  1. Valid methods: the quality assurance of test method development, validation, approval, and transfer for veterinary testing laboratories.

    Science.gov (United States)

    Wiegers, Ann L

    2003-07-01

    Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.

  2. An assessment of the validity of inelastic design analysis methods by comparisons of predictions with test results

    International Nuclear Information System (INIS)

    Corum, J.M.; Clinard, J.A.; Sartory, W.K.

    1976-01-01

    The use of computer programs that employ relatively complex constitutive theories and analysis procedures to perform inelastic design calculations on fast reactor system components introduces questions of validation and acceptance of the analysis results. We may ask ourselves, ''How valid are the answers.'' These questions, in turn, involve the concepts of verification of computer programs as well as qualification of the computer programs and of the underlying constitutive theories and analysis procedures. This paper addresses the latter - the qualification of the analysis methods for inelastic design calculations. Some of the work underway in the United States to provide the necessary information to evaluate inelastic analysis methods and computer programs is described, and typical comparisons of analysis predictions with inelastic structural test results are presented. It is emphasized throughout that rather than asking ourselves how valid, or correct, are the analytical predictions, we might more properly question whether or not the combination of the predictions and the associated high-temperature design criteria leads to an acceptable level of structural integrity. It is believed that in this context the analysis predictions are generally valid, even though exact correlations between predictions and actual behavior are not obtained and cannot be expected. Final judgment, however, must be reserved for the design analyst in each specific case. (author)

  3. Method validation in plasma source optical emission spectroscopy (ICP-OES) - From samples to results

    International Nuclear Information System (INIS)

    Pilon, Fabien; Vielle, Karine; Birolleau, Jean-Claude; Vigneau, Olivier; Labet, Alexandre; Arnal, Nadege; Adam, Christelle; Camilleri, Virginie; Amiel, Jeanine; Granier, Guy; Faure, Joel; Arnaud, Regine; Beres, Andre; Blanchard, Jean-Marc; Boyer-Deslys, Valerie; Broudic, Veronique; Marques, Caroline; Augeray, Celine; Bellefleur, Alexandre; Bienvenu, Philippe; Delteil, Nicole; Boulet, Beatrice; Bourgarit, David; Brennetot, Rene; Fichet, Pascal; Celier, Magali; Chevillotte, Rene; Klelifa, Aline; Fuchs, Gilbert; Le Coq, Gilles; Mermet, Jean-Michel

    2017-01-01

    Even though ICP-OES (Inductively Coupled Plasma - Optical Emission Spectroscopy) is now a routine analysis technique, requirements for measuring processes impose a complete control and mastering of the operating process and of the associated quality management system. The aim of this (collective) book is to guide the analyst during all the measurement validation procedure and to help him to guarantee the mastering of its different steps: administrative and physical management of samples in the laboratory, preparation and treatment of the samples before measuring, qualification and monitoring of the apparatus, instrument setting and calibration strategy, exploitation of results in terms of accuracy, reliability, data covariance (with the practical determination of the accuracy profile). The most recent terminology is used in the book, and numerous examples and illustrations are given in order to a better understanding and to help the elaboration of method validation documents

  4. Practical procedure for method validation in INAA- A tutorial

    International Nuclear Information System (INIS)

    Petroni, Robson; Moreira, Edson G.

    2015-01-01

    This paper describes the procedure employed by the Neutron Activation Laboratory at the Nuclear and Energy Research Institute (LAN, IPEN - CNEN/SP) for validation of Instrumental Neutron Activation Analysis (INAA) methods. According to recommendations of ISO/IEC 17025 the method performance characteristics (limit of detection, limit of quantification, trueness, repeatability, intermediate precision, reproducibility, selectivity, linearity and uncertainties budget) were outline in an easy, fast and convenient way. The paper presents step by step how to calculate the required method performance characteristics in a process of method validation, what are the procedures, adopted strategies and acceptance criteria for the results, that is, how to make a method validation in INAA. In order to exemplify the methodology applied, obtained results for the method validation of mass fraction determination of Co, Cr, Fe, Rb, Se and Zn in biological matrix samples, using an internal reference material of mussel tissue were presented. It was concluded that the methodology applied for validation of INAA methods is suitable, meeting all the requirements of ISO/IEC 17025, and thereby, generating satisfactory results for the studies carried at LAN, IPEN - CNEN/SP. (author)

  5. Practical procedure for method validation in INAA- A tutorial

    Energy Technology Data Exchange (ETDEWEB)

    Petroni, Robson; Moreira, Edson G., E-mail: robsonpetroni@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    This paper describes the procedure employed by the Neutron Activation Laboratory at the Nuclear and Energy Research Institute (LAN, IPEN - CNEN/SP) for validation of Instrumental Neutron Activation Analysis (INAA) methods. According to recommendations of ISO/IEC 17025 the method performance characteristics (limit of detection, limit of quantification, trueness, repeatability, intermediate precision, reproducibility, selectivity, linearity and uncertainties budget) were outline in an easy, fast and convenient way. The paper presents step by step how to calculate the required method performance characteristics in a process of method validation, what are the procedures, adopted strategies and acceptance criteria for the results, that is, how to make a method validation in INAA. In order to exemplify the methodology applied, obtained results for the method validation of mass fraction determination of Co, Cr, Fe, Rb, Se and Zn in biological matrix samples, using an internal reference material of mussel tissue were presented. It was concluded that the methodology applied for validation of INAA methods is suitable, meeting all the requirements of ISO/IEC 17025, and thereby, generating satisfactory results for the studies carried at LAN, IPEN - CNEN/SP. (author)

  6. Validation of NAA Method for Urban Particulate Matter

    International Nuclear Information System (INIS)

    Woro Yatu Niken Syahfitri; Muhayatun; Diah Dwiana Lestiani; Natalia Adventini

    2009-01-01

    Nuclear analytical techniques have been applied in many countries for determination of environmental pollutant. Method of NAA (neutron activation analysis) representing one of nuclear analytical technique of that has low detection limits, high specificity, high precision, and accuracy for large majority of naturally occurring elements, and ability of non-destructive and simultaneous determination of multi-elemental, and can handle small sample size (< 1 mg). To ensure quality and reliability of the method, validation are needed to be done. A standard reference material, SRM NIST 1648 Urban Particulate Matter, has been used to validate NAA method. Accuracy and precision test were used as validation parameters. Particulate matter were validated for 18 elements: Ti, I, V, Br, Mn, Na, K, Cl, Cu, Al, As, Fe, Co, Zn, Ag, La, Cr, and Sm,. The result showed that the percent relative standard deviation of the measured elemental concentrations are found to be within ranged from 2 to 14,8% for most of the elements analyzed whereas Hor rat value in range 0,3-1,3. Accuracy test results showed that relative bias ranged from -11,1 to 3,6%. Based on validation results, it can be stated that NAA method is reliable for characterization particulate matter and other similar matrix samples to support air quality monitoring. (author)

  7. Validation of method in instrumental NAA for food products sample

    International Nuclear Information System (INIS)

    Alfian; Siti Suprapti; Setyo Purwanto

    2010-01-01

    NAA is a method of testing that has not been standardized. To affirm and confirm that this method is valid. it must be done validation of the method with various sample standard reference materials. In this work. the validation is carried for food product samples using NIST SRM 1567a (wheat flour) and NIST SRM 1568a (rice flour). The results show that the validation method for testing nine elements (Al, K, Mg, Mn, Na, Ca, Fe, Se and Zn) in SRM 1567a and eight elements (Al, K, Mg, Mn, Na, Ca, Se and Zn ) in SRM 1568a pass the test of accuracy and precision. It can be conclude that this method has power to give valid result in determination element of the food products samples. (author)

  8. The Validation of NAA Method Used as Test Method in Serpong NAA Laboratory

    International Nuclear Information System (INIS)

    Rina-Mulyaningsih, Th.

    2004-01-01

    The Validation Of NAA Method Used As Test Method In Serpong NAA Laboratory. NAA Method is a non standard testing method. The testing laboratory shall validate its using method to ensure and confirm that it is suitable with application. The validation of NAA methods have been done with the parameters of accuracy, precision, repeatability and selectivity. The NIST 1573a Tomato Leaves, NIES 10C Rice flour unpolished and standard elements were used in this testing program. The result of testing with NIST 1573a showed that the elements of Na, Zn, Al and Mn are met from acceptance criteria of accuracy and precision, whereas Co is rejected. The result of testing with NIES 10C showed that Na and Zn elements are met from acceptance criteria of accuracy and precision, but Mn element is rejected. The result of selectivity test showed that the value of quantity is between 0.1-2.5 μg, depend on the elements. (author)

  9. An intercomparison of a large ensemble of statistical downscaling methods for Europe: Overall results from the VALUE perfect predictor cross-validation experiment

    Science.gov (United States)

    Gutiérrez, Jose Manuel; Maraun, Douglas; Widmann, Martin; Huth, Radan; Hertig, Elke; Benestad, Rasmus; Roessler, Ole; Wibig, Joanna; Wilcke, Renate; Kotlarski, Sven

    2016-04-01

    VALUE is an open European network to validate and compare downscaling methods for climate change research (http://www.value-cost.eu). A key deliverable of VALUE is the development of a systematic validation framework to enable the assessment and comparison of both dynamical and statistical downscaling methods. This framework is based on a user-focused validation tree, guiding the selection of relevant validation indices and performance measures for different aspects of the validation (marginal, temporal, spatial, multi-variable). Moreover, several experiments have been designed to isolate specific points in the downscaling procedure where problems may occur (assessment of intrinsic performance, effect of errors inherited from the global models, effect of non-stationarity, etc.). The list of downscaling experiments includes 1) cross-validation with perfect predictors, 2) GCM predictors -aligned with EURO-CORDEX experiment- and 3) pseudo reality predictors (see Maraun et al. 2015, Earth's Future, 3, doi:10.1002/2014EF000259, for more details). The results of these experiments are gathered, validated and publicly distributed through the VALUE validation portal, allowing for a comprehensive community-open downscaling intercomparison study. In this contribution we describe the overall results from Experiment 1), consisting of a European wide 5-fold cross-validation (with consecutive 6-year periods from 1979 to 2008) using predictors from ERA-Interim to downscale precipitation and temperatures (minimum and maximum) over a set of 86 ECA&D stations representative of the main geographical and climatic regions in Europe. As a result of the open call for contribution to this experiment (closed in Dec. 2015), over 40 methods representative of the main approaches (MOS and Perfect Prognosis, PP) and techniques (linear scaling, quantile mapping, analogs, weather typing, linear and generalized regression, weather generators, etc.) were submitted, including information both data

  10. Validation of the Rotation Ratios Method

    International Nuclear Information System (INIS)

    Foss, O.A.; Klaksvik, J.; Benum, P.; Anda, S.

    2007-01-01

    Background: The rotation ratios method describes rotations between pairs of sequential pelvic radiographs. The method seems promising but has not been validated. Purpose: To validate the accuracy of the rotation ratios method. Material and Methods: Known pelvic rotations between 165 radiographs obtained from five skeletal pelvises in an experimental material were compared with the corresponding calculated rotations to describe the accuracy of the method. The results from a clinical material of 262 pelvic radiographs from 46 patients defined the ranges of rotational differences compared. Repeated analyses, both on the experimental and the clinical material, were performed using the selected reference points to describe the robustness and the repeatability of the method. Results: The reference points were easy to identify and barely influenced by pelvic rotations. The mean differences between calculated and real pelvic rotations were 0.0 deg (SD 0.6) for vertical rotations and 0.1 deg (SD 0.7) for transversal rotations in the experimental material. The intra- and interobserver repeatability of the method was good. Conclusion: The accuracy of the method was reasonably high, and the method may prove to be clinically useful

  11. Validation of Land Cover Products Using Reliability Evaluation Methods

    Directory of Open Access Journals (Sweden)

    Wenzhong Shi

    2015-06-01

    Full Text Available Validation of land cover products is a fundamental task prior to data applications. Current validation schemes and methods are, however, suited only for assessing classification accuracy and disregard the reliability of land cover products. The reliability evaluation of land cover products should be undertaken to provide reliable land cover information. In addition, the lack of high-quality reference data often constrains validation and affects the reliability results of land cover products. This study proposes a validation schema to evaluate the reliability of land cover products, including two methods, namely, result reliability evaluation and process reliability evaluation. Result reliability evaluation computes the reliability of land cover products using seven reliability indicators. Process reliability evaluation analyzes the reliability propagation in the data production process to obtain the reliability of land cover products. Fuzzy fault tree analysis is introduced and improved in the reliability analysis of a data production process. Research results show that the proposed reliability evaluation scheme is reasonable and can be applied to validate land cover products. Through the analysis of the seven indicators of result reliability evaluation, more information on land cover can be obtained for strategic decision-making and planning, compared with traditional accuracy assessment methods. Process reliability evaluation without the need for reference data can facilitate the validation and reflect the change trends of reliabilities to some extent.

  12. Method validation in pharmaceutical analysis: from theory to practical optimization

    Directory of Open Access Journals (Sweden)

    Jaqueline Kaleian Eserian

    2015-01-01

    Full Text Available The validation of analytical methods is required to obtain high-quality data. For the pharmaceutical industry, method validation is crucial to ensure the product quality as regards both therapeutic efficacy and patient safety. The most critical step in validating a method is to establish a protocol containing well-defined procedures and criteria. A well planned and organized protocol, such as the one proposed in this paper, results in a rapid and concise method validation procedure for quantitative high performance liquid chromatography (HPLC analysis.   Type: Commentary

  13. Results of a survey on accident and safety analysis codes, benchmarks, verification and validation methods

    International Nuclear Information System (INIS)

    Lee, A.G.; Wilkin, G.B.

    1996-03-01

    During the 'Workshop on R and D needs' at the 3rd Meeting of the International Group on Research Reactors (IGORR-III), the participants agreed that it would be useful to compile a survey of the computer codes and nuclear data libraries used in accident and safety analyses for research reactors and the methods various organizations use to verify and validate their codes and libraries. Five organizations, Atomic Energy of Canada Limited (AECL, Canada), China Institute of Atomic Energy (CIAE, People's Republic of China), Japan Atomic Energy Research Institute (JAERI, Japan), Oak Ridge National Laboratories (ORNL, USA), and Siemens (Germany) responded to the survey. The results of the survey are compiled in this report. (author) 36 refs., 3 tabs

  14. Method Validation Procedure in Gamma Spectroscopy Laboratory

    International Nuclear Information System (INIS)

    El Samad, O.; Baydoun, R.

    2008-01-01

    The present work describes the methodology followed for the application of ISO 17025 standards in gamma spectroscopy laboratory at the Lebanese Atomic Energy Commission including the management and technical requirements. A set of documents, written procedures and records were prepared to achieve the management part. The technical requirements, internal method validation was applied through the estimation of trueness, repeatability , minimum detectable activity and combined uncertainty, participation in IAEA proficiency tests assure the external method validation, specially that the gamma spectroscopy lab is a member of ALMERA network (Analytical Laboratories for the Measurements of Environmental Radioactivity). Some of these results are presented in this paper. (author)

  15. Analytical models approximating individual processes: a validation method.

    Science.gov (United States)

    Favier, C; Degallier, N; Menkès, C E

    2010-12-01

    Upscaling population models from fine to coarse resolutions, in space, time and/or level of description, allows the derivation of fast and tractable models based on a thorough knowledge of individual processes. The validity of such approximations is generally tested only on a limited range of parameter sets. A more general validation test, over a range of parameters, is proposed; this would estimate the error induced by the approximation, using the original model's stochastic variability as a reference. This method is illustrated by three examples taken from the field of epidemics transmitted by vectors that bite in a temporally cyclical pattern, that illustrate the use of the method: to estimate if an approximation over- or under-fits the original model; to invalidate an approximation; to rank possible approximations for their qualities. As a result, the application of the validation method to this field emphasizes the need to account for the vectors' biology in epidemic prediction models and to validate these against finer scale models. Copyright © 2010 Elsevier Inc. All rights reserved.

  16. The Method of Manufactured Universes for validating uncertainty quantification methods

    KAUST Repository

    Stripling, H.F.

    2011-09-01

    The Method of Manufactured Universes is presented as a validation framework for uncertainty quantification (UQ) methodologies and as a tool for exploring the effects of statistical and modeling assumptions embedded in these methods. The framework calls for a manufactured reality from which experimental data are created (possibly with experimental error), an imperfect model (with uncertain inputs) from which simulation results are created (possibly with numerical error), the application of a system for quantifying uncertainties in model predictions, and an assessment of how accurately those uncertainties are quantified. The application presented in this paper manufactures a particle-transport universe, models it using diffusion theory with uncertain material parameters, and applies both Gaussian process and Bayesian MARS algorithms to make quantitative predictions about new experiments within the manufactured reality. The results of this preliminary study indicate that, even in a simple problem, the improper application of a specific UQ method or unrealized effects of a modeling assumption may produce inaccurate predictions. We conclude that the validation framework presented in this paper is a powerful and flexible tool for the investigation and understanding of UQ methodologies. © 2011 Elsevier Ltd. All rights reserved.

  17. Cross-Validation of Survival Bump Hunting by Recursive Peeling Methods.

    Science.gov (United States)

    Dazard, Jean-Eudes; Choe, Michael; LeBlanc, Michael; Rao, J Sunil

    2014-08-01

    We introduce a survival/risk bump hunting framework to build a bump hunting model with a possibly censored time-to-event type of response and to validate model estimates. First, we describe the use of adequate survival peeling criteria to build a survival/risk bump hunting model based on recursive peeling methods. Our method called "Patient Recursive Survival Peeling" is a rule-induction method that makes use of specific peeling criteria such as hazard ratio or log-rank statistics. Second, to validate our model estimates and improve survival prediction accuracy, we describe a resampling-based validation technique specifically designed for the joint task of decision rule making by recursive peeling (i.e. decision-box) and survival estimation. This alternative technique, called "combined" cross-validation is done by combining test samples over the cross-validation loops, a design allowing for bump hunting by recursive peeling in a survival setting. We provide empirical results showing the importance of cross-validation and replication.

  18. Testing and Validation of Computational Methods for Mass Spectrometry.

    Science.gov (United States)

    Gatto, Laurent; Hansen, Kasper D; Hoopmann, Michael R; Hermjakob, Henning; Kohlbacher, Oliver; Beyer, Andreas

    2016-03-04

    High-throughput methods based on mass spectrometry (proteomics, metabolomics, lipidomics, etc.) produce a wealth of data that cannot be analyzed without computational methods. The impact of the choice of method on the overall result of a biological study is often underappreciated, but different methods can result in very different biological findings. It is thus essential to evaluate and compare the correctness and relative performance of computational methods. The volume of the data as well as the complexity of the algorithms render unbiased comparisons challenging. This paper discusses some problems and challenges in testing and validation of computational methods. We discuss the different types of data (simulated and experimental validation data) as well as different metrics to compare methods. We also introduce a new public repository for mass spectrometric reference data sets ( http://compms.org/RefData ) that contains a collection of publicly available data sets for performance evaluation for a wide range of different methods.

  19. Method validation for chemical composition determination by electron microprobe with wavelength dispersive spectrometer

    Science.gov (United States)

    Herrera-Basurto, R.; Mercader-Trejo, F.; Muñoz-Madrigal, N.; Juárez-García, J. M.; Rodriguez-López, A.; Manzano-Ramírez, A.

    2016-07-01

    The main goal of method validation is to demonstrate that the method is suitable for its intended purpose. One of the advantages of analytical method validation is translated into a level of confidence about the measurement results reported to satisfy a specific objective. Elemental composition determination by wavelength dispersive spectrometer (WDS) microanalysis has been used over extremely wide areas, mainly in the field of materials science, impurity determinations in geological, biological and food samples. However, little information is reported about the validation of the applied methods. Herein, results of the in-house method validation for elemental composition determination by WDS are shown. SRM 482, a binary alloy Cu-Au of different compositions, was used during the validation protocol following the recommendations for method validation proposed by Eurachem. This paper can be taken as a reference for the evaluation of the validation parameters more frequently requested to get the accreditation under the requirements of the ISO/IEC 17025 standard: selectivity, limit of detection, linear interval, sensitivity, precision, trueness and uncertainty. A model for uncertainty estimation was proposed including systematic and random errors. In addition, parameters evaluated during the validation process were also considered as part of the uncertainty model.

  20. Validating the JobFit system functional assessment method

    Energy Technology Data Exchange (ETDEWEB)

    Jenny Legge; Robin Burgess-Limerick

    2007-05-15

    Workplace injuries are costing the Australian coal mining industry and its communities $410 Million a year. This ACARP study aims to meet those demands by developing a safe, reliable and valid pre-employment functional assessment tool. All JobFit System Pre-Employment Functional Assessments (PEFAs) consist of a musculoskeletal screen, balance test, aerobic fitness test and job-specific postural tolerances and material handling tasks. The results of each component are compared to the applicant's job demands and an overall PEFA score between 1 and 4 is given with 1 being the better score. The reliability study and validity study were conducted concurrently. The reliability study examined test-retest, intra-tester and inter-tester reliability of the JobFit System Functional Assessment Method. Overall, good to excellent reliability was found, which was sufficient to be used for comparison with injury data for determining the validity of the assessment. The overall assessment score and material handling tasks had the greatest reliability. The validity study compared the assessment results of 336 records from a Queensland underground and open cut coal mine with their injury records. A predictive relationship was found between PEFA score and the risk of a back/trunk/shoulder injury from manual handling. An association was also found between PEFA score of 1 and increased length of employment. Lower aerobic fitness test results had an inverse relationship with injury rates. The study found that underground workers, regardless of PEFA score, were more likely to have an injury when compared to other departments. No relationship was found between age and risk of injury. These results confirm the validity of the JobFit System Functional Assessment method.

  1. Comparing the Validity of Non-Invasive Methods in Measuring Thoracic Kyphosis and Lumbar Lordosis

    Directory of Open Access Journals (Sweden)

    Mohammad Yousefi

    2012-04-01

    Full Text Available Background: the purpose of this article is to study the validity of each of the non-invasive methods (flexible ruler, spinal mouse, and processing the image versus the one through-Ray radiation (the basic method and comparing them with each other.Materials and Methods: for evaluating the validity of each of these non-invasive methods, the thoracic Kyphosis and lumber Lordosis angle of 20 students of Birjand University (age mean and standard deviation: 26±2, weight: 72±2.5 kg, height: 169±5.5 cm through fours methods of flexible ruler, spinal mouse, and image processing and X-ray.Results: the results indicated that the validity of the methods including flexible ruler, spinal mouse, and image processing in measuring the thoracic Kyphosis and lumber Lordosis angle respectively have an adherence of 0.81, 0.87, 0.73, 0.76, 0.83, 0.89 (p>0.05. As a result, regarding the gained validity against the golden method of X-ray, it could be stated that the three mentioned non-invasive methods have adequate validity. In addition, the one-way analysis of variance test indicated that there existed a meaningful relationship between the three methods of measuring the thoracic Kyphosis and lumber Lordosis, and with respect to the Tukey’s test result, the image processing method is the most precise one.Conclusion as a result, this method could be used along with other non-invasive methods as a valid measuring method.

  2. Method validation for uranium content analysis using a potentiometer T-90

    International Nuclear Information System (INIS)

    Torowati; Ngatijo; Rahmiati

    2016-01-01

    An experimental method validation has been conducted for uranium content analysis using Potentiometer T-90. The method validation experiment was performed in the quality control laboratory of Experiment Fuel Element Installation, PTBBN - BATAN. The objective is to determine the level of precision and accuracy of analytical results for uranium analysis referring to the latest American Standard Test Method (ASTM) of ASTM C1267-11, which is a modified reference method by reducing of reagent consumption by 10% of the amount used by the original method. The ASTM C 1267-11 reference is a new ASTM as a substitute for the older ASTM namely ASTM C799, Vol.12.01, 2003. It is, therefore, necessary to validate the renewed method. The tool used for the analysis of uranium was potentiometer T-90 and the material used was standard uranium oxide powder CRM (Certificate Reference Material). Validation of the method was done by analyzing standard uranium powder by 7 times weighing and 7 times analysis. Analysis results were used to determine the level of accuracy, precision, Relative Standard Deviation (RSD) and Horwitz coefficient Variation and limit detection and quantitation. The average uranium obtained for this method validation is 84.36% with Standard Deviation (SD) of 0.12%, Relative Standard Deviation (RSD) 0.14% and 2/3 Horwitz coefficient Variation (CV Horwitz) 2.05%. The results show that RSD value is smaller than the value of (2/3) CV Horwitz, which means that this method has a high precision. The accuracy value obtained is 0.48%, and since the acceptance limit of high level of accuracy is when the accuracy value is <2.00%, this method is regarded as having a high degree of accuracy [1]. The limit of detection (LOD) and and the limit of quantitation (LOQ) are 0.0145 g/L and 0.0446 g/L respectively. It is concluded that the ASTM C 1267-11 reference method is valid for use. (author)

  3. Development and validation of analytical methods for dietary supplements

    International Nuclear Information System (INIS)

    Sullivan, Darryl; Crowley, Richard

    2006-01-01

    The expanding use of innovative botanical ingredients in dietary supplements and foods has resulted in a flurry of research aimed at the development and validation of analytical methods for accurate measurement of active ingredients. The pressing need for these methods is being met through an expansive collaborative initiative involving industry, government, and analytical organizations. This effort has resulted in the validation of several important assays as well as important advances in the method engineering procedures which have improved the efficiency of the process. The initiative has also allowed researchers to hurdle many of the barricades that have hindered accurate analysis such as the lack of reference standards and comparative data. As the availability for nutraceutical products continues to increase these methods will provide consumers and regulators with the scientific information needed to assure safety and dependable labeling

  4. OWL-based reasoning methods for validating archetypes.

    Science.gov (United States)

    Menárguez-Tortosa, Marcos; Fernández-Breis, Jesualdo Tomás

    2013-04-01

    Some modern Electronic Healthcare Record (EHR) architectures and standards are based on the dual model-based architecture, which defines two conceptual levels: reference model and archetype model. Such architectures represent EHR domain knowledge by means of archetypes, which are considered by many researchers to play a fundamental role for the achievement of semantic interoperability in healthcare. Consequently, formal methods for validating archetypes are necessary. In recent years, there has been an increasing interest in exploring how semantic web technologies in general, and ontologies in particular, can facilitate the representation and management of archetypes, including binding to terminologies, but no solution based on such technologies has been provided to date to validate archetypes. Our approach represents archetypes by means of OWL ontologies. This permits to combine the two levels of the dual model-based architecture in one modeling framework which can also integrate terminologies available in OWL format. The validation method consists of reasoning on those ontologies to find modeling errors in archetypes: incorrect restrictions over the reference model, non-conformant archetype specializations and inconsistent terminological bindings. The archetypes available in the repositories supported by the openEHR Foundation and the NHS Connecting for Health Program, which are the two largest publicly available ones, have been analyzed with our validation method. For such purpose, we have implemented a software tool called Archeck. Our results show that around 1/5 of archetype specializations contain modeling errors, the most common mistakes being related to coded terms and terminological bindings. The analysis of each repository reveals that different patterns of errors are found in both repositories. This result reinforces the need for making serious efforts in improving archetype design processes. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Experimental results and validation of a method to reconstruct forces on the ITER test blanket modules

    International Nuclear Information System (INIS)

    Zeile, Christian; Maione, Ivan A.

    2015-01-01

    Highlights: • An in operation force measurement system for the ITER EU HCPB TBM has been developed. • The force reconstruction methods are based on strain measurements on the attachment system. • An experimental setup and a corresponding mock-up have been built. • A set of test cases representing ITER relevant excitations has been used for validation. • The influence of modeling errors on the force reconstruction has been investigated. - Abstract: In order to reconstruct forces on the test blanket modules in ITER, two force reconstruction methods, the augmented Kalman filter and a model predictive controller, have been selected and developed to estimate the forces based on strain measurements on the attachment system. A dedicated experimental setup with a corresponding mock-up has been designed and built to validate these methods. A set of test cases has been defined to represent possible excitation of the system. It has been shown that the errors in the estimated forces mainly depend on the accuracy of the identified model used by the algorithms. Furthermore, it has been found that a minimum of 10 strain gauges is necessary to allow for a low error in the reconstructed forces.

  6. Fuzzy-logic based strategy for validation of multiplex methods: example with qualitative GMO assays.

    Science.gov (United States)

    Bellocchi, Gianni; Bertholet, Vincent; Hamels, Sandrine; Moens, W; Remacle, José; Van den Eede, Guy

    2010-02-01

    This paper illustrates the advantages that a fuzzy-based aggregation method could bring into the validation of a multiplex method for GMO detection (DualChip GMO kit, Eppendorf). Guidelines for validation of chemical, bio-chemical, pharmaceutical and genetic methods have been developed and ad hoc validation statistics are available and routinely used, for in-house and inter-laboratory testing, and decision-making. Fuzzy logic allows summarising the information obtained by independent validation statistics into one synthetic indicator of overall method performance. The microarray technology, introduced for simultaneous identification of multiple GMOs, poses specific validation issues (patterns of performance for a variety of GMOs at different concentrations). A fuzzy-based indicator for overall evaluation is illustrated in this paper, and applied to validation data for different genetically modified elements. Remarks were drawn on the analytical results. The fuzzy-logic based rules were shown to be applicable to improve interpretation of results and facilitate overall evaluation of the multiplex method.

  7. Validation for chromatographic and electrophoretic methods

    OpenAIRE

    Ribani, Marcelo; Bottoli, Carla Beatriz Grespan; Collins, Carol H.; Jardim, Isabel Cristina Sales Fontes; Melo, Lúcio Flávio Costa

    2004-01-01

    The validation of an analytical method is fundamental to implementing a quality control system in any analytical laboratory. As the separation techniques, GC, HPLC and CE, are often the principal tools used in such determinations, procedure validation is a necessity. The objective of this review is to describe the main aspects of validation in chromatographic and electrophoretic analysis, showing, in a general way, the similarities and differences between the guidelines established by the dif...

  8. Spacecraft early design validation using formal methods

    International Nuclear Information System (INIS)

    Bozzano, Marco; Cimatti, Alessandro; Katoen, Joost-Pieter; Katsaros, Panagiotis; Mokos, Konstantinos; Nguyen, Viet Yen; Noll, Thomas; Postma, Bart; Roveri, Marco

    2014-01-01

    The size and complexity of software in spacecraft is increasing exponentially, and this trend complicates its validation within the context of the overall spacecraft system. Current validation methods are labor-intensive as they rely on manual analysis, review and inspection. For future space missions, we developed – with challenging requirements from the European space industry – a novel modeling language and toolset for a (semi-)automated validation approach. Our modeling language is a dialect of AADL and enables engineers to express the system, the software, and their reliability aspects. The COMPASS toolset utilizes state-of-the-art model checking techniques, both qualitative and probabilistic, for the analysis of requirements related to functional correctness, safety, dependability and performance. Several pilot projects have been performed by industry, with two of them having focused on the system-level of a satellite platform in development. Our efforts resulted in a significant advancement of validating spacecraft designs from several perspectives, using a single integrated system model. The associated technology readiness level increased from level 1 (basic concepts and ideas) to early level 4 (laboratory-tested)

  9. Analytical difficulties facing today's regulatory laboratories: issues in method validation.

    Science.gov (United States)

    MacNeil, James D

    2012-08-01

    The challenges facing analytical laboratories today are not unlike those faced in the past, although both the degree of complexity and the rate of change have increased. Challenges such as development and maintenance of expertise, maintenance and up-dating of equipment, and the introduction of new test methods have always been familiar themes for analytical laboratories, but international guidelines for laboratories involved in the import and export testing of food require management of such changes in a context which includes quality assurance, accreditation, and method validation considerations. Decisions as to when a change in a method requires re-validation of the method or on the design of a validation scheme for a complex multi-residue method require a well-considered strategy, based on a current knowledge of international guidance documents and regulatory requirements, as well the laboratory's quality system requirements. Validation demonstrates that a method is 'fit for purpose', so the requirement for validation should be assessed in terms of the intended use of a method and, in the case of change or modification of a method, whether that change or modification may affect a previously validated performance characteristic. In general, method validation involves method scope, calibration-related parameters, method precision, and recovery. Any method change which may affect method scope or any performance parameters will require re-validation. Some typical situations involving change in methods are discussed and a decision process proposed for selection of appropriate validation measures. © 2012 John Wiley & Sons, Ltd.

  10. Content validity of methods to assess malnutrition in cancer patients: a systematic review

    NARCIS (Netherlands)

    Sealy, Martine; Nijholt, Willemke; Stuiver, M.M.; van der Berg, M.M.; Ottery, Faith D.; van der Schans, Cees; Roodenburg, Jan L N; Jager-Wittenaar, Harriët

    Content validity of methods to assess malnutrition in cancer patients: A systematic review Rationale: Inadequate operationalisation of the multidimensial concept of malnutrition may result in inadequate evaluation of nutritional status. In this review we aimed to assess content validity of methods

  11. Validation parameters of instrumental method for determination of total bacterial count in milk

    Directory of Open Access Journals (Sweden)

    Nataša Mikulec

    2004-10-01

    Full Text Available The method of flow citometry as rapid, instrumental and routine microbiological method is used for determination of total bacterial count in milk. The results of flow citometry are expressed as individual bacterial cells count. Problems regarding the interpretation of the results of total bacterial count can be avoided by transformation of the results of flow citometry method onto the scale of reference method (HRN ISO 6610:2001.. The method of flow citometry, like any analitycal method, according to the HRN EN ISO/IEC 17025:2000 standard, requires validation and verification. This paper describes parameters of validation: accuracy, precision, specificity, range, robustness and measuring uncertainty for the method of flow citometry.

  12. Pre-validation methods for developing a patient reported outcome instrument

    Directory of Open Access Journals (Sweden)

    Castillo Mayret M

    2011-08-01

    Full Text Available Abstract Background Measures that reflect patients' assessment of their health are of increasing importance as outcome measures in randomised controlled trials. The methodological approach used in the pre-validation development of new instruments (item generation, item reduction and question formatting should be robust and transparent. The totality of the content of existing PRO instruments for a specific condition provides a valuable resource (pool of items that can be utilised to develop new instruments. Such 'top down' approaches are common, but the explicit pre-validation methods are often poorly reported. This paper presents a systematic and generalisable 5-step pre-validation PRO instrument methodology. Methods The method is illustrated using the example of the Aberdeen Glaucoma Questionnaire (AGQ. The five steps are: 1 Generation of a pool of items; 2 Item de-duplication (three phases; 3 Item reduction (two phases; 4 Assessment of the remaining items' content coverage against a pre-existing theoretical framework appropriate to the objectives of the instrument and the target population (e.g. ICF; and 5 qualitative exploration of the target populations' views of the new instrument and the items it contains. Results The AGQ 'item pool' contained 725 items. Three de-duplication phases resulted in reduction of 91, 225 and 48 items respectively. The item reduction phases discarded 70 items and 208 items respectively. The draft AGQ contained 83 items with good content coverage. The qualitative exploration ('think aloud' study resulted in removal of a further 15 items and refinement to the wording of others. The resultant draft AGQ contained 68 items. Conclusions This study presents a novel methodology for developing a PRO instrument, based on three sources: literature reporting what is important to patient; theoretically coherent framework; and patients' experience of completing the instrument. By systematically accounting for all items dropped

  13. A validation of direct grey Dancoff factors results for cylindrical cells in cluster geometry by the Monte Carlo method

    International Nuclear Information System (INIS)

    Rodrigues, Leticia Jenisch; Bogado, Sergio; Vilhena, Marco T.

    2008-01-01

    The WIMS code is a well known and one of the most used codes to handle nuclear core physics calculations. Recently, the PIJM module of the WIMS code was modified in order to allow the calculation of Grey Dancoff factors, for partially absorbing materials, using the alternative definition in terms of escape and collision probabilities. Grey Dancoff factors for the Canadian CANDU-37 and CANFLEX assemblies were calculated with PIJM at five symmetrically distinct fuel pin positions. The results, obtained via Direct Method, i.e., by direct calculation of escape and collision probabilities, were satisfactory when compared with the ones of literature. On the other hand, the PIJMC module was developed to calculate escape and collision probabilities using Monte Carlo method. Modifications in this module were performed to determine Black Dancoff factors, considering perfectly absorbing fuel rods. In this work, we proceed further in the task of validating the Direct Method by the Monte Carlo approach. To this end, the PIJMC routine is modified to compute Grey Dancoff factors using the cited alternative definition. Results are reported for the mentioned CANDU-37 and CANFLEX assemblies obtained with PIJMC, at the same fuel pin positions as with PIJM. A good agreement is observed between the results from the Monte Carlo and Direct methods

  14. Laboratory diagnostic methods, system of quality and validation

    Directory of Open Access Journals (Sweden)

    Ašanin Ružica

    2005-01-01

    Full Text Available It is known that laboratory investigations secure safe and reliable results that provide a final confirmation of the quality of work. Ideas, planning, knowledge, skills, experience, and environment, along with good laboratory practice, quality control and reliability of quality, make the area of biological investigations very complex. In recent years, quality control, including the control of work in the laboratory, is based on international standards and is used at that level. The implementation of widely recognized international standards, such as the International Standard ISO/IEC 17025 (1 and the implementing of the quality system series ISO/IEC 9000 (2 have become the imperative on the grounds of which laboratories have a formal, visible and corresponding system of quality. The diagnostic methods that are used must constantly yield results which identify the animal as positive or negative, and the precise status of the animal is determined with a predefined degree of statistical significance. Methods applied on a selected population reduce the risk of obtaining falsely positive or falsely negative results. A condition for this are well conceived and documented methods, with the application of the corresponding reagents, and work with professional and skilled staff. This process requires also a consistent implementation of the most rigorous experimental plans, epidemiological and statistical data and estimations, with constant monitoring of the validity of the applied methods. Such an approach is necessary in order to cut down the number of misconceptions and accidental mistakes, for a referent population of animals on which the validity of a method is tested. Once a valid method is included in daily routine investigations, it is necessary to apply constant monitoring for the purpose of internal quality control, in order adequately to evaluate its reproducibility and reliability. Consequently, it is necessary at least twice yearly to conduct

  15. Increased efficacy for in-house validation of real-time PCR GMO detection methods.

    Science.gov (United States)

    Scholtens, I M J; Kok, E J; Hougs, L; Molenaar, B; Thissen, J T N M; van der Voet, H

    2010-03-01

    To improve the efficacy of the in-house validation of GMO detection methods (DNA isolation and real-time PCR, polymerase chain reaction), a study was performed to gain insight in the contribution of the different steps of the GMO detection method to the repeatability and in-house reproducibility. In the present study, 19 methods for (GM) soy, maize canola and potato were validated in-house of which 14 on the basis of an 8-day validation scheme using eight different samples and five on the basis of a more concise validation protocol. In this way, data was obtained with respect to the detection limit, accuracy and precision. Also, decision limits were calculated for declaring non-conformance (>0.9%) with 95% reliability. In order to estimate the contribution of the different steps in the GMO analysis to the total variation variance components were estimated using REML (residual maximum likelihood method). From these components, relative standard deviations for repeatability and reproducibility (RSD(r) and RSD(R)) were calculated. The results showed that not only the PCR reaction but also the factors 'DNA isolation' and 'PCR day' are important factors for the total variance and should therefore be included in the in-house validation. It is proposed to use a statistical model to estimate these factors from a large dataset of initial validations so that for similar GMO methods in the future, only the PCR step needs to be validated. The resulting data are discussed in the light of agreed European criteria for qualified GMO detection methods.

  16. Method development and validation of potent pyrimidine derivative by UV-VIS spectrophotometer.

    Science.gov (United States)

    Chaudhary, Anshu; Singh, Anoop; Verma, Prabhakar Kumar

    2014-12-01

    A rapid and sensitive ultraviolet-visible (UV-VIS) spectroscopic method was developed for the estimation of pyrimidine derivative 6-Bromo-3-(6-(2,6-dichlorophenyl)-2-(morpolinomethylamino) pyrimidine4-yl) -2H-chromen-2-one (BT10M) in bulk form. Pyrimidine derivative was monitored at 275 nm with UV detection, and there is no interference of diluents at 275 nm. The method was found to be linear in the range of 50 to 150 μg/ml. The accuracy and precision were determined and validated statistically. The method was validated as a guideline. The results showed that the proposed method is suitable for the accurate, precise, and rapid determination of pyrimidine derivative. Graphical Abstract Method development and validation of potent pyrimidine derivative by UV spectroscopy.

  17. Development and Validation of a Dissolution Test Method for ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a dissolution test method for dissolution release of artemether and lumefantrine from tablets. Methods: A single dissolution method for evaluating the in vitro release of artemether and lumefantrine from tablets was developed and validated. The method comprised of a dissolution medium of ...

  18. The Method of Manufactured Universes for validating uncertainty quantification methods

    KAUST Repository

    Stripling, H.F.; Adams, M.L.; McClarren, R.G.; Mallick, B.K.

    2011-01-01

    The Method of Manufactured Universes is presented as a validation framework for uncertainty quantification (UQ) methodologies and as a tool for exploring the effects of statistical and modeling assumptions embedded in these methods. The framework

  19. A chromatographic method validation to quantify tablets Mephenesine of national production

    International Nuclear Information System (INIS)

    Suarez Perez, Yania; Izquierdo Castro, Adalberto; Milian Sanchez, Jana Daria

    2009-01-01

    Authors made validation of an analytical method by high performance liquid chromatography (HPLC) for quantification of Mephenesine in recently reformulated 500 mg tablets. With regard to its application to quality control, validation included the following parameters: linearity, accuracy, precision, and selectivity. Results were satisfactory within 50-150 % rank. In the case of its use in subsequent studies of chemical stability, the selectivity for stability and sensitivity was assessed. Estimated detection and quantification limits were appropriate, and the method was selective versus the possible degradation products. (Author)

  20. Experimental validation for calcul methods of structures having shock non-linearity

    International Nuclear Information System (INIS)

    Brochard, D.; Buland, P.

    1987-01-01

    For the seismic analysis of non-linear structures, numerical methods have been developed which need to be validated on experimental results. The aim of this paper is to present the design method of a test program which results will be used for this purpose. Some applications to nuclear components will illustrate this presentation [fr

  1. Human Factors methods concerning integrated validation of nuclear power plant control rooms; Metodutveckling foer integrerad validering

    Energy Technology Data Exchange (ETDEWEB)

    Oskarsson, Per-Anders; Johansson, Bjoern J.E.; Gonzalez, Natalia (Swedish Defence Research Agency, Information Systems, Linkoeping (Sweden))

    2010-02-15

    The frame of reference for this work was existing recommendations and instructions from the NPP area, experiences from the review of the Turbic Validation and experiences from system validations performed at the Swedish Armed Forces, e.g. concerning military control rooms and fighter pilots. These enterprises are characterized by complex systems in extreme environments, often with high risks, where human error can lead to serious consequences. A focus group has been performed with representatives responsible for Human Factors issues from all Swedish NPP:s. The questions that were discussed were, among other things, for whom an integrated validation (IV) is performed and its purpose, what should be included in an IV, the comparison with baseline measures, the design process, the role of SSM, which methods of measurement should be used, and how the methods are affected of changes in the control room. The report brings different questions to discussion concerning the validation process. Supplementary methods of measurement for integrated validation are discussed, e.g. dynamic, psychophysiological, and qualitative methods for identification of problems. Supplementary methods for statistical analysis are presented. The study points out a number of deficiencies in the validation process, e.g. the need of common guidelines for validation and design, criteria for different types of measurements, clarification of the role of SSM, and recommendations for the responsibility of external participants in the validation process. The authors propose 12 measures for taking care of the identified problems

  2. Robustness study in SSNTD method validation: indoor radon quality

    Energy Technology Data Exchange (ETDEWEB)

    Dias, D.C.S.; Silva, N.C.; Bonifácio, R.L., E-mail: danilacdias@gmail.com [Comissao Nacional de Energia Nuclear (LAPOC/CNEN), Pocos de Caldas, MG (Brazil). Laboratorio de Pocos de Caldas

    2017-07-01

    Quality control practices are indispensable to organizations aiming to reach analytical excellence. Method validation is an essential component to quality systems in laboratories, serving as a powerful tool for standardization and reliability of outcomes. This paper presents a study of robustness conducted over a SSNTD technique validation process, with the goal of developing indoor radon measurements at the highest level of quality. This quality parameter indicates how well a technique is able to provide reliable results in face of unexpected variations along the measurement. In this robustness study, based on the Youden method, 7 analytical conditions pertaining to different phases of the SSNTD technique (with focus on detector etching) were selected. Based on the ideal values for each condition as reference, extreme levels regarded as high and low were prescribed to each condition. A partial factorial design of 8 unique etching procedures was defined, where each presented their own set of high and low condition values. The Youden test provided 8 indoor radon concentration results, which allowed percentage estimations that indicate the potential influence of each analytical condition on the SSNTD technique. As expected, detector etching factors such as etching solution concentration, temperature and immersion time were identified as the most critical parameters to the technique. Detector etching is a critical step in the SSNTD method – one that must be carefully designed during validation and meticulously controlled throughout the entire process. (author)

  3. Robustness study in SSNTD method validation: indoor radon quality

    International Nuclear Information System (INIS)

    Dias, D.C.S.; Silva, N.C.; Bonifácio, R.L.

    2017-01-01

    Quality control practices are indispensable to organizations aiming to reach analytical excellence. Method validation is an essential component to quality systems in laboratories, serving as a powerful tool for standardization and reliability of outcomes. This paper presents a study of robustness conducted over a SSNTD technique validation process, with the goal of developing indoor radon measurements at the highest level of quality. This quality parameter indicates how well a technique is able to provide reliable results in face of unexpected variations along the measurement. In this robustness study, based on the Youden method, 7 analytical conditions pertaining to different phases of the SSNTD technique (with focus on detector etching) were selected. Based on the ideal values for each condition as reference, extreme levels regarded as high and low were prescribed to each condition. A partial factorial design of 8 unique etching procedures was defined, where each presented their own set of high and low condition values. The Youden test provided 8 indoor radon concentration results, which allowed percentage estimations that indicate the potential influence of each analytical condition on the SSNTD technique. As expected, detector etching factors such as etching solution concentration, temperature and immersion time were identified as the most critical parameters to the technique. Detector etching is a critical step in the SSNTD method – one that must be carefully designed during validation and meticulously controlled throughout the entire process. (author)

  4. Content Validity of National Post Marriage Educational Program Using Mixed Methods

    Science.gov (United States)

    MOHAJER RAHBARI, Masoumeh; SHARIATI, Mohammad; KERAMAT, Afsaneh; YUNESIAN, Masoud; ESLAMI, Mohammad; MOUSAVI, Seyed Abbas; MONTAZERI, Ali

    2015-01-01

    Background: Although the validity of content of program is mostly conducted with qualitative methods, this study used both qualitative and quantitative methods for the validation of content of post marriage training program provided for newly married couples. Content validity is a preliminary step of obtaining authorization required to install the program in country's health care system. Methods: This mixed methodological content validation study carried out in four steps with forming three expert panels. Altogether 24 expert panelists were involved in 3 qualitative and quantitative panels; 6 in the first item development one; 12 in the reduction kind, 4 of them were common with the first panel, and 10 executive experts in the last one organized to evaluate psychometric properties of CVR and CVI and Face validity of 57 educational objectives. Results: The raw data of post marriage program had been written by professional experts of Ministry of Health, using qualitative expert panel, the content was more developed by generating 3 topics and refining one topic and its respective content. In the second panel, totally six other objectives were deleted, three for being out of agreement cut of point and three on experts' consensus. The validity of all items was above 0.8 and their content validity indices (0.8–1) were completely appropriate in quantitative assessment. Conclusion: This study provided a good evidence for validation and accreditation of national post marriage program planned for newly married couples in health centers of the country in the near future. PMID:26056672

  5. A validated RP-HPLC method for the determination of Irinotecan hydrochloride residues for cleaning validation in production area

    Directory of Open Access Journals (Sweden)

    Sunil Reddy

    2013-03-01

    Full Text Available Introduction: cleaning validation is an integral part of current good manufacturing practices in pharmaceutical industry. The main purpose of cleaning validation is to prove the effectiveness and consistency of cleaning in a given pharmaceutical production equipment to prevent cross contamination and adulteration of drug product with other active ingredient. Objective: a rapid, sensitive and specific reverse phase HPLC method was developed and validated for the quantitative determination of irinotecan hydrochloride in cleaning validation swab samples. Method: the method was validated using waters symmetry shield RP-18 (250mm x 4.6mm 5 µm column with isocratic mobile phase containing a mixture of 0.02 M potassium di-hydrogen ortho-phosphate, pH adjusted to 3.5 with ortho-phosphoric acid, methanol and acetonitrile (60:20:20 v/v/v. The flow rate of mobile phase was 1.0 mL/min with column temperature of 25°C and detection wavelength at 220nm. The sample injection volume was 100 µl. Results: the calibration curve was linear over a concentration range from 0.024 to 0.143 µg/mL with a correlation coefficient of 0.997. The intra-day and inter-day precision expressed as relative standard deviation were below 3.2%. The recoveries obtained from stainless steel, PCGI, epoxy, glass and decron cloth surfaces were more than 85% and there was no interference from the cotton swab. The detection limit (DL and quantitation limit (QL were 0.008 and 0.023 µg ml-1, respectively. Conclusion: the developed method was validated with respect to specificity, linearity, limit of detection and quantification, accuracy, precision and solution stability. The overall procedure can be used as part of a cleaning validation program in pharmaceutical manufacture of irinotecan hydrochloride.

  6. Microscale validation of 4-aminoantipyrine test method for quantifying phenolic compounds in microbial culture

    International Nuclear Information System (INIS)

    Justiz Mendoza, Ibrahin; Aguilera Rodriguez, Isabel; Perez Portuondo, Irasema

    2014-01-01

    Validation of test methods microscale is currently of great importance due to the economic and environmental advantages possessed, which constitutes a prerequisite for the performance of services and quality assurance of the results to provide customer. This paper addresses the microscale validation of 4-aminoantipyrine spectrophotometric method for the quantification of phenolic compounds in culture medium. Parameters linearity, precision, regression, accuracy, detection limits, quantification limits and robustness were evaluated, addition to the comparison test with no standardized method for determining polyphenols (Folin Ciocalteu). The results showed that both methods are feasible for determining phenols

  7. ASTM Validates Air Pollution Test Methods

    Science.gov (United States)

    Chemical and Engineering News, 1973

    1973-01-01

    The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)

  8. A Generalized Pivotal Quantity Approach to Analytical Method Validation Based on Total Error.

    Science.gov (United States)

    Yang, Harry; Zhang, Jianchun

    2015-01-01

    The primary purpose of method validation is to demonstrate that the method is fit for its intended use. Traditionally, an analytical method is deemed valid if its performance characteristics such as accuracy and precision are shown to meet prespecified acceptance criteria. However, these acceptance criteria are not directly related to the method's intended purpose, which is usually a gurantee that a high percentage of the test results of future samples will be close to their true values. Alternate "fit for purpose" acceptance criteria based on the concept of total error have been increasingly used. Such criteria allow for assessing method validity, taking into account the relationship between accuracy and precision. Although several statistical test methods have been proposed in literature to test the "fit for purpose" hypothesis, the majority of the methods are not designed to protect the risk of accepting unsuitable methods, thus having the potential to cause uncontrolled consumer's risk. In this paper, we propose a test method based on generalized pivotal quantity inference. Through simulation studies, the performance of the method is compared to five existing approaches. The results show that both the new method and the method based on β-content tolerance interval with a confidence level of 90%, hereafter referred to as the β-content (0.9) method, control Type I error and thus consumer's risk, while the other existing methods do not. It is further demonstrated that the generalized pivotal quantity method is less conservative than the β-content (0.9) method when the analytical methods are biased, whereas it is more conservative when the analytical methods are unbiased. Therefore, selection of either the generalized pivotal quantity or β-content (0.9) method for an analytical method validation depends on the accuracy of the analytical method. It is also shown that the generalized pivotal quantity method has better asymptotic properties than all of the current

  9. Do qualitative methods validate choice experiment-results? A case study on the economic valuation of peatland restoration in Central Kalimantan, Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Schaafsma, M.; Van Beukering, P.J.H.; Davies, O.; Oskolokaite, I.

    2009-05-15

    This study explores the benefits of combining independent results of qualitative focus group discussions (FGD) with a quantitative choice experiment (CE) in a developing country context. The assessment addresses the compensation needed by local communities in Central Kalimantan to cooperate in peatland restoration programs by using a CE combined with a series of FGD to validate and explain the CE-results. The main conclusion of this study is that a combination of qualitative and quantitative methods is necessary to assess the economic value of ecological services in monetary terms and to better understand the underlying attitudes and motives that drive these outcomes. The FGD not only cross-validate results of the CE, but also help to interpret the differences in preferences of respondents arising from environmental awareness and ecosystem characteristics. The FGD confirms that the CE results provide accurate information for ecosystem valuation. Additional to the advantages of FGD listed in the literature, this study finds that FGD provide the possibility to identify the specific terms and conditions on which respondents will accept land-use change scenarios. The results show that FGD may help to address problems regarding the effects of distribution of costs and benefits over time that neo-classical economic theory poses for the interpretation of economic valuation results in the demand it puts on the rationality of trade-offs and the required calculations.

  10. Toward a Unified Validation Framework in Mixed Methods Research

    Science.gov (United States)

    Dellinger, Amy B.; Leech, Nancy L.

    2007-01-01

    The primary purpose of this article is to further discussions of validity in mixed methods research by introducing a validation framework to guide thinking about validity in this area. To justify the use of this framework, the authors discuss traditional terminology and validity criteria for quantitative and qualitative research, as well as…

  11. Results of a survey on accident and safety analysis codes, benchmarks, verification and validation methods

    International Nuclear Information System (INIS)

    Lee, A.G.; Wilkin, G.B.

    1995-01-01

    This report is a compilation of the information submitted by AECL, CIAE, JAERI, ORNL and Siemens in response to a need identified at the 'Workshop on R and D Needs' at the IGORR-3 meeting. The survey compiled information on the national standards applied to the Safety Quality Assurance (SQA) programs undertaken by the participants. Information was assembled for the computer codes and nuclear data libraries used in accident and safety analyses for research reactors and the methods used to verify and validate the codes and libraries. Although the survey was not comprehensive, it provides a basis for exchanging information of common interest to the research reactor community

  12. Validation of single-sample doubly labeled water method

    International Nuclear Information System (INIS)

    Webster, M.D.; Weathers, W.W.

    1989-01-01

    We have experimentally validated a single-sample variant of the doubly labeled water method for measuring metabolic rate and water turnover in a very small passerine bird, the verdin (Auriparus flaviceps). We measured CO 2 production using the Haldane gravimetric technique and compared these values with estimates derived from isotopic data. Doubly labeled water results based on the one-sample calculations differed from Haldane values by less than 0.5% on average (range -8.3 to 11.2%, n = 9). Water flux computed by the single-sample method differed by -1.5% on average from results for the same birds based on the standard, two-sample technique (range -13.7 to 2.0%, n = 9)

  13. Methods for Geometric Data Validation of 3d City Models

    Science.gov (United States)

    Wagner, D.; Alam, N.; Wewetzer, M.; Pries, M.; Coors, V.

    2015-12-01

    Geometric quality of 3D city models is crucial for data analysis and simulation tasks, which are part of modern applications of the data (e.g. potential heating energy consumption of city quarters, solar potential, etc.). Geometric quality in these contexts is however a different concept as it is for 2D maps. In the latter case, aspects such as positional or temporal accuracy and correctness represent typical quality metrics of the data. They are defined in ISO 19157 and should be mentioned as part of the metadata. 3D data has a far wider range of aspects which influence their quality, plus the idea of quality itself is application dependent. Thus, concepts for definition of quality are needed, including methods to validate these definitions. Quality on this sense means internal validation and detection of inconsistent or wrong geometry according to a predefined set of rules. A useful starting point would be to have correct geometry in accordance with ISO 19107. A valid solid should consist of planar faces which touch their neighbours exclusively in defined corner points and edges. No gaps between them are allowed, and the whole feature must be 2-manifold. In this paper, we present methods to validate common geometric requirements for building geometry. Different checks based on several algorithms have been implemented to validate a set of rules derived from the solid definition mentioned above (e.g. water tightness of the solid or planarity of its polygons), as they were developed for the software tool CityDoctor. The method of each check is specified, with a special focus on the discussion of tolerance values where they are necessary. The checks include polygon level checks to validate the correctness of each polygon, i.e. closeness of the bounding linear ring and planarity. On the solid level, which is only validated if the polygons have passed validation, correct polygon orientation is checked, after self-intersections outside of defined corner points and edges

  14. When Educational Material Is Delivered: A Mixed Methods Content Validation Study of the Information Assessment Method.

    Science.gov (United States)

    Badran, Hani; Pluye, Pierre; Grad, Roland

    2017-03-14

    The Information Assessment Method (IAM) allows clinicians to report the cognitive impact, clinical relevance, intention to use, and expected patient health benefits associated with clinical information received by email. More than 15,000 Canadian physicians and pharmacists use the IAM in continuing education programs. In addition, information providers can use IAM ratings and feedback comments from clinicians to improve their products. Our general objective was to validate the IAM questionnaire for the delivery of educational material (ecological and logical content validity). Our specific objectives were to measure the relevance and evaluate the representativeness of IAM items for assessing information received by email. A 3-part mixed methods study was conducted (convergent design). In part 1 (quantitative longitudinal study), the relevance of IAM items was measured. Participants were 5596 physician members of the Canadian Medical Association who used the IAM. A total of 234,196 ratings were collected in 2012. The relevance of IAM items with respect to their main construct was calculated using descriptive statistics (relevance ratio R). In part 2 (qualitative descriptive study), the representativeness of IAM items was evaluated. A total of 15 family physicians completed semistructured face-to-face interviews. For each construct, we evaluated the representativeness of IAM items using a deductive-inductive thematic qualitative data analysis. In part 3 (mixing quantitative and qualitative parts), results from quantitative and qualitative analyses were reviewed, juxtaposed in a table, discussed with experts, and integrated. Thus, our final results are derived from the views of users (ecological content validation) and experts (logical content validation). Of the 23 IAM items, 21 were validated for content, while 2 were removed. In part 1 (quantitative results), 21 items were deemed relevant, while 2 items were deemed not relevant (R=4.86% [N=234,196] and R=3.04% [n

  15. Session-RPE Method for Training Load Monitoring: Validity, Ecological Usefulness, and Influencing Factors

    Directory of Open Access Journals (Sweden)

    Monoem Haddad

    2017-11-01

    Full Text Available Purpose: The aim of this review is to (1 retrieve all data validating the Session-rating of perceived exertion (RPE-method using various criteria, (2 highlight the rationale of this method and its ecological usefulness, and (3 describe factors that can alter RPE and users of this method should take into consideration.Method: Search engines such as SPORTDiscus, PubMed, and Google Scholar databases in the English language between 2001 and 2016 were consulted for the validity and usefulness of the session-RPE method. Studies were considered for further analysis when they used the session-RPE method proposed by Foster et al. in 2001. Participants were athletes of any gender, age, or level of competition. Studies using languages other than English were excluded in the analysis of the validity and reliability of the session-RPE method. Other studies were examined to explain the rationale of the session-RPE method and the origin of RPE.Results: A total of 950 studies cited the Foster et al. study that proposed the session RPE-method. 36 studies have examined the validity and reliability of this proposed method using the modified CR-10.Conclusion: These studies confirmed the validity and good reliability and internal consistency of session-RPE method in several sports and physical activities with men and women of different age categories (children, adolescents, and adults among various expertise levels. This method could be used as “standing alone” method for training load (TL monitoring purposes though some recommend to combine it with other physiological parameters as heart rate.

  16. Model-Based Method for Sensor Validation

    Science.gov (United States)

    Vatan, Farrokh

    2012-01-01

    Fault detection, diagnosis, and prognosis are essential tasks in the operation of autonomous spacecraft, instruments, and in situ platforms. One of NASA s key mission requirements is robust state estimation. Sensing, using a wide range of sensors and sensor fusion approaches, plays a central role in robust state estimation, and there is a need to diagnose sensor failure as well as component failure. Sensor validation can be considered to be part of the larger effort of improving reliability and safety. The standard methods for solving the sensor validation problem are based on probabilistic analysis of the system, from which the method based on Bayesian networks is most popular. Therefore, these methods can only predict the most probable faulty sensors, which are subject to the initial probabilities defined for the failures. The method developed in this work is based on a model-based approach and provides the faulty sensors (if any), which can be logically inferred from the model of the system and the sensor readings (observations). The method is also more suitable for the systems when it is hard, or even impossible, to find the probability functions of the system. The method starts by a new mathematical description of the problem and develops a very efficient and systematic algorithm for its solution. The method builds on the concepts of analytical redundant relations (ARRs).

  17. Validated modified Lycopodium spore method development for ...

    African Journals Online (AJOL)

    Validated modified lycopodium spore method has been developed for simple and rapid quantification of herbal powdered drugs. Lycopodium spore method was performed on ingredients of Shatavaryadi churna, an ayurvedic formulation used as immunomodulator, galactagogue, aphrodisiac and rejuvenator. Estimation of ...

  18. Validation method training: nurses' experiences and ratings of work climate.

    Science.gov (United States)

    Söderlund, Mona; Norberg, Astrid; Hansebo, Görel

    2014-03-01

    Training nursing staff in communication skills can impact on the quality of care for residents with dementia and contributes to nurses' job satisfaction. Changing attitudes and practices takes time and energy and can affect the entire nursing staff, not just the nurses directly involved in a training programme. Therefore, it seems important to study nurses' experiences of a training programme and any influence of the programme on work climate among the entire nursing staff. To explore nurses' experiences of a 1-year validation method training programme conducted in a nursing home for residents with dementia and to describe ratings of work climate before and after the programme. A mixed-methods approach. Twelve nurses participated in the training and were interviewed afterwards. These individual interviews were tape-recorded and transcribed, then analysed using qualitative content analysis. The Creative Climate Questionnaire was administered before (n = 53) and after (n = 56) the programme to the entire nursing staff in the participating nursing home wards and analysed with descriptive statistics. Analysis of the interviews resulted in four categories: being under extra strain, sharing experiences, improving confidence in care situations and feeling uncertain about continuing the validation method. The results of the questionnaire on work climate showed higher mean values in the assessment after the programme had ended. The training strengthened the participating nurses in caring for residents with dementia, but posed an extra strain on them. These nurses also described an extra strain on the entire nursing staff that was not reflected in the results from the questionnaire. The work climate at the nursing home wards might have made it easier to conduct this extensive training programme. Training in the validation method could develop nurses' communication skills and improve their handling of complex care situations. © 2013 Blackwell Publishing Ltd.

  19. Method validation for strobilurin fungicides in cereals and fruit

    DEFF Research Database (Denmark)

    Christensen, Hanne Bjerre; Granby, Kit

    2001-01-01

    Strobilurins are a new class of fungicides that are active against a broad spectrum of fungi. In the present work a GC method for analysis of strobilurin fungicides was validated. The method was based on extraction with ethyl acetate/cyclohexane, clean-up by gel permeation chromatography (GPC......) and determination of the content by gas chromatography (GC) with electron capture (EC-), nitrogen/phosphorous (NP-), and mass spectrometric (MS-) detection. Three strobilurins, azoxystrobin, kresoxim-methyl and trifloxystrobin were validated on three matrices, wheat, apple and grapes. The validation was based...

  20. 76 FR 28664 - Method 301-Field Validation of Pollutant Measurement Methods From Various Waste Media

    Science.gov (United States)

    2011-05-18

    ... . d m = The mean of the paired sample differences. n = Total number of paired samples. 7.4.2 t Test... being compared to a validated test method as part of the Method 301 validation and an audit sample for... tighten the acceptance criteria for the precision of candidate alternative test methods. One commenter...

  1. The Value of Qualitative Methods in Social Validity Research

    Science.gov (United States)

    Leko, Melinda M.

    2014-01-01

    One quality indicator of intervention research is the extent to which the intervention has a high degree of social validity, or practicality. In this study, I drew on Wolf's framework for social validity and used qualitative methods to ascertain five middle schoolteachers' perceptions of the social validity of System 44®--a phonics-based reading…

  2. Reliability and validity of non-radiographic methods of thoracic kyphosis measurement: a systematic review.

    Science.gov (United States)

    Barrett, Eva; McCreesh, Karen; Lewis, Jeremy

    2014-02-01

    A wide array of instruments are available for non-invasive thoracic kyphosis measurement. Guidelines for selecting outcome measures for use in clinical and research practice recommend that properties such as validity and reliability are considered. This systematic review reports on the reliability and validity of non-invasive methods for measuring thoracic kyphosis. A systematic search of 11 electronic databases located studies assessing reliability and/or validity of non-invasive thoracic kyphosis measurement techniques. Two independent reviewers used a critical appraisal tool to assess the quality of retrieved studies. Data was extracted by the primary reviewer. The results were synthesized qualitatively using a level of evidence approach. 27 studies satisfied the eligibility criteria and were included in the review. The reliability, validity and both reliability and validity were investigated by sixteen, two and nine studies respectively. 17/27 studies were deemed to be of high quality. In total, 15 methods of thoracic kyphosis were evaluated in retrieved studies. All investigated methods showed high (ICC ≥ .7) to very high (ICC ≥ .9) levels of reliability. The validity of the methods ranged from low to very high. The strongest levels of evidence for reliability exists in support of the Debrunner kyphometer, Spinal Mouse and Flexicurve index, and for validity supports the arcometer and Flexicurve index. Further reliability and validity studies are required to strengthen the level of evidence for the remaining methods of measurement. This should be addressed by future research. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Impurities in biogas - validation of analytical methods for siloxanes; Foeroreningar i biogas - validering av analysmetodik foer siloxaner

    Energy Technology Data Exchange (ETDEWEB)

    Arrhenius, Karine; Magnusson, Bertil; Sahlin, Eskil [SP Technical Research Institute of Sweden, Boraas (Sweden)

    2011-11-15

    Biogas produced from digester or landfill contains impurities which can be harmful for component that will be in contact with the biogas during its utilization. Among these, the siloxanes are often mentioned. During combustion, siloxanes are converted to silicon dioxide which accumulates on the heated surfaces in combustion equipment. Silicon dioxide is a solid compound and will remain in the engine and cause damages. Consequently, it is necessary to develop methods for the accurate determination of these compounds in biogases. In the first part of this report, a method for analysis of siloxanes in biogases was validated. The sampling was performed directly at the plant by drawing a small volume of biogas onto an adsorbent tube under a short period of time. These tubes were subsequently sent to the laboratory for analysis. The purpose of method validation is to demonstrate that the established method is fit for the purpose. This means that the method, as used by the laboratory generating the data, will provide data that meets a set of criteria concerning precision and accuracy. At the end, the uncertainty of the method was calculated. In the second part of this report, the validated method was applied to real samples collected in waste water treatment plants, co-digestion plants and plants digesting other wastes (agriculture waste). Results are presented at the end of this report. As expected, the biogases from waste water treatment plants contained largely higher concentrations of siloxanes than biogases from co-digestion plants and plants digesting agriculture wastes. The concentration of siloxanes in upgraded biogas regardless of which feedstock was digested and which upgrading technique was used was low.

  4. Validation of a same-day real-time PCR method for screening of meat and carcass swabs for Salmonella

    DEFF Research Database (Denmark)

    Löfström, Charlotta; Krause, Michael; Josefsen, Mathilde Hartmann

    2009-01-01

    of the published PCR methods for Salmonella have been validated in collaborative studies. This study describes a validation including comparative and collaborative trials, based on the recommendations from the Nordic organization for validation of alternative microbiological methods (NordVal) of a same-day, non....... Partly based on results obtained in this study, the method has obtained NordVal approval for analysis of Salmonella in meat and carcass swabs. The PCR method was transferred to a production laboratory and the performance was compared with the BAX Salmonella test on 39 pork samples artificially...... contaminated with Salmonella. There was no significant difference in the results obtained by the two methods. Conclusion: The real-time PCR method for detection of Salmonella in meat and carcass swabs was validated in comparative and collaborative trials according to NordVal recommendations. The PCR method...

  5. Space Suit Joint Torque Measurement Method Validation

    Science.gov (United States)

    Valish, Dana; Eversley, Karina

    2012-01-01

    In 2009 and early 2010, a test method was developed and performed to quantify the torque required to manipulate joints in several existing operational and prototype space suits. This was done in an effort to develop joint torque requirements appropriate for a new Constellation Program space suit system. The same test method was levied on the Constellation space suit contractors to verify that their suit design met the requirements. However, because the original test was set up and conducted by a single test operator there was some question as to whether this method was repeatable enough to be considered a standard verification method for Constellation or other future development programs. In order to validate the method itself, a representative subset of the previous test was repeated, using the same information that would be available to space suit contractors, but set up and conducted by someone not familiar with the previous test. The resultant data was compared using graphical and statistical analysis; the results indicated a significant variance in values reported for a subset of the re-tested joints. Potential variables that could have affected the data were identified and a third round of testing was conducted in an attempt to eliminate and/or quantify the effects of these variables. The results of the third test effort will be used to determine whether or not the proposed joint torque methodology can be applied to future space suit development contracts.

  6. A New Statistical Method to Determine the Degree of Validity of Health Economic Model Outcomes against Empirical Data.

