WorldWideScience

Sample records for methods neutron x-ray

  1. Non-destructive investigations of Swiss museums objects with neutron and x-ray imaging methods

    International Nuclear Information System (INIS)

    Lehmann, E.H.; Deschler, E.; Pernet, L.; Vontobel, P.

    2004-01-01

    Many objects of archaeological relevance found in Switzerland are from the Celtic and Roman era. Because of their uniqueness in most cases it is demanded to perform any investigation with such samples non-destructively. Depending on the structure and size of the objects a transmission experiment performed either with X-ray or neutron can alight inner structures, composition, defects or the principles of the manufacturing procedures. Furthermore, the treatment by conservators and restaurateurs becomes visible in many cases. This report describes some examples of such investigations. In the case of neutron investigations, beside the transmission imaging as a radiograph the three-dimensional structure was observed with a tomography technique. For X-ray radiography, the images were obtained in the same digital format because the similar experimental method (imaging plates) was applied. It becomes evident in the described examples that the combination and complementary use of both methods (neutrons and X-ray) brings insights in different aspects of the samples properties and treatment. This approach to study museums objects stored and exhibit in Switzerland can be extrapolated to other countries where these techniques are also simultaneously available in order to investigate other objects of relevance. The European network COST-G8 entitled 'Non-destructive analysis and testing of museum objects' can help to support initiatives in this direction. (author)

  2. Determinations of silicon and phosphorus in Pepperbush standard reference material by neutron activation and x-ray fluorescence methods

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Nishio, Hirofumi; Hayashi, Takeshi; Kusakabe, Toshio; Iwata, Shiro.

    1987-01-01

    Silicon and phosphorus contents in Pepperbush standard reference material were determined by neutron activation and X-ray fluorescence methods. In neutron activation analysis, β-ray spectra of 32 P produced by 31 P(n,γ) 32 P reaction on Pepperbush and standard samples were measured by a low background β-ray spectrometer. In X-ray fluorescence analysis, the standard samples were prepared by mixing the Pepperbush powder with silicon dioxide and diammonium hydrogenphosphate. Characteristic X-rays from the samples were analyzed by a wavelength dispersive X-ray fluorescence spectrometer. From the β and X-ray intensities, silicon and phosphorus contents in Pepperbush were determined to be 1840 ± 80 and 1200 ± 50 μg g -1 , respectively. (author)

  3. Physical methods for studying minerals and solid materials: X-ray, electron and neutron diffraction; scanning and transmission electron microscopy; X-ray, electron and ion spectrometry

    International Nuclear Information System (INIS)

    Eberhart, J.-P.

    1976-01-01

    The following topics are discussed: theoretical aspects of radiation-matter interactions; production and measurement of radiations (X rays, electrons, neutrons); applications of radiation interactions to the study of crystalline materials. The following techniques are presented: X-ray and neutron diffraction, electron microscopy, electron diffraction, X-ray fluorescence analysis, electron probe microanalysis, surface analysis by electron emission spectrometry (ESCA and Auger electrons), scanning electron microscopy, secondary ion emission analysis [fr

  4. Novel methods for measuring afterglow in developmental scintillators for X-ray and neutron detection

    Science.gov (United States)

    Bartle, C. M.; Edgar, A.; Dixie, L.; Varoy, C.; Piltz, R.; Buchanan, S.; Rutherford, K.

    2011-09-01

    In this paper we discuss two novel methods of measuring afterglow in scintillators. One method is designed for X-ray detection and the other for neutron detection applications. In the first method a commercial fan-beam scanner of basic design similar to those seen at airports is used to deliver a typically 12 ms long X-ray pulse to a scintillator by passing the test equipment through the scanner on the conveyor belt. In the second method the thermal neutron beam from a research reactor is incident on the scintillator. The beam is cut-off in about 1 ms using a 10B impregnated aluminum pneumatic shutter, and the afterglow is recorded on a dual range storage oscilloscope to capture both the steady state intensity and the weak decay. We describe these measurement methods and the results obtained for a range of developmental ceramic and glass scintillators, as well as some standard scintillators such as NaI(Tl), LiI(Eu) and the plastic scintillator NE102A. Preliminary modeling of the afterglow is presented.

  5. Novel methods for measuring afterglow in developmental scintillators for X-ray and neutron detection

    Energy Technology Data Exchange (ETDEWEB)

    Bartle, C.M., E-mail: m.bartle@gns.cri.nz [National Isotope Centre, GNS Science, PO Box 31312, Lower Hutt 5040 (New Zealand); Edgar, A.; Dixie, L.; Varoy, C. [School of Chemistry and Physics, Victoria University of Wellington, Wellington 6140 (New Zealand); Piltz, R. [Bragg Institute, ANSTO, PMB 1, Menai NSW 2234 (Australia); Buchanan, S.; Rutherford, K. [School of Chemistry and Physics, Victoria University of Wellington, Wellington 6140 (New Zealand)

    2011-09-21

    In this paper we discuss two novel methods of measuring afterglow in scintillators. One method is designed for X-ray detection and the other for neutron detection applications. In the first method a commercial fan-beam scanner of basic design similar to those seen at airports is used to deliver a typically 12 ms long X-ray pulse to a scintillator by passing the test equipment through the scanner on the conveyor belt. In the second method the thermal neutron beam from a research reactor is incident on the scintillator. The beam is cut-off in about 1 ms using a {sup 10}B impregnated aluminum pneumatic shutter, and the afterglow is recorded on a dual range storage oscilloscope to capture both the steady state intensity and the weak decay. We describe these measurement methods and the results obtained for a range of developmental ceramic and glass scintillators, as well as some standard scintillators such as NaI(Tl), LiI(Eu) and the plastic scintillator NE102A. Preliminary modeling of the afterglow is presented.

  6. Neutron and X-ray Spectroscopy

    CERN Document Server

    Hippert, Françoise; Hodeau, Jean Louis; Lelièvre-Berna, Eddy; Regnard, Jean-René

    2006-01-01

    Neutron and X-Ray Spectroscopy delivers an up-to-date account of the principles and practice of inelastic and spectroscopic methods available at neutron and synchrotron sources, including recent developments. The chapters are based on a course of lectures and practicals (the HERCULES course) delivered to young scientists who require these methods in their professional careers. Each chapter, written by a leading specialist in the field, introduces the basic concepts of the technique and provides an overview of recent work. This volume, which focuses on spectroscopic techniques in synchrotron radiation and inelastic neutron scattering, will be a primary source of information for physicists, chemists and materials scientists who wish to acquire a basic understanding of these techniques and to discover the possibilities offered by them. Emphasizing the complementarity of the neutron and X-ray methods, this tutorial will also be invaluable to scientists already working in neighboring fields who seek to extend thei...

  7. Application of the rigorous method to x-ray and neutron beam scattering on rough surfaces

    International Nuclear Information System (INIS)

    Goray, Leonid I.

    2010-01-01

    The paper presents a comprehensive numerical analysis of x-ray and neutron scattering from finite-conducting rough surfaces which is performed in the frame of the boundary integral equation method in a rigorous formulation for high ratios of characteristic dimension to wavelength. The single integral equation obtained involves boundary integrals of the single and double layer potentials. A more general treatment of the energy conservation law applicable to absorption gratings and rough mirrors is considered. In order to compute the scattering intensity of rough surfaces using the forward electromagnetic solver, Monte Carlo simulation is employed to average the deterministic diffraction grating efficiency due to individual surfaces over an ensemble of realizations. Some rules appropriate for numerical implementation of the theory at small wavelength-to-period ratios are presented. The difference between the rigorous approach and approximations can be clearly seen in specular reflectances of Au mirrors with different roughness parameters at wavelengths where grazing incidence occurs at close to or larger than the critical angle. This difference may give rise to wrong estimates of rms roughness and correlation length if they are obtained by comparing experimental data with calculations. Besides, the rigorous approach permits taking into account any known roughness statistics and allows exact computation of diffuse scattering.

  8. X-rays from neutron stars

    International Nuclear Information System (INIS)

    Boerner, G.

    1979-08-01

    The basic theoretical in the models of regularly pulsating X-ray sources are discussed, and put in relation to the observations. The topics covered include physics of the magnetosphere of an accreting neutron star, hydrodynamics of the accretion column, physical processes close to the surface of the neutron star such as proton-electron collisions, photon-electron interactions. (orig.)

  9. Neutron and X-ray optics

    CERN Document Server

    Cremer, Jay Theodore

    2013-01-01

    Covering a wide range of topics related to neutron and x-ray optics, this book explores the aspects of neutron and x-ray optics and their associated background and applications in a manner accessible to both lower-level students while retaining the detail necessary to advanced students and researchers. It is a self-contained book with detailed mathematical derivations, background, and physical concepts presented in a linear fashion. A wide variety of sources were consulted and condensed to provide detailed derivations and coverage of the topics of neutron and x-ray optics as well as the background material needed to understand the physical and mathematical reasoning directly related or indirectly related to the theory and practice of neutron and x-ray optics. The book is written in a clear and detailed manner, making it easy to follow for a range of readers from undergraduate and graduate science, engineering, and medicine. It will prove beneficial as a standalone reference or as a complement to textbooks. Su...

  10. Neutron activation analysis. Criterion method for evaluation of dual-energy x-ray absorptiometry measurements in infants

    International Nuclear Information System (INIS)

    Ellis, K.J.; Shypailo, R.J.; Schoknecht, P.; Pond, W.G.

    1995-01-01

    Total body neutron activation analysis (NAA) was used to examine the elemental composition of 22 piglets in the weight range 0.7 kg to 3.4 kg. The accuracy of the NAA technique, compared to direct chemical carcass analysis, established it as an equivalent chemical criterion (reference) method. The body composition of 14 human infant cadavers was also examined by NAA and by dual-energy x-ray absorptiometry (DXA). The DXA-derived lean, fat, and bone compartments were compared with an NAA chemical model of composition. Each of the three compartments was significantly correlated (r=0.85-0.95.p<0.001) for the two independent assay, although there were substantial differences for the estimated size of the compartments for individual infants. (author). 11 refs., 2 figs., 2 tabs

  11. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    The Basic Energy Sciences (BES) X-ray and neutron user facilities attract more than 12,000 researchers each year to perform cutting-edge science at these state-of-the-art sources. While impressive breakthroughs in X-ray and neutron sources give us the powerful illumination needed to peer into the nano- to mesoscale world, a stumbling block continues to be the distinct lag in detector development, which is slowing progress toward data collection and analysis. Urgently needed detector improvements would reveal chemical composition and bonding in 3-D and in real time, allow researchers to watch “movies” of essential life processes as they happen, and make much more efficient use of every X-ray and neutron produced by the source The immense scientific potential that will come from better detectors has triggered worldwide activity in this area. Europe in particular has made impressive strides, outpacing the United States on several fronts. Maintaining a vital U.S. leadership in this key research endeavor will require targeted investments in detector R&D and infrastructure. To clarify the gap between detector development and source advances, and to identify opportunities to maximize the scientific impact of BES user facilities, a workshop on Neutron and X-ray Detectors was held August 1-3, 2012, in Gaithersburg, Maryland. Participants from universities, national laboratories, and commercial organizations from the United States and around the globe participated in plenary sessions, breakout groups, and joint open-discussion summary sessions. Sources have become immensely more powerful and are now brighter (more particles focused onto the sample per second) and more precise (higher spatial, spectral, and temporal resolution). To fully utilize these source advances, detectors must become faster, more efficient, and more discriminating. In supporting the mission of today’s cutting-edge neutron and X-ray sources, the workshop identified six detector research challenges

  12. Hard X ray lines from neutron stars

    Energy Technology Data Exchange (ETDEWEB)

    Polcaro, V.F.; Bazzano, A.; La Padula, C.; Ubertini, P.

    1982-01-01

    Experimental evidence is presented and evaluated concerning the features of the hard X-ray spectra detected in a number of cosmic X-ray sources which contain a neutron star. The strong emission line at cyclotron resonance detected in the spectrum of Her XI at an energy of 58 keV is evaluated and the implications of this finding are discussed. Also examined is the presence of spectral features in the energy range 20-80 keV found in the spectra of gamma-ray bursts, which have been interpreted as cyclotron resonance from interstellar-gas-accreting neutron stars. The less understood finding of a variable emission line at approximately 70 keV in the spectrum of the Crab Pulsar is considered. It is determined that several features varying with time are present in the spectra of cosmic X-ray sources associated with neutron stars. If these features are due to cyclotron resonance, it is suggested that they provide a direct measurement of neutron star magnetic fields on the order of 10 to the 11th-10 to the 13th Gauss. However, the physical condition of the emitting region and its geometry are still quite obscure.

  13. Instrument and method for focusing X-rays, gamma rays and neutrons

    International Nuclear Information System (INIS)

    1982-01-01

    A crystal diffraction instrument is described with an improved crystalline structure having a face for receiving a beam of photons or neutrons and diffraction planar spacing along that face with the spacing increasing progressively along the face to provide a decreasing Bragg angle and thereby increasing the usable area and acceptance angle. The increased planar spacing is provided by the use of a temperature differential across the crystalline structure, by assembling a plurality of crystalline structure with different compositions, by an individual crystalline structure with a varying composition and thereby a changing planar spacing along its face, and by combinations of these techniques. (Auth.)

  14. Analysis of neutron and x-ray reflectivity data by constrained least-squares methods

    DEFF Research Database (Denmark)

    Pedersen, J.S.; Hamley, I.W.

    1994-01-01

    . The coefficients in the series are determined by constrained nonlinear least-squares methods, in which the smoothest solution that agrees with the data is chosen. In the second approach the profile is expressed as a series of sine and cosine terms. A smoothness constraint is used which reduces the coefficients...

  15. Assessment of firing conditions in old fired-clay bricks. The contribution of X-ray powder diffraction with the Rietveld method and small angle neutron scattering

    Czech Academy of Sciences Publication Activity Database

    Viani, Alberto; Sotiriadis, Konstantinos; Len, A.; Šašek, Petr; Ševčík, Radek

    2016-01-01

    Roč. 116, June (2016), s. 33-43 ISSN 1044-5803 R&D Projects: GA MŠk(CZ) LO1219 Keywords : fired- clay brick * Rietveld method * small angle neutron scattering * X-ray diffraction * firing temperature Subject RIV: AL - Art, Architecture, Cultural Heritage Impact factor: 2.714, year: 2016 http://www.sciencedirect.com/science/article/pii/S1044580316300870

  16. Modern Developments in X-Ray and Neutron Optics

    CERN Document Server

    Erko, Alexei; Krist, Thomas; Michette, Alan G

    2008-01-01

    This volume describes modern developments in reflective, refractive and diffractive optics for short wavelength radiation as well as recent theoretical approaches to modelling and ray-tracing the X-ray and neutron optical systems. It is based on the joint research activities of specialists in X-ray and neutron optics from 11 countries, working together under the framework of the European Programme for Cooperation in Science and Technology (COST, Action P7) in the period 2002--2006. The chapters are written by leading specialists from European laboratories, universities and large facilities. In addition to new ideas and concepts, the contents provide a large amount of practical information about recently implemented devices and methods.

  17. Method for spatially modulating X-ray pulses using MEMS-based X-ray optics

    Science.gov (United States)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2015-03-10

    A method and apparatus are provided for spatially modulating X-rays or X-ray pulses using microelectromechanical systems (MEMS) based X-ray optics. A torsionally-oscillating MEMS micromirror and a method of leveraging the grazing-angle reflection property are provided to modulate X-ray pulses with a high-degree of controllability.

  18. MODEL ATMOSPHERES FOR X-RAY BURSTING NEUTRON STARS

    International Nuclear Information System (INIS)

    Medin, Zach; Fontes, Christopher J.; Fryer, Chris L.; Hungerford, Aimee L.; Steinkirch, Marina von; Calder, Alan C.

    2016-01-01

    The hydrogen and helium accreted by X-ray bursting neutron stars is periodically consumed in runaway thermonuclear reactions that cause the entire surface to glow brightly in X-rays for a few seconds. With models of the emission, the mass and radius of the neutron star can be inferred from the observations. By simultaneously probing neutron star masses and radii, X-ray bursts (XRBs) are one of the strongest diagnostics of the nature of matter at extremely high densities. Accurate determinations of these parameters are difficult, however, due to the highly non-ideal nature of the atmospheres where XRBs occur. Observations from X-ray telescopes such as RXTE and NuStar can potentially place strong constraints on nuclear matter once uncertainties in atmosphere models have been reduced. Here we discuss current progress on modeling atmospheres of X-ray bursting neutron stars and some of the challenges still to be overcome.

  19. MODEL ATMOSPHERES FOR X-RAY BURSTING NEUTRON STARS

    Energy Technology Data Exchange (ETDEWEB)

    Medin, Zach; Fontes, Christopher J.; Fryer, Chris L.; Hungerford, Aimee L. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Steinkirch, Marina von; Calder, Alan C. [Department of Physics and Astronomy, Stony Brook University, Stony Brook, NY 11794 (United States)

    2016-12-01

    The hydrogen and helium accreted by X-ray bursting neutron stars is periodically consumed in runaway thermonuclear reactions that cause the entire surface to glow brightly in X-rays for a few seconds. With models of the emission, the mass and radius of the neutron star can be inferred from the observations. By simultaneously probing neutron star masses and radii, X-ray bursts (XRBs) are one of the strongest diagnostics of the nature of matter at extremely high densities. Accurate determinations of these parameters are difficult, however, due to the highly non-ideal nature of the atmospheres where XRBs occur. Observations from X-ray telescopes such as RXTE and NuStar can potentially place strong constraints on nuclear matter once uncertainties in atmosphere models have been reduced. Here we discuss current progress on modeling atmospheres of X-ray bursting neutron stars and some of the challenges still to be overcome.

  20. Model Atmospheres for X-ray Bursting Neutron Stars

    OpenAIRE

    Medin, Zach; von Steinkirch, Marina; Calder, Alan C.; Fontes, Christopher J.; Fryer, Chris L.; Hungerford, Aimee L.

    2016-01-01

    The hydrogen and helium accreted by X-ray bursting neutron stars is periodically consumed in runaway thermonuclear reactions that cause the entire surface to glow brightly in X-rays for a few seconds. With models of the emission, the mass and radius of the neutron star can be inferred from the observations. By simultaneously probing neutron star masses and radii, X-ray bursts are one of the strongest diagnostics of the nature of matter at extremely high densities. Accurate determinations of t...

  1. Comparing neutron and X-ray images from NIF implosions

    Directory of Open Access Journals (Sweden)

    Wilson D.C.

    2013-11-01

    Full Text Available Directly laser driven and X-radiation driven DT filled capsules differ in the relationship between neutron and X-ray images. Shot N110217, a directly driven DT-filled glass micro-balloon provided the first neutron images at the National Ignition Facility. As seen in implosions on the Omega laser, the neutron image can be enclosed inside time integrated X-ray images. HYDRA simulations show the X-ray image is dominated by emission from the hot glass shell while the neutron image arises from the DT fuel it encloses. In the absence of mix or jetting, X-ray images of a cryogenically layered THD fuel capsule should be dominated by emission from the hydrogen rather than the cooler plastic shell that is separated from the hot core by cold DT fuel. This cool, dense DT, invisible in X-ray emission, shows itself by scattering hot core neutrons. Germanium X-ray emission spectra and Ross pair filtered X-ray energy resolved images suggest that germanium doped plastic emits in the torus shaped hot spot, probably reducing the neutron yield.

  2. Two methods for studying the X-ray variability

    NARCIS (Netherlands)

    Yan, Shu-Ping; Ji, Li; Méndez, Mariano; Wang, Na; Liu, Siming; Li, Xiang-Dong

    2016-01-01

    The X-ray aperiodic variability and quasi-periodic oscillation (QPO) are the important tools to study the structure of the accretion flow of X-ray binaries. However, the origin of the complex X-ray variability from X-ray binaries remains yet unsolved. We proposed two methods for studying the X-ray

  3. Improving material identification by combining x-ray and neutron tomography

    Science.gov (United States)

    LaManna, Jacob M.; Hussey, Daniel S.; Baltic, Eli; Jacobson, David L.

    2017-09-01

    X-rays and neutrons provide complementary non-destructive probes for the analysis of structure and chemical composition of materials. Contrast differences between the modes arise due to the differences in interaction with matter. Due to the high sensitivity to hydrogen, neutrons excel at separating liquid water or hydrogenous phases from the underlying structure while X-rays resolve the solid structure. Many samples of interest, such as fluid flow in porous materials or curing concrete, are stochastic or slowly changing with time which makes analysis of sequential imaging with X-rays and neutrons difficult as the sample may change between scans. To alleviate this issue, NIST has developed a system for simultaneous X-ray and neutron tomography by orienting a 90 keVpeak micro-focus X-ray tube orthogonally to a thermal neutron beam. This system allows for non-destructive, multimodal tomography of dynamic or stochastic samples while penetrating through sample environment equipment such as pressure and flow vessels. Current efforts are underway to develop methods for 2D histogram based segmentation of reconstructed volumes. By leveraging the contrast differences between X-rays and neutrons, greater histogram peak separation can occur in 2D vs 1D enabling improved material identification.

  4. Assessment of firing conditions in old fired-clay bricks: The contribution of X-ray powder diffraction with the Rietveld method and small angle neutron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Viani, Alberto, E-mail: viani@itam.cas.cz [Institute of Theoretical and Applied Mechanics AS CR, Centre of Excellence Telč, Batelovská 485, CZ-58856 Telč (Czech Republic); Sotiriadis, Konstantinos [Institute of Theoretical and Applied Mechanics AS CR, Centre of Excellence Telč, Batelovská 485, CZ-58856 Telč (Czech Republic); Len, Adél [Wigner Research Centre for Physics HAS, Konkoly-Thege 29-33, 1121 Budapest (Hungary); Šašek, Petr; Ševčík, Radek [Institute of Theoretical and Applied Mechanics AS CR, Centre of Excellence Telč, Batelovská 485, CZ-58856 Telč (Czech Republic)

    2016-06-15

    Full characterization of fired-clay bricks is crucial for the improvement of process variables in manufacturing and, in case of old bricks, for restoration/replacement purposes. To this aim, five bricks produced in a plant in Czech Republic in the past have been investigated with a combination of analytical techniques in order to derive information on the firing process. An additional old brick from another brickyard was also used to study the influence of different raw materials on sample microstructure. The potential of X-ray diffraction with the Rietveld method and small angle neutron scattering technique has been exploited to describe the phase transformations taking place during firing and characterize the brick microstructure. Unit-cell parameter of spinel and amount of hematite are proposed as indicators of the maximum firing temperature, although for the latter, limited to bricks produced from the same raw material. The fractal quality of the surface area of pores obtained from small angle neutron scattering is also suggested as a method to distinguish between bricks produced from different raw clays. - Highlights: • Rietveld method helps in describing microstructure and physical properties of bricks. • XRPD derived cell parameter of spinel is proposed as an indicator of firing temperature. • SANS effectively describes brick micro and nanostructure, including closed porosity. • Fractal quality of pore surface is proposed as ‘fingerprint’ of brick manufacturing.

  5. X-ray and neutron techniques for nanomaterials characterization

    CERN Document Server

    2016-01-01

    Fifth volume of a 40 volume series on nanoscience and nanotechnology, edited by the renowned scientist Challa S.S.R. Kumar. This handbook gives a comprehensive overview about X-ray and Neutron Techniques for Nanomaterials Characterization. Modern applications and state-of-the-art techniques are covered and make this volume an essential reading for research scientists in academia and industry.

  6. Two-axis Neutron and X-ray Reflectivity

    DEFF Research Database (Denmark)

    Bouwman, W.G.; Vigild, M.E.; Findeisen, E.

    1997-01-01

    Sample alignment for neutron (and in some cases x-ray) reflectometry can be complicated due to a coupling between angle and position which occurs when slits are used to define the path of the beam. Misalignments in sample position or sample rotation angle give rise to systematic errors in the exp...

  7. Comparative analysis of dose rates in bricks determined by neutron activation analysis, alpha counting and X-ray fluorescence analysis for the thermoluminescence fine grain dating method

    Czech Academy of Sciences Publication Activity Database

    Bártová, H.; Kučera, Jan; Musílek, L.; Trojek, T.

    2014-01-01

    Roč. 104, NOV (2014), s. 393-397 ISSN 0969-806X. [1st International Conference on Dosimetry and its Applications (ICDA). Prague, 23.6.2013-28.6.2013] R&D Projects: GA MŠk(XE) LM2011019 Institutional support: RVO:61389005 Keywords : Alpha coutning * neutron activation analysis * X-ray fluorescence * thermoluminescence dating * dose rate Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 1.380, year: 2014

  8. Diffuse scattering of neutrons and X-rays

    International Nuclear Information System (INIS)

    Novion, C.H. de

    1978-01-01

    Diffuse scattering is used to study defect concentrations of about 10 -4 in the case of X-rays and 10 -3 in the case of neutrons. The foundations of diffuse scattering formalism are given, some experimental devices described and a few applications discussed: study by diffraction on powders of defects in CeOsub(2-x); short-range order study by X-rays on Cusub(0.75) Ausub(0.25); short-range order study by neutrons on Cusub(0.435)Nisub(0.565); short-range order study by electrons TiOx; study of irradiation-induced self-interstitials in Al; study of holes created by neutrons in Al [fr

  9. X-ray spectrum local method

    International Nuclear Information System (INIS)

    Avdonin, S.A.

    1985-01-01

    General characteristic and bases of X-ray spectrum local method used for qualitative and quantitative analyses of the mineral chemical composition with volumetric locality of several cubic micrometers. The method is based on the excitation in a sample of characteristic and bremsstrahlung spectra by means of a narrow electron beam at 5-50 keV accelerating voltage. Application of the method when studying uranium minerals and ores is considered. The method allows to determine the uranium presence forms in the ores, morphological features of the minerals, mineral microstructure, UO 2 and UO 3 ratios for unhydrous uraninites and pitchblendes and also to determine mineralization age

  10. X-ray and neutron diffraction studies of crystallinity in hydroxyapatite coatings.

    Science.gov (United States)

    Girardin, E; Millet, P; Lodini, A

    2000-02-01

    To standardize industrial implant production and make comparisons between different experimental results, we have to be able to quantify the crystallinity of hydroxyapatite. Methods of measuring crystallinity ratio were developed for various HA samples before and after plasma spraying. The first series of methods uses X-ray diffraction. The advantage of these methods is that X-ray diffraction equipment is used widely in science and industry. In the second series, a neutron diffraction method is developed and the results recorded are similar to those obtained by the modified X-ray diffraction methods. The advantage of neutron diffraction is the ability to obtain measurements deep inside a component. It is a nondestructive method, owing to the very low absorption of neutrons in most materials. Copyright 2000 John Wiley & Sons, Inc.

  11. On hard X-ray spectra of accreting neutron stars

    International Nuclear Information System (INIS)

    Zheleznyakov, V.V.

    1982-01-01

    Formation of the spectra of X-ray pulsars and gamma bursters is investigated. Interpretation of a hard X-ray spectrum of pulsars containing cyclotron lines is feasible on the basis of an isothermal model of a polar spot heated due to acccretion to a neutron star. It has been ascertained that in the regions responsible for the formation of continuum radiation and lines the mode polarization is determined by a magnetized vacuum rather than by a plasma. Bearing this in mind, the influence of the magnetic field of a star on the wide wings of the cyclotron line and on its depth is discussed. The part played by the accreting column in the case of strong accretion (approx. equal to 10 19 el cm -3 ) needed for long sustaining of the high level of X-rays from a neutron star-pulsar is studied. There occur the gaps in spectrum at frequencies close to the electron gyro-frequency and its harmonics due to the screening of the hot spot by the opaque gyro-resonant layer located within the accreting column. These gaps ensure the formation of cyclotron lines in absorption irrespective of the presence of such lines in the X-ray spectrum of a polar hot spot. (orig./WL)

  12. Comparative analysis of dose rates in bricks determined by neutron activation analysis, alpha counting and X-ray fluorescence analysis for the thermoluminescence fine grain dating method

    Science.gov (United States)

    Bártová, H.; Kučera, J.; Musílek, L.; Trojek, T.

    2014-11-01

    In order to evaluate the age from the equivalent dose and to obtain an optimized and efficient procedure for thermoluminescence (TL) dating, it is necessary to obtain the values of both the internal and the external dose rates from dated samples and from their environment. The measurements described and compared in this paper refer to bricks from historic buildings and a fine-grain dating method. The external doses are therefore negligible, if the samples are taken from a sufficient depth in the wall. However, both the alpha dose rate and the beta and gamma dose rates must be taken into account in the internal dose. The internal dose rate to fine-grain samples is caused by the concentrations of natural radionuclides 238U, 235U, 232Th and members of their decay chains, and by 40K concentrations. Various methods can be used for determining trace concentrations of these natural radionuclides and their contributions to the dose rate. The dose rate fraction from 238U and 232Th can be calculated, e.g., from the alpha count rate, or from the concentrations of 238U and 232Th, measured by neutron activation analysis (NAA). The dose rate fraction from 40K can be calculated from the concentration of potassium measured, e.g., by X-ray fluorescence analysis (XRF) or by NAA. Alpha counting and XRF are relatively simple and are accessible for an ordinary laboratory. NAA can be considered as a more accurate method, but it is more demanding regarding time and costs, since it needs a nuclear reactor as a neutron source. A comparison of these methods allows us to decide whether the time- and cost-saving simpler techniques introduce uncertainty that is still acceptable.

  13. High-level expression and deuteration of sperm whale myoglobin: A study of its solvent structure by X-ray and neutron diffraction methods

    Energy Technology Data Exchange (ETDEWEB)

    Shu, F. [State Univ. of New York, Stony Brook, NY (United States); Ramakrishnan, V. [Brookhaven National Laboratory, Upton, NY (United States); Schoenborn, B.P. [Los Alamos National Laboratory, NM (United States)

    1994-12-31

    Neutron diffraction has become one of the best ways to study light atoms, such as hydrogens. Hydrogen however has a negative coherent scattering factor, and a large incoherent scattering factor, while deuterium has virtually no incoherent scattering, but a large positive coherent scattering factor. Beside causing high background due to its incoherent scattering, the negative coherent scattering of hydrogen tends to cancel out the positive contribution from other atoms in a neutron density map. Therefore a fully deuterated sample will yield better diffraction data with stronger density in the hydrogen position. On this basis, a sperm whale myoglobin gene modified to include part of the A cII protein gene has been cloned into the T7 expression system. Milligram amounts of fully deuterated holo-myoglobin have been obtained and used for crystallization. The synthetic sperm whale myoglobin crystallized in P2{sub 1} space group isomorphous with the native protein crystal. A complete X-ray diffraction dataset at 1.5{Angstrom} has been collected. This X-ray dataset, and a neutron data set collected previously on a protonated carbon-monoxymyoglobin crystal have been used for solvent structure studies. Both X-ray and neutron data have shown that there are ordered hydration layers around the protein surface. Solvent shell analysis on the neutron data further has shown that the first hydration layer behaves differently around polar and apolar regions of the protein surface. Finally, the structure of per-deuterated myoglobin has been refined using all reflections to a R factor of 17%.

  14. High-level expression and deuteration of sperm whale myoglobin: A study of its solvent structure by X-ray and neutron diffraction methods

    International Nuclear Information System (INIS)

    Shu, F.; Ramakrishnan, V.; Schoenborn, B.P.

    1994-01-01

    Neutron diffraction has become one of the best ways to study light atoms, such as hydrogens. Hydrogen however has a negative coherent scattering factor, and a large incoherent scattering factor, while deuterium has virtually no incoherent scattering, but a large positive coherent scattering factor. Beside causing high background due to its incoherent scattering, the negative coherent scattering of hydrogen tends to cancel out the positive contribution from other atoms in a neutron density map. Therefore a fully deuterated sample will yield better diffraction data with stronger density in the hydrogen position. On this basis, a sperm whale myoglobin gene modified to include part of the A cII protein gene has been cloned into the T7 expression system. Milligram amounts of fully deuterated holo-myoglobin have been obtained and used for crystallization. The synthetic sperm whale myoglobin crystallized in P2 1 space group isomorphous with the native protein crystal. A complete X-ray diffraction dataset at 1.5 Angstrom has been collected. This X-ray dataset, and a neutron data set collected previously on a protonated carbon-monoxymyoglobin crystal have been used for solvent structure studies. Both X-ray and neutron data have shown that there are ordered hydration layers around the protein surface. Solvent shell analysis on the neutron data further has shown that the first hydration layer behaves differently around polar and apolar regions of the protein surface. Finally, the structure of per-deuterated myoglobin has been refined using all reflections to a R factor of 17%

  15. Coherent methods in X-ray scattering

    International Nuclear Information System (INIS)

    Gorobtsov, Oleg

    2017-05-01

    X-ray radiation has been used to study structural properties of materials for more than a hundred years. Construction of extremely coherent and bright X-ray radiation sources such as free electron lasers (FELs) and latest generationstorage rings led to rapid development of experimental methods relying on high radiation coherence. These methods allow to perform revolutionary studies in a wide range of fields from solid state physics to biology. In this thesis I focus on several important problems connected with the coherent methods. The first part considers applications of dynamical diffraction theory on crystals to studies with coherent X-ray radiation. It presents the design of a high-resolution spectrometer for free electron lasers that should allow to resolve spectral structure of individual FEL pulses. The spectrometer is based on the principle of dynamical diffraction focusing. The knowledge of individual FEL pulse spectra is necessary for understanding FEL longitudinal coherence. In the same part I present quasi-kinematical approximation to dynamical theory which allows to treat analytically phase effects observed in X-ray coherent imaging on nanocrystals. These effects may play a big role when methods such as ptychography are used to study crystalline samples. The second part deals with measurements of FEL coherence properties using intensity - intensity interferometry. Results of several experiments performed at FELs FLASH and LCLS are revealed in this section. I have developed models and theories to explain the behavior observed in experiments on FLASH. These models allowed to extract information about external positional jitter of FEL pulses and secondary beams present in FEL radiation. In the LCLS experiment the Hanbury Brown and Twiss type interferometry was performed on Bragg peaks from colloidal crystal. This did not require additional measurements without the sample and information was extracted directly from diffraction patterns. Therefore intensity

  16. Coherent methods in X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Gorobtsov, Oleg

    2017-05-15

    X-ray radiation has been used to study structural properties of materials for more than a hundred years. Construction of extremely coherent and bright X-ray radiation sources such as free electron lasers (FELs) and latest generationstorage rings led to rapid development of experimental methods relying on high radiation coherence. These methods allow to perform revolutionary studies in a wide range of fields from solid state physics to biology. In this thesis I focus on several important problems connected with the coherent methods. The first part considers applications of dynamical diffraction theory on crystals to studies with coherent X-ray radiation. It presents the design of a high-resolution spectrometer for free electron lasers that should allow to resolve spectral structure of individual FEL pulses. The spectrometer is based on the principle of dynamical diffraction focusing. The knowledge of individual FEL pulse spectra is necessary for understanding FEL longitudinal coherence. In the same part I present quasi-kinematical approximation to dynamical theory which allows to treat analytically phase effects observed in X-ray coherent imaging on nanocrystals. These effects may play a big role when methods such as ptychography are used to study crystalline samples. The second part deals with measurements of FEL coherence properties using intensity - intensity interferometry. Results of several experiments performed at FELs FLASH and LCLS are revealed in this section. I have developed models and theories to explain the behavior observed in experiments on FLASH. These models allowed to extract information about external positional jitter of FEL pulses and secondary beams present in FEL radiation. In the LCLS experiment the Hanbury Brown and Twiss type interferometry was performed on Bragg peaks from colloidal crystal. This did not require additional measurements without the sample and information was extracted directly from diffraction patterns. Therefore intensity

  17. Micro-array collimators for X-rays and neutrons

    International Nuclear Information System (INIS)

    Cimmino, A.; Allman, B.E.; Klein, A.G.; Bastie, P.

    1998-08-01

    The authors describe the fabrication techniques of novel, compact optical elements for collimating and/or focusing beams of X-rays or thermal neutrons. These optical elements are solid composite arrays consisting of regular stacks of alternating micro-foils, analogous in action to Soller slit collimators, but up to three orders of magnitude smaller. The arrays are made of alternating metals with suitable refractive indices for reflection and/or absorption of the specific radiation. In one implementation, the arrays are made of stacked micro-foils of transmissive elements (Al, Cu) coated and/or electroplated with absorbing elements (Gd, Cd), which are repeatedly rolled or drawn and restacked to achieve the required collimation parameters. The authors present results of these collimators using both X-rays and neutrons. The performance of the collimating element is limited only by the choice of micro-foil materials and the uniformity of their interfaces

  18. Chemical crystallography with pulsed neutrons and synchrotron x-rays

    International Nuclear Information System (INIS)

    Carrondo, M.A.; Jeffrey, G.A.

    1988-01-01

    Solid-state chemists and physicists, crystallographers and molecular biologists who are using or who plan to use the special properties of pulsed neutron spallation and synchrotron X-ray sources will find this book invaluable. Those scientists who have not yet gained experience in working with such sources will find the basic physics of the radiations, their production and their scattering properties explained, together with descriptions of the different types of diffraction experiments which use them

  19. Combined X-ray and neutron fibre diffraction studies of biological and synthetic polymers

    International Nuclear Information System (INIS)

    Parrot, I.M.; Urban, V.; Gardner, K.H.; Forsyth, V.T.

    2005-01-01

    The fibrous state is a natural one for polymer molecules which tend to assume regular helical conformations rather than the globular structures characteristic of many proteins. Fibre diffraction therefore has broad application to the study of a wide range of biological and synthetic polymers. The purpose of this paper is to illustrate the general scope of the method and in particular to demonstrate the impact of a combined approach involving both X-ray and neutron diffraction methods. While the flux of modern X-ray synchrotron radiation sources allows high quality datasets to be recorded with good resolution within a very short space of time, neutron studies can provide unique information through the ability to locate hydrogen or deuterium atoms that are often difficult or impossible to locate using X-ray methods. Furthermore, neutron fibre diffraction methods can, through the ability to selectively label specific parts of a structure, be used to highlight novel aspects of polymer structure that can not be studied using X-rays. Two examples are given. The first describes X-ray and neutron diffraction studies of conformational transitions in DNA. The second describes structural studies of the synthetic high-performance polymer poly(p-phenylene terephthalamide) (PPTA), known commercially as Kevlar[reg] or Twaron[reg

  20. Combined X-ray and neutron fibre diffraction studies of biological and synthetic polymers.

    Energy Technology Data Exchange (ETDEWEB)

    Parrot, I. M. [Institut Laue-Langevin (ILL); Urban, Volker S [ORNL; Gardner, K. H. [DuPont Experimental Station; Forsyth, V. T. [Institut Laue Langevin and Keele University

    2005-04-01

    The fibrous state is a natural one for polymer molecules which tend to assume regular helical conformations rather than the globular structures characteristic of many proteins. Fibre diffraction therefore has broad application to the study of a wide range of biological and synthetic polymers. The purpose of this paper is to illustrate the general scope of the method and in particular to demonstrate the impact of a combined approach involving both X-ray and neutron diffraction methods. While the flux of modern X-ray synchrotron radiation sources allows high quality datasets to be recorded with good resolution within a very short space of time, neutron studies can provide unique information through the ability to locate hydrogen or deuterium atoms that are often difficult or impossible to locate using X-ray methods. Furthermore, neutron fibre diffraction methods can, through the ability to selectively label specific parts of a structure, be used to highlight novel aspects of polymer structure that can not be studied using X-rays. Two examples are given. The first describes X-ray and neutron diffraction studies of conformational transitions in DNA. The second describes structural studies of the synthetic high-performance polymer poly(p-phenylene terephthalamide) (PPTA), known commercially as Kevlar{reg_sign} or Twaron{reg_sign}.

  1. Combined X-ray and neutron fibre diffraction studies of biological and synthetic polymers

    Science.gov (United States)

    Parrot, I. M.; Urban, V.; Gardner, K. H.; Forsyth, V. T.

    2005-08-01

    The fibrous state is a natural one for polymer molecules which tend to assume regular helical conformations rather than the globular structures characteristic of many proteins. Fibre diffraction therefore has broad application to the study of a wide range of biological and synthetic polymers. The purpose of this paper is to illustrate the general scope of the method and in particular to demonstrate the impact of a combined approach involving both X-ray and neutron diffraction methods. While the flux of modern X-ray synchrotron radiation sources allows high quality datasets to be recorded with good resolution within a very short space of time, neutron studies can provide unique information through the ability to locate hydrogen or deuterium atoms that are often difficult or impossible to locate using X-ray methods. Furthermore, neutron fibre diffraction methods can, through the ability to selectively label specific parts of a structure, be used to highlight novel aspects of polymer structure that can not be studied using X-rays. Two examples are given. The first describes X-ray and neutron diffraction studies of conformational transitions in DNA. The second describes structural studies of the synthetic high-performance polymer poly(p-phenylene terephthalamide) (PPTA), known commercially as Kevlar® or Twaron®.

  2. Combined X-ray and neutron fibre diffraction studies of biological and synthetic polymers

    Energy Technology Data Exchange (ETDEWEB)

    Parrot, I.M. [Institut Laue Langevin, 6 Rue Jules Horowitz, 38042 Grenoble Cedex 9 (France); Institute of Science and Technology in Medicine, Keele University Medical School, Staffordshire ST4 7QB (United Kingdom); Urban, V. [Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831-6100 (United States); Gardner, K.H. [Department of Materials Science and Engineering University of Delaware, Newark, DE 19719 (United States); Forsyth, V.T. [Institut Laue Langevin, 6 Rue Jules Horowitz, 38042 Grenoble Cedex 9 (France) and Institute of Science and Technology in Medicine, Keele University Medical School, Staffordshire ST4 7QB (United Kingdom)]. E-mail: tforsyth@ill.fr

    2005-08-15

    The fibrous state is a natural one for polymer molecules which tend to assume regular helical conformations rather than the globular structures characteristic of many proteins. Fibre diffraction therefore has broad application to the study of a wide range of biological and synthetic polymers. The purpose of this paper is to illustrate the general scope of the method and in particular to demonstrate the impact of a combined approach involving both X-ray and neutron diffraction methods. While the flux of modern X-ray synchrotron radiation sources allows high quality datasets to be recorded with good resolution within a very short space of time, neutron studies can provide unique information through the ability to locate hydrogen or deuterium atoms that are often difficult or impossible to locate using X-ray methods. Furthermore, neutron fibre diffraction methods can, through the ability to selectively label specific parts of a structure, be used to highlight novel aspects of polymer structure that can not be studied using X-rays. Two examples are given. The first describes X-ray and neutron diffraction studies of conformational transitions in DNA. The second describes structural studies of the synthetic high-performance polymer poly(p-phenylene terephthalamide) (PPTA), known commercially as Kevlar[reg] or Twaron[reg].

  3. Neutron and X-ray facilities in new Purnima extension building

    International Nuclear Information System (INIS)

    Sarkar, P.S.; Patel, Tarun; Gadkari, S.C.

    2017-01-01

    Neutron and X-ray Physics Section of Technical Physics Division has laboratories involving X-ray, gamma ray and neutrons in the New Purnima Extension Building (NPEB), behind Purnima Laboratories, BARC. Research activities related to X-ray, Gamma and neutron based detection and imaging for societal, departmental and security applications are being carried out in these laboratories

  4. Micronucleus formation compared to the survival rate of human melanoma cells after X-ray and neutron irradiation and hyperthermia

    Energy Technology Data Exchange (ETDEWEB)

    van Beuningen, D.; Streffer, C.; Bertholdt, G.

    1981-09-01

    After neutron and X-ray irradiation and combined X-ray irradiation and hyperthermia (3 hours, 42/sup 0/C), the survival rate of human melanoma cells was measured by means of the colony formation test and compared to the formation of micronuclei. Neutrons had a stronger effect on the formation of micronuclei than the combination of X-rays and hyperthermia. X-rays had the lowest effect. The dose effect curve showed a break at that dose level at which a reduction of cells was observed in the cultures. A good relation between survival rate and formation of micronuclei was found for the X-ray irradiation, but not for the neutron irradiation and the combined treatment. These observations are discussed. At least for X-rays, the micronucleus test has turned out to be a good screening method for the radiosensitivity of a biologic system.

  5. Resolution of crystal structures by X-ray and neutrons powder diffraction using global optimisation methods; Resolution des structures cristallines par diffraction des rayons X et neutrons sur poudres en utilisant les methodes d'optimisation globale

    Energy Technology Data Exchange (ETDEWEB)

    Palin, L

    2005-03-15

    We have shown in this work that X-ray diffraction on powder is a powerful tool to analyze crystal structure. The purpose of this thesis is the resolution of crystal structures by X-ray and neutrons diffraction on powder using global optimisation methods. We have studied 3 different topics. The first one is the order-disorder phenomena observed in some globular organic molecular solids. The second is the opiate family of neuropeptides. These neurotransmitters regulate sensory functions including pain and control of respiration in the central nervous system. The aim of our study was to try to determine the crystal structure of Leu-enkephalin and some of its sub-fragments. The determination of the crystal structures has been done performing Monte Carlo simulations. The third one is the location of benzene in a sodium-X zeolite. The zeolite framework was already known and the benzene has been localized by simulated annealing and by the use of maximum entropy maps.

  6. Black hole and neutron star soft X-ray transients: a hard X-ray view of their outbursts

    International Nuclear Information System (INIS)

    Yu, W.

    2004-01-01

    The RXTE public observations of the outbursts of black hole soft X-ray transients XTE J1550-564, XTE J1859+226, 4U 1630-47, XTE J1118+480, XTE J1650-500, and the neutron star soft X-ray transients 4U 1608-52, Aquila X-1, including a variable 'persistent' neutron star low mass X-ray binary 4U 1705-44, are summarized in this paper. The hard X-ray view of those outbursts, which is quite different from that of the soft X-ray band, suggests that there are several types of outbursts which result in different hard X-ray outburst profile - the outburst profiles are energy dependent. One type is the low/hard state outbursts, the other type is the outburst showing transitions from the low/hard state to the high/soft state, or to the intermediate or to the very high state. The later has an initial low/hard state, introducing the phenomena that the hard X-ray precedes the soft X-ray in the outburst rise. Such outbursts in XTE J1550-564, Aql X-1 and 4U 1705-44 support a two-accretion-flow model which involves one Keplerian disk flow and one sub-Keplerian flow for the initial outburst rise

  7. Neutron and X-ray diffraction from modulated structures

    International Nuclear Information System (INIS)

    Harris, P.

    1994-07-01

    This thesis describes X-ray and neutron scattering experiments performed on two examples of modulated structures. After an introduction to the subject of modulated structures, the thesis is divided in three parts. A single crystal elastic neutron scattering experiment between 4.2 and 115 Κ has been performed and four-circle X-ray data have been collected at 8 Κ for the monoclinic low-temperature phase of the layered perovskite PAMC. The results from the neutron scattering experiment indicate that magnetoelastic effects influence the ordering of the crystal. The X-ray experiments have made it possible to determine the crystal structure in the low-temperature phase. The superspace group is P2 1 /b(β-30)Os, with β = 1/3. A small-angle neutron scattering experiment has been performed on the magnetic structure of manganese silicide. When a magnetic field is applied, the modulation vectors turn towards the field direction, showing domain growth and diverging peak widths as they approach the field direction. Phase 'A' is established to have the modulation vectors directed perpendicular to the field direction. Cooling in zero field shows increasing peak widths at low temperatures, indicating a lock-in transition below the lowest reached temperature. To be able to analyse the data of the magnetic order in MnSi, and analytical calculation of the three dimensional resolution function for a small-angle neutron scattering spectrometer has been performed. The calculation is done by application of a combination of phase space analysis and Gaussian approximations for the neutron distribution as well as for the transmission functions of the different apertures. A finite mosaic spread of the crystal and finite correlation widths of the Bragg reflections have been included in the cross section. (au) (3 tabs., 48 ills., 100 refs.)

  8. Analysis of the inclination method for investigating the pendelloesung interferences of neutron beams and X-rays

    International Nuclear Information System (INIS)

    Belova, N.E.; Somenkov, V.A.; Utemisov, K.; Shilshtein, S.Sh.

    1983-01-01

    Pendelloesung interferences in a wide range of crystal thicknesses and extinction lengths can be measured by the inclination method. The positions of the extrema of intensity coincide well with the calculated ones but the observed contrast of the oscillations is considerably weaker than the theoretical one. A mathematical model is given, taking into account the influence of several factors which characterize the incident radiation as well as the crystal examined. From this follows, that the inclination method is insensitive to many disturbing factors, and therefore it can be used for metrological purposes. (author)

  9. X-ray and Neutron Diffraction in the Study of Organic Crystalline Hydrates

    Directory of Open Access Journals (Sweden)

    Katharina Fucke

    2010-07-01

    Full Text Available A review. Diffraction methods are a powerful tool to investigate the crystal structure of organic compounds in general and their hydrates in particular. The laboratory standard technique of single crystal X-ray diffraction gives information about the molecular conformation, packing and hydrogen bonding in the crystal structure, while powder X-ray diffraction on bulk material can trace hydration/dehydration processes and phase transitions under non-ambient conditions. Neutron diffraction is a valuable complementary technique to X-ray diffraction and gives highly accurate hydrogen atom positions due to the interaction of the radiation with the atomic nuclei. Although not yet often applied to organic hydrates, neutron single crystal and neutron powder diffraction give precise structural data on hydrogen bonding networks which will help explain why hydrates form in the first place.

  10. Advances in martensitic transformations in Cu-based shape memory alloys achieved by in situ neutron and synchrotron X-ray diffraction methods

    Czech Academy of Sciences Publication Activity Database

    Malard, B.; Šittner, Petr; Berveiller, S.; Patoor, E.

    2012-01-01

    Roč. 13, č. 3 (2012), s. 280-292 ISSN 1631-0705 R&D Projects: GA ČR GAP108/10/1296; GA ČR GAP107/12/0800 EU Projects: European Commission(XE) 262806 - SmartNets Institutional research plan: CEZ:AV0Z10100520 Keywords : stress induced martensitic transformation * Cu-based shape memory alloys * neutron diffraction * X-ray * synchrotron * in situ * multiscale analysis Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.818, year: 2012

  11. X-ray fluorescence method for trace analysis and imaging

    International Nuclear Information System (INIS)

    Hayakawa, Shinjiro

    2000-01-01

    X-ray fluorescence analysis has a long history as conventional bulk elemental analysis with medium sensitivity. However, with the use of synchrotron radiation x-ray fluorescence method has become a unique analytical technique which can provide tace elemental information with the spatial resolution. To obtain quantitative information of trace elemental distribution by using the x-ray fluorescence method, theoretical description of x-ray fluorescence yield is described. Moreover, methods and instruments for trace characterization with a scanning x-ray microprobe are described. (author)

  12. Neutron and x-ray scattering studies of premartensitic phenomena

    International Nuclear Information System (INIS)

    Shapiro, S.M.

    1987-01-01

    This paper discusses neutron and x-ray investigations of some metallic alloys which are known to exhibit martensitic transformations. It is shown that precursor effects are usually present in the diffuse scattering and in the phonon dispersion curves, but the transition cannot be described in terms of the soft mode picture used in the Landau and Devonshire theory to describe structural phase transitions. In addition, it is noted that it is inappropriate to look at these microstructures as incommensurate systems, but more correctly as a coherent coexistence of two phases

  13. From x-ray telescopes to neutron scattering: Using axisymmetric mirrors to focus a neutron beam

    International Nuclear Information System (INIS)

    Khaykovich, B.; Gubarev, M.V.; Bagdasarova, Y.; Ramsey, B.D.; Moncton, D.E.

    2011-01-01

    We demonstrate neutron beam focusing by axisymmetric mirror systems based on a pair of mirrors consisting of a confocal ellipsoid and hyperboloid. Such a system, known as a Wolter mirror configuration, is commonly used in X-ray telescopes. The axisymmetric Wolter geometry allows nesting of several mirror pairs to increase collection efficiency. We implemented a system containing four nested Ni mirror pairs, which was tested by the focusing of a polychromatic neutron beam at the MIT Reactor. In addition, we have carried out extensive ray-tracing simulations of the mirrors and their performance in different situations. The major advantages of the Wolter mirrors are nesting for large angular collection and aberration-free performance. We discuss how these advantages can be utilized to benefit various neutron scattering methods, such as imaging, SANS, and time-of-flight spectroscopy.

  14. Apparatus and method X-ray image processing

    International Nuclear Information System (INIS)

    1984-01-01

    The invention relates to a method for X-ray image processing. The radiation passed through the object is transformed into an electric image signal from which the logarithmic value is determined and displayed by a display device. Its main objective is to provide a method and apparatus that renders X-ray images or X-ray subtraction images with strong reduction of stray radiation. (Auth.)

  15. Hard state neutron star and black hole X-ray binaries in the radio:X-ray luminosity plane

    Science.gov (United States)

    Gallo, Elena; Degenaar, Nathalie; van den Eijnden, Jakob

    2018-05-01

    Motivated by the large body of literature around the phenomenological properties of accreting black hole (BH) and neutron star (NS) X-ray binaries in the radio:X-ray luminosity plane, we carry out a comparative regression analysis on 36 BHs and 41 NSs in hard X-ray states, with data over 7 dex in X-ray luminosity for both. The BHs follow a radio to X-ray (logarithmic) luminosity relation with slope β = 0.59 ± 0.02, consistent with the NSs' slope (β =0.44^{+0.05}_{-0.04}) within 2.5σ. The best-fitting intercept for the BHs significantly exceeds that for the NSs, cementing BHs as more radio loud, by a factor ˜22. This discrepancy can not be fully accounted for by the mass or bolometric correction gap, nor by the NS boundary layer contribution to the X-rays, and is likely to reflect physical differences in the accretion flow efficiency, or the jet powering mechanism. Once importance sampling is implemented to account for the different luminosity distributions, the slopes of the non-pulsating and pulsating NS subsamples are formally inconsistent (>3σ), unless the transitional millisecond pulsars (whose incoherent radio emission mechanism is not firmly established) are excluded from the analysis. We confirm the lack of a robust partitioning of the BH data set into separate luminosity tracks.

  16. Novel X-ray Communication Based XNAV Augmentation Method Using X-ray Detectors

    Directory of Open Access Journals (Sweden)

    Shibin Song

    2015-09-01

    Full Text Available The further development of X-ray pulsar-based NAVigation (XNAV is hindered by its lack of accuracy, so accuracy improvement has become a critical issue for XNAV. In this paper, an XNAV augmentation method which utilizes both pulsar observation and X-ray ranging observation for navigation filtering is proposed to deal with this issue. As a newly emerged concept, X-ray communication (XCOM shows great potential in space exploration. X-ray ranging, derived from XCOM, could achieve high accuracy in range measurement, which could provide accurate information for XNAV. For the proposed method, the measurement models of pulsar observation and range measurement observation are established, and a Kalman filtering algorithm based on the observations and orbit dynamics is proposed to estimate the position and velocity of a spacecraft. A performance comparison of the proposed method with the traditional pulsar observation method is conducted by numerical experiments. Besides, the parameters that influence the performance of the proposed method, such as the pulsar observation time, the SNR of the ranging signal, etc., are analyzed and evaluated by numerical experiments.

  17. Extinction correction in white X-ray and neutron diffraction

    International Nuclear Information System (INIS)

    Tomiyoshi, S.; Yamada, M.; Watanabe, H.

    1980-01-01

    Extinction effects in white-beam X-ray and neutron diffraction are considered. In white-beam diffraction, a small deviation of the wavelength from the Bragg condition Δlambda is a variable which represents the line profile of the diffraction peaks, so that by using the new parameter Δlambda the theory is converted to one in white-beam diffraction. It is shown that for a convex crystal, primary extinction agrees with the results calculated already for monochromatic diffraction. The same relation is shown to hold in secondary extinction. It is concluded that extinction theory derived for monochromatic diffraction is applicable without any modification in white-beam diffraction. (Auth.)

  18. High-energy X-ray production in a boundary layer of an accreting neutron star

    International Nuclear Information System (INIS)

    Hanawa, Tomoyuki

    1991-01-01

    It is shown by Monte Carlo simulation that high-energy X-rays are produced through Compton scattering in a boundary layer of an accreting neutron star. The following is the mechanism for the high-energy X-ray production. An accreting neutron star has a boundary layer rotating rapidly on the surface. X-rays radiated from the star's surface are scattered in part in the boundary layer. Since the boundary layer rotates at a semirelativistic speed, the scattered X-ray energy is changed by the Compton effect. Some X-rays are scattered repeatedly between the neutron star and the boundary layer and become high-energy X-rays. This mechanism is a photon analog of the second-order Fermi acceleration of cosmic rays. When the boundary layer is semitransparent, high-energy X-rays are produced efficiently. 17 refs

  19. X-Ray analysis and methods for nondestructive control (On the 100-anniversary of X-ray foundation)

    International Nuclear Information System (INIS)

    Sosnin, F.R.

    1995-01-01

    Brief consideration is given to the history of X-ray discovery, formation of domestic X-ray industry. Principles of operation and potentialities of X-ray diffraction analysis, gammagraphy, radioscopy, radiometric analysis are described briefly. Domestic and foreign scientists, institutes and companies who contributed much to development of methods for nondestructive control are listed

  20. Hidden explosives detector employing pulsed neutron and x-ray interrogation

    International Nuclear Information System (INIS)

    Schultz, F.J.; Caldwell, J.T.

    1993-01-01

    Methods and systems for the detection of small amounts of modern, highly-explosive nitrogen-based explosives, such as plastic explosives, hidden in airline baggage. Several techniques are employed either individually or combined in a hybrid system. One technique employed in combination is X-ray imaging. Another technique is interrogation with a pulsed neutron source in a two-phase mode of operation to image both nitrogen and oxygen densities. Another technique employed in combination is neutron interrogation to form a hydrogen density image or three-dimensional map. In addition, deliberately-placed neutron-absorbing materials can be detected

  1. Hidden explosives detector employing pulsed neutron and x-ray interrogation

    Science.gov (United States)

    Schultz, Frederick J.; Caldwell, John T.

    1993-01-01

    Methods and systems for the detection of small amounts of modern, highly-explosive nitrogen-based explosives, such as plastic explosives, hidden in airline baggage. Several techniques are employed either individually or combined in a hybrid system. One technique employed in combination is X-ray imaging. Another technique is interrogation with a pulsed neutron source in a two-phase mode of operation to image both nitrogen and oxygen densities. Another technique employed in combination is neutron interrogation to form a hydrogen density image or three-dimensional map. In addition, deliberately-placed neutron-absorbing materials can be detected.

  2. X-ray and neutron scattering from amorphous diamondlike carbon and hydrocarbon films

    International Nuclear Information System (INIS)

    Findeisen, E.

    1994-10-01

    In this report amorphous, diamondlike, carbon and hydrocarbon films are investigated by two different methods, namely, X-ray scattering and a combination of X-ray and neutron reflectivity. As specular reflectivity probes the scattering length density profile of a sample perpendicular to its surface, the combination of X-ray and neutron reflectivity reveals the nuclei density of both carbon and hydrogen separately. This allows to calculate the concentration of hydrogen in the films, which varies in the presented experiments between 0 and 36 atomic %. This method is a new and nondestructive technique to determine the concentration of hydrogen within an error of about ±1 at. % in samples with sharp interfaces. It is well suited for thin diamondlike carbon films. X-ray scattering is used to obtain structural information on the atomic scale, especially the average carbon-carbon distance and the average coordination number of the carbon atoms. As grazing incidence diffraction experiments were not successful, free-standing films are used for the scattering experiments with synchrotron light. However, the scattered intensity for large scattering vectors is, in spite of the intense primary beam, very weak, and therefore the accuracy of the obtained structural parameter is not sufficient to prove the diamondlike properties also on the atomic scale. (au) (10 tabs., 76 ills., 102 refs.)

  3. Neutron and X-ray emission studies in a low energy plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Zakaullah, M. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics; Murtaza, G. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics; Qamar, S. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics; Ahmad, I. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics; Beg, M.M. [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Physics

    1996-03-01

    In a low energy Mather-type plasma focus energized by a single 32 {mu}F capacitor, the X-ray and neutron emission is investigated using time-integrated and time-resolved detectors. The X-ray emission profile has a width (FWHM) of 40-50 ns. The neutron emission profile is broader compared to the X-ray emission profile and also delayed by 30-40 ns. To identify different regimes of X-ray emission, an X-ray pin-hole camera along with different absorption filters is employed. While the X-ray emission is high within a narrow pressure range of 2.0-2.5 mbar, the neutron emission is intense for a wider range of 1.0-4.5 mbar. The intense X-ray emission seems to originate from the axially moving shock wave. These results also indicate rather different production mechanisms for X-ray and neutron emission. Also on comparing the X-ray images with Al(2 {mu}m), Al(5 {mu}m), Al(9 {mu}m) filters, we find that the bulk of X-rays from the focus filament have energies less than 2 keV. (orig.).

  4. Mortality and sterility induced in Piophila casei by x-ray and neutron irradiation

    International Nuclear Information System (INIS)

    Sacchi, L.; Gasperi, G.; Grigolo, A.; Caprotti, M.; Pinelli, T.; Altieri, S.

    1977-01-01

    Different doses of neutrons and X-rays were given to 5-day-old pupae of Piophila casei L. (Diptera, Piophilidae), just before their emergence. The mortality and sterility induced by the different types of radiation were measured. Neutrons are more effective than X-rays in provoking lethal lesions in somatic cells. Females are more resistant than males to the sterilizing action of neutrons, the relative biological efficiency of neutrons being 6 and 3.5, respectively

  5. Mortality and sterility induced in Piophila casei by x-ray and neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Sacchi, L; Gasperi, G [Pavia Univ. (Italy). Ist. di Zoologia; Grigolo, A [Bari Univ. (Italy). Ist. di Zoologia e Anatomia Comparata; Caprotti, M [Pavia Univ. (Italy). Fondazio Clinica del Lavoro. Reparto di Radiologia; Pinelli, T; Altieri, S [Pavia Univ. (Italy). Istituto di Fisica Nucleare

    1977-01-01

    Different doses of neutrons and X-rays were given to 5-day-old pupae of Piophila casei L. (Diptera, Piophilidae), just before their emergence. The mortality and sterility induced by the different types of radiation were measured. Neutrons are more effective than X-rays in provoking lethal lesions in somatic cells. Females are more resistant than males to the sterilizing action of neutrons, the relative biological efficiency of neutrons being 6 and 3.5, respectively.

  6. Comparison of two semi-absolute methods. k{sub 0}-instrumental neutron activation analysis and fundamental parameter method X-ray fluorescence spectrometry for Ni-based alloys

    Energy Technology Data Exchange (ETDEWEB)

    Wasim, Mohammad [Pakistan Institute of Nuclear Science and Technology, Islamabad (Pakistan). Chemistry Div.; Ahmad, Sajjad [Quaid-i-Azam Univ., Islamabad (Pakistan). Dept. of Chemistry

    2015-07-01

    Nickel based alloys play important role in nuclear, mechanical and chemical industry. Two semi-absolute standardless methods, k{sub 0}-instrumental neutron activation analysis (k{sub 0}-INAA) and fundamental parameter X-ray fluorescence spectrometry (FP-XRF) were used for the characterization of certified nickel based alloys. The optimized experimental conditions for NAA provided results for 18 and XRF for 15 elements. Both techniques were unable to quantify some important alloy making elements. However, both reported results of other elements as information values. The techniques were analyzed for their sensitivity and accuracy. Sensitivity was evaluated by the number of elements determined by each technique. Accuracy was ascertained by using the linear regression analysis and the average root mean squared error.

  7. X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

    International Nuclear Information System (INIS)

    Wharton, C. J.; Seabury, E. H.; Chichester, D. L.; Caffrey, A. J.; Simpson, J.; Lemchak, M.

    2011-01-01

    Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

  8. PREFACE: Buried Interface Sciences with X-rays and Neutrons 2010

    Science.gov (United States)

    Sakurai, Kenji

    2011-09-01

    generation synchrotron radiation is highly reliable in practice, as well as being quantitative and reproducible. The use of neutron analysis complements x-ray experiments, and helps to enhance information such as contrasts in soft materials and magnetic structures, which are not always given clearly by x-rays. The techniques ensure non-contact, non-destructive measurement, and one can also use the same specimen for further analysis by other methods. On the other hand, we are now aware that it not always straightforward to solve many realistic problems related to buried interfaces. Although advanced synchrotron x-rays and neutrons are highly useful, we still note many limitations. Collaboration with theoreticians is one of the most important directions in which to improve analysis. Over the past couple of years, scientists have argued over the existence of a depletion layer between oil and water. The argument is far from settled, even though highly sophisticated x-ray reflectometry seems to have given quite strong experimental evidence. In most cases, analysis of x-ray reflectivity depends on the model. This is good provided that one can be sure of the validity of the model, as in the case of multilayered thin films in industrial devices. However, sometimes our main interest lies in the model itself. Therefore, we should insist on introducing something new to justify the model scientifically, instead of just claiming that x-ray data can be explained by a certain model. Probably collaboration with theoretical research could be helpful. Another important direction would be to develop a method of model-free analysis. During this workshop, participants talked about the present status of their own work. The workshop was open to those who are not particular specialists in x-ray and neutron experiments, but discussions were detailed and thorough. We discussed how buried interface research by x-ray and neutron experiments can be strengthened in the future. One of the most important

  9. The application of X-ray, γ-ray and neutron diffraction to the characterization of single crystal perfection

    International Nuclear Information System (INIS)

    Freund, A.; Schneider, J.R.

