WorldWideScience

Sample records for metastasis detection rates

  1. Detection of cancer before distant metastasis

    NARCIS (Netherlands)

    Coumans, F.A.W.; Siesling, Sabine; Terstappen, Leonardus Wendelinus Mathias Marie

    2013-01-01

    Background To establish a distant metastasis (DM) cells must disseminate from the primary tumor and overcome a series of obstacles, the metastatic cascade. In this study we develop a mathematical model for this cascade to estimate the tumor size and the circulating tumor cell (CTC) load before the

  2. Detection of cancer before distant metastasis

    NARCIS (Netherlands)

    Coumans, Frank A. W.; Siesling, Sabine; Terstappen, Leon W. M. M.

    2013-01-01

    Background: To establish a distant metastasis (DM) cells must disseminate from the primary tumor and overcome a series of obstacles, the metastatic cascade. In this study we develop a mathematical model for this cascade to estimate the tumor size and the circulating tumor cell (CTC) load before the

  3. Bone scintigraphy for metastasis detection in canine osteosarcoma

    International Nuclear Information System (INIS)

    Forrest, L.J.; Thrall, D.E.

    1994-01-01

    The purpose of this study was to assess the usefulness of serial bone scintigraphy in the detection of skeletal and extraskeletal metastases in dogs with appendicular osteosarcoma. Twenty-six dogs with primary, appendicular osteosarcoma were entered into a limb-sparing protocol. Bone scintigraphy was performed upon presentation, after neoadjuvant therapy but prior to surgery and at selective intervals after limb-sparing surgery to evaluate for the presence of metastasis. Thoracic radiographs, and radiographs of other sites, were also made at the time of each bone scan. All dogs had a complete necropsy. No dog had bone or lung metastases detected prior to treatment. The bone scans, medical records, and radiographs of each dog were reviewed retrospectively. All but one dog developed metastatic disease. Bone metastatic sites were confirmed at necropsy in 12 of the 26 dogs. Seven of these 12 dogs had bone metastatic sites which were not producing clinical signs, i.e. an occult metastasis. In five of the seven dogs, the occult site was the first metastatic site detected. Extraskeletal metastases were identified scintigraphically in six of the 26 dogs, but these were clinically apparent prior to bone scintigraphy in each dog. Suspected malignant scintigraphic lesions were proven benign in six dogs. In five dogs with malignant bone lesions at necropsy the last bone scan prior to euthanasia was normal. The time interval between scintigraphy and necropsy was variable in these five dogs. All dogs without bone metastases at necropsy had normal bone scans. This study validates the usefulness of bone scintigraphy for detection of occult bone metastasis and improved ability for tumor staging in dogs with appendicular osteosarcoma

  4. Utility of liver scintigraphy and angiography in preoperative detection of liver metastasis from gastrointestinal carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Konomi, K; Aso, M; Nakayama, F [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1980-12-01

    One hundred and seventy cases of cancer of digestive tract were separated into three groups, advanced gastric cancer, biliary and/or pancreatic cancer and colorectal cancer. The presence of liver metastasis in each group was studied preoperatively by either liver scintigraphy or celiac and superior mesenteric angiography. In advanced gastric cancer and colorectal cancer, false negative ranged between 6.7 - 12.7 per cent by both scintigraphy and angiography. In biliary tract and/or pancreatic cancer, the ratio of false negative was significantly higher i.e. 18.8 - 22.6 per cent, which suggests the difficulty in diagnosing liver metastasis correctly in this group. The most frequent occurrences of false positive either in scintigraphy or angiography were those of masses of less than 2 cm in diameter. The difference in correct diagnosis rates for liver metastasis between scintigraphy and angiography in all three groups was only 2.9 per cent. Hence, liver scintigraphy seems to be preferable for the purpose of detecting liver metastasis prior to surgery, since further angiographical examination entails irradiation, possible complications and economic factors.

  5. Pelvic and lumbar metastasis detected by bone scintigraphy in malignant pleural mesothelioma

    International Nuclear Information System (INIS)

    Ruiz Hernandez, G.; Castillo Pallares, F.J.; Llorens Banon, L.; Romero de Avila y Avalos, C.; Garcia Garc'ia, T.; Azagra Ros, P.; Maruenda Paulino, J.I.; Ferrer Albiach, C.

    1999-01-01

    A case of a 43-year-old man suffering from pleural mesothelioma with distant bone metastasis is reported. The results of bone scintigraphy and NMR findings allowed the diagnosis. The current case describes a hematogenous metastasis to the pelvis and vertebral column from a malignant pleural mesothelioma that was detected initally by bone scintigraphy. (orig.) [de

  6. Rate based failure detection

    Science.gov (United States)

    Johnson, Brett Emery Trabun; Gamage, Thoshitha Thanushka; Bakken, David Edward

    2018-01-02

    This disclosure describes, in part, a system management component and failure detection component for use in a power grid data network to identify anomalies within the network and systematically adjust the quality of service of data published by publishers and subscribed to by subscribers within the network. In one implementation, subscribers may identify a desired data rate, a minimum acceptable data rate, desired latency, minimum acceptable latency and a priority for each subscription. The failure detection component may identify an anomaly within the network and a source of the anomaly. Based on the identified anomaly, data rates and or data paths may be adjusted in real-time to ensure that the power grid data network does not become overloaded and/or fail.

  7. Occult Invasive Lobular Carcinoma of Breast Detected by Stomach Metastasis: A Case Report

    International Nuclear Information System (INIS)

    KIm, So Jung; Jung, Hae Kyoung; Ko, Kyung Hee; Yoon, Jung Hyun

    2012-01-01

    Gastric metastasis from primary breast cancer is a rare phenomenon that is more prevalent in the invasive lobular type of breast cancer. We describe a very rare case of occult invasive lobular cancer of the breast detected by the initial presentation of gastric metastasis in a patient without a history of breast cancer. A 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (FDG PET/CT) which showed increased FDG uptake in the stomach, abdominal mesentery and the right breast, and played pivotal roles in the detection of occult primary breast cancer and a diagnosis of gastric metastasis as an ancillary method for obtaining histological results and immunohistochemical stains.

  8. Occult Invasive Lobular Carcinoma of Breast Detected by Stomach Metastasis: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    KIm, So Jung; Jung, Hae Kyoung; Ko, Kyung Hee; Yoon, Jung Hyun [Dept. of Radiology, Bundang CHA general Hospital, CHA University College of Medicine, Seongnam (Korea, Republic of)

    2012-02-15

    Gastric metastasis from primary breast cancer is a rare phenomenon that is more prevalent in the invasive lobular type of breast cancer. We describe a very rare case of occult invasive lobular cancer of the breast detected by the initial presentation of gastric metastasis in a patient without a history of breast cancer. A 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (FDG PET/CT) which showed increased FDG uptake in the stomach, abdominal mesentery and the right breast, and played pivotal roles in the detection of occult primary breast cancer and a diagnosis of gastric metastasis as an ancillary method for obtaining histological results and immunohistochemical stains.

  9. 18F-DG PET/CT in detection of recurrence and metastasis of colorectal cancer

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    AIM: To evaluate the value of 18F-DG PET/CT in detecting recurrence and/or metastasis of colorectal cancer (CRC).METHODS: Combined visual analysis with semiquantitative analysis, the 18F-DG PET/CT wholebody imaging results and the corresponding clinical data of 68 postoperative CRC patients including 48 male and 20 female with average age of 58.1 were analyzed retrospectively.RESULTS: Recurrence and/or metastasis were confirmed in 56 patients in the clinical follow-up after the PET/CT imaging. The sensitivity of PET/CT diagnosis of CRC recurrence and/or metastasis was 94.6%, and the specificity was 83.3%. The positive predictive value (PPV)was 96.4% and the negative predictive value (NPV) was 76.9%. PET/CT imaging detected one or more occult malignant lesions in 8 cases where abdominal/pelvic CT and/or ultrasonography showed negative findings, and also detected more lesions than CT or ultrasonography did in 30.4% (17/56) cases. Recurrence and/or metastasis was detected in 91.7% (22/24) cases with elevated serum CEA levels by 18F-DG PET/CT imaging.CONCLUSION: 18F-DG PET/CT could detect the recurrence and/or metastasis of CRC with high sensitivity and specificity.

  10. MR imaging of bone marrow metastasis in patients with neuroblastoma. Comparison between mass-screened cases and clinically detected cases

    International Nuclear Information System (INIS)

    Kanegawa, Kimio; Akasaka, Yoshinori; Kawasaki, Ryuta; Nishiyama, Shoji; Mabuchi, Osamu; Muraji, Toshihiro

    1999-01-01

    Seventy-six patients with neuroblastoma who underwent bone marrow MRI were divided into two groups: the first group consisted of patients detected by mass screening (M group, n=55), and the second group of patients detected clinically (non-M group, n=21). Bone marrow metastasis was morphologically classified into two types, nodular type and diffuse type. We studied the incidence of bone marrow metastasis, relationship between the patterns of bone marrow metastasis and the presence of bone metastasis, and morphological changes of bone marrow metastasis after chemotherapy. In M group, the incidence of bone marrow metastasis was 7.3% (4 patients) and the patterns of bone marrow metastases were all nodular type not accompanied with bone metastasis and disappeared after chemotherapy. In non-M group, the incidence of bone marrow metastasis was 52.4% (11 patients). Bone marrow metastases had both patterns of metastasis. Forty-five per cent of diffuse type of bone marrow metastasis were accompanied with bone metastasis. All bone marrow metastases disappeared after chemotherapy, but in one of 11, there was recurrence of bone marrow metastasis. (author)

  11. Significance of SYT8 For the Detection, Prediction, and Treatment of Peritoneal Metastasis From Gastric Cancer.

    Science.gov (United States)

    Kanda, Mitsuro; Shimizu, Dai; Tanaka, Haruyoshi; Tanaka, Chie; Kobayashi, Daisuke; Hayashi, Masamichi; Iwata, Naoki; Niwa, Yukiko; Yamada, Suguru; Fujii, Tsutomu; Sugimoto, Hiroyuki; Murotani, Kenta; Fujiwara, Michitaka; Kodera, Yasuhiro

    2018-03-01

    prolonged survival of mice engrafted with GC cells. SYT8 represents a promising target for the detection, prediction, and treatment of peritoneal metastasis of GC.

  12. Pelvic and lumbar metastasis detected by bone scintigraphy in malignant pleural mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz Hernandez, G.; Castillo Pallares, F.J.; Llorens Banon, L.; Romero de Avila y Avalos, C. [Hospital Clinic Universitari de Valencia (Spain). Servei de Medicina Nuclear; Garcia Garc`ia, T.; Azagra Ros, P. [Hospital Clinic Universitari de Valencia (Spain). Servei d`Oncologia; Maruenda Paulino, J.I. [Hospital Clinic Universitari de Valencia (Spain). Servei Traumatologia; Ferrer Albiach, C. [Hospital Clinic Universitari de Valencia (Spain). Servei Radioterapia

    1999-05-01

    A case of a 43-year-old man suffering from pleural mesothelioma with distant bone metastasis is reported. The results of bone scintigraphy and NMR findings allowed the diagnosis. The current case describes a hematogenous metastasis to the pelvis and vertebral column from a malignant pleural mesothelioma that was detected initally by bone scintigraphy. (orig.) [Deutsch] Fallbericht ueber einen 43jaehrigen Mann mit Pleural-Mesotheliom und Knochenmetastasen. Die Diagnose wurde durch Knochenszintigraphie und NMR gestellt. Der vorliegende Fall beschreibt die haematogene Metastasierung ins Becken und in die Wirbelsaeule, ausgehend von einem malignen Pleural-Mesotheliom, das urspruenglich durch Knochenszintigraphie diagnostiziert wurde. (orig.)

  13. Detection of Thyroid Metastasis pf Renal Transitional Cell Carcinoma Using FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Il; Kim, Yu Kyeong; Kim, Sang Eun [Seoul National Univ. Bundang Hospital, Seoul (Korea, Republic of); Lee, Jong Jin [Univ. of Ulsan College of Medicine, Seoul (Korea, Republic of); Paik, Jin Ho [Seoul National Univ. Bundang Hospital, Seoul (Korea, Republic of)

    2011-06-15

    A 69 year old man who was diagnosed with renal transitional cell carcinoma (TCC) underwent F 18 fluorodeoxyglucose (FDG) positron emission tomography with computed tomography (PET/CT) for detecting recurrence after chemotherapy. FDG PET/CT revealed multiple new hypermetabolic lesions in many places, including the right thyroid gland. Biopsy of the thyroid lesion was performed,and a diagnosis of metastatic TCC was made. We could detect thyroid metastasis of renal TCC by FDG PET/CT.

  14. Diffusion-weighted MRI for uveal melanoma liver metastasis detection

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Mathilde; Petras, Slavomir; Servois, Vincent [Institut Curie, Department of Radiology and Nuclear Medicine, Paris (France); Mariani, Pascale; Cassoux, Nathalie [Institut Curie, Department of Surgery, Paris (France); Bidard, Francois Clement; Rodrigues, Manuel Jorge; Piperno-Neumann, Sophie [Institut Curie, Department of Medical Oncology, Paris (France); Farkhondeh, Fereshteh [Institut Curie, Department of Pathology, Paris (France)

    2015-08-15

    We aimed to assess the sensitivity of diffusion-weighted (DW) magnetic resonance (MR) imaging for the detection of pathologically confirmed uveal melanoma liver metastases (UMLM). Twenty patients who underwent complete surgical resection of their UMLM (N = 83) were included. Pre-surgery liver MR imaging included T2-weighted, T1-weighted, DW and dynamic-gadolinium-enhanced MR sequences. Two radiologists independently reviewed three sets of images (DW / morphologic-dynamic / combined) for each patient using intraoperative and pathological findings as a standard of reference. The sensitivities of the morphologic-dynamic and DW images for UMLM detection were 63 % and 59 %, respectively, for reader 1 (R1) and 64 % and 53 %, for reader 2 (R2). Sensitivity of the combined set was higher than sensitivity in the two other sets (R1:69 %, R2:67 %), but was only significantly different than the sensitivity of the DW images (McNemar test). For the three sets and the two readers, the sensitivity for UMLM smaller than 5 mm (37-46 %) was significantly lower than that for UMLM larger than 5 mm (67-90 %). The sensitivity for UMLM located in the subcapsular area (41-54 %) was significantly lower than that for intraparenchymal UMLM (68-86 %) (Chi-square test). Our study shows that the addition of DW imaging to morphologic-dynamic images does not significantly increase MR sensitivities for UMLM detection. (orig.)

  15. Utility of liver scintigraphy and angiography in preoperative detection of liver metastasis from gastrointestinal carcinoma

    International Nuclear Information System (INIS)

    Konomi, Kohki; Aso, Masakazu; Nakayama, Fumio

    1980-01-01

    One hundred and seventy cases of cancer of digestive tract were separated into three groups, advanced gastric cancer, biliary and/or pancreatic cancer and colorectal cancer. The presence of liver metastasis in each group was studied properatively by either liver scintigraphy or celiac and superior mesenteric angiography. In advanced gastric cancer and colorectal cancer, false negative ranged between 6.7 - 12.7 per cent by both scintigraphy and angiography. In biliary tract and/or pancreatic cancer, the ratio of false negative was significantly higher i.e. 18.8 - 22.6 per cent, which suggests the difficulty in diagnosing liver metastasis correctly in this group. The moist frequent occurrences of false positive either in scintigraphy or angiography were those of masses of less than 2 cm in diameter. The difference in correct diagnosis ratio for liver metastasis between scintigraphy and angiography in all three groups was only 2.9 per cent. Hence, liver scintigraphy seems to be preferable for the purpose of detecting liver metastasis prior to surgery, since further angiographical examination entails irradiation, possible complications and economic factors. (author)

  16. Detection of bone metastasis of prostate cancer. Comparison of whole-body MRI and bone scintigraphy

    International Nuclear Information System (INIS)

    Ketelsen, D.; Roethke, M.; Aschoff, P.; Lichy, M.P.; Claussen, C.D.; Schlemmer, H.P.; Merseburger, A.S.; Reimold, M.

    2008-01-01

    Purpose: prostate cancer continues to be the third leading cancer-related mortality of western men. Early diagnosis of bone metastasis is important for the therapy regime and for assessing the prognosis. The standard method is bone scintigraphy. Whole-body MRI proved to be more sensitive for early detection of skeletal metastasis. However, studies of homogenous tumor entities are not available. The aim of the study was to compare bone scintigraphy and whole-body MRI regarding the detection of bone metastasis of prostate cancer. Materials and methods: 14 patients with histologically confirmed prostate cancer and a bone scintigraphy as well as whole-body MRI within one month were included. The mean age was 68 years. Scintigraphy was performed using the planar whole-body technique (ventral and dorsal projections). Suspect areas were enlarged. Whole-body MRI was conducted using native T1w and STIR sequences in the coronary plane of the whole body, sagittal imaging of spine and breath-hold STIR and T1w-Flash-2D sequences of ribs and chest. Bone scintigraphy and whole-body MRI were evaluated retrospectively by experienced radiologists in a consensus reading on a lesion-based level. Results: whole-body MRI detected significantly more bone metastasis (p = 0.024). 96.4% of the demonstrated skeletal metastases in bone scintigraphy were founded in whole-body MRI while only 58.6% of the depicted metastases in MRI were able to be located in scintigraphy. There was no significant difference regarding bone metastasis greater than one centimeter (p = 0.082) in contrast to metastasis less than one centimeter (p = 0.035). Small osteoblastic metastases showed a considerably higher contrast in T1w sequences than in STIR imaging. Further advantages of whole-body MRI were additional information about extra-osseous tumor infiltration and their complications, for example stenosis of spinal canal or vertebral body fractures, found in 42.9% of patients. (orig.)

  17. The usefulness of bone marrow scintigraphy in the detection of bone metastasis from prostatic cancer

    International Nuclear Information System (INIS)

    Otsuka, Nobuaki; Fukunaga, Masao; Morita, Rikushi

    1985-01-01

    A combination study of bone and bone marrow scintigraphy was performed on 25 pts with prostatic cancer, and, in order to study the usefulness in the diagnosis of bone metastasis, the findings of 2 scintigraphies were compared with those of skeletal roentgenography. Out of the 18 cases with the hot spots of sup(99m)Tc-MDP in the lower lumbar spine or/and the pelvic bone, 8 showed normal bone marrow scintigrams which were eventually proved to have degenerative changes of the spine accompanied by aging. On the other hand, nine cases of the ten, who had accumulation defects on the bone marrow scintigrams were finally proved having bone metastasis. All six cases with extensive bone metastases shown by bone scintigraphy with sup(99m)Tc-MDP, demonstrated multiple accumulation defects on bone marrow scintigraphy with sup(99m)Tc-sulfur colloid. In conclusion, bone marrow scintigraphy was thought to be helpful in distinguishing the metastatic lesions from the benign spinal degenerative changes in the cases with suspicions bone involvement and in evaluating equivocal lesions in the pelvis. Therefore, it was shown that, in the detection and diagnosis of bone metastasis from prostatic cancer, bone scintigraphy alone was insufficient, and that combination with bone marrow scintigraphy was found to be useful. (author)

  18. Detection of hepatic metastasis: Manganese- and ferucarbotran-enhanced MR imaging

    International Nuclear Information System (INIS)

    Choi, Jin-Young; Kim, Myeong-Jin; Kim, Joo Hee; Kim, Seung Hyoung; Ko, Heung-Kyu; Lim, Joon Seok; Oh, Young Taik; Chung, Jae-Joon; Yoo, Hyung Sik; Lee, Jong Tae; Kim, Ki Whang

    2006-01-01

    Purpose: To compare the mangafodipir trisodium (MnDPDP)-enhanced and ferucarbotran-enhanced magnetic resonance imaging (MRI) for the detection of hepatic metastases. Material and methods: Twenty patients with known hepatic metastasis underwent MR imaging using mangafodipir trisodium and ferucarbotran in at least 1-day intervals. Thirty-eight metastases were confirmed either histologically or clinically. Two radiologists independently reviewed the MnDPDP-enhanced and ferucarbotran-enhanced sets in a random order. The sensitivity and accuracy of lesion detection and the ability to distinguish a benign lesion from a malignant lesion were compared by the areas (Az) under the receiver operating characteristic (ROC) curve. The lesion-liver contrast-to-noise ratios (CNR) were compared by paired t-test. Results: The overall accuracy for detecting metastases was not significantly different between the MnDPDP set (Az = 0.912 and 0.913 for reader 1 and 2, respectively) and the SPIO set (Az = 0.920 and 0.950). The CNR at the MnDPDP-enhanced images and the SPIO-enhanced images were not significantly different (P = 0.146). Conclusion: Both MnDPDP- and ferucarbotran-enhanced MRI have a comparable accuracy in detecting hepatic metastasis

  19. Comparison of whole body MR diffusion weighted imaging and skeletal scintigraphy in detecting bone metastasis

    International Nuclear Information System (INIS)

    Xu Xian; Ma Lin; Zhang Jinshan; Cai Youquan; Cheng Liuquan; Guo Xinggao; Xu Baixuan

    2008-01-01

    Objective: To evaluate the application of whole body MR diffusion weighted imaging (DWI) in the detection of bone metastasis using skeletal scintigraphy as the reference. Methods: Forty-two healthy volunteers and 38 patients with malignant tumors were enrolled in our study. All the patients received MR examination and skeletal scintigraphy within one week. MR examination was performed on GE signa 3.0T MR scanner using a build-in body coil. The skeletal system was divided into eight regions and the images of the whole body MR DWI and skeletal scintigraphy were reviewed to compare the two modalities patient by patient and region by region. The images were reviewed separately by two radiologists and two nuclear medicine physicians, who were blinded to the results of another imaging modality. Results: A total of 169 metastatic lesions in 69 regions of 30 patients were detected by whole body MR DWI while 156 lesions in 68 regions of 29 patients were identified by skeletal scintigraphy. There were two cases negative in scintigraphy but positive in whole body MR DWI and one case positive in scintigraphy only. There were eight lesions negative in scintigraphy but positive in whole body MR DWI, mainly located in the spine, pelvis and femur. Seven lesions were only detected by scintigraphy, mainly located in the skull, sternum, clavicle and scapula. Conclusion: The whole body MR DWI reveals excellent consistency with skeletal scintigraphy regarding bone metastasis, and the two modalities are complementary for each other. (authors)

  20. Comparison of CT and 18F-FDG PET for Detecting Peritoneal Metastasis on the Preoperative Evaluation for Gastric Carcinoma

    International Nuclear Information System (INIS)

    Lim, Joon Seok; Kim, Myeong Jin; Yun, Mi jin

    2006-01-01

    The aim of our study was to compare the accuracy of CT and 18 F-FDG PET for detecting peritoneal metastasis in patients with gastric carcinoma. One-hundred-twelve patients who underwent a histologic confirmative exam or treatment (laparotomy, n = 107; diagnostic laparoscopy, n = 4; peritoneal washing cytology, n = 1) were retrospectively enrolled. All the patients underwent CT and 18 F-FDG PET scanning for their preoperative evaluation. The sensitivities, specificities and accuracies of CT and 18 FFDG PET imaging for the detection of peritoneal metastasis were calculated and then compared using Fisher's exact probability test (p 18 F-FDG PET imaging for detecting peritoneal metastasis. Based on the original preoperative reports, CT and 18 F-FDG PET showed sensitivities of 76.5% and 35.3% (p = 0.037), specificities of 91.6% and 98.9% (p = 0.035), respectively, and equal accuracies of 89.3% (p = 1.0). The receptor operating characteristics curve analysis showed a significantly higher diagnostic performance for CT (Az 0.878) than for PET (Az = 0.686) (p 0.004). The interobserver agreement for detecting peritoneal metastasis was good (κ value = 0.684) for CT and moderate ((κ value = 0.460) for PET. For the detection of peritoneal metastasis, CT was more sensitive and showed a higher diagnostic performance than PET, although CT had a relatively lower specificity than did PET

  1. Combined detection of Twist1, Snail1 and squamous cell carcinoma antigen for the prognostic evaluation of invasion and metastasis in cervical squamous cell carcinoma.

    Science.gov (United States)

    Yang, Huilun; Hu, Haiyang; Gou, Yanling; Hu, Yuhong; Li, Hui; Zhao, Hongwei; Wang, Beidi; Li, Peiling; Zhang, Zongfeng

    2018-04-01

    Cervical cancer is one of the most common malignant tumours of the female reproductive system, ranking second only to breast cancer in morbidity worldwide. Essential features of the progression of cervical cancer are invasion and metastasis, which are closely related to disease prognosis and mortality rate. At the present time there is no effective method to evaluate cancer invasion and metastasis before surgery. Here we report our study on molecular changes in biopsy tissue for the prognostic evaluation of cancer invasion and metastasis. Expression of the epithelial-mesenchymal transition-inducing transcription factors Twist1 and Snail1 was detected by immunohistochemistry in 32 normal, 36 low-grade squamous intraepithelial neoplasia (LSIL), 54 high-grade squamous intraepithelial neoplasia (HSIL) and 320 cervical squamous cell carcinoma (CSCC) samples. The correlation between the expression of Twist1, Snail1 and squamous cell carcinoma antigen (SCCA) in CSCC tissues and clinical pathology results was evaluated. A transwell migration and invasion assay was used to explore the roles of Twist1 and Snail1 in the invasion of cancer cells. Lymph node metastasis and lymphovascular space invasion (LVSI) rates for the following groups were analysed: SCCA(+) group, Twist1(+) group, Snail1(+) group, Twist1(+)Snail1(+)group, Twist1(+)SCCA(+)group, Snail1(+)SCCA(+)group and Twist1(+)Snail1(+)SCCA(+) group. The expression of Twist1 and Snail1 was significantly upregulated in HSIL and CSCC (p  0.05). The expression of SCCA was associated with LVSI, lymph node metastasis, FIGO stage and histological grade (p  0.05). Twist1 was an independent factor contributing to the invasion ability of cervical cancer cells. In addition, the positive rate of lymph node metastasis and LVSI was higher in the Twist1(+)Snail1(+)SCCA(+) group than in the SCCA(+) group, Twist1(+) group and Snail1(+) group, respectively (p < 0.05). Combined detection of Twist1 and Snail1 in SCCA-positive biopsy

  2. Usefulness of low-dose CT in the detection of pulmonary metastasis of gestational trophoblastic tumours

    International Nuclear Information System (INIS)

    Xu, X.J.; Lou, F.L.; Zhang, M.M.; Pan, Z.M.; Zhang, L.

    2007-01-01

    Aim: To determine whether a low-dose spiral chest computed tomography (CT) examination could replace standard-dose chest CT in detecting pulmonary metastases in patients with gestational trophoblastic tumour (GTT). Materials and methods: In a prospective investigation, 67 chest CT examinations of 39 GTT patients were undertaken. All the patients underwent CT examinations using standard-dose (150 mAs, pitch 1, standard reconstruction algorithm) and low-dose (40 mAs, pitch 2, bone reconstruction algorithm) protocols. Two radiologists interpreted images independently. A metastasis was defined as a nodule within lung parenchyma that could not be attributed to a pulmonary vessel. The number of metastases detected with each protocol was recorded. The size of each lesion was measured and categorized as <5, 5-9.9, and ≥10 mm. Wilcoxon's signed rank test was used to assess the difference between the numbers of lesion detected by the two protocols. Results: The CT dose index (CTDI) for the standard-dose and low-dose CT protocols was 10.4 mGy and 1.4 mGy, respectively. One thousand, six hundred, and eighty-two metastases were detected by standard-dose CT, and 1460 lesions by the low-dose protocol. The numbers detected by low-dose CT were significantly less than those detected by standard-dose CT (Z = -3.776, p < 0.001), especially for nodules smaller than 5 mm (Z = -4.167, p < 0.001). However, the disease staging and risk score of the patients were not affected by use of the low-dose protocol. Conclusion: Low-dose chest CT can be used as a staging and follow-up procedure for patients with GTT

  3. Efficacy and feasibility of the immunomagnetic separation based diagnosis for detecting sentinel lymph node metastasis from breast cancer

    Directory of Open Access Journals (Sweden)

    Zhi XC

    2015-04-01

    Full Text Available Xiang-Cheng Zhi,1–3,* Min Zhang,1–3,* Ting-Ting Meng,1–3,* Xiao-Bei Zhang,1–3 Zhen-Dong Shi,1–3 Yan Liu,1–3 Jing-Jing Liu,1–3 Sheng Zhang,1–3 Jin Zhang1–3 1Third Department of Breast Cancer, People’s Republic of China Tianjin Breast Cancer Prevention, Treatment and Research Center, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center of Cancer, Tianjin, People’s Republic of China; 2Key Laboratory of Breast Cancer Prevention and Therapy of the Ministry of Education, Tianjin, People’s Republic of China; 3Key Laboratory of Cancer Prevention and Therapy, Tianjin, People’s Republic of China *These authors contributed equally to this work Abstract: A purpose of this study was to establish a novel molecular diagnostic model and provide new insight into the intraoperative evaluation of the sentinel lymph node (SLN metastasis in breast cancer. A total of 124 breast cancer patients who met the criteria of sentinel lymph node biopsy (SLNB and underwent intraoperative biopsy were consecutively enrolled in this study. After the SLNs obtained from each patient were labeled, MOC-31 monoclonal antibody-mediated immunomagnetic separation (IMS and flow cytometry were used to determine the expressions of breast cancer metastasis-related markers, including Mucin 1 (MUC1, CD44v6, and HER2. Alternatively, conventional intraoperative hematoxylin and eosin (HE staining and cytokeratin immunohistochemistry (CK-IHC were performed to detect potential SLN metastasis. The sensitivity, specificity, and false-negative rate of the three intraoperative diagnostic methods were compared and analyzed. A total of 55 positive-SLNs were found in 38 breast cancer patients using IMS, yielding a sensitivity of 86.4% (38/44, specificity of 94.7% (36/38, accuracy of 93.5% (116/124, false-positive rate of 2.5% (2/80, false-negative rate of 13.6% (6/44, positive predictive value of 95.5% (42/44, and negative predictive value

  4. Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study.

    Directory of Open Access Journals (Sweden)

    Leonard Sunwoo

    Full Text Available To assess the effect of computer-aided detection (CAD of brain metastasis (BM on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR imaging using follow-up imaging and consensus as the reference standard.The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC method was used to determine the improvement in the diagnostic accuracy.The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM of 0.874 (without CAD vs. 0.898 (with CAD according to JAFROC analysis (p < 0.01. Statistically significant improvement was noted only for less-experienced reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p < 0.01. The additional time required to review the CAD results was approximately 72 sec (40% of the total review time.CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.

  5. Computer-aided detection of brain metastasis on 3D MR imaging: Observer performance study.

    Science.gov (United States)

    Sunwoo, Leonard; Kim, Young Jae; Choi, Seung Hong; Kim, Kwang-Gi; Kang, Ji Hee; Kang, Yeonah; Bae, Yun Jung; Yoo, Roh-Eul; Kim, Jihang; Lee, Kyong Joon; Lee, Seung Hyun; Choi, Byung Se; Jung, Cheolkyu; Sohn, Chul-Ho; Kim, Jae Hyoung

    2017-01-01

    To assess the effect of computer-aided detection (CAD) of brain metastasis (BM) on radiologists' diagnostic performance in interpreting three-dimensional brain magnetic resonance (MR) imaging using follow-up imaging and consensus as the reference standard. The institutional review board approved this retrospective study. The study cohort consisted of 110 consecutive patients with BM and 30 patients without BM. The training data set included MR images of 80 patients with 450 BM nodules. The test set included MR images of 30 patients with 134 BM nodules and 30 patients without BM. We developed a CAD system for BM detection using template-matching and K-means clustering algorithms for candidate detection and an artificial neural network for false-positive reduction. Four reviewers (two neuroradiologists and two radiology residents) interpreted the test set images before and after the use of CAD in a sequential manner. The sensitivity, false positive (FP) per case, and reading time were analyzed. A jackknife free-response receiver operating characteristic (JAFROC) method was used to determine the improvement in the diagnostic accuracy. The sensitivity of CAD was 87.3% with an FP per case of 302.4. CAD significantly improved the diagnostic performance of the four reviewers with a figure-of-merit (FOM) of 0.874 (without CAD) vs. 0.898 (with CAD) according to JAFROC analysis (p reviewers (FOM without vs. with CAD, 0.834 vs. 0.877, p review the CAD results was approximately 72 sec (40% of the total review time). CAD as a second reader helps radiologists improve their diagnostic performance in the detection of BM on MR imaging, particularly for less-experienced reviewers.

  6. Detecting metastasis of gastric carcinoma using high-resolution micro-CT system: in vivo small animal study

    Science.gov (United States)

    Liu, Junting; Tian, Jie; Liang, Jimin; Li, Xiangsi; Yang, Xiang; Chen, Xiaofeng; Chen, Yi; Zhou, Yuanfang; Wang, Xiaorui

    2011-03-01

    Immunocytochemical and immunofluorescence staining are used for identifying the characteristics of metastasis in traditional ways. Micro-computed tomography (micro-CT) is a useful tool for monitoring and longitudinal imaging of tumor in small animal in vivo. In present study, we evaluated the feasibility of the detection for metastasis of gastric carcinoma by high-resolution micro-CT system with omnipaque accumulative enhancement method in the organs. Firstly, a high-resolution micro-CT ZKKS-MCT-sharp micro-CT was developed by our research group and Guangzhou Zhongke Kaisheng Medical Technology Co., Ltd. Secondly, several gastric carcinoma models were established through inoculating 2x106 BGC-823 gastric carcinoma cells subcutaneously. Thirdly, micro-CT scanning was performed after accumulative enhancement method of intraperitoneal injection of omnipaque contrast agent containing 360 mg iodine with a concentration of 350 mg I/ml. Finally, we obtained high-resolution anatomical information of the metastasis in vivo in a BALB/c NuNu nude mouse, the 3D tumor architecture is revealed in exquisite detail at about 35 μm spatial resolution. In addition, the accurate shape and volume of the micrometastasis as small as 0.78 mm3 can be calculated with our software. Overall, our data suggest that this imaging approach and system could be used to enhance the understanding of tumor proliferation, metastasis and could be the basis for evaluating anti-tumor therapies.

  7. Metastasis of Breast Carcinoma to Intercostal Muscle Detected by Breast MRI: A Case Report

    International Nuclear Information System (INIS)

    Cho, Kyung Eun; Son, Eun Ju; Kim, Jeong Ah; Youk, Ji Hyun; Kim, Eun Kyung; Kwak, Jin Young; Jeong, Joon

    2010-01-01

    Breast cancer can metastasize to any organ; however, distant metastases are unusual at the time of diagnosis. Furthermore metastasis to skeletal muscle is an uncommon manifestation of malignancy. We report a case of a 45-year-old woman diagnosed with cancer of the left breast with metastases to the ipsilateral intercostal muscle. To the best of our knowledge this is the first report of intercostal muscle metastasis from breast cancer in the English literature

  8. Evaluation of 18F-FDG PET/CT Parameters for Detection of Lymph Node Metastasis in Cutaneous Melanoma.

    Science.gov (United States)

    Cha, Jongtae; Kim, Soyoung; Wang, Jiyoung; Yun, Mijin; Cho, Arthur

    2018-02-01

    The purpose of this study was to investigate the value of 18 F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) parameters in the detection of regional lymph node (LN) metastasis in patients with cutaneous melanoma. We evaluated patients with cutaneous melanoma who underwent FDG PET/CT for initial staging or recurrence evaluation. A total of 103 patients were enrolled, and 165 LNs were evaluated. LNs that were confirmed pathologically or by follow-up imaging were included in this study. PET parameters, including maximum standardized uptake value (SUVmax), total lesion glycolysis and tumour-to-liver ratio, were used to determine the presence of metastases, and the results were compared with CT-determined LN metastasis. Receiver operating characteristic (ROC) curve analysis was used to determine the optimal cut-off values of the FDG PET parameters. A total of 93 LNs were malignant, and 84 LNs were smaller than 10 mm. In all 165 LNs, an SUVmax of >2.51 showed a sensitivity of 73.1%, a specificity of 88.9%, and an accuracy of 80.0% in detecting metastatic LNs. CT showed a higher specificity (87.3%) and lower accuracy (65.5%). For non-enlarged regional LNs (2.4 showed a high sensitivity (91%) and accuracy (89%) in detecting metastasis in LNs ≥1 cm, and LNs <1 cm with an SUVmax <1.4 were likely to be benign.

  9. Incidentally Detected Inoperable Malignant Pheochromocytoma with Hepatic Metastasis Treated by Transcatheter Arterial Chemoembolization

    Directory of Open Access Journals (Sweden)

    Joong Keun Kim

    2014-12-01

    Full Text Available Malignant pheochromocytoma (PCC is a rare condition. Although the liver is the second most frequent site of metastasis in malignant PCC, no definite treatments have been established. Herein, we report a case of liver metastasis of PCC that was successfully treated by transcatheter arterial chemoembolization (TACE. A 69-year-old man was admitted to the Department of Gastroenterology for evaluation of an incidental hepatic mass in August 2013. He had undergone right adrenalectomy in May 2005 and PCC had been confirmed on the basis of histopathological findings. Liver biopsy was performed, and metastatic PCC was diagnosed. The lesion appeared inoperable because of invasion of the portal vein and metastases in the lymph nodes along the hepatoduodenal ligament. Thus, TACE was performed instead. After TACE, symptoms including dizziness and cold sweating improved, and the patient's serum catecholamine levels decreased. On the basis of this case, we believe that TACE may be a useful treatment for liver metastasis in malignant PCC.

  10. Diagnostic efficacy of the preoperative lymphoscintigraphy, Ga-67 scintigraphy and computed tomography for detection of lymph node metastasis in cases with ovarian or endometrial carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Ozalp, S.; Yalcin, O.T.; Polay, S. [Osmangazi Univ. School of Medicine, Dept. of Obstetrics and Gynecology, Eskisehir (Turkey); Aslan, N.; Vardareli, E. [Osmangazi Univ. School of Medicine, Dept. of Nuclear Medicine, Eskisehir (Turkey); Adapinar, B. [Osmangazi Univ. School of Medicine, Dept. of Radiology, Eskisehir (Turkey)

    1999-02-01

    Background: To investigate the diagnostic efficacy of preoperative lymphoscintigraphy (LS), Ga-67 scintigraphy (GS) and computed tomography (CT) for detection of lymph node metastasis in patients with endometrial or ovarian carcinoma. Methods: The results of preoperative LS, GS and CT used to detect lymph node metastasis were compared to the postoperative histopathological results of lymph node dissection materials of a total of 37 patients, including 16 patients with endometrial and 21 patients with ovarian carcinomas. The diagnostic efficacy of these methods for detecting lymph node metastasis were calculated. Results: When the results of all of the patients were taken into account, the preoperative LS, GS and CT were found to have sensitivities of 50%, 20% and 40% and specificities of 51.8%, 96.3%, and 92.6%, respectively, for detection of pelvic lymph node metastasis. The same methods had sensitivities of 27.3%, 27.3% and 72.7% and specificities of 88.5%, 88.5%, 84.6%, respectively, for detecting para-aortic lymph node metastasis in all patients. Conclusion: These data suggested that although LS, GS and CT had relatively high specificity, low sensitivity of these imaging methods precluded their routine preoperative use for diagnosis of lymph node metastasis of ovarian or endometrial carcinoma. (au) 22 refs.

  11. Detection of penile metastasis from bladder cancer using F 18 FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Yun; Lee, Jong Jin [Univ. of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2012-12-15

    A 74 year old man who had experienced priapism for 2 months after radical cystectomy for bladder cancer visited our hospital, and underwent metastatic work up {sup 18}F fluorodeoxyglucose (FDG) positron emission tomography/computed tomography(PET/CT)showed diffuse hypermetabolic activity along the penis shaft, which was confirmed as a penile metastasis.

  12. FDG-PET-Detected Extracranial Metastasis in Patients with Non-Small Cell Lung Cancer Undergoing Staging for Surgery or Radical Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Macmanus, Michael P.; Hicks, Rodney; Fisher, Richard; Rischin, Danny; Michael, Michael; Wirth, Andrew; Ball, David L. [Peter MacCallum Cancer Inst., Melbourne (Australia). Dept. of Radiation Oncology

    2003-03-01

    The prognostic significance of extracranial distant metastasis detected by positron emission tomography (PET) was investigated in patients with non-small cell lung cancer (NSCLC). Forty-two patients staged with 18F-fluorodeoxyglucose-PET-detected distant metastasis before planned surgery (n=7) or radical radiotherapy (RT)/chemoradiotherapy (n=35) for NSCLC were identified from a prospective database. The influence of metastasis number and other prognostic factors was investigated using Cox's regression analysis. Treatment after PET included surgery (n=2), radical RT (n =5), palliative RT (n=25), chemotherapy (n=8) or supportive care (n=2). All but 4 patients had died by the last follow-up. Median survival was 9 months overall, 12 months for 27 patients with single PET-detected metastasis and 5 months for 15 patients with >1 metastasis (p=0.009). It was found that the Eastern Cooperative Oncology Group performance status (p=0.027) but not pre-PET stage, weight loss or metastasis site correlated with survival. PET-detected metastatic tumor burden appeared to influence survival and should be evaluated as a prognostic factor in NSCLC.

  13. A comparative study of FDG PET/CT and enhanced multi-detector CT for detecting liver metastasis according to the size and location.

    Science.gov (United States)

    Park, Jung Mi; Kim, Il Young; Kim, Sang Won; Lee, Sang Mi; Kim, Hyun Gi; Kim, Shin Young; Shin, Hyung Chul

    2013-04-01

    The aim of this study was to compare the diagnosability between (18)F-fluorodeoxyglucose (FDG) PET/CT and enhanced multi-detector CT (MDCT) for the detection of liver metastasis (LM) according to the size and location in liver and to evaluate standard maximum standardized uptake values (SUVmax) of all liver metastatic lesions. One hundred two consecutive patients with malignancy who underwent both FDG PET/CT and MDCT for LM evaluation were retrospectively reviewed. Among them, 56 patients with LM were enrolled in this study. LM was confirmed by follow-up imaging studies after at least 6 months or by histopathology. FDG PET/CT and MDCT images were visually analyzed using three-point scale by the consensus of two radiologists and two nuclear medicine physicians. The size and location (central vs. sub-capsular) of the all liver lesions were evaluated using MDCT images. Furthermore, SUVmax of all liver lesions on FDG PET/CT images were calculated. A total of 146 liver lesions were detected by FDG PET/CT and MDCT and 142 of the lesions were diagnosed as LM. The detection rates of MDCT and FDG PET/CT for LM by visual analysis were 77 and 78%, respectively. There was no significant difference of detection rate according to the overall location and size of the lesions. However, FDG PET/CT was more sensitive than MDCT for detecting small and sub-capsular LM. The detection rate of FDG PET/CT for LM was 68% by the cutoff SUVmax of 2.7. Although the diagnosabilities of MDCT and FDG PET/CT for detecting LM were comparable, FDG PET/CT is superior to MDCT for detecting small LM located in the sub-capsular portion of liver.

  14. Leak rate models and leak detection

    International Nuclear Information System (INIS)

    1992-01-01

    Leak detection may be carried out by a number of detection systems, but selection of the systems must be carefully adapted to the fluid state and the location of the leak in the reactor coolant system. Computer programs for the calculation of leak rates contain different models to take into account the fluid state before its entrance into the crack, and they have to be verified by experiments; agreement between experiments and calculations is generally not satisfactory for very small leak rates resulting from narrow cracks or from a closing bending moment

  15. The Clinical Value of Axillary Ultrasonogra- phy for Detection of Axillary Lymph Node Metastasis in Cases with Breast Cancer

    Directory of Open Access Journals (Sweden)

    Sedigheh Tahmasebi

    2014-10-01

    Full Text Available Background: The axillary lymph node stage is one of the single most important determinants in the prognosis of breast cancer patients. The disadvantages of the two previous methods used for evaluating axillary node metastasis, i.e., axillary lymph node dissection and sentinel lymph node biopsy, have directed researchers to investigate new techniques for this purpose. The aim of the current study was to evaluate the clinical usefulness of axillary ultrasonography in detecting axillary metastasis. Methods: This study was conducted during a 12-month period. The breast cancer cases included in this study were all clinically diagnosed as stages I and II, with no prior treatment to the axillary region by surgery and/or chemo-radiotherapy. Excluded from the study group were patients with palpable axillary lymph nodes, those who had major organ failure or concomitant malignancy. All included patients with non-palpable axillary lymph nodes underwent axillary ultrasound examination. An ultrasound- guided core needle biopsy was performed on patients with suspected metastasis. Results: There were 125 female patients with a mean age of 49.6 years included in this study. From these, 16 (12.8% cases had positive axillary sonographic findings. Pathologic evaluation of tissue specimens (taken by ultrasound-guided core needle biopsy in 10 (62.5% out of 16 patients were positive, and in the patient group of 6 (37.5% cases, studies were negative. Axillary ultrasonography had a sensitivity of 35.7%, specificity of 93.8%, positive predictive value of 62.5%, and negative predictive value of 83.5%. Conclusion: The axillary ultrasonogram is a reliable technique in the determination of axillary nodal metastatic involvement in breast cancer patients. By use of this method a significant amount of complications and costs related to the previous techniques can be avoided.

  16. Detection of oral squamous cell carcinoma metastasis with cathepsin D: An immunohistochemical approach

    Directory of Open Access Journals (Sweden)

    Seema Kapoor

    2014-01-01

    Full Text Available Background: The lysosomal protease cathepsin D (CD has been associated with tumor progression in malignant tumors including oral squamous cell carcinoma (OSCC. The purpose of this study was to find out any association between the CD and lymph node metastasis and to study the correlation of CD with various clinicopathological parameters to aid in assessment of its role as a prognostic indicator. Materials and Methods: Immunohistochemical staining was performed on 20 OSCC samples with polyclonal antibody against CD. Positive results indicative of the presence of CD were further analyzed to determine any correlation between the CD and other clinicopathological parameters. Pearson Chi-square analyses, Spearsman correlation coefficient, Mann-Whitney test, Kruskal Wallis test and student t test were used for statistical analysis (P < 0.05. Results: Patients with lymph node metastasis showed statistically significant increase in CD expression (P < 0.01. Increasing tumor size seemed to correlate with increased CD expression (P < 0.05. Conclusion: Based on its association with other clinicopathological variables, CD expression can be used for the assessment of patient survival in cases of OSCC.

  17. Application of a conversion factor to estimate the adenoma detection rate from the polyp detection rate.

    LENUS (Irish Health Repository)

    Francis, Dawn L

    2011-03-01

    The adenoma detection rate (ADR) is a quality benchmark for colonoscopy. Many practices find it difficult to determine the ADR because it requires a combination of endoscopic and histologic findings. It may be possible to apply a conversion factor to estimate the ADR from the polyp detection rate (PDR).

  18. Prognostic value of incidental hypervascular micronodules detected on cone-beam computed tomography angiography of patients with liver metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Odisio, Bruno C.; Mahvash, Armeen; Gupta, Sanjay; Tam, Alda L.; Murthy, Ravi [The University of Texas MD Anderson Cancer Center, Department of Interventional Radiology, Division of Diagnostic Imaging, Houston, TX (United States); Cox, Veronica L.; Faria, Silvana C. [The University of Texas MD Anderson Cancer Center, Diagnostic Radiology, Houston, TX (United States); Yamashita, Suguru; Vauthey, Jean-Nicolas [The University of Texas MD Anderson Cancer Center, Surgical Oncology, Houston, TX (United States); Shi, Xiao [Baylor College of Medicine, Department of Diagnostic Radiology, Houston, TX (United States); Ensor, Joe [Biostatistics of the Houston Methodist Cancer Center, Houston, TX (United States); Jones, Aaron K. [The University of Texas MD Anderson Cancer Center, Imaging Physics, Houston, TX (United States)

    2017-11-15

    To determine the clinical relevance of incidentally-found hypervascular micronodules (IHM) on cone-beam computed tomography angiography (CBCTA) in patients with liver metastasis undergoing transarterial (chemo)embolization (TACE/TAE). This was a HIPAA-compliant institutional review board-approved single-institution retrospective review of 95 non-cirrhotic patients (52 men; mean age, 60 years) who underwent CBCTA prior to (chemo)embolic delivery. IHM were defined by the presence of innumerable subcentimetre hepatic parenchymal hypevascular foci not detected on pre-TACE/TAE contrast-enhanced cross-sectional imaging. Multivariate analysis was performed to compare time to tumour progression (TTP) between patients with and without IHM. IHM were present in 21 (22%) patients. Patients with IHM had a significantly shorter intrahepatic TTP determined by a higher frequency of developing new liver metastasis (hazard ratio [HR]: 1.99; 95% confidence interval [CI] 1.08-3.67, P= 0.02). Patients with IHM trended towards a shorter TTP of the tumour(s) treated with TACE/TAE (HR: 1.72; 95% CI: 0.98-3.01, P= 0.056). Extrahepatic TTP was not significantly different between the two cohorts (P= 0.27). Patients with IHM on CBCTA have worse prognosis due to a significantly higher risk of developing new hepatic tumours. Further work is needed to elucidate its underlying mechanisms of pathogenesis. (orig.)

  19. Leak rate measurements and detection systems

    International Nuclear Information System (INIS)

    Kupperman, D.; Shack, W.J.; Claytor, T.

    1983-10-01

    A research program is under way to evaluate and develop improve leak detection systems. The primary focus of the work has been on acoustic emission detection of leaks. Leaks from artificial flaws, laboratory-generated IGSCCs and thermal fatigue cracks, and field-induced intergranular stress corrosion cracks (IGSCCs) from reactor piping have been examined. The effects of pressure, temperature, and leak rate and geometry on the acoustic signature are under study. The use of cross-correlation techniques for leak location and pattern recognition and autocorrelation for source discrimination is also being considered

  20. PET-CT detection rate of primary breast cancer lesions. Correlation with the clinicopathological factors

    International Nuclear Information System (INIS)

    Ogawa, Tomoko; Tozaki, Mitsuhiro; Fukuma, Eisuke

    2008-01-01

    One hundred and forty lesions of primary breast cancer underwent positron emission tomography (PET)-CT between June 2006 and May 2007. The PET-CT detection rate of primary breast cancer lesions was 72.1%. The detection rate was 52.1% for invasive cancer ≤20 mm, 92.8% for invasive breast cancers >20 mm, and these results were significant. In the present study, no significant relationship was observed between tumor types, however, invasive lobular carcinoma showed a lower detection rate, 58.3%. The PET-CT results were not significantly affected by either estrogen and progesterone receptors or distant metastasis. A significant correlation regarding the detection rate of PET-CT was found with HER2 status, tumor grade, and axillary lymph node status. The detection rate was 100% for invasive cancer ≤20 mm when the interval between prior diagnostic Mammotome biopsies and PET-CT was less than 3 weeks, 18.8% for invasive cancer ≤20 mm when the interval was more than 3 weeks, and these results were significant. Mammotome biopsies may therefore affect the detection rate of PET-CT. Invasive cancers ≤20 mm showed a low detection rate, therefore, it is considered to be insufficient to use PET-CT for the detection of early breast cancer. (author)

  1. The usefulness of early whole body bone scintigraphy in the detection of bone metastasis from prostatic cancer

    International Nuclear Information System (INIS)

    Otsuka, Nobuaki; Fukunaga, Masao; Furukawa, Yohji; Tanaka, Hiroyoshi

    1994-01-01

    Early whole body bone scintigraphy was performed on 25 patients with prostatic cancer (15 cases with bone metastases and 10 cases without bone metastasis) to obtain anterior and posterior whole body images five minutes after administration of 99m Tc-hydroxymethylene diphosphonate(HMDP). The results were compared with the findings of routine bone scintigraphy after three hours, and the usefulness of the above method for the diagnosis of bone metastasis from prostatic cancer was evaluated. In cases in which increased activity was found in the upper and lower lumbar vertebrae by routine bone scintigraphy but no abnormality was seen by early whole body bone scintigraphy, senile degenerative bone changes such as spondylosis deformance were observed by bone radiography. In cases with multiple bone metastases, abnormal multiple accumulations were found by both early whole body bone scintigraphy and routine bone scintigraphy. In addition, in cases showing super bone scan, high accumulation in the skeletal system had already been detected by early whole body bone scintigraphy. When the courses before and after treatment in nine cases of multiple bone metastases were passaged from the results of early whole body bone scintigraphy and from changes in tumor markers (prostatic specific antigen, γ-semino protein and prostatic acid phosphatase), increased activity and the appearance of new hot spots as well as an increase in tumor markers were detected by early whole body scintigraphy in three of the four advanced cases, whereas decreased accumulations and a decrease in and normalization of tumor markers were observed in five improved cases. (author)

  2. The usefulness of early whole body bone scintigraphy in the detection of bone metastasis from prostatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Nobuaki; Fukunaga, Masao; Furukawa, Yohji; Tanaka, Hiroyoshi [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    1994-06-01

    Early whole body bone scintigraphy was performed on 25 patients with prostatic cancer (15 cases with bone metastases and 10 cases without bone metastasis) to obtain anterior and posterior whole body images five minutes after administration of [sup 99m]Tc-hydroxymethylene diphosphonate(HMDP). The results were compared with the findings of routine bone scintigraphy after three hours, and the usefulness of the above method for the diagnosis of bone metastasis from prostatic cancer was evaluated. In cases in which increased activity was found in the upper and lower lumbar vertebrae by routine bone scintigraphy but no abnormality was seen by early whole body bone scintigraphy, senile degenerative bone changes such as spondylosis deformance were observed by bone radiography. In cases with multiple bone metastases, abnormal multiple accumulations were found by both early whole body bone scintigraphy and routine bone scintigraphy. In addition, in cases showing super bone scan, high accumulation in the skeletal system had already been detected by early whole body bone scintigraphy. When the courses before and after treatment in nine cases of multiple bone metastases were passaged from the results of early whole body bone scintigraphy and from changes in tumor markers (prostatic specific antigen, [gamma]-semino protein and prostatic acid phosphatase), increased activity and the appearance of new hot spots as well as an increase in tumor markers were detected by early whole body scintigraphy in three of the four advanced cases, whereas decreased accumulations and a decrease in and normalization of tumor markers were observed in five improved cases. (author).

  3. Rate of Appendiceal Metastasis with Non-Serous Epithelial Ovarian Cancer in Manitoba.

    Science.gov (United States)

    Altman, Alon D; Lefas, Georgia; Power, Laura; Lambert, Pascal; Lotocki, Robert; Dean, Erin; Nachtigal, Mark W

    2018-02-01

    This study sought to evaluate the rate of appendiceal involvement in non-serous mucinous and endometrioid-associated epithelial ovarian cancers. The Manitoba Cancer Registry and CancerCare database were used to find all women with non-serous epithelial ovarian, fallopian tube, or primary peritoneal cancer between 1995 and 2011. All patients with an appendectomy were then identified, and their final pathology findings were reviewed. Women who did not receive treatment or lacked follow-up were excluded. We identified 338 patients from 1995-2011 with no prior appendectomy. Of these, 16.6% received an appendectomy, and 22.8% were clinically evaluated. Most cases within this cohort were mucinous (62%) and stage 1 (63%). Four appendiceal metastases were identified (7.2%), and one half appeared clinically normal at the time of surgery (3.6%). Within the mucinous histologic type, 32.7% of patients received an appendectomy, with a metastatic rate of 5.7%. Of the 127 endometrioid cases, only 10 patients received an appendectomy, and 2 were found to have metastases. No metastases were found in the 85 patients in the clear cell cohort, only 5 of whom received an appendectomy. Routine appendectomy or clinical assessment of the appendix is valuable for all non-serous ovarian cancers. The rate of involvement for endometriosis-associated ovarian cancers may be significantly higher than expected, and further studies need to be conducted. Copyright © 2018 Society of Obstetricians and Gynaecologists of Canada. Published by Elsevier Inc. All rights reserved.

  4. Whole lung computed tomography for detection of pulmonary metastasis of osteosarcoma confirmed at thoracotomy

    International Nuclear Information System (INIS)

    Ishida, Itsuro; Fukuma, Seigo; Sawada, Kinya; Seki, Yasuo; Tanaka, Fumitaka

    1980-01-01

    Whole lung computed tomography (CT) was performed in patients with osteosarcoma of bone to evaluate its diagnostic efficacy in comparison to that in conventional chest radiography and in whole lung tomography to detect metastatic nodules in the lung. In 11 of the 12 patients with osteosarcoma, CT detected pulmonary nodules and in 6 of the 11 patients pulmonary nodules were detected by CT, conventional chest radiography and whole lung tomography, respectively, and 22 pulmonary nodules were resected at thoracotomy and proved to be metastatic lesions. Nineteen nodules of the 22 nodules resected were detected by CT and nine of the 22 nodules were discovered only by CT, while only 10 of 22 nodules were recognized by the conventional chest radiography and the whole lung tomography. Two pulmonary nodules, measuring 1 mm and 2 mm in diameter, respectively, were not detected by any of these three methods. In three nodules that showed to be false positive in CT in the two patients, two nodules were histologically suture granulomas induced by the previous operation, and a deformed protuberance of the chest wall was erroneously interpreted to be a subpleural and intrapulmonary nodule in the remaining. We conclude that CT is the most efficient method to detect pulmonary nodules in the patients with osteosarcoma, but that the minimal size of the detectable nodule by CT is 3 mm in diameter. But a smaller nodule having a tendency to ossify can be detected by CT. (author)

  5. Application of detecting cerebrospinal fluid circulating tumor cells in the diagnosis of meningeal metastasis of non-small cell lung cancer

    OpenAIRE

    Rong JIANG; Chun-hua MA; Zi-long ZHU; Jin-duo LI; Bin WANG; Li-wei SUN; Yuan LÜ

    2014-01-01

    Objective To observe a new technology for the detection and enumeration of cerebrospinal fluid (CSF) circulating tumor cells (CTCs) in the diagnosis of non-small cell lung cancer (NSCLC) with meningeal metastasis (MM).  Methods Five cases of NSCLC with MM that were diagnosed by CSF cytology were selected, and 20 ml CSF samples were obtained by lumbar puncture for every patient. The tumor marker immunostaining-fluorescence in situ hybridization (TM-iFISH) technology was adapted to detect...

  6. Detection of distant metastasis and prognostic prediction of recurrent salivary gland carcinomas using 18 F-FDG PET/CT.

    Science.gov (United States)

    Lee, S H; Roh, J-L; Kim, J S; Lee, J H; Choi, S-H; Nam, S Y; Kim, S Y

    2018-04-24

    To compare the diagnostic accuracy of 18 F-FDG PET/CT and conventional contrast-enhanced CT for the re-staging of recurrent salivary gland carcinoma (SGC). This study included 58 consecutive patients who underwent recurrent SGCs after definitive treatment. The recurrences were evaluated by 18 F-FDG PET/CT and contrast-enhanced CT of the neck and chest. McNemar's test was used to compare the diagnostic accuracy of 18 F-FDG PET/CT with standard neck and chest CT imaging, and a Cox proportional hazards model was used to assess the prognostic value of PET/CT. Of 58 patients with recurrent SGCs, 17 (29%) had a local recurrence, 17 (29%) had a regional recurrence, and 38 (66%) had a distant metastasis, with these classifications showing overlap. The sensitivity and accuracy of 18 F-FDG PET/CT for the detection of distant metastases were significantly higher than those of CT (P 0.1). The 18 F-FDG PET/CT-positive findings at distant sites were predictors of poor progression-free and overall survival outcome (all P PET/CT is a more effective method than CT for detecting distant site recurrences of SGC. This may lead to prognostic prediction for recurrent SGCs. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  7. Drowsiness detection using heart rate variability.

    Science.gov (United States)

    Vicente, José; Laguna, Pablo; Bartra, Ariadna; Bailón, Raquel

    2016-06-01

    It is estimated that 10-30 % of road fatalities are related to drowsy driving. Driver's drowsiness detection based on biological and vehicle signals is being studied in preventive car safety. Autonomous nervous system activity, which can be measured noninvasively from the heart rate variability (HRV) signal obtained from surface electrocardiogram, presents alterations during stress, extreme fatigue and drowsiness episodes. We hypothesized that these alterations manifest on HRV and thus could be used to detect driver's drowsiness. We analyzed three driving databases in which drivers presented different sleep-deprivation levels, and in which each driving minute was annotated as drowsy or awake. We developed two different drowsiness detectors based on HRV. While the drowsiness episodes detector assessed each minute of driving as "awake" or "drowsy" with seven HRV derived features (positive predictive value 0.96, sensitivity 0.59, specificity 0.98 on 3475 min of driving), the sleep-deprivation detector discerned if a driver was suitable for driving or not, at driving onset, as function of his sleep-deprivation state. Sleep-deprivation state was estimated from the first three minutes of driving using only one HRV feature (positive predictive value 0.80, sensitivity 0.62, specificity 0.88 on 30 drivers). Incorporating drowsiness assessment based on HRV signal may add significant improvements to existing car safety systems.

  8. Comparison of three different methods for the detection of circulating tumor cells in mice with lung metastasis.

    Science.gov (United States)

    Xu, Weifeng; Wu, Bing; Fu, Lengxi; Chen, Junying; Wang, Zeng; Huang, Fei; Chen, Jinrong; Zhang, Mei; Zhang, Zhenhuan; Lin, Jingan; Lan, Ruilong; Chen, Ruiqing; Chen, Wei; Chen, Long; Hong, Jinsheng; Zhang, Weijian; Ding, Yuxiong; Okunieff, Paul; Lin, Jianhua; Zhang, Lurong

    2017-06-01

    Circulating tumor cells (CTCs) represent the key step of cancer cell dissemination. The alteration of CTCs correlates with the treatment outcome and prognosis. To enrich and identify CTCs from billions of blood cells renders a very challenging task, which triggers development of several methods, including lysis of RBC plus negative or positive enrichment using antibodies, and filter membrane or spiral microfluidics to capture CTCs. To compare the advantages of different enrichment methods for CTCs, we utilized the 4T1 breast cancer cells transfected with both green fluorescent protein (GFP) and luciferase to trace CTCs in the experimental lung metastasis model. Three methods were used to detect CTCs at the same time: bioluminescence assay, smearing method, and membrane filter method. The in vivo alive mouse imaging was used to dynamically monitor the growth of lung metastases. The sensitivity and accuracy of three detection methods were compared side-by-side. Our results showed that 1) the sensitivity of bioluminescence assay was the highest, but there was no information of CTC morphology; 2) the smearing method and membrane filter method could observe the detail of CTC morphology, such as in single or in cluster, while their sensitivity was lower than bioluminescence assay; 3) A dynamic observation at a 7-day intervals, the lung metastatic cancer grew at a log speed, while CTCs were increased at a low speed. This might be due to the activated immune cells eliminating the CTCs at a speed much faster than CTCs were generated. This comparison of three CTC detection methods in mouse model suggests that bioluminescence assay could be used in quantitative study of the effect of certain agent on the suppression of CTCs, while GFP-based morphological assays could be used to study the dissemination mechanism of CTCs. The combination of both bioluminescence assay and GFP-based assay would generate more information for quantity and quality of CTCs.

  9. Bone position emission tomography with or without CT Is more accurate than bone scan for detection of bone metastasis

    International Nuclear Information System (INIS)

    Lee, Soo Jin; Lee, Wom Woo; Kim, Sang Eun

    2013-01-01

    Na1 8F bone positron emission tomography (bone PET) is a new imaging modality which is useful for the evaluation of bone diseases. Here, we compared the diagnostic accuracies between bone PET and bone scan for the detection of bone metastasis (BM). Sixteen cancer patients (M:F = 10:6, mean age = 60 ± 12 years) who underwent both bone PET and bone scan were analyzed. Bone PET was conducted 30 minutes after the injection of 370 MBq Na1 8F , and a bone scan was performed 3 hours after the injection of 1295 MBq 9 9mT c-hydroxymethylene diphosphonate. In the patient-based analysis (8 patients with BM and 8 without BM), the sensitivities of bone PET (100% 8/8) and bone scan (87.5% = 7/8) were not significantly different (p > 0.05), whereas the specificity of bone PET (87.5% = 7/8) was significantly greater than that of the bone scan (25% = 2/8) (p 8F bone PET is more accurate than bone scan for BM evaluation.

  10. Value of whole body 123I scan for detection of metastasis in patients with well-differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Takahashi, Naoya; Odano, Ikuo; Sugita, Tadashi; Sato, Yoko; Sakai, Kunio

    1995-01-01

    To evaluate the utility of 123 I whole body scan for detection of metastasis in patients with well-differentiated thyroid carcinoma, post-therapy whole body 131 I images in 55 cases were compared with pre-therapy 123 I images using diagnostic dose (74 MBq). The post-therapy studies were performed 7 days after administration of therapeutic doses (3.33-7.77 GBq) of 131 I. The pre-therapy scans showed 30 lesions (71.4%) of 42 lesions which were shown by 131 I post-therapy scans. The diagnostic accuracy of 123 I whole body scans was considered to be nearly the same as the images obtained by 131 I using diagnostic dose. 123 I has short-life and an optimum gamma ray energy for scintigraphy. It makes radiation dose to patients lower than that of 131 I. Therefore, we recommend pre-therapy 131 I image using diagnostic dose is replaced by 123 I image. (author)

  11. Tumor Budding Detection by Immunohistochemical Staining is Not Superior to Hematoxylin and Eosin Staining for Predicting Lymph Node Metastasis in pT1 Colorectal Cancer.

    Science.gov (United States)

    Okamura, Takuma; Shimada, Yoshifumi; Nogami, Hitoshi; Kameyama, Hitoshi; Kobayashi, Takashi; Kosugi, Shin-ichi; Wakai, Toshifumi; Ajioka, Yoichi

    2016-05-01

    Tumor budding is recognized as an important risk factor for lymph node metastasis in pT1 colorectal cancer. Immunohistochemical staining for cytokeratin has the potential to improve the objective diagnosis of tumor budding over detection based on hematoxylin and eosin staining. However, it remains unclear whether tumor budding detected by immunohistochemical staining is a significant predictor of lymph node metastasis in pT1 colorectal cancer. The purpose of this study was to clarify the clinical significance of tumor budding detected by immunohistochemical staining in comparison with that detected by hematoxylin and eosin staining. This was a retrospective study. The study was conducted at Niigata University Medical & Dental Hospital. We enrolled 265 patients with pT1 colorectal cancer who underwent surgery with lymph node dissection. Tumor budding was evaluated by both hematoxylin and eosin and immunohistochemical staining with the use of CAM5.2 antibody. Receiver operating characteristic curve analyses were conducted to determine the optimal cutoff values for tumor budding detected by hematoxylin and eosin and CAM5.2 staining. Univariate and multivariate analyses were performed to identify the significant factors for predicting lymph node metastasis. Receiver operating characteristic curve analyses revealed that the cutoff values for tumor budding detected by hematoxylin and eosin and CAM5.2 staining for predicting lymph node metastases were 5 and 8. On multivariate analysis, histopathological differentiation (OR, 6.21; 95% CI, 1.16-33.33; p = 0.03) and tumor budding detected by hematoxylin and eosin staining (OR, 4.91; 95% CI, 1.64-14.66; p = 0.004) were significant predictors for lymph node metastasis; however, tumor budding detected by CAM5.2 staining was not a significant predictor. This study was limited by potential selection bias because surgically resected specimens were collected instead of endoscopically resected specimens. Tumor budding detected by

  12. Diagnostic performance of fluorodeoxyglucose-positron emission tomography/computed tomography of breast cancer in detecting axillary lymph node metastasis. Comparison with ultrasonography and contrast-enhanced CT

    International Nuclear Information System (INIS)

    Monzawa, Shuichi; Adachi, Shuji; Suzuki, Kayo; Hirokaga, Koichi; Takao, Shintaro; Sakuma, Toshiko; Hanioka, Keisuke

    2009-01-01

    The purpose of this retrospective study was to evaluate the diagnostic performance of positron emission tomography/computed tomography (PET/CT) with fluorine-18-labeled 2-fluoro-2-deoxy-D-glucose (FDG) in comparison with that of ultrasonography and contrast-enhanced computed tomography (CT) in detecting axillary lymph node metastasis in patients with breast cancer. Fifty patients with invasive breast cancer were recruited. They had received no neoadjuvant chemotherapy and underwent PET/CT, ultrasonography and contrast-enhanced CT before mastectomy. The clinical stage was I in 34 patients, II in 15 patients, and III in one patient. The images of these modalities were interpreted in usual practice before surgery and the diagnostic reports were reviewed for analysis. Sensitivity, specificity, positive predictive value, and negative predictive value of each modality were obtained taking histopathological results of axillary lymph node dissection or sentinel lymph node biopsy as the reference standard. Axillary lymph node metastasis was confirmed in 15 of 50 patients by histopathological studies. PET/CT identified lymph node metastasis in three of these 15 patients. The overall sensitivity and specificity, positive predictive value, and negative predictive value of PET/CT in the diagnosis of axillary lymph node metastasis were 20, 97, 75, and 74%, and those of ultrasonography were 33, 94, 71, and 77% and those of contrast-enhanced CT were 27, 97, 80, and 76%, respectively. PET/CT showed poor sensitivity and high specificity in the detection of axillary lymph node metastasis of breast cancer. Diagnostic performance of PET/CT was not superior to that of ultrasonography and contrast-enhanced CT. (author)

  13. Relative value of thallium-201 and iodine-131 scans in the detection of recurrence or distant metastasis of well differentiated thyroid carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jen-Der; Weng Hsiao-Fen; Lu Wen-Tsoung [Division of Endocrinology and Metabolism, Chang Gung Memorial Hospital (Taiwan, Province of China); Kao Pan-Fu; Huang Miau-Ju [Department of Nuclear Medicine, Chang Gung Memorial Hospital, Taiwan (Taiwan, Province of China)

    1998-07-01

    Radioactive iodine ({sup 131}I) has been found to be more sensitive and more specific than thallium-201 for the detection of distant metastases and thyroid remnants in the neck in cases of well-differentiated thyroid carcinoma. {sup 201}Tl has been deemed particularly useful in localizing metastases or recurrence in patients with a negative {sup 131}I scan and abnormal levels of serum thyroglobulin (Tg). This study aimed to: (1) determine the value of {sup 201}Tl imaging in localizing metastases or recurrence in patients with well-differentiated thyroid carcinoma, and (2) evaluate the false-positive and false-negative results of {sup 131}I and {sup 201}Tl scintigraphy. Sixty-two thyroid remnant ablated patients who underwent simultaneous postoperative {sup 201}Tl and {sup 131}I scans and and serum Tg determinations were evaluated. Fifty patients had papillary thyroid carcinomas and 12 had follicular thyroid carcinomas. {sup 201}Tl imaging was performed before the {sup 131}I studies. Of the 62 patients who underwent {sup 201}Tl imaging studies, 24 were found to have positive results, with local recurrence or distant metastases. Patients with positive results in the {sup 201}Tl imaging studies tended to be older, were mor often male, had higher Tg levels and had a higher recurrence rate. Of these 24 patients, ten had negative diagnostic or therapeutic {sup 131}I scans. Concurrently, serum Tg levels were less than 5 ng/ml in five of these ten patients. Three patients were deemed false positive by {sup 201}Tl scans; one had a parotid tumour, one a periodontal abscess and one lung metastasis. Among the 38 patients with negative {sup 201}Tl scans, 11 had positive findings on {sup 131}I scans. Three had distant metastases: two with lung metastases and one with bone metastases. Patients with false-positive results on {sup 131}I scans included those with biliary tract stones, ovarian cysts, and breast secretion. Of the 27 patients with negative {sup 201}Tl and {sup 131}I

  14. Relative value of thallium-201 and iodine-131 scans in the detection of recurrence or distant metastasis of well differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Lin Jen-Der; Weng Hsiao-Fen; Lu Wen-Tsoung; Kao Pan-Fu; Huang Miau-Ju

    1998-01-01

    Radioactive iodine ( 131 I) has been found to be more sensitive and more specific than thallium-201 for the detection of distant metastases and thyroid remnants in the neck in cases of well-differentiated thyroid carcinoma. 201 Tl has been deemed particularly useful in localizing metastases or recurrence in patients with a negative 131 I scan and abnormal levels of serum thyroglobulin (Tg). This study aimed to: (1) determine the value of 201 Tl imaging in localizing metastases or recurrence in patients with well-differentiated thyroid carcinoma, and (2) evaluate the false-positive and false-negative results of 131 I and 201 Tl scintigraphy. Sixty-two thyroid remnant ablated patients who underwent simultaneous postoperative 201 Tl and 131 I scans and and serum Tg determinations were evaluated. Fifty patients had papillary thyroid carcinomas and 12 had follicular thyroid carcinomas. 201 Tl imaging was performed before the 131 I studies. Of the 62 patients who underwent 201 Tl imaging studies, 24 were found to have positive results, with local recurrence or distant metastases. Patients with positive results in the 201 Tl imaging studies tended to be older, were mor often male, had higher Tg levels and had a higher recurrence rate. Of these 24 patients, ten had negative diagnostic or therapeutic 131 I scans. Concurrently, serum Tg levels were less than 5 ng/ml in five of these ten patients. Three patients were deemed false positive by 201 Tl scans; one had a parotid tumour, one a periodontal abscess and one lung metastasis. Among the 38 patients with negative 201 Tl scans, 11 had positive findings on 131 I scans. Three had distant metastases: two with lung metastases and one with bone metastases. Patients with false-positive results on 131 I scans included those with biliary tract stones, ovarian cysts, and breast secretion. Of the 27 patients with negative 201 Tl and 131 I scans, 15 had elevated serum Tg levels. Among these, local recurrence followed by lung

  15. Detection of brain metastasis. Comparison of Turbo-FLAIR imaging, T2-weighted imaging and double-dose gadolinium-enhanced MR imaging

    International Nuclear Information System (INIS)

    Okubo, Toshiyuki; Hayashi, Naoto; Shirouzu, Ichiro; Abe, Osamu; Ohtomo, Kuni; Sasaki, Yasuhito; Aoki, Shigeki; Wada, Akihiko

    1998-01-01

    The purpose of this study was to compare Turbo-FLAIR imaging, T 2 -weighted imaging, and double-dose gadolinium-enhanced MR imaging in the detection of brain metastasis. Using the three sequences, 20 consecutive patients with brain metastases were prospectively studied with a 1.5-Tesla system. Three independent, blinded readers assessed the images for the presence, size, number, and location of metastatic lesions. In the detection of large lesions (>0.5 cm), Turbo-FLAIR imaging (38/48, 79%) was not significantly different from gadolinium-enhanced imaging (42/48, 88%) (p=0.273). T 2 -weighted imaging (31/48, 65%), however, was inferior to gadolinium-enhanced imaging (p<0.05). There was no difference between Turbo-FLAIR imaging and gadolinium-enhanced imaging in the accuracy of detecting solitary brain metastasis (4/4, 100%). In conclusion, Turbo-FLAIR imaging is a useful, noninvasive screening modality for brain metastasis. Its use may lead to cost savings in the diagnosis of brain metastases and may impact positively the cost-effectiveness of treatment. (author)

  16. Detection of skeletal muscle metastasis: torso FDG PET-CT versus contrast-enhanced chest or abdomen CT.

    Science.gov (United States)

    So, Young; Yi, Jeong Geun; Song, Inyoung; Lee, Won Woo; Chung, Hyun Woo; Park, Jeong Hee; Moon, Sung Gyu

    2015-07-01

    Skeletal muscle metastasis (SMM) in cancer patients has not been sufficiently evaluated regarding prevalence and proper method of detection. To determine the prevalence of SMM and compare the diagnostic competencies for SMM of torso F-18 fluorodeoxyglucose (FDG) positron emission tomography-computed tomography (PET-CT) and contrast-enhanced chest or abdomen CT. We investigated 18,225 PET-CT studies of 6359 cancer patients performed from 2005 to 2012. The PET-CT studies describing potential SMM were retrieved and the corresponding medical records were reviewed. The gold standard for SMM was histopathologically-proven SMM or imaging study-based disease progression. The detectability of SMM was compared between PET-CT and contrast-enhanced CT. Twenty-six patients had 84 SMM lesions, representing a SMM prevalence of 0.41%. Lung cancer was the most common SMM-associated malignancy (54%) and the gluteal/pelvic girdle muscle was the most frequently involved SMM site (37%). All 84 SMM lesions were visualized on PET-CT (100%). Of these PET-CT positive 84 SMM lesions, 51 lesions were in the CT field of view (FOV) (61%), whereas 33 lesions were out of the CT FOV (39%). Among these 51 lesions, 17 lesions showed rim-enhancing nodules/masses (33%), eight lesions showed homogeneously enhancing nodules (16%), three lesions showed heterogeneously enhancing nodules (6%), and 23 SMM lesions (45%) were non-diagnostic by CT. All 51 SMM lesions within CT FOV were detected on PET-CT (100%), whereas only 28 were visualized on CT (54.9%), resulting in a significant difference (P SMM was revealed by PET-CT. The prevalence of SMM was as low as 0.41% in the current large cohort of cancer patients. Torso PET-CT was a more competent modality than contrast-enhanced CT in the detection of SMM. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  17. Hypophyseal metastasis

    International Nuclear Information System (INIS)

    Yanes Quesada, Miguel Angel; Yanes Quesada, Marelys; Lopez Arbolay, Omar; Lima Perez, Mayte; Hernandez Yero, Arturo

    2009-01-01

    Metastatic tumors of hypophyseal gland are infrequent. Most are silent lesions discovered accidentally in necropsy. Appearance of symptomatic metastasis is however, exceptional. We describe here clinical and radiological findings in a female patient aged 69, presenting with a non-differential carcinoma of lung, diagnosed two years a half ago, starting with headache and visual disorders without hypopituitarism and insipidus diabetes. We made a nuclear magnetic resonance and diagnosis was a hypophyseal lesion operated on by trans-esphenoidal route, and Pathological Anatomy Service reports a metastasis of lung carcinoma. (Author)

  18. Intratumoral and peritumoral lymphovascular invasion detected by D2-40 immunohistochemistry correlates with metastasis in primary cutaneous Merkel cell carcinoma.