    Science.gov (United States)

    Corro Ramos, Isaac; van Voorn, George A K; Vemer, Pepijn; Feenstra, Talitha L; Al, Maiwenn J

    2017-09-01

    The validation of health economic (HE) model outcomes against empirical data is of key importance. Although statistical testing seems applicable, guidelines for the validation of HE models lack guidance on statistical validation, and actual validation efforts often present subjective judgment of graphs and point estimates. To discuss the applicability of existing validation techniques and to present a new method for quantifying the degrees of validity statistically, which is useful for decision makers. A new Bayesian method is proposed to determine how well HE model outcomes compare with empirical data. Validity is based on a pre-established accuracy interval in which the model outcomes should fall. The method uses the outcomes of a probabilistic sensitivity analysis and results in a posterior distribution around the probability that HE model outcomes can be regarded as valid. We use a published diabetes model (Modelling Integrated Care for Diabetes based on Observational data) to validate the outcome "number of patients who are on dialysis or with end-stage renal disease." Results indicate that a high probability of a valid outcome is associated with relatively wide accuracy intervals. In particular, 25% deviation from the observed outcome implied approximately 60% expected validity. Current practice in HE model validation can be improved by using an alternative method based on assessing whether the model outcomes fit to empirical data at a predefined level of accuracy. This method has the advantage of assessing both model bias and parameter uncertainty and resulting in a quantitative measure of the degree of validity that penalizes models predicting the mean of an outcome correctly but with overly wide credible intervals. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  7. Roll-up of validation results to a target application.

    Energy Technology Data Exchange (ETDEWEB)

    Hills, Richard Guy

    2013-09-01

    Suites of experiments are preformed over a validation hierarchy to test computational simulation models for complex applications. Experiments within the hierarchy can be performed at different conditions and configurations than those for an intended application, with each experiment testing only part of the physics relevant for the application. The purpose of the present work is to develop methodology to roll-up validation results to an application, and to assess the impact the validation hierarchy design has on the roll-up results. The roll-up is accomplished through the development of a meta-model that relates validation measurements throughout a hierarchy to the desired response quantities for the target application. The meta-model is developed using the computation simulation models for the experiments and the application. The meta-model approach is applied to a series of example transport problems that represent complete and incomplete coverage of the physics of the target application by the validation experiments.

  8. VALUE - Validating and Integrating Downscaling Methods for Climate Change Research

    Science.gov (United States)

    Maraun, Douglas; Widmann, Martin; Benestad, Rasmus; Kotlarski, Sven; Huth, Radan; Hertig, Elke; Wibig, Joanna; Gutierrez, Jose

    2013-04-01

    Our understanding of global climate change is mainly based on General Circulation Models (GCMs) with a relatively coarse resolution. Since climate change impacts are mainly experienced on regional scales, high-resolution climate change scenarios need to be derived from GCM simulations by downscaling. Several projects have been carried out over the last years to validate the performance of statistical and dynamical downscaling, yet several aspects have not been systematically addressed: variability on sub-daily, decadal and longer time-scales, extreme events, spatial variability and inter-variable relationships. Different downscaling approaches such as dynamical downscaling, statistical downscaling and bias correction approaches have not been systematically compared. Furthermore, collaboration between different communities, in particular regional climate modellers, statistical downscalers and statisticians has been limited. To address these gaps, the EU Cooperation in Science and Technology (COST) action VALUE (www.value-cost.eu) has been brought into life. VALUE is a research network with participants from currently 23 European countries running from 2012 to 2015. Its main aim is to systematically validate and develop downscaling methods for climate change research in order to improve regional climate change scenarios for use in climate impact studies. Inspired by the co-design idea of the international research initiative "future earth", stakeholders of climate change information have been involved in the definition of research questions to be addressed and are actively participating in the network. The key idea of VALUE is to identify the relevant weather and climate characteristics required as input for a wide range of impact models and to define an open framework to systematically validate these characteristics. Based on a range of benchmark data sets, in principle every downscaling method can be validated and compared with competing methods. The results of

  9. ExEP yield modeling tool and validation test results

    Science.gov (United States)

    Morgan, Rhonda; Turmon, Michael; Delacroix, Christian; Savransky, Dmitry; Garrett, Daniel; Lowrance, Patrick; Liu, Xiang Cate; Nunez, Paul

    2017-09-01

    EXOSIMS is an open-source simulation tool for parametric modeling of the detection yield and characterization of exoplanets. EXOSIMS has been adopted by the Exoplanet Exploration Programs Standards Definition and Evaluation Team (ExSDET) as a common mechanism for comparison of exoplanet mission concept studies. To ensure trustworthiness of the tool, we developed a validation test plan that leverages the Python-language unit-test framework, utilizes integration tests for selected module interactions, and performs end-to-end crossvalidation with other yield tools. This paper presents the test methods and results, with the physics-based tests such as photometry and integration time calculation treated in detail and the functional tests treated summarily. The test case utilized a 4m unobscured telescope with an idealized coronagraph and an exoplanet population from the IPAC radial velocity (RV) exoplanet catalog. The known RV planets were set at quadrature to allow deterministic validation of the calculation of physical parameters, such as working angle, photon counts and integration time. The observing keepout region was tested by generating plots and movies of the targets and the keepout zone over a year. Although the keepout integration test required the interpretation of a user, the test revealed problems in the L2 halo orbit and the parameterization of keepout applied to some solar system bodies, which the development team was able to address. The validation testing of EXOSIMS was performed iteratively with the developers of EXOSIMS and resulted in a more robust, stable, and trustworthy tool that the exoplanet community can use to simulate exoplanet direct-detection missions from probe class, to WFIRST, up to large mission concepts such as HabEx and LUVOIR.

  10. Validation of methods for the detection and quantification of engineered nanoparticles in food

    DEFF Research Database (Denmark)

    Linsinger, T.P.J.; Chaudhry, Q.; Dehalu, V.

    2013-01-01

    the methods apply equally well to particles of different suppliers. In trueness testing, information whether the particle size distribution has changed during analysis is required. Results are largely expected to follow normal distributions due to the expected high number of particles. An approach...... approach for the validation of methods for detection and quantification of nanoparticles in food samples. It proposes validation of identity, selectivity, precision, working range, limit of detection and robustness, bearing in mind that each “result” must include information about the chemical identity...

  11. 42 CFR 476.84 - Changes as a result of DRG validation.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Changes as a result of DRG validation. 476.84... § 476.84 Changes as a result of DRG validation. A provider or practitioner may obtain a review by a QIO... in DRG assignment as a result of QIO validation activities. ...

  12. A Comparison of Three Methods for the Analysis of Skin Flap Viability: Reliability and Validity.

    Science.gov (United States)

    Tim, Carla Roberta; Martignago, Cintia Cristina Santi; da Silva, Viviane Ribeiro; Dos Santos, Estefany Camila Bonfim; Vieira, Fabiana Nascimento; Parizotto, Nivaldo Antonio; Liebano, Richard Eloin

    2018-05-01

    Objective: Technological advances have provided new alternatives to the analysis of skin flap viability in animal models; however, the interrater validity and reliability of these techniques have yet to be analyzed. The present study aimed to evaluate the interrater validity and reliability of three different methods: weight of paper template (WPT), paper template area (PTA), and photographic analysis. Approach: Sixteen male Wistar rats had their cranially based dorsal skin flap elevated. On the seventh postoperative day, the viable tissue area and the necrotic area of the skin flap were recorded using the paper template method and photo image. The evaluation of the percentage of viable tissue was performed using three methods, simultaneously and independently by two raters. The analysis of interrater reliability and viability was performed using the intraclass correlation coefficient and Bland Altman Plot Analysis was used to visualize the presence or absence of systematic bias in the evaluations of data validity. Results: The results showed that interrater reliability for WPT, measurement of PTA, and photographic analysis were 0.995, 0.990, and 0.982, respectively. For data validity, a correlation >0.90 was observed for all comparisons made between the three methods. In addition, Bland Altman Plot Analysis showed agreement between the comparisons of the methods and the presence of systematic bias was not observed. Innovation: Digital methods are an excellent choice for assessing skin flap viability; moreover, they make data use and storage easier. Conclusion: Independently from the method used, the interrater reliability and validity proved to be excellent for the analysis of skin flaps' viability.

  13. Validation of commercially available automated canine-specific immunoturbidimetric method for measuring canine C-reactive protein

    DEFF Research Database (Denmark)

    Hillström, Anna; Hagman, Ragnvi; Tvedten, Harold

    2014-01-01

    BACKGROUND: Measurement of C-reactive protein (CRP) is used for diagnosing and monitoring systemic inflammatory disease in canine patients. An automated human immunoturbidimetric assay has been validated for measuring canine CRP, but cross-reactivity with canine CRP is unpredictable. OBJECTIVE......: The purpose of the study was to validate a new automated canine-specific immunoturbidimetric CRP method (Gentian cCRP). METHODS: Studies of imprecision, accuracy, prozone effect, interference, limit of quantification, and stability under different storage conditions were performed. The new method was compared...... with a human CRP assay previously validated for canine CRP determination. Samples from 40 healthy dogs were analyzed to establish a reference interval. RESULTS: Total imprecision was

  14. Validation of Experimental whole-body SAR Assessment Method in a Complex Indoor Environment

    DEFF Research Database (Denmark)

    Bamba, Aliou; Joseph, Wout; Vermeeren, Gunter

    2012-01-01

    Assessing experimentally the whole-body specific absorption rate (SARwb) in a complex indoor environment is very challenging. An experimental method based on room electromagnetics theory (accounting only the Line-Of-Sight as specular path) to assess the whole-body SAR is validated by numerical...... of the proposed method is that it allows discarding the computation burden because it does not use any discretizations. Results show good agreement between measurement and computation at 2.8 GHz, as long as the plane wave assumption is valid, i.e., for high distances from the transmitter. Relative deviations 0...

  15. Improvement of Simulation Method in Validation of Software of the Coordinate Measuring Systems

    Science.gov (United States)

    Nieciąg, Halina

    2015-10-01

    Software is used in order to accomplish various tasks at each stage of the functioning of modern measuring systems. Before metrological confirmation of measuring equipment, the system has to be validated. This paper discusses the method for conducting validation studies of a fragment of software to calculate the values of measurands. Due to the number and nature of the variables affecting the coordinate measurement results and the complex character and multi-dimensionality of measurands, the study used the Monte Carlo method of numerical simulation. The article presents an attempt of possible improvement of results obtained by classic Monte Carlo tools. The algorithm LHS (Latin Hypercube Sampling) was implemented as alternative to the simple sampling schema of classic algorithm.

  16. International Harmonization and Cooperation in the Validation of Alternative Methods.

    Science.gov (United States)

    Barroso, João; Ahn, Il Young; Caldeira, Cristiane; Carmichael, Paul L; Casey, Warren; Coecke, Sandra; Curren, Rodger; Desprez, Bertrand; Eskes, Chantra; Griesinger, Claudius; Guo, Jiabin; Hill, Erin; Roi, Annett Janusch; Kojima, Hajime; Li, Jin; Lim, Chae Hyung; Moura, Wlamir; Nishikawa, Akiyoshi; Park, HyeKyung; Peng, Shuangqing; Presgrave, Octavio; Singer, Tim; Sohn, Soo Jung; Westmoreland, Carl; Whelan, Maurice; Yang, Xingfen; Yang, Ying; Zuang, Valérie

    The development and validation of scientific alternatives to animal testing is important not only from an ethical perspective (implementation of 3Rs), but also to improve safety assessment decision making with the use of mechanistic information of higher relevance to humans. To be effective in these efforts, it is however imperative that validation centres, industry, regulatory bodies, academia and other interested parties ensure a strong international cooperation, cross-sector collaboration and intense communication in the design, execution, and peer review of validation studies. Such an approach is critical to achieve harmonized and more transparent approaches to method validation, peer-review and recommendation, which will ultimately expedite the international acceptance of valid alternative methods or strategies by regulatory authorities and their implementation and use by stakeholders. It also allows achieving greater efficiency and effectiveness by avoiding duplication of effort and leveraging limited resources. In view of achieving these goals, the International Cooperation on Alternative Test Methods (ICATM) was established in 2009 by validation centres from Europe, USA, Canada and Japan. ICATM was later joined by Korea in 2011 and currently also counts with Brazil and China as observers. This chapter describes the existing differences across world regions and major efforts carried out for achieving consistent international cooperation and harmonization in the validation and adoption of alternative approaches to animal testing.

  17. Life cycle analysis of electricity systems: Methods and results

    International Nuclear Information System (INIS)

    Friedrich, R.; Marheineke, T.

    1996-01-01

    The two methods for full energy chain analysis, process analysis and input/output analysis, are discussed. A combination of these two methods provides the most accurate results. Such a hybrid analysis of the full energy chains of six different power plants is presented and discussed. The results of such analyses depend on time, site and technique of each process step and, therefore have no general validity. For renewable energy systems the emissions form the generation of a back-up system should be added. (author). 7 figs, 1 fig

  18. Validity of the CT to attenuation coefficient map conversion methods

    International Nuclear Information System (INIS)

    Faghihi, R.; Ahangari Shahdehi, R.; Fazilat Moadeli, M.

    2004-01-01

    The most important commercialized methods of attenuation correction in SPECT are based on attenuation coefficient map from a transmission imaging method. The transmission imaging system can be the linear source of radioelement or a X-ray CT system. The image of transmission imaging system is not useful unless to replacement of the attenuation coefficient or CT number with the attenuation coefficient in SPECT energy. In this paper we essay to evaluate the validity and estimate the error of the most used method of this transformation. The final result shows that the methods which use a linear or multi-linear curve accept a error in their estimation. The value of mA is not important but the patient thickness is very important and it can introduce a error more than 10 percent in the final result

  19. Comprehensive validation scheme for in situ fiber optics dissolution method for pharmaceutical drug product testing.

    Science.gov (United States)

    Mirza, Tahseen; Liu, Qian Julie; Vivilecchia, Richard; Joshi, Yatindra

    2009-03-01

    There has been a growing interest during the past decade in the use of fiber optics dissolution testing. Use of this novel technology is mainly confined to research and development laboratories. It has not yet emerged as a tool for end product release testing despite its ability to generate in situ results and efficiency improvement. One potential reason may be the lack of clear validation guidelines that can be applied for the assessment of suitability of fiber optics. This article describes a comprehensive validation scheme and development of a reliable, robust, reproducible and cost-effective dissolution test using fiber optics technology. The test was successfully applied for characterizing the dissolution behavior of a 40-mg immediate-release tablet dosage form that is under development at Novartis Pharmaceuticals, East Hanover, New Jersey. The method was validated for the following parameters: linearity, precision, accuracy, specificity, and robustness. In particular, robustness was evaluated in terms of probe sampling depth and probe orientation. The in situ fiber optic method was found to be comparable to the existing manual sampling dissolution method. Finally, the fiber optic dissolution test was successfully performed by different operators on different days, to further enhance the validity of the method. The results demonstrate that the fiber optics technology can be successfully validated for end product dissolution/release testing. (c) 2008 Wiley-Liss, Inc. and the American Pharmacists Association

  20. Development and Validation of Analytical Method for Losartan ...

    African Journals Online (AJOL)

    Development and Validation of Analytical Method for Losartan-Copper Complex Using UV-Vis Spectrophotometry. ... Tropical Journal of Pharmaceutical Research ... Purpose: To develop a new spectrophotometric method for the analysis of losartan potassium in pharmaceutical formulations by making its complex with ...

  1. Development and Validation of Improved Method for Fingerprint ...

    African Journals Online (AJOL)

    Purpose: To develop and validate an improved method by capillary zone electrophoresis with photodiode array detection for the fingerprint analysis of Ligusticum chuanxiong Hort. (Rhizoma Chuanxiong). Methods: The optimum high performance capillary electrophoresis (HPCE) conditions were 30 mM borax containing 5 ...

  2. Dependability validation by means of fault injection: method, implementation, application

    International Nuclear Information System (INIS)

    Arlat, Jean

    1990-01-01

    This dissertation presents theoretical and practical results concerning the use of fault injection as a means for testing fault tolerance in the framework of the experimental dependability validation of computer systems. The dissertation first presents the state-of-the-art of published work on fault injection, encompassing both hardware (fault simulation, physical fault Injection) and software (mutation testing) issues. Next, the major attributes of fault injection (faults and their activation, experimental readouts and measures, are characterized taking into account: i) the abstraction levels used to represent the system during the various phases of its development (analytical, empirical and physical models), and Il) the validation objectives (verification and evaluation). An evaluation method is subsequently proposed that combines the analytical modeling approaches (Monte Carlo Simulations, closed-form expressions. Markov chains) used for the representation of the fault occurrence process and the experimental fault Injection approaches (fault Simulation and physical injection); characterizing the error processing and fault treatment provided by the fault tolerance mechanisms. An experimental tool - MESSALINE - is then defined and presented. This tool enables physical faults to be Injected In an hardware and software prototype of the system to be validated. Finally, the application of MESSALINE for testing two fault-tolerant systems possessing very dissimilar features and the utilization of the experimental results obtained - both as design feedbacks and for dependability measures evaluation - are used to illustrate the relevance of the method. (author) [fr

  3. Validation of DRAGON side-step method for Bruce-A restart Phase-B physics tests

    International Nuclear Information System (INIS)

    Shen, W.; Ngo-Trong, C.; Davis, R.S.

    2004-01-01

    The DRAGON side-step method, developed at AECL, has a number of advantages over the all-DRAGON method that was used before. It is now the qualified method for reactivity-device calculations. Although the side-step-method-generated incremental cross sections have been validated against those previously calculated with the all-DRAGON method, it is highly desirable to validate the side-step method against device-worth measurements in power reactors directly. In this paper, the DRAGON side-step method was validated by comparison with the device-calibration measurements made in Bruce-A NGS Unit 4 restart Phase-B commissioning in 2003. The validation exercise showed excellent results, with the DRAGON code overestimating the measured ZCR worth by ∼5%. A sensitivity study was also performed in this paper to assess the effect of various DRAGON modelling techniques on the incremental cross sections. The assessment shows that the refinement of meshes in 3-D and the use of the side-step method are two major reasons contributing to the improved agreement between the calculated ZCR worths and the measurements. Use of different DRAGON versions, DRAGON libraries, local-parameter core conditions, and weighting techniques for the homogenization of tube clusters inside the ZCR have a very small effect on the ZCR incremental thermal absorption cross section and ZCR reactivity worth. (author)

  4. Validation of innovative technologies and strategies for regulatory safety assessment methods: challenges and opportunities.

    Science.gov (United States)

    Stokes, William S; Wind, Marilyn

    2010-01-01

    Advances in science and innovative technologies are providing new opportunities to develop test methods and strategies that may improve safety assessments and reduce animal use for safety testing. These include high throughput screening and other approaches that can rapidly measure or predict various molecular, genetic, and cellular perturbations caused by test substances. Integrated testing and decision strategies that consider multiple types of information and data are also being developed. Prior to their use for regulatory decision-making, new methods and strategies must undergo appropriate validation studies to determine the extent that their use can provide equivalent or improved protection compared to existing methods and to determine the extent that reproducible results can be obtained in different laboratories. Comprehensive and optimal validation study designs are expected to expedite the validation and regulatory acceptance of new test methods and strategies that will support improved safety assessments and reduced animal use for regulatory testing.

  5. USFDA-GUIDELINE BASED VALIDATION OF TESTING METHOD FOR RIFAMPICIN IN INDONESIAN SERUM SPECIMEN

    Directory of Open Access Journals (Sweden)

    Tri Joko Raharjo

    2010-06-01

    Full Text Available Regarding a new regulation from Indonesia FDA (Badan POM-RI, all new non patent drugs should show bioequivalence with the originator drug prior to registration. Bioequivalence testing (BE-testing has to be performed to the people that represented of population to which the drug to be administrated. BE testing need a valid bio-analytical method for certain drug target and group of population. This research report specific validation of bio-analysis of Rifampicin in Indonesian serum specimen in order to be used for BE testing. The extraction was performed using acetonitrile while the chromatographic separation was accomplished on a RP 18 column (250 × 4.6 mm i.d., 5 µm, with a mobile phase composed of KH2PO4 10 mM-Acetonitrile (40:60, v/v and UV detection was set at 333 nm. The method shown specificity compared to blank serum specimen with retention time of rifampicin at 2.1 min. Lower limit of quantification (LLOQ was 0.06 µg/mL with dynamic range up to 20 µg/mL (R>0.990. Precision of the method was very good with coefficient of variance (CV 0.58; 7.40 and 5.56% for concentration at 0.06, 5, 15 µg/mL, respectively. Accuracies of the method were 3.22; 1.94; 1.90% for concentration 0.06, 5 and 15 µg/mL respectively. The average recoveries were 97.82, 95.50 and 97.31% for concentration of rifampicin 1, 5 and 5 µg/mL, respectively. The method was also shown reliable result on stability test on freezing-thawing, short-term and long-term stability as well as post preparation stability. Validation result shown that the method was ready to be used for Rifampicin BE testing with Indonesian subject.   Keywords: Rifampicin, Validation, USFDA-Guideline

  6. Potential of accuracy profile for method validation in inductively coupled plasma spectrochemistry

    International Nuclear Information System (INIS)

    Mermet, J.M.; Granier, G.

    2012-01-01

    Method validation is usually performed over a range of concentrations for which analytical criteria must be verified. One important criterion in quantitative analysis is accuracy, i.e. the contribution of both trueness and precision. The study of accuracy over this range is called an accuracy profile and provides experimental tolerance intervals. Comparison with acceptability limits fixed by the end user defines a validity domain. This work describes the computation involved in the building of the tolerance intervals, particularly for the intermediate precision with within-laboratory experiments and for the reproducibility with interlaboratory studies. Computation is based on ISO 5725‐4 and on previously published work. Moreover, the bias uncertainty is also computed to verify the bias contribution to accuracy. The various types of accuracy profile behavior are exemplified with results obtained by using ICP-MS and ICP-AES. This procedure allows the analyst to define unambiguously a validity domain for a given accuracy. However, because the experiments are time-consuming, the accuracy profile method is mainly dedicated to method validation. - Highlights: ► An analytical method is defined by its accuracy, i.e. both trueness and precision. ► The accuracy as a function of an analyte concentration is an accuracy profile. ► Profile basic concepts are explained for trueness and intermediate precision. ► Profile-based tolerance intervals have to be compared with acceptability limits. ► Typical accuracy profiles are given for both ICP-AES and ICP-MS techniques.

  7. Development and validation of a spectroscopic method for the ...

    African Journals Online (AJOL)

    Development and validation of a spectroscopic method for the simultaneous analysis of ... advanced analytical methods such as high pressure liquid ..... equipment. DECLARATIONS ... high-performance liquid chromatography. J Chromatogr.

  8. Improvement of Simulation Method in Validation of Software of the Coordinate Measuring Systems

    Directory of Open Access Journals (Sweden)

    Nieciąg Halina

    2015-10-01

    Full Text Available Software is used in order to accomplish various tasks at each stage of the functioning of modern measuring systems. Before metrological confirmation of measuring equipment, the system has to be validated. This paper discusses the method for conducting validation studies of a fragment of software to calculate the values of measurands. Due to the number and nature of the variables affecting the coordinate measurement results and the complex character and multi-dimensionality of measurands, the study used the Monte Carlo method of numerical simulation. The article presents an attempt of possible improvement of results obtained by classic Monte Carlo tools. The algorithm LHS (Latin Hypercube Sampling was implemented as alternative to the simple sampling schema of classic algorithm.

  9. Development and validation of an alternative titration method for the determination of sulfate ion in indinavir sulfate

    Directory of Open Access Journals (Sweden)

    Breno de Carvalho e Silva

    2005-02-01

    Full Text Available A simple and rapid precipitation titration method was developed and validated to determine sulfate ion content in indinavir sulfate raw material. 0.1 mol L-1 lead nitrate volumetric solution was used as titrant employing potentiometric endpoint determination using a lead-specific electrode. The United States Pharmacopoeia Forum indicates a potentiometric method for sulfate ion quantitation using 0.1 mol L-1 lead perchlorate as titrant. Both methods were validated concerning linearity, precision and accuracy, yielding good results. The sulfate ion content found by the two validated methods was compared by the statistical t-student test, indicating that there was no statistically significant difference between the methods.

  10. Bayesian risk-based decision method for model validation under uncertainty

    International Nuclear Information System (INIS)

    Jiang Xiaomo; Mahadevan, Sankaran

    2007-01-01

    This paper develops a decision-making methodology for computational model validation, considering the risk of using the current model, data support for the current model, and cost of acquiring new information to improve the model. A Bayesian decision theory-based method is developed for this purpose, using a likelihood ratio as the validation metric for model assessment. An expected risk or cost function is defined as a function of the decision costs, and the likelihood and prior of each hypothesis. The risk is minimized through correctly assigning experimental data to two decision regions based on the comparison of the likelihood ratio with a decision threshold. A Bayesian validation metric is derived based on the risk minimization criterion. Two types of validation tests are considered: pass/fail tests and system response value measurement tests. The methodology is illustrated for the validation of reliability prediction models in a tension bar and an engine blade subjected to high cycle fatigue. The proposed method can effectively integrate optimal experimental design into model validation to simultaneously reduce the cost and improve the accuracy of reliability model assessment

  11. Likelihood ratio data to report the validation of a forensic fingerprint evaluation method

    Directory of Open Access Journals (Sweden)

    Daniel Ramos

    2017-02-01

    Full Text Available Data to which the authors refer to throughout this article are likelihood ratios (LR computed from the comparison of 5–12 minutiae fingermarks with fingerprints. These LRs data are used for the validation of a likelihood ratio (LR method in forensic evidence evaluation. These data present a necessary asset for conducting validation experiments when validating LR methods used in forensic evidence evaluation and set up validation reports. These data can be also used as a baseline for comparing the fingermark evidence in the same minutiae configuration as presented in (D. Meuwly, D. Ramos, R. Haraksim, [1], although the reader should keep in mind that different feature extraction algorithms and different AFIS systems used may produce different LRs values. Moreover, these data may serve as a reproducibility exercise, in order to train the generation of validation reports of forensic methods, according to [1]. Alongside the data, a justification and motivation for the use of methods is given. These methods calculate LRs from the fingerprint/mark data and are subject to a validation procedure. The choice of using real forensic fingerprint in the validation and simulated data in the development is described and justified. Validation criteria are set for the purpose of validation of the LR methods, which are used to calculate the LR values from the data and the validation report. For privacy and data protection reasons, the original fingerprint/mark images cannot be shared. But these images do not constitute the core data for the validation, contrarily to the LRs that are shared.

  12. Method for Pre-Conditioning a Measured Surface Height Map for Model Validation

    Science.gov (United States)

    Sidick, Erkin

    2012-01-01

    This software allows one to up-sample or down-sample a measured surface map for model validation, not only without introducing any re-sampling errors, but also eliminating the existing measurement noise and measurement errors. Because the re-sampling of a surface map is accomplished based on the analytical expressions of Zernike-polynomials and a power spectral density model, such re-sampling does not introduce any aliasing and interpolation errors as is done by the conventional interpolation and FFT-based (fast-Fourier-transform-based) spatial-filtering method. Also, this new method automatically eliminates the measurement noise and other measurement errors such as artificial discontinuity. The developmental cycle of an optical system, such as a space telescope, includes, but is not limited to, the following two steps: (1) deriving requirements or specs on the optical quality of individual optics before they are fabricated through optical modeling and simulations, and (2) validating the optical model using the measured surface height maps after all optics are fabricated. There are a number of computational issues related to model validation, one of which is the "pre-conditioning" or pre-processing of the measured surface maps before using them in a model validation software tool. This software addresses the following issues: (1) up- or down-sampling a measured surface map to match it with the gridded data format of a model validation tool, and (2) eliminating the surface measurement noise or measurement errors such that the resulted surface height map is continuous or smoothly-varying. So far, the preferred method used for re-sampling a surface map is two-dimensional interpolation. The main problem of this method is that the same pixel can take different values when the method of interpolation is changed among the different methods such as the "nearest," "linear," "cubic," and "spline" fitting in Matlab. The conventional, FFT-based spatial filtering method used to

  13. Reliability and validity of a brief method to assess nociceptive flexion reflex (NFR) threshold.

    Science.gov (United States)

    Rhudy, Jamie L; France, Christopher R

    2011-07-01

    The nociceptive flexion reflex (NFR) is a physiological tool to study spinal nociception. However, NFR assessment can take several minutes and expose participants to repeated suprathreshold stimulations. The 4 studies reported here assessed the reliability and validity of a brief method to assess NFR threshold that uses a single ascending series of stimulations (Peak 1 NFR), by comparing it to a well-validated method that uses 3 ascending/descending staircases of stimulations (Staircase NFR). Correlations between the NFR definitions were high, were on par with test-retest correlations of Staircase NFR, and were not affected by participant sex or chronic pain status. Results also indicated the test-retest reliabilities for the 2 definitions were similar. Using larger stimulus increments (4 mAs) to assess Peak 1 NFR tended to result in higher NFR threshold estimates than using the Staircase NFR definition, whereas smaller stimulus increments (2 mAs) tended to result in lower NFR threshold estimates than the Staircase NFR definition. Neither NFR definition was correlated with anxiety, pain catastrophizing, or anxiety sensitivity. In sum, a single ascending series of electrical stimulations results in a reliable and valid estimate of NFR threshold. However, caution may be warranted when comparing NFR thresholds across studies that differ in the ascending stimulus increments. This brief method to assess NFR threshold is reliable and valid; therefore, it should be useful to clinical pain researchers interested in quickly assessing inter- and intra-individual differences in spinal nociceptive processes. Copyright © 2011 American Pain Society. Published by Elsevier Inc. All rights reserved.

  14. Human Factors methods concerning integrated validation of nuclear power plant control rooms

    International Nuclear Information System (INIS)

    Oskarsson, Per-Anders; Johansson, Bjoern J.E.; Gonzalez, Natalia

    2010-02-01

    The frame of reference for this work was existing recommendations and instructions from the NPP area, experiences from the review of the Turbic Validation and experiences from system validations performed at the Swedish Armed Forces, e.g. concerning military control rooms and fighter pilots. These enterprises are characterized by complex systems in extreme environments, often with high risks, where human error can lead to serious consequences. A focus group has been performed with representatives responsible for Human Factors issues from all Swedish NPP:s. The questions that were discussed were, among other things, for whom an integrated validation (IV) is performed and its purpose, what should be included in an IV, the comparison with baseline measures, the design process, the role of SSM, which methods of measurement should be used, and how the methods are affected of changes in the control room. The report brings different questions to discussion concerning the validation process. Supplementary methods of measurement for integrated validation are discussed, e.g. dynamic, psychophysiological, and qualitative methods for identification of problems. Supplementary methods for statistical analysis are presented. The study points out a number of deficiencies in the validation process, e.g. the need of common guidelines for validation and design, criteria for different types of measurements, clarification of the role of SSM, and recommendations for the responsibility of external participants in the validation process. The authors propose 12 measures for taking care of the identified problems

  15. Validation of quantitative method for azoxystrobin residues in green beans and peas.

    Science.gov (United States)

    Abdelraheem, Ehab M H; Hassan, Sayed M; Arief, Mohamed M H; Mohammad, Somaia G

    2015-09-01

    This study presents a method validation for extraction and quantitative analysis of azoxystrobin residues in green beans and peas using HPLC-UV and the results confirmed by GC-MS. The employed method involved initial extraction with acetonitrile after the addition of salts (magnesium sulfate and sodium chloride), followed by a cleanup step by activated neutral carbon. Validation parameters; linearity, matrix effect, LOQ, specificity, trueness and repeatability precision were attained. The spiking levels for the trueness and the precision experiments were (0.1, 0.5, 3 mg/kg). For HPLC-UV analysis, mean recoveries ranged between 83.69% to 91.58% and 81.99% to 107.85% for green beans and peas, respectively. For GC-MS analysis, mean recoveries ranged from 76.29% to 94.56% and 80.77% to 100.91% for green beans and peas, respectively. According to these results, the method has been proven to be efficient for extraction and determination of azoxystrobin residues in green beans and peas. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Validation of calculational methods for nuclear criticality safety - approved 1975

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    The American National Standard for Nuclear Criticality Safety in Operations with Fissionable Materials Outside Reactors, N16.1-1975, states in 4.2.5: In the absence of directly applicable experimental measurements, the limits may be derived from calculations made by a method shown to be valid by comparison with experimental data, provided sufficient allowances are made for uncertainties in the data and in the calculations. There are many methods of calculation which vary widely in basis and form. Each has its place in the broad spectrum of problems encountered in the nuclear criticality safety field; however, the general procedure to be followed in establishing validity is common to all. The standard states the requirements for establishing the validity and area(s) of applicability of any calculational method used in assessing nuclear criticality safety

  17. Development and validation of a dissolution method using HPLC for diclofenac potassium in oral suspension

    Directory of Open Access Journals (Sweden)

    Alexandre Machado Rubim

    2014-04-01

    Full Text Available The present study describes the development and validation of an in vitro dissolution method for evaluation to release diclofenac potassium in oral suspension. The dissolution test was developed and validated according to international guidelines. Parameters like linearity, specificity, precision and accuracy were evaluated, as well as the influence of rotation speed and surfactant concentration on the medium. After selecting the best conditions, the method was validated using apparatus 2 (paddle, 50-rpm rotation speed, 900 mL of water with 0.3% sodium lauryl sulfate (SLS as dissolution medium at 37.0 ± 0.5°C. Samples were analyzed using the HPLC-UV (PDA method. The results obtained were satisfactory for the parameters evaluated. The method developed may be useful in routine quality control for pharmaceutical industries that produce oral suspensions containing diclofenac potassium.

  18. Validation method for determination of cholesterol in human urine with electrochemical sensors using gold electrodes

    Science.gov (United States)

    Riyanto, Laksono, Tomy Agung

    2017-12-01

    Electrochemical sensors for the determination of cholesterol with Au as a working electrode (Au) and its application to the analysis of urine have been done. The gold electrode was prepared using gold pure (99.99%), with size 1.0 mm by length and wide respectively, connected with silver wire using silver conductive paint. Validation methods have been investigated in the analysis of cholesterol in human urine using electrochemical sensors or cyclic voltammetry (CV) method. The effect of electrolyte and uric acid concentration has been determined to produce the optimum method. Validation method parameters for cholesterol analysis in human urine using CV are precision, recovery, linearity, limit of detection (LOD) and limit of quantification (LOQ). The result showed the correlation of concentration of cholesterol to anodic peak current is the coefficient determination of R2 = 0.916. The results of the validation method showed the precision, recovery, linearity, LOD, and LOQ are 1.2539%, 144.33%, 0.916, 1.49 × 10-1 mM and 4.96 × 10-1 mM, respectively. As a conclusion is Au electrode is a good electrode for electrochemical sensors to determination of cholesterol in human urine.

  19. Validation of a same-day real-time PCR method for screening of meat and carcass swabs for Salmonella

    Science.gov (United States)

    2009-01-01

    Background One of the major sources of human Salmonella infections is meat. Therefore, efficient and rapid monitoring of Salmonella in the meat production chain is necessary. Validation of alternative methods is needed to prove that the performance is equal to established methods. Very few of the published PCR methods for Salmonella have been validated in collaborative studies. This study describes a validation including comparative and collaborative trials, based on the recommendations from the Nordic organization for validation of alternative microbiological methods (NordVal) of a same-day, non-commercial real-time PCR method for detection of Salmonella in meat and carcass swabs. Results The comparative trial was performed against a reference method (NMKL-71:5, 1999) using artificially and naturally contaminated samples (60 minced veal and pork meat samples, 60 poultry neck-skins, and 120 pig carcass swabs). The relative accuracy was 99%, relative detection level 100%, relative sensitivity 103% and relative specificity 100%. The collaborative trial included six laboratories testing minced meat, poultry neck-skins, and carcass swabs as un-inoculated samples and samples artificially contaminated with 1–10 CFU/25 g, and 10–100 CFU/25 g. Valid results were obtained from five of the laboratories and used for the statistical analysis. Apart from one of the non-inoculated samples being false positive with PCR for one of the laboratories, no false positive or false negative results were reported. Partly based on results obtained in this study, the method has obtained NordVal approval for analysis of Salmonella in meat and carcass swabs. The PCR method was transferred to a production laboratory and the performance was compared with the BAX Salmonella test on 39 pork samples artificially contaminated with Salmonella. There was no significant difference in the results obtained by the two methods. Conclusion The real-time PCR method for detection of Salmonella in meat

  20. Ecological content validation of the Information Assessment Method for parents (IAM-parent): A mixed methods study.

    Science.gov (United States)

    Bujold, M; El Sherif, R; Bush, P L; Johnson-Lafleur, J; Doray, G; Pluye, P

    2018-02-01

    This mixed methods study content validated the Information Assessment Method for parents (IAM-parent) that allows users to systematically rate and comment on online parenting information. Quantitative data and results: 22,407 IAM ratings were collected; of the initial 32 items, descriptive statistics showed that 10 had low relevance. Qualitative data and results: IAM-based comments were collected, and 20 IAM users were interviewed (maximum variation sample); the qualitative data analysis assessed the representativeness of IAM items, and identified items with problematic wording. Researchers, the program director, and Web editors integrated quantitative and qualitative results, which led to a shorter and clearer IAM-parent. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Validation of methods for the determination of radium in waters and soil

    International Nuclear Information System (INIS)

    Decaillon, J.-G.; Bickel, M.; Hill, C.; Altzitzoglou, T.

    2004-01-01

    This article describes the advantages and disadvantages of several analytical methods used to prepare the alpha-particle source. As a result of this study, a new method combining commercial extraction and ion chromatography prior to a final co-precipitation step is proposed. This method has been applied and validated on several matrices (soil, waters) in the framework of international intercomparisons. The integration of this method in a global procedure to analyze actinoids and radium from a single solution (or digested soil) is also described

  2. Method Development and Validation for the Determination of Caffeine: An Alkaloid from Coffea arabica by High-performance Liquid Chromatography Method.

    Science.gov (United States)

    Naveen, P; Lingaraju, H B; Deepak, M; Medhini, B; Prasad, K Shyam

    2018-01-01

    The present study was investigated to develop and validate a reversed phase high performance liquid chromatography method for the determination of caffeine from bean material of Coffee arabica. The separation was achieved on a reversed-phase C18 column using a mobile phase composed of water: methanol (50:50) at a flow rate of 1.0 mlmin-1. The detection was carried out on a UV detector at 272 nm. The developed method was validated according to the requirements for International Conference on Harmonisation (ICH) guidelines, which includes specificity, linearity, precision, accuracy, limit of detection and limit of quantitation. The developed method validates good linearity with excellent correlation coefficient (R2 > 0.999). In repeatability and intermediate precision, the percentage relative standard deviation (% RSD) of peak area was less than 1% shows high precision of the method. The recovery rate for caffeine was within 98.78% - 101.28% indicates high accuracy of the method. The low limit of detection and limit of quantitation of caffeine enable the detection and quantitation of caffeine from C. arabica at low concentrations. The developed HPLC method is a simple, rapid, precisely, accurately and widely accepted and it is recommended for efficient assays in routine work. A simple, accurate, and sensitive high-performance liquid chromatography (HPLC) method for caffeine from Coffea arabica has been developed and validated. The developed HPLC method was validated for linearity, specificity, precision, recovery, limits of detection, and limits of quantification by the International Conference on Harmonization guidelines. The results revealed that the proposed method is highly reliable. This method could be successfully applied for routine quality work analysis. Abbreviation Used: C. arabica : Coffee arabica, ICH: International Conference on Harmonisation, % RSD: Percentage Relative Standard Deviation, R2: Correlation Coefficient, ppm: Parts per million, LOD: Limits

  3. Uncertainty estimates of purity measurements based on current information: toward a "live validation" of purity methods.

    Science.gov (United States)

    Apostol, Izydor; Kelner, Drew; Jiang, Xinzhao Grace; Huang, Gang; Wypych, Jette; Zhang, Xin; Gastwirt, Jessica; Chen, Kenneth; Fodor, Szilan; Hapuarachchi, Suminda; Meriage, Dave; Ye, Frank; Poppe, Leszek; Szpankowski, Wojciech

    2012-12-01

    To predict precision and other performance characteristics of chromatographic purity methods, which represent the most widely used form of analysis in the biopharmaceutical industry. We have conducted a comprehensive survey of purity methods, and show that all performance characteristics fall within narrow measurement ranges. This observation was used to develop a model called Uncertainty Based on Current Information (UBCI), which expresses these performance characteristics as a function of the signal and noise levels, hardware specifications, and software settings. We applied the UCBI model to assess the uncertainty of purity measurements, and compared the results to those from conventional qualification. We demonstrated that the UBCI model is suitable to dynamically assess method performance characteristics, based on information extracted from individual chromatograms. The model provides an opportunity for streamlining qualification and validation studies by implementing a "live validation" of test results utilizing UBCI as a concurrent assessment of measurement uncertainty. Therefore, UBCI can potentially mitigate the challenges associated with laborious conventional method validation and facilitates the introduction of more advanced analytical technologies during the method lifecycle.

  4. Moving beyond Traditional Methods of Survey Validation

    Science.gov (United States)

    Maul, Andrew

    2017-01-01

    In his focus article, "Rethinking Traditional Methods of Survey Validation," published in this issue of "Measurement: Interdisciplinary Research and Perspectives," Andrew Maul wrote that it is commonly believed that self-report, survey-based instruments can be used to measure a wide range of psychological attributes, such as…

  5. Validation Process Methods

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, John E. [National Renewable Energy Lab. (NREL), Golden, CO (United States); English, Christine M. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gesick, Joshua C. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mukkamala, Saikrishna [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2018-01-04

    This report documents the validation process as applied to projects awarded through Funding Opportunity Announcements (FOAs) within the U.S. Department of Energy Bioenergy Technologies Office (DOE-BETO). It describes the procedures used to protect and verify project data, as well as the systematic framework used to evaluate and track performance metrics throughout the life of the project. This report also describes the procedures used to validate the proposed process design, cost data, analysis methodologies, and supporting documentation provided by the recipients.

  6. Probability of identification: a statistical model for the validation of qualitative botanical identification methods.

    Science.gov (United States)

    LaBudde, Robert A; Harnly, James M

    2012-01-01

    A qualitative botanical identification method (BIM) is an analytical procedure that returns a binary result (1 = Identified, 0 = Not Identified). A BIM may be used by a buyer, manufacturer, or regulator to determine whether a botanical material being tested is the same as the target (desired) material, or whether it contains excessive nontarget (undesirable) material. The report describes the development and validation of studies for a BIM based on the proportion of replicates identified, or probability of identification (POI), as the basic observed statistic. The statistical procedures proposed for data analysis follow closely those of the probability of detection, and harmonize the statistical concepts and parameters between quantitative and qualitative method validation. Use of POI statistics also harmonizes statistical concepts for botanical, microbiological, toxin, and other analyte identification methods that produce binary results. The POI statistical model provides a tool for graphical representation of response curves for qualitative methods, reporting of descriptive statistics, and application of performance requirements. Single collaborator and multicollaborative study examples are given.

  7. Results from the First Validation Phase of CAP code

    International Nuclear Information System (INIS)

    Choo, Yeon Joon; Hong, Soon Joon; Hwang, Su Hyun; Kim, Min Ki; Lee, Byung Chul; Ha, Sang Jun; Choi, Hoon

    2010-01-01

    The second stage of Safety Analysis Code Development for Nuclear Power Plants was lunched on Apirl, 2010 and is scheduled to be through 2012, of which the scope of work shall cover from code validation to licensing preparation. As a part of this project, CAP(Containment Analysis Package) will follow the same procedures. CAP's validation works are organized hieratically into four validation steps using; 1) Fundamental phenomena. 2) Principal phenomena (mixing and transport) and components in containment. 3) Demonstration test by small, middle, large facilities and International Standard Problems. 4) Comparison with other containment codes such as GOTHIC or COMTEMPT. In addition, collecting the experimental data related to containment phenomena and then constructing the database is one of the major works during the second stage as a part of this project. From the validation process of fundamental phenomenon, it could be expected that the current capability and the future improvements of CAP code will be revealed. For this purpose, simple but significant problems, which have the exact analytical solution, were selected and calculated for validation of fundamental phenomena. In this paper, some results of validation problems for the selected fundamental phenomena will be summarized and discussed briefly

  8. A method for the statistical interpretation of friction ridge skin impression evidence: Method development and validation.

    Science.gov (United States)

    Swofford, H J; Koertner, A J; Zemp, F; Ausdemore, M; Liu, A; Salyards, M J

    2018-04-03

    The forensic fingerprint community has faced increasing amounts of criticism by scientific and legal commentators, challenging the validity and reliability of fingerprint evidence due to the lack of an empirically demonstrable basis to evaluate and report the strength of the evidence in a given case. This paper presents a method, developed as a stand-alone software application, FRStat, which provides a statistical assessment of the strength of fingerprint evidence. The performance was evaluated using a variety of mated and non-mated datasets. The results show strong performance characteristics, often with values supporting specificity rates greater than 99%. This method provides fingerprint experts the capability to demonstrate the validity and reliability of fingerprint evidence in a given case and report the findings in a more transparent and standardized fashion with clearly defined criteria for conclusions and known error rate information thereby responding to concerns raised by the scientific and legal communities. Published by Elsevier B.V.

  9. Development and Validation of High Performance Liquid Chromatography Method for Determination Atorvastatin in Tablet

    Science.gov (United States)

    Yugatama, A.; Rohmani, S.; Dewangga, A.

    2018-03-01

    Atorvastatin is the primary choice for dyslipidemia treatment. Due to patent expiration of atorvastatin, the pharmaceutical industry makes copy of the drug. Therefore, the development methods for tablet quality tests involving atorvastatin concentration on tablets needs to be performed. The purpose of this research was to develop and validate the simple atorvastatin tablet analytical method by HPLC. HPLC system used in this experiment consisted of column Cosmosil C18 (150 x 4,6 mm, 5 µm) as the stationary reverse phase chomatography, a mixture of methanol-water at pH 3 (80:20 v/v) as the mobile phase, flow rate of 1 mL/min, and UV detector at wavelength of 245 nm. Validation methods were including: selectivity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). The results of this study indicate that the developed method had good validation including selectivity, linearity, accuracy, precision, LOD, and LOQ for analysis of atorvastatin tablet content. LOD and LOQ were 0.2 and 0.7 ng/mL, and the linearity range were 20 - 120 ng/mL.

  10. Validation of the k0 standardization method in neutron activation analysis

    International Nuclear Information System (INIS)

    Kubesova, Marie

    2009-01-01

    The goal of this work was to validate the k 0 standardization method in neutron activation analysis for use by the Nuclear Physics Institute's NAA Laboratory. The precision and accuracy of the method were examined by using two types of reference materials: the one type comprised a set of synthetic materials and served to check the implementation of k 0 standardization, the other type consisted of matrix NIST SRMs comprising various different matrices. In general, a good agreement was obtained between the results of this work and the certified values, giving evidence of the accuracy of our results. In addition, the limits were evaluated for 61 elements

  11. Validation of Alternative In Vitro Methods to Animal Testing: Concepts, Challenges, Processes and Tools.

    Science.gov (United States)

    Griesinger, Claudius; Desprez, Bertrand; Coecke, Sandra; Casey, Warren; Zuang, Valérie

    This chapter explores the concepts, processes, tools and challenges relating to the validation of alternative methods for toxicity and safety testing. In general terms, validation is the process of assessing the appropriateness and usefulness of a tool for its intended purpose. Validation is routinely used in various contexts in science, technology, the manufacturing and services sectors. It serves to assess the fitness-for-purpose of devices, systems, software up to entire methodologies. In the area of toxicity testing, validation plays an indispensable role: "alternative approaches" are increasingly replacing animal models as predictive tools and it needs to be demonstrated that these novel methods are fit for purpose. Alternative approaches include in vitro test methods, non-testing approaches such as predictive computer models up to entire testing and assessment strategies composed of method suites, data sources and decision-aiding tools. Data generated with alternative approaches are ultimately used for decision-making on public health and the protection of the environment. It is therefore essential that the underlying methods and methodologies are thoroughly characterised, assessed and transparently documented through validation studies involving impartial actors. Importantly, validation serves as a filter to ensure that only test methods able to produce data that help to address legislative requirements (e.g. EU's REACH legislation) are accepted as official testing tools and, owing to the globalisation of markets, recognised on international level (e.g. through inclusion in OECD test guidelines). Since validation creates a credible and transparent evidence base on test methods, it provides a quality stamp, supporting companies developing and marketing alternative methods and creating considerable business opportunities. Validation of alternative methods is conducted through scientific studies assessing two key hypotheses, reliability and relevance of the

  12. Internal consistency and validity of an observational method for assessing disability in mobility in patients with osteoarthritis.

    NARCIS (Netherlands)

    Steultjens, M.P.M.; Dekker, J.; Baar, M.E. van; Oostendorp, R.A.B.; Bijlsma, J.W.J.

    1999-01-01

    Objective: To establish the internal consistency of validity of an observational method for assessing diasbility in mobility in patients with osteoarthritis (OA), Methods: Data were obtained from 198 patients with OA of the hip or knee. Results of the observational method were compared with results

  13. The use of Geographic Information System (GIS) and non-GIS methods to assess the external validity of samples postcollection.

    Science.gov (United States)

    Richardson, Esther; Good, Margaret; McGrath, Guy; More, Simon J

    2009-09-01

    External validity is fundamental to veterinary diagnostic investigation, reflecting the accuracy with which sample results can be extrapolated to a broader population of interest. Probability sampling methods are routinely used during the collection of samples from populations, specifically to maximize external validity. Nonprobability sampling (e.g., of blood samples collected as part of routine surveillance programs or laboratory submissions) may provide useful data for further posthoc epidemiological analysis, adding value to the collection and submission of samples. As the sample has already been submitted, the analyst or investigator does not have any control over the sampling methodology, and hence external validity as routine probability sampling methods may not have been employed. The current study describes several Geographic Information System (GIS) and non-GIS methods, applied posthoc, to assess the external validity of samples collected using both probability and nonprobability sampling methods. These methods could equally be employed for inspecting other datasets. Mapping was conducted using ArcView 9.1. Based on this posthoc assessment, results from the random field sample could provide an externally valid, albeit relatively imprecise, estimate of national disease prevalence, of disease prevalence in 3 of the 4 provinces (all but Ulster, in the north and northwest, where sample size was small), and in beef and dairy herds. This study provides practical methods for examining the external validity of samples postcollection.

  14. A Component-Based Modeling and Validation Method for PLC Systems

    Directory of Open Access Journals (Sweden)

    Rui Wang

    2014-05-01

    Full Text Available Programmable logic controllers (PLCs are complex embedded systems that are widely used in industry. This paper presents a component-based modeling and validation method for PLC systems using the behavior-interaction-priority (BIP framework. We designed a general system architecture and a component library for a type of device control system. The control software and hardware of the environment were all modeled as BIP components. System requirements were formalized as monitors. Simulation was carried out to validate the system model. A realistic example from industry of the gates control system was employed to illustrate our strategies. We found a couple of design errors during the simulation, which helped us to improve the dependability of the original systems. The results of experiment demonstrated the effectiveness of our approach.

  15. Determination of Modafinil in Tablet Formulation Using Three New Validated Spectrophotometric Methods

    International Nuclear Information System (INIS)

    Basniwal, P.K.; Jain, D.; Basniwal, P.K.

    2014-01-01

    In this study, three new UV spectrophotometric methods viz. linear regression equation (LRE), standard absorptivity (SA) and first order derivative (FOD) method were developed and validated for determination of modafinil in tablet form. The Beer-Lamberts law was obeyed as linear in the range of 10-50 μg/ mL and all the methods were validated for linearity, accuracy, precision and robustness. These methods were successfully applied for assay of modafinil drug content in tablets in the range of 100.20 - 100.42 %, 100.11 - 100.58 % and 100.25 - 100.34 %, respectively with acceptable standard deviation (less than two) for all the methods. The validated spectrophotometric methods may be successfully applied for assay, dissolution studies, bio-equivalence studies as well as routine analysis in pharmaceutical industries. (author)

  16. An Engineering Method of Civil Jet Requirements Validation Based on Requirements Project Principle

    Science.gov (United States)

    Wang, Yue; Gao, Dan; Mao, Xuming

    2018-03-01

    A method of requirements validation is developed and defined to meet the needs of civil jet requirements validation in product development. Based on requirements project principle, this method will not affect the conventional design elements, and can effectively connect the requirements with design. It realizes the modern civil jet development concept, which is “requirement is the origin, design is the basis”. So far, the method has been successfully applied in civil jet aircraft development in China. Taking takeoff field length as an example, the validation process and the validation method of the requirements are detailed introduced in the study, with the hope of providing the experiences to other civil jet product design.

  17. ValidatorDB: database of up-to-date validation results for ligands and non-standard residues from the Protein Data Bank.

    Science.gov (United States)

    Sehnal, David; Svobodová Vařeková, Radka; Pravda, Lukáš; Ionescu, Crina-Maria; Geidl, Stanislav; Horský, Vladimír; Jaiswal, Deepti; Wimmerová, Michaela; Koča, Jaroslav

    2015-01-01

    Following the discovery of serious errors in the structure of biomacromolecules, structure validation has become a key topic of research, especially for ligands and non-standard residues. ValidatorDB (freely available at http://ncbr.muni.cz/ValidatorDB) offers a new step in this direction, in the form of a database of validation results for all ligands and non-standard residues from the Protein Data Bank (all molecules with seven or more heavy atoms). Model molecules from the wwPDB Chemical Component Dictionary are used as reference during validation. ValidatorDB covers the main aspects of validation of annotation, and additionally introduces several useful validation analyses. The most significant is the classification of chirality errors, allowing the user to distinguish between serious issues and minor inconsistencies. Other such analyses are able to report, for example, completely erroneous ligands, alternate conformations or complete identity with the model molecules. All results are systematically classified into categories, and statistical evaluations are performed. In addition to detailed validation reports for each molecule, ValidatorDB provides summaries of the validation results for the entire PDB, for sets of molecules sharing the same annotation (three-letter code) or the same PDB entry, and for user-defined selections of annotations or PDB entries. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.

  18. The Validation of AAN Method Used by Rock Sample SRM 2780

    International Nuclear Information System (INIS)

    Rina Mulyaningsih, Th.

    2004-01-01

    AAN methods is a non standard testing method. The testing laboratory must be validate its using method to ensure and confirm that it is suitable with application. The analysis of SRM 2780 Hard rock mine waste with 9 replicates has been done to test the accuracy of AAN methods. The result showed that the elements As, Ba, Mn, V, Zn and Na have good accuration were evaluated against the acceptance criteria for accuracy with confidence level 95 %. The elements As, Co, Sc, Cr, Ba, Sb, Cs, Mn, V, Au, Zn and Na have low relative bias between the analyst's value and the target value. The continued testing must be done to test the accuracy of another certificated elements. (author)

  19. Development and Validation of a Stability-Indicating LC-UV Method ...

    African Journals Online (AJOL)

    Keywords: Ketotifen, Cetirizine, Stability indicating method, Stressed conditions, Validation. Tropical ... in biological fluids [13] are also reported. Stability indicating HPLC method is reported for ketotifen where drug is ..... paracetamol, cetirizine.

  20. Validation of analytical methods for the stability studies of naproxen suppositories for infant and adult use

    International Nuclear Information System (INIS)

    Rodriguez Hernandez, Yaslenis; Suarez Perez, Yania; Garcia Pulpeiro, Oscar

    2011-01-01

    Analytical and validating studies were performed in this paper, with a view to using them in the stability studies of the future formulations of naproxen suppositories for children and adults. The most influential factors in the naproxen stability were determined, that is, the major degradation occurred in acid medium, oxidative medium and by light action. One high-performance liquid chromatography-based method was evaluated, which proved to be adequate to quantify naproxen in suppositories and was selective against degradation products. The quantification limit was 3,480 μg, so it was valid for these studies. Additionally, the parameters specificity for stability, detection and quantification limits were evaluated for the direct semi-aqueous acid-base method, which was formerly validated for the quality control and showed satisfactory results. Nevertheless, the volumetric methods were not regarded as stability indicators; therefore, this method will be used along with the chromatographic methods of choice, that is, thin-layer chromatography and highperformance liquid chromatography, to determine the degradation products

  1. A long-term validation of the modernised DC-ARC-OES solid-sample method.

    Science.gov (United States)

    Flórián, K; Hassler, J; Förster, O

    2001-12-01

    The validation procedure based on ISO 17025 standard has been used to study and illustrate both the longterm stability of the calibration process of the DC-ARC solid sample spectrometric method and the main validation criteria of the method. In the calculation of the validation characteristics depending on the linearity(calibration), also the fulfilment of predetermining criteria such as normality and homoscedasticity was checked. In order to decide whether there are any trends in the time-variation of the analytical signal or not, also the Neumann test of trend was applied and evaluated. Finally, a comparison with similar validation data of the ETV-ICP-OES method was carried out.

  2. Reliability and validity of the AutoCAD software method in lumbar lordosis measurement.

    Science.gov (United States)

    Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe

    2011-12-01

    The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis.

  3. AOAC Official MethodSM Matrix Extension Validation Study of Assurance GDSTM for the Detection of Salmonella in Selected Spices.

    Science.gov (United States)

    Feldsine, Philip; Kaur, Mandeep; Shah, Khyati; Immerman, Amy; Jucker, Markus; Lienau, Andrew

    2015-01-01

    Assurance GDSTM for Salmonella Tq has been validated according to the AOAC INTERNATIONAL Methods Committee Guidelines for Validation of Microbiological Methods for Food and Environmental Surfaces for the detection of selected foods and environmental surfaces (Official Method of AnalysisSM 2009.03, Performance Tested MethodSM No. 050602). The method also completed AFNOR validation (following the ISO 16140 standard) compared to the reference method EN ISO 6579. For AFNOR, GDS was given a scope covering all human food, animal feed stuff, and environmental surfaces (Certificate No. TRA02/12-01/09). Results showed that Assurance GDS for Salmonella (GDS) has high sensitivity and is equivalent to the reference culture methods for the detection of motile and non-motile Salmonella. As part of the aforementioned validations, inclusivity and exclusivity studies, stability, and ruggedness studies were also conducted. Assurance GDS has 100% inclusivity and exclusivity among the 100 Salmonella serovars and 35 non-Salmonella organisms analyzed. To add to the scope of the Assurance GDS for Salmonella method, a matrix extension study was conducted, following the AOAC guidelines, to validate the application of the method for selected spices, specifically curry powder, cumin powder, and chili powder, for the detection of Salmonella.

  4. Validation Techniques of network harmonic models based on switching of a series linear component and measuring resultant harmonic increments

    DEFF Research Database (Denmark)

    Wiechowski, Wojciech Tomasz; Lykkegaard, Jan; Bak, Claus Leth

    2007-01-01

    In this paper two methods of validation of transmission network harmonic models are introduced. The methods were developed as a result of the work presented in [1]. The first method allows calculating the transfer harmonic impedance between two nodes of a network. Switching a linear, series network......, as for example a transmission line. Both methods require that harmonic measurements performed at two ends of the disconnected element are precisely synchronized....... are used for calculation of the transfer harmonic impedance between the nodes. The determined transfer harmonic impedance can be used to validate a computer model of the network. The second method is an extension of the fist one. It allows switching a series element that contains a shunt branch...

  5. Validity in Mixed Methods Research in Education: The Application of Habermas' Critical Theory

    Science.gov (United States)

    Long, Haiying

    2017-01-01

    Mixed methods approach has developed into the third methodological movement in educational research. Validity in mixed methods research as an important issue, however, has not been examined as extensively as that of quantitative and qualitative research. Additionally, the previous discussions of validity in mixed methods research focus on research…

  6. A Validated, Rapid HPLC-ESI-MS/MS Method for the Determination of Lycopsamine.

    Science.gov (United States)

    Jedlinszki, Nikoletta; Csupor, Dezső

    2015-07-01

    The aim of the present work was to develop and validate an HPLC-MS/MS method for the determination of a major pyrrolizidine alkaloid of comfrey (lycopsamine) in aqueous samples as a basis for the development of a method for the determination of absorption of lycopsamine by human skin. A linear calibration curve was established in the range of 1.32-440 ng. The intraday precision during the 3-day validation period ranged between 0.57 and 2.48% while the interday precision was 1.70% and 1.95% for quality control samples. LOD was 0.014 ng and recovery was above 97%. The lycopsamine content of the samples stored for 9 and 25 days at 22 degrees C, 10 degrees C and -25 degrees C did not vary. These results underline the good repeatability and accuracy of our method and allow the analysis of samples with very low lycopsamine content.

  7. Method of administration of PROMIS scales did not significantly impact score level, reliability, or validity

    DEFF Research Database (Denmark)

    Bjorner, Jakob B; Rose, Matthias; Gandek, Barbara

    2014-01-01

    OBJECTIVES: To test the impact of the method of administration (MOA) on score level, reliability, and validity of scales developed in the Patient Reported Outcomes Measurement Information System (PROMIS). STUDY DESIGN AND SETTING: Two nonoverlapping parallel forms each containing eight items from......, no significant mode differences were found and all confidence intervals were within the prespecified minimal important difference of 0.2 standard deviation. Parallel-forms reliabilities were very high (ICC = 0.85-0.93). Only one across-mode ICC was significantly lower than the same-mode ICC. Tests of validity...... questionnaire (PQ), personal digital assistant (PDA), or personal computer (PC) and a second form by PC, in the same administration. Method equivalence was evaluated through analyses of difference scores, intraclass correlations (ICCs), and convergent/discriminant validity. RESULTS: In difference score analyses...

  8. Development and validation of stability indicating UPLC assay method for ziprasidone active pharma ingredient

    Directory of Open Access Journals (Sweden)

    Sonam Mittal

    2012-01-01

    Full Text Available Background: Ziprasidone, a novel antipsychotic, exhibits a potent highly selective antagonistic activity on D2 and 5HT2A receptors. Literature survey for ziprasidone revealed several analytical methods based on different techniques but no UPLC method has been reported so far. Aim: Aim of this research paper is to present a simple and rapid stability indicating isocratic, ultra performance liquid chromatographic (UPLC method which was developed and validated for the determination of ziprasidone active pharmaceutical ingredient. Forced degradation studies of ziprasidone were studied under acid, base, oxidative hydrolysis, thermal stress and photo stress conditions. Materials and Methods: The quantitative determination of ziprasidone drug was performed on a Supelco analytical column (100×2.1 mm i.d., 2.7 ΅m with 10 mM ammonium acetate buffer (pH: 6.7 and acetonitrile (ACN as mobile phase with the ratio (55:45-Buffer:ACN at a flow rate of 0.35 ml/ min. For UPLC method, UV detection was made at 318 nm and the run time was 3 min. Developed UPLC method was validated as per ICH guidelines. Results and Conclusion: Mild degradation of the drug substance was observed during oxidative hydrolysis and considerable degradation observed during basic hydrolysis. During method validation, parameters such as precision, linearity, ruggedness, stability, robustness, and specificity were evaluated, which remained within acceptable limits. Developed UPLC method was successfully applied for evaluating assay of Ziprasidone active Pharma ingredient.

  9. Validated RP-HPLC Method for Quantification of Phenolic ...

    African Journals Online (AJOL)

    Purpose: To evaluate the total phenolic content and antioxidant potential of the methanol extracts of aerial parts and roots of Thymus sipyleus Boiss and also to determine some phenolic compounds using a newly developed and validated reversed phase high performance liquid chromatography (RP-HPLC) method.

  10. High-performance liquid chromatography method validation for determination of tetracycline residues in poultry meat

    Directory of Open Access Journals (Sweden)

    Vikas Gupta

    2014-01-01

    Full Text Available Background: In this study, a method for determination of tetracycline (TC residues in poultry with the help of high-performance liquid chromatography technique was validated. Materials and Methods: The principle step involved in ultrasonic-assisted extraction of TCs from poultry samples by 2 ml of 20% trichloroacetic acid and phosphate buffer (pH 4, which gave a clearer supernatant and high recovery, followed by centrifugation and purification by using 0.22 μm filter paper. Results: Validity study of the method revealed that all obtained calibration curves showed good linearity (r2 > 0.999 over the range of 40-4500 ng. Sensitivity was found to be 1.54 and 1.80 ng for oxytetracycline (OTC and TC. Accuracy was in the range of 87.94-96.20% and 72.40-79.84% for meat. Precision was lower than 10% in all cases indicating that the method can be used as a validated method. Limit of detection was found to be 4.8 and 5.10 ng for OTC and TC, respectively. The corresponding values of limit of quantitation were 11 and 12 ng. Conclusion: The method reliably identifies and quantifies the selected TC and OTC in the reconstituted poultry meat in the low and sub-nanogram range and can be applied in any laboratory.

  11. Development and Validation of a Bioanalytical Method for Direct ...

    African Journals Online (AJOL)

    Purpose: To develop and validate a user-friendly spiked plasma method for the extraction of diclofenac potassium that reduces the number of treatments with plasma sample, in order to minimize human error. Method: Instead of solvent evaporation technique, the spiked plasma sample was modified with H2SO4 and NaCl, ...

  12. Results and validity of renal blood flow measurements using Xenon 133

    International Nuclear Information System (INIS)

    Serres, P.; Danet, B.; Guiraud, R.; Durand, D.; Ader, J.L.

    1975-01-01

    The renal blood flow was measured by external recording of the xenon 133 excretion curve. The study involved 45 patients with permanent high blood pressure and 7 transplant patients. The validity of the method was checked on 10 dogs. From the results it seems that the cortical blood flow, its fraction and the mean flow rate are the most representative of the renal haemodynamics parameters, from which may be established the repercussions of blood pressure on kidney vascularisation. Experiments are in progress on animals to check the compartment idea by comparing injections into the renal artery and into various kidney tissues in situ [fr

  13. Rationale and methods of the European Food Consumption Validation (EFCOVAL) Project

    NARCIS (Netherlands)

    Boer, de E.J.; Slimani, N.; Boeing, H.; Feinberg, M.; Leclerq, C.; Trolle, E.; Amiano, P.; Andersen, L.F.; Freisling, H.; Geelen, A.; Harttig, U.; Huybrechts, I.; Kaic-Rak, A.; Lafay, L.; Lillegaard, I.T.L.; Ruprich, J.; Vries, de J.H.M.; Ocke, M.C.

    2011-01-01

    Background/Objectives: The overall objective of the European Food Consumption Validation (EFCOVAL) Project was to further develop and validate a trans-European food consumption method to be used for the evaluation of the intake of foods, nutrients and potentially hazardous chemicals within the

  14. A guideline for the validation of likelihood ratio methods used for forensic evidence evaluation.

    Science.gov (United States)

    Meuwly, Didier; Ramos, Daniel; Haraksim, Rudolf

    2017-07-01

    This Guideline proposes a protocol for the validation of forensic evaluation methods at the source level, using the Likelihood Ratio framework as defined within the Bayes' inference model. In the context of the inference of identity of source, the Likelihood Ratio is used to evaluate the strength of the evidence for a trace specimen, e.g. a fingermark, and a reference specimen, e.g. a fingerprint, to originate from common or different sources. Some theoretical aspects of probabilities necessary for this Guideline were discussed prior to its elaboration, which started after a workshop of forensic researchers and practitioners involved in this topic. In the workshop, the following questions were addressed: "which aspects of a forensic evaluation scenario need to be validated?", "what is the role of the LR as part of a decision process?" and "how to deal with uncertainty in the LR calculation?". The questions: "what to validate?" focuses on the validation methods and criteria and "how to validate?" deals with the implementation of the validation protocol. Answers to these questions were deemed necessary with several objectives. First, concepts typical for validation standards [1], such as performance characteristics, performance metrics and validation criteria, will be adapted or applied by analogy to the LR framework. Second, a validation strategy will be defined. Third, validation methods will be described. Finally, a validation protocol and an example of validation report will be proposed, which can be applied to the forensic fields developing and validating LR methods for the evaluation of the strength of evidence at source level under the following propositions. Copyright © 2016. Published by Elsevier B.V.

  15. Internal consistency and validity of an observational method for assessing disability in mobility in patients with osteoarthritis

    NARCIS (Netherlands)

    Steultjens, M. P.; Dekker, J.; van Baar, M. E.; Oostendorp, R. A.; Bijlsma, J. W.

    1999-01-01

    To establish the internal consistency and validity of an observational method for assessing disability in mobility in patients with osteoarthritis (OA). Data were obtained from 198 patients with OA of the hip or knee. Results of the observational method were compared with results of self-report

  16. Development and Validation of a Liquid Chromatographic Method ...

    African Journals Online (AJOL)

    A liquid chromatographic method for the simultaneous determination of six human immunodeficiency virus (HIV) protease inhibitors, indinavir, saquinavir, ritonavir, amprenavir, nelfinavir and lopinavir, was developed and validated. Optimal separation was achieved on a PLRP-S 100 Å, 250 x 4.6 mm I.D. column maintained ...

  17. Validation of histamine determination Method in yoghurt using High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    M Jahedinia

    2014-02-01

    Full Text Available Biogenic amines are organic, basic nitrogenous compounds of low molecular weight that are mainly generated by the enzymatic decarboxylation of amino acids by microorganisms. Dairy products are among the foods with the highest amine content. A wide variety of methods and procedures for determination of histamine and biogenic amines have been established. Amongst, HPLC method is considered as reference method. The aim of this study was to validate Reversed Phase HPLC method determination of histamine in yoghurt. The mobile phase consisted of acetonitrile/water (18:88 v/v and the flow rate was set at 0.5 ml/min using isocratic HPLC. Detection was carried out at 254 nm using UV-detector. Calibration curve that was constructed using peak area of standards was linear and value of correlation coefficient (r2 was estimated at 0.998. Good recoveries were observed for histamine under investigation at all spiking levels and average of recoveries was 84%. The RSD% value from repeatability test was found to be %4.4. Limit of detection and limit of quantitation were 0.14 and 0.42 µ/ml, respectively. The results of validation tests showed that the method is reliable and rapid for quantification of histamine in yoghurt.

  18. JaCVAM-organized international validation study of the in vivo rodent alkaline comet assay for the detection of genotoxic carcinogens: I. Summary of pre-validation study results.

