WorldWideScience

Sample records for methods manual vol

  1. Technical reference manual for TIME4. Vol. 2

    International Nuclear Information System (INIS)

    Wilmot, R.D.; Ringrose, P.S.; Larkin, J.P.A.; Kleissen, F.A.T.

    1991-07-01

    This document is the Technical Reference Manual for the TIME4 model. TIME4 is the environmental change model developed for use in the probabilistic risk analysis of deep disposal of radioactive waste. The Technical Reference Manual describes the theoretical background to the model. The modelling method is described, followed by a review of related work and a detailed description for each sub-model. (author)

  2. Maintenance manual. Vol. 1. Maintenance management; 2. completely rev. ed.; Handbuch Instandhaltung. Bd. 1. Instandhaltungsmanagement

    Energy Technology Data Exchange (ETDEWEB)

    Warnecke, H.J. [ed.] [Fraunhofer-Institut fuer Produktionstechnik und Automatisierung (IPA), Stuttgart (Germany)

    1992-12-31

    This manual is the second, completely revised edition of the standard manual ``Maintenance - Fundamentals``, which was first published in 1981. It presents an outline of all relevant fields of maintenance today and contains practical information on new and established methods of maintenance management and technology. With its comprehensive concept, which addresses any industrial enterprise that wants to remain competitive, the manual is indispensable for maintenance managers in industry, service enterprises and consultancies. Vol.1, ``Maintenance Management``, informs the reader on fundamentals, design with a view to maintenance, organisation of maintenance work, personnel management, industrial safety and economic aspects of maintenance. Current issues such as product liability, electronic data processing, expert systems, environmental protection, controlling based on characteristic data, etc. are gone into. Graphical representations, concrete procedural information and exemplary solutions may be used directly as working tools for the practice of maintenance. (orig.) [Deutsch] Das vorliegende Handbuch ist die zweite, voellig ueberarbeitete und erweiterte Auflage des Standardwerkes ``Instandhaltung - Grundlagen``, das 1981 erstmals erschien. Es gibt einen Ueberblick ueber alle relevanten Gebiete einer modernen Instandhaltung und vermittelt praxisnahes Wissen ueber neue und bewaehrte Methoden und Verfahren des Instandhaltungsmanagements und der Instandhaltungstechnik. Mit dieser umfassenden Konzeption, die auf die Belange des im Wettbewerb stehenden Industriebetriebes ausgerichtet ist, wendet sich das Handbuch an die Fuehrungskraefte der Instandhaltung in der Industrie sowie an Dienstleistungs- und Beratungsunternehmen. Im Band 1 ``Instandhaltungsmanagement`` kann sich der Leser ueber Grundlagen, instandhaltungsgerechtes Konstruieren, Organisation der Instandhaltung, Personalmanagement, Arbeitssicherheit sowie Wirtschaftlichkeit der Instandhaltung informieren

  3. Accountability methods for plutonium and uranium: the NRC manuals

    Energy Technology Data Exchange (ETDEWEB)

    Gutmacher, R.G.; Stephens, F.B.

    1977-09-28

    Four manuals containing methods for the accountability of plutonium nitrate solutions, plutonium dioxide, uranium dioxide and mixed uranium-plutonium oxide have been prepared by us and issued by the U.S. Nuclear Regulatory Commission. A similar manual on methods for the accountability of uranium and plutonium in reprocessing plant dissolver solutions is now in preparation. In the present paper, we discuss the contents of the previously issued manuals and give a preview of the manual now being prepared.

  4. Accountability methods for plutonium and uranium: the NRC manuals

    International Nuclear Information System (INIS)

    Gutmacher, R.G.; Stephens, F.B.

    1977-01-01

    Four manuals containing methods for the accountability of plutonium nitrate solutions, plutonium dioxide, uranium dioxide and mixed uranium-plutonium oxide have been prepared by us and issued by the U.S. Nuclear Regulatory Commission. A similar manual on methods for the accountability of uranium and plutonium in reprocessing plant dissolver solutions is now in preparation. In the present paper, we discuss the contents of the previously issued manuals and give a preview of the manual now being prepared

  5. Radioanalytical methods manual

    International Nuclear Information System (INIS)

    Chiu, N.W.; Dean, J.R.

    1986-01-01

    This Radioanalytical Methods manual is comprised of 12 chapters. It includes a review of the pertinent literature up to the end of 1982 pertaining to the measurement of the radioactive species listed under the terms of the contract. Included is methodology recommended for the decompositions of soils, tailings, ores, biological samples and air filters. Detailed analytical methodology for the measurement of gross alpha, gross beta, gross gamma, uranium, radium-226, radium-228, lead-210, thorium-232, thorium-230, thorium-228, total thorium, radon-222, radon-220 and radon-219 is presented

  6. Transuranic waste characterization sampling and analysis methods manual. Revision 1

    International Nuclear Information System (INIS)

    Suermann, J.F.

    1996-04-01

    This Methods Manual provides a unified source of information on the sampling and analytical techniques that enable Department of Energy (DOE) facilities to comply with the requirements established in the current revision of the Transuranic Waste Characterization Quality Assurance Program Plan (QAPP) for the Waste Isolation Pilot Plant (WIPP) Transuranic (TRU) Waste Characterization Program (the Program) and the WIPP Waste Analysis Plan. This Methods Manual includes all of the testing, sampling, and analytical methodologies accepted by DOE for use in implementing the Program requirements specified in the QAPP and the WIPP Waste Analysis Plan. The procedures in this Methods Manual are comprehensive and detailed and are designed to provide the necessary guidance for the preparation of site-specific procedures. With some analytical methods, such as Gas Chromatography/Mass Spectrometry, the Methods Manual procedures may be used directly. With other methods, such as nondestructive characterization, the Methods Manual provides guidance rather than a step-by-step procedure. Sites must meet all of the specified quality control requirements of the applicable procedure. Each DOE site must document the details of the procedures it will use and demonstrate the efficacy of such procedures to the Manager, National TRU Program Waste Characterization, during Waste Characterization and Certification audits

  7. Manual method for dose calculation in gynecologic brachytherapy

    International Nuclear Information System (INIS)

    Vianello, Elizabeth A.; Almeida, Carlos E. de; Biaggio, Maria F. de

    1998-01-01

    This paper describes a manual method for dose calculation in brachytherapy of gynecological tumors, which allows the calculation of the doses at any plane or point of clinical interest. This method uses basic principles of vectorial algebra and the simulating orthogonal films taken from the patient with the applicators and dummy sources in place. The results obtained with method were compared with the values calculated with the values calculated with the treatment planning system model Theraplan and the agreement was better than 5% in most cases. The critical points associated with the final accuracy of the proposed method is related to the quality of the image and the appropriate selection of the magnification factors. This method is strongly recommended to the radiation oncology centers where are no treatment planning systems available and the dose calculations are manually done. (author)

  8. Validity of a manual soft tissue profile prediction method following mandibular setback osteotomy.

    Science.gov (United States)

    Kolokitha, Olga-Elpis

    2007-10-01

    The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication.

  9. Diagnostic Value of Manual and Computerized Methods of Dental Casts Analysis

    Directory of Open Access Journals (Sweden)

    H. Rahimi

    2009-06-01

    Full Text Available Objective: The aim of this study was to evaluate the validity of computerized and manual methods of dental cast analysis.Materials and Methods: Twenty set-ups of upper and lower casts using artificial teeth corresponding to various malocclusions were created for a diagnostic in vitro study. Values of tooth size were calculated from the isolated artificial teeth out of the set-ups, results were considered as a gold standard for the tooth size. Arch width was calculated from the existing set-ups on the dentins.Impressions were taken of the casts with alginate and duplicated with dental stone. Models were measured with digital caliper manually. Then images were taken from the occlusal views of the casts by a digital camera. Measurements were done on digital images with the AutoCAD software.The results of the computerized and manual methods were compared with the gold standard.Intra class correlation coefficient of reliability was used to measure the accuracy ofthe methods and the Friedman technique used to evaluate the significance of differences.Results: Results indicated that all measurements were highly correlated, e.g. gold standard and manual (0.9613-0.9991, gold standard and computerized (0.7118-0.9883, manual and computerized (0.6734-0.9914. Statistically significant differences were present between these methods (P<0.05, but they proved not to be clinically significant.Conclusion: Manual measurement is still the most accurate method when compared to the computerized measurements and the results of measurement by computer should be interpreted with caution.

  10. 1H MR spectroscopy of the normal human brains : comparison of automated prescan method with manual method

    International Nuclear Information System (INIS)

    Lim, Myung Kwan; Suh, Chang Hae; Cho, Young Kook; Kim, Jin Hee

    1998-01-01

    The purpose of this paper is to evaluate regional differences in relative metabolite ratios in the normal human brain by 1 H MR spectroscopy (MRS), and compare the spectral quality obtained by the automated prescan method (PROBE) and the manual method. A total of 61 reliable spectra were obtained by PROBE (28/34=82% success) and by the manual method (33/33=100% success). Regional differences in the spectral patterns of the five regions were clearly demonstrated by both PROBE and the manual methods. for prescanning, the manual method took slightly longer than PROBE (3-5 mins and 2 mins, respectively). There were no significant differences in spectral patterns and relative metabolic ratios between the two methods. However, auto-prescan by PROBE seemed to be very vulnerable to slight movement by patients, and in three cases, an acceptable spectrum was thus not obtained. PROBE is a highly practical and reliable method for single voxel 1 H MRS of the human brain; the two methods of prescanning do not result in significantly different spectral patterns and the relative metabolite ratios. PROBE, however, is vulnerable to slight movement by patients, and if the success rate for obtaining quality spectra is to be increased, regardless of the patient's condition and the region of the brain, it must be used in conjunction with the manual method. (author). 23 refs., 2 tabs., 3 figs

  11. Manual of selected physico-chemical analytical methods. IV

    International Nuclear Information System (INIS)

    Beran, M.; Klosova, E.; Krtil, J.; Sus, F.; Kuvik, V.; Vrbova, L.; Hamplova, M.; Lengyel, J.; Kelnar, L.; Zakouril, K.

    1990-11-01

    The Central Testing Laboratory of the Nuclear Research Institute at Rez has for a decade been participating in the development of analytical procedures and has been providing analyses of samples of different types and origin. The analytical procedures developed have been published in special journals and a number of them in the Manuals of analytical methods, in three parts. The 4th part of the Manual contains selected physico-chemical methods developed or modified by the Laboratory in the years 1986-1990 within the project ''Development of physico-chemical analytical methods''. In most cases, techniques are involved for non-nuclear applications. Some can find wider applications, especially in analyses of environmental samples. Others have been developed for specific cases of sample analyses or require special instrumentation (mass spectrometer), which partly restricts their applicability by other institutions. (author)

  12. Comparison of manual and automated quantification methods of 123I-ADAM

    International Nuclear Information System (INIS)

    Kauppinen, T.; Keski-Rahkonen, A.; Sihvola, E.; Helsinki Univ. Central Hospital

    2005-01-01

    123 I-ADAM is a novel radioligand for imaging of the brain serotonin transporters (SERTs). Traditionally, the analysis of brain receptor studies has been based on observer-dependent manual region of interest definitions and visual interpretation. Our aim was to create a template for automated image registrations and volume of interest (VOI) quantification and to show that an automated quantification method of 123 I-ADAM is more repeatable than the manual method. Patients, methods: A template and a predefined VOI map was created from 123 I-ADAM scans done for healthy volunteers (n=15). Scans of another group of healthy persons (HS, n=12) and patients with bulimia nervosa (BN, n=10) were automatically fitted to the template and specific binding ratios (SBRs) were calculated by using the VOI map. Manual VOI definitions were done for the HS and BN groups by both one and two observers. The repeatability of the automated method was evaluated by using the BN group. Results: For the manual method, the interobserver coefficient of repeatability was 0.61 for the HS group and 1.00 for the BN group. The intra-observer coefficient of repeatability for the BN group was 0.70. For the automated method, the coefficient of repeatability was 0.13 for SBRs in midbrain. Conclusion: An automated quantification gives valuable information in addition to visual interpretation decreasing also the total image handling time and giving clear advantages for research work. An automated method for analysing 123 I-ADAM binding to the brain SERT gives repeatable results for fitting the studies to the template and for calculating SBRs, and could therefore replace manual methods. (orig.)

  13. A manual of analytical methods used at MINTEK

    International Nuclear Information System (INIS)

    Stoch, H.; Dixon, K.

    1983-01-01

    The manual deals with various methods for a wide range of elemental analysis. Some of the methods that are used, include atomic absorption spectroscopy, optical emission spectroscopy and x-ray fluoresence spectroscopy. The basic charateristics of the method are given and the procedures are recorded step by step. One of the sections deals with methods associated with the recovery of uranium

  14. A Manual of Simplified Laboratory Methods for Operators of Wastewater Treatment Facilities.

    Science.gov (United States)

    Westerhold, Arnold F., Ed.; Bennett, Ernest C., Ed.

    This manual is designed to provide the small wastewater treatment plant operator, as well as the new or inexperienced operator, with simplified methods for laboratory analysis of water and wastewater. It is emphasized that this manual is not a replacement for standard methods but a guide for plants with insufficient equipment to perform analyses…

  15. Comparison of manual and automated quantification methods of {sup 123}I-ADAM

    Energy Technology Data Exchange (ETDEWEB)

    Kauppinen, T. [Helsinki Univ. Central Hospital (Finland). HUS Helsinki Medical Imaging Center; Helsinki Univ. Central Hospital (Finland). Division of Nuclear Medicine; Koskela, A.; Ahonen, A. [Helsinki Univ. Central Hospital (Finland). Division of Nuclear Medicine; Diemling, M. [Hermes Medical Solutions, Stockholm (Sweden); Keski-Rahkonen, A.; Sihvola, E. [Helsinki Univ. (Finland). Dept. of Public Health; Helsinki Univ. Central Hospital (Finland). Dept. of Psychiatry

    2005-07-01

    {sup 123}I-ADAM is a novel radioligand for imaging of the brain serotonin transporters (SERTs). Traditionally, the analysis of brain receptor studies has been based on observer-dependent manual region of interest definitions and visual interpretation. Our aim was to create a template for automated image registrations and volume of interest (VOI) quantification and to show that an automated quantification method of {sup 123}I-ADAM is more repeatable than the manual method. Patients, methods: A template and a predefined VOI map was created from {sup 123}I-ADAM scans done for healthy volunteers (n=15). Scans of another group of healthy persons (HS, n=12) and patients with bulimia nervosa (BN, n=10) were automatically fitted to the template and specific binding ratios (SBRs) were calculated by using the VOI map. Manual VOI definitions were done for the HS and BN groups by both one and two observers. The repeatability of the automated method was evaluated by using the BN group. Results: For the manual method, the interobserver coefficient of repeatability was 0.61 for the HS group and 1.00 for the BN group. The intra-observer coefficient of repeatability for the BN group was 0.70. For the automated method, the coefficient of repeatability was 0.13 for SBRs in midbrain. Conclusion: An automated quantification gives valuable information in addition to visual interpretation decreasing also the total image handling time and giving clear advantages for research work. An automated method for analysing {sup 123}I-ADAM binding to the brain SERT gives repeatable results for fitting the studies to the template and for calculating SBRs, and could therefore replace manual methods. (orig.)

  16. User's Manual for FEM-BEM Method. 1.0

    Science.gov (United States)

    Butler, Theresa; Deshpande, M. D. (Technical Monitor)

    2002-01-01

    A user's manual for using FORTRAN code to perform electromagnetic analysis of arbitrarily shaped material cylinders using a hybrid method that combines the finite element method (FEM) and the boundary element method (BEM). In this method, the material cylinder is enclosed by a fictitious boundary and the Maxwell's equations are solved by FEM inside the boundary and by BEM outside the boundary. The electromagnetic scattering on several arbitrarily shaped material cylinders using this FORTRAN code is computed to as examples.

  17. Manual method for dose calculation in gynecologic brachytherapy; Metodo manual para o calculo de doses em braquiterapia ginecologica

    Energy Technology Data Exchange (ETDEWEB)

    Vianello, Elizabeth A.; Almeida, Carlos E. de [Instituto Nacional do Cancer, Rio de Janeiro, RJ (Brazil); Biaggio, Maria F. de [Universidade do Estado, Rio de Janeiro, RJ (Brazil)

    1998-09-01

    This paper describes a manual method for dose calculation in brachytherapy of gynecological tumors, which allows the calculation of the doses at any plane or point of clinical interest. This method uses basic principles of vectorial algebra and the simulating orthogonal films taken from the patient with the applicators and dummy sources in place. The results obtained with method were compared with the values calculated with the values calculated with the treatment planning system model Theraplan and the agreement was better than 5% in most cases. The critical points associated with the final accuracy of the proposed method is related to the quality of the image and the appropriate selection of the magnification factors. This method is strongly recommended to the radiation oncology centers where are no treatment planning systems available and the dose calculations are manually done. (author) 10 refs., 5 figs.

  18. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    Energy Technology Data Exchange (ETDEWEB)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kim, Sam Soo [Kangwon National University College of Medicine, Neuroscience Research Institute, Kangwon (Korea); Kangwon National University Hospital, Department of Radiology, Kangwon-do (Korea)

    2008-07-15

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  19. Validation of hippocampal volumes measured using a manual method and two automated methods (FreeSurfer and IBASPM) in chronic major depressive disorder

    International Nuclear Information System (INIS)

    Tae, Woo Suk; Lee, Kang Uk; Nam, Eui-Cheol; Kim, Keun Woo; Kim, Sam Soo

    2008-01-01

    To validate the usefulness of the packages available for automated hippocampal volumetry, we measured hippocampal volumes using one manual and two recently developed automated volumetric methods. The study included T1-weighted magnetic resonance imaging (MRI) of 21 patients with chronic major depressive disorder (MDD) and 20 normal controls. Using coronal turbo field echo (TFE) MRI with a slice thickness of 1.3 mm, the hippocampal volumes were measured using three methods: manual volumetry, surface-based parcellation using FreeSurfer, and individual atlas-based volumetry using IBASPM. In addition, the intracranial cavity volume (ICV) was measured manually. The absolute left hippocampal volume of the patients with MDD measured using all three methods was significantly smaller than the left hippocampal volume of the normal controls (manual P=0.029, FreeSurfer P=0.035, IBASPM P=0.018). After controlling for the ICV, except for the right hippocampal volume measured using FreeSurfer, both measured hippocampal volumes of the patients with MDD were significantly smaller than the measured hippocampal volumes of the normal controls (right manual P=0.019, IBASPM P=0.012; left manual P=0.003, FreeSurfer P=0.010, IBASPM P=0.002). In the intrarater reliability test, the intraclass correlation coefficients (ICCs) were all excellent (manual right 0.947, left 0.934; FreeSurfer right 1.000, left 1.000; IBASPM right 1.000, left 1.000). In the test of agreement between the volumetric methods, the ICCs were right 0.846 and left 0.848 (manual and FreeSurfer), and right 0.654 and left 0.717 (manual and IBASPM). The automated hippocampal volumetric methods showed good agreement with manual hippocampal volumetry, but the volume measured using FreeSurfer was 35% larger and the agreement was questionable with IBASPM. Although the automated methods could detect hippocampal atrophy in the patients with MDD, the results indicate that manual hippocampal volumetry is still the gold standard

  20. ACARP Project C10059. ACARP manual of modern coal testing methods. Volume 1: The manual

    Energy Technology Data Exchange (ETDEWEB)

    Sakurovs, R.; Creelman, R.; Pohl, J.; Juniper, L. [CSIRO Energy Technology, Sydney, NSW (Australia)

    2002-07-01

    The Manual summarises the purpose, applicability, and limitations of a range of standard and modern coal testing methods that have potential to assist the coal company technologist to better evaluate coal performance. The first volume sets out the Modern Coal Testing Methods in summarised form that can be used as a quick guide to practitioners to assist in selecting the best technique to solve their problems.

  1. Yeast genetics. A manual of methods

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, J.F.T.; Spencer, D.M.; Bruce, I.J.

    1989-01-01

    This is a bench-top manual of methods needed both for classical genetics as related to yeasts, such as mating, sporulation, isolation of hybrids, microdissection of asci for the isolation of single-spore clones, as well as for mapping of genes and the construction of new strains by protoplast fusion. Special emphasis is on mutations in general, and on methods of isolating a number of important classes of mutants in particular. Basic techniques for the separation of chromosomes by electrophoresis, such as OFAGE, FIGE, and CHEF, are discussed, with detailed protocols for the first two. Furthermore, new methods, e.g. for the isolation of high molecular weight DNA from yeast, isolation of RNA, and techniques for transformation of yeasts, are also described in detail. (orig.) With 10 figs.

  2. ANSI/ASHRAE/IES Standard 90.1-2010 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-05-01

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1- 2010 (Standard 90.1-2010).The PRM is used for rating the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM. It should be noted that this document is created independently from ASHRAE and SSPC 90.1 and is not sanctioned nor approved by either of those entities . Potential users of this manual include energy modelers, software developers and implementers of “beyond code” energy programs. Energy modelers using ASHRAE Standard 90.1-2010 for beyond code programs can use this document as a reference manual for interpreting requirements of the Performance Rating method. Software developers, developing tools for automated creation of the baseline model can use this reference manual as a guideline for developing the rules for the baseline model.

  3. Comparison of Rice Direct Seeding Methods (Mechanical and Manual with Transplanting Method

    Directory of Open Access Journals (Sweden)

    A Eyvani

    2014-04-01

    Full Text Available The main method of rice planting in Iran is transplanting. Due to poor mechanization of rice production, this method is laborious and costly. The other method is direct seeding in wet lands which is performed in the one third of rice cultivation area of the world. The most important problem in this method is high labor requirement of weed control. In order to compare the different rice planting methods (direct drilling, transplanting, and seed broadcasting a manually operated rice direct seeder (drum seeder was designed and fabricated. The research was conducted using a randomized complete block design with three treatments and three replications. Required draft force, field efficiency, effective field capacity, yield, and yield components were measured and the treatments were compared economically. Results showed that there were significant differences among the treatments from the view point of rice yield at the confidence level of 95% i.e. the transplanting method had the maximum yield. A higher rice yield was obtained from the direct seeder compared to the manual broadcasting method but, the difference between these two methods for crop yield was not significant even at the confidence level of the 95%. The coefficient of variation of seed distribution with direct seeding was more than 20%. The labor and time requirements per hectare reduced to 7 and 20 times, respectively when comparing the newly designed direct seeder with the transplanting method. The direct seeding method had the highest benefit to cost ratio in spite of its lower yield. Therefore, this method could be recommended in the rice growing regions.

  4. Analytical methods manual for the Mineral Resource Surveys Program, U.S. Geological Survey

    Science.gov (United States)

    Arbogast, Belinda F.

    1996-01-01

    The analytical methods validated by the Mineral Resource Surveys Program, Geologic Division, is the subject of this manual. This edition replaces the methods portion of Open-File Report 90-668 published in 1990. Newer methods may be used which have been approved by the quality assurance (QA) project and are on file with the QA coordinator.This manual is intended primarily for use by laboratory scientists; this manual can also assist laboratory users to evaluate the data they receive. The analytical methods are written in a step by step approach so that they may be used as a training tool and provide detailed documentation of the procedures for quality assurance. A "Catalog of Services" is available for customer (submitter) use with brief listings of:the element(s)/species determined,method of determination,reference to cite,contact person,summary of the technique,and analyte concentration range.For a copy please contact the Branch office at (303) 236-1800 or fax (303) 236-3200.

  5. Outcome of manual hemorrhoidopexy in the management of hemorrhoids

    Directory of Open Access Journals (Sweden)

    Sujit Kumar

    2014-01-01

    Full Text Available Background: Manual hemorrhoidopexy is a new technique of treating second degree hemorrhoids. In contrast to the conventional resectional techniques (Milligan-Morgan, manual hemorrhoidopexy is a novel technique as described by T Carlo. It does not involve excision but plication with fixation of the prolapsing hemorrhoid. Objective: To study the outcome of manual hemorrhoidopexy and to compare manual hemorrhoidopexy with the traditional hemorrhoidectomy. Methods: This is a prospective study conducted over 16 months (January 2012 to April 2013 in the College of Medical Sciences Teaching Hospital (COMS-TH, Bharatpur, Chitwan, Department of Surgery. The patients who presented with third degree internal-hemorrhoids on a random basis, and underwent either conventional hemorrhoidectomy (Group A or Manual hemorrhoidopexy (Group B by senior consultant surgeons were included. The patients who had external hemorrhoids in addition to internal were excluded. Preoperative, intraoperative, and postoperative characteristics were evaluated. Results: Twenty five patients with median age group 42.5 years underwent conventional (Milligan-Morgan hemorrhoidectomy (Group A and 25 patients with mean age of 40.1 years underwent manual hemorrhoidopexy (Group B. Male patients were predominant in both groups. The patients in group A had more postoperative pain as compared to group B (as assessed by the visual analogue scale and requirement of post-operative analgesic and this was statistically significant (p<0.001. There was no significant difference among the other post-operative urinary retention. Twelve percent (n=3 patients in group A had post-operative bleeding and only 4% (n=1 in group B which was statistically significant (p<0.001. Mean duration of hospital stay in group A was 2.5 days as compared to 1.5 day in group B. Median follow up in both the study group was 3 (2-4 months. Conclusion: Manual hemorrhoidopexy has comparable outcomes in term of postoperative

  6. Endotracheal tube cuff pressure monitoring during neurosurgery - Manual vs. automatic method

    Directory of Open Access Journals (Sweden)

    Mukul Kumar Jain

    2011-01-01

    Full Text Available Background: Inflation and assessment of the endotracheal tube cuff pressure is often not appreciated as a critical aspect of endotracheal intubation. Appropriate endotracheal tube cuff pressure, endotracheal intubation seals the airway to prevent aspiration and provides for positive-pressure ventilation without air leak. Materials and Methods: Correlations between manual methods of assessing the pressure by an experienced anesthesiologists and assessment with maintenance of the pressure within the normal range by the automated pressure controller device were studied in 100 patients divided into two groups. In Group M, endotracheal tube cuff was inflated manually by a trained anesthesiologist and checked for its pressure hourly by cuff pressure monitor till the end of surgery. In Group C, endotracheal tube cuff was inflated by automated cuff pressure controller and pressure was maintained at 25-cm H 2 O throughout the surgeries. Repeated measure ANOVA was applied. Results: Repeated measure ANOVA results showed that average of endotracheal tube cuff pressure of 50 patients taken at seven different points is significantly different (F-value: 171.102, P-value: 0.000. Bonferroni correction test shows that average of endotracheal tube cuff pressure in all six groups are significantly different from constant group (P = 0.000. No case of laryngomalacia, tracheomalacia, tracheal stenosis, tracheoesophageal fistula or aspiration pneumonitis was observed. Conclusions: Endotracheal tube cuff pressure was significantly high when endotracheal tube cuff was inflated manually. The known complications of high endotracheal tube cuff pressure can be avoided if the cuff pressure controller device is used and manual methods cannot be relied upon for keeping the pressure within the recommended levels.

  7. The Alaska Commercial Fisheries Water Quality Sampling Methods and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Folley, G.; Pearson, L.; Crosby, C. [Alaska Dept. of Environmental Conservation, Soldotna, AK (United States); DeCola, E.; Robertson, T. [Nuka Research and Planning Group, Seldovia, AK (United States)

    2006-07-01

    A comprehensive water quality sampling program was conducted in response to the oil spill that occurred when the M/V Selendang Ayu ship ran aground near a major fishing port at Unalaska Island, Alaska in December 2004. In particular, the sampling program focused on the threat of spilled oil to the local commercial fisheries resources. Spill scientists were unable to confidently model the movement of oil away from the wreck because of limited oceanographic data. In order to determine which fish species were at risk of oil contamination, a real-time assessment of how and where the oil was moving was needed, because the wreck became a continual source of oil release for several weeks after the initial grounding. The newly developed methods and procedures used to detect whole oil during the sampling program will be presented in the Alaska Commercial Fisheries Water Quality Sampling Methods and Procedures Manual which is currently under development. The purpose of the manual is to provide instructions to spill managers while they try to determine where spilled oil has or has not been encountered. The manual will include a meaningful data set that can be analyzed in real time to assess oil movement and concentration. Sections on oil properties and processes will be included along with scientific water quality sampling methods for whole and dissolved phase oil to assess potential contamination of commercial fishery resources and gear in Alaska waters during an oil spill. The manual will present a general discussion of factors that should be considered when designing a sampling program after a spill. In order to implement Alaska's improved seafood safety measures, the spatial scope of spilled oil must be known. A water quality sampling program can provide state and federal fishery managers and food safety inspectors with important information as they identify at-risk fisheries. 11 refs., 7 figs.

  8. Comparison of manual & automated analysis methods for corneal endothelial cell density measurements by specular microscopy.

    Science.gov (United States)

    Huang, Jianyan; Maram, Jyotsna; Tepelus, Tudor C; Modak, Cristina; Marion, Ken; Sadda, SriniVas R; Chopra, Vikas; Lee, Olivia L

    2017-08-07

    To determine the reliability of corneal endothelial cell density (ECD) obtained by automated specular microscopy versus that of validated manual methods and factors that predict such reliability. Sharp central images from 94 control and 106 glaucomatous eyes were captured with Konan specular microscope NSP-9900. All images were analyzed by trained graders using Konan CellChek Software, employing the fully- and semi-automated methods as well as Center Method. Images with low cell count (input cells number <100) and/or guttata were compared with the Center and Flex-Center Methods. ECDs were compared and absolute error was used to assess variation. The effect on ECD of age, cell count, cell size, and cell size variation was evaluated. No significant difference was observed between the Center and Flex-Center Methods in corneas with guttata (p=0.48) or low ECD (p=0.11). No difference (p=0.32) was observed in ECD of normal controls <40 yrs old between the fully-automated method and manual Center Method. However, in older controls and glaucomatous eyes, ECD was overestimated by the fully-automated method (p=0.034) and semi-automated method (p=0.025) as compared to manual method. Our findings show that automated analysis significantly overestimates ECD in the eyes with high polymegathism and/or large cell size, compared to the manual method. Therefore, we discourage reliance upon the fully-automated method alone to perform specular microscopy analysis, particularly if an accurate ECD value is imperative. Copyright © 2017. Published by Elsevier España, S.L.U.

  9. Semiautomated segmentation of blood vessels using ellipse-overlap criteria: Method and comparison to manual editing

    International Nuclear Information System (INIS)

    Shiffman, Smadar; Rubin, Geoffrey D.; Schraedley-Desmond, Pamela; Napel, Sandy

    2003-01-01

    Two-dimensional intensity-based methods for the segmentation of blood vessels from computed-tomography-angiography data often result in spurious segments that originate from other objects whose intensity distributions overlap with those of the vessels. When segmented images include spurious segments, additional methods are required to select segments that belong to the target vessels. We describe a method that allows experts to select vessel segments from sequences of segmented images with little effort. Our method uses ellipse-overlap criteria to differentiate between segments that belong to different objects and are separated in plane but are connected in the through-plane direction. To validate our method, we used it to extract vessel regions from volumes that were segmented via analysis of isolabel-contour maps, and showed that the difference between the results of our method and manually-edited results was within inter-expert variability. Although the total editing duration for our method, which included user-interaction and computer processing, exceeded that of manual editing, the extent of user interaction required for our method was about a fifth of that required for manual editing

  10. Space shuttle/payload interface analysis. (Study 2.4) Volume 4: Business Risk and Value of Operations in Space (BRAVO). Part 2: User's manual

    Science.gov (United States)

    1974-01-01

    The BRAVO User's Manual is presented which describes the BRAVO methodology in terms of step-by-step procedures, so that it may be used as a tool for a team of analysts performing cost effectiveness analyses on potential future space applications. BRAVO requires a relatively general set of input information and a relatively small expenditure of resources. For Vol. 1, see N74-12493; for Vol. 2, see N74-14530.

  11. An evaluation of methods assessing the physical demands of manual lifting in scaffolding

    NARCIS (Netherlands)

    Beek, van der A.J.; Mathiassen, S.E.; Windhorst, J.; Burdorf, A.

    2005-01-01

    Four methods assessing the physical demands of manual lifting were compared. The scaffolding job was evaluated and three distinct scaffolding tasks were ranked using: (1) the revised NIOSH lifting equation (NIOSH method), (2) lifting guidelines for the Dutch construction industry (Arbouw method),

  12. Methods for the Determination of Chemical Contaminants in Drinking Water. Training Manual.

    Science.gov (United States)

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual, intended for chemists and technicians with little or no experience in chemical procedures required to monitor drinking water, covers analytical methods for inorganic and organic chemical contaminants listed in the interim primary drinking water regulations. Topics include methods for heavy metals, nitrate, and organic…

  13. CSTEM User Manual

    Science.gov (United States)

    Hartle, M.; McKnight, R. L.

    2000-01-01

    This manual is a combination of a user manual, theory manual, and programmer manual. The reader is assumed to have some previous exposure to the finite element method. This manual is written with the idea that the CSTEM (Coupled Structural Thermal Electromagnetic-Computer Code) user needs to have a basic understanding of what the code is actually doing in order to properly use the code. For that reason, the underlying theory and methods used in the code are described to a basic level of detail. The manual gives an overview of the CSTEM code: how the code came into existence, a basic description of what the code does, and the order in which it happens (a flowchart). Appendices provide a listing and very brief description of every file used by the CSTEM code, including the type of file it is, what routine regularly accesses the file, and what routine opens the file, as well as special features included in CSTEM.

  14. Massage, reflexology and other manual methods for pain management in labour.

    Science.gov (United States)

    Smith, Caroline A; Levett, Kate M; Collins, Carmel T; Dahlen, Hannah G; Ee, Carolyn C; Suganuma, Machiko

    2018-03-28

    Many women would like to avoid pharmacological or invasive methods of pain management in labour, and this may contribute towards the popularity of complementary methods of pain management. This review examined the evidence currently available on manual methods, including massage and reflexology, for pain management in labour. This review is an update of the review first published in 2012. To assess the effect, safety and acceptability of massage, reflexology and other manual methods to manage pain in labour. For this update, we searched Cochrane Pregnancy and Childbirth's Trials Register (30 June 2017), the Cochrane Central Register of Controlled Trials (CENTRAL; 2017, Issue 6), MEDLINE (1966 to 30 June 2017, CINAHL (1980 to 30 June 2017), the Australian New Zealand Clinical Trials Registry (4 August 2017), Chinese Clinical Trial Registry (4 August 2017), ClinicalTrials.gov, (4 August 2017), the National Center for Complementary and Integrative Health (4 August 2017), the WHO International Clinical Trials Registry Platform (ICTRP) (4 August 2017) and reference lists of retrieved trials. We included randomised controlled trials comparing manual methods with standard care, other non-pharmacological forms of pain management in labour, no treatment or placebo. We searched for trials of the following modalities: massage, warm packs, thermal manual methods, reflexology, chiropractic, osteopathy, musculo-skeletal manipulation, deep tissue massage, neuro-muscular therapy, shiatsu, tuina, trigger point therapy, myotherapy and zero balancing. We excluded trials for pain management relating to hypnosis, aromatherapy, acupuncture and acupressure; these are included in other Cochrane reviews. Two review authors independently assessed trial quality, extracted data and checked data for accuracy. We contacted trial authors for additional information. We assessed the quality of the evidence using the GRADE approach. We included a total of 14 trials; 10 of these (1055 women

  15. EDAS-manual. SATAN - system to analyze tremendous amounts of nuclear data. Vol. 2

    International Nuclear Information System (INIS)

    Goeringer, H.; Gralla, S.; Malzacher, P.; Richter, M.; Schall, D.; Winkelmann, K.

    1988-09-01

    The system to analyze tremendous amounts of nuclear data (SATAN) shows different steps of a special experiment data evaluation called 'Linearisation'. The report contains the EDAS-manual with EDAS-command, TSO-command, macro and procedure. Syntax and usage of EDAS macros are explained. (DG)

  16. A unique manual method for emergency offsite dose calculations

    International Nuclear Information System (INIS)

    Wildner, T.E.; Carson, B.H.; Shank, K.E.

    1987-01-01

    This paper describes a manual method developed for performance of emergency offsite dose calculations for PP and L's Susquehanna Steam Electric Station. The method is based on a three-part carbonless form. The front page guides the user through selection of the appropriate accident case and inclusion of meteorological and effluent data data. By circling the applicable accident descriptors, the user circles the dose factors on pages 2 and 3 which are then simply multiplied to yield the whole body and thyroid dose rates at the plant boundary, two, five, and ten miles. The process used to generate the worksheet is discussed, including the method used to incorporate the observed terrain effects on airflow patterns caused by the Susquehanna River Valley topography

  17. Advances in boundary elements. Vol. 1-3

    International Nuclear Information System (INIS)

    Brebbia, C.A.; Connor, J.J.

    1989-01-01

    This book contains some of the edited papers presented at the 11th Boundary Element Conference, held in Cambridge, Massachusetts, during August 1989. The papers are arranged in three different books comprising the following topics: Vol. 1: Computations and Fundamentals - comprises sections on fundamentals, adaptive techniques, error and convergence, numerical methods and computational aspects. (283 p.). Vol. 2: Field and fluid flow solutions - includes the following topics: potential problems, thermal studies, electrical and electromagnetic problems, wave propagation, acoustics and fluid flow. (484 p.). Vol. 3: Stress analysis - deals with advances in linear problems, nonlinear problems, fracture mechanics, contact mechanics, optimization, geomechanics, plates and shells, vibrations and industrial applications. (450 p). (orig./HP)

  18. SRC-I demonstration plant analytical laboratory methods manual. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Klusaritz, M.L.; Tewari, K.C.; Tiedge, W.F.; Skinner, R.W.; Znaimer, S.

    1983-03-01

    This manual is a compilation of analytical procedures required for operation of a Solvent-Refined Coal (SRC-I) demonstration or commercial plant. Each method reproduced in full includes a detailed procedure, a list of equipment and reagents, safety precautions, and, where possible, a precision statement. Procedures for the laboratory's environmental and industrial hygiene modules are not included. Required American Society for Testing and Materials (ASTM) methods are cited, and ICRC's suggested modifications to these methods for handling coal-derived products are provided.

  19. ANSI/ASHRAE/IES Standard 90.1-2016 Performance Rating Method Reference Manual

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Supriya [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Rosenberg, Michael I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Eley, Charles [Eley and Associates, Hobe Sound, FL (United States)

    2017-09-29

    This document is intended to be a reference manual for the Appendix G Performance Rating Method (PRM) of ANSI/ASHRAE/IES Standard 90.1-2016 (Standard 90.1-2016). The PRM can be used to demonstrate compliance with the standard and to rate the energy efficiency of commercial and high-rise residential buildings with designs that exceed the requirements of Standard 90.1. Use of the PRM for demonstrating compliance with Standard 90.1 is a new feature of the 2016 edition. The procedures and processes described in this manual are designed to provide consistency and accuracy by filling in gaps and providing additional details needed by users of the PRM.

  20. Manual herbicide application methods for managing vegetation in Appalachian hardwood forests

    Science.gov (United States)

    Jeffrey D. Kochenderfer; James N. Kochenderfer; Gary W. Miller

    2012-01-01

    Four manual herbicide application methods are described for use in Appalachian hardwood forests. Stem injection, basal spray, cut-stump, and foliar spray techniques can be used to control interfering vegetation and promote the development of desirable reproduction and valuable crop trees in hardwood forests. Guidelines are presented to help the user select the...

  1. Manual of analytical methods for the Industrial Hygiene Chemistry Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Greulich, K.A.; Gray, C.E. (comp.)

    1991-08-01

    This Manual is compiled from techniques used in the Industrial Hygiene Chemistry Laboratory of Sandia National Laboratories in Albuquerque, New Mexico. The procedures are similar to those used in other laboratories devoted to industrial hygiene practices. Some of the methods are standard; some, modified to suit our needs; and still others, developed at Sandia. The authors have attempted to present all methods in a simple and concise manner but in sufficient detail to make them readily usable. It is not to be inferred that these methods are universal for any type of sample, but they have been found very reliable for the types of samples mentioned.

  2. Manual of analytical methods for the Industrial Hygiene Chemistry Laboratory

    International Nuclear Information System (INIS)

    Greulich, K.A.; Gray, C.E.

    1991-08-01

    This Manual is compiled from techniques used in the Industrial Hygiene Chemistry Laboratory of Sandia National Laboratories in Albuquerque, New Mexico. The procedures are similar to those used in other laboratories devoted to industrial hygiene practices. Some of the methods are standard; some, modified to suit our needs; and still others, developed at Sandia. The authors have attempted to present all methods in a simple and concise manner but in sufficient detail to make them readily usable. It is not to be inferred that these methods are universal for any type of sample, but they have been found very reliable for the types of samples mentioned

  3. Solutions manual to accompany An introduction to numerical methods and analysis

    CERN Document Server

    Epperson, James F

    2014-01-01

    A solutions manual to accompany An Introduction to Numerical Methods and Analysis, Second Edition An Introduction to Numerical Methods and Analysis, Second Edition reflects the latest trends in the field, includes new material and revised exercises, and offers a unique emphasis on applications. The author clearly explains how to both construct and evaluate approximations for accuracy and performance, which are key skills in a variety of fields. A wide range of higher-level methods and solutions, including new topics such as the roots of polynomials, sp

  4. The impact of type of manual medication cart filling method on the frequency of medication administration errors : A prospective before and after study

    NARCIS (Netherlands)

    Schimmel, Anneliene M.; Becker, Matthijs L.; van den Bout, Tilly; Taxis, Katja; van den Bemt, Patricia M. L. A.

    Background: The medication cart can be filled using an automated system or a manual method and when using a manual method the medication can be arranged either by round time or by medication name. For the manual methods, it is hypothesized that the latter method would result in a lower frequency of

  5. Ground Snow Measurements: Comparisons of the Hotplate, Weighing and Manual Methods

    Science.gov (United States)

    Wettlaufer, A.; Snider, J.; Campbell, L. S.; Steenburgh, W. J.; Burkhart, M.

    2015-12-01

    The Yankee Environmental Systems (YES) Hotplate was developed to avoid some of the problems associated with weighing snowfall sensors. This work compares Hotplate, weighing sensor (ETI NOAH-II) and manual measurements of liquid-equivalent depth. The main field site was at low altitude in western New York; Hotplate and ETI comparisons were also made at two forested subalpine sites in southeastern Wyoming. The manual measurement (only conducted at the New York site) was derived by weighing snow cores sampled from a snow board. The two recording gauges (Hotplate and ETI) were located within 5 m of the snow board. Hotplate-derived accumulations were corrected using a wind-speed dependent catch efficiency and the ETI orifice was heated and alter shielded. Three important findings are evident from the comparisons: 1) The Yes-derived accumulations, recorded in a user-accessible file, were compared to accumulations derived using an in-house calibration and fundamental measurements (plate power, long and shortwave radiances, wind speed, and temperature). These accumulations are highly correlated (N=24; r2=0.99), but the YES-derived values are larger by 20%. 2) The in-house Hotplate accumulations are in good agreement with ETI-based accumulations but with larger variability (N=24; r2=0.88). 3) The comparison of in-house Hotplate accumulation versus manual accumulation, expressed as mm of liquid, exhibits a fitted linear relationship Y (in-house) versus X (manual) given by Y = -0.2 (±1.4) + 0.9 (±0.1) · X (N= 20; r2=0.89). Thus, these two methods agree within statistical uncertainty.

  6. [Comparison of manual and automated (MagNA Pure) nucleic acid isolation methods in molecular diagnosis of HIV infections].

    Science.gov (United States)

    Alp, Alpaslan; Us, Dürdal; Hasçelik, Gülşen

    2004-01-01

    Rapid quantitative molecular methods are very important for the diagnosis of human immunodeficiency virus (HIV) infections, assessment of prognosis and follow up. The purpose of this study was to compare and evaluate the performances of conventional manual extraction method and automated MagNA Pure system, for the nucleic acid isolation step which is the first and most important step in molecular diagnosis of HIV infections. Plasma samples of 35 patients in which anti-HIV antibodies were found as positive by microparticule enzyme immunoassay and confirmed by immunoblotting method, were included in the study. The nucleic acids obtained simultaneously by manual isolation kit (Cobas Amplicor, HIV-1 Monitor Test, version 1.5, Roche Diagnostics) and automated system (MagNA Pure LC Total Nucleic Acid Isolation Kit, Roche Diagnostics), were amplified and detected in Cobas Amplicor (Roche Diagnostics) instrument. Twenty three of 35 samples (65.7%) were found to be positive, and 9 (25.7%) were negative by both of the methods. The agreement between the methods were detected as 91.4%, for qualitative results. Viral RNA copies detected by manual and MagNA Pure isolation methods were found between 76.0-7.590.000 (mean: 487.143) and 113.0-20.300.0000 (mean: 2.174.097) copies/ml, respectively. When both of the overall and individual results were evaluated, the number of RNA copies obtained with automatized system, were found higher than the manual method (p<0.05). Three samples which had low numbers of nucleic acids (113, 773, 857, respectively) with MagNA Pure, yielded negative results with manual method. In conclusion, the automatized MagNA Pure system was found to be a reliable, rapid and practical method for the isolation of HIV-RNA.

  7. Vol draadwerk

    African Journals Online (AJOL)

    Owner

    Die motto van Marius Crous se derde bundel,. Vol draadwerk (2012) is ontleen aan die vader van die psigoanalise, Sigmund Freud, wat lui: “Everywhere I go I find a poet has been there before me.” Vol draadwerk verskyn ses jaar ná sy vorige bundel, Aan 'n beentjie sit en kluif. (2006). Vir sy bundel, Brief uit die kolonies ...

  8. Continuous Manual Exchange Transfusion for Patients with Sickle Cell Disease: An Efficient Method to Avoid Iron Overload.

    Science.gov (United States)

    Koehl, Bérengère; Missud, Florence; Holvoet, Laurent; Ithier, Ghislaine; Sakalian-Black, Oliver; Haouari, Zinedine; Lesprit, Emmanuelle; Baruchel, André; Benkerrou, Malika

    2017-03-14

    Children with sickle cell anemia (SCA) may be at risk of cerebral vasculopathy and strokes, which can be prevented by chronic transfusion programs. Repeated transfusions of packed red blood cells (PRBCs) is currently the simplest and most used technique for chronic transfusion programs. However, iron overload is one of the major side effects of this therapy. More developed methods exist, notably the apheresis of RBC (erythrapheresis), which is currently the safest and most efficient method. However, it is costly, complicated, and cannot be implemented everywhere, nor is it suitable for all patients. Manual exchange transfusions combine one or more manual phlebotomies with a PRBC transfusion. At the Reference Center of Sickle Cell Disease, we set up a continuous method of manual exchange transfusion that is feasible for all hospital settings, demands no specific equipment, and is widely applicable. In terms of HbS decrease, stroke prevention, and iron overload prevention, this method showed comparable efficiency to erythrapheresis. In cases where erythrapheresis is not available, this method can be a good alternative for patients and care centers.

  9. MARS code manual volume I: code structure, system models, and solution methods

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Kim, Kyung Doo; Bae, Sung Won; Jeong, Jae Jun; Lee, Seung Wook; Hwang, Moon Kyu; Yoon, Churl

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This theory manual provides a complete list of overall information of code structure and major function of MARS including code architecture, hydrodynamic model, heat structure, trip / control system and point reactor kinetics model. Therefore, this report would be very useful for the code users. The overall structure of the manual is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  10. HVAC system operation manual of IMEF

    International Nuclear Information System (INIS)

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun.

    1997-06-01

    This manual is operation procedures of the IMEF(Irradiated Material Examination Facility) HVAC(Heating, Ventilation and Air Conditioning) System. General operation procedures and test method of the IMEF HVAC system are described. The manual is as follows; 1. HVAC system operation manual 2. HVAC system management guide 3. HVAC system maintenance manual 4. HVAC system air velocity and flowrate measurement manual 5. HVAC system HEPA filter leak test manual 6. HVAC system charcoal filter leak test manual 7. HVAC system HEPA and charcoal filter exchange manual. (author). 8 tabs

  11. EML procedures manual

    International Nuclear Information System (INIS)

    Volchok, H.L.; de Planque, G.

    1982-01-01

    This manual contains the procedures that are used currently by the Environmental Measurements Laboratory of the US Department of Energy. In addition a number of analytical methods from other laboratories have been included. These were tested for reliability at the Battelle, Pacific Northwest Laboratory under contract with the Division of Biomedical and Environmental Research of the AEC. These methods are clearly distinguished. The manual is prepared in loose leaf form to facilitate revision of the procedures and inclusion of additional procedures or data sheets. Anyone receiving the manual through EML should receive this additional material automatically. The contents are as follows: (1) general; (2) sampling; (3) field measurements; (4) general analytical chemistry; (5) chemical procedures; (6) data section; (7) specifications

  12. Cervical spine motion in manual versus Jackson table turning methods in a cadaveric global instability model.

    Science.gov (United States)

    DiPaola, Matthew J; DiPaola, Christian P; Conrad, Bryan P; Horodyski, MaryBeth; Del Rossi, Gianluca; Sawers, Andrew; Bloch, David; Rechtine, Glenn R

    2008-06-01

    A study of spine biomechanics in a cadaver model. To quantify motion in multiple axes created by transfer methods from stretcher to operating table in the prone position in a cervical global instability model. Patients with an unstable cervical spine remain at high risk for further secondary injury until their spine is adequately surgically stabilized. Previous studies have revealed that collars have significant, but limited benefit in preventing cervical motion when manually transferring patients. The literature proposes multiple methods of patient transfer, although no one method has been universally adopted. To date, no study has effectively evaluated the relationship between spine motion and various patient transfer methods to an operating room table for prone positioning. A global instability was surgically created at C5-6 in 4 fresh cadavers with no history of spine pathology. All cadavers were tested both with and without a rigid cervical collar in the intact and unstable state. Three headrest permutations were evaluated Mayfield (SM USA Inc), Prone View (Dupaco, Oceanside, CA), and Foam Pillow (OSI, Union City, CA). A trained group of medical staff performed each of 2 transfer methods: the "manual" and the "Jackson table" transfer. The manual technique entailed performing a standard rotation of the supine patient on a stretcher to the prone position on the operating room table with in-line manual cervical stabilization. The "Jackson" technique involved sliding the supine patient to the Jackson table (OSI, Union City, CA) with manual in-line cervical stabilization, securing them to the table, then initiating the table's lock and turn mechanism and rotating them into a prone position. An electromagnetic tracking device captured angular motion between the C5 and C6 vertebral segments. Repeated measures statistical analysis was performed to evaluate the following conditions: collar use (2 levels), headrest (3 levels), and turning technique (2 levels). For all

  13. Validity of a Manual Soft Tissue Profile Prediction Method Following Mandibular Setback Osteotomy

    OpenAIRE

    Kolokitha, Olga-Elpis

    2007-01-01

    Objectives The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. Methods To test the validity of the manu...