    Science.gov (United States)

    Al-Rohil, Rami N; Milton, Denái R; Nagarajan, Priyadharsini; Curry, Jonathan L; Feldmeyer, Laurence; Torres-Cabala, Carlos A; Ivan, Doina; Prieto, Victor G; Tetzlaff, Michael T; Aung, Phyu P

    2018-07-01

    Primary cutaneous Merkel cell carcinoma (MCC) is an aggressive neuroendocrine malignancy in which lymphovascular invasion (LVI) correlates with more aggressive phenotype. The prognostic significance of LVI detected by D2-40 immunohistochemistry (IHC) in MCC remains controversial. We aimed to determine how LVI detected by D2-40 IHC compares with LVI detected by hematoxylin and eosin (H&E) staining in predicting MCC metastasis. Clinical and histopathologic features of MCCs diagnosed and treated in 2002 to 2015 were assembled and included 58 MCC tumors from 58 patients. H&E-stained tissue sections and D2-40 IHC studies were reviewed. When LVI was present, the location (peritumoral or intratumoral) and the size of the largest invaded vessel were recorded. LVI findings by H&E staining and D2-40 IHC were compared with each other and with histologic features and clinical outcomes. H&E staining showed LVI in 37 of 58 cases; D2-40 IHC confirmed LVI in 30 of these cases but failed to confirm LVI in 7. D2-40 IHC also detected 14 cases of LVI not identified on H&E staining. Histologically, D2-40-detected LVI was associated with infiltrative growth pattern and nonbrisk lymphoid infiltrate (P = .005 and P = .055, respectively). There was a statistically significant difference between the frequency of detection of peritumoral LVI by H&E in comparison to D2-40 IHC (P = .0009). MCCs in which D2-40 IHC-detected both intratumoral and peritumoral LVI were typically larger than MCCs without (mean, 24.5 mm versus 17.3 mm; P = .03) and more frequently metastasized (87% versus 51%; P = .03). D2-40 IHC detection of both intratumoral and peritumoral LVI is associated with metastasis. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Clinical value of 18F-FDG and 18F-FLT PET /CT for the detection of primary and regional lymph node metastasis of gastric cancer

    Institute of Scientific and Technical Information of China (English)

    杨洋

    2014-01-01

    Objective To evaluate the value of18F-FDG and18F-FLT PET/CT for the detection of primary and regional lymph node metastasis of gastric cancer.Methods Thirty-seven patients with gastric cancer underwent preoperative18F-FLT and18F-FDG PET/CT within one week from March 2011 to April 2013.Postoperative histopathology confirmation was obtained in all patients.The PET/CT images were assessed visually and semi-quantitatively.Two-sample t andχ2tests were analyzed using SPSS overall diagnostic

  20. Detection of lymph node metastasis in patients with nodal prostate cancer relapse using (18)F/(11)C-choline positron emission tomography/computerized tomography.

    Science.gov (United States)

    Jilg, Cordula A; Schultze-Seemann, Wolfgang; Drendel, Vanessa; Vach, Werner; Wieser, Gesche; Krauss, Tobias; Jandausch, Anett; Hölz, Stefanie; Henne, Karl; Reske, Sven N; Grosu, Anca-L; Weber, Wolfgang A; Rischke, H Christian

    2014-07-01

    We evaluated the diagnostic accuracy of choline positron emission tomography/computerized tomography for nodal relapse of prostate cancer according to topographical site and tumor infiltration size in lymph nodes. A total of 72 patients with nodal prostate cancer relapse after primary therapy underwent pelvic and/or retroperitoneal salvage lymph node dissection. Salvage was done after whole body positron emission tomography/computerized tomography with (11)C-choline or (18)F-fluoroethylcholine showed positron emission tomography positive lymph nodes but no other detectable metastasis. Diagnostic accuracy was evaluated in 160 dissected lymph node regions (pelvic left/right and retroperitoneal), 498 subregions (common, external and internal iliac, obturator, presacral, aortic bifurcation, aortal, vena caval and interaortocaval) and 2,122 lymph nodes. Lymph node metastasis was present in 32% of resected lymph nodes (681 of 2,122), resulting in 238 positive subregions and 111 positive regions. Positron emission tomography/computerized tomography was positive for 110 regions and 209 subregions. Sensitivity, specificity, positive and negative predictive values, and accuracy were 91.9%, 83.7%, 92.7%, 82.0% and 89.4% (region based), 80.7%, 93.5%, 91.9%, 84.1% and 87.3% (subregion based), and 57.0%, 98.4%, 94.5%, 82.6% and 84.9% (lesion based), respectively. Of 393 positive lymph node metastases detected by this method 278 (70.7%) were in lymph nodes with a less than 10 mm short axis diameter. Imaging sensitivity was 13.3%, 57.4% and 82.8% for a tumor infiltration depth of 2 or greater to less than 3 mm, 5 or greater to less than 6 mm and 10 or greater to less than 11 mm, respectively. Lymph node metastasis site and the radiotracer ((11)C-choline/(18)F-fluoroethylcholine) had no substantial impact on diagnostic accuracy. Choline positron emission tomography/computerized tomography detects affected lymph node regions (pelvic left/right and retroperitoneal) in patients with

  1. F-18 Sodium Fluoride Positron Emission Tomography/Computed Tomography for Detection of Thyroid Cancer Bone Metastasis Compared with Bone Scintigraphy.

    Science.gov (United States)

    Lee, Hyunjong; Lee, Won Woo; Park, So Yeon; Kim, Sang Eun

    2016-01-01

    The aim of the study was to compare the diagnostic performances of F-18 sodium fluoride positron emission tomography/computed tomography (bone PET/CT) and bone scintigraphy (BS) for the detection of thyroid cancer bone metastasis. We retrospectively enrolled 6 thyroid cancer patients (age = 44.7 ± 9.8 years, M:F = 1:5, papillary:follicular = 2:4) with suspected bone metastatic lesions in the whole body iodine scintigraphy or BS, who subsequently underwent bone PET/CT. Pathologic diagnosis was conducted for 4 lesions of 4 patients. Of the 17 suspected bone lesions, 10 were metastatic and 7 benign. Compared to BS, bone PET/CT exhibited superior sensitivity (10/10 = 100% vs. 2/10 = 20%, p = 0.008), and accuracy (14/17 = 82.4% vs. 7/17 = 41.2%, p 0.05). Bone PET/CT may be more sensitive and accurate than BS for the detection of thyroid cancer bone metastasis.

  2. F-8 sodium fluoride position emission tomography/computed tomography for detection of thyroid cancer bone metastasis compared with bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Jong; Lee, Won Woo; Park, So Yeon; Kim, Sang Eun [Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2016-04-15

    The aim of the study was to compare the diagnostic performances of F-18 sodium fluoride positron emission tomography/computed tomography (bone PET/CT) and bone scintigraphy (BS) for the detection of thyroid cancer bone metastasis. We retrospectively enrolled 6 thyroid cancer patients (age = 44.7 ± 9.8 years, M:F = 1:5, papillary:follicular = 2:4) with suspected bone metastatic lesions in the whole body iodine scintigraphy or BS, who subsequently underwent bone PET/CT. Pathologic diagnosis was conducted for 4 lesions of 4 patients. Of the 17 suspected bone lesions, 10 were metastatic and 7 benign. Compared to BS, bone PET/CT exhibited superior sensitivity (10/10 = 100% vs. 2/10 = 20%, p = 0.008), and accuracy (14/17 = 82.4% vs. 7/17 = 41.2%, p < 0.025). The specificity (4/7 = 57.1%) of bone PET/CT was not significantly different from that of BS (5/7 = 71.4%, p > 0.05). Bone PET/CT may be more sensitive and accurate than BS for the detection of thyroid cancer bone metastasis.

  3. Early clinical esophageal adenocarcinoma (cT1): Utility of CT in regional nodal metastasis detection and can the clinical accuracy be improved?

    Energy Technology Data Exchange (ETDEWEB)

    Betancourt Cuellar, Sonia L., E-mail: slbetancourt@mdanderson.org; Sabloff, Bradley, E-mail: bsabloff@mdanderson.org; Carter, Brett W., E-mail: bcarter2@mdanderson.org; Benveniste, Marcelo F., E-mail: mfbenveniste@mdanderson.org; Correa, Arlene M., E-mail: amcorrea@mdanderson.org; Maru, Dipen M., E-mail: dmaru@mdanderson.org; Ajani, Jaffer A., E-mail: jajani@mdanderson.org; Erasmus, Jeremy J., E-mail: jerasmus@mdanderson.org; Hofstetter, Wayne L., E-mail: whofstetter@mdanderson.org

    2017-03-15

    Introduction: Treatment of early esophageal cancer depends on the extent of the primary tumor and presence of regional lymph node metastasis.(RNM). Short axis diameter >10 mm is typically used to detect RNM. However, clinical determination of RNM is inaccurate and can result in inappropriate treatment. Purpose of this study is to evaluate the accuracy of a single linear measurement (short axis > 10 mm) of regional nodes on CT in predicting nodal metastasis, in patients with early esophageal cancer and whether using a mean diameter value (short axis + long axis/2) as well as nodal shape improves cN designation. Methods: CTs of 49 patients with cT1 adenocarcinoma treated with surgical resection alone were reviewed retrospectively. Regional nodes were considered positive for malignancy when round or ovoid and mean size >5 mm adjacent to the primary tumor and >7 mm when not adjacent. Results were compared with pN status after esophagectomy. Results: 18/49 patients had pN+ at resection. Using a single short axis diameter >10 mm on CT, nodal metastasis (cN) was positive in 7/49. Only 1 of these patients was pN+ at resection (sensitivity 5%, specificity 80%, accuracy 53%). Using mean size and morphologic criteria, cN was positive in 28/49. 11 of these patients were pN+ at resection (sensitivity 61%, specificity 45%, accuracy 51%). EUS with limited FNA of regional nodes resulted in 16/49 patients with pN+ being inappropriately designated as cN0. Conclusions: Evaluation of size, shape and location of regional lymph nodes on CT improves the sensitivity of cN determination compared with a short axis measurement alone in patients with cT1 esophageal cancer, although clinical utility is limited.

  4. Application of detecting cerebrospinal fluid circulating tumor cells in the diagnosis of meningeal metastasis of non-small cell lung cancer

    Directory of Open Access Journals (Sweden)

    Rong JIANG

    2014-08-01

    Full Text Available Objective To observe a new technology for the detection and enumeration of cerebrospinal fluid (CSF circulating tumor cells (CTCs in the diagnosis of non-small cell lung cancer (NSCLC with meningeal metastasis (MM.  Methods Five cases of NSCLC with MM that were diagnosed by CSF cytology were selected, and 20 ml CSF samples were obtained by lumbar puncture for every patient. The tumor marker immunostaining-fluorescence in situ hybridization (TM-iFISH technology was adapted to detect enrichment and enumeration of circulating tumor cells in 7.50 ml CSF samples; CSF cytology was checked in 10 ml CSF samples; CSF tumor markers were detected in 2.50 ml CSF samples. All of 5 cases were examined by MRI enhancement scan.  Results TM-iFISH detection found circulating tumor cells numbers ranging 18-1823/7.50 ml. Only 2 cases of patients with CSF cytology examination showed the tumor cells. The results of CSF tumor markers in all samples were higher than normal serum tumor markers detection results. The enhanced MRI scan of 5 cases revealed typical signs of MM.  Conclusions The TM-iFISH test showed certain advantages in the detection of malignant tumor cells in CSF. This technology may be a new method of detection and enumeration of tumor cells in CSF, but more studies are needed to prove its sensitivity and specificity. doi: 10.3969/j.issn.1672-6731.2014.08.011

  5. Probability of detection of clinical seizures using heart rate changes.

    Science.gov (United States)

    Osorio, Ivan; Manly, B F J

    2015-08-01

    Heart rate-based seizure detection is a viable complement or alternative to ECoG/EEG. This study investigates the role of various biological factors on the probability of clinical seizure detection using heart rate. Regression models were applied to 266 clinical seizures recorded from 72 subjects to investigate if factors such as age, gender, years with epilepsy, etiology, seizure site origin, seizure class, and data collection centers, among others, shape the probability of EKG-based seizure detection. Clinical seizure detection probability based on heart rate changes, is significantly (pprobability of detecting clinical seizures (>0.8 in the majority of subjects) using heart rate is highest for complex partial seizures, increases with a patient's years with epilepsy, is lower for females than for males and is unrelated to the side of hemisphere origin. Clinical seizure detection probability using heart rate is multi-factorially dependent and sufficiently high (>0.8) in most cases to be clinically useful. Knowledge of the role that these factors play in shaping said probability will enhance its applicability and usefulness. Heart rate is a reliable and practical signal for extra-cerebral detection of clinical seizures originating from or spreading to central autonomic network structures. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  6. Arduino-based noise robust online heart-rate detection.

    Science.gov (United States)

    Das, Sangita; Pal, Saurabh; Mitra, Madhuchhanda

    2017-04-01

    This paper introduces a noise robust real time heart rate detection system from electrocardiogram (ECG) data. An online data acquisition system is developed to collect ECG signals from human subjects. Heart rate is detected using window-based autocorrelation peak localisation technique. A low-cost Arduino UNO board is used to implement the complete automated process. The performance of the system is compared with PC-based heart rate detection technique. Accuracy of the system is validated through simulated noisy ECG data with various levels of signal to noise ratio (SNR). The mean percentage error of detected heart rate is found to be 0.72% for the noisy database with five different noise levels.

  7. A meta-analysis of lymph node metastasis rate for patients with thoracic oesophageal cancer and its implication in delineation of clinical target volume for radiation therapy

    Science.gov (United States)

    Ding, X; Zhang, J; Li, B; Wang, Z; Huang, W; Zhou, T; Wei, Y; Li, H

    2012-01-01

    Objectives The objective of this study was to pool the lymph node metastasis rate (LNMR) in patients with thoracic oesophageal cancer (TOC) and to determine which node level should be included when undergoing radiation therapy. Methods Qualified studies were identified on Medline, Embase, CBM and the Cochrane Library through to the end of April 2011. Pooled estimates of LNMR were obtained through a random-effect model. Possible effect modifiers which might lead to the statistical heterogeneity were identified through meta-regression, and further subgroup analyses of factors influencing LNMR were performed. Results 45 observational studies with a total of 18 415 patients were included in the meta-analysis. The pooled estimates of LNMR in upper, middle and lower TOC were 30.7%, 16.8% and 11.0% cervical, 42.0%, 21.1% and 10.5% upper mediastinal, 12.9%, 28.1% and 19.6% middle mediastinal, 2.6%, 7.8% and 23.0% lower mediastinal, and 9%, 21.4% and 39.9% abdominal, respectively. Lymph node metastasis most frequently happened to paratracheal, paraoesophageal, perigastric 106recR and station 7. The most obvious difference (≥15%) of LNMR between two-field and three-field lymphatic dissection occurred in cervical, paratracheal, 106recR and 108. Conclusions Through the meta-analysis, more useful information was obtained about clinical target volume (CTV) delineation of TOC patients treated with radiotherapy. However, our study is predominantly a description of squamous carcinoma and the results may not be valid for adenocarcinoma. PMID:22700258

  8. Fine-needle aspirates CYFRA 21-1 is a useful tumor marker for detecting axillary lymph node metastasis in breast cancer patients.

    Directory of Open Access Journals (Sweden)

    Jung Hyun Yoon

    Full Text Available INTRODUCTION: To assess whether the value of CYFRA21-1 in the aspirates of ultrasonography-guided fine-needle aspiration biopsy (US-FNAB can contribute to improving the performances of US-FNAB in the diagnosis of axillary lymph node (LN metastasis in breast cancer patients. METHODS: US-FNAB was performed in 156 axillary LNs in 152 breast cancer patients (mean age: 51.4 years, range: 17-92 years. Concentrations of CYFRA21-1 were measured from washouts of the syringe used during US-FNAB. Tumor marker concentrations, US-FNAB, intraoperative sentinel node biopsy (SNB, and surgical pathology results were reviewed and analyzed. For comparison, the values of CEA and CA15-3 were also measured from washouts. RESULTS: Among the 156 LNs, 75 (48.1% were benign, and 81 (51.9% were metastases. Mean concentrations of CYFRA21-1 were significantly higher in metastasis compared to benign LNs (P<0.001. US-FNAB combined to CYFRA21-1 showed significantly higher sensitivity, NPV, and accuracy compared to US-FNAB alone (all values P<0.05. All diagnostic indices of US-FNAB combined to CYFRA21-1 were significantly higher compared to US-FNAB combined with CEA or CA15-3 (all P<0.001. Of the 28 metastatic LNs which showed metastasis on SNB, CYFRA21-1 showed higher positive rate of 75.0% (CEA or CA15-3∶60.7%, P = 0.076. CONCLUSION: Measuring CYFRA 21-1 concentrations from US-FNAB aspirates improves sensitivity, NPV, and accuracy of US-FNAB alone, and may contribute to reducing up to 75.0% of unnecessary intraoperative SNB. Compared to CEA or CA15-3, CYFRA21-1 shows significantly higher performances when combined to US-FNAB in the preoperative diagnosis of LN metastasis in breast cancer patients.

  9. Detection of cervical lymph node metastasis in head and neck cancer patients with clinically N0 neck—a meta-analysis comparing different imaging modalities

    International Nuclear Information System (INIS)

    Liao, Li-Jen; Lo, Wu-Chia; Hsu, Wan-Lun; Wang, Chi-Te; Lai, Mei-Shu

    2012-01-01

    How to properly manage clinically negative neck of head and neck cancer patients is a controversial topic. Research is now directed toward finding a method sensitive enough to bring the risk of occult metastases below 20%. The aim of this review was to compare the diagnostic accuracy of different imaging modalities, including CT, MRI, PET and US, in clinically N0 head and neck cancer patients. For this systematic review and meta-analysis, PubMed and the Cochrane Database were searched for relevant original articles published up to May 2011. Inclusion criteria were as follows: articles were reported in English; CT, MRI, PET or US were performed to identify cervical metastases in clinically N0 head and neck squamous cell carcinoma; and data were sufficient for the calculation of true-positive or false-negative values. A bivariate random effect model was used to obtain pooled sensitivity and specificity. The positive and negative test probability of neck metastasis was generated based on Bayesian theory and collected data for different pre-test possibilities. Of the 168 identified relevant articles, 7 studies fulfilled all inclusion criteria for CT, 6 studies for MRI, 11 studies for PET and 8 studies for US. There was no difference in sensitivity and specificity among these imaging modalities, except CT was superior to US in specificity. The pooled estimates for sensitivity were 52% (95% confidence interval [CI], 39% ~ 65%), 65% (34 ~ 87%) 66% (47 ~ 80%), and 66% (45 ~ 77%), on a per-neck basis for CT, MRI, PET and US, respectively. The pooled estimates for specificity were 93% (87% ~ 97%), 81% (64 ~ 91%), 87% (77 ~ 93%), and 78% (71 ~ 83%) for CT, MRI, PET and US, respectively. With pre-examination nodal metastasis probabilities set at 10%, 20% and 30%, the post-exam probabilities of positive nodal metastasis rates were 47%, 66% and 77% for CT; 27%, 46% and 59% for MRI; 36%, 56% and 69% for PET; and 25%, 42% and 56% for US, respectively. Negative nodal metastasis

  10. Detection limit for rate fluctuations in inhomogeneous Poisson processes

    Science.gov (United States)

    Shintani, Toshiaki; Shinomoto, Shigeru

    2012-04-01

    Estimations of an underlying rate from data points are inevitably disturbed by the irregular occurrence of events. Proper estimation methods are designed to avoid overfitting by discounting the irregular occurrence of data, and to determine a constant rate from irregular data derived from a constant probability distribution. However, it can occur that rapid or small fluctuations in the underlying density are undetectable when the data are sparse. For an estimation method, the maximum degree of undetectable rate fluctuations is uniquely determined as a phase transition, when considering an infinitely long series of events drawn from a fluctuating density. In this study, we analytically examine an optimized histogram and a Bayesian rate estimator with respect to their detectability of rate fluctuation, and determine whether their detectable-undetectable phase transition points are given by an identical formula defining a degree of fluctuation in an underlying rate. In addition, we numerically examine the variational Bayes hidden Markov model in its detectability of rate fluctuation, and determine whether the numerically obtained transition point is comparable to those of the other two methods. Such consistency among these three principled methods suggests the presence of a theoretical limit for detecting rate fluctuations.

  11. Detection limit for rate fluctuations in inhomogeneous Poisson processes.

    Science.gov (United States)

    Shintani, Toshiaki; Shinomoto, Shigeru

    2012-04-01

    Estimations of an underlying rate from data points are inevitably disturbed by the irregular occurrence of events. Proper estimation methods are designed to avoid overfitting by discounting the irregular occurrence of data, and to determine a constant rate from irregular data derived from a constant probability distribution. However, it can occur that rapid or small fluctuations in the underlying density are undetectable when the data are sparse. For an estimation method, the maximum degree of undetectable rate fluctuations is uniquely determined as a phase transition, when considering an infinitely long series of events drawn from a fluctuating density. In this study, we analytically examine an optimized histogram and a Bayesian rate estimator with respect to their detectability of rate fluctuation, and determine whether their detectable-undetectable phase transition points are given by an identical formula defining a degree of fluctuation in an underlying rate. In addition, we numerically examine the variational Bayes hidden Markov model in its detectability of rate fluctuation, and determine whether the numerically obtained transition point is comparable to those of the other two methods. Such consistency among these three principled methods suggests the presence of a theoretical limit for detecting rate fluctuations.

  12. Fault Detection Using the Zero Crossing Rate | Osuagwu | Nigerian ...

    African Journals Online (AJOL)

    A method of fault detection based on the zero crossing rate of the signal, Z1, and the zero crossing rate of the first order difference signal. Z2, is presented. It is shown that the parameter pair (Z1, Z2) possesses adequate discriminating potential to classify a signature as good or defective. The parameter pair also carries ...

  13. ¹⁸F-fluorodeoxyglucose positron emission tomography-computed tomography for the evaluation of bone metastasis in patients with gastric cancer.

    Science.gov (United States)

    Ma, Dae Won; Kim, Jie-Hyun; Jeon, Tae Joo; Lee, Yong Chan; Yun, Mijin; Youn, Young Hoon; Park, Hyojin; Lee, Sang In

    2013-09-01

    The roles of positron emission tomography and bone scanning in identifying bone metastasis in gastric cancer are unclear. We compared the usefulness of positron emission tomography-computed tomography and scanning in detecting bone metastasis in gastric cancer. Data from 1485 patients diagnosed with gastric cancer who had undergone positron emission tomography-computed tomography and scanning were reviewed. Of 170 enrolled patients who were suspected of bone metastasis in either positron emission tomography or scanning, 81.2% were confirmed to have bone metastasis. The sensitivity, specificity, and accuracy were 93.5%, 25.0%, and 80.6%, respectively, for positron emission tomography and 93.5%, 37.5%, and 82.9%, respectively, for scanning. 87.7% of patients with bone metastasis showed positive findings on two modalities. 15.0% of solitary bone metastases were positive on positron emission tomography only. Positron emission tomography was superior to scanning for the detection of synchronous bone metastasis, but the two modalities were similar for the detection of metachronous bone metastasis. The concordance rate of response assessment after treatment between two modalities was moderate. Positron emission tomography-computed tomography may be more effective for the diagnosis of bone metastasis in the initial staging workup. Conversely, bone scanning and positron emission tomography-computed tomography may be similarly effective for the detection of metachronous bone metastasis. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  14. Rate modulation detection thresholds for cochlear implant users.

    Science.gov (United States)

    Brochier, Tim; McKay, Colette; McDermott, Hugh

    2018-02-01

    The perception of temporal amplitude modulations is critical for speech understanding by cochlear implant (CI) users. The present study compared the ability of CI users to detect sinusoidal modulations of the electrical stimulation rate and current level, at different presentation levels (80% and 40% of the dynamic range) and modulation frequencies (10 and 100 Hz). Rate modulation detection thresholds (RMDTs) and amplitude modulation detection thresholds (AMDTs) were measured and compared to assess whether there was a perceptual advantage to either modulation method. Both RMDTs and AMDTs improved with increasing presentation level and decreasing modulation frequency. RMDTs and AMDTs were correlated, indicating that a common processing mechanism may underlie the perception of rate modulation and amplitude modulation, or that some subject-dependent factors affect both types of modulation detection.

  15. The usefulness of MRI and PET imaging for the detection of parametrial involvement and lymph node metastasis in patients with cervical cancer

    International Nuclear Information System (INIS)

    Park, Won; Park, Young-Je; Huh, Seung-Jae

    2005-01-01

    The purpose of this study is to elucidate the usefulness of magnetic resonance imaging (MRI) and positron emission tomography (PET) for the detection of parametrial involvement and lymph node metastasis in patients with cervical cancer. Thirty-six patients with cervical cancer were retrospectively enrolled. MRI and PET scans were performed for all patients within a week before radical surgery. The criterion for malignancy on MRI was >1 cm short axis diameter of the suspected lymph node. On PET, only fluorodeoxyglucose (FDG) uptake was significantly higher than the background and, if this FDG uptake showed on at least two consecutive axial slices, then the lesion was considered as a malignancy. We compared the extent of tumor on the surgical findings with the International Federation of Gynecology and Obstetrics (FIGO) staging, MRI and PET scans. The accuracy of FIGO and MRI staging was 67 and 84.4%, respectively. The accuracy for detecting pelvic lymph node metastasis was better for PET than for MRI (78 versus 67%, respectively). All FDG uptake lymph nodes were confirmed as metastatic lymph nodes by pathological evaluation; this included five lymph nodes <1 cm in diameter. MRI provides an improved evaluation of local tumor extension, but PET is more useful for the evaluation of pelvic lymph nodes than MRI; however, PET still misses microscopic disease. Further studies are necessary to evaluate the usefulness of PET/computed tomography (CT) for the accuracy of the disease extension and the cost-effectiveness of MRI, PET or PET/CT in patients with cervical cancer. (author)

  16. DOUBLE COMPACT OBJECTS. III. GRAVITATIONAL-WAVE DETECTION RATES

    Energy Technology Data Exchange (ETDEWEB)

    Dominik, Michal; Belczynski, Krzysztof; Bulik, Tomasz [Astronomical Observatory, University of Warsaw, Al. Ujazdowskie 4, 00-478 Warsaw (Poland); Berti, Emanuele [Department of Physics and Astronomy, The University of Mississippi, University, MS 38677 (United States); O’Shaughnessy, Richard [Center for Gravitation, Cosmology, and Astrophysics, University of Wisconsin-Milwaukee, Milwaukee, WI (United States); Mandel, Ilya [School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Fryer, Christopher [CCS-2, MSD409, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Holz, Daniel E. [Enrico Fermi Institute, Department of Physics, and Kavli Institute for Cosmological Physics University of Chicago, Chicago, IL 60637 (United States); Pannarale, Francesco [School of Physics and Astronomy, Cardiff University, The Parade, Cardiff CF24 3AA (United Kingdom)

    2015-06-20

    The unprecedented range of second-generation gravitational-wave (GW) observatories calls for refining the predictions of potential sources and detection rates. The coalescence of double compact objects (DCOs)—i.e., neutron star–neutron star (NS–NS), black hole–neutron star (BH–NS), and black hole–black hole (BH–BH) binary systems—is the most promising source of GWs for these detectors. We compute detection rates of coalescing DCOs in second-generation GW detectors using the latest models for their cosmological evolution, and implementing inspiral-merger-ringdown gravitational waveform models in our signal-to-noise ratio calculations. We find that (1) the inclusion of the merger/ringdown portion of the signal does not significantly affect rates for NS–NS and BH–NS systems, but it boosts rates by a factor of ∼1.5 for BH–BH systems; (2) in almost all of our models BH–BH systems yield by far the largest rates, followed by NS–NS and BH–NS systems, respectively; and (3) a majority of the detectable BH–BH systems were formed in the early universe in low-metallicity environments. We make predictions for the distributions of detected binaries and discuss what the first GW detections will teach us about the astrophysics underlying binary formation and evolution.

  17. Probabilistic pipe fracture evaluations for leak-rate-detection applications

    International Nuclear Information System (INIS)

    Rahman, S.; Ghadiali, N.; Paul, D.; Wilkowski, G.

    1995-04-01

    Regulatory Guide 1.45, open-quotes Reactor Coolant Pressure Boundary Leakage Detection Systems,close quotes was published by the U.S. Nuclear Regulatory Commission (NRC) in May 1973, and provides guidance on leak detection methods and system requirements for Light Water Reactors. Additionally, leak detection limits are specified in plant Technical Specifications and are different for Boiling Water Reactors (BWRs) and Pressurized Water Reactors (PWRs). These leak detection limits are also used in leak-before-break evaluations performed in accordance with Draft Standard Review Plan, Section 3.6.3, open-quotes Leak Before Break Evaluation Proceduresclose quotes where a margin of 10 on the leak detection limit is used in determining the crack size considered in subsequent fracture analyses. This study was requested by the NRC to: (1) evaluate the conditional failure probability for BWR and PWR piping for pipes that were leaking at the allowable leak detection limit, and (2) evaluate the margin of 10 to determine if it was unnecessarily large. A probabilistic approach was undertaken to conduct fracture evaluations of circumferentially cracked pipes for leak-rate-detection applications. Sixteen nuclear piping systems in BWR and PWR plants were analyzed to evaluate conditional failure probability and effects of crack-morphology variability on the current margins used in leak rate detection for leak-before-break

  18. BIRDNEST: Bayesian Inference for Ratings-Fraud Detection

    OpenAIRE

    Hooi, Bryan; Shah, Neil; Beutel, Alex; Gunnemann, Stephan; Akoglu, Leman; Kumar, Mohit; Makhija, Disha; Faloutsos, Christos

    2015-01-01

    Review fraud is a pervasive problem in online commerce, in which fraudulent sellers write or purchase fake reviews to manipulate perception of their products and services. Fake reviews are often detected based on several signs, including 1) they occur in short bursts of time; 2) fraudulent user accounts have skewed rating distributions. However, these may both be true in any given dataset. Hence, in this paper, we propose an approach for detecting fraudulent reviews which combines these 2 app...

  19. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.

    Science.gov (United States)

    Klumpp, John; Brandl, Alexander

    2015-03-01

    A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.

  20. Detection of internal mammary lymph node metastasis with {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography in patients with stage III breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Min Jung; Lee, Jong Jin; Kim, Hye Ok; Chae, Sun-Young; Ryu, Jin-Sook; Moon, Dae Hyuk [University of Ulsan College of Medicine, Asan Medical Center, Department of Nuclear Medicine, Songpa-gu, Seoul (Korea, Republic of); Park, Seol Hoon [Ulsan University Hospital, Department of Nuclear Medicine, Ulsan (Korea, Republic of); Ahn, Sei Hyun; Lee, Jong Won; Son, Byung Ho [University of Ulsan College of Medicine, Asan Medical Center, Department of Surgery, Seoul (Korea, Republic of); Gong, Gyung-Yub [University of Ulsan College of Medicine, Asan Medical Center, Department of Pathology, Seoul (Korea, Republic of)

    2014-03-15

    The present study assessed the positive predictive value (PPV) of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for the detection of internal mammary node (IMN) metastasis in patients with clinical stage III breast cancer. Patients who were diagnosed with clinical stage III breast cancer and underwent pretreatment {sup 18}F-FDG PET/CT were retrospectively analyzed. The {sup 18}F-FDG PET/CT scans were prospectively reviewed by two board-certified nuclear medicine physicians in a blinded manner. The intensities of IMNs were graded into four categories (no activity and lower, similar, and higher activities than that of the mediastinal blood pool). IMNs were measured from the combined CT (largest diameter of the short axis). Histologic data of the IMNs were obtained by ultrasonography-guided fine-needle aspiration biopsy or surgical excision. The PPV was calculated for pathologically confirmed IMNs. Visual grade, maximum standardized uptake values (SUV{sub max}), and sizes were analyzed according to the pathology results. There were 249 clinical stage III breast cancer patients (age 48.0 ± 10.1 years, range 26-79 years) who had undergone initial {sup 18}F-FDG PET/CT prior to treatment. Excluding 33 cases of stage IV breast cancer, 62 of 216 patients had visible IMNs on {sup 18}F-FDG PET/CT, and histologic confirmation was obtained in 31 patients. There were 27 metastatic and four nonmetastatic nodes (PPV 87.1 %). Metastatic nodes mostly presented with visual grade 3 (83.9 %), and SUV{sub max} and size were 3.5 ± 4.3 and 5.6 ± 2.0 mm, respectively. {sup 18}F-FDG PET/CT has a high PPV for IMN metastasis in clinical stage III breast cancer, indicating the possibility of metastasis in IMNs with FDG uptake similar to/lower than that of the blood pool or small-sized nodes. (orig.)

  1. Efficacy for preoperative screening of liver metastasis using computed tomography and ultrasonography in patients with colon cancer

    International Nuclear Information System (INIS)

    Kotanagi, Hitoshi; Sato, Emi; Murakoshi, Satoshi

    2000-01-01

    To establish an effective examination system for preoperative evaluation of liver metastasis by colon cancer, we analyzed the sensitivity, cost, and efficacy of computed tomography (CT) and ultrasonography (US) in 354 patients (including 63 patients with liver metastasis). The presence or absence of liver metastasis was ultimately diagnosed 5 years after the operation. The sensitivity, specificity, and accuracy for detecting liver metastasis were 65%, 94%, and 89%, respectively for CT, 57%, 97%, and 91% for US, and 65%, 93%, and 88% for CT plus US, and there were no significant differences among them. Neither CT nor US could fully detect intrahepatic cancer spread. The cost of detection of one patient with liver metastasis was 6,298 points for plain CT, 20,169 points for enhanced CT, and 5,773 points for US. It was concluded that CT plus US should not be employed for preoperative assessment of liver metastasis, because the detection rate of the two modalities is not significantly different, and these modalities do not compensate for each other's defects. From the standpoint of the cost-benefit relationship, US should be selected for preoperative evaluation of liver metastasis. (author)

  2. Heart rate detection from an electronic weighing scale

    International Nuclear Information System (INIS)

    González-Landaeta, R; Casas, O; Pallàs-Areny, R

    2008-01-01

    We propose a novel technique for beat-to-beat heart rate detection based on the ballistocardiographic (BCG) force signal from a subject standing on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear and does not require any sensors attached to the body because it uses the load cells in the scale. We have devised an approach to estimate the sensitivity and frequency response of three commercial weighing scales to assess their capability to detect the BCG force signal. Static sensitivities ranged from 490 nV V −1 N −1 to 1670 nV V −1 N −1 . The frequency response depended on the subject's mass but it was broad enough for heart rate estimation. We have designed an electronic pulse detection system based on off-the-shelf integrated circuits to sense heart-beat-related force variations of about 0.24 N. The signal-to-noise ratio of the main peaks of the force signal detected was higher than 30 dB. A Bland–Altman plot was used to compare the RR time intervals estimated from the ECG and BCG force signals for 17 volunteers. The error was ±21 ms, which makes the proposed technique suitable for short-term monitoring of the heart rate

  3. Adenoma detection rate varies greatly during colonoscopy training

    NARCIS (Netherlands)

    van Doorn, Sascha C.; Klanderman, Robert B.; Hazewinkel, Yark; Fockens, Paul; Dekker, Evelien

    2015-01-01

    The adenoma detection rate (ADR) is considered the most important quality indicator for colonoscopy and varies widely among colonoscopists. It is unknown whether the ADR of gastroenterology consultants can already be predicted during their colonoscopy training. To evaluate the ADR of fellows in

  4. EUROCAT website data on prenatal detection rates of congenital anomalies

    NARCIS (Netherlands)

    Garne, Ester; Dolk, Helen; Loane, Maria; Boyd, Patricia A.

    2010-01-01

    The EUROCAT website www.eurocat-network.eu publishes prenatal detection rates for major congenital anomalies using data from European population-based congenital anomaly registers, covering 28% of the EU population as well as non-EU countries. Data are updated annually. This information can be

  5. Novel Method For Low-Rate Ddos Attack Detection

    Science.gov (United States)

    Chistokhodova, A. A.; Sidorov, I. D.

    2018-05-01

    The relevance of the work is associated with an increasing number of advanced types of DDoS attacks, in particular, low-rate HTTP-flood. Last year, the power and complexity of such attacks increased significantly. The article is devoted to the analysis of DDoS attacks detecting methods and their modifications with the purpose of increasing the accuracy of DDoS attack detection. The article details low-rate attacks features in comparison with conventional DDoS attacks. During the analysis, significant shortcomings of the available method for detecting low-rate DDoS attacks were found. Thus, the result of the study is an informal description of a new method for detecting low-rate denial-of-service attacks. The architecture of the stand for approbation of the method is developed. At the current stage of the study, it is possible to improve the efficiency of an already existing method by using a classifier with memory, as well as additional information.

  6. EUROCAT website data on prenatal detection rates of congenital anomalies

    DEFF Research Database (Denmark)

    Garne, Ester; Dolk, Helen; Loane, Maria

    2010-01-01

    The EUROCAT website www.eurocat-network.eu publishes prenatal detection rates for major congenital anomalies using data from European population-based congenital anomaly registers, covering 28% of the EU population as well as non-EU countries. Data are updated annually. This information can be us...

  7. Skeletal metastasis as detected by 18F-FDG PET with negative CT of the PET/CT: Frequency and impact on cancer staging and or management

    Directory of Open Access Journals (Sweden)

    Fatma Ahmed

    2016-10-01

    Full Text Available Objectives: The aim of our study is to assess the frequency of detection of PET positive CT negative skeletal metastases (SM and determine the impact of such detection on staging and/or management in patients who had FDG PET/CT as part of the cancer work up.Methods: We retrospectively reviewed 2000 18F-FDG PET/CT scans of known cancer patients. A log was kept to record cases of suspected SM with or without bone changes from the low-dose non-contrast CT. The presence or absence of SM was evaluated based on available pathological and clinical data. The impact of detection of such lesions on cancer staging and/or management was evaluated by a board certified oncologist.Results: Of the 2000 cases, 18F-FDG PET/CT suggested SM in 146/2000 (7.3%. Of those 146 cases, 105 (72% were positive on both PET and CT. The remaining 41 (28% had PET positive CT negative bone lesions. SM was confirmed in 36/41 (88% PET positive/CT negative cases. This was based on biopsy, imaging or clinical follow-up. The detection of PET positive CT negative SM did not change staging or management in 7/36 (19.4%. However, staging and/or management was affected in 29/36 (80.6%. Conclusions: SM is not uncommon in 18F-FDG PET/CT, as it accounts for 146/2000 (7.3% of cases. PET demonstrated FDG-avid SM without a CT abnormality in at least 36/146 (25%. Patients staging and or management changed in 29/36 (80.5%. We concluded that 18F-FDG PET is sensitive in detection of SM with significant impact on staging & or management. Key words18F-FDG PET/CT, Skeletal metastasis, PET positive, CT negative

  8. 68Ga-DOTA-NOC PET/CT in comparison with CT for the detection of bone metastasis in patients with neuroendocrine tumours

    International Nuclear Information System (INIS)

    Ambrosini, Valentina; Nanni, Cristina; Castellucci, Paolo; Allegri, Vincenzo; Montini, Giancarlo; Franchi, Roberto; Zompatori, Maurizio; Campana, Davide; Tomassetti, Paola; Rubello, Domenico; Fanti, Stefano

    2010-01-01

    To retrospectively evaluate the sensitivity, specificity and accuracy of 68 Ga-DOTA-NOC PET/CT and CT alone for the evaluation of bone metastasis in patients with neuroendocrine tumour (NET). From among patients with NET who underwent 68 Ga-DOTA-NOC PET/CT between April 2006 and November 2008 in our centre, 223 were included in the study. Criteria for inclusion were pathological confirmation of NET and a follow-up period of at least 10 months. PET and CT images were retrospectively reviewed by two nuclear medicine specialists and two radiologists, respectively, without knowledge of the patient history or the findings of other imaging modalities. PET data were compared with the CT findings. Interobserver agreement was evaluated in terms of the kappa score. Clinical and imaging follow-up were used as the standard of reference to evaluate the PET findings. PET was performed for staging (49/223), unknown primary tumour detection (24/223), restaging (32/223), restaging before radioimmunotherapy (1/223), evaluation during therapy (12/223), equivocal findings on conventional imaging (4/223 at the bone level; 61/223 at sites other than bone), and follow-up (40/223). A very high interobserver agreement was observed. CT detected at least one bone lesion in only 35 of 44 patients with a positive PET scan. In particular, PET showed more lesions in 20/35 patients, a lower number of lesions in 8/35, and the same number in 7/35. The characteristics of the lesions (sclerotic, lytic, mixed) on the basis of the CT report did not influence PET reading. PET revealed the presence of at least one bone metastasis in nine patients with a negative CT scan. Considering patients with a negative PET scan (179), CT showed equivocal findings at the bone level in three (single small sclerotic abnormality in two at the spine level, and bilateral small sclerotic abnormalities in the humeri, femurs and scapula). Clinical follow-up confirmed the PET findings in all patients; thus there were no false

  9. QRS peak detection for heart rate monitoring on Android smartphone

    Science.gov (United States)

    Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto

    2017-11-01

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.

  10. Correlation between tumor size and surveillance of lymph node metastasis for IB and IIA cervical cancer by magnetic resonance images

    International Nuclear Information System (INIS)

    Kim, See Hyung; Lee, Hee Jung; Kim, Young Whan

    2012-01-01

    Purpose: To assess the feasibility of preoperative MRI based measurement of tumor size with regard to lymph node (LN) metastasis in early uterine cervical cancer. Material and Methods: A retrospective review of patients with FIGO stage IB–IIA cervical cancer who underwent lymphadenectomy was performed. Diagnostic accuracy of MRI in detecting LN metastasis and rate of LN recurrence in terms of tumor size (≤4 cm versus >4 cm) were analyzed. ROC curve analysis was used to determine LN size for differentiating LN metastasis in terms of tumor size. P 4 cm revealed higher diagnostic accuracy of MRI in detecting LN metastasis (85.4% versus 50.6%, P = 0.023) and rate of LN recurrence (20.0% versus 6.4%, P = 0.031) in than those with size with ≤4 cm, the differences were statistically significant. Discriminant analysis of LN size for the differentiation of metastasis from non-metastasis resulted in cut-off values (11.8 mm; size with >4 cm versus 8.3 mm; size with ≤4 cm) and diagnostic accuracy (84.0% of size with >4 cm versus 72.0% of size with ≤4 cm). Conclusion: MRI has limited sensitivity, but high specificity in predicting surveillance of LN metastasis in the preoperative early cervical cancer, especially useful tool for patients with tumor size with >4 cm.

  11. Pipe fracture evaluations for leak-rate detection: Probabilistic models

    International Nuclear Information System (INIS)

    Rahman, S.; Wilkowski, G.; Ghadiali, N.

    1993-01-01

    This is the second in series of three papers generated from studies on nuclear pipe fracture evaluations for leak-rate detection. This paper focuses on the development of novel probabilistic models for stochastic performance evaluation of degraded nuclear piping systems. It was accomplished here in three distinct stages. First, a statistical analysis was conducted to characterize various input variables for thermo-hydraulic analysis and elastic-plastic fracture mechanics, such as material properties of pipe, crack morphology variables, and location of cracks found in nuclear piping. Second, a new stochastic model was developed to evaluate performance of degraded piping systems. It is based on accurate deterministic models for thermo-hydraulic and fracture mechanics analyses described in the first paper, statistical characterization of various input variables, and state-of-the-art methods of modem structural reliability theory. From this model. the conditional probability of failure as a function of leak-rate detection capability of the piping systems can be predicted. Third, a numerical example was presented to illustrate the proposed model for piping reliability analyses. Results clearly showed that the model provides satisfactory estimates of conditional failure probability with much less computational effort when compared with those obtained from Monte Carlo simulation. The probabilistic model developed in this paper will be applied to various piping in boiling water reactor and pressurized water reactor plants for leak-rate detection applications

  12. Nodal metastasis in thyroid cancer

    International Nuclear Information System (INIS)

    Samuel, A.M.

    1999-01-01

    The biological behavior and hence the prognosis of thyroid cancer (TC) depends among other factors on the extent of spread of the disease outside the thyroid bed. This effect is controversial, especially for nodal metastasis of well differentiated thyroid carcinoma (WDC). Nodal metastasis at the time of initial diagnosis behaves differently depending on the histology, age of the patient, presence of extrathyroidal extension, and the sex of the individual. The type of the surgery, administration of 131 I and thyroxin suppression also to some extent influence the rate of recurrence and mortality. Experience has shown that it is not as innocuous as a small intrathyroidal tumor without any invasion outside the thyroid bed and due consideration should be accorded to the management strategies for handling patients with nodal metastasis

  13. Primary neuroendocrine carcinoma of breast with liver and bone metastasis detected with fluorine-18 fluorodeoxyglucose-positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Kamaleshwaran, Koramadai Karuppusamy; Mohanan, Vyshak; Shibu, Deepu; Radhakrishnan, Edathuruthy Kalarikal; Shinto, Ajit Sugunan

    2014-01-01

    Cases of primary neuroendocrine carcinoma (NEC) of the breast have been reported, though rare. We report the case of a 45-year-old woman presented with jaundice and evaluated to have liver metastasis from neuroendocrine origin. She underwent whole body positron emission tomography/computed tomography, which showed left breast lesion and bone metastasis. Fine-needle aspiration (FNA) of breast revealed a NEC. A diagnosis of a primary NEC of the breast was rendered with hepatic and bone metastasis. She was treated with peptide receptor radionuclide therapy and is on follow-up

  14. Post site metastasis of breast cancer after video-assisted thoracic surgery for pulmonary metastasis of breast cancer: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Mee Hyun; Hwang, Ji Young; Hyun, Su Jeong; Lee, Yul; Woo, Ji Young; Yang, Ik; Hong, Hye Sook; Kim, Han Myun [Dept. of Radiology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul (Korea, Republic of)

    2016-05-15

    We reported a case of port site metastasis in a 57-year-old patient who underwent video-assisted thoracic surgery (VATS) resection of pulmonary metastasis from breast cancer. Port site metastasis after VATS is very rare in patients with breast cancer. However, when suspicious lesions are detected near the port site in patients who have undergone VATS for pulmonary metastasis, port site metastasis should be considered in the differential diagnosis.

  15. CT manifestation of peritoneal metastasis

    International Nuclear Information System (INIS)

    Cha, Soon Joo; Kang, Eun Young; Suh, Won Hyuck

    1989-01-01

    Peritoneal metastasis is frequent mode of dissemination of intraabdominal malignancies. Radiologic diagnosis of peritoneal metastasis has relied on indirect evidence on a barium UGI series and small bowel examination. With the advent of CT scanning, CT is capable of direct imaging of peritoneum. The sensitivity of CT in detecting peritoneal metastasis and CT manifestation of peritoneal metastatic lesions had reported occasionally, but rarely in Korea. So, authors illustrated the CT manifestation of peritoneal metastatic lesions in 32 cases of macroscopically proven cases in laparoscopy or laparotomy in Korea University Hae Wha Hospital during recent 4 years. The results are as follows. 1. Of total 32 cases, 18 cases were male and 14 cases were female. Age incidence was the most common in 6th decade. 2. The most common type of malignancy that cause peritoneal metastasis was the stomach cancer and next common type of malignancies were pancreas cancer in men and ovarian cancer in women. 3. Of total 32 cases of peritoneal metastasis which was confirmed by laparoscopy or laparotomy macroscopically, 23 cases (72%) were detected peritoneal thickening and/or omental pathology by CT, and the remaining 9 cases (28%) were not detected by CT. 4. Ascites was present in 19 cases (59%). 5. Parietal peritoneal thickening was present in 16 cases (50%) by CT and sheetlike pattern was the most common findings. The patterns of peritoneal thickening was relatively nonspecific and was not correlated with primary tumor type. 6. Tumor involvement of greater omentum by CT was present in 19 cases (59%). There were 7 cases of smudged appearance pattern, 6 cases of nodular pattern, 6 cases of omental cake pattern and no cystic mass pattern. The patterns of omental pathology was relatively nonspecific and was nor correlated with primary tumor type

  16. Detectability and detection rate of acute cerebral hemisphere infarcts on CT and diffusion-weighted MRI

    International Nuclear Information System (INIS)

    Urbach, H.; Flacke, S.; Keller, E.; Textor, J.; Berlis, A.; Reul, J.; Schild, H.H.; Hartmann, A.; Solymosi, L.

    2000-01-01

    Our purpose was to compare the detectability and detection rate of acute ischaemic cerebral hemisphere infarcts on CT and diffusion-weighted MRI (DWI). We investigated 32 consecutive patients with acute hemisphere stroke with unenhanced CT and DWI within 6 h of stroke onset. The interval between CT and DWI ranged from 15 to 180 min (mean 60 min). Infarct detectability on CT and DWI was determined by comparing the initial CT, DWI and later reference images in a consensus reading of five independent examiners. The ''true'' detection rate was assessed by analysing all single readings. Two patients had intracerebral haematomas on DWI and CT and were excluded. There were 27 patients with ischaemic infarcts; all were visible on DWI and proven by follow-up. DWI was negative in three patients without a final diagnosis of infarct (100 % sensitivity, 100 % specificity, χ 2 = 30, P 2 = 1.48, P = 0.224). With regard to the single readings (30 examinations x 5 examiners = 150 readings), 63 CT readings were true positive and 72 false negative (sensitivity 47 %, specificity 86 %, χ 2 = 2.88, P = 0.089). Of the DWI readings 128 were true positive and 7 false negative (sensitivity 95 %, specificity 87 %, χ 2 = 70.67, P < 0.0001). Interobserver agreement was substantial for CT (χ= 0.72, 95 % confidence interval, 0.6-0.84) and DWI (χ= 0.82, 95 % confidence interval, 0.46-1). Taken together, detectability and detection rate of acute (< 6 h) hemisphere infarcts are significantly higher with DWI than with CT. (orig.)

  17. Palatine Tonsillar Metastasis of Small-Cell Neuroendocrine Carcinoma from the Lung Detected by FDG-PET/CT After Tonsillectomy: A Case Report

    International Nuclear Information System (INIS)

    Chen, Xiao-Hong; Bao, Yang-Yang; Zhou, Shui-Hong; Wang, Qin-Ying; Zhao, Kui

    2013-01-01

    Metastasis from a malignant tumor to the palatine tonsils is rare, accounting for only 0.8% of all tonsillar tumors, with only 100 cases reported in the English-language literature. Various malignant lung carcinomas may metastasize to the tonsils. A few cases of tonsillar metastasis from neuroendocrine lung carcinoma have been reported. A 67-year-old female underwent a right tonsillectomy because of a sore throat and an enlarged right tonsil. The postoperative pathology showed right tonsillar small cell neuroendocrine carcinoma (SCNC). Fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) demonstrated metabolic activity in the lower lobe of the right lung. In addition, hypermetabolic foci were noted in the lymph nodes of the right neck and mediastinum. A needle biopsy of the pulmonary mass showed SCNC. The patient received chemotherapy and died of multiple distant metastases after 6 months. This is the first report using PET/CT to evaluate tonsillar metastasis from lung SCNC

  18. A Comparative Study of Data Mining Algorithms for High Detection Rate in Intrusion Detection System

    Directory of Open Access Journals (Sweden)

    Nabeela Ashraf

    2018-01-01

    Full Text Available Due to the fast growth and tradition of the internet over the last decades, the network security problems are increasing vigorously. Humans can not handle the speed of processes and the huge amount of data required to handle network anomalies. Therefore, it needs substantial automation in both speed and accuracy. Intrusion Detection System is one of the approaches to recognize illegal access and rare attacks to secure networks. In this proposed paper, Naive Bayes, J48 and Random Forest classifiers are compared to compute the detection rate and accuracy of IDS. For experiments, the KDD_NSL dataset is used.

  19. High detection rate of dog circovirus in diarrheal dogs.

    Science.gov (United States)

    Hsu, Han-Siang; Lin, Ting-Han; Wu, Hung-Yi; Lin, Lee-Shuan; Chung, Cheng-Shu; Chiou, Ming-Tang; Lin, Chao-Nan

    2016-06-17

    Diarrhea is one of the most common clinical symptoms reported in companion animal clinics. Dog circovirus (DogCV) is a new mammalian circovirus that is considered to be a cause of alimentary syndromes such as diarrhea, vomiting and hemorrhagic enteritis. DogCV has previously only been identified in the United States, Italy, Germany (GeneBank accession number: KF887949) and China (GeneBank accession number: KT946839). Therefore, the aims of this study were to determine the prevalence of DogCV in Taiwan and to explore the correlation between diarrhea and DogCV infection. Clinical specimens were collected between 2012 and 2014 from 207 dogs suffering from diarrhea and 160 healthy dogs. In this study, we developed a sensitive and specific SYBR Green-based real-time PCR assays to detected DogCV in naturally infected animals. Of the analyzed fecal samples from diarrheal dogs and health dogs, 58 (28.0 %) and 19 (11.9 %), respectively, were DogCV positive. The difference in DogCV prevalence was highly significant (P = 0.0002755) in diarrheal dogs. This is the first study to reveal that DogCV is currently circulating in domestic dogs in Taiwan and to demonstrate its high detection rate in dogs with diarrhea.

  20. Detection of disseminated tumour cells in blood and bone marrow samples of patients undergoing hepatic resection for metastasis of colorectal cancer

    NARCIS (Netherlands)

    Vlems, F. A.; Diepstra, J. H. S.; Punt, C. J. A.; Ligtenberg, M. J. L.; Cornelissen, I. M. H. A.; van Krieken, J. H. J. M.; Wobbes, T.; van Muijen, G. N. P.; Ruers, T. J. M.

    2003-01-01

    In 50-60 per cent of patients who undergo hepatic resection for metastasis of colorectal cancer the first site of tumour recurrence is extrahepatic, indicating the presence of more extensive disease at the time of resection. The aim of this study was to evaluate whether the presence of disseminated

  1. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources

    Energy Technology Data Exchange (ETDEWEB)

    Klumpp, John [Colorado State University, Department of Environmental and Radiological Health Sciences, Molecular and Radiological Biosciences Building, Colorado State University, Fort Collins, Colorado, 80523 (United States)

    2013-07-01

    We propose a radiation detection system which generates its own discrete sampling distribution based on past measurements of background. The advantage to this approach is that it can take into account variations in background with respect to time, location, energy spectra, detector-specific characteristics (i.e. different efficiencies at different count rates and energies), etc. This would therefore be a 'machine learning' approach, in which the algorithm updates and improves its characterization of background over time. The system would have a 'learning mode,' in which it measures and analyzes background count rates, and a 'detection mode,' in which it compares measurements from an unknown source against its unique background distribution. By characterizing and accounting for variations in the background, general purpose radiation detectors can be improved with little or no increase in cost. The statistical and computational techniques to perform this kind of analysis have already been developed. The necessary signal analysis can be accomplished using existing Bayesian algorithms which account for multiple channels, multiple detectors, and multiple time intervals. Furthermore, Bayesian machine-learning techniques have already been developed which, with trivial modifications, can generate appropriate decision thresholds based on the comparison of new measurements against a nonparametric sampling distribution. (authors)

  2. Cavitary pulmonar metastasis

    International Nuclear Information System (INIS)

    Marchiori, E.; Matushita, J.P.K.; Azevedo, C.M. de

    1984-01-01

    Seven cases of cavitary lung metastasis, four from head and neck neoplasma, two from uterine carcinoma and one from hepatoma are reported. The physiopathology and the most common sites of this kind of lesion are discussed. The rarity of the solitary excavated metastasis from hepatoma, not reported previously in the literature reviewed, is emphasized. (Author) [pt

  3. MYC is a metastasis gene for non-small-cell lung cancer.

    Directory of Open Access Journals (Sweden)

    Ulf R Rapp

    Full Text Available BACKGROUND: Metastasis is a process by which cancer cells learn to form satellite tumors in distant organs and represents the principle cause of death of patients with solid tumors. NSCLC is the most lethal human cancer due to its high rate of metastasis. METHODOLOGY/PRINCIPAL FINDINGS: Lack of a suitable animal model has so far hampered analysis of metastatic progression. We have examined c-MYC for its ability to induce metastasis in a C-RAF-driven mouse model for non-small-cell lung cancer. c-MYC alone induced frank tumor growth only after long latency at which time secondary mutations in K-Ras or LKB1 were detected reminiscent of human NSCLC. Combination with C-RAF led to immediate acceleration of tumor growth, conversion to papillary epithelial cells and angiogenic switch induction. Moreover, addition of c-MYC was sufficient to induce macrometastasis in liver and lymph nodes with short latency associated with lineage switch events. Thus we have generated the first conditional model for metastasis of NSCLC and identified a gene, c-MYC that is able to orchestrate all steps of this process. CONCLUSIONS/SIGNIFICANCE: Potential markers for detection of metastasis were identified and validated for diagnosis of human biopsies. These markers may represent targets for future therapeutic intervention as they include genes such as Gata4 that are exclusively expressed during lung development.

  4. Biometric Quantization through Detection Rate Optimized Bit Allocation

    Directory of Open Access Journals (Sweden)

    C. Chen

    2009-01-01

    Full Text Available Extracting binary strings from real-valued biometric templates is a fundamental step in many biometric template protection systems, such as fuzzy commitment, fuzzy extractor, secure sketch, and helper data systems. Previous work has been focusing on the design of optimal quantization and coding for each single feature component, yet the binary string—concatenation of all coded feature components—is not optimal. In this paper, we present a detection rate optimized bit allocation (DROBA principle, which assigns more bits to discriminative features and fewer bits to nondiscriminative features. We further propose a dynamic programming (DP approach and a greedy search (GS approach to achieve DROBA. Experiments of DROBA on the FVC2000 fingerprint database and the FRGC face database show good performances. As a universal method, DROBA is applicable to arbitrary biometric modalities, such as fingerprint texture, iris, signature, and face. DROBA will bring significant benefits not only to the template protection systems but also to the systems with fast matching requirements or constrained storage capability.

  5. FDG PET/CT and Mediastinal Nodal Metastasis Detection in Stage T1 Non-Small Cell Lung Cancer: Prognostic Implications

    International Nuclear Information System (INIS)

    Shin, Kyung Min; Lee, Kyung Soo; Shim, Young Mog; Kim, Jhin Gook; Kim, Byung Tae; Kwon, O Jung; Park, Keun Chil

    2008-01-01

    We aimed to compare the prognoses of patients with pathologically true negative (P-TN) N2 and PET/CT false negative (FN) results in stage T1 nonsmall cell lung cancer (NSCLC). Our institutional review board approved this retrospective study with a waiver of informed consent. The study included 184 patients (124 men and 60 women; mean age, 59 years) with stage T1 NSCLC who underwent an integrated PET/CT and surgery. After estimating the efficacy of PET/CT for detecting N2 disease, we determined and compared disease-free survival (DFS) rates in three groups (P-TN [n = 161], PET/CT FN [n = 12], and PET/CT true positive [TP, n = 11]) using the Kaplan-Meier analysis and log-rank test. Pathologic N2 disease was observed in 23 (12%) patients. PET/CT had an N2 disease detection sensitivity of 48% (11 of 23 patients), a specificity of 95% (153 of 161), and an accuracy of 89% (164 of 184). The 3-year DFS rate in the PET/CT FN group (31%, 95% confidence interval [CI]; 13.6-48.0%) was similar to that of the TP group (16%, 95% CI; 1.7-29.5%) (p = 0.649), but both groups had significantly shorter DFS rates than the P-TN group (77%, 95% CI; 72.0- 81.2%) (p < 0.001). The PET/CT shows a high specificity, but low sensitivity for detecting N2 disease in stage T1 NSCLC. Patients with PET/CT FN N2 disease have survival rates similar to PET/CT TP N2 disease patients, which are both substantially shorter than the survival rate of P-TN patients

  6. Magnetic Resonance Imaging of Liver Metastasis.

    Science.gov (United States)

    Karaosmanoglu, Ali Devrim; Onur, Mehmet Ruhi; Ozmen, Mustafa Nasuh; Akata, Deniz; Karcaaltincaba, Musturay

    2016-12-01

    Liver magnetic resonance imaging (MRI) is becoming the gold standard in liver metastasis detection and treatment response assessment. The most sensitive magnetic resonance sequences are diffusion-weighted images and hepatobiliary phase images after Gd-EOB-DTPA. Peripheral ring enhancement, diffusion restriction, and hypointensity on hepatobiliary phase images are hallmarks of liver metastases. In patients with normal ultrasonography, computed tomography (CT), and positron emission tomography (PET)-CT findings and high clinical suspicion of metastasis, MRI should be performed for diagnosis of unseen metastasis. In melanoma, colon cancer, and neuroendocrine tumor metastases, MRI allows confident diagnosis of treatment-related changes in liver and enables differential diagnosis from primary liver tumors. Focal nodular hyperplasia-like nodules in patients who received platinum-based chemotherapy, hypersteatosis, and focal fat can mimic metastasis. In cancer patients with fatty liver, MRI should be preferred to CT. Although the first-line imaging for metastases is CT, MRI can be used as a problem-solving method. MRI may be used as the first-line method in patients who would undergo curative surgery or metastatectomy. Current limitation of MRI is low sensitivity for metastasis smaller than 3mm. MRI fingerprinting, glucoCEST MRI, and PET-MRI may allow simpler and more sensitive diagnosis of liver metastasis. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Mitochondrial markers predict recurrence, metastasis and tamoxifen-resistance in breast cancer patients: Early detection of treatment failure with companion diagnostics.

    Science.gov (United States)

    Sotgia, Federica; Fiorillo, Marco; Lisanti, Michael P

    2017-09-15

    Here, we used a data-mining and informatics approach to discover new biomarkers of resistance to hormonal therapy in breast cancer. More specifically, we investigated whether nuclear-encoded genes associated with mitochondrial biogenesis can be used to predict tumor recurrence, distant metastasis and treatment failure in high-risk breast cancer patients. Overall, this strategy allowed us to directly provide in silico validation of the prognostic value of these mitochondrial components in large and clinically relevant patient populations, with >15 years of follow-up data. For this purpose, we employed a group of 145 ER(+) luminal A breast cancer patients, with lymph-node (LN) metastasis at diagnosis, that were treated with tamoxifen, but not any chemotherapy agents. Using this approach, we identified >60 new individual mitochondrial biomarkers that predicted treatment failure and tumor recurrence, with hazard-ratios (HR) of up to 4.17 ( p =2.2e-07). These include mitochondrial chaperones (HSPD1, HSPA9), membrane proteins (VDAC2, TOMM70A) and anti-oxidants (SOD2), as well as 18 different mitochondrial ribosomal proteins (MRPs) and >20 distinct components of the OXPHOS complexes. In addition, we combined 4 mitochondrial proteins (HSPD1, UQCRB, MRPL15, COX17), to generate a compact mitochondrial gene signature, associated with a HR of 5.34 ( p =1e-09). This signature also successfully predicted distant metastasis and was effective in larger groups of ER(+) ( N =2,447), basal ( N =540) and HER2(+) ( N =193) breast cancers. It was also effective in all breast cancers ( N =3,180), if considered together as a single group. Based on this analysis, we conclude that mitochondrial biogenesis should be considered as a new therapeutic target for overcoming tumor recurrence, distant metastasis and treatment failure in patients with breast cancer. In summary, we identified individual mitochondrial biomarkers and 2 compact mitochondrial gene signatures that can be used to predict

  8. Molecular Mechanism Underlying Lymphatic Metastasis in Pancreatic Cancer

    Directory of Open Access Journals (Sweden)

    Zhiwen Xiao

    2014-01-01

    Full Text Available As the most challenging human malignancies, pancreatic cancer is characterized by its insidious symptoms, low rate of surgical resection, high risk of local invasion, metastasis and recurrence, and overall dismal prognosis. Lymphatic metastasis, above all, is recognized as an early adverse event in progression of pancreatic cancer and has been described to be an independent poor prognostic factor. It should be noted that the occurrence of lymphatic metastasis is not a casual or stochastic but an ineluctable and designed event. Increasing evidences suggest that metastasis-initiating cells (MICs and the microenvironments may act as a double-reed style in this crime. However, the exact mechanisms on how they function synergistically for this dismal clinical course remain largely elusive. Therefore, a better understanding of its molecular and cellular mechanisms involved in pancreatic lymphatic metastasis is urgently required. In this review, we will summarize the latest advances on lymphatic metastasis in pancreatic cancer.

  9. A novel hardware implementation for detecting respiration rate using photoplethysmography.

    Science.gov (United States)

    Prinable, Joseph; Jones, Peter; Thamrin, Cindy; McEwan, Alistair

    2017-07-01

    Asthma is a serious public health problem. Continuous monitoring of breathing may offer an alternative way to assess disease status. In this paper we present a novel hardware implementation for the capture and storage of a photoplethysmography (PPG) signal. The LED duty cycle was altered to determine the effect on respiratory rate accuracy. The oximeter was mounted to the left index finger of ten healthy volunteers. The breathing rate derived from the oximeter was validated against a nasal airflow sensor. The duty cycle of a pulse oximeter was changed between 5%, 10% and 25% at a sample rate of 500 Hz. A PPG signal and reference signal was captured for each duty cycle. The PPG signals were post processed in Matlab to derive a respiration rate using an existing Matlab toolbox. At a 25% duty cycle the RMSE was <;2 breaths per minute for the top performing algorithm. The RMSE increased to over 5 breaths per minute when the duty cycle was reduced to 5%. The power consumed by the hardware for a 5%, 10% and 25% duty cycle was 5.4 mW, 7.8 mW, and 15 mW respectively. For clinical assessment of respiratory rate, a RSME of <;2 breaths per minute is recommended. Further work is required to determine utility in asthma management. However for non-clinical applications such as fitness tracking, lower accuracy may be sufficient to allow a reduced duty cycle setting.

  10. The imunocytochemical advances in prognosis of metastasis radioiodine resistant of papillary thyroid carcinoma

    International Nuclear Information System (INIS)

    Zelyins'ka, G.V.

    2015-01-01

    The topical issues is the problem of prognosis of metastasis radioiodine resistant metastasis. We offered the methods of prognosis of metastasis radioiodine resistant of papillary thyroid carcinoma with the help of immunocytochemical detection of the cytokeratin 17 and thyroid peroxidase. With the purpose of prognosis of metastasis radioiodine resistibility the cytokeratin 17 is taped in punctates of primary papillary carcinomas. This approach allows predict response of metastases on radioiodine therapy to choose proper therapeutic approach

  11. Lung Metastasis Mimicking Fingertip Infection

    Science.gov (United States)

    Soylemez, Salih; Demiroglu, Murat; Yayla, Mehmet Ali; Ozkan, Korhan; Alpan, Bugra; Ozger, Harzem

    2015-01-01

    Metastasis fingers (acral metastasis) are finding a poor prognosis. Past medical history should be questioned and metastasis from primary tumor should be kept in mind in patients with pain, swelling, and hyperemia in fingers. Successful surgical treatment on acral metastasis does not extend the life expectancy; however, it reduces the patient's pain during his terminal period, saves the functions of the limb, and increases life comfort. PMID:26236517

  12. Lung Metastasis Mimicking Fingertip Infection

    Directory of Open Access Journals (Sweden)

    Salih Soylemez

    2015-01-01

    Full Text Available Metastasis fingers (acral metastasis are finding a poor prognosis. Past medical history should be questioned and metastasis from primary tumor should be kept in mind in patients with pain, swelling, and hyperemia in fingers. Successful surgical treatment on acral metastasis does not extend the life expectancy; however, it reduces the patient’s pain during his terminal period, saves the functions of the limb, and increases life comfort.

  13. A Case Report of Intraocular Metastasis Treated with Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ok Bae; Byun, Sang Jun; Kim, Kwang Soo; Kim, Jin Hee [Keimyung University School of Medicine, Daegu (Korea, Republic of); Lee, Ho Jun [Daegu Catholic University School of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    Intraocular metastasis is the most common malignancy of the eye. The frequency of intraocular metastasis in all the patients dying of cancer is about 12% and ocular metastases will be detected more frequently in the future because the patients with malignant tumor are now living longer. Intraocular metastasis can cause a serious clinical problem such as blindness. The early recognition and treatment of intraocular metastasis are very important clinical oncologic issues to maintain vision and to maximize the quality of life. However, significance of intraocular metastasis is still under-evaluated for practicing oncologists. External beam radiotherapy is a safe, effective palliative treatment in terms of preserving both the vision and the eye globe.

  14. Gastric Metastasis of Triple Negative Invasive Lobular Carcinoma.

    Science.gov (United States)

    Geredeli, Caglayan; Dogru, Osman; Omeroglu, Ethem; Yilmaz, Farise; Cicekci, Faruk

    2015-05-05

    Invasive lobular carcinomas are the second most common type (5% to 15%) of invasive breast carcinomas. The most frequent sites of breast cancer metastasis are the local and distant lymph nodes, brain, lung, liver, and bones; metastasis to the gastrointestinal system, especially to the stomach, is rare. When a mass is detected in an unusual place in a patient with invasive lobular carcinoma, it should be kept in mind that such a mass may be either a second primary carcinoma or the metastasis of an invasive lobular carcinoma. In this report, we present a case of gastric metastasis from triple-negative invasive lobular breast cancer. It is important to make an accurate diagnosis by distinguishing gastric metastasis from breast cancer in order to select the best initial treatment for systemic diseases of breast cancer. Considering our case, healthcare professionals should take into account that cases with invasive lobular breast cancer may experience unusual metastases.

  15. Atrial fibrillation detection by heart rate variability in Poincare plot.

    Science.gov (United States)

    Park, Jinho; Lee, Sangwook; Jeon, Moongu

    2009-12-11

    Atrial fibrillation (AFib) is one of the prominent causes of stroke, and its risk increases with age. We need to detect AFib correctly as early as possible to avoid medical disaster because it is likely to proceed into a more serious form in short time. If we can make a portable AFib monitoring system, it will be helpful to many old people because we cannot predict when a patient will have a spasm of AFib. We analyzed heart beat variability from inter-beat intervals obtained by a wavelet-based detector. We made a Poincare plot using the inter-beat intervals. By analyzing the plot, we extracted three feature measures characterizing AFib and non-AFib: the number of clusters, mean stepping increment of inter-beat intervals, and dispersion of the points around a diagonal line in the plot. We divided distribution of the number of clusters into two and calculated mean value of the lower part by k-means clustering method. We classified data whose number of clusters is more than one and less than this mean value as non-AFib data. In the other case, we tried to discriminate AFib from non-AFib using support vector machine with the other feature measures: the mean stepping increment and dispersion of the points in the Poincare plot. We found that Poincare plot from non-AFib data showed some pattern, while the plot from AFib data showed irregularly irregular shape. In case of non-AFib data, the definite pattern in the plot manifested itself with some limited number of clusters or closely packed one cluster. In case of AFib data, the number of clusters in the plot was one or too many. We evaluated the accuracy using leave-one-out cross-validation. Mean sensitivity and mean specificity were 91.4% and 92.9% respectively. Because pulse beats of ventricles are less likely to be influenced by baseline wandering and noise, we used the inter-beat intervals to diagnose AFib. We visually displayed regularity of the inter-beat intervals by way of Poincare plot. We tried to design an

  16. 18F-FDG PET/CT显像对乳腺癌术后复发及转移的诊断价值%18F-FDG PET/CT in detection of recurrence and metastasis of breast cancer

    Institute of Scientific and Technical Information of China (English)

    林丽莉; 吴湖炳; 王全师

    2011-01-01

    目的 探讨18F-脱氧葡萄糖正电子发射体层摄影术(FDG PET)/CT显像对乳腺癌术后复发、转移的诊断价值.方法 对乳腺癌术后患者104例进行全身18F-FDG PET/CT显像检查.复发或转移灶依据手术或活组织病理学检查、多种影像学检查及临床随访确诊,随访时间大于6个月.结果 104例患者中,肿瘤复发、转移52例.以患者为单位计算,18F-FDG PET/CT诊断乳腺癌术后复发和(或)转移的灵敏度为100%,特异性为98.1%,准确性为99.0%,阳性预测值为98.1%,阴性预测值为100%.以病灶为单位计算,18F-FDG PET/CT诊断乳腺癌术后复发和(或)转移的灵敏度为98.3%,特异性为75.0%,准确性为96.8%,阳性预测值为98.3%,阴性预测值为75.0%.18F-FDG PET/CT显像使8例(15.4%)患者改变了临床再分期,其中7例提高了临床再分期、1例降低了临床再分期.结论 18F-FDG PET/CT对乳腺癌术后复发和(或)转移的诊断具有重要临床价值.%Objective To evaluate the value of positron emission tomography/computed tomography(PET/CT)with 18 F-fluoro deoxy-glucose(18 F-FDG)in detecting recurrence and metastasis of breast cancer. Methods 18 F-FDG PET/CT was studied in 104 patients with breast cancer after surgery. The diagnosis of recurrent tumor and ( or) metastasts was based on pathoiogic examination, multi-modality imagings and clinical follow-up for more than 6 months. The diagnostic competent of PET/CT was assessed by comparing with the clinical findings. Results In total 104 patients, recurrent and(or)metastasis tumors were proved in 52 patients. By the patient-based unit, the sensitivity, specificity,accuracy,positive predictive value and negatice predictive value of PET/CT in detecting recurrent tumor and/or metastasis were 100% , 98. 1% , 99. 0% , 98. 1% and 100 % , respectively. By the lesions-based unit, the sensitivity, specificity, accuracy, positive predictive value and negatice predictive value of PET/CT were 98. 2% , 75

  17. Correction to the count-rate detection limit and sample/blank time-allocation methods

    International Nuclear Information System (INIS)

    Alvarez, Joseph L.