    Science.gov (United States)

    Uno, Yoshifumi; Kojima, Hajime; Omori, Takashi; Corvi, Raffaella; Honma, Masamistu; Schechtman, Leonard M; Tice, Raymond R; Burlinson, Brian; Escobar, Patricia A; Kraynak, Andrew R; Nakagawa, Yuzuki; Nakajima, Madoka; Pant, Kamala; Asano, Norihide; Lovell, David; Morita, Takeshi; Ohno, Yasuo; Hayashi, Makoto

    2015-07-01

    The in vivo rodent alkaline comet assay (comet assay) is used internationally to investigate the in vivo genotoxic potential of test chemicals. This assay, however, has not previously been formally validated. The Japanese Center for the Validation of Alternative Methods (JaCVAM), with the cooperation of the U.S. NTP Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM)/the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM), the European Centre for the Validation of Alternative Methods (ECVAM), and the Japanese Environmental Mutagen Society/Mammalian Mutagenesis Study Group (JEMS/MMS), organized an international validation study to evaluate the reliability and relevance of the assay for identifying genotoxic carcinogens, using liver and stomach as target organs. The ultimate goal of this validation effort was to establish an Organisation for Economic Co-operation and Development (OECD) test guideline. The purpose of the pre-validation studies (i.e., Phase 1 through 3), conducted in four or five laboratories with extensive comet assay experience, was to optimize the protocol to be used during the definitive validation study. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. FDIR Strategy Validation with the B Method

    Science.gov (United States)

    Sabatier, D.; Dellandrea, B.; Chemouil, D.

    2008-08-01

    In a formation flying satellite system, the FDIR strategy (Failure Detection, Isolation and Recovery) is paramount. When a failure occurs, satellites should be able to take appropriate reconfiguration actions to obtain the best possible results given the failure, ranging from avoiding satellite-to-satellite collision to continuing the mission without disturbance if possible. To achieve this goal, each satellite in the formation has an implemented FDIR strategy that governs how it detects failures (from tests or by deduction) and how it reacts (reconfiguration using redundant equipments, avoidance manoeuvres, etc.). The goal is to protect the satellites first and the mission as much as possible. In a project initiated by the CNES, ClearSy experiments the B Method to validate the FDIR strategies developed by Thales Alenia Space, of the inter satellite positioning and communication devices that will be used for the SIMBOL-X (2 satellite configuration) and the PEGASE (3 satellite configuration) missions and potentially for other missions afterward. These radio frequency metrology sensor devices provide satellite positioning and inter satellite communication in formation flying. This article presents the results of this experience.

  20. MR-based Water Content Estimation in Cartilage: Design and Validation of a Method

    DEFF Research Database (Denmark)

    Shiguetomi Medina, Juan Manuel; Kristiansen, Maja Sofie; Ringgaard, Steffen

    2012-01-01

    Objective Design and validation of an MR-based method that allows the calculation of the water content in cartilage tissue. Material and Methods We modified and adapted to cartilage tissue T1 map based water content MR sequences commonly used in the neurology field. Using a 37 Celsius degree stable...... was costumed and programmed. Finally, we validated the method after measuring and comparing 3 more cartilage samples in a living animal (pig). The obtained data was analyzed and the water content calculated. Then, the same samples were freeze-dried (this technique allows to take out all the water that a tissue...... contains) and we measured the water they contained. Results We could reproduce twice the 37 Celsius degree system and could perform the measurements in a similar way. We found that the MR T1 map based water content sequences can provide information that, after being analyzed with a special software, can...

  1. Determination of methylmercury in marine biota samples with advanced mercury analyzer: method validation.

    Science.gov (United States)

    Azemard, Sabine; Vassileva, Emilia

    2015-06-01

    In this paper, we present a simple, fast and cost-effective method for determination of methyl mercury (MeHg) in marine samples. All important parameters influencing the sample preparation process were investigated and optimized. Full validation of the method was performed in accordance to the ISO-17025 (ISO/IEC, 2005) and Eurachem guidelines. Blanks, selectivity, working range (0.09-3.0ng), recovery (92-108%), intermediate precision (1.7-4.5%), traceability, limit of detection (0.009ng), limit of quantification (0.045ng) and expanded uncertainty (15%, k=2) were assessed. Estimation of the uncertainty contribution of each parameter and the demonstration of traceability of measurement results was provided as well. Furthermore, the selectivity of the method was studied by analyzing the same sample extracts by advanced mercury analyzer (AMA) and gas chromatography-atomic fluorescence spectrometry (GC-AFS). Additional validation of the proposed procedure was effectuated by participation in the IAEA-461 worldwide inter-laboratory comparison exercises. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Empirical Performance of Cross-Validation With Oracle Methods in a Genomics Context.

    Science.gov (United States)

    Martinez, Josue G; Carroll, Raymond J; Müller, Samuel; Sampson, Joshua N; Chatterjee, Nilanjan

    2011-11-01

    When employing model selection methods with oracle properties such as the smoothly clipped absolute deviation (SCAD) and the Adaptive Lasso, it is typical to estimate the smoothing parameter by m-fold cross-validation, for example, m = 10. In problems where the true regression function is sparse and the signals large, such cross-validation typically works well. However, in regression modeling of genomic studies involving Single Nucleotide Polymorphisms (SNP), the true regression functions, while thought to be sparse, do not have large signals. We demonstrate empirically that in such problems, the number of selected variables using SCAD and the Adaptive Lasso, with 10-fold cross-validation, is a random variable that has considerable and surprising variation. Similar remarks apply to non-oracle methods such as the Lasso. Our study strongly questions the suitability of performing only a single run of m-fold cross-validation with any oracle method, and not just the SCAD and Adaptive Lasso.

  3. Acceptability criteria for linear dependence in validating UV-spectrophotometric methods of quantitative determination in forensic and toxicological analysis

    Directory of Open Access Journals (Sweden)

    L. Yu. Klimenko

    2014-08-01

    Full Text Available Introduction. This article is the result of authors’ research in the field of development of the approaches to validation of quantitative determination methods for purposes of forensic and toxicological analysis and devoted to the problem of acceptability criteria formation for validation parameter «linearity/calibration model». The aim of research. The purpose of this paper is to analyse the present approaches to acceptability estimation of the calibration model chosen for method description according to the requirements of the international guidances, to form the own approaches to acceptability estimation of the linear dependence when carrying out the validation of UV-spectrophotometric methods of quantitative determination for forensic and toxicological analysis. Materials and methods. UV-spectrophotometric method of doxylamine quantitative determination in blood. Results. The approaches to acceptability estimation of calibration models when carrying out the validation of bioanalytical methods is stated in international papers, namely «Guidance for Industry: Bioanalytical method validation» (U.S. FDA, 2001, «Standard Practices for Method Validation in Forensic Toxicology» (SWGTOX, 2012, «Guidance for the Validation of Analytical Methodology and Calibration of Equipment used for Testing of Illicit Drugs in Seized Materials and Biological Specimens» (UNODC, 2009 and «Guideline on validation of bioanalytical methods» (ЕМА, 2011 have been analysed. It has been suggested to be guided by domestic developments in the field of validation of analysis methods for medicines and, particularly, by the approaches to validation methods in the variant of the calibration curve method for forming the acceptability criteria of the obtained linear dependences when carrying out the validation of UV-spectrophotometric methods of quantitative determination for forensic and toxicological analysis. The choice of the method of calibration curve is

  4. [Method for evaluating the competence of specialists--the validation of 360-degree-questionnaire].

    Science.gov (United States)

    Nørgaard, Kirsten; Pedersen, Juri; Ravn, Lisbeth; Albrecht-Beste, Elisabeth; Holck, Kim; Fredløv, Maj; Møller, Lars Krag

    2010-04-19

    Assessment of physicians' performance focuses on the quality of their work. The aim of this study was to develop a valid, usable and acceptable multisource feedback assessment tool (MFAT) for hospital consultants. Statements were produced on consultant competencies within non-medical areas like collaboration, professionalism, communication, health promotion, academics and administration. The statements were validated by physicians and later by non-physician professionals after adjustments had been made. In a pilot test, a group of consultants was assessed using the final collection of statements of the MFAT. They received a report with their personal results and subsequently evaluated the assessment method. In total, 66 statements were developed and after validation they were reduced and reformulated to 35. Mean scores for relevance and "easy to understand" of the statements were in the range between "very high degree" and "high degree". In the pilot test, 18 consultants were assessed by themselves, by 141 other physicians and by 125 other professionals in the hospital. About two thirds greatly benefited of the assessment report and half identified areas for personal development. About a third did not want the head of their department to know the assessment results directly; however, two thirds found a potential value in discussing the results with the head. We developed an MFAT for consultants with relevant and understandable statements. A pilot test confirmed that most of the consultants gained from the assessment, but some did not like to share their results with their heads. For these specialists other methods should be used.

  5. New clinical validation method for automated sphygmomanometer: a proposal by Japan ISO-WG for sphygmomanometer standard.

    Science.gov (United States)

    Shirasaki, Osamu; Asou, Yosuke; Takahashi, Yukio

    2007-12-01

    Owing to fast or stepwise cuff deflation, or measuring at places other than the upper arm, the clinical accuracy of most recent automated sphygmomanometers (auto-BPMs) cannot be validated by one-arm simultaneous comparison, which would be the only accurate validation method based on auscultation. Two main alternative methods are provided by current standards, that is, two-arm simultaneous comparison (method 1) and one-arm sequential comparison (method 2); however, the accuracy of these validation methods might not be sufficient to compensate for the suspicious accuracy in lateral blood pressure (BP) differences (LD) and/or BP variations (BPV) between the device and reference readings. Thus, the Japan ISO-WG for sphygmomanometer standards has been studying a new method that might improve validation accuracy (method 3). The purpose of this study is to determine the appropriateness of method 3 by comparing immunity to LD and BPV with those of the current validation methods (methods 1 and 2). The validation accuracy of the above three methods was assessed in human participants [N=120, 45+/-15.3 years (mean+/-SD)]. An oscillometric automated monitor, Omron HEM-762, was used as the tested device. When compared with the others, methods 1 and 3 showed a smaller intra-individual standard deviation of device error (SD1), suggesting their higher reproducibility of validation. The SD1 by method 2 (P=0.004) significantly correlated with the participant's BP, supporting our hypothesis that the increased SD of device error by method 2 is at least partially caused by essential BPV. Method 3 showed a significantly (P=0.0044) smaller interparticipant SD of device error (SD2), suggesting its higher interparticipant consistency of validation. Among the methods of validation of the clinical accuracy of auto-BPMs, method 3, which showed the highest reproducibility and highest interparticipant consistency, can be proposed as being the most appropriate.

  6. Determination of vitamin C in foods: current state of method validation.

    Science.gov (United States)

    Spínola, Vítor; Llorent-Martínez, Eulogio J; Castilho, Paula C

    2014-11-21

    Vitamin C is one of the most important vitamins, so reliable information about its content in foodstuffs is a concern to both consumers and quality control agencies. However, the heterogeneity of food matrixes and the potential degradation of this vitamin during its analysis create enormous challenges. This review addresses the development and validation of high-performance liquid chromatography methods for vitamin C analysis in food commodities, during the period 2000-2014. The main characteristics of vitamin C are mentioned, along with the strategies adopted by most authors during sample preparation (freezing and acidification) to avoid vitamin oxidation. After that, the advantages and handicaps of different analytical methods are discussed. Finally, the main aspects concerning method validation for vitamin C analysis are critically discussed. Parameters such as selectivity, linearity, limit of quantification, and accuracy were studied by most authors. Recovery experiments during accuracy evaluation were in general satisfactory, with usual values between 81 and 109%. However, few methods considered vitamin C stability during the analytical process, and the study of the precision was not always clear or complete. Potential future improvements regarding proper method validation are indicated to conclude this review. Copyright © 2014. Published by Elsevier B.V.

  7. 42 CFR 478.15 - QIO review of changes resulting from DRG validation.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false QIO review of changes resulting from DRG validation... review of changes resulting from DRG validation. (a) General rules. (1) A provider or practitioner dissatisfied with a change to the diagnostic or procedural coding information made by a QIO as a result of DRG...

  8. Evaluation of the confusion matrix method in the validation of an automated system for measuring feeding behaviour of cattle.

    Science.gov (United States)

    Ruuska, Salla; Hämäläinen, Wilhelmiina; Kajava, Sari; Mughal, Mikaela; Matilainen, Pekka; Mononen, Jaakko

    2018-03-01

    The aim of the present study was to evaluate empirically confusion matrices in device validation. We compared the confusion matrix method to linear regression and error indices in the validation of a device measuring feeding behaviour of dairy cattle. In addition, we studied how to extract additional information on classification errors with confusion probabilities. The data consisted of 12 h behaviour measurements from five dairy cows; feeding and other behaviour were detected simultaneously with a device and from video recordings. The resulting 216 000 pairs of classifications were used to construct confusion matrices and calculate performance measures. In addition, hourly durations of each behaviour were calculated and the accuracy of measurements was evaluated with linear regression and error indices. All three validation methods agreed when the behaviour was detected very accurately or inaccurately. Otherwise, in the intermediate cases, the confusion matrix method and error indices produced relatively concordant results, but the linear regression method often disagreed with them. Our study supports the use of confusion matrix analysis in validation since it is robust to any data distribution and type of relationship, it makes a stringent evaluation of validity, and it offers extra information on the type and sources of errors. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. CONSTRUCT VALIDITY AND SCORING METHODS OF THE WORLD HEALTH ORGANIZATION- HEALTH AND WORK PERFORMANCE QUESTIONNAIRE AMONG WORKERS WITH ARTHRITIS AND RHEUMATOLOGICAL CONDITIONS

    Science.gov (United States)

    AlHeresh, Rawan; LaValley, Michael P.; Coster, Wendy; Keysor, Julie J.

    2017-01-01

    Objective To evaluate construct validity and scoring methods of the world health organization- health and work performance questionnaire (HPQ) for people with arthritis. Methods Construct validity was examined through hypothesis testing using the recommended guidelines of the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN). Results The HPQ using the absolute scoring method showed moderate construct validity as 4 of the 7 hypotheses were met. The HPQ using the relative scoring method had weak construct validity as only one of the 7 hypotheses were met. Conclusion The absolute scoring method for the HPQ is superior in construct validity to the relative scoring method in assessing work performance among people with arthritis and related rheumatic conditions; however, more research is needed to further explore other psychometric properties of the HPQ. PMID:28598938

  10. Comparison of validation methods for forming simulations

    Science.gov (United States)

    Schug, Alexander; Kapphan, Gabriel; Bardl, Georg; Hinterhölzl, Roland; Drechsler, Klaus

    2018-05-01

    The forming simulation of fibre reinforced thermoplastics could reduce the development time and improve the forming results. But to take advantage of the full potential of the simulations it has to be ensured that the predictions for material behaviour are correct. For that reason, a thorough validation of the material model has to be conducted after characterising the material. Relevant aspects for the validation of the simulation are for example the outer contour, the occurrence of defects and the fibre paths. To measure these features various methods are available. Most relevant and also most difficult to measure are the emerging fibre orientations. For that reason, the focus of this study was on measuring this feature. The aim was to give an overview of the properties of different measuring systems and select the most promising systems for a comparison survey. Selected were an optical, an eddy current and a computer-assisted tomography system with the focus on measuring the fibre orientations. Different formed 3D parts made of unidirectional glass fibre and carbon fibre reinforced thermoplastics were measured. Advantages and disadvantages of the tested systems were revealed. Optical measurement systems are easy to use, but are limited to the surface plies. With an eddy current system also lower plies can be measured, but it is only suitable for carbon fibres. Using a computer-assisted tomography system all plies can be measured, but the system is limited to small parts and challenging to evaluate.

  11. A Method for Ship Collision Damage and Energy Absorption Analysis and its Validation

    DEFF Research Database (Denmark)

    Zhang, Shengming; Pedersen, Preben Terndrup

    2016-01-01

    -examine this method’s validity andaccuracy for ship collision damage analysis in shipdesign assessments by comprehensive validations withthe experimental results from the public domain. Twentyexperimental tests have been selected, analysed andcompared with the results calculated using the proposedmethod. It can......For design evaluation there is a need for a method whichis fast, practical and yet accurate enough to determine theabsorbed energy and collision damage extent in shipcollision analysis. The most well-known simplifiedempirical approach to collision analysis was madeprobably by Minorsky and its...... limitation is also wellrecognized.The authors have previously developedsimple expressions for the relation between the absorbedenergy and the damaged material volume which take intoaccount the structural arrangements, the materialproperties and the damage modes. The purpose of thepresent paper is to re...

  12. [Data validation methods and discussion on Chinese materia medica resource survey].

    Science.gov (United States)

    Zhang, Yue; Ma, Wei-Feng; Zhang, Xiao-Bo; Zhu, Shou-Dong; Guo, Lan-Ping; Wang, Xing-Xing

    2013-07-01

    From the beginning of the fourth national survey of the Chinese materia medica resources, there were 22 provinces have conducted pilots. The survey teams have reported immense data, it put forward the very high request to the database system construction. In order to ensure the quality, it is necessary to check and validate the data in database system. Data validation is important methods to ensure the validity, integrity and accuracy of census data. This paper comprehensively introduce the data validation system of the fourth national survey of the Chinese materia medica resources database system, and further improve the design idea and programs of data validation. The purpose of this study is to promote the survey work smoothly.

  13. Validation of cleaning method for various parts fabricated at a Beryllium facility

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Cynthia M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-12-15

    This study evaluated and documented a cleaning process that is used to clean parts that are fabricated at a beryllium facility at Los Alamos National Laboratory. The purpose of evaluating this cleaning process was to validate and approve it for future use to assure beryllium surface levels are below the Department of Energy’s release limits without the need to sample all parts leaving the facility. Inhaling or coming in contact with beryllium can cause an immune response that can result in an individual becoming sensitized to beryllium, which can then lead to a disease of the lungs called chronic beryllium disease, and possibly lung cancer. Thirty aluminum and thirty stainless steel parts were fabricated on a lathe in the beryllium facility, as well as thirty-two beryllium parts, for the purpose of testing a parts cleaning method that involved the use of ultrasonic cleaners. A cleaning method was created, documented, validated, and approved, to reduce beryllium contamination.

  14. Validated spectrophotometric methods for simultaneous determination of troxerutin and carbazochrome in dosage form

    Science.gov (United States)

    Khattab, Fatma I.; Ramadan, Nesrin K.; Hegazy, Maha A.; Al-Ghobashy, Medhat A.; Ghoniem, Nermine S.

    2015-03-01

    Four simple, accurate, sensitive and precise spectrophotometric methods were developed and validated for simultaneous determination of Troxerutin (TXN) and Carbazochrome (CZM) in their bulk powders, laboratory prepared mixtures and pharmaceutical dosage forms. Method A is first derivative spectrophotometry (D1) where TXN and CZM were determined at 294 and 483.5 nm, respectively. Method B is first derivative of ratio spectra (DD1) where the peak amplitude at 248 for TXN and 439 nm for CZM were used for their determination. Method C is ratio subtraction (RS); in which TXN was determined at its λmax (352 nm) in the presence of CZM which was determined by D1 at 483.5 nm. While, method D is mean centering of the ratio spectra (MCR) in which the mean centered values at 300 nm and 340.0 nm were used for the two drugs in a respective order. The two compounds were simultaneously determined in the concentration ranges of 5.00-50.00 μg mL-1 and 0.5-10.0 μg mL-1 for TXN and CZM, respectively. The methods were validated according to the ICH guidelines and the results were statistically compared to the manufacturer's method.

  15. Method validation for simultaneous counting of Total α , β in Drinking Water using Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.

    2014-05-01

    In this work, Method Validation Methods and Pulse Shape Analysis were validated to determine gross Alpha and Beta Emitters in Drinking Water using Liquid Scintillation Counter Win spectral 1414. Validation parameters include Method Detection Limit, Method Quantitation Limit, Repeatability Limit, Intermediate Precision, Trueness) Bias), Recovery Coefficient, Linearity and Uncertainty Budget in analysis. The results show that the Method Detection Limit and Method Quantitation Limit were 0.07, 0.24 Bq/l for Alpha emitters respectively, and 0.42, 1.4 Bq/l for Beta emitters, respectively. The relative standard deviation of Repeatability Limit reached 2.81% for Alpha emitters and 3.96% for Beta emitters. In addition to, the relative standard deviation of Intermediate Precisionis was 0.54% for Alpha emitters and 1.17% for Beta emitters. Moreover, the trueness was - 7.7% for Alpha emitters and - 4.5% for Beta emitters. Recovery Coefficient ranged between 87 - 96% and 88-101 for Alpha and Beta emitters, respectively. Linearity reached 1 for both Alpha and Beta emitters. on the other hand, Uncertainty Budget for all continents was 96.65% ,83.14% for Alpha and Beta emitters, respectively (author).

  16. Estimating Rooftop Suitability for PV: A Review of Methods, Patents, and Validation Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Melius, J. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Margolis, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ong, S. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-12-01

    A number of methods have been developed using remote sensing data to estimate rooftop area suitable for the installation of photovoltaics (PV) at various geospatial resolutions. This report reviews the literature and patents on methods for estimating rooftop-area appropriate for PV, including constant-value methods, manual selection methods, and GIS-based methods. This report also presents NREL's proposed method for estimating suitable rooftop area for PV using Light Detection and Ranging (LiDAR) data in conjunction with a GIS model to predict areas with appropriate slope, orientation, and sunlight. NREL's method is validated against solar installation data from New Jersey, Colorado, and California to compare modeled results to actual on-the-ground measurements.

  17. Noninvasive assessment of mitral inertness [correction of inertance]: clinical results with numerical model validation.

    Science.gov (United States)

    Firstenberg, M S; Greenberg, N L; Smedira, N G; McCarthy, P M; Garcia, M J; Thomas, J D

    2001-01-01

    Inertial forces (Mdv/dt) are a significant component of transmitral flow, but cannot be measured with Doppler echo. We validated a method of estimating Mdv/dt. Ten patients had a dual sensor transmitral (TM) catheter placed during cardiac surgery. Doppler and 2D echo was performed while acquiring LA and LV pressures. Mdv/dt was determined from the Bernoulli equation using Doppler velocities and TM gradients. Results were compared with numerical modeling. TM gradients (range: 1.04-14.24 mmHg) consisted of 74.0 +/- 11.0% inertial forcers (range: 0.6-12.9 mmHg). Multivariate analysis predicted Mdv/dt = -4.171(S/D (RATIO)) + 0.063(LAvolume-max) + 5. Using this equation, a strong relationship was obtained for the clinical dataset (y=0.98x - 0.045, r=0.90) and the results of numerical modeling (y=0.96x - 0.16, r=0.84). TM gradients are mainly inertial and, as validated by modeling, can be estimated with echocardiography.

  18. Developmental validation of a Nextera XT mitogenome Illumina MiSeq sequencing method for high-quality samples.

    Science.gov (United States)

    Peck, Michelle A; Sturk-Andreaggi, Kimberly; Thomas, Jacqueline T; Oliver, Robert S; Barritt-Ross, Suzanne; Marshall, Charla

    2018-05-01

    Generating mitochondrial genome (mitogenome) data from reference samples in a rapid and efficient manner is critical to harnessing the greater power of discrimination of the entire mitochondrial DNA (mtDNA) marker. The method of long-range target enrichment, Nextera XT library preparation, and Illumina sequencing on the MiSeq is a well-established technique for generating mitogenome data from high-quality samples. To this end, a validation was conducted for this mitogenome method processing up to 24 samples simultaneously along with analysis in the CLC Genomics Workbench and utilizing the AQME (AFDIL-QIAGEN mtDNA Expert) tool to generate forensic profiles. This validation followed the Federal Bureau of Investigation's Quality Assurance Standards (QAS) for forensic DNA testing laboratories and the Scientific Working Group on DNA Analysis Methods (SWGDAM) validation guidelines. The evaluation of control DNA, non-probative samples, blank controls, mixtures, and nonhuman samples demonstrated the validity of this method. Specifically, the sensitivity was established at ≥25 pg of nuclear DNA input for accurate mitogenome profile generation. Unreproducible low-level variants were observed in samples with low amplicon yields. Further, variant quality was shown to be a useful metric for identifying sequencing error and crosstalk. Success of this method was demonstrated with a variety of reference sample substrates and extract types. These studies further demonstrate the advantages of using NGS techniques by highlighting the quantitative nature of heteroplasmy detection. The results presented herein from more than 175 samples processed in ten sequencing runs, show this mitogenome sequencing method and analysis strategy to be valid for the generation of reference data. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Validation and uncertainty estimation of fast neutron activation analysis method for Cu, Fe, Al, Si elements in sediment samples

    International Nuclear Information System (INIS)

    Sunardi; Samin Prihatin

    2010-01-01

    Validation and uncertainty estimation of Fast Neutron Activation Analysis (FNAA) method for Cu, Fe, Al, Si elements in sediment samples has been conduced. The aim of the research is to confirm whether FNAA method is still matches to ISO/lEC 17025-2005 standard. The research covered the verification, performance, validation of FNM and uncertainty estimation. Standard of SRM 8704 and sediments were weighted for certain weight and irradiated with 14 MeV fast neutron and then counted using gamma spectrometry. The result of validation method for Cu, Fe, Al, Si element showed that the accuracy were in the range of 95.89-98.68 %, while the precision were in the range 1.13-2.29 %. The result of uncertainty estimation for Cu, Fe, Al, and Si were 2.67, 1.46, 1.71 and 1.20 % respectively. From this data, it can be concluded that the FNM method is still reliable and valid for element contents analysis in samples, because the accuracy is up to 95 % and the precision is under 5 %, while the uncertainty are relatively small and suitable for the range 95 % level of confidence where the uncertainty maximum is 5 %. (author)

  20. Specification and Preliminary Validation of IAT (Integrated Analysis Techniques) Methods: Executive Summary.

    Science.gov (United States)

    1985-03-01

    conceptual framwork , and preliminary validation of IAT concepts. Planned work for FY85, including more extensive validation, is also described. 20...Developments: Required Capabilities .... ......... 10 2-1 IAT Conceptual Framework - FY85 (FEO) ..... ........... 11 2-2 Recursive Nature of Decomposition...approach: 1) Identify needs & requirements for IAT. 2) Develop IAT conceptual framework. 3) Validate IAT methods. 4) Develop applications materials. To

  1. Testing and Validation of the Dynamic Inertia Measurement Method

    Science.gov (United States)

    Chin, Alexander W.; Herrera, Claudia Y.; Spivey, Natalie D.; Fladung, William A.; Cloutier, David

    2015-01-01

    The Dynamic Inertia Measurement (DIM) method uses a ground vibration test setup to determine the mass properties of an object using information from frequency response functions. Most conventional mass properties testing involves using spin tables or pendulum-based swing tests, which for large aerospace vehicles becomes increasingly difficult and time-consuming, and therefore expensive, to perform. The DIM method has been validated on small test articles but has not been successfully proven on large aerospace vehicles. In response, the National Aeronautics and Space Administration Armstrong Flight Research Center (Edwards, California) conducted mass properties testing on an "iron bird" test article that is comparable in mass and scale to a fighter-type aircraft. The simple two-I-beam design of the "iron bird" was selected to ensure accurate analytical mass properties. Traditional swing testing was also performed to compare the level of effort, amount of resources, and quality of data with the DIM method. The DIM test showed favorable results for the center of gravity and moments of inertia; however, the products of inertia showed disagreement with analytical predictions.

  2. Development and Statistical Validation of Spectrophotometric Methods for the Estimation of Nabumetone in Tablet Dosage Form

    Directory of Open Access Journals (Sweden)

    A. R. Rote

    2010-01-01

    Full Text Available Three new simple, economic spectrophotometric methods were developed and validated for the estimation of nabumetone in bulk and tablet dosage form. First method includes determination of nabumetone at absorption maxima 330 nm, second method applied was area under curve for analysis of nabumetone in the wavelength range of 326-334 nm and third method was First order derivative spectra with scaling factor 4. Beer law obeyed in the concentration range of 10-30 μg/mL for all three methods. The correlation coefficients were found to be 0.9997, 0.9998 and 0.9998 by absorption maxima, area under curve and first order derivative spectra. Results of analysis were validated statistically and by performing recovery studies. The mean percent recoveries were found satisfactory for all three methods. The developed methods were also compared statistically using one way ANOVA. The proposed methods have been successfully applied for the estimation of nabumetone in bulk and pharmaceutical tablet dosage form.

  3. Validity and reliability of a method for assessment of cervical vertebral maturation.

    Science.gov (United States)

    Zhao, Xiao-Guang; Lin, Jiuxiang; Jiang, Jiu-Hui; Wang, Qingzhu; Ng, Sut Hong

    2012-03-01

    To evaluate the validity and reliability of the cervical vertebral maturation (CVM) method with a longitudinal sample. Eighty-six cephalograms from 18 subjects (5 males and 13 females) were selected from the longitudinal database. Total mandibular length was measured on each film; an increased rate served as the gold standard in examination of the validity of the CVM method. Eleven orthodontists, after receiving intensive training in the CVM method, evaluated all films twice. Kendall's W and the weighted kappa statistic were employed. Kendall's W values were higher than 0.8 at both times, indicating strong interobserver reproducibility, but interobserver agreement was documented twice at less than 50%. A wide range of intraobserver agreement was noted (40.7%-79.1%), and substantial intraobserver reproducibility was proved by kappa values (0.53-0.86). With regard to validity, moderate agreement was reported between the gold standard and observer staging at the initial time (kappa values 0.44-0.61). However, agreement seemed to be unacceptable for clinical use, especially in cervical stage 3 (26.8%). Even though the validity and reliability of the CVM method proved statistically acceptable, we suggest that many other growth indicators should be taken into consideration in evaluating adolescent skeletal maturation.

  4. Update of Standard Practices for New Method Validation in Forensic Toxicology.

    Science.gov (United States)

    Wille, Sarah M R; Coucke, Wim; De Baere, Thierry; Peters, Frank T

    2017-01-01

    International agreement concerning validation guidelines is important to obtain quality forensic bioanalytical research and routine applications as it all starts with the reporting of reliable analytical data. Standards for fundamental validation parameters are provided in guidelines as those from the US Food and Drug Administration (FDA), the European Medicines Agency (EMA), the German speaking Gesellschaft fur Toxikologie und Forensische Chemie (GTFCH) and the Scientific Working Group of Forensic Toxicology (SWGTOX). These validation parameters include selectivity, matrix effects, method limits, calibration, accuracy and stability, as well as other parameters such as carryover, dilution integrity and incurred sample reanalysis. It is, however, not easy for laboratories to implement these guidelines into practice as these international guidelines remain nonbinding protocols, that depend on the applied analytical technique, and that need to be updated according the analyst's method requirements and the application type. In this manuscript, a review of the current guidelines and literature concerning bioanalytical validation parameters in a forensic context is given and discussed. In addition, suggestions for the experimental set-up, the pros and cons of statistical approaches and adequate acceptance criteria for the validation of bioanalytical applications are given. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  5. Modelling of the activity system - development of an evaluation method for integrated system validation

    International Nuclear Information System (INIS)

    Norros, Leena; Savioja, Paula

    2004-01-01

    In this paper we present our recent research which focuses on creating an evaluation method for human-system interfaces of complex systems. The method is aimed for use in the validation of modernised nuclear power plant (NPP) control rooms, and other complex systems with high reliability requirements. The task in validation is to determine whether the human-system functions safely and effectively. This question can be operationalized to the selection of relevant operational features and their appropriate acceptance criteria. Thus, there is a need to ensure that the results of the evaluation can be generalized so that they serve the purpose of integrated system validation. The definition of the appropriate acceptance criteria provides basis for the judgement of the appropriateness of the performance of the system. We propose that the operational situations and the acceptance criteria should be defined based on modelling of the NPP operation that is comprehended as an activity system. We developed a new core-tasks modelling framework. It is a formative modelling approach that combines causal, functional and understanding explanations of system performance. In this paper we reason how modelling can be used as a medium to determine the validity of the emerging control room system. (Author)

  6. Softcopy quality ruler method: implementation and validation

    Science.gov (United States)

    Jin, Elaine W.; Keelan, Brian W.; Chen, Junqing; Phillips, Jonathan B.; Chen, Ying

    2009-01-01

    A softcopy quality ruler method was implemented for the International Imaging Industry Association (I3A) Camera Phone Image Quality (CPIQ) Initiative. This work extends ISO 20462 Part 3 by virtue of creating reference digital images of known subjective image quality, complimenting the hardcopy Standard Reference Stimuli (SRS). The softcopy ruler method was developed using images from a Canon EOS 1Ds Mark II D-SLR digital still camera (DSC) and a Kodak P880 point-and-shoot DSC. Images were viewed on an Apple 30in Cinema Display at a viewing distance of 34 inches. Ruler images were made for 16 scenes. Thirty ruler images were generated for each scene, representing ISO 20462 Standard Quality Scale (SQS) values of approximately 2 to 31 at an increment of one just noticeable difference (JND) by adjusting the system modulation transfer function (MTF). A Matlab GUI was developed to display the ruler and test images side-by-side with a user-adjustable ruler level controlled by a slider. A validation study was performed at Kodak, Vista Point Technology, and Aptina Imaging in which all three companies set up a similar viewing lab to run the softcopy ruler method. The results show that the three sets of data are in reasonable agreement with each other, with the differences within the range expected from observer variability. Compared to previous implementations of the quality ruler, the slider-based user interface allows approximately 2x faster assessments with 21.6% better precision.

  7. Method validation and verification in liquid scintillation counting using the long-term uncertainty method (LTUM) on two decades of proficiency test data

    International Nuclear Information System (INIS)

    Verrezen, F.; Vasile, M.; Loots, H.; Bruggeman, M.

    2017-01-01

    Results from proficiency tests gathered over the past two decades by the laboratory for low level radioactivity measurements for liquid scintillation counting of 3 H (184 results) and 14 C (74 results) are used to verify the validated measurement methods used by the laboratory, in particular the estimated uncertainty budget of the method and its reproducibility and stability. A linear regression approach is used for the analysis of the results, described in the literature as the long term uncertainty in measurement method. The present study clearly indicates the advantages of using proficiency test results in identifying possible constant or proportional bias effects as well as the possibility to compare the laboratory performance with the performance of peer laboratories. (author)

  8. Development and validation of a thin-layer chromatography method for stability studies of naproxen

    International Nuclear Information System (INIS)

    Rodriguez Hernandez, Yaslenis; Suarez Perez, Yania; Garcia Pulpeiro, Oscar; Rodriguez Borges, Tania

    2011-01-01

    The validation of an analytical method was carried out to be applied to the stability studies of the future formulations of naproxen suppositories for infant and adult use. The factors which mostly influenced in the naproxen stability were determined, the major degradation occurred in oxidizing acid medium and by action of light. The possible formation of esters between the free carboxyl group present in naproxen and the glyceryl monoestereate present in the base was identified as one of the degradation paths in the new formulation. The results were satisfactory. A thin-layer chromatography-based method was developed as well as the best chromatographic conditions were selected. GF 254 silica gel plates and ultraviolet developer at 254 nm were employed. Three solvent systems were evaluated of which A made up of glacial acetic: tetrahydrofurane:toluene (3:9:90 v/v/v)allowed adequate resolution between the analyte and the possible degradation products, with detection limit of 1 μg. The use of the suggested method was restricted to the identification of possible degradation products just for qualitative purposes and not as final test. The method proved to be sensitive and selective enough to be applied for the stated objective, according to the validation results

  9. Triangulation, Respondent Validation, and Democratic Participation in Mixed Methods Research

    Science.gov (United States)

    Torrance, Harry

    2012-01-01

    Over the past 10 years or so the "Field" of "Mixed Methods Research" (MMR) has increasingly been exerting itself as something separate, novel, and significant, with some advocates claiming paradigmatic status. Triangulation is an important component of mixed methods designs. Triangulation has its origins in attempts to validate research findings…

  10. Validity of a Manual Soft Tissue Profile Prediction Method Following Mandibular Setback Osteotomy

    OpenAIRE

    Kolokitha, Olga-Elpis

    2007-01-01

    Objectives The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. Methods To test the validity of the manu...

  11. The Validity of Dimensional Regularization Method on Fractal Spacetime

    Directory of Open Access Journals (Sweden)

    Yong Tao

    2013-01-01

    Full Text Available Svozil developed a regularization method for quantum field theory on fractal spacetime (1987. Such a method can be applied to the low-order perturbative renormalization of quantum electrodynamics but will depend on a conjectural integral formula on non-integer-dimensional topological spaces. The main purpose of this paper is to construct a fractal measure so as to guarantee the validity of the conjectural integral formula.

  12. Stability indicating method development and validation of assay method for the estimation of rizatriptan benzoate in tablet

    Directory of Open Access Journals (Sweden)

    Chandrashekhar K. Gadewar

    2017-05-01

    Full Text Available A simple, sensitive, precise and specific high performance liquid chromatography method was developed and validated for the determination of rizatriptan in rizatriptan benzoate tablet. The separation was carried out by using a mobile phase consisting of acetonitrile: pH 3.4 phosphate buffer in ratio of 20:80. The column used was Zorbax SB CN 250 mm × 4.6 mm, 5 μ with a flow rate of 1 ml/min using UV detection at 225 nm. The retention time of rizatriptan and benzoic acid was found to be 4.751 and 8.348 min respectively. A forced degradation study of rizatriptan benzoate in its tablet form was conducted under the condition of hydrolysis, oxidation, thermal and photolysis. Rizatriptan was found to be stable in basic buffer while in acidic buffer was found to be degraded (water bath at 60 °C for 15 min. The detector response of rizatriptan is directly proportional to concentration ranging from 30% to 160% of test concentration i.e. 15.032 to 80.172 mcg/ml. Results of analysis were validated statistically and by recovery studies (mean recovery = 99.44. The result of the study showed that the proposed method is simple, rapid, precise and accurate, which is useful for the routine determination of rizatriptan in pharmaceutical dosage forms.

  13. Validation of analytical methods for the quality control of Naproxen suppositories

    International Nuclear Information System (INIS)

    Rodriguez Hernandez, Yaslenis; Suarez Perez, Yania; Garcia Pulpeiro, Oscar; Hernandez Contreras, Orestes Yuniel

    2011-01-01

    The analysis methods that will be used for the quality control of the future Cuban-made Naproxen suppositories for adults and children were developed for the first time in this paper. One method based on direct ultraviolet spectrophotometry was put forward, which proved to be specific, linear, accurate and precise for the quality control of Naproxen suppositories, taking into account the presence of chromophore groups in their structure. Likewise, the direct semi-aqueous acid-base volumetry method aimed at the quality control of the Naproxen raw material was changed and adapted to the quality control of suppositories. On the basis of the validation process, there was demonstrated the adequate specificity of this method with respect to the formulation components, as well as its linearity, accuracy and precision in 1-3 mg/ml range. The final results were compared and no significant statistical differences among the replicas per each dose were found in both methods; therefore, both may be used in the quality control of Naproxen suppositories

  14. Validation and results of a questionnaire for functional bowel disease in out-patients

    Directory of Open Access Journals (Sweden)

    Skordilis Panagiotis

    2002-05-01

    Full Text Available Abstract Background The aim was to evaluate and validate a bowel disease questionnaire in patients attending an out-patient gastroenterology clinic in Greece. Methods This was a prospective study. Diagnosis was based on detailed clinical and laboratory evaluation. The questionnaire was tested on a pilot group of patients. Interviewer-administration technique was used. One-hundred-and-forty consecutive patients attending the out-patient clinic for the first time and fifty healthy controls selected randomly participated in the study. Reliability (kappa statistics and validity of the questionnaire were tested. We used logistic regression models and binary recursive partitioning for assessing distinguishing ability among irritable bowel syndrome (IBS, functional dyspepsia and organic disease patients. Results Mean time for questionnaire completion was 18 min. In test-retest procedure a good agreement was obtained (kappa statistics 0.82. There were 55 patients diagnosed as having IBS, 18 with functional dyspepsia (Rome I criteria, 38 with organic disease. Location of pain was a significant distinguishing factor, patients with functional dyspepsia having no lower abdominal pain (p Conclusions This questionnaire for functional bowel disease is a valid and reliable instrument that can distinguish satisfactorily between organic and functional disease in an out-patient setting.

  15. Validity of proposed DSM-5 diagnostic criteria for nicotine use disorder: results from 734 Israeli lifetime smokers

    Science.gov (United States)

    Shmulewitz, D.; Wall, M.M.; Aharonovich, E.; Spivak, B.; Weizman, A.; Frisch, A.; Grant, B. F.; Hasin, D.

    2013-01-01

    Background The fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) proposes aligning nicotine use disorder (NUD) criteria with those for other substances, by including the current DSM fourth edition (DSM-IV) nicotine dependence (ND) criteria, three abuse criteria (neglect roles, hazardous use, interpersonal problems) and craving. Although NUD criteria indicate one latent trait, evidence is lacking on: (1) validity of each criterion; (2) validity of the criteria as a set; (3) comparative validity between DSM-5 NUD and DSM-IV ND criterion sets; and (4) NUD prevalence. Method Nicotine criteria (DSM-IV ND, abuse and craving) and external validators (e.g. smoking soon after awakening, number of cigarettes per day) were assessed with a structured interview in 734 lifetime smokers from an Israeli household sample. Regression analysis evaluated the association between validators and each criterion. Receiver operating characteristic analysis assessed the association of the validators with the DSM-5 NUD set (number of criteria endorsed) and tested whether DSM-5 or DSM-IV provided the most discriminating criterion set. Changes in prevalence were examined. Results Each DSM-5 NUD criterion was significantly associated with the validators, with strength of associations similar across the criteria. As a set, DSM-5 criteria were significantly associated with the validators, were significantly more discriminating than DSM-IV ND criteria, and led to increased prevalence of binary NUD (two or more criteria) over ND. Conclusions All findings address previous concerns about the DSM-IV nicotine diagnosis and its criteria and support the proposed changes for DSM-5 NUD, which should result in improved diagnosis of nicotine disorders. PMID:23312475

  16. Validation of methods for determination of free water content in poultry meat

    Directory of Open Access Journals (Sweden)

    Jarmila Žítková

    2007-01-01

    Full Text Available Methods for determination of free water content in poultry meat are described in Commission Regulation EEC No 1538/91 as amended and in ČSN 57 3100. Two of them (method A and D have been validated in conditions of a Czech poultry processing plant. The capacity of slaughtering was 6000 pieces per hour and carcasses were chilled by air with spraying. All determinations were carried out in the plant’s lab and in the lab of the Institute of Food Technology. Method A was used to detect the amount of water lost from frozen chicken during thawing in controlled conditions. Twenty carcasses from six weight groups (900 g–1400 g were tested. The average values of thaw loss water contents ranged between 0.46% and 1.71%, the average value of total 120 samples was 1.16%. The results were compared with the required maximum limit value of 3.3%. The water loss content was in negative correlation with the weight of chicken (r = –0.56. Method D (chemical test has been applied to determine the total water content of certain poultry cuts. It involved the determination of water and protein contents of 62 representative samples in total. The average values of ratio of water weight to proteins weight WA/RPA were in breast fillets 3.29, in legs with a portion of the back 4.06, legs 4.00, thighs 3.85 and drumsticks 4.10. The results corresponded to the required limit values for breast fillets 3.40 and for leg cuts 4.15. The ratio of water weight to proteins weight WA/RPA was correlated with the weight of chicken for breast fillets negatively (r = –0.61 and for leg cuts positively (r = 0.70. Different correlations can be explained by the distribution of water, protein and fat in carcasses. The evaluation of methods in the parameter of percentage ratio of the average value to the limit showed that method D (results were at the level of 97% of the limit was more exact than method A (results were at the level 32% of the limit but it is more expensive. Both methods

  17. Validation of internal dosimetry protocols based on stochastic method

    International Nuclear Information System (INIS)

    Mendes, Bruno M.; Fonseca, Telma C.F.; Almeida, Iassudara G.; Trindade, Bruno M.; Campos, Tarcisio P.R.

    2015-01-01

    Computational phantoms adapted to Monte Carlo codes have been applied successfully in radiation dosimetry fields. NRI research group has been developing Internal Dosimetry Protocols - IDPs, addressing distinct methodologies, software and computational human-simulators, to perform internal dosimetry, especially for new radiopharmaceuticals. Validation of the IDPs is critical to ensure the reliability of the simulations results. Inter comparisons of data from literature with those produced by our IDPs is a suitable method for validation. The aim of this study was to validate the IDPs following such inter comparison procedure. The Golem phantom has been reconfigured to run on MCNP5. The specific absorbed fractions (SAF) for photon at 30, 100 and 1000 keV energies were simulated based on the IDPs and compared with reference values (RV) published by Zankl and Petoussi-Henss, 1998. The SAF average differences from RV and those obtained in IDP simulations was 2.3 %. The SAF largest differences were found in situations involving low energy photons at 30 keV. The Adrenals and thyroid, i.e. the lowest mass organs, had the highest SAF discrepancies towards RV as 7.2 % and 3.8 %, respectively. The statistic differences of SAF applying our IDPs from reference values were considered acceptable at the 30, 100 and 1000 keV spectra. We believe that the main reason for the discrepancies in IDPs run, found in lower masses organs, was due to our source definition methodology. Improvements of source spatial distribution in the voxels may provide outputs more consistent with reference values for lower masses organs. (author)

  18. Validation of internal dosimetry protocols based on stochastic method

    Energy Technology Data Exchange (ETDEWEB)

    Mendes, Bruno M.; Fonseca, Telma C.F., E-mail: bmm@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Almeida, Iassudara G.; Trindade, Bruno M.; Campos, Tarcisio P.R., E-mail: tprcampos@yahoo.com.br [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2015-07-01

    Computational phantoms adapted to Monte Carlo codes have been applied successfully in radiation dosimetry fields. NRI research group has been developing Internal Dosimetry Protocols - IDPs, addressing distinct methodologies, software and computational human-simulators, to perform internal dosimetry, especially for new radiopharmaceuticals. Validation of the IDPs is critical to ensure the reliability of the simulations results. Inter comparisons of data from literature with those produced by our IDPs is a suitable method for validation. The aim of this study was to validate the IDPs following such inter comparison procedure. The Golem phantom has been reconfigured to run on MCNP5. The specific absorbed fractions (SAF) for photon at 30, 100 and 1000 keV energies were simulated based on the IDPs and compared with reference values (RV) published by Zankl and Petoussi-Henss, 1998. The SAF average differences from RV and those obtained in IDP simulations was 2.3 %. The SAF largest differences were found in situations involving low energy photons at 30 keV. The Adrenals and thyroid, i.e. the lowest mass organs, had the highest SAF discrepancies towards RV as 7.2 % and 3.8 %, respectively. The statistic differences of SAF applying our IDPs from reference values were considered acceptable at the 30, 100 and 1000 keV spectra. We believe that the main reason for the discrepancies in IDPs run, found in lower masses organs, was due to our source definition methodology. Improvements of source spatial distribution in the voxels may provide outputs more consistent with reference values for lower masses organs. (author)

  19. Validated Spectrophotometric Methods for Simultaneous Determination of Food Colorants and Sweeteners

    Directory of Open Access Journals (Sweden)

    Fatma Turak

    2013-01-01

    Full Text Available Two simple spectrophotometric methods have been proposed for simultaneous determination of two colorants (Indigotin and Brilliant Blue and two sweeteners (Acesulfame-K and Aspartame in synthetic mixtures and chewing gums without any prior separation or purification. The first method, derivative spectrophotometry (ZCDS, is based on recording the first derivative curves (for Indigotin, Brillant Blue, and Acesulfame-K and third-derivative curve (for Aspartame and determining each component using the zero-crossing technique. The other method, ratio derivative spectrophotometry (RDS, depends on application ratio spectra of first- and third-derivative spectrophotometry to resolve the interference due to spectral overlapping. Both colorants and sweeteners showed good linearity, with regression coefficients of 0.9992–0.9999. The LOD and LOQ values ranged from 0.05 to 0.33 μgmL−1 and from 0.06 to 0.47 μgmL−1, respectively. The intraday and interday precision tests produced good RSD% values (<0.81%; recoveries ranged from 99.78% to 100.67% for all two methods. The accuracy and precision of the methods have been determined, and the methods have been validated by analyzing synthetic mixtures containing colorants and sweeteners. Two methods were applied for the above combination, and satisfactory results were obtained. The results obtained by applying the ZCDS method were statistically compared with those obtained by the RDS method.

  20. A Method for Ship Collision Damage and Energy Absorption Analysis and its Validation

    DEFF Research Database (Denmark)

    Zhang, Shengming; Pedersen, Preben Terndrup

    2017-01-01

    For design evaluation, there is a need for a method which is fast, practical and yet accurate enough to deter-mine the absorbed energy and collision damage extent in ship collision analysis. The most well-known sim-plified empirical approach to collision analysis was made probably by Minorsky......, and its limitation is alsowell-recognised. The authors have previously developed simple expressions for the relation between theabsorbed energy and the damaged material volume which take into account the structural arrangements,the material properties and the damage modes. The purpose of the present paper...... is to re-examine thismethod’s validity and accuracy for ship collision damage analysis in ship design assessments by compre-hensive validations with experimental results from the public domain. In total, 20 experimental tests havebeen selected, analysed and compared with the results calculated using...

  1. Experimental validation of the intrinsic spatial efficiency method over a wide range of sizes for cylindrical sources

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz-Ramŕez, Pablo, E-mail: rapeitor@ug.uchile.cl; Larroquette, Philippe [Departamento de Física, Facultad de Ciencias, Universidad de Chile (Chile); Camilla, S. [Departamento de Física, Universidad Tecnológica Metropolitana (Chile)

    2016-07-07

    The intrinsic spatial efficiency method is a new absolute method to determine the efficiency of a gamma spectroscopy system for any extended source. In the original work the method was experimentally demonstrated and validated for homogeneous cylindrical sources containing {sup 137}Cs, whose sizes varied over a small range (29.5 mm radius and 15.0 to 25.9 mm height). In this work we present an extension of the validation over a wide range of sizes. The dimensions of the cylindrical sources vary between 10 to 40 mm height and 8 to 30 mm radius. The cylindrical sources were prepared using the reference material IAEA-372, which had a specific activity of 11320 Bq/kg at july 2006. The obtained results were better for the sources with 29 mm radius showing relative bias lesser than 5% and for the sources with 10 mm height showing relative bias lesser than 6%. In comparison with the obtained results in the work where we present the method, the majority of these results show an excellent agreement.

  2. Gradient HPLC method development and validation for Simultaneous estimation of Rosiglitazone and Gliclazide.

    Directory of Open Access Journals (Sweden)

    Uttam Singh Baghel

    2012-10-01

    Full Text Available Objective: The aim of present work was to develop a gradient RP-HPLC method for simultaneous analysis of rosiglitazone and gliclazide, in a tablet dosage form. Method: Chromatographic system was optimized using a hypersil C18 (250mm x 4.6mm, 5毺 m column with potassium dihydrogen phosphate (pH-7.0 and acetonitrile in the ratio of 60:40, as mobile phase, at a flow rate of 1.0 ml/min. Detection was carried out at 225 nm by a SPD-20A prominence UV/Vis detector. Result: Rosiglitazone and gliclazide were eluted with retention times of 17.36 and 7.06 min, respectively. Beer’s Lambert ’s Law was obeyed over the concentration ranges of 5 to 70 毺 g/ml and 2 to 12 毺 g/ml for rosiglitazone and gliclazide, respectively. Conclusion: The high recovery and low coefficients of variation confirm the suitability of the method for simultaneous analysis of both drugs in a tablets dosage form. Statistical analysis proves that the method is sensitive and significant for the analysis of rosiglitazone and gliclazide in pure and in pharmaceutical dosage form without any interference from the excipients. The method was validated in accordance with ICH guidelines. Validation revealed the method is specific, rapid, accurate, precise, reliable, and reproducible.

  3. Development and Validation of a RP-HPLC Method for the ...

    African Journals Online (AJOL)

    Development and Validation of a RP-HPLC Method for the Simultaneous Determination of Rifampicin and a Flavonoid Glycoside - A Novel ... range, accuracy, precision, limit of detection, limit of quantification, robustness and specificity.

  4. Using digital photography in a clinical setting: a valid, accurate, and applicable method to assess food intake.

    Science.gov (United States)

    Winzer, Eva; Luger, Maria; Schindler, Karin

    2018-06-01

    Regular monitoring of food intake is hardly integrated in clinical routine. Therefore, the aim was to examine the validity, accuracy, and applicability of an appropriate and also quick and easy-to-use tool for recording food intake in a clinical setting. Two digital photography methods, the postMeal method with a picture after the meal, the pre-postMeal method with a picture before and after the meal, and the visual estimation method (plate diagram; PD) were compared against the reference method (weighed food records; WFR). A total of 420 dishes from lunch (7 weeks) were estimated with both photography methods and the visual method. Validity, applicability, accuracy, and precision of the estimation methods, and additionally food waste, macronutrient composition, and energy content were examined. Tests of validity revealed stronger correlations for photography methods (postMeal: r = 0.971, p < 0.001; pre-postMeal: r = 0.995, p < 0.001) compared to the visual estimation method (r = 0.810; p < 0.001). The pre-postMeal method showed smaller variability (bias < 1 g) and also smaller overestimation and underestimation. This method accurately and precisely estimated portion sizes in all food items. Furthermore, the total food waste was 22% for lunch over the study period. The highest food waste was observed in salads and the lowest in desserts. The pre-postMeal digital photography method is valid, accurate, and applicable in monitoring food intake in clinical setting, which enables a quantitative and qualitative dietary assessment. Thus, nutritional care might be initiated earlier. This method might be also advantageous for quantitative and qualitative evaluation of food waste, with a resultantly reduction in costs.

  5. Validation and further development of a novel thermal analysis method

    Energy Technology Data Exchange (ETDEWEB)

    Mathews, E.H.; Shuttleworth, A.G.; Rousseau, P.G. [Pretoria Univ. (South Africa). Dept. of Mechanical Engineering

    1994-12-31

    The design of thermal and energy efficient buildings requires inter alia the investigation of the passive performance, natural ventilation, mechanical ventilation as well as structural and evaporative cooling of the building. Only when these fail to achieve the desired thermal comfort should mechanical cooling systems be considered. Few computer programs have the ability to investigate all these comfort regulating methods at the design stage. The QUICK design program can simulate these options with the exception of mechanical cooling. In this paper, Quick`s applicability is extended to include the analysis of basic air-conditioning systems. Since the design of these systems is based on indoor loads, it was necessary to validate QUICK`s load predictions before extending it. This article addresses validation in general and proposes a procedure to establish the efficiency of a program`s load predictions. This proposed procedure is used to compare load predictions by the ASHRAE, CIBSE, CARRIER, CHEETAH, BSIMAC and QUICK methods for 46 case studies involving 36 buildings in various climatic conditions. Although significant differences in the results of the various methods were observed, it is concluded that QUICK can be used with the same confidence as the other methods. It was further shown that load prediction programs usually under-estimate the effect of building mass and therefore over-estimate the peak loads. The details for the 46 case studies are available to other researchers for further verification purposes. With the confidence gained in its load predictions, QUICK was extended to include air-conditioning system analysis. The program was then applied to different case studies. It is shown that system size and energy usage can be reduced by more than 60% by using a combination of passive and mechanical cooling systems as well as different control strategies. (author)

  6. The Numerical Welding Simulation - Developments and Validation of Simplified and Bead Lumping Methods

    International Nuclear Information System (INIS)

    Baup, Olivier

    2001-01-01

    The aim of this work was to study the TIG multipass welding process on stainless steel, by means of numerical methods and then to work out simplified and bead lumping methods in order to reduce adjusting and realisation times of these calculations. A simulation was used as reference for the validation of these methods; after the presentation of the test series having led to the option choices of this calculation (2D generalised plane strains, elastoplastic model with an isotropic hardening, hardening restoration due to high temperatures), various simplifications were tried on a plate geometry. These simplifications related various modelling points with a correct plastic flow representation in the plate. The use of a reduced number of thermal fields characterising the bead deposit and a low number of tensile curves allow to obtain interesting results, decreasing significantly the Computing times. In addition various lumping bead methods have been studied and concerning both the shape and the thermic of the macro-deposits. The macro-deposit shapes studied are in 'L', or in layer or they represent two beads one on top of the other. Among these three methods, only those using a few number of lumping beads gave bad results since thermo-mechanical history was deeply modified near and inside the weld. Thereafter, simplified methods have been applied to a tubular geometry. On this new geometry, experimental measurements were made during welding, which allow a validation of the reference calculation. Simplified and reference calculations gave approximately the same stress fields as found on plate geometry. Finally, in the last part of this document a procedure for automatic data setting permitting to reduce significantly the calculation phase preparation is presented. It has been applied to the calculation of thick pipe welding in 90 beads; the results are compared with a simplified simulation realised by Framatome and with experimental measurements. A bead by

  7. Lesion insertion in the projection domain: Methods and initial results

    International Nuclear Information System (INIS)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia

    2015-01-01

    Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically

  8. Lesion insertion in the projection domain: Methods and initial results

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia, E-mail: mccollough.cynthia@mayo.edu [Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2015-12-15

    Purpose: To perform task-based image quality assessment in CT, it is desirable to have a large number of realistic patient images with known diagnostic truth. One effective way of achieving this objective is to create hybrid images that combine patient images with inserted lesions. Because conventional hybrid images generated in the image domain fails to reflect the impact of scan and reconstruction parameters on lesion appearance, this study explored a projection-domain approach. Methods: Lesions were segmented from patient images and forward projected to acquire lesion projections. The forward-projection geometry was designed according to a commercial CT scanner and accommodated both axial and helical modes with various focal spot movement patterns. The energy employed by the commercial CT scanner for beam hardening correction was measured and used for the forward projection. The lesion projections were inserted into patient projections decoded from commercial CT projection data. The combined projections were formatted to match those of commercial CT raw data, loaded onto a commercial CT scanner, and reconstructed to create the hybrid images. Two validations were performed. First, to validate the accuracy of the forward-projection geometry, images were reconstructed from the forward projections of a virtual ACR phantom and compared to physically acquired ACR phantom images in terms of CT number accuracy and high-contrast resolution. Second, to validate the realism of the lesion in hybrid images, liver lesions were segmented from patient images and inserted back into the same patients, each at a new location specified by a radiologist. The inserted lesions were compared to the original lesions and visually assessed for realism by two experienced radiologists in a blinded fashion. Results: For the validation of the forward-projection geometry, the images reconstructed from the forward projections of the virtual ACR phantom were consistent with the images physically

  9. A method of knowledge base verification and validation for nuclear power plants expert systems

    International Nuclear Information System (INIS)

    Kwon, Il Won

    1996-02-01

    The adoption of expert systems mainly as operator supporting systems is becoming increasingly popular as the control algorithms of system become more and more sophisticated and complicated. As a result of this popularity, a large number of expert systems are developed. The nature of expert systems, however, requires that they be verified and validated carefully and that detailed methodologies for their development be devised. Therefore, it is widely noted that assuring the reliability of expert systems is very important, especially in nuclear industry, and it is also recognized that the process of verification and validation is an essential part of reliability assurance for these systems. Research and practices have produced numerous methods for expert system verification and validation (V and V) that suggest traditional software and system approaches to V and V. However, many approaches and methods for expert system V and V are partial, unreliable, and not uniform. The purpose of this paper is to present a new approach to expert system V and V, based on Petri nets, providing a uniform model. We devise and suggest an automated tool, called COKEP (Checker Of Knowledge base using Extended Petri net), for checking incorrectness, inconsistency, and incompleteness in a knowledge base. We also suggest heuristic analysis for validation process to show that the reasoning path is correct

  10. Developing and validating a nutrition knowledge questionnaire: key methods and considerations.

    Science.gov (United States)

    Trakman, Gina Louise; Forsyth, Adrienne; Hoye, Russell; Belski, Regina

    2017-10-01

    To outline key statistical considerations and detailed methodologies for the development and evaluation of a valid and reliable nutrition knowledge questionnaire. Literature on questionnaire development in a range of fields was reviewed and a set of evidence-based guidelines specific to the creation of a nutrition knowledge questionnaire have been developed. The recommendations describe key qualitative methods and statistical considerations, and include relevant examples from previous papers and existing nutrition knowledge questionnaires. Where details have been omitted for the sake of brevity, the reader has been directed to suitable references. We recommend an eight-step methodology for nutrition knowledge questionnaire development as follows: (i) definition of the construct and development of a test plan; (ii) generation of the item pool; (iii) choice of the scoring system and response format; (iv) assessment of content validity; (v) assessment of face validity; (vi) purification of the scale using item analysis, including item characteristics, difficulty and discrimination; (vii) evaluation of the scale including its factor structure and internal reliability, or Rasch analysis, including assessment of dimensionality and internal reliability; and (viii) gathering of data to re-examine the questionnaire's properties, assess temporal stability and confirm construct validity. Several of these methods have previously been overlooked. The measurement of nutrition knowledge is an important consideration for individuals working in the nutrition field. Improved methods in the development of nutrition knowledge questionnaires, such as the use of factor analysis or Rasch analysis, will enable more confidence in reported measures of nutrition knowledge.

  11. Summary of Validation of Multi-Pesticide Methods for Various Pesticide Formulations

    Energy Technology Data Exchange (ETDEWEB)

    Ambrus, A. [Hungarian Food Safety Office, Budapest (Hungary)

    2009-07-15

    The validation of multi-pesticide methods applicable for various types of pesticide formulations is treated. In a worked-out practical example, i.e. lambda cyhalothrin, the theoretical considerations outlined in the General Guidance section are put into practice. GC conditions, selection of an internal standard and criteria for an acceptable repeatability of injections are outlined, followed by sample preparation, calibration, batch analysis and confirmation of results through comparison using different separation columns. Complete sets of data are displayed in tabular form for other pesticide active ingredients and real formulations. (author)

  12. Validity Evaluation of the Assessment Method for Postural Loading on the Upper Body in Printing Industry

    Directory of Open Access Journals (Sweden)

    Mohammad Khandan

    2016-07-01

    Full Text Available Background and Objectives: Musculoskeletal disorders and injuries are known as a global occupational challenge. These injuries are more are concentrated in the upper limb. There are several methods to assess this kind of disorders, each of which have different efficiencies for various jobs based on their strengths and weaknesses. This study aimed to assess the validity of LUBA method in order to evaluate risk factors for musculoskeletal disorders in a printing industry in Qom province, 2014. Methods: In this descriptive cross-sectional study, all operational workers (n=94 were investigated in 2014. Nordic Musculoskeletal Questionnaire (NMQ was used to collect data on musculoskeletal disorders. We also used LUBA method to analyze postures in four different parts of the body (neck, shoulder, elbow, and wrist. The obtained data were analyzed using Mann-Whitney, Kruskal Wallis, and Kappa agreement tests. Results: Lumbar region of back with 35.1% prevalence had the most problems. The results of LUBA method showed that most postures were located at the second corrective action level, and need further studies. Agreement between assessment of shoulder posture and its disorders was significant (p0.05.  Conclusion: According to the results of this study on reliability and predictive validity of the LUBA method in printing industry, it can be concluded that this method is not a reliable method for posture assessment; however, further and more comprehensive studies are recommended.  

  13. A Fuzzy Logic Based Method for Analysing Test Results

    Directory of Open Access Journals (Sweden)

    Le Xuan Vinh

    2017-11-01

    Full Text Available Network operators must perform many tasks to ensure smooth operation of the network, such as planning, monitoring, etc. Among those tasks, regular testing of network performance, network errors and troubleshooting is very important. Meaningful test results will allow the operators to evaluate network performanceof any shortcomings and to better plan for network upgrade. Due to the diverse and mainly unquantifiable nature of network testing results, there is a needs to develop a method for systematically and rigorously analysing these results. In this paper, we present STAM (System Test-result Analysis Method which employs a bottom-up hierarchical processing approach using Fuzzy logic. STAM is capable of combining all test results into a quantitative description of the network performance in terms of network stability, the significance of various network erros, performance of each function blocks within the network. The validity of this method has been successfully demonstrated in assisting the testing of a VoIP system at the Research Instiute of Post and Telecoms in Vietnam. The paper is organized as follows. The first section gives an overview of fuzzy logic theory the concepts of which will be used in the development of STAM. The next section describes STAM. The last section, demonstrating STAM’s capability, presents a success story in which STAM is successfully applied.

  14. High-throughput screening assay used in pharmacognosy: Selection, optimization and validation of methods of enzymatic inhibition by UV-visible spectrophotometry

    Directory of Open Access Journals (Sweden)

    Graciela Granados-Guzmán

    2014-02-01

    Full Text Available In research laboratories of both organic synthesis and extraction of natural products, every day a lot of products that can potentially introduce some biological activity are obtained. Therefore it is necessary to have in vitro assays, which provide reliable information for further evaluation in in vivo systems. From this point of view, in recent years has intensified the use of high-throughput screening assays. Such trials should be optimized and validated for accurate and precise results, i.e. reliable. The present review addresses the steps needed to develop and validate bioanalytical methods, emphasizing UV-Visible spectrophotometry as detection system. Particularly focuses on the selection of the method, the optimization to determine the best experimental conditions, validation, implementation of optimized and validated method to real samples, and finally maintenance and possible transfer it to a new laboratory.

  15. Validation and Clinical Evaluation of a Novel Method To Measure Miltefosine in Leishmaniasis Patients Using Dried Blood Spot Sample Collection

    Science.gov (United States)

    Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.

    2016-01-01

    To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691

  16. Validity of a manual soft tissue profile prediction method following mandibular setback osteotomy.

    Science.gov (United States)

    Kolokitha, Olga-Elpis

    2007-10-01

    The aim of this study was to determine the validity of a manual cephalometric method used for predicting the post-operative soft tissue profiles of patients who underwent mandibular setback surgery and compare it to a computerized cephalometric prediction method (Dentofacial Planner). Lateral cephalograms of 18 adults with mandibular prognathism taken at the end of pre-surgical orthodontics and approximately one year after surgery were used. To test the validity of the manual method the prediction tracings were compared to the actual post-operative tracings. The Dentofacial Planner software was used to develop the computerized post-surgical prediction tracings. Both manual and computerized prediction printouts were analyzed by using the cephalometric system PORDIOS. Statistical analysis was performed by means of t-test. Comparison between manual prediction tracings and the actual post-operative profile showed that the manual method results in more convex soft tissue profiles; the upper lip was found in a more prominent position, upper lip thickness was increased and, the mandible and lower lip were found in a less posterior position than that of the actual profiles. Comparison between computerized and manual prediction methods showed that in the manual method upper lip thickness was increased, the upper lip was found in a more anterior position and the lower anterior facial height was increased as compared to the computerized prediction method. Cephalometric simulation of post-operative soft tissue profile following orthodontic-surgical management of mandibular prognathism imposes certain limitations related to the methods implied. However, both manual and computerized prediction methods remain a useful tool for patient communication.

  17. Validation of uncertainty of weighing in the preparation of radionuclide standards by Monte Carlo Method

    International Nuclear Information System (INIS)

    Cacais, F.L.; Delgado, J.U.; Loayza, V.M.

    2016-01-01

    In preparing solutions for the production of radionuclide metrology standards is necessary measuring the quantity Activity by mass. The gravimetric method by elimination is applied to perform weighing with smaller uncertainties. At this work is carried out the validation, by the Monte Carlo method, of the uncertainty calculation approach implemented by Lourenco and Bobin according to ISO GUM for the method by elimination. The results obtained by both uncertainty calculation methods were consistent indicating that were fulfilled the conditions for the application of ISO GUM in the preparation of radioactive standards. (author)

  18. Development of a validated HPLC method for the determination of sennoside A and B, two major constituents of Cassia obovata Coll.

    Directory of Open Access Journals (Sweden)

    Ghassemi-Dehkordi Nasrollah

    2014-04-01

    Full Text Available Introduction: Cassia obovata Coll is the only Senna species which grows wild in Iran. In the present study, an optimised reverse High Performance Liquid Chromatography (HPLC validated method was established for quantification of sennosides A and B, the major constituents of C. obovata with a simple and accurate method. Methods: HPLC analysis was done using Waters 515 pump on a Nova-Pak C18 (3.9 × 150 mm. Millennium software was used for the determination of the sennoside A and B in Cassia species and processing the information. The method was validated according to USP 32 requirements. Results: The solvent impact on the selectivity factor and partition coefficient parameters evaluated. Using a conventional RP-18 L1 column, 3.9 × 150 mm, the mobile phase was selected after several trials with different mixtures of water and acetonitrile. Sennosides A and B were determined using the external standard calibration method. Using USP 35-NF 30, the LOD and LOQ were calculated. The reliability of the HPLC-method for analysis of sennoside A + B was validated through its linearity, reproducibility, repeatability, and recovery. Fina1ly ethanol:water (1:1 extracts of Cassia obovata and Cassia angustifolia were standardized by assay of sennoside A and B through above HPLC validated method. Conclusion: Through the above method, determination of sennosides in Cassia species are completely possible. Moreover, through comparing the results, even though sennosides are rich in Cassia angustifolia but, the results shows that C. obovata could be considered as an alternative source for sennosides A and B.

  19. Validation of a method for radionuclide activity optimize in SPECT

    International Nuclear Information System (INIS)

    Perez Diaz, M.; Diaz Rizo, O.; Lopez Diaz, A.; Estevez Aparicio, E.; Roque Diaz, R.

