WorldWideScience

Sample records for medical devices ophthalmic

  1. 78 FR 68714 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug

    Science.gov (United States)

    2013-11-15

    ... amendments), as ``preamendments devices.'' FDA classifies these devices after the Agency takes the following.... FDA-2012-N-1238] Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug AGENCY: Food... scleral plugs in order to provide a reasonable assurance of safety and effectiveness of the device. The...

  2. 21 CFR 886.1420 - Ophthalmic lens gauge.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic lens gauge. 886.1420 Section 886.1420...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1420 Ophthalmic lens gauge. (a) Identification. An ophthalmic lens gauge is a calibrated device intended to manually measure the curvature of a...

  3. 21 CFR 886.4230 - Ophthalmic knife test drum.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic knife test drum. 886.4230 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4230 Ophthalmic knife test drum. (a) Identification. An ophthalmic knife test drum is a device intended to test the keenness of ophthalmic surgical...

  4. 21 CFR 886.5800 - Ophthalmic bar reader.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic bar reader. 886.5800 Section 886.5800...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5800 Ophthalmic bar reader. (a) Identification. An ophthalmic bar reader is a device that consists of a magnifying lens intended for use by a...

  5. 21 CFR 886.1650 - Ophthalmic bar prism.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic bar prism. 886.1650 Section 886.1650...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1650 Ophthalmic bar prism. (a) Identification. An ophthalmic bar prism is a device that is a bar composed of fused prisms of gradually increasing...

  6. 21 CFR 886.4750 - Ophthalmic eye shield.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4750 Ophthalmic eye shield. (a) Identification. An ophthalmic eye shield is a device that consists of a plastic or aluminum eye covering intended to... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic eye shield. 886.4750 Section 886.4750...

  7. 21 CFR 886.3100 - Ophthalmic tantalum clip.

    Science.gov (United States)

    2010-04-01

    ... blood vessels in the eye. (b) Classification. Class II (special controls). The device is exempt from the...) MEDICAL DEVICES OPHTHALMIC DEVICES Prosthetic Devices § 886.3100 Ophthalmic tantalum clip. (a) Identification. An ophthalmic tantalum clip is a malleable metallic device intended to be implanted permanently...

  8. 21 CFR 886.1410 - Ophthalmic trial lens clip.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens clip. 886.1410 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1410 Ophthalmic trial lens clip. (a) Identification. An ophthalmic trial lens clip is a device intended to hold prisms, spheres, cylinders, or...

  9. 21 CFR 886.1405 - Ophthalmic trial lens set.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens set. 886.1405 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1405 Ophthalmic trial lens set. (a) Identification. An ophthalmic trial lens set is a device that is a set of lenses of various dioptric powers...

  10. 21 CFR 886.1415 - Ophthalmic trial lens frame.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic trial lens frame. 886.1415 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1415 Ophthalmic trial lens frame. (a) Identification. An opthalmic trial lens frame is a mechanical device intended to hold trial lenses for vision...

  11. Allergic Contact Dermatitis to Ophthalmic Medications: Relevant Allergens and Alternative Testing Methods.

    Science.gov (United States)

    Grey, Katherine R; Warshaw, Erin M

    Allergic contact dermatitis is an important cause of periorbital dermatitis. Topical ophthalmic agents are relevant sensitizers. Contact dermatitis to ophthalmic medications can be challenging to diagnose and manage given the numerous possible offending agents, including both active and inactive ingredients. Furthermore, a substantial body of literature reports false-negative patch test results to ophthalmic agents. Subsequently, numerous alternative testing methods have been described. This review outlines the periorbital manifestations, causative agents, and alternative testing methods of allergic contact dermatitis to ophthalmic medications.

  12. 21 CFR 886.4790 - Ophthalmic sponge.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic sponge. 886.4790 Section 886.4790 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4790 Ophthalmic sponge. (a) Identification. An ophthalmic sponge is a device that is an absorbant sponge, pad, or spear made of folded gauze, cotton...

  13. 21 CFR 886.4390 - Ophthalmic laser.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ophthalmic laser. 886.4390 Section 886.4390 Food... DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4390 Ophthalmic laser. (a) Identification. An ophthalmic laser is an AC-powered device intended to coagulate or cut tissue of the eye, orbit, or surrounding skin...

  14. Outpatients flow management and ophthalmic electronic medical records system in university hospital using Yahgee Document View.

    Science.gov (United States)

    Matsuo, Toshihiko; Gochi, Akira; Hirakawa, Tsuyoshi; Ito, Tadashi; Kohno, Yoshihisa

    2010-10-01

    General electronic medical records systems remain insufficient for ophthalmology outpatient clinics from the viewpoint of dealing with many ophthalmic examinations and images in a large number of patients. Filing systems for documents and images by Yahgee Document View (Yahgee, Inc.) were introduced on the platform of general electronic medical records system (Fujitsu, Inc.). Outpatients flow management system and electronic medical records system for ophthalmology were constructed. All images from ophthalmic appliances were transported to Yahgee Image by the MaxFile gateway system (P4 Medic, Inc.). The flow of outpatients going through examinations such as visual acuity testing were monitored by the list "Ophthalmology Outpatients List" by Yahgee Workflow in addition to the list "Patients Reception List" by Fujitsu. Patients' identification number was scanned with bar code readers attached to ophthalmic appliances. Dual monitors were placed in doctors' rooms to show Fujitsu Medical Records on the left-hand monitor and ophthalmic charts of Yahgee Document on the right-hand monitor. The data of manually-inputted visual acuity, automatically-exported autorefractometry and non-contact tonometry on a new template, MaxFile ED, were again automatically transported to designated boxes on ophthalmic charts of Yahgee Document. Images such as fundus photographs, fluorescein angiograms, optical coherence tomographic and ultrasound scans were viewed by Yahgee Image, and were copy-and-pasted to assigned boxes on the ophthalmic charts. Ordering such as appointments, drug prescription, fees and diagnoses input, central laboratory tests, surgical theater and ward room reservations were placed by functions of the Fujitsu electronic medical records system. The combination of the Fujitsu electronic medical records and Yahgee Document View systems enabled the University Hospital to examine the same number of outpatients as prior to the implementation of the computerized filing system.

  15. Are we pharmacovigilant enough in ophthalmic practice?

    Directory of Open Access Journals (Sweden)

    Ashok Dubey

    2013-01-01

    Full Text Available No drug is absolutely safe. Pharmacovigilance is the science related to detection, assessment, understanding and prevention of adverse effects or any other possible drug-related problems. The ocular medications and devices can cause localized and systemic adverse effects. Not all adverse effects are known when a drug or device is launched in market because of limitations of clinical trials. Many adverse effects are recognized due to the spontaneous reporting of the vigilant doctors who observe and report such events encountered in their practice. Despite a large ophthalmic patient population base, India does not have robust adverse drug reaction (ADR database because of lack of reporting culture. Government of India recently launched the Pharmacovigilance Programme of India (PvPI to monitor ADRs and create awareness among the healthcare professionals about the importance of ADRs. Suspecting and reporting a possible drug reaction is very important in developing a safe and rational ophthalmic practice.

  16. RESULTS OF THE SURVEY CONDUCTED AMONG OPHTHALMOLOGISTS ON THE ISSUE OF EQUIPMENT OF MEDICAL INSTITUTIONS WITH OPHTHALMOLOGY DEVICES

    Directory of Open Access Journals (Sweden)

    S. V. Seraphimov

    2017-01-01

    Full Text Available Introduction. The problem of limited accessibility and quality of ophthalmic medical care remains one of the leading ones in the national healthcare. This article presents results of the survey conducted among ophthalmologists about the effect of large-scale equipment of all medical institutions in the Leningrad Region with modern ophthalmologic devices over the recent years.Objective is to determine the contribution of the health care modernization program to equipping the medical institutions of the Leningrad Region with modern ophthalmologic medical devices, and to identify the main areas for improving the ophthalmologic care for residents of the Leningrad region with cataracts.Materials and methods. According to a specially developed questionnaire, 105 ophthalmologists from the Leningrad Region were interviewed. The survey was conducted among physicians working both in out-patient medical facilities and in medical facilities with in-patient modalities.Results. The results of the study confirmed positive changes that occurred in recent years as a result of equipping medical institutions with modern medical devices. Almost two-thirds (59.9% of respondents noted that equipping with modern medical devices had a significant impact on the quality of the medical and diagnostic measures carried out in healthcare facilities of the region.Conclusions. The equipment had a significant impact on the diagnosis and treatment of all kinds of diseases of the eye and its appendages, especially such eye disease which is so common among the population of the Leningrad Region as cataracts (75.0 per 100 ophthalmologists surveyed. At the same time, in spite of these efforts, the standard for equipping ophthalmologic departments in individual medical institutions has not been fully provided. Only every fifth (20.9% ophthalmologist noted during the survey that the list of available ophthalmic devices was sufficient, and that they all worked properly.

  17. Medical device development: managing conflicts of interest encountered by physicians.

    Science.gov (United States)

    Baim, Donald S; Donovan, Aine; Smith, John J; Briefs, Nancy; Geoffrion, Richard; Feigal, David; Kaplan, Aaron V

    2007-04-01

    New technologies introduced over the past three decades have transformed medical diagnosis and treatment, and significantly improved patient outcomes. These changes have been mediated by the introduction of new medical devices, particularly for the treatment of cardiovascular, orthopedic, and ophthalmic disorders. These devices, in turn, have created large markets and spawned a burgeoning medical device industry, including six Fortune 500 companies whose combined market capitalization now exceeds 400 billion dollars. This success story, which has unquestionably benefited patients and society alike, has been dependent upon an intense collaboration among industry, clinicians, and regulatory authorities. However, when physicians actively involved in patient care participate in such collaborations, they are increasingly vulnerable to creating potential conflicts between these two (clinical and device development) roles. Such conflicts, which may ultimately erode public trust, have important consequences not only for the individual physicians, but also for their parent institutions, their patients, sponsoring companies, and the entire clinical research enterprise that makes the development and introduction of new devices possible. The third Dartmouth Device Development Symposium held in October 2005 brought together thought leaders within the medical device community, including academicians, clinical investigators, regulators from the Food and Drug Administration and Centers for Medicare and Medicaid Services (CMS), large and small device manufacturers and the financial (venture capital and investment banks) community. The Symposium examined the conflicts of interest encountered during the early development and commercialization of a medical device. The goal of these discussions was to (1) identify and characterize the conflicts that arise and (2) provide strategies to address these conflicts. This manuscript was prepared by a writing committee to provide a summary

  18. Medical physics aspects of ophthalmic brachytherapy

    International Nuclear Information System (INIS)

    Sharma, S.D.; Shanta, A.; Palani Selvam, T.; Tripathi, U.B.; Bhatt, B.C.

    2004-11-01

    Intraocular melanoma is the most common primary malignancy of the eye. Radiation therapy using ophthalmic plaque has proved successful in the management of various ocular lesions. Although a few centres were using 90 Sr/ 90 Y plaques for shallow turtlours some years ago, eye plaque therapy was not a common practice in India. A revived interest in the use of eye plaque therapy and very high cost of imported sources has led to the development and production of 125 I seed sources by the Radiopharmaceuticals Division, BARC. This report presents a brief description on the clinical, dosimetry and radiation safety aspects of 90 Sr/ 90 Y and 106 Ru/ 106 Rh beta ray and 125 I gamma ray eye plaque applicators. This report has been divided in five Sections. Section I presents general introduction of ophthalmic brachytherapy including the structure of a human eye, types of ophthalmic plaques and characteristics of radioisotopes commonly used in such applications. A brief review of sources, applicators and dosimetry of 90 Sr/ 90 Y and 106 Ru/ 106 Rh beta and 125 I gamma ophthalmic plaques are given in Section II and Section III, respectively. Section IV contains the single seed dosimetry data of BARC OcuProsta 125 I seed as well as dosimetry data of typical eye plaques loaded with BARC OcuProsta 125 I seed. Quality assurance and radiation safety aspects of these eye applicators are described in Section V. A proforma of the application required to be filled in by the user institution for obtaining regulatory consent to start eye plaque therapy has also been appended to this report. (author)

  19. Effect of incisional friction and ophthalmic viscosurgical devices on the heat generation of ultrasound during cataract surgery.

    Science.gov (United States)

    Floyd, Michael; Valentine, Jeremy; Coombs, Jamie; Olson, Randall J

    2006-07-01

    To determine the thermal features of the Legacy (Alcon) and Sovereign (Advanced Medical Optics) phacoemulsification machines in a cadaver eye and with 7 ophthalmic viscosurgical devices (OVDs). In situ and in vitro study. Temperature without occlusion was recorded at the sleeve placed in the wound of a cadaver eye, and temperature over baseline was determined after 60 seconds. The result was then compared with the results in a previous study that used balanced salt solution (BSS) in artificial chambers. In the second portion of the experiment, with irrigation and aspiration lines occluded, temperature was recorded at the sleeve placed in an artificial chamber filled with sodium hyaluronate 2.3% (Healon5), sodium hyaluronate 1.4% (Healon GV), sodium hyaluronate 1.0% (Healon), sodium hyaluronate 1.6% (Amvisc Plus), sodium hyaluronate 1.0% (Provisc), sodium hyaluronate 3.0%-chondroitin sulfate 4.0% (Viscoat), or hyaluronate 3.0% (Vitrax). Temperature over baseline was also determined after 60 seconds. These results were compared with each set of OVD data and with the results in the prior BSS study. In the eye-bank model, the Legacy machine had a 62% temperature increase from incisional friction and the Sovereign machine had a decrease of 8.6% over results in an artificial anterior chamber. The OVD temperature increases were greater for the Sovereign (Pgeneration in the Legacy, a stroke-length driven instrument, more than in the Sovereign, a power-driven instrument. Ophthalmic viscosurgical devices are not only a concern due to outflow occlusion but can also add up to 6 times the heat in comparison with BSS. The need to aspirate the OVD before using ultrasound is thus verified.