    1976-01-01

    The work is divided into the following three chapters: 1) diffraction by perfect and imperfect crystals, 2) experimental apparatus (describing gamma ray, X-ray and neutron diffractometers), 3) application of diffraction methods to the development of neutron monochromators. (WBU) [de

  10. Oscillations During Thermonuclear X-ray Bursts: A New Probe of Neutron Stars

    Science.gov (United States)

    Strohmayer, Tod E.; White, Nicholas E. (Technical Monitor)

    2002-01-01

    Observations of thermonuclear (also called Type 1) X-ray bursts from neutron stars in low mass X-ray binaries (LMXB) with the Rossi X-ray Timing Explorer (RXTE) have revealed large amplitude, high coherence X-ray brightness oscillations with frequencies in the 300 - 600 Hz range. Substantial spectral and timing evidence point to rotational modulation of the X-ray burst flux as the cause of these oscillations, and it is likely that they reveal the spin frequencies of neutron stars in LMXB from which they are detected. Here we review the status of our knowledge of these oscillations and describe how they can be used to constrain the masses and radii of neutron stars as well as the physics of thermonuclear burning on accreting neutron stars.

  11. Fast neutron activation analysis and radioisotope X-ray fluorescence study on KALEWA and NAMMA coal

    International Nuclear Information System (INIS)

    Naing-Win

    1981-07-01

    Kalewa coal was studied with Fast Neutron Activation Analysis (FNAA) technique, employing KAMAN A-710 neutron generator and HP(Ge) detector coupled to ''Canberra'' series 30 MCA. Sequential irradiation and dual aluminium foil monitoring method was employed. Simultaneous multielement analysis was carried out. Namma Coal was studied with radioisotope X-ray Fluorescence (XRF) technique, employing Co-57 exciter source and HP(Ge) detector coupled to ''Canberra'' series 40 MCA. In both FNAA and XRF study, the results obtained were compared to that obtained with Atomic Absorption Spectrophotometry (AAS) technique. Finally, the results were reviewed together with those obtained from similar work on coal with FNAA and XRF techniques. (author)

  12. Fast neutron activation analysis and radioisotope X-ray fluorescence study on KALEWA and NAMMA coal

    Energy Technology Data Exchange (ETDEWEB)

    Naing-Win, [Arts and Science University, Yangon (Myanmar)

    1981-07-01

    Kalewa coal was studied with Fast Neutron Activation Analysis (FNAA) technique, employing KAMAN A-710 neutron generator and HP(Ge) detector coupled to ``Canberra`` series 30 MCA. Sequential irradiation and dual aluminium foil monitoring method was employed. Simultaneous multielement analysis was carried out. Namma Coal was studied with radioisotope X-ray Fluorescence (XRF) technique, employing Co-57 exciter source and HP(Ge) detector coupled to ``Canberra`` series 40 MCA. In both FNAA and XRF study, the results obtained were compared to that obtained with Atomic Absorption Spectrophotometry (AAS) technique. Finally, the results were reviewed together with those obtained from similar work on coal with FNAA and XRF techniques. (author).

  13. Simulating the X-ray luminosity of Be X-ray binaries: the case for black holes versus neutron stars

    Science.gov (United States)

    Brown, R. O.; Ho, W. C. G.; Coe, M. J.; Okazaki, A. T.

    2018-04-01

    There are over 100 Be stars that are known to have neutron star companions but only one such system with a black hole. Previous theoretical work suggests this is not due to their formation but due to differences in X-ray luminosity. It has also been proposed that the truncation of the Be star's circumstellar disc is dependent on the mass of the compact object. Hence, Be star discs in black hole binaries are smaller. Since accretion onto the compact object from the Be star's disc is what powers the X-ray luminosity, a smaller disc in black hole systems leads to a lower luminosity. In this paper, simulations are performed with a range of eccentricities and compact object mass. The disc's size and density are shown to be dependent on both quantities. Mass capture and, in turn, X-ray luminosity are heavily dependent on the size and density of the disc. Be/black hole binaries are expected to be up to ˜10 times fainter than Be/neutron star binaries when both systems have the same eccentricity and can be 100 times fainter when comparing systems with different eccentricity.

  14. The response of mouse skin to re-irradiation with x-rays or fast neutrons

    International Nuclear Information System (INIS)

    Tsukiyama, Iwao; Egawa, Sunao; Kumazawa, Akiyoshi; Iino, Yuu.

    1986-01-01

    Effects of neutrons and x-rays on mouse skin which had been previously irradiated with x-rays were investigated. Two tattoo marks were placed in the hairless legs of mice at intervals of 15 mm. The legs were exposed to various doses of x-ray and neutrons to determine the relative biological effectiveness (RBE) using the contraction of the skin as an index. The RBE was 0.93 - 1.73. The legs of the mice were preexposed to 25 Gy of x-ray, and exposed 4 months later. The contraction of the skin began earlier than after the first irradiation. RBE was 2.18 - 2.47. This RBE was higher than that in untreated mice. These results suggest that previously irradiated normal tissues are much more sensitive to neutrons than to x-rays. (author)

  15. Joint application of neutron and X-ray scattering for determination of atomic and electronic structures of molecules and crystals

    International Nuclear Information System (INIS)

    Ozerov, R.P.; Tsirel'son, V.G.

    1978-01-01

    The paper deals with the main principles of methods based on the joint neutron and x-ray diffraction studies. The methods allow one to obtain the information on the charge distribution in molecules in detail. Neutron scattering makes it possible to locate very closely the nucleus of atom or, more precisely, the gravity center of the ellipsoid of nuclear thermal oscillations. X-ray diffraction gives the distribution of electronic density at some distance from the shell gravity center. The joint diffraction method holds the promise and importance for solving physical-chemical problems

  16. X-ray and neutron interrogation of air cargo for mobile applications

    Energy Technology Data Exchange (ETDEWEB)

    Van Liew, Seth

    2015-06-01

    A system for scanning break-bulk cargo for mobile applications is presented. This combines a 140 kV multi-view, multi-energy X-ray system with 2.5 MeV neutrons. The system uses dual energy X-ray radiography with neutron radiography. The X-ray and neutron systems were designed to be collocated in a mobile environment. Various materials were interrogated with the intent of distinguishing threat materials such as explosives from similar benign materials. In particular, the identification of threats and bengins with nearly identical effective atomic numbers has been demonstrated.

  17. X-ray and neutron interrogation of air cargo for mobile applications

    International Nuclear Information System (INIS)

    Van Liew, Seth

    2015-01-01

    A system for scanning break-bulk cargo for mobile applications is presented. This combines a 140 kV multi-view, multi-energy X-ray system with 2.5 MeV neutrons. The system uses dual energy X-ray radiography with neutron radiography. The X-ray and neutron systems were designed to be collocated in a mobile environment. Various materials were interrogated with the intent of distinguishing threat materials such as explosives from similar benign materials. In particular, the identification of threats and bengins with nearly identical effective atomic numbers has been demonstrated

  18. X-ray, neutron, and electron scattering. Report of a materials sciences workshop

    International Nuclear Information System (INIS)

    1977-08-01

    The ERDA Workshop on X-ray, Neutron, and Electron Scattering to assess needs and establish priorities for energy-related basic research on materials. The general goals of the Workshop were: (1) to review various energy technologies where x-ray, neutron, and electron scattering techniques might make significant contributions, (2) to identify present and future materials problems in the energy technologies and translate these problems into requirements for basic research by x-ray, neutron, and electron scattering techniques, (3) to recommend research areas utilizing these three scattering techniques that should be supported by the DPR Materials Sciences Program, and (4) to assign priorities to these research areas

  19. Neutron and X-ray Tomography (NeXT) system for simultaneous, dual modality tomography

    Science.gov (United States)

    LaManna, J. M.; Hussey, D. S.; Baltic, E.; Jacobson, D. L.

    2017-11-01

    Dual mode tomography using neutrons and X-rays offers the potential of improved estimation of the composition of a sample from the complementary interaction of the two probes with the sample. We have developed a simultaneous neutron and 90 keV X-ray tomography system that is well suited to the study of porous media systems such as fuel cells, concrete, unconventional reservoir geologies, limestones, and other geological media. We present the characteristic performance of both the neutron and X-ray modalities. We illustrate the use of the simultaneous acquisition through improved phase identification in a concrete core.

  20. A Study on the Neutron Dose Distribution in Case of 10 MV X-rays Radiotherapy

    International Nuclear Information System (INIS)

    Park, Cheol Soo; Shin, Seong Soo; Lim, Cheong Hwan; Jung, Hong Ryang

    2008-01-01

    This study is to measure the radiation dose of neutrons generated by the particle accelerator during X-ray (photon) treatment with a neutron detection method by using CR-39, and to research how the generation of neutrons may incur problems associated with radiation doses for patient treatment when using high energy photons for cancer treatment as a clinical application. The findings are summarized as follows : The results showed that average 0.35 mSv was measured with exposure of 1 Gy photon in case of fast neutron, 0.65 mSv with exposure of 2 Gy photon, 1.82 mSv exposure of 5 Gy, 0.26 mSv with exposure of 1 Gy photon in case of thermal neutron, 0.56 mSv with exposure of 2 Gy photon, and 1.23 mSv with exposure of 5 Gy of photon. By measuring the occurrence of neutron by using Wedge Filter, it has been confirmed that the occurrence of neutrons increased when using Wedge Filter. The results also showed that more neutrons were detected over the existing experiments when using an SRS Cone requiring high doses of radiation. Total 2.85 mSv neutrons were found on the average with exposure of 5 Gy photon in case of fast neutron and 1.37 mSv neutrons were found on the average with exposure of 5 Gy photon in case of thermal neutron. During the general treatment, about 1.6 times more neutrons over 5 Gy photon were found in case of fast neutron and about 1.12 time more neutrons over 5 Gy photon were found in case of thermal neutron.

  1. Method and apparatus for scanning x-ray tomography

    International Nuclear Information System (INIS)

    Albert, R.D.

    1988-01-01

    In a method of producing a tomographic image of a subject that includes the steps of generating X-rays at a moving origin point by directing a charged particle beam to a target surface, deflecting the charged particle beam to travel the origin point through a predetermined raster scan at the surface, detecting variations of X-ray intensity during the course of the raster scan at spaced apart detection points situated at the opposite side of the subject from the origin point, generating a first sequence of data values that is indicative of variations of X-ray intensity at a first of the detection points at successive times during the course of the raster scan and generating at least a second sequence of data values that is indicative of variations of X-ray intensity at a second of the detection points at successive times during the course of the same raster scan, the improvement is described comprising: combining successive individual data values of the first sequence that are generated by X-rays from successive particular locations in the raster scan with at least individual data values of the second sequence that are generated by X-rays from predetermined successive different locations in the same raster scan in order to produce a composite sequence of data values, and producing an image corresponding to at least a portion of the raster scan which depicts variations of the magnitude of successive data values of the composite sequence

  2. Methods of X-ray examination of condylar knee replacement

    International Nuclear Information System (INIS)

    Vavrik, P.

    1988-01-01

    A detailed description is presented of the methodology of X-ray examination of patients with a condylar knee replacement. Preoperative examination includes standard anterio-posterior and lateral projections, axial projection of the patella in 30 deg flexion of the knee, examination of the mechanical axis of the extremity on a 90 x 30 format and the radioscopic assessment of the centre of the hip joint, essential for the correct centering of the knee implant. Immediately after surgery the position of the implant is checked in two standard projections. Another X-ray check is made after six weeks, before partial loading of the joint is permitted. A complete X-ray examination is made prior to the full loading of the knee joint. The methods are also discussed of the X-ray evaluation of complications such as aseptic loosening of the components, infection, instability, fractures. The general solution od these problems is described. The necessity is underlined of the deliberate and qualified indication of X-ray examinations. The basic prerequisites are listed for reducing the present considerable radiation burden of these patients in the course of the many X-ray examinations. (author). 7 figs., 3 tab., 6 refs

  3. X-Ray and Neutron Scattering Study of the Magnetic Structure of Neodymium Metal

    DEFF Research Database (Denmark)

    Lebech, Bente; Als-Nielsen, Jens Aage; McEwen, K. A.

    1979-01-01

    A combined x-ray and neutron diffraction study has shown that the so-called "triple-q⃗" structure is not the correct model of the magnetic structure of neodymium. The x-ray data showed only the Bragg reflections originating from the double-hcp lattice. Hence, all additional reflections observed...

  4. Application of high resolution x-ray spectrometry preceded by neutron activation for elemental analysis of soil samples

    International Nuclear Information System (INIS)

    Hernandez Rivero, A.; Capote Rodriguez, G.; Padilla Alvarez, R.; Herrera Peraza, E.

    1997-01-01

    Utilization of High Resolution X-Ray Spectrometry preceded by activation of the samples by irradiation with neutron fluxes (NAA-RX) is a relatively modern trend in application of nuclear techniques. This method may complement advantageously the usual Neutron Activation Analysis by means of Gamma Spectrometry (NAA-G). In this work results obtained by the application of NAA-RX for non-destructive analysis of Cuban soil samples are discussed. The samples were irradiated with reactor neutron fluxes and the induced characteristic X-rays were measured by using Si(Li)-detector. Concentrations of Fe, Zn and Eu as determined by NAA-RX are compared with both NAA-G and XRF data. For the elaboration of X-Ray and Gamma Spectra the computer programs AXIL and ACTAN were used respectively. (author) [es

  5. Application of high resolution x-ray spectrometry preceded by neutron activation for elemental analysis of soil samples

    International Nuclear Information System (INIS)

    Hernandez Rivero, A.; Capote Rodriguez, G.; Herrera Peraza, E.

    1996-01-01

    Utilization of High Resolution X-Ray Spectrometry preceded by activation of the samples by irradiation with neutron fluxes (NAA R X) is a relatively modern trend in application of nuclear techniques. This method may complement advantageously the usual Neutron Activation Analysis by means of Gamma Spectrometry (NAA-G) In this work results obtained by the application of NAA-RX for non-destructive analysis of Cuban soil samples are discussed. The samples were irradiated with reactor neutron fluxes and the induced characteristic X-rays were measured by using Si(li)-detector. Concentrations of Fe, Zn and Eu as determined by NAA-RX are compared with both NAA-G and XRF data. For the elaboration of X-ray and Gamma Spectra the computer programs AXIL and ACTAN were used respectively

  6. PREFACE: Structure and dynamics determined by neutron and x-ray scattering Structure and dynamics determined by neutron and x-ray scattering

    Science.gov (United States)

    Müller-Buschbaum, Peter

    2011-06-01

    Neutron and x-ray scattering have emerged as powerful methods for the determination of structure and dynamics. Driven by emerging new, powerful neutron and synchrotron radiation sources, the continuous development of new instrumentation and novel scattering techniques gives rise to exciting possibilities. For example, in situ observations become possible via a high neutron or x-ray flux at the sample and, as a consequence, morphological transitions with small time constants can be detected. This special issue covers a broad range of different materials from soft to hard condensed matter. Hence, different material classes such as colloids, polymers, alloys, oxides and metals are addressed. The issue is dedicated to the 60th birthday of Professor Winfried Petry, scientific director of the Research Neutron Source Heinz Maier-Leibnitz (FRM-II), Germany, advisor at the physics department for the Bayerische Elite-Akademie, chair person of the Arbeitsgemeinschaft Metall- und Materialphysik of the German Physical Society (DPG) and a member of the professional council of the German Science Foundation (Deutsche Forschungsgemeinschaft, DFG). We would like to acknowledge and thank all contributors for their submissions, which made this special issue possible in the first place. Moreover, we would like to thank the staff at IOP Publishing for helping us with the administrative aspects and for coordinating the refereeing process, and Valeria Lauter for the beautiful cover artwork. Finally, to the readers, we hope that you find this special issue a valuable resource that provides insights into the present possibilities of neutron and x-ray scattering as powerful tools for the investigation of structure and dynamics. Structure and dynamics determined by neutron and x-ray scattering contents In situ studies of mass transport in liquid alloys by means of neutron radiography F Kargl, M Engelhardt, F Yang, H Weis, P Schmakat, B Schillinger, A Griesche and A Meyer Magnetic spin

  7. Bone structure investigation using X-ray and neutron radiography techniques

    International Nuclear Information System (INIS)

    Kamali Moghaddam, K.; Taheri, T.; Ayubian, M.

    2008-01-01

    In this paper we report a study of the periodic variation of bone tissue humidity immediately after death using both neutron and X-ray radiography techniques. After death, bone tissue experiences sequential change over time. This change consists of organic and inorganic phase variations of the bone structure, as well as gradual reduction of the bone's water content. These variations are investigated by periodically imaging dead bone using X-ray and neutron radiography. Chemical separation techniques such as calcification and decalcification were used to separate the organic and inorganic phases of the bone. Comparison between X-ray and neutron radiographs of bone following phase separation can be potentially used to investigate the bone disease or to determine a cause of death. In our experiments, we use adult rat femur bones, and the interpretations of these results are presented based on our understanding of bone structure and images produced by neutron and X-ray photon interactions

  8. Bone structure investigation using X-ray and neutron radiography techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kamali Moghaddam, K. [Nuclear Research Center (NRC), Atomic Energy Organization of Iran (AEOI), P.O. Box 11365-8486, Tehran (Iran, Islamic Republic of)], E-mail: kkamali@aeoi.org.ir; Taheri, T.; Ayubian, M. [Nuclear Research Center (NRC), Atomic Energy Organization of Iran (AEOI), P.O. Box 11365-8486, Tehran (Iran, Islamic Republic of)

    2008-01-15

    In this paper we report a study of the periodic variation of bone tissue humidity immediately after death using both neutron and X-ray radiography techniques. After death, bone tissue experiences sequential change over time. This change consists of organic and inorganic phase variations of the bone structure, as well as gradual reduction of the bone's water content. These variations are investigated by periodically imaging dead bone using X-ray and neutron radiography. Chemical separation techniques such as calcification and decalcification were used to separate the organic and inorganic phases of the bone. Comparison between X-ray and neutron radiographs of bone following phase separation can be potentially used to investigate the bone disease or to determine a cause of death. In our experiments, we use adult rat femur bones, and the interpretations of these results are presented based on our understanding of bone structure and images produced by neutron and X-ray photon interactions.

  9. Simultaneous parameter optimization of x-ray and neutron reflectivity data using genetic algorithms

    International Nuclear Information System (INIS)

    Singh, Surendra; Basu, Saibal

    2016-01-01

    X-ray and neutron reflectivity are two non destructive techniques which provide a wealth of information on thickness, structure and interracial properties in nanometer length scale. Combination of X-ray and neutron reflectivity is well suited for obtaining physical parameters of nanostructured thin films and superlattices. Neutrons provide a different contrast between the elements than X-rays and are also sensitive to the magnetization depth profile in thin films and superlattices. The real space information is extracted by fitting a model for the structure of the thin film sample in reflectometry experiments. We have applied a Genetic Algorithms technique to extract depth dependent structure and magnetic in thin film and multilayer systems by simultaneously fitting X-ray and neutron reflectivity data.

  10. Simultaneous parameter optimization of x-ray and neutron reflectivity data using genetic algorithms

    Science.gov (United States)

    Singh, Surendra; Basu, Saibal

    2016-05-01

    X-ray and neutron reflectivity are two non destructive techniques which provide a wealth of information on thickness, structure and interracial properties in nanometer length scale. Combination of X-ray and neutron reflectivity is well suited for obtaining physical parameters of nanostructured thin films and superlattices. Neutrons provide a different contrast between the elements than X-rays and are also sensitive to the magnetization depth profile in thin films and superlattices. The real space information is extracted by fitting a model for the structure of the thin film sample in reflectometry experiments. We have applied a Genetic Algorithms technique to extract depth dependent structure and magnetic in thin film and multilayer systems by simultaneously fitting X-ray and neutron reflectivity data.

  11. Simultaneous parameter optimization of x-ray and neutron reflectivity data using genetic algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Surendra, E-mail: surendra@barc.gov.in; Basu, Saibal [Solid State Physics Division, Bhabha Atomic Research Centre, Mumbai 400085 India (India)

    2016-05-23

    X-ray and neutron reflectivity are two non destructive techniques which provide a wealth of information on thickness, structure and interracial properties in nanometer length scale. Combination of X-ray and neutron reflectivity is well suited for obtaining physical parameters of nanostructured thin films and superlattices. Neutrons provide a different contrast between the elements than X-rays and are also sensitive to the magnetization depth profile in thin films and superlattices. The real space information is extracted by fitting a model for the structure of the thin film sample in reflectometry experiments. We have applied a Genetic Algorithms technique to extract depth dependent structure and magnetic in thin film and multilayer systems by simultaneously fitting X-ray and neutron reflectivity data.

  12. Studies of amyotrophic lateral sclerosis by neutron activation analysis and x-ray microanalysis

    International Nuclear Information System (INIS)

    Iwata, Shiro; Sasajima, Kazuhisa; Yase, Yoshio; Uebayashi, Yushiro; Yoshida, Sohei.

    1976-01-01

    As a mean to elucidate the cause of ALS, the neutron activation method was employed in the analysis of metals contained in environmental samples obtained from areas of high incidence of the disease and in CNS tissue samples of the ALS cases. The X-ray microanalytical method was used to detect the distribution of certain elements including Ca, Al and Mn in spinal cord tissue samples of ALS and control autopsied cases. The results of these studies indicated a possible participation of these metal elements in the microscopic calcification occuring in the degenerated areas of the CNS, and this calcifying mechanism was discussed. (auth.)

  13. PREFACE: Exploring surfaces and buried interfaces of functional materials by advanced x-ray and neutron techniques Exploring surfaces and buried interfaces of functional materials by advanced x-ray and neutron techniques

    Science.gov (United States)

    Sakurai, Kenji

    2010-12-01

    This special issue is devoted to describing recent applications of x-ray and neutron scattering techniques to the exploration of surfaces and buried interfaces of various functional materials. Unlike many other surface-sensitive methods, these techniques do not require ultra high vacuum, and therefore, a variety of real and complicated surfaces fall within the scope of analysis. It must be particularly emphasized that the techniques are capable of seeing even buried function interfaces as well as the surface. Furthermore, the information, which ranges from the atomic to mesoscopic scale, is highly quantitative and reproducible. The non-destructive nature of the techniques is another important advantage of using x-rays and neutrons, when compared with other atomic-scale analyses. This ensures that the same specimen can be measured by other techniques. Such features are fairly attractive when exploring multilayered materials with nanostructures (dots, tubes, wires, etc), which are finding applications in electronic, magnetic, optical and other devices. The Japan Applied Physics Society has established a group to develop the research field of studying buried function interfaces with x-rays and neutrons. As the methods can be applied to almost all types of materials, from semiconductor and electronic devices to soft materials, participants have fairly different backgrounds but share a common interest in state-of-the-art x-ray and neutron techniques and sophisticated applications. A series of workshops has been organized almost every year since 2001. Some international interactions have been continued intensively, although the community is part of a Japanese society. This special issue does not report the proceedings of the recent workshop, although all the authors are in some way involved in the activities of the above society. Initially, we intended to collect quite long overview papers, including the authors' latest and most important original results, as well as

  14. Model independent method to deconvolve hard X-ray spectra

    Energy Technology Data Exchange (ETDEWEB)

    Polcaro, V.F.; Bazzano, A.; Ubertini, P.; La Padula, C. (Consiglio Nazionale delle Ricerche, Frascati (Italy). Lab. di Astrofisica Spaziale); Manchanda, R.K. (Tata Inst. of Fundamental Research, Bombay (India))

    1984-07-01

    A general purpose method to deconvolve the energy spectra detected by means of the use of a hard X-ray telescope is described. The procedure does not assume any form of input spectrum and the observed energy loss spectrum is directly deconvolved into the incident photon spectrum, the form of which can be determined independently of physical interpretation of the data. Deconvolution of the hard X-ray spectrum of Her X-1, detected during the HXR 81M experiment, by the method independent method is presented.

  15. Standardized method for reproducing the sequential X-rays flap

    International Nuclear Information System (INIS)

    Brenes, Alejandra; Molina, Katherine; Gudino, Sylvia

    2009-01-01

    A method is validated to estandardize in the taking, developing and analysis of bite-wing radiographs taken in sequential way, in order to compare and evaluate detectable changes in the evolution of the interproximal lesions through time. A radiographic positioner called XCP® is modified by means of a rigid acrylic guide, to achieve proper of the X ray equipment core positioning relative to the XCP® ring and the reorientation during the sequential x-rays process. 16 subjects of 4 to 40 years old are studied for a total number of 32 registries. Two x-rays of the same block of teeth of each subject have been taken in sequential way, with a minimal difference of 30 minutes between each one, before the placement of radiographic attachment. The images have been digitized with a Super Cam® scanner and imported to a software. The measurements in X and Y-axis for both x-rays were performed to proceed to compare. The intraclass correlation index (ICI) has shown that the proposed method is statistically related to measurement (mm) obtained in the X and Y-axis for both sequential series of x-rays (p=0.01). The measures of central tendency and dispersion have shown that the usual occurrence is indifferent between the two measurements (Mode 0.000 and S = 0083 and 0.109) and that the probability of occurrence of different values is lower than expected. (author) [es

  16. Phase-dependent absorption features in X-ray spectra of X-ray Dim Isolated Neutron Stars

    Science.gov (United States)

    Borghese, A.; Rea, N.; Coti Zelati, F.; Turolla, R.; Tiengo, A.; Zane, S.

    2017-12-01

    A detailed phase-resolved spectroscopy of archival XMM-Newton observations of X-ray Dim Isolated Neutron Stars (XDINSs) led to the discovery of narrow and strongly phase-dependent absorption features in two of these sources. The first was discovered in the X-ray spectrum of RX J0720.4-3125, followed by a new possible candidate in RX J1308.6+2127. Both spectral lines have similar properties: they are detected for only ˜ 20% of the rotational cycle and appear to be stable over the timespan covered by the observations. We performed Monte Carlo simulations to test the significance of these phase-variable features and in both cases the outcome has confirmed the detection with a confidence level > 4.6σ. Because of the narrow width and the strong dependence on the pulsar rotational phase, the most likely interpretation for these spectral features is in terms of resonant proton cyclotron absorption scattering in a confined high-B structure close to the stellar surface. Within the framework of this interpretation, our results provide evidence for deviations from a pure dipole magnetic field on small scales for highly magnetized neutron stars and support the proposed scenario of XDINSs being aged magnetars, with a strong non-dipolar crustal B-field component.

  17. Structure solution from powder neutron and x-ray diffraction data: getting the best of both worlds

    International Nuclear Information System (INIS)

    Hunter, B.A.

    2000-01-01

    Full text: Powder diffraction methods have traditionally been used in three main areas: phase identification and quantification, lattice parameter determination and structure refinement. Until recently structure solution has been the almost exclusive domain of single crystal diffraction methods, predominantly using x-rays. The increasing use of synchrotron and neutron sources, and the unrelenting advances in computing hardware and software means that powder methods are challenging single crystal methods as a practical method for structure solution, especially when single crystal method can not be applied. It is known that structural refinements from a known starting structure using combined X-ray and neutron data sets are capable of providing highly accurate structures. Likewise, using combined x-ray and neutron powder diffraction data in the structure solution process should also be a powerful technique, although to date no one is pursuing this methodology. This paper present examples of solutions to the problem. Namely we are using high resolution powder X-ray and neutron methods to solve the structures of molecular materials and minerals, then refining the structures using both sets of data. In this way we exploit the advantages of both methods while minimising the disadvantages. We present our solution for a small amino acid structure, a metalorganic and a mineral structure

  18. Quasimonochromatic x-ray computed tomography by the balanced filter method using a conventional x-ray source

    International Nuclear Information System (INIS)

    Saito, Masatoshi

    2004-01-01

    A quasimonochromatic x-ray computed tomography (CT) system utilizing balanced filters has recently been developed for acquiring quantitative CT images. This system consisted of basic components such as a conventional x-ray generator for radiography, a stage for mounting and rotating objects, and an x-ray line sensor camera. Metallic sheets of Er and Yb were used as the balanced filters for obtaining quasimonochromatic incident x rays that include the characteristic lines of the W Kα doublet from a tungsten target. The mean energy and energy width of the quasimonochromatic x rays were determined to be 59.0 and 1.9 keV, respectively, from x-ray spectroscopic measurements using a high-purity Ge detector. The usefulness of the present x-ray CT system was demonstrated by obtaining spatial distributions of the linear attenuation coefficients of three selected samples--a 20 cm diameter cylindrical water phantom, a 3.5 cm diameter aluminum rod, and a human head phantom. The results clearly indicate that this apparatus is surprisingly effective for estimating the distribution of the linear attenuation coefficients without any correction of the beam-hardening effect. Thus, implementing the balanced filter method on an x-ray CT scanner has promise in producing highly quantitative CT images

  19. Nuclear Enhanced X-ray Maximum Entropy Method Used to Analyze Local Distortions in Simple Structures

    DEFF Research Database (Denmark)

    Christensen, Sebastian; Bindzus, Niels; Christensen, Mogens

    We introduce a novel method for reconstructing pseudo nuclear density distributions (NDDs): Nuclear Enhanced X-ray Maximum Entropy Method (NEXMEM). NEXMEM offers an alternative route to experimental NDDs, exploiting the superior quality of synchrotron X-ray data compared to neutron data. The method...... proposed to result from anharmonic phonon scattering or from local fluctuating dipoles on the Pb site.[1,2] No macroscopic symmetry change are associated with these effects, rendering them invisible to conventional crystallographic techniques. For this reason PbX was until recently believed to adopt...

  20. X-ray and nuclear methods for comparative analysis of environmental samples

    International Nuclear Information System (INIS)

    Kudryashov, V.I.; Gundorina, S.F.; Frontas'eva, M.V.; Saidmuradov, Zh.

    1988-01-01

    X-ray and instrumental neutron activation methods, and in some cases methods of photon activation (X-ray spectral analysis with proton activation and analysis on the basis of (p, n) reaction) were used to obtain elementary content of different water samples. The possibility of getting space-time dependences of trace elementary concentrations in water (and under certain conditions in atmosphere) is shown. These data are to be used at a complex investigation of sanitary norms of water systems. The advantages of abovementined methods are discussed for obtaining different elementary content in water in different ways

  1. Neutron Stars in X-ray Binaries and their Environments

    Indian Academy of Sciences (India)

    Biswajit Paul

    2017-09-07

    Sep 7, 2017 ... Various recent studies of reprocessing of X-rays in the accretion disk surface .... accretion rate is considered to be the only variable fac- tor that determines ... stellar wind, and any intervening interstellar mate- rial. Reprocessed ...

  2. High performance X-ray and neutron microfocusing optics

    International Nuclear Information System (INIS)

    Gregory Hirsch

    2000-01-01

    The use of extremely small diameter x-ray beams at synchrotron radiation facilities has become an important experimental technique for investigators in many other scientific disciplines. While there have been several different optical elements developed for producing such microbeams, this SBIR project was concerned with one particular device: the tapered-monocapillary optic

  3. Food structure and dynamics - what are the opportunities for x-ray and neutron scattering?

    International Nuclear Information System (INIS)

    Gilbert, Elliot Paul

    2010-01-01

    In the latter part of the 20th century, it became evident that major advances in understanding could be achieved by gathering together scientists from unique, diverse but nonetheless complementary disciplines. To what extent can this be achieved in materials science, food science, food technology and nutrition? In Australia, we have developed a programme of research in which we seek to investigate fundamental and industrial problems of national significance in food science. This presentation will illustrate some of the opportunities now available through strategic alliances with materials scientists in the application of methods such as X-ray and neutron scattering to gain a critical understanding of food microstructure, nanostructure and dynamics

  4. ICF ignition capsule neutron, gamma ray, and high energy x-ray images

    Science.gov (United States)

    Bradley, P. A.; Wilson, D. C.; Swenson, F. J.; Morgan, G. L.

    2003-03-01

    Post-processed total neutron, RIF neutron, gamma-ray, and x-ray images from 2D LASNEX calculations of burning ignition capsules are presented. The capsules have yields ranging from tens of kilojoules (failures) to over 16 MJ (ignition), and their implosion symmetry ranges from prolate (flattest at the hohlraum equator) to oblate (flattest towards the laser entrance hole). The simulated total neutron images emphasize regions of high DT density and temperature; the reaction-in-flight neutrons emphasize regions of high DT density; the gamma rays emphasize regions of high shell density; and the high energy x rays (>10 keV) emphasize regions of high temperature.

  5. Polarized X-Ray Emission from Magnetized Neutron Stars: Signature of Strong-Field Vacuum Polarization

    Science.gov (United States)

    Lai, Dong; Ho, Wynn C.

    2003-08-01

    In the atmospheric plasma of a strongly magnetized neutron star, vacuum polarization can induce a Mikheyev-Smirnov-Wolfenstein type resonance across which an x-ray photon may (depending on its energy) convert from one mode into the other, with significant changes in opacities and polarizations. We show that this vacuum resonance effect gives rise to a unique energy-dependent polarization signature in the surface emission from neutron stars. The detection of polarized x rays from neutron stars can provide a direct probe of strong-field quantum electrodynamics and constrain the neutron star magnetic field and geometry.

  6. Polarized x-ray emission from magnetized neutron stars: signature of strong-field vacuum polarization.

    Science.gov (United States)

    Lai, Dong; Ho, Wynn C G

    2003-08-15

    In the atmospheric plasma of a strongly magnetized neutron star, vacuum polarization can induce a Mikheyev-Smirnov-Wolfenstein type resonance across which an x-ray photon may (depending on its energy) convert from one mode into the other, with significant changes in opacities and polarizations. We show that this vacuum resonance effect gives rise to a unique energy-dependent polarization signature in the surface emission from neutron stars. The detection of polarized x rays from neutron stars can provide a direct probe of strong-field quantum electrodynamics and constrain the neutron star magnetic field and geometry.

  7. Measuring the black hole mass in ultraluminous X-ray sources with the X-ray scaling method

    Science.gov (United States)

    Jang, I.; Gliozzi, M.; Satyapal, S.; Titarchuk, L.

    2018-01-01

    In our recent work, we demonstrated that a novel X-ray scaling method, originally introduced for Galactic black holes (BH), could be reliably extended to estimate the mass of supermassive black holes accreting at moderate to high level. Here, we apply this X-ray scaling method to ultraluminous X-ray sources (ULXs) to constrain their MBH. Using 49 ULXs with multiple XMM-Newton observations, we infer that ULXs host both stellar mass BHs and intermediate mass BHs. The majority of the sources of our sample seem to be consistent with the hypothesis of highly accreting massive stellar BHs with MBH ∼ 100 M⊙. Our results are in general agreement with the MBH values obtained with alternative methods, including model-independent variability methods. This suggests that the X-ray scaling method is an actual scale-independent method that can be applied to all BH systems accreting at moderate-high rate.

  8. Method for reducing x-ray background signals from insertion device x-ray beam position monitors

    Directory of Open Access Journals (Sweden)

    Glenn Decker

    1999-11-01

    Full Text Available A method is described that provides a solution to the long-standing problem of stray radiation-induced signals on photoemission-based x-ray beam position monitors (BPMs located on insertion device x-ray beam lines. The method involves the introduction of a chicane into the accelerator lattice that directs unwanted x radiation away from the photosensitive x-ray BPM blades. This technique has been implemented at the Advanced Photon Source, and experimental confirmation of the technique is provided.

  9. Direct methods for surface X-ray diffraction

    International Nuclear Information System (INIS)

    Saldin, D. K.; Harder, R.; Shneerson, V. L.; Vogler, H.; Moritz, W.

    2000-01-01

    We develop of a direct method for surface X-ray diffraction that exploits the holographic feature of a known reference wave from the substrate. A Bayesian analysis of the optimal inference to be made from an incomplete data set suggests a maximum entropy algorithm that balances agreement with the data and other statistical considerations

  10. X-ray film cassette and method of making

    International Nuclear Information System (INIS)

    1980-01-01

    An x-ray film cassette which is capable of providing forces on the film that vary across the surface of the cassette is described. Methods of manufacture are discussed. The system is of particular use when large area films are used in conjunction with intensifying screens. (U.K.)

  11. Geometric estimation method for x-ray digital intraoral tomosynthesis

    Science.gov (United States)

    Li, Liang; Yang, Yao; Chen, Zhiqiang

    2016-06-01

    It is essential for accurate image reconstruction to obtain a set of parameters that describes the x-ray scanning geometry. A geometric estimation method is presented for x-ray digital intraoral tomosynthesis (DIT) in which the detector remains stationary while the x-ray source rotates. The main idea is to estimate the three-dimensional (3-D) coordinates of each shot position using at least two small opaque balls adhering to the detector surface as the positioning markers. From the radiographs containing these balls, the position of each x-ray focal spot can be calculated independently relative to the detector center no matter what kind of scanning trajectory is used. A 3-D phantom which roughly simulates DIT was designed to evaluate the performance of this method both quantitatively and qualitatively in the sense of mean square error and structural similarity. Results are also presented for real data acquired with a DIT experimental system. These results prove the validity of this geometric estimation method.

  12. Hydrostatic pressure cells development for X-ray and neutron experiments

    International Nuclear Information System (INIS)

    Passamai Junior, Jose Luis

    2010-01-01

    It was developed and built two pressure cell original models in order to be applied in X-ray elastic scattering (X-ray diffraction), X-ray absorption and neutron scattering experiments (neutron diffraction) under hydrostatic pressure. For the first two experimental cases, where X-ray beam is used, the pressure cell built with two B 4 C anvil mounted in a CuBe body. The B 4 C anvil was prepared at CTA research center in order to present an enhanced X-ray transparence and hardness. The special detail and advantage of the CuBe cell with B 4 C anvil is that this cell can be also used to measure de AC magnetic susceptibility in situ. This special characteristic is highlight as new concept of labeled here as multipurpose pressure cell. A second type of cell pressure was developed in order to be used in neutron elastic scattering experiments, specific in neutron diffraction experiments. The neutron cell pressure was developed using carbon fibers composite to improve the mechanical resistance a cylindrical geometry. The B 4 C pressure cells were available to researches in LNLS. The neutron pressure cell was given to research staff of IPEN Nuclear Reactor. This work show details and draws of these two types of hydrostatic pressure cells. (author)

  13. The peculiar galactic center neutron star X-ray binary XMM J174457-2850.3

    Energy Technology Data Exchange (ETDEWEB)

    Degenaar, N.; Reynolds, M. T.; Miller, J. M. [Department of Astronomy, University of Michigan, 500 Church Street, Ann Arbor, MI 48109 (United States); Wijnands, R. [Anton Pannekoek Institute of Astronomy, University of Amsterdam, Science Park 904, 1098 XH Amsterdam (Netherlands); Altamirano, D. [School of Physics and Astronomy, University of Southampton, Highfield, Southampton SO17 1BJ (United Kingdom); Kennea, J. [Department of Astronomy and Astrophysics, 525 Davey Lab, Pennsylvania State University, University Park, PA 16802 (United States); Gehrels, N. [Astrophysics Science Division, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Haggard, D. [CIERA, Physics and Astronomy Department, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208 (United States); Ponti, G., E-mail: degenaar@umich.edu [Max Planck Institute fur Extraterrestriche Physik, D-85748 Garching (Germany)

    2014-09-10

    The recent discovery of a millisecond radio pulsar experiencing an accretion outburst similar to those seen in low mass X-ray binaries, has opened up a new opportunity to investigate the evolutionary link between these two different neutron star manifestations. The remarkable X-ray variability and hard X-ray spectrum of this object can potentially serve as a template to search for other X-ray binary/radio pulsar transitional objects. Here we demonstrate that the transient X-ray source XMM J174457-2850.3 near the Galactic center displays similar X-ray properties. We report on the detection of an energetic thermonuclear burst with an estimated duration of ≅2 hr and a radiated energy output of ≅ 5 × 10{sup 40} erg, which unambiguously demonstrates that the source harbors an accreting neutron star. It has a quiescent X-ray luminosity of L {sub X} ≅ 5 × 10{sup 32}(D/6.5 kpc){sup 2} erg s{sup –1} and exhibits occasional accretion outbursts during which it brightens to L {sub X} ≅ 10{sup 35}-10{sup 36}(D/6.5 kpc){sup 2} erg s{sup –1} for a few weeks (2-10 keV). However, the source often lingers in between outburst and quiescence at L {sub X} ≅ 10{sup 33}-10{sup 34}(D/6.5 kpc){sup 2} erg s{sup –1}. This peculiar X-ray flux behavior and its relatively hard X-ray spectrum, a power law with an index of Γ ≅ 1.4, could possibly be explained in terms of the interaction between the accretion flow and the magnetic field of the neutron star.

  14. A novel x-ray circularly polarized ranging method

    International Nuclear Information System (INIS)

    Song Shi-Bin; Xu Lu-Ping; Zhang Hua; Shen Yang-He; Gao Na

    2015-01-01

    Range measurement has found multiple applications in deep space missions. With more and further deep space exploration activities happening now and in the future, the requirement for range measurement has risen. In view of the future ranging requirement, a novel x-ray polarized ranging method based on the circular polarization modulation is proposed, termed as x-ray circularly polarized ranging (XCPolR). XCPolR utilizes the circular polarization modulation to process x-ray signals and the ranging information is conveyed by the circular polarization states. As the circular polarization states present good stability in space propagation and x-ray detectors have light weight and low power consumption, XCPolR shows great potential in the long-distance range measurement and provides an option for future deep space ranging. In this paper, we present a detailed illustration of XCPolR. Firstly, the structure of the polarized ranging system is described and the signal models in the ranging process are established mathematically. Then, the main factors that affect the ranging accuracy, including the Doppler effect, the differential demodulation, and the correlation error, are analyzed theoretically. Finally, numerical simulation is carried out to evaluate the performance of XCPolR. (paper)

  15. Unambiguous determination of H-atom positions: comparing results from neutron and high-resolution X-ray crystallography.

    Science.gov (United States)

    Gardberg, Anna S; Del Castillo, Alexis Rae; Weiss, Kevin L; Meilleur, Flora; Blakeley, Matthew P; Myles, Dean A A

    2010-05-01

    The locations of H atoms in biological structures can be difficult to determine using X-ray diffraction methods. Neutron diffraction offers a relatively greater scattering magnitude from H and D atoms. Here, 1.65 A resolution neutron diffraction studies of fully perdeuterated and selectively CH(3)-protonated perdeuterated crystals of Pyrococcus furiosus rubredoxin (D-rubredoxin and HD-rubredoxin, respectively) at room temperature (RT) are described, as well as 1.1 A resolution X-ray diffraction studies of the same protein at both RT and 100 K. The two techniques are quantitatively compared in terms of their power to directly provide atomic positions for D atoms and analyze the role played by atomic thermal motion by computing the sigma level at the D-atom coordinate in simulated-annealing composite D-OMIT maps. It is shown that 1.65 A resolution RT neutron data for perdeuterated rubredoxin are approximately 8 times more likely overall to provide high-confidence positions for D atoms than 1.1 A resolution X-ray data at 100 K or RT. At or above the 1.0sigma level, the joint X-ray/neutron (XN) structures define 342/378 (90%) and 291/365 (80%) of the D-atom positions for D-rubredoxin and HD-rubredoxin, respectively. The X-ray-only 1.1 A resolution 100 K structures determine only 19/388 (5%) and 8/388 (2%) of the D-atom positions above the 1.0sigma level for D-rubredoxin and HD-rubredoxin, respectively. Furthermore, the improved model obtained from joint XN refinement yielded improved electron-density maps, permitting the location of more D atoms than electron-density maps from models refined against X-ray data only.

  16. Elemental investigation of talcum baby powder by X-Ray florescence and fast neutron activation Techniques

    International Nuclear Information System (INIS)

    Hassan, M. F.; Abd El Wahab, M.; Nada, A.

    2008-01-01

    Different samples of Egyptian and Hungarian talcum powders were studied, using X-ray florescence (XRF) and Fast Neutron Activation Analysis (FNAA) techniques to ensure the safety of its use. The K (X-rays) and the gamma-rays were measured, using Si(Li) and high-purity germanium (HPGe) spectrometers to detect and determine qualitatively and quantitatively the constituents of the studied samples. The concentrations of the elements (Mg, Si, Al, Fe, Zn, and Ba) were measured and their presence was confirmed by X-ray, lifetime and/or XRF measurements. One of these samples was also studied, using the Environmental Scanning Electron Microscope (ESEM)

  17. Effects of fission neutrons and X-rays on the epithelium of the mouse stomach

    International Nuclear Information System (INIS)

    Kingma-ter Haar, J.M.

    1982-07-01

    A quantitative study is presented of the effects of whole-body irradiation on the stomach of mice. Two types of ionizing radiation were compared - fast fission neutrons of 1.0 MeV mean energy and 300 kVp X-rays. The effects on the functional cell populations, on gastric secretion and on gastric stem cell populations were studied. These effects have been investigated a) for a neutron dose in the lethal dose-range of 4.0 Gy as a function of time and b) at a post-irradiation interval of 3 weeks as a function of neutron and X-ray dose. (Auth.)

  18. The 7th Japan-Taiwan joint meeting on neutron and X-ray scattering. Proceedings

    International Nuclear Information System (INIS)

    2016-03-01

    The 7th Japan-Taiwan joint meeting on neutron and X-ray scattering in Kumatori is held bilaterally in Japan and Taiwan. This meeting provides the recent outstanding results in the fields of fundamental polymer and biological sciences and their applications as well. In the fields of the X-ray and/or neutron scattering, the methodological progress expands the research fields and gives us new scientific insights. This meeting invites the researchers developing new methodologies, such as dynamics measurement utilizing nuclear Bragg resonance, subunit-kinetics measurement with deuteration-assisted small-angle neutron scattering and so on. (J.P.N.)

  19. Discriminated neutron and X-ray radiography using multi-color scintillation detector

    International Nuclear Information System (INIS)

    Nittoh, Koichi; Takahara, Takeshi; Yoshida, Tadashi; Tamura, Toshiyuki

    1999-01-01

    A new conversion screen Gd 2 O 2 S:Eu is developed, which emits red light on irradiation by thermal neutrons. By applying this in combination with the currently used Gd 2 O 2 S:Tb, a green-light scintillator, in the radiography under a neutron + X-ray coexisting field, we can easily separate the neutron image and the X-ray image by simple color-image processing. This technique enables a non-destructive and detailed inspection of industrial products composed both of light elements (water, plastics, etc.) and heavy elements (metals), widening the horizon of new applications

  20. Discriminated neutron and X-ray radiography using multi-color scintillation detector

    CERN Document Server

    Nittoh, K; Yoshida, T; Tamura, T

    1999-01-01

    A new conversion screen Gd sub 2 O sub 2 S:Eu is developed, which emits red light on irradiation by thermal neutrons. By applying this in combination with the currently used Gd sub 2 O sub 2 S:Tb, a green-light scintillator, in the radiography under a neutron + X-ray coexisting field, we can easily separate the neutron image and the X-ray image by simple color-image processing. This technique enables a non-destructive and detailed inspection of industrial products composed both of light elements (water, plastics, etc.) and heavy elements (metals), widening the horizon of new applications.

  1. Hydrostatic pressure cells development for X-ray and neutrons experiments

    International Nuclear Information System (INIS)

    Passamai Junior, Jose Luis; Pinheiro, Christiano J.G.; Orlando, Marcos Tadeu D.; Passos, Carlos A.C.; Rossi, Jesualdo L.; Mazzocchi, Vera L.; Parente, Carlos B.R.; Mestnik Filho, Jose; Martinez, Luis G.; Melo, Francisco C.L. de

    2011-01-01

    A set of hydrostatic pressure cells was specially developed in order to be applied in X-ray diffraction, X-ray absorption and neutron diffraction experiments. For the experiments where X-rays are used, the pressure cells are built in a CuBe alloy body with two B 4 C anvils in order to allow the low absorption of the radiation. The B 4 C anvils were specially prepared in CTA - Centro Tecnico Aeroespacial - Sao Jose dos Campos - Brazil, in order to present enhanced X-ray transparency and high hardness. One of the advantage of the CuBe-body cell with B 4 C anvil is that it can be also used under magnetic fields, for instance for measurements of AC magnetic susceptibility under high hydrostatic pressures. The X-ray cells work in transmission mode and present a 2 mm diameter hole for the beam path. The X-ray beam pass through the hole and outgoing to the detector positioned in front of the pressure cell. A second type of pressure cell was developed in order to be used in neutron elastic scattering experiments, especially in neutron diffraction experiments. The neutron cell pressure cell was constructed in Zirconium alloy reinforced with carbon fibers composite in order to improve the mechanical resistance of his cylindrical geometry. The B 4 C pressure cells are available to users of the techniques of X-ray diffraction and absorption in the Brazilian National Synchrotron Laboratory - LNLS, at Campinas City. The neutron pressure cell is available to users at the neutron powder diffraction facility installed at the Nuclear and Energy Research Institute - IPEN, Sao Paulo. In this work will be shown details and drawings of the two types of hydrostatic pressure cells. (author)

  2. Dehydration reactions of gypsum: A neutron and X-ray diffraction study

    Science.gov (United States)

    Abriel, W.; Reisdorf, K.; Pannetier, J.

    1990-03-01

    The kinetics of the dehydration of gypsum was investigated by powder diffraction methods. Using the incoherent scattering effect of H with the neutron beam, the background intensity as a measure of the water content was checked in the temperature range 295-623 K. The superposed Bragg peaks yielded four major phases: Gypsum, subhydratesCaSO 4(H 2O) x (1 > x > 0),AIII-CaSO 4, AII-CaSO 4. For the subhydrates a maximum water content of x > = 0.74was determined. A different kinetic was found using Guinier X-ray technique with the heated sample prepared on a thin foil. Only with high local H 2O steam pressure, produced in the comparable larger sample container of the neutron diffraction experiment, could this high H 2O occupation of the subhydrate tunnel structure be found. A topotactic mechanism can describe the phase transitions for this reaction.

  3. Repair in mouse lung of multifraction X rays and neutrons: extension to 40 fractions

    International Nuclear Information System (INIS)

    Parkins, C.S.; Fowler, J.F.

    1985-01-01

    Repair parameters were calculated from measurements of breathing rate and lethality at monthly intervals up to 17 months after irradiation with 1, 10, 20 or 40 equal fractions, down to 1.1 Gy of x-rays and 0.18 Gy of 3 MeV neutrons per fraction. Sparing of neutron damage was negligible when the neutron dose was divided into multiple fractions; progressively greater repair of lung damage was seen after increasing x-ray fractions. Significant increase in the iso-effect dose for 40 x-ray fractions was found compared with 20, even at two fractions per day at six hour intervals, as was the case in the 40 fraction experiment. Data were well fitted by the linear quadratic formula for response vs. dose per fraction and the ratio γ/β yielded values of approx. 3 Gy after x-rays and 30 to 40 Gy after neutron irradiation, not different from γ/β ratios found for up to 20 fractions. Single dose RBE was less than 2, increasing to about six at the lowest dose per fraction measured, agreeing with previous results. The ratio of the γ component for neutrons to that for x-rays was approx. 8, which is therefore the limiting RBE predicted for infinitely small fractional doses. (U.K.)

  4. Apoptosis in thymocytes and lymphoma cells induced by neutrons and X-rays

    International Nuclear Information System (INIS)

    Ohyama, Harumi; Koike, Sachiko; Ando, Kouichi

    1993-01-01

    Apoptosis is a distinctive mode of programmed cell death with characteristic morphological and biochemical features. The cells undergoing apoptosis display shrinkage, chromatin condensation and internucleosomal breakage of DNA. The cell death is a process through which organisms get rid of unwanted cells. Thymocytes are highly radiosensitive, and undergo typical apoptosis within a few hours after the exposure to X-ray. Also extremely radiosensitive thymic lymphoma cells have been found. The effect of 30 MeV NIRS fast neutrons on the induction of apoptosis in thymocytes and thymoma cells was examined in comparison with that of X-ray. Although apoptotic cells increased gradually with time, the apoptotic process proceeded rapidly in individual cells after the onset. By the measurement of cell size distribution, the appearance of a distinct apoptotic cell peak was observed. In the case of neutron irradiation on SCA1 thymic lymphoma cells, the method for counting apoptotic cells based on chromatin condensation was developed. The cell volume reduction of thymocytes, the dose survival curves and the induction of apoptosis in SCA1 are reported. (K.I.)

  5. NATO Advanced Study Institute on Chemical Crystallography with Pulsed Neutrons and Synchrotron X-Rays

    CERN Document Server

    Jeffrey, George

    1988-01-01

    X-ray and neutron crystallography have played an increasingly impor­ tant role in the chemical and biochemical sciences over the past fifty years. The principal obstacles in this methodology, the phase problem and com­ puting, have been overcome. The former by the methods developed in the 1960's and just recognised by the 1985 Chemistry Nobel Prize award to Karle and Hauptman, the latter by the dramatic advances that have taken place in computer technology in the past twenty years. Within the last decade, two new radiation sources have been added to the crystallographer's tools. One is synchrotron X-rays and the other is spallation neutrons. Both have much more powerful fluxes than the pre­ vious sources and they are pulsed rather than continuos. New techniques are necessary to fully exploit the intense continuos radiation spectrum and its pulsed property. Both radiations are only available from particular National Laboratories on a guest-user basis for scientists outside these Na­ tional Laboratories. Hi...

  6. Residual stress measurements by X-ray and neutron diffractions in heat-treated SiCw/A2014 composites

    International Nuclear Information System (INIS)

    Ohnuki, Takahisa; Fujita, Motoo; Tomota, Yo; Ono, Masayoshi

    1998-01-01

    Residual stresses due to various heat treatments in a 22 volume percent SiC whisker/A2014 metal matrix composite (MMC) were measured by using X-ray and neutron diffractions. Micro residual stresses generated from the differences in thermal expansion coefficients of the constituents and macro residual stresses associated with different cooling rates in the outer and inner regions of an MMC specimen must be distinguished in X-ray stress measurements. The conventional sin 2 ψ method under an assumption of plane stress condition has been found not to be applicable to the present MMC, because interactions among whiskers in the X-ray penetrating area yields σ 33 where the x 3 -axis is normal with respect to specimen's surface. An average value of σ 33 can be measured by X-ray diffraction technique, but does not seem enough to evaluate micro residual stresses. It is found that neutron diffraction is the most powerful method to measure micro residual stresses in the constituents. Elastic residual strains obtained by neutron diffraction in solution treated or T6 heat treated samples show good agreements with predictions calculated by using Eshelby inclusion theory coupled with the Mori-Tanaka mean field concept, indicating that the influence of stress relaxation is negligible. In addition, internal stresses relaxations during holding at room temperature, slow cooling from solution treatment temperature, or subzero cooling are discussed. (author)

  7. A Michelson interferometer for X-rays and thermal neutrons

    International Nuclear Information System (INIS)

    Appel, A.

    1992-01-01

    The introduced interferometer consists of an LLL interferometer and a phase-displacing Bragg groove component. A part of the radiation path between the Lane mirrors in the Bragg grooves is replaced by a radiation path, whose wave number vector has a slightly different direction compared to the Lane case by the refraction correction. If the angles of incidence in the two grooves are different, then a difference in path is produced between the beams producing interference. This is the first X-ray interferometer which works like an optical Michelson interferometer. As there are no basic limits to resolution by absorption or dispersion, for example, it opens up the possibility of carrying out Fourier spectroscopy in the A wavelength range. (orig.) [de

  8. Structure of Insulin: Results of joint neutron and X-ray refinement

    Energy Technology Data Exchange (ETDEWEB)

    Wlodawer, A; Savage, H; Dodson, G

    1989-02-01

    Neutron diffraction data for porcine 2Zn insulin were collected to 2.2 A resolution from a single crystal deuterated by slow exchange of mother liquor. A joint neutron/X-ray restrained-least-squares refinement was undertaken using the neutron data, as well as the 1.5 A resolution X-ray data collected previously. The final R factors were 0.182 for the X-ray data and 0.191 for the neutron data. Resulting atomic coordinates were compared with the initial X-ray model, showing a total r.m.s. shift of 0.36 A for the protein and 0.6 A for the solvent. Protonation of a number of individual amino acids was investigated by analysis of the neutron maps. No D atoms were found between the carboxylates of Glu B13 which make an intermolecular contact, suggesting nonbonded interaction rather than the predicted hydrogen bond. Amide hydrogen exchange was investigated in a refinement of their atomic occupancies. Regions of unexchanged amide groups were found in the center of the B helices. The results of this study emphasize the limited amount of information available in neutron diffraction studies of proteins at resolution lower than 2 A.

  9. Analysis of fresco paintings by X-ray fluorescence method

    International Nuclear Information System (INIS)

    Cechak, T.; Gerndt, J.; Musilek, L.; Kopecka, I.

    2000-01-01

    In this work we present the application of X-ray fluorescence analysis (XRFA) to examine fresco paintings from the Karlstejn castle. The X-ray fluorescence apparatus built and operated in the Laboratory of Quantitative Methods in Research of Ancient Monuments was used for the purpose of fresco paintings measurements. The X-ray sources (radionuclides) generate the characteristic X-ray photons from the sample. The Si(Li) detector measures numbers and energies of photons emitted from the specimen. The energy and number of photons detected can be converted into kind and amount of measured atoms. These results give data for qualitative and quantitative analysis of samples. XRFA is relatively simple and non-destructive method. Capability of in-situ measurement is one of big advantages of this method. The radionuclide sources of exciting radiation (e.g. 55 Fe enables the excitation of elements with Z up to 23, 238 Pu is used in interval of Z from 20 to 39 etc.) were used. An Si(Li) semiconductor detector with a 5 l Dewar vessel and portable spectroscopy system enable the in situ measurement. Narrow collimation of the exciting beam makes it possible to select the measured area of fresco painting. The valuable fresco paintings from the Karlstejn castle were investigated in this way. The measurements were carried out in collaboration with the Analytical Laboratory of the State Institute for the Preservation of Historic Monuments. A suitable analysis of paintings makes it possible to detect the kind of colours and evaluate changes in the surface colour of paintings and suggest useful and timely procedures for their conservation and restoration. (author)

  10. X-ray and gamma ray waveguide, cavity and method

    International Nuclear Information System (INIS)

    Vali, V.; Krogstad, R.S.; Willard, H.R.

    1978-01-01

    An x-ray and gamma ray waveguide, cavity, and method for directing electromagnetic radiation of the x-ray, gamma ray, and extreme ultraviolet wavelengths are described. A hollow fiber is used as the waveguide and is manufactured from a material having an index of refraction less than unity for these wavelengths. The internal diameter of the hollow fiber waveguide and the radius of curvature for the waveguide are selectively predetermined in light of the wavelength of the transmitted radiation to minimize losses. The electromagnetic radiation is obtained from any suitable source ad upon introduction into the waveguide is transmitted along a curvilinear path. The waveguide may be formed as a closed loop to create a cavity or may be used to direct the electromagnetic radiation to a utilization site

  11. Compositional Determination of Shale with Simultaneous Neutron and X-ray Tomography

    Science.gov (United States)

    LaManna, J.; Hussey, D. S.; Baltic, E.; Jacobson, D. L.

    2017-12-01

    Understanding the distribution of organic material, mineral inclusions, and porosity are critical to properly model the flow of fluids through rock formations in applications ranging from hydraulic fracturing and gas extraction, CO2 sequestration, geothermal power, and aquifer management. Typically, this information is obtained on the pore scale using destructive techniques such as focused ion beam scanning electron microscopy. Neutrons and X-rays provide non-destructive, complementary probes to gain three-dimensional distributions of porosity, minerals, and organic content along with fluid interactions in fractures and pore networks on the core scale. By capturing both neutron and X-ray tomography simultaneously it is possible to capture slowly dynamic or stochastic processes with both imaging modes. To facilitate this, NIST offers a system for simultaneous neutron and X-ray tomography at the Center for Neutron Research. This instrument provides neutron and X-ray beams capable of penetrating through pressure vessels to image the specimen inside at relevant geological conditions at resolutions ranging from 15 micrometers to 100 micrometers. This talk will discuss current efforts at identifying mineral and organic content and fracture and wettability in shales relevant to gas extraction.

  12. The structure of para-toluidine by X-ray and neutron diffraction

    International Nuclear Information System (INIS)

    Bertinotti, A.L.

    1965-12-01

    The crystal and molecular structure of para-toluidine has been solved by X-ray and neutron diffraction counter techniques. The molecules are arranged in the form of infinite chains in the crystal, each molecule being linked to two neighbours by hydrogen bonds. The presence of the H bonds makes clear the difference in the melting points between para-toluidine and benzene hydrocarbons of related symmetry and molecular weight. Their direction accounts for the (001) cleavage and the growth anisotropy of crystals from supersaturated vapour phase. A structure-seeking method by computer has been elaborated, using lattice energy calculations applied to molecules treated as rigid bodies and making use of a simplex method for function minimization without calculation of derivatives. The way the available information is handled allows to increase the range of convergence, as shown in the case of para-toluidine. (author) [fr

  13. REFINED NEUTRON STAR MASS DETERMINATIONS FOR SIX ECLIPSING X-RAY PULSAR BINARIES

    International Nuclear Information System (INIS)

    Rawls, Meredith L.; Orosz, Jerome A.; McClintock, Jeffrey E.; Torres, Manuel A. P.; Bailyn, Charles D.; Buxton, Michelle M.

    2011-01-01

    We present an improved method for determining the mass of neutron stars in eclipsing X-ray pulsar binaries and apply the method to six systems, namely, Vela X-1, 4U 1538-52, SMC X-1, LMC X-4, Cen X-3, and Her X-1. In previous studies to determine neutron star mass, the X-ray eclipse duration has been approximated analytically by assuming that the companion star is spherical with an effective Roche lobe radius. We use a numerical code based on Roche geometry with various optimizers to analyze the published data for these systems, which we supplement with new spectroscopic and photometric data for 4U 1538-52. This allows us to model the eclipse duration more accurately and thus calculate an improved value for the neutron star mass. The derived neutron star mass also depends on the assumed Roche lobe filling factor β of the companion star, where β = 1 indicates a completely filled Roche lobe. In previous work a range of β between 0.9 and 1.0 was usually adopted. We use optical ellipsoidal light-curve data to constrain β. We find neutron star masses of 1.77 ± 0.08 M sun for Vela X-1, 0.87 ± 0.07 M sun for 4U 1538-52 (eccentric orbit), 1.00 ± 0.10 M sun for 4U 1538-52 (circular orbit), 1.04 ± 0.09 M sun for SMC X-1, 1.29 ± 0.05 M sun for LMC X-4, 1.49 ± 0.08 M sun for Cen X-3, and 1.07 ± 0.36 M sun for Her X-1. We discuss the limits of the approximations that were used to derive the earlier mass determinations, and we comment on the implications our new masses have for observationally refining the upper and lower bounds of the neutron star mass distribution.

  14. X-ray and neutron scattering studies of complex confined fluids

    International Nuclear Information System (INIS)

    Sinha, S. K.

    1999-01-01

    We review recent X-ray and neutron scattering studies of the structure and dynamics of confined complex fluids. This includes the study of polymer conformations and binary fluid phase transitions in porous media using Small Angle Neutron scattering, and the use of synchrotrons radiation to study ordering and fluctuation phenomena at solid/liquid and liquid/air interfaces. Ordering of liquids near a solid surface or in confinement will be discussed, and the study, via specular and off-specular X-ray reflectivity, of capillary wave fluctuations on liquid polymer films. Finally, we shall discuss the use of high-brilliance beams from X-ray synchrotrons to study via photon correlation spectroscopy the slow dynamics of soft condensed matter systems

  15. Methods for X-ray examinations of the maxillodental system

    International Nuclear Information System (INIS)

    Rabukhina, N.A.; Arzhantsev, A.P.

    1992-01-01

    Only two roentgenography methods (periapical and occlusion) are used for production of dental roentgenograms. Periapical survey must be used only for revealing state of bone tissue around tooth root tops. In parodontology it is necessary to use occlusion survey. Perfection of the methods and improvement of quality of tooth roentgenograpms demand to change the design of native dental X-ray unit: elongation of its tube, increase of radiator power. Introduction of orthopantomography as basis method of roengenography in stomatology is the most radical decision of methodological problems. Orthopantomography is replaced by intra- and extra-oral roentgenography of teeth and jaws

  16. Improvement of mungbean by X-ray and thermal neutron irradiation

    International Nuclear Information System (INIS)

    Kwon, S.H.; Oh, J.H.

    1983-01-01

    With the aim of improving yield, resistance to Cercospora leaf spot and pod shattering, mungbean varieties Kyunggi No. 5 and M-317 were irradiated with X-rays and thermal neutrons. High yielding mutant lines are generally characterized by a higher number of pods per plant. Better Cercospora resistance appears often associated with later maturity. Satisfactory shattering resistance was not yet obtained. (author)

  17. Analysis of microstress in neutron irradiated polyester fibre by X-ray ...

    Indian Academy of Sciences (India)

    Unknown

    Abstract. Microstresses developed in the crystallites of polymeric material due to irradiation of high-energy particle causes peak broadening and shifting of X-ray diffraction lines to lower angle. Neutron irradiation significantly changes the material properties by displacement of lattice atoms and the generation of helium.

  18. Small angle neutron scattering and small angle X-ray scattering ...

    Indian Academy of Sciences (India)

    Abstract. The morphology of carbon nanofoam samples comprising platinum nanopar- ticles dispersed in the matrix was characterized by small angle neutron scattering (SANS) and small angle X-ray scattering (SAXS) techniques. Results show that the structure of pores of carbon matrix exhibits a mass (pore) fractal nature ...

  19. Composite structure of helicopter rotor blades studied by neutron- and X-ray radiography

    International Nuclear Information System (INIS)

    Balasko, M.; Veres, I.; Molnar, Gy.; Balasko, Zs.; Svab, E.

    2004-01-01

    In order to inspect the possible defects in the composite structure of helicopter rotor blades combined neutron- and X-ray radiography investigations were performed at the Budapest Research Reactor. Imperfections in the honeycomb structure, resin rich or starved areas at the core-honeycomb surfaces, inhomogeneities at the adhesive filling and water percolation at the sealing interfaces of the honeycomb sections were discovered

  20. Composite structure of helicopter rotor blades studied by neutron- and X-ray radiography

    Science.gov (United States)

    Balaskó, M.; Veres, I.; Molnár, Gy.; Balaskó, Zs.; Sváb, E.