    2007-01-01

    A discriminant method for optimizing the activity administered in NM studies is validated by comparison with ROC curves. the method is tested in 21 SPECT, performed with a Cardiac phantom. Three different cold lesions (L1, L2 and L3) were placed in the myocardium-wall for each SPECT. Three activities (84 MBq, 37 MBq or 18.5 MBq) of Tc-99m diluted in water were used as background. The linear discriminant analysis was used to select the parameters that characterize image quality (Background-to-Lesion (B/L) and Signal-to-Noise (S/N) ratios). Two clusters with different image quality (p=0.021) were obtained following the selected variables. the first one involved the studies performed with 37 MBq and 84 MBq, and the second one included the studies with 18.5 MBq. the ratios B/L, B/L2 and B/L3 are the parameters capable to construct the function, with 100% of cases correctly classified into the clusters. The value of 37 MBq is the lowest tested activity for which good results for the B/Li variables were obtained,without significant differences from the results with 84 MBq (p>0.05). The result is coincident with the applied ROC-analysis. A correlation between both method of r=890 was obtained. (Author) 26 refs

  20. Reliability and Validity of the Footprint Assessment Method Using Photoshop CS5 Software.

    Science.gov (United States)

    Gutiérrez-Vilahú, Lourdes; Massó-Ortigosa, Núria; Costa-Tutusaus, Lluís; Guerra-Balic, Myriam

    2015-05-01

    Several sophisticated methods of footprint analysis currently exist. However, it is sometimes useful to apply standard measurement methods of recognized evidence with an easy and quick application. We sought to assess the reliability and validity of a new method of footprint assessment in a healthy population using Photoshop CS5 software (Adobe Systems Inc, San Jose, California). Forty-two footprints, corresponding to 21 healthy individuals (11 men with a mean ± SD age of 20.45 ± 2.16 years and 10 women with a mean ± SD age of 20.00 ± 1.70 years) were analyzed. Footprints were recorded in static bipedal standing position using optical podography and digital photography. Three trials for each participant were performed. The Hernández-Corvo, Chippaux-Smirak, and Staheli indices and the Clarke angle were calculated by manual method and by computerized method using Photoshop CS5 software. Test-retest was used to determine reliability. Validity was obtained by intraclass correlation coefficient (ICC). The reliability test for all of the indices showed high values (ICC, 0.98-0.99). Moreover, the validity test clearly showed no difference between techniques (ICC, 0.99-1). The reliability and validity of a method to measure, assess, and record the podometric indices using Photoshop CS5 software has been demonstrated. This provides a quick and accurate tool useful for the digital recording of morphostatic foot study parameters and their control.

  1. Method for Determining Volumetric Efficiency and Its Experimental Validation

    Directory of Open Access Journals (Sweden)

    Ambrozik Andrzej

    2017-12-01

    Full Text Available Modern means of transport are basically powered by piston internal combustion engines. Increasingly rigorous demands are placed on IC engines in order to minimise the detrimental impact they have on the natural environment. That stimulates the development of research on piston internal combustion engines. The research involves experimental and theoretical investigations carried out using computer technologies. While being filled, the cylinder is considered to be an open thermodynamic system, in which non-stationary processes occur. To make calculations of thermodynamic parameters of the engine operating cycle, based on the comparison of cycles, it is necessary to know the mean constant value of cylinder pressure throughout this process. Because of the character of in-cylinder pressure pattern and difficulties in pressure experimental determination, in the present paper, a novel method for the determination of this quantity was presented. In the new approach, the iteration method was used. In the method developed for determining the volumetric efficiency, the following equations were employed: the law of conservation of the amount of substance, the first law of thermodynamics for open system, dependences for changes in the cylinder volume vs. the crankshaft rotation angle, and the state equation. The results of calculations performed with this method were validated by means of experimental investigations carried out for a selected engine at the engine test bench. A satisfactory congruence of computational and experimental results as regards determining the volumetric efficiency was obtained. The method for determining the volumetric efficiency presented in the paper can be used to investigate the processes taking place in the cylinder of an IC engine.

  2. Probability of Detection (POD) as a statistical model for the validation of qualitative methods.

    Science.gov (United States)

    Wehling, Paul; LaBudde, Robert A; Brunelle, Sharon L; Nelson, Maria T

    2011-01-01

    A statistical model is presented for use in validation of qualitative methods. This model, termed Probability of Detection (POD), harmonizes the statistical concepts and parameters between quantitative and qualitative method validation. POD characterizes method response with respect to concentration as a continuous variable. The POD model provides a tool for graphical representation of response curves for qualitative methods. In addition, the model allows comparisons between candidate and reference methods, and provides calculations of repeatability, reproducibility, and laboratory effects from collaborative study data. Single laboratory study and collaborative study examples are given.

  3. Optimization, validation and application of UV-Vis spectrophotometric-colorimetric methods for determination of trimethoprim in different medicinal products

    Directory of Open Access Journals (Sweden)

    Goran Stojković

    2016-03-01

    Full Text Available Two simple, sensitive, selective, precise, and accurate methods for determination of trimethoprim in different sulfonamide formulations intended for use in human and veterinary medicine were optimized and validated. The methods are based on the trimethoprim reaction with bromcresol green (BCG and 2,4-dinitro-1-fluorobenzene (DNFB. As extraction solvents we used 10 % N,N-dimethylacetamide in methanol and acetone for both methods, respectively. The colored products are quantified applying visible spectrophotometry at their corresponding absorption maxima. The methods were validated for linearity, sensitivity, accuracy, and precision. We tested the method applicability on four different medicinal products in tablet and powder forms containing sulfametrole and sulfamethoxazole in combination with trimethoprim. The results revealed that both methods are equally accurate with recoveries within the range 95-105 %. The obtained between-day precision for both methods, when applied on four different medicinal products, was within in the range 1.08-3.20 %. By applying the F-statistical test (P<0.05, it was concluded that for three medicinal products tested both methods are applicable with statistically insignificant difference in precision. The optimized and validated BCG and DNFB methods could find application in routine quality control of trimethoprim in various formulation forms, at different concentration levels, and in combination with different sulfonamides.

  4. SPE HG-AAS method for the determination of inorganic arsenic in rice—results from method validation studies and a survey on rice products

    DEFF Research Database (Denmark)

    Rasmussen, Rie Romme; Qian, Yiting; Sloth, Jens Jørgen

    2013-01-01

    spectrometry (HG-AAS) detection. This approach was earlier developed for seafood samples (Rasmussen et al., Anal Bioanal Chem 403:2825–2834, 2012) and has in the present work been tailored for rice products and further optimised for a higher sample throughput and a lower detection limit. Water bath heating (90...... °C, 60 min) of samples with dilute HNO3 and H2O2 solubilised and oxidised all iAs to arsenate (AsV). Loading of buffered sample extracts (pH 6 ± 1) followed by selective elution of arsenate from a strong anion exchange SPE cartridge enabled the selective iAs quantification by HG-AAS, measuring total...... arsenic (As) in the SPE eluate. The in-house validation gave mean recoveries of 101–106 % for spiked rice samples and in two reference samples. The limit of detection was 0.02 mg kg−1, and repeatability and intra-laboratory reproducibility were less than 6 and 9 %, respectively. The SPE HG-AAS method...

  5. Validation Test Results for Orthogonal Probe Eddy Current Thruster Inspection System

    Science.gov (United States)

    Wincheski, Russell A.

    2007-01-01

    Recent nondestructive evaluation efforts within NASA have focused on an inspection system for the detection of intergranular cracking originating in the relief radius of Primary Reaction Control System (PCRS) Thrusters. Of particular concern is deep cracking in this area which could lead to combustion leakage in the event of through wall cracking from the relief radius into an acoustic cavity of the combustion chamber. In order to reliably detect such defects while ensuring minimal false positives during inspection, the Orthogonal Probe Eddy Current (OPEC) system has been developed and an extensive validation study performed. This report describes the validation procedure, sample set, and inspection results as well as comparing validation flaws with the response from naturally occuring damage.

  6. In Vitro Dissolution Profile of Dapagliflozin: Development, Method Validation, and Analysis of Commercial Tablets

    Directory of Open Access Journals (Sweden)

    Rafaela Zielinski Cavalheiro de Meira

    2017-01-01

    Full Text Available Dapagliflozin was the first of its class (inhibitors of sodium-glucose cotransporter to be approved in Europe, USA, and Brazil. As the drug was recently approved, there is the need for research on analytical methods, including dissolution studies for the quality evaluation and assurance of tablets. The dissolution methodology was developed with apparatus II (paddle in 900 mL of medium (simulated gastric fluid, pH 1.2, temperature set at 37±0.5°C, and stirring speed of 50 rpm. For the quantification, a spectrophotometric (λ=224 nm method was developed and validated. In validation studies, the method proved to be specific and linear in the range from 0.5 to 15 μg·mL−1 (r2=0.998. The precision showed results with RSD values lower than 2%. The recovery of 80.72, 98.47, and 119.41% proved the accuracy of the method. Through a systematic approach by applying Factorial 23, the robustness of the method was confirmed (p>0.05. The studies of commercial tablets containing 5 or 10 mg demonstrated that they could be considered similar through f1, f2, and dissolution efficiency analyses. Also, the developed method can be used for the quality evaluation of dapagliflozin tablets and can be considered as a scientific basis for future official pharmacopoeial methods.

  7. Validation of ultraviolet method to determine serum phosphorus level

    International Nuclear Information System (INIS)

    Garcia Borges, Lisandra; Perez Prieto, Teresa Maria; Valdes Diez, Lilliam

    2009-01-01

    Validation of a spectrophotometry method applicable in clinic labs was proposed to analytical assessment of serum phosphates using a kit UV-phosphorus of domestic production from 'Carlos J. Finlay' Biologics Production Enterprise (Havana, Cuba). Analysis method was based on phosphorus reaction to ammonium molybdenum to acid pH to creating a measurable complex to 340 nm. Specificity and precision were measured considering the method strength, linearity, accuracy and sensitivity. Analytical method was linear up to 4,8 mmol/L, precise (CV 30 .999) during clinical interest concentration interval where there were not interferences by matrix. Detection limit values were of 0.037 mmol/L and of quantification of 0.13 mmol/L both were satisfactory for product use

  8. A photographic method to measure food item intake. Validation in geriatric institutions.

    Science.gov (United States)

    Pouyet, Virginie; Cuvelier, Gérard; Benattar, Linda; Giboreau, Agnès

    2015-01-01

    From both a clinical and research perspective, measuring food intake is an important issue in geriatric institutions. However, weighing food in this context can be complex, particularly when the items remaining on a plate (side dish, meat or fish and sauce) need to be weighed separately following consumption. A method based on photography that involves taking photographs after a meal to determine food intake consequently seems to be a good alternative. This method enables the storage of raw data so that unhurried analyses can be performed to distinguish the food items present in the images. Therefore, the aim of this paper was to validate a photographic method to measure food intake in terms of differentiating food item intake in the context of a geriatric institution. Sixty-six elderly residents took part in this study, which was performed in four French nursing homes. Four dishes of standardized portions were offered to the residents during 16 different lunchtimes. Three non-trained assessors then independently estimated both the total and specific food item intakes of the participants using images of their plates taken after the meal (photographic method) and a reference image of one plate taken before the meal. Total food intakes were also recorded by weighing the food. To test the reliability of the photographic method, agreements between different assessors and agreements among various estimates made by the same assessor were evaluated. To test the accuracy and specificity of this method, food intake estimates for the four dishes were compared with the food intakes determined using the weighed food method. To illustrate the added value of the photographic method, food consumption differences between the dishes were explained by investigating the intakes of specific food items. Although they were not specifically trained for this purpose, the results demonstrated that the assessor estimates agreed between assessors and among various estimates made by the same

  9. Model validation of solar PV plant with hybrid data dynamic simulation based on fast-responding generator method

    Directory of Open Access Journals (Sweden)

    Zhao Dawei

    2016-01-01

    Full Text Available In recent years, a significant number of large-scale solar photovoltaic (PV plants have been put into operation or been under planning around the world. The model accuracy of solar PV plant is the key factor to investigate the mutual influences between solar PV plants and a power grid. However, this problem has not been well solved, especially in how to apply the real measurements to validate the models of the solar PV plants. Taking fast-responding generator method as an example, this paper presents a model validation methodology for solar PV plant via the hybrid data dynamic simulation. First, the implementation scheme of hybrid data dynamic simulation suitable for DIgSILENT PowerFactory software is proposed, and then an analysis model of solar PV plant integration based on IEEE 9 system is established. At last, model validation of solar PV plant is achieved by employing hybrid data dynamic simulation. The results illustrate the effectiveness of the proposed method in solar PV plant model validation.

  10. Critical Values for Lawshe's Content Validity Ratio: Revisiting the Original Methods of Calculation

    Science.gov (United States)

    Ayre, Colin; Scally, Andrew John

    2014-01-01

    The content validity ratio originally proposed by Lawshe is widely used to quantify content validity and yet methods used to calculate the original critical values were never reported. Methods for original calculation of critical values are suggested along with tables of exact binomial probabilities.

  11. Comparison of the Effects of Cross-validation Methods on Determining Performances of Classifiers Used in Diagnosing Congestive Heart Failure

    Directory of Open Access Journals (Sweden)

    Isler Yalcin

    2015-08-01

    Full Text Available Congestive heart failure (CHF occurs when the heart is unable to provide sufficient pump action to maintain blood flow to meet the needs of the body. Early diagnosis is important since the mortality rate of the patients with CHF is very high. There are different validation methods to measure performances of classifier algorithms designed for this purpose. In this study, k-fold and leave-one-out cross-validation methods were tested for performance measures of five distinct classifiers in the diagnosis of the patients with CHF. Each algorithm was run 100 times and the average and the standard deviation of classifier performances were recorded. As a result, it was observed that average performance was enhanced and the variability of performances was decreased when the number of data sections used in the cross-validation method was increased.

  12. Validation of the method for investigation of radiopharmaceuticals for in vitro use

    International Nuclear Information System (INIS)

    Vranjes, S; Jovanovic, M.; Orlic, M.; Lazic, E. . E-mail address of corresponding author: sanjav@vin.bg.ac.yu

    2005-01-01

    The aim of this study was to validate analytical method for determination of total radioactivity and radioactive concentration of 125 I-triiodotironin, radiopharmaceutical for in vitro use. Analytical parameters: selectivity, accuracy, linearity and range of this method were determined. Values obtained for all parameters are reasonable for analytical methods, therefore this method could be used for farther investigation. (author)

  13. Software phantom with realistic speckle modeling for validation of image analysis methods in echocardiography

    Science.gov (United States)

    Law, Yuen C.; Tenbrinck, Daniel; Jiang, Xiaoyi; Kuhlen, Torsten

    2014-03-01

    Computer-assisted processing and interpretation of medical ultrasound images is one of the most challenging tasks within image analysis. Physical phenomena in ultrasonographic images, e.g., the characteristic speckle noise and shadowing effects, make the majority of standard methods from image analysis non optimal. Furthermore, validation of adapted computer vision methods proves to be difficult due to missing ground truth information. There is no widely accepted software phantom in the community and existing software phantoms are not exible enough to support the use of specific speckle models for different tissue types, e.g., muscle and fat tissue. In this work we propose an anatomical software phantom with a realistic speckle pattern simulation to _ll this gap and provide a exible tool for validation purposes in medical ultrasound image analysis. We discuss the generation of speckle patterns and perform statistical analysis of the simulated textures to obtain quantitative measures of the realism and accuracy regarding the resulting textures.

  14. DEVELOPMENT AND VALIDATION OF NUMERICAL METHOD FOR STRENGTH ANALYSIS OF LATTICE COMPOSITE FUSELAGE STRUCTURES

    Directory of Open Access Journals (Sweden)

    2016-01-01

    Full Text Available Lattice composite fuselage structures are developed as an alternative to conventional composite structures based on laminated skin and stiffeners. Structure layout of lattice structures allows to realize advantages of current composite materials to a maximal extent, at the same time minimizing their main shortcomings, that allows to provide higher weight efficiency for these structures in comparison with conventional analogues.Development and creation of lattice composite structures requires development of novel methods of strength anal- ysis, as conventional methods, as a rule, are aiming to strength analysis of thin-walled elements and do not allow to get confident estimation of local strength of high-loaded unidirectional composite ribs.In the present work the method of operative strength analysis of lattice composite structure is presented, based onspecialized FE-models of unidirectional composite ribs and their intersections. In the frames of the method, every rib is modeled by a caisson structure, consisting of arbitrary number of flanges and webs, modeled by membrane finite elements. Parameters of flanges and webs are calculated automatically from the condition of stiffness characteristics equality of real rib and the model. This method allows to perform local strength analysis of high-loaded ribs of lattice structure without use of here-dimensional finite elements, that allows to shorten time of calculations and sufficiently simplify the procedure of analysis of results of calculations.For validation of the suggested method, the results of experimental investigations of full-scale prototype of shell of lattice composite fuselage section have been used. The prototype of the lattice section was manufactured in CRISM and tested in TsAGI within the frames of a number of Russian and International scientific projects. The results of validation have shown that the suggested method allows to provide high operability of strength analysis, keeping

  15. A new method for assessing content validity in model-based creation and iteration of eHealth interventions.

    Science.gov (United States)

    Kassam-Adams, Nancy; Marsac, Meghan L; Kohser, Kristen L; Kenardy, Justin A; March, Sonja; Winston, Flaura K

    2015-04-15

    The advent of eHealth interventions to address psychological concerns and health behaviors has created new opportunities, including the ability to optimize the effectiveness of intervention activities and then deliver these activities consistently to a large number of individuals in need. Given that eHealth interventions grounded in a well-delineated theoretical model for change are more likely to be effective and that eHealth interventions can be costly to develop, assuring the match of final intervention content and activities to the underlying model is a key step. We propose to apply the concept of "content validity" as a crucial checkpoint to evaluate the extent to which proposed intervention activities in an eHealth intervention program are valid (eg, relevant and likely to be effective) for the specific mechanism of change that each is intended to target and the intended target population for the intervention. The aims of this paper are to define content validity as it applies to model-based eHealth intervention development, to present a feasible method for assessing content validity in this context, and to describe the implementation of this new method during the development of a Web-based intervention for children. We designed a practical 5-step method for assessing content validity in eHealth interventions that includes defining key intervention targets, delineating intervention activity-target pairings, identifying experts and using a survey tool to gather expert ratings of the relevance of each activity to its intended target, its likely effectiveness in achieving the intended target, and its appropriateness with a specific intended audience, and then using quantitative and qualitative results to identify intervention activities that may need modification. We applied this method during our development of the Coping Coach Web-based intervention for school-age children. In the evaluation of Coping Coach content validity, 15 experts from five countries

  16. Validation of a multi-residue method for the determination of several antibiotic groups in honey by LC-MS/MS.

    Science.gov (United States)

    Bohm, Detlef A; Stachel, Carolin S; Gowik, Petra

    2012-07-01

    The presented multi-method was developed for the confirmation of 37 antibiotic substances from the six antibiotic groups: macrolides, lincosamides, quinolones, tetracyclines, pleuromutilines and diamino-pyrimidine derivatives. All substances were analysed simultaneously in a single analytical run with the same procedure, including an extraction with buffer, a clean-up by solid-phase extraction, and the measurement by liquid chromatography tandem mass spectrometry in ESI+ mode. The method was validated on the basis of an in-house validation concept with factorial design by combination of seven factors to check the robustness in a concentration range of 5-50 μg kg(-1). The honeys used were of different types with regard to colour and origin. The values calculated for the validation parameters-decision limit CCα (range, 7.5-12.9 μg kg(-1)), detection capability CCβ (range, 9.4-19.9 μg kg(-1)), within-laboratory reproducibility RSD(wR) (tylvalosin with 21.4 %), repeatability RSD(r) (tylvalosin with 21.1%), and recovery (range, 92-106%)-were acceptable and in agreement with the criteria of Commission Decision 2002/657/EC. The validation results showed that the method was applicable for the residue analysis of antibiotics in honey to substances with and without recommended concentrations, although some changes had been tested during validation to determine the robustness of the method.

  17. Teaching Analytical Method Transfer through Developing and Validating Then Transferring Dissolution Testing Methods for Pharmaceuticals

    Science.gov (United States)

    Kimaru, Irene; Koether, Marina; Chichester, Kimberly; Eaton, Lafayette

    2017-01-01

    Analytical method transfer (AMT) and dissolution testing are important topics required in industry that should be taught in analytical chemistry courses. Undergraduate students in senior level analytical chemistry laboratory courses at Kennesaw State University (KSU) and St. John Fisher College (SJFC) participated in development, validation, and…

  18. Statistical Analysis Methods for Physics Models Verification and Validation

    CERN Document Server

    De Luca, Silvia

    2017-01-01

    The validation and verification process is a fundamental step for any software like Geant4 and GeantV, which aim to perform data simulation using physics models and Monte Carlo techniques. As experimental physicists, we have to face the problem to compare the results obtained using simulations with what the experiments actually observed. One way to solve the problem is to perform a consistency test. Within the Geant group, we developed a C++ compact library which will be added to the automated validation process on the Geant Validation Portal

  19. ReSOLV: Applying Cryptocurrency Blockchain Methods to Enable Global Cross-Platform Software License Validation

    Directory of Open Access Journals (Sweden)

    Alan Litchfield

    2018-05-01

    Full Text Available This paper presents a method for a decentralised peer-to-peer software license validation system using cryptocurrency blockchain technology to ameliorate software piracy, and to provide a mechanism for software developers to protect copyrighted works. Protecting software copyright has been an issue since the late 1970s and software license validation has been a primary method employed in an attempt to minimise software piracy and protect software copyright. The method described creates an ecosystem in which the rights and privileges of participants are observed.

  20. Development and validation of a stability-indicating capillary zone electrophoretic method for the assessment of entecavir and its correlation with liquid chromatographic methods.

    Science.gov (United States)

    Dalmora, Sergio Luiz; Nogueira, Daniele Rubert; D'Avila, Felipe Bianchini; Souto, Ricardo Bizogne; Leal, Diogo Paim

    2011-01-01

    A stability-indicating capillary zone electrophoresis (CZE) method was validated for the analysis of entecavir in pharmaceutical formulations, using nimesulide as an internal standard. A fused-silica capillary (50 µm i.d.; effective length, 40 cm) was used while being maintained at 25°C; the applied voltage was 25 kV. A background electrolyte solution consisted of a 20 mM sodium tetraborate solution at pH 10. Injections were performed using a pressure mode at 50 mbar for 5 s, with detection at 216 nm. The specificity and stability-indicating capability were proven through forced degradation studies, evaluating also the in vitro cytotoxicity test of the degraded products. The method was linear over the concentration range of 1-200 µg mL(-1) (r(2) = 0.9999), and was applied for the analysis of entecavir in tablet dosage forms. The results were correlated to those of validated conventional and fast LC methods, showing non-significant differences (p > 0.05).

  1. Contribution to the validation of thermal ratchetting prevision methods in metallic structures; Contribution a la validation des methodes de prevision du rochet thermique dans les structures metalliques

    Energy Technology Data Exchange (ETDEWEB)

    Rakotovelo, A.M

    1998-03-01

    This work concerns the steady state assessment in the metallic structures subjected to thermomechanical cyclic loadings in biaxial stress state. The effect of the short time mechanical overloads is also investigated. The first chapter is devoted to a bibliographic research concerning the behaviour of the materials and the structures in the cyclic plasticity. Some works relate to the experimental aspect as well as the numerical one for the steady state assessment of such structures are presented. The experimental part of the study is presented in the second chapter. The experimental device was carried out in order to prescribe tension and torsion forces combined with cyclic thermal loading. Some tests was then carried out, among these tests certain include some overloads in tension or torsion. The last chapter describes the numerical calculations using different models (linear isotropic hardening, linear kinematic hardening and elasto-viscoplastic Chaboche's model) and the application of some simplified methods for the ratchetting assessment in the structures. We have considered two categories of methods. The first one is based on an elastic analysis (Bree's diagram, 3 Sm rule, efficiency rule) and the second one combines elastic analysis and elastoplastic analysis of the first cycle (Gatt's and Taleb's methods). The results of this study have enabled: to validate in the biaxial stress state an expression which takes into account the effect of mechanical short time overloads; to test the performances of considered models to describe the evolution of the structure during the first cycle and to take into account the effect of short time overloads. Among the considered models, the elastoplastic Chaboche's model seems to be the most accurate to describe the structure's behaviour during the first cycles; to validate some simplified methods. Certain methods based only on elastic analysis (Bee's diagram and efficiency rule) seem not

  2. Method validation for determination of gadolinium (III) and diethyl tetraamine pentaacetic acid (DTPA) ligand amount determination in Gd-DTPA contrast agent

    International Nuclear Information System (INIS)

    Rien Ritawidya; Martalena Ramli; Cecep Taufik Rustendi

    2014-01-01

    Gd-DTPA is one of the contrast agent which is important in Magnetic Resonance Imaging (MRI) application. The presence of free Gd (III) ion and free DTPA ligand is extremely toxic in human body. Therefore, it needs a method in order to determine free ion Gd (III) and free DTPA ligand concentration which then MRI would be applicable for clinical purpose. The analytical method that selected for the research was complexometric titration. The research was carried out in order to make validation method of free ion Gd (III) and free DTPA ligand determination, then validation criteria such as % recovery, % coefisien of variance and linearity could be obtained. Some experiments that had been done on determination of free Gd (III) with DTPA resulted in % recovery between 30,33% - 183,59%, the precision from %CV between 2,34% - 35,25% and linearity showed with value of R = 0,9525. Meanwhile on determination of DTPA with Gd (III) resulted in % recovery between 105.15% - 139,12%, %CV between 6,78% - 10,96% and R = 0,9525. Validation result indicates that determination method can not be used as a method to determine free ion Gd(III) and free DTPA ligand in contrast agent. (author)

  3. Validation of a digital photographic method for assessment of dietary quality of school lunch sandwiches brought from home

    DEFF Research Database (Denmark)

    Sabinsky, Marianne; Toft, Ulla; Andersen, Klaus K

    2013-01-01

    Background: It is a challenge to assess children’s dietary intake. The digital photographic method (DPM) may be an objective method that can overcome some of these challenges. Objective: The aim of this study was to evaluate the validity and reliability of a DPM to assess the quality of dietary....... The lunches were photographed using a standardised DPM. From the digital images, the dietary components were estimated by a trained image analyst using weights or household measures and the dietary quality was assessed using a validated Meal Index of Dietary Quality (Meal IQ). The dietary components...... and the Meal IQ obtained from the digital images were validated against the objective weighed foods of the school lunch sandwiches. To determine interrater reliability, the digital images were evaluated by a second image analyst. Results: Correlation coefficients between the DPM and the weighed foods ranged...

  4. Determination of methylmercury in marine sediment samples: Method validation and occurrence data

    Energy Technology Data Exchange (ETDEWEB)

    Carrasco, Luis; Vassileva, Emilia, E-mail: e.vasileva-veleva@iaea.org

    2015-01-01

    Highlights: • A method for MeHg determination at trace level in marine sediments is completely validated. • Validation is performed according to ISO-17025 and Eurachem guidelines. • The extraction efficiency of four sample preparation procedures is evaluated. • The uncertainty budget is used as a tool for evaluation of main uncertainty contributors. • Comparison with independent methods yields good agreement within stated uncertainty. - Abstract: The determination of methylmercury (MeHg) in sediment samples is a difficult task due to the extremely low MeHg/THg (total mercury) ratio and species interconversion. Here, we present the method validation of a cost-effective fit-for-purpose analytical procedure for the measurement of MeHg in sediments, which is based on aqueous phase ethylation, followed by purge and trap and hyphenated gas chromatography–pyrolysis–atomic fluorescence spectrometry (GC–Py–AFS) separation and detection. Four different extraction techniques, namely acid and alkaline leaching followed by solvent extraction and evaporation, microwave-assisted extraction with 2-mercaptoethanol, and acid leaching, solvent extraction and back extraction into sodium thiosulfate, were examined regarding their potential to selectively extract MeHg from estuarine sediment IAEA-405 certified reference material (CRM). The procedure based on acid leaching with HNO{sub 3}/CuSO{sub 4}, solvent extraction and back extraction into Na{sub 2}S{sub 2}O{sub 3} yielded the highest extraction recovery, i.e., 94 ± 3% and offered the possibility to perform the extraction of a large number of samples in a short time, by eliminating the evaporation step. The artifact formation of MeHg was evaluated by high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry (HPLC–ICP–MS), using isotopically enriched Me{sup 201}Hg and {sup 202}Hg and it was found to be nonexistent. A full validation approach in line with ISO 17025 and

  5. Determination of methylmercury in marine sediment samples: Method validation and occurrence data

    International Nuclear Information System (INIS)

    Carrasco, Luis; Vassileva, Emilia

    2015-01-01

    Highlights: • A method for MeHg determination at trace level in marine sediments is completely validated. • Validation is performed according to ISO-17025 and Eurachem guidelines. • The extraction efficiency of four sample preparation procedures is evaluated. • The uncertainty budget is used as a tool for evaluation of main uncertainty contributors. • Comparison with independent methods yields good agreement within stated uncertainty. - Abstract: The determination of methylmercury (MeHg) in sediment samples is a difficult task due to the extremely low MeHg/THg (total mercury) ratio and species interconversion. Here, we present the method validation of a cost-effective fit-for-purpose analytical procedure for the measurement of MeHg in sediments, which is based on aqueous phase ethylation, followed by purge and trap and hyphenated gas chromatography–pyrolysis–atomic fluorescence spectrometry (GC–Py–AFS) separation and detection. Four different extraction techniques, namely acid and alkaline leaching followed by solvent extraction and evaporation, microwave-assisted extraction with 2-mercaptoethanol, and acid leaching, solvent extraction and back extraction into sodium thiosulfate, were examined regarding their potential to selectively extract MeHg from estuarine sediment IAEA-405 certified reference material (CRM). The procedure based on acid leaching with HNO 3 /CuSO 4 , solvent extraction and back extraction into Na 2 S 2 O 3 yielded the highest extraction recovery, i.e., 94 ± 3% and offered the possibility to perform the extraction of a large number of samples in a short time, by eliminating the evaporation step. The artifact formation of MeHg was evaluated by high performance liquid chromatography coupled to inductively coupled plasma mass spectrometry (HPLC–ICP–MS), using isotopically enriched Me 201 Hg and 202 Hg and it was found to be nonexistent. A full validation approach in line with ISO 17025 and Eurachem guidelines was followed

  6. Development and Validation of HPLC-PDA Assay method of Frangula emodin

    Directory of Open Access Journals (Sweden)

    Deborah Duca

    2016-03-01

    Full Text Available Frangula emodin, (1,3,8-trihydroxy-6-methyl-anthraquinone, is one of the anthraquinone derivatives found abundantly in the roots and bark of a number of plant families traditionally used to treat constipation and haemorrhoids. The present study describes the development and subsequent validation of a specific Assay HPLC method for emodin. The separation was achieved on a Waters Symmetry C18, 4.6 × 250 mm, 5 μm particle size, column at a temperature of 35 °C, with UV detection at 287 and 436 nm. An isocratic elution mode consisting of 0.1% formic acid and 0.01% trifluoroacetic acid as the aqueous mobile phase, and methanol was used. The method was successfully and statistically validated for linearity, range, precision, accuracy, specificity and solution stability.

  7. Development and validation of an ionic chromatography method for the determination of nitrate, nitrite and chloride in meat.

    Science.gov (United States)

    Lopez-Moreno, Cristina; Perez, Isabel Viera; Urbano, Ana M

    2016-03-01

    The purpose of this study is to develop the validation of a method for the analysis of certain preservatives in meat and to obtain a suitable Certified Reference Material (CRM) to achieve this task. The preservatives studied were NO3(-), NO2(-) and Cl(-) as they serve as important antimicrobial agents in meat to inhibit the growth of bacteria spoilage. The meat samples were prepared using a treatment that allowed the production of a known CRM concentration that is highly homogeneous and stable in time. The matrix effects were also studied to evaluate the influence on the analytical signal for the ions of interest, showing that the matrix influence does not affect the final result. An assessment of the signal variation in time was carried out for the ions. In this regard, although the chloride and nitrate signal remained stable for the duration of the study, the nitrite signal decreased appreciably with time. A mathematical treatment of the data gave a stable nitrite signal, obtaining a method suitable for the validation of these anions in meat. A statistical study was needed for the validation of the method, where the precision, accuracy, uncertainty and other mathematical parameters were evaluated obtaining satisfactory results. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Optimal Control of Diesel Engines: Numerical Methods, Applications, and Experimental Validation

    Directory of Open Access Journals (Sweden)

    Jonas Asprion

    2014-01-01

    become complex systems. The exploitation of any leftover potential during transient operation is crucial. However, even an experienced calibration engineer cannot conceive all the dynamic cross couplings between the many actuators. Therefore, a highly iterative procedure is required to obtain a single engine calibration, which in turn causes a high demand for test-bench time. Physics-based mathematical models and a dynamic optimisation are the tools to alleviate this dilemma. This paper presents the methods required to implement such an approach. The optimisation-oriented modelling of diesel engines is summarised, and the numerical methods required to solve the corresponding large-scale optimal control problems are presented. The resulting optimal control input trajectories over long driving profiles are shown to provide enough information to allow conclusions to be drawn for causal control strategies. Ways of utilising this data are illustrated, which indicate that a fully automated dynamic calibration of the engine control unit is conceivable. An experimental validation demonstrates the meaningfulness of these results. The measurement results show that the optimisation predicts the reduction of the fuel consumption and the cumulative pollutant emissions with a relative error of around 10% on highly transient driving cycles.

  9. Validation results of satellite mock-up capturing experiment using nets

    Science.gov (United States)

    Medina, Alberto; Cercós, Lorenzo; Stefanescu, Raluca M.; Benvenuto, Riccardo; Pesce, Vincenzo; Marcon, Marco; Lavagna, Michèle; González, Iván; Rodríguez López, Nuria; Wormnes, Kjetil

    2017-05-01

    The PATENDER activity (Net parametric characterization and parabolic flight), funded by the European Space Agency (ESA) via its Clean Space initiative, was aiming to validate a simulation tool for designing nets for capturing space debris. This validation has been performed through a set of different experiments under microgravity conditions where a net was launched capturing and wrapping a satellite mock-up. This paper presents the architecture of the thrown-net dynamics simulator together with the set-up of the deployment experiment and its trajectory reconstruction results on a parabolic flight (Novespace A-310, June 2015). The simulator has been implemented within the Blender framework in order to provide a highly configurable tool, able to reproduce different scenarios for Active Debris Removal missions. The experiment has been performed over thirty parabolas offering around 22 s of zero-g conditions. Flexible meshed fabric structure (the net) ejected from a container and propelled by corner masses (the bullets) arranged around its circumference have been launched at different initial velocities and launching angles using a pneumatic-based dedicated mechanism (representing the chaser satellite) against a target mock-up (the target satellite). High-speed motion cameras were recording the experiment allowing 3D reconstruction of the net motion. The net knots have been coloured to allow the images post-process using colour segmentation, stereo matching and iterative closest point (ICP) for knots tracking. The final objective of the activity was the validation of the net deployment and wrapping simulator using images recorded during the parabolic flight. The high-resolution images acquired have been post-processed to determine accurately the initial conditions and generate the reference data (position and velocity of all knots of the net along its deployment and wrapping of the target mock-up) for the simulator validation. The simulator has been properly

  10. Validation of an ergonomic method to withdraw [99mTc] radiopharmaceuticals.

    Science.gov (United States)

    Blondeel-Gomes, Sandy; Marie, Solène; Fouque, Julien; Loyeau, Sabrina; Madar, Olivier; Lokiec, François

    2017-11-10

    The main objective of the present work was to ensure quality of radiopharmaceuticals syringes withdrawn with a "Spinal needle/obturator In-Stopper" system. Methods: Visual examinations and physicochemical tests are performed at T0 and T+4h for [ 99m Tc]albumin nanocolloid and T+7h for [ 99m Tc]eluate, [ 99m Tc] HydroxyMethylene DiPhosphonate and [ 99m Tc]Human Serum Albumin. Microbiological validation was performed according to European pharmacopoeia. Fingertip radiation exposure was evaluated to confirm the safety of the system. Results: Results show stable visual and physicochemical properties. The integrity of the connector was not affected after 30 punctures (no cores). No microbiological contamination was found on tested syringes. Conclusion: The system could be used 30 times. The stability of syringes drawing with this method is guaranteed up to 4 hours for [ 99m Tc]albumin nanocolloid and 7 hours for [ 99m Tc]eluate, [ 99m Tc]HydroxyMethylene DisPhosphonate and [ 99m Tc]Human serum albumin. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  11. A simple method for validation and verification of pipettes mounted on automated liquid handlers

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Hansen, Anders Johannes; Frøslev, Tobias Guldberg

     We have implemented a simple method for validation and verification of the performance of pipettes mounted on automated liquid handlers as necessary for laboratories accredited under ISO 17025. An 8-step serial dilution of Orange G was prepared in quadruplicates in a flat bottom 96-well microtit...... available. In conclusion, we have set up a simple solution for the continuous validation of automated liquid handlers used for accredited work. The method is cheap, simple and easy to use for aqueous solutions but requires a spectrophotometer that can read microtiter plates....... We have implemented a simple method for validation and verification of the performance of pipettes mounted on automated liquid handlers as necessary for laboratories accredited under ISO 17025. An 8-step serial dilution of Orange G was prepared in quadruplicates in a flat bottom 96-well microtiter...

  12. Validation of a method to measure plutonium levels in marine sediments in Cuba

    International Nuclear Information System (INIS)

    Sibello Hernández, Rita Y.; Cartas Aguila, Héctor A.; Cozzella, María Letizia

    2008-01-01

    The main objective of this research was to develop and to validate a method of radiochemical separation of plutonium, suitable from the economic and practical point of view, in Cuba conditions. This method allowed to determine plutonium activity levels in the marine sediments from Cienfuegos Bay. The selected method of radiochemical separation was that of anionic chromatography and the measure technique was the quadrupole inductively coupled plasma mass spectrometry. The method was applied to a certified reference material, six repetitions were carried out and a good correspondence between the average measured value and the average certified value of plutonium was achieved, so the trueness of the method was demonstrated. It was also proven the precision of the method, since it was obtained a variation coefficient of 11% at 95% confidence level. The obtained results show that the presence of plutonium in the analyzed marine sediment samples is only due to the global radioactive fallout. (author)

  13. Validation of ascorbic acid tablets of national production by igh-performance liquid chromatography method

    International Nuclear Information System (INIS)

    Rodriguez Hernandez, Yaslenis; Suarez Perez, Yania; Izquierdo Castro, Idalberto

    2009-01-01

    We validate an analytical method by high-performance liquid chromatography to determine ascorbic acid proportion in vitamin C tablets, which was designed as an alternative method to quality control and to follow-up of active principle chemical stability, since official techniques to quality control of ascorbic acid in tablets are not selective with degradation products. Method was modified according to that reported in USP 28, 2005 for analysis of injectable product. We used a RP-18 column of 250 x 4.6 mm 5 μm with a UV detector to 245 nm. Its validation was necessary for both objectives, considering parameters required for methods of I and II categories. This method was enough linear, exact, and precise in the rank of 100-300 μg/mL. Also, it was selective with remaining components of matrix and with the possible degradation products achieved in stressing conditions. Detection and quantification limits were estimated. When method was validated it was applied to ascorbic acid quantification in two batches of expired tablets and we detected a marked influence of container in active degradation principle after 12 months at room temperature. (Author)

  14. Inter-laboratory validation of an inexpensive streamlined method to measure inorganic arsenic in rice grain.

    Science.gov (United States)

    Chaney, Rufus L; Green, Carrie E; Lehotay, Steven J

    2018-05-04

    With the establishment by CODEX of a 200 ng/g limit of inorganic arsenic (iAs) in polished rice grain, more analyses of iAs will be necessary to ensure compliance in regulatory and trade applications, to assess quality control in commercial rice production, and to conduct research involving iAs in rice crops. Although analytical methods using high-performance liquid chromatography-inductively coupled plasma-mass spectrometry (HPLC-ICP-MS) have been demonstrated for full speciation of As, this expensive and time-consuming approach is excessive when regulations are based only on iAs. We report a streamlined sample preparation and analysis of iAs in powdered rice based on heated extraction with 0.28 M HNO 3 followed by hydride generation (HG) under control of acidity and other simple conditions. Analysis of iAs is then conducted using flow-injection HG and inexpensive ICP-atomic emission spectroscopy (AES) or other detection means. A key innovation compared with previous methods was to increase the acidity of the reagent solution with 4 M HCl (prior to reduction of As 5+ to As 3+ ), which minimized interferences from dimethylarsinic acid. An inter-laboratory method validation was conducted among 12 laboratories worldwide in the analysis of six shared blind duplicates and a NIST Standard Reference Material involving different types of rice and iAs levels. Also, four laboratories used the standard HPLC-ICP-MS method to analyze the samples. The results between the methods were not significantly different, and the Horwitz ratio averaged 0.52 for the new method, which meets official method validation criteria. Thus, the simpler, more versatile, and less expensive method may be used by laboratories for several purposes to accurately determine iAs in rice grain. Graphical abstract Comparison of iAs results from new and FDA methods.

  15. Validated stability-indicating spectrofluorimetric methods for the determination of ebastine in pharmaceutical preparations

    Directory of Open Access Journals (Sweden)

    Eid Manal

    2011-03-01

    Full Text Available Abstract Two sensitive, selective, economic, and validated spectrofluorimetric methods were developed for the determination of ebastine (EBS in pharmaceutical preparations depending on reaction with its tertiary amino group. Method I involves condensation of the drug with mixed anhydrides (citric and acetic anhydrides producing a product with intense fluorescence, which was measured at 496 nm after excitation at 388 nm. Method (IIA describes quantitative fluorescence quenching of eosin upon addition of the studied drug where the decrease in the fluorescence intensity was directly proportional to the concentration of ebastine; the fluorescence quenching was measured at 553 nm after excitation at 457 nm. This method was extended to (Method IIB to apply first and second derivative synchronous spectrofluorimetric method (FDSFS & SDSFS for the simultaneous analysis of EBS in presence of its alkaline, acidic, and UV degradation products. The proposed methods were successfully applied for the determination of the studied compound in its dosage forms. The results obtained were in good agreement with those obtained by a comparison method. Both methods were utilized to investigate the kinetics of the degradation of the drug.

  16. Validation of a spectrophotometric method to determine ciprofibrate content in tablets

    Directory of Open Access Journals (Sweden)

    Guilherme Nobre Lima do Nascimento

    2011-03-01

    Full Text Available Ciprofibrate is a drug indicated in cases of hypertriglyceridemia and mixed hyperlipidemia, but no monographs are available in official compendia for the analysis of this substance in tablets. The objective of this work was to develop and validate a spectrophotometric method for routine analysis of ciprofibrate in tablets. In this study, commercial and standard ciprofibrate were used, as well as placebo in absolute ethanol, analyzed by UV spectrophotometer. All tests followed the rules of Resolution RE-899, 2003. The results showed that the developed and validated method offers low cost, easy implementation, precision and accuracy, and may be included in the routine of quality control laboratories.O ciprofibrato é um fármaco indicado em casos de hipertrigliceridemia e hiperlipidemia mista, mas não há monografias em compêndios oficiais para a análise desta substância em comprimidos. O objetivo deste trabalho é desenvolver e validar um método espectrofotométrico para análise de rotina de ciprofibrato em comprimidos. Neste estudo foram empregados ciprofibrato comercial, padrão e placebo em etanol absoluto, analisadas por espectrofotometria UV. Todos os testes seguiram as regras da Resolução RE- 899, 2003. Os resultados mostraram que o método desenvolvido e validado apresenta baixo custo, fácil implementação, precisão e exatidão e pode ser incluído em rotina de laboratórios de controle de qualidade.

  17. VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A.

    2008-12-17

    This document proposes to provide a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers, and books reviewed is given in Appendix 1. Available validation documents and guides are listed in the appendix; each has a brief description of application and use. In the referenced sources, there are varying approaches to validation and varying descriptions of validation at different stages in method development. This discussion focuses on validation and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all documents were published in English.

  18. GC Method Validation for the Analysis of Menthol in Suppository Pharmaceutical Dosage Form

    Directory of Open Access Journals (Sweden)

    Murad N. Abualhasan

    2017-01-01

    Full Text Available Menthol is widely used as a fragrance and flavor in the food and cosmetic industries. It is also used in the medical and pharmaceutical fields for its various biological effects. Gas chromatography (GC is considered to be a sensitive method for the analysis of menthol. GC chromatographic separation was developed using capillary column (VF-624 and a flame ionization detector (FID. The method was validated as per ICH guidelines for various parameters such as precision, linearity, accuracy, solution stability, robustness, limit of detection, and quantification. The tested validation parameters were found to be within acceptable limits. The method was successfully applied for the quantification of menthol in suppositories formulations. Quality control departments and official pharmacopeias can use our developed method in the analysis of menthol in pharmaceutical dosage formulation and raw material.

  19. A collaborative design method to support integrated care. An ICT development method containing continuous user validation improves the entire care process and the individual work situation

    Science.gov (United States)

    Scandurra, Isabella; Hägglund, Maria

    2009-01-01

    Introduction Integrated care involves different professionals, belonging to different care provider organizations and requires immediate and ubiquitous access to patient-oriented information, supporting an integrated view on the care process [1]. Purpose To present a method for development of usable and work process-oriented information and communication technology (ICT) systems for integrated care. Theory and method Based on Human-computer Interaction Science and in particular Participatory Design [2], we present a new collaborative design method in the context of health information systems (HIS) development [3]. This method implies a thorough analysis of the entire interdisciplinary cooperative work and a transformation of the results into technical specifications, via user validated scenarios, prototypes and use cases, ultimately leading to the development of appropriate ICT for the variety of occurring work situations for different user groups, or professions, in integrated care. Results and conclusions Application of the method in homecare of the elderly resulted in an HIS that was well adapted to the intended user groups. Conducted in multi-disciplinary seminars, the method captured and validated user needs and system requirements for different professionals, work situations, and environments not only for current work; it also aimed to improve collaboration in future (ICT supported) work processes. A holistic view of the entire care process was obtained and supported through different views of the HIS for different user groups, resulting in improved work in the entire care process as well as for each collaborating profession [4].

  20. Validation of Likelihood Ratio Methods Used for Forensic Evidence Evaluation: Application in Forensic Fingerprints

    NARCIS (Netherlands)

    Haraksim, Rudolf

    2014-01-01

    In this chapter the Likelihood Ratio (LR) inference model will be introduced, the theoretical aspects of probabilities will be discussed and the validation framework for LR methods used for forensic evidence evaluation will be presented. Prior to introducing the validation framework, following

  1. Validation of the Analytical Method for the Determination of Flavonoids in Broccoli

    Directory of Open Access Journals (Sweden)

    Tuszyńska Magdalena

    2014-09-01

    Full Text Available A simple, accurate and selective HPLC method was developed and validated for determination of quercetin and kaempferol, which are the main flavonols in broccoli. The separation was achieved on a reversed-phase C18 column using a mobile phase composed of methanol/water (60/40 and phosphoric acid 0.2% at a flow rate of 1.0 ml min-1. The detection was carried out on a DAD detector at 370 nm. This method was validated according to the requirements for new methods, which include selectivity, linearity, precision, accuracy, limit of detection and limit of quantitation. The current method demonstrates good linearity, with R2 > 0.99. The recovery is within 98.07-102.15% and 97.92-101.83% for quercetin and kaempferol, respectively. The method is selective, in that quercetin and kaempferol are well separated from other compounds of broccoli with good resolution. The low limit of detection and limit of quantitation of quercetin and kaempferol enable the detection and quantitation of these flavonoids in broccoli at low con–centrations.

  2. Validated spectophotometric methods for the assay of cinitapride hydrogen tartrate in pharmaceuticals

    Directory of Open Access Journals (Sweden)

    Satyanarayana K.V.V.

    2013-01-01

    Full Text Available Three simple, selective and rapid spectrophotometric methods have been established for the determination of cinitapride hydrogen tartrate (CHT in pharmaceutical tablets. The proposed methods are based on the diazotization of CHT with sodium nitrite and hydrochloric acid, followed by coupling with resorcinol, 1-benzoylacetone and 8-hydroxyquinoline in alkaline medium for methods A, B and C respectively. The formed azo dyes are measured at 442, 465 and 552 nm for methods A, B and C respectively. The parameters that affect the reaction were carefully optimized. Under optimum conditions, Beer’s law is obeyed over the ranges 2.0-32.0, 1.0-24.0 and 1.0-20.0 μg. mL-1 for methods A, B, and C, respectively. The calculated molar absorptivity values are 1.2853 x104, 1.9624 x104 and 3.92 x104 L.mol-1.cm-1 for methods A, B and C, respectively. The results of the proposed procedures were validated statistically according to ICH guidelines. The proposed methods were successfully applied to the determination of CHT in Cintapro tablets without interference from common excipients encountered.

  3. Determination of calcium, magnesium, sodium, and potassium in foodstuffs by using a microsampling flame atomic absorption spectrometric method after closed-vessel microwave digestion: method validation.

    Science.gov (United States)

    Chekri, Rachida; Noël, Laurent; Vastel, Christelle; Millour, Sandrine; Kadar, Ali; Guérin, Thierry

    2010-01-01

    This paper describes a validation process in compliance with the NFIEN ISO/IEC 17025 standard for the determination of the macrominerals calcium, magnesium, sodium, and potassium in foodstuffs by microsampling with flame atomic absorption spectrometry after closed-vessel microwave digestion. The French Standards Commission (Agence Francaise de Normalisation) standards NF V03-110, NF EN V03-115, and XP T-90-210 were used to evaluate this method. The method was validated in the context of an analysis of the 1322 food samples of the second French Total Diet Study (TDS). Several performance criteria (linearity, LOQ, specificity, trueness, precision under repeatability conditions, and intermediate precision reproducibility) were evaluated. Furthermore, the method was monitored by several internal quality controls. The LOQ values obtained (25, 5, 8.3, and 8.3 mg/kg for Ca, Mg, Na, and K, respectively) were in compliance with the needs of the TDS. The method provided accurate results as demonstrated by a repeatability CV (CVr) of < 7% and a reproducibility CV (CVR) of < 12% for all the elements. Therefore, the results indicated that this method could be used in the laboratory for the routine determination of these four elements in foodstuffs with acceptable analytical performance.

  4. NordVal: A Nordic system for validation of alternative microbiological methods

    DEFF Research Database (Denmark)

    Qvist, Sven

    2007-01-01

    NordVal was created in 1999 by the Nordic Committee of Senior Officials for Food Issues under the Nordic Council of Ministers. The Committee adopted the following objective for NordVal: NordVal evaluates the performance and field of application of alternative microbiological methods. This includes...... analyses of food, water, feed, animal faeces and food environmental samples in the Nordic countries. NordVal is managed by a steering group, which is appointed by the National Food Administrations in Denmark, Finland, Iceland, Norway and Sweden. The background for creation of NordVal was a Danish...... validation system (DanVal) established in 1995 to cope with a need to validate alternative methods to be used in the Danish Salmonella Action Program. The program attracted considerable attention in the other Nordic countries. NordVal has elaborated a number of documents, which describe the requirements...

  5. Validation needs of seismic probabilistic risk assessment (PRA) methods applied to nuclear power plants

    International Nuclear Information System (INIS)

    Kot, C.A.; Srinivasan, M.G.; Hsieh, B.J.

    1985-01-01

    An effort to validate seismic PRA methods is in progress. The work concentrates on the validation of plant response and fragility estimates through the use of test data and information from actual earthquake experience. Validation needs have been identified in the areas of soil-structure interaction, structural response and capacity, and equipment fragility. Of particular concern is the adequacy of linear methodology to predict nonlinear behavior. While many questions can be resolved through the judicious use of dynamic test data, other aspects can only be validated by means of input and response measurements during actual earthquakes. A number of past, ongoing, and planned testing programs which can provide useful validation data have been identified, and validation approaches for specific problems are being formulated

  6. Implementation of the 3Rs (refinement, reduction, and replacement): validation and regulatory acceptance considerations for alternative toxicological test methods.

    Science.gov (United States)

    Schechtman, Leonard M

    2002-01-01

    Toxicological testing in the current regulatory environment is steeped in a history of using animals to answer questions about the safety of products to which humans are exposed. That history forms the basis for the testing strategies that have evolved to satisfy the needs of the regulatory bodies that render decisions that affect, for the most part, virtually all phases of premarket product development and evaluation and, to a lesser extent, postmarketing surveillance. Only relatively recently have the levels of awareness of, and responsiveness to, animal welfare issues reached current proportions. That paradigm shift, although sluggish, has nevertheless been progressive. New and alternative toxicological methods for hazard evaluation and risk assessment have now been adopted and are being viewed as a means to address those issues in a manner that considers humane treatment of animals yet maintains scientific credibility and preserves the goal of ensuring human safety. To facilitate this transition, regulatory agencies and regulated industry must work together toward improved approaches. They will need assurance that the methods will be reliable and the results comparable with, or better than, those derived from the current classical methods. That confidence will be a function of the scientific validation and resultant acceptance of any given method. In the United States, to fulfill this need, the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM) and its operational center, the National Toxicology Program Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM), have been constituted as prescribed in federal law. Under this mandate, ICCVAM has developed a process and established criteria for the scientific validation and regulatory acceptance of new and alternative methods. The role of ICCVAM in the validation and acceptance process and the criteria instituted toward that end are described. Also

  7. Validation of the Use of Dried Blood Spot (DBS) Method to Assess Vitamin A Status

    Science.gov (United States)

    Fallah, Elham; Peighambardoust, Seyed Hadi

    2012-01-01

    Background: Vitamin A deficiency is an important dietary deficiency in the world. Thus, the ne¬cessity of screening for deficient populations is obvious. This paper introduces a fast, cheap and relatively reliable method called “dried blood spot” (DBS) method in screening the deficient populations. The validity of this method for retinol measurement was investigated. Method: The “precision” and “agreement” criteria of the DBS method were assessed. The preci¬sion was calculated and compared with those of plasma using F-test. The agreement was eva¬luated using Bland-Altman plot. Results: The imprecision of retinol measurements in dried spots was not significantly different from those of the control (plasma). A good correlation coefficient (r2=0.78) was obtained for dried spots’ retinol measurements versus plasma’s retinol analysis (P dried spots was stable for 90 days. Overall, the DBS method provided a precise measurement of retinol, showing results that were comparable with the measurement of retinol in plasma. PMID:24688932

  8. Validation for Vegetation Green-up Date Extracted from GIMMS NDVI and NDVI3g Using Variety of Methods

    Science.gov (United States)

    Chang, Q.; Jiao, W.

    2017-12-01

    Phenology is a sensitive and critical feature of vegetation change that has regarded as a good indicator in climate change studies. So far, variety of remote sensing data sources and phenology extraction methods from satellite datasets have been developed to study the spatial-temporal dynamics of vegetation phenology. However, the differences between vegetation phenology results caused by the varies satellite datasets and phenology extraction methods are not clear, and the reliability for different phenology results extracted from remote sensing datasets is not verified and compared using the ground observation data. Based on three most popular remote sensing phenology extraction methods, this research calculated the Start of the growing season (SOS) for each pixels in the Northern Hemisphere for two kinds of long time series satellite datasets: GIMMS NDVIg (SOSg) and GIMMS NDVI3g (SOS3g). The three methods used in this research are: maximum increase method, dynamic threshold method and midpoint method. Then, this study used SOS calculated from NEE datasets (SOS_NEE) monitored by 48 eddy flux tower sites in global flux website to validate the reliability of six phenology results calculated from remote sensing datasets. Results showed that both SOSg and SOS3g extracted by maximum increase method are not correlated with ground observed phenology metrics. SOSg and SOS3g extracted by the dynamic threshold method and midpoint method are both correlated with SOS_NEE significantly. Compared with SOSg extracted by the dynamic threshold method, SOSg extracted by the midpoint method have a stronger correlation with SOS_NEE. And, the same to SOS3g. Additionally, SOSg showed stronger correlation with SOS_NEE than SOS3g extracted by the same method. SOS extracted by the midpoint method from GIMMS NDVIg datasets seemed to be the most reliable results when validated with SOS_NEE. These results can be used as reference for data and method selection in future's phenology study.

  9. Development and validation of a stability indicating HPTLC-densitometric method for lafutidine

    Directory of Open Access Journals (Sweden)

    Dinesh Dhamecha

    2013-01-01

    Full Text Available Background: A simple, selective, precise, and stability indicating high-performance thin layer chromatographic method has been established and validated for analysis of lafutidine in bulk drug and formulations. Materials and Methods: The compounds were analyzed on aluminum backed silica gel 60 F 254 plates with chloroform:ethanol:acetic Acid (8:1:1 as mobile phase. Densitometric analysis of lafutidine was performed at 230 nm. Result : Regression analysis data for the calibration plots were indicative of good linear relationship between response and concentration over the range 100-500 ng per spot. The correlation coefficient (r 2 was 0.998±0.002. Conclusion: Lafutidine was subjected to acid, base, peroxide, and sunlight degradation. In stability tests, the drug was susceptible to acid and basic hydrolysis, oxidation, and photodegradation.

  10. Oxcarbazepine: validation and application of an analytical method

    Directory of Open Access Journals (Sweden)

    Paula Cristina Rezende Enéas

    2010-06-01

    Full Text Available Oxcarbazepine (OXC is an important anticonvulsant and mood stabilizing drug. A pharmacopoeial monograph for OXC is not yet available and therefore the development and validation of a new analytical method for quantification of this drug is essential. In the present study, a UV spectrophotometric method for the determination of OXC was developed. The various parameters, such as linearity, precision, accuracy and specificity, were studied according to International Conference on Harmonization Guidelines. Batches of 150 mg OXC capsules were prepared and analyzed using the validated UV method. The formulations were also evaluated for parameters including drug-excipient compatibility, flowability, uniformity of weight, disintegration time, assay, uniformity of content and the amount of drug dissolved during the first hour.Oxcarbazepina (OXC é um fármaco anticonvulsivante e estabilizante do humor. O desenvolvimento e validação de método analítico para quantificação da OXC são de fundamental importância devido à ausência de monografias farmacopéicas oficiais para esse fármaco. Nesse trabalho, um método espectrofotométrico UV para determinação da OXC foi desenvolvido. O método proposto foi validado seguindo os parâmetros de linearidade, precisão, exatidão e especificidade de acordo com as normas da Conferência Internacional de Harmonização. Cápsulas de OXC 150 mg foram preparadas e analisadas utilizando-se o método analítico validado. As formulações foram avaliadas com relação à compatibilidade fármaco-excipientes, fluidez, determinação de peso, tempo de desintegração, doseamento, uniformidade de conteúdo e quantidade do fármaco dissolvido após 60 minutos.

  11. A Validated Stability-Indicating HPLC Method for Simultaneous Determination of Amoxicillin and Enrofloxacin Combination in an Injectable Suspension

    Directory of Open Access Journals (Sweden)

    Nidal Batrawi

    2017-02-01

    Full Text Available The combination of amoxicillin and enrofloxacin is a well-known mixture of veterinary drugs; it is used for the treatment of Gram-positive and Gram-negative bacteria. In the scientific literature, there is no high-performance liquid chromatography (HPLC-UV method for the simultaneous determination of this combination. The objective of this work is to develop and validate an HPLC method for the determination of this combination. In this regard, a new, simple and efficient reversed-phase HPLC method for simultaneous qualitative and quantitative determination of amoxicillin and enrofloxacin, in an injectable preparation with a mixture of inactive excipients, has been developed and validated. The HPLC separation method was performed using a reversed-phase (RP-C18e (250 mm × 4.0 mm, 5 μm column at room temperature, with a gradient mobile phase of acetonitrile and phosphate buffer containing methanol at pH 5.0, a flow rate of 0.8 mL/min and ultraviolet detection at 267 nm. This method was validated in accordance with the Food and Drug Administration (FDA and the International Conference on Harmonisation (ICH guidelines and showed excellent linearity, accuracy, precision, specificity, robustness, ruggedness, and system suitability results within the acceptance criteria. A stability-indicating study was also carried out and indicated that this method can also be used for purity and degradation evaluation of these formulations.

  12. Simulation Methods and Validation Criteria for Modeling Cardiac Ventricular Electrophysiology.

    Directory of Open Access Journals (Sweden)

    Shankarjee Krishnamoorthi

    Full Text Available We describe a sequence of methods to produce a partial differential equation model of the electrical activation of the ventricles. In our framework, we incorporate the anatomy and cardiac microstructure obtained from magnetic resonance imaging and diffusion tensor imaging of a New Zealand White rabbit, the Purkinje structure and the Purkinje-muscle junctions, and an electrophysiologically accurate model of the ventricular myocytes and tissue, which includes transmural and apex-to-base gradients of action potential characteristics. We solve the electrophysiology governing equations using the finite element method and compute both a 6-lead precordial electrocardiogram (ECG and the activation wavefronts over time. We are particularly concerned with the validation of the various methods used in our model and, in this regard, propose a series of validation criteria that we consider essential. These include producing a physiologically accurate ECG, a correct ventricular activation sequence, and the inducibility of ventricular fibrillation. Among other components, we conclude that a Purkinje geometry with a high density of Purkinje muscle junctions covering the right and left ventricular endocardial surfaces as well as transmural and apex-to-base gradients in action potential characteristics are necessary to produce ECGs and time activation plots that agree with physiological observations.

  13. Simulation Methods and Validation Criteria for Modeling Cardiac Ventricular Electrophysiology.

    Science.gov (United States)

    Krishnamoorthi, Shankarjee; Perotti, Luigi E; Borgstrom, Nils P; Ajijola, Olujimi A; Frid, Anna; Ponnaluri, Aditya V; Weiss, James N; Qu, Zhilin; Klug, William S; Ennis, Daniel B; Garfinkel, Alan

    2014-01-01

    We describe a sequence of methods to produce a partial differential equation model of the electrical activation of the ventricles. In our framework, we incorporate the anatomy and cardiac microstructure obtained from magnetic resonance imaging and diffusion tensor imaging of a New Zealand White rabbit, the Purkinje structure and the Purkinje-muscle junctions, and an electrophysiologically accurate model of the ventricular myocytes and tissue, which includes transmural and apex-to-base gradients of action potential characteristics. We solve the electrophysiology governing equations using the finite element method and compute both a 6-lead precordial electrocardiogram (ECG) and the activation wavefronts over time. We are particularly concerned with the validation of the various methods used in our model and, in this regard, propose a series of validation criteria that we consider essential. These include producing a physiologically accurate ECG, a correct ventricular activation sequence, and the inducibility of ventricular fibrillation. Among other components, we conclude that a Purkinje geometry with a high density of Purkinje muscle junctions covering the right and left ventricular endocardial surfaces as well as transmural and apex-to-base gradients in action potential characteristics are necessary to produce ECGs and time activation plots that agree with physiological observations.

  14. Method for appraising model validity of randomised controlled trials of homeopathic treatment: multi-rater concordance study

    Science.gov (United States)

    2012-01-01

    Background A method for assessing the model validity of randomised controlled trials of homeopathy is needed. To date, only conventional standards for assessing intrinsic bias (internal validity) of trials have been invoked, with little recognition of the special characteristics of homeopathy. We aimed to identify relevant judgmental domains to use in assessing the model validity of homeopathic treatment (MVHT). We define MVHT as the extent to which a homeopathic intervention and the main measure of its outcome, as implemented in a randomised controlled trial (RCT), reflect 'state-of-the-art' homeopathic practice. Methods Using an iterative process, an international group of experts developed a set of six judgmental domains, with associated descriptive criteria. The domains address: (I) the rationale for the choice of the particular homeopathic intervention; (II) the homeopathic principles reflected in the intervention; (III) the extent of homeopathic practitioner input; (IV) the nature of the main outcome measure; (V) the capability of the main outcome measure to detect change; (VI) the length of follow-up to the endpoint of the study. Six papers reporting RCTs of homeopathy of varying design were randomly selected from the literature. A standard form was used to record each assessor's independent response per domain, using the optional verdicts 'Yes', 'Unclear', 'No'. Concordance among the eight verdicts per domain, across all six papers, was evaluated using the kappa (κ) statistic. Results The six judgmental domains enabled MVHT to be assessed with 'fair' to 'almost perfect' concordance in each case. For the six RCTs examined, the method allowed MVHT to be classified overall as 'acceptable' in three, 'unclear' in two, and 'inadequate' in one. Conclusion Future systematic reviews of RCTs in homeopathy should adopt the MVHT method as part of a complete appraisal of trial validity. PMID:22510227

  15. Validation study of core analysis methods for full MOX BWR

    International Nuclear Information System (INIS)

    2013-01-01

    JNES has been developing a technical database used in reviewing validation of core analysis methods of LWRs in the coming occasions: (1) confirming the core safety parameters of the initial core (one-third MOX core) through a full MOX core in Oma Nuclear Power Plant, which is under the construction, (2) licensing high-burnup MOX cores in the future and (3) reviewing topical reports on core analysis codes for safety design and evaluation. Based on the technical database, JNES will issue a guide of reviewing the core analysis methods used for safety design and evaluation of LWRs. The database will be also used for validation and improving of core analysis codes developed by JNES. JNES has progressed with the projects: (1) improving a Doppler reactivity analysis model in a Monte Carlo calculation code MVP, (2) sensitivity study of nuclear cross section date on reactivity calculation of experimental cores composed of UO 2 and MOX fuel rods, (3) analysis of isotopic composition data for UO 2 and MOX fuels and (4) the guide of reviewing the core analysis codes and others. (author)

  16. Validation study of core analysis methods for full MOX BWR

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    JNES has been developing a technical database used in reviewing validation of core analysis methods of LWRs in the coming occasions: (1) confirming the core safety parameters of the initial core (one-third MOX core) through a full MOX core in Oma Nuclear Power Plant, which is under the construction, (2) licensing high-burnup MOX cores in the future and (3) reviewing topical reports on core analysis codes for safety design and evaluation. Based on the technical database, JNES will issue a guide of reviewing the core analysis methods used for safety design and evaluation of LWRs. The database will be also used for validation and improving of core analysis codes developed by JNES. JNES has progressed with the projects: (1) improving a Doppler reactivity analysis model in a Monte Carlo calculation code MVP, (2) sensitivity study of nuclear cross section date on reactivity calculation of experimental cores composed of UO{sub 2} and MOX fuel rods, (3) analysis of isotopic composition data for UO{sub 2} and MOX fuels and (4) the guide of reviewing the core analysis codes and others. (author)

  17. Optimisation and validation of methods to assess single nucleotide polymorphisms (SNPs) in archival histological material

    DEFF Research Database (Denmark)

    Andreassen, C N; Sørensen, Flemming Brandt; Overgaard

    2004-01-01

    only archival specimens are available. This study was conducted to validate protocols optimised for assessment of SNPs based on paraffin embedded, formalin fixed tissue samples.PATIENTS AND METHODS: In 137 breast cancer patients, three TGFB1 SNPs were assessed based on archival histological specimens...... precipitation).RESULTS: Assessment of SNPs based on archival histological material is encumbered by a number of obstacles and pitfalls. However, these can be widely overcome by careful optimisation of the methods used for sample selection, DNA extraction and PCR. Within 130 samples that fulfil the criteria...

  18. Applying the Mixed Methods Instrument Development and Construct Validation Process: the Transformative Experience Questionnaire

    Science.gov (United States)

    Koskey, Kristin L. K.; Sondergeld, Toni A.; Stewart, Victoria C.; Pugh, Kevin J.

    2018-01-01

    Onwuegbuzie and colleagues proposed the Instrument Development and Construct Validation (IDCV) process as a mixed methods framework for creating and validating measures. Examples applying IDCV are lacking. We provide an illustrative case integrating the Rasch model and cognitive interviews applied to the development of the Transformative…

  19. The Mistra experiment for field containment code validation first results

    International Nuclear Information System (INIS)

    Caron-Charles, M.; Blumenfeld, L.

    2001-01-01

    The MISTRA facility is a large scale experiment, designed for the purpose of thermal-hydraulics multi-D codes validation. A short description of the facility, the set up of the instrumentation and the test program are presented. Then, the first experimental results, studying helium injection in the containment and their calculations are detailed. (author)

  20. Statistical methods for mechanistic model validation: Salt Repository Project

    International Nuclear Information System (INIS)

    Eggett, D.L.

    1988-07-01

    As part of the Department of Energy's Salt Repository Program, Pacific Northwest Laboratory (PNL) is studying the emplacement of nuclear waste containers in a salt repository. One objective of the SRP program is to develop an overall waste package component model which adequately describes such phenomena as container corrosion, waste form leaching, spent fuel degradation, etc., which are possible in the salt repository environment. The form of this model will be proposed, based on scientific principles and relevant salt repository conditions with supporting data. The model will be used to predict the future characteristics of the near field environment. This involves several different submodels such as the amount of time it takes a brine solution to contact a canister in the repository, how long it takes a canister to corrode and expose its contents to the brine, the leach rate of the contents of the canister, etc. These submodels are often tested in a laboratory and should be statistically validated (in this context, validate means to demonstrate that the model adequately describes the data) before they can be incorporated into the waste package component model. This report describes statistical methods for validating these models. 13 refs., 1 fig., 3 tabs

  1. VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

    Energy Technology Data Exchange (ETDEWEB)

    Ekechukwu, A

    2009-05-27

    Method validation is the process of evaluating whether an analytical method is acceptable for its intended purpose. For pharmaceutical methods, guidelines from the United States Pharmacopeia (USP), International Conference on Harmonisation (ICH), and the United States Food and Drug Administration (USFDA) provide a framework for performing such valications. In general, methods for regulatory compliance must include studies on specificity, linearity, accuracy, precision, range, detection limit, quantitation limit, and robustness. Elements of these guidelines are readily adapted to the issue of validation for beryllium sampling and analysis. This document provides a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers and books reviewed is given in the Appendix. Available validation documents and guides are listed therein; each has a brief description of application and use. In the referenced sources, there are varying approches to validation and varying descriptions of the valication process at different stages in method development. This discussion focuses on valication and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all referenced documents were published in English.

  2. Development and Validation of a Stability-Indicating LC-UV Method ...

    African Journals Online (AJOL)

    Development and Validation of a Stability-Indicating LC-UV Method for Simultaneous Determination of Ketotifen and Cetirizine in Pharmaceutical Dosage Forms. ... 5 μm) using an isocratic mobile phase that consisted of acetonitrile and 10 mM disodium hydrogen phosphate buffer (pH 6.5) in a ratio of 45:55 % v/v at a flow ...