    2013-01-01

    A common form of count-rate detection limits contains a propagation of uncertainty error. This error originated in methods to minimize uncertainty in the subtraction of the blank counts from the gross sample counts by allocation of blank and sample counting times. Correct uncertainty propagation showed that the time allocation equations have no solution. This publication presents the correct form of count-rate detection limits. -- Highlights: •The paper demonstrated a proper method of propagating uncertainty of count rate differences. •The standard count-rate detection limits were in error. •Count-time allocation methods for minimum uncertainty were in error. •The paper presented the correct form of the count-rate detection limit. •The paper discussed the confusion between count-rate uncertainty and count uncertainty

  18. Detection of sentinel lymph node in breast cancer and malignant melanoma - Influence of some factors on detection success rate

    International Nuclear Information System (INIS)

    Krafta, O.; Safarcika, K.; Stepien, A.

    2004-01-01

    Full text: The aim of this study was to compare three radiopharmaceuticals for sentinel lymph node detection in breast cancer and malignant melanoma patients. We examined 100 women and 2 men with breast cancer (average age 59.3 years) and 167 patients with malignant melanoma (69 men with mean age of 58.6 years and 98 women with mean age of 53.6 years). Lymphoscintigraphy was performed in all patients after injection of the radiotracer, either of the three: NANOCIS (average particle size 100 nm), SENTISCINT (particle size 100-600 nm), and NANOCOLL (particle size under 80 nm). Dynamic scintigraphy was performed in melanoma patients while breast cancer patients were subjected to stating imaging at 1-2 and 22 hours of injection. In patients with melanoma surgery was done on the same day, to remove the primary tumor, sentinel lymph node and other nodes, wherever required. In breast cancer patients, surgery, more or less, was done on the second day of radiotracer injection. In operation theatre isosulfan blue dye and gamma probe was used to detect sentinel lymph nodes. In breast cancer patients, scintigraphy detected a total of 231 lymph nodes but failed to show sentinel lymph node in 7 patients (success rate of lymphoscintigraphy 93.1 %). Using gamma probe 158 lymph nodes were detected in 89 patients but sentinel nodes were missed in 9 patients (success rate of probe was 89.9 %). 146 lymph nodes could be visualised using blue dye in 92 patients but were missed in 12 patients (detection rate by dye was 87 %). In 2 patients sentinel lymph node could not be detected by any method. In patients with melanoma, scintigraphy showed 304 lymph nodes. However, it did not detect sentinel lymph node in 9 patients (success rate of lymphoscintigraphy was 94.6 %). 104 patients were examined by means of gamma probe and 132 lymph nodes were detected and no lymph node was found in 13 patients (success rate of probe 87.5%). Using blue dye in 140 patients, 131 nodes were found but were

  19. The efficacy of preoperative positron emission tomography-computed tomography (PET-CT) for detection of lymph node metastasis in cervical and endometrial cancer: clinical and pathological factors influencing it.

    Science.gov (United States)

    Nogami, Yuya; Banno, Kouji; Irie, Haruko; Iida, Miho; Kisu, Iori; Masugi, Yohei; Tanaka, Kyoko; Tominaga, Eiichiro; Okuda, Shigeo; Murakami, Koji; Aoki, Daisuke

    2015-01-01

    We studied the diagnostic performance of (18)F-fluoro-2-deoxy-d-glucose-positron emission tomography/computed tomography in cervical and endometrial cancers with particular focus on lymph node metastases. Seventy patients with cervical cancer and 53 with endometrial cancer were imaged with (18)F-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography before lymphadenectomy. We evaluated the diagnostic performance of (18)F-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography using the final pathological diagnoses as the golden standard. We calculated the sensitivity, specificity, positive predictive value and negative predictive value of (18)F-fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography. In cervical cancer, the results evaluated by cases were 33.3, 92.7, 55.6 and 83.6%, respectively. When evaluated by the area of lymph nodes, the results were 30.6, 98.9, 55.0 and 97.0%, respectively. As for endometrial cancer, the results evaluated by cases were 50.0, 93.9, 40.0 and 95.8%, and by area of lymph nodes, 45.0, 99.4, 64.3 and 98.5%, respectively. The limitation of the efficacy was found out by analyzing it by the region of the lymph node, the size of metastatic node, the historical type of tumor in cervical cancer and the prevalence of lymph node metastasis. The efficacy of positron emission tomography/computed tomography regarding the detection of lymph node metastasis in cervical and endometrial cancer is not established and has limitations associated with the region of the lymph node, the size of metastasis lesion in lymph node and the pathological type of primary tumor. The indication for the imaging and the interpretation of the results requires consideration for each case by the pretest probability based on the information obtained preoperatively. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Staging Lung Cancer: Metastasis.

    Science.gov (United States)

    Shroff, Girish S; Viswanathan, Chitra; Carter, Brett W; Benveniste, Marcelo F; Truong, Mylene T; Sabloff, Bradley S

    2018-05-01

    The updated eighth edition of the tumor, node, metastasis (TNM) classification for lung cancer includes revisions to T and M descriptors. In terms of the M descriptor, the classification of intrathoracic metastatic disease as M1a is unchanged from TNM-7. Extrathoracic metastatic disease, which was classified as M1b in TNM-7, is now subdivided into M1b (single metastasis, single organ) and M1c (multiple metastases in one or multiple organs) descriptors. In this article, the rationale for changes in the M descriptors, the utility of preoperative staging with PET/computed tomography, and the treatment options available for patients with oligometastatic disease are discussed. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Research Progress of Lung Cancer with Leptomeningeal Metastasis

    Directory of Open Access Journals (Sweden)

    Chunhua MA

    2014-09-01

    Full Text Available Leptomeningeal metastases is one of the most serious complications of lung cancer, the patients with poor prognosis. Leptomeningeal metastasis in patients with lack specificity of clinical manifestations. The main clinical performance are the damage of cerebral symptoms, cranial nerve and spinal nerve. The diagnosis primarily based on the history of tumor, clinical symptoms, enhance magnetic resnance image (MRI scan and cerebrospinal fluid cytology. In recent years, new ways of detecting clinically, significantly increase the rate of early detection of leptomeningeal metastases. The effect of comprehensive treatments are still sad. The paper make a review of research progress in pathologic physiology, clinical manifestations, diagnosis methods and treatments of lung cancer with leptomeningeal metastases.

  2. Is there a requirement for axillary lymph node dissection following identification of micro-metastasis or isolated tumour cells at sentinel node biopsy for breast cancer?

    LENUS (Irish Health Repository)

    Joyce, D P

    2012-02-29

    INTRODUCTION: Recent decades have seen a significant shift towards conservative management of the axilla. Increasingly, immunohistochemical analysis of sentinel nodes leads to the detection of small tumour deposits, the significance of which remains uncertain. The aims of this study are to examine patients whose sentinel lymph nodes are positive for macro-metastasis, micro-metastasis or isolated tumour cells (ITCs) and to determine the rate of further nodal disease after axillary lymph node dissection (ALND). METHODS: A retrospective analysis of all patients undergoing a sentinel lymph node biopsy (SLNB) between January 2007 and December 2010 in a tertiary referral breast unit was performed. Patients who underwent an axillary lymph node dissection for macro-metastasis, micro-metastasis or ITCs were identified. Demographics, histological data and the rate of further axillary disease were examined. RESULTS: In total, 664 breast cancer patients attended the symptomatic breast unit during the study period, 360 of whom underwent a SLNB. Seventy patients had a SLNB positive for macro-metastasis. All of these patients underwent ALND. A positive SLNB with either micro-metastasis or ITCs was identified in 58 patients. Only 41 of the 58 patients went on to have an ALND, due primarily to variations in surgeons\\' preferences. Nineteen patients with micro-metastasis underwent an ALND. Four patients had further axillary disease (21%). Twenty-two patients had ITCs identified, of whom only one had further disease (4.5%). No statistically significant difference was found between the two groups in terms of tumour size, grade, lymphovascular invasion or oestrogen receptor status. CONCLUSION: ALND should be considered in patients with micro-metastasis at SLNB. It should rarely be employed in the setting of SLNB positive for ITCs.

  3. Brain metastasis from colorectal cancer

    International Nuclear Information System (INIS)

    Bamba, Yoshiko; Itabashi, Michio; Hirosawa, Tomoichiro; Ogawa, Shinpei; Noguchi, Eiichiro; Takemoto, Kaori; Shirotani, Noriyasu; Kameoka, Shingo

    2007-01-01

    The present study was performed to clarify the clinical characteristics of brain metastasis from colorectal cancer. Five patients with brain metastasis from colorectal cancer treated at our institute between 2001 and 2005 were included in the study. Clinical findings and survival time were determined and an appropriate system for follow-up in such cases was considered. Brain metastasis was found after surgery for colorectal cancer in 4 cases. In addition, colorectal cancer was found after diagnosis of brain metastasis in 1 case. At the time of diagnosis of brain metastasis, all patients had lung metastasis and 3 had liver metastasis. The mean periods between surgery for colorectal cancer and lung and brain metastases were 19.5 and 38.2 months, respectively. In all cases, brain metastasis was diagnosed by imaging after the appearance of neurological symptoms. Brain metastases were multiple in 1 case and focal in 4 cases. We performed gamma knife radiation therapy, and the symptoms disappeared or decreased in all cases. Mean survival time after brain metastasis was 3.0 months. Prognosis after brain metastasis is poor, but gamma knife radiation therapy contributed to patients' quality of life. (author)

  4. Gastric metastasis of triple negative invasive lobular carcinoma

    OpenAIRE

    Caglayan Geredeli; Osman Dogru; Ethem Omeroglu; Farise Yilmaz; Faruk Cicekci

    2015-01-01

    Invasive lobular carcinomas are the second most common type (5% to 15%) of invasive breast carcinomas. The most frequent sites of breast cancer metastasis are the local and distant lymph nodes, brain, lung, liver, and bones; metastasis to the gastrointestinal system, especially to the stomach, is rare. When a mass is detected in an unusual place in a patient with invasive lobular carcinoma, it should be kept in mind that such a mass may be either a second primary carcinoma or the metastasis o...

  5. A Compound Detection System Based on Ultrasonic Flow Rate and Concentration

    Directory of Open Access Journals (Sweden)

    Qing-Hui WANG

    2014-02-01

    Full Text Available This paper proposes a new detection system for monitoring gas concentration and flow rate. Velocity difference of ultrasonic wave in bi-directional propagation in measured gas is recorded and utilized for computing the online gas concentration and flow rate. Meanwhile, the temperature compensation, return signal processing and error analysis algorithms are applied to improve the accuracy. The experimental results show that, compared with the single sensor measurement of gas flow rate or concentration, the proposed detection system with lower cost and higher accuracy can be applied in the occasion which needs simultaneous monitoring of gas concentration and flow rate.

  6. Time-Frequency Analysis of Terahertz Radar Signals for Rapid Heart and Breath Rate Detection

    National Research Council Canada - National Science Library

    Massar, Melody L

    2008-01-01

    We develop new time-frequency analytic techniques which facilitate the detection of a person's heart and breath rates from the Doppler shift the movement of their body induces in a terahertz radar signal...

  7. Tongue metastasis mimicking an abscess.

    Science.gov (United States)

    Mavili, Ertuğrul; Oztürk, Mustafa; Yücel, Tuba; Yüce, Imdat; Cağli, Sedat

    2010-03-01

    Primary tumors metastasizing to the oral cavity are extremely rare. Lung is one of the most common primary sources of metastases to the tongue. Although the incidence of lung cancer is increasing, tongue metastasis as the initial presentation of the tumor remains uncommon. Due to the rarity of tongue metastasis, little is known about its imaging findings. Herein we report the magnetic resonance imaging and clinical findings of a lingual metastasis, mimicking an abscess, from a primary lung cancer.

  8. Adaptive heart rate-based epileptic seizure detection using real-time user feedback

    DEFF Research Database (Denmark)

    De Cooman, Thomas; Kjær, Troels Wesenberg; Van Huffel, Sabine

    2017-01-01

    Automated seizure detection in a home environment has been of increased interest the last couple of decades. Heart rate-based seizure detection is a way to detect temporal lobe epilepsy seizures at home, but patient-independent algorithms showed to be insufficiently accurate due to the high patient...... with incorrect user feedback, making it ideal for implementation in a home environment for a seizure warning system....

  9. Evaluation of Bone Metastasis from Hepatocellular Carcinoma Using 18F FDG PET/CT and 99mTc HDP Bone Scintigraphy: Characteristics of Soft Tissue Formation

    International Nuclear Information System (INIS)

    Seo, Hyo Jung; Choi, Yun Jung; Kim, Hyun Jeong; Jeong, Youg Hyu; Cho, Arthur; Lee, Jae Hoon; Yun, Mijin; Choi, Hye Jin; Lee, Jong Doo; Kang, Won Jun

    2011-01-01

    Bone metastasis from hepatocellular carcinoma (HCC) can present with soft tissue formation, resulting in oncologic emergency. Contrast enhanced FDG PET/CT and bone scintigraphy were compared to evaluate characteristics of bone metastases with of without soft tissue formation from HCC. of 4,151 patients with HCC, 263 patients had bone metastases. Eighty five patients with bone metastasis from HCC underwent contrast enhanced FDG PET/CT. Fifty four of the enrolled subjects had recent 99mT c HDP bone scintigraphy available for comparison. Metastatic bone lesions were identified with visual inspection on FDG PET/CT, and maximum standardized uptake value (SUVmax) was used for the quantitative analysis. Confirmation of bone metastasis was based on histopathology, combined imaging modalities, or serial follow up studies. Forty seven patients (55%) presented with soft tissue formation, while the remaining 38 patients presented without soft tissue formation. Frequent sites of bone metastases from HCC were the spine (39%), pelvis (19%), and rib cage (14%). The soft tissue formation group had more frequent bone pain (77 vs. 37%, p<0.0001), higher SUVmax (6.02 vs. 3.52, p<0.007), and higher incidence of photon defect in bone scintigraphy (75 vs. 0%) compared to the non soft tissue formation group. FDG PET/CT had higher detection rate for bone metastasis than bone scintigraphy both in lesion based analysis (98 vs. 53%, p=0.0015) and in patient based analysis (100 vs. 80%, p<0.001). Bone metastasis from HCC showed a high incidence of soft tissue formation requiring emergency treatment. Although the characteristic findings for soft tissue formation such as photon defect in bone scintigraphy are helpful in detection, overall detectability of bone metastasis is higher in FDG PET/CT. Contrast enhanced PET/CT will be useful in finding and delineating soft tissue forming bone metastasis from HCC.

  10. Minimum Symbol Error Rate Detection in Single-Input Multiple-Output Channels with Markov Noise

    DEFF Research Database (Denmark)

    Christensen, Lars P.B.

    2005-01-01

    Minimum symbol error rate detection in Single-Input Multiple- Output(SIMO) channels with Markov noise is presented. The special case of zero-mean Gauss-Markov noise is examined closer as it only requires knowledge of the second-order moments. In this special case, it is shown that optimal detection...

  11. Correlation of NF-κB signal pathway with tumor metastasis of human head and neck squamous cell carcinoma

    International Nuclear Information System (INIS)

    Yan, Ming; Xu, Qin; Zhang, Ping; Zhou, Xiao-jian; Zhang, Zhi-yuan; Chen, Wan-tao

    2010-01-01

    Nuclear factor-kappa B (NF-κB) signaling constitutes a key event in the multistep process of carcinogenesis, progression and treatment in many cancer types. However, the significance of NF-κB pathway for complex and tissue-specific aspects of head and neck cancer progression, such as invasion and metastasis, is less understood. The expression of NF-κB p65 in squamous cell carcinoma of the head and neck (SCCHN) clinical specimens by immunohistochemistry. The role of NF-κB activity in head and neck squamous cell carcinoma was determined by western blot, reporter assay and EMSA analysis in vitro and metastasis assays in vivo in different metastatic potential tumor cells. Furthermore, the apoptosis rate and expression of metastasis-related protein such as MMP9 and VEGF were examined by Annexin V/PI staining and Western blot, respectively. A higher level of active nuclear-localized NF-κB was observed in the metastatic SCCHN specimens group (p < 0.01). The NF-κB activities of SCCHN cell lines with different metastatic potentials were then determined and in excellent agreement with results found in SCCHN specimens, highly metastatic SCCHN cell lines expressed high level of NF-κB activity. The treatment of highly metastatic SCCHN cells with NF-κB inhibitors reduced the in vitro cell invasion capacity of the cells without affecting the apoptotic rate. Additionally, the NF-κB inhibitors significantly inhibited the experimental lung metastasis of Tb cells and lymph node metastasis of TL cells in nude mice. Furthermore, the expression of metastasis-related proteins, such as matrix metalloproteinase 9 and vascular endothelial growth factor, was inhibited by pyrrolidine dithiocarbonate. This study suggests that NF-κB activity significantly contributes to tumor hematologic and lymphatic metastases and may aid in the development of early detection methods or therapies targeting non-conventional molecular targets

  12. The Detection and Correction of Bias in Student Ratings of Instruction.

    Science.gov (United States)

    Haladyna, Thomas; Hess, Robert K.

    1994-01-01

    A Rasch model was used to detect and correct bias in Likert rating scales used to assess student perceptions of college teaching, using a database of ratings. Statistical corrections were significant, supporting the model's potential utility. Recommendations are made for a theoretical rationale and further research on the model. (Author/MSE)

  13. Ten-year detection rate of brain arteriovenous malformations in a large, multiethnic, defined population.

    Science.gov (United States)

    Gabriel, Rodney A; Kim, Helen; Sidney, Stephen; McCulloch, Charles E; Singh, Vineeta; Johnston, S Claiborne; Ko, Nerissa U; Achrol, Achal S; Zaroff, Jonathan G; Young, William L

    2010-01-01

    To evaluate whether increased neuroimaging use is associated with increased brain arteriovenous malformation (BAVM) detection, we examined detection rates in the Kaiser Permanente Medical Care Program of northern California between 1995 and 2004. We reviewed medical records, radiology reports, and administrative databases to identify BAVMs, intracranial aneurysms (IAs: subarachnoid hemorrhage [SAH] and unruptured aneurysms), and other vascular malformations (OVMs: dural fistulas, cavernous malformations, Vein of Galen malformations, and venous malformations). Poisson regression (with robust standard errors) was used to test for trend. Random-effects meta-analysis generated a pooled measure of BAVM detection rate from 6 studies. We identified 401 BAVMs (197 ruptured, 204 unruptured), 570 OVMs, and 2892 IAs (2079 SAHs and 813 unruptured IAs). Detection rates per 100 000 person-years were 1.4 (95% CI, 1.3 to 1.6) for BAVMs, 2.0 (95% CI, 1.8 to 2.3) for OVMs, and 10.3 (95% CI, 9.9 to 10.7) for IAs. Neuroimaging utilization increased 12% per year during the time period (PIAs (PIAs (P4) per 100 000 person-years, without heterogeneity between studies (P=0.25). Rates for BAVMs, OVMs, and IAs in this large, multiethnic population were similar to those in other series. During 1995 to 2004, a period of increasing neuroimaging utilization, we did not observe an increased rate of detection of unruptured BAVMs, despite increased detection of unruptured IAs.

  14. A Compound Detection System Based on Ultrasonic Flow Rate and Concentration

    OpenAIRE

    Qing-Hui WANG; Fang MU; Li-Feng WEI

    2014-01-01

    This paper proposes a new detection system for monitoring gas concentration and flow rate. Velocity difference of ultrasonic wave in bi-directional propagation in measured gas is recorded and utilized for computing the online gas concentration and flow rate. Meanwhile, the temperature compensation, return signal processing and error analysis algorithms are applied to improve the accuracy. The experimental results show that, compared with the single sensor measurement of gas flow rate or conce...

  15. Link Between RI-ISI and Inspection Qualification: Relationship between Defect Detection Rate and Margin of Detection

    International Nuclear Information System (INIS)

    Shepherd, Barrie; Goujon, Sophie; Whittle, John

    2007-01-01

    Quantitative risk-informed in-service inspection (RI-ISI) requires a quantitative measurement of inspection effectiveness if the risk change associated with an inspection is to be determined. Knowing the probability of detection (POD) as a function of defect depth (through wall dimension) would provide ideal information. However the main in-service inspection method for nuclear plant is ultrasonics, for which defect detection capability depends on a wide variety of parameters besides defect depth, such as defect orientation, roughness, location, shape etc. In recognition of this the European approach to inspection qualification is generally based on some combination of technical justification, and practical trials on a relatively limited number of defects. This inspection qualification process involves demonstrating that defects of concern will generate responses in excess of the specified recording level or noise, depending on the inspection. It is not currently designed to quantify the probability with which defects will be detected. The work described in this report has been performed in order to help address the problem of how the information generated during inspection qualification can be used as an input for RI-ISI. The approach adopted has been to recognise that as the defect response increases above the recording or noise level, the probability of detecting defects is likely to increase. The work therefore involved an investigation of the relationship between POD (strictly speaking defect detection rate) and margin of detection. It involved blind manual and automated ultrasonic trials on artificial defects in test plates designed to generate a range of signal responses. The detection rate for defects which provided signals at a particular level above noise or above a recording level was then measured. A relationship between defect detection rate and margin of detection has been established based on these trials. In addition to establishing a stronger link

  16. Vulvar Metastasis from Bladder Cancer

    Directory of Open Access Journals (Sweden)

    Fouad Aoun

    2015-01-01

    Full Text Available Vulvar metastasis of urothelial carcinoma of the bladder is a very rare entity; few cases are reported in the English literature. In this paper, we describe the clinical and pathological characteristics, evolution, and treatment of a patient with vulvar metastasis of urothelial carcinoma of the bladder followed by a brief review of the reported cases in the literature.

  17. Hidradenocarcinoma of the Scrotum with Lymph Node Metastasis

    OpenAIRE

    Maria Inês Simões; Isabel Marcão; Mário Toscano; Luís Borges

    2018-01-01

    Hidradenocarcinoma is a rare neoplasm of the eccrine cells of the sweat glands, usually asymptomatic with slow growing and higher incidence between 50 and 80 years, occurring in both sexes and preferentially located in the palmar, plantar, frontal, axillary and nuchal regions. It has an aggressive behavior, with high rate of local recurrence and distance metastasis, associated with a poor prognosis. We present a case of hidradenocarcinoma of the scrotum manifested by lymph node metastasis thr...

  18. Inhibitory effects of silibinin on proliferation and lung metastasis of human high metastasis cell line of salivary gland adenoid cystic carcinoma via autophagy induction

    Directory of Open Access Journals (Sweden)

    Jiang C

    2016-10-01

    Full Text Available Canhua Jiang,1 Shufang Jin,1 Zhisheng Jiang,1 Jie Wang2 1Department of Oral and Maxillofacial Surgery, Xiangya Hospital, 2Department of Immunology, Xiangya School of Medicine, Central South University, Changsha, Hunan, People’s Republic of China Objective: To investigate the possible mechanisms and effects of silibinin (SIL on the proliferation and lung metastasis of human lung high metastasis cell line of salivary gland adenoid cystic carcinoma (ACC-M.Methods: A methyl thiazolyl tetrazolium assay was performed to detect the inhibitory effects of SIL on the proliferation of ACC-M cells in vitro. Fluorescence microscopy and transmission electron microscopy were used to observe the autophagic process. Western blot was performed to detect the expression of microtube-related protein 1 light-chain 3 (LC3. An experimental adenoid cystic carcinoma (ACC lung metastasis model was established in nude mice to detect the impacts of SIL on lung weight and lung cancer nodules. Immunohistochemistry was used to detect the expressions of LC3 in human ACC samples and normal salivary gland tissue samples.Results: SIL inhibited the proliferation of ACC-M cells in a dose- and time-dependent manner, and inductively increased the autophagic bodies in ACC-M cells. Furthermore, SIL could increase the expression of LC3 in ACC-M cells and promote the conversion of LC3-I into LC3-II in a dose- and time-dependent manner. In the ACC lung metastasis model, the lung weight and left and right lung nodules in the SIL-treated group were significantly less than those in the control group (P<0.05. The expressions of LC3-I and LC3-II as well as the positive expression rate of LC3 (80% significantly increased, but the positive expression of LC3 in human ACC (42.22% reduced significantly.Conclusion: SIL could inhibit the proliferation and lung metastasis of ACC-M cells by possibly inducing tumor cells autophagy. Keywords: silibinin, adenoid cystic carcinoma, ACC-M cells, autophagy

  19. Hypoxia-induced metastasis model in embryonic zebrafish

    DEFF Research Database (Denmark)

    Rouhi, Pegah; Jensen, Lasse D.; Cao, Ziquan

    2010-01-01

    Hypoxia facilitates tumor invasion and metastasis by promoting neovascularization and co-option of tumor cells in the peritumoral vasculature, leading to dissemination of tumor cells into the circulation. However, until recently, animal models and imaging technology did not enable monitoring...... of the early events of tumor cell invasion and dissemination in living animals. We recently developed a zebrafish metastasis model to dissect the detailed events of hypoxia-induced tumor cell invasion and metastasis in association with angiogenesis at the single-cell level. In this model, fluorescent Di......I-labeled human or mouse tumor cells are implanted into the perivitelline cavity of 48-h-old zebrafish embryos, which are subsequently placed in hypoxic water for 3 d. Tumor cell invasion, metastasis and pathological angiogenesis are detected under fluorescent microscopy in the living fish. The average...

  20. Iris metastasis of gastric adenocarcinoma.

    Science.gov (United States)

    Celebi, Ali Riza Cenk; Kilavuzoglu, Ayse Ebru; Altiparmak, U Emrah; Cosar, C Banu; Ozkiris, Abdullah

    2016-03-08

    Iris metastasis in patients with gastric cancer is extremely rare. Herein, it is aimed to report on a patient with gastric adenocarcinoma and iris metastasis. A 65-year-old patient with the history of gastric cancer was admitted for eye pain and eye redness on his left eye. There was ciliary injection, severe +4 cells with hypopyon in the anterior chamber and a solitary, friable, yellow-white, fleshy-creamy vascularized 2 mm × 4 mm mass on the upper nasal part of the iris within the left eye. The presented patient's mass lesion in the iris fulfilled the criteria of the metastatic iris lesion's appearance. The ocular metastasis occurred during chemotherapy. Iris metastasis can masquerade as iridocyclitis with pseudohypopyon or glaucoma. In patients with a history of gastric cancer that present with an iris mass, uveitis, and high intraocular pressure, ocular metastasis of gastric cancer should be a consideration.

  1. Cost and detection rate of glaucoma screening with imaging devices in a primary care center

    Directory of Open Access Journals (Sweden)

    Anton A

    2017-02-01

    Full Text Available Alfonso Anton,1–4 Monica Fallon,3,5 Francesc Cots,2 María A Sebastian,6 Antonio Morilla-Grasa,4 Sergi Mojal,3 Xavier Castells2 1Medicine School, Universidad Internacional de Cataluña, 2Servei d’Estudies, Parc de Salut Mar, 3Instituto Hospital del Mar de Investigaciones Médicas (IMIM, 4Glaucoma Department, Instituto Catalán de Retina (ICR, 5Universidad Autónoma de Barcelona, 6Centro de Atención Primaria Larrard, Barcelona, Spain Purpose: To analyze the cost and detection rate of a screening program for detecting glaucoma with imaging devices. Materials and methods: In this cross-sectional study, a glaucoma screening program was applied in a population-based sample randomly selected from a population of 23,527. Screening targeted the population at risk of glaucoma. Examinations included optic disk tomography (Heidelberg retina tomograph [HRT], nerve fiber analysis, and tonometry. Subjects who met at least 2 of 3 endpoints (HRT outside normal limits, nerve fiber index ≥30, or tonometry ≥21 mmHg were referred for glaucoma consultation. The currently established (“conventional” detection method was evaluated by recording data from primary care and ophthalmic consultations in the same population. The direct costs of screening and conventional detection were calculated by adding the unit costs generated during the diagnostic process. The detection rate of new glaucoma cases was assessed. Results: The screening program evaluated 414 subjects; 32 cases were referred for glaucoma consultation, 7 had glaucoma, and 10 had probable glaucoma. The current detection method assessed 677 glaucoma suspects in the population, of whom 29 were diagnosed with glaucoma or probable glaucoma. Glaucoma screening and the conventional detection method had detection rates of 4.1% and 3.1%, respectively, and the cost per case detected was 1,410 and 1,435€, respectively. The cost of screening 1 million inhabitants would be 5.1 million euros and would allow

  2. Prospective Comparison of F-18 Choline PET/CT Scan Versus Axial MRI for Detecting Bone Metastasis in Biochemically Relapsed Prostate Cancer Patients

    Directory of Open Access Journals (Sweden)

    Wouter Huysse

    2017-10-01

    Full Text Available We compared fluor-18 choline positron emission tomography/computed tomography (PET/CT and axial skeleton magnetic resonance imaging (MRI prospectively obtained for the detection of bone metastases in non-castrated patients with biochemically recurrent prostate cancer following primary treatment. PET/CT was performed 45 min post-injection of 3–4 MBq/kg F-18 methyl choline. MRI included T1- and fluid sensitive T2-weighted images of the spine and pelvis. Readers were initially blinded from other results and all scans underwent independent double reading. The best valuable comparator (BVC defined the metastatic status. On the basis of the BVC, 15 out of 64 patients presented with 24 bone metastases. On a patient level, the sensitivity and specificity of MRI and PET were not significantly different. On a lesion level, the sensitivity of MRI was significantly better compared to PET, and the specificity did not differ significantly. In conclusion, axial MRI is an interesting screening tool for the detection of bone metastases because of its low probability of false negative results. However, F-18 choline PET is a valuable addition as it can overrule false positive MRI results and detect non-axial metastases.

  3. Novel Fingertip Image-Based Heart Rate Detection Methods for a Smartphone

    Directory of Open Access Journals (Sweden)

    Rifat Zaman

    2017-02-01

    Full Text Available We hypothesize that our fingertip image-based heart rate detection methods using smartphone reliably detect the heart rhythm and rate of subjects. We propose fingertip curve line movement-based and fingertip image intensity-based detection methods, which both use the movement of successive fingertip images obtained from smartphone cameras. To investigate the performance of the proposed methods, heart rhythm and rate of the proposed methods are compared to those of the conventional method, which is based on average image pixel intensity. Using a smartphone, we collected 120 s pulsatile time series data from each recruited subject. The results show that the proposed fingertip curve line movement-based method detects heart rate with a maximum deviation of 0.0832 Hz and 0.124 Hz using time- and frequency-domain based estimation, respectively, compared to the conventional method. Moreover, another proposed fingertip image intensity-based method detects heart rate with a maximum deviation of 0.125 Hz and 0.03 Hz using time- and frequency-based estimation, respectively.

  4. [Neck lymphatic metastasis, surgical methods and prognosis in early tongue squamous cell carcinoma].

    Science.gov (United States)

    Wang, L S; Zhou, F T; Han, C B; He, X P; Zhang, Z X

    2018-02-09

    Objective: To investigate the different pattern of neck lymph node metastasis, the choice of surgical methods and prognosis in early tongue squamous cell carcinoma. Methods: A total of 157 patients with early oral tongue squamous cell carcinoma were included in this study. Statistical analysis was performed to identify the pattern of lymph node metastasis, to determine the best surgical procedure and to analyze the prognosis. Results: The occurrence of cervical lymph node metastasis rate was 31%(48/157). Neck lymphatic metastasis was significantly related to tumor size ( P= 0.026) and histology differentiation type ( P= 0.022). The rate of metastasis was highest in level Ⅱ [33% (16/48)]. In level Ⅳ, the incidence of lymph node metastasis was 5%(7/157), and there was no skip metastases. The possibility of level Ⅳ metastasis was higher, when level Ⅱ ( P= 0.000) or Ⅲ ( P= 0.000) involved. The differentiation tumor recurrence, neck lymphatic metastasis and adjuvant radiotherapy were prognostic factors ( Psquamous cell carcinoma, simultaneous glossectomy and neck dissection should be performed. Level Ⅳ metastasis rate is extremely low, so supraomohyoid neck dissection is sufficient for most of the time. The histology differentiation type, neck lymphatic metastasis and adjuvant radiotherapy are independent prognostic factors.

  5. Prostate-specific antigen nadir within 12 months as an early surrogate marker of biochemical failure and distant metastasis after low-dose-rate brachytherapy or external beam radiotherapy for localized prostate cancer.

    Science.gov (United States)

    Nishimura, Shuichi; Ohashi, Toshio; Momma, Tetsuo; Sakayori, Masanori; Eriguchi, Takahisa; Tanaka, Tomoki; Yamashita, Shoji; Kosaka, Takeo; Oya, Mototsugu; Shigematsu, Naoyuki

    2018-05-01

    Prostate-specific antigen nadir (nPSA) after radiotherapy for localized prostate cancer has been investigated as a predictor. However, nPSA usually requires several years, limiting its clinical utility. We investigated the significance of nPSA within 12 months (nPSA12) after low-dose-rate prostate brachytherapy (LDR-PB) or external beam radiotherapy (EBRT) on treatment outcomes. Between 2006 and 2014, 663 patients with prostate cancer were treated with LDR-PB or EBRT at two institutions. Four hundred and seventy-four men received LDR-PB and 189 men received EBRT, without androgen deprivation therapy. The Kaplan-Meier method was used for biochemical failure (BF)-free survival (BFFS) and distant metastasis (DM)-free survival (DMFS) analyses, and multivariable Cox regression analysis was performed. The median follow-up was 61.3 months. The median nPSA12 in the LDR-PB and EBRT cohorts was 0.7 and 1.0 ng/mL, respectively. The 7-year BFFS and DMFS rates in LDR-PB patients with nPSA12 ≤ 0.7 ng/mL were 99.1% and 99.5%, respectively; when nPSA12 was >0.7 ng/mL, they were 90.2% and 94.8%, respectively. In EBRT patients with nPSA12 ≤ 1.0 ng/mL, BFFS and DMFS rates were 85.4% and 98.5%, respectively; when nPSA12 was >1.0 ng/mL, they were 67.1% and 87.2%, respectively. nPSA12 was an independent predictor of BF and DM in both cohorts (LDR-PB, P = 0.004 and 0.020, respectively; EBRT, P = 0.005 and 0.041, respectively). The nPSA12 after LDR-PB or EBRT is significantly associated with treatment outcomes of prostate cancer. Higher nPSA12 may identify patients at high risk of relapse who might benefit from salvage treatment. © 2018 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  6. Technological advances for improving adenoma detection rates: The changing face of colonoscopy.

    Science.gov (United States)

    Ishaq, Sauid; Siau, Keith; Harrison, Elizabeth; Tontini, Gian Eugenio; Hoffman, Arthur; Gross, Seth; Kiesslich, Ralf; Neumann, Helmut

    2017-07-01

    Worldwide, colorectal cancer is the third commonest cancer. Over 90% follow an adenoma-to-cancer sequence over many years. Colonoscopy is the gold standard method for cancer screening and early adenoma detection. However, considerable variation exists between endoscopists' detection rates. This review considers the effects of different endoscopic techniques on adenoma detection. Two areas of technological interest were considered: (1) optical technologies and (2) mechanical technologies. Optical solutions, including FICE, NBI, i-SCAN and high definition colonoscopy showed mixed results. In contrast, mechanical advances, such as cap-assisted colonoscopy, FUSE, EndoCuff and G-EYE™, showed promise, with reported detections rates of up to 69%. However, before definitive recommendations can be made for their incorporation into daily practice, further studies and comparison trials are required. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  7. LASER: A Maximum Likelihood Toolkit for Detecting Temporal Shifts in Diversification Rates From Molecular Phylogenies

    Directory of Open Access Journals (Sweden)

    Daniel L. Rabosky

    2006-01-01

    Full Text Available Rates of species origination and extinction can vary over time during evolutionary radiations, and it is possible to reconstruct the history of diversification using molecular phylogenies of extant taxa only. Maximum likelihood methods provide a useful framework for inferring temporal variation in diversification rates. LASER is a package for the R programming environment that implements maximum likelihood methods based on the birth-death process to test whether diversification rates have changed over time. LASER contrasts the likelihood of phylogenetic data under models where diversification rates have changed over time to alternative models where rates have remained constant over time. Major strengths of the package include the ability to detect temporal increases in diversification rates and the inference of diversification parameters under multiple rate-variable models of diversification. The program and associated documentation are freely available from the R package archive at http://cran.r-project.org.

  8. Shilling attack detection for recommender systems based on credibility of group users and rating time series.

    Science.gov (United States)

    Zhou, Wei; Wen, Junhao; Qu, Qiang; Zeng, Jun; Cheng, Tian

    2018-01-01

    Recommender systems are vulnerable to shilling attacks. Forged user-generated content data, such as user ratings and reviews, are used by attackers to manipulate recommendation rankings. Shilling attack detection in recommender systems is of great significance to maintain the fairness and sustainability of recommender systems. The current studies have problems in terms of the poor universality of algorithms, difficulty in selection of user profile attributes, and lack of an optimization mechanism. In this paper, a shilling behaviour detection structure based on abnormal group user findings and rating time series analysis is proposed. This paper adds to the current understanding in the field by studying the credibility evaluation model in-depth based on the rating prediction model to derive proximity-based predictions. A method for detecting suspicious ratings based on suspicious time windows and target item analysis is proposed. Suspicious rating time segments are determined by constructing a time series, and data streams of the rating items are examined and suspicious rating segments are checked. To analyse features of shilling attacks by a group user's credibility, an abnormal group user discovery method based on time series and time window is proposed. Standard testing datasets are used to verify the effect of the proposed method.

  9. Interference of detection rate of lumbar disc herniation by socioeconomic status.

    Science.gov (United States)

    Ji, Gyu Yeul; Oh, Chang Hyun; Jung, Nak-Yong; An, Seong Dae; Choi, Won-Seok; Kim, Jung Hoon

    2013-03-01

    Retrospective study. The objective of the study is to evaluate the relationship between the detection rate of lumbar disc herniation and socioeconomic status. Income is one important determinant of public health. Yet, there are no reports about the relationship between socioeconomic status and the detective rate of disc herniation. In this study, 443 cases were checked for lumbar computed tomography for lumbar disc herniation, and they reviewed questionnaires about their socioeconomic status, the presence of back pain or radiating pain and the presence of a medical certificate (to check the medical or surgical treatment for the pain) during the Korean conscription. Without the consideration for the presence of a medical certificate, there was no difference in spinal physical grade according to socioeconomic status (p=0.290). But, with the consideration of the presence of a medical certificate, the significant statistical differences were observed according to socioeconomic status in 249 cases in the presence of a medical certificate (p=0.028). There was a lower detection rate in low economic status individuals than those in the high economic class. The common reason for not submitting a medical certificate is that it is neither necessary for the people of lower socioeconomic status nor is it financially affordable. The prevalence of lumbar disc herniation is not different according to socioeconomic status, but the detective rate was affected by socioeconomic status. Socioeconomic status is an important factor for detecting lumbar disc herniation.

  10. Combined Therapy for Distant Metastasis of Sacral Chordoma

    Directory of Open Access Journals (Sweden)

    Birol Özkal

    2015-01-01

    Full Text Available Chordomas are known as rare primary malign tumours that have formed from primitive notochord remains. Sacral chordomas grow slowly but locally and aggressively. Chordomas are locally invasive and have low tendency to metastasis and have a poor prognosis in long-term follow-up. Metastasis may be seen in a rate of 5–40% of the chordomas. Metastasis of chordomas is common in liver, lung, lymph nodes, peritoneum, and brain. The treatment approaches, including surgery, have been discussed in the literature before. Susceptibility to radiotherapy and chemotherapy is controversial in these tumours. The success of surgical treatment affects survival directly. In this report, we will report a sacral chordoma case in which an intraperitoneal distant metastasis occurred and discuss the surgical approach.

  11. Ampullary carcinoma with cutaneous metastasis

    Directory of Open Access Journals (Sweden)

    I-Ting Liu

    2016-06-01

    Full Text Available Carcinoma of the ampulla of Vater is a rare gastrointestinal tumor. Additionally, cutaneous metastasis from such an internal malignancy is also uncommon. We reported the case of a 55-year-old man afflicted with ampullary carcinoma with cutaneous metastasis. The patient did not undergo the standard Whipple procedure but received chemotherapy due to apparent left neck lymph node metastasis noted by initial PET/CT imaging. The skin metastasis presented as a left neck infiltrating purpuric lesion, which was confirmed by skin biopsy approximately one year after the patient's disease was first diagnosed. Thereafter, the patient received further chemotherapy pursuant to his course of medical management. Skin metastasis usually represents a poor patient prognosis. In these cases, treatment of cutaneous metastasis typically includes systemic chemotherapy and local management such as radiation therapy or tumor excision. And when choosing a chemotherapy regimen for the ampullary cancer, the histological subtypes (intestinal or pancreatobiliary should be comprehensively considered. In our review of the literature, the intestinal type seems to have less distant lymph node metastasis, advanced local invasion, as well as recurrence than pancreatobiliary type of ampullary cancer.

  12. Density and SUV Ratios from PET/CT in the Detection of Mediastinal Lymph Node Metastasis in Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Tingting SHAO

    2015-03-01

    Full Text Available Background and objective Mediastinal involvement in lung cancer is a highly significant prognostic factor for survival, and accurate staging of the mediastinum will correctly identify patients who will benefit the most from surgery. Positron emission tomography/computed tomography (PET/CT has become the standard imaging modality for the staging of patients with lung cancer. The aim of this study is to investigate 18-fluoro-2-deoxy-glucose (18F-FDG PET/CT imaging in the detection of mediastinal disease in lung cancer. Methods A total of 72 patients newly diagnosed with non-small cell lung cancer (NSCLC who underwent preoperative whole-body 18F-FDG PET/CT were retrospectively included. All patients underwent radical surgery and mediastinal lymph node dissection. Mediastinal disease was histologically confirmed in 45 of 413 lymph nodes. PET/CT doctors analyzed patients’ visual images and evaluated lymph node’s short axis, lymph node’s maximum standardized uptake value (SUVmax, node/aorta density ratio, node/aorta SUV ratio, and other parameters using the histopathological results as the reference standard. The optimal cutoff value for each ratio was determined by receiver operator characteristic curve analysis. Results Using a threshold of 0.9 for density ratio and 1.2 for SUV ratio yielded high accuracy for the detection of mediastinal disease. The lymph node’s short axis, lymph node’s SUVmax, density ratio, and SUV ratio of integrated PET/CT for the accuracy of diagnosing mediastinal lymph node was 95.2%. The diagnostic accuracy of mediastinal lymph node with conventional PET/CT was 89.8%, whereas that of PET/CT comprehensive analysis was 90.8%. Conclusion Node/aorta density ratio and SUV ratio may be complimentary to conventional visual interpretation and SUVmax measurement. The use of lymph node’s short axis, lymph node’s SUVmax, and both ratios in combination is better than either conventional PET/CT analysis or PET

  13. Nasopharyngeal carcinoma with pericardial metastasis

    Directory of Open Access Journals (Sweden)

    Shang-Wen Chen

    2011-07-01

    Full Text Available Nasopharyngeal carcinoma (NPC is prevalent in Taiwan and is characterized by a high frequency of nodal metastasis. The most common organs with distal metastases are the bones, lungs, and liver, with extremely rare cases to the pericardium. Herein, we report a rare case with NPC who presented with dyspnea and orthopnea. Serial studies, including pericardial biopsy, revealed NPC with pericardial metastasis and pericardial effusion. The tumor cells of both the original and metastatic tumors were positive for Epstein–Barr virus by in situ hybridization. This is the first histologically confirmed case of NPC with pericardial metastasis.

  14. Factors influencing variation in physician adenoma detection rates: a theory-based approach for performance improvement.

    Science.gov (United States)

    Atkins, Louise; Hunkeler, Enid M; Jensen, Christopher D; Michie, Susan; Lee, Jeffrey K; Doubeni, Chyke A; Zauber, Ann G; Levin, Theodore R; Quinn, Virginia P; Corley, Douglas A

    2016-03-01

    Interventions to improve physician adenoma detection rates for colonoscopy have generally not been successful, and there are little data on the factors contributing to variation that may be appropriate targets for intervention. We sought to identify factors that may influence variation in detection rates by using theory-based tools for understanding behavior. We separately studied gastroenterologists and endoscopy nurses at 3 Kaiser Permanente Northern California medical centers to identify potentially modifiable factors relevant to physician adenoma detection rate variability by using structured group interviews (focus groups) and theory-based tools for understanding behavior and eliciting behavior change: the Capability, Opportunity, and Motivation behavior model; the Theoretical Domains Framework; and the Behavior Change Wheel. Nine factors potentially associated with adenoma detection rate variability were identified, including 6 related to capability (uncertainty about which types of polyps to remove, style of endoscopy team leadership, compromised ability to focus during an examination due to distractions, examination technique during withdrawal, difficulty detecting certain types of adenomas, and examiner fatigue and pain), 2 related to opportunity (perceived pressure due to the number of examinations expected per shift and social pressure to finish examinations before scheduled breaks or the end of a shift), and 1 related to motivation (valuing a meticulous examination as the top priority). Examples of potential intervention strategies are provided. By using theory-based tools, this study identified several novel and potentially modifiable factors relating to capability, opportunity, and motivation that may contribute to adenoma detection rate variability and be appropriate targets for future intervention trials. Copyright © 2016 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.

  15. Direct inference of SNP heterozygosity rates and resolution of LOH detection.

    Directory of Open Access Journals (Sweden)

    Xiaohong Li

    2007-11-01

    Full Text Available Single nucleotide polymorphisms (SNPs have been increasingly utilized to investigate somatic genetic abnormalities in premalignancy and cancer. LOH is a common alteration observed during cancer development, and SNP assays have been used to identify LOH at specific chromosomal regions. The design of such studies requires consideration of the resolution for detecting LOH throughout the genome and identification of the number and location of SNPs required to detect genetic alterations in specific genomic regions. Our study evaluated SNP distribution patterns and used probability models, Monte Carlo simulation, and real human subject genotype data to investigate the relationships between the number of SNPs, SNP HET rates, and the sensitivity (resolution for detecting LOH. We report that variances of SNP heterozygosity rate in dbSNP are high for a large proportion of SNPs. Two statistical methods proposed for directly inferring SNP heterozygosity rates require much smaller sample sizes (intermediate sizes and are feasible for practical use in SNP selection or verification. Using HapMap data, we showed that a region of LOH greater than 200 kb can be reliably detected, with losses smaller than 50 kb having a substantially lower detection probability when using all SNPs currently in the HapMap database. Higher densities of SNPs may exist in certain local chromosomal regions that provide some opportunities for reliably detecting LOH of segment sizes smaller than 50 kb. These results suggest that the interpretation of the results from genome-wide scans for LOH using commercial arrays need to consider the relationships among inter-SNP distance, detection probability, and sample size for a specific study. New experimental designs for LOH studies would also benefit from considering the power of detection and sample sizes required to accomplish the proposed aims.

  16. Prospective study of tailoring whole-body dual-modality [18F]fluorodeoxyglucose positron emission tomography/computed tomography with plasma Epstein-Barr virus DNA for detecting distant metastasis in endemic nasopharyngeal carcinoma at initial staging.

    Science.gov (United States)

    Tang, Lin-Quan; Chen, Qiu-Yan; Fan, Wei; Liu, Huai; Zhang, Lu; Guo, Ling; Luo, Dong-Hua; Huang, Pei-Yu; Zhang, Xu; Lin, Xiao-Ping; Mo, Yun-Xian; Liu, Li-Zhi; Mo, Hao-Yuan; Li, Jian; Zou, Ru-Hai; Cao, Yun; Xiang, Yan-Qun; Qiu, Fang; Sun, Rui; Chen, Ming-Yuan; Hua, Yi-Jun; Lv, Xing; Wang, Lin; Zhao, Chong; Guo, Xiang; Cao, Ka-Jia; Qian, Chao-Nan; Zeng, Mu-Sheng; Mai, Hai-Qiang

    2013-08-10

    To evaluate which patients with nasopharyngeal carcinoma (NPC) obtained the greatest benefits from the detection of distant metastasis with [(18)F]fluorodeoxyglucose positron emission tomography and computed tomography (PET/CT) combined with plasma Epstein-Barr virus (EBV) DNA levels. Consecutive patients with NPC were prospectively enrolled. PET/CT, conventional work-up (CWU), and quantification of plasma EBV DNA were performed before treatment. The accuracy of these strategies for distant metastases was assessed. The costs of the diagnostic strategies were compared. Eighty-six (14.8%) of the 583 eligible patients were found to have distant metastases; 71 patients (82.6%) by PET/CT and 31 patients (36.0%) by CWU. In the multivariable analysis, advanced N stage (odds ratio, 2.689; 95% CI, 1.894 to 3.818) and pretreatment EBV DNA level (odds ratio, 3.344; 95% CI, 1.825 to 6.126) were significant risk factors for distant metastases. PET/CT was not superior to CWU for detecting distant metastases in very low-risk patients (N0-1 with EBV DNA < 4,000 copies/mL; P = .062), but was superior for the low-risk patients (N0-1 with EBV DNA ≥ 4,000 copies/mL and N2-3 with EBV DNA < 4,000 copies/mL; P = .039) and intermediate-risk patients (N2-3 disease with EBV DNA ≥ 4,000 copies/mL; P < .001). The corresponding patient management changes based on PET/CT were 2.9%, 6.3%, and 16.5%, respectively. The costs per true-positive case detected by PET/CT among these groups were ¥324,138 (≈$47,458), ¥96,907 (≈$14,188), and ¥34,182 (≈$5,005), respectively. PET/CT detects more distant metastases than conventional staging in patients with NPC. The largest benefit in terms of cost and patient management was observed in the subgroup with N2-3 disease and EBV DNA ≥ 4,000 copies/mL.

  17. A new semiquantitative method for evaluation of metastasis progression.

    Science.gov (United States)

    Volarevic, A; Ljujic, B; Volarevic, V; Milovanovic, M; Kanjevac, T; Lukic, A; Arsenijevic, N

    2012-01-01

    Although recent technical advancements are directed toward developing novel assays and methods for detection of micro and macro metastasis, there are still no reports of reliable, simple to use imaging software that could be used for the detection and quantification of metastasis in tissue sections. We herein report a new semiquantitative method for evaluation of metastasis progression in a well established 4T1 orthotopic mouse model of breast cancer metastasis. The new semiquantitative method presented here was implemented by using the Autodesk AutoCAD 2012 program, a computer-aided design program used primarily for preparing technical drawings in 2 dimensions. By using the Autodesk AutoCAD 2012 software- aided graphical evaluation we managed to detect each metastatic lesion and we precisely calculated the average percentage of lung and liver tissue parenchyma with metastasis in 4T1 tumor-bearing mice. The data were highly specific and relevant to descriptive histological analysis, confirming reliability and accuracy of the AutoCAD 2012 software as new method for quantification of metastatic lesions. The new semiquantitative method using AutoCAD 2012 software provides a novel approach for the estimation of metastatic progression in histological tissue sections.

  18. Detection and Modeling of Non-Tidal Oceanic Effects on the Earth's Rotation Rate

    Science.gov (United States)

    Marcus, S. L.; Chao, Y.; Dickey, J. O.; Gegout, P.

    1998-01-01

    Sub-decadal changes in the Earth's rotation rate, and hence in the length-of-day (LOD), are largely controlled by variations in atmospheric angular momentum. Results from two oceanic general circulation models (OGCMs), forced by observed wind stress and heat flux for the years 1992-1994, show that ocean current and mass distribution changes also induce detectable LOD variations.

  19. Leadership training to improve adenoma detection rate in screening colonoscopy: A randomised trial

    NARCIS (Netherlands)

    M.F. Kaminski (Michal); J. Anderson (John); R.M. Valori (Roland ); E. Kraszewska (Ewa); M. Rupinski (Maciej); J. Pachlewski (Jacek); E. Wronska (Ewa); M. Bretthauer (Michael); S. Thomas-Gibson (Siwan); E.J. Kuipers (Ernst); J. Regula (J.)

    2016-01-01

    textabstractObjective Suboptimal adenoma detection rate (ADR) at colonoscopy is associated with increased risk of interval colorectal cancer. It is uncertain how ADR might be improved. We compared the effect of leadership training versus feedback only on colonoscopy quality in a countrywide

  20. Low-Rate DDoS Attack Detection Using Expectation of Packet Size

    Directory of Open Access Journals (Sweden)

    Lu Zhou

    2017-01-01

    Full Text Available Low-rate Distributed Denial-of-Service (low-rate DDoS attacks are a new challenge to cyberspace, as the attackers send a large amount of attack packets similar to normal traffic, to throttle legitimate flows. In this paper, we propose a measurement—expectation of packet size—that is based on the distribution difference of the packet size to distinguish two typical low-rate DDoS attacks, the constant attack and the pulsing attack, from legitimate traffic. The experimental results, obtained using a series of real datasets with different times and different tolerance factors, are presented to demonstrate the effectiveness of the proposed measurement. In addition, extensive experiments are performed to show that the proposed measurement can detect the low-rate DDoS attacks not only in the short and long terms but also for low packet rates and high packet rates. Furthermore, the false-negative rates and the adjudication distance can be adjusted based on the detection sensitivity requirements.

  1. A visible light imaging device for cardiac rate detection with reduced effect of body movement

    Science.gov (United States)

    Jiang, Xiaotian; Liu, Ming; Zhao, Yuejin

    2014-09-01

    A visible light imaging system to detect human cardiac rate is proposed in this paper. A color camera and several LEDs, acting as lighting source, were used to avoid the interference of ambient light. From people's forehead, the cardiac rate could be acquired based on photoplethysmography (PPG) theory. The template matching method was used after the capture of video. The video signal was discomposed into three signal channels (RGB) and the region of interest was chosen to take the average gray value. The green channel signal could provide an excellent waveform of pulse wave on the account of green lights' absorptive characteristics of blood. Through the fast Fourier transform, the cardiac rate was exactly achieved. But the research goal was not just to achieve the cardiac rate accurately. With the template matching method, the effects of body movement are reduced to a large extent, therefore the pulse wave can be detected even while people are in the moving state and the waveform is largely optimized. Several experiments are conducted on volunteers, and the results are compared with the ones gained by a finger clamped pulse oximeter. The contrast results between these two ways are exactly agreeable. This method to detect the cardiac rate and the pulse wave largely reduces the effects of body movement and can probably be widely used in the future.

  2. Cutaneous metastasis in anorectal adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Krishnendra Varma

    2015-01-01

    Full Text Available Cutaneous metastasis in anorectal adenocarcinoma is a rare entity. Here, we report the case of a 40-year-old female who presented with yellowish-brown, irregular, solid, elevated rashes over the pubis with a recent history off palliative colostomy for anorectal adenocarcinoma. Clinically, we suspected metastasis that was proved on biopsy. We report this case due to the rare presenting site (i.e., perineum of a metastatic adenocarcinoma.

  3. Detectability of changes in cosmic-ray counting rate measured with the Liulin detector

    International Nuclear Information System (INIS)

    Malusek, A.; Kubancak, J.; Ambrozova, I.

    2011-05-01

    Experimental data are needed to improve and validate models predicting the dynamics of solar particle events because the mechanisms of processes leading to the acceleration of solar energetic particles are not yet fully understood. The aim of this work was to examine whether the spectrometer of deposited energy, Liulin, positioned at the Lomnický štít mountain observatory can collect such data. Decision thresholds and detection limits for the increase or decrease in the average number of particles detected by Liulin were determined for a period in February 2011. The changes in counts corresponding to the decision thresholds and detection limits relative to the average number of detected particles were about 17% and 33%, respectively. The Forbush decrease with a maximum change of about 6.8%, which started on February 18, was detectable neither during the 10-minute acquisition time nor during any other, longer period. Statistical analysis showed that an acquisition time about 7 hours would be needed to detect a 5% decrease. As this time was shorter than the duration of the Forbush decrease (about 56 hours), we theorize that the current placement of the Liulin detector inside a living room shielded by a thick concrete ceiling may have had an adverse impact on the detectability of the the cosmic ray counting rate decrease. To test this hypothesis, we recommend positioning the Liulin detector outside the main observatory building.. (author)

  4. Detecting subsurface fluid leaks in real-time using injection and production rates

    Science.gov (United States)

    Singh, Harpreet; Huerta, Nicolas J.

    2017-12-01

    CO2 injection into geologic formations for either enhanced oil recovery or carbon storage introduces a risk for undesired fluid leakage into overlying groundwater or to the surface. Despite decades of subsurface CO2 production and injection, the technologies and methods for detecting CO2 leaks are still costly and prone to large uncertainties. This is especially true for pressure-based monitoring methods, which require the use of simplified geological and reservoir flow models to simulate the pressure behavior as well as background noise affecting pressure measurements. In this study, we propose a method to detect the time and volume of fluid leakage based on real-time measurements of well injection and production rates. The approach utilizes analogies between fluid flow and capacitance-resistance modeling. Unlike other leak detection methods (e.g. pressure-based), the proposed method does not require geological and reservoir flow models to simulate the behavior that often carry significant sources of uncertainty; therefore, with our approach the leak can be detected with greater certainty. The method can be applied to detect when a leak begins by tracking a departure in fluid production rate from the expected pattern. The method has been tuned to detect the effect of boundary conditions and fluid compressibility on leakage. To highlight the utility of this approach we use our method to detect leaks for two scenarios. The first scenario simulates a fluid leak from the storage formation into an above-zone monitoring interval. The second scenario simulates intra-reservoir migration between two compartments. We illustrate this method to detect fluid leakage in three different reservoirs with varying levels of geological and structural complexity. The proposed leakage detection method has three novelties: i) requires only readily-available data (injection and production rates), ii) accounts for fluid compressibility and boundary effects, and iii) in addition to

  5. Metastasis of the gastrointestinal tract. FDG-PET imaging

    International Nuclear Information System (INIS)

    Hayasaka, Kazumasa; Nihashi, Takashi; Matsuura, Toshihiro

    2007-01-01

    We assess the usefulness of F-18-fluoro-deoxy-glucose (FDG) positron emission tomography (PET) in the evaluation of gastrointestinal metastases. Four cases (five lesions) in which metastases from three lung cancers and one malignant fibrous histiocytoma (MFH) of the femur were found in the gastrointestinal tract were reviewed (men/women 3:1, age 63-78 years, mean 72 years). The five lesions were duodenal, jejunal metastasis, and two stomach metastases from lung carcinoma, and rectal metastasis from MFH of the femur. FDG-PET was unable to detect small masses, but it was able to detect unforeseen lesions such as gastrointestinal metastases because FDG-PET is a whole-body scan in a single-operation examination. FDG-PET imaging provided valuable information for the diagnosis of gastrointestinal metastasis. (author)

  6. Survival and Prognostic Factors for Metachronous Peritoneal Metastasis in Patients with Colon Cancer.

    Science.gov (United States)

    Nagata, Hiroshi; Ishihara, Soichiro; Hata, Keisuke; Murono, Koji; Kaneko, Manabu; Yasuda, Koji; Otani, Kensuke; Nishikawa, Takeshi; Tanaka, Toshiaki; Kiyomatsu, Tomomichi; Kawai, Kazushige; Nozawa, Hiroaki; Watanabe, Toshiaki

    2017-05-01

    The clinical course of metachronous peritoneal metastasis of colorectal origin is poorly understood. In this retrospective study, we aimed to elucidate survival and prognostic factors for metachronous peritoneal metastasis. Patients with metachronous peritoneal metastasis after curative resection for stage I-III colon cancer were retrospectively reviewed, and the incidence and prognosis of metachronous peritoneal metastasis were investigated. Prognostic factors were identified by univariate and multivariate analyses. Among 1582 surgically resected stage I-III colon cancer patients, 65 developed metachronous peritoneal metastasis. The 5-year cumulative incidence rate was 4.5%, and the median survival after diagnosis of peritoneal metastasis was 29.6 months. None of the patients underwent peritonectomy or intraperitoneal chemotherapy. Independent prognostic factors included right colon cancer [hazard ratio (HR) 2.69, 95% confidence interval (CI) 1.26-5.64; p = 0.011], time to metachronous peritoneal metastasis of Cancer Index (PCI) >10 (HR 3.68, 95% CI 1.37-8.99; p = 0.012), concurrent metastases (HR 4.09, 95% CI 2.02-8.23; p colon cancer patients with metachronous peritoneal metastasis may benefit from combined peritoneal nodule resection and systemic chemotherapy. Right colon cancer, early peritoneal metastasis, a high PCI, and concurrent metastases negatively affected prognosis in patients with metachronous peritoneal metastasis.

  7. Device to detect the presence of a pure signal in a discrete noisy signal measured at an average rate of constant noise with a probability of false detection lower than one predeterminated

    International Nuclear Information System (INIS)

    Poussier, E.; Rambaut, M.

    1986-01-01

    Detection consists of a measurement of a counting rate. A probability of wrong detection is associated with this counting rate and with an average estimated rate of noise. Detection consists also in comparing the wrong detection probability to a predeterminated rate of wrong detection. The comparison can use tabulated values. Application is made to corpuscule radiation detection [fr

  8. Microfilament regulatory protein MENA increases activity of RhoA and promotes metastasis of hepatocellular carcinoma.

    Science.gov (United States)

    Lin, Ling; Yang, Xiao-Mei; Li, Jun; Zhang, Yan-Li; Qin, Wenxin; Zhang, Zhi-Gang

    2014-09-10

    Mammalian enabled (MENA), usually known as a direct regulator of microfilament polymerization and bundling, promotes metastasis in various cancers. Here we focus on the role of MENA in hepatocellular carcinoma (HCC) metastasis and the relevant mechanism from the view of RhoA activity regulation. By HCC tissue microarray analysis, we found that MENA expression was positively associated with satellite lesions (PMENA staining in HCC tissues had significantly higher rates of early recurrence in the intermediate MENA expression group. Knockdown of MENA significantly suppressed HCC cell migration and invasion in vitro, as well as their intrahepatic and distant metastasis in vivo. Knockdown of MENA also decreased filopodia and stress fibers in SMMC-7721 cells. Furthermore, a decrease of RhoA activity was detected by a pull-down assay in SMMC-7721-shMENA cells. The ROCK inhibitor, Y-27632, suppressed migration of both MENA knockdown SMMC-7721 cells and control cells, but diminished their difference. Thus, our findings suggest that MENA promotes HCC cell motility by activating RhoA. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Detection of exudates in fundus imagery using a constant false-alarm rate (CFAR) detector

    Science.gov (United States)

    Khanna, Manish; Kapoor, Elina

    2014-05-01

    Diabetic retinopathy is the leading cause of blindness in adults in the United States. The presence of exudates in fundus imagery is the early sign of diabetic retinopathy so detection of these lesions is essential in preventing further ocular damage. In this paper we present a novel technique to automatically detect exudates in fundus imagery that is robust against spatial and temporal variations of background noise. The detection threshold is adjusted dynamically, based on the local noise statics around the pixel under test in order to maintain a pre-determined, constant false alarm rate (CFAR). The CFAR detector is often used to detect bright targets in radar imagery where the background clutter can vary considerably from scene to scene and with angle to the scene. Similarly, the CFAR detector addresses the challenge of detecting exudate lesions in RGB and multispectral fundus imagery where the background clutter often exhibits variations in brightness and texture. These variations present a challenge to common, global thresholding detection algorithms and other methods. Performance of the CFAR algorithm is tested against a publicly available, annotated, diabetic retinopathy database and preliminary testing suggests that performance of the CFAR detector proves to be superior to techniques such as Otsu thresholding.

  10. Study of bone metastasis of cervical carcinoma by bone scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Okamura, Shinsuke; Okamoto, Yoshiaki; Maeda, Takayoshi; Sano, Takashi; Ueki, Minoru; Sugimoto, Osamu; Sakata, Tsunehiko; Yamasaki, Kouichi; Akagi, Hiroaki

    1985-04-01

    In carrying out bone scintigraphy in 224 cases over the 5 years from June, 1978 to May, 1983 as a part of the post-treatment management of cervical carcinoma. Bone metastases were seen in 12.5% (28 cases) of the subjects, about 6% of the total post-treatment cases of cervical carcinoma in the corresponding period (466 cases). Bone metastases were seen in 9.3% (16/172) of post-operative cases, compared with 23.1% (12/52) of non-operative cases. Bone metastases were not seen in clinical stages Ia through IIa (49 cases) but were seen in IIb or higher stages. Bone metastasis rates by histological type, according to WHO classification, were 12.8% (26/203) in squamous cell carcinoma, 5.9% (1/17) in adenocarcinoma, and 25% (1/4) in adenosquamous carcinoma. Among the squamous cell carcinoma cases, small cell non-keratinizing type had the highest bone metastasis rate. Of 172 post-operative cases, 20.8% (11/53) of those with lymph node metastasis exhibited bone metastasis, higher than the 4.2% (5/119) in cases without lymph node metastasis. As to CPL classification, bone metastasis was seen more often in L type (18.8%) than C(0.0%) or P types (6.6%). Our risk classification of 168 cases demonstrated that bone metastasis was not seen in risk I group (74 cases), but was seen in 6.7% (1/17) of risk II group and in 19.0% (15/79) of risk III group. Twenty-eight cases with bone metastasis included 11 cases with local recurrence, 8 with pulmonary metastases, 4 with hepatic metastases and 4 with Virchow's lymphnode metastases. The 28 bone metastasis cases included 10 cases with multiple bone metastases and 5 with only a single bone metastasis. Most bone metastases were seen in the lumbar vertebrae and the pelvic bone. Post-operative cases had more distant metastases than non-operative cases. On diagnosis of bone metastases and 17 of the 28 patients had pain, 6 of the remaining 11 patients developing pain thereafter. (J.P.N.).

  11. Universal design of a microcontroller and IoT system to detect the heart rate

    Science.gov (United States)

    Uwamahoro, Raphael; Mushikiwabeza, Alexie; Minani, Gerard; Mohan Murari, Bhaskar

    2017-11-01

    Heart rate analysis provides vital information of the present condition of the human body. It helps medical professionals in diagnosis of various malfunctions of the body. The limitation of vision impaired and blind people to access medical devices cause a considerable loss of life. In this paper, we intended to develop a heart rate detection system that is usable for people with normal and abnormal vision. The system is based on a non-invasive method of measuring the variation of the tissue blood flow rate by means of a photo transmitter and detector through fingertip known as photoplethysmography (PPG). The signal detected is firstly passed through active low pass filter and then amplified by a two stages high gain amplifier. The amplified signal is feed into the microcontroller to calculate the heart rate and displays the heart beat via sound systems and Liquid Crystal Display (LCD). To distinguish arrhythmia, normal heart rate and abnormal working conditions of the system, recognition is provided in different sounds, LCD readings and Light Emitting Diodes (LED).

  12. Measurement of the modification and interference rate of urinary albumin detected by size-exclusion HPLC

    International Nuclear Information System (INIS)

    Markó, Lajos; Molnár, Gergő Attila; Wagner, Zoltán; Szijártó, István; Mérei, Ákos; Wittmann, István; Böddi, Katalin; Szabó, Zoltán; Matus, Zoltán; Kőszegi, Tamás; Nagy, Géza

    2009-01-01

    The measurement of the excretion of urinary albumin (albuminuria) is an important and well-established method to assess clinical outcomes. A high-performance liquid chromatography (HPLC) method has been introduced to measure albuminuria. Using this method, it was found that commonly used immunological methods do not measure a fraction of urinary albumin. Some authors presumed that the reason of immuno-unreactivity is the modification of urinary albumin; some others presumed that the difference is merely because of interference. In order to decide this question, we established an HPLC method equipped with tandem UV and fluorescent detection to assess the changes in the detectability of albumin with the rate of modification. For this measurement, differently modified forms of albumin were used. Urine samples of diabetic patients were also measured to find a potential connection between the modification rate and clinical parameters. Secondly, we have established a reversed phase HPLC method to assess the interference rate. We conclude that albumin modification does not affect immunoreactivity. The modification rate of urinary albumin in diabetic patients showed a correlation with renal function. The interference rate of the albumin peak was found to be 12.7% on average, which does not explain the difference between the two methods

  13. Invariance of the bit error rate in the ancilla-assisted homodyne detection

    International Nuclear Information System (INIS)

    Yoshida, Yuhsuke; Takeoka, Masahiro; Sasaki, Masahide

    2010-01-01

    We investigate the minimum achievable bit error rate of the discrimination of binary coherent states with the help of arbitrary ancillary states. We adopt homodyne measurement with a common phase of the local oscillator and classical feedforward control. After one ancillary state is measured, its outcome is referred to the preparation of the next ancillary state and the tuning of the next mixing with the signal. It is shown that the minimum bit error rate of the system is invariant under the following operations: feedforward control, deformations, and introduction of any ancillary state. We also discuss the possible generalization of the homodyne detection scheme.

  14. Reaction rate constant of HO2+O3 measured by detecting HO2 from photofragment fluorescence

    Science.gov (United States)

    Manzanares, E. R.; Suto, Masako; Lee, Long C.; Coffey, Dewitt, Jr.

    1986-01-01

    A room-temperature discharge-flow system investigation of the rate constant for the reaction 'HO2 + O3 yields OH + 2O2' has detected HO2 through the OH(A-X) fluorescence produced by photodissociative excitation of HO2 at 147 nm. A reaction rate constant of 1.9 + or - 0.3 x 10 to the -15th cu cm/molecule per sec is obtained from first-order decay of HO2 in excess O3; this agrees well with published data.

  15. Individual polyp detection rate in routine daily endoscopy practice depends on case-mix.

    Science.gov (United States)

    Loffeld, R J L F; Liberov, B; Dekkers, P E P

    2015-07-01

    The adenoma detection rate (ADR), a marker of endoscopic quality, is confounded by selection bias. It is not known what the ADR is in normal daily practice. To study the polyp detection rate (PDR) in different endoscopists in the course of years. All consecutive endoscopies of the colon done in 11 years were included. Endoscopies in the regular surveillance programme after polyp removal and after surgery because of colorectal cancer or diverticular disease were scored separately. The number of yearly procedures per endoscopist and presence of polyps, anastomoses, surveillance and cancer were noted. In the period of 11 years, 14,908 consecutive endoscopies of colon and rectum were done by four endoscopists. Two endoscopists had a significantly lower PDR than the other two (p case-mix of patients presented for endoscopy. This result debates the use of the ADR as quality indicator for individual endoscopists.

  16. Factors influencing the detection rate of drug-related problems in community pharmacy

    DEFF Research Database (Denmark)

    Westerlund, T; Almarsdóttir, Anna Birna; Melander, A

    1999-01-01

    This study analyzes relationships between the number of drug-related problems detected in community pharmacy practice and the educational level and other characteristics of pharmacy personnel and their work sites. Random samples of pharmacists, prescriptionists and pharmacy technicians were drawn...... by each professional. The regression analysis showed the educational level of the professional to have a statistically significant effect on the detection rate, with pharmacists finding on average 2.5 more drug-related problems per 100 patients than prescriptionists and about 3.6 more than technicians....... The results of this study indicate the importance of education and training of pharmacy personnel in detection of drug-related problems. This findings speaks in favor of increasing the pharmacist to other personnel ratio, provided the higher costs will be offset by societal benefits....

  17. Evaluation of Bone Metastasis from Hepatocellular Carcinoma Using {sup 18F} FDG PET/CT and {sup 99mT}c HDP Bone Scintigraphy: Characteristics of Soft Tissue Formation

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Hyo Jung; Choi, Yun Jung; Kim, Hyun Jeong; Jeong, Youg Hyu; Cho, Arthur; Lee, Jae Hoon; Yun, Mijin; Choi, Hye Jin; Lee, Jong Doo; Kang, Won Jun [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    2011-09-15

    Bone metastasis from hepatocellular carcinoma (HCC) can present with soft tissue formation, resulting in oncologic emergency. Contrast enhanced FDG PET/CT and bone scintigraphy were compared to evaluate characteristics of bone metastases with of without soft tissue formation from HCC. of 4,151 patients with HCC, 263 patients had bone metastases. Eighty five patients with bone metastasis from HCC underwent contrast enhanced FDG PET/CT. Fifty four of the enrolled subjects had recent {sup 99mT}c HDP bone scintigraphy available for comparison. Metastatic bone lesions were identified with visual inspection on FDG PET/CT, and maximum standardized uptake value (SUVmax) was used for the quantitative analysis. Confirmation of bone metastasis was based on histopathology, combined imaging modalities, or serial follow up studies. Forty seven patients (55%) presented with soft tissue formation, while the remaining 38 patients presented without soft tissue formation. Frequent sites of bone metastases from HCC were the spine (39%), pelvis (19%), and rib cage (14%). The soft tissue formation group had more frequent bone pain (77 vs. 37%, p<0.0001), higher SUVmax (6.02 vs. 3.52, p<0.007), and higher incidence of photon defect in bone scintigraphy (75 vs. 0%) compared to the non soft tissue formation group. FDG PET/CT had higher detection rate for bone metastasis than bone scintigraphy both in lesion based analysis (98 vs. 53%, p=0.0015) and in patient based analysis (100 vs. 80%, p<0.001). Bone metastasis from HCC showed a high incidence of soft tissue formation requiring emergency treatment. Although the characteristic findings for soft tissue formation such as photon defect in bone scintigraphy are helpful in detection, overall detectability of bone metastasis is higher in FDG PET/CT. Contrast enhanced PET/CT will be useful in finding and delineating soft tissue forming bone metastasis from HCC.

  18. Double symbol error rates for differential detection of narrow-band FM

    Science.gov (United States)

    Simon, M. K.

    1985-01-01

    This paper evaluates the double symbol error rate (average probability of two consecutive symbol errors) in differentially detected narrow-band FM. Numerical results are presented for the special case of MSK with a Gaussian IF receive filter. It is shown that, not unlike similar results previously obtained for the single error probability of such systems, large inaccuracies in predicted performance can occur when intersymbol interference is ignored.

  19. Non-contact detection of cardiac rate based on visible light imaging device

    Science.gov (United States)

    Zhu, Huishi; Zhao, Yuejin; Dong, Liquan

    2012-10-01

    We have developed a non-contact method to detect human cardiac rate at a distance. This detection is based on the general lighting condition. Using the video signal of human face region captured by webcam, we acquire the cardiac rate based on the PhotoPlethysmoGraphy theory. In this paper, the cardiac rate detecting method is mainly in view of the blood's different absorptivities of the lights various wavelengths. Firstly, we discompose the video signal into RGB three color signal channels and choose the face region as region of interest to take average gray value. Then, we draw three gray-mean curves on each color channel with time as variable. When the imaging device has good fidelity of color, the green channel signal shows the PhotoPlethysmoGraphy information most clearly. But the red and blue channel signals can provide more other physiological information on the account of their light absorptive characteristics of blood. We divide red channel signal by green channel signal to acquire the pulse wave. With the passband from 0.67Hz to 3Hz as a filter of the pulse wave signal and the frequency spectrum superimposed algorithm, we design frequency extracted algorithm to achieve the cardiac rate. Finally, we experiment with 30 volunteers, containing different genders and different ages. The results of the experiments are all relatively agreeable. The difference is about 2bmp. Through the experiment, we deduce that the PhotoPlethysmoGraphy theory based on visible light can also be used to detect other physiological information.

  20. Stereotactic radiosurgery for brain metastasis: Pitie-Salpetriere Hospital experience

    International Nuclear Information System (INIS)

    Feuvret, L.; Germain, I.; Cornu, P.; Boisserie, G.; Dormont, D.; Hardiman, C.; Tep, B.; Faillot, T.; Duffau, H.; Simon, J.M.; Dendale, R.; Delattre, J.Y.; Poisson, M.; Marsault, C.; Philippon, J.; Fohanno, D.; Baillet, F.; Mazeron, J.J.