    2004-07-01

    In order to inspect the possible defects in the composite structure of helicopter rotor blades combined neutron- and X-ray radiography investigations were performed at the Budapest Research Reactor. Imperfections in the honeycomb structure, resin rich or starved areas at the core-honeycomb surfaces, inhomogeneities at the adhesive filling and water percolation at the sealing interfaces of the honeycomb sections were discovered.

  1. X-ray luminosity by matter accretion on a neutron star

    Energy Technology Data Exchange (ETDEWEB)

    Baroni, L [Bologna Univ. (Italy). Ist. di Fisica; Fortini, P L [Instituto di Astronomia, Bologna (Italy); Gualdi, C; Callegari, G [Ferrara Univ. (Italy). Ist. di Fisica

    1980-11-20

    When the accretion rate on a non magnetic neutron star is determined by stellar wind and not by overflowing the Roche lobe, it is shown that X-ray luminosity cannot exceed 10sup(36)-10sup(37) erg/sec. This very low limit is essentially set by radiation pressure which causes an effective braking on the falling matter.

  2. An ultraluminous X-ray source powered by an accreting neutron star

    DEFF Research Database (Denmark)

    Bachetti, M.; Harrison, F. A.; Walton, D. J.

    2014-01-01

    the Eddington limit for a 1.4-solar-mass object, or more than ten times brighter than any known accreting pulsar. This implies that neutron stars may not be rare in the ultraluminous X-ray population, and it challenges physical models for the accretion of matter onto magnetized compact objects....

  3. PREFACE: Workshop on 'Buried' Interface Science with X-rays and Neutrons

    Science.gov (United States)

    Sakurai, Kenji

    2007-06-01

    The 2007 workshop on `buried' interface science with X-rays and neutrons was held at the Institute of Materials Research, Tohoku University, in Sendai, Japan, on July 22-24, 2007. The workshop was the latest in a series held since 2001; Tsukuba (December 2001), Niigata (September 2002), Nagoya (July 2003), Tsukuba (July 2004), Saitama (March 2005), Yokohama (July 2006), Kusatsu (August 2006) and Tokyo (December 2006). The 2007 workshop had 64 participants and 34 presentations. There are increasing demands for sophisticated metrology in order to observe multilayered materials with nano-structures (dots, wires, etc), which are finding applications in electronic, magnetic, optical and other devices. Unlike many other surface-sensitive methods, X-ray and neutron analysis is known for its ability to see even `buried' function interfaces as well as the surface. It is highly reliable in practice, because the information, which ranges from the atomic to mesoscopic scale, is quantitative and reproducible. The non-destructive nature of this type of analytical method ensures that the same specimen can be measured by other techniques. However, we now realize that the method should be upgraded further to cope with more realistic problems in nano sciences and technologies. In the case of the reflectivity technique and other related methods, which have been the main topics in our workshops over the past 7 years, there are three important directions as illustrated in the Figure. Current X-ray methods can give atomic-scale information for quite a large area on a scale of mm2-cm2. These methods can deliver good statistics for an average, but sometimes we need to be able to see a specific part in nano-scale rather than an average structure. In addition, there is a need to see unstable changing structures and related phenomena in order to understand more about the mechanism of the functioning of nano materials. Quick measurements are therefore important. Furthermore, in order to apply

  4. The effect of surface texture on total reflection of neutrons and X-rays from modified interfaces

    DEFF Research Database (Denmark)

    Goldar, A.; Roser, S.J.; Hughes, A.

    2002-01-01

    X-ray and neutron scattering from macroscopically rough surfaces and interfaces is considered and a new method of analysis based on the variation of the shape of the total reflection edge in the reflectivity profile is proposed. It was shown that in the limit that the correlation length and the h......X-ray and neutron scattering from macroscopically rough surfaces and interfaces is considered and a new method of analysis based on the variation of the shape of the total reflection edge in the reflectivity profile is proposed. It was shown that in the limit that the correlation length...... and the height of the surface roughness are larger than the wavelength (at least 100 times bigger) of the incoming beam, the total reflection edge in the reflection profile becomes rounded. This technique allows direct analysis of the variation of the reflectivity pro le in terms of the structure of the surface...

  5. Thermal states of coldest and hottest neutron stars in soft X-ray transients

    OpenAIRE

    Yakovlev, D. G.; Levenfish, K. P.; Potekhin, A. Y.; Gnedin, O. Y.; Chabrier, G.

    2003-01-01

    We calculate the thermal structure and quiescent thermal luminosity of accreting neutron stars (warmed by deep crustal heating in accreted matter) in soft X-ray transients (SXTs). We consider neutron stars with nucleon and hyperon cores and with accreted envelopes. It is assumed that an envelope has an outer helium layer (of variable depth) and deeper layers of heavier elements, either with iron or with much heavier nuclei (of atomic weight A > 100) on the top (Haensel & Zdunik 1990, 2003, as...

  6. Method of X-ray examination of upper respiratory tracts

    International Nuclear Information System (INIS)

    Portnoj, L.M.; Surenchik, V.I.; Shuster, M.A.; Sal'nikova, Eh.A.

    1982-01-01

    Method of X-ray examination of upper respiratory tracts by radiography both in direct and lateral projection with an introduction of radiocontrast media through tracheostoma is described. The main objective of the invention is to improve accuracy of diagnostics of larynx and trachea cicatrix structures in children. The objective is attained by the examination under general anesthesia; barium sulfate is simultaneously introduced through laryngoscope and tracheostoma, and polypositional radiography is accomplished just in the moment of air introduction under 130-170 mm Hg pressure in the amounts of 60-200 ml

  7. A portable x-ray source and method for radiography

    International Nuclear Information System (INIS)

    Golovanivsky, K.S.

    1996-01-01

    A portable x-ray source that produces a sufficient x-ray flux to produce high quality x-ray images on x-ray films. The source includes a vacuum chamber filled with a heavy atomic weight gas at low pressure and an x-ray emitter. The chamber is in a magnetic field and an oscillating electric field and generates electron cyclotron resonance (ECR) plasma having a ring of energetic electrons inside the chamber. The electrons bombard the x-ray emitter which in turn produces x-ray. A pair of magnetic members generate an axisymmetric magnetic mirror trap inside the chamber. The chamber may be nested within a microwave resonant cavity and between the magnets or the chamber and the microwave cavity may be a single composite structure. (author)

  8. Focussing X-rays, gamma rays and neutrons

    International Nuclear Information System (INIS)

    Smither, R.K.

    1982-01-01

    A diffraction crystal or grating has a face for receiving a beam of photons or neutrons and diffraction planar spacing or grating spacing along that face with the spacing increasing progressively along the face to provide a decreasing Bragg diffraction angle for a monochromatic radiation and thereby increasing the usable area and acceptance angle. The increased planar spacing for a diffraction crystal is provided by the use of a temperature differential across the crystalline structure, by assembling a plurality of crystalline structures with different compositions, by an individual crystalline structure with a varying composition and thereby a changing planar spacing along its face, and by combinations of these techniques. (author)

  9. Neutron, x-ray scattering and TEM studies of Ni-Ti multilayers

    International Nuclear Information System (INIS)

    Keem, J.E.; Wood, J.; Grupido, N.; Hart, K.; Nutt, S.; Reichel, D.G.; Yelon, W.B.

    1988-01-01

    The authors present an analysis of Ni-Ti multilayer neutron reflectors and supermirrors undertaken to identify the causes of the lower than expected observed scattering power and critical angle enhancement of Ni-Ti supermirrors. Results of these investigations focus attention on cusp formation in the Ni-Ti bilayers as probable cause for the reduced neutron scattering power. Grazing angle x-ray and neutron scattering, wide angle neutron diffraction and analytical cross sectional TEM have been used. The multilayers were produced by magnetron sputtering and ion-beam deposition on float glass substrates and silicon wafers

  10. Prenatal death and malformations after irradiation of mouse zygotes with neutrons or X-rays

    International Nuclear Information System (INIS)

    Pampfer, S.; Streffer, C.

    1988-01-01

    Female mice (strain: Heiligenberger Stamm) were irradiated with neutrons (7 MeV) or X-rays when embryos were at the early zygote stage; uterine contents were examined on gestation day 19 for prenatal mortality and malformed fetuses. For both radiation qualities, the dose-dependent survival curve fitted well to a simple exponential equation; the neutron relative biological efficiency (RBE) value was 2.3. The major fraction of deaths induced by exposure to neutrons or X-rays occurred before implantation. Aside from dead embryos, malformed fetuses were observed 19 days p.c. (postconception). The number of malformed fetuses increased with a linear-quadratic function of neutron or X-ray dose. Malformations were mainly gastroschisis, although omphaloceles and anencephalies were also observed. The neutron RBE value for the induction of malformations varied from 2.0 to 2.8 in the dose range tested. Except after 75-cGy neutrons, no significant increase in the proportion of stunted or skeletally malformed fetuses was noted. Our results indicated that the reaction of preimplantation embryos to irradiation could be more complex than the simple all-or-none response considered so far

  11. Neutron and synchrotorn x-ray small angle scattering instruments for applications in biology at the Brookhaven National Laboratory

    International Nuclear Information System (INIS)

    Schoenborn, B.P.; Wise, D.S.; Schneider, D.K.

    1983-01-01

    Facilities for small angle x-ray and neutron scattering are described, with emphasis on the characterization of the primary beam of the neutron instrument and the spectrometer control logic of the synchrotron instrument

  12. Neutron and x-ray scattering studies of ferroelectric phase transitions

    International Nuclear Information System (INIS)

    Dolling, G.

    1982-08-01

    The subject of ferroelectric type phase transitions is introduced by means of examples of two main classes (a) displacive transitions, e.g. KNbO 3 , and (b) order-disorder transitions, e.g. NaNO 2 . The significance of crystal structure and crystal dynamics (i.e. the phonon dispersion relations) for ferroelectric behaviour is emphasized. The chief methods for structure determination are x-ray and neutron diffraction, while the most powerful of all techniques for studying phonon properties is that of coherent inelastic neutron scattering. The most useful type of neutron spectrometer for phase transition studies, the triple axis crystal spectrometer, is discussed in detail. The history of the soft mode theory of displacive phase transitions, and its application to the antiferroelectric and 'almost ferroelectric' transitions in SrTiO 3 , provides an introduction to more recent developments in this area, including over-damped soft modes, central peaks and critical scattering, incommensurate phase transitions (e.g. K 2 SeO 4 ), amplitudons, phasons and finally solitions. The treatment throughout is descriptive and introductory, designed for graduate students

  13. Investigation of Lecturer's Chalk by x-ray Florescence and Fast Neutron Activation Techniques

    International Nuclear Information System (INIS)

    Hassan, M.F.

    2011-01-01

    Different samples of lecturer's chalk were studied, using X-ray florescence (XRF) and Fast Neutron Activation Analysis (FNAA) techniques to ensure the safety of its use. The K (X-rays) and the gamma-rays were measured, using Si(Li) and high-purity germanium (HPGe) spectrometers to detect and determine qualitatively and quantitatively the constituents of the studied samples. The concentrations of the elements (Ca and small traces of Al, Fe, Mg and Si) were measured and their presence was confirmed by gamma-ray, lifetime and/or XRF measurements.

  14. A novel x-ray circularly polarized ranging method

    Science.gov (United States)

    Song, Shi-Bin; Xu, Lu-Ping; Zhang, Hua; Gao, Na; Shen, Yang-He

    2015-05-01

    Range measurement has found multiple applications in deep space missions. With more and further deep space exploration activities happening now and in the future, the requirement for range measurement has risen. In view of the future ranging requirement, a novel x-ray polarized ranging method based on the circular polarization modulation is proposed, termed as x-ray circularly polarized ranging (XCPolR). XCPolR utilizes the circular polarization modulation to process x-ray signals and the ranging information is conveyed by the circular polarization states. As the circular polarization states present good stability in space propagation and x-ray detectors have light weight and low power consumption, XCPolR shows great potential in the long-distance range measurement and provides an option for future deep space ranging. In this paper, we present a detailed illustration of XCPolR. Firstly, the structure of the polarized ranging system is described and the signal models in the ranging process are established mathematically. Then, the main factors that affect the ranging accuracy, including the Doppler effect, the differential demodulation, and the correlation error, are analyzed theoretically. Finally, numerical simulation is carried out to evaluate the performance of XCPolR. Projects supported by the National Natural Science Foundation of China (Grant Nos. 61172138 and 61401340), the Natural Science Basic Research Plan in Shaanxi Province of China (Grant No. 2013JQ8040), the Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20130203120004), the Open Research Fund of the Academy of Satellite Application, China (Grant No. 2014 CXJJ-DH 12), the Xi’an Science and Technology Plan, China (Grant No. CXY1350(4)), the Fundamental Research Funds for the Central Universities, China (Grant Nos. 201413B, 201412B, and JB141303), and the Open Fund of Key Laboratory of Precision Navigation and Timing Technology, National Time Service Center, Chinese

  15. Vessel wall damage by X-rays and 15 MeV neutrons

    International Nuclear Information System (INIS)

    Aarnoudse, M.W.

    1979-01-01

    In two simple mucopolysaccharide systems, synovial fluid and subcutaneous connective tissue membranes, the degrading effects of 200 kVp X-rays and 15 MeV neutrons is compared. Due to the depolymerization of the mucopolysaccharides the viscosity of synovial fluid decreases and the permeability of the connective tissue membranes for saline increases after irradiation. In both systems a RBE of 0.6 has been found for fast neutrons. The atheromatous changes in the wall of elastic arteries (lipid penetration into the vessel wall and the formation of plaques consisting of large, lipid-filled foam cells) are studied in the carotid arteries of hypercholesterolemic rabbits, two months after irradiating the arteries with different doses of X-rays or neutrons. (Auth.)

  16. First examination of CASCADE-X-ray-detector and measurement of neutron-mirrorneutron-oscillation

    International Nuclear Information System (INIS)

    Boehm, B.

    2007-01-01

    The detection of X-radiation is of utmost importance for both fundamental physics and medical diagnostics. This work investigates whether or not the CASCADE detector working principle, first developed for the detection of neutrons, can be adapted for the detection of X-rays. This modular detector concept combines the use of a solid neutron or X-ray converter with the advantages of a counting gas detector. Thus, it gives the possibility to optimize efficiency, dynamics and spatial resolution independently. Firstly, it is necessary to find a suitable converter material that allows for the best possible detector efficiency. In order to do so, a mathematical model of the complete detector system was developed that yields the total efficiency for any given material. Respecting technical constraints, gold and gadolinium showed to be favorable choices. Based on these theoretical considerations a prototype of a CASCADE X-ray detector was built, and measurements for the determination of this detector's efficiency were conducted. In the second part of this work a CASCADE neutron detector was used to conduct the first measurement the neutron-mirrorneutron oscillation time. Mirrormatter was proposed in 1956 by Lee and Yang to allow for symmetry in the description of the universe despite the existence of parity violation. By using neutrons it was possible to determine a lower limit for the oscillation time in this work. (orig.)

  17. Application of neutron activation and high resolution X-ray spectrometry to the development of analytical methods suitable for the assay of trace elements in biological materials. Part of a coordinated programme on comparative methods for the study of trace elements in human nutrition

    International Nuclear Information System (INIS)

    Mantel, J.

    1980-12-01

    A new method for determining trace elements in biological materials by instrumental neutron activation analysis (INAA) has been investigated. This method is based on the measurement of low-energy X-rays emitted by the sample after appropriate activation with thermal neutrons. The X-rays were detected by a Si(Li) diode connected to a multichannel analyser. The background in the energy region of interest was reduced by means of an electromagnet which deflects high-energy beta-particles away from the detector. This method of measurement has been evaluated by application to a number of different biological reference materials. The use of the electromagnet for background reduction was shown to be extremely effective for several radionuclides that are common sources of disturbance in INAA. For 32 P the background was only 0.8% of its original value. For real samples the background reduction depends somewhat on the matrix and therefore varies from one material to another. Practical detection limits for typical biological materials were derived for 18 different trace elements. The use of a perspex absorber was also considered as an alternative to magnetic deflection of the beta rays. In practice, magnetic deflection is preferable for the lower-energy X-ray emitters such as the activation products of Co, Cr, Cu and Zn

  18. Neutron Radiation Shielding For The NIF Streaked X-Ray Detector (SXD) Diagnostic

    International Nuclear Information System (INIS)

    Song, P; Holder, J; Young, B; Kalantar, D; Eder, D; Kimbrough, J

    2006-01-01

    The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) is preparing for the National Ignition Campaign (NIC) scheduled in 2010. The NIC is comprised of several ''tuning'' physics subcampaigns leading up to a demonstration of Inertial Confinement Fusion (ICF) ignition. In some of these experiments, time-resolved x-ray imaging of the imploding capsule may be required to measure capsule trajectory (shock timing) or x-ray ''bang-time''. A capsule fueled with pure tritium (T) instead of a deutriun-tritium (DT) mixture is thought to offer useful physics surrogacy, with reduced yields of up to 5e14 neutrons. These measurements will require the use of the NIF streak x-ray detector (SXD). The resulting prompt neutron fluence at the planned SXD location (∼1.7 m from the target) would be ∼1.4e9/cm 2 . Previous measurements suggest the onset of significant background at a neutron fluence of ∼ 1e8/cm 2 . The radiation damage and operational upsets which starts at ∼1e8 rad-Si/sec must be factored into an integrated experimental campaign plan. Monte Carlo analyses were performed to predict the neutron and gamma/x-ray fluences and radiation doses for the proposed diagnostic configuration. A possible shielding configuration is proposed to mitigate radiation effects. The primary component of this shielding is an 80 cm thickness of Polyethylene (PE) between target chamber center (TCC) and the SXD diagnostic. Additionally, 6-8 cm of PE around the detector provide from the large number of neutrons that scatter off the inside of the target chamber. This proposed shielding configuration reduces the high-energy neutron fluence at the SXD by approximately a factor ∼50

  19. Neutron Radiation Shielding For The NIF Streaked X-Ray Detector (SXD) Diagnostic

    Energy Technology Data Exchange (ETDEWEB)

    Song, P; Holder, J; Young, B; Kalantar, D; Eder, D; Kimbrough, J

    2006-11-02

    The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) is preparing for the National Ignition Campaign (NIC) scheduled in 2010. The NIC is comprised of several ''tuning'' physics subcampaigns leading up to a demonstration of Inertial Confinement Fusion (ICF) ignition. In some of these experiments, time-resolved x-ray imaging of the imploding capsule may be required to measure capsule trajectory (shock timing) or x-ray ''bang-time''. A capsule fueled with pure tritium (T) instead of a deutriun-tritium (DT) mixture is thought to offer useful physics surrogacy, with reduced yields of up to 5e14 neutrons. These measurements will require the use of the NIF streak x-ray detector (SXD). The resulting prompt neutron fluence at the planned SXD location ({approx}1.7 m from the target) would be {approx}1.4e9/cm{sup 2}. Previous measurements suggest the onset of significant background at a neutron fluence of {approx} 1e8/cm{sup 2}. The radiation damage and operational upsets which starts at {approx}1e8 rad-Si/sec must be factored into an integrated experimental campaign plan. Monte Carlo analyses were performed to predict the neutron and gamma/x-ray fluences and radiation doses for the proposed diagnostic configuration. A possible shielding configuration is proposed to mitigate radiation effects. The primary component of this shielding is an 80 cm thickness of Polyethylene (PE) between target chamber center (TCC) and the SXD diagnostic. Additionally, 6-8 cm of PE around the detector provide from the large number of neutrons that scatter off the inside of the target chamber. This proposed shielding configuration reduces the high-energy neutron fluence at the SXD by approximately a factor {approx}50.

  20. Comparison of neutron and high-energy X-ray dual-beam radiography for air cargo inspection

    International Nuclear Information System (INIS)

    Liu, Y.; Sowerby, B.D.; Tickner, J.R.

    2008-01-01

    Dual-beam radiography techniques utilising various combinations of high-energy X-rays and neutrons are attractive for screening bulk cargo for contraband such as narcotics and explosives. Dual-beam radiography is an important enhancement to conventional single-beam X-ray radiography systems in that it provides additional information on the composition of the object being imaged. By comparing the attenuations of transmitted dual high-energy beams, it is possible to build a 2D image, colour coded to indicate material. Only high-energy X-rays, gamma-rays and neutrons have the required penetration to screen cargo containers. This paper reviews recent developments and applications of dual-beam radiography for air cargo inspection. These developments include dual high-energy X-ray techniques as well as fast neutron and gamma-ray (or X-ray) radiography systems. High-energy X-ray systems have the advantage of generally better penetration than neutron systems, depending on the material being interrogated. However, neutron systems have the advantage of much better sensitivity to material composition compared to dual high-energy X-ray techniques. In particular, fast neutron radiography offers the potential to discriminate between various classes of organic material, unlike dual energy X-ray techniques that realistically only offer the ability to discriminate between organic and metal objects

  1. Structural characterization of cellulosic materials using x-ray and neutron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Penttila, P.

    2013-11-01

    Cellulosic biomass can be used as a feedstock for sustainable production of biofuels and various other products. A complete utilization of the raw material requires understanding on its structural aspects and their role in the various processes. In this thesis, x-ray and neutron scattering methods were applied to study the structure of various cellulosic materials and how they are affected in different processes. The obtained results were reviewed in the context of a model for the cellulose nanostructure. The dimensions of cellulose crystallites and the crystallinity were determined with wide-angle x-ray scattering (WAXS), whereas the nanoscale fibrillar structure of cellulose was characterized with small-angle x-ray and neutron scattering (SAXS and SANS). The properties determined with the small-angle scattering methods included specific surface areas and distances characteristic of the packing of cellulose microfibrils. Also other physical characterization methods, such as x-ray microtomography, infrared spectroscopy, and solid-state NMR were utilized in this work. In the analysis of the results, a comprehensive understanding of the structural changes throughout a range of length scales was aimed at. Pretreatment of birch sawdust by pressurized hot water extraction was observed to increase the crystal width of cellulose, as determined with WAXS, even though the cellulose crystallinity was slightly decreased. A denser packing of microfibrils caused by the removal of hemicelluloses and lignin in the extraction was evidenced by SAXS. This resulted in the opening of new pores between the microfibril bundles and an increase of the specific surface area. Enzymatic hydrolysis of microcrystalline cellulose (MCC) did not lead to differences in the average crystallinity or crystal size of the hydrolysis residues, which was explained to be caused by limitations due to the large size of the enzymes as compared to the pores inside the fibril aggregates. The SAXS intensities

  2. Modified X-ray method of a study of duodenum

    Energy Technology Data Exchange (ETDEWEB)

    Korolyuk, I.P.; Bugakov, V.M.; Shinkin, V.M.

    A modified X-ray examination of duodenum under hypotension conditions is described. In comparison with the existing method, the above-mentioned modification allows one to investigate the duodenum by using double contrast - the high-concentrated barium suspension and the gas, formed after the gasificated powder dose. 327 patients have been examined by the given method, 126 of them have been diagnosed to suffer from inflammatory diseases of the stomach and the duodenum, 22 of them suffering from the duodenum peptic ulcer, 107 of them - pancreatitis, 48-cholelithiasis, 24 - the tumor of the pancreatoduodenum zone. 65 patients have been operated on. Roentgenomorphologic comparisons have been carried out for 66 patients suffering from inflammatory deseases of the duodenum. Duodenum visualization of 283 patients is found to be good and satisfactory. The given method may be used under any conditions, including polyclinics, due to the sparing nature.

  3. Determinations of silicon and phosphorus in rice planted on a district of high incidence of amyotrophic lateral sclerosis by neutron activation and X-ray fluorescence analyses

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Ishikawa, Teruumi; Kusakabe, Toshio; Katsurayama, Kousuke; Iwata, Shiro.

    1989-01-01

    Silicon and phosphorus contents in polished and unpolished rice planted on a district of high incidence of amyotrophic lateral sclerosis (ALS) have been determined by neutron activation and X-ray fluorescence methods, and compared with those from control areas. In the neutron activation analysis, β-ray spectra of 32 P produced by the 31 P(n, γ) 32 P reaction on polished and unpolished rice were measured with a low background β-ray spectrometer. In the X-ray fluorescence analysis, characteristic X-ray were analyzed with a wavelength dispersive X-ray fluorescence spectrometer. Silicon contents in polished and unpolished rice from the ALS area are 42 μg.g -1 and 370 μg.g -1 , respectively, and the corresponding phosphorus contents are 1210 μg.g -1 , and 3370 μg.g -1 , respectively. The data for ALS area are equal to those for the control area within atandard deviation. (author)

  4. Laser-driven x-ray and neutron source development for industrial applications of plasma accelerators

    Science.gov (United States)

    Brenner, C. M.; Mirfayzi, S. R.; Rusby, D. R.; Armstrong, C.; Alejo, A.; Wilson, L. A.; Clarke, R.; Ahmed, H.; Butler, N. M. H.; Haddock, D.; Higginson, A.; McClymont, A.; Murphy, C.; Notley, M.; Oliver, P.; Allott, R.; Hernandez-Gomez, C.; Kar, S.; McKenna, P.; Neely, D.

    2016-01-01

    Pulsed beams of energetic x-rays and neutrons from intense laser interactions with solid foils are promising for applications where bright, small emission area sources, capable of multi-modal delivery are ideal. Possible end users of laser-driven multi-modal sources are those requiring advanced non-destructive inspection techniques in industry sectors of high value commerce such as aerospace, nuclear and advanced manufacturing. We report on experimental work that demonstrates multi-modal operation of high power laser-solid interactions for neutron and x-ray beam generation. Measurements and Monte Carlo radiation transport simulations show that neutron yield is increased by a factor ~2 when a 1 mm copper foil is placed behind a 2 mm lithium foil, compared to using a 2 cm block of lithium only. We explore x-ray generation with a 10 picosecond drive pulse in order to tailor the spectral content for radiography with medium density alloy metals. The impact of using  >1 ps pulse duration on laser-accelerated electron beam generation and transport is discussed alongside the optimisation of subsequent bremsstrahlung emission in thin, high atomic number target foils. X-ray spectra are deconvolved from spectrometer measurements and simulation data generated using the GEANT4 Monte Carlo code. We also demonstrate the unique capability of laser-driven x-rays in being able to deliver single pulse high spatial resolution projection imaging of thick metallic objects. Active detector radiographic imaging of industrially relevant sample objects with a 10 ps drive pulse is presented for the first time, demonstrating that features of 200 μm size are resolved when projected at high magnification.

  5. Laser-driven x-ray and neutron source development for industrial applications of plasma accelerators

    International Nuclear Information System (INIS)

    Brenner, C M; Rusby, D R; Armstrong, C; Wilson, L A; Clarke, R; Haddock, D; McClymont, A; Notley, M; Oliver, P; Allott, R; Hernandez-Gomez, C; Neely, D; Mirfayzi, S R; Alejo, A; Ahmed, H; Kar, S; Butler, N M H; Higginson, A; McKenna, P; Murphy, C

    2016-01-01

    Pulsed beams of energetic x-rays and neutrons from intense laser interactions with solid foils are promising for applications where bright, small emission area sources, capable of multi-modal delivery are ideal. Possible end users of laser-driven multi-modal sources are those requiring advanced non-destructive inspection techniques in industry sectors of high value commerce such as aerospace, nuclear and advanced manufacturing. We report on experimental work that demonstrates multi-modal operation of high power laser-solid interactions for neutron and x-ray beam generation. Measurements and Monte Carlo radiation transport simulations show that neutron yield is increased by a factor ∼2 when a 1 mm copper foil is placed behind a 2 mm lithium foil, compared to using a 2 cm block of lithium only. We explore x-ray generation with a 10 picosecond drive pulse in order to tailor the spectral content for radiography with medium density alloy metals. The impact of using  >1 ps pulse duration on laser-accelerated electron beam generation and transport is discussed alongside the optimisation of subsequent bremsstrahlung emission in thin, high atomic number target foils. X-ray spectra are deconvolved from spectrometer measurements and simulation data generated using the GEANT4 Monte Carlo code. We also demonstrate the unique capability of laser-driven x-rays in being able to deliver single pulse high spatial resolution projection imaging of thick metallic objects. Active detector radiographic imaging of industrially relevant sample objects with a 10 ps drive pulse is presented for the first time, demonstrating that features of 200 μm size are resolved when projected at high magnification. (paper)

  6. X-ray and synchrotron methods in studies of cultural heritage sites

    Energy Technology Data Exchange (ETDEWEB)

    Koval’chuk, M. V.; Yatsishina, E. B.; Blagov, A. E.; Tereshchenko, E. Yu., E-mail: elenatereschenko@yandex.ru; Prosekov, P. A.; Dyakova, Yu. A. [National Research Centre “Kurchatov Institute” (Russian Federation)

    2016-09-15

    X-ray and synchrotron methods that are most widely used in studies of cultural heritage objects (including archaeological sites)—X-ray diffraction analysis, X-ray spectroscopy, and visualization techniques— have been considered. The reported examples show high efficiency and informativeness of natural science studies when solving most diverse problems of archaeology, history, the study of art, museology, etc.

  7. X-ray and synchrotron methods in studies of cultural heritage sites

    International Nuclear Information System (INIS)

    Koval’chuk, M. V.; Yatsishina, E. B.; Blagov, A. E.; Tereshchenko, E. Yu.; Prosekov, P. A.; Dyakova, Yu. A.

    2016-01-01

    X-ray and synchrotron methods that are most widely used in studies of cultural heritage objects (including archaeological sites)—X-ray diffraction analysis, X-ray spectroscopy, and visualization techniques— have been considered. The reported examples show high efficiency and informativeness of natural science studies when solving most diverse problems of archaeology, history, the study of art, museology, etc.

  8. A neutron survey of a 25 MV x-ray clinical linac treatment room

    International Nuclear Information System (INIS)

    Price, Kenneth W.; Holeman, George R.; Nath, Ravinder

    1978-01-01

    Neutron production in high energy x-ray radiotherapy machines results in unnecessary dose to patients and has been of recent interest to private and Federal agencies. An activation technique has been used to measure fast and thermal neutron fluxes in the high energy x-ray beam, and at radial distances of 1 and 2 meters from the beam axis of the 25 MV Sagittaire Linear Accelerator located at the Yale-New Haven Hospital's Cancer Therapy Center. Phosphorous pentoxide activation detectors were used to monitor the thermal flux and the fast neutron flux above 0.7 MeV neutron energy. Unlike other techniques for measuring neutrons, this detector has been shown to be insensitive to high energy photon interference at the photon dose rates present in the beam. Neutron spectra at various distances from the accelerator target were computed for the treatment room geometry using the Morse Monte Carlo Code (R.C. McCall, SLAC, Personal Communication). Normalization of these spectra provided the means by which the activation products measured in the phosphorous were converted to fast neutron fluxes. Dose equivalent conversion factors were applied to each energy of the calculated neutron spectra and integrated, resulting in fast neutron flux to dose equivalent conversion factors at various locations in the treatment room. Fast neutron dose equivalent was found to maximize in the photon beam, (0.005 - .007 neutron Rem/photon Rad) and decrease with distance thereafter. Thermal neutron dose equivalent was found to be essentially constant through- out the treatment room (∼ 3.35x10 -5 neutron Rem/ photon Rad). (author)

  9. Effect of x rays and neutrons on repair and regeneration in the rat spinal cord

    International Nuclear Information System (INIS)

    van der Kogel, A.J.; Sissingh, H.A.; Zoetelief, J.

    1982-01-01

    Clinical and experimental results of neutron irradiation have shown higher RBE values for the central nervous system (CNS) than for most other normal tissues. This is because of a considerable impairment of a large capacity of the CNS to repair subeffective damage induced by low LET radiation. Decreasing the dose per fraction of X rays increases the CNS tolerance significantly; this has no effect for neutrons. In the cervical spinal cord and the brain, two types of delayed damage can be described, so-called early and late. Different target cells are assumed to be involved, oligodendroglial cells in the early, and vascular endothelim in the late type. In the lumbar cord, the main lesion is nerve root necrosis, with the Schwann cell as the most probable target. These target cells show differences in response to X rays and neutrons, resulting in different RBE values. The highest RBE is obtained for cervical white matter necrosis. In addition to cellular repair of subeffective damage, long-term tissue regeneration is observed in the spinal cord, beginning at different times for the various types of damage. With neutrons, the rate of long-term regeneration is at least similar, or even more pronounced than for X rays

  10. Effect of x rays and neutrons on repair and regeneration in the rat spinal cord

    International Nuclear Information System (INIS)

    Van der Kogel, A.J.; Sissingh, H.A.; Zoetelief, J.

    1982-01-01

    Clinical and experimental results of neutron irradiation have shown higher RBE values for the central nervous system (CNS) than for most other normal tissues. This is because of a considerable impairment of the large capacity of the CNS to repair subeffective damage induced by low LET radiation. Decreasing the dose per fraction of X rays increases the CNS tolerance significantly; this has no effect for neutrons. In the cervical spinal cord and the brain, two types of delayed damage can be described, so-called early and late. Different target cells are assumed to be involved, oligodendroglial cells in the early, and vascular endothelium in the late type. In the lumbar cord, the main lesion is nerve root necrosis, with the Schwann cell as the most probable target. These target cells show differences in response to X rays and neutrons, resulting in different RBE values. The highest RBE is obtained for cervical white matter necrosis. In addition to cellular repair of subeffective damage, long-term tissue regeneration is observed in the spinal cord, beginning at different times for the various types of damage. With neutrons, the rate of long-term regeneration is at least similar, or even more pronounced than for X rays

  11. Determinations of elements in pepperbush standard reference material by neutron activation and X-ray fluorescence analyses

    International Nuclear Information System (INIS)

    Mizumoto, Yoshihiko; Okada, Takayuki; Tatsumi, Toshiya; Kusakabe, Toshio; Katsurayama, Kousuke; Iwata, Shiro.

    1988-01-01

    Elemental contents in Pepperbush standard reference material have been determined by neutron activation and X-ray fluorescence analyses. The standard samples of orchard leaves, tomato leaves, pine needles and Kale are used for the experiment. In the neutron activation analysis, gamma-ray spectra of nuclei produced by (n,γ) reaction on Pepperbush and standard samples are measured with Ge detectors. In the X-ray fluorescence analysis, the samples are excited with X-rays from X-ray tube with rhodium anode, and the characteristic X-rays from samples are measured with a proportional counter or NaI(Tl) detector. From the gamma- and X-ray intensities, the elemental contents in Pepperbush are determined. As a result, the contents of seventeen elements, such as sodium, calcium, iron, etc., in Pepperbush are determined. (author)

  12. Fluid bilayer structure determination: Joint refinement in composition space using X-ray and neutron diffraction data

    Energy Technology Data Exchange (ETDEWEB)

    White, S.H. [Univ. of California, Irvine, CA (United States); Wiener, M.C. [Univ. of California, San Francisco, CA (United States)

    1994-12-31

    Experimentally-determined structural models of fluid lipid bilayers are essential for verifying molecular dynamics simulations of bilayers and for understanding the structural consequences of peptide interactions. The extreme thermal motion of bilayers precludes the possibility of atomic-level structural models. Defining {open_quote}the structure{close_quote} of a bilayer as the time-averaged transbilayer distribution of the water and the principal lipid structural groups such as the carbonyls and double-bonds (quasimolecular fragments), one can represent the bilayer structure as a sum of Gaussian functions referred to collectively as the quasimolecular structure. One method of determining the structure is by neutron diffraction combined with exhaustive specific deuteration. This method is impractical because of the expense of the chemical syntheses and the limited amount of neutron beam time currently available. We have therefore developed the composition space refinement method for combining X-ray and minimal neutron diffraction data to arrive at remarkably detailed and accurate structures of fluid bilayers. The composition space representation of the bilayer describes the probability of occupancy per unit length across the width of the bilayer of each quasimolecular component and permits the joint refinement of X-ray and neutron lamellar diffraction data by means of a single quasimolecular structure that is fitted simultaneously to both data sets. Scaling of each component by the appropriate neutron or X-ray scattering length maps the composition-space profile to the appropriate scattering length space for comparison to experimental data. The difficulty with the method is that fluid bilayer structures are generally only marginally determined by the experimental data. This means that the space of possible solutions must be extensively explored in conjunction with a thorough analysis of errors.

  13. Fluid bilayer structure determination: Joint refinement in composition space using X-ray and neutron diffraction data

    International Nuclear Information System (INIS)

    White, S.H.; Wiener, M.C.

    1994-01-01

    Experimentally-determined structural models of fluid lipid bilayers are essential for verifying molecular dynamics simulations of bilayers and for understanding the structural consequences of peptide interactions. The extreme thermal motion of bilayers precludes the possibility of atomic-level structural models. Defining open-quote the structure close-quote of a bilayer as the time-averaged transbilayer distribution of the water and the principal lipid structural groups such as the carbonyls and double-bonds (quasimolecular fragments), one can represent the bilayer structure as a sum of Gaussian functions referred to collectively as the quasimolecular structure. One method of determining the structure is by neutron diffraction combined with exhaustive specific deuteration. This method is impractical because of the expense of the chemical syntheses and the limited amount of neutron beam time currently available. We have therefore developed the composition space refinement method for combining X-ray and minimal neutron diffraction data to arrive at remarkably detailed and accurate structures of fluid bilayers. The composition space representation of the bilayer describes the probability of occupancy per unit length across the width of the bilayer of each quasimolecular component and permits the joint refinement of X-ray and neutron lamellar diffraction data by means of a single quasimolecular structure that is fitted simultaneously to both data sets. Scaling of each component by the appropriate neutron or X-ray scattering length maps the composition-space profile to the appropriate scattering length space for comparison to experimental data. The difficulty with the method is that fluid bilayer structures are generally only marginally determined by the experimental data. This means that the space of possible solutions must be extensively explored in conjunction with a thorough analysis of errors

  14. Precision test method by x-ray absorbent clay

    International Nuclear Information System (INIS)

    Nakadai, Toru; Matsukawa, Hideyuki; Sekita, Jun-ichiro; Murakoshi, Atsushi.

    1982-01-01

    In X-ray penetration photography of such as welds with reinforcing metal and castings of complex shape, the X-ray absorbent clay developed to eliminate various disadvantages of the conventional absorbents was further studied for better application. The results of the usage are as follows. Because the X-ray absorbent is clay, it is flexible in form, and gives good adhesion to test objects. In the welds and castings mentioned, it is effective for reducing the scattered ray, accordingly, it results in superior images. The following matters are described: contrast in radiographs, the required conditions for X-ray absorbents in general, the properties of the absorbent (absorption coefficient, consistency, density), improvement in radiographs by means of the X-ray absorbent clay (wall thickness compensation, masking, the application together with narrow-field irradiation photography). (Mori, K.)

  15. Low-angle polarized neutron and X-ray scattering from magnetic nanolayers and nanostructures

    CERN Document Server

    Paul, Amitesh

    2017-01-01

    This research monograph presents the latest results related to the characterization of low dimensional systems. Low-angle polarized neutron scattering and X-ray scattering at grazing incidence are used as the two main techniques to explore various physical phenomena of these systems. Special focus is put on systems like thin film transition metal and rare-earth layers, oxide heterostructures, hybrid systems, self-assembled nanostructures and self-diffusion.  Readers will gain in-depth knowledge about the usage of specular scattering and off-specular scattering techniques. Investigation of in-plane and out-of-plane structures and magnetism with vector magnetometric information is illustrated comprehensively. The book caters to a wide audience working in the field of nano-dimensional magnetic systems and the neutron and X-ray reflectometry community in particular.

  16. X-ray and neutron diffraction and molecular dynamics simulation of molten lithium and rubidium nitrates

    International Nuclear Information System (INIS)

    Yamaguchi, Toshio; Okada, Isao; Ohtaki, Hitoshi; Mikami, Masuhiro; Kawamura, Kazutaka

    1986-01-01

    Molecular dynamics simulations have been performed for lithium and rubidium nitrate melts at 550 and 600K, respectively, together with X-ray and neutron diffraction experiments. Simple Coulomb pair potentials with Born-type repulsions have been adopted in the simulations with a rigid body model for the nitrate ion. Structure functions derived from the X-ray and neutron experiments are well reproduced by the simulations, from which the three-dimensional cation distribution around the nitrate ion has been revealed. The self-diffusion coefficients, the velocity autocorrelation functions and the self-exchange velocities of lithium, rubidium and nitrate ions have been calculated. Anisotropic motion of nitrate ions has been found and is discussed on the basis of the structure of the melts. (author)

  17. Neutron stars as X-ray burst sources. II. Burst energy histograms and why they burst

    International Nuclear Information System (INIS)

    Baan, W.A.

    1979-01-01

    In this work we explore some of the implications of a model for X-ray burst sources where bursts are caused by Kruskal-Schwarzschild instabilities at the magnetopause of an accreting and rotating neutron star. A number of simplifying assumptions are made in order to test the model using observed burst-energy histograms for the rapid burster MXB 1730--335. The predicted histograms have a correct general shape, but it appears that other effects are important as well, and that mode competition, for instance, may suppress the histograms at high burst energies. An explanation is ventured for the enhancement in the histogram at the highest burst energies, which produces the bimodal shape in high accretion rate histograms. Quantitative criteria are given for deciding when accreting neutron stars are steady sources or burst sources, and these criteria are tested using the X-ray pulsars

  18. Ultra-High Field Magnets for X-Ray and Neutron Scattering using High Temperature Superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Winn, Barry L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Broholm, C. [Johns Hopkins Univ., Baltimore, MD (United States); Bird, M. [Florida State Univ., Tallahassee, FL (United States). National High Magnetic Field Lab. (MagLab); Breneman, Bruce C. [General Atomics, San Diego, CA (United States); Coffey, Michael [Cryomagnetics, Oak Ridge, TN (United States); Cutler, Roy I. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Duckworth, Robert C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Erwin, R. [National Inst. of Standards and Technology (NIST), Gaithersburg, MD (United States); Hahn, Seungyong [Florida State Univ., Tallahassee, FL (United States). National High Magnetic Field Lab. (MagLab); Hernandez, Yamali [National Inst. of Standards and Technology (NIST), Gaithersburg, MD (United States); Herwig, Kenneth W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Holland, Leo D. [General Atomics, San Diego, CA (United States); Lonergan, Kevin M. [Oxford Instruments, Abingdon (United Kingdom); Melhem, Ziad [Oxford Instruments, Abingdon (United Kingdom); Minter, Stephen J. [Cryomagnetics, Oak Ridge, TN (United States); Nelson, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Paranthaman, M. Parans [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Pierce, Josh [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ruff, Jacob [Cornell Univ., Ithaca, NY (United States); Shen, Tengming [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherline, Todd E. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Smeibidl, Peter G. [Helmholtz-Zentrum Berlin (HZB), (Germany); Tennant, David [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); van der Laan, Danko [Advanced Conductor Technologies, LLC, Boulder, CO (United States); Wahle, Robert J. [Helmholtz-Zentrum Berlin (HZB), (Germany); Zhang, Yifei [SuperPower, Inc., Schenectady, NY (United States)

    2017-01-01

    X-ray and neutron scattering techniques are capable of acquiring information about the structure and dynamics of quantum matter. However, the high-field magnet systems currently available at x-ray and neutron scattering facilities in the United States are limited to fields of 16 tesla (T) at maximum, which precludes applications that require and/or study ultra-high field states of matter. This gap in capability—and the need to address it—is a central conclusion of the 2005 National Academy of Sciences report by the Committee on Opportunities in High Magnetic Field Science. To address this gap, we propose a magnet development program that would more than double the field range accessible to scattering experiments. With the development and use of new ultra-high field–magnets, the program would bring into view new worlds of quantum matter with profound impacts on our understanding of advanced electronic materials.

  19. Non-Quiescent X-ray Emission from Neutron Stars and Black Holes

    Energy Technology Data Exchange (ETDEWEB)

    Tournear, Derek M

    2003-08-18

    X-ray astronomy began with the detection of the persistent source Scorpius X-1. Shortly afterwards, sources were detected that were variable. Centaurus X-2, was determined to be an X-ray transient, having a quiescent state, and a state that was much brighter. As X-ray astronomy progressed, classifications of transient sources developed. One class of sources, believed to be neutron stars, undergo extreme luminosity transitions lasting a few seconds. These outbursts are believed to be thermonuclear explosions occurring on the surface of neutron stars (type I X-ray bursts). Other sources undergo luminosity changes that cannot be explained by thermonuclear burning and last for days to months. These sources are soft X-ray transients (SXTs) and are believed to be the result of instabilities in the accretion of matter onto either a neutron star or black hole. Type I X-ray bursts provide a tool for probing the surfaces of neutron stars. Requiring a surface for the burning has led authors to use the presence of X-ray bursts to rule out the existence of a black hole (where an event horizon exists not a surface) for systems which exhibit type I X-ray bursts. Distinguishing between neutron stars and black holes has been a problem for decades. Narayan and Heyl have developed a theoretical framework to convert suitable upper limits on type I X-ray bursts from accreting black hole candidates (BHCs) into evidence for an event horizon. We survey 2101.2 ks of data from the USA X-ray timing experiment and 5142 ks of data from the Rossi X-ray Timing Explorer (RXTE) experiment to obtain the first formal constraint of this type. 1122 ks of neutron star data yield a population averaged mean burst rate of 1.7 {+-} 0.4 x 10{sup -5} bursts s{sup -1}, while 6081 ks of BHC data yield a 95% confidence level upper limit of 4.9 x 10{sup -7} bursts s{sup -1}. Applying the framework of Narayan and Heyl we calculate regions of luminosity where the neutron stars are expected to burst and the BHCs

  20. X-ray and neutron small-angle scattering studies of human serum lipoproteins

    International Nuclear Information System (INIS)

    Luzzati, V.; Tardieu, A.; Mateu, L.; Sardet, C.; Stuhrmann, H.B.; Aggerbeck, L.; Scanu, A.M.

    1976-01-01

    The paper describes an extended x-ray study of two types of human serum lipoproteins and a neutron study of one of them. The results are similar and to some extent complementary. Serum lipoproteins provide an excellent illustration of the wealth of information that can be obtained by a small-angle scattering approach to the structure of particles with non-uniform density distribution, by using solvents of variable density

  1. Secondary extinction in cylindrical and spherical crystals for X-ray and neutron diffraction

    International Nuclear Information System (INIS)

    Hu Huachen; Li Zhaohuan; Yang Bin; Shen Caiwan

    2001-01-01

    The distribution of the reflection power ratio for a neutron or x-ray diffracted from a cylindrical crystal immersed in an homogenous incident beam is obtained by the numerical solution of the transfer equations for the first time. The profile well reflects all the physical properties of the absorption and extinction behaviour in the crystals. A systematic investigation of the secondary extinction for cylindrical and spherical crystals was carried out based on these results

  2. Study of humic acids by small-angle X-ray and neutron scattering

    International Nuclear Information System (INIS)

    Timchenko, A.; Trubetskaya, O.; Kihara, H.

    1999-01-01

    Humic acids are an important component of natural ecological system and represent a polydisperse complex of natural biopolymers with molecular masses from several to hundreds kilodaltons. They are both a source of organic compounds and a protector against anthropogenic pollutions of biosphere. The aim of the report is to underline some possibilities of small-angle X-ray and neutron scattering to study HA and their fractions. (author)

  3. Spermatogenesis in adult rhesus monkeys following irradiation with X-rays or fission neutrons

    International Nuclear Information System (INIS)

    Rooij, D.G. de; Sonneveld, P.; Bekkum, D.W. van

    A group of male rhesus monkeys was exposed to total body irradiation followed by autologous bone marrow transplantation. The animals were irradiated in the period between 1965 and 1976 and received a dose of 8.5 Gy of X-rays (300 KVP) or 3.6 Gy of 1 MeV fission neutrons. Of this group, a total of 11 male monkeys proved to be evaluable for studying the effects of irradiation on spermatogenesis. (Auth.)

  4. Application of instrumental neutron activation analysis and X-ray fluorescence analysis in art pieces investigation

    International Nuclear Information System (INIS)

    Panczyk, E.; Kierzek, J.; Walis, L.; Ligeza, M.

    1996-01-01

    The application of instrumental neutron activation analysis have been shown for the trace element identification in dyes of old painting and other art objects. The recognition of their composition is a important measure for attribution. Also the X-ray fluorescence analysis has been frequently used for examination of art objects. The age determination of the old chinese porcelain is a good example described in the paper. 20 refs, 4 figs

  5. A neutron-X-ray, NMR and calorimetric study of glassy Probucol synthesized using containerless techniques

    International Nuclear Information System (INIS)

    Weber, J.K.R.; Benmore, C.J.; Tailor, A.N.; Tumber, S.K.; Neuefeind, J.; Cherry, B.; Yarger, J.L.; Mou, Q.; Weber, W.; Byrn, S.R.

    2013-01-01

    Highlights: • Acoustic levitation was used to make phase-pure glassy forms of pharmaceutical compounds. • Neutrons, X-rays and NMR were used to characterize the glasses. • The glass comprised of slightly distorted molecules packed in a random network. • Potential for new drug synthesis routes is discussed. - Abstract: Acoustic levitation was used to trap 1–3 mm diameter drops of Probucol and other pharmaceutical materials in containerless conditions. Samples were studied in situ using X-ray diffraction and ex situ using neutron diffraction, NMR and DSC techniques. The materials were brought into non-equilibrium states by supersaturating solutions or by supercooling melts. The glass transition and crystallization temperatures of glassy Probucol were 29 ± 1 and 71 ± 1 °C respectively. The glassy form was stable with a shelf life of at least 8 months. A neutron/X-ray difference function of the glass showed that while molecular sub-groups remain rigid, many of the hydrogen correlations observed in the crystal become smeared out in the disordered material. The glass is principally comprised of slightly distorted Form I Probucol molecules with disordered packing rather than large changes in the individual molecular structure. Avoiding surface contact-induced nucleation provided access to highly non-equilibrium phases and enabled synthesis of phase-pure glasses

  6. A neutron-X-ray, NMR and calorimetric study of glassy Probucol synthesized using containerless techniques

    Energy Technology Data Exchange (ETDEWEB)

    Weber, J.K.R., E-mail: rweber@anl.gov [Materials Development, Inc., Arlington Heights, IL 60004 (United States); Argonne National Laboratory, Argonne, IL 60439 (United States); Benmore, C.J. [Argonne National Laboratory, Argonne, IL 60439 (United States); Department of Physics, Arizona State University, AZ 85287 (United States); Tailor, A.N.; Tumber, S.K. [Materials Development, Inc., Arlington Heights, IL 60004 (United States); Neuefeind, J. [Oak Ridge National Laboratory, Oak Ridge, TN 37831 (United States); Cherry, B. [Magnetic Resonance Research Center, Arizona State University, AZ 85287 (United States); Department of Chemistry and Biochemistry, Arizona State University, AZ 85287 (United States); Yarger, J.L. [Department of Physics, Arizona State University, AZ 85287 (United States); Magnetic Resonance Research Center, Arizona State University, AZ 85287 (United States); Department of Chemistry and Biochemistry, Arizona State University, AZ 85287 (United States); Mou, Q. [Magnetic Resonance Research Center, Arizona State University, AZ 85287 (United States); Department of Chemistry and Biochemistry, Arizona State University, AZ 85287 (United States); Weber, W. [Department of Physics, Arizona State University, AZ 85287 (United States); Department of Chemistry and Biochemistry, Arizona State University, AZ 85287 (United States); Byrn, S.R. [Department of Industrial and Physical Pharmacy, Purdue University, IN 47907 (United States)

    2013-10-16

    Highlights: • Acoustic levitation was used to make phase-pure glassy forms of pharmaceutical compounds. • Neutrons, X-rays and NMR were used to characterize the glasses. • The glass comprised of slightly distorted molecules packed in a random network. • Potential for new drug synthesis routes is discussed. - Abstract: Acoustic levitation was used to trap 1–3 mm diameter drops of Probucol and other pharmaceutical materials in containerless conditions. Samples were studied in situ using X-ray diffraction and ex situ using neutron diffraction, NMR and DSC techniques. The materials were brought into non-equilibrium states by supersaturating solutions or by supercooling melts. The glass transition and crystallization temperatures of glassy Probucol were 29 ± 1 and 71 ± 1 °C respectively. The glassy form was stable with a shelf life of at least 8 months. A neutron/X-ray difference function of the glass showed that while molecular sub-groups remain rigid, many of the hydrogen correlations observed in the crystal become smeared out in the disordered material. The glass is principally comprised of slightly distorted Form I Probucol molecules with disordered packing rather than large changes in the individual molecular structure. Avoiding surface contact-induced nucleation provided access to highly non-equilibrium phases and enabled synthesis of phase-pure glasses.

  7. Sub-atomic resolution X-ray crystallography and neutron crystallography: promise, challenges and potential.

    Science.gov (United States)

    Blakeley, Matthew P; Hasnain, Samar S; Antonyuk, Svetlana V

    2015-07-01

    The International Year of Crystallography saw the number of macromolecular structures deposited in the Protein Data Bank cross the 100000 mark, with more than 90000 of these provided by X-ray crystallography. The number of X-ray structures determined to sub-atomic resolution (i.e. ≤1 Å) has passed 600 and this is likely to continue to grow rapidly with diffraction-limited synchrotron radiation sources such as MAX-IV (Sweden) and Sirius (Brazil) under construction. A dozen X-ray structures have been deposited to ultra-high resolution (i.e. ≤0.7 Å), for which precise electron density can be exploited to obtain charge density and provide information on the bonding character of catalytic or electron transfer sites. Although the development of neutron macromolecular crystallography over the years has been far less pronounced, and its application much less widespread, the availability of new and improved instrumentation, combined with dedicated deuteration facilities, are beginning to transform the field. Of the 83 macromolecular structures deposited with neutron diffraction data, more than half (49/83, 59%) were released since 2010. Sub-mm(3) crystals are now regularly being used for data collection, structures have been determined to atomic resolution for a few small proteins, and much larger unit-cell systems (cell edges >100 Å) are being successfully studied. While some details relating to H-atom positions are tractable with X-ray crystallography at sub-atomic resolution, the mobility of certain H atoms precludes them from being located. In addition, highly polarized H atoms and protons (H(+)) remain invisible with X-rays. Moreover, the majority of X-ray structures are determined from cryo-cooled crystals at 100 K, and, although radiation damage can be strongly controlled, especially since the advent of shutterless fast detectors, and by using limited doses and crystal translation at micro-focus beams, radiation damage can still take place. Neutron

  8. Sub-atomic resolution X-ray crystallography and neutron crystallography: promise, challenges and potential

    Directory of Open Access Journals (Sweden)

    Matthew P. Blakeley

    2015-07-01

    Full Text Available The International Year of Crystallography saw the number of macromolecular structures deposited in the Protein Data Bank cross the 100000 mark, with more than 90000 of these provided by X-ray crystallography. The number of X-ray structures determined to sub-atomic resolution (i.e. ≤1 Å has passed 600 and this is likely to continue to grow rapidly with diffraction-limited synchrotron radiation sources such as MAX-IV (Sweden and Sirius (Brazil under construction. A dozen X-ray structures have been deposited to ultra-high resolution (i.e. ≤0.7 Å, for which precise electron density can be exploited to obtain charge density and provide information on the bonding character of catalytic or electron transfer sites. Although the development of neutron macromolecular crystallography over the years has been far less pronounced, and its application much less widespread, the availability of new and improved instrumentation, combined with dedicated deuteration facilities, are beginning to transform the field. Of the 83 macromolecular structures deposited with neutron diffraction data, more than half (49/83, 59% were released since 2010. Sub-mm3 crystals are now regularly being used for data collection, structures have been determined to atomic resolution for a few small proteins, and much larger unit-cell systems (cell edges >100 Å are being successfully studied. While some details relating to H-atom positions are tractable with X-ray crystallography at sub-atomic resolution, the mobility of certain H atoms precludes them from being located. In addition, highly polarized H atoms and protons (H+ remain invisible with X-rays. Moreover, the majority of X-ray structures are determined from cryo-cooled crystals at 100 K, and, although radiation damage can be strongly controlled, especially since the advent of shutterless fast detectors, and by using limited doses and crystal translation at micro-focus beams, radiation damage can still take place

  9. Feasibility study on X-ray source with pinhole imaging method

    International Nuclear Information System (INIS)

    Qiu Rui; Li Junli

    2007-01-01

    In order to verify the feasibility of study on X-ray source with pinhole imaging method, and optimize the design of X-ray pinhole imaging system, an X-ray pinhole imaging equipment was set up. The change of image due to the change of the position and intensity of X-ray source was estimated with mathematical method and validated with experiment. The results show that the change of the spot position and gray of the spot is linearly related with the change of the position and intensity of X-ray source, so it is feasible to study X-ray source with pinhole imaging method in this application. The results provide some references for the design of X-ray pinhole imaging system. (authors)

  10. Searching for X-ray Pulsations from Neutron Stars Using NICER

    Science.gov (United States)

    Ray, Paul S.; Arzoumanian, Zaven; Gendreau, Keith C.; Bogdanov, Slavko; Bult, Peter; Chakrabarty, Deepto; Chakrabarty, Deepto; Guillot, Sebastien; Harding, Alice; Ho, Wynn C. G.; Lamb, Frederick; Mahmoodifar, Simin; Miller, Cole; Strohmayer, Tod; Wilson-Hodge, Colleen; Wolff, Michael T.; NICER Science Team Working Group on Pulsation Searches and Multiwavelength Coordination

    2018-01-01

    The Neutron Star Interior Composition Explorer (NICER) presents an exciting new capability for discovering new modulation properties of X-ray emitting neutron stars, including large area, low background, extremely precise absolute time stamps, superb low-energy response and flexible scheduling. The Pulsation Searches and Multiwavelength Coordination working group has designed a 2.5 Ms observing program to search for pulsations and characterize the modulation properties of about 30 known or suspected neutron star sources across a number of source categories. A key early goal will be to search for pulsations from millisecond pulsars that might exhibit thermal pulsations from the surface suitable for pulse profile modeling to constrain the neutron star equation of state. In addition, we will search for pulsations from transitional millisecond pulsars, isolated neutron stars, LMXBs, accretion-powered millisecond pulsars, central compact objects and other sources. We present our science plan and initial results from the first months of the NICER mission.

  11. Constraining the physics of the r-mode instability in neutron stars with X-ray and ultraviolet observations

    NARCIS (Netherlands)

    Haskell, B.; Degenaar, N.; Ho, W.C.G.

    2012-01-01

    Rapidly rotating neutron stars in low-mass X-ray binaries may be an interesting source of gravitational waves (GWs). In particular, several modes of stellar oscillation may be driven unstable by GW emission, and this can lead to a detectable signal. Here we illustrate how current X-ray and

  12. The disc-jet coupling in the neutron star X-ray binary 4U 1728-34

    NARCIS (Netherlands)

    Tudose, Valeriu; Tzioumis, Anastasios; Belloni, Tomaso; Altamirano, Diego; Linares, Manuel; Mendez, Mariano; Hiemstra, Beike

    2010-01-01

    The present radio proposal is part of a multi-wavelength campaign focused on the study of the accretion/ejection process in the neutron star X-ray binary system 4U 1728-34. Our intention is to study the behaviour of the inner part of the accretion disc as inferred from the X-ray observations of the

  13. X-ray and neutron scattering investigations of YCo sub 3 -H

    Energy Technology Data Exchange (ETDEWEB)

    Benham, M J; Bennington, S M; Ross, D K [Birmingham Univ. (UK). School of Physics and Space Research; Noreus, D [Stockholm Univ. (Sweden). Dept. of Structural Chemistry; Yamaguchi, M [Yokohoma National Univ. (Japan). Dept. of Electrical and Computer Engineering

    1989-01-01

    Various structural studies of YCo{sub 3}H(D){sub x} in the {beta}-phase (0X-ray diffraction measurements determined that the expansion of the lattice is localised to components of the structure which are related to the Laves phase, YCo{sub 2}. Neutron diffraction and inelastic neutron scattering were also used in tandem, and hydrogen occupation of a single (36i) tetrahedral site was inferred for the entire concentration range. (orig.).

  14. DNA Damage Induction and Repair Evaluated in Human Lymphocytes Irradiated with X-Rays an Neutrons

    International Nuclear Information System (INIS)

    Niedzwiedz, W.; Cebulska-Wasilewska, A.

    2000-12-01

    The objective of this study was to evaluate the kinetic of the DNA damage induction and their subsequent repair in human lymphocytes exposed to various types of radiation. PBLs cells were isolated from the whole blood of two young healthy male subjects and one skin cancer patient, and than exposed to various doses of low LET X-rays and high LET neutrons from 252 Cf source. To evaluate the DNA damage we have applied the single cell get electrophoresis technique (SCGE) also known as the comet assay. In order to estimate the repair efficiency, cells, which had been irradiated with a certain dose, were incubated at 37 o C for various periods of time (0 to 60 min). The kinetic of DNA damage recovery was investigated by an estimation of residual DNA damage persisted at cells after various times of post-irradiation incubation (5, 10, 15, 30 and 60 min). We observed an increase of the DNA damage (reported as a Tail DNA and Tail moment parameters) in linear and linear-quadratic manner, with increasing doses of X-rays and 252 Cf neutrons, respectively. Moreover, for skin cancer patient (Code 3) at whole studied dose ranges the higher level of the DNA damage was observed comparing to health subjects (Code 1 and 2), however statistically insignificant (for Tail DNA p=0.056; for Tail moment p=0.065). In case of the efficiency of the DNA damage repair it was observed that after 1 h of post-irradiation incubation the DNA damage induced with both, neutrons and X-rays had been significantly reduced (from 65% to 100 %). Furthermore, in case of skin cancer patient we observed lover repair efficiency of X-rays induced DNA damage. After irradiation with neutrons within first 30 min, the Tail DNA and Tail moment decreased of about 50%. One hour after irradiation, almost 70% of residual and new formed DNA damage was still observed. In this case, the level of unrepaired DNA damage may represent the fraction of the double strand breaks as well as more complex DNA damage (i.e.-DNA or DNA

  15. X-ray and neutron emission studies in a new Filippov type plasma focus

    Energy Technology Data Exchange (ETDEWEB)

    Babazadeh, A.R.; Banoushi, A. [Technical University of Amirkabir, Tehran (Iran, Islamic Republic of). Dept. of Physics; Roshan, M.V.; Habibi, H.; Nasiry, A.; Memarzadeh, M.; Lamehi, M.; Kiai, S.M. Sadat [Atomic Energy Organization of Iran (AEOI), Tehran (Iran, Islamic Republic of). Nuclear Fusion Research Center

    2002-03-01

    We have performed experimental comparative studies of the X-ray and neutron emission generated by the new Filippov-type plasma focus 'Dena', (90 kJ, 25 kV, 288{mu}F) in the pressure range of 0.6-1 torr. Time-integrated and time-resolved detectors, together with an X-ray pin-hole camera, along with a Be filter of 10{mu}m thickness have been used. For a working gas of neon and a at insert anode, the maximum soft and hard X-rays (SXR-HXR) yield obtained was 16 V and 1.5 V/shot over a 4{pi} solid angle, respectively, for a charging voltage range of 16-20 kV. As for the argon gas, the similar results such as 3.5 and 2 V/shot have been found, leading to a total conversion efficiency of X-ray emission of 0.09 % (for neon) and 0.03 % (for argon) of the stored energy. These efficiencies have been improved by the employment of a conic insert anode up to 0.4% and 0.1%. With deuterium puffing gas and a at insert anode, the maximum emission yield has been found to be 2.5 V for SXR and 1 V for HXR/shot which produce an ultimate emission profile width (FWHM) of 70-90 ns for X-rays and neutrons, giving rise to a maximum neutron yield of 1.2 x 10{sup 9}. Nevertheless, the maximum yield has been increased up to 5.5 times with the conic insert anode. In order to increase the neutron yield, we have introduced a krypton admixture to the deuterium filling gas and found that, for a krypton pressure of about 0.1 torr, the neutron yield increases by a factor of 3.5 for the flat insert and 1.5 for the conic insert anodes. (author)

  16. Translate rotate scanning method for X-ray imaging

    International Nuclear Information System (INIS)

    Eberhard, J.W.; Kwog Cheong Tam.

    1990-01-01

    Rapid x-ray inspection of objects larger than an x-ray detector array is based on a translate rotate scanning motion of the object related to the fan beam source and detector. The scan for computerized tomography imaging is accomplished by rotating the object through 360 degrees at two or more positions relative to the source and detector array, in moving to another position the object is rotated and the object or source and detector are translated. A partial set of x-ray data is acquired at every position which are combined to obtain a full data set for complete image reconstruction. X-ray data for digital radiography imaging is acquired by scanning the object vertically at a first position at one view angle, rotating and translating the object relative to the source and detector to a second position, scanning vertically, and so on to cover the object field of view, and combining the partial data sets. (author)

  17. Preliminary neutron and X-ray crystallographic studies of equine cyanomethemoglobin

    International Nuclear Information System (INIS)

    Kovalevsky, A. Y.; Fisher, S. Zoe; Seaver, Sean; Mustyakimov, Marat; Sukumar, Narayanasami; Langan, Paul; Mueser, Timothy C.; Hanson, B. Leif

    2010-01-01

    Equine cyanomethemoglobin has been crystallized and X-ray and neutron diffraction data have been measured. Joint X-ray–neutron refinement is under way; the structural results should help to elucidate the differences between the hemoglobin R and T states. Room-temperature and 100 K X-ray and room-temperature neutron diffraction data have been measured from equine cyanomethemoglobin to 1.7 Å resolution using a home source, to 1.6 Å resolution on NE-CAT at the Advanced Photon Source and to 2.0 Å resolution on the PCS at Los Alamos Neutron Science Center, respectively. The cyanomethemoglobin is in the R state and preliminary room-temperature electron and neutron scattering density maps clearly show the protonation states of potential Bohr groups. Interestingly, a water molecule that is in the vicinity of the heme group and coordinated to the distal histidine appears to be expelled from this site in the low-temperature structure

  18. Moving-Article X-Ray Imaging System and Method for 3-D Image Generation

    Science.gov (United States)

    Fernandez, Kenneth R. (Inventor)

    2012-01-01

    An x-ray imaging system and method for a moving article are provided for an article moved along a linear direction of travel while the article is exposed to non-overlapping x-ray beams. A plurality of parallel linear sensor arrays are disposed in the x-ray beams after they pass through the article. More specifically, a first half of the plurality are disposed in a first of the x-ray beams while a second half of the plurality are disposed in a second of the x-ray beams. Each of the parallel linear sensor arrays is oriented perpendicular to the linear direction of travel. Each of the parallel linear sensor arrays in the first half is matched to a corresponding one of the parallel linear sensor arrays in the second half in terms of an angular position in the first of the x-ray beams and the second of the x-ray beams, respectively.