  3. Comparison of the performances and validation of three methods for ...

    African Journals Online (AJOL)

    SARAH

    2014-02-28

    Feb 28, 2014 ... bacteria in Norwegian slaughter pigs. Int J. Food Microbiol 1, 301–309. [NCFA] Nordic Committee of Food Analysis (1996). Yersinia enterocolitica Detection in foods 117,. 3rd,edn,1-12. Nowak, B., Mueffling, T.V., Caspari, K. and Hartung, J. 2006 Validation of a method for the detection of virulent Yersinia ...

  4. Quality of life and hormone use: new validation results of MRS scale

    Directory of Open Access Journals (Sweden)

    Heinemann Lothar AJ

    2006-05-01

    Full Text Available Abstract Background The Menopause Rating Scale is a health-related Quality of Life scale developed in the early 1990s and step-by-step validated since then. Recently the MRS scale was validated as outcomes measure for hormone therapy. The suspicion however was expressed that the data were too optimistic due to methodological problems of the study. A new study became available to check how founded this suspicion was. Method An open post-marketing study of 3282 women with pre- and post- treatment data of the self-administered version of the MRS scale was analyzed to evaluate the capacity of the scale to detect hormone treatment related effects with the MRS scale. The main results were then compared with the old study where the interview-based version of the MRS scale was used. Results The hormone-therapy related improvement of complaints relative to the baseline score was about or less than 30% in total or domain scores, whereas it exceeded 30% improvement in the old study. Similarly, the relative improvement after therapy, stratified by the degree of severity at baseline, was lower in the new than in the old study, but had the same slope. Although we cannot exclude different treatment effects with the study method used, this supports our hypothesis that the individual MRS interviews performed by the physician biased the results towards over-estimation of the treatment effects. This hypothesis is underlined by the degree of concordance of physician's assessment and patient's perception of treatment success (MRS results: Sensitivity (correct prediction of the positive assessment by the treating physician of the MRS and specificity (correct prediction of a negative assessment by the physician were lower than the results obtained with the interview-based MRS scale in the previous publication. Conclusion The study confirmed evidence for the capacity of the MRS scale to measure treatment effects on quality of life across the full range of severity of

  5. Validation of Cyanoacrylate Method for Collection of Stratum Corneum in Human Skin for Lipid Analysis

    DEFF Research Database (Denmark)

    Jungersted, JM; Hellgren, Lars; Drachmann, Tue

    2010-01-01

    Background and Objective: Lipids in the stratum corneum (SC) are of major importance for the skin barrier function. Many different methods have been used for the collection of SC for the analysis of SC lipids. The objective of the present study was to validate the cyanoacrylate method for the col......Background and Objective: Lipids in the stratum corneum (SC) are of major importance for the skin barrier function. Many different methods have been used for the collection of SC for the analysis of SC lipids. The objective of the present study was to validate the cyanoacrylate method...

  6. Validation of an HPLC–UV method for the determination of digoxin residues on the surface of manufacturing equipment

    Directory of Open Access Journals (Sweden)

    ZORAN B. TODOROVIĆ

    2009-09-01

    Full Text Available In the pharmaceutical industry, an important step consists in the removal of possible drug residues from the involved equipments and areas. The cleaning procedures must be validated and methods to determine trace amounts of drugs have, therefore, to be considered with special attention. An HPLC–UV method for the determination of digoxin residues on stainless steel surfaces was developed and validated in order to control a cleaning procedure. Cotton swabs, moistened with methanol were used to remove any residues of drugs from stainless steel surfaces, and give recoveries of 85.9, 85.2 and 78.7 % for three concentration levels. The precision of the results, reported as the relative standard deviation (RSD, were below 6.3 %. The method was validated over a concentration range of 0.05–12.5 µg mL-1. Low quantities of drug residues were determined by HPLC–UV using a Symmetry C18 column (150´4.6 mm, 5 µm at 20 °C with an acetonitrile–water (28:72, v/v mobile phase at a flow rate of 1.1 mL min-1, an injection volume of 100 µL and were detected at 220 nm. A simple, selective and sensitive HPLC–UV assay for the determination of digoxin residues on stainless steel was developed, validated and applied.

  7. Contribution to the validation of thermal ratchetting prevision methods in metallic structures

    International Nuclear Information System (INIS)

    Rakotovelo, A.M.

    1998-03-01

    This work concerns the steady state assessment in the metallic structures subjected to thermomechanical cyclic loadings in biaxial stress state. The effect of the short time mechanical overloads is also investigated. The first chapter is devoted to a bibliographic research concerning the behaviour of the materials and the structures in the cyclic plasticity. Some works relate to the experimental aspect as well as the numerical one for the steady state assessment of such structures are presented. The experimental part of the study is presented in the second chapter. The experimental device was carried out in order to prescribe tension and torsion forces combined with cyclic thermal loading. Some tests was then carried out, among these tests certain include some overloads in tension or torsion. The last chapter describes the numerical calculations using different models (linear isotropic hardening, linear kinematic hardening and elasto-viscoplastic Chaboche's model) and the application of some simplified methods for the ratchetting assessment in the structures. We have considered two categories of methods. The first one is based on an elastic analysis (Bree's diagram, 3 Sm rule, efficiency rule) and the second one combines elastic analysis and elastoplastic analysis of the first cycle (Gatt's and Taleb's methods). The results of this study have enabled: to validate in the biaxial stress state an expression which takes into account the effect of mechanical short time overloads; to test the performances of considered models to describe the evolution of the structure during the first cycle and to take into account the effect of short time overloads. Among the considered models, the elastoplastic Chaboche's model seems to be the most accurate to describe the structure's behaviour during the first cycles; to validate some simplified methods. Certain methods based only on elastic analysis (Bee's diagram and efficiency rule) seem not suitable for the considered kind of

  8. Experimental Results and Numerical Simulation of the Target RCS using Gaussian Beam Summation Method

    Directory of Open Access Journals (Sweden)

    Ghanmi Helmi

    2018-05-01

    Full Text Available This paper presents a numerical and experimental study of Radar Cross Section (RCS of radar targets using Gaussian Beam Summation (GBS method. The purpose GBS method has several advantages over ray method, mainly on the caustic problem. To evaluate the performance of the chosen method, we started the analysis of the RCS using Gaussian Beam Summation (GBS and Gaussian Beam Launching (GBL, the asymptotic models Physical Optic (PO, Geometrical Theory of Diffraction (GTD and the rigorous Method of Moment (MoM. Then, we showed the experimental validation of the numerical results using experimental measurements which have been executed in the anechoic chamber of Lab-STICC at ENSTA Bretagne. The numerical and experimental results of the RCS are studied and given as a function of various parameters: polarization type, target size, Gaussian beams number and Gaussian beams width.

  9. Stepwise Procedure for Development and Validation of a Multipesticide Method

    Energy Technology Data Exchange (ETDEWEB)

    Ambrus, A. [Hungarian Food Safety Office, Budapest (Hungary)

    2009-07-15

    The stepwise procedure for development and the validation of so called multi-pesticide methods are described. Principles, preliminary actions, criteria for the selection of chromatographic separation, detection and performance verification of multi-pesticide methods are outlined. Also the long term repeatability and reproducibility, as well as the necessity for the documentation of laboratory work are highlighted. Appendix I hereof describes in detail the calculation of calibration parameters, whereas Appendix II focuses on the calculation of the significance of differences of concentrations obtained on two different separation columns. (author)

  10. Analytical method for the identification and assay of 12 phthalates in cosmetic products: application of the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques".

    Science.gov (United States)

    Gimeno, Pascal; Maggio, Annie-Françoise; Bousquet, Claudine; Quoirez, Audrey; Civade, Corinne; Bonnet, Pierre-Antoine

    2012-08-31

    Esters of phthalic acid, more commonly named phthalates, may be present in cosmetic products as ingredients or contaminants. Their presence as contaminant can be due to the manufacturing process, to raw materials used or to the migration of phthalates from packaging when plastic (polyvinyl chloride--PVC) is used. 8 phthalates (DBP, DEHP, BBP, DMEP, DnPP, DiPP, DPP, and DiBP), classified H360 or H361, are forbidden in cosmetics according to the European regulation on cosmetics 1223/2009. A GC/MS method was developed for the assay of 12 phthalates in cosmetics, including the 8 phthalates regulated. Analyses are carried out on a GC/MS system with electron impact ionization mode (EI). The separation of phthalates is obtained on a cross-linked 5%-phenyl/95%-dimethylpolysiloxane capillary column 30 m × 0.25 mm (i.d.) × 0.25 mm film thickness using a temperature gradient. Phthalate quantification is performed by external calibration using an internal standard. Validation elements obtained on standard solutions, highlight a satisfactory system conformity (resolution>1.5), a common quantification limit at 0.25 ng injected, an acceptable linearity between 0.5 μg mL⁻¹ and 5.0 μg mL⁻¹ as well as a precision and an accuracy in agreement with in-house specifications. Cosmetic samples ready for analytical injection are analyzed after a dilution in ethanol whereas more complex cosmetic matrices, like milks and creams, are assayed after a liquid/liquid extraction using ter-butyl methyl ether (TBME). Depending on the type of cosmetics analyzed, the common limits of quantification for the 12 phthalates were set at 0.5 or 2.5 μg g⁻¹. All samples were assayed using the analytical approach described in the ISO 12787 international standard "Cosmetics-Analytical methods-Validation criteria for analytical results using chromatographic techniques". This analytical protocol is particularly adapted when it is not possible to make reconstituted sample matrices. Copyright © 2012

  11. Validation of newly developed and redesigned key indicator methods for assessment of different working conditions with physical workloads based on mixed-methods design: a study protocol.

    Science.gov (United States)

    Klussmann, Andre; Liebers, Falk; Brandstädt, Felix; Schust, Marianne; Serafin, Patrick; Schäfer, Andreas; Gebhardt, Hansjürgen; Hartmann, Bernd; Steinberg, Ulf

    2017-08-21

    The impact of work-related musculoskeletal disorders is considerable. The assessment of work tasks with physical workloads is crucial to estimate the work-related health risks of exposed employees. Three key indicator methods are available for risk assessment regarding manual lifting, holding and carrying of loads; manual pulling and pushing of loads; and manual handling operations. Three further KIMs for risk assessment regarding whole-body forces, awkward body postures and body movement have been developed de novo. In addition, the development of a newly drafted combined method for mixed exposures is planned. All methods will be validated regarding face validity, reliability, convergent validity, criterion validity and further aspects of utility under practical conditions. As part of the joint project MEGAPHYS (multilevel risk assessment of physical workloads), a mixed-methods study is being designed for the validation of KIMs and conducted in companies of different sizes and branches in Germany. Workplaces are documented and analysed by observations, applying KIMs, interviews and assessment of environmental conditions. Furthermore, a survey among the employees at the respective workplaces takes place with standardised questionnaires, interviews and physical examinations. It is intended to include 1200 employees at 120 different workplaces. For analysis of the quality criteria, recommendations of the COSMIN checklist (COnsensus-based Standards for the selection of health Measurement INstruments) will be taken into account. The study was planned and conducted in accordance with the German Medical Professional Code and the Declaration of Helsinki as well as the German Federal Data Protection Act. The design of the study was approved by ethics committees. We intend to publish the validated KIMs in 2018. Results will be published in peer-reviewed journals, presented at international meetings and disseminated to actual users for practical application. © Article

  12. Validation of the EIR LWR calculation methods for criticality assessment of storage pools

    International Nuclear Information System (INIS)

    Grimm, P.; Paratte, J.M.

    1986-11-01

    The EIR code system for the calculation of light water reactors is presented and the methods used are briefly described. The application of the system to various types of critical experiments and benchmark problems proves its good accuracy, even for heterogeneous configurations containing strong neutron absorbers such as Boral. Since the multiplication factor k eff is normally somewhat overpredicted and the spread of the results is small, this code system is validated for the calculation of storage pools, taking into account a safety margins of 1.5% on k eff . (author)

  13. Validation Results for LEWICE 3.0

    Science.gov (United States)

    Wright, William B.

    2005-01-01

    A research project is underway at NASA Glenn to produce computer software that can accurately predict ice growth under any meteorological conditions for any aircraft surface. This report will present results from version 3.0 of this software, which is called LEWICE. This version differs from previous releases in that it incorporates additional thermal analysis capabilities, a pneumatic boot model, interfaces to computational fluid dynamics (CFD) flow solvers and has an empirical model for the supercooled large droplet (SLD) regime. An extensive comparison of the results in a quantifiable manner against the database of ice shapes and collection efficiency that have been generated in the NASA Glenn Icing Research Tunnel (IRT) has also been performed. The complete set of data used for this comparison will eventually be available in a contractor report. This paper will show the differences in collection efficiency between LEWICE 3.0 and experimental data. Due to the large amount of validation data available, a separate report is planned for ice shape comparison. This report will first describe the LEWICE 3.0 model for water collection. A semi-empirical approach was used to incorporate first order physical effects of large droplet phenomena into icing software. Comparisons are then made to every single element two-dimensional case in the water collection database. Each condition was run using the following five assumptions: 1) potential flow, no splashing; 2) potential flow, no splashing with 21 bin drop size distributions and a lift correction (angle of attack adjustment); 3) potential flow, with splashing; 4) Navier-Stokes, no splashing; and 5) Navier-Stokes, with splashing. Quantitative comparisons are shown for impingement limit, maximum water catch, and total collection efficiency. The results show that the predicted results are within the accuracy limits of the experimental data for the majority of cases.

  14. Validation of verbal autopsy methods using hospital medical records: a case study in Vietnam.

    Science.gov (United States)

    Tran, Hong Thi; Nguyen, Hoa Phuong; Walker, Sue M; Hill, Peter S; Rao, Chalapati

    2018-05-18

    Information on causes of death (COD) is crucial for measuring the health outcomes of populations and progress towards the Sustainable Development Goals. In many countries such as Vietnam where the civil registration and vital statistics (CRVS) system is dysfunctional, information on vital events will continue to rely on verbal autopsy (VA) methods. This study assesses the validity of VA methods used in Vietnam, and provides recommendations on methods for implementing VA validation studies in Vietnam. This validation study was conducted on a sample of 670 deaths from a recent VA study in Quang Ninh province. The study covered 116 cases from this sample, which met three inclusion criteria: a) the death occurred within 30 days of discharge after last hospitalisation, and b) medical records (MRs) for the deceased were available from respective hospitals, and c) the medical record mentioned that the patient was terminally ill at discharge. For each death, the underlying cause of death (UCOD) identified from MRs was compared to the UCOD from VA. The validity of VA diagnoses for major causes of death was measured using sensitivity, specificity and positive predictive value (PPV). The sensitivity of VA was at least 75% in identifying some leading CODs such as stroke, road traffic accidents and several site-specific cancers. However, sensitivity was less than 50% for other important causes including ischemic heart disease, chronic obstructive pulmonary diseases, and diabetes. Overall, there was 57% agreement between UCOD from VA and MR, which increased to 76% when multiple causes from VA were compared to UCOD from MR. Our findings suggest that VA is a valid method to ascertain UCOD in contexts such as Vietnam. Furthermore, within cultural contexts in which patients prefer to die at home instead of a healthcare facility, using the available MRs as the gold standard may be meaningful to the extent that recall bias from the interval between last hospital discharge and death

  15. MR-based water content estimation in cartilage: design and validation of a method

    DEFF Research Database (Denmark)

    Shiguetomi Medina, Juan Manuel; Kristiansen, Maja Sophie; Ringgaard, Steffen

    Purpose: Design and validation of an MR-based method that allows the calculation of the water content in cartilage tissue. Methods and Materials: Cartilage tissue T1 map based water content MR sequences were used on a 37 Celsius degree stable system. The T1 map intensity signal was analyzed on 6...... cartilage samples from living animals (pig) and on 8 gelatin samples which water content was already known. For the data analysis a T1 intensity signal map software analyzer used. Finally, the method was validated after measuring and comparing 3 more cartilage samples in a living animal (pig). The obtained...... map based water content sequences can provide information that, after being analyzed using a T1-map analysis software, can be interpreted as the water contained inside a cartilage tissue. The amount of water estimated using this method was similar to the one obtained at the dry-freeze procedure...

  16. Clashing Validities in the Comparative Method? Balancing In-Depth Understanding and Generalizability in Small-N Policy Studies

    NARCIS (Netherlands)

    van der Heijden, J.

    2013-01-01

    The comparative method receives considerable attention in political science. To some a main advantage of the method is that it allows for both in-depth insights (internal validity), and generalizability beyond the cases studied (external validity). However, others consider internal and external

  17. Validation of a computational method for assessing the impact of intra-fraction motion on helical tomotherapy plans

    Energy Technology Data Exchange (ETDEWEB)

    Ngwa, Wilfred; Meeks, Sanford L; Kupelian, Patrick A; Langen, Katja M [Department of Radiation Oncology, M D Anderson Cancer Center Orlando, 1400 South Orange Avenue, Orlando, FL 32806 (United States); Schnarr, Eric [TomoTherapy, Inc., 1240 Deming Way, Madison, WI 53717 (United States)], E-mail: wilfred.ngwa@orlandohealth.com

    2009-11-07

    In this work, a method for direct incorporation of patient motion into tomotherapy dose calculations is developed and validated. This computational method accounts for all treatment dynamics and can incorporate random as well as cyclical motion data. Hence, interplay effects between treatment dynamics and patient motion are taken into account during dose calculation. This allows for a realistic assessment of intra-fraction motion on the dose distribution. The specific approach entails modifying the position and velocity events in the tomotherapy delivery plan to accommodate any known motion. The computational method is verified through phantom and film measurements. Here, measured prostate motion and simulated respiratory motion tracks were incorporated in the dose calculation. The calculated motion-encoded dose profiles showed excellent agreement with the measurements. Gamma analysis using 3 mm and 3% tolerance criteria showed over 97% and 96% average of points passing for the prostate and breathing motion tracks, respectively. The profile and gamma analysis results validate the accuracy of this method for incorporating intra-fraction motion into the dose calculation engine for assessment of dosimetric effects on helical tomotherapy dose deliveries.

  18. Validation of methods for measurement of insulin secretion in humans in vivo

    DEFF Research Database (Denmark)

    Kjems, L L; Christiansen, E; Vølund, A

    2000-01-01

    To detect and understand the changes in beta-cell function in the pathogenesis of type 2 diabetes, an accurate and precise estimation of prehepatic insulin secretion rate (ISR) is essential. There are two common methods to assess ISR, the deconvolution method (by Eaton and Polonsky)-considered th......To detect and understand the changes in beta-cell function in the pathogenesis of type 2 diabetes, an accurate and precise estimation of prehepatic insulin secretion rate (ISR) is essential. There are two common methods to assess ISR, the deconvolution method (by Eaton and Polonsky...... of these mathematical techniques for quantification of insulin secretion have been tested in dogs, but not in humans. In the present studies, we examined the validity of both methods to recover the known infusion rates of insulin and C-peptide mimicking ISR during an oral glucose tolerance test. ISR from both......, and a close agreement was found for the results of an oral glucose tolerance test. We also studied whether C-peptide kinetics are influenced by somatostatin infusion. The decay curves after bolus injection of exogenous biosynthetic human C-peptide, the kinetic parameters, and the metabolic clearance rate were...

  19. Experimental validation of the buildings energy performance (PEC assessment methods with reference to occupied spaces heating

    Directory of Open Access Journals (Sweden)

    Cristian PETCU

    2010-01-01

    provided by measurements and to those provided by the monthly calculation (NP 048-2006. The deviations of 1.45% and 2.2% respectively validate the hourly calculation model, as they actually have no physical significance. The report presents a phenomenological analysis of the building transfer functions synthesized as tev (τ, functions which attest their phenomenological objectivity in macro and hourly terms. The case studies completing the calculation models experimental validation emphasize unacceptably large differences between the results provided by the use of standardized calculation methods (Mc 001 / 2-2006 and SR EN 13790:2009 and those specific to the methods referred to in this report, experimentally validated.

  20. Fecal electrolyte testing for evaluation of unexplained diarrhea: Validation of body fluid test accuracy in the absence of a reference method.

    Science.gov (United States)

    Voskoboev, Nikolay V; Cambern, Sarah J; Hanley, Matthew M; Giesen, Callen D; Schilling, Jason J; Jannetto, Paul J; Lieske, John C; Block, Darci R

    2015-11-01

    Validation of tests performed on body fluids other than blood or urine can be challenging due to the lack of a reference method to confirm accuracy. The aim of this study was to evaluate alternate assessments of accuracy that laboratories can rely on to validate body fluid tests in the absence of a reference method using the example of sodium (Na(+)), potassium (K(+)), and magnesium (Mg(2+)) testing in stool fluid. Validations of fecal Na(+), K(+), and Mg(2+) were performed on the Roche cobas 6000 c501 (Roche Diagnostics) using residual stool specimens submitted for clinical testing. Spiked recovery, mixing studies, and serial dilutions were performed and % recovery of each analyte was calculated to assess accuracy. Results were confirmed by comparison to a reference method (ICP-OES, PerkinElmer). Mean recoveries for fecal electrolytes were Na(+) upon spiking=92%, mixing=104%, and dilution=105%; K(+) upon spiking=94%, mixing=96%, and dilution=100%; and Mg(2+) upon spiking=93%, mixing=98%, and dilution=100%. When autoanalyzer results were compared to reference ICP-OES results, Na(+) had a slope=0.94, intercept=4.1, and R(2)=0.99; K(+) had a slope=0.99, intercept=0.7, and R(2)=0.99; and Mg(2+) had a slope=0.91, intercept=-4.6, and R(2)=0.91. Calculated osmotic gap using both methods were highly correlated with slope=0.95, intercept=4.5, and R(2)=0.97. Acid pretreatment increased magnesium recovery from a subset of clinical specimens. A combination of mixing, spiking, and dilution recovery experiments are an acceptable surrogate for assessing accuracy in body fluid validations in the absence of a reference method. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  1. Principles of Single-Laboratory Validation of Analytical Methods for Testing the Chemical Composition of Pesticides

    Energy Technology Data Exchange (ETDEWEB)

    Ambrus, A. [Hungarian Food Safety Office, Budapest (Hungary)

    2009-07-15

    Underlying theoretical and practical approaches towards pesticide formulation analysis are discussed, i.e. general principles, performance characteristics, applicability of validation data, verification of method performance, and adaptation of validated methods by other laboratories. The principles of single laboratory validation of analytical methods for testing the chemical composition of pesticides are outlined. Also the theoretical background is described for performing pesticide formulation analysis as outlined in ISO, CIPAC/AOAC and IUPAC guidelines, including methodological characteristics such as specificity, selectivity, linearity, accuracy, trueness, precision and bias. Appendices I–III hereof give practical and elaborated examples on how to use the Horwitz approach and formulae for estimating the target standard deviation towards acceptable analytical repeatability. The estimation of trueness and the establishment of typical within-laboratory reproducibility are treated in greater detail by means of worked-out examples. (author)

  2. Transient FDTD simulation validation

    OpenAIRE

    Jauregui Tellería, Ricardo; Riu Costa, Pere Joan; Silva Martínez, Fernando

    2010-01-01

    In computational electromagnetic simulations, most validation methods have been developed until now to be used in the frequency domain. However, the EMC analysis of the systems in the frequency domain many times is not enough to evaluate the immunity of current communication devices. Based on several studies, in this paper we propose an alternative method of validation of the transients in time domain allowing a rapid and objective quantification of the simulations results.

  3. Reference Proteome Extracts for Mass Spec Instrument Performance Validation and Method Development

    Science.gov (United States)

    Rosenblatt, Mike; Urh, Marjeta; Saveliev, Sergei

    2014-01-01

    Biological samples of high complexity are required to test protein mass spec sample preparation procedures and validate mass spec instrument performance. Total cell protein extracts provide the needed sample complexity. However, to be compatible with mass spec applications, such extracts should meet a number of design requirements: compatibility with LC/MS (free of detergents, etc.)high protein integrity (minimal level of protein degradation and non-biological PTMs)compatibility with common sample preparation methods such as proteolysis, PTM enrichment and mass-tag labelingLot-to-lot reproducibility Here we describe total protein extracts from yeast and human cells that meet the above criteria. Two extract formats have been developed: Intact protein extracts with primary use for sample preparation method development and optimizationPre-digested extracts (peptides) with primary use for instrument validation and performance monitoring

  4. Validated spectrofluorometric method for determination of gemfibrozil in self nanoemulsifying drug delivery systems (SNEDDS)

    Science.gov (United States)

    Sierra Villar, Ana M.; Calpena Campmany, Ana C.; Bellowa, Lyda Halbaut; Trenchs, Monserrat Aróztegui; Naveros, Beatriz Clares

    2013-09-01

    A spectrofluorometric method has been developed and validated for the determination of gemfibrozil. The method is based on the excitation and emission capacities of gemfibrozil with excitation and emission wavelengths of 276 and 304 nm respectively. This method allows de determination of the drug in a self-nanoemulsifying drug delivery system (SNEDDS) for improve its intestinal absorption. Results obtained showed linear relationships with good correlation coefficients (r2 > 0.999) and low limits of detection and quantification (LOD of 0.075 μg mL-1 and LOQ of 0.226 μg mL-1) in the range of 0.2-5 μg mL-1, equally this method showed a good robustness and stability. Thus the amounts of gemfibrozil released from SNEDDS contained in gastro resistant hard gelatine capsules were analysed, and release studies could be performed satisfactorily.

  5. Low-cost extrapolation method for maximal LTE radio base station exposure estimation: test and validation.

    Science.gov (United States)

    Verloock, Leen; Joseph, Wout; Gati, Azeddine; Varsier, Nadège; Flach, Björn; Wiart, Joe; Martens, Luc

    2013-06-01

    An experimental validation of a low-cost method for extrapolation and estimation of the maximal electromagnetic-field exposure from long-term evolution (LTE) radio base station installations are presented. No knowledge on downlink band occupation or service characteristics is required for the low-cost method. The method is applicable in situ. It only requires a basic spectrum analyser with appropriate field probes without the need of expensive dedicated LTE decoders. The method is validated both in laboratory and in situ, for a single-input single-output antenna LTE system and a 2×2 multiple-input multiple-output system, with low deviations in comparison with signals measured using dedicated LTE decoders.

  6. Validation of three new methods for determination of metal emissions using a modified Environmental Protection Agency Method 301

    Energy Technology Data Exchange (ETDEWEB)

    Catherine A. Yanca; Douglas C. Barth; Krag A. Petterson; Michael P. Nakanishi; John A. Cooper; Bruce E. Johnsen; Richard H. Lambert; Daniel G. Bivins [Cooper Environmental Services, LLC, Portland, OR (United States)

    2006-12-15

    Three new methods applicable to the determination of hazardous metal concentrations in stationary source emissions were developed and evaluated for use in U.S. Environmental Protection Agency (EPA) compliance applications. Two of the three independent methods, a continuous emissions monitor-based method (Xact) and an X-ray-based filter method (XFM), are used to measure metal emissions. The third method involves a quantitative aerosol generator (QAG), which produces a reference aerosol used to evaluate the measurement methods. A modification of EPA Method 301 was used to validate the three methods for As, Cd, Cr, Pb, and Hg, representing three hazardous waste combustor Maximum Achievable Control Technology (MACT) metal categories (low volatile, semivolatile, and volatile). The measurement methods were evaluated at a hazardous waste combustor (HWC) by comparing measured with reference aerosol concentrations. The QAG, Xact, and XFM met the modified Method 301 validation criteria. All three of the methods demonstrated precisions and accuracies on the order of 5%. The measurement methods should be applicable to emissions from a wide range of sources, and the reference aerosol generator should be applicable to additional analytes. EPA recently approved an alternative monitoring petition for an HWC at Eli Lilly's Tippecanoe site in Lafayette, IN, in which the Xact is used for demonstrating compliance with the HWC MACT metal emissions (low volatile, semivolatile, and volatile). The QAG reference aerosol generator was approved as a method for providing a quantitative reference aerosol, which is required for certification and continuing quality assurance of the Xact. 30 refs., 5 figs., 11 tabs.

  7. Validation of Multilevel Constructs: Validation Methods and Empirical Findings for the EDI

    Science.gov (United States)

    Forer, Barry; Zumbo, Bruno D.

    2011-01-01

    The purposes of this paper are to highlight the foundations of multilevel construct validation, describe two methodological approaches and associated analytic techniques, and then apply these approaches and techniques to the multilevel construct validation of a widely-used school readiness measure called the Early Development Instrument (EDI;…

  8. Fisk-based criteria to support validation of detection methods for drinking water and air.

    Energy Technology Data Exchange (ETDEWEB)

    MacDonell, M.; Bhattacharyya, M.; Finster, M.; Williams, M.; Picel, K.; Chang, Y.-S.; Peterson, J.; Adeshina, F.; Sonich-Mullin, C.; Environmental Science Division; EPA

    2009-02-18

    This report was prepared to support the validation of analytical methods for threat contaminants under the U.S. Environmental Protection Agency (EPA) National Homeland Security Research Center (NHSRC) program. It is designed to serve as a resource for certain applications of benchmark and fate information for homeland security threat contaminants. The report identifies risk-based criteria from existing health benchmarks for drinking water and air for potential use as validation targets. The focus is on benchmarks for chronic public exposures. The priority sources are standard EPA concentration limits for drinking water and air, along with oral and inhalation toxicity values. Many contaminants identified as homeland security threats to drinking water or air would convert to other chemicals within minutes to hours of being released. For this reason, a fate analysis has been performed to identify potential transformation products and removal half-lives in air and water so appropriate forms can be targeted for detection over time. The risk-based criteria presented in this report to frame method validation are expected to be lower than actual operational targets based on realistic exposures following a release. Note that many target criteria provided in this report are taken from available benchmarks without assessing the underlying toxicological details. That is, although the relevance of the chemical form and analogues are evaluated, the toxicological interpretations and extrapolations conducted by the authoring organizations are not. It is also important to emphasize that such targets in the current analysis are not health-based advisory levels to guide homeland security responses. This integrated evaluation of chronic public benchmarks and contaminant fate has identified more than 200 risk-based criteria as method validation targets across numerous contaminants and fate products in drinking water and air combined. The gap in directly applicable values is

  9. Transcriptomic SNP discovery for custom genotyping arrays: impacts of sequence data, SNP calling method and genotyping technology on the probability of validation success.

    Science.gov (United States)

    Humble, Emily; Thorne, Michael A S; Forcada, Jaume; Hoffman, Joseph I

    2016-08-26

    Single nucleotide polymorphism (SNP) discovery is an important goal of many studies. However, the number of 'putative' SNPs discovered from a sequence resource may not provide a reliable indication of the number that will successfully validate with a given genotyping technology. For this it may be necessary to account for factors such as the method used for SNP discovery and the type of sequence data from which it originates, suitability of the SNP flanking sequences for probe design, and genomic context. To explore the relative importance of these and other factors, we used Illumina sequencing to augment an existing Roche 454 transcriptome assembly for the Antarctic fur seal (Arctocephalus gazella). We then mapped the raw Illumina reads to the new hybrid transcriptome using BWA and BOWTIE2 before calling SNPs with GATK. The resulting markers were pooled with two existing sets of SNPs called from the original 454 assembly using NEWBLER and SWAP454. Finally, we explored the extent to which SNPs discovered using these four methods overlapped and predicted the corresponding validation outcomes for both Illumina Infinium iSelect HD and Affymetrix Axiom arrays. Collating markers across all discovery methods resulted in a global list of 34,718 SNPs. However, concordance between the methods was surprisingly poor, with only 51.0 % of SNPs being discovered by more than one method and 13.5 % being called from both the 454 and Illumina datasets. Using a predictive modeling approach, we could also show that SNPs called from the Illumina data were on average more likely to successfully validate, as were SNPs called by more than one method. Above and beyond this pattern, predicted validation outcomes were also consistently better for Affymetrix Axiom arrays. Our results suggest that focusing on SNPs called by more than one method could potentially improve validation outcomes. They also highlight possible differences between alternative genotyping technologies that could be

  10. The truncated Wigner method for Bose-condensed gases: limits of validity and applications

    International Nuclear Information System (INIS)

    Sinatra, Alice; Lobo, Carlos; Castin, Yvan

    2002-01-01

    We study the truncated Wigner method applied to a weakly interacting spinless Bose-condensed gas which is perturbed away from thermal equilibrium by a time-dependent external potential. The principle of the method is to generate an ensemble of classical fields ψ(r) which samples the Wigner quasi-distribution function of the initial thermal equilibrium density operator of the gas, and then to evolve each classical field with the Gross-Pitaevskii equation. In the first part of the paper we improve the sampling technique over our previous work (Sinatra et al 2000 J. Mod. Opt. 47 2629-44) and we test its accuracy against the exactly solvable model of the ideal Bose gas. In the second part of the paper we investigate the conditions of validity of the truncated Wigner method. For short evolution times it is known that the time-dependent Bogoliubov approximation is valid for almost pure condensates. The requirement that the truncated Wigner method reproduces the Bogoliubov prediction leads to the constraint that the number of field modes in the Wigner simulation must be smaller than the number of particles in the gas. For longer evolution times the nonlinear dynamics of the noncondensed modes of the field plays an important role. To demonstrate this we analyse the case of a three-dimensional spatially homogeneous Bose-condensed gas and we test the ability of the truncated Wigner method to correctly reproduce the Beliaev-Landau damping of an excitation of the condensate. We have identified the mechanism which limits the validity of the truncated Wigner method: the initial ensemble of classical fields, driven by the time-dependent Gross-Pitaevskii equation, thermalizes to a classical field distribution at a temperature T class which is larger than the initial temperature T of the quantum gas. When T class significantly exceeds T a spurious damping is observed in the Wigner simulation. This leads to the second validity condition for the truncated Wigner method, T class - T

  11. Pressurised liquid extraction of flavonoids in onions. Method development and validation

    DEFF Research Database (Denmark)

    Søltoft, Malene; Christensen, J.H.; Nielsen, J.

    2009-01-01

    A rapid and reliable analytical method for quantification of flavonoids in onions was developed and validated. Five extraction methods were tested on freeze-dried onions and subsequently high performance liquid chromatography (HPLC) with UV detection was used for quantification of seven flavonoids...... extraction methods. However. PLE was the preferred extraction method because the method can be highly automated, use only small amounts of solvents, provide the cleanest extracts, and allow the extraction of light and oxygen-sensitive flavonoids to be carried out in an inert atmosphere protected from light......-step PLE method showed good selectivity, precision (RSDs = 3.1-11%) and recovery of the extractable flavonoids (98-99%). The method also appeared to be a multi-method, i.e. generally applicable to, e.g. phenolic acids in potatoes and carrots....

  12. Application of EU guidelines for the validation of screening methods for veterinary drugs

    NARCIS (Netherlands)

    Stolker, A.A.M.

    2012-01-01

    Commission Decision (CD) 2002/657/EC describes detailed rules for method validation within the framework of residue monitoring programmes. The approach described in this CD is based on criteria. For (qualitative) screening methods, the most important criteria is that the CCß has to be below any

  13. Analytical method development and validation of spectrofluorimetric and spectrophotometric determination of some antimicrobial drugs in their pharmaceuticals

    Science.gov (United States)

    Ibrahim, F.; Wahba, M. E. K.; Magdy, G.

    2018-01-01

    In this study, three novel, sensitive, simple and validated spectrophotometric and spectrofluorimetric methods have been proposed for estimation of some important antimicrobial drugs. The first two methods have been proposed for estimation of two important third-generation cephalosporin antibiotics namely, cefixime and cefdinir. Both methods were based on condensation of the primary amino group of the studied drugs with acetyl acetone and formaldehyde in acidic medium. The resulting products were measured by spectrophotometric (Method I) and spectrofluorimetric (Method II) tools. Regarding method I, the absorbance was measured at 315 nm and 403 nm with linearity ranges of 5.0-140.0 and 10.0-100.0 μg/mL for cefixime and cefdinir, respectively. Meanwhile in method II, the produced fluorophore was measured at λem 488 nm or 491 nm after excitation at λex 410 nm with linearity ranges of 0.20-10.0 and 0.20-36.0 μg/mL for cefixime and cefdinir, respectively. On the other hand, method III was devoted to estimate nifuroxazide spectrofluorimetrically depending on formation of highly fluorescent product upon reduction of the studied drug with Zinc powder in acidic medium. Measurement of the fluorescent product was carried out at λem 335 nm following excitation at λex 255 nm with linearity range of 0.05 to 1.6 μg/mL. The developed methods were subjected to detailed validation procedure, moreover they were used for the estimation of the concerned drugs in their pharmaceuticals. It was found that there is a good agreement between the obtained results and those obtained by the reported methods.

  14. Validation of the cleaning and sanitization method for radiopharmaceutical production facilities

    International Nuclear Information System (INIS)

    Robles, Anita; Morote, Mario; Moore, Mariel; Castro, Delcy; Paragulla, Wilson; Novoa, Carlos; Otero, Manuel; Miranda, Jesus; Herrera, Jorge; Gonzales, Luis

    2014-01-01

    A protocol for the cleaning and sanitization method for radiopharmaceutical production facilities has been designed and developed for the inner surface of the hot cells for the production of Sodium Pertechnetate Tc-99m and Sm-153 EDTMP, considering an extreme situation for each hot cell. Cleaning is performed with double-distilled water and sanitation with two disinfectant solutions, 70 % isopropyl alcohol and 3 % hydrogen peroxide in alternate weeks. Microbiological analysis of sanitized surfaces were made after 20 minutes and 48 hours for the hot cell of Tc-99m and 72 hours for the hot cell of EDTMP Sm-153 in 3 consecutive tests by the method of direct contact with plates containing culture medium, made for each sampling point (6 in the first and five in the second). The results showed that the microbial load on surfaces sanitized was below acceptable limits and that the lifetime of cleaning and sanitization is 48 hours for the hot cell of Tc-99m and 72 hours for the one of EDTMP-Sm-153. As a conclusion, the method of cleaning and sanitization is effective to reduce or eliminate microbial contamination therefore, the process is validated. (authors).

  15. A systematic review and appraisal of methods of developing and validating lifestyle cardiovascular disease risk factors questionnaires.

    Science.gov (United States)

    Nse, Odunaiya; Quinette, Louw; Okechukwu, Ogah

    2015-09-01

    Well developed and validated lifestyle cardiovascular disease (CVD) risk factors questionnaires is the key to obtaining accurate information to enable planning of CVD prevention program which is a necessity in developing countries. We conducted this review to assess methods and processes used for development and content validation of lifestyle CVD risk factors questionnaires and possibly develop an evidence based guideline for development and content validation of lifestyle CVD risk factors questionnaires. Relevant databases at the Stellenbosch University library were searched for studies conducted between 2008 and 2012, in English language and among humans. Using the following databases; pubmed, cinahl, psyc info and proquest. Search terms used were CVD risk factors, questionnaires, smoking, alcohol, physical activity and diet. Methods identified for development of lifestyle CVD risk factors were; review of literature either systematic or traditional, involvement of expert and /or target population using focus group discussion/interview, clinical experience of authors and deductive reasoning of authors. For validation, methods used were; the involvement of expert panel, the use of target population and factor analysis. Combination of methods produces questionnaires with good content validity and other psychometric properties which we consider good.

  16. Application of Bayesian Method in Validation of TTM Decisional Balance and Self-Efficacy Constructs to Improve Nutritional Behavior in Yazdian Prediabetes

    Directory of Open Access Journals (Sweden)

    Hossein Fallahzadeh

    2017-07-01

    Full Text Available Introduction: To introduce Bayesian method in validation of transtheoretical model’s Self-Efficacy and Decisional Balance for nutritional behavior improvement among Prediabetes with ordinal data. Methods: This is an Experimental trial with parallel design and sample was included 220 Prediabetes who Participated in screening program and had over 30 years old, fasting blood glucose ranged 100-125 and at least elementary Education. We used OpenBugs 3.2.3 to fit Bayesian ordinal factor analysis to achieve validation of TTM’s decisional balance and self-efficacy. Results: All of the factor loadings corresponded to mentioned constructs was significant at α= 0.05%. That support validation of the Constructs. Correlation between Pros and Cons was not significant(-0.076, 0.007.Furthermore a specific statistical model for ordinal data created that can estimate odds ratios and marginal Probabilities for each choice of any item in questionnaire. Conclusion: Thanks to benefits of Bayesian method in use of prior information such as Meta-analysis and other resources, In comparison to similar studies that used standard or other factor analysis for ordinal data, our results had good accuracy(with aspect to standard deviation even with lower sample size.so the results can be used  in future clinical researches.

  17. Determination of total arsenic in fish by hydride-generation atomic absorption spectrometry: method validation, traceability and uncertainty evaluation

    Science.gov (United States)

    Nugraha, W. C.; Elishian, C.; Ketrin, R.

    2017-03-01

    Fish containing arsenic compound is one of the important indicators of arsenic contamination in water monitoring. The high level of arsenic in fish is due to absorption through food chain and accumulated in their habitat. Hydride generation (HG) coupled with atomic absorption spectrometric (AAS) detection is one of the most popular techniques employed for arsenic determination in a variety of matrices including fish. This study aimed to develop a method for the determination of total arsenic in fish by HG-AAS. The method for sample preparation from American of Analytical Chemistry (AOAC) Method 999.10-2005 was adopted for acid digestion using microwave digestion system and AOAC Method 986.15 - 2005 for dry ashing. The method was developed and validated using Certified Reference Material DORM 3 Fish Protein for trace metals for ensuring the accuracy and the traceability of the results. The sources of uncertainty of the method were also evaluated. By using the method, it was found that the total arsenic concentration in the fish was 45.6 ± 1.22 mg.Kg-1 with a coverage factor of equal to 2 at 95% of confidence level. Evaluation of uncertainty was highly influenced by the calibration curve. This result was also traceable to International Standard System through analysis of Certified Reference Material DORM 3 with 97.5% of recovery. In summary, it showed that method of preparation and HG-AAS technique for total arsenic determination in fish were valid and reliable.

  18. Method validation to determine total alpha beta emitters in water samples using LSC

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.; Al-akel, B.; Saaid, S.

    2006-06-01

    In this work a method was validated to determine gross alpha and beta emitters in water samples using liquid scintillation counter. 200 ml of water from each sample were evaporated to 20 ml and 8 ml of them were mixed with 12 ml of the suitable cocktail to be measured by liquid scintillation counter Wallac Winspectral 1414. The lower detection limit by this method (LDL) was 0.33 DPM for total alpha emitters and 1.3 DPM for total beta emitters. and the reproducibility limit was (± 2.32 DPM) and (±1.41 DPM) for total alpha and beta emitters respectively, and the repeatability limit was (±2.19 DPM) and (±1.11 DPM) for total alpha and beta emitters respectively. The method is easy and fast because of the simple preparation steps and the large number of samples that can be measured at the same time. In addition, many real samples and standard samples were analyzed by the method and showed accurate results so it was concluded that the method can be used with various water samples. (author)

  19. Safety evaluations required in the safety regulations for Monju and the validity confirmation of safety evaluation methods

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    The purposes of this study are to perform the safety evaluations of the fast breeder reactor 'Monju' and to confirm the validity of the safety evaluation methods. In JFY 2012, the following results were obtained. As for the development of safety evaluation methods needed in the safety examination achieved for the reactor establishment permission, development of the analysis codes, such as a core damage analysis code, were carried out according to the plan. As for the development of the safety evaluation method needed for the risk informed safety regulation, the quantification technique of the event tree using the Continuous Markov chain Monte Carlo method (CMMC method) were studied. (author)

  20. An Anatomically Validated Brachial Plexus Contouring Method for Intensity Modulated Radiation Therapy Planning

    International Nuclear Information System (INIS)

    Van de Velde, Joris; Audenaert, Emmanuel; Speleers, Bruno; Vercauteren, Tom; Mulliez, Thomas; Vandemaele, Pieter; Achten, Eric; Kerckaert, Ingrid; D'Herde, Katharina; De Neve, Wilfried; Van Hoof, Tom

    2013-01-01

    Purpose: To develop contouring guidelines for the brachial plexus (BP) using anatomically validated cadaver datasets. Magnetic resonance imaging (MRI) and computed tomography (CT) were used to obtain detailed visualizations of the BP region, with the goal of achieving maximal inclusion of the actual BP in a small contoured volume while also accommodating for anatomic variations. Methods and Materials: CT and MRI were obtained for 8 cadavers positioned for intensity modulated radiation therapy. 3-dimensional reconstructions of soft tissue (from MRI) and bone (from CT) were combined to create 8 separate enhanced CT project files. Dissection of the corresponding cadavers anatomically validated the reconstructions created. Seven enhanced CT project files were then automatically fitted, separately in different regions, to obtain a single dataset of superimposed BP regions that incorporated anatomic variations. From this dataset, improved BP contouring guidelines were developed. These guidelines were then applied to the 7 original CT project files and also to 1 additional file, left out from the superimposing procedure. The percentage of BP inclusion was compared with the published guidelines. Results: The anatomic validation procedure showed a high level of conformity for the BP regions examined between the 3-dimensional reconstructions generated and the dissected counterparts. Accurate and detailed BP contouring guidelines were developed, which provided corresponding guidance for each level in a clinical dataset. An average margin of 4.7 mm around the anatomically validated BP contour is sufficient to accommodate for anatomic variations. Using the new guidelines, 100% inclusion of the BP was achieved, compared with a mean inclusion of 37.75% when published guidelines were applied. Conclusion: Improved guidelines for BP delineation were developed using combined MRI and CT imaging with validation by anatomic dissection

  1. A Framework for Mixing Methods in Quantitative Measurement Development, Validation, and Revision: A Case Study

    Science.gov (United States)

    Luyt, Russell

    2012-01-01

    A framework for quantitative measurement development, validation, and revision that incorporates both qualitative and quantitative methods is introduced. It extends and adapts Adcock and Collier's work, and thus, facilitates understanding of quantitative measurement development, validation, and revision as an integrated and cyclical set of…

  2. Unexpected but Most Welcome: Mixed Methods for the Validation and Revision of the Participatory Evaluation Measurement Instrument

    Science.gov (United States)

    Daigneault, Pierre-Marc; Jacob, Steve

    2014-01-01

    Although combining methods is nothing new, more contributions about why and how to mix methods for validation purposes are needed. This article presents a case of validating the inferences drawn from the Participatory Evaluation Measurement Instrument, an instrument that purports to measure stakeholder participation in evaluation. Although the…

  3. Development and validation of a multiresidue method for pesticide analysis in honey by UFLC-MS

    Directory of Open Access Journals (Sweden)

    Adriana M. Zamudio S.

    2017-05-01

    Full Text Available A method for the determination of pesticide residues in honey by ultra fast liquid chromatography coupled with mass spectrometry was developed. For this purpose, different variations of the QuECHERS method were performed: (i amount of sample, (ii type of salt to control pH, (iii buffer pH, and (iv different mixtures for cleaning-up. In addition, to demonstrate that the method is reliable, different validation parameters were studied: accuracy, limits of detection and quantification, linearity and selectivity. The results showed that by means of the changes introduced it was possible to get a more selective method that improves the accuracy of about 19 pesticides selected from the original method. It was found that the method is suitable for the analysis of 50 pesticides, out of 56. Furthermore, with the developed method recoveries between 70 and 120% and relative standard deviation below 15% were found.

  4. First results of Minimum Fisher Regularisation as unfolding method for JET NE213 liquid scintillator neutron spectrometry

    International Nuclear Information System (INIS)

    Mlynar, Jan; Adams, John M.; Bertalot, Luciano; Conroy, Sean

    2005-01-01

    At JET, the NE213 liquid scintillator is being validated as a diagnostic tool for spectral measurements of neutrons emitted from the plasma. Neutron spectra have to be unfolded from the measured pulse-height spectra, which is an ill-conditioned problem. Therefore, use of two independent unfolding methods allows for less ambiguity on the interpretation of the data. In parallel to the routine algorithm MAXED based on the Maximum Entropy method, the Minimum Fisher Regularisation (MFR) method has been introduced at JET. The MFR method, known from two-dimensional tomography applications, has proved to provide a new transparent tool to validate the JET neutron spectra measured with the NE213 liquid scintillators. In this article, the MFR method applicable to spectra unfolding is briefly explained. After a mention of MFR tests on phantom spectra experimental neutron spectra are presented that were obtained by applying MFR to NE213 data in selected JET experiments. The results tend to confirm MAXED observations

  5. MLFMA-accelerated Nyström method for ultrasonic scattering - Numerical results and experimental validation

    Science.gov (United States)

    Gurrala, Praveen; Downs, Andrew; Chen, Kun; Song, Jiming; Roberts, Ron

    2018-04-01

    Full wave scattering models for ultrasonic waves are necessary for the accurate prediction of voltage signals received from complex defects/flaws in practical nondestructive evaluation (NDE) measurements. We propose the high-order Nyström method accelerated by the multilevel fast multipole algorithm (MLFMA) as an improvement to the state-of-the-art full-wave scattering models that are based on boundary integral equations. We present numerical results demonstrating improvements in simulation time and memory requirement. Particularly, we demonstrate the need for higher order geom-etry and field approximation in modeling NDE measurements. Also, we illustrate the importance of full-wave scattering models using experimental pulse-echo data from a spherical inclusion in a solid, which cannot be modeled accurately by approximation-based scattering models such as the Kirchhoff approximation.

  6. Assessing the Validity of Single-item Life Satisfaction Measures: Results from Three Large Samples

    Science.gov (United States)

    Cheung, Felix; Lucas, Richard E.

    2014-01-01

    Purpose The present paper assessed the validity of single-item life satisfaction measures by comparing single-item measures to the Satisfaction with Life Scale (SWLS) - a more psychometrically established measure. Methods Two large samples from Washington (N=13,064) and Oregon (N=2,277) recruited by the Behavioral Risk Factor Surveillance System (BRFSS) and a representative German sample (N=1,312) recruited by the Germany Socio-Economic Panel (GSOEP) were included in the present analyses. Single-item life satisfaction measures and the SWLS were correlated with theoretically relevant variables, such as demographics, subjective health, domain satisfaction, and affect. The correlations between the two life satisfaction measures and these variables were examined to assess the construct validity of single-item life satisfaction measures. Results Consistent across three samples, single-item life satisfaction measures demonstrated substantial degree of criterion validity with the SWLS (zero-order r = 0.62 – 0.64; disattenuated r = 0.78 – 0.80). Patterns of statistical significance for correlations with theoretically relevant variables were the same across single-item measures and the SWLS. Single-item measures did not produce systematically different correlations compared to the SWLS (average difference = 0.001 – 0.005). The average absolute difference in the magnitudes of the correlations produced by single-item measures and the SWLS were very small (average absolute difference = 0.015 −0.042). Conclusions Single-item life satisfaction measures performed very similarly compared to the multiple-item SWLS. Social scientists would get virtually identical answer to substantive questions regardless of which measure they use. PMID:24890827

  7. Development and Validation of New Spectrophotometric Methods to Determine Enrofloxacin in Pharmaceuticals

    Science.gov (United States)

    Rajendraprasad, N.; Basavaiah, K.

    2015-07-01

    Four spectrophotometric methods, based on oxidation with cerium(IV), are investigated and developed to determine EFX in pure form and in dosage forms. The frst and second methods (Method A and method B) are direct, in which after the oxidation of EFX with cerium(IV) in acid medium, the absorbance of reduced and unreacted oxidant is measured at 275 and 320 nm, respectively. In the third (C) and fourth (D) methods after the reaction between EFX and oxidant is ensured to be completed the surplus oxidant is treated with either N-phenylanthranilic acid (NPA) or Alizarin Red S (ARS) dye and the absorbance of the oxidized NPA or ARS is measured at 440 or 420 nm. The methods showed good linearity over the concentration ranges of 0.5-5.0, 1.25-12.5, 10.0-100.0, and 6.0-60.0 μg/ml, for method A, B, C and D, respectively, with apparent molar absorptivity values of 4.42 × 10 4 , 8.7 × 10 3 , 9.31 × 10 2 , and 2.28 × 10 3 l/(mol· cm). The limits of detection (LOD), quantification (LOQ), and Sandell's sensitivity values and other validation results have also been reported. The proposed methods are successfully applied to determine EFX in pure form and in dosage forms.

  8. Validity and Interrater Reliability of the Visual Quarter-Waste Method for Assessing Food Waste in Middle School and High School Cafeteria Settings.

    Science.gov (United States)

    Getts, Katherine M; Quinn, Emilee L; Johnson, Donna B; Otten, Jennifer J

    2017-11-01

    Measuring food waste (ie, plate waste) in school cafeterias is an important tool to evaluate the effectiveness of school nutrition policies and interventions aimed at increasing consumption of healthier meals. Visual assessment methods are frequently applied in plate waste studies because they are more convenient than weighing. The visual quarter-waste method has become a common tool in studies of school meal waste and consumption, but previous studies of its validity and reliability have used correlation coefficients, which measure association but not necessarily agreement. The aims of this study were to determine, using a statistic measuring interrater agreement, whether the visual quarter-waste method is valid and reliable for assessing food waste in a school cafeteria setting when compared with the gold standard of weighed plate waste. To evaluate validity, researchers used the visual quarter-waste method and weighed food waste from 748 trays at four middle schools and five high schools in one school district in Washington State during May 2014. To assess interrater reliability, researcher pairs independently assessed 59 of the same trays using the visual quarter-waste method. Both validity and reliability were assessed using a weighted κ coefficient. For validity, as compared with the measured weight, 45% of foods assessed using the visual quarter-waste method were in almost perfect agreement, 42% of foods were in substantial agreement, 10% were in moderate agreement, and 3% were in slight agreement. For interrater reliability between pairs of visual assessors, 46% of foods were in perfect agreement, 31% were in almost perfect agreement, 15% were in substantial agreement, and 8% were in moderate agreement. These results suggest that the visual quarter-waste method is a valid and reliable tool for measuring plate waste in school cafeteria settings. Copyright © 2017 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  9. 42 CFR 493.571 - Disclosure of accreditation, State and CMS validation inspection results.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Disclosure of accreditation, State and CMS... Program § 493.571 Disclosure of accreditation, State and CMS validation inspection results. (a) Accreditation organization inspection results. CMS may disclose accreditation organization inspection results to...

  10. Performance Validity Testing in Neuropsychology: Methods for Measurement Development and Maximizing Diagnostic Accuracy.

    Science.gov (United States)

    Wodushek, Thomas R; Greher, Michael R

    2017-05-01

    In the first column in this 2-part series, Performance Validity Testing in Neuropsychology: Scientific Basis and Clinical Application-A Brief Review, the authors introduced performance validity tests (PVTs) and their function, provided a justification for why they are necessary, traced their ongoing endorsement by neuropsychological organizations, and described how they are used and interpreted by ever increasing numbers of clinical neuropsychologists. To enhance readers' understanding of these measures, this second column briefly describes common detection strategies used in PVTs as well as the typical methods used to validate new PVTs and determine cut scores for valid/invalid determinations. We provide a discussion of the latest research demonstrating how neuropsychologists can combine multiple PVTs in a single battery to improve sensitivity/specificity to invalid responding. Finally, we discuss future directions for the research and application of PVTs.

  11. Validation of a dissolution method with RP-HPLC analysis for Perindopril erbumine and Indapamide combination tablet

    Directory of Open Access Journals (Sweden)

    Jain P.S.

    2012-01-01

    Full Text Available A Dissolution method with high performance liquid chromatography (HPLC analysis was validated for perindopril erbumine and indapamide in combination tablet formulation. The method was validated to meet requirements for a global regulatory filing and this validation included specificity, linearity, accuracy, precision, range, robustness and solution stability studies. The dissolution method, which uses USP apparatus 1 with basket rotating at 100 rpm, 1000 ml of phosphate buffer pH 6.8 as the dissolution medium, and reversed-phased HPLC was carried out at 50⁰C on a 4.6mm×250mm 5μm cyano column that contained USP packing L1 with acetonitrile: buffer pH 2.8::40:60 (v/v, as mobile phase. UV detector was set at 225 nm. A method was found to be selective, linear, accurate and precise in the specified ranges. Intra-day and inter-day variability for method was <2% RSD. This method was successfully used for quantification of perindopril erbumine and indapamide combination tablet formulations.

  12. Low-cost extrapolation method for maximal lte radio base station exposure estimation: Test and validation

    International Nuclear Information System (INIS)

    Verloock, L.; Joseph, W.; Gati, A.; Varsier, N.; Flach, B.; Wiart, J.; Martens, L.

    2013-01-01

    An experimental validation of a low-cost method for extrapolation and estimation of the maximal electromagnetic-field exposure from long-term evolution (LTE) radio base station installations are presented. No knowledge on down-link band occupation or service characteristics is required for the low-cost method. The method is applicable in situ. It only requires a basic spectrum analyser with appropriate field probes without the need of expensive dedicated LTE decoders. The method is validated both in laboratory and in situ, for a single-input single-output antenna LTE system and a 2x2 multiple-input multiple-output system, with low deviations in comparison with signals measured using dedicated LTE decoders. (authors)

  13. Review on Laryngeal Palpation Methods in Muscle Tension Dysphonia: Validity and Reliability Issues.

    Science.gov (United States)

    Khoddami, Seyyedeh Maryam; Ansari, Noureddin Nakhostin; Jalaie, Shohreh

    2015-07-01

    Laryngeal palpation is a common clinical method for the assessment of neck and laryngeal muscles in muscle tension dysphonia (MTD). To review the available laryngeal palpation methods used in patients with MTD for the assessment, diagnosis, or document of treatment outcomes. A systematic review of the literature concerning palpatory methods in MTD was conducted using the databases MEDLINE (PubMed), ScienceDirect, Scopus, Web of science, Web of knowledge and Cochrane Library between July and October 2013. Relevant studies were identified by one reviewer based on screened titles/abstracts and full texts. Manual searching was also used to track the source literature. There were five main as well as miscellaneous palpation methods that were different according to target anatomical structures, judgment or grading system, and using tasks. There were only a few scales available, and the majority of the palpatory methods were qualitative. Most of the palpatory methods evaluate the tension at both static and dynamic tasks. There was little information about the validity and reliability of the available methods. The literature on the scientific evidence of muscle tension indicators perceived by laryngeal palpation in MTD is scarce. Future studies should be conducted to investigate the validity and reliability of palpation methods. Copyright © 2015 The Voice Foundation. Published by Elsevier Inc. All rights reserved.

  14. Multi-Trait Multi-Method Matrices for the Validation of Creativity and Critical Thinking Assessments for Secondary School Students in England and Greece

    Directory of Open Access Journals (Sweden)

    Ourania Maria Ventista

    2017-08-01

    Full Text Available The aim of this paper is the validation of measurement tools which assess critical thinking and creativity as general constructs instead of subject-specific skills. Specifically, this research examined whether there is convergent and discriminant (or divergent validity between measurement tools of creativity and critical thinking. For this purpose, the multi-trait and multi-method matrix suggested by Campbell and Fiske (1959 was used. This matrix presented the correlation of scores that students obtain in different assessments in order to reveal whether the assessments measure the same or different constructs. Specifically, the two methods used were written and oral exams, and the two traits measured were critical thinking and creativity. For the validation of the assessments, 30 secondary-school students in Greece and 21 in England completed the assessments. The sample in both countries provided similar results. The critical thinking tools demonstrated convergent validity when compared with each other and discriminant validity with the creativity assessments. Furthermore, creativity assessments which measure the same aspect of creativity demonstrated convergent validity. To conclude, this research provided indicators that critical thinking and creativity as general constructs can be measured in a valid way. However, since the sample was small, further investigation of the validation of the assessment tools with a bigger sample is recommended.

  15. The fish sexual development test: an OECD test guideline proposal with possible relevance for environmental risk assessment. Results from the validation programme

    DEFF Research Database (Denmark)

    Holbech, Henrik; Brande-Lavridsen, Nanna; Kinnberg, Karin Lund

    2010-01-01

    The Fish Sexual Development Test (FSDT) has gone through two validations as an OECD test guideline for the detection of endocrine active chemicals with different modes of action. The validation has been finalized on four species: Zebrafish (Danio rerio), Japanese medaka (Oryzias latipes), three s...... as a population relevant endpoint and the results of the two validation rounds will be discussed in relation to environmental risk assessment and species selection....... for histology. For all three methods, the fish parts were numbered and histology could therefore be linked to the vitellogenin concentration in individual fish. The two core endocrine relevant endpoints were vitellogenin concentrations and phenotypic sex ratio. Change in the sex ratio is presented...

  16. Validation of quantitative 1H NMR method for the analysis of pharmaceutical formulations

    International Nuclear Information System (INIS)

    Santos, Maiara da S.

    2013-01-01

    The need for effective and reliable quality control in products from pharmaceutical industries renders the analyses of their active ingredients and constituents of great importance. This study presents the theoretical basis of ¹H NMR for quantitative analyses and an example of the method validation according to Resolution RE N. 899 by the Brazilian National Health Surveillance Agency (ANVISA), in which the compound paracetamol was the active ingredient. All evaluated parameters (selectivity, linearity, accuracy, repeatability and robustness) showed satisfactory results. It was concluded that a single NMR measurement provides structural and quantitative information of active components and excipients in the sample. (author)

  17. Validation of the method for determination of the thermal resistance of fouling in shell and tube heat exchangers

    International Nuclear Information System (INIS)

    Markowski, Mariusz; Trafczynski, Marian; Urbaniec, Krzysztof

    2013-01-01

    Highlights: • Heat recovery in a heat exchanger network (HEN). • A novel method for on-line determination of the thermal resistance of fouling is presented. • Details are developed for shell and tube heat exchangers. • The method was validated and sensibility analysis was carried out. • Developed approach allows long-term monitoring of changes in the HEN efficiency. - Abstract: A novel method for on-line determination of the thermal resistance of fouling in shell and tube heat exchangers is presented. It can be applied under the condition that the data on pressure, temperature, mass flowrate and thermophysical properties of both heat-exchanging media are continuously available. The calculation algorithm for use in the novel method is robust and ensures reliable determination of the thermal resistance of fouling even if the operating parameters fluctuate. The method was validated using measurement data retrieved from the operation records of a heat exchanger network connected with a crude distillation unit rated 800 t/h. Sensibility analysis of the method was carried out and the calculated values of the thermal resistance of fouling were critically reviewed considering the results of qualitative evaluation of fouling layers in the exchangers inspected during plant overhaul

  18. Performance of the Tariff Method: validation of a simple additive algorithm for analysis of verbal autopsies

    Directory of Open Access Journals (Sweden)

    Murray Christopher JL

    2011-08-01

    Full Text Available Abstract Background Verbal autopsies provide valuable information for studying mortality patterns in populations that lack reliable vital registration data. Methods for transforming verbal autopsy results into meaningful information for health workers and policymakers, however, are often costly or complicated to use. We present a simple additive algorithm, the Tariff Method (termed Tariff, which can be used for assigning individual cause of death and for determining cause-specific mortality fractions (CSMFs from verbal autopsy data. Methods Tariff calculates a score, or "tariff," for each cause, for each sign/symptom, across a pool of validated verbal autopsy data. The tariffs are summed for a given response pattern in a verbal autopsy, and this sum (score provides the basis for predicting the cause of death in a dataset. We implemented this algorithm and evaluated the method's predictive ability, both in terms of chance-corrected concordance at the individual cause assignment level and in terms of CSMF accuracy at the population level. The analysis was conducted separately for adult, child, and neonatal verbal autopsies across 500 pairs of train-test validation verbal autopsy data. Results Tariff is capable of outperforming physician-certified verbal autopsy in most cases. In terms of chance-corrected concordance, the method achieves 44.5% in adults, 39% in children, and 23.9% in neonates. CSMF accuracy was 0.745 in adults, 0.709 in children, and 0.679 in neonates. Conclusions Verbal autopsies can be an efficient means of obtaining cause of death data, and Tariff provides an intuitive, reliable method for generating individual cause assignment and CSMFs. The method is transparent and flexible and can be readily implemented by users without training in statistics or computer science.

  19. Shielding design method for LMFBR validation on the Phenix factor

    International Nuclear Information System (INIS)

    Cabrillat, J.C.; Crouzet, J.; Misrakis, J.; Salvatores, M.; Rado, V.; Palmiotti, G.

    1983-05-01

    Shielding design methods, developed at CEA for shielding calculations find a global validation by the means of Phenix power reactor (250 MWe) measurements. Particularly, the secondary sodium activation of pool type LMFBR such as Super Phenix (1200 MWe) which is subject to strict safety limitation is well calculated by the adapted scheme, i.e. a two dimension transport calculation of shielding coupled to a Monte-Carlo calculation of secondary sodium activation

  20. Determination of perfluorinated compounds in fish fillet homogenates: Method validation and application to fillet homogenates from the Mississippi River

    International Nuclear Information System (INIS)

    Malinsky, Michelle Duval; Jacoby, Cliffton B.; Reagen, William K.

    2011-01-01

    We report herein a simple protein precipitation extraction-liquid chromatography tandem mass spectrometry (LC/MS/MS) method, validation, and application for the analysis of perfluorinated carboxylic acids (C7-C12), perfluorinated sulfonic acids (C4, C6, and C8), and perfluorooctane sulfonamide (FOSA) in fish fillet tissue. The method combines a rapid homogenization and protein precipitation tissue extraction procedure using stable-isotope internal standard (IS) calibration. Method validation in bluegill (Lepomis macrochirus) fillet tissue evaluated the following: (1) method accuracy and precision in both extracted matrix-matched calibration and solvent (unextracted) calibration, (2) quantitation of mixed branched and linear isomers of perfluorooctanoate (PFOA) and perfluorooctanesulfonate (PFOS) with linear isomer calibration, (3) quantitation of low level (ppb) perfluorinated compounds (PFCs) in the presence of high level (ppm) PFOS, and (4) specificity from matrix interferences. Both calibration techniques produced method accuracy of at least 100 ± 13% with a precision (%RSD) ≤18% for all target analytes. Method accuracy and precision results for fillet samples from nine different fish species taken from the Mississippi River in 2008 and 2009 are also presented.

  1. Determination of perfluorinated compounds in fish fillet homogenates: Method validation and application to fillet homogenates from the Mississippi River

    Energy Technology Data Exchange (ETDEWEB)

    Malinsky, Michelle Duval, E-mail: mmalinsky@mmm.com [3M Environmental Laboratory, 3M Center, Building 0260-05-N-17, St. Paul, MN 55144-1000 (United States); Jacoby, Cliffton B.; Reagen, William K. [3M Environmental Laboratory, 3M Center, Building 0260-05-N-17, St. Paul, MN 55144-1000 (United States)

    2011-01-10

    We report herein a simple protein precipitation extraction-liquid chromatography tandem mass spectrometry (LC/MS/MS) method, validation, and application for the analysis of perfluorinated carboxylic acids (C7-C12), perfluorinated sulfonic acids (C4, C6, and C8), and perfluorooctane sulfonamide (FOSA) in fish fillet tissue. The method combines a rapid homogenization and protein precipitation tissue extraction procedure using stable-isotope internal standard (IS) calibration. Method validation in bluegill (Lepomis macrochirus) fillet tissue evaluated the following: (1) method accuracy and precision in both extracted matrix-matched calibration and solvent (unextracted) calibration, (2) quantitation of mixed branched and linear isomers of perfluorooctanoate (PFOA) and perfluorooctanesulfonate (PFOS) with linear isomer calibration, (3) quantitation of low level (ppb) perfluorinated compounds (PFCs) in the presence of high level (ppm) PFOS, and (4) specificity from matrix interferences. Both calibration techniques produced method accuracy of at least 100 {+-} 13% with a precision (%RSD) {<=}18% for all target analytes. Method accuracy and precision results for fillet samples from nine different fish species taken from the Mississippi River in 2008 and 2009 are also presented.

  2. Validity studies among hierarchical methods of cluster analysis using cophenetic correlation coefficient

    International Nuclear Information System (INIS)

    Carvalho, Priscilla R.; Munita, Casimiro S.; Lapolli, André L.