  14. VARIABILITY OF MANUAL AND COMPUTERIZED METHODS FOR MEASURING CORONAL VERTEBRAL INCLINATION IN COMPUTED TOMOGRAPHY IMAGES

    Directory of Open Access Journals (Sweden)

    Tomaž Vrtovec

    2015-06-01

    Full Text Available Objective measurement of coronal vertebral inclination (CVI is of significant importance for evaluating spinal deformities in the coronal plane. The purpose of this study is to systematically analyze and compare manual and computerized measurements of CVI in cross-sectional and volumetric computed tomography (CT images. Three observers independently measured CVI in 14 CT images of normal and 14 CT images of scoliotic vertebrae by using six manual and two computerized measurements. Manual measurements were obtained in coronal cross-sections by manually identifying the vertebral body corners, which served to measure CVI according to the superior and inferior tangents, left and right tangents, and mid-endplate and mid-wall lines. Computerized measurements were obtained in two dimensions (2D and in three dimensions (3D by manually initializing an automated method in vertebral centroids and then searching for the planes of maximal symmetry of vertebral anatomical structures. The mid-endplate lines were the most reproducible and reliable manual measurements (intra- and inter-observer variability of 0.7° and 1.2° standard deviation, SD, respectively. The computerized measurements in 3D were more reproducible and reliable (intra- and inter-observer variability of 0.5° and 0.7° SD, respectively, but were most consistent with the mid-wall lines (2.0° SD and 1.4° mean absolute difference. The manual CVI measurements based on mid-endplate lines and the computerized CVI measurements in 3D resulted in the lowest intra-observer and inter-observer variability, however, computerized CVI measurements reduce observer interaction.

  15. ACARP Project C10059. ACARP manual of modern coal testing methods. Volume 2: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Sakurovs, R.; Creelman, R.; Pohl, J.; Juniper, L. [CSIRO Energy Technology, Sydney, NSW (Australia)

    2002-07-01

    The Manual summarises the purpose, applicability, and limitations of a range of standard and modern coal testing methods that have potential to assist the coal company technologist to better evaluate coal performance. It is presented in two volumes. This second volume provides more detailed information regarding the methods discussed in Volume 1.

  16. Simple heuristics: A bridge between manual core design and automated optimization methods

    International Nuclear Information System (INIS)

    White, J.R.; Delmolino, P.M.

    1993-01-01

    The primary function of RESCUE is to serve as an aid in the analysis and identification of feasible loading patterns for LWR reload cores. The unique feature of RESCUE is that its physics model is based on some recent advances in generalized perturbation theory (GPT) methods. The high order GPT techniques offer the accuracy, computational efficiency, and flexibility needed for the implementation of a full range of capabilities within a set of compatible interactive (manual and semi-automated) and automated design tools. The basic design philosophy and current features within RESCUE are reviewed, and the new semi-automated capability is highlighted. The online advisor facility appears quite promising and it provides a natural bridge between the traditional trial-and-error manual process and the recent progress towards fully automated optimization sequences. (orig.)

  17. Clusters in Nuclei. Vol. 2

    International Nuclear Information System (INIS)

    Beck, Christian

    2012-01-01

    Following the pioneering discovery of alpha clustering and of molecular resonances, the field of nuclear clustering is today one of those domains of heavy-ion nuclear physics that faces the greatest challenges, yet also contains the greatest opportunities. After many summer schools and workshops, in particular over the last decade, the community of nuclear molecular physicists has decided to collaborate in producing a comprehensive collection of lectures and tutorial reviews covering the field. This second volume follows the successful Lect. Notes Phys. 818 (Vol.1), and comprises six extensive lectures covering the following topics: - Microscopic cluster models - Neutron halo and break-up reactions - Break-up reaction models for two- and three-cluster projectiles - Clustering effects within the di-nuclear model - Nuclear alpha-particle condensates - Clusters in nuclei: experimental perspectives By promoting new ideas and developments while retaining a pedagogical style of presentation throughout, these lectures will serve as both a reference and an advanced teaching manual for future courses and schools in the fields of nuclear physics and nuclear astrophysics. (orig.)

  18. Clusters in Nuclei. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Beck, Christian (ed.) [Strasbourg Univ. (France). Inst. Pluridiciplinaire Hubert Curien

    2012-07-01

    Following the pioneering discovery of alpha clustering and of molecular resonances, the field of nuclear clustering is today one of those domains of heavy-ion nuclear physics that faces the greatest challenges, yet also contains the greatest opportunities. After many summer schools and workshops, in particular over the last decade, the community of nuclear molecular physicists has decided to collaborate in producing a comprehensive collection of lectures and tutorial reviews covering the field. This second volume follows the successful Lect. Notes Phys. 818 (Vol.1), and comprises six extensive lectures covering the following topics: - Microscopic cluster models - Neutron halo and break-up reactions - Break-up reaction models for two- and three-cluster projectiles - Clustering effects within the di-nuclear model - Nuclear alpha-particle condensates - Clusters in nuclei: experimental perspectives By promoting new ideas and developments while retaining a pedagogical style of presentation throughout, these lectures will serve as both a reference and an advanced teaching manual for future courses and schools in the fields of nuclear physics and nuclear astrophysics. (orig.)

  19. No-cost manual method for preparation of tissue microarrays having high quality comparable to semiautomated methods.

    Science.gov (United States)

    Foda, Abd Al-Rahman Mohammad

    2013-05-01

    Manual tissue microarray (TMA) construction had been introduced to avoid the high cost of automated and semiautomated techniques. The cheapest and simplest technique for constructing manual TMA was that of using mechanical pencil tips. This study was carried out to modify this method, aiming to raise its quality to reach that of expensive ones. Some modifications were introduced to Shebl's technique. Two conventional mechanical pencil tips of different diameters were used to construct the recipient blocks. A source of mild heat was used, and blocks were incubated at 38°C overnight. With our modifications, 3 high-density TMA blocks were constructed. We successfully performed immunostaining without substantial tissue loss. Our modifications increased the number of cores per block and improved the stability of the cores within the paraffin block. This new, modified technique is a good alternative for expensive machines in many laboratories.

  20. A Kinematic Study of Prosodic Structure in Articulatory and Manual Gestures: Results from a Novel Method of Data Collection

    Directory of Open Access Journals (Sweden)

    Jelena Krivokapić

    2017-03-01

    Full Text Available The primary goal of this work is to examine prosodic structure as expressed concurrently through articulatory and manual gestures. Specifically, we investigated the effects of phrase-level prominence (Experiment 1 and of prosodic boundaries (Experiments 2 and 3 on the kinematic properties of oral constriction and manual gestures. The hypothesis guiding this work is that prosodic structure will be similarly expressed in both modalities. To test this, we have developed a novel method of data collection that simultaneously records speech audio, vocal tract gestures (using electromagnetic articulometry and manual gestures (using motion capture. This method allows us, for the first time, to investigate kinematic properties of body movement and vocal tract gestures simultaneously, which in turn allows us to examine the relationship between speech and body gestures with great precision. A second goal of the paper is thus to establish the validity of this method. Results from two speakers show that manual and oral gestures lengthen under prominence and at prosodic boundaries, indicating that the effects of prosodic structure extend beyond the vocal tract to include body movement.1

  1. nijotech vol. 8. no. 1 september 1984 achi 41 the design of a manual

    African Journals Online (AJOL)

    Dr Obe

    1984-09-01

    Sep 1, 1984 ... drives. This design enables the manual selection of the axis to be driven and the axis displacement after which motion on the axis is automatically halted. Using this design a machine resolution. (accuracy) of 0.00254mm (0.0001 in) was achieved on the machine tool used in this investigation. NOTATION.

  2. A comparison of coronal mass ejections identified by manual and automatic methods

    Directory of Open Access Journals (Sweden)

    S. Yashiro

    2008-10-01

    Full Text Available Coronal mass ejections (CMEs are related to many phenomena (e.g. flares, solar energetic particles, geomagnetic storms, thus compiling of event catalogs is important for a global understanding these phenomena. CMEs have been identified manually for a long time, but in the SOHO era, automatic identification methods are being developed. In order to clarify the advantage and disadvantage of the manual and automatic CME catalogs, we examined the distributions of CME properties listed in the CDAW (manual and CACTus (automatic catalogs. Both catalogs have a good agreement on the wide CMEs (width>120° in their properties, while there is a significant discrepancy on the narrow CMEs (width≤30°: CACTus has a larger number of narrow CMEs than CDAW. We carried out an event-by-event examination of a sample of events and found that the CDAW catalog have missed many narrow CMEs during the solar maximum. Another significant discrepancy was found on the fast CMEs (speed>1000 km/s: the majority of the fast CDAW CMEs are wide and originate from low latitudes, while the fast CACTus CMEs are narrow and originate from all latitudes. Event-by-event examination of a sample of events suggests that CACTus has a problem on the detection of the fast CMEs.

  3. Comparison of Particulate Mercury Measured with Manual and Automated Methods

    Directory of Open Access Journals (Sweden)

    Rachel Russo

    2011-01-01

    Full Text Available A study was conducted to compare measuring particulate mercury (HgP with the manual filter method and the automated Tekran system. Simultaneous measurements were conducted with the Tekran and Teflon filter methodologies in the marine and coastal continental atmospheres. Overall, the filter HgP values were on the average 21% higher than the Tekran HgP, and >85% of the data were outside of ±25% region surrounding the 1:1 line. In some cases the filter values were as much as 3-fold greater, with

  4. Registration of T2-weighted and diffusion-weighted MR images of the prostate: comparison between manual and landmark-based methods

    Science.gov (United States)

    Peng, Yahui; Jiang, Yulei; Soylu, Fatma N.; Tomek, Mark; Sensakovic, William; Oto, Aytekin

    2012-02-01

    Quantitative analysis of multi-parametric magnetic resonance (MR) images of the prostate, including T2-weighted (T2w) and diffusion-weighted (DW) images, requires accurate image registration. We compared two registration methods between T2w and DW images. We collected pre-operative MR images of 124 prostate cancer patients (68 patients scanned with a GE scanner and 56 with Philips scanners). A landmark-based rigid registration was done based on six prostate landmarks in both T2w and DW images identified by a radiologist. Independently, a researcher manually registered the same images. A radiologist visually evaluated the registration results by using a 5-point ordinal scale of 1 (worst) to 5 (best). The Wilcoxon signed-rank test was used to determine whether the radiologist's ratings of the results of the two registration methods were significantly different. Results demonstrated that both methods were accurate: the average ratings were 4.2, 3.3, and 3.8 for GE, Philips, and all images, respectively, for the landmark-based method; and 4.6, 3.7, and 4.2, respectively, for the manual method. The manual registration results were more accurate than the landmark-based registration results (p < 0.0001 for GE, Philips, and all images). Therefore, the manual method produces more accurate registration between T2w and DW images than the landmark-based method.

  5. Hippocampal volume change measurement: quantitative assessment of the reproducibility of expert manual outlining and the automated methods FreeSurfer and FIRST.

    Science.gov (United States)

    Mulder, Emma R; de Jong, Remko A; Knol, Dirk L; van Schijndel, Ronald A; Cover, Keith S; Visser, Pieter J; Barkhof, Frederik; Vrenken, Hugo

    2014-05-15

    To measure hippocampal volume change in Alzheimer's disease (AD) or mild cognitive impairment (MCI), expert manual delineation is often used because of its supposed accuracy. It has been suggested that expert outlining yields poorer reproducibility as compared to automated methods, but this has not been investigated. To determine the reproducibilities of expert manual outlining and two common automated methods for measuring hippocampal atrophy rates in healthy aging, MCI and AD. From the Alzheimer's Disease Neuroimaging Initiative (ADNI), 80 subjects were selected: 20 patients with AD, 40 patients with mild cognitive impairment (MCI) and 20 healthy controls (HCs). Left and right hippocampal volume change between baseline and month-12 visit was assessed by using expert manual delineation, and by the automated software packages FreeSurfer (longitudinal processing stream) and FIRST. To assess reproducibility of the measured hippocampal volume change, both back-to-back (BTB) MPRAGE scans available for each visit were analyzed. Hippocampal volume change was expressed in μL, and as a percentage of baseline volume. Reproducibility of the 1-year hippocampal volume change was estimated from the BTB measurements by using linear mixed model to calculate the limits of agreement (LoA) of each method, reflecting its measurement uncertainty. Using the delta method, approximate p-values were calculated for the pairwise comparisons between methods. Statistical analyses were performed both with inclusion and exclusion of visibly incorrect segmentations. Visibly incorrect automated segmentation in either one or both scans of a longitudinal scan pair occurred in 7.5% of the hippocampi for FreeSurfer and in 6.9% of the hippocampi for FIRST. After excluding these failed cases, reproducibility analysis for 1-year percentage volume change yielded LoA of ±7.2% for FreeSurfer, ±9.7% for expert manual delineation, and ±10.0% for FIRST. Methods ranked the same for reproducibility of 1

  6. Myocardial infarct sizing by late gadolinium-enhanced MRI: Comparison of manual, full-width at half-maximum, and n-standard deviation methods.

    Science.gov (United States)

    Zhang, Lin; Huttin, Olivier; Marie, Pierre-Yves; Felblinger, Jacques; Beaumont, Marine; Chillou, Christian DE; Girerd, Nicolas; Mandry, Damien

    2016-11-01

    To compare three widely used methods for myocardial infarct (MI) sizing on late gadolinium-enhanced (LGE) magnetic resonance (MR) images: manual delineation and two semiautomated techniques (full-width at half-maximum [FWHM] and n-standard deviation [SD]). 3T phase-sensitive inversion-recovery (PSIR) LGE images of 114 patients after an acute MI (2-4 days and 6 months) were analyzed by two independent observers to determine both total and core infarct sizes (TIS/CIS). Manual delineation served as the reference for determination of optimal thresholds for semiautomated methods after thresholding at multiple values. Reproducibility and accuracy were expressed as overall bias ± 95% limits of agreement. Mean infarct sizes by manual methods were 39.0%/24.4% for the acute MI group (TIS/CIS) and 29.7%/17.3% for the chronic MI group. The optimal thresholds (ie, providing the closest mean value to the manual method) were FWHM30% and 3SD for the TIS measurement and FWHM45% and 6SD for the CIS measurement (paired t-test; all P > 0.05). The best reproducibility was obtained using FWHM. For TIS measurement in the acute MI group, intra-/interobserver agreements, from Bland-Altman analysis, with FWHM30%, 3SD, and manual were -0.02 ± 7.74%/-0.74 ± 5.52%, 0.31 ± 9.78%/2.96 ± 16.62% and -2.12 ± 8.86%/0.18 ± 16.12, respectively; in the chronic MI group, the corresponding values were 0.23 ± 3.5%/-2.28 ± 15.06, -0.29 ± 10.46%/3.12 ± 13.06% and 1.68 ± 6.52%/-2.88 ± 9.62%, respectively. A similar trend for reproducibility was obtained for CIS measurement. However, semiautomated methods produced inconsistent results (variabilities of 24-46%) compared to manual delineation. The FWHM technique was the most reproducible method for infarct sizing both in acute and chronic MI. However, both FWHM and n-SD methods showed limited accuracy compared to manual delineation. J. Magn. Reson. Imaging 2016;44:1206-1217. © 2016 International Society for Magnetic Resonance in Medicine.

  7. FINAS. Example manual. 2

    International Nuclear Information System (INIS)

    Iwata, Koji; Tsukimori, Kazuyuki; Ueno, Mutsuo

    2003-12-01

    FINAS is a general purpose structural analysis computer program which was developed by Japan Nuclear Cycle Development Institute for the analysis of static, dynamic and thermal responses of elastic and inelastic structures by the finite element method. This manual contains typical analysis examples that illustrate applications of FINAS to a variety of structural engineering problems. The first part of this manual presents fundamental examples in which numerical solutions by FINAS are compared with some analytical reference solutions, and the second part of this manual presents more complex examples intended for practical application. All the input data images and principal results for each problem are included in this manual for beginners' convenience. All the analyses are performed by using the FINAS Version 13.0. (author)

  8. Procedure manual for the estimation of average indoor radon-daughter concentrations using the filtered alpha-track method

    International Nuclear Information System (INIS)

    George, J.L.

    1988-04-01

    One of the measurement needs of US Department of Energy (DOE) remedial action programs is the estimation of the annual-average indoor radon-daughter concentration (RDC) in structures. The filtered alpha-track method, using a 1-year exposure period, can be used to accomplish RDC estimations for the DOE remedial action programs. This manual describes the procedure used to obtain filtered alpha-track measurements to derive average RDC estimates from the measurrements. Appropriate quality-assurance and quality-control programs are also presented. The ''prompt'' alpha-track method of exposing monitors for 2 to 6 months during specific periods of the year is also briefly discussed in this manual. However, the prompt alpha-track method has been validated only for use in the Mesa County, Colorado, area. 3 refs., 3 figs

  9. Manual tracing versus smartphone application (app) tracing: a comparative study.

    Science.gov (United States)

    Sayar, Gülşilay; Kilinc, Delal Dara

    2017-11-01

    This study aimed to compare the results of conventional manual cephalometric tracing with those acquired with smartphone application cephalometric tracing. The cephalometric radiographs of 55 patients (25 females and 30 males) were traced via the manual and app methods and were subsequently examined with Steiner's analysis. Five skeletal measurements, five dental measurements and two soft tissue measurements were managed based on 21 landmarks. The durations of the performances of the two methods were also compared. SNA (Sella, Nasion, A point angle) and SNB (Sella, Nasion, B point angle) values for the manual method were statistically lower (p < .001) than those for the app method. The ANB value for the manual method was statistically lower than that of app method. L1-NB (°) and upper lip protrusion values for the manual method were statistically higher than those for the app method. Go-GN/SN, U1-NA (°) and U1-NA (mm) values for manual method were statistically lower than those for the app method. No differences between the two methods were found in the L1-NB (mm), occlusal plane to SN, interincisal angle or lower lip protrusion values. Although statistically significant differences were found between the two methods, the cephalometric tracing proceeded faster with the app method than with the manual method.

  10. Annual Net Ecosystem Productivity of Wetlands: A Comparison of Automated and Manual Chamber Methods

    Science.gov (United States)

    Burrows, E. H.; Bubier, J. L.; Mosedale, A.; Crill, P. M.

    2001-05-01

    Net Ecosystem Exchange (NEE) of carbon dioxide (CO2) was measured in a minerotrophic poor fen in southeastern New Hampshire during the 2000 growing season using two types of chamber methods. Instantaneous CO2 flux was measured with transparent lexan and teflon static climate controlled chambers by calculating the change in headspace CO2 concentration in the chamber over time. Once per week the flux was sampled from ten manually operated chambers using a LI-COR 6200 portable photosynthesis system, which included a LI-6250 infrared gas analyzer, connected to the chambers. Ten automated chambers were installed in May of 2000, sampling CO2 flux every three hours over the diurnal cycle using a LI-COR 6262 infrared gas analyzer. The chambers and collars were placed throughout the fen in order to sample the range of plant communities. The manual sampling was done during the middle of the day, but the rate of photosynthesis changes depending on the amount of photosynthetically active radiation (PAR). In order to simulate varying light levels, shrouds blocking different amounts of light were placed over each manual chamber. An opaque shroud was used to measure respiration. NEE ranged from -13.0 to 12.5 μ mol CO2/m2/s in the manual chambers and -16.2 to 11.8 μ mol CO2/m2/s in the automated chambers for the mid-summer growing season. Manual respiration fluxes were measured under higher temperature regimes and the response of respiration to temperature will be factored in when comparing the two chamber techniques. Research during the summer of 2001 will also include diurnal measurements. Growing season net ecosystem productivity (NEP) will be estimated and compared for the two chamber systems. Several models will be used to estimate the flux when the manual chambers were not being sampled. The models will be based on biomass and dominant species in each chamber, and various environmental factors including water table, pH, relative humidity, PAR, air and peat temperature

  11. FURNACE; a toroidal geometry neutronic program system method description and users manual

    International Nuclear Information System (INIS)

    Verschuur, K.A.

    1984-12-01

    The FURNACE program system performs neutronic and photonic calculations in 3D toroidal geometry for application to fusion reactors. The geometry description is quite general, allowing any torus cross section and any neutron source density distribution for the plasma, as well as simple parametric representations of circular, elliptic and D-shaped tori and plasmas. The numerical method is based on an approximate transport model that produces results with sufficient accuracy for reactor-design purposes, at acceptable calculational costs. A short description is given of the numerical method, and a user manual for the programs of the system: FURNACE, ANISN-PT, LIBRA, TAPEMA and DRAWER is presented

  12. MARS CODE MANUAL VOLUME III - Programmer's Manual

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Hwang, Moon Kyu; Jeong, Jae Jun; Kim, Kyung Doo; Bae, Sung Won; Lee, Young Jin; Lee, Won Jae

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This programmer's manual provides a complete list of overall information of code structure and input/output function of MARS. In addition, brief descriptions for each subroutine and major variables used in MARS are also included in this report, so that this report would be very useful for the code maintenance. The overall structure of the manual is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  13. FBR metallic materials test manual (English version)

    International Nuclear Information System (INIS)

    Odaka, Susumu; Kato, Shoichi; Yoshida, Eiichi

    2003-06-01

    For the development of the fast breeder reactor, this manual describes the method of in-air and in-sodium material tests and the method of organization the data. This previous manual has revised in accordance with the revision of Japanese Industrial Standard (JIS) and the conversion to the international unit. The test methods of domestic committees such as the VAMAS (Versailles Project on Advanced Materials and Standards) workshop were also refereed. The material test technologies accumulated in this group until now were also incorporated. This English version was prepared in order to provide more engineers with the FBR metallic materials test manual. (author)

  14. NIOSH Manual of Analytical Methods (third edition). Fourth supplement

    Energy Technology Data Exchange (ETDEWEB)

    1990-08-15

    The NIOSH Manual of Analytical Methods, 3rd edition, was updated for the following chemicals: allyl-glycidyl-ether, 2-aminopyridine, aspartame, bromine, chlorine, n-butylamine, n-butyl-glycidyl-ether, carbon-dioxide, carbon-monoxide, chlorinated-camphene, chloroacetaldehyde, p-chlorophenol, crotonaldehyde, 1,1-dimethylhydrazine, dinitro-o-cresol, ethyl-acetate, ethyl-formate, ethylenimine, sodium-fluoride, hydrogen-fluoride, cryolite, sodium-hexafluoroaluminate, formic-acid, hexachlorobutadiene, hydrogen-cyanide, hydrogen-sulfide, isopropyl-acetate, isopropyl-ether, isopropyl-glycidyl-ether, lead, lead-oxide, maleic-anhydride, methyl-acetate, methyl-acrylate, methyl-tert-butyl ether, methyl-cellosolve-acetate, methylcyclohexanol, 4,4'-methylenedianiline, monomethylaniline, monomethylhydrazine, nitric-oxide, p-nitroaniline, phenyl-ether, phenyl-ether-biphenyl mixture, phenyl-glycidyl-ether, phenylhydrazine, phosphine, ronnel, sulfuryl-fluoride, talc, tributyl-phosphate, 1,1,2-trichloro-1,2,2-trifluoroethane, trimellitic-anhydride, triorthocresyl-phosphate, triphenyl-phosphate, and vinyl-acetate.

  15. Manual of analytical methods for the Environmental Health Laboratory

    International Nuclear Information System (INIS)

    Gray, C.E.

    1975-06-01

    The manual contains four sections: absorption spectrophotometry; general radiochemical procedures; instrumental analysis; and calibration of field instruments. Included in the individual analyses using absorption spectrophotometry is one for total iodine in oil. Radiochemical procedures are given for: actinides in urine and water; 137 Cs in soil and vegetation; 137 Cs in soil, urine, vegetation, and water; enriched uranium in urine; gross beta activity in soil, urine, vegetation, and water; plutonium in urine and soil; 210 Po in urine and water; 24 Na in air, blood, urine, and water; 90 Sr in soil, vegetation, and water; tritium in urine, water, and on swipes; and total uranium on fallout trays and in soil, urine, and water. Among the individual instrumental analyses is a spectrographic method for determining beryllium in air samples and swipes. (U.S.)

  16. US Department of Energy Radiological Control Manual

    International Nuclear Information System (INIS)

    1992-06-01

    This manual establishes practices for the conduct of radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. (VC)

  17. Radiotracers in medical applications, vols 1-2

    International Nuclear Information System (INIS)

    Rayudu, G.V.S.

    1983-01-01

    These volumes will serve as a basis for instruction and reference for professionals such as radiopharmaceutical chemists, radiopharmacologists, radiopharmacists, radiobiochemists, and others involved in the medical applications of radiotracers. Vol. I: Topics include radiohalogenated compounds, including radioiodine; Tc-labeled compounds; and in-house prepared radiopharmaceuticals. The charge particle range vs. energy in every element is tabulated for protons for cyclotrons users. Discussions are also provided on nonimaging radiotracer methods; 11 C, 13 N, 15 O, 67 Ga. 111 In, 75 Se, /SUP 123m/ Te compounds; radioactive noble gases; and miscellaneous radiotracers for imaging. Vol. II: Pertinent nuclear science data such as radiation dosimetry, radionuclide production modes, radionuclides for therapy, human experimentation regulations and consent forms, and radiotracer laboratory designs are presented

  18. Waste Management Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Buckingham, J.S. [ed.

    1967-08-31

    This Manual has been prepared to provide a documented compendium of the technical bases and general physical features of Isochem Incorporated`s Waste Management Program. The manual is intended to be used as a means of training and as a reference handbook for use by personnel responsible for executing the Waste Management Program. The material in this manual was assembled by members of Isochem`s Chemical Processing Division, Battelle Northwest Laboratory, and Hanford Engineering Services between September 1965 and March 1967. The manual is divided into the following parts: Introduction, contains a summary of the overall Waste Management Program. It is written to provide the reader with a synoptic view and as an aid in understanding the subsequent parts; Feed Material, contains detailed discussion of the type and sources of feed material used in the Waste Management Program, including a chapter on nuclear reactions and the formation of fission products; Waste Fractionization Plant Processing, contains detailed discussions of the processes used in the Waste Fractionization Plant with supporting data and documentation of the technology employed; Waste Fractionization Plant Product and Waste Effluent Handling, contains detailed discussions of the methods of handling the product and waste material generated by the Waste Fractionization Plant; Plant and Equipment, describes the layout of the Waste Management facilities, arrangement of equipment, and individual equipment pieces; Process Control, describes the instruments and analytical methods used for process control; and Safety describes process hazards and the methods used to safeguard against them.

  19. Tooth-size discrepancy: A comparison between manual and digital methods

    Directory of Open Access Journals (Sweden)

    Gabriele Dória Cabral Correia

    2014-08-01

    Full Text Available INTRODUCTION: Technological advances in Dentistry have emerged primarily in the area of diagnostic tools. One example is the 3D scanner, which can transform plaster models into three-dimensional digital models. OBJECTIVE: This study aimed to assess the reliability of tooth size-arch length discrepancy analysis measurements performed on three-dimensional digital models, and compare these measurements with those obtained from plaster models. MATERIAL AND METHODS: To this end, plaster models of lower dental arches and their corresponding three-dimensional digital models acquired with a 3Shape R700T scanner were used. All of them had lower permanent dentition. Four different tooth size-arch length discrepancy calculations were performed on each model, two of which by manual methods using calipers and brass wire, and two by digital methods using linear measurements and parabolas. RESULTS: Data were statistically assessed using Friedman test and no statistically significant differences were found between the two methods (P > 0.05, except for values found by the linear digital method which revealed a slight, non-significant statistical difference. CONCLUSIONS: Based on the results, it is reasonable to assert that any of these resources used by orthodontists to clinically assess tooth size-arch length discrepancy can be considered reliable.

  20. Manual vs. computer-assisted sperm analysis: can CASA replace manual assessment of human semen in clinical practice?

    Science.gov (United States)

    Talarczyk-Desole, Joanna; Berger, Anna; Taszarek-Hauke, Grażyna; Hauke, Jan; Pawelczyk, Leszek; Jedrzejczak, Piotr

    2017-01-01

    The aim of the study was to check the quality of computer-assisted sperm analysis (CASA) system in comparison to the reference manual method as well as standardization of the computer-assisted semen assessment. The study was conducted between January and June 2015 at the Andrology Laboratory of the Division of Infertility and Reproductive Endocrinology, Poznań University of Medical Sciences, Poland. The study group consisted of 230 men who gave sperm samples for the first time in our center as part of an infertility investigation. The samples underwent manual and computer-assisted assessment of concentration, motility and morphology. A total of 184 samples were examined twice: manually, according to the 2010 WHO recommendations, and with CASA, using the program set-tings provided by the manufacturer. Additionally, 46 samples underwent two manual analyses and two computer-assisted analyses. The p-value of p CASA and manually. In the group of patients where all analyses with each method were performed twice on the same sample we found no significant differences between both assessments of the same probe, neither in the samples analyzed manually nor with CASA, although standard deviation was higher in the CASA group. Our results suggest that computer-assisted sperm analysis requires further improvement for a wider application in clinical practice.

  1. A User's Manual for the NRN Shield Design Method

    Energy Technology Data Exchange (ETDEWEB)

    Hjaerne, Leif [ed.; Aalto, E; Fraeki, R; Leimdoerfer, M; Lindblom, K; Linde, S; Malen, K; Nyman, K

    1964-06-15

    This report describes a code system for bulk shield design written for a Ferranti Mercury computer and is intended as a manual for those using the programme. The idea of an 'almost direct' flux, as in the removal theory serves as a basis for further development of the theory. An important aspiration has been to minimize the manual work of administering the codes. The codes concerned are: NECO, computing necessary group constants from primary data, REFUSE and REBOX (infinite plane or cylindrical, and box geometry, respectively), computing removal flux, NEDI a one-dimensional (plane, spherical, cylindrical) diffusion multigroup code, and SALOME a Monte Carlo code computing the gamma flux. Output tapes are constructed for direct use as input tapes, when required, for a following code.

  2. A User's Manual for the NRN Shield Design Method

    International Nuclear Information System (INIS)

    Hjaerne, Leif; Aalto, E.; Fraeki, R.; Leimdoerfer, M.; Lindblom, K.; Linde, S.; Malen, K.; Nyman, K.

    1964-06-01

    This report describes a code system for bulk shield design written for a Ferranti Mercury computer and is intended as a manual for those using the programme. The idea of an 'almost direct' flux, as in the removal theory serves as a basis for further development of the theory. An important aspiration has been to minimize the manual work of administering the codes. The codes concerned are: NECO, computing necessary group constants from primary data, REFUSE and REBOX (infinite plane or cylindrical, and box geometry, respectively), computing removal flux, NEDI a one-dimensional (plane, spherical, cylindrical) diffusion multigroup code, and SALOME a Monte Carlo code computing the gamma flux. Output tapes are constructed for direct use as input tapes, when required, for a following code

  3. User Manuals for a Primary Care Electronic Medical Record System: A Mixed Methods Study of User- and Vendor-Generated Documents.

    Science.gov (United States)

    Shachak, Aviv; Dow, Rustam; Barnsley, Jan; Tu, Karen; Domb, Sharon; Jadad, Alejandro R; Lemieux-Charles, Louise

    2013-06-04

    Tutorials and user manuals are important forms of impersonal support for using software applications including electronic medical records (EMRs). Differences between user- and vendor documentation may indicate support needs, which are not sufficiently addressed by the official documentation, and reveal new elements that may inform the design of tutorials and user manuals. What are the differences between user-generated tutorials and manuals for an EMR and the official user manual from the software vendor? Effective design of tutorials and user manuals requires careful packaging of information, balance between declarative and procedural texts, an action and task-oriented approach, support for error recognition and recovery, and effective use of visual elements. No previous research compared these elements between formal and informal documents. We conducted an mixed methods study. Seven tutorials and two manuals for an EMR were collected from three family health teams and compared with the official user manual from the software vendor. Documents were qualitatively analyzed using a framework analysis approach in relation to the principles of technical documentation described above. Subsets of the data were quantitatively analyzed using cross-tabulation to compare the types of error information and visual cues in screen captures between user- and vendor-generated manuals. The user-developed tutorials and manuals differed from the vendor-developed manual in that they contained mostly procedural and not declarative information; were customized to the specific workflow, user roles, and patient characteristics; contained more error information related to work processes than to software usage; and used explicit visual cues on screen captures to help users identify window elements. These findings imply that to support EMR implementation, tutorials and manuals need to be customized and adapted to specific organizational contexts and workflows. The main limitation of the study

  4. User Manuals for a Primary Care Electronic Medical Record System: A Mixed Methods Study of User- and Vendor-Generated Documents

    Science.gov (United States)

    Dow, Rustam; Barnsley, Jan; Tu, Karen; Domb, Sharon; Jadad, Alejandro R.; Lemieux-Charles, Louise

    2015-01-01

    Research problem Tutorials and user manuals are important forms of impersonal support for using software applications including electronic medical records (EMRs). Differences between user- and vendor documentation may indicate support needs, which are not sufficiently addressed by the official documentation, and reveal new elements that may inform the design of tutorials and user manuals. Research question What are the differences between user-generated tutorials and manuals for an EMR and the official user manual from the software vendor? Literature review Effective design of tutorials and user manuals requires careful packaging of information, balance between declarative and procedural texts, an action and task-oriented approach, support for error recognition and recovery, and effective use of visual elements. No previous research compared these elements between formal and informal documents. Methodology We conducted an mixed methods study. Seven tutorials and two manuals for an EMR were collected from three family health teams and compared with the official user manual from the software vendor. Documents were qualitatively analyzed using a framework analysis approach in relation to the principles of technical documentation described above. Subsets of the data were quantitatively analyzed using cross-tabulation to compare the types of error information and visual cues in screen captures between user- and vendor-generated manuals. Results and discussion The user-developed tutorials and manuals differed from the vendor-developed manual in that they contained mostly procedural and not declarative information; were customized to the specific workflow, user roles, and patient characteristics; contained more error information related to work processes than to software usage; and used explicit visual cues on screen captures to help users identify window elements. These findings imply that to support EMR implementation, tutorials and manuals need to be customized and

  5. US Department of Energy radiological control manual

    International Nuclear Information System (INIS)

    1994-04-01

    This manual establishes practices for the conduct of Department of Energy radiological control activities. The Manual states DOE's positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. This Manual is not a substitute for Regulations; it is intended to be consistent with all relevant statutory and regulatory requirements and shall be revised whenever necessary to ensure such consistency. Some of the Manual provisions, however, challenge the user to go well beyond minimum requirements. Following the course of action delineated in the Manual will result in achieving and surpassing related statutory or regulatory requirements

  6. STECH VOL5 (1) FEBRUARY, 2016

    African Journals Online (AJOL)

    Copyright 1AARR 2012-2016: www.afrrevjo.net

    STECH VOL 5 (1) FEBRUARY, 2016. Vol. 5 (1), S/No11, February, 2016: 1-13 ..... Knowledge produce is an act of discovery which involves exploring, analyzing .... Architectural Research, Elsevier: Higher Education Press Limited Company.

  7. Method of Characteristic (MOC) Nozzle Flowfield Solver - User’s Guide and Input Manual Version 2.0

    Science.gov (United States)

    2018-01-01

    TECHNICAL REPORT RDMR-SS-17-13 METHOD OF CHARACTERISTIC (MOC) NOZZLE FLOWFIELD SOLVER—USER’S GUIDE AND INPUT MANUAL VERSION 2.0 Kevin D. Kennedy...1 II. PROGRAM READS AND WRITES ...2 B. Program Reads .................................................................................................. 4 C. Program Writes

  8. HASL procedures manual

    International Nuclear Information System (INIS)

    1980-08-01

    Addition and corrections to the following sections of the HASL Procedures Manual are provided: Table of Contents; Bibliography; Fallout Collection Methods; Wet/Dry Fallout Collection; Fluoride in Soil and Sediment; Strontium-90; Natural Series; Alpha Emitters; and Gamma Emitters

  9. Incidence rates of surgically treated rhegmatogenous retinal detachment among manual workers, non-manual workers and housewives in Tuscany, Italy

    OpenAIRE

    Curti, Stefania; Coggon, David; Baldasseroni, Alberto; Cooke, Robin M. T.; Fresina, Michela; Campos, Emilio C.; Semeraro, Francesco; Zanardi, Francesca; Farioli, Andrea; Violante, Francesco S.; Mattioli, Stefano

    2013-01-01

    Purpose Candidate risk factors for idiopathic rhegmatogenous retinal detachment (RRD) include heavy manual handling (requiring Valsalva’s maneuver). We assessed incidence rates of surgically treated idiopathic RRD among manual workers, non-manual workers and housewives resident in Tuscany, Italy. Methods We retrieved all hospital discharge records bearing a principal diagnosis corresponding to RRD coupled with retinal surgery for any resident of Tuscany during 1997–2009. After elimination of ...

  10. IOLMaster versus Manual Keratometry after Photorefractive Keratectomy

    Directory of Open Access Journals (Sweden)

    Hasan Razmju

    2011-01-01

    Full Text Available Purpose: To compare keratometric measurements using a Javal type manual keratometer with IOLMaster in eyes undergoing photorefractive keratectomy (PRK for myopia. Methods: In this comparative case series, we studied patients aged 21 to 27 years scheduled for myopic PRK. Keratometry was performed preoperatively and three months after the procedure using a Javal type manual keratometer and the IOLMaster. We compared postoperative measurements obtained by both instruments with the clinical history method (CHM. Results: Seventy eyes of 35 patients with mean age of 23.45±1.55 years were studied. Mean preoperative spherical equivalent was -4.53±1.3 D. Average preoperative IOLMaster and manual keratometric readings were 45.95±1.23 D and 46.32±1.18 D, respectively. Postoperatively, mean IOLMaster measurements was 38.03±0.68 D and that of manual keratometry was 43.15±1.1 D. Compared to CHM measurements, the 95% limits of agreement were ‑5.95 to -0.85 for the IOLMaster and -1.44 to 4.04 for manual keratometry. Conclusion: Keratometric measurements with the IOLMaster and a Javal type manual device are comparable after PRK; both are largely deviant from the CHM and can yield misleading results.

  11. Comparison of manual versus automated data collection method for an evidence-based nursing practice study.

    Science.gov (United States)

    Byrne, M D; Jordan, T R; Welle, T

    2013-01-01

    The objective of this study was to investigate and improve the use of automated data collection procedures for nursing research and quality assurance. A descriptive, correlational study analyzed 44 orthopedic surgical patients who were part of an evidence-based practice (EBP) project examining post-operative oxygen therapy at a Midwestern hospital. The automation work attempted to replicate a manually-collected data set from the EBP project. Automation was successful in replicating data collection for study data elements that were available in the clinical data repository. The automation procedures identified 32 "false negative" patients who met the inclusion criteria described in the EBP project but were not selected during the manual data collection. Automating data collection for certain data elements, such as oxygen saturation, proved challenging because of workflow and practice variations and the reliance on disparate sources for data abstraction. Automation also revealed instances of human error including computational and transcription errors as well as incomplete selection of eligible patients. Automated data collection for analysis of nursing-specific phenomenon is potentially superior to manual data collection methods. Creation of automated reports and analysis may require initial up-front investment with collaboration between clinicians, researchers and information technology specialists who can manage the ambiguities and challenges of research and quality assurance work in healthcare.

  12. Manual on quality assurance programme auditing

    International Nuclear Information System (INIS)

    1984-01-01

    The objective of this Manual is to provide guidance and illustrative examples of the methodology and techniques of internal and external audits that are consistent with the requirements and recommendations of the Code and the Safety Guide. The methodology and techniques are based on the practices of Member States having considerable experience in auditing QA programmes. This Manual is directed primarily towards QA programme auditors and managers and presents methods and techniques considered appropriate for the preparation and performance of audits and the evaluation of results. Its scope includes the techniques and methods used to carry out QA programme audits variously described as 'System', 'Product' and 'Process' audits. The techniques and methods described here may be used as one approach to the evaluation of suppliers' QA capabilities as defined in 50-SG-QA10. Although the Manual is primarily directed towards purchasers and suppliers, it is also relevant to regulatory organizations, such as government offices responsible for quality assurance, which carry out external audits independent of purchasers and suppliers. In such cases similar methods, procedures and techniques may be used

  13. Peace Corps Aquaculture Training Manual. Training Manual T0057.

    Science.gov (United States)

    Peace Corps, Washington, DC. Information Collection and Exchange Div.

    This Peace Corps training manual was developed from two existing manuals to provide a comprehensive training program in fish production for Peace Corps volunteers. The manual encompasses the essential elements of the University of Oklahoma program that has been training volunteers in aquaculture for 25 years. The 22 chapters of the manual are…

  14. Exploring intra- and inter-reader variability in uni-dimensional, bi-dimensional, and volumetric measurements of solid tumors on CT scans reconstructed at different slice intervals

    International Nuclear Information System (INIS)

    Zhao, Binsheng; Tan, Yongqiang; Bell, Daniel J.; Marley, Sarah E.; Guo, Pingzhen; Mann, Helen; Scott, Marietta L.J.; Schwartz, Lawrence H.; Ghiorghiu, Dana C.

    2013-01-01

    Objective: Understanding magnitudes of variability when measuring tumor size may be valuable in improving detection of tumor change and thus evaluating tumor response to therapy in clinical trials and care. Our study explored intra- and inter-reader variability of tumor uni-dimensional (1D), bi-dimensional (2D), and volumetric (VOL) measurements using manual and computer-aided methods (CAM) on CT scans reconstructed at different slice intervals. Materials and methods: Raw CT data from 30 patients enrolled in oncology clinical trials was reconstructed at 5, 2.5, and 1.25 mm slice intervals. 118 lesions in the lungs, liver, and lymph nodes were analyzed. For each lesion, two independent radiologists manually and, separately, using computer software, measured the maximum diameter (1D), maximum perpendicular diameter, and volume (CAM only). One of them blindly repeated the measurements. Intra- and inter-reader variability for the manual method and CAM were analyzed using linear mixed-effects models and Bland–Altman method. Results: For the three slice intervals, the maximum coefficients of variation for manual intra-/inter-reader variability were 6.9%/9.0% (1D) and 12.3%/18.0% (2D), and for CAM were 5.4%/9.3% (1D), 11.3%/18.8% (2D) and 9.3%/18.0% (VOL). Maximal 95% reference ranges for the percentage difference in intra-reader measurements for manual 1D and 2D, and CAM VOL were (−15.5%, 25.8%), (−27.1%, 51.6%), and (−22.3%, 33.6%), respectively. Conclusions: Variability in measuring the diameter and volume of solid tumors, manually and by CAM, is affected by CT slice interval. The 2.5 mm slice interval provides the least measurement variability. Among the three techniques, 2D has the greatest measurement variability compared to 1D and 3D

  15. Current automated 3D cell detection methods are not a suitable replacement for manual stereologic cell counting

    Directory of Open Access Journals (Sweden)

    Christoph eSchmitz

    2014-05-01

    Full Text Available Stereologic cell counting has had a major impact on the field of neuroscience. A major bottleneck in stereologic cell counting is that the user must manually decide whether or not each cell is counted according to three-dimensional (3D stereologic counting rules by visual inspection within hundreds of microscopic fields-of-view per investigated brain or brain region. Reliance on visual inspection forces stereologic cell counting to be very labor-intensive and time-consuming, and is the main reason why biased, non-stereologic two-dimensional (2D cell counting approaches have remained in widespread use. We present an evaluation of the performance of modern automated cell detection and segmentation algorithms as a potential alternative to the manual approach in stereologic cell counting. The image data used in this study were 3D microscopic images of thick brain tissue sections prepared with a variety of commonly used nuclear and cytoplasmic stains. The evaluation compared the numbers and locations of cells identified unambiguously and counted exhaustively by an expert observer with those found by three automated 3D cell detection algorithms: nuclei segmentation from the FARSIGHT toolkit, nuclei segmentation by 3D multiple level set methods, and the 3D object counter plug-in for ImageJ. Of these methods, FARSIGHT performed best, with true-positive detection rates between 38–99% and false-positive rates from 3.6–82%. The results demonstrate that the current automated methods suffer from lower detection rates and higher false-positive rates than are acceptable for obtaining valid estimates of cell numbers. Thus, at present, stereologic cell counting with manual decision for object inclusion according to unbiased stereologic counting rules remains the only adequate method for unbiased cell quantification in histologic tissue sections.

  16. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis

    Directory of Open Access Journals (Sweden)

    Fatma Demet Ä°nce

    2016-08-01

    Full Text Available Objectives: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. Design and methods: 209 urine samples were analyzed by the Iris iQ200 ELITE (Ä°ris Diagnostics, USA, Dirui FUS-200 (DIRUI Industrial Co., China automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient and the rates within the same grading were evaluated. Results: For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. Conclusion: The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization. Keywords: Urinalysis, Autoanalysis, Microscopy

  17. Manual on decontamination of surfaces

    International Nuclear Information System (INIS)

    1979-01-01

    The manual is intended for those who are responsible for the organization and implementation of decontamination programmes for facilities where radioactive materials are handled mainly on a laboratory scale. It contains information and guidelines on practical methods for decontaminating working spaces, equipment, laboratory benches and protective clothing. Useful information is also provided on the removal of loose skin contamination from personnel by mild, non-medical processes. Methods of removing skin contamination needing medical supervision, or of internal decontamination, which is entirely a medical process, are not covered in this manual. Large-scale decontamination of big nuclear facilities is also considered as outside its scope

  18. Semi-automating the manual literature search for systematic reviews increases efficiency.

    Science.gov (United States)

    Chapman, Andrea L; Morgan, Laura C; Gartlehner, Gerald

    2010-03-01

    To minimise retrieval bias, manual literature searches are a key part of the search process of any systematic review. Considering the need to have accurate information, valid results of the manual literature search are essential to ensure scientific standards; likewise efficient approaches that minimise the amount of personnel time required to conduct a manual literature search are of great interest. The objective of this project was to determine the validity and efficiency of a new manual search method that utilises the scopus database. We used the traditional manual search approach as the gold standard to determine the validity and efficiency of the proposed scopus method. Outcome measures included completeness of article detection and personnel time involved. Using both methods independently, we compared the results based on accuracy of the results, validity and time spent conducting the search, efficiency. Regarding accuracy, the scopus method identified the same studies as the traditional approach indicating its validity. In terms of efficiency, using scopus led to a time saving of 62.5% compared with the traditional approach (3 h versus 8 h). The scopus method can significantly improve the efficiency of manual searches and thus of systematic reviews.

  19. Camellia v1.0 Manual: Part I

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, Nathan V. [Argonne National Lab. (ANL), Argonne, IL (United States). Argonne Leadership Computing Facility

    2016-09-28

    Camellia began as an effort to simplify implementation of efficient solvers for the discontinuous Petrov-Galerkin (DPG) finite element methodology of Demkowicz and Gopalakrishnan. Since then, the feature set has expanded, to allow implementation of traditional continuous Galerkin methods, as well as discontinuous Galerkin (DG) methods, hybridizable DG (HDG) methods, first-order-system least squares (FOSLS), and the primal DPG method. This manual serves as an introduction to using Camellia. We begin, in Section 1.1, by describing some of the core features of Camellia. In Section 1.2 we provide an outline of the manual as a whole.

  20. A novel method for the quantification of key components of manual dexterity after stroke

    OpenAIRE

    T?r?metz, Maxime; Colle, Florence; Hamdoun, Sonia; Maier, Marc A.; Lindberg, P?vel G.

    2015-01-01

    Background A high degree of manual dexterity is a central feature of the human upper limb. A rich interplay of sensory and motor components in the hand and fingers allows for independent control of fingers in terms of timing, kinematics and force. Stroke often leads to impaired hand function and decreased manual dexterity, limiting activities of daily living and impacting quality of life. Clinically, there is a lack of quantitative multi-dimensional measures of manual dexterity. We therefore ...

  1. Microbial ecology laboratory procedures manual NASA/MSFC

    Science.gov (United States)

    Huff, Timothy L.

    1990-01-01

    An essential part of the efficient operation of any microbiology laboratory involved in sample analysis is a standard procedures manual. The purpose of this manual is to provide concise and well defined instructions on routine technical procedures involving sample analysis and methods for monitoring and maintaining quality control within the laboratory. Of equal importance is the safe operation of the laboratory. This manual outlines detailed procedures to be followed in the microbial ecology laboratory to assure safety, analytical control, and validity of results.

  2. Reproducibility of Manual Platelet Estimation Following Automated Low Platelet Counts

    Directory of Open Access Journals (Sweden)

    Zainab S Al-Hosni

    2016-11-01

    Full Text Available Objectives: Manual platelet estimation is one of the methods used when automated platelet estimates are very low. However, the reproducibility of manual platelet estimation has not been adequately studied. We sought to assess the reproducibility of manual platelet estimation following automated low platelet counts and to evaluate the impact of the level of experience of the person counting on the reproducibility of manual platelet estimates. Methods: In this cross-sectional study, peripheral blood films of patients with platelet counts less than 100 × 109/L were retrieved and given to four raters to perform manual platelet estimation independently using a predefined method (average of platelet counts in 10 fields using 100× objective multiplied by 20. Data were analyzed using intraclass correlation coefficient (ICC as a method of reproducibility assessment. Results: The ICC across the four raters was 0.840, indicating excellent agreement. The median difference of the two most experienced raters was 0 (range: -64 to 78. The level of platelet estimate by the least-experienced rater predicted the disagreement (p = 0.037. When assessing the difference between pairs of raters, there was no significant difference in the ICC (p = 0.420. Conclusions: The agreement between different raters using manual platelet estimation was excellent. Further confirmation is necessary, with a prospective study using a gold standard method of platelet counts.

  3. Evaluation of the PREVI® Isola automated seeder system compared to reference manual inoculation for antibiotic susceptibility testing by the disk diffusion method.

    Science.gov (United States)

    Le Page, S; van Belkum, A; Fulchiron, C; Huguet, R; Raoult, D; Rolain, J-M

    2015-09-01

    The disk diffusion (DD) method remains the most popular manual technique for antibiotic susceptibility testing (AST) in clinical microbiology laboratories. This is because of its simplicity, reproducibility, and limited cost compared to (automated) microdilution systems, which are usually less sensitive at detecting certain important mechanisms of resistance. Here, we evaluate the PREVI® Isola automated seeder system using a new protocol for spreading bacterial suspensions (eight deposits of calibrated inocula of bacteria, followed by two rounds of rotation) in comparison with manual DD reference testing on a large series of clinical and reference strains. The average time required for seeding one agar plate for DD with this new protocol was 51 s per plate, i.e., 70 agar plates/h. Reproducibility and repeatability was assessed on three reference and three randomly chosen clinical strains, as usually requested by the European Committee on Antimicrobial Susceptibility Testing (EUCAST), and was excellent compared to the manual method. The standard deviations of zones of growth inhibition showed no statistical discrimination. The correlation between the two methods, assessed using 294 clinical isolates and a panel of six antibiotics (n = 3,528 zones of growth inhibition measured), was excellent, with a correlation coefficient of 0.977. The new PREVI® Isola protocol adapted for DD had a sensitivity of 99 % and a specificity of 100 % compared to the manual technique for interpreting DD as recommended by the EUCAST.

  4. Manual Intracardiac Electrogram Method Is Accurate Alternative to Echocardiography for Atrioventricular and Interventricular Optimization in Cardiac Resynchronization Therapy.

    Science.gov (United States)

    Pezo Nikolić, Borka; Lovrić, Daniel; Ljubas Maček, Jana; Rešković Lukšić, Vlatka; Matasić, Richard; Šeparović Hanževački, Jadranka

    2017-12-01

    Some manufacturers do not provide automated intracardiac electrogram method (IEGM) systems for atrioventricular (AV) and interventricular (VV) delay optimization in cardiac resynchronization therapy (CRT). We aimed to evaluate the accuracy of manual IEGM method in 48 patients previously implanted with Medtronic Syncra CRT. All patients underwent standard device interrogation followed by CRT optimization by IEGM method and by echocardiography one month after implantation. The patient mean age was 60.7±11.8 years and there were 33 (68.8%) males. After CRT implantation, the left ventricular ejection fraction increased from 28.0±7.9% to 39.1±11.0% (p<0.001). Optimal aortic flow Velocity Time Integral (aVTI) was obtained when VV was set to 20-50 ms left ventricular pre-activation. There was a strong correlation between VV values determined by echocardiography and IEGM (R=0.823, p<0.001). We found no significant difference in AV, VV and aVTI values between echocardiography and IEGM method. However, IEGM was significantly less time-consuming than echocardiography [20 (10-28) vs. 40 (35-60) minutes, p<0.001]. Manual IEGM method may be good alternative to echocardiography and automated IEGM method. It also emphasizes the need for implementation of automated IEGM systems in as many CRT devices as possible.

