella by focused ion beam is reported. The starting sample is an oxidized bulk single crystalline, oriented, Ni commercial standard. The lamella is employed for the determination, by analytical electron microscopy at 200 kV of the experimental k(O-Ni) Cliff-Lorimer (G. Cliff & G.W. Lorimer, J Microsc 103, 203-207, 1975) coefficient, according to the extrapolation method by Van Cappellen (E. Van Cappellen, Microsc Microstruct Microanal 1, 1-22, 1990). The result thus obtained is compared to the theoretical k(O-Ni) values either implemented into the commercial software for X-ray microanalysis quantification of the scanning transmission electron microscopy/energy dispersive spectrometry equipment or calculated by the Monte Carlo method. Significant differences among the three values are found. This confirms that for a reliable quantification of binary alloys containing light elements, the choice of the Cliff-Lorimer coefficients is crucial and experimental values are recommended.

  14. Automated electron microprobe

    International Nuclear Information System (INIS)

    Thompson, K.A.; Walker, L.R.

    1986-01-01

    The Plant Laboratory at the Oak Ridge Y-12 Plant has recently obtained a Cameca MBX electron microprobe with a Tracor Northern TN5500 automation system. This allows full stage and spectrometer automation and digital beam control. The capabilities of the system include qualitative and quantitative elemental microanalysis for all elements above and including boron in atomic number, high- and low-magnification imaging and processing, elemental mapping and enhancement, and particle size, shape, and composition analyses. Very low magnification, quantitative elemental mapping using stage control (which is of particular interest) has been accomplished along with automated size, shape, and composition analysis over a large relative area

  15. The Electron Microscopy Outreach Program: A Web-based resource for research and education.

    Science.gov (United States)

    Sosinsky, G E; Baker, T S; Hand, G; Ellisman, M H

    1999-01-01

    We have developed a centralized World Wide Web (WWW)-based environment that serves as a resource of software tools and expertise for biological electron microscopy. A major focus is molecular electron microscopy, but the site also includes information and links on structural biology at all levels of resolution. This site serves to help integrate or link structural biology techniques in accordance with user needs. The WWW site, called the Electron Microscopy (EM) Outreach Program (URL: http://emoutreach.sdsc.edu), provides scientists with computational and educational tools for their research and edification. In particular, we have set up a centralized resource containing course notes, references, and links to image analysis and three-dimensional reconstruction software for investigators wanting to learn about EM techniques either within or outside of their fields of expertise. Copyright 1999 Academic Press.

  16. Technical Communicator: A New Model for the Electronic Resources Librarian?

    Science.gov (United States)

    Hulseberg, Anna

    2016-01-01

    This article explores whether technical communicator is a useful model for electronic resources (ER) librarians. The fields of ER librarianship and technical communication (TC) originated and continue to develop in relation to evolving technologies. A review of the literature reveals four common themes for ER librarianship and TC. While the…

  17. Quantification of multielement-multilayer-samples in electron probe analysis

    International Nuclear Information System (INIS)

    Pfeiffer, A.

    1995-03-01

    The following dissertation presents the theoretical basis of analytical correction models and Monte Carlo simulations in the field of electron probe microanalysis to describe the excitation conditions of x-rays in a multilayer-multielement-sample. In this connection analyzing programs have been developed to make a quantitative investigation of heterogeneous samples possible. In the work the mathematical methods and formulas, which are mainly based on empirical and semiempirical findings, are described and their validity is discussed in detail. Especially the improvements of the 'multiple reflections'-model by August are compared with the Φ(ρz)-models by Pouchou, Merlet and Bastin. The calculations of depth distribution functions for characteristics and continuous fluorescence excitation result in a consistent and completeΦ(ρz)-model. This allows to analyze layered structures in great detail. Because of the increasing importance in electron probe microanalysis and as a reference method a Monte Carlo model is described. With this model electron trajectories and excitation conditions in arbitrary two dimensional geometries can be calculated. The validity of the analytical model is proven with a comprehensive comparison of results of new calculations to published data. To show an application of the programs and models in routine use in the industrial research and development, a quantitative analysis of a Co/Si system is made. In the conclusion of this dissertation some reflections upon investigations, which are based on this work and which should be made in future are outlined. (author)

  18. MODEL OF AN ELECTRONIC EDUCATIONAL RESOURCE OF NEW GENERATION

    Directory of Open Access Journals (Sweden)

    Anatoliy V. Loban

    2016-01-01

    Full Text Available The mathematical structure of the modular architecture of an electronic educational resource (EER of new generation, which allows to decompose the process of studying the subjects of the course at a hierarchically ordered set of data (knowledge and procedures for manipulating them, to determine the roles of participants of process of training of and technology the development and use of EOR in the study procrate.

  19. IMAP: A complete Ion Micro-Analysis Package for the nuclear microprobe

    International Nuclear Information System (INIS)

    Antolak, A.J.; Hildner, M.L.; Morse, D.H.; Bench, G.S.

    1993-01-01

    Microprobe techniques using scanned, focused MeV ions are routinely used in Livermore for materials characterization. Comprehensive data analysis with these techniques is accomplished with the computer software package IMAP, for Ion Micro-Analysis Package. IMAP consists of a set of command language procedures for data processing and quantitative spectral analysis. Deconvolution of the data is achieved by spawning sub-processes within IMAP which execute analysis codes for each specific microprobe technique. IMAP is structured to rapidly analyze individual spectra or multi-dimensional data blocks which classify individual events by the two scanning dimensions, the energy of the detected radiation and, when necessary, one sample rotation dimension. Several examples are presented to demonstrate the utility of the package

  20. Diagnosis of early human myocardial ischemic damage with electron probe microanalysis

    International Nuclear Information System (INIS)

    Singh, S.; Abraham, J.L.; Raasch, F.; Wolf, P.; Bloor, C.M.

    1983-01-01

    We determined the Na/K x-ray intensity ratio in frozen sections of myocardial tissues obtained at autopsy from patients who died from various causes, using electron probe analysis. We have been able to distinguish between the ischemically injured and normal cells. The method is simple, fast, and dependable even when the duration of ischemia is only 30 minutes

  1. Mass determination based on electron scattering in electron probe X-ray microanalysis of thin biological specimens

    International Nuclear Information System (INIS)

    Linders, P.W.J.

    1984-01-01

    This thesis describes the development of a method for mass determination of thin biological objects by quantitative electron microscopy. The practical realization of the mass determination consists of photographical recording with subsequent densitometry. (Auth.)

  2. Microstructure and microanalysis of some ancient building materials

    International Nuclear Information System (INIS)

    Majumdar, A.J.; Rayment, D.L.; Pettifer, K.

    1988-12-01

    In order to assess the very long term of durability of modern Portland cements for encapsulating certain types of radioactive waste, the microstructure and microanalysis of concretes of various ages made from such cements are compared with those from similar materials of ancient origins with ages upto 2500 years used in early Greek, Roman and British Construction. Most of the historical 'concretes' examined were heavily carbonated and at best showed only traces of the calcium silicate hydrate (C-S-H) phase, the heart of modern Portland Cement concretes. The notable exception was the 1700 years old concrete from Hadrian's Wall - the mortar in this was rich in C-S-H. The modern concrete samples, from 10 to 140 years old, showed little carbonation and their compositions of the C-S-H phase were very similar to those found from Hadrian's Wall. From all the evidence examined, it is concluded that the C-S-H phase is capable of surviving intact for several thousands of years in the absence of external chemical attack. (author)

  3. Scanning electron-microscopic and X-ray-microanalytic observation of diesel-emission particles associated with mutagenicity

    International Nuclear Information System (INIS)

    Nakashima, K.; Yoshitsugu, K.; Tokiwa, H.; Fukuoka Environmental Research Center

    1983-01-01

    The particles formed by diesel combustion, which may contain various mutagenic chemicals like polycyclic aromatic hydrocarbons (PAH), are analyzed in their morphology by scanning electron microscopy; their sulfur content is detected by X-ray microanalysis, and mutagenicity is tested with a Salmonella typhimurium bioassay. The authors find a close correlation between sulfur content and mutagenicity of PAH. (Auth.)

  4. Study on methods of quantitative analysis of the biological thin samples in EM X-ray microanalysis

    International Nuclear Information System (INIS)

    Zhang Detian; Zhang Xuemin; He Kun; Yang Yi; Zhang Sa; Wang Baozhen

    2000-01-01

    Objective: To study the methods of quantitative analysis of the biological thin samples. Methods: Hall theory was used to study the qualitative analysis, background subtraction, peel off overlap peaks; external radiation and aberrance of spectra. Results: The results of reliable qualitative analysis and precise quantitative analysis were achieved. Conclusion: The methods for analysis of the biological thin samples in EM X-ray microanalysis can be used in biomedical research

  5. The uses of synchrotron radiation sources for elemental and chemical microanalysis

    Science.gov (United States)

    Chen, J.R.; Chao, E.C.T.; Minkin, J.A.; Back, J.M.; Jones, K.W.; Rivers, M.L.; Sutton, S.R.

    1990-01-01

    Synchrotron radiation sources offer important features for the analysis of a material. Among these features is the ability to determine both the elemental composition of the material and the chemical state of its elements. For microscopic analysis synchrotron X-ray fluorescence (SXRF) microprobes now offer spatial resolutions of 10 ??m with minimum detection limits in the 1-10 ppm range depending on the nature of the sample and the synchrotron source used. This paper describes the properties of synchrotron radiation and their importance for elemental analysis, existing synchrotron facilities and those under construction that are optimum for SXRF microanalysis, and a number of applications including the high energy excitation of the K lines of heavy elements, microtomography, and XANES and EXAFS spectroscopies. ?? 1990.

  6. Metal X-ray microanalysis in the olfactory system of rainbow trout exposed to low level of copper

    International Nuclear Information System (INIS)

    Julliard, A.K.; Astic, L.; Saucier, D.

    1995-01-01

    It has recently been shown that a chronic copper exposure induces specific degeneration of olfactory receptor cells in rainbow trout; however, the exact mechanism of action of the metal is not yet known. Using X-ray microanalysis in transmission electron microscopy, we have studied the distribution of metal in the olfactory system of fish exposed for 15,30 and 60 days to 20 μg/l of copper. This was done in order to determine if it was accumulated in receptor cells and transported into the central nervous system via the olfactory nerve. No copper accumulation was detected either in the olfactory epithelium, in the olfactory nerve or in the olfactory bulb. The heavy metal was exclusively found within melanosomes of melanophores located in the lamina propria. After 60 days of exposure, the copper content in melanosomes was about two-fold higher than that in controls. As far as some morphological recovery took place in the olfactory organ during the metal exposure, which lets us suppose that some detoxication mechanism occurs, it could be suggested that metanophores might be somehow involved in such a mechanism. (authors). 57 refs., 15 figs

  7. Electron probe micro-analysis of gas bubbles in solids: a novel approach

    International Nuclear Information System (INIS)

    Verwerft, M.; Vos, B.

    1999-01-01

    The local analysis of retained noble gas in nuclear fuel is inherently difficult since the physical form under which it is stored varies from atomically dispersed to bubbles with a diameter of several hundreds of nanometers. One of the techniques that has been applied since pore than twenty years is EPMA. Although many important results have been obtained with this technique, its application to the analysis of highly inhomogeneous materials is limited. The EPMA technique is indeed difficult to apply to samples that are not homogeneous on the scale of the electron-solid interaction volume. The paper discusses the development of a method to analyse a system of as bubbles distributed in a solid matrix. This method has been based on a multiple voltage EPMA measurement combined with a scanning Electron Microscopic analysis of the bubble size distribution

  8. GUIDELINES FOR EVALUATION OF PSYCHOLOGICAL AND PEDAGOGICAL QUALITY CHARACTERISTICS OF ELECTRONIC EDUCATIONAL RESOURCES

    Directory of Open Access Journals (Sweden)

    Galina P. Lavrentieva

    2014-05-01

    Full Text Available The article highlights the causes of insufficient effective use of electronic learning resources and sets out the guidelines on ways to solve the aforementioned problems. The set of didactic, methodical, psychological, pedagogical, design and ergonomic quality requirements is considered for evaluation, selection and application of information and communication technologies in the educational process. The most appropriate mechanisms for the ICT introduction into the learning process are disclosed as it should meet the specific learning needs of the student and the objectives of the educational process. The guidance for psycho-educational assessment of quality of electronic educational resources is provided. It is argued that the effectiveness of the ICT use is to be improved by means of quality evaluation mechanisms involved into the educational process.

  9. Availability, Use and Constraints to Use of Electronic Information Resources by Postgraduates Students at the University of Ibadan

    Directory of Open Access Journals (Sweden)

    Dare Samuel Adeleke

    2017-12-01

    Full Text Available Availability, awareness and use of electronic resources provide access to authoritative, reliable, accurate and timely access to information. The use of electronic information resources (EIRs can enable innovation in teaching and increase timeliness in research of postgraduate students which will eventual result into encouragement of the expected research-led enquiry in this digital age. The study adopted a descriptive survey design. Samples of 300 of postgraduate students within seven out 13 Faculties were randomly selected. Data were collected using questionnaire designed to elicit response from respondents and data were analyzed using descriptive statistics methods percentages, mean, and standard deviation. Results indicated that internet was ranked most available and used in the university. Low level of usage of electronic resources, in particular, full texts data bases is linked to a number of constraints: Interrupted power supply was ranked highest among other factors as speed and capacity of computers, retrieval of records with high recall and low precision, retrieving records relevant to information need, lack of knowledge of search techniques to retrieve information effectively, non possession of requisite IT skills and problems accessing the internet. The study recommended that usage of electronic resources be made compulsory, intensifying awareness campaigns concerning the availability, training on use of electronic resources and the problem of power outage be addressed.

  10. A Study on Developing Evaluation Criteria for Electronic Resources in Evaluation Indicators of Libraries

    Science.gov (United States)

    Noh, Younghee

    2010-01-01

    This study aimed to improve the current state of electronic resource evaluation in libraries. While the use of Web DB, e-book, e-journal, and other e-resources such as CD-ROM, DVD, and micro materials is increasing in libraries, their use is not comprehensively factored into the general evaluation of libraries and may diminish the reliability of…

  11. A new standardless quantitative electron probe microanalysis technique applied to III-V compound semiconductors

    International Nuclear Information System (INIS)

    Zangalis, K.P.; Christou, A.

    1982-01-01

    The present paper introduces a new standardless quantitative scheme for off-line electron microprobe analysis applications. The analysis is based on standard equations of the type Isub(i)=Csub(i)fsub(ZAF)βsub(i) and is specifically suitable for compound semiconductors. The roots to the resultant nth-degree polynomial are the unknown concentrations. Methods for computing Csub(i) when coefficients βsub(i) are unknown are also outlined. Applications of standardless analysis to GaAs and InP specimens are compared with results obtained by Auger electron spectroscopy and quantitative electron probe analysis with standards. (Auth.)

  12. The uses of synchrotron radiation sources for elemental and chemical microanalysis

    International Nuclear Information System (INIS)

    Chen, J.R.; Chao, E.C.T.; Minkin, J.A.; Back, J.M.; Jones, K.W.; Rivers, M.L.; Sutton, S.R.

    1989-08-01

    Synchrotron radiation sources offer important features for the analysis of a material. Among these features is the ability to determine both the elemental composition of the material and the chemical state of its elements. For microscopic analysis synchrotron x-ray fluorescence (SXRF) microprobes now offer spatial resolutions of 10μm with minimum detection limits in the 1--10 ppM range depending on the nature of the sample and the synchrotron source used. This paper describes the properties of synchrotron radiation and their importance for elemental analysis, existing synchrotron facilities and those under construction that are optimum for SXRF microanalysis, and a number of applications including the high energy excitation of the K lines of heavy elements, microtomography, and XANES and EXAFS spectroscopies. 45 refs., 8 figs., 1 tab

  13. THE MODEL OF LINGUISTIC TEACHERS’ COMPETENCY DEVELOPMENT ON DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES IN THE MOODLE SYSTEM

    OpenAIRE

    Anton M. Avramchuk

    2017-01-01

    The article is devoted to the problem of developing the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system. The concept of "the competence of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system" is justified and defined. Identified and characterized the components by which the levels of the competency development of teachers of language disciplines on designing ...

  14. Determining the level of awareness of the physicians in using the variety of electronic information resources and the effecting factors.

    Science.gov (United States)

    Papi, Ahmad; Ghazavi, Roghayeh; Moradi, Salimeh

    2015-01-01

    Understanding of the medical society's from the types of information resources for quick and easy access to information is an imperative task in medical researches and management of the treatment. The present study was aimed to determine the level of awareness of the physicians in using various electronic information resources and the factors affecting it. This study was a descriptive survey. The data collection tool was a researcher-made questionnaire. The study population included all the physicians and specialty physicians of the teaching hospitals affiliated to Isfahan University of Medical Sciences and numbered 350. The sample size based on Morgan's formula was set at 180. The content validity of the tool was confirmed by the library and information professionals and the reliability was 95%. Descriptive statistics were used including the SPSS software version 19. On reviewing the need of the physicians to obtain the information on several occasions, the need for information in conducting the researches was reported by the maximum number of physicians (91.9%) and the usage of information resources, especially the electronic resources, formed 65.4% as the highest rate with regard to meeting the information needs of the physicians. Among the electronic information databases, the maximum awareness was related to Medline with 86.5%. Among the various electronic information resources, the highest awareness (43.3%) was related to the E-journals. The highest usage (36%) was also from the same source. The studied physicians considered the most effective deterrent in the use of electronic information resources as being too busy and lack of time. Despite the importance of electronic information resources for the physician's community, there was no comprehensive knowledge of these resources. This can lead to less usage of these resources. Therefore, careful planning is necessary in the hospital libraries in order to introduce the facilities and full capabilities of the

  15. Managing Selection for Electronic Resources: Kent State University Develops a New System to Automate Selection

    Science.gov (United States)

    Downey, Kay

    2012-01-01

    Kent State University has developed a centralized system that manages the communication and work related to the review and selection of commercially available electronic resources. It is an automated system that tracks the review process, provides selectors with price and trial information, and compiles reviewers' feedback about the resource. It…

  16. End-of-life resource recovery from emerging electronic products

    DEFF Research Database (Denmark)

    Parajuly, Keshav; Habib, Komal; Cimpan, Ciprian

    2016-01-01

    Integrating product design with appropriate end-of-life (EoL) processing is widely recognized to have huge potentials in improving resource recovery from electronic products. In this study, we investigate both the product characteristics and EoL processing of robotic vacuum cleaner (RVC), as a case...... of emerging electronic product, in order to understand the recovery fate of different materials and its linkage to product design. Ten different brands of RVC were dismantled and their material composition and design profiles were studied. Another 125 RVCs (349 kg) were used for an experimental trial...... at a conventional ‘shred-and-separate’ type preprocessing plant in Denmark. A detailed material flow analysis was performed throughout the recycling chain. The results show a mismatch between product design and EoL processing, and the lack of practical implementation of ‘Design for EoL’ thinking. In the best...

  17. Element concentrations in the intestinal mucosa of the mouse as measured by X-ray microanalysis

    International Nuclear Information System (INIS)

    Zglinicki, T. von; Roomans, G.M.

    1989-01-01

    Subcellular ion distribution in villus, crypt, Paneth and smooth muscle cells of the mouse small intestine under resting conditions was investigated by X-ray microanalysis of ultrathin cryosections. In addition, the mass distribution was estimated by measuring the optical transmission of the compartments in transmission electron micrographs. Each cell type is characterized by a special composition in terms of the major monovalent ions Na, K, and Cl. In particular, among crypt epithelial cells, those cells containing small secretion granula (termed crypt A cells) also display cytoplasmic ion concentrations significantly different from crypt epithelial cells lacking secretion granula (crypt B cells). Monovalent ion concentrations in the cytoplasm of Paneth cells, muscle cells, and crypt epithelial cells lacking secretion granula are higher than expected from osmotic considerations. Hence, significant binding of ions to cytoplasmic polyelectrolytes is assumed in these cells. There are gradients of dry mass and K concentration from the luminal to the basal side of the cell, both in crypt and in villus cells. The terminal web in these cells is rich in Na and Cl. The elemental composition of the large, dark secretion granula in Paneth cells is similar to that of the small dark granula in crypt cells. However, the two morphologically different types of granula within the Paneth cells have a significantly different elemental composition, which might reflect maturation of secretion granula

  18. Use of electronic sales data to tailor nutrition education resources for an ethnically diverse population.

    Science.gov (United States)

    Eyles, H; Rodgers, A; Ni Mhurchu, C

    2010-02-01

    Nutrition education may be most effective when personally tailored. Individualised electronic supermarket sales data offer opportunities to tailor nutrition education using shopper's usual food purchases. The present study aimed to use individualised electronic supermarket sales data to tailor nutrition resources for an ethnically diverse population in a large supermarket intervention trial in New Zealand. Culturally appropriate nutrition education resources (i.e. messages and shopping lists) were developed with the target population (through two sets of focus groups) and ethnic researchers. A nutrient database of supermarket products was developed using retrospective sales data and linked to participant sales to allow tailoring by usual food purchases. Modified Heart Foundation Tick criteria were used to identify 'healthier' products in the database suitable for promotion in the resources. Rules were developed to create a monthly report listing the tailored and culturally targeted messages to be sent to each participant, and to produce automated, tailored shopping lists. Culturally targeted nutrition messages (n = 864) and shopping lists (n = 3 formats) were developed. The food and nutrient database (n = 3000 top-selling products) was created using 12 months of retrospective sales data, and comprised 60%'healthier' products. Three months of baseline sales data were used to determine usual food purchases. Tailored resources were successfully mailed to 123 Māori, 52 Pacific and 346 non-Māori non-Pacific participants over the 6-month trial intervention period. Electronic supermarket sales data can be used to tailor nutrition education resources for a large number of ethnically diverse supermarket shoppers.

  19. Availability, Level of Use and Constraints to Use of Electronic Resources by Law Lecturers in Public Universities in Nigeria

    Science.gov (United States)

    Amusa, Oyintola Isiaka; Atinmo, Morayo

    2016-01-01

    (Purpose) This study surveyed the level of availability, use and constraints to use of electronic resources among law lecturers in Nigeria. (Methodology) Five hundred and fifty-two law lecturers were surveyed and four hundred and forty-two responded. (Results) Data analysis revealed that the level of availability of electronic resources for the…

  20. Electron backscatter diffraction as a useful method for alloys microstructure characterization

    Energy Technology Data Exchange (ETDEWEB)

    Klimek, Leszek; Pietrzyk, Bozena

    2004-11-17

    Microstructure examination of cast Co-Cr-Mo alloy is presented in this paper. The surface morphology and chemical composition of the alloy were investigated by means of scanning electron microscopy (SEM) and energy dispersive X-ray microanalysis (EDX). An identification of alloy phases was carried out using electron backscatter diffraction (EBSD). Two different kinds of precipitates in metallic matrix were found. They were identified as MC and M{sub 23}C{sub 6} type of carbides in Co-lattice solid solution. The advantages and limits of the EBSD method are described. It is presented that EBSD, as excellent tool for phase identification, is a valuable supplementary method for materials research.

  1. Handling of biological specimens for electron microscopy

    International Nuclear Information System (INIS)

    Bullock, G.

    1987-01-01

    There are many different aspects of specimen preparation procedure which need to be considered in order to achieve good results. Whether using the scanning or transmission microscope, the initial handling procedures are very similar and are selected for the information required. Handling procedures and techniques described are: structural preservation; immuno-and histo-chemistry; x-ray microanalysis and autoradiography; dehydration and embedding; mounting and coating specimens for scanning electron microscopy; and sectioning of resin embedded material. With attention to detail and careful choice of the best available technique, excellent results should be obtainable whatever the specimen. 6 refs

  2. A systematic review of portable electronic technology for health education in resource-limited settings.

    Science.gov (United States)

    McHenry, Megan S; Fischer, Lydia J; Chun, Yeona; Vreeman, Rachel C

    2017-08-01

    The objective of this study is to conduct a systematic review of the literature of how portable electronic technologies with offline functionality are perceived and used to provide health education in resource-limited settings. Three reviewers evaluated articles and performed a bibliography search to identify studies describing health education delivered by portable electronic device with offline functionality in low- or middle-income countries. Data extracted included: study population; study design and type of analysis; type of technology used; method of use; setting of technology use; impact on caregivers, patients, or overall health outcomes; and reported limitations. Searches yielded 5514 unique titles. Out of 75 critically reviewed full-text articles, 10 met inclusion criteria. Study locations included Botswana, Peru, Kenya, Thailand, Nigeria, India, Ghana, and Tanzania. Topics addressed included: development of healthcare worker training modules, clinical decision support tools, patient education tools, perceptions and usability of portable electronic technology, and comparisons of technologies and/or mobile applications. Studies primarily looked at the assessment of developed educational modules on trainee health knowledge, perceptions and usability of technology, and comparisons of technologies. Overall, studies reported positive results for portable electronic device-based health education, frequently reporting increased provider/patient knowledge, improved patient outcomes in both quality of care and management, increased provider comfort level with technology, and an environment characterized by increased levels of technology-based, informal learning situations. Negative assessments included high investment costs, lack of technical support, and fear of device theft. While the research is limited, portable electronic educational resources present promising avenues to increase access to effective health education in resource-limited settings, contingent

  3. SAGES: a suite of freely-available software tools for electronic disease surveillance in resource-limited settings.

    Directory of Open Access Journals (Sweden)

    Sheri L Lewis

    Full Text Available Public health surveillance is undergoing a revolution driven by advances in the field of information technology. Many countries have experienced vast improvements in the collection, ingestion, analysis, visualization, and dissemination of public health data. Resource-limited countries have lagged behind due to challenges in information technology infrastructure, public health resources, and the costs of proprietary software. The Suite for Automated Global Electronic bioSurveillance (SAGES is a collection of modular, flexible, freely-available software tools for electronic disease surveillance in resource-limited settings. One or more SAGES tools may be used in concert with existing surveillance applications or the SAGES tools may be used en masse for an end-to-end biosurveillance capability. This flexibility allows for the development of an inexpensive, customized, and sustainable disease surveillance system. The ability to rapidly assess anomalous disease activity may lead to more efficient use of limited resources and better compliance with World Health Organization International Health Regulations.

  4. Use and Cost of Electronic Resources in Central Library of Ferdowsi University Based on E-metrics

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Davarpanah

    2012-07-01

    Full Text Available The purpose of this study was to investigate the usage of electronic journals in Ferdowsi University, Iran based on e-metrics. The paper also aimed to emphasize the analysis of cost-benefit and the correlation between the journal impact factors and the usage data. In this study experiences of Ferdowsi University library on licensing and usage of electronic resources was evaluated by providing a cost-benefit analysis based on the cost and usage statistics of electronic resources. Vendor-provided data were also compared with local usage data. The usage data were collected by tracking web-based access locally, and by collecting vender-provided usage data. The data sources were one-year of vendor-supplied e-resource usage data such as Ebsco, Elsevier, Proquest, Emerald, Oxford and Springer and local usage data collected from the Ferdowsi university web server. The study found that actual usage values differ for vendor-provided data and local usage data. Elsevier has got the highest usage degree in searches, sessions and downloads. Statistics also showed that a small number of journals satisfy significant amount of use while the majority of journals were used less frequent and some were never used at all. The users preferred the PDF rather than HTML format. The data in subject profile suggested that the provided e-resources were best suited to certain subjects. There was no correlation between IF and electronic journal use. Monitoring the usage of e-resources gained increasing importance for acquisition policy and budget decisions. The article provided information about local metrics for the six surveyed vendors/publishers, e.g. usage trends, requests per package, cost per use as related to the scientific specialty of the university.

  5. Building and Managing Electronic Resources in Digital Era in India with Special Reference to IUCAA and NIV, Pune: A Comparative Case Study

    Science.gov (United States)

    Sahu, H. K.; Singh, S. N.

    2015-04-01

    This paper discusses and presents a comparative case study of two libraries in Pune, India, Inter-University Centre for Astronomy and Astrophysics and Information Centre and Library of National Institute of Virology (Indian Council of Medical Research). It compares how both libraries have managed their e-resource collections, including acquisitions, subscriptions, and consortia arrangements, while also developing a collection of their own resources, including pre-prints and publications, video lectures, and other materials in an institutional repository. This study illustrates how difficult it is to manage electronic resources in a developing country like India, even though electronic resources are used more than print resources. Electronic resource management can be daunting, but with a systematic approach, various problems can be solved, and use of the materials will be enhanced.

  6. Evolutionary developments in x ray and electron energy loss microanalysis instrumentation for the analytical electron microscope

    Science.gov (United States)

    Zaluzec, Nester J.

    Developments in instrumentation for both X ray Dispersive and Electron Energy Loss Spectroscopy (XEDS/EELS) over the last ten years have given the experimentalist a greatly enhanced set of analytical tools for characterization. Microanalysts have waited for nearly two decades now in the hope of getting a true analytical microscope and the development of 300 to 400 kV instruments should have allowed us to attain this goal. Unfortunately, this has not generally been the case. While there have been some major improvements in the techniques, there has also been some devolution in the modern AEM (Analytical Electron Microscope). In XEDS, the majority of today's instruments are still plagued by the hole count effect, which was first described in detail over fifteen years ago. The magnitude of this problem can still reach the 20 percent level for medium atomic number species in a conventional off-the-shelf intermediate voltage AEM. This is an absurd situation and the manufacturers should be severely criticized. Part of the blame, however, also rests on the AEM community for not having come up with a universally agreed upon standard test procedure. Fortunately, such a test procedure is in the early stages of refinement. The proposed test specimen consists of an evaporated Cr film approx. 500 to 1000A thick supported upon a 3mm diameter Molybdenum 200 micron aperture.

  7. Tyrosinase inhibitor screening in traditional Chinese medicines by electrophoretically mediated microanalysis.

    Science.gov (United States)

    Tang, Lilin; Zhang, Wenpeng; Zhao, Haiyan; Chen, Zilin

    2015-08-01

    A capillary-electrophoresis-based method for the screening of tyrosinase inhibitors in traditional Chinese medicines was developed. The method integrated electrophoretically mediated microanalysis with sandwich mode injection, partial filling, and rapid polarity switching techniques, and carried out on-column enzyme reaction and the separation of substrate and product. The conditions were optimized including the background electrolyte, mixing voltage, and the incubation time. Finally, the screening of nine standard natural compounds of traditional Chinese medicines was carried out. The inhibitors can be directly identified from the reduced peak area of the product compared to that obtained without any inhibitor. Chlorogenic acid (100 μM) showed inhibitory activity with the inhibitory percentage of 19.8%, while the other compounds showed no inhibitory activity. This method has great application potential in drug discovery from traditional Chinese medicines. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Electron microscopy study of the microstructure of Ni–W substrate surface

    Energy Technology Data Exchange (ETDEWEB)

    Ovcharov, A. V.; Karateev, I. A.; Mikhutkin, A. A. [National Research Centre “Kurchatov Institute,” (Russian Federation); Orekhov, A. S. [Russian Academy of Sciences, Shubnikov Institute of Crystallography, Federal Scientific Research Centre “Crystallography and Photonics,” (Russian Federation); Presniakov, M. Yu.; Chernykh, I. A.; Zanaveskin, M. L.; Kovalchuk, M. V.; Vasiliev, A. L., E-mail: a.vasiliev56@gmail.com [National Research Centre “Kurchatov Institute,” (Russian Federation)

    2016-11-15

    The surface microstructure of Ni–W alloy tapes, which are used as substrates to form films of high-temperature superconductors and photovoltaic devices, has been studied. Several samples of a Ni{sub 95}W{sub 5} tape (Evico) annealed under different conditions were analyzed using scanning electron microscopy, energy-dispersive X-ray microanalysis, electron diffraction, and electron energy-loss spectroscopy. NiWO{sub 4} precipitates are found on the surface of annealed samples. The growth of precipitates at a temperature of 950°C is accompanied by the formation of pores on the surface or under an oxide film. Depressions with a wedge-shaped profile are found at the grain boundaries. Annealing in a reducing atmosphere using a specially prepared chamber allows one to form a surface free of nickel tungstate precipitates.

  9. Diamond exploration and mantle structure imaging using PIXE microanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, C G; Griffin, W L; Win, T T [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1997-12-31

    Geochemical methods of diamond exploration rely on recognizing indicator minerals that formed in the earth`s upper mantle, within the diamond stability field, and were entrained in rapidly rising volatile-rich magmas and emplaced in or on the crust. Diamond is only stable at high pressure. Therefore, diamond exploration commonly targets prospects containing high pressure minerals, such as low-Ca, high-Cr (`G10`) garnets and high-Cr chromites, similar to inclusions in diamonds. However, this procedure can be ambiguous; some barren pipes contain abundant `G10` garnets. while such garnets are extremely rare in the Argyle pipe, the world`s largest diamond producer. Similarly, high-Cr chromites are shed by a wide variety of barren rock types. PIXE microanalysis of trace elements in concentrate garnets and chromites from kimberlites and other volcanic rocks helps to remove the ambiguities by pinning down the source temperature (T), pressure (P) and local (paleo)geotherm (P-T relation), which permits the rich store of trace element information in these minerals, reflecting rock chemistry and metasomatic processes, to be placed in a stratigraphic context. 11 refs., 4 figs.

  10. Diamond exploration and mantle structure imaging using PIXE microanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, C.G.; Griffin, W.L.; Win, T.T. [Commonwealth Scientific and Industrial Research Organisation (CSIRO), North Ryde, NSW (Australia). Div. of Exploration Geoscience

    1996-12-31

    Geochemical methods of diamond exploration rely on recognizing indicator minerals that formed in the earth`s upper mantle, within the diamond stability field, and were entrained in rapidly rising volatile-rich magmas and emplaced in or on the crust. Diamond is only stable at high pressure. Therefore, diamond exploration commonly targets prospects containing high pressure minerals, such as low-Ca, high-Cr (`G10`) garnets and high-Cr chromites, similar to inclusions in diamonds. However, this procedure can be ambiguous; some barren pipes contain abundant `G10` garnets. while such garnets are extremely rare in the Argyle pipe, the world`s largest diamond producer. Similarly, high-Cr chromites are shed by a wide variety of barren rock types. PIXE microanalysis of trace elements in concentrate garnets and chromites from kimberlites and other volcanic rocks helps to remove the ambiguities by pinning down the source temperature (T), pressure (P) and local (paleo)geotherm (P-T relation), which permits the rich store of trace element information in these minerals, reflecting rock chemistry and metasomatic processes, to be placed in a stratigraphic context. 11 refs., 4 figs.

  11. [Use of internet and electronic resources among Spanish intensivist physicians. First national survey].

    Science.gov (United States)

    Gómez-Tello, V; Latour-Pérez, J; Añón Elizalde, J M; Palencia-Herrejón, E; Díaz-Alersi, R; De Lucas-García, N

    2006-01-01

    Estimate knowledge and use habits of different electronic resources in a sample of Spanish intensivists: Internet, E-mail, distribution lists, and use of portable electronic devices. Self-applied questionnaire. A 50-question questionnaire was distributed among Spanish intensivists through the hospital marketing delegates of a pharmaceutical company and of electronic forums. A total of 682 questionnaires were analyzed (participation: 74%). Ninety six percent of those surveyed used Internet individually: 67% admitted training gap. Internet was the second source of clinical consultations most used (61%), slightly behind consultation to colleagues (65%). The pages consulted most were bibliographic databases (65%) and electronic professional journals (63%), with limited use of Evidence Based Medicine pages (19%). Ninety percent of those surveyed used e-mail regularly in the practice of their profession, although 25% admitted that were not aware of its possibilities. The use of E-mail decreased significantly with increase in age. A total of 62% of the intensivists used distribution lists. Of the rest, 42% were not aware of its existence and 32% admitted they had insufficient training to handle them. Twenty percent of those surveyed had portable electronic devices and 64% considered it useful, basically due to its rapid consultation at bedside. Female gender was a negative predictive factor of its use (OR 0.35; 95% CI 0.2-0.63; p=0.0002). A large majority of the Spanish intensivists use Internet and E-mail. E-mail lists and use of portable devices are still underused resources. There are important gaps in training and infrequent use of essential pages. There are specific groups that require directed educational policies.

  12. Model of e-learning with electronic educational resources of new generation

    OpenAIRE

    A. V. Loban; D. A. Lovtsov

    2017-01-01

    Purpose of the article: improving of scientific and methodical base of the theory of the е-learning of variability. Methods used: conceptual and logical modeling of the е-learning of variability process with electronic educational resource of new generation and system analysis of the interconnection of the studied subject area, methods, didactics approaches and information and communication technologies means. Results: the formalization complex model of the е-learning of variability with elec...

  13. Prospects of X-ray microanalysis in the study of pathophysiology of myocardial contraction

    International Nuclear Information System (INIS)

    Wendt-Gallitelli, M.F.; Schwegler, M.; Holubarsch, C.; Jacob, R.; Wolburg, H.; Schlote, W.

    1980-01-01

    X-ray microanalysis was used to compare chemically untreated cryosections of quick-frozen myocardial tissue in 'caffeine contracture' with cryosections of normal muscle. Our goal was to find out if it is possible by this method to detect changes in the calcium compartmentalization of the myocardial cell occurring by changes in its functional state. While it is possible to quantitate calcium in the cisternae of sarcoplasmic reticulum of the control muscle preparation, calcium could never be detected in these compartments of caffeine-contracted muscles. In active microsomal fraction of ventricular myocardium it is possible to quantitate calcium and also to distinguish two components on account of their different ability to accumulate this element. The calcium content is different in the two components of the fraction. (orig.) [de

  14. Impact of Knowledge Resources Linked to an Electronic Health Record on Frequency of Unnecessary Tests and Treatments

    Science.gov (United States)

    Goodman, Kenneth; Grad, Roland; Pluye, Pierre; Nowacki, Amy; Hickner, John

    2012-01-01

    Introduction: Electronic knowledge resources have the potential to rapidly provide answers to clinicians' questions. We sought to determine clinicians' reasons for searching these resources, the rate of finding relevant information, and the perceived clinical impact of the information they retrieved. Methods: We asked general internists, family…

  15. The lack of age-pigments and the alterations in intracellular monovalent electrolytes in spontaneously hypertensive, stroke-prone (SHRsp) rats as revealed by electron microscopy and X-ray microanalysis

    International Nuclear Information System (INIS)

    Nagy, I.; Nagy, V.; Casoli, T.; Lustyik, G.

    1989-01-01

    Male, spontaneously hypertensive, stroke-prone (SHRsp) rats established by Okamoto et al. were studied. About 80% of the males of this strain have a particularly short life span (33-41 weeks); they display a considerable hypertension (above 220 mmHg) and a tendency for plurifocal brain strokes. Hypertension and strokes can be provoked in an accelerated and synchronized fashion by supplementing 1% NaCl into their drinking water. Symptoms of the appearance of brain strokes can be judged from characteristic signs of motor disorders, and can be established also by pathohistology. Since hypertension and arteriosclerosis are frequently involved in aging, the question we intended to answer was whether these animals may represent a model of the normal aging process or not. Two approaches are described: (1) Accumulation of lipofuscin granules in their brain, liver and myocardium was followed by transmission electron microscopy before and after the appearance of strokes. It has been established that these tissues do not show any typical accumulation of lipofuscin granules, although submicroscopic signs of an enhanced damage of cell organelles (especially of mitochondria in liver and brain cells, but not in myocardium) were encountered. (2) The intracellular monovalent composition in the brain and liver was measured by using bulk-specimen X-ray microanalysis. The intracellular Na-content (mEq/kg water) was significantly higher (170-200%) in both the brain and liver cells, whereas the K-content increased only moderately (118-130%). The results suggest that although the SHRsp rats do not represent a direct model for the normal aging process from the point of view of lipofuscin accumulation, the shifts of the monovalent electrolyte contents in the brain and liver cells observed already in the youngest ages, are similar to those observed in aged normal rats

  16. Electronic Document Management: A Human Resource Management Case Study

    Directory of Open Access Journals (Sweden)

    Thomas Groenewald

    2004-11-01

    Full Text Available This case study serve as exemplar regarding what can go wrong with the implementation of an electronic document management system. Knowledge agility and knowledge as capital, is outlined against the backdrop of the information society and knowledge economy. The importance of electronic document management and control is sketched thereafter. The literature review is concluded with the impact of human resource management on knowledge agility, which includes references to the learning organisation and complexity theory. The intervention methodology, comprising three phases, follows next. The results of the three phases are presented thereafter. Partial success has been achieved with improving the human efficacy of electronic document management, however the client opted to discontinue the system in use. Opsomming Die gevalle studie dien as voorbeeld van wat kan verkeerd loop met die implementering van ’n elektroniese dokumentbestuur sisteem. Teen die agtergrond van die inligtingsgemeenskap en kennishuishouding word kennissoepelheid en kennis as kapitaal bespreek. Die literatuurstudie word afgesluit met die inpak van menslikehulpbronbestuur op kennissoepelheid, wat ook die verwysings na die leerorganisasie en kompleksietydsteorie insluit. Die metodologie van die intervensie, wat uit drie fases bestaan, volg daarna. Die resultate van die drie fases word vervolgens aangebied. Slegs gedeelte welslae is behaal met die verbetering van die menslike doeltreffendheid ten opsigte van elektroniese dokumentbestuur. Die klient besluit egter om nie voort te gaan om die huidige sisteem te gebruik nie.