  20. Ophthalmic Disorders in Adults with Down Syndrome

    Directory of Open Access Journals (Sweden)

    Sharon J. Krinsky-McHale

    2012-01-01

    Full Text Available A myriad of ophthalmic disorders is associated with the phenotype of Down syndrome including strabismus, cataracts, and refractive errors potentially resulting in significant visual impairment. Ophthalmic sequelae have been extensively studied in children and adolescents with Down syndrome but less often in older adults. In-depth review of medical records of older adults with Down syndrome indicated that ophthalmic disorders were common. Cataracts were the most frequent ophthalmic disorder reported, followed by refractive errors, strabismus, and presbyopia. Severity of intellectual disability was unrelated to the presence of ophthalmic disorders. Also, ophthalmic disorders were associated with lower vision-dependent functional and cognitive abilities, although not to the extent that was expected. The high prevalence of ophthalmic disorders highlights the need for periodic evaluations and individualized treatment plans for adults with Down syndrome, in general, but especially when concerns are identified.

  1. Ophthalmic gels: Past, present and future.

    Science.gov (United States)

    Al-Kinani, Ali A; Zidan, Ghada; Elsaid, Naba; Seyfoddin, Ali; Alani, Adam W G; Alany, Raid G

    2018-02-15

    Aqueous gels formulated using hydrophilic polymers (hydrogels) along with those based on stimuli responsive polymers (in situ gelling or gel forming systems) continue to attract increasing interest for various eye health-related applications. They allow the incorporation of a variety of ophthalmic pharmaceuticals to achieve therapeutic levels of drugs and bioactives at target ocular sites. The integration of sophisticated drug delivery technologies such as nanotechnology-based ones with intelligent and environment responsive systems can extend current treatment duration to provide more clinically relevant time courses (weeks and months instead of hours and days) which will inevitably reduce dose frequency, increase patient compliance and improve clinical outcomes. Novel applications and design of contact lenses and intracanalicular delivery devices along with the move towards integrating gels into various drug delivery devices like intraocular pumps, injections and implants has the potential to reduce comorbidities caused by glaucoma, corneal keratopathy, cataract, diabetic retinopathies and age-related macular degeneration. This review describes ophthalmic gelling systems with emphasis on mechanism of gel formation and application in ophthalmology. It provides a critical appraisal of the techniques and methods used in the characterization of ophthalmic preformed gels and in situ gelling systems along with a thorough insight into the safety and biocompatibility of these systems. Newly developed ophthalmic gels, hydrogels, preformed gels and in situ gelling systems including the latest in the area of stimuli responsive gels, molecularly imprinted gels, nanogels, 3D printed hydrogels; 3D printed devices comprising ophthalmic gels are covered. Finally, new applications of gels in the production of artificial corneas, corneal wound healing and hydrogel contact lenses are described. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Medical Device Safety

    Science.gov (United States)

    A medical device is any product used to diagnose, cure, or treat a condition, or to prevent disease. They ... may need one in a hospital. To use medical devices safely Know how your device works. Keep ...

  3. Polymyxin B and Trimethoprim Ophthalmic

    Science.gov (United States)

    Polymyxin B and trimethoprim ophthalmic combination is used to treat bacterial infections of the eye including conjunctivitis (pinkeye; infection ... inside and outer parts of the eyelid). Polymyxin B and trimethoprim are in a class of medications ...

  4. Implantable electronic medical devices

    CERN Document Server

    Fitzpatrick, Dennis

    2014-01-01

    Implantable Electronic Medical Devices provides a thorough review of the application of implantable devices, illustrating the techniques currently being used together with overviews of the latest commercially available medical devices. This book provides an overview of the design of medical devices and is a reference on existing medical devices. The book groups devices with similar functionality into distinct chapters, looking at the latest design ideas and techniques in each area, including retinal implants, glucose biosensors, cochlear implants, pacemakers, electrical stimulation t

  5. Implantable Medical Devices

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Implantable Medical Devices Updated:Sep 16,2016 For Rhythm Control ... a Heart Attack Introduction Medications Surgical Procedures Implantable Medical Devices • Life After a Heart Attack • Heart Attack ...

  6. Treatment of neuro-ophthalmic sarcoidosis.

    Science.gov (United States)

    Frohman, Larry P

    2015-03-01

    Because of the rarity of neuro-ophthalmic sarcoidosis, there are no therapeutic guidelines based on evidence-based medicine for this disorder. Review of literature combined with personal experience. Corticosteroids are the preferred initial therapy for neuro-ophthalmic sarcoidosis. If patients cannot tolerate the requisite dose of corticosteroid needed to control their disease, or if corticosteroids fail to adequately control the disease process, the choices of a second agent are based on the consideration of rapidity of clinical response and the safety profile. Although methotrexate and mycophenolate mofetil are the medications that are often selected after corticosteroid failure, more rapidly acting agents that have been used are infliximab and intravenous cyclophosphamide.

  7. Financial return-on-investment of ophthalmic interventions: a new paradigm.

    Science.gov (United States)

    Brown, Melissa M; Brown, Gary C; Lieske, Heidi B; Lieske, P Alexander

    2014-05-01

    Although the patient value gain (improvement in quality-of-life and/or length-of-life) has been highlighted in Value-based Medicine cost-utility analyses, the financial value gain associated with healthcare interventions has received less emphasis. It is important for professional healthcare providers to realize their interventions often confer a large financial return-on-investment (ROI) to society. The societal costs associated with vitreoretinal and other ophthalmic interventions include: direct ophthalmic medical costs expended (hospital, physician, drug, diagnostic testing and so forth), direct medical costs saved (decreased costs for depression, injury, skilled nursing facility, nursing home and others), direct nonmedical costs saved (decreased costs for caregivers, transportation, residence costs, moving costs, and others), and indirect medical costs saved (improving employment incidence and wages). The financial ROI for direct ophthalmic medical costs expended for ranibizumab therapy for neovascular age-related macular degeneration is 450%, whereas that for cataract surgery is 4500% and for medical open-angle glaucoma therapy is 4000%. Many costs gained add to the Gross Domestic Product and increase the wealth of the nation. Many vitreoretinal and other ophthalmologic interventions confer considerable patient value, but also result in a large financial ROI to society. This financial ROI increases the wealth of the nation.

  8. Class 1 devices case studies in medical devices design

    CERN Document Server

    Ogrodnik, Peter J

    2014-01-01

    The Case Studies in Medical Devices Design series consists of practical, applied case studies relating to medical device design in industry. These titles complement Ogrodnik's Medical Device Design and will assist engineers with applying the theory in practice. The case studies presented directly relate to Class I, Class IIa, Class IIb and Class III medical devices. Designers and companies who wish to extend their knowledge in a specific discipline related to their respective class of operation will find any or all of these titles a great addition to their library. Class 1 Devices is a companion text to Medical Devices Design: Innovation from Concept to Market. The intention of this book, and its sister books in the series, is to support the concepts presented in Medical Devices Design through case studies. In the context of this book the case studies consider Class I (EU) and 510(k) exempt (FDA) . This book covers classifications, the conceptual and embodiment phase, plus design from idea to PDS. These title...

  9. Case outsourcing medical device reprocessing.

    Science.gov (United States)

    Haley, Deborah

    2004-04-01

    IN THE INTEREST OF SAVING MONEY, many hospitals are considering extending the life of some single-use medical devices by using medical device reprocessing programs. FACILITIES OFTEN LACK the resources required to meet the US Food and Drug Administration's tough quality assurance standards. BY OUTSOURCING, hospitals can reap the benefits of medical device reprocessing without assuming additional staffing and compliance burdens. OUTSOURCING enables hospitals to implement a medical device reprocessing program quickly, with no capital investment and minimal effort.

  10. Readability assessment of online ophthalmic patient information.

    Science.gov (United States)

    Edmunds, Matthew R; Barry, Robert J; Denniston, Alastair K

    2013-12-01

    Patients increasingly use the Internet to access information related to their disease, but poor health literacy is known to impact negatively on medical outcomes. Multiple agencies have recommended that patient-oriented literature be written at a fourth- to sixth-grade (9-12 years of age) reading level to assist understanding. The readability of online patient-oriented materials related to ophthalmic diagnoses is not yet known. To assess the readability of online literature specifically for a range of ophthalmic conditions. Body text of the top 10 patient-oriented websites for 16 different ophthalmic diagnoses, covering the full range of ophthalmic subspecialties, was analyzed for readability, source (United Kingdom vs non-United Kingdom, not for profit vs commercial), and appropriateness for sight-impaired readers. Four validated readability formulas were used: Flesch Reading Ease Score (FRES), Flesch-Kincaid Grade Level (FKGL), Simple Measure of Gobbledygook (SMOG), and Gunning Fog Index (GFOG). Data were compared with the Mann-Whitney test (for 2 groups) and Kruskal-Wallis test (for more than 2 groups) and correlation was assessed by the Spearman r. None of the 160 webpages had readability scores within published guidelines, with 83% assessed as being of "difficult" readability. Not-for-profit webpages were of significantly greater length than commercial webpages (P = .02) and UK-based webpages had slightly superior readability scores compared with those of non-UK webpages (P = .004 to P readability formula used). Of all webpages evaluated, only 34% included facility to adjust text size to assist visually impaired readers. To our knowledge, this is the first study to assess readability of patient-focused webpages specifically for a range of ophthalmic diagnoses. In keeping with previous studies in other medical conditions, we determined that readability scores were inferior to those recommended, irrespective of the measure used. Although readability is only one

  11. Diclofenac Ophthalmic

    Science.gov (United States)

    Diclofenac ophthalmic solution is used to treat eye pain, redness, and swelling in patients who are recovering ... treat clouding of the lens in the eye). Diclofenac ophthalmic solution is also used to temporarily relieve ...

  12. Medical device-related pressure ulcers

    Directory of Open Access Journals (Sweden)

    Black JM

    2016-08-01

    Full Text Available Joyce M Black,1 Peggy Kalowes2 1Adult Health and Illness Department, College of Nursing, University of Nebraska Medical Center, Omaha, NE, 2Nursing Research and Innovation, Long Beach Memorial Miller Children’s & Women’s Hospital, Long Beach, CA, USA Abstract: Pressure ulcers from medical devices are common and can cause significant morbidity in patients of all ages. These pressure ulcers appear in the shape of the device and are most often found from the use of oxygen delivery devices. A hospital program designed to reduce the number of pressure ulcers from medical devices was successful. The program involved the development of a team that focused on skin, the results were then published for the staff to track their performance, and it was found that using foam dressings helped reduce the pressure from the device. The incidence of ulcers from medical devices has remained at zero at this hospital since this program was implemented. Keywords: pressure ulcer, medical device related

  13. Are ultrasound-guided ophthalmic blocks injurious to the eye? A comparative rabbit model study of two ultrasound devices evaluating intraorbital thermal and structural changes.

    Science.gov (United States)

    Palte, Howard D; Gayer, Steven; Arrieta, Esdras; Scot Shaw, Eric; Nose, Izuru; Lee, Elizabete; Arheart, Kristopher L; Dubovy, Sander; Birnbach, David J; Parel, Jean-Marie

    2012-07-01

    Since Atkinson's original description of retrobulbar block in 1936, needle-based anesthetic techniques have become integral to ophthalmic anesthesia. These techniques are unfortunately associated with rare, grave complications such as globe perforation. Ultrasound has gained widespread acceptance for peripheral nerve blockade, but its translation to ocular anesthesia has been hampered because sonic energy, in the guise of thermal or biomechanical insult, is potentially injurious to vulnerable eye tissue. The US Food and Drug Administration (FDA) has defined guidelines for safe use of ultrasound for ophthalmic examination, but most ultrasound devices used by anesthesiologists are not FDA-approved for ocular application because they generate excessive energy. Regulating agencies state that ultrasound examinations can be safely undertaken as long as tissue temperatures do not increase >1.5°C above physiological levels. Using a rabbit model, we investigated the thermal and mechanical ocular effects after prolonged ultrasonic exposure to single orbital- and nonorbital-rated devices. In a dual-phase study, aimed at detecting ocular injury, the eyes of 8 rabbits were exposed to continuous 10-minute ultrasound examinations from 2 devices: (1) the Sonosite Micromaxx (nonorbital rated) and (2) the Sonomed VuMax (orbital rated) machines. In phase I, temperatures were continuously monitored via thermocouples implanted within specific eye structures (n = 4). In phase II the eyes were subjected to ultrasonic exposure without surgical intervention (n = 4). All eyes underwent light microscopy examinations, followed at different intervals by histology evaluations conducted by an ophthalmic pathologist. Temperature changes were monitored in the eyes of 4 rabbits. The nonorbital-rated transducer produced increases in ocular tissue temperature that surpassed the safe limit (increases >1.5°C) in the lens of 3 rabbits (at 5.0, 5.5, and 1.5 minutes) and cornea of 2 rabbits (both at 1

  14. Human Factors and Medical Devices

    International Nuclear Information System (INIS)

    Dick Sawyer

    1998-01-01

    Medical device hardware- and software-driven user interfaces should be designed to minimize the likelihood of use-related errors and their consequences. The role of design-induced errors in medical device incidents is attracting widespread attention. The U.S. Food and Drug Administration (FDA) is fully cognizant that human factors engineering is critical to the design of safe medical devices, and user interface design is receiving substantial attention by the agency. Companies are paying more attention to the impact of device design, including user instructions, upon the performance of those health professionals and lay users who operate medical devices. Concurrently, the FDA is monitoring human factors issues in its site inspections, premarket device approvals, and postmarket incident evaluations. Overall, the outlook for improved designs and safer device operation is bright

  15. An international strategic plan to preserve and restore vision: four curricula of ophthalmic education.

    Science.gov (United States)

    Tso, Mark O M; Goldberg, Morton F; Lee, Andrew G; Selvarajah, Sivaguru; Parrish, Richard K; Zagorski, Zbigniew

    2007-05-01

    To highlight the four International Curricula of Ophthalmic Education developed by the Task Forces of the International Council of Ophthalmology, published in Klinische Monatsblätter für Augenheilkunde in November 2006. A global perspective of developing educational curricula as tools to improve eye care. Review of the experience and conclusions of the four international panels. The Task Force on Resident and Specialist Education developed a curriculum consisting of 15 topics in basic, standard, and advanced levels to provide flexibility of educational programs of the ophthalmic specialist in different locations across the world. The curricula were designed to be an educational tool to stimulate multiple levels of training of the ophthalmic specialist. The Task Force on Ophthalmic Education of Medical Students designed a curriculum covering 11 topics and provides illustrative materials for teachers and students. The Task Force strongly advocates the ophthalmology curriculum to be part of the core program of general medical schools education. The Task Force on Para-ophthalmic Vision Specialist Education developed a curriculum to highlight the importance of a team approach to eye care, consisting of ophthalmic specialists and paraophthalmic personnel to produce maximum efficiency. The Task Force on Continuing Medical Education (CME) designed a curriculum exploring the principles, elements, categories, and administration of CME activities in a variety of topics. These curricula shifted the traditional apprentice system of education to a curriculum-based training program in which goals, expectations, competencies, and technical training are defined to improve eye care worldwide.