  5. Nuclear medicine. 1 part. Manual

    International Nuclear Information System (INIS)

    Shlygina, O.E.; Borisenko, A.R.

    2006-01-01

    Current manual is urged to give wide-scale readers a submission on a key principles and methods of nuclear medicine, and it opportunities and restrictions in diagnostics and treatment of different diseases. Nuclear medicine is differing first of all by combination of diverse knowledge fields: special knowledge of a doctor, knowledge of physical processes bases, related with radiation, grounds of radiopharmaceutics, dosimetry. In the base of the book the 5th edition of 'Nuclear medicine' manual in 2 parts of German authors - Schicha, G.; Schober, O. is applied. In the book publishing the stuff of the Institute of Nuclear Physics of the National Nuclear Center of Republic of Kazakhstan has been worked. Modifications undergo practically all chapters: especially the second one, forth and sixth was enlarged. The 1 part of the book was published due to support of IAEA within the Technical cooperation project 'Implementation of Nuclear Medicine and Biophysics Center' (KAZ/6/007). The manual second part - devoted to applications of nuclear medicine methods for diagnostics and treatment - will be published in 2007

  6. A comparison between the conventional manual ROI method and an automatic algorithm for semiquantitative analysis of SPECT studies

    International Nuclear Information System (INIS)

    Pagan, L; Novi, B; Guidarelli, G; Tranfaglia, C; Galli, S; Lucchi, G; Fagioli, G

    2011-01-01

    In this study, the performance of a free software for automatic segmentation of striatal SPECT brain studies (BasGanV2 - www.aimn.it) and a standard manual Region Of Interest (ROI) method were compared. The anthropomorphic Alderson RSD phantom, filled with solutions at different concentration of 123 I-FP-CIT with Caudate-Putamen to Background ratios between 1 and 8.7 and Caudate to Putamen ratios between 1 and 2, was imaged on a Philips-Irix triple head gamma camera. Images were reconstructed using filtered back-projection and processed with both BasGanV2, that provides normalized striatal uptake values on volumetric anatomical ROIs, and a manual method, based on average counts per voxel in ROIs drawn in a three-slice section. Caudate-Putamen/Background and Caudate/Putamen ratios obtained with the two methods were compared with true experimental ratios. Good correlation was found for each method; BasGanV2, however, has higher R index (BasGan R mean = 0.95, p mean = 0.89, p 123 I-FP-CIT SPECT data with, moreover, the advantage of the availability of a control subject's database.

  7. Computer-based automated left atrium segmentation and volumetry from ECG-gated coronary CT angiography data. Comparison with manual slice segmentation and ultrasound planimetric methods

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, R.W.; Kraus, B.; Kerl, J.M.; Lehnert, T.; Vogl, T.J. [Universitaetsklinikum Frankfurt (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Bernhardt, D.; Vega-Higuera, F. [Siemens AG, Healthcare Sector, Forchheim (Germany). Computed Tomography; Ackermann, H. [Universitaetsklinikum Frankfurt (Germany). Inst. fuer Biostatistik und Mathematische Modellierung

    2010-12-15

    Purpose: Enlargement of the left atrium is a risk factor for cardiovascular or cerebrovascular events. We evaluated the performance of prototype software for fully automated segmentation and volumetry of the left atrium. Materials and Methods: In 34 retrospectively ECG-gated coronary CT angiography scans, the end-systolic (LAVsys) and end-diastolic (LAVdia) volume of the left atrium was calculated fully automatically by prototype software. Manual slice segmentation by two independent experienced radiologists served as the reference standard. Furthermore, two independent observers calculated the LAV utilizing two ultrasound planimetric methods ('area length' and 'prolate ellipse') on CTA images. Measurement periods were compared for all methods. Results: The left atrial volumes calculated with the prototype software were in excellent agreement with the results from manual slice segmentation (r = 0.97 - 0.99; p < 0.001; Bland-Altman) with excellent interobserver agreement between both radiologists (r = 0.99; p < 0.001). Ultrasound planimetric methods clearly showed a higher variation (r = 0.72 - 0.86) with moderate interobserver agreement (r = 0.51 - 0.79). The measurement period was significantly lower with the software (267 {+-} 28 sec; p < 0.001) than with ultrasound methods (431 {+-} 68 sec) or manual slice segmentation (567 {+-} 91 sec). Conclusion: The prototype software showed excellent agreement with manual slice segmentation with the least time consumption. This will facilitate the routine assessment of the LA volume from coronary CTA data and therefore risk stratification. (orig.)

  8. Methane measurements manual; Handbok metanmaetningar

    Energy Technology Data Exchange (ETDEWEB)

    Holmgren, Magnus Andreas (SP Technical research institute of Sweden, Boraas (Sweden))

    2011-02-15

    Emissions to air in different parts of the system may arise in biogas plants, where there is biological treatment of organic matter by anaerobic degradation, and during upgrading of biogas to vehicle fuel. There are mainly four reasons why these emissions must be minimized. These are safety, greenhouse gas emissions, economy and smell. This manual gathers experience of several years of work with measurement of methane emissions from biogas and upgrading facilities. This work has been done mainly in the context of Swedish Waste Management's system of voluntary commitment. The purpose of this manual is to standardize methods and procedures when methane measurements are carried out so that the results are comparable between different providers. The main target group of the manual is measurement consultants performing such measurements. Calculation template in Excel is part of the manual, which further contributes to the measurements evaluated in a standardized way. The manual contains several examples which have been calculated in the accompanying Excel template. The handbook also contains a chapter mainly intended for facility staff, in which implementation of accurate leak detection is described, and where there are hints of a system of so-called intermediate inspections to detect leaks in time

  9. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis.

    Science.gov (United States)

    İnce, Fatma Demet; Ellidağ, Hamit Yaşar; Koseoğlu, Mehmet; Şimşek, Neşe; Yalçın, Hülya; Zengin, Mustafa Osman

    2016-08-01

    Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization.

  10. INTRA/Mod3.2. Manual and Code Description. Volume I - Physical Modelling

    International Nuclear Information System (INIS)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the Physical modelling of INTRA and the ruling numerical methods and volume II, the User's Manual is an input description. This document, the Physical modelling of INTRA, contains code characteristics, integration methods and applications

  11. INTRA/Mod3.2. Manual and Code Description. Volume I - Physical Modelling

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Jenny; Edlund, O; Hermann, J; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the Physical modelling of INTRA and the ruling numerical methods and volume II, the User`s Manual is an input description. This document, the Physical modelling of INTRA, contains code characteristics, integration methods and applications

  12. US Department of Energy radiological control manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-01

    This manual establishes practices for the conduct of Department of Energy radiological control activities. The Manual states DOE`s positions and views on the best courses of action currently available in the area of radiological controls. Accordingly, the provisions in the Manual should be viewed by contractors as an acceptable technique, method or solution for fulfilling their duties and responsibilities. This Manual shall be used by DOE in evaluating the performance of its contractors. This Manual is not a substitute for Regulations; it is intended to be consistent with all relevant statutory and regulatory requirements and shall be revised whenever necessary to ensure such consistency. Some of the Manual provisions, however, challenge the user to go well beyond minimum requirements. Following the course of action delineated in the Manual will result in achieving and surpassing related statutory or regulatory requirements.

  13. Crisis Communication (Handbooks of Communication Science Vol. 23)

    DEFF Research Database (Denmark)

    Johansen, Winni

    Vol. 23 - The Handbook of Communication Science General editors: Peter J. Schultz and Paul Cobley......Vol. 23 - The Handbook of Communication Science General editors: Peter J. Schultz and Paul Cobley...

  14. VLE measurements using a static cell vapor phase manual sampling method accompanied with an empirical data consistency test

    International Nuclear Information System (INIS)

    Freitag, Joerg; Kosuge, Hitoshi; Schmelzer, Juergen P.; Kato, Satoru

    2015-01-01

    Highlights: • We use a new, simple static cell vapor phase manual sampling method (SCVMS) for VLE (x, y, T) measurement. • The method is applied to non-azeotropic, asymmetric and two-liquid phase forming azeotropic binaries. • The method is approved by a data consistency test, i.e., a plot of the polarity exclusion factor vs. pressure. • The consistency test reveals that with the new SCVMS method accurate VLE near ambient temperature can be measured. • Moreover, the consistency test approves that the effect of air in the SCVMS system is negligible. - Abstract: A new static cell vapor phase manual sampling (SCVMS) method is used for the simple measurement of constant temperature x, y (vapor + liquid) equilibria (VLE). The method was applied to the VLE measurements of the (methanol + water) binary at T/K = (283.2, 298.2, 308.2 and 322.9), asymmetric (acetone + 1-butanol) binary at T/K = (283.2, 295.2, 308.2 and 324.2) and two-liquid phase forming azeotropic (water + 1-butanol) binary at T/K = (283.2 and 298.2). The accuracy of the experimental data was approved by a data consistency test, that is, an empirical plot of the polarity exclusion factor, β, vs. the system pressure, P. The SCVMS data are accurate, because the VLE data converge to the same lnβ vs. lnP straight line determined from conventional distillation-still method and a headspace gas chromatography method

  15. Procedure manual for the estimation of average indoor radon-daughter concentrations using the radon grab-sampling method

    International Nuclear Information System (INIS)

    George, J.L.

    1986-04-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center to provide standardization, calibration, comparability, verification of data, quality assurance, and cost-effectiveness for the measurement requirements of DOE remedial action programs. One of the remedial-action measurement needs is the estimation of average indoor radon-daughter concentration. One method for accomplishing such estimations in support of DOE remedial action programs is the radon grab-sampling method. This manual describes procedures for radon grab sampling, with the application specifically directed to the estimation of average indoor radon-daughter concentration (RDC) in highly ventilated structures. This particular application of the measurement method is for cases where RDC estimates derived from long-term integrated measurements under occupied conditions are below the standard and where the structure being evaluated is considered to be highly ventilated. The radon grab-sampling method requires that sampling be conducted under standard maximized conditions. Briefly, the procedure for radon grab sampling involves the following steps: selection of sampling and counting equipment; sample acquisition and processing, including data reduction; calibration of equipment, including provisions to correct for pressure effects when sampling at various elevations; and incorporation of quality-control and assurance measures. This manual describes each of the above steps in detail and presents an example of a step-by-step radon grab-sampling procedure using a scintillation cell

  16. Research on condensed matter and atomic physics using major experimental facilities and devices: Physics, chemistry, biology. Reports on results. Vol. 3. 4. Chemistry. 5. Biology. 6. Development of methods and instruments

    International Nuclear Information System (INIS)

    1993-01-01

    This report in three volumes substantiates the contents of the programme survey published in September 1989. The progress reports cover the following research areas: Vol. I, (1). Atomic and molecular physics - free atoms, molecules, macromolecules, clusters, matrix-isolated atoms and molecules. (2) Physics and chemistry of surfaces and interfaces - epitaxy, surface structure, adsorption, electrical, magnetic, and optical properties, thin films, synthetic layer structure. Vol. II, (3). Solid-state physics, and materials science -structural research, lattice dynamics, magnetic structure and dynamics, electronic states; load; spin and pulse density fluctuations; diffusion and internal motion, defects, unordered systems and liquids. Vol. III, (4). Chemistry - bonding and structure, kinetics and reaction mechanisms, polymer research, analysis and synthesis. (5). Biology, - structure and dynamics of biological macromolecules, membrane and cell biology. (6) Development of methods and instruments - neutron sources, synchrotron sources, special accelerators, research with interlinked systems and devices. (orig.) [de

  17. Development on the High-throughput Vol-oxidizer for Decladding and Voloxidation of Spent Fuel Rod-cuts

    International Nuclear Information System (INIS)

    Kim, Young Hwang; Jung, Jae Hoo; Kim, Ki Ho; Park, Byung Buk; Lee, Hyo Jik; Kim, Sung Hyun; Park, Hee Sung; Lee, Jong Kwang; Kim, Ho Dong

    2009-12-01

    A high-throughput vol-oxidizer which can handle a several ten kg HM/batch is being developed to supply U 3 O 8 powders to an electrolytic reduction reactor in pyro-processing. At the first year step(2007), for enhancement of oxidation and recovery rate, we analyzed the mechanical and chemical methods, and devised the main mechanism with ball drop methods and rotary kiln type. Also, the main devices for oxidation and recovery of rod-cuts were designed by using the Solid Works and COSMOS program tools, and manufactured after thermal/mechanical analysis. In order to verify the main devices, simulation fuels(W 90%+SiO 2 10%) were manufactured and the main devices were tested for the oxidation and recovery rate of its. Here the expansion ratio of simulation fuel is similar to U 3 O 8 (2.7). At the second year step(2008), with the constant ration of rod-cuts volume and expansion ratio of U 3 O 8 (2.7), we produced a theoretical equation that can estimate the volume of rod-cuts according to a variation of their weight and lengths. We considered various materials such as ceramics and Ni-Cr, finally, the APM material which can constantly maintain against high temperature(1,200 .deg. C) and vacuum(1 torr) was selected and a vol-oxidizer was designed. At the third year step(2009), in order to manufacture a high-throughput vol-oxidizer, we have analyzed the vol-oxidizer for remote operability and maintainability, also the remote assembling and disassembling possibilities of the selected modules have been analyzed in terms of visibility, interference, approach, weight, and so on. We have presented final modular design and manufactured a high-throughput vol-oxidizer. Also, we have conducted the blank, heating(over 500 .deg. C) and hull separation test(capacity : 50 kg HM/batch, hull length 50mm) on the high-throughput vol-oxidizer. Also, these design technologies for the high-throughput vol-oxidizer will be utilized in the development of a more efficient vol-oxidizer with higher

  18. Comparison of semi-automated and manual measurements of carotid intima-media thickening.

    LENUS (Irish Health Repository)

    Mac Ananey, Oscar

    2014-01-01

    Carotid intima-media thickening (CIMT) is a marker of both arteriosclerotic and atherosclerotic risks. Technological advances have semiautomated CIMT image acquisition and quantification. Studies comparing manual and automated methods have yielded conflicting results possibly due to plaque inclusion in measurements. Low atherosclerotic risk subjects (n = 126) were recruited to minimise the effect of focal atherosclerotic lesions on CIMT variability. CIMT was assessed by high-resolution B-mode ultrasound (Philips HDX7E, Phillips, UK) images of the common carotid artery using both manual and semiautomated methods (QLAB, Phillips, UK). Intraclass correlation coefficient (ICC) and the mean differences of paired measurements (Bland-Altman method) were used to compare both methodologies. The ICC of manual (0.547 ± 0.095 mm) and automated (0.524 ± 0.068 mm) methods was R = 0.74 and an absolute mean bias ± SD of 0.023 ± 0.052 mm was observed. Interobserver and intraobserver ICC were greater for automated (R = 0.94 and 0.99) compared to manual (R = 0.72 and 0.88) methods. Although not considered to be clinically significant, manual measurements yielded higher values compared to automated measurements. Automated measurements were more reproducible and showed lower interobserver variation compared to manual measurements. These results offer important considerations for large epidemiological studies.

  19. comparative analysis of mechanical and manual modes of traffic

    African Journals Online (AJOL)

    user

    with a difference of (0.999x10^6 ) between the mechanical and manual, this value shows a downward effect using manual data .... Various methods can be adopted for verification such as listed ..... Maintenance cost is high using mechanical.

  20. Comparison of manual and automated pretreatment methods for AMS radiocarbon dating of plant fossils

    Science.gov (United States)

    Bradley, L.A.; Stafford, Thomas W.

    1994-01-01

    A new automated pretreatment system for the preparation of materials submitted for accelerator mass spectrometry (AMS) analysis is less time-consuming and results in a higher sample yield. The new procedure was tested using two groups of plant fossils: one group was pretreated using the traditional method, and the second, using the automated pretreatment apparatus. The time it took to complete the procedure and the amount of sample material remaining were compared. The automated pretreatment apparatus proved to be more than three times faster and, in most cases, produced a higher yield. A darker discoloration of the KOH solutions was observed indicating that the automated system is more thorough in removing humates from the specimen compared to the manual method. -Authors

  1. Development of a SCAT data management manual

    International Nuclear Information System (INIS)

    Lamarche, A.; Owens, E.H.

    2005-01-01

    The Shoreline Cleanup Assessment Technique (SCAT) is a commonly used method in North America to document oiling conditions in the aftermath of an oil spill. The data generated by SCAT can support all aspects of the process needed to develop and apply shoreline treatment methods such as planning treatment strategies, selecting treatment methods, providing detailed instructions to response personnel and evaluating the response effort. In order to be effective, SCAT data must be validated, entered within computerized systems, and transformed into support documents such as maps, tables and reports. This paper describes the development of a guidance manual for SCAT data coordinators and spill response managers that use the results of SCAT data. Guidance is presented for emergency procedures that enable the generation of minimal, but adequate, SCAT data management services. The creation of the manual involved the development of formal descriptions of the role, responsibilities and abilities of the SCAT data management team. The manual provides solution to several data processing issues, including those related to the presence of multiple parallel bands of oil within a segment of shoreline. Summary tables were created to report the length of oiled shoreline by oiling category and to present surface oiling characteristics in overview maps. The manual also includes details on how SCAT data is used for response planning, decision making and to support operations. 12 refs., 7 tabs., 8 figs

  2. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: Comparison of a manual and automated 3D volume segmentation method

    International Nuclear Information System (INIS)

    Wolf, Florian; Ourednicek, Petr; Loewe, Christian; Richter, Bernhard; Goessinger, Heinz David; Gwechenberger, Marianne; Plank, Christina; Schernthaner, Ruediger Egbert; Toepker, Michael; Lammer, Johannes; Feuchtner, Gudrun M.

    2010-01-01

    Introduction: The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT). Methods and materials: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated. Results: Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p > 0.05) and high Pearsons correlation coefficients (r = 0.94, r = 0.94, r = 0.82 and r = 0.85, p < 0.0001), respectively. The automated method was significantly faster (p < 0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p < 0.0001). Conclusions: Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

  3. Evaluation of left atrial function by multidetector computed tomography before left atrial radiofrequency-catheter ablation: Comparison of a manual and automated 3D volume segmentation method

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Florian, E-mail: florian.wolf@meduniwien.ac.a [Department of Radiology, Medical University of Vienna, Vienna (Austria); Ourednicek, Petr [Philips Medical Systems, Prague (Czech Republic); Loewe, Christian [Department of Radiology, Medical University of Vienna, Vienna (Austria); Richter, Bernhard; Goessinger, Heinz David; Gwechenberger, Marianne [Department of Cardiology, Medical University of Vienna, Vienna (Austria); Plank, Christina; Schernthaner, Ruediger Egbert; Toepker, Michael; Lammer, Johannes [Department of Radiology, Medical University of Vienna, Vienna (Austria); Feuchtner, Gudrun M. [Department of Radiology, Innsbruck Medical University, Innsbruck (Austria); Institute of Diagnostic Radiology, University Hospital Zurich (Switzerland)

    2010-08-15

    Introduction: The purpose of this study was to compare a manual and automated 3D volume segmentation tool for evaluation of left atrial (LA) function by 64-slice multidetector-CT (MDCT). Methods and materials: In 33 patients with paroxysmal atrial fibrillation a MDCT scan was performed before radiofrequency-catheter ablation. Atrial function (minimal volume (LAmin), maximal volume (LAmax), stroke volume (SV), ejection fraction (EF)) was evaluated by two readers using a manual and an automatic tool and measurement time was evaluated. Results: Automated LA volume segmentation failed in one patient due to low LA enhancement (103HU). Mean LAmax, LAmin, SV and EF were 127.7 ml, 93 ml, 34.7 ml, 27.1% by the automated, and 122.7 ml, 89.9 ml, 32.8 ml, 26.3% by the manual method with no significant difference (p > 0.05) and high Pearsons correlation coefficients (r = 0.94, r = 0.94, r = 0.82 and r = 0.85, p < 0.0001), respectively. The automated method was significantly faster (p < 0.001). Interobserver variability was low for both methods with Pearson's correlation coefficients between 0.98 and 0.99 (p < 0.0001). Conclusions: Evaluation of LA volume and function with 64-slice MDCT is feasible with a very low interobserver variability. The automatic method is as accurate as the manual method but significantly less time consuming permitting a routine use in clinical practice before RF-catheter ablation.

  4. Bulletin of the Chemical Society of Ethiopia - Vol 27, No 3 (2013)

    African Journals Online (AJOL)

    Bulletin of the Chemical Society of Ethiopia - Vol 27, No 3 (2013) ... of the psychoactive phenylpropylamino alkaloids of khat (Catha edulis Forsk) chewing ... Synthesis and characterization of CdTe quantum dots by one-step method · EMAIL ...

  5. Manual Therapy

    OpenAIRE

    Hakgüder, Aral; Kokino, Siranuş

    2002-01-01

    Manual therapy has been used in the treatment of pain and dysfunction of spinal and peripheral joints for more than a hundred years. Manual medicine includes manipulation, mobilization, and postisometric relaxation techniques. The aim of manual therapy is to enhance restricted movement caused by blockage of joints keeping postural balance, restore function and maintain optimal body mechanics. Anatomic, biomechanical, and neurophysiological evaluations of the leucomotor system is essential for...

  6. Design/CPN. A Reference Manual

    DEFF Research Database (Denmark)

    Jensen et. al, Kurt

    /CPN WWW pages. To speed up the access to the Design/CPN manuals we recommend to keep a local copy - which may be shared by all users in your organisation. In this way you do not need to go via our WWW server each time you need to look in a manual. For some of the largest manuals, we also supply files......Note: The manuals are available as PDF files . There are two sets of manuals - one for the Unix platform and another for the Mac platform. Each set of manual consists of: Tutorial (for the Design/CPN editor and simulator) Reference Manual (for the Design/CPN editor and simulator) Programmer......'s Manual (with Design/OA functions and Charts) Occurrence Graph Manual (integrated tutorial and reference manual) OE/OS Graph Manual (integrated tutorial and reference manual) Other Manuals (e.g. a short overview of CPN ML).   The Tutorial, Reference Manual and Programmer's Manual are made for Design...

  7. Caltrans : construction manual

    Science.gov (United States)

    2009-08-01

    Caltrans intends this manual as a resource for all personnel engaged in contract administration. The manual establishes policies and procedures for the construction phase of Caltrans projects. However, this manual is not a contract document. It impos...

  8. Develpment of quality assurance manual for fabrication of DUPIC fuel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Gun; Lee, J. W.; Kim, S. S. and others

    2001-09-01

    The Quality Assurance Manual for the fabrication of DUPIC fuel with high quality was developed. The Quality Assurance Policy established by this manual is to assure that the DUPIC fuel element supplied to customer conform to the specified requirements of customer, applicable codes and standards. The management of KAERI is committed to implementation and maintenance of the program described by this manual. This manual describes the quality assurance program for DUPIC fuel fabrication to comply with CAN3-Z299.2-85 to the extent as needed and appropriate. This manual describes the methods which DUPIC Fuel Development Team(DFDT) personnel must follow to achieve and assure high quality of our product. This manual also describes the quality management system applicable to the activities performed at DFDT.

  9. Develpment of quality assurance manual for fabrication of DUPIC fuel

    International Nuclear Information System (INIS)

    Lee, Young Gun; Lee, J. W.; Kim, S. S. and others

    2001-09-01

    The Quality Assurance Manual for the fabrication of DUPIC fuel with high quality was developed. The Quality Assurance Policy established by this manual is to assure that the DUPIC fuel element supplied to customer conform to the specified requirements of customer, applicable codes and standards. The management of KAERI is committed to implementation and maintenance of the program described by this manual. This manual describes the quality assurance program for DUPIC fuel fabrication to comply with CAN3-Z299.2-85 to the extent as needed and appropriate. This manual describes the methods which DUPIC Fuel Development Team(DFDT) personnel must follow to achieve and assure high quality of our product. This manual also describes the quality management system applicable to the activities performed at DFDT

  10. User's manual of Tokamak Simulation Code

    International Nuclear Information System (INIS)

    Nakamura, Yukiharu; Nishino, Tooru; Tsunematsu, Toshihide; Sugihara, Masayoshi.

    1992-12-01

    User's manual for use of Tokamak Simulation Code (TSC), which simulates the time-evolutional process of deformable motion of axisymmetric toroidal plasma, is summarized. For the use at JAERI computer system, the TSC is linked with the data management system GAEA. This manual is forcused on the procedure for the input and output by using the GAEA system. Model equations to give axisymmetric motion, outline of code system, optimal method to get the well converged solution are also described. (author)

  11. Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients.

    Science.gov (United States)

    Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan

    2016-07-27

    The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. The study was conducted at the Be'sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable.

  12. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis

    OpenAIRE

    ?nce, Fatma Demet; Ellida?, Hamit Ya?ar; Koseo?lu, Mehmet; ?im?ek, Ne?e; Yal??n, H?lya; Zengin, Mustafa Osman

    2016-01-01

    Objectives: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. Design and methods: 209 urine samples were analyzed by the Iris iQ200 ELITE (Ä°ris Diagnostics, USA), Dirui...

  13. Washington Manual: A New Tool for Local School Accounting

    Science.gov (United States)

    Federal Aid Planner, 1972

    1972-01-01

    An advance glimpse of the revised financial accounting methods for school districts recommended in a new manual from the U. S. Office of Education. The manual is designed to help school districts modernize their financial accounting procedures and their entire range of fiscal management practices. (Author/DN)

  14. SYVAC3 manual

    International Nuclear Information System (INIS)

    Andres, T.H.

    2000-01-01

    SYVAC3 (Systems Variability Analysis Code, generation 3) is a computer program that implements a method called systems variability analysis to analyze the behaviour of a system in the presence of uncertainty. This method is based on simulating the system many times to determine the variation in behaviour it can exhibit. SYVAC3 specializes in systems representing the transport of contaminants, and has several features to simplify the modelling of such systems. It provides a general tool for estimating environmental impacts from the dispersal of contaminants. This report describes the use and structure of SYVAC3. It is intended for modellers, programmers, operators and reviewers who deal with simulation codes based on SYVAC3. From this manual they can learn how to link a model with SYVAC3, how to set up an input file, and how to extract results from output files. The manual lists the subroutines of SYVAC3 that are available for use by models, and describes their argument lists. It also gives an overview of how routines in the File Reading Package, the Parameter Sampling Package and the Time Series Package can be used by programs outside of SYVAC3. (author)

  15. SYVAC3 manual

    Energy Technology Data Exchange (ETDEWEB)

    Andres, T.H

    2000-07-01

    SYVAC3 (Systems Variability Analysis Code, generation 3) is a computer program that implements a method called systems variability analysis to analyze the behaviour of a system in the presence of uncertainty. This method is based on simulating the system many times to determine the variation in behaviour it can exhibit. SYVAC3 specializes in systems representing the transport of contaminants, and has several features to simplify the modelling of such systems. It provides a general tool for estimating environmental impacts from the dispersal of contaminants. This report describes the use and structure of SYVAC3. It is intended for modellers, programmers, operators and reviewers who deal with simulation codes based on SYVAC3. From this manual they can learn how to link a model with SYVAC3, how to set up an input file, and how to extract results from output files. The manual lists the subroutines of SYVAC3 that are available for use by models, and describes their argument lists. It also gives an overview of how routines in the File Reading Package, the Parameter Sampling Package and the Time Series Package can be used by programs outside of SYVAC3. (author)

  16. Continuing Medical Education - Vol 27, No 1 (2009)

    African Journals Online (AJOL)

    Continuing Medical Education - Vol 27, No 1 (2009). Journal Home > Archives > Vol 27, No 1 (2009). Log in or Register to get access to full text downloads. ... Addiction treatment · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT. R Meyer ...

  17. A background to risk analysis. Vol. 2

    International Nuclear Information System (INIS)

    Taylor, J.R.

    1979-01-01

    This 4-volumes report gives a background of ideas, principles and examples which might be of use in developing practical methods for risk analysis. Some of the risk analysis techniques described are somewhat experimental. The report is written in an introductory style, but where some point needs further justification or evaluation, this is given in the form of a chapter appendix. In this way, it is hoped that the report can serve two purposes, - as a basis for starting risk analysis work and as a basis for discussing effectiveness of risk analysis procedures. The report should be seen as a preliminary stage, prior to a program of industrial trials of risk analysis methods. Vol. 2 treats generic methods of qualitative failure analysis. (BP)

  18. International Journal of Humanistic Studies - Vol 3 (2004)

    African Journals Online (AJOL)

    International Journal of Humanistic Studies - Vol 3 (2004). Journal Home > Archives > Vol 3 (2004). Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives. DOWNLOAD FULL TEXT ...

  19. Manual for soil physical measurements; Version 3

    NARCIS (Netherlands)

    Stolte, J.

    1997-01-01

    Manuals are given for several laboratory methods for determining hydraulic conductivity, water retention and shrinkage characteristics of soil. Measurement techniques described are: the constant-head and falling-head methods for saturated conductivitythe drip infiltrometer for unsaturated

  20. Evaluation of Capacity on a High Throughput Vol-oxidizer for Operability

    International Nuclear Information System (INIS)

    Kim, Young Hwan; Park, Geun Il; Lee, Jung Won; Jung, Jae Hoo; Kim, Ki Ho; Lee, Yong Soon; Lee, Do Youn; Kim, Su Sung

    2010-01-01

    KAERI is developing a pyro-process. As a piece of process equipment, a high throughput vol-oxidizer which can handle a several tens kg HM/batch was developed to supply U 3 O 8 powders to an electrolytic reduction(ER) reactor. To increase the reduction yield, UO 2 pellets should be converted into uniform powders. In this paper, we aim at the evaluation of a high throughput vol-oxidizer for operability. The evaluation consisted of 3 targets, a mechanical motion test, a heating test and hull separation test. In order to test a high throughput vol-oxidizer, By using a control system, mechanical motion tests of the vol-oxidizer were conducted, and heating rates were analyzed. Also the separation tests of hulls for recovery rate were conducted. The test results of the vol-oxidizer are going to be applied for operability. A study on the characteristics of the volatile gas produced during a vol-oxidation process is not included in this study

  1. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    Energy Technology Data Exchange (ETDEWEB)

    Rathbone, Bruce A.

    2010-01-01

    manual by PNNL was discontinued beginning with Revision 0.2. Revision Log: Rev. 0 (2/25/2005) Major revision and expansion. Rev. 0.1 (3/12/2007) Updated Chapters 5, 6 and 9 to reflect change in default ring calibration factor used in HEDP dose calculation software. Factor changed from 1.5 to 2.0 beginning January 1, 2007. Pages on which changes were made are as follows: 5.23, 5.69, 5.78, 5.80, 5.82, 6.3, 6.5, 6.29, and 9.2. Rev 0.2 (8/28/2009) Updated Chapters 3, 5, 6, 8 and 9. Chapters 6 and 8 were significantly expanded. References in the Preface and Chapters 1, 2, 4, and 7 were updated to reflect updates to DOE documents. Approved by HPDAC on 6/2/2009. Rev 1.0 (1/1/2010) Major revision. Updated all chapters to reflect the Hanford site wide implementation on January 1, 2010 of new DOE requirements for occupational radiation protection. The new requirements are given in the June 8, 2007 amendment to 10 CFR 835 Occupational Radiation Protection (Federal Register, June 8, 2007. Title 10 Part 835. U.S., Code of Federal Regulations, Vol. 72, No. 110, 31904-31941). Revision 1.0 to the manual replaces ICRP 26 dosimetry concepts and terminology with ICRP 60 dosimetry concepts and terminology and replaces external dose conversion factors from ICRP 51 with those from ICRP 74 for use in measurement of operational quantities with dosimeters. Descriptions of dose algorithms and dosimeter response characteristics, and field performance were updated to reflect changes in the neutron quality factors used in the measurement of operational quantities.

  2. A comparison study of size-specific dose estimate calculation methods

    Energy Technology Data Exchange (ETDEWEB)

    Parikh, Roshni A. [Rainbow Babies and Children' s Hospital, University Hospitals Cleveland Medical Center, Case Western Reserve University School of Medicine, Department of Radiology, Cleveland, OH (United States); University of Michigan Health System, Department of Radiology, Ann Arbor, MI (United States); Wien, Michael A.; Jordan, David W.; Ciancibello, Leslie; Berlin, Sheila C. [Rainbow Babies and Children' s Hospital, University Hospitals Cleveland Medical Center, Case Western Reserve University School of Medicine, Department of Radiology, Cleveland, OH (United States); Novak, Ronald D. [Rainbow Babies and Children' s Hospital, University Hospitals Cleveland Medical Center, Case Western Reserve University School of Medicine, Department of Radiology, Cleveland, OH (United States); Rebecca D. Considine Research Institute, Children' s Hospital Medical Center of Akron, Center for Mitochondrial Medicine Research, Akron, OH (United States); Klahr, Paul [CT Clinical Science, Philips Healthcare, Highland Heights, OH (United States); Soriano, Stephanie [Rainbow Babies and Children' s Hospital, University Hospitals Cleveland Medical Center, Case Western Reserve University School of Medicine, Department of Radiology, Cleveland, OH (United States); University of Washington, Department of Radiology, Seattle, WA (United States)

    2018-01-15

    The size-specific dose estimate (SSDE) has emerged as an improved metric for use by medical physicists and radiologists for estimating individual patient dose. Several methods of calculating SSDE have been described, ranging from patient thickness or attenuation-based (automated and manual) measurements to weight-based techniques. To compare the accuracy of thickness vs. weight measurement of body size to allow for the calculation of the size-specific dose estimate (SSDE) in pediatric body CT. We retrospectively identified 109 pediatric body CT examinations for SSDE calculation. We examined two automated methods measuring a series of level-specific diameters of the patient's body: method A used the effective diameter and method B used the water-equivalent diameter. Two manual methods measured patient diameter at two predetermined levels: the superior endplate of L2, where body width is typically most thin, and the superior femoral head or iliac crest (for scans that did not include the pelvis), where body width is typically most thick; method C averaged lateral measurements at these two levels from the CT projection scan, and method D averaged lateral and anteroposterior measurements at the same two levels from the axial CT images. Finally, we used body weight to characterize patient size, method E, and compared this with the various other measurement methods. Methods were compared across the entire population as well as by subgroup based on body width. Concordance correlation (ρ{sub c}) between each of the SSDE calculation methods (methods A-E) was greater than 0.92 across the entire population, although the range was wider when analyzed by subgroup (0.42-0.99). When we compared each SSDE measurement method with CTDI{sub vol,} there was poor correlation, ρ{sub c}<0.77, with percentage differences between 20.8% and 51.0%. Automated computer algorithms are accurate and efficient in the calculation of SSDE. Manual methods based on patient thickness provide

  3. Dynamics of structures '89. Vol. 3

    International Nuclear Information System (INIS)

    1989-01-01

    The proceedings, comprising 3 volumes published by the Plzen Centre of the Czechoslovak Society for Science and Technology (Vol. 1 and 2) and by Skoda Works in Plzen (Vol. 3), contain 107 papers, out of which 8 fall within the INIS Subject Scope; these deal with problems related to the earthquake resistance of nuclear power plants. Attention is paid to the evaluation of seismic characteristics of nuclear power plant equipment, to the equipment testing and to calculations of its dynamic characteristics under simulated seismic stress. (Z.M.)

  4. EMSL Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Nancy S.

    2009-06-18

    This manual is a general resource tool to assist EMSL users and Laboratory staff within EMSL locate official policy, practice and subject matter experts. It is not intended to replace or amend any formal Battelle policy or practice. Users of this manual should rely only on Battelle’s Standard Based Management System (SBMS) for official policy. No contractual commitment or right of any kind is created by this manual. Battelle management reserves the right to alter, change, or delete any information contained within this manual without prior notice.

  5. EMSL Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Foster, Nancy S.

    2009-03-25

    This manual is a general resource tool to assist EMSL users and Laboratory staff within EMSL locate official policy, practice and subject matter experts. It is not intended to replace or amend any formal Battelle policy or practice. Users of this manual should rely only on Battelle’s Standard Based Management System (SBMS) for official policy. No contractual commitment or right of any kind is created by this manual. Battelle management reserves the right to alter, change, or delete any information contained within this manual without prior notice.

  6. [Manual lifting and manual transport: risk assessment and prevalence of work-related diseases in construction companies in Basilicata].

    Science.gov (United States)

    Nicoletti, S; Battevi, N; Colafemmina, G; Di Leone, G; Satriani, G; Ragone, P; Occhipinti, E

    2013-01-01

    The Basilicata Regional Headquarters of the Italian Institute for Insurance against Occupational Accidents and Disease (INAIL) and the Basilicata association of small building enterprises (Edilcassa di Basilicata) promoted a research project to assess the risk of manual lifting and manual transport in construction enterprises in the Basilicata Region and estimate the prevalence of related diseases. Manual lifting risk assessment was performed by calculating the VLI of 204 working days in as many building workers. Manual transport risk assessment was carried out comparing the weights transported (on the 204 days tested) with the reference values of the "Snoock and Ciriello" tables. Manual Ifting risk was present on 195 of the 204 days, with an average value of VLI equal to 2.1 (min 0.4, max 8.5), with higher values in the restructuring sector (VLI average of 2.3, min 0.4, max 8.5), and no significant differences between the different tasks. Manual transport risk was present on 129 of the 204 days, with average values of 1.2 (min 0.2, max 3.3), with no significant differences between the different tasks analyzed For both risks additional factors were present that were not analyzed by the methods of assessment used (for manual lifting: 8.8% of the geometries in the critical area; for manual transport: 39% of transport on shoulders, 42.5% on a route with uneven surface and 31.9% on a sloping route), so it is likely that the actual risk is greater than that indicated by the synthetic indices of exposure. The medical questionnaire showed from the case histories that 148 out of 546 subjects were positive for the threshold forpain or discomfort in the lumbosacral spine area and 99 out of 546 subjects reported suffering from an already diagnosed herniated spinal disk. Only 18% of osteoarticular diseases was reported to the Insurance Institute, al though there was widespread awareness that the diseases in question might be related to work. Diseases of the spine were

  7. Application work risk of manual material handling operators using different lifting methods

    Science.gov (United States)

    Anizar; Matondang, AR; Sibarani, JA

    2018-02-01

    This study observed the activity of lifting and moving crates containing bottles at a pallet station in a carbonated drink factory. The activity of moving crates, each weighing 15 kg, is performed by four operators using different methods. An operator manually moves 250 crates daily and often takes rest during working. This study aims to find the most efficient method, that is using the least energy, to move crates. The workload is assessed using the method of Cardiovascular Strain Load (CVL) and energy expenditure. Operators’ arterial pulse is measured for 1 minute right before they start working and after they finish working; this is done to obtain work arterial pulse and rest arterial pulse. The way operators lift crates is analyzed using biomechanics. It is found that fatigue is experienced by all operators, with the exception of the 3rd operator who has a %CVL number below 30%. He positions the pallet to be parallel to the conveyor, and then stand in between during the lifting process. He only rotates his body to move the crate from the conveyor onto the pallet, requiring only little energy. This is one of the reasons why the %CVL number is lower than the other operators.

  8. Factors associated with high physical exertion during manual lifting

    DEFF Research Database (Denmark)

    Andersen, Lars L.; Sundstrup, Emil; Brandt, Mikkel

    2018-01-01

    BACKGROUND: High physical exertion during work is a risk factor for back pain and long-term sickness absence. OBJECTIVE: To investigate which factors are associated with physical exertion during manual lifting. METHODS: From 14 workplaces across Denmark, 200 blue-collar workers reported perceived...... physical exertion (Borg-CR10) during manual lifting from floor to table height of 5, 10, 20 and 30 kg at the beginning and end of the working day. The workers also responded to a questionnaire and went through testing of isometric back muscle strength. Associations were modelled using logistic regression...... during manual lifting in blue-collar workers. These factors should be considered when planning work with manual lifting for individual workers....

  9. Assessing symmetry using the mirror stand device with manual and software-assisted methods in postoperative zygomatic fracture patients

    Science.gov (United States)

    Syarif, A. N.; Bangun, K.

    2017-08-01

    Zygomatic fractures are among the most common fractures to the facial skeleton. However, because no standard and reliable method of evaluation is available to assess postoperative patients, we often rely on photographs and subjective assessments. A portable mirror stand device (MiRS), which is a new method for the standardization of photography, was developed in our institution. Used with image analysis software, this device provides a new method for evaluating outcomes after the open reduction and internal fixation of zygomatic fractures. The portable mirror stand device was set up in our outpatient clinic at the Cleft Craniofacial Center at Cipto Mangunkusumo Hospital. Photographs of 11 postoperative patients were taken using the device, and they were analyzed both manually and using image analysis software (ImageJ 1.46) for symmetry. The two methods were then compared to assess the correlation and agreement of the results. The measurements taken using the manual method and the software-assisted method did not differ significantly, which indicated the good agreement between the two methods. The results of the symmetry achieved atour center were similar to other centers in the Asian region (ΔZy = 3.4±1.5 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.4 mm) compared with (ΔZy = 3.2±1.7 mm, ΔBc = 2.6±1.6 mm, ΔCh = 2.3±2.5 mm). The treatment of zygomatic fracture a tour center achieved good results. The portable mirror stand device assisted the image analysis software (ImageJ 1.46), which could be beneficial in assessing symmetry in postoperative zygomatic fracture patients.

  10. INTRA/Mod3.2. Manual and code description. Volume 2 - User's manual

    International Nuclear Information System (INIS)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the physical modelling of INTRA and the ruling numerics, and volume II, the User's Manual is an input description. This document, the User's Manual, Volume II, contains a detailed description of how to use INTRA, how to set up an input file, how to run INTRA and also post-processing

  11. Structures manual

    Science.gov (United States)

    2001-01-01

    This manual was written as a guide for use by design personnel in the Vermont Agency of Transportation Structures Section. This manual covers the design responsibilities of the Section. It does not cover other functions that are a part of the Structu...

  12. Ciencias 2. Manual do Professor (Science Teacher's Manual).

    Science.gov (United States)

    Raposo, Lucilia

    This is the teacher's manual for Ciencias 2, the second in a series of elementary science textbooks for Portuguese-speaking students. The student textbook contains 10 chapters and 57 activities. The teacher's manual presents an explanation of the educational goals and the organization of the content, Topics included are environment, the human,…

  13. Radiological Control Manual

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  14. Radiological Control Manual

    International Nuclear Information System (INIS)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records

  15. Egyptian Mythological Manuals

    DEFF Research Database (Denmark)

    Jørgensen, Jens Kristoffer Blach

    From the hands of Greek mythographers a great number of myths have survived along with philosophical discussions of their meaning and relevance for the Greeks. It is little known that something similar existed in ancient Egypt where temple libraries and archives held scholarly literature used...... by the native priesthood, much of which has only been published in recent years. As part of this corpus of texts, the ancient Egyptian mythological manuals offer a unique perspective on how the Egyptian priesthood structured and interpreted Egyptian myths. The thesis looks at the different interpretative...... techniques used in the Tebtunis Mythological Manual (Second century CE) and the Mythological Manual of the Delta (Sixth century BCE) and the place of these manuals within the larger corpus of priestly scholarly literature from ancient Egypt. To organize the wealth of local myths the manuals use model...

  16. Prediction method for the lubricating oil temperature of manual transaxle; Manual transaxle no yuon yosoku simulation

    Energy Technology Data Exchange (ETDEWEB)

    Iritani, M; Kaneda, K; Ibaraki, K [Toyota Central Research and Development Labs., Inc., Aichi (Japan); Suzuki, K; Morita, Y [Toyota Motor Corp., Aichi (Japan)

    1997-10-01

    Heat transfer and flow characteristics in manual transaxle (MT) are not clear. The measurement of the heat flux and the heat generations and the flow visualization were conducted for quantitative analysis of the heat transfer phenomena in the MT. A simulating technique for the lubricant temperature was developed with these experimental data and the prediction accuracy was within 3degC under the various operating conditions. The simulation was verified to be useful for estimating the lubricant temperature reduction by the lubricant volume reduction, air flow improvement around MT, etc. 7 refs., 8 figs.

  17. Endovascular Treatment of Phlegmasia Cerulea Dolens with Impending Venous Gangrene: Manual Aspiration Thrombectomy as the First-Line Thrombus Removal Method

    International Nuclear Information System (INIS)

    Oguzkurt, Levent; Ozkan, Ugur; Demirturk, Orhan S.; Gur, Serkan

    2011-01-01

    Purpose: Our purpose was to report the outcome of endovascular treatment with manual aspiration thrombectomy as the first-line thromboablative method for phlegmasia cerulea dolens. Methods: Between October 2006 and May 2010, seven consecutive patients (5 women, 2 men; age range, 31–80 years) with the diagnosis of phlegmasia cerulea dolens secondary to acute iliofemoral deep venous thrombosis had endovascular treatment with manual aspiration thrombectomy. Catheter-directed thrombolysis and stent placement were used as adjunctive procedures. Phlegmasia was left-sided in five and right-sided in two patients. Results: All patients had associated great saphenous vein thrombosis in addition to iliofemoral deep vein thrombosis (DVT). Aspiration thrombectomy completely removed the thrombus from the popliteal vein to the inferior vena cava (IVC) in all cases. Three patients with May-Thurner syndrome had stent placement in the left common iliac vein. Two patients had early recurrences. Repeated aspiration thrombectomy was unsuccessful in one patient. There were no complications related to the procedure. One patient who had been successfully treated died of sepsis and another patient who had unsuccessful repeated interventions had below-the-knee amputation. Overall, the clinical success and survival rates of patients in this study were 86%. On follow-up, three patients with successful treatment were asymptomatic with no deep venous insufficiency. One of these patients died during the 4-month follow-up period. Two patients had mild ankle swelling with deep venous insufficiency. Conclusions: Manual aspiration thrombectomy with adjunctive use of catheter-directed thrombolysis and stent placement is an effective endovascular treatment method with high clinical success and survival rates for phlegmasia cerulean dolens.

  18. Hippocampal volume change measurement: Quantitative assessment of the reproducibility of expert manual outlining and the automated methods FreeSurfer and FIRST

    NARCIS (Netherlands)

    Mulder, E.R.; de Jong, R.A.; Knol, D.L.; van Schijndel, R.A.; Cover, K.S.; Visser, P.J.; Barkhof, F.; Vrenken, H.

    2014-01-01

    Background: To measure hippocampal volume change in Alzheimer's disease (AD) or mild cognitive impairment (MCI), expert manual delineation is often used because of its supposed accuracy. It has been suggested that expert outlining yields poorer reproducibility as compared to automated methods, but

  19. Faktor Risiko Manual Handling dengan Keluhan Nyeri Punggung Bawah Pembuat Batu Bata

    Directory of Open Access Journals (Sweden)

    Heru Subaris Kasjono

    2017-08-01

    Full Text Available During done manual work handling for objects work hard, it will cause risk of injury or cause musculoskeletal systems. Risk assessment manual work handling with the methods indicators key-Leitmerkmal Method (LMM intended to know the relationship between time, burden, attitudes of the body, and working conditions manual handling with complaints of the lower back pain at all stages making bricks perceived maker bricks. The kind of research used is surveyed such data is cross sectional. The data taken by lower back pain questionnaire assisted examination physically by nurses and checklist Key-LMM. Analysis relations use the spearman. The results of research acquired at variable time manual handling based frequency raised or operation the transfer of on stage excavation raw materials, the formation and drying bricks there are relations with complaints of  low back pain with p value each are 0,039, 0,047, 0,038 while on the variables of working conditions manual handling in stage excavation raw materials obtained p value of 0,028 with so it can be said there was a correlation between working conditions manual handling with complaints low back pain. A variable load manual handling and attitudes of the body manual handling do not relate in significant to lower back pain all stages making bricks. Conclusion researchers that the variable time manual handling relate in significant with complaints lower back pain in stage excavation raw materials, the formation and drying bricks, while the phase processing raw materials that there was no correlation, in a variable load manual handling and attitudes of the body manual handling all these stage there was no correlation with complaints lower back pain, while variable working conditions manual handling only in stage excavation the raw materials there are relations with complaints lower back pain in the third stage other there was no correlation.

  20. Vol 41 No 2

    African Journals Online (AJOL)

    Esem

    3 Centre for Primary Care Research. Medical Journal of Zambia, Vol. 41, No. 2: 59 - 64 (2014) ... pollutants by inhaling second-hand tobacco smoke are at risk of adverse health ..... To put the measured PM levels into perspective, a. 2.5. 5.

  1. 12-EEASA-Vol 22.indd

    African Journals Online (AJOL)

    jenny

    2006-02-22

    Feb 22, 2006 ... Southern African Journal of Environmental Education, Vol. .... To this end, a planning conference on environmental .... mathematics, physics, chemistry, biology, geography, agriculture, home economics and human and.

  2. Journal of EEA, Vol. 27, 2010 COMPUTATIONALLY EFFICIENT ...

    African Journals Online (AJOL)

    CBC

    using a commercial structural analysis software system. .... In Eqs. (1), Ax and Iz.x represent the cross-sectional area and ... common types for the setup of analysis equations; these are ..... manual calculations based on the Cross method of.

  3. Manual for reactor produced radioisotopes

    International Nuclear Information System (INIS)

    2003-01-01

    Radioisotopes find extensive applications in several fields including medicine, industry, agriculture and research. Radioisotope production to service different sectors of economic significance constitutes an important ongoing activity of many national nuclear programmes. Radioisotopes, formed by nuclear reactions on targets in a reactor or cyclotron, require further processing in almost all cases to obtain them in a form suitable for use. Specifications for final products and testing procedures for ensuring quality are also an essential part of a radioisotope production programme. The International Atomic Energy Agency (IAEA) has compiled and published such information before for the benefit of laboratories of Member States. The first compilation, entitled Manual of Radioisotope Production, was published in 1966 (Technical Reports Series No. 63). A more elaborate and comprehensive compilation, entitled Radioisotope Production and Quality Control, was published in 1971 (Technical Reports Series No. 128). Both served as useful reference sources for scientists working in radioisotope production worldwide. The 1971 publication has been out of print for quite some time. The IAEA convened a consultants meeting to consider the need for compiling an updated manual. The consultants recommended the publication of an updated manual taking the following into consideration: significant changes have taken place since 1971 in many aspects of radioisotope production; many radioisotopes have been newly introduced while many others have become gradually obsolete; considerable experience and knowledge have been gained in production of important radioisotopes over the years, which can be preserved through compilation of the manual; there is still a need for a comprehensive manual on radioisotope production methods for new entrants to the field, and as a reference. It was also felt that updating all the subjects covered in the 1971 manual at a time may not be practical considering the

  4. Métodos de extrusão manual e elétrica dos espermat��foros de reprodutores selvagens do camarão-rosa Farfantepenaeus paulensis (Decapoda: Penaeidae Manual and electrical spermatophore extrusion methods of the pink shrimp Farfantepenaeus paulensis (Decapoda: Penaeidae wild broodstock

    Directory of Open Access Journals (Sweden)

    Cintia Nakayama

    2008-10-01

    Full Text Available O presente estudo comparou os métodos manual e elétrico de extrusão do espermatóforo do camarão-rosa Farfantepenaeus paulensis com o objetivo de verificar se os métodos de extrusão exercem influência na quantidade de células espermáticas e na regeneração de novos espermatóforos. Os machos foram extrusados no início (dia zero e no final do experimento (dia 43 para verificação da eficiência dos métodos no processo de regeneração. A extrusão manual foi realizada por meio de pressão na região do quinto par de pereiópodos e o método elétrico com uso de eletrodo para transmissão de impulso elétrico de 9 volts na mesma região. Os dois métodos foram considerados eficientes, não sendo encontradas diferenças significativas entre estes (P>0,05 para o número de células espermáticas. Entretanto, foi verificada, no final do experimento, a perda de peso corporal, peso de espermatóforo e menor índice espermatossomático (IES (PThe present study compared manual and electrical methods to extrude the spermatophore of the pink shrimp Farfantepenaeus paulensis aiming to analyze their influence on the number of spermatic cells and spermatophore regeneration. The males were extruded in the beginning (day zero and in the end (43rd day of the experiment to evaluate the efficiency of these methods in the regeneration process. For the extrusion, a gentle pressure was applied manually in the fifth pair of pereiopods or electrically by a 9 volt pulse in the same area. Both methods were efficient in removing the spermatophore and no significant differences were found (P>0.05 in the number of sperm cells. Nevertheless, significant decreases (P<0.05 in the body weight, spermatophore weight and spermatosomatic index (ESI at the end of the experimental period were observed by using the electrical stimulation. The mean values (±SD of the number of sperm cells were 1.46 (±0.84 and 3.25 (±2.12 millions for the electrical and manual treatments

  5. A background to risk analysis. Vol. 4

    International Nuclear Information System (INIS)

    Taylor, J.R.