  17. Challenges in the implementation of an electronic surveillance system in a resource-limited setting: Alerta, in Peru

    Directory of Open Access Journals (Sweden)

    Soto Giselle

    2008-11-01

    Full Text Available Abstract Background Infectious disease surveillance is a primary public health function in resource-limited settings. In 2003, an electronic disease surveillance system (Alerta was established in the Peruvian Navy with support from the U.S. Naval Medical Research Center Detachment (NMRCD. Many challenges arose during the implementation process, and a variety of solutions were applied. The purpose of this paper is to identify and discuss these issues. Methods This is a retrospective description of the Alerta implementation. After a thoughtful evaluation according to the Centers for Disease Control and Prevention (CDC guidelines, the main challenges to implementation were identified and solutions were devised in the context of a resource-limited setting, Peru. Results After four years of operation, we have identified a number of challenges in implementing and operating this electronic disease surveillance system. These can be divided into the following categories: (1 issues with personnel and stakeholders; (2 issues with resources in a developing setting; (3 issues with processes involved in the collection of data and operation of the system; and (4 issues with organization at the central hub. Some of the challenges are unique to resource-limited settings, but many are applicable for any surveillance system. For each of these challenges, we developed feasible solutions that are discussed. Conclusion There are many challenges to overcome when implementing an electronic disease surveillance system, not only related to technology issues. A comprehensive approach is required for success, including: technical support, personnel management, effective training, and cultural sensitivity in order to assure the effective deployment of an electronic disease surveillance system.

  18. The electron microscopy facility at the LNLS

    International Nuclear Information System (INIS)

    Ugarte, D.; Zanchet, D.; Silva, P.C.; Araujo, S.R. de; Bettini, J.; Gonzalez, J.C.; Nakabayashi, D.B.

    2004-01-01

    Full text: The Electron Microscopy Laboratory (LME, Lab. Microscopia Eletronica) is one of the multi user facilities of the Laboratorio Nacional de Luz Sincrotron (LNLS). It has been in operation since the beginning of 1999 to provide spatial high resolution tools, making the LNLS a unique center for advanced characterization of materials. The equipment installed at the LME can be brie y described as: a) a Low Vacuum Scanning Electron Microscope (SEM, JSM-5900LV) with microanalysis and crystallographic mapping capabilities; b) a Field Emission Gun SEM (JSM-6330F); c) a 300 kV High Resolution Transmission Electron Microscope (HRTEM, JEM 3010 URP, 1.7 A Point Res.) with TV Camera, Multi-Scan CCD Camera and X-ray Si(Li) detector; and d) a complete sample preparation laboratory for EM studies A simple procedure allows access to the LME instruments, firstly a short research project must be submitted for evaluation of viability and relevance; subsequently the training microscope sessions are scheduled. It is important to remark that EM is a routine characterization tool and the researchers have to operate the microscope by themselves; for that a training period is necessary, which may vary from 1-2 weeks for a SEM to 2-4 months for the HRTEM. Our staff addresses a great effort to the formation of human resources in order to allow inexperienced Users to become capable of acquiring and interpreting data for their research projects. Since its installation, the LME has trained more than 300 Users in EM techniques. In 2003, the number of projects developed was: 36 in the HRTEM, 16 in the FEG-SEM and 48 in the LV-SEM. This means that just the HRTEM has operated 2157 hours. The constant increase of users in addition to the more exigent EM studies being proposed indicates the necessity of an expansion of the LME by the purchase of a 200 kV FEG-TEM oriented for nano-analysis and Electron Energy Loss Spectroscopy.. (author)

  19. Single-particle characterization of summertime Antarctic aerosols collected at King George Island using quantitative energy-dispersive electron probe X-ray microanalysis and attenuated total reflection Fourier transform-infrared imaging techniques.

    Science.gov (United States)

    Maskey, Shila; Geng, Hong; Song, Young-Chul; Hwang, Heejin; Yoon, Young-Jun; Ahn, Kang-Ho; Ro, Chul-Un

    2011-08-01

    Single-particle characterization of Antarctic aerosols was performed to investigate the impact of marine biogenic sulfur species on the chemical compositions of sea-salt aerosols in the polar atmosphere. Quantitative energy-dispersive electron probe X-ray microanalysis was used to characterize 2900 individual particles in 10 sets of aerosol samples collected between March 12 and 16, 2009 at King Sejong Station, a Korean scientific research station located at King George Island in the Antarctic. Two size modes of particles, i.e., PM(2.5-10) and PM(1.0-2.5), were analyzed, and four types of particles were identified, with sulfur-containing sea-salt particles being the most abundant, followed by genuine sea-salt particles without sulfur species, iron-containing particles, and other species including CaCO(3)/CaMg(CO(3))(2), organic carbon, and aluminosilicates. When a sulfur-containing sea-salt particle showed an atomic concentration ratio of sulfur to sodium of >0.083 (seawater ratio), it is regarded as containing nonsea-salt sulfate (nss-SO(4)(2-)) and/or methanesulfonate (CH(3)SO(3)(-)), which was supported by attenuated total reflection Fourier transform-infrared imaging measurements. These internal mixture particles of sea-salt/CH(3)SO(3)(-)/SO(4)(2-) were very frequently encountered. As nitrate-containing particles were not encountered, and the air-masses for all of the samples originated from the Pacific Ocean (based on 5-day backward trajectories), the oxidation of dimethylsulfide (DMS) emitted from phytoplanktons in the ocean is most likely to be responsible for the formation of the mixed sea-salt/CH(3)SO(3)(-)/SO(4)(2-) particles.

  20. Considering Point-of-Care Electronic Medical Resources in Lieu of Traditional Textbooks for Medical Education.

    Science.gov (United States)

    Hale, LaDonna S; Wallace, Michelle M; Adams, Courtney R; Kaufman, Michelle L; Snyder, Courtney L

    2015-09-01

    Selecting resources to support didactic courses is a critical decision, and the advantages and disadvantages must be carefully considered. During clinical rotations, students not only need to possess strong background knowledge but also are expected to be proficient with the same evidence-based POC resources used by clinicians. Students place high value on “real world” learning and therefore may place more value on POC resources that they know practicing clinicians use as compared with medical textbooks. The condensed nature of PA education requires students to develop background knowledge and information literacy skills over a short period. One way to build that knowledge and those skills simultaneously is to use POC resources in lieu of traditional medical textbooks during didactic training. Electronic POC resources offer several advantages over traditional textbooks and should be considered as viable options in PA education.

  1. Emission sources in scanning electron microscopy

    International Nuclear Information System (INIS)

    Malkusch, W.

    1990-01-01

    Since the beginning of the commercial scanning electron microscopy, there are two kinds of emission sources generally used for generation of the electron beam. The first group covers the cathodes heated directly and indirectly (tungsten hair-needle cathodes and lanthanum hexaboride single crystals, LaB 6 cathode). The other group is the field emission cathodes. The advantages of the thermal sources are their low vacuum requirement and their high beam current which is necessary for the application of microanalysis units. Disadvantages are the short life and the low resolution. Advantages of the field emission cathode unambiguously are the possibilities of the very high resolution, especially in the case of low acceleration voltages. Disadvantages are the necessary ultra-high vacuum and the low beam current. An alternative source is the thermally induced ZrO/W field emission cathode which works stably as compared to the cold field emission and does not need periodic flashing for emitter tip cleaning. (orig.) [de

  2. Resource conservation approached with an appropriate collection and upgrade-remanufacturing for used electronic products.

    Science.gov (United States)

    Zlamparet, Gabriel I; Tan, Quanyin; Stevels, A B; Li, Jinhui

    2018-03-01

    This comparative research represents an example for a better conservation of resources by reducing the amount of waste (kg) and providing it more value under the umbrella of remanufacturing. The three discussed cases will expose three issues already addressed separately in the literature. The generation of waste electrical and electronic equipment (WEEE) interacts with the environmental depletion. In this article, we gave the examples of addressed issues under the concept of remanufacturing. Online collection opportunity eliminating classical collection, a business to business (B2B) implementation for remanufactured servers and medical devices. The material reuse (recycling), component sustainability, reuse (part harvesting), product reuse (after repair/remanufacturing) indicates the recovery potential using remanufacturing tool for a better conservation of resources adding more value to the products. Our findings can provide an overview of new system organization for the general collection, market potential and the technological advantages using remanufacturing instead of recycling of WEEE or used electrical and electronic equipment. Copyright © 2017. Published by Elsevier Ltd.

  3. Use of scanning electron microscopy and microanalysis to determine chloride content of concrete and raw materials.

    Science.gov (United States)

    2013-02-01

    Standard sample sets of cement and mortar formulations with known levels of Cl as well as concrete samples subject to Cl diffusion were all prepared for and analyzed with scanning electron microscopy (SEM) and electron microprobe (EPMA). Using x-ray ...

  4. Effects of the Use of Electronic Human Resource Management (EHRM Within Human Resource Management (HRM Functions at Universities

    Directory of Open Access Journals (Sweden)

    Chux Gervase Iwu

    2016-09-01

    Full Text Available This study set out to examine the effect of e-hrm systems in assisting human resource practitioners to execute their duties and responsibilities. In comparison to developed economies of the world, information technology adoption in sub-Saharan Africa has not been without certain glitches. Some of the factors that are responsible for these include poor need identification, sustainable funding, and insufficient skills. Besides these factors, there is also the issue of change management and users sticking to what they already know. Although, the above factors seem negative, there is strong evidence that information systems such as electronic human resource management present benefits to an organization. To achieve this, a dual research approach was utilized. Literature assisted immensely in both the development of the conceptual framework upon which the study hinged as well as in the development of the questionnaire items. The study also made use of an interview checklist to guide the participants. The findings reveal a mix of responses that indicate that while there are gains in adopting e-hrm systems, it is wiser to consider supporting resources as well as articulate the needs of the university better before any investment is made.

  5. Electronic human resource management: Enhancing or entrancing?

    Directory of Open Access Journals (Sweden)

    Paul Poisat

    2017-07-01

    Full Text Available Orientation: This article provides an investigation into the current level of development of the body of knowledge related to electronic human resource management (e-HRM by means of a qualitative content analysis. Several aspects of e-HRM, namely definitions of e-HRM, the theoretical perspectives around e-HRM, the role of e-HRM, the various types of e-HRM and the requirements for successful e-HRM, are examined. Research purpose: The purpose of the article was to determine the status of e-HRM and examine the studies that report on the link between e-HRM and organisational productivity. Motivation for the study: e-HRM has the capacity to improve organisational efficiency and leverage the role of human resources (HR as a strategic business partner. Main findings: The notion that the implementation of e-HRM will lead to improved organisational productivity is commonly assumed; however, empirical evidence in this regard was found to be limited. Practical/managerial implications: From the results of this investigation it is evident that more research is required to gain a greater understanding of the influence of e-HRM on organisational productivity, as well as to develop measures for assessing this influence. Contribution: This article proposes additional areas to research and measure when investigating the effectiveness of e-HRM. It provides a different lens from which to view e-HRM assessment whilst keeping it within recognised HR measurement parameters (the HR value chain. In addition, it not only provides areas for measuring e-HRM’s influence but also provides important clues as to how the measurements may be approached.

  6. Sweat gland toxicity induced by bis (tributyltin) oxide: an ultrastructural and X-ray microanalysis study

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, O. [Univ. of Occupational and Environmental Health Japan, Kitakyushu (Japan). Dept. of Dermatology and Occupational Dermatopathology; Doi, Y.; Kudo, H.; Fujimoto, S. [Univ. of Occupational and Environmental Health Japan, Kitakyushu (Japan). Dept. of Anatomy; Yoshizuka, M. [Kurume Univ. (Japan). Dept. of Anatomy

    2000-12-01

    Acute toxicity of bis (tributyltin) oxide in the sweat glands in the rat footpad was investigated by electron microscopy and an energy-dispersive X-ray microanalyzer. Male Wistar rats received an intramuscular injection of 0.5 ml/kg bis (tributyltin) oxide. After 6-8 h, swelling of mitochondria appeared in the secretory cells of the sweat glands. After 12 h, the secretory cells began to show intracytoplasmic edema. After 16-20 h, secretory cells in some sweat glands showed marked hydropic degeneration with swollen cytoplasm. Using X-ray microanalysis, tin peaks were preferentially obtained from the swollen mitochondria of the affected secretory cells. Mitochondria dysfunction due to the toxic effects of bis (tributyltin) oxide induced changes in the secretory cells of rat sweat glands contained three types of cells: degenerating dark cells, regenerating cells carrying injured mitochondria, and light cells which were morphologically very similar to the cells in the transitional portion of the sweat gland. These light cells appeared to differentiate into active secretory cells after settling down in the secretory portion. Based on these observations, we concluded that the cells in the transitional portion could play an important role at least as reserve cells against secretory cell toxicity. In association with the regenerating process of the damaged secretory portions, increased mitotic activities were seen in different areas of all the dermal sweat ducts. The above-mentioned morphological observations for cell damage and subsequent regeneration and renewal of secretory cells in sweat gland intoxication have not been reported so far. (orig.)

  7. PREFACE: 22nd International Congress on X-Ray Optics and Microanalysis

    Science.gov (United States)

    Falkenberg, Gerald; Schroer, Christian G.

    2014-04-01

    ICXOM22 The 22nd edition of the International Congress on X-ray Optics and Microanalysis (ICXOM 22) was held from 2-6 September 2013, in Hamburg, Germany. The congress was organized by scientists from DESY in collaboration with TU Dresden and Helmholtz-Zentrum Geesthacht, who also formed the scientific advisory board. The congress was hosted in the historical lecture hall building of the University of Hamburg located in the city center. ICXOM22 was attended by about 210 registered participants, including 67 students, and was open for listeners. The attendance was split between 26 countries (Germany 120, rest of Europe 57, America 20, Asia 8, Australia 6). The ICXOM series is a forum for the discussion of new developments in instrumentation, methods and applications in the fields of micro- and nano-analysis by means of X-ray beams. Following the trend of the last 10 years, the conference focusses more and more on synchrotron radiation rather than X-ray laboratory sources. Besides micro-beam X-ray fluorescence and absorption spectroscopy, different methods based on diffraction and full-field imaging were covered. Newly introduced to the ICXOM series was scanning coherent X-ray diffraction imaging, which was shown to evolve into a mature method for the imaging of nanostructures, defects and strain fields. New developments on fast X-ray detectors were discussed (Lambda, Maia) and advances in X-ray optics — like the generation of a sub 5nm point focus by Multilayer Zone plates — were presented. Talks on micro- and nano-analysis applications were distributed in special sessions on bio-imaging, Earth and environmental sciences, and Cultural heritage. The congress featured nine keynote and ten plenary talks, 56 talks in 14 parallel sessions and about 120 posters in three afternoon sessions. Seventeen commercial exhibitors exposed related X-ray instrumentation products, and two luncheon seminars on detector electronics were given. This allowed us to keep the student

  8. Use of radioisotopes in the electronic industry

    International Nuclear Information System (INIS)

    Walis, L.; Jaskolska, H.; Wronski, W.; Stverak, B.

    1976-01-01

    The possibilities of applying nuclear methods in the study of high purity materials and of special technologies used in the electronic industry are described. Attention is paid to neutron activation analysis, nuclear microanalysis of thin surface layers, autoradiography and to radiotracer techniques. The most efficient applications of nuclear methods are indicated, such as the purification of materials to semiconductor grade, doping of semiconductor materials by metallurgical techniques or by diffusion and implantation, investigations of the effect of material processing on the surface purity, studies of metal-semiconductor reactions, dielectric layers, etc. The advantages and disadvantages of the described methods and their sensitivities are discussed. Examples of practical work done so far are given. (author)

  9. Identifying and evaluating electronic learning resources for use in adult-gerontology nurse practitioner education.

    Science.gov (United States)

    Thompson, Hilaire J; Belza, Basia; Baker, Margaret; Christianson, Phyllis; Doorenbos, Ardith; Nguyen, Huong

    2014-01-01

    Enhancing existing curricula to meet newly published adult-gerontology advanced practice registered nurse (APRN) competencies in an efficient manner presents a challenge to nurse educators. Incorporating shared, published electronic learning resources (ELRs) in existing or new courses may be appropriate in order to assist students in achieving competencies. The purposes of this project were to (a) identify relevant available ELR for use in enhancing geriatric APRN education and (b) to evaluate the educational utility of identified ELRs based on established criteria. A multilevel search strategy was used. Two independent team members reviewed identified ELR against established criteria to ensure utility. Only resources meeting all criteria were retained. Resources were found for each of the competency areas and included formats such as podcasts, Web casts, case studies, and teaching videos. In many cases, resources were identified using supplemental strategies and not through traditional search or search of existing geriatric repositories. Resources identified have been useful to advanced practice educators in improving lecture and seminar content in a particular topic area and providing students and preceptors with additional self-learning resources. Addressing sustainability within geriatric APRN education is critical for sharing of best practices among educators and for sustainability of teaching and related resources. © 2014.

  10. Systematic review of electronic surveillance of infectious diseases with emphasis on antimicrobial resistance surveillance in resource-limited settings.

    Science.gov (United States)

    Rattanaumpawan, Pinyo; Boonyasiri, Adhiratha; Vong, Sirenda; Thamlikitkul, Visanu

    2018-02-01

    Electronic surveillance of infectious diseases involves rapidly collecting, collating, and analyzing vast amounts of data from interrelated multiple databases. Although many developed countries have invested in electronic surveillance for infectious diseases, the system still presents a challenge for resource-limited health care settings. We conducted a systematic review by performing a comprehensive literature search on MEDLINE (January 2000-December 2015) to identify studies relevant to electronic surveillance of infectious diseases. Study characteristics and results were extracted and systematically reviewed by 3 infectious disease physicians. A total of 110 studies were included. Most surveillance systems were developed and implemented in high-income countries; less than one-quarter were conducted in low-or middle-income countries. Information technologies can be used to facilitate the process of obtaining laboratory, clinical, and pharmacologic data for the surveillance of infectious diseases, including antimicrobial resistance (AMR) infections. These novel systems require greater resources; however, we found that using electronic surveillance systems could result in shorter times to detect targeted infectious diseases and improvement of data collection. This study highlights a lack of resources in areas where an effective, rapid surveillance system is most needed. The availability of information technology for the electronic surveillance of infectious diseases, including AMR infections, will facilitate the prevention and containment of such emerging infectious diseases. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  11. From Millennium ERM to Proquest 360 Resource Manager: Implementing a new Electronic Resources Management System ERMS in an International Graduate Research University in Saudi Arabia

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    An overview of the Recommendation Study and the subsequent Implementation of a new Electronic Resources Management system ERMS in an international graduate research university in the Kingdom of Saudi Arabia. It covers the timeline, deliverables

  12. Electron microscopy (nonbiological)

    International Nuclear Information System (INIS)

    Cowley, J.M.

    1986-01-01

    The period 1982-1985, which is covered by this review, has seen major advances in the capabilities of the commercially available instruments. The new electron microscopes operating in the range of 300-400 keV have provided important improvements in the resolution available and in the possibilities for microanalysis of very small specimen areas. Correspondingly there has been a broadening in the range of possible applications of the techniques. Electron microscopy has become a much more powerful tool for studies of semiconductors and catalysts, for example, and offers promise of a major revolution in surface science. The major industrial laboratories, in particular, are investing in million-dollar instruments and in the highly skilled scientists needed to run them because the capabilities of the new instruments are seen to have immediate practical applications to current industrial research. Unfortunately all of the new instruments and most of the skilled users come from overseas. The American instrument industry, although showing some limited signs of life, is not yet in a position to compete in this lucrative market and the training of electron optics specialists in this country is far from meeting the demand. The increased sophistication required for both the operation of the instruments and the interpretation of the observation requires that the quality as well as the quantity of trainees must be improved. 62 references

  13. X ray microanalysis of leaf and seed elemental composition among four species of living fossil gymnosperm

    International Nuclear Information System (INIS)

    Chang Chongyan; Li Yongliang; Chen Xiaoduan; Liu Jinying; Zhou Yunlong

    2002-01-01

    The leaf and seed elemental composition and average mass fraction are analysed or four species of living fossil gymnosperm: Ginkgo biloba L., Cathaya argyrophylla Chun et Kuang, Glyptostrobus pensilis (D. Don) Koch and Metasequoia glyptostroboides Hu et Cheng by SEM X ray microanalysis method. The results show that the elemental composition is different and the elemental average mass fraction is evidently different between the seed and leaf for the same species. The elemental composition and average mass fraction between seed and seed wing is different in Cathaya argyrophylla and Metasequoia glyptostroboides. Among three type leaf of Glyptostrobus pensilis, the elemental composition is the same, but average mass fraction is very different

  14. Fluorescence correction in electron probe microanalysis

    International Nuclear Information System (INIS)

    Castellano, Gustavo; Riveros, J.A.

    1987-01-01

    In this work, several expressions for characteristic fluorescence corrections are computed, for a compilation of experimental determinations on standard samples. Since this correction does not take significant values, the performance of the different models is nearly the same; this fact suggests the use of the simplest available expression. (Author) [es

  15. Open-Source Electronic Health Record Systems for Low-Resource Settings: Systematic Review.

    Science.gov (United States)

    Syzdykova, Assel; Malta, André; Zolfo, Maria; Diro, Ermias; Oliveira, José Luis

    2017-11-13

    Despite the great impact of information and communication technologies on clinical practice and on the quality of health services, this trend has been almost exclusive to developed countries, whereas countries with poor resources suffer from many economic and social issues that have hindered the real benefits of electronic health (eHealth) tools. As a component of eHealth systems, electronic health records (EHRs) play a fundamental role in patient management and effective medical care services. Thus, the adoption of EHRs in regions with a lack of infrastructure, untrained staff, and ill-equipped health care providers is an important task. However, the main barrier to adopting EHR software in low- and middle-income countries is the cost of its purchase and maintenance, which highlights the open-source approach as a good solution for these underserved areas. The aim of this study was to conduct a systematic review of open-source EHR systems based on the requirements and limitations of low-resource settings. First, we reviewed existing literature on the comparison of available open-source solutions. In close collaboration with the University of Gondar Hospital, Ethiopia, we identified common limitations in poor resource environments and also the main requirements that EHRs should support. Then, we extensively evaluated the current open-source EHR solutions, discussing their strengths and weaknesses, and their appropriateness to fulfill a predefined set of features relevant for low-resource settings. The evaluation methodology allowed assessment of several key aspects of available solutions that are as follows: (1) integrated applications, (2) configurable reports, (3) custom reports, (4) custom forms, (5) interoperability, (6) coding systems, (7) authentication methods, (8) patient portal, (9) access control model, (10) cryptographic features, (11) flexible data model, (12) offline support, (13) native client, (14) Web client,(15) other clients, (16) code

  16. Investigation of Optically Modified YBa2Cu3O7–x Films by Means of X-ray Microanalysis Technique

    Directory of Open Access Journals (Sweden)

    Artūras JUKNA

    2014-06-01

    Full Text Available This work reports on investigation of remnant oxygen content in optically-modified regions of 0.3-mm-thick YBa2Cu3O7–x films, patterned by a laser-writing technique in an inert ambient gas atmosphere at room temperature. A laser-treated region of weak superconductivity with dimensions depending on the size of a laser spot, laser power, and initial content of oxygen is characterized by a lower oxygen content, weaker critical magnetic field, and suppressed both the superconducting critical temperature and the critical current density, as compared to the laser untreated regions. Optically induced (cw-laser, 532-nm-wavelength heating strongly affects a non-uniform distribution of remnant oxygen content in the film, depending both on the optical power and beam’s scanning velocity. A level of oxygen depletion and the size of the oxygen-deficient region have been directly estimated from scanning-electron-microscope spectra with the X-ray microanalysis technique. The results of our measurements were compared with results extracted from electric measurements, assuming a correlation between the remnant oxygen content and the electric transport properties of oxygen-deficient YBa2Cu3O7–x films. DOI: http://dx.doi.org/10.5755/j01.ms.20.2.6323

  17. Characterisation of phases in nanostructured, multilayered titanium alloys by analytical and high-resolution electron microscopy.

    Science.gov (United States)

    Czyrska-Filemonowicz, A; Buffat, P A

    2009-01-01

    Surface processing of a Ti-6Al-4V alloy led to a complex multilayered microstructure containing several phases of the Ni-Ti-P-Al-O system, which improves the mechanical and tribological surface properties. The microstructure, chemical and phase compositions of the hard layer formed on the surface were investigated by LM, XRD, SEM as well as analytical/high-resolution TEM, STEM, EDS, electron diffraction and FIB. Phase identification based on electron diffraction, HRTEM and EDS microanalysis revealed the presence of several binary and ternary phases in the system Ti-Ni-P, sometimes with partial substitution of Ti by Al. However some phases, mainly nanoparticles, still remain not identified satisfactorily. Electron microscopy techniques used for identification of phases present in surface multilayers and some practical limits to their routine application are reminded here.

  18. Microanalysis on selected video clips with focus on communicative response in music therapy

    DEFF Research Database (Denmark)

    Ridder, Hanne Mette Ochsner

    2007-01-01

    This chapter describes a five-step procedure for video analysis where the topic of investigation is the communicative response of clients in music therapy. In this microanalysis procedure only very short video clips are used, and in order to select these clips an overview of each music therapy...... session is obtained with the help of a session-graph that is a systematic way of collecting video observations from one music therapy session and combining the data in one figure. The systematic procedures do not demand sophisticated computer equipment; only standard programmes such as Excel and a media...... player. They are based on individual music therapy work with a population who are difficult to engage in joint activities and who show little response (e.g. persons suffering from severe dementia). The video analysis tools might be relevant to other groups of clients where it is important to form a clear...

  19. Sample Preparation for Electron Probe Microanalysis—Pushing the Limits

    Science.gov (United States)

    Geller, Joseph D.; Engle, Paul D.

    2002-01-01

    There are two fundamental considerations in preparing samples for electron probe microanalysis (EPMA). The first one may seem obvious, but we often find it is overlooked. That is, the sample analyzed should be representative of the population from which it comes. The second is a direct result of the assumptions in the calculations used to convert x-ray intensity ratios, between the sample and standard, to concentrations. Samples originate from a wide range of sources. During their journey to being excited under the electron beam for the production of x rays there are many possibilities for sample alteration. Handling can contaminate samples by adding extraneous matter. In preparation, the various abrasives used in sizing the sample by sawing, grinding and polishing can embed themselves. The most accurate composition of a contaminated sample is, at best, not representative of the original sample; it is misleading. Our laboratory performs EPMA analysis on customer submitted samples and prepares over 250 different calibration standards including pure elements, compounds, alloys, glasses and minerals. This large variety of samples does not lend itself to mass production techniques, including automatic polishing. Our manual preparation techniques are designed individually for each sample. The use of automated preparation equipment does not lend itself to this environment, and is not included in this manuscript. The final step in quantitative electron probe microanalysis is the conversion of x-ray intensities ratios, known as the “k-ratios,” to composition (in mass fraction or atomic percent) and/or film thickness. Of the many assumptions made in the ZAF (where these letters stand for atomic number, absorption and fluorescence) corrections the localized geometry between the sample and electron beam, or takeoff angle, must be accurately known. Small angular errors can lead to significant errors in the final results. The sample preparation technique then becomes very

  20. Evaluation of three electronic report processing systems for preparing hydrologic reports of the U.S Geological Survey, Water Resources Division

    Science.gov (United States)

    Stiltner, G.J.

    1990-01-01

    In 1987, the Water Resources Division of the U.S. Geological Survey undertook three pilot projects to evaluate electronic report processing systems as a means to improve the quality and timeliness of reports pertaining to water resources investigations. The three projects selected for study included the use of the following configuration of software and hardware: Ventura Publisher software on an IBM model AT personal computer, PageMaker software on a Macintosh computer, and FrameMaker software on a Sun Microsystems workstation. The following assessment criteria were to be addressed in the pilot studies: The combined use of text, tables, and graphics; analysis of time; ease of learning; compatibility with the existing minicomputer system; and technical limitations. It was considered essential that the camera-ready copy produced be in a format suitable for publication. Visual improvement alone was not a consideration. This report consolidates and summarizes the findings of the electronic report processing pilot projects. Text and table files originating on the existing minicomputer system were successfully transformed to the electronic report processing systems in American Standard Code for Information Interchange (ASCII) format. Graphics prepared using a proprietary graphics software package were transferred to all the electronic report processing software through the use of Computer Graphic Metafiles. Graphics from other sources were entered into the systems by scanning paper images. Comparative analysis of time needed to process text and tables by the electronic report processing systems and by conventional methods indicated that, although more time is invested in creating the original page composition for an electronically processed report , substantial time is saved in producing subsequent reports because the format can be stored and re-used by electronic means as a template. Because of the more compact page layouts, costs of printing the reports were 15% to 25

  1. Electron microscopy and forensic practice

    Science.gov (United States)

    Kotrlý, Marek; Turková, Ivana

    2013-05-01

    Electron microanalysis in forensic practice ranks among basic applications used in investigation of traces (latents, stains, etc.) from crime scenes. Applying electron microscope allows for rapid screening and receiving initial information for a wide range of traces. SEM with EDS/WDS makes it possible to observe topography surface and morphology samples and examination of chemical components. Physical laboratory of the Institute of Criminalistics Prague use SEM especially for examination of inorganic samples, rarely for biology and other material. Recently, possibilities of electron microscopy have been extended considerably using dual systems with focused ion beam. These systems are applied mainly in study of inner micro and nanoparticles , thin layers (intersecting lines in graphical forensic examinations, analysis of layers of functional glass, etc.), study of alloys microdefects, creating 3D particles and aggregates models, etc. Automated mineralogical analyses are a great asset to analysis of mineral phases, particularly soils, similarly it holds for cathode luminescence, predominantly colour one and precise quantitative measurement of their spectral characteristics. Among latest innovations that are becoming to appear also at ordinary laboratories are TOF - SIMS systems and micro Raman spectroscopy with a resolution comparable to EDS/WDS analysis (capable of achieving similar level as through EDS/WDS analysis).

  2. Penelope - a code system for Monte Carlo simulation of electron and photon transport

    International Nuclear Information System (INIS)

    2003-01-01

    Radiation is used in many applications of modern technology. Its proper handling requires competent knowledge of the basic physical laws governing its interaction with matter. To ensure its safe use, appropriate tools for predicting radiation fields and doses, as well as pertinent regulations, are required. One area of radiation physics that has received much attention concerns electron-photon transport in matter. PENELOPE is a modern, general-purpose Monte Carlo tool for simulating the transport of electrons and photons, which is applicable for arbitrary materials and in a wide energy range. PENELOPE provides quantitative guidance for many practical situations and techniques, including electron and X-ray spectroscopies, electron microscopy and microanalysis, biophysics, dosimetry, medical diagnostics and radiotherapy, as well as radiation damage and shielding. These proceedings contain the extensively revised teaching notes of the second workshop/training course on PENELOPE held in 2003, along with a detailed description of the improved physic models, numerical algorithms and structure of the code system. (author)

  3. Use and User Perception of Electronic Information Resources: A Case Study of Siva Institute of Frontier Technology, India

    Directory of Open Access Journals (Sweden)

    Velmurugan Chandran

    2013-12-01

    Full Text Available The present study aims to explore the use and user perception of electronic resources in Siva Institute of Frontier Technology, India. A total number of 123 users were taken into account for the study through a questionnaire-based survey method. A well-structured questionnaire was designed and distributed to the selected 200 students and staff members. 123 copies of the questionnaires were returned dully filled in and the overall response rate was 61.50 percent. The questionnaire contained both open- and close-ended questions. The collected data were classified, analyzed, and tabulated by using simple statistical methods. This study covers the impact of electronic resources on students and faculty in their academic pursuit.

  4. A preliminary categorization of end-of-life electrical and electronic equipment as secondary metal resources

    International Nuclear Information System (INIS)

    Oguchi, Masahiro; Murakami, Shinsuke; Sakanakura, Hirofumi; Kida, Akiko; Kameya, Takashi

    2011-01-01

    Highlights: → End-of-life electrical and electronic equipment (EEE) as secondary metal resources. → The content and the total amount of metals in specific equipment are both important. → We categorized 21 EEE types from contents and total amounts of various metals. → Important equipment types as secondary resources were listed for each metal kind. → Collectability and possible collection systems of various EEE types were discussed. - Abstract: End-of-life electrical and electronic equipment (EEE) has recently received attention as a secondary source of metals. This study examined characteristics of end-of-life EEE as secondary metal resources to consider efficient collection and metal recovery systems according to the specific metals and types of EEE. We constructed an analogy between natural resource development and metal recovery from end-of-life EEE and found that metal content and total annual amount of metal contained in each type of end-of-life EEE should be considered in secondary resource development, as well as the collectability of the end-of-life products. We then categorized 21 EEE types into five groups and discussed their potential as secondary metal resources. Refrigerators, washing machines, air conditioners, and CRT TVs were evaluated as the most important sources of common metals, and personal computers, mobile phones, and video games were evaluated as the most important sources of precious metals. Several types of small digital equipment were also identified as important sources of precious metals; however, mid-size information and communication technology (ICT) equipment (e.g., printers and fax machines) and audio/video equipment were shown to be more important as a source of a variety of less common metals. The physical collectability of each type of EEE was roughly characterized by unit size and number of end-of-life products generated annually. Current collection systems in Japan were examined and potentially appropriate collection

  5. Principles of formation of the content of an educational electronic resource on the basis of general and didactic patterns of learning

    Directory of Open Access Journals (Sweden)

    Ольга Юрьевна Заславская

    2018-12-01

    Full Text Available The article considers the influence of the development of technical means of teaching on the effectiveness of educational and methodical resources. Modern opportunities of information and communication technologies allow creating electronic educational resources that represent educational information that automates the learning process, provide information assistance, if necessary, collect and process statistical information on the degree of development of the content of the school material by schoolchildren, set an individual trajectory of learning, and so on. The main principle of data organization is the division of the training course into separate sections on the thematic elements and components of the learning process. General regularities include laws that encompass the entire didactic system, and in specific (particular cases, those whose actions extend to a separate component (aspect of the system. From the standpoint of the existence of three types of electronic training modules in the aggregate content of the electronic learning resource - information, control and module of practical classes - the principles of the formation of the electronic learning resource, in our opinion, should regulate all these components. Each of the certain principles is considered in the groups: scientific orientation, methodological orientation, systemic nature, accounting of interdisciplinary connections, fundamentalization, systematic and dosage sequence, rational use of study time, accessibility, minimization, operationalization of goals, unified identification diagnosis.

  6. Decontamination in the Electron Probe Microanalysis with a Peltier-Cooled Cold Finger.

    Science.gov (United States)

    Buse, Ben; Kearns, Stuart; Clapham, Charles; Hawley, Donovan

    2016-10-01

    A prototype Peltier thermoelectric cooling unit has been constructed to cool a cold finger on an electron microprobe. The Peltier unit was tested at 15 and 96 W, achieving cold finger temperatures of -10 and -27°C, respectively. The Peltier unit did not adversely affect the analytical stability of the instrument. Heat conduction between the Peltier unit mounted outside the vacuum and the cold finger was found to be very efficient. Under Peltier cooling, the vacuum improvement associated with water vapor deposition was not achieved; this has the advantage of avoiding severe degradation of the vacuum observed when warming up a cold finger from liquid nitrogen (LN2) temperatures. Carbon contamination rates were reduced as cooling commenced; by -27°C contamination rates were found to be comparable with LN2-cooled devices. Peltier cooling, therefore, provides a viable alternative to LN2-cooled cold fingers, with few of their associated disadvantages.

  7. From Millennium ERM to Proquest 360 Resource Manager: Implementing a new Electronic Resources Management System ERMS in an International Graduate Research University in Saudi Arabia

    KAUST Repository

    Ramli, Rindra M.

    2017-05-17

    An overview of the Recommendation Study and the subsequent Implementation of a new Electronic Resources Management system ERMS in an international graduate research university in the Kingdom of Saudi Arabia. It covers the timeline, deliverables and challenges as well as lessons learnt by the Project Team.

  8. The Synthesis of the Hierarchical Structure of Information Resources for Management of Electronic Commerce Entities

    Directory of Open Access Journals (Sweden)

    Krutova Anzhelika S.

    2017-06-01

    Full Text Available The aim of the article is to develop the theoretical bases for the classification and coding of economic information and the scientific justification of the content of information resources of an electronic commerce enterprise. The essence of information resources for management of electronic business entities is investigated. It is proved that the organization of accounting in e-commerce systems is advisable to be built on the basis of two circuits: accounting for financial flows and accounting associated with transformation of business factors in products and services as a result of production activities. There presented a sequence of accounting organization that allows to combine the both circuits in a single information system, which provides a possibility for the integrated replenishment and distributed simultaneous use of the e-commerce system by all groups of users. It is proved that the guarantee of efficient activity of the information management system of electronic commerce entities is a proper systematization of the aggregate of information resources on economic facts and operations of an enterprise in accordance with the management tasks by building the hierarchy of accounting nomenclatures. It is suggested to understand nomenclature as an objective, primary information aggregate concerning a certain fact of the economic activity of an enterprise, which is characterized by minimum requisites, is entered into the database of the information system and is to be reflected in the accounting system. It is proposed to build a database of e-commerce systems as a part of directories (constants, personnel, goods / products, suppliers, buyers and the hierarchy of accounting nomenclatures. The package of documents regulating the organization of accounting at an enterprise should include: the provision on the accounting services, the order on the accounting policy, the job descriptions, the schedules of information exchange, the report card and

  9. Core Community Specifications for Electron Microprobe Operating Systems: Software, Quality Control, and Data Management Issues

    Science.gov (United States)

    Fournelle, John; Carpenter, Paul

    2006-01-01

    Modem electron microprobe systems have become increasingly sophisticated. These systems utilize either UNIX or PC computer systems for measurement, automation, and data reduction. These systems have undergone major improvements in processing, storage, display, and communications, due to increased capabilities of hardware and software. Instrument specifications are typically utilized at the time of purchase and concentrate on hardware performance. The microanalysis community includes analysts, researchers, software developers, and manufacturers, who could benefit from exchange of ideas and the ultimate development of core community specifications (CCS) for hardware and software components of microprobe instrumentation and operating systems.