  19. Characterization of Nanocellulose Using Small-Angle Neutron, X-ray, and Dynamic Light Scattering Techniques.

    Science.gov (United States)

    Mao, Yimin; Liu, Kai; Zhan, Chengbo; Geng, Lihong; Chu, Benjamin; Hsiao, Benjamin S

    2017-02-16

    Nanocellulose extracted from wood pulps using TEMPO (2,2,6,6-tetramethylpiperidine-1-oxyl radical)-mediated oxidation and sulfuric acid hydrolysis methods was characterized by small-angle neutron scattering (SANS), small-angle X-ray scattering (SAXS), and dynamic light scattering (DLS) techniques. The dimensions of this nanocellulose (TEMPO-oxidized cellulose nanofiber (TOCN) and sulfuric acid hydrolyzed cellulose nanocrystal (SACN)) revealed by the different scattering methods were compared with those characterized by transmission electron microscopy (TEM). The SANS and SAXS data were analyzed using a parallelepiped-based form factor. The width and thickness of the nanocellulose cross section were ∼8 and ∼2 nm for TOCN and ∼20 and ∼3 nm for SACN, respectively, where the fitting results from SANS and SAXS profiles were consistent with each other. DLS was carried out under both the V V mode with the polarizer and analyzer parallel to each other and the H V mode having them perpendicular to each other. Using rotational and translational diffusion coefficients obtained under the H V mode yielded a nanocellulose length qualitatively consistent with that observed by TEM, whereas the length derived by the translational diffusion coefficient under the V V mode appeared to be overestimated.

  20. Effects of x-ray and neutron irradiation on spherical colonies

    International Nuclear Information System (INIS)

    Aramaki, Ryoji

    1980-01-01

    Responses of in vitro cultured mammalian cells in spherical colonies to 200 kVp x-rays and D-T neutrons were studied using reproductive capacity as a criterion for survival. Cell lines used were FM3A, L5 and Chinese hamster V79. The spherical colonies exposed to x-rays exhibited two-component survival curves. All cells used were more radio-resistant in spherical colonies than in single cell suspensions. It was suggested that this difference in response was attributable to the presence of hypoxic cells in spherical colonies. Dose-modifying Factor (DMF), the ratios of D 0 of the second slopes of the curves for spherical colonies to those for single cells, were 1.6 for FM3A, 1.8 for L5, and 1.7 for Chinese hamster V79. The hypoxic cell fractions in spherical colonies for FM3A, L5, and Chinese hamster V79, were 0.1, 0.6 and 0.4, respectively, resulting in variations in cell survival in spherical colonies following x-radiation. No significant difference was observed between responses of spherical colonies and single cell suspensions to D-T neutrons. FM3A and Chinese hamster V79 showed two-component survival curves when irradiated with neutrons at 37 0 C, but not at 25 0 C. The repair of potentially lethal and sub-lethal damage was also investigated using FM3A in spherical colonies. No detectable repair of potentially lethal damage was observed for x-rays and D-T neutrons. The effect of neutron fractionation was considerably smaller for spherical colonies as compared to single cells. (author)

  1. A concept to collect neutron and x-ray images on the same line of sight at NIF

    Energy Technology Data Exchange (ETDEWEB)

    Merrill, F. E., E-mail: fmerrill@lanl.gov; Danly, C. R.; Grim, G. P.; Volegov, P. L.; Wilde, C. H. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Izumi, N.; Jedlovec, D.; Fittinghoff, D. N.; Pak, A.; Park, H.-S. [Livermore National Laboratory, Livermore, California 94551 (United States)

    2014-11-15

    Neutron and x-ray images are collected at the National Ignition Facility (NIF) to measure the size and shape of inertial confinement fusion implosions. The x-ray images provide a measure of the size and shape of the hot region of the deuterium-tritium fuel while the neutron images provide a measure of the size and shape of the burning plasma. Although these two types of images are collected simultaneously, they are not collected along the same line of sight (LOS). One 14 MeV neutron image is collected on the NIF equator, and two x-ray images are collected along the polar axis and nearly perpendicular to the neutron imaging line of sight on the equator. Both measurements use pinhole apertures to form the images, but existing x-ray imaging provides time-resolved measurements while the neutron images are time-integrated. Detailed comparisons of the x-ray and neutron images can provide information on the fuel assembly, but these studies have been limited because the implosions are not azimuthally symmetric and the images are collected along different LOS. We have developed a conceptual design of a time-integrated x-ray imaging system that could be added to the existing neutron imaging LOS. This new system would allow these detailed studies, providing important information on the fuel assembly of future implosions. Here we present this conceptual design and the expected performance characteristics.

  2. A concept to collect neutron and x-ray images on the same line of sight at NIF.

    Science.gov (United States)

    Merrill, F E; Danly, C R; Izumi, N; Jedlovec, D; Fittinghoff, D N; Grim, G P; Pak, A; Park, H-S; Volegov, P L; Wilde, C H

    2014-11-01

    Neutron and x-ray images are collected at the National Ignition Facility (NIF) to measure the size and shape of inertial confinement fusion implosions. The x-ray images provide a measure of the size and shape of the hot region of the deuterium-tritium fuel while the neutron images provide a measure of the size and shape of the burning plasma. Although these two types of images are collected simultaneously, they are not collected along the same line of sight (LOS). One 14 MeV neutron image is collected on the NIF equator, and two x-ray images are collected along the polar axis and nearly perpendicular to the neutron imaging line of sight on the equator. Both measurements use pinhole apertures to form the images, but existing x-ray imaging provides time-resolved measurements while the neutron images are time-integrated. Detailed comparisons of the x-ray and neutron images can provide information on the fuel assembly, but these studies have been limited because the implosions are not azimuthally symmetric and the images are collected along different LOS. We have developed a conceptual design of a time-integrated x-ray imaging system that could be added to the existing neutron imaging LOS. This new system would allow these detailed studies, providing important information on the fuel assembly of future implosions. Here we present this conceptual design and the expected performance characteristics.

  3. Induction of micronuclei in the root tip cells of Haplopappus germinating seeds by fission neutrons and X rays

    International Nuclear Information System (INIS)

    Hanmoto, Hidehiro; Yonezawa, Yoshihiko; Itoh, Tetsuo; Kondo, Sohei.

    1992-01-01

    Seeds of Haplopappus gracilis (2n=4), an annual Compositae, were soaked in water for 24 hr and then irradiated with fission neutrons from the 1-wattage reactor, UTR-KINKI, or X rays. The root tip cells were inspected at 48 hr post-irradiation for evidence of chromosome damage using micronucleus as endpoint. The frequency of neutron-induced micronuclei increased almost linearly as the dose increased up to as much as 1.2 Gy. X-ray-induced micronuclei showed an exponential dose-response relation. From dose-response data, we estimated that the dose necessary to induce micronuclei at a frequency of 5 per 1,000 cells was 1.2 Gy for neutrons and 8.6 Gy for X rays. Thus, to induce chromosome damage in the somatic cells of germinating Haplopappus seeds, fission neutrons were much more effective than X rays. (author)

  4. Study of the elemental composition of Chenopodium Quinoa Willd by fast neutron activation analysis and X ray fluorescence analysis

    International Nuclear Information System (INIS)

    Soto Moran, R.L.; Szegedi, S.; Llopiz, J.L.

    1996-01-01

    By means of x-ray fluorescence and fast neutron activation analysis the nitrogen content has been determined in samples of roots, stems, leaf, flowers and grains from Quinua (Chenopodium Quinoa Willd), which was previously treated with fertilizer

  5. X-ray and neutron tomography on the bony inner ear of baleen whales

    International Nuclear Information System (INIS)

    Arlt, Tobias; Wieder, Frank; Hampe, Oliver; Manke, Ingo; Ritsche, Indira; Fahlke, Julia M.

    2018-01-01

    During their evolution whales and dolphins developed a highly specialized hearing organ for orientation in their deep sea territory covering a broad acoustic spectrum. The internal anatomy of the periotic bone, especially the morphology of the cochlea, has a significant influence on the hearing capability of mammals. The bony and fossilized cochleae of several fossil representatives of extinct baleen whales (e.g., Cetotheriidae) and modern rorquals (Balaenopteridae) and right whales, as well as cochleae of an archaeocete and some land mammals are investigated by X-ray and neutron tomography in order to record morphological changes that may be responsible for the development of low frequency hearing. Differences in the cochlear morphology have been determined by means of morphometric parameters, such as the number of turns, the length of the cochlea, and the curvature of the cochlear canal. In particular, X-ray tomography enables a high resolution display of the bony inner ear.

  6. Multielement characterization of atmospheric pollutants by x-ray fluorescence analysis and instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Rancitelli, L.A.; Tanner, T.M.

    1976-01-01

    The simultaneous measurement of a wide spectrum of elements in aerosols collected on air filters and in rainwater can yield information on the origin, transport, and removal of atmospheric pollutants. In order to determine the elemental content of these aerosols, a pair of highly sensitive, precise and complementing instrumental techniques, x-ray fluorescence and neutron activation analysis, have been developed and employed. Data are presented on the results of combined x-ray fluorescence and activation analysis of aerosols collected in a number of urban areas of the USA and from the 80th median sampling network in March 1972. From a comparison of these ratios in granite and diabase with those of filters placed in urban areas, it is evident that Zn, Se, Sb, Hg, and Pb levels have been increased by as much as several orders of magnitude. Al, Co, La, Fe, Eu, Sm, Tb, Ta, Hf, and Th appear to exist at levels compatible with an earth's crust origin

  7. Tokamak physics studies using x-ray diagnostic methods

    International Nuclear Information System (INIS)

    Hill, K.W.; Bitter, M.; von Goeler, S.

    1987-03-01

    X-ray diagnostic measurements have been used in a number of experiments to improve our understanding of important tokamak physics issues. The impurity content in TFTR plasmas, its sources and control have been clarified through soft x-ray pulse-height analysis (PHA) measurements. The dependence of intrinsic impurity concentrations and Z/sub eff/ on electron density, plasma current, limiter material and conditioning, and neutral-beam power have shown that the limiter is an important source of metal impurities. Neoclassical-like impurity peaking following hydrogen pellet injection into Alcator C and a strong effect of impurities on sawtooth behavior were demonstrated by x-ray imaging (XIS) measurements. Rapid inward motion of impurities and continuation of m = 1 activity following an internal disruption were demonstrated with XIS measurements on PLT using injected aluminum to enhance the signals. Ion temperatures up to 12 keV and a toroidal plasma rotation velocity up to 6 x 10 5 m/s have been measured by an x-ray crystal spectrometer (XCS) with up to 13 MW of 85-keV neutral-beam injection in TFTR. Precise wavelengths and relative intensities of x-ray lines in several helium-like ions and neon-like ions of silver have been measured in TFTR and PLT by the XCS. The data help to identify the important excitation processes predicted in atomic physics. Wavelengths of n = 3 to 2 silver lines of interest for x-ray lasers were measured, and precise instrument calibration techniques were developed. Electron thermal conductivity and sawtooth dynamics have been studied through XIS measurements on TFTR of heat-pulse propagation and compound sawteeth. A non-Maxwellian electron distribution function has been measured, and evidence of the Parail-Pogutse instability identified by hard x-ray PHA measurements on PLT during lower-hybrid current-drive experiments

  8. Investigation of microporosity in die-cast AlSi12(Cu) alloys by neutron- and X-ray radiography

    International Nuclear Information System (INIS)

    Zsolt, S.; Marton, B.

    1999-01-01

    The porosity of the casting can dramatically reduce the solidity and reliability of the objects made from aluminum alloys. The X-ray radiography is able to find the placement of the porosity of the aluminum devices. After a special 'water saturation' process the dynamic neutron radiography is available to discover the 'dangerous' surface nearporosity in the aluminum samples. The X-ray and neutron radiography were used as complementary examination techniques to study the porosity of the aluminum castings.(author)

  9. Compatibility study of the different pole figures in one and the same specimen. Comparison between the results obtained by neutron and by X-ray diffraction

    International Nuclear Information System (INIS)

    Pernot, M.; Penelle, R.; Dervin, P.

    1981-01-01

    Development of a calculation to show directly the compatibility of the different pole figures in the same specimen is exposed. A review of the method by serial development is given. Experimental methods are described. The position of the anisotropy axes is determined. Compatibilities resulting from X-ray and from neutron diffraction is analysed [fr

  10. Neutronics analysis for the ITER core imaging X-ray spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Serikov, Arkady, E-mail: arkady.serikov@kit.edu [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Fischer, Ulrich [Karlsruhe Institute of Technology (KIT), Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Suarez, Alejandro; Barnsley, Robin; Bertalot, Luciano; O’Connor, Richard; Thenevin, Raphaël; Udintsev, Victor S. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2016-11-01

    Highlights: • Proposed substantial radiation shielding design improvements of the CIXS system. • Radiation protection of the CIXS Port Interspace (PI) to provide personnel access. • The SDDR at PI was reduced by 100× from 2 mSv/h to 20 microSv/h. • A screen plate as a temporary shield at the CIXS maintenance period has been proposed. • The shadow effect created by a screen plate reduces SDDR by 9×. - Abstract: This paper presents new results of the MCNP neutronics analysis for the core imaging X-ray spectrometer (CIXS) system of the ITER Equatorial Port Plug #17 (EPP#17). Substantial radiation shielding design improvements of the CIXS system have been suggested as the outcomes of this analysis. These suggested improvements allow reaching two major goals: (1) radiation protection of the CIXS Port Interspace (PI) to provide personnel access for maintenance of the vacuum extension flange; (2) reduction of the neutron and gamma loads on the detectors to reduce the need for maintenance itself. By implementing the improvements in our models such as filling void spaces around the CIXS beams with boron carbide and inserting the tungsten collimators in the narrowed beam channel, we were able to reduce the Shut-Down Dose Rate (SDDR) in the PI by 100× from 2 mSv/h in the original CIXS design to 20 microSv/h. In case of non-changed MCNP geometry, the D1S method was applied in calculations of SDDR. To allow the maintenance access to the flange, a part of shielding was removed, therefore the R2Smesh methodology was applied instead of D1S. During the maintenance access of CIXS from the PI side, a screen plate was proposed to introduce behind which a worker receives much less SDDR.

  11. Application of instrumental neutron activation and X-ray fluorescence analysis to the examination of objects of art

    Science.gov (United States)

    Panczyk, E.; Ligeza, M.; Walis, L.

    1999-01-01

    In the Institute of Nuclear Chemistry and Technology in Warsaw in collaboration with the Department of Preservation and Restoration of Works of Art of the Academy of Fine Arts in Cracow and National Museum in Warsaw systematic studies using nuclear methods, particulary instrumental neutron activation analysis and X-ray fluorescence analysis, have been carried out on the panel paintings from the Krakowska- Nowosadecka School and Silesian School of the period from the XIV-XVII century, Chinese and Thai porcelains and mummies fillings of Egyptian sarcophagi. These studies will provide new data to the existing data base, will permit to compare materials used by various schools and individual artists.

  12. Radioisotope x-ray fluorescence and neutron activation analyses of the trace element concentrations of the rainbow trout

    International Nuclear Information System (INIS)

    Akyuz, T.; Bassari, A.; Bolcal, C.; Sener, E.; Yildiz, M.; Kucer, R.; Kaplan, Z.; Dogan, G.; Akyuz, S.

    1999-01-01

    The muscles and livers of the ten rainbow trouts (Oncorhynchus mykiss; N, 1752) obtained from Sapanca, Aquaculture Facility of Aquatic Products Faculty, The University of Istanbul (Turkey), have been analysed quantitatively for some minor elements using the radioisotope energy dispersive X-ray fluorescence (EDXRF) and neutron activation analysis (NAA) methods. It was found that samples contain Na, K, Ca, Sc, Cs, Fe, Co, Cu, Zn, Se, Br, Rb, Sr, Au, La and Ce in different amounts. Comparison of the results with those of reference river fish samples indicated that agricultural rainbow trout samples from Sapanca region have higher Fe level. (author)

  13. Application of instrumental neutron activation and X-ray fluorescence analysis to the examination of objects of art

    International Nuclear Information System (INIS)

    Panczyk, E.; Ligeza, M.; Walis, L.

    1999-01-01

    In the Institute of Nuclear Chemistry and Technology in Warsaw in collaboration with the Department of Preservation and Restoration of Works of Art of the Academy of Fine Arts in Cracow and National Museum in Warsaw systematic studies using nuclear methods, particularly instrumental neutron activation analysis and X-ray fluorescence analysis, have been carried out on the panel paintings from the Krakowska-Nowosadecka School and Silesian School of the period from the XIV-XVII century, Chinese and Thai porcelains and mummies fillings of Egyptian sarcophagi. These studies will provide new data to the existing data base, will permit to compare materials used by various schools and individual artists. (author)

  14. Radioisotope X-ray fluorescence and neutron activation analyses of the trace element concentrations of the rainbow trout

    Science.gov (United States)

    Akyuz, T.; Bassari, A.; Bolcal, C.; Sener, E.; Yildiz, M.; Kucer, R.; Kaplan, Z.; Dogan, G.; Akyuz, S.

    1999-01-01

    The muscles and livers of the ten rainbow trouts ( Oncorhynchus mykiss; N, 1752) obtained from Sapanca, Aquaculture Facility of Aquatic Products Faculty, The University of Istanbul (Turkey), have been analysed quantitatively for some minor elements using the radioisotope energy dispersive X-ray fluorescence (EDXRF) and neutron activation analysis (NAA) methods. It was found that samples contain Na, K, Ca, Sc, Cs, Fe, Co, Cu, Zn, Se, Br, Rb, Sr, Au, La and Ce in different amounts. Comparison of the results with those of reference river fish samples indicated that agricultural rainbow trout samples from Sapanca region have higher Fe level.

  15. X-ray and neutron scattering on disordered nanosize clusters: a case study of lead-zirconate-titanate solid solutions

    Energy Technology Data Exchange (ETDEWEB)

    Frantti, Johannes; Fujioka, Yukari [Finnish Research and Engineering, Helsinki (Finland)

    2015-04-01

    Defects and frequently used defect models of solids are reviewed. Signatures for identifying the disorder from x-ray and neutron scattering data are given. To give illustrative examples how technologically important defects contribute to x-ray and neutron scattering numerical method able to treat non-periodical solids possessing several simultaneous defect types is given for simulating scattering in nanosize disordered clusters. The approach takes particle size, shape, and defects into account and isolates element specific signals. As a case study a statistical approximation model for lead-zirconate titanate [Pb(Zr{sub x}Ti{sub 1-x})O{sub 3}, PZT] is introduced. PZT is a material possessing several defect types, including substitutional, displacement and surface defects. Spatial composition variation is taken into account by introducing a model in which the edge lengths of each cell depend on the distribution of Zr and Ti ions in the cluster. Spatially varying edge lengths and angles is referred to as microstrain. The model is applied to compute the scattering from ellipsoid shaped PZT clusters and to simulate the structural changes as a function of average composition. Two-phase co-existence range, the so called morphotropic phase boundary composition is given correctly. The composition at which the rhombohedral and tetragonal cells are equally abundant was x ∼ 0.51. Selected x-ray and neutron Bragg reflection intensities and line shapes were simulated. Examples of the effect of size and shape of the scattering clusters on diffraction patterns are given and the particle dimensions, computed through Scherrer equation, are compared with the exact cluster dimensions. Scattering from two types of 180 domains in spherical particles, one type assigned to Ti-rich PZT and the second to the MPB and Zr-rich PZT, is computed. We show how the method can be used for modelling polarization reversal. (copyright 2015 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. Spectral and Timing Nature of the Symbiotic X-Ray Binary 4U 1954+319: The Slowest Rotating Neutron Star in AN X-Ray Binary System

    Science.gov (United States)

    Enoto, Teruaki; Sasano, Makoto; Yamada, Shin'Ya; Tamagawa, Toru; Makishima, Kazuo; Pottschmidt, Katja; Marcu, Diana; Corbet, Robin H. D.; Fuerst, Felix; Wilms, Jorn

    2014-01-01

    The symbiotic X-ray binary (SyXB) 4U 1954+319 is a rare system hosting a peculiar neutron star (NS) and an M-type optical companion. Its approx. 5.4 hr NS spin period is the longest among all known accretion-powered pulsars and exhibited large (is approx. 7%) fluctuations over 8 yr. A spin trend transition was detected with Swift/BAT around an X-ray brightening in 2012. The source was in quiescent and bright states before and after this outburst based on 60 ks Suzaku observations in 2011 and 2012. The observed continuum is well described by a Comptonized model with the addition of a narrow 6.4 keV Fe-K alpha line during the outburst. Spectral similarities to slowly rotating pulsars in high-mass X-ray binaries, its high pulsed fraction (approx. 60%-80%), and the location in the Corbet diagram favor high B-field (approx. greater than 10(exp12) G) over a weak field as in low-mass X-ray binaries. The observed low X-ray luminosity (10(exp33)-10(exp35) erg s(exp-1)), probable wide orbit, and a slow stellar wind of this SyXB make quasi-spherical accretion in the subsonic settling regime a plausible model. Assuming a approx. 10(exp13) G NS, this scheme can explain the approx. 5.4 hr equilibrium rotation without employing the magnetar-like field (approx. 10(exp16) G) required in the disk accretion case. The timescales of multiple irregular flares (approx. 50 s) can also be attributed to the free-fall time from the Alfv´en shell for a approx. 10(exp13) G field. A physical interpretation of SyXBs beyond the canonical binary classifications is discussed.

  17. Modeling of neutron induced backgrounds in x-ray framing cameras

    Energy Technology Data Exchange (ETDEWEB)

    Hagmann, C.; Izumi, N.; Bell, P.; Bradley, D.; Conder, A.; Eckart, M.; Khater, H.; Koch, J.; Moody, J.; Stone, G. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2010-10-15

    Fast neutrons from inertial confinement fusion implosions pose a severe background to conventional multichannel plate (MCP)-based x-ray framing cameras for deuterium-tritium yields >10{sup 13}. Nuclear reactions of neutrons in photosensitive elements (charge coupled device or film) cause some of the image noise. In addition, inelastic neutron collisions in the detector and nearby components create a large gamma pulse. The background from the resulting secondary charged particles is twofold: (1) production of light through the Cherenkov effect in optical components and by excitation of the MCP phosphor and (2) direct excitation of the photosensitive elements. We give theoretical estimates of the various contributions to the overall noise and present mitigation strategies for operating in high yield environments.

  18. The effect of mixed fractionation with X rays and neutrons on tumour growth delay and skin reactions in mice

    International Nuclear Information System (INIS)

    Carl, U.M.

    1987-01-01

    The authors have compared the effects of mixed fractionation schedules with X rays and neutrons on growth delay of a murine tumour and skin reactions in mice. The schedules were five daily fractions of X rays, neutrons or mixtures (NNXXX, XXXNN or NXXXN). For clamped tumours or skin all three mixed schedules had the same effect. In contrast, for unclamped tumours giving the neutrons first (NNXXX) was more effective than the other two mixed schedules. This represented a true therapeutic gain and implies that if neutrons are used clinically as only part of a course of fractionated radiotherapy, they should be given at the beginning rather than at the end of treatment. (author)

  19. Neutron and hard x-ray measurements during pellet deposition in TFTR

    Energy Technology Data Exchange (ETDEWEB)

    Heidbrink, W.W.; Milora, S.L.; Schmidt, G.L.; Schneider, W.; Ramsey, A.

    1986-06-01

    Measurements of neutrons and hard x rays are made with a pair of plastic scintillators during injection of deuterium pellets into deuterium TFTR plasmas. Three cases are investigated. During ohmic heating in plasmas with few runaway electrons, the neutron emission does not increase when a pellet is injected, indicating that strong acceleration of the pellet ions does not occur. In ohmic plasmas with low but detectable levels of runaway electrons, an x-ray burst is observed on a detector near the pellet injector as the pellet ablates, while a detector displaced 126/sup 0/ toroidally from the injector does not measure a synchronous burst. Reduced pellet penetration correlates with the presence of x-ray emission, suggesting that the origin of the burst is bremsstrahlung from runaway electrons that strike the solid pellet. In deuterium beam-heated discharges, an increase in the d-d neutron emission is observed when the pellet ablates. In this case, the increase is due to fusion reactions between beam ions and the high density neutral and plasma cloud produced by ablation of the pellet; this localized density perturbation equilibrates in about 700 ..mu..sec. Analysis of the data indicates that the density propagates without forming a sharp shock front with a rapid initial propagation velocity (greater than or equal to 2 x 10/sup 7/ cm/sec) that subsequently decreases to around 3 x 10/sup 6/ cm/sec. Modelling suggests that the electron heat flux into the pellet cloud is much less than the classical Spitzer value.

  20. Small angle neutron and x-ray scattering studies of self-assembled nano structured materials

    International Nuclear Information System (INIS)

    Choi, Sung Min

    2009-01-01

    Full text: Small angle neutron and x-ray scattering are very powerful techniques to investigate nano structured materials. In this presentation, examples of nano structured materials investigated by neutron and x-ray scattering will be presented. Part I: The unique anisotropic physical properties of columnar discotic liquid crystals (DLCs) have attracted considerable interest for their potential applications as electronic devices. For many practical applications, however, it is crucial to obtain uniaxially oriented and highly ordered columnar superstructures of DLC molecules covering macroscopic area. Here, we present a simple and straight-forward approach to fabricate uniaxially oriented and highly ordered columnar superstructures of cobalt octa(n-decylthio) porphyrazine (CoS 1 0), a discotic supra-molecule, in bulk and on substrates [1] over a macroscopic length scale, utilizing an applied magnetic field and the interaction of CoS 1 0 with an OTS-functionalized substrate. The details of the oriented and ordered columnar nano-structures are investigated by SANS and GISAXS. Part II: Self-assembly of one-dimensional (1D) nanoparticles with metallic or semiconducting properties into highly ordered superstructures using various interactions has been of great interest as a route towards materials with new functionalities. Here, we report a new phase diagram of negatively charged 1D nanoparticle (cROD) and cationic liposome (CL) complexes in water which exhibit three different highly ordered phases [2]. Small angle neutron and x-ray scattering measurements show that the cROD-CL complexes exhibit three different highly ordered phases, intercalated lamellar, doubly intercalated lamellar and centered rectangular phases, depending on particle curvature and electrostatic interactions. The new phase diagram can be used to understand and design new highly ordered self-assemblies of 1D nanoparticles in soft matter which provide new functionalities. (author)

  1. Application of the alanine detector to gamma-ray, X-ray and fast neutron dosimetry

    International Nuclear Information System (INIS)

    Waligorski, M.P.R.; Hansen, J.W.; Byrski, E.

    1987-01-01

    A dosimeter based on alanine has been developed at the INP in Krakow and at Risoe National Laboratory. Due to its near tissue-equivalence and stability of signal, measured using ESR spectrometry at room temperature, this free-radical amino-acid dosimetric system is particularly suitable for measuring X-ray, gamma-ray and fast neutron doses in the range 10-10 5 Gy. The relative effectiveness (with respect to 60 Co γ-rays) of the alanine dosimeter to 250 kVp X-rays and to cyclotron-produced fast neutrons (mean neutron energy 5.6 MeV) is measured to be 0.76± 0.06 and 0.60±0.05, respectively. The suitability of the alanine dosimeter for intercomparison gamma-ray dosimetry is also shown. The estimated absolute difference between 60 Co dosimetry at Risoe National Laboratory and at the Centre of Oncology in Krakow is about 5%, somewhat more than the experimental uncertainty. These results are based on ESR measurements performed in Krakow on about 25% of the exposed detectors. 28 refs., 2 figs., 3 tabs. (author)

  2. Magnetic field strength of a neutron-star-powered ultraluminous X-ray source

    Science.gov (United States)

    Brightman, M.; Harrison, F. A.; Fürst, F.; Middleton, M. J.; Walton, D. J.; Stern, D.; Fabian, A. C.; Heida, M.; Barret, D.; Bachetti, M.

    2018-04-01

    Ultraluminous X-ray sources (ULXs) are bright X-ray sources in nearby galaxies not associated with the central supermassive black hole. Their luminosities imply they are powered by either an extreme accretion rate onto a compact stellar remnant, or an intermediate mass ( 100-105M⊙) black hole1. Recently detected coherent pulsations coming from three bright ULXs2-5 demonstrate that some of these sources are powered by accretion onto a neutron star, implying accretion rates significantly in excess of the Eddington limit, a high degree of geometric beaming, or both. The physical challenges associated with the high implied accretion rates can be mitigated if the neutron star surface field is very high (1014 G)6, since this suppresses the electron scattering cross-section, reducing the radiation pressure that chokes off accretion for high luminosities. Surface magnetic field strengths can be determined through cyclotron resonance scattering features7,8 produced by the transition of charged particles between quantized Landau levels. Here, we present the detection at a significance of 3.8σ of an absorption line at 4.5 keV in the Chandra spectrum of a ULX in M51. This feature is likely to be a cyclotron resonance scattering feature produced by the strong magnetic field of a neutron star. Assuming scattering off electrons, the magnetic field strength is implied to be 1011 G, while protons would imply a magnetic field of B 1015 G.

  3. Characterization of cryogenic materials by x-ray absorption methods

    International Nuclear Information System (INIS)

    Heald, S.M.; Tranquada, J.M.

    1985-01-01

    X-ray absorption techniques have in recent years been developed into powerful probes of the electronic and structural properties of materials difficult to study by other techniques. In particular, the extended x-ray absorption fine structure (EXAFS) technique can be applied to a variety of cryogenic materials. Three examples are used to demonstrate the power of the technique. The first is the determination of the lattice location of dilute alloying additions such as Ta and Zr in Nb 3 Sn. The Ta additions are shown to reside predominately in Nb lattice sites, while Zr is not uniquely located at either Nb or Sn sites. In addition to structural information, temperature dependent EXAFS studies can be used to determine the rms deviations of atomic bond lengths, providing information about the temperature dependence of interatomic force constants. For Nb 3 Sn deviations are found from simple harmonic behavior at low temperatures which indicate a softening of the Nb-Sn bond strength. The final example is the study of interfacial properties in thin film systems. This is accomplished by making x-ray absorption measurements under conditions of total external reflection of the incident x-rays. As some examples show, this technique has great potential for studying interfacial reactions, a process used in the fabrication of many superconducting materials

  4. Metal micro-arrays for collimating neutrons and X-rays

    International Nuclear Information System (INIS)

    Allman, B.E.; Cimmino, A.; Klein, A.G.; Hamilton, W.A.

    1998-08-01

    The authors describe the theory, fabrication and experimental results of novel, compact optical elements for collimating and/or focusing beams of X-rays or thermal neutrons. These optical elements are solid composites consisting of regular stacks of alternating micro-foils, analogous in action to Soller slits. They are made out of pairs of metals with suitable refractive indices for reflection and/or absorption of the radiation. The performance of these proof-in-principle collimating elements is limited only by the choice of micro-foil materials and the uniformity of their interfaces

  5. Real Structure and Resudal Stresses in Advanced Welds Determined by X-ray and Neutron Diffraction

    Czech Academy of Sciences Publication Activity Database

    Trojan, K.; Hervoches, Charles; Ganev, N.; Mikula, Pavol; Čapek, J.

    2017-01-01

    Roč. 9, SEP (2017), s. 32-38 E-ISSN 2336-5382 R&D Projects: GA MŠk LM2015056; GA ČR GB14-36566G Institutional support: RVO:61389005 Keywords : laser and MAG welding * residual stresses * X-ray diffraction * neutron diffraction Subject RIV: BM - Solid Matter Physics ; Magnetism OBOR OECD: Condensed matter physics (including formerly solid state physics, supercond.) https://ojs.cvut.cz/ojs/index.php/APP/article/view/4401/4298

  6. Observation of Ortho-III correlations by neutron and hard x-ray scattering in an untwinned YBa2Cu3O6.77 single crystal

    DEFF Research Database (Denmark)

    Schleger, P.; Casalta, H.; Hadfield, R.

    1995-01-01

    We present measurements of Ortho-III phase correlations in an untwinned single crystal of YBa2Cu3O6.77 by neutron scattering and the novel method of hard (95 keV) X-ray scattering. The Ortho-III ordering is essentially two-dimensional, exhibiting Lorentzian peak shapes in the a-b plane. At room...

  7. On the methods of determination of x-ray sources protection quality in x-ray diagnostic equipment

    International Nuclear Information System (INIS)

    Vladimirov, L.V.

    1973-01-01

    Existing procedures for assessing the quality of shielding of X-ray radiators are compared; these procedures are shown to have a number of shortcomings and to be very time-consuming. A procedure is offered in which shielding quality is tested in two stages: (1) X-ray tests aimed at determining the quality of protection of the X-ray tube unit; and (2) dosimeter tests proper. The results of measurements are compared with maximum permissible dosage rate

  8. X-ray computed tomography imaging method which is immune to beam hardening effect

    International Nuclear Information System (INIS)

    Kanno, Ikuo; Uesaka, Akio; Nomiya, Seiichiro; Onabe, Hideaki

    2009-01-01

    For the easy treatment of cancers, early finding of them is an important theme of study. X-ray transmission measurement and computed tomography (CT) are powerful tools for finding cancers. The x-ray CT shows cross sectional view of human body and is able to detect small cancers such as 1 cm in diameter. The CT, however, gives very high dose exposure to human body: some 10 to 1000 times higher dose exposure than the chest radiography. It is not possible to have medical health check using CT frequently, in view of both individual and public accumulated dose exposures. The authors have been working on the reduction of dose exposure in x-ray transmission measurements in case of detecting iodine contrast media, which concentrates in cancers. In our method, energy information of x-rays is employed: in conventional x-ray transmission measurements, x-rays are measured as current and the energy of each x-ray is ignored. The numbers of x-ray events, φ 1 and φ 2 , of which energies are lower and higher than the one of iodine K-edge, respectively, are used for the estimation of iodine thickness in cancers. Moreover, high energy x-rays, which are not sensitive to the absorption by iodine, are cut by a filter made of higher atomic number material than iodine. We call this method filtered x-ray energy subtraction (FIX-ES) method. This FIX-ES method was shown twice as sensitive to iodine than current measurement method. With the choice of filter thickness, minimum dose exposure in FIX-ES is 30% of that when white x-rays are employed. In the study described above, we concentrated on the observation of cancer part. In this study, a cancer phantom in normal tissue is observed by FIX-ES method. The results are compared with the ones obtained by current measurement method. (author)

  9. A universal treatment of X-ray and neutron diffraction in crystals. II. Extinction

    International Nuclear Information System (INIS)

    Hu Huachen

    1997-01-01

    For pt.I see ibid., p.484-92, 1997. Based on the formalism for calculating the integrated reflection power ratio of a plane mosaic crystal by using three dimensionless parameters exact and universal expressions for the secondary-extinction factors in X-ray and neutron crystallography are developed that can be applied to reflections of all possible values of extinction factor, reflection symmetry and the absorption-to-scattering cross-section ratio of the crystal. The representation by three parameters gives a clear and definite physical meaning to the concept of extinction. The theory has been extended to treat the extinction of a spherical crystal, and the striking difference in the evaluated secondary-extinction factor between the equivalent single-plate and the exact method in the spherical-crystal treatment under θ B = 0 is explained. As a demonstration of the feasibility of using these expressions, the diffraction data for LiF and MgO crystal plates measured by Lawrence [Acta Cryst. (1972), A28, 400-404; (1973), A29, 208-210] are reanalyzed by this method. All the reflections including the strongest ones (Y o down to 0.026) are reanalyzed simultaneously with single-valued particle size and mosaic spread as fitting parameters and allowing for primary extinction if necessary. The results (R factor = 0.014 and 0.053 for LiF and MgO, respectively) are unprecedentedly good. Furthermore, in disagreement with Lawrence, the extinction of LiF is found to be of secondary type and in the case of MgO both primary and secondary extinction should be considered. The analysis also shows that the formula Y ∝ Y p Y s is valid only for very weak extinctions and that the Hamilton-Darwin equations are valid in a range much broader than previously anticipated. (orig.)

  10. Sulfur content measurement in coal by X-ray fluorescence method

    International Nuclear Information System (INIS)

    Cechak, T.; Thinova, L.

    2001-01-01

    X-ray fluorescence, using backscattering, was employed in the determination of sulfur content and ash content measurement in coal. The results of the methods are given to illustrate the differences between the chemical analysis and X-ray fluorescence method.

  11. Required doses for projection methods in X-ray diagnosis

    International Nuclear Information System (INIS)

    Hagemann, G.

    1992-01-01

    The ideal dose requirement has been stated by Cohen et al. (1981) by a formula basing on parallel beam, maximum quantum yield and Bucky grid effect depending on the signal to noise ratio and object contrast. This was checked by means of contrast detail diagrams measured at the hole phantom, and was additionally compared with measurement results obtained with acrylic glass phantoms. The optimal dose requirement is obtained by the maximum technically possible approach to the ideal requirement level. Examples are given, besides for x-ray equipment with Gd 2 O 2 S screen film systems for grid screen mammography, and new thoracic examination systems for mass screenings. Finally, a few values concerning the dose requirement or the analogous time required for fluorscent screening in angiography and interventional radiology, are stated, as well as for dentistry and paediatric x-ray diagnostics. (orig./HP) [de

  12. Method and apparatus involving the generation of x-rays

    International Nuclear Information System (INIS)

    Neal, W.R.; Little, R.G.

    1978-01-01

    An electron gun assembly generates an accelerated and sharply focused electron beam which is deflected in a predetermined path to impinge upon an extended split anode structure in a selected scanning pattern with approximately half the beam current impinging on each half of the split anode. A signal proportional to the difference between the two currents from each half of the split anode provides feedback control to the beam deflection system for constraining the beam to follow the fissure of the split anode. X-rays which are generated at the point of beam impingement on the split anode constitute a moving source of x-rays as the point of beam impingement travels in the selected pattern along the anode

  13. Super-Eddington accretion on to the neutron star NGC 7793 P13: Broad-band X-ray spectroscopy and ultraluminous X-ray sources

    Science.gov (United States)

    Walton, D. J.; Fürst, F.; Harrison, F. A.; Stern, D.; Bachetti, M.; Barret, D.; Brightman, M.; Fabian, A. C.; Middleton, M. J.; Ptak, A.; Tao, L.

    2018-02-01

    We present a detailed, broad-band X-ray spectral analysis of the ultraluminous X-ray source (ULX) pulsar NGC 7793 P13, a known super-Eddington source, utilizing data from the XMM-Newton, NuSTAR and Chandra observatories. The broad-band XMM-Newton+NuSTAR spectrum of P13 is qualitatively similar to the rest of the ULX sample with broad-band coverage, suggesting that additional ULXs in the known population may host neutron star accretors. Through time-averaged, phase-resolved and multi-epoch studies, we find that two non-pulsed thermal blackbody components with temperatures ∼0.5 and 1.5 keV are required to fit the data below 10 keV, in addition to a third continuum component which extends to higher energies and is associated with the pulsed emission from the accretion column. The characteristic radii of the thermal components appear to be comparable, and are too large to be associated with the neutron star itself, so the need for two components likely indicates the accretion flow outside the magnetosphere is complex. We suggest a scenario in which the thick inner disc expected for super-Eddington accretion begins to form, but is terminated by the neutron star's magnetic field soon after its onset, implying a limit of B ≲ 6 × 1012 G for the dipolar component of the central neutron star's magnetic field. Evidence of similar termination of the disc in other sources may offer a further means of identifying additional neutron star ULXs. Finally, we examine the spectrum exhibited by P13 during one of its unusual 'off' states. These data require both a hard power-law component, suggesting residual accretion on to the neutron star, and emission from a thermal plasma, which we argue is likely associated with the P13 system.

  14. Neutron und X-ray diffraction study on the superstructure of a sodium-rich low plagioclase An sub(16.5)

    International Nuclear Information System (INIS)

    Joswig, W.; Korekawa, M.

    1977-01-01

    Neutron and X-ray diffraction experiments had been carried out on a sodium-rich low plagioclase Ansub(16.5) from Sultan Hamud, Kenya. In constrast to previous work very weak (g) reflections (satellites) for all reflections Okl, except reflections 001, could be observed. It is shown that the neutron diffraction method is advantageous to study on submicroscopic periodic domain structure as reported here. (orig.) [de

  15. X-ray and neutron diffraction studies of the Peierls instability

    International Nuclear Information System (INIS)

    Renker, B.; Comes, R.

    1974-01-01

    The experimental techniques of X-ray and thermal neutron scattering provide a lot of information about the metal insulator transition in linear conductors. The enhanced Kohn anomaly which has been detected in KCP at room temperature proves 1d-metallic properties at higher temperatures. But additionally a very low frequency peak was found at the same wave vector which was explained by the assumption of critical fluctuations. Thus at room temperature one does not observe a real metallic state but the system already performs fluctuations around an equilibrum position which is the isolating state at lower temperatures. The fluctuations will cause the existence of a pseudo gap which is responsible for a reduced electron mobility and a hardening of the soft mode frequencies above 100 K. The temperature dependent intensity of the central component has been measured. The transition to the Peierls state where the fluctuations are frozen in, is caused by a 3d-ordering of the distortions impressed on the single chains. Finally it was found that this 3d-transition does not lead to a real long range ordered structure. It leads to domains which are fairly large in chain direction [xi > 170 A] but which are small perpendicular to that direction [xi = 33 A]. The X-ray experiments where performed at Orsay, and the neutron scattering experiments partly at the Karlsruhe FR2 reactor and the Grenoble ILL-high flux reactor. (orig./HK) [de

  16. Recent developments in X-ray and neutron small-angle scattering instrumentation and data analysis

    International Nuclear Information System (INIS)

    Schelten, J.

    1978-01-01

    The developments in instrumentation and data analysis that have occurred in the field of small-angle X-ray and neutron scattering since 1973 are reviewed. For X-rays, the cone camera collimation was invented, synchrotrons and storage rings were demonstrated to be intense sources of X-radiation, and one- and two-dimensional position-sensitive detectors were interfaced to cameras with both point and line collimation. For neutrons, the collimators and detectors on the Juelich and Grenoble machines were improved, new D11-type instruments were built or are under construction at several sites, double-crystal instruments were set up, and various new machines have been proposed. Significant progress in data analysis and evaluation has been made through application of mathematical techniques such as the use of spline functions, error minimization with constraints, and linear programming. Several special experiments, unusual in respect to the anisotropy of the scattering pattern, gravitational effects, moving scatterers, and dynamic fast time slicing, are discussed. (Auth.)

  17. Accretion dynamics and polarized x-ray emission of magnetized neutron stars

    International Nuclear Information System (INIS)

    Arons, J.

    1991-01-01

    The basic ideas of accretion onto magnetized neutron stars are outlined. These are applied to a simple model of the structure of the plasma mound sitting at the magnetic poles of such as star, in which upward diffusion of photons is balanced by their downward advection. This steady flow model of the plasma's dynamical state is used to compute the emission of polarized X-rays from the optically thick, birefringent medium. The linear polarization of the continuum radiation emerging from the quasi-static mound is found to be as much as 40% at some rotation phases, but is insensitive to the geometry of the accretion flow. The role of the accretion shock, whose detailed polarimetric and spectral characteristics have yet to be calculated, is emphasized as the final determinant of the properties of the emerging X-rays. Some results describing the fully time dependent dynamics of the flow are also presented. In particular, steady flow onto a neutron star is shown to exhibit formation of ''photon bubbles,'' regions of greatly reduced plasma density filled with radiation which form and rise on millisecond time scales. The possible role of these complex structures in the flow for the formation of the emergent spectrum is briefly outlined

  18. In vivo monitoring of toxic metals: assessment of neutron activation and x-ray fluorescence techniques

    International Nuclear Information System (INIS)

    Ellis, K.J.

    1986-01-01

    To date, cadmium, lead, aluminum, and mercury have been measured in vivo in humans. The possibilities of monitoring other toxic metals have also been demonstrated, but no human studies have been performed. Neutron activation analysis appears to be most suitable for Cd and Al measurements, while x-ray fluorescence is ideally suited for measurement of lead in superficial bone. Filtered neutron beams and polarized x-ray sources are being developed which will improve in vivo detection limits. Even so, several of the current facilities are already suitable for use in epidemiological studies of selected populations with suspected long-term low-level ''environmental'' exposures. Evaluation and diagnosis of patients presenting with general clinical symptoms attributable to possible toxic metal exposure may be assisted by in vivo examination. Continued in vivo monitoring of industrial workers, especially follow-up measurements, will provide the first direct assessment of changes in body burden and a direct measure of the biological life-times of these metals in humans. 50 refs., 4 figs., 2 tabs

  19. First steps of ion beam mixing: study by X-ray reflectometry and neutron diffraction

    International Nuclear Information System (INIS)

    Le Boite, M.G.

    1987-12-01

    There are several processes involved in ion beam mixing: ballistic processes, chemical driving forces and radiation enhanced diffusion. Experiments usually performed on bilayers irradiated with heavy elements and characterized by Rutherford backscattering (R.B.S.), have shown that the measured mixing rate is always higher than the calculated one, taking into account ballistic effects only. Besides classical R.B.S. experiments on NiAu and NiPt bilayers irradiated with Xe, we have used another technique of characterization: X-ray reflectometry and neutron diffraction, performed on multilayers irradiated with He. The systems are NiAu, NiPt, NiPd and NiAg, which behave similarly from the ballistic point of view, but have very different heats of mixing. In these experiments, the range of deposited energy density is very low, in contrast to heavy ions irradiation: this has allowed us to reach very low diffusion coefficient, never observed before. The dependence of the diffusion coefficient on the heat of mixing is in agreement with the one theoretically calculated. For the NiAg system, which has a positive heat of mixing, the measured diffusion coefficient is smaller than the ballistic one: a decrease of the ballistic mixing rate is seen for the first time. In this work, we have shown the interest of the reflectometry techniques (X-ray and neutrons); we have used a simple model to analyze the ion beam mixing, when elementary processes are involved

  20. X-ray and neutron diffraction study of alums. Pt. 2 and 3

    International Nuclear Information System (INIS)

    Abdeen, A.M.; Will, G.; Schaefer, W.; Kirfel, A.; Bargouth, M.O.; Recker, K.; Weiss, A.

    1981-01-01

    The crystal structure of the alums, (NH 3 CH 3 )Al(SO 4 ) 2 x 12 H 2 0 and (NH 4 )AL(SO 4 ) 2 x 12 H 2 0, has been determined and refined from X-ray and neutron diffraction data. The compounds crystallize cubic in space group Pa3 (Z = 4). The positional and thermal parameters of all atoms including hydrogens have been refined by full matrix least-sqares analysis resulting in Rsub(w) values from the X-ray and neutron data of 0.030 and 0.029 respectively for the methylammonium alum and of 0.024 and 0.014 respectively for the ammonium alum. The atoms of the cation groups (NH 3 CH 3 ) + and (NH 4 ) + are distributed on 8(c) and 24(d) positions in two orientations of equal probability on and around the [111] direction related to each other by an inversion centre. The disorder in the cation groups is explained by a quantized rotation. Disorder in the sulfate groups has been determined to 4.2% for the methylammonium alum and to about 17% for the ammonium alum. The disordered sulfate tetrahedra are distorted and in a reversed orientation along the threefold axis. The system of the hydrogen bonds is discussed. (orig.)

  1. Neutrons and X-rays, comparative studies with Drosophila melanogaster. Pt. 2

    International Nuclear Information System (INIS)

    Leigh, B.; Veerkamp-van Baarle, A.M.A.; Sobels, F.H.; Broese, J.J.

    1981-01-01

    Losses and duplications of Bsup(S)Y γ + -chromosome markers werde induced by irradiation of spermatozoa with either 0.5-MeV neutrons or 100-kV X-rays. These 2 types of radiation are known to induce significantly different ratios of double:single strand breaks in DNA. Exceptional progeny were grouped into 3 categories; no Y marker, one Y marker, and Y marker duplications + mosaics. The last combination consisted of exceptions derived from only chromatid-type rearrangements. All other classes of exceptions may be derived from either chromatid- or chromosome-type rearrangements. Doses of 15 Gy neutrons and 27 Gy X-rays induced identical frequencies of exceptional progeny, giving an RBE of 1.8. The ratios of the 3 classes of exceptions were similar for both types of radiation. This observation can be interpreted as indicating that, under the conditions used here, chromosome and chromatid rearrangements are not derived directly from double and single DNA strand breaks, respectively. (orig.)

  2. Method and device for X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Jagoutz, E.; Palme, C.

    1978-01-01

    In the x-ray fluorescence analyzer the useful signal can be completely separated from the spurious signals, and especially the pulse can be determined. For this purpose the output of the radiation detector is connected with a multichannel pulse height discriminator. The measured signal determined in the pulse heigth discriminator may be indicated by a visual display or processed by a computer (coincidence circuits). (DG) [de

  3. ASSESSMENT OF RESTORATION METHODS OF X-RAY IMAGES WITH EMPHASIS ON MEDICAL PHOTOGRAMMETRIC USAGE

    Directory of Open Access Journals (Sweden)

    S. Hosseinian

    2016-06-01

    Full Text Available Nowadays, various medical X-ray imaging methods such as digital radiography, computed tomography and fluoroscopy are used as important tools in diagnostic and operative processes especially in the computer and robotic assisted surgeries. The procedures of extracting information from these images require appropriate deblurring and denoising processes on the pre- and intra-operative images in order to obtain more accurate information. This issue becomes more considerable when the X-ray images are planned to be employed in the photogrammetric processes for 3D reconstruction from multi-view X-ray images since, accurate data should be extracted from images for 3D modelling and the quality of X-ray images affects directly on the results of the algorithms. For restoration of X-ray images, it is essential to consider the nature and characteristics of these kinds of images. X-ray images exhibit severe quantum noise due to limited X-ray photons involved. The assumptions of Gaussian modelling are not appropriate for photon-limited images such as X-ray images, because of the nature of signal-dependant quantum noise. These images are generally modelled by Poisson distribution which is the most common model for low-intensity imaging. In this paper, existing methods are evaluated. For this purpose, after demonstrating the properties of medical X-ray images, the more efficient and recommended methods for restoration of X-ray images would be described and assessed. After explaining these approaches, they are implemented on samples from different kinds of X-ray images. By considering the results, it is concluded that using PURE-LET, provides more effective and efficient denoising than other examined methods in this research.

  4. Neutron activation analysis technique and X-ray fluorescence in bovine liver sample

    International Nuclear Information System (INIS)

    Maihara, V.A.; Favaro, D.I.T.; Vasconcellos, M.B.A.; Sato, I.M.; Salvador, V.L.

    2002-01-01

    Many analytical techniques have been used in food and diet analysis in order to determine a great number of nutritional elements, ranging from percentage to ng g -1 , with high sensitivity and accuracy. Instrumental Neutron activation Analysis (INAA) has been employed to certificate many trace elements in biological reference materials. More recently, the X-Ray Fluorescence (FRX-WD) has been also used to determine some essential elements in food samples. The INAA has been applied in nutrition studies in our laboratory at IPEN since the 80 s. For the development of analytical methodologies the use of the reference materials with the same characteristics of the sample analyzed is essential. Several Brazilian laboratories do not have conditions to use these materials due their high cost.In this paper preliminary results of commercial bovine liver sample analyses obtained by INAA and WD-XRF methods are presented. This sample was prepared to be a Brazilian candidate of reference material for a group of laboratories participating in a research project sponsored by FAPESP. The concentrations of some elements like Cl, K, Na, P, S and trace elements Br, Ca, Co, Cu, Fe, Mg, Mn, Mo, Rb, Se and Zn were determined by INAA and WD-XFR. For validation methodology of both techniques, NIST SRM 1577b Bovine Liver reference material was analyzed and the detection limits were calculated. The concentrations of elements determined by both analytical techniques were compared by using the Student's t-test and for Cl, Cu, Fe, K, Mg, Na, Rn and Zn the results do show no statistical difference for 95% significance level. (author)

  5. Method of making tomographic images of X-rayed objects

    International Nuclear Information System (INIS)

    Eickel, R.

    1979-01-01

    A tomographic image of a selected layer of a stationary object is made by moving the source of X-rays along a first path at one side of the selected layer and by moving an ionography imaging chamber which contains a dielectric receptor sheet along a second path at the other side of the selected layer. The movement of the sheet is synchronized with movement of the source of X-rays and includes a translatory movement in a direction counter to the direction of movement of the source, a pivotal movement to maintain the sheet in a plane which is normal to the central beam of the bundle of X-rays, and a sidewise movement to vary the distance between the selected layer and the sheet so that the length of the projection of selected layer upon the sheet remains unchanged. If the sheet is rectangular, the pivotal movement is performed about an axis which is located in the plane of the selected layer and is parallel to the shorter sides of the sheet

  6. Three-dimensional reconstruction of neutron, gamma-ray, and x-ray sources using spherical harmonic decomposition

    Science.gov (United States)

    Volegov, P. L.; Danly, C. R.; Fittinghoff, D.; Geppert-Kleinrath, V.; Grim, G.; Merrill, F. E.; Wilde, C. H.

    2017-11-01

    Neutron, gamma-ray, and x-ray imaging are important diagnostic tools at the National Ignition Facility (NIF) for measuring the two-dimensional (2D) size and shape of the neutron producing region, for probing the remaining ablator and measuring the extent of the DT plasmas during the stagnation phase of Inertial Confinement Fusion implosions. Due to the difficulty and expense of building these imagers, at most only a few two-dimensional projections images will be available to reconstruct the three-dimensional (3D) sources. In this paper, we present a technique that has been developed for the 3D reconstruction of neutron, gamma-ray, and x-ray sources from a minimal number of 2D projections using spherical harmonics decomposition. We present the detailed algorithms used for this characterization and the results of reconstructed sources from experimental neutron and x-ray data collected at OMEGA and NIF.

  7. Preferred orientation of a naturally and experimentally deformed pyrrhotite ore by X-ray and neutron diffraction texture analysis

    International Nuclear Information System (INIS)

    Niederschlag, E.; Brokmeier, H.G.; Siemes, H.

    1994-01-01

    Two samples of polycrystalline naturally deformed hexagonal Pyrrhotite were deformed experimentally in axial compression tests with different temperatures and strain. The texture of the naturally deformed ore was investigated both by X-ray and neutron texture analyses. Texture measurements on the experimentally deformed ore were carried out by neutron diffraction. (orig.)

  8. X-ray studies on electrochemical systems. Synchrotron methods for energy materials

    Energy Technology Data Exchange (ETDEWEB)

    Braun, Artur [Empa. Eidgenoessische Materialpruefungs- und Forschungsanstalt, Duebendorf (Switzerland)

    2017-07-01

    This book is your graduate level entrance into battery, fuel cell and solar cell research at synchrotron X-ray sources. Materials scientists find numerous examples for the combination of electrochemical experiments with simple and with highly complex X-ray scattering and spectroscopy methods. Physicists and chemists can link applied electrochemistry with fundamental concepts of condensed matter physics, physical chemistry and surface science.

  9. Simultaneous neutron and x-ray imaging of inertial confinement fusion experiments along a single line of sight at Omega

    Energy Technology Data Exchange (ETDEWEB)

    Danly, C. R.; Day, T. H.; Herrmann, H.; Kim, Y. H.; Martinez, J. I.; Merrill, F. E.; Schmidt, D. W.; Simpson, R. A.; Volegov, P. L.; Wilde, C. H. [Los Alamos National Laboratory, Los Alamos, New Mexico 87544 (United States); Fittinghoff, D. N.; Izumi, N. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2015-04-15

    Neutron and x-ray imaging provide critical information about the geometry and hydrodynamics of inertial confinement fusion implosions. However, existing diagnostics at Omega and the National Ignition Facility (NIF) cannot produce images in both neutrons and x-rays along the same line of sight. This leads to difficulty comparing these images, which capture different parts of the plasma geometry, for the asymmetric implosions seen in present experiments. Further, even when opposing port neutron and x-ray images are available, they use different detectors and cannot provide positive information about the relative positions of the neutron and x-ray sources. A technique has been demonstrated on implosions at Omega that can capture x-ray images along the same line of sight as the neutron images. The technique is described, and data from a set of experiments are presented, along with a discussion of techniques for coregistration of the various images. It is concluded that the technique is viable and could provide valuable information if implemented on NIF in the near future.

  10. A CHANGE IN THE QUIESCENT X-RAY SPECTRUM OF THE NEUTRON STAR LOW-MASS X-RAY BINARY MXB 1659-29

    Energy Technology Data Exchange (ETDEWEB)

    Cackett, E. M. [Department of Physics and Astronomy, Wayne State University, 666 W. Hancock Street, Detroit, MI 48201 (United States); Brown, E. F. [Department of Physics and Astronomy, National Superconducting Cyclotron Laboratory, and the Joint Institute for Nuclear Astrophysics, Michigan State University, East Lansing, MI 48824 (United States); Cumming, A. [Department of Physics, McGill University, 3600 rue University, Montreal, QC H3A 2T8 (Canada); Degenaar, N.; Miller, J. M. [Department of Astronomy, University of Michigan, 500 Church Street, Ann Arbor, MI 48109-1042 (United States); Fridriksson, J. K.; Wijnands, R. [Astronomical Institute ' ' Anton Pannekoek' ' , University of Amsterdam, Science Park 904, 1098-XH Amsterdam (Netherlands); Homan, J., E-mail: ecackett@wayne.edu [Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, 70 Vassar Street, Cambridge, MA 02139 (United States)

    2013-09-10

    The quasi-persistent neutron star low-mass X-ray binary MXB 1659-29 went into quiescence in 2001, and we have followed its quiescent X-ray evolution since. Observations over the first 4 yr showed a rapid drop in flux and temperature of the neutron star atmosphere, interpreted as cooling of the neutron star crust which had been heated during the 2.5 yr outburst. However, observations taken approximately 1400 and 2400 days into quiescence were consistent with each other, suggesting the crust had reached thermal equilibrium with the core. Here we present a new Chandra observation of MXB 1659-29 taken 11 yr into quiescence and 4 yr since the last Chandra observation. This new observation shows an unexpected factor of {approx}3 drop in count rate and change in spectral shape since the last observation, which cannot be explained simply by continued cooling. Two possible scenarios are that either the neutron star temperature has remained unchanged and there has been an increase in the column density, or, alternatively the neutron star temperature has dropped precipitously and the spectrum is now dominated by a power-law component. The first scenario may be possible given that MXB 1659-29 is a near edge-on system, and an increase in column density could be due to build-up of material in, and a thickening of, a truncated accretion disk during quiescence. But, a large change in disk height may not be plausible if standard accretion disk theory holds during quiescence. Alternatively, the disk may be precessing, leading to a higher column density during this latest observation.

  11. Space-time structure of neutron and X-ray sources in a plasma focus

    International Nuclear Information System (INIS)

    Bostick, W.H.; Nardi, V.; Prior, W.

    1977-01-01

    Systematic measurements with paraffin collimators of the neutron emission intensity have been completed on a plasma focus with a 15-20 kV capacitor bank (hollow centre electrode; discharge period T approximately 8 μs; D 2 filling at 4-8 torr). The space resolution was 1 cm or better. These data indicate that at least 70% of the total neutron yield originates within hot-plasma regions where electron beams and high-energy D beams (approximately > 0.1-1 MeV) are produced. The neutron source is composed of several (approximately > 1-10) space-localized sources of different intensity, each with a duration approximately less than 5 ns (FWHM). Localized neutron sources and hard (approximately > 100 keV) X-ray sources have the same time multiplicity and are usually distributed in two groups over a time interval 40-400 ns long. By the mode of operation used by the authors one group of localized sources (Burst II) is observed 200-400 ns after the other group (Burst I) and its space distribution is broader than for Burst I. The maximum intensity of a localized source of neutrons in Burst I is much higher than the maximum intensity in Burst II. Secondary reactions T(D,n) 4 He (from the tritium produced only by primary reactions in the same discharge; no tritium was used in filling the discharge chamber) are observed in a time coincidence with the strongest D-D neutron pulse of Burst I. The neutron signal from a localized source with high intensity has a relatively long tail of small amplitude (area tail approximately less than 0.2 X area peak). This tail can be generated by the D-D reactions of the unconfined part of an ion beam in the cold plasma. Complete elimination of scattered neutrons on the detector was achieved in these measurements. (author)

  12. New methods of X-ray diffraction spectrometry. II

    International Nuclear Information System (INIS)

    Soerum, H.; Bremer, J.

    1980-01-01

    The construction principles for a flexible X-ray spectrometer can be equipped either with a single curved crystal or with two curved crystals are described. A few of the theoretical 4+32 possible working modes are selected for a closer investigation and examples of recorded spectra are given. It is shown in the general single-crystal case that for a wavelength close to a cut-off energy the narrow diffraction cone has an elliptic section, as predicted by the theory. The spectrometer is discussed in terms of intensity, resolution and dispersive power. A comparison with other types of spectrometer is made. (Auth.)

  13. X-ray topographic method of investigation of phase objects

    International Nuclear Information System (INIS)

    Levonyan, L.V.

    2001-01-01

    The intensity distribution of the monochromatized synchrotron radiation transmitting through the phase object and crystal-analyzer in Laue geometry is considered. It is shown that the local angular deviation of the incident radiation caused by the refraction on structural inhomogeneities of the object under investigation is directly transferred to the X-ray topographic image. In the absence of the phase object the latter consists of parallel straight fringes with a slowly decreasing period. The presence of the phase object changes the shape and period of fringes. The influence of the spatial and temporal coherence on the image is discussed. 5 refs

  14. Structure of zinc and niobium tellurite glasses by neutron and x-ray diffraction

    International Nuclear Information System (INIS)

    Hoppe, U; Yousef, E; Ruessel, C; Neuefeind, J; Hannon, A C

    2004-01-01

    Neutron and x-ray diffraction experiments of high resolving power with neutrons from a spallation source and high-energy photons from a synchrotron have been performed on compositional series of binary Zn, Nb and on mixed Zn/Nb tellurite glasses. The Te-O, Zn-O and Nb-O coordination numbers are determined by Gaussian fitting of the first-neighbour peaks in the neutron and x-ray data simultaneously. The transition of TeO 4 to TeO 3 units with increasing fraction of a second component is indicated by decreasing total Te-O coordination numbers. This transition appears different for glasses with ZnO or Nb 2 O 5 additions. Details of the Te-O peaks suggest there are two species of Te-O bonds with lengths of ∼ 0.19 and ∼ 0.21 nm. The change of their fractions shows excellent agreement with the existence of TeO 4 trigonal bipyramids and TeO 3 trigonal pyramids. All oxygen atoms from ZnO and Nb 2 O 5 are used for rupture of Te-O-Te bridges, which is accompanied with a change of nearly all participating TeO 4 to TeO 3 groups. The tendency for a TeO 4 → TeO 3 change decreases for glasses of higher second component content which is accompanied by the occurrence of TeO 4 groups with non-bridging oxygens. The Nb tellurite glasses show transition to network-forming behaviour with the formation of Nb-O-Nb bridges. The fractions of TeO 3 units of ternary Zn/Nb tellurite glasses agree with an additivity behaviour of the modifying effects of ZnO and Nb 2 O 5 additions

  15. The determination of the crystal structures of some uranium compounds by means of x-ray and neutron diffraction

    International Nuclear Information System (INIS)

    Adrian, H.W.W.

    1977-10-01

    In industrial uranium processing or reprocessing procedures, aqueous uranyl nitrate solutions are an intermediate product. The compounds, whose structures are reported, might prove valuable as alternative crystallization products to existing methods of extracting the uranium from solution. The compounds are obtained by the addition of hydroxylammonium to the uranyl nitrate solution and are of the general formula UO 2 (NH 2 0) 2 .xH 2 0, where x can take the values zero, two, three and four. In addition a compound of the formula UO 2 (NH 2 0) 2 .2(NH 2 CH).2H 2 0 was obtained. The UO 2 (NH 2 0) compound crystallized in a monoclinic crystal form. Crystals large enough for neutron diffraction were not obtained. The structure of the UO 2 (NH 2 0) 2 .2H 2 0 could not be solved because only disordered crystalline material was available. The structure of UO 2 (NH 2 0) 2 .3H 2 0 was solved by means of room- and low-temperature neutron diffraction. The unit cell is orthorhombic. The structure of α-UO 2 (NH 2 0) 2 .4H 2 0 was investigated by means of room-temperature x-ray and room- and low-temperature neutron diffraction. The unit cell is triclinic. This compound strongly resembles the trihydrate. The UO 2 (NH 2 0) 2 .2(NH 2 0H).2H 2 0 compound gave crystals large enough for single crystal x-ray but not neutron diffraction. The unit cell is orthorhombic. The characteristic powder patterns (indexed except for the dihydrate compound) of the above compounds are reported [af

  16. Water penetration mechanisms in nuclear glasses by X-ray and neutron reflectometry

    International Nuclear Information System (INIS)

    Rebiscoul, D.; Rieutord, F.; Ne, F.; Frugier, P.; Gin, S.; Cubitt, R.