    1979-01-01

    This 4-volumes report gives a background of ideas, principles, and examples which might be of use in developing practical methods for risk analysis. Some of the risk analysis techniques described are somewhat experimental. The report is written in an introductory style, but where some point needs further justification or evaluation, this is given in the form of a chapter appendix. In this way, it is hoped that the report can serve two purposes, - as a basis for starting risk analysis work and as a basis for discussing effectiveness of risk analysis procedures. The report should be seen as a preliminary stage, prior to a program of industrial trials of risk analysis methods. Vol. 4 treats human error in plant operation. (BP)

  6. INTRA/Mod3.2. Manual and code description. Volume 2 - User`s manual

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, Jenny; Edlund, O.; Hermann, J.; Johansson, Lise-Lotte

    1999-01-01

    The INTRA Manual consists of two volumes. Volume I of the manual is a thorough description of the code INTRA, the physical modelling of INTRA and the ruling numerics, and volume II, the User`s Manual is an input description. This document, the User`s Manual, Volume II, contains a detailed description of how to use INTRA, how to set up an input file, how to run INTRA and also post-processing

  7. Index to Nuclear Safety. A technical progress review by chronology, permuted title, and author. Vol. 11, No. 1 through Vol. 15, No. 6

    International Nuclear Information System (INIS)

    Cottrell, W.B.; Klein, A.

    1975-04-01

    This issue of the Index to Nuclear Safety covers only articles included in Nuclear Safety, Vol. 11, No. 1, through Vol. 15, No. 6. This index is presented in three sections as follows: Chronological List of Articles by Volume; Permuted Title (KWIC) Index; and Author Index. (U.S.)

  8. Economic and Policy Review - Vol 13, No 3 (2007)

    African Journals Online (AJOL)

    Economic and Policy Review - Vol 13, No 3 (2007). Journal Home > Archives > Vol 13, No 3 ... Snagging the wheel of progress: Corruption, New anti-corruption drive and Nigeria\\'s quest for development. S B Kura ... Book Review: challenges of African growth opportunities, constraints and strategic directions. S I Owualah ...

  9. A background risk analysis. Vol. 1

    International Nuclear Information System (INIS)

    Taylor, J.R.

    1979-01-01

    This 4-volumes report gives a background of ideas, principles, and examples which might be of use in developing practical methods for risk analysis. Some of the risk analysis techniques, described are somewhat experimental. The report is written in an introductory style, but where some point needs further justification or evaluation, this is given in the form of a chapter appendix. In this way, it is hoped that the report can serve two purposes, - as a basis for starting risk analysis work and as a basis for discussing effectiveness of risk analysis procedures. The report should be seen as a preliminary stage, prior to a program of industrial trials of risk analysis methods. Vol. 1 contains a short history of risk analysis, and chapters on risk, failures, errors and accidents, and general procedures for risk analysis. (BP)

  10. Stirling engine design manual, 2nd edition

    Science.gov (United States)

    Martini, W. R.

    1983-01-01

    This manual is intended to serve as an introduction to Stirling cycle heat engines, as a key to the available literature on Stirling engines and to identify nonproprietary Stirling engine design methodologies. Two different fully described Stirling engines are discussed. Engine design methods are categorized as first order, second order, and third order with increased order number indicating increased complexity. FORTRAN programs are listed for both an isothermal second order design program and an adiabatic second order design program. Third order methods are explained and enumerated. In this second edition of the manual the references are updated. A revised personal and corporate author index is given and an expanded directory lists over 80 individuals and companies active in Stirling engines.

  11. A student manual for promoting mental health among high school students

    Directory of Open Access Journals (Sweden)

    Antonella Gigantesco

    2013-03-01

    Full Text Available OBJECTIVES. We describe a school program based on a student manual for promoting mental health and preventing mental illness. METHODS. A preliminary version of the manual was assessed for face validity by two focus groups. The final version was evaluated for acceptability among 253 students in 10 high schools and 1 middle school in Italy. RESULTS. The manual included 18 chapters (or "units" which address skills for enabling students to cope with their daily lives: communication skills, problem-solving, assertive skills, negotiation, stress management, anger management and conflict resolution. The manual was found to have been acceptable by high school students. CONCLUSIONS. The effectiveness of the manual in actually promoting mental health and preventing mental illness is currently being evaluated.

  12. Amnesic Shellfish Poisoning (ASP)

    DEFF Research Database (Denmark)

    Ravn, H.

    HAB Publ. Ser. vol 1 is a supplement to Chapter 7 Mehtods for Domoic Acid, the Amnesic Shellfish Poisons in the IOC Manual of Harmful Marine Microalgae......HAB Publ. Ser. vol 1 is a supplement to Chapter 7 Mehtods for Domoic Acid, the Amnesic Shellfish Poisons in the IOC Manual of Harmful Marine Microalgae...

  13. Camp Health Aide Manual = Manual para trabajadores de salud.

    Science.gov (United States)

    Robinson, June Grube; And Others

    This bilingual manual serves as a textbook for migrant Camp Health Aides. Camp Health Aides are members of migrant labor camps enlisted to provide information about health and social services to migrant workers and their families. The manual is divided into 12 tabbed sections representing lessons. Teaching notes printed on contrasting paper…

  14. Zede Journal - Vol 29 (2012)

    African Journals Online (AJOL)

    Journal Home > Archives > Vol 29 (2012) ... Leakage aware hardware and stochastic power scheduling for smart mobile devices ... Energy efficient topology for Wireless Mesh Networks · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  15. Department of the Army Cost Analysis Manual

    National Research Council Canada - National Science Library

    1997-01-01

    .... The specific goal of this manual is to help the cost analyst serve the customer. This is done by providing reference material on cost analysis processes, methods, techniques, structures, and definitions...

  16. A Manual of Style.

    Science.gov (United States)

    Nebraska State Dept. of Education, Lincoln.

    This "Manual of Style" is offered as a guide to assist Nebraska State employees in producing quality written communications and in presenting a consistently professional image of government documents. The manual is not designed to be all-inclusive. Sections of the manual discuss formatting documents, memorandums, letters, mailing…

  17. ARDS User Manual

    Science.gov (United States)

    Fleming, David P.

    2001-01-01

    Personal computers (PCs) are now used extensively for engineering analysis. their capability exceeds that of mainframe computers of only a few years ago. Programs originally written for mainframes have been ported to PCs to make their use easier. One of these programs is ARDS (Analysis of Rotor Dynamic Systems) which was developed at Arizona State University (ASU) by Nelson et al. to quickly and accurately analyze rotor steady state and transient response using the method of component mode synthesis. The original ARDS program was ported to the PC in 1995. Several extensions were made at ASU to increase the capability of mainframe ARDS. These extensions have also been incorporated into the PC version of ARDS. Each mainframe extension had its own user manual generally covering only that extension. Thus to exploit the full capability of ARDS required a large set of user manuals. Moreover, necessary changes and enhancements for PC ARDS were undocumented. The present document is intended to remedy those problems by combining all pertinent information needed for the use of PC ARDS into one volume.

  18. Quality Manual

    Science.gov (United States)

    Koch, Michael

    The quality manual is the “heart” of every management system related to quality. Quality assurance in analytical laboratories is most frequently linked with ISO/IEC 17025, which lists the standard requirements for a quality manual. In this chapter examples are used to demonstrate, how these requirements can be met. But, certainly, there are many other ways to do this.

  19. Automatic and manual segmentation of healthy retinas using high-definition optical coherence tomography.

    Science.gov (United States)

    Golbaz, Isabelle; Ahlers, Christian; Goesseringer, Nina; Stock, Geraldine; Geitzenauer, Wolfgang; Prünte, Christian; Schmidt-Erfurth, Ursula Margarethe

    2011-03-01

    This study compared automatic- and manual segmentation modalities in the retina of healthy eyes using high-definition optical coherence tomography (HD-OCT). Twenty retinas in 20 healthy individuals were examined using an HD-OCT system (Carl Zeiss Meditec, Inc.). Three-dimensional imaging was performed with an axial resolution of 6 μm at a maximum scanning speed of 25,000 A-scans/second. Volumes of 6 × 6 × 2 mm were scanned. Scans were analysed using a matlab-based algorithm and a manual segmentation software system (3D-Doctor). The volume values calculated by the two methods were compared. Statistical analysis revealed a high correlation between automatic and manual modes of segmentation. The automatic mode of measuring retinal volume and the corresponding three-dimensional images provided similar results to the manual segmentation procedure. Both methods were able to visualize retinal and subretinal features accurately. This study compared two methods of assessing retinal volume using HD-OCT scans in healthy retinas. Both methods were able to provide realistic volumetric data when applied to raster scan sets. Manual segmentation methods represent an adequate tool with which to control automated processes and to identify clinically relevant structures, whereas automatic procedures will be needed to obtain data in larger patient populations. © 2009 The Authors. Journal compilation © 2009 Acta Ophthalmol.

  20. Comparison of automated and manual shielding block fabrication

    International Nuclear Information System (INIS)

    Weeks, K.J.; Fraass, B.A.; McShan, D.L.; Hardybala, S.S.; Hargreaves, E.A.; Lichter, A.S.

    1989-01-01

    This work reports the results of a study comparing computer controlled and manual shielding block cutting. The general problems inherent in automated block cutting have been identified and minimized. A system whose accuracy is sufficient for clinical applications has been developed. The relative accuracy of our automated system versus experienced technician controlled cutting was investigated. In general, it is found that automated cutting is somewhat faster and more accurate than manual cutting for very large fields, but that the reverse is true for most smaller fields. The relative cost effectiveness of automated cutting is dependent on the percentage of computer designed blocks which are generated in the clinical setting. At the present time, the traditional manual method is still favored

  1. Inter-arch digital model vs. manual cast measurements: Accuracy and reliability.

    Science.gov (United States)

    Kiviahde, Heikki; Bukovac, Lea; Jussila, Päivi; Pesonen, Paula; Sipilä, Kirsi; Raustia, Aune; Pirttiniemi, Pertti

    2017-06-28

    The purpose of this study was to evaluate the accuracy and reliability of inter-arch measurements using digital dental models and conventional dental casts. Thirty sets of dental casts with permanent dentition were examined. Manual measurements were done with a digital caliper directly on the dental casts, and digital measurements were made on 3D models by two independent examiners. Intra-class correlation coefficients (ICC), a paired sample t-test or Wilcoxon signed-rank test, and Bland-Altman plots were used to evaluate intra- and inter-examiner error and to determine the accuracy and reliability of the measurements. The ICC values were generally good for manual and excellent for digital measurements. The Bland-Altman plots of all the measurements showed good agreement between the manual and digital methods and excellent inter-examiner agreement using the digital method. Inter-arch occlusal measurements on digital models are accurate and reliable and are superior to manual measurements.

  2. Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients

    OpenAIRE

    Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan

    2016-01-01

    Aim: The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. Material and Methods: The study was conducted at the Be?sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Results: Our results showed that there is a significant...

  3. Battery Test Manual For 48 Volt Mild Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Lee Kenneth [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-03-01

    This manual details the U.S. Advanced Battery Consortium and U.S. Department of Energy Vehicle Technologies Program goals, test methods, and analysis techniques for a 48 Volt Mild Hybrid Electric Vehicle system. The test methods are outlined stating with characterization tests, followed by life tests. The final section details standardized analysis techniques for 48 V systems that allow for the comparison of different programs that use this manual. An example test plan is included, along with guidance to filling in gap table numbers.

  4. Battery Test Manual For 48 Volt Mild Hybrid Electric Vehicles

    International Nuclear Information System (INIS)

    Walker, Lee Kenneth

    2017-01-01

    This manual details the U.S. Advanced Battery Consortium and U.S. Department of Energy Vehicle Technologies Program goals, test methods, and analysis techniques for a 48 Volt Mild Hybrid Electric Vehicle system. The test methods are outlined stating with characterization tests, followed by life tests. The final section details standardized analysis techniques for 48 V systems that allow for the comparison of different programs that use this manual. An example test plan is included, along with guidance to filling in gap table numbers.

  5. SHARP User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Y. Q. [Argonne National Lab. (ANL), Argonne, IL (United States); Shemon, E. R. [Argonne National Lab. (ANL), Argonne, IL (United States); Thomas, J. W. [Argonne National Lab. (ANL), Argonne, IL (United States); Mahadevan, Vijay S. [Argonne National Lab. (ANL), Argonne, IL (United States); Rahaman, Ronald O. [Argonne National Lab. (ANL), Argonne, IL (United States); Solberg, Jerome [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-03-31

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

  6. SHARP User Manual

    International Nuclear Information System (INIS)

    Yu, Y. Q.; Shemon, E. R.; Thomas, J. W.; Mahadevan, Vijay S.; Rahaman, Ronald O.; Solberg, Jerome

    2016-01-01

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

  7. samaru-main-vol 11 2011

    African Journals Online (AJOL)

    Library _info_Sc_ 1

    2004-07-11

    Jul 11, 2004 ... Samaru Journal of Information Studies Vol. 11 (1 & 2)2011 ... It is therefore paramount that the library ... source of primary and up to date information, both students and ... entertainment, arts, fashion, law, economy, medicine,.

  8. ANOPP2 User's Manual: Version 1.2

    Science.gov (United States)

    Lopes, L. V.; Burley, C. L.

    2016-01-01

    This manual documents the Aircraft NOise Prediction Program 2 (ANOPP2). ANOPP2 is a toolkit that includes a framework, noise prediction methods, and peripheral software to aid a user in predicting and understanding aircraft noise. This manual includes an explanation of the overall design and structure of ANOPP2, including a brief introduction to aircraft noise prediction and the ANOPP2 background, philosophy, and architecture. The concept of nested acoustic data surfaces and its application to a mixed-fidelity noise prediction are presented. The structure and usage of ANOPP2, which includes the communication between the user, the ANOPP2 framework, and noise prediction methods, are presented for two scenarios: wind-tunnel and flight. These scenarios serve to provide the user with guidance and documentation references for performing a noise prediction using ANOPP2.

  9. Creating strategic brand management manual : Case: Tukikallio Oy

    OpenAIRE

    Vepsäläinen, Sini

    2010-01-01

    The purpose of this Thesis was to create a Strategic Brand Management Manual for the use of a new company called Tukikallio Oy. The manual was composed of the elements that the company wanted to include in it. A qualitative research method was used in collecting information. The theoretical part of the thesis includes theories about brand building. Brand identity tells what the brand really is with its positive and negative sides, image reflects on what kind of things the consumer associa...

  10. Validating new software for semiautomated liver volumetry. Better than manual measurement?

    Energy Technology Data Exchange (ETDEWEB)

    Noschinski, L.E.; Maiwald, B.; Voigt, P.; Kahn, T.; Stumpp, P. [University Hospital Leipzig (Germany). Dept. of Diagnostic and Interventional Radiology; Wiltberger, G. [University Hospital Leipzig (Germany). Dept. of Visceral, Transplantation, Thoracic and Vascular Surgery

    2015-09-15

    This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33 % vs. 57 %, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience.

  11. Validating new software for semiautomated liver volumetry. Better than manual measurement?

    International Nuclear Information System (INIS)

    Noschinski, L.E.; Maiwald, B.; Voigt, P.; Kahn, T.; Stumpp, P.; Wiltberger, G.

    2015-01-01

    This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33 % vs. 57 %, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience.

  12. Vol 12, No 1 (2014)

    African Journals Online (AJOL)

    Egyptian Journal of Pediatric Allergy and Immunology (The) - Vol 12, No 1 (2014) ... The effect of serum angiotensin II and angiotensin II type 1 receptor gene ... with diabetic ketoacidosis · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  13. Evaluation of manual and automatic manually triggered ventilation performance and ergonomics using a simulation model.

    Science.gov (United States)

    Marjanovic, Nicolas; Le Floch, Soizig; Jaffrelot, Morgan; L'Her, Erwan

    2014-05-01

    In the absence of endotracheal intubation, the manual bag-valve-mask (BVM) is the most frequently used ventilation technique during resuscitation. The efficiency of other devices has been poorly studied. The bench-test study described here was designed to evaluate the effectiveness of an automatic, manually triggered system, and to compare it with manual BVM ventilation. A respiratory system bench model was assembled using a lung simulator connected to a manikin to simulate a patient with unprotected airways. Fifty health-care providers from different professional groups (emergency physicians, residents, advanced paramedics, nurses, and paramedics; n = 10 per group) evaluated manual BVM ventilation, and compared it with an automatic manually triggered device (EasyCPR). Three pathological situations were simulated (restrictive, obstructive, normal). Standard ventilation parameters were recorded; the ergonomics of the system were assessed by the health-care professionals using a standard numerical scale once the recordings were completed. The tidal volume fell within the standard range (400-600 mL) for 25.6% of breaths (0.6-45 breaths) using manual BVM ventilation, and for 28.6% of breaths (0.3-80 breaths) using the automatic manually triggered device (EasyCPR) (P < .0002). Peak inspiratory airway pressure was lower using the automatic manually triggered device (EasyCPR) (10.6 ± 5 vs 15.9 ± 10 cm H2O, P < .001). The ventilation rate fell consistently within the guidelines, in the case of the automatic manually triggered device (EasyCPR) only (10.3 ± 2 vs 17.6 ± 6, P < .001). Significant pulmonary overdistention was observed when using the manual BVM device during the normal and obstructive sequences. The nurses and paramedics considered the ergonomics of the automatic manually triggered device (EasyCPR) to be better than those of the manual device. The use of an automatic manually triggered device may improve ventilation efficiency and decrease the risk of

  14. Manual versus mechanical cardiopulmonary resuscitation. An experimental study in pigs

    Directory of Open Access Journals (Sweden)

    Wohlfart Björn

    2010-10-01

    Full Text Available Abstract Background Optimal manual closed chest compressions are difficult to give. A mechanical compression/decompression device, named LUCAS, is programmed to give compression according to the latest international guidelines (2005 for cardiopulmonary resuscitation (CPR. The aim of the present study was to compare manual CPR with LUCAS-CPR. Methods 30 kg pigs were anesthetized and intubated. After a base-line period and five minutes of ventricular fibrillation, manual CPR (n = 8 or LUCAS-CPR (n = 8 was started and run for 20 minutes. Professional paramedics gave manual chest compression's alternating in 2-minute periods. Ventilation, one breath for each 10 compressions, was given to all animals. Defibrillation and, if needed, adrenaline were given to obtain a return of spontaneous circulation (ROSC. Results The mean coronary perfusion pressure was significantly (p Conclusions LUCAS-CPR gave significantly higher coronary perfusion pressure and significantly fewer rib fractures than manual CPR in this porcine model.

  15. Fuel Element Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Burley, H.H. [ed.

    1956-08-01

    It is the purpose of the Fuel Element Technical Manual to Provide a single document describing the fabrication processes used in the manufacture of the fuel element as well as the technical bases for these processes. The manual will be instrumental in the indoctrination of personnel new to the field and will provide a single data reference for all personnel involved in the design or manufacture of the fuel element. The material contained in this manual was assembled by members of the Engineering Department and the Manufacturing Department at the Hanford Atomic Products Operation between the dates October, 1955 and June, 1956. Arrangement of the manual. The manual is divided into six parts: Part I--introduction; Part II--technical bases; Part III--process; Part IV--plant and equipment; Part V--process control and improvement; and VI--safety.

  16. Non-precision approach in manual mode

    Directory of Open Access Journals (Sweden)

    М. В. Коршунов

    2013-07-01

    Full Text Available Considered is the method of non-precision approach of an aircraft in the manual mode with a constant angle of path. Advantage of this method consists in the fact that the construction of approach with a constant angle of path provides the stable path of flight. It is also considered a detailed analysis of the possibility of the approach by the above-mentioned method. Conclusions contain recommendations regarding the use of the described method of non-precision approach during training flights.

  17. Radiological control manual. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Kloepping, R.

    1996-05-01

    This Lawrence Berkeley National Laboratory Radiological Control Manual (LBNL RCM) has been prepared to provide guidance for site-specific additions, supplements and interpretation of the DOE Radiological Control Manual. The guidance provided in this manual is one methodology to implement the requirements given in Title 10 Code of Federal Regulations Part 835 (10 CFR 835) and the DOE Radiological Control Manual. Information given in this manual is also intended to provide demonstration of compliance to specific requirements in 10 CFR 835. The LBNL RCM (Publication 3113) and LBNL Health and Safety Manual Publication-3000 form the technical basis for the LBNL RPP and will be revised as necessary to ensure that current requirements from Rules and Orders are represented. The LBNL RCM will form the standard for excellence in the implementation of the LBNL RPP.

  18. Radiological control manual. Revision 1

    International Nuclear Information System (INIS)

    Kloepping, R.

    1996-05-01

    This Lawrence Berkeley National Laboratory Radiological Control Manual (LBNL RCM) has been prepared to provide guidance for site-specific additions, supplements and interpretation of the DOE Radiological Control Manual. The guidance provided in this manual is one methodology to implement the requirements given in Title 10 Code of Federal Regulations Part 835 (10 CFR 835) and the DOE Radiological Control Manual. Information given in this manual is also intended to provide demonstration of compliance to specific requirements in 10 CFR 835. The LBNL RCM (Publication 3113) and LBNL Health and Safety Manual Publication-3000 form the technical basis for the LBNL RPP and will be revised as necessary to ensure that current requirements from Rules and Orders are represented. The LBNL RCM will form the standard for excellence in the implementation of the LBNL RPP

  19. CRISP instrument manual

    International Nuclear Information System (INIS)

    Bucknall, D.G.; Langridge, Sean

    1997-05-01

    This document is a user manual for CRISP, one of the two neutron reflectomers at ISIS. CRISP is highly automated allowing precision reproducible measurements. The manual provides detailed instructions for the setting-up and running of the instrument and advice on data analysis. (UK)

  20. Salinas : theory manual.

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Timothy Francis; Reese, Garth M.; Bhardwaj, Manoj Kumar

    2004-08-01

    This manual describes the theory behind many of the constructs in Salinas. For a more detailed description of how to use Salinas , we refer the reader to Salinas, User's Notes. Many of the constructs in Salinas are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Salinas are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programer-notes manual, the user's notes and of course the material in the open literature.

  1. PCs The Missing Manual

    CERN Document Server

    Karp, David

    2005-01-01

    Your vacuum comes with one. Even your blender comes with one. But your PC--something that costs a whole lot more and is likely to be used daily and for tasks of far greater importance and complexity--doesn't come with a printed manual. Thankfully, that's not a problem any longer: PCs: The Missing Manual explains everything you need to know about PCs, both inside and out, and how to keep them running smoothly and working the way you want them to work. A complete PC manual for both beginners and power users, PCs: The Missing Manual has something for everyone. PC novices will appreciate the una

  2. Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

    International Nuclear Information System (INIS)

    Heeswijk, Miriam M. van; Lambregts, Doenja M.J.; Griethuysen, Joost J.M. van; Oei, Stanley; Rao, Sheng-Xiang; Graaff, Carla A.M. de; Vliegen, Roy F.A.; Beets, Geerard L.; Papanikolaou, Nikos; Beets-Tan, Regina G.H.

    2016-01-01

    Purpose: Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Methods and Materials: Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Results: Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the

  3. Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

    Energy Technology Data Exchange (ETDEWEB)

    Heeswijk, Miriam M. van [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Centre, Maastricht (Netherlands); Lambregts, Doenja M.J., E-mail: d.lambregts@nki.nl [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Radiology, The Netherlands Cancer Institute, Amsterdam (Netherlands); Griethuysen, Joost J.M. van [GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Radiology, The Netherlands Cancer Institute, Amsterdam (Netherlands); Oei, Stanley [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Rao, Sheng-Xiang [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai (China); Graaff, Carla A.M. de [Department of Radiology, Maastricht University Medical Centre, Maastricht (Netherlands); Vliegen, Roy F.A. [Atrium Medical Centre Parkstad/Zuyderland Medical Centre, Heerlen (Netherlands); Beets, Geerard L. [GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Surgery, The Netherlands Cancer Institute, Amsterdam (Netherlands); Papanikolaou, Nikos [Laboratory of Computational Medicine, Institute of Computer Science, FORTH, Heraklion, Crete (Greece); Beets-Tan, Regina G.H. [GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre, Maastricht (Netherlands); Department of Radiology, The Netherlands Cancer Institute, Amsterdam (Netherlands)

    2016-03-15

    Purpose: Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Methods and Materials: Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Results: Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the

  4. HEFF---A user's manual and guide for the HEFF code for thermal-mechanical analysis using the boundary-element method

    International Nuclear Information System (INIS)

    St John, C.M.; Sanjeevan, K.

    1991-12-01

    The HEFF Code combines a simple boundary-element method of stress analysis with the closed form solutions for constant or exponentially decaying heat sources in an infinite elastic body to obtain an approximate method for analysis of underground excavations in a rock mass with heat generation. This manual describes the theoretical basis for the code, the code structure, model preparation, and step taken to assure that the code correctly performs its intended functions. The material contained within the report addresses the Software Quality Assurance Requirements for the Yucca Mountain Site Characterization Project. 13 refs., 26 figs., 14 tabs

  5. Validating New Software for Semiautomated Liver Volumetry--Better than Manual Measurement?

    Science.gov (United States)

    Noschinski, L E; Maiwald, B; Voigt, P; Wiltberger, G; Kahn, T; Stumpp, P

    2015-09-01

    This prospective study compared a manual program for liver volumetry with semiautomated software. The hypothesis was that the semiautomated software would be faster, more accurate and less dependent on the evaluator's experience. Ten patients undergoing hemihepatectomy were included in this IRB approved study after written informed consent. All patients underwent a preoperative abdominal 3-phase CT scan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different types of software were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as the gold standard. The resected part was examined with a CT scan after displacement volumetry. Volumetry of the resected liver scan showed excellent correlation to water displacement volumetry (manual: ρ = 0.997; semiautomated software: ρ = 0.995). The difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33% vs. 57%, p = 0.002). The semiautomated software was almost four times faster for volumetry of the whole liver (manual: 6:59 ± 3:04 min; semiautomated: 1:47 ± 1:11 min). Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user's experience. Both tested types of software allow exact volumetry of resected liver parts. Preoperative prediction can be performed more accurately with the semiautomated software. The semiautomated software is nearly four times faster than the

  6. Dose measurements with a HPGe detector - a technical manual

    Energy Technology Data Exchange (ETDEWEB)

    Lidstroem, K.; Nordenfors, C.; Aagren, G

    2000-06-01

    This paper is a technical manual for estimations of dose based on a gamma spectrum. The method used is based on the Monte Carlo code EGS4. Since dose estimations from spectra are specific for each detector, this work is performed on two mobile HPGe detectors at FOA NBC Defence in Umeaa. This technical manual describes the method used in three steps: Part 1 explains how to construct a model of the detector geometry and the specific material for a new detector. Part 2 describes the underlying work of Monte Carlo simulations of a detector given geometry and material. Part 3 describes dose estimations from a gamma spectrum.

  7. Análisis de compuestos volátiles en cilantro ( L. Análisis de compuestos volátiles en cilantro (Coriandrum sativum L.

    Directory of Open Access Journals (Sweden)

    Tábata Rosales-Reyes

    2012-02-01

    Full Text Available In the present study, volatile compounds were recovered from the fresh leaves and stems ofcilantro (Coriandrum sativum L. by two methods: Liquid-Solid Extraction (LSE and SimultaneousDistillation-Extraction (SDE. The identification and quantification was done byGas Chromatography-Mass Spectrometry (GC-MS. Fourteen compounds were characterizedby LSE and GC-MS; whereas by SDE and GC-MS, they were twenty three compounds.The statistical analysis revealed significant quantitative differences (p ≤ 0,05 between theanalyzed techniques (LSE and SDE. In this work, the Simultaneous Distillation-Extractionshowed the greater identification and total concentration of volatile compounds. Aldehydes,monoterpenes, and alcohols comprised 78% of the volatile found for two methods, the restwere hydrocarbons. (E-2-decenal was the most abundant compound in cilantro in bothextraction techniques. En el presente estudio se recuperaron los compuestos volátiles de las hojas y los tallos frescos de cilantro (Coriandrum sativum L. mediante dos métodos: Extracción Sólido Líquido (LSE y Extracción-Destilación Simultánea (SDE. La identificación y cuantificación fue por Cromatografía de Gases-Espectrometría de Masas (GC-MS. Se caracterizaron catorce compuestos por LSE y GC-MS; mientras que por SDE y GC-MS, fueron veintitrés compuestos. El análisis estadístico reveló significativas diferencias cuantitativas (p ≤ 0,05 entre las técnicas analizadas (LSE y SDE. En este trabajo, la Extracción-Destilación Simultánea arrojó la mayor identificación y concentración total de compuestos volátiles. Los aldehídos, monoterpenos y alcoholes comprendieron el 78% de los volátiles encontrados por los dos métodos, el resto fueron hidrocarburos. En ambas técnicas de extracción el (E-2-decenal fue el compuesto más abundante en el cilantro.

  8. Electronic manual of the nuclear characteristics analysis code-set for FBR

    International Nuclear Information System (INIS)

    Makino, Tohru

    2001-03-01

    Reactor Physics Gr., System Engineering Technology Division, O-arai Engineering Center has consolidated the nuclear design database to improve analytical methods and prediction accuracy for large fast breeder cores such as demonstration or commercial FBRs from the previous research. The up-to-date information about usage of the nuclear characteristics analysis code-set was compiled as a part of the improvement of basic design data base for FBR core. The outlines of the electronic manual are as follows; (1) The electronic manual includes explanations of following codes: JOINT : Code Interface Program. SLAROM, CASUP : Effective Cross Section Calculation Code. CITATION-FBR : Diffusion Analysis Code. PERKY : Perturbative Diffusion Analysis Code. SNPERT, SNPERT-3D : Perturbative Transport Analysis Code. SAGEP, SAGEP-3D : Sensitivity Coefficient Calculation Code. NSHEX : Transport Analysis Code using Nodal Method. ABLE : Cross Section Adjustment Calculation Code. ACCEPT : Predicting Accuracy Evaluation Code. (2) The electronic manual is described using HTML file format and PDF file for easy maintenance, updating and for easy referring through JNC Intranet. User can refer manual pages by usual Web browser software without any special setup. (3) Many of manual pages include link-tags to jump to related pages. String search is available in both HTML and PDF documents. (4) User can download source code, sample input data and shell script files to carry out each analysis from download page of each code (JNC inside only). (5) Usage of the electronic manual and maintenance/updating process are described in this report and it makes possible to enroll new code or new information in the electronic manual. Since the information has been taken into account about modifications and error fixings, added to each code after the last consolidation in 1994, the electronic manual would cover most recent status of the nuclear characteristics analysis code-set. One of other advantages of use

  9. Anestesia volátil e monitorização anestésica.

    OpenAIRE

    Alexandre, Nuno; Costa, Margarida; Mascarenhas, Ramiro

    2009-01-01

    Os autores apresentam um texto de apoio à disciplina de anestesiologia do curso de Medicina Veterinária .Neste texto são abordadas diversas temáticas da anestesia volátil tais como: equipamentos utilizados em anestesia volátil, farmacologia dos anestésicos voláteis. A monitorização dos pacientes é abordada na vertente mecânica ou intrumental e na componente básica.

  10. Index to Nuclear Safety: a technical progress review by chronology, permuted title, and author. Vol. 11(1)--Vol. 18(6)

    Energy Technology Data Exchange (ETDEWEB)

    Cottrell, W.B.; Klein, A.

    1978-04-11

    This index to Nuclear Safety covers articles published in Nuclear Safety, Vol. 11, No. 1 (January-February 1970), through Vol. 18, No. 6 (November-December 1977). It is divided into three sections: a chronological list of articles (including abstracts) followed by a permuted-title (KWIC) index and an author index. Nuclear Safety, a bimonthly technical progress review prepared by the Nuclear Safety Information Center (NSIC), covers all safety aspects of nuclear power reactors and associated facilities. Over 450 technical articles published in Nuclear Safety in the last eight years are listed in this index.

  11. Index to Nuclear Safety: a technical progress review by chronology, permuted title, and author. Vol. 11(1)--Vol. 18(6)

    International Nuclear Information System (INIS)

    Cottrell, W.B.; Klein, A.

    1978-01-01

    This index to Nuclear Safety covers articles published in Nuclear Safety, Vol. 11, No. 1 (January-February 1970), through Vol. 18, No. 6 (November-December 1977). It is divided into three sections: a chronological list of articles (including abstracts) followed by a permuted-title (KWIC) index and an author index. Nuclear Safety, a bimonthly technical progress review prepared by the Nuclear Safety Information Center (NSIC), covers all safety aspects of nuclear power reactors and associated facilities. Over 450 technical articles published in Nuclear Safety in the last eight years are listed in this index

  12. Ethiopian Journal of Health Sciences - Vol 28, No 2 (2018)

    African Journals Online (AJOL)

    Ethiopian Journal of Health Sciences - Vol 28, No 2 (2018). Journal Home > Archives > Vol 28, No 2 (2018). Log in or Register to get access to full text downloads. ... Prevalence of opportunistic intestinal parasites and associated factors among HIV patients while receiving ART at Arba Minch Hospital in southern Ethiopia: a ...

  13. Quantitative Risk Assessment of Patient Manual Handling in Wards of One of the Hospitals of Tehran using MAPO Method, Iran

    Directory of Open Access Journals (Sweden)

    Sajad Ataei

    2017-05-01

    Full Text Available Background and Objectives: Manual handling of disabled patients is one of the important and effective factors in acute low back pain among exposed nurses. The present study was conducted with the objective of quantitative risk assessment of patient manual handling among nurses in wards of one of the hospitals in Tehran using MAPO method. Methods: The present study was conducted as an analytical-cross-sectional study in 26 wards of one of the hospitals in Tehran city. Samples were selected by census method from nurses and paramedics of different wards of hospital. Data collection was performed using demographic information and MAPO checklist. Results: The highest score of MAPO were, respectively, related to wards of DI clinic (score, 14.7, men orthopedic (score, 6.3, and general operating room (score, 57. 53.8% of hospital wards were at the level 2 corrective action, which indicated that the risk of musculoskeletal disorder is 2.4 times higher than level 1 corrective action. Conclusion: Given that the proportion of disabled patient in cooperation and/or partial cooperation, lifting tools, auxiliary, wheelchair, and training have the most role among risk factors for above-mentioned wards, increasing the number of human resources and wheelchair, use of lifting and auxiliary tools and training reduce MAPO score and consequently the risk of musculoskeletal disorders.

  14. Automated and Semiautomated Segmentation of Rectal Tumor Volumes on Diffusion-Weighted MRI: Can It Replace Manual Volumetry?

    Science.gov (United States)

    van Heeswijk, Miriam M; Lambregts, Doenja M J; van Griethuysen, Joost J M; Oei, Stanley; Rao, Sheng-Xiang; de Graaff, Carla A M; Vliegen, Roy F A; Beets, Geerard L; Papanikolaou, Nikos; Beets-Tan, Regina G H

    2016-03-15

    Diffusion-weighted imaging (DWI) tumor volumetry is promising for rectal cancer response assessment, but an important drawback is that manual per-slice tumor delineation can be highly time consuming. This study investigated whether manual DWI-volumetry can be reproduced using a (semi)automated segmentation approach. Seventy-nine patients underwent magnetic resonance imaging (MRI) that included DWI (highest b value [b1000 or b1100]) before and after chemoradiation therapy (CRT). Tumor volumes were assessed on b1000 (or b1100) DWI before and after CRT by means of (1) automated segmentation (by 2 inexperienced readers), (2) semiautomated segmentation (manual adjustment of the volumes obtained by method 1 by 2 radiologists), and (3) manual segmentation (by 2 radiologists); this last assessment served as the reference standard. Intraclass correlation coefficients (ICC) and Dice similarity indices (DSI) were calculated to evaluate agreement between different methods and observers. Measurement times (from a radiologist's perspective) were recorded for each method. Tumor volumes were not significantly different among the 3 methods, either before or after CRT (P=.08 to .92). ICCs compared to manual segmentation were 0.80 to 0.91 and 0.53 to 0.66 before and after CRT, respectively, for the automated segmentation and 0.91 to 0.97 and 0.61 to 0.75, respectively, for the semiautomated method. Interobserver agreement (ICC) pre and post CRT was 0.82 and 0.59 for automated segmentation, 0.91 and 0.73 for semiautomated segmentation, and 0.91 and 0.75 for manual segmentation, respectively. Mean DSI between the automated and semiautomated method were 0.83 and 0.58 pre-CRT and post-CRT, respectively; DSI between the automated and manual segmentation were 0.68 and 0.42 and 0.70 and 0.41 between the semiautomated and manual segmentation, respectively. Median measurement time for the radiologists was 0 seconds (pre- and post-CRT) for the automated method, 41 to 69 seconds (pre-CRT) and

  15. A background to risk analysis. Vol. 3

    International Nuclear Information System (INIS)

    Taylor, J.R.

    1979-01-01

    This 4-volumes report gives a background of ideas, principles, and examples which might be of use in developing practical methods for risk analysis. Some of the risk analysis techniques described are somewhat experimental. The report is written in an introductory style, but where some point needs further justifi- cation or evaluation, this is given in the form of a chapter appenix. In this way, it is hoped that the report can serve two purposes, - as a basis for starting risk analysis work and as a basis for discussing effectiveness of risk analysis procedures. The report should be seen as a preliminary stage, prior to a program of industrial trials of risk analysis methods. Vol. 3 contains chapters on quantification of risk, failure and accident probability, risk analysis and design, and examles of risk analysis for process plant. (BP)

  16. Comparison of manual and semi-automated delineation of regions of interest for radioligand PET imaging analysis

    International Nuclear Information System (INIS)

    Chow, Tiffany W; Verhoeff, Nicolaas PLG; Takeshita, Shinichiro; Honjo, Kie; Pataky, Christina E; St Jacques, Peggy L; Kusano, Maggie L; Caldwell, Curtis B; Ramirez, Joel; Black, Sandra

    2007-01-01

    As imaging centers produce higher resolution research scans, the number of man-hours required to process regional data has become a major concern. Comparison of automated vs. manual methodology has not been reported for functional imaging. We explored validation of using automation to delineate regions of interest on positron emission tomography (PET) scans. The purpose of this study was to ascertain improvements in image processing time and reproducibility of a semi-automated brain region extraction (SABRE) method over manual delineation of regions of interest (ROIs). We compared 2 sets of partial volume corrected serotonin 1a receptor binding potentials (BPs) resulting from manual vs. semi-automated methods. BPs were obtained from subjects meeting consensus criteria for frontotemporal degeneration and from age- and gender-matched healthy controls. Two trained raters provided each set of data to conduct comparisons of inter-rater mean image processing time, rank order of BPs for 9 PET scans, intra- and inter-rater intraclass correlation coefficients (ICC), repeatability coefficients (RC), percentages of the average parameter value (RM%), and effect sizes of either method. SABRE saved approximately 3 hours of processing time per PET subject over manual delineation (p < .001). Quality of the SABRE BP results was preserved relative to the rank order of subjects by manual methods. Intra- and inter-rater ICC were high (>0.8) for both methods. RC and RM% were lower for the manual method across all ROIs, indicating less intra-rater variance across PET subjects' BPs. SABRE demonstrated significant time savings and no significant difference in reproducibility over manual methods, justifying the use of SABRE in serotonin 1a receptor radioligand PET imaging analysis. This implies that semi-automated ROI delineation is a valid methodology for future PET imaging analysis

  17. Eco-Innovation Manual

    DEFF Research Database (Denmark)

    O'Hare, Jamie Alexander; McAloone, Tim C.; Pigosso, Daniela Cristina Antelmi

    Aim of this manual is to introduce a methodology for the implementation of eco‐innovation within small and medium sized companies in developing and emerging economies. The intended audience of this manual is organizations that provide professional services to guide and support manufacturing compa...... companies to improve their sustainability performance....

  18. Dynamics of structures '89. Vol. 1 and 2

    International Nuclear Information System (INIS)

    1989-01-01

    The proceedings, comprising 3 volumes published by the Plzen Centre of the Czechoslovak Society for Science and Technology (Vol. 1 and 2) and by Skoda Works in Plzen (Vol. 3), contain 107 papers, out of which 8 fall within the INIS Subject Scope; these deal with problems related to the earthquake resistance of nuclear power plants. Attention is paid to the evaluation of seismic characteristics of nuclear power plant equipment, to the equipment testing and to calculations of its dynamic characteristics under simulated seismic stress. (Z.M.)

  19. Large hadron collider workshop. Proceedings. Vol. 3

    International Nuclear Information System (INIS)

    Jarlskog, G.; Rein, D.

    1990-01-01

    The aim of the LHC workshop at Aachen was to discuss the 'discovery potential' of a high-luminosity hadron collider (the Large Hadron Collider) and to define the requirements of the detectors. Of central interest was whether a Higgs particle with mass below 1 TeV could be seen using detectors potentially available within a few years from now. Other topics included supersymmetry, heavy quarks, excited gauge bosons, and exotica in proton-proton collisions, as well as physics to be observed in electron-proton and heavy-ion collisions. A large part of the workshop was devoted to the discussion of instrumental and detector concepts, including simulation, signal processing, data acquisition, tracking, calorimetry, lepton identification and radiation hardness. The workshop began with parallel sessions of working groups on physics and instrumentaiton and continued, in the second half, with plenary talks giving overviews of the LHC project and the SSC, RHIC, and HERA programmes, summaries of the working groups, presentations from industry, and conclusions. Vol. 1 of these proceedings contains the papers presented at the plenary sessions, Vol. 2 the individual contributions to the physics sessions, and Vol. 3 those to the instrumentation sessions. (orig.)

  20. Large hadron collider workshop. Proceedings. Vol. 2

    International Nuclear Information System (INIS)

    Jarlskog, G.; Rein, D.

    1990-01-01

    The aim of the LHC workshop at Aachen was to discuss the 'discovery potential' of a high-luminosity hadron collider (the Large Hadron Collider) and to define the requirements of the detectors. Of central interest was whether a Higgs particle with mass below 1 TeV could be seen using detectors potentially available within a few years from now. Other topics included supersymmetry, heavy quarks, excited gauge bosons, and exotica in proton-proton collisions, as well as physics to be observed in electron-proton and heavy-ion collisions. A large part of the workshop was devoted to the discussion of instrumental and detector concepts, including simulation, signal processing, data acquisition, tracking, calorimetry, lepton identification and radiation hardness. The workshop began with parallel sessions of working groups on physics and instrumentation and continued, in the second half, with plenary talks giving overviews of the LHC project and the SSC, RHIC, and HERA programmes, summaries of the working groups, presentations from industry, and conclusions. Vol.1 of these proceedings contains the papers presented at the plenary sessions, Vol.2 the individual contributions to the physics sessions, and Vol.3 those to the instrumentation sessions. (orig.)

  1. Large hadron collider workshop. Proceedings. Vol. 1

    International Nuclear Information System (INIS)

    Jarlskog, G.; Rein, D.

    1990-01-01

    The aim of the LCH workshop at Aachen was to discuss the 'discovery potential' of a high-luminosity hadron collider (the Large Hadron Collider) and to define the requirements of the detectors. Of central interest was whether a Higgs particle with mass below 1 TeV could be seen using detectors potentially available within a few years from now. Other topics included supersymmetry, heavy quarks, excited gauge bosons, and exotica in proton-proton collisions, as well as physics to be observed in electron-proton and heavy-ion collisions. A large part of the workshop was devoted to the discussion of instrumental and detector concepts, including simulation, signal processing, data acquisition, tracking, calorimetry, lepton identification and radiation hardness. The workshop began with parallel sessions of working groups on physics and instrumentation and continued, in the second half, with plenary talks giving overviews of the LHC project and the SSC, RHIC, and HERA programmes, summaries of the working groups, presentations from industry, and conclusions. Vol. 1 of these proceedings contains the papers presented at the plenary sessions, Vol. 2 the individual contributions to the physics sessions, and Vol. 3 those to the instrumentation sessions. (orig.)

  2. UQTk version 2.0 user manual

    Energy Technology Data Exchange (ETDEWEB)

    Debusschere, Bert J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sargsyan, Khachik [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Safta, Cosmin [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2013-10-01

    The UQ Toolkit (UQTk) is a collection of libraries and tools for the quantification of uncertainty in numerical model predictions. Version 2.0 ffers intrusive and non-intrusive methods for propagating input uncertainties through computational models, tools for sensitivity analysis, methods for sparse surrogate construction, and Bayesian inference tools for inferring parameters from experimental data. This manual discusses the download and installation process for UQTk, provides pointers to the UQ methods used in the toolkit, and describes some of the examples provided with the toolkit.

  3. Errata Resonance, Vol.20, No.12, 2015. Rajaram Nityananda, Sun ...

    Indian Academy of Sciences (India)

    IAS Admin

    Resonance, Vol.20, No.12, 2015. Rajaram Nityananda, Sun, Sky and Clouds: Where Light and Matter Meet. Page 1121: The correct Figure 5 is reproduced below: Resonance, Vol.20, No.11, 2015. Anil Kumar, Felix Bloch (1905–1983). Page 956: Para 1, Line 5, 'also from Zürich' should be read as 'from nearby Bern'.

  4. Information manager-2011-Vol 11

    African Journals Online (AJOL)

    Library _info_Sc_ 1

    The Information Manager Vol. ... extent while carrying out their duties on a daily basis. ... It concluded by admonishing librarians to brace up and keep pace ... Proper training should be given to .... used to information and communication technologies .... proficiency Skills .... analysis of the workplace and implementation of.

  5. Are the new automated methods for bone age estimation advantageous over the manual approaches?

    Science.gov (United States)

    De Sanctis, Vincenzo; Soliman, Ashraf T; Di Maio, Salvatore; Bedair, Said

    2014-12-01

    Bone Age Assessment (BAA) is performed worldwide for the evaluation of endocrine, genetic and chronic diseases, to monitor response to medical therapy and to determine the growth potential of children and adolescents. It is also used for consultation in planning orthopedic procedures, for determination of chronological age for adopted children, youth sports participation and in forensic settings. The main clinical methods for skeletal bone age estimation are the Greulich and Pyle (GP) and the Tanner and Whitehouse (TW) methods. Seventy six per cent (76%) of radiologists or pediatricians usually use the method of GP, 20% that of TW and 4% other methods. The advantages of using the TW method, as opposed to the GP method, are that it overcomes the subjectivity problem and results are more reproducible. However, it is complex and time consuming; for this reason its usage is just about 20% on a world-wide scale. Moreover, there are some evidences that bone age assignments by different physicians can differ significantly. Computerized and Quantitative Ultrasound Technologies (QUS) for assessing skeletal maturity have been developed with the aim of reducing many of the inconsistencies associated with radiographic investigations. In spite of the fact that the volume of automated methods for BAA has increased, the majotity of them are still in an early phase of development. QUS is comparable to the GP based method, but there is not enough established data yet for the healthy population. The Authors wish to stimulate the attention on the accuracy, reliability and consistency of BAA and to initiate a debate on manual versus automated approaches to enhance our assessment for skeletal matutation in children and adolescents.

  6. Biosafety Manual

    Energy Technology Data Exchange (ETDEWEB)

    King, Bruce W.

    2010-05-18

    Work with or potential exposure to biological materials in the course of performing research or other work activities at Lawrence Berkeley National Laboratory (LBNL) must be conducted in a safe, ethical, environmentally sound, and compliant manner. Work must be conducted in accordance with established biosafety standards, the principles and functions of Integrated Safety Management (ISM), this Biosafety Manual, Chapter 26 (Biosafety) of the Health and Safety Manual (PUB-3000), and applicable standards and LBNL policies. The purpose of the Biosafety Program is to protect workers, the public, agriculture, and the environment from exposure to biological agents or materials that may cause disease or other detrimental effects in humans, animals, or plants. This manual provides workers; line management; Environment, Health, and Safety (EH&S) Division staff; Institutional Biosafety Committee (IBC) members; and others with a comprehensive overview of biosafety principles, requirements from biosafety standards, and measures needed to control biological risks in work activities and facilities at LBNL.

  7. Expressive Vocabulary Acquisition in Children with Intellectual Disability: Speech or Manual Signs?

    Science.gov (United States)

    Vandereet, Joke; Maes, Bea; Lembrechts, Dirk; Zink, Inge

    2011-01-01

    Background: The aim of this study was to examine the degree to which children with intellectual disability (ID) depend on manual signs during their expressive vocabulary acquisition, in relation to child and social-environmental characteristics. Method: Expressive vocabulary acquisition in speech and manual signs was monitored over a 2-year period…

  8. Manual for implementing residual radioactivity guidelines

    International Nuclear Information System (INIS)

    Gilbert, T.L.; Eckerman, K.F.; Hansen, W.R.; Healy, J.W.; Kennedy, W.E.; Napier, B.A.; Solday, J.K.