    2017-01-01

    The literature presents many methods for partitioning of data base, and is difficult choose which is the most suitable, since the various combinations of methods based on different measures of dissimilarity can lead to different patterns of grouping and false interpretations. Nevertheless, little effort has been expended in evaluating these methods empirically using an archaeological data base. In this way, the objective of this work is make a comparative study of the different cluster analysis methods and identify which is the most appropriate. For this, the study was carried out using a data base of the Archaeometric Studies Group from IPEN-CNEN/SP, in which 45 samples of ceramic fragments from three archaeological sites were analyzed by instrumental neutron activation analysis (INAA) which were determinate the mass fraction of 13 elements (As, Ce, Cr, Eu, Fe, Hf, La, Na, Nd, Sc, Sm, Th, U). The methods used for this study were: single linkage, complete linkage, average linkage, centroid and Ward. The validation was done using the cophenetic correlation coefficient and comparing these values the average linkage method obtained better results. A script of the statistical program R with some functions was created to obtain the cophenetic correlation. By means of these values was possible to choose the most appropriate method to be used in the data base. (author)

  3. Validity studies among hierarchical methods of cluster analysis using cophenetic correlation coefficient

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Priscilla R.; Munita, Casimiro S.; Lapolli, André L., E-mail: prii.ramos@gmail.com, E-mail: camunita@ipen.br, E-mail: alapolli@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The literature presents many methods for partitioning of data base, and is difficult choose which is the most suitable, since the various combinations of methods based on different measures of dissimilarity can lead to different patterns of grouping and false interpretations. Nevertheless, little effort has been expended in evaluating these methods empirically using an archaeological data base. In this way, the objective of this work is make a comparative study of the different cluster analysis methods and identify which is the most appropriate. For this, the study was carried out using a data base of the Archaeometric Studies Group from IPEN-CNEN/SP, in which 45 samples of ceramic fragments from three archaeological sites were analyzed by instrumental neutron activation analysis (INAA) which were determinate the mass fraction of 13 elements (As, Ce, Cr, Eu, Fe, Hf, La, Na, Nd, Sc, Sm, Th, U). The methods used for this study were: single linkage, complete linkage, average linkage, centroid and Ward. The validation was done using the cophenetic correlation coefficient and comparing these values the average linkage method obtained better results. A script of the statistical program R with some functions was created to obtain the cophenetic correlation. By means of these values was possible to choose the most appropriate method to be used in the data base. (author)

  4. Validation of a stability-indicating spectrometric method for the determination of sulfacetamide sodium in pure form and ophthalmic preparations

    Directory of Open Access Journals (Sweden)

    Sofia Ahmed

    2017-01-01

    Full Text Available Introduction: Sulfacetamide sodium is a widely used sulfonamide for ophthalmic infections. Objective: A number of analytical methods have been reported for the analysis of sulfacetamide but they lack the ability to determine both the active drug and its major degradation product, sulfanilamide, simultaneously in a sample. Materials and Methods: In the present study a simple, rapid and economical stability-indicating UV spectrometric method has been validated for the simultaneous assay of sulfacetamide sodium and sulfanilamide in pure form and in ophthalmic preparations. Results: The method has been found to be accurate (recovery 100.03 ±0.589% and precise (RSD 0.587% with detectable and quantifiable limits of 1.67×10–6 M (0.04 mg% and 5.07×10–6 M (0.13 mg%, respectively for the assay of pure sulfacetamide sodium. The method is also found to be accurate and precise to small changes in wavelength, pH and buffer concentration as well as to forced degradation. The study further includes the validation of the method for the assay of pure sulfanilamide in solution, which has been found to be accurate, precise and robust. Conclusion: The results indicate that the proposed two-component spectrometric method is stability-indicating and can be used for the simultaneous assay of both sulfacetamide sodium and sulfanilamide in synthetic mixtures and degraded solutions.

  5. Validity of a Simulation Game as a Method for History Teaching

    Science.gov (United States)

    Corbeil, Pierre; Laveault, Dany

    2011-01-01

    The aim of this research is, first, to determine the validity of a simulation game as a method of teaching and an instrument for the development of reasoning and, second, to study the relationship between learning and students' behavior toward games. The participants were college students in a History of International Relations course, with two…

  6. Method validation to measure Strontium-90 in urine sample for internal dosimetry assessment

    International Nuclear Information System (INIS)

    Bitar, A.; Maghrabi, M.; Alhamwi, A.

    2010-12-01

    Occupational individuals exposed at some scientific centers in Syrian Arab Republic to potentially significant intake by ingestion or inhalation during process of producing radiopharmaceutical compounds. The received radioactive intake differs in relation to the amount of radionuclides released during the preparation processes, to the work conditions and to the applying ways of the radiation protection procedures. TLD (Thermoluminescence Dosimeter) is usually used for external radiation monitoring for workers in radioisotope centers. During the external monitoring programme, it was noticed that some workers were exposed to high external dose resultant from radiation accident in their laboratory when preparing Y-90 from Sr-90. For internal dose assessment, chemical method to measure the amount of Sr-90 in urine samples was validated and explained in details in this study. Urine bioassays were carried out and the activities of 90 Sr were determined using liquid scintillation counter. Then, the validated method was used for internal occupational monitoring purposes through the design of internal monitoring programme. The programme was established for four workers who are dealing, twice per month, with an amount of about 20 mCi in each time. At the beginning, theoretical study was done to assess maximum risks for workers. Calculated internal doses showed that it is necessary to apply internal routine monitoring programme for those workers. (author)

  7. Quantitative determination and validation of octreotide acetate using 1 H-NMR spectroscopy with internal standard method.

    Science.gov (United States)

    Yu, Chen; Zhang, Qian; Xu, Peng-Yao; Bai, Yin; Shen, Wen-Bin; Di, Bin; Su, Meng-Xiang

    2018-01-01

    Quantitative nuclear magnetic resonance (qNMR) is a well-established technique in quantitative analysis. We presented a validated 1 H-qNMR method for assay of octreotide acetate, a kind of cyclic octopeptide. Deuterium oxide was used to remove the undesired exchangeable peaks, which was referred to as proton exchange, in order to make the quantitative signals isolated in the crowded spectrum of the peptide and ensure precise quantitative analysis. Gemcitabine hydrochloride was chosen as the suitable internal standard. Experimental conditions, including relaxation delay time, the numbers of scans, and pulse angle, were optimized first. Then method validation was carried out in terms of selectivity, stability, linearity, precision, and robustness. The assay result was compared with that by means of high performance liquid chromatography, which is provided by Chinese Pharmacopoeia. The statistical F test, Student's t test, and nonparametric test at 95% confidence level indicate that there was no significant difference between these two methods. qNMR is a simple and accurate quantitative tool with no need for specific corresponding reference standards. It has the potential of the quantitative analysis of other peptide drugs and standardization of the corresponding reference standards. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Study The Validity of The Direct Mathematical Method For Calculation The Total Efficiency Using Point And Disk Sources

    International Nuclear Information System (INIS)

    Hagag, O.M.; Nafee, S.S.; Naeem, M.A.; El Khatib, A.M.

    2011-01-01

    The direct mathematical method has been developed for calculating the total efficiency of many cylindrical gamma detectors, especially HPGe and NaI detector. Different source geometries are considered (point and disk). Further into account is taken of gamma attenuation from detector window or any interfacing absorbing layer. Results are compared with published experimental data to study the validity of the direct mathematical method to calculate total efficiency for any gamma detector size.

  9. Survey and assessment of conventional software verification and validation methods

    International Nuclear Information System (INIS)

    Miller, L.A.; Groundwater, E.; Mirsky, S.M.

    1993-04-01

    By means of a literature survey, a comprehensive set of methods was identified for the verification and validation of conventional software. The 134 methods so identified were classified according to their appropriateness for various phases of a developmental lifecycle -- requirements, design, and implementation; the last category was subdivided into two, static testing and dynamic testing methods. The methods were then characterized in terms of eight rating factors, four concerning ease-of-use of the methods and four concerning the methods' power to detect defects. Based on these factors, two measurements were developed to permit quantitative comparisons among methods, a Cost-Benefit metric and an Effectiveness Metric. The Effectiveness Metric was further refined to provide three different estimates for each method, depending on three classes of needed stringency of V ampersand V (determined by ratings of a system's complexity and required-integrity). Methods were then rank-ordered for each of the three classes in terms of their overall cost-benefits and effectiveness. The applicability was then assessed of each method for the four identified components of knowledge-based and expert systems, as well as the system as a whole

  10. In-house validation of a liquid chromatography-tandem mass spectrometry method for the determination of selective androgen receptor modulators (SARMS) in bovine urine.

    Science.gov (United States)

    Schmidt, Kathrin S; Mankertz, Joachim

    2018-06-01

    A sensitive and robust LC-MS/MS method allowing the rapid screening and confirmation of selective androgen receptor modulators in bovine urine was developed and successfully validated according to Commission Decision 2002/657/EC, chapter 3.1.3 'alternative validation', by applying a matrix-comprehensive in-house validation concept. The confirmation of the analytes in the validation samples was achieved both on the basis of the MRM ion ratios as laid down in Commission Decision 2002/657/EC and by comparison of their enhanced product ion (EPI) spectra with a reference mass spectral library by making use of the QTRAP technology. Here, in addition to the MRM survey scan, EPI spectra were generated in a data-dependent way according to an information-dependent acquisition criterion. Moreover, stability studies of the analytes in solution and in matrix according to an isochronous approach proved the stability of the analytes in solution and in matrix for at least the duration of the validation study. To identify factors that have a significant influence on the test method in routine analysis, a factorial effect analysis was performed. To this end, factors considered to be relevant for the method in routine analysis (e.g. operator, storage duration of the extracts before measurement, different cartridge lots and different hydrolysis conditions) were systematically varied on two levels. The examination of the extent to which these factors influence the measurement results of the individual analytes showed that none of the validation factors exerts a significant influence on the measurement results.

  11. Evaluating the Social Validity of the Early Start Denver Model: A Convergent Mixed Methods Study

    Science.gov (United States)

    Ogilvie, Emily; McCrudden, Matthew T.

    2017-01-01

    An intervention has social validity to the extent that it is socially acceptable to participants and stakeholders. This pilot convergent mixed methods study evaluated parents' perceptions of the social validity of the Early Start Denver Model (ESDM), a naturalistic behavioral intervention for children with autism. It focused on whether the parents…

  12. Validation of the quality control methods for active ingredients of Fungirex cream

    International Nuclear Information System (INIS)

    Perez Navarro, Maikel; Rodriguez Hernandez, Yaslenis; Suarez Perez, Yania

    2014-01-01

    Fungirex cream is a two-drug product, that is, undecylenic acid and zinc undecylenate over a suitable basis. Since this is a product not documented in the official monographs of the pharmacopoeia, simple analytical methods were suggested for quantitation of analytes of interest in the cream, which are useful for release of newly prepared cream batches. To validate two volumetric methods for the quality control of active ingredients in Fungirex cream

  13. General criteria for validation of dosimetry methods in the context of a quality system ISO / IEC 17025

    International Nuclear Information System (INIS)

    Martin Garcia, R.; Navarro Bravo, T.

    2011-01-01

    The accreditation of a testing laboratory in accordance with ISO / IEC 17025 recognizes the technical competence of a laboratory to perform certain tests. One of the requirements of that rule states that laboratories must demonstrate that the methods used are valid and appropriate for the intended use and customer needs. This demonstration is accomplished through the process of validation of methods, defined in the rule it self as c onfirmation by examination and provision of objective evidence that the requirements for a particular purpose . The process of validating a test method should be well planned and documented, including the requirements under the applicable rules and criteria established by the laboratory to comply with these requirements.

  14. Development and Validation of an LC-MS/MS Method and Comparison with a GC-MS Method to Measure Phenytoin in Human Brain Dialysate, Blood, and Saliva

    Directory of Open Access Journals (Sweden)

    Raphael Hösli

    2018-01-01

    Full Text Available Phenytoin (PHT is one of the most often used critical dose drugs, where insufficient or excessive dosing can have severe consequences such as seizures or toxicity. Thus, the monitoring and precise measuring of PHT concentrations in patients is crucial. This study develops and validates an LC-MS/MS method for the measurement of phenytoin concentrations in different body compartments (i.e., human brain dialysate, blood, and saliva and compares it with a formerly developed GC-MS method that measures PHT in the same biological matrices. The two methods are evaluated and compared based on their analytical performance, appropriateness to analyze human biological samples, including corresponding extraction and cleanup procedures, and their validation according to ISO 17025/FDA Guidance for Industry. The LC-MS/MS method showed a higher performance compared with the GC-MS method. The LC-MS/MS was more sensitive, needed a smaller sample volume (25 µL and less chemicals, was less time consuming (cleaning up, sample preparation, and analysis, and resulted in a better LOD ( 0.995 for all tested matrices (blood, saliva, and dialysate. For larger sample numbers as in pharmacokinetic/pharmacodynamic studies and for bedside as well as routine analyses, the LC-MS/MS method offers significant advantages over the GC-MS method.

  15. Vitamin D status assessed by a validated HPLC method: within and between variation in subjects supplemented with vitamin D3

    DEFF Research Database (Denmark)

    Jakobsen, Jette; Bysted, Anette; Andersen, Rikke

    2009-01-01

    Objective. The aim of this study was to develop and validate a high-pressure liquid chromatography (HPLC) method for assessing vitamin D status as 25-hydroxyvitamin D2 (S-25OHD2) and 25-hydroxyvitamin D3 (S-25OHD3) in serum. Material and methods. We assessed the within- and between-subject variat......Objective. The aim of this study was to develop and validate a high-pressure liquid chromatography (HPLC) method for assessing vitamin D status as 25-hydroxyvitamin D2 (S-25OHD2) and 25-hydroxyvitamin D3 (S-25OHD3) in serum. Material and methods. We assessed the within- and between......-subject variation of vitamin D status in serum samples from four different dietary intervention studies in which subjects (n=92) were supplemented with different doses of vitamin D3 (5-12 g/day) and for different durations (4-20 months). Results. The HPLC method was applicable for 4.0-200 nmol S-25OHD/L, while...... the within-day and between-days variations were 3.8 % and 5.7 %, respectively. There was a concentration-dependent difference between results obtained by a commercial radioimmunoassay and results from the HPLC method of -5 to 20 nmol 25OHD/L in the range 10-100 nmol 25OHD/L. The between-subject variation...

  16. Determination of polychlorinated dibenzodioxins and polychlorinated dibenzofurans (PCDDs/PCDFs) in food and feed using a bioassay. Result of a validation study

    Energy Technology Data Exchange (ETDEWEB)

    Gizzi, G.; Holst, C. von; Anklam, E. [Commission of the European Communities, Geel (Belgium). Joint Research Centre, Inst. for Reference Materials and Measurement, Food Safety and Quality Unit; Hoogenboom, R. [RIKILT-Intitute of Food Safety, Wageningen (Netherlands); Rose, M. [Defra Central Science Laboratory, Sand Hutton, York (United Kingdom)

    2004-09-15

    It is estimated that more than 90% of dioxins consumed by humans come from foods derived from animals. The European Commission through a Council Regulation (No 2375/2001) and a Directive (2001/102/EC), both revised by the Commission Recommendation (2002/201/EC), has set maximum levels for dioxins in food and feedstuffs. To implement the regulation, dioxin-monitoring programs of food and feedstuffs will be undertaken by the Member States requiring the analysis of large amounts of samples. Food and feed companies will have to control their products before putting them into the market. The monitoring for the presence of dioxins in food and feeds needs fast and cheap screening methods in order to select samples with potentially high levels of dioxins to be then analysed by a confirmatory method like HRGC/HRMS. Bioassays like the DR CALUX {sup registered} - assay have claimed to provide a suitable alternative for the screening of large number of samples, reducing costs and the required time of analysis. These methods have to comply with the specific characteristics considered into two Commission Directives (2002/69/EC; 2002/70/EC), establishing the requirements for the determination of dioxin and dioxin-like PCBs for the official control of food and feedstuffs. The European Commission's Joint Research Centre is pursuing validation of alternative techniques in food and feed materials. In order to evaluate the applicability of the DR CALUX {sup registered} technique as screening method in compliance with the Commission Directives, a validation study was organised in collaboration with CSL and RIKILT. The aim of validating an analytical method is first to determine its performance characteristics (e.g. variability, bias, rate of false positive and false negative results), and secondly to evaluate if the method is fit for the purpose. Two approaches are commonly used: an in-house validation is preferentially performed first in order to establish whether the method is

  17. Novel and validated titrimetric method for determination of selected angiotensin-II-receptor antagonists in pharmaceutical preparations and its comparison with UV spectrophotometric determination

    Directory of Open Access Journals (Sweden)

    Shrikant H. Patil

    2012-12-01

    Full Text Available A novel and simple titrimetric method for determination of commonly used angiotensin-II-receptor antagonists (ARA-IIs is developed and validated. The direct acid base titration of four ARA-IIs, namely eprosartan mesylate, irbesartan, telmisartan and valsartan, was carried out in the mixture of ethanol:water (1:1 as solvent using standardized sodium hydroxide aqueous solution as titrant, either visually using phenolphthalein as an indicator or potentiometrically using combined pH electrode. The method was found to be accurate and precise, having relative standard deviation of less than 2% for all ARA-IIs studied. Also, it was shown that the method could be successfully applied to the assay of commercial pharmaceuticals containing the above-mentioned ARA-IIs. The validity of the method was tested by the recovery studies of standard addition to pharmaceuticals and the results were found to be satisfactory. Results obtained by this method were found to be in good agreement with those obtained by UV spectrophotometric method. For UV spectrophotometric analysis ethanol was used as a solvent and wavelength of 233 nm, 246 nm, 296 nm, and 250 nm was selected for determination of eprosartan mesylate, irbesartan, telmisartan, and valsartan respectively. The proposed titrimetric method is simple, rapid, convenient and sufficiently precise for quality control purposes. Keywords: Angiotensin-II-receptor antagonists, Titrimetric assay, UV spectrophotometry, Validation

  18. Validation of an open-formula, diagnostic real-time PCR method for 20-hr detection of Salmonella in animal feeds

    DEFF Research Database (Denmark)

    Löfström, Charlotta; Hoorfar, Jeffrey

    2012-01-01

    A comparative study of a 20-hr, non-commercial, open-formula PCR method and the standard culture-based method NMKL 187, for detection of Salmonella, was performed according to the validation protocol from the Nordic organization for validation of alternative microbiological methods (NordVal) on 81...

  19. Validation of different spectrophotometric methods for determination of vildagliptin and metformin in binary mixture

    Science.gov (United States)

    Abdel-Ghany, Maha F.; Abdel-Aziz, Omar; Ayad, Miriam F.; Tadros, Mariam M.

    New, simple, specific, accurate, precise and reproducible spectrophotometric methods have been developed and subsequently validated for determination of vildagliptin (VLG) and metformin (MET) in binary mixture. Zero order spectrophotometric method was the first method used for determination of MET in the range of 2-12 μg mL-1 by measuring the absorbance at 237.6 nm. The second method was derivative spectrophotometric technique; utilized for determination of MET at 247.4 nm, in the range of 1-12 μg mL-1. Derivative ratio spectrophotometric method was the third technique; used for determination of VLG in the range of 4-24 μg mL-1 at 265.8 nm. Fourth and fifth methods adopted for determination of VLG in the range of 4-24 μg mL-1; were ratio subtraction and mean centering spectrophotometric methods, respectively. All the results were statistically compared with the reported methods, using one-way analysis of variance (ANOVA). The developed methods were satisfactorily applied to analysis of the investigated drugs and proved to be specific and accurate for quality control of them in pharmaceutical dosage forms.

  20. Method validation and stability study of quercetin in topical emulsions

    Directory of Open Access Journals (Sweden)

    Rúbia Casagrande

    2009-01-01

    Full Text Available This study validated a high performance liquid chromatography (HPLC method for the quantitative evaluation of quercetin in topical emulsions. The method was linear within 0.05 - 200 μg/mL range with a correlation coefficient of 0.9997, and without interference in the quercetin peak. The detection and quantitation limits were 18 and 29 ng/mL, respectively. The intra- and inter-assay precisions presented R.S.D. values lower than 2%. An average of 93% and 94% of quercetin was recovered for non-ionic and anionic emulsions, respectively. The raw material and anionic emulsion, but not non-ionic emulsion, were stable in all storage conditions for one year. The method reported is a fast and reliable HPLC technique useful for quercetin determination in topical emulsions.

  1. A Validated RP-HPLC Method for the Determination of Atazanavir in Pharmaceutical Dosage Form

    Directory of Open Access Journals (Sweden)

    K. Srinivasu

    2011-01-01

    Full Text Available A validated RP HPLC method for the estimation of atazanavir in capsule dosage form on YMC ODS 150 × 4.6 mm, 5 μ column using mobile phase composition of ammonium dihydrogen phosphate buffer (pH 2.5 with acetonitrile (55:45 v/v. Flow rate was maintained at 1.5 mL/min with 288 nm UV detection. The retention time obtained for atazanavir was at 4.7 min. The detector response was linear in the concentration range of 30 - 600 μg/mL. This method has been validated and shown to be specific, sensitive, precise, linear, accurate, rugged, robust and fast. Hence, this method can be applied for routine quality control of atazanavir in capsule dosage forms as well as in bulk drug.

  2. Validation Study on a Rapid Method for Simultaneous Determination of Pesticide Residues in Vegetables and Fruits by LC-MS/MS.

    Science.gov (United States)

    Sato, Tamaki; Miyamoto, Iori; Uemura, Masako; Nakatani, Tadashi; Kakutani, Naoya; Yamano, Tetsuo

    2016-01-01

    A validation study was carried out on a rapid method for the simultaneous determination of pesticide residues in vegetables and fruits by LC-MS/MS. Preparation of the test solution was performed by a solid-phase extraction technique with QuEChERS (STQ method). Pesticide residues were extracted with acetonitrile using a homogenizer, followed by salting-out and dehydration at the same time. The acetonitrile layer was purified with C18 and PSA mini-columns. The method was assessed for 130 pesticide residues in 14 kinds of vegetables and fruits at the concentration level of 0.01 μg/g according to the method validation guideline of the Ministry of Health, Labour and Welfare of Japan. As a result 75 to 120 pesticide residues were determined satisfactorily in the tested samples. Thus, this method could be useful for a rapid and simultaneous determination of multi-class pesticide residues in various vegetables and fruits.

  3. A Sensitive Validated Spectrophotometric Method for the Determination of Flucloxacillin Sodium

    Directory of Open Access Journals (Sweden)

    R. Singh Gujral

    2009-01-01

    Full Text Available A simple and sensitive spectrophotometric method has been proposed for the determination of flucloxacillin sodium. The determination method is based on charge transfer complexation reaction of the drug with iodine in methanol-dichloromethane medium. The absorbance was measured at 362 nm against the reagent blank. Under optimized experimental conditions, Beer's law is obeyed in the concentration ranges 1-9 μg/mL for flucloxacillin. The method was validated for specificity, linearity, precision, accuracy. The degree of linearity of the calibration curves, the percent recoveries, limit of detection and quantitation for the spectrophotometric method were determined. No interferences could be observed from the additives commonly present in the pharmaceutical formulations. The method was successfully applied for in vitro determination of human urine samples with low RSD value. This is simple, specific, accurate and sensitive spectrophotometric method.

  4. Validation of a Smartphone Image-Based Dietary Assessment Method for Pregnant Women

    Directory of Open Access Journals (Sweden)

    Amy M. Ashman

    2017-01-01

    Full Text Available Image-based dietary records could lower participant burden associated with traditional prospective methods of dietary assessment. They have been used in children, adolescents and adults, but have not been evaluated in pregnant women. The current study evaluated relative validity of the DietBytes image-based dietary assessment method for assessing energy and nutrient intakes. Pregnant women collected image-based dietary records (via a smartphone application of all food, drinks and supplements consumed over three non-consecutive days. Intakes from the image-based method were compared to intakes collected from three 24-h recalls, taken on random days; once per week, in the weeks following the image-based record. Data were analyzed using nutrient analysis software. Agreement between methods was ascertained using Pearson correlations and Bland-Altman plots. Twenty-five women (27 recruited, one withdrew, one incomplete, median age 29 years, 15 primiparas, eight Aboriginal Australians, completed image-based records for analysis. Significant correlations between the two methods were observed for energy, macronutrients and fiber (r = 0.58–0.84, all p < 0.05, and for micronutrients both including (r = 0.47–0.94, all p < 0.05 and excluding (r = 0.40–0.85, all p < 0.05 supplements in the analysis. Bland-Altman plots confirmed acceptable agreement with no systematic bias. The DietBytes method demonstrated acceptable relative validity for assessment of nutrient intakes of pregnant women.

  5. Using method triangulation to validate a new instrument (CPWQ-com) assessing cancer patients' satisfaction with communication

    DEFF Research Database (Denmark)

    Ross, Lone; Lundstrøm, Louise Hyldborg; Petersen, Morten Aagaard

    2012-01-01

    Patients' perceptions of care including the communication with health care staff is recognized as an important aspect of the quality of cancer care. Using mixed methods, we developed and validated a short instrument assessing this communication.......Patients' perceptions of care including the communication with health care staff is recognized as an important aspect of the quality of cancer care. Using mixed methods, we developed and validated a short instrument assessing this communication....

  6. A validated Fourier transform infrared spectroscopy method for quantification of total lactones in Inula racemosa and Andrographis paniculata.

    Science.gov (United States)

    Shivali, Garg; Praful, Lahorkar; Vijay, Gadgil

    2012-01-01

    Fourier transform infrared (FT-IR) spectroscopy is a technique widely used for detection and quantification of various chemical moieties. This paper describes the use of the FT-IR spectroscopy technique for the quantification of total lactones present in Inula racemosa and Andrographis paniculata. To validate the FT-IR spectroscopy method for quantification of total lactones in I. racemosa and A. paniculata. Dried and powdered I. racemosa roots and A. paniculata plant were extracted with ethanol and dried to remove ethanol completely. The ethanol extract was analysed in a KBr pellet by FT-IR spectroscopy. The FT-IR spectroscopy method was validated and compared with a known spectrophotometric method for quantification of lactones in A. paniculata. By FT-IR spectroscopy, the amount of total lactones was found to be 2.12 ± 0.47% (n = 3) in I. racemosa and 8.65 ± 0.51% (n = 3) in A. paniculata. The method showed comparable results with a known spectrophotometric method used for quantification of such lactones: 8.42 ± 0.36% (n = 3) in A. paniculata. Limits of detection and quantification for isoallantolactone were 1 µg and 10 µg respectively; for andrographolide they were 1.5 µg and 15 µg respectively. Recoveries were over 98%, with good intra- and interday repeatability: RSD ≤ 2%. The FT-IR spectroscopy method proved linear, accurate, precise and specific, with low limits of detection and quantification, for estimation of total lactones, and is less tedious than the UV spectrophotometric method for the compounds tested. This validated FT-IR spectroscopy method is readily applicable for the quality control of I. racemosa and A. paniculata. Copyright © 2011 John Wiley & Sons, Ltd.

  7. A gradient-based method for segmenting FDG-PET images: methodology and validation

    International Nuclear Information System (INIS)

    Geets, Xavier; Lee, John A.; Gregoire, Vincent; Bol, Anne; Lonneux, Max

    2007-01-01

    A new gradient-based method for segmenting FDG-PET images is described and validated. The proposed method relies on the watershed transform and hierarchical cluster analysis. To allow a better estimation of the gradient intensity, iteratively reconstructed images were first denoised and deblurred with an edge-preserving filter and a constrained iterative deconvolution algorithm. Validation was first performed on computer-generated 3D phantoms containing spheres, then on a real cylindrical Lucite phantom containing spheres of different volumes ranging from 2.1 to 92.9 ml. Moreover, laryngeal tumours from seven patients were segmented on PET images acquired before laryngectomy by the gradient-based method and the thresholding method based on the source-to-background ratio developed by Daisne (Radiother Oncol 2003;69:247-50). For the spheres, the calculated volumes and radii were compared with the known values; for laryngeal tumours, the volumes were compared with the macroscopic specimens. Volume mismatches were also analysed. On computer-generated phantoms, the deconvolution algorithm decreased the mis-estimate of volumes and radii. For the Lucite phantom, the gradient-based method led to a slight underestimation of sphere volumes (by 10-20%), corresponding to negligible radius differences (0.5-1.1 mm); for laryngeal tumours, the segmented volumes by the gradient-based method agreed with those delineated on the macroscopic specimens, whereas the threshold-based method overestimated the true volume by 68% (p = 0.014). Lastly, macroscopic laryngeal specimens were totally encompassed by neither the threshold-based nor the gradient-based volumes. The gradient-based segmentation method applied on denoised and deblurred images proved to be more accurate than the source-to-background ratio method. (orig.)

  8. Validity of a structured method of selecting abstracts for a plastic surgical scientific meeting

    NARCIS (Netherlands)

    van der Steen, LPE; Hage, JJ; Kon, M; Monstrey, SJ

    In 1999, the European Association of Plastic Surgeons accepted a structured method to assess and select the abstracts that are submitted for its yearly scientific meeting. The two criteria used to evaluate whether such a selection method is accurate were reliability and validity. The authors

  9. Clinical assessment of the physical activity pattern of chronic fatigue syndrome patients: a validation of three methods

    Directory of Open Access Journals (Sweden)

    Meer van der Jos

    2009-04-01

    Full Text Available Abstract Background Effective treatment of chronic fatigue syndrome (CFS with cognitive behavioural therapy (CBT relies on a correct classification of so called 'fluctuating active' versus 'passive' patients. For successful treatment with CBT is it especially important to recognise the passive patients and give them a tailored treatment protocol. In the present study it was evaluated whether CFS patient's physical activity pattern can be assessed most accurately with the 'Activity Pattern Interview' (API, the International Physical Activity Questionnaire (IPAQ or the CFS-Activity Questionnaire (CFS-AQ. Methods The three instruments were validated compared to actometers. Actometers are until now the best and most objective instrument to measure physical activity, but they are too expensive and time consuming for most clinical practice settings. In total 226 CFS patients enrolled for CBT therapy answered the API at intake and filled in the two questionnaires. Directly after intake they wore the actometer for two weeks. Based on receiver operating characteristic (ROC curves the validity of the three methods were assessed and compared. Results Both the API and the two questionnaires had an acceptable validity (0.64 to 0.71. None of the three instruments was significantly better than the others. The proportion of false predictions was rather high for all three instrument. The IPAQ had the highest proportion of correct passive predictions (sensitivity 70.1%. Conclusion The validity of all three instruments appeared to be fair, and all showed rather high proportions of false classifications. Hence in fact none of the tested instruments could really be called satisfactory. Because the IPAQ showed to be the best in correctly predicting 'passive' CFS patients, which is most essentially related to treatment results, it was concluded that the IPAQ is the preferable alternative for an actometer when treating CFS patients in clinical practice.

  10. Validation of the intrinsic spatial efficiency method for non cylindrical homogeneous sources using MC simulation

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz-Ramírez, Pablo, E-mail: rapeitor@ug.uchile.cl; Ruiz, Andrés [Departamento de Física, Facultad de Ciencias, Universidad de Chile (Chile)

    2016-07-07

    The Monte Carlo simulation of the gamma spectroscopy systems is a common practice in these days. The most popular softwares to do this are MCNP and Geant4 codes. The intrinsic spatial efficiency method is a general and absolute method to determine the absolute efficiency of a spectroscopy system for any extended sources, but this was only demonstrated experimentally for cylindrical sources. Due to the difficulty that the preparation of sources with any shape represents, the simplest way to do this is by the simulation of the spectroscopy system and the source. In this work we present the validation of the intrinsic spatial efficiency method for sources with different geometries and for photons with an energy of 661.65 keV. In the simulation the matrix effects (the auto-attenuation effect) are not considered, therefore these results are only preliminaries. The MC simulation is carried out using the FLUKA code and the absolute efficiency of the detector is determined using two methods: the statistical count of Full Energy Peak (FEP) area (traditional method) and the intrinsic spatial efficiency method. The obtained results show total agreement between the absolute efficiencies determined by the traditional method and the intrinsic spatial efficiency method. The relative bias is lesser than 1% in all cases.

  11. Validated, Ultra Violet Spectroscopy method for the Dissolution study of Mycophenolate mofetil immediate release 500mg tablets

    OpenAIRE

    Surajpal P. Verma; Ozair Alam; Pooja Mullick; Nadeem Siddiqui; Suroor A. Khan

    2008-01-01

    A simple, selective and precise dissolution method was developed and validated for the Mycophenolate mofetil immediate release tablets. The method employed dissolution medium 0.1N HCl (pH1.2) and volume 900ml with USP-II apparatus (Paddle). Detection was made by measuring the absorbance on UV at the [lambda]~max~ 250nm. The method show the linearity in the range of conc. 5[micro]g/ml to 40[micro]g/ml with r^2^=0.999. The method is also validated as per International Conference of Harmonizatio...

  12. Further Validation of a Rapid Screening Semiquantitative Thin-Layer Chromatographic Method for Marketed Antimalarial Medicines for Adoption in Malawi

    Directory of Open Access Journals (Sweden)

    Dorcas Osei-Safo

    2018-01-01

    Full Text Available A recently developed semiquantitative thin-layer chromatographic (SQ-TLC assay has been employed in postmarketing surveillance of antimalarial medicines used in Malawi prior to HPLC assay. Both methods gave analogous results in a significant majority of the samples, with a good correlation (r = 0.9012 for the active pharmaceutical ingredients of the dosage forms assayed. Artemether-containing medicines had the highest percentage (92.67% of samples with comparable results for both assays. The lowest percentage (66.67% was observed in artesunate-containing medicines. The SQ-TLC method was validated for specificity, accuracy, precision, linearity, and stability according to the International Conference on Harmonisation guidelines, with the results falling within acceptable limits. For specificity, retention factor values of the test samples and reference standards were comparable, while accuracy and precision of 91.1 ± 5.7% were obtained for all samples. The method was linear in the range 1.0–2.0 µg/spot with a correlation coefficient of r = 0.9783. Stability tests also fell within acceptable limits. In this study, we present the validation of the SQ-TLC method and propose its adoption as a rapid screening tool for field estimation of the quality of antimalarial and other essential medicines in Malawi and other parts of the developing world prior to a more accurate HPLC assay.

  13. Partition method and experimental validation for impact dynamics of flexible multibody system

    Science.gov (United States)

    Wang, J. Y.; Liu, Z. Y.; Hong, J. Z.

    2018-06-01

    The impact problem of a flexible multibody system is a non-smooth, high-transient, and strong-nonlinear dynamic process with variable boundary. How to model the contact/impact process accurately and efficiently is one of the main difficulties in many engineering applications. The numerical approaches being used widely in impact analysis are mainly from two fields: multibody system dynamics (MBS) and computational solid mechanics (CSM). Approaches based on MBS provide a more efficient yet less accurate analysis of the contact/impact problems, while approaches based on CSM are well suited for particularly high accuracy needs, yet require very high computational effort. To bridge the gap between accuracy and efficiency in the dynamic simulation of a flexible multibody system with contacts/impacts, a partition method is presented considering that the contact body is divided into two parts, an impact region and a non-impact region. The impact region is modeled using the finite element method to guarantee the local accuracy, while the non-impact region is modeled using the modal reduction approach to raise the global efficiency. A three-dimensional rod-plate impact experiment is designed and performed to validate the numerical results. The principle for how to partition the contact bodies is proposed: the maximum radius of the impact region can be estimated by an analytical method, and the modal truncation orders of the non-impact region can be estimated by the highest frequency of the signal measured. The simulation results using the presented method are in good agreement with the experimental results. It shows that this method is an effective formulation considering both accuracy and efficiency. Moreover, a more complicated multibody impact problem of a crank slider mechanism is investigated to strengthen this conclusion.

  14. Validation of an electrophoretic method to detect albuminuria in cats.

    Science.gov (United States)

    Ferlizza, Enea; Dondi, Francesco; Andreani, Giulia; Bucci, Diego; Archer, Joy; Isani, Gloria

    2017-08-01

    Objectives The aims of this study were to validate a semi-automated high-resolution electrophoretic technique to quantify urinary albumin in healthy and diseased cats, and to evaluate its diagnostic performance in cases of proteinuria and renal diseases. Methods Urine samples were collected from 88 cats (healthy; chronic kidney disease [CKD]; lower urinary tract disease [LUTD]; non-urinary tract diseases [OTHER]). Urine samples were routinely analysed and high-resolution electrophoresis (HRE) was performed. Within-assay and between-assay variability, linearity, accuracy, recovery and the lowest detectable and quantifiable bands were calculated. Receiver operating curve (ROC) analysis was also performed. Results All coefficients of variation were HRE allowed the visualisation of a faint band of albumin and a diffused band between alpha and beta zones in healthy cats, while profiles from diseased cats were variable. Albumin (mg/dl) and urine albumin:creatinine ratio (UAC) were significantly ( P HRE is an accurate and precise method that could be used to measure albuminuria in cats. UAC was useful to correctly classify proteinuria and to discriminate between healthy and diseased cats. HRE might also provide additional information on urine proteins with a profile of all proteins (albumin and globulins) to aid clinicians in the diagnosis of diseases characterised by proteinuria.

  15. Quantifying the measurement uncertainty of results from environmental analytical methods.

    Science.gov (United States)

    Moser, J; Wegscheider, W; Sperka-Gottlieb, C

    2001-07-01

    The Eurachem-CITAC Guide Quantifying Uncertainty in Analytical Measurement was put into practice in a public laboratory devoted to environmental analytical measurements. In doing so due regard was given to the provisions of ISO 17025 and an attempt was made to base the entire estimation of measurement uncertainty on available data from the literature or from previously performed validation studies. Most environmental analytical procedures laid down in national or international standards are the result of cooperative efforts and put into effect as part of a compromise between all parties involved, public and private, that also encompasses environmental standards and statutory limits. Central to many procedures is the focus on the measurement of environmental effects rather than on individual chemical species. In this situation it is particularly important to understand the measurement process well enough to produce a realistic uncertainty statement. Environmental analytical methods will be examined as far as necessary, but reference will also be made to analytical methods in general and to physical measurement methods where appropriate. This paper describes ways and means of quantifying uncertainty for frequently practised methods of environmental analysis. It will be shown that operationally defined measurands are no obstacle to the estimation process as described in the Eurachem/CITAC Guide if it is accepted that the dominating component of uncertainty comes from the actual practice of the method as a reproducibility standard deviation.

  16. Validation of the Nuclear Design Method for MOX Fuel Loaded LWR Cores

    International Nuclear Information System (INIS)

    Saji, E.; Inoue, Y.; Mori, M.; Ushio, T.

    2001-01-01

    The actual batch loading of mixed-oxide (MOX) fuel in light water reactors (LWRs) is now ready to start in Japan. One of the efforts that have been devoted to realizing this batch loading has been validation of the nuclear design methods calculating the MOX-fuel-loaded LWR core characteristics. This paper summarizes the validation work for the applicability of the CASMO-4/SIMULATE-3 in-core fuel management code system to MOX-fuel-loaded LWR cores. This code system is widely used by a number of electric power companies for the core management of their commercial LWRs. The validation work was performed for both boiling water reactor (BWR) and pressurized water reactor (PWR) applications. Each validation consists of two parts: analyses of critical experiments and core tracking calculations of operating plants. For the critical experiments, we have chosen a series of experiments known as the VENUS International Program (VIP), which was performed at the SCK/CEN MOL laboratory in Belgium. VIP consists of both BWR and PWR fuel assembly configurations. As for the core tracking calculations, the operating data of MOX-fuel-loaded BWR and PWR cores in Europe have been utilized

  17. Lesion insertion in the projection domain: Methods and initial results.

    Science.gov (United States)

    Chen, Baiyu; Leng, Shuai; Yu, Lifeng; Yu, Zhicong; Ma, Chi; McCollough, Cynthia

    2015-12-01

    phantom in terms of Hounsfield unit and high-contrast resolution. For the validation of the lesion realism, lesions of various types were successfully inserted, including well circumscribed and invasive lesions, homogeneous and heterogeneous lesions, high-contrast and low-contrast lesions, isolated and vessel-attached lesions, and small and large lesions. The two experienced radiologists who reviewed the original and inserted lesions could not identify the lesions that were inserted. The same lesion, when inserted into the projection domain and reconstructed with different parameters, demonstrated a parameter-dependent appearance. A framework has been developed for projection-domain insertion of lesions into commercial CT images, which can be potentially expanded to all geometries of CT scanners. Compared to conventional image-domain methods, the authors' method reflected the impact of scan and reconstruction parameters on lesion appearance. Compared to prior projection-domain methods, the authors' method has the potential to achieve higher anatomical complexity by employing clinical patient projections and real patient lesions.

  18. HPLC method validation for modernization of the tetracycline hydrochloride capsule USP monograph

    Directory of Open Access Journals (Sweden)

    Emad M. Hussien

    2014-12-01

    Full Text Available This paper is a continuation to our previous work aiming at development and validation of a reversed-phase HPLC for modernization of tetracycline-related USP monographs and the USP general chapter . Previous results showed that the method is accurate and precise for the assay of tetracycline hydrochloride and the limit of 4-epianhydrotetracycline impurity in the drug substance and oral suspension monographs. The aim of the current paper is to examine the feasibility of the method for modernization of USP tetracycline hydrochloride capsule monograph. Specificity, linearity, accuracy and precision were examined for tetracycline hydrochloride assay and 4-epianhydrotetracycline limit. The method was linear in the concentration range from 80% to 160% (r>0.9998 of the assay concentration (0.1 mg/mL for tetracycline hydrochloride and from 50% to 150% (r>0.997 of the acceptance criteria specified in tetracycline hydrochloride capsule monograph for 4-epianhydrotetracycline (NMT 3.0%. The recovery at three concentration levels for tetracycline hydrochloride assay was between 99% and 101% and the RSD from six preparations at the concentration 0.1 mg/mL is less than 0.6%. The recovery for 4-epianhydrotetracycline limit procedure over the concentration range from 50% to 150% is between 96% and 102% with RSD less than 5%. The results met the specified acceptance criteria.

  19. Literature research concerning alternative methods for validation of criticality calculation systems

    International Nuclear Information System (INIS)

    Behler, Matthias

    2016-05-01

    Beside radiochemical analysis of irradiated fuel and critical experiments, which has become a well-established basis for the validation of depletion code and criticality codes respectively, also results of oscillation experiments or the operating conditions of power reactor and research reactors can provide useful information for the validation of the above mentioned codes. Based on a literature review the potential of the utilization of oscillation experiment measurements for the validation of criticality codes is estimated. It is found that the reactivity measurements for actinides and fission products within the CERES program on the reactors DIMPLE (Winfrith, UK) and MINERVE (Cadarache, France) can give a valuable addition to the commonly used critical experiments for criticality code validation. However, there are approaches but yet no generally satisfactory solution for integrating the reactivity measurements in a quantitative bias determination for the neutron multiplication factor of typical application cases including irradiated spent fuel outside reactor cores, calculated using common criticality codes.

  20. Examination of packaging materials in bakery products : a validated method for detection and quantification

    NARCIS (Netherlands)

    Raamsdonk, van L.W.D.; Pinckaers, V.G.Z.; Vliege, J.J.M.; Egmond, van H.J.

    2012-01-01

    Methods for the detection and quantification of packaging materials are necessary for the control of the prohibition of these materials according to Regulation (EC)767/2009. A method has been developed and validated at RIKILT for bakery products, including sweet bread and raisin bread. This choice

  1. Investigation of error estimation method of observational data and comparison method between numerical and observational results toward V and V of seismic simulation

    International Nuclear Information System (INIS)

    Suzuki, Yoshio; Kawakami, Yoshiaki; Nakajima, Norihiro

    2017-01-01

    The method to estimate errors included in observational data and the method to compare numerical results with observational results are investigated toward the verification and validation (V and V) of a seismic simulation. For the method to estimate errors, 144 literatures for the past 5 years (from the year 2010 to 2014) in the structure engineering field and earthquake engineering field where the description about acceleration data is frequent are surveyed. As a result, it is found that some processes to remove components regarded as errors from observational data are used in about 30% of those literatures. Errors are caused by the resolution, the linearity, the temperature coefficient for sensitivity, the temperature coefficient for zero shift, the transverse sensitivity, the seismometer property, the aliasing, and so on. Those processes can be exploited to estimate errors individually. For the method to compare numerical results with observational results, public materials of ASME V and V Symposium 2012-2015, their references, and above 144 literatures are surveyed. As a result, it is found that six methods have been mainly proposed in existing researches. Evaluating those methods using nine items, advantages and disadvantages for those methods are arranged. The method is not well established so that it is necessary to employ those methods by compensating disadvantages and/or to search for a solution to a novel method. (author)

  2. Chemical analysis of solid residue from liquid and solid fuel combustion: Method development and validation

    Energy Technology Data Exchange (ETDEWEB)

    Trkmic, M. [University of Zagreb, Faculty of Mechanical Engineering and Naval Architecturek Zagreb (Croatia); Curkovic, L. [University of Zagreb, Faculty of Chemical Engineering and Technology, Zagreb (Croatia); Asperger, D. [HEP-Proizvodnja, Thermal Power Plant Department, Zagreb (Croatia)

    2012-06-15

    This paper deals with the development and validation of methods for identifying the composition of solid residue after liquid and solid fuel combustion in thermal power plant furnaces. The methods were developed for energy dispersive X-ray fluorescence (EDXRF) spectrometer analysis. Due to the fuels used, the different composition and the location of creation of solid residue, it was necessary to develop two methods. The first method is used for identifying solid residue composition after fuel oil combustion (Method 1), while the second method is used for identifying solid residue composition after the combustion of solid fuels, i. e. coal (Method 2). Method calibration was performed on sets of 12 (Method 1) and 6 (Method 2) certified reference materials (CRM). CRMs and analysis test samples were prepared in pellet form using hydraulic press. For the purpose of method validation the linearity, accuracy, precision and specificity were determined, and the measurement uncertainty of methods for each analyte separately was assessed. The methods were applied in the analysis of real furnace residue samples. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  3. Bridging the Gap Between Validation and Implementation of Non-Animal Veterinary Vaccine Potency Testing Methods

    Directory of Open Access Journals (Sweden)

    Alistair Currie

    2011-11-01

    Full Text Available In recent years, technologically advanced high-throughput techniques have been developed that replace, reduce or refine animal use in vaccine quality control tests. Following validation, these tests are slowly being accepted for use by international regulatory authorities. Because regulatory acceptance itself has not guaranteed that approved humane methods are adopted by manufacturers, various organizations have sought to foster the preferential use of validated non-animal methods by interfacing with industry and regulatory authorities. After noticing this gap between regulation and uptake by industry, we began developing a paradigm that seeks to narrow the gap and quicken implementation of new replacement, refinement or reduction guidance. A systematic analysis of our experience in promoting the transparent implementation of validated non-animal vaccine potency assays has led to the refinement of our paradigmatic process, presented here, by which interested parties can assess the local regulatory acceptance of methods that reduce animal use and integrate them into quality control testing protocols, or ensure the elimination of peripheral barriers to their use, particularly for potency and other tests carried out on production batches.

  4. Bridging the Gap Between Validation and Implementation of Non-Animal Veterinary Vaccine Potency Testing Methods.

    Science.gov (United States)

    Dozier, Samantha; Brown, Jeffrey; Currie, Alistair

    2011-11-29

    In recent years, technologically advanced high-throughput techniques have been developed that replace, reduce or refine animal use in vaccine quality control tests. Following validation, these tests are slowly being accepted for use by international regulatory authorities. Because regulatory acceptance itself has not guaranteed that approved humane methods are adopted by manufacturers, various organizations have sought to foster the preferential use of validated non-animal methods by interfacing with industry and regulatory authorities. After noticing this gap between regulation and uptake by industry, we began developing a paradigm that seeks to narrow the gap and quicken implementation of new replacement, refinement or reduction guidance. A systematic analysis of our experience in promoting the transparent implementation of validated non-animal vaccine potency assays has led to the refinement of our paradigmatic process, presented here, by which interested parties can assess the local regulatory acceptance of methods that reduce animal use and integrate them into quality control testing protocols, or ensure the elimination of peripheral barriers to their use, particularly for potency and other tests carried out on production batches.

  5. A Multiscale Finite Element Model Validation Method of Composite Cable-Stayed Bridge Based on Structural Health Monitoring System

    Directory of Open Access Journals (Sweden)

    Rumian Zhong

    2015-01-01

    Full Text Available A two-step response surface method for multiscale finite element model (FEM updating and validation is presented with respect to Guanhe Bridge, a composite cable-stayed bridge in the National Highway number G15, in China. Firstly, the state equations of both multiscale and single-scale FEM are established based on the basic equation in structural dynamic mechanics to update the multiscale coupling parameters and structural parameters. Secondly, based on the measured data from the structural health monitoring (SHM system, a Monte Carlo simulation is employed to analyze the uncertainty quantification and transmission, where the uncertainties of the multiscale FEM and measured data were considered. The results indicate that the relative errors between the calculated and measured frequencies are less than 2%, and the overlap ratio indexes of each modal frequency are larger than 80% without the average absolute value of relative errors. These demonstrate that the proposed method can be applied to validate the multiscale FEM, and the validated FEM can reflect the current conditions of the real bridge; thus it can be used as the basis for bridge health monitoring, damage prognosis (DP, and safety prognosis (SP.

  6. Methods and practices for verification and validation of programmable systems

    International Nuclear Information System (INIS)

    Heimbuerger, H.; Haapanen, P.; Pulkkinen, U.

    1993-01-01

    The programmable systems deviate by their properties and behaviour from the conventional non-programmable systems in such extent, that their verification and validation for safety critical applications requires new methods and practices. The safety assessment can not be based on conventional probabilistic methods due to the difficulties in the quantification of the reliability of the software and hardware. The reliability estimate of the system must be based on qualitative arguments linked to a conservative claim limit. Due to the uncertainty of the quantitative reliability estimate other means must be used to get more assurance about the system safety. Methods and practices based on research done by VTT for STUK, are discussed in the paper as well as the methods applicable in the reliability analysis of software based safety functions. The most essential concepts and models of quantitative reliability analysis are described. The application of software models in probabilistic safety analysis (PSA) is evaluated. (author). 18 refs

  7. Parallel Resolved Open Source CFD-DEM: Method, Validation and Application

    Directory of Open Access Journals (Sweden)

    A. Hager

    2014-03-01

    Full Text Available In the following paper the authors present a fully parallelized Open Source method for calculating the interaction of immersed bodies and surrounding fluid. A combination of computational fluid dynamics (CFD and a discrete element method (DEM accounts for the physics of both the fluid and the particles. The objects considered are relatively big compared to the cells of the fluid mesh, i.e. they cover several cells each. Thus this fictitious domain method (FDM is called resolved. The implementation is realized within the Open Source framework CFDEMcOupling (www.cfdem.com, which provides an interface between OpenFOAM® based CFD-solvers and the DEM software LIGGGHTS (www.liggghts.com. While both LIGGGHTS and OpenFOAM® were already parallelized, only a recent improvement of the algorithm permits the fully parallel computation of resolved problems. Alongside with a detailed description of the method, its implementation and recent improvements, a number of application and validation examples is presented in the scope of this paper.

  8. Methods and procedures for the verification and validation of artificial neural networks

    CERN Document Server

    Taylor, Brian J

    2006-01-01

    Neural networks are members of a class of software that have the potential to enable intelligent computational systems capable of simulating characteristics of biological thinking and learning. This volume introduces some of the methods and techniques used for the verification and validation of neural networks and adaptive systems.

  9. Validity Argument for Assessing L2 Pragmatics in Interaction Using Mixed Methods

    Science.gov (United States)

    Youn, Soo Jung

    2015-01-01

    This study investigates the validity of assessing L2 pragmatics in interaction using mixed methods, focusing on the evaluation inference. Open role-plays that are meaningful and relevant to the stakeholders in an English for Academic Purposes context were developed for classroom assessment. For meaningful score interpretations and accurate…

  10. Development and validation of a simplified titration method for monitoring volatile fatty acids in anaerobic digestion.

    Science.gov (United States)

    Sun, Hao; Guo, Jianbin; Wu, Shubiao; Liu, Fang; Dong, Renjie

    2017-09-01

    The volatile fatty acids (VFAs) concentration has been considered as one of the most sensitive process performance indicators in anaerobic digestion (AD) process. However, the accurate determination of VFAs concentration in AD processes normally requires advanced equipment and complex pretreatment procedures. A simplified method with fewer sample pretreatment procedures and improved accuracy is greatly needed, particularly for on-site application. This report outlines improvements to the Nordmann method, one of the most popular titrations used for VFA monitoring. The influence of ion and solid interfering subsystems in titrated samples on results accuracy was discussed. The total solid content in titrated samples was the main factor affecting accuracy in VFA monitoring. Moreover, a high linear correlation was established between the total solids contents and VFA measurement differences between the traditional Nordmann equation and gas chromatography (GC). Accordingly, a simplified titration method was developed and validated using a semi-continuous experiment of chicken manure anaerobic digestion with various organic loading rates. The good fitting of the results obtained by this method in comparison with GC results strongly supported the potential application of this method to VFA monitoring. Copyright © 2017. Published by Elsevier Ltd.

  11. Validity of the remote food photography method against doubly labeled water among minority preschoolers

    Science.gov (United States)

    The aim of this study was to determine the validity of energy intake (EI) estimations made using the remote food photography method (RFPM) compared to the doubly labeled water (DLW) method in minority preschool children in a free-living environment. Seven days of food intake and spot urine samples...

  12. Determination of perfluorinated compounds in fish fillet homogenates: method validation and application to fillet homogenates from the Mississippi River.

    Science.gov (United States)

    Malinsky, Michelle Duval; Jacoby, Cliffton B; Reagen, William K

    2011-01-10

    We report herein a simple protein precipitation extraction-liquid chromatography tandem mass spectrometry (LC/MS/MS) method, validation, and application for the analysis of perfluorinated carboxylic acids (C7-C12), perfluorinated sulfonic acids (C4, C6, and C8), and perfluorooctane sulfonamide (FOSA) in fish fillet tissue. The method combines a rapid homogenization and protein precipitation tissue extraction procedure using stable-isotope internal standard (IS) calibration. Method validation in bluegill (Lepomis macrochirus) fillet tissue evaluated the following: (1) method accuracy and precision in both extracted matrix-matched calibration and solvent (unextracted) calibration, (2) quantitation of mixed branched and linear isomers of perfluorooctanoate (PFOA) and perfluorooctanesulfonate (PFOS) with linear isomer calibration, (3) quantitation of low level (ppb) perfluorinated compounds (PFCs) in the presence of high level (ppm) PFOS, and (4) specificity from matrix interferences. Both calibration techniques produced method accuracy of at least 100±13% with a precision (%RSD) ≤18% for all target analytes. Method accuracy and precision results for fillet samples from nine different fish species taken from the Mississippi River in 2008 and 2009 are also presented. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. 42 CFR 476.85 - Conclusive effect of QIO initial denial determinations and changes as a result of DRG validations.

    Science.gov (United States)

    2010-10-01

    ... determinations and changes as a result of DRG validations. 476.85 Section 476.85 Public Health CENTERS FOR... denial determinations and changes as a result of DRG validations. A QIO initial denial determination or change as a result of DRG validation is final and binding unless, in accordance with the procedures in...

  14. The construct validity of the Spanish version of the ABQ using a multi-trait/multi-method approach

    Directory of Open Access Journals (Sweden)

    Thomas D. Raedeke

    2013-10-01

    Full Text Available This study was designed to evaluate construct validity evidence associated with the Spanish version of the Athlete Burnout Questionnaire (ABQ using a multi-trait/multi-method (MTMM approach. The ABQ was administered to a sample of 302 Spanish athletes, along with two other questionnaires including the Maslach Burnout Inventory-General Survey (MBI-GS and the Depression, Anxiety, Stress Scale (DASS-21, which respectively measure burnout in organizational settings and indicators of ill being including depression, anxiety and stress. A structural equation modeling approach to a MTMM analysis was used. Results revealed by comparative analysis of four models that the Spanish version of ABQ has convergent and internal discriminant validity evident by high correlations between matching burnout subscales across two measures and lower correlations between non-matching dimensions. In addition, the burnout measures exhibited external discriminant validity as the correlations between burnout dimensions were higher than those seen between conceptually related, but unique, constructs.

  15. Detailed validation in PCDDF analysis. ISO17025 data from Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Kernick Carvalhaes, G.; Azevedo, J.A.; Azevedo, G.; Machado, M.; Brooks, P. [Analytical Solutions, Rio de Janeiro (Brazil)

    2004-09-15

    When we define validation method we can use the ISO standard 8402, in reference to this, 'validation' is the 'confirmation by the examination and supplying of objective evidences that the particular requirements for a specific intended use are fulfilled'. This concept is extremely important to guarantee the quality of results. Validation method is based on the combined use of different validation procedures, but in this selection we have to analyze the cost benefit conditions. We must focus on the critical elements, and these critical factors must be the essential elements for providing good properties and results. If we have a solid validation methodology and a research of the source of uncertainty of our analytical method, we can generate results with confidence and veracity. When analyzing these two considerations, validation method and uncertainty calculations, we found out that there are very few articles and papers about these subjects, and it is even more difficult to find such materials on dioxins and furans. This short paper describes a validation and uncertainty calculation methodology using traditional studies with a few adaptations, yet it shows a new idea of recovery study as a source of uncertainty.

  16. Validation of the Abdominal Pain Index using a revised scoring method.

    Science.gov (United States)

    Laird, Kelsey T; Sherman, Amanda L; Smith, Craig A; Walker, Lynn S

    2015-06-01

    Evaluate the psychometric properties of child- and parent-report versions of the four-item Abdominal Pain Index (API) in children with functional abdominal pain (FAP) and healthy controls, using a revised scoring method that facilitates comparisons of scores across samples and time. Pediatric patients aged 8-18 years with FAP and controls completed the API at baseline (N = 1,967); a subset of their parents (N = 290) completed the API regarding the child's pain. Subsets of patients completed follow-up assessments at 2 weeks (N = 231), 3 months (N = 330), and 6 months (N = 107). Subsets of both patients (N = 389) and healthy controls (N = 172) completed a long-term follow-up assessment (mean age at follow-up = 20.21 years, SD = 3.75). The API demonstrated good concurrent, discriminant, and construct validity, as well as good internal consistency. We conclude that the API, using the revised scoring method, is a useful, reliable, and valid measure of abdominal pain severity. © The Author 2015. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Validation approach for a fast and simple targeted screening method for 75 antibiotics in meat and aquaculture products using LC-MS/MS.

    Science.gov (United States)

    Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique

    2017-04-01

    An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.

  18. A method of validating climate models in climate research with a view to extreme events; Eine Methode zur Validierung von Klimamodellen fuer die Klimawirkungsforschung hinsichtlich der Wiedergabe extremer Ereignisse

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, U

    2000-08-01

    A method is presented to validate climate models with respect to extreme events which are suitable for risk assessment in impact modeling. The algorithm is intended to complement conventional techniques. These procedures mainly compare simulation results with reference data based on single or only a few climatic variables at the same time under the aspect how well a model performs in reproducing the known physical processes of the atmosphere. Such investigations are often based on seasonal or annual mean values. For impact research, however, extreme climatic conditions with shorter typical time scales are generally more interesting. Furthermore, such extreme events are frequently characterized by combinations of individual extremes which require a multivariate approach. The validation method presented here basically consists of a combination of several well-known statistical techniques, completed by a newly developed diagnosis module to quantify model deficiencies. First of all, critical threshold values of key climatic variables for impact research have to be derived serving as criteria to define extreme conditions for a specific activity. Unlike in other techniques, the simulation results to be validated are interpolated to the reference data sampling points in the initial step of this new technique. Besides that fact that the same spatial representation is provided in this way in both data sets for the next diagnostic steps, this procedure also enables to leave the reference basis unchanged for any type of model output and to perform the validation on a real orography. To simultaneously identify the spatial characteristics of a given situation regarding all considered extreme value criteria, a multivariate cluster analysis method for pattern recognition is separately applied to both simulation results and reference data. Afterwards, various distribution-free statistical tests are applied depending on the specific situation to detect statistical significant

  19. A method of validating climate models in climate research with a view to extreme events; Eine Methode zur Validierung von Klimamodellen fuer die Klimawirkungsforschung hinsichtlich der Wiedergabe extremer Ereignisse

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, U.

    2000-08-01

    A method is presented to validate climate models with respect to extreme events which are suitable for risk assessment in impact modeling. The algorithm is intended to complement conventional techniques. These procedures mainly compare simulation results with reference data based on single or only a few climatic variables at the same time under the aspect how well a model performs in reproducing the known physical processes of the atmosphere. Such investigations are often based on seasonal or annual mean values. For impact research, however, extreme climatic conditions with shorter typical time scales are generally more interesting. Furthermore, such extreme events are frequently characterized by combinations of individual extremes which require a multivariate approach. The validation method presented here basically consists of a combination of several well-known statistical techniques, completed by a newly developed diagnosis module to quantify model deficiencies. First of all, critical threshold values of key climatic variables for impact research have to be derived serving as criteria to define extreme conditions for a specific activity. Unlike in other techniques, the simulation results to be validated are interpolated to the reference data sampling points in the initial step of this new technique. Besides that fact that the same spatial representation is provided in this way in both data sets for the next diagnostic steps, this procedure also enables to leave the reference basis unchanged for any type of model output and to perform the validation on a real orography. To simultaneously identify the spatial characteristics of a given situation regarding all considered extreme value criteria, a multivariate cluster analysis method for pattern recognition is separately applied to both simulation results and reference data. Afterwards, various distribution-free statistical tests are applied depending on the specific situation to detect statistical significant

  20. Content validity across methods of malnutrition assessment in patients with cancer is limited

    NARCIS (Netherlands)

    Sealy, Martine J.; Nijholt, Willemke; Stuiver, Martijn M.; van der Berg, Marit M.; Roodenburg, Jan L. N.; Schans, van der Cees P.; Ottery, Faith D.; Jager-Wittenaar, Harriet

    Objective: To identify malnutrition assessment methods in cancer patients and assess their content validity based on internationally accepted definitions for malnutrition. Study Design and Setting: Systematic review of studies in cancer patients that operationalized malnutrition as a variable,

  1. Content validity across methods of malnutrition assessment in patients with cancer is limited

    NARCIS (Netherlands)

    Sealy, Martine; Nijholt, Willemke; Stuiver, M.M.; van der Berg, M.M.; Roodenburg, Jan; Ottery, Faith D.; van der Schans, Cees; Jager, Harriët

    2016-01-01

    Objective To identify malnutrition assessment methods in cancer patients and assess their content validity based on internationally accepted definitions for malnutrition. Study Design and Setting Systematic review of studies in cancer patients that operationalized malnutrition as a variable,

  2. Analytical Validation of a New Enzymatic and Automatable Method for d-Xylose Measurement in Human Urine Samples

    Directory of Open Access Journals (Sweden)

    Israel Sánchez-Moreno

    2017-01-01

    Full Text Available Hypolactasia, or intestinal lactase deficiency, affects more than half of the world population. Currently, xylose quantification in urine after gaxilose oral administration for the noninvasive diagnosis of hypolactasia is performed with the hand-operated nonautomatable phloroglucinol reaction. This work demonstrates that a new enzymatic xylose quantification method, based on the activity of xylose dehydrogenase from Caulobacter crescentus, represents an excellent alternative to the manual phloroglucinol reaction. The new method is automatable and facilitates the use of the gaxilose test for hypolactasia diagnosis in the clinical practice. The analytical validation of the new technique was performed in three different autoanalyzers, using buffer or urine samples spiked with different xylose concentrations. For the comparison between the phloroglucinol and the enzymatic assays, 224 urine samples of patients to whom the gaxilose test had been prescribed were assayed by both methods. A mean bias of −16.08 mg of xylose was observed when comparing the results obtained by both techniques. After adjusting the cut-off of the enzymatic method to 19.18 mg of xylose, the Kappa coefficient was found to be 0.9531, indicating an excellent level of agreement between both analytical procedures. This new assay represents the first automatable enzymatic technique validated for xylose quantification in urine.

  3. Numerical and experimental validation of a particle Galerkin method for metal grinding simulation

    Science.gov (United States)

    Wu, C. T.; Bui, Tinh Quoc; Wu, Youcai; Luo, Tzui-Liang; Wang, Morris; Liao, Chien-Chih; Chen, Pei-Yin; Lai, Yu-Sheng

    2018-03-01

    In this paper, a numerical approach with an experimental validation is introduced for modelling high-speed metal grinding processes in 6061-T6 aluminum alloys. The derivation of the present numerical method starts with an establishment of a stabilized particle Galerkin approximation. A non-residual penalty term from strain smoothing is introduced as a means of stabilizing the particle Galerkin method. Additionally, second-order strain gradients are introduced to the penalized functional for the regularization of damage-induced strain localization problem. To handle the severe deformation in metal grinding simulation, an adaptive anisotropic Lagrangian kernel is employed. Finally, the formulation incorporates a bond-based failure criterion to bypass the prospective spurious damage growth issues in material failure and cutting debris simulation. A three-dimensional metal grinding problem is analyzed and compared with the experimental results to demonstrate the effectiveness and accuracy of the proposed numerical approach.

  4. Development, validation and evaluation of an analytical method for the determination of monomeric and oligomeric procyanidins in apple extracts.

    Science.gov (United States)

    Hollands, Wendy J; Voorspoels, Stefan; Jacobs, Griet; Aaby, Kjersti; Meisland, Ane; Garcia-Villalba, Rocio; Tomas-Barberan, Francisco; Piskula, Mariusz K; Mawson, Deborah; Vovk, Irena; Needs, Paul W; Kroon, Paul A

    2017-04-28

    There is a lack of data for individual oligomeric procyanidins in apples and apple extracts. Our aim was to develop, validate and evaluate an analytical method for the separation, identification and quantification of monomeric and oligomeric flavanols in apple extracts. To achieve this, we prepared two types of flavanol extracts from freeze-dried apples; one was an epicatechin-rich extract containing ∼30% (w/w) monomeric (-)-epicatechin which also contained oligomeric procyanidins (Extract A), the second was an oligomeric procyanidin-rich extract depleted of epicatechin (Extract B). The parameters considered for method optimisation were HPLC columns and conditions, sample heating, mass of extract and dilution volumes. The performance characteristics considered for method validation included standard linearity, method sensitivity, precision and trueness. Eight laboratories participated in the method evaluation. Chromatographic separation of the analytes was best achieved utilizing a Hilic column with a binary mobile phase consisting of acidic acetonitrile and acidic aqueous methanol. The final method showed linearity for epicatechin in the range 5-100μg/mL with a correlation co-efficient >0.999. Intra-day and inter-day precision of the analytes ranged from 2 to 6% and 2 to 13% respectively. Up to dp3, trueness of the method was >95% but decreased with increasing dp. Within laboratory precision showed RSD values <5 and 10% for monomers and oligomers, respectively. Between laboratory precision was 4 and 15% (Extract A) and 7 and 30% (Extract B) for monomers and oligomers, respectively. An analytical method for the separation, identification and quantification of procyanidins in an apple extract was developed, validated and assessed. The results of the inter-laboratory evaluation indicate that the method is reliable and reproducible. Copyright © 2017. Published by Elsevier B.V.

  5. A Systematic Review of Validated Methods for Identifying Cerebrovascular Accident or Transient Ischemic Attack Using Administrative Data

    Science.gov (United States)

    Andrade, Susan E.; Harrold, Leslie R.; Tjia, Jennifer; Cutrona, Sarah L.; Saczynski, Jane S.; Dodd, Katherine S.; Goldberg, Robert J.; Gurwitz, Jerry H.

    2012-01-01

    Purpose To perform a systematic review of the validity of algorithms for identifying cerebrovascular accidents (CVAs) or transient ischemic attacks (TIAs) using administrative and claims data. Methods PubMed and Iowa Drug Information Service (IDIS) searches of the English language literature were performed to identify studies published between 1990 and 2010 that evaluated the validity of algorithms for identifying CVAs (ischemic and hemorrhagic strokes, intracranial hemorrhage and subarachnoid hemorrhage) and/or TIAs in administrative data. Two study investigators independently reviewed the abstracts and articles to determine relevant studies according to pre-specified criteria. Results A total of 35 articles met the criteria for evaluation. Of these, 26 articles provided data to evaluate the validity of stroke, 7 reported the validity of TIA, 5 reported the validity of intracranial bleeds (intracerebral hemorrhage and subarachnoid hemorrhage), and 10 studies reported the validity of algorithms to identify the composite endpoints of stroke/TIA or cerebrovascular disease. Positive predictive values (PPVs) varied depending on the specific outcomes and algorithms evaluated. Specific algorithms to evaluate the presence of stroke and intracranial bleeds were found to have high PPVs (80% or greater). Algorithms to evaluate TIAs in adult populations were generally found to have PPVs of 70% or greater. Conclusions The algorithms and definitions to identify CVAs and TIAs using administrative and claims data differ greatly in the published literature. The choice of the algorithm employed should be determined by the stroke subtype of interest. PMID:22262598

  6. Introducing conjoint analysis method into delayed lotteries studies: its validity and time stability are higher than in adjusting.

    Science.gov (United States)

    Białek, Michał; Markiewicz, Łukasz; Sawicki, Przemysław

    2015-01-01

    The delayed lotteries are much more common in everyday life than are pure lotteries. Usually, we need to wait to find out the outcome of the risky decision (e.g., investing in a stock market, engaging in a relationship). However, most research has studied the time discounting and probability discounting in isolation using the methodologies designed specifically to track changes in one parameter. Most commonly used method is adjusting, but its reported validity and time stability in research on discounting are suboptimal. The goal of this study was to introduce the novel method for analyzing delayed lotteries-conjoint analysis-which hypothetically is more suitable for analyzing individual preferences in this area. A set of two studies compared the conjoint analysis with adjusting. The results suggest that individual parameters of discounting strength estimated with conjoint have higher predictive value (Study 1 and 2), and they are more stable over time (Study 2) compared to adjusting. We discuss these findings, despite the exploratory character of reported studies, by suggesting that future research on delayed lotteries should be cross-validated using both methods.

  7. Introducing conjoint analysis method into delayed lotteries studies: Its validity and time stability are higher than in adjusting

    Directory of Open Access Journals (Sweden)

    Michal eBialek

    2015-01-01

    Full Text Available The delayed lotteries are much more common in everyday life than are pure lotteries. Usually, we need to wait to find out the outcome of the risky decision (e.g., investing in a stock market, engaging in a relationship. However, most research has studied the time discounting and probability discounting in isolation using the methodologies designed specifically to track changes in one parameter. Most commonly used method is adjusting, but its reported validity and time stability in research on discounting are suboptimal.The goal of this study was to introduce the novel method for analyzing delayed lotteries - conjoint analysis - which hypothetically is more suitable for analyzing individual preferences in this area. A set of two studies compared the conjoint analysis with adjusting. The results suggest that individual parameters of discounting strength estimated with conjoint have higher predictive value (Study 1 & 2, and they are more stable over time (Study 2 compared to adjusting. We discuss these findings, despite the exploratory character of reported studies, by suggesting that future research on delayed lotteries should be cross-validated using both methods.

  8. A new method to model electroconvulsive therapy in rats with increased construct validity and enhanced translational value.