    1998-01-01

    Retrospective analysis of the influence of clinical and technical factors on local control and survival after radiosurgery for brain metastasis. From january 1994 to December 1996, 42 patients presenting with 71 metastases underwent radiosurgery for brain metastasis. The median age was 56 years and the median Karnofsky index 80. Primary sites included: lung (20 patients), kidney (seven), breast (five), colon (two), melanoma (three), osteosarcoma (one) and it was unknown for three patients. Seventeen patients had extracranial metastasis. Twenty-four patients were treated at recurrence which occurred after whole brain irradiation (12 patients), surgical excision (four) or after both treatments (eight). Thirty-six sessions of radiosurgery have been realized for one metastasis and 13 for two, three or four lesions. The median metastasis diameter was 21 mm and the median volume 1.7 cm 3 . The median peripheral dose to the lesion was 14 Gy, and the median dose at the isocenter 20 Gy. Sixty-five metastasis were evaluable for response analysis. The overall local control rate was 82% and the 1-year actuarial rate was 72%. In univariate analysis, theoretical radioresistance (P = 0.001), diameter less than 3 cm (P = 0.039) and initial treatment with radiosurgery (P 0.041) were significantly associated with increased local control. Only the first two factors remained significant in multivariate analysis. No prognostic factor of overall survival was identified. The median survival was 12 months. Six patients had a symptomatic oedema (RTOG grade 2), only one of which requiring a surgical excision. In conclusion, 14 Gy delivered at the periphery of metastasis seems to be a sufficient dose to control most brain metastases, with a minimal toxicity. Better results were obtained for lesions initially treated with radiosurgery, theoretically radioresistant and with a diameter less than 3 cm. (authors)

  1. A High Performance Impedance-based Platform for Evaporation Rate Detection.

    Science.gov (United States)

    Chou, Wei-Lung; Lee, Pee-Yew; Chen, Cheng-You; Lin, Yu-Hsin; Lin, Yung-Sheng

    2016-10-17

    This paper describes the method of a novel impedance-based platform for the detection of the evaporation rate. The model compound hyaluronic acid was employed here for demonstration purposes. Multiple evaporation tests on the model compound as a humectant with various concentrations in solutions were conducted for comparison purposes. A conventional weight loss approach is known as the most straightforward, but time-consuming, measurement technique for evaporation rate detection. Yet, a clear disadvantage is that a large volume of sample is required and multiple sample tests cannot be conducted at the same time. For the first time in literature, an electrical impedance sensing chip is successfully applied to a real-time evaporation investigation in a time sharing, continuous and automatic manner. Moreover, as little as 0.5 ml of test samples is required in this impedance-based apparatus, and a large impedance variation is demonstrated among various dilute solutions. The proposed high-sensitivity and fast-response impedance sensing system is found to outperform a conventional weight loss approach in terms of evaporation rate detection.

  2. A burst-mode photon counting receiver with automatic channel estimation and bit rate detection

    Science.gov (United States)

    Rao, Hemonth G.; DeVoe, Catherine E.; Fletcher, Andrew S.; Gaschits, Igor D.; Hakimi, Farhad; Hamilton, Scott A.; Hardy, Nicholas D.; Ingwersen, John G.; Kaminsky, Richard D.; Moores, John D.; Scheinbart, Marvin S.; Yarnall, Timothy M.

    2016-04-01

    We demonstrate a multi-rate burst-mode photon-counting receiver for undersea communication at data rates up to 10.416 Mb/s over a 30-foot water channel. To the best of our knowledge, this is the first demonstration of burst-mode photon-counting communication. With added attenuation, the maximum link loss is 97.1 dB at λ=517 nm. In clear ocean water, this equates to link distances up to 148 meters. For λ=470 nm, the achievable link distance in clear ocean water is 450 meters. The receiver incorporates soft-decision forward error correction (FEC) based on a product code of an inner LDPC code and an outer BCH code. The FEC supports multiple code rates to achieve error-free performance. We have selected a burst-mode receiver architecture to provide robust performance with respect to unpredictable channel obstructions. The receiver is capable of on-the-fly data rate detection and adapts to changing levels of signal and background light. The receiver updates its phase alignment and channel estimates every 1.6 ms, allowing for rapid changes in water quality as well as motion between transmitter and receiver. We demonstrate on-the-fly rate detection, channel BER within 0.2 dB of theory across all data rates, and error-free performance within 1.82 dB of soft-decision capacity across all tested code rates. All signal processing is done in FPGAs and runs continuously in real time.

  3. Microenvironment Determinants of Brain Metastasis

    Directory of Open Access Journals (Sweden)

    Zhang Chenyu

    2011-02-01

    Full Text Available Abstract Metastasis accounts for 90% of cancer-related mortality. Brain metastases generally present during the late stages in the natural history of cancer progression. Recent advances in cancer treatment and management have resulted in better control of systemic disease metastatic to organs other than the brain and improved patient survival. However, patients who experience recurrent disease manifest an increasing number of brain metastases, which are usually refractory to therapies. To meet the new challenges of controlling brain metastasis, the research community has been tackling the problem with novel experimental models and research tools, which have led to an improved understanding of brain metastasis. The time-tested "seed-and-soil" hypothesis of metastasis indicates that successful outgrowth of deadly metastatic tumors depends on permissible interactions between the metastatic cancer cells and the site-specific microenvironment in the host organs. Consistently, recent studies indicate that the brain, the major component of the central nervous system, has unique physiological features that can determine the outcome of metastatic tumor growth. The current review summarizes recent discoveries on these tumor-brain interactions, and the potential clinical implications these novel findings could have for the better treatment of patients with brain metastasis.

  4. Reactive Astrocytes in Brain Metastasis

    Directory of Open Access Journals (Sweden)

    David Wasilewski

    2017-12-01

    Full Text Available Brain metastasis, the secondary growth of malignant cells within the central nervous system (CNS, exceeds the incidence of primary brain tumors (i.e., gliomas by tenfold and are seemingly on the rise owing to the emergence of novel targeted therapies that are more effective in controlling extracranial disease relatively to intracranial lesions. Despite the fact that metastasis to the brain poses a unmet clinical problem, with afflicted patients carrying significant morbidity and a fatal prognosis, our knowledge as to how metastatic cells manage to adapt to the tissue environment of the CNS remains limited. Answering this question could pave the way for novel and more specific therapeutic modalities in brain metastasis by targeting the specific makeup of the brain metastatic niche. In regard to this, astrocytes have emerged as the major host cell type that cancer cells encounter and interact with during brain metastasis formation. Similarly to other CNS disorders, astrocytes become reactive and respond to the presence of cancer cells by changing their phenotype and significantly influencing the outcome of disseminated cancer cells within the CNS. Here, we summarize the current knowledge on the contribution of reactive astrocytes in brain metastasis by focusing on the signaling pathways and types of interactions that play a crucial part in the communication with cancer cells and how these could be translated into innovative therapies.

  5. Loss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate

    Directory of Open Access Journals (Sweden)

    M. J. Abbasi

    2016-12-01

    Full Text Available The doubly fed induction generator (DFIG is one of the most popular technologies used in wind power systems. With the growing use of DFIGs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. Loss of excitation (LOE event is among the most frequent failures in electric generators. However, LOE detection studies heretofore were usually confined to synchronous generators. Common LOE detection methods are based on impedance trajectory which makes the system slow and also prone to interpret a stable power swing (SPS as a LOE fault. This paper suggests a new method to detect the LOE based on the measured variables from the DFIG terminal. In this combined method for LOE detection, the rate of change of both the terminal voltage and the output reactive power are utilized and for SPS detection, the fast Fourier transform (FFT analysis of the output instantaneous active power has been used. The performance of the proposed method was evaluated using Matlab/Simulink interface for various power capacities and operating conditions. The results proved the method's quickness, simplicity and security.

  6. HPV detection rate in saliva may depend on the immune system efficiency.

    Science.gov (United States)

    Adamopoulou, Maria; Vairaktaris, Eleftherios; Panis, Vassilis; Nkenke, Emeka; Neukam, Friedreich W; Yapijakis, Christos

    2008-01-01

    Human papilloma virus (HPV) has been established as a major etiological factor of anogenital cancer. In addition, HPV has also been implicated in oral carcinogenesis but its detection rates appear to be highly variable, depending on the patient population tested, the molecular methodology used, as well as the type of oral specimen investigated. For example, saliva is an oral fluid that may play a role in HPV transmission, although the detection rates of the virus are lower than tissue. Recent evidence has indicated that HPV-related pathology is increased in the oral cavity of human immunodeficiency virus (HIV)-positive individuals. In order to investigate whether the presence of different HPV types in saliva depends on immune system efficiency, oral fluid samples of patients with oral cancer and without any known immune deficiency were compared with those of HIV-positive individuals. Saliva samples were collected from 68 patients with oral squamous cell carcinoma and 34 HIV seropositive individuals. HPV DNA sequences were detected by L1 concensus polymerase chain reaction (PCR), followed by restriction fragment length polymorphism (RFLP) analysis and DNA sequencing for HPV typing. HPV DNA was detected in 7/68 (10.3%) of the oral cancer patients and in 12/34 (35.3%) of the HIV-positive individuals, a highly significant difference (p = 0.006; odds ratio 4.753; 95% confidence interval 1.698-13.271). Among HPV-positive samples, the prevalence of HPV types associated with high oncogenic risk was similar in oral cancer and HIV-positive cases (71.4% and 66.7%, respectively). In both groups, the most common HPV type was high-risk 16 (50% and 42.8%, respectively). Although a similar pattern of HPV high-risk types was detected in oral cancer and HIV-positive cases, the quantitative detection of HPV in saliva significantly depended on immune system efficiency. Furthermore, the significantly increased detection rates of HPV in saliva of HIV-positive individuals may be

  7. Developing a Digital Medicine System in Psychiatry: Ingestion Detection Rate and Latency Period.

    Science.gov (United States)

    Profit, Deborah; Rohatagi, Shashank; Zhao, Cathy; Hatch, Ainslie; Docherty, John P; Peters-Strickland, Timothy S

    2016-09-01

    A digital medicine system (DMS) has been developed to measure and report adherence to an atypical antipsychotic, aripiprazole, in psychiatric patients. The DMS consists of 3 components: ingestible sensor embedded in a medication tablet, wearable sensor, and secure mobile and cloud-based applications. An umbrella study protocol was designed to rapidly assess the technical performance and safety of the DMS in multiple substudies to guide the technology development. Two sequential substudies enrolled 30 and 29 healthy volunteers between March-April 2014 and February-March 2015, respectively, to assess detection accuracy of the ingestible sensor by the DMS and the latency period between ingestion and detection of the ingestion by the wearable sensor or the cloud-based server. The first substudy identified areas for improvement using early versions of the wearable sensor and the mobile application. The second substudy tested updated versions of the components and showed an overall ingestion detection rate of 96.6%. Mean latency times for the signal transmission were 1.1-1.3 minutes (from ingestion to the wearable sensor detection) and 6.2-10.3 minutes (from the wearable sensor detection to the server detection). Half of transmissions were completed in < 2 minutes, and ~90% of ingestions were registered by the smartphone within 30 minutes of ingestion. No serious adverse events, discontinuations, or clinically significant laboratory/vital signs findings were reported. The DMS implementing modified versions of the smartphone application and the wearable sensor has the technical capability to detect and report tablet ingestion with high accuracy and acceptable latency time. ClinicalTrials.gov identifier: NCT02091882. © Copyright 2016 Physicians Postgraduate Press, Inc.

  8. A Case of Conjunctival Melanoma Presenting with Breast Metastasis

    Directory of Open Access Journals (Sweden)

    Mustafa Canhoroz

    2014-03-01

    Full Text Available Most breast masses arise from the breast. Metastasis to the breast is fairly uncommon, but can occur in breast skin and parenchyma. In particular, leukemia and lung cancers, and MM may metastasize to the breast. Breast metastasis might be the first symptom or may occur during the course of other malignancies. Our case presented with a fixed mass in the upper-medial quadrant of her left breast during regular follow-up visits. The mean time to breast metastasis in patients with MM is 62 months (13-178. In our case this time was 48 months. In a case series with 7 patients hematological malignancies (Hodgkin lymphoma, non-Hodgkin lymphoma, and leukemia were the leading cause of breast metastasis, whereas in only 1 case the cause was MM. In another case series of 15 MM patients with metastasis to the breast, the primary tumor was frequently localized to the upper extremities and trunk. In a report of 250 conjunctival MM cases the mortality rate was significantly higher in patients with tumors >4 mm in vertical thickness. In another 45-case MM series tumors with a diameter >10 mm were associated with higher mortality rates. In our case the thickness of the tumor was 5 mm. In conclusion, histopathological evaluation should be mandatory in patients with known primary malignancies in order to differentiate new primary tumors, metastases, and benign tumors.

  9. Early detection of pharmacovigilance signals with automated methods based on false discovery rates: a comparative study.

    Science.gov (United States)

    Ahmed, Ismaïl; Thiessard, Frantz; Miremont-Salamé, Ghada; Haramburu, Françoise; Kreft-Jais, Carmen; Bégaud, Bernard; Tubert-Bitter, Pascale

    2012-06-01

    Improving the detection of drug safety signals has led several pharmacovigilance regulatory agencies to incorporate automated quantitative methods into their spontaneous reporting management systems. The three largest worldwide pharmacovigilance databases are routinely screened by the lower bound of the 95% confidence interval of proportional reporting ratio (PRR₀₂.₅), the 2.5% quantile of the Information Component (IC₀₂.₅) or the 5% quantile of the Gamma Poisson Shrinker (GPS₀₅). More recently, Bayesian and non-Bayesian False Discovery Rate (FDR)-based methods were proposed that address the arbitrariness of thresholds and allow for a built-in estimate of the FDR. These methods were also shown through simulation studies to be interesting alternatives to the currently used methods. The objective of this work was twofold. Based on an extensive retrospective study, we compared PRR₀₂.₅, GPS₀₅ and IC₀₂.₅ with two FDR-based methods derived from the Fisher's exact test and the GPS model (GPS(pH0) [posterior probability of the null hypothesis H₀ calculated from the Gamma Poisson Shrinker model]). Secondly, restricting the analysis to GPS(pH0), we aimed to evaluate the added value of using automated signal detection tools compared with 'traditional' methods, i.e. non-automated surveillance operated by pharmacovigilance experts. The analysis was performed sequentially, i.e. every month, and retrospectively on the whole French pharmacovigilance database over the period 1 January 1996-1 July 2002. Evaluation was based on a list of 243 reference signals (RSs) corresponding to investigations launched by the French Pharmacovigilance Technical Committee (PhVTC) during the same period. The comparison of detection methods was made on the basis of the number of RSs detected as well as the time to detection. Results comparing the five automated quantitative methods were in favour of GPS(pH0) in terms of both number of detections of true signals and

  10. Global parameter optimization for maximizing radioisotope detection probabilities at fixed false alarm rates

    Energy Technology Data Exchange (ETDEWEB)

    Portnoy, David, E-mail: david.portnoy@jhuapl.edu [Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD 20723 (United States); Feuerbach, Robert; Heimberg, Jennifer [Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD 20723 (United States)

    2011-10-01

    Today there is a tremendous amount of interest in systems that can detect radiological or nuclear threats. Many of these systems operate in extremely high throughput situations where delays caused by false alarms can have a significant negative impact. Thus, calculating the tradeoff between detection rates and false alarm rates is critical for their successful operation. Receiver operating characteristic (ROC) curves have long been used to depict this tradeoff. The methodology was first developed in the field of signal detection. In recent years it has been used increasingly in machine learning and data mining applications. It follows that this methodology could be applied to radiological/nuclear threat detection systems. However many of these systems do not fit into the classic principles of statistical detection theory because they tend to lack tractable likelihood functions and have many parameters, which, in general, do not have a one-to-one correspondence with the detection classes. This work proposes a strategy to overcome these problems by empirically finding parameter values that maximize the probability of detection for a selected number of probabilities of false alarm. To find these parameter values a statistical global optimization technique that seeks to estimate portions of a ROC curve is proposed. The optimization combines elements of simulated annealing with elements of genetic algorithms. Genetic algorithms were chosen because they can reduce the risk of getting stuck in local minima. However classic genetic algorithms operate on arrays of Booleans values or bit strings, so simulated annealing is employed to perform mutation in the genetic algorithm. The presented initial results were generated using an isotope identification algorithm developed at Johns Hopkins University Applied Physics Laboratory. The algorithm has 12 parameters: 4 real-valued and 8 Boolean. A simulated dataset was used for the optimization study; the 'threat' set of

  11. Global parameter optimization for maximizing radioisotope detection probabilities at fixed false alarm rates

    International Nuclear Information System (INIS)

    Portnoy, David; Feuerbach, Robert; Heimberg, Jennifer

    2011-01-01

    Today there is a tremendous amount of interest in systems that can detect radiological or nuclear threats. Many of these systems operate in extremely high throughput situations where delays caused by false alarms can have a significant negative impact. Thus, calculating the tradeoff between detection rates and false alarm rates is critical for their successful operation. Receiver operating characteristic (ROC) curves have long been used to depict this tradeoff. The methodology was first developed in the field of signal detection. In recent years it has been used increasingly in machine learning and data mining applications. It follows that this methodology could be applied to radiological/nuclear threat detection systems. However many of these systems do not fit into the classic principles of statistical detection theory because they tend to lack tractable likelihood functions and have many parameters, which, in general, do not have a one-to-one correspondence with the detection classes. This work proposes a strategy to overcome these problems by empirically finding parameter values that maximize the probability of detection for a selected number of probabilities of false alarm. To find these parameter values a statistical global optimization technique that seeks to estimate portions of a ROC curve is proposed. The optimization combines elements of simulated annealing with elements of genetic algorithms. Genetic algorithms were chosen because they can reduce the risk of getting stuck in local minima. However classic genetic algorithms operate on arrays of Booleans values or bit strings, so simulated annealing is employed to perform mutation in the genetic algorithm. The presented initial results were generated using an isotope identification algorithm developed at Johns Hopkins University Applied Physics Laboratory. The algorithm has 12 parameters: 4 real-valued and 8 Boolean. A simulated dataset was used for the optimization study; the 'threat' set of spectra

  12. Global parameter optimization for maximizing radioisotope detection probabilities at fixed false alarm rates

    Science.gov (United States)

    Portnoy, David; Feuerbach, Robert; Heimberg, Jennifer

    2011-10-01

    Today there is a tremendous amount of interest in systems that can detect radiological or nuclear threats. Many of these systems operate in extremely high throughput situations where delays caused by false alarms can have a significant negative impact. Thus, calculating the tradeoff between detection rates and false alarm rates is critical for their successful operation. Receiver operating characteristic (ROC) curves have long been used to depict this tradeoff. The methodology was first developed in the field of signal detection. In recent years it has been used increasingly in machine learning and data mining applications. It follows that this methodology could be applied to radiological/nuclear threat detection systems. However many of these systems do not fit into the classic principles of statistical detection theory because they tend to lack tractable likelihood functions and have many parameters, which, in general, do not have a one-to-one correspondence with the detection classes. This work proposes a strategy to overcome these problems by empirically finding parameter values that maximize the probability of detection for a selected number of probabilities of false alarm. To find these parameter values a statistical global optimization technique that seeks to estimate portions of a ROC curve is proposed. The optimization combines elements of simulated annealing with elements of genetic algorithms. Genetic algorithms were chosen because they can reduce the risk of getting stuck in local minima. However classic genetic algorithms operate on arrays of Booleans values or bit strings, so simulated annealing is employed to perform mutation in the genetic algorithm. The presented initial results were generated using an isotope identification algorithm developed at Johns Hopkins University Applied Physics Laboratory. The algorithm has 12 parameters: 4 real-valued and 8 Boolean. A simulated dataset was used for the optimization study; the "threat" set of spectra

  13. Automatic optimisation of gamma dose rate sensor networks: The DETECT Optimisation Tool

    DEFF Research Database (Denmark)

    Helle, K.B.; Müller, T.O.; Astrup, Poul

    2014-01-01

    of the EU FP 7 project DETECT. It evaluates the gamma dose rates that a proposed set of sensors might measure in an emergency and uses this information to optimise the sensor locations. The gamma dose rates are taken from a comprehensive library of simulations of atmospheric radioactive plumes from 64......Fast delivery of comprehensive information on the radiological situation is essential for decision-making in nuclear emergencies. Most national radiological agencies in Europe employ gamma dose rate sensor networks to monitor radioactive pollution of the atmosphere. Sensor locations were often...... source locations. These simulations cover the whole European Union, so the DOT allows evaluation and optimisation of sensor networks for all EU countries, as well as evaluation of fencing sensors around possible sources. Users can choose from seven cost functions to evaluate the capability of a given...

  14. Respiration rate detection based on intensity modulation using plastic optical fiber

    Science.gov (United States)

    Anwar, Zawawi Mohd; Ziran Nurul Sufia, Nor; Hadi, Manap

    2017-11-01

    This paper presents the implementation of respiration rate measurement via a simple intensity-based optical fiber sensor using optical fiber technology. The breathing rate is measured based on the light intensity variation due to the longitudinal gap changes between two separated fibers. In order to monitor the breathing rate continuously, the output from the photodetector conditioning circuit is connected to a low-cost Arduino kit. At the sensing point, two optical fiber cables are positioned in series with a small gap and fitted inside a transparent plastic tube. To ensure smooth movement of the fiber during inhale and exhale processes as well as to maintain the gap of the fiber during idle condition, the fiber is attached firmly to a stretchable bandage. This study shows that this simple fiber arrangement can be applied to detect respiration activity which might be critical for patient monitoring.

  15. Respiration rate detection based on intensity modulation using plastic optical fiber

    Directory of Open Access Journals (Sweden)

    Mohd Anwar Zawawi

    2017-01-01

    Full Text Available This paper presents the implementation of respiration rate measurement via a simple intensity-based optical fiber sensor using optical fiber technology. The breathing rate is measured based on the light intensity variation due to the longitudinal gap changes between two separated fibers. In order to monitor the breathing rate continuously, the output from the photodetector conditioning circuit is connected to a low-cost Arduino kit. At the sensing point, two optical fiber cables are positioned in series with a small gap and fitted inside a transparent plastic tube. To ensure smooth movement of the fiber during inhale and exhale processes as well as to maintain the gap of the fiber during idle condition, the fiber is attached firmly to a stretchable bandage. This study shows that this simple fiber arrangement can be applied to detect respiration activity which might be critical for patient monitoring.

  16. Intracardiac metastasis originated from chondrosarcoma.

    Science.gov (United States)

    Maurea, Nicola; Ragone, Gianluca; Coppola, Carmela; Caronna, Antonietta; Tocchetti, Carlo G; Agozzino, Lucio; Apice, Gaetano; Iaffaioli, Rosario V

    2017-05-01

    Primary cardiac tumors are extremely rare. By comparison, metastatic involvement of the heart is over 20 times more common and has been reported in autopsy series in up to one in five patients dying of cancer. Cardiac metastasis of chondrosarcoma is absolutely not frequent. In the recent literature, a cardiac metastasis from chondrosarcoma has never been described. We report the case of an 18-year-old man with a diagnosis of cardiac metastasis that originated from a left scapular chondrosarcoma. Chondrosarcoma is a skeletal tumor with various grades of malignancy, rapidly evolving, and with a strong tendency to metastasize, with low responsiveness to chemotherapy. The onset of characteristic systemic symptoms in the late stage of the disease led to the diagnosis of a mass localized in the right atrium. Management and differential diagnosis of infective heart lesions were also very complex in a rapidly evolving life-threatening condition.

  17. Improved detection rate of structural abnormalities in the first trimester using an extended examination protocol.

    Science.gov (United States)

    Iliescu, D; Tudorache, S; Comanescu, A; Antsaklis, P; Cotarcea, S; Novac, L; Cernea, N; Antsaklis, A

    2013-09-01

    To assess the potential of first-trimester sonography in the detection of fetal abnormalities using an extended protocol that is achievable with reasonable resources of time, personnel and ultrasound equipment. This was a prospective two-center 2-year study of 5472 consecutive unselected pregnant women examined at 12 to 13 + 6 gestational weeks. Women were examined using an extended morphogenetic ultrasound protocol that, in addition to the basic evaluation, involved a color Doppler cardiac sweep and identification of early contingent markers for major abnormalities. The prevalence of lethal and severe malformations was 1.39%. The first-trimester scan identified 40.6% of the cases detected overall and 76.3% of major structural defects. The first-trimester detection rate (DR) for major congenital heart disease (either isolated or associated with extracardiac abnormalities) was 90% and that for major central nervous system anomalies was 69.5%. In fetuses with increased nuchal translucency (NT), the first-trimester DR for major anomalies was 96%, and in fetuses with normal NT it was 66.7%. Most (67.1%) cases with major abnormalities presented with normal NT. A detailed first-trimester anomaly scan using an extended protocol is an efficient screening method to detect major fetal structural abnormalities in low-risk pregnancies. It is feasible at 12 to 13 + 6 weeks with ultrasound equipment and personnel already used for routine first-trimester screening. Rate of detection of severe malformations is greater in early- than in mid-pregnancy and on postnatal evaluation. Early heart investigation could be improved by an extended protocol involving use of color Doppler. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

  18. Rating the Effectiveness of Fishery Closures With Visible Infrared Imaging Radiometer Suite Boat Detection Data

    Directory of Open Access Journals (Sweden)

    Christopher D. Elvidge

    2018-04-01

    Full Text Available Fishery closures are widely used to promote the sustainability of fish stocks. Fishery agencies typically have very little data relevant to planning closure enforcement actions and evaluating the effectiveness of closures, due in part to the vast expanse and remote nature of many closures. In some cases the effectiveness of closures can be evaluated using data from GPS based beacons, such as Automatic Identification System (AIS or Vessel Monitoring Systems (VMS installed on fishing boats. In fisheries where few boats are equipped with AIS or VMS, the rating of closures relies on other data sources capable of detecting or inferring fishing activity. One such source comes from low light imaging data collected by the NASA/NOAA Visible Infrared Imaging Radiometer Suite (VIIRS, which can detect fishing boats using lights to attract catch. This is a widely used practice in Asia and several other regions. NOAA has developed an automatic system for reporting the locations of VIIRS boat detections with a nominal 4 h temporal latency. VIIRS boat detection alerts are running for more than 900 fishery closures in the Philippines, with email and SMS transmission modes. These alerts are being actively used in the Philippines to plan enforcement actions and there is a growing list of apprehensions that occurred based on tip-offs from VIIRS. The VIIRS boat detection archive extends back to April 2012. A VIIRS closure index (VCI has been developed to rate the effectiveness of closures on monthly increments in terms of a percentage. The VCI analysis was performed on three types of closures: an ad hoc fishery closure associated with a toxic industrial discharge, a seasonal fishery closure and a permanent closure in restricted coastal waters. The VCI results indicate that it is possible to rank the effectiveness of different closure, year-to-year differences in compliance levels, and to identify closure encroachments which may warrant additional enforcement effort.

  19. Direct SUSY dark matter detection-theoretical rates due to the spin

    International Nuclear Information System (INIS)

    Vergados, J D

    2004-01-01

    The recent WMAP data have confirmed that exotic dark matter together with the vacuum energy (cosmological constant) dominate in the flat Universe. Thus direct dark matter detection, consisting of detecting the recoiling nucleus, is central to particle physics and cosmology. Supersymmetry provides a natural dark matter candidate, the lightest supersymmetric particle (LSP). The relevant cross sections arise out of two mechanisms: (i) the coherent mode, due to the scalar interaction and (ii) the spin contribution arising from the axial current. In this paper we will focus on the spin contribution, which is expected to dominate for light targets. For both modes it is possible to obtain detectable rates, but in most models the expected rates are much lower than the present experimental goals. So one should exploit two characteristic signatures of the reaction, namely the modulation effect and in directional experiments the correlation of the event rates with the sun's motion. In standard non-directional experiments the modulation is small, less than 2 per cent. In the case of the directional event rates we would like to suggest that the experiments exploit two features of the process, which are essentially independent of the SUSY model employed, namely: (1) the forward-backward asymmetry, with respect to the sun's direction of motion, is very large and (2) the modulation is much larger, especially if the observation is made in a plane perpendicular to the sun's velocity. In this case the difference between maximum and minimum can be larger than 40 per cent and the phase of the earth at the maximum is direction dependent

  20. Anal metastasis originating from colorectal cancer: Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Min; Lim, Joon Seok; Choi, Jin Young; Park, Mi Suk; Kim, Myeong Jin [Dept. of Radiology and Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul (Korea, Republic of); Chung, Taek; Kim, Ho Guen [Dept. of Pathology, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2016-12-15

    Anal metastasis from colorectal cancer rarely occurs, but it severely impairs the patient's quality of life, often requiring wide resection including the anal sphincter with permanent colostomy. This lesion can be misdiagnosed as a perianal fistula or an abscess, and it can be overlooked at the time of surgery because it is not included in the routine surgical extent of low anterior resection. We report two rare cases of anal metastasis from colorectal cancer. In both cases, perianal nodules with an internal solid portion were detected on preoperative rectal magnetic resonance imaging and additional local excisions of the anal lesions were performed during the process of treatment. Anal metastasis was pathologically confirmed by histology and immunohistochemical staining.

  1. Narrow Band Imaging Enhances the Detection Rate of Penetration and Aspiration in FEES.

    Science.gov (United States)

    Nienstedt, Julie C; Müller, Frank; Nießen, Almut; Fleischer, Susanne; Koseki, Jana-Christiane; Flügel, Till; Pflug, Christina

    2017-06-01

    Narrow band imaging (NBI) is widely used in gastrointestinal, laryngeal, and urological endoscopy. Its original purpose was to visualize vessels and epithelial irregularities. Based on our observation that adding NBI to common white light (WL) improves the contrast of the test bolus in fiberoptic endoscopic evaluation of swallowing (FEES), we now investigated the potential value of NBI in swallowing disorders. 148 FEES images were analyzed from 74 consecutive patients with swallowing disorders, including 74 with and 74 without NBI. All images were evaluated by four dysphagia specialists. Findings were classified according to Rosenbek's penetration-aspiration scale modified for evaluating these FEES images. Intra- and inter-rater reliability was determined as well as observer confidence. A better visualization of the bolus is the main advantage of NBI in FEES. This generally leads to sharper optical contrasts and better detection of small bolus quantities. Accordingly, NBI enhances the detection rate of penetration and aspiration. On average, identification of laryngeal penetration increased from 40 to 73% and of aspiration from 13 to 24% (each p dysphagia evaluation and shortening FEES evaluation time. It leads to a markedly higher detection rate of pathological findings. The significantly better intra- and inter-rater reliability argues further for a better overall reproducibly of FEES interpretation.

  2. Fetal QRS detection and heart rate estimation: a wavelet-based approach

    International Nuclear Information System (INIS)

    Almeida, Rute; Rocha, Ana Paula; Gonçalves, Hernâni; Bernardes, João

    2014-01-01

    Fetal heart rate monitoring is used for pregnancy surveillance in obstetric units all over the world but in spite of recent advances in analysis methods, there are still inherent technical limitations that bound its contribution to the improvement of perinatal indicators. In this work, a previously published wavelet transform based QRS detector, validated over standard electrocardiogram (ECG) databases, is adapted to fetal QRS detection over abdominal fetal ECG. Maternal ECG waves were first located using the original detector and afterwards a version with parameters adapted for fetal physiology was applied to detect fetal QRS, excluding signal singularities associated with maternal heartbeats. Single lead (SL) based marks were combined in a single annotator with post processing rules (SLR) from which fetal RR and fetal heart rate (FHR) measures can be computed. Data from PhysioNet with reference fetal QRS locations was considered for validation, with SLR outperforming SL including ICA based detections. The error in estimated FHR using SLR was lower than 20 bpm for more than 80% of the processed files. The median error in 1 min based FHR estimation was 0.13 bpm, with a correlation between reference and estimated FHR of 0.48, which increased to 0.73 when considering only records for which estimated FHR > 110 bpm. This allows us to conclude that the proposed methodology is able to provide a clinically useful estimation of the FHR. (paper)

  3. Rate of detection of advanced neoplasms in proximal colon by simulated sigmoidoscopy vs fecal immunochemical tests.

    Science.gov (United States)

    Castells, Antoni; Quintero, Enrique; Álvarez, Cristina; Bujanda, Luis; Cubiella, Joaquín; Salas, Dolores; Lanas, Angel; Carballo, Fernando; Morillas, Juan Diego; Hernández, Cristina; Jover, Rodrigo; Hijona, Elizabeth; Portillo, Isabel; Enríquez-Navascués, José M; Hernández, Vicent; Martínez-Turnes, Alfonso; Menéndez-Villalva, Carlos; González-Mao, Carmen; Sala, Teresa; Ponce, Marta; Andrés, Mercedes; Teruel, Gloria; Peris, Antonio; Sopeña, Federico; González-Rubio, Francisca; Seoane-Urgorri, Agustín; Grau, Jaume; Serradesanferm, Anna; Pozo, Àngels; Pellisé, Maria; Balaguer, Francesc; Ono, Akiko; Cruzado, José; Pérez-Riquelme, Francisco; Alonso-Abreu, Inmaculada; Carrillo-Palau, Marta; de la Vega-Prieto, Mariola; Iglesias, Rosario; Amador, Javier; Blanco, José Manuel; Sastre, Rocio; Ferrándiz, Juan; González-Hernández, Ma José; Andreu, Montserrat; Bessa, Xavier

    2014-10-01

    We compared the ability of biennial fecal immunochemical testing (FIT) and one-time sigmoidoscopy to detect colon side-specific advanced neoplasms in a population-based, multicenter, nationwide, randomized controlled trial. We identified asymptomatic men and women, 50-69 years old, through community health registries and randomly assigned them to groups that received a single colonoscopy examination or biennial FIT. Sigmoidoscopy yield was simulated from results obtained from the colonoscopy group, according to the criteria proposed in the UK Flexible Sigmoidoscopy Trial for colonoscopy referral. Patients who underwent FIT and were found to have ≥75 ng hemoglobin/mL were referred for colonoscopy. Data were analyzed from 5059 subjects in the colonoscopy group and 10,507 in the FIT group. The main outcome was rate of detection of any advanced neoplasm proximal to the splenic flexure. Advanced neoplasms were detected in 317 subjects (6.3%) in the sigmoidoscopy simulation group compared with 288 (2.7%) in the FIT group (odds ratio for sigmoidoscopy, 2.29; 95% confidence interval, 1.93-2.70; P = .0001). Sigmoidoscopy also detected advanced distal neoplasia in a higher percentage of patients than FIT (odds ratio, 2.61; 95% confidence interval, 2.20-3.10; P = .0001). The methods did not differ significantly in identifying patients with advanced proximal neoplasms (odds ratio, 1.17; 95% confidence interval, 0.78-1.76; P = .44). This was probably due to the lower performance of both strategies in detecting patients with proximal lesions (sigmoidoscopy detected these in 19.1% of patients and FIT in 14.9% of patients) vs distal ones (sigmoidoscopy detected these in 86.8% of patients and FIT in 33.5% of patients). Sigmoidoscopy, but not FIT, detected proximal lesions in lower percentages of women (especially those 50-59 years old) than men. Sigmoidoscopy and FIT have similar limitations in detecting advanced proximal neoplasms, which depend on patients' characteristics

  4. Detecting Parental Deception Using a Behavior Rating Scale during Assessment of Attention-Deficit/Hyperactivity Disorder: An Experimental Study

    Science.gov (United States)

    Norfolk, Philip A.; Floyd, Randy G.

    2016-01-01

    It is often assumed that parents completing behavior rating scales during the assessment of attention-deficit/hyperactivity disorder (ADHD) can deliberately manipulate the outcomes of the assessment. To detect these actions, items designed to detect over-reporting or under-reporting of results are sometimes embedded in such rating scales. This…

  5. Cutaneous metastasis of bilateral renal cell carcinoma.

    Science.gov (United States)

    Abbasi, Fariba; Alizadeh, Mansur; Noroozinia, Farahnaz; Moradi, Amin

    2013-01-01

    Renal cell carcinoma (RCC) is a malignant lethal tumour with high potential of metastasis. However, metastasis from RCC to the skin is much less common. It is virtually a sign of poor prognosis. We represent a 42 years old man with bilateral RCC of clear cell type followed by metastasis to the scalp one month later. In this case the relatively young age of the patient, bilaterality of RCC and occurance of skin metastasis in the absence of recurrent kidney tumour are interesting.

  6. A Hybrid Islanding Detection Technique Using Average Rate of Voltage Change and Real Power Shift

    DEFF Research Database (Denmark)

    Mahat, Pukar; Chen, Zhe; Bak-Jensen, Birgitte

    2009-01-01

    The mainly used islanding detection techniques may be classified as active and passive techniques. Passive techniques don't perturb the system but they have larger nondetection znes, whereas active techniques have smaller nondetection zones but they perturb the system. In this paper, a new hybrid...... technique is proposed to solve this problem. An average rate of voltage change (passive technique) has been used to initiate a real power shift (active technique), which changes the eal power of distributed generation (DG), when the passive technique cannot have a clear discrimination between islanding...

  7. Comparison of detectable bleeding rates of radiopharmaceuticals for localization of gastrointestinal bleeding in sheep using a closed system

    Energy Technology Data Exchange (ETDEWEB)

    Owunwanne, A.; Sadek, S.; Yacoub, T.; Awdeh, M.; Abdel-Dayem, H.M. (Kuwait Univ. (Kuwait). Dept. of Nuclear Medicine); Al-Wafai, I.; Vallgren, S. (Kuwait Univ. (Kuwait). Dept. of Surgery)

    1989-06-01

    The closed experimental animal model system was used to compare the detectable gastrointestinal (GI) bleeding rates of {sup 99m}Tc-DTPA, {sup 99m}Tc-RBCs and {sup 99m}Tc tin colloid in sheep. The three radiopharmaceuticals were used to detect the upper GI bleeding sites at rates of 0.57 and 0.25 ml/min. At the lower bleeding rate of 0.1 ml/min, both {sup 99m}Tc-DTPA and {sup 99m}Tc-RBCs were successful in detecting the bleeding site. At the lowest rate of 0.07 ml/min only {sup 99m}Tc-DTPA was successful in detecting the bleeding site. The results indicate that {sup 99m}Tc-DTPA is the most useful {sup 99m}Tc radiopharmaceutical for detecting the upper GI bleeding site at the slowest bleeding rate studied. (orig.).

  8. Comparison of detectable bleeding rates of radiopharmaceuticals for localization of gastrointestinal bleeding in sheep using a closed system

    International Nuclear Information System (INIS)

    Owunwanne, A.; Sadek, S.; Yacoub, T.; Awdeh, M.; Abdel-Dayem, H.M.; Al-Wafai, I.; Vallgren, S.

    1989-01-01

    The closed experimental animal model system was used to compare the detectable gastrointestinal (GI) bleeding rates of 99m Tc-DTPA, 99m Tc-RBCs and 99m Tc tin colloid in sheep. The three radiopharmaceuticals were used to detect the upper GI bleeding sites at rates of 0.57 and 0.25 ml/min. At the lower bleeding rate of 0.1 ml/min, both 99m Tc-DTPA and 99m Tc-RBCs were successful in detecting the bleeding site. At the lowest rate of 0.07 ml/min only 99m Tc-DTPA was successful in detecting the bleeding site. The results indicate that 99m Tc-DTPA is the most useful 99m Tc radiopharmaceutical for detecting the upper GI bleeding site at the slowest bleeding rate studied. (orig.) [de

  9. [Design of Oxygen Saturation, Heart Rate, Respiration Rate Detection System Based on Smartphone of Android Operating System].

    Science.gov (United States)

    Zhu, Mingshan; Zeng, Bixin

    2015-03-01

    In this paper, we designed an oxygen saturation, heart rate, respiration rate monitoring system based on smartphone of android operating system, physiological signal acquired by MSP430 microcontroller and transmitted by Bluetooth module.

  10. Metastasis genetics, epigenetics, and the tumor microenvironment

    Science.gov (United States)

    KISS1 is a member of a family of genes known as metastasis suppressors, defined by their ability to block metastasis without blocking primary tumor development and growth. KISS1 re-expression in multiple metastatic cell lines of diverse cellular origin suppresses metastasis; yet, still allows comple...

  11. Hidradenocarcinoma of the Scrotum with Lymph Node Metastasis

    Directory of Open Access Journals (Sweden)

    Maria Inês Simões

    2018-03-01

    Full Text Available Hidradenocarcinoma is a rare neoplasm of the eccrine cells of the sweat glands, usually asymptomatic with slow growing and higher incidence between 50 and 80 years, occurring in both sexes and preferentially located in the palmar, plantar, frontal, axillary and nuchal regions. It has an aggressive behavior, with high rate of local recurrence and distance metastasis, associated with a poor prognosis. We present a case of hidradenocarcinoma of the scrotum manifested by lymph node metastasis through an exercise of clinical and histological differential diagnosis of an inguinal adenopathy in a young adult.

  12. [Hidradenocarcinoma of the Scrotum with Lymph Node Metastasis].

    Science.gov (United States)

    Simões, Maria Inês; Marcão, Isabel; Toscano, Mário; Borges, Luís

    2018-03-29

    Hidradenocarcinoma is a rare neoplasm of the eccrine cells of the sweat glands, usually asymptomatic with slow growing and higher incidence between 50 and 80 years, occurring in both sexes and preferentially located in the palmar, plantar, frontal, axillary and nuchal regions. It has an aggressive behavior, with high rate of local recurrence and distance metastasis, associated with a poor prognosis. We present a case of hidradenocarcinoma of the scrotum manifested by lymph node metastasis through an exercise of clinical and histological differential diagnosis of an inguinal adenopathy in a young adult.

  13. Gut metastasis from breast carcinoma.

    Science.gov (United States)

    Al-Qahtani, Mohammed S

    2007-10-01

    Breast cancer is the second most common malignancy in women. Common sites of metastases include the liver, lung, bone, and the brain. Metastases to the gastrointestinal tract are rare with patients presenting with small-bowel perforation, intestinal obstruction, and gastrointestinal bleeding. Here we report a case of a Saudi female presenting with invasive lobular carcinoma and ileo-cecal junction metastasis.

  14. Gut metastasis from breast carcinoma

    International Nuclear Information System (INIS)

    Al-Qahtani, Mohammad S.

    2007-01-01

    Breast cancer is the second most common malignancy in women. Common sites of metastases include the liver, lung, bone and the brain. Metastases to the gastrointestinal tract are with patients presenting with small-bowel perforation, intestinal obstruction and gastrointestinal bleeding. Here we report a case of Saudi female presenting with invasive lobular carcinoma and i leo-junction metastasis. (author)

  15. Pulmonary Metastasis from Pseudomyxoma Peritonei

    Directory of Open Access Journals (Sweden)

    Toshiyuki Kitai

    2012-01-01

    Full Text Available Pseudomyxoma peritonei (PMP is a rare clinical condition, where copious mucinous ascites accumulate in the peritoneal cavity due to dissemination of mucin-producing tumor. Because of this disseminating, yet nonmetastasizing, behavior, PMP attracts much interest from surgical oncologists in that aggressive locoregional therapy can give the opportunity of long survival and even cure. Although extra-abdominal metastasis is exceptionally rare, the lung is the most likely site in such a case. In this paper, the clinical findings and treatment of eleven cases with pulmonary metastasis from PMP were reviewed, including ten cases in the literature and one case which we experienced. The clinical features of PMP cases with pulmonary metastasis were similar to cases without pulmonary metastasis. The histological type was low-grade mucinous neoplasm in most cases. Pulmonary lesions were resected in seven cases in which abdominal lesions were controlled by cytoreductive surgery and hyperthermic intraperitoneal chemotherapy or another therapeutic modality. Disease-free state was maintained in five cases at the end of the follow-up period. However, it should be noted that rapid progression after resection was seen in two cases, suggesting that biological features may have changed by surgical intervention.

  16. A method of detection of respiration rate on Android using UWB Impulse Radar

    Directory of Open Access Journals (Sweden)

    Young-Jin Park

    2016-12-01

    Full Text Available Monitoring respiration rate is important because it can help to detect and prevent abnormal respiratory rates that can lead to cardiac arrest and chronic obstructive pulmonary disease. Nowadays, most medical measurement and monitoring devices are either invasive or wired but people are hesitant to attach physiological sensors to their body. In this study, we investigated whether real-time medical measurement of breathing using Novelda’s Ultra-Wideband Impulse Radio (IR-UWB–which does not need to be attached to the human body and is also non-invasive–is possible on Android. Experimental results obtained were found to be comparable to those of a commercial healthcare device.

  17. Cooperation schemes for rate enhancement in detect-and-forward relay channels

    KAUST Repository

    Benjillali, Mustapha

    2010-05-01

    To improve the spectral efficiency of "Detect-and-Forward" (DetF) half-duplex relaying in fading channels, we propose a cooperation scheme where the relay uses a modulation whose order is higher than the one at the source. In a new common framework, we show that the proposed scheme offers considerable gains - in terms of achievable information rates - compared to the conventional DetF relaying schemes for both orthogonal and non-orthogonal source/relay cooperation. This allows us to propose an adaptive cooperation scheme based on the maximization of the information rate at the destination which needs to observe only the average signal-to-noise ratios of direct and relaying links. ©2010 IEEE.

  18. Active Tobacco Smoking and Distant Metastasis in Patients With Oropharyngeal Cancer

    Energy Technology Data Exchange (ETDEWEB)

    McBride, Sean M. [Harvard Radiation Oncology Program, Boston, Massachusetts (United States); Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts (United States); Ali, Nawal N. [Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts (United States); Margalit, Danielle N. [Harvard Radiation Oncology Program, Boston, Massachusetts (United States); Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts (United States); Chan, Annie W., E-mail: awchan@partners.org [Department of Radiation Oncology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts (United States)

    2012-09-01

    Purpose: Distant metastasis is the site of first relapse in approximately one-third of patients with locally advanced oropharyngeal carcinoma, irrespective of human papillomavirus status. Yet the risk factors associated with distant metastasis are not well characterized. We sought to characterize the relationship between smoking status and distant metastasis. Methods and Materials: We evaluated the association between tobacco smoking status and distant metastasis in a retrospective cohort study of 132 patients who underwent definitive radiation therapy and chemotherapy for Stage III-IVA/B oropharyngeal cancer. Information on tobacco smoking was prospectively collected by patient questionnaires and physician notes at the time of diagnosis. Thirty-three percent of the patients were nonsmokers, 51% were former smokers, 16% were active smokers. The cumulative lifetime tobacco smoking in pack-years was 20 (range, 0-150). Results: With a median follow-up time of 52 months, the overall rate of distant metastasis at 4 years was 8%. Distant metastasis was the most common first site of relapse, occurring in 56% of the patients with recurrences. Active smokers had higher rates of distant metastasis than non-active smokers (including never- and former smokers; 31% vs. 4%, p < 0.001) and former smokers (31% vs. 3%, p < 0.001). There was no statistically significant difference in the risk of distant metastasis for patients with lifetime cumulative pack-years >20 and {<=}20 (10% vs. 4%, p = 0.19). In univariate analysis, active smoking (p = 0.0004) and N category (p = 0.009) were predictive of increased risk of distant metastasis. In multivariate analysis, active smoking was the most significant predictive factor for increased risk of distant metastasis (hazard ratio, 12.7, p < 0.0001). Conclusions: This study identified a strong association between active smoking and distant metastasis in patients with oropharyngeal cancer.

  19. Clinicopathologic risk factors for right paraesophageal lymph node metastasis in patients with papillary thyroid carcinoma.

    Science.gov (United States)

    Yu, Q A; Ma, D K; Liu, K P; Wang, P; Xie, C M; Wu, Y H; Dai, W J; Jiang, H C

    2018-03-17

    To investigate risk factors associated with right paraesophageal lymph node (RPELN) metastasis in patients with papillary thyroid carcinoma (PTC) and to determine the indications for right lymph node dissection. Clinicopathologic data from 829 patients (104 men and 725 women) with PTC, operated on by the same thyroid surgery team at the First Affiliated Hospital of Harbin Medical University from January 2013 to May 2017, were analyzed. Overall, 309 patients underwent total thyroidectomy with bilateral lymph node dissection, 488 underwent right thyroid lobe and isthmic resection with right central compartment lymph node dissection, and 32 underwent near-total thyroidectomy (ipsilateral thyroid lobectomy with contralateral near-total lobectomy) with bilateral lymph node dissection. The overall rate of central compartment lymph node metastasis was 43.5% (361/829), with right central compartment lymph node and RPELN metastasis rates of 35.5% (294/829) and 19.1% (158/829), respectively. Tumor size, number, invasion, and location, lymph node metastasis, right central compartment lymph node metastasis, and right lateral compartment lymph node metastasis were associated with RPELN in the univariate analysis, whereas age and sex were not. Multivariate analysis identified tumors with a diameter ≥ 1 cm, multiple tumors, tumors located in the right lobe, right central compartment lymph node metastasis, and right lateral compartment lymph node metastasis as independent risk factors for RPELN metastasis. Lymph node dissection, including RPELN dissection, should be performed for patients with PTC with a tumor diameter ≥ 1 cm, multiple tumors, right-lobe tumors, right central compartment lymph node metastasis, or suspected lateral compartment lymph node metastasis.

  20. Nonlinear detection for a high rate extended binary phase shift keying system.

    Science.gov (United States)

    Chen, Xian-Qing; Wu, Le-Nan

    2013-03-28

    The algorithm and the results of a nonlinear detector using a machine learning technique called support vector machine (SVM) on an efficient modulation system with high data rate and low energy consumption is presented in this paper. Simulation results showed that the performance achieved by the SVM detector is comparable to that of a conventional threshold decision (TD) detector. The two detectors detect the received signals together with the special impacting filter (SIF) that can improve the energy utilization efficiency. However, unlike the TD detector, the SVM detector concentrates not only on reducing the BER of the detector, but also on providing accurate posterior probability estimates (PPEs), which can be used as soft-inputs of the LDPC decoder. The complexity of this detector is considered in this paper by using four features and simplifying the decision function. In addition, a bandwidth efficient transmission is analyzed with both SVM and TD detector. The SVM detector is more robust to sampling rate than TD detector. We find that the SVM is suitable for extended binary phase shift keying (EBPSK) signal detection and can provide accurate posterior probability for LDPC decoding.

  1. Nonlinear Detection for a High Rate Extended Binary Phase Shift Keying System

    Directory of Open Access Journals (Sweden)

    Le-Nan Wu

    2013-03-01

    Full Text Available The algorithm and the results of a nonlinear detector using a machine learning technique called support vector machine (SVM on an efficient modulation system with high data rate and low energy consumption is presented in this paper. Simulation results showed that the performance achieved by the SVM detector is comparable to that of a conventional threshold decision (TD detector. The two detectors detect the received signals together with the special impacting filter (SIF that can improve the energy utilization efficiency. However, unlike the TD detector, the SVM detector concentrates not only on reducing the BER of the detector, but also on providing accurate posterior probability estimates (PPEs, which can be used as soft-inputs of the LDPC decoder. The complexity of this detector is considered in this paper by using four features and simplifying the decision function. In addition, a bandwidth efficient transmission is analyzed with both SVM and TD detector. The SVM detector is more robust to sampling rate than TD detector. We find that the SVM is suitable for extended binary phase shift keying (EBPSK signal detection and can provide accurate posterior probability for LDPC decoding.

  2. Detection rates of geckos in visual surveys: Turning confounding variables into useful knowledge

    Science.gov (United States)

    Lardner, Bjorn; Rodda, Gordon H.; Yackel Adams, Amy A.; Savidge, Julie A.; Reed, Robert N.

    2016-01-01

    Transect surveys without some means of estimating detection probabilities generate population size indices prone to bias because survey conditions differ in time and space. Knowing what causes such bias can help guide the collection of relevant survey covariates, correct the survey data, anticipate situations where bias might be unacceptably large, and elucidate the ecology of target species. We used negative binomial regression to evaluate confounding variables for gecko (primarily Hemidactylus frenatus and Lepidodactylus lugubris) counts on 220-m-long transects surveyed at night, primarily for snakes, on 9,475 occasions. Searchers differed in gecko detection rates by up to a factor of six. The worst and best headlamps differed by a factor of at least two. Strong winds had a negative effect potentially as large as those of searchers or headlamps. More geckos were seen during wet weather conditions, but the effect size was small. Compared with a detection nadir during waxing gibbous (nearly full) moons above the horizon, we saw 28% more geckos during waning crescent moons below the horizon. A sine function suggested that we saw 24% more geckos at the end of the wet season than at the end of the dry season. Fluctuations on a longer timescale also were verified. Disturbingly, corrected data exhibited strong short-term fluctuations that covariates apparently failed to capture. Although some biases can be addressed with measured covariates, others will be difficult to eliminate as a significant source of error in longterm monitoring programs.

  3. A Comparative Survey of Methods for Remote Heart Rate Detection From Frontal Face Videos

    Directory of Open Access Journals (Sweden)

    Chen Wang

    2018-05-01

    Full Text Available Remotely measuring physiological activity can provide substantial benefits for both the medical and the affective computing applications. Recent research has proposed different methodologies for the unobtrusive detection of heart rate (HR using human face recordings. These methods are based on subtle color changes or motions of the face due to cardiovascular activities, which are invisible to human eyes but can be captured by digital cameras. Several approaches have been proposed such as signal processing and machine learning. However, these methods are compared with different datasets, and there is consequently no consensus on method performance. In this article, we describe and evaluate several methods defined in literature, from 2008 until present day, for the remote detection of HR using human face recordings. The general HR processing pipeline is divided into three stages: face video processing, face blood volume pulse (BVP signal extraction, and HR computation. Approaches presented in the paper are classified and grouped according to each stage. At each stage, algorithms are analyzed and compared based on their performance using the public database MAHNOB-HCI. Results found in this article are limited on MAHNOB-HCI dataset. Results show that extracted face skin area contains more BVP information. Blind source separation and peak detection methods are more robust with head motions for estimating HR.

  4. Heart Rate Detection Using Microsoft Kinect: Validation and Comparison to Wearable Devices.

    Science.gov (United States)

    Gambi, Ennio; Agostinelli, Angela; Belli, Alberto; Burattini, Laura; Cippitelli, Enea; Fioretti, Sandro; Pierleoni, Paola; Ricciuti, Manola; Sbrollini, Agnese; Spinsante, Susanna

    2017-08-02

    Contactless detection is one of the new frontiers of technological innovation in the field of healthcare, enabling unobtrusive measurements of biomedical parameters. Compared to conventional methods for Heart Rate (HR) detection that employ expensive and/or uncomfortable devices, such as the Electrocardiograph (ECG) or pulse oximeter, contactless HR detection offers fast and continuous monitoring of heart activities and provides support for clinical analysis without the need for the user to wear a device. This paper presents a validation study for a contactless HR estimation method exploiting RGB (Red, Green, Blue) data from a Microsoft Kinect v2 device. This method, based on Eulerian Video Magnification (EVM), Photoplethysmography (PPG) and Videoplethysmography (VPG), can achieve performance comparable to classical approaches exploiting wearable systems, under specific test conditions. The output given by a Holter, which represents the gold-standard device used in the test for ECG extraction, is considered as the ground-truth, while a comparison with a commercial smartwatch is also included. The validation process is conducted with two modalities that differ for the availability of a priori knowledge about the subjects' normal HR. The two test modalities provide different results. In particular, the HR estimation differs from the ground-truth by 2% when the knowledge about the subject's lifestyle and his/her HR is considered and by 3.4% if no information about the person is taken into account.

  5. Cardiac arrhythmia detection using combination of heart rate variability analyses and PUCK analysis.

    Science.gov (United States)

    Mahananto, Faizal; Igasaki, Tomohiko; Murayama, Nobuki

    2013-01-01

    This paper presents cardiac arrhythmia detection using the combination of a heart rate variability (HRV) analysis and a "potential of unbalanced complex kinetics" (PUCK) analysis. Detection performance was improved by adding features extracted from the PUCK analysis. Initially, R-R interval data were extracted from the original electrocardiogram (ECG) recordings and were cut into small segments and marked as either normal or arrhythmia. HRV analyses then were conducted using the segmented R-R interval data, including a time-domain analysis, frequency-domain analysis, and nonlinear analysis. In addition to the HRV analysis, PUCK analysis, which has been implemented successfully in a foreign exchange market series to characterize change, was employed. A decision-tree algorithm was applied to all of the obtained features for classification. The proposed method was tested using the MIT-BIH arrhythmia database and had an overall classification accuracy of 91.73%. After combining features obtained from the PUCK analysis, the overall accuracy increased to 92.91%. Therefore, we suggest that the use of a PUCK analysis in conjunction with HRV analysis might improve performance accuracy for the detection of cardiac arrhythmia.

  6. Dedicated Barrett's surveillance sessions managed by trained endoscopists improve dysplasia detection rate.

    Science.gov (United States)

    Ooi, Joanne; Wilson, Patrick; Walker, Giles; Blaker, Paul; DeMartino, Sabina; O'Donohue, John; Reffitt, David; Lanaspre, Effie; Chang, Fuju; Meenan, John; Dunn, Jason M

    2017-06-01

    Background and study aim  Barrett's esophagus (BE)-associated dysplasia is an important marker for risk of progression to esophageal adenocarcinoma (EAC) and an indication for endoscopic therapy. However, BE surveillance technique is variable. The aim of this study was to assess the effect of dedicated BE surveillance lists on dysplasia detection rate (DDR). Patients and methods  This was a prospective study of patients undergoing BE surveillance at two hospitals - community (UHL) and upper gastrointestinal center (GSTT). Four endoscopists (Group A) were trained in Prague classification, Seattle protocol biopsy technique, and lesion detection prior to performing BE surveillance endoscopies at both sites, with dedicated time slots or lists. The DDR was then compared with historical data from 47 different endoscopists at GSTT and 24 at UHL (Group B) who had undertaken Barrett's surveillance over the preceding 5-year period. Results  A total of 729 patients with BE underwent surveillance endoscopy between 2007 and 2012. There was no significant difference in patient age, sex, or length of BE between the two groups. There was a significant difference in detection rate of confirmed indefinite or low grade dysplasia and high grade dysplasia (HGD)/EAC between the two groups: 18 % (26 /142) Group A vs. 8 % (45/587) in Group B ( P  < 0.001). Documentation of Prague criteria and adherence to the Seattle protocol was significantly higher in Group A. Conclusion  This study demonstrated that a group of trained endoscopists undertaking Barrett's surveillance on dedicated lists had significantly higher DDR than a nonspecialist cohort. These findings support the introduction of dedicated Barrett's surveillance lists. © Georg Thieme Verlag KG Stuttgart · New York.

  7. [A case of transverse colon cancer without a recurrence lesion after five years from resection of hepatic metastasis].

    Science.gov (United States)

    Ami, Katsunori; Nakamura, Masahiro; Takasaki, Jun; Watayou, Yoshihisa; Amagasa, Hidetoshi; Ganno, Hideaki; Kurokawa, Toshiaki; Fukuda, Akira; Nagahama, Takeshi; Ando, Masayuki; Tei, Shikofumi; Okada, Youichi; Arai, Kuniyoshi

    2011-11-01

    The treatment of hepatic metastasis of colon cancer was in progress by new biochemical agents. Generally, a resection was the first alternative treatment against hepatic metastasis of colon cancer, but new antitumor agents were more effective than conventional antitumor agents. Disappearance of metastasis for colon cancer treated with only antitumor agents was commenced to report. We were experienced a case of transverse colon cancer without a recurrence lesion after five years from the resection of hepatic metastasis. A case was a 77-year-old man. He was operated against transverse colon cancer in February 2003. Pathological stage was ss, n0, Stage II. In April 2004, serum CEA was increased. CT examination was not detected a hepatic metastasis but ultrasound examination and MRI detected the metastasis at S7 lesion in the liver. In July 2004, he was admitted to S-1 and PSK until October 2004. In December 2004, the lesion of hepatic metastasis was reduced and serum CEA was decreased. But in September 2005, the metastatic lesion was re-grown. A resection for hepatic metastasis was executed in November 2005. After the resection for hepatic metastasis, he was admitted to UFT/ UZEL from January 2006 to October 2006. Present time( June 2011), the lesion of recurrence was not detected by several examinations (CT, MRI, Ultrasound etc).

  8. Searching early bone metastasis on plain radiography by using digital imaging processing

    Energy Technology Data Exchange (ETDEWEB)

    Jaramillo-Nunez, A.; Perez-Meza, M. [Instituto Nacional de Astrofisica, Optica y Electronica, Apdo. Postal 51 y 216, Pue. (Mexico); Universidad de la Sierra Sur, C. P. 70800, Miahuatlan, Oax. (Mexico)

    2012-10-23

    Some authors mention that it is not possible to detect early bone metastasis on plain radiography. In this work we use digital imaging processing to analyze three radiographs taken from a patient with bone metastasis discomfort on the right shoulder. The time period among the first and second radiography was approximately one month and between the first and the third one year. This procedure is a first approach in order to know if in this particular case it was possible to detect an early bone metastasis. The obtained results suggest that by carrying out a digital processing is possible to detect the metastasis since the radiography contains the information although visually it is not possible to observe it.

  9. Effect of recall rate on earlier screen detection of breast cancers based on the Dutch performance indicators.

    NARCIS (Netherlands)

    Otten, J.D.M.; Karssemeijer, N.; Hendriks, J.H.C.L.; Groenewoud, J.H.; Fracheboud, J.; Verbeek, A.L.M.; Koning, H.J. de; Holland, R.

    2005-01-01

    BACKGROUND: The recall rate (i.e., the rate at which mammographically screened women are recalled for additional assessment) in the Dutch breast screening program (0.89% in 2000 for subsequent examinations) is the lowest worldwide, with possible consequences including higher rates of late-detected

  10. Non-Invasive Detection of Respiration and Heart Rate with a Vehicle Seat Sensor.

    Science.gov (United States)

    Wusk, Grace; Gabler, Hampton

    2018-05-08

    This study demonstrates the feasibility of using a seat sensor designed for occupant classification from a production passenger vehicle to measure an occupant’s respiration rate (RR) and heart rate (HR) in a laboratory setting. Relaying occupant vital signs after a crash could improve emergency response by adding a direct measure of the occupant state to an Advanced Automatic Collision Notification (AACN) system. Data was collected from eleven participants with body weights ranging from 42 to 91 kg using a Ford Mustang passenger seat and seat sensor. Using a ballistocardiography (BCG) approach, the data was processed by time domain filtering and frequency domain analysis using the fast Fourier transform to yield RR and HR in a 1-min sliding window. Resting rates over the 30-min data collection and continuous RR and HR signals were compared to laboratory physiological instruments using the Bland-Altman approach. Differences between the seat sensor and reference sensor were within 5 breaths per minute for resting RR and within 15 beats per minute for resting HR. The time series comparisons for RR and HR were promising with the frequency analysis technique outperforming the peak detection technique. However, future work is necessary for more accurate and reliable real-time monitoring of RR and HR outside the laboratory setting.

  11. Heart rate detection from single-foot plantar bioimpedance measurements in a weighing scale.

    Science.gov (United States)

    Diaz, Delia H; Casas, Oscar; Pallas-Areny, Ramon

    2010-01-01

    Electronic bathroom scales are an easy-to-use, affordable mean to measure physiological parameters in addition to body weight. They have been proposed to obtain the ballistocardiogram (BCG) and derive from it the heart rate, cardiac output and systolic blood pressure. Therefore, weighing scales may suit intermittent monitoring in e-health and patient screening. Scales intended for bioelectrical impedance analysis (BIA) have also been proposed to estimate the heart rate by amplifying the pulsatile impedance component superimposed on the basal impedance. However, electronic weighing scales cannot easily obtain the BCG from people that have a single leg neither are bioimpedance measurements between both feet recommended for people wearing a pacemaker or other electronic implants, neither for pregnant women. We propose a method to detect the heart rate (HR) from bioimpedance measured in a single foot while standing on an bathroom weighting scale intended for BIA. The electrodes built in the weighing scale are used to apply a 50 kHz voltage between the outer electrode pair and to measure the drop in voltage across the inner electrode pair. The agreement with the HR simultaneously obtained from the ECG is excellent. We have also compared the drop in voltage across the waist and the thorax with that obtained when measuring bioimpedance between both feet to compare the possible risk of the proposed method to that of existing BIA scales.

  12. Rate adaptive multilevel coded modulation with high coding gain in intensity modulation direct detection optical communication

    Science.gov (United States)

    Xiao, Fei; Liu, Bo; Zhang, Lijia; Xin, Xiangjun; Zhang, Qi; Tian, Qinghua; Tian, Feng; Wang, Yongjun; Rao, Lan; Ullah, Rahat; Zhao, Feng; Li, Deng'ao

    2018-02-01

    A rate-adaptive multilevel coded modulation (RA-MLC) scheme based on fixed code length and a corresponding decoding scheme is proposed. RA-MLC scheme combines the multilevel coded and modulation technology with the binary linear block code at the transmitter. Bits division, coding, optional interleaving, and modulation are carried out by the preset rule, then transmitted through standard single mode fiber span equal to 100 km. The receiver improves the accuracy of decoding by means of soft information passing through different layers, which enhances the performance. Simulations are carried out in an intensity modulation-direct detection optical communication system using MATLAB®. Results show that the RA-MLC scheme can achieve bit error rate of 1E-5 when optical signal-to-noise ratio is 20.7 dB. It also reduced the number of decoders by 72% and realized 22 rate adaptation without significantly increasing the computing time. The coding gain is increased by 7.3 dB at BER=1E-3.

  13. Opportunistic mammography screening provides effective detection rates in a limited resource healthcare system.

    Science.gov (United States)

    Teh, Yew-Ching; Tan, Gie-Hooi; Taib, Nur Aishah; Rahmat, Kartini; Westerhout, Caroline Judy; Fadzli, Farhana; See, Mee-Hoong; Jamaris, Suniza; Yip, Cheng-Har

    2015-05-15

    Breast cancer is the leading cause of cancer deaths in women world-wide. In low and middle income countries, where there are no population-based mammographic screening programmes, late presentation is common, and because of inadequate access to optimal treatment, survival rates are poor. Mammographic screening is well-studied in high-income countries in western populations, and because it has been shown to reduce breast cancer mortality, it has become part of the healthcare systems in such countries. However the performance of mammographic screening in a developing country is largely unknown. This study aims to evaluate the performance of mammographic screening in Malaysia, a middle income country, and to compare the stage and surgical treatment of screen-detected and symptomatic breast cancer. A retrospective review of 2510 mammograms performed from Jan to Dec 2010 in a tertiary medical centre is carried out. The three groups identified are the routine (opportunistic) screening group, the targeted (high risk) screening group and the diagnostic group. The performance indicators of each group is calculated, and stage at presentation and treatment between the screening and diagnostic group is analyzed. The cancer detection rate in the opportunistic screening group, targeted screening group, and the symptomatic group is 0.5 %, 1.25 % and 26 % respectively. The proportion of ductal carcinoma in situ is 23.1 % in the two screening groups compared to only 2.5 % in the diagnostic group. Among the opportunistic screening group, the cancer detection rate was 0.2 % in women below 50 years old compared to 0.65 % in women 50 years and above. The performance indicators are within international standards. Early-staged breast cancer (Stage 0-2) were 84.6 % in the screening groups compared to 61.1 % in the diagnostic group. From the results, in a setting with resource constraints, targeted screening of high risk individuals will give a higher yield, and if more resources are

  14. Estimating detection rates for the LIGO-Virgo search for gravitational-wave burst counterparts to gamma-ray bursts using inferred local GRB rates

    International Nuclear Information System (INIS)

    Leonor, I; Frey, R; Sutton, P J; Jones, G; Marka, S; Marka, Z

    2009-01-01

    One of the ongoing searches performed using the LIGO-Virgo network of gravitational-wave interferometers is the search for gravitational-wave burst (GWB) counterparts to gamma-ray bursts (GRBs). This type of analysis makes use of GRB time and position information from gamma-ray satellite detectors to trigger the GWB search, and the GWB detection rates possible for such an analysis thus strongly depend on the GRB detection efficiencies of the satellite detectors. Using local GRB rate densities inferred from observations which are found in the science literature, we calculate estimates of the GWB detection rates for different configurations of the LIGO-Virgo network for this type of analysis.

  15. Pericytes limit tumor cell metastasis

    DEFF Research Database (Denmark)

    Xian, Xiaojie; Håkansson, Joakim; Ståhlberg, Anders

    2006-01-01

    Previously we observed that neural cell adhesion molecule (NCAM) deficiency in beta tumor cells facilitates metastasis into distant organs and local lymph nodes. Here, we show that NCAM-deficient beta cell tumors grew leaky blood vessels with perturbed pericyte-endothelial cell-cell interactions...... the microvessel wall. To directly address whether pericyte dysfunction increases the metastatic potential of solid tumors, we studied beta cell tumorigenesis in primary pericyte-deficient Pdgfb(ret/ret) mice. This resulted in beta tumor cell metastases in distant organs and local lymph nodes, demonstrating a role...... and deficient perivascular deposition of ECM components. Conversely, tumor cell expression of NCAM in a fibrosarcoma model (T241) improved pericyte recruitment and increased perivascular deposition of ECM molecules. Together, these findings suggest that NCAM may limit tumor cell metastasis by stabilizing...

  16. Use of dew-point detection for quantitative measurement of sweating rate

    Science.gov (United States)

    Brengelmann, G. L.; Mckeag, M.; Rowell, L. B.

    1975-01-01

    A method of measuring sweat rate (SR) based on detection of dew point (DP) is proposed which has advantages that may be attractive to other laboratories concerned with recording SR from selected areas of skin. It is similar to other methods in that dry gas is passed through a capsule which isolates several square centimeters of skin surface. The difference is in the means of determining how much gaseous water is carried off in the effluent moist gas. The DP detector used is free of the drawbacks of previous devices. DP is obtained through the fundamental technique of determining the temperature at which condensate forms on a mirror. Variations in DP are tracked rapidly, and accurately (+ or - 0.8 C nominal, sensitivity + or - 0.05 C) over a wide range ( -40 C to +50 C) without measurable hysteresis. The detector asembly is rugged and readily opened for cleaning and inspection.

  17. From b → sγ to the LSP detection rates in minimal string unification models

    International Nuclear Information System (INIS)

    Khalil, S.; Masiero, A.; Shafi, Q.

    1997-04-01

    We exploit the measured branching ratio for b → sγ to derive lower limits on the sparticle and Higgs masses in the minimal string unification models. For the LSP ('bino'), chargino and the lightest Higgs, these turn out to be 50, 90 and 75 GeV respectively. Taking account of the upper bounds on the mass spectrum from the LSP relic abundance, we estimate the direct detection rate for the latter to vary from 10 -1 to 10 -4 events/kg/day. The muon flux, produced by neutrinos from the annihilating LSP's, varies in the range 10 -2 - 10 -9 muons/m 2 /day. (author). 26 refs, 9 figs

  18. A Method for Harmonic Sources Detection based on Harmonic Distortion Power Rate

    Science.gov (United States)

    Lin, Ruixing; Xu, Lin; Zheng, Xian

    2018-03-01

    Harmonic sources detection at the point of common coupling is an essential step for harmonic contribution determination and harmonic mitigation. The harmonic distortion power rate index is proposed for harmonic source location based on IEEE Std 1459-2010 in the paper. The method only based on harmonic distortion power is not suitable when the background harmonic is large. To solve this problem, a threshold is determined by the prior information, when the harmonic distortion power is larger than the threshold, the customer side is considered as the main harmonic source, otherwise, the utility side is. A simple model of public power system was built in MATLAB/Simulink and field test results of typical harmonic loads verified the effectiveness of proposed method.

  19. Topic-oriented community detection of rating-based social networks

    Directory of Open Access Journals (Sweden)

    Ali Reihanian

    2016-07-01

    Full Text Available Nowadays, real world social networks contain a vast range of information including shared objects, comments, following information, etc. Finding meaningful communities in this kind of networks is an interesting research area and has attracted the attention of many researchers. The community structure of complex networks reveals both their organization and hidden relations among their constituents. Most of the researches in the field of community detection mainly focus on the topological structure of the network without performing any content analysis. In recent years, a number of researches have proposed approaches which consider both the contents that are interchanged in networks, and the topological structures of the networks in order to find more meaningful communities. In this research, the effect of topic analysis in finding more meaningful communities in social networking sites in which the users express their feelings toward different objects (like movies by means of rating is demonstrated by performing extensive experiments.

  20. Probabilistic pipe fracture evaluations for applications to leak-rate detection

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, S; Wilkowski, G; Ghadiali, N [Battelle Columbus Labs., OH (United States)

    1993-12-31

    Stochastic pipe fracture evaluations are conducted for applications to leak-rate detection. A state-of-the-art review was first conducted to evaluate the adequacy of current deterministic models for thermo-hydraulic and elastic-plastic fracture analyses. Then a new probabilistic model was developed with the above deterministic models for structural reliability analysis of cracked piping systems and statistical characterization of crack morphology parameters, material properties of pipe, and crack location. The proposed models are then applied for computing conditional probability of failure for various nuclear piping systems in BWR and PWR plants. The PRAISE code was not used, and the probabilistic model is based on modern methods of stochastic mechanics, computationally far superior to Monte Carlo and Stratified Sampling methods used in PRAISE. 10 refs., 9 figs., 1 tab.

  1. Probabilistic pipe fracture evaluations for applications to leak-rate detection

    International Nuclear Information System (INIS)

    Rahman, S.; Wilkowski, G.; Ghadiali, N.

    1992-01-01

    Stochastic pipe fracture evaluations are conducted for applications to leak-rate detection. A state-of-the-art review was first conducted to evaluate the adequacy of current deterministic models for thermo-hydraulic and elastic-plastic fracture analyses. Then a new probabilistic model was developed with the above deterministic models for structural reliability analysis of cracked piping systems and statistical characterization of crack morphology parameters, material properties of pipe, and crack location. The proposed models are then applied for computing conditional probability of failure for various nuclear piping systems in BWR and PWR plants. The PRAISE code was not used, and the probabilistic model is based on modern methods of stochastic mechanics, computationally far superior to Monte Carlo and Stratified Sampling methods used in PRAISE. 10 refs., 9 figs., 1 tab

  2. Variable terrestrial GPS telemetry detection rates: Addressing the probability of successful acquisitions

    Science.gov (United States)

    Ironside, Kirsten E.; Mattson, David J.; Choate, David; Stoner, David; Arundel, Terry; Hansen, Jered R.; Theimer, Tad; Holton, Brandon; Jansen, Brian; Sexton, Joseph O.; Longshore, Kathleen M.; Edwards, Thomas C.; Peters, Michael

    2017-01-01

    Studies using global positioning system (GPS) telemetry rarely result in 100% fix success rates (FSR), which may bias datasets because data loss is systematic rather than a random process. Previous spatially explicit models developed to correct for sampling bias have been limited to small study areas, a small range of data loss, or were study-area specific. We modeled environmental effects on FSR from desert to alpine biomes, investigated the full range of potential data loss (0–100% FSR), and evaluated whether animal body position can contribute to lower FSR because of changes in antenna orientation based on GPS detection rates for 4 focal species: cougars (Puma concolor), desert bighorn sheep (Ovis canadensis nelsoni), Rocky Mountain elk (Cervus elaphus nelsoni), and mule deer (Odocoileus hemionus). Terrain exposure and height of over story vegetation were the most influential factors affecting FSR. Model evaluation showed a strong correlation (0.88) between observed and predicted FSR and no significant differences between predicted and observed FSRs using 2 independent validation datasets. We found that cougars and canyon-dwelling bighorn sheep may select for environmental features that influence their detectability by GPS technology, mule deer may select against these features, and elk appear to be nonselective. We observed temporal patterns in missed fixes only for cougars. We provide a model for cougars, predicting fix success by time of day that is likely due to circadian changes in collar orientation and selection of daybed sites. We also provide a model predicting the probability of GPS fix acquisitions given environmental conditions, which had a strong relationship (r 2 = 0.82) with deployed collar FSRs across species.