    1986-01-01

    The US Department of Energy (DOE) has recently issued guidelines for residual radioactivity at Formerly Utilized Sites Remedial Action Program (FUSRAP) and remote Surplus Facilities Management Program (SFMP) sites. A manual for implementing these guidelines has been prepared jointly by four DOE laboratories (ANL, LANL, ORNL, and PNL) and is being issued as a supplement to the guidelines. The manual presents procedures and tables for deriving site-specific guidelines for levels of residual radionuclide concentrations in soil that must not be exceeded if a site is to be released for unrestricted use. Guidance for implementing DOE ALARA policy for remedial actions is also included. The concentration factor method is used in the pathway analysis for deriving soil guidelines. The analysis has been structured in a manner that explicitly identifies all of the factors involved. Tables are provided for dose-conversion factors and pathway factors from which environmental transport factors for each radionuclide and pathway may be calculated. The scenarios used for deriving the environmental transport factors and dose conversion factors, and the manner in which the information provided in the manual is used to derive site-specific soil guidelines will be presented

  9. Risk assessment related to manual handling on choosen work possition in foundry Alstom Power Sp. z o. o.

    Directory of Open Access Journals (Sweden)

    G. Kowal

    2010-04-01

    Full Text Available Manual handling remains one of the different types of transport inside working place, although technological progress and modernorganization of work. Manual transport as a transport inside working place is related to foundry industry. According to polish lawregulations employer has to give consideration to manual handling in professional risk assessment and introduce actions for manualhandling reduction. In Foundry Elblag case there is found that in many processes manual handling are made by workers. For example wecan choose melting processes (additives manual feeding, mixing and pulling metallurgical slag, etc. or fettling processes like grinding.Objective of that analysis was to define level of risk related to manual handling in work stand chosen and define activities impacted onrisk assessment result with biggest range. For risk reduction, technical and organizational solutions were shown (better ergonomically work stand, method of work and worker’s awareness about good practices. In this study methods related to manual handling risk assessment were described, focus on KIM method used in Foundry Elblag. Key Item Method allow to estimate the risk by simple calculation based on key indicators (time rating points, rating points of mass, posture or work condition. Points were chosen based on timekeeping, information from workers and foreman.

  10. The Warfighter’s Stress Response: Telemetric and Noninvasive Assessment

    Science.gov (United States)

    2002-09-01

    cortex lesions on cardiovascular conditioned emotional responses in the rat. Brain Research. Vol 643(1-2), Apr 1994, 181- 193. 37. Stark, Rudolf; Hamm...J., Turner, B., & Simon, M.A. (1999). Research methods in health psychology. In M.A. Simon (Ed.), Manual de psicologia de la salud: Fundamentos

  11. ACT Plan: Technical Manual. 2013/2014

    Science.gov (United States)

    ACT, Inc., 2013

    2013-01-01

    This manual contains information about the American College Test (ACT) Plan® program. The principal focus of this manual is to document the Plan program's technical adequacy in light of its intended purposes. This manual supersedes the 2011 edition. The content of this manual responds to requirements of the testing industry as established in the…

  12. Index to Nuclear Safety. A technical progress review by chronology, permuted title, and author. Vol. 11, No. 1--Vol. 17, No. 6

    International Nuclear Information System (INIS)

    Cottrell, W.B.; Klein, A.

    1977-01-01

    This index to Nuclear Safety covers articles in Nuclear Safety Vol. 11, No. 1 (Jan.-Feb. 1970), through Vol. 17, No. 6 (Nov.-Dec. 1976). The index includes a chronological list of articles (including abstract) followed by KWIC and Author Indexes. Nuclear Safety, a bimonthly technical progress review prepared by the Nuclear Safety Information Center, covers all safety aspects of nuclear power reactors and associated facilities. The index lists over 350 technical articles in the last six years of publication

  13. Index to Nuclear Safety. A technical progress review by chronology, permuted title, and author. Vol. 11, No. 1--Vol. 17, No. 6

    Energy Technology Data Exchange (ETDEWEB)

    Cottrell, W.B.; Klein, A.

    1977-02-23

    This index to Nuclear Safety covers articles in Nuclear Safety Vol. 11, No. 1 (Jan.-Feb. 1970), through Vol. 17, No. 6 (Nov.-Dec. 1976). The index includes a chronological list of articles (including abstract) followed by KWIC and Author Indexes. Nuclear Safety, a bimonthly technical progress review prepared by the Nuclear Safety Information Center, covers all safety aspects of nuclear power reactors and associated facilities. The index lists over 350 technical articles in the last six years of publication.

  14. US Fish and Wildlife Service lands biomonitoring operations manual

    Energy Technology Data Exchange (ETDEWEB)

    Rope, R.C.; Breckenridge, R.P.

    1993-08-01

    This is Volume 1 of an operations manual designed to facilitate the development of biomonitoring strategies for U.S. Fish and Wildlife Service Lands. It is one component of the U.S. Fish and Wildlife Service Lands Biomonitoring Operations Manual. The Volume contains the Introduction to the Manual, background information on monitoring, and procedures for developing a biomonitoring strategy for Service lands. The purpose of the Biomonitoring Operations Manual is to provide an approach to develop and implement biomonitoring activities to assess the status and trends of U.S. Fish and Wildlife Service trust resources. It also provides field sampline methods and documentation protocols for contaminant monitoring activities. The strategy described in the Manual has been designed as a stand alone process to characterize the presence of contaminants on lands managed by the Service. This process can be sued to develop a monitoring program for any tract of real estate with potential threats from on- or off-site contaminants. Because the process was designed to address concerns for Service lands that span the United States from Alaska to the Tropical Islands, it has a generic format that can be used in al types of ecosystems, however, significant site specific informtion is required to complete the Workbook and make the process work successfully.

  15. Operation and Maintenance Manual for the Central Facilities Area Sewage Treatment Plant

    Energy Technology Data Exchange (ETDEWEB)

    Norm Stanley

    2011-02-01

    This Operation and Maintenance Manual lists operator and management responsibilities, permit standards, general operating procedures, maintenance requirements and monitoring methods for the Sewage Treatment Plant at the Central Facilities Area at the Idaho National Laboratory. The manual is required by the Municipal Wastewater Reuse Permit (LA-000141-03) the sewage treatment plant.

  16. Standardisation of costs: the Dutch Manual for Costing in economic evaluations.

    Science.gov (United States)

    Oostenbrink, Jan B; Koopmanschap, Marc A; Rutten, Frans F H

    2002-01-01

    The lack of a uniform costing methodology is often considered a weakness of economic evaluations that hinders the interpretation and comparison of studies. Standardisation is therefore an important topic within the methodology of economic evaluations and in national guidelines that formulate the formal requirements for studies to be considered when deciding on the reimbursement of new medical therapies. Recently, the Dutch Manual for Costing: Methods and Standard Costs for Economic Evaluations in Health Care (further referred to as "the manual") has been published, in addition to the Dutch guidelines for pharmacoeconomic research. The objectives of this article are to describe the main content of the manual and to discuss some key issues of the manual in relation to the standardisation of costs. The manual introduces a six-step procedure for costing. These steps concern: the scope of the study;the choice of cost categories;the identification of units;the measurement of resource use;the monetary valuation of units; andthe calculation of unit costs. Each step consists of a number of choices and these together define the approach taken. In addition to a description of the costing process, five key issues regarding the standardisation of costs are distinguished. These are the use of basic principles, methods for measurement and valuation, standard costs (average prices of healthcare services), standard values (values that can be used within unit cost calculations), and the reporting of outcomes. The use of the basic principles, standard values and minimal requirements for reporting outcomes, as defined in the manual, are obligatory in studies that support submissions to acquire reimbursement for new pharmaceuticals. Whether to use standard costs, and the choice of a particular method to measure or value costs, is left mainly to the investigator, depending on the specific study setting. In conclusion, several instruments are available to increase standardisation in

  17. NJB VOL.34 Original Lower.cdr

    African Journals Online (AJOL)

    important sources of renewable biological ... The plantain (Musa paradisiaca) and banana chemicals (Nowak et ... fermentable sugars available for bio-ethanol ..... peels. Afr. J. Biochem. Res. 9(9): 104 - 109. 70. Osho et al./ Nig. J. Biotech. Vol.

  18. Thermic diode performance characteristics and design manual

    Science.gov (United States)

    Bernard, D. E.; Buckley, S.

    1979-01-01

    Thermic diode solar panels are a passive method of space and hot water heating using the thermosyphon principle. Simplified methods of sizing and performing economic analyses of solar heating systems had until now been limited to passive systems. A mathematical model of the thermic diode including its high level of stratification has been constructed allowing its performance characteristics to be studied. Further analysis resulted in a thermic diode design manual based on the f-chart method.

  19. GRACE manual

    International Nuclear Information System (INIS)

    Ishikawa, T.; Kawabata, S.; Shimizu, Y.; Kaneko, T.; Kato, K.; Tanaka, H.

    1993-02-01

    This manual is composed of three kinds of objects, theoretical background for calculating the cross section of elementary process, usage and technical details of the GRACE system. Throughout this manual we take the tree level process e + e - → W + W - γ as an example, including the e ± -scalar boson interactions. The real FORTRAN source code for this process is attached in the relevant sections as well as the results of calculation, which might be a great help for understanding the practical use of the system. (J.P.N.)

  20. Partners Plus: Families and Caregivers in Partnerships. A Family-Centered Guide to Respite Care. Trainer's Workshop Manual [and] Community Planning Manual [and] A Family Manual [and] Caregiver Manual.

    Science.gov (United States)

    Ownby, Lisa L.; Hooke, Amanda C.; Moore, Dee Wylie; Garland, Corinne W.; Frank, Adrienne

    Four manuals on implementing the Partners Respite Model, which provides respite care for children with disabilities or chronic illnesses, comprise this document. The Community Planning Manual offers a step-by-step guide to replication of the Partners Respite Model and is divided into sections on developing the Partners program, implementing the…

  1. Merchandising. Michigan School Food Service Training Manual.

    Science.gov (United States)

    Michigan State Univ., East Lansing. Cooperative Extension Service.

    The Merchandising Food Service Training Manual contains 12 lessons and 2 appendixes. Class activities and handouts are interspersed among techniques for selling and merchandising meals, information about life value roles and how food participants may improve public images, material about customers' backgrounds and attitudes, methods of competitors…

  2. Technical reference manual for TIME4. Version 1.0, Volume 1

    International Nuclear Information System (INIS)

    Wilmot, R.D.; Ringrose, P.S.; Larkin, J.P.A.; Kleissen, F.A.T.

    1991-07-01

    This document is the Technical Reference Manual for the TIME4 model. TIME4 is the environmental change model developed for use in the probabilistic risk analysis of deep disposal of radioactive waste. The Technical Reference Manual describes the theoretical background to the model. The modelling method is described, followed by a review of related work and a detailed description for each sub-model. (author)

  3. The ISIS Open GENIE user manual

    International Nuclear Information System (INIS)

    Akeroyd, F.A.; Ashworth, R.L.; Campbell, S.I.; Johnston, S.D.; Martin, J.M.; Moreton-Smith, C.M.; Sivia, D.S.

    2000-01-01

    This manual should enable you to become familiar with Open GENIE quickly and easily. It therefore complements the Open GENIE Reference Manual which should be used to understand the full meaning of Open GENIE commands. The reference manual is accessible on the ISIS web server at: http://www.isis.rl.ac.uk/GENIEReferenceManual/ and the user manual is planned to be accessible by January '98 at http://www.isis.rl.ac.ukIGENIEUserManual/. The Open GENIE User Manual is separated into two parts: Part A. The User Manual. An introduction to the use of Open GENIE. Part B. The Installation Guide. General information on how to install and run Open GENIE. Assuming that you are new to Open GENIE and have just downloaded a copy you will need to consult the Installation Guide to get Open GENIE installed on your machine. After this we recommend you experiment with some of the example files to get an idea of the capabilities of Open GENIE. For further information, comments, additions of routines that you feel should be included, please contact us at genie at isise.rl.ac.uk

  4. The operation and maintenance manual

    International Nuclear Information System (INIS)

    Stoll, A.; Krotil, H.; Klein, W.

    1976-01-01

    The operating manual is one of many technical documents which the nuclear power plant operator needs for ensuring safe operation. For the operating staff, however, there is only one document, namely the operating manual. The operating manual is an essential element in bringing man and machine in harmony. This is necessary for safe and, as far as possible, uninterrupted operation of the power plant. The operating manual is the only document containing binding instructions for plant operation. All the tasks of plant operation which are carried out by plant staff are described in the operating manual in a form which is as clear and comprehensible as possible. A considerable number of these tasks can only be carried out by man, namely: 1) tasks concerning operational organization, 2) all non-automated areas of plant operation. (orig./TK) [de

  5. Manual, mechanical, and cultural control methds and tools

    Science.gov (United States)

    Steven Manning; James. Miller

    2011-01-01

    There are many land management scenarios where chemicals are not the ideal choice for controlling invasive plants. More often than not, the best approach is the use of integrated pest management involving a variety of control methods. Maximizing the value of mechanical, manual, and cultural control methods with the added benefit of selective herbicides can offer the...

  6. Fire Protection Program Manual

    Energy Technology Data Exchange (ETDEWEB)

    Sharry, J A

    2012-05-18

    This manual documents the Lawrence Livermore National Laboratory (LLNL) Fire Protection Program. Department of Energy (DOE) Orders 420.1B, Facility Safety, requires LLNL to have a comprehensive and effective fire protection program that protects LLNL personnel and property, the public and the environment. The manual provides LLNL and its facilities with general information and guidance for meeting DOE 420.1B requirements. The recommended readers for this manual are: fire protection officers, fire protection engineers, fire fighters, facility managers, directorage assurance managers, facility coordinators, and ES and H team members.

  7. Central African Journal of Medicine - Vol 60, No 9-12 (2016)

    African Journals Online (AJOL)

    Central African Journal of Medicine - Vol 60, No 9-12 (2016). Journal Home > Archives > Vol 60, No 9-12 (2016). Supplementary Issue. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue ...

  8. Comparison of Manual and Automatic Irrigation of Pot Experiments

    DEFF Research Database (Denmark)

    Haahr, Vagner

    1975-01-01

    An air-lift principle for transport of water was adapted for automatic irrigation of experimental pots originally constructed for manual irrigation by the weighing method. The two irrigation techniques were compared in an experiment with increasing amounts of nitrogen fertilizer to spring barley....... Productions of grain and straw and chemical composition were almost the same after the two irrigation methods, and it was concluded that the laborious manual watering could be replaced by automatic irrigation. Comparison of the yield from individual plants in the pots showed a large difference between centre...... plants and border plants independent of irrigation principle. The increase in yield per pot with increasing N fertilization was at the highest N level caused only by an increase in yield of the border plants....

  9. Outline of manual on measurement and assessment of doses from external radiation

    Energy Technology Data Exchange (ETDEWEB)

    Yoshizawa, Michio [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Tsujimura, Norio

    2001-03-01

    The external exposure part in the manual for measurement and assessment of doses from external radiation is described since the part is changed in accordance with the revision of the Law Concerning Prevention from Radiation Hazard due to Radioisotopes, Etc. The manual contains general remarks, control of external exposure and its methods, person monitoring, site monitoring, correction of instruments and storage of records. The 2nd and 3rd chapters are described in details, because which are considerably changed together with appendices concerning the operational quantity for measuring external dose, conversion coefficients, and correlations of 3 mm, 1 cm and 70 {mu}m dose equivalents. Making manuals unique to the individual offices, etc. is recommended in compliance with the above manual.(K.H.)

  10. Analysis of manual material handling activity to increase work productivity (Case study: manufacturing company

    Directory of Open Access Journals (Sweden)

    Suryoputro Muhammad Ragil

    2018-01-01

    Full Text Available Manual material handling is one of work activities that have an effect on the physical aspect of workers in manufacturing industry, it is necessary to do the analysis of the risks from such activities. Analysis was performed on worker when performing manual lifting activity and when using two tools (Automatic Handlift and Manual Handlift. In addition to analyse in ergonomics aspect, time study analysis and productivity measurement were carried out to determine the effects of the equipment. Nordic Body Map (NBM questionnaire on worker using Automatic Handlift showed declining level of musculoskeletal disorders by 22%. REBA method obtained score of 10 and was declined to 4 after using these tool. The results of MPL method showed declining of Fc value from 4756.37 N to 1346.56 N. The results of RWL method showed declining of LI value (Lifting Index origin and destination from 1.84 and 1.18 to 1.12 and 0.89 respectively. As for worker using Manual Handlift, NBM questionnaire result shows declining level of musculoskeletal disorders by 57%. REBA method obtained scores of 8 and was reduced to 5. For MPL methode result, the Fc value is 4906.99 N and reduced to 2047.88 N. RWL method results showed declining of LI value (Lifting Index origin and destination from 1.02 and 0.67 to 0.74 and 0.58. The results of time study analysis showed declining of Standard Time when use the two tools and make the increasing productivity of 9% by worker using Automatic Hadlift and 4% by worker using Manual Handlift.

  11. A Manual for Basic Techniques of Data Analysis and Distribution

    OpenAIRE

    Alvi, Mohsin

    2014-01-01

    A manual is designed to support and help the basic concepts of statistics and its implications in econometric, beside this, interpretation of further statistical techniques have been shown as well by illustrations and graphical methods. It is comprised on several instances of test, obtained from statistical software like SPSS, E-views, Stata and R-language with the understanding of their research models and essentials for the running the test. A basic of manual is included on two elements, fi...

  12. ARS-Media for excel instruction manual

    Science.gov (United States)

    ARS-Media for Excel Instruction Manual is the instruction manual that explains how to use the Excel spreadsheet ARS-Media for Excel application. ARS-Media for Excel Instruction Manual is provided as a pdf file....

  13. Development of a manualized protocol of massage therapy for clinical trials in osteoarthritis

    Directory of Open Access Journals (Sweden)

    Ali Ather

    2012-10-01

    Full Text Available Abstract Background Clinical trial design of manual therapies may be especially challenging as techniques are often individualized and practitioner-dependent. This paper describes our methods in creating a standardized Swedish massage protocol tailored to subjects with osteoarthritis of the knee while respectful of the individualized nature of massage therapy, as well as implementation of this protocol in two randomized clinical trials. Methods The manualization process involved a collaborative process between methodologic and clinical experts, with the explicit goals of creating a reproducible semi-structured protocol for massage therapy, while allowing some latitude for therapists’ clinical judgment and maintaining consistency with a prior pilot study. Results The manualized protocol addressed identical specified body regions with distinct 30- and 60-min protocols, using standard Swedish strokes. Each protocol specifies the time allocated to each body region. The manualized 30- and 60-min protocols were implemented in a dual-site 24-week randomized dose-finding trial in patients with osteoarthritis of the knee, and is currently being implemented in a three-site 52-week efficacy trial of manualized Swedish massage therapy. In the dose-finding study, therapists adhered to the protocols and significant treatment effects were demonstrated. Conclusions The massage protocol was manualized, using standard techniques, and made flexible for individual practitioner and subject needs. The protocol has been applied in two randomized clinical trials. This manualized Swedish massage protocol has real-world utility and can be readily utilized both in the research and clinical settings. Trial registration Clinicaltrials.gov NCT00970008 (18 August 2009

  14. The design process of a reading comprehension manual

    Directory of Open Access Journals (Sweden)

    Sergio Alonso Lopera Medina

    2015-05-01

    Full Text Available Material design is an important part in the teaching practices. This article describes the process of material design of a foreign language (FL reading manual for undergraduate students at Universidad de Antioquia (Medellín – Colombia. A case study was used as a research method. Four in-service English teachers based their inquiry following the reflective approach of professional development. They also took into account the guidelines to design teaching materials proposed by Howard and Major (2004.  Some of the results of their inquiry for the design of the manual involve contextualization, personalization, and students’ needs. A sample of a reading strategy is given in order to illustrate how teachers worked and designed the manual as a product of their inquiry. Conclusions suggest that this professional development practice helped teachers become more aware of their own teaching realities and also helped them to understand their beliefs and practice in teaching reading as a foreign language.

  15. Right Of Way Pest Control. Manual 88.

    Science.gov (United States)

    Missouri Univ., Columbia. Agricultural Experiment Station.

    This training manual provides information needed to meet the minimum EPA standards for certification as a commercial applicator of pesticides in the right-of-way pest control category. The text discusses types of vegetation, the nature of herbicides, application methods, use for specific situations, and safety precautions. (CS)

  16. Savannah River Plant waste tank inspection manual

    International Nuclear Information System (INIS)

    McNatt, F.G.

    1979-01-01

    This manual is to aid in making visual and photographic inspections and steel thickness measurements of Building 241-F and -H underground waste storage tanks. It describes the inspection program, the storage tanks, the equipment and techniques used and the results of their application, and the inspection recordkeeping methods

  17. RADTRAN 6 Technical Manual

    Energy Technology Data Exchange (ETDEWEB)

    Weiner, Ruth F. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Neuhauser, Karen Sieglinde [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Heames, Terence John [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); O' Donnell, Brandon M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Dennis, Matthew L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2014-01-01

    This Technical Manual contains descriptions of the calculation models and mathematical and numerical methods used in the RADTRAN 6 computer code for transportation risk and consequence assessment. The RADTRAN 6 code combines user-supplied input data with values from an internal library of physical and radiological data to calculate the expected radiological consequences and risks associated with the transportation of radioactive material. Radiological consequences and risks are estimated with numerical models of exposure pathways, receptor populations, package behavior in accidents, and accident severity and probability.

  18. RADTRAN 6 technical manual.

    Energy Technology Data Exchange (ETDEWEB)

    Weiner, Ruth F.; Neuhauser, Karen Sieglinde; Heames, Terence John; O' Donnell, Brandon M.; Dennis, Matthew L.

    2014-01-01

    This Technical Manual contains descriptions of the calculation models and mathematical and numerical methods used in the RADTRAN 6 computer code for transportation risk and consequence assessment. The RADTRAN 6 code combines user-supplied input data with values from an internal library of physical and radiological data to calculate the expected radiological consequences and risks associated with the transportation of radioactive material. Radiological consequences and risks are estimated with numerical models of exposure pathways, receptor populations, package behavior in accidents, and accident severity and probability.

  19. Salinas : theory manual.

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, Timothy Francis; Reese, Garth M.; Bhardwaj, Manoj Kumar

    2011-11-01

    Salinas provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Salinas. For a more detailed description of how to use Salinas, we refer the reader to Salinas, User's Notes. Many of the constructs in Salinas are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Salinas are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer notes manual, the user's notes and of course the material in the open literature.

  20. Clinics in Mother and Child Health - Vol 5, No 1 (2008)

    African Journals Online (AJOL)

    Clinics in Mother and Child Health - Vol 5, No 1 (2008). Journal Home > Archives > Vol 5, No 1 (2008). Special Edition - Congress Abstracts. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register · Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue ...

  1. Proceedings of the Seventh Conference of Nuclear Sciences and Applications. Vol.1,2,3

    International Nuclear Information System (INIS)

    Aly, H.F.

    2000-01-01

    The publication has been set up as a textbook for nuclear sciences and applications vol.1: (1) radiochemistry; (2) radiation chemistry; (3) isotope production; (4) waste management; vol.2: (1) nuclear and reactor; (2) physics; (3) plasma physics; (4) instrumentation and devices; (5) trace and ultra trace analysis; (6) environmental; vol.3: (1) radiation protection; (2) radiation health hazards; (3) nuclear safety; (4) biology; (5) agriculture

  2. Proceedings of the Seventh Conference of Nuclear Sciences and Applications. Vol.1,2,3

    Energy Technology Data Exchange (ETDEWEB)

    Aly, H F [ed.

    2000-07-01

    The publication has been set up as a textbook for nuclear sciences and applications vol.1: (1) radiochemistry; (2) radiation chemistry; (3) isotope production; (4) waste management; vol.2: (1) nuclear and reactor; (2) physics; (3) plasma physics; (4) instrumentation and devices; (5) trace and ultra trace analysis; (6) environmental; vol.3: (1) radiation protection; (2) radiation health hazards; (3) nuclear safety; (4) biology; (5) agriculture.

  3. Proceedings of the second international conference on environmental impact assessment of all economical activities. Vol. 1

    International Nuclear Information System (INIS)

    1993-01-01

    Proceedings of the conference consist of 3 volumes: Vol. 1 - 'Environmental Impact Assessment of all Economical Activities including Industry'; Vol. 2 - 'Air Pollution Control and Prevention'; Vol. 3 - Waste Management and Environmental Problems in Construction Industry'. Out of 32 papers contained in Vol. 1, 2 were inputted to INIS. They deal with models of radionuclide transport in food chains and the use of aerial monitoring in the study of environmental contamination. (Z.S.)

  4. Z Physics at LEP 1. Vol. 3

    International Nuclear Information System (INIS)

    Altarelli, G.; Kleiss, R.; Verzegnassi, C.

    1989-01-01

    The contents of this final report from the Workshop on Z Physics at LEP can be divided into two parts. The first part, comprising Vols. 1 and 2, is a relatively concise but fairly complete handbook on the physics of e + e - annihilation near the Z peak (with normal LEP luminosity and unpolarized beams, appropriate for the first phase of LEP operation). The second part (Vol. 3) is devoted to a review of the existing Monte Carlo event generators for LEP physics. A special effort has been made to co-ordinate the different parts of this report, with the aim of achieving a systematic and balanced review of the subject, rather than having simply a collection of separate contributions. (orig.)

  5. Z physics at LEP 1. Vol. 1

    International Nuclear Information System (INIS)

    Altarelli, G.; Kleiss, R.; Verzegnassi, C.

    1989-01-01

    The contents of this final report from the Workshop on Z Physics at LEP can be divided into two parts. The first part, comprising Vols. 1 and 2, is a relatively concise but fairly complete handbook on the physics of e + e - annihilation near the Z peak (with normal LEP luminosity and unpolarized beams, appropriate for the first phase of LEP operation). The second part (Vol. 3) is devoted to a review of the existing Monte Carlo event generators for LEP physics. A special effort has been made to co-ordinate the different parts of this report, with the aim of achieving a systematic and balanced review of the subject, rather than having simply a collection of separate contributions. (orig.)

  6. TJ-II Library Manual (Version 2)

    International Nuclear Information System (INIS)

    Tribaldos, V.; Milligen, B. Ph. van; Lopez-Fraguas, A.

    2001-01-01

    This is a manual of use of the TJ2 Numerical Library that has been developed for making numerical computations of different TJ-II configurations. This manual is a new version of the earlier manual CIEMAT report 806. (Author)

  7. DIAGNOSTIC CARDIAC CATHETERIZATION USING THE MEDRAD AVANTA FLUID MANAGEMENT SYSTEM AS COMPARED TO THE TRADITIONAL MANUAL INJECTION METHOD

    Energy Technology Data Exchange (ETDEWEB)

    Winniford, Michael D

    2013-02-08

    Nearly 4 million patient procedures performed annually in US cardiac catheterization laboratories utilize contrast media to achieve vessel opacification. The amount of contrast media used is variable and depends on the complexity of the procedure, the method of contrast delivery as well as the skill-level of the operator. Since the total amount of contrast used for each procedure can have both patient safety and economic implications, it is essential for cardiologists to have the ability to control contrast delivery such that optimal angiographic image quality is achieved using the least amount of contrast. Although the complication rate associated with cardiac catheterization remains low, the most common serious complication, contrast-induced nephropathy (CIN), is associated with poor prognosis and a high mortality rate. Numerous interventional strategies for preventing and reducing the severity of CIN have demonstrated varying degrees of clinical benefit, but none has been shown to reliably prevent this serious complication. To date, the most effective approach for reducing the risk of CIN is to properly hydrate the patient and to minimize the amount of contrast media administered. Automated injection systems are intended for use in virtually all cardiac catheterization procedures and have numerous features which can provide potential advantages over traditional methods. With automated injection technology the operator is able to control and precisely monitor contrast delivery. Additionally, the MEDRAD Avanta Fluid Management Injection System utilizes a sterile contrast reservoir which eliminates the need to discard unused contrast in individual opened containers following each procedure. Considering that an average of 50% of opened contrast media is wasted using manual injection methods, this savings can provide a substantial economic benefit. Automated systems also facilitate the use of smaller (5 French) catheter sizes. Precise flow control and the use of

  8. GERTS GQ User's Manual.

    Science.gov (United States)

    Akiba, Y.; And Others

    This user's manual for the simulation program Graphical Evaluation and Review Technique (GERT) GQ contains sections on nodes, branches, program input description and format, and program output, as well as examples. Also included is a programmer's manual which contains information on scheduling, subroutine descriptions, COMMON Variables, and…

  9. Nuclear electronics laboratory manual

    International Nuclear Information System (INIS)

    1984-05-01

    The Nuclear Electronics Laboratory Manual is a joint product of several electronics experts who have been associated with IAEA activity in this field for many years. The manual does not include experiments of a basic nature, such as characteristics of different active electronics components. It starts by introducing small electronics blocks, employing one or more active components. The most demanding exercises instruct a student in the design and construction of complete circuits, as used in commercial nuclear instruments. It is expected that a student who completes all the experiments in the manual should be in a position to design nuclear electronics units and also to understand the functions of advanced commercial instruments which need to be repaired or maintained. The future tasks of nuclear electronics engineers will be increasingly oriented towards designing and building the interfaces between a nuclear experiment and a computer. The manual pays tribute to this development by introducing a number of experiments which illustrate the principles and the technology of interfacing

  10. Intra-observer reliability and agreement of manual and digital orthodontic model analysis.

    Science.gov (United States)

    Koretsi, Vasiliki; Tingelhoff, Linda; Proff, Peter; Kirschneck, Christian

    2018-01-23

    Digital orthodontic model analysis is gaining acceptance in orthodontics, but its reliability is dependent on the digitalisation hardware and software used. We thus investigated intra-observer reliability and agreement / conformity of a particular digital model analysis work-flow in relation to traditional manual plaster model analysis. Forty-eight plaster casts of the upper/lower dentition were collected. Virtual models were obtained with orthoX®scan (Dentaurum) and analysed with ivoris®analyze3D (Computer konkret). Manual model analyses were done with a dial caliper (0.1 mm). Common parameters were measured on each plaster cast and its virtual counterpart five times each by an experienced observer. We assessed intra-observer reliability within method (ICC), agreement/conformity between methods (Bland-Altman analyses and Lin's concordance correlation), and changing bias (regression analyses). Intra-observer reliability was substantial within each method (ICC ≥ 0.7), except for five manual outcomes (12.8 per cent). Bias between methods was statistically significant, but less than 0.5 mm for 87.2 per cent of the outcomes. In general, larger tooth sizes were measured digitally. Total difference maxilla and mandible had wide limits of agreement (-3.25/6.15 and -2.31/4.57 mm), but bias between methods was mostly smaller than intra-observer variation within each method with substantial conformity of manual and digital measurements in general. No changing bias was detected. Although both work-flows were reliable, the investigated digital work-flow proved to be more reliable and yielded on average larger tooth sizes. Averaged differences between methods were within 0.5 mm for directly measured outcomes but wide ranges are expected for some computed space parameters due to cumulative error. © The Author 2017. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

  11. UQTk Version 3.0.3 User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Sargsyan, Khachik [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Safta, Cosmin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Chowdhary, Kamaljit Singh [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Castorena, Sarah [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); De Bord, Sarah [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Debusschere, Bert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-05-01

    The UQ Toolkit (UQTk) is a collection of libraries and tools for the quantification of uncertainty in numerical model predictions. Version 3.0.3 offers intrusive and non-intrusive methods for propagating input uncertainties through computational models, tools for sen- sitivity analysis, methods for sparse surrogate construction, and Bayesian inference tools for inferring parameters from experimental data. This manual discusses the download and installation process for UQTk, provides pointers to the UQ methods used in the toolkit, and describes some of the examples provided with the toolkit.

  12. 14 CFR 121.141 - Airplane flight manual.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airplane flight manual. 121.141 Section 121... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Manual Requirements § 121.141 Airplane flight manual. (a) Each certificate holder shall keep a current approved airplane flight manual for each type of...

  13. Proceedings of the 1. Arabic conference on chemical applications (Chemia 2). Vol. 2

    International Nuclear Information System (INIS)

    1997-11-01

    The conference of chemical application was held on 1-5 Nov 1997 in Cairo, This vol.2 contains of chemical application on nuclear materials. Studies on these vol.This second volume covers papers presented on the subjects

  14. Proceedings of the second international conference on environmental impact assessment of all economical activities. Vol. 2

    International Nuclear Information System (INIS)

    1993-01-01

    Proceedings of the conference consist of 3 volumes: Vol. 1 - 'Environmental Impact Assessment of all Economical Activities including Industry'; Vol. 2 - 'Air Pollution Control and Prevention'; Vol. 3 - Waste Management and Environmental Problems in Construction Industry'. Out of 32 papers contained in Vol. 2, 4 were inputted to INIS. They deal with nuclear fusion as a potential energy source, with environmental aspects of disposal of ashes from power plants in the Czech Republic, and with land reclamation after mining activities. (Z.S.)

  15. Author Details

    African Journals Online (AJOL)

    Achi, PBU. Vol 6, No 1 (1982) - Articles Stepping Motor - Hydraulic Motor Servo Drives for an NC Milling Machine Abstract PDF · Vol 8, No 1 (1984) - Research papers. The Design of a Manual Numerical-Control Circuit for Stepping Motors Abstract PDF · Vol 15, No 1 (1991) - Research papers. Quality Productivity Circle in ...

  16. Infant and Toddler Oral- and Manual-Motor Skills Predict Later Speech Fluency in Autism

    Science.gov (United States)

    Gernsbacher, Morton Ann; Sauer, Eve A.; Geye, Heather M.; Schweigert, Emily K.; Goldsmith, H. Hill

    2008-01-01

    Background: Spoken and gestural communication proficiency varies greatly among autistic individuals. Three studies examined the role of oral- and manual-motor skill in predicting autistic children's speech development. Methods: Study 1 investigated whether infant and toddler oral- and manual-motor skills predict middle childhood and teenage speech…

  17. Do treatment manuals undermine youth–therapist alliance in community clinical practice?

    OpenAIRE

    Langer, David A.; McLeod, Bryce D.; Weisz, John R

    2011-01-01

    Objective: Some critics of treatment manuals have argued that their use may undermine the quality of the client–therapist alliance. This notion was tested in the context of youth psychotherapy delivered by therapists in community clinics. Method: Seventy-six clinically referred youths (57% female, age 8–15 years, 34% Caucasian) were randomly assigned to receive nonmanualized usual care or manual-guided treatment to address anxiety or depressive disorders. Treatment was provided in community c...

  18. Browse Title Index

    African Journals Online (AJOL)

    Items 101 - 150 of 432 ... Vol 13, No 2 (2008), Evidence-based nursing interventions and guidelines ... Vol 9, No 4 (2004), Exercise and depression: A treatment manual, Abstract ... informed health education during comprehensive nursing care ...

  19. Oil Spill Response Manual

    NARCIS (Netherlands)

    Marieke Zeinstra; Sandra Heins; Wierd Koops

    2014-01-01

    A two year programme has been carried out by the NHL University of Applied Sciences together with private companies in the field of oil and chemical spill response to finalize these manuals on oil and chemical spill response. These manuals give a good overview of all aspects of oil and chemical

  20. Manual for conducting radiological surveys in support of license termination

    International Nuclear Information System (INIS)

    Berger, J.D.

    1992-06-01

    This document describes a process for conducting radiological surveys during decommissioning, to demonstrate that residual radioactive material satisfies criteria established by the U.S. Nuclear Regulatory Commission (NRC) for termination of a license. The Manual describes procedures for design and conduct of surveys in a manner which will provide a high degree of assurance that NRC guidelines and conditions have been satisfied. The Manual also describes methods for documenting the survey findings in a final report to the NRC. This Manual updates information contained in NUREG/CR-2082, Monitoring for Compliance with Decommissioning Termination Survey Criteria, (ORNL 1981). It incorporates statistical approaches to survey design and data interpretation used by the Environmental Protection Agency for evaluation of hazardous materials sites under Superfund (CERCLA). Quality assurance is emphasized throughout. (author)

  1. Index to Nuclear Safety. A technical progress review by chronology, permuted title, and author. Vol 11, No. 1 through Vol. 16, No. 6

    International Nuclear Information System (INIS)

    Cottrell, W.B.; Klein, A.

    1976-04-01

    This index to Nuclear Safety covers articles in Nuclear Safety Vol. 11, No. 1 (Jan.-Feb. 1970) through Vol. 16, No. 6 (Nov.-Dec. 1975). Included in the index is a chronological list of articles (including abstract) followed by both a KWIC index and an Author Index. Nuclear Safety is a bimonthly technical progress review prepared by the Nuclear Safety Information Center and covers all safety aspects of nuclear power reactors and associated facilities. The index lists over 300 technical articles in the last six years of publication

  2. Index to Nuclear Safety. A technical progress review by chronology, permuted title, and author. Vol 11, No. 1 through Vol. 16, No. 6

    Energy Technology Data Exchange (ETDEWEB)

    Cottrell, W.B.; Klein, A.

    1976-04-01

    This index to Nuclear Safety covers articles in Nuclear Safety Vol. 11, No. 1 (Jan.-Feb. 1970) through Vol. 16, No. 6 (Nov.-Dec. 1975). Included in the index is a chronological list of articles (including abstract) followed by both a KWIC index and an Author Index. Nuclear Safety is a bimonthly technical progress review prepared by the Nuclear Safety Information Center and covers all safety aspects of nuclear power reactors and associated facilities. The index lists over 300 technical articles in the last six years of publication.

  3. 46 CFR 160.176-21 - User manuals.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false User manuals. 160.176-21 Section 160.176-21 Shipping...: SPECIFICATIONS AND APPROVAL LIFESAVING EQUIPMENT Inflatable Lifejackets § 160.176-21 User manuals. (a) The manufacturer must develop a user's manual for each model of inflatable lifejacket. The content of the manual...

  4. A comparison of automated and manual radioimmunoassays for the estimation of serum digoxin

    International Nuclear Information System (INIS)

    Tuttlebee, J.W.

    1984-01-01

    Digoxin was assayed manually (SPAC kit) and by an automated radioimmunoassay instrument (ARIA II). There was good correlation between the methods (r=0.964; n=120). Carryover by the automated method was marginally significant from low to high level samples (5.2%), but insignificant from high to low level samples (1.4%). The precision on the ARIA II was far better in spite of the fact that assays were performed only in singlets compared with duplicates on the manual procedure. Best precision was obtained at the high level (3.76 nmol/l; between-batch CV: 2.4% ARIA; 5.5% SPAC). All values for control samples (manual and automated) fell within 6% of the all-method means. Using the ARIA II is marginally quicker and significantly cheaper. However, some back-up procedure is required for 'down time' with the machine, for what can be an urgent investigation. Patient results correlated well with clinical data. (orig.) [de

  5. Applicator Training Manual for: Agricultural Animal Pest Control.

    Science.gov (United States)

    Christensen, Christian M.

    This manual discusses pesticide safety and environmental considerations, pesticide toxicity, residue potential, pesticide formulations, and application techniques. In addition, descriptions of, and methods for controlling insects and related pests that attack cattle, sheep and goats, swine, horses and other equines, and poultry are given. These…

  6. Technical Manual: 2002 Series GED Tests

    Science.gov (United States)

    Ezzelle, Carol; Setzer, J. Carl

    2009-01-01

    This manual was written to provide technical information regarding the 2002 Series GED (General Educational Development) Tests. Throughout this manual, documentation is provided regarding the development of the GED Tests, data collection activities, as well as reliability and validity evidence. The purpose of this manual is to provide evidence…

  7. Technical Manual. The ACT®

    Science.gov (United States)

    ACT, Inc., 2014

    2014-01-01

    This manual contains technical information about the ACT® college readiness assessment. The principal purpose of this manual is to document the technical characteristics of the ACT in light of its intended purposes. ACT regularly conducts research as part of the ongoing formative evaluation of its programs. The research is intended to ensure that…

  8. Automatic MRI Quantifying Methods in Behavioral-Variant Frontotemporal Dementia Diagnosis

    Directory of Open Access Journals (Sweden)

    Antti Cajanus

    2018-02-01

    Full Text Available Aims: We assessed the value of automated MRI quantification methods in the differential diagnosis of behavioral-variant frontotemporal dementia (bvFTD from Alzheimer disease (AD, Lewy body dementia (LBD, and subjective memory complaints (SMC. We also examined the role of the C9ORF72-related genetic status in the differentiation sensitivity. Methods: The MRI scans of 50 patients with bvFTD (17 C9ORF72 expansion carriers were analyzed using 6 quantification methods as follows: voxel-based morphometry (VBM, tensor-based morphometry, volumetry (VOL, manifold learning, grading, and white-matter hyperintensities. Each patient was then individually compared to an independent reference group in order to attain diagnostic suggestions. Results: Only VBM and VOL showed utility in correctly identifying bvFTD from our set of data. The overall classification sensitivity of bvFTD with VOL + VBM achieved a total sensitivity of 60%. Using VOL + VBM, 32% were misclassified as having LBD. There was a trend of higher values for classification sensitivity of the C9ORF72 expansion carriers than noncarriers. Conclusion: VOL, VBM, and their combination are effective in differential diagnostics between bvFTD and AD or SMC. However, MRI atrophy profiles for bvFTD and LBD are too similar for a reliable differentiation with the quantification methods tested in this study.

  9. Environment, safety, and health manual, closeout report

    International Nuclear Information System (INIS)

    1975-12-01

    A coordination draft of the Environment, Safety, and Health (ES and H) manual was submitted on 2 September 1975. Comments provided by Operational Safety personnel were being incorporated by a task team when the effort was terminated on 31 October 1975. This report documents the development history of the manual and provides a status of the manual up to the time the efforts were discontinued. Also discussed are issues which effect completion of the manual. Additionally a plan for completion of the manual is suggested

  10. Investigations on the quality of manual image segmentation in 3D radiotherapy planning

    International Nuclear Information System (INIS)

    Perelmouter, J.; Tuebingen Univ.; Bohsung, J.; Nuesslin, F.; Becker, G.; Kortmann, R.D.; Bamberg, M.

    1998-01-01

    In 3D radiotherapy planning image segmentation plays an important role in the definition process of target volume and organs at risk. Here, we present a method to quantify the technical precision of the manual image segmentation process. To validate our method we developed a virtual phantom consisting of several geometrical objects of changing form and contrast, which should be contoured by volunteers using the TOMAS tool for manual segmentation of the Heidelberg VOXELPLAN system. The results of this examination are presented. (orig.) [de

  11. MARS CODE MANUAL VOLUME V: Models and Correlations

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Bae, Sung Won; Lee, Seung Wook; Yoon, Churl; Hwang, Moon Kyu; Kim, Kyung Doo; Jeong, Jae Jun

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This models and correlations manual provides a complete list of detailed information of the thermal-hydraulic models used in MARS, so that this report would be very useful for the code users. The overall structure of the manual is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  12. Marketing Research. Instructor's Manual.

    Science.gov (United States)

    Small Business Administration, Washington, DC.

    Prepared for the Administrative Management Course Program, this instructor's manual was developed to serve small-business management needs. The sections of the manual are as follows: (1) Lesson Plan--an outline of material covered, which may be used as a teaching guide, presented in two columns: the presentation, and a step-by-step indication of…

  13. Indoor Air Quality Manual.

    Science.gov (United States)

    Baldwin Union Free School District, NY.

    This manual identifies ways to improve a school's indoor air quality (IAQ) and discusses practical actions that can be carried out by school staff in managing air quality. The manual includes discussions of the many sources contributing to school indoor air pollution and the preventive planning for each including renovation and repair work,…

  14. 25 CFR 175.5 - Operations manual.

    Science.gov (United States)

    2010-04-01

    ... Provisions § 175.5 Operations manual. (a) The Area Director shall establish an operations manual for the... Director shall amend the operations manual as needed. (b) The public shall be notified by the Area Director... shall be published in local newspaper(s) of general circulation, posted at the utility office(s), and...

  15. AFM-CMM integrated instrument user manual

    DEFF Research Database (Denmark)

    Marinello, Francesco; Bariani, Paolo

    This manual gives general important guidelines for a proper use of the integrated AFM-CMM instrument. More information can be collected reading: • N. Kofod Ph.D thesis [1]; • P. Bariani Ph.D thesis [2]; • Dualscope DME 95-200 operation manuals [3]; • SPIP help [4] • Stitching software user manual...

  16. volBrain: An Online MRI Brain Volumetry System

    Science.gov (United States)

    Manjón, José V.; Coupé, Pierrick

    2016-01-01

    The amount of medical image data produced in clinical and research settings is rapidly growing resulting in vast amount of data to analyze. Automatic and reliable quantitative analysis tools, including segmentation, allow to analyze brain development and to understand specific patterns of many neurological diseases. This field has recently experienced many advances with successful techniques based on non-linear warping and label fusion. In this work we present a novel and fully automatic pipeline for volumetric brain analysis based on multi-atlas label fusion technology that is able to provide accurate volumetric information at different levels of detail in a short time. This method is available through the volBrain online web interface (http://volbrain.upv.es), which is publically and freely accessible to the scientific community. Our new framework has been compared with current state-of-the-art methods showing very competitive results. PMID:27512372

  17. volBrain: an online MRI brain volumetry system

    Directory of Open Access Journals (Sweden)

    Jose V. Manjon

    2016-07-01

    Full Text Available The amount of medical image data produced in clinical and research settings is rapidly growing resulting in vast amount of data to analyze. Automatic and reliable quantitative analysis tools, including segmentation, allow to analyze brain development and to understand specific patterns of many neurological diseases. This field has recently experienced many advances with successful techniques based on non-linear warping and label fusion. In this work we present a novel and fully automatic pipeline for volumetric brain analysis based on multi-atlas label fusion technology that is able to provide accurate volumetric information at different levels of detail in a short time. This method is available through the volBrain online web interface (http://volbrain.upv.es, which is publically and freely accessible to the scientific community. Our new framework has been compared with current state-of-the-art methods showing very competitive results.

  18. volBrain: An Online MRI Brain Volumetry System.

    Science.gov (United States)

    Manjón, José V; Coupé, Pierrick

    2016-01-01

    The amount of medical image data produced in clinical and research settings is rapidly growing resulting in vast amount of data to analyze. Automatic and reliable quantitative analysis tools, including segmentation, allow to analyze brain development and to understand specific patterns of many neurological diseases. This field has recently experienced many advances with successful techniques based on non-linear warping and label fusion. In this work we present a novel and fully automatic pipeline for volumetric brain analysis based on multi-atlas label fusion technology that is able to provide accurate volumetric information at different levels of detail in a short time. This method is available through the volBrain online web interface (http://volbrain.upv.es), which is publically and freely accessible to the scientific community. Our new framework has been compared with current state-of-the-art methods showing very competitive results.

  19. Regulations and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Young, Lydia J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2011-07-25

    The purpose of the Regulations and Procedures Manual (RPM) is to provide LBNL personnel with a reference to University and Lawrence Berkeley National Laboratory (LBNL or Laboratory) policies and regulations by outlining normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory organizations. Much of the information in this manual has been condensed from detail provided in LBNL procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. RPM sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the LBNL organization responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which organization is responsible for a policy, please contact Requirements Manager Lydia Young or the RPM Editor.

  20. Regulations and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Young, Lydia [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2010-09-30

    The purpose of the Regulations and Procedures Manual (RPM) is to provide Laboratory personnel with a reference to University and Lawrence Berkeley National Laboratory policies and regulations by outlining the normal practices and answering most policy questions that arise in the day-to-day operations of Laboratory departments. Much of the information in this manual has been condensed from detail provided in Laboratory procedure manuals, Department of Energy (DOE) directives, and Contract DE-AC02-05CH11231. This manual is not intended, however, to replace any of those documents. The sections on personnel apply only to employees who are not represented by unions. Personnel policies pertaining to employees represented by unions may be found in their labor agreements. Questions concerning policy interpretation should be directed to the department responsible for the particular policy. A link to the Managers Responsible for RPM Sections is available on the RPM home page. If it is not clear which department should be called, please contact the Associate Laboratory Director of Operations.

  1. Manual for subject analysis

    International Nuclear Information System (INIS)

    2002-01-01

    This document is one in a series of publications known as the ETDE/INIS Joint Reference Series and also constitutes a part of the ETDE Procedures Manual. It presents the rules, guidelines and procedures to be adopted by centers submitting input to the International Nuclear Information System (INIS) or the Energy Technology Data Exchange (ETDE). It is a manual for the subject analysis part of input preparation, meaning the selection, subject classification, abstracting and subject indexing of relevant publications, and is to be used in conjunction with the Thesauruses, Subject Categories documents and the documents providing guidelines for the preparation of abstracts. The concept and structure of the new manual are intended to describe in a logical and efficient sequence all the steps comprising the subject analysis of documents to be reported to INIS or ETDE. The manual includes new chapters on preparatory analysis, subject classification, abstracting and subject indexing, as well as rules, guidelines, procedures, examples and a special chapter on guidelines and examples for subject analysis in particular subject fields. (g.t.; a.n.)

  2. Laboratory training manual on radioimmunoassay in animal reproduction

    International Nuclear Information System (INIS)

    1984-01-01

    Reproduction must always be regarded as one of the major limiting factors in animal production and many of the modern methods for improving reproduction rely heavily on the ability to measure hormone levels in blood and milk. This has produced a world-wide demand for laboratory facilities to carry out hormone assays and the need for specialist training to allow these assays to be undertaken. The need to measure nanogram and picogram quantities and the use of radionuclides require a good deal of skill and care and this Manual has been prepared to aid training and provide the sort of information that rarely appears in scientific papers. It represents a further step in the Joint FAO/IAEA Division's series of Laboratory Training Manuals, and has been designed to aid training programmes of the type carried out during the Joint FAO/IAEA Interregional Training Course on Radioimmunoassay and its Application in Research on Animal Reproduction at Cornell University in July 1982. Many of the laboratory exercises described in this Manual are based on those conducted during the course

  3. The influence of image setting on intracranial translucency measurement by manual and semi-automated system.

    Science.gov (United States)

    Zhen, Li; Yang, Xin; Ting, Yuen Ha; Chen, Min; Leung, Tak Yeung

    2013-09-01

    To investigate the agreement between manual and semi-automated system and the effect of different image settings on intracranial translucency (IT) measurement. A prospective study was conducted on 55 women carrying singleton pregnancy who attended first trimester Down syndrome screening. IT was measured both manually and by semi-automated system at the same default image setting. The IT measurements were then repeated with the post-processing changes in the image setting one at a time. The difference in IT measurements between the altered and the original images were assessed. Intracranial translucency was successfully measured on 55 images both manually and by semi-automated method. There was strong agreement in IT measurements between the two methods with a mean difference (manual minus semi-automated) of 0.011 mm (95% confidence interval--0.052 mm-0.094 mm). There were statistically significant variations in both manual and semi-automated IT measurement after changing the Gain and the Contrast. The greatest changes occurred when the Contrast was reduced to 1 (IT reduced by 0.591 mm in semi-automated; 0.565 mm in manual), followed by when the Gain was increased to 15 (IT reduced by 0.424 mm in semi-automated; 0.524 mm in manual). The image settings may affect IT identification and measurement. Increased Gain and reduced Contrast are the most influential factors and may cause under-measurement of IT. © 2013 John Wiley & Sons, Ltd.

  4. MAP user's manual copyright

    International Nuclear Information System (INIS)

    Pillsbury, R.D. Jr.

    1991-12-01

    The program MITMAP represents a set of general purpose, two- dimensional, finite element programs for the calculation of magnetic fields. It consists of the program MAP and MAP2DJ. The two programs are used to solve different electromagnetic problems, but they have a common set of subrountines for pre- and postprocessing. Originally separate programs, they have been combined to make modification easier. The manuals, however, will remain separate. The program MAP is described in this manual. MAP is applicable to the class of problems with two-dimensional-planar or axisymmetric - geometries, in which the current density and the magnetic vector potential have only a single nonvanishing component. The single component is associated with the direction that is perpendicular to the plane of the problem and is invariant with respect to that direction. Maxwell's equations can be reduced to a solver diffusion equation in terms of the single, nonvanishing component of the magnetic vector potential for planar problems and to a single component of a vector potential for planar problems and to a single component of a vector diffusion equation for axisymmetric problems. The magnetic permeability appears in the governing equation. The permeability may be a function of the magnetic flux density. In addition, any electrically conducting material present will have eddy currents induced by a time varying magnetic field. These eddy currents must be included in the solution process. This manual provides a description of the structure of the input data and output for the program. There are several example problems presented that illustrate the major program features. Appendices are included that contain a derivation of the governing equations and the application of the finite element method to the solution of the equations

  5. Integrated Fuel-Coolant Interaction (IFCI 7.0) Code User's Manual

    International Nuclear Information System (INIS)

    Young, Michael F.