    2007-01-01

    To determine the water diffusion at the early stage of the alteration, X-ray and neutron reflectometry have been performed on altered simplified glasses and the SON68 glass (an inactive R7T7-type French nuclear glass). For the first experiment, the simplified and SON68 glasses were altered at pH 3 and pH 6 and characterized by X-ray reflectometry as a function of the alteration duration. The evolutions of the electron density profile obtained from the reflectivity curves simulations have allowed the determination of the layers compositions. At the beginning of the alteration and for pH 3, the altered surface layer is constituted of a dealkalized zone. Upon alteration progress, the water diffuses inside the layer and hydrolyzes the Si-O-B bonds. For the second experiment, glasses were altered in D 2 O (pD 3) and analyzed in D 2 O saturated cell. After a D 2 O/H 2 O substitution, the samples were characterized one more time in H 2 O saturated cell. The evolution of the scattering length density shows that in the first stage of the alteration, the layer is constituted of two parts: a dealkalized glass and a dealkalized and boron depleted glass where water has diffused. According to the glass composition and after few hours of alteration, this dealkalized glass part can disappear. (authors)

  17. Contrasting Behaviour from Two Be/X-ray Binary Pulsars: Insights into Differing Neutron Star Accretion Modes

    Science.gov (United States)

    Townsend, L. J.; Drave, S. P.; Hill, A. B.; Coe, M. J.; Corbet, R. H. D.; Bird, A. J.

    2013-01-01

    In this paper we present the identification of two periodic X-ray signals coming from the direction of the Small Magellanic Cloud (SMC). On detection with the Rossi X-ray Timing Explorer (RXTE), the 175.4 s and 85.4 s pulsations were considered to originate from new Be/X-ray binary (BeXRB) pulsars with unknown locations. Using rapid follow-up INTEGRAL and XMM-Newton observations, we show the first pulsar (designated SXP175) to be coincident with a candidate high-mass X-ray binary (HMXB) in the northern bar region of the SMC undergoing a small Type II outburst. The orbital period (87d) and spectral class (B0-B0.5IIIe) of this system are determined and presented here for the first time. The second pulsar is shown not to be new at all, but is consistent with being SXP91.1 - a pulsar discovered at the very beginning of the 13 year long RXTE key monitoring programme of the SMC. Whilst it is theoretically possible for accreting neutron stars to change spin period so dramatically over such a short time, the X-ray and optical data available for this source suggest this spin-up is continuous during long phases of X-ray quiescence, where accretion driven spin-up of the neutron star should be minimal.

  18. Measurement of thickness of thin films by the X-ray diffraction method

    International Nuclear Information System (INIS)

    Srinivasan, C.; Balasingh, C.; Singh, A.K.

    1979-07-01

    X-ray diffraction method can be used to measure the thickness of thin films (coatings). The principle and the experimental details of the x-ray diffraction methods are described. The intensities of the diffracted beams are derived assuming a random orientation of the crystallites in the diffracting medium. Consequently, the expressions are not valid when the sample has preferred orientation. To check the performance of the method, thicknesses of nickel deposits on mild steel plates were determined by the x-ray diffraction method and the results compared with those obtained by the weighing method and metallographic examination. The weighing method which gives an accuracy of +- 0.1 micron is taken as the standard. The x-ray diffraction methods and the metallographic examinations give values within +- 1 micron of the value obtained by the weighing method. (author)

  19. X-ray methods for the chemical characterization of atmospheric aerosols

    International Nuclear Information System (INIS)

    Jaklevic, J.M.; Thompson, A.C.

    1981-05-01

    The development and use of several x-ray methods for the chemical characterization of atmospherical aerosol particulate samples are described. These methods are based on the emission, absorption, and scattering of x-ray photons with emphasis on the optimization for the non-destructive analysis of dilute specimens. Techniques discussed include photon induced energy dispersive x-ray fluorescence, extended x-ray absorption fine structure spectroscopy using synchrotron radiation and high-rate x-ray powder diffractometry using a position-sensitive gas proportional counter. These x-ray analysis methods were applied to the measurement of the chemical compositions of size-segregated aerosol particulate samples obtained with dichotomous samplers. The advantages of the various methods for use in such measurements are described and results are presented. In many cases, the complementary nature of the analytical information obtained from the various measurements is an important factor in the characterization of the sample. For example, the multiple elemental analyses obtained from x-ray fluorescence can be used as a cross check on the major compounds observed by powder diffraction

  20. Improved analytical formulas for x-ray and neutron reflection from surface films

    International Nuclear Information System (INIS)

    Zhou, X.; Chen, S.; Felcher, G.P.

    1992-01-01

    A general and exact expression for x-ray and neutron reflectance and transmittance is given in terms of an integral of the real-space scattering-length-density profile fluctuation of the film, with respect to an arbitrary constant reference density level, over the wave function inside the film. Various special cases and approximations are then derived from this exact form by suitable approximations of the wave function. In particular, two practical approximate formulas are derived which are improvement over the corresponding distorted-wave Born approximations. One is for an arbitrary film deposited on a known substrate and the other for a free liquid surface. Numerical results are used to illustrate the accuracy of these formulas

  1. X-ray and neutron diffraction determination of residual stresses in a pressed and welded component

    International Nuclear Information System (INIS)

    Albertini, G.; Broda, M.; Fiori, F.; Girardin, E.; Giuliani, A.; Quadrini, E.

    1999-01-01

    Complete text of publication follows. Problems connected with welding and pressing are very important in mechanical design, as these processed create microstructural alterations and internal stresses in the material that cannot be neglected. A pressing steel (FEP13) machine element is considered, designed to support a scooter engine. Two kinds of fatigue are to be supported by the component during operation: high loads at low frequency, due to the interaction of the scooter with the soil and low loads at high frequency due to the engine. The knowledge of the residual stress field occurring before operation is fundamental in order to perform theoretical predictions of the stress state during operation, and also to determine the loads to be used in fatigue tests which the component will be submitted to. The results of X-ray and neutron experiments are presented, carried out across a 'critical' weld in the component. (author)

  2. Excitation of Neutron Star f-mode in Low Mass X-ray Binaries

    International Nuclear Information System (INIS)

    Araujo, J C N de; Miranda, O D; Aguiar, O D

    2006-01-01

    Neutron Stars (NSs) present a host of pulsation modes. Only a few of them, however, is of relevance from the gravitational wave (GW) point of view. Among the various possible modes the pulsation energy is mostly stored in the f-mode in which the fluid parameters undergo the largest changes. An important question is how the pulsation modes are excited in NSs. Here we consider the excitation of the f-mode in the accreting NSs belonging to Low Mass X-ray Binaries (LMXBs), which may well be a recurrent source of GWs, since the NSs are continuously receiving matter from their companion stars. We also discuss the detectability of the GWs for the scenario considered here

  3. In situ X-ray and neutron diffraction study of Ba2In2O5

    International Nuclear Information System (INIS)

    Speakman, S.A.; Misture, S.T.

    2001-01-01

    Order-disorder transitions in barium indate, Ba 2 In 2 O 5 , have been studied using in-situ X-ray and neutron diffraction. At room temperature, the crystal structure is an orthorhombic brownmillerite structure. At 706 C, the crystal structure is orthorhombic, possibly of the Imma or Ibm2 space groups. At 900 C, oxygen vacancies begin to disorder. The order-disorder transition occurs slowly in two steps over a temperature range of 900 - 925 C. Above this temperature range, the crystal structure is tetragonal, most likely belonging to the space group I 4/mcm. A second order-disorder transition begins at 1040 C, and proceeds over the temperature range 1040 - 1065 C. Above this temperature range, the crystal structure is a cubic, oxygen-deficient perovskite structure, with space group Pm3m. At an undetermined temperature above 1200 C, Ba 2 In 2 O 5 begins to decompose. (orig.)

  4. Adapting an x-ray/debris shield to the cascade ICF power plant: Neutronics issues

    International Nuclear Information System (INIS)

    Tobin, M.T.

    1990-01-01

    A neutronics analysis has been carried out to determine the effects on the Cascade ICF reactor concept of adding a solid-lithium x-ray and debris shield to each ICF capsule. Results indicate that tritium breeding in LiAlO 2 is possible with a modest isotopic enhancement in 6 Li (to 15%). The shallow-burial index is greater than 1 (indicating that deep burial may be required) if the blanket is kept in the reactor for more than 2.5 yr. Nine percent of the total thermal power is unrecoverable. Parts of the chamber wall may require replacement once during the reactor life due to radiation damage. Part of the SiC chamber end cap must be replaced annually. The reactor may not require any nuclear-grade construction. 20 refs., 4 figs., 3 tabs

  5. Computed tomography of x-ray index of refraction using the diffraction enhanced imaging method

    International Nuclear Information System (INIS)

    Dilmanian, F.A.; Ren, B.; Wu, X.Y.; Orion, I.; Zhong, Z.; Thomlinson, W.C.; Chapman, L.D.

    2000-01-01

    Diffraction enhanced imaging (DEI) is a new, synchrotron-based, x-ray radiography method that uses monochromatic, fan-shaped beams, with an analyser crystal positioned between the subject and the detector. The analyser allows the detection of only those x-rays transmitted by the subject that fall into the acceptance angle (central part of the rocking curve) of the monochromator/analyser system. As shown by Chapman et al , in addition to the x-ray attenuation, the method provides information on the out-of-plane angular deviation of x-rays. New images result in which the image contrast depends on the x-ray index of refraction and on the yield of small-angle scattering, respectively. We implemented DEI in the tomography mode at the National Synchrotron Light Source using 22 keV x-rays, and imaged a cylindrical acrylic phantom that included oil-filled, slanted channels. The resulting 'refraction CT image' shows the pure image of the out-of-plane gradient of the x-ray index of refraction. No image artefacts were present, indicating that the CT projection data were a consistent set. The 'refraction CT image' signal is linear with the gradient of the refractive index, and its value is equal to that expected. The method, at the energy used or higher, has the potential for use in clinical radiography and in industry. (author)

  6. High-speed X-ray phase tomography with Talbot interferometer and fringe scanning method

    International Nuclear Information System (INIS)

    Kibayashi, Shunsuke; Harasse, Sébastien; Yashiro, Wataru; Momose, Atsushi

    2012-01-01

    High-speed X-ray phase tomography based on the Fourier-transform method has been demonstrated with an X-ray Talbot interferometer using white synchrotron radiation. We report the experimental results of high-speed X-ray phase tomography with fringe-scanning method instead of Fourier-transform method to improve spatial resolution without a considerable increase of scan time. To apply fringe-scanning method to high speed tomography, we tested a scan that is a synchronous combination of one-way continuous movements of the sample rotation and the grating displacement. When this scanning method was combined with X-ray phase tomography, we were able to obtain a scan time of 5 s. A comparison of the image quality derived with the conventional approach and with the proposed approach using the fringe-scanning method showed that the latter had better spatial resolution.

  7. Measuring neutron fluences and gamma/x-ray fluxes with CCD cameras

    International Nuclear Information System (INIS)

    Yates, G.J.; Smith, G.W.; Zagarino, P.; Thomas, M.C.

    1991-01-01

    The capability to measure bursts of neutron fluences and gamma/x-ray fluxes directly with charge coupled device (CCD) cameras while being able to distinguish between the video signals produced by these two types of radiation, even when they occur simultaneously, has been demonstrated. Volume and area measurements of transient radiation-induced pixel charge in English Electric Valve (EEV) Frame Transfer (FT) charge coupled devices (CCDs) from irradiation with pulsed neutrons (14 MeV) and Bremsstrahlung photons (4--12 MeV endpoint) are utilized to calibrate the devices as radiometric imaging sensors capable of distinguishing between the two types of ionizing radiation. Measurements indicate ∼.05 V/rad responsivity with ≥1 rad required for saturation from photon irradiation. Neutron-generated localized charge centers or ''peaks'' binned by area and amplitude as functions of fluence in the 10 5 to 10 7 n/cm 2 range indicate smearing over ∼1 to 10% of CCD array with charge per pixel ranging between noise and saturation levels

  8. Hard X-ray bursts and DD microfusion neutrons from complex ...

    Indian Academy of Sciences (India)

    explosive destruction of micrograins is accompanied by X-ray radiation (during hydrody- ... makes it possible to produce lasing in hard X-rays due to the effects of multiple scattering ... portant, information on the X-ray random media, including some indirect diagnostics. In ... stages of ionization in the total flux of particles.

  9. Investigation of polydisperse, disordered, and fractal systems by small-angle x-ray and neutron scattering

    International Nuclear Information System (INIS)

    Schmidt, P.W.; Tang, Y.; Roell, A.; Steiner, M.; Hoehr, A.; Neumann, H.B.

    1990-01-01

    Small-angle x-ray and neutron scattering are useful methods for investigating the structure of materials on a scale from about 10 to 2000 A. Some experimental procedures and methods of data analysis for small-angle scattering are outlined, and the use of small-angle scattering for studies of polydisperse systems (i.e., systems of particles of different size) of independently scattering particles is reviewed. Some general properties of the small-angle scattering from mass and surface fractals are discussed, and some applications of these concepts in recent experimental studies are presented. Results obtained in calculations of the small-angle scattering from a model of a surface are summarized. (author) 3 figs., 18 refs

  10. Combined Neutron and X-Ray Radiographic/Tomographic Analysis of Dissolution Limestones under Acidic Conditions

    Science.gov (United States)

    Anovitz, L. M.; Cole, D. R.; Hussey, D. S.; LaManna, J.; Swift, A.; Jacobson, D. L.

    2016-12-01

    Carbon dioxide capture and sequestration in deep geological formations is an important option for reducing greenhouse gas emissions. While the importance of porosity and pore-evolution has long been recognized, the evolution of porosity and permeability in reactive carbonates exposed to CO2-loaded brines is not well constrained. A typical pH range for CO2-acidified brine is 3 to 4.5 depending on alkalinity. This represents a substantial perturbation of typical brines that range from pH 6 to 8. The key questions include how accessible are the pores to fluid transport and how does the pore network evolve as the matrix reacts with the acidic solution? Limestones and dolostones contain nano- to macroscale porosity comprised of cracks, grain boundaries, fluid inclusions, single pores, vugs and networks of pores of random shapes and orientations. Accessible, interconnected pores may act as pore throats, constraining overall flow and are the most likely locations for extensive rock alteration. Neutron imaging is well suited to interrogation of fluid flow in porous media. Because of the large scattering cross section of hydrogen it can be used to directly image water or hydrocarbons without an added contrast medium that might modify interfacial tension and fluid/fluid interactions. In order to understand the reaction of acidified fluids we used simultaneous neutron and X-ray tomography to study the uptake and reaction of water and an acidic fluid (pH 1 HCl) with two types of Indiana limestone, one with a permeability of 2-4 mD, and the other 70 mD. One set of experiments explored capillary uptake in a dry core. These documented rapid uptake and CO2 bubble formation at the inlet. A second set introduced at a constant forced flow rate of 10 ml/min. Both core types exhibited wormhole formation, but the low perm limestone wormhole consisted of one well-delineated channel with a few side "tributaries," whereas the high perm core exhibited a more diffuse array of channels. Post

  11. Correction method and software for image distortion and nonuniform response in charge-coupled device-based x-ray detectors utilizing x-ray image intensifier

    International Nuclear Information System (INIS)

    Ito, Kazuki; Kamikubo, Hironari; Yagi, Naoto; Amemiya, Yoshiyuki

    2005-01-01

    An on-site method of correcting the image distortion and nonuniform response of a charge-coupled device (CCD)-based X-ray detector was developed using the response of the imaging plate as a reference. The CCD-based X-ray detector consists of a beryllium-windowed X-ray image intensifier (Be-XRII) and a CCD as the image sensor. An image distortion of 29% was improved to less than 1% after the correction. In the correction of nonuniform response due to image distortion, subpixel approximation was performed for the redistribution of pixel values. The optimal number of subpixels was also discussed. In an experiment with polystyrene (PS) latex, it was verified that the correction of both image distortion and nonuniform response worked properly. The correction for the 'contrast reduction' problem was also demonstrated for an isotropic X-ray scattering pattern from the PS latex. (author)

  12. Quantitative method of X-ray diffraction phase analysis of building materials

    International Nuclear Information System (INIS)

    Czuba, J.; Dziedzic, A.

    1978-01-01

    Quantitative method of X-ray diffraction phase analysis of building materials, with use of internal standard, has been presented. The errors committed by determining the content of particular phases have been also given. (author)

  13. Method for detecting binding events using micro-X-ray fluorescence spectrometry

    Science.gov (United States)

    Warner, Benjamin P.; Havrilla, George J.; Mann, Grace

    2010-12-28

    Method for detecting binding events using micro-X-ray fluorescence spectrometry. Receptors are exposed to at least one potential binder and arrayed on a substrate support. Each member of the array is exposed to X-ray radiation. The magnitude of a detectable X-ray fluorescence signal for at least one element can be used to determine whether a binding event between a binder and a receptor has occurred, and can provide information related to the extent of binding between the binder and receptor.

  14. Further comments on the effects of vacuum birefringence on the polarization of X-rays emitted from magnetic neutron stars

    Science.gov (United States)

    Chanan, G. A.; Novick, R.; Silver, E. H.

    1979-01-01

    The birefringence of the vacuum in the presence of strong (of the order of 1 teragauss) magnetic fields will in general affect the polarization of X-rays propagating through these fields. Two of the four Stokes parameters will vary so rapidly with wavelength as to be 'washed out' and unobservable, but the remaining two parameters will be unaffected. These results show that one conclusion of an earlier work is incorrect: Polarized X-ray emission from the surface of a magnetic neutron star will not in general be completely depolarized by the effects of vacuum birefringence. In particular, this birefringence has no effect on the linear polarization of cyclotron emission from the poles of magnetic neutron stars, and a similar result holds for synchrotron emission. More general cases of the propagation of polarized X-rays in magnetic fields are also discussed.

  15. Use of the maximum entropy method in X-ray astronomy

    International Nuclear Information System (INIS)

    Willingale, R.

    1981-01-01

    An algorithm used to apply the maximum entropy method in X-ray astronomy is described. It is easy to programme on a digital computer and fast enough to allow processing of two-dimensional images. The method gives good noise suppression without loss of instrumental resolution and has been successfully applied to several data analysis problems in X-ray astronomy. The restoration of a high-resolution image from the Einstein Observatory demonstrates the use of the algorithm. (author)

  16. Determination of chlorine in coal by X-ray fluorescence spectrometry method

    Energy Technology Data Exchange (ETDEWEB)

    Marek, S.; Bojarska, K. [Central Mining Institute, Katowice (Poland). Dept. of Environmental Monitoring

    1997-12-31

    Determination of chlorine contents in coal is essential for both environmental protection and its technological use. The existing method of chlorine determination in coal are titration methods which have considerable errors particularly in the low concentration range. The elaborated method with the use of X-ray fluorescence spectrometry in a comparison to the other methods is much faster and has better precision and accuracy. The principle of the method lies in the measurement of X-ray fluorescence radiation intensity which is emitted by chlorine in a sample and its comparison with standards. The calibration of the elaborated XRF method is based on natural coals having various concentrations of chlorine within the whole range of its occurrence in Polish coals. Concentrations for the calibration purpose were obtained by the determination of chlorine contents in selected coals by atomic absorption spectrometry method. The procedure of sample preparation for direct X-ray measurements, instrumental measuring conditions and the way of calibration curve preparation are described in the paper. All X-ray measurements were done with a Phillips sequential X-ray fluorescence spectrometer. A double anode Cr-Au X-ray tube with maximum power 3000 MW was used as the excitation source. 5 figs., 4 tabs.

  17. Studies of oxide-based thin-layered heterostructures by X-ray scattering methods

    Energy Technology Data Exchange (ETDEWEB)

    Durand, O. [Thales Research and Technology France, Route Departementale 128, F-91767 Palaiseau Cedex (France)]. E-mail: olivier.durand@thalesgroup.com; Rogers, D. [Nanovation SARL, 103 bis rue de Versailles 91400 Orsay (France); Universite de Technologie de Troyes, 10-12 rue Marie Curie, 10010 (France); Teherani, F. Hosseini [Nanovation SARL, 103 bis rue de Versailles 91400 Orsay (France); Andrieux, M. [LEMHE, ICMMOCNRS-UMR 8182, Universite d' Orsay, Batiment 410, 91410 Orsay (France); Modreanu, M. [Tyndall National Institute, Lee Maltings, Prospect Row, Cork (Ireland)

    2007-06-04

    Some X-ray scattering methods (X-ray reflectometry and Diffractometry) dedicated to the study of thin-layered heterostructures are presented with a particular focus, for practical purposes, on the description of fast, accurate and robust techniques. The use of X-ray scattering metrology as a routinely working non-destructive testing method, particularly by using procedures simplifying the data-evaluation, is emphasized. The model-independent Fourier-inversion method applied to a reflectivity curve allows a fast determination of the individual layer thicknesses. We demonstrate the capability of this method by reporting X-ray reflectometry study on multilayered oxide structures, even when the number of the layers constitutive of the stack is not known a-priori. Fast Fourier transform-based procedure has also been employed successfully on high resolution X-ray diffraction profiles. A study of the reliability of the integral-breadth methods in diffraction line-broadening analysis applied to thin layers, in order to determine coherent domain sizes, is also reported. Examples from studies of oxides-based thin-layers heterostructures will illustrate these methods. In particular, X-ray scattering studies performed on high-k HfO{sub 2} and SrZrO{sub 3} thin-layers, a (GaAs/AlOx) waveguide, and a ZnO thin-layer are reported.

  18. Experimental determination of spin-dependent electron density by joint refinement of X-ray and polarized neutron diffraction data.

    Science.gov (United States)

    Deutsch, Maxime; Claiser, Nicolas; Pillet, Sébastien; Chumakov, Yurii; Becker, Pierre; Gillet, Jean Michel; Gillon, Béatrice; Lecomte, Claude; Souhassou, Mohamed

    2012-11-01

    New crystallographic tools were developed to access a more precise description of the spin-dependent electron density of magnetic crystals. The method combines experimental information coming from high-resolution X-ray diffraction (XRD) and polarized neutron diffraction (PND) in a unified model. A new algorithm that allows for a simultaneous refinement of the charge- and spin-density parameters against XRD and PND data is described. The resulting software MOLLYNX is based on the well known Hansen-Coppens multipolar model, and makes it possible to differentiate the electron spins. This algorithm is validated and demonstrated with a molecular crystal formed by a bimetallic chain, MnCu(pba)(H(2)O)(3)·2H(2)O, for which XRD and PND data are available. The joint refinement provides a more detailed description of the spin density than the refinement from PND data alone.

  19. Hydrogen bond nature of ferroelectric material studied by X-ray and neutron diffraction. Electric dipole moment and proton tunneling

    International Nuclear Information System (INIS)

    Noda, Yukio; Kiyanagi, Ryoji; Mochida, Tomoyuki; Sugawara, Tadashi

    2006-01-01

    Hydrogen bond nature of MeHPLN and BrHPLN is studied using x-ray and neutron diffraction technique. We found that electric dipole moment of hydrogen atom plays an important role for the phase transition, and proton tunneling model is confirmed on this isolated hydrogen bond system. (author)

  20. Hydrogen concentration and mass density of diamondlike carbon films obtained by x-ray and neutron reflectivity

    DEFF Research Database (Denmark)

    Findeisen, E.; Feidenhans'l, R.; Vigild, Martin Etchells

    1994-01-01

    Specular reflectivity of neutrons and x rays can be used to determine the scattering length density profile of a material perpendicular to its surface. We have applied these techniques to study amorphous, diamondlike, hydrocarbon films. By the combination of these two techniques we obtain not onl...

  1. Structure of zinc and niobium tellurite glasses by neutron and x-ray diffraction

    Science.gov (United States)

    Hoppe, U.; Yousef, E.; Rüssel, C.; Neuefeind, J.; Hannon, A. C.

    2004-03-01

    Neutron and x-ray diffraction experiments of high resolving power with neutrons from a spallation source and high-energy photons from a synchrotron have been performed on compositional series of binary Zn, Nb and on mixed Zn/Nb tellurite glasses. The Te-O, Zn-O and Nb-O coordination numbers are determined by Gaussian fitting of the first-neighbour peaks in the neutron and x-ray data simultaneously. The transition of TeO4 to TeO3 units with increasing fraction of a second component is indicated by decreasing total Te-O coordination numbers. This transition appears different for glasses with ZnO or Nb2O5 additions. Details of the Te-O peaks suggest there are two species of Te-O bonds with lengths of {\\sim }0.19 and {\\sim }0.21 nm. The change of their fractions shows excellent agreement with the existence of TeO4 trigonal bipyramids and TeO3 trigonal pyramids. All oxygen atoms from ZnO and Nb2O5 are used for rupture of Te-O-Te bridges, which is accompanied with a change of nearly all participating TeO4 to TeO3 groups. The tendency for a {\\mathrm {TeO}}_{4} \\to {\\mathrm {TeO}}_{3} change decreases for glasses of higher second component content which is accompanied by the occurrence of TeO4 groups with non-bridging oxygens. The Nb tellurite glasses show transition to network-forming behaviour with the formation of Nb-O-Nb bridges. The fractions of TeO3 units of ternary Zn/Nb tellurite glasses agree with an additivity behaviour of the modifying effects of ZnO and Nb2O5 additions. Some of these results have already been presented in thesis work: Yousef E 2003 A study of some physical properties of tellurite glass (Al-Azhar University, Assiut Egypt).

  2. Non-destructive investigation of a time capsule using neutron radiography and X-ray fluorescence

    Science.gov (United States)

    MacDonald, B. L.; Vanderstelt, J.; O'Meara, J.; McNeill, F. E.

    2016-01-01

    Non-destructive analytical techniques are becoming increasingly important for the study of objects of cultural heritage interest. This study applied two techniques: X-ray fluorescence and neutron radiography, for the investigation of a capped, tubular metal object recovered from an urban construction site in Gore Park, Hamilton, Canada. The site is an urban park containing a World War I commemorative monument that underwent renovation and relocation. Historical documentation suggested that the object buried underneath the monument was a time capsule containing a paper document listing the names of 1800 Canadians who died during WWI. The purpose of this study was to assess the condition of the object, and to verify if it was what the historical records purported. XRF analysis was used to characterize the elemental composition of the metal artifact, while neutron radiography revealed that its contents were congruent with historical records and remained intact after being interred for 91 years. Results of this study demonstrate the value of non-destructive techniques for the analysis and preservation of cultural heritage.

  3. Non-destructive investigation of a time capsule using neutron radiography and X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, B.L., E-mail: macdonbl@mcmaster.ca [McMaster University, Department of Medical Physics and Applied Radiation Sciences, Hamilton (Canada); Vanderstelt, J., E-mail: joshv@nray.ca [Nray Services Inc., 56A Head Street, Dundas, ON (Canada); O’Meara, J. [University of Guelph, Department of Physics, Guelph (Canada); McNeill, F.E. [McMaster University, Department of Medical Physics and Applied Radiation Sciences, Hamilton (Canada)

    2016-01-15

    Non-destructive analytical techniques are becoming increasingly important for the study of objects of cultural heritage interest. This study applied two techniques: X-ray fluorescence and neutron radiography, for the investigation of a capped, tubular metal object recovered from an urban construction site in Gore Park, Hamilton, Canada. The site is an urban park containing a World War I commemorative monument that underwent renovation and relocation. Historical documentation suggested that the object buried underneath the monument was a time capsule containing a paper document listing the names of 1800 Canadians who died during WWI. The purpose of this study was to assess the condition of the object, and to verify if it was what the historical records purported. XRF analysis was used to characterize the elemental composition of the metal artifact, while neutron radiography revealed that its contents were congruent with historical records and remained intact after being interred for 91 years. Results of this study demonstrate the value of non-destructive techniques for the analysis and preservation of cultural heritage.

  4. Self-assembled iron oxide nanoparticle multilayer: x-ray and polarized neutron reflectivity

    International Nuclear Information System (INIS)

    Mishra, D; Benitez, M J; Petracic, O; Badini Confalonieri, G A; Szary, P; Brüssing, F; Devishvili, A; Toperverg, B P; Zabel, H; Theis-Bröhl, K; Vorobiev, A; Konovalov, O; Paulus, M; Sternemann, C

    2012-01-01

    We have investigated the structure and magnetism of self-assembled, 20 nm diameter iron oxide nanoparticles covered by an oleic acid shell for scrutinizing their structural and magnetic correlations. The nanoparticles were spin-coated on an Si substrate as a single monolayer and as a stack of 5 ML forming a multilayer. X-ray scattering (reflectivity and grazing incidence small-angle scattering) confirms high in-plane hexagonal correlation and a good layering property of the nanoparticles. Using polarized neutron reflectivity we have also determined the long range magnetic correlations parallel and perpendicular to the layers in addition to the structural ones. In a field of 5 kOe we determine a magnetization value of about 80% of the saturation value. At remanence the global magnetization is close to zero. However, polarized neutron reflectivity reveals the existence of regions in which magnetic moments of nanoparticles are well aligned, while losing order over longer distances. These findings confirm that in the nanoparticle assembly the magnetic dipole–dipole interaction is rather strong, dominating the collective magnetic properties at room temperature. (paper)

  5. Structure of ionic liquid-water mixtures at interfaces: x-ray and neutron reflectometry studies

    International Nuclear Information System (INIS)

    Lauw, Yansen; Rodopoulos, Theo; Horne, Mike; Follink, Bart; Hamilton, Bill; Knott, Robert; Nelson, Andy

    2009-01-01

    Full text: Fundamental studies on the effect of water in ionic liquids are necessary since the overall performance of ionic liquids in many industrial applications is often hampered by the presence of water.[1] Based on this understanding, the surface and interfacial structures of 1-butyl-1methylpyrrolidinium trifluoromethylsulfonylimide [C4mpyr][NTf2] ionic liquid-water mixtures were probed using x-ray and neutron reflectometry techniques. At the gas-liquid surface, a thick cation+water layer was detected next to the phase boundary, followed by an increasing presence of anion towards the bulk. The overall thickness of the surface exhibits non-monotonic trends with an increasing water content, which explains similar phenomenological trends in surface tension reported in the literature.[2] At an electrified interface, the interfacial structure of pure ionic liquids probed by neutron reflectometry shows similar trends to those predicted by a mean-field model.[3] However, the presence of water within the electrical double-layer is less obvious, although it is widely known that water reduces electrochemical window of ionic liquids. To shed light on this issue, further studies are currently in progress.

  6. Self-assembled iron oxide nanoparticle multilayer: x-ray and polarized neutron reflectivity.

    Science.gov (United States)

    Mishra, D; Benitez, M J; Petracic, O; Badini Confalonieri, G A; Szary, P; Brüssing, F; Theis-Bröhl, K; Devishvili, A; Vorobiev, A; Konovalov, O; Paulus, M; Sternemann, C; Toperverg, B P; Zabel, H

    2012-02-10

    We have investigated the structure and magnetism of self-assembled, 20 nm diameter iron oxide nanoparticles covered by an oleic acid shell for scrutinizing their structural and magnetic correlations. The nanoparticles were spin-coated on an Si substrate as a single monolayer and as a stack of 5 ML forming a multilayer. X-ray scattering (reflectivity and grazing incidence small-angle scattering) confirms high in-plane hexagonal correlation and a good layering property of the nanoparticles. Using polarized neutron reflectivity we have also determined the long range magnetic correlations parallel and perpendicular to the layers in addition to the structural ones. In a field of 5 kOe we determine a magnetization value of about 80% of the saturation value. At remanence the global magnetization is close to zero. However, polarized neutron reflectivity reveals the existence of regions in which magnetic moments of nanoparticles are well aligned, while losing order over longer distances. These findings confirm that in the nanoparticle assembly the magnetic dipole-dipole interaction is rather strong, dominating the collective magnetic properties at room temperature.

  7. Accretion dynamics and polarized X-ray emission of magnetized neutron stars

    Science.gov (United States)

    Arons, Jonathan

    1991-01-01

    The basic ideas of accretion onto magnetized neutron stars are outlined. These are applied to a simple model of the structure of the plasma mound sitting at the magnetic poles of such a star, in which upward diffusion of photons is balanced by their downward advection. This steady flow model of the plasma's dynamical state is used to compute the emission of polarized X-raysfrom the optically thick, birefringent medium. The linear polarization of the continuum radiation emerging from the quasi-static mound is found to be as much as 40 percent at some rotation phases, but is insensitive to the geometry of the accretion flow. The role of the accretion shock, whose detailed polarimetric and spectral characteristics have yet to be calculated, is emphasized as the final determinant of the properties of the emerging X-rays. Some results describing the fully time dependent dynamics of the flow are also presented. In particular, steady flow onto a neutron star is shown to exhibit formation of 'photon bubbles', regions of greatly reduced plasma density filled with radiation which form and rise on millisecond time scale. The possible role of these complex structures in the flow for the formation of the emergent spectrum is briefly outlined.

  8. INTEGRAL finds renewed X-ray activity of the Neutron star X-ray transient SAX J1750.8-2900

    DEFF Research Database (Denmark)

    Sanchez-Fernandez, Celia; Chenevez, Jérôme; Kuulkers, Erik

    2015-01-01

    INTEGRAL Galactic bulge monitoring observations (ATel #438) on UT 13 September 2015 18:50-22:32 reveal renewed X-ray activity from the low-mass X-ray binary transient and Type I X-ray burster SAX J1750.8-2900 (IAU Circ. #6597). The last outburst from this source was reported in 2011 (ATels #3170,...

  9. Determinations of silicon and phosphorus in rice planted on a district of high incidence of amyotrophic lateral sclerosis by neutron activation and X-ray fluorescence analyses

    Energy Technology Data Exchange (ETDEWEB)

    Mizumoto, Yoshihiko; Ishikawa, Teruumi; Kusakabe, Toshio; Katsurayama, Kousuke (Kinki Univ., Higashi-Osaka, Osaka (Japan)); Iwata, Shiro

    1989-12-01

    Silicon and phosphorus contents in polished and unpolished rice planted on a district of high incidence of amyotrophic lateral sclerosis (ALS) have been determined by neutron activation and X-ray fluorescence methods, and compared with those from control areas. In the neutron activation analysis, {beta}-ray spectra of {sup 32}P produced by the {sup 31}P(n, {gamma}){sup 32}P reaction on polished and unpolished rice were measured with a low background {beta}-ray spectrometer. In the X-ray fluorescence analysis, characteristic X-ray were analyzed with a wavelength dispersive X-ray fluorescence spectrometer. Silicon contents in polished and unpolished rice from the ALS area are 42 {mu}g.g{sup -1} and 370 {mu}g.g{sup -1}, respectively, and the corresponding phosphorus contents are 1210 {mu}g.g{sup -1}, and 3370 {mu}g.g{sup -1}, respectively. The data for ALS area are equal to those for the control area within atandard deviation. (author).

  10. On the evaluation of X-ray diffraction experiments by the regularization method

    Energy Technology Data Exchange (ETDEWEB)

    Trubin, V.A.; Szasz, A. (Lab. of Surface and Interface Physics, Eoetvoes Univ., Budapest (Hungary))

    1991-05-16

    The characteristic property of diffractometers as the presence of occasional and systematic errors in measured patterns requires such an evaluation which is as informative as possible. This circumstance gives rise to the problem of optimal planning of the experiment. The X-ray diffraction optimization problem with application of the regularization method is studied. The proposal permits to determine more accurately the unknown true characteristics of the X-ray diffraction experiment. (orig.).

  11. On the evaluation of X-ray diffraction experiments by the regularization method

    International Nuclear Information System (INIS)

    Trubin, V.A.; Szasz, A.

    1991-01-01

    The characteristic property of diffractometers as the presence of occasional and systematic errors in measured patterns requires such an evaluation which is as informative as possible. This circumstance gives rise to the problem of optimal planning of the experiment. The X-ray diffraction optimization problem with application of the regularization method is studied. The proposal permits to determine more accurately the unknown true characteristics of the X-ray diffraction experiment. (orig.)

  12. Calibration method of the pulsed X-ray relative sensitivity for ST401 plastic scintillators

    International Nuclear Information System (INIS)

    Xie Hongwei; Song Guzhou; Wang Kuilu

    2011-01-01

    The relative sensitivity calibration method of the pulsed X-ray in ST401 plastic scintillator is presented. Experimental relative sensitivity calibrations of the plastic scintillators of different thicknesses from 1 mm to 50 mm are accomplished on the 'Chenguang' pulsed X-ray source and a Co radioactive source, The uncertainty of the calibration data is evaluated, which can be treated as the experimental evidence for the relative sensitivity conversion of ST401 plastic scintillator. (authors)

  13. Detection of Reflection Features in the Neutron Star Low-mass X-Ray Binary Serpens X-1 with NICER

    DEFF Research Database (Denmark)

    Ludlam, R. M.; Miller, J. M.; Arzoumanian, Z.

    2018-01-01

    We present Neutron Star Interior Composition Explorer (NICER) observations of the neutron star (NS) low-mass X-ray binary Serpens X-1 during the early mission phase in 2017. With the high spectral sensitivity and low-energy X-ray passband of NICER, we are able to detect the Fe L line complex in a...

  14. Smoothed Particle Inference: A Kilo-Parametric Method for X-ray Galaxy Cluster Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, John R.; Marshall, P.J.; /KIPAC, Menlo Park; Andersson, K.; /Stockholm U. /SLAC

    2005-08-05

    We propose an ambitious new method that models the intracluster medium in clusters of galaxies as a set of X-ray emitting smoothed particles of plasma. Each smoothed particle is described by a handful of parameters including temperature, location, size, and elemental abundances. Hundreds to thousands of these particles are used to construct a model cluster of galaxies, with the appropriate complexity estimated from the data quality. This model is then compared iteratively with X-ray data in the form of adaptively binned photon lists via a two-sample likelihood statistic and iterated via Markov Chain Monte Carlo. The complex cluster model is propagated through the X-ray instrument response using direct sampling Monte Carlo methods. Using this approach the method can reproduce many of the features observed in the X-ray emission in a less assumption-dependent way that traditional analyses, and it allows for a more detailed characterization of the density, temperature, and metal abundance structure of clusters. Multi-instrument X-ray analyses and simultaneous X-ray, Sunyaev-Zeldovich (SZ), and lensing analyses are a straight-forward extension of this methodology. Significant challenges still exist in understanding the degeneracy in these models and the statistical noise induced by the complexity of the models.

  15. Preparation and characterization of a new set of IAEA reference air filters using instrumental neutron activation analysis, proton-induced X-ray emission and Rutherford backscattering

    Czech Academy of Sciences Publication Activity Database

    Kučera, Jan; Havránek, Vladimír; Krausová, Ivana

    2009-01-01

    Roč. 281, č. 1 (2009), s. 123-129 ISSN 0236-5731. [9th International Conference on Nuclear Analytical Methods in the Life Sciences. Lisbon, 07.09.2008-12.09.2008] Institutional research plan: CEZ:AV0Z10480505 Keywords : Reference air filters * instrumental neutron activation analysis * Proton induced X-ray emission Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 0.631, year: 2009

  16. Microstructural characterization of dental zinc phosphate cements using combined small angle neutron scattering and microfocus X-ray computed tomography

    Czech Academy of Sciences Publication Activity Database

    Viani, Alberto; Sotiriadis, Konstantinos; Kumpová, Ivana; Mancini, L.; Appavou, M.-S.

    2017-01-01

    Roč. 33, č. 4 (2017), s. 402-417 ISSN 0109-5641 R&D Projects: GA MŠk(CZ) LO1219 Keywords : zinc phosphate cements * small angle neutron scattering * X-ray micro-computed tomography * X-ray powder diffraction * zinc oxide * acid-base cements Subject RIV: JJ - Other Materials OBOR OECD: Composites (including laminates, reinforced plastics, cermets, combined natural and synthetic fibre fabrics Impact factor: 4.070, year: 2016 https://www.sciencedirect.com/science/article/pii/S0109564116305127

  17. The x-ray time of flight method for investigation of ghosting in amorphous selenium-based flat panel medical x-ray imagers

    International Nuclear Information System (INIS)

    Rau, A.W.; Bakueva, L.; Rowlands, J.A.

    2005-01-01

    Amorphous selenium (a-Se) based real-time flat-panel imagers (FPIs) are finding their way into the digital radiology department because they offer the practical advantages of digital x-ray imaging combined with an image quality that equals or outperforms that of conventional systems. The temporal imaging characteristics of FPIs can be affected by ghosting (i.e., radiation-induced changes of sensitivity) when the dose to the detector is high (e.g., portal imaging and mammography) or the images are acquired at a high frame rate (e.g., fluoroscopy). In this paper, the x-ray time-of-flight (TOF) method is introduced as a tool for the investigation of ghosting in a-Se photoconductor layers. The method consists of irradiating layers of a-Se with short x-ray pulses. From the current generated in the a-Se layer, ghosting is quantified and the ghosting parameters (charge carrier generation rate and carrier lifetimes and mobilities) are assessed. The x-ray TOF method is novel in that (1) x-ray sensitivity (S) and ghosting parameters can be measured simultaneously (2) the transport of both holes and electrons can be isolated, and (3) the method is applicable to the practical a-Se layer structure with blocking contacts used in FPIs. The x-ray TOF method was applied to an analysis of ghosting in a-Se photoconductor layers under portal imaging conditions, i.e., 1 mm thick a-Se layers, biased at 5 V/μm, were irradiated using a 6 MV LINAC x-ray beam to a total dose (ghosting dose) of 30 Gy. The initial sensitivity (S 0 ) of the a-Se layers was 63±2 nC cm -2 cGy -1 . It was found that S decreases to 30% of S 0 after a ghosting dose of 5 Gy and to 21% after 30 Gy at which point no further change in S occurs. At an x-ray intensity of 22 Gy/s (instantaneous dose rate during a LINAC x-ray pulse), the charge carrier generation rate was 1.25±0.1x10 22 ehp m -3 s -1 and, to a first approximation, independent of the ghosting dose. However, both hole and electron transport showed a

  18. Self-assembly behavior of discotic liquid crystals studied by neutron and X-ray scattering

    International Nuclear Information System (INIS)

    Kim, Hyo Sik

    2011-02-01

    We investigate both thermotropic and lyotropic phase behaviors in DLC molecules with detailed structural analysis which was performed by scattering methods such as small angle neutron scattering (SANS) and grazing incidence x-ray scattering (GIXS) techniques. First, for the study of thermotropic phase behavior in DLC, uniaxially oriented and well-ordered cobalt octa(n-decylthio)porphyrazine (CoS10) molecules in thin-film was used as a model molecule. Second, the lyotropic phase behavior in DLC was studied using model system, hexa-n-dodecyl-hexa-peri-hexabenzocoronene (HBC-C12) in organic solvent (p-xylene). The method for uniaxially oriented and highly ordered columnar superstructure of CoS10 on a large area of substrate (3 cm x 3 cm) has been developed by using applied magnetic field (ca. 1.0 T) and surface interaction simultaneously. When spin-coated CoS10 thin film on an OTS-functionalized silicon substrate was cooled from its isotropic phase to liquid crystalline phase in the presence of an applied magnetic field, the CoS10 formed uniaxially oriented and 'edge-on' arrangement of columnar superstructures with their columnar directors perpendicular to the applied magnetic field. Grazing incidence x-ray scattering (GIXS) measurements showed that CoS10 columns form rectangular columnar packing with a tilted arrangement against the columnar axis (ca. 40 .deg.) in columns. The effects of film thickness on the columnar packing structure in supported thin-films of CoS10 have been investigated by the GISAXS technique, with magnetically aligned CoS10 films on OTS-functionalized substrates used as model systems. CoS10 columnar superstructures in thin-films with thicknesses ranging from 49 nm to 845 nm were uniaxially oriented with 'edge-on' arrangement using magnetic field and surface interaction. The orientational ordering of the columnar packing in the plane perpendicular to the applied magnetic field is strongly dependent on the film thickness. While it is damped by

  19. Evaluation of material properties of SiC particle reinforced aluminum alloy composite using neutron and X-ray diffraction

    International Nuclear Information System (INIS)

    Akiniwa, Yoshiaki; Machiya, Shutaro; Kimura, Hidehiko; Tanaka, Keisuke; Minakawa, Nobuaki; Morii, Yukio; Kamiyama, Takashi

    2006-01-01

    The phase stresses under loading in a monolithic aluminum alloy and an aluminum alloy reinforced with silicon carbide particles were measured by the neutron diffraction method. Under uniaxial loading, the longitudinal and transverse strains in each constituent phase were measured. The diffraction elastic constants for each diffraction plane were investigated as a function of the diffraction intensity by TOF. Single peak analysis was carried out for each diffraction profile. The measured results were compared with the theoretical micromechanical models such as the self-consistent and Mori-Tanaka method using the Eshelby theory (MTE). The accuracy of the elastic constant strongly depends on the diffraction intensity. In order to confirm the rule of mixture, the phase stress was measured by the X-ray method. The macrostress calculated by the rule of mixture agreed very well with the applied stress. Finally, fatigue damage was evaluated by the neutron method. The change of the full width at half maximum in the aluminum phase during fatigue is small. On the other hand, the value in the SiC phase increased steeply just before fracture

  20. The reduction methods of operator's radiation dose for portable dental X-ray machines.

    Science.gov (United States)

    Cho, Jeong-Yeon; Han, Won-Jeong

    2012-08-01

    This study was aimed to investigate the methods to reduce operator's radiation dose when taking intraoral radiographs with portable dental X-ray machines. Two kinds of portable dental X-ray machines (DX3000, Dexcowin and Rextar, Posdion) were used. Operator's radiation dose was measured with an 1,800 cc ionization chamber (RadCal Corp.) at the hand level of X-ray tubehead and at the operator's chest and waist levels with and without the backscatter shield. The operator's radiation dose at the hand level was measured with and without lead gloves and with long and short cones. The backscatter shield reduced operator's radiation dose at the hand level of X-ray tubehead to 23 - 32%, the lead gloves to 26 - 31%, and long cone to 48 - 52%. And the backscatter shield reduced operator's radiation dose at the operator's chest and waist levels to 0.1 - 37%. When portable dental X-ray systems are used, it is recommended to select X-ray machine attached with a backscatter shield and a long cone and to wear the lead gloves.

  1. Methods for reduction of scattered x-ray in measuring MTF with the square chart

    International Nuclear Information System (INIS)

    Hatagawa, Masakatsu; Yoshida, Rie

    1982-01-01

    A square wave chart has been used to measure the MTF of a screen-film system. The problem is that the scattered X-ray from the chart may give rise to measurement errors. In this paper, the authors proposed two methods to reduce the scattered X-ray: the first method is the use of a Pb mask and second is to provide for an air gap between the chart and the screen-film system. In these methods, the scattered X-ray from the chart was reduced. MTFs were measured by both of the new methods and the conventional method, and MTF values of the new methods were in good agreement while that of the conventional method was not. It was concluded that these new methods are able to reduce errors in the measurement of MTF. (author)

  2. The disc-jet coupling in the neutron star X-ray binary 4U 1728-34

    Science.gov (United States)

    Tudose, Valeriu; Tzioumis, Anastasios; Belloni, Tomaso; Altamirano, Diego; Linares, Manuel; Mendez, Mariano; Hiemstra, Beike

    2010-10-01

    The present radio proposal is part of a multi-wavelength campaign focused on the study of the accretion/ejection process in the neutron star X-ray binary system 4U 1728-34. Our intention is to study the behaviour of the inner part of the accretion disc as inferred from the X-ray observations of the Fe emission line and the kHz quasi-periodic oscillations, and to link it to the properties of the radio jet. To achieve this goal we request 5 × 11h of observing time with ATCA, scheduled at regular intervals in the period 2010 August 27- October 13, the visibility window of the granted X-ray observations with RXTE (PI: Mendez) and Suzaku (PI: Linares).

  3. Relative evaluation of neutron activation, X-ray fluorescence and spark source mass spectrometry for multielement analysis of geothermal waters

    International Nuclear Information System (INIS)

    Blommaert, W.; Vandelannoote, R.; Van't Dack, L.; Gijbels, R.; Van Grieken, R.

    1980-01-01

    To sulfide geothermal waters from the French Pyrenees region and bicarbonate and chloride waters from the French Vosges area, all of the following analysis techniques were applied in order to compose a broad inventory of trace elements: (1) for the dissolved metarial: neutron activation analysis after a freeze-drying step using a very short cycle, short cycle or long cycle, neutron activation after co-crystallization on 1-(2-pyridylazo)-2-naphthol (PAN) using a short cycle or long cycle, X-ray fluorescence after co-crystallization on PAN and spark source mass spectrometry after evaporation on graphite or preconcentration on PAN, and, (2) for the filtered or suspended material: neutron activation using a very short, short or long cycle and X-ray fluorescence. Altogether, on the average some 30 elements could be determined above the detection limit in solution and 15 in suspension. (author)

  4. Study of properties of chemically modified samples of halloysite mineral with X-ray fluorescence and X-ray powder diffraction methods

    International Nuclear Information System (INIS)

    Banaś, D.; Kubala-Kukuś, A.; Braziewicz, J.; Majewska, U.; Pajek, M.; Wudarczyk-Moćko, J.; Czech, K.; Garnuszek, M.; Słomkiewicz, P.; Szczepanik, B.

    2013-01-01

    Elemental and chemical composition of raw and activated samples of halloysite mineral using wavelength dispersive X-ray fluorescence (WDXRF), total reflection X-ray fluorescence (TXRF) and X-ray powder diffraction (XRPD) methods were determined. As the result, it has been shown that application of the complementary X-ray spectrometry techniques allows very precise observation of changes in composition of halloysite mineral samples caused by its chemical modifications. Sample preparation procedure and usability of the research methods applied are described in details. Procedure of activation of raw halloysite mineral samples by etching them in sulfuric acid of various concentrations has been described and discussed. The ability of the samples to adsorb lead from intentionally contaminated water was tested and confirmed. - Author-Highlights: • We measured elemental and chemical composition of raw and activated halloysite mineral samples. • We showed that X-ray techniques allow precise study of changes in the sample composition. • We describe procedure of activation of the samples by etching them in sulfuric acid. • We tested ability of halloysite mineral to absorb lead from contaminated water

  5. Searching for Exoplanets around X-Ray Binaries with Accreting White Dwarfs, Neutron Stars, and Black Holes

    Science.gov (United States)

    Imara, Nia; Di Stefano, Rosanne

    2018-05-01

    We recommend that the search for exoplanets around binary stars be extended to include X-ray binaries (XRBs) in which the accretor is a white dwarf, neutron star, or black hole. We present a novel idea for detecting planets bound to such mass transfer binaries, proposing that the X-ray light curves of these binaries be inspected for signatures of transiting planets. X-ray transits may be the only way to detect planets around some systems, while providing a complementary approach to optical and/or radio observations in others. Any planets associated with XRBs must be in stable orbits. We consider the range of allowable separations and find that orbital periods can be hours or longer, while transit durations extend upward from about a minute for Earth-radius planets, to hours for Jupiter-radius planets. The search for planets around XRBs could begin at once with existing X-ray observations of these systems. If and when a planet is detected around an X-ray binary, the size and mass of the planet may be readily measured, and it may also be possible to study the transmission and absorption of X-rays through its atmosphere. Finally, a noteworthy application of our proposal is that the same technique could be used to search for signals from extraterrestrial intelligence. If an advanced exocivilization placed a Dyson sphere or similar structure in orbit around the accretor of an XRB in order to capture energy, such an artificial structure might cause detectable transits in the X-ray light curve.

  6. Flux decay during thermonuclear X-ray bursts analysed with the dynamic power-law index method

    Science.gov (United States)

    Kuuttila, J.; Kajava, J. J. E.; Nättilä, J.; Motta, S. E.; Sánchez-Fernández, C.; Kuulkers, E.; Cumming, A.; Poutanen, J.

    2017-08-01

    The cooling of type-I X-ray bursts can be used to probe the nuclear burning conditions in neutron star envelopes. The flux decay of the bursts has been traditionally modelled with an exponential, even if theoretical considerations predict power-law-like decays. We have analysed a total of 540 type-I X-ray bursts from five low-mass X-ray binaries observed with the Rossi X-ray Timing Explorer. We grouped the bursts according to the source spectral state during which they were observed (hard or soft), flagging those bursts that showed signs of photospheric radius expansion (PRE). The decay phase of all the bursts were then fitted with a dynamic power-law index method. This method provides a new way of probing the chemical composition of the accreted material. Our results show that in the hydrogen-rich sources the power-law decay index is variable during the burst tails and that simple cooling models qualitatively describe the cooling of presumably helium-rich sources 4U 1728-34 and 3A 1820-303. The cooling in the hydrogen-rich sources 4U 1608-52, 4U 1636-536, and GS 1826-24, instead, is clearly different and depends on the spectral states and whether PRE occurred or not. Especially the hard state bursts behave differently than the models predict, exhibiting a peculiar rise in the cooling index at low burst fluxes, which suggests that the cooling in the tail is much faster than expected. Our results indicate that the drivers of the bursting behaviour are not only the accretion rate and chemical composition of the accreted material, but also the cooling that is somehow linked to the spectral states. The latter suggests that the properties of the burning layers deep in the neutron star envelope might be impacted differently depending on the spectral state.

  7. Ion, X-ray, UV and Neutron Microbeam Systems for Cell Irradiation.

    Science.gov (United States)

    Bigelow, A W; Randers-Pehrson, G; Garty, G; Geard, C R; Xu, Y; Harken, A D; Johnson, G W; Brenner, D J

    2010-08-08

    The array of microbeam cell-irradiation systems, available to users at the Radiological Research Accelerator Facility (RARAF), Center for Radiological Research, Columbia University, is expanding. The HVE 5MV Singletron particle accelerator at the facility provides particles to two focused ion microbeam lines: the sub-micron microbeam II and the permanent magnetic microbeam (PMM). Both the electrostatic quadrupole lenses on the microbeam II system and the magnetic quadrupole lenses on the PMM system are arranged as compound lenses consisting of two quadrupole triplets with "Russian" symmetry. Also, the RARAF accelerator is a source for a proton-induced x-ray microbeam (undergoing testing) and is projected to supply protons to a neutron microbeam based on the (7)Li(p, n)(7)Be nuclear reaction (under development). Leveraging from the multiphoton microscope technology integrated within the microbeam II endstation, a UV microspot irradiator - based on multiphoton excitation - is available for facility users. Highlights from radiation-biology demonstrations on single living mammalian cells are included in this review of microbeam systems for cell irradiation at RARAF.

  8. Crystal structure investigations on cation-substituted alums by X-ray and neutron diffraction

    International Nuclear Information System (INIS)

    Abdeen, A.M.

    1980-04-01

    The crystal structures of the three alums: NH 4 Al(SO 4 ) 2 .12H 2 O, (NH 3 CH 3 )Al(SO 4 ) 2 .12H 2 O and (NH 3 OH)Al(SO 4 ) 2 .12H 2 O have been determined from three-dimensional neutron diffraction data enhanced by X-ray diffraction when necessary. These compounds crystallize cubic in space group Pa3. The structures of the three alums exhibit partial occupancies of crystallographic sites for the NH 4 , (NH 3 CH 3 ) and (NH 3 OH) group atoms. This can be explained by a quantized rotation of the three groups around an axis perpendicular to the [111] direction. Some of the (SO 4 ) 2- groups in the NH 4 -alum are disordered with about 17% of the sulfate tetrahedra being in a reversed orientation around the sulfur atom. The disorder in (NH 3 CH 3 ) and (NH 3 OH)-alums is only 4,3% and 3.0% respectively. The atoms in the alum structures are held together by a system of hydrogen bonds between the water molecules and between the water molecules and the sulfate oxygen atoms. In these three structures there is a strong indication that shorter hydrogen bonds tend to be nearly linear. (orig.)

  9. Joint small-angle X-ray and neutron scattering data analysis of asymmetric lipid vesicles

    International Nuclear Information System (INIS)

    Eicher, Barbara; Heberle, Frederick A.; Marquardt, Drew T.

    2017-01-01

    Low- and high-resolution models describing the internal transbilayer structure of asymmetric lipid vesicles have been developed. These models can be used for the joint analysis of small-angle neutron and X-ray scattering data. The models describe the underlying scattering length density/electron density profiles either in terms of slabs or through the so-called scattering density profile, previously applied to symmetric lipid vesicles. Both models yield structural details of asymmetric membranes, such as the individual area per lipid, and the hydrocarbon thickness of the inner and outer bilayer leaflets. The scattering density profile model, however, comes at a cost of increased computational effort but results in greater structural resolution, showing a slightly lower packing of lipids in the outer bilayer leaflet of ~120 nm diameter palmitoyloleoyl phosphatidylcholine (POPC) vesicles, compared to the inner leaflet. Here, analysis of asymmetric dipalmitoyl phosphatidylcholine/POPC vesicles did not reveal evidence of transbilayer coupling between the inner and outer leaflets at 323 K,i.e.above the melting transition temperature of the two lipids.

  10. Vascular and epithelial damage in the lung of the mouse after X rays or neutrons

    International Nuclear Information System (INIS)

    Law, M.P.; Ahier, R.G.

    1989-01-01

    The response of the lung was studied in CFLP mice after exposure of the whole thorax to X rays (250 kVp) or cyclotron neutrons (16 MeV deuterons on Be, mean energy 7.5 MeV). To measure blood volume and leakage of plasma proteins, 51Cr-labeled red blood cells and 125I-albumin were injected intravenously and 24 h later lungs were lavaged via the trachea. Radioactivities in lung tissue and lavage fluid were determined to estimate the accumulation of albumin in the interstitial and alveolar spaces indicating damage to blood vessels and alveolar epithelium respectively. Function of type II pneumonocytes was assessed by the amounts of surfactant (assayed as lipid phosphorous) released into the lavage fluid. During the first 6 weeks, lavage protein and surfactant were increased, the neutron relative biological effectiveness (RBE) being unity. During pneumonitis at 12-24 weeks, surfactant levels were normal, blood volume was decreased, and both interstitial and alveolar albumin were increased. Albumin levels then decreased. At late times after exposure (42-64 weeks) alveolar albumin returned to normal but interstitial albumin was still slightly elevated. Values of RBE for changes in blood volume and interstitial and alveolar albumin at 15 weeks and for changes in blood volume and interstitial albumin at 46 weeks were 1.4, comparable with that for animal survival at 180 days. The results indicate that surfactant production is not critical for animal survival. They suggest that changes in blood vessels and alveolar epithelium occur during acute pneumonitis; epithelial repair follows but some vascular damage may persist. The time course of the changes in albumin levels did not correlate with increases in collagen biosynthesis which have been observed as early as 1 month after exposure and persist for up to 1 year

  11. Role of X-ray examination methods in the diagnosis of endophytic stomach carcinomas

    International Nuclear Information System (INIS)

    Gorshkov, A.N.; Akberov, R.F.

    1998-01-01

    Results of studying potentialities of radiographic methods in the diagnosis of stomach endophytic neoplasms (130 cases) are presented. All of patients were exposed to complex radiographic-endoscopic studies of stomach. X-ray computerized tomography is used as an additional method. It is shown that the complex approach to the diagnosis of endophytic neoplasms of stomach is necessary. Radiographic method is proposed to be used as an initial examination method. Endoscopic method with multiple biopsy is also used. X-ray computerized tomography is used for certain anatomic stomach section at the final stage [ru

  12. Integration of the ATHENA mirror modules: development of indirect and x-ray direct AIT methods

    Science.gov (United States)

    Vernani, Dervis; Blum, Steffen; Seure, Thibault; Bavdaz, Marcos; Wille, Eric; Schaeffer, Uwe; Lièvre, Nicolas; Nazeeruddin, Adeeb; Barrière, Nicolas M.; Collon, Maximilien J.; Cibik, Levent; Krumrey, Michael; Müller, Peter; Burwitz, Vadim

    2017-08-01

    Within the ATHENA optics technology plan, activities are on-going for demonstrating the feasibility of the mirror module Assembly Integration and Testing (AIT). Each mirror module has to be accurately attached to the mirror structure by means of three isostatic mounts ensuring minimal distortion under environmental loads. This work reports on the status of one of the two parallel activities initiated by ESA to address this demanding task. In this study awarded to the industrial consortium, the integration relies on opto-mechanical metrology and direct X-ray alignment. For the first or "indirect" method the X-ray alignment results are accurately referenced, by means of a laser tracking system, to optical fiducial targets mounted on the mirror modules and finally linked to the mirror structure coordinate system. With the second or "direct" method the alignment is monitored in the X-ray domain, providing figures of merit directly comparable to the final performance. The integration being designed and here presented, foresees combining the indirect method to the X-ray direct method. The characterization of the single mirror modules is planned at PTB's X-ray Parallel Beam Facility (XPBF 2.0) at BESSY II, and the integration and testing campaign at Panter. It is foreseen to integrate and test a demonstrator with two real mirror modules manufactured by cosine.

  13. Simulation study on unfolding methods for diagnostic X-rays and mixed gamma rays

    International Nuclear Information System (INIS)

    Hashimoto, Makoto; Ohtaka, Masahiko; Ara, Kuniaki; Kanno, Ikuo; Imamura, Ryo; Mikami, Kenta; Nomiya, Seiichiro; Onabe, Hideaki

    2009-01-01

    A photon detector operating in current mode that can sense X-ray energy distribution has been reported. This detector consists of a row of several segment detectors. The energy distribution is derived using an unfolding technique. In this paper, comparisons of the unfolding techniques among error reduction, spectrum surveillance, and neural network methods are discussed through simulation studies on the detection of diagnostic X-rays and gamma rays emitted by a mixture of 137 Cs and 60 Co. For diagnostic X-ray measurement, the spectrum surveillance and neural network methods appeared promising, while the error reduction method yielded poor results. However, in the case of measuring mixtures of gamma rays, the error reduction method was both sufficient and effective. (author)

  14. X-ray and neutron diffuse scattering in LiNbO3 from 38 to 1200 K

    International Nuclear Information System (INIS)

    Zotov, N.; Mayer, H.M.; Guethoff, F.; Hohlwein, D.

    1995-01-01

    A semi-quantitative description of X-ray and neutron diffuse scattering from congruent lithium niobate, LiNbO 3 , is given. The diffuse scattering is concentrated in three sets of diffuse planes perpendicular to the pseudo-cubic symmetry-related [221], [241] and [ anti 4 anti 21] directions and can be attributed to one-dimensional displacive and chemical disorder along these directions. The variation of the X-ray and neutron diffuse intensities with the scattering vector, as well as the comparison between X-ray and neutron data, indicate that more than one type of atom is involved. Temperature variations are followed from 38 to 1200 K. Different disorder models are discussed. The increase of the integrated intensities of the diffuse lines along the [0 1k 2l] * and [0 anti 1k 4l] * directions (i.e. sections of the diffuse planes) up to 800 K followed by a slight decrease at higher temperatures may be interpreted either by static disorder related to temperature-dependent variation of disorder/defect clusters or by dynamic disorder. Inelastic neutron scattering experiments do not show any anomaly of the transversal acoustic (TA) modes. (orig.)

  15. Method for calculating required shielding in medical x-ray rooms

    International Nuclear Information System (INIS)

    Karppinen, J.

    1997-10-01

    The new annual radiation dose limits - 20 mSv (previously 50 mSv) for radiation workers and 1 mSv (previously 5 mSv) for other persons - implies that the adequacy of existing radiation shielding must be re-evaluated. In principle, one could assume that the thicknesses of old radiation shields should be increased by about one or two half-value layers in order to comply with the new dose limits. However, the assumptions made in the earlier shielding calculations are highly conservative; the required shielding was often determined by applying the maximum high-voltage of the x-ray tube for the whole workload. A more realistic calculation shows that increased shielding is typically not necessary if more practical x-ray tube voltages are used in the evaluation. We have developed a PC-based calculation method for calculating the x-ray shielding which is more realistic than the highly conservative method formerly used. The method may be used to evaluate an existing shield for compliance with new regulations. As examples of these calculations, typical x-ray rooms are considered. The lead and concrete thickness requirements as a function of x-ray tube voltage and workload are also given in tables. (author)

  16. Method of producing a pseudo-color photograph with X-rays

    International Nuclear Information System (INIS)

    Tajima, Mataichi.

    1965-01-01

    Conventional black and white X-ray photography cannot simultaneously produce an image on photographic film of a subject having regions of high and low X-ray absorption due to the limitation of photographic density range, gradation and exposure tolerance. This invention records both regions as images of different colors on the same color photographic film. According to a method of this invention for making an X-ray pseudo-color photograph, the subject is directly irradiated by an X-ray beam emergent from an X-ray beam generator, and an X-ray permeation image of the subject is converted into and displayed as a visible light image by means of a fluorescent screen. In one aspect of this invention, there is used a color photographic film which has at least two kinds of sensitive and coloring layers exhibiting the same sensitivity. During the period in which the visible image is displayed, the film is exposed to the visible light in such a way that at least two color filters differing in color and density are successively interposed between the film and the fluorescent screen. In another aspect, a color photographic film is employed having at least two kinds of sensitive and coloring layers exhibiting different sensitivities. During the period in which the visible image is displayed, the film is exposed to visible light by sequentially interposing at least two color filters of different color but of equal density. In this manner, regions comparatively low in X-ray absorption, such as the lungs, and regions comparatively high in absorption, such as the heart, appear as, for example, a blue image and a red image on the color photographic film, respectively. (Takasuka, S.)

  17. Method of producing a pseudo-color photograph with X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Tajima, M

    1965-05-08

    Conventional black and white X-ray photography cannot simultaneously produce an image on photographic film of a subject having regions of high and low X-ray absorption due to the limitation of photographic density range, gradation and exposure tolerance. This invention records both regions as images of different colors on the same color photographic film. According to a method of this invention for making an X-ray pseudo-color photograph, the subject is directly irradiated by an X-ray beam emergent from an X-ray beam generator, and an X-ray permeation image of the subject is converted into and displayed as a visible light image by means of a fluorescent screen. In one aspect of this invention, there is used a color photographic film which has at least two kinds of sensitive and coloring layers exhibiting the same sensitivity. During the period in which the visible image is displayed, the film is exposed to the visible light in such a way that at least two color filters differing in color and density are successively interposed between the film and the fluorescent screen. In another aspect, a color photographic film is employed having at least two kinds of sensitive and coloring layers exhibiting different sensitivities. During the period in which the visible image is displayed, the film is exposed to visible light by sequentially interposing at least two color filters of different color but of equal density. In this manner, regions comparatively low in X-ray absorption, such as the lungs, and regions comparatively high in absorption, such as the heart, appear as, for example, a blue image and a red image on the color photographic film, respectively.