  3. Detection Rate and Clinical Impact of Respiratory Viruses in Children with Kawasaki Disease

    Directory of Open Access Journals (Sweden)

    Ja Hye Kim

    2012-12-01

    Full Text Available &lt;B&gt;Purpose:&lt;/B&gt; The purpose of this prospective case-control study was to survey the detection rate of respiratory viruses in children with Kawasaki disease (KD by using multiplex reverse transcriptasepolymerase chain reaction (RT-PCR, and to investigate the clinical implications of the prevalence of respiratory viruses during the acute phase of KD. &lt;B&gt;Methods:&lt;/B&gt; RT-PCR assays were carried out to screen for the presence of respiratory syncytial virus A and B, adenovirus, rhinovirus, parainfluenza viruses 1 to 4, influenza virus A and B, metapneumovirus, bocavirus, coronavirus OC43/229E and NL63, and enterovirus in nasopharyngeal secretions of 55 KD patients and 78 control subjects. &lt;B&gt;Results:&lt;/B&gt; Virus detection rates in KD patients and control subjects were 32.7% and 30.8%, respectively (P=0.811. However, there was no significant association between the presence of any of the 15 viruses and the incidence of KD. Comparisons between the 18 patients with positive RT-PCR results and the other 37 KD patients revealed no significant differences in terms of clinical findings (including the prevalence of incomplete presentation of the disease and coronary artery diameter. &lt;B&gt;Conclusion:&lt;/B&gt; A positive RT-PCR for currently epidemic respiratory viruses should not be used as an evidence against the diagnosis of KD. These viruses were not associated with the incomplete presentation of KD and coronary artery dilatation.

  4. Delay in diabetic retinopathy screening increases the rate of detection of referable diabetic retinopathy.

    Science.gov (United States)

    Scanlon, P H; Aldington, S J; Stratton, I M

    2014-04-01

    To assess whether there is a relationship between delay in retinopathy screening after diagnosis of type 2 diabetes and level of retinopathy detected. Patients were referred from 88 primary care practices to an English National Health Service diabetic eye screening programme. Data for screened patients were extracted from the primary care databases using semi-automated data collection algorithms supplemented by validation processes. The programme uses two-field mydriatic digital photographs graded by a quality assured team. Data were available for 8183 screened patients with diabetes newly diagnosed in 2005, 2006 or 2007. Only 163 with type 1 diabetes were identified and were insufficient for analysis. Data were available for 8020 with newly diagnosed type 2 diabetes. Of these, 3569 were screened within 6 months, 2361 between 6 and 11 months, 1058 between 12 and 17 months, 366 between 18 and 23 months, 428 between 24 and 35 months, and 238 at 3 years or more after diagnosis. There were 5416 (67.5%) graded with no retinopathy, 1629 (20.3%) with background retinopathy in one eye, 753 (9.4%) with background retinopathy in both eyes and 222 (2.8%) had referable diabetic retinopathy. There was a significant trend (P = 0.0004) relating time from diagnosis to screening detecting worsening retinopathy. Of those screened within 6 months of diagnosis, 2.3% had referable retinopathy and, 3 years or more after diagnosis, 4.2% had referable retinopathy. The rate of detection of referable diabetic retinopathy is elevated in those who were not screened promptly after diagnosis of type 2 diabetes. © 2013 The Authors. Diabetic Medicine published by John Wiley & Sons Ltd on behalf of Diabetes UK.

  5. A Longitudinal Study of Adenoma Detection Rate in Gastroenterology Fellowship Training.

    Science.gov (United States)

    Gianotti, Robert J; Oza, Sveta Shah; Tapper, Elliot B; Kothari, Darshan; Sheth, Sunil G

    2016-10-01

    Current guidelines suggest that a gastroenterology fellow in training needs to perform 140 colonoscopies to achieve competency. Data are limited regarding adenoma detection rate (ADR) in fellowship. To assess how fellow ADR correlates with number of colonoscopies performed. We performed a retrospective study examining consecutive colonoscopies performed by gastroenterology fellows. Fellow ADR before and after the 140 procedure benchmark was compared to colonoscopies performed by attending only with whom these fellows trained. A threshold for ideal procedure count was performed using ROC analysis. We analyzed 2021 average-risk colonoscopies performed by 10 gastroenterology fellows under the supervision of an attending physician. When fellows had performed 140 colonoscopies under attending supervision (p = 0.02). The ADR of fellows who had performed >140 colonoscopies under attending supervision was greater than that of attending-only colonoscopies (36 vs. 25 %, p 325 (male patients) and 539 (female patients) colonoscopies was determined to be ideal for achieving adequate ADR based on ROC analysis. Our data suggest that ADR increases after fellows perform >140 colonoscopies under attending supervision, and thereafter surpasses the ADR of attending-only colonoscopies. Some of the differences may be driven by detection of small adenomas. The findings of this study suggest that a higher threshold for number of colonoscopies performed under attending supervision may be needed to achieve adequate ADR during fellowship prior to independent practice.

  6. Fiber optic sensor based on reflectivity configurations to detect heart rate

    Science.gov (United States)

    Yunianto, M.; Marzuki, A.; Riyatun, R.; Lestari, D.

    2016-11-01

    Research of optical fiber-based heart rate detection sensor has been conducted using the reflection configurationon the thorax motion modified. Optical fiber used in this research was Plastic Optical Fiber (POF) with a diameter of 0.5. Optical fiber system is made with two pieces of fiber, the first fiber is to serve as a transmitter transmitting light from the source to the reflector membrane, the second fiber serves as a receiver. One of the endsfrom the two fibersis pressed and positioned perpendicular of reflector membrane which is placed on the surface of the chest. The sensor works on the principle of intensity changes captured by the receiver fiber when the reflector membrane gets the vibe from the heart. The light source used is in the form of Light Emitting Diode (LED) and Light Dependent Resistor (LDR) as a light sensor. Variations are performed on the reflector membrane diameter. The light intensity received by the detector increases along with the increasing width of the reflector membrane diameter. The results show that this sensor can detect the harmonic peak at a frequency of 1.5 Hz; 7.5 Hz; 10.5 Hz; and 22.5 Hz in a healthy human heart with an average value of Beat Per Minute (BPM) by 78 times, a prototype sensor that is made can work and function properly.

  7. Risk of intracranial hemorrhage and cerebrovascular accidents in non-small cell lung cancer brain metastasis patients.

    Science.gov (United States)

    Srivastava, Geetika; Rana, Vishal; Wallace, Suzy; Taylor, Sarah; Debnam, Matthew; Feng, Lei; Suki, Dima; Karp, Daniel; Stewart, David; Oh, Yun

    2009-03-01

    Brain metastases confer significant morbidity and a poorer survival in non-small cell lung cancer (NSCLC). Vascular endothelial growth factor-targeted antiangiogenic therapies (AAT) have demonstrated benefit for patients with metastatic NSCLC and are expected to directly inhibit the pathophysiology and morbidity of brain metastases, yet patients with brain metastases have been excluded from most clinical trials of AAT for fear of intracranial hemorrhage (ICH). The underlying risk of ICH from NSCLC brain metastases is low, but needs to be quantitated to plan clinical trials of AAT for NSCLC brain metastases. Data from MD Anderson Cancer Center Tumor Registry and electronic medical records from January 1998 to March 2006 was interrogated. Two thousand one hundred forty-three patients with metastatic NSCLC registering from January 1998 to September 2005 were followed till March 2006. Seven hundred seventy-six patients with and 1,367 patients without brain metastases were followed till death, date of ICH, or last date of study, whichever occurred first. The incidence of ICH seemed to be higher in those with brain metastasis compared with those without brain metastases, in whom they occurred as result of cerebrovascular accidents. However, the rates of symptomatic ICH were not significantly different. All ICH patients with brain metastasis had received radiation therapy for them and had been free of anticoagulation. Most of the brain metastasis-associated ICH's were asymptomatic, detected during increased radiologic surveillance. The rates of symptomatic ICH, or other cerebrovascular accidents in general were similar and not significantly different between the two groups. In metastatic NSCLC patients, the incidence of spontaneous ICH appeared to be higher in those with brain metastases compared with those without, but was very low in both groups without a statistically significant difference. These data suggest a minimal risk of clinically significant ICH for NSCLC

  8. Active Tobacco Smoking and Distant Metastasis in Patients With Oropharyngeal Cancer

    International Nuclear Information System (INIS)

    McBride, Sean M.; Ali, Nawal N.; Margalit, Danielle N.; Chan, Annie W.

    2012-01-01

    Purpose: Distant metastasis is the site of first relapse in approximately one-third of patients with locally advanced oropharyngeal carcinoma, irrespective of human papillomavirus status. Yet the risk factors associated with distant metastasis are not well characterized. We sought to characterize the relationship between smoking status and distant metastasis. Methods and Materials: We evaluated the association between tobacco smoking status and distant metastasis in a retrospective cohort study of 132 patients who underwent definitive radiation therapy and chemotherapy for Stage III–IVA/B oropharyngeal cancer. Information on tobacco smoking was prospectively collected by patient questionnaires and physician notes at the time of diagnosis. Thirty-three percent of the patients were nonsmokers, 51% were former smokers, 16% were active smokers. The cumulative lifetime tobacco smoking in pack-years was 20 (range, 0–150). Results: With a median follow-up time of 52 months, the overall rate of distant metastasis at 4 years was 8%. Distant metastasis was the most common first site of relapse, occurring in 56% of the patients with recurrences. Active smokers had higher rates of distant metastasis than non-active smokers (including never- and former smokers; 31% vs. 4%, p 20 and ≤20 (10% vs. 4%, p = 0.19). In univariate analysis, active smoking (p = 0.0004) and N category (p = 0.009) were predictive of increased risk of distant metastasis. In multivariate analysis, active smoking was the most significant predictive factor for increased risk of distant metastasis (hazard ratio, 12.7, p < 0.0001). Conclusions: This study identified a strong association between active smoking and distant metastasis in patients with oropharyngeal cancer.

  9. Early detection of left ventricular dysfunction in asymptomatic diabetic patient using strain and strain rate echocardiographic imaging

    Directory of Open Access Journals (Sweden)

    Rania Gaber

    2014-03-01

    Conclusion: Type 2 diabetes mellitus deteriorate both LV systolic and diastolic performance. Strain and strain rate by tissue Doppler Imaging is superior to conventional Doppler in early detection and evaluation of systolic and diastolic dysfunction in type 2 diabetic patients.

  10. Time of day variation in polyp detection rate for colonoscopies performed on a 3-hour shift schedule.

    LENUS (Irish Health Repository)

    Munson, Gregory W

    2011-03-01

    Recent research suggests that the colonoscopy polyp detection rate (PDR) varies by time of day, possibly because of endoscopist fatigue. Mayo Clinic Rochester (MCR) schedules colonoscopies on 3-hour shifts, which should minimize fatigue.

  11. Standard and Nonstandard Neutrino-Nucleus Reactions Cross Sections and Event Rates to Neutrino Detection Experiments

    Directory of Open Access Journals (Sweden)

    D. K. Papoulias

    2015-01-01

    Full Text Available In this work, we explore ν-nucleus processes from a nuclear theory point of view and obtain results with high confidence level based on accurate nuclear structure cross sections calculations. Besides cross sections, the present study includes simulated signals expected to be recorded by nuclear detectors and differential event rates as well as total number of events predicted to be measured. Our original cross sections calculations are focused on measurable rates for the standard model process, but we also perform calculations for various channels of the nonstandard neutrino-nucleus reactions and come out with promising results within the current upper limits of the corresponding exotic parameters. We concentrate on the possibility of detecting (i supernova neutrinos by using massive detectors like those of the GERDA and SuperCDMS dark matter experiments and (ii laboratory neutrinos produced near the spallation neutron source facilities (at Oak Ridge National Lab by the COHERENT experiment. Our nuclear calculations take advantage of the relevant experimental sensitivity and employ the severe bounds extracted for the exotic parameters entering the Lagrangians of various particle physics models and specifically those resulting from the charged lepton flavour violating μ-→e- experiments (Mu2e and COMET experiments.

  12. Improved detection of congestive heart failure via probabilistic symbolic pattern recognition and heart rate variability metrics.

    Science.gov (United States)

    Mahajan, Ruhi; Viangteeravat, Teeradache; Akbilgic, Oguz

    2017-12-01

    A timely diagnosis of congestive heart failure (CHF) is crucial to evade a life-threatening event. This paper presents a novel probabilistic symbol pattern recognition (PSPR) approach to detect CHF in subjects from their cardiac interbeat (R-R) intervals. PSPR discretizes each continuous R-R interval time series by mapping them onto an eight-symbol alphabet and then models the pattern transition behavior in the symbolic representation of the series. The PSPR-based analysis of the discretized series from 107 subjects (69 normal and 38 CHF subjects) yielded discernible features to distinguish normal subjects and subjects with CHF. In addition to PSPR features, we also extracted features using the time-domain heart rate variability measures such as average and standard deviation of R-R intervals. An ensemble of bagged decision trees was used to classify two groups resulting in a five-fold cross-validation accuracy, specificity, and sensitivity of 98.1%, 100%, and 94.7%, respectively. However, a 20% holdout validation yielded an accuracy, specificity, and sensitivity of 99.5%, 100%, and 98.57%, respectively. Results from this study suggest that features obtained with the combination of PSPR and long-term heart rate variability measures can be used in developing automated CHF diagnosis tools. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Routine perinatal and paediatric post-mortem radiography: detection rates and implications for practice

    Energy Technology Data Exchange (ETDEWEB)

    Arthurs, Owen J. [NHS Foundation Trust, Department of Radiology Great Ormond Street Hospital for Children, London (United Kingdom); University College London, Institute of Child Health, London (United Kingdom); Calder, Alistair D. [NHS Foundation Trust, Department of Radiology Great Ormond Street Hospital for Children, London (United Kingdom); Kiho, Liina [Camelia Botnar Laboratories Great Ormond Street Hospital for Children, Department of Paediatric Pathology, London (United Kingdom); Taylor, Andrew M. [Great Ormond Street Hospital for Children, Cardiorespiratory Unit, London (United Kingdom); UCL Institute of Cardiovascular Science, London (United Kingdom); University College London, Institute of Child Health, London (United Kingdom); Sebire, Neil J. [Camelia Botnar Laboratories Great Ormond Street Hospital for Children, Department of Paediatric Pathology, London (United Kingdom); University College London, Institute of Child Health, London (United Kingdom)

    2014-03-15

    Routine perinatal and paediatric post-mortem plain radiography allows for the diagnosis and assessment of skeletal dysplasias, fractures and other bony abnormalities. The aim of this study was to review the diagnostic yield of this practice. We identified 1,027 cases performed in a single institution over a 21/2-year period, including babygrams (whole-body examinations) and full skeletal surveys. Images were reported prior to autopsy in all cases. Radiology findings were cross-referenced with the autopsy findings using an autopsy database. We scored each case from 0 to 4 according to the level of diagnostic usefulness. The overall abnormality rate was 126/1,027 (12.3%). There was a significantly higher rate of abnormality when a skeletal survey was performed (18%) rather than a babygram (10%; P < 0.01); 90% (665/739) of babygrams were normal. Of the 74 abnormal babygrams, we found 33 incidental non-contributory cases, 19 contributory, 20 diagnostic, and 2 false-positive cases. There were only 2 cases out of 739 (0.27%) in whom routine post-mortem imaging identified potentially significant abnormalities that would not have been detected if only selected imaging had been performed. A policy of performing selected, rather than routine, foetal post-mortem radiography could result in a significant cost saving. Routine post-mortem paediatric radiography in foetuses and neonates is neither diagnostically useful nor cost-effective. A more evidence-based, selective protocol should yield significant cost savings. (orig.)

  14. Routine perinatal and paediatric post-mortem radiography: detection rates and implications for practice

    International Nuclear Information System (INIS)

    Arthurs, Owen J.; Calder, Alistair D.; Kiho, Liina; Taylor, Andrew M.; Sebire, Neil J.

    2014-01-01

    Routine perinatal and paediatric post-mortem plain radiography allows for the diagnosis and assessment of skeletal dysplasias, fractures and other bony abnormalities. The aim of this study was to review the diagnostic yield of this practice. We identified 1,027 cases performed in a single institution over a 21/2-year period, including babygrams (whole-body examinations) and full skeletal surveys. Images were reported prior to autopsy in all cases. Radiology findings were cross-referenced with the autopsy findings using an autopsy database. We scored each case from 0 to 4 according to the level of diagnostic usefulness. The overall abnormality rate was 126/1,027 (12.3%). There was a significantly higher rate of abnormality when a skeletal survey was performed (18%) rather than a babygram (10%; P < 0.01); 90% (665/739) of babygrams were normal. Of the 74 abnormal babygrams, we found 33 incidental non-contributory cases, 19 contributory, 20 diagnostic, and 2 false-positive cases. There were only 2 cases out of 739 (0.27%) in whom routine post-mortem imaging identified potentially significant abnormalities that would not have been detected if only selected imaging had been performed. A policy of performing selected, rather than routine, foetal post-mortem radiography could result in a significant cost saving. Routine post-mortem paediatric radiography in foetuses and neonates is neither diagnostically useful nor cost-effective. A more evidence-based, selective protocol should yield significant cost savings. (orig.)

  15. [An experimental study on the Chinese lung adenocarcinoma cell clone CPA-Yang1-BR with brain metastasis potency in nude mice and in vivo imaging research].

    Science.gov (United States)

    Lei, Bei; Cao, Jie; Shen, Jie; Zhao, Lanxiang; Liang, Sheng; Meng, Qinggang; Xie, Wenhui; Yang, Shunfang

    2013-08-20

    Lung cancer is the leading cause of cancer-related death in men and women. It is also the most common cause of brain metastases. A brain metastasis model is difficult to be established because of the presence of the blood-brain barrier (BBB) and the lack of optimal methods for detecting brain metastasis in nude mice. Thus, the establishment of a Chinese lung adenocarcinoma cell line and its animal model with brain metastasis potency and in vivo research is of great significance. CPA-Yang1 cells were obtained from a patient with human lung adenocarcinoma by lentiviral vector-mediated transfection of green fluorescence protein. Intracardiac inoculation of the cells was performed in nude mice, and brain metastatic lesions were detected using micro ¹⁸F FDG-PET/CT scanners, small animal in vivo imaging system for fluorescence, radionuclide and X ray fused imaging, magnetic resonance imaging (MRI) with sense body detection, and resection. The samples were divided into two parts for cell culture and histological diagnosis. The process was repeated in vivo and in vitro for four cycles to obtain a novel cell clone, CPA-Yang1-BR. A novel cell clone, CPA-Yang1-BR, was obtained with a brain metastatic rate of 50%. The use of MRI for the detection of brain metastases has obvious advantages. An experimental Chinese lung adenocarcinoma cell clone (CPA-Yang1-BR) and its animal model with brain metastasis potency in nude mice were established. MRI with sense body or micro MRI may be used as a sensitive, accurate, and noninvasive method to detect experimental brain metastases in intact live immunodeficient mice. The results of this study may serve as a technical platform for brain metastases from lung adenocarcinoma.

  16. Influence of depth, time and human activity on detection rate of acoustic tags: a case study on two fish farms.

    Science.gov (United States)

    Otterå, H; Skilbrei, O T

    2016-03-01

    The detection rates of stationary acoustic transmitters deployed at three depths on two Atlantic salmon Salmo salar cage farms for c. 2 months were investigated. Deployment depth, time of day, day of the year and specific incidences at the farm substantially affected the rate of signal detection by the receiver. © 2016 The Authors. Journal of Fish Biology published by John Wiley & Sons Ltd on behalf of The Fisheries Society of the British Isles.

  17. Three-minute constant rate step test for detecting exertional dyspnea relief after bronchodilation in COPD

    Directory of Open Access Journals (Sweden)

    Borel B

    2016-11-01

    Full Text Available Benoit Borel,1,2 Courtney A Wilkinson-Maitland,3 Alan Hamilton,4 Jean Bourbeau,5 Hélène Perrault,6 Dennis Jensen,3,5,7 François Maltais2 1Laboratoire HAVAE, Université de Limoges, Limoges, France; 2Centre de Recherche, Institut Universitaire de Cardiologie et de Pneumologie de Québec, Université Laval, Québec, 3Clinical Exercise and Respiratory Physiology Laboratory, Department of Kinesiology and Physical Education, McGill University, Montréal, QC, 4Boehringer Ingelheim (Canada Limited, Burlington, ON, 5Respiratory Epidemiology and Clinical Research Unit, Montreal Chest Institute, McGill University Health Center, Montreal, QC, 6Faculty of Health Sciences, University of Ottawa, Ottawa, ON, 7Translational Research in Respiratory Diseases Program, Research Institute of the McGill University Health Centre, Montreal, QC, Canada Background: The aim of this study was to evaluate the responsiveness of the 3-minute constant rate step test (3-MST to detect the relief of exertional dyspnea (respiratory discomfort after acute bronchodilation in COPD patients. Patients and methods: A total of 40 patients with moderate-to-severe COPD (mean forced expiratory volume in 1 second: 45.7 (±14.7, % predicted performed four 3-MSTs at randomly assigned stepping rates of 14, 16, 20 and 24 steps/min after inhalation of nebulized ipratropium bromide (500 µg/salbutamol (2.5 mg and saline placebo, which were randomized to order. Patients rated their intensity of perceived dyspnea at the end of each 3-MST using Borg 0–10 category ratio scale. Results: A total of 37 (92.5%, 36 (90%, 34 (85% and 27 (67.5% patients completed all 3 minutes of exercise at 14, 16, 20 and 24 steps/min under both treatment conditions, respectively. Compared with placebo, ipratropium bromide/salbutamol significantly decreased dyspnea at the end of the third minute of exercise at 14 steps/min (by 0.6±1.0 Borg 0–10 scale units, P<0.01 and 16 steps/min (by 0.7±1.3 Borg 0–10 scale

  18. Analysis of acoustic cardiac signals for heart rate variability and murmur detection using nonnegative matrix factorization-based hierarchical decomposition

    DEFF Research Database (Denmark)

    Shah, Ghafoor; Koch, Peter; Papadias, Constantinos B.

    2014-01-01

    The detection of heart rate variability (HRV) via cardiac auscultation examination can be a useful and inexpensive tool which, however, is challenging in the presence of pathological signals and murmurs. The aim of this research is to analyze acoustic cardiac signals for HRV and murmur detection...

  19. Positive predictive value of device-detected atrial high-rate episodes at different rates and durations

    DEFF Research Database (Denmark)

    Kaufman, Elizabeth S; Israel, Carsten W; Nair, Girish M

    2012-01-01

    BACKGROUND: Pacemakers can automatically identify and catalog atrial high-rate episodes (AHREs). While most AHREs represent true atrial tachyarrhythmia/atrial fibrillation (AT/AF), a review of stored electrograms suggests that a substantial proportion do not. As AHREs may lead to the initiation o...

  20. Multi-disciplinary team for early gastric cancer diagnosis improves the detection rate of early gastric cancer.

    Science.gov (United States)

    Di, Lianjun; Wu, Huichao; Zhu, Rong; Li, Youfeng; Wu, Xinglong; Xie, Rui; Li, Hongping; Wang, Haibo; Zhang, Hua; Xiao, Hong; Chen, Hui; Zhen, Hong; Zhao, Kui; Yang, Xuefeng; Xie, Ming; Tuo, Bigung

    2017-12-06

    Gastric cancer is a frequent malignant tumor worldwide and its early detection is crucial for curing the disease and enhancing patients' survival rate. This study aimed to assess whether the multi-disciplinary team (MDT) can improve the detection rate of early gastric cancer (EGC). The detection rate of EGC at the Digestive Endoscopy Center, Affiliated Hospital, Zunyi Medical College, China between September 2013 and September 2015 was analyzed. MDT for the diagnosis of EGC in the hospital was established in September 2014. The study was divided into 2 time periods: September 1, 2013 to August 31, 2014 (period 1) and September 1, 2014 to September 1, 2015 (period 2). A total of 60,800 patients' gastroscopies were performed during the two years. 61 of these patients (0.1%) were diagnosed as EGC, accounting for 16.44% (61/371) of total patients with gastric cancer. The EGC detection rate before MDT (period 1) was 0.05% (16/29403), accounting for 9.09% (16/176) of total patients with gastric cancer during this period. In comparison, the EGC detection rate during MDT (period 2) was 0.15% (45/31397), accounting for 23% (45/195) of total patients with gastric cancer during this period (P cooperation with Department of Pathology (OR = 10.1, 95% CI 2.39-43.3, P < 0.05). MDT could improve the endoscopic detection rate of EGC.

  1. Thyroid Metastasis from Breast Carcinoma Accompanied by Papillary Thyroid Carcinoma

    Directory of Open Access Journals (Sweden)

    Song-I Yang

    2014-07-01

    Full Text Available Metastasis to the thyroid gland is very rare. Recently, we experienced a case of thyroid metastasis from breast cancer accompanying a papillary thyroid. A 51-year-old female patient presented with a palpated lymph node on her left lateral neck. The patient had undergone a left modified radical mastectomy followed by chemotherapy and hormonal therapy 12 years prior. Ultrasonography of the neck revealed a malignant looking nodule at the left thyroid lobe, measuring 0.9 × 0.9 cm, and several cystic nodules at the right thyroid lobe. Ultrasonography of the neck additionally revealed a malignant looking lymph node at the right level VI. Fine-needle aspiration of the left thyroid lobe resulted in a diagnosis of papillary thyroid carcinoma and that of the right level VI in Hurthle cell lesion. The patient had a total thyroidectomy with selective dissection of the left neck node. Pathologic assessment of the specimen revealed metastatic carcinoma from the breast carcinoma and papillary thyroid carcinoma. Although the thyroid gland is highly vascularized, metastasis of malignant tumors to the thyroid is relatively rare and detection of metastasis shows a low frequency. So a careful evaluation of thyroid tumor should be considered in a patient with a history of other malignancy.

  2. Tungsten Targets the Tumor Microenvironment to Enhance Breast Cancer Metastasis

    Science.gov (United States)

    Bolt, Alicia M.; Sabourin, Valérie; Molina, Manuel Flores; Police, Alice M.; Negro Silva, Luis Fernando; Plourde, Dany; Lemaire, Maryse; Ursini-Siegel, Josie; Mann, Koren K.

    2015-01-01

    The number of individuals exposed to high levels of tungsten is increasing, yet there is limited knowledge of the potential human health risks. Recently, a cohort of breast cancer patients was left with tungsten in their breasts following testing of a tungsten-based shield during intraoperative radiotherapy. While monitoring tungsten levels in the blood and urine of these patients, we utilized the 66Cl4 cell model, in vitro and in mice to study the effects of tungsten exposure on mammary tumor growth and metastasis. We still detect tungsten in the urine of patients’ years after surgery (mean urinary tungsten concentration at least 20 months post-surgery = 1.76 ng/ml), even in those who have opted for mastectomy, indicating that tungsten does not remain in the breast. In addition, standard chelation therapy was ineffective at mobilizing tungsten. In the mouse model, tungsten slightly delayed primary tumor growth, but significantly enhanced lung metastasis. In vitro, tungsten did not enhance 66Cl4 proliferation or invasion, suggesting that tungsten was not directly acting on 66Cl4 primary tumor cells to enhance invasion. In contrast, tungsten changed the tumor microenvironment, enhancing parameters known to be important for cell invasion and metastasis including activated fibroblasts, matrix metalloproteinases, and myeloid-derived suppressor cells. We show, for the first time, that tungsten enhances metastasis in an animal model of breast cancer by targeting the microenvironment. Importantly, all these tumor microenvironmental changes are associated with a poor prognosis in humans. PMID:25324207

  3. Testicular Metastasis of Prostate Cancer: A Case Report

    Directory of Open Access Journals (Sweden)

    Ayumu Kusaka

    2014-09-01

    Full Text Available The incidence of secondary neoplasms of the testis during autopsies is approximately 2.5%. Although most secondary testicular metastases are due to prostate cancer, only a few patients with prostate cancer have clinically manifested testicular metastasis. We report the case of a prostate cancer patient with testicular metastasis who was diagnosed after the presence of a palpable mass in the right testis. A 56-year-old Japanese male presented to our hospital with an elevated serum prostate-specific antigen (PSA level of 137 ng/ml. He was diagnosed with stage IV (T3N1M1b prostate cancer and received androgen deprivation therapy, followed by various hormonal manipulations. His serum PSA level was undetectable for 1 year. No distant metastases were detected during imaging examinations. He received radiation therapy; however, his serum PSA level increased gradually. Four months later, he presented with right testicular swelling. Computed tomography revealed a heterogenous mass in the right testis and a right high inguinal orchiectomy was performed. Histopathological analysis showed that the right testis was infiltrated with metastatic adenocarcinoma with a Gleason score of 8. This is a rare case of right testicular metastasis in a patient with prostate cancer. Testicular metastasis of prostate cancer can be aggressive and metastasize.

  4. False discovery rate control incorporating phylogenetic tree increases detection power in microbiome-wide multiple testing.

    Science.gov (United States)

    Xiao, Jian; Cao, Hongyuan; Chen, Jun

    2017-09-15

    Next generation sequencing technologies have enabled the study of the human microbiome through direct sequencing of microbial DNA, resulting in an enormous amount of microbiome sequencing data. One unique characteristic of microbiome data is the phylogenetic tree that relates all the bacterial species. Closely related bacterial species have a tendency to exhibit a similar relationship with the environment or disease. Thus, incorporating the phylogenetic tree information can potentially improve the detection power for microbiome-wide association studies, where hundreds or thousands of tests are conducted simultaneously to identify bacterial species associated with a phenotype of interest. Despite much progress in multiple testing procedures such as false discovery rate (FDR) control, methods that take into account the phylogenetic tree are largely limited. We propose a new FDR control procedure that incorporates the prior structure information and apply it to microbiome data. The proposed procedure is based on a hierarchical model, where a structure-based prior distribution is designed to utilize the phylogenetic tree. By borrowing information from neighboring bacterial species, we are able to improve the statistical power of detecting associated bacterial species while controlling the FDR at desired levels. When the phylogenetic tree is mis-specified or non-informative, our procedure achieves a similar power as traditional procedures that do not take into account the tree structure. We demonstrate the performance of our method through extensive simulations and real microbiome datasets. We identified far more alcohol-drinking associated bacterial species than traditional methods. R package StructFDR is available from CRAN. chen.jun2@mayo.edu. Supplementary data are available at Bioinformatics online. © The Author (2017). Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  5. The use of high definition colonoscopy versus standard definition: does it affect polyp detection rate?

    Science.gov (United States)

    Richardson, John; Thaventhiran, Anthony; Mackenzie, Hugh; Stubbs, Benjamin

    2017-11-03

    Polyp detection rate (PDR) during lower gastrointestinal endoscopy (LGIE) is of clinical importance. Detecting adenomatous polyps early in the adenoma-carcinoma sequence can halt disease progression, enabling treatment at a favourable stage. High definition colonoscopy (HDC) has been used in our hospital alongside standard definition equipment since 2011. We aim to determine what affect the use of HDC has on PDR. Post-hoc analysis of a prospectively maintained database on all patients undergoing LGIE was performed (01/01/2012-31/12/2015), n = 15,448. Analysis tested the primary outcome of HD's effect on PDR across LGIE and secondary outcome stratified this by endoscopist group (Physician (PE), Surgeon (SE) and Nurse Endoscopist (NE)). Of 15,448 patients, 1353 underwent HDC. Unmatched analysis showed PDR increased by 5.3% in this group (p < 0.001). Matched analysis considered 2288 patients from the total cohort (1144 HDC) and showed an increase of 1% in PDR with HDC (p = 0.578). Further unmatched analysis stratified by endoscopist groups showed a PDR increase of 1.8% (p = 0.375), 5.4% (p = 0.008) and 4.6% (p = 0.021) by PE, SE and NE respectively. Matched analysis demonstrated an increase of 1% (p = 0.734) and 1.5% (p = 0.701) amongst PE and NE, with a decrease of 0.6% (p = 0.883) by SE. The introduction of HDC increased PDR across all LGIE in our hospital, though this was not clinically significant. This marginal benefit was present across all endoscopist groups with no group benefiting over another in matched analysis.

  6. Alveolar Soft Part Sarcoma Presenting as Hypervascular Adrenal Metastasis

    OpenAIRE

    Goroshi, Manjunath; Lila, Anurag R.; Bandgar, Tushar; Shah, Nalini S.

    2018-01-01

    Hypervascular adrenal masses include pheochromocytoma, metastases caused by clear renal cell carcinoma/hepatocellular carcinoma. Alveolar soft part sarcoma (ASPS) causing hypervascular metastases is not described in the literature. Here, we describe the first case of ASPS presenting as hypervascular metastasis. Our case was a 23-year-old male incidentally detected right adrenal mass during the evaluation of pain in the abdomen. On computed tomography (CT), adrenal mass showed bright enhanceme...

  7. Mixed adenoneuroendocrine carcinoma with brain metastasis

    Directory of Open Access Journals (Sweden)

    Xiao-ling YAN

    2015-05-01

    Full Text Available Objective To study clinicopathological features, diagnosis, differential diagnosis and prognosis of mixed adenoneuroendocrine carcinoma (MANEC.  Methods One case of MANEC with brain metastasis was reported focusing on the following aspects: clinical manifestations, histopathological features and immunophenotypes, and the relevant literatures were reviewed.  Results A 35-year-old male presented headache and vomiting, and his head CT scan showed a lesion located in the right temporal lobe. The tumor was detected after separating the cerebral cortex during the surgery. The tumor diameter was 3 cm. The tumor was soft and rubbery with ill-defined margins, and rich in blood supply. Under optical microscopy, the tumor was consisted of small round cells of the same size, with focal tumor cells arranged around blood vessels in a pseudorosette manner or papillary manner with brisk mitotic activity. The boundary between tumor and brain tissue was ill-defined. By using immunohistochemical staining, the tumor cells were diffusely positive for synaptophysin (Syn and CD56, and negative for glial fibrillary acidic protein (GFAP, pan cytokeratin (PCK, CD3, CD20, vimentin (Vim, leukocyte common antigen (LCA, thyroid transcription factor-1 (TTF-1, S-100 protein (S-100, neurofilament (NF, nestin (Nes, CK5/6, CK8/18 and CD99. Ki-67 labeling index was about 62%. Sigmoidoscopy was performed later in another hospital and showed a mass in the patient's colon. The colon tumor was biphasic in appearance, and was consisted of two distinct components: isomorphic small round cells and low-middle differentiated adenocarcinoma cells. The small round tumor cells were diffusely positive for Syn and CD56, and negative for PCK. The adenocarcinoma cells showed opposite results.  Conclusions MANEC is a rare tumor, which is defined in 2010 by WHO Classification of Digestive, and to the best of our knowledge, MANEC of the colon with brain metastasis has never been described

  8. Impact of splenic hilar lymph node metastasis on prognosis in patients with advanced gastric cancer.

    Science.gov (United States)

    Son, Taeil; Kwon, In Gyu; Lee, Joong Ho; Choi, Youn Young; Kim, Hyoung-Il; Cheong, Jae-Ho; Noh, Sung Hoon; Hyung, Woo Jin

    2017-10-13

    Impact of splenic hilar LN dissection during total gastrectomy for proximal advanced gastric cancer is controversial. The objective of this study was to assess the impact on prognosis of splenic hilar lymph node(LN) metastasis compared to that of metastasis to other regional LN groups. Patients who underwent total gastrectomy with D2 LN dissection from 2000 to 2010 were reviewed retrospectively. The clinicopathologic characteristics and long-term results of patients with splenic hilar LN metastasis were compared to those of patients with only metastasis to other extraperigastric LNs (stations #8a, #9, #11, or #12a). To investigate the survival benefit of performing splenic hilar LN dissection, the estimated therapeutic index for the procedure was calculated by multiplying the incidence of metastases in the hilar region by the survival rates for individuals with nodal involvement in that region. Of 602 patients, 87(14.5%) had hilar LN metastasis. The 5-year overall and relapse-free survival rates for patients with hilar LN metastasis were 24.1% and 12.1%, respectively. These rates were similar to those for patients with metastasis to other extraperigastric LNs ( P > 0.05), with similar recurrence patterns. Overall survival in the hilar LN metastasis group was better than that for patients with distant metastasis( P hilar LN dissection was 3.5, which was similar to index values for LN dissection at other extraperigastric LNs. Dissection of splenic hilar LNs during total gastrectomy for advanced gastric cancer allows for a prognosis similar to that achieved with dissection of extraperigastric LNs.

  9. Expansion of lymph node metastasis in mixed-type submucosal invasive gastric cancer.

    Science.gov (United States)

    Mikami, Koji; Hirano, Yukiko; Futami, Kitaro; Maekawa, Takafumi

    2017-07-18

    Mixed-type early gastric cancer (differentiated and undifferentiated components) incurs a higher risk of lymph node metastasis than pure-type early gastric cancer (only differentiated or only undifferentiated components). Therefore, we investigated the expansion of lymph node metastasis in mixed-type submucosal invasive gastric cancer in order to establish the most appropriate treatment for mixed-type cancer. We retrospectively analyzed 279 consecutive patients with submucosal invasive gastric cancer who underwent curative gastrectomy for gastric cancer between 1996 and 2015. We classified the patients into the mixed-type and pure-type groups according to histologic examination and evaluated the expansion of lymph node metastasis. The rate of lymph node metastasis was 23.7% (66/279) in the total patients, 36.4% (36/99) in the mixed-type group, and 16.6% (30/180) in the pure-type group. The significant independent risk factors for lymph node metastasis were tumor size ≥2.0 cm (P = 0.014), mixed-type gastric cancer (P mixed-type group. The rates of no. 7 lymph node metastasis in the total patients and mixed-type group were 2.9% (8/279) and 5.1% (5/99), respectively; the rates of no. 8a lymph node metastasis were 1.4% (4/279) and 4.0% (4/99), respectively. Mixed histological type is an independent risk factor for lymph node metastasis. Lymph node metastasis in mixed-type gastric cancer involves expansion to the no. 7 and no. 8a lymph nodes. Therefore, lymphadenectomy for mixed-type submucosal invasive gastric cancer requires D1+ or D2 dissection. Copyright © 2017. Published by Elsevier Taiwan.

  10. TEMPORAL TRENDS IN THE DETECTION RATES OF HEPATITIS B IN THE SANTA CATARINA STATE, BRAZIL

    Directory of Open Access Journals (Sweden)

    Chaiana Esmeraldino Mendes Marcon

    2014-04-01

    Full Text Available Hepatitis B is a serious public health problem. The state of Santa Catarina presents areas of high endemicity. The aim of this study was to describe temporal trends in detection rates of hepatitis B in the period from 2002 to 2009 in Santa Catarina and in its regions. A time series study was carried out. Crude rates were calculated and standardized by age using the direct method. Annual variation percentages were estimated by Joinpoint regression. There were two distinct and significant trends in Santa Catarina. From 2002 to 2006 a significant increase of 5.9% per year was observed. From 2006, there was a significant decrease of 6.4% per year. In this same period the southern and far-western regions had significant increases of 15.9% and 4.6% and significant decreases of 7.5% and 4.8%, respectively. Greater Florianópolis and Northeast also showed significant increases until 2006, of 15.4% and 17.4%, respectively. In the following period, non-significant decreases of 5.8% and 9.8% respectively were observed. Foz do Rio Itajaí and Planalto Serrano showed non-significant increases up to half of the studied period of 21.1% and 12.0%, respectively and after, significant decreases of 21.5% and 18.0%, respectively. Vale do Itajaí showed a significant decrease of 9.7%; Planalto Norte showed a non-significant decrease of 0.6% and Midwest a non-significant increase of 2.7% per year, in the period from 2002 to 2009.

  11. Noise-tolerant instantaneous heart rate and R-peak detection using short-term autocorrelation for wearable healthcare systems.

    Science.gov (United States)

    Fujii, Takahide; Nakano, Masanao; Yamashita, Ken; Konishi, Toshihiro; Izumi, Shintaro; Kawaguchi, Hiroshi; Yoshimoto, Masahiko

    2013-01-01

    This paper describes a robust method of Instantaneous Heart Rate (IHR) and R-peak detection from noisy electrocardiogram (ECG) signals. Generally, the IHR is calculated from the R-wave interval. Then, the R-waves are extracted from the ECG using a threshold. However, in wearable bio-signal monitoring systems, noise increases the incidence of misdetection and false detection of R-peaks. To prevent incorrect detection, we introduce a short-term autocorrelation (STAC) technique and a small-window autocorrelation (SWAC) technique, which leverages the similarity of QRS complex waveforms. Simulation results show that the proposed method improves the noise tolerance of R-peak detection.

  12. Oral gingival metastasis: A diagnostic dilemma

    Directory of Open Access Journals (Sweden)

    Nalini Aswath

    2017-01-01

    Full Text Available Oral cavity is a rare target for metastasis with an incidence of 1% among all oral cancers. In 24% of such cases, oral metastasis is the first indication of an undiagnosed primary. Metastatic oral malignancies have been reported in the mandible, tongue, and gingiva. Although gingival metastasis has been reported from lung, prostate, rectal carcinoma in men and carcinoma of breast, adrenal glands, and genitalia in females, gingival metastasis from carcinoma of the penis has not been reported. Herein, a case of metastatic gingival carcinoma that developed after extraction of teeth from primary carcinoma of the penis is presented. An extensive literature search revealed no such similar case reports.

  13. CT diagnosis of peritoneal metastasis tumor

    International Nuclear Information System (INIS)

    Deng Xueying; Chen Xiaoqi; Qi Le; Huang Feng

    2005-01-01

    Objective: To study the CT findings and diagnosis of peritoneal metastasis. Methods: The CT findings of 17 cases with surgical- pathologically proved peritoneal metastasis were analyzed retrospectively. Results The CT findings of peritoneal metastasis included: (1)ascites (12 cases ); (2)the aternation of parietal peritoneum including broad band thickening (7 cases), nodular sign (2 cases), and massive thickening (1 cases); (3) the involved omentum and mesenterium: 'smut' appearances (7 cases), nodular sign (2 cases), 'omental cake' (5 cases); (4) the invlovement of mesenteric vessels; (5) single-or multi-cystic lesions within peritoneum (1 case) . Conclusion: CT scan is the first choice for metastasis of peritoneum. (authors)

  14. Andrographolide Induces Autophagic Cell Death and Inhibits Invasion and Metastasis of Human Osteosarcoma Cells in An Autophagy-Dependent Manner

    Directory of Open Access Journals (Sweden)

    Ying Liu

    2017-11-01

    Full Text Available Background/Aims: Osteosarcoma (OS is the most common primary malignant tumor of bone tissue. Although treatment effectiveness has improved, the OS survival rate has fluctuated in recent years. Andrographolide (AG has been reported to have antitumor activity against a variety of tumors. Our aim was to investigate the effects and potential mechanisms of AG in human osteosarcoma. Methods: Cell viability and morphological changes were assessed by MTT and live/dead assays. Apoptosis was detected using Annexin V-FITC/PI double staining, DAPI, and caspase-3 assays. Autophagy was detected with mRFP-GFP-LC3 adenovirus transfection and western blot. Cell migration and invasion were detected by wound healing assay and Transwell® experiments. Results: AG dose-dependently reduced the viability of osteosarcoma cells. No increase in apoptosis was detected in AG-treated human OS MG-63 and U-2OS cells, and the pan-caspase inhibitor z-VAD did not attenuate AG-induced cell death. However, AG induced autophagy by suppressing PI3K/Akt/mTOR and enhancing JNK signaling pathways. 3-MA and Beclin-1 siRNA could reverse the cytotoxic effects of AG. In addition, AG inhibited the invasion and metastasis of OS, and this effect could be reversed with Beclin-1 siRNA. Conclusion: AG inhibits viability and induces autophagic death in OS cells. AG-induced autophagy inhibits the invasion and metastasis of OS.

  15. Detection rate of prostate cancer using prostate specific antigen in patients presenting with lower urinary tract symptoms: A retrospective study

    Directory of Open Access Journals (Sweden)

    Chavan P

    2009-01-01

    Full Text Available Background: Need for undertaking prostate biopsies for detection of prostate cancer is often decided on the basis of serum levels of prostate specific antigen (PSA. Aim: To evaluate the case detection rate of prostate cancer among patients presenting with lower urinary tract symptoms (LUTS on the basis of PSA levels and to assess the scope of prostate biopsy in these patients. Setting and Design: A retrospective study from a tertiary care center. Materials and Methods: The clinical and histopathological data of 922 patients presenting with LUTS in the last five years was obtained from the medical record section. They had been screened for prostate cancer using PSA and /or digital rectal examination examination followed by confirmation with prostate biopsy. Statistical Analysis Used: Detection rate and receiver operating characteristic curve were performed using SPSS 16 and Medcalc softwares. Results: The detection rate of prostate cancer according to the PSA levels was 0.6%, 2.3%, 2.5%, 34.1% and 54.9% in the PSA range of 0-4, 4-10, 10-20, 20-50 and> 50 ng/ml, respectively. Maximum prostate cancer cases were detected beyond a PSA value of 20 ng/ml whereas no significant difference in the detection rate was observed in the PSA range of 0-4, 4-10 and 10-20 ng/ml. Conclusion: A low detection rate of prostate cancer observed in the PSA range of 4-20 ng/ml in LUTS patients indicates the need for use of higher cutoff values of PSA in such cases. Therefore we recommend a cutoff of 20 ng/ml of PSA for evaluation of detection rate of prostate cancer among patients presenting with LUTS.

  16. The clinical significance of detection to heart rate deceleration capacity and heart rate variability in patients with chronic heart failure

    Directory of Open Access Journals (Sweden)

    Jiang-rong Zhou

    2015-01-01

    Full Text Available Objective: To study the change of heart rate deceleration capacity ( DC and heart rate variability in patients with chronic heart failure (CHF and its relationship with left ventricular ejection fraction (LVEF. Methods: DC, LVEF, time and frequency domain parameters of HRV were measured in 66 patients with CHF and 34 healthy adults (control group by using 24h Holter recordings and Echocardiography. The standard deviation of normal R-R intervals( SDNN, squares of differences between adjacent NN intervals ( RMSSD,low frequency power( LFn and high frequency power( HFn and the changes of LVEF were compared between  the two groups,the relationship between DC,LVEF and HRV were studied in patients with CHF. Results: The median value of DC in the patients with CHF was significantly lower than that in control group( 3.1 ± 2.4 ms vs 7.2 ± 1.3 ms,P <0.01.Incidence of abnormal DC in the CHF group was 57.5%,which was significantly higher than that in the control group (P <0.01.The HRV index, including SDNN、RMSSD、LFn、HFn, in the CHF group was significantly lower than that in normal control group (P < 0.01. Significant positive correlation between HRV index and LVEF were confirmed (P < 0.01. Conclusions: DC and HRV index are lower in patients with CHF and have a good correlation with the left ventricular ejection fraction.

  17. Using near infrared spectroscopy and heart rate variability to detect mental overload.

    Science.gov (United States)

    Durantin, G; Gagnon, J-F; Tremblay, S; Dehais, F

    2014-02-01

    Mental workload is a key factor influencing the occurrence of human error, especially during piloting and remotely operated vehicle (ROV) operations, where safety depends on the ability of pilots to act appropriately. In particular, excessively high or low mental workload can lead operators to neglect critical information. The objective of the present study is to investigate the potential of functional near infrared spectroscopy (fNIRS) - a non-invasive method of measuring prefrontal cortex activity - in combination with measurements of heart rate variability (HRV), to predict mental workload during a simulated piloting task, with particular regard to task engagement and disengagement. Twelve volunteers performed a computer-based piloting task in which they were asked to follow a dynamic target with their aircraft, a task designed to replicate key cognitive demands associated with real life ROV operating tasks. In order to cover a wide range of mental workload levels, task difficulty was manipulated in terms of processing load and difficulty of control - two critical sources of workload associated with piloting and remotely operating a vehicle. Results show that both fNIRS and HRV are sensitive to different levels of mental workload; notably, lower prefrontal activation as well as a lower LF/HF ratio at the highest level of difficulty, suggest that these measures are suitable for mental overload detection. Moreover, these latter measurements point toward the existence of a quadratic model of mental workload. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Carbon Dioxide Insufflation Increases Colonoscopic Adenoma Detection Rate Compared With Air Insufflation.

    Science.gov (United States)

    Mills, Christopher D; McCamley, Chere; Swan, Michael P

    2018-03-07

    To determine the effect of carbon dioxide insufflation on the most important outcome measure of colonoscopic quality: adenoma detection rate (ADR). Bowel cancer is the second most common cause of cancer deaths in males and females in Australia. Carbon dioxide has in recent times become the insufflation methodology of choice for screening colonoscopy for bowel cancer, as this has been shown to have significant advantages when compared with traditional air insufflation. Endoscopies performed over a period of 9 months immediately before and after the implementation of carbon dioxide insufflation at endoscopy centers were eligible for inclusion. The difference in ADR between the carbon dioxide and air insufflation methods was statistically significant, with an increased ADR in the carbon dioxide group. The superiority of carbon dioxide insufflation was sustained with a logistic regression model, which showed ADR was significantly impacted by insufflation method. Carbon dioxide insufflation is known to reduce abdominal pain, postprocedural duration of abdominal pain, abdominal distension, and analgesic requirements. This study represents for the first time the beneficial effect of carbon dioxide insufflation upon the key quality colonoscopy indicator of ADR.

  19. Auditory detection of an increment in the rate of a random process

    International Nuclear Information System (INIS)

    Brown, W.S.; Emmerich, D.S.

    1994-01-01

    Recent experiments have presented listeners with complex tonal stimuli consisting of components with values (i.e., intensities or frequencies) randomly sampled from probability distributions [e.g., R. A. Lutfi, J. Acoust. Soc. Am. 86, 934--944 (1989)]. In the present experiment, brief tones were presented at intervals corresponding to the intensity of a random process. Specifically, the intervals between tones were randomly selected from exponential probability functions. Listeners were asked to decide whether tones presented during a defined observation interval represented a ''noise'' process alone or the ''noise'' with a ''signal'' process added to it. The number of tones occurring in any observation interval is a Poisson variable; receiver operating characteristics (ROCs) arising from Poisson processes have been considered by Egan [Signal Detection Theory and ROC Analysis (Academic, New York, 1975)]. Several sets of noise and signal intensities and observation interval durations were selected which were expected to yield equivalent performance. Rating ROCs were generated based on subjects' responses in a single-interval, yes--no task. The performance levels achieved by listeners and the effects of intensity and duration are compared to those predicted for an ideal observer

  20. Dynamic detection-rate-based bit allocation with genuine interval concealment for binary biometric representation.

    Science.gov (United States)

    Lim, Meng-Hui; Teoh, Andrew Beng Jin; Toh, Kar-Ann

    2013-06-01

    Biometric discretization is a key component in biometric cryptographic key generation. It converts an extracted biometric feature vector into a binary string via typical steps such as segmentation of each feature element into a number of labeled intervals, mapping of each interval-captured feature element onto a binary space, and concatenation of the resulted binary output of all feature elements into a binary string. Currently, the detection rate optimized bit allocation (DROBA) scheme is one of the most effective biometric discretization schemes in terms of its capability to assign binary bits dynamically to user-specific features with respect to their discriminability. However, we learn that DROBA suffers from potential discriminative feature misdetection and underdiscretization in its bit allocation process. This paper highlights such drawbacks and improves upon DROBA based on a novel two-stage algorithm: 1) a dynamic search method to efficiently recapture such misdetected features and to optimize the bit allocation of underdiscretized features and 2) a genuine interval concealment technique to alleviate crucial information leakage resulted from the dynamic search. Improvements in classification accuracy on two popular face data sets vindicate the feasibility of our approach compared with DROBA.

  1. Intracerebral metastasis showing restricted diffusion: Correlation with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Duygulu, G. [Radiology Department, Ege University Medicine School, Izmir (Turkey); Ovali, G. Yilmaz [Radiology Department, Celal Bayar University Medicine School, Manisa (Turkey)], E-mail: gulgun.yilmaz@bayar.edu.tr; Calli, C.; Kitis, O.; Yuenten, N. [Radiology Department, Ege University Medicine School, Izmir (Turkey); Akalin, T. [Pathology Department, Ege University Medicine School, Izmir (Turkey); Islekel, S. [Neurosurgery Department, Ege University Medicine School, Izmir (Turkey)

    2010-04-15

    Objective: We aimed to detect the frequency of restricted diffusion in intracerebral metastases and to find whether there is correlation between the primary tumor pathology and diffusion-weighted MR imaging (DWI) findings of these metastases. Material and methods: 87 patients with intracerebral metastases were examined with routine MR imaging and DWI. 11 hemorrhagic metastatic lesions were excluded. The routine MR imaging included three plans before and after contrast enhancement. The DWI was performed with spin-echo EPI sequence with three b values (0, 500 and 1000), and ADC maps were calculated. 76 patients with metastases were grouped according to primary tumor histology and the ratios of restricted diffusion were calculated according to these groups. ADCmin values were measured within the solid components of the tumors and the ratio of metastases with restricted diffusion to that which do not show restricted diffusion were calculated. Fisher's exact and Mann-Whitney U tests were used for the statistical analysis. Results: Restricted diffusion was observed in a total of 15 metastatic lesions (19, 7%). Primary malignancy was lung carcinoma in 10 of these cases (66, 6%) (5 small cell carcinoma, 5 non-small cell carcinoma), and breast carcinoma in three cases (20%). Colon carcinoma and testicular teratocarcinoma were the other two primary tumors in which restricted diffusion in metastasis was detected. There was no statistical significant difference between the primary pathology groups which showed restricted diffusion (p > 0.05). ADCmin values of solid components of the metastasis with restricted diffusion and other metastasis without restricted diffusion also showed no significant statistical difference (0.72 {+-} 0.16 x 10{sup -3} mm{sup 2}/s and 0.78 {+-} 21 x 10{sup -3} mm{sup 2}/s respectively) (p = 0.325). Conclusion: Detection of restricted diffusion on DWI in intracerebral metastasis is not rare, particularly if the primary tumor is lung or breast

  2. Reduced metastasis of transgenic mammary cancer in urokinase-deficient mice

    DEFF Research Database (Denmark)

    Almholt, Kasper; Lund, L.R.; Rygaard, Jørgen

    2005-01-01

    A prominent phenotype of plasmin deficiency in mice is reduced metastasis in the MMTV-PymT transgenic breast cancer model. Proteolytically active plasmin is generated from inactive plasminogen by one of 2 activators, uPA or tPA. We now find that uPA deficiency alone significantly reduces metastasis...... >7-fold in the MMTV-PymT model. We studied a cohort of 55 MMTV-PymT transgenic mice, either uPA-deficient or wild-type controls. Tumor incidence, latency, growth rate and final primary tumor burden were not significantly affected by uPA deficiency. In contrast, average lung metastasis volume...

  3. Selectins mediate small cell lung cancer systemic metastasis.

    Directory of Open Access Journals (Sweden)

    Franziska Heidemann

    Full Text Available Metastasis formation is the major reason for the extremely poor prognosis in small cell lung cancer (SCLC patients. The molecular interaction partners regulating metastasis formation in SCLC are largely unidentified, however, from other tumor entities it is known that tumor cells use the adhesion molecules of the leukocyte adhesion cascade to attach to the endothelium at the site of the future metastasis. Using the human OH-1 SCLC line as a model, we found that these cells expressed E- and P-selectin binding sites, which could be in part attributed to the selectin binding carbohydrate motif sialyl Lewis A. In addition, protein backbones known to carry these glycotopes in other cell lines including PSGL-1, CD44 and CEA could be detected in in vitro and in vivo grown OH1 SCLC cells. By intravital microscopy of murine mesenterial vasculature we could capture SCLC cells while rolling along vessel walls demonstrating that SCLC cells mimic leukocyte rolling behavior in terms of selectin and selectin ligand interaction in vivo indicating that this mechanism might indeed be important for SCLC cells to seed distant metastases. Accordingly, formation of spontaneous distant metastases was reduced by 50% when OH-1 cells were xenografted into E-/P-selectin-deficient mice compared with wild type mice (p = 0.0181. However, as metastasis formation was not completely abrogated in selectin deficient mice, we concluded that this adhesion cascade is redundant and that other molecules of this cascade mediate metastasis formation as well. Using several of these adhesion molecules as interaction partners presumably make SCLC cells so highly metastatic.

  4. Pulmonary metastasis in thyroid cancer

    International Nuclear Information System (INIS)

    Samuel, A.M.; Rajashekharrao, B.; Shah, D.H.

    1999-01-01

    Although thyroid cancer (TC) in its differentiated form is generally associated with a good prognosis and a near normal life expectancy, a subset of patients especially with distant metastatic disease may run an aggressive course leading to poor survival and early death. The clinical presentation and the manner in which the disease progresses differs with the site and type of the metastatic disease. The behaviour and course of skeletal metastasis has been described elsewhere. The biological behaviour and treatment of pulmonary metastatic disease is focussed on

  5. Pancreatic Metastasis from Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Julian Jacob

    2010-01-01

    Full Text Available The pancreas is an unusual location for metastases from other primary cancers. Rarely, pancreatic metastases from kidney or colorectal cancers have been reported. However, a variety of other cancers may also spread to the pancreas. We report an exceptional case of pancreatic metastasis from prostate cancer. Differences in management between primary and secondary pancreatic tumors make recognition of metastases to the pancreas an objective of first importance. Knowledge of unusual locations for metastatic spread will reduce diagnostic delay and lead to a timely delivery of an appropriate treatment.

  6. Dissecting and Targeting Latent Metastasis

    Science.gov (United States)

    2014-09-01

    Option in Brain Metastasis Manuel Valiente,1 Anna C. Obenauf,1 Xin Jin,1 Qing Chen,1 Xiang H.-F. Zhang,1,8 Derek J. Lee,1 Jamie E. Chaft,2 Mark G. Kris,2...of poor response to tamoxifen therapy in recurrent breast cancer. J. Natl. Cancer Inst. 87, 751–756. Francia, G., Cruz -Munoz, W., Man, S., Xu, P... Manuel Valiente1, Xin Jin1†, Ekrem Emrah Er1, Ruzeen Patwa1, Ke Xu3 and Joan Massagué1 1 Cancer Biology and Genetics Program, 2 Department of

  7. Endocannabinoids as Guardians of Metastasis

    Directory of Open Access Journals (Sweden)

    Irmgard Tegeder

    2016-02-01

    Full Text Available Endocannabinoids including anandamide and 2-arachidonoylglycerol are involved in cancer pathophysiology in several ways, including tumor growth and progression, peritumoral inflammation, nausea and cancer pain. Recently we showed that the endocannabinoid profiles are deranged during cancer to an extent that this manifests in alterations of plasma endocannabinoids in cancer patients, which was mimicked by similar changes in rodent models of local and metastatic cancer. The present topical review summarizes the complexity of endocannabinoid signaling in the context of tumor growth and metastasis.

  8. Relationship of detection rate of PET cancer screening examinees and risk factors. Analysis of background of examinees

    International Nuclear Information System (INIS)

    Shibata, Koji; Uno, Kimiichi; Arai, Masami; Matsuura, Masaaki; Yoshida, Teruhiko; Momose, Toshimitsu; Ohtomo, Kuni

    2011-01-01

    Positron emission tomography (PET) cancer screening is performed widely in Japan as opportunistic screening, but no study has focused on the correlation with various cancer risk factors and the seeking bias of examinees and cancer detection rate. Analyzing our large series of PET cancer screening data, correlations with cancer detection rates according to general cancer risk factors and PET detection survey were reviewed, and the selection bias of the medical examinees was determined. 19189 examinees who underwent PET cancer screening were enrolled. Using logistic-regression analysis, we analyzed correlations between smoking history/drinking history/cancer family history and detection rates of thyroid cancer/breast cancer/colorectal cancer/lung cancer, which are the main malignancies detected in PET cancer screening. In addition, we evaluated seeking bias of examinees, analyzing correlations between the presence of cancer risk factors and prior screening checkups at other institutions to our PET cancer screening using a matched case-control study. Cancer detection rates by FDG-PET were 1.17% (224/19189), being much higher than those of standard cancer mass screenings. In males, statistically significant correlations were seen between lung cancer and smoking, and between prostate cancer and a family history of prostate cancer, but not between the detection rates of three other types of cancer (thyroid cancer/lung cancer/colorectal cancer) and other cancer risk factors. In females, detection rates of four types of cancer (thyroid cancer/lung cancer/colorectal cancer/breast cancer) were significantly higher in the examinees without cancer risks, and subgroup analysis according to types of cancer did not indicate significant correlations either. The matched case-control study evaluating seeking bias indicated that a significant proportion of the examinees with cancer risks had undergone prior cancer screening at other institutions. Our study indicated that there was

  9. Metastasis

    Science.gov (United States)

    ... and Care Surgical Treatment Laparoscopic Surgery Vaccine Radiation Therapy Chemotherapy Clinical Trials Pain Management Nutrition and Exercise Holistic Care Pathology Intraductal Papillary Mucinous Neoplasms Islet Cell ...

  10. Short-term outcomes and safety of computed tomography-guided percutaneous microwave ablation of solitary adrenal metastasis from lung cancer: A multi-center retrospective study

    Energy Technology Data Exchange (ETDEWEB)

    Men, Min; Ye, Xin; Yang, Xia; Zheng, Aimin; Huang, Guang Hui; Wei, Zhigang [Dept. of Oncology, Shandong Provincial Hospital Affiliated with Shandong University, Jinan (China); Fan, Wei Jun [Imaging and Interventional Center, Sun Yat-sen University Cancer Center, Guangzhou (China); Zhang, Kaixian [Dept. of Oncology, Teng Zhou Central People' s Hospital Affiliated with Jining Medical College, Tengzhou (China); Bi, Jing Wang [Dept. of Oncology, Jinan Military General Hospital of Chinese People' s Liberation Army, Jinan (China)

    2016-11-15

    To retrospectively evaluate the short-term outcomes and safety of computed tomography (CT)-guided percutaneous microwave ablation (MWA) of solitary adrenal metastasis from lung cancer. From May 2010 to April 2014, 31 patients with unilateral adrenal metastasis from lung cancer who were treated with CT-guided percutaneous MWA were enrolled. This study was conducted with approval from local Institutional Review Board. Clinical outcomes and complications of MWA were assessed. Their tumors ranged from 1.5 to 5.4 cm in diameter. After a median follow-up period of 11.1 months, primary efficacy rate was 90.3% (28/31). Local tumor progression was detected in 7 (22.6%) of 31 cases. Their median overall survival time was 12 months. The 1-year overall survival rate was 44.3%. Median local tumor progression-free survival time was 9 months. Local tumor progression-free survival rate was 77.4%. Of 36 MWA sessions, two (5.6%) had major complications (hypertensive crisis). CT-guided percutaneous MWA may be fairly safe and effective for treating solitary adrenal metastasis from lung cancer.

  11. Angiotensin II facilitates breast cancer cell migration and metastasis.

    Directory of Open Access Journals (Sweden)

    Sylvie Rodrigues-Ferreira

    Full Text Available Breast cancer metastasis is a leading cause of death by malignancy in women worldwide. Efforts are being made to further characterize the rate-limiting steps of cancer metastasis, i.e. extravasation of circulating tumor cells and colonization of secondary organs. In this study, we investigated whether angiotensin II, a major vasoactive peptide both produced locally and released in the bloodstream, may trigger activating signals that contribute to cancer cell extravasation and metastasis. We used an experimental in vivo model of cancer metastasis in which bioluminescent breast tumor cells (D3H2LN were injected intra-cardiacally into nude mice in order to recapitulate the late and essential steps of metastatic dissemination. Real-time intravital imaging studies revealed that angiotensin II accelerates the formation of metastatic foci at secondary sites. Pre-treatment of cancer cells with the peptide increases the number of mice with metastases, as well as the number and size of metastases per mouse. In vitro, angiotensin II contributes to each sequential step of cancer metastasis by promoting cancer cell adhesion to endothelial cells, trans-endothelial migration and tumor cell migration across extracellular matrix. At the molecular level, a total of 102 genes differentially expressed following angiotensin II pre-treatment were identified by comparative DNA microarray. Angiotensin II regulates two groups of connected genes related to its precursor angiotensinogen. Among those, up-regulated MMP2/MMP9 and ICAM1 stand at the crossroad of a network of genes involved in cell adhesion, migration and invasion. Our data suggest that targeting angiotensin II production or action may represent a valuable therapeutic option to prevent metastatic progression of invasive breast tumors.

  12. Remote vital parameter monitoring in neonatology - robust, unobtrusive heart rate detection in a realistic clinical scenario.

    Science.gov (United States)

    Blanik, Nikolai; Heimann, Konrad; Pereira, Carina; Paul, Michael; Blazek, Vladimir; Venema, Boudewijn; Orlikowsky, Thorsten; Leonhardt, Steffen

    2016-12-01

    Vital parameter monitoring of term and preterm infants during incubator care with self-adhesive electrodes or sensors directly positioned on the skin [e.g. photoplethysmography (PPG) for oxygen saturation or electrocardiography (ECG)] is an essential part of daily routine care in neonatal intensive care units. For various reasons, this kind of monitoring contains a lot of stress for the infants. Therefore, there is a need to measure vital parameters (for instance respiration, temperature, pulse, oxygen saturation) without mechanical or conductive contact. As a non-contact method of monitoring, we present an adapted version of camera-based photoplethysmography imaging (PPGI) according to neonatal requirements. Similar to classic PPG, the PPGI camera detects small temporal changes in the term and preterm infant's skin brightness due to the cardiovascular rhythm of dermal blood perfusion. We involved 10 preterm infants in a feasibility study [five males and five females; mean gestational age: 26 weeks (24-28 weeks); mean biological age: 35 days (8-41 days); mean weight at the time of investigation: 960 g (670-1290 g)]. The PPGI camera was placed directly above the incubators with the infant inside illuminated by an infrared light emitting diode (LED) array (850 nm). From each preterm infant, 5-min video sequences were recorded and analyzed post hoc. As the measurement scenario was kept as realistic as possible, the infants were not constrained in their movements in front of the camera. Movement intensities were assigned into five classes (1: no visible motion to 5: heavy struggling). PPGI was found to be significantly sensitive to movement artifacts. However, for movement classes 1-4, changes in blood perfusion according to the heart rate (HR) were recovered successfully (Pearson correlation: r=0.9759; r=0.765 if class 5 is included). The study was approved by the Ethics Committee of the Universal Hospital of the RWTH Aachen University, Aachen, Germany (EK 254/13).

  13. Humeral Metastasis from Cervical Cancer: A Rare Case Report

    OpenAIRE

    Sonia Chhabra; KanikaTaneja; Megha Ralli; Sunita Singh; Aditi Arora; Sohrab Arora; Pansi Gupta

    2015-01-01

    Long bone metastasis in cervical cancer is a rare presentation generally seen in the lumbar column or ribs. The reported rates of bone metastases are between 15%-29%. It is associated with poor prognosis. Bone scan and magnetic resonance imaging are useful techniques for diagnosis. In this case report, a 32-year old female with a previous history of cervical carcinoma FIGO stage IIIA presented with severe pain and swelling in her right humerus. X-ray and magnetic resonance imag...

  14. [Evaluation of heart impact in the 100 m extreme intensity sport using near-infrared non-invasive muscle oxygen detecting device and sports heart rate detection technology].

    Science.gov (United States)

    Wang, Pei-Yong; Long, Fei-Xiao; Fu, Lan-Ying; Li, Yue; Ding, Hai-Shu; Qu, An-Lian; Zhou, Xiao-Ping

    2010-02-01

    Using continuous two wavelength near-infrared technology to detect the variation in the consistency of oxygen hemoglobin in the muscle and the sports heart rate wireless real time collection technology, we devised the real time muscle tissue oxygenation and instantaneous heart rate experiment scheme and implemented it for the process of the 100 m run with two parameters given simultaneously. The experiment shows that the concentration of the oxygen hemoglobin in the muscle tissue continues decreasing after the end of the 100 m run, and the time interval between the moment when the concentration of the oxygen hemoglobin attains the minimum value and the moment when the athletes finish the 100 m run is (6.65 +/- 1.10) sec; while the heart rate continues increasing after the end of the 100 m run, and the time interval between the moment when the heart rate attains the maximum value and the moment when the athletes finish the 100 m run is (8.00 +/- 1.57) sec. The results show that the two wavelength near-infrared tissue oxygenation detection technology and the sports heart rate real time collection equipment can accurately measure the sports tissue oxygenation and the heart rate in the extreme intensity sport, and reveal the process of muscle oxygen transportation and consumption and its dynamic character with the heart rate in the extreme intensity sport.

  15. Intramedullary spinal cord metastasis from colonic carcinoma presenting as Brown-Sequard syndrome: a case report

    LENUS (Irish Health Repository)

    Kaballo, Mohammed A

    2011-08-02

    Abstract Introduction Intramedullary spinal cord metastasis is very rare. The majority are discovered incidentally during autopsy. Most symptomatic patients present with rapidly progressive neurological deficits and require immediate examination. Few patients demonstrate features of Brown-Séquard syndrome. Radiotherapy is the gold-standard of therapy for Intramedullary spinal cord metastasis. The overall prognosis is poor and the mortality rate is very high. We present what is, to the best of our knowledge, the first case of Intramedullary spinal cord metastasis of colorectal carcinoma presenting as Brown-Séquard syndrome. Case presentation We present the case of a 71-year-old Caucasian man with colonic adenocarcinoma who developed Intramedullary spinal cord metastasis and showed features of Brown-Séquard syndrome, which is an uncommon presentation of Intramedullary spinal cord metastasis. Conclusion This patient had an Intramedullary spinal cord metastasis, a rare form of metastatic disease, secondary to colonic carcinoma. The metastasis manifested clinically as Brown-Séquard syndrome, itself a very uncommon condition. This syndrome is rarely caused by intramedullary tumors. This unique case has particular interest in medicine, especially for the specialties of medical, surgical and radiation oncology. We hope that it will add more information to the literature about these entities.

  16. A rare case of thyroid metastasis from pancreatic adenocarcinoma.

    LENUS (Irish Health Repository)

    Kelly, Michael E

    2012-02-01

    CONTEXT: Thyroid metastasis from pancreatic adenocarcinoma is extremely rare, with only two previous cases in the literature. We report a case of pancreatic adenocarcinoma metastasising to the thyroid. We review the incidence, diagnosis, and management of this rare occurrence. CASE REPORT: A 38-year-old man with a synchronous 6-month history of thyroid swelling, presented with epigastric pain and signs of obstructive jaundice. He was investigated by abdominal computerised tomography and endoscopic retrograde cholangiopancreatography. The diagnosis of pancreatic neoplasm was made. His thyroid neoplasm was investigated at another tertiary centre and thought to be a papillary neoplasm. He underwent a pancreaticoduodenectomy and recovered well post-operatively. Eight weeks later he had a total thyroidectomy. Histology confirmed that the thyroid mass was both morphologically and immunophenotypically similar to the pancreatic neoplasm. CONCLUSION: This case demonstrates the importance of a full investigation when a patient with suspected neoplastic history presents with a thyroid nodule. We outline the crucial role that immunohistochemistry plays in detecting and classifying primary and secondary thyroid neoplasms. The detection of a solitary thyroid metastasis from pancreatic adenocarcinoma may indicate a poor prognosis, and it is debatable whether resection of the primary should be undertaken when it presents with a solitary metastasis.

  17. Tumour metastasis-associated gene profiling using one-dimensional microfluidic beads array

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Great efforts have been made on the early diagnosis and molecular mechanism research of tumour metastasis in recent years. In this paper, based on the one-dimensional microfluidic beads array, a novel platform for tumour metastasis-associated genes profiling has been developed by depositing nucleic acids functional beads in the microchannel. This platform is sensitive (limit of detection: 0.02 nmol/L) and can perform mRNAs analysis without PCR. Two human colon cancer cell lines (primary and metastatic) from the same patient were used as a model, and transcriptional expression profiling of multiple tumour metastasis-associated genes in these two cell lines was successfully achieved. Furthermore, the results obtained on the beads array were validated by RT-PCR. This novel beads array has advantages of high sensitivity, little sample consumption, short assay time, low cost and high throughput capability. It holds the potential in early diagnosis and mechanism research of tumour metastasis.

  18. Contiguous spinal metastasis mimicking infectious spondylodiscitis

    International Nuclear Information System (INIS)

    Lee, Chul Min; Lee, Seung Hun; Bae, Ji Yoon

    2015-01-01

    Differential diagnosis between spinal metastasis and infectious spondylodiscitis is one of the occasional challenges in daily clinical practice. We encountered an unusual case of spinal metastasis in a 75-year-old female breast cancer patient that mimicked infectious spondylodiscitis. Magnetic resonance imaging (MRI) showed diffuse bone marrow infiltrations with paraspinal soft tissue infiltrative changes in 5 contiguous cervical vertebrae without significant compression fracture or cortical destruction. These MRI findings made it difficult to differentiate between spinal metastasis and infectious spondylodiscitis. Infectious spondylodiscitis such as tuberculous spondylodiscitis was regarded as the more appropriate diagnosis due to the continuous involvement of > 5 cervical vertebrae. The patient's clinical presentation also supported the presumptive diagnosis of infectious spondylodiscitis rather than spinal metastasis. Intravenous antibiotics were administered, but clinical symptoms worsened despite treatment. After pathologic confirmation by computed tomography-guided biopsy, we were able to confirm a final diagnosis of spinal metastasis

  19. Contiguous spinal metastasis mimicking infectious spondylodiscitis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Chul Min; Lee, Seung Hun [Dept. of Radiology, Hanyang University Hospital, Seoul (Korea, Republic of); Bae, Ji Yoon [Dept. of Pathology, National Police Hospital, Seoul (Korea, Republic of)

    2015-12-15

    Differential diagnosis between spinal metastasis and infectious spondylodiscitis is one of the occasional challenges in daily clinical practice. We encountered an unusual case of spinal metastasis in a 75-year-old female breast cancer patient that mimicked infectious spondylodiscitis. Magnetic resonance imaging (MRI) showed diffuse bone marrow infiltrations with paraspinal soft tissue infiltrative changes in 5 contiguous cervical vertebrae without significant compression fracture or cortical destruction. These MRI findings made it difficult to differentiate between spinal metastasis and infectious spondylodiscitis. Infectious spondylodiscitis such as tuberculous spondylodiscitis was regarded as the more appropriate diagnosis due to the continuous involvement of > 5 cervical vertebrae. The patient's clinical presentation also supported the presumptive diagnosis of infectious spondylodiscitis rather than spinal metastasis. Intravenous antibiotics were administered, but clinical symptoms worsened despite treatment. After pathologic confirmation by computed tomography-guided biopsy, we were able to confirm a final diagnosis of spinal metastasis.

  20. Use of Selective Fungal Culture Media Increases Rates of Detection of Fungi in the Respiratory Tract of Cystic Fibrosis Patients.

    Science.gov (United States)

    Hong, Gina; Miller, Heather B; Allgood, Sarah; Lee, Richard; Lechtzin, Noah; Zhang, Sean X

    2017-04-01

    The prevalence of fungi in the respiratory tracts of cystic fibrosis (CF) patients has risen. However, fungal surveillance is not routinely performed in most clinical centers in the United States, which may lead to an underestimation of the true prevalence of the problem. We conducted a prospective study comparing the rates of detection for clinically important fungi (CIF), defined as Aspergillus , Scedosporium , and Trichosporon species and Exophiala dermatitidis , in CF sputa using standard bacterial and selective fungal culture media, including Sabouraud dextrose agar with gentamicin (SDA), inhibitory mold agar (IMA), and brain heart infusion (BHI) agar with chloramphenicol and gentamicin. We described the prevalence of these fungi in an adult CF population. A total of 487 CF respiratory samples were collected from 211 unique participants. CIF were detected in 184 (37.8%) samples. Only 26.1% of CIF-positive samples were detected in bacterial culture medium, whereas greater rates of detection for fungi were found in IMA (65.8%; P culture media and longer incubation periods yielded higher rates of detection for CIF in CF sputum samples compared with that detected in bacterial culture medium, resulting in an underdetection of fungi by bacterial culture alone. The prevalence of fungi in CF may be better estimated by using selective fungal culture media, and this may translate to important clinical decisions. Copyright © 2017 American Society for Microbiology.