    1999-01-01

    The integrated fuel-coolant interaction (IFCI) computer code is being developed at Sandia National Laboratories to investigate the fuel-coolant interaction (FCI) problem at large scale using a two-dimensional, three-field hydrodynamic framework and physically based models. IFCI will be capable of treating all major FCI processes in an integrated manner. This document is a description of IFCI 7.0. The user's manual describes the hydrodynamic method and physical models used in IFCI 7.0. Appendix A is an input manual provided for the creation of working decks

  6. Reconceptualising manual therapy skills in contemporary practice.

    Science.gov (United States)

    Rabey, Martin; Hall, Toby; Hebron, Clair; Palsson, Thorvaldur Skuli; Christensen, Steffan Wittrup; Moloney, Niamh

    2017-06-01

    With conflicting evidence regarding the effectiveness of manual therapy calls have arisen within some quarters of the physiotherapy profession challenging the continued use of manual skills for assessment and treatment. A reconceptualisation of the importance of manual examination findings is put forward, based upon a contemporary understanding of pain science, rather than considering these skills only in terms of how they should "guide" manual therapy interventions. The place for manual examination findings within complex, multidimensional presentations is considered using vignettes describing the presentations of five people with low back pain. As part of multidimensional, individualised management, the balance of evidence relating to the effectiveness, mechanisms of action and rationale for manual skills is discussed. It is concluded that if manual examination and therapeutic skills are used in a manner consistent with a contemporary understanding of pain science, multidimensional patient profiles and a person-centred approach, their selective and judicious use still has an important role. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Mars 2.2 code manual: input requirements

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Lee, Won Jae; Jeong, Jae Jun; Lee, Young Jin; Hwang, Moon Kyu; Kim, Kyung Doo; Lee, Seung Wook; Bae, Sung Won

    2003-07-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This input manual provides a complete list of input required to run MARS. The manual is divided largely into two parts, namely, the one-dimensional part and the multi-dimensional part. The inputs for auxiliary parts such as minor edit requests and graph formatting inputs are shared by the two parts and as such mixed input is possible. The overall structure of the input is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS. MARS development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  8. MARS code manual volume II: input requirements

    International Nuclear Information System (INIS)

    Chung, Bub Dong; Kim, Kyung Doo; Bae, Sung Won; Jeong, Jae Jun; Lee, Seung Wook; Hwang, Moon Kyu

    2010-02-01

    Korea Advanced Energy Research Institute (KAERI) conceived and started the development of MARS code with the main objective of producing a state-of-the-art realistic thermal hydraulic systems analysis code with multi-dimensional analysis capability. MARS achieves this objective by very tightly integrating the one dimensional RELAP5/MOD3 with the multi-dimensional COBRA-TF codes. The method of integration of the two codes is based on the dynamic link library techniques, and the system pressure equation matrices of both codes are implicitly integrated and solved simultaneously. In addition, the Equation-Of-State (EOS) for the light water was unified by replacing the EOS of COBRA-TF by that of the RELAP5. This input manual provides a complete list of input required to run MARS. The manual is divided largely into two parts, namely, the one-dimensional part and the multi-dimensional part. The inputs for auxiliary parts such as minor edit requests and graph formatting inputs are shared by the two parts and as such mixed input is possible. The overall structure of the input is modeled on the structure of the RELAP5 and as such the layout of the manual is very similar to that of the RELAP. This similitude to RELAP5 input is intentional as this input scheme will allow minimum modification between the inputs of RELAP5 and MARS3.1. MARS3.1 development team would like to express its appreciation to the RELAP5 Development Team and the USNRC for making this manual possible

  9. BLOCKAGE 2.5 reference manual

    International Nuclear Information System (INIS)

    Shaffer, C.J.; Brideau, J.; Rao, D.V.; Bernahl, W.

    1996-12-01

    The BLOCKAGE 2.5 code was developed by the US Nuclear Regulatory Commission (NRC) as a tool to evaluate license compliance regarding the design of suction strainers for emergency core cooling system (ECCS) pumps in boiling water reactors (BWR) as required by NRC Bulletin 96-03, ''Potential Plugging of Emergency Core Cooling Suction Strainers by Debris in Boiling Water Reactors''. Science and Engineering Associates, Inc. (SEA) and Software Edge, Inc. (SE) developed this PC-based code. The instructions to effectively use this code to evaluate the potential of debris to sufficiently block a pump suction strainer such that a pump could lose NPSH margin was documented in a User's Manual (NRC, NUREG/CR-6370). The Reference Manual contains additional information that supports the use of BLOCKAGE 2.5. It contains descriptions of the analytical models contained in the code, programmer guides illustrating the structure of the code, and summaries of coding verification and model validation exercises that were performed to ensure that the analytical models were correctly coded and applicable to the evaluation of BWR pump suction strainers. The BLOCKAGE code was developed by SEA and programmed in FORTRAN as a code that can be executed from the DOS level on a PC. A graphical users interface (GUI) was then developed by SEA to make BLOCKAGE easier to use and to provide graphical output capability. The GUI was programmed in the C language. The user has the option of executing BLOCKAGE 2.5 with the GUI or from the DOS level and the Users Manual provides instruction for both methods of execution

  10. Manual for guided home exercises for osteoarthritis of the knee

    Directory of Open Access Journals (Sweden)

    Nilza Aparecida de Almeida Carvalho

    2010-06-01

    Full Text Available INTRODUCTION: Physiotherapy is one of the most important components of therapy for osteoarthritis of the knee. The objective of this prospective case series was to assess the efficiency of a guidance manual for patients with osteoarthritis of the knee in relation to pain, range of movement , muscle strength and function, active goniometry, manual strength test and function. METHODS: Thirty-eight adults with osteoarthritis of the knee (> 45 years old who were referred to the physiotherapy service at the university hospital (Santa Casa de Misericórdia de São Paulo were studied. Patients received guidance for the practice of specific physical exercises and a manual with instructions on how to perform the exercises at home. They were evaluated for pain, range of movement, muscle strength and function. These evaluations were performed before they received the manual and three months later. Patients were seen monthly regarding improvements in their exercising abilities. RESULTS: The program was effective for improving muscle strength, controlling pain, maintaining range of movement of the knee joint, and reducing functional incapacity. DISCUSSION: A review of the literature showed that there are numerous clinical benefits to the regular practice of physical therapy exercises by patients with osteoarthritis of the knee(s in a program with appropriate guidance. This study shows that this guidance can be attained at home with the use of a proper manual. CONCLUSIONS: Even when performed at home without constant supervision, the use of the printed manual for orientation makes the exercises for osteoarthritis of the knee beneficial.

  11. TRUBA User Manual

    International Nuclear Information System (INIS)

    Tereshchenko, M. A.; Castejon, F.; Cappa, A.

    2008-01-01

    The TRUBA (pipeline in Russian) code is a computational tool for studying the propagation of Gaussian-shaped microwave beams in a prescribed equilibrium plasma. This manual covers the basic material handed to use the implementation of TRUBA (version 3,4) interfaced with the numerical library of the TJ-II stellarator. The manual provides a concise theoretical background of the problem, specifications for setting up the input files and interpreting the output of the code, and some information useful in modifying TRUBA. (Author) 13 refs

  12. TRUBA User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Tereshchenko, M. A.; Castejon, F.; Cappa, A.

    2008-04-25

    The TRUBA (pipeline in Russian) code is a computational tool for studying the propagation of Gaussian-shaped microwave beams in a prescribed equilibrium plasma. This manual covers the basic material handed to use the implementation of TRUBA (version 3,4) interfaced with the numerical library of the TJ-II stellarator. The manual provides a concise theoretical background of the problem, specifications for setting up the input files and interpreting the output of the code, and some information useful in modifying TRUBA. (Author) 13 refs.

  13. Developing a Pupil Transportation Manual.

    Science.gov (United States)

    Douglas, Dave

    1987-01-01

    District-level pupil transportation manuals that contain clear, concise information about objectives, policies, and regulations are a must. These manuals should also specify procedures concerning evaluation processes, personnel recruitment and selection, and the driver training program. (MLH)

  14. Fast Reactor Physics. Vol. II. Proceedings of a Symposium on Fast Reactor Physics and Related Safety Problems

    International Nuclear Information System (INIS)

    1968-01-01

    Proceedings of a Symposium organized by the IAEA and held in Karlsruhe, 30 October - 3 November 1967. The meeting was attended by 183 scientists from 23 countries and three international organizations. Contents: (Vol.1) Review of national programmes (5 papers); Nuclear data for fast reactors (12 papers); Experimental methods (3 papers); Zoned systems (7 papers); Kinetics (7 papers). (Vol.11) Fast critical experiments (8 papers); Heterogeneity in fast critical experiments (5 papers); Fast power reactors (13 papers); Fast pulsed reactors (3 papers); Panel discussion. Each paper is in its original language (50 English, 11 French and 3 Russian) and is preceded by an abstract in English with a second one in the original language if this is not English. Discussions are in English. (author)

  15. Missouri Highway Safety Manual Recalibration

    Science.gov (United States)

    2018-05-01

    The Highway Safety Manual (HSM) is a national manual for analyzing the highway safety of various facilities, including rural roads, urban arterials, freeways, and intersections. The HSM was first published in 2010, and a 2014 supplement addressed fre...

  16. Proceedings of the second international conference on environmental impact assessment of all economical activities. Vol. 3

    International Nuclear Information System (INIS)

    1993-01-01

    Proceedings of the conference consist of 3 volumes: Vol. 1 - 'Environmental Impact Assessment of all Economical Activities including Industry'; Vol. 2 - 'Air Pollution Control and Prevention'; Vol. 3 - Waste Management and Environmental Problems in Construction Industry'. Out of 39 papers contained in Vol. 3, 3 were inputted to INIS. They deal with the use of portable radioisotope X-ray fluorescence analyzers in the determination of building material contamination by toxic elements, with underground waste repositories and ground water contamination, and the impact of the Temelin nuclear power plant on the hydrosphere and other environmental components. (Z.S.)

  17. Rotorcraft Airloads Measurements - Extraordinary Costs, Extraordinary Benefits

    Science.gov (United States)

    2014-08-01

    Force at High Speed—Data Analysis. NASA CR 145217-1. Merkley, D. J., M. J. Riley, and C. Young. 1983. Summary Report of the Second TTCP/ HTP -6 Joint...Philbrick, R. B. 1980. The Data from Aeromechanics Test and Analytics—Management and Analysis Package (DATAMAP), Vol. 1 – User’s Manual . USAAVRADCOM- TR-80...D-30A. Philbrick, R. B. and A. L. Eubanks. 1979. Operational Loads Survey – Data Management System, Vol. 1 User’s Manual . USARTL TR 78-52A. Piziali

  18. Manual on mutation breeding. 2. ed.

    International Nuclear Information System (INIS)

    1977-01-01

    The manual is a compilation of work done on the use of induced mutations in plant breeding, and presents general methods and techniques in this field. The use of chemical mutagens and ionizing radiations (X-rays, gamma rays, α- and β-particles, protons, neutrons) are described as well as the effects of these mutagens. The different types of mutations achieved can be divided into genome mutations, chromosome mutations and extra nuclear mutations. Separate chapters deal with mutation techniques in breeding seed-propagated species and asexually propagated plants (examples of development of cultivars given). Plant characters which can be improved by mutation breeding include yield, ripening time, growth habit, disease resistance and tolerance to environmental factors (temperature, salinity etc.). The use of mutagens for some specific plant breeding problems is discussed and attention is also paid to somatic cell genetics in connection with induced mutations. The manual contains a comprehensive bibliography (60 p. references) and a subject index

  19. AJESMS_ Vol 8 2010 August 15 2011

    African Journals Online (AJOL)

    Prof. Mereku

    2010-08-15

    Aug 15, 2010 ... African Journal of Educational Studies in Mathematics and Sciences Vol. 8, 2010 ... environs, a mining area in Wassa West District of Ghana .... This finding is based on autopsy data and on reports showing that blood levels in.

  20. Water SA - Vol 30, No 3 (2004)

    African Journals Online (AJOL)

    Application of a residential end-use model for estimating cold and hot water demand ... of multistage filtration using different filter media against conventional water ... (Germs et al., 2004), published in the April 2004 (Vol 30 No 2) issue of Water ...

  1. Autoaspiration versus manual aspiration in transbronchial needle aspiration in diagnosis of intrathoracic lymphadenopathy.

    Science.gov (United States)

    Boonsarngsuk, Viboon; Pongtippan, Atcharaporn; Juthakarn, Sabaitip; Boonsarngsuk, Wison; Kurimoto, Noriaki

    2009-10-01

    Traditionally, aspiration with high negative pressure is recommended to obtain a specimen in transbronchial needle aspiration (TBNA). Undeniably, however, the assistant experiences difficulty in the generation of the negative pressure and precise control of the syringe while performing the procedure. To evaluate the effectiveness of the autoaspiration method created by our plunger lock in comparison with the conventional manual aspiration in the diagnosis of intrathoracic lymphadenopathy by TBNA. A prospective study was conducted on all patients referred for diagnostic TBNA of enlarged intrathoracic lymph nodes. Both automatic and manual aspiration techniques were performed after the needle had been completely inserted into the nodes. The diagnostic yield and the numbers of diagnostic cells or benign lymphoid cells obtained by each technique were compared in the same node. A total of 31 intrathoracic lymph nodes in 24 patients were prospectively studied. Twenty-four nodes (77.4%) were malignancies whereas 7 nodes (22.6%) were benign disease. Adequate lymph node samples were obtained in 30 targets (96.8%), and TBNA revealed definite diagnosis for 25 nodes (80.6%). Both aspiration techniques showed exactly the same diagnostic yield. However, the autoaspiration technique provided significantly more adequate samples than manual aspiration techniques did (P=0.003). The autoaspiration method using our plunger lock was superior to the manual method in obtaining the numbers of adequate samples in TBNA procedures.

  2. Preprocedural ultrasound examination versus manual palpation for thoracic epidural catheter insertion

    Directory of Open Access Journals (Sweden)

    Ahmed M Hasanin

    2017-01-01

    Conclusion: Preprocedural ultrasound imaging increased the incidence of first pass success in thoracic epidural catheter insertion and reduced the catheter insertion time compared to manual palpation method.

  3. Correlação da aferição manual e digital da distância interespinhosa pelo método de newmann em fraturas toracolombares do tipo explosão Correlación entre calibrado manual y digital de la distancia interespinhosa por el método de neumann en fracturas toracolombares tipo explosión Correlation between manual and digital measurement of inter-spinous dis tance by neumann method in burst thoracolumbar fracture

    Directory of Open Access Journals (Sweden)

    João Paulo Machado Bergamaschi

    2011-01-01

    Full Text Available OBJETIVO: Analisar a correlação entre a aferição manual e digital da distância interespinhosa pelo método de Neumann em fraturas toracolombares do tipo explosão, bem como a reprodutibilidade das duas técnicas. MÉTODOS: Foram avaliadas 212 radiografias de pacientes com fratura toracolombar do tipo explosão, sendo 160 do sexo masculino e 52 do sexo feminino. A idade média dos pacientes no tempo da fratura foi de 38,9 anos (variando de 12 a 76 anos. RESULTADOS: O coeficiente de Pearson, quando comparados os valores percentuais manuais e digitais da relação da distância interespinhosa do nível da vértebra fraturada e dos níveis adjacentes, foi de 0,95 (pOBJETIVO: El objetivo de este estudio es analizar la correlación entre calibrado manual y digital de la distancia interespinhosa por el método de Neumann en fracturas toracolombares tipo explosión, así como la reproducibilidad de los dos técnicas. MÉTODOS: Radiografías fueron evaluados 212 pacientes con fractura toracolombar tipo explosión, 160 hombres y 52 mujeres. La edad promedio de los pacientes en el momento de fractura fue 38.9 años (que van desde 12 a 76 años. RESULTADOS: El coeficiente de Pearson, cuando se comparan valores porcentuales digital y manuales de la relación de distancia interespinhosa el nivel de la vértebra fraturada y niveles adyacentes, fue 0.95 (pOBJECTIVE: The aim of this study is to analyze the correlation between the manual and digital inter-spinous distance by the Neumann method in burst thoracolumbar fracture, as well as the reproducibility of these two techniques. METHODS: We evaluated 212 x-rays of patients with burst thoracolumbar fracture. There were 60 male and 52 female. The average age at the time of the fracture was 38,9 years (12 - 76 years. RESULTS: The Pearson' coefficient between manual and digital analyses was 0,95 (p<0,01. The agreement coefficient of manual and digital measurements was 0,97 and 0,93, respectively. CONCLUSION

  4. Manual on mathematical models in isotope hydrogeology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-10-01

    Methodologies based on the use of naturally occurring isotopes are, at present, an integral part of studies being undertaken for water resources assessment and management. Quantitative evaluations based on the temporal and/or spatial distribution of different isotopic species in hydrological systems require conceptual mathematical formulations. Different types of model can be employed depending on the nature of the hydrological system under investigation, the amount and type of data available, and the required accuracy of the parameter to be estimated. This manual provides an overview of the basic concepts of existing modelling approaches, procedures for their application to different hydrological systems, their limitations and data requirements. Guidance in their practical applications, illustrative case studies and information on existing PC software are also included. While the subject matter of isotope transport modelling and improved quantitative evaluations through natural isotopes in water sciences is still at the development stage, this manual summarizes the methodologies available at present, to assist the practitioner in the proper use within the framework of ongoing isotope hydrological field studies. In view of the widespread use of isotope methods in groundwater hydrology, the methodologies covered in the manual are directed towards hydrogeological applications, although most of the conceptual formulations presented would generally be valid. Refs, figs, tabs.

  5. Manual on mathematical models in isotope hydrogeology

    International Nuclear Information System (INIS)

    1996-10-01

    Methodologies based on the use of naturally occurring isotopes are, at present, an integral part of studies being undertaken for water resources assessment and management. Quantitative evaluations based on the temporal and/or spatial distribution of different isotopic species in hydrological systems require conceptual mathematical formulations. Different types of model can be employed depending on the nature of the hydrological system under investigation, the amount and type of data available, and the required accuracy of the parameter to be estimated. This manual provides an overview of the basic concepts of existing modelling approaches, procedures for their application to different hydrological systems, their limitations and data requirements. Guidance in their practical applications, illustrative case studies and information on existing PC software are also included. While the subject matter of isotope transport modelling and improved quantitative evaluations through natural isotopes in water sciences is still at the development stage, this manual summarizes the methodologies available at present, to assist the practitioner in the proper use within the framework of ongoing isotope hydrological field studies. In view of the widespread use of isotope methods in groundwater hydrology, the methodologies covered in the manual are directed towards hydrogeological applications, although most of the conceptual formulations presented would generally be valid. Refs, figs, tabs

  6. LCS Users Manual

    International Nuclear Information System (INIS)

    Redd, A.J.; Ignat, D.W.

    1998-01-01

    The Lower Hybrid Simulation Code (LSC) is a computational model of lower hybrid current drive in the presence of an electric field. Details of geometry, plasma profiles, and circuit equations are treated. Two-dimensional velocity space effects are approximated in a one-dimensional Fokker-Planck treatment. The LSC was originally written to be a module for lower hybrid current drive called by the Tokamak Simulation Code (TSC), which is a numerical model of an axisymmetric tokamak plasma and the associated control systems. The TSC simulates the time evolution of a free boundary plasma by solving the MHD equations on a rectangular computational grid. The MHD equations are coupled to the external circuits (representing poloidal field coils) through the boundary conditions. The code includes provisions for modeling the control system, external heating, and fusion heating. The LSC module can also be called by the TRANSP code. TRANSP represents the plasma with an axisymmetric, fixed-boundary model and focuses on calculation of plasma transport to determine transport coefficients from data on power inputs and parameters reached. This manual covers the basic material needed to use the LSC. If run in conjunction with TSC, the ''TSC Users Manual'' should be consulted. If run in conjunction with TRANSP, on-line documentation will be helpful. A theoretical background of the governing equations and numerical methods is given. Information on obtaining, compiling, and running the code is also provided

  7. Manual for troubleshooting and upgrading of neutron generators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    This manual is intended to assist operators in troubleshooting and upgrading of neutron generators. It is directed particularly to operators and technicians in less experienced laboratories and therefore the descriptions of the principles and techniques of these machines are operator oriented. In addition to a discussion of the main characteristics of neutron generators, detailed information is given on the function of particular commercial units, on common problems related to specific components of accelerators, and on methods of troubleshooting and repair. Detailed schematic and circuit diagrams are provided to help operators in the development and improvement of the generators. The problems treated in the Manual have been collected during several IAEA missions in developing countries. 125 refs, 161 figs, 22 tabs.

  8. Manual for troubleshooting and upgrading of neutron generators

    International Nuclear Information System (INIS)

    1996-11-01

    This manual is intended to assist operators in troubleshooting and upgrading of neutron generators. It is directed particularly to operators and technicians in less experienced laboratories and therefore the descriptions of the principles and techniques of these machines are operator oriented. In addition to a discussion of the main characteristics of neutron generators, detailed information is given on the function of particular commercial units, on common problems related to specific components of accelerators, and on methods of troubleshooting and repair. Detailed schematic and circuit diagrams are provided to help operators in the development and improvement of the generators. The problems treated in the Manual have been collected during several IAEA missions in developing countries. 125 refs, 161 figs, 22 tabs

  9. Diagnostic and treatment manual of urological cancer

    International Nuclear Information System (INIS)

    Paz y Mino, Milton; Tafur, Fausto; Cornejo, Francisco; Gaibor, Jose; Bueno, Cesar; Basantes, Amparito

    2004-01-01

    This book compiles different opinions about researches, diagnosis, methods, procedures and treatment of urological cancer, which will be useful for physicians and specialists of this illness. This manual is well structured in eight chapters with references, illustrations, figures and tables about neoplasms of kidney, urinary tract, urogenital system. This document is a bibliographic revision about ecuadorian experience in urological cancer

  10. ECONOMICS OF ALEXANDER THE GREAT (15 vols + 4 cdroms) by Gregory Zorzos

    OpenAIRE

    Gregory Zorzos

    2002-01-01

    Research contains many ancient texts (Ancient Greek, Hebrews, Hieroglyphs, Assyrian, Sumerian, Babylonian, Latin, etc.). 1. (MICRO-MACRO ECONOMICS OF ALEXANDER THE GREAT (5 vols + cdrom). Microeconomics and macroeconomics of Alexander the Great. Economic theories, feasibilities, economic plannings, general description of the campaign's business plan etc. 2. BANKS OF ALEXANDER THE GREAT (2 vols + cdrom) Describes banking system, economists, financiers, investors, accountants, bookkeepers, etc,...

  11. Reconceptualising manual therapy skills in contemporary practice

    DEFF Research Database (Denmark)

    Rabey, Martin; Hall, Toby; Hebron, Clair

    2017-01-01

    With conflicting evidence regarding the effectiveness of manual therapy calls have arisen within some quarters of the physiotherapy profession challenging the continued use of manual skills for assessment and treatment. A reconceptualisation of the importance of manual examination findings is put...

  12. New highway accident location manual for Missouri.

    Science.gov (United States)

    2013-12-01

    The Missouri HAL manual is used to identify, analyze, and correct high crash locations, and has not been updated since : 1999. This new edition brings the manual up to date, while incorporating the methodology of the national Highway Safety : Manual ...

  13. Solar control window film: report and manual

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-01

    A method has been developed by which the energy and energy cost savings associated with application of solar control film to windows of commercial and institutional buildings can be calculated. This method has been prepared as a separate, self-contained user's manual. It is simple and essentially non-technical, based on Toronto conditions, and is sufficiently accurate to provide a basis for economic feasibility analysis. The report explains the method in depth and compares it to alternate methods developed by the solar film industry. Variables which affect film performance, the savings that result, and limitations on the use of solar film as an energy conserving method are discussed. 8 refs., 2 figs., 1 tab.

  14. Aircraft operations management manual

    Science.gov (United States)

    1992-01-01

    The NASA aircraft operations program is a multifaceted, highly diverse entity that directly supports the agency mission in aeronautical research and development, space science and applications, space flight, astronaut readiness training, and related activities through research and development, program support, and mission management aircraft operations flights. Users of the program are interagency, inter-government, international, and the business community. This manual provides guidelines to establish policy for the management of NASA aircraft resources, aircraft operations, and related matters. This policy is an integral part of and must be followed when establishing field installation policy and procedures covering the management of NASA aircraft operations. Each operating location will develop appropriate local procedures that conform with the requirements of this handbook. This manual should be used in conjunction with other governing instructions, handbooks, and manuals.

  15. ETAP user's manual

    International Nuclear Information System (INIS)

    Watanabe, Norio; Higuchi, Suminori.

    1990-11-01

    The event tree analysis technique has been used in Probabilistic Safety Assessment for LWRs to delineate various accident scenarios leading to core melt or containment failure and to evaluate their frequencies. This technique often requires manual preparation of event trees with iterative process and time-consuming work in data handling. For the purpose of reducing manual efforts in event tree analysis, we developed a new software package named ETAP (Event Tree Analysis Supporting Program) for event tree analysis. ETAP is an interactive PC-based program which has the ability to construct, update, document, and quantify event trees. Because of its fast running capability to quantify event trees, use of the EATP program can make it easy to perform the sensitivity studies on a variety of system/containment performance issues. This report provides a user's manual for ETAP, which describes the structure, installation, and use of EATP. This software runs on NEC/PC-9800 or compatible PCs that have a 640 KB memory and MS-DOS 2.11 or higher. (author)

  16. OASIS User Manual

    CERN Document Server

    Bojtar, L

    2009-01-01

    The OASIS system has been operational for years now. After a long development the project has reached a state where the number of features it provides exceeds largely what most of its users knows about. The author felt it was time to write a user manual explaining all the functionality of the viewer application. This document is a user manual, concentrating on the functionality of the viewer from the user’s point of view. There are already documents available on the project’s web site about the technical aspects at http://project-oasis.web.cern.ch/project-oasis/presentations.htm . There was an attempt to produce a tutorial on the viewer, but it didn’t get much further than the table of contents, that however is well thought. The structure of this user manual follows the same principle, the basic and most often used features are grouped together. Advanced or less often used features are described in a separate chapter. There is a second organizational principle, features belong to different levels: chann...

  17. Manually controlled neutron-activation system

    International Nuclear Information System (INIS)

    Johns, R.A.; Carothers, G.A.

    1982-01-01

    A manually controlled neutron activation system, the Manual Reactor Activation System, was designed and built and has been operating at one of the Savannah River Plant's production reactors. With this system, samples can be irradiated for up to 24 hours and pneumatically transferred to a shielded repository for decay until their activity is low enough for them to be handled at a radiobench. The Manual Reactor Activation System was built to provide neutron activation of solid waste forms for the Alternative Waste Forms Leach Testing Program. Neutron activation of the bulk sample prior to leaching permits sensitive multielement radiometric analyses of the leachates

  18. The minimal manual: is less really more?

    NARCIS (Netherlands)

    Lazonder, Adrianus W.; van der Meij, Hans

    1993-01-01

    Carroll, Smith-Kerker, Ford and Mazur-Rimetz (The minimal manual, Human-Computer Interaction , 3, 123-153, 1987) have introduced the minimal manual as an alternative to standard self-instruction manuals. While their research indicates strong gains, only a few attempts have been made to validate

  19. MPACT Theory Manual, Version 2.2.0

    Energy Technology Data Exchange (ETDEWEB)

    Downar, Thomas [Univ. of Michigan, Ann Arbor, MI (United States); Collins, Benjamin S. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Gehin, Jess C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Godfrey, Andrew T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Jabaay, Daniel [Univ. of Michigan, Ann Arbor, MI (United States); Kelley, Blake W. [Univ. of Michigan, Ann Arbor, MI (United States); Clarno, Kevin T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kim, Kang [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kochunas, Brendan [Univ. of Michigan, Ann Arbor, MI (United States); Larsen, Edward W. [Univ. of Michigan, Ann Arbor, MI (United States); Liu, Yuxuan [Univ. of Michigan, Ann Arbor, MI (United States); Liu, Zhouyu [Univ. of Michigan, Ann Arbor, MI (United States); Martin, William R. [Univ. of Michigan, Ann Arbor, MI (United States); Palmtag, Scott [Core Physics, Inc., Cary, NC (United States); Rose, Michael [Univ. of Michigan, Ann Arbor, MI (United States); Saller, Thomas [Univ. of Michigan, Ann Arbor, MI (United States); Stimpson, Shane [Univ. of Michigan, Ann Arbor, MI (United States); Trahan, Travis [Univ. of Michigan, Ann Arbor, MI (United States); Wang, J. W. [Univ. of Michigan, Ann Arbor, MI (United States); Wieselquist, William A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Young, Mitchell [Univ. of Michigan, Ann Arbor, MI (United States); Zhu, Ang [Univ. of Michigan, Ann Arbor, MI (United States)

    2016-06-09

    This theory manual describes the three-dimensional (3-D) whole-core, pin-resolved transport calculation methodology employed in the MPACT code. To provide sub-pin level power distributions with sufficient accuracy, MPACT employs the method of characteristics (MOC) solutions in the framework of a 3-D coarse mesh finite difference (CMFD) formulation. MPACT provides a 3D MOC solution, but also a 2D/1D solution in which the 2D planar solution is provided by MOC and the axial coupling is resolved by one-dimensional (1-D) lower order (diffusion or P3) solutions. In Chapter 2 of the manual, the MOC methodology is described for calculating the regional angular and scalar fluxes from the Boltzmann transport equation. In Chapter 3, the 2D/1D methodology is described, together with the description of the CMFD iteration process involving dynamic homogenization and solution of the multigroup CMFD linear system. A description of the MPACT depletion algorithm is given in Chapter 4, followed by a discussion of the subgroup and ESSM resonance processing methods in Chapter 5. The final Chapter 6 describes a simplified thermal hydraulics model in MPACT.

  20. Gender and Behaviour - Vol 5, No 2 (2007)

    African Journals Online (AJOL)

    Gender and Behaviour. ... Gender and Behaviour - Vol 5, No 2 (2007) ... Home Type, Age and Gender on The Antisocial Behaviour of Secondary School Students. ... Gender-Wise Comparison on Emotional Intelligence and Marital Satisfaction.

  1. Afican Health Sciences Vol 10 No 4.pmd

    African Journals Online (AJOL)

    Administrator

    African Health Sciences Vol 10 No 4 December 2010. 353. Effect of ... Key words: Rumex steudelii, Antifertility, Folliculogenesis, Endometrium, uterus, ovary, ovarian follicles, corpus luteum,. Rats. ..... first cycle in intrauterine growth-related and.

  2. Preliminary evaluation of rotational Vol-oxidizer for hot cell operation - 5320

    International Nuclear Information System (INIS)

    Kim, Y.H.; Lee, J.W.; Cho, Y.Z.; Ahn, D.H.; Song, K.C.

    2015-01-01

    KAERI is developing a mechanical head-end process for pyro-processing. As a piece of the processing equipment, a vol-oxidizer that can handle several tens of kg of HM/batch is under development to supply U 3 O 8 powders to an electrolytic reduction (ER) reactor. To operate a vol-oxidizer in a hot cell, the reactor should be optimized by the mechanical design, and the vol-oxidizer should have a high hull recovery rate. In addition, a vol-oxidizer for hot cell demonstrations that handles the spent fuel of high radiation virulence in a limited space should have a small size and not scatter in its outlet. In this paper, we aim at a preliminary evaluation of a rotational vol-oxidizer for hot cell operation. To evaluate the preliminary situation, we produced a theoretical equation of an optimum reactor size, and verification tests were conducted using an acryl vessel and zircaloy-4 tube according to various weights and lengths. In addition, we predicted the terminal velocity of U 3 O 8 using the terminal velocity of SiO 2 , which will determine the optimum air flux, and through an oxidation experiment, we verified the theory form to detect the existence of U 3 O 8 powder in a discharge filter. In addition, hull separation tests were conducted using a reactor and hulls with a 50 kg HM/batch for the recovery rate of the hulls. The results indicate that we obtained an appropriate air flux so as to not cause U 3 O 8 powder dispersion from using a Stokes equation and density ratio equation prior to the demonstration. The optimum flow and experimental results of the hull separation test have been applied for the design of the demonstration oxidizer, and the operation conditions of the oxidizer were produced. (authors)

  3. Joyo progress report, vol. 8

    International Nuclear Information System (INIS)

    1983-01-01

    Following Joyo Reactor Technology Progress Reports (Vol. 1 to Vol. 7), the name was changed to Joyo Progress Report from this volume, and the activities concerning the fast breeder experimental reactor Joyo as a whole are to be reported as quarterly report. In the fast breeder experimental reactor Joyo, the change to the core for irradiation (MK-2) from the core for breeding (MK-1) was carried out since January, 1982, in order to utilize the reactor as an irradiation facility for the development of fuel and materials. The main work was the construction of the core for irradiation by exchanging 290 fuel elements, and the exchange of upper and lower guide pipes for control rods, the reconstruction of the driving mechanism, the installation of standby neutron detector system, the acceptance and inspection of new fuel, and the transfer of spent fuel between pools were carried out. As scheduled, the core for irradiation attained the initial criticality on November 22, and the works of constructing the core were completed on December 23, 1982. Thereafter, the 100 MW performance test was begun. Various experience and valuable data were obtained in the regular inspection and the maintenance and repair works carried out at the same time, regarding the operation and maintenance of the Joyo facilities. (Kako, I.)

  4. Manual on laboratory testing for uranium ore processing

    International Nuclear Information System (INIS)

    1990-01-01

    Laboratory testing of uranium ores is an essential step in the economic evaluation of uranium occurrences and in the development of a project for the production of uranium concentrates. Although these tests represent only a small proportion of the total cost of a project, their proper planning, execution and interpretation are of crucial importance. The main purposes of this manual are to discuss the objectives of metallurgical laboratory ore testing, to show the specific role of these tests in the development of a project, and to provide practical instructions for performing the tests and for interpreting their results. Guidelines on the design of a metallurgical laboratory, on the equipment required to perform the tests and on laboratory safety are also given. This manual is part of a series of Technical Reports on uranium ore processing being prepared by the IAEA's Division of Nuclear Fuel Cycle and Waste Management. A report on the Significance of Mineralogy in the Development of Flowsheets for Processing Uranium Ores (Technical Reports Series No. 196, 1980) and an instruction manual on Methods for the Estimation of Uranium Ore Reserves (No. 255, 1985) have already been published. 17 refs, 40 figs, 17 tabs

  5. Manual on indoor air quality

    International Nuclear Information System (INIS)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues

  6. Manual on indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Diamond, R.C.; Grimsrud, D.T.

    1983-12-01

    This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues.

  7. 21 CFR 868.1030 - Manual algesimeter.

    Science.gov (United States)

    2010-04-01

    ... DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1030 Manual algesimeter. (a) Identification. A manual algesimeter is a mechanical device intended to determine a patient's sensitivity to pain after...

  8. Tanzania Veterinary Journal - Vol 32, No 1 (2017)

    African Journals Online (AJOL)

    Tanzania Veterinary Journal - Vol 32, No 1 (2017) ... factors for porcine cysticercosis transmission and animal welfare in selected villages in Nyasa, Tanzania ... Thoracic radiographic anatomy in sheep · EMAIL FULL TEXT EMAIL FULL TEXT

  9. African Research Review - Vol 5, No 1 (2011)

    African Journals Online (AJOL)

    African Research Review - Vol 5, No 1 (2011) .... Gender and Occupational Preferences among Senior High School Students in Cross River State ... Academic Achievement in Physics · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  10. Software-assisted quantitative analysis of small bowel motility compared to manual measurements

    International Nuclear Information System (INIS)

    Bickelhaupt, S.; Froehlich, J.M.; Cattin, R.; Raible, S.; Bouquet, H.; Bill, U.; Patak, M.A.

    2014-01-01

    Aim: To validate a newly developed software prototype that automatically analyses small bowel motility by comparing it directly with manual measurement. Material and methods: Forty-five patients with clinical indication for small bowel magnetic resonance imaging (MRI) were retrospectively included in this institutional review board-approved study. MRI was performed using a 1.5 T system following a standard MR-enterography protocol. Small bowel motility parameters (contractions-per-minute, luminal diameter, amplitude) were measured three times each in identical segments using the manual and the semiautomatic software-assisted method. The methods were compared for agreement, repeatability, and time needed for each measurement. All parameters were compared between the methods. Results: A total of 91 small-bowel segments were analysed. No significant intra-individual difference (p > 0.05) was found for peristaltic frequencies between the methods (mean: 4.14/min manual; 4.22/min software-assisted). Amplitudes (5.14 mm; 5.57 mm) and mean lumen diameters (17.39 mm; 14.68) differed due to systematic differences in the definition of the bowel wall. Mean duration of single measurement was significantly (p < 0.01) shorter with the software (6.25 min; 1.30 min). The scattering of repeated measurements was significantly (p < 0.05) lower using the software. Conclusion: The software-assisted method accomplished highly reliable, fast and accurate measurement of small bowel motility. Measurement precision and duration differed significantly between the two methods in favour of the software-assisted technique

  11. Eddy current manual: v.1

    International Nuclear Information System (INIS)

    Cecco, V.S.; Van Drunen, G.; Sharp, F.L.

    1983-09-01

    This training and reference manual was assembled to provide those involved in eddy current testing with both the fundamental principles of the technique as well as the knowledge to deal with often complicated test results. A non-rigorous approach is used to simplify complex physical phenomena. Emphasis is placed on proper choice of test frequency and signal interpretation. Defect detection and diagnosis receive particular attention. Design and construction of probes are covered extensively since probes play a key role in eddy current testing. The advantages and limitations of various probe types are discussed. Electromagnetic theory, instrumentation, test methods and signal analysis are covered. Simplified derivations of probe response to test parameters are presented to develop a basic understanding of eddy current behaviour. Eddy current signals are presented on impedance plane diagrams throughout the manual since this is the most common display on modern, general purpose instruments. The use of Σphase lagΣ in signal analysis is covered in detail. To supplement theory, practical examples are presented to develop proficiency in performing inspections, and to illustrate how basic principles are applied to diagnose real signals

  12. Methodes de calcul des forces aerodynamiques pour les etudes des interactions aeroservoelastiques

    Science.gov (United States)

    Biskri, Djallel Eddine

    L'aeroservoelasticite est un domaine ou interagissent la structure flexible d'un avion, l'aerodynamique et la commande de vol. De son cote, la commande du vol considere l'avion comme une structure rigide et etudie l'influence du systeme de commande sur la dynamique de vol. Dans cette these, nous avons code trois nouvelles methodes d'approximation de forces aerodynamiques: Moindres carres corriges, Etat minimal corrige et Etats combines. Dans les deux premieres methodes, les erreurs d'approximation entre les forces aerodynamiques approximees par les methodes classiques et celles obtenues par les nouvelles methodes ont les memes formes analytiques que celles des forces aerodynamiques calculees par LS ou MS. Quant a la troisieme methode, celle-ci combine les formulations des forces approximees avec les methodes standards LS et MS. Les vitesses et frequences de battement et les temps d'executions calcules par les nouvelles methodes versus ceux calcules par les methodes classiques ont ete analyses.

  13. 21 CFR 868.5915 - Manual emergency ventilator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual emergency ventilator. 868.5915 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5915 Manual emergency ventilator. (a) Identification. A manual emergency ventilator is a device, usually incorporating a bag and valve, intended to...

  14. Dental Chairside Technique. Student's Manual.

    Science.gov (United States)

    Apfel, Maura; Weaver, Trudy Karlene

    This manual is part of a series dealing with skills and information needed by students in dental assisting. The individualized student materials are suitable for classroom, laboratory, or cooperative training programs. This student manual contains four units covering the following topics: local anesthesia; dental office emergencies; oral hygiene;…

  15. Nuclear material operations manual

    International Nuclear Information System (INIS)

    Tyler, R.P.

    1981-02-01

    This manual provides a concise and comprehensive documentation of the operating procedures currently practiced at Sandia National Laboratories with regard to the management, control, and accountability of nuclear materials. The manual is divided into chapters which are devoted to the separate functions performed in nuclear material operations-management, control, accountability, and safeguards, and the final two chapters comprise a document which is also issued separately to provide a summary of the information and operating procedures relevant to custodians and users of radioactive and nuclear materials. The manual also contains samples of the forms utilized in carrying out nuclear material activities. To enhance the clarity of presentation, operating procedures are presented in the form of playscripts in which the responsible organizations and necessary actions are clearly delineated in a chronological fashion from the initiation of a transaction to its completion

  16. Nuclear material operations manuals

    International Nuclear Information System (INIS)

    Tyler, R.P.

    1979-06-01

    This manual is intended to provide a concise and comprehensive documentation of the operating procedures currently practiced at Sandia Laboratories with regard to the management, control, and accountability of radioactive and nuclear materials. The manual is divided into chapters which are devoted to the separate functions performed in nuclear material operations-management, control, accountability, and safeguards, and the final two chapters comprise a document which is also issued separately to provide a summary of the information and operating procedures relevant to custodians and users of radioactive and nuclear materials. The manual also contains samples of the forms utilized in carrying out nuclear material activities. To enhance the clarity of presentation, operating procedures are presented in the form of playscripts in which the responsible organizations and necessary actions are clearly delineated in a chronological fashion from the initiation of a transaction to its completion

  17. GLOBAL JOURNAL OF SOCIAL SCIENCES VOL 8, NO

    African Journals Online (AJOL)

    Ada

    GLOBAL JOURNAL OF SOCIAL SCIENCES VOL 8, NO. ... media. From the over fifty tertiary institutions in the country graduates are churned .... few were collected at the contact addresses, ... acquisition is paramount for successful job hunting.

  18. Performance of automated and manual coding systems for occupational data: a case study of historical records.

    Science.gov (United States)

    Patel, Mehul D; Rose, Kathryn M; Owens, Cindy R; Bang, Heejung; Kaufman, Jay S

    2012-03-01

    Occupational data are a common source of workplace exposure and socioeconomic information in epidemiologic research. We compared the performance of two occupation coding methods, an automated software and a manual coder, using occupation and industry titles from U.S. historical records. We collected parental occupational data from 1920-40s birth certificates, Census records, and city directories on 3,135 deceased individuals in the Atherosclerosis Risk in Communities (ARIC) study. Unique occupation-industry narratives were assigned codes by a manual coder and the Standardized Occupation and Industry Coding software program. We calculated agreement between coding methods of classification into major Census occupational groups. Automated coding software assigned codes to 71% of occupations and 76% of industries. Of this subset coded by software, 73% of occupation codes and 69% of industry codes matched between automated and manual coding. For major occupational groups, agreement improved to 89% (kappa = 0.86). Automated occupational coding is a cost-efficient alternative to manual coding. However, some manual coding is required to code incomplete information. We found substantial variability between coders in the assignment of occupations although not as large for major groups.

  19. AFRREV STECH, Vol. 3(1) February, 2014

    African Journals Online (AJOL)

    Toshiba

    Indexed African Journals Online: www.ajol.info. AFRREV STECH. An International Journal of Science and Technology. Bahir Dar, Ethiopia. Vol. 3 (1), S/No 6, February, 2014: 1-11. ISSN 2225-8612 (Print) ISSN 2227-5444 (Online). EFFECTS OF DEFORESTATION ON NATURAL. BIO-DIVERSITY IN DELTA NORTH ...

  20. Geothermal reservoir assessment manual; 1984-1992 nendo chinetsu choryusou hyoka shuhou manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    A geothermal reservoir assessment manual was prepared for the promotion of the development of geothermal power generation, based on the results of the 'geothermal reservoir assessment technique development project' implemented during the fiscal 1984-1992 period and on the results of surveys conducted in Japan and abroad. Of the geothermal systems generally classified into the steam dominant type and the hot water dominant type, encounters with the steam dominant type are but seldom reported. This manual therefore covers the hot water dominant type only. In addition to the explanation of the basic concept and the outline of geothermal reservoirs, the manual carries data necessary for reservoir assessment; geological and geophysical data analyses; geochemistry in reservoir assessment; data of underground logging and of fuming; conceptual models; simulators and models for reservoir simulation; natural-state simulation, history-matching simulation, and reservoir behavior predicting simulation; case history (modeling of a geothermal reservoir prior to exploitation), references, and so forth. (NEDO)

  1. Geothermal reservoir assessment manual; 1984-1992 nendo chinetsu choryusou hyoka shuhou manual

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-02-01

    A geothermal reservoir assessment manual was prepared for the promotion of the development of geothermal power generation, based on the results of the 'geothermal reservoir assessment technique development project' implemented during the fiscal 1984-1992 period and on the results of surveys conducted in Japan and abroad. Of the geothermal systems generally classified into the steam dominant type and the hot water dominant type, encounters with the steam dominant type are but seldom reported. This manual therefore covers the hot water dominant type only. In addition to the explanation of the basic concept and the outline of geothermal reservoirs, the manual carries data necessary for reservoir assessment; geological and geophysical data analyses; geochemistry in reservoir assessment; data of underground logging and of fuming; conceptual models; simulators and models for reservoir simulation; natural-state simulation, history-matching simulation, and reservoir behavior predicting simulation; case history (modeling of a geothermal reservoir prior to exploitation), references, and so forth. (NEDO)

  2. Light-water-reactor hydrogen manual

    International Nuclear Information System (INIS)

    Camp, A.L.; Cummings, J.C.; Sherman, M.P.; Kupiec, C.F.; Healy, R.J.; Caplan, J.S.; Sandhop, J.R.; Saunders, J.H.

    1983-06-01

    A manual concerning the behavior of hydrogen in light water reactors has been prepared. Both normal operations and accident situations are addressed. Topics considered include hydrogen generation, transport and mixing, detection, and combustion, and mitigation. Basic physical and chemical phenomena are described, and plant-specific examples are provided where appropriate. A wide variety of readers, including operators, designers, and NRC staff, will find parts of this manual useful. Different sections are written at different levels, according to the most likely audience. The manual is not intended to provide specific plant procedures, but rather, to provide general guidance that may assist in the development of such procedures

  3. 21 CFR 872.6855 - Manual toothbrush.

    Science.gov (United States)

    2010-04-01

    ... remove adherent plaque and food debris from the teeth to reduce tooth decay. (b) Classification. Class I... DEVICES DENTAL DEVICES Miscellaneous Devices § 872.6855 Manual toothbrush. (a) Identification. A manual...

  4. African Health Sciences - Vol 15, No 4 (2015)

    African Journals Online (AJOL)

    African Health Sciences. ... African Health Sciences - Vol 15, No 4 (2015) .... H Madubedube, Andre P Kengne, Rajiv T Erasmus, Tahir S Pillay, Tandi E ... on lung function and cardiorespiratory fitness in both cigarette and hookah smokers.

  5. 14 CFR 125.75 - Airplane flight manual.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Airplane flight manual. 125.75 Section 125... OPERATIONS: AIRPLANES HAVING A SEATING CAPACITY OF 20 OR MORE PASSENGERS OR A MAXIMUM PAYLOAD CAPACITY OF 6... Airplane flight manual. (a) Each certificate holder shall keep a current approved Airplane Flight Manual or...

  6. Intra- and interobserver variability of MRI-based volume measurements of the hippocampus and amygdala using the manual ray-tracing method

    International Nuclear Information System (INIS)

    Achten, E.; Deblaere, K.; Damme, F. van; Kunnen, M.; Wagter, C. de; Boon, P.; Reuck, J. de

    1998-01-01

    We studied the intra- and interobserver variability of volume measurments of the hippocampus (HC) and the amygdala as applied to the detection of HC atrophy in patients with complex partial seizures (CPE), measuring the volumes of the HC and amygdala of 11 normal volunteers and 12 patients with presumed CPE, using the manual ray-tracing method. Two independent observers performed these measurements twice each using home-made software. The intra- and interobserver variability of the absolute volumes and of the normalised left-to-right volume differences (δV) between the HC (δV HC ), the amygdala (δV A ) and the sum of both (δV HCA) were assessed. In our mainly right-handed normals, the right HC and amygdala were on average 0.05 and 0.03 ml larger respectively than on the left. The interobserver variability for volume measurements in normal subjects was 1.80 ml for the HC and 0.82 ml for the amygdala, the intraobserver variability roughly one third of these values. The interobserver variability coefficient in normals was 3.6 % for δV HCA , 4.7 % for δV HC and 7.3 % for δV A . The intraobserver variability coefficient was 3.4 % for δV HCA , 4.2 % for δV HC amd 5.6 % for δV A . The variability in patients was the same for volume differences less than 5 % either side of the interval for normality, but was higher when large volume differences were encountered, is probably due to the lack of thresholding and/or normalisation. Cutoff values for lateralisation with the δV were defined. No intra- or interobserver lateralisation differences were encountered with δV HCA and δV HC . From these observations we conclude that the manual ray-tracing method is a robust method for lateralisation in patients with TLE. Due to its higher variability, this method is less suited to measure absolute volumes. (orig.) (orig.)

  7. Intra- and interobserver variability of MRI-based volume measurements of the hippocampus and amygdala using the manual ray-tracing method

    Energy Technology Data Exchange (ETDEWEB)

    Achten, E.; Deblaere, K.; Damme, F. van; Kunnen, M. [MR Department 1K12, University Hospital Gent (Belgium); Wagter, C. de [Department of Radiotherapy and Nuclear Medicine, University Hospital Gent (Belgium); Boon, P.; Reuck, J. de [Department of Neurology, University Hospital Gent (Belgium)

    1998-09-01

    We studied the intra- and interobserver variability of volume measurments of the hippocampus (HC) and the amygdala as applied to the detection of HC atrophy in patients with complex partial seizures (CPE), measuring the volumes of the HC and amygdala of 11 normal volunteers and 12 patients with presumed CPE, using the manual ray-tracing method. Two independent observers performed these measurements twice each using home-made software. The intra- and interobserver variability of the absolute volumes and of the normalised left-to-right volume differences ({delta}V) between the HC ({delta}V{sub HC}), the amygdala ({delta}V{sub A}) and the sum of both ({delta}V{sub HCA)} were assessed. In our mainly right-handed normals, the right HC and amygdala were on average 0.05 and 0.03 ml larger respectively than on the left. The interobserver variability for volume measurements in normal subjects was 1.80 ml for the HC and 0.82 ml for the amygdala, the intraobserver variability roughly one third of these values. The interobserver variability coefficient in normals was 3.6 % for {delta}V{sub HCA}, 4.7 % for {delta}V{sub HC} and 7.3 % for {delta}V{sub A}. The intraobserver variability coefficient was 3.4 % for {delta}V{sub HCA}, 4.2 % for {delta}V{sub HC} amd 5.6 % for {delta}V{sub A}. The variability in patients was the same for volume differences less than 5 % either side of the interval for normality, but was higher when large volume differences were encountered, is probably due to the lack of thresholding and/or normalisation. Cutoff values for lateralisation with the {delta}V were defined. No intra- or interobserver lateralisation differences were encountered with {delta}V{sub HCA} and {delta}V{sub HC}. From these observations we conclude that the manual ray-tracing method is a robust method for lateralisation in patients with TLE. Due to its higher variability, this method is less suited to measure absolute volumes. (orig.) (orig.) With 2 figs., 7 tabs., 23 refs.