  18. A model independent method to deconvolve hard X-ray spectra

    International Nuclear Information System (INIS)

    Polcaro, V.F.; Bazzano, A.; Ubertini, P.; La Padula, C.

    1984-01-01

    A general purpose method to deconvolve the energy spectra detected by means of the use of a hard X-ray telescope is described. The procedure does not assume any form of input spectrum and the observed energy loss spectrum is directly deconvolved into the incident photon spectrum, the form of which can be determined independently of physical interpretation of the data. Deconvolution of the hard X-ray spectrum of Her X-1, detected during the HXR 81M experiment, by the method independent method is presented. (orig.)

  19. The study on the X-ray correction method of long fracture displacement

    International Nuclear Information System (INIS)

    Jia Bin; Huang Ailing; Chen Fuzhong; Men Chunyan; Sui Chengzong; Cui Yiming; Yang Yundong

    2010-01-01

    Objective: To explore the image correction of fracture displacement by conventional X-ray photography (ortho tropic and lateral) and test by computed tomography (CT). Methods: The correction method of fracture displacement was designed according to geometry of X-ray photography. Selected one midhumeral fracture specimen which designed with lateral shift and angular displacement, and scanned from anteroposterior and position respectively, and also volume scanned using CT, the data obtained from volume scan were processed using multiplanar reconstruction (MPR) and shaded surface display (SSD). The displacement data relied on X-ray image, CT with MPR and SSD processing, actual design of specimens were compared respectively. Results: The direction and degree of displacement among correction data of X-ray images and the data from MPR and SSD, actual design of specimen were little difference, location difference <1.5 mm, degree difference <1.5 degree. Conclusion: It is really reliable for fracture displacement by conventional X-ray photography with coordinate correction, and it is helpful to obviously improve the diagnostic accuracy of the degree of fracture displacement. (authors)

  20. Instrument and method for X-ray diffraction, fluorescence, and crystal texture analysis without sample preparation

    Science.gov (United States)

    Gendreau, Keith (Inventor); Martins, Jose Vanderlei (Inventor); Arzoumanian, Zaven (Inventor)

    2010-01-01

    An X-ray diffraction and X-ray fluorescence instrument for analyzing samples having no sample preparation includes a X-ray source configured to output a collimated X-ray beam comprising a continuum spectrum of X-rays to a predetermined coordinate and a photon-counting X-ray imaging spectrometer disposed to receive X-rays output from an unprepared sample disposed at the predetermined coordinate upon exposure of the unprepared sample to the collimated X-ray beam. The X-ray source and the photon-counting X-ray imaging spectrometer are arranged in a reflection geometry relative to the predetermined coordinate.

  1. Soft X-ray production by photon scattering in pulsating binary neutron star sources

    International Nuclear Information System (INIS)

    Bussard, R.W.; Meszaros, P.; Alexander, S.

    1985-01-01

    A new mechanism is proposed as a source of soft (less than 1 keV) radiation in binary pulsating X-ray sources, in the form of photon scattering which leaves the electron in an excited Landau level. In a plasma with parameters typical of such sources, the low-energy X-ray emissivity of this mechanism far exceeds that of bremsstrahlung. This copious source of soft photons is quite adequate to provide the seed photons needed to explain the power-law hard X-ray spectrum by inverse Comptonization on the hot electrons at the base of the accretion column. 13 references

  2. Sister chromatid exchanges induced in CHO cells by X-rays or 5.5 MeV neutrons

    International Nuclear Information System (INIS)

    Bocian, E.; Rosiek, O.; Sablinski, J.; Ziemba-Zoltowska, B.

    1986-01-01

    The induction of sister chromatid exchanges (SCEs) by X-rays (1-9 Gy) and 5.5 MeV neutrons (0.5-4 Gy) was studied in CHO cells. A dose-dependent increase of the frequency of SCE was found for both radiations when cells with BrdUrd substituted DNA were irradiated. The similar doubling dose, approx. 4 Gy, was found for X-rays and neutrons. The increase of the SCE frequency was not clearly dependent on the dose when cells with BrdUrd unsubstituted DNA were irradiated. In this case a dose of 4 Gy enhanced the SCE frequency only by the factor of 1.3. (author)

  3. Characteristics of the neutron and X-ray tomography system at the SANRAD facility in South Africa

    International Nuclear Information System (INIS)

    Beer, F.C. de

    2005-01-01

    Through collaboration with the NEUTRA-facility at the Paul Scherrer Institute (PSI), Switzerland, a turnkey tomography system was designed specifically for the beam geometry at the South African Neutron Radiography (SANRAD) facility, located on the beam port floor of the SAFARI-1 nuclear research reactor and operated by Necsa. The new system is currently being extensively utilized in both 2D and 3D mode for various applications in general industry and institutional activities. The basic performance characteristics of its 3D tomography capability in a neutron and X-ray configuration are presented with the aid of several case studies. An X-ray source has also been commissioned to further diversify the capabilities of the facility

  4. Structural and dynamical study about denatured states of yeast phosphoglycerate kinase by neutrons scattering and X-rays

    International Nuclear Information System (INIS)

    Receveur, V.

    1997-01-01

    During a long time, the neutron scattering and X-rays techniques have not been used for the studies bearing on the folding of proteins. The compactness and the globularness of a protein are two structural characteristics describing the denatured states and the intermediate states of folding, and the neutrons and x-rays scattering are probably the two techniques the most appropriate to give this kind of information; they are sensible to the spatial extent and to the molecules compactness, and to their general shape. For these three or four last years, the works using these techniques are increasing, giving precious knowledge on the different steps of folding and on the interactions stabilizing the denatured or intermediate states. This thesis falls into this category. (N.C.)

  5. Application of the nuclear x-ray fluorescence method to prospecting for gold in-situ

    International Nuclear Information System (INIS)

    Zhang, Y.; Xie, T.; Zhou, S.; Ge, L.

    1989-01-01

    Arsenic and chalcophile elements are often associated with gold, and can be considered indicator elements when prospecting for gold deposits. The nuclear geophysics X-ray fluorescence method can be used to search for hidden gold deposits by measuring fluorescence intensities of the indicator elements in situ. The method can speed geologic investigation and reduce exploration cost. Three types of portable radioisotope X-ray fluorescence analyzers, designed and manufactured by Chengdu College of Geology and Chongqing Geological Instrument Factory, are briefly introduced. These analyzers are widely used in different stages of geologic investigation for gold in China. In the two case histories presented five anomalous zones of X-ray fluorescence intensity related to gold mineralization are located and one hidden gold deposit is discovered with gold content of 23 g/t

  6. Non-contact micro mass evaluation method using an X-ray microscope

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jiseok; Sun, Gwang Min; Baek, Ha Ni; Hoang, Sy Minh Tuan; Park, Sun Ae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-07-15

    For the mass inspection of attached foils such as printed electrodes, mass should be measured by a non-contact method with the capacity to measure a small mass of micrograms. In this study, the masses of 1 mg to 10 mg electrodes were evaluated using an X-ray microscope. The results were compared with the masses determined by using a digital scale with a 0.005 mg error. The average of the relative error between the mass measurements using the X-ray microscope and those using the digital scale was less than 2.51%. The results show that X-ray mass evaluation method can be used for mass measurement of micro objects by replacing a digital scale.

  7. Development of X-ray radiography examination technology by image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Min, Duck Kee; Koo, Dae Seo; Kim, Eun Ka [Korea Atomic Energy Research Institute, Taejon (Korea)

    1998-06-01

    Because the dimension of nuclear fuel rods was measured with rapidity and accuracy by X-ray radiography examination, the set-up of image processing system which was composed of 979 CCD-L camera, image processing card and fluorescent lighting was carried out, and the image processing system enabled image processing to perform. The examination technology of X-ray radiography, which enabled dimension measurement of nuclear fuel rods to perform, was developed by image processing method. The result of dimension measurement of standard fuel rod by image processing method was 2% reduction in relative measuring error than that of X-ray radiography film, while the former was better by 100 {approx} 200 {mu}m in measuring accuracy than the latter. (author). 9 refs., 22 figs., 3 tabs.

  8. High resolution x-ray CMT: Reconstruction methods

    Energy Technology Data Exchange (ETDEWEB)

    Brown, J.K.

    1997-02-01

    This paper qualitatively discusses the primary characteristics of methods for reconstructing tomographic images from a set of projections. These reconstruction methods can be categorized as either {open_quotes}analytic{close_quotes} or {open_quotes}iterative{close_quotes} techniques. Analytic algorithms are derived from the formal inversion of equations describing the imaging process, while iterative algorithms incorporate a model of the imaging process and provide a mechanism to iteratively improve image estimates. Analytic reconstruction algorithms are typically computationally more efficient than iterative methods; however, analytic algorithms are available for a relatively limited set of imaging geometries and situations. Thus, the framework of iterative reconstruction methods is better suited for high accuracy, tomographic reconstruction codes.

  9. Method of evaluation of structural (screen) and quantum graininess of X-ray pictures

    Energy Technology Data Exchange (ETDEWEB)

    Gurvich, A M; Shamanov, A A; Erofeeva, N D [Nauchno-Issledovatel' skij Inst. Rentgenologii i Radiologii, Moscow (USSR)

    1979-03-01

    Proposed is a method for quantitative determination of graininess of X-ray pictures (gamma-ray images), the graininess being conditioned by the structure of amplifying screens and quantum fluctuations. The method is based on the determination of threshold brightness at which the picture graininess becomes obvious. It is shown that at low effective quantum energy (Esub(eff.) <= 50 keV) the graininess observed is for the most part structural (screen). Its growth is connected with quantum fluctuations when increasing Esub(eff.) up to 150 keV and using screens with high output values of X-ray luminescence and the coefficient of spectral accordance to the film.

  10. Ordering phenomena in FeCo-films and Fe/Cr-multilayers: an X-ray and neutron scattering study

    Energy Technology Data Exchange (ETDEWEB)

    Nickel, B.

    2001-07-01

    The following topics are covered: critical phenomena in thin films, critical adsorption, finite size scaling, FeCo Ising model, kinematical scattering theory for thin films, FeCo thin films, growth and characterisation of single crystal FeCo thin films, X-ray study of ordering in FeCo films, antiferromagnetic coupling in Fe/Cr multilayers, neutron scattering on Fe/Cr multilayers (WL)

  11. Research on pinches driven by Speed-2 generator: Hard X-ray and neutron emission in plasma focus configuration

    Energy Technology Data Exchange (ETDEWEB)

    Soto, L.; Moreno, J.; Silva, P.; Sylvester, G.; Zambra, M.; Pavez, C. [Comision Chilena de Energia Nuclear, Santiago (Chile); Pavez, C. [Universidad de Concepcion (Chile); Raspa, V. [Buenos Aires Univ., PLADEMA, CONICET and INFIP (Argentina); Castillo, F. [Insitituto de Ciencias Nucleares, UNAM (Mexico); Kies, W. [Heinrich-Heine-Univ., Dusseldorf (Germany)

    2004-07-01

    Speed-2 is a generator based on Marx technology and was designed in the University of Dusseldorf. Speed-2 consists on 40 +/- Marx modules connected in parallel (4.1 {mu}F equivalent Marx generator capacity, 300 kV, 4 MA in short circuit, 187 kJ, 400 ns rise time, dI/dt {approx} 10{sup 13} A/s). Currently Speed-2 is operating at CCHEN (Chilean nuclear energy commission), being the most powerful and energetic device for dense transient plasma in the Southern Hemisphere. Most of the previous works developed in Speed-2 at Dusseldorf were done in a plasma focus configuration for soft X-ray emission and the neutron emission from Speed-2 was not completely studied. The research program at CCHEN considers experiments in different pinch configurations (plasma focus, gas puffed plasma focus, gas embedded Z-pinch, wire arrays) at current of hundred of kilo- to mega-amperes, using the Speed-2 generator. The Chilean operation has begun implementing and developing diagnostics in a conventional plasma focus configuration operating in deuterium in order to characterize the neutron emission and the hard X-ray production. Silver activation counters, plastics CR39 and scintillator-photomultiplier detectors are used to characterize the neutron emission. Images of metallic plates with different thickness are obtained on commercial radiographic film, Agfa Curix ST-G2, in order to characterize an effective energy of the hard X-ray outside of the discharge. (authors)

  12. Research of x-ray automatic image mosaic method

    Science.gov (United States)

    Liu, Bin; Chen, Shunan; Guo, Lianpeng; Xu, Wanpeng

    2013-10-01

    Image mosaic has widely applications value in the fields of medical image analysis, and it is a technology that carries on the spatial matching to a series of image which are overlapped with each other, and finally builds a seamless and high quality image which has high resolution and big eyeshot. In this paper, the method of grayscale cutting pseudo-color enhancement was firstly used to complete the mapping transformation from gray to the pseudo-color, and to extract SIFT features from the images. And then by making use of a similar measure of NCC (normalized cross correlation - Normalized cross-correlation), the method of RANSAC (Random Sample Consensus) was used to exclude the pseudofeature points right in order to complete the exact match of feature points. Finally, seamless mosaic and color fusion were completed by using wavelet multi-decomposition. The experiment shows that the method we used can effectively improve the precision and automation of the medical image mosaic, and provide an effective technical approach for automatic medical image mosaic.

  13. X-ray astronomy

    International Nuclear Information System (INIS)

    Culhane, J.L.; Sanford, P.W.

    1981-01-01

    X-ray astronomy has been established as a powerful means of observing matter in its most extreme form. The energy liberated by sources discovered in our Galaxy has confirmed that collapsed stars of great density, and with intense gravitational fields, can be studied by making observations in the X-ray part of the electromagnetic spectrum. The astronomical objects which emit detectable X-rays include our own Sun and extend to quasars at the edge of the Universe. This book describes the history, techniques and results obtained in the first twenty-five years of exploration. Space rockets and satellites are essential for carrying the instruments above the Earth's atmosphere where it becomes possible to view the X-rays from stars and nebulae. The subject is covered in chapters, entitled: the birth of X-ray astronomy; the nature of X-radiation; X-rays from the Sun; solar-flare X-rays; X-rays from beyond the solar system; supernovae and their remnants; X-rays from binary stars; white dwarfs and neutron stars; black holes; X-rays from galaxies and quasars; clusters of galaxies; the observatories of the future. (author)

  14. General Relativistic Radiation MHD Simulations of Supercritical Accretion onto a Magnetized Neutron Star: Modeling of Ultraluminous X-Ray Pulsars

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Hiroyuki R. [Center for Computational Astrophysics, National Astronomical Observatory of Japan, National Institutes of Natural Sciences, Mitaka, Tokyo 181-8588 (Japan); Ohsuga, Ken, E-mail: takahashi@cfca.jp, E-mail: ken.ohsuga@nao.ac.jp [Division of Theoretical Astronomy, National Astronomical Observatory of Japan, National Institutes of Natural Sciences, Mitaka, Tokyo 181-8588 (Japan)

    2017-08-10

    By performing 2.5-dimensional general relativistic radiation magnetohydrodynamic simulations, we demonstrate supercritical accretion onto a non-rotating, magnetized neutron star, where the magnetic field strength of dipole fields is 10{sup 10} G on the star surface. We found the supercritical accretion flow consists of two parts: the accretion columns and the truncated accretion disk. The supercritical accretion disk, which appears far from the neutron star, is truncated at around ≃3 R {sub *} ( R {sub *} = 10{sup 6} cm is the neutron star radius), where the magnetic pressure via the dipole magnetic fields balances with the radiation pressure of the disks. The angular momentum of the disk around the truncation radius is effectively transported inward through magnetic torque by dipole fields, inducing the spin up of a neutron star. The evaluated spin-up rate, ∼−10{sup −11} s s{sup −1}, is consistent with the recent observations of the ultraluminous X-ray pulsars. Within the truncation radius, the gas falls onto a neutron star along the dipole fields, which results in a formation of accretion columns onto the northern and southern hemispheres. The net accretion rate and the luminosity of the column are ≃66 L {sub Edd}/ c {sup 2} and ≲10 L {sub Edd}, where L {sub Edd} is the Eddington luminosity and c is the light speed. Our simulations support a hypothesis whereby the ultraluminous X-ray pulsars are powered by the supercritical accretion onto the magnetized neutron stars.

  15. Computerized method for X-ray angular distribution simulation in radiological systems

    International Nuclear Information System (INIS)

    Marques, Marcio A.; Oliveira, Henrique J.Q. de; Frere, Annie F.; Schiabel, Homero; Marques, Paulo M.A.

    1996-01-01

    A method to simulate the changes in X-ray angular distribution (the Heel effect) for radiologic imaging systems is presented. This simulation method is described as to predict images for any exposure technique considering that the distribution is the cause of the intensity variation along the radiation field

  16. Precision evaluation of pressed pastille preparation different methods for X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Lima, Raquel Franco de Souza; Melo Junior, Germano; Sa, Jaziel Martins

    1997-01-01

    This work relates the comparison between the results obtained with the two different methods of preparing pressed pastilles from the crushed sample. In this study, the reproductivity is evaluated, aiming to define the method that furnishes a better analytic precision. These analyses were realized with a X-ray fluorescence spectrometer at the Geology Department of the Federal University of Rio Grande do Norte

  17. Method for x-ray determination of three axial stresses of general orientation

    Energy Technology Data Exchange (ETDEWEB)

    Doelle, H; Hauk, V [Technische Hochschule Aachen (Germany, F.R.). Inst. fuer Werkstoffkunde; Juehe, H H; Krause, H [Technische Hochschule Aachen (Germany, F.R.). Lehrgebiet Abnutzung der Werkstoffe

    1976-11-01

    The authors describe a method of detecting three-dimensional self-stress/self-strain systems by means of X-ray measurements of the distances between the lattice planes in three directions of the sample surface. The method is illustrated by a study of a sample from a type of an electric railcar which had been deformed mainly by tangential forces.

  18. Quantitative phase analysis of uranium carbide from x-ray diffraction data using the Rietveld method

    International Nuclear Information System (INIS)

    Singh Mudher, K.D.; Krishnan, K.

    2003-01-01

    Quantitative phase analysis of a uranium carbide sample was carried out from the x-ray diffraction data by Rietveld profile fitting method. The method does not require the addition of any reference material. The percentage of UC, UC 2 and UO 2 phases in the sample were determined. (author)

  19. The method of quantitative X-ray microanalysis of fine inclusions in copper

    International Nuclear Information System (INIS)

    Morawiec, H.; Kubica, L.; Piszczek, J.

    1978-01-01

    The method of correction for the matrix effect in quantitative x-ray microanalysis was presented. The application of the method was discussed on the example of quantitative analysis of fine inclusions of Cu 2 S and Cu 2 O in copper. (author)

  20. Fast, versatile x-ray fluorescence method for measuring tin in impregnated wood

    DEFF Research Database (Denmark)

    Drabæk, I.; Christensen, Leif Højslet

    1985-01-01

    The present paper describes an energy-dispersive x-ray fluorescence method for measuring tin in bis(tri-n-butyl)tin-oxide impregnated wood. The proposed method is of the backscatter/fundamental parameter type. Its versatility, precision, and accuracy is demonstrated by analyses of eleven samples...

  1. Inspection method of optical fiber preforms by x-ray absorption measurements

    International Nuclear Information System (INIS)

    Takahashi, H.; Nakamura, K.; Shibuya, S.; Kuroha, T.

    1980-01-01

    A method for measuring the refractive index distribution of optical fiber preforms has been developed by application of the theory of X-ray radiography. The composition of quartz optical fiber materials is, in most cases, limited to the group of five elements - Ge, P, Si, O and B. Of them, Ge is an essential element to determine the structure of refractive index of an optical fiber and the distribution of its density can be regarded approximately as the distribution of refractive index. On the other hand, the coefficient of low-energy X-ray absorption by the elements depends markedly on their atomic numbers, and Ge has a far larger absorption coefficient than the other four elements. Therefore, analysis of the intensity of X-ray absorbed by optical fiber preforms makes it possible to determine the distribution of Ge density and consequently the distribution of refractive index. (author)

  2. Determination of Ti, Cr, Cu and Ta in niobium oxide by X-ray fluorescence method

    International Nuclear Information System (INIS)

    Dixit, R.M.; Deshpande, S.S.

    1986-01-01

    An x-ray fluorescence method for the determination of Ti, Cr, Cu and Ta in niobium oxide has been developed. Samples/standards in powder form are mixed with boric acid in the proportion of 1:1 (400 mg. each). Double layer pellets are prepared by pressing this mixture over a primary boric acid pellet. Philips PW-1220, a semiautomatic x-ray spectrometer with tungsten target x-ray tube for excitation and LiF (200) crystal for dispersion have been used. The determination range is from 0.005 to 0.1per cent for Ti and Cr, 0.01 to 0.1per cent for Cu and 0.05 to 1per cent for Ta. (author)

  3. Note: Loading method of molecular fluorine using x-ray induced chemistry

    International Nuclear Information System (INIS)

    Pravica, Michael; Sneed, Daniel; White, Melanie; Wang, Yonggang

    2014-01-01

    We have successfully loaded molecular fluorine into a diamond anvil cell at high pressure using the synchrotron x-ray induced decomposition of perfluorohexane (C 6 F 14 ). “White” x-ray radiation from the Advanced Photon Source was used to initiate the chemical decomposition of C 6 F 14 , which resulted in the in situ production of F 2 as verified via Raman spectroscopy. Due to the toxic nature of fluorine, this method will offer significant advantages in the ability to easily load a relatively nontoxic and inert substance into a chamber (such as a diamond anvil cell) that, when sealed with other reactants and irradiate with hard x-rays (>7 keV), releases highly reactive and toxic fluorine into the sample/reaction chamber to enable novel chemical synthesis under isolated and/or extreme conditions

  4. Long wave-length x-ray diffraction crystal and method of manufacturing same

    International Nuclear Information System (INIS)

    Zingaro, W.P.; Sicignano, A.

    1980-01-01

    An x-ray diffraction crystal of the Langemuir-Blodgett type capable of detecting radiation having a wavelength greater than 50 Arystroms and a method of making such a crystal are described. The crystal consists of a pair of alternate monolayers, one a heavy metal soap, and one a light metal soap. Selecting cation pairs with a significant difference in atomic number and dispersing power, such as Pb and Be, Mg, or Ca, increases the effective interplanar distance since the Pb planes cause the predominant x-ray diffraction. (LL)

  5. Note: A novel method for in situ loading of gases via x-ray induced chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Pravica, Michael; Bai, Ligang; Park, Changyong; Liu, Yu; Galley, Martin; Robinson, John; Bhattacharya, Neelanjan (UNLV); (CIW)

    2011-12-14

    We have developed and demonstrated a novel method to load oxygen in a sealed diamond anvil cell via the x-ray induced decomposition of potassium chlorate. By irradiating a pressurized sample of an oxidizer (KClO{sub 3}) with either monochromatic or white beam x-rays from the Advanced Photon Source at ambient temperature and variable pressure, we succeeded in creating a localized region of molecular oxygen surrounded by unreacted sample which was confirmed via Raman spectroscopy. We anticipate that this technique will be useful in loading even more challenging, difficult-to-load gases such as hydrogen and also to load multiple gases.

  6. Note: A novel method for in situ loading of gases via x-ray induced chemistry

    Science.gov (United States)

    Pravica, Michael; Bai, Ligang; Park, Changyong; Liu, Yu; Galley, Martin; Robinson, John; Bhattacharya, Neelanjan

    2011-10-01

    We have developed and demonstrated a novel method to load oxygen in a sealed diamond anvil cell via the x-ray induced decomposition of potassium chlorate. By irradiating a pressurized sample of an oxidizer (KClO3) with either monochromatic or white beam x-rays from the Advanced Photon Source at ambient temperature and variable pressure, we succeeded in creating a localized region of molecular oxygen surrounded by unreacted sample which was confirmed via Raman spectroscopy. We anticipate that this technique will be useful in loading even more challenging, difficult-to-load gases such as hydrogen and also to load multiple gases.

  7. Advanced x-ray stress analysis method for a single crystal using different diffraction plane families

    International Nuclear Information System (INIS)

    Imafuku, Muneyuki; Suzuki, Hiroshi; Sueyoshi, Kazuyuki; Akita, Koichi; Ohya, Shin-ichi

    2008-01-01

    Generalized formula of the x-ray stress analysis for a single crystal with unknown stress-free lattice parameter was proposed. This method enables us to evaluate the plane stress states with any combination of diffraction planes. We can choose and combine the appropriate x-ray sources and diffraction plane families, depending on the sample orientation and the apparatus, whenever diffraction condition is satisfied. The analysis of plane stress distributions in an iron single crystal was demonstrated combining with the diffraction data for Fe{211} and Fe{310} plane families

  8. Detection methods of pulsed X-rays for transmission tomography with a linear accelerator

    International Nuclear Information System (INIS)

    Glasser, F.

    1988-07-01

    Appropriate detection methods are studied for the development of a high energy tomograph using a linear accelerator for nondestructive testing of bulky objects. The aim is the selection of detectors adapted to a pulsed X-ray source and with a good behavior under X-ray radiations of several MeV. Performance of semiconductors (HgI 2 , Cl doped CdTe, GaAs, Bi 12 Ge0 20 ) and a scintillator (Bi 4 Ge 3 0 12 ) are examined. A prototype tomograph gave images that show the validity of detectors for analysis of medium size equipment such as a concrete drum of 60 cm in diameter [fr

  9. Preliminary study of determination of UO2 grain size using X-ray diffraction method

    International Nuclear Information System (INIS)

    Mulyana, T.; Sambodo, G. D.; Juanda, D.; Fatchatul, B.

    1998-01-01

    The determination of UO 2 grain size has accomplished using x-ray diffraction method. The UO 2 powder is obtained from sol-gel process. A copper target as radiation source in the x-ray diffractometer was used in this experiment with CμKα characteristic wavelength 1.54433 Angstrom. The result indicate that the UO 2 mean grain size on presintered (temperature 800 o C) has the value 456.8500 Angstrom and the UO 2 mean grain size on sintered (temperature 1700 o C) has value 651.4934 Angstrom

  10. Radiation exposure in X-ray angiography and comparisons between digital and conventional methods of imaging

    International Nuclear Information System (INIS)

    Schaberg, J.

    1987-01-01

    The more recent developments and techniques in the field of angiography are examined for associated radiation exposure risks for patients and investigators and then compared to the conventional methods of angiography. It could be shown that digital subtraction angiography is generally associated with a lesser risk of somatic exposure of the patient, provided that the equipment used offers an adjustable useful-beam range and focus. The fact that above-table X-ray tubes are now generally replaced with X-ray systems installed under the examination table permits the relatively high doses, to which investigators are exposed during angiography, to be reduced by a factor of 3. (DG) [de

  11. X-ray photon-in/photon-out methods for chemical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Marcus, Matthew A.

    2010-03-24

    Most interesting materials in nature are heterogeneous, so it is useful to have analytical techniques with spatial resolution sufficient to resolve these heterogeneities.This article presents the basics of X-ray photon-in/photon-out chemical imaging. This family of methods allows one to derive images reflectingthe chemical state of a given element in a complex sample, at micron or deep sub-micron scale. X-ray chemical imaging is relatively non-destructiveand element-selective, and requires minimal sample preparation. The article presents the basic concepts and some considerations of data takingand data analysis, along with some examples.

  12. Cation distribution in a Fe-bearing K-feldspar from Itrongay,Madagascar. A combined neutron- and X-ray single crystal diffractionstudy

    Energy Technology Data Exchange (ETDEWEB)

    Ackermann, Sonia; Kunz, Martin; Armbruster, Thomas; Schefer,Jurg; Hanni, Henry

    2005-05-02

    We determined the cation distribution and ordering of Si, Al and Fe on the tetrahedral sites of a monoclinic low-sanidine from Itrongay, Madagascar, by combined neutron- and X-ray single-crystal diffraction. The cation distribution was determined by means of a simultaneous refinement using neutron- and X-ray data, as well as by combining scattering densities obtained from separate refinements with chemical data from a microprobe experiment. The two methods give the same results and show that Fe is fully ordered on T1, whereas Al shows a high degree of disorder. Based on this and previously published temperature-dependent X-ray data, we conclude that it is preferential ordering of Fe on T1 even at high temperature, rather than a high diffusion kinetics of Fe, which causes this asymmetry in ordering behavior between Al and Fe. The preferential ordering of Fe3+ relative to Al3+ in T1 is consistent with its 25 percent larger ionic radius.

  13. Neutron and soft X-ray emission from wire array Z-pinch imploding onto deuterated fiber

    International Nuclear Information System (INIS)

    Klir, D.; Kravarik, J.; Kubes, P.

    2005-01-01

    The implosion of a wire array Z-pinch onto a deuterated fiber was studied. The peak power of soft X-rays exceeded 200 GW and the total emitted energy was 2-8 kJ. The radiation was close to the radiation of the blackbody with the temperature of 40 eV. The neutron yield from the D-D reaction reached 2x10 8 per shot. The mean energy of neutrons determined in the axial direction was shifted from 2.45 MeV towards higher energies [ru

  14. Statistical analysis of x-ray stress measurement by centroid method

    International Nuclear Information System (INIS)

    Kurita, Masanori; Amano, Jun; Sakamoto, Isao

    1982-01-01

    The X-ray technique allows a nondestructive and rapid measurement of residual stresses in metallic materials. The centroid method has an advantage over other X-ray methods in that it can determine the angular position of a diffraction line, from which the stress is calculated, even with an asymmetrical line profile. An equation for the standard deviation of the angular position of a diffraction line, σsub(p), caused by statistical fluctuation was derived, which is a fundamental source of scatter in X-ray stress measurements. This equation shows that an increase of X-ray counts by a factor of k results in a decrease of σsub(p) by a factor of 1/√k. It also shows that σsub(p) increases rapidly as the angular range used in calculating the centroid increases. It is therefore important to calculate the centroid using the narrow angular range between the two ends of the diffraction line where it starts to deviate from the straight background line. By using quenched structural steels JIS S35C and S45C, the residual stresses and their standard deviations were calculated by the centroid, parabola, Gaussian curve, and half-width methods, and the results were compared. The centroid of a diffraction line was affected greatly by the background line used. The standard deviation of the stress measured by the centroid method was found to be the largest among the four methods. (author)

  15. Rating of the X-ray method of measurement of stresses in steels

    International Nuclear Information System (INIS)

    Skrzypinski, A.

    1977-01-01

    The possibilities of utilization of some dependencies occuring in the X-ray technique of measurement of natural stresses for determination of distances of a between - plane lattice without natural stresses (d 0 ) are discussed. The proposed methodics of determination of d 0 is illustrated with the investigations which were carried-out on bearing steel LH15. (author)

  16. The X-ray fluorescent method for determination of total sulphur in bituminous coals

    International Nuclear Information System (INIS)

    Widowska-Kusmierska, J.; Siess, K.

    1979-01-01

    The X-ray fluorescent technique for the determination of total sulphur covering concentrations from 0,1 to 10% has been applied for bituminous coals showing a great variability in qualitative and quantitative composition of mineral matter (ash). The described method is a quick one giving results during one hour. The obtained good accuracy of determinations gives prospects for wide industrial application. (author)

  17. A greedy method for reconstructing polycrystals from three-dimensional X-ray diffraction data

    DEFF Research Database (Denmark)

    Kulshreshth, Arun Kumar; Alpers, Andreas; Herman, Gabor T.

    2009-01-01

    An iterative search method is proposed for obtaining orientation maps inside polycrystals from three-dimensional X-ray diffraction (3DXRD) data. In each step, detector pixel intensities are calculated by a forward model based on the current estimate of the orientation map. The pixel at which...

  18. Matching methods evaluation framework for stereoscopic breast x-ray images.

    Science.gov (United States)

    Rousson, Johanna; Naudin, Mathieu; Marchessoux, Cédric

    2016-01-01

    Three-dimensional (3-D) imaging has been intensively studied in the past few decades. Depth information is an important added value of 3-D systems over two-dimensional systems. Special focuses were devoted to the development of stereo matching methods for the generation of disparity maps (i.e., depth information within a 3-D scene). Dedicated frameworks were designed to evaluate and rank the performance of different stereo matching methods but never considering x-ray medical images. Yet, 3-D x-ray acquisition systems and 3-D medical displays have already been introduced into the diagnostic market. To access the depth information within x-ray stereoscopic images, computing accurate disparity maps is essential. We aimed at developing a framework dedicated to x-ray stereoscopic breast images used to evaluate and rank several stereo matching methods. A multiresolution pyramid optimization approach was integrated to the framework to increase the accuracy and the efficiency of the stereo matching techniques. Finally, a metric was designed to score the results of the stereo matching compared with the ground truth. Eight methods were evaluated and four of them [locally scaled sum of absolute differences (LSAD), zero mean sum of absolute differences, zero mean sum of squared differences, and locally scaled mean sum of squared differences] appeared to perform equally good with an average error score of 0.04 (0 is the perfect matching). LSAD was selected for generating the disparity maps.

  19. Cone Beam X-ray Luminescence Computed Tomography Based on Bayesian Method.

    Science.gov (United States)

    Zhang, Guanglei; Liu, Fei; Liu, Jie; Luo, Jianwen; Xie, Yaoqin; Bai, Jing; Xing, Lei

    2017-01-01

    X-ray luminescence computed tomography (XLCT), which aims to achieve molecular and functional imaging by X-rays, has recently been proposed as a new imaging modality. Combining the principles of X-ray excitation of luminescence-based probes and optical signal detection, XLCT naturally fuses functional and anatomical images and provides complementary information for a wide range of applications in biomedical research. In order to improve the data acquisition efficiency of previously developed narrow-beam XLCT, a cone beam XLCT (CB-XLCT) mode is adopted here to take advantage of the useful geometric features of cone beam excitation. Practically, a major hurdle in using cone beam X-ray for XLCT is that the inverse problem here is seriously ill-conditioned, hindering us to achieve good image quality. In this paper, we propose a novel Bayesian method to tackle the bottleneck in CB-XLCT reconstruction. The method utilizes a local regularization strategy based on Gaussian Markov random field to mitigate the ill-conditioness of CB-XLCT. An alternating optimization scheme is then used to automatically calculate all the unknown hyperparameters while an iterative coordinate descent algorithm is adopted to reconstruct the image with a voxel-based closed-form solution. Results of numerical simulations and mouse experiments show that the self-adaptive Bayesian method significantly improves the CB-XLCT image quality as compared with conventional methods.

  20. X-ray diagnostics for TFTR

    International Nuclear Information System (INIS)

    von Goeler, S.; Hill, K.W.; Bitter, M.

    1982-12-01

    A short description of the x-ray diagnostic preparation for the TFTR tokamak is given. The x-ray equipment consists of the limiter x-ray monitoring system, the soft x-ray pulse-height-analysis-system, the soft x-ray imaging system and the x-ray crystal spectrometer. Particular attention is given to the radiation protection of the x-ray systems from the neutron environment

  1. A method of simultaneous no-screen X-ray film taking with direct twofold magnification of hands and feet

    International Nuclear Information System (INIS)

    Zajgner, J.; Szymanska-Prach, H.

    1978-01-01

    The authors propose an original method of X-ray examination of hands and feet which makes possible simultaneous radiography without screen and direct twofold magnified film taking. The method is not connected with the necessity of exposing the patient to an additional dose of X-rays. It has been tried in 20 patients with suspected rheumatoid arthritis. It requires an X-ray tube with 0.3 x 0.3 mm microfocus. (author)

  2. Disorder and transport properties of In3SbTe2 - an X-ray, neutron and electron diffraction study

    International Nuclear Information System (INIS)

    Schroeder, Thorsten; Rosenthal, Tobias; Grott, Sebastian; Stiewe, Christian; Boor, Johannes de; Oeckler, Oliver

    2013-01-01

    Quenched metastable In 3 SbTe 2 was investigated by X-ray and neutron powder diffraction as well as by single-crystal X-ray diffraction. The average structure corresponds to the rocksalt type, the anion position being occupied by antimony and tellurium. Neutron data indicate no antisite disorder of indium and antimony. The compound is a high-temperature phase that can be quenched to yield a metastable compound at ambient temperature which, upon heating, decomposes at ca. 320 C into InSb and InTe. Diffuse scattering in reconstructed X-ray and selected area electron diffraction patterns indicates local distortions of the crystal structure due to static atom displacement along <100> from the average positions, caused by the different size of the anions, but no superstructure. The electrical conductivity of In 3 SbTe 2 is 3.2 x 10 4 S.cm -1 at 25 C, the temperature characteristics correspond to metallic behavior. Consequently, the thermal conductivity is also rather high. The decomposition into InSb and InTe reduces the electrical conductivity by a factor of 3 in heterogeneous microstructures. (Copyright copyright 2013 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  3. ORBITAL VARIATION OF THE X-RAY EMISSION FROM THE DOUBLE NEUTRON STAR BINARY J1537+1155

    International Nuclear Information System (INIS)

    Durant, Martin; Kargaltsev, Oleg; Volkov, Igor; Pavlov, George G.

    2011-01-01

    We observed the double neutron star binary (DNSB) containing PSR J1537+1155 (also known as B1534+12) with the Chandra X-Ray Observatory. This is one of the two DNSBs detected in X-rays and the only one where a hint of variability with orbital phase was found (in the previous Chandra observation). Our follow-up observation supports the earlier result: the distribution of photon arrival times with orbital phase again shows a deficit around apastron. The significance of the deficit in the combined data set exceeds 99%. Such an orbital light curve suggests that the X-ray emission is seen only when neutron star (NS) B passes through the equatorial pulsar wind of NS A. We describe statistical tests that we used to determine the significance of the deficit, and conclusions that can be drawn from its existence, such as interaction of the pulsar wind with the NS companion. We also provide better constrained spectral model parameters obtained from the joint spectral fits to the data from both observations. A power law successfully fits the data, with best-fit photon index Γ = 3.1 ± 0.4 and unabsorbed flux f = (3.2 ± 0.8) × 10 –15 erg s –1 cm –2 (0.3-8 keV range).

  4. X-ray and fast neutron-induced mutations in Arabidopsis thaliana, and the effect of dithiothreitol upon the mutant spectrum

    International Nuclear Information System (INIS)

    Dellaert, L.M.W.

    1980-01-01

    The author discusses the genetic effects of X-ray and fast neutron seed-irradiation of Arabidopsis thaliana (L.) Heynh., and the influence of a pre-irradiation treatment with the radio-protector dithiothreitol (DTT). (Auth.)

  5. A comparison between the Structural Results obtained by X-ray Single Crystal Data and by Neutron Powder Data for BaVs/sb3/

    International Nuclear Information System (INIS)

    Marezio, M.

    1986-01-01

    The structure of BaVs/sb3/, as refined from X-ray single-crystal data to an R factor of 0.011, is compared to the structure of the same compound obtained from neutron powder data (Rsb(ro) = 6.82, Rsb(psilon) = 4.09). As expected, the X-ray standard deviations of the positional and thermal parameters are smaller than the corresponding neutron standard deviations. However, the dynamical disorder deduced from the anomalously large thermal vibrations of the vanadium atoms obtained from the X-ray data is also evidenced by the neutron refinement. On the other hand, the neutron standard deviations of the lattice parameters are smaller than the X-ray counterparts

  6. A convenient method for X-ray analysis in TEM that measures mass thickness and composition

    Science.gov (United States)

    Statham, P.; Sagar, J.; Holland, J.; Pinard, P.; Lozano-Perez, S.

    2018-01-01

    We consider a new approach for quantitative analysis in transmission electron microscopy (TEM) that offers the same convenience as single-standard quantitative analysis in scanning electron microscopy (SEM). Instead of a bulk standard, a thin film with known mass thickness is used as a reference. The procedure involves recording an X-ray spectrum from the reference film for each session of acquisitions on real specimens. There is no need to measure the beam current; the current only needs to be stable for the duration of the session. A new reference standard with a large (1 mm x 1 mm) area of uniform thickness of 100 nm silicon nitride is used to reveal regions of X-ray detector occlusion that would give misleading results for any X-ray method that measures thickness. Unlike previous methods, the new X-ray method does not require an accurate beam current monitor but delivers equivalent accuracy in mass thickness measurement. Quantitative compositional results are also automatically corrected for specimen self-absorption. The new method is tested using a wedge specimen of Inconel 600 that is used to calibrate the high angle angular dark field (HAADF) signal to provide a thickness reference and results are compared with electron energy-loss spectrometry (EELS) measurements. For the new X-ray method, element composition results are consistent with the expected composition for the alloy and the mass thickness measurement is shown to provide an accurate alternative to EELS for thickness determination in TEM without the uncertainty associated with mean free path estimates.

  7. Cell inactivation and chromosomal aberrations induced by X-rays and fast neutrons in cells of the Chinese hamster. 1

    International Nuclear Information System (INIS)

    Tolkendorf, E.

    1979-01-01

    Asynchronously grown cultures of Chinese hamster cells V79-4 were irradiated in suspension with 180 kV X-rays and fast neutrons (average energy of 6.2 MeV). The damage was assessed by measuring cell survival and frequencies of chromosome aberrations in the first post-irradiation metaphases. The experimental data for survival and chromosome aberrations were fitted by computer programmes. From the fitted curves the relative biological effectiveness (RBE) of fast neutrons was calculated. The RBE shows a similar dose dependence for killed and aberrant cells. The RBE decreases with increasing dose and amounts to approximately 5 for both effects for small neutron doses. The highest RBE is found for asymmetrical chromosomal exchanges and is dependent on the neutron dose, too. However, for isochromatid deletions the RBE is dose independent with a value of 3.6. (author)

  8. X-ray imaging with monochromatic synchrotron radiation. Fluorescent and phase-contrast method

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, Tohoru; Itai, Yuji [Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine

    2002-05-01

    To obtain the high sensitive x-ray images of biomedical object, new x-ray imaging techniques using fluorescent x-ray and phase-contrast x-ray are being developed in Japan. Fluorescent x-ray CT can detect very small amounts of specific elements in the order of ppm at one pixel, whereas phase-contrast x-ray imaging with interferometer can detect minute differences of biological object. Here, our recent experimental results are presented. (author)

  9. Radiation dosimetry by neutron or X ray fluorescence activation of residual silver in ionographic emulsions

    International Nuclear Information System (INIS)

    Heilmann, C.

    1987-01-01

    A global measuring technique which is sensitive enough to detect small silver contents in films for dosimetry applications is presented. The applications studied are neutron dosimetry by measuring residual silver due to recoil protons in developed emulsions and high dose dosimetry by the detection of photolytic silver in fixed emulsions. An individual fast neutron dosimeter which can be used in radiation protection was developed, along with an automatic data analysis and readout system. Application of this technique to the measurement of high radiation doses (100 to 1 million Gy) via the measurement of photolytic silver in fixed, but undeveloped, emulsions confirms the usefulness of the method [fr

  10. The magnetic order of GdMn₂Ge₂ studied by neutron diffraction and x-ray resonant magnetic scattering.

    Science.gov (United States)

    Granovsky, S A; Kreyssig, A; Doerr, M; Ritter, C; Dudzik, E; Feyerherm, R; Canfield, P C; Loewenhaupt, M

    2010-06-09

    The magnetic structure of GdMn₂Ge₂ (tetragonal I4/mmm) has been studied by hot neutron powder diffraction and x-ray resonant magnetic scattering techniques. These measurements, along with the results of bulk experiments, confirm the collinear ferrimagnetic structure with moment direction parallel to the c-axis below T(C) = 96 K and the collinear antiferromagnetic phase in the temperature region T(C) < T < T(N) = 365 K. In the antiferromagnetic phase, x-ray resonant magnetic scattering has been detected at Mn K and Gd L₂ absorption edges. The Gd contribution is a result of an induced Gd 5d electron polarization caused by the antiferromagnetic order of Mn-moments.

  11. DMSO-induced dehydration of DPPC membranes studied by x-ray diffraction, small angle neutron scattering and calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Kiselev, M A; Kiselev, A M [Frank Laboratory of Neutron Physics, Joint Institute for Nuclear Research, Dubna (Russian Federation); Lesieur, P [LURE, Universite Paris-Sud, Bat. 209-D, F91405 Orsay cedex, (France); Grabielle-Madelmond, C; Ollivon, M [Physico-Chimie des systemes polyphases, URA 1218 du CNRS, Faculte de Pharmacie, tour B, F-92296, Chatenay Malabry (France)

    1998-12-01

    The properties of dimethyl sulfoxide (DMSO), a cryoprotector well known for its biological and therapeutic applications, were investigated on lipid membranes by x-ray diffraction, differential scanning calorimetry (DSC) and small angle neutron scattering (SANS). The DSC study of water freezing and melting of ice was performed in the ternary system which consists of 1,2-dipalmitoyl-sn-glycero-3-phosphatidylcholine (DPPC)/DMSO/water system. The influence of DMSO on the DPPC membrane structure was established in the excess of solvent in the region of DMSO mole fraction from 0.0 to 1.0. The methods applied demonstrated the differences in the membrane structure in three sub-regions of DMSO mole fraction (X{sub DMSO}) from 0.0 to 0.3 for the first, from 0.3 to 0.9 for the second, and from 0.9 to 1.0 for the third sub-region. The results for 0.0 {<=} X{sub DMSO} {<=} 0.3 can be explained in the framework of DMSO-induced dehydration of intermembrane space 11 refs., 7 figs. Submitted to the Conference `ISSRNS`98`, 15-20 Jun 1998, Ustron-Jaszowiec, Poland

  12. DMSO-induced dehydration of DPPC membranes studied by x-ray diffraction, small angle neutron scattering and calorimetry

    International Nuclear Information System (INIS)

    Kiselev, M.A.; Kiselev, A.M.; Lesieur, P.; Grabielle-Madelmond, C.; Ollivon, M.

    1998-01-01

    The properties of dimethyl sulfoxide (DMSO), a cryoprotector well known for its biological and therapeutic applications, were investigated on lipid membranes by x-ray diffraction, differential scanning calorimetry (DSC) and small angle neutron scattering (SANS). The DSC study of water freezing and melting of ice was performed in the ternary system which consists of 1,2-dipalmitoyl-sn-glycero-3-phosphatidylcholine (DPPC)/DMSO/water system. The influence of DMSO on the DPPC membrane structure was established in the excess of solvent in the region of DMSO mole fraction from 0.0 to 1.0. The methods applied demonstrated the differences in the membrane structure in three sub-regions of DMSO mole fraction (X DMSO ) from 0.0 to 0.3 for the first, from 0.3 to 0.9 for the second, and from 0.9 to 1.0 for the third sub-region. The results for 0.0 ≤ X DMSO ≤ 0.3 can be explained in the framework of DMSO-induced dehydration of intermembrane space

  13. The Application of Neutron and X-Ray Techniques to Analyze Works of Art: Examples from The Unvarnished Truth Project

    Science.gov (United States)

    MacDonald, Brandi Lee

    2017-01-01

    When considered as an object, a painting consists of multiple components that, when analyzed together, have a unique story to tell about the artist, their practice, and the history of the work of art. Techniques traditionally applied in physics, including neutron-, x-radiographic and near-infrared imaging, and surface elemental analysis via x-ray fluorescence, are useful for generating significant insight into works of art. By examining the supporting material, grounds, pigments, and varnishes that a painter chose to utilize, we generate new knowledge regarding the composition, context, and decision-making involved in the creation of a work. The project `The Unvarnished Truth: exploring the material history of paintings' is an interdisciplinary initiative that incorporated the expertise of forensic art historians, conservation scientists, physicists, and biomedical engineers. Through the technical analysis of nine paintings from the McMaster Museum of Art permanent collection, we explored research questions related to painting technique, attribution, authenticity, connoisseurship, and object condition and stability. The paintings span over 500 years of European art history, and include works from Vincent Van Gogh, Alexander Rodchenko, and A. van der Neer. This project highlights the multitude of ways in which micro- and non-destructive methods can be used to answer art historical questions. This project is supported by grants from Canadian Heritage and Ontario Arts Council.

  14. Photo neutron dose equivalent rate in 15 MV X-ray beam from a Siemens Primus Linac

    Directory of Open Access Journals (Sweden)

    A Ghasemi

    2015-01-01

    Full Text Available Fast and thermal neutron fluence rates from a 15 MV X-ray beams of a Siemens Primus Linac were measured using bare and moderated BF 3 proportional counter inside the treatment room at different locations. Fluence rate values were converted to dose equivalent rate (DER utilizing conversion factors of American Association of Physicist in Medicine′s (AAPM report number 19. For thermal neutrons, maximum and minimum DERs were 3.46 × 10 -6 (3 m from isocenter in +Y direction, 0 × 0 field size and 8.36 × 10 -8 Sv/min (in maze, 40 × 40 field size, respectively. For fast neutrons, maximum DERs using 9" and 3" moderators were 1.6 × 10 -5 and 1.74 × 10 -5 Sv/min (2 m from isocenter in +Y direction, 0 × 0 field size, respectively. By changing the field size, the variation in thermal neutron DER was more than the fast neutron DER and the changes in fast neutron DER were not significant in the bunker except inside the radiation field. This study showed that at all points and distances, by decreasing field size of the beam, thermal and fast neutron DER increases and the number of thermal neutrons is more than fast neutrons.

  15. Correlation methods in optical metrology with state-of-the-art x-ray mirrors

    Science.gov (United States)

    Yashchuk, Valeriy V.; Centers, Gary; Gevorkyan, Gevork S.; Lacey, Ian; Smith, Brian V.

    2018-01-01

    The development of fully coherent free electron lasers and diffraction limited storage ring x-ray sources has brought to focus the need for higher performing x-ray optics with unprecedented tolerances for surface slope and height errors and roughness. For example, the proposed beamlines for the future upgraded Advance Light Source, ALS-U, require optical elements characterized by a residual slope error of optics with a length of up to one meter. However, the current performance of x-ray optical fabrication and metrology generally falls short of these requirements. The major limitation comes from the lack of reliable and efficient surface metrology with required accuracy and with reasonably high measurement rate, suitable for integration into the modern deterministic surface figuring processes. The major problems of current surface metrology relate to the inherent instrumental temporal drifts, systematic errors, and/or an unacceptably high cost, as in the case of interferometry with computer-generated holograms as a reference. In this paper, we discuss the experimental methods and approaches based on correlation analysis to the acquisition and processing of metrology data developed at the ALS X-Ray Optical Laboratory (XROL). Using an example of surface topography measurements of a state-of-the-art x-ray mirror performed at the XROL, we demonstrate the efficiency of combining the developed experimental correlation methods to the advanced optimal scanning strategy (AOSS) technique. This allows a significant improvement in the accuracy and capacity of the measurements via suppression of the instrumental low frequency noise, temporal drift, and systematic error in a single measurement run. Practically speaking, implementation of the AOSS technique leads to an increase of the measurement accuracy, as well as the capacity of ex situ metrology by a factor of about four. The developed method is general and applicable to a broad spectrum of high accuracy measurements.

  16. COMMON PATTERNS IN THE EVOLUTION BETWEEN THE LUMINOUS NEUTRON STAR LOW-MASS X-RAY BINARY SUBCLASSES

    International Nuclear Information System (INIS)

    Fridriksson, Joel K.; Homan, Jeroen; Remillard, Ronald A.

    2015-01-01

    The X-ray transient XTE J1701–462 was the first source observed to evolve through all known subclasses of low-magnetic-field neutron star low-mass X-ray binaries (NS-LMXBs), as a result of large changes in its mass accretion rate. To investigate to what extent similar evolution is seen in other NS-LMXBs we have performed a detailed study of the color–color and hardness–intensity diagrams (CDs and HIDs) of Cyg X-2, Cir X-1, and GX 13+1—three luminous X-ray binaries, containing weakly magnetized neutron stars, known to exhibit strong secular changes in their CD/HID tracks. Using the full set of Rossi X-ray Timing Explorer Proportional Counter Array data collected for the sources over the 16 year duration of the mission, we show that Cyg X-2 and Cir X-1 display CD/HID evolution with close similarities to XTE J1701–462. Although GX 13+1 shows behavior that is in some ways unique, it also exhibits similarities to XTE J1701–462, and we conclude that its overall CD/HID properties strongly indicate that it should be classified as a Z source, rather than as an atoll source. We conjecture that the secular evolution of Cyg X-2, Cir X-1, and GX 13+1—illustrated by sequences of CD/HID tracks we construct—arises from changes in the mass accretion rate. Our results strengthen previous suggestions that within single sources Cyg-like Z source behavior takes place at higher luminosities and mass accretion rates than Sco-like Z behavior, and lend support to the notion that the mass accretion rate is the primary physical parameter distinguishing the various NS-LMXB subclasses

  17. COMMON PATTERNS IN THE EVOLUTION BETWEEN THE LUMINOUS NEUTRON STAR LOW-MASS X-RAY BINARY SUBCLASSES

    Energy Technology Data Exchange (ETDEWEB)

    Fridriksson, Joel K. [Anton Pannekoek Institute for Astronomy, University of Amsterdam, Science Park 904, 1098 XH Amsterdam (Netherlands); Homan, Jeroen; Remillard, Ronald A., E-mail: J.K.Fridriksson@uva.nl [Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States)

    2015-08-10

    The X-ray transient XTE J1701–462 was the first source observed to evolve through all known subclasses of low-magnetic-field neutron star low-mass X-ray binaries (NS-LMXBs), as a result of large changes in its mass accretion rate. To investigate to what extent similar evolution is seen in other NS-LMXBs we have performed a detailed study of the color–color and hardness–intensity diagrams (CDs and HIDs) of Cyg X-2, Cir X-1, and GX 13+1—three luminous X-ray binaries, containing weakly magnetized neutron stars, known to exhibit strong secular changes in their CD/HID tracks. Using the full set of Rossi X-ray Timing Explorer Proportional Counter Array data collected for the sources over the 16 year duration of the mission, we show that Cyg X-2 and Cir X-1 display CD/HID evolution with close similarities to XTE J1701–462. Although GX 13+1 shows behavior that is in some ways unique, it also exhibits similarities to XTE J1701–462, and we conclude that its overall CD/HID properties strongly indicate that it should be classified as a Z source, rather than as an atoll source. We conjecture that the secular evolution of Cyg X-2, Cir X-1, and GX 13+1—illustrated by sequences of CD/HID tracks we construct—arises from changes in the mass accretion rate. Our results strengthen previous suggestions that within single sources Cyg-like Z source behavior takes place at higher luminosities and mass accretion rates than Sco-like Z behavior, and lend support to the notion that the mass accretion rate is the primary physical parameter distinguishing the various NS-LMXB subclasses.

  18. Abstracts of the 8th Conference on total reflection x-ray fluorescence analysis and related methods

    International Nuclear Information System (INIS)

    Wobrauschek, P.

    2000-01-01

    The 8. conference on total reflection x-ray fluorescence analysis and related methods held from 25.9 to 29.9.2000 contains 79 abstracts about x-ray fluorescence analysis (XRFA) as a powerful tool used for industrial production, geological prospecting and for environmental control. Total reflection x-ray fluorescence spectroscopy is also a tool used for chemical analysis in medicine, industry and research. (E.B.)

  19. Development of X-ray and ion diagnostic methods for plasma focus research

    International Nuclear Information System (INIS)

    Sadowski, M.

    1986-12-01

    A review of experimental methods used for investigation of X-rays and ion-beams emmited from plasma focus facilities is presented. The research program has been realized at the Institute for Nuclear Studies in Swierk and at the Institut fuer Plasmaforschung in Stuttgart, within the frames of an international co-operation. The studies on ion emission from different PF facilities are reviewed. The application of CN-films with Al-filters and of different ion-pinhole cameras is described. The use of a Thomson mass-spectrometer adopted for plasma studies is presented. The time-resolved measurements combined with a simultaneous mass- and energy-analysis of the ion beams are also described. The most important results of these studies are summarized. Particular attention is also paid to the studies of the X-ray emission. The use of stereoscopic sets of vacuum pinhole cameras with thin Be-filters is described. The application of X-ray pinhole cameras equipped with miniature scintillators for time-resolved measurements is also presented. The most important results of the X-ray emission studies are summarized. 35 refs., 12 figs. (author)

  20. Assessment of a synchrotron X-ray method for quantitative analysis of calcium hydroxide

    International Nuclear Information System (INIS)

    Williams, P. Jason; Biernacki, Joseph J.; Bai Jianming; Rawn, Claudia J.

    2003-01-01

    Thermogravimetric analysis (TGA) and quantitative X-ray diffraction (QXRD) are widely used to determine the calcium hydroxide (CH) content in cementitious systems containing blends of Portland cement, fly ash, blast furnace slag, silica fume and other pozzolanic and hydraulic materials. These techniques, however, are destructive to cement samples and subject to various forms of error. While precise weight losses can be measured by TGA, extracting information from samples with multiple overlapping thermal events is difficult. And, however, while QXRD can offer easier deconvolution, the accuracy for components below about 5 wt.% is typically poor when a laboratory X-ray source is used. Furthermore, the destructive nature of both techniques prevents using them to study the in situ hydration of a single contiguous sample for kinetic analysis. In an attempt to overcome these problems, the present research evaluated the use of synchrotron X-rays for quantitative analysis of CH. A synchrotron X-ray source was used to develop calibration data for quantification of the amount of CH in mixtures with fly ash. These data were compared to conventional laboratory XRD data for like samples. While both methods were found to offer good quantification, synchrotron XRD (SXRD) provided a broader range of detectability and higher accuracy than laboratory diffraction and removed the subjectivity as compared to TGA analysis. Further, the sealed glass capillaries used with the synchrotron source provided a nondestructive closed, in situ environment for tracking hydrating specimens from zero to any desired age

  1. Solid-state x-ray receptor and method of making same

    International Nuclear Information System (INIS)

    Dorman, A.; Glave, W.K.; Birnbach, C.

    1985-01-01

    An X-ray receptor for producing electrical signals representative of an X-ray image is discussed. An array of semiconductor elements is mounted on at least one support, each element being formed of semiconductor material which is an element of Group 4A of the Periodic Table of Elements or a compound of such an element, or which is at least one element of Group 3A of the Periodic Table of Elements together with at least one element of Group 5A of the Periodic Table of Elements, and having at least one PN junction therein. The array is positioned to receive impinging X-rays and to produce electrical signals in response thereto. Electrical conducting leads are supported on the support, and the electrical signals which are produced by respective ones of the semiconductor elements are coupled to these electrical conducting leads. Output terminals also are supported on the support to provide output image signals; and circuitry including multiplexing circuits additionally is supported on the support for processing and multiplexing the electrical signals from the electrical conducting leads to the output terminals. Also disclosed is a method by which the X-ray receptor is made

  2. Determination of the absolute configuration of (+)-neopentyl-1-d alcohol by neutron and x-ray diffraction analysis.

    Science.gov (United States)

    Yuan, H S; Stevens, R C; Bau, R; Mosher, H S; Koetzle, T F

    1994-12-20

    The absolute configuration of (+)-neopentyl-1-d alcohol, prepared by the reduction of 2,2-dimethylpropanal-1-d by actively fermenting yeast, has been determined to be S by neutron diffraction. The neutron study was carried out on the phthalate half ester of neopentyl-1-d alcohol, crystallized as its strychnine salt. The absolute configuration of the (-)-strychninium cation was first determined by an x-ray anomalous dispersion study of its iodide salt. The chiral skeleton of strychnine then served as a reference from which the absolute configuration of the -O-CHD-C(CH3)3 group of neopentyl phthalate was determined. Difference Fourier maps calculated from the neutron data showed unambiguously that the -O-CHD-C(CH3)3 groups of both independent molecules in the unit cell had the S configuration. This work proves conclusively that the yeast system reduces aldehydes by delivering hydrogen to the re face of the carbonyl group. Crystallographic details: (-)-strychninium (+)-neopentyl-1-d phthalate, space group P2(1) (monoclinic), a = 18.564(6) A, b = 7.713(2) A, c = 23.361(8) A, beta = 94.18(4) degrees, V = 3336.0(5) A3, Z = 2 (T = 100 K). Final agreement factors are R(F) = 0.073 for 2768 reflections collected at room temperature (x-ray analysis) and R(F) = 0.144 for 960 reflections collected at 100 K (neutron analysis).

  3. X-ray Bursts in Neutron Star and Black Hole Binaries from USA Data: Detections and Upper Limits

    Energy Technology Data Exchange (ETDEWEB)

    Tournear, Derek M

    2003-02-18

    Narayan and Heyl (2002) have developed a theoretical framework to convert suitable upper limits on type I X-ray bursts from accreting black hole candidates (BHCs) into evidence for an event horizon. However, no appropriate observational limit exists in the literature. In this paper we survey 2101.2 ks of data from the Unconventional Stellar Aspect (USA) X-ray timing experiment and 5142 ks of data from the Rossi X-ray Timing Explorer (RXTE) experiment to obtain a formal constraint of this type. 1122 ks of neutron star data yield a population averaged mean burst rate of 1.69 x 10{sup -5} bursts s{sup -1} while 6081 ks of BHC data yield a 95% confidence level upper limit of 4.9 x 10{sup -7} bursts s{sup -1}. This is the first published limit of this type for Black Hole Candidates. Applying the theoretical framework of Narayan and Heyl (2002) we calculate regions of unstable luminosity where the neutron stars are expected to burst and the BHCs would be expected to burst if they had a surface. In this unstable luminosity region 464 ks of neutron star data yield an averaged mean burst rate of 4.1 x 10{sup -5} bursts s{sup -1} and 1512 ks of BHC data yield a 95% confidence level upper limit of 2.0 x 10{sup 6} bursts s{sup -1}, and a limit of > 10 {sigma} that BHCs do not burst with a rate similar to the rate of neutron stars in these unstable regions. This gives further evidence that BHCs do not have surfaces unless there is some new physics occurring on their surface.

  4. Diffractometric method for obtaining of x-ray diffraction patterns of transplutonium element compounds

    International Nuclear Information System (INIS)

    Dubasov, Yu.V.; Aleksandrov, B.M.; Baranov, Yu.I.; Golubev, V.A.; Nikolaev, V.B.

    1986-01-01

    Method allowing to carry out X-ray radiographic investigations of powders of high radioactive α-sources (transuranium and transplutonium compounds) by the diffractometric method have been developed. The method is tested for three americium compounds crystallizing in different syngonies - dioxide, formiate, oxalate. The substance quantity necessary for analysis is 0.5-1 mg. The investigations can be carried out with diffractometers of general purpose of DRON-UMI and DRON-20 types

  5. Applications of the Warren-Averbach method of X-ray diffraction line profile analysis

    International Nuclear Information System (INIS)

    Ichikawa, Rodrigo Uchida

    2013-01-01

    The objective of this work was to develop and implement a methodology of X-ray Line Profile Analysis (XLPA) for the study and determination of the mean crystallite sizes and microstrains in materials. A computer program was developed to speed up the treatment of diffraction peaks and perform the deconvolution utilizing the Stokes method to correct the instrumental contribution in the X-ray diffraction measurements. The XLPA methods used were the Scherrer, Williamson-Hall and Single-Line methods, which can be called real space methods, and the Fourier space method of Warren-Averbach. Furthermore, considering a mathematical modelling it was possible to calculate the crystallite size distribution, considering the log-normal distribution and spherical crystallites. It was possible to demonstrate the proposed theory can provide reliable results evaluating a dispersion parameter. The methodologies described above were applied in two distinct materials: in the alloy Zircaloy-4 and in ZnO. (author)

  6. A wavelet-based Gaussian method for energy dispersive X-ray fluorescence spectrum

    Directory of Open Access Journals (Sweden)

    Pan Liu

    2017-05-01

    Full Text Available This paper presents a wavelet-based Gaussian method (WGM for the peak intensity estimation of energy dispersive X-ray fluorescence (EDXRF. The relationship between the parameters of Gaussian curve and the wavelet coefficients of Gaussian peak point is firstly established based on the Mexican hat wavelet. It is found that the Gaussian parameters can be accurately calculated by any two wavelet coefficients at the peak point which has to be known. This fact leads to a local Gaussian estimation method for spectral peaks, which estimates the Gaussian parameters based on the detail wavelet coefficients of Gaussian peak point. The proposed method is tested via simulated and measured spectra from an energy X-ray spectrometer, and compared with some existing methods. The results prove that the proposed method can directly estimate the peak intensity of EDXRF free from the background information, and also effectively distinguish overlap peaks in EDXRF spectrum.

  7. Long-term storage method for soft X-ray irradiated 'Hyuganatsu' pollen

    International Nuclear Information System (INIS)

    Yano, S.; Tanaka, M.; Ohara, N.

    2008-01-01

    The long-term storage conditions for 'Hyuganatsu ' pollen that had been irradiated with soft X-rays was examined. This study, was aimed at production of 'Tosa-buntan' without formation of nuclear fruit. 1. We evaluated the germination rate of pollen that had been irradiated with soft X-ray (500 or 1,000 Gy) and stored at 3 deg C, -20 deg C, and -40 deg C. The germination rate was the same as that of unirradiated pollen, even after storage for 1 year. Soft X-ray irradiation did not influence the storage attributes of pollen. 2. In unirradiated pollen and pollen that had been irradiated with soft X-ray (500 or 1,000 Gy), temperature conditions necessary for storing from 3 months to 1 year were -20 deg C or less, and pollen stored at -40 deg C had a higher germination rate after 1 year. 3. The germination rate was 1% or less in 4 months if silica gel was sealed into a gas barrier bag with 1,000 Gy-irradiated pollen at a rate of 10:1 (w/w). The ability to germinate was completely lost after 1 year in these conditions. 4. We evaluated the effect of sealing methods on 1,000 Gy-irradiated pollen stored at -20 deg C. There was no difference in germination rates among pollen stored in gas-barrier bags, vacuum-packaged pollen, and pollen stored with nitrogen in gas-barrier bags. Moreover, the germination rate of 750 Gy-irradiated pollen stored at -20 deg C decreased from 3 months onwards when pollen was stored with a free-oxygen absorber (Ageless ZP). 5. Pollen that was treated with acetone before or after soft X-ray irradiation (750 Gy) withstood long-term storage of 1 year. Long-term storage was possible if pollen was stored at -20 deg C, as is the case for rough pollen

  8. Stellar X-ray sources

    International Nuclear Information System (INIS)

    Katz, J.I.; Washington Univ., St. Louis, MO

    1988-01-01

    I Review some of the salient accomplishments of X-rap studies of compact objects. Progress in this field has closely followed the improvement of observational methods, particularly in angular resolution and duration of exposure. Luminous compact X-ray sources are accreting neutron stars or black holes. Accreting neutron stars may have characteristic temporal signatures, but the only way to establish that an X-ray source is a black hole is to measure its mass. A rough phenomenological theory is succesful, but the transport of angular momentum in accretion flows is not onderstood. A number of interesting complications have been observed, including precessing accretion discs, X-ray bursts, and the acceleration of jets in SS433. Many puzzles remain unsolved, including the excitation of disc precession, the nature of the enigmatic A- and gamma-ray source Cyg X-3, the mechanism by which slowly spinning accreting neutron stars lose angular momentum, and the superabundance of X-ray sources in globular clusters. 41 refs.; 5 figs

  9. Envelope method for background elimination from X-ray fluorescence spectra

    International Nuclear Information System (INIS)

    Monakhov, V.V.; Naumenko, P.A.; Chashinskaya, O.A.