  10. X-ray microanalysis of elements present in the matrix of cnidarian nematocysts.

    Science.gov (United States)

    Tardent, P; Zierold, K; Klug, M; Weber, J

    1990-01-01

    The composition and concentration of elements, in particular those of metallic cations, present in the intracapsular matrix and the wall of nematocysts of various cnidarian species have been recorded by means of X-ray microanalysis performed on 100nm thick cryosections. The predominant cation detected in the nematocyst matrix of the hydrozoan Podocoryne carnea (medusa), the scyphozoan Aurelia aurita (scyphopolyp) and the anthozoan Calliactis parasitica (tentacles and acontia) is K(+). Mg(2+) prevails in tentacular cysts of Anthopleura elegantissima, Actinia equina and Anemonia viridis, whereas, the acrorhagial cysts of A. elegantissima and A. equina contain Ca(2+) instead of Mg(2+). The acrorhagial cysts of A. viridis contain Mg(2+) like those of the tentacles. In the tentacular nematocysts of Podocoryne carnea polyps (Hydrozoa) on the other hand ambiguous element contents were found indicating that the cysts of this species has no preference for a particular cation. The high values of sulfur recorded in the matrix and particularly the wall of all the cysts are reflecting the presence of numerous protein disulfide bonds within the structural components (wall, shaft, tubule) of the nematocysts.

  11. Analytical electron microscopy of neutron-irradiated reactor alloys

    International Nuclear Information System (INIS)

    Thomas, L.E.

    1982-01-01

    Exposure to the high neutron fluxes and temperatures from 400 to 650 0 C in the core region of a fast breeder reactor profoundly alters the microstructure and properties of structural steels and superalloys. The development of irradiation-induced voids, dislocations and precipitates, as well as segregation of alloying elements on a microscopic scale has been related to macroscopic swelling, creep, hardening and embrittlement which occur during prolonged exposures in reactor. Microanalytical studies using TEM/STEM methods, primarily energy dispersive x-ray (EDX) microanalysis, have greatly aided understanding of alloy behavior under irradiation. The main uses of analytical electron microscopy in studying irradiated alloys have been the identification of irradiation-induced precipitates and determination of the changes in local composition due to irradiation-induced solute segregation

  12. Controlling user access to electronic resources without password

    Science.gov (United States)

    Smith, Fred Hewitt

    2015-06-16

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes pre-determining an association of the restricted computer resource and computer-resource-proximal environmental information. Indicia of user-proximal environmental information are received from a user requesting access to the restricted computer resource. Received indicia of user-proximal environmental information are compared to associated computer-resource-proximal environmental information. User access to the restricted computer resource is selectively granted responsive to a favorable comparison in which the user-proximal environmental information is sufficiently similar to the computer-resource proximal environmental information. In at least some embodiments, the process further includes comparing user-supplied biometric measure and comparing it with a predetermined association of at least one biometric measure of an authorized user. Access to the restricted computer resource is granted in response to a favorable comparison.

  13. Scanning and transmission electron microscopy of a craniopharyngioma: x-ray microanalytical study of the intratumoral mineralized deposits

    Energy Technology Data Exchange (ETDEWEB)

    Vilches, J.; Lopez, A.; Martinez, M.C.; Gomez, J.; Barbera, J.

    This paper discusses the value of scanning electron microscopy (SEM) and x-ray microanalysis in the classification of craniopharyngiomas. This neoplasm shows epithelial nest, cords of cuboid cells, foci of squamous metaplasia, and microcystic degeneration. SEM reveals that the epithelial cysts are lined with elongated cells that possess numerous microvilli and blebs and that some cysts are lined with polyhedral cells. The microvilli are interpreted as characteristic of the fast growing craniopharyngiomas. A microanalytical study of the calcified areas reveals the presence of magnesium, phosphorus, and calcium.

  14. Electronic theses and dissertations: a review of this valuable resource for nurse scholars worldwide.

    Science.gov (United States)

    Goodfellow, L M

    2009-06-01

    A worldwide repository of electronic theses and dissertations (ETDs) could provide worldwide access to the most up-to-date research generated by masters and doctoral students. Until that international repository is established, it is possible to access some of these valuable knowledge resources. ETDs provide a technologically advanced medium with endless multimedia capabilities that far exceed the print and bound copies of theses and dissertations housed traditionally in individual university libraries. CURRENT USE: A growing trend exists for universities worldwide to require graduate students to submit theses or dissertations as electronic documents. However, nurse scholars underutilize ETDs, as evidenced by perusing bibliographic citation lists in many of the research journals. ETDs can be searched for and retrieved through several digital resources such as the Networked Digital Library of Theses and Dissertations (http://www.ndltd.org), ProQuest Dissertations and Theses (http://www.umi.com), the Australasian Digital Theses Program (http://adt.caul.edu.au/) and through individual university web sites and online catalogues. An international repository of ETDs benefits the community of nurse scholars in many ways. The ability to access recent graduate students' research electronically from anywhere in the world is advantageous. For scholars residing in developing countries, access to these ETDs may prove to be even more valuable. In some cases, ETDs are not available for worldwide access and can only be accessed through the university library from which the student graduated. Public access to university library ETD collections is not always permitted. Nurse scholars from both developing and developed countries could benefit from ETDs.

  15. Analysis of hydrogen isotopes in materials by secondary ion mass spectrometry and nuclear microanalysis

    International Nuclear Information System (INIS)

    Ross, G.G.

    1994-01-01

    Only two techniques are really appropriate for the depth profiling of hydrogen isotopes: nuclear microanalysis (NMA) and secondary ion mass spectrometry (SIMS). The intent of this paper is to give an up to date review of both techniques and to show how they can be used in conjunction. Both techniques (SIMS and NMA) will be described briefly. NMA will divided into two different categories: nuclear reaction analysis (NRA) and elastic recoil detection (ERD). Both techniques (SIMS and NMA) will be discussed in terms of sensitivity, resolution, probing depth, quantitative measurement, generality and selectivity, beam induced effects and surface roughness effects. The principal advantages and disadvantages of each of these techniques will be specified, supporting the contention that SIMS and NMA are complementary and should be used in conjunction. Finally, some examples of, and perspectives for, the complementary use of both techniques will be presented. (Author)

  16. KAMUTHE video microanalysis system for use in Brazil: translation, cross-cultural adaptation and evidence of validity and reliability

    Directory of Open Access Journals (Sweden)

    Gustavo Schulz Gattino

    2016-11-01

    Full Text Available Background KAMUTHE is a video microanalysis system which observes preverbal communication within the music therapy setting. This system is indicated for children with autism spectrum disorder (ASD or multiple disabilities. The purpose of this study was to translate, adapt to Brazilian Portuguese language and analyze some psychometric properties (reliability and validity evidence of KAMUTHE administration in Brazil for individuals with ASD. Participants and procedure Translation, back translation, analysis by judges, and pilot application were performed to obtain evidence of content and face validity. The second part of this study was to administer KAMUTHE in 39 consecutive children with ASD. An individual session of improvisational music therapy was applied to assess the different behaviors included in KAMUTHE. The intra-rater reliability, concurrent validity and convergent validity were analyzed. Results Translation and cross-cultural adaptation were followed and some cultural adaptations were needed. Inter-rater reliability was very good (ICCs 0.95-0.99 for the three child’s behaviors analyzed. Criteria validity with a moderate negative association was found (r = –.38, p = .017 comparing the behavior “Gazes at therapist” and the level of ASD along with the Childhood Autism Rating Scale (CARS. Convergent validity was established between the behavior “Gazes at therapist” and the two nonlinguistic communication scales (social interaction and interests of the Children’s Communication Checklist (CCC with a moderate correlation (r = –.43, p = .005. Conclusions The administration of the KAMUTHE video microanalysis system showed positive results in children with ASD. Further studies are needed to improve the reliability and validity of the instrument in Brazil.

  17. Scanning electron microscopy applied to the study of solid pollution particles deposited on monumental stone; La microscopia electronica de barrido aplicada al estudio de particulas solidas de contaminacion depositadas sobre la piedra momumental

    Energy Technology Data Exchange (ETDEWEB)

    Diaz-Pache, F.; Alonso, F.J.; Esbert, R.M. [Departamento de Geologia, Universidad de Oviedo (Spain)

    1996-06-01

    Solid pollution particles play an important role in the decay of monumental stone. Scanning electron microscopy (SEM) in conjunction with microanalysis (EDX) are a very valuable study tool. In the present paper, particular attention is paid to sample collection and preparation. Examples of particles providing information on the source of decay are submitted. (Author) 9 refs.

  18. Preparation and certification of the Polish reference material Virginia Tobacco Leaves (CTA-VTL-2) for inorganic trace analysis including microanalysis

    International Nuclear Information System (INIS)

    Dybczynski, R.; Polkowska-Motrenko, H.; Samczynski, Z.; Szopa, Z.

    1997-01-01

    A new Polish certified reference material Virginia Tobacco Leaves (CTA-VTL-2) for inorganic trace analysis including microanalysis has been prepared. Certification of the candidate reference material was based on the world-wide interlaboratory comparison in which 60 laboratories from 18 countries, participated using various analytical methods and techniques. Data evaluation performed by means of the new multifunctional software package -SSQC. Recommended values were assigned for 33 and 'information' values for 10 elements, respectively. The validity of 'certified' values was confirmed for several elements using 'very accurate' methods developed in this Laboratory. (author)

  19. Library resources on the Internet

    Science.gov (United States)

    Buchanan, Nancy L.

    1995-07-01

    Library resources are prevalent on the Internet. Library catalogs, electronic books, electronic periodicals, periodical indexes, reference sources, and U.S. Government documents are available by telnet, Gopher, World Wide Web, and FTP. Comparatively few copyrighted library resources are available freely on the Internet. Internet implementations of library resources can add useful features, such as full-text searching. There are discussion lists, Gophers, and World Wide Web pages to help users keep up with new resources and changes to existing ones. The future will bring more library resources, more types of library resources, and more integrated implementations of such resources to the Internet.

  20. Genomics and X-ray microanalysis indicate that Ca2+ and thiols mediate the aggregation and adhesion of Xylella fastidiosa

    Directory of Open Access Journals (Sweden)

    Leite B.

    2002-01-01

    Full Text Available The availability of the genome sequence of the bacterial plant pathogen Xylella fastidiosa, the causal agent of citrus variegated chlorosis, is accelerating important investigations concerning its pathogenicity. Plant vessel occlusion is critical for symptom development. The objective of the present study was to search for information that would help to explain the adhesion of X. fastidiosa cells to the xylem. Scanning electron microscopy revealed that adhesion may occur without the fastidium gum, an exopolysaccharide produced by X. fastidiosa, and X-ray microanalysis demonstrated the presence of elemental sulfur both in cells grown in vitro and in cells found inside plant vessels, indicating that the sulfur signal is generated by the pathogen surface. Calcium and magnesium peaks were detected in association with sulfur in occluded vessels. We propose an explanation for the adhesion and aggregation process. Thiol groups, maintained by the enzyme peptide methionine sulfoxide reductase, could be active on the surface of the bacteria and appear to promote cell-cell aggregation by forming disulfide bonds with thiol groups on the surface of adjacent cells. The enzyme methionine sulfoxide reductase has been shown to be an auxiliary component in the adhesiveness of some human pathogens. The negative charge conferred by the ionized thiol group could of itself constitute a mechanism of adhesion by allowing the formation of divalent cation bridges between the negatively charged bacteria and predominantly negatively charged xylem walls.

  1. ELECTRONIC EDUCATIONAL RESOURCES FOR ONLINE SUPPORT OF MODERN CHEMISTRY CLASSES IN SPECIALIZED SCHOOL

    Directory of Open Access Journals (Sweden)

    Maria D. Tukalo

    2013-09-01

    Full Text Available This article contains material of some modern electronic educational resources that can be used via the Internet to support the modern chemistry classes in specialized school. It was drawn attention to the educational chemical experiments as means of knowledge; simulated key motivational characteristics to enhance students interest for learning subjects, their cognitive and practical activity in the formation of self-reliance and self-creative; commented forecasts for creating of conditions to enhance the creative potential of students in a modern learning environment.

  2. Selection and Evaluation of Electronic Resources

    Directory of Open Access Journals (Sweden)

    Doğan Atılgan

    2013-11-01

    Full Text Available Publication boom and issues related to controlling and accession of printed sources have created some problems after World War II. Consequently, publishing industry has encountered the problem of finding possible solution for emerged situation. Industry of electronic publishing has started to improve with the rapid increase of the price of printed sources as well as the problem of publication boom. The first effects of electronic publishing were appeared on the academic and scholarly publications then electronic publishing became a crucial part of all types of publications. As a result of these developments, collection developments and service policies of information centers were also significantly changed. In this article, after a general introduction about selection and evaluation processes of electronic publications, the subscribed databases by a state and a privately owned university in Turkey and their usage were examined.

  3. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    KAUST Repository

    Ramli, Rindra M.

    2017-01-01

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  4. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    KAUST Repository

    Ramli, Rindra M.

    2017-05-03

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  5. The level of the usage of the human resource information system and electronic recruitment in Croatian companies

    Directory of Open Access Journals (Sweden)

    Snježana Pivac

    2014-12-01

    Full Text Available Performing business according to contemporary requirements influences companies for continuous usage of modern managerial tools, such as a human resource information system (HRIS and electronic recruitment (ER. Human resources have been recognised as curtail resources and the main source of a competitive advantage in creation of successful business performance. In order to attract and select the top employees, companies use quality information software for attracting internal ones, and electronic recruitment for attracting the best possible external candidates. The main aim of this paper is to research the level of the usage of HRIS and ER within medium-size and large Croatian companies. Moreover, the additional aim of this paper is to evaluate the relationship among the usage of these modern managerial tools and the overall success of human resource management within these companies. For the purpose of this paper, primary and secondary research has been conducted in order to reveal the level of the usage of HRIS and ER as well as the overall success of human resource management in Croatian companies. The companies’ classification (HRIS and ER is done by using the non-hierarchical k-means cluster method as well as the nonparametric Kruskal Wallis test. Further, the companies are ranked by the multicriteria PROMETHEE method. Relevant nonparametric tests are used for testing the overall companies’ HRM. Finally, binary logistic regression is estimated, relating binary variable HRM and HRIS development. After detailed research, it can be concluded that large Croatian companies apply HRIS in majority (with a positive relation to HRM performance, but still require certain degrees of its development.

  6. Electron Energy-Loss Spectroscopy: Fundamentals and applications in the characterization of minerals

    International Nuclear Information System (INIS)

    Krishnan, K.M.

    1989-04-01

    The combined use of an energy-loss spectrometer and an analytical electron microscope with fine probe forming capabilities provides a wealth of information about the sample at high spatial resolution. Fundamental principles governing the physics of the interaction between the fast electron and a thin foil sample, to account for the fine structure in the inelastically scattered fast electron distribution (Electron-Energy Loss Spectroscopy, EELS), will be reviewed. General application of EELS is in the area of low atomic number elements (Z < 11) microanalysis, where it significantly complements the more widely used Energy Dispersive X-ray Spectroscopy (EDXS). However, a careful analysis of the low loss plasmon oscillations and the fine structure in the core-loss edges, can provide additional information related to the bonding and electronic structure of the sample. An illustration of this is presented from our study of Cδ diamond residue from the Allende carbonaceous chondrite. Combination of EELS with channeling effects can provide specific site occupation/valence information in crystalline materials. Details of this novel crystallographic method will be outlined and illustrated with an example of the study of chromite spinels. Finally, some pertinent experimental details will be discussed. 7 figs

  7. The electronic encapsulation of knowledge in hydraulics, hydrology and water resources

    Science.gov (United States)

    Abbott, Michael B.

    The rapidly developing practice of encapsulating knowledge in electronic media is shown to lead necessarily to the restructuring of the knowledge itself. The consequences of this for hydraulics, hydrology and more general water-resources management are investigated in particular relation to current process-simulation, real-time control and advice-serving systems. The generic properties of the electronic knowledge encapsulator are described, and attention is drawn to the manner in which knowledge 'goes into hiding' through encapsulation. This property is traced in the simple situations of pure mathesis and in the more complex situations of taxinomia using one example each from hydraulics and hydrology. The consequences for systems architectures are explained, pointing to the need for multi-agent architectures for ecological modelling and for more general hydroinformatics systems also. The relevance of these developments is indicated by reference to ongoing projects in which they are currently being realised. In conclusion, some more general epistemological aspects are considered within the same context. As this contribution is so much concerned with the processes of signification and communication, it has been partly shaped by the theory of semiotics, as popularised by Eco ( A Theory of Semiotics, Indiana University, Bloomington, 1977).

  8. RESEARCH OF INFLUENCE OF QUALITY OF ELECTRONIC EDUCATIONAL RESOURCES ON QUALITY OF TRAINING WITH USE OF DISTANCE TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    H. M. Kravtsov

    2013-03-01

    Full Text Available Communication improving of educational processes requires today new approaches to the management arrangements and forming of educational policy in the field of distance learning, which is based on the use of modern information and communication technologies. An important step in this process is the continuous monitoring of the development and implementation of information technology and, in particular, the distance learning systems in higher educational establishments. The main objective of the monitoring is the impact assessment on the development of distance learning following the state educational standards, curricula, methodical and technical equipment and other factors; factors revelation that influence the implementation and outcomes of distance learning; results comparison of educational institution functioning and distance education systems in order to determine the most efficient ways of its development. The paper presents the analysis results of the dependence of the quality of educational services on the electronic educational resources. Trends in educational services development was studied by comparing the quality influence of electronic educational resources on the quality of educational services of higher pedagogical educational institutions of Ukraine as of 2009-2010 and 2012-2013. Generally, the analysis of the survey results allows evaluating quality of the modern education services as satisfactory and it can be said that almost 70% of the success of their future development depends on the quality of the used electronic educational resources and distance learning systems in particular.

  9. Diagnosis of electrocution: The application of scanning electron microscope and energy-dispersive X-ray spectroscopy in five cases.

    Science.gov (United States)

    Visonà, S D; Chen, Y; Bernardi, P; Andrello, L; Osculati, A

    2018-03-01

    Deaths from electricity, generally, do not have specific findings at the autopsy. The diagnosis is commonly based on the circumstances of the death and the morphologic findings, above all the current mark. Yet, the skin injury due to an electrocution and other kinds of thermal injuries often cannot be differentiated with certainty. Therefore, there is a great interest in finding specific markers of electrocution. The search for the metallization of the skin through Scanning Electron Microscope equipped with Energy Dispersive X-Ray Spectroscopy (EDS) probe is of special importance in order to achieve a definite diagnosis in case of suspected electrocution. We selected five cases in which the electrocution was extremely likely considering the circumstances of the death. In each case a forensic autopsy was performed. Then, the skin specimens were stained with Hematoxylin Eosin and Perls. On the other hand, the skin lesions were examined with a scanning electron microscope equipped with EDS probe in order to evaluate the morphological ultrastructural features and the presence of deposits on the surface of the skin. The typical skin injury of the electrocution (current mark) were macroscopically detected in all of the cases. The microscopic examination of the skin lesions revealed the typical spherical vacuoles in the horny layer and, in the epidermis, the elongation of the cell nuclei as well as necrosis. Perls staining was negative in 4 out 6 cases. Ultrastructural morphology revealed the evident vacuolization of the horny layer, elongation of epidermic cells, coagulation of the elastic fibers. In the specimens collected from the site of contact with the conductor of case 1 and 2, the presence of the Kα peaks of iron was detected. In the corresponding specimens taken from cases 2, 4, 5 the microanalysis showed the Kα peaks of titanium. In case 3, titanium and carbon were found. In the suspicion of electrocution, the integrated use of different tools is recommended

  10. Bulk specimen X-ray microanalysis of freeze-fractured, freeze-dried tissues in gerontological research

    International Nuclear Information System (INIS)

    Nagy, I.

    1988-01-01

    The rationale for choosing the freeze-fracture freeze-drying (FFFD) method of biological bulk specimen preparation as well as the theoretical and practical problems of this method are treated. FFFD specimens are suitable for quantitative X-ray microanalysis of biologically relevant elements. Although the spatial resolution of this analytical technique is low, the application of properly selected bulk standard crystals as well as the measurement of the intracellular water and dry mass content by means of another method developed in the same laboratory, allow us to obtain useful information about the age-dependent changes of ionic composition in the main intracellular compartments. The paper summarizes the problems with regard to specimen preparation, beam penetration and the quantitative analysis of FFFD specimens. The method has been applied so far mainly for the analysis of intranuclear and intracytoplasmic concentrations of Na, C1 and K in various types of cells and has resulted in a significant contribution to our understanding of the cellular mechanisms of aging. 84 references

  11. Tracking the Flow of Resources in Electronic Waste - The Case of End-of-Life Computer Hard Disk Drives.

    Science.gov (United States)

    Habib, Komal; Parajuly, Keshav; Wenzel, Henrik

    2015-10-20

    Recovery of resources, in particular, metals, from waste flows is widely seen as a prioritized option to reduce their potential supply constraints in the future. The current waste electrical and electronic equipment (WEEE) treatment system is more focused on bulk metals, where the recycling rate of specialty metals, such as rare earths, is negligible compared to their increasing use in modern products, such as electronics. This study investigates the challenges in recovering these resources in the existing WEEE treatment system. It is illustrated by following the material flows of resources in a conventional WEEE treatment plant in Denmark. Computer hard disk drives (HDDs) containing neodymium-iron-boron (NdFeB) magnets were selected as the case product for this experiment. The resulting output fractions were tracked until their final treatment in order to estimate the recovery potential of rare earth elements (REEs) and other resources contained in HDDs. The results further show that out of the 244 kg of HDDs treated, 212 kg comprising mainly of aluminum and steel can be finally recovered from the metallurgic process. The results further demonstrate the complete loss of REEs in the existing shredding-based WEEE treatment processes. Dismantling and separate processing of NdFeB magnets from their end-use products can be a more preferred option over shredding. However, it remains a technological and logistic challenge for the existing system.

  12. Analysis of individual environmental particles using modern methods of electron microscopy and X-ray microanalysis

    International Nuclear Information System (INIS)

    Laskin, A.; Cowin, J.P.; Iedema, M.J.

    2006-01-01

    Understanding the composition of particles in the atmosphere is critical because of their health effects and their direct and indirect effects on radiative forcing, and hence on climate. In this manuscript, we demonstrate the utility of single particle off-line analysis to investigate the chemistry of individual atmospheric particles using modern, state-of-the-art electron microscopy and time-of-flight secondary ionization mass spectrometry techniques. We show that these methods provide specific, detailed data on particle composition, chemistry, morphology, phase and internal structure. This information is crucial for evaluating hygroscopic properties of aerosols, understanding aerosol aging and reactivity, and correlating the characteristics of aerosols with their optical properties. The manuscript presents a number of analytical advances in methods of electron probe particle analysis along with a brief review of a number of the research projects carried out in the authors' laboratory on the chemical characterization of environmental particles. The obtained data offers a rich set of qualitative and quantitative information on the particle chemistry, composition and the mechanisms of gas-particle interactions which are of high importance to atmospheric processes involving particulate matter and air pollution

  13. Calculated sputtering and atomic displacement cross-sections for applications to medium voltage analytical electron microscopy

    International Nuclear Information System (INIS)

    Bradley, C.R.; Zaluzec, N.J.

    1987-08-01

    The development of medium voltage electron microscopes having high brightness electron sources and ultra-high vacuum environments has been anticipated by the microscopy community now for several years. The advantages of such a configuration have been discussed to great lengths, while the potential disadvantages have for the most part been neglected. The most detrimental of these relative to microcharacterization are the effects of electron sputtering and atomic displacement to the local specimen composition. These effects have in the past been considered mainly in the high voltage electron microscope regime and generally were ignored in lower voltage instruments. Recent experimental measurements have shown that the effects of electron sputtering as well as radiation induced segregation can be observed in conventional transmission electron microscopes. It is, therefore, important to determine at what point the effects will begin to manifest themselves in the new generation of medium voltage analytical electron microscopes. In this manuscript we present new calculations which allow the individual experimentalist to determine the potential threshold levels for a particular elemental system and thus avoid the dangers of introducing artifacts during microanalysis. 12 refs., 3 figs

  14. Preparation and certification of the Polish reference material Virginia Tobacco Leaves (CTA-VTL-2) for inorganic trace analysis including microanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Dybczynski, R.; Polkowska-Motrenko, H.; Samczynski, Z.; Szopa, Z.

    1997-12-31

    A new Polish certified reference material Virginia Tobacco Leaves (CTA-VTL-2) for inorganic trace analysis including microanalysis has been prepared. Certification of the candidate reference material was based on the world-wide interlaboratory comparison in which 60 laboratories from 18 countries, participated using various analytical methods and techniques. Data evaluation performed by means of the new multifunctional software package -SSQC. Recommended values were assigned for 33 and `information` values for 10 elements, respectively. The validity of `certified` values was confirmed for several elements using `very accurate` methods developed in this Laboratory. (author). 47 refs, 28 figs, 12 tabs.

  15. Sugar microanalysis by HPLC with benzoylation: improvement via introduction of a C-8 cartridge and a high efficiency ODS column.

    Science.gov (United States)

    Miyagi, Michiko; Yokoyama, Hirokazu; Hibi, Toshifumi

    2007-07-01

    An HPLC protocol for sugar microanalysis based on the formation of ultraviolet-absorbing benzoyl chloride derivatives was improved. Here, samples were prepared with a C-8 cartridge and analyzed with a high efficiency ODS column, in which porous spherical silica particles 3 microm in diameter were packed. These devices allowed us to simultaneously quantify multiple sugars and sugar alcohols up to 10 ng/ml and to provide satisfactory separations of some sugars, such as fructose and myo-inositol and sorbitol and mannitol. This protocol, which does not require special apparatuses, should become a powerful tool in sugar research.

  16. A program for quantitative electron probe microanalysis

    International Nuclear Information System (INIS)

    Trincavelli, J.; Castellano, G.

    1987-01-01

    A complete procedure for the intensity corrections in EPMA is described, avoiding the simplifications usually found in conventional programs. In addition to the different classical expressions, this program includes the latest models for the characteristic X-ray production distribution φ(ρz). Characteristic constants for the different chemical elements are stored in data files, allowing the evaluation using subroutines of the different mass absorption coefficients for the sample. (Author) [es

  17. Optical and electron microanalysis of cuprate superconductors

    International Nuclear Information System (INIS)

    Hoff, H.A.; Osofsky, M.S.; Toth, L.E.; Richards, L.E.; Pande, C.S.; Lechter, W.L.

    1990-01-01

    Individual anisotropic grains in heterogeneous and opaque cuprate materials, when viewed in a reflected-light optical microscope through crossed polarizers, often have characteristic colors, when a daylight source is used. Of the cuprate superconductors, regardless of charge carrier type, examined so far, only one characteristic color has been observed We have studied the presence of color and found a strong correlation with the existence of superconductivity. The change in color from insulator to metal to superconductor and the compositions corresponding to these changes found by quantitative energy dispersive x-ray spectroscopy on superconducting Tl-Sr-Ca-Cu-O and metallic but not superconducting La-Sr-Cu-O materials is discussed

  18. Electron channeling X-ray microanalysis for cation configuration in irradiate magnesium alimate spinel

    International Nuclear Information System (INIS)

    Matsumura, S.; Soeda, T.; Zaluzec, N. J.; Kinoshita, C.

    1999-01-01

    High angular resolution electron channeling X-ray spectroscopy (HARECXS) was examined as a practical tool to locate lattice-ions in spinel crystals. The orientation dependent intensity distribution of emitted X-rays obtained by HARECXS is so sensitive to lattice-ion configuration in the illuminated areas that the occupation probabilities on specific positions in the crystal lattice can be determined accurately through comparison with the theoretical rocking curves. HARECXS measurements have revealed partially disordered cation arrangement in MgO·nAl 2 O 3 with n = 1.0 and 2.4. Most Al 3+ lattice-ions occupy the octahedral (VIII) sites, while Mg 2 lattice-ions reside on both the tetrahedral (IV) and the octahedral (VIII) sites. The structural vacancies are enriched in the IV-sites. Further evacuation of cations from the IV-sites to the VIII-sites is recognized in a disordering process induced by irradiation with 1 MeV Ne + ions up to 8.9 dpa at 870 K

  19. Preventing colloidal fouling in reverse osmosis and nano filtration system. Application of electron beam surface analysis; Prevencion del ensuciamiento coloidal en sistemas de osmosis inversa y nanofiltracion. Aplicacion del analisis de superficies con haces de electrones.

    Energy Technology Data Exchange (ETDEWEB)

    Sanz Ataz, J.; Guerrero Gallego, L.; Taberna Camprubi, E.; Pena Garcia, N.M; Carulla Contreras, C.; Blavia Bergos, J.

    2003-07-01

    Particulate matter in natural waters and wastewaters can cause fouling in reverse osmosis and nano filtration membranes. Common foulants includes organic and inorganic colloids; hydrous aluminum and iron silicates, silt, iron and manganese oxides, calcium carbonate, microorganisms, polysaccharides, lipoproteins, biological debris, etc. Predicting fouling of dispersed materials on membrane surface and brine flow channels uses the silt density index (SDI) and modified fouling index (MFI). Scanning electron microscopy (SEM) coupled with energy X-ray microanalysis (EDX) of SDI filters contributes to obtain information about shape, size and chemical composition of foulants and cake layer. (Author) 6 refs.

  20. Effect of different atmospheres on the electrical contact performance of electronic components under fretting wear

    Science.gov (United States)

    Liu, Xin-Long; Cai, Zhen-Bing; Cui, Ye; Liu, Shan-Bang; Xu, Xiao-Jun; Zhu, Min-Hao

    2018-04-01

    The effects of oxide etch on the surface morphology of metals for industrial application is a common cause of electrical contacts failure, and it has becomes a more severe problem with the miniaturization of modern electronic devices. This study investigated the effects of electrical contact resistance on the contactor under three different atmospheres (oxygen, air, and nitrogen) based on 99.9% copper/pogo pins contacts through fretting experiments. The results showed the minimum and stable electrical contact resistance value when shrouded in the nitrogen environment and with high friction coefficient. The rich oxygen environment promotes the formation of cuprous oxide, thereby the electrical contact resistance increases. Scanning electron microscope microscopy and electron probe microanalysis were used to analyze the morphology and distribution of elements of the wear area, respectively. The surface product between contacts was investigated by x-ray photoelectron spectroscopy analysis to explain the different electrical contact properties of the three tested samples during fretting.

  1. Sodium lauryl sulfate enhances nickel penetration through guinea-pig skin. Studies with energy dispersive X-ray microanalysis

    International Nuclear Information System (INIS)

    Lindberg, M.; Sagstroem, S.R.; Roomans, G.M.; Forslind, B.

    1989-01-01

    The effect of sodium lauryl sulphate (SLS), a common ingredient of detergents, on the penetration of nickel through the stratum corneum in the guinea-pig skin model was studied with energy dispersive X-ray microanalysis (EDX) to evaluate the barrier-damaging properties of this common detergent. The EDX technique allows a simultaneous determination of physiologically important elements, e.g., Na, Mg, P, Cl, K, Ca and S in addition to Ni at each point of measurement in epidermal cell strata. Our results show that SLS reduces the barrier function to Ni-ion penetration of the stratum corneum. In addition we have shown that EDX allows analysis of the influence of different factors involved in nickel penetration through the skin by giving data on the physiological effects on the epidermal cells caused by the applied substances

  2. Magmatic Vapor Phase Transport of Copper in Reduced Porphyry Copper-Gold Deposits: Evidence From PIXE Microanalysis of Fluid Inclusions

    Science.gov (United States)

    Rowins, S. M.; Yeats, C. J.; Ryan, C. G.

    2002-05-01

    Nondestructive proton-induced X-ray emission (PIXE) studies of magmatic fluid inclusions in granite-related Sn-W deposits [1] reveal that copper transport out of reduced felsic magmas is favored by low-salinity vapor and not co-existing high-salinity liquid (halite-saturated brine). Copper transport by magmatic vapor also has been documented in oxidized porphyry Cu-Au deposits, but the magnitude of Cu partitioning into the vapor compared to the brine generally is less pronounced than in the reduced magmatic Sn-W systems [2]. Consideration of these microanalytical data leads to the hypothesis that Cu and, by inference, Au in the recently established "reduced porphyry copper-gold" (RPCG) subclass should partition preferentially into vapor and not high-salinity liquid exsolving directly from fluid-saturated magmas [3-4]. To test this hypothesis, PIXE microanalysis of primary fluid inclusions in quartz-sulfide (pyrite, pyrrhotite & chalcopyrite) veins from two RPCG deposits was undertaken using the CSIRO-GEMOC nuclear microprobe. PIXE microanalysis for the ~30 Ma San Anton deposit (Mexico) was done on halite-saturated aqueous brine (deposit (W. Australia) was done on halite-saturated "aqueous" inclusions, which contain a small (deposits of the new RPCG subclass demonstrate the greater potential of these systems, compared to the classically oxidized porphyry Cu-Au systems, to transport Cu and probably precious metals in a magmatic aqueous vapor phase. These PIXE data also support the possibility that Cu partitions preferentially into an immiscible CO2-rich magmatic fluid. References: [1] Heinrich, C.A. et al. (1992) Econ. Geol., 87, 1566-1583. [2] Heinrich, C.A. et al. (1999) Geology, 27, 755-758. [3] Rowins, S.M. (2000) Geology, 28, 491-494. [4] Rowins, S.M. (2000) The Gangue, GAC-MDD Newsletter, 67, 1-7 (www.gac.ca). [5] Rowins, S.M. et al. (1993) Geol. Soc. Australia Abs., 34, 68-70.

  3. Atomic imaging and microanalysis of ceramics

    International Nuclear Information System (INIS)

    Thomas, G.; Ramesh, R.

    1988-10-01

    This paper is a short review of electron microscopy techniques, as applied to modern ceramics. Examples: representative of the significance of modern electron microscopy, methods of atomic resolution imaging, diffraction and spectroscopy in the task of characterising, and understanding typical ceramic materials are given. (JL)

  4. Using mobile electronic devices to deliver educational resources in developing countries.

    Science.gov (United States)

    Mazal, Jonathan Robert; Ludwig, Rebecca

    2015-01-01

    Developing countries have far fewer trained radiography professionals than developed countries, which exacerbates the limited access to imaging services. The lack of trained radiographers reflects, in part, limited availability of radiographer-specific educational resources. Historically, organizations that provided such resources in the developing world faced challenges related to the limited stock of current materials as well as expenses associated with shipping and delivery. Four mobile electronic devices (MEDs) were loaded with educational content (e-books, PDFs, and digital applications) spanning major radiography topics. The MEDs were distributed to 4 imaging departments in Ghana, India, Nepal, and Nigeria based on evidence of need for radiography-specific resources, as revealed by survey responses. A cost comparison of postal delivery vs digital delivery of educational content was performed. The effectiveness of delivering additional content via Wi-Fi transmission also was evaluated. Feedback was solicited on users' experience with the MEDs as a delivery tool for educational content. An initial average per e-book expense of $30.05, which included the cost of the device, was calculated for the MED delivery method compared with $15.56 for postal delivery of printed materials. The cost of the MED delivery method was reduced to an average of $10.05 for subsequent e-book deliveries. Additional content was successfully delivered via Wi-Fi transmission to all recipients during the 3-month follow-up period. Overall user feedback on the experience was positive, and ideas for enhancing the MED-based method were identified. Using MEDs to deliver radiography-specific educational content appears to be more cost effective than postal delivery of printed materials on a long-term basis. MEDs are more efficient for providing updates to educational materials. Customization of content to department needs, and using projector devices could enhance the usefulness of MEDs for

  5. Success criteria for electronic medical record implementations in low-resource settings: a systematic review.

    Science.gov (United States)

    Fritz, Fleur; Tilahun, Binyam; Dugas, Martin

    2015-03-01

    Electronic medical record (EMR) systems have the potential of supporting clinical work by providing the right information at the right time to the right people and thus make efficient use of resources. This is especially important in low-resource settings where reliable data are also needed to support public health and local supporting organizations. In this systematic literature review, our objectives are to identify and collect literature about success criteria of EMR implementations in low-resource settings and to summarize them into recommendations. Our search strategy relied on PubMed queries and manual bibliography reviews. Studies were included if EMR implementations in low-resource settings were described. The extracted success criteria and measurements were summarized into 7 categories: ethical, financial, functionality, organizational, political, technical, and training. We collected 381 success criteria with 229 measurements from 47 articles out of 223 articles. Most papers were evaluations or lessons learned from African countries, published from 1999 to 2013. Almost half of the EMR systems served a specific disease area like human immunodeficiency virus (HIV). The majority of criteria that were reported dealt with the functionality, followed by organizational issues, and technical infrastructures. Sufficient training and skilled personnel were mentioned in roughly 10%. Political, ethical, and financial considerations did not play a predominant role. More evaluations based on reliable frameworks are needed. Highly reliable data handling methods, human resources and effective project management, as well as technical architecture and infrastructure are all key factors for successful EMR implementation. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Chemometric classification of gunshot residues based on energy dispersive X-ray microanalysis and inductively coupled plasma analysis with mass-spectrometric detection

    International Nuclear Information System (INIS)

    Steffen, S.; Otto, M.; Niewoehner, L.; Barth, M.; Brozek-Mucha, Z.; Biegstraaten, J.; Horvath, R.

    2007-01-01

    A gunshot residue sample that was collected from an object or a suspected person is automatically searched for gunshot residue relevant particles. Particle data (such as size, morphology, position on the sample for manual relocation, etc.) as well as the corresponding X-ray spectra and images are stored. According to these data, particles are classified by the analysis-software into different groups: 'gunshot residue characteristic', 'consistent with gunshot residue' and environmental particles, respectively. Potential gunshot residue particles are manually checked and - if necessary - confirmed by the operating forensic scientist. As there are continuing developments on the ammunition market worldwide, it becomes more and more difficult to assign a detected particle to a particular ammunition brand. As well, the differentiation towards environmental particles similar to gunshot residue is getting more complex. To keep external conditions unchanged, gunshot residue particles were collected using a specially designed shooting device for the test shots revealing defined shooting distances between the weapon's muzzle and the target. The data obtained as X-ray spectra of a number of particles (3000 per ammunition brand) were reduced by Fast Fourier Transformation and subjected to a chemometric evaluation by means of regularized discriminant analysis. In addition to the scanning electron microscopy in combination with energy dispersive X-ray microanalysis results, isotope ratio measurements based on inductively coupled plasma analysis with mass-spectrometric detection were carried out to provide a supplementary feature for an even lower risk of misclassification

  7. Chemometric classification of gunshot residues based on energy dispersive X-ray microanalysis and inductively coupled plasma analysis with mass-spectrometric detection

    Energy Technology Data Exchange (ETDEWEB)

    Steffen, S. [Bundeskriminalamt (BKA), Forensic Science Institute KT23, Thaerstr. 11, D - 65193 Wiesbaden (Germany); Otto, M. [TU Bergakademie Freiberg (TU BAF), Institute for Analytical Chemistry, Leipziger Str. 29, D - 09599 Freiberg (Germany)], E-mail: matthias.otto@chemie.tu-freiberg.de; Niewoehner, L.; Barth, M. [Bundeskriminalamt (BKA), Forensic Science Institute KT23, Thaerstr. 11, D - 65193 Wiesbaden (Germany); Brozek-Mucha, Z. [Instytut Ekspertyz Sadowych (IES), Westerplatte St. 9, PL - 31-033 Krakow (Poland); Biegstraaten, J. [Nederlands Forensisch Instituut (NFI), Fysische Technologie, Laan van Ypenburg 6, NL-2497 GB Den Haag (Netherlands); Horvath, R. [Kriminalisticky a Expertizny Ustav (KEU PZ), Institute of Forensic Science, Sklabinska 1, SK - 812 72 Bratislava (Slovakia)

    2007-09-15

    A gunshot residue sample that was collected from an object or a suspected person is automatically searched for gunshot residue relevant particles. Particle data (such as size, morphology, position on the sample for manual relocation, etc.) as well as the corresponding X-ray spectra and images are stored. According to these data, particles are classified by the analysis-software into different groups: 'gunshot residue characteristic', 'consistent with gunshot residue' and environmental particles, respectively. Potential gunshot residue particles are manually checked and - if necessary - confirmed by the operating forensic scientist. As there are continuing developments on the ammunition market worldwide, it becomes more and more difficult to assign a detected particle to a particular ammunition brand. As well, the differentiation towards environmental particles similar to gunshot residue is getting more complex. To keep external conditions unchanged, gunshot residue particles were collected using a specially designed shooting device for the test shots revealing defined shooting distances between the weapon's muzzle and the target. The data obtained as X-ray spectra of a number of particles (3000 per ammunition brand) were reduced by Fast Fourier Transformation and subjected to a chemometric evaluation by means of regularized discriminant analysis. In addition to the scanning electron microscopy in combination with energy dispersive X-ray microanalysis results, isotope ratio measurements based on inductively coupled plasma analysis with mass-spectrometric detection were carried out to provide a supplementary feature for an even lower risk of misclassification.