  16. [Medical Devices Law for pain therapists].

    Science.gov (United States)

    Regner, M; Sabatowski, R

    2016-08-01

    Medical Devices Law is a relatively new legal system, which has replaced the Medical Devices Regulations still well-known in Germany. German Medical Devices Law is based on European directives, which are, in turn, incorporated into national law by the Medical Devices Act. The Medical Devices Act is a framework law and covers a number of regulations that address specific topics within Medical Devices Law. In turn, in individual regulations, reference is made to guidelines, recommendations, etc. from other sources that provide detailed technical information on specific topics. Medical Devices Law is a very complex legal system, which needs to be permanently observed due to constant updating and adjustment. In the current article, the design and the structure of the system will be described, but special emphasis will be laid on important problem areas that need to be considered when applying and operating medical products, in this case by pain therapists in particular.

  17. Basics of Sterile Compounding: Ophthalmic Preparations, Part 1: Ophthalmic Solutions.

    Science.gov (United States)

    Allen, Loyd V

    2016-01-01

    Ophthalmic preparations are used to treat allergies, bacterial and viral infections, glaucoma, and numerous other eye conditions. When the eye's natural defensive mechanisms are compromised or overcome, an ophthalmic preparation, in a solution, suspension, or ointment form, may be indicated, with solutions being the most common form used to deliver a drug to the eye. This article provides a general discussion on ophthalmic preparations and specifically discusses the preparation of solutions. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  18. Postoperative pain in complex ophthalmic surgical procedures: comparing practice with guidelines.

    Science.gov (United States)

    Lesin, Mladen; Sundov, Zeljka Duplancic; Jukic, Marko; Puljak, Livia

    2014-06-01

    To analyze the management of postoperative pain after complex ophthalmic surgery and to compare it to the guidelines. A retrospective study. University Hospital Split, Croatia. Patients (N = 447) who underwent complex ophthalmic surgical procedures from 2008 to 2012. The following data were extracted from patient medical records: age, gender, type and dosage of premedication, preoperative patient's physical status, type of procedure, duration of procedure-surgical and anesthesia time, type and dosage of anesthesia, the type and dosage of postoperative analgesia for each postoperative day. None of the patients had information about pain intensity in their records. There were 90% patients who did not receive any medication the night before surgery, 54% did not receive any premedication immediately before surgery, 19% did not receive any pain medication after the surgery in the operating room and 46% of patients did not receive any analgesics after being released to the ophthalmology department. Among those who received analgesia after surgery, 98% received only one dose of an analgesic, and 93% of patients received analgesia only on the day of the surgery. Furthermore, patients were returned to the department immediately after surgery, without intensive monitoring. During the analyzed five years there were no educational session organized by anesthesiologist to the ophthalmic surgeons. Postoperative pain management and perioperative care of patients undergoing major ophthalmic surgery indicates lack of attention towards pain intensity and postoperative analgesia. Appropriate interventions should be employed to improve postoperative pain management, to facilitate patient recovery. Wiley Periodicals, Inc.

  19. Medical device software: defining key terms.

    Science.gov (United States)

    Pashkov, Vitalii; Gutorova, Nataliya; Harkusha, Andrii

    one of the areas of significant growth in medical devices has been the role of software - as an integral component of a medical device, as a standalone device and more recently as applications on mobile devices. The risk related to a malfunction of the standalone software used within healthcare is in itself not a criterion for its qualification or not as a medical device. It is therefore, necessary to clarify some criteria for the qualification of stand-alone software as medical devices Materials and methods: Ukrainian, European Union, United States of America legislation, Guidelines developed by European Commission and Food and Drug Administration's, recommendations represented by international voluntary group and scientific works. This article is based on dialectical, comparative, analytic, synthetic and comprehensive research methods. the legal regulation of software which is used for medical purpose in Ukraine limited to one definition. In European Union and United States of America were developed and applying special guidelines that help developers, manufactures and end users to difference software on types standing on medical purpose criteria. Software becomes more and more incorporated into medical devices. Developers and manufacturers may not have initially appreciated potential risks to patients and users such situation could have dangerous results for patients or users. It is necessary to develop and adopt the legislation that will intend to define the criteria for the qualification of medical device software and the application of the classification criteria to such software, provide some illustrative examples and step by step recommendations to qualify software as medical device.

  20. Subspecialization of the ophthalmic literature: a review of the publishing trends of the top general, clinical ophthalmic journals.

    Science.gov (United States)

    Kumar, Anupma; Cheeseman, Robert; Durnian, Jonathan M

    2011-06-01

    To investigate the publishing trends of the top general clinical ophthalmic journals and to report: (1) the proportions of articles published in terms of ophthalmic subspecialty, (2) the study design used, (3) any changes in publishing trends, and (4) any differences in the quality of study design between the subspecialties. Retrospective, database review. All original articles published in the top general, clinical ophthalmology journals from 2005 through 2009. All general, clinical ophthalmic journals were selected from the top 20 journals based on 2008 impact factor. All abstracts from original articles were reviewed, and the subject matter was recorded as belonging to 1 of the 11 ophthalmic subspecialties. After the content of the article was assigned, then the study design was recorded as one of the following: nonanalytic study, case-control or cohort study, randomized control trial, meta-analysis, laboratory science article, or systemic review. Subspecialty of the article and the study design used. Seven journals were included, and 12 426 abstracts were reviewed. Articles relating to medical retina were the most prevalent (29.1%), and those relating to strabismus were the least prevalent (2.3%). Case-control or cohort studies comprised most study designs (40.1%), with meta-analyses comprising the least (0.3%). The mean number of articles per year was 2485 (standard deviation, 125.1), remaining stable over the study period. Medical retina articles were significantly more common in 2009 than in 2005 (chi-square, 11.2; P = 0.0008), whereas the proportion of oculoplastic articles was significantly reduced (chi-square, 16.9; P<0.0001). Cataract and refractive surgery had the highest proportions of articles using the higher forms of study design (7.8%), and oculoplastics had the highest proportion of nonanalytic studies (64.5%). There are great differences across the specialty of ophthalmology in the subject matter of published literature, probably driven by recent

  1. Medical devices regulations, standards and practices

    CERN Document Server

    Ramakrishna, Seeram; Wang, Charlene

    2015-01-01

    Medical Devices and Regulations: Standards and Practices will shed light on the importance of regulations and standards among all stakeholders, bioengineering designers, biomaterial scientists and researchers to enable development of future medical devices. Based on the authors' practical experience, this book provides a concise, practical guide on key issues and processes in developing new medical devices to meet international regulatory requirements and standards. Provides readers with a global perspective on medical device regulationsConcise and comprehensive information on how to desig

  2. 21 CFR 892.2040 - Medical image hardcopy device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical image hardcopy device. 892.2040 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2040 Medical image hardcopy device. (a) Identification. A medical image hardcopy device is a device that produces a visible printed record of a medical...

  3. [Consideration of Mobile Medical Device Regulation].

    Science.gov (United States)

    Peng, Liang; Yang, Pengfei; He, Weigang

    2015-07-01

    The regulation of mobile medical devices is one of the hot topics in the industry now. The definition, regulation scope and requirements, potential risks of mobile medical devices were analyzed and discussed based on mobile computing techniques and the FDA guidance of mobile medical applications. The regulation work of mobile medical devices in China needs to adopt the risk-based method.

  4. Surgical tools and medical devices

    CERN Document Server

    Jackson, Mark

    2016-01-01

    This new edition presents information and knowledge on the field of biomedical devices and surgical tools. The authors look at the interactions between nanotechnology, nanomaterials, design, modeling, and tools for surgical and dental applications, as well as how nanostructured surfaces can be created for the purposes of improving cell adhesion between medical devices and the human body. Each original chapter is revised in this second edition and describes developments in coatings for heart valves, stents, hip and knee joints, cardiovascular devices, orthodontic applications, and regenerative materials such as bone substitutes. There are also 8 new chapters that address: Microvascular anastomoses Inhaler devices used for pulmonary delivery of medical aerosols Surface modification of interference screws Biomechanics of the mandible (a detailed case study) Safety and medical devices The synthesis of nanostructured material Delivery of anticancer molecules using carbon nanotubes Nano and micro coatings for medic...

  5. Medical device development.

    Science.gov (United States)

    Panescu, Dorin

    2009-01-01

    The development of a successful medical product requires not only engineering design efforts, but also clinical, regulatory, marketing and business expertise. This paper reviews items related to the process of designing medical devices. It discusses the steps required to take a medical product idea from concept, through development, verification and validation, regulatory approvals and market release.

  6. Digital video recording and archiving in ophthalmic surgery

    Directory of Open Access Journals (Sweden)

    Raju Biju

    2006-01-01

    Full Text Available Currently most ophthalmic operating rooms are equipped with an analog video recording system [analog Charge Couple Device camera for video grabbing and a Video Cassette Recorder for recording]. We discuss the various advantages of a digital video capture device, its archiving capabilities and our experience during the transition from analog to digital video recording and archiving. The basic terminology and concepts related to analog and digital video, along with the choice of hardware, software and formats for archiving are discussed.

  7. Radiation sterilization of medical products- current trends and future prospects

    International Nuclear Information System (INIS)

    Sharma, G.

    1997-01-01

    In medical practice use of sterile pharmaceuticals and single use disposable medical devices is steadily increasing. Sterile pharmaceuticals like injections and ophthalmic ointments are required for therapy. Medical devices are employed for diagnostic, drug administration or corrective purposes, and as implants for temporary, short term or long term residence in the human system. All these products are made available in sterile form by treating them to a suitable process of sterilization i.e. dry/wet heat, ethylene oxide (EtO) gas or ionizing radiation. In this paper current trends and future prospects of radiation sterilization of medical products are given in detail. 9 refs., 7 tabs

  8. International Standards for Radiation Sterilization of Medical Devices

    International Nuclear Information System (INIS)

    Miller, A.

    2007-01-01

    For a terminally sterilized medical device to be designated '' STERILE '', probability of finding the viable micro-organisms in the device shall be equal to or less than 1 x 10 -6 (EN 556-1:2001: Sterilization of medical devices - Requirements for medical devices to be designated '' STERILE '' - Part 1: Requirements for terminally sterilized medical devices). Author presents the main legal aspects of the international standards for radiation sterilization of medical devices

  9. Noninvasive Dry Eye Assessment Using High-Technology Ophthalmic Examination Devices.

    Science.gov (United States)

    Yamaguchi, Masahiko; Sakane, Yuri; Kamao, Tomoyuki; Zheng, Xiaodong; Goto, Tomoko; Shiraishi, Atsushi; Ohashi, Yuichi

    2016-11-01

    Recently, the number of dry eye cases has dramatically increased. Thus, it is important that easy screening, exact diagnoses, and suitable treatments be available. We developed 3 original and noninvasive assessments for this disorder. First, a DR-1 dry eye monitor was used to determine the tear meniscus height quantitatively by capturing a tear meniscus digital image that was analyzed by Meniscus Processor software. The DR-1 meniscus height value significantly correlated with the fluorescein meniscus height (r = 0.06, Bland-Altman analysis). At a cutoff value of 0.22 mm, sensitivity of the dry eye diagnosis was 84.1% with 90.9% specificity. Second, the Tear Stability Analysis System was used to quantitatively measure tear film stability using a topographic modeling system corneal shape analysis device. Tear film stability was objectively and quantitatively evaluated every second during sustained eye openings. The Tear Stability Analysis System is currently installed in an RT-7000 autorefractometer and topographer to automate the diagnosis of dry eye. Third, the Ocular Surface Thermographer uses ophthalmic thermography for diagnosis. The decrease in ocular surface temperature in dry eyes was significantly greater than that in normal eyes (P eye opening. Decreased corneal temperature correlated significantly with the tear film breakup time (r = 0.572; P dry eye, sensitivity was 0.83 and specificity was 0.80 after 10 seconds. This article describes the details and potential of these 3 noninvasive dry eye assessment systems.