  1. Annexin A7 suppresses lymph node metastasis of hepatocarcinoma cells in a mouse model

    International Nuclear Information System (INIS)

    Jin, Yanling; Wang, Shaoqing; Chen, Wenjing; Zhang, Jun; Wang, Bo; Guan, Hongwei; Tang, Jianwu

    2013-01-01

    Hepatocellular carcinoma (HCC) is one of the leading causes of cancer death in China. This study investigated the effects of Annexin A7 (ANXA7) on the inhibition of HCC lymph node metastasis in a mouse model. The stable knockup and knockdown of Annexin A7-expressing HCC cells using Annexin A7 cDNA and shRNA vectors, respectively, were injected into a mouse footpad to establish primary and metastatic tumors in mice. On the 14th, 21st, and 28th days after HCC cells inoculation, the mice were sacrificed for inspection of primary and secondary tumors and immunohistochemistry of Annexin A7 expression. The lymph node metastasis rate of the F ANXA7-control group was 77%, and the lymph node metastasis rate of the F ANXA7-down group was 100% (p < 0.05). In contrast, the lymph node metastasis rate of the P ANXA7-up group was 0% and that of the P ANXA7-control group was 36% (p < 0.05). Furthermore, immunohistochemistry experiments revealed that the subcellular localization of Annexin A7 protein in both primary and lymph node-metastasized tumors was mainly in the cytosol. In addition, the expression of the 47 kDa and 51 kDa isoforms of Annexin A7 protein changed during tumor progression. This study indicated that Annexin A7 expression was able to inhibit HCC lymph node metastasis, whereas knockdown of Annexin A7 expression significantly induced HCC metastasis to local lymph nodes

  2. Osteopontin-enhanced hepatic metastasis of colorectal cancer cells.

    Directory of Open Access Journals (Sweden)

    Jianjin Huang

    Full Text Available Liver metastasis is a major cause of mortality from colorectal cancer (CRC. However, mechanisms underlying this process are largely unknown. Osteopontin (OPN is a secreted phosphorylated glycoprotein that is involved in tumor migration and metastasis. The role of OPN in cancer is currently unclear. In this study, OPN mRNA was examined in tissues from CRC, adjacent normal mucosa, and liver metastatic lesions using quantitative real-time PCR analysis. The protein expression of OPN and its receptors (integrin αv and CD44 v6 was detected by using an immunohistochemical (IHC method. The role of OPN in liver metastasis was studied in established colon cancer Colo-205 and SW-480 cell lines transfected with sense- or antisense-OPN eukaryotic expression plasmids by flow cytometry and cell adhesion assay. Fluorescence redistribution after photobleaching (FRAP was used to study gap functional intercellular communication (GJIC among OPN-transfected cells. It was found that OPN was highly expressed in metastatic hepatic lesions from CRC compared to primary CRC tissue and adjacent normal mucosa. The expression of OPN mRNA in tumor tissues was significantly related with the CRC stages. OPN expression was also detected in normal hepatocytes surrounding CRC metastatic lesions. Two known receptors of OPN, integrin αv and CD44v6 proteins, were strongly expressed in hepatocytes from normal liver. CRC cells with forced OPN expression exhibited increased heterotypic adhesion with endothelial cells and weakened intercellular communication. OPN plays a significant role in CRC metastasis to liver through interaction with its receptors in hepatocytes, decreased homotypic adhesion, and enhanced heterotypic adhesion.

  3. Establishment of A Novel Chinese Human Lung Adenocarcinoma Cell Line CPA-Yang3 and Its Real Bone Metastasis Clone CPA-Yang3BM in Immunodeficient Mice

    Directory of Open Access Journals (Sweden)

    Shunfang YANG

    2011-02-01

    Full Text Available Background and objective The recurrence and metastasis of lung cancer is a tough problem worldwide. The aim of this study is to establish a novel Chinese lung adenocarcinoma cell line and its real bone-seeking clone sub-line for exploring the molecular mechanism of lung cancer metastasis. Methods The cells came from the pleural effusion of a sixtyfive years old female patient with lung adenocarcinoma and supraclavicular lymph node metastases. The gene expression was detected by real-time quantitative PCR. Intracardiac injection of the cells into nude mice was performed and in vivo imaging was obtained by bone scintigraphy and conventional radiography. Bone metastases were determined on bone scintigraphy and then the lesions were resected under deep anesthesia for bone metastasis cancer cell culture. The process was repeated for four cycles to obtain a real bone-seeking clone. Results The tumorigenesis rate started at 4th passage in immunodeficient mice via subcutaneously and as well as later passages. Approximately 1×106 cancer cells were injected into left cardiac ventricle of immunodeficient mice resulted bone metastasis sites were successfully revealed by bone scintigraphy and pathological diagnosis, the mandible (100%, scapula (33%, humerus (50%, vertebral column (50%, femur (66.7% and accompanied invasion with other organs, the adrenal gland (17%, pulmonary (33%, liver (50%, submaxillary gland (33% in the mice after inoculation two-three weeks. The chromosome karyotype analysis of the cells was subdiploid. Quantitative real-time PCR was used to examined and compared with SPC-A-1 lung adenocarcinoma, ESM1, VEGF-C, IL-6, IL-8, AR, SVIL, FN1 genes were overexpress. The novel cell was named CPA-Yang3. The femur metastasis cell was repeated in vivo-in vitro-in vivo with three cycles and harvested a real bone metastasis clone. It was named CPA-Yang3BM. Conclusion Tne characteristics of novel strain CPAYang3 is a highly metastasis cell line of

  4. Incorporating an Exercise Detection, Grading, and Hormone Dosing Algorithm Into the Artificial Pancreas Using Accelerometry and Heart Rate

    OpenAIRE

    Jacobs, Peter G.; Resalat, Navid; El Youssef, Joseph; Reddy, Ravi; Branigan, Deborah; Preiser, Nicholas; Condon, John; Castle, Jessica

    2015-01-01

    In this article, we present several important contributions necessary for enabling an artificial endocrine pancreas (AP) system to better respond to exercise events. First, we show how exercise can be automatically detected using body-worn accelerometer and heart rate sensors. During a 22 hour overnight inpatient study, 13 subjects with type 1 diabetes wearing a Zephyr accelerometer and heart rate monitor underwent 45 minutes of mild aerobic treadmill exercise while controlling their glucose ...

  5. Drug Development for Metastasis Prevention.

    Science.gov (United States)

    Fontebasso, Yari; Dubinett, Steven M

    2015-01-01

    Metastatic disease is responsible for 90% of death from solid tumors. However, only a minority of metastasis-specific targets has been exploited therapeutically, and effective prevention and suppression of metastatic disease is still an elusive goal. In this review, we will first summarize the current state of knowledge about the molecular features of the disease, with particular focus on steps and targets potentially amenable to therapeutic intervention. We will then discuss the reasons underlying the paucity of metastatic drugs in the current oncological arsenal and potential ways to overcome this therapeutic gap. We reason that the discovery of novel promising targets, an increased understanding of the molecular features of the disease, the effect of disruptive technologies, and a shift in the current preclinical and clinical settings have the potential to create more successful drug development endeavors.

  6. Stereotactic radiotherapy for brain metastasis

    International Nuclear Information System (INIS)

    Noel, G.; Daisne, J.F.; Thillays, F.

    2012-01-01

    Stereotactic radiosurgery is now well implanted in the radiotherapy treatment tools of brain metastasis. The dose can be delivered in one or multiple sessions. Results seem equivalent. CT scan and MRI imaging are required to delineate and calculate dosimetry. Doses are variable according to the size of the metastases, localization, pathology or equipment. Stabilization or reduction of tumour size is the rules after stereotactic treatment. Impact in terms of overall survival is more difficult to apprehend because of the general context of the disease. Many questions remain unresolved, such as the usefulness of whole brain irradiation, adaptation of the treatment schedule to tumour pathophysiology, role of stereotactic treatment after surgery of metastases, etc. (authors)

  7. Crural subcutaneous metastasis of a breast cancer. Arteriographic and scintigraphic evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Wenger, J J; Moyses, B; Methlin, G; Tongio, J [Centre Hospitalier Universitaire, 67 - Strasbourg (France); Centre Paul-Strauss, 67 - Strasbourg (France). Service des Radio-Isotopes)

    1977-03-01

    One case of a crural subcutaneous metastasis of a mammary cancer detected by total body scintigraphy using the sup(99m)Tc-pyrophosphate and arteriography is reported. They emphasize the value of scintigraphy in the detection of extra-osseous metastases of breast cancer.

  8. Sleep Apnoea Detection in Single Channel ECGs by Analyzing Heart Rate Dynamics

    National Research Council Canada - National Science Library

    Zywietz, C

    2001-01-01

    .... Sleep disorders are typically investigated by means of polysomnographic recordings. We have analyzed 70 eight-hour single-channel ECG recordings to find out to which extent sleep apneas may be detected from the ECG alone...

  9. Forecasting the new case detection rate of leprosy in four states of Brazil: A comparison of modelling approaches

    NARCIS (Netherlands)

    D.J. Blok (David); R.E. Crump (Ron E.); Sundaresh, R. (Ram); M. Ndeffo-Mbah (Martial); Galvani, A.P. (Alison P.); T.C. Porco (Travis C.); S.J. de Vlas (Sake); G.F. Medley (Graham F.); J.H. Richardus (Jan Hendrik)

    2017-01-01

    textabstractBackground Brazil has the second highest annual number of new leprosy cases. The aim of this study is to formally compare predictions of future new case detection rate (NCDR) trends and the annual probability of NCDR falling below 10/100,000 of four different modelling approaches in four

  10. High-Frame-Rate Power Doppler Ultrasound Is More Sensitive than Conventional Power Doppler in Detecting Rheumatic Vascularisation

    NARCIS (Netherlands)

    M. van der Ven (Myrthe); J.J. Luime (Jolanda); van der Velden, L.L. (Levinia L.); J.G. Bosch (Hans); J.M.W. Hazes (Mieke); H.J. Vos (Rik)

    2016-01-01

    textabstractEarly recognition of joint inflammation will increase treatment efficacy in rheumatoid arthritis (RA). Yet, conventional power Doppler (PD) ultrasound might not be sufficiently sensitive to detect minor inflammation. We investigated the sensitivity of high-frame rate Doppler, combined

  11. Transfer Rate Edited experiment for the selective detection of Chemical Exchange via Saturation Transfer (TRE-CEST)

    Science.gov (United States)

    Friedman, Joshua I.; Xia, Ding; Regatte, Ravinder R.; Jerschow, Alexej

    2015-07-01

    Chemical Exchange Saturation Transfer (CEST) magnetic resonance experiments have become valuable tools in magnetic resonance for the detection of low concentration solutes with far greater sensitivity than direct detection methods. Accurate measures of rates of chemical exchange provided by CEST are of particular interest to biomedical imaging communities where variations in chemical exchange can be related to subtle variations in biomarker concentration, temperature and pH within tissues using MRI. Despite their name, however, traditional CEST methods are not truly selective for chemical exchange and instead detect all forms of magnetization transfer including through-space NOE. This ambiguity crowds CEST spectra and greatly complicates subsequent data analysis. We have developed a Transfer Rate Edited CEST experiment (TRE-CEST) that uses two different types of solute labeling in order to selectively amplify signals of rapidly exchanging proton species while simultaneously suppressing 'slower' NOE-dominated magnetization transfer processes. This approach is demonstrated in the context of both NMR and MRI, where it is used to detect the labile amide protons of proteins undergoing chemical exchange (at rates ⩾ 30 s-1) while simultaneously eliminating signals originating from slower (∼5 s-1) NOE-mediated magnetization transfer processes. TRE-CEST greatly expands the utility of CEST experiments in complex systems, and in-vivo, in particular, where it is expected to improve the quantification of chemical exchange and magnetization transfer rates while enabling new forms of imaging contrast.

  12. Ultrasonography findings of thyroid metastasis in a patient with hepatocellular carcinoma: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Ho; Park, Noh Hyuck; Lim, Jae Hoon; Park, Chan Sub; Seong, Su Ok; Kwon, Tae Jung [Myongji Hospital, Goyang (Korea, Republic of)

    2015-03-15

    Although the thyroid gland is one of the most vascular organs of the body, metastatic disease in the thyroid is encountered infrequently. However, at autopsy, the incidence rate of thyroid metastasis ranges from 1.25% to 24%. The primary sites are the kidney, lung, breast, and gastrointestinal tract. We report a rare case of a hepatocellular carcinoma metastatic to the thyroid gland. The patient had multiple palpable masses in the anterior and left lateral neck along the internal jugular chain on physical examination 9 months after the initial diagnosis of liver tumor. These masses were confirmed as metastasis from hepatocellular carcinoma by ultrasonography-guided 16-G core needle biopsy. We discuss the sonographic findings of thyroid metastasis and their use as an additional aid for differentiating between unknown primary tumor and thyroid metastasis.

  13. The CT diagnose of pleural metastasis tumour

    International Nuclear Information System (INIS)

    Chen Liqun; Han Kaibin; Pan Heng; Huang Xiaoru; Zhou Bingcao; Huang Yuehua

    2007-01-01

    Objective: To discuss the CT characteristic of pleural metastasis tumour,enhance the diagnostic level of pleural metastasis tumour. Methods: Review 30 cases which have been performed CT scan in our hospital during March 2002 to June 2003, which have been approved to pleural metastasis tumour by pathology and clinic. Make use of GE Hispeed.zx/i spiral CT,10mm thickness,10mm increment, l.5 pitch, some of them use 10mm or high resolution mode. All cases have been performed normal scan, 25 cases with contrast scan. Results: The CT representation of pleural metastasis tumour are encapsulated pleural effusion with irregular pleural thickening(56.6%), nodular pleural thickening(46.6%), pleural masses (13.3%), pneumothorax (3.3%), etc. Encapsulated pleural effusion and nodular pleural thickening are 76.6%, use contrast mode to scan pleural pathological changes enhance upon middle level, CT value increment > 20HU, there are 66.6% cases with other chest metastasis symptom, 73.3% primary lesion are pulmonary cancer, and 20% no primary lesion are found. Conclusion: Combine primary lesion history and other chest metastasis symptom, Spiral CT examination can differentiate most of pleural metastasis tumour, but it is difficult to differentiate the cases between with a little pleural effusion or light band pleural thickening and reactive alteration. (authors)

  14. Apalutamide treatment and metastasis-free survival in prostate cancer

    DEFF Research Database (Denmark)

    Smith, Matthew R.; Saad, Fred; Chowdhury, Simon

    2018-01-01

    BACKGROUND Apalutamide, a competitive inhibitor of the androgen receptor, is under development for the treatment of prostate cancer. We evaluated the efficacy of apalutamide in men with nonmetastatic castration-resistant prostate cancer who were at high risk for the development of metastasis....... METHODS We conducted a double-blind, placebo-controlled, phase 3 trial involving men with nonmetastatic castration-resistant prostate cancer and a prostate-specific antigen doubling time of 10 months or less. Patients were randomly assigned, in a 2:1 ratio, to receive apalutamide (240 mg per day...... and 7.0% in the placebo group. The following adverse events occurred at a higher rate with apalutamide than with placebo: rash (23.8% vs. 5.5%), hypothyroidism (8.1% vs. 2.0%), and fracture (11.7% vs. 6.5%). CONCLUSIONS Among men with nonmetastatic castration-resistant prostate cancer, metastasis...

  15. Treatment of metastasis localizations by intratumoral injection of radionuclide microsphere

    International Nuclear Information System (INIS)

    Tuo Peiyu; Pang Yan; Zhu Dianqing; Chang Keli; Zhu Yanjia

    2001-01-01

    Objective: To evaluate the therapeutic effects of radionuclide-labeled microsphere by intratumoral injection into 18 patients with superficial metastasis tumor for treatment. Methods: 18 patients with superficial metastasis were treated with radionuclide-labeled microsphere ( 90 Y-GTMS and 32 P-GTMS) by multi-point intratumoral injection. Each injection dose was 11.1-18.5 MBq/g (tumor). Results: 1 patient was relieved completely, 9 were relieved partly, 5 were improved and 3 kept stable. The total rate of relief and virtual value were 55.6% and 83.3% respectively. Conclusion: Topical treatment by using radionuclide may help diminish the tumor, control its progress and ease the symptoms. Thus it can be used as a supplement of routine treatment of tumors and it should do some work in therapy of malignant tumors in late stages

  16. Bone metastasis pattern in initial metastatic breast cancer: a population-based study

    Directory of Open Access Journals (Sweden)

    Xiong Z

    2018-02-01

    Full Text Available Zhenchong Xiong,1–3,* Guangzheng Deng,1–3,* Xinjian Huang,1–3,* Xing Li,1–3 Xinhua Xie,1–3 Jin Wang,1–3 Zeyu Shuang,1–3 Xi Wang1–3 1Department of Breast Surgery, Sun Yat-sen University Cancer Center, Guangzhou, China; 2State Key Laboratory of Oncology in Southern China, Guangzhou, China; 3Collaborative Innovation Center for Cancer Medicine, Guangzhou, China *These authors contributed equally to this work Purpose: Bone is one of the most common sites of breast cancer metastasis, and population-based studies of patients with bone metastasis in initial metastatic breast cancer (MBC are lacking. Materials and methods: From 2010 to 2013, 245,707 breast cancer patients and 8901 patients diagnosed with initial bone metastasis were identified by Surveillance, Epidemiology, and End Results database of the National Cancer Institute. Multivariate logistic and Cox regression were used to identify predictive factors for the presence of bone metastasis and prognosis factors. Kaplan–Meier method and log-rank test were used for survival analysis. Results: Eight thousand nine hundred one patients with initial MBC had bone involvement, accounting for 3.6% of the entire cohort and 62.5% of the patients with initial MBC. Also, 70.5% of patients with bone metastasis were hormone receptor (HR positive (HR+/human epidermal growth factor receptor 2 [HER2]−: 57.6%; HR+/HER2+: 12.9%. Patients with initial bone metastasis had a better 5-year survival rate compared to those with initial brain, liver, or lung metastasis. HR+/HER2− and HR+/HER2+ breast cancer had a propensity of bone metastasis in the entire cohort and were correlated with better prognosis in patients with initial bone metastasis. Local surgery had significantly improved overall survival in initial MBC patients with bone metastasis. Conclusion: Our study has provided population-based estimates of epidemiologic characteristics and prognosis in patients with bone metastasis at the time of

  17. Sleep Apnoea Detection in Single Channel ECGs by Analyzing Heart Rate Dynamics

    National Research Council Canada - National Science Library

    Zywietz, C

    2001-01-01

    .... Our analysis is based on spectral components of heart rate variability. Frequency analysis was performed using Fourier and wavelet transformation with appropriate application of the Hilbert transform...

  18. [Detection rates of overweight and obesity in children and adolescents with different ethnicities in Xinjiang Uigur areas].

    Science.gov (United States)

    Li, Haixia; Li, Xiaomei; Tao, Jing; Ma, Yitong; Yang, Yining; Liu, Fen; Chen, Bangdang; Xie, Xiang; Yang, Hong

    2014-01-01

    To investigate the detection rates of overweight and obesity among Han,Uygur and Kazakh Children and adolescents in Xinjiang. Random samples were used to analyze the detection rates on overweight and obesity based on data from Han,Uygur and Kazakh Children and adolescents aged 7-14 years from 3 regions-Hetian, Kashi and Fuhai prefectures in Xinjiang Uygur Autonomous Region. Anthropometric data including weight and height was collected. Overweight and obesity were defined according to body mass index [BMI, weight (kg)/height (m²)] cutoffs recommended by the Chinese Working Group on Obesity for Children (WGOC)aged 7-14 years. The present study was performed in 11 894 Han, Uygur and Kazakh Children and adolescents aged 7-14 years. The overall prevalence rates of overweight and obesity were 5.6% and 2.9% respectively, which the difference between male and female was significant (χ² = 39.765, P overweight and obesity rate showed differences, with detection rate of overweight among Kazakh students was 12.0% , higher than the other ethnic groups. The obesity detection rate was 7.2% among Han students, which was the highest of the three ethnic groups, with differences statistically significant(χ² = 363.885, P overweight and obesity decreased with increasing age in various ethnic groups, showing a clear downward trend, with the peak at 7-9 year-olds and the difference was statistically significant(χ² = 101.479, P overweight and obesity among children and adolescents were significantly lower in Xinjiang Uygur Autonomous Region than the national average level, with differences also seen in different ethnic, gender and age groups.

  19. The Diurnal Variation of the Wimp Detection Event Rates in Directional Experiments

    CERN Document Server

    Vergados, J D

    2009-01-01

    The recent WMAP data have confirmed that exotic dark matter together with the vacuum energy (cosmological constant) dominate in the flat Universe. Modern particle theories naturally provide viable cold dark matter candidates with masses in the GeV-TeV region. Supersymmetry provides the lightest supersymmetric particle (LSP), theories in extra dimensions supply the lightest Kaluza-Klein particle (LKP) etc. The nature of dark matter can only be unraveled only by its direct detection in the laboratory. All such candidates will be called WIMPs (Weakly Interacting Massive Particles). In any case the direct dark matter search, which amounts to detecting the recoiling nucleus, following its collision with WIMP, is central to particle physics and cosmology. In this work we briefly review the theoretical elements relevant to the direct dark matter detection experiments, paying particular attention to directional experiments. i.e experiments in which, not only the energy but the direction of the recoiling nucleus is ob...

  20. Pituitary metastasis of hepatocellular carcinoma presenting with panhypopituitarism: a case report.

    Science.gov (United States)

    Tanaka, Tomoko; Hiramatsu, Katsushi; Nosaka, Takuto; Saito, Yasushi; Naito, Tatsushi; Takahashi, Kazuto; Ofuji, Kazuya; Matsuda, Hidetaka; Ohtani, Masahiro; Nemoto, Tomoyuki; Suto, Hiroyuki; Yamamoto, Tatsuya; Kimura, Hirohiko; Nakamoto, Yasunari

    2015-11-06

    Metastasis to the pituitary gland is extremely rare and is often detected incidentally by symptoms associated with endocrine dysfunction. Breast and lung cancer are the most common primary metastasizing to pituitary gland. Metastasis from hepatocellular carcinoma to the pituitary gland is extremely rare, with only 10 cases having been previously reported. We present here the first case of pituitary metastasis of hepatocellular carcinoma presenting with panhypopituitarism diagnosed by magnetic resonance imaging. We report the case of an 80-year-old Japanese woman who presented with the sudden onset of hypotension and bradycardia after having previously been diagnosed with hepatocellular carcinoma. Based on low levels of pituitary hormones, she was diagnosed with panhypopituitarism caused by metastasis of the hepatocellular carcinoma to the pituitary gland. Magnetic resonance imaging with arterial spin-labeling was effective in the differential diagnosis of the intrasellar tumor. The patient died despite hormone replacement therapy because of hypovolemic shock. Metastasis to the pituitary gland causes various non-specific symptoms, so it is difficult to diagnose. The present case emphasizes the importance of diagnostic imaging in identifying these metastases. Clinicians should consider the possibility of pituitary metastasis in patients with malignant tumors who demonstrate hypopituitarism.

  1. Pituitary metastasis of hepatocellular carcinoma presenting with panhypopituitarism: a case report

    International Nuclear Information System (INIS)

    Tanaka, Tomoko; Hiramatsu, Katsushi; Nosaka, Takuto; Saito, Yasushi; Naito, Tatsushi; Takahashi, Kazuto; Ofuji, Kazuya; Matsuda, Hidetaka; Ohtani, Masahiro; Nemoto, Tomoyuki; Suto, Hiroyuki; Yamamoto, Tatsuya; Kimura, Hirohiko; Nakamoto, Yasunari

    2015-01-01

    Metastasis to the pituitary gland is extremely rare and is often detected incidentally by symptoms associated with endocrine dysfunction. Breast and lung cancer are the most common primary metastasizing to pituitary gland. Metastasis from hepatocellular carcinoma to the pituitary gland is extremely rare, with only 10 cases having been previously reported. We present here the first case of pituitary metastasis of hepatocellular carcinoma presenting with panhypopituitarism diagnosed by magnetic resonance imaging. We report the case of an 80-year-old Japanese woman who presented with the sudden onset of hypotension and bradycardia after having previously been diagnosed with hepatocellular carcinoma. Based on low levels of pituitary hormones, she was diagnosed with panhypopituitarism caused by metastasis of the hepatocellular carcinoma to the pituitary gland. Magnetic resonance imaging with arterial spin-labeling was effective in the differential diagnosis of the intrasellar tumor. The patient died despite hormone replacement therapy because of hypovolemic shock. Metastasis to the pituitary gland causes various non-specific symptoms, so it is difficult to diagnose. The present case emphasizes the importance of diagnostic imaging in identifying these metastases. Clinicians should consider the possibility of pituitary metastasis in patients with malignant tumors who demonstrate hypopituitarism

  2. Metastasis of Lung Adenocarcinoma to the Gingiva: A Rare Case Report

    Directory of Open Access Journals (Sweden)

    M. Rajini Kanth

    2015-05-01

    Full Text Available Metastatic tumors account for 1% of all oral malignancies. Metastasis to jaw bones is common, particularly in the mandible, rare in the oral soft tissues, and account for only 0.1% of oral malignancies. The majority of metastatic cases (70% reported in the literature have primary tumors located in the lung, breast, kidney, and colon. Metastasis is a biological complex process that involves detachment from the surrounding cells, regulation of cell motility, invasion, survival, proliferation, and evasion of the immune system. Clinical presentation of metastatic tumors is variable, which may create diagnostic dilemma or may lead to erroneous diagnosis. Metastatic tumors clinically mimic as dental infections. Metastasis to the oral soft tissue from lung cancer, especially gingiva is a rare condition. Metastasis to the gingiva can affect the oral function, speech, and nutrition. Most of the cases in the literature reported that lesion presented in oral soft tissues before the diagnosis of primary tumors. Here we report a case of 62-year-old male patient with metastasis from lung to the gingiva, where the metastasis was detected before primary tumor.

  3. The effectiveness of PET for the distinction of perirectal lymph node metastasis of rectal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Dae Yong; Choi, Chang Woon

    1999-12-01

    If the effectiveness for the distinction of perirectal lymph node metastasis is proved to be higher than the previous conventional detection methods, likewise CT and endorectal ultrasound, more precise and more specific information will be taken by this new modality. Preoperative biopsy-proven rectal adenocarcinoma patients with or without distant metastasis were included for this study. For the effectiveness of PET for the distinction of perirectal lymph node metastasis, CT and endorectal ultrasound versus findings of perirectal lymph node status were compared with permanent pathology results. The findings of preoperative conventional methods showed that 8 patients had not preirectal lymph node metastasis and 6 patients and perirectal lymph node metastasis. The accuracy of conventional methods was 50 % compared with 37.5 % of that of PET in the case of 8 patients. In the case of 6 patients, accuracy was 100 % in the conventional methods and 66.7 % in PET study. Overall sensitivity and specificity were 60 % and 100 % in the conventional methods and 40 % and 75 % in PET study respectively. Therefore, PET is not effective for the distinction of L/N metastasis of rectal cancer comparing with conventional methods such as CT and ERUS preoperatively.

  4. Concurrent whole brain radiotherapy and bortezomib for brain metastasis

    International Nuclear Information System (INIS)

    Lao, Christopher D; Hamstra, Daniel; Lawrence, Theodore; Hayman, James; Redman, Bruce G; Friedman, Judah; Tsien, Christina I; Normolle, Daniel P; Chapman, Christopher; Cao, Yue; Lee, Oliver; Schipper, Matt; Van Poznak, Catherine

    2013-01-01

    Survival of patients with brain metastasis particularly from historically more radio-resistant malignancies remains dismal. A phase I study of concurrent bortezomib and whole brain radiotherapy was conducted to determine the tolerance and safety of this approach in patients with previously untreated brain metastasis. A phase I dose escalation study evaluated the safety of bortezomib (0.9, 1.1, 1.3, 1.5, and 1.7 mg/m 2 ) given on days 1, 4, 8 and 11 of whole brain radiotherapy. Patients with confirmed brain metastasis were recruited for participation. The primary endpoint was the dose-limiting toxicity, defined as any ≥ grade 3 non-hematologic toxicity or grade ≥ 4 hematologic toxicity from the start of treatment to one month post irradiation. Time-to-Event Continual Reassessment Method (TITE-CRM) was used to determine dose escalation. A companion study of brain diffusion tensor imaging MRI was conducted on a subset of patients to assess changes in the brain that might predict delayed cognitive effects. Twenty-four patients were recruited and completed the planned therapy. Patients with melanoma accounted for 83% of all participants. The bortezomib dose was escalated as planned to the highest dose of 1.7 mg/m 2 /dose. No grade 4/5 toxicities related to treatment were observed. Two patients had grade 3 dose-limiting toxicities (hyponatremia and encephalopathy). A partial or minor response was observed in 38% of patients. Bortezomib showed greater demyelination in hippocampus-associated white matter structures on MRI one month after radiotherapy compared to patients not treated with bortezomib (increase in radial diffusivity +16.8% versus 4.8%; p = 0.0023). Concurrent bortezomib and whole brain irradiation for brain metastasis is well tolerated at one month follow-up, but MRI changes that have been shown to predict delayed cognitive function can be detected within one month of treatment

  5. Construction of radiation - induced metastasis model in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Kuk; Jang, Su Jin; Kang, Sung Wook; Kim, Jae Sung; Hwang, Sang Gu; Kang, Joo Hyun [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2011-05-15

    In treatment of cancer, distant metastases are important limiting factor because an estimated 50% of all cancer patients will develop metastases, and the metastases are major causing of cancer treatment failure. Recently a few reports indicated {gamma}-radiation induced an increase of invasiveness of several cancer cells. In this study, we had tried to show the possibility that radiation could also induce metastasis in vivo system. To prove our hypothesis, we constructed primary tumor by using C6-TL transfectant cell line expressing HSV1-tk and firefly luciferase (fLuc), and then {gamma}-radiation was treated to xenografts locally. Treatment of {gamma}-radiation to primary C6-TL xenografts of mice reduced size of xenografts and elongated survival of mice than those of mock control mice. But we also show that {gamma}-radiation treatment was followed by the growth of dormant metastases in various organs including lung and intestine after 2-4 weeks of {gamma}-radiation treatment. When bioluminescence imaging indicated growth of tumor in organs in mice, we sacrificed the mice and repeat acquired bioluminescence imaging after repeatedly. These images presented tumor growth locations exactly in organs. Because metastatic tumor candidates have morphology of foci, biopsies were performed for histological analysis or PCR analysis to confirm metastases. In most foci, histological analysis indicated several features of typical cancer tissue and PCR analysis showed present of fLuc gene in metastases. Detection of fLuc gene in metastases indicated these foci were originated from primary C6-TL xenografts, and the results suggest that {gamma}-radiation could promote metastasis in vivo as well as in vitro system. Although we need to understand changes of intracellular signaling or physiological phenomena of the radiation-induced metastasis yet, these results also imply that {gamma}-radiation treatment only to cancer patients need to pay attention carefully, and development of new

  6. Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

    Energy Technology Data Exchange (ETDEWEB)

    Starkenburg, Daken J. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Johns, Paul M. [Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611, USA; Detection Systems Group, Pacific Northwest National Laboratory, Richland, Washington 99354, USA; Baciak, James E. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Nuclear Engineering Program, University of Florida, Gainesville, Florida 32611, USA; Nino, Juan C. [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA; Xue, Jiangeng [Department of Materials Science and Engineering, University of Florida, Gainesville, Florida 32611, USA

    2017-12-14

    Developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C60, AlPcCl:C70, and P3HT:PC61BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.28 µGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy-1 cm-2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

  7. Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

    Science.gov (United States)

    Starkenburg, Daken J.; Johns, Paul M.; Baciak, James E.; Nino, Juan C.; Xue, Jiangeng

    2017-12-01

    Developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C60, AlPcCl:C70, and P3HT:PC61BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.18 μGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy-1 cm-2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

  8. Transfer Rate Edited experiment for the selective detection of Chemical Exchange via Saturation Transfer (TRE-CEST).

    Science.gov (United States)

    Friedman, Joshua I; Xia, Ding; Regatte, Ravinder R; Jerschow, Alexej

    2015-07-01

    Chemical Exchange Saturation Transfer (CEST) magnetic resonance experiments have become valuable tools in magnetic resonance for the detection of low concentration solutes with far greater sensitivity than direct detection methods. Accurate measures of rates of chemical exchange provided by CEST are of particular interest to biomedical imaging communities where variations in chemical exchange can be related to subtle variations in biomarker concentration, temperature and pH within tissues using MRI. Despite their name, however, traditional CEST methods are not truly selective for chemical exchange and instead detect all forms of magnetization transfer including through-space NOE. This ambiguity crowds CEST spectra and greatly complicates subsequent data analysis. We have developed a Transfer Rate Edited CEST experiment (TRE-CEST) that uses two different types of solute labeling in order to selectively amplify signals of rapidly exchanging proton species while simultaneously suppressing 'slower' NOE-dominated magnetization transfer processes. This approach is demonstrated in the context of both NMR and MRI, where it is used to detect the labile amide protons of proteins undergoing chemical exchange (at rates⩾30s(-1)) while simultaneously eliminating signals originating from slower (∼5s(-1)) NOE-mediated magnetization transfer processes. TRE-CEST greatly expands the utility of CEST experiments in complex systems, and in-vivo, in particular, where it is expected to improve the quantification of chemical exchange and magnetization transfer rates while enabling new forms of imaging contrast. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. The impact of ambient dose rate measuring network and precipitation radar system for detection of environmental radioactivity released by accident

    International Nuclear Information System (INIS)

    Bleher, M; Stoehlker, U.

    2003-01-01

    For the surveillance of environmental radioactivity, the German measuring network of BfS consists of more than 2000 stations where the ambient gamma dose rate is continuously measured. This network is a helpful tool to detect and localise enhanced environmental contamination from artificial radionuclides. The threshold for early warning is so low, that already an additional dose rate contribution of 0,07 μGy/h is detectable. However, this threshold is frequently exceeded due to precipitation events caused by washout of natural activity in air. Therefore, the precipitation radar system of the German Weather Service provides valuable information on the problem, whether the increase of the ambient dose rate is due to natural or man-made events. In case of an accidental release, the data of this radar system show small area precipitation events and potential local hot spots not detected by the measuring network. For the phase of cloud passage, the ambient dose rate measuring network provides a reliable database for the evaluation of the current situation and its further development. It is possible to compare measured data for dose rate with derived intervention levels for countermeasures like ''sheltering''. Thus, critical regions can be identified and it is possible to verify implemented countermeasures. During and after this phase of cloud passage the measured data of the monitoring network help to adapt the results of the national decision support systems PARK and RODOS. Therefore, it is necessary to derive the actual additional contribution to the ambient dose rate. Map representations of measured dose rate are rapidly available and helpful to optimise measurement strategies of mobile systems and collection strategies for samples of agricultural products. (orig.)

  10. Accuracy rate of pregnancy detection in dairy cow by measuring the early pregnancy factor

    Directory of Open Access Journals (Sweden)

    S Mosaferi

    2007-08-01

    Full Text Available Early pregnancy factor (EPF a protein with immunosuppressive properties can be detected in the serum of most domestic animals at early pregnancy. In this study, pregnancy detection in 41 dairy cows following artificial insemination was evaluated by detecting EPF in blood serum using the rosette inhibition test (RIT. The amount of EPF activity 1-3 and 4-7 days after artificial insemination of cows was measured by RIT. Pregnancies were confirmed 45-60 days after insemination by rectal palpation. The results indicated that sensitivity, specificity, positive predictive value, negative predictive value and accuracy of this technique in detecting pregnancy 1-3 days following insemination was 88.88,  66.66,  72.72,  85.71  and  77.77 percent  respectively and RIT titers of above 8 and below 4 were seen in pregnant and non-pregnant animals at this period. The value of the above parameters were 91,  83.83,  83.33,  91  and  87 percent  respectively  4-7  days  after insemination and also RIT titers of above 8 and below 4 were achieved in pregnant and non pregnant cows during this period. The results of this study indicated that there are significant differences in RIT titers between pregnant and non-pregnant cows 1-3 and 4-7 days following artificial insemination (P

  11. Evaluation of the usefulness of smartphone-directed applications for measuring heart rate and arrhythmia detection

    Directory of Open Access Journals (Sweden)

    Michał Witkowski

    2017-12-01

    Conclusions: The majority of the free applications, available for smartphones, are able to measure HR precisely in patients with sinus rhythm, while in patients with AF, the exact measurement is significantly impeded by HR deficits. Only one out of 16 applications was able to measure HR in a patient with AF. None of the available applications could detect AF.

  12. Automatic Atrial Fibrillation Detection: A Novel Approach Using Discrete Wavelet Transform and Heart Rate Variabilit

    DEFF Research Database (Denmark)

    Bruun, Iben H.; Hissabu, Semira M. S.; Poulsen, Erik S.

    2017-01-01

    be used as a screening tool for patients suspected to have AF. The method includes an automatic peak detection prior to the feature extraction, as well as a noise cancellation technique followed by a bagged tree classification. Simulation studies on the MIT-BIH Atrial Fibrillation database was performed...

  13. Dynamic N -occupancy models: estimating demographic rates and local abundance from detection-nondetection data

    Science.gov (United States)

    Sam Rossman; Charles B. Yackulic; Sarah P. Saunders; Janice Reid; Ray Davis; Elise F. Zipkin

    2016-01-01

    Occupancy modeling is a widely used analytical technique for assessing species distributions and range dynamics. However, occupancy analyses frequently ignore variation in abundance of occupied sites, even though site abundances affect many of the parameters being estimated (e.g., extinction, colonization, detection probability). We introduce a new model (“dynamic

  14. Cooperation schemes for rate enhancement in detect-and-forward relay channels

    KAUST Repository

    Benjillali, Mustapha; Szczeciński, Leszek L.; Alouini, Mohamed-Slim

    2010-01-01

    an adaptive cooperation scheme based on the maximization of the information rate at the destination which needs to observe only the average signal-to-noise ratios of direct and relaying links. ©2010 IEEE.

  15. Heart rate variability, sleep, and the early detection of post-traumatic stress disorder

    NARCIS (Netherlands)

    van Boxtel, Geert J.M.; Cluitmans, Pierre J.M.; Raymann, Roy J.E.M.; Ouwerkerk, Martin; Denissen, Ad J.M.; Dekker, Marian K.J.; Sitskoorn, Margriet M.; Vermetten, E.; Germain, A.; Neylan, T.C.

    2017-01-01

    Measures of heart rate variability (HRV) are sensitive indices of autonomic nervous system functioning, capable of distinguishing activity of its two constituent branches, the sympathetic and parasympathetic nervous systems. As such, these measures are possibly useful as early markers of

  16. Molecular biology of breast cancer metastasis: Genetic regulation of human breast carcinoma metastasis

    International Nuclear Information System (INIS)

    Welch, Danny R; Steeg, Patricia S; Rinker-Schaeffer, Carrie W

    2000-01-01

    The present is an overview of recent data that describes the genetic underpinnings of the suppression of cancer metastasis. Despite the explosion of new information about the genetics of cancer, only six human genes have thus far been shown to suppress metastasis functionally. Not all have been shown to be functional in breast carcinoma. Several additional genes inhibit various steps of the metastatic cascade, but do not necessarily block metastasis when tested using in vivo assays. The implications of this are discussed. Two recently discovered metastasis suppressor genes block proliferation of tumor cells at a secondary site, offering a new target for therapeutic intervention

  17. Leptomeningeal metastasis mimicking Chronic Subdural Hematoma

    Directory of Open Access Journals (Sweden)

    Jain Saurabh

    2017-12-01

    Full Text Available The presentation of Leptomeningeal Metastasis varies widely. It can also present a condition very similar to Chronic Subdural Hematoma. One should have a low threshold for suspicion while diagnosing such conditions to avoid catastrophic events.

  18. Leptomeningeal metastasis mimicking Chronic Subdural Hematoma

    OpenAIRE

    Jain Saurabh

    2017-01-01

    The presentation of Leptomeningeal Metastasis varies widely. It can also present a condition very similar to Chronic Subdural Hematoma. One should have a low threshold for suspicion while diagnosing such conditions to avoid catastrophic events.

  19. Colorectal cancer presenting as bone metastasis

    Directory of Open Access Journals (Sweden)

    M C Suresh Babu

    2017-01-01

    Conclusions: In this study, the patients of colorectal cancer presenting with bone metastasis were of male sex and younger age. The factors that were associated with reduced survival were extraosseous and liver involvement.

  20. Isolated malignant melanoma metastasis to the pancreas

    DEFF Research Database (Denmark)

    Larsen, Anne K; Krag, Christen; Geertsen, Poul

    2013-01-01

    SUMMARY: Malignant melanomas rarely develop isolated pancreatic metastases. We describe a unique patient who is still alive 22 years following an isolated pancreatic melanoma metastasis, and we review the sparse literature in the field....

  1. Internet addiction detection rate among college students in the People's Republic of China: a meta-analysis.

    Science.gov (United States)

    Shao, Yao-Jun; Zheng, Tong; Wang, Yan-Qiu; Liu, Ling; Chen, Yan; Yao, Ying-Shui

    2018-01-01

    With the development of economy and technology, the Internet is becoming more and more popular. Internet addiction has gradually become a serious issue in public health worldwide. The number of Internet users in China has reached 731 million, with an estimated 24 million adolescents determined as having Internet addiction. In this meta-analysis, we attempted to estimate the prevalence of Internet addiction among College Students in the People's Republic of China in order to improve the mental health level of college students and provide evidence for the prevention of Internet addiction. Eligible articles about the prevalence of Internet addiction among college students in China published between 2006 and 2017 were retrieved from online Chinese periodicals, the full-text databases of Wan Fang, VIP, and the Chinese National Knowledge Infrastructure, as well as PubMed. Stata 11.0 was used to perform the analyses. A total of 26 papers were included in the analyses. The overall sample size was 38,245, with 4573 diagnosed with Internet addiction. The pooled detection rate of Internet addiction was 11% (95% confidence interval [CI] 9-13%) among college students in China. The detection rate was higher in male students (16%) than female students (8%). The Internet addiction detection rate was 11% (95% CI 8-14%) in southern areas, 11% (95% CI 7-14%) in northern areas, 13% (95% CI 8-18%) in eastern areas and 9% (95% CI 8-11%) in the mid-western areas. According to different scales, the Internet addiction detection rate was 11% (95% CI 8-15%) using the Young scale and 9% (95% CI 6-11%) using the Chen scale respectively. Cumulative meta analysis showed that the detection rate had a slight upward trend and gradually stabilized in the last 3 years. The pooled Internet addiction detection rate of Chinese college students in out study was 11%, which is higher than in some other countries and strongly demonstrates a worrisome situation. Effective measures should be taken to prevent

  2. Detection rate of serrated polyps and serrated polyposis syndrome in colorectal cancer screening cohorts: a European overview.

    Science.gov (United States)

    IJspeert, J E G; Bevan, R; Senore, C; Kaminski, M F; Kuipers, E J; Mroz, A; Bessa, X; Cassoni, P; Hassan, C; Repici, A; Balaguer, F; Rees, C J; Dekker, E

    2017-07-01

    The role of serrated polyps (SPs) as colorectal cancer precursor is increasingly recognised. However, the true prevalence SPs is largely unknown. We aimed to evaluate the detection rate of SPs subtypes as well as serrated polyposis syndrome (SPS) among European screening cohorts. Prospectively collected screening cohorts of ≥1000 individuals were eligible for inclusion. Colonoscopies performed before 2009 and/or in individuals aged below 50 were excluded. Rate of SPs was assessed, categorised for histology, location and size. Age-sex-standardised number needed to screen (NNS) to detect SPs were calculated. Rate of SPS was assessed in cohorts with known colonoscopy follow-up data. Clinically relevant SPs (regarded as a separate entity) were defined as SPs ≥10 mm and/or SPs >5 mm in the proximal colon. Three faecal occult blood test (FOBT) screening cohorts and two primary colonoscopy screening cohorts (range 1.426-205.949 individuals) were included. Rate of SPs ranged between 15.1% and 27.2% (median 19.5%), of sessile serrated polyps between 2.2% and 4.8% (median 3.3%) and of clinically relevant SPs between 2.1% and 7.8% (median 4.6%). Rate of SPs was similar in FOBT-based cohorts as in colonoscopy screening cohorts. No apparent association between the rate of SP and gender or age was shown. Rate of SPS ranged from 0% to 0.5%, which increased to 0.4% to 0.8% after follow-up colonoscopy. The detection rate of SPs is variable among screening cohorts, and standards for reporting, detection and histopathological assessment should be established. The median rate, as found in this study, may contribute to define uniform minimum standards for males and females between 50 and 75 years of age. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Osthole inhibits bone metastasis of breast cancer

    OpenAIRE

    Wu, Chunyu; Sun, Zhenping; Guo, Baofeng; Ye, Yiyi; Han, Xianghui; Qin, Yuenong; Liu, Sheng

    2017-01-01

    Bone is one of the most common sites for breast cancer metastasis, which greatly contributes to patient morbidity and mortality. Osthole, a major extract from Cnidium monnieri (L.), exhibits many biological and pharmacological activities, however, its potential as a therapeutic agent in the treatment of breast cancer bone metastases remain poorly understood. In this study, we set out to investigate whether osthole could inhibit breast cancer metastasis to bone in mice and clarified the potent...

  4. The cancer diaspora: Metastasis beyond the seed and soil hypothesis.

    Science.gov (United States)

    Pienta, Kenneth J; Robertson, Bruce A; Coffey, Donald S; Taichman, Russell S

    2013-11-01

    Do cancer cells escape the confinement of their original habitat in the primary tumor or are they forced out by ecologic changes in their home niche? Describing metastasis in terms of a simple one-way migration of cells from the primary to the target organs is an insufficient concept to cover the nuances of cancer spread. A diaspora is the scattering of people away from an established homeland. To date, "diaspora" has been a uniquely human term used by social scientists; however, the application of the diaspora concept to metastasis may yield new biologic insights as well as therapeutic paradigms. The diaspora paradigm takes into account, and models, several variables including: the quality of the primary tumor microenvironment, the fitness of individual cancer cell migrants as well as migrant populations, the rate of bidirectional migration of cancer and host cells between cancer sites, and the quality of the target microenvironments to establish metastatic sites. Ecologic scientific principles can be applied to the cancer diaspora to develop new therapeutic strategies. For example, ecologic traps - habitats that lead to the extinction of a species - can be developed to attract cancer cells to a place where they can be better exposed to treatments or to cells of the immune system for improved antigen presentation. Merging the social science concept of diaspora with ecologic and population sciences concepts can inform the cancer field to understand the biology of tumorigenesis and metastasis and inspire new ideas for therapy.

  5. A New Mechanism to Improve the Detection Rate of Shilling Attacks in the Recommender Systems

    Directory of Open Access Journals (Sweden)

    javad nehriri

    2017-12-01

    Full Text Available Recommender systems are widely used, in social networks and online stores, to overcome the problems caused by the large amount of information. Most of these systems use a collaborative filtering method to generate recommendations to the users. But, as in this method users’ feedback is considered for recommendations, it can be significantly erroneous by the malicious people. In other words, there may be some users who open fake profiles and vote one-sided or biased in the system that may cause disturbance in providing proper recommendations to other users. This kind of damage is said to be shiling attacks. If the attackers succeed, the user's trust in the recommender systems will reduce. In recent years, efficient attack detection algorithms have been proposed, but each has its own limitations. In this paper, we use profile-based and item-based algorithms to provide a new mechanism to significantly reduce the detection error for shilling attacks.

  6. Detection unit for measuring dose rate and/or dose of gamma radiation

    International Nuclear Information System (INIS)

    Viererbl, L.

    1987-01-01

    A detection unit is designed consisting of a scintillation detector of the NaI(Tl) type on which there is a correction filter. The filter is an aluminium case in which are placed alternately side by side lead and iron absorption layers. The sensitivity of the detector with this filter is constant for gamma energy within the range 50 to 1300 keV. (M.D.). 2 figs

  7. Breast cancer detection rates using four different types of mammography detectors

    Energy Technology Data Exchange (ETDEWEB)

    Mackenzie, Alistair; Warren, Lucy M.; Dance, David R.; Young, Kenneth C. [Royal Surrey County Hospital, National Coordinating Centre for the Physics in Mammography (NCCPM), Guildford (United Kingdom); University of Surrey, Department of Physics, Guildford (United Kingdom); Wallis, Matthew G. [Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); NIHR Cambridge Biomedical Research Centre, Cambridge Breast Unit, Cambridge (United Kingdom); Cooke, Julie [Jarvis Breast Screening and Diagnostic Centre, Guildford (United Kingdom); Given-Wilson, Rosalind M. [St George' s Healthcare NHS Trust, Department of Radiology, London (United Kingdom); Chakraborty, Dev P. [University of Pittsburgh, Department of Radiology, Pittsburgh, PA (United States); Halling-Brown, Mark D. [Royal Surrey County Hospital, Scientific Computing, Department of Medical Physics, Guildford (United Kingdom); Looney, Padraig T. [Royal Surrey County Hospital, National Coordinating Centre for the Physics in Mammography (NCCPM), Guildford (United Kingdom)

    2016-03-15

    To compare the performance of different types of detectors in breast cancer detection. A mammography image set containing subtle malignant non-calcification lesions, biopsy-proven benign lesions, simulated malignant calcification clusters and normals was acquired using amorphous-selenium (a-Se) detectors. The images were adapted to simulate four types of detectors at the same radiation dose: digital radiography (DR) detectors with a-Se and caesium iodide (CsI) convertors, and computed radiography (CR) detectors with a powder phosphor (PIP) and a needle phosphor (NIP). Seven observers marked suspicious and benign lesions. Analysis was undertaken using jackknife alternative free-response receiver operating characteristics weighted figure of merit (FoM). The cancer detection fraction (CDF) was estimated for a representative image set from screening. No significant differences in the FoMs between the DR detectors were measured. For calcification clusters and non-calcification lesions, both CR detectors' FoMs were significantly lower than for DR detectors. The calcification cluster's FoM for CR NIP was significantly better than for CR PIP. The estimated CDFs with CR PIP and CR NIP detectors were up to 15 % and 22 % lower, respectively, than for DR detectors. Cancer detection is affected by detector type, and the use of CR in mammography should be reconsidered. (orig.)

  8. Clinical outcome for patients of solitary bone only metastasis.

    Science.gov (United States)

    Hosaka, Seiichi; Katagiri, Hirohisa; Honda, Yosuke; Wasa, Junji; Murata, Hideki; Takahashi, Mitsuru

    2016-03-01

    Solitary bone only metastasis (SBOM) is a rare condition in which metastasis is limited to a single skeletal lesion originating from a previously treated or controllable primary lesion. The study objective was to evaluate the clinical features and survival regarding this rare condition and to clarify its treatment strategy. A total of 1453 patients with bone metastasis registered in our hospital database were enrolled. To assess the primary and/or metastatic lesion we used plain X-ray images, CT, MRI and FDG-PET scans as well as bone scans. Among the patients, only 27 (1.8%) had SBOM. The primary cancers responsible for SBOM were lung in seven patients, breast in five, kidney in four, prostate in two, uterus in two and other types in seven. Treatment of SBOM involved resection in four patients, radiotherapy only in 17, radiotherapy in combination with zoledronate in six and chemotherapy with zoledronate in one. Local recurrence did not develop in the four cases treated with resection. However, in-field recurrence was found in 4 of 22 (18%) patients who underwent radiotherapy. All three patients who received >40 Gy did not develop in-field recurrence. The overall and event free survival rates at 5 years were 63% and 41%, respectively. Solitary bone only metastasis should be treated with wide resection or long-course radiotherapy at doses 40-50 Gy to achieve long lasting local tumor control. Copyright © 2015 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.

  9. Cutaneous metastasis: clinicopathological study of 72 patients from a tertiary care center in Lebanon.

    Science.gov (United States)

    El Khoury, Jinane; Khalifeh, Ibrahim; Kibbi, Abdul-Ghani; Abbas, Ossama

    2014-02-01

    Cutaneous metastasis is the result of malignant cell spread from primary malignancy to the skin. This is not uncommon, and rates reported in the literature are as high as 10.4%. To the best of our knowledge, there are no studies assessing the epidemiologic, clinical, and histopathological features of cutaneous metastasis in our region. To assess the clinical and histopathological findings of all patients diagnosed with cutaneous metastasis at the American University of Beirut - Medical Center (AUB-MC) and to compare our findings with those published in the literature. Retrospective clinical and histopathologic evaluation of all cases diagnosed as cutaneous metastasis at AUB-MC between 1992 and 2010. A total of 72 patients (50 females and 22 males) were identified. The mean age at diagnosis was 55.2 years. The most common primary cancer was breast cancer in women and laryngeal cancer in men. The most common clinical presentation was a single nodule in 27% of cases followed by multiple nodules in 23%. Cutaneous metastasis lesions were asymptomatic in the majority. The chest was the most commonly affected site. On microscopy, the majority of metastatic cases were adenocarcinomas (74%). This is, to our knowledge, the first study characterizing the epidemiological, clinical, and histopathological features of cutaneous metastasis in the Lebanese population. The clinical and histopathological features observed were in concordance with the published literature, with minor differences. © 2013 The International Society of Dermatology.

  10. How Well Can We Detect Lineage-Specific Diversification-Rate Shifts? A Simulation Study of Sequential AIC Methods.

    Science.gov (United States)

    May, Michael R; Moore, Brian R

    2016-11-01

    Evolutionary biologists have long been fascinated by the extreme differences in species numbers across branches of the Tree of Life. This has motivated the development of statistical methods for detecting shifts in the rate of lineage diversification across the branches of phylogenic trees. One of the most frequently used methods, MEDUSA, explores a set of diversification-rate models, where each model assigns branches of the phylogeny to a set of diversification-rate categories. Each model is first fit to the data, and the Akaike information criterion (AIC) is then used to identify the optimal diversification model. Surprisingly, the statistical behavior of this popular method is uncharacterized, which is a concern in light of: (1) the poor performance of the AIC as a means of choosing among models in other phylogenetic contexts; (2) the ad hoc algorithm used to visit diversification models, and; (3) errors that we reveal in the likelihood function used to fit diversification models to the phylogenetic data. Here, we perform an extensive simulation study demonstrating that MEDUSA (1) has a high false-discovery rate (on average, spurious diversification-rate shifts are identified [Formula: see text] of the time), and (2) provides biased estimates of diversification-rate parameters. Understanding the statistical behavior of MEDUSA is critical both to empirical researchers-in order to clarify whether these methods can make reliable inferences from empirical datasets-and to theoretical biologists-in order to clarify the specific problems that need to be solved in order to develop more reliable approaches for detecting shifts in the rate of lineage diversification. [Akaike information criterion; extinction; lineage-specific diversification rates; phylogenetic model selection; speciation.]. © The Author(s) 2016. Published by Oxford University Press, on behalf of the Society of Systematic Biologists.

  11. [The related factors of head and neck mocosal melanoma with lymph node metastasis].

    Science.gov (United States)

    Yin, G F; Guo, W; Chen, X H; Huang, Z G

    2017-12-05

    Objective: To investigate the related factors of mucosal melanoma of head and neck with lymph node metastasis for early diagnosis and further treatments. Method: A retrospective analysis of 117 cases of head and neck mucosal malignant melanoma patients which received surgical treatment was performed. Eleven cases of patients with pathologically confirmed lymph node metastasis and 33 cases without lymph node metastasis (1∶3) were randomly selected to analyze. The related factors of lymph node metastasis of head and neck mucosal melanoma patients including age, gender, whether the existence of recurrence, bone invasion, lesion location were analyzed. The single factor and logistic regression analysis were performed, P difference was statistically significant. Result: The lymph node metastasis rate of head and neck mucosal melanoma was 9.40%(11/117), the single factor analysis showed that there were 3 factors to be associated with lymph node metastasis, which was recurrence ( P =0.0000), bone invasion ( P =0.001), primary position ( P =0.007). Recurrence ( P =0.021) was a risk factor for lymph node metastasis according to the Logistic regression analysis, and the impact of bone invasion ( P =0.487) and primary location ( P =0.367) remained to be further explored. Conclusion: The patients of head and neck mucosal melanoma with the presence of recurrent usually accompanied by a further progression of the disease, such as lymph node metastasis, so for recurrent patients should pay special attention to the situation of lymph node and choose the reasonable treatment. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  12. Effect of adding screening ultrasonography to screening mammography on patient recall and cancer detection rates: A retrospective study in Japan

    International Nuclear Information System (INIS)

    Tohno, Eriko; Umemoto, Takeshi; Sasaki, Kyoko; Morishima, Isamu; Ueno, Ei

    2013-01-01

    Purpose: To determine whether adding screening ultrasonography to screening mammography can reduce patient recall rates and increase cancer detection rates. Materials and methods: We analyzed the results of mammography and ultrasonography breast screenings performed at the Total Health Evaluation Center Tsukuba, Japan, between April 2011 and March 2012. We also reviewed the modalities and results of diagnostic examinations from women with mammographic abnormalities who visited the Tsukuba Medical Center Hospital for further testing. Results: Of 11,753 women screened, cancer was diagnosed in 10 (0.22%) of the 4529 participants who underwent mammography alone, 23 (0.37%) of the 6250 participants who underwent ultrasonography alone, and 5 (0.51%) of the 974 participants who underwent mammography and ultrasonography. The recall rate due to mammographic abnormalities was 4.9% for women screened only with mammography and 2.6% for those screened with both modalities. The cancer detection rate was 0.22% for women screened only with mammography (positive predictive value, 4.5%) and 0.31% for those screened with both modalities (positive predictive value, 12.0%). Of the 211 lesions presenting as mammographic abnormalities investigated further, diagnostic ultrasonography found no abnormalities in 63 (29.9%) and benign findings in 69 (33.7%). The rest 36.4% needed mammography, cytological or histological examinations or follow-up in addition to diagnostic ultrasonography. Conclusions: It is possible to reduce the recall rate in screening mammography by combining mammography and ultrasonography for breast screening

  13. Up-regulation of GTPBP4 in colorectal carcinoma is responsible for tumor metastasis

    International Nuclear Information System (INIS)

    Yu, Haitao; Jin, Sufeng; Zhang, Na; Xu, Qi

    2016-01-01

    GTP binding protein 4(GTPBP4), a member of GTP-binding protein family, was previously characterized as a tumor suppressor that regulates and requires merlin to suppress cell proliferation. However, the role of GTPBP4 in the metastasis of colorectal carcinoma (CRC) remains unelucidated. Here, we observed that GTPBP4 was detected at higher levels in CRC metastatic tissues than that in the primary tumor tissues. Notably, up-regulation of GTPBP4 was closely correlated with tumor metastasis in CRCs. Kaplan-Meier and multivariate Cox regression analysis indicated GTPBP4 as an independent prognostic factor for CRC patients (hazard ratio = 2.693, 95% confident interval: 1.193–6.083, p = 0.017). Functional studies established that knockdown of GTPBP4 impeded, whereas ectopic expression of GTPBP4 enhanced cell motility and tumor metastasis in CRC cells. Interestingly, mechanistic investigations suggested that GTPBP4 may disorganize actin cytoskeleton through repressing RhoA signaling. Taken together, our research uncovered that GTPBP4 promotes CRC metastasis by disrupting actin cytoskeleton, which is mediated by the reduced RhoA activity. Strategies targeting GTPBP4 will be promising for CRC patients with metastases. - Highlights: • Up-regulation of GTPBP4 is detected in CRC metastatic tissues and closely correlated with tumor metastasis. • Increase of GTPBP4 is closely associated with poor prognosis. • GTPBP4 promotes cell motility and tumor metastasis in CRC cells. • GTPBP4 induces filamentous actin rearrangement specifically by repressing the activity of RhoA. • GTPBP4 may be a novel therapeutic target for CRC patients with metastasis.

  14. Colour Doppler and microbubble contrast agent ultrasonography do not improve cancer detection rate in transrectal systematic prostate biopsy sampling.

    Science.gov (United States)

    Taverna, Gianluigi; Morandi, Giovanni; Seveso, Mauro; Giusti, Guido; Benetti, Alessio; Colombo, Piergiuseppe; Minuti, Francesco; Grizzi, Fabio; Graziotti, Pierpaolo

    2011-12-01

    What's known on the subject? and What does the study add? Transrectal gray-scale ultrasonography guided prostate biopsy sampling is the method for diagnosing prostate cancer (PC) in patients with an increased prostate specific antigen level and/or abnormal digital rectal examination. Several imaging strategies have been proposed to optimize the diagnostic value of biopsy sampling, although at the first biopsy nearly 10-30% of PC still remains undiagnosed. This study compares the PC detection rate when employing Colour Doppler ultransongraphy with or without the injection of SonoVue™ microbubble contrast agent, versus the transrectal ultrasongraphy-guided systematic biopsy sampling. The limited accuracy, sensitivity, specificity and the additional cost of using the contrast agent do not justify its routine application in PC detection. • To compare prostate cancer (PC) detection rate employing colour Doppler ultrasonography with or without SonoVue™ contrast agent with transrectal ultrasonography-guided systematic biopsy sampling. • A total of 300 patients with negative digital rectal examination and transrectal grey-scale ultrasonography, with PSA values ranging between 2.5 and 9.9 ng/mL, were randomized into three groups: 100 patients (group A) underwent transrectal ultrasonography-guided systematic bioptic sampling; 100 patients (group B) underwent colour Doppler ultrasonography, and 100 patients (group C) underwent colour Doppler ultrasonography before and during the injection of SonoVue™. • Contrast-enhanced targeted biopsies were sampled into hypervascularized areas of peripheral, transitional, apical or anterior prostate zones. • All the patients included in Groups B and C underwent a further 13 systematic prostate biopsies. The cancer detection rate was calculated for each group. • In 88 (29.3%) patients a histological diagnosis of PC was made, whereas 22 (7.4%) patients were diagnosed with high-grade prostatic intraepithelial

  15. Alveolar Soft Part Sarcoma Presenting as Hypervascular Adrenal Metastasis

    Science.gov (United States)

    Goroshi, Manjunath; Lila, Anurag R.; Bandgar, Tushar; Shah, Nalini S.

    2018-01-01

    Hypervascular adrenal masses include pheochromocytoma, metastases caused by clear renal cell carcinoma/hepatocellular carcinoma. Alveolar soft part sarcoma (ASPS) causing hypervascular metastases is not described in the literature. Here, we describe the first case of ASPS presenting as hypervascular metastasis. Our case was a 23-year-old male incidentally detected right adrenal mass during the evaluation of pain in the abdomen. On computed tomography (CT), adrenal mass showed bright enhancement in early arterial phase (unenhanced Hounsfield unit [HU]-45.3; arterial phase HU-158.2). 18- flurodeoxyglucose positron emission tomography/CT showed multiple lesions and was confirmed histologically to be due to ASPS. PMID:29398970

  16. THE DETECTION RATE OF EARLY UV EMISSION FROM SUPERNOVAE: A DEDICATED GALEX/PTF SURVEY AND CALIBRATED THEORETICAL ESTIMATES

    Energy Technology Data Exchange (ETDEWEB)

    Ganot, Noam; Gal-Yam, Avishay; Ofek, Eran O.; Sagiv, Ilan; Waxman, Eli; Lapid, Ofer [Department of Particle Physics and Astrophysics, Faculty of Physics, The Weizmann Institute of Science, Rehovot 76100 (Israel); Kulkarni, Shrinivas R.; Kasliwal, Mansi M. [Cahill Center for Astrophysics, California Institute of Technology, Pasadena, CA 91125 (United States); Ben-Ami, Sagi [Smithsonian Astrophysical Observatory, Harvard-Smithsonian Ctr. for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Chelouche, Doron; Rafter, Stephen [Physics Department, Faculty of Natural Sciences, University of Haifa, 31905 Haifa (Israel); Behar, Ehud; Laor, Ari [Physics Department, Technion Israel Institute of Technology, 32000 Haifa (Israel); Poznanski, Dovi; Nakar, Ehud; Maoz, Dan [School of Physics and Astronomy, Tel Aviv University, 69978 Tel Aviv (Israel); Trakhtenbrot, Benny [Institute for Astronomy, ETH Zurich, Wolfgang-Pauli-Strasse 27 Zurich 8093 (Switzerland); Neill, James D.; Barlow, Thomas A.; Martin, Christofer D., E-mail: noam.ganot@gmail.com [California Institute of Technology, 1200 East California Boulevard, MC 278-17, Pasadena, CA 91125 (United States); Collaboration: ULTRASAT Science Team; WTTH consortium; GALEX Science Team; Palomar Transient Factory; and others

    2016-03-20

    The radius and surface composition of an exploding massive star, as well as the explosion energy per unit mass, can be measured using early UV observations of core-collapse supernovae (SNe). We present the first results from a simultaneous GALEX/PTF search for early ultraviolet (UV) emission from SNe. Six SNe II and one Type II superluminous SN (SLSN-II) are clearly detected in the GALEX near-UV (NUV) data. We compare our detection rate with theoretical estimates based on early, shock-cooling UV light curves calculated from models that fit existing Swift and GALEX observations well, combined with volumetric SN rates. We find that our observations are in good agreement with calculated rates assuming that red supergiants (RSGs) explode with fiducial radii of 500 R{sub ⊙}, explosion energies of 10{sup 51} erg, and ejecta masses of 10 M{sub ⊙}. Exploding blue supergiants and Wolf–Rayet stars are poorly constrained. We describe how such observations can be used to derive the progenitor radius, surface composition, and explosion energy per unit mass of such SN events, and we demonstrate why UV observations are critical for such measurements. We use the fiducial RSG parameters to estimate the detection rate of SNe during the shock-cooling phase (<1 day after explosion) for several ground-based surveys (PTF, ZTF, and LSST). We show that the proposed wide-field UV explorer ULTRASAT mission is expected to find >85 SNe per year (∼0.5 SN per deg{sup 2}), independent of host galaxy extinction, down to an NUV detection limit of 21.5 mag AB. Our pilot GALEX/PTF project thus convincingly demonstrates that a dedicated, systematic SN survey at the NUV band is a compelling method to study how massive stars end their life.

  17. Obesity detection rate among primary school students in the People's Republic of China: a meta-analysis

    Directory of Open Access Journals (Sweden)

    Jin Y

    2013-10-01

    Full Text Available Yue-long Jin,* Ling-ling Ding,* Ying-shui Yao, Xiu-li Song, Hui Tang, Lian-ping He, Yan ChenFaculty of Epidemiology and Statistics, School of Public Health, Wannan Medical College, Anhui, People's Republic of China*These authors contributed equally to this workBackground: Obesity has become a major public health problem worldwide. The prevalence of obesity is rising alarmingly among children and adolescents in the People's Republic of China, with an estimated 120 million now in the obese range. It is estimated that 8% of children in the People's Republic of China are obese and 12% are overweight.Methods: Eligible papers on the prevalence of obesity among primary school students in the People's Republic of China and published between 2006 and 2011 were retrieved from PubMed and from online Chinese periodicals, ie, the full-text databases of VIP, the Chinese National Knowledge Infrastructure, and Wan Fang. Meta-Analyst software was used to collate and analyze the detection rates cited in the papers retrieved.Results: After evaluation of the quality of the papers, 25 were finally included, giving a total sample population size for investigation of obesity of 219,763, in which 28,121 cases were detected. Meta-analysis showed that the combined obesity detection rate was 10.4% (95% confidence interval 8.6–12.6 among primary school students in the People's Republic of China, with a higher detection rate in boys (12.6% than in girls (7.2%. The prevalence of obesity was higher in the north (11.8% than in the south (9.5%, east (11.6%, and mid-west (8.0% regions. Obesity defined according to the World Health Organization weight-for-height standard (14.3% was higher than that using age-specific and gender-specific cutoff points for body mass index (9.0%.Conclusion: Our meta-analysis found an obesity prevalence rate of 10.4%, which does not seem as high as previous reports of childhood obesity rates in other countries. However, the prevalence of childhood

  18. Children with Autism Detect Targets at Very Rapid Presentation Rates with Similar Accuracy as Adults

    Science.gov (United States)

    Hagmann, Carl Erick; Wyble, Bradley; Shea, Nicole; LeBlanc, Megan; Kates, Wendy R.; Russo, Natalie

    2016-01-01

    Enhanced perception may allow for visual search superiority by individuals with Autism Spectrum Disorder (ASD), but does it occur over time? We tested high-functioning children with ASD, typically developing (TD) children, and TD adults in two tasks at three presentation rates (50, 83.3, and 116.7 ms/item) using rapid serial visual presentation.…

  19. Annosus Root Disease Hazard Rating, Detection, and Management Strategies in the Southeastern United States

    Science.gov (United States)

    S. A. Alexander

    1989-01-01

    Annosus root disease (ARD), is the major root disease of pines in the southeastern United States where severely affected trees exhibit growth loss. Assessing the potential damage of ARD is essential for making effective disease control and management decisions. A soil hazard rating system developed to identify potential for tree mortality is described. The Annosus...

  20. Nijmegen Observer-Rated Depression scale for detection of depression in nursing home residents.

    NARCIS (Netherlands)

    Leontjevas, R.; Gerritsen, D.L.; Vernooij-Dassen, M.J.F.J.; Teerenstra, S.; Smalbrugge, M.; Koopmans, R.T.C.M.

    2012-01-01

    OBJECTIVE: This study aims to test the accuracy of the Nijmegen Observer-Rated Depression (NORD) scale, a new short scale for screening of depression in nursing home (NH) residents with and without dementia. METHODS: This cross-sectional study with 103 residents with dementia (N = 19 depressed) and

  1. Nijmegen Observer-Rated Depression scale for detection of depression in nursing home residents

    NARCIS (Netherlands)

    Leontjevas, R.; Gerritsen, D.L.; Vernooij-Dassen, M.J.; Teerenstra, S.; Smalbrugge, M.; Koopmans, R.T.

    2012-01-01

    Objective This study aims to test the accuracy of the Nijmegen Observer-Rated Depression (NORD) scale, a new short scale for screening of depression in nursing home (NH) residents with and without dementia. Methods This cross-sectional study with 103 residents with dementia (N = 19 depressed) and 72

  2. DETECTING REGIME SWITCHES IN THE EUR/RON EXCHANGE RATE VOLATILITY

    Directory of Open Access Journals (Sweden)

    Radu Alina-Nicoleta

    2009-05-01

    Full Text Available In the present study we develop and implement a short term exchange rate forecasting methodology using dynamic confidence intervals based on GARCH processes and we analyze whether this methodology can be used to model a regime switch in the volatility of

  3. Evaluating cessation of the type 2 oral polio vaccine by modeling pre- and post-cessation detection rates.

    Science.gov (United States)

    Kroiss, Steve J; Famulare, Michael; Lyons, Hil; McCarthy, Kevin A; Mercer, Laina D; Chabot-Couture, Guillaume

    2017-10-09

    The globally synchronized removal of the attenuated Sabin type 2 strain from the oral polio vaccine (OPV) in April 2016 marked a major change in polio vaccination policy. This change will provide a significant reduction in the burden of vaccine-associated paralytic polio (VAPP), but may increase the risk of circulating vaccine-derived poliovirus (cVDPV2) outbreaks during the transition period. This risk can be monitored by tracking the disappearance of Sabin-like type 2 (SL2) using data from the polio surveillance system. We studied SL2 prevalence in 17 countries in Africa and Asia, from 2010 to 2016 using acute flaccid paralysis surveillance data. We modeled the peak and decay of SL2 prevalence following mass vaccination events using a beta-binomial model for the detection rate, and a Ricker function for the temporal dependence. We found type 2 circulated the longest of all serotypes after a vaccination campaign, but that SL2 prevalence returned to baseline levels in approximately 50days. Post-cessation model predictions identified 19 anomalous SL2 detections outside of model predictions in Afghanistan, India, Nigeria, Pakistan, and western Africa. Our models established benchmarks for the duration of SL2 detection after OPV2 cessation. As predicted, SL2 detection rates have plummeted, except in Nigeria where OPV2 use continued for some time in response to recent cVDPV2 detections. However, the anomalous SL2 detections suggest specific areas that merit enhanced monitoring for signs of cVDPV2 outbreaks. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  4. 3D versus 2D Systematic Transrectal Ultrasound-Guided Prostate Biopsy: Higher Cancer Detection Rate in Clinical Practice

    Directory of Open Access Journals (Sweden)

    Alexandre Peltier

    2013-01-01

    Full Text Available Objectives. To compare prostate cancer detection rates of extended 2D versus 3D biopsies and to further assess the clinical impact of this method in day-to-day practice. Methods. We analyzed the data of a cohort of 220 consecutive patients with no prior history of prostate cancer who underwent an initial prostate biopsy in daily practice due to an abnormal PSA and/or DRE using, respectively, the classical 2D and the new 3D systems. All the biopsies were done by a single experienced operator using the same standardized protocol. Results. There was no significant difference in terms of age, total PSA, or prostate volume between the two groups. However, cancer detection rate was significantly higher using the 3D versus the 2D system, 50% versus 34% (P<0.05. There was no statistically significant difference while comparing the 2 groups in term of nonsignificant cancer detection. Conclusion. There is reasonable evidence demonstrating the superiority of the 3D-guided biopsies in detecting prostate cancers that would have been missed using the 2D extended protocol.

  5. Non-contact acquisition of respiration and heart rates using Doppler radar with time domain peak-detection algorithm.

    Science.gov (United States)

    Xiaofeng Yang; Guanghao Sun; Ishibashi, Koichiro

    2017-07-01

    The non-contact measurement of the respiration rate (RR) and heart rate (HR) using a Doppler radar has attracted more attention in the field of home healthcare monitoring, due to the extremely low burden on patients, unconsciousness and unconstraint. Most of the previous studies have performed the frequency-domain analysis of radar signals to detect the respiration and heartbeat frequency. However, these procedures required long period time (approximately 30 s) windows to obtain a high-resolution spectrum. In this study, we propose a time-domain peak detection algorithm for the fast acquisition of the RR and HR within a breathing cycle (approximately 5 s), including inhalation and exhalation. Signal pre-processing using an analog band-pass filter (BPF) that extracts respiration and heartbeat signals was performed. Thereafter, the HR and RR were calculated using a peak position detection method, which was carried out via LABVIEW. To evaluate the measurement accuracy, we measured the HR and RR of seven subjects in the laboratory. As a reference of HR and RR, the persons wore contact sensors i.e., an electrocardiograph (ECG) and a respiration band. The time domain peak-detection algorithm, based on the Doppler radar, exhibited a significant correlation coefficient of HR of 0.92 and a correlation coefficient of RR of 0.99, between the ECG and respiration band, respectively.

  6. Nonlinear Heart Rate Variability features for real-life stress detection. Case study: students under stress due to university examination.

    Science.gov (United States)

    Melillo, Paolo; Bracale, Marcello; Pecchia, Leandro

    2011-11-07

    This study investigates the variations of Heart Rate Variability (HRV) due to a real-life stressor and proposes a classifier based on nonlinear features of HRV for automatic stress detection. 42 students volunteered to participate to the study about HRV and stress. For each student, two recordings were performed: one during an on-going university examination, assumed as a real-life stressor, and one after holidays. Nonlinear analysis of HRV was performed by using Poincaré Plot, Approximate Entropy, Correlation dimension, Detrended Fluctuation Analysis, Recurrence Plot. For statistical comparison, we adopted the Wilcoxon Signed Rank test and for development of a classifier we adopted the Linear Discriminant Analysis (LDA). Almost all HRV features measuring heart rate complexity were significantly decreased in the stress session. LDA generated a simple classifier based on the two Poincaré Plot parameters and Approximate Entropy, which enables stress detection with a total classification accuracy, a sensitivity and a specificity rate of 90%, 86%, and 95% respectively. The results of the current study suggest that nonlinear HRV analysis using short term ECG recording could be effective in automatically detecting real-life stress condition, such as a university examination.