  8. Electronic Human Resources Management (e-HRM Adoption Studies: Past and Future Research

    Directory of Open Access Journals (Sweden)

    Winarto Winarto

    2018-05-01

    Full Text Available Electronic human resource management (e-HRM systems become more widely used by profit and non-profit organization. However, the field currently lacks sound theoretical frameworks that can be useful in addressing a key issue concerning the implementation of e-HRM systems, in particular to obtain a better understanding of the factors influencing the adoption of e-HRM systems. The objective of this paper is to provide a foundation towards the development of a theoretical framework for the implementation of e-HRM systems and develop a conceptual model that would reflect the nature of e-HRM systems’ adoption through systematic literature review. Adopting Crossan and Apaydin’s procedure of systematic review, this paper investigated 21 empirical papers of electronics human resources management, then categorized them into 4 characteristics which influence the adoption; System and technology characteristics; Organizational characteristics; User/individual characteristics, and Environmental and contextual characteristics. Finally, the e-HRM adoption research framework is drawn and based on the framework; avenues for future research are discussed.   Bahasa Indonesia Abstrak: Manajemen sumber daya manusia elektronik (selanjutnya disebut dengan e-HRM semakin banyak digunakan oleh organisasi profit dan nonprofit. Namun, bidang dan topik ini belum memiliki kerangka teori yang mapan, yang dapat digunakan untuk menganalisis isu-isu terkait penerapan e-HRM, terutama mengenai faktor-faktor yang mempengaruhi adopsi sistem e-HRM. Tujuan penelitian ini adalah untuk memberikan landasan bagi pengembangan kerangka teoritis untuk implementasi sistem e-HRM dan mengembangkan model konseptual yang akan menggambarkan adopsi sistem e-HRM melalui tinjauan literatur sistematis. Mengadopsi prosedur dan metode Crossan dan Apaydin untuk melakukan telaah literatur secara sistematis, paper ini menyelidiki 21 publikasi empiris manajemen sumber daya manusia elektronik dari 2

  9. Enumeration and biomass estimation of planktonic bacteria and viruses by transmission electron microscopy

    International Nuclear Information System (INIS)

    Borsheim, K.Y.; Bratbak, G.; Heldal, M.

    1990-01-01

    Bacteria and virus particles were harvested from water samples by ultracentrifugation directly onto Formvar-coated electron microscopy grids and counted in a transmission electron microscope. With this technique, we have counted and sized bacteria and viruses in marine water samples and during laboratory incubations. By X-ray microanalysis, we could determine the elemental composition and dry-matter content of individual bacteria. The dry weight/volume ratio for the bacteria was 600 fg of dry weight microns-3. The potassium content of the bacteria was normal compared with previous estimates from other bacterial assemblages; thus, this harvesting procedure did not disrupt the bacterial cells. Virus particles were, by an order of magnitude, more abundant than bacteria in marine coastal waters. During the first 5 to 7 days of incubation, the total number of viruses increased exponentially at a rate of 0.4 day-1 and thereafter declined. The high proliferation rate suggests that viral parasitism may affect mortality of bacteria in aquatic environments

  10. Electron backscatter diffraction applied to lithium sheets prepared by broad ion beam milling.

    Science.gov (United States)

    Brodusch, Nicolas; Zaghib, Karim; Gauvin, Raynald

    2015-01-01

    Due to its very low hardness and atomic number, pure lithium cannot be prepared by conventional methods prior to scanning electron microscopy analysis. Here, we report on the characterization of pure lithium metallic sheets used as base electrodes in the lithium-ion battery technology using electron backscatter diffraction (EBSD) and X-ray microanalysis using energy dispersive spectroscopy (EDS) after the sheet surface was polished by broad argon ion milling (IM). No grinding and polishing were necessary to achieve the sufficiently damage free necessary for surface analysis. Based on EDS results the impurities could be characterized and EBSD revealed the microsctructure and microtexture of this material with accuracy. The beam damage and oxidation/hydration resulting from the intensive use of IM and the transfer of the sample into the microscope chamber was estimated to be effect on the surface temperature. However, a cryo-stage should be used if available during milling to guaranty a heating artefact free surface after the milling process. © 2014 Wiley Periodicals, Inc.

  11. Healthy and diseased striated muscle studied by analytical scanning electron microscopy with special reference to fibre type

    International Nuclear Information System (INIS)

    Wroblewski, R.

    1982-01-01

    X-ray microanalytical investigations of striated muscles in the scanning electron microscope are reviewed. The main part of the studies was performed on cryosections cut with a conventional cryostat operating at -20 degrees C to -40 degrees C. The preparation procedure including different types of attachment of the sections to the specimen holder is described in detail. The elemental changes in muscle are related to the muscle fibre type as demonstrated by histochemical methods or to histochemically demonstrated inclusions in diseased muscles. This is of great importance, because muscle disorders are often characterised by selective involvement of different muscle fibre types. The preparation methods of muscle for analytical scanning electron microscopy and the obtained results are compared with studies performed on thin cryo and epoxy sections, analysed in the transmission and scanning-transmission electron microscope. It is evident that X-ray microanalysis performed on thick cryosections provide a quick survey of the elemental composition of whole cells, and should be followed in interesting cases by close examination on the organelle level studied in thin cryosections in the transmission and scanning-transmission electron microscope

  12. Improving Electronic Resources through Holistic Budgeting

    Science.gov (United States)

    Kusik, James P.; Vargas, Mark A.

    2009-01-01

    To establish a more direct link between its collections and the educational goals of Saint Xavier University, the Byrne Memorial Library has adopted a "holistic" approach to collection development. This article examines how traditional budget practices influenced the library's selection of resources and describes how holistic collection…

  13. Th-U-PbT dating by Electron Probe Microanalysis, Part I. Monazite: analytical procedures and data treatment

    International Nuclear Information System (INIS)

    Vlach, Silvio Roberto Farias

    2010-01-01

    Dating methodology by the electron probe microanalyser (EPMA) of (Th, U)-bearing minerals, highlighting monazite, acquired greater than ever importance in literature, particularly due to its superior spatial resolution, as well as versatility, which allow correlating petrological processes at times registered only in micro-scales in minerals and rocks with absolute ages. Although the accuracy is inferior to the one achieved with conventional isotopic methods in up to an order of magnitude, EPMA is the instrument that allows the best spatial resolution, reaching a few μm 3 in some conditions. Quantification of minor and trace elements with suitable precision and accuracy involves the own instrumental and analytical set-ups and data treatment strategies, significantly more rigorous when compared with those applied in conventional analyses. Th-U-Pb T dating is an example of these cases. Each EPMA is a unique machine as for its instrumental characteristics and respective automation system. In such a way, analytical procedures ought to be adjusted for laboratory specificities. The analytical strategies and data treatment adopted in the Electronic Microprobe Laboratory from Instituto de Geociencias of Universidade de Sao Paulo, Brazil, with a JEOL JXA8600S EPMA, and a ThermoNoran-Voyager 4.3 automation system, are presented and compared with the ones used in other laboratories. The influence of instrumental factors and spectral overlaps on Th, U, and Pb quantification is discussed. Applied procedures to interference correction, error propagation, data treatment, and fi nal chemical age presentation as well as to sampling and analyses are emphasized. Some typical applications are discussed, drawing attention to the most relevant aspects of electron microprobe dating. (author)

  14. Clinician‐selected Electronic Information Resources do not Guarantee Accuracy in Answering Primary Care Physicians’ Information Needs. A review of: McKibbon, K. Ann, and Douglas B. Fridsma. “Effectiveness of Clinician‐selected Electronic Information Resources for Answering Primary Care Physicians’ Information Needs.” Journal of the American Medical Informatics Association 13.6 (2006: 653‐9.

    Directory of Open Access Journals (Sweden)

    Martha Ingrid Preddie

    2008-03-01

    Full Text Available Objective – To determine if electronic information resources selected by primary care physicians improve their ability to answer simulated clinical questions.Design – An observational study utilizing hour‐long interviews and think‐aloud protocols.Setting – The offices and clinics of primary care physicians in Canada and the United States.Subjects – Twenty‐five primary care physicians of whom 4 were women, 17 were from Canada, 22 were family physicians,and 24 were board certified.Methods – Participants provided responses to 23 multiple‐choice questions. Each physician then chose two questions and looked for the answers utilizing information resources of their own choice. The search processes, chosen resources and search times were noted. These were analyzed along with data on the accuracy of the answers and certainties related to the answer to each clinical question prior to the search.Main results – Twenty‐three physicians sought answers to 46 simulated clinical questions. Utilizing only electronic information resources, physicians spent a mean of 13.0 (SD 5.5 minutes searching for answers to the questions, an average of 7.3(SD 4.0 minutes for the first question and 5.8 (SD 2.2 minutes to answer the second question. On average, 1.8 resources were utilized per question. Resources that summarized information, such as the Cochrane Database of Systematic Reviews, UpToDate and Clinical Evidence, were favored 39.2% of the time, MEDLINE (Ovid and PubMed 35.7%, and Internet resources including Google 22.6%. Almost 50% of the search and retrieval strategies were keyword‐based, while MeSH, subheadings and limiting were used less frequently. On average, before searching physicians answered 10 of 23 (43.5% questions accurately. For questions that were searched using clinician‐selected electronic resources, 18 (39.1% of the 46 answers were accurate before searching, while 19 (42.1% were accurate after searching. The difference of

  15. Spatially resolved quantification of agrochemicals on plant surfaces using energy dispersive X-ray microanalysis.

    Science.gov (United States)

    Hunsche, Mauricio; Noga, Georg

    2009-12-01

    In the present study the principle of energy dispersive X-ray microanalysis (EDX), i.e. the detection of elements based on their characteristic X-rays, was used to localise and quantify organic and inorganic pesticides on enzymatically isolated fruit cuticles. Pesticides could be discriminated from the plant surface because of their distinctive elemental composition. Findings confirm the close relation between net intensity (NI) and area covered by the active ingredient (AI area). Using wide and narrow concentration ranges of glyphosate and glufosinate, respectively, results showed that quantification of AI requires the selection of appropriate regression equations while considering NI, peak-to-background (P/B) ratio, and AI area. The use of selected internal standards (ISs) such as Ca(NO(3))(2) improved the accuracy of the quantification slightly but led to the formation of particular, non-typical microstructured deposits. The suitability of SEM-EDX as a general technique to quantify pesticides was evaluated additionally on 14 agrochemicals applied at diluted or regular concentration. Among the pesticides tested, spatial localisation and quantification of AI amount could be done for inorganic copper and sulfur as well for the organic agrochemicals glyphosate, glufosinate, bromoxynil and mancozeb. (c) 2009 Society of Chemical Industry.

  16. A review on the use of bulk specimen X-ray microanalysis in cancer research

    International Nuclear Information System (INIS)

    Zs-Nagy, I.

    1989-01-01

    The freeze-fracture, freeze-drying (FFFD) method of biological bulk specimen preparation combined with quantitative X-ray microanalysis is suitable for the measurement of intracellular concentrations of biologically relevant elements in human biopsy or experimental animal materials. Especially useful information can be obtained regarding the intracellular Na+/K+ ratios being independent of the actual (and unknown) water content of the cytoplasm. The sustained increase of this ratio indicates a sustained depolarization of the cell membrane. These data are of importance from the point of view of the membrane hypothesis of mitogenesis (MHM). It has been revealed that the distribution histograms of the intracellular Na+/K+ ratio display a very significant broadening and an increase of the average values in human urogenital, thyroid and laryngeal tumors, as well as in experimentally induced cell proliferation models. Although MHM has been claimed to be invalid on the basis of some atomic absorption measurements of the intracellular monovalent ion concentrations as well as of some in vitro results obtained with amiloride, this review paper demonstrates that MHM may still be a valid hypothesis for the explanation of mitotic regulation.97 references

  17. Review of material recovery from used electric and electronic equipment-alternative options for resource conservation.

    Science.gov (United States)

    Friege, Henning

    2012-09-01

    For waste from electric and electronic equipment, the WEEE Directive stipulates the separate collection of electric and electronic waste. As to new electric and electronic devices, the Restriction of Hazardous Substances (RoHS) Directive bans the use of certain chemicals dangerous for man and environment. From the implementation of the WEEE directive, many unsolved problems have been documented: poor collection success, emission of dangerous substances during collection and recycling, irretrievable loss of valuable metals among others. As to RoHS, data from the literature show a satisfying success. The problems identified in the process can be reduced to some basic dilemmas at the borders between waste management, product policy and chemical safety. The objectives of the WEEE Directive and the specific targets for use and recycling of appliances are not consistent. There is no focus on scarce resources. Extended producer responsibility is not sufficient to guarantee sustainable waste management. Waste management reaches its limits due to problems of implementation but also due to physical laws. A holistic approach is necessary looking at all branch points and sinks in the stream of used products and waste from electric and electronic equipment. This may be done with respect to the general rules for sustainable management of material streams covering the three dimensions of sustainable policy. The relationships between the players in the field of electric and electronic devices have to be taken into account. Most of the problems identified in the implementation process will not be solved by the current amendment of the WEEE Directive.

  18. Charting a Course through CORAL: Texas A&M University Libraries' Experience Implementing an Open-Source Electronic Resources Management System

    Science.gov (United States)

    Hartnett, Eric; Beh, Eugenia; Resnick, Taryn; Ugaz, Ana; Tabacaru, Simona

    2013-01-01

    In 2010, after two previous unsuccessful attempts at electronic resources management system (ERMS) implementation, Texas A&M University (TAMU) Libraries set out once again to find an ERMS that would fit its needs. After surveying the field, TAMU Libraries selected the University of Notre Dame Hesburgh Libraries-developed, open-source ERMS,…

  19. Effect of impurity inhomogeneity of CdS and CdSe monocrystalline semiconductors on electron absorption of piezoactive ultrasonic waves

    International Nuclear Information System (INIS)

    Ketis, B.P.; Krivka, I.

    1986-01-01

    Relation of observed anomalies (deviations from predictions of theory for homogeneous piezosemiconductor) of electronic absorption coefficient (EAC) of volume, piezoactive acoustic waves (with 15 MHz frequency) in CdS and CdSe hexagonal crystals with electrical heterogeneity is shown experimentally. Results of electron microanalysis of CdS and CdSe piezosemiconductors confirmed their impurity heterogeneity are presented as well as data of investigations into high-frequency conduction and electronic absorption of ultrasonic waves pointing out to volume nature of impurity and electric heterogeneities of monocrystals investigated. Correlation between EAC anomalies and surface density of impurity aggregates (IA) is noted as well as coincidence of impurity and electrical heterogeneities in CdS and CdSe crystals. In CdS crystals the observed anisotropy of high-frequency conduction and volume radioactive ultrasonic waves EAC is attributed to high density and anisotropy of IA space distribution and shape. To explain EAC anomalies, a crystal is simulated with heterogeneous grid of resistances and condensators

  20. Designing a model of electronic human resource management’s implementation at the Ministry of Communications and Information Technology

    Directory of Open Access Journals (Sweden)

    Mirali Seyednaghavi

    2017-06-01

    Full Text Available : In the first phase of this study a model for electronic human resource management in government agencies based on new public services was explored by using software MAXQDA, then in the second phase, relationship between the elements of the theory were tested using software Smart PLS2. So the aim of this study is to design a model of electronic human resource management’s implementation at the Ministry of Communications and Information Technology. In this regard, according to Strauss and Corbin’s structured plan, five hypotheses were tested. Quantitative data analysis indicates that the pressures of the policies and global perspectives cause to move toward e-HRM. Among the contextual conditions macro structural mechanisms, considerations of actors, governance considerations have a significant impact on the strategy of new public services and therefore lead to the consequences of its implementation in public organizations. The findings suggest that e-HRM does not have a positive and meaningful impact on new public services, and in our country, although the recent political developments have somehow removed the gap between public policy makers, administrators, and the public, but there is still a long way to go.

  1. The Changes of Elements Composition in Aspergillus niger and Aspergillus terreus at Different Co2+, Cd2+ and Pb2+ Concentrations Using X-rays Microanalysis

    International Nuclear Information System (INIS)

    Ouda, S.M.

    2010-01-01

    X-ray microanalysis in electron microscope allows simultaneous detection and quantitative analysis of several elements so it contributes to understand the role of ions in physiological processes. Energy dispersive X-ray (EDX) analysis used to detect the changes in elements levels in Aspergillus niger and Aspergillus terreus when allowing to grow on Czapek's Dox liquid media amended with different Co 2+ , Cd 2+ and Pb 2+ concentrations and these changes may play a role in fungal uptake for these heavy metal ions. Results showed that Ca, Zn and Cu levels in both fungal isolates significantly decreased (P<0.05) when concentrations of used metal ions increased, also O, Na, Cl and K levels for A. niger and C and P for A. terreus recorded significant reduction (P<0.05) in their percentages. Also, the results revealed that, C and P for A. niger and O, Na, Mg, Cl and K levels for A. terreus significantly increased (P<0.05) as a result of increasing metal ions concentrations. Lack of Cd and Pb peaks in X-ray spectrum for A. terreus led this work to conclude that, A. niger was more effective than A. terreus in Co, Cd, Pb uptake into fungal biomass. The increase or decrease of levels of detected elements could be related to the difference between two fungal isolates in uptake certain heavy metal ion (Co, Cd, Pb)

  2. Measurements of absolute M-subshell X-ray production cross sections of Th by electron impact

    Energy Technology Data Exchange (ETDEWEB)

    Moy, A., E-mail: aurelien.moy@cea.fr [GM, CNRS, Université de Montpellier II, Place E. Bataillon, F-34095 Montpellier (France); CEA, DEN, DTEC, SGCS, LMAC, F-30207 Bagnols-sur-Cèze (France); Merlet, C. [GM, CNRS, Université de Montpellier II, Place E. Bataillon, F-34095 Montpellier (France); Dugne, O. [CEA, DEN, DTEC, SGCS, LMAC, F-30207 Bagnols-sur-Cèze (France)

    2014-08-31

    Highlights: • The M X-ray production cross sections of Th were measured by electron impact. • The M-subshell ionization cross sections of Th were determined from 3 to 38 keV. • Theoretical ionization cross-sections are in agreement with our experimental results. - Abstract: Measurements of absolute M-subshell X-ray production cross sections for element Th were made by electron impact for energies ranging from the ionization threshold up to 38 keV. Experimental data were obtained by measuring the X-ray intensity emitted from ultrathin Th films deposited onto self-supporting C backing films. The measurements were conducted with an electron microprobe using high-resolution wavelength dispersive spectrometers. Recorded intensities were converted into absolute X-ray production cross sections by means of atomic data and estimation of the number of primary electrons, target thickness, and detector efficiency. Our experimental X-ray production cross sections, the first to be reported for the M subshells of Th, are compared with X-ray production cross sections calculated with the mean of ionization cross sections obtained from the distorted-wave Born approximation. The Mα X-ray production cross section calculated is in excellent agreement with the measurements, allowing future use for standardless quantification in electron probe microanalysis.

  3. Quantitative electron probe microanalysis of borides in aluminium

    International Nuclear Information System (INIS)

    Karduck, P.; Schuerhoff, H.J.; Burchard, W.G.

    1983-01-01

    A procedure for the quantitative analysis of borides in aluminium was introduced. For this purpose the optimal apparative boundary conditions for the EPMA of boron were worked out. With these conditions a satisfactory peak to background ratio of 57 could be achieved for B-Kα-radiation. By application of this method the following conclusion should be drawn concerning the kind of nuclei during grain refinement of aluminium with titanium and boron: For grain refinement of aluminium with titanium and boron in the hypoperitectic region of the binary system Al-Ti TiB 2 -particles in clusters provide the high efficiency of refinement. This entails that the TiB 2 -particles already present in the master alloy remain inert in the melt. Hence, the good efficiency of refinement in this region cannot be attributed to the presence of particles like Al 3 Ti, AlB 2 or (Al, Ti) B 2 . (Author)

  4. The module of methodical support in system of electronic educational resources as the innovative element of the modern maintenance of formation

    Directory of Open Access Journals (Sweden)

    Ольга Николаевна Крылова

    2009-06-01

    Full Text Available The article introduces some results of research, which were devoted to evaluation of tearches' mobility to introduce innovations in the contents of education. The author considers innovative potential of modules of the methodical support for system of electronic educational resources.

  5. Clinical applications of scanning electron microscopy and energy dispersive X-ray analysis in dermatology--an up-date

    International Nuclear Information System (INIS)

    Forslind, B.

    1988-01-01

    Dermatological papers comprising scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) analysis data published 1983 through 1986 in international journals are reviewed, as an update to our 1984 paper on Clinical applications of scanning electron microscopy and X-ray microanalysis in dermatology. The present paper not only deals with a review of recent publications in this area but also presents the application of microincineration to hair and cryosectioned freeze-dried skin specimens. Examples of the increased contrast obtained in hair cross sections are presented and a discussion on the feasibility of microincineration at analysis of hair and skin cross sections is given. Particle probe analysis (EDX: energy dispersive X-ray analysis and PMP: proton microprobe analysis) as applied to hair and skin samples are presented with stress put on the proton probe analysis. The complementarity of EDX and PMP is demonstrated and future applications are suggested. 75 references

  6. Sub-microanalysis of solid samples with near-field enhanced atomic emission spectroscopy

    Science.gov (United States)

    Wang, Xiaohua; Liang, Zhisen; Meng, Yifan; Wang, Tongtong; Hang, Wei; Huang, Benli

    2018-03-01

    A novel approach, which we have chosen to name it as near-field enhanced atomic emission spectroscopy (NFE-AES), was proposed by introducing a scanning tunnelling microscope (STM) system into a laser-induced breakdown spectrometry (LIBS). The near-field enhancement of a laser-illuminated tip was utilized to improve the lateral resolution tremendously. Using the hybrid arrangement, pure metal tablets were analyzed to verify the performance of NFE-AES both in atmosphere and in vacuum. Due to localized surface plasmon resonance (LSPR), the incident electromagnetic field is enhanced and confined at the apex of tip, resulting in sub-micron scale ablation and elemental emission signal. We discovered that the signal-to-noise ratio (SNR) and the spectral resolution obtained in vacuum condition are better than those acquired in atmospheric condition. The quantitative capability of NFE-AES was demonstrated by analyzing Al and Pb in Cu matrix, respectively. Submicron-sized ablation craters were achieved by performing NFE-AES on a Si wafer with an Al film, and the spectroscopic information from a crater of 650 nm diameter was successfully obtained. Due to its advantage of high lateral resolution, NFE-AES imaging of micro-patterned Al lines on an integrated circuit of a SIM card was demonstrated with a sub-micron lateral resolution. These results reveal the potential of the NFE-AES technique in sub-microanalysis of solids, opening an opportunity to map chemical composition at sub-micron scale.

  7. Impact of Electronic Resources and Usage in Academic Libraries in Ghana: Evidence from Koforidua Polytechnic & All Nations University College, Ghana

    Science.gov (United States)

    Akussah, Maxwell; Asante, Edward; Adu-Sarkodee, Rosemary

    2015-01-01

    The study investigates the relationship between impact of electronic resources and its usage in academic libraries in Ghana: evidence from Koforidua Polytechnic & All Nations University College, Ghana. The study was a quantitative approach using questionnaire to gather data and information. A valid response rate of 58.5% was assumed. SPSS…

  8. Calcium detection in secretion granules of avian oviduct by scanning electron microscopy (SEM) and energy-dispersive X-ray microanalysis (EDX)

    International Nuclear Information System (INIS)

    Makita, T.; Hatsuoka, M.; Sugi, Y.

    1983-01-01

    Secretion granules in the shell gland, isthmus, and albumin-secreting region of the hen oviduct were analyzed with WET-scanning electron microscopy (SEM) and EDX, a combination of wide-angle backscattered electron detector (BED) and energy-dispersive X-ray microanalyzer (EDX). Glutaraldehyde-fixed but unhydrated, unstained, and uncoated samples were analyzed; Ca was localized in all secretion granules in all three sections of the hen oviduct studied

  9. Utilization of Electronic Information Resources by Undergraduate Students of University of Ibadan: A Case Study of Social Sciences and Education

    Science.gov (United States)

    Owolabi, Sola; Idowu, Oluwafemi A.; Okocha, Foluke; Ogundare, Atinuke Omotayo

    2016-01-01

    The study evaluated utilization of electronic information resources by undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan. The study adopted a descriptive survey design with a study population of 1872 undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan, from which a…

  10. Shaping the Electronic Library--The UW-Madison Approach.

    Science.gov (United States)

    Dean, Charles W., Ed.; Frazier, Ken; Pope, Nolan F.; Gorman, Peter C.; Dentinger, Sue; Boston, Jeanne; Phillips, Hugh; Daggett, Steven C.; Lundquist, Mitch; McClung, Mark; Riley, Curran; Allan, Craig; Waugh, David

    1998-01-01

    This special theme section describes the University of Wisconsin-Madison's experience building its Electronic Library. Highlights include integrating resources and services; the administrative framework; the public electronic library, including electronic publishing capability and access to World Wide Web-based and other electronic resources;…

  11. Controlling user access to electronic resources without password

    Science.gov (United States)

    Smith, Fred Hewitt

    2017-08-22

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes obtaining an image from a communication device of a user. An individual and a landmark are identified within the image. Determinations are made that the individual is the user and that the landmark is a predetermined landmark. Access to a restricted computing resource is granted based on the determining that the individual is the user and that the landmark is the predetermined landmark. Other embodiments are disclosed.

  12. The use of quality benchmarking in assessing web resources for the dermatology virtual branch library of the National electronic Library for Health (NeLH).

    Science.gov (United States)

    Kamel Boulos, M N; Roudsari, A V; Gordon, C; Muir Gray, J A

    2001-01-01

    In 1998, the U.K. National Health Service Information for Health Strategy proposed the implementation of a National electronic Library for Health to provide clinicians, healthcare managers and planners, patients and the public with easy, round the clock access to high quality, up-to-date electronic information on health and healthcare. The Virtual Branch Libraries are among the most important components of the National electronic Library for Health. They aim at creating online knowledge based communities, each concerned with some specific clinical and other health-related topics. This study is about the envisaged Dermatology Virtual Branch Libraries of the National electronic Library for Health. It aims at selecting suitable dermatology Web resources for inclusion in the forthcoming Virtual Branch Libraries after establishing preliminary quality benchmarking rules for this task. Psoriasis, being a common dermatological condition, has been chosen as a starting point. Because quality is a principal concern of the National electronic Library for Health, the study includes a review of the major quality benchmarking systems available today for assessing health-related Web sites. The methodology of developing a quality benchmarking system has been also reviewed. Aided by metasearch Web tools, candidate resources were hand-selected in light of the reviewed benchmarking systems and specific criteria set by the authors. Over 90 professional and patient-oriented Web resources on psoriasis and dermatology in general are suggested for inclusion in the forthcoming Dermatology Virtual Branch Libraries. The idea of an all-in knowledge-hallmarking instrument for the National electronic Library for Health is also proposed based on the reviewed quality benchmarking systems. Skilled, methodical, organized human reviewing, selection and filtering based on well-defined quality appraisal criteria seems likely to be the key ingredient in the envisaged National electronic Library for

  13. Automated scanning electron microscopy and x-ray microanalysis for in situ quantification of gadolinium deposits in skin

    International Nuclear Information System (INIS)

    Thakral, Charu; Abraham, Jerrold L.

    2007-01-01

    Gadolinium (Gd) has been identified as a possible causative agent of an emerging cutaneous and systemic fibrosing disorder, nephrogenic systemic fibrosis (NSF), which can cause serious disability and even death. To date, there are only two known associations with this disorder - renal insufficiency and Gd enhanced magnetic resonance imaging (MRI). We developed an automated quantitative scanning electron microscopy (SEM) and Energy dispersive x-ray spectroscopy (EDS) method for Gd in tissue of NSF patients. Freshly cut paraffin block surfaces examined using the variable pressure mode under standardized conditions and random search of the tissue area allow in situ detection and semiquantitative morphometric (volumetric) analysis of insoluble higher atomic number features using backscattered electron imaging. We detected Gd ranging from 1 to 2270 cps/mm 2 in 57 cutaneous biopsies of NSF. Gd was associated with P, Ca, and usually Na in tissue deposits. Our method reproducibly determines the elemental composition, relative concentration, and spatial distribution of detected features within the tissue. However, we cannot detect features below our spatial resolution, nor concentrations below the detection limit of our SEM/EDS system. The findings confirm transmetallation and release of toxic Gd ions in NSF and allow dose-response analysis at the histologic level. (author)

  14. The uniformity study of non-oxide thin film at device level using electron energy loss spectroscopy

    Science.gov (United States)

    Li, Zhi-Peng; Zheng, Yuankai; Li, Shaoping; Wang, Haifeng

    2018-05-01

    Electron energy loss spectroscopy (EELS) has been widely used as a chemical analysis technique to characterize materials chemical properties, such as element valence states, atoms/ions bonding environment. This study provides a new method to characterize physical properties (i.e., film uniformity, grain orientations) of non-oxide thin films in the magnetic device by using EELS microanalysis on scanning transmission electron microscope. This method is based on analyzing white line ratio of spectra and related extended energy loss fine structures so as to correlate it with thin film uniformity. This new approach can provide an effective and sensitive method to monitor/characterize thin film quality (i.e., uniformity) at atomic level for thin film development, which is especially useful for examining ultra-thin films (i.e., several nanometers) or embedded films in devices for industry applications. More importantly, this technique enables development of quantitative characterization of thin film uniformity and it would be a remarkably useful technique for examining various types of devices for industrial applications.

  15. There is a Relationship between Resource Expenditures and Reference Transactions in Academic Libraries. A Review of: Dubnjakovic, A. (2012. Electronic resource expenditure and the decline in reference transaction statistics in academic libraries. Journal of Academic Librarianship, 38(2, 94-100. doi:10.1016/j.acalib.2012.01.001

    Directory of Open Access Journals (Sweden)

    Annie M. Hughes

    2013-03-01

    Full Text Available Objective – To provide an analysis of the impact of expenditures on electronic resourcesand gate counts on the increase or decrease in reference transactions.Design – Analysis of results of existing survey data from the National Center for Educational Statistics (NCES 2006 Academic Library Survey(ALS.Setting – Academic libraries in the United States.Subjects – 3925 academic library respondents.Methods – The author chose to use survey data collected from the 2006 ALS conducted bythe NCES. The survey included data on various topics related to academic libraries, but in the case of this study, the author chose to analyze three of the 193 variables included. The three variables: electronic books expenditure, computer hardware and software, and expenditures on bibliographic utilities, were combined into one variable called electronic resource expenditure. Gate counts were also considered as a variable. Electronic resource expenditure was also split as a variable into three groups: low, medium, and high. Multiple regression analysis and general linear modeling, along with tests of reliability, were employed. Main Results – The author determined that low, medium, and high spenders with regard to electronic resources exhibited differences in gate counts, and gate counts have an effect on reference transactions in any given week. Gate counts tend to not have much of an effect on reference transactions for the higher spenders, and higher spenders tend to have a higher number of reference transactions overall. Low spenders have lower gate counts and also a lower amount of reference transactions.Conclusion – The findings from this study show that academic libraries spending more on electronic resources also tend to have an increase with regard to reference transactions. The author also concludes that library spaces are no longer the determining factor with regard to number of reference transactions. Spending more on electronic resources is

  16. Electronic resources access and usage among the postgraduates of ...

    African Journals Online (AJOL)

    ... and usage among the postgraduates of a Nigerian University of Technology. ... faced by postgraduates in using e-resources include takes too much time to find, ... Resources, Access, Use, Postgraduat, Students, University, Technology, Nigeria ... By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  17. Characterization of the calcification of cardiac valve bioprostheses by environmental scanning electron microscopy and vibrational spectroscopy.

    Science.gov (United States)

    Delogne, Christophe; Lawford, Patricia V; Habesch, Steven M; Carolan, Vikki A

    2007-10-01

    Bioprosthetic heart valve tissue and associated calcification were studied in their natural state, using environmental scanning electron microscopy (ESEM). Energy dispersive X-ray micro-analysis, X-ray diffraction, Fourier-transform infrared and Raman spectroscopy were used to characterize the various calcific deposits observed with ESEM. The major elements present in calcified valves were also analyzed by inductively coupled plasma-optical emission spectroscopy. To better understand the precursor formation of the calcific deposits, results from the elemental analyses were statistically correlated. ESEM revealed the presence of four broad types of calcium phosphate crystal morphology. In addition, two main patterns of organization of calcific deposits were observed associated with the collagen fibres. Energy dispersive X-ray micro-analysis identified the crystals observed by ESEM as salts containing mainly calcium and phosphate with ratios from 1.340 (possibly octacalcium phosphate, which has a Ca/P ratio of 1.336) to 2.045 (possibly hydroxyapatite with incorporation of carbonate and metal ion contaminants, such as silicon and magnesium, in the crystal lattice). Raman and fourier-transform infrared spectroscopy also identified the presence of carbonate and the analyses showed spectral features very similar to a crystalline hydroxyapatite spectrum, also refuting the presence of precursor phases such as beta-tricalcium phosphate, octacalcium phosphate and dicalcium phosphate dihydrate. The results of this study raised the possibility of the presence of precursor phases associated with the early stages of calcification.

  18. Th-U-Pb{sub T} dating by electron probe microanalysis, Part I. Monazite: analytical procedures and data treatment

    Energy Technology Data Exchange (ETDEWEB)

    Vlach, Silvio Roberto Farias [Universidade de Sao Paulo (USP), Sao Carlos, SP (Brazil). Inst. de Geociencias. Dept. de Mineralogia e Geotectonica], e-mail: srfvlach@usp.br

    2010-03-15

    Dating methodology by the electron probe microanalyser (EPMA) of (Th, U)-bearing minerals, highlighting monazite, acquired greater than ever importance in literature, particularly due to its superior spatial resolution, as well as versatility, which allow correlating petrological processes at times registered only in micro-scales in minerals and rocks with absolute ages. Although the accuracy is inferior to the one achieved with conventional isotopic methods in up to an order of magnitude, EPMA is the instrument that allows the best spatial resolution, reaching a few {mu}m{sup 3} in some conditions. Quantification of minor and trace elements with suitable precision and accuracy involves the own instrumental and analytical set-ups and data treatment strategies, significantly more rigorous when compared with those applied in conventional analyses. Th-U-Pb{sub T} dating is an example of these cases. Each EPMA is a unique machine as for its instrumental characteristics and respective automation system. In such a way, analytical procedures ought to be adjusted for laboratory specific cities. The analytical strategies and data treatment adopted in the Electronic Microprobe Laboratory from Instituto de Geociencias of Universidade de Sao Paulo, Brazil, with a JEOL JXA8600S EPMA, and a ThermoNoran-Voyager 4.3 automation system, are presented and compared with the ones used in other laboratories. The influence of instrumental factors and spectral overlaps on Th, U, and Pb quantification is discussed. Applied procedures to interference correction, error propagation, data treatment, and final chemical age presentation as well as to sampling and analyses are emphasized. Some typical applications are discussed, drawing attention to the most relevant aspects of electron microprobe dating. (author)

  19. Electronic Safety Resource Tools -- Supporting Hydrogen and Fuel Cell Commercialization

    Energy Technology Data Exchange (ETDEWEB)

    Barilo, Nick F.

    2014-09-29

    The Pacific Northwest National Laboratory (PNNL) Hydrogen Safety Program conducted a planning session in Los Angeles, CA on April 1, 2014 to consider what electronic safety tools would benefit the next phase of hydrogen and fuel cell commercialization. A diverse, 20-person team led by an experienced facilitator considered the question as it applied to the eight most relevant user groups. The results and subsequent evaluation activities revealed several possible resource tools that could greatly benefit users. The tool identified as having the greatest potential for impact is a hydrogen safety portal, which can be the central location for integrating and disseminating safety information (including most of the tools identified in this report). Such a tool can provide credible and reliable information from a trustworthy source. Other impactful tools identified include a codes and standards wizard to guide users through a series of questions relating to application and specific features of the requirements; a scenario-based virtual reality training for first responders; peer networking tools to bring users from focused groups together to discuss and collaborate on hydrogen safety issues; and a focused tool for training inspectors. Table ES.1 provides results of the planning session, including proposed new tools and changes to existing tools.

  20. Electron microscopy and microanalysis of uranium phases in primary ores, Eocene and Miocene of south Texas

    International Nuclear Information System (INIS)

    Liang, L.C.; Price, J.G.; Bobeck, P.

    1984-01-01

    Two contrasting types of roll-front uranium deposits occur in south Texas. In the barrier-bar sands of the Eocene Jackson Group, organic matter was essential to uranium reduction, whereas in the fluvial sands of the Miocene Oakville Formation, epigenetic pyrite was the reductant. In a sample of reduced Oakville ore, a uranium phase with grains ranging in diameter from < 1 to 20μm was recognized by SEM backscattered-electron imaging and wavelength-dispersive spectrometer (WDS) elemental-dot mapping. Quantitative microprobe analyses indicated that the phase is a uranium-calcium silicate-phosphate with molar Ca/P approximately equal to 1.0, U/P equal to 2.8 +/- 0.4 (n = 27), and U/Si approaching 1.0 in samples uncontaminated with quartz, feldspar, or clay minerals. Highest uranium content is 59%. Oakville ore is typically easy to leach by in-situ methods. Jackson ore contains 2 uranium phases. Sulfur-rich organic matter contains 4.1 +/- 1.6% uranium (n = 27). Although individual grains of a possible uranium mineral within the organic matter are too small to be resolved by electron imaging, a consistent molar U/Fe (0.5 +/- 0.1) suggests a uranium-iron oxide phase. Alternatively, uranium is adsorbed by or otherwise bound to the organic matter. The second phase is a uranium-calcium silicate-phosphate that differs from the Oakville ore. Molar Ca/P equals 0.8 +/- 0.2 (n = 13), and U/P equals 4.7 +/- 0.4. Small grain size (generally less than 1 μm) prevented analysis of samples uncontaminated with quartz and pyrite. The grain with highest uranium content (43%) has U/Si equal to 0.34. Jackson ore is less favorable for in-situ leaching than Oakville ore in part because the organic-associated uranium is difficult to extract

  1. EFFECTIVE ELECTRONIC TUTORIAL

    Directory of Open Access Journals (Sweden)

    Andrei A. Fedoseev

    2014-01-01

    Full Text Available The article analyzes effective electronic tutorials creation and application based on the theory of pedagogy. Herewith the issues of necessary electronic tutorial functional, ways of the educational process organization with the use of information and communication technologies and the logistics of electronic educational resources are touched upon. 

  2. Renewable energy resources

    DEFF Research Database (Denmark)

    Ellabban, Omar S.; Abu-Rub, Haitham A.; Blaabjerg, Frede

    2014-01-01

    Electric energy security is essential, yet the high cost and limited sources of fossil fuels, in addition to the need to reduce greenhouse gasses emission, have made renewable resources attractive in world energy-based economies. The potential for renewable energy resources is enormous because...... they can, in principle, exponentially exceed the world's energy demand; therefore, these types of resources will have a significant share in the future global energy portfolio, much of which is now concentrating on advancing their pool of renewable energy resources. Accordingly, this paper presents how...... renewable energy resources are currently being used, scientific developments to improve their use, their future prospects, and their deployment. Additionally, the paper represents the impact of power electronics and smart grid technologies that can enable the proportionate share of renewable energy...