  10. Audit of patients' awareness of ophthalmic diagnoses.

    Science.gov (United States)

    Sudesh, S; Downes, S M; McDonnell, P J

    1993-09-01

    Providing information to patients about their medical condition and treatment options is important in medical management. To assess patients' knowledge of their ocular disease, prognosis, and treatment a questionnaire based survey was performed. 219 patients selected by random systematic sampling during six months from patients attending general ophthalmic clinics in Selly Oak Hospital, Birmingham, were questioned and 217 questionnaires were analysed. The findings showed that patients' knowledge of their diagnosis depended on their condition: patients with common conditions such as glaucoma and cataract had a better understanding of their condition, its treatment, and prognosis compared with patients with rarer conditions such as retinal detachment or patients with multiple diagnoses. In all, 152 patients (70%) wanted more information about their condition; 49 (23%) did not (although 12 (25%) had attempted to obtain information); and 16 (7%) were undecided. In view of the few patients with a precise understanding of their ophthalmic diagnosis and prognosis and the majority's wish for access to further information, that access needs improvement and different modes of disseminating the information should be implemented.

  11. 75 FR 54492 - Ophthalmic and Topical Dosage Form New Animal Drugs; Gentamicin and Betamethasone Ophthalmic...

    Science.gov (United States)

    2010-09-08

    ... Ophthalmic Solution AGENCY: Food and Drug Administration, HHS. ACTION: Final rule; technical amendment... acetate ophthalmic solution. This action is being taken to comply with the Federal Food, Drug, and... GENTOCIN DURAFILM (gentamicin sulfate and betamethasone acetate) Ophthalmic Solution, sponsored by Intervet...

  12. The international council of ophthalmology: vision for ophthalmic education in an interdependent world.

    Science.gov (United States)

    Lee, Andrew G; Golnik, Karl C; Tso, Mark O M; Spivey, Bruce; Miller, Kathleen; Gauthier, Tina-Marie

    2012-10-01

    To describe the emerging strategic global perspective of the International Council of Ophthalmology (ICO) efforts in ophthalmic education. A global perspective describing how the development of sophisticated educational tools in tandem with information technology can revolutionize ophthalmic education worldwide. Review of ICO educational tools, resources, and programs that are available to ophthalmic educators across the globe. With the explosive growth of the Internet, the ability to access medical information in the most isolated of locations is now possible. Through specific ICO initiatives, including the ICO curricula, the "Teaching the Teachers" program, and the launching of the new ICO Center for Ophthalmic Educators, the ICO is providing ophthalmic educators across the globe with access to standardized but customizable educational programs and tools to better train ophthalmologists and allied eye care professionals throughout the world. Access to educational tools and strengthening of global learning will help providers meet the goals of VISION 2020 and beyond in eliminating avoidable blindness. It is the intent of the ICO that its programs for ophthalmic educators, including conferences, courses, curricula, and online resources, result in better-trained ophthalmologists and eye care professionals worldwide. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Ophthalmic patients' utilization of technology and social media: an assessment to improve quality of care.

    Science.gov (United States)

    Aleo, Chelsea L; Hark, Lisa; Leiby, Benjamin; Dai, Yang; Murchison, Ann P; Martinez, Patricia; Haller, Julia A

    2014-10-01

    E-health tools have the potential to improve the quality of care for ophthalmic patients, many of whom have chronic conditions. However, little research has assessed ophthalmic patients' use or acceptance of technological devices and social media platforms for health-related purposes. The present study evaluated utilization of technological devices and social media platforms by eye clinic patients, as well as their willingness to receive health reminders through these technologies. A 31-item paper questionnaire was administered to eye clinic patients (n=843) at an urban, tertiary-care center. Questions focused on technology ownership, comfort levels, frequency of use, and preferences for receiving health reminders. Demographic data were also recorded. Eye clinic patients most commonly owned cellular phones (90%), landline phones (81%), and computers (80%). Overall, eye clinic patients preferred to receive health reminders through phone calls and e-mail and used these technologies frequently and with a high level of comfort. Less than 3% of patients preferred using social networking to receive health reminders. In addition, age was significantly associated with technology ownership, comfort level, and frequency of use (ptechnologies more frequently and with a higher comfort level (ptechnologies for appointment reminders, general eye and vision health information, asking urgent medical questions, and requesting prescription refills. Future controlled trials could further explore the efficacy of e-health tools for these purposes.

  14. Body Implanted Medical Device Communications

    Science.gov (United States)

    Yazdandoost, Kamya Yekeh; Kohno, Ryuji

    The medical care day by day and more and more is associated with and reliant upon concepts and advances of electronics and electromagnetics. Numerous medical devices are implanted in the body for medical use. Tissue implanted devices are of great interest for wireless medical applications due to the promising of different clinical usage to promote a patient independence. It can be used in hospitals, health care facilities and home to transmit patient measurement data, such as pulse and respiration rates to a nearby receiver, permitting greater patient mobility and increased comfort. As this service permits remote monitoring of several patients simultaneously it could also potentially decrease health care costs. Advancement in radio frequency communications and miniaturization of bioelectronics are supporting medical implant applications. A central component of wireless implanted device is an antenna and there are several issues to consider when designing an in-body antenna, including power consumption, size, frequency, biocompatibility and the unique RF transmission challenges posed by the human body. The radiation characteristics of such devices are important in terms of both safety and performance. The implanted antenna and human body as a medium for wireless communication are discussed over Medical Implant Communications Service (MICS) band in the frequency range of 402-405MHz.

  15. Medical Devices

    NARCIS (Netherlands)

    Verkerke, Gijsbertus Jacob; Mahieu, H.F.; Geertsema, A.A.; Hermann, I.F.; van Horn, J.R.; Hummel, J. Marjan; van Loon, J.P.; Mihaylov, D.; van der Plaats, A.; Schraffordt Koops, H.; Schutte, H.K.; Veth, R.P.H.; de Vries, M.P.; Rakhorst, G.; Shi, Donglu

    2004-01-01

    The development of new medical devices is a very time-consuming and costly process. Besides the time between the initial idea and the time that manufacturing and testing of prototypes takes place, the time needed for the development of production facilities, production of test series, marketing,

  16. Classification and evaluation of medical devices

    Directory of Open Access Journals (Sweden)

    Edina Vranić

    2003-05-01

    Full Text Available Medical devices and medical disposables contribute significantly to the quality and effectiveness of the health care system. It is necessary to commit scientifically sound regulatory environment that will provide consumers with the best medical care. This includes continued services to small manufacturers, readily available guidance on FDA requirements, predictable and reasonable response times on applications for marketing, and equitable enforcement. But in the public interest, this commitment to the industry must be coupled with a reciprocal commitment: that medical device firms will meet high standards in the design, manufacture, and evaluation of their products. The protections afforded our consumer, and the benefits provided the medical device industry, cannot be underestimated.

  17. Radioactivity measurements for some ophthalmic glasses

    International Nuclear Information System (INIS)

    Badawy, W.M.; Ali, E.M.; Gomaa, M.A.; Hussein, A

    2007-01-01

    The main aim of the present work is to implant the latest ICRP/IAEA recommendations related to exemption and clearness to the Ophthalmic Glass. As consumer product, glass lenses may contain trace quantities of uranium, thorium and potassium. Glass lenses under investigation were monitored for the detection of gamma rays and beta particles using radiation measuring devices. Using high purity germanium detector radioactivity concentration was estimated in Bq/kg. Activity concentration of 226 Ra, Th-232 and K-40 were determined using the energy gamma lines of 2l4 Pb (352 keV), 212 Pb (238 keV) and 1460 keV gamma line for 40 K respectively .Experimental results showed that radioactivity concentration for radium -226 varies from 0.19 to 4.98 Bq/kg of radium-226, from to 0.18 to 2.83 Bq/kg for thorium -232 and from 0.8 to 1.13 Bq/kg for potassium. Implementing new ICRP recommendation of exemption and clearness indicated that several Ophthalmic Glass should not be in use

  18. Contextual inquiry for medical device design

    CERN Document Server

    Privitera, Mary Beth

    2015-01-01

    Contextual Inquiry for Medical Device Design helps users understand the everyday use of medical devices and the way their usage supports the development of better products and increased market acceptance. The text explains the concept of contextual inquiry using real-life examples to illustrate its application. Case studies provide a frame of reference on how contextual inquiry is successfully used during product design, ultimately producing safer, improved medical devices. Presents the ways contextual inquiry can be used to inform the evaluation and business case of technologyHelps users

  19. Medical device market in China.

    Science.gov (United States)

    Boyer, Philip; Morshed, Bashir I; Mussivand, Tofy

    2015-06-01

    With China's growing old-age population and economic presence on the international stage, it has become important to evaluate its domestic and foreign market contribution to medical devices. Medical devices are instruments or apparatuses used in the prevention, rehabilitation, treatment, or knowledge generation with respect to disease or other abnormal conditions. This article provides information drawn from recent publications to describe the current state of the Chinese domestic market for medical devices and to define opportunities for foreign investment potential therein. Recent healthcare reforms implemented to meet rising demand due to an aging and migrating population are having a positive effect on market growth-a global market with a projected growth of 15% per year over the next decade. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Ophthalmic regional blocks: management, challenges, and solutions

    Directory of Open Access Journals (Sweden)

    Palte HD

    2015-08-01

    Full Text Available Howard D Palte Department of Anesthesiology, Perioperative Medicine and Pain Management, Miller School of Medicine, University of Miami, Miami, FL, USA Abstract: In the past decade ophthalmic anesthesia has witnessed a major transformation. The sun has set on the landscape of ophthalmic procedures performed under general anesthesia at in-hospital settings. In its place a new dawn has ushered in the panorama of eye surgeries conducted under regional and topical anesthesia at specialty eye care centers. The impact of the burgeoning geriatric population is that an increasing number of elderly patients will present for eye surgery. In order to accommodate increased patient volumes and simultaneously satisfy administrative initiatives directed at economic frugality, administrators will seek assistance from anesthesia providers in adopting measures that enhance operating room efficiency. The performance of eye blocks in a holding suite meets many of these objectives. Unfortunately, most practicing anesthesiologists resist performing ophthalmic regional blocks because they lack formal training. In future, anesthesiologists will need to block eyes and manage common medical conditions because economic pressures will eliminate routine preoperative testing. This review addresses a variety of topical issues in ophthalmic anesthesia with special emphasis on cannula and needle-based blocks and the new-generation antithrombotic agents. In a constantly evolving arena, the sub-Tenon’s block has gained popularity while the deep angulated intraconal (retrobulbar block has been largely superseded by the shallower extraconal (peribulbar approach. Improvements in surgical technique have also impacted anesthetic practice. For example, phacoemulsification techniques facilitate the conduct of cataract surgery under topical anesthesia, and suture-free vitrectomy ports may cause venous air embolism during air/fluid exchange. Hyaluronidase is a useful adjuvant because it

  1. Safety, efficacy, and intraoperative characteristics of DisCoVisc and Healon ophthalmic viscosurgical devices for cataract surgery

    Directory of Open Access Journals (Sweden)

    Modi SS

    2011-09-01

    Full Text Available Satish S Modi1, James A Davison2, Tom Walters3 1Seeta Eye Centers, Poughkeepsie, NY, USA; 2Wolfe Clinic, Marshalltown, IA, USA; 3Texas Eye Care, Austin, TX, USA Purpose: To evaluate the safety and efficacy of DisCoVisc ophthalmic viscosurgical device (OVD, Alcon Laboratories, Inc with respect to a comparator, Healon OVD (Advanced Medical Optics, Inc. Patients and methods: In this prospective study, patients with cataracts were randomized to an OVD, and then received phacoemulsification and injection of an intraocular lens. After each surgery, unmasked investigators completed subjective questionnaires about OVD characteristics during each stage of the procedure. Masked technicians evaluated objective safety parameters of intraocular pressure (IOP and endothelial cell density, with 90 days of follow-up. Results: The DisCoVisc OVD group (128 eyes and the Healon OVD group (121 eyes had statistically similar outcomes for IOP and for endothelial cell loss. Subjectively assessed viscosity was statistically different (P < 0.0001, with Healon OVD most often rated “cohesive” and DisCoVisc OVD most often rated “both dispersive and cohesive”. Workspace maintenance differed between groups (P < 0.0001, with workspace most frequently rated “full chamber maintained” when using DisCoVisc OVD and most frequently rated “workspace maintained” when using Healon OVD. “Flat” or “shallow” workspace ratings occurred only in the Healon OVD group. Conclusion: DisCoVisc OVD had both cohesive and dispersive properties, and was safe and effective for every stage of cataract surgery. Keywords: cataract, endothelial cell density, viscoelastic, phacoemulsification

  2. International Council of Ophthalmology: Refocusing Ophthalmic Education in the Asia-Pacific Region and Beyond.

    Science.gov (United States)

    Golnik, Karl; Mayorga, Eduardo; Spivey, Bruce; Ritch, Robert; Gauthier, Tina-Marie

    2012-01-01

    The International Council of Ophthalmology (ICO) is a global organization with a regional focus. Working in partnership with supranational and ICO member societies, the ICO is building a "World Alliance for Sight" to improve access to the highest-quality eye care worldwide. Designed to preserve and restore vision on an international scale, the ICO initiative, "Refocusing Ophthalmic Education," enhances ophthalmic education of residents, subspecialists, medical students, and allied eye care personnel by redefining the most effective ways to teach and in creating beneficial educational opportunities. The "Teaching the Teachers" program helps ophthalmic educators incorporate more effective methods of training and continuing professional development to meet societal needs, achieved in part through regional courses for residency program directors; symposia, and keynote talks presented by ICO's World Ophthalmology Educational Colloquium, Conferences for Ophthalmic Educators, and ophthalmic surgical competency rubrics. Recognizing that standardized curricula are essential for consistent ophthalmic education, the ICO has developed a curricular framework whereby goals, expectations, knowledge base, competencies, and technical training are delineated. The ICO is defining worldwide models of team training and compiling best practice, which will include training-program accreditation to ensure improvement in the education of ophthalmologists. International Council of Ophthalmology Web-based teaching courses, a Webinar Network, and a technology blog further support information and communication technologies for teaching and learning. At the ICO's Center for Ophthalmic Educators (educators.icoph.org), trainers will find valuable teaching resources in multiple languages as well as ways to share ideas and collaborate with peers and other ophthalmic educators.