  8. Methode d’Identification des Forces Aerodynamiques Instationnaires sur les Essais en Vol, Validation Experimentale (Method of Mathematical Identification of Unsteady Airloads From Flight Measurements, Experimental Validation)

    Science.gov (United States)

    2000-05-01

    gage en vol de rdponses de jauges de contraintes en responses in maneuver, illustrated by an example manoeuvre, illustrd par un exemple issu de la coming...sous ddrapage, ... , braquages gouvernes,..) la forme: -Les mesures sont directement les rkponses de - minimiser Z = Q(k - Xj tb) 2 jauges de...3, la rdponse - les facteurs de ponddration des mesures, fli ou incidence de l’avion, la rdponse de la jauge plus ou momns subjectifs, sont remplacds

  9. Kinesiology Workbook and Laboratory Manual.

    Science.gov (United States)

    Harris, Ruth W.

    This manual is written for students in anatomy, kinesiology, or introductory biomechanics courses. The book is divided into two sections, a kinesiology workbook and a laboratory manual. The two sections parallel each other in content and format. Each is divided into three corresponding sections: (1) Anatomical bases for movement description; (2)…

  10. Manual therapy with and without vestibular rehabilitation for cervicogenic dizziness: a systematic review

    Directory of Open Access Journals (Sweden)

    Lystad Reidar P

    2011-09-01

    Full Text Available Abstract Background Manual therapy is an intervention commonly advocated in the management of dizziness of a suspected cervical origin. Vestibular rehabilitation exercises have been shown to be effective in the treatment of unilateral peripheral vestibular disorders, and have also been suggested in the literature as an adjunct in the treatment of cervicogenic dizziness. The purpose of this systematic review is to evaluate the evidence for manual therapy, in conjunction with or without vestibular rehabilitation, in the management of cervicogenic dizziness. Methods A comprehensive search was conducted in the databases Scopus, Mantis, CINHAL and the Cochrane Library for terms related to manual therapy, vestibular rehabilitation and cervicogenic dizziness. Included studies were assessed using the Maastricht-Amsterdam criteria. Results A total of fifteen articles reporting findings from thirteen unique investigations, including five randomised controlled trials and eight prospective, non-controlled cohort studies were included in this review. The methodological quality of the included studies was generally poor to moderate. All but one study reported improvement in dizziness following either unimodal or multimodal manual therapy interventions. Some studies reported improvements in postural stability, joint positioning, range of motion, muscle tenderness, neck pain and vertebrobasilar artery blood flow velocity. Discussion Although it has been argued that manual therapy combined with vestibular rehabilitation may be superior in the treatment of cervicogenic dizziness, there are currently no observational and experimental studies demonstrating such effects. A rationale for combining manual therapy and vestibular rehabilitation in the management of cervicogenic dizziness is presented. Conclusion There is moderate evidence to support the use of manual therapy, in particular spinal mobilisation and manipulation, for cervicogenic dizziness. The evidence

  11. Tank waste remediation system process engineering instruction manual

    International Nuclear Information System (INIS)

    ADAMS, M.R.

    1998-01-01

    The purpose of the Tank Waste Remediation System (TWRS) Process Engineering Instruction Manual is to provide guidance and direction to TWRS Process Engineering staff regarding conduct of business. The objective is to establish a disciplined and consistent approach to business such that the work processes within TWRS Process Engineering are safe, high quality, disciplined, efficient, and consistent with Lockheed Martin Hanford Corporation Policies and Procedures. The sections within this manual are of two types: for compliance and for guidance. For compliance sections are intended to be followed per-the-letter until such time as they are formally changed per Section 2.0 of this manual. For guidance sections are intended to be used by the staff for guidance in the conduct of work where technical judgment and discernment are required. The guidance sections shall also be changed per Section 2.0 of this manual. The required header for each manual section is illustrated in Section 2.0, Manual Change Control procedure. It is intended that this manual be used as a training and indoctrination resource for employees of the TWRS Process Engineering organization. The manual shall be required reading for all TWRS Process Engineering staff, matrixed, and subcontracted employees

  12. African Health Sciences - Vol 13, No 2 (2013)

    African Journals Online (AJOL)

    African Health Sciences. ... African Health Sciences - Vol 13, No 2 (2013) ... S Musisi, D Akena, E Nakimuli-Mpungu, C Abbo, J Okello, 205-218 .... Alcohol consumption and cigarette smoking pattern among brothelbased female sex workers in ...

  13. Radiology Aide. Instructor Key [and] Student Manual.

    Science.gov (United States)

    Hartwein, Jon; Dunham, John

    This manual can be used independently by students in secondary health occupations programs or by persons receiving on-the-job training in a radiology department. The manual includes an instructor's key that provides answers to the activity sheets and unit evaluations. The manual consists of the following five units: (1) orientation to radiology;…

  14. Nuclear material operations manual

    International Nuclear Information System (INIS)

    Tyler, R.P.; Gassman, L.D.

    1978-04-01

    This manual is intended to provide a concise and comprehensive documentation of the operating procedures currently practiced at Sandia Laboratories with regard to the management, control, and accountability of radioactive and nuclear materials. The manual is divided into chapters which are devoted to the separate functions performed in nuclear material operations--management, control, accountability, and safeguards, and the final two chapters comprise a document which is also issued separately to provide a summary of the information and operating procedures relevant to custodians and users of radioactive and nuclear materials. The manual also contains samples of the forms utilized in carrying out nuclear material activities. To enhance the clarity of presentation, operating procedures are presented in the form of ''play-scripts'' in which the responsible organizations and necessary actions are clearly delineated in a chronological fashion from the initiation of a transaction to its completion

  15. WAM-E user's manual

    International Nuclear Information System (INIS)

    Rayes, L.G.; Riley, J.E.

    1986-07-01

    The WAM-E series of mainframe computer codes have been developed to efficiently analyze the large binary models (e.g., fault trees) used to represent the logic relationships within and between the systems of a nuclear power plant or other large, multisystem entity. These codes have found wide application in reliability and safety studies of nuclear power plant systems. There are now nine codes in the WAM-E series, with six (WAMBAM/WAMTAP, WAMCUT, WAMCUT-II, WAMFM, WAMMRG, and SPASM) classified as Type A Production codes and the other three (WAMFTP, WAMTOP, and WAMCONV) classified as Research codes. This document serves as a combined User's Guide, Programmer's Manual, and Theory Reference for the codes, with emphasis on the Production codes. To that end, the manual is divided into four parts: Part I, Introduction; Part II, Theory and Numerics; Part III, WAM-E User's Guide; and Part IV, WAMMRG Programmer's Manual

  16. [A workplace intervention aimed at increasing awareness in nursing personnel performing manual handling activities].

    Science.gov (United States)

    Scorpiniti, A; Lorusso, A; L'Abbate, N

    2007-01-01

    Here we describe a workplace intervention aimed at reducing the risk of low back pain in nursing personnel. The intervention we carried out included a specific ergonomic training and an exercise program according to the Feldenkrais Method. After the intervention, we evaluated its effect on the execution of manual handling activities in nurses. We found an increased rate of correct manual handling in the post-intervention period.

  17. Managerial Accounting. Course Administrative Manual.

    Science.gov (United States)

    Central Michigan Univ., Mount Pleasant. Inst. for Personal and Career Development.

    This manual is part of the materials for a college-level programmed course in managerial accounting and intended to aid instructors in helping students to work their way through the self-instructional study guide around which the course is organized. The manual describes the various materials and components used in the self-instructional sequence…

  18. AJESMS Vol 9 2011 October 23 2012 final

    African Journals Online (AJOL)

    Owner

    2011-10-23

    Oct 23, 2011 ... African Journal of Educational Studies in Mathematics and Sciences Vol. ... alveolar re-circulation and gravity orientation are key factors in determining the ..... Comp. Biomed. Res. 3, pp 675-689. Pich, J. (1972). Theory of ...

  19. African Research Review - Vol 4, No 4 (2010)

    African Journals Online (AJOL)

    African Research Review - Vol 4, No 4 (2010) .... Educational Policy and Technological Development in Africa: An X-Ray of Problems and Solutions in the .... Tradition and Art Appreciation: A Boost to Cultural Tourism in Nigeria · EMAIL FREE ...

  20. NV/YMP RADIOLOGICAL CONTROL MANUAL

    Energy Technology Data Exchange (ETDEWEB)

    U.S. DEPARTMENT OF ENERGY, NATIONAL NUCLEAR SECURITY ADMINISTRATION NEVADA SITE OFFICE; BECHTEL NEVADA

    2004-11-01

    This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) and the Yucca Mountain Office of Repository Development (YMORD). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations Part 835 (10 CFR 835), Occupational Radiation Protection. Programs covered by this manual are located at the Nevada Test Site (NTS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Pleasanton, California; and at Andrews Air Force Base, Maryland. In addition, field work by NNSA/NSO at other locations is also covered by this manual.

  1. NV/YMP RADIOLOGICAL CONTROL MANUAL

    International Nuclear Information System (INIS)

    2004-01-01

    This manual contains the radiological control requirements to be used for all radiological activities conducted by programs under the purview of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) and the Yucca Mountain Office of Repository Development (YMORD). Compliance with these requirements will ensure compliance with Title 10 Code of Federal Regulations Part 835 (10 CFR 835), Occupational Radiation Protection. Programs covered by this manual are located at the Nevada Test Site (NTS); Nellis Air Force Base and North Las Vegas, Nevada; Santa Barbara and Pleasanton, California; and at Andrews Air Force Base, Maryland. In addition, field work by NNSA/NSO at other locations is also covered by this manual

  2. Radiological Control Manual. Revision 0, January 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    This manual has been prepared by Lawrence Berkeley Laboratory to provide guidance for site-specific additions, supplements, and clarifications to the DOE Radiological Control Manual. The guidance provided in this manual is based on the requirements given in Title 10 Code of Federal Regulations Part 835, Radiation Protection for Occupational Workers, DOE Order 5480.11, Radiation Protection for Occupational Workers, and the DOE Radiological Control Manual. The topics covered are (1) excellence in radiological control, (2) radiological standards, (3) conduct of radiological work, (4) radioactive materials, (5) radiological health support operations, (6) training and qualification, and (7) radiological records.

  3. A comparison of four gravimetric fine particle sampling methods.

    Science.gov (United States)

    Yanosky, J D; MacIntosh, D L

    2001-06-01

    A study was conducted to compare four gravimetric methods of measuring fine particle (PM2.5) concentrations in air: the BGI, Inc. PQ200 Federal Reference Method PM2.5 (FRM) sampler; the Harvard-Marple Impactor (HI); the BGI, Inc. GK2.05 KTL Respirable/Thoracic Cyclone (KTL); and the AirMetrics MiniVol (MiniVol). Pairs of FRM, HI, and KTL samplers and one MiniVol sampler were collocated and 24-hr integrated PM2.5 samples were collected on 21 days from January 6 through April 9, 2000. The mean and standard deviation of PM2.5 levels from the FRM samplers were 13.6 and 6.8 microg/m3, respectively. Significant systematic bias was found between mean concentrations from the FRM and the MiniVol (1.14 microg/m3, p = 0.0007), the HI and the MiniVol (0.85 microg/m3, p = 0.0048), and the KTL and the MiniVol (1.23 microg/m3, p = 0.0078) according to paired t test analyses. Linear regression on all pairwise combinations of the sampler types was used to evaluate measurements made by the samplers. None of the regression intercepts was significantly different from 0, and only two of the regression slopes were significantly different from 1, that for the FRM and the MiniVol [beta1 = 0.91, 95% CI (0.83-0.99)] and that for the KTL and the MiniVol [beta1 = 0.88, 95% CI (0.78-0.98)]. Regression R2 terms were 0.96 or greater between all pairs of samplers, and regression root mean square error terms (RMSE) were 1.65 microg/m3 or less. These results suggest that the MiniVol will underestimate measurements made by the FRM, the HI, and the KTL by an amount proportional to PM2.5 concentration. Nonetheless, these results indicate that all of the sampler types are comparable if approximately 10% variation on the mean levels and on individual measurement levels is considered acceptable and the actual concentration is within the range of this study (5-35 microg/m3).

  4. Determining the energy performance of manually controlled solar shades: A stochastic model based co-simulation analysis

    International Nuclear Information System (INIS)

    Yao, Jian

    2014-01-01

    Highlights: • Driving factor for adjustment of manually controlled solar shades was determined. • A stochastic model for manual solar shades was constructed using Markov method. • Co-simulation with Energyplus was carried out in BCVTB. • External shading even manually controlled should be used prior to LOW-E windows. • Previous studies on manual solar shades may overestimate energy savings. - Abstract: Solar shading devices play a significant role in reducing building energy consumption and maintaining a comfortable indoor condition. In this paper, a typical office building with internal roller shades in hot summer and cold winter zone was selected to determine the driving factor of control behavior of manual solar shades. Solar radiation was determined as the major factor in driving solar shading adjustment based on field measurements and logit analysis and then a stochastic model for manually adjusted solar shades was constructed by using Markov method. This model was used in BCVTB for further co-simulation with Energyplus to determine the impact of the control behavior of solar shades on energy performance. The results show that manually adjusted solar shades, whatever located inside or outside, have a relatively high energy saving performance than clear-pane windows while only external shades perform better than regularly used LOW-E windows. Simulation also indicates that using an ideal assumption of solar shade adjustment as most studies do in building simulation may lead to an overestimation of energy saving by about 16–30%. There is a need to improve occupants’ actions on shades to more effectively respond to outdoor conditions in order to lower energy consumption, and this improvement can be easily achieved by using simple strategies as a guide to control manual solar shades

  5. Assessing the Agreement Between Eo-Based Semi-Automated Landslide Maps with Fuzzy Manual Landslide Delineation

    Science.gov (United States)

    Albrecht, F.; Hölbling, D.; Friedl, B.

    2017-09-01

    Landslide mapping benefits from the ever increasing availability of Earth Observation (EO) data resulting from programmes like the Copernicus Sentinel missions and improved infrastructure for data access. However, there arises the need for improved automated landslide information extraction processes from EO data while the dominant method is still manual delineation. Object-based image analysis (OBIA) provides the means for the fast and efficient extraction of landslide information. To prove its quality, automated results are often compared to manually delineated landslide maps. Although there is awareness of the uncertainties inherent in manual delineations, there is a lack of understanding how they affect the levels of agreement in a direct comparison of OBIA-derived landslide maps and manually derived landslide maps. In order to provide an improved reference, we present a fuzzy approach for the manual delineation of landslides on optical satellite images, thereby making the inherent uncertainties of the delineation explicit. The fuzzy manual delineation and the OBIA classification are compared by accuracy metrics accepted in the remote sensing community. We have tested this approach for high resolution (HR) satellite images of three large landslides in Austria and Italy. We were able to show that the deviation of the OBIA result from the manual delineation can mainly be attributed to the uncertainty inherent in the manual delineation process, a relevant issue for the design of validation processes for OBIA-derived landslide maps.

  6. Physics at LEP2. Vol. 2

    International Nuclear Information System (INIS)

    Altarelli, G.; Sjoestrand, T.; Zwirner, F.

    1995-01-01

    This is final report of the Workshop on Physics at LEP2, held at CERN during 1995. The first part of vol. 1 is devoted to aspects of machine physics of particular relevance to experiments, including the energy, luminosity and interaction regions, as well as the measurement of beam energy. The second part of vol. 1 is a relatively concise, but fairly complete, handbook on the physics of e + e - annihilation above the WW threshold and up to √s∼200 GeV. It contains discussions on WW cross-sections and distributions, W mass determination, Standard Model processes, QCD and gamma-gamma physics, as well as aspects of discovery physics, such as Higgs, new particle searches, triple gauge boson couplings and Z'. The second volume contains a review of the existing Monte Carlo generators for LEP2 physics. These include generators for WW physics, QCD and gamma-gamma processes, Bhabha scattering and discovery physics. A special effort was made to co-ordinate the different parts, with a view to achieving a systematic and balanced review of the subject, rather than just publishing a collection of separate contributions. (orig.)

  7. Physics at LEP2. Vol. 1

    International Nuclear Information System (INIS)

    Altarelli, G.; Sjoestrand, T.; Zwirner, F.

    1996-01-01

    This is the final report of the Workshop on Physics at LEP2, held at CERN during 1995. The first part of vol. 1 is devoted to aspects of machine physics of particular relevance to experiments, including the energy, luminosity and interaction regions, as well as the measurement of beam energy. The second part of vol. 1 is a relatively concise, but fairly complete, handbook on the physics of e + e - annihilation above the WW threshold and up to √s∼200 GeV. It contains discussions on WW cross-sections and distributions, W mass determination, Standard Model processes, QCD and gamma-gamma physics, as well as aspects of discovery physics, such as Higgs, new particle searches, triple gauge boson couplings and Z'. The second volume contains a review of the existing Monte Carlo generators for LEP2 physics. These include generators for WW physics, QCD and gamma-gamma processes, Bhabha scattering and discovery physics. A special effort was made to co-ordinate the different parts, with a view to achieving a systematic and balanced review of the subject, rather than just publishing a collection of separate contributions. (orig.)

  8. Physics at LEP2. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Altarelli, G [ed.; Sjoestrand, T [ed.; Zwirner, F [ed.

    1995-02-19

    This is final report of the Workshop on Physics at LEP2, held at CERN during 1995. The first part of vol. 1 is devoted to aspects of machine physics of particular relevance to experiments, including the energy, luminosity and interaction regions, as well as the measurement of beam energy. The second part of vol. 1 is a relatively concise, but fairly complete, handbook on the physics of e{sup +}e{sup -} annihilation above the WW threshold and up to {radical}s{approx}200 GeV. It contains discussions on WW cross-sections and distributions, W mass determination, Standard Model processes, QCD and gamma-gamma physics, as well as aspects of discovery physics, such as Higgs, new particle searches, triple gauge boson couplings and Z`. The second volume contains a review of the existing Monte Carlo generators for LEP2 physics. These include generators for WW physics, QCD and gamma-gamma processes, Bhabha scattering and discovery physics. A special effort was made to co-ordinate the different parts, with a view to achieving a systematic and balanced review of the subject, rather than just publishing a collection of separate contributions. (orig.).

  9. Users Manual for the FEHMN application

    International Nuclear Information System (INIS)

    Zyvoloski, G.A.; Robinson, B.A.; Dash, Z.V.; Trease, L.L.

    1996-01-01

    The user's manual documents the use of the Yucca Mountain Site Characterization Projects Finite element heat and mass transfer code (FEHMN) application. The manual covers: Program considerations, data files, input data, output, system interface, and examples

  10. Manual therapy for plantar heel pain.

    Science.gov (United States)

    Pollack, Yosefa; Shashua, Anat; Kalichman, Leonid

    2018-03-01

    Manual therapy employed in the treatment of plantar heel pain includes joint or soft tissue mobilizations. Efficacy of these methods is still under debate. To determine whether manual therapy, consisting of deep massage, myofascial release or joint mobilization is effective in treating plantar heel pain. A critical review of all available studies with an emphasis on randomized controlled trials (RCTs) was performed. PubMed, PEDro, and Google Scholar databases were searched for keywords relating to plantar heel pain, joint, and soft tissue mobilizations. There were no search limitations or language restrictions. The reference lists of all retrieved articles were searched. The PEDro score was used to assess the quality of the reviewed papers. A total of six relevant RCTs were found: two examined the effectiveness of joint mobilization on plantar heel pain and four the effectiveness of soft tissue techniques. Five studies showed a positive short-term effect after manual therapy treatment, mostly soft tissue mobilizations, with or without stretching exercises for patients with plantar heel pain, compared to other treatments. One study observed that adding joint mobilization to the treatment of plantar heel pain was not effective. The quality of all studies was moderate to high. According to reviewed moderate and high-quality RCTs, soft tissue mobilization is an effective modality for treating plantar heel pain. Outcomes of joint mobilizations are controversial. Further studies are needed to evaluate the short and long-term effect of different soft tissue mobilization techniques. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Manual hyperinflation in airway clearance in pediatric patients: a systematic review

    Science.gov (United States)

    de Godoy, Vanessa Cristina Waetge Pires; Zanetti, Nathalia Mendonça; Johnston, Cíntia

    2013-01-01

    Objective To perform an assessment of the available literature on manual hyperinflation as a respiratory physical therapy technique used in pediatric patients, with the main outcome of achieving airway clearance. Methods We reviewed articles included in the Lilacs (Latin American and Caribbean Literature on Health Sciences/Literatura Latino Americana e do Caribe em Ciências da Saúde), Cochrane Library, Medline (via Virtual Health Library and PubMed), SciELO (Scientific Electronic Library), and PEDro (Physiotherapy Evidence Database) databases from 2002 to 2013 using the following search terms: "physiotherapy (techniques)", "respiratory therapy", "intensive care", and "airway clearance". The selected studies were classified according to the level of evidence and grades of recommendation (method of the Oxford Centre for Evidence-Based Medicine) by two examiners, while a third examiner repeated the search and analysis and checked the classification of the articles. Results Three articles were included for analysis, comprising 250 children (aged 0 to 16 years). The main diagnoses were acute respiratory failure, recovery following heart congenital disease and upper abdominal surgery, bone marrow transplantation, asthma, tracheal reconstruction, brain injury, airway injury, and heterogeneous lung diseases. The studies were classified as having a level of evidence 2C and grade of recommendation C. Conclusions Manual hyperinflation appeared useful for airway clearance in the investigated population, although the evidence available in the literature remains insufficient. Therefore, controlled randomized studies are needed to establish the safety and efficacy of manual hyperinflation in pediatric patients. However, manual hyperinflation must be performed by trained physical therapists only. PMID:24213091

  12. Local Intraarterial Thrombolysis: In Vitro Comparison Between Automatic and Manual Pulse-Spray Infusion

    International Nuclear Information System (INIS)

    Froelich, Jens J.; Freymann, Christina; Hoppe, Martin; Thiel, Thomas; Wagner, H. Joachim; Barth, Klemens H.; Klose, Klaus J.

    1996-01-01

    Purpose: Manual and automatic pulse-spray infusion techniques are compared in vitro to evaluate the efficacy of thrombolysis and the distribution of urokinase and saline solution within thrombus using a pulse-spray catheter. Methods: A pulse-spray catheter was introduced into a human thrombus within a stenotic flow model. Automatic and manual pulsed infusion of urokinase and automatic pulsed infusion of saline solution were compared. To quantify the efficacy of thrombolysis, pressure gradients were recorded proximal and distal to the thrombus and during the course of infusion. Distribution of infused urokinase was assessed radiographically. Results: The fastest and most homogeneous dissolution of the thrombus was achieved with automatic pulsed infusion of urokinase, shown by decreasing transthrombotic pressure gradients (p < 0.001, Wilcoxon, matched pairs). Manual pulsed infusion of urokinase or saline solution resulted in inhomogeneous thrombus dissolution and delayed thrombolysis. Conclusion: Application of automatic pulse-spray injectors seems beneficial for more effective and homogeneous intraarterial pulse-spray thrombolysis when compared with conventional manual pulsed technique

  13. U.S. Department of Energy Vehicle Technologies Program: Battery Test Manual For Plug-In Hybrid Electric Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Christophersen, Jon P. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-09-01

    This battery test procedure manual was prepared for the United States Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Office. It is based on technical targets for commercial viability established for energy storage development projects aimed at meeting system level DOE goals for Plug-in Hybrid Electric Vehicles (PHEV). The specific procedures defined in this manual support the performance and life characterization of advanced battery devices under development for PHEV’s. However, it does share some methods described in the previously published battery test manual for power-assist hybrid electric vehicles. Due to the complexity of some of the procedures and supporting analysis, future revisions including some modifications and clarifications of these procedures are expected. As in previous battery and capacitor test manuals, this version of the manual defines testing methods for full-size battery systems, along with provisions for scaling these tests for modules, cells or other subscale level devices. The DOE-United States Advanced Battery Consortium (USABC), Technical Advisory Committee (TAC) supported the development of the manual. Technical Team points of contact responsible for its development and revision are Renata M. Arsenault of Ford Motor Company and Jon P. Christophersen of the Idaho National Laboratory. The development of this manual was funded by the Unites States Department of Energy, Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Office. Technical direction from DOE was provided by David Howell, Energy Storage R&D Manager and Hybrid Electric Systems Team Leader. Comments and questions regarding the manual should be directed to Jon P. Christophersen at the Idaho National Laboratory (jon.christophersen@inl.gov).

  14. Afican Health Sciences Vol 9 No 2.pmd

    African Journals Online (AJOL)

    Administrator

    African Health Sciences Vol 9 No 2 June 2009 ... Background:The under five mortality rate (U5MR) is measure of wellbeing and decreasing the U5MR by two .... under three scenarios 1-3. ... Negative indicates increase in childhood mortalities.

  15. User manual for Blossom statistical package for R

    Science.gov (United States)

    Talbert, Marian; Cade, Brian S.

    2005-01-01

    Blossom is an R package with functions for making statistical comparisons with distance-function based permutation tests developed by P.W. Mielke, Jr. and colleagues at Colorado State University (Mielke and Berry, 2001) and for testing parameters estimated in linear models with permutation procedures developed by B. S. Cade and colleagues at the Fort Collins Science Center, U.S. Geological Survey. This manual is intended to provide identical documentation of the statistical methods and interpretations as the manual by Cade and Richards (2005) does for the original Fortran program, but with changes made with respect to command inputs and outputs to reflect the new implementation as a package for R (R Development Core Team, 2012). This implementation in R has allowed for numerous improvements not supported by the Cade and Richards (2005) Fortran implementation, including use of categorical predictor variables in most routines.

  16. Development of an environmental safety case guidance manual

    International Nuclear Information System (INIS)

    Wellstead, Matthew John

    2014-01-01

    NDA RWMD is currently considering the scope, purpose and structure of a safety case manual that covers the development of nuclear operational, transport and environmental safety cases for a geological disposal facility in the United Kingdom. This paper considers the Environmental Safety Case (ESC) input into such a manual (herein referred to as the 'ESC Manual'), looking at the drivers and benefits that a guidance manual in this area may provide. (authors)

  17. An Experimental Study of Force Involved in Manual Rebar Bending Process

    Science.gov (United States)

    Deepu, Sasi; Vishnu, Rajendran S.; Harish, Mohan T.; Bhavani, Rao R.

    2018-02-01

    The work presents an experimental method of understanding the force applied during a manual rebar bending process. The study tracks the force with the variation of the angle of bend and the elapsed time from the start to the end of a complete manual rebar bending process. A sample of expert rebar bending labourers are used for conducting the experiment and the data processed to set a performance standard. If a simulator based rebar bending training can be provided for a novice, this standard can be used as a matrix to define how close a novice rebar bender is closing to the expertise.

  18. Manual for JSSL (JAERI Scientific Subroutine Library)

    International Nuclear Information System (INIS)

    Fujimura, Toichiro; Tsutsui, Tsuneo

    1991-09-01

    JSSL (JAERI Scientific Subroutine Library) is a library of scientific subroutines developed or modified in JAERI. They are classified into sixteen fields (Special Functions, Linear Problems, Eigenvalue and Eigenvector Problems, Non Linear Problems, Mathematical Programming, Extreme Value Problems, Transformations, Functional Approximation Methods, Numerical Differential and Integral Methods, Numerical Differential and Integral Equations, Statistical Functions, Physical Problems, I/O Routines, Plotter Routines, Computer System Functions and Others). This report is the user manual for the revised version of JSSL which involves evaluated subroutines selected from the previous compilation of JSSL, applied in almost all the fields. (author)

  19. Site security personnel training manual

    International Nuclear Information System (INIS)

    1978-10-01

    As required by 10 CFR Part 73, this training manual provides guidance to assist licensees in the development of security personnel training and qualifications programs. The information contained in the manual typifies the level and scope of training for personnel assigned to perform security related tasks and job duties associated with the protection of nuclear fuel cycle facilities and nuclear power reactors

  20. Radiation protection manual

    International Nuclear Information System (INIS)

    Spang, A.

    1983-01-01

    According to the Radiation Protection Ordinance, radiation protection experts directing or supervising the handling of radioactive materials must have expert knowledge. The concept of expert knowledge has been clearly defined by the Fachverband e.V. in a catalogue of instruction goals. The manual follows the principles of this catalogue; it presents the expert knowledge required in a total of 15 subject groups. There is an index which helps the reader to find his specific subject group and the knowledge required of him in this subject group. However, the manual gives only an outline of the subject matter in many instances and should therefore not be regarded as a textbook in the proper sense. (orig./HP) [de

  1. Gravel Roads: Maintenance and Design Manual

    Science.gov (United States)

    This manual was developed with a major emphasis on the maintenance of gravel roads, including some basic design elements. The purpose of the manual is to provide clear and helpful information for doing a better job of maintaining gravel roads.

  2. Radar and ARPA manual

    CERN Document Server

    Bole, A G

    2013-01-01

    Radar and ARPA Manual focuses on the theoretical and practical aspects of electronic navigation. The manual first discusses basic radar principles, including principles of range and bearing measurements and picture orientation and presentation. The text then looks at the operational principles of radar systems. Function of units; aerial, receiver, and display principles; transmitter principles; and sitting of units on board ships are discussed. The book also describes target detection, Automatic Radar Plotting Aids (ARPA), and operational controls of radar systems, and then discusses radar plo

  3. MATADOR (Methods for the Analysis of Transport And Deposition Of Radionuclides) code description and User's Manual

    International Nuclear Information System (INIS)

    Avci, H.I.; Raghuram, S.; Baybutt, P.

    1985-04-01

    A new computer code called MATADOR (Methods for the Analysis of Transport And Deposition Of Radionuclides) has been developed to replace the CORRAL-2 computer code which was written for the Reactor Safety Study (WASH-1400). This report is a User's Manual for MATADOR. MATADOR is intended for use in system risk studies to analyze radionuclide transport and deposition in reactor containments. The principal output of the code is information on the timing and magnitude of radionuclide releases to the environment as a result of severely degraded core accidents. MATADOR considers the transport of radionuclides through the containment and their removal by natural deposition and by engineered safety systems such as sprays. It is capable of analyzing the behavior of radionuclides existing either as vapors or aerosols in the containment. The code requires input data on the source terms into the containment, the geometry of the containment, and thermal-hydraulic conditions in the containment

  4. HASL procedures manual

    International Nuclear Information System (INIS)

    Harley, J.H.

    1977-08-01

    Additions and corrections to the following sections of the HASL Procedures Manual are provided: General, Sampling, Field Measurements; General Analytical Chemistry, Chemical Procedures, Data Section, and Specifications

  5. Southern African Business Review - Vol 21, No 1 (2017)

    African Journals Online (AJOL)

    Southern African Business Review - Vol 21, No 1 (2017) ... Pre-packaged applications in business reorganisations: International principles · EMAIL ... Microcredit supply under Islamic Banking in Khartoum State, Sudan · EMAIL FREE FULL ...

  6. Foot Pedals for Spacecraft Manual Control

    Science.gov (United States)

    Love, Stanley G.; Morin, Lee M.; McCabe, Mary

    2010-01-01

    Fifty years ago, NASA decided that the cockpit controls in spacecraft should be like the ones in airplanes. But controls based on the stick and rudder may not be best way to manually control a vehicle in space. A different method is based on submersible vehicles controlled with foot pedals. A new pilot can learn the sub's control scheme in minutes and drive it hands-free. We are building a pair of foot pedals for spacecraft control, and will test them in a spacecraft flight simulator.

  7. Journal of Applied Sciences and Environmental Management - Vol ...

    African Journals Online (AJOL)

    Journal of Applied Sciences and Environmental Management. ... AFRICAN JOURNALS ONLINE (AJOL) · Journals · Advanced Search · USING ... Journal of Applied Sciences and Environmental Management - Vol 22, No 5 (2018) .... Growth Performance of Five Bean (Phaseolus spp) Varieties as Influenced by Organic ...

  8. Integrated Fuel-Coolant Interaction (IFCI 7.0) Code User's Manual

    Energy Technology Data Exchange (ETDEWEB)

    Young, Michael F.

    1999-05-01

    The integrated fuel-coolant interaction (IFCI) computer code is being developed at Sandia National Laboratories to investigate the fuel-coolant interaction (FCI) problem at large scale using a two-dimensional, three-field hydrodynamic framework and physically based models. IFCI will be capable of treating all major FCI processes in an integrated manner. This document is a description of IFCI 7.0. The user's manual describes the hydrodynamic method and physical models used in IFCI 7.0. Appendix A is an input manual provided for the creation of working decks.

  9. 21 CFR 892.5650 - Manual radionuclide applicator system.

    Science.gov (United States)

    2010-04-01

    ... system. (a) Identification. A manual radionuclide applicator system is a manually operated device... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual radionuclide applicator system. 892.5650.... This generic type of device may include patient and equipment supports, component parts, treatment...

  10. AJESMS_ Vol 8 2010 August 15 2011

    African Journals Online (AJOL)

    Prof. Mereku

    2010-08-15

    Aug 15, 2010 ... African Journal of Educational Studies in Mathematics and Sciences Vol. ... girls from two Senior High Schools in Accra, the capital of Ghana in West Africa. .... On the face of it, the Brazilian and Swedish children might seem to have the ... The two profile dimensions that have been specified for teaching, ...

  11. Design and installation manual for thermal energy storage

    Energy Technology Data Exchange (ETDEWEB)

    Cole, R L; Nield, K J; Rohde, R R; Wolosewicz, R M [eds.

    1979-02-01

    The purpose for this manual is to provide information on the design and installation of thermal energy storage in solar heating systems. It is intended for contractors, installers, solar system designers, engineers, architects, and manufacturers who intend to enter the solar energy business. The reader should have general knowledge of how solar heating systems operate and knowledge of construction methods and building codes. Knowledge of solar analysis methods such as f-chart, SOLCOST, DOE-1, or TRNSYS would be helpful. The information contained in the manual includes sizing storage, choosing a location for the storage device, and insulation requirements. Both air-based and liquid-based systems are covered with topics on designing rock beds, tank types, pump and fan selection, installation, costs, and operation and maintenance. Topics relevant to heating domestic water include safety, single- and dual-tank systems, domestic water heating with air- and liquid-based space heating system, and stand-alone domestic hot water systems. Several appendices present common problems with storage systems and their solutions, heat transfer fluid properties, heat exchanger sizing, and sample specifications for heat exchangers, wooden rock bins, steel tanks, concrete tanks, and fiberglass-reinforced plastic tanks.

  12. Wind tunnel evaluation of Hi-Vol TSP effectiveness data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Wind tunnel evaluation of EPA's Hi-Vol TSP sampler for sampling effectiveness with regards to aerodynamic particle diameter (5 to 35 microns), wind speed (2, 8, 24...

  13. Manual and computerized measurement of coronal vertebral inclination on MRI images: A pilot study

    International Nuclear Information System (INIS)

    Vrtovec, T.; Likar, B.; Pernuš, F.

    2013-01-01

    Aim: A pilot study that presents a systematic approach for evaluating the variability of manual and computerized measurements of coronal vertebral inclination (CVI) on images acquired by magnetic resonance imaging (MRI). Materials and methods: Three observers identified the vertebral body corners of 28 vertebrae on two occasions on two-dimensional (2D) coronal MRI cross-sections, which served to evaluate CVI using six manual measurements (superior and inferior tangents, left and right tangents, mid-endplate and mid-wall lines). Computerized measurements were performed by evaluating CVI from the symmetry of vertebral anatomical structures of the same 28 vertebrae in 2D coronal MRI cross-sections and in three-dimensional (3D) MRI images. Results: In terms of standard deviation (SD), the mid-endplate lines proved to be the manual measurements with the lowest intra- (1.0° SD) and interobserver (1.4° SD) variability. The computerized measurements in 3D yielded even lower intra- (0.8° SD) and interobserver (1.3° SD) variability. The strongest inter-method agreement (1.2° SD) was found among lines parallel to vertebral endplates (superior tangents, inferior tangents, mid-endplate lines). The computerized measurements in 3D were most in agreement with the mid-endplate lines (1.9° SD). The estimated intra- and interobserver variabilities of standard Cobb angle measurements were equal to 1.6° SD and 2.5° SD, respectively, for manual measurements, and to 1.1° SD and 1.8° SD, respectively, for computerized measurements. Conclusion: The mid-endplate lines proved to be the most reproducible and reliable manual CVI measurements. Computerized CVI measurements based on the evaluation of the symmetry of vertebral anatomical structures in 3D were more reproducible and reliable than manual measurements

  14. WE-AB-BRA-05: Fully Automatic Segmentation of Male Pelvic Organs On CT Without Manual Intervention

    International Nuclear Information System (INIS)

    Gao, Y; Lian, J; Chen, R; Wang, A; Shen, D

    2015-01-01

    Purpose: We aim to develop a fully automatic tool for accurate contouring of major male pelvic organs in CT images for radiotherapy without any manual initialization, yet still achieving superior performance than the existing tools. Methods: A learning-based 3D deformable shape model was developed for automatic contouring. Specifically, we utilized a recent machine learning method, random forest, to jointly learn both image regressor and classifier for each organ. In particular, the image regressor is trained to predict the 3D displacement from each vertex of the 3D shape model towards the organ boundary based on the local image appearance around the location of this vertex. The predicted 3D displacements are then used to drive the 3D shape model towards the target organ. Once the shape model is deformed close to the target organ, it is further refined by an organ likelihood map estimated by the learned classifier. As the organ likelihood map provides good guideline for the organ boundary, the precise contouring Result could be achieved, by deforming the 3D shape model locally to fit boundaries in the organ likelihood map. Results: We applied our method to 29 previously-treated prostate cancer patients, each with one planning CT scan. Compared with manually delineated pelvic organs, our method obtains overlap ratios of 85.2%±3.74% for the prostate, 94.9%±1.62% for the bladder, and 84.7%±1.97% for the rectum, respectively. Conclusion: This work demonstrated feasibility of a novel machine-learning based approach for accurate and automatic contouring of major male pelvic organs. It shows the potential to replace the time-consuming and inconsistent manual contouring in the clinic. Also, compared with the existing works, our method is more accurate and also efficient since it does not require any manual intervention, such as manual landmark placement. Moreover, our method obtained very similar contouring results as the clinical experts. Project is partially support

  15. WE-AB-BRA-05: Fully Automatic Segmentation of Male Pelvic Organs On CT Without Manual Intervention

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Y; Lian, J; Chen, R; Wang, A; Shen, D [Univ North Carolina, Chapel Hill, NC (United States)

    2015-06-15

    Purpose: We aim to develop a fully automatic tool for accurate contouring of major male pelvic organs in CT images for radiotherapy without any manual initialization, yet still achieving superior performance than the existing tools. Methods: A learning-based 3D deformable shape model was developed for automatic contouring. Specifically, we utilized a recent machine learning method, random forest, to jointly learn both image regressor and classifier for each organ. In particular, the image regressor is trained to predict the 3D displacement from each vertex of the 3D shape model towards the organ boundary based on the local image appearance around the location of this vertex. The predicted 3D displacements are then used to drive the 3D shape model towards the target organ. Once the shape model is deformed close to the target organ, it is further refined by an organ likelihood map estimated by the learned classifier. As the organ likelihood map provides good guideline for the organ boundary, the precise contouring Result could be achieved, by deforming the 3D shape model locally to fit boundaries in the organ likelihood map. Results: We applied our method to 29 previously-treated prostate cancer patients, each with one planning CT scan. Compared with manually delineated pelvic organs, our method obtains overlap ratios of 85.2%±3.74% for the prostate, 94.9%±1.62% for the bladder, and 84.7%±1.97% for the rectum, respectively. Conclusion: This work demonstrated feasibility of a novel machine-learning based approach for accurate and automatic contouring of major male pelvic organs. It shows the potential to replace the time-consuming and inconsistent manual contouring in the clinic. Also, compared with the existing works, our method is more accurate and also efficient since it does not require any manual intervention, such as manual landmark placement. Moreover, our method obtained very similar contouring results as the clinical experts. Project is partially support

  16. COMPARISON OF MANUAL AND SEMIAUTOMATED FUNDUS AUTOFLUORESCENCE ANALYSIS OF MACULAR ATROPHY IN STARGARDT DISEASE PHENOTYPE.

    Science.gov (United States)

    Kuehlewein, Laura; Hariri, Amir H; Ho, Alexander; Dustin, Laurie; Wolfson, Yulia; Strauss, Rupert W; Scholl, Hendrik P N; Sadda, SriniVas R

    2016-06-01

    To evaluate manual and semiautomated grading techniques for assessing decreased fundus autofluorescence (DAF) in patients with Stargardt disease phenotype. Certified reading center graders performed manual and semiautomated (region finder-based) grading of confocal scanning laser ophthalmoscopy (cSLO) fundus autofluorescence (FAF) images for 41 eyes of 22 patients. Lesion types were defined based on the black level and sharpness of the border: definite decreased autofluorescence (DDAF), well, and poorly demarcated questionably decreased autofluorescence (WDQDAF, PDQDAF). Agreement in grading between the two methods and inter- and intra-grader agreement was assessed by kappa coefficients (κ) and intraclass correlation coefficients (ICC). The mean ± standard deviation (SD) area was 3.07 ± 3.02 mm for DDAF (n = 31), 1.53 ± 1.52 mm for WDQDAF (n = 9), and 6.94 ± 10.06 mm for PDQDAF (n = 17). The mean ± SD absolute difference in area between manual and semiautomated grading was 0.26 ± 0.28 mm for DDAF, 0.20 ± 0.26 mm for WDQDAF, and 4.05 ± 8.32 mm for PDQDAF. The ICC (95% confidence interval) for method comparison was 0.992 (0.984-0.996) for DDAF, 0.976 (0.922-0.993) for WDQDAF, and 0.648 (0.306-0.842) for PDQDAF. Inter- and intra-grader agreement in manual and semiautomated quantitative grading was better for DDAF (0.981-0.996) and WDQDAF (0.995-0.999) than for PDQDAF (0.715-0.993). Manual and semiautomated grading methods showed similar levels of reproducibility for assessing areas of decreased autofluorescence in patients with Stargardt disease phenotype. Excellent agreement and reproducibility were observed for well demarcated lesions.

  17. ASSESSING THE AGREEMENT BETWEEN EO-BASED SEMI-AUTOMATED LANDSLIDE MAPS WITH FUZZY MANUAL LANDSLIDE DELINEATION

    Directory of Open Access Journals (Sweden)

    F. Albrecht

    2017-09-01

    Full Text Available Landslide mapping benefits from the ever increasing availability of Earth Observation (EO data resulting from programmes like the Copernicus Sentinel missions and improved infrastructure for data access. However, there arises the need for improved automated landslide information extraction processes from EO data while the dominant method is still manual delineation. Object-based image analysis (OBIA provides the means for the fast and efficient extraction of landslide information. To prove its quality, automated results are often compared to manually delineated landslide maps. Although there is awareness of the uncertainties inherent in manual delineations, there is a lack of understanding how they affect the levels of agreement in a direct comparison of OBIA-derived landslide maps and manually derived landslide maps. In order to provide an improved reference, we present a fuzzy approach for the manual delineation of landslides on optical satellite images, thereby making the inherent uncertainties of the delineation explicit. The fuzzy manual delineation and the OBIA classification are compared by accuracy metrics accepted in the remote sensing community. We have tested this approach for high resolution (HR satellite images of three large landslides in Austria and Italy. We were able to show that the deviation of the OBIA result from the manual delineation can mainly be attributed to the uncertainty inherent in the manual delineation process, a relevant issue for the design of validation processes for OBIA-derived landslide maps.

  18. Possible adverse events in children treated by manual therapy: a review

    Directory of Open Access Journals (Sweden)

    Humphreys B Kim

    2010-06-01

    Full Text Available Abstract Background Pediatric manual therapy is controversial within the medical community particularly with respect to adverse events. Pediatric manual therapy (Ped MT is commonly used by a number of professions such as chiropractors, osteopaths and naturopaths for a variety of treatments in children. Ped MT interventions range from advice, light touch, massage, through to mobilisation and high velocity spinal manipulation. However, current evidence related to adverse events associated with Ped MT is not well understood. Objective To update the clinical research literature from the 2007 report by Vohra, Johnston, Cramer and Humphreys on possible adverse events in children treated by spinal manipulation. Methods A review of the clinical research literature from June 2004 until January 2010 as reported in MEDLINE, PubMed and PubMed Central for adverse events specifically related to the treatment of pediatric cases by manual therapy. Results Only three new clinical studies, one systematic review with meta-analysis and one evidence report were identified. Two clinical studies reported on chiropractic care and one on osteopathic spinal manipulation in children. The systematic review investigated all studies of adverse events and manual therapy and was not specific for pediatric patients. The evidence review focused on effectiveness of spinal manipulation in a variety of musculoskeletal conditions. No serious or catastrophic adverse events were reported in the clinical studies or systematic review. However for adults, it has been estimated that between 0.003% and 0.13% of manual therapy treatments may result in a serious adverse event. Although mild to moderate adverse events are common in adults, an accurate estimate from high quality pediatric studies is currently not available. Conclusions There is currently insufficient research evidence related to adverse events and manual therapy. However, clinical studies and systematic reviews from adult

  19. MANUAL LOGIC CONTROLLER (MLC)

    OpenAIRE

    Claude Ziad Bayeh

    2015-01-01

    The “Manual Logic Controller” also called MLC, is an electronic circuit invented and designed by the author in 2008, in order to replace the well known PLC (Programmable Logic Controller) in many applications for its advantages and its low cost of fabrication. The function of the MLC is somewhat similar to the well known PLC, but instead of doing it by inserting a written program into the PLC using a computer or specific software inside the PLC, it will be manually programmed in a manner to h...

  20. Security electronics circuits manual

    CERN Document Server

    MARSTON, R M

    1998-01-01

    Security Electronics Circuits Manual is an invaluable guide for engineers and technicians in the security industry. It will also prove to be a useful guide for students and experimenters, as well as providing experienced amateurs and DIY enthusiasts with numerous ideas to protect their homes, businesses and properties.As with all Ray Marston's Circuits Manuals, the style is easy-to-read and non-mathematical, with the emphasis firmly on practical applications, circuits and design ideas. The ICs and other devices used in the practical circuits are modestly priced and readily available ty

  1. Towards Automatic Capturing of Manual Data Processing Provenance

    NARCIS (Netherlands)

    Wombacher, Andreas; Huq, M.R.

    2011-01-01

    Often data processing is not implemented by a work ow system or an integration application but is performed manually by humans along the lines of a more or less specified procedure. Collecting provenance information during manual data processing can not be automated. Further, manual collection of

  2. Manual therapy as a conservative treatment for adolescent idiopathic scoliosis: a systematic review

    Directory of Open Access Journals (Sweden)

    Negrini Stefano

    2008-01-01

    Full Text Available Abstract Background The treatment of adolescent idiopathic scoliosis is contingent upon many variables. Simple observation is enough for less serious curvatures, but for very serious cases surgical intervention could be proposed. Between these there is a wide range of different treatments. Manual therapy is commonly used: the aim of this paper is to verify the data existing in the literature on the efficacy of this approach. Methods A systematic review of the scientific literature published internationally has been performed. We have included in the term manual therapy all the manipulative and generally passive techniques performed by an external operator. In a more specific meaning, osteopathic, chiropractic and massage techniques have been considered as manipulative therapeutic methods. We performed our systematic research in Medline, Embase, Cinhal, Cochrane Library, Pedro with the following terms: idiopathic scoliosis combined with chiropractic; manipulation; mobilization; manual therapy; massage; osteopathy; and therapeutic manipulation. The criteria for inclusion were as follows: Any kind of research; diagnosis of adolescent idiopathic scoliosis; patients treated exclusively by one of the procedures established as a standard for this review (chiropractic manipulation, osteopathic techniques, massage; and outcome in Cobb degrees. Results We founded 145 texts, but only three papers were relevant to our study. However, no one of the three satisfied all the required inclusion criteria because they were characterized by a combination of manual techniques and other therapeutic approaches. Conclusion The lack of any kind of serious scientific data does not allow us to draw any conclusion on the efficacy of manual therapy as an efficacious technique for the treatment of Adolescent idiopathic scoliosis.

  3. Manual In-Line Stabilization of the Cervical Spine Increases the ...

    African Journals Online (AJOL)

    injury present with loss of consciousness and suspected cervical fracture. The aim of this study was to determine the rate of difficult orotracheal intubation in surgical patients undergoing various procedures when manual in-line neck immobilization technique was applied. Methods: This was a randomized prospective study ...

  4. Creating Web Sites The Missing Manual

    CERN Document Server

    MacDonald, Matthew

    2006-01-01

    Think you have to be a technical wizard to build a great web site? Think again. For anyone who wants to create an engaging web site--for either personal or business purposes--Creating Web Sites: The Missing Manual demystifies the process and provides tools, techniques, and expert guidance for developing a professional and reliable web presence. Like every Missing Manual, you can count on Creating Web Sites: The Missing Manual to be entertaining and insightful and complete with all the vital information, clear-headed advice, and detailed instructions you need to master the task at hand. Autho

  5. Torque and power outputs on different subjects during manual wheelchair propulsion under different conditions

    Science.gov (United States)

    Hwang, Seonhong; Kim, Seunghyeon; Son, Jongsang; Kim, Youngho

    2012-02-01

    Manual wheelchair users are at a high risk of pain and injuries to the upper extremities due to mechanical inefficiency of wheelchair propulsion motion. The kinetic analysis of the upper extremities during manual wheelchair propulsion in various conditions needed to be investigated. We developed and calibrated a wheelchair dynamometer for measuring kinetic parameters during propulsion. We utilized the dynamometer to investigate and compare the propulsion torque and power values of experienced and novice users under four different conditions. Experienced wheelchair users generated lower torques with more power than novice users and reacted alertly and sensitively to changing conditions. We expect that these basic methods and results may help to quantitatively evaluate the mechanical efficiency of manual wheelchair propulsion.

  6. Journal of Applied Sciences and Environmental Management - Vol ...

    African Journals Online (AJOL)

    Journal of Applied Sciences and Environmental Management. ... AFRICAN JOURNALS ONLINE (AJOL) · Journals · Advanced Search · USING ... Journal of Applied Sciences and Environmental Management - Vol 22, No 4 (2018) ... Evaluating the effect of mobility speed on the performance of three handover algorithms in ...

  7. Shostakovich: The Orchestral Songs Vol. 2 / Michael Tanner

    Index Scriptorium Estoniae

    Tanner, Michael

    1996-01-01

    Uuest heliplaadist "Shostakovich: The Orchestral Songs Vol. 2: Six Romances on texts by Japanese poets, Op. 21. Six Poems on Marina Tsvetayeva, Op. 143. Suite on Verses of Michelangelo, Op. 145. Gothenburg Symphony Orchestra, Neeme Järvi". DG 447 085-2GH (71 minutes:DDD)

  8. Biological Methods and Manual Development

    Science.gov (United States)

    EPA scientists conduct research to develop and evaluate analytical methods for the identification, enumeration, evaluation of aquatic organisms exposed to environmental stressors and to correlate exposures with effects on chemical and biological indicators

  9. The Northern States Power Company welding manual advisor

    International Nuclear Information System (INIS)

    Lu, Yi; Wood, R.M.