  7. Astrophysical limitations to the identification of dark matter: Indirect neutrino signals vis-a-vis direct detection recoil rates

    International Nuclear Information System (INIS)

    Serpico, Pasquale D.; Bertone, Gianfranco

    2010-01-01

    A convincing identification of dark matter (DM) particles can probably be achieved only through a combined analysis of different detections strategies, which provides an effective way of removing degeneracies in the parameter space of DM models. In practice, however, this program is made complicated by the fact that different strategies depend on different physical quantities, or on the same quantities but in a different way, making the treatment of systematic errors rather tricky. We discuss here the uncertainties on the recoil rate in direct-detection experiments and on the muon rate induced by neutrinos from dark matter annihilations in the Sun, and we show that, contrarily to the local DM density or overall cross section scale, irreducible astrophysical uncertainties affect the two rates in a different fashion, therefore limiting our ability to reconstruct the parameters of the dark matter particles. By varying within their respective errors astrophysical parameters such as the escape velocity and the velocity dispersion of dark matter particles, we show that the uncertainty on the relative strength of the neutrino and direct-detection signal is as large as a factor of 2 for typical values of the parameters, but can be even larger in some circumstances.

  8. Correlation between expression of extracellular matrix metalloproteinase inducer and matrix metalloproteinase-2 and cervical lymph node metastasis of nasopharyngeal carcinoma.

    Science.gov (United States)

    Huang, Tian; Chen, Mao-Huai; Wu, Ming-Yao; Wu, Xian-Ying

    2013-03-01

    We evaluated the expression of extracellular matrix metalloproteinase inducer (EMMPRIN) and matrix metalloproteinase-2 (MMP-2) in nasopharyngeal carcinoma (NPC) and studied their relationship with cervical lymph node metastasis. Immunohistochemical staining was used to detect the expression of EMMPRIN and MMP-2 in specimens from patients with chronic nasopharyngitis (CN), nonmetastastic NPC (NM-NPC), and lymph node-metastatic NPC (LNM-NPC). The rates of positive EMMPRIN expression in CN, NM-NPC, and LNM-NPC were 13.3%, 30.0%, and 66.7%, respectively. Significant differences were found between the rates in CN and LNM-NPC (p correlated (rs = 0.466; p <0.01). Nasopharyngeal carcinoma cells may attain enhanced metastastic capability through the expression of MMP-2 induced by EMMPRIN.

  9. Implications of Binary Black Hole Detections on the Merger Rates of Double Neutron Stars and Neutron Star–Black Holes

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Anuradha; Arun, K. G.; Sathyaprakash, B. S., E-mail: axg645@psu.edu, E-mail: kgarun@cmi.ac.in, E-mail: bss25@psu.edu [Institute for Gravitation and Cosmos, Physics Department, Pennsylvania State University, University Park, PA 16802 (United States)

    2017-11-01

    We show that the inferred merger rate and chirp masses of binary black holes (BBHs) detected by advanced LIGO (aLIGO) can be used to constrain the rate of double neutron star (DNS) and neutron star–black hole (NSBH) mergers in the universe. We explicitly demonstrate this by considering a set of publicly available population synthesis models of Dominik et al. and show that if all the BBH mergers, GW150914, LVT151012, GW151226, and GW170104, observed by aLIGO arise from isolated binary evolution, the predicted DNS merger rate may be constrained to be 2.3–471.0 Gpc{sup −3} yr{sup −1} and that of NSBH mergers will be constrained to 0.2–48.5 Gpc{sup −3} yr{sup −1}. The DNS merger rates are not constrained much, but the NSBH rates are tightened by a factor of ∼4 as compared to their previous rates. Note that these constrained DNS and NSBH rates are extremely model-dependent and are compared to the unconstrained values 2.3–472.5 Gpc{sup −3} yr{sup −1} and 0.2–218 Gpc{sup −3} yr{sup −1}, respectively, using the same models of Dominik et al. (2012a). These rate estimates may have implications for short Gamma Ray Burst progenitor models assuming they are powered (solely) by DNS or NSBH mergers. While these results are based on a set of open access population synthesis models, which may not necessarily be the representative ones, the proposed method is very general and can be applied to any number of models, thereby yielding more realistic constraints on the DNS and NSBH merger rates from the inferred BBH merger rate and chirp mass.

  10. Implications of Binary Black Hole Detections on the Merger Rates of Double Neutron Stars and Neutron Star–Black Holes

    International Nuclear Information System (INIS)

    Gupta, Anuradha; Arun, K. G.; Sathyaprakash, B. S.

    2017-01-01

    We show that the inferred merger rate and chirp masses of binary black holes (BBHs) detected by advanced LIGO (aLIGO) can be used to constrain the rate of double neutron star (DNS) and neutron star–black hole (NSBH) mergers in the universe. We explicitly demonstrate this by considering a set of publicly available population synthesis models of Dominik et al. and show that if all the BBH mergers, GW150914, LVT151012, GW151226, and GW170104, observed by aLIGO arise from isolated binary evolution, the predicted DNS merger rate may be constrained to be 2.3–471.0 Gpc −3 yr −1 and that of NSBH mergers will be constrained to 0.2–48.5 Gpc −3 yr −1 . The DNS merger rates are not constrained much, but the NSBH rates are tightened by a factor of ∼4 as compared to their previous rates. Note that these constrained DNS and NSBH rates are extremely model-dependent and are compared to the unconstrained values 2.3–472.5 Gpc −3 yr −1 and 0.2–218 Gpc −3 yr −1 , respectively, using the same models of Dominik et al. (2012a). These rate estimates may have implications for short Gamma Ray Burst progenitor models assuming they are powered (solely) by DNS or NSBH mergers. While these results are based on a set of open access population synthesis models, which may not necessarily be the representative ones, the proposed method is very general and can be applied to any number of models, thereby yielding more realistic constraints on the DNS and NSBH merger rates from the inferred BBH merger rate and chirp mass.

  11. Low-Complexity Variable Frame Rate Analysis for Speech Recognition and Voice Activity Detection

    DEFF Research Database (Denmark)

    Tan, Zheng-Hua; Lindberg, Børge

    2010-01-01

    present a low-complexity and effective frame selection approach based on a posteriori signal-to-noise ratio (SNR) weighted energy distance: The use of an energy distance, instead of e.g. a standard cepstral distance, makes the approach computationally efficient and enables fine granularity search......Frame based speech processing inherently assumes a stationary behavior of speech signals in a short period of time. Over a long time, the characteristics of the signals can change significantly and frames are not equally important, underscoring the need for frame selection. In this paper, we......, and the use of a posteriori SNR weighting emphasizes the reliable regions in noisy speech signals. It is experimentally found that the approach is able to assign a higher frame rate to fast changing events such as consonants, a lower frame rate to steady regions like vowels and no frames to silence, even...

  12. Penguin head movement detected using small accelerometers: a proxy of prey encounter rate.

    Science.gov (United States)

    Kokubun, Nobuo; Kim, Jeong-Hoon; Shin, Hyoung-Chul; Naito, Yasuhiko; Takahashi, Akinori

    2011-11-15

    Determining temporal and spatial variation in feeding rates is essential for understanding the relationship between habitat features and the foraging behavior of top predators. In this study we examined the utility of head movement as a proxy of prey encounter rates in medium-sized Antarctic penguins, under the presumption that the birds should move their heads actively when they encounter and peck prey. A field study of free-ranging chinstrap and gentoo penguins was conducted at King George Island, Antarctica. Head movement was recorded using small accelerometers attached to the head, with simultaneous monitoring for prey encounter or body angle. The main prey was Antarctic krill (>99% in wet mass) for both species. Penguin head movement coincided with a slow change in body angle during dives. Active head movements were extracted using a high-pass filter (5 Hz acceleration signals) and the remaining acceleration peaks (higher than a threshold acceleration of 1.0 g) were counted. The timing of head movements coincided well with images of prey taken from the back-mounted cameras: head movement was recorded within ±2.5 s of a prey image on 89.1±16.1% (N=7 trips) of images. The number of head movements varied largely among dive bouts, suggesting large temporal variations in prey encounter rates. Our results show that head movement is an effective proxy of prey encounter, and we suggest that the method will be widely applicable for a variety of predators.

  13. Impact of the use of an endorectal coil for 3 T prostate MRI on image quality and cancer detection rate.

    Science.gov (United States)

    Gawlitza, Josephin; Reiss-Zimmermann, Martin; Thörmer, Gregor; Schaudinn, Alexander; Linder, Nicolas; Garnov, Nikita; Horn, Lars-Christian; Minh, Do Hoang; Ganzer, Roman; Stolzenburg, Jens-Uwe; Kahn, Thomas; Moche, Michael; Busse, Harald

    2017-02-01

    This work aims to assess the impact of an additional endorectal coil on image quality and cancer detection rate within the same patients. At a single academic medical center, this transversal study included 41 men who underwent T2- and diffusion-weighted imaging at 3 T using surface coils only or in combination with an endorectal coil in the same session. Two blinded readers (A and B) randomly evaluated all image data in separate sessions. Image quality with respect to localization and staging was rated on a five-point scale. Lesions were classified according to their prostate imaging reporting and data system (PIRADS) score version 1. Standard of reference was provided by whole-mount step-section analysis. Mean image quality scores averaged over all localization-related items were significantly higher with additional endorectal coil for both readers (p < 0.001), corresponding staging-related items were only higher for reader B (p < 0.001). With an endorectal coil, the rate of correctly detecting cancer per patient was significantly higher for reader B (p < 0.001) but not for reader A (p = 0.219). The numbers of histologically confirmed tumor lesions were rather similar for both settings. The subjectively rated 3-T image quality was improved with an endorectal coil. In terms of diagnostic performance, the use of an additional endorectal coil was not superior.

  14. A study of bone metastasis of cervical carcinoma by bone scintigraphy

    International Nuclear Information System (INIS)

    Okamura, Shinsuke; Okamoto, Yoshiaki; Maeda, Takayoshi; Sano, Takashi; Ueki, Minoru; Sugimoto, Osamu; Sakata, Tsunehiko; Yamasaki, Kouichi; Akagi, Hiroaki

    1985-01-01

    In carrying out bone scintigraphy in 224 cases over the 5 years from June, 1978 to May, 1983 as a part of the post-treatment management of cervical carcinoma. Bone metastases were seen in 12.5% (28 cases) of the subjects, about 6% of the total post-treatment cases of cervical carcinoma in the corresponding period (466 cases). Bone metastases were seen in 9.3% (16/172) of post-operative cases, compared with 23.1% (12/52) of non-operative cases. Bone metastases were not seen in clinical stages Ia through IIa (49 cases) but were seen in IIb or higher stages. Bone metastasis rates by histological type, according to WHO classification, were 12.8% (26/203) in squamous cell carcinoma, 5.9% (1/17) in adenocarcinoma, and 25% (1/4) in adenosquamous carcinoma. Among the squamous cell carcinoma cases, small cell non-keratinizing type had the highest bone metastasis rate (p<0.05). Of 172 post-operative cases, 20.8% (11/53) of those with lymphnode metastasis exhibited bone metastasis, higher than the 4.2% (5/119) in cases without lymphnode metastasis. As to CPL classification, bone metastasis was seen more often in L type (18.8%) than C(0.0%) or P types (6.6%). Our risk classification of 168 cases demonstrated that bone metastasis was not seen in risk I group (74 cases), but was seen in 6.7% (1/17) of risk II group and in 19.0% (15/79) of risk III group. Twenty-eight cases with bone metastasis included 11 cases with local recurrence, 8 with pulmonary metastases, 4 with hepatic metastases and 4 with Virchow's lymphnode metastases. The 28 bone metastasis cases included 10 cases with multiple bone metastases and 5 with only a single bone metastasis. Most bone metastases were seen in the lumbar vertebrae and the pelvic bone. Post-operative cases had more distant metastases than non-operative cases. On diagnosis of bone metastases and 17 of the 28 patients had pain, 6 of the remaining 11 patients developing pain thereafter. (J.P.N.)

  15. Increased Cancer Detection Rate and Variations in the Recall Rate Resulting from Implementation of 3D Digital Breast Tomosynthesis into a Population-based Screening Program

    Science.gov (United States)

    Venkataraman, Shambavi; Phillips, Jordana; Dialani, Vandana; Fein-Zachary, Valerie J.; Prakash, Seema; Slanetz, Priscilla J.; Mehta, Tejas S.

    2016-01-01

    Purpose To compare the recall and cancer detection rates (CDRs) at screening with digital breast tomosynthesis (DBT) with those at screening with two-dimensional (2D) mammography and to evaluate variations in the recall rate (RR) according to patient age, risk factors, and breast density and among individual radiologists at a single U.S. academic medical center. Materials and Methods This institutional review board–approved, HIPAA-compliant prospective study with a retrospective cohort included 85 852 asymptomatic women who presented for breast cancer screening over a 3-year period beginning in 2011. A DBT unit was introduced into the existing 2D mammography screening program, and patients were assigned to the first available machine. Ten breast-subspecialized radiologists interpreted approximately 90% of the examinations. RRs were calculated overall and according to patient age, breast density, and individual radiologist. CDRs were calculated. Single and multiple mixed-effect logistic regression analyses, χ2 tests, and Bonferroni correction were utilized, as appropriate. Results The study included 5703 (6.6%) DBT examinations and 80 149 (93.4%) 2D mammography examinations. The DBT subgroup contained a higher proportion of patients with risk factors for breast cancer and baseline examinations. DBT was used to detect 54.3% more carcinomas (+1.9 per 1000, P < .0018) than 2D mammography. The RR was 7.51% for 2D mammography and 6.10% for DBT (absolute change, 1.41%; relative change, –18.8%; P < .0001). The DBT subgroup demonstrated a significantly lower RR for patients with extremely or heterogeneously dense breasts and for patients in their 5th and 7th decades. Conclusion Implementing DBT into a U.S. breast cancer screening program significantly decreased the screening RR overall and for certain patient subgroups, while significantly increasing the CDR. These findings may encourage more widespread adoption and reimbursement of DBT and facilitate improved patient

  16. arXiv Gravitational wave energy emission and detection rates of Primordial Black Hole hyperbolic encounters

    CERN Document Server

    García-Bellido, Juan

    2018-01-01

    We describe in detail gravitational wave bursts from Primordial Black Hole (PBH) hyperbolic encounters. The bursts are one-time events, with the bulk of the released energy happening during the closest approach, which can be emitted in frequencies that could be within the range of both LIGO (10-1000Hz) and LISA ($10^{-6}-1$ Hz). Furthermore, we correct the results for the power spectrum of hyperbolic encounters found in the literature and present new exact and approximate expressions for the peak frequency of the emission. Note that these GW bursts from hyperbolic encounters between PBH are complementary to the GW emission from the bounded orbits of BHB mergers detected by LIGO, and help breaking degeneracies in the determination of the PBH mass, spin and spatial distributions.

  17. Pulse pile-up in nuclear particle detection systems with rapidly varying counting rates

    International Nuclear Information System (INIS)

    Datlowe, D.W.

    1977-01-01

    Pulse pile-up in nuclear particle detection systems is the distortion of the measured pulse height distribution which occurs when there is a significant probability that more than one particle will arrive within the detector resolving time. This paper treats the problem in cases where the probability of pile-up varies on a time scale comparable to the rise time of the detector system electronics. These variations introduce structure into the pulse height distributions which cannot occur for a time-independent pile-up probability. Three classes of problems which exemplify these effects are as follows: 1) Pile-up rejection circuits. 2) Cascaded nuclear decays, in which the lifetime for emission of a second X-ray is comparable to the detector rise time. 3) Bursts of particles where the intensity is modulated on a time scale comparable to the detector rise time. These problems are solved computationally by an extension of a numerical technique previously developed. (Auth.)

  18. Models for financial crisis detection in Indonesia based on bank deposits, real exchange rate and terms of trade indicators

    Science.gov (United States)

    Sugiyanto; Zukhronah, Etik; Nur Aini, Anis

    2017-12-01

    Several times Indonesia has experienced to face a financial crisis, but the crisis occurred in 1997 had a tremendous impact on the economy and national stability. The impact of the crisis fall the exchange rate of rupiah against the dollar so it is needed the financial crisis detection system. Some data of bank deposits, real exchange rate and terms of trade indicators are used in this paper. Data taken from January 1990 until December 2016 are used to form the models with three state. Combination of volatility and Markov switching models are used to model the data. The result suggests that the appropriate model for bank deposit and terms of trade is SWARCH (3,1), and for real exchange rates is SWARCH (3,2).

  19. Sensitivity of new detection method for ultra-low frequency gravitational waves with pulsar spin-down rate statistics

    Science.gov (United States)

    Yonemaru, Naoyuki; Kumamoto, Hiroki; Takahashi, Keitaro; Kuroyanagi, Sachiko

    2018-04-01

    A new detection method for ultra-low frequency gravitational waves (GWs) with a frequency much lower than the observational range of pulsar timing arrays (PTAs) was suggested in Yonemaru et al. (2016). In the PTA analysis, ultra-low frequency GWs (≲ 10-10 Hz) which evolve just linearly during the observation time span are absorbed by the pulsar spin-down rates since both have the same effect on the pulse arrival time. Therefore, such GWs cannot be detected by the conventional method of PTAs. However, the bias on the observed spin-down rates depends on relative direction of a pulsar and GW source and shows a quadrupole pattern in the sky. Thus, if we divide the pulsars according to the position in the sky and see the difference in the statistics of the spin-down rates, ultra-low frequency GWs from a single source can be detected. In this paper, we evaluate the potential of this method by Monte-Carlo simulations and estimate the sensitivity, considering only the "Earth term" while the "pulsar term" acts like random noise for GW frequencies 10-13 - 10-10 Hz. We find that with 3,000 milli-second pulsars, which are expected to be discovered by a future survey with the Square Kilometre Array, GWs with the derivative of amplitude of about 3 × 10^{-19} {s}^{-1} can in principle be detected. Implications for possible supermassive binary black holes in Sgr* and M87 are also given.

  20. Radioimmunoscintigraphy with monoclonal antibody Technetium-99m-Anti-EGF-Receptor (R3-MAB) for the detection of head and neck tumours, metastasis and recurrence. Final report for the period 15 April 1995 - 15 April 1997

    International Nuclear Information System (INIS)

    Oliva Gonzalez, J.P.

    1998-03-01

    A clinical study was carried out to determine the sensitivity of radioimmunoscintigraphy (RIS) using indigenously produced mouse monoclonal antibody (MAB) against epidermal growth factor receptor in the detection of primary, recurrent and metastatic malignant epithelial tumours of the head and neck region in 13 patients. The MAB was labelled with 99m Tc and imaging was carried out using gamma camera and SPECT. The results were correlated with histopathological findings. RIS gave a sensitivity of 76.9%. This study showed that the indigenously produced MAB can be used for the detection of malignant epithelial tumours in the head and neck region but the MAB will be further characterized to improve its sensitivity in the detection of the neoplasia. (author)

  1. CT study of vertebral metastasis: re-realization of the diagnostic role of the vertebral pedicle sign

    International Nuclear Information System (INIS)

    Meng Quanfei; Jiang Bo; Chen Yingming; Zhang Chaohui

    2000-01-01

    Objective: To investigate the essence of the vertebral pedicle sign of vertebral metastasis on plain film, and to explore the useful CT signs for the diagnosis and differential diagnosis of this tumor. Methods: The CT scans of the spine obtained in 48 patients with vertebral metastases, 19 patients with vertebral tuberculosis, and 11 with vertebral myeloma, were analyzed. The CT findings were correlated with the abnormalities seen on plain films in 34 of the 48 patients (66 vertebrae involved) with vertebral metastasis. Results: 66 vertebrae were involved in the group of metastasis. Of the 28 vertebrae whose vertebral body were completely destroyed, 15 were seen bilateral pedicles destruction; Of the 22 vertebrae with lateral destruction of the body, 16 were noticed unilateral pedicle destruction which located posterior to the involved side of the body. Of the 62 micro-metastatic foci, 56 were scattered in the vertebral body. In the 19 para-spinal soft-tissue masses of vertebral tuberculosis, 5 were noticed calcifications and 12 with postcontrast rings enhancement. The rates of vertebral pedicle destruction of vertebral metastasis and myeloma were not statistically different (X 2 = 0.03, P > 0.50). The locations of destruction of vertebral body in vertebral metastasis and myeloma had no statistical difference (X 2 = 3.52, P > 0.10), but they differed from that in tuberculosis (X 2 = 39.32, P < 0.001). The distribution of lesions within the vertebrae of metastasis and tuberculosis was similar, but was quite different from myeloma. Conclusion: The vertebral metastasis initially occurs in the vertebral body. The vertebral pedicle sign on plain film of vertebral metastasis is the outcome of the posterior invasion of the tumor in the vertebral body, which is of no differential significance for vertebral metastasis and myeloma. Para-spinal soft tissue mass, location of destruction of vertebral body, and the distribution of lesions within the vertebrae may help

  2. [Prediction of lateral lymph node metastasis by magnetic resonance imaging].

    Science.gov (United States)

    Hatano, Satoshi; Kumamoto, Kensuke; Ishibashi, Keiichiro; Ishiguro, Toru; Ohsawa, Tomonori; Okada, Norimichi; Nakata, Hiroshi; Yokoyama, Masaru; Haga, Norihiro; Ishida, Hideyuki

    2010-11-01

    Considering the advantages and disadvantages of lateral lymph node dissection in patients with advanced lower rectal cancer, it would be ideal to select candidates for lateral lymph node dissection by preoperative imaging study including magnetic resonance imaging(MRI). We have reported that the cut-off value of minimal diameter of lateral lymph node could be set at 6 mm for indication of lateral lymph node dissection. In the present study, we evaluated whether it would be appropriate to apply the cut-off value of minimal diameter of lateral lymph node in MRI. Forty-four patients with advanced lower rectal cancer underwent a curative surgery with lateral lymph node dissection or sampling from 1997 to 2009 in our institute. Among them, 25 patients received MRI preoperatively and analyzed. The images were obtained by a sagittal method that was diagonal along sacro-iliac joint with 5 mm thick sections. Lateral lymph node metastasis was detected in 5 cases, one side in 4 cases and both sides in 1 case. The sensitivity, specificity, positive predict value, and accuracy for predicting metastasis was 50%, 90%, 42.9% and 84.8% respectively, when the cut-off value of the minimal diameter was set at 6 mm in MRI. Our results indicated that a 6 mm set as the cut-off value of minimal diameter of lateral lymph node was suitable for the prediction of lateral lymph node metastasis since the accuracy was relatively high (84.8%), though it was hardly to detect metastatic lymph node less than 6 mm.

  3. Prediction of lateral lymph node metastasis by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hatano, Satoshi; Kumamoto, Kensuke; Ishibashi, Keiichiro

    2010-01-01

    Considering the advantages and disadvantages of lateral lymph node dissection in patients with advanced lower rectal cancer, it would be ideal to select candidates for lateral lymph node dissection by preoperative imaging study including magnetic resonance imaging (MRI). We have reported that the cut-off value of minimal diameter of lateral lymph node could be set at 6 mm for indication of lateral lymph node dissection. In the present study, we evaluated whether it would be appropriate to apply the cut-off value of minimal diameter of lateral lymph node in MRI. Forty-four patients with advanced lower rectal cancer underwent a curative surgery with lateral lymph node dissection or sampling from 1997 to 2009 in our institute. Among them, 25 patients received MRI preoperatively and analyzed. The images were obtained by a sagittal method that was diagonal along sacro-iliac joint with 5 mm thick sections. Lateral lymph node metastasis was detected in 5 cases, one side in 4 cases and both sides in 1 case. The sensitivity, specificity, positive predict value, and accuracy for predicting metastasis was 50%, 90%, 42.9% and 84.8% respectively, when the cut-off value of the minimal diameter was set at 6 mm in MRI. Our results indicated that a 6 mm set as the cut-off value of minimal diameter of lateral lymph node was suitable for the prediction of lateral lymph node metastasis since the accuracy was relatively high (84.8%), though it was hardly to detect metastatic lymph node less than 6 mm. (author)

  4. Clinicopathologic characteristics and prognostic factors of 63 gastric cancer patients with metachronous ovarian metastasis

    International Nuclear Information System (INIS)

    Feng, Qiang; Pei, Wei; Zheng, Zhao-Xu; Bi, Jian-Jun; Yuan, Xing-Hua

    2013-01-01

    This study aims to explore the clinicopathologic characteristics and prognostic factors of gastric cancer patients with metachronous ovarian metastasis. Clinicopathologic data were collected from 63 post-operative gastric cancer patients with metachronous ovarian metastasis. The patients were admitted to the Cancer Institute and Hospital, Chinese Academy of Medical Science and Peking Union Medical College between January 1999 and December 2011. A log-rank test was conducted for survival analysis. Possible prognostic factors that affect survival were examined by univariate analysis. A Cox regression model was used for multivariate analysis. The incidence of ovarian metastasis was 3.4% with a mean age of 45 years. Up to 65.1% of the patients were pre-menopausal. The mean interval between ovarian metastasis and primary cancer was 16 months. Lowly differentiated carcinoma ranked first in the primary gastric cancers. The majority of lesions occurred in the serous membrane (87.3%). The metastatic sites included N 2-3 lymph nodes (68.3%), bilateral ovaries (85.7%), and peritoneal membrane (73%). Total resection of metastatic sites was performed (31.7%). The overall median survival was 13.6 months, whereas the overall 1-, 2-, and 3-year survival rates were 52.5%, 22.0%, and 9.8%, respectively. The 5-year survival rate was zero. Univariate analysis showed that the patient prognosis was correlated with metastatic peritoneal seeding, vascular tumor embolus, range of lesion excision, and mode of comprehensive treatment with adjuvant chemotherapy (P<0.05). Multivariate analysis indicated that metastatic peritoneal seeding was an independent prognostic factor for gastric cancer patients with ovarian metastasis (P<0.01). Effective control of peritoneal seeding—induced metastasis is important for improving the prognosis of gastric cancer patients with ovarian metastasis

  5. Tumour exosome integrins determine organotropic metastasis.

    Science.gov (United States)

    Hoshino, Ayuko; Costa-Silva, Bruno; Shen, Tang-Long; Rodrigues, Goncalo; Hashimoto, Ayako; Tesic Mark, Milica; Molina, Henrik; Kohsaka, Shinji; Di Giannatale, Angela; Ceder, Sophia; Singh, Swarnima; Williams, Caitlin; Soplop, Nadine; Uryu, Kunihiro; Pharmer, Lindsay; King, Tari; Bojmar, Linda; Davies, Alexander E; Ararso, Yonathan; Zhang, Tuo; Zhang, Haiying; Hernandez, Jonathan; Weiss, Joshua M; Dumont-Cole, Vanessa D; Kramer, Kimberly; Wexler, Leonard H; Narendran, Aru; Schwartz, Gary K; Healey, John H; Sandstrom, Per; Labori, Knut Jørgen; Kure, Elin H; Grandgenett, Paul M; Hollingsworth, Michael A; de Sousa, Maria; Kaur, Sukhwinder; Jain, Maneesh; Mallya, Kavita; Batra, Surinder K; Jarnagin, William R; Brady, Mary S; Fodstad, Oystein; Muller, Volkmar; Pantel, Klaus; Minn, Andy J; Bissell, Mina J; Garcia, Benjamin A; Kang, Yibin; Rajasekhar, Vinagolu K; Ghajar, Cyrus M; Matei, Irina; Peinado, Hector; Bromberg, Jacqueline; Lyden, David

    2015-11-19

    Ever since Stephen Paget's 1889 hypothesis, metastatic organotropism has remained one of cancer's greatest mysteries. Here we demonstrate that exosomes from mouse and human lung-, liver- and brain-tropic tumour cells fuse preferentially with resident cells at their predicted destination, namely lung fibroblasts and epithelial cells, liver Kupffer cells and brain endothelial cells. We show that tumour-derived exosomes uptaken by organ-specific cells prepare the pre-metastatic niche. Treatment with exosomes from lung-tropic models redirected the metastasis of bone-tropic tumour cells. Exosome proteomics revealed distinct integrin expression patterns, in which the exosomal integrins α6β4 and α6β1 were associated with lung metastasis, while exosomal integrin αvβ5 was linked to liver metastasis. Targeting the integrins α6β4 and αvβ5 decreased exosome uptake, as well as lung and liver metastasis, respectively. We demonstrate that exosome integrin uptake by resident cells activates Src phosphorylation and pro-inflammatory S100 gene expression. Finally, our clinical data indicate that exosomal integrins could be used to predict organ-specific metastasis.

  6. Understanding the biology of urothelial cancer metastasis

    Directory of Open Access Journals (Sweden)

    Takashi Kobayashi

    2016-10-01

    Full Text Available Management of unresectable urothelial cancer (UC has been a clinical challenge for decades. While drug resistance is a key issue, precise understanding of biology of UC metastasis is another challenge for the improvement of treatment outcome of UC patients. Introduction of the cell biology concepts including epithelial-mesenchymal transition (EMT and cancer stemness seems to explain UC metastasis. Molecular genetics based on gene expression profiling, next generation sequencing, and explosion of non-coding RNA world has opened the door to intrinsic molecular subtyping of UC. Next steps include, based on the recently accumulated understanding, the establishment of novel disease models representing UC metastasis in various experimental platforms, particularly in vivo animal systems. Indeed, novel knowledge molecular genetics has not been fully linked to the modeling of UC metastasis. Further understanding of bladder carcinogenesis is needed particularly with regard to cell of origin related to tumor characteristics including driver gene alterations, pathological differentiations, and metastatic ability. Then we will be able to establish better disease models, which will consequently lead us to further understanding of biology and eventually the development of novel therapeutic strategies for UC metastasis.

  7. Clinicopathological features and prognostic evaluation of bone metastasis in triple-negative breast cancer

    Directory of Open Access Journals (Sweden)

    Anqi Luo

    2017-01-01

    Conclusions: Tumor Stage III-IV, multiple BMs, or coexistence of visceral metastasis were associated with poor prognosis for OS in TNBC patients with BM. These associations may contribute to prevention, early detection, and goal-directed treatment of bone metastatic TNBC.

  8. Breast cancer: Early detection - increasing mortality rates; Mammacarcinom: Erfolgreiche Fruehdiagnose, steigende Mortalitaet

    Energy Technology Data Exchange (ETDEWEB)

    Paterok, E M [Universitaets-Frauenklinik, Erlangen (Germany); Siebzehnruebl, E [Universitaets-Frauenklinik, Erlangen (Germany); Schulz-Wendtland, R [Universitaets-Frauenklinik, Erlangen (Germany); Koch, T [Universitaets-Frauenklinik, Erlangen (Germany)

    1995-05-01

    Mammography, sonography and nmr imaging are the tools that will in all probability detect breast cancer at an early stage. NMR imaging is the most recently developed and most sophisticated high-tech method for the diagnosis of disorders of the mammary parenchyma. To ensure a better differentiation between benign and malignant changes, nmr imaging of the breast is carried out following paramagnetic opacification using intravenous gadolinium DTPA. Owing to their angiogenic potential and increased vascular permeability carcinomas are characterized by a significant contrast medium accumulation. The signal intensities of malignant tumours are therefore higher than those of the adjacent supporting and fatty tissues or the intact mammary parenchyma. (orig./VHE) [Deutsch] Die Diagnostik des fruehen Mammacarcinoms gelingt mit Hilfe der Mammographie, Sonographie und Kernspintomographie. Die Kernspintomographie stellt gegenwaertig das neueste und apparatetechnisch aufwendigste Verfahren zur Diagnostik der Mammaparenchymerkrankungen dar. Zur besseren Differenzierung von malignen und benignen Veraenderungen wird die Kernspintomographie der Brust nach intravenoeser Applikation des paramagnetischen Kontrastmittels Gadolinium-DTPA durchgefuehrt. Carcinome zeigen aufgrund ihrer angiogenetischen Potenz und ihrer erhoehten Gefaesswandpermeabilitaet eine signifikante Kontrastmittelanreicherung. Maligne Tumoren stellen sich deshalb signalreicher dar als das umliegende Stuetz-, Fettgewebe und gesundes Mammaparenchym. (orig./VHE)

  9. Development of gas micro-strip chambers for high rate radiation detection and tracking

    CERN Document Server

    Bouclier, Roger; Gaudaen, J; Florent, J J; Ropelewski, Leszek; Sauli, Fabio; Bondar, A E; Groshev, V R; Minakov, G D; Onuchin, A P; Pestov, Yu N; Shekhtman, L I; Sidorov, V A; Dixit, M S; Oakham, G K; Møller, S; Sørensen, G; Uggerhøj, Erik; Brons, S; Brückner, W; Godbersen, M; Heidrich, M; Paul, S; Trombini, A; Werding, R; Armitage, J A; Karlen, D A; Stewart, G; Barasch, E F; McIntyre, P; Pang, Y; Trost, H J; Salomon, M; Breskin, Amos; Chechik, R; Pansky, A; CERN. Geneva. Detector Research and Development Committee

    1992-01-01

    Gas Micro-Strip Chambers (GMSC) are a promising high-rate, high resolution position detector suited for use in high luminosity hadron collider experiments, as general purpose tracker or to improve the performances of pre-shower counters, transition radiation and inner muon detectors. Large GMSC arrays have been included in proposed LHC and SSC experimental setups. The operating characteristics of GMSC make their use very attractive also for detectors at tau/charm/beauty factories, as well as for synchrotron radiation facilities and for medical applications. At the present state of the art, some problems limiting the usefulness of microstrip chambers are the observed gain changes due to charging up of the support, possible long-term degradation due to ageing, limited sizes imposed by fabrication technologies and unavailability of dedicated high-speed, high-density readout electronics. Limited experience exists of operation of GMSC in real experimental conditions, and little if anything is known about performan...

  10. Development of Gas Micro-Strip Chambers for Radiation Detection and Tracking at High Rates

    CERN Multimedia

    2002-01-01

    % RD28 \\\\ \\\\ Micro-Strip Gas Chambers (GMSC) are a promising high rate, high resolution position detector suited for use in high luminosity hadron collider experiments, as general purpose tracker or to improve the performances of preshower counters, transition radiation and inner muon detectors. Large GMSC arrays have been included in proposed LHC and SSC experimental setups. The operating characteristics of GMSC make their use very attractive also for detectors at tau/beauty/charm factories, as well as for synchrotron radiation facilities and medical applications. At the present state of the art, some problems limiting the usefulness of microstrip chambers are the observed gain changes due to charging up of the support, possible long-term degradation due to ageing, limited sizes imposed by fabrication technologies and unavailability of dedicated high-speed, high-density readout electronics. Limited experience exists of operation of GMSC in real experimental conditions, and little if anything is known about p...

  11. SU-G-201-03: Automation of High Dose Rate Brachytherapy Quality Assurance: Development of a Radioluminescent Detection System for Simultaneous Detection of Activity, Timing, and Positioning

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, C; Xing, L; Fahimian, B [Stanford University, Stanford, CA (United States)

    2016-06-15

    Purpose: Accuracy of positioning, timing and activity is of critical importance for High Dose Rate (HDR) brachytherapy delivery. Respective measurements via film autoradiography, stop-watches and well chambers can be cumbersome, crude or lack dynamic source evaluation capabilities. To address such limitations, a single device radioluminescent detection system enabling automated real-time quantification of activity, position and timing accuracy is presented and experimentally evaluated. Methods: A radioluminescent sheet was fabricated by mixing Gd?O?S:Tb with PDMS and incorporated into a 3D printed device where it was fixated below a CMOS digital camera. An Ir-192 HDR source (VS2000, VariSource iX) with an effective active length of 5 mm was introduced using a 17-gauge stainless steel needle below the sheet. Pixel intensity values for determining activity were taken from an ROI centered on the source location. A calibration curve relating intensity values to activity was generated and used to evaluate automated activity determination with data gathered over 6 weeks. Positioning measurements were performed by integrating images for an entire delivery and fitting peaks to the resulting profile. Timing measurements were performed by evaluating source location and timestamps from individual images. Results: Average predicted activity error over 6 weeks was .35 ± .5%. The distance between four dwell positions was determined by the automated system to be 1.99 ± .02 cm. The result from autoradiography was 2.00 ± .03 cm. The system achieved a time resolution of 10 msec and determined the dwell time to be 1.01 sec ± .02 sec. Conclusion: The system was able to successfully perform automated detection of activity, positioning and timing concurrently under a single setup. Relative to radiochromic and radiographic film-based autoradiography, which can only provide a static evaluation positioning, optical detection of temporary radiation induced luminescence enables dynamic

  12. Effect of intra-hepatic arterial infusion chemotherapy for patients with liver metastasis from breast cancer

    International Nuclear Information System (INIS)

    Liu Dezhong; Li Huai; Zeng Huiying; Yang Ling

    2001-01-01

    Objective: To evaluate the efficacy of intra-hepatic arterial infusion chemotherapy for patients with liver metastasis from breast cancer. Methods: 1993-1998 years, Thirty four patients with liver metastasis from breast cancer had received epi-adriamycin, cisplatin, mitomycin and 5-fluorouracil by intrahepatic arterial infusion chemotherapy. Twelve patients had received embolization. Results: Six patients (17.65%) had a complete response, 12 patients (35.29%) had a partial response. The overall response rate was 52.94%. Cumulative survival rates at 1, 2, 3 and 4 years were 56.90%, 25.00%, 5.00% and 5.00% respectively (Kaplan-Meier method). The median overall survival time was 11.5 months. Conclusion: Intra-hepatic arterial infusion chemotherapy is safe and effective for liver metastasis from breast cancer and should be the first choice of treatment for these patients

  13. To use the brief psychiatric rating scale to detect disorganized speech in schizophrenia: Findings from the REAP-AP study

    Directory of Open Access Journals (Sweden)

    Yong Chon Park

    2018-02-01

    Full Text Available Our study aimed to assess the psychometric validity of the conceptual disorganization item and other items of the Brief Psychiatric Rating Scale (BPRS for detecting disorganized speech in patients with schizophrenia. We included 357 schizophrenia patients with disorganized speech and 1082 without disorganized speech from the survey centers in India, Indonesia, Japan, Malaysia, and Taiwan, using the data from the Research on Asian Psychotropic Patterns for Antipsychotics (REAP-AP study. After adjusting the effects of confounding variables, a binary logistic regression model was fitted to identify BPRS items independently associated with disorganized speech. Receiver operating characteristic (ROC curves were used to identify optimum cut-off scores and their sensitivities and specificities for detecting disorganized speech. After adjusting the effects of confounding variables, the fitted binary logistic regression model indicated that conceptual disorganization (P < 0.0001, uncooperativeness (P = 0.010 and excitement (P = 0.001 were independently associated with disorganized speech. The ROC curve revealed that the conceptual disorganization item could accurately detect disorganized speech in patients with schizophrenia both separately and in combination with uncooperativeness and excitement. The subscale for conceptual disorganization, uncooperativeness and excitement items in the BPRS is a promising psychometric tool for detecting disorganized speech.

  14. Pyrosequencing as a tool for the detection of Phytophthora species: error rate and risk of false Molecular Operational Taxonomic Units.

    Science.gov (United States)

    Vettraino, A M; Bonants, P; Tomassini, A; Bruni, N; Vannini, A

    2012-11-01

    To evaluate the accuracy of pyrosequencing for the description of Phytophthora communities in terms of taxa identification and risk of assignment for false Molecular Operational Taxonomic Units (MOTUs). Pyrosequencing of Internal Transcribed Spacer 1 (ITS1) amplicons was used to describe the structure of a DNA mixture comprising eight Phytophthora spp. and Pythium vexans. Pyrosequencing resulted in 16 965 reads, detecting all species in the template DNA mixture. Reducing the ITS1 sequence identity threshold resulted in a decrease in numbers of unmatched reads but a concomitant increase in the numbers of false MOTUs. The total error rate was 0·63% and comprised mainly mismatches (0·25%) Pyrosequencing of ITS1 region is an efficient and accurate technique for the detection and identification of Phytophthora spp. in environmental samples. However, the risk of allocating false MOTUs, even when demonstrated to be low, may require additional validation with alternative detection methods. Phytophthora spp. are considered among the most destructive groups of invasive plant pathogens, affecting thousands of cultivated and wild plants worldwide. Simultaneous early detection of Phytophthora complexes in environmental samples offers an unique opportunity for the interception of known and unknown species along pathways of introduction, along with the identification of these organisms in invaded environments. © 2012 The Authors Letters in Applied Microbiology © 2012 The Society for Applied Microbiology.

  15. A Bone Metastasis Nude Mouse Model Created by Ultrasound Guided Intracardiac Injection of Breast Cancer Cells: the Micro-CT, MRI and Bioluminescence Imaging Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Young Jin; Song, Eun Hye; Kim, Seol Hwa; Song, Ho Taek; Suh, Jin Suck [Yonsei University College of Medicine, Seoul (Korea, Republic of); Choi, Sang Hyun [Korean Minjok Leadership Academy, Heongsung (Korea, Republic of)

    2011-01-15

    The purpose of this study was to develop a nude mouse model of bone metastasis by performing intracardiac injection of breast cancer cells under ultrasonography guidance and we wanted to evaluate the development and the distribution of metastasis in vivo using micro-CT, MRI and bioluminescence imaging. Animal experiments were performed in 6-week-old female nude mice. The animals underwent left ventricular injection of 2x105 MDA-MB-231Bo-Luc cells. After injection of the tumor cells, serial bioluminescence imaging was performed for 7 weeks. The findings of micro-CT, MRI and the histology were correlated with the 'hot' lesions seen on the bioluminescence imaging. Metastasis was found in 62.3% of the animals. Two weeks after intracardiac injection, metastasis to the brain, spine and femur was detected with bioluminescence imaging with an increasing intensity by week 7. Micro-CT scan confirmed multiple osteolytic lesions at the femur, spine and skull. MRI and the histology were able to show metastasis in the brain and extraskeletal metastasis around the femur. The intracardiac injection of cancer cells under ultrasonography guidance is a safe and highly reproducible method to produce bone metastasis in nude mice. This bone metastasis nude mouse model will be useful to study the mechanism of bone metastasis and to validate new therapeutics

  16. Constraints on the bulk Lorentz factor of gamma-ray bursts with the detection rate by Fermi LAT

    Science.gov (United States)

    Chen, Ye; Liu, Ruo-Yu; Wang, Xiang-Yu

    2018-05-01

    The bulk Lorentz factor(Γ) of the outflow is an essential parameter to understanding the physics of gamma-ray burst (GRB). Informations about the Lorentz factors of some individual GRBs have been obtained from the spectral features of the high-energy gamma-ray emissions (>100 MeV), assuming that the spectral breaks or cutoffs are due to the pair-production attenuation (i.e., γγ → e+e-). In this paper, we attempt to interpret the dependence of the LAT detection rate of GRBs on the number of high-energy gamma-rays, taking into account the attenuation effect. We first simulate a long-GRB sample with Monte Carlo method using the luminosity function, rate distribution with redshift and properties of the GRB spectrum. To characterize the distribution of the Lorentz factors, we assume that the Lorentz factors follow the relation Γ =Γ _0E_iso,52k, where Eiso, 52 is the isotropic photon energy in unit of 1052erg. After taking into account the attenuation effect related with the above Lorentz factor distribution, we are able to reproduce the LAT-detected rate of GRBs as the function of the number of gamma-rays for suitable choice of the values of Γ0 and k. The result suggests that the distribution of the bulk Lorentz factor for the majority of GRBs is in the range of 50 - 250.

  17. Risk of lymph node metastasis associated with deeper invasion by early adenocarcinoma of the esophagus and cardia: study based on endoscopic resection specimens

    NARCIS (Netherlands)

    Alvarez Herrero, L.; Pouw, R. E.; van Vilsteren, F. G.; ten Kate, F. J.; Visser, M.; van Berge Henegouwen, M. I.; Weusten, B. L.; Bergman, J. J.

    2010-01-01

    Background: Most risk estimations for lymph node metastasis in adenocarcinoma of the esophagus and cardia (AEC) with invasion into the muscularis mucosae (m3) or submucosa are based on surgical series. This study aimed to correlate the lymph node metastasis rate with m3 and submucosal infiltration

  18. Histopathological studies of lymph node metastasis in patients preoperatively irradiated for gastric cancer

    Energy Technology Data Exchange (ETDEWEB)

    Oshiro, T [Tokyo Medical Coll. (Japan)

    1978-09-01

    Irradiated 197 cases of progressive gastric cancer were compared with non-irradiated 290 cases of progressive gastric cancer as controls. Irradiated cases showed decreases in the rate of metastasis by 13.1%, in the degree of metastasis by 9.1, and in remote metastasis beyond the range of the second lymph node group. Concerning the site of involvement, the cases whose involvement restricted to upper C, middle M, or lower A region showed a decrease in the metastatic rate. In complete extirpation of the regional lymph nodes, irradiated cases showed a decrease in the rate of metastasis into the first and second lymph node groups. In the type, I, II, and III according to Borrmann's classification, the metastatic rate decreased. Concerning the tissue type, the metastatic rate decreased in adenomatous carcinoma and remarkably decreased in simple carcinoma. As regards the size of tumors, the metastatic rate decreased in the tumors smaller than 6.0 cm in diameter and in those larger than 6.0 cm as well. Concerning the depth of the x-ray irradiation, s/sub 1/ and s/sub 2/ decreased the rate of metastasis. The metastatic rate and 5-year survival rate increased in n/sub 1/(+) by 4.5%, in n/sub 2/(+) by 8.4%, and in all the irradiated cases by 12.5%. The degree of x in lesions metastasized into the lymph node increased according to an increase in irradiated dose, although it tended to be slightly milder than that in main lesions. Metachromasia of cancerous lesions metastasized into the lymph node by pH 4.1 TBM staining was negative(-)-slightly positive(+-) in random interstice and strongly positive(+++) in the cancerous interstice.

  19. Sediment-Mass Accumulation Rate and Variability in the East China Sea Detected by GRACE

    Directory of Open Access Journals (Sweden)

    Ya-Chi Liu

    2016-09-01

    Full Text Available The East China Sea (ECS is a region with shallow continental shelves and a mixed oceanic circulation system allowing sediments to deposit on its inner shelf, particularly near the estuary of the Yangtze River. The seasonal northward-flowing Taiwan Warm Current and southward-flowing China Coastal Current trap sediments from the Yangtze River, which are accumulated over time at rates of up to a few mm/year in equivalent water height. Here, we use the Gravity Recovery and Climate Experiment (GRACE gravity products from three data centres to determine sediment mass accumulation rates (MARs and variability on the ECS inner shelf. We restore the atmospheric and oceanic effects to avoid model contaminations on gravity signals associated with sediment masses. We apply destriping and spatial filters to improve the gravity signals from GRACE and use the Global Land Data Assimilation System to reduce land leakage. The GRACE-derived MARs over April 2002–March 2015 on the ECS inner shelf are about 6 mm/year and have magnitudes and spatial patterns consistent with those from sediment-core measurements. The GRACE-derived monthly sediment depositions show variations at time scales ranging from six months to more than two years. Typically, a positive mass balance of sediment deposition occurs in late fall to early winter when the southward coastal currents prevail. A negative mass balance happens in summer when the coastal currents are northward. We identify quasi-biennial sediment variations, which are likely to be caused by quasi-biennial variations in rain and erosion in the Yangtze River basin. We briefly explain the mechanisms of such frequency-dependent variations in the GRACE-derived ECS sediment deposition. There is no clear perturbation on sediment deposition over the ECS inner shelf induced by the Three Gorges Dam. The limitations of GRACE in resolving sediment deposition are its low spatial resolution (about 250 km and possible contaminations by

  20. Inhibitory effect of gene combination in a mouse model of colon cancer with liver metastasis.

    Science.gov (United States)

    DU, Tong; Niu, Hongxin

    2014-09-01

    The aim of the present study was to establish an animal liver metastasis model with human colon cancer and investigate the inhibitory effect of the wild type (WT) p53 gene combined with thymidine kinase/ganciclovir (TK/GCV) and cytosine deaminase/5-fluorocytosine (CD/5-FC) systems on liver metastasis of colon cancer. A nude mouse liver metastasis model with human colon cancer was established via a spleen cultivation method. A total of 32 nude mice were randomly divided into four groups, each group with eight mice. Group 1 mice received splenic injections of SW480 cells (control group), while group 2 mice were injected with SW480/p53 cells in the spleen. Group 3 mice were administered splenic injections of SW480/TK-CD cells, and GCV and 5-FC were injected into the abdominal cavity. Finally, group 4 mice received splenic injections of SW480/p53 cells mixed in equal proportion with SW480/TK-CD cells, as well as GCV and 5-FC injections in the abdominal cavity. These cells described were constructed in our laboratory and other laboratories. The number of liver metastatic tumors, the liver metastasis rate, conventional pathology, electron microscopy and other indicators in the nude mice of each group were compared and observed. The nude mouse liver metastasis model with human colon cancer was successfully established; the liver metastasis rate of the control group was 100%. The results demonstrated that the rate of liver metastasis in the nude mice in each treatment group decreased, as well as the average number of liver metastatic tumors. Furthermore, the effect of the treatment group with genetic combination (group 4) was the most effective, demonstrating that WTp53 had a synergistic effect with TK/GCV and CD/5-FC. Therefore, the present study successfully established a mouse model of liver metastasis with colon cancer by injecting human colon cancer cells in the spleen. Combined gene therapy was shown to have a synergistic effect, which effectively inhibited the

  1. A Robust Motion Artifact Detection Algorithm for Accurate Detection of Heart Rates From Photoplethysmographic Signals Using Time-Frequency Spectral Features.

    Science.gov (United States)

    Dao, Duy; Salehizadeh, S M A; Noh, Yeonsik; Chong, Jo Woon; Cho, Chae Ho; McManus, Dave; Darling, Chad E; Mendelson, Yitzhak; Chon, Ki H

    2017-09-01

    Motion and noise artifacts (MNAs) impose limits on the usability of the photoplethysmogram (PPG), particularly in the context of ambulatory monitoring. MNAs can distort PPG, causing erroneous estimation of physiological parameters such as heart rate (HR) and arterial oxygen saturation (SpO2). In this study, we present a novel approach, "TifMA," based on using the time-frequency spectrum of PPG to first detect the MNA-corrupted data and next discard the nonusable part of the corrupted data. The term "nonusable" refers to segments of PPG data from which the HR signal cannot be recovered accurately. Two sequential classification procedures were included in the TifMA algorithm. The first classifier distinguishes between MNA-corrupted and MNA-free PPG data. Once a segment of data is deemed MNA-corrupted, the next classifier determines whether the HR can be recovered from the corrupted segment or not. A support vector machine (SVM) classifier was used to build a decision boundary for the first classification task using data segments from a training dataset. Features from time-frequency spectra of PPG were extracted to build the detection model. Five datasets were considered for evaluating TifMA performance: (1) and (2) were laboratory-controlled PPG recordings from forehead and finger pulse oximeter sensors with subjects making random movements, (3) and (4) were actual patient PPG recordings from UMass Memorial Medical Center with random free movements and (5) was a laboratory-controlled PPG recording dataset measured at the forehead while the subjects ran on a treadmill. The first dataset was used to analyze the noise sensitivity of the algorithm. Datasets 2-4 were used to evaluate the MNA detection phase of the algorithm. The results from the first phase of the algorithm (MNA detection) were compared to results from three existing MNA detection algorithms: the Hjorth, kurtosis-Shannon entropy, and time-domain variability-SVM approaches. This last is an approach

  2. The Performance of Short-Term Heart Rate Variability in the Detection of Congestive Heart Failure

    Directory of Open Access Journals (Sweden)

    Fausto Lucena

    2016-01-01

    Full Text Available Congestive heart failure (CHF is a cardiac disease associated with the decreasing capacity of the cardiac output. It has been shown that the CHF is the main cause of the cardiac death around the world. Some works proposed to discriminate CHF subjects from healthy subjects using either electrocardiogram (ECG or heart rate variability (HRV from long-term recordings. In this work, we propose an alternative framework to discriminate CHF from healthy subjects by using HRV short-term intervals based on 256 RR continuous samples. Our framework uses a matching pursuit algorithm based on Gabor functions. From the selected Gabor functions, we derived a set of features that are inputted into a hybrid framework which uses a genetic algorithm and k-nearest neighbour classifier to select a subset of features that has the best classification performance. The performance of the framework is analyzed using both Fantasia and CHF database from Physionet archives which are, respectively, composed of 40 healthy volunteers and 29 subjects. From a set of nonstandard 16 features, the proposed framework reaches an overall accuracy of 100% with five features. Our results suggest that the application of hybrid frameworks whose classifier algorithms are based on genetic algorithms has outperformed well-known classifier methods.

  3. A Robust Dynamic Heart-Rate Detection Algorithm Framework During Intense Physical Activities Using Photoplethysmographic Signals

    Directory of Open Access Journals (Sweden)

    Jiajia Song

    2017-10-01

    Full Text Available Dynamic accurate heart-rate (HR estimation using a photoplethysmogram (PPG during intense physical activities is always challenging due to corruption by motion artifacts (MAs. It is difficult to reconstruct a clean signal and extract HR from contaminated PPG. This paper proposes a robust HR-estimation algorithm framework that uses one-channel PPG and tri-axis acceleration data to reconstruct the PPG and calculate the HR based on features of the PPG and spectral analysis. Firstly, the signal is judged by the presence of MAs. Then, the spectral peaks corresponding to acceleration data are filtered from the periodogram of the PPG when MAs exist. Different signal-processing methods are applied based on the amount of remaining PPG spectral peaks. The main MA-removal algorithm (NFEEMD includes the repeated single-notch filter and ensemble empirical mode decomposition. Finally, HR calibration is designed to ensure the accuracy of HR tracking. The NFEEMD algorithm was performed on the 23 datasets from the 2015 IEEE Signal Processing Cup Database. The average estimation errors were 1.12 BPM (12 training datasets, 2.63 BPM (10 testing datasets and 1.87 BPM (all 23 datasets, respectively. The Pearson correlation was 0.992. The experiment results illustrate that the proposed algorithm is not only suitable for HR estimation during continuous activities, like slow running (13 training datasets, but also for intense physical activities with acceleration, like arm exercise (10 testing datasets.

  4. A Low-Power Wireless Image Sensor Node with Noise-Robust Moving Object Detection and a Region-of-Interest Based Rate Controller

    Science.gov (United States)

    2017-03-01

    from both environment and hardware further reduces the transmission energy with negligible computation and memory overhead. The rate controller...detection, Region-of-interest, Rate control Introduction In wireless image sensor nodes for moving object surveillance, energy efficiency can be...noise, reliable moving object detection is required to avoid unnecessary transmission of background scenes [1]. Transmission energy can be further

  5. Multiparameter FLAER-based flow cytometry for screening of paroxysmal nocturnal hemoglobinuria enhances detection rates in patients with aplastic anemia.

    Science.gov (United States)

    Sachdeva, Man Updesh Singh; Varma, Neelam; Chandra, Dinesh; Bose, Parveen; Malhotra, Pankaj; Varma, Subhash

    2015-05-01

    Flow cytometry is the gold standard methodology for screening of paroxysmal nocturnal hemoglobinuria. In the last few years, proaerolysin conjugated with fluorescein (FLAER) has become an important component of antibody panel used for the detection of paroxysmal nocturnal hemoglobinuria (PNH) clone. This study aimed to compare PNH clone detection by flow cytometry in the pre-FLAER era versus the FLAER era. This was a retrospective analysis of 4 years and included 1004 individuals screened for PNH clone, either presenting as hemolytic anemia or as aplastic anemia. In the pre-FLAER time period, the RBCs and neutrophils were screened with antibodies against CD55 and CD59. With the introduction of FLAER, neutrophils were screened with FLAER/CD24/CD15 and monocytes with FLAER/CD14/CD33 combination. A comparative analysis was done for detection of PNH clone in aplastic anemia patients versus non-aplastic anemia patients, as well as between pre-FLAER and FLAER era. Out of a total of 1004 individuals, 59 (5.8%) were detected to have PNH clone positivity. The frequency of PNH clone detected in aplastic anemia and non-aplastic anemia groups was 12.02 and 3.36%, respectively. The detection rate of PNH clone increased from 4.5% (32/711) in the pre-FLAER era to 9.2% (27/293) with the introduction of FLAER. However, this increase could be attributed to increased detection of PNH clone in the aplastic anemia group, which showed a significant increase from 8.3 to 18.2% after use of FLAER. In the non-aplastic group, PNH clone was detected with similar frequencies before and after use of FLAER (3.2 versus 3.8%, respectively). Mean PNH clone size was lower in the aplastic anemia group when compared with the non-aplastic group. RBCs always showed a lower clone size than neutrophils. PNH clone on neutrophils and monocytes was however similar. Inclusion of FLAER increases the sensitivity of the test which is especially useful in picking up small PNH clones in patients of aplastic anemia.

  6. [A Distal Bile Duct Carcinoma Patient Who Underwent Surgical Resection for Liver Metastasis].

    Science.gov (United States)

    Komiyama, Sosuke; Izumiya, Yasuhito; Kimura, Yu; Nakashima, Shingo; Kin, Syuichi; Kawakami, Sadao

    2018-03-01

    A 70-year-old man with distal bile duct carcinoma underwent a subtotal stomach-preserving pancreaticoduodenectomy without adjuvant chemotherapy. One and a half years after the surgery, elevated levels of serum SPan-1(38.1 U/mL)were observed and CT scans demonstrated a solitary metastasis, 25mm in size, in segment 8 of the liver. The patient received 2 courses of gemcitabine-cisplatin combination chemotherapy. No new lesions were detected after chemotherapy and the patient underwent a partial liver resection of segment 8. The pathological examination revealed a metachronous distant metastasis originating from the bile duct carcinoma. Subsequently, the patient received S-1 adjuvant chemotherapy for 6 months. Following completion of all therapies, the patient survived without tumor recurrence for 3 years and 10 months after the initial operation. Thus, surgical interventions might be effective in improving prognosis among selected patients with postoperative liver metastasis of bile duct carcinoma.

  7. A study of skeletal metastasis of carcinoma of the uterine cervix

    International Nuclear Information System (INIS)

    Tanouchi, Miki; Sui, Osamu; Kashihara, Kenichi

    1990-01-01

    Between January 1980 and December 1988, 373 patients with carcinoma of the uterine cervix were treated at the Department of Radiology, Tokushima University Hospital. Of the 373 patients, 229 were treated by radiotherapy alone, and 144 were treated by post-operative radiotherapy. The incidence of skeletal metastasis was 6.4%, 24 patients out of 373. Ten of these patients were treated with radiotherapy alone, and 14 with radical surgery and radiotherapy. Nineteen patients belonged in the early clinical stage (stage Ia through stage IIb). Lesions of skeletal metastases were usually detected within 2 years after the initial treatment, and the most common site of skeletal metastasis was the pelvic bone, followed by the lumbar spine. Most patients with skeletal metastases were treated by radiotherapy, chemotherapy, and combined radio- and chemotherapy. Severe pain due to skeletal metastasis was relieved by radiotherapy and combined therapy, but no method of treatment could extend the prognosis. (author)

  8. Appendicitis complicated by appendiceal metastasis via peritoneal dissemination from lung cancer.

    Science.gov (United States)

    Shiota, Naoki; Furonaka, Makoto; Kikutani, Kazuya; Haji, Keiko; Fujisaki, Seiji; Nishida, Toshihiro

    2016-07-01

    Peritoneal disseminations from lung cancer are difficult to detect during the patient's clinical course. Therefore, complications of this condition are unclear. We report a case in which peritoneal dissemination from lung cancer complicated appendicitis. A 74-year-old man with lung cancer who was receiving maintenance therapy presented at our hospital because of abdominal pain. It was the seventh day after the 14th cycle of maintenance therapy with bevacizumab. He was diagnosed with acute appendicitis. The resected appendix showed acute appendicitis complicated by appendiceal metastasis from lung cancer. Adenocarcinoma was observed predominantly in the serous membrane from the neck to the tail of the appendix. The distribution of the adenocarcinoma was diffuse. Peritoneal dissemination was considered the route of metastasis. He was admitted to the palliative care unit 10 months after appendectomy. Appendiceal metastasis via peritoneal dissemination from lung cancer complicated appendicitis in our patient who had been receiving bevacizumab.

  9. Metastasis to the penis in a patient with adenocarcinoma of lung, case report and literature review.

    Science.gov (United States)

    Zheng, Fu-Fu; Zhang, Zhong-Yun; Dai, Yu-Ping; Liang, Yue-You; Deng, Chun-Hua; Tao, Yu

    2009-01-01

    Metastasis of lung cancer to the penis is very rare; it causes various clinical symptoms seriously affecting the quality of life. Early recognition and appropriate management will likely enhance survival in these patients. Here, we report a case of penile metastasis secondary to pulmonary carcinoma along with a review of the literature. One case of penile metastasis secondary to pulmonary carcinoma was detected in a 51-year-old patient who was admitted to the First Affiliated Hospital of Sun Yat-Sen University with persistent cough along with swelling of the perineum and penis. The clinical features, diagnosis, and treatment of this disease along with a relevant literature are reviewed and discussed. A MEDLINE search was performed to identify similar reports in the literature. CT scan revealed lung mass, and a glans penis ulcer and enlargement of inguinal lymph nodes was discovered upon physical examination. CT-guided percutaneous puncture of the lung mass revealed adenocarcinoma of lung, and biopsies of the glans penis ulcer and inguinal lymph nodes confirmed metastatic adenocarcinoma. The patients received chemotherapy and died of acute pulmonary embolism in less than 2 months. Metastasis of lung cancer to the penis is extremely rare. It presents an advanced form of lung cancer, and thus survival is extremely short. Although treatment of penile metastasis is almost always palliative, early recognition may enhance survival for these patients.

  10. [Surgical managment of colorectal liver metastasis].

    Science.gov (United States)

    Prot, Thomas; Halkic, Nermin; Demartines, Nicolas

    2007-06-27

    Surgery offer the only curative treatment for colorectal hepatic metastasis. Nowadays, five-year survival increases up to 58% in selected cases, due to the improvement and combination of chemotherapy, surgery and ablative treatment like embolisation, radio-frequency or cryoablation. Surgery should be integrated in a multi disciplinary approach and initial work-up must take in account patient general conditions, tumor location, and possible extra hepatic extension. Thus, a surgical resection may be performed immediately or after preparation with chemotherapy or selective portal embolization. Management of liver metastasis should be carried out in oncological hepato-biliary centre.

  11. The role of exosomes in cancer metastasis.

    Science.gov (United States)

    Steinbichler, Teresa Bernadette; Dudás, József; Riechelmann, Herbert; Skvortsova, Ira-Ida

    2017-06-01

    Exosomes are small membrane vesicles with a size ranging from 40 to 100nm. They can serve as functional mediators in cell interaction leading to cancer metastasis. Metastasis is a complex multistep process of cancer cell invasion, survival in blood vessels, attachment to and colonization of the host organ. Exosomes influence every step of this cascade and can be targeted by oncological treatment. This review highlights the role of exosomes in the various steps of the metastatic cascade and how exosome dependent pathways can be targeted as therapeutic approach or used for liquid biopsies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. The Multiple Roles of Exosomes in Metastasis

    Science.gov (United States)

    WEIDLE, H. ULRICH; BIRZELE, FABIAN; KOLLMORGEN, GWEN; RÜGER, RÜDIGER

    2016-01-01

    Exosomes are important contributors to cell−cell communication and their role as diagnostic markers for cancer and the pathogenesis for cancer is under intensive investigation. Here, we focus on their role in metastasis-related processes. We discuss their impact regarding promotion of invasion and migration of tumor cells, conditioning of lymph nodes, generation of premetastatic niches and organotropism of metastasis. Furthermore, we highlight interactions of exosomes with bone marrow and stromal components such as fibroblasts, endothelial cells, myeloid- and other immune-related cells in the context of metastases. For all processes as described above, we outline molecular and cellular components for therapeutic intervention with metastatic processes. PMID:28031234

  13. Renal cell carcinoma presenting as mandibular metastasis

    Directory of Open Access Journals (Sweden)

    Hassan Ahmadnia

    2013-01-01

    Full Text Available Renal clear cell carcinoma (RCC has different manifestations, including uncommon metastasis and paraneoplastic syndromes. Here we report a rare case of RCC presenting as metastasis to the mandible. A 57-year-old patient with mandibular swelling was referred to the dentist. After necessary evaluations, an incisional biopsy of mandible showed metastatic RCC. The patient was referred to the urologist. The patient underwent right radical nephrectomy. Pathological examination showed clear renal cell carcinoma. Every abnormal bone lesion in the oral cavity should be evaluated carefully and the possibility of a malignant lesion should always be considered.

  14. Duodenal Metastasis of Malignant Pleural Mesothelioma

    Directory of Open Access Journals (Sweden)

    Huang-Chi Chen

    2008-12-01

    Full Text Available Metastatic malignant mesothelioma of the pleura is uncommon at the time of initial diagnosis. The gastrointestinal lumen is rarely found at autopsy in patients with widespread disease. Here, we describe an extremely rare case of isolated duodenal metastasis of sarcomatoid mesothelioma of the pleura in a 73-year-old man, without memory of any direct exposure to asbestos. The possibility of gastrointestinal tract metastasis should be considered in the presence of anemia or positive occult blood test in patients with malignant pleural mesothelioma.

  15. Effects of episodic sediment supply on bedload transport rate in mountain rivers. Detecting debris flow activity using continuous monitoring

    Science.gov (United States)

    Uchida, Taro; Sakurai, Wataru; Iuchi, Takuma; Izumiyama, Hiroaki; Borgatti, Lisa; Marcato, Gianluca; Pasuto, Alessandro

    2018-04-01

    Monitoring of sediment transport from hillslopes to channel networks as a consequence of floods with suspended and bedload transport, hyperconcentrated flows, debris and mud flows is essential not only for scientific issues, but also for prevention and mitigation of natural disasters, i.e. for hazard assessment, land use planning and design of torrent control interventions. In steep, potentially unstable terrains, ground-based continuous monitoring of hillslope and hydrological processes is still highly localized and expensive, especially in terms of manpower. In recent years, new seismic and acoustic methods have been developed for continuous bedload monitoring in mountain rivers. Since downstream bedload transport rate is controlled by upstream sediment supply from tributary channels and bed-external sources, continuous bedload monitoring might be an effective tool for detecting the sediments mobilized by debris flow processes in the upper catchment and thus represent an indirect method to monitor slope instability processes at the catchment scale. However, there is poor information about the effects of episodic sediment supply from upstream bed-external sources on downstream bedload transport rate at a single flood time scale. We have examined the effects of sediment supply due to upstream debris flow events on downstream bedload transport rate along the Yotagiri River, central Japan. To do this, we have conducted continuous bedload observations using a hydrophone (Japanese pipe microphone) located 6.4 km downstream the lower end of a tributary affected by debris flows. Two debris flows occurred during the two-years-long observation period. As expected, bedload transport rate for a given flow depth showed to be larger after storms triggering debris flows. That is, although the magnitude of sediment supply from debris flows is not large, their effect on bedload is propagating >6 km downstream at a single flood time scale. This indicates that continuous bedload

  16. Analysis of variables affecting unemployment rate and detecting for cluster in West Java, Central Java, and East Java in 2012

    Science.gov (United States)

    Samuel, Putra A.; Widyaningsih, Yekti; Lestari, Dian

    2016-02-01

    The objective of this study is modeling the Unemployment Rate (UR) in West Java, Central Java, and East Java, with rate of disease, infant mortality rate, educational level, population size, proportion of married people, and GDRP as the explanatory variables. Spatial factors are also considered in the modeling since the closer the distance, the higher the correlation. This study uses the secondary data from BPS (Badan Pusat Statistik). The data will be analyzed using Moran I test, to obtain the information about spatial dependence, and using Spatial Autoregressive modeling to obtain the information, which variables are significant affecting UR and how great the influence of the spatial factors. The result is, variables proportion of married people, rate of disease, and population size are related significantly to UR. In all three regions, the Hotspot of unemployed will also be detected districts/cities using Spatial Scan Statistics Method. The results are 22 districts/cities as a regional group with the highest unemployed (Most likely cluster) in the study area; 2 districts/cities as a regional group with the highest unemployed in West Java; 1 district/city as a regional groups with the highest unemployed in Central Java; 15 districts/cities as a regional group with the highest unemployed in East Java.

  17. Prospective assessment of the false positive rate of the Australian snake venom detection kit in healthy human samples.

    Science.gov (United States)

    Nimorakiotakis, Vasilios Bill; Winkel, Kenneth D

    2016-03-01

    The Snake Venom Detection Kit (SVDK; bioCSL Pty Ltd, Australia) distinguishes venom from the five most medically significant snake immunotypes found in Australia. This study assesses the rate of false positives that, by definition, refers to a positive assay finding in a sample from someone who has not been bitten by a venomous snake. Control unbroken skin swabs, simulated bite swabs and urine specimens were collected from 61 healthy adult volunteers [33 males and 28 females] for assessment. In all controls, simulated bite site and urine samples [a total of 183 tests], the positive control well reacted strongly within one minute and no test wells reacted during the ten minute incubation period. However, in two urine tests, the negative control well gave a positive reaction (indicating an uninterpretable test). A 95% confidence interval for the false positive rate, on a per-patient rate, derived from the findings of this study, would extend from 0% to 6% and, on a per-test basis, it would be 0-2%. It appears to be a very low incidence (0-6%) of intrinsic true false positives for the SVDK. The clinical impresssion of a high SVDK false positive rate may be mostly related to operator error. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  18. Can concurrent core biopsy and fine needle aspiration biopsy improve the false negative rate of sonographically detectable breast lesions?

    Directory of Open Access Journals (Sweden)

    Chang Tsai-Wang

    2010-07-01

    Full Text Available Abstract Background The aims of this study were to determine the accuracy of concurrent core needle biopsy (CNB and fine needle aspiration biopsy (FNAB for breast lesions and to estimate the false-negative rate using the two methods combined. Methods Over a seven-year period, 2053 patients with sonographically detectable breast lesions underwent concurrent ultrasound-guided CNB and FNAB. The sonographic and histopathological findings were classified into four categories: benign, indeterminate, suspicious, and malignant. The histopathological findings were compared with the definitive excision pathology results. Patients with benign core biopsies underwent a detailed review to determine the false-negative rate. The correlations between the ultrasonography, FNAB, and CNB were determined. Results Eight hundred eighty patients were diagnosed with malignant disease, and of these, 23 (2.5% diagnoses were found to be false-negative after core biopsy. After an intensive review of discordant FNAB results, the final false-negative rate was reduced to 1.1% (p-value = 0.025. The kappa coefficients for correlations between methods were 0.304 (p-value p-value p-value Conclusions Concurrent CNB and FNAB under ultrasound guidance can provide accurate preoperative diagnosis of breast lesions and provide important information for appropriate treatment. Identification of discordant results using careful radiological-histopathological correlation can reduce the false-negative rate.

  19. Impact of changing from staining to culture techniques on detection rates of Campylobacter spp. in routine stool samples in Chile.

    Science.gov (United States)

    Porte, Lorena; Varela, Carmen; Haecker, Thomas; Morales, Sara; Weitzel, Thomas

    2016-05-13

    Campylobacter is a leading cause of bacterial gastroenteritis, but sensitive diagnostic methods such as culture are expensive and often not available in resource limited settings. Therefore, direct staining techniques have been developed as a practical and economical alternative. We analyzed the impact of replacing Campylobacter staining with culture for routine stool examinations in a private hospital in Chile. From January to April 2014, a total of 750 consecutive stool samples were examined in parallel by Hucker stain and Campylobacter culture. Isolation rates of Campylobacter were determined and the performance of staining was evaluated against culture as the gold standard. Besides, isolation rates of Campylobacter and other enteric pathogens were compared to those of past years. Campylobacter was isolated by culture in 46 of 750 (6.1 %) stool samples. Direct staining only identified three samples as Campylobacter positive and reached sensitivity and specificity values of 6.5 and 100 %, respectively. In comparison to staining-based detection rates of previous years, we observed a significant increase of Campylobacter cases in our patients. Direct staining technique for Campylobacter had a very low sensitivity compared to culture. Staining methods might lead to a high rate of false negative results and an underestimation of the importance of campylobacteriosis. With the inclusion of Campylobacter culture, this pathogen became a leading cause of intestinal infection in our patient population.

  20. Significant Overexpression of DVL1 in Taiwanese Colorectal Cancer Patients with Liver Metastasis

    Directory of Open Access Journals (Sweden)

    Shiu-Ru Lin

    2013-10-01

    Full Text Available Undetected micrometastasis plays a key role in the metastasis of cancer in colorectal cancer (CRC patients. The aim of this study is to identify a biomarker of CRC patients with liver metastasis through the detection of circulating tumor cells (CTCs. Microarray and bioinformatics analysis of 10 CRC cancer tissue specimens compared with normal adjacent tissues revealed that 31 genes were up-regulated (gene expression ratio of cancer tissue to paired normal tissue > 2 in the cancer patients. We used a weighted enzymatic chip array (WEnCA including 31 prognosis-related genes to investigate CTCs in 214 postoperative stage I–III CRC patients and to analyze the correlation between gene expression and clinico-pathological parameters. We employed the immunohistochemistry (IHC method with polyclonal mouse antibody against DVL1 to detect DVL1 expression in 60 CRC patients. CRC liver metastasis occurred in 19.16% (41/214 of the patients. Using univariate analysis and multivariate proportional hazards regression analysis, we found that DVL1 mRNA overexpression had a significant, independent predictive value for liver metastasis in CRC patients (OR: 5.764; 95% CI: 2.588–12.837; p < 0.0001 on univariate analysis; OR: 3.768; 95% CI: 1.469–9.665; p = 0.006 on multivariate analysis. IHC staining of the immunoreactivity of DVL1 showed that DVL1 was localized in the cytoplasm of CRC cells. High expression of DVL1 was observed in 55% (33/60 of CRC tumor specimens and was associated significantly with tumor depth, perineural invasion and liver metastasis status (all p < 0.05. Our experimental results demonstrated that DVL1 is significantly overexpressed in CRC patients with liver metastasis, leading us to conclude that DVL1 could be a potential prognostic and predictive marker for CRC patients.

  1. Study on 41Ca-AMS for diagnosis and assessment of cancer bone metastasis in rats

    International Nuclear Information System (INIS)

    Shen, Hongtao; Pang, Fangfang; Jiang, Shan; He, Ming; Dong, Kejun; Dou, Liang; Pang, Yijun; Yang, Xianlin; Ruan, Xiangdong; Liu, Manjun; Xia, Chunbo

    2015-01-01

    The annual incidence of new cancer patients in China is about 2 million, 30–40% of which will end up with bone metastasis. Profound study on the preclinical model and early diagnosis of cancer bone metastasis in rats are very significant for the drug development, better understanding and treatment of bone metastases. In order to monitor the process of bone metabolism and early detection of bone metastasis of cancer cells, a technique of 41 Ca isotope tracer combined with AMS has been developed and applied in the study on the bone metastasis of cancer cells by rat model. In this work, 3-month-old female Sprague–Dawley (SD) rats were randomly divided into different groups, and tumor cells injected respectively into the tail vein, femoral artery, femoral cavity and the thigh muscle to establish the rat models for bone metastases. The most appropriate model, i.e., the thigh muscle group, was finally adopted in our real metastases experiment. Each rat in this group was intramuscularly (i.m.) injected with 250 μl CaCl 2 solution (containing 1.4 mg Ca and 5nCi 41 Ca). About 40 days later, the rat mammary gland carcinoma cells (Walker 256) were injected into these rats following the established protocol. After bone metastasis, medicine interventions were performed. The sequential urine and blood samples were collected and analyzed for 41 Ca (by AMS) and N-terminal telopeptide (Ntx), respectively. Bone Mineral Density (BMD) values in the femur and the tibia were measured by CT scan. The results of 41 Ca/Ca in longitudinal urinary samples can sensitively reveal the skeletal perturbations caused by bone metastasis of rats, suggests that 41 Ca might be similarly developed for human use and improve clinical management through the assessment of the curative effect and non-invasive detection of the earliest stages of cancer growth in bone.