  3. Legislative aspects of the development of medical devices.

    Science.gov (United States)

    Marešová, Petra; Klímová, Blanka; Krejcar, Ondřej; Kuča, Kamil

    2015-09-01

    European industry of medical device technologies represents 30% of all worlds sales. New health technologies bring effective treatment approaches, help shorten stays in hospital1),bring better treatment results and accelerate rehabilitation which leads to the earlier patients recovery.Legislative aspects are one of the key areas influencing the speed of development of medical devices and their launching. The aim of this article is to specify current state of legislation in the development of medical devices in the European Union in comparison with the market leaders such as China, Japan and USA.The best established market of medical devices is in the USA. Both Japan and China follow the USA model. However, a non-professional code of ethics in China in some respect contributes to the decrease of quality of medical devices, while Japan as well as the EU countries try really hard to conform to all the regulations imposed on the manufacturing of medical devices.

  4. Mobile medical device connectivity: real world solutions.

    Science.gov (United States)

    Pettus, Dan

    2004-01-01

    Mobile medical devices, such as infusion pumps, provide an important therapeutic function. They are also valuable sources of information about treatment patterns at the point of care. However, these mobile devices have been independent islands of valuable information, unable to share the data they gather with other hospital information resources on a real time basis. Although data from these devices can provide significant improvements for medical safety and vital information needed for clinical best practice development, gathering that data poses significant challenges when interfacing with hospital information systems. Mobile medical devices move from place to place as independent actors, raising a series of security and identification issues when they need to be disconnected and reconnected using traditional tethered cable connections. The continuing lack of accepted communications protocol standards, in spite of the concentrated efforts of organizations like the IEEE and the Medical Information Bus (IEEE 1073) to establish them, has made integration into the hospital information system a complex and non-standard task. The rapid spread in availability and adoption of high-speed 802.11 wireless systems in hospitals offers a realistic connectivity solution for mobile medical devices. Inspite of this, the 802.11 standard is still evolving, and current security methods designed for user-based products like PDAs and laptop computers are not ideal for unmanned mobile medical devices because they assume the availability of a human operator to authenticate a wireless session. In the absence of accepted standards, manufacturers have created practical and innovative solutions to support the collection of clinical data from mobile medical devices and the integration of that data with hospital information systems. This paper will explore the potential benefits of integrating mobile medical devices into the hospital information system, and describe the challenges in

  5. Analytical Chemistry in the Regulatory Science of Medical Devices.

    Science.gov (United States)

    Wang, Yi; Guan, Allan; Wickramasekara, Samanthi; Phillips, K Scott

    2018-06-12

    In the United States, regulatory science is the science of developing new tools, standards, and approaches to assess the safety, efficacy, quality, and performance of all Food and Drug Administration-regulated products. Good regulatory science facilitates consumer access to innovative medical devices that are safe and effective throughout the Total Product Life Cycle (TPLC). Because the need to measure things is fundamental to the regulatory science of medical devices, analytical chemistry plays an important role, contributing to medical device technology in two ways: It can be an integral part of an innovative medical device (e.g., diagnostic devices), and it can be used to support medical device development throughout the TPLC. In this review, we focus on analytical chemistry as a tool for the regulatory science of medical devices. We highlight recent progress in companion diagnostics, medical devices on chips for preclinical testing, mass spectrometry for postmarket monitoring, and detection/characterization of bacterial biofilm to prevent infections.

  6. Management of ocular inflammation and pain following cataract surgery: focus on bromfenac ophthalmic solution

    OpenAIRE

    Cho, Hyung; Wolf, Kenneth J; Wolf, Eric J

    2009-01-01

    Hyung Cho1, Kenneth J Wolf1, Eric J Wolf21Department of Ophthalmology, Albert Einstein College of Medicine, Montefiore Medical Center, Bronx, New York, USA; 2Department of Ophthalmology, Edward S. Harkness Eye Institute of Columbia University College of Physicians and Surgeons, New York, NY, USAAbstract: Recently, several new ophthalmic NSAID products have been introduced for commercial use in the United States. The purpose of this review is to briefly overview the ophthalmic NSAIDs currently...

  7. Ophthalmic examination in early diagnosis of Alzheimer's disease

    Directory of Open Access Journals (Sweden)

    Xin Li

    2018-02-01

    Full Text Available Alzheimer's disease is a progressive neurodegenerative disorder causing irreversible deterioration in memory and loss of self-care ability, which is seriously affecting the quality of life. There is no cure for Alzheimer's disease. Medication only can control the progression of the disease. Early diagnosis and control of disease progress is of great significance in improving the quality of life of the patients and reducing the burden of family and society. Ophthalmic examination is seen as a window which can “see” brain directly, and some changes in the eye can reflect the changes of the brain most directly. This paper reviews the ophthalmic examination of Alzheimer's disease, including optical coherence tomography(OCT, visual field, contrast sensitivity and eye movements, et al. We hope to provide a new idea for the early diagnosis of Alzheimer's disease.

  8. An update on mobile phones interference with medical devices.

    Science.gov (United States)

    Mahmoud Pashazadeh, Ali; Aghajani, Mahdi; Nabipour, Iraj; Assadi, Majid

    2013-10-01

    Mobile phones' electromagnetic interference with medical devices is an important issue for the medical safety of patients who are using life-supporting medical devices. This review mainly focuses on mobile phones' interference with implanted medical devices and with medical equipment located in critical areas of hospitals. A close look at the findings reveals that mobile phones may adversely affect the functioning of medical devices, and the specific effect and the degree of interference depend on the applied technology and the separation distance. According to the studies' findings and the authors' recommendations, besides mitigating interference, using mobile phones at a reasonable distance from medical devices and developing technology standards can lead to their effective use in hospital communication systems.

  9. An update on mobile phones interference with medical devices

    International Nuclear Information System (INIS)

    Pashazadeh, A. M.; Aghajani, M.; Nabipour, I.; Assadi, M.

    2013-01-01

    Mobile phones' electromagnetic interference with medical devices is an important issue for the medical safety of patients who are using life-supporting medical devices. This review mainly focuses on mobile phones' interference with implanted medical devices and with medical equipment located in critical areas of hospitals. A close look at the findings reveals that mobile phones may adversely affect the functioning of medical devices, and the specific effect and the degree of interference depend on the applied technology and the separation distance. According to the studies' findings and the authors' recommendations, besides mitigating interference, using mobile phones at a reasonable distance from medical devices and developing technology standards can lead to their effective use in hospital communication systems. (authors)

  10. A clinical comparison of safety and efficacy in phacoemulsification with versus without ophthalmic viscoelastic device.

    Science.gov (United States)

    Kugu, Suleyman; Erdogan, Gurkan; Sahin Sevim, M; Ozerturk, Yusuf

    2015-03-01

    To evaluate in a comparative manner the safety and efficacy of 1.0% sodium-Hyaluronate used during capsulorhexis and intraocular lens (IOL) implantation in phacoemulsification surgery. 1.0% sodium-Hyaluronate, which is commonly used as one of the ophthalmic viscoelastic devices, was compared to intraocular irrigating solution, which can bring up these effects. In addition, the effect of both methods on occurring corneal endothelial cell (CEC) loss was investigated. Each group comprised 19 eyes. The mean preoperative CEC density was 2525.68 ± 181.85 in Group H and 2514.16 ± 174.59 in Group V; no statistically significant difference was found between the groups (p > 0.05). Preoperative and postoperative first and twelfth week CEC densities were 2438.21 ± 198.12 (p  0.05). Although it was found that there was no statistically difference in terms of preventing CEC loss between 1.0% sodium-Hyaluronate and the irrigation method during phacoemulsification, it was observed clinically that 1.0% sodium-hyaluronate can make the procedure easy, safer, very helpful, especially for understanding phacoemulsification.

  11. Modified Descemet’s Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries

    Directory of Open Access Journals (Sweden)

    Itaru Oyakawa

    2018-01-01

    Full Text Available Purpose. Descemet’s stripping automated endothelial keratoplasty (DSAEK is more difficult in hypotonic eyes with filtering bleb, due to the difficulties in elevating the intraocular pressure (IOP. We report a new method that uses ophthalmic viscoelastic devices (OVDs to achieve good graft adhesion. Case Presentation. We performed modified DSAEK surgery on 2 eyes of 2 patients, who had previously undergone a trabeculectomy. Both eyes had functioning filtering blebs; the IOP was lower than 10 mmHg without medication. After the graft was inserted into the anterior chamber, the conjunctiva was penetrated, apart from the bleb, using a 30 G needle, and Healon V® was injected into the bleb until the encapsulated space was filled completely. Air was subsequently injected into the anterior chamber to promote the graft attachment to the back surface of the cornea. The IOP was elevated above 40 mmHg in both eyes 1 h after surgery and then decreased to less than 30 mmHg over the subsequent 3 h period. The implanted graft showed good adhesion and no dislocation. Conclusions. Our novel DSAEK procedure that adds one step of OVD injection into the filtering bleb may be useful for hypotonic eyes that had undergone filtering surgeries.

  12. Ophthalmic plastic and orbital surgery in Taiwan.

    Science.gov (United States)

    Hsu, Chi-Hsin; Lin, I-Chan; Shen, Yun-Dun; Hsu, Wen-Ming

    2014-06-01

    We describe in this paper the current status of ophthalmic plastic and orbital surgery in Taiwan. Data were collected from the Bureau of National Health Insurance of Taiwan, the Bulletin of the Taiwan Ophthalmic Plastic and Reconstructive Society, and the Statistics Yearbook of Practicing Physicians and Health Care Organizations in Taiwan by the Taiwan Medical Association. We ascertained that 94 ophthalmologists were oculoplastic surgeons and accounted for 5.8% of 1621 ophthalmologists in Taiwan. They had their fellowship training abroad (most ophthalmologists trained in the United States of America) or in Taiwan. All ophthalmologists were well trained and capable of performing major oculoplastic surgeries. The payment rates by our National Health Insurance for oculoplastic and orbital surgeries are relatively low, compared to Medicare payments in the United States. Ophthalmologists should promote the concept that oculoplastic surgeons specialize in periorbital plastic and aesthetic surgeries. However, general ophthalmologists should receive more educational courses on oculoplastic and cosmetic surgery. Copyright © 2014. Published by Elsevier B.V.

  13. Medical devices and human engineering

    CERN Document Server

    Bronzino, Joseph D

    2014-01-01

    Known as the bible of biomedical engineering, The Biomedical Engineering Handbook, Fourth Edition, sets the standard against which all other references of this nature are measured. As such, it has served as a major resource for both skilled professionals and novices to biomedical engineering.Medical Devices and Human Engineering, the second volume of the handbook, presents material from respected scientists with diverse backgrounds in biomedical sensors, medical instrumentation and devices, human performance engineering, rehabilitation engineering, and clinical engineering.More than three doze

  14. Medical device reliability and associated areas

    National Research Council Canada - National Science Library

    Dhillon, Balbir S

    2000-01-01

    .... Although the history of reliability engineering can be traced back to World War II, the application of reliability engineering concepts to medical devices is a fairly recent idea that goes back to the latter part of the 1960s when many publications on medical device reliability emerged. Today, a large number of books on general reliability have been...

  15. Topical ophthalmic NSAIDs: a discussion with focus on nepafenac ophthalmic suspension

    OpenAIRE

    Gaynes, Bruce I; Onyekwuluje, Anne

    2008-01-01

    Bruce I Gaynes1,2, Anne Onyekwuluje11Departments of Ophthalmology and 2Pharmacology, Rush College of Medicine, Chicago, Illinois, USAAbstract: The removal of diclofenac sodium ophthalmic solution as a viable pharmaceutical entity in September 1999 from the US market spurred considerable interest in the general safety and effectiveness of topical ophthalmic NSAIDs for treatment of anterior segment inflammation. In late 1999 the use of topical ocular NSAIDs declined in the US as a result of inc...

  16. Model-based engineering for medical-device software.

    Science.gov (United States)

    Ray, Arnab; Jetley, Raoul; Jones, Paul L; Zhang, Yi

    2010-01-01

    This paper demonstrates the benefits of adopting model-based design techniques for engineering medical device software. By using a patient-controlled analgesic (PCA) infusion pump as a candidate medical device, the authors show how using models to capture design information allows for i) fast and efficient construction of executable device prototypes ii) creation of a standard, reusable baseline software architecture for a particular device family, iii) formal verification of the design against safety requirements, and iv) creation of a safety framework that reduces verification costs for future versions of the device software. 1.

  17. Diagnosis, treatment, and outcome of and risk factors for ophthalmic disease in leopard geckos (Eublepharis macularius) at a veterinary teaching hospital: 52 cases (1985-2013).

    Science.gov (United States)

    Wiggans, K Tomo; Sanchez-Migallon Guzman, David; Reilly, Christopher M; Vergneau-Grosset, Claire; Kass, Philip H; Hollingsworth, Steven R

    2018-02-01

    OBJECTIVE To describe diagnosis, treatment, and outcome of and risk factors for ophthalmic disease in leopard geckos (Eublepharis macularius) evaluated at a veterinary teaching hospital. DESIGN Retrospective case series. ANIMALS 112 of 144 (78%) leopard geckos that were evaluated at a veterinary teaching hospital in January 1985 through October 2013 and for which sufficient medical record information was available. PROCEDURES Information from medical records was used to identify leopard geckos with ophthalmic disease, characterize cases, and determine risk factors for the presence of ophthalmic disease. RESULTS Of the 112 leopard geckos, 52 (46%) had ophthalmic disease (mainly corneal or conjunctival disease). Female geckos were less likely to have ophthalmic disease, and there was a positive association between increasing age and ophthalmic disease. Use of a paper towel substrate, absence of any heat source, and lack of vitamin A supplementation were positively associated with a diagnosis of ophthalmic disease. Head dysecdysis was the only concurrent disorder significantly associated with ophthalmic disease. At necropsy, 5 affected leopard geckos had squamous metaplasia of the conjunctivae. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that ophthalmic disease is a common finding in leopard geckos. The cause of ocular surface disease in leopard geckos may be multifactorial, and hypovitaminosis A may be an important risk factor. Although animals receiving supplemental vitamin A were less likely to have ophthalmic disease, further understanding is required regarding the metabolism of and nutritional requirements for vitamin A in leopard geckos.