  3. Preference and Use of Electronic Information and Resources by Blind/Visually Impaired in NCR Libraries in India

    Directory of Open Access Journals (Sweden)

    Shailendra Kumar

    2013-06-01

    Full Text Available This paper aims to determine the preference and use of electronic information and resources by blind/visually impaired users in the leading National Capital Region (NCR libraries of India. Survey methodology has been used as the basic research tool for data collection with the help of questionnaires. The 125 in total users surveyed in all the five libraries were selected randomly on the basis of willingness of the users with experience of working in digital environments to participate in the survey. The survey results were tabulated and analyzed with descriptive statistics methods using Excel software and 'Stata version 11'. The findings reveal that ICT have a positive impact in the lives of people with disabilities as it helps them to work independently and increases the level of confidence among them. The Internet is the most preferred medium of access to information among the majority of blind/visually impaired users. The 'Complexity of content available on the net' is found as the major challenge faced during Internet use by blind users of NCR libraries. 'Audio books on CDs/DVDs and DAISY books' are the most preferred electronic resources among the majority of blind/visually impaired users. This study will help the library professionals and organizations/institutions serving people with disabilities to develop effective library services for blind/visually impaired users in the digital environment on the basis of findings on information usage behavior in the study.

  4. Transmission electron microscopy for elucidating the impact of silver-based treatments (ionic silver versus nanosilver-containing coating) on the model yeast Saccharomyces cerevisiae

    Energy Technology Data Exchange (ETDEWEB)

    Despax, B; Saulou, C; Raynaud, P [Universite de Toulouse, UPS, INPT, LAPLACE, 118 route de Narbonne, F-31062 Toulouse cedex 9 (France); Datas, L [Universite de Toulouse, UPS, INPT, CIRIMAT, 118 route de Narbonne, F-31062 Toulouse cedex 9 (France); Mercier-Bonin, M [Universite de Toulouse, INSA, UPS, INP, LISBP, 135 Avenue de Rangueil, F-31077 Toulouse (France)

    2011-04-29

    After exposure to ionic silver or nanosilver-containing plasma coating, the same visual aspect of scanning transmission electron microscopy (STEM) images was observed for the model yeast Saccharomyces cerevisiae. The main common feature was the presence of electron-dense nodules all over the cell. However, high resolution TEM (HRTEM), STEM, energy dispersive x-ray microanalysis spectroscopy (EDS) and electron microdiffraction revealed some striking differences. Regarding ionic silver exposure, the formation of electron-dense nodules was related to the Ag{sup +} reactivity towards sulfur-containing compounds to form clusters with Ag{sub 2}S-like structures, together with the production of a few silver nanocrystals, mainly at the cell wall periphery. For nanosilver-based treatment, some sulfur-containing silver clusters preferentially located at the cell wall periphery were detected, together with nodules composed of silver, sulfur and phosphorus all over the cell. In both silver-based treatments, nitrogen and silver signals overlapped, confirming the affinity of silver entities for proteinaceous compounds. Moreover, in the case of nanosilver, interactions of silver with phosphorus-containing subcellular structures were indicated.

  5. A useful and non-invasive microanalysis method for dental restoration materials

    International Nuclear Information System (INIS)

    Hosoki, M.; Satsuma, T.; Nishigawa, K.; Takeuchi, H.; Asaoka, K.

    2012-01-01

    Highlights: ► This method for the microanalysis of dental alloys is beneficial for patients with allergies to dental materials. ► This metal sample is easy to mail it for inspection at specialist institutes. ► This method can be also be used in general dental clinics. - Abstract: The elemental analysis of intraoral dental restorations provides considerable information for the treatment of dental metal allergy. Elemental analyses require specific instruments and complicated procedures, so this examination is not commonly carried out in private dental clinics. We describe a novel, simple and useful micro-analytical method for dental metal restorations. Micro metal dust was obtained by polishing the surface of restorative metal material with an unused silicone point (SUPER-SNAP). The metal dust on the silicone point was then rubbed onto adhesive tape, and this tape was covered with polyethylene film. The amount of metal dust material was <20 μg. An energy dispersive X-ray fluorescence spectrometer was used to carry out the elementary analysis of the metal dust on the polyethylene film. Three types of dental metal alloy materials of known components were examined. The results of elementary analyses were compared with the specifications provided by the manufacturer. The same procedure was carried out for three dental metal restorations of an adult female volunteer in vivo. The results of elemental analyses for five alloy materials exactly matched the product specification. Three metal samples obtained from intraoral restoration were also available for elemental analyses. The distinct advantage of this method is that it enables sample extraction without an invasive effect for the restoration. The metal sample is in a polyethylene film, so it is easy to mail it for inspection at specialist institutes yet it can be also be used in general dental clinics.

  6. A useful and non-invasive microanalysis method for dental restoration materials

    Energy Technology Data Exchange (ETDEWEB)

    Hosoki, M., E-mail: hosoki@tokushima-u.ac.jp [Department of Fixed Prosthodontics, Institute of Health Biosciences, University of Tokushima Graduate School, 3-18-15 Kuramoto-cho, Tokushima 770-8504 (Japan); Satsuma, T.; Nishigawa, K.; Takeuchi, H. [General Dentistry, Tokushima University Hospital, 3-18-15 Kuramoto-cho, Tokushima 770-8504 (Japan); Asaoka, K. [Department of Biomaterials and Bioengineering, Institute of Health Biosciences, University of Tokushima Graduate School, 3-18-15 Kuramoto-cho, Tokushima 770-8504 (Japan)

    2012-12-01

    Highlights: Black-Right-Pointing-Pointer This method for the microanalysis of dental alloys is beneficial for patients with allergies to dental materials. Black-Right-Pointing-Pointer This metal sample is easy to mail it for inspection at specialist institutes. Black-Right-Pointing-Pointer This method can be also be used in general dental clinics. - Abstract: The elemental analysis of intraoral dental restorations provides considerable information for the treatment of dental metal allergy. Elemental analyses require specific instruments and complicated procedures, so this examination is not commonly carried out in private dental clinics. We describe a novel, simple and useful micro-analytical method for dental metal restorations. Micro metal dust was obtained by polishing the surface of restorative metal material with an unused silicone point (SUPER-SNAP). The metal dust on the silicone point was then rubbed onto adhesive tape, and this tape was covered with polyethylene film. The amount of metal dust material was <20 {mu}g. An energy dispersive X-ray fluorescence spectrometer was used to carry out the elementary analysis of the metal dust on the polyethylene film. Three types of dental metal alloy materials of known components were examined. The results of elementary analyses were compared with the specifications provided by the manufacturer. The same procedure was carried out for three dental metal restorations of an adult female volunteer in vivo. The results of elemental analyses for five alloy materials exactly matched the product specification. Three metal samples obtained from intraoral restoration were also available for elemental analyses. The distinct advantage of this method is that it enables sample extraction without an invasive effect for the restoration. The metal sample is in a polyethylene film, so it is easy to mail it for inspection at specialist institutes yet it can be also be used in general dental clinics.

  7. Cryo-Scanning Electron Microscopy (SEM) and Scanning Transmission Electron Microscopy (STEM)-in-SEM for Bio- and Organo-Mineral Interface Characterization in the Environment.

    Science.gov (United States)

    Wille, Guillaume; Hellal, Jennifer; Ollivier, Patrick; Richard, Annie; Burel, Agnes; Jolly, Louis; Crampon, Marc; Michel, Caroline

    2017-12-01

    Understanding biofilm interactions with surrounding substratum and pollutants/particles can benefit from the application of existing microscopy tools. Using the example of biofilm interactions with zero-valent iron nanoparticles (nZVI), this study aims to apply various approaches in biofilm preparation and labeling for fluorescent or electron microscopy and energy dispersive X-ray spectrometry (EDS) microanalysis for accurate observations. According to the targeted microscopy method, biofilms were sampled as flocs or attached biofilm, submitted to labeling using 4',6-diamidino-2-phenylindol, lectins PNA and ConA coupled to fluorescent dye or gold nanoparticles, and prepared for observation (fixation, cross-section, freezing, ultramicrotomy). Fluorescent microscopy revealed that nZVI were embedded in the biofilm structure as aggregates but the resolution was insufficient to observe individual nZVI. Cryo-scanning electron microscopy (SEM) observations showed nZVI aggregates close to bacteria, but it was not possible to confirm direct interactions between nZVI and cell membranes. Scanning transmission electron microscopy in the SEM (STEM-in-SEM) showed that nZVI aggregates could enter the biofilm to a depth of 7-11 µm. Bacteria were surrounded by a ring of extracellular polymeric substances (EPS) preventing direct nZVI/membrane interactions. STEM/EDS mapping revealed a co-localization of nZVI aggregates with lectins suggesting a potential role of EPS in nZVI embedding. Thus, the combination of divergent microscopy approaches is a good approach to better understand and characterize biofilm/metal interactions.

  8. NENIMF: Northeast National Ion Microprobe Facility - A Multi-User Facility for SIMS Microanalysis

    Science.gov (United States)

    Layne, G. D.; Shimizu, N.

    2002-12-01

    The MIT-Brown-Harvard Regional Ion Microprobe Facility was one of the earliest multi-user facilities enabled by Dan Weill's Instrumentation and Facilities Program - and began with the delivery of a Cameca IMS 3f ion microprobe to MIT in 1978. The Northeast National Ion Microprobe Facility (NENIMF) is the direct descendant of this original facility. Now housed at WHOI, the facility incorporates both the original IMS 3f, and a new generation, high transmission-high resolution instrument - the Cameca IMS 1270. Purchased with support from NSF, and from a consortium of academic institutions in the Northeast (The American Museum of Natural History, Brown University, The Lamont-Doherty Earth Observatory, MIT, Rensselaer Polytechnic Institute, WHOI) - this latest instrument was delivered and installed during 1996. NENIMF continues to be supported by NSF EAR I&F as a multi-user facility for geochemical research. Work at NENIMF has extended the original design strength of the IMS 1270 for microanalytical U-Pb zircon geochronology to a wide variety of novel and improved techniques for geochemical research. Isotope microanalysis for studies in volcanology and petrology is currently the largest single component of facility activity. This includes the direct measurement of Pb isotopes in melt inclusions, an application developed at NENIMF, which is making an increasingly significant contribution to our understanding of basalt petrogenesis. This same technique has also been extended to the determination of Pb isotopes in detrital feldspar grains, for the study of sedimentary provenance and tectonics of the Himalayas and other terrains. The determination of δ11B in volcanic melt inclusions has also proven to be a powerful tool in the modeling of subduction-related magmatism. The recent development of δ34S and δ37Cl determination in glasses is being applied to studies of the behavior of these volatile elements in both natural and experimental systems. Other recent undertakings

  9. Library usage patterns in the electronic information environment. Electronic journals, Use studies, Libraries, Medical libraries

    Directory of Open Access Journals (Sweden)

    B. Franklin

    2004-01-01

    Full Text Available This paper examines the methodology and results from Web-based surveys of more than 15,000 networked electronic services users in the United States between July 1998 and June 2003 at four academic health sciences libraries and two large main campus libraries serving a variety of disciplines. A statistically valid methodology for administering simultaneous Web-based and print-based surveys using the random moments sampling technique is discussed and implemented. Results from the Web-based surveys showed that at the four academic health sciences libraries, there were approximately four remote networked electronic services users for each in-house user. This ratio was even higher for faculty, staff, and research fellows at the academic health sciences libraries, where more than five remote users for each in-house user were recorded. At the two main libraries, there were approximately 1.3 remote users for each in-house user of electronic information. Sponsored research (grant funded research accounted for approximately 32% of the networked electronic services activity at the health sciences libraries and 16% at the main campus libraries. Sponsored researchers at the health sciences libraries appeared to use networked electronic services most intensively from on-campus, but not from in the library. The purpose of use for networked electronic resources by patrons within the library is different from the purpose of use of those resources by patrons using the resources remotely. The implications of these results on how librarians reach decisions about networked electronic resources and services are discussed.

  10. Electron microscopy and auger spectroscopy study of the wetting of the grain boundaries in the systems Mo-Pb, Mo-Sn, Mo-Ni and Ni-Pb

    International Nuclear Information System (INIS)

    Charai, A.; Kutcherinenko, I.; Priester, L.; Penisson, J.M.; Pontikis, V.; Wolski, K.; Vystavel, T.

    2002-01-01

    Understanding the mechanism of the intergranular penetration of a liquid phase into a metallic solid is an important problem. The structural and chemical characterization of nano-metric films at grain boundaries is now possible by using high resolution electron microscopy associated with X-ray micro-analysis, electron energy loss spectroscopy and Auger spectroscopy. In order to study this problem, two different classes of model materials were selected according to their crystallographic structure: a bcc metal (molybdenum) and an fcc one (nickel). The wetting element was either lead or tin or nickel. In a first approach, the metallic matrix was polycrystalline. The conditions in which the liquid phase penetrates into the grain boundaries were studied by using special preparation and observation techniques. In particular, the use of a Focused Ion Beam microscope (FIB) allowed the preparation of thin foils located very precisely inside the matrix as well as multi-scale observations. These specimens were further observed in electron microscopy with a very high resolution. (authors)

  11. Non-matrix corrected organic sulfur determination by energy dispersive X-ray spectroscopy for western Kentucky coals and residues

    International Nuclear Information System (INIS)

    Clark, C.P.; Freeman, G.B.; Hower, J.C.

    1984-01-01

    A method for non-matrix corrected organic sulfur analysis by energy dispersive X-ray spectroscopy has been developed using petroleum coke standards. Typically, electron beam microanalysis is a rapid, nondestructive analytical technique to quantitatively measure organic sulfur in coal. The results show good correlation to ASTM values for numerous well characterized coals with a wide range in total and pyritic sulfur content. This direct analysis is capable of reducing error commonly associated with the present ASTM method which relies on an indirect measure of organic sulfur by difference. The precision of the organic sulfur values determined in the present study is comparable to that obtained by ZAF matrix corrected microanalysis. The energy dispersive microanalysis is capable of measuring micro as well as bulk organic sulfur levels

  12. Method for separation of Cs from acid solution dissolving radionuclides and microanalysis of solution with ICP-AES

    International Nuclear Information System (INIS)

    Kanazawa, Toru; Hidaka, Akihide; Kudo, Tamotsu; Nakamura, Takehiko; Fuketa, Toyoshi

    2004-06-01

    The VEGA (Verification Experiments of radionuclides Gas/Aerosol release) program is being performed at JAERI to understand mechanisms of radionuclides release from irradiated fuel during severe accidents. As a part of evaluation in the program, the mass balances of released and deposited FP (Fission Products) onto the test apparatus are estimated from gamma ray measurement for acid solution leached from the apparatus, but short-life nuclides are difficult to be measured because those in the VEGA fuel have been mostly depleted due to cooling for several years. Moreover, the radionuclides without emitting gamma rays and very small quantity of elements cannot be quantified by gamma ray measurement. Therefore, a microanalysis by ICP-AES (Inductively Coupled Plasma - Atomic Emission Spectrometry) for the acid solution leached from VEGA apparatuses is being applied to evaluate the released and deposited masses for those elements. Since Cs-134 and -137, which are major FP dissolved in the solution, have high intensity of gamma ray spectrum, they have to be removed from the solution before the microanalysis in order to avoid contamination of ICP system and to decrease exposure to gamma ray. In this report, methods for separation of Cs from acid solution were reviewed and the applicability of them to the ICP-AES analysis was discussed. The method for Cs separation using the inorganic ion exchanger, AMP (Ammonium Molybdate Phosphate) was applied to the solutions of cold and hot test and the effectiveness was examined. The results showed that more than 99.9% of Cs could be removed from the test solutions, and once removed Sb by AMP was recovered by using a complexing agent such as citric acid. Next, the method was applied to an acid solution leached from VEGA-3 apparatus, and ICP-AES analysis was performed for it. The analysis showed that amount of U, Sr and Zr were successfully quantified. Most of elements to be analyzed were measurable except for Sb, Ag and Sn, although

  13. Electronic resources of the rare books and valuable editions department of the Central Scientific Library of the V.N. Karazin Kharkiv National University: open access for research

    Directory of Open Access Journals (Sweden)

    І. К. Журавльова

    2014-12-01

    Full Text Available The article describes tasks that electronic collections of rare books fulfill: broad access for readers to rare and valuable editions providing, preservation of ensuring of the original. On the example of the electronic collection of the Central Scientific Library of the V.N. Karazin Kharkiv National University – «eScriptorium: electronic archive of rare books and manuscripts for research and education» the possibility of the full-text resources of the valuable editions using is shown. The principles of creation, structure, chronological frameworks, directions of adding the documents to the archive are represented. The perspectives of the project development are outlined as well as examples of the digital libraries of the European countries and Ukraine are provided, the actual task of preserving the originals of the rare books of the country is raised, the innovative approaches to serving users with electronic resources are considered. The evidences of cooperation of the Central Scientific Library of the V.N. Karazin Kharkiv National University with the largest world digital libraries: World Digital Library and Europeana are provided.

  14. Attempt to assess the infiltration of enamel made with experimental preparation using a scanning electron microscope.

    Science.gov (United States)

    Skucha-Nowak, Małgorzata

    2015-01-01

    The resin infiltration technique, a minimally invasive method, involves the saturation, strengthening, and stabilization of demineralized enamel by a mixture of polymer resins without the need to use rotary tools or the risk of losing healthy tooth structures. To design and synthesize an experimental infiltrant with potential bacteriostatic properties.To compare the depth of infiltration of the designed experimental preparation with the infiltrant available in the market using a scanning electron microscope. Composition of the experimental infiltrant was established after analysis of 1H NMR spectra of the commercially available compounds that can penetrate pores of demineralized enamel. As the infiltrant should have bacteriostatic features by definition, an addition of 1% of monomer containing metronidazole was made. Thirty extracted human teeth were soaked in an acidic solution, which was to provide appropriate conditions for demineralization of enamel. Afterward, each tooth was divided along the coronal-root axis into two zones. One zone had experimental preparation applied to it (the test group), while the other had commercially available Icon (the control group). The teeth were dissected along the long axis and described above underwent initial observation with use of a Hitachi S-4200 scanning electron microscope. It was found that all samples contained only oxygen and carbon, regardless of the concentration of additions introduced into them. The occurrence of carbon is partially because it is a component of the preparation in question and partially because of sputtering of the sample with it. Hydrogen is also a component of the preparation, as a result of its phase composition; however, it cannot be detected by the EDS method. SEM, in combination with X-ray microanalysis, does not allow one to explicitly assess the depth of penetration of infiltration preparations into enamel.In order to assess the depth of penetration of infiltration preparations with use of

  15. Electronic tracking of human resource skills and knowledge, just in time training, manageable due diligence

    Energy Technology Data Exchange (ETDEWEB)

    Kolodziej, M.A. [Quick Test International Inc., (Canada). Canadian Technology Human Resource Board; Baker, O. [KeySpan Energy Canada, Calgary, AB (Canada)

    2001-06-01

    KeySpan Energy Canada is in the process of obtaining recognition of various occupational profiles including pipeline operators, inspectors, and field and plant operators from various certifying organizations. The process of allowing individuals to obtain certification is recognized by Canadian Technology Human Resources Board as a step towards national standards for technologists and technicians. Proven competency is a must for workers in todays oil industry in response to increasingly stringent government safety regulations, environmental concerns and high public scrutiny. Quick Test international Inc. has developed a management tool in collaboration with end users at KeySpan Energy Canada. It is an electronic, Internet based competency tool for tracking personal competencies and maintaining continued competency. Response to the tool has been favourable. 2 refs., 4 figs.

  16. Synchrotron radiation induced x-ray micro analysis: A realistic alternative for electron- and ion beam microscopy?

    Energy Technology Data Exchange (ETDEWEB)

    Janssens, K.; Adams, F. [Universitaire Instelling Antwerpen, Antwerp (Belgium). Dept. of Chemistry; Rivers, M.L.; Jones, K.W. [Brookhaven National Lab., Upton, NY (United States)

    1992-10-01

    Synchrotron Radiation induced X-ray micro Fluorescence analysis ({mu}-SRXRF) is compared with more conventional microanalytical techniques such as Secondary Ion Microscopy (SIMS) and Electron Probe X-ray Microanalysis (EPXMA) for two typical microanalytical applications. SRXRF and EPXMA are employed for the analysis of individual particles, showing the complementary character of both techniques. By means of element mapping of trace constituents in a heterogeneous feldspar, the strong and weak points of SRXRF in comparison to EPXMA and SIMS are illustrated. The most striking difference between SRXRF and the other two microanalytical methods is the ability of SRXRF to probe deep into the investigated Material, whereas SIMS and EPXMA only investigate the upper surface of the material. The possibilities of SRXRF at third generation synchrotron rings is also briefly discussed.

  17. Synchrotron radiation induced x-ray micro analysis: A realistic alternative for electron- and ion beam microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Janssens, K.; Adams, F. (Universitaire Instelling Antwerpen, Antwerp (Belgium). Dept. of Chemistry); Rivers, M.L.; Jones, K.W. (Brookhaven National Lab., Upton, NY (United States))

    1992-01-01

    Synchrotron Radiation induced X-ray micro Fluorescence analysis ([mu]-SRXRF) is compared with more conventional microanalytical techniques such as Secondary Ion Microscopy (SIMS) and Electron Probe X-ray Microanalysis (EPXMA) for two typical microanalytical applications. SRXRF and EPXMA are employed for the analysis of individual particles, showing the complementary character of both techniques. By means of element mapping of trace constituents in a heterogeneous feldspar, the strong and weak points of SRXRF in comparison to EPXMA and SIMS are illustrated. The most striking difference between SRXRF and the other two microanalytical methods is the ability of SRXRF to probe deep into the investigated Material, whereas SIMS and EPXMA only investigate the upper surface of the material. The possibilities of SRXRF at third generation synchrotron rings is also briefly discussed.

  18. Synchrotron radiation induced x-ray micro analysis: A realistic alternative for electron- and ion beam microscopy?

    International Nuclear Information System (INIS)

    Janssens, K.; Adams, F.

    1992-01-01

    Synchrotron Radiation induced X-ray micro Fluorescence analysis (μ-SRXRF) is compared with more conventional microanalytical techniques such as Secondary Ion Microscopy (SIMS) and Electron Probe X-ray Microanalysis (EPXMA) for two typical microanalytical applications. SRXRF and EPXMA are employed for the analysis of individual particles, showing the complementary character of both techniques. By means of element mapping of trace constituents in a heterogeneous feldspar, the strong and weak points of SRXRF in comparison to EPXMA and SIMS are illustrated. The most striking difference between SRXRF and the other two microanalytical methods is the ability of SRXRF to probe deep into the investigated Material, whereas SIMS and EPXMA only investigate the upper surface of the material. The possibilities of SRXRF at third generation synchrotron rings is also briefly discussed

  19. The Biomedical Resource Ontology (BRO) to enable resource discovery in clinical and translational research.

    Science.gov (United States)

    Tenenbaum, Jessica D; Whetzel, Patricia L; Anderson, Kent; Borromeo, Charles D; Dinov, Ivo D; Gabriel, Davera; Kirschner, Beth; Mirel, Barbara; Morris, Tim; Noy, Natasha; Nyulas, Csongor; Rubenson, David; Saxman, Paul R; Singh, Harpreet; Whelan, Nancy; Wright, Zach; Athey, Brian D; Becich, Michael J; Ginsburg, Geoffrey S; Musen, Mark A; Smith, Kevin A; Tarantal, Alice F; Rubin, Daniel L; Lyster, Peter

    2011-02-01

    The biomedical research community relies on a diverse set of resources, both within their own institutions and at other research centers. In addition, an increasing number of shared electronic resources have been developed. Without effective means to locate and query these resources, it is challenging, if not impossible, for investigators to be aware of the myriad resources available, or to effectively perform resource discovery when the need arises. In this paper, we describe the development and use of the Biomedical Resource Ontology (BRO) to enable semantic annotation and discovery of biomedical resources. We also describe the Resource Discovery System (RDS) which is a federated, inter-institutional pilot project that uses the BRO to facilitate resource discovery on the Internet. Through the RDS framework and its associated Biositemaps infrastructure, the BRO facilitates semantic search and discovery of biomedical resources, breaking down barriers and streamlining scientific research that will improve human health. Copyright © 2010 Elsevier Inc. All rights reserved.

  20. In vitro study on dental erosion provoked by various beverages using electron probe microanalysis.

    Science.gov (United States)

    Willershausen, B; Schulz-Dobrick, B

    2004-09-29

    Tooth erosion is often based on chemical processes, among others the use of soft drinks or diverse beverages. The aim of this in vitro study was to analyse the erosive potential of different acidic beverages. Over a time span of 6 hours, dental slices (n=6 slices per tooth) from fully retained wisdom teeth were incubated with different beverages (coca cola, ice tea with lemon, apple juice and white wine). The controls were incubated with a 0.9% sodium chloride solution under the same conditions (37 degrees C, humidified atmosphere of 5% CO2 and 95% air). The quantitative elementary analysis for calcium, phosphorus, oxygen and other trace elements in the dental slices in various depths ranging from 5 to 50 microm was carried out using an electron probe micro-analyser (Jeol JXA 8900RL). A beverage-induced loss of minerals, particularly of the 2 main components calcium and phosphorus, especially in the uppermost layers of the enamel down to a depth of 30 microm could be observed. In the depth of 10 microm, the following total mineral loss could be determined: white wine (16%), coca cola (14.5%), apple juice (6.5%) and ice tea with lemon (6.5%). A direct correlation between the loss of minerals and the pH value of the beverages was not observed, because of the buffering effect of the drinks. The conversion of the weight percentages from the chemical analysis of Ca and P to their atomic percentages showed that during erosion the 2 main components were not dissolved in significantly different percentages. In this study the erosive potential of the tested soft drinks and other beverages could be demonstrated. However, it must be considered that numerous modifying factors influence the enamel surface, so an extrapolation from the in vitro study to an in vivo situation can only be applied with caution.

  1. Electronic Recruitment at CERN

    CERN Multimedia

    2004-01-01

    The Human Resources Department switches to electronic recruitment. From now on whenever you are involved in a recruitment action you will receive an e-mail giving you access to a Web folder. Inside you will find a shortlist of applications drawn up by the Human Resources Department. This will allow you to consult the folder, at the same time as everyone else involved in the recruitment process, for the vacancy you are interested in. This new electronic recruitment system, known as e-RT, will be introduced in a presentation given at 10 a.m. on 11 February in the Main Auditorium. Implemented by AIS (Administrative Information Services) and the Human Resources Department, e-RT will cover vacancies open in all of CERN's recruitment programmes. The electronic application system was initially made available to technical students in July 2003. By December it was extended to summer students, fellows, associates and Local Staff. Geraldine Ballet from the Recruitment Service prefers e-RT to mountains of paper! The Hu...

  2. Plastics disassembly versus bulk recycling: engineering design for end-of-life electronics resource recovery.

    Science.gov (United States)

    Rios, Pedro; Stuart, Julie Ann; Grant, Ed

    2003-12-01

    Annual plastic flows through the business and consumer electronics manufacturing supply chain include nearly 3 billion lb of high-value engineering plastics derived from petroleum. The recovery of resource value from this stream presents critical challenges in areas of materials identification and recycling process design that demand new green engineering technologies applied together with life cycle assessment and ecological supply chain analysis to create viable plastics-to-plastics supply cycles. The sustainable recovery of potentially high-value engineering plastics streams requires that recyclers either avoid mixing plastic parts or purify later by separating smaller plastic pieces created in volume reduction (shredding) steps. Identification and separation constitute significant barriers in the plastics-to-plastics recycling value proposition. In the present work, we develop a model that accepts randomly arriving electronic products to study scenarios by which a recycler might identify and separate high-value engineering plastics as well as metals. Using discrete eventsimulation,we compare current mixed plastics recovery with spectrochemical plastic resin identification and subsequent sorting. Our results show that limited disassembly with whole-part identification can produce substantial yields in separated streams of recovered engineering thermoplastics. We find that disassembly with identification does not constitute a bottleneck, but rather, with relatively few workers, can be configured to pull the process and thus decrease maximum staging space requirements.

  3. X-ray microanalysis with microcalorimeters

    Energy Technology Data Exchange (ETDEWEB)

    Isaila, C. [Technische Universitaet Muenchen, Physik Department E15, James Franck Strasse, 85748 Garching (Germany)]. E-mail: cisaila@ph.tum.de; Feilitzsch, F. von [Technische Universitaet Muenchen, Physik Department E15, James Franck Strasse, 85748 Garching (Germany); Hoehne, J. [VeriCold Technologies GmbH, Bahnhofstrasse 21, 85737 Ismaning (Germany); Hollerith, C. [Technische Universitaet Muenchen, Physik Department E15, James Franck Strasse, 85748 Garching (Germany); Infineon Technologies AG, Failure Analysis FA5, Munich (Germany); Phelan, K. [VeriCold Technologies GmbH, Bahnhofstrasse 21, 85737 Ismaning (Germany); Simmnacher, B. [Infineon Technologies AG, Failure Analysis FA5, Munich (Germany); Weiland, R. [Infineon Technologies AG, Failure Analysis FA5, Munich (Germany); Wernicke, D. [Technische Universitaet Muenchen, Physik Department E15, James Franck Strasse, 85748 Garching (Germany); VeriCold Technologies GmbH, Bahnhofstrasse 21, 85737 Ismaning (Germany)

    2006-04-15

    The combination of high-energy-resolution spectrometers with high-spatial-resolution scanning electron microscopes provides a powerful tool for material analysis. X-ray spectrometers based on superconducting transition edge sensors combine the advantages of commonly used energy- and wavelength-dispersive spectrometers, i.e. a fast spectrum acquisition and a high-energy-resolution over a wide energy range. While the energies of the characteristic lines present in a spectrum contain the qualitative composition of the analyzed material, the corresponding mass fractions can be obtained from their intensities. In this work first quantitative measurements performed with the POLARIS spectrometer system are presented.

  4. Observations on thermally cycled 20% Cr/25% Ni/Nb stabilised stainless steel

    International Nuclear Information System (INIS)

    Lobb, R.C.

    1984-06-01

    A variety of optical and electron techniques, such as optical metallography, scanning electron microscopy and electron probe microanalysis, have been used to study the morphology and composition of oxides formed on 20 Cr/25 Ni/Nb stainless steel during oxidation at 850 0 C and subsequent thermal cycling in simulated reactor gas. (author)

  5. Merge of terminological resources

    DEFF Research Database (Denmark)

    Henriksen, Lina; Braasch, Anna

    2012-01-01

    In our globalized world, the amount of cross-national communication increases rapidly, which also calls for easy access to multi-lingual high quality terminological resources. Sharing of terminology resources is currently becoming common practice, and efficient strategies for integration...... – or merging – of terminology resources are strongly needed. This paper discusses prerequisites for successful merging with the focus on identification of candidate duplicates of a subject domain found in the resources to be merged, and it describes automatic merging strategies to be applied to such duplicates...... in electronic terminology resources. Further, some perspectives of manual, supplementary assessment methods supporting the automatic procedures are sketched. Our considerations are primarily based on experience gained in the IATE and EuroTermBank projects, as merging was a much discussed issue in both projects....

  6. Laser assisted modification and chemical metallization of electron-beam deposited ceria thin films

    International Nuclear Information System (INIS)

    Krumov, E.; Starbov, N.; Starbova, K.; Perea, A.; Solis, J.

    2009-01-01

    Excimer laser processing is applied for tailoring the surface morphology and phase composition of CeO 2 ceramic thin films. E-beam evaporation technique is used to deposit samples on stainless steel and silicate glass substrates. The films are then irradiated with ArF* excimer laser pulses under different exposure conditions. Scanning electron microscopy, optical spectrophotometry, X-ray diffractometry and EDS microanalysis are used to characterize the non-irradiated and laser-processed films. Upon UV laser exposure there is large increase of the surface roughness that is accompanied by photo-darkening and ceria reduction. It is shown that the laser induced changes in the CeO 2 films facilitate the deposition of metal nano-aggregates in a commercial copper electroless plating bath. The significance of laser modification as a novel approach for the production of CeO 2 based thin film catalysts is discussed.

  7. Laser assisted modification and chemical metallization of electron-beam deposited ceria thin films

    Energy Technology Data Exchange (ETDEWEB)

    Krumov, E., E-mail: emodk@clf.bas.bg [Central Laboratory of Photoprocesses ' Acad. Jordan Malinowski' , Bulgarian Academy of Sciences, Acad. Georgy Bonchev Str., bl. 109, 1113 Sofia (Bulgaria); Starbov, N.; Starbova, K. [Central Laboratory of Photoprocesses ' Acad. Jordan Malinowski' , Bulgarian Academy of Sciences, Acad. Georgy Bonchev Str., bl. 109, 1113 Sofia (Bulgaria); Perea, A.; Solis, J. [Instituto de Optica ' Daza de Valdes' , CSIC, 28006 Madrid (Spain)

    2009-11-15

    Excimer laser processing is applied for tailoring the surface morphology and phase composition of CeO{sub 2} ceramic thin films. E-beam evaporation technique is used to deposit samples on stainless steel and silicate glass substrates. The films are then irradiated with ArF* excimer laser pulses under different exposure conditions. Scanning electron microscopy, optical spectrophotometry, X-ray diffractometry and EDS microanalysis are used to characterize the non-irradiated and laser-processed films. Upon UV laser exposure there is large increase of the surface roughness that is accompanied by photo-darkening and ceria reduction. It is shown that the laser induced changes in the CeO{sub 2} films facilitate the deposition of metal nano-aggregates in a commercial copper electroless plating bath. The significance of laser modification as a novel approach for the production of CeO{sub 2} based thin film catalysts is discussed.

  8. Complete electronics self-teaching guide with projects

    CERN Document Server

    Boysen, Earl

    2012-01-01

    An all-in-one resource on everything electronics-related! For almost 30 years, this book has been a classic text for electronics enthusiasts. Now completely updated for today's technology, this latest version combines concepts, self-tests, and hands-on projects to offer you a completely repackaged and revised resource. This unique self-teaching guide features easy-to-understand explanations that are presented in a user-friendly format to help you learn the essentials you need to work with electronic circuits. All you need is a general understanding of electronics concepts such as Oh

  9. X-ray spectrum determination of elements with low atomic number with use of electron microscope

    International Nuclear Information System (INIS)

    Smirnov, V.N.

    1982-01-01

    Separate assemblies of a commercial analytical electron microscope-microanalyzer EMMA-2 have been modified to study objects, containing elements with the atomic number Z=5-9, in particular: 1) the range of changing the accelerating voltages is expanded to be in the range of 25 down to 10 kV with 5 kV interval. 2) image intensifier using microchannel plate MKP-40-19 is applied; 3) for elements of carbon, oxygen, boron, nitrogen type a unit with flow-type proportional counter is used. The sensitivity of carbon- and oxygen determination in carbides and oxides is 0.15-0.3% at the measurement time of 100 s. Results of microanalysis of the particles of B 2 O 3 , Al 2 O 3 , SiO 2 , Fe 2 O 3 , Fe 3 C, WC for the contents of oxygen and carbon are presented

  10. Effect of fluoride and cobalt on forming enamel: scanning electron microscope and X-ray microanalysis study

    International Nuclear Information System (INIS)

    Ashrafi, S.H.; Eisenmann, D.R.; Zaki, A.E.; Liss, R.

    1988-01-01

    The forming surfaces of enamel of rat incisors were examined by scanning electron microscope one hour after injection of either 5 mg/100 g body weight of sodium fluoride or 12 mg/100 g body weight of cobalt chloride. The cell debris from the surfaces of the separated incisors was either gently wiped off with soft facial tissues or chemically removed by treating with NaOH, NaOCl or trypsin. Best results to remove cell debris were obtained from 0.25% trypsin treatment. SEM studies revealed that the surface of the normal secretory enamel was characteristic in appearance with well-developed smooth prism outlines. In fluoride specimens the prism outlines were feathery in appearance, laced with protruding spine-shaped clusters of mineral crystals. In the case of cobalt treatment, prism outlines were less uniform and in some areas they were incomplete. The calcium concentration of surface enamel was significantly lower in the cobalt-treated specimens than those from control and fluoride-treated animals. The Ca:Mg ratio was also lower in cobalt-treated specimens as compared to control and fluoride-treated ones

  11. Oscillator clustering in a resource distribution chain

    DEFF Research Database (Denmark)

    Postnov, D.; Sosnovtseva, Olga; Mosekilde, Erik

    2005-01-01

    separate the inherent dynamics of the individual oscillator from the properties of the coupling network. Illustrated by examples from microbiological population dynamics, renal physiology, and electronic oscillator theory, we show how competition for primary resources in a resource distribution chain leads...

  12. High-temperature stability of yttria-stabilized zirconia thermal barrier ...

    Indian Academy of Sciences (India)

    The coatings before and after IR heating were investigated by scanning electron microscopy, X-ray diffraction, electron probe microanalysis, microhardness and residual stress measurements in order to understand the effect of thermal shock on the properties of the TBC. On account of these high-temperature properties, ...

  13. Contribution of a new generation field-emission scanning electron microscope in the understanding of a 2099 Al-Li alloy.

    Science.gov (United States)

    Brodusch, Nicolas; Trudeau, Michel; Michaud, Pierre; Rodrigue, Lisa; Boselli, Julien; Gauvin, Raynald

    2012-12-01

    Aluminum-lithium alloys are widespread in the aerospace industry. The new 2099 and 2199 alloys provide improved properties, but their microstructure and texture are not well known. This article describes how state-of-the-art field-emission scanning electron microscopy (FE-SEM) can contribute to the characterization of the 2099 aluminum-lithium alloy and metallic alloys in general. Investigations were carried out on bulk and thinned samples. Backscattered electron imaging at 3 kV and scanning transmission electron microscope imaging at 30 kV along with highly efficient microanalysis permitted correlation of experimental and expected structures. Although our results confirm previous studies, this work points out possible substitutions of Mg and Zn with Li, Al, and Cu in the T1 precipitates. Zinc and magnesium are also present in "rice grain"-shaped precipitates at the grain boundaries. The versatility of the FE-SEM is highlighted as it provides information in the macro- and microscales with relevant details. Its ability to probe the distribution of precipitates from nano- to microsizes throughout the matrix makes FE-SEM an essential technique for the characterization of metallic alloys.

  14. Power Electronics

    DEFF Research Database (Denmark)

    Iov, Florin; Ciobotaru, Mihai; Blaabjerg, Frede

    2008-01-01

    is to change the electrical power production sources from the conventional, fossil (and short term) based energy sources to renewable energy resources. The other is to use high efficient power electronics in power generation, power transmission/distribution and end-user application. This paper discuss the most...... emerging renewable energy sources, wind energy, which by means of power electronics are changing from being a minor energy source to be acting as an important power source in the energy system. Power electronics is the enabling technology and the presentation will cover the development in wind turbine...... technology from kW to MW, discuss which power electronic solutions are most feasible and used today....

  15. X-ray microanalysis with transition edge sensors. The future of material analysis with scanning electron microscopes

    Energy Technology Data Exchange (ETDEWEB)

    Hollerith, C.