    2006-01-01

    The influence of the background noise caused by Bremsstrahlung on the accuracy of the envelope method at x-ray fluorescence spectra processing is studied. This is carried out by the example of model spectra at different forms of Bremsstrahlung noise as well as at the presence of background noise in spectra. The interpolation by parabolic splines is used for the estimation of the error of the envelope method for the elimination of continuos background noise. It is found out that the error of the proposed method constitutes decimal parts of percent. It is shown that the envelope method is the effective technique for the elimination of the continuous Bremsstrahlung from x-ray fluorescence spectra of the first order [ru

  10. Residual stress measurement by X-ray diffraction with the Gaussian curve method and its automation

    International Nuclear Information System (INIS)

    Kurita, M.

    1987-01-01

    X-ray technique with the Gaussian curve method and its automation are described for rapid and nondestructive measurement of residual stress. A simplified equation for measuring the stress by the Gaussian curve method is derived because in its previous form this method required laborious calculation. The residual stress can be measured in a few minutes, depending on materials, using an automated X-ray stress analyzer with a microcomputer which was developed in the laboratory. The residual stress distribution of a partially induction hardened and tempered (at 280 0 C) steel bar was measured with the Gaussian curve method. A sharp residual tensile stress peak of 182 MPa appeared right outside the hardened region at which fatigue failure is liable to occur

  11. First examination of CASCADE-X-ray-detector and measurement of neutron-mirrorneutron-oscillation; Erste Untersuchungen zum CASCADE-Roentgendetektor und Messung zur Neutron-Spiegelneutron-Oszillation

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, B.

    2007-02-07

    The detection of X-radiation is of utmost importance for both fundamental physics and medical diagnostics. This work investigates whether or not the CASCADE detector working principle, first developed for the detection of neutrons, can be adapted for the detection of X-rays. This modular detector concept combines the use of a solid neutron or X-ray converter with the advantages of a counting gas detector. Thus, it gives the possibility to optimize efficiency, dynamics and spatial resolution independently. Firstly, it is necessary to find a suitable converter material that allows for the best possible detector efficiency. In order to do so, a mathematical model of the complete detector system was developed that yields the total efficiency for any given material. Respecting technical constraints, gold and gadolinium showed to be favorable choices. Based on these theoretical considerations a prototype of a CASCADE X-ray detector was built, and measurements for the determination of this detector's efficiency were conducted. In the second part of this work a CASCADE neutron detector was used to conduct the first measurement the neutron-mirrorneutron oscillation time. Mirrormatter was proposed in 1956 by Lee and Yang to allow for symmetry in the description of the universe despite the existence of parity violation. By using neutrons it was possible to determine a lower limit for the oscillation time in this work. (orig.)

  12. Mineralogical analysis of clays in hardsetting soil horizons, by X-ray fluorescence and X-ray diffraction using Rietveld method

    International Nuclear Information System (INIS)

    Prandel, L.V.; Saab, S.C.; Brinatti, A.M.; Giarola, N.F.B.; Leite, W.C.; Cassaro, F.A.M.

    2014-01-01

    Diffraction and spectroscopic techniques have been shown to be suitable for obtaining physical and mineralogical properties in polycrystalline soil samples, and also in their precursor compounds. For instance, the X-ray fluorescence (XRF) spectroscopy allows obtaining the elemental composition of an investigated sample, while the X-ray diffraction (XRD) technique permits obtaining qualitative and quantitative composition of the soil minerals through the Rietveld method (RM). In this study Yellow Latosol (Oxisol), Yellow Argisol (Ultisol) and Gray Argisol (Ultisol) soil samples, classified as “hardsetting soils”, extracted from areas located at Northeast and Southeast of Brazilian coast were investigated. The soils and their fractions were analyzed in an EDX-700 and an XRD-6000 (Cu K α radiation). XRF results indicate high percentages of Si and Al, and small percentage of Fe and Ti in the investigated samples. The DRX data and RM indicate that there was a predominance of kaolinite and halloysite minerals (kaolin group minerals) in the clay fractions, which are presumably responsible for the formation of kaolinitic plasma in these soils. Also, the obtained results showed that the XRF, XRD techniques and RM were very helpful for investigating the mineralogical composition of a hardsetting soil. - Highlights: ► Elemental composition of soil samples through X-Ray fluorescence. ► Mineralogical quantification through X-ray diffraction and Rietveld method. ► Oxisol and Ultisol, Brazil ‘Barreiras’ formation. ► High amounts of Si and Al oxides and low amounts of Fe and Ti oxides. ► Predominance of kaolinite in the clay fraction

  13. Research at big facilities on actinides: How neutrons and synchrotron x-rays can help our understanding

    International Nuclear Information System (INIS)

    Lander, G.H.

    2014-01-01

    Neutron scattering was a by-product of the Manhattan Project, as it started by using neutron beams emerging from the reactors produced by that project. Seventy years later, neutron scattering is a tool used by many scientists, across many different disciplines, to try to understand the microscopic properties of materials. It can also give unique answers to problems involving actinides. ; X-rays, of course, date even further back, but it was not until the 1970s that synchrotron radiation was widely available. Now synchrotron radiation is a tool widely used in the study of actinides across a variety of different fields. ; The basic properties of these two probes will be presented and contrasted. Some of the ways these techniques have helped us understand the actinides will be presented

  14. Synchrotron x-ray methods in studies of thin organic film structure

    International Nuclear Information System (INIS)

    Gentle, I.

    2002-01-01

    Full text: In recent years, the study of the structures of organic films as thin as a single monolayer has been revolutionized by methods that take advantage of the characteristics of synchrotron radiation. In particular, the methods of grazing incidence X-ray diffraction (GIXD) and X-ray reflectivity have led to a number of valuable insights into structural aspects of thin films at molecular resolution. Our group has been studying films formed at the air/water interface as insoluble monolayers and subsequently transferred to solid substrates using either the vertical (Langmuir-Blodgett) or horizontal (Langmuir-Schaeffer) methods. The main aim of these experiments is to exert control over film structure in the direction parallel to the substrate surface. This is highly desirable in order to design devices that exploit the optical and electrooptical properties of functional materials, but is difficult to do. By varying the chemical structure of the film materials and controlling deposition conditions a degree of control is possible, but only using synchrotron methods can it be easily verified. We have also developed a novel method of rapidly collecting data from GIXD measurements by the application of area detection (imaging plates), which has made possible measurements of dynamic processes such as in-situ annealing. Such measurements are not possible using traditional scanning methods. One area of current interest is films composed of porphyrins as functional materials, either alone or as mixed films with fatty acids. We have been investigating ways of assembling porphyrins in such a way as to overcome the tendency to aggregate, and to produce patterning and ordered structures in the plane of the interface. Examples will be given of how film composition and deposition method affects the final structure, and of how X-ray methods can be used to elucidate both the structures and the mechanisms. Copyright (2002) Australian X-ray Analytical Association Inc

  15. Image combination enhancement method for X-ray compton back-scattering security inspection body scanner

    International Nuclear Information System (INIS)

    Wang Huaiying; Zhang Yujin; Yang Lirui; Li Dong

    2011-01-01

    As for X-ray Compton Back-Scattering (CBS) body scanner, image clearness is very important for the performance of detecting the contraband hidden on the body. A new image combination enhancement method is provided based on characteristics of CBS body images and points of human vision. After processed by this method, the CBS image will be obviously improved with clear levels, distinct outline and uniform background. (authors)

  16. Method and multichannel equipment for chemical analysis by X-ray emission

    International Nuclear Information System (INIS)

    Bacso, J.; Horkay, Gy.; Kalinka, G.; Kertesz, Zs.; Kiss Varga, M.; Lakatos, T.; Mathe, Gy.; Paal, A.; Sulik, B.

    1978-01-01

    In the patent a simple method and an apparatus are described for chemical analysis based on X-ray emission generated by irradiation. The concentrations of pre-selected elements can be determined easily by this method using an equipment containing microprocessor. The number of channels and the elements to be determined can be modified by a simple change in the program. (Sz.J.)

  17. Relative cataractogenic effects of X rays, fission-spectrum neutrons, and 56Fe particles: A comparison with mitotic effects

    International Nuclear Information System (INIS)

    Riley, E.F.; Lindgren, A.L.; Andersen, A.L.; Miller, R.C.; Ainsworth, E.J.

    1991-01-01

    The eyes of Sprague-Dawley rats were irradiated with doses of 2.5-10 Gy 250-kVp X rays, 1.25-2.25 Gy fission-spectrum neutrons (approximately 0.85 MeV), or 0.1-2.0 Gy 600-MeV/A 56Fe particles. Lens opacifications were evaluated for 51-61 weeks following X and neutron irradiations and for 87 weeks following X and 56Fe-particle irradiations. Average stage of opacification was determined relative to time after irradiation, and the time required for 50% of the irradiated lenses to achieve various stages (T50) was determined as a function of radiation dose. Data from two experiments were combined in dose-effect curves as T50 experimental values taken as percentages of the respective T50 control values (T50-% control). Simple exponential curves best describe dose responsiveness for both high-LET radiations. For X rays, a shallow dose-effect relationship (shoulder) up to 4.5 Gy was followed at higher doses by a steeper exponential dose-effect relationship. As a consequence, RBE values for the high-LET radiations are dose dependent. Dose-effect curves for cataracts were compared to those for mitotic abnormalities observed when quiescent lens epithelial cells were stimulated mechanically to proliferate at various intervals after irradiation. Neutrons were about 1.6-1.8 times more effective than 56Fe particles for inducing both cataracts and mitotic abnormalities. For stage 1 and 2 cataracts, the X-ray Dq was 10-fold greater and the D0 was similar to those for mitotic abnormalities initially expressed after irradiation

  18. The methods for detecting multiple small nodules from 3D chest X-ray CT images

    International Nuclear Information System (INIS)

    Hayase, Yosuke; Mekada, Yoshito; Mori, Kensaku; Toriwaki, Jun-ichiro; Natori, Hiroshi

    2004-01-01

    This paper describes a method for detecting small nodules, whose CT values and diameters are more than -600 Hounsfield unit (H.U.) and 2 mm, from three-dimensional chest X-ray CT images. The proposed method roughly consists of two submodules: initial detection of nodule candidates by discriminating between nodule regions and other regions such as blood vessels or bronchi using a shape feature computed from distance values inside the regions and reduction of false positive (FP) regions by using a minimum directional difference filter called minimum directional difference filter (Min-DD) changing its radius suit to the size of the initial candidates. The performance of the proposed method was evaluated by using seven cases of chest X-ray CT images including six abnormal cases where multiple lung cancers are observed. The experimental results for nodules (361 regions in total) showed that sensitivity and FP regions are 71% and 7.4 regions in average per case. (author)

  19. X-ray holography

    International Nuclear Information System (INIS)

    Faigel, G.; Tegze, M.; Belakhovsky, M.; Marchesini, S.; Bortel, G.

    2003-01-01

    In the last decade holographic methods using hard X-rays were developed. They are able to resolve atomic distances, and can give the 3D arrangement of atoms around a selected element. Therefore, hard X-ray holography has potential applications in chemistry, biology and physics. In this article we give a general description of these methods and discuss the developments in the experimental technique. The capabilities of hard X-ray holography are demonstrated by examples

  20. Hemoglobin redux: combining neutron and X-ray diffraction with mass spectrometry to analyse the quaternary state of oxidized hemoglobins

    Energy Technology Data Exchange (ETDEWEB)

    Mueser, Timothy C., E-mail: timothy.mueser@utoledo.edu; Griffith, Wendell P. [Department of Chemistry, University of Toledo, Toledo, OH 43606 (United States); Kovalevsky, Andrey Y. [Bioscience Division, MS M888, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Guo, Jingshu; Seaver, Sean [Department of Chemistry, University of Toledo, Toledo, OH 43606 (United States); Langan, Paul [Department of Chemistry, University of Toledo, Toledo, OH 43606 (United States); Bioscience Division, MS M888, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Hanson, B. Leif [Department of Chemistry, University of Toledo, Toledo, OH 43606 (United States)

    2010-11-01

    X-ray and neutron diffraction studies of cyanomethemoglobin are being used to evaluate the structural waters within the dimer–dimer interface involved in quaternary-state transitions. Improvements in neutron diffraction instrumentation are affording the opportunity to re-examine the structures of vertebrate hemoglobins and to interrogate proton and solvent position changes between the different quaternary states of the protein. For hemoglobins of unknown primary sequence, structural studies of cyanomethemoglobin (CNmetHb) are being used to help to resolve sequence ambiguity in the mass spectra. These studies have also provided additional structural evidence for the involvement of oxidized hemoglobin in the process of erythrocyte senescence. X-ray crystal studies of Tibetan snow leopard CNmetHb have shown that this protein crystallizes in the B state, a structure with a more open dyad, which possibly has relevance to RBC band 3 protein binding and erythrocyte senescence. R-state equine CNmetHb crystal studies elaborate the solvent differences in the switch and hinge region compared with a human deoxyhemoglobin T-state neutron structure. Lastly, comparison of histidine protonation between the T and R state should enumerate the Bohr-effect protons.

  1. Nanostructure of polymer monolayer and polyelectrolyte brush at air/water interface by X-ray and neutron reflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Matsuoka, Hideki; Mouri, Emiko; Matsumoto, Kozo [Kyoto Univ., Dept. of Polymer Chemistry, Kyoto (Japan)

    2003-03-01

    The nanostructure of amphiphilic diblock copolymer monolayer on water was directly investigated by in situ X-ray and neutron reflectivity techniques. The diblock copolymer consists of polysilacyclobutane, which is very flexible, as a hydrophobic block and polymethacrylic acid, an anionic polymer, as a hydrophilic block. The polymers with shorter hydrophilic segment formed a very smooth and uniform monolayer with hydrophobic layer on water and dense hydrophilic layer under the water. But the longer hydrophilic segment polymer formed three-layered monolayer with polyelectrolyte brush in addition to hydrophobic and dense hydrophilic layers. The dense hydrophilic layer is thought to be formed to avoid a contact between hydrophobic polymer layer and water. Its role is something like a 'carpet'. An additional interesting information is that the thickness of the 'carpet layer' is almost 15A, independent the surface pressure and hydrophilic polymer length. Highly quantitative information was obtained about the nanostructure of polymer brush under water by neutron reflectometry with the aid of contrast variation technique. X-ray and neutron reflectivity is a very powerful technique to investigate the nanostructure of surface and interfaces, which is important not only for surface nanotechnology but also industrial and medical applications. (author)

  2. First spin-resolved electron distributions in crystals from combined polarized neutron and X-ray diffraction experiments

    Directory of Open Access Journals (Sweden)

    Maxime Deutsch

    2014-05-01

    Full Text Available Since the 1980s it has been possible to probe crystallized matter, thanks to X-ray or neutron scattering techniques, to obtain an accurate charge density or spin distribution at the atomic scale. Despite the description of the same physical quantity (electron density and tremendous development of sources, detectors, data treatment software etc., these different techniques evolved separately with one model per experiment. However, a breakthrough was recently made by the development of a common model in order to combine information coming from all these different experiments. Here we report the first experimental determination of spin-resolved electron density obtained by a combined treatment of X-ray, neutron and polarized neutron diffraction data. These experimental spin up and spin down densities compare very well with density functional theory (DFT calculations and also confirm a theoretical prediction made in 1985 which claims that majority spin electrons should have a more contracted distribution around the nucleus than minority spin electrons. Topological analysis of the resulting experimental spin-resolved electron density is also briefly discussed.

  3. First spin-resolved electron distributions in crystals from combined polarized neutron and X-ray diffraction experiments.

    Science.gov (United States)

    Deutsch, Maxime; Gillon, Béatrice; Claiser, Nicolas; Gillet, Jean-Michel; Lecomte, Claude; Souhassou, Mohamed

    2014-05-01

    Since the 1980s it has been possible to probe crystallized matter, thanks to X-ray or neutron scattering techniques, to obtain an accurate charge density or spin distribution at the atomic scale. Despite the description of the same physical quantity (electron density) and tremendous development of sources, detectors, data treatment software etc., these different techniques evolved separately with one model per experiment. However, a breakthrough was recently made by the development of a common model in order to combine information coming from all these different experiments. Here we report the first experimental determination of spin-resolved electron density obtained by a combined treatment of X-ray, neutron and polarized neutron diffraction data. These experimental spin up and spin down densities compare very well with density functional theory (DFT) calculations and also confirm a theoretical prediction made in 1985 which claims that majority spin electrons should have a more contracted distribution around the nucleus than minority spin electrons. Topological analysis of the resulting experimental spin-resolved electron density is also briefly discussed.

  4. The smoothing and fast Fourier transformation of experimental X-ray and neutron data from amorphous materials

    International Nuclear Information System (INIS)

    Dixon, M.; Wright, A.C.; Hutchinson, P.

    1977-01-01

    The application of fast Fourier transformation techniques to the analysis of experimental X-ray and neutron diffraction patterns from amorphous materials is discussed and compared with conventional techniques using Filon's quadrature. The fast Fourier transform package described also includes cubic spline smoothing and has been extensively tested, using model data to which statistical errors have been added by means of a pseudo-random number generator with Gaussian shaper. Neither cubic spline nor hand smoothing has much effect on the resulting transform since the noise removed is of too high a frequency. (Auth.)

  5. X-ray absorption spectroscopy and neutron diffraction study of the perovskite-type rare-earth cobaltites

    Science.gov (United States)

    Sikolenko, V.; Efimova, E.; Franz, A.; Ritter, C.; Troyanchuk, I. O.; Karpinsky, D.; Zubavichus, Y.; Veligzhanin, A.; Tiutiunnikov, S. I.; Sazonov, A.; Efimov, V.

    2018-05-01

    Correlations between local and long-range structure distortions in the perovskite-type RE1-xSrxCoO3-δ (RE = La, Pr, Nd; x = 0.0 and 0.5) compounds have been studied at room temperature by extended X-ray absorption fine structure (EXAFS) at the Co K-edge and high-resolution neutron powder diffraction (NPD). The use of two complementary experimental techniques allowed us to explore the influence of the type of rare-earth element and strontium substitution on unusual behavior of static and dynamic features of both the Co-O bond lengths.

  6. Chemical protection against gastrointestinal radiation injury in mice by WR 2822, WR 2823, or WR 109342 after 4 MeV x ray or fission neutron irradiation

    International Nuclear Information System (INIS)

    Connor, A.M.; Sigdestad, C.P.

    1982-01-01

    Three compounds were tested for their radioprotective properties against the effects of 4 MeV X rays or fission neutron irradiation. The endpoints tested were lethality, intestinal crypt survival, and DNA synthesizing cellularity. Two of the compounds tested; S-2(4-aminobutylamino) ethylphosphorothioc acid (WR 2822) and the aminopentylamino derivative (WR 109342). All drugs were administered via intraperitoneal injections at their approximately maximum tolerated dose. WR 2822 was shown to have a slight protective effect against X rays and neutrons. The dose modification factor (DMF) for gastrointestinal death (LD/sub 50(6)/) was 1.23 for X rays and 1.51 for neutrons. The assay for intestinal crypt survival produced DMF's of 1.44 (X rays) and 1.4 (neutrons). WR 2823 also showed a protective action in these assays. The DMF for LD/sub 50(6)/ was 1.32 (X rays) and 1.42 (neutrons). WR 109342 was found to be extremely toxic and had no significant protective effects. All three drugs were more toxic and demonstrated less protection in most of these assays than the benchmark radioprotective agent WR 2721, although WR 2822 protected against lethal effects of fission neutrons almost as well as WR 2721. Both WR 2822 and WR 2823 produced greater protection in the crypt survival assays for fission neutron irradiation than WR 2721

  7. A NEW METHOD TO QUANTIFY X-RAY SUBSTRUCTURES IN CLUSTERS OF GALAXIES

    Energy Technology Data Exchange (ETDEWEB)

    Andrade-Santos, Felipe; Lima Neto, Gastao B.; Lagana, Tatiana F. [Departamento de Astronomia, Instituto de Astronomia, Geofisica e Ciencias Atmosfericas, Universidade de Sao Paulo, Geofisica e Ciencias Atmosfericas, Rua do Matao 1226, Cidade Universitaria, 05508-090 Sao Paulo, SP (Brazil)

    2012-02-20

    We present a new method to quantify substructures in clusters of galaxies, based on the analysis of the intensity of structures. This analysis is done in a residual image that is the result of the subtraction of a surface brightness model, obtained by fitting a two-dimensional analytical model ({beta}-model or Sersic profile) with elliptical symmetry, from the X-ray image. Our method is applied to 34 clusters observed by the Chandra Space Telescope that are in the redshift range z in [0.02, 0.2] and have a signal-to-noise ratio (S/N) greater than 100. We present the calibration of the method and the relations between the substructure level with physical quantities, such as the mass, X-ray luminosity, temperature, and cluster redshift. We use our method to separate the clusters in two sub-samples of high- and low-substructure levels. We conclude, using Monte Carlo simulations, that the method recuperates very well the true amount of substructure for small angular core radii clusters (with respect to the whole image size) and good S/N observations. We find no evidence of correlation between the substructure level and physical properties of the clusters such as gas temperature, X-ray luminosity, and redshift; however, analysis suggest a trend between the substructure level and cluster mass. The scaling relations for the two sub-samples (high- and low-substructure level clusters) are different (they present an offset, i.e., given a fixed mass or temperature, low-substructure clusters tend to be more X-ray luminous), which is an important result for cosmological tests using the mass-luminosity relation to obtain the cluster mass function, since they rely on the assumption that clusters do not present different scaling relations according to their dynamical state.

  8. A comparative study of neutron activation analysis and proton-induced X-ray emission analysis for the determination of heavy metals in estuarine sediments

    Science.gov (United States)

    Randle, K.; Al-Jundi, J.; Mamas, C. J. V.; Sokhi, R. S.; Earwaker, L. G.

    1993-06-01

    Our work on heavy metals in the estuarine environment has involved the use of two multielement techniques: neutron activation analysis (NAA) and proton-induced X-ray emission (PIXE) analysis. As PIXE is essentially a surface analytical technique problems may arise due to sample inhomogeneity and surface roughness. In order to assess the contribution of these effects we have compared the results from PIXE analysis with those from a technique which analyzes a larger bulk sample rather than just the surface. An obvious method was NAA. A series of sediment samples containing particles of variable diameter were compared. Pellets containing a few mg of sediment were prepared from each sample and analyzed by the PIXE technique using both an absolute and a comparitive method. For INAA the rest of the sample was then irradiated with thermal neutrons and element concentrations determined from analyses of the subsequent gamma-ray spectrum. Results from the two methods are discussed.

  9. A method of measuring gold nanoparticle concentrations by x-ray fluorescence for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Wu Di; Li Yuhua; Wong, Molly D.; Liu Hong [Center for Bioengineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, Oklahoma 73019 (United States)

    2013-05-15

    Purpose: This paper reports a technique that enables the quantitative determination of the concentration of gold nanoparticles (GNPs) through the accurate detection of their fluorescence radiation in the diagnostic x-ray spectrum. Methods: Experimentally, x-ray fluorescence spectra of 1.9 and 15 nm GNP solutions are measured using an x-ray spectrometer, individually and within chicken breast tissue samples. An optimal combination of excitation and emission filters is determined to segregate the fluorescence spectra at 66.99 and 68.80 keV from the background scattering. A roadmap method is developed that subtracts the scattered radiation (acquired before the insertion of GNP solutions) from the signal radiation acquired after the GNP solutions are inserted. Results: The methods effectively minimize the background scattering in the spectrum measurements, showing linear relationships between GNP solutions from 0.1% to 10% weight concentration and from 0.1% to 1.0% weight concentration inside a chicken breast tissue sample. Conclusions: The investigation demonstrated the potential of imaging gold nanoparticles quantitatively in vivo for in-tissue studies, but future studies will be needed to investigate the ability to apply this method to clinical applications.

  10. X-ray microprobe analysis of platelets. Principles, methods and review of the literature.

    Science.gov (United States)

    Yarom, R

    1983-01-01

    Platelets are well suited to X-ray microanalysis as there is no need for chemical fixation or sectioning, and the concentrations of calcium and phosphorus are above 10(-3). The principles of the technique, the methods of specimen preparation, instrumental conditions during analysis and ways of quantitation are described. This is followed by a review of published reports and a brief summary of the author's own work in the field.

  11. New applications of elemental analysis methods using X-rays at the INPE Cyclotron

    International Nuclear Information System (INIS)

    Constantinescu, B.; Constantin, F.; Dima, S.; Plostinaru, D.; Popa-Simil, L.

    1990-01-01

    Some results in various samples elemental analysis using PIXE(Particle Induced X-ray Emission) method at INPE U-120 Cyclotron are presented. The main purpose of the research was the determination of metal concentration (Ca,Cr,Mn,Fe,Ni,Cu,Zn) in drug industry materials and products, some tree seeds as environmental pollution indicator, mineral oil and gasoline used in mechanical engineering, cooling water for oil industry equipment. (Author)

  12. Methods for deconvoluting and interpreting complex gamma- and x-ray spectral regions

    International Nuclear Information System (INIS)

    Gunnink, R.

    1983-06-01

    Germanium and silicon detectors are now widely used for the detection and measurement of x and gamma radiation. However, some analysis situations and spectral regions have heretofore been too complex to deconvolute and interpret by techniques in general use. One example is the L x-ray spectrum of an element taken with a Ge or Si detector. This paper describes some new tools and methods that were developed to analyze complex spectral regions; they are illustrated with examples

  13. Determination of calcium and iron in limestone by X-ray fluorescence method

    International Nuclear Information System (INIS)

    Sovtsova, M.K.

    1977-01-01

    The results of determining calcium and iron content in limestone by X-ray fluorescence method are described. The 109 Cd isotape was chosen as a source for excitation, as it permited to reduce the concentration degeneration in the range of large Ca contents due to the larger energy of the primary radiation. The root-mean-square deviation from the data of chemical analysis was +-0.02%FeO and +-0.22%CaO

  14. Rossi X-Ray Timing Explorer Observations of the First Transient Z Source XTE J1701-462: Shedding New Light on Mass Accretion in Luminous Neutron Star X-Ray Binaries

    Science.gov (United States)

    Homan, Jeroen; van der Klis, Michiel; Wijnands, Rudy; Belloni, Tomaso; Fender, Rob; Klein-Wolt, Marc; Casella, Piergiorgio; Méndez, Mariano; Gallo, Elena; Lewin, Walter H. G.; Gehrels, Neil

    2007-02-01

    We report on the first 10 weeks of RXTE observations of the X-ray transient XTE J1701-462 and conclude that it had all the characteristics of the neutron star Z sources, i.e., the brightest persistent neutron star low-mass X-ray binaries. These include the typical Z-shaped tracks traced out in X-ray color diagrams and the variability components detected in the power spectra, such as kHz QPOs and normal and horizontal branch oscillations. XTE J1701-462 is the first transient Z source and provides unique insights into mass accretion rate (m˙) and luminosity dependencies in neutron star X-ray binaries. As its overall luminosity decreased, we observed a switch between two types of Z source behavior, with the branches of the Z track changing their shape and/or orientation. We interpret this as an extreme case of the more moderate long-term changes seen in the persistent Z sources and suggest that they result from changes in m˙. We also suggest that the Cyg-like Z sources (Cyg X-2, GX 5-1, and GX 340+0) are substantially more luminous (>50%) than the Sco-like Z sources (Sco X-1, GX 17+2, and GX 349+2). Adopting a possible explanation for the behavior of kHz QPOs, which involves a prompt as well as a filtered response to changes in m˙, we further propose that changes in m˙ can explain both movement along the Z track and changes in the shape of the Z track. We discuss some consequences of this and consider the possibility that the branches of the Z will smoothly evolve into the branches observed in X-ray color diagrams of the less luminous atoll sources, although not in a way that was previously suggested.

  15. ULX spectra revisited: Accreting, highly magnetized neutron stars as the engines of ultraluminous X-ray sources

    Science.gov (United States)

    Koliopanos, Filippos; Vasilopoulos, Georgios; Godet, Olivier; Bachetti, Matteo; Webb, Natalie A.; Barret, Didier

    2017-12-01

    Aims: In light of recent discoveries of pulsating ultraluminous X-ray sources (ULXs) and recently introduced theoretical schemes that propose neutron stars (NSs) as the central engines of ULXs, we revisit the spectra of eighteen well known ULXs, in search of indications that favour this newly emerging hypothesis. Methods: We examine the spectra from high-quality XMM-Newton and NuSTAR observations. We use a combination of elementary black body and multicolour disk black body (MCD) models, to diagnose the predictions of classic and novel theoretical models of accretion onto NSs. We re-interpret the well established spectral characteristics of ULXs in terms of accretion onto lowly or highly magnetised NSs, and explore the resulting parameter space for consistency. Results: We confirm the previously noted presence of the low-energy (≲6 keV) spectral rollover and argue that it could be interpreted as due to thermal emission. The spectra are well described by a double thermal model consisting of a "hot" (≳1 keV) and a "cool" (≲0.7 keV) multicolour black body (MCB). Under the assumption that the "cool" MCD emission originates in a disk truncated at the neutron star magnetosphere, we find that all ULXs in our sample are consistent with accretion onto a highly magnetised (B ≳ 1012 G) neutron star. We note a strong correlation between the strength of the magnetic field, the temperature of the "hot" thermal component and the total unabsorbed luminosity. Examination of the NuSTAR data supports this interpretation and also confirms the presence of a weak, high-energy (≳15 keV) tail, most likely the result of modification of the MCB emission by inverse Compton scattering. We also note that the apparent high-energy tail, may simply be the result of mismodelling of MCB emission with an atypical temperature (T) versus radius (r) gradient, using a standard MCD model with a fixed gradient of T r-0.75. Conclusions: We have offered a new and robust physical interpretation for

  16. The comparative study of contents of zinc and lead in ore samples of Namtu-Bawdwin Mine by wet analysis, X-ray fluorescence and X-ray diffraction methods

    Energy Technology Data Exchange (ETDEWEB)

    Kyaw-Soe,

    1990-05-01

    Lead-zinc ores taken from Namtu-Bawdwin area had been analyzed by wet processes in the Department of Chemistry, 1984. These ore samples have been analyzed by energy dispersive X-ray fluorescence method in the Department of Physics and X-ray diffraction method is also used to determine elements of lead and zinc compounds in these ore samples in the University`s Research Centre. In brief, we study comparatively the contents of lead and zinc and their compounds using the methods of wet processes, X-ray fluorescence and X-ray diffraction. (author).

  17. In situ x-ray fluorescence and californium-252 neutron activation analysis for marine and terrestrial mineral exploration

    International Nuclear Information System (INIS)

    Wogman, N.A.

    1976-12-01

    Instrumentation has been designed for in situ analysis of marine and terrestrial minerals using the techniques of x-ray fluorescence and neutron activation analysis. The energy-dispersive x-ray fluorescence analyzer allows more than 20 elements to be quantitatively measured at the 10 ppM level in water depths to 300 m. The analyzer consists of a solid cryogen-cooled Si(Li) detector, a 50 mCi 109 Cd or 57 Co excitation source, and an analyzer-computer system for data storage and manipulation. The neutron activation analysis, which is designed to measure up to 30 elements at parts per hundred to ppM levels, utilizes the man-made element 252 Cf as its neutron activation source. The resulting radioelements which emit characteristic gamma radiation are then analyzed in situ during 2- to 200-s counting intervals with Ge(Li) or NaI(T1) detector systems. An extension of this latter technique, which uses a 252 Cf- 235 U fueled subcritical multiplier, is also being studied. The subcritical facility allows the neutrons from the 252 Cf source to be multiplied, thus providing greater neutron flux. Details of these in situ analysis systems, actual in situ spectra, and recorded data are discussed with respect to the detection of minerals at their varying concentration levels. The system response of each illustrates its usefulness for various rapid environmental mineral exploration studies. These techniques can be utilized on terrestrial surfaces and marine or fresh water sediments. 5 figures, 2 tables

  18. Expanded image database of pistachio x-ray images and classification by conventional methods

    Science.gov (United States)

    Keagy, Pamela M.; Schatzki, Thomas F.; Le, Lan Chau; Casasent, David P.; Weber, David

    1996-12-01

    In order to develop sorting methods for insect damaged pistachio nuts, a large data set of pistachio x-ray images (6,759 nuts) was created. Both film and linescan sensor images were acquired, nuts dissected and internal conditions coded using the U.S. Grade standards and definitions for pistachios. A subset of 1199 good and 686 insect damaged nuts was used to calculate and test discriminant functions. Statistical parameters of image histograms were evaluated for inclusion by forward stepwise discrimination. Using three variables in the discriminant function, 89% of test set nuts were correctly identified. Comparable data for 6 human subjects ranged from 67 to 92%. If the loss of good nuts is held to 1% by requiring a high probability to discard a nut as insect damaged, approximately half of the insect damage present in clean pistachio nuts may be detected and removed by x-ray inspection.

  19. Application of X-ray methods to assess grain vulnerability to damage resulting from multiple loads

    International Nuclear Information System (INIS)

    Zlobecki, A.

    1995-01-01

    The aim of the work is to describe wheat grain behavior under multiple dynamic loads with various multipliers. The experiments were conducted on Almari variety grain. Grain moisture was 11, 16, 21 and 28%. A special ram stand was used for loading the grain. The experiments were carried out using an 8 g weight, equivalent to impact energy of 4,6 x 10 -3 [J]. The X-ray method was used to assess damage. The exposure time was 8 minutes with X-ray lamp voltage equal to 15 kV. The position index was used as the measure of the damage. The investigation results were elaborated statistically. Based on the results of analysis of variance, regression analysis, the d-Duncan test and the Kolmogorov-Smirnov test, the damage number was shown to depend greatly on the number of impacts for the whole range of moisture of the grain loaded. (author)

  20. A simple method to improve the quantification accuracy of energy-dispersive X-ray microanalysis

    International Nuclear Information System (INIS)

    Walther, T

    2008-01-01

    Energy-dispersive X-ray spectroscopy in a transmission electron microscope is a standard tool for chemical microanalysis and routinely provides qualitative information on the presence of all major elements above Z=5 (boron) in a sample. Spectrum quantification relies on suitable corrections for absorption and fluorescence, in particular for thick samples and soft X-rays. A brief presentation is given of an easy way to improve quantification accuracy by evaluating the intensity ratio of two measurements acquired at different detector take-off angles. As the take-off angle determines the effective sample thickness seen by the detector this method corresponds to taking two measurements from the same position at two different thicknesses, which allows to correct absorption and fluorescence more reliably. An analytical solution for determining the depth of a feature embedded in the specimen foil is also provided.

  1. Investigation of radiation absorption and X-ray fluorescence properties of medical imaging scintillators by Monte Carlo methods

    International Nuclear Information System (INIS)

    Nikolopoulos, D.; Kandarakis, I.; Cavouras, D.; Valais, I.; Linardatos, D.; Michail, C.; David, S.; Gaitanis, A.; Nomicos, C.; Louizi, A.

    2006-01-01

    X-ray absorption and X-ray fluorescence properties of medical imaging scintillating screens were studied by Monte Carlo methods as a function of the incident photon energy and screen-coating thickness. The scintillating materials examined were Gd 2 O 2 S (GOS) Gd 2 SiO 5 (GSO) YAlO 3 (YAP), Y 3 Al 5 O 12 (YAG), LuSiO 5 (LSO), LuAlO 3 (LuAP) and ZnS. Monoenergetic photon exposures were modeled in the range from 10 to 100 keV. The corresponding ranges of coating thicknesses of the investigated scintillating screens ranged up to 200 mg cm -2 . Results indicated that X-ray absorption and X-ray fluorescence are affected by the incident photon energy and the screen's coating thickness. Regarding incident photon energy, this X-ray absorption and fluorescence was found to exhibit very intense changes near the corresponding K edge of the heaviest element in the screen's scintillating material. Regarding coating thickness, thicker screens exhibited higher X-ray absorption and X-ray fluorescence. Results also indicated that a significant fraction of the generated X-ray fluorescent quanta escape from the scintillating screen. This fraction was found to increase with screen's coating thickness. At the energy range studied, most of the incident photons were found to be absorbed via one-hit photoelectric effect. As a result, the reabsorption of scattered radiation was found to be of rather minor importance; nevertheless this was found to increase with the screen's coating thickness. Differences in X-ray absorption and X-ray fluorescence were found among the various scintillators studied. LSO scintillator was found to be the most attractive material for use in many X-ray imaging applications, exhibiting the best absorption properties in the largest part of the energy range studied. Y-based scintillators were also found to be of significant absorption performance within the low energy ranges

  2. Neutron star crustal plate tectonics. I. Magnetic dipole evolution in millisecond pulsars and low-mass X-ray binaries

    International Nuclear Information System (INIS)

    Ruderman, M.

    1991-01-01

    Crust lattices in spinning-up or spinning-down neutron stars have growing shear stresses caused by neutron superfluid vortex lines pinned to lattice nuclei. For the most rapidly spinning stars, this stress will break and move the crust before vortex unpinning occurs. In spinning-down neutron stars, crustal plates will move an equatorial subduction zone in which the plates are forced into the stellar core below the crust. The opposite plate motion occurs in spinning-up stars. Magnetic fields which pass through the crust or have sources in it move with the crust. Spun-up neutron stars in accreting low-mass X-ray binaries LMXBs should then have almost axially symmetric magnetic fields. Spun-down ones with very weak magnetic fields should have external magnetic fields which enter and leave the neutron star surface only near its equator. The lowest field millisecond radiopulsars seem to be orthogonal rotators implying that they have not previously been spun-up in LMXBs but are neutron stars initially formed with periods near 0.001 s that subsequently spin down to their present periods. Accretion-induced white dwarf collapse is then the most plausible genesis for them. 29 refs

  3. X-ray micro-CT and neutron CT as complementary imaging tools for non-destructive 3D imaging of rare silicified fossil plants

    Science.gov (United States)

    Karch, J.; Dudák, J.; Žemlička, J.; Vavřík, D.; Kumpová, I.; Kvaček, J.; Heřmanová, Z.; Šoltés, J.; Viererbl, L.; Morgano, M.; Kaestner, A.; Trtík, P.

    2017-12-01

    Computed tomography provides 3D information of inner structures of investigated objects. The obtained information is, however, strongly dependent on the used radiation type. It is known that as X-rays interact with electron cloud and neutrons with atomic nucleus, the obtained data often provide different contrast of sample structures. In this work we present a set of comparative radiographic and CT measurements of rare fossil plant samples using X-rays and thermal neutrons. The X-ray measurements were performed using large area photon counting detectors Timepix at IEAP CTU in Prague and Perkin Elmer flat-panel detector at Center of Excellence Telč. The neutron CT measurement was carried out at Paul Scherrer Institute using BOA beam-line. Furthermore, neutron radiography of fossil samples, provided by National Museum, were performed using a large-area Timepix detector with a neutron-sensitive converting 6LiF layer at Research Centre Rez, Czech Republic. The obtained results show different capabilities of both imaging approaches. While X-ray micro-CT provides very high resolution and enables visualization of fine cracks or small cavities in the samples neutron imaging provides high contrast of morphological structures of fossil plant samples, where X-ray imaging provides insufficient contrast.

  4. Beryllium window flange for synchrotron radiation X-ray beamline fabricated by hot isostatic press method

    International Nuclear Information System (INIS)

    Asaoka, Seiji; Maezawa, Hideki; Nishida, Kiyotoshi; Sakamoto, Naoki.

    1995-01-01

    The synchrotron radiation experimental facilities in National Laboratory for High Energy Physics are the experimental facilities for joint utilization, that possess the positron storage ring of 2.5 GeV exclusively used for synchrotron radiation. Synchrotron radiation is led through a mainstay beam channel to the laboratory, and in the beam line of X-ray, it is used for experiment through the taking-out window made of beryllium. At this time, the function of the taking-out window is to shut off between the ultrahigh vacuum in the mainstay beam channel and the atmosphere, and to cut the low energy component of synchrotron radiation spectra. The experiment using X-ray is carried out mostly in the atmosphere. The design of the efficient cooling water channel which is compatible with the flange construction is important under the high thermal load of synchrotron radiation. The beryllium window flange for synchrotron radiation X-ray was made by HIP method, and the ultrahigh vacuum test, the high pressure water flow test and the actual machine test were carried out by heat cycle. The properties required for the window material, the requirement of the construction, the new development of HIP method, and the experiments for evaluating the manufactured beryllium window are described. (K.I.)

  5. A standardless method of quantitative ceramic analysis using X-ray powder diffraction

    International Nuclear Information System (INIS)

    Mazumdar, S.

    1999-01-01

    A new procedure using X-ray powder diffraction data for quantitative estimation of the crystalline as well as the amorphous phase in ceramics is described. Classification of the crystalline and amorphous X-ray scattering was achieved by comparison of the slopes at two successive points of the powder pattern at scattering angles at which the crystalline and amorphous phases superimpose. If the second slope exceeds the first by a stipulated value, the intensity is taken as crystalline; otherwise the scattering is considered as amorphous. Crystalline phase analysis is obtained by linear programming techniques using the concept that each observed X-ray diffraction peak has contributions from n component phases, the proportionate analysis of which is required. The method does not require the measurement of calibration data for use as an internal standard, but knowledge of the approximate crystal structure of each phase of interest in the mixture is necessary. The technique is also helpful in qualitative analysis because each suspected phase is characterized by the probability that it will be present when a reflection zone is considered in which the suspected crystalline phase could contribute. The amorphous phases are determined prior to the crystalline ones. The method is applied to ceramic materials and some results are presented. (orig.)

  6. Inhibition of d-xylose isomerase by polyols: atomic details by joint X-ray/neutron crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Kovalevsky, Andrey, E-mail: ayk@lanl.gov [Los Alamos National Laboratory, PO Box 1663, MS M888, Los Alamos, NM 87545 (United States); Hanson, B. Leif [University of Toledo, 2801 West Bancroft Street, Toledo, OH 43606 (United States); Mason, Sax A. [Institut Laue–Langevin, 6 Rue Jules Horowitz, 38042 Grenoble (France); Forsyth, V. Trevor [Institut Laue–Langevin, 6 Rue Jules Horowitz, 38042 Grenoble (France); Keele University, Staffordshire (United Kingdom); Fisher, Zoe [Los Alamos National Laboratory, PO Box 1663, MS M888, Los Alamos, NM 87545 (United States); Mustyakimov, Marat [Los Alamos National Laboratory, PO Box 1663, MS M888, Los Alamos, NM 87545 (United States); Oak Ridge National Laboratory, PO Box 2008, MS 6475, Oak Ridge, TN 37831 (United States); Blakeley, Matthew P. [Institut Laue–Langevin, 6 Rue Jules Horowitz, 38042 Grenoble (France); Keen, David A. [Harwell Science and Innovation Campus, Didcot, Oxon OX11 0QX (United Kingdom); Langan, Paul [Oak Ridge National Laboratory, PO Box 2008, MS 6475, Oak Ridge, TN 37831 (United States); Los Alamos National Laboratory, PO Box 1663, MS M888, Los Alamos, NM 87545 (United States)

    2012-09-01

    A joint X-ray/neutron structure of d-xylose isomerase in complex with the inhibitor sorbitol was determined at room temperature at an acidic pH of 5.9. Protonation of the O5 O atom of the sugar was directly observed in the nuclear density maps. Under acidic conditions sorbitol gains a water-mediated interaction with the enzyme active site, which may explain the increased potency of the inhibitor at low pH. d-Xylose isomerase (XI) converts the aldo-sugars xylose and glucose to their keto analogs xylulose and fructose, but is strongly inhibited by the polyols xylitol and sorbitol, especially at acidic pH. In order to understand the atomic details of polyol binding to the XI active site, a 2.0 Å resolution room-temperature joint X-ray/neutron structure of XI in complex with Ni{sup 2+} cofactors and sorbitol inhibitor at pH 5.9 and a room-temperature X-ray structure of XI containing Mg{sup 2+} ions and xylitol at the physiological pH of 7.7 were obtained. The protonation of oxygen O5 of the inhibitor, which was found to be deprotonated and negatively charged in previous structures of XI complexed with linear glucose and xylulose, was directly observed. The Ni{sup 2+} ions occupying the catalytic metal site (M2) were found at two locations, while Mg{sup 2+} in M2 is very mobile and has a high B factor. Under acidic conditions sorbitol gains a water-mediated interaction that connects its O1 hydroxyl to Asp257. This contact is not found in structures at basic pH. The new interaction that is formed may improve the binding of the inhibitor, providing an explanation for the increased affinity of the polyols for XI at low pH.

  7. Cone Beam X-Ray Luminescence Tomography Imaging Based on KA-FEM Method for Small Animals.

    Science.gov (United States)

    Chen, Dongmei; Meng, Fanzhen; Zhao, Fengjun; Xu, Cao

    2016-01-01

    Cone beam X-ray luminescence tomography can realize fast X-ray luminescence tomography imaging with relatively low scanning time compared with narrow beam X-ray luminescence tomography. However, cone beam X-ray luminescence tomography suffers from an ill-posed reconstruction problem. First, the feasibility of experiments with different penetration and multispectra in small animal has been tested using nanophosphor material. Then, the hybrid reconstruction algorithm with KA-FEM method has been applied in cone beam X-ray luminescence tomography for small animals to overcome the ill-posed reconstruction problem, whose advantage and property have been demonstrated in fluorescence tomography imaging. The in vivo mouse experiment proved the feasibility of the proposed method.

  8. X-ray and neutron scattering study of organic-organic heterolayers for organic electronics and biointerfaces

    International Nuclear Information System (INIS)

    Huth, Martin

    2010-01-01

    The presented work deals with fundamental research to develop an all-organic sensor device capable of detecting changes of the electrical potential, e.g. neural activity, in a biologically relevant environment. In this approach the active area of the sensor is built from organic materials only. The effective interface between the sensor and the cells is an artificial cell membrane decorated with a synthetic binding unit, which has been constructed adopting the methods found in nature. The sensor itself is an organic thin film transistor (OTFT), obtaining its sensitivity from the properties of the organic semiconductor and from having an active layer with a thickness of only 50 nm. The fabricated multilayer systems were characterized with X-ray and neutron diffraction using giant equipment (synchrotron, reactor). A major focus of the presented thesis lies on discovering and manipulating the structure of the involved materials on the molecular scale. At first, an overview on aggregation mechanism and molecular interaction with surfaces depending on the shape of the molecules is given. The experimental part deals with the growth of the organic semiconductor, pentacene (C 22 H 14 ) on various surfaces. By chemically modifying diamond surfaces, controlled pentacene film growth in a standing or lying configuration was achieved. Furthermore, the encapsulation with an alkane, tetratetracontane (TTC, C 44 H 90 ), which has been achieved using vacuum deposition. Applying the correct process parameters, the electronically best suited ''thin film phase'' of pentacene could be conserved. Coating of the pentacene film with a TTC layer was possible in a way that a transducer device showed stable operation in ionic aqueous environment, which is the essential step towards sensor technology. On the other hand we succeeded in constructing a versatile functional coating, providing a surface which cells accept as their ''natural'' environment. On the basis of a supported lipid bilayer

  9. X-ray and neutron scattering study of organic-organic heterolayers for organic electronics and biointerfaces

    Energy Technology Data Exchange (ETDEWEB)

    Huth, Martin

    2010-12-23

    The presented work deals with fundamental research to develop an all-organic sensor device capable of detecting changes of the electrical potential, e.g. neural activity, in a biologically relevant environment. In this approach the active area of the sensor is built from organic materials only. The effective interface between the sensor and the cells is an artificial cell membrane decorated with a synthetic binding unit, which has been constructed adopting the methods found in nature. The sensor itself is an organic thin film transistor (OTFT), obtaining its sensitivity from the properties of the organic semiconductor and from having an active layer with a thickness of only 50 nm. The fabricated multilayer systems were characterized with X-ray and neutron diffraction using giant equipment (synchrotron, reactor). A major focus of the presented thesis lies on discovering and manipulating the structure of the involved materials on the molecular scale. At first, an overview on aggregation mechanism and molecular interaction with surfaces depending on the shape of the molecules is given. The experimental part deals with the growth of the organic semiconductor, pentacene (C{sub 22}H{sub 14}) on various surfaces. By chemically modifying diamond surfaces, controlled pentacene film growth in a standing or lying configuration was achieved. Furthermore, the encapsulation with an alkane, tetratetracontane (TTC, C{sub 44}H{sub 90}), which has been achieved using vacuum deposition. Applying the correct process parameters, the electronically best suited ''thin film phase'' of pentacene could be conserved. Coating of the pentacene film with a TTC layer was possible in a way that a transducer device showed stable operation in ionic aqueous environment, which is the essential step towards sensor technology. On the other hand we succeeded in constructing a versatile functional coating, providing a surface which cells accept as their &apos

  10. X-ray and neutron scattering study of organic-organic heterolayers for organic electronics and biointerfaces

    Energy Technology Data Exchange (ETDEWEB)

    Huth, Martin

    2010-12-23

    The presented work deals with fundamental research to develop an all-organic sensor device capable of detecting changes of the electrical potential, e.g. neural activity, in a biologically relevant environment. In this approach the active area of the sensor is built from organic materials only. The effective interface between the sensor and the cells is an artificial cell membrane decorated with a synthetic binding unit, which has been constructed adopting the methods found in nature. The sensor itself is an organic thin film transistor (OTFT), obtaining its sensitivity from the properties of the organic semiconductor and from having an active layer with a thickness of only 50 nm. The fabricated multilayer systems were characterized with X-ray and neutron diffraction using giant equipment (synchrotron, reactor). A major focus of the presented thesis lies on discovering and manipulating the structure of the involved materials on the molecular scale. At first, an overview on aggregation mechanism and molecular interaction with surfaces depending on the shape of the molecules is given. The experimental part deals with the growth of the organic semiconductor, pentacene (C{sub 22}H{sub 14}) on various surfaces. By chemically modifying diamond surfaces, controlled pentacene film growth in a standing or lying configuration was achieved. Furthermore, the encapsulation with an alkane, tetratetracontane (TTC, C{sub 44}H{sub 90}), which has been achieved using vacuum deposition. Applying the correct process parameters, the electronically best suited ''thin film phase'' of pentacene could be conserved. Coating of the pentacene film with a TTC layer was possible in a way that a transducer device showed stable operation in ionic aqueous environment, which is the essential step towards sensor technology. On the other hand we succeeded in constructing a versatile functional coating, providing a surface which cells accept as their ''natural'' environment. On the basis of a

  11. X-ray beam generator

    International Nuclear Information System (INIS)

    Koller, T.J.; Randmer, J.A.

    1977-01-01

    A method of minimizing the preferential angular absorption of the divergent beam from an X-ray generator is described. The generator consists of an X-ray shielded housing with an X-ray transmissive window symmetrically placed in radial alignment with a focal spot area on a sloped target surface of an X-ray tube in the housing. The X-ray tube may be of the stationary anode type or of the rotating anode type. (U.K.)

  12. Preparing Monodisperse Macromolecular Samples for Successful Biological Small-Angle X-ray and Neutron Scattering Experiments

    Science.gov (United States)

    Jeffries, Cy M.; Graewert, Melissa A.; Blanchet, Clément E.; Langley, David B.; Whitten, Andrew E.; Svergun, Dmitri I

    2017-01-01

    Small-angle X-ray and neutron scattering (SAXS and SANS) are techniques used to extract structural parameters and determine the overall structures and shapes of biological macromolecules, complexes and assemblies in solution. The scattering intensities measured from a sample contain contributions from all atoms within the illuminated sample volume including the solvent and buffer components as well as the macromolecules of interest. In order to obtain structural information, it is essential to prepare an exactly matched solvent blank so that background scattering contributions can be accurately subtracted from the sample scattering to obtain the net scattering from the macromolecules in the sample. In addition, sample heterogeneity caused by contaminants, aggregates, mismatched solvents, radiation damage or other factors can severely influence and complicate data analysis so it is essential that the samples are pure and monodisperse for the duration of the experiment. This Protocol outlines the basic physics of SAXS and SANS and reveals how the underlying conceptual principles of the techniques ultimately ‘translate’ into practical laboratory guidance for the production of samples of sufficiently high quality for scattering experiments. The procedure describes how to prepare and characterize protein and nucleic acid samples for both SAXS and SANS using gel electrophoresis, size exclusion chromatography and light scattering. Also included are procedures specific to X-rays (in-line size exclusion chromatography SAXS) and neutrons, specifically preparing samples for contrast matching/variation experiments and deuterium labeling of proteins. PMID:27711050

  13. Detection of Reflection Features in the Neutron Star Low-mass X-Ray Binary Serpens X-1 with NICER

    Science.gov (United States)

    Ludlam, R. M.; Miller, J. M.; Arzoumanian, Z.; Bult, P. M.; Cackett, E. M.; Chakrabarty, D.; Enoto, T.; Fabian, A. C.; Gendreau, K. C.; Guillot, S.; Homan, J.; Jaisawal, G. K.; Keek, L.; La Marr, B.; Malacaria, C.; Markwardt, C. B.; Steiner, J. F.; Strohmayer, T. E.

    2018-05-01

    We present Neutron Star Interior Composition Explorer (NICER) observations of the neutron star (NS) low-mass X-ray binary Serpens X-1 during the early mission phase in 2017. With the high spectral sensitivity and low-energy X-ray passband of NICER, we are able to detect the Fe L line complex in addition to the signature broad, asymmetric Fe K line. We confirm the presence of these lines by comparing the NICER data to archival observations with XMM-Newton/Reflection Grating Spectrometer (RGS) and NuSTAR. Both features originate close to the innermost stable circular orbit (ISCO). When modeling the lines with the relativistic line model RELLINE, we find that the Fe L blend requires an inner disk radius of {1.4}-0.1+0.2 R ISCO and Fe K is at {1.03}-0.03+0.13 R ISCO (errors quoted at 90%). This corresponds to a position of {17.3}-1.2+2.5 km and {12.7}-0.4+1.6 km for a canonical NS mass ({M}NS}=1.4 {M}ȯ ) and dimensionless spin value of a = 0. Additionally, we employ a new version of the RELXILL model tailored for NSs and determine that these features arise from a dense disk and supersolar Fe abundance.

  14. Comparison of X-ray and neutron small-angle scattering from an Al-Zn alloy

    International Nuclear Information System (INIS)

    Gerold, V.; Epperson, J.E.; Gerstenberg, K.W.

    1978-01-01

    The normalized integrated small-angle scattered intensity for Al-Zn alloys should be independent of whether the measurements are made with X-rays or neutrons. In order to check this, and thus the correction and standardization processes, the small-angle scattering from an Al-5.05 at.% Zn alloy containing GP zones was measured with these two types of radiation. The data were corrected and converted to absolute units with reference to the commonly accepted secondary standards: vanadium for the neutron data and polyethylene (Lupolen) for the X-ray data. The results are shown to differ by, at best, 6% if reasonable values for the change in atomic volume with alloy composition are taken into account. These findings are compared with those available from the literature, and the consistency is found to be somewhat lacking. Additional careful work is clearly needed to determine if the difficulty is traceable to the data correction or to the conversion to absolute units. (Auth.)

  15. Interfacial mixing in as-deposited Si/Ni/Si layers analyzed by x-ray and polarized neutron reflectometry

    International Nuclear Information System (INIS)

    Bhattacharya, Debarati; Basu, Saibal; Singh, Surendra; Roy, Sumalay; Dev, Bhupendra Nath

    2012-01-01

    Highlights: ► Room temperature diffusion in Si/Ni/Si trilayer detected through complementary x-ray and polarized neutron reflectometry. ► Analyses of XPNR data generated the construction of the layered structure in terms of physical parameters along with alloy layers created by diffusion. ► Scattering length density information from XPNR provided quantitative assessment of the stoichiometry of alloys formed at the Si/Ni and Ni/Si interfaces. - Abstract: Interdiffusion occurring across the interfaces in a Si/Ni/Si layered system during deposition at room temperature was probed using x-ray reflectivity (XRR) and polarized neutron reflectivity (PNR). Exploiting the complementarity of these techniques, both structural and magnetic characterization with nanometer depth resolution could be achieved. Suitable model fitting of the reflectivity profiles identified the formation of Ni–Si mixed alloy layers at the Si/Ni and Ni/Si interfaces. The physical parameters of the layered structure, including quantitative assessment of the stoichiometry of interfacial alloys, were obtained from the analyses of XRR and PNR patterns. In addition, PNR provided magnetic moment density profile as a function of depth in the stratified medium.

  16. Interfacial mixing in as-deposited Si/Ni/Si layers analyzed by x-ray and polarized neutron reflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, Debarati, E-mail: debarati@barc.gov.in [Solid State Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Basu, Saibal; Singh, Surendra [Solid State Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Roy, Sumalay; Dev, Bhupendra Nath [Department of Materials Science, Indian Association for the Cultivation of Science, 2A and 2B Raja S.C. Mullick Road, Jadavpur, Kolkata 700032 (India)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer Room temperature diffusion in Si/Ni/Si trilayer detected through complementary x-ray and polarized neutron reflectometry. Black-Right-Pointing-Pointer Analyses of XPNR data generated the construction of the layered structure in terms of physical parameters along with alloy layers created by diffusion. Black-Right-Pointing-Pointer Scattering length density information from XPNR provided quantitative assessment of the stoichiometry of alloys formed at the Si/Ni and Ni/Si interfaces. - Abstract: Interdiffusion occurring across the interfaces in a Si/Ni/Si layered system during deposition at room temperature was probed using x-ray reflectivity (XRR) and polarized neutron reflectivity (PNR). Exploiting the complementarity of these techniques, both structural and magnetic characterization with nanometer depth resolution could be achieved. Suitable model fitting of the reflectivity profiles identified the formation of Ni-Si mixed alloy layers at the Si/Ni and Ni/Si interfaces. The physical parameters of the layered structure, including quantitative assessment of the stoichiometry of interfacial alloys, were obtained from the analyses of XRR and PNR patterns. In addition, PNR provided magnetic moment density profile as a function of depth in the stratified medium.

  17. Quantitative firing transformations of a triaxial ceramic by X-ray diffraction methods

    International Nuclear Information System (INIS)

    Conconi, M.S.; Gauna, M.R.; Serra, M.F.; Suarez, G.; Aglietti, E.F.; Rendtorff, N.M.

    2014-01-01

    The firing transformations of traditional (clay based) ceramics are of technological and archaeological interest, and are usually reported qualitatively or semi quantitatively. These kinds of systems present an important complexity, especially for X-ray diffraction techniques, due to the presence of fully crystalline, low crystalline and amorphous phases. In this article we present the results of a qualitative and quantitative X-ray diffraction Rietveld analysis of the fully crystalline (kaolinite, quartz, cristobalite, feldspars and/or mullite), the low crystalline (metakaolinite and/or spinel type pre-mullite) and glassy phases evolution of a triaxial (clay-quartz-feldspar) ceramic fired in a wide temperature range between 900 and 1300 deg C. The employed methodology to determine low crystalline and glassy phase abundances is based in a combination of the internal standard method and the use of a nanocrystalline model where the long-range order is lost, respectively. A preliminary sintering characterization was carried out by contraction, density and porosity evolution with the firing temperature. Simultaneous thermo-gravimetric and differential thermal analysis was carried out to elucidate the actual temperature at which the chemical changes occur. Finally, the quantitative analysis based on the Rietveld refinement of the X-ray diffraction patterns was performed. The kaolinite decomposition into metakaolinite was determined quantitatively; the intermediate (980 deg C) spinel type alumino-silicate formation was also quantified; the incongruent fusion of the potash feldspar was observed and quantified together with the final mullitization and the amorphous (glassy) phase formation.The methodology used to analyze the X-ray diffraction patterns proved to be suitable to evaluate quantitatively the thermal transformations that occur in a complex system like the triaxial ceramics. The evaluated phases can be easily correlated with the processing variables and materials

  18. Quantitative firing transformations of a triaxial ceramic by X-ray diffraction methods

    Energy Technology Data Exchange (ETDEWEB)

    Conconi, M.S.; Gauna, M.R.; Serra, M.F. [Centro de Tecnologia de Recursos Minerales y Ceramica (CETMIC), Buenos Aires (Argentina); Suarez, G.; Aglietti, E.F.; Rendtorff, N.M., E-mail: rendtorff@cetmic.unlp.edu.ar [Universidad Nacional de La Plata (UNLP), Buenos Aires (Argentina). Fac. de Ciencias Exactas. Dept. de Quimica

    2014-10-15

    The firing transformations of traditional (clay based) ceramics are of technological and archaeological interest, and are usually reported qualitatively or semi quantitatively. These kinds of systems present an important complexity, especially for X-ray diffraction techniques, due to the presence of fully crystalline, low crystalline and amorphous phases. In this article we present the results of a qualitative and quantitative X-ray diffraction Rietveld analysis of the fully crystalline (kaolinite, quartz, cristobalite, feldspars and/or mullite), the low crystalline (metakaolinite and/or spinel type pre-mullite) and glassy phases evolution of a triaxial (clay-quartz-feldspar) ceramic fired in a wide temperature range between 900 and 1300 deg C. The employed methodology to determine low crystalline and glassy phase abundances is based in a combination of the internal standard method and the use of a nanocrystalline model where the long-range order is lost, respectively. A preliminary sintering characterization was carried out by contraction, density and porosity evolution with the firing temperature. Simultaneous thermo-gravimetric and differential thermal analysis was carried out to elucidate the actual temperature at which the chemical changes occur. Finally, the quantitative analysis based on the Rietveld refinement of the X-ray diffraction patterns was performed. The kaolinite decomposition into metakaolinite was determined quantitatively; the intermediate (980 deg C) spinel type alumino-silicate formation was also quantified; the incongruent fusion of the potash feldspar was observed and quantified together with the final mullitization and the amorphous (glassy) phase formation.The methodology used to analyze the X-ray diffraction patterns proved to be suitable to evaluate quantitatively the thermal transformations that occur in a complex system like the triaxial ceramics. The evaluated phases can be easily correlated with the processing variables and materials

  19. Quantitative firing transformations of a triaxial ceramic by X-ray diffraction methods

    Directory of Open Access Journals (Sweden)

    M. S. Conconi

    2014-12-01

    Full Text Available The firing transformations of traditional (clay based ceramics are of technological and archeological interest, and are usually reported qualitatively or semiquantitatively. These kinds of systems present an important complexity, especially for X-ray diffraction techniques, due to the presence of fully crystalline, low crystalline and amorphous phases. In this article we present the results of a qualitative and quantitative X-ray diffraction Rietveld analysis of the fully crystalline (kaolinite, quartz, cristobalite, feldspars and/or mullite, the low crystalline (metakaolinite and/or spinel type pre-mullite and glassy phases evolution of a triaxial (clay-quartz-feldspar ceramic fired in a wide temperature range between 900 and 1300 ºC. The employed methodology to determine low crystalline and glassy phase abundances is based in a combination of the internal standard method and the use of a nanocrystalline model where the long-range order is lost, respectively. A preliminary sintering characterization was carried out by contraction, density and porosity evolution with the firing temperature. Simultaneous thermo-gravimetric and differential thermal analysis was carried out to elucidate the actual temperature at which the chemical changes occur. Finally, the quantitative analysis based on the Rietveld refinement of the X-ray diffraction patterns was performed. The kaolinite decomposition into metakaolinite was determined quantitatively; the intermediate (980 ºC spinel type alumino-silicate formation was also quantified; the incongruent fusion of the potash feldspar was observed and quantified together with the final mullitization and the amorphous (glassy phase formation.The methodology used to analyze the X-ray diffraction patterns proved to be suitable to evaluate quantitatively the thermal transformations that occur in a complex system like the triaxial ceramics. The evaluated phases can be easily correlated with the processing variables and

  20. Neutron and X-ray study of stoichiometric and doped LiNbO3:Zn0.08

    International Nuclear Information System (INIS)

    Sulyanov, S.; Maximov, B.; Volk, T.; Boysen, H.; Schneider, J.; Rubinina, N.; Hansen, Th.

    2002-01-01

    LiNbO 3 (LN) crystals possess useful optical properties, which are strongly dependent on both the crystal stoichiometry and the content of dopants such as Mg 2+ , Zn 2+ , In 3+ , and Sc 3+ . Such elements drastically reduce photorefraction at a sufficiently high threshold concentration, which for Zn is in the range of 7-8 at. % and was supposed to be connected with the change of dopant-atom localisation in the lattice. We report the results of a single-crystal neutron study of stoichiometric, congruent, and doped (with 8.2 at. % Zn) LiNbO 3 at T=78 K and 298 K and also a multi-pattern powder neutron and X-ray Rietveld refinement of the doped material. Zn ions occupy both Li and Nb sites and there is no residual Nb on Li sites. LN single crystals are very perfect, and extinction problems are discussed. (orig.)

  1. Repair of potentially lethal radiation damage: comparison of neutron and x-ray RBE and implications for radiation therapy

    International Nuclear Information System (INIS)

    Hall, E.J.; Kraljevic, U.