  18. [Ethic review on clinical experiments of medical devices in medical institutions].

    Science.gov (United States)

    Shuai, Wanjun; Chao, Yong; Wang, Ning; Xu, Shining

    2011-07-01

    Clinical experiments are always used to evaluate the safety and validity of medical devices. The experiments have two types of clinical trying and testing. Ethic review must be done by the ethics committee of the medical department with the qualification of clinical research, and the approval must be made before the experiments. In order to ensure the safety and validity of clinical experiments of medical devices in medical institutions, the contents, process and approval criterions of the ethic review were analyzed and discussed.

  19. The Use of Flow Diverting Stents to Treat Para-Ophthalmic Aneurysms

    Directory of Open Access Journals (Sweden)

    Pervinder Bhogal

    2017-08-01

    Full Text Available Background and purposeFew publications have dealt exclusively with the use of flow diverter stents for the treatment of para-ophthalmic aneurysms. We sought to determine the efficacy of flow diverting stents (FDSs to treat aneurysms in this specific location.MethodsWe retrospectively reviewed our database of prospectively collected information for all patients treated with flow diversion for an unruptured saccular para-ophthalmic aneurysm between September 2009 and January 2016. The aneurysm fundus size, neck size, number and type of FDS, complications, and follow-up data were recorded.ResultsWe identified 74 patients that matched our inclusion criteria. Of these patients, 18 patients were male (24.3%. The average fundus size was 4.8 mm, 11 aneurysms had previous coil occlusions and 63 were treated solely with flow diversion. At an initial angiographic follow-up (mean avg. 3.2 months, 71.8% of the aneurysms were occluded, and at the last follow-up (mean avg. 31.8 months, 88.9% of aneurysms were occluded. One patient suffered permanent morbidity (1.36% secondary to interruption of the antiplatelet medication and another died (1.36% secondary to in-stent thrombosis that was also due to an interruption in the antiplatelet medication.ConclusionTreatment of saccular para-ophthalmic aneurysms with FDS is feasible and carries a high degree of technical success with low complication rates and excellent rates of aneurysm exclusion.

  20. A concept ideation framework for medical device design.

    Science.gov (United States)

    Hagedorn, Thomas J; Grosse, Ian R; Krishnamurty, Sundar

    2015-06-01

    Medical device design is a challenging process, often requiring collaboration between medical and engineering domain experts. This collaboration can be best institutionalized through systematic knowledge transfer between the two domains coupled with effective knowledge management throughout the design innovation process. Toward this goal, we present the development of a semantic framework for medical device design that unifies a large medical ontology with detailed engineering functional models along with the repository of design innovation information contained in the US Patent Database. As part of our development, existing medical, engineering, and patent document ontologies were modified and interlinked to create a comprehensive medical device innovation and design tool with appropriate properties and semantic relations to facilitate knowledge capture, enrich existing knowledge, and enable effective knowledge reuse for different scenarios. The result is a Concept Ideation Framework for Medical Device Design (CIFMeDD). Key features of the resulting framework include function-based searching and automated inter-domain reasoning to uniquely enable identification of functionally similar procedures, tools, and inventions from multiple domains based on simple semantic searches. The significance and usefulness of the resulting framework for aiding in conceptual design and innovation in the medical realm are explored via two case studies examining medical device design problems. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Dosimetry of Sr-90 ophthalmic applicators

    International Nuclear Information System (INIS)

    Reft, C.S.; Kuchnir, F.T.; Rosenberg, I.; Myrianthopoulos, L.C.

    1990-01-01

    Sr-90 ophthalmic applicators are commonly used for the treatment of superficial eye disorders. Although a variety of dosimetric devices such as film, thermoluminescent dosimeters (TLD's), ion chambers, and radiochromic foils have been used to measure the peak dose at the applicator surface, there is no internationally agreed upon calibration procedure. Recently, large discrepancies among calibrations of the same applicator at three institutions have been reported. Here we describe a technique to obtain the peak dose rate at the applicator surface using LiF TLD's. The technique can be used for the calibration of flat as well as curved surface applicators. Results for two flat and three concave applicators are presented. Our measurement of the surface dose rate for one of the flat applicators is compared with those obtained by four other institutions, each using different dosimetric devices

  2. Power Approaches for Implantable Medical Devices

    Directory of Open Access Journals (Sweden)

    Achraf Ben Amar

    2015-11-01

    Full Text Available Implantable medical devices have been implemented to provide treatment and to assess in vivo physiological information in humans as well as animal models for medical diagnosis and prognosis, therapeutic applications and biological science studies. The advances of micro/nanotechnology dovetailed with novel biomaterials have further enhanced biocompatibility, sensitivity, longevity and reliability in newly-emerged low-cost and compact devices. Close-loop systems with both sensing and treatment functions have also been developed to provide point-of-care and personalized medicine. Nevertheless, one of the remaining challenges is whether power can be supplied sufficiently and continuously for the operation of the entire system. This issue is becoming more and more critical to the increasing need of power for wireless communication in implanted devices towards the future healthcare infrastructure, namely mobile health (m-Health. In this review paper, methodologies to transfer and harvest energy in implantable medical devices are introduced and discussed to highlight the uses and significances of various potential power sources.

  3. Ophthalmic Skills Assessment of Primary Health Care Workers at ...

    African Journals Online (AJOL)

    Proficiency in the basic ophthalmic skills is a cri cal factor in the effec ve delivery of eye care services at the primary level of care. The aim of the study was to assess the ability of ... out visual acuity test and correctly iden fy cataract and conjunc vi s using pictures of eye condi ons and ..... Medical Laboratory Technician.

  4. Does Uniformity of Topical Corticosteroid Ophthalmic Medications: Flourometholone Acetate 0.1 Suspension and Loteprednol Etabonate 0.5 gel

    Science.gov (United States)

    2017-01-03

    following ocular surgery.1 They are available in different forms including emulsions , ointments, solutions, gels, and suspensions. The choice of...study done by Stringer and Bryant compared dose uniformity of difluprednate ophthalmic emulsion (Durezol®) with prednisolone acetate (brand name...topical ophthalmic corticosteroid suspensions. Am J Ophthalmol. 1979;87(2): 210- 214. 5 Flarex® [ package insert]. Fort Worth, TX: Alcon Laboratories Inc

  5. Safety comparison of additives in antiglaucoma prostaglandin (PG analog ophthalmic formulations

    Directory of Open Access Journals (Sweden)

    Fukuda M

    2013-03-01

    Full Text Available Masamichi Fukuda, Shinsuke Shibata, Naoko Shibata, Kenta Hagihara, Hiromoto Yaguchi, Hiromi Osada, Nobuo Takahashi, Eri Kubo, Hiroshi SasakiDepartment of Ophthalmology, Kanazawa Medical University, Uchinada, JapanPurpose: To investigate the safety of five types of antiglaucoma prostaglandin analog ophthalmic formulations, and to clarify their differences in accordance with contained additives (preservatives and surface-active agents.Methods: The following five types of ophthalmic solutions and three types of additives were investigated: latanoprost (Xalatan®; latanoprost, tafluprost (Tapros®; tafluprost, bimatoprost (Lumigan®; bimatoprost, travoprost (Travatan®; travoprost, travoprost (Travatan Z®; travoprost-Z, benzalkonium chloride (BAK, polyoxyethylene hardening castor oil 40 (HCO-40, and polysorbate 80 (P-80. These experimental solutions were exposed to the cultured cells of a rabbit-derived corneal cell line for a certain time, and the exposure time causing 50% cell damage (CD50, indicated by the ratio of viable cells to total cells was calculated (in vitro. In addition, corneal resistance (CR was measured and CR ratio (post-treatment CR/pretreatment CR × 100 was calculated (in vivo.Results: CD50 of each ophthalmic solution was the longest with tafluprost, followed by travoprost-Z, bimatoprost, travoprost, and latanoprost. CD50 of 0.005%, 0.01%, and 0.02% BAK was 14.5 minutes, 8.1 minutes, and 4.0 minutes, respectively. The number of viable cells decreased to 60%, 8 minutes after exposure with HCO-40, and 30 minutes after being exposed to P-80. The CR ratio was 81.0% with travoprost and 82.0% with latanoprost, indicating a significant posttreatment reduction of CR (P < 0.05. The CR ratio did not decrease after treatment with tafluprost, travoprost-Z, or bimatoprost. The CR ratio of 0.005%, 0.01%, and 0.02% BAK was 105.0%, 90.5%, and 68.7%, respectively, and that of HCO-40 and P-80 was 108.7% and 114.2%, respectively.Conclusion: BAK

  6. Towards sustainable design for single-use medical devices.

    Science.gov (United States)

    Hanson, Jacob J; Hitchcock, Robert W

    2009-01-01

    Despite their sophistication and value, single-use medical devices have become commodity items in the developed world. Cheap raw materials along with large scale manufacturing and distribution processes have combined to make many medical devices more expensive to resterilize, package and restock than to simply discard. This practice is not sustainable or scalable on a global basis. As the petrochemicals that provide raw materials become more expensive and the global reach of these devices continues into rapidly developing economies, there is a need for device designs that take into account the total life-cycle of these products, minimize the amount of non-renewable materials consumed and consider alternative hybrid reusable / disposable approaches. In this paper, we describe a methodology to perform life cycle and functional analyses to create additional design requirements for medical devices. These types of sustainable approaches can move the medical device industry even closer to the "triple bottom line"--people, planet, profit.

  7. 78 FR 21129 - Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-04-09

    ... radiofrequency band ranging between 13 megahertz to 27.12 megahertz and is intended for the treatment of medical...] Orthopaedic and Rehabilitation Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: Orthopaedic and Rehabilitation Devices Panel of the Medical Devices...

  8. Anti-malware software and medical devices.

    Science.gov (United States)

    2010-10-01

    Just as much as healthcare information systems, medical devices need protection against cybersecurity threats. Anti-malware software can help safeguard the devices in your facility-but it has limitations and even risks. Find out what steps you can take to manage anti-malware applications in your devices.

  9. Practice of Regulatory Science (Development of Medical Devices).

    Science.gov (United States)

    Niimi, Shingo

    2017-01-01

    Prototypes of medical devices are made in accordance with the needs of clinical practice, and for systems required during the initial process of medical device development for new surgical practices. Verification of whether these prototypes produce the intended performance specifications is conducted using basic tests such as mechanical and animal tests. The prototypes are then improved and modified until satisfactory results are obtained. After a prototype passes through a clinical trial process similar to that for new drugs, application for approval is made. In the approval application process, medical devices are divided into new, improved, and generic types. Reviewers judge the validity of intended use, indications, operation procedures, and precautions, and in addition evaluate the balance between risk and benefit in terms of efficacy and safety. Other characteristics of medical devices are the need for the user to attain proficiency in usage techniques to ensure efficacy and safety, and the existence of a variety of medical devices for which assessment strategies differ, including differences in impact on the body in cases in which a physical burden to the body or failure of a medical device develops. Regulatory science of medical devices involves prediction, judgment, and evaluation of efficacy, safety, and quality, from which data result which can become indices in the development stages from design to application for approval. A reduction in the number of animals used for testing, improvement in efficiency, reduction of the necessity for clinical trials, etc. are expected through rational setting of evaluation items.

  10. Electronic compliance monitoring of topical treatment after ophthalmic surgery.

    Science.gov (United States)

    Hermann, Manuel Marcel; Ustündag, Can; Diestelhorst, Michael

    2010-08-01

    The success of many medical treatments is built on compliance. Electronic monitoring is the most accurate tool to quantify compliance by measuring adherence. In order to assess the efficiency of a recently introduced miniature monitoring device for eye drop application, we evaluated adherence in ophthalmic patients undergoing post-operative short-term topical treatment. This pilot study enrolled 30 outpatients (mean age 61.8 +/- 18.5 years) after cataract (n = 24) and glaucoma filtration surgery (n = 6) applying fixed-combination eye drops containing prednisolone and gentamicin five times daily for 2 weeks. Patients received eye drops in conventional bottles each equipped with a miniature monitoring device recording events of application. Two patients failed to bring back the monitoring device; therefore data collected from only 28 patients could be examined. Data showed highly variable results with a mean dose compliance of 50.2%. Dose compliance was below 25% in approximately one out of five patients. Four cataract patients, but no glaucoma patient, discontinued therapy prematurely. The observed mean dosage interval was calculated for each patient and ranged 4.6-19.7 h. Thirty percent of analysed dosage intervals exceeded 12.0 h. Different patterns of compliance behaviour-like early non-persistence, drug holiday and low treatment frequency could be identified and illustrated using electronic data. Age or gender did not significantly influence compliance rates. Our pilot study demonstrates successful electronic compliance monitoring using a technology capable of continuous data recording over weeks of treatment. The low compliance rate for a relevant part of the patients demonstrates the necessity to study and improve compliance in ophthalmology. In future, new application methods and electronic application devices may improve treatment response in eye care.

  11. MDR (Medical Device Reporting)

    Data.gov (United States)

    U.S. Department of Health & Human Services — This database allows you to search the CDRH's database information on medical devices which may have malfunctioned or caused a death or serious injury during the...