    2006-07-05

    In current experiments and technical applications the demand for new and advanced concepts for the detection of radiation and particle is increasing. Low temperature detectors such as Transition Edge Sensors (TES) have been developed as ultrahigh-resolution radiation and particle detectors offering advantages in manifold applications. They were designed primarily for astrophysical experiments such as the dark matter search. In material analysis they have been introduced to revolutionize mass spectroscopy of biological molecules and Energy Dispersive X-ray Spectroscopy (EDS). EDS is the determination of the elemental constitution of samples in scanning electron microscopes (SEMs) with characteristic X-ray radiation excited by the electron beam. The use of TES detectors improves the EDS analysis of small volumes such as particles or thin layers. This is especially important for the semiconductor industry because of the continual shrinking of device size. Current structure sizes of 65 nm are already demanding new approaches in analytic methodology. In this thesis the introduction and improvement of a fully automated TES detector system in the industrial environment of a semiconductor failure analysis lab is described. This system, marketed under the trade name of 'Polaris' by the manufacturer, is based on a mechanical pulse tube cooler in combination with an adiabatic demagnetization refrigerator (ADR) for cooling the TES detector to its operating temperature. Several large improvements had to be made to the system during the total system integration. The energy resolution could be improved significantly thus enabling a better peak separation and the measurement of chemical shifts. Due to the small area of TES detectors compared with conventional EDS detectors the efficiency of the system proved to be too low for everyday use. A polycapillary X-ray lens was added to the system in order to solve this problem. The application of the lens, however, brought its

  16. Electronic conferencing for continuing medical education: a resource survey.

    Science.gov (United States)

    Sternberg, R J

    1986-10-01

    The use of electronic technologies to link participants for education conferences is an option for providers of Continuing Medical Education. In order to profile the kinds of electronic networks currently offering audio- or videoteleconferences for physician audiences, a survey was done during late 1985. The information collected included range of services, fees, and geographic areas served. The results show a broad diversity of providers providing both interactive and didactic programming to both physicians and other health care professionals.

  17. Possibilities and prospects of investigation of irradiated structural and fuel materials using scanning electron microscope PHILLIPS XL 30 ESEM-TMP installed in the hot cell

    International Nuclear Information System (INIS)

    Golovanov, V. N.; Novoselov, A.E.; Kuzmin, S.V.; Yakovlev, V. V.

    2005-01-01

    Scanning electron microscope Philips XL 30 ESEM - TMP with X-ray microanalysis system INCA has been installed at SSC RF RIAR. The microscope is placed in the hot cell. Monitoring and control system is installed in the operator's room. Irradiated specimens are supplied to the hot cell through the transport terminal and installed into the microscope by manipulators. Direct contact of the personnel with radioactive materials is impossible. In addition it is developed the system of remote placement of the irradiated specimens into the specimen chamber of microscope. The system includes a stage with three seats, holders for different types of specimens and equipment for their remote loading in the holders. (Author)

  18. Rediscovering Ducos du Hauron's Color Photography through a Review of His Three-Color Printing Processes and Synchrotron Microanalysis of His Prints.

    Science.gov (United States)

    Cotte, Marine; Fabris, Tiphaine; Langlois, Juliette; Bellot-Gurlet, Ludovic; Ploye, Françoise; Coural, Natalie; Boust, Clotilde; Gandolfo, Jean-Paul; Galifot, Thomas; Susini, Jean

    2018-06-18

    Louis Ducos du Huron (1837-1920) dedicated his entire life to the elaboration of physical-chemical processes for color photography. This study aimed at highlighting his unique contribution to three-color printing through 1) an in-depth review of the many protocols he published and 2) the synchrotron-based IR and X-ray microanalysis of fragments sampled in three artworks. Ducos du Hauron's method relied on the preparation and assembly of three monochromes (red, blue, yellow). This study brings to light complex multistep recipes based on photochemistry (carbon print), organic, and inorganic chemistry. The various ingredients involved (e.g., pigments, dichromate gelatin, collodion, resin) were identified and localized through their spectroscopic signature, confirming the relevance of synchrotron spectromicroscopy for the characterization of historical photographs. The impressive correlation between texts and chemical analyses calls for a wider application to the history of photography. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Semi-quantitative X-ray microanalysis of bronchoalveolar lavage samples from silica-exposed and nonexposed subjects

    International Nuclear Information System (INIS)

    Lusuardi, M.; Capelli, A.; Donner, C.F.; Capelli, O.; Velluti, G.

    1992-01-01

    To evaluate the possibility of quantifying alveolar dust burden in conditions of exposure to silica, four groups of subjects were submitted to bronchoalveolar lavage (BAL): 10 healthy control subjects and 39 patients affected by diffuse interstitial lung disease (DILD) never exposed to dust, 23 silicotic patients and 12 chronic bronchitis patients with a history of occupational exposure to silica dust. Five to ten million BAL recovered cells were analysed with an energy-dispersive X-ray microanalysis (EDXA) system to determine the silicon content, expressed in a semi-quantitative way as silicon to sulphur (Si/S) ratio. The results were independent of smoking habit. The Si/S median values (interquartile range in brackets) for the four groups were 0.53 (0.5-0.65), 0.60 (0.41-0.8), 1.23 (1.06-1.39); 1.31 (1.11-1.97), respectively. Silicotics and simply exposed individuals did not show a significant discrepancy, but they were both significantly different in comparison with normal and DILD patients without history of exposure (p<0.001). 14.3% false negative cases were found, and 4.1% false positive cases (none among normal subjects). We did not se any significant relationships between the amount of silicon and the duration of exposure or the degree of chest X-ray involvement. A study of cytocentrifuge slides from the same subjects by polarizing light microscopy revealed a lower sensitivity (34% false negative cases). (au)

  20. Utilization of bio-resources by low energy electron beam

    International Nuclear Information System (INIS)

    Kume, Tamikazu

    2003-01-01

    Utilization of bio-resources by radiation has been investigated for recycling the natural resources and reducing the environmental pollution. Polysaccharides such as chitosan and sodium alginate were easily degraded by irradiation and induced various kinds of biological activities, i.g. anti-microbial activity, promotion of plant growth, suppression of heavy metal stress, phytoalexins induction. Radiation degraded chitosan was effective to enhance the growth of plants in tissue culture. It was demonstrated that the liquid sample irradiation system using low energy EB was effective for the preparation of degraded polysaccharides. Methylcellulose (MC) can be crosslinked under certain radiation condition as same as carboxymethylcellulose (CMC) and produced the biodegradable hydrogel for medical and agricultural use. Treatment of soybean seeds by low energy EB enhanced the growth and the number of rhizobia on the root. (author)

  1. In Depth Analyses of LEDs by a Combination of X-ray Computed Tomography (CT) and Light Microscopy (LM) Correlated with Scanning Electron Microscopy (SEM).

    Science.gov (United States)

    Meyer, Jörg; Thomas, Christian; Tappe, Frank; Ogbazghi, Tekie

    2016-06-16

    In failure analysis, device characterization and reverse engineering of light emitting diodes (LEDs), and similar electronic components of micro-characterization, plays an important role. Commonly, different techniques like X-ray computed tomography (CT), light microscopy (LM) and scanning electron microscopy (SEM) are used separately. Similarly, the results have to be treated for each technique independently. Here a comprehensive study is shown which demonstrates the potentials leveraged by linking CT, LM and SEM. In depth characterization is performed on a white emitting LED, which can be operated throughout all characterization steps. Major advantages are: planned preparation of defined cross sections, correlation of optical properties to structural and compositional information, as well as reliable identification of different functional regions. This results from the breadth of information available from identical regions of interest (ROIs): polarization contrast, bright and dark-field LM images, as well as optical images of the LED cross section in operation. This is supplemented by SEM imaging techniques and micro-analysis using energy dispersive X-ray spectroscopy.

  2. Structure and properties of combined coatings on C (graphite)/Al/Al2O3 base after Ti ion implantation with subsequent electron beam irradiation

    International Nuclear Information System (INIS)

    Pogrebnjak, A.D.; Pogrebnjak, N.A.; Gritsenko, B.P.; Kylyshkanov, M.K.; Ruzimov, Sh.M.

    2004-01-01

    Full text: The presented report deals with new results on deposition of combined coatings using Al metallization (by a plasma jet) and micro-arc (discharge) Al oxidation. After this, the coating was implanted by Ti ions with 5·10 I7 cm -2 dose (60 and 90 kV and about 200 μs duration). One series of samples with such coatings was irradiated using the accelerator Y-112 by an electron beam in melting regime (two regimes). Analysis of the structure and element composition was performed using SIMS, RBS, SEM with micro-analysis (WDS), XRD as well as measurements of microhardness, wear and adhesion. It had been demonstrated that the coating was able to sustain very high temperatures and oxidation medium. However, after electron beam irradiation temperature resistance decreased because the oxide coating was melted almost to the graphite surface. The work was funded by the Project of NANU 'Nanosystems, nanomaterials and nanotechnology'

  3. Adaptation of mathematical educational content in e-learning resources

    Directory of Open Access Journals (Sweden)

    Yuliya V. Vainshtein

    2017-01-01

    Full Text Available Modern trends in the world electronic educational system development determine the necessity of adaptive learning intellectual environments and resources’ development and implementation. An upcoming trend in improvement the quality of studying mathematical disciplines is the development and application of adaptive electronic educational resources. However, the development and application experience of adaptive technologies in higher education is currently extremely limited and does not imply the usage flexibility. Adaptive educational resources in the electronic environment are electronic educational resources that provide the student with a personal educational space, filled with educational content that “adapts” to the individual characteristics of the students and provides them with the necessary information.This article focuses on the mathematical educational content adaptation algorithms development and their implementation in the e-learning system. The peculiarity of the proposed algorithms is the possibility of their application and distribution for adaptive e-learning resources construction. The novelty of the proposed approach is the three-step content organization of the adaptive algorithms for the educational content: “introductory adaptation of content”, “the current adaptation of content”, “estimative and a corrective adaptation”. For each stage of the proposed system, mathematical algorithms for educational content adaptation in adaptive e-learning resources are presented.Due to the high level of abstraction and complexity perception of mathematical disciplines, educational content is represented in the various editions of presentation that correspond to the levels of assimilation of the course material. Adaptation consists in the selection of the optimal edition of the material that best matches the individual characteristics of the student. The introduction of a three-step content organization of the adaptive

  4. Microanalysis of metals in barbs of a snow petrel (Pagodroma Nivea) from the Antarctica using synchrotron radiation X-ray fluorescence.

    Science.gov (United States)

    Xie, Zhouqing; Zhang, Pengfei; Sun, Liguang; Xu, Siqi; Huang, Yuying; He, Wei

    2008-03-01

    For the first time synchrotron radiation X-ray fluorescence (SR-XRF) microanalysis was performed throughout the total length of 4 single barbs from the primaries and secondaries of a snow petrel (Pagodroma Nivea) collected in the Antarctica. Thirteen elements (S, Mg, K, Ca, Fe, Ni, Cu, Zn, Se, Sr, Ba, Hg and Pb) were detected somewhere in the barbs. Variations in levels of these elements within and among the barbs were obvious, indicating nonuniform microscale distributions. Factors influencing the fluctuations of the levels of the elements were investigated using a multivariate statistical analysis method. Five factors (F1 being associated with high loadings of Ca, Sr, and Ni, F2 with high loadings of Fe and Ba, F3 with high loadings of Se and Hg, F4 with high loadings of Ca and K, and F5 with high loadings of Zn and Pb) were found to explain about 80% of the total variance. Results from the factor analysis suggested external contamination of Fe, Ba, Pb, Zn and Hg on the feathers of the snow petrel.

  5. Microanalysis of metals in barbs of a snow petrel (Pagodroma Nivea) from the Antarctica using synchrotron radiation X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Xie Zhouqing [Institute of Polar Environment, School of Earth and Space Sciences, University of Science and Technology of China, Hefei, Anhui 230026 (China)], E-mail: zqxie@ustc.edu.cn; Zhang Pengfei [Department of Earth and Atmospheric Sciences, City College of New York, New York, NY 10031 (United States); Sun Liguang; Xu Siqi [Institute of Polar Environment, School of Earth and Space Sciences, University of Science and Technology of China, Hefei, Anhui 230026 (China); Huang Yuying; He Wei [Institute of High Energy Physics, Chinese Academy of Sciences, 100039 Beijing (China)

    2008-03-15

    For the first time synchrotron radiation X-ray fluorescence (SR-XRF) microanalysis was performed throughout the total length of 4 single barbs from the primaries and secondaries of a snow petrel (Pagodroma Nivea) collected in the Antarctica. Thirteen elements (S, Mg, K, Ca, Fe, Ni, Cu, Zn, Se, Sr, Ba, Hg and Pb) were detected somewhere in the barbs. Variations in levels of these elements within and among the barbs were obvious, indicating nonuniform microscale distributions. Factors influencing the fluctuations of the levels of the elements were investigated using a multivariate statistical analysis method. Five factors (F1 being associated with high loadings of Ca, Sr, and Ni, F2 with high loadings of Fe and Ba, F3 with high loadings of Se and Hg, F4 with high loadings of Ca and K, and F5 with high loadings of Zn and Pb) were found to explain about 80% of the total variance. Results from the factor analysis suggested external contamination of Fe, Ba, Pb, Zn and Hg on the feathers of the snow petrel.

  6. Microanalysis of metals in barbs of a snow petrel (Pagodroma Nivea) from the Antarctica using synchrotron radiation X-ray fluorescence

    International Nuclear Information System (INIS)

    Xie Zhouqing; Zhang Pengfei; Sun Liguang; Xu Siqi; Huang Yuying; He Wei

    2008-01-01

    For the first time synchrotron radiation X-ray fluorescence (SR-XRF) microanalysis was performed throughout the total length of 4 single barbs from the primaries and secondaries of a snow petrel (Pagodroma Nivea) collected in the Antarctica. Thirteen elements (S, Mg, K, Ca, Fe, Ni, Cu, Zn, Se, Sr, Ba, Hg and Pb) were detected somewhere in the barbs. Variations in levels of these elements within and among the barbs were obvious, indicating nonuniform microscale distributions. Factors influencing the fluctuations of the levels of the elements were investigated using a multivariate statistical analysis method. Five factors (F1 being associated with high loadings of Ca, Sr, and Ni, F2 with high loadings of Fe and Ba, F3 with high loadings of Se and Hg, F4 with high loadings of Ca and K, and F5 with high loadings of Zn and Pb) were found to explain about 80% of the total variance. Results from the factor analysis suggested external contamination of Fe, Ba, Pb, Zn and Hg on the feathers of the snow petrel

  7. Internet and Electronic Information Management

    Science.gov (United States)

    2004-12-01

    centers to form consortia and share electronic information sources. Although traditional resource sharing arrangements encouraged competition rather...outside world, through public relations and through marketing information products or services, to its own competitive advantage (Davenport 1997: 193-217... electronic information sources are a challenge for electronic information managers. Libraries and information centers are no longer “the only game in town

  8. Energy and resource utilization of deinking sludge pyrolysis

    International Nuclear Information System (INIS)

    Lou, Rui; Wu, Shubin; Lv, Gaojin; Yang, Qing

    2012-01-01

    The thermochemical conversion technique was applied in deinking sludge from the pulp and papermaking industrial to indagate the utilization of sludge biomass to energy, and the pyrolysis characteristics and pyrolytic products of deinking sludge were studied with thermogravimetric analysis (TGA) and pyrolysis coupled with gas chromatograph–mass spectrometer (Py-GC/MS). The static tubular furnace as an applied industrial research was used to study deinking sludge pyrolysis. The solid, gas and liquid of products was characterized by electron probe microanalysis (EPMA), gas chromatograph (GC) and gas chromatograph–mass (GC/MS), respectively. The results revealed that the weight-loss process of deinking sludge was a non-isothermal reaction and composed of four stages, i.e. dewater stage, volatile releasing stage, carbon burnout stage and some calcium carbonate decomposition. Pyrolytic products from deinking sludge in the static tubular furnace were comprised of the gaseous (29.78%), condensed liquid (bio-oil, 24.41%) and solid residues (45.81%). The volatiles from deinking sludge pyrolyzing were almost aromatic hydrocarbons, i.e. styrene, toluene and benzene and few acids and the solid was calcium carbonate (CaCO 3 ) that can be reused as paper filler. Deinking sludge was converted into high-grade fuel and chemicals by means of thermochemical conversion techniques, hence, pyrolysis of paper deinking sludge had a promising development on the comprehensive utilization.

  9. Microanalysis of individual particles from urban aerosols

    International Nuclear Information System (INIS)

    Lizarragga, M.; Alves, R.N.; Cunha, K.D. da; D'Oliveira, D.

    1995-01-01

    Air samples were collected using a cascade impactor, close to Auto Estrada Lagoa-Barra, Rio de Janeiro. An electronic microscope was used to determine the elemental composition of each particle. About 500 particles were analyzed. Air samples were collected using a six stage cascade impactor, with a flow rate of 12 l/min. The collected particles in each stage of the cascade impactor were analyzed using an electron beam of 50 keV. The elemental mass composition of each stage of the cascade impactor was determined. The results indicate that there was no significant difference among the elemental composition of each one of six stages. Most of the collected particles were Na Cl crystal. Amorphi forms were also observed containing Al, S, Ti, Ca, Fe, Cu, Si and others. After the microscopy analysis, the samples were analyzed by PIXE method to determine the elemental mass concentration in each stage of the cascade impactor. The results from PIXE and microscopy analysis are shown in this paper. (author). 2 refs, 3 figs, 2 tabs

  10. Electronic Information Access and Utilization by Makerere University Students in Uganda

    Directory of Open Access Journals (Sweden)

    Elisam Magara

    2008-09-01

    Full Text Available Objectives – The objectives of this study were to establish the level of computer utilization skills of Makerere University (Uganda Library and Information Science (LIS students; to determine the use of electronic information resources by LIS students; to determine the attitudes of LIS students towards electronic information resources; and to establish the problems faced by LIS students in accessing electronic information resources.Methods – A questionnaire survey was used for data collection.Results – The majority of Library and Information Science students at Makerere University depend on university computers for their work, and very few of them access the library’s e-resources. The few who access e-resources are self-taught. The majority of students surveyed were unaware of Emerald and EBSCO databases relevant to Library and Information Science students, and they found accessing eresources time-consuming. Conclusion – The study concluded that a concerted effort is needed by both LIS lecturers and university librarians in promoting use of the library’s electronic resources.

  11. Dynamic models for distributed generation resources

    Energy Technology Data Exchange (ETDEWEB)

    Morched, A.S. [BPR Energie, Sherbrooke, PQ (Canada)

    2010-07-01

    Distributed resources can impact the performance of host power systems during both normal and abnormal system conditions. This PowerPoint presentation discussed the use of dynamic models for identifying potential interaction problems between interconnected systems. The models were designed to simulate steady state behaviour as well as transient responses to system disturbances. The distributed generators included directly coupled and electronically coupled generators. The directly coupled generator was driven by wind turbines. Simplified models of grid-side inverters, electronically coupled wind generators and doubly-fed induction generators (DFIGs) were presented. The responses of DFIGs to wind variations were evaluated. Synchronous machine and electronically coupled generator responses were compared. The system model components included load models, generators, protection systems, and system equivalents. Frequency responses to islanding events were reviewed. The study demonstrated that accurate simulations are needed to predict the impact of distributed generation resources on the performance of host systems. Advances in distributed generation technology have outpaced the development of models needed for integration studies. tabs., figs.

  12. X-ray micro-analysis of the mineralization patterns in developing enamel in hamster tooth germs exposed to fluoride in vitro during the secretory phase of amelogenesis

    International Nuclear Information System (INIS)

    Lyaruu, D.M.; Blijleven, N.; Hoeben-Schornagel, K.; Bronckers, A.L.; Woeltgens, J.H.

    1989-01-01

    The developing enamel from three-day-old hamster first maxillary (M1) molar tooth germs exposed to fluoride (F-) in vitro was analyzed for its mineral content by means of the energy-dispersive x-ray microanalysis technique. The aim of this study was to obtain semi-quantitative data on the F(-)-induced hypermineralization patterns in the enamel and to confirm that the increase in electron density observed in micrographs of F(-)-treated enamel is indeed due to an increase in mineral content in the fluorotic enamel. The tooth germs were explanted during the early stages of secretory amelogenesis and initially cultured for 24 hr in the presence of 10 ppm F- in the culture medium. The germs were then cultured for another 24 hr without F-. In order to compare the ultrastructural results directly with the microprobe data, we used the same specimens for both investigations. The net calcium counts (measurement minus background counts) in the analyses were used as a measure of the mineral content in the enamel. The aprismatic pre-exposure enamel, deposited in vivo before the onset of culture, was the most hypermineralized region in the fluorotic enamel, i.e., it contained the highest amount of calcium measured. The degree of the F(-)-induced hypermineralization gradually decreased (but was not abolished) in the more mature regions of the enamel. The unmineralized enamel matrix secreted during the initial F- treatment in vitro mineralized during the subsequent culture without F-. The calcium content in this enamel layer was in the same order of magnitude as that recorded for the newly deposited enamel in control tooth germs cultured without F-

  13. Availability of Electronic Resources for Service Provision in ...

    African Journals Online (AJOL)

    The study also revealed that majority of the University libraries have adequate basic infrastructure for effective electronic information services. ... acquired by the library are put into maximal use by the library clientele, thereby ensuring the achievement of the library's objective which is satisfying the users, information needs.

  14. Solvothermal synthesis and characterization of acicular α-Fe2O3 ...

    Indian Academy of Sciences (India)

    Administrator

    dispersive X-ray microanalysis (EDAX), X-ray photoelectron spectroscopy (XPS), scanning electron micro- ... acicular shaped nanoparticles are seen in TEM images with an aspect ratio ~ 12; typically 8–12 nm wide and .... no impurity signal.

  15. Emotional Intelligence Research within Human Resource Development Scholarship

    Science.gov (United States)

    Farnia, Forouzan; Nafukho, Fredrick Muyia

    2016-01-01

    Purpose: The purpose of this study is to review and synthesize pertinent emotional intelligence (EI) research within the human resource development (HRD) scholarship. Design/methodology/approach: An integrative review of literature was conducted and multiple electronic databases were searched to find the relevant resources. Using the content…

  16. Ion distribution measured by electron probe X-ray microanalysis in ...

    Indian Academy of Sciences (India)

    2012-08-13

    Aug 13, 2012 ... in plant organs or cells in spite of their abundance in soil or the growth medium ... organs in order to create a water potential gradient for inward ... essential nutrients while excluding toxic ions (Davenport 2007). In order to ...

  17. Study the microstructure of three and four component phases in Al-Ni-Fe-La alloys

    KAUST Repository

    Kolobylina, Natalia; Vasiliev, Alexander; Lopatin, Sergei; Presniakov, Mikhail; Bakhteeva, Natalia; Ivanova, Anna; Todorova, Elena

    2016-01-01

    in air were studied by scanning/transmission electron microscopy (STEM), energy dispersive X-ray (EDX) microanalysis and X-ray diffraction (XRD). The microstructural analyses were performed in a aberration corrected TITAN 80-300 TEM/STEM (FEI, USA

  18. Composition of nasal airway surface liquid in cystic fibrosis and other airway diseases determined by X-ray microanalysis.

    Science.gov (United States)

    Vanthanouvong, V; Kozlova, I; Johannesson, M; Nääs, E; Nordvall, S L; Dragomir, A; Roomans, G M

    2006-04-01

    The ionic composition of the airway surface liquid (ASL) in healthy individuals and in patients with cystic fibrosis (CF) has been debated. Ion transport properties of the upper airway epithelium are similar to those of the lower airways and it is easier to collect nasal ASL from the nose. ASL was collected with ion exchange beads, and the elemental composition of nasal fluid was determined by X-ray microanalysis in healthy subjects, CF patients, CF heterozygotes, patients with rhinitis, and with primary ciliary dyskinesia (PCD). In healthy subjects, the ionic concentrations were approximately isotonic. In CF patients, CF heterozygotes, rhinitis, and PCD patients, [Na] and [Cl] were significantly higher compared when compared with those in controls. [K] was significantly higher in CF and PCD patients compared with that in controls. Severely affected CF patients had higher ionic concentrations in their nasal ASL than in patients with mild or moderate symptoms. Female CF patients had higher levels of Na, Cl, and K than male patients. As higher salt concentrations in the ASL are also found in other patients with airway diseases involving chronic inflammation, it appears likely that inflammation-induced epithelial damage is important in determining the ionic composition of the ASL. Copyright (c) 2006 Wiley-Liss, Inc.

  19. To get or not to get: the KAUST library e-resources acquisition experience

    KAUST Repository

    Ramli, Rindra M.

    2014-06-01

    In the challenging times of budget cuts and reviews, libraries are faced with issues, among others, such as justifying acquisition, negotiating deals and reviewing current subscriptions (pertaining to electronic resources). With the rapid increase in growth of electronic resources, libraries have to continuously assess their acquisition models and policies to constantly ensure that they are balancing their budget and users’ needs as well. This paper highlights the role played by Technical and IT department of King Abdullah University of Science and Technology (KAUST) library (Saudi Arabia) in acquiring the electronic resources (electronic books, electronic journals, databases, image and reference) for the community. It will describe the processes during the early days when KAUST library was inaugurated; how electronic resources were acquired and what went through during those days. The paper will elaborate further how the acquisition model has evolved and the various important roles played by the library staff in ensuring that acquisitions/subscriptions are justified, within the budget and provides ROI for the library. King Abdullah University is a graduate research university which opened in September 2009 with its first cohort of 800 graduate students (25% female) taught by 100 faculties. The focus of study and research in the university are: Mathematics and Computer Science, Physical Sciences and Life Sciences. The university library started with 10 staff. The library has a “state-of-the-art learning and information resource center supporting graduate education and advanced scientific research” (KAUST, 2010).

  20. Thermal and electron stimulated luminescence of natural bones, commercial hydroxyapatite and collagen.

    Science.gov (United States)

    Roman-Lopez, J; Correcher, V; Garcia-Guinea, J; Rivera, T; Lozano, I B

    2014-01-01

    The luminescence (cathodoluminescence and thermoluminescence) properties of natural bones (Siberian mammoth and adult elephant), commercial hydroxyapatite and collagen were analyzed. Chemical analyses of the natural bones were determined using by Electron Probe Micro-Analysis (EMPA). Structural, molecular and thermal characteristics were determined by X-ray Diffraction (XRD), Raman spectroscopy and Differential Thermal and Thermogravimetric analysis (DTA-TG). Cathodoluminescence (CL) spectra of natural bones and collagen showed similar intense broad bands at 440 and 490 nm related to luminescence of the tetrahedral anion [Formula: see text] or structural defects. A weaker luminescence exhibited at 310 nm could be attributed to small amount of rare earth elements (REEs). Four luminescent bands at 378, 424, 468 and 576 nm were observed in the commercial hydroxyapatite (HAP). Both natural bones and collagen samples exhibited natural thermoluminescence (NTL) with well-defined glow curves whereas that the induced thermoluminescence (ITL) only appears in the samples of commercial hydroxyapatite and collagen. Additional explanations for the TL anomalous fading of apatite, as a crucial difficulty performing dosimetry and dating, are also considered. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Is scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) quantitative?

    Science.gov (United States)

    Newbury, Dale E; Ritchie, Nicholas W M

    2013-01-01

    Scanning electron microscopy/energy dispersive X-ray spectrometry (SEM/EDS) is a widely applied elemental microanalysis method capable of identifying and quantifying all elements in the periodic table except H, He, and Li. By following the "k-ratio" (unknown/standard) measurement protocol development for electron-excited wavelength dispersive spectrometry (WDS), SEM/EDS can achieve accuracy and precision equivalent to WDS and at substantially lower electron dose, even when severe X-ray peak overlaps occur, provided sufficient counts are recorded. Achieving this level of performance is now much more practical with the advent of the high-throughput silicon drift detector energy dispersive X-ray spectrometer (SDD-EDS). However, three measurement issues continue to diminish the impact of SEM/EDS: (1) In the qualitative analysis (i.e., element identification) that must precede quantitative analysis, at least some current and many legacy software systems are vulnerable to occasional misidentification of major constituent peaks, with the frequency of misidentifications rising significantly for minor and trace constituents. (2) The use of standardless analysis, which is subject to much broader systematic errors, leads to quantitative results that, while useful, do not have sufficient accuracy to solve critical problems, e.g. determining the formula of a compound. (3) EDS spectrometers have such a large volume of acceptance that apparently credible spectra can be obtained from specimens with complex topography that introduce uncontrolled geometric factors that modify X-ray generation and propagation, resulting in very large systematic errors, often a factor of ten or more. © Wiley Periodicals, Inc.

  2. Crystal structure of owyheeite, Ag1.5Pb4.43Sb6.07S14

    DEFF Research Database (Denmark)

    Laufek, Frantisek; Pazout, Richard; Makovicky, Emil

    2007-01-01

    to form lone electron pair micelles. Electron probe microanalysis gives (mean of 10 point analyses in wt. %): Ag 6.51(12), Cu 0.18(2), Pb 45.03(24), Sb 28.69(33), S 19.66(19), Total 100.08. Owyheeite belongs to a broad family of rod-based sulphosalt structures with the chess-board arrangement of the rods....

  3. Utilisation of Online Resources among Undergraduates in Nigerian ...

    African Journals Online (AJOL)

    Electronic book (e-book) was mostly utilized as against Ejournals and E-thesis, while mobile phones and cybercafés remain the channels used in accessing online resources. it was discovered that incessant power supply, slow Internet connectivity and lack of time to access the information resources are constraints to ...

  4. Automotive electronics design fundamentals

    CERN Document Server

    Zaman, Najamuz

    2015-01-01

    This book explains the topology behind automotive electronics architectures and examines how they can be profoundly augmented with embedded controllers. These controllers serve as the core building blocks of today’s vehicle electronics. Rather than simply teaching electrical basics, this unique resource focuses on the fundamental concepts of vehicle electronics architecture, and details the wide variety of Electronic Control Modules (ECMs) that enable the increasingly sophisticated "bells & whistles" of modern designs.  A must-have for automotive design engineers, technicians working in automotive electronics repair centers and students taking automotive electronics courses, this guide bridges the gap between academic instruction and industry practice with clear, concise advice on how to design and optimize automotive electronics with embedded controllers.

  5. Gaseous Electronics Tables, Atoms, and Molecules

    CERN Document Server

    Raju, Gorur Govinda

    2011-01-01

    With the constant emergence of new research and application possibilities, gaseous electronics is more important than ever in disciplines including engineering (electrical, power, mechanical, electronics, and environmental), physics, and electronics. The first resource of its kind, Gaseous Electronics: Tables, Atoms, and Molecules fulfills the author's vision of a stand-alone reference to condense 100 years of research on electron-neutral collision data into one easily searchable volume. It presents most--if not all--of the properly classified experimental results that scientists, researchers,

  6. The Frustrated Nerds Project--Resources for Systems Administrators in Higher Education: A Resource Webliography

    Science.gov (United States)

    Henninger, Jessamyn; Aber, Susan Ward

    2010-01-01

    Systems Architects and Information Technology administrators working in higher education help faculty, staff, and student computer users. Yet, who helps them? What resources do these professionals value? A case study was conducted using purposeful sampling and data collection through electronic interview to gather the preferred information-seeking…

  7. Human Resource Development in Hybrid Libraries

    OpenAIRE

    Prakasan, E. R.; Swarna, T.; Vijai Kumar, *

    2000-01-01

    This paper explores the human resources and development implications in hybrid libraries. Due to technological changes in libraries, which is a result of the proliferation of electronic resources, there has been a shift in workloads and workflow, requiring staff with different skills and educational backgrounds. Training of staff at all levels in information technology is the key to manage change, alleviate anxiety in the workplace and assure quality service in the libraries. Staff developmen...

  8. Procurement of novel microanalysis equipment for construction materials.

    Science.gov (United States)

    2012-02-01

    The equipment procured (i.e. an Orbis micro X-ray Fluorescence (MXRF) and an APSEX personal Scanning Electron Microscope (PSEM)) is part of the next generation of micro analytical equipment. These tools have the ability to make large volumes of...

  9. Preservation of and Permanent Access to Electronic Information Resources

    National Research Council Canada - National Science Library

    Hodge, Gail

    2004-01-01

    The rapid growth in the creation and dissemination of electronic information has emphasized the digital environment's speed and ease of dissemination with little regard for its long-term preservation and access...

  10. Magnesium: origin and role in calcium-treated inclusions

    CSIR Research Space (South Africa)

    Pistorius, PC

    2009-08-01

    Full Text Available Steel was sampled after calcium treatment at an industrial steel plant, and the inclusions identified by energy-dispersive X-ray microanalysis (EDX) on polished sections of the samples analysing the samples in a scanning electron microscope...

  11. Implementating Information Technology in E-Human Resource Management

    Directory of Open Access Journals (Sweden)

    Cristina-Dana Popescu (Mitu

    2016-01-01

    More and more organizations have been replacing face-to-face human resource managementactivities with electronic human resource management, which is considered as one of the keyfactors that every organization needs to focus. Considering that human resource management isone of the necessary needs of today’s business, the goal of this article is to establish the importanceof human resource management (HRM, to examine recent research in e-HRM in order to evaluatethe cumulated evidence on the relationship between HRM and e-HRM and to outline the impact ofe-HRM on human resource. Many specialists underlined the fact that human resource requiresmore attention and careful management than any other resource of an organization. This paperalso deals with the influence of Internet and information technology on work and human resourcemanagement.

  12. X-ray microanalysis of rotavirus-infected mouse intestine: A new concept of diarrhoeal secretion

    International Nuclear Information System (INIS)

    Spencer, A.J.; Osborne, M.P.; Haddon, S.J.; Collins, J.; Starkey, W.G.; Candy, D.C.; Stephen, J.

    1990-01-01

    Neonatal mice were infected at 7 days of age with rotavirus [epizootic diarrhea of infant mice (EDIM) virus] and killed at 24-h intervals postinfection (PI). Cytoplasmic concentrations of Na, Mg, P, S, Cl, K, and Ca intestinal epithelial cells from infected and age-matched control animals were measured by x-ray microanalysis. In villus tip cells, Ca concentration increased at 24-96 h PI; Na concentration increased at 24-72 h PI; Ca and Na concentrations were near normal by 168 h PI. K concentration decreased 24-72 h PI, and Cl concentration decreased 48-96 h PI. In crypt cells, changes were observed without a discernible pattern: at 96 h PI, Na, Mg, S, and Cl concentrations increased and K concentration decreased; at 120 h PI, the concentrations of all elements except Na and Ca increased. In villus base cells, the mean concentrations of all elements except Ca peaked at 48-72 h PI and at 120 h PI. Na and Cl concentrations increased dramatically in some cells from 48 h PI onward. All the above concentration values were obtained from freeze-dried specimens and expressed in millimoles per kilogram of dry weight. Conversion of a limited number of data, pertaining to villus base cells, from dry weight to wet weight was possible. This conversion revealed that villus base cells in infected animals were more hydrated than corresponding cells from control animals. Also, the Na and Cl concentrations in mmol/kg H2O were significantly higher in villus base cells from infected animals than in those from corresponding controls: 137 +/- 7 versus 38 +/- 4 (Na) and 121 +/- 5 versus 89 +/- 6 (Cl). Wet weight concentrations of other elements were either the same (Mg) or lower (P, S, and K) after infection with virus

  13. X-ray microanalysis of rotavirus-infected mouse intestine: A new concept of diarrhoeal secretion

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, A.J.; Osborne, M.P.; Haddon, S.J.; Collins, J.; Starkey, W.G.; Candy, D.C.; Stephen, J. (Univ. of Birmingham (England))

    1990-05-01

    Neonatal mice were infected at 7 days of age with rotavirus (epizootic diarrhea of infant mice (EDIM) virus) and killed at 24-h intervals postinfection (PI). Cytoplasmic concentrations of Na, Mg, P, S, Cl, K, and Ca intestinal epithelial cells from infected and age-matched control animals were measured by x-ray microanalysis. In villus tip cells, Ca concentration increased at 24-96 h PI; Na concentration increased at 24-72 h PI; Ca and Na concentrations were near normal by 168 h PI. K concentration decreased 24-72 h PI, and Cl concentration decreased 48-96 h PI. In crypt cells, changes were observed without a discernible pattern: at 96 h PI, Na, Mg, S, and Cl concentrations increased and K concentration decreased; at 120 h PI, the concentrations of all elements except Na and Ca increased. In villus base cells, the mean concentrations of all elements except Ca peaked at 48-72 h PI and at 120 h PI. Na and Cl concentrations increased dramatically in some cells from 48 h PI onward. All the above concentration values were obtained from freeze-dried specimens and expressed in millimoles per kilogram of dry weight. Conversion of a limited number of data, pertaining to villus base cells, from dry weight to wet weight was possible. This conversion revealed that villus base cells in infected animals were more hydrated than corresponding cells from control animals. Also, the Na and Cl concentrations in mmol/kg H2O were significantly higher in villus base cells from infected animals than in those from corresponding controls: 137 +/- 7 versus 38 +/- 4 (Na) and 121 +/- 5 versus 89 +/- 6 (Cl). Wet weight concentrations of other elements were either the same (Mg) or lower (P, S, and K) after infection with virus.

  14. Complementary Characterization of Cu(In,Ga)Se₂ Thin-Film Photovoltaic Cells Using Secondary Ion Mass Spectrometry, Auger Electron Spectroscopy, and Atom Probe Tomography.

    Science.gov (United States)

    Jang, Yun Jung; Lee, Jihye; Jeong, Jeung-Hyun; Lee, Kang-Bong; Kim, Donghwan; Lee, Yeonhee

    2018-05-01

    To enhance the conversion performance of solar cells, a quantitative and depth-resolved elemental analysis of photovoltaic thin films is required. In this study, we determined the average concentration of the major elements (Cu, In, Ga, and Se) in fabricated Cu(In,Ga)Se2 (CIGS) thin films, using inductively coupled plasma atomic emission spectroscopy, X-ray fluorescence, and wavelengthdispersive electron probe microanalysis. Depth profiling results for CIGS thin films with different cell efficiencies were obtained using secondary ion mass spectrometry and Auger electron spectroscopy to compare the atomic concentrations. Atom probe tomography, a characterization technique with sub-nanometer resolution, was used to obtain three-dimensional elemental mapping and the compositional distribution at the grain boundaries (GBs). GBs are identified by Na increment accompanied by Cu depletion and In enrichment. Segregation of Na atoms along the GB had a beneficial effect on cell performance. Comparative analyses of different CIGS absorber layers using various analytical techniques provide us with understanding of the compositional distributions and structures of high efficiency CIGS thin films in solar cells.

  15. Microstructure and microanalysis (SEM/EDX determination of glasses from Mallorca and Menorca caves

    Directory of Open Access Journals (Sweden)

    Rincón, Jesús María

    1993-12-01

    Full Text Available In recent years a field of research of growing interest has been the application of physico-chemical characterization methods on modern materials to the study of ancient materials found by the archaeologists. This new field on Materials Science is known as Archaeometry. Many questions about the origin and manufacture of ancient glasses can be solved by using the same methods of analysis and microstructure characterization applied normally to special and advanced glasses. The islands of Mallorca and Menorca, located in the Balearic archipelago in the Mediterranean sea, has long been a crossing place of cultures. Transparent, opal and coloured glasses have been found in various archaeological investigations carried out in these islands. In order to know the composition and microstructure of some of these glasses, an archaeometric study has been carried out using X-ray diffraction (XRD, transmission electron microscopy (TEM, scanning electron microscopy and energy-dispersive X-ray analysis (SEM/EDX, differential thermal analysis (DTA, and hot stage optical microscopy (HSM methods. The SEM/EDX average microanalysis results show that these glasses are deficient in sodium and highly enriched in Al2O3 and Fe2O3, their composition being in the range: 0.5-1.5 K2O, 8-10 CaO, 6-8 Al2O3, 6-8 Fe2O3, 74-76 SiO2 (wt%. Some of these glasses also contain high percentages of lead. Small quantities of TiO2, CuO and SO3 (0.5 % have also been detected. Surface decoration and blue colour are other features of these ancient glasses, the surface of which, depicted by SEM, is highly altered with flaked and corroded microstructures.

    En los últimos años la aplicación de los métodos físicoquímicos de caracterización de materiales modernos al estudio de materiales antiguos es un campo de investigación de creciente interés para

  16. Looking for Guidelines for the Production of Electronic Textbooks.

    Science.gov (United States)

    Landoni, M.; Wilson, R.; Gibb, F.