    Science.gov (United States)

    Theilmann, Wiebke; Löscher, Wolfgang; Socala, Katarzyna; Frieling, Helge; Bleich, Stefan; Brandt, Claudia

    2014-06-01

    Electroconvulsive therapy is the most effective therapy for major depressive disorder (MDD). The remission rate is above 50% in previously pharmacoresistant patients but the mechanisms of action are not fully understood. Electroconvulsive stimulation (ECS) in rodents mimics antidepressant electroconvulsive therapy (ECT) in humans and is widely used to investigate the underlying mechanisms of ECT. For the translational value of findings in animal models it is essential to establish models with the highest construct, face and predictive validity possible. The commonly used model for ECT in rodents does not meet the demand for high construct validity. For ECT, cortical surface electrodes are used to induce therapeutic seizures whereas ECS in rodents is exclusively performed by auricular or corneal electrodes. However, the stimulation site has a major impact on the type and spread of the induced seizure activity and its antidepressant effect. We propose a method in which ECS is performed by screw electrodes placed above the motor cortex of rats to closely simulate the clinical situation and thereby increase the construct validity of the model. Cortical ECS in rats induced reliably seizures comparable to human ECT. Cortical ECS was more effective than auricular ECS to reduce immobility in the forced swim test. Importantly, auricular stimulation had a negative influence on the general health condition of the rats with signs of fear during the stimulation sessions. These results suggest that auricular ECS in rats is not a suitable ECT model. Cortical ECS in rats promises to be a valid method to mimic ECT. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Validation of an HPLC method for determination of chemical purity of [18F]fluoromisonidazole ([18F]FMISO)

    International Nuclear Information System (INIS)

    Nascimento, Natalia C.E.S.; Oliveira, Mércia L.; Lima, Fernando R.A.; Silveira, Marina B.; Ferreira, Soraya Z.; Silva, Juliana B.

    2017-01-01

    [ 18 F]Fluoromisonidazole ([ 18 F]FMISO) is a nitroimidazole derivative labelled with fluorine-18 that selectively binds to hypoxic cells. It has been shown to be a suitable PET tracer for imaging hypoxia in tumors as well as in noncancerous tissues. [ 18 F]FMISO was prepared using a TRACERlabMX FDG ® module (GE) with cassettes, software sequence and reagents kits from ABX. In this work, we aimed to develop and to validate a new high performance liquid chromatography (HPLC) method for determination of chemical purity of [ 18 F]FMISO. Analyses were performed with an Agilent chromatograph equipped with radioactivity and UV detectors. [ 18 F]FMISO and impurities were separated on a C18 column by gradient elution with water and acetonitrile. Selectivity, linearity, detection limit (DL), quantification limit (LQ), precision, accuracy and robustness were assessed to demonstrate that the HPLC method is adequate for its intended purpose. The HPLC method showed a good precision, as all RSD values were lower than 5%. Robustness was evaluated considering a variation on parameters such mobile phase gradient and flow rate. Results evidenced that the HPLC method is validated and is suitable for radiochemical purity evaluation of [ 18 F]FMISO, considering operational conditions of our laboratory. As an extension of this work, other analytical methods used for [ 18 F]FMISO quality control should be evaluated, in compliance with good manufacture practice. (author)

  10. Estimating misclassification error: a closer look at cross-validation based methods

    Directory of Open Access Journals (Sweden)

    Ounpraseuth Songthip

    2012-11-01

    Full Text Available Abstract Background To estimate a classifier’s error in predicting future observations, bootstrap methods have been proposed as reduced-variation alternatives to traditional cross-validation (CV methods based on sampling without replacement. Monte Carlo (MC simulation studies aimed at estimating the true misclassification error conditional on the training set are commonly used to compare CV methods. We conducted an MC simulation study to compare a new method of bootstrap CV (BCV to k-fold CV for estimating clasification error. Findings For the low-dimensional conditions simulated, the modest positive bias of k-fold CV contrasted sharply with the substantial negative bias of the new BCV method. This behavior was corroborated using a real-world dataset of prognostic gene-expression profiles in breast cancer patients. Our simulation results demonstrate some extreme characteristics of variance and bias that can occur due to a fault in the design of CV exercises aimed at estimating the true conditional error of a classifier, and that appear not to have been fully appreciated in previous studies. Although CV is a sound practice for estimating a classifier’s generalization error, using CV to estimate the fixed misclassification error of a trained classifier conditional on the training set is problematic. While MC simulation of this estimation exercise can correctly represent the average bias of a classifier, it will overstate the between-run variance of the bias. Conclusions We recommend k-fold CV over the new BCV method for estimating a classifier’s generalization error. The extreme negative bias of BCV is too high a price to pay for its reduced variance.

  11. Numerical Validation of the Delaunay Normalization and the Krylov-Bogoliubov-Mitropolsky Method

    Directory of Open Access Journals (Sweden)

    David Ortigosa

    2014-01-01

    Full Text Available A scalable second-order analytical orbit propagator programme based on modern and classical perturbation methods is being developed. As a first step in the validation and verification of part of our orbit propagator programme, we only consider the perturbation produced by zonal harmonic coefficients in the Earth’s gravity potential, so that it is possible to analyze the behaviour of the mathematical expressions involved in Delaunay normalization and the Krylov-Bogoliubov-Mitropolsky method in depth and determine their limits.

  12. Validation of the quality control method for sodium dicloxacillin in Dicloxen capsules

    International Nuclear Information System (INIS)

    Rodriguez Hernandez, Yaslenis; Perez Navarro, Maikel; Suarez Perez, Yania

    2014-01-01

    Sodium dicloxacillin is a semi synthetic derivative of the isoxasocyl penicillin group that may appear in oral suspension form and in caplets. For the analysis of the raw materials and the finished products, it is recommended to use high performance liquid chromatography that is an unavailable method at the dicloxen capsule manufacturing lab for the routine analysis of the drug. To develop and to validate a useful ultraviolet spectrophotometry method for the quality control of sodium dicloxacillin in Dicloxen capsules

  13. A validation framework for microbial forensic methods based on statistical pattern recognition

    Energy Technology Data Exchange (ETDEWEB)

    Velsko, S P

    2007-11-12

    This report discusses a general approach to validating microbial forensic methods that attempt to simultaneously distinguish among many hypotheses concerning the manufacture of a questioned biological agent sample. It focuses on the concrete example of determining growth medium from chemical or molecular properties of a bacterial agent to illustrate the concepts involved.

  14. Determination of proline in honey: comparison between official methods, optimization and validation of the analytical methodology.

    Science.gov (United States)

    Truzzi, Cristina; Annibaldi, Anna; Illuminati, Silvia; Finale, Carolina; Scarponi, Giuseppe

    2014-05-01

    The study compares official spectrophotometric methods for the determination of proline content in honey - those of the International Honey Commission (IHC) and the Association of Official Analytical Chemists (AOAC) - with the original Ough method. Results show that the extra time-consuming treatment stages added by the IHC method with respect to the Ough method are pointless. We demonstrate that the AOACs method proves to be the best in terms of accuracy and time saving. The optimized waiting time for the absorbance recording is set at 35min from the removal of reaction tubes from the boiling bath used in the sample treatment. The optimized method was validated in the matrix: linearity up to 1800mgL(-1), limit of detection 20mgL(-1), limit of quantification 61mgL(-1). The method was applied to 43 unifloral honey samples from the Marche region, Italy. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Convergent validity test, construct validity test and external validity test of the David Liberman algorithm

    Directory of Open Access Journals (Sweden)

    David Maldavsky

    2013-08-01

    Full Text Available The author first exposes a complement of a previous test about convergent validity, then a construct validity test and finally an external validity test of the David Liberman algorithm.  The first part of the paper focused on a complementary aspect, the differential sensitivity of the DLA 1 in an external comparison (to other methods, and 2 in an internal comparison (between two ways of using the same method, the DLA.  The construct validity test exposes the concepts underlined to DLA, their operationalization and some corrections emerging from several empirical studies we carried out.  The external validity test examines the possibility of using the investigation of a single case and its relation with the investigation of a more extended sample.

  16. Statistical approach for selection of regression model during validation of bioanalytical method

    Directory of Open Access Journals (Sweden)

    Natalija Nakov

    2014-06-01

    Full Text Available The selection of an adequate regression model is the basis for obtaining accurate and reproducible results during the bionalytical method validation. Given the wide concentration range, frequently present in bioanalytical assays, heteroscedasticity of the data may be expected. Several weighted linear and quadratic regression models were evaluated during the selection of the adequate curve fit using nonparametric statistical tests: One sample rank test and Wilcoxon signed rank test for two independent groups of samples. The results obtained with One sample rank test could not give statistical justification for the selection of linear vs. quadratic regression models because slight differences between the error (presented through the relative residuals were obtained. Estimation of the significance of the differences in the RR was achieved using Wilcoxon signed rank test, where linear and quadratic regression models were treated as two independent groups. The application of this simple non-parametric statistical test provides statistical confirmation of the choice of an adequate regression model.

  17. Construct Validity and Scoring Methods of the World Health Organization: Health and Work Performance Questionnaire Among Workers With Arthritis and Rheumatological Conditions.

    Science.gov (United States)

    AlHeresh, Rawan; LaValley, Michael P; Coster, Wendy; Keysor, Julie J

    2017-06-01

    To evaluate construct validity and scoring methods of the world health organization-health and work performance questionnaire (HPQ) for people with arthritis. Construct validity was examined through hypothesis testing using the recommended guidelines of the consensus-based standards for the selection of health measurement instruments (COSMIN). The HPQ using the absolute scoring method showed moderate construct validity as four of the seven hypotheses were met. The HPQ using the relative scoring method had weak construct validity as only one of the seven hypotheses were met. The absolute scoring method for the HPQ is superior in construct validity to the relative scoring method in assessing work performance among people with arthritis and related rheumatic conditions; however, more research is needed to further explore other psychometric properties of the HPQ.

  18. Development and validation of a reversed phase liquid chromatographic method for analysis of oxytetracycline and related impurities.

    Science.gov (United States)

    Kahsay, Getu; Shraim, Fairouz; Villatte, Philippe; Rotger, Jacques; Cassus-Coussère, Céline; Van Schepdael, Ann; Hoogmartens, Jos; Adams, Erwin

    2013-03-05

    A simple, robust and fast high-performance liquid chromatographic method is described for the analysis of oxytetracycline and its related impurities. The principal peak and impurities are all baseline separated in 20 min using an Inertsil C₈ (150 mm × 4.6 mm, 5 μm) column kept at 50 °C. The mobile phase consists of a gradient mixture of mobile phases A (0.05% trifluoroacetic acid in water) and B (acetonitrile-methanol-tetrahydrofuran, 80:15:5, v/v/v) pumped at a flow rate of 1.3 ml/min. UV detection was performed at 254 nm. The developed method was validated for its robustness, sensitivity, precision and linearity in the range from limit of quantification (LOQ) to 120%. The limits of detection (LOD) and LOQ were found to be 0.08 μg/ml and 0.32 μg/ml, respectively. This method allows the separation of oxytetracycline from all known and 5 unknown impurities, which is better than previously reported in the literature. Moreover, the simple mobile phase composition devoid of non-volatile buffers made the method suitable to interface with mass spectrometry for further characterization of unknown impurities. The developed method has been applied for determination of related substances in oxytetracycline bulk samples available from four manufacturers. The validation results demonstrate that the method is reliable for quantification of oxytetracycline and its impurities. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. A Validated Method for the Quality Control of Andrographis paniculata Preparations.

    Science.gov (United States)

    Karioti, Anastasia; Timoteo, Patricia; Bergonzi, Maria Camilla; Bilia, Anna Rita

    2017-10-01

    Andrographis paniculata is a herbal drug of Asian traditional medicine largely employed for the treatment of several diseases. Recently, it has been introduced in Europe for the prophylactic and symptomatic treatment of common cold and as an ingredient of dietary supplements. The active principles are diterpenes with andrographolide as the main representative. In the present study, an analytical protocol was developed for the determination of the main constituents in the herb and preparations of A. paniculata . Three different extraction protocols (methanol extraction using a modified Soxhlet procedure, maceration under ultrasonication, and decoction) were tested. Ultrasonication achieved the highest content of analytes. HPLC conditions were optimized in terms of solvent mixtures, time course, and temperature. A reversed phase C18 column eluted with a gradient system consisting of acetonitrile and acidified water and including an isocratic step at 30 °C was used. The HPLC method was validated for linearity, limits of quantitation and detection, repeatability, precision, and accuracy. The overall method was validated for precision and accuracy over at least three different concentration levels. Relative standard deviation was less than 1.13%, whereas recovery was between 95.50% and 97.19%. The method also proved to be suitable for the determination of a large number of commercial samples and was proposed to the European Pharmacopoeia for the quality control of Andrographidis herba. Georg Thieme Verlag KG Stuttgart · New York.

  20. Results from the radiometric validation of Sentinel-3 optical sensors using natural targets

    Science.gov (United States)

    Fougnie, Bertrand; Desjardins, Camille; Besson, Bruno; Bruniquel, Véronique; Meskini, Naceur; Nieke, Jens; Bouvet, Marc

    2016-09-01

    The recently launched SENTINEL-3 mission measures sea surface topography, sea/land surface temperature, and ocean/land surface colour with high accuracy. The mission provides data continuity with the ENVISAT mission through acquisitions by multiple sensing instruments. Two of them, OLCI (Ocean and Land Colour Imager) and SLSTR (Sea and Land Surface Temperature Radiometer) are optical sensors designed to provide continuity with Envisat's MERIS and AATSR instruments. During the commissioning, in-orbit calibration and validation activities are conducted. Instruments are in-flight calibrated and characterized primarily using on-board devices which include diffusers and black body. Afterward, vicarious calibration methods are used in order to validate the OLCI and SLSTR radiometry for the reflective bands. The calibration can be checked over dedicated natural targets such as Rayleigh scattering, sunglint, desert sites, Antarctica, and tentatively deep convective clouds. Tools have been developed and/or adapted (S3ETRAC, MUSCLE) to extract and process Sentinel-3 data. Based on these matchups, it is possible to provide an accurate checking of many radiometric aspects such as the absolute and interband calibrations, the trending correction, the calibration consistency within the field-of-view, and more generally this will provide an evaluation of the radiometric consistency for various type of targets. Another important aspect will be the checking of cross-calibration between many other instruments such as MERIS and AATSR (bridge between ENVISAT and Sentinel-3), MODIS (bridge to the GSICS radiometric standard), as well as Sentinel-2 (bridge between Sentinel missions). The early results, based on the available OLCI and SLSTR data, will be presented and discussed.

  1. Lodenafil carbonate tablets: optimization and validation of a capillary zone electrophoresis method

    OpenAIRE

    Codevilla, Cristiane F; Ferreira, Pâmela Cristina L; Sangoi, Maximiliano S; Fröehlich, Pedro Eduardo; Bergold, Ana Maria

    2012-01-01

    A simple capillary zone electrophoresis (CZE) method was developed and validated for the analysis of lodenafil carbonate in tablets. Response surface methodology was used for optimization of the pH and concentration of the buffer, applied voltage and temperature. The method employed 50 mmol L-1 borate buffer at pH 10 as background electrolyte with an applied voltage of 15 kV. The separation was carried out in a fused-silica capillary maintained at 32.5 ºC and the detection wavelength was 214 ...

  2. Optimization and validation of a method using UHPLC-fluorescence for the analysis of polycyclic aromatic hydrocarbons in cold-pressed vegetable oils.

    Science.gov (United States)

    Silva, Simone Alves da; Sampaio, Geni Rodrigues; Torres, Elizabeth Aparecida Ferraz da Silva

    2017-04-15

    Among the different food categories, the oils and fats are important sources of exposure to polycyclic aromatic hydrocarbons (PAHs), a group of organic chemical contaminants. The use of a validated method is essential to obtain reliable analytical results since the legislation establishes maximum limits in different foods. The objective of this study was to optimize and validate a method for the quantification of four PAHs [benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(a)pyrene] in vegetable oils. The samples were submitted to liquid-liquid extraction, followed by solid-phase extraction, and analyzed by ultra-high performance liquid chromatography. Under the optimized conditions, the validation parameters were evaluated according to the INMETRO Guidelines: linearity (r2 >0.99), selectivity (no matrix interference), limits of detection (0.08-0.30μgkg -1 ) and quantification (0.25-1.00μgkg -1 ), recovery (80.13-100.04%), repeatability and intermediate precision (analysis of PAHs in the vegetable oils evaluated. Copyright © 2016. Published by Elsevier Ltd.

  3. Validation of high-performance liquid chromatography (HPLC method for quantitative analysis of histamine in fish and fishery products

    Directory of Open Access Journals (Sweden)

    B.K.K.K. Jinadasa

    2016-12-01

    Full Text Available A high-performance liquid chromatography method is described for quantitative determination and validation of histamine in fish and fishery product samples. Histamine is extracted from fish/fishery products by homogenizing with tri-chloro acetic acid, separated with Amberlite CG-50 resin and C18-ODS Hypersil reversed phase column at ambient temperature (25°C. Linear standard curves with high correlation coefficients were obtained. An isocratic elution program was used; the total elution time was 10 min. The method was validated by assessing the following aspects; specificity, repeatability, reproducibility, linearity, recovery, limits of detection, limit of quantification and uncertainty. The validated parameters are in good agreement with method and it is a useful tool for determining histamine in fish and fishery products.

  4. CosmoQuest:Using Data Validation for More Than Just Data Validation

    Science.gov (United States)

    Lehan, C.; Gay, P.

    2016-12-01

    It is often taken for granted that different scientists completing the same task (e.g. mapping geologic features) will get the same results, and data validation is often skipped or under-utilized due to time and funding constraints. Robbins et. al (2014), however, demonstrated that this is a needed step, as large variation can exist even among collaborating team members completing straight-forward tasks like marking craters. Data Validation should be much more than a simple post-project verification of results. The CosmoQuest virtual research facility employs regular data-validation for a variety of benefits, including real-time user feedback, real-time tracking to observe user activity while it's happening, and using pre-solved data to analyze users' progress and to help them retain skills. Some creativity in this area can drastically improve project results. We discuss methods of validating data in citizen science projects and outline the variety of uses for validation, which, when used properly, improves the scientific output of the project and the user experience for the citizens doing the work. More than just a tool for scientists, validation can assist users in both learning and retaining important information and skills, improving the quality and quantity of data gathered. Real-time analysis of user data can give key information in the effectiveness of the project that a broad glance would miss, and properly presenting that analysis is vital. Training users to validate their own data, or the data of others, can significantly improve the accuracy of misinformed or novice users.

  5. A Method of Retrospective Computerized System Validation for Drug Manufacturing Software Considering Modifications

    Science.gov (United States)

    Takahashi, Masakazu; Fukue, Yoshinori

    This paper proposes a Retrospective Computerized System Validation (RCSV) method for Drug Manufacturing Software (DMSW) that relates to drug production considering software modification. Because DMSW that is used for quality management and facility control affects big impact to quality of drugs, regulatory agency required proofs of adequacy for DMSW's functions and performance based on developed documents and test results. Especially, the work that explains adequacy for previously developed DMSW based on existing documents and operational records is called RCSV. When modifying RCSV conducted DMSW, it was difficult to secure consistency between developed documents and test results for modified DMSW parts and existing documents and operational records for non-modified DMSW parts. This made conducting RCSV difficult. In this paper, we proposed (a) definition of documents architecture, (b) definition of descriptive items and levels in the documents, (c) management of design information using database, (d) exhaustive testing, and (e) integrated RCSV procedure. As a result, we could conduct adequate RCSV securing consistency.

  6. Using qualitative methods to improve questionnaires for Spanish speakers: assessing face validity of a food behavior checklist.

    Science.gov (United States)

    Banna, Jinan C; Vera Becerra, Luz E; Kaiser, Lucia L; Townsend, Marilyn S

    2010-01-01

    Development of outcome measures relevant to health nutrition behaviors requires a rigorous process of testing and revision. Whereas researchers often report performance of quantitative data collection to assess questionnaire validity and reliability, qualitative testing procedures are often overlooked. This report outlines a procedure for assessing face validity of a Spanish-language dietary assessment tool. Reviewing the literature produced no rigorously validated Spanish-language food behavior assessment tools for the US Department of Agriculture's food assistance and education programs. In response to this need, this study evaluated the face validity of a Spanish-language food behavior checklist adapted from a 16-item English version of a food behavior checklist shown to be valid and reliable for limited-resource English speakers. The English version was translated using rigorous methods involving initial translation by one party and creation of five possible versions. Photos were modified based on client input and new photos were taken as necessary. A sample of low-income, Spanish-speaking women completed cognitive interviews (n=20). Spanish translation experts (n=7) fluent in both languages and familiar with both cultures made minor modifications but essentially approved client preferences. The resulting checklist generated a readability score of 93, indicating low reading difficulty. The Spanish-language checklist has adequate face validity in the target population and is ready for further validation using convergent measures. At the conclusion of testing, this instrument may be used to evaluate nutrition education interventions in California. These qualitative procedures provide a framework for designing evaluation tools for low-literate audiences participating in the US Department of Agriculture food assistance and education programs. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  7. Advanced validation of CFD-FDTD combined method using highly applicable solver for reentry blackout prediction

    International Nuclear Information System (INIS)

    Takahashi, Yusuke

    2016-01-01

    An analysis model of plasma flow and electromagnetic waves around a reentry vehicle for radio frequency blackout prediction during aerodynamic heating was developed in this study. The model was validated based on experimental results from the radio attenuation measurement program. The plasma flow properties, such as electron number density, in the shock layer and wake region were obtained using a newly developed unstructured grid solver that incorporated real gas effect models and could treat thermochemically non-equilibrium flow. To predict the electromagnetic waves in plasma, a frequency-dependent finite-difference time-domain method was used. Moreover, the complicated behaviour of electromagnetic waves in the plasma layer during atmospheric reentry was clarified at several altitudes. The prediction performance of the combined model was evaluated with profiles and peak values of the electron number density in the plasma layer. In addition, to validate the models, the signal losses measured during communication with the reentry vehicle were directly compared with the predicted results. Based on the study, it was suggested that the present analysis model accurately predicts the radio frequency blackout and plasma attenuation of electromagnetic waves in plasma in communication. (paper)

  8. 42 CFR 476.94 - Notice of QIO initial denial determination and changes as a result of a DRG validation.

    Science.gov (United States)

    2010-10-01

    ... changes as a result of a DRG validation. 476.94 Section 476.94 Public Health CENTERS FOR MEDICARE... changes as a result of a DRG validation. (a) Notice of initial denial determination—(1) Parties to be... retrospective review, (excluding DRG validation and post procedure review), within 3 working days of the initial...

  9. Validated method for the analysis of goji berry, a rich source of zeaxanthin dipalmitate.

    Science.gov (United States)

    Karioti, Anastasia; Bergonzi, Maria Camilla; Vincieri, Franco F; Bilia, Anna Rita

    2014-12-31

    In the present study an HPLC-DAD method was developed for the determination of the main carotenoid, zeaxanthin dipalmitate, in the fruits of Lycium barbarum. The aim was to develop and optimize an extraction protocol to allow fast, exhaustive, and repeatable extraction, suitable for labile carotenoid content. Use of liquid N2 allowed the grinding of the fruit. A step of ultrasonication with water removed efficiently the polysaccharides and enabled the exhaustive extraction of carotenoids by hexane/acetone 50:50. The assay was fast and simple and permitted the quality control of a large number of commercial samples including fruits, juices, and a jam. The HPLC method was validated according to ICH guidelines and satisfied the requirements. Finally, the overall method was validated for precision (% RSD ranging between 3.81 and 4.13) and accuracy at three concentration levels. The recovery was between 94 and 107% with RSD values <2%, within the acceptable limits, especially if the difficulty of the matrix is taken into consideration.

  10. Validation of leaf ozone symptoms in natural vegetation using microscopical methods

    International Nuclear Information System (INIS)

    Vollenweider, P.; Ottiger, M.; Guenthardt-Goerg, M.S

    2003-01-01

    Integration of markers of oxidative stress, from the subcellular to the leaf and needle level, proved to be a useful tool for the differential diagnosis and validation of ozone injury. - Ozone injury to natural vegetation is being increasingly surveyed throughout the northern hemisphere. There exists a growing list of species showing visible 'ozone-like' symptoms which needs to be validated. This study presents the results from a test survey of ozone injury to forest vegetation in the light exposed sites of five Swiss level II plots, for the new ICP-Forests protocol. With AOT40 from 14 to 28 ppm·h in 2000, ten out of 49 woody plant species displayed typical symptoms, and four showed untypical symptoms. Symptom origin was investigated in nine and validated in seven species, using morphological, histological and cellular markers of oxidative stress and ozone-induced plant response. Independent of taxonomic position, ozone effects were characterized by the induction of oxidative stress in the mesophyll resulting in discrete and light-dependent hypersensitive-like responses and in accelerated cell senescence. The presented combination of cellular and morphological markers allows differential diagnosis of visible ozone injury

  11. A validated HPTLC method for estimation of moxifloxacin hydrochloride in tablets.

    Science.gov (United States)

    Dhillon, Vandana; Chaudhary, Alok Kumar

    2010-10-01

    A simple HPTLC method having high accuracy, precision and reproducibility was developed for the routine estimation of moxifloxacin hydrochloride in the tablets available in market and was validated for various parameters according to ICH guidelines. moxifloxacin hydrochloride was estimated at 292 nm by densitometry using Silica gel 60 F254 as stationary phase and a premix of methylene chloride: methanol: strong ammonia solution and acetonitrile (10:10:5:10) as mobile phase. Method was found linear in a range of 9-54 nanograms with a correlation coefficient >0.99. The regression equation was: AUC = 65.57 × (Amount in nanograms) + 163 (r(2) = 0.9908).

  12. Review of seismic tests for qualification of components and validation of methods

    International Nuclear Information System (INIS)

    Buland, P.; Gantenbein, F.; Gibert, R.J.; Hoffmann, A.; Queval, J.C.

    1988-01-01

    Seismic tests are performed in CEA-DEMT since many years in order: to demonstrate the qualification of components, to give an experimental validation of calculation methods used for seismic design of components. The paper presents examples of these two types of tests, a description of the existing facilities and details about the new facility TAMARIS under construction. (author)

  13. Review of seismic tests for qualification of components and validation of methods

    Energy Technology Data Exchange (ETDEWEB)

    Buland, P; Gantenbein, F; Gibert, R J; Hoffmann, A; Queval, J C [CEA-CEN SACLAY-DEMT, Gif sur Yvette-Cedex (France)

    1988-07-01

    Seismic tests are performed in CEA-DEMT since many years in order: to demonstrate the qualification of components, to give an experimental validation of calculation methods used for seismic design of components. The paper presents examples of these two types of tests, a description of the existing facilities and details about the new facility TAMARIS under construction. (author)

  14. A statistical method (cross-validation) for bone loss region detection after spaceflight

    Science.gov (United States)

    Zhao, Qian; Li, Wenjun; Li, Caixia; Chu, Philip W.; Kornak, John; Lang, Thomas F.

    2010-01-01

    Astronauts experience bone loss after the long spaceflight missions. Identifying specific regions that undergo the greatest losses (e.g. the proximal femur) could reveal information about the processes of bone loss in disuse and disease. Methods for detecting such regions, however, remains an open problem. This paper focuses on statistical methods to detect such regions. We perform statistical parametric mapping to get t-maps of changes in images, and propose a new cross-validation method to select an optimum suprathreshold for forming clusters of pixels. Once these candidate clusters are formed, we use permutation testing of longitudinal labels to derive significant changes. PMID:20632144

  15. Two Validated HPLC Methods for the Quantification of Alizarin and other Anthraquinones in Rubia tinctorum Cultivars

    NARCIS (Netherlands)

    Derksen, G.C.H.; Lelyveld, G.P.; Beek, van T.A.; Capelle, A.; Groot, de Æ.

    2004-01-01

    Direct and indirect HPLC-UV methods for the quantitative determination of anthraquinones in dried madder root have been developed, validated and compared. In the direct method, madder root was extracted twice with refluxing ethanol-water. This method allowed the determination of the two major native

  16. Content validity and its estimation

    Directory of Open Access Journals (Sweden)

    Yaghmale F

    2003-04-01

    Full Text Available Background: Measuring content validity of instruments are important. This type of validity can help to ensure construct validity and give confidence to the readers and researchers about instruments. content validity refers to the degree that the instrument covers the content that it is supposed to measure. For content validity two judgments are necessary: the measurable extent of each item for defining the traits and the set of items that represents all aspects of the traits. Purpose: To develop a content valid scale for assessing experience with computer usage. Methods: First a review of 2 volumes of International Journal of Nursing Studies, was conducted with onlyI article out of 13 which documented content validity did so by a 4-point content validity index (CV! and the judgment of 3 experts. Then a scale with 38 items was developed. The experts were asked to rate each item based on relevance, clarity, simplicity and ambiguity on the four-point scale. Content Validity Index (CVI for each item was determined. Result: Of 38 items, those with CVIover 0.75 remained and the rest were discarded reSulting to 25-item scale. Conclusion: Although documenting content validity of an instrument may seem expensive in terms of time and human resources, its importance warrants greater attention when a valid assessment instrument is to be developed. Keywords: Content Validity, Measuring Content Validity

  17. Optimization and Validation of Quantitative Spectrophotometric Methods for the Determination of Alfuzosin in Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    M. Vamsi Krishna

    2007-01-01

    Full Text Available Three accurate, simple and precise spectrophotometric methods for the determination of alfuzosin hydrochloride in bulk drugs and tablets are developed. The first method is based on the reaction of alfuzosin with ninhydrin reagent in N, N'-dimethylformamide medium (DMF producing a colored product which absorbs maximally at 575 nm. Beer’s law is obeyed in the concentration range 12.5-62.5 µg/mL of alfuzosin. The second method is based on the reaction of drug with ascorbic acid in DMF medium resulting in the formation of a colored product, which absorbs maximally at 530 nm. Beer’s law is obeyed in the concentration 10-50 µg/mL of alfuzosin. The third method is based on the reaction of alfuzosin with p-benzoquinone (PBQ to form a colored product with λmax at 400 nm. The products of the reaction were stable for 2 h at room temperature. The optimum experimental parameters for the reactions have been studied. The validity of the described procedures was assessed. Statistical analysis of the results has been carried out revealing high accuracy and good precision. The proposed methods could be used for the determination of alfuzosin in pharmaceutical formulations. The procedures were rapid, simple and suitable for quality control application.

  18. Development and validation of a simple and robust method for arsenic speciation in human urine using HPLC/ICP-MS.

    Science.gov (United States)

    Sen, Indranil; Zou, Wei; Alvaran, Josephine; Nguyen, Linda; Gajek, Ryszard; She, Jianwen

    2015-01-01

    In order to better distinguish the different toxic inorganic and organic forms of arsenic (As) exposure in individuals, we have developed and validated a simple and robust analytical method for determining the following six As species in human urine: arsenous (III) acid (As-III), As (V) acid, monomethylarsonic acid, dimethylarsinic acid, arsenobetaine (AsB), and arsenocholine. In this method, human urine is diluted using a pH 5.8 buffer, separation is performed using an anion exchange column with isocratic HPLC, and detection is achieved using inductively coupled plasma-MS. The method uses a single mobile phase consisting of low concentrations of both phosphate buffer (5 mM) and ammonium nitrate salt (5 mM) at pH 9.0; this minimizes the column equilibration time and overcomes challenges with separation between AsB and As-III. In addition, As-III oxidation is prevented by degassing the sample preparation buffer at pH 5.8, degassing the mobile phase online at pH 9.0, and by the use of low temperature (-70 °C) and flip-cap airtight tubes for long term storage of samples. The method was validated using externally provided reference samples. Results were in agreement with target values at varying concentrations and successfully passed external performance test criteria. Internal QC samples were prepared and repeatedly analyzed to assess the method's long-term precision, and further analyses were completed on anonymous donor urine to assess the quality of the method's baseline separation. Results from analyses of external reference samples agreed with target values at varying concentrations, and results from precision studies yielded absolute CV values of 3-14% and recovery from 82 to 115% for the six As species. Analysis of anonymous donor urine confirmed the well-resolved baseline separation capabilities of the method for real participant samples.

  19. A systematic review of validated methods to capture acute bronchospasm using administrative or claims data.

    Science.gov (United States)

    Sharifi, Mona; Krishanswami, Shanthi; McPheeters, Melissa L

    2013-12-30

    To identify and assess billing, procedural, or diagnosis code, or pharmacy claim-based algorithms used to identify acute bronchospasm in administrative and claims databases. We searched the MEDLINE database from 1991 to September 2012 using controlled vocabulary and key terms related to bronchospasm, wheeze and acute asthma. We also searched the reference lists of included studies. Two investigators independently assessed the full text of studies against pre-determined inclusion criteria. Two reviewers independently extracted data regarding participant and algorithm characteristics. Our searches identified 677 citations of which 38 met our inclusion criteria. In these 38 studies, the most commonly used ICD-9 code was 493.x. Only 3 studies reported any validation methods for the identification of bronchospasm, wheeze or acute asthma in administrative and claims databases; all were among pediatric populations and only 2 offered any validation statistics. Some of the outcome definitions utilized were heterogeneous and included other disease based diagnoses, such as bronchiolitis and pneumonia, which are typically of an infectious etiology. One study offered the validation of algorithms utilizing Emergency Department triage chief complaint codes to diagnose acute asthma exacerbations with ICD-9 786.07 (wheezing) revealing the highest sensitivity (56%), specificity (97%), PPV (93.5%) and NPV (76%). There is a paucity of studies reporting rigorous methods to validate algorithms for the identification of bronchospasm in administrative data. The scant validated data available are limited in their generalizability to broad-based populations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Development and validation of NIR-chemometric methods for chemical and pharmaceutical characterization of meloxicam tablets.

    Science.gov (United States)

    Tomuta, Ioan; Iovanov, Rares; Bodoki, Ede; Vonica, Loredana

    2014-04-01

    Near-Infrared (NIR) spectroscopy is an important component of a Process Analytical Technology (PAT) toolbox and is a key technology for enabling the rapid analysis of pharmaceutical tablets. The aim of this research work was to develop and validate NIR-chemometric methods not only for the determination of active pharmaceutical ingredients content but also pharmaceutical properties (crushing strength, disintegration time) of meloxicam tablets. The development of the method for active content assay was performed on samples corresponding to 80%, 90%, 100%, 110% and 120% of meloxicam content and the development of the methods for pharmaceutical characterization was performed on samples prepared at seven different compression forces (ranging from 7 to 45 kN) using NIR transmission spectra of intact tablets and PLS as a regression method. The results show that the developed methods have good trueness, precision and accuracy and are appropriate for direct active content assay in tablets (ranging from 12 to 18 mg/tablet) and also for predicting crushing strength and disintegration time of intact meloxicam tablets. The comparative data show that the proposed methods are in good agreement with the reference methods currently used for the characterization of meloxicam tablets (HPLC-UV methods for the assay and European Pharmacopeia methods for determining the crushing strength and disintegration time). The results show the possibility to predict both chemical properties (active content) and physical/pharmaceutical properties (crushing strength and disintegration time) directly, without any sample preparation, from the same NIR transmission spectrum of meloxicam tablets.

  1. Development and Validation of a Precise and Stability Indicating LC Method for the Determination of Benzalkonium Chloride in Pharmaceutical Formulation Using an Experimental Design

    Directory of Open Access Journals (Sweden)

    Harshal K. Trivedi

    2010-01-01

    Full Text Available A simple, precise, shorter runtime and stability indicating reverse-phase high performance liquid chromatographic method has been developed and validated for the quantification of benzalkonium chloride (BKC preservative in pharmaceutical formulation of sparfloxacin eye drop. The method was successfully applied for determination of benzalkonium chloride in various ophthalmic formulations like latanoprost, timolol, dexametasone, gatifloxacin, norfloxacin, combination of moxifloxacin and dexamethasone, combination of nepthazoline HCl, zinc sulphate and chlorpheniramine maleate, combination of tobaramycin and dexamethasone, combination of phenylephrine HCl, naphazoline HCl, menthol and camphor. The RP-LC separation was achieved on an Purospher Star RP-18e 75 mm × 4.0 mm, 3.0 μ in the isocratic mode using buffer: acetonitrile (35: 65, v/v, as the mobile phase at a flow rate of 1.8 mL/min. The methods were performed at 215 nm; in LC method, quantification was achieved with PDA detection over the concentration range of 50 to 150 μg/mL. The method is effective to separate four homologs with good resolution in presence of excipients, sparfloxacin and degradable compound due to sparfloxacin and BKC within five minutes. The method was validated and the results were compared statistically. They were found to be simple, accurate, precise and specific. The proposed method was validated in terms of specificity, precision, recovery, solution stability, linearity and range. All the validation parameters were within the acceptance range and concordant to ICH guidelines.

  2. Evaluation of bone formation in calcium phosphate scaffolds with μCT-method validation using SEM.

    Science.gov (United States)

    Lewin, S; Barba, A; Persson, C; Franch, J; Ginebra, M-P; Öhman-Mägi, C

    2017-10-05

    There is a plethora of calcium phosphate (CaP) scaffolds used as synthetic substitutes to bone grafts. The scaffold performance is often evaluated from the quantity of bone formed within or in direct contact with the scaffold. Micro-computed tomography (μCT) allows three-dimensional evaluation of bone formation inside scaffolds. However, the almost identical x-ray attenuation of CaP and bone obtrude the separation of these phases in μCT images. Commonly, segmentation of bone in μCT images is based on gray scale intensity, with manually determined global thresholds. However, image analysis methods, and methods for manual thresholding in particular, lack standardization and may consequently suffer from subjectivity. The aim of the present study was to provide a methodological framework for addressing these issues. Bone formation in two types of CaP scaffold architectures (foamed and robocast), obtained from a larger animal study (a 12 week canine animal model) was evaluated by μCT. In addition, cross-sectional scanning electron microscopy (SEM) images were acquired as references to determine thresholds and to validate the result. μCT datasets were registered to the corresponding SEM reference. Global thresholds were then determined by quantitatively correlating the different area fractions in the μCT image, towards the area fractions in the corresponding SEM image. For comparison, area fractions were also quantified using global thresholds determined manually by two different approaches. In the validation the manually determined thresholds resulted in large average errors in area fraction (up to 17%), whereas for the evaluation using SEM references, the errors were estimated to be less than 3%. Furthermore, it was found that basing the thresholds on one single SEM reference gave lower errors than determining them manually. This study provides an objective, robust and less error prone method to determine global thresholds for the evaluation of bone formation in

  3. Development and Validation of Liquid Chromatographic Method for Estimation of Naringin in Nanoformulation

    Directory of Open Access Journals (Sweden)

    Kranti P. Musmade

    2014-01-01

    Full Text Available A simple, precise, accurate, rapid, and sensitive reverse phase high performance liquid chromatography (RP-HPLC method with UV detection has been developed and validated for quantification of naringin (NAR in novel pharmaceutical formulation. NAR is a polyphenolic flavonoid present in most of the citrus plants having variety of pharmacological activities. Method optimization was carried out by considering the various parameters such as effect of pH and column. The analyte was separated by employing a C18 (250.0 × 4.6 mm, 5 μm column at ambient temperature in isocratic conditions using phosphate buffer pH 3.5: acetonitrile (75 : 25% v/v as mobile phase pumped at a flow rate of 1.0 mL/min. UV detection was carried out at 282 nm. The developed method was validated according to ICH guidelines Q2(R1. The method was found to be precise and accurate on statistical evaluation with a linearity range of 0.1 to 20.0 μg/mL for NAR. The intra- and interday precision studies showed good reproducibility with coefficients of variation (CV less than 1.0%. The mean recovery of NAR was found to be 99.33 ± 0.16%. The proposed method was found to be highly accurate, sensitive, and robust. The proposed liquid chromatographic method was successfully employed for the routine analysis of said compound in developed novel nanopharmaceuticals. The presence of excipients did not show any interference on the determination of NAR, indicating method specificity.

  4. Global approach for the validation of an in-line Raman spectroscopic method to determine the API content in real-time during a hot-melt extrusion process.

    Science.gov (United States)

    Netchacovitch, L; Thiry, J; De Bleye, C; Dumont, E; Cailletaud, J; Sacré, P-Y; Evrard, B; Hubert, Ph; Ziemons, E

    2017-08-15

    Since the Food and Drug Administration (FDA) published a guidance based on the Process Analytical Technology (PAT) approach, real-time analyses during manufacturing processes are in real expansion. In this study, in-line Raman spectroscopic analyses were performed during a Hot-Melt Extrusion (HME) process to determine the Active Pharmaceutical Ingredient (API) content in real-time. The method was validated based on a univariate and a multivariate approach and the analytical performances of the obtained models were compared. Moreover, on one hand, in-line data were correlated with the real API concentration present in the sample quantified by a previously validated off-line confocal Raman microspectroscopic method. On the other hand, in-line data were also treated in function of the concentration based on the weighing of the components in the prepared mixture. The importance of developing quantitative methods based on the use of a reference method was thus highlighted. The method was validated according to the total error approach fixing the acceptance limits at ±15% and the α risk at ±5%. This method reaches the requirements of the European Pharmacopeia norms for the uniformity of content of single-dose preparations. The validation proves that future results will be in the acceptance limits with a previously defined probability. Finally, the in-line validated method was compared with the off-line one to demonstrate its ability to be used in routine analyses. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Development and Validation of HPLC-DAD and UHPLC-DAD Methods for the Simultaneous Determination of Guanylhydrazone Derivatives Employing a Factorial Design.

    Science.gov (United States)

    Azevedo de Brito, Wanessa; Gomes Dantas, Monique; Andrade Nogueira, Fernando Henrique; Ferreira da Silva-Júnior, Edeildo; Xavier de Araújo-Júnior, João; Aquino, Thiago Mendonça de; Adélia Nogueira Ribeiro, Êurica; da Silva Solon, Lilian Grace; Soares Aragão, Cícero Flávio; Barreto Gomes, Ana Paula

    2017-08-30

    Guanylhydrazones are molecules with great pharmacological potential in various therapeutic areas, including antitumoral activity. Factorial design is an excellent tool in the optimization of a chromatographic method, because it is possible quickly change factors such as temperature, mobile phase composition, mobile phase pH, column length, among others to establish the optimal conditions of analysis. The aim of the present work was to develop and validate a HPLC and UHPLC methods for the simultaneous determination of guanylhydrazones with anticancer activity employing experimental design. Precise, exact, linear and robust HPLC and UHPLC methods were developed and validated for the simultaneous quantification of the guanylhydrazones LQM10, LQM14, and LQM17. The UHPLC method was more economic, with a four times less solvent consumption, and 20 times less injection volume, what allowed better column performance. Comparing the empirical approach employed in the HPLC method development to the DoE approach employed in the UHPLC method development, we can conclude that the factorial design made the method development faster, more practical and rational. This resulted in methods that can be employed in the analysis, evaluation and quality control of these new synthetic guanylhydrazones.

  6. [Development and validation of event-specific quantitative PCR method for genetically modified maize LY038].

    Science.gov (United States)

    Mano, Junichi; Masubuchi, Tomoko; Hatano, Shuko; Futo, Satoshi; Koiwa, Tomohiro; Minegishi, Yasutaka; Noguchi, Akio; Kondo, Kazunari; Akiyama, Hiroshi; Teshima, Reiko; Kurashima, Takeyo; Takabatake, Reona; Kitta, Kazumi

    2013-01-01

    In this article, we report a novel real-time PCR-based analytical method for quantitation of the GM maize event LY038. We designed LY038-specific and maize endogenous reference DNA-specific PCR amplifications. After confirming the specificity and linearity of the LY038-specific PCR amplification, we determined the conversion factor required to calculate the weight-based content of GM organism (GMO) in a multilaboratory evaluation. Finally, in order to validate the developed method, an interlaboratory collaborative trial according to the internationally harmonized guidelines was performed with blind DNA samples containing LY038 at the mixing levels of 0, 0.5, 1.0, 5.0 and 10.0%. The precision of the method was evaluated as the RSD of reproducibility (RSDR), and the values obtained were all less than 25%. The limit of quantitation of the method was judged to be 0.5% based on the definition of ISO 24276 guideline. The results from the collaborative trial suggested that the developed quantitative method would be suitable for practical testing of LY038 maize.

  7. Validation of a Novel 3-Dimensional Sonographic Method for Assessing Gastric Accommodation in Healthy Adults

    NARCIS (Netherlands)

    Buisman, Wijnand J; van Herwaarden-Lindeboom, MYA; Mauritz, Femke A; El Ouamari, Mourad; Hausken, Trygve; Olafsdottir, Edda J; van der Zee, David C; Gilja, Odd Helge

    OBJECTIVES: A novel automated 3-dimensional (3D) sonographic method has been developed for measuring gastric volumes. This study aimed to validate and assess the reliability of this novel 3D sonographic method compared to the reference standard in 3D gastric sonography: freehand magneto-based 3D

  8. A Rapid, Simple, and Validated RP-HPLC Method for Quantitative Analysis of Levofloxacin in Human Plasma

    Directory of Open Access Journals (Sweden)

    Dion Notario

    2017-04-01

    Full Text Available To conduct a bioequivalence study for a copy product of levofloxacin (LEV, a simple and validated analytical method was needed, but the previous developed methods were still too complicated. For this reason, a simple and rapid high performance liquid chromatography method was developed and validated for LEV quantification in human plasma. Chromatographic separation was performed under isocratic elution on a Luna Phenomenex® C18 (150 × 4.6 mm, 5 µm column. The mobile phase was comprised of acetonitrile, methanol, and phosphate buffer 25 mM that adjusted at pH 3.0 (13:7:80 v/v/v and pumped at a flow rate of 1.5 mL/min. Detection was performed under UV detector at wavelength of 280 nm. Samples were prepared by adding acetonitrile and followed by centrifugation to precipitate plasma protein. Then followed successively by evaporation and reconstitution step. The optimized method meets the requirements of validation parameters which included linearity (r = 0.995, sensitivity (LLOQ and LOD was 1.77 and 0.57 µg/mL respectively, accuracy (%error above LLOQ ≤ 12% and LLOQ ≤ 20%, precision (RSD ≤ 9%, and robustness in the ranges of 1.77-28.83 µg/mL. Therefore, the method can be used as a routine analysis of LEV in human plasma as well as in bioequivalence study of LEV.

  9. Evaluation of passenger health risk assessment of sustainable indoor air quality monitoring in metro systems based on a non-Gaussian dynamic sensor validation method.

    Science.gov (United States)

    Kim, MinJeong; Liu, Hongbin; Kim, Jeong Tai; Yoo, ChangKyoo

    2014-08-15

    Sensor faults in metro systems provide incorrect information to indoor air quality (IAQ) ventilation systems, resulting in the miss-operation of ventilation systems and adverse effects on passenger health. In this study, a new sensor validation method is proposed to (1) detect, identify and repair sensor faults and (2) evaluate the influence of sensor reliability on passenger health risk. To address the dynamic non-Gaussianity problem of IAQ data, dynamic independent component analysis (DICA) is used. To detect and identify sensor faults, the DICA-based squared prediction error and sensor validity index are used, respectively. To restore the faults to normal measurements, a DICA-based iterative reconstruction algorithm is proposed. The comprehensive indoor air-quality index (CIAI) that evaluates the influence of the current IAQ on passenger health is then compared using the faulty and reconstructed IAQ data sets. Experimental results from a metro station showed that the DICA-based method can produce an improved IAQ level in the metro station and reduce passenger health risk since it more accurately validates sensor faults than do conventional methods. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Development and Validation of a HPLC-UV Method for Extraction Optimization and Biological Evaluation of Hot-Water and Ethanolic Extracts of Dendropanax morbifera Leaves

    Directory of Open Access Journals (Sweden)

    Hyung-Jae Choi

    2018-03-01

    Full Text Available Dendropanax morbifera Leveille (Araliaceae has been used in traditional oriental remedies for cancer, inflammation, diabetes, and thrombosis. However, a validated analytical method, standardization, and optimization of extraction conditions with respect to biological activity have not been reported. In this study, a simple and validated HPLC method for identifying and quantifying active substances in D. morbifera was developed. Hot water and ethanolic D. morbifera leaf extracts from different production regions were prepared and evaluated with regard to their chemical compositions and biological activities. The contents of active compounds such as rutin and chlorogenic acid were determined in four samples collected from different regions. The 80% ethanolic extract showed the best antioxidant activity, phenolic content, reducing power, and xanthine oxidase (XO inhibitory activity. The validated HPLC method confirmed the presence of chlorogenic acid and rutin in D. morbifera leaf extracts. The antioxidant and XO inhibitory activity of D. morbifera extract could be attributed to the marker compounds. Collectively, these results suggest that D. morbifera leaves could be beneficial for the treatment or prevention of hyperuricemia-related disease, and the validated HPLC method could be a useful tool for the quality control of food or drug formulations containing D. morbifera.

  11. A validated RP-HPLC method for simultaneous determination of propranolol and valsartan in bulk drug and gel formulation

    Science.gov (United States)

    Imam, Syed Sarim; Ahad, Abdul; Aqil, Mohammed; Sultana, Yasmin; Ali, Asgar

    2013-01-01

    Objective: A simple, precise, and stability indicating high performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of propranolol hydrochloride and valsartan in pharmaceutical dosage form. Materials and Methods: The method involves the use of easily available inexpensive laboratory reagents. The separation was achieved on Hypersil ODS C-18 column (250*4.6 mm, i.d., 5 μm particle size) with isocratic flow with UV detector. The mobile phase at a flow rate of 1.0 mL/min consisted of acetonitrile, methanol, and 0.01 M disodium hydrogen phosphate (pH 3.5) in the ratio of 50:35:15 v/v. Results: A linear response was observed over the concentration range 5-50 μg/mL of propranolol and the concentration range 4-32 μg/mL of valsartan. Limit of detection and limit of quantitation for propranolol were 0.27 μg/mL and 0.85 μg/mL, and for valsartan were 0.45 μg/mL and 1.39 μg/mL, respectively. The method was successfully validated in accordance to ICH guidelines acceptance criteria for linearity, accuracy, precision, specificity, robustness. Conclusion: The analysis concluded that the method was selective for simultaneous estimation of propranolol and valsartan can be potentially used for the estimation of these drugs in combined dosage form. PMID:23559826

  12. Likelihood ratio data to report the validation of a forensic fingerprint evaluation method

    NARCIS (Netherlands)

    Ramos, Daniel; Haraksim, Rudolf; Meuwly, Didier

    2017-01-01

    Data to which the authors refer to throughout this article are likelihood ratios (LR) computed from the comparison of 5–12 minutiae fingermarks with fingerprints. These LRs data are used for the validation of a likelihood ratio (LR) method in forensic evidence evaluation. These data present a

  13. Use of reference materials for validating analytical methods. Applied to the determination of As, Co, Na, Hg, Se and Fe using neutron activation analysis

    International Nuclear Information System (INIS)

    Munoz, L; Andonie, O; Kohnenkamp, I

    2000-01-01

    The main purpose of an analytical laboratory is to provide reliable information on the nature and composition of the materials submitted for analysis. This purpose can only be attained if analytical methodologies that have the attributes of accuracy, precision, specificity and sensitivity, among others, are used. The process by which these attributes are evaluated is called validation of the analytical method. The Chilean Nuclear Energy Commission's Neutron Activation Analysis Laboratory is applying a quality guarantee program to ensure the quality of its analytical results, which aims, as well, to attain accreditation for some of its measurements. Validation of the analytical methodologies used is an essential part of applying this program. There are many forms of validation, from comparison with reference techniques to participation in inter-comparison rounds. Certified reference materials were used in this work in order to validate the application of neutron activation analysis in determining As, Co, Na, Hg, Se and Fe in shellfish samples. The use of reference materials was chosen because it is a simple option that easily detects sources of systematic errors. Neutron activation analysis is an instrumental analytical method that does not need chemical treatment and that is based on processes which take place in the nuclei of atoms, making the matrix effects unimportant and different biological reference materials can be used. The following certified reference materials were used for validating the method used: BCR human hair 397, NRCC dogfish muscle DORM-2, NRCC -dogfish liver DOLT-2, NIST - oyster tissue 1566, NIES - mussel 6 and BCR - tuna fish 464. The reference materials were analyzed using the procedure developed for the shellfish samples and the above-mentioned elements were determined. With the results obtained, the parameters of accuracy, precision, detection limit, quantification limit and uncertainty associated with the method were determined for each

  14. TH-CD-202-06: A Method for Characterizing and Validating Dynamic Lung Density Change During Quiet Respiration

    Energy Technology Data Exchange (ETDEWEB)

    Dou, T [University of California, Los Angeles, Los Angeles, CA (United States); Ruan, D [UCLA School of Medicine, Los Angeles, CA (United States); Heinrich, M [Institute of Medical Informatics, University of Lubeck, Lubeck, Schleswig-Holstein (Germany); Low, D [UCLA, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To obtain a functional relationship that calibrates the lung tissue density change under free breathing conditions through correlating Jacobian values to the Hounsfield units. Methods: Free-breathing lung computed tomography images were acquired using a fast helical CT protocol, where 25 scans were acquired per patient. Using a state-of-the-art deformable registration algorithm, a set of the deformation vector fields (DVF) was generated to provide spatial mapping from the reference image geometry to the other free-breathing scans. These DVFs were used to generate Jacobian maps, which estimate voxelwise volume change. Subsequently, the set of 25 corresponding Jacobian and voxel intensity in Hounsfield units (HU) were collected and linear regression was performed based on the mass conservation relationship to correlate the volume change to density change. Based on the resulting fitting coefficients, the tissues were classified into parenchymal (Type I), vascular (Type II), and soft tissue (Type III) types. These coefficients modeled the voxelwise density variation during quiet breathing. The accuracy of the proposed method was assessed using mean absolute difference in HU between the CT scan intensities and the model predicted values. In addition, validation experiments employing a leave-five-out method were performed to evaluate the model accuracy. Results: The computed mean model errors were 23.30±9.54 HU, 29.31±10.67 HU, and 35.56±20.56 HU, respectively, for regions I, II, and III, respectively. The cross validation experiments averaged over 100 trials had mean errors of 30.02 ± 1.67 HU over the entire lung. These mean values were comparable with the estimated CT image background noise. Conclusion: The reported validation experiment statistics confirmed the lung density modeling during free breathing. The proposed technique was general and could be applied to a wide range of problem scenarios where accurate dynamic lung density information is needed

  15. Validation of a Consensus Method for Identifying Delirium from Hospital Records

    Science.gov (United States)

    Kuhn, Elvira; Du, Xinyi; McGrath, Keith; Coveney, Sarah; O'Regan, Niamh; Richardson, Sarah; Teodorczuk, Andrew; Allan, Louise; Wilson, Dan; Inouye, Sharon K.; MacLullich, Alasdair M. J.; Meagher, David; Brayne, Carol; Timmons, Suzanne; Davis, Daniel

    2014-01-01

    Background Delirium is increasingly considered to be an important determinant of trajectories of cognitive decline. Therefore, analyses of existing cohort studies measuring cognitive outcomes could benefit from methods to ascertain a retrospective delirium diagnosis. This study aimed to develop and validate such a method for delirium detection using routine medical records in UK and Ireland. Methods A point prevalence study of delirium provided the reference-standard ratings for delirium diagnosis. Blinded to study results, clinical vignettes were compiled from participants' medical records in a standardised manner, describing any relevant delirium symptoms recorded in the whole case record for the period leading up to case-ascertainment. An expert panel rated each vignette as unlikely, possible, or probable delirium and disagreements were resolved by consensus. Results From 95 case records, 424 vignettes were abstracted by 5 trained clinicians. There were 29 delirium cases according to the reference standard. Median age of subjects was 76.6 years (interquartile range 54.6 to 82.5). Against the original study DSM-IV diagnosis, the chart abstraction method gave a positive likelihood ratio (LR) of 7.8 (95% CI 5.7–12.0) and the negative LR of 0.45 (95% CI 0.40–0.47) for probable delirium (sensitivity 0.58 (95% CI 0.53–0.62); specificity 0.93 (95% CI 0.90–0.95); AUC 0.86 (95% CI 0.82–0.89)). The method diagnosed possible delirium with positive LR 3.5 (95% CI 2.9–4.3) and negative LR 0.15 (95% CI 0.11–0.21) (sensitivity 0.89 (95% CI 0.85–0.91); specificity 0.75 (95% CI 0.71–0.79); AUC 0.86 (95% CI 0.80–0.89)). Conclusions This chart abstraction method can retrospectively diagnose delirium in hospitalised patients with good accuracy. This has potential for retrospectively identifying delirium in cohort studies where routine medical records are available. This example of record linkage between hospitalisations and epidemiological data may lead to

  16. A proactive alarm reduction method and its human factors validation test for a main control room for SMART

    International Nuclear Information System (INIS)

    Jang, Gwi-sook; Suh, Sang-moon; Kim, Sa-kil; Suh, Yong-suk; Park, Je-yun

    2013-01-01

    Highlights: ► A proactive alarm reduction method improves effectiveness on the alarm reduction. ► The method suppresses alarms based on the ECA rules and facts for the alarm reduction under an alarm flood situation. ► The alarm reduction logics are supplemented to a high hit ratio of the reduction logics during on-line operations. ► The method is validated by human factors validation test based on regulatory requirements. -- Abstract: Conventional alarm systems tend to overwhelm operators during a transient because of a large number of nearly simultaneous annunciator activations with varying degrees of relevance to operator tasks. Thus alarm processing techniques have developed to support operators in coping with the volume of alarms, to identify which alarms are significant, and to reduce the need for operators to infer the plant conditions. This paper proposes a proactive alarm reduction method for SMART (System-integrated Modular Advanced ReacTor) whereby based on the contents of the past operating effects alarm reduction is carried out during the next transient. We designed and implemented the proactive alarm reduction system and constructed the environment for the human factors validation test. Also, eight subjects actually working in a nuclear power plant (NPP) tested the practical effectiveness of the proposed proactive alarm reduction method according to the procedure of human factors validation test under a dynamic simulation of a partial scope for an NPP.

  17. European validation of Real-Time PCR method for detection of Salmonella spp. in pork meat.

    Science.gov (United States)

    Delibato, Elisabetta; Rodriguez-Lazaro, David; Gianfranceschi, Monica; De Cesare, Alessandra; Comin, Damiano; Gattuso, Antonietta; Hernandez, Marta; Sonnessa, Michele; Pasquali, Frédérique; Sreter-Lancz, Zuzsanna; Saiz-Abajo, María-José; Pérez-De-Juan, Javier; Butrón, Javier; Prukner-Radovcic, Estella; Horvatek Tomic, Danijela; Johannessen, Gro S; Jakočiūnė, Džiuginta; Olsen, John E; Chemaly, Marianne; Le Gall, Francoise; González-García, Patricia; Lettini, Antonia Anna; Lukac, Maja; Quesne, Segolénè; Zampieron, Claudia; De Santis, Paola; Lovari, Sarah; Bertasi, Barbara; Pavoni, Enrico; Proroga, Yolande T R; Capuano, Federico; Manfreda, Gerardo; De Medici, Dario

    2014-08-01

    The classical microbiological method for detection of Salmonella spp. requires more than five days for final confirmation, and consequently there is a need for an alternative methodology for detection of this pathogen particularly in those food categories with a short shelf-life. This study presents an international (at European level) ISO 16140-based validation study of a non-proprietary Real-Time PCR-based method that can generate final results the day following sample analysis. It is based on an ISO compatible enrichment coupled to an easy and inexpensive DNA extraction and a consolidated Real-Time PCR assay. Thirteen laboratories from seven European Countries participated to this trial, and pork meat was selected as food model. The limit of detection observed was down to 10 CFU per 25 g of sample, showing excellent concordance and accordance values between samples and laboratories (100%). In addition, excellent values were obtained for relative accuracy, specificity and sensitivity (100%) when the results obtained for the Real-Time PCR-based methods were compared to those of the ISO 6579:2002 standard method. The results of this international trial demonstrate that the evaluated Real-Time PCR-based method represents an excellent alternative to the ISO standard. In fact, it shows an equal and solid performance as well as it reduces dramatically the extent of the analytical process, and can be easily implemented routinely by the Competent Authorities and Food Industry laboratories. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Simple Methods for Scanner Drift Normalization Validated for Automatic Segmentation of Knee Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Dam, Erik Bjørnager

    2018-01-01

    Scanner drift is a well-known magnetic resonance imaging (MRI) artifact characterized by gradual signal degradation and scan intensity changes over time. In addition, hardware and software updates may imply abrupt changes in signal. The combined effects are particularly challenging for automatic...... image analysis methods used in longitudinal studies. The implication is increased measurement variation and a risk of bias in the estimations (e.g. in the volume change for a structure). We proposed two quite different approaches for scanner drift normalization and demonstrated the performance...... for segmentation of knee MRI using the fully automatic KneeIQ framework. The validation included a total of 1975 scans from both high-field and low-field MRI. The results demonstrated that the pre-processing method denoted Atlas Affine Normalization significantly removed scanner drift effects and ensured...

  19. An analysis of normalization methods for Drosophila RNAi genomic screens and development of a robust validation scheme

    Science.gov (United States)

    Wiles, Amy M.; Ravi, Dashnamoorthy; Bhavani, Selvaraj; Bishop, Alexander J.R.

    2010-01-01

    Genome-wide RNAi screening is a powerful, yet relatively immature technology that allows investigation into the role of individual genes in a process of choice. Most RNAi screens identify a large number of genes with a continuous gradient in the assessed phenotype. Screeners must then decide whether to examine just those genes with the most robust phenotype or to examine the full gradient of genes that cause an effect and how to identify the candidate genes to be validated. We have used RNAi in Drosophila cells to examine viability in a 384-well plate format and compare two screens, untreated control and treatment. We compare multiple normalization methods, which take advantage of different features within the data, including quantile normalization, background subtraction, scaling, cellHTS2 1, and interquartile range measurement. Considering the false-positive potential that arises from RNAi technology, a robust validation method was designed for the purpose of gene selection for future investigations. In a retrospective analysis, we describe the use of validation data to evaluate each normalization method. While no normalization method worked ideally, we found that a combination of two methods, background subtraction followed by quantile normalization and cellHTS2, at different thresholds, captures the most dependable and diverse candidate genes. Thresholds are suggested depending on whether a few candidate genes are desired or a more extensive systems level analysis is sought. In summary, our normalization approaches and experimental design to perform validation experiments are likely to apply to those high-throughput screening systems attempting to identify genes for systems level analysis. PMID:18753689

  20. Validation of the method for determination of plutonium isotopes in urine samples and its application in a nuclear facility at Otwock

    Directory of Open Access Journals (Sweden)

    Rzemek Katarzyna

    2015-03-01

    Full Text Available The studies aimed at determining low activities of alpha radioactive elements are widely recognized as essential for the human health, because of their high radiotoxicity in case of internal contamination. Some groups of workers of nuclear facility at Otwock are potentially exposed to contamination with plutonium isotopes. For this reason, the method for determination of plutonium isotopes has been introduced and validated in Radiation Protection Measurements Laboratory (LPD of the National Centre for Nuclear Research (NCBJ. In this method the plutonium is isolated from a sample by coprecipitation with phosphates and separated on a AG 1-X2 Resin. After electrodeposition, the sample is measured by alpha spectrometry. Validation was performed in order to assess parameters such as: selectivity, accuracy (trueness and precision and linearity of the method. The results of plutonium determination in urine samples of persons potentially exposed to internal contamination are presented in this work.

  1. Validation and Recommendation of Methods to Measure Biogas Production Potential of Animal Manure

    Directory of Open Access Journals (Sweden)

    C. H. Pham

    2013-06-01

    Full Text Available In developing countries, biogas energy production is seen as a technology that can provide clean energy in poor regions and reduce pollution caused by animal manure. Laboratories in these countries have little access to advanced gas measuring equipment, which may limit research aimed at improving local adapted biogas production. They may also be unable to produce valid estimates of an international standard that can be used for articles published in international peer-reviewed science journals. This study tested and validated methods for measuring total biogas and methane (CH4 production using batch fermentation and for characterizing the biomass. The biochemical methane potential (BMP (CH4 NL kg−1 VS of pig manure, cow manure and cellulose determined with the Moller and VDI methods was not significantly different in this test (p>0.05. The biodegradability using a ratio of BMP and theoretical BMP (TBMP was slightly higher using the Hansen method, but differences were not significant. Degradation rate assessed by methane formation rate showed wide variation within the batch method tested. The first-order kinetics constant k for the cumulative methane production curve was highest when two animal manures were fermented using the VDI 4630 method, indicating that this method was able to reach steady conditions in a shorter time, reducing fermentation duration. In precision tests, the repeatability of the relative standard deviation (RSDr for all batch methods was very low (4.8 to 8.1%, while the reproducibility of the relative standard deviation (RSDR varied widely, from 7.3 to 19.8%. In determination of biomethane concentration, the values obtained using the liquid replacement method (LRM were comparable to those obtained using gas chromatography (GC. This indicates that the LRM method could be used to determine biomethane concentration in biogas in laboratories with limited access to GC.

  2. Method validation for preparing serum and plasma samples from human blood for downstream proteomic, metabolomic, and circulating nucleic acid-based applications.

    Science.gov (United States)

    Ammerlaan, Wim; Trezzi, Jean-Pierre; Lescuyer, Pierre; Mathay, Conny; Hiller, Karsten; Betsou, Fay

    2014-08-01

    Formal method validation for biospecimen processing in the context of accreditation in laboratories and biobanks is lacking. Serum and plasma processing protocols were validated for fitness-for-purpose in terms of key downstream endpoints, and this article demonstrates methodology for biospecimen processing method validation. Serum and plasma preparation from human blood was optimized for centrifugation conditions with respect to microparticle counts. Optimal protocols were validated for methodology and reproducibility in terms of acceptance criteria based on microparticle counts, DNA and hemoglobin concentration, and metabolomic and proteomic profiles. These parameters were also used to evaluate robustness for centrifugation temperature (4°C versus room temperature [RT]), deceleration (low, medium, high) and blood stability (after a 2-hour delay). Optimal protocols were 10-min centrifugation for serum and 20-min for plasma at 2000 g, medium brake, RT. Methodology and reproducibility acceptance criteria were met for both protocols except for reproducibility of plasma metabolomics. Overall, neither protocol was robust for centrifugation at 4°C versus RT. RT gave higher microparticles and free DNA yields in serum, and fewer microparticles with less hemolysis in plasma. Overall, both protocols were robust for fast, medium, and low deceleration, with a medium brake considered optimal. Pre-centrifugation stability after a 2-hour delay was seen at both temperatures for hemoglobin concentration and proteomics, but not for microparticle counts. We validated serum and plasma collection methods suitable for downstream protein, metabolite, or free nucleic acid-based applications. Temperature and pre-centrifugation delay can influence analytic results, and laboratories and biobanks should systematically record these conditions in the scope of accreditation.

  3. Optimization of instrumental neutron activation analysis method by means of 2k experimental design technique aiming the validation of analytical procedures

    International Nuclear Information System (INIS)

    Petroni, Robson; Moreira, Edson G.

    2013-01-01

    In this study optimization of procedures and standardization of Instrumental Neutron Activation Analysis (INAA) methods were carried out for the determination of the elements arsenic, chromium, cobalt, iron, rubidium, scandium, selenium and zinc in biological materials. The aim is to validate the analytical methods for future accreditation at the National Institute of Metrology, Quality and Technology (INMETRO). The 2 k experimental design was applied for evaluation of the individual contribution of selected variables of the analytical procedure in the final mass fraction result. Samples of Mussel Tissue Certified Reference Material and multi-element standards were analyzed considering the following variables: sample decay time, counting time and sample distance to detector. The standard multi-element concentration (comparator standard), mass of the sample and irradiation time were maintained constant in this procedure. By means of the statistical analysis and theoretical and experimental considerations it was determined the optimized experimental conditions for the analytical methods that will be adopted for the validation procedure of INAA methods in the Neutron Activation Analysis Laboratory (LAN) of the Research Reactor Center (CRPq) at the Nuclear and Energy Research Institute (IPEN - CNEN/SP). Optimized conditions were estimated based on the results of z-score tests, main effect and interaction effects. The results obtained with the different experimental configurations were evaluated for accuracy (precision and trueness) for each measurement. (author)

  4. Analysis of progressive distorsion. Validation of the method based on effective primary stress. Discussion of Anderson's experimental data

    International Nuclear Information System (INIS)

    Moulin, Didier.

    1981-02-01

    An empirical rule usable for design by analysis against progressive distorsion has been set up from experiments conducted in C.E.N. Saclay. This rule is checked with experimental data obtained by W.F. ANDERSON, this experiment is sufficiently different from the Saclay one to evaluate the merits of the rule. The satisfactory results achieved, are another validation of the efficiency diagram on which the method is based [fr

  5. Pesticide applicators questionnaire content validation: A fuzzy delphi method.

    Science.gov (United States)

    Manakandan, S K; Rosnah, I; Mohd Ridhuan, J; Priya, R

    2017-08-01

    The most crucial step in forming a set of survey questionnaire is deciding the appropriate items in a construct. Retaining irrelevant items and removing important items will certainly mislead the direction of a particular study. This article demonstrates Fuzzy Delphi method as one of the scientific analysis technique to consolidate consensus agreement within a panel of experts pertaining to each item's appropriateness. This method reduces the ambiguity, diversity, and discrepancy of the opinions among the experts hence enhances the quality of the selected items. The main purpose of this study was to obtain experts' consensus on the suitability of the preselected items on the questionnaire. The panel consists of sixteen experts from the Occupational and Environmental Health Unit of Ministry of Health, Vector-borne Disease Control Unit of Ministry of Health and Occupational and Safety Health Unit of both public and private universities. A set of questionnaires related to noise and chemical exposure were compiled based on the literature search. There was a total of six constructs with 60 items in which three constructs for knowledge, attitude, and practice of noise exposure and three constructs for knowledge, attitude, and practice of chemical exposure. The validation process replicated recent Fuzzy Delphi method that using a concept of Triangular Fuzzy Numbers and Defuzzification process. A 100% response rate was obtained from all the sixteen experts with an average Likert scoring of four to five. Post FDM analysis, the first prerequisite was fulfilled with a threshold value (d) ≤ 0.2, hence all the six constructs were accepted. For the second prerequisite, three items (21%) from noise-attitude construct and four items (40%) from chemical-practice construct had expert consensus lesser than 75%, which giving rise to about 12% from the total items in the questionnaire. The third prerequisite was used to rank the items within the constructs by calculating the average

  6. Validation of an HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface of pharmaceutical manufacturing equipments.