  12. Pulsed UV laser technologies for ophthalmic surgery

    International Nuclear Information System (INIS)

    Razhev, A M; Bagayev, S N; Churkin, D S; Kargapol’tsev, E S; Chernykh, V V; Iskakov, I A; Ermakova, O V

    2017-01-01

    The paper provides an overview of the results of multiyear joint researches of team of collaborators of Institute of Laser Physics SB RAS together with NF IRTC “Eye Microsurgery” for the period from 1988 to the present, in which were first proposed and experimentally realized laser medical technologies for correction of refractive errors of known today as LASIK, the treatment of ophthalmic herpes and open-angle glaucoma. It is proposed to carry out operations for the correction of refractive errors the use of UV excimer KrCl laser with a wavelength of 222 nm. The same laser emission is the most suitable for the treatment of ophthalmic herpes, because it has a high clinical effect, combined with many years of absence of recrudescence. A minimally invasive technique of glaucoma operations using excimer XeCl laser (λ=308 nm) is developed. Its wavelength allows perform all stages of glaucoma operations, while the laser head itself has high stability and lifetime, will significantly reduce operating costs, compared with other types of lasers. (paper)

  13. Use of mobile devices for medical imaging.

    Science.gov (United States)

    Hirschorn, David S; Choudhri, Asim F; Shih, George; Kim, Woojin

    2014-12-01

    Mobile devices have fundamentally changed personal computing, with many people forgoing the desktop and even laptop computer altogether in favor of a smaller, lighter, and cheaper device with a touch screen. Doctors and patients are beginning to expect medical images to be available on these devices for consultative viewing, if not actual diagnosis. However, this raises serious concerns with regard to the ability of existing mobile devices and networks to quickly and securely move these images. Medical images often come in large sets, which can bog down a network if not conveyed in an intelligent manner, and downloaded data on a mobile device are highly vulnerable to a breach of patient confidentiality should that device become lost or stolen. Some degree of regulation is needed to ensure that the software used to view these images allows all relevant medical information to be visible and manipulated in a clinically acceptable manner. There also needs to be a quality control mechanism to ensure that a device's display accurately conveys the image content without loss of contrast detail. Furthermore, not all mobile displays are appropriate for all types of images. The smaller displays of smart phones, for example, are not well suited for viewing entire chest radiographs, no matter how small and numerous the pixels of the display may be. All of these factors should be taken into account when deciding where, when, and how to use mobile devices for the display of medical images. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  14. 77 FR 72924 - Taxable Medical Devices

    Science.gov (United States)

    2012-12-07

    ... in hospitals, doctors offices and other medical institutions, such as x-ray machines, magnetic... the medical device context include sales to hospitals and other medical service providers. Although... of a taxable article to charity constitutes a taxable use under section 4218. However, the IRS and...

  15. Development of Implantable Medical Devices: From an Engineering Perspective

    Directory of Open Access Journals (Sweden)

    Yeun-Ho Joung

    2013-09-01

    Full Text Available From the first pacemaker implant in 1958, numerous engineering and medical activities for implantable medical device development have faced challenges in materials, battery power, functionality, electrical power consumption, size shrinkage, system delivery, and wireless communication. With explosive advances in scientific and engineering technology, many implantable medical devices such as the pacemaker, cochlear implant, and real-time blood pressure sensors have been developed and improved. This trend of progress in medical devices will continue because of the coming super-aged society, which will result in more consumers for the devices. The inner body is a special space filled with electrical, chemical, mechanical, and marine-salted reactions. Therefore, electrical connectivity and communication, corrosion, robustness, and hermeticity are key factors to be considered during the development stage. The main participants in the development stage are the user, the medical staff, and the engineer or technician. Thus, there are three different viewpoints in the development of implantable devices. In this review paper, considerations in the development of implantable medical devices will be presented from the viewpoint of an engineering mind.

  16. Preventing medical device recalls

    CERN Document Server

    Raheja, Dev

    2014-01-01

    Introduction to Medical Device RequirementsIntroductionThe ChallengesSources of ErrorsUnderstanding the Science of Safety     Overview of FDA Quality System Regulation     Overview of Risk Management Standard ISO 14971     Overview of FDA Device Approval Process     Overview of Regulatory Requirements for Clinical TrialsSummaryReferencesPreventing Recalls during Specification WritingIntroductionConduct Requirements Analysis to Identify Missing RequirementsSpecifications for Safety, Durability, and

  17. 78 FR 26786 - Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-05-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Microbiology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...

  18. 76 FR 48871 - Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-08-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Immunology Devices Panel of the Medical Devices Advisory Committee. General Function of the Committee: To...

  19. Product-based Safety Certification for Medical Devices Embedded Software.

    Science.gov (United States)

    Neto, José Augusto; Figueiredo Damásio, Jemerson; Monthaler, Paul; Morais, Misael

    2015-01-01

    Worldwide medical device embedded software certification practices are currently focused on manufacturing best practices. In Brazil, the national regulatory agency does not hold a local certification process for software-intensive medical devices and admits international certification (e.g. FDA and CE) from local and international industry to operate in the Brazilian health care market. We present here a product-based certification process as a candidate process to support the Brazilian regulatory agency ANVISA in medical device software regulation. Center of Strategic Technology for Healthcare (NUTES) medical device embedded software certification is based on a solid safety quality model and has been tested with reasonable success against the Class I risk device Generic Infusion Pump (GIP).

  20. Bromfenac ophthalmic solution for the treatment of postoperative ocular pain and inflammation: safety, efficacy, and patient adherence

    OpenAIRE

    Rajpal, Rajesh K; Ross, Bryan; Rajpal, Sachin D; Hoang, Khoa

    2014-01-01

    Rajesh K Rajpal, Bryan Ross, Sachin D Rajpal, Khoa HoangSee Clearly Vision Group, McLean, VA, USAAbstract: Ophthalmic nonsteroidal anti-inflammatory drugs (NSAIDs) are commonly used by clinicians to manage ocular inflammation and pain following cataract surgery. Over the past decade, the US Food and Drug Administration has approved multiple topical NSAIDs for these purposes, including several reformulated products. One of these medications, bromfenac ophthalmic solution, has a long and extens...

  1. On the impact of medical device regulations on software architecture

    DEFF Research Database (Denmark)

    Hansen, Klaus Marius; Manikas, Konstantinos

    2016-01-01

    Compliance to regulations and regulatory approval are requirements for many medical device software systems. In this paper, we investigate the implications of medical device software regulations to the design of software systems. We do so by focusing on the American and European regulatory author...... of the device. Moreover, we review software modularity in the implementation of software medical device and propose a set of preliminary principles for architectural design of software medical device based on a set of constrains identified from the reviewed regulations....

  2. 21 CFR 524.1982 - Proparacaine hydrochloride ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Proparacaine hydrochloride ophthalmic solution... SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1982 Proparacaine hydrochloride ophthalmic solution. (a) Specifications. The drug is...

  3. [Industry regulation and its relationship to the rapid marketing of medical devices].

    Science.gov (United States)

    Matsuoka, Atsuko

    2012-01-01

    In the market of medical devices, non-Japanese products hold a large part even in Japan. To overcome this situation, the Japanese government has been announcing policies to encourage the medical devices industry, such as the 5-year strategy for medical innovation (June 6, 2012). The Division of Medical Devices has been contributing to rapid marketing of medical devices by working out the standards for approval review and accreditation of medical devices, guidances on evaluation of medical devices with emerging technology, and test methods for biological safety evaluation of medical devices, as a part of practice in the field of regulatory science. The recent outcomes are 822 standards of accreditation for Class II medical devices, 14 guidances on safety evaluation of medical devices with emerging technology, and the revised test methods for biological safety evaluation (MHLW Notification by Director, OMDE, Yakushokuki-hatsu 0301 No. 20 "Basic Principles of Biological Safety Evaluation Required for Application for Approval to Market Medical Devices").

  4. 76 FR 7220 - Medical Device Innovation Initiative; Request for Comments

    Science.gov (United States)

    2011-02-09

    ... medical device innovation. 6. Other actions CDRH should take to facilitate the development, assessment...] Medical Device Innovation Initiative; Request for Comments AGENCY: Food and Drug Administration, HHS... availability of a document for public comment entitled ``Medical Device Innovation Initiative'' (the report...

  5. 21 CFR 524.390b - Chloramphenicol ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Chloramphenicol ophthalmic solution. 524.390b... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.390b Chloramphenicol ophthalmic solution. (a) Specifications. Each milliliter contains 5...

  6. 78 FR 68853 - International Medical Device Regulators Forum; Medical Device Single Audit Program International...

    Science.gov (United States)

    2013-11-15

    ... its inaugural meeting in Singapore in 2012, identified a Work Group (WG) to develop specific documents... Assessment Method for the Recognition and Monitoring of Medical Device Auditing Organizations;'' and IMDRF...

  7. 21 CFR 524.1044a - Gentamicin ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Gentamicin ophthalmic solution. 524.1044a Section... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1044a Gentamicin ophthalmic solution. (a) Specifications. Each milliliter of sterile aqueous...

  8. Communication: an ophthalmic practice issue.

    Science.gov (United States)

    Whitton, S J

    1995-12-01

    In the 1990's communication becomes an ophthalmic practice issue. The present ophthalmic climate of cost containment, downsizing, budget cuts, and lack of appreciation of contributions, results in a low staff morale. Recognition of the effects of job satisfaction and productivity led one group to seek solutions. A communication task force was formed to identify problems and the appropriate interventions.

  9. The current situation and development of medical device testing institutes in China.

    Science.gov (United States)

    Yang, Xiaofang; Mu, Ruihong; Fan, Yubo; Wang, Chunren; Li, Deyu

    2017-04-01

    This article analyses the current situation and development of Chinese medical device testing institutes from the perspectives of the two most important functions - testing functions and medical device standardization functions. Areas Covered: The objective of the Chinese government regulations for medical device industry is to ensure the safety and effectiveness of medical devices for Chinese patients. To support the regulation system, the Chinese government has established medical device testing institutes at different levels for example, the national, provincial, and municipal levels. These testing institutes also play an important role in technical support during medical device premarket registration and post market surveillance, they are also the vital practitioners of Chinese medical device standardization. Expert Commentary: Chinese medical device testing institutes are technical departments established by government, and serve the regulatory functions of government agency. In recent years, with the rapid development of medical device industry as well as constantly increasing international and domestic medical device market, the importance of medical device testing institute is more prominent, However, there are still some problems unsolved, such as their overall capacity remains to be improved, construction of standardization is to be strengthened, etc.

  10. Medical devices for the anesthetist: current perspectives

    Directory of Open Access Journals (Sweden)

    Ingrande J

    2014-03-01

    Full Text Available Jerry Ingrande, Hendrikus JM LemmensDepartment of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Stanford, CA, USAAbstract: Anesthesiologists are unique among most physicians in that they routinely use technology and medical devices to carry out their daily activities. Recently, there have been significant advances in medical technology. These advances have increased the number and utility of medical devices available to the anesthesiologist. There is little doubt that these new tools have improved the practice of anesthesia. Monitoring has become more comprehensive and less invasive, airway management has become easier, and placement of central venous catheters and regional nerve blockade has become faster and safer. This review focuses on key medical devices such as cardiovascular monitors, airway equipment, neuromonitoring tools, ultrasound, and target controlled drug delivery software and hardware. This review demonstrates how advances in these areas have improved the safety and efficacy of anesthesia and facilitate its administration. When applicable, indications and contraindications to the use of these novel devices will be explored as well as the controversies surrounding their use.Keywords: catheters, echocardiography, ultrasound, fiberoptic bronchoscope, laryngeal mask airway, closed-loop anesthesia

  11. 77 FR 18829 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2012-03-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory...

  12. 76 FR 71983 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-11-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory...

  13. 42 CFR 410.36 - Medical supplies, appliances, and devices: Scope.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Medical supplies, appliances, and devices: Scope... Services § 410.36 Medical supplies, appliances, and devices: Scope. (a) Medicare Part B pays for the following medical supplies, appliances and devices: (1) Surgical dressings, and splints, casts, and other...

  14. 75 FR 57968 - Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-09-23

    ...] Gastroenterology and Urology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Gastroenterology and Urology Devices Panel of the Medical Devices Advisory... committee will discuss, make recommendations, and vote on information related to the PMA for the LAP-BAND...

  15. 76 FR 55398 - Immunology Devices Panel of the Medical Devices Advisory Committee: Notice of Postponement of...

    Science.gov (United States)

    2011-09-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] Immunology Devices Panel of the Medical Devices Advisory Committee: Notice of Postponement of Meeting AGENCY... postponing the meeting of the Immunology Devices Panel of the Medical Devices Advisory Committee scheduled...

  16. Intraoperative floppy iris and prevalence of intraoperative complications: results from ophthalmic surgery outcomes database.

    Science.gov (United States)

    Vollman, David E; Gonzalez-Gonzalez, Luis A; Chomsky, Amy; Daly, Mary K; Baze, Elizabeth; Lawrence, Mary

    2014-06-01

    To estimate the prevalence of untoward events during cataract surgery with the use of pupillary expansion devices and intraoperative floppy iris (IFIS). Retrospective analysis of 4923 cataract surgery cases from the Veterans Affairs Ophthalmic Surgical Outcomes Data Project. Outcomes from 5 Veterans Affairs medical centers were analyzed, including use of alpha-blockers (both selective and nonselective), IFIS, intraoperative iris trauma, intraoperative iris prolapse, posterior capsular tear, anterior capsule tear, intraoperative vitreous prolapse, and use of pupillary expansion devices. P values were calculated using the χ(2) test. A total of 1254 patients (25.5%) took alpha-blockers preoperatively (selective, 587; nonselective, 627; both, 40). Of these 1254 patients, 428 patients (34.1%) had documented IFIS. However, 75.2% of patients with IFIS (428/569) had taken alpha-blockers preoperatively (P < .00001). A total of 430 patients (8.7%) had a pupillary expansion device used during their cataract surgery, of which 186 patients (43.4%) had IFIS (P < .0001). Eighty-six patients with IFIS had at least 1 intraoperative complication and 39 patients with IFIS had more than 1 intraoperative complication (P < .001). The use of either selective or nonselective alpha-antagonists preoperatively demonstrated a significant risk of IFIS. Nonselective alpha-antagonists caused IFIS at a higher prevalence than previously reported. This study did demonstrate statistically significant increased odds of surgical complications in patients with IFIS vs those without IFIS in all groups (those taking selective and nonselective alpha-antagonists and also those not taking medications). Published by Elsevier Inc.