    1976-01-01

    Experiments with Chinese hamster cells have shown that neutron irradiation does not result in repair of potentially lethal damage (PLD), i.e., that which can be influenced by changes in environmental conditions following irradiation. Since PLD is presumed to be repaired in tumors but not in normal tissues, this absence of differential sparing of tumor cells relative to normal tissues--a feature characteristic of irradiation with x rays--represents an advantage of neutrons in addition to their reduced oxygen effect. At a given dose, the difference in relative biological effectiveness (RBE) between tumors and normal tissues corresponds to a 5 percent increase in tumor dose with no concomitant increase in dose to normal tissues, which could be significant in cancer therapy

  2. X-ray magnetic circular dichroism and small angle neutron scattering studies of thiol capped gold nanoparticles

    International Nuclear Information System (INIS)

    de la Venta, J.; Bouzas, V.; Pucci, A.; Laguna-Marco, M.A.; Haskel, D.; te Velthuis, S.G.E; Hoffmann, A.; Lal, J.; Bleuel, M.; Ruggeri, G.; de Julian Fernandez, C.; Garcia, M.A.

    2009-01-01

    X-ray magnetic circular dichroism (XMCD) and Small Angle Neutron Scattering (SANS) measurements were performed on thiol capped Au nanoparticles (NPs) embedded into polyethylene. An XMCD signal of 0.8 · 10 -4 was found at the Au L 3 edge of thiol capped Au NPs embedded in a polyethylene matrix for which Superconducting Quantum Interference Device (SQUID) magnetometry yielded a saturation magnetization, M s , of 0.06 emu/g Au . SANS measurements showed that the 3.2 nm average-diameter nanoparticles are 28% polydispersed, but no detectable SANS magnetic signal was found with the resolution and sensitivity accessible with the neutron experiment. A comparison with previous experiments carried out on Au NPs and multilayers, yield to different values between XMCD signals and magnetization measured by SQUID magnetometer. We discuss the origin of those differences

  3. X-ray magnetic circular dichroism and small angle neutron scattering studies of thiol capped gold nanoparticles.

    Energy Technology Data Exchange (ETDEWEB)

    de la Venta, J.; Bouzas, V.; Pucci, A.; Laguna-Marco, M. A.; Haskel, D.; te Velthuis, S. G. E; Hoffmann, A.; Lal, J.; Bleuel, M.; Ruggeri, G.; de Julian Fernandez, C.; Garcia, M. A.; Univ.Complutense de Madrid; Inst. de Magnetismo Aplicado; Univ. of Pisa; Lab. di Magnetismo Molecolare

    2009-01-01

    X-ray magnetic circular dichroism (XMCD) and Small Angle Neutron Scattering (SANS) measurements were performed on thiol capped Au nanoparticles (NPs) embedded into polyethylene. An XMCD signal of 0.8 {center_dot} 10{sup -4} was found at the Au L{sub 3} edge of thiol capped Au NPs embedded in a polyethylene matrix for which Superconducting Quantum Interference Device (SQUID) magnetometry yielded a saturation magnetization, M{sub s}, of 0.06 emu/g{sub Au}. SANS measurements showed that the 3.2 nm average-diameter nanoparticles are 28% polydispersed, but no detectable SANS magnetic signal was found with the resolution and sensitivity accessible with the neutron experiment. A comparison with previous experiments carried out on Au NPs and multilayers, yield to different values between XMCD signals and magnetization measured by SQUID magnetometer. We discuss the origin of those differences.

  4. X-ray magnetic circular dichroism and small angle neutron scattering study of thiol capped gold nanoparticles.

    Energy Technology Data Exchange (ETDEWEB)

    de la Venta, J.; Bouzas, V.; Pucci, A.; Laguna-Marco, M. A.; Haskel, D.; Pinel, E. F.; te Velthuis, S. G. E.; Hoffmann, A.; Lal, J.; Bleuel, M.; Ruggeri, G.; de Julian, C.; Garcia, M. A.; Univ. Complutense de Madrid; Inst. de Magnetismo Aplicado UCM; Univ. Pisa; Univ. di Padova

    2009-11-01

    X-ray magnetic circular dichroism (XMCD) and Small Angle Neutron Scattering (SANS) measurements were performed on thiol capped Au nanoparticles (NPs) embedded into polyethylene. An XMCD signal of 0.8 {center_dot} 10{sup -4} was found at the Au L{sub 3} edge of thiol capped Au NPs embedded in a polyethylene matrix for which Superconducting Quantum Interference Device (SQUID) magnetometry yielded a saturation magnetization, M{sub s}, of 0.06 emu/g{sub Au}. SANS measurements showed that the 3.2 nm average-diameter nanoparticles are 28% polydispersed, but no detectable SANS magnetic signal was found with the resolution and sensitivity accessible with the neutron experiment. A comparison with previous experiments carried out on Au NPs and multilayers, yield to different values between XMCD signals and magnetization measured by SQUID magnetometer. We discuss the origin of those differences.

  5. Experimental validation of a multi-energy x-ray adapted scatter separation method

    Science.gov (United States)

    Sossin, A.; Rebuffel, V.; Tabary, J.; Létang, J. M.; Freud, N.; Verger, L.

    2016-12-01

    Both in radiography and computed tomography (CT), recently emerged energy-resolved x-ray photon counting detectors enable the identification and quantification of individual materials comprising the inspected object. However, the approaches used for these operations require highly accurate x-ray images. The accuracy of the images is severely compromised by the presence of scattered radiation, which leads to a loss of spatial contrast and, more importantly, a bias in radiographic material imaging and artefacts in CT. The aim of the present study was to experimentally evaluate a recently introduced partial attenuation spectral scatter separation approach (PASSSA) adapted for multi-energy imaging. For this purpose, a prototype x-ray system was used. Several radiographic acquisitions of an anthropomorphic thorax phantom were performed. Reference primary images were obtained via the beam-stop (BS) approach. The attenuation images acquired from PASSSA-corrected data showed a substantial increase in local contrast and internal structure contour visibility when compared to uncorrected images. A substantial reduction of scatter induced bias was also achieved. Quantitatively, the developed method proved to be in relatively good agreement with the BS data. The application of the proposed scatter correction technique lowered the initial normalized root-mean-square error (NRMSE) of 45% between the uncorrected total and the reference primary spectral images by a factor of 9, thus reducing it to around 5%.

  6. Spectrum unfolding in X-ray spectrometry using the maximum entropy method

    International Nuclear Information System (INIS)

    Fernandez, Jorge E.; Scot, Viviana; Di Giulio, Eugenio

    2014-01-01

    The solution of the unfolding problem is an ever-present issue in X-ray spectrometry. The maximum entropy technique solves this problem by taking advantage of some known a priori physical information and by ensuring an outcome with only positive values. This method is implemented in MAXED (MAXimum Entropy Deconvolution), a software code contained in the package UMG (Unfolding with MAXED and GRAVEL) developed at PTB and distributed by NEA Data Bank. This package contains also the code GRAVEL (used to estimate the precision of the solution). This article introduces the new code UMESTRAT (Unfolding Maximum Entropy STRATegy) which applies a semi-automatic strategy to solve the unfolding problem by using a suitable combination of MAXED and GRAVEL for applications in X-ray spectrometry. Some examples of the use of UMESTRAT are shown, demonstrating its capability to remove detector artifacts from the measured spectrum consistently with the model used for the detector response function (DRF). - Highlights: ► A new strategy to solve the unfolding problem in X-ray spectrometry is presented. ► The presented strategy uses a suitable combination of the codes MAXED and GRAVEL. ► The applied strategy provides additional information on the Detector Response Function. ► The code UMESTRAT is developed to apply this new strategy in a semi-automatic mode

  7. A method to unfold the efficiency of gaseous detectors exposed to broad X-ray spectra

    International Nuclear Information System (INIS)

    Almeida, Gevaldo L. de; Souza, Maria Ines S. de; Lopes, Ricardo T.

    2000-01-01

    A method to obtain the efficiency of a gaseous detector exposed to broad energy X-ray spectra was developed. It consists in the de-convolution of the integrated detector response using the shapes of those spectra as a tool to unfold the aimed detector efficiency curve. For this purpose, the spectra emitted by a X-ray tube under several anode voltages, were properly characterized through measurements with a NaI(Tl) spectrometer. A Lorentz function was then fitted to each of the spectra, and their parameters expressed as a function of the anode voltage, by using polynomial and gaussian fittings. The integral of the product of each Lorentz function, by another unknown Lorentz function, expressing the detector efficiency curve, represents the response of the detector for each anode tension, e.g., each X-ray spectrum. The symbolical integration of that product, produces a general function containing the unknown parameters of the unknown efficiency curve. A non-linear fitting of this general function, to the detector response points, as experimentally obtained, generates the aimed parameters for the efficiency curve. The final detector efficiency curve is obtained after normalization procedures. (author)

  8. Introducing a standard method for experimental determination of the solvent response in laser pump, x-ray probe time-resolved wide-angle x-ray scattering experiments on systems in solution

    DEFF Research Database (Denmark)

    Kjær, Kasper Skov; Brandt van Driel, Tim; Kehres, Jan

    2013-01-01

    In time-resolved laser pump, X-ray probe wide-angle X-ray scattering experiments on systems in solution the structural response of the system is accompanied by a solvent response. The solvent response is caused by reorganization of the bulk solvent following the laser pump event, and in order...... response-the solvent term-experimentally when applying laser pump, X-ray probe time-resolved wide-angle X-ray scattering. The solvent term describes difference scattering arising from the structural response of the solvent to changes in the hydrodynamic parameters: pressure, temperature and density. We...... is demonstrated to exhibit first order behaviour with respect to the amount of energy deposited in the solution. We introduce a standardized method for recording solvent responses in laser pump, X-ray probe time-resolved X-ray wide-angle scattering experiments by using dye mediated solvent heating. Furthermore...

  9. Radioactivation and X-ray fluorescence methods of determination of some elements in atmospheric air and waters

    International Nuclear Information System (INIS)

    Kulmatov, R.A.; Kist, A.A.; Karimov, I.I.; Pulatov, D.D.; Kamil'dzhanov, A.Kh.

    1981-01-01

    Possibilities of instrumental radioactivation and X-ray fluorescence method of determining certain elements in aerosols and waters in the region of metallurgic production location and around it are considered. For conducting instrumental radioactivation analysis the samples have been irradiated on filter during 20h in the thermal neutron flux f=10 13 neutr/cm 2 xs of nuclear reactor-WWR-SM INP ASUzSSR. Measurement of induced activity has been conducted after 7 and 15-day cooling by means of Ge(Li) detectors. Averaged results of instrumental radioactivation and X-ray fluorescence analysis of element (Cu, Zn, Fe, Pb) composifion of some samples are presented. Content of such elements as copper, zinc, lead in the industrial region several times exceeds usual background content that is caused by industrial releases. Toxic effect, rate of aerosol release from atmosphere and radius of harmful effect of industrial enterprises on environment much depends on dispersion. A set of filter materials differing from one another by pore diameter have been used for conducting dispersion analysis of aerosals [ru

  10. Determination of the absolute configuration of (+)-neopentyl-1-d alcohol by neutron and x-ray diffraction analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, H.S.H.; Stevens, R.C.; Bau, R. (Univ. of Southern California, Los Angeles, CA (United States)); Mosher, H.S. (Stanford Univ., CA (United States)); Koetzle, T.F. (Brookhaven National Lab., Upton, NY (United States))

    1994-12-20

    The absolute configuration of (+)-neopentyl-1-d alcohol, prepared by the reduction of 2,2-dimethylpropanol-1-d by actively fermenting yeast, has been determined to be S by neutron diffraction. The neutron study was carried out on the phthalate half ester of neopentyl-1-d alcohol, crystallized as its strychnine salt. The absolute configuration of the (-)-strychninium cation was first determined by an x-ray anomalous dispersion study of its iodide salt. The chiral skeleton of strychnine then served as a reference from which the absolute configuration of the -O-CHD-C(CH[sub 3])[sub 3] group of neopentyl phthalate was determined. Difference Fourier maps calculated from the neutron data showed unambiguously that the -O-CHD-C(CH[sub 3])[sub 3] groups of both independent molecules in the unit cell had the S configuration. This work proves conclusively that the yeast system reduces aldehydes by delivering hydrogen to the re face of the carbonyl group. Crystallographic details: (-)-strychninium (+)-neopentyl-1-d phthalate, space group P2[sub 1] (monoclinic), a = 18.564(6) [angstrom], b = 7.713(2) [angstrom], c = 23.361(8) [angstrom], [beta] = 94.18(4)[degrees], V = 3336.0(5) [angstrom][sup 3], Z = 2 (T = 100 K). Final agreement factors are R(F) = 0.073 for 2768 reflections collected at room temperature (x-ray analysis) and R(F) = 0.144 for 960 reflections collected at 100 K (neutron analysis). 49 refs., 7 figs., 2 tabs.

  11. Spectral-Timing Analysis of Kilohetrz Quasi-Periodic Osciallations in Neutron Star Low-Mass X-ray Binaries

    Science.gov (United States)

    Cackett, Edward; Troyer, Jon; Peille, Philippe; Barret, Didier

    2018-01-01

    Kilohertz quasi-periodic oscillations or kHz QPOs are intensity variations that occur in the X-ray band observed in neutron star low-mass X-ray binary (LMXB) systems. In such systems, matter is transferred from a secondary low-mass star to a neutron star via the process of accretion. kHz QPOs occur on the timescale of the inner accretion flow and may carry signatures of the physics of strong gravity (c2 ~ GM/R) and possibly clues to constraining the neutron star equation of state (EOS). Both the timing behavior of kHz QPOs and the time-averaged spectra of these systems have been studied extensively. No model derived from these techniques has been able to illuminate the origin of kHz QPOs. Spectral-timing is an analysis technique that can be used to derive information about the nature of physical processes occurring within the accretion flow on the timescale of the kHz QPO. To date, kHz QPOs of (4) neutron star LMXB systems have been studied with spectral-timing techniques. We present a comprehensive study of spectral-timing products of kHz QPOs from systems where data is available in the RXTE archive to demonstrate the promise of this technique to gain insights regarding the origin of kHz QPOs. Using data averaged over the entire RXTE archive, we show correlated time-lags as a function of QPO frequency and energy, as well as energy-dependent covariance spectra for the various LMXB systems where spectral-timing analysis is possible. We find similar trends in all average spectral-timing products for the objects studied. This suggests a common origin of kHz QPOs.

  12. X-ray micro-CT and neutron CT as complementary imaging tools for non-destructive 3D imaging of rare silicified fossil plants

    Czech Academy of Sciences Publication Activity Database

    Karch, J.; Dudák, J.; Žemlička, J.; Vavřík, Daniel; Kumpová, Ivana; Kvaček, J.; Heřmanová, Z.; Šoltés, J.; Viererbl, L.; Morgano, M.; Kaestner, A.; Trtík, P.

    2017-01-01

    Roč. 12, December (2017), č. článku C12004. ISSN 1748-0221 R&D Projects: GA MŠk(CZ) LO1219 Keywords : inspection with neutrons * X-ray detectors * X ray radiography Subject RIV: DB - Geology ; Mineralogy OBOR OECD: Paleontology Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/12/12/C12004/pdf

  13. Final Report for X-ray Diffraction Sample Preparation Method Development

    Energy Technology Data Exchange (ETDEWEB)

    Ely, T. M. [Hanford Site (HNF), Richland, WA (United States); Meznarich, H. K. [Hanford Site (HNF), Richland, WA (United States); Valero, T. [Hanford Site (HNF), Richland, WA (United States)

    2018-01-30

    WRPS-1500790, “X-ray Diffraction Saltcake Sample Preparation Method Development Plan/Procedure,” was originally prepared with the intent of improving the specimen preparation methodology used to generate saltcake specimens suitable for XRD-based solid phase characterization. At the time that this test plan document was originally developed, packed powder in cavity supports with collodion binder was the established XRD specimen preparation method. An alternate specimen preparation method less vulnerable, if not completely invulnerable to preferred orientation effects, was desired as a replacement for the method.

  14. Structure of 3 at.% and 9 at.% Si-doped HfO{sub 2} from combined refinement of X-ray and neutron diffraction patterns

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Lili [Department of Materials Science and Engineering, North Carolina State University, NC 27695 (United States); School of Information Science and Technology, Northwest University, Xi' an 710127 (China); Hou, Dong; Usher, Tedi-Marie; Iamsasri, Thanakorn; Fancher, Chris M.; Forrester, Jennifer S. [Department of Materials Science and Engineering, North Carolina State University, NC 27695 (United States); Nishida, Toshikazu [Department of Electrical and Computer Engineering, University of Florida, FL 32611 (United States); Moghaddam, Saeed [Department of Mechanical and Aerospace Engineering, University of Florida, FL 32611 (United States); Jones, Jacob L., E-mail: jacobjones@ncsu.edu [Department of Materials Science and Engineering, North Carolina State University, NC 27695 (United States)

    2015-10-15

    The crystal structure of 3 at.% and 9 at.% Si-doped HfO{sub 2} powder was determined through refinements using X-ray and neutron diffraction patterns. The lattice parameters, atomic positions, dopant occupancy, and the second phase fraction were determined with high precision using a combined full pattern fitting via the Rietveld method. The results show that both 3 at.% and 9 at.% Si-doped HfO{sub 2} powder exhibit the monoclinic crystal structure with P 1 2{sub 1}/c 1 space group. Through the combined refinement, the crystal structure parameters, especially for the positions and occupancies of the lighter atoms, were more precisely determined compared to independent X-ray diffraction refinement. Although the ionic radius of Si{sup 4+} is smaller than Hf{sup 4+}, with increasing Si occupancy, the unit cell volume slightly increases; possible mechanisms for this effect are discussed. Moreover, the refined results provide evidence of the existence of a non-equilibrium phase of Hf{sub x}Si{sub 1−x}O{sub 2}. The second phase (SiO{sub 2}) fraction is determined as 0.17 at.% for 3 at.% Si-doped HfO{sub 2} powders and 1.7 at.% for 9 at.% Si-doped HfO{sub 2} powders. - Highlights: • X-ray and neutron diffraction patterns were used to determine crystal structure. • Results from independent refinements and a combined refinement were compared. • Highly precise structural parameters were obtained by the combined refinement. • Structural data of 3 at.% and 9 at.% Si-doped HfO{sub 2} are provided. • The unit cell volume slightly increases with Si concentration from 3 to 9 at.%.

  15. Improved image alignment method in application to X-ray images and biological images.

    Science.gov (United States)

    Wang, Ching-Wei; Chen, Hsiang-Chou

    2013-08-01

    Alignment of medical images is a vital component of a large number of applications throughout the clinical track of events; not only within clinical diagnostic settings, but prominently so in the area of planning, consummation and evaluation of surgical and radiotherapeutical procedures. However, image registration of medical images is challenging because of variations on data appearance, imaging artifacts and complex data deformation problems. Hence, the aim of this study is to develop a robust image alignment method for medical images. An improved image registration method is proposed, and the method is evaluated with two types of medical data, including biological microscopic tissue images and dental X-ray images and compared with five state-of-the-art image registration techniques. The experimental results show that the presented method consistently performs well on both types of medical images, achieving 88.44 and 88.93% averaged registration accuracies for biological tissue images and X-ray images, respectively, and outperforms the benchmark methods. Based on the Tukey's honestly significant difference test and Fisher's least square difference test tests, the presented method performs significantly better than all existing methods (P ≤ 0.001) for tissue image alignment, and for the X-ray image registration, the proposed method performs significantly better than the two benchmark b-spline approaches (P < 0.001). The software implementation of the presented method and the data used in this study are made publicly available for scientific communities to use (http://www-o.ntust.edu.tw/∼cweiwang/ImprovedImageRegistration/). cweiwang@mail.ntust.edu.tw.

  16. A simple method for controlling the line width of SASE X-ray FELs

    International Nuclear Information System (INIS)

    Geloni, Gianluca; Kocharyan, Vitali; Saldin, Evgeni

    2010-04-01

    This paper describes a novel single-bunch self-seeding scheme for generating highly monochromatic X-rays from a baseline XFEL undulator. A self-seeded XFEL consists of two undulators with an X-ray monochromator located between them. Previous self-seeding schemes made use of a four-crystal fixed-exit monochromator in Bragg geometry. In such monochromator the X-ray pulse acquires a cm-long path delay, which must be compensated. For a single-bunch self-seeding scheme this requires a long electron beam bypass, implying modifications of the baseline undulator configuration. To avoid this problem, a double bunch self-seeding scheme based on a special photoinjector setup was recently proposed. At variance, here we propose a new time-domain method of monochromatization exploiting a single crystal in the transmission direction, thus avoiding the problem of extra-path delay for the X-ray pulse. The method can be realized using a temporal windowing technique, requiring a magnetic delay for the electron bunch only. When the incident X-ray beam satisfies the Bragg diffraction condition, multiple scattering takes place and the transmittance spectrum in the crystal exhibits an absorption resonance with a narrow linewidth. Then, the temporal waveform of the transmitted radiation pulse is characterized by a long monochromatic wake. The radiation power within this wake is much larger than the shot noise power. At the entrance of the second undulator, the monochromatic wake of the radiation pulse is combined with the delayed electron bunch, and amplified up to saturation level. The proposed setup is extremely simple and composed of as few as two simple elements. These are the crystal and the short magnetic chicane, which accomplishes three tasks by itself. It creates an offset for crystal installation, it removes the electron micro-bunching produced in the first undulator, and it acts as a delay line for temporal windowing. Using a single crystal installed within a short magnetic

  17. X-Ray and Neutron Diffraction Measurements of Dislocation Density and Subgrain Size in a Friction-Stir-Welded Aluminum Alloy

    International Nuclear Information System (INIS)

    Woo, Wan Chuck; Ungar, Tomas; Feng, Zhili; Kenik, Edward A.; Clausen, B.

    2009-01-01

    The dislocation density and subgrain size were determined in the base material and friction-stir welds of 6061-T6 aluminum alloy. High-resolution X-ray diffraction measurement was performed in the base material. The result of the line profile analysis of the X-ray diffraction peak shows that the dislocation density is about 4.5 x 10 14 m -2 and the subgrain size is about 200 nm. Meanwhile, neutron diffraction measurements have been performed to observe the diffraction peaks during friction-stir welding (FSW). The deep penetration capability of the neutron enables us to measure the peaks from the midplane of the Al plate underneath the tool shoulder of the friction-stir welds. The peak broadening analysis result using the Williamson-Hall method shows the dislocation density of about 3.2 x 10 15 m -2 and subgrain size of about 160 nm. The significant increase of the dislocation density is likely due to the severe plastic deformation during FSW. This study provides an insight into understanding the transient behavior of the microstructure under severe thermomechanical deformation

  18. Determination of sulfur and chlorine in fodder by X-ray fluorescence spectral analysis and comparison with other analytical methods

    Science.gov (United States)

    Nečemer, Marijan; Kump, Peter; Rajčevič, Marija; Jačimović, Radojko; Budič, Bojan; Ponikvar, Maja

    2003-07-01

    Sulfur and chlorine are essential elements in the metabolic processes of ruminants, and correct planning strategy of ruminant nutrition should provide a sufficient content of S and Cl in the animal's body. S and Cl can be found in various types of animal fodder in the form of organic compounds and minerals. In this work, the Cl and S content in forage was determined by X-ray fluorescence spectrometry (XRF), and its performance was then compared in parallel analyses by instrumental neutron activation analysis (INAA), inductively coupled plasma atomic emission spectrometry (ICP-AES) and potentiometric methods. The results were compared and critically evaluated in order to assess the performance and capability of the XRF technique in analysis of animal fodder.

  19. Determination of sulfur and chlorine in fodder by X-ray fluorescence spectral analysis and comparison with other analytical methods

    Energy Technology Data Exchange (ETDEWEB)

    Necemer, Marijan; Kump, Peter; Rajcevic, Marija; Jacimovic, Radojko; Budic, Bojan; Ponikvar, Maja

    2003-07-18

    Sulfur and chlorine are essential elements in the metabolic processes of ruminants, and correct planning strategy of ruminant nutrition should provide a sufficient content of S and Cl in the animal's body. S and Cl can be found in various types of animal fodder in the form of organic compounds and minerals. In this work, the Cl and S content in forage was determined by X-ray fluorescence spectrometry (XRF), and its performance was then compared in parallel analyses by instrumental neutron activation analysis (INAA), inductively coupled plasma atomic emission spectrometry (ICP-AES) and potentiometric methods. The results were compared and critically evaluated in order to assess the performance and capability of the XRF technique in analysis of animal fodder.

  20. Selection of polychlorinated plastics in plastic waste by X-ray fluorescence method

    International Nuclear Information System (INIS)

    Kumasaki, H.; Shinozaki, Y.

    1979-01-01

    The X-ray fluorescence method using a small source of 55 Fe was examined and found to be applicable for the selection of polychlorinated plastics from plastic waste in model areas in Tokyo designated for investigating their content in the waste. The weight ratios of soft and hard polychlorinated plastics to the total plastic waste estimated by this method were found to be 15.6% and 0.29% respectively. These values agree well with the results obtained with the Beilstein method. (author)

  1. Trace rare earth analysis by neutron activation and γ-ray/x-ray spectrometry

    International Nuclear Information System (INIS)

    Laul, J.C.; Nielson, K.K.; Wogman, N.A.

    1977-01-01

    A rare earth group separation scheme followed by photon energy analysis using Ge(Li) and intrinsic Ge detectors enhances significantly the detection of individual rare earth elements (REE) at or below the ppb level. Based on the x-ray and selected γ-ray energies, Ge(Li) γ-ray counting is favorable for 140 La, 141 Ce, 142 Pr, 153 Sm, 171 Er, and 177 Lu, whereas intrinsic Ge γ-ray counting is favorable for 143 Ce, 147 Nd, 160 Tb, and 166 Ho, and intrinsic Ge x-ray counting is favorable for 152 Eu and 175 Yb. Gamma-ray counting of 153 Gd and 170 Tm is equally sensitive with Ge(Li) or intrinsic Ge detectors. Precise measurements of the REE were made in the USGS geological samples BCR-1, W-1, AGV-1, G2, GSP-1 and PCC-1, the IAEA Soil-5, and the NBS orchard leaf and bovine liver standards. Their chondritic normalized REE patterns behave as a smooth function of the REE ionic radii. Interestingly, the REE patterns observed in orchard leaf and other plants are identical to the REE pattern in bovine liver. This comparison leads us to suggest that the plant REE patterns are probably not further fractionated by animals such as bovine during their dietary plant uptake

  2. Conceptual Design of Dielectric Accelerating Structures for Intense Neutron and Monochromatic X-ray Sources

    Science.gov (United States)

    Blanovsky, Anatoly

    2004-12-01

    Bright compact photon sources, which utilize electron beam interaction with periodic structures, may benefit a broad range of medical, industrial and scientific applications. A class of dielectric-loaded periodic structures for hard and soft X-ray production has been proposed that would provide a high accelerating gradient when excited by an external RF and/or primary electron beam. Target-distributed accelerators (TDA), in which an additional electric field compensates for lost beam energy in internal targets, have been shown to provide the necessary means to drive a high flux subcritical reactor (HFSR) for nuclear waste transmutation. The TDA may also be suitable for positron and nuclear isomer production, X-ray lithography and monochromatic computer tomography. One of the early assumptions of the theory of dielectric wake-field acceleration was that, in electrodynamics, the vector potential was proportional to the scalar potential. The analysis takes into consideration a wide range of TDA design aspects including the wave model of observed phenomena, a layered compound separated by a Van der Waals gap and a compact energy source based on fission electric cells (FEC) with a multistage collector. The FEC is a high-voltage power source that directly converts the kinetic energy of the fission fragments into electrical potential of about 2MV.

  3. Development and exploitation of the slit method for the characterization of x-ray screen-film combinations

    International Nuclear Information System (INIS)

    Hoeschen, D.

    1987-01-01

    For the determination of the modulation transfer function (MTF) of screen-film combinations which are used in medical x-ray diagnostics a measuring method has been developed: the screen-film combination is exposed to x-rays behind a thin slit and the modulation transfer function is calculated from the resulting rather broad slit images on the film. After solving many technical and photographic problems, the slit method provides high precision in the MTF determination. The only objection against this method is the necessary high dose variation which has to be provided by the x-ray machine

  4. A practical material decomposition method for x-ray dual spectral computed tomography.

    Science.gov (United States)

    Hu, Jingjing; Zhao, Xing

    2016-03-17

    X-ray dual spectral CT (DSCT) scans the measured object with two different x-ray spectra, and the acquired rawdata can be used to perform the material decomposition of the object. Direct calibration methods allow a faster material decomposition for DSCT and can be separated in two groups: image-based and rawdata-based. The image-based method is an approximative method, and beam hardening artifacts remain in the resulting material-selective images. The rawdata-based method generally obtains better image quality than the image-based method, but this method requires geometrically consistent rawdata. However, today's clinical dual energy CT scanners usually measure different rays for different energy spectra and acquire geometrically inconsistent rawdata sets, and thus cannot meet the requirement. This paper proposes a practical material decomposition method to perform rawdata-based material decomposition in the case of inconsistent measurement. This method first yields the desired consistent rawdata sets from the measured inconsistent rawdata sets, and then employs rawdata-based technique to perform material decomposition and reconstruct material-selective images. The proposed method was evaluated by use of simulated FORBILD thorax phantom rawdata and dental CT rawdata, and simulation results indicate that this method can produce highly quantitative DSCT images in the case of inconsistent DSCT measurements.

  5. Investigation of energy-relevant materials with synchrotron X-rays and neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Manke, Ingo; Markoetter, Henning; Kardjilov, Nikolay; Grothausmann, Roman; Haas, Sylvio; Thomas, Diana; Hoell, Armin; Genzel, Christoph [Helmholtz Centre Berlin for Materials and Energy, Berlin (Germany); Toetzke, Christian; Banhart, John [Helmholtz Centre Berlin for Materials and Energy, Berlin (Germany); Technische Universitaet Berlin (Germany). Materials Science and Technology; Dawson, Martin [Helmholtz Centre Berlin for Materials and Energy, Berlin (Germany); School of Computing, Science and Engineering, University of Salford (United Kingdom); Hartnig, Christoph [Chemetall GmbH, Frankfurt (Germany)

    2011-08-15

    Many materials used for energy conversion have a complex structure and chemical composition, knowledge of which is important for both understanding the function of materials and energy conversion systems and for their further development. Synchrotron radiation and neutrons can make an important contribution to understanding the function of such systems. Taking examples from the fields of fuel cells, gas separation membranes, batteries, solar cells, and catalysts, the use of radiography, tomography, diffraction, scattering, and absorption edge spectroscopy is demonstrated. The strength of such methods is the in situ characterization of processes and compositions, and so the focus is on these aspects. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  6. Quantitative analysis of scaling error compensation methods in dimensional X-ray computed tomography

    DEFF Research Database (Denmark)

    Müller, P.; Hiller, Jochen; Dai, Y.

    2015-01-01

    X-ray Computed Tomography (CT) has become an important technology for quality control of industrial components. As with other technologies, e.g., tactile coordinate measurements or optical measurements, CT is influenced by numerous quantities which may have negative impact on the accuracy...... errors of the manipulator system (magnification axis). This article also introduces a new compensation method for scaling errors using a database of reference scaling factors and discusses its advantages and disadvantages. In total, three methods for the correction of scaling errors – using the CT ball...

  7. Hard X-ray nanoimaging method using local diffraction from metal wire

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Hidekazu, E-mail: htakano@sci.u-hyogo.ac.jp; Konishi, Shigeki; Shimomura, Sho; Azuma, Hiroaki; Tsusaka, Yoshiyuki; Kagoshima, Yasushi [Center for Novel Material Science under Multi-Extreme Conditions, Graduate School of Material Science, University of Hyogo, Kamigori, Hyogo 678-1297 (Japan)

    2014-01-13

    A simple hard X-ray imaging method achieving a high spatial resolution is proposed. Images are obtained by scanning a metal wire through the wave field to be measured and rotating the sample to collect data for back projection calculations; the local diffraction occurring at the edges of the metal wire operates as a narrow line probe. In-line holograms of a test sample were obtained with a spatial resolution of better than 100 nm. The potential high spatial resolution of this method is shown by calculations using diffraction theory.

  8. Hydrogen Absorption in Metal Thin Films and Heterostructures Investigated in Situ with Neutron and X-ray Scattering

    Directory of Open Access Journals (Sweden)

    Sara J. Callori

    2016-05-01

    Full Text Available Due to hydrogen possessing a relatively large neutron scattering length, hydrogen absorption and desorption behaviors in metal thin films can straightforwardly be investigated by neutron reflectometry. However, to further elucidate the chemical structure of the hydrogen absorbing materials, complementary techniques such as high resolution X-ray reflectometry and diffraction remain important too. Examples of work on such systems include Nb- and Pd-based multilayers, where Nb and Pd both have strong affinity to hydrogen. W/Nb and Fe/Nb multilayers were measured in situ with unpolarized and polarized neutron reflectometry under hydrogen gas charging conditions. The gas-pressure/hydrogen-concentration dependence, the hydrogen-induced macroscopic film swelling as well as the increase in crystal lattice plane distances of the films were determined. Ferromagnetic-Co/Pd multilayers were studied with polarized neutron reflectometry and in situ ferromagnetic resonance measurements to understand the effect of hydrogen absorption on the magnetic properties of the system. This electronic effect enables a novel approach for hydrogen sensing using a magnetic readout scheme.

  9. Complementary X-ray and neutron radiography study of the initial lithiation process in lithium-ion batteries containing silicon electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Fu, E-mail: fu.sun@helmholtz-berlin.de [Institute of Material Science and Technologies, Technical University Berlin, 10623 Berlin (Germany); Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Markötter, Henning [Institute of Material Science and Technologies, Technical University Berlin, 10623 Berlin (Germany); Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Manke, Ingo; Hilger, André [Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Alrwashdeh, Saad S. [Institute of Material Science and Technologies, Technical University Berlin, 10623 Berlin (Germany); Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Mechanical Engineering Department, Faculty of Engineering, Mu' tah University, P.O. Box 7, Al-Karak 61710 Jordan (Jordan); Kardjilov, Nikolay [Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany); Banhart, John [Institute of Material Science and Technologies, Technical University Berlin, 10623 Berlin (Germany); Helmholtz Centre Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin (Germany)

    2017-03-31

    Highlights: • A radiography cell for in operando X-ray radiography was designed and built. • A self-assembled CR2032 coin cell was built for in operando neutron radiography. • In operando X-ray and neuron radiography were conducted by using Si electrode half cells. - Abstract: Complementary in operando X-ray radiography and neutron radiography measurements were conducted to investigate and visualize the initial lithiation in silicon-electrode lithium-ion batteries. By means of X-ray radiography, a significant volume expansion of Si particles and the Si electrode during the first discharge was observed. In addition, many Si particles were found that never undergo electrochemical reactions. These findings were confirmed by neutron radiography, which, for the first time, showed the process of Li alloying with the Si electrode during initial lithiation. These results demonstrate that complementary X-ray and neutron radiography is a powerful tool to investigate the lithiation mechanisms inside Si-electrode based lithium-ion batteries.

  10. Candidate isolated neutron stars and other optically blank x-ray fields identified from the rosat all-sky and sloan digital sky surveys

    Energy Technology Data Exchange (ETDEWEB)

    Agueros, Marcel A.; Anderson, Scott F.; /Washington U., Seattle, Astron. Dept.; Margon, Bruce; /Baltimore, Space Telescope Sci.; Haberl, Frank; Voges, Wolfgang; /Garching,; Annis, James; /Fermilab; Schneider, Donald P.; /Penn State U., Astron. Astrophys.; Brinkmann, Jonathan; /Apache Point Observ.

    2005-11-01

    Only seven radio-quiet isolated neutron stars (INSs) emitting thermal X rays are known, a sample that has yet to definitively address such fundamental issues as the equation of state of degenerate neutron matter. We describe a selection algorithm based on a cross-correlation of the ROSAT All-Sky Survey (RASS) and the Sloan Digital Sky Survey (SDSS) that identifies X-ray error circles devoid of plausible optical counterparts to the SDSS g {approx} 22 magnitudes limit. We quantitatively characterize these error circles as optically blank; they may host INSs or other similarly exotic X-ray sources such as radio-quiet BL Lacs, obscured AGN, etc. Our search is an order of magnitude more selective than previous searches for optically blank RASS error circles, and excludes the 99.9% of error circles that contain more common X-ray-emitting subclasses. We find 11 candidates, nine of which are new. While our search is designed to find the best INS candidates and not to produce a complete list of INSs in the RASS, it is reassuring that our number of candidates is consistent with predictions from INS population models. Further X-ray observations will obtain pinpoint positions and determine whether these sources are entirely optically blank at g {approx} 22, supporting the presence of likely isolated neutron stars and perhaps enabling detailed follow-up studies of neutron star physics.

  11. Determination of preferential molecular orientation in porphyrin-fullerene dyad ZnDHD6ee monolayers by the X-ray standing-wave method and X-ray reflectometry

    NARCIS (Netherlands)

    Seregin, A. Y.; D' Yakova, Y. A.; Yakunin, S. N.; Makhotkin, I. A.; Alekseev, A. S.; Klechkovskaya, V. V.; Tereschenko, E. Y.; Tkachenko, N. V.; Lemmetyinen, H.; Feigin, L. A.; Kovalchuk, M. V.

    2013-01-01

    Monolayers of porphyrin-fullerene dyad molecules with zinc atoms incorporated into the porphyrin ring (ZnDHD6ee) on the surface of aqueous subphase and on Si substrates have been investigated by the X-ray standing-wave method and X-ray reflectometry. The experiments have been performed under

  12. X-ray and neutron scattering investigations of YCo3-H

    International Nuclear Information System (INIS)

    Benham, M.J.; Bennington, S.M.; Ross, D.K.; Noreus, D.; Yamaguchi, M.

    1989-01-01

    Various structural studies of YCo 3 H(D) x in the β-phase (0 2 . Neutron diffraction and inelastic neutron scattering were also used in tandem, and hydrogen occupation of a single (36i) tetrahedral site was inferred for the entire concentration range. (orig.)

  13. Injection Methods and Instrumentation for Serial X-ray Free Electron Laser Experiments

    Science.gov (United States)

    James, Daniel

    Scientists have used X-rays to study biological molecules for nearly a century. Now with the X-ray free electron laser (XFEL), new methods have been developed to advance structural biology. These new methods include serial femtosecond crystallography, single particle imaging, solution scattering, and time resolved techniques. The XFEL is characterized by high intensity pulses, which are only about 50 femtoseconds in duration. The intensity allows for scattering from microscopic particles, while the short pulses offer a way to outrun radiation damage. XFELs are powerful enough to obliterate most samples in a single pulse. While this allows for a "diffract and destroy" methodology, it also requires instrumentation that can position microscopic particles into the X-ray beam (which may also be microscopic), continuously renew the sample after each pulse, and maintain sample viability during data collection. Typically these experiments have used liquid microjets to continuously renew sample. The high flow rate associated with liquid microjets requires large amounts of sample, most of which runs to waste between pulses. An injector designed to stream a viscous gel-like material called lipidic cubic phase (LCP) was developed to address this problem. LCP, commonly used as a growth medium for membrane protein crystals, lends itself to low flow rate jetting and so reduces the amount of sample wasted significantly. This work discusses sample delivery and injection for XFEL experiments. It reviews the liquid microjet method extensively, and presents the LCP injector as a novel device for serial crystallography, including detailed protocols for the LCP injector and anti-settler operation.

  14. Determination of U, Th and K in bricks by gamma-ray spectrometry, X-ray fluorescence analysis and neutron activation analysis

    Science.gov (United States)

    Bártová, H.; Kučera, J.; Musílek, L.; Trojek, T.; Gregorová, E.

    2017-11-01

    Knowledge of the content of natural radionuclides in bricks can be important in some cases in dosimetry and application of ionizing radiation. Dosimetry of naturally occurring radionuclides in matter (NORM) in general is one of them, the other one, related to radiation protection, is radon exposure evaluation, and finally, it is needed for the thermoluminescence (TL) dating method. The internal dose rate inside bricks is caused mostly by contributions of the natural radionuclides 238U, 232Th, radionuclides of their decay chains, and 40K. The decay chain of 235U is usually much less important. The concentrations of 238U, 232Th and 40K were measured by various methods, namely by gamma-ray spectrometry, X-ray fluorescence analysis (XRF), and neutron activation analysis (NAA) which was used as a reference method. These methods were compared from the point of view of accuracy, limit of detection (LOD), amount of sample needed and sample handling, time demands, and instrument availability.

  15. Comparison of various filtering methods for digital X-ray image processing

    International Nuclear Information System (INIS)

    Pfluger, T.; Reinfelder, H.E.; Dorschky, K.; Oppelt, A.; Siemens A.G., Erlangen

    1987-01-01

    Three filtering methods are explained and compared that are used for border edge enhancement of digitally processed X-ray images. The filters are compared by two examples, a radiograph of the chest, and one of the knee joint. The unsharpness mask is found to yield the best compromise between edge enhancement and image noise intensifying effect, whereas the results obtained by the high-pass filter or the Wallis filter are less good for diagnostic evaluation. The filtered images better display narrow lines, structural borders and edges, and finely spotted areas, than the original radiograph, so that diagnostic evaluation is easier after image filtering. (orig.) [de

  16. New analytical method for asbestos determination in Syrian soils using X-ray diffraction

    International Nuclear Information System (INIS)

    Kassem, M.

    2009-07-01

    In this work, a standard samples have been prepared by mixing a definite quantity of soil with calculated concentration of asbestos; 1, 2, 4, 8, 10, 20, 40, 60, 80, 100% wt . The samples have been analyzed by x-ray powder diffraction using the same parameters ; 2θ between 5-90, detector step= 0.5 /30 sec. The diffraction peaks intensities have been chosen such a manner than no superposition with those of the soil. confidence levels has been used as accuracy method for error calculation of the peaks positions. (author)

  17. A method for assessing the structural shielding in diagnostic x-ray facilities

    International Nuclear Information System (INIS)

    Almeida, F.; Martinez de la Fuente, O.; Perez, C.

    1992-01-01

    The design of each X-Ray medical facility involves, in order to guarantee the optimun levels of Radiologic safety for everybody who could be exposed during the performance of the examinations the need of assessing the required shieldings for the room which contains the emiter tubes. In such sense, this paper gives a number of criteria to calculate the structural requirements for the diverse configurations which exist in Health Centres using the method proposed by NCRP in its Report 49 as a reference. (author)

  18. A novel process control method for a TT-300 E-Beam/X-Ray system

    Science.gov (United States)

    Mittendorfer, Josef; Gallnböck-Wagner, Bernhard

    2018-02-01

    This paper presents some aspects of the process control method for a TT-300 E-Beam/X-Ray system at Mediscan, Austria. The novelty of the approach is the seamless integration of routine monitoring dosimetry with process data. This allows to calculate a parametric dose for each production unit and consequently a fine grain and holistic process performance monitoring. Process performance is documented in process control charts for the analysis of individual runs as well as historic trending of runs of specific process categories over a specified time range.

  19. Study Of Soot Growth And Nucleation By A Time-Resolved Synchrotron Radiation Based X-Ray Absorption Method

    National Research Council Canada - National Science Library

    Mitchell, Judith I

    2001-01-01

    This report results from a contract tasking University of Rennes I as follows: The contractor will perform a study of soot growth and nucleation by a time-resolved synchrotron radiation based x-ray absorption method...

  20. Application of proton-induced X-ray emission method to determination of lead content in blood

    International Nuclear Information System (INIS)

    Slominska, D.; Jarczyk, L.; Rokita, E.; Strzalkowski, A.; Losiowski, A.; Macheta, A.; Sych, M.; Moszkowicz, S.

    1979-01-01

    The proton induced X-ray emission method is applied for determination of lead content in the blood of the people exposed to contact with ethyline vapours and people working in lead-zinc works. (author)

  1. Finite difference method calculations of X-ray absorption fine structure for copper

    Energy Technology Data Exchange (ETDEWEB)

    Bourke, J.D. [School of Physics, University of Melbourne, Parkville, Vic 3010 (Australia); Chantler, C.T. [School of Physics, University of Melbourne, Parkville, Vic 3010 (Australia)]. E-mail: chantler@physics.unimelb.edu.au; Witte, C. [School of Physics, University of Melbourne, Parkville, Vic 3010 (Australia)

    2007-01-15

    The finite difference method is extended to calculate X-ray absorption fine structure (XAFS) for solid state copper. These extensions include the incorporation of a Monte Carlo frozen phonon technique to simulate the effect of thermal vibrations under a correlated Debye-Waller model, and the inclusion of broadening effects from inelastic processes. Spectra are obtained over an energy range in excess of 300 eV above the K absorption edge-more than twice the greatest energy range previously reported for a solid state calculation using this method. We find this method is highly sensitive to values of the photoelectron inelastic mean free path, allowing us to probe the accuracy of current models of this parameter, particularly at low energies. We therefore find that experimental data for the photoelectron inelastic mean free path can be obtained by this method. Our results compare favourably with high precision measurements of the X-ray mass attenuation coefficient for copper, reaching agreement to within 3%, and improving previous results using the finite difference method by an order of magnitude.

  2. New X-ray testing methods of aerosol products for industrial radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bozydar Knyziak, Adrian, E-mail: a.knyziak@gum.gov.pl; Rzodkiewicz, Witold, E-mail: w.rzodkiewicz@gum.gov.pl; Kaczorowska, Ewa, E-mail: e.kaczorowska@gum.gov.pl; Derlacinski, Michal, E-mail: m.derlacinski@gum.gov.pl

    2017-02-01

    An amount of product in e.g. an aerosol canister is not difficult to estimate by weighing a filled can and subtracting the tare of packaging. In this way, we can obtain the net weight of the ingredients present in the can. Although, this does not indicate the volumetric content. Therefore, in the paper, the fundamental (the weight method and given by FEICA) and new methods (given by authors) related to the determination of the volumetric content of canister filled with aeorosol products are presented. The new methods are based on direct digital radiography (DR) using X-ray radiation. For the needs of new methods, the X-ray CCD-DR imaging system was built and developed in our Laboratory in Department of Radiation and Vibration at the Central Office of Measures. For comparison purposes, with regard to the volumetric content, a lot of metal cans of capacities 140, 185, 450, 700 ml were inspected. In future, computed tomography (CT) for industrial radiography in our laboratory will be used. Currently, an algorithm for CT is being tested. It will give us possibility for very precise measurements to determine volumetric content of examined canisters.

  3. Dose-incidence relationships for exencephalia, anophthalmia and prenatal mortality in mouse embryos irradiated with fission neutrons or 250 kV X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Friedberg, W.; Faulkner, D.N.; Neas, B.R.; Hanneman, G.D.; Darden, E.B. Jr.; Deal, R.B. Jr.; Parker, D.E.

    1987-08-01

    Groups of pregnant mice were irradiated at selected times between 10.00 hours on gestation day 7 and 16.00 hours on day 8. Each group received 0.39 Gy of neutrons or 1.60 Gy of X-rays, or was sham irradiated. We identified a period of high susceptibility of the embryos to radiation-induced exencephalia, anophthalmia and prenatal mortality early in gestation day 8. Dose-incidence relationships in this period were investigated with 0.19-0.48 Gy of neutrons and with 0.40-2.00 Gy of X-rays.

  4. Dose-incidence relationships for exencephalia, anophthalmia and prenatal mortality in mouse embryos irradiated with fission neutrons or 250 kV X-rays

    International Nuclear Information System (INIS)

    Friedberg, W.; Faulkner, D.N.; Neas, B.R.; Hanneman, G.D.; Deal, R.B. Jr.; Parker, D.E.

    1987-01-01

    Groups of pregnant mice were irradiated at selected times between 10.00 hours on gestation day 7 and 16.00 hours on day 8. Each group received 0.39 Gy of neutrons or 1.60 Gy of X-rays, or was sham irradiated. We identified a period of high susceptibility of the embryos to radiation-induced exencephalia, anophthalmia and prenatal mortality early in gestation day 8. Dose-incidence relationships in this period were investigated with 0.19-0.48 Gy of neutrons and with 0.40-2.00 Gy of X-rays. (author)

  5. Structural and magnetic properties of transition metal substituted BaFe2As2 compounds studied by x-ray and neutron scattering

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Gyu [Iowa State Univ., Ames, IA (United States)

    2012-01-01

    The purpose of my dissertation is to understand the structural and magnetic properties of the newly discovered FeAs-based superconductors and the interconnection between superconductivity, antiferromagnetism, and structure. X-ray and neutron scattering techniques are powerful tools to directly observe the structure and magnetism in this system. I used both x-ray and neutron scattering techniques on different transition substituted BaFe2As2 compounds in order to investigate the substitution dependence of structural and magnetic transitions and try to understand the connections between them.

  6. Crystal structure of non-stoichiometric copper selenides studied by neutron scattering and X-ray diffraction

    International Nuclear Information System (INIS)

    Bikkulova, N.N.; Yagafarova, Z.A.; Asylguzhina, G.N.; Danilkin, S.A.; Fuess, H.; Skomorokhov, A.N.; Yadrovskii, E.L.; Beskrovnyi, A.I.

    2003-01-01

    Structural characteristics of non-stoichiometric copper selenides were studied by the elastic neutron and X-ray scattering techniques. Rietveld analysis was used to refine the structure of the high-temperature β-phase of the Cu 1.75 Se, Cu 1.78 Se, and Cu 1.83 Se samples. The homogeneity ranges of the cubic phase were determined. The modification of the crystal structure accompanying the β-α phase transition was studied for Cu 1.75 Se and Cu 1.98 Se compounds within the 443-10 K temperature range. It was shown that the phase transition is accompanied by distortions of the fcc lattice and the ordering of copper ions

  7. Preliminary homogeneity study of in-house reference material using neutron activation analysis and X-ray fluorescence

    International Nuclear Information System (INIS)

    Gras, N.; Munoz, L.; Cassorla, V.; Castillo, P.

    1993-01-01

    Although many biological reference materials for quality control of trace element analysis are commercially available, there is still a need for additional local materials for special matrices. In the Latin American region a preliminary study has been commenced involving analytical strategies for the characterization of in-house reference material. A biological sample, prepared in Brazil, constitutes the first regional attempt to prepare reference material. It was analyzed by neutron activation analysis (NAA) and X-ray fluorescence (XRF) to verify its homogeneity. The determination of the trace elements and certain major elements was carried out by instrumental NAA. Trace elements such as Cd, Mn, Mo and Cu were determined using NAA with radiochemical separations to improve the sensitivity and precision. XRF was applied only to major constituents and some trace elements with concentration of more than 10 μg/g. From a total of 18 elements analyzed, only Fe, Cr and Sc were not homogeneously distributed. (orig.)

  8. Structure of Se-Te glasses studied using neutron, X-ray diffraction and reverse Monte Carlo modelling

    Energy Technology Data Exchange (ETDEWEB)

    Itoh, Keiji, E-mail: itoh@okayama-u.ac.jp [Graduate School of Education, Okayama University, Tsushima-naka, Okayama 700-8530 (Japan); Research Reactor Institute, Kyoto University, Kumatori, Osaka 590-0494 (Japan)

    2017-02-15

    Pulsed neutron diffraction and synchrotron X-ray diffraction measurements were performed on Se{sub 100-x}Te{sub x} bulk glasses with x=10, 20, 30 and 40. The coordination numbers obtained from the diffraction results demonstrate that Se and Te atoms are twofold coordinated and the glass structure is formed by the chain network. The three-dimensional structure model for Se{sub 60}Te{sub 40} glass obtained by using reverse Monte Carlo modelling shows that the alternating arrangements of Se and Te atoms compose the major part of the chain clusters but several other fragments such as Se{sub n} chains and Te-Te dimers are also present in large numbers. The chain clusters have geometrically disordered forms and the interchain atomic order is different from those in the crystal structures of trigonal Se and trigonal Te. - Graphical abstract: Coordination environment in Se{sub 60}Te{sub 40} glass.

  9. Nanostructure of polymer monolayer and polyelectrolyte brush at air/water interface by X-ray and neutron reflectometry

    CERN Document Server

    Matsuoka, H; Matsumoto, K

    2003-01-01

    The nanostructure of amphiphilic diblock copolymer monolayer on water was directly investigated by in situ X-ray and neutron reflectivity techniques. The diblock copolymer consists of polysilacyclobutane, which is very flexible, as a hydrophobic block and polymethacrylic acid, an anionic polymer, as a hydrophilic block. The polymers with shorter hydrophilic segment formed a very smooth and uniform monolayer with hydrophobic layer on water and dense hydrophilic layer under the water. But the longer hydrophilic segment polymer formed three-layered monolayer with polyelectrolyte brush in addition to hydrophobic and dense hydrophilic layers. The dense hydrophilic layer is thought to be formed to avoid a contact between hydrophobic polymer layer and water. Its role is something like a 'carpet'. An additional interesting information is that the thickness of the 'carpet layer' is almost 15A, independent the surface pressure and hydrophilic polymer length. Highly quantitative information was obtained about the nanost...

  10. Interfacial mixing in as-deposited Si/Ni/Si layers analyzed by x-ray and polarized neutron reflectometry

    Science.gov (United States)

    Bhattacharya, Debarati; Basu, Saibal; Singh, Surendra; Roy, Sumalay; Dev, Bhupendra Nath

    2012-12-01

    Interdiffusion occurring across the interfaces in a Si/Ni/Si layered system during deposition at room temperature was probed using x-ray reflectivity (XRR) and polarized neutron reflectivity (PNR). Exploiting the complementarity of these techniques, both structural and magnetic characterization with nanometer depth resolution could be achieved. Suitable model fitting of the reflectivity profiles identified the formation of Ni-Si mixed alloy layers at the Si/Ni and Ni/Si interfaces. The physical parameters of the layered structure, including quantitative assessment of the stoichiometry of interfacial alloys, were obtained from the analyses of XRR and PNR patterns. In addition, PNR provided magnetic moment density profile as a function of depth in the stratified medium.

  11. Major and minor elements analysis in soil samples by neutron activation analysis and X-ray fluorescence

    International Nuclear Information System (INIS)

    Morcelli, Claudia Petronilho Ribeiro; Ana Maria Graciano; Enzweiler, Jacinta

    2002-01-01

    In the present work, Instrumental Neutron Activation Analysis (INAA) and X-Ray Fluorescence were employed to analyze major and minor elements in soil samples collected near Bandeirantes road. Elements of environmental interest, such as Al, Sb, As, Ba, Cd, Pb, Co, Cu, Cr, Fe, Mn, Mo, Ni, Se, V and Zn, which have reference background levels, were determined. The samples were dried in an oven at 40 deg C, were sieved (<2 mm), grinded and were analyzed by INAA and FRX. The aims of this work were: to evaluate the possible variations in the concentration levels in soil due to emission of particulate from vehicles and other anthropogenic sources; to compare the results obtained by using both techniques. This preliminary study showed that the concentration levels of the elements of environmental interest agree with reference values for tropical soils in the sampling sites, except for Ba, which presented higher values. (author)

  12. Advanced neutron and X-ray techniques for insights into the microstructure of EB-PVD thermal barrier coatings

    Energy Technology Data Exchange (ETDEWEB)

    Kulkarni, Anand [State University of New York, Stony Brook, NY 11794 (United States); Goland, Allen [State University of New York, Stony Brook, NY 11794 (United States); Herman, Herbert [State University of New York, Stony Brook, NY 11794 (United States)]. E-mail: hherman@ms.cc.sunysb.edu; Allen, Andrew J. [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Dobbins, Tabbetha [National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); DeCarlo, Francesco [Argonne National Laboratory, Argonne, IL 60439 (United States); Ilavsky, Jan [Argonne National Laboratory, Argonne, IL 60439 (United States); Long, Gabrielle G. [Argonne National Laboratory, Argonne, IL 60439 (United States); Fang, Stacy [Chromalloy Gas Turbine Corporation, Orangeburg, NY 10962 (United States); Lawton, Paul [Chromalloy Gas Turbine Corporation, Orangeburg, NY 10962 (United States)

    2006-06-25

    The ongoing quest to increase gas turbine efficiency and performance (increased thrust) provides a driving force for materials development. While improved engine design and usage of novel materials provide solutions for increased engine operating temperatures, and hence fuel efficiency, reliability issues remain. Thermal barrier coatings (TBCs), deposited onto turbine components using the electron-beam physical vapor deposition (EB-PVD) process, exhibit unique pore architectures capable of bridging the technological gap between insulation/life extension and prime reliance. This article explores the potential of advanced X-ray and neutron techniques for comprehension of an EB-PVD TBC coating microstructure. While conventional microscopy reveals a hierarchy of voids, complementary advanced techniques allow quantification of these voids in terms of component porosities, anisotropy, size and gradient through the coating thickness. In addition, the derived microstructural parameters obtained both further knowledge of the nature and architecture of the porosity, and help establish its influence on the resultant thermal and mechanical properties.

  13. System Characterizations and Optimized Reconstruction Methods for Novel X-ray Imaging Modalities

    Science.gov (United States)

    Guan, Huifeng

    In the past decade there have been many new emerging X-ray based imaging technologies developed for different diagnostic purposes or imaging tasks. However, there exist one or more specific problems that prevent them from being effectively or efficiently employed. In this dissertation, four different novel X-ray based imaging technologies are discussed, including propagation-based phase-contrast (PB-XPC) tomosynthesis, differential X-ray phase-contrast tomography (D-XPCT), projection-based dual-energy computed radiography (DECR), and tetrahedron beam computed tomography (TBCT). System characteristics are analyzed or optimized reconstruction methods are proposed for these imaging modalities. In the first part, we investigated the unique properties of propagation-based phase-contrast imaging technique when combined with the X-ray tomosynthesis. Fourier slice theorem implies that the high frequency components collected in the tomosynthesis data can be more reliably reconstructed. It is observed that the fringes or boundary enhancement introduced by the phase-contrast effects can serve as an accurate indicator of the true depth position in the tomosynthesis in-plane image. In the second part, we derived a sub-space framework to reconstruct images from few-view D-XPCT data set. By introducing a proper mask, the high frequency contents of the image can be theoretically preserved in a certain region of interest. A two-step reconstruction strategy is developed to mitigate the risk of subtle structures being oversmoothed when the commonly used total-variation regularization is employed in the conventional iterative framework. In the thirt part, we proposed a practical method to improve the quantitative accuracy of the projection-based dual-energy material decomposition. It is demonstrated that applying a total-projection-length constraint along with the dual-energy measurements can achieve a stabilized numerical solution of the decomposition problem, thus overcoming the

  14. Effect of anisotropy on the sticking in muon-catalyzed fusion determined by the x-ray method

    International Nuclear Information System (INIS)

    Cohen, J.S.; Padial, N.T.

    1989-01-01

    The initial sticking in the 2p/sub m/ states of muonic helium in muon-catalyzed fusion (μCF) and the subsequent collisional excitation to these states are shown to have nonstatistical dependences on m that result in spatial anisotropy of the emitted x rays. This anisotropy, I(0 0 )/I(90 0 ), is found to be 0.71 for d-d μCF and 1.12 for d-t μCF in liquid targets, where the angle is between the coincidentally detected x ray and neutron. The effect is predicted to increase the actual Kα x-ray yield and corresponding sticking observed in a recent d-t μCF experiment by 4%. The Doppler broadening of the radiation observed at different angles is also examined

  15. Characterization of solid specimens from environmental pollution studies using electron x-ray and nuclear physics methods

    International Nuclear Information System (INIS)

    Hulett, L.D.; Dunn, H.W.; Dale, J.M.; Emery, J.F.; Lyon, W.S.; Murty, P.S.

    1976-01-01

    This paper illustrates how the properties of environmental particulate matter can be better understood if a multitechnique examination is conducted. Some results for fly ash, using neutron activation analysis, scanning electron microscopy, photoelectron spectroscopy (ESCA), x-ray fluorescence and x-ray diffraction are described. The difference in composition between the surfaces and interiors of particles are discussed and the effects of water leaching on surface composition are shown. The propensity of natural iron oxide substrates to cover themselves with adsorbed material is illustrated; this may be an important factor in the transfer of pollutants on particulate matter surfaces. The final section describes how the element detection sensitivity can be predicted for an improved x-ray fluorescence system that uses monochromatic AgKα radiation for excitation

  16. Detection of moving capillary front in porous rocks using X-ray and ultrasonic methods

    Directory of Open Access Journals (Sweden)

    Christian eDavid

    2015-07-01

    Full Text Available Several methods are compared for the detection of moving capillary fronts in spontaneous imbibition experiments where water invades dry porous rocks. These methods are: (i the continuous monitoring of the mass increase during imbibition, (ii the imaging of the water front motion using X-ray CT scanning, (iii the use of ultrasonic measurements allowing the detection of velocity, amplitude and spectral content of the propagating elastic waves, and (iv the combined use of X-ray CT scanning and ultrasonic monitoring. It is shown that the properties of capillary fronts depend on the heterogeneity of the rocks, and that the information derived from each method on the dynamics of capillary motion can be significantly different. One important result from the direct comparison of the moving capillary front position and the P wave attributes is that the wave amplitude is strongly impacted before the capillary front reaches the sensors, in contrast with the velocity change which is concomitant with the fluid front arrival in the sensors plane.

  17. X ray Production. Chapter 5

    Energy Technology Data Exchange (ETDEWEB)

    Nowotny, R. [Medical University of Vienna, Vienna (Austria)

    2014-09-15

    The differential absorption of X rays in tissues and organs, owing to their atomic composition, is the basis for the various imaging methods used in diagnostic radiology. The principles in the production of X rays have remained the same since their discovery. However, much refinement has gone into the design of X ray tubes to achieve the performance required for today’s radiological examinations. In this chapter, an outline of the principles of X ray production and a characterization of the radiation output of X ray tubes will be given. The basic processes producing X rays are dealt with in Section 1.4.

  18. Neutron and high-contrast X-ray micro-radiography as complementary tools for monitoring organosilicon consolidants in natural building stones

    Energy Technology Data Exchange (ETDEWEB)

    Slavíková, Monika, E-mail: Monika.Slavikova@vscht.cz [Department of Chemical Technology of Monuments Conservation, Institute of Chemical Technology in Prague, Prague 6 CZ-16628 (Czech Republic); Krejčí, František [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Prague 2 CZ-12800 (Czech Republic); Kotlík, Petr [Department of Chemical Technology of Monuments Conservation, Institute of Chemical Technology in Prague, Prague 6 CZ-16628 (Czech Republic); Jakůbek, Jan [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Prague 2 CZ-12800 (Czech Republic); Tomandl, Ivo; Vacík, Jiří [Nuclear Physics Institute, Academy of Sciences of the Czech Republic, CZ-25800, Rez Near Prague (Czech Republic)

    2014-11-01

    The monitoring of consolidants and other treatment product in stones is currently of great importance in various restoration studies. We use neutron and high-contrast X-ray micro-radiography as complementary non-destructive techniques for monitoring of organosilicon consolidants in the Opuka stone. Thanks to different sensitivities of both techniques in relation to the elemental composition, the effect of addition of the contrast agent (3-iodopropyl)trimethoxysilane commonly used in stone consolidation monitoring with X-ray radiography is evaluated. As the addition of the contrast agent to the original consolidation product alters important parameters such as the penetration depth, the understanding of the behaviour of the modified consolidation mixture is essential for verification of the reliability of the method. By comparing results from both methods, the respective radiographs show consistency in terms of homogeneity and penetration depth for all investigated concentrations of the used contrast agent. The presented results further demonstrate that the application of the contrast agent apparently changes the penetration depth, but these changes are, especially for very low concentrations (up to 1%) for most of the studies needed, negligible.

  19. A novel method of microneedle array fabrication using inclined deep x-ray exposure

    International Nuclear Information System (INIS)

    Moon, Sang Jun; Jin, Chun Yan; Lee, Seung S

    2006-01-01

    We report a novel fabrication method for the microneedle array with a 3-dimensional feature and its replication method; 'Hot-pressing' process with bio-compatible material, PLLA (Poly L-LActide). Using inclined deep X-ray exposure technique, we fabricate a band type microneedle array with a single body on the same material basement. Since the single body feature does not make adhesion problem with the microneedle shank and basement during peel-off step of a mold, the PMMA (Poly-Methyl-MethAcrylate) microneedle array mold insert can be used for mold process which is used with the soft material mold, PDMS (Poly-Di- Methyl-Siloxane). The side inclined deep X-ray exposure also makes complex 3-dimensional features by the regions which are not exposed during twice successive exposure steps. In addition, the successive exposure does not need an additional mask alignment after the first side exposure. The fabricated band type microneedle array mold inserts are assembled for large area patch type out-of-plane microneedle array. The bio-compatible microneedle array can be fabricated to the laboratory scale mass production by the single body PMMA mold insert and 'Hot-pressing' process

  20. A novel method of microneedle array fabrication using inclined deep x-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sang Jun; Jin, Chun Yan; Lee, Seung S [Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 373-1, Guseong-dong, Yuseong-dong, Daejeon (Korea, Republic of)

    2006-04-01

    We report a novel fabrication method for the microneedle array with a 3-dimensional feature and its replication method; 'Hot-pressing' process with bio-compatible material, PLLA (Poly L-LActide). Using inclined deep X-ray exposure technique, we fabricate a band type microneedle array with a single body on the same material basement. Since the single body feature does not make adhesion problem with the microneedle shank and basement during peel-off step of a mold, the PMMA (Poly-Methyl-MethAcrylate) microneedle array mold insert can be used for mold process which is used with the soft material mold, PDMS (Poly-Di- Methyl-Siloxane). The side inclined deep X-ray exposure also makes complex 3-dimensional features by the regions which are not exposed during twice successive exposure steps. In addition, the successive exposure does not need an additional mask alignment after the first side exposure. The fabricated band type microneedle array mold inserts are assembled for large area patch type out-of-plane microneedle array. The bio-compatible microneedle array can be fabricated to the laboratory scale mass production by the single body PMMA mold insert and 'Hot-pressing' process.