    2001-01-01

    Reports the results of two studies of electronic book production, including production on the World Wide Web, and explains EBONI (Electronic Books On-screen Interface) that focuses on the evaluation of electronic resources and compiling guidelines for publishing electronic materials on the Internet for the United Kingdom higher education…

  17. impact of the use of electronic resources on research output

    African Journals Online (AJOL)

    manda

    ... Julita Nawe. University of Dar Es Salaam Library, P.O. Box 35092, Dar Es Salaam, Tanzania .... significantly, while 28.3% observed that quality of service to the community had improved .... resources and evaluate them is an important area.

  18. Social Studies Online Resources. Media Corner.

    Science.gov (United States)

    Wilson, Jeri, Ed.

    1995-01-01

    Maintains that three types of social studies activities are found on the information highway: (1) electronic mail; (2) information; and (3) conferencing. Describes examples of each. Discusses commercial services and resource materials and provides references to online services. (CFR)

  19. Green Supply Chain Collaboration for Fashionable Consumer Electronics Products under Third-Party Power Intervention—A Resource Dependence Perspective

    Directory of Open Access Journals (Sweden)

    Jiuh-Biing Sheu

    2014-05-01

    Full Text Available Under third-party power intervention (TPPI, which increases uncertainty in task environments, complex channel power interplays and restructuring are indispensable among green supply chain members as they move toward sustainable collaborative relationships for increased viability and competitive advantage. From the resource dependence perspective, this work presents a novel conceptual model to investigate the influence of political and social power on channel power restructuring and induced green supply chain collaboration in brander-retailer bidirectional green supply chains of fashionable consumer electronics products (FCEPs. An FCEP refers to the consumer electronics product (e.g., personal computers, mobile phones, computer notebooks, and game consoles with the features of a well-known brand associated, a short product lifecycle, timely and fashionable design fit for market trends, and quick responsiveness to the variations of market demands. The proposed model is tested empirically using questionnaire data obtained from retailers in the FCEP brander-retailer distribution channels. Analytical results reveal that as an extension of political and social power, TPPI positively affects the reciprocal interdependence of dyadic members and reduces power asymmetry, thereby enhancing the collaborative relationship of dyadic members and leading to improved green supply chain performance. Therein, reciprocal interdependence underlying collaborative relationship is the key to reducing the external environmental uncertainties in the TPPI context.

  20. Channelling and related effects in electron microscopy: The current status

    International Nuclear Information System (INIS)

    Krishnan, K.M.

    1989-05-01

    Channelling or Borrmann effect in electron diffraction has been developed into a versatile, high spatial resolution, crystallographic technique with demonstrated applicability in solving a variety of materials problems. In general, either the characteristic x-ray emissions or the electron energy-loss intensities are monitored as a function of the orientation of the incident beam. The technique, as formulated in the planar geometry has found wide applications in specific site occupancy and valence measurements, determination of small atomic displacements and crystal polarity studies. For site occupancy studies, the appropriate orientations in most cases can be determined by inspection and the analysis carried out according to a simple classification of the crystal structure discussed in this paper. Concentration levels as low as 0.1 wt% can be easily detected. The reciprocity principle may be used to advantage in all these studies, if electron energy-loss spectra are monitored, as both the channelling of the incoming beam and the blocking of the outgoing beam are included in the formulation and analysis. The formulation in the axial geometry is an useful alternative, particularly for monatomic crystals. Localization effects are important if, either the experiment is performed in the axial geometry or if low atomic number elements (z < 11) are detected. In general, the sensitivity to L-shells is lower compared to K-shell excitations. Other experimental parameters to be considered include temperature of the sample, the acceleration voltage and parallelism of the incident beam. Any detrimental effects of channelling on conventional microanalysis can be minimized either by tilting the crystal to an orientation where no lower order diffraction vectors are excited or by using a convergent probe such that a large range of incident beam orientations are averaged in the analysis. 49 refs., 9 figs

  1. Chloride ingress in cement paste and mortar

    DEFF Research Database (Denmark)

    Jensen, Ole Mejlhede; Hansen, Per Freiesleben; Coats, Alison M.

    1999-01-01

    In this paper chloride ingress in cement paste and mortar is followed by electron probe microanalysis. The influence of several paste and exposure parameters on chloride ingress are examined (e.g., water-cement ratio, silica fume addition, exposure time, and temperature), The measurements...

  2. Pramana – Journal of Physics | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    The response of giant magnetoresistance (GMR) devices depends critically on the film microstructure, with parameters such as layer thickness and interfacial abruptness being crucial. This paper presents results obtained using high resolution electron microscopy (HREM), chemical mapping and atom probe microanalysis.

  3. Electron beam pasteurised oil palm waste: a potential feed resource

    International Nuclear Information System (INIS)

    Mat Rasol Awang; Hassan Hamdani Mutaat; Tamikazu Kume; Tachibana, H.

    2002-01-01

    Pasteurization of oil palm empty fruit bunch (EFB) was performed using electron beam single sided irradiation. The dose profiles of oil palm EFB samples for different thickness in both directions X and Y were established. The results showed the usual characteristics dose uniformity as sample thickness decreased. The mean average absorbed dose on both sides at the surface and bottom of the samples for different thickness samples lead to establishing depth dose curve. Based on depth dose curve and operation conditions of electron beam machine, the process throughput for pasteurized oil palm EFB were estimated. (Author)

  4. Hydroxyapatite-armored poly(ε-caprolactone) microspheres and hydroxyapatite microcapsules fabricated via a Pickering emulsion route.

    Science.gov (United States)

    Fujii, Syuji; Okada, Masahiro; Nishimura, Taiki; Maeda, Hayata; Sugimoto, Tatsuya; Hamasaki, Hiroyuki; Furuzono, Tsutomu; Nakamura, Yoshinobu

    2012-05-15

    Hydroxyapatite (HAp) nanoparticle-armored poly(ε-caprolactone) (PCL) microspheres were fabricated via a "Pickering-type" emulsion solvent evaporation method in the absence of any molecular surfactants. It was clarified that the interaction between carbonyl/carboxylic acid groups of PCL and the HAp nanoparticles at an oil-water interface played a crucial role in the preparation of the stable Pickering-type emulsions and the HAp nanoparticle-armored microspheres. The HAp nanoparticle-armored PCL microspheres were characterized in terms of size, size distribution, morphology, and chemical compositions using scanning electron microscopy, laser diffraction, energy dispersive X-ray microanalysis, and thermogravimetric analysis. The presence of HAp nanoparticles at the surface of the microspheres was confirmed by scanning electron microscopy and energy dispersive X-ray microanalysis. Pyrolysis of the PCL cores led to the formation of the corresponding HAp hollow microcapsules. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Microbeam X-ray analysis in Poland - past and future

    International Nuclear Information System (INIS)

    Kusinski, J

    2010-01-01

    The article provides an overview of the development of electron beam X-ray microanalysis (EPMA) in Poland. Since the introduction by Prof. Bojarski of EMPA over 45 years ago, tremendous advances in methodologies and in instrumentation have been made in order to improve the precision of quantitative compositional analysis, spatial resolution and analytical sensitivity. This was possible due to the activity of Applied Crystallography Committee at the Polish Academy of Sciences, as well as the groups of researches working in the Institute for Ferrous Metallurgy (Gliwice), the Technical University of Warsaw, the Silesian Technical University (Katowice), the AGH-University of Sciences and Technology (Krakow), and the Institute of Materials Science and Metallurgy Polish Academy of Sciences (Krakow). Based on the research examples realized by these teams, conferences, seminars and congresses organized, as well as books and academic textbooks issued, the evolution of electron beam X-ray microanalysis in Poland is demonstrated.

  6. The Use of Electronic Resources by Academic Staff at the University of Ilorin, Nigeria

    Science.gov (United States)

    Tella, Adeyinka; Orim, Faith; Ibrahim, Dauda Morenikeji; Memudu, Suleiman Ajala

    2018-01-01

    The use of e-resources is now commonplace among academics in tertiary educational institutions the world over. Many academics including those in the universities are exploring the opportunities of e-resources to facilitate teaching and research. As the use of e-resources is increasing particularly among academics at the University of Ilorin,…

  7. Building the electronic industry's roadmaps

    Science.gov (United States)

    Boulton, William R.

    1995-02-01

    JTEC panelists found a strong consistency among the electronics firms they visited: all the firms had clear visions or roadmaps for their research and development activities and had committed resources to ensure that they achieve targeted results. The overarching vision driving Japan's electronics industry is that of achieving market success through developing appealing, high-quality, low-cost consumer goods - ahead of the competition. Specifics of the vision include improving performance, quality, and portability of consumer electronics products. Such visions help Japanese companies define in detail the roadmaps they will follow to develop new and improved electronic packaging technologies.

  8. Study of the mass of the electron neutrino in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Yasumi, Shinjiro; Maezawa, Hideki [eds.

    1996-02-01

    This report describes a study of the mass of the electron neutrino using electron capture in {sup 163}Ho in Japan for the period from 1981 to 1994. This monograph has two purposes, one is to supplement the papers on the mass of the electron neutrino already published by us and another is to make a record on some details of our experiments for future. Electron capture in a nucleus takes place in a rather small space inside an atom, where atomic physics, nuclear physics and particle physics work closely together. Therefore, this study needed an intimate collaboration of atomic physicists, nuclear physicists and particle physicists. In addition, it was necessary for this study to use various fine techniques, including metallurgy, production of {sup 163}Ho activity, micro-analysis by wet chemistry, isotope-dilution mass spectrometry, undulator radiation source technology, the soft X-ray monochromator technology, a counting technique for very intense soft X-rays and so on. As a result, our collaboration consisted of many researchers from various fields as follows; M. Ando, H. Arai, M. Fujioka, N. Hashimoto, H. Ikeda, Y. Inagaki, K. Ishii, K. Itoh, G. Izawa, O. Kawakami, S. Kishimoto, H. Kitamura, H. Maezawa, M. Maruyama, A. Masuda, K. Masumoto, A. Mikuni, T. Mizogawa, T. Mukoyama, F. Ochiai, T. Ohta, T. Omori, G. Rajasekaran, K. Sera, K. Shima, T. Shinozuka, P.M. Stefan, I. Sugai, H. Taketani, M. Yagi, and S. Yasumi. Without such an excellent collaboration, this study would not have been completed. We would like to express our sincere gratitude to Professor T. Sasaki for supporting this study and recommending the undulator beam line of 2.5 GeV Photon Factory Storage Ring as a light source to be used in the experiment. We also would like to thank Dr. A. Yagishita and Dr. Y. Kitajima who are responsible for the BL-2 beamline. Finally we are grateful to Ms. M. Noji for her patient typewriting of manuscripts written by hand. (author).

  9. Study of the mass of the electron neutrino in Japan

    International Nuclear Information System (INIS)

    Yasumi, Shinjiro; Maezawa, Hideki

    1996-02-01

    This report describes a study of the mass of the electron neutrino using electron capture in 163 Ho in Japan for the period from 1981 to 1994. This monograph has two purposes, one is to supplement the papers on the mass of the electron neutrino already published by us and another is to make a record on some details of our experiments for future. Electron capture in a nucleus takes place in a rather small space inside an atom, where atomic physics, nuclear physics and particle physics work closely together. Therefore, this study needed an intimate collaboration of atomic physicists, nuclear physicists and particle physicists. In addition, it was necessary for this study to use various fine techniques, including metallurgy, production of 163 Ho activity, micro-analysis by wet chemistry, isotope-dilution mass spectrometry, undulator radiation source technology, the soft X-ray monochromator technology, a counting technique for very intense soft X-rays and so on. As a result, our collaboration consisted of many researchers from various fields as follows; M. Ando, H. Arai, M. Fujioka, N. Hashimoto, H. Ikeda, Y. Inagaki, K. Ishii, K. Itoh, G. Izawa, O. Kawakami, S. Kishimoto, H. Kitamura, H. Maezawa, M. Maruyama, A. Masuda, K. Masumoto, A. Mikuni, T. Mizogawa, T. Mukoyama, F. Ochiai, T. Ohta, T. Omori, G. Rajasekaran, K. Sera, K. Shima, T. Shinozuka, P.M. Stefan, I. Sugai, H. Taketani, M. Yagi, and S. Yasumi. Without such an excellent collaboration, this study would not have been completed. We would like to express our sincere gratitude to Professor T. Sasaki for supporting this study and recommending the undulator beam line of 2.5 GeV Photon Factory Storage Ring as a light source to be used in the experiment. We also would like to thank Dr. A. Yagishita and Dr. Y. Kitajima who are responsible for the BL-2 beamline. Finally we are grateful to Ms. M. Noji for her patient typewriting of manuscripts written by hand. (author)

  10. Mixed conduction protonic/electronic ceramic for high temperature electrolysis anode

    International Nuclear Information System (INIS)

    Goupil, Gregory

    2011-01-01

    This thesis validates the concept of mixed electron/proton ceramic conductors to be used as anode materials for intermediate temperature steam electrolyzer. The materials developed are based on cobaltites of alkaline-earth metals and rare earth elements commonly used for their high electronic conductivity in the temperature range of 300-600 C. The stability of each material has been assessed during 350 h in air and moist air. After checking the chemical compatibility with the BaZr 0.9 Y 0.1 O 3 electrolyte material, eight compositions have been selected: BaCoO 3 , LaCoO 3 , Sr 0.5 La 0.5 CoO 3 , Ba 0.5 La 0.5 CoO 3 , GdBaCo 2 O 5 , NdBaCo 2 O 5 , SmBaCo 2 O 5 and PrBaCo 2 O 5 . The thermal evolution of the oxygen stoichiometry of each material was determined by coupling iodo-metric titration and TGA in dry air. TGA in moist air has allowed determining the optimum temperature range for which proton incorporation is possible and maximized. Proton incorporation profiles have been determined on two cobaltites using SIMS and nuclear microanalysis in the ERDA configuration. Deuterium diffusion coefficients have been determined confirming the proton mobility in these materials. Under moist air, NdBaCo 2 O 5 is shown to incorporate rapidly a significant number of protons that spread homogeneously within the material bulk. Anode microstructure optimization has allowed reaching at 450 C and 600 C total resistance values on symmetrical cell highly promising. (author) [fr

  11. Resources to Manage a Private Practice.

    Science.gov (United States)

    Aigner, John; Cheek, Fredricka; Donati, Georgia; Zuravicky, Dori

    1997-01-01

    Includes four theme articles: "The Digital Toolkit: Electronic Necessities for Private Practice" (John Aigner); "Organizing a Private Practice: Forms, Fees, and Physical Set-up (Fredricka Cheek); "Career Development Resources: Guidelines for Setting Up a Private Practice Library" (Georgia Donati); and "Books to…

  12. Laboratory manual on sample preparation procedures for x-ray micro-analysis

    International Nuclear Information System (INIS)

    1997-01-01

    X-ray micro fluorescence is a non-destructive and sensitive method for studying the microscopic distribution of different elements in almost all kinds of samples. Since the beginning of this century, x-rays and electrons have been used for the analysis of many different kinds of material. Techniques which rely on electrons are mainly developed for microscopic studies, and are used in conventional Electron Microscopy (EM) or Scanning Electron Microscopy (SEM), while x-rays are widely used for chemical analysis at the microscopic level. The first chemical analysis by fluorescence spectroscopy using small x-ray beams was conducted in 1928 by Glockner and Schreiber. Since then much work has been devoted to developing different types of optical systems for focusing an x-ray beam, but the efficiency of these systems is still inferior to the conventional electron optical systems. However, even with a poor optical efficiency, the x-ray microbeam has many advantages compared with electron or proton induced x-ray emission methods. These include: The analyses are non-destructive, losses of mass are negligible, and due to the low thermal loading of x-rays, materials which may be thermally degraded can be analysed; Samples can be analysed in air, and no vacuum is required, therefore specimens with volatile components such as water in biological samples, can be imaged at normal pressure and temperature; No charging occurs during analysis and therefore coating of the sample with a conductive layer is not necessary; With these advantages, simpler sample preparation procedures including mounting and preservation can be used

  13. EDX microanalysis of neutron-irradiated alloys

    International Nuclear Information System (INIS)

    Thomas, L.E.

    1981-09-01

    Energy-dispersive X-ray (EDX) spectrometry of 50 nm thick specimens in the scanning transmission electron microscope provides quantitative elemental analyses of selected regions as small as 20 nm in diameter. To analyze highly radioactive neutron-irradiated alloys it is necessary to reduce the high counting deadtimes caused by energetic γ-Compton scattering in the Si(Li) detector, and to account for spurious background contributions from γ-rays and characteristic x-ray emissions. Several simple methods for overcoming effects of specimen radioactivity are described, including use of a tungsten collimator to attenuate γ and x-rays coming from the thick edges of self-supporting disk specimens. These methods allow analyses of Fe-Cr-Ni based alloys with γ-activities up to 1000 μC/sub i/. Techniques used to maintain high spatial resolution and accuracy in quantitatve analysis are also described, and their use is illustrated

  14. EPXMA survey of shelf sediments (Southern Bight, North Sea): A glance beyond the XRD-invisible

    NARCIS (Netherlands)

    De Maeyer-Worobiec, A.; Dekov, V.M.; Laane, R.W.P.M.; van Grieken, R.

    2009-01-01

    Shelf sediments of the southern North Sea, were studied with a microanalytical [electron probe X-ray microanalysis (EPXMA)] and two bulk [X-ray diffraction (XRD) and X-ray fluorescence (XRF)] techniques. The investigation proved that the promptness of the microanalytical method is combined with a

  15. Current status of electron beam treatment of flue gas in China

    International Nuclear Information System (INIS)

    Wang Zhiguang

    2006-01-01

    Fossil resource especially coal will remain the main energy resource in China over the next 3 ∼4 decades. Pollution of flue gas from fossil power station is one problem being desiderated to solve since 1990's. Electron beam treatment of flue gas as an advanced technique has been developed and used by some institutes and industries in China. The current status of flue gas treatment using electron beam and the development of electron accelerator in China are reviewed. (author)

  16. Characterization of leaf-level particulate matter for an industrial city using electron microscopy and X-ray microanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Sgrigna, G., E-mail: gregorio.sgrigna@ibaf.cnr.it [University of Molise (UniMol), Department of Biosciences and Territory, Contrada Fonte Lappone Pesche (Italy); Institute of Agro Environmental and Forest Biology, National Research Council (IBAF–CNR), Via Marconi, 2 Porano & Via Castellino 111, Napoli (Italy); Baldacchini, C., E-mail: chiara.baldacchini@ibaf.cnr.it [Institute of Agro Environmental and Forest Biology, National Research Council (IBAF–CNR), Via Marconi, 2 Porano & Via Castellino 111, Napoli (Italy); Esposito, R., E-mail: raffaela.esposito@ibaf.cnr.it [Institute of Agro Environmental and Forest Biology, National Research Council (IBAF–CNR), Via Marconi, 2 Porano & Via Castellino 111, Napoli (Italy); Calandrelli, R., E-mail: roberto.calandrelli@ibaf.cnr.it [Institute of Agro Environmental and Forest Biology, National Research Council (IBAF–CNR), Via Marconi, 2 Porano & Via Castellino 111, Napoli (Italy); Tiwary, A., E-mail: a.tiwary@soton.ac.uk [Faculty of Engineering and the Environment, University of Southampton, Highfield Campus, Southampton SO17 1BJ (United Kingdom); Calfapietra, C., E-mail: carlo.calfapietra@ibaf.cnr.it [Institute of Agro Environmental and Forest Biology, National Research Council (IBAF–CNR), Via Marconi, 2 Porano & Via Castellino 111, Napoli (Italy); Global Change Research Centre, Academy of Sciences of the Czech Republic, v. v. i., Bělidla 986/4a, 603 00 Brno (Czech Republic)

    2016-04-01

    This study reports application of monitoring and characterization protocol for particulate matter (PM) deposited on tree leaves, using Quercus ilex as a case study species. The study area is located in the industrial city of Terni in central Italy, with high PM concentrations. Four trees were selected as representative of distinct pollution environments based on their proximity to a steel factory and a street. Wash off from leaves onto cellulose filters were characterized using scanning electron microscopy and energy dispersive X-ray spectroscopy, inferring the associations between particle sizes, chemical composition, and sampling location. Modeling of particle size distributions showed a tri-modal fingerprint, with the three modes centered at 0.6 (factory related), 1.2 (urban background), and 2.6 μm (traffic related). Chemical detection identified 23 elements abundant in the PM samples. Principal component analysis recognized iron and copper as source-specific PM markers, attributed mainly to industrial and heavy traffic pollution respectively. Upscaling these results on leaf area basis provided a useful indicator for strategic evaluation of harmful PM pollutants using tree leaves. - Highlights: • Urban tree leaves were used for passive PM{sub 10} monitoring combining SEM and EDX analyses. • Particle mean diameter distributions were modeled by multimode lognormal functions. • Site-specific PM{sub 10} elemental composition was evaluated by principal component analysis. • PM profile (size and composition) was used to distinguish site-specific urban sources. • PM size and relative content of Cu and Fe emerged as possible pollutant source markers.

  17. The role of nitrogen and sulphur bearing compounds in the wettability of oil reservoir rocks: an approach with nuclear microanalysis and other related surface techniques

    International Nuclear Information System (INIS)

    Mercier, F.; Toulhoat, N.; Potocek, V.; Trocellier, P.

    1999-01-01

    Oil recovery is strongly influenced by the wettability of the reservoir rock. Some constituents of the crude oil (polar compounds and heavy fractions such as asphaltenes with heteroatoms) are believed to react with the reservoir rock and to condition the local wettability. Therefore, it is important to obtain as much knowledge as possible about the characteristics of the organic matter/mineral interactions. This study is devoted to the description at the microscopic scale of the distribution of some heavy fractions of crude oil (asphaltenes) and nitrogen molecules (pyridine and pyrrole) on model minerals of sandstone reservoir rocks such as silica and clays. Nuclear microanalysis, X-Ray Photoelectron Spectroscopy and other related microscopic imaging techniques allow to study the distribution and thickness of the organic films. The respective influences of the nature of the mineral substrate and the organic matter are studied. The important role played by the nitrogen compounds in the adsorption of organic matter is emphasized

  18. Microanalysis of vitrous char and associated polymers: reference and ancient assemblages

    Science.gov (United States)

    Allue, E.; Bonnamy, S.; Courty, M. M.; Gispert I Guirado, F.

    2012-12-01

    Formation of vitrous char that occur in ancient charcoal assemblages have remained unsolved. Laboratory experiments refuted vitrification to resulting from high temperature charring of green or resinous wood. This puzzling problem has been refreshed by showing the association to the charcoal and vitrous char of plastics that were originally supposed to only be produced by petroleum industry. Extraction of similar polymers within geological glassy products from cosmic airbursts has suggested impact processes to possibly forming the carbonaceous polymorphs. The pulverisation at the ground in the Angles village (French Eastern Pyrenees) following the 2011 August 2nd high altitude meteor explosion of exotic debris with vitrous char and polymers, just alike the puzzling ones of the geological and archaeological records, has provided potential reference materials. We present here their microanalysis by Environmental SEM with EDS, Raman micro-spectrometry and FTIR, XRD, TEM, ICP-MS and isotope analyses. The characterization helps elucidating how the carbonaceous polymorphs formed by transient heating and transient high pressure of atmospheric aerosols. Under TEM the vesicular, dense, vitrous char show high structural organization with a dense pattern of nano-sized graphitized domains, metals and mineral inclusions. The coupled Raman-ESEM has allowed identifying a complex pattern at micro scales of ordered "D" peak at 1320-1350 cm-1 and the graphitic, ordered peak at 1576-1590 cm-1, in association to amorphous and poorly graphitic ordered carbon. The later occurs within plant cells that have been extracted from the dense vitrous char by performing controlled combustion under nitrogen up to 1000°C. In contrast, the brittle, vesicular vitrous char and the polymers encountered at the rear of the pulverised airburst debris reveal to be formed of agglutinated micro spherules of amorphous carbon with rare crystallized carbon nano-domains and scattered mineral inclusions. They

  19. Where Doctors Read Health Information Resources and Their ...

    African Journals Online (AJOL)

    Resources Media Preferences. Obianuju E. ... The survey research design was adopted for the study. ... media of assessing health information are the internet, electronic databases, textbooks, journals and .... for Social Sciences (SPSS).

  20. eLearning resources to supplement postgraduate neurosurgery training.

    OpenAIRE

    Stienen, MN; Schaller, K; Cock, H; Lisnic, V; Regli, L; Thomson, S

    2017-01-01

    BACKGROUND: In an increasingly complex and competitive professional environment, improving methods to educate neurosurgical residents is key to ensure high-quality patient care. Electronic (e)Learning resources promise interactive knowledge acquisition. We set out to give a comprehensive overview on available eLearning resources that aim to improve postgraduate neurosurgical training and review the available literature. MATERIAL AND METHODS: A MEDLINE query was performed, using the search ter...

  1. Experimental observations elucidating the mechanisms of structural bcc-hcp transformations in ?-Ti alloys

    NARCIS (Netherlands)

    Van Bohemen, S.M.C.; Sietsma, J.; Van der Zwaag, S.

    2006-01-01

    The formation mechanisms of two hcp ? phase morphologies in Ti-4.5Fe-6.8Mo-1.5Al have been investigated by optical microscopy (OM), atomic force microscopy (AFM), electron probe microanalysis (EPMA) and dilatometry. At relatively high temperatures primary ? forms predominantly on prior bcc ? grain

  2. Use of backscattered electron imaging, X-ray microanalysis and X-ray microscopy in demonstrating physiological cell death

    International Nuclear Information System (INIS)

    Bowen, I.D.; Worrill, N.A.; Winters, C.A.; Mullarkey, K.

    1988-01-01

    The cytochemical localization of enzymatic activity by means of backscattered electron imaging (BEI) is reviewed and the application of BEI to changes in acid phosphatase and ATPase distribution during physiological (programmed) cell death in Heliothis midgut is explored. Programmed cell death entails the release of nascent free acid phosphatase as extracisternal hydrolase. This shift can readily be detected by means of the atomic number contrast imparted by BEI of the lead phosphatase reaction product, thus enabling the distribution of dying cells to be mapped. BEI is particularly useful in this context as it allows the examination of bulk specimens at low magnification. Death of cells is also accompanied by a collapse in ATPase activity which shows up as cytochemically negative areas in the X-ray microscope and by means of BEI. Acid phosphatase in normal cells is localized in the apical microvilli and lysosomes. Senescent or dying cells, however, clearly show a basally situated free hydrolase which migrates throughout the cell. Parallel TEM results confirm that this enzyme is ribosomal and extracisternal rather than lysosomal in origin. ATPase activity is largely limited to the apical microvilli, although there is some activity associated with the basal plasma membranes. The apical ATPase, however is partially resistant to ouabain. Young and mature cells are positive although in the latter case some microvilli may be lost as the cells acquire a negative cap or dome. Inhibition by bromotetramizole indicates that apical activity is not to any significant extent contributed to by alkaline phosphatase. Degenerate or dead cells are negative and can be seen as a mozaic of black patches among normal cells when imaged by means of BEI or X-ray microscopy

  3. Optimisation of mass ranging for atom probe microanalysis and application to the corrosion processes in Zr alloys

    International Nuclear Information System (INIS)

    Hudson, D.; Smith, G.D.W.; Gault, B.

    2011-01-01

    Atom probe tomography uses time-of-flight mass spectrometry to identify the chemical nature of atoms from their mass-to-charge-state ratios. Within a mass spectrum, ranges are defined so as to attribute a chemical identity to each peak. The accuracy of atom probe microanalysis relies on the definition of these ranges. Here we propose and compare several automated ranging techniques, tested against simulated mass spectra. The performance of these metrics compare favourably with a trial of users asked to manually range a simplified simulated dataset. The optimised automated ranging procedure was then used to precisely evaluate the very low iron concentration (0.003-0.018 at%) in a zirconium alloy to reveal its behaviour in the matrix during corrosion; oxygen is injected into solution and has the effect of increasing the local iron concentration near the oxide-metal interface, which in turn affects the corrosion properties of the metal substrate. -- Research Highlights: → Realistic simulated mass spectra were generated so as to reproduce experimental data with a perfectly determined composition. → Several metrics were tested against these simulated mass spectra to determine an optimal methodology for ranging mass peaks in atom probe tomography. Systematic automated ranging provides a significant reduction in the deviation between true and measured concentrations compared to manual ranging by multiple users on the same data. → Experimental datasets were subsequently investigated, and Fe has been shown to be distributed as a random solid solution within the matrix of 'as-received' recrystallised ZIRLO, a zirconium alloy.

  4. Oxidation states by X-ray fluorescence and electron probe microanalysis techniques

    International Nuclear Information System (INIS)

    Vazquez, Cristina; Riveros, J.A.

    1987-01-01

    Many years ago, several studies showed the effect of a chemical state in X-ray spectra. The effect, however, has rarely been utilized in quantitative chemical analysis. The purpose of this work is to show observed shifts due to different chemical states in iron compounds. (Author) [es

  5. Electronic Commerce: Government Services in the New Millennium.

    Science.gov (United States)

    Maxwell, Terrence A., Ed.

    1998-01-01

    This newsletter features innovations in resource management and information technology to support New York State government. The newsletter contains the following six sections: (1) "Electronic Commerce: Government Services in the New Millennium" -- examining the need for government involvement in electronic commerce policy and…

  6. Electronic Publishing Approaches to Curriculum: Videotex, Teletext and Databases.

    Science.gov (United States)

    Aumente, Jerome

    1986-01-01

    Describes the Journalism Resources Institute (JRI) of Rutgers University in terms of its administrative organization, computer resources, computer facilities use, involvement in electronic publishing, use of the Dow Jones News/Retrieval Database, curricular options, and professional continuing education. (AYC)

  7. PERii electronic journals: Assessing access and use by ...

    African Journals Online (AJOL)

    Peter G. Underwood

    institutional subscription to electronic journals through the Programme for Enhancement of .... These strategies include the promotion and marketing of these .... assist students and other library users to access PERii electronic journals resources. ..... Smith, H. Bukirwa, H. Mukasa, O. Snell, P. Adeh-Nsoh, S. Mbuyita, ...

  8. Mineralogical microanalysis of idiopathic pulmonary fibrosis

    International Nuclear Information System (INIS)

    Monso, E.; Tura, J.M.; Marsal, M.; Morell, F.; Pujadas, J.; Morera, J.

    1990-01-01

    A mineralogical analysis of lung tissue was conducted on 25 samples from patients who had been diagnosed as having idiopathic pulmonary fibrosis (IPF). Scanning electron microscopy (SEM) at low magnification and energy-dispersive x-ray analysis (EDXA) was used. In all samples, the surface silicon/sulfur (Si/S) ratio was calculated. The Si/S ratio for 25 samples of normal lung and 6 samples of pneumoconiotic lung was also determined (upper limit of normal Si/S ratio = 0.3). The difference between the Si/S ratio in the group with IPF and group with normal lung tissue was significantly significant (p less than .007, Wilcoxon test). Six of 12 patients with a previous diagnosis of IPF and a Si/S ratio greater than 0.3 had an exposure history that could imply inhalation of silica/silicates, and the correct diagnosis for these patients is most probably pneumoconiosis. The silica/silicate deposits detected in patients with IPF, and who had a ratio and no past exposure to dusts, could be either a cause or an effect of the disease

  9. Mineralogical microanalysis of idiopathic pulmonary fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Monso, E.; Tura, J.M.; Marsal, M.; Morell, F.; Pujadas, J.; Morera, J. (Hospital Germans Trias i Pujol, Badalona (Spain))

    1990-05-01

    A mineralogical analysis of lung tissue was conducted on 25 samples from patients who had been diagnosed as having idiopathic pulmonary fibrosis (IPF). Scanning electron microscopy (SEM) at low magnification and energy-dispersive x-ray analysis (EDXA) was used. In all samples, the surface silicon/sulfur (Si/S) ratio was calculated. The Si/S ratio for 25 samples of normal lung and 6 samples of pneumoconiotic lung was also determined (upper limit of normal Si/S ratio = 0.3). The difference between the Si/S ratio in the group with IPF and group with normal lung tissue was significantly significant (p less than .007, Wilcoxon test). Six of 12 patients with a previous diagnosis of IPF and a Si/S ratio greater than 0.3 had an exposure history that could imply inhalation of silica/silicates, and the correct diagnosis for these patients is most probably pneumoconiosis. The silica/silicate deposits detected in patients with IPF, and who had a ratio and no past exposure to dusts, could be either a cause or an effect of the disease.

  10. Quantitative characterization of the composition, thickness and orientation of thin films in the analytical electron microscope

    International Nuclear Information System (INIS)

    Williams, D.B.; Watanabe, M.; Papworth, A.J.; Li, J.C.

    2003-01-01

    Compositional variations in thin films can introduce lattice-parameter changes and thus create stresses, in addition to the more usual stresses introduced by substrate-film mismatch, differential thermal expansion, etc. Analytical electron microscopy comprising X-ray energy-dispersive spectrometry within a probe-forming field-emission gun scanning transmission electron microscope (STEM) is one of the most powerful methods of composition measurement on the nanometer scale, essential for thin-film analysis. Recently, with the development of improved X-ray collection efficiencies and quantitative computation methods it has proved possible to map out composition variations in thin films with a spatial resolution approaching 1-2 nm. Because the absorption of X-rays is dependent on the film thickness, concurrent composition and film thickness determination is another advantage of X-ray microanalysis, thus correlating thickness and composition variations, either of which may contribute to stresses in the film. Specific phenomena such as segregation to interfaces and boundaries in the film are ideally suited to analysis by X-ray mapping. This approach also permits multiple boundaries to be examined, giving some statistical certainty to the analysis particularly in nano-crystalline materials with grain sizes greater than the film thickness. Boundary segregation is strongly affected by crystallographic misorientation and it is now possible to map out the orientation between many different grains in the (S)TEM

  11. Electron microscopy and auger spectroscopy study of the wetting of the grain boundaries in the systems Mo-Pb, Mo-Sn, Mo-Ni and Ni-Pb; Etude par microscopie electronique et spectroscopie auger du mouillage des joints de grains dans les systemes Mo-Pb, Mo-Sn, Mo-Ni et Ni-Pb

    Energy Technology Data Exchange (ETDEWEB)

    Charai, A. [Faculte des Sciences et Techniques de Saint Jerome, Lab. TECSEN, UMR 6122 du CNRS, 13 - Marseille (France); Kutcherinenko, I.; Priester, L. [Paris-11 Univ., ISMA, 91 - Orsay (France); Penisson, J.M. [CEA Grenoble, Dept. de Recherche Fondamentale sur la Matiere Condensee, DRFMC-SP2M, 38 (France); Pontikis, V. [Centre National de la Recherche Scientifique (CNRS), Centre d' Etudes de Chimie Metallurgique, 94 - Vitry-sur-Seine (France); Wolski, K. [Ecole NationaleSuperieure des Mines de Saint Etienne, Centre SMS/MPI, URA 1884 du CNRS, 42 - Saint Etienne (France); Vystavel, T. [Academy of Sciences of Czech Republic, Institute of Physics, Praha (Czech Republic)

    2002-09-01

    Understanding the mechanism of the intergranular penetration of a liquid phase into a metallic solid is an important problem. The structural and chemical characterization of nano-metric films at grain boundaries is now possible by using high resolution electron microscopy associated with X-ray micro-analysis, electron energy loss spectroscopy and Auger spectroscopy. In order to study this problem, two different classes of model materials were selected according to their crystallographic structure: a bcc metal (molybdenum) and an fcc one (nickel). The wetting element was either lead or tin or nickel. In a first approach, the metallic matrix was polycrystalline. The conditions in which the liquid phase penetrates into the grain boundaries were studied by using special preparation and observation techniques. In particular, the use of a Focused Ion Beam microscope (FIB) allowed the preparation of thin foils located very precisely inside the matrix as well as multi-scale observations. These specimens were further observed in electron microscopy with a very high resolution. (authors)

  12. Oxy-schorl, Na(Fe2+2Al)Al6Si6O18(BO3)3(OH)3O, a new mineral from Zlatá Idka, Slovak Republic and Přibyslavice, Czech Republic

    Czech Academy of Sciences Publication Activity Database

    Bačík, P.; Cempírek, J.; Uher, P.; Novák, M.; Ozdín, D.; Filip, J.; Škoda, R.; Breiter, Karel; Klementová, Mariana; Ďuďa, R.; Groat, L. A.

    2013-01-01

    Roč. 98, 2/3 (2013), s. 485-492 ISSN 0003-004X Institutional support: RVO:67985831 ; RVO:68378271 Keywords : Oxy-schorl * tourmaline-supergroup minerals * new mineral * electron microanalysis * crystal-structure refinement * Přibyslavice * Zlatá Idka Subject RIV: DB - Geology ; Mineralogy Impact factor: 2.059, year: 2013

  13. Electronic Information – Threat or Challenge to Librarians and ...

    African Journals Online (AJOL)

    Electronic Information – Threat or Challenge to Librarians and Library Buildings. ... electronic resources because as new things and methods emerge, they exist ... that world trends in the paper industry and Internet use do not justify the fears ...

  14. Success factors for implementing and sustaining a mature electronic medical record in a low-resource setting: a case study of iSanté in Haiti.

    Science.gov (United States)

    deRiel, E; Puttkammer, N; Hyppolite, N; Diallo, J; Wagner, S; Honoré, J G; Balan, J G; Celestin, N; Vallès, J S; Duval, N; Thimothé, G; Boncy, J; Coq, N R L; Barnhart, S

    2018-03-01

    Electronic health information systems, including electronic medical records (EMRs), have the potential to improve access to information and quality of care, among other things. Success factors and challenges for novel EMR implementations in low-resource settings have increasingly been studied, although less is known about maturing systems and sustainability. One systematic review identified seven categories of implementation success factors: ethical, financial, functionality, organizational, political, technical and training. This case study applies this framework to iSanté, Haiti's national EMR in use in more than 100 sites and housing records for more than 750 000 patients. The author group, consisting of representatives of different agencies within the Haitian Ministry of Health (MSPP), funding partner the Centers for Disease Control and Prevention (CDC) Haiti, and implementing partner the International Training and Education Center for Health (I-TECH), identify successes and lessons learned according to the seven identified categories, and propose an additional cross-cutting category, sustainability. Factors important for long-term implementation success of complex information systems are balancing investments in hardware and software infrastructure upkeep, user capacity and data quality control; designing and building a system within the context of the greater eHealth ecosystem with a plan for interoperability and data exchange; establishing system governance and strong leadership to support local system ownership and planning for system financing to ensure sustainability. Lessons learned from 10 years of implementation of the iSanté EMR system are relevant to sustainability of a full range of increasingly interrelated information systems (e.g. for laboratory, supply chain, pharmacy and human resources) in the health sector in low-resource settings. © The Author 2017. Published by Oxford University Press in association with The London School of Hygiene

  15. A study on the utilization of serial resources in selected tertiary ...

    African Journals Online (AJOL)

    A study on the utilization of serial resources in selected tertiary institutions in Ogun State. ... Lagos Journal of Library and Information Science ... Serial resources are publications either in printed form or electronic format issued in successive parts usually having numerical or chronological designations and intended to be ...