  2. Inhibition of Breast Cancer Metastasis by Heregulin-Beta 1

    National Research Council Canada - National Science Library

    Yu, Dihua

    1999-01-01

    The major goal of this Idea proposal is to determine whether and how HRG-Beta1 inhibits breast cancer metastasis and to identify the functional domains that are sufficient for inhibition of breast cancer metastasis...

  3. Spontaneous rupture of adrenal metastasis from hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Chae Hun; Kim, Hyun Jin; Park, Soo Youn; Hwang, Seong Su; Choi, Hyun Joo [St. Vincent Hospital, Suwon (Korea, Republic of)

    2007-03-15

    Rupture of adrenal tumor from various primary origins is a rather rare event. We report here on a ruptured adrenal metastasis from hepatocellular carcinoma, and this ruptured metastasis was observed at the time of the initial diagnosis.

  4. Invasive cancer cells and metastasis

    Science.gov (United States)

    Mierke, Claudia Tanja

    2013-12-01

    The physics of cancer is a relatively new emerging field of cancer research. In the last decade it has become a focus of biophysical research as well as becoming a novel focus for classical cancer research. This special section of Physical Biology focusing on invasive cancer cells and metastasis (physical oncology) will give greater insight into the different subfields where physical approaches are being applied to cancer research. This focus on the physical aspects of cancer is necessary because novel approaches in the field of genomics and proteomics have not altered the field of cancer research dramatically, due to the fact that few breakthroughs have been made. It is still not understood why some primary tumors metastasize and thus have a worse outcome compared to others that do not metastasize. As biophysicists, we and others suggest that the mechanical properties of the cancer cells, which possess the ability to transmigrate, are quite different compared to non-metastatic and non-invasive cancer cells. Furthermore, we hypothesize that these cancer cells undergo a selection process within the primary tumor that enables them to weaken their cell-cell adhesions and to alter their cell-matrix adhesions in order to be able to cross the outermost boundary of the primary tumor, as well as the surrounding basement membrane, and to invade the connective tissue. This prerequisite may also help the cancer cells to enter blood or lymph vessels, get transported with the vessel flow and form secondary tumors either within the vessel, directly on the endothelium, or in a different organ after crossing the endothelial lining a second time. This special section begins with a paper by Mark F Coughlin and Jeffrey J Fredberg on the changes in cytoskeletal dynamics and nonlinear rheology due to the metastatic capability of cancer cells from different cancer tissue types such as skin, bladder, prostate and kidney [1]. The hypothesis was that the metastatic outcome is impacted by

  5. Endobronchial metastasis: CT findings and its usefulness in bronchoscopic correlation

    International Nuclear Information System (INIS)

    Ko, Ji Ho; Jung, Gyoo Sik; Kim, Seong Min; Huh Jin Do; Joh, Young Duk; Jang, Tae Weon

    2000-01-01

    To evaluate the CT findings of bronchial abnormalities in patients with endobronchial metastasis from extrapulmonary tumors, and to correlate these with the bronchoscopic findings. The authors retrospectively reviewed the CT and bronchoscopic findings of 17 patients (M:F =3D 9:8; mean age, 56 years) with histologically proven endobronchial metastasis from extrapulmonary primary tumors. Carcinoma of the uterine cervix (n=3D5) was the most common primary site for endobronchial metastasis. CT findings of bronchial abnormalities with associated peribronchial and lung parenchymal lesions were analyzed and compared with the bronchoscopic findings. Among the 17 patients, 20 sites of bronchial abnormalities were visualized bronchoscopically. CT findings of bronchial abnormalities were smooth narrowing (n=3D11), occlusion (n=3D3), intraluminal mass (n=3D4), and normal (n=3D2). Peribronchial lesions (lymph node enlargement or parenchymal mass) were found in 12 cases. Bronchoscopy revealed bronchial narrowing due to a mucosal nodule or intraluminal polypoid mass in 16 cases, and total obstruction of the bronchus in four. With regard to the identification of bronchial abnormalities, the findings of CT and of bronchoscopy agreed in 17 cases and disagreed in three. While bronchoscopy was advantageous for detecting early mucosal abnormality, CT effectively evaluated the extent of a lesion beyond the stenosis or bronchial obstruction. CT was also useful for predicting the causes of bronchial abnormalities. CT is relatively accurate in evaluating bronchial abnormalities, and in patients with endobronchial metastases may be used as a complementary procedure to bronchoscopy for evaluating the extent of the lesion. (author)

  6. Measurement of radiocesium concentration in trees using cumulative gamma radiation dose rate detection systems - A simple presumption for radiocesium concentration in living woods using glass-badge based gamma radiation dose rate detection system

    Energy Technology Data Exchange (ETDEWEB)

    Yoshihara, T.; Hashida, S.N. [Plant Molecular Biology, Laboratory of Environmental Science, Central Research Institute of Electric Power Industry (CRIEPI), 1646 Abiko, Chiba 270-1194 (Japan); Kawachi, N.; Suzui, N.; Yin, Y.G.; Fujimaki, S. [Radiotracer Imaging Gr., Quantum Beam Science Center, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Nagao, Y.; Yamaguchi, M. [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-07-01

    Radiocesium from the severe accident at the Fukushima Dai-ichi Nuclear Power Plant on 11 March 2011 contaminates large areas. After this, a doubt for forest products, especially of mushroom, is indelible at the areas. Pruned woody parts and litters are containing a considerable amount of radiocesium, and generates a problem at incineration and composting. These mean that more attentive survey for each subject is expected; however, the present survey system is highly laborious/expensive and/or non-effective for this purpose. On the other hand, we can see a glass-badge based gamma radiation dose rate detection system. This system always utilized to detect a personal cumulative radiation dose, and thus, it is not suitable to separate a radiation from a specific object. However, if we can separate a radiation from a specific object and relate it with the own radiocesium concentration, it would enable us to presume the specific concentration with just an easy monitoring but without a destruction of the target nature and a complicated process including sampling, pre-treatment, and detection. Here, we present the concept of the measurement and results of the trials. First, we set glass-badges (type FS, Chiyoda Technol Corp., Japan) on a part of bough (approximately 10 cm in diameter) of Japanese flowering cherry trees (Prunus x yedoensis cv. Somei-Yoshino) with four different settings: A, a direct setting without any shield; B, a setting with an aluminum shield between bough and the glass-badge; C, a setting with a lead shield between bough and the glass-badge; D, a setting with a lead shield covering the glass-badge to shut the radiation from the surrounding but from bough. The deduction between the amount of each setting should separate a specific radiation of the bough from unlimited radiation from the surrounding. Even if the hourly dose rate is not enough to count the difference, a moderate cumulative dose would clear the difference. In fact, results demonstrated a

  7. Utility of preoperative ferumoxtran-10 MRI to evaluate retroperitoneal lymph node metastasis in advanced cervical cancer: Results of ACRIN 6671/GOG 0233

    Directory of Open Access Journals (Sweden)

    Mostafa Atri

    2015-01-01

    Conclusion: Addition of f-10 increased MRI sensitivity to detect LN metastasis in advanced cervical cancer. Increased sensitivity did not reach statistical significance and was at the expense of lower specificity.

  8. Metastasis in renal cell carcinoma: Biology and implications for therapy

    Directory of Open Access Journals (Sweden)

    Jun Gong

    2016-10-01

    Full Text Available Although multiple advances have been made in systemic therapy for renal cell carcinoma (RCC, metastatic RCC remains incurable. In the current review, we focus on the underlying biology of RCC and plausible mechanisms of metastasis. We further outline evolving strategies to combat metastasis through adjuvant therapy. Finally, we discuss clinical patterns of metastasis in RCC and how distinct systemic therapy approaches may be considered based on the anatomic location of metastasis.

  9. Tiamulin inhibits breast cancer growth and pulmonary metastasis by decreasing the activity of CD73.

    Science.gov (United States)

    Yang, Xu; Pei, Shimin; Wang, Huanan; Jin, Yipeng; Yu, Fang; Zhou, Bin; Zhang, Hong; Zhang, Di; Lin, Degui

    2017-04-11

    Metastasis is the leading cause of death in breast cancer patients. CD73, also known as ecto-5'-nucleotidase, plays a critical role in cancer development including metastasis. The existing researches indicate that overexpression of CD73 promotes growth and metastasis of breast cancer. Therefore, CD73 inhibitor can offer a promising treatment for breast cancer. Here, we determined whether tiamulin, which was found to inhibit CD73, was able to suppress breast cancer development and explored the related mechanisms. We firstly measured the effect of tiamulin hydrogen fumarate (THF) on CD73 using high performance liquid chromatography (HPLC). Then, we investigated cell proliferation, migration and invasion in MDA-MB-231 human breast cancer cell line and 4 T1 mouse breast cancer cell line treated with THF by migration assay, invasion assay and activity assay. Besides, we examined the effect of THF on syngeneic mammary tumors of mice by immunohistochemistry. Our data demonstrated that THF inhibited CD73 by decreasing the activity instead of the expression of CD73. In vitro, THF inhibited the proliferation, migration and invasion of MDA-MB-231 and 4 T1 cells by suppressing CD73 activity. In vivo, animal experiments showed that THF treatment resulted in significant reduction in syngeneic tumor growth, microvascular density and lung metastasis rate. Our results indicate that THF inhibits growth and metastasis of breast cancer by blocking the activity of CD73, which may offer a promising treatment for breast cancer therapy.

  10. Mechanisms of Twist 1-Induced Invasion in Breast Cancer Metastasis

    Science.gov (United States)

    2011-01-01

    affect breast cancer metastasis with a subcutaneous mouse tumor implantation model of breast cancer metastasis. HMLE -Twist1 cells expressing shRNAs...13 4 Introduction Distant metastases are responsible for the vast majority of breast cancer deaths. This process...to migrate and invade is therefore essential to the metastatic process. The initial steps of breast cancer metastasis, local invasion and

  11. Computed tomography demonstration of a hypothalamic metastasis

    International Nuclear Information System (INIS)

    Chakeres, D.W.

    1983-01-01

    This case report describes a patient who presented with panhypopituitarism secondary to hypothalamic metastasis. A primary hypothalamic abnormality was suggested by computed tomographic (CT) demonstration of a small enhancing circular mass centered within the hypothalamus. Sellar radiographs and cerebral angiography were normal. (orig.)

  12. Computed tomography demonstration of a hypothalamic metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Chakeres, D.W.

    1983-05-01

    This case report describes a patient who presented with panhypopituitarism secondary to hypothalamic metastasis. A primary hypothalamic abnormality was suggested by computed tomographic (CT) demonstration of a small enhancing circular mass centered within the hypothalamus. Sellar radiographs and cerebral angiography were normal.

  13. Diagnosis and treatment of brain metastasis

    International Nuclear Information System (INIS)

    Sajama, Carlos; Lorenzoni, Jose; Tagle, Patricio

    2008-01-01

    Cerebral metastasis occur in 20 to 30 percent of patients with systemic cancer and are the most common type of intracranial tumor. The median survival of untreated patients is one month with a slightly longer survival in those treated with steroids. Patients treated with whole brain radiation therapy survive between 3 to 6 months. In selected cases survival can increase to 10 to 12 months with combination of surgery and radiotherapy or stereotactic radiosurgery alone or associated to radiotherapy. Most brain metastasis arise from lung, breast and melanomas. The most important criteria for selecting patients who will benefit from surgery or stereotactic radiosurgery are a Karnofsky score of 70 or more, systemic control of the cancer and absence of leptomeningeal involvement. Surgery is indicated in patients with a single lesion located in an accessible zone and stereotactic radiosurgery is indicated for lesions up to 3 cm of diameter, and in patients with up to 3 or 4 metastasis, no matter their location. The survival benefit of chemotherapy in brain metastasis has not been demonstrated

  14. A new protein Girdin in tumor metastasis

    Institute of Scientific and Technical Information of China (English)

    WANG Jing; FU Li; GU Feng; MA Yong-jie

    2010-01-01

    @@ The phosphatidylinositol 3-kinase/Akt serine/threonine kinase system regulates multiple cellular processes through the phosphorylation of a great number of downstream substrates and has been recognized as an important pathway for signal transduction, and in cancer invasion and metastasis.

  15. The protein C pathway in cancer metastasis

    NARCIS (Netherlands)

    Spek, C. Arnold; Arruda, Valder R.

    2012-01-01

    Cancer is frequently associated with activation of blood coagulation, which in turn has been suggested to promote tumor growth and metastasis. Indeed, low molecular weight heparin treatment significantly prolongs the survival of a wide variety of patients with cancer. Based on this notion that

  16. Diagnosis of bone metastasis from thyroid carcinoma

    DEFF Research Database (Denmark)

    Bechsgaard, Thor; Lelkaitis, Giedrius; Jensen, Karl E

    2015-01-01

    (MRI), but histology revealed a metastasis from thyroid carcinoma, although the patient had no previous history of thyroid malignancy and resection of the thyroid gland was without malignancy. Ultrasound-guided biopsy was possible due to cortical destruction and the multidisciplinary approach with re...

  17. Presumed choroidal metastasis of Merkel cell carcinoma

    International Nuclear Information System (INIS)

    Small, K.W.; Rosenwasser, G.O.; Alexander, E. III; Rossitch, G.; Dutton, J.J.

    1990-01-01

    Merkel cell carcinoma is a rare skin tumor of neural crest origin and is part of the amine precursor uptake and decarboxylase system. It typically occurs on the face of elderly people. Distant metastasis is almost uniformly fatal. Choroidal metastasis, to our knowledge, has not been described. We report a patient with Merkel cell carcinoma who had a synchronous solid choroidal tumor and a biopsy-proven brain metastasis. Our 56-year-old patient presented with a rapidly growing, violaceous preauricular skin tumor. Computed tomography of the head disclosed incidental brain and choroidal tumors. Light and electron microscopy of biopsy specimens of both the skin and the brain lesions showed Merkel cell carcinoma. Ophthalmoscopy, fluorescein angiography, and A and B echography revealed a solid choroidal mass. The brain and skin tumors responded well to irradiation. A radioactive episcleral plaque was applied subsequently to the choroidal tumor. All tumors regressed, and the patient was doing well 28 months later. To our knowledge this is the first case of presumed choroidal metastasis of Merkel cell carcinoma

  18. Status and prognosis of lymph node metastasis in patients with cardia cancer – A systematic review

    DEFF Research Database (Denmark)

    Okholm, Cecilie; Svendsen, Lars Bo; Achiam, Michael P

    2014-01-01

    BACKGROUND: Adenocarcinoma of the gastroesophageal junction (GEJ) has a poor prognosis and survival rates significantly decreases if lymph node metastasis is present. An extensive lymphadenectomy may increase chances of cure, but may also lead to further postoperative morbidity and mortality. The...

  19. Evaluating human cancer cell metastasis in zebrafish

    International Nuclear Information System (INIS)

    Teng, Yong; Xie, Xiayang; Walker, Steven; White, David T; Mumm, Jeff S; Cowell, John K

    2013-01-01

    In vivo metastasis assays have traditionally been performed in mice, but the process is inefficient and costly. However, since zebrafish do not develop an adaptive immune system until 14 days post-fertilization, human cancer cells can survive and metastasize when transplanted into zebrafish larvae. Despite isolated reports, there has been no systematic evaluation of the robustness of this system to date. Individual cell lines were stained with CM-Dil and injected into the perivitelline space of 2-day old zebrafish larvae. After 2-4 days fish were imaged using confocal microscopy and the number of metastatic cells was determined using Fiji software. To determine whether zebrafish can faithfully report metastatic potential in human cancer cells, we injected a series of cells with different metastatic potential into the perivitelline space of 2 day old embryos. Using cells from breast, prostate, colon and pancreas we demonstrated that the degree of cell metastasis in fish is proportional to their invasion potential in vitro. Highly metastatic cells such as MDA231, DU145, SW620 and ASPC-1 are seen in the vasculature and throughout the body of the fish after only 24–48 hours. Importantly, cells that are not invasive in vitro such as T47D, LNCaP and HT29 do not metastasize in fish. Inactivation of JAK1/2 in fibrosarcoma cells leads to loss of invasion in vitro and metastasis in vivo, and in zebrafish these cells show limited spread throughout the zebrafish body compared with the highly metastatic parental cells. Further, knockdown of WASF3 in DU145 cells which leads to loss of invasion in vitro and metastasis in vivo also results in suppression of metastasis in zebrafish. In a cancer progression model involving normal MCF10A breast epithelial cells, the degree of invasion/metastasis in vitro and in mice is mirrored in zebrafish. Using a modified version of Fiji software, it is possible to quantify individual metastatic cells in the transparent larvae to correlate with

  20. CT-guided percutaneous acetic acid injection therapy for liver metastasis

    International Nuclear Information System (INIS)

    Yu Tongfu; Wang Dehang; Zhuang Zhenwu; Li Linxun; Shi Haibin

    2002-01-01

    Objective: To evaluate the efficacy of CT-guided percutaneous acetic acid injection (PAI) for liver metastasis. Methods: Thirty-five cases (40 lesions) with liver metastasis were treated with PAI. 4-10 ml of 30% acetic acid with 1 ml contrast media was injected into every lesion. PAI was performed twice a week, and repeated for 2 to 3 weeks. Results: The tumors shrunk in 23 lesions, and remained unchanged in 12 lesions. The efficiency was 87.5%. All cases were followed up for 3 months to 3 years. One year survival rates was 62.9% (22 cases), 2 years 40.0% (14 cases), and 3 years 22.9% (8 cases). Conclusion: PAI was an effective therapy for liver metastasis

  1. Analysis of prognostic factors after resection of solitary liver metastasis in colorectal cancer: a 22-year bicentre study.

    Science.gov (United States)

    Acciuffi, Sara; Meyer, Frank; Bauschke, Astrid; Settmacher, Utz; Lippert, Hans; Croner, Roland; Altendorf-Hofmann, Annelore

    2018-03-01

    The investigation of the predictors of outcome after hepatic resection for solitary colorectal liver metastasis. We recruited 350 patients with solitary colorectal liver metastasis at the University Hospitals of Jena and Magdeburg, who underwent curative liver resection between 1993 and 2014. All patients had follow-up until death or till summer 2016. The follow-up data concern 96.6% of observed patients. The 5- and 10-year overall survival rates were 47 and 28%, respectively. The 5- and 10-year disease-free survival rates were 30 and 20%, respectively. The analysis of the prognostic factors revealed that the pT category of primary tumour, size and grade of the metastasis and extension of the liver resection had no statistically significant impact on survival and recurrence rates. In multivariate analysis, age, status of lymph node metastasis at the primary tumour, location of primary tumour, time of appearance of the metastasis, the use of preoperative chemotherapy and the presence of extrahepatic tumour proved to be independent statistically significant predictors for the prognosis. Moreover, patients with rectal cancer had a lower intrahepatic recurrence rate, but a higher extrahepatic recurrence rate. The long-term follow-up of patients with R0-resected liver metastasis is multifactorially influenced. Age and comorbidity have a role only in the overall survival. More than three lymph node metastasis reduced both the overall and disease-free survival. Extrahepatic tumour had a negative influence on the extrahepatic recurrence and on the overall survival. Neither overall survival nor recurrence rates was improved using neoadjuvant chemotherapy.

  2. Oligo- and Polymetastatic Progression in Lung Metastasis(es) Patients Is Associated with Specific MicroRNAs

    Science.gov (United States)

    Lussier, Yves A.; Ganai, Sabha; Khan, Sajid A.; Gnerlich, Jennifer; Darga, Thomas E.; Fan, Hanli; Karpenko, Oleksiy; Paty, Philip B.; Posner, Mitchell C.; Chmura, Steven J.; Hellman, Samuel; Ferguson, Mark K.; Weichselbaum, Ralph R.

    2012-01-01

    Rationale Strategies to stage and treat cancer rely on a presumption of either localized or widespread metastatic disease. An intermediate state of metastasis termed oligometastasis(es) characterized by limited progression has been proposed. Oligometastases are amenable to treatment by surgical resection or radiotherapy. Methods We analyzed microRNA expression patterns from lung metastasis samples of patients with ≤5 initial metastases resected with curative intent. Results Patients were stratified into subgroups based on their rate of metastatic progression. We prioritized microRNAs between patients with the highest and lowest rates of recurrence. We designated these as high rate of progression (HRP) and low rate of progression (LRP); the latter group included patients with no recurrences. The prioritized microRNAs distinguished HRP from LRP and were associated with rate of metastatic progression and survival in an independent validation dataset. Conclusion Oligo- and poly- metastasis are distinct entities at the clinical and molecular level. PMID:23251360

  3. Oligo- and polymetastatic progression in lung metastasis(es patients is associated with specific microRNAs.

    Directory of Open Access Journals (Sweden)

    Yves A Lussier

    Full Text Available RATIONALE: Strategies to stage and treat cancer rely on a presumption of either localized or widespread metastatic disease. An intermediate state of metastasis termed oligometastasis(es characterized by limited progression has been proposed. Oligometastases are amenable to treatment by surgical resection or radiotherapy. METHODS: We analyzed microRNA expression patterns from lung metastasis samples of patients with ≤ 5 initial metastases resected with curative intent. RESULTS: Patients were stratified into subgroups based on their rate of metastatic progression. We prioritized microRNAs between patients with the highest and lowest rates of recurrence. We designated these as high rate of progression (HRP and low rate of progression (LRP; the latter group included patients with no recurrences. The prioritized microRNAs distinguished HRP from LRP and were associated with rate of metastatic progression and survival in an independent validation dataset. CONCLUSION: Oligo- and poly- metastasis are distinct entities at the clinical and molecular level.

  4. Oligo- and polymetastatic progression in lung metastasis(es) patients is associated with specific microRNAs.

    Science.gov (United States)

    Lussier, Yves A; Khodarev, Nikolai N; Regan, Kelly; Corbin, Kimberly; Li, Haiquan; Ganai, Sabha; Khan, Sajid A; Gnerlich, Jennifer L; Gnerlich, Jennifer; Darga, Thomas E; Fan, Hanli; Karpenko, Oleksiy; Paty, Philip B; Posner, Mitchell C; Chmura, Steven J; Hellman, Samuel; Ferguson, Mark K; Weichselbaum, Ralph R

    2012-01-01

    Strategies to stage and treat cancer rely on a presumption of either localized or widespread metastatic disease. An intermediate state of metastasis termed oligometastasis(es) characterized by limited progression has been proposed. Oligometastases are amenable to treatment by surgical resection or radiotherapy. We analyzed microRNA expression patterns from lung metastasis samples of patients with ≤ 5 initial metastases resected with curative intent. Patients were stratified into subgroups based on their rate of metastatic progression. We prioritized microRNAs between patients with the highest and lowest rates of recurrence. We designated these as high rate of progression (HRP) and low rate of progression (LRP); the latter group included patients with no recurrences. The prioritized microRNAs distinguished HRP from LRP and were associated with rate of metastatic progression and survival in an independent validation dataset. Oligo- and poly- metastasis are distinct entities at the clinical and molecular level.

  5. Cerebral Metastasis from a Previously Undiagnosed Appendiceal Adenocarcinoma

    Directory of Open Access Journals (Sweden)

    Antonio Biroli

    2012-01-01

    Full Text Available Brain metastases arise in 10%–40% of all cancer patients. Up to one third of the patients do not have previous cancer history. We report a case of a 67-years-old male patient who presented with confusion, tremor, and apraxia. A brain MRI revealed an isolated right temporal lobe lesion. A thorax-abdomen-pelvis CT scan showed no primary lesion. The patient underwent a craniotomy with gross-total resection. Histopathology revealed an intestinal-type adenocarcinoma. A colonoscopy found no primary lesion, but a PET-CT scan showed elevated FDG uptake in the appendiceal nodule. A right hemicolectomy was performed, and the specimen showed a moderately differentiated mucinous appendiceal adenocarcinoma. Whole brain radiotherapy was administrated. A subsequent thorax-abdomen CT scan revealed multiple lung and hepatic metastasis. Seven months later, the patient died of disease progression. In cases of undiagnosed primary lesions, patients present in better general condition, but overall survival does not change. Eventual identification of the primary tumor does not affect survival. PET/CT might be a helpful tool in detecting lesions of the appendiceal region. To the best of our knowledge, such a case was never reported in the literature, and an appendiceal malignancy should be suspected in patients with brain metastasis from an undiagnosed primary tumor.

  6. Renal Metastasis from Primary Cervical Cancer: A Case Report

    International Nuclear Information System (INIS)

    Jeon, Seong Woo; Kim, See Hyung; Kwon, Sun Young

    2013-01-01

    Metastasis of malignant tumors to the kidney is clinically rare and often discovered by autopsy. Primary lymphoma and lung cancer are known that can metastasize to the kidney. Other malignant tumor metastasis to the kidney is very unusual. Primary cervical cancer metastasis to adjacent pelvic organs and lymph nodes are well known followed by abdominal solid organs such as the liver and adrenal glands. However, reported primary cervical cancer metastasis to the kidney is extremely rare and mostly appeared as bilateral multiple renal masses. We report here on a rare case of unilateral single renal metastasis from primary cervical cancer after concur- rent chemoradiotherapy.

  7. Prognostic value and staging classification of retropharyngeal lymph node metastasis in nasopharyngeal carcinoma patients treated with intensity-modulated radiotherapy.

    Directory of Open Access Journals (Sweden)

    Ling-Long Tang

    Full Text Available BACKGROUND: The development of intensity-modulated radiotherapy (IMRT has revolutionized the management of nasopharyngeal carcinoma (NPC. The purpose of this study was to evaluate the prognostic value and classification of TNM stage system for retropharyngeal lymph node (RLN metastasis in NPC in the IMRT era. MATERIAL AND METHODS: We retrospectively reviewed data from 749 patients with biopsy-proven, non-metastatic NPC. All patients received IMRT as the primary treatment. Chemotherapy was administered to 86.2% (424/492 of the patients with stage III or IV disease. RESULTS: The incidence of RLN metastasis was 64.2% (481/749. Significant differences were observed in the 5-year disease-free survival (DFS; 70.6% vs. 85.4%, P<0.001 and distant metastasis-free survival (DMFS; 79.2% vs. 90.1%, P<0.001 rates of patients with and without RLN metastasis. In multivariate analysis, RLN metastasis was an independent prognostic factor for disease failure and distant failure (P = 0.005 and P = 0.026, respectively, but not for locoregional recurrence. Necrotic RLN metastases have a negative effect on disease failure, distant failure and locoregional recurrence in NPC with RLN metastasis (P = 0.003, P = 0.018 and P = 0.005, respectively. Survival curves demonstrated a significant difference in DFS between patients with N0 disease and N1 disease with only RLN metastasis (P = 0.020, and marginally statistically significant differences in DMFS and DFS between N1 disease with only RLN metastasis and other N1 disease (P = 0.058 and P = 0.091, respectively. In N1 disease, no significant differences in DFS were observed between unilateral and bilateral RLN metastasis (P = 0.994. CONCLUSIONS: In the IMRT era, RLN metastasis remains an independent prognostic factor for DFS and DMFS in NPC. It is still reasonable for RLN metastasis to be classified in the N1 disease, regardless of laterality. However, there is a need to investigate the feasibility of classifying RLN

  8. Detection of Driver Drowsiness Using Wavelet Analysis of Heart Rate Variability and a Support Vector Machine Classifier

    Directory of Open Access Journals (Sweden)

    Gang Li

    2013-12-01

    Full Text Available Driving while fatigued is just as dangerous as drunk driving and may result in car accidents. Heart rate variability (HRV analysis has been studied recently for the detection of driver drowsiness. However, the detection reliability has been lower than anticipated, because the HRV signals of drivers were always regarded as stationary signals. The wavelet transform method is a method for analyzing non-stationary signals. The aim of this study is to classify alert and drowsy driving events using the wavelet transform of HRV signals over short time periods and to compare the classification performance of this method with the conventional method that uses fast Fourier transform (FFT-based features. Based on the standard shortest duration for FFT-based short-term HRV evaluation, the wavelet decomposition is performed on 2-min HRV samples, as well as 1-min and 3-min samples for reference purposes. A receiver operation curve (ROC analysis and a support vector machine (SVM classifier are used for feature selection and classification, respectively. The ROC analysis results show that the wavelet-based method performs better than the FFT-based method regardless of the duration of the HRV sample that is used. Finally, based on the real-time requirements for driver drowsiness detection, the SVM classifier is trained using eighty FFT and wavelet-based features that are extracted from 1-min HRV signals from four subjects. The averaged leave-one-out (LOO classification performance using wavelet-based feature is 95% accuracy, 95% sensitivity, and 95% specificity. This is better than the FFT-based results that have 68.8% accuracy, 62.5% sensitivity, and 75% specificity. In addition, the proposed hardware platform is inexpensive and easy-to-use.

  9. The detection rates and tumor clinical/pathological stages of whole-body FDG-PET cancer screening

    International Nuclear Information System (INIS)

    Ono, Ken; Omagari, Junichi; Ochiai, Reiji; Yoshida, Tsuyoshi; Kitagawa, Mami; Kobayashi, Hisashi; Yamashita, Yasuyuki

    2007-01-01

    Fluorodeoxyglucose (FDG)-positron emission tomography (PET) has been used for cancer screening, mainly in East-Asia, and cancers are found not infrequently. However, their stages have not been clarified. We examined the detection rates of various cancers using whole-body PET for the screening of cancers in asymptomatic individuals, focusing on their clinical and pathological stages. Whole-body PET was obtained as a part of our cancer screening program among 3,426 healthy subjects. All subjects participated in a course of PET examination in conjunction with conventional examinations including a medical questionnaire, tumor markers, immunological fecal occult blood test, neck and abdominal ultrasonography and whole body computed tomography. A diagnosis and staging was obtained by an analysis of the pathological findings or by an analysis of the clinical follow-up data. Malignant tumors were discovered in 65 lesions found in 3,426 participants (1.90%). The PET findings were true-positive in 46 of the 65 cancer cases. The cancers were found in the following organs: the colon 14; thyroid gland 10; stomach 7; lung 5; liver 3; breast 2; and one each in the kidney, gallbladder, esophagus, pancreas and retroperitoneum. The stages were as follows: stage 0 5, stage I 17, stage II 10, stage III 7, and stage IV 6. One was an unknown primary. There were 19 false-negative findings (0.6%) on PET. Six cancers (0.18%) were missed in our screening program. PET imaging has the potential to detect a wide variety of cancers at potentially curative stages. Most PET-negative cancers are early stage cancers, and thus can be detected using other conventional examinations such as endoscopy. (author)

  10. MRI-detection rate and incidence of lumbar bleeding sources in 190 patients with non-aneurysmal SAH.

    Directory of Open Access Journals (Sweden)

    Sepide Kashefiolasl

    Full Text Available Up to 15% of all spontaneous subarachnoid hemorrhages (SAH have a non-aneurysmal SAH (NASAH. The evaluation of SAH patients with negative digital subtraction angiography (DSA is sometimes a diagnostic challenge. Our goal in this study was to reassess the yield of standard MR-imaging of the complete spinal axis to rule out spinal bleeding sources in patients with NASAH.We retrospectively analyzed the spinal MRI findings in 190 patients with spontaneous NASAH, containing perimesencephalic (PM and non-perimesencephalic (NPM SAH, diagnosed by computer tomography (CT and/or lumbar puncture (LP, and negative 2nd DSA.190 NASAH patients were included in the study, divided into PM-SAH (n = 87; 46% and NPM-SAH (n = 103; 54%. Overall, 23 (22% patients had a CT negative SAH, diagnosed by positive LP. MR-imaging of the spinal axis detected two patients with lumbar ependymoma (n = 2; 1,05%. Both patients complained of radicular sciatic pain. The detection rate raised up to 25%, if only patients with radicular sciatic pain received an MRI.Routine radiological investigation of the complete spinal axis in NASAH patients is expensive and can not be recommended for standard procedure. However, patients with clinical signs of low-back/sciatic pain should be worked up for a spinal pathology.

  11. Water Exchange Produces Significantly Higher Adenoma Detection Rate Than Water Immersion: Pooled Data From 2 Multisite Randomized Controlled Trials.

    Science.gov (United States)

    Leung, Felix W; Koo, Malcolm; Cadoni, Sergio; Falt, Premysl; Hsieh, Yu-Hsi; Amato, Arnaldo; Erriu, Matteo; Fojtik, Petr; Gallittu, Paolo; Hu, Chi-Tan; Leung, Joseph W; Liggi, Mauro; Paggi, Silvia; Radaelli, Franco; Rondonotti, Emanuele; Smajstrla, Vit; Tseng, Chih-Wei; Urban, Ondrej

    2018-03-02

    To test the hypothesis that water exchange (WE) significantly increases adenoma detection rates (ADR) compared with water immersion (WI). Low ADR was linked to increased risk for interval colorectal cancers and related deaths. Two recent randomized controlled trials of head-to-head comparison of WE, WI, and traditional air insufflation (AI) each showed that WE achieved significantly higher ADR than AI, but not WI. The data were pooled from these 2 studies to test the above hypothesis. Two trials (5 sites, 14 colonoscopists) that randomized 1875 patients 1:1:1 to AI, WI, or WE were pooled and analyzed with ADR as the primary outcome. The ADR of AI (39.5%) and WI (42.4%) were comparable, significantly lower than that of WE (49.6%) (vs. AI P=0.001; vs. WI P=0.033). WE insertion time was 3 minutes longer than that of AI (Prate (vs. AI) of the >10 mm advanced adenomas. Right colon combined advanced and sessile serrated ADR of AI (3.4%) and WI (5%) were comparable and were significantly lower than that of WE (8.5%) (vs. AI P<0.001; vs. WI P=0.039). Compared with AI and WI, the superior ADR of WE offsets the drawback of a significantly longer insertion time. For quality improvement focused on increasing adenoma detection, WE is preferred over WI. The hypothesis that WE could lower the risk of interval colorectal cancers and related deaths should be tested.

  12. Role of protease activated receptor-2 in lymph node metastasis of uterine cervical cancers

    International Nuclear Information System (INIS)

    Jahan, Israt; Fujimoto, Jiro; Alam, Syed Mahfuzul; Sato, Eriko; Tamaya, Teruhiko

    2008-01-01

    Protease activated receptor-2 (PAR-2) has been implicated in cellular proliferation, invasion and metastasis in various tumors. Lymph node metastasis is an important patient prognostic factor for uterine cervical cancers. This prompted us to study the role of PAR-2 in lymph node metastasis of uterine cervical cancers. Thirty patients underwent surgery for uterine cervical cancers. PAR-2 histoscores and mRNA levels were determined by immunohistochemistry and real-time reverse transcription-polymerase chain reaction, respectively. Patient prognosis was analyzed with a 48-month survival rate. PAR-2 histoscores and mRNA levels significantly (P < 0.05) increased in 12 of 30 metastatic lymph node lesions from the corresponding primary tumor. The 48-month survival rate of the 12 patients with increased PAR-2 levels in metastatic lymph nodes was 42%, while the rate of the other 18 patients with no change in PAR-2 levels was 82%, regardless of histopathological type. PAR-2 might work on lymph node metastasis of uterine cervical cancers, and is considered to be a novel prognostic indicator for uterine cervical cancers

  13. Non-metastatic 2 (NME2)-mediated suppression of lung cancer metastasis involves transcriptional regulation of key cell adhesion factor vinculin

    Science.gov (United States)

    Thakur, Ram Krishna; Yadav, Vinod Kumar; Kumar, Akinchan; Singh, Ankita; Pal, Krishnendu; Hoeppner, Luke; Saha, Dhurjhoti; Purohit, Gunjan; Basundra, Richa; Kar, Anirban; Halder, Rashi; Kumar, Pankaj; Baral, Aradhita; Kumar, MJ Mahesh; Baldi, Alfonso; Vincenzi, Bruno; Lorenzon, Laura; Banerjee, Rajkumar; Kumar, Praveen; Shridhar, Viji; Mukhopadhyay, Debabrata; Chowdhury, Shantanu

    2014-01-01

    Tumor metastasis refers to spread of a tumor from site of its origin to distant organs and causes majority of cancer deaths. Although >30 metastasis suppressor genes (MSGs) that negatively regulate metastasis have been identified so far, two issues are poorly understood: first, which MSGs oppose metastasis in a tumor type, and second, which molecular function of MSG controls metastasis. Herein, integrative analyses of tumor-transcriptomes (n = 382), survival data (n = 530) and lymph node metastases (n = 100) in lung cancer patients identified non-metastatic 2 (NME2) as a key MSG from a pool of >30 metastasis suppressors. Subsequently, we generated a promoter-wide binding map for NME2 using chromatin immunoprecipitation with promoter microarrays (ChIP-chip), and transcriptome profiling. We discovered novel targets of NME2 which are involved in focal adhesion signaling. Importantly, we detected binding of NME2 in promoter of focal adhesion factor, vinculin. Reduced expression of NME2 led to enhanced transcription of vinculin. In comparison, NME1, a close homolog of NME2, did not bind to vinculin promoter nor regulate its expression. In line, enhanced metastasis of NME2-depleted lung cancer cells was found in zebrafish and nude mice tumor models. The metastatic potential of NME2-depleted cells was remarkably diminished upon selective RNA-i-mediated silencing of vinculin. Together, we demonstrate that reduced NME2 levels lead to transcriptional de-repression of vinculin and regulate lung cancer metastasis. PMID:25249619

  14. High Salt Intake Attenuates Breast Cancer Metastasis to Lung.

    Science.gov (United States)

    Xu, Yijuan; Wang, Wenzhe; Wang, Minmin; Liu, Xuejiao; Lee, Mee-Hyun; Wang, Mingfu; Zhang, Hao; Li, Haitao; Chen, Wei

    2018-04-04

    Diet-related factors are thought to modify the risk of cancers, while the influence of high salt intake remains largely uncharacterized. Breast cancer is the most common cancer in women worldwide. In the present study, we examined the effect of salt intake on breast cancer by using a 4T1 mouse mammary tumor model. Unexpectedly, both the fitness and the survival rate of the tumor-bearing mice were improved by high salt intake. Similarly, high salt intake suppressed the primary tumor growth as well as metastasis to lung in mice. Mechanistically, high salt intake greatly reduced food intake and thus might exert antitumor effect through mimicking calorie restriction. Immunoblotting showed the lower proliferation marker Ki-67 and the higher expression of the tumor suppressor gene p53 in tumors of high salt intake mice. Importantly, high salt intake might induce hyperosmotic stress, which sensitized breast cancer cells to p53-dependent anoikis. Collectively, our findings raise the possibility that endogenous salt deposition might act as the first-line defense system against breast cancer progression as well as metastasis.

  15. The application of surgical navigation system using optical molecular imaging technology in orthotopic breast cancer and metastasis studies

    Science.gov (United States)

    Chi, Chongwei; Zhang, Qian; Kou, Deqiang; Ye, Jinzuo; Mao, Yamin; Qiu, Jingdan; Wang, Jiandong; Yang, Xin; Du, Yang; Tian, Jie

    2014-02-01

    Currently, it has been an international focus on intraoperative precise positioning and accurate resection of tumor and metastases. The methods such as X-rays, computed tomography (CT), magnetic resonance imaging (MRI) and positron emission tomography (PET) have played an important role in preoperative accurate diagnosis. However, most of them are inapplicable for intraoperative surgery. We have proposed a surgical navigation system based on optical molecular imaging technology for intraoperative detection of tumors and metastasis. This system collects images from two CCD cameras for real-time fluorescent and color imaging. For image processing, the template matching algorithm is used for multispectral image fusion. For the application of tumor detection, the mouse breast cancer cell line 4T1-luc, which shows highly metastasis, was used for tumor model establishment and a model of matrix metalloproteinase (MMP) expressing breast cancer. The tumor-bearing nude mice were given tail vein injection of MMP 750FAST (PerkinElmer, Inc. USA) probe and imaged with both bioluminescence and fluorescence to assess in vivo binding of the probe to the tumor and metastases sites. Hematoxylin and eosin (H&E) staining was performed to confirm the presence of tumor and metastasis. As a result, one tumor can be observed visually in vivo. However liver metastasis has been detected under surgical navigation system and all were confirmed by histology. This approach helps surgeons to find orthotopic tumors and metastasis during intraoperative resection and visualize tumor borders for precise positioning. Further investigation is needed for future application in clinics.

  16. Natural killer (NK) cells inhibit systemic metastasis of glioblastoma cells and have therapeutic effects against glioblastomas in the brain.

    Science.gov (United States)

    Lee, Se Jeong; Kang, Won Young; Yoon, Yeup; Jin, Ju Youn; Song, Hye Jin; Her, Jung Hyun; Kang, Sang Mi; Hwang, Yu Kyeong; Kang, Kyeong Jin; Joo, Kyeung Min; Nam, Do-Hyun

    2015-12-24

    Glioblastoma multiforme (GBM) is characterized by extensive local invasion, which is in contrast with extremely rare systemic metastasis of GBM. Molecular mechanisms inhibiting systemic metastasis of GBM would be a novel therapeutic candidate for GBM in the brain. Patient-derived GBM cells were primarily cultured from surgical samples of GBM patients and were inoculated into the brains of immune deficient BALB/c-nude or NOD-SCID IL2Rgamma(null) (NSG) mice. Human NK cells were isolated from peripheral blood mononucleated cells and expanded in vitro. Patient-derived GBM cells in the brains of NSG mice unexpectedly induced spontaneous lung metastasis although no metastasis was detected in BALB/c-nude mice. Based on the difference of the innate immunity between two mouse strains, NK cell activities of orthotopic GBM xenograft models based on BALB/c-nude mice were inhibited. NK cell inactivation induced spontaneous lung metastasis of GBM cells, which indicated that NK cells inhibit the systemic metastasis. In vitro cytotoxic activities of human NK cells against GBM cells indicated that cytotoxic activity of NK cells against GBM cells prevents systemic metastasis of GBM and that NK cells could be effective cell therapeutics against GBM. Accordingly, NK cells transplanted into orthotopic GBM xenograft models intravenously or intratumorally induced apoptosis of GBM cells in the brain and showed significant therapeutic effects. Our results suggest that innate NK immunity is responsible for rare systemic metastasis of GBM and that sufficient supplementation of NK cells could be a promising immunotherapeutic strategy for GBM in the brain.

  17. Correlation of Slug gene expression with lymph node metastasis and invasion molecule expression in oral squamous cell carcinoma tissue

    Directory of Open Access Journals (Sweden)

    Shan-Ming Lu

    2017-10-01

    Full Text Available Objective: To study the correlation of Slug gene expression with lymph node metastasis and invasion molecule expression in oral squamous cell carcinoma tissue. Methods: Oral squamous cell carcinoma tissue surgical removed in Affiliated Stomatological Hospital of Nanjing Medical University between March 2015 and April 2017 was selected and divided into the oral squamous cell carcinoma tissue with neck lymph node metastasis and the oral squamous cell carcinoma tissues without lymph node metastasis according to the condition of lymph node metastasis. The expression of Slug, epithelial-mesenchymal transition molecules and invasion molecules in the oral squamous cell carcinoma tissue were detected. Results: Slug, N-cadherin, Vimentin, CD147, OPN, GRP78, SDF-1 and CXCR4 protein expression in oral squamous cell carcinoma tissue with neck lymph node metastasis were significantly higher than those in oral squamous cell carcinoma tissue without lymph node metastasis while E-cadherin, P120ctn and ZO-1 protein expression were significantly lower than those in oral squamous cell carcinoma tissue without lymph node metastasis; N-cadherin, Vimentin, CD147, OPN, GRP78, SDF-1 and CXCR4 protein expression in oral squamous cell carcinoma tissue with high Slug expression were significantly higher than those in oral squamous cell carcinoma tissue with low Slug expression while E-cadherin, P120ctn and ZO-1 protein expression were significantly lower than those in oral squamous cell carcinoma tissue with low Slug expression. Conclusion: The highly expressed Slug in oral squamous cell carcinoma tissue can promote the epithelial-mesenchymal transition and invasion of the cells to participate in the lymph node metastasis of tumor cells.

  18. Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT.

    Science.gov (United States)

    Shi, Bowen; Lin, Huimin; Zhang, Miao; Lu, Wei; Qu, Ying; Zhang, Huan

    2018-01-22

    Gastric cancer remains fourth in cancer incidence worldwide with a five-year survival of only 20%-30%. Peritoneal metastasis is the most frequent type of metastasis that accompanies unresectable gastric cancer and is a definitive determinant of prognosis. Preventing and controlling the development of peritoneal metastasis could play a role in helping to prolong the survival of gastric cancer patients. A non-invasive and efficient imaging technique will help us to identify the invasion and metastasis process of peritoneal metastasis and to monitor the changes in tumor nodules in response to treatments. This will enable us to obtain an accurate description of the development process and molecular mechanisms of gastric cancer. We have recently described experiment using dual energy CT (DECT) and positron emission tomography/computed tomography (PET/CT) platforms for the detection and monitoring of gastric tumor metastasis in nude mice models. We have shown that weekly continuous monitoring with DECT and PET/CT can identify dynamic changes in peritoneal metastasis. The sFRP1-overexpression in gastric cancer mice models showed positive radiological performance, a higher FDG uptake and increasing enhancement, and the SUVmax (standardized uptake value) of nodules demonstrated an obvious alteration trend in response to targeted therapy of TGF-β1 inhibitor. In this article, we described the detailed non-invasive imaging procedures to conduct more complex research on gastric cancer peritoneal metastasis using animal models and provided representative imaging results. The use of non-invasive imaging techniques should enable us to better understand the mechanisms of tumorigenesis, monitor tumor growth, and evaluate the effect of therapeutic interventions for gastric cancer.

  19. Application of semiquantitative analysis of whole body bone imaging on distal femoral metaphysis osseous metastasis of neuroblastoma

    International Nuclear Information System (INIS)

    Liu Yang; Wang Huixiang; Zhou Tao

    2012-01-01

    Objective: To evaluate the value of semiquantitative analysis of whole body bone imaging on distal femoral metaphysis osseous metastasis of neuroblastoma. Methods: Twenty-nine patients with confirmed neuroblastoma by pathological reports were divided into group of metastasis and group of no metastasis by bone marrow slides, X-ray, CT, MRI or clinical follow-up. Whole body bone imaging was performed pre-or postoperation. All cases were analysed by two methods: (1) Semi-quantitative analysis: Regions of interest on bilateral distal femoral metaphysic and middle of femoral were drawn, and their average counts were measured. The ratio of radioactivity of distal femoral metaphysic to middle of femoral was calculated; (2) Visual analysis:Bilateral distal femoral metaphysic metastasis were diagnosed by visual analysis according to whole body bone imaging. The differences between this two methods were compared. Results: There were differences of the ratio of radioactivity of distal femoral metaphysic to middle of femoral between group of metastasis and group of no metastasis (t =8.334, P<0.01), and there was no significant difference between t the two methods (χ 2 =0.68, P>0.05). The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of semiquantitative analysis in detecting osseous metastasis were 90.5% , 95.7% , 94.4% , 86.4% and 97.1% , while visual analysis were 81% , 100% , 95.6% , 100% and 94.5% . Conclusions: Radionuclide whole body bone imaging was of great importance in diagnosis of osseous metastasis of neuroblastoma. The diagnostic accuracy was improved by combination of visual analysis and semi-quantitative analysis. (authors)

  20. Human care system for heart-rate and human-movement trajectory in home and its application to detect mental disease

    Science.gov (United States)

    Hata, Yutaka; Kanazawa, Seigo; Endo, Maki; Tsuchiya, Naoki; Nakajima, Hiroshi

    2012-06-01

    This paper proposes a heart rate monitoring system for detecting autonomic nervous system by the heart rate variability using an air pressure sensor to diagnose mental disease. Moreover, we propose a human behavior monitoring system for detecting the human trajectory in home by an infrared camera. In day and night times, the human behavior monitoring system detects the human movement in home. The heart rate monitoring system detects the heart rate in bed in night time. The air pressure sensor consists of a rubber tube, cushion cover and pressure sensor, and it detects the heart rate by setting it to bed. It unconstraintly detects the RR-intervals; thereby the autonomic nervous system can be assessed. The autonomic nervous system analysis can examine the mental disease. While, the human behavior monitoring system obtains distance distribution image by an infrared camera. It classifies adult, child and the other object from distance distribution obtained by the camera, and records their trajectories. This behavior, i.e., trajectory in home, strongly corresponds to cognitive disorders. Thus, the total system can detect mental disease and cognitive disorders by uncontacted sensors to human body.

  1. Recruitment Methods and Show Rates to a Prostate Cancer Early Detection Program for High-Risk Men: A Comprehensive Analysis

    Science.gov (United States)

    Giri, Veda N.; Coups, Elliot J.; Ruth, Karen; Goplerud, Julia; Raysor, Susan; Kim, Taylor Y.; Bagden, Loretta; Mastalski, Kathleen; Zakrzewski, Debra; Leimkuhler, Suzanne; Watkins-Bruner, Deborah

    2009-01-01

    Purpose Men with a family history (FH) of prostate cancer (PCA) and African American (AA) men are at higher risk for PCA. Recruitment and retention of these high-risk men into early detection programs has been challenging. We report a comprehensive analysis on recruitment methods, show rates, and participant factors from the Prostate Cancer Risk Assessment Program (PRAP), which is a prospective, longitudinal PCA screening study. Materials and Methods Men 35–69 years are eligible if they have a FH of PCA, are AA, or have a BRCA1/2 mutation. Recruitment methods were analyzed with respect to participant demographics and show to the first PRAP appointment using standard statistical methods Results Out of 707 men recruited, 64.9% showed to the initial PRAP appointment. More individuals were recruited via radio than from referral or other methods (χ2 = 298.13, p < .0001). Men recruited via radio were more likely to be AA (p<0.001), less educated (p=0.003), not married or partnered (p=0.007), and have no FH of PCA (p<0.001). Men recruited via referrals had higher incomes (p=0.007). Men recruited via referral were more likely to attend their initial PRAP visit than those recruited by radio or other methods (χ2 = 27.08, p < .0001). Conclusions This comprehensive analysis finds that radio leads to higher recruitment of AA men with lower socioeconomic status. However, these are the high-risk men that have lower show rates for PCA screening. Targeted motivational measures need to be studied to improve show rates for PCA risk assessment for these high-risk men. PMID:19758657

  2. Cancer metabolism and the dynamics of metastasis.

    Science.gov (United States)

    Dattoli, G; Guiot, C; Delsanto, P P; Ottaviani, P L; Pagnutti, S; Deisboeck, T S

    2009-02-07

    Cancer growth dynamics, commonly simulated with a Gompertzian model, is analyzed in the framework of a more recent and realistic model. In particular, we consider the setting of a tumor embedded in a host organ and investigate their interaction. We assume that, at least in some cases, tumor metastasis may be triggered by an 'energetic crisis', when the tumor exceeds the 'carrying capacity' of the host organ. As a consequence, dissemination of clusters of cancer cells is set in motion, with a statistical probability given by a Poisson distribution. The model, although still at a preclinical level, is fully quantitative and is applied, as an example, to the case of prostate cancer. The results confirm that, at least for the more aggressive cancers, metastasis starts very early during tumorigenesis and a quantitative link is found between the tumor's doubling time, its 'aggressiveness' and the metastatic potential.

  3. Intramuscular metastasis from malignant melanoma: MR findings

    Energy Technology Data Exchange (ETDEWEB)

    Yoshioka, Hirohi; Itai, Yuji; Niitsu, Mamoru [Dept. of Radiology, Institute of Clinical Medicine, University of Tsukuba, Ibaraki (Japan); Fujiwara, Masachika; Watanabe, Teruo [Department of Pathology, Institute of Clinical Medicine, University of Tsukuba, Tsukuba (Japan); Satomi, Hisae; Otsuka, Fujio [Department of Dermatology, Institute of Clinical Medicine, University of Tsukuba, Tsukuba (Japan)

    1999-12-01

    We present a rare case of intramuscular metastasis from malignant melanoma. The lesion showed intermediate to high signal intensity on T1-weighted magnetic resonance (MR) images and mixed signal intensities containing high and low signals on T2-weighted images. The signal intensity on T1-weighted images, which is due to the paramagnetic effect of melanin, is a characteristic MR finding of this entity. (orig.)

  4. Mandibular metastasis of cholangiocarcinoma: A case report

    Energy Technology Data Exchange (ETDEWEB)

    You, Tae Min [Dept. of Advanced General Dentistry, Dankook University, Cheonan (Korea, Republic of); Kim, Kee Dong; Jeong, Ho Gui; Park, Won Se [Advanced General Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2015-12-15

    Tumors metastasizing from distant regions to the oral and maxillofacial region are uncommon, comprising only 1%-2% of all malignancies. Cholangiocarcinoma is a malignancy that arises from cholangiocytes, which are epithelial cells that line the bile ducts. These cancers are difficult to diagnose and have a poor prognosis. In this paper, we report a rare case of mandibular metastasis of cholangiocarcinoma diagnosed at the primary site and discuss the radiographic findings observed in this case.

  5. Isolated penile metastasis from bladder carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Demuren, O.A. [Department of Radiology and Imaging, Armed Forces Hospital, Riyadh (Saudi Arabia); Koriech, O. [Department of Oncology, Armed Forces Hospital, Riyadh (Saudi Arabia)

    1999-10-01

    Metastases of the penis are uncommon, with only approximately 300 cases reported since 1870. In up to 70 % of patients, the primary tumour is located in the urogenital tract. Furthermore, isolated metastases of the penis are exceptionally rare. We report a case of solitary squamous cell metastasis of the penis presenting with painful swelling initially thought to be inflammatory in origin. The CT and MR imaging findings are presented with a short review of the literature. (orig.) With 2 figs., 9 refs.

  6. The Role of Extracellular Vesicles in Metastasis

    Science.gov (United States)

    2017-10-01

    transferred via ESVs to osteoblasts. These bone cells represent the most common tissue target for breast cancer metastasis, and we will mimic ESV...separation of beads will result in good separation of bead-complexed exosomes and microvesicles. Furthermore, we show that we can use the same device to...proteins for 3 common exosome tetraspanin markers (CD9, CD63, and CD81) [Andreu & Yanez-Mo 2014] in tandem (pLLNL-exo-GFP) in order to both increase

  7. Prediction of Metastasis Using Second Harmonic Generation

    Science.gov (United States)

    2016-07-01

    small but statistically significant difference in average F/B of treated US patients versus untreated Dutch patients. Fig. 1. Display of all...predictive ability of models incorporating F/B using a multivariate linear model, but this time applying the analysis to the entire ER+ and ER- cohort. As...AWARD NUMBER: W81XWH-15-1-0040 TITLE: Prediction of Metastasis Using Second Harmonic Generation PRINCIPAL INVESTIGATOR: Edward Brown

  8. Ethanol inhibits B16-BL6 melanoma metastasis and cell phenotypes associated with metastasis.

    Science.gov (United States)

    Kushiro, Kyoko; Núñez, Nomelí P

    2012-01-01

    Every year, approximately 68,000 new cases of malignant melanoma are diagnosed in the US. Ethanol consumption inhibits metastasis of melanoma in mice, but the mechanism is not well understood. C57BL/6J ob/+ mice, given either water or 20% ethanol, were injected intravenously with B16-BL6 melanoma cells to determine pulmonary metastasis. The effects of ethanol on cell phenotypes and markers of the epithelial-to-mesenchymal transition were determined in cell culture. In mice, ethanol consumption inhibited experimental pulmonary metastasis. This inhibition was associated with decreased body weight, and levels of systemic leptin, and insulin. In cell culture, ethanol inhibited B16-BL6 cell motility, invasion, and anchorage-independent growth. Additionally, ethanol reduced Snai1 expression and increased E-cadherin expression. Lastly, ethanol increased the expression of Kiss1 metastasis-suppressor and the metastasis suppressor Nm23/nucleoside diphosphate kinase. In both animal and in cell culture conditions, ethanol inhibited the metastatic ability of B16-BL6 melanoma cells.

  9. Chemokines: novel targets for breast cancer metastasis

    Science.gov (United States)

    Ali, Simi; Lazennec, Gwendal

    2007-01-01

    Recent studies have highlighted the possible involvement of chemokines and their receptors in breast cancer progression and metastasis. Chemokines and their receptors constitute a superfamily of signalling factors whose prognosis value in breast cancer progression remains unclear. We will examine here the expression pattern of chemokines and their receptors in mammary gland physiology and carcinogenesis. The nature of the cells producing chemokines or harboring chemokine receptors appears to be crucial in certain conditions for example, the infiltration of the primary tumor by leukocytes and angiogenesis. In addition, chemokines, their receptors and the interaction with glycosaminoglycan (GAGs) are key players in the homing of cancer cells to distant metastasis sites. Several lines of evidence, including in vitro and in vivo models, suggest that the mechanism of action of chemokines in cancer development involves the modulation of proliferation, apoptosis, invasion, leukocyte recruitment or angiogenesis. Furthermore, we will discuss the regulation of chemokine network in tumor neovascularity by decoy receptors. The reasons accounting for the deregulation of chemokines and chemokine receptors expression in breast cancer are certainly crucial for the comprehension of chemokine role in breast cancer and are in several cases linked to estrogen receptor status. The targeting of chemokines and chemokine receptors by antibodies, small molecule antagonists, viral chemokine binding proteins and heparins appears as promising tracks to develop therapeutic strategies. Thus there is significant interest in developing strategies to antagonize the chemokine function, and an opportunity to interfere with metastasis, the leading cause of death in most patients. PMID:17717637

  10. Feasibility of mesorectal vascular invasion in predicting early distant metastasis in patients with stage T3 rectal cancer based on rectal MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Chul; Kim, Jai Keun; Lee, Jei Hee [Ajou University School of Medicine, Department of Radiology, Suwon, Gyeonggi-do (Korea, Republic of); Kim, Myeong-Jin [Yonsei University Health system, Department of Diagnostic Radiology, Institute of Gastroenterology, Research Institute of Radiological Science, Seoul (Korea, Republic of); Kim, Young Bae [Ajou University School of Medicine, Department of Pathology, Suwon (Korea, Republic of); Shin, Sung Jae [Ajou University School of Medicine, Department of Gastroenterology, Suwon (Korea, Republic of)

    2016-02-15

    To evaluate the feasibility of mesorectal vascular invasion (MVI) in predicting early distant metastasis developed within 1 year of diagnosis of T3 rectal cancer using magnetic resonance imaging (MRI) Sixty-five patients with T3 rectal cancer (early metastasis, n = 28; non-metastasis, n = 37) were enrolled in this study. Early distant metastases developed in 28 patients (liver, n = 15; lung, n = 9; both, n = 4). Logistic regression was used to determine the independent predictors for early distant metastasis. In univariate analysis, tumour location, carcinoembryonic antigen (CEA), lymphovascular invasion (LVI), MRI-detected MVI, and mesorectal fat infiltration (MFI) (odds ratio [OR], 4.533, 9.583, 5.539, 27.046, and 5.539, respectively) were associated with early distant metastasis. Multivariate analysis demonstrated that MVI (OR, 29.949; P < 0.002) and LVI (OR, 6.684; P = 0.033) were independent factors for early distant metastasis. Specificity and positive predictive value (PPV) of MVI (94.59 %, and 89.47 %, respectively) were significantly higher than those of LVI (64.86 %, and 61.76 %), but sensitivity and negative predictive value were not significantly different between MVI (60.71 %, and 76.09 %) and LVI (75.00 %, and 77.42 %). While sensitivity of MRI-detected MVI was equal to that of CEA in predicting early distant metastasis from T3 rectal cancer, specificity and PPV may be improved by assessing MVI. (orig.)

  11. Effect of layer number on recovery rate of WS{sub 2} nanosheets for ammonia detection at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Qin, Ziyu [State Key Laboratory of Materials Processing and Die Mould Technology, Huazhong University of Science and Technology (HUST), No. 1037, Luoyu Road, Wuhan 430074 (China); Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials, Hubei University, Wuhan 430062 (China); Zeng, Dawen, E-mail: dwzeng@mail.hust.edu.cn [State Key Laboratory of Materials Processing and Die Mould Technology, Huazhong University of Science and Technology (HUST), No. 1037, Luoyu Road, Wuhan 430074 (China); Hubei Collaborative Innovation Center for Advanced Organic Chemical Materials, Hubei University, Wuhan 430062 (China); Zhang, Jia; Wu, Congyi; Wen, Yanwei; Shan, Bin; Xie, Changsheng [State Key Laboratory of Materials Processing and Die Mould Technology, Huazhong University of Science and Technology (HUST), No. 1037, Luoyu Road, Wuhan 430074 (China)

    2017-08-31

    Highlights: • Reasons for room-temperature difficult recovery of WS{sub 2} sensors for NH{sub 3} detection. • The excellent recovery within 271.9 s was observed for single-layer WS{sub 2} sensor. • The recovery time of WS{sub 2} sensor has a anti-linear relation with number of layer. - Abstract: Tungsten disulfide (WS{sub 2}), as a representative layered transition metal dichalcogenides (TMDs), is expected as a promising candidate for high-performance NH{sub 3} sensor at room temperature. Unfortunately, the common WS{sub 2} based NH{sub 3} sensors are difficult to recovery at room temperature, which severely limits its application. Hence, how to improve recovery has become an urgent problem to be solved. Herein, we prepare five types of WS{sub 2} nanosheets with different layer numbers from bulk to monolayer, and find that the recovery time of NH{sub 3} gas sensor is rapidly linear shorten as the number of layers decreasing. Through the first-principles calculation of the interaction between NH{sub 3} and WS{sub 2} substance, the different binding energy between ammonia and the surface (−0.179 eV) and interlayer (−0.356 eV) of layered WS{sub 2}, as well as the different electron transfer way, should be responsible for the difficult recovery rate of various WS{sub 2} samples. Therefore, reducing the number of layer of WS{sub 2} is a promising approach to speed up recovery. Based on this conclusion, we successfully prepare a fast recoverable ammonia gas sensor based on single layer WS{sub 2}, which exhibits exciting fast recovery within 271.9 s at room temperature without any condition. Moreover, our work also can act as a reference for other gas detection of TMDs based gas sensor to improve the gas performance at room-temperature.

  12. A new islanding detection technique for multiple mini hydro based on rate of change of reactive power and load connecting strategy

    International Nuclear Information System (INIS)

    Laghari, J.A.; Mokhlis, H.; Bakar, A.H.A.; Karimi, M.

    2013-01-01

    Highlights: • The requirement of DG interconnection with existing power system is discussed. • Various islanding detection techniques are discussed with their merits and demerits. • New islanding detection strategy is proposed for multiple mini hydro type DGs. • The proposed strategy is based on dq/dt and load connecting strategy. • The effectiveness of strategy is verified on various other cases. - Abstract: The interconnection of distributed generation (DG) into distribution networks is undergoing a rapid global expansion. It enhances the system’s reliability, while simultaneously reduces pollution problems related to the generation of electrical power. To fully utilize the benefits of DGs, certain technical issues need to be addressed. One of the most important issues in this context is islanding detection. This paper presents a new islanding detection technique that is suitable for multiple mini-hydro type DG units. The proposed strategy is based on the rate of change of reactive power and load connecting strategy to detect islanding within the system. For a large power mismatch, islanding is detected by rate of change of reactive power only. However, for a close power mismatch, the rate of change of reactive power initiates a load connecting strategy, which in turn alters the load on the distribution network. This load variation in the distribution network causes a variation in the rate of change of reactive power, which is utilized to distinguish islanding and other events. The simulation results show that the proposed strategy is effective in detecting islanding occurrence in a distribution network

  13. Gastric Metastasis of Ectopic Breast Cancer Mimicking Axillary Metastasis of Primary Gastric Cancer

    Directory of Open Access Journals (Sweden)

    Selami Ilgaz Kayılıoğlu

    2014-01-01

    Full Text Available Ectopic breast tissue has the ability to undergo all the pathological changes of the normal breast, including breast cancer. Gastrointestinal metastasis of breast cancer is rarely observed and it is very difficult to differentiate gastric metastases from primary gastric cancer. We present a case of 52-year-old female, who suffered from abdominal pain. Physical examination showed a palpable mass in the left anterior axilla and computerized tomography revealed gastric wall thickening with linitis plastica. When gastroscopic biopsy showed no signs of malignancy, excisional biopsy was performed in the left axilla. Histological examination revealed invasive lobular carcinoma of the breast, consistent with ectopic breast cancer. Further gastroscopic submucosal biopsies and immunohistochemical studies revealed gastric metastases of invasive lobular carcinoma. Axillary ectopic breast tissue carcinomas can mimic axillary lymphadenopathies. Additionally, gastric metastasis of breast cancer is an uncommon but possible condition. To the best of our knowledge, this is the first report of ectopic breast cancer with gastric metastasis.

  14. Risk factors and the preoperative assessment of right para-oesophageal lymph node metastasis in right lobe papillary thyroid carcinoma: A case series.

    Science.gov (United States)

    Qu, You; Zhang, Hao; Zhang, Ping; Dong, Wenwu; He, Liang; Sun, Wei; Liu, Jinhao

    2017-06-01

    Right para-oesophageal lymph nodes (RPELN) are included among the right central compartment lymph nodes (rCLN) and located behind right recurrent laryngeal nerve (rRLN). However, due to the likelihood of increasing postoperative complications, and the extremely difficulties of RPELN dissection, the decision to perform RPELN dissection remains controversial. The aim of this study was to explore the risk factors of RPELN metastasis and evaluate RPELN metastasis by preoperative examination. We reviewed the medical records of 163 consecutive papillary thyroid carcinoma (PTC) patients (125 females and 38 males) who underwent right lobe plus isthmic resection (91 patients) or total thyroidectomy (72 patients) with right or bilateral central compartment lymph node dissection. The RPELN dissections were performed in all patients and were individually dissected and recorded intraoperatively. All patients underwent thyroid ultrasound and enhanced neck computed tomography (CT) routinely during preoperative examination. RPELN metastasis was detected in 20 patients (12.3%), among whom 6 (3.7%) had RPELN metastasis without rCLN metastasis. Total rCLN metastasis and lateral compartment lymph node metastasis were confirmed in 57 (35.0%) and 24 (14.7%) patients, respectively. The tumour diameter, number of metastatic rCLN and lateral compartment lymph nodes, RPELN visible on CT, and enhanced CT value of RPELN were confirmed significantly associated with RPELN metastasis by univariate analysis (P 1 cm) in the right lobe or suspected rCLN metastasis were recommended to undergo prophylactic RPELN dissection, particularly in those with a high enhanced CT value (>132) of RPELN or those with the copresence of lateral compartment lymph node metastasis. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  15. The concentration of erlotinib in the cerebrospinal fluid of patients with brain metastasis from non-small-cell lung cancer

    Science.gov (United States)

    DENG, YANMING; FENG, WEINENG; WU, JING; CHEN, ZECHENG; TANG, YICONG; ZHANG, HUA; LIANG, JIANMIAO; XIAN, HAIBING; ZHANG, SHUNDA

    2014-01-01

    It has been demonstrated that erlotinib is effective in treating patients with brain metastasis from non-small-cell lung cancer. However, the number of studies determining the erlotinib concentration in these patients is limited. The purpose of this study was to measure the concentration of erlotinib in the cerebrospinal fluid of patients with brain metastasis from non-small-cell lung carcinoma. Six patients were treated with the standard recommended daily dose of erlotinib (150 mg) for 4 weeks. All the patients had previously received chemotherapy, but no brain radiotherapy. At the end of the treatment period, blood plasma and cerebrospinal fluid samples were collected and the erlotinib concentration was determined by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The average erlotinib concentration in the blood plasma and the cerebrospinal fluid was 717.7±459.7 and 23.7±13.4 ng/ml, respectively. The blood-brain barrier permeation rate of erlotinib was found to be 4.4±3.2%. In patients with partial response (PR), stable disease (SD) and progressive disease (PD), the average concentrations of erlotinib in the cerebrospinal fluid were 35.5±19.0, 19.1±8.7 and 16.4±5.9 ng/ml, respectively. In addition, the efficacy rate of erlotinib for metastatic brain lesions was 33.3%, increasing to 50% in patients with EGFR mutations. However, erlotinib appeared to be ineffective in cases with wild-type EGFR. In conclusion, a relatively high concentration of erlotinib was detected in the cerebrospinal fluid of patients with brain metastases from non-small-cell lung cancer. Thus, erlotinib may be considered as a treatment option for this patient population. PMID:24649318

  16. Uterine cervical cancer with brain metastasis as the initial site of presentation.

    Science.gov (United States)

    Sato, Yumi; Tanaka, Kei; Kobayashi, Yoichi; Shibuya, Hiromi; Nishigaya, Yoshiko; Momomura, Mai; Matsumoto, Hironori; Iwashita, Mitsutoshi

    2015-07-01

    Brain metastasis from uterine cervical cancer is rare, with an incidence of 0.5%, and usually occurs late in the course of the disease. We report a case of uterine cervical cancer with brain metastasis as the initial site of presentation. A 50-year-old woman with headache, vertigo, amnesia and loss of appetite was admitted for persistent vomiting. Contrast enhanced computed tomography showed a solitary right frontal cerebral lesion with ring enhancement and uterine cervical tumor. She was diagnosed with uterine cervical squamous cell carcinoma with parametrium invasion and no other distant affected organs were detected. The cerebral lesion was surgically removed and pathologically proved to be metastasis of uterine cervical squamous cell carcinoma. The patient underwent concurrent chemoradiotherapy, followed by cerebral radiation therapy, but multiple metastases to the liver and lung developed and the patient died 7 months after diagnosis of brain metastasis. © 2015 The Authors. Journal of Obstetrics and Gynaecology Research © 2015 Japan Society of Obstetrics and Gynecology.

  17. Detection of D2-40 monoclonal antibody-labeled lymphatic vessel invasion in esophageal squamous cell carcinoma and its clinicopathologic significance

    International Nuclear Information System (INIS)

    Bai, Bing; Ma, Wei; Wang, Kai; Ha, Sita; Wang, Jian-Bo; Tan, Bing-Xu; Wang, Na-Na; Yang, Sheng-Si; Jia, Yi-Bin; Cheng, Yu-Feng

    2013-01-01

    This study aims to investigate the clinicopathologic significance of lymphatic vessel invasion (LVI) labeled by D2-40 monoclonal antibody in esophageal squamous cell carcinoma (ESCC). Immunohistochemical assay was used to detect the expression of D2-40 and LVI in 107 ESCC patients. Then, the correlation between the clinicopathologic feature and the overall survival time of the patients was analyzed. The lymph node metastasis rates were 70% and 21% in the LVI-positive and LVI-negative groups, respectively. The nodal metastasis rate was higher in the LVI-positive group than in the LVI-negative group. Multivariate regression analysis showed that LVI was related to nodal metastasis (P<0.001). The median survival time of the patients was 26 and 43 months in the LVI-positive and LVI-negative groups, respectively. Although univariate regression analysis showed significant difference between the two groups (P=0.014), multivariate regression analysis revealed that LVI was not an independent prognostic factor for overall survival in the ESCC patients (P=0.062). Lymphatic node metastasis (P=0.031), clinical stage (P=0.019), and residual tumor (P=0.026) were the independent prognostic factors. LVI labeled by D2-40 monoclonal antibody is a risk factor predictive of lymph node metastasis in ESCC patients

  18. A Bayesian network meta-analysis of whole brain radiotherapy and stereotactic radiotherapy for brain metastasis.

    Science.gov (United States)

    Yuan, Xi; Liu, Wen-Jie; Li, Bing; Shen, Ze-Tian; Shen, Jun-Shu; Zhu, Xi-Xu

    2017-08-01

    This study was conducted to compare the effects of whole brain radiotherapy (WBRT) and stereotactic radiotherapy (SRS) in treatment of brain metastasis.A systematical retrieval in PubMed and Embase databases was performed for relative literatures on the effects of WBRT and SRS in treatment of brain metastasis. A Bayesian network meta-analysis was performed by using the ADDIS software. The effect sizes included odds ratio (OR) and 95% confidence interval (CI). A random effects model was used for the pooled analysis for all the outcome measures, including 1-year distant control rate, 1-year local control rate, 1-year survival rate, and complication. The consistency was tested by using node-splitting analysis and inconsistency standard deviation. The convergence was estimated according to the Brooks-Gelman-Rubin method.A total of 12 literatures were included in this meta-analysis. WBRT + SRS showed higher 1-year distant control rate than SRS. WBRT + SRS was better for the 1-year local control rate than WBRT. SRS and WBRT + SRS had higher 1-year survival rate than the WBRT. In addition, there was no difference in complication among the three therapies.Comprehensively, WBRT + SRS might be the choice of treatment for brain metastasis.

  19. Does preoperative breast MRI significantly impact on initial surgical procedure and re-operation rates in patients with screen-detected invasive lobular carcinoma?

    International Nuclear Information System (INIS)

    Sinclair, K.; Sakellariou, S.; Dawson, N.; Litherland, J.

    2016-01-01

    Aim: To investigate whether magnetic resonance imaging (MRI) changes the management of patients with screen-detected invasive lobular carcinoma (ILC). Materials and methods: A retrospective, controlled, single-centre analysis of 138 cases of screen-detected ILC was performed. All patients were assessed by a single multidisciplinary team as to whether preoperative MRI altered the initial management decision or reduced re-operation rates. Results: Forty-three percent of patients had preoperative MRI. MRI guided surgical management in 40.7% patients. Primary mastectomy rates were not significantly different between the MRI and non-MRI groups (32% and 30% respectively, p=0.71). The MRI group had a lower secondary surgery rate (6.8% versus 15.2%); however, the results did not reach statistical significance, and there were no unnecessary mastectomies. Conclusion: MRI can be used appropriately to guide primary surgery in screen-detected ILC cases and affects the initial management decision in 40.7% of patients. It does not significantly affect the overall mastectomy rate or re-operation rates, but reduces the likelihood of the latter. As a result of this review, the authors' local policy for the use of MRI in screen-detected ILC patients has been modified. For patients undergoing mastectomy for ILC, MRI is no longer performed routinely to search for contralateral malignancy as this has no proven added benefit. - Highlights: • Breast magnetic resonance imaging (MRI) allows more accurate tumour assessment and detects additional foci of disease in invasive lobular carcinoma (ILC). • Over the study's 3 year time frame, MRI guided surgical management of 40.7% screen-detected ILC patients scanned. • No statistically significant difference in mastectomy rates between MRI and non MRI groups. • Observed lower re-operation rate (6.8%-v-15.2%) in MRI group not statistically significant. • No MRI benefit for contralateral disease detection in ILC patients for

  20. The effect of changing from one to two views at incident (subsequent) screens in the NHS breast screening programme in England: impact on cancer detection and recall rates

    International Nuclear Information System (INIS)

    Blanks, R.G.; Bennett, R.L.; Patnick, J.; Cush, S.; Davison, C.; Moss, S.M.

    2005-01-01

    AIM: To assess the effect on cancer detection and recall rates of changing from one to two views for incident (subsequent) screens. METHODS: Controlled, comparative, observational study of programmes in NHS breast screening programme in England. Subjects: women aged 50-64 years were screened by the NHSBSP between 1 April 2001 and 31 March 2003. RESULTS: The effect of changing to two-view mammography was a 20% increase in overall incident screen cancer detection rate, with the biggest effect seen for small (<15 mm) invasive cancers. This increased detection rate was achieved with an 11% drop-in recall rate. CONCLUSION: The introduction of two-view mammography for incident screens has resulted in considerable improvements in overall NHS breast screening performance