    Science.gov (United States)

    Akl, Magda A; Ahmed, Mona A; Ramadan, Ahmed

    2011-05-15

    In pharmaceutical industry, an important step consists in the removal of possible drug residues from the involved equipments and areas. The cleaning procedures must be validated and methods to determine trace amounts of drugs have, therefore, to be considered with special attention. An HPLC-UV method for the determination of ceftriaxone sodium residues on stainless steel surface was developed and validated in order to control a cleaning procedure. Cotton swabs, moistened with extraction solution (50% water and 50% mobile phase), were used to remove any residues of drugs from stainless steel surfaces, and give recoveries of 91.12, 93.8 and 98.7% for three concentration levels. The precision of the results, reported as the relative standard deviation (RSD), were below 1.5%. The method was validated over a concentration range of 1.15-6.92 μg ml(-1). Low quantities of drug residues were determined by HPLC-UV using a Hypersil ODS 5 μm (250×4.6 mm) at 50 °C with an acetonitrile:water:pH 7:pH 5 (39-55-5.5-0.5) mobile phase at flow rate of 1.5 ml min(-1), an injection volume of 20 μl and were detected at 254 nm. A simple, selective and sensitive HPLC-UV assay for the determination of ceftriaxone sodium residues on stainless steel surfaces was developed, validated and applied. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Validated UV-Spectrophotometric Methods for Determination of Gemifloxacin Mesylate in Pharmaceutical Tablet Dosage Forms

    Directory of Open Access Journals (Sweden)

    R. Rote Ambadas

    2010-01-01

    Full Text Available Two simple, economic and accurate UV spectrophotometric methods have been developed for determination of gemifloxacin mesylate in pharmaceutical tablet formulation. The first UV-spectrophotometric method depends upon the measurement of absorption at the wavelength 263.8 nm. In second area under curve method the wavelength range for detection was selected from 268.5-258.5 nm. Beer’s law was obeyed in the range of 2 to 12 μgmL-1 for both the methods. The proposed methods was validated statistically and applied successfully to determination of gemifloxacin mesylate in pharmaceutical formulation.

  8. Validation of an analytical method for determining halothane in urine as an instrument for evaluating occupational exposure

    International Nuclear Information System (INIS)

    Gonzalez Chamorro, Rita Maria; Jaime Novas, Arelis; Diaz Padron, Heliodora

    2010-01-01

    The occupational exposure to harmful substances may impose the apparition of determined significative changes in the normal physiology of the organism when the adequate security measures are not taken in time in a working place where the risk may be present. Among the chemical risks that may affect the workers' health are the inhalable anesthetic agents. With the objective to take the first steps for the introduction of an epidemiological surveillance system to this personnel, an analytical method for determining this anesthetic in urine was validated with the instrumental conditions created in our laboratory. To carry out this validation the following parameters were taken into account: specificity, lineament, precision, accuracy, detection limit and quantification limit, and the uncertainty of the method was calculated. In the validation procedure it was found that the technique is specific and precise, the detection limit was of 0,118 μg/L, and of the quantification limit of 0,354 μg/L. The global uncertainty was of 0,243, and the expanded of 0,486. The validated method, together with the posterior introduction of the biological exposure limits, will serve as an auxiliary means of diagnosis which will allow us a periodical control of the personnel exposure

  9. Application and validation of superior spectrophotometric methods for simultaneous determination of ternary mixture used for hypertension management

    Science.gov (United States)

    Mohamed, Heba M.; Lamie, Nesrine T.

    2016-02-01

    Telmisartan (TL), Hydrochlorothiazide (HZ) and Amlodipine besylate (AM) are co-formulated together for hypertension management. Three smart, specific and precise spectrophotometric methods were applied and validated for simultaneous determination of the three cited drugs. Method A is the ratio isoabsorptive point and ratio difference in subtracted spectra (RIDSS) which is based on dividing the ternary mixture of the studied drugs by the spectrum of AM to get the division spectrum, from which concentration of AM can be obtained by measuring the amplitude values in the plateau region at 360 nm. Then the amplitude value of the plateau region was subtracted from the division spectrum and HZ concentration was obtained by measuring the difference in amplitude values at 278.5 and 306 nm (corresponding to zero difference of TL) while the total concentration of HZ and TL in the mixture was measured at their isoabsorptive point in the division spectrum at 278.5 nm (Aiso). TL concentration is then obtained by subtraction. Method B; double divisor ratio spectra derivative spectrophotometry (RS-DS) and method C; mean centering of ratio spectra (MCR) spectrophotometric methods. The proposed methods did not require any initial separation steps prior the analysis of the three drugs. A comparative study was done between the three methods regarding their; simplicity, sensitivity and limitations. Specificity was investigated by analyzing the synthetic mixtures containing different ratios of the three studied drugs and their tablets dosage form. Statistical comparison of the obtained results with those found by the official methods was done, differences were non-significant in regard to accuracy and precision. The three methods were validated in accordance with ICH guidelines and can be used for quality control laboratories for TL, HZ and AM.

  10. Experimental validation of the twins prediction program for rolling noise. Pt.2: results

    NARCIS (Netherlands)

    Thompson, D.J.; Fodiman, P.; Mahé, H.

    1996-01-01

    Two extensive measurement campaigns have been carried out to validate the TWINS prediction program for rolling noise, as described in part 1 of this paper. This second part presents the experimental results of vibration and noise during train pass-bys and compares them with predictions from the

  11. Validation of a method for assessing resident physicians' quality improvement proposals.

    Science.gov (United States)

    Leenstra, James L; Beckman, Thomas J; Reed, Darcy A; Mundell, William C; Thomas, Kris G; Krajicek, Bryan J; Cha, Stephen S; Kolars, Joseph C; McDonald, Furman S

    2007-09-01

    Residency programs involve trainees in quality improvement (QI) projects to evaluate competency in systems-based practice and practice-based learning and improvement. Valid approaches to assess QI proposals are lacking. We developed an instrument for assessing resident QI proposals--the Quality Improvement Proposal Assessment Tool (QIPAT-7)-and determined its validity and reliability. QIPAT-7 content was initially obtained from a national panel of QI experts. Through an iterative process, the instrument was refined, pilot-tested, and revised. Seven raters used the instrument to assess 45 resident QI proposals. Principal factor analysis was used to explore the dimensionality of instrument scores. Cronbach's alpha and intraclass correlations were calculated to determine internal consistency and interrater reliability, respectively. QIPAT-7 items comprised a single factor (eigenvalue = 3.4) suggesting a single assessment dimension. Interrater reliability for each item (range 0.79 to 0.93) and internal consistency reliability among the items (Cronbach's alpha = 0.87) were high. This method for assessing resident physician QI proposals is supported by content and internal structure validity evidence. QIPAT-7 is a useful tool for assessing resident QI proposals. Future research should determine the reliability of QIPAT-7 scores in other residency and fellowship training programs. Correlations should also be made between assessment scores and criteria for QI proposal success such as implementation of QI proposals, resident scholarly productivity, and improved patient outcomes.

  12. Validation of an ultra-fast UPLC-UV method for the separation of antituberculosis tablets.

    Science.gov (United States)

    Nguyen, Dao T-T; Guillarme, Davy; Rudaz, Serge; Veuthey, Jean-Luc

    2008-04-01

    A simple method using ultra performance LC (UPLC) coupled with UV detection was developed and validated for the determination of antituberculosis drugs in combined dosage form, i. e. isoniazid (ISN), pyrazinamide (PYR) and rifampicin (RIF). Drugs were separated on a short column (2.1 mm x 50 mm) packed with 1.7 mum particles, using an elution gradient procedure. At 30 degrees C, less than 2 min was necessary for the complete separation of the three antituberculosis drugs, while the original USP method was performed in 15 min. Further improvements were obtained with the combination of UPLC and high temperature (up to 90 degrees C), namely HT-UPLC, which allows the application of higher mobile phase flow rates. Therefore, the separation of ISN, PYR and RIF was performed in less than 1 min. After validation (selectivity, trueness, precision and accuracy), both methods (UPLC and HT-UPLC) have proven suitable for the routine quality control analysis of antituberculosis drugs in combined dosage form. Additionally, a large number of samples per day can be analysed due to the short analysis times.

  13. Proposal for Requirement Validation Criteria and Method Based on Actor Interaction

    Science.gov (United States)

    Hattori, Noboru; Yamamoto, Shuichiro; Ajisaka, Tsuneo; Kitani, Tsuyoshi

    We propose requirement validation criteria and a method based on the interaction between actors in an information system. We focus on the cyclical transitions of one actor's situation against another and clarify observable stimuli and responses based on these transitions. Both actors' situations can be listed in a state transition table, which describes the observable stimuli or responses they send or receive. Examination of the interaction between both actors in the state transition tables enables us to detect missing or defective observable stimuli or responses. Typically, this method can be applied to the examination of the interaction between a resource managed by the information system and its user. As a case study, we analyzed 332 requirement defect reports of an actual system development project in Japan. We found that there were a certain amount of defects regarding missing or defective stimuli and responses, which can be detected using our proposed method if this method is used in the requirement definition phase. This means that we can reach a more complete requirement definition with our proposed method.

  14. Validity of the Remote Food Photography Method against Doubly Labeled Water among Minority Preschoolers

    OpenAIRE

    Nicklas, Theresa; Saab, Rabab; Islam, Noemi G.; Wong, William; Butte, Nancy; Schulin, Rebecca; Liu, Yan; Apolzan, John W.; Myers, Candice A.; Martin, Corby K.

    2017-01-01

    Objective To determine the validity of energy intake (EI) estimations made using the Remote Food Photography Method (RFPM) compared to the doubly-labeled water (DLW) method in minority preschool children in a free-living environment. Methods Seven days of food intake and spot urine samples excluding first void collections for DLW analysis were obtained on 39 3-to-5 year old Hispanic and African American children. Using an iPhone, caregivers captured before and after pictures of the child’s in...

  15. Measurement and data analysis methods for field-scale wind erosion studies and model validation

    NARCIS (Netherlands)

    Zobeck, T.M.; Sterk, G.; Funk, R.F.; Rajot, J.L.; Stout, J.E.; Scott Van Pelt, R.

    2003-01-01

    Accurate and reliable methods of measuring windblown sediment are needed to confirm, validate, and improve erosion models, assess the intensity of aeolian processes and related damage, determine the source of pollutants, and for other applications. This paper outlines important principles to

  16. A method for modeling laterally asymmetric proton beamlets resulting from collimation

    Energy Technology Data Exchange (ETDEWEB)

    Gelover, Edgar; Wang, Dongxu; Flynn, Ryan T.; Hyer, Daniel E. [Department of Radiation Oncology, University of Iowa, 200 Hawkins Drive, Iowa City, Iowa 52242 (United States); Hill, Patrick M. [Department of Human Oncology, University of Wisconsin, 600 Highland Avenue, Madison, Wisconsin 53792 (United States); Gao, Mingcheng; Laub, Steve; Pankuch, Mark [Division of Medical Physics, CDH Proton Center, 4455 Weaver Parkway, Warrenville, Illinois 60555 (United States)

    2015-03-15

    Purpose: To introduce a method to model the 3D dose distribution of laterally asymmetric proton beamlets resulting from collimation. The model enables rapid beamlet calculation for spot scanning (SS) delivery using a novel penumbra-reducing dynamic collimation system (DCS) with two pairs of trimmers oriented perpendicular to each other. Methods: Trimmed beamlet dose distributions in water were simulated with MCNPX and the collimating effects noted in the simulations were validated by experimental measurement. The simulated beamlets were modeled analytically using integral depth dose curves along with an asymmetric Gaussian function to represent fluence in the beam’s eye view (BEV). The BEV parameters consisted of Gaussian standard deviations (sigmas) along each primary axis (σ{sub x1},σ{sub x2},σ{sub y1},σ{sub y2}) together with the spatial location of the maximum dose (μ{sub x},μ{sub y}). Percent depth dose variation with trimmer position was accounted for with a depth-dependent correction function. Beamlet growth with depth was accounted for by combining the in-air divergence with Hong’s fit of the Highland approximation along each axis in the BEV. Results: The beamlet model showed excellent agreement with the Monte Carlo simulation data used as a benchmark. The overall passing rate for a 3D gamma test with 3%/3 mm passing criteria was 96.1% between the analytical model and Monte Carlo data in an example treatment plan. Conclusions: The analytical model is capable of accurately representing individual asymmetric beamlets resulting from use of the DCS. This method enables integration of the DCS into a treatment planning system to perform dose computation in patient datasets. The method could be generalized for use with any SS collimation system in which blades, leaves, or trimmers are used to laterally sharpen beamlets.

  17. A method for modeling laterally asymmetric proton beamlets resulting from collimation

    International Nuclear Information System (INIS)

    Gelover, Edgar; Wang, Dongxu; Flynn, Ryan T.; Hyer, Daniel E.; Hill, Patrick M.; Gao, Mingcheng; Laub, Steve; Pankuch, Mark

    2015-01-01

    Purpose: To introduce a method to model the 3D dose distribution of laterally asymmetric proton beamlets resulting from collimation. The model enables rapid beamlet calculation for spot scanning (SS) delivery using a novel penumbra-reducing dynamic collimation system (DCS) with two pairs of trimmers oriented perpendicular to each other. Methods: Trimmed beamlet dose distributions in water were simulated with MCNPX and the collimating effects noted in the simulations were validated by experimental measurement. The simulated beamlets were modeled analytically using integral depth dose curves along with an asymmetric Gaussian function to represent fluence in the beam’s eye view (BEV). The BEV parameters consisted of Gaussian standard deviations (sigmas) along each primary axis (σ x1 ,σ x2 ,σ y1 ,σ y2 ) together with the spatial location of the maximum dose (μ x ,μ y ). Percent depth dose variation with trimmer position was accounted for with a depth-dependent correction function. Beamlet growth with depth was accounted for by combining the in-air divergence with Hong’s fit of the Highland approximation along each axis in the BEV. Results: The beamlet model showed excellent agreement with the Monte Carlo simulation data used as a benchmark. The overall passing rate for a 3D gamma test with 3%/3 mm passing criteria was 96.1% between the analytical model and Monte Carlo data in an example treatment plan. Conclusions: The analytical model is capable of accurately representing individual asymmetric beamlets resulting from use of the DCS. This method enables integration of the DCS into a treatment planning system to perform dose computation in patient datasets. The method could be generalized for use with any SS collimation system in which blades, leaves, or trimmers are used to laterally sharpen beamlets

  18. A method for modeling laterally asymmetric proton beamlets resulting from collimation

    Science.gov (United States)

    Gelover, Edgar; Wang, Dongxu; Hill, Patrick M.; Flynn, Ryan T.; Gao, Mingcheng; Laub, Steve; Pankuch, Mark; Hyer, Daniel E.

    2015-01-01

    Purpose: To introduce a method to model the 3D dose distribution of laterally asymmetric proton beamlets resulting from collimation. The model enables rapid beamlet calculation for spot scanning (SS) delivery using a novel penumbra-reducing dynamic collimation system (DCS) with two pairs of trimmers oriented perpendicular to each other. Methods: Trimmed beamlet dose distributions in water were simulated with MCNPX and the collimating effects noted in the simulations were validated by experimental measurement. The simulated beamlets were modeled analytically using integral depth dose curves along with an asymmetric Gaussian function to represent fluence in the beam’s eye view (BEV). The BEV parameters consisted of Gaussian standard deviations (sigmas) along each primary axis (σx1,σx2,σy1,σy2) together with the spatial location of the maximum dose (μx,μy). Percent depth dose variation with trimmer position was accounted for with a depth-dependent correction function. Beamlet growth with depth was accounted for by combining the in-air divergence with Hong’s fit of the Highland approximation along each axis in the BEV. Results: The beamlet model showed excellent agreement with the Monte Carlo simulation data used as a benchmark. The overall passing rate for a 3D gamma test with 3%/3 mm passing criteria was 96.1% between the analytical model and Monte Carlo data in an example treatment plan. Conclusions: The analytical model is capable of accurately representing individual asymmetric beamlets resulting from use of the DCS. This method enables integration of the DCS into a treatment planning system to perform dose computation in patient datasets. The method could be generalized for use with any SS collimation system in which blades, leaves, or trimmers are used to laterally sharpen beamlets. PMID:25735287

  19. A simple method for validation and verification of pipettes mounted on automated liquid handlers

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Hansen, Anders Johannes; Frøslev, Tobias G

    2011-01-01

    We have implemented a simple, inexpensive, and fast procedure for validation and verification of the performance of pipettes mounted on automated liquid handlers (ALHs) as necessary for laboratories accredited under ISO 17025. A six- or seven-step serial dilution of OrangeG was prepared in quadru......We have implemented a simple, inexpensive, and fast procedure for validation and verification of the performance of pipettes mounted on automated liquid handlers (ALHs) as necessary for laboratories accredited under ISO 17025. A six- or seven-step serial dilution of OrangeG was prepared...... are freely available. In conclusion, we have set up a simple, inexpensive, and fast solution for the continuous validation of ALHs used for accredited work according to the ISO 17025 standard. The method is easy to use for aqueous solutions but requires a spectrophotometer that can read microtiter plates....

  20. Quantification of imatinib in human serum: validation of a high-performance liquid chromatography-mass spectrometry method for therapeutic drug monitoring and pharmacokinetic assays

    Directory of Open Access Journals (Sweden)

    Rezende VM

    2013-08-01

    Full Text Available Vinicius Marcondes Rezende,1 Ariane Rivellis,1 Mafalda Megumi Yoshinaga Novaes,1 Dalton de Alencar Fisher Chamone,2 Israel Bendit1,21Laboratory of Tumor Biology, 2Department of Hematology, School of Medicine, University of São Paulo, São Paulo, BrazilBackground: Imatinib mesylate has been a breakthrough treatment for chronic myeloid leukemia. It has become the ideal tyrosine kinase inhibitor and the standard treatment for chronic-phase leukemia. Striking results have recently been reported, but intolerance to imatinib and noncompliance with treatment remain to be solved. Molecular monitoring by quantitative real-time polymerase chain reaction is the gold standard for monitoring patients, and imatinib blood levels have also become an important tool for monitoring.Methods: A fast and cheap method was developed and validated using high-performance liquid chromatography-mass spectrometry for quantification of imatinib in human serum and tamsulosin as the internal standard. Remarkable advantages of the method includes use of serum instead of plasma, less time spent on processing and analysis, simpler procedures, and requiring reduced amounts of biological material, solvents, and reagents. Stability of the analyte was also studied. This research also intended to drive the validation scheme in clinical centers. The method was validated according to the requirements of the US Food and Drug Administration and Brazilian National Health Surveillance Agency within the range of 0.500–10.0 µg/mL with a limit of detection of 0.155 µg/mL. Stability data for the analyte are also presented.Conclusion: Given that the validated method has proved to be linear, accurate, precise, and robust, it is suitable for pharmacokinetic assays, such as bioavailability and bioequivalence, and is being successfully applied in routine therapeutic drug monitoring in the hospital service.Keywords: imatinib, high-performance liquid chromatography-mass spectrometry, therapeutic

  1. A validated fast difference spectrophotometric method for 5-hydroxymethyl-2-furfural (HMF) determination in corn syrups.

    Science.gov (United States)

    de Andrade, Jucimara Kulek; de Andrade, Camila Kulek; Komatsu, Emy; Perreault, Hélène; Torres, Yohandra Reyes; da Rosa, Marcos Roberto; Felsner, Maria Lurdes

    2017-08-01

    Corn syrups, important ingredients used in food and beverage industries, often contain high levels of 5-hydroxymethyl-2-furfural (HMF), a toxic contaminant. In this work, an in house validation of a difference spectrophotometric method for HMF analysis in corn syrups was developed using sophisticated statistical tools by the first time. The methodology showed excellent analytical performance with good selectivity, linearity (R 2 =99.9%, r>0.99), accuracy and low limits (LOD=0.10mgL -1 and LOQ=0.34mgL -1 ). An excellent precision was confirmed by repeatability (RSD (%)=0.30) and intermediate precision (RSD (%)=0.36) estimates and by Horrat value (0.07). A detailed study of method precision using a nested design demonstrated that variation sources such as instruments, operators and time did not interfere in the variability of results within laboratory and consequently in its intermediate precision. The developed method is environmentally friendly, fast, cheap and easy to implement resulting in an attractive alternative for corn syrups quality control in industries and official laboratories. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Method validation using weighted linear regression models for quantification of UV filters in water samples.

    Science.gov (United States)

    da Silva, Claudia Pereira; Emídio, Elissandro Soares; de Marchi, Mary Rosa Rodrigues

    2015-01-01

    This paper describes the validation of a method consisting of solid-phase extraction followed by gas chromatography-tandem mass spectrometry for the analysis of the ultraviolet (UV) filters benzophenone-3, ethylhexyl salicylate, ethylhexyl methoxycinnamate and octocrylene. The method validation criteria included evaluation of selectivity, analytical curve, trueness, precision, limits of detection and limits of quantification. The non-weighted linear regression model has traditionally been used for calibration, but it is not necessarily the optimal model in all cases. Because the assumption of homoscedasticity was not met for the analytical data in this work, a weighted least squares linear regression was used for the calibration method. The evaluated analytical parameters were satisfactory for the analytes and showed recoveries at four fortification levels between 62% and 107%, with relative standard deviations less than 14%. The detection limits ranged from 7.6 to 24.1 ng L(-1). The proposed method was used to determine the amount of UV filters in water samples from water treatment plants in Araraquara and Jau in São Paulo, Brazil. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Online In-Core Thermal Neutron Flux Measurement for the Validation of Computational Methods

    International Nuclear Information System (INIS)

    Mohamad Hairie Rabir; Muhammad Rawi Mohamed Zin; Yahya Ismail

    2016-01-01

    In order to verify and validate the computational methods for neutron flux calculation in RTP calculations, a series of thermal neutron flux measurement has been performed. The Self Powered Neutron Detector (SPND) was used to measure thermal neutron flux to verify the calculated neutron flux distribution in the TRIGA reactor. Measurements results obtained online for different power level of the reactor. The experimental results were compared to the calculations performed with Monte Carlo code MCNP using detailed geometrical model of the reactor. The calculated and measured thermal neutron flux in the core are in very good agreement indicating that the material and geometrical properties of the reactor core are modelled well. In conclusion one can state that our computational model describes very well the neutron flux distribution in the reactor core. Since the computational model properly describes the reactor core it can be used for calculations of reactor core parameters and for optimization of RTP utilization. (author)

  4. Adaptation, validation and application of the chemo-thermal oxidation method to quantify black carbon in soils

    International Nuclear Information System (INIS)

    Agarwal, Tripti; Bucheli, Thomas D.

    2011-01-01

    The chemo-thermal oxidation method at 375 o C (CTO-375) has been widely used to quantify black carbon (BC) in sediments. In the present study, CTO-375 was tested and adapted for application to soil, accounting for some matrix specific properties like high organic carbon (≤39%) and carbonate (≤37%) content. Average recoveries of standard reference material SRM-2975 ranged from 25 to 86% for nine representative Swiss and Indian samples, which is similar to literature data for sediments. The adapted method was applied to selected samples of the Swiss soil monitoring network (NABO). BC content exhibited different patterns in three soil profiles while contribution of BC to TOC was found maximum below the topsoil at all three sites, however at different depths (60-130 cm). Six different NABO sites exhibited largely constant BC concentrations over the last 25 years, with short-term (6 months) prevailing over long-term (5 years) temporal fluctuations. - Research highlights: → The CTO-375 method was adapted and validated for BC analysis in soils. → Method validation figures of merit proofed satisfactory. → Application is shown with soil cores and topsoil temporal variability. → BC content can be elevated in subsurface soils. → BC contents in surface soils were largely constant over the last 25 years. - Although widely used also for soils, the chemo-thermal oxidation method at 375 o C to quantify black carbon has never been properly validated for this matrix before.

  5. Development and validation of an event-specific quantitative PCR method for genetically modified maize MIR162.

    Science.gov (United States)

    Takabatake, Reona; Masubuchi, Tomoko; Futo, Satoshi; Minegishi, Yasutaka; Noguchi, Akio; Kondo, Kazunari; Teshima, Reiko; Kurashima, Takeyo; Mano, Junichi; Kitta, Kazumi

    2014-01-01

    A novel real-time PCR-based analytical method was developed for the event-specific quantification of a genetically modified (GM) maize event, MIR162. We first prepared a standard plasmid for MIR162 quantification. The conversion factor (Cf) required to calculate the genetically modified organism (GMO) amount was empirically determined for two real-time PCR instruments, the Applied Biosystems 7900HT (ABI7900) and the Applied Biosystems 7500 (ABI7500) for which the determined Cf values were 0.697 and 0.635, respectively. To validate the developed method, a blind test was carried out in an interlaboratory study. The trueness and precision were evaluated as the bias and reproducibility of relative standard deviation (RSDr). The determined biases were less than 25% and the RSDr values were less than 20% at all evaluated concentrations. These results suggested that the limit of quantitation of the method was 0.5%, and that the developed method would thus be suitable for practical analyses for the detection and quantification of MIR162.

  6. Assessment of juveniles testimonies’ validity

    Directory of Open Access Journals (Sweden)

    Dozortseva E.G.

    2015-12-01

    Full Text Available The article presents a review of the English language publications concerning the history and the current state of differential psychological assessment of validity of testimonies produced by child and adolescent victims of crimes. The topicality of the problem in Russia is high due to the tendency of Russian specialists to use methodical means and instruments developed abroad in this sphere for forensic assessments of witness testimony veracity. A system of Statement Validity Analysis (SVA by means of Criteria-Based Content Analysis (CBCA and Validity Checklist is described. The results of laboratory and field studies of validity of CBCA criteria on the basis of child and adult witnesses are discussed. The data display a good differentiating capacity of the method, however, a high level of error probability. The researchers recommend implementation of SVA in the criminal investigation process, but not in the forensic assessment. New perspective developments in the field of methods for differentiation of witness statements based on the real experience and fictional are noted. The conclusion is drawn that empirical studies and a special work for adaptation and development of new approaches should precede their implementation into Russian criminal investigation and forensic assessment practice

  7. Development and validation of dissolution method for carvedilol compression-coated tablets

    Directory of Open Access Journals (Sweden)

    Ritesh Shah

    2011-12-01

    Full Text Available The present study describes the development and validation of a dissolution method for carvedilol compression-coated tablets. Dissolution test was performed using a TDT-06T dissolution apparatus. Based on the physiological conditions of the body, 0.1N hydrochloric acid was used as dissolution medium and release was monitored for 2 hours to verify the immediate release pattern of the drug in acidic pH, followed by pH 6.8 in citric-phosphate buffer for 22 hours, to simulate a sustained release pattern in the intestine. Influences of rotation speed and surfactant concentration in medium were evaluated. Samples were analysed by validated UV visible spectrophotometric method at 286 nm. 1% sodium lauryl sulphate (SLS was found to be optimum for improving carvedilol solubility in pH 6.8 citric-phosphate buffer. Analysis of variance showed no significant difference between the results obtained at 50 and 100 rpm. The discriminating dissolution method was successfully developed for carvedilol compression-coated tablets. The conditions that allowed dissolution determination were USP type I apparatus at 100 rpm, containing 1000 ml of 0.1N HCl for 2 hours, followed by pH 6.8 citric-phosphate buffer with 1% SLS for 22 hours at 37.0 ± 0.5 ºC. Samples were analysed by UV spectrophotometric method and validated as per ICH guidelines.O presente estudo descreve o desenvolvimento e a validação de método de dissolução para comprimidos revestidos de carvedilol. O teste de dissolução foi efetuado utilizando-se o aparelho para dissolução TDT-06T. Com base nas condições fisiológicas do organismo, utilizou-se ácido clorídrico 0,1 N como meio de dissolução e a liberação foi monitorada por 2 horas para se verificar o padrão de liberação imediata do fármaco em condições de pH baixo, seguidas por pH 6,8 em tampão cítrico-fosfato por 22 horas, para simular o padrão de liberação controlada no intestino. Avaliou-se a influência da velocidade de

  8. Validity of verbal autopsy method to determine causes of death among adults in the urban setting of Ethiopia

    Directory of Open Access Journals (Sweden)

    Misganaw Awoke

    2012-08-01

    Full Text Available Abstract Background Verbal autopsy has been widely used to estimate causes of death in settings with inadequate vital registries, but little is known about its validity. This analysis was part of Addis Ababa Mortality Surveillance Program to examine the validity of verbal autopsy for determining causes of death compared with hospital medical records among adults in the urban setting of Ethiopia. Methods This validation study consisted of comparison of verbal autopsy final diagnosis with hospital diagnosis taken as a “gold standard”. In public and private hospitals of Addis Ababa, 20,152 adult deaths (15 years and above were recorded between 2007 and 2010. With the same period, a verbal autopsy was conducted for 4,776 adult deaths of which, 1,356 were deceased in any of Addis Ababa hospitals. Then, verbal autopsy and hospital data sets were merged using the variables; full name of the deceased, sex, address, age, place and date of death. We calculated sensitivity, specificity and positive predictive values with 95% confidence interval. Results After merging, a total of 335 adult deaths were captured. For communicable diseases, the values of sensitivity, specificity and positive predictive values of verbal autopsy diagnosis were 79%, 78% and 68% respectively. For non-communicable diseases, sensitivity of the verbal autopsy diagnoses was 69%, specificity 78% and positive predictive value 79%. Regarding injury, sensitivity of the verbal autopsy diagnoses was 70%, specificity 98% and positive predictive value 83%. Higher sensitivity was achieved for HIV/AIDS and tuberculosis, but lower specificity with relatively more false positives. Conclusion These findings may indicate the potential of verbal autopsy to provide cost-effective information to guide policy on communicable and non communicable diseases double burden among adults in Ethiopia. Thus, a well structured verbal autopsy method, followed by qualified physician reviews could be capable of

  9. Validity of verbal autopsy method to determine causes of death among adults in the urban setting of Ethiopia

    Science.gov (United States)

    2012-01-01

    Background Verbal autopsy has been widely used to estimate causes of death in settings with inadequate vital registries, but little is known about its validity. This analysis was part of Addis Ababa Mortality Surveillance Program to examine the validity of verbal autopsy for determining causes of death compared with hospital medical records among adults in the urban setting of Ethiopia. Methods This validation study consisted of comparison of verbal autopsy final diagnosis with hospital diagnosis taken as a “gold standard”. In public and private hospitals of Addis Ababa, 20,152 adult deaths (15 years and above) were recorded between 2007 and 2010. With the same period, a verbal autopsy was conducted for 4,776 adult deaths of which, 1,356 were deceased in any of Addis Ababa hospitals. Then, verbal autopsy and hospital data sets were merged using the variables; full name of the deceased, sex, address, age, place and date of death. We calculated sensitivity, specificity and positive predictive values with 95% confidence interval. Results After merging, a total of 335 adult deaths were captured. For communicable diseases, the values of sensitivity, specificity and positive predictive values of verbal autopsy diagnosis were 79%, 78% and 68% respectively. For non-communicable diseases, sensitivity of the verbal autopsy diagnoses was 69%, specificity 78% and positive predictive value 79%. Regarding injury, sensitivity of the verbal autopsy diagnoses was 70%, specificity 98% and positive predictive value 83%. Higher sensitivity was achieved for HIV/AIDS and tuberculosis, but lower specificity with relatively more false positives. Conclusion These findings may indicate the potential of verbal autopsy to provide cost-effective information to guide policy on communicable and non communicable diseases double burden among adults in Ethiopia. Thus, a well structured verbal autopsy method, followed by qualified physician reviews could be capable of providing reasonable cause

  10. Development and validation of a stability-indicating RP–HPLC method for estimation of atazanavir sulfate in bulk

    Directory of Open Access Journals (Sweden)

    S. Dey

    2017-04-01

    Full Text Available A stability-indicating reverse phase–high performance liquid chromatography (RP–HPLC method was developed and validated for the determination of atazanavir sulfate in tablet dosage forms using C18 column Phenomenix (250 mm×4.6 mm, 5 μm with a mobile phase consisting of 900 mL of HPLC grade methanol and 100 mL of water of HPLC grade. The pH was adjusted to 3.55 with acetic acid. The mobile phase was sonicated for 10 min and filtered through a 0.45 μm membrane filter at a flow rate of 0.5 mL/min. The detection was carried out at 249 nm and retention time of atazanavir sulfate was found to be 8.323 min. Linearity was observed from 10 to 90 μg/mL (coefficient of determination R2 was 0.999 with equation, y=23.427x+37.732. Atazanavir sulfate was subjected to stress conditions including acidic, alkaline, oxidation, photolysis and thermal degradation, and the results showed that it was more sensitive towards acidic degradation. The method was validated as per ICH guidelines.

  11. Validation of Plutonium Radioisotopes Analysis Using Alpha Spectrometry

    International Nuclear Information System (INIS)

    Noor Fadzilah Yusof; Jalal Sharib; Mohd Tarmizi Ishak; Zulkifli Daud; Abdul Kadir Ishak

    2016-01-01

    This paper presents the validation of an established method used to detect plutonium (Pu) radioisotopes in marine environment samples. The separation method consists of sample digestion, anion exchange, purification, electroplating and counting by an alpha spectrometry. Applying the method on standard reference materials from marine environment, the results are validated using seven parameters, namely specificity, linearity, bias or accuracy, detection limit, precision/ repeatability, reproducibility/ ruggedness and robustness in accordance with International Organization for Standardization (ISO) guidelines. The findings were that the results obtained were in a good agreement and satisfactory compared to the provided readings from certificate of reference materials. (author)

  12. Statistical Validation of Normal Tissue Complication Probability Models

    Energy Technology Data Exchange (ETDEWEB)

    Xu Chengjian, E-mail: c.j.xu@umcg.nl [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Schaaf, Arjen van der; Veld, Aart A. van' t; Langendijk, Johannes A. [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Schilstra, Cornelis [Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen (Netherlands); Radiotherapy Institute Friesland, Leeuwarden (Netherlands)

    2012-09-01

    Purpose: To investigate the applicability and value of double cross-validation and permutation tests as established statistical approaches in the validation of normal tissue complication probability (NTCP) models. Methods and Materials: A penalized regression method, LASSO (least absolute shrinkage and selection operator), was used to build NTCP models for xerostomia after radiation therapy treatment of head-and-neck cancer. Model assessment was based on the likelihood function and the area under the receiver operating characteristic curve. Results: Repeated double cross-validation showed the uncertainty and instability of the NTCP models and indicated that the statistical significance of model performance can be obtained by permutation testing. Conclusion: Repeated double cross-validation and permutation tests are recommended to validate NTCP models before clinical use.

  13. Quantification of imatinib in human serum: validation of a high-performance liquid chromatography-mass spectrometry method for therapeutic drug monitoring and pharmacokinetic assays.

    Science.gov (United States)

    Rezende, Vinicius Marcondes; Rivellis, Ariane; Novaes, Mafalda Megumi Yoshinaga; de Alencar Fisher Chamone, Dalton; Bendit, Israel

    2013-01-01

    Imatinib mesylate has been a breakthrough treatment for chronic myeloid leukemia. It has become the ideal tyrosine kinase inhibitor and the standard treatment for chronic-phase leukemia. Striking results have recently been reported, but intolerance to imatinib and noncompliance with treatment remain to be solved. Molecular monitoring by quantitative real-time polymerase chain reaction is the gold standard for monitoring patients, and imatinib blood levels have also become an important tool for monitoring. A fast and cheap method was developed and validated using high-performance liquid chromatography-mass spectrometry for quantification of imatinib in human serum and tamsulosin as the internal standard. Remarkable advantages of the method includes use of serum instead of plasma, less time spent on processing and analysis, simpler procedures, and requiring reduced amounts of biological material, solvents, and reagents. Stability of the analyte was also studied. This research also intended to drive the validation scheme in clinical centers. The method was validated according to the requirements of the US Food and Drug Administration and Brazilian National Health Surveillance Agency within the range of 0.500-10.0 μg/mL with a limit of detection of 0.155 μg/mL. Stability data for the analyte are also presented. Given that the validated method has proved to be linear, accurate, precise, and robust, it is suitable for pharmacokinetic assays, such as bioavailability and bioequivalence, and is being successfully applied in routine therapeutic drug monitoring in the hospital service.

  14. Validity of the Modified Baecke Questionnaire: comparison with energy expenditure according to the doubly labeled water method

    Directory of Open Access Journals (Sweden)

    Peeters Petra HM

    2008-05-01

    Full Text Available Abstract Background In epidemiological research, physical activity is usually assessed by questionnaires. Questionnaires are suitable for large study populations since they are relatively inexpensive and not very time consuming. However, questionnaire information is by definition subjective and prone to recall bias, especially among elderly subjects. The Modified Baecke Questionnaire, developed by Voorrips and coworkers, measures habitual physical activity in the elderly. The questionnaire includes questions on household activities, sports, and leisure time activities, over a time period of one year. The Modified Baecke Questionnaire results in a score to classify people as high, moderate, or low in daily physical activity, based on tertiles. Methods The validity of the Modified Baecke Questionnaire score was assessed among 21 elderly men and women using the doubly labeled water method as the reference criterion. This method is considered to be the gold standard for measuring energy expenditure in free-living individuals. Energy expenditure on physical activity is estimated by the ratio of total energy expenditure measured by the doubly labeled water method and resting metabolic rate measured by indirect calorimetry. This ratio is called the physical activity ratio. Results The Spearman correlation coefficient between the questionnaire score and the physical activity ratio (PAR was 0.54 (95% CI 0.22–0.66. Correct classification by the questionnaire occurred in 71% of participants who were in the lowest tertile of PAR, in 14% of participants in the middle tertile, and in 43% of participants in the highest tertile. Subjects were not wrongly classified in an opposite tertile. Conclusion The validity of the Modified Baecke Questionnaire is fair-to-moderate. This study shows that the questionnaire can correctly classify individuals as low or high active, but does a poor job for moderately active individuals.

  15. Validity of a Simple Method for Measuring Force-Velocity-Power Profile in Countermovement Jump.

    Science.gov (United States)

    Jiménez-Reyes, Pedro; Samozino, Pierre; Pareja-Blanco, Fernando; Conceição, Filipe; Cuadrado-Peñafiel, Víctor; González-Badillo, Juan José; Morin, Jean-Benoît

    2017-01-01

    To analyze the reliability and validity of a simple computation method to evaluate force (F), velocity (v), and power (P) output during a countermovement jump (CMJ) suitable for use in field conditions and to verify the validity of this computation method to compute the CMJ force-velocity (F-v) profile (including unloaded and loaded jumps) in trained athletes. Sixteen high-level male sprinters and jumpers performed maximal CMJs under 6 different load conditions (0-87 kg). A force plate sampling at 1000 Hz was used to record vertical ground-reaction force and derive vertical-displacement data during CMJ trials. For each condition, mean F, v, and P of the push-off phase were determined from both force-plate data (reference method) and simple computation measures based on body mass, jump height (from flight time), and push-off distance and used to establish the linear F-v relationship for each individual. Mean absolute bias values were 0.9% (± 1.6%), 4.7% (± 6.2%), 3.7% (± 4.8%), and 5% (± 6.8%) for F, v, P, and slope of the F-v relationship (S Fv ), respectively. Both methods showed high correlations for F-v-profile-related variables (r = .985-.991). Finally, all variables computed from the simple method showed high reliability, with ICC >.980 and CV push-off distance, and jump height are known.

  16. Development and Validation of HPLC Method for Determination of Crocetin, a constituent of Saffron, in Human Serum Samples

    Directory of Open Access Journals (Sweden)

    Amir Hooshang Mohammadpour

    2013-01-01

    Full Text Available Objective(s:The present study reports the development and validation of a sensitive and rapid extraction method beside high performance liquid chromatographic method for the determination of crocetin in human serum. Materials and Methods:The HPLC method was carried out by using a C18 reversed-phase column and a mobile phase composed of methanol/water/acetic acid (85:14.5:0.5 v/v/v at the flow rate of 0.8 ml/min. The UV detector was set at 423 nm and 13-cis retinoic acid was used as the internal standard. Serum samples were pretreated with solid-phase extraction using Bond Elut C18 (200mg cartridges or with direct precipitation using acetonitrile. Results:The calibration curves were linear over the range of 0.05-1.25 µg/ml for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction. The mean recoveries of crocetin over a concentration range of 0.05-5 µg/ml serum for direct precipitation method and 0.5-5 µg/ml for solid-phase extraction were above 70 % and 60 %, respectively. The intraday coefficients of variation were 0.37- 2.6% for direct precipitation method and 0.64 - 5.43% for solid-phase extraction. The inter day coefficients of variation were 1.69 – 6.03% for direct precipitation method and 5.13-12.74% for solid-phase extraction, respectively. The lower limit of quantification for crocetin was 0.05 µg/ml for direct precipitation method and 0.5 µg/ml for solid-phase extraction. Conclusion: The validated direct precipitation method for HPLC satisfied all of the criteria that were necessary for a bioanalytical method and could reliably quantitate crocetin in human serum for future clinical pharmacokinetic study

  17. Development and validation of Ketorolac Tromethamine in eye drop formulation by RP-HPLC method

    Directory of Open Access Journals (Sweden)

    G. Sunil

    2017-02-01

    Full Text Available A simple, precise and accurate method was developed and validated for analysis of Ketorolac Tromethamine in eye drop formulation. An isocratic HPLC analysis was performed on Kromosil C18 column (150 cm × 4.6 mm × 5 μm. The compound was separated with the mixture of methanol and ammonium dihydrogen phosphate buffer in the ratio of 55:45 V/V, pH 3.0 was adjusted with O-phosphoric acid as the mobile phase at flow of 1.5 mL min−1. UV detection was performed at 314 nm using photo diode array detection. The retention time was found to be 6.01 min. The system suitability parameters such as theoretical plate count, tailing and percentage RSD between six standard injections were within the limit. The method was validated according to ICH guidelines. Calibrations were linear over the concentration range of 50–150 μg mL−1 as indicated by correlation coefficient (r of 0.999. The robustness of the method was evaluated by deliberately altering the chromatographic conditions. The developed method can be applicable for routine quantitative analysis.

  18. Validation of micro-CT against the section method regarding the assessment of marginal leakage of sealants.

    NARCIS (Netherlands)

    Chen, X.; Cuijpers, V.M.J.I.; Fan, M.W.; Frencken, J.E.F.M.

    2012-01-01

    BACKGROUND: The aim of this study was to validate the micro-CT and related software against the section method using the stereomicroscope for marginal leakage assessment along the sealant-enamel interface. METHODS: Pits and fissures of the occlusal surface of 10 teeth were sealed with a

  19. Cleaning verification: A five parameter study of a Total Organic Carbon method development and validation for the cleaning assessment of residual detergents in manufacturing equipment.

    Science.gov (United States)

    Li, Xue; Ahmad, Imad A Haidar; Tam, James; Wang, Yan; Dao, Gina; Blasko, Andrei

    2018-02-05

    A Total Organic Carbon (TOC) based analytical method to quantitate trace residues of clean-in-place (CIP) detergents CIP100 ® and CIP200 ® on the surfaces of pharmaceutical manufacturing equipment was developed and validated. Five factors affecting the development and validation of the method were identified: diluent composition, diluent volume, extraction method, location for TOC sample preparation, and oxidant flow rate. Key experimental parameters were optimized to minimize contamination and to improve the sensitivity, recovery, and reliability of the method. The optimized concentration of the phosphoric acid in the swabbing solution was 0.05M, and the optimal volume of the sample solution was 30mL. The swab extraction method was 1min sonication. The use of a clean room, as compared to an isolated lab environment, was not required for method validation. The method was demonstrated to be linear with a correlation coefficient (R) of 0.9999. The average recoveries from stainless steel surfaces at multiple spike levels were >90%. The repeatability and intermediate precision results were ≤5% across the 2.2-6.6ppm range (50-150% of the target maximum carry over, MACO, limit). The method was also shown to be sensitive with a detection limit (DL) of 38ppb and a quantitation limit (QL) of 114ppb. The method validation demonstrated that the developed method is suitable for its intended use. The methodology developed in this study is generally applicable to the cleaning verification of any organic detergents used for the cleaning of pharmaceutical manufacturing equipment made of electropolished stainless steel material. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Assessment of Advanced Life Support competence when combining different test methods--reliability and validity

    DEFF Research Database (Denmark)

    Ringsted, C; Lippert, F; Hesselfeldt, R

    2007-01-01

    Cardiac Arrest Simulation Test (CASTest) scenarios for the assessments according to guidelines 2005. AIMS: To analyse the reliability and validity of the individual sub-tests provided by ERC and to find a combination of MCQ and CASTest that provides a reliable and valid single effect measure of ALS...... that possessed high reliability, equality of test sets, and ability to discriminate between the two groups of supposedly different ALS competence. CONCLUSIONS: ERC sub-tests of ALS competence possess sufficient reliability and validity. A combined ALS score with equal weighting of one MCQ and one CASTest can...... competence. METHODS: Two groups of participants were included in this randomised, controlled experimental study: a group of newly graduated doctors, who had not taken the ALS course (N=17) and a group of students, who had passed the ALS course 9 months before the study (N=16). Reliability in terms of inter...

  1. A simple HPLC method for the determination of halcinonide in lipid nanoparticles: development, validation, encapsulation efficiency, and in vitro drug permeation

    Directory of Open Access Journals (Sweden)

    Clarissa Elize Lopes

    2017-06-01

    Full Text Available ABSTRACT Halcinonide is a high-potency topical glucocorticoid used for skin inflammation treatments that presents toxic systemic effects. A simple and quick analytical method to quantify the amount of halcinonide encapsulated into lipid nanoparticles, such as polymeric lipid-core nanoparticles and solid lipid nanoparticles, was developed and validated regarding the drug's encapsulation efficiency and in vitro permeation. The development and validation of the analytical method were carried out using the high performance liquid chromatography with the UV detection at 239 nm. The validation parameters were specificity, linearity, precision and accuracy, limits of detection and quantitation, and robustness. The method presented an isocratic flow rate of 1.0 mL.min-1, a mobile phase methanol:water (85:15 v/v, and a retention time of 4.21 min. The method was validated according to international and national regulations. The halcinonide encapsulation efficiency in nanoparticles was greater than 99% and the in vitro drug permeation study showed that less than 9% of the drug permeated through the membrane, indicating a nanoparticle reservoir effect, which can reduce the halcinonide's toxic systemic effects. These studies demonstrated the applicability of the developed and validated analytical method to quantify halcinonide in lipid nanoparticles.

  2. Validation of the Five-Phase Method for Simulating Complex Fenestration Systems with Radiance against Field Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Geisler-Moroder, David [Bartenbach GmbH, Aldrans (Austria); Lee, Eleanor S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ward, Gregory J. [Anyhere Software, Albany, NY (United States)

    2016-08-29

    The Five-Phase Method (5-pm) for simulating complex fenestration systems with Radiance is validated against field measurements. The capability of the method to predict workplane illuminances, vertical sensor illuminances, and glare indices derived from captured and rendered high dynamic range (HDR) images is investigated. To be able to accurately represent the direct sun part of the daylight not only in sensor point simulations, but also in renderings of interior scenes, the 5-pm calculation procedure was extended. The validation shows that the 5-pm is superior to the Three-Phase Method for predicting horizontal and vertical illuminance sensor values as well as glare indices derived from rendered images. Even with input data from global and diffuse horizontal irradiance measurements only, daylight glare probability (DGP) values can be predicted within 10% error of measured values for most situations.

  3. Multianalytical Method Validation for Qualitative and Quantitative Analysis of Solvents of Abuse in Oral Fluid by HS-GC/MS

    Directory of Open Access Journals (Sweden)

    Bruna Claudia Coppe

    2016-01-01

    Full Text Available The use of oral fluid as a biological matrix to monitor the use of drugs of abuse is a global trend because it presents several advantages and good correlation to the blood level. Thus, the present work aimed to develop and validate an analytical method for quantification and detection of solvents used as inhalants of abuse in oral fluid (OF, using Quantisal™ as collector device by headspace and gas chromatography coupled with a mass detector (HS-GC/MS. Chromatographic separation was performed with a ZB-BAC1 column and the total time of analysis was 11.8 min. The method showed good linearity (correlation coefficient higher than 0.99 for all solvents. The limits of detection ranged from 0.05 to 5 mg/L, while the lower limits of quantification ranged from 2.5 to 12.5 mg/L. Accuracy, precision, matrix effect, and residual effect presented satisfactory results, meeting the criteria accepted for the validation of bioanalytical methods. The method showed good selectivity considering that, for solvents coeluting at the same retention time, resolution was performed by the mass detector. The method developed proved to be adequate when applied in OF samples from users of drugs and may be used to monitor the abuse of inhalants in routine forensic analyses.

  4. Validation of an improved abnormality insertion method for medical image perception investigations

    Science.gov (United States)

    Madsen, Mark T.; Durst, Gregory R.; Caldwell, Robert T.; Schartz, Kevin M.; Thompson, Brad H.; Berbaum, Kevin S.

    2009-02-01

    The ability to insert abnormalities in clinical tomographic images makes image perception studies with medical images practical. We describe a new insertion technique and its experimental validation that uses complementary image masks to select an abnormality from a library and place it at a desired location. The method was validated using a 4-alternative forced-choice experiment. For each case, four quadrants were simultaneously displayed consisting of 5 consecutive frames of a chest CT with a pulmonary nodule. One quadrant was unaltered, while the other 3 had the nodule from the unaltered quadrant artificially inserted. 26 different sets were generated and repeated with order scrambling for a total of 52 cases. The cases were viewed by radiology staff and residents who ranked each quadrant by realistic appearance. On average, the observers were able to correctly identify the unaltered quadrant in 42% of cases, and identify the unaltered quadrant both times it appeared in 25% of cases. Consensus, defined by a majority of readers, correctly identified the unaltered quadrant in only 29% of 52 cases. For repeats, the consensus observer successfully identified the unaltered quadrant only once. We conclude that the insertion method can be used to reliably place abnormalities in perception experiments.

  5. Validation of Modifications to the ANSR for Listeria Method for Improved Internal Positive Control Performance.

    Science.gov (United States)

    Alles, Susan; Meister, Evan; Hosking, Edan; Tovar, Eric; Shaulis, Rebecca; Schonfeld, Mark; Zhang, Lei; Li, Lin; Biswas, Preetha; Mozola, Mark; Donofrio, Robert; Chen, Yi

    2018-03-01

    A study was conducted to validate a minor reagent formulation change to the ANSR for Listeria method, Performance Tested MethodSM 101202. This change involves increasing the master mix volume prelyophilization by 40% and addition of salmon sperm DNA (nontarget DNA) to the master mix. These changes improve the robustness of the internal positive control response and reduce the possibility of obtaining invalid results due to weak-positive control curves. When three foods (hot dogs, Mexican-style cheese, and cantaloupe) and sponge samples taken from a stainless steel surface were tested, no significant differences in performance between the ANSR and U.S. Food and Drug Administration Bacteriological Analytical Manual or U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference culture procedures were observed for any of the matrixes as determined by probability of detection analysis. Inclusivity and exclusivity testing yielded 100% expected results for target and nontarget bacteria. Accelerated stability testing was carried out over a 7 week period and showed no decrease in assay performance over time.

  6. Reliability and Validity of the Footprint Assessment Method Using Photoshop CS5 Software in Young People with Down Syndrome.

    Science.gov (United States)

    Gutiérrez-Vilahú, Lourdes; Massó-Ortigosa, Núria; Rey-Abella, Ferran; Costa-Tutusaus, Lluís; Guerra-Balic, Myriam

    2016-05-01

    People with Down syndrome present skeletal abnormalities in their feet that can be analyzed by commonly used gold standard indices (the Hernández-Corvo index, the Chippaux-Smirak index, the Staheli arch index, and the Clarke angle) based on footprint measurements. The use of Photoshop CS5 software (Adobe Systems Software Ireland Ltd, Dublin, Ireland) to measure footprints has been validated in the general population. The present study aimed to assess the reliability and validity of this footprint assessment technique in the population with Down syndrome. Using optical podography and photography, 44 footprints from 22 patients with Down syndrome (11 men [mean ± SD age, 23.82 ± 3.12 years] and 11 women [mean ± SD age, 24.82 ± 6.81 years]) were recorded in a static bipedal standing position. A blinded observer performed the measurements using a validated manual method three times during the 4-month study, with 2 months between measurements. Test-retest was used to check the reliability of the Photoshop CS5 software measurements. Validity and reliability were obtained by intraclass correlation coefficient (ICC). The reliability test for all of the indices showed very good values for the Photoshop CS5 method (ICC, 0.982-0.995). Validity testing also found no differences between the techniques (ICC, 0.988-0.999). The Photoshop CS5 software method is reliable and valid for the study of footprints in young people with Down syndrome.

  7. Development and validation of an automated, microscopy-based method for enumeration of groups of intestinal bacteria

    NARCIS (Netherlands)

    Jansen, GJ; Wildeboer-Veloo, ACM; Tonk, RHJ; Franks, AH; Welling, G

    An automated microscopy-based method using fluorescently labelled 16S rRNA-targeted oligonucleotide probes directed against the predominant groups of intestinal bacteria was developed and validated. The method makes use of the Leica 600HR. image analysis system, a Kodak MegaPlus camera model 1.4 and

  8. Optimization of instrumental neutron activation analysis method by means of 2{sup k} experimental design technique aiming the validation of analytical procedures

    Energy Technology Data Exchange (ETDEWEB)

    Petroni, Robson; Moreira, Edson G., E-mail: rpetroni@ipen.br, E-mail: emoreira@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    In this study optimization of procedures and standardization of Instrumental Neutron Activation Analysis (INAA) methods were carried out for the determination of the elements arsenic, chromium, cobalt, iron, rubidium, scandium, selenium and zinc in biological materials. The aim is to validate the analytical methods for future accreditation at the National Institute of Metrology, Quality and Technology (INMETRO). The 2{sup k} experimental design was applied for evaluation of the individual contribution of selected variables of the analytical procedure in the final mass fraction result. Samples of Mussel Tissue Certified Reference Material and multi-element standards were analyzed considering the following variables: sample decay time, counting time and sample distance to detector. The standard multi-element concentration (comparator standard), mass of the sample and irradiation time were maintained constant in this procedure. By means of the statistical analysis and theoretical and experimental considerations it was determined the optimized experimental conditions for the analytical methods that will be adopted for the validation procedure of INAA methods in the Neutron Activation Analysis Laboratory (LAN) of the Research Reactor Center (CRPq) at the Nuclear and Energy Research Institute (IPEN - CNEN/SP). Optimized conditions were estimated based on the results of z-score tests, main effect and interaction effects. The results obtained with the different experimental configurations were evaluated for accuracy (precision and trueness) for each measurement. (author)

  9. Validation and implementation of liquid chromatographic-mass spectrometric (LC-MS) methods for the quantification of tenofovir prodrugs.

    Science.gov (United States)

    Hummert, Pamela; Parsons, Teresa L; Ensign, Laura M; Hoang, Thuy; Marzinke, Mark A

    2018-04-15

    The nucleotide reverse transcriptase inhibitor tenofovir (TFV) is widely administered in a disoproxil prodrug form (tenofovir disoproxil fumarate, TDF) for HIV management and prevention. Recently, novel prodrugs tenofovir alafenamide fumarate (TAF) and hexadecyloxypropyl tenofovir (CMX157) have been pursued for HIV treatment while minimizing adverse effects associated with systemic TFV exposure. Dynamic and sensitive bioanalytical tools are required to characterize the pharmacokinetics of these prodrugs in systemic circulation. Two parallel methods have been developed, one to combinatorially quantify TAF and TFV, and a second method for CMX157 quantification, in plasma. K 2 EDTA plasma was spiked with TAF and TFV, or CMX157. Following the addition of isotopically labeled internal standards and sample extraction via solid phase extraction (TAF and TFV) or protein precipitation (CMX157), samples were subjected to liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. For TAF and TFV, separation occurred using a Zorbax Eclipse Plus C18 Narrow Bore RR, 2.1 × 50 mm, 3.5 μm column and analytes were detected on an API5000 mass analyzer; CMX157 was separated using a Kinetex C8, 2.1 × 50 mm, 2.6 μm column and quantified using an API4500 mass spectrometer. Methods were validated according to FDA Bioanalytical Method Validation guidelines. Analytical methods: were optimized for the multiplexed monitoring of TAF and TFV, and CMX157 in plasma. The lower limits of quantification (LLOQs) for TAF, TFV, and CMX157 were 0.03, 1.0, and 0.25 ng/mL, respectively. Calibration curves were generated via weighted linear regression of standards. Intra- and inter-assay precision and accuracy studies demonstrated %CVs ≤ 14.4% and %DEVs ≤ ± 7.95%, respectively. Stability and matrix effects studies were also performed. All results were acceptable and in accordance with the recommended guidelines for bioanalytical methods. Assays were also

  10. PALEOEARTHQUAKES IN THE PRIBAIKALIE: METHODS AND RESULTS OF DATING

    Directory of Open Access Journals (Sweden)

    Oleg P. Smekalin

    2010-01-01

    Full Text Available In the Pribaikalie and adjacent territories, seismogeological studies have been underway for almost a half of the century and resulted in discovery of more than 70 dislocations of seismic or presumably seismic origin. With commencement of paleoseismic studies, dating of paleo-earthquakes was focused on as an indicator useful for long-term prediction of strong earthquakes. V.P. Solonenko [Solonenko, 1977] distinguished five methods for dating paleoseismogenic deformations, i.e. geological, engineering geological, historico-archeological, dendrochronological and radiocarbon methods. However, ages of the majority of seismic deformations, which were subject to studies at the initial stage of development of seismogeology in Siberia, were defined by methods of relative or correlation age determination.Since the 1980s, studies of seismogenic deformation in the Pribaikalie have been widely conducted with trenching. Mass sampling, followed with radiocarbon analyses and definition of absolute ages of paleo-earthquakes, provided new data on seismic regimes of the territory and rates of and recent displacements along active faults, and enhanced validity of methods of relative dating, in particular morphometry. Capacities of the morphometry method has significantly increased with introduction of laser techniques in surveys and digital processing of 3D relief models.Comprehensive seismogeological studies conducted in the Pribaikalie revealed 43 paleo-events within 16 seismogenic structures. Absolute ages of 18 paleo-events were defined by the radiocarbon age determination method. Judging by their ages, a number of dislocations were related with historical earthquakes which occurred in the 18th and 19th centuries, yet any reliable data on epicenters of such events are not available. The absolute and relative dating methods allowed us to identify sections in some paleoseismogenic structures by differences in ages of activation and thus provided new data for

  11. Validation of a cartridge method for the quality control determination of 99Tcm-HMPAO

    International Nuclear Information System (INIS)

    Pandos, G.; Penglis, S.; Tsopelas, C.; Royal Adelaide Hospital, Adelaide, SA

    1999-01-01

    Full text: The manufacturer's method for assessing the radiochemical purity (RCP) of ±-HMPAO requires the use of three solvent types on two different stationary phases, and is time-consuming (∼ 15 min) in consideration of the short shelf-life (30 min). An impetus to develop a rapid quality control procedure for this product has led to the use of a single strip Whatman 17 chromatography system using ethyl acetate as the developing solvent. This popular Whatman paper system was previously validates against the manufacturer's method. We have developed a new method to successfully determine the % RCP of ±-HMPAO, which employs a disposable, inexpensive and reusable Amprep C-18 cartridge with normal saline as a non-organic mobile phase. The Whatman paper system separates the primary lipophilic 99 Tc m -HMPAO complex from 99 Tc m O-2, 99 Tc m O 4 and secondary 99 Tc m -HMPAO complex at the origin. By comparison, the lipophilic portion was retained on the cartridge and the hydrophilic impurities were found in saline eluent with the cartridge method. Whatman 17 paper system results showed 95.1 ± I.7% 99 Tc m -HMPAO after 5 min and the cartridge method gave 95.5 ± 1.5% 99 Tc m -HMPAO (n = 8) after 3 min. The % 99 Tc m O 2 levels in 99 Tc m -HMPAO were insignificant. When a failed kit was assessed for RCP at 2.5 h post-reconstitution, the Whatman paper system and the cartridge method correlated well, resulting in 63.1 ± 2.7% and 62.9±2.1% 99 Tc m -HMPAO (n=3) respectively. Although the cartridge method may slightly overestimate the % RCP of 99 Tc m -HMPAO, it was found to be simple, rapid and reliable for the quality control analysis of routine 99 Tc m -HMPAO preparations

  12. Development and validation of ultra-performance liquid chromatographic method with tandem mass spectrometry for determination of lenalidomide in rabbit and human plasma

    Directory of Open Access Journals (Sweden)

    Iqbal Muzaffar

    2013-01-01

    Full Text Available Abstract Background Lenalidomide (LND is a potent novel thalidomide analog which demonstrated remarkable clinical activity in treatment of multiple myeloma disease via a multiple-pathways mechanism. Validated sensitive method with high throughput is required for the determination of lenalidomide for pharmacokinetics and toxicokinetic studies. Ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS is a preeminent analytical tool for rapid biomedical analysis. Results A simple, highly sensitive UPLC-MS/MS method was developed and validated for the determination of LND in rabbit and human plasma. After a simple protein precipitation using methanol, LND and carbamazepine (IS were separated on Acquity UPLC BEH™ C18 column (50 × 2.1 mm, i.d. 1.7 μm, Waters, USA using a mobile phase consisted of acetonitrile:water:formic acid (65:35:0.1%, v/v/v pumped at a flow rate of 0.2 mL/min. LND and IS were eluted at 0.71 and 1.92 min, respectively. The mass spectrometric determination was carried out using an electrospray interface operated in the positive mode with multiple reaction monitoring (MRM mode. The precursor to product ion transitions of m/z 260.1 > 149.0 and m/z 237.0 > 179.0 were used to quantify LND and IS, respectively. The method was linear in the concentration range of 0.23–1000 ng/mL with a limit of quantitation of 0.23 ng/mL. All the validation parameters were in the ranges acceptable by the guidelines of analytical method validation. Conclusion The proposed UPLC-MS/MS method is simple, rapid and highly sensitive, and hence it could be reliable for pharmacokinetic and toxicokinetic study in both animals and humans.

  13. Practical Bias Correction in Aerial Surveys of Large Mammals: Validation of Hybrid Double-Observer with Sightability Method against Known Abundance of Feral Horse (Equus caballus) Populations.

    Science.gov (United States)

    Lubow, Bruce C; Ransom, Jason I

    2016-01-01

    Reliably estimating wildlife abundance is fundamental to effective management. Aerial surveys are one of the only spatially robust tools for estimating large mammal populations, but statistical sampling methods are required to address detection biases that affect accuracy and precision of the estimates. Although various methods for correcting aerial survey bias are employed on large mammal species around the world, these have rarely been rigorously validated. Several populations of feral horses (Equus caballus) in the western United States have been intensively studied, resulting in identification of all unique individuals. This provided a rare opportunity to test aerial survey bias correction on populations of known abundance. We hypothesized that a hybrid method combining simultaneous double-observer and sightability bias correction techniques would accurately estimate abundance. We validated this integrated technique on populations of known size and also on a pair of surveys before and after a known number was removed. Our analysis identified several covariates across the surveys that explained and corrected biases in the estimates. All six tests on known populations produced estimates with deviations from the known value ranging from -8.5% to +13.7% and corrected by our statistical models. Our results validate the hybrid method, highlight its potentially broad applicability, identify some limitations, and provide insight and guidance for improving survey designs.

  14. Cross-validation and Peeling Strategies for Survival Bump Hunting using Recursive Peeling Methods

    Science.gov (United States)

    Dazard, Jean-Eudes; Choe, Michael; LeBlanc, Michael; Rao, J. Sunil

    2015-01-01

    We introduce a framework to build a survival/risk bump hunting model with a censored time-to-event response. Our Survival Bump Hunting (SBH) method is based on a recursive peeling procedure that uses a specific survival peeling criterion derived from non/semi-parametric statistics such as the hazards-ratio, the log-rank test or the Nelson--Aalen estimator. To optimize the tuning parameter of the model and validate it, we introduce an objective function based on survival or prediction-error statistics, such as the log-rank test and the concordance error rate. We also describe two alternative cross-validation techniques adapted to the joint task of decision-rule making by recursive peeling and survival estimation. Numerical analyses show the importance of replicated cross-validation and the differences between criteria and techniques in both low and high-dimensional settings. Although several non-parametric survival models exist, none addresses the problem of directly identifying local extrema. We show how SBH efficiently estimates extreme survival/risk subgroups unlike other models. This provides an insight into the behavior of commonly used models and suggests alternatives to be adopted in practice. Finally, our SBH framework was applied to a clinical dataset. In it, we identified subsets of patients characterized by clinical and demographic covariates with a distinct extreme survival outcome, for which tailored medical interventions could be made. An R package PRIMsrc (Patient Rule Induction Method in Survival, Regression and Classification settings) is available on CRAN (Comprehensive R Archive Network) and GitHub. PMID:27034730

  15. The face of pain--a pilot study to validate the measurement of facial pain expression with an improved electromyogram method.

    Science.gov (United States)

    Wolf, Karsten; Raedler, Thomas; Henke, Kai; Kiefer, Falk; Mass, Reinhard; Quante, Markus; Wiedemann, Klaus

    2005-01-01

    The purpose of this pilot study was to establish the validity of an improved facial electromyogram (EMG) method for the measurement of facial pain expression. Darwin defined pain in connection with fear as a simultaneous occurrence of eye staring, brow contraction and teeth chattering. Prkachin was the first to use the video-based Facial Action Coding System to measure facial expressions while using four different types of pain triggers, identifying a group of facial muscles around the eyes. The activity of nine facial muscles in 10 healthy male subjects was analyzed. Pain was induced through a laser system with a randomized sequence of different intensities. Muscle activity was measured with a new, highly sensitive and selective facial EMG. The results indicate two groups of muscles as key for pain expression. These results are in concordance with Darwin's definition. As in Prkachin's findings, one muscle group is assembled around the orbicularis oculi muscle, initiating eye staring. The second group consists of the mentalis and depressor anguli oris muscles, which trigger mouth movements. The results demonstrate the validity of the facial EMG method for measuring facial pain expression. Further studies with psychometric measurements, a larger sample size and a female test group should be conducted.

  16. Software validation applied to spreadsheets used in laboratories working under ISO/IEC 17025

    Science.gov (United States)

    Banegas, J. M.; Orué, M. W.

    2016-07-01

    Several documents deal with software validation. Nevertheless, more are too complex to be applied to validate spreadsheets - surely the most used software in laboratories working under ISO/IEC 17025. The method proposed in this work is intended to be directly applied to validate spreadsheets. It includes a systematic way to document requirements, operational aspects regarding to validation, and a simple method to keep records of validation results and modifications history. This method is actually being used in an accredited calibration laboratory, showing to be practical and efficient.

  17. Validation of the actuator line method using near wake measurements of the MEXICO rotor

    DEFF Research Database (Denmark)

    Nilsson, Karl; Shen, Wen Zhong; Sørensen, Jens Nørkær

    2015-01-01

    The purpose of the present work is to validate the capability of the actuator line method to compute vortex structures in the near wake behind the MEXICO experimental wind turbine rotor. In the MEXICO project/MexNext Annex, particle image velocimetry measurements have made it possible to determine...

  18. A guideline for the validation of likelihood ratio methods used for forensic evidence evaluation

    NARCIS (Netherlands)

    Meuwly, Didier; Ramos, Daniel; Haraksim, Rudolf

    2017-01-01

    This Guideline proposes a protocol for the validation of forensic evaluation methods at the source level, using the Likelihood Ratio framework as defined within the Bayes’ inference model. In the context of the inference of identity of source, the Likelihood Ratio is used to evaluate the strength of

  19. The Bland-Altman Method Should Not Be Used in Regression Cross-Validation Studies

    Science.gov (United States)

    O'Connor, Daniel P.; Mahar, Matthew T.; Laughlin, Mitzi S.; Jackson, Andrew S.

    2011-01-01

    The purpose of this study was to demonstrate the bias in the Bland-Altman (BA) limits of agreement method when it is used to validate regression models. Data from 1,158 men were used to develop three regression equations to estimate maximum oxygen uptake (R[superscript 2] = 0.40, 0.61, and 0.82, respectively). The equations were evaluated in a…

  20. Development and validation of HPLC analytical method for quantitative determination of metronidazole in human plasma

    International Nuclear Information System (INIS)

    Safdar, K.A.; Shyum, S.B.; Usman, S.

    2016-01-01

    The objective of the present study was to develop a simple, rapid and sensitive reversed-phase high performance liquid chromatographic (RP-HPLC) analytical method with UV detection system for the quantitative determination of metronidazole in human plasma. The chromatographic separation was performed by using C18 RP column (250mm X 4.6mm, 5 meu m) as stationary phase and 0.01M potassium dihydrogen phosphate buffered at pH 3.0 and acetonitrile (83:17, v/v) as mobile phase at flow rate of 1.0 ml/min. The UV detection was carried out at 320nm. The method was validated as per the US FDA guideline for bioanalytical method validation and was found to be selective without interferences from mobile phase components, impurities and biological matrix. The method found to be linear over the concentration range of 0.2812 meu g/ml to 18.0 meu g/ml (r2 = 0.9987) with adequate level of accuracy and precision. The samples were found to be stable under various recommended laboratory and storage conditions. Therefore, the method can be used with adequate level of confidence and assurance for bioavailability, bioequivalence and other pharmacokinetic studies of metronidazole in human. (author)