  16. Modeling antecedents of electronic medical record system implementation success in low-resource setting hospitals.

    Science.gov (United States)

    Tilahun, Binyam; Fritz, Fleur

    2015-08-01

    With the increasing implementation of Electronic Medical Record Systems (EMR) in developing countries, there is a growing need to identify antecedents of EMR success to measure and predict the level of adoption before costly implementation. However, less evidence is available about EMR success in the context of low-resource setting implementations. Therefore, this study aims to fill this gap by examining the constructs and relationships of the widely used DeLone and MacLean (D&M) information system success model to determine whether it can be applied to measure EMR success in those settings. A quantitative cross sectional study design using self-administered questionnaires was used to collect data from 384 health professionals working in five governmental hospitals in Ethiopia. The hospitals use a comprehensive EMR system since three years. Descriptive and structural equation modeling methods were applied to describe and validate the extent of relationship of constructs and mediating effects. The findings of the structural equation modeling shows that system quality has significant influence on EMR use (β = 0.32, P quality has significant influence on EMR use (β = 0.44, P service quality has strong significant influence on EMR use (β = 0.36, P effect of EMR use on user satisfaction was not significant. Both EMR use and user satisfaction have significant influence on perceived net-benefit (β = 0.31, P mediating factor in the relationship between service quality and EMR use (P effect on perceived net-benefit of health professionals. EMR implementers and managers in developing countries are in urgent need of implementation models to design proper implementation strategies. In this study, the constructs and relationships depicted in the updated D&M model were found to be applicable to assess the success of EMR in low resource settings. Additionally, computer literacy was found to be a mediating factor in EMR use and user satisfaction of

  17. Application of ICT-based Learning Resources for University Inorganic Chemistry Course Training

    Directory of Open Access Journals (Sweden)

    Tatyana M. Derkach

    2013-01-01

    Full Text Available The article studies expediency and efficiency of various ICT-based learning resources use in university inorganic chemistry course training, detects difference of attitudes toward electronic resources between students and faculty members, which create the background for their efficiency loss

  18. Energy-dispersive X-ray microanalysis of elements' content and ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-05-18

    May 18, 2009 ... umbrosus, were collected from the Biodiversity Unit, Institute of. Bioscience (IBS), Universiti Putra Malaysia (UPM). Samples were cut into 1 X 1 mm, and mounted on Aluminium stub specimen holders and viewed under a variable pressure scanning electron microscope (VPSEM, EDX) model LEO1455 with ...

  19. Innovation and development of exhibition electronic-commerce based on the properties of electronic-commerce

    Science.gov (United States)

    Zhang, Jiankang

    2017-06-01

    There are two roadmaps of accomplishing exhibition electronic-commerce innovation and development. The first roadmap is that the exhibition organizers should seek mutual benefit cooperation with professional electronic-commerce platform of correspondent area with exhibition projects, thus help exhibitors realize their market object. The second roadmap is to promote innovation and development of electronic-commerce (Business-to-Customer) between both exhibitors and purchasers. Exhibition electronic-commerce must focus on innovative development in the following functions: market research and information service; advertising and business negotiation; online trading and online payment. With the aid of electronic-commerce, exhibition enterprise could have distinctive strengths such as transactions with virtualization, transparency, high efficiency and low cost, enhancing market link during enterprise research and development, promoting the efficiency of internal team collaboration and the individuation of external service, and optimizing resource allocation.

  20. 大學圖書館電子資源之需求分析與行銷策略之研究 A Study of Demands Analysis and Marketing Strategy of Electronic Resources in University Library

    Directory of Open Access Journals (Sweden)

    Huang-Yu Liu

    2008-03-01

    Full Text Available 電子資源的出現,使得知識載體有了新的突破,提高了使用者的便利性與即時性。對於圖書館而言,如何使電子資源的使用效益達到最高,必須思考一套有效的行銷策略。電子資源行銷概念應以讀者為導向,尊重讀者的資訊需求,並利用各種宣傳技巧,行銷電子資源,使圖書館能提供更完善的服務。本研究之目的旨在探討讀者的使用需求及電子資源的推廣策略,以獲致最有效益的行銷方式。研究對象以開南大學日間部四學院(商學院、運輸觀光學院、資訊學院、人文社會學院)學生為樣本,佐以缺口分析模型為分析架構,藉以找出個案中讀者/學生對於電子資源使用的真實需求,並進而歸納出提供服務的大學圖書館在其推廣或行銷服務上可有的因應策略。The emergence of electronic resources has made new breakthrough in knowledge carriers because of their ease of use, instant availability, and the characteristic of no time and space constraints. For public libraries to achieve maximum efficiency in its electronic resources, it is necessary to seek the most effective marketing strategies. Therefore, the marketing concept of the electronic resources should be reader oriented, such as respecting and understanding library user’s information needs. Libraries also need to utilize various media and techniques to market the electronic resources, so that more comprehensive services and experiences can be provided to readers. The purpose of this study is to investigate library user’s needs and promotion strategies of electronic resources in order to identify the most effective ways of marketing. This study focuses on the students of the four colleges (College of Business, College of Tourism, College of Information, and College of Humanities and Social Science in Kainan University as subjects in the survey questionnaire. It uses the Gap Analysis

  1. GENDER ANALYSIS OF ELECTRONIC INFORMATION

    African Journals Online (AJOL)

    use of internet Search engines such as google, yahoo and other free internet resources was found ... empirical studies are undertaken to examine the influence of gender ... H3: Perceived ease of use is positively related to the use of electronic.

  2. X-ray microanalysis of volcanic ash

    International Nuclear Information System (INIS)

    Kearns, S L; Buse, B

    2012-01-01

    The 2010 eruption of Eyjafjallajökull volcano in Iceland demonstrated the disruptive nature of high-level volcanic ash emissions to the world's air traffic. The chemistry of volcanic material is complex and varied. Different eruptions yield both compositional and morphological variation. Equally a single eruption, such as that in Iceland will evolve over time and may potentially produce a range of volcanic products of varying composition and morphology. This variability offers the petrologist the opportunity to derive a tracer to the origins both spatially and temporally of a single particle by means of electron microbeam analysis. EPMA of volcanic ash is now an established technique for this type of analysis as used in tephrachronology. However, airborne paniculate material may, as in the case of Eyjafjallajökull, result in a particle size that is too small and too dispersed for preparation of standard EPMA mounts. Consequently SEM-EDS techniques are preferred for this type of quantitative analysis . Results of quantitative SEM-EDS analysis yield data with a larger precision error than EPMA yet sufficient to source the original eruption. Uncoated samples analyzed using variable pressure SEM yield slightly poorer results at modest pressures.

  3. Electronics all-in-one for dummies

    CERN Document Server

    Lowe, Doug

    2011-01-01

    Take your electronics skills to the next level! If you're looking for a solitary resource that covers everything you need to know about electronics, then look no further. This friendly-and-straightforward guide introduces the basics of electronics and enhances your learning experience by debunking and explaining concepts such as circuits, analog and digital, schematics, voltage, safety concerns, and more. Packed with nearly 900 pages of detailed information, this book shows you how to develop your own breadboard, design your own circuit, and get savvy with schematics. Cover

  4. Evaluation of enamel by scanning electron microscopy green LED associated to hydrogen peroxide 35% for dental bleaching

    Science.gov (United States)

    Monteiro, Juliana S. C.; de Oliveira, Susana C. P. S.; Zanin, Fátima A. A.; Santos, Gustavo M. P.; Sampaio, Fernando J. P.; Gomes Júnior, Rafael Araújo; Gesteira, Maria F. M.; Vannier-Santos, Marcos A.; Pinheiro, Antônio Luiz B.

    2014-02-01

    Dental bleaching is a frequently requested procedure in clinical dental practice. The literature is contradictory regarding the effects of bleaching agents on both morphology and demineralization of enamel after bleaching. The aim of this study was to analyze by SEM the effect of 35% neutral hydrogen peroxide cured by green LED. Buccal surfaces of 15 pre-molars were sectioned and marked with a central groove to allow experimental and control groups on the same specimen. For SEM, 75 electron micrographs were evaluated by tree observers at 43X, 220X and 1000X. Quantitative analysis for the determination of the surface elemental composition of the samples through X-ray microanalysis by SEM was also performed. The protocol tested neither showed significant changes in mineral composition of the samples nor to dental enamel structure when compared to controls. SEM analysis allowed inferring that there were marked morphological differences between the enamel samples highlighting the need for the use of the same tooth in comparative morphological studies. The tested protocol did not cause morphological damage the enamel surface when compared to their respective controls.

  5. Microstructural characterization of an opal glass in the Na/sub 2/O-CdO-SiO/sub 2/ system

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, E; Celaya, L E; Rincon, J M

    1987-05-01

    The microstructure of an opal glass formulated in the ternary system Na/sub 2/O-CdO-SiO/sub 2/ has been determined by scanning electron microscopy (SEM) and energy dispersive X-ray microanalysis (EDX). This type of glass shows tridymite devitrification with a high level of liquid-liquid immiscibility.

  6. Electrical characteristics for Sn-Ag-Cu solder bump with Ti/Ni/Cu under-bump metallization after temperature cycling tests

    Science.gov (United States)

    Shih, T. I.; Lin, Y. C.; Duh, J. G.; Hsu, Tom

    2006-10-01

    Lead-free solder bumps have been widely used in current flip-chip technology (FCT) due to environmental issues. Solder joints after temperature cycling tests were employed to investigate the interfacial reaction between the Ti/Ni/Cu under-bump metallization and Sn-Ag-Cu solders. The interfacial morphology and quantitative analysis of the intermetallic compounds (IMCs) were obtained by electron probe microanalysis (EPMA) and field emission electron probe microanalysis (FE-EPMA). Various types of IMCs such as (Cu1-x,Agx)6Sn5, (Cu1-y,Agy)3Sn, and (Ag1-z,Cuz)3Sn were observed. In addition to conventional I-V measurements by a special sample preparation technique, a scanning electron microscope (SEM) internal probing system was introduced to evaluate the electrical characteristics in the IMCs after various test conditions. The electrical data would be correlated to microstructural evolution due to the interfacial reaction between the solder and under-bump metallurgy (UBM). This study demonstrated the successful employment of an internal nanoprobing approach, which would help further understanding of the electrical behavior within an IMC layer in the solder/UBM assembly.

  7. Electronic U.S. Government Information: Policy Issues and Directions.

    Science.gov (United States)

    Hernon, Peter; McClure, Charles R.

    1993-01-01

    Provides an overview of U.S. federal information policy and its treatment of electronic information resources. Highlights include government publications; electronic government information; main providers of government information, including the Government Printing Office; the Freedom of Information Act; public access and use; information…

  8. Connecting Print and Electronic Titles: An Integrated Approach at the University of Nebraska-Lincoln

    Science.gov (United States)

    Wolfe, Judith; Konecky, Joan Latta; Boden, Dana W. R.

    2011-01-01

    Libraries make heavy investments in electronic resources, with many of these resources reflecting title changes, bundled subsets, or content changes of formerly print material. These changes can distance the electronic format from its print origins, creating discovery and access issues. A task force was formed to explore the enhancement of catalog…

  9. The electronic Rothamsted Archive (e-RA), an online resource for data from the Rothamsted long-term experiments.

    Science.gov (United States)

    Perryman, Sarah A M; Castells-Brooke, Nathalie I D; Glendining, Margaret J; Goulding, Keith W T; Hawkesford, Malcolm J; Macdonald, Andy J; Ostler, Richard J; Poulton, Paul R; Rawlings, Christopher J; Scott, Tony; Verrier, Paul J

    2018-05-15

    The electronic Rothamsted Archive, e-RA (www.era.rothamsted.ac.uk) provides a permanent managed database to both securely store and disseminate data from Rothamsted Research's long-term field experiments (since 1843) and meteorological stations (since 1853). Both historical and contemporary data are made available via this online database which provides the scientific community with access to a unique continuous record of agricultural experiments and weather measured since the mid-19 th century. Qualitative information, such as treatment and management practices, plans and soil information, accompanies the data and are made available on the e-RA website. e-RA was released externally to the wider scientific community in 2013 and this paper describes its development, content, curation and the access process for data users. Case studies illustrate the diverse applications of the data, including its original intended purposes and recent unforeseen applications. Usage monitoring demonstrates the data are of increasing interest. Future developments, including adopting FAIR data principles, are proposed as the resource is increasingly recognised as a unique archive of data relevant to sustainable agriculture, agroecology and the environment.

  10. Internet resources and web pages for pediatric surgeons.

    Science.gov (United States)

    Lugo-Vicente, H

    2000-02-01

    The Internet, the largest network of connected computers, provides immediate, dynamic, and downloadable information. By re-architecturing the work place and becoming familiar with Internet resources, pediatric surgeons have anticipated the informatics capabilities of this computer-based technology creating a new vision of work and organization in such areas as patient care, teaching, and research. This review aims to highlight how Internet navigational technology can be a useful educational resource in pediatric surgery, examines web pages of interest, and defines ideas of network communication. Basic Internet resources are electronic mail, discussion groups, file transfer, and the Worldwide Web (WWW). Electronic mailing is the most useful resource extending the avenue of learning to an international audience through news or list-servers groups. Pediatric Surgery List Server, the most popular discussion group, is a constant forum for exchange of ideas, difficult cases, consensus on management, and development of our specialty. The WWW provides an all-in-one medium of text, image, sound, and video. Associations, departments, educational sites, organizations, peer-reviewed scientific journals and Medline database web pages of prime interest to pediatric surgeons have been developing at an amazing pace. Future developments of technological advance nurturing our specialty will consist of online journals, telemedicine, international chatting, computer-based training for surgical education, and centralization of cyberspace information into database search sites.

  11. In-capillary determination of creatinine with electrophoretically mediated microanalysis: characterization of the effects of reagent zone and buffer conditions.

    Science.gov (United States)

    Mason, Philip E; Schildt, Derek C; Strein, Timothy G

    2009-01-02

    Previous work has demonstrated proof-of-concept for carrying out the clinically useful Jaffe reaction between creatinine and picrate within a capillary tube using electrophoretically mediated microanalysis (EMMA). Here, it is shown that careful control of reagent plug length as well as concentration and pH of the background electrolyte (BGE) can result in a marked improvement in the sensitivity of this assay. Increasing the length of the picrate reagent zone is shown to give rise to as much as a 3-4-fold enhancement, and increasing the concentration and/or pH of the borate buffer also results in an additional, albeit modest, improvement in sensitivity. Interestingly, borate BGE concentrations approaching 100mM give rise to an unexplained drop in reaction efficiency, an effect which can be avoided by utilizing lower borate concentration with higher pH. The improvements appear to primarily minimize electrodispersion of the picrate reagent, allowing higher picrate concentration in the reaction zone. The same conditions also appear to minimize the electrodispersion of the in-line product as well. With optimized EMMA parameters, the sensitivity of the in-line Jaffe chemistry can be enhanced to an extent that there is no need for the two capillary "high sensitivity" detection system required in previous work. Using optimized conditions, three different human serum samples spanning the expected clinical range of creatinine concentrations were successfully analyzed. Overall, this work illustrates the importance of systematically characterizing the conditions under which EMMA analyses are carried out.

  12. PREFACE: European Microbeam Analysis Society's 14th European Workshop on Modern Developments and Applications in Microbeam Analysis (EMAS 2015), Portorož, Slovenia, 3-7 May 2015

    Science.gov (United States)

    Llovet, Xavier; Matthews, Michael B.; Čeh, Miran; Langer, Enrico; Žagar, Kristina

    2016-02-01

    This volume of the IOP Conference Series: Materials Science and Engineering contains papers from the 14th Workshop of the European Microbeam Analysis Society (EMAS) on Modern Developments and Applications in Microbeam Analysis which took place from the 3rd to the 7th of May 2015 in the Grand Hotel Bernardin, Portorož, Slovenia. The primary aim of this series of workshops is to assess the state-of-the-art and reliability of microbeam analysis techniques. The workshops also provide a forum where students and young scientists starting out on a career in microbeam analysis can meet and discuss with the established experts. The workshops have a unique format comprising invited plenary lectures by internationally recognized experts, poster presentations by the participants and round table discussions on the key topics led by specialists in the field.This workshop was organized in collaboration with the Jožef Stefan Institute and SDM - Slovene Society for Microscopy. The technical programme included the following topics: electron probe microanalysis, STEM and EELS, materials applications, cathodoluminescence and electron backscatter diffraction (EBSD), and their applications. As at previous workshops there was also a special oral session for young scientists. The best presentation by a young scientist was awarded with an invitation to attend the 2016 Microscopy and Microanalysis meeting at Columbus, Ohio. The prize went to Shirin Kaboli, of the Department of Metals and Materials Engineering of McGill University (Montréal, Canada), for her talk entitled "Electron channelling contrast reconstruction with electron backscattered diffraction". The continuing relevance of the EMAS workshops and the high regard in which they are held internationally can be seen from the fact that 71 posters from 16 countries were on display at the meeting and that the participants came from as far away as Japan, Canada, USA, and Australia. A selection of participants with posters was invited

  13. Chemical composition of individual aerosol particles from working areas in a nickel refinery.

    Science.gov (United States)

    Höflich, B L; Wentzel, M; Ortner, H M; Weinbruch, S; Skogstad, A; Hetland, S; Thomassen, Y; Chaschin, V P; Nieboer, E

    2000-06-01

    Individual aerosol particles (n = 1170) collected at work stations in a nickel refinery were analyzed by wavelength-dispersive electron-probe microanalysis. By placing arbitrary restrictions on the contents of sulfur and silicon, the particles could be divided into four main groups. Scanning electron images indicated that most of the particles examined were relatively small (refinery intermediates. The implications of the findings for aerosol speciation measurements, toxicological studies and interpretation of adverse health effects are explored.

  14. Gauging User Interest in Non-Traditional Library Resources

    Energy Technology Data Exchange (ETDEWEB)

    Sandberg, Tami; Abbott, Jennifer

    2015-06-23

    The National Renewable Energy Laboratory (NREL) is a government funded research laboratory based in Golden, Colorado. In addition to collecting traditional library resources such as journals, conference proceedings, and print and electronic books, the library also spends a significant portion of its collection development funds on resources not often found in many libraries: technical industry standards (e.g., ISO, IEC, ASTM, IEEE) and energy-related market reports. Assessing user needs for these resources is difficult for a number of reasons, particularly because standardized usage statistics are lacking or non-existent. Standards and market reports are generally costly and include fairly restrictive license agreements, which increase the importance of making informed collection development decisions. This presentation will discuss the NREL Library's current collection assessment and development practices as they relate to these unique resources.

  15. MendelWeb: An Electronic Science/Math/History Resource for the WWW.

    Science.gov (United States)

    Blumberg, Roger B.

    This paper describes a hypermedia resource, called MendelWeb that integrates elementary biology, discrete mathematics, and the history of science. MendelWeb is constructed from Gregor Menders 1865 paper, "Experiments in Plant Hybridization". An English translation of Mendel's paper, which is considered to mark the birth of classical and…

  16. Evaluation of the infection process by Lecanicillium fungicola in Agaricus bisporus by scanning electron microscopy.

    Science.gov (United States)

    Santana Nunes, Janaira; Rocha de Brito, Manuela; Cunha Zied, Diego; Aparecida das Graças Leite, Eloisa; Souza Dias, Eustáquio; Alves, Eduardo

    Lecanicillium fungicola causes dry bubble disease in Agaricus bisporus mushrooms leading to significant economic losses in commercial production. To monitor the infection process of L. fungicola in Brazilian strains of A. bisporus. The interaction between the mycelium of L. fungicola (LF.1) and three strains of A. bisporus (ABI 7, ABI 11/14 and ABI 11/21) was studied. Electron microscopy and X-ray microanalyses of vegetative growth and basidiocarp infection were evaluated. Micrographs show that the vegetative mycelium of the Brazilian strains of A. bisporus is not infected by the parasite. The images show that the pathogen can interlace the hyphae of A. bisporus without causing damage, which contributes to the presence of L. fungicola during the substrate colonization, allowing their presence during primordial formation of A. bisporus. In the basidiocarp, germ tubes form within 16h of infection with L. fungicola and the beginning of penetration takes place within 18h, both without the formation of specialized structures. Scanning electron microscopy enabled the process of colonization and reproduction to be observed within the formation of phialides, conidiophores and verticils of L. fungicola. The formation of calcium oxalate crystals by the pathogen was also visible using the X-ray microanalysis, both at the hyphae in the Petri plate and at basidiocarp infection site. Copyright © 2016 Asociación Española de Micología. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Helping Patrons Find Locally Held Electronic Resources: An Interlibrary Loan Perspective

    Science.gov (United States)

    Johnston, Pamela

    2016-01-01

    The University of North Texas Libraries provide extensive online access to academic journals through major vendor databases. As illustrated by interlibrary loan borrowing requests for items held in our databases, patrons often have difficulty navigating the available resources. In this study, the Interlibrary Loan staff used data gathered from the…

  18. Usability Testing for e-Resource Discovery: How Students Find and Choose e-Resources Using Library Web Sites

    Science.gov (United States)

    Fry, Amy; Rich, Linda

    2011-01-01

    In early 2010, library staff at Bowling Green State University (BGSU) in Ohio designed and conducted a usability study of key parts of the library web site, focusing on the web pages generated by the library's electronic resources management system (ERM) that list and describe the library's databases. The goal was to discover how users find and…

  19. EDUCATIONAL NETWORK RESOURCES IN JOURNALISM AND PUBLISHING: FEATURES OF THE SITES' CONTENT AND DESIGN

    Directory of Open Access Journals (Sweden)

    Hanna A. Zenzina

    2012-12-01

    Full Text Available The article deals with the concept of electronic educational resource, its importance for the orientation of students in cyberspace, the basic requirements for the design and content of educational resources eligibility criteria standards. Filed benefits of having their own educational resource for high school. Singled out the importance of the interaction of educational resources with social networks. Detected differences and similarities of design and content of educational resources of Kyiv Universities in journalism and publishing.

  20. Pramana – Journal of Physics | Indian Academy of Sciences

    Indian Academy of Sciences (India)

    An energy-dispersive electron probe X-ray microanalysis (ED-EPMA) technique using an energy-dispersive X-ray detector with an ultra-thin window, designated as low-Z particle EPMA, has been developed. The low-Z particle EPMA allows the quantitative determination of concentrations of low-Z elements such as C, N and ...

  1. Recycling-oriented characterization of plastic frames and printed circuit boards from mobile phones by electronic and chemical imaging

    International Nuclear Information System (INIS)

    Palmieri, Roberta; Bonifazi, Giuseppe; Serranti, Silvia

    2014-01-01

    Highlights: • A recycling oriented characterization of end-of-life mobile phones was carried out. • Characterization was developed in a zero-waste-perspective, aiming to recover all the mobile phone materials. • Plastic frames and printed circuit boards were analyzed by electronic and chemical imaging. • Suitable milling/classification strategies were set up to define specialized-pre-concentrated-streams. • The proposed approach can improve the recovery of polymers, base/precious metals, rare earths and critical raw materials. - Abstract: This study characterizes the composition of plastic frames and printed circuit boards from end-of-life mobile phones. This knowledge may help define an optimal processing strategy for using these items as potential raw materials. Correct handling of such a waste is essential for its further “sustainable” recovery, especially to maximize the extraction of base, rare and precious metals, minimizing the environmental impact of the entire process chain. A combination of electronic and chemical imaging techniques was thus examined, applied and critically evaluated in order to optimize the processing, through the identification and the topological assessment of the materials of interest and their quantitative distribution. To reach this goal, end-of-life mobile phone derived wastes have been systematically characterized adopting both “traditional” (e.g. scanning electronic microscopy combined with microanalysis and Raman spectroscopy) and innovative (e.g. hyperspectral imaging in short wave infrared field) techniques, with reference to frames and printed circuit boards. Results showed as the combination of both the approaches (i.e. traditional and classical) could dramatically improve recycling strategies set up, as well as final products recovery

  2. Recycling-oriented characterization of plastic frames and printed circuit boards from mobile phones by electronic and chemical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Palmieri, Roberta; Bonifazi, Giuseppe; Serranti, Silvia, E-mail: silvia.serranti@uniroma1.it

    2014-11-15

    Highlights: • A recycling oriented characterization of end-of-life mobile phones was carried out. • Characterization was developed in a zero-waste-perspective, aiming to recover all the mobile phone materials. • Plastic frames and printed circuit boards were analyzed by electronic and chemical imaging. • Suitable milling/classification strategies were set up to define specialized-pre-concentrated-streams. • The proposed approach can improve the recovery of polymers, base/precious metals, rare earths and critical raw materials. - Abstract: This study characterizes the composition of plastic frames and printed circuit boards from end-of-life mobile phones. This knowledge may help define an optimal processing strategy for using these items as potential raw materials. Correct handling of such a waste is essential for its further “sustainable” recovery, especially to maximize the extraction of base, rare and precious metals, minimizing the environmental impact of the entire process chain. A combination of electronic and chemical imaging techniques was thus examined, applied and critically evaluated in order to optimize the processing, through the identification and the topological assessment of the materials of interest and their quantitative distribution. To reach this goal, end-of-life mobile phone derived wastes have been systematically characterized adopting both “traditional” (e.g. scanning electronic microscopy combined with microanalysis and Raman spectroscopy) and innovative (e.g. hyperspectral imaging in short wave infrared field) techniques, with reference to frames and printed circuit boards. Results showed as the combination of both the approaches (i.e. traditional and classical) could dramatically improve recycling strategies set up, as well as final products recovery.

  3. Reliability criteria selection for integrated resource planning

    International Nuclear Information System (INIS)

    Ruiu, D.; Ye, C.; Billinton, R.; Lakhanpal, D.

    1993-01-01

    A study was conducted on the selection of a generating system reliability criterion that ensures a reasonable continuity of supply while minimizing the total costs to utility customers. The study was conducted using the Institute for Electronic and Electrical Engineers (IEEE) reliability test system as the study system. The study inputs and results for conditions and load forecast data, new supply resources data, demand-side management resource data, resource planning criterion, criterion value selection, supply side development, integrated resource development, and best criterion values, are tabulated and discussed. Preliminary conclusions are drawn as follows. In the case of integrated resource planning, the selection of the best value for a given type of reliability criterion can be done using methods similar to those used for supply side planning. The reliability criteria values previously used for supply side planning may not be economically justified when integrated resource planning is used. Utilities may have to revise and adopt new, and perhaps lower supply reliability criteria for integrated resource planning. More complex reliability criteria, such as energy related indices, which take into account the magnitude, frequency and duration of the expected interruptions are better adapted than the simpler capacity-based reliability criteria such as loss of load expectation. 7 refs., 5 figs., 10 tabs

  4. Power electronics for renewable energy systems

    DEFF Research Database (Denmark)

    Iov, Florin; Blaabjerg, Frede

    2009-01-01

    sources from the conventional, fossil (and short term) based energy sources to renewable energy resources. Another is to use high efficient power electronics in power generation, power transmission/distribution and end-user application. This paper discuss some of the most emerging renewable energy sources......, wind energy and photovoltaics, which by means of power electronics are changing from being minor energy sources to be acting as important power sources in the energy system....

  5. X-ray microanalysis of Plasmodium falciparum and infected red blood cells: effects of qinghaosu and chloroquine on potassium, sodium, and phosphorus composition

    International Nuclear Information System (INIS)

    Lee, P.; Ye, Z.; Van Dyke, K.; Kirk, R.G.

    1988-01-01

    Cryosections of human red blood cells infected by Plasmodium falciparum were analyzed by energy dispersive x-ray microanalysis to determine the elemental composition of the parasites and their red cell hosts separately. The effects of two antimalarial drugs, qinghaosu and chloroquine, on potassium, sodium, and phosphorus concentrations were studied. Malarial infection causes a decrease in potassium concentration and an increase in sodium concentration in the host red cells. The drastic change in the cation composition, however, occurs only in red cells infected by late stage parasites (late trophozoite and schizont). Red cells infected by early stage parasites (ring stage) show only small changes in sodium concentration. Furthermore, the noninfected red cells in parasitized cultures show no difference in composition from those of normal red cells. Treatment of the parasitized cultures with qinghaosu (10(-6) M) or chloroquine (10(-6) M) for 8 hr causes phosphorus concentration of both early and late parasites to decrease. An 8 hr treatment with qinghaosu also produces a reduction in potassium and an increase in sodium concentrations in early and late parasites. In contrast, 8 hr treatment with chloroquine only causes a change in the sodium and potassium concentrations of the late stage parasites and does not affect the early stage parasites

  6. School Building Design and Audio-Visual Resources.

    Science.gov (United States)

    National Committee for Audio-Visual Aids in Education, London (England).

    The design of new schools should facilitate the use of audiovisual resources by ensuring that the materials used in the construction of the buildings provide adequate sound insulation and acoustical and viewing conditions in all learning spaces. The facilities to be considered are: electrical services; electronic services; light control and…

  7. Free and Innovative Teaching Resources for STEM Educators

    Science.gov (United States)

    Weber, W. J.; McWhirter, J.; Dirks, D.

    2014-12-01

    The Unidata Program Center has implemented a teaching resource facility that allows educators to create, access, and share collections of resource material related to atmospheric, oceanic, and other earth system phenomena. While the facility can manage almost any type of electronic resource, it is designed with scientific data and products, teaching tools such as lesson plans and guided exercises, and tools for displaying data in mind. In addition to being very easy for educators and students to access, the facility makes it simple for other educators and scientists to contribute content related to their own areas of expertise to the collection. This allows existing teaching resources to grow in depth and breadth over time, enhancing their relevance and providing insights from multiple disciplines. Based on the open-source RAMADDA content/data management framework, the teaching resource facility provides a variety of built-in services to analyze and display data, as well as support for Unidata's rich 3D client, the Interactive Data Viewer (IDV).

  8. HELP (INFORMATION ELECTRONIC RESOURCE "CHRONICLE OF ONU: DATES, FACTS, EVENTS": HISTORY OF UNIVERSITY IN INFORMATION SPACE

    Directory of Open Access Journals (Sweden)

    А. М. Гавриленко

    2016-03-01

    Object of research is the help information resource "The chronicle of the Odessa national university of I. I. Mechnikov: dates, facts, events". The main objective of our article – to state the main methodological bases of creation of information resource. One of advantages of information resource is possibility of continuous updating and replenishment by new information. Main objective of creation of this information resource is systematization of material on stories of the Odessa national university of I. I. Mechnikov from the date of his basis to the present, ensuring interactive access to information on the main dates, the most significant events in life of university. The base of research are sources on the history of university, chronology of historical development, formation of infrastructure, cadres and scientific researches. In information resource the main stages of development, functioning and transformation of the Odessa University are analyzed, information on its divisions is collected. For creation of this information resource in Scientific library the method of work was developed, the main selection criteria of data are allocated. This information resource have practical value for all who is interested in history of university, historians, scientists-researchers of history of science and the city of Odessa.

  9. Electronic Journals in Academic Libraries: A Comparison of ARL and Non-ARL Libraries.

    Science.gov (United States)

    Shemberg, Marian; Grossman, Cheryl

    1999-01-01

    Describes a survey dealing with academic library provision of electronic journals and other electronic resources that compared ARL (Association of Research Libraries) members to non-ARL members. Highlights include full-text electronic journals; computers in libraries; online public access catalogs; interlibrary loan and electronic reserves; access…

  10. Particles and waves in electron optics and microscopy

    CERN Document Server

    Pozzi, Giulio

    2016-01-01

    Advances in Imaging and Electron Physics merges two long-running serials, Advances in Electronics and Electron Physics and Advances in Optical and Electron Microscopy. The series features extended articles on the physics of electron devices (especially semiconductor devices), particle optics at high and low energies, microlithography, image science, digital image processing, electromagnetic wave propagation, electron microscopy, and the computing methods used in all these domains. * Contains contributions from leading authorities on the subject matter* Informs and updates all the latest developments in the field of imaging and electron physics* Provides practitioners interested in microscopy, optics, image processing, mathematical morphology, electromagnetic fields, electron, and ion emission with a valuable resource* Features extended articles on the physics of electron devices (especially semiconductor devices), particle optics at high and low energies, microlithography, image science, and digital image pro...

  11. CLOUD EDUCATIONAL RESOURCES FOR PHYSICS LEARNING RESEARCHES SUPPORT

    Directory of Open Access Journals (Sweden)

    Oleksandr V. Merzlykin

    2015-10-01

    Full Text Available The definition of cloud educational resource is given in paper. Its program and information components are characterized. The virtualization as the technological ground of transforming from traditional electronic educational resources to cloud ones is reviewed. Such levels of virtualization are described: data storage device virtualization (Data as Service, hardware virtualization (Hardware as Service, computer virtualization (Infrastructure as Service, software system virtualization (Platform as Service, «desktop» virtualization (Desktop as Service, software user interface virtualization (Software as Service. Possibilities of designing the cloud educational resources system for physics learning researches support taking into account standards of learning objects metadata (accessing via OAI-PMH protocol and standards of learning tools interoperability (LTI are shown. The example of integration cloud educational resources into Moodle learning management system with use of OAI-PMH and LTI is given.

  12. QR Codes as Finding Aides: Linking Electronic and Print Library Resources

    Science.gov (United States)

    Kane, Danielle; Schneidewind, Jeff

    2011-01-01

    As part of a focused, methodical, and evaluative approach to emerging technologies, QR codes are one of many new technologies being used by the UC Irvine Libraries. QR codes provide simple connections between print and virtual resources. In summer 2010, a small task force began to investigate how QR codes could be used to provide information and…

  13. Power electronics basics operating principles, design, formulas, and applications

    CERN Document Server

    Rozanov, Yuriy; Chaplygin, Evgeny; Voronin, Pavel

    2015-01-01

    Power Electronics Basics: Operating Principles, Design, Formulas, and Applications provides fundamental knowledge for the analysis and design of modern power electronic devices. This concise and user-friendly resource:Explains the basic concepts and most important terms of power electronicsDescribes the power assemblies, control, and passive components of semiconductor power switchesCovers the control of power electronic devices, from mathematical modeling to the analysis of the electrical processesAddresses pulse-width modulation, power quality control, and multilevel, modular, and multicell

  14. Microanalytical investigation of fibre-reinforced ceramic materials

    International Nuclear Information System (INIS)

    Meier, B.; Grathwohl, G.

    1989-01-01

    Microanalytical investigations have been made on samples of ceramic fibres (SiC fibres, (Nicalon) C fibre coated with TiN) and fibre-reinforced ceramics (SiC-and glass-matrices). High resolution Auger electron spectroscopy (HRAES), electron probe microanalysis (EPMA) and scanning electron microscopy were employed for these examinations. Analysis was best performed with HRAES on account of its lateral and depth resolution. Some of the problems involved in this technique are discussed e.g. electron beam effects. AES depth profiles of ceramic fibres are reported and compared with the surface analysis of fibres in the composites after being broken in situ. (orig.)

  15. Print and Electronic Resources: Usage Statistics at Guru Gobind Singh Indraprastha University Library

    Science.gov (United States)

    Kapoor, Kanta

    2010-01-01

    Purpose: The purpose of this paper is to quantify the use of electronic journals in comparison with the print collections in the Guru Gobind Singh Indraprastha University Library. Design/methodology/approach: A detailed analysis was made of the use of lending services, the Xerox facility and usage of electronic journals such as Science Direct,…

  16. Investigation of the human spleen by X-ray microanalysis

    International Nuclear Information System (INIS)

    Kopani, M.; Jakubovsky, J.; Polak, S.

    2001-01-01

    Qualitative and quantitative topographic analysis using X-ray fluorescence (XRF), X-ray powder diffraction (XRD) and scanning electron microscopy was performed in tissue samples of rat and human spleens. The presence of silico-aluminium and silico-calcareous particles of various sizes could be seen. The presence of the inorganic substances mentioned in the human red pulp cords is assumed to be a consequence of the purifying function of the spleen. (Authors)

  17. On the Origins of Disorganized Attachment and Internal Working Models: Paper II. An Empirical Microanalysis of 4-Month Mother-Infant Interaction

    Science.gov (United States)

    Beebe, Beatrice; Lachmann, Frank; Markese, Sara; Buck, Karen A.; Bahrick, Lorraine E.; Chen, Henian; Cohen, Patricia; Andrews, Howard; Feldstein, Stanley; Jaffe, Joseph

    2012-01-01

    A microanalysis of 4-month mother-infant face-to-face communication predicted 12-month infant disorganized (vs. secure) attachment outcomes in an urban community sample. We documented a dyadic systems view of the roles of both partners, the roles of both self- and interactive contingency, and the importance of attention, orientation and touch, and as well as facial and vocal affect, in the co-construction of attachment disorganization. The analysis of different communication modalities identified striking intrapersonal and interpersonal intermodal discordance or conflict, in the context of intensely distressed infants, as the central feature of future disorganized dyads at 4 months. Lowered maternal contingent coordination, and failures of maternal affective correspondence, constituted maternal emotional withdrawal from distressed infants. This maternal withdrawal compromises infant interactive agency and emotional coherence. We characterize of the nature of emerging internal working models of future disorganized infants as follows: Future disorganized infants represent states of not being sensed and known by their mothers, particularly in moments of distress; they represent confusion about both their own and their mothers’ basic emotional organization, and about their mothers’ response to their distress. This internal working model sets a trajectory in development which may disturb the fundamental integration of the person. The remarkable specificity of our findings has the potential to lead to more finely-focused clinical interventions. PMID:23066334

  18. Oximato bridged Rh M and Rh M species (M = Mn, Co, Ni; M = Cu, Ag)

    Indian Academy of Sciences (India)

    WINTEC

    MnO6 coordination sphere is spanned by four oximato oxygen atoms and two water molecules lying in ... The manganese system displays a strong EPR signal near g = 2⋅00. In the ... Electronic and IR spectra were recorded ... Microanalysis (C, H, N) were performed us- .... Selected characterization data are given in the ex-.

  19. Preliminary Radiation Analysis of the Total Ionizing Dose for the Resource Prospector Mission

    Science.gov (United States)

    Rojdev, Kristina; Tylka, Allan J.; Atwell, William

    2015-01-01

    NASA's Resource Prospector (RP) is a collaborative project between multiple centers and institutions to search for volatiles at the polar regions of the Moon as a potential resource for oxygen and propellant production. The mission is rated Class D and will be the first In-Situ Resource Utilization (ISRU) demonstration on the lunar surface and at the lunar poles. Given that this mission is rated Class D, the project is considering using commercial off the shelf (COTS) electronics parts to reduce cost. However, COTS parts can be more susceptible to space radiation than typical aerospace electronic parts and carry some additional risk. Thus, prior to parts selection, having a better understanding of the radiation environment can assist designers in the parts selection process. The focus of this paper is to provide a preliminary analysis of the radiation environment from launch, through landing on the surface, and some surface stay as an initial step in determining worst case mission doses to assist designers in screening out electronic parts that would not meet the potential dose levels experienced on this mission.

  20. Global application of disorders of sex development-related electronic resources: e-learning, e-consultation and e-information sharing.

    Science.gov (United States)

    Muscarella, Miriam; Kranenburg-van Koppen, Laura; Grijpink-van den Biggelaar, Kalinka; Drop, Stenvert L S

    2014-01-01

    The past 20 years have seen proliferation of electronic (e) resources that promote improved understanding of disorders of sex development (DSD): e-learning for physicians and trainees, e-consultation between clinicians, and e-information for families and affected individuals. Recent e-learning advances have emerged from the European Society for Pediatric Endocrinology's online learning portal for current physicians and trainees. Developed with attention to developing clinical competencies incorporating learning theory, and presenting material that represents international best practice, this e-learning portal offers advances in training, making information more accessible for clinicians and trainees. Multiple levels of instruction, authentic case examples, collaborative forums for physicians and trainees, individualized feedback and user-friendly tools represent advances in trainee and physician learning that can take place in any location. e-consultation is an emerging tool that aims to connect physicians with specialists experienced in DSD care. Although it faces logistical challenges, e-consultation carries the potential to improve DSD care, especially in remote areas with limited access to DSD specialists. e-information for families and patients of all ages is widely accessible online, often with focus on DSD biology, medical care, and psychological and social support. e-information tools aid self-management and support of those affected by DSD. Efforts to improve these resources should aim to map information to individual users, incorporate optimally clear nomenclature, and continue as a 'shared enterprise' of clinicians, affected individuals, families and researchers. Improving the quality of DSD-related e-learning and e-information and developing e-consultation carries the potential to transform DSD care and support for patients, families and physicians worldwide. © 2014 S. Karger AG, Basel.