    1993-01-01

    The Welding Manual Advisor (WMA) is an object oriented expert system designed to assist Northern States Power (NSP) personnel in implementing the company's Welding Manual. The expert system captures the knowledge of welding experts, addresses important issues in welding activities and automates the use of the Welding Manual. It is estimated that use of the WMA will save $81,000 over the next six years at NSP, because of the reduction of labor and errors in the use of the Welding Manual, and facilitation of training of NSP personnel. The important features of the WMA include the accuracy and consistency in determining welding procedure and requirements, update capability, user friendly interface, on-line help function, back-up capability, and well-documented manuals

  10. Missouri DECA: 2010-2011 Policy Manual

    Science.gov (United States)

    Missouri Department of Elementary and Secondary Education, 2011

    2011-01-01

    This paper presents the Missouri DECA Policy Manual. This manual contains the following sections: (1) DECA Board of Directors; (2) State Sales Projects; (3) State Officers; (4) Districts; (5) Competitive Events; (6) General Conference Information; (7) Fall Leadership & State Officer Election Conference; (8) Central Region Leadership…

  11. NDS EXFOR manual

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1985-08-01

    EXFOR is the agreed exchange format for the transmission of nuclear reaction data between national and international nuclear data centers for the benefit of nuclear data users in all countries. The IAEA Nuclear Data Section uses the EXFOR system not only for the center-to-center data exchange but also as its data storage and retrieval system. This NDS EXFOR MANUAL therefore contains the agreed EXFOR coding rules and format, supplemented by NDS internal compilation rules. The EXFOR system and the EXFOR nuclear data library with several million data records originate from the cooperation of an increasing number of data centers whose names and addresses can be found inside the Manual. Their contributions and cooperative efforts are gratefully acknowledged. (author)

  12. REBA experimenters' manual

    International Nuclear Information System (INIS)

    Schuch, R.L.

    1977-04-01

    The REBA is a high-energy, pulsed electron beam or bremsstrahlung x-ray generator whose operational purpose is to provide an energy source of short duration for conducting experiments, primarily to determine material responses to rapid surface and in-depth deposition of energy. The purpose of this manual is to serve as a basic source of information for prospective users of REBA. Included is a brief discussion of the design and operation of the facility as well as a summary of output characteristics for electron beam modes and environmental data for x-ray operation. The manual also contains a description of the REBA experimental facilities, including geometry of the test cell, instrumentation and data collection capabilities, and services and support available to experimenters

  13. NDS EXFOR manual

    International Nuclear Information System (INIS)

    Lemmel, H.D.

    1996-01-01

    EXFOR is the agreed exchange format for the transmission of nuclear reaction data between national and international nuclear data centers for the benefit of nuclear data users in all countries. The IAEA Nuclear Data Section uses the EXFOR system not only for the center-to-center data exchange but also as its data storage and retrieval system. This NDS EXFOR MANUAL therefore contains the agreed EXFOR coding rules and format, supplemented by NDS internal compilation rules. The EXFOR system and the EXFOR nuclear data library with several million data records originate from the cooperation of an increasing number of data centers whose names and addresses can be found inside the Manual. Their contributions and cooperative efforts are gratefully acknowledged. (author)

  14. African Journal of Biotechnology - Vol 14, No 18 (2015)

    African Journals Online (AJOL)

    African Journal of Biotechnology - Vol 14, No 18 (2015). Journal Home ... Isolation of microalgae species from arid environments and evaluation of their potentials for biodiesel production · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  15. Jolivet: Complete Flute Music, Vol. 2 / Guy S. Rickards

    Index Scriptorium Estoniae

    Rickards, Guy S.

    1996-01-01

    Uuest heliplaadist "Jolivet: Complete Flute Music, Vol. 2. Kroumata Percussion Ensemble, Tapiola Sinfonietta, Paavo Järvi". BIS CD 739 (64 minutes: DDD). Item marked from CD630 (6/94), CD272, remainder new to UK

  16. 21 CFR 866.2180 - Manual colony counter.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2180 Manual colony counter. (a) Identification. A manual colony counter is a device intended for medical purposes that consists...

  17. Rooftop Unit Comparison Calculator User Manual

    Energy Technology Data Exchange (ETDEWEB)

    Miller, James D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-04-30

    This document serves as a user manual for the Packaged rooftop air conditioners and heat pump units comparison calculator (RTUCC) and is an aggregation of the calculator’s website documentation. Content ranges from new-user guide material like the “Quick Start” to the more technical/algorithmic descriptions of the “Methods Pages.” There is also a section listing all the context-help topics that support the features on the “Controls” page. The appendix has a discussion of the EnergyPlus runs that supported the development of the building-response models.

  18. GO methodology. Volume 1. Overview manual

    International Nuclear Information System (INIS)

    1983-06-01

    The GO methodology is a success-oriented probabilistic system performance analysis technique. The methodology can be used to quantify system reliability and availability, identify and rank critical components and the contributors to system failure, construct event trees, and perform statistical uncertainty analysis. Additional capabilities of the method currently under development will enhance its use in evaluating the effects of external events and common cause failures on system performance. This Overview Manual provides a description of the GO Methodology, how it can be used, and benefits of using it in the analysis of complex systems

  19. State Energy Program Operations Manual

    Energy Technology Data Exchange (ETDEWEB)

    Office of Building Technology, State and Community Programs

    1999-03-17

    The State Energy Program Operations Manual is a reference tool for the states and the program officials at the U.S. Department of Energy's Office of Building Technology, State and Community Programs and Regional Support Offices as well as State Energy Offices. The Manual contains information needed to apply for and administer the State Energy Program, including program history, application rules and requirements, and program administration and monitoring requirements.

  20. African Journal of Clinical and Experimental Microbiology - Vol 5, No ...

    African Journals Online (AJOL)

    African Journal of Clinical and Experimental Microbiology - Vol 5, No 1 (2004) ... ASYMPTOMATIC SIGNIFICANT BACTERIURIA AMONG PREGNANT WOMEN IN ... TO PARASITISM AND THE IMPLICATION ON TREATMENT APPROACH ...

  1. Perception and acceptance of technological risks. Vol. 3

    Energy Technology Data Exchange (ETDEWEB)

    Renn, O

    1981-01-01

    Vol. 3 discusses the problem of attitudes towards nuclear power. Data are compiled for five communities in North-Rhine Westphalia with nuclear facilities and the control community of Kerpen, which has no nuclear power plant. At the same time, the empirical and theoretical investigations are comprehensively evaluated.

  2. Manual for a Volunteer Services System.

    Science.gov (United States)

    Helgerson, Linda; And Others

    This manual presents guidelines for planning, monitoring, and controlling the development and operation of volunteer assistance programs. The materials included address questions related to both the process of establishing a volunteer program and the administration of a volunteer management system. The manual is not intended to provide a blueprint…

  3. Host Families Matter: The Homestay Manual.

    Science.gov (United States)

    Peace Corps, Washington, DC. Information Collection and Exchange Div.

    This manual provides guidelines, sample documents, and sample lesson plans for the trainers, trainees, and host families involved in homestays for Peace Corps volunteers. The manual contains 11 sections that deal with the following topics: (1) introduction; (2) policy, timelines, and responsibilities; (3) medical and financial issues; (4) host…

  4. 21 CFR 886.1770 - Manual refractor.

    Science.gov (United States)

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1770 Manual refractor. (a) Identification. A manual refractor is a device that is a set of lenses of varous dioptric powers intended to measure the refractive error of the eye. (b) Classification. Class I (general controls). The device is exempt from the...

  5. Southern African Journal of Environmental Education - Vol 8 (1988)

    African Journals Online (AJOL)

    Southern African Journal of Environmental Education - Vol 8 (1988) ... An interaction of archaeology with school history in a museum education context ... The child in the outdoor classroom · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  6. Research in Hospitality Management - Vol 5, No 2 (2015)

    African Journals Online (AJOL)

    Research in Hospitality Management - Vol 5, No 2 (2015) ... Hotel quality in the European Capital of Culture: Leeuwarden 2018 · EMAIL FREE FULL ... Consumer patronage and willingness-to-pay at different levels of restaurant attributes: A ...

  7. 21 CFR 890.5180 - Manual patient rotation bed.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Therapeutic Devices § 890.5180 Manual patient rotation bed. (a) Identification. A manual patient rotation bed is a device that turns a patient who is... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual patient rotation bed. 890.5180 Section 890...

  8. TV Trouble-Shooting Manual. Volumes 7-8. Part 3: Synchronisation and Deflection Circuits. Student and Instructor's Manuals.

    Science.gov (United States)

    Mukai, Masaaki; Kobayashi, Ryozo

    These volumes are, respectively, the self-instructional student manual and the teacher manual that cover the third set of training topics in this course for television repair technicians. Both contain identical information on synchronization and deflection circuits, including sections on the principle of synchronized deflection, synchronization…

  9. The energy management manual for arena and rink operators

    Energy Technology Data Exchange (ETDEWEB)

    Raymer, M. [Saskatchewan Parks and Recreation Assoc., Regina, SK (Canada); White, T. [Office of Energy Conservation, Regina, SK (Canada); Kozoriz, D.F. [SaskPower, Regina, SK (Canada); Norman, D. [SaskPower, Saskatoon, SK (Canada)

    2006-08-15

    In an era when energy costs often rise faster than the community tax base, energy conservation plays a key role in ensuring that skating arenas are able to continue operating. This manual on energy management for arena and rink operators includes current technologies and practices that reduce operating costs. It is meant to help in the training and education of all facility operators. Since fossil fuels are the main source of electrical generation in Saskatchewan, reducing energy consumption directly reduces greenhouse gas emissions to the environment. This manual included a brief introduction to energy calculations for operators of rinks and arenas. The calculations can be performed for the heat loss that occurs in winter and the amount of heat input needed to maintain temperatures. It was recommended that the more difficult calculation of estimating the amount of cooling required for ice making should be done by qualified consultants. The 10 sections of the manual addressed the issues of: (1) electrical and natural gas rates, (2) meters and electrical inventory, (3) making a financial analysis, (4) the building envelope, (5) heating and ventilation, (6) refrigeration, (7) lighting, (8) heating effects of electrical equipment, (9) operation and maintenance, and, (10) project planning. The manual also presented methods to improve the power factor by adding relatively inexpensive components, such as capacitors, to lower electricity bills by as much as 20 per cent. A review of geo-exchange systems for rinks and arenas was included along with heat recovery from refrigeration systems and financial assistance for commercial, institutional and municipal buildings. refs., tabs., figs.

  10. Unraveling the Mechanisms of Manual Therapy: Modeling an Approach.

    Science.gov (United States)

    Bialosky, Joel E; Beneciuk, Jason M; Bishop, Mark D; Coronado, Rogelio A; Penza, Charles W; Simon, Corey B; George, Steven Z

    2018-01-01

    Synopsis Manual therapy interventions are popular among individual health care providers and their patients; however, systematic reviews do not strongly support their effectiveness. Small treatment effect sizes of manual therapy interventions may result from a "one-size-fits-all" approach to treatment. Mechanistic-based treatment approaches to manual therapy offer an intriguing alternative for identifying patients likely to respond to manual therapy. However, the current lack of knowledge of the mechanisms through which manual therapy interventions inhibit pain limits such an approach. The nature of manual therapy interventions further confounds such an approach, as the related mechanisms are likely a complex interaction of factors related to the patient, the provider, and the environment in which the intervention occurs. Therefore, a model to guide both study design and the interpretation of findings is necessary. We have previously proposed a model suggesting that the mechanical force from a manual therapy intervention results in systemic neurophysiological responses leading to pain inhibition. In this clinical commentary, we provide a narrative appraisal of the model and recommendations to advance the study of manual therapy mechanisms. J Orthop Sports Phys Ther 2018;48(1):8-18. doi:10.2519/jospt.2018.7476.

  11. Estudo comparativo das medidas manual e digital da fenda palpebral A comparative study of the manual and digital measurements of the palpebral fissure

    Directory of Open Access Journals (Sweden)

    Tânia Pereira Nunes

    2005-12-01

    Full Text Available OBJETIVO: Comparar a medida manual do comprimento vertical da fenda palpebral e sua medida obtida por meio de processamento computadorizado de imagens de indivíduos sem alterações palpebrais. MÉTODOS: Foram analisadas 102 fendas palpebrais de 51 indivíduos normais. A faixa etária variou entre 17 e 84 anos, sendo 25 (49% do sexo masculino e 26 (51% do sexo feminino. RESULTADOS: Não houve diferença estatisticamente significativa entre as medidas manuais da fenda palpebral e as obtidas por meio de processamento computadorizado de imagens. Também não se observou diferença entre ambos os sexos e a faixa etária. CONCLUSÕES: Os resultados obtidos com estes dois métodos podem ser comparados entre si devida à equivalência estatística das medidas.PURPOSE: To compare the measurement of the palpebral fissure done either manually and by computer analysis of image of individuals without lid alterations. METHODS: One hundred two palpebral fissures from 51 normal subjects have been analyzed. The patients' age ranged from 17 to 84 years, with 25 (49% males and 26 (51% females. RESULTS: There was no statistically significant difference between the measurements done either manually or by computer analysis of images, neither, when we grouped the patients by sex or age. Also we did not observe difference between males and females, and regarding age. CONCLUSIONS: The results obtained by both methods are comparable and reliable due to the statistical equivalence of the obtained measurements.

  12. Manual for SFR R and D and Technology Monitoring System Administrator

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Uk; Lee, Yong Bum; Won, Byung Chool; Kim, Young In; Hahn, Do Hee

    2008-05-15

    This report is a administrator manual on R and D and technology monitoring system that is applicable for managing the generation IV sodium-cooled fast reactor development. First of all, enterprise project management solution is introduced and then enterprise resources and data creation method are described. Also it made a description of project web assess design, data management method etc.

  13. Viscous wing theory development. Volume 2: GRUMWING computer program user's manual

    Science.gov (United States)

    Chow, R. R.; Ogilvie, P. L.

    1986-01-01

    This report is a user's manual which describes the operation of the computer program, GRUMWING. The program computes the viscous transonic flow over three-dimensional wings using a boundary layer type viscid-inviscid interaction approach. The inviscid solution is obtained by an approximate factorization (AFZ)method for the full potential equation. The boundary layer solution is based on integral entrainment methods.

  14. Manual for SFR R and D and Technology Monitoring System Administrator

    International Nuclear Information System (INIS)

    Lee, Dong Uk; Lee, Yong Bum; Won, Byung Chool; Kim, Young In; Hahn, Do Hee

    2008-05-01

    This report is a administrator manual on R and D and technology monitoring system that is applicable for managing the generation IV sodium-cooled fast reactor development. First of all, enterprise project management solution is introduced and then enterprise resources and data creation method are described. Also it made a description of project web assess design, data management method etc

  15. AKURASI HITUNG JUMLAH ERITROSIT METODE MANUAL DAN METODE OTOMATIS

    Directory of Open Access Journals (Sweden)

    Neni Oktiyani

    2017-12-01

    Full Text Available Hitung jumlah eritrosit dilakukan dengan menggunakan metode manual dan metode otomatis. Metode manual menggunakan alat Hemositometer dapat memberikan hasil yang dipercaya dan akurat tergantung keahlian dari teknisi laboratorium. Metode otomatis memberikan hasil yang lebih mudah, cepat dan teliti dibandingkan dengan cara manual. Tujuan penelitian untuk membandingkan akurasi hitung jumlah eritrosit metode manual dan metode otomatis. Jenis penelitian yang digunakan adalah survey analitik dengan rancangan cross sectional. Penelitian ini membandingkan data hasil hitung jumlah eritrosit antara metode manual dengan metode otomatis dengan menggunakan 3 jenis darah kontrol hitung jumlah eritrosit high, normal, dan low dengan 9 kali pengulangan. Hasil penelitian menunjukkan nilai rerata hitung jumlah eritrosit darah kontrol high metode manual sebesar 7,08 juta/µl dengan nilai bias 1,4% dan metode otomatis sebesar 7,03 juta/µl dengan nilai bias 0,7%. Rerata hitung jumlah eritrosit darah kontrol normal metode manual sebesar 4,50 juta/µl dengan nilai bias 0,9% dan metode otomatis sebesar 4,43 juta/µl dengan nilai bias 2,4%. Rerata hitung jumlah eritrosit darah kontrol low metode manual sebesar 1,72 juta/µl dengan nilai bias 4,4% dan metode otomatis sebesar 1,67 juta/µl dengan nilai bias 1,2%. Uji statistik menunjukkan tidak ada perbedaan akurasi yang bermakna antara hitung jumlah eritrosit metode manual dengan metode otomatis.

  16. Detection of Harmful Algal Toxins Using the Radioligand Receptor Binding Assay. A Manual of Methods

    International Nuclear Information System (INIS)

    2013-12-01

    of significant national, regional and interregional capabilities in algal toxin detection and monitoring, and management and mitigation of HABs associated with paralytic shellfish poisoning, diarrheic shellfish poisoning and ciguatera poisoning. In order to support and to facilitate the continuing effort of Member States to acquire, develop and sustain capabilities to address the impacts of HABs, the IAEA has taken the initiative to conceive and produce this manual of radioligand receptor binding assay methods. This is the first publication produced in collaboration with the NOAA and the Intergovernmental Oceanographic Commission of UNESCO (IOC UNESCO), the Philippine Nuclear Research Institute (an IAEA collaborating centre) and the Institut Louis Malarde in French Polynesia. It complements the Manual on Phytoplankton Sampling Techniques produced under the regional project RLA7014 and published by the IOC UNESCO. The series of well established nuclear techniques for early identification and quantification of HAB related toxins that are presented in this publication are intended to reduce the health and socioeconomic impacts of HAB events. The end users include national phytoplankton monitoring programmes with benefits to fisheries, research scientists, public health, communities, etc

  17. Sodium safety manual

    International Nuclear Information System (INIS)

    Hayes, D.J.; Gardiner, R.L.

    1980-09-01

    The sodium safety manual is based upon more than a decade of experience with liquid sodium at Berkeley Nuclear Laboratories (BNL). It draws particularly from the expertise and experience developed in the course of research work into sodium fires and sodium water reactions. It draws also on information obtained from the UKAEA and other sodium users. Many of the broad principles will apply to other Establishments but much of the detail is specific to BNL and as a consequence its application at other sites may well be limited. Accidents with sodium are at best unpleasant and at worst lethal in an extremely painful way. The object of this manual is to help prevent sodium accidents. It is not intended to give detailed advice on specific precautions for particular situations, but rather to set out the overall strategy which will ensure that sodium activities will be pursued safely. More detail is generally conveyed to staff by the use of local instructions known as Sodium Working Procedures (SWP's) which are not reproduced in this manual although a list of current SWP's is included. Much attention is properly given to the safe design and operation of larger facilities; nevertheless evidence suggests that sodium accidents most frequently occur in small-scale work particularly in operations associated with sodium cleaning and special care is needed in all such cases. (U.K.)

  18. Simply Great Cooking Instruction. A Manual for Teaching Cooking to Non-Reading Students.

    Science.gov (United States)

    Sesto, Cameron

    This manual presents a method of teaching cooking to nonreaders. The language of the method consists of visual symbols, such as drawings of bowls, spoons, and ingredients, and color. The "Simply Great" method consists of three basic formats: the one-step booklet, the full-page format, and the simply written for the student with some…

  19. Manual for JSSL (JAERI scientific subroutine library)

    International Nuclear Information System (INIS)

    Inoue, Shuji; Fujimura, Toichiro; Tsutsui, Tsuneo; Nishida, Takahiko

    1982-09-01

    A manual on revised version of JAERI scientific subroutine library, which is a collection of scientific subroutines developed or modified in JAERI. They are classified into fifteen fields (Special Functions, Linear Problems, Eigenvalue and Eigen vector Problems, Non linear Problems, Mathematical Programming, Extreme Value Problems, Transformations, Functional Approximation Methods, Numerical Differential and Integral Methods, Numerical Differential and Integral Equations, Statistical Functions, Physical Problems, I/O Routines, Plotter Routines, Computer System Functions and Others). Main expansion of this version is in the fields of mathematical programming and statistical functions. The present library may be said to be a comprehensive compilation of scientific subroutines covering almost all the important fields. (author)

  20. Equipment Qualification Data Base user manual

    International Nuclear Information System (INIS)

    Decker, Q.R.; Fackrell, L.J.; Fitch, L.R.; Meeky, O.B.

    1985-09-01

    This manual details the Equipment Qualification Data Base (EQDB), its usage, and contents. The EQDB consists of two files; the Plant Qualification File (PQF) and the Equipment Qualification File (EQF). The PQF contains plant specific environmental data and the EQF contains summaries of various test results. Two data management systems are used to manipulate the data and are discussed in this manual. SAS Institute System 2000 (S2K) is the management system for the PQF and Query Update (QU) is the operating system for the EQF. Each management system contains report writers. These writers and how to use them are discussed in detail in this manual

  1. South African Journal of Higher Education - Vol 19 (2005)

    African Journals Online (AJOL)

    South African Journal of Higher Education - Vol 19 (2005) ... The 'idea of engagement' and 'the African University in the 21st Century': Some ... The challenges of knowledge production by researchers in Public Administration, a South African ...

  2. Sierra Structural Dynamics Theory Manual

    Energy Technology Data Exchange (ETDEWEB)

    Reese, Garth M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-10-19

    Sierra/SD provides a massively parallel implementation of structural dynamics finite element analysis, required for high fidelity, validated models used in modal, vibration, static and shock analysis of structural systems. This manual describes the theory behind many of the constructs in Sierra/SD. For a more detailed description of how to use Sierra/SD , we refer the reader to Sierra/SD, User's Notes . Many of the constructs in Sierra/SD are pulled directly from published material. Where possible, these materials are referenced herein. However, certain functions in Sierra/SD are specific to our implementation. We try to be far more complete in those areas. The theory manual was developed from several sources including general notes, a programmer notes manual, the user's notes and of course the material in the open literature. This page intentionally left blank.

  3. Laboratory Waste Disposal Manual. Revised Edition.

    Science.gov (United States)

    Stephenson, F. G., Ed.

    This manual is designed to provide laboratory personnel with information about chemical hazards and ways of disposing of chemical wastes with minimum contamination of the environment. The manual contains a reference chart section which has alphabetical listings of some 1200 chemical substances with information on the health, fire and reactivity…

  4. Manual for Training Leprosy Rehabilitation Workers.

    Science.gov (United States)

    Itoh, Masayoshi; Eason, Alice L.

    The purpose of this manual is to introduce the general concepts and techniques in leprosy rehabilitation to physical therapy aides. Because of the lack of well-trained, qualified, physical therapists, the committee on leprosy rehabilitation considers it necessary to publish a teaching manual outlining leprosy rehabilitation for those who work with…

  5. Beyond the Manual Channel

    DEFF Research Database (Denmark)

    , the main focus there is on spoken languages in their written and spoken forms. This series of workshops, however, offers a forum for researchers focussing on sign languages. For the fourth time, the workshop had sign language corpora as its main topic. This time, the focus was on any aspect beyond...... the manual channel. Not surprisingly, most papers deal with non-manuals on the face. Once again, the papers at this workshop clearly identify the potentials of even closer cooperation between sign linguists and sign language engineers, and we think it is events like this that contribute a lot to a better...

  6. RELAP-7 Theory Manual

    Energy Technology Data Exchange (ETDEWEB)

    Berry, Ray Alden [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zou, Ling [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhao, Haihua [Idaho National Lab. (INL), Idaho Falls, ID (United States); Zhang, Hongbin [Idaho National Lab. (INL), Idaho Falls, ID (United States); Peterson, John William [Idaho National Lab. (INL), Idaho Falls, ID (United States); Martineau, Richard Charles [Idaho National Lab. (INL), Idaho Falls, ID (United States); Kadioglu, Samet Yucel [Idaho National Lab. (INL), Idaho Falls, ID (United States); Andrs, David [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-03-01

    This document summarizes the physical models and mathematical formulations used in the RELAP-7 code. In summary, the MOOSE based RELAP-7 code development is an ongoing effort. The MOOSE framework enables rapid development of the RELAP-7 code. The developmental efforts and results demonstrate that the RELAP-7 project is on a path to success. This theory manual documents the main features implemented into the RELAP-7 code. Because the code is an ongoing development effort, this RELAP-7 Theory Manual will evolve with periodic updates to keep it current with the state of the development, implementation, and model additions/revisions.

  7. Data collection system. Volume 1, Overview and operators manual; Volume 2, Maintenance manual; Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Caudell, R.B.; Bauder, M.E.; Boyer, W.B.; French, R.E.; Isidoro, R.J.; Kaestner, P.C.; Perkins, W.G.

    1993-09-01

    Sandia National Laboratories (SNL) Instrumentation Development Department was tasked by the Defense Nuclear Agency (DNA) to record data on Tektronix RTD720 Digitizers on the HUNTERS TROPHY field test conducted at the Nevada Test Site (NTS) on September 18, 1992. This report contains a overview and description of the computer hardware and software that was used to acquire, reduce, and display the data. The document is divided into two volumes: an overview and operators manual (Volume 1) and a maintenance manual (Volume 2).

  8. Determination of Residual Chlorine and Turbidity in Drinking Water. Student Manual.

    Science.gov (United States)

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This student's manual covers analytical methods for residual chlorine and turbidity. Topics include sample handling, permissable concentration levels, substitution of residual chlorine for bacteriological work, public notification, and the required analytical techniques to determine residual chlorine and turbidity. The publication is intended for…

  9. Mizan Law Review - Vol 5, No 2 (2011)

    African Journals Online (AJOL)

    Mizan Law Review - Vol 5, No 2 (2011) ... Ethiopian Law of International Carriage by Air: An Overview · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT ... Comment: Overview of the Core Changes in the New Ethiopian Urban Land Leasehold Proclamation · EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT

  10. Manuals of food quality control 10. training in mycotoxins analysis

    International Nuclear Information System (INIS)

    1991-01-01

    This manual is designed to cover a course of about three weeks to train food analysts in developing countries. Mycotoxins are described and analytical methods for detecting their presence in food and animal feeds are presented, with especial emphasis on immunoassay and thin-layer chromatographic procedures. 40 figs, 10 tabs

  11. Microscopic Analysis of Plankton, Periphyton, and Activated Sludge. Training Manual.

    Science.gov (United States)

    Environmental Protection Agency, Washington, DC. Office of Water Programs.

    This manual is intended for professional personnel in the fields of water pollution control, limnology, water supply and waste treatment. Primary emphasis is given to practice in the identification and enumeration of microscopic organisms which may be encountered in water and activated sludge. Methods for the chemical and instrumental evaluation…

  12. (JASR) Vol. 12, No. 2, 2012 DEPLETING FOREST RESOURCES

    African Journals Online (AJOL)

    HP

    deteriorating forest resources of Nigeria and its impact on climate change. Key words: Forest Resources, ... Mangrove Forest. Sub Total. 905,930 .... South America” Global Biogeographical Cycle vol 9, pp 329-350. Miller, K. R., Reid, W. V., ...

  13. Pan African Medical Journal - Vol 16, No 1 (2014)

    African Journals Online (AJOL)

    Pan African Medical Journal - Vol 16, No 1 (2014) .... Cancer incidence in Morocco: report from Casablanca registry 2005-2007 · EMAIL FREE FULL .... Maladie de Leo-Buerger faisant suite à une intoxication au cannabis · EMAIL FREE FULL ...

  14. African Heath Sciences Vol 8 No 1.p65

    African Journals Online (AJOL)

    Harriet

    African Health Sciences Vol 8 No 1 March 2008. 36 ... Objective:To highlight difficulties in the diagnosis and management of non-traumatic perforation of small bowel. Material and ..... of three operations for typhoid perforation. Br J Surg. 1997;.

  15. H. W. Laboratory manual: 100 Area section

    Energy Technology Data Exchange (ETDEWEB)

    1950-07-01

    The purpose of this manual is to present a Hazard Breakdown of all jobs normally encountered in the laboratory work of the three sections comprising the Analytic Section, Metallurgy and Control Division of the Technical Department. A Hazard Breakdown is a careful analysis of any job in which the source of possible dangers is clearly indicated for each particular step. The analysis is prepared by individuals who are thoroughly familiar with the specific job or procedure. It is felt that if the hazards herein outlined are recognized by the Laboratory personnel and the suggested safety cautions followed, the chance for injury will be minimized and the worker will become generally more safety conscious. The manual, which is prefaced by the general safety rules applying to all the laboratories, is divided into three main sections, one for each of the three sections into which the Laboratories Division is divided. These sections are as follows: Section 1 -- 200 Area Control; Section 2 -- 100 Area Control; Section 3 -- 300 Area Control, Essential Materials, and Methods Improvement.

  16. Matematica 2. Manual do Professor (Mathematics 2. Teacher's Manual).

    Science.gov (United States)

    D'Alu, Maria Jose Miranda de Sousa

    This teacher's manual accompanies a mathematics textbook for second graders, written in Portuguese. Developed from objectives set forth by the National Portuguese Materials Development Center, it follows closely the objectives and methodology of major curricula used in schools of the United States. Consideration was given to the Portuguese child's…

  17. Phantom Study Investigating the Accuracy of Manual and Automatic Image Fusion with the GE Logiq E9: Implications for use in Percutaneous Liver Interventions

    Energy Technology Data Exchange (ETDEWEB)

    Burgmans, Mark Christiaan, E-mail: m.c.burgmans@lumc.nl; Harder, J. Michiel den, E-mail: chiel.den.harder@gmail.com; Meershoek, Philippa, E-mail: P.Meershoek@lumc.nl [Leiden University Medical Centre, Department of Radiology (Netherlands); Berg, Nynke S. van den, E-mail: N.S.van-den-Berg@lumc.nl [Leiden University Medical Center, Interventional and Molecular Imaging Laboratory, Department of Radiology (Netherlands); Chan, Shaun Xavier Ju Min, E-mail: shaun.xavier.chan@singhealth.com.sg [Singapore General Hospital, Department of Interventional Radiology (Singapore); Leeuwen, Fijs W. B. van, E-mail: F.W.B.van-Leeuwen@lumc.nl [Leiden University Medical Center, Interventional and Molecular Imaging Laboratory, Department of Radiology (Netherlands); Erkel, Arian R. van, E-mail: a.r.van-erkel@lumc.nl [Leiden University Medical Centre, Department of Radiology (Netherlands)

    2017-06-15

    PurposeTo determine the accuracy of automatic and manual co-registration methods for image fusion of three-dimensional computed tomography (CT) with real-time ultrasonography (US) for image-guided liver interventions.Materials and MethodsCT images of a skills phantom with liver lesions were acquired and co-registered to US using GE Logiq E9 navigation software. Manual co-registration was compared to automatic and semiautomatic co-registration using an active tracker. Also, manual point registration was compared to plane registration with and without an additional translation point. Finally, comparison was made between manual and automatic selection of reference points. In each experiment, accuracy of the co-registration method was determined by measurement of the residual displacement in phantom lesions by two independent observers.ResultsMean displacements for a superficial and deep liver lesion were comparable after manual and semiautomatic co-registration: 2.4 and 2.0 mm versus 2.0 and 2.5 mm, respectively. Both methods were significantly better than automatic co-registration: 5.9 and 5.2 mm residual displacement (p < 0.001; p < 0.01). The accuracy of manual point registration was higher than that of plane registration, the latter being heavily dependent on accurate matching of axial CT and US images by the operator. Automatic reference point selection resulted in significantly lower registration accuracy compared to manual point selection despite lower root-mean-square deviation (RMSD) values.ConclusionThe accuracy of manual and semiautomatic co-registration is better than that of automatic co-registration. For manual co-registration using a plane, choosing the correct plane orientation is an essential first step in the registration process. Automatic reference point selection based on RMSD values is error-prone.

  18. Schostakowitsch. Orchesterlieder (Vol. 2), Neeme Järvi / Werner Pfister

    Index Scriptorium Estoniae

    Pfister, Werner

    1996-01-01

    Uuest heliplaadist "Schostakowitsch. Orchesterlieder (Vol. 2): Sechs Romanzen op. 21, Sechs Gedichte op. 143a, Suite auf Verse von Michelangelo Buonarroti op. 145a. Göteborger Sinfoniker, Neeme Järvi". DG CD 447 085-2 (WD: 71'06") DDD

  19. Automated extraction of DNA from biological stains on fabric from crime cases. A comparison of a manual and three automated methods.

    Science.gov (United States)

    Stangegaard, Michael; Hjort, Benjamin B; Hansen, Thomas N; Hoflund, Anders; Mogensen, Helle S; Hansen, Anders J; Morling, Niels

    2013-05-01

    The presence of PCR inhibitors in extracted DNA may interfere with the subsequent quantification and short tandem repeat (STR) reactions used in forensic genetic DNA typing. DNA extraction from fabric for forensic genetic purposes may be challenging due to the occasional presence of PCR inhibitors that may be co-extracted with the DNA. Using 120 forensic trace evidence samples consisting of various types of fabric, we compared three automated DNA extraction methods based on magnetic beads (PrepFiler Express Forensic DNA Extraction Kit on an AutoMate Express, QIAsyphony DNA Investigator kit either with the sample pre-treatment recommended by Qiagen or an in-house optimized sample pre-treatment on a QIAsymphony SP) and one manual method (Chelex) with the aim of reducing the amount of PCR inhibitors in the DNA extracts and increasing the proportion of reportable STR-profiles. A total of 480 samples were processed. The highest DNA recovery was obtained with the PrepFiler Express kit on an AutoMate Express while the lowest DNA recovery was obtained using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen. Extraction using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen resulted in the lowest percentage of PCR inhibition (0%) while extraction using manual Chelex resulted in the highest percentage of PCR inhibition (51%). The largest number of reportable STR-profiles was obtained with DNA from samples extracted with the PrepFiler Express kit (75%) while the lowest number was obtained with DNA from samples extracted using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen (41%). Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  20. Operation and maintenance manual for data acquisition system of MIDAS

    International Nuclear Information System (INIS)

    Lee, D. Y.; Park, W. M.; Kim, J. T.; Euh, D. J.

    2001-09-01

    This report describes an operation and maintenance manual of the data acquisition system and the data processing system for the DVI performance evaluation facility, MIDAS. The data acquisition system is implemented with VXI based system of Kinetic Systems TM , and the data processing PC. This report presents the configuration method and operation procedure for the operator. The modification procedure and method for functional extension and performance modification are also included for the future demand

  1. Study of developing nuclear fabrication facility's integrated emergency response manual

    International Nuclear Information System (INIS)

    Kim, Taeh Yeong; Cho, Nam Chan; Han, Seung Hoon; Moon, Jong Han; Lee, Jin Hang; Min, Guem Young; Han, Ji Ah

    2016-01-01

    Public begin to pay attention to emergency management. Thus, public's consensus on having high level of emergency management system up to advanced country's is reached. In this social atmosphere, manual is considered as key factor to prevent accident or secure business continuity. Therefore, we first define possible crisis at KEPCO Nuclear Fuel (hereinafter KNF) and also make a 'Reaction List' for each crisis situation at the view of information-design. To achieve it, we analyze several country's crisis response manual and then derive component, indicate duties and roles at the information-design point of view. From this, we suggested guideline to make 'Integrated emergency response manual(IERM)'. The manual we used before have following few problems; difficult to applicate at the site, difficult to deliver information. To complement these problems, we searched manual elements from the view of information-design. As a result, we develop administrative manual. Although, this manual could be thought as fragmentary manual because it confined specific several agency/organization and disaster type

  2. Hanford Waste Vitrification Plant technical manual

    Energy Technology Data Exchange (ETDEWEB)

    Larson, D.E. [ed.; Watrous, R.A.; Kruger, O.L. [and others

    1996-03-01

    A key element of the Hanford waste management strategy is the construction of a new facility, the Hanford Waste Vitrification Plant (HWVP), to vitrify existing and future liquid high-level waste produced by defense activities at the Hanford Site. The HWVP mission is to vitrify pretreated waste in borosilicate glass, cast the glass into stainless steel canisters, and store the canisters at the Hanford Site until they are shipped to a federal geological repository. The HWVP Technical Manual (Manual) documents the technical bases of the current HWVP process and provides a physical description of the related equipment and the plant. The immediate purpose of the document is to provide the technical bases for preparation of project baseline documents that will be used to direct the Title 1 and Title 2 design by the A/E, Fluor. The content of the Manual is organized in the following manner. Chapter 1.0 contains the background and context within which the HWVP was designed. Chapter 2.0 describes the site, plant, equipment and supporting services and provides the context for application of the process information in the Manual. Chapter 3.0 provides plant feed and product requirements, which are primary process bases for plant operation. Chapter 4.0 summarizes the technology for each plant process. Chapter 5.0 describes the engineering principles for designing major types of HWVP equipment. Chapter 6.0 describes the general safety aspects of the plant and process to assist in safe and prudent facility operation. Chapter 7.0 includes a description of the waste form qualification program and data. Chapter 8.0 indicates the current status of quality assurance requirements for the Manual. The Appendices provide data that are too extensive to be placed in the main text, such as extensive tables and sets of figures. The Manual is a revision of the 1987 version.

  3. Hanford Waste Vitrification Plant technical manual

    International Nuclear Information System (INIS)

    Larson, D.E.; Watrous, R.A.; Kruger, O.L.

    1996-03-01

    A key element of the Hanford waste management strategy is the construction of a new facility, the Hanford Waste Vitrification Plant (HWVP), to vitrify existing and future liquid high-level waste produced by defense activities at the Hanford Site. The HWVP mission is to vitrify pretreated waste in borosilicate glass, cast the glass into stainless steel canisters, and store the canisters at the Hanford Site until they are shipped to a federal geological repository. The HWVP Technical Manual (Manual) documents the technical bases of the current HWVP process and provides a physical description of the related equipment and the plant. The immediate purpose of the document is to provide the technical bases for preparation of project baseline documents that will be used to direct the Title 1 and Title 2 design by the A/E, Fluor. The content of the Manual is organized in the following manner. Chapter 1.0 contains the background and context within which the HWVP was designed. Chapter 2.0 describes the site, plant, equipment and supporting services and provides the context for application of the process information in the Manual. Chapter 3.0 provides plant feed and product requirements, which are primary process bases for plant operation. Chapter 4.0 summarizes the technology for each plant process. Chapter 5.0 describes the engineering principles for designing major types of HWVP equipment. Chapter 6.0 describes the general safety aspects of the plant and process to assist in safe and prudent facility operation. Chapter 7.0 includes a description of the waste form qualification program and data. Chapter 8.0 indicates the current status of quality assurance requirements for the Manual. The Appendices provide data that are too extensive to be placed in the main text, such as extensive tables and sets of figures. The Manual is a revision of the 1987 version

  4. Oregon School Bond Manual. Fourth Edition.

    Science.gov (United States)

    Oregon State Dept. of Education, Salem.

    The manual is intended to guide attorneys and officials of school districts in the issuance and sale of school district bonds. Purchasers of school district bonds rely on the recommendations of accredited bond attorneys who render opinions concerning the validity and legality of bond issues offered for sale. This manual is designed to assist in…

  5. Water Quality & Pollutant Source Monitoring: Field and Laboratory Procedures. Training Manual.

    Science.gov (United States)

    Office of Water Program Operations (EPA), Cincinnati, OH. National Training and Operational Technology Center.

    This training manual presents material on techniques and instrumentation used to develop data in field monitoring programs and related laboratory operations concerned with water quality and pollution monitoring. Topics include: collection and handling of samples; bacteriological, biological, and chemical field and laboratory methods; field…

  6. Manual muscle testing: a method of measuring extremity muscle strength applied to critically ill patients.

    Science.gov (United States)

    Ciesla, Nancy; Dinglas, Victor; Fan, Eddy; Kho, Michelle; Kuramoto, Jill; Needham, Dale

    2011-04-12

    Survivors of acute respiratory distress syndrome (ARDS) and other causes of critical illness often have generalized weakness, reduced exercise tolerance, and persistent nerve and muscle impairments after hospital discharge. Using an explicit protocol with a structured approach to training and quality assurance of research staff, manual muscle testing (MMT) is a highly reliable method for assessing strength, using a standardized clinical examination, for patients following ARDS, and can be completed with mechanically ventilated patients who can tolerate sitting upright in bed and are able to follow two-step commands. (7, 8) This video demonstrates a protocol for MMT, which has been taught to ≥ 43 research staff who have performed >800 assessments on >280 ARDS survivors. Modifications for the bedridden patient are included. Each muscle is tested with specific techniques for positioning, stabilization, resistance, and palpation for each score of the 6-point ordinal Medical Research Council scale. Three upper and three lower extremity muscles are graded in this protocol: shoulder abduction, elbow flexion, wrist extension, hip flexion, knee extension, and ankle dorsiflexion. These muscles were chosen based on the standard approach for evaluating patients for ICU-acquired weakness used in prior publications. (1,2).

  7. Dynamic delivery of the National Transit Database Sampling Manual.

    Science.gov (United States)

    2013-02-01

    This project improves the National Transit Database (NTD) Sampling Manual and develops an Internet-based, WordPress-powered interactive Web tool to deliver the new NTD Sampling Manual dynamically. The new manual adds guidance and a tool for transit a...

  8. Nigerian Journal of Chemical Research 29 Vol. 15, 2010 ...

    African Journals Online (AJOL)

    Hp

    Nigerian Journal of Chemical Research. 29. Vol. 15, 2010. Antibacterial & Antifungal Studies On Some Coordination Compound Of Metals. With Ampicillin. Pranay Guru. Department of Engineering Chemistry, People's College of Research & Technology, Bhopal. (M. P.) India, email:pranayguru@rediffmail.com. ABSTRACT.

  9. African Journal of Biotechnology - Vol 12, No 21 (2013)

    African Journals Online (AJOL)

    African Journal of Biotechnology - Vol 12, No 21 (2013) ... Studies of the genetics of inheritance of stem rust resistance in bread wheat · EMAIL FREE .... Evaluation of the effect of ginger modified cassava starch as thickener in the formulation of ...

  10. Cross sections for atomic processes, vol. 2

    International Nuclear Information System (INIS)

    Takayanagi, Kazuo; Suzuki, Hiroshi; Otani, Shunsuke

    1977-09-01

    This data collection book contains the data on all processes involving hydrogen and helium isotopes, their ions, electrons and photons, collected systematically and comprehensively, and is compiled subsequently to Vol. 1 as one of the works of the data collection study group in the Institute of Plasma Physics, Nagoya University, Japan. The items of the contents will include energy level, multiplicately excited state, radiation process, electron collision, ionic collision, recombination, collision of neutral atoms, colliding process involving molecules, and other processes. However, the first edition this time contains energy level, radiation process, electron collision and ionic collision, and the data on remaining items are now under collection. Though some criticisms have been heard about Vol. 1, the authors consider that such comprehensive collection based on systematic classification is the foundation of making a generalized data bank expected to become necessary in future. Thus the data collection book includes all relevant processes, and records the experimental data and theoretically calculated results in principle without modification by selecting them systematically. This year, investigation on data evaluation is taken up also as one of the tasks of the study group. (Wakatsuki, Y.)

  11. Comparison of Inoculation with the InoqulA and WASP Automated Systems with Manual Inoculation

    Science.gov (United States)

    Croxatto, Antony; Dijkstra, Klaas; Prod'hom, Guy

    2015-01-01

    The quality of sample inoculation is critical for achieving an optimal yield of discrete colonies in both monomicrobial and polymicrobial samples to perform identification and antibiotic susceptibility testing. Consequently, we compared the performance between the InoqulA (BD Kiestra), the WASP (Copan), and manual inoculation methods. Defined mono- and polymicrobial samples of 4 bacterial species and cloudy urine specimens were inoculated on chromogenic agar by the InoqulA, the WASP, and manual methods. Images taken with ImagA (BD Kiestra) were analyzed with the VisionLab version 3.43 image analysis software to assess the quality of growth and to prevent subjective interpretation of the data. A 3- to 10-fold higher yield of discrete colonies was observed following automated inoculation with both the InoqulA and WASP systems than that with manual inoculation. The difference in performance between automated and manual inoculation was mainly observed at concentrations of >106 bacteria/ml. Inoculation with the InoqulA system allowed us to obtain significantly more discrete colonies than the WASP system at concentrations of >107 bacteria/ml. However, the level of difference observed was bacterial species dependent. Discrete colonies of bacteria present in 100- to 1,000-fold lower concentrations than the most concentrated populations in defined polymicrobial samples were not reproducibly recovered, even with the automated systems. The analysis of cloudy urine specimens showed that InoqulA inoculation provided a statistically significantly higher number of discrete colonies than that with WASP and manual inoculation. Consequently, the automated InoqulA inoculation greatly decreased the requirement for bacterial subculture and thus resulted in a significant reduction in the time to results, laboratory workload, and laboratory costs. PMID:25972424

  12. Hoisting and rigging manual: Uncontrolled document

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-05-01

    This document is a draft copy of a Hoisting and Rigging Manual for the Department of Energy. The manual is divided into ten chapters. The chapter titles follow: terminology and definitions; operator training and qualification; overhead and gantry cranes; mobile cranes; forklift trucks; hoists; hooks; wire rope, slings, and rigging accessories; construction hoisting and rigging equipment requirements; references.

  13. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques.

    Science.gov (United States)

    Engesæter, Ingvild Øvstebø; Laborie, Lene Bjerke; Lehmann, Trude Gundersen; Sera, Francesco; Fevang, Jonas; Pedersen, Douglas; Morcuende, José; Lie, Stein Atle; Engesæter, Lars Birger; Rosendahl, Karen

    2012-07-01

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Tönnis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good.

  14. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Engesaeter, Ingvild Oevsteboe [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Haukeland University Hospital, The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Bergen (Norway); Laborie, Lene Bjerke; Rosendahl, Karen [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Lehmann, Trude Gundersen; Fevang, Jonas; Engesaeter, Lars Birger [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Sera, Francesco [University College London Institute of Child Health, Medical Research Council Centre of Epidemiology for Child Health, London (United Kingdom); Pedersen, Douglas; Morcuende, Jose [University of Iowa Hospital and Clinics, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States); Lie, Stein Atle [Uni Health, Uni Research, Bergen (Norway)

    2012-07-15

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Toennis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good. (orig.)

  15. Requirements to be met by the operation manual

    International Nuclear Information System (INIS)

    1981-03-01

    The rule applies to the contents and the lay-out of the operating manual for stationary nuclear power plants. The draft contains: 1. General requirement to be met by the contents of the operating manual. The operating manual to be arranged in 4 parts (part 1: internal rules and regulations; part 2: operation overall plant; part 3: incidents; part 4: operation systems). Safety specifications to be included in the manual, the exemption being the system of technical documentation. 2. General requirements to be met by the lay-out of the operating manual. Comprehensibility; legibility; structure and subdivisions; arrangement of the instructions and design of the manuals cover. 3. Requirements to be met by part 1. Defining the various internal rules and regulations (personnel management); rules and regulations concerning inspections and shift work; maintenance and repair; radiation protection; guard duty and admission; alarm; fire protection; first aid. 4. Requirements to be met by part 2. Provisions and operational limitations; limit values important from the point of view of safety; normal operation; anomalous operation; in-service inspections. 6. Requirements to be met by part 3. 7. Annex: Rules, regulations and stipulations mentioned in the rule draft. (orig.)

  16. User manual for version 4.3 of the Tripoli-4 Monte-Carlo method particle transport computer code

    International Nuclear Information System (INIS)

    Both, J.P.; Mazzolo, A.; Peneliau, Y.; Petit, O.; Roesslinger, B.

    2003-01-01

    This manual relates to Version 4.3 TRIPOLI-4 code. TRIPOLI-4 is a computer code simulating the transport of neutrons, photons, electrons and positrons. It can be used for radiation shielding calculations (long-distance propagation with flux attenuation in non-multiplying media) and neutronic calculations (fissile medium, criticality or sub-criticality basis). This makes it possible to calculate k eff (for criticality), flux, currents, reaction rates and multi-group cross-sections. TRIPOLI-4 is a three-dimensional code that uses the Monte-Carlo method. It allows for point-wise description in terms of energy of cross-sections and multi-group homogenized cross-sections and features two modes of geometrical representation: surface and combinatorial. The code uses cross-section libraries in ENDF/B format (such as JEF2-2, ENDF/B-VI and JENDL) for point-wise description cross-sections in APOTRIM format (from the APOLLO2 code) or a format specific to TRIPOLI-4 for multi-group description. (authors)

  17. Netbooks The Missing Manual

    CERN Document Server

    Biersdorfer, J

    2009-01-01

    Netbooks are the hot new thing in PCs -- small, inexpensive laptops designed for web browsing, email, and working with web-based programs. But chances are you don't know how to choose a netbook, let alone use one. Not to worry: with this Missing Manual, you'll learn which netbook is right for you and how to set it up and use it for everything from spreadsheets for work to hobbies like gaming and photo sharing. Netbooks: The Missing Manual provides easy-to-follow instructions and lots of advice to help you: Learn the basics for using a Windows- or Linux-based netbookConnect speakers, printe

  18. Design and development of solar power-assisted manual/electric wheelchair.

    Science.gov (United States)

    Chien, Chi-Sheng; Huang, Tung-Yung; Liao, Tze-Yuan; Kuo, Tsung-Yuan; Lee, Tzer-Min

    2014-01-01

    Wheelchairs are an essential assistive device for many individuals with injury or disability. Manual wheelchairs provide a relatively low-cost solution to the mobility needs of such individuals. Furthermore, they provide an effective means of improving the user's cardiopulmonary function and upper-limb muscle strength. However, manual wheelchairs have a loss gross mechanical efficiency, and thus the risk of user fatigue and upper-limb injury is increased. Electric-powered wheelchairs reduce the risk of injury and provide a more convenient means of transportation. However, they have a large physical size and are relatively expensive. Accordingly, the present study utilizes a quality function deployment method to develop a wheelchair with a user-selectable manual/electric propulsion mode and an auxiliary solar power supply system. The auxiliary solar power supply increased the travel range of the wheelchair by approximately 26% compared with that of a wheelchair powered by battery alone. Moreover, the wheelchair has a modular design and can be disassembled and folded for ease of transportation or storage. Overall, the present results suggest that the proposed wheelchair provides an effective and convenient means of meeting the mobility needs of individuals with mobility difficulties.

  19. Radiological control technician: Training program management manual

    International Nuclear Information System (INIS)

    1992-10-01

    This manual defines and describes the DOE Radiological Control Technician Core Training Program qualification and training process, material development requirements, standards and policies, and administration. The manual applies to Radiological Control Technician Training Programs at all DOE contractor sites

  20. An analysis of the process and results of manual geocode correction

    Science.gov (United States)

    McDonald, Yolanda J.; Schwind, Michael; Goldberg, Daniel W.; Lampley, Amanda; Wheeler, Cosette M.

    2018-01-01

    Geocoding is the science and process of assigning geographical coordinates (i.e. latitude, longitude) to a postal address. The quality of the geocode can vary dramatically depending on several variables, including incorrect input address data, missing address components, and spelling mistakes. A dataset with a considerable number of geocoding inaccuracies can potentially result in an imprecise analysis and invalid conclusions. There has been little quantitative analysis of the amount of effort (i.e. time) to perform geocoding correction, and how such correction could improve geocode quality type. This study used a low-cost and easy to implement method to improve geocode quality type of an input database (i.e. addresses to be matched) through the processes of manual geocode intervention, and it assessed the amount of effort to manually correct inaccurate geocodes, reported the resulting match rate improvement between the original and the corrected geocodes, and documented the corresponding spatial shift by geocode quality type resulting from the corrections. Findings demonstrated that manual intervention of geocoding resulted in a 90% improvement of geocode quality type, took 42 hours to process, and the spatial shift ranged from 0.02 to 151,368 m. This study provides evidence to inform research teams considering the application of manual geocoding intervention that it is a low-cost and relatively easy process to execute. PMID:28555477