  17. A Medical Delivery Device

    DEFF Research Database (Denmark)

    2010-01-01

    The present invention relates to a medical delivery device comprising at least two membrane electrode assembly units each of which comprises three layers: an upper and a lower electrode and a selective ionic conductive membrane provided there-between. At least one of the three layers are shared...

  18. Medical Device Integration Model Based on the Internet of Things

    Science.gov (United States)

    Hao, Aiyu; Wang, Ling

    2015-01-01

    At present, hospitals in our country have basically established the HIS system, which manages registration, treatment, and charge, among many others, of patients. During treatment, patients need to use medical devices repeatedly to acquire all sorts of inspection data. Currently, the output data of the medical devices are often manually input into information system, which is easy to get wrong or easy to cause mismatches between inspection reports and patients. For some small hospitals of which information construction is still relatively weak, the information generated by the devices is still presented in the form of paper reports. When doctors or patients want to have access to the data at a given time again, they can only look at the paper files. Data integration between medical devices has long been a difficult problem for the medical information system, because the data from medical devices are lack of mandatory unified global standards and have outstanding heterogeneity of devices. In order to protect their own interests, manufacturers use special protocols, etc., thus causing medical decices to still be the "lonely island" of hospital information system. Besides, unfocused application of the data will lead to failure to achieve a reasonable distribution of medical resources. With the deepening of IT construction in hospitals, medical information systems will be bound to develop towards mobile applications, intelligent analysis, and interconnection and interworking, on the premise that there is an effective medical device integration (MDI) technology. To this end, this paper presents a MDI model based on the Internet of Things (IoT). Through abstract classification, this model is able to extract the common characteristics of the devices, resolve the heterogeneous differences between them, and employ a unified protocol to integrate data between devices. And by the IoT technology, it realizes interconnection network of devices and conducts associate matching

  19. Handbook of materials for medical devices

    National Research Council Canada - National Science Library

    Davis, J. R

    2003-01-01

    ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Introduction Chapter 1 Overview of Biomaterials and Their Use in Medical Devices . . . . . . . . . . . . . . . . 1 Uses for Biomaterials...

  20. Cybersecurity and the Medical Device Product Development Lifecycle.

    Science.gov (United States)

    Jones, Richard W; Katzis, Konstantinos

    2017-01-01

    Protecting connected medical devices from evolving cyber related threats, requires a continuous lifecycle approach whereby cybersecurity is integrated within the product development lifecycle and both complements and re-enforces the safety risk management processes therein. This contribution reviews the guidance relating to medical device cybersecurity within the product development lifecycle.

  1. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    OpenAIRE

    A. Yu. Galkin; A. G. Komar; A. A. Grigorenko

    2015-01-01

    In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO...

  2. 75 FR 61507 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2010-10-05

    ...] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice... announcing an amendment to the notice of meeting of the General and Plastic Surgery Devices Panel of the..., FDA announced that a meeting of the General and Plastic Surgery Devices Panel of the Medical Devices...

  3. [Tibolone's effect on retinal and ophthalmic arteries flowmetry].

    Science.gov (United States)

    Souza, Marco Aurélio Martins de; Geber, Selmo

    2008-11-01

    to evaluate the effect of tibolone use on doppler-velocimetric parameters of ophthalmic and retinal arteries. clinical, prospective, longitudinal, randomized, placebo-controlled, triple-blind study, in which among 100 menopausal women, 50 have used 2.5 mg of the active principle tibolone (Tib Group) and 50, placebo as a means to form the control-group (Plac Group). In the Tib Group, 44 of the 50 women returned after 84 days to finish the exams, and in the Plac Group, 47. The ophthalmic and retinal arteries were studied to determine the resistance index (RI), the pulsatility index (PI) and the systole/diastole ratio (S/D). Assessments have been done before and 84 days after medication. The t-Student test has been used for the comparison of means between the groups in independent samples, as well as for within-group comparisons in dependent samples. in both groups, the women's characteristics were similar in age, menopause duration, body mass index, arterial blood pressure, deliveries and cardiac rate. The Tib Group presented the following values in the ophthalmic artery: RI(pre)=0.71+/-0.05, RI(post)0.72+/-0.08 (p=0.43); PI(pre)=1.29+/-0.22, PI(post)=1.30+/-0.25 (p=0.4) and S/D(pre)=3.49+/-0.77, SD(post)=3.65+/-0.94 (p=0.32). In the retinal artery, the following values have been found: RI(pre)=0.67+/-0.09, RI(post)=0.69+/-0.10 (p=0.7); PI(pre)=1.20+/-0.29, PI(post)=1.22+/-0.3 (p=0.2) and SD(pre)=3.29+/-0.95, SD(post)=3.30+/-1.07 (p=0.3). Also, the tibolone and control groups did not show any significant difference in regard to the above indexes in the end of the study. the 2.5 mg dose of tibolone had no effect on the Doppler velocimetry indexes of the ophthalmic and retinal arteries.

  4. Sildenafil dilates ophthalmic artery in type 2 diabetic patients

    Directory of Open Access Journals (Sweden)

    Akeel AMH Zwain

    2013-08-01

    Full Text Available Background: Conflicting reports exist on the effect of sildenafil on ophthalmic artery blood flow; many visual disturbances due to vascular insult were reported with the use of sildenafil in diabetic patients like nonarteritic ischemic optic neuropathy. Objectives: The present work aimed to investigate whether sildenafil modulates ophthalmic artery vasoreactivity in patients with type 2 diabetes mellitus. Literature reports on this aspect are lacking. Methods: A total of 35 male subjects were enrolled in this study, 18 with type 2 diabetes mellitus matched with 17 normal individuals. Ophthalmic artery was insonated through a transorbital window using colored Doppler equipment with transcranial Doppler facility. Ophthalmic artery reactivity was assessed using breath holding/hyperventilation test, before and after giving 50 mg oral sildenafil. Results: It was found that in both normal subjects and diabetic patients, sildenafil increased baseline control of mean flow velocity of ophthalmic artery significantly (p 0.05 after sildenafil, in normal and diabetic groups. There was a significant increase of resistive index of ophthalmic artery flow in diabetic patients compared with that of normal subject (p < 0.05. Sildenafil decreased resistive index of ophthalmic artery flow significantly only in diabetic patients (p < 0.05. Conclusion: Sildenafil increased MFVopa, but had no significant effect on vasoreactivity of ophthalmic artery; sildenafil decreased resistive index only in type 2 diabetic patients.

  5. Dose uniformity of loteprednol etabonate ophthalmic gel (0.5% compared with branded and generic prednisolone acetate ophthalmic suspension (1%

    Directory of Open Access Journals (Sweden)

    Marlowe ZT

    2013-12-01

    Full Text Available Zora T Marlowe, Stephen R DavioPharmaceutical Product Development, Global Pharmaceutical Research and Development, Bausch and Lomb, Inc, Rochester, NY, USAIntroduction: Loteprednol etabonate (LE ophthalmic gel 0.5% (Lotemax® is a new polycarbophil-based, nonsettling topical ophthalmic formulation. The formulation is a semisolid gel at rest and a shear thinning fluid when expressed through a dropper tip. The present study was undertaken to determine how the nonsettling character of LE ophthalmic gel affects dose uniformity. Prednisolone acetate ophthalmic suspension 1% (Pred Forte® and a generic prednisolone acetate suspension 1% were used as comparators.Methods: Drug concentrations of LE ophthalmic gel, Pred Forte, and a generic prednisolone acetate suspension were determined following simulated dosing – consisting of 2 drops, expressed four times daily for 2 weeks, with bottles that were shaken or not shaken immediately prior to expressing the drops. Drug concentrations were determined using a reverse-phase high-performance liquid chromatography (HPLC method and reported as a percentage of the declared (labeled concentration. Comparative kinetics of drug particle sedimentation were also determined for each formulation, using dispersion analysis under gravity.Results: Mean drug concentrations in drops of all three formulations were within a few percentage points of the declared concentration when the bottles were shaken for 5 seconds prior to dispensing. Only LE ophthalmic gel showed consistent and on-target concentrations when the bottles were unshaken prior to dispensing, with a mean (standard deviation [SD] percent declared concentration of 102% (1.92% over the 2-week dosing regimen. Drug concentrations for the branded and generic prednisolone acetate suspensions following expression from unshaken bottles were highly variable (overall relative SDs of 16.8% and 20.3%, respectively, with mean concentrations for both falling significantly

  6. Medical device risk management and its economic impact

    Directory of Open Access Journals (Sweden)

    Katerina Krsteva Jakimovska

    2013-10-01

    Full Text Available The importance of medical devices in everyday users/patients lives is imensse. This is the reason why emphasis must be put on safety during their use. Satisfactory safety level can be achived by implementation of quality and risk management standards. Medical device manufacturers must learn to deal with the potential risks by using theoretical and practical examples and measures in order to protect their users/patients and themselves from suffering huge losses arising from adverse events or recall of their products. The best moment for implementation of risk management methods and analysis begins from the device design and development through manufacturing, sales and distribution. These way medical device manufacturers will succseed in protecting their users/patients from serious adverse events and at the same time protect their brand and society status, while minimizing economic losses.

  7. 75 FR 47606 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-08-06

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of... General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee scheduled for August...

  8. [Design and application of implantable medical device information management system].

    Science.gov (United States)

    Cao, Shaoping; Yin, Chunguang; Zhao, Zhenying

    2013-03-01

    Through the establishment of implantable medical device information management system, with the aid of the regional joint sharing of resources, we further enhance the implantable medical device traceability management level, strengthen quality management, control of medical risk.

  9. 78 FR 16684 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-03-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  10. 77 FR 20642 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2012-04-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2012-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  11. 76 FR 14415 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-03-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  12. 76 FR 62419 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-10-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  13. 75 FR 49940 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2010-08-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  14. 78 FR 30928 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2013-05-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0001] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  15. 76 FR 39882 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-07-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0478] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting... the public. Name of Committee: General and Plastic Surgery Devices Panel of the Medical Devices...

  16. Design considerations for medical devices in the home environment.

    Science.gov (United States)

    Kaufman-Rivi, Diana; Collins-Mitchell, Janette; Jetley, Raoul

    2010-01-01

    Patient demographics, economic forces, and technological advancements contribute to the rise in home care services. Advanced medical devices and equipment originally designed for use by trained personnel in hospitals and clinics are increasingly migrating into the home. Unlike the clinical setting, the home is an uncontrolled environment with additional hazards. The compatibility of the device with the recipient's knowledge, abilities, lifestyle, and home environment plays a significant role in their therapy and rehabilitation. The advent of new device technologies such as wireless devices and interoperability of systems lends a new and complex perspective for medical device use in the home that must also be addressed. Adequately assessing and matching the patient and their caregiver with the appropriate device technology while considering the suitability of the home environment for device operation and maintenance is a challenge that relies on good human factors principles. There is a need to address these challenges in the growing home care sector In this article, the authors take a look at some important considerations and design issues for medical devices used in the home care environment.

  17. Dose uniformity of loteprednol etabonate ophthalmic gel (0.5%) compared with branded and generic prednisolone acetate ophthalmic suspension (1%).

    Science.gov (United States)

    Marlowe, Zora T; Davio, Stephen R

    2014-01-01

    Loteprednol etabonate (LE) ophthalmic gel 0.5% (Lotemax®) is a new polycarbophil-based, nonsettling topical ophthalmic formulation. The formulation is a semisolid gel at rest and a shear thinning fluid when expressed through a dropper tip. The present study was undertaken to determine how the nonsettling character of LE ophthalmic gel affects dose uniformity. Prednisolone acetate ophthalmic suspension 1% (Pred Forte®) and a generic prednisolone acetate suspension 1% were used as comparators. Drug concentrations of LE ophthalmic gel, Pred Forte, and a generic prednisolone acetate suspension were determined following simulated dosing - consisting of 2 drops, expressed four times daily for 2 weeks, with bottles that were shaken or not shaken immediately prior to expressing the drops. Drug concentrations were determined using a reverse-phase high-performance liquid chromatography (HPLC) method and reported as a percentage of the declared (labeled) concentration. Comparative kinetics of drug particle sedimentation were also determined for each formulation, using dispersion analysis under gravity. Mean drug concentrations in drops of all three formulations were within a few percentage points of the declared concentration when the bottles were shaken for 5 seconds prior to dispensing. Only LE ophthalmic gel showed consistent and on-target concentrations when the bottles were unshaken prior to dispensing, with a mean (standard deviation [SD]) percent declared concentration of 102% (1.92%) over the 2-week dosing regimen. Drug concentrations for the branded and generic prednisolone acetate suspensions following expression from unshaken bottles were highly variable (overall relative SDs of 16.8% and 20.3%, respectively), with mean concentrations for both falling significantly below the declared concentration for drops expressed at the beginning of the 2-week dosing regimen and significantly above the declared concentration for drops expressed near the end of the dosing

  18. Implantable Medical Devices; Networking Security Survey

    Directory of Open Access Journals (Sweden)

    Siamak Aram

    2016-08-01

    Full Text Available The industry of implantable medical devices (IMDs is constantly evolving, which is dictated by the pressing need to comprehensively address new challenges in the healthcare field. Accordingly, IMDs are becoming more and more sophisticated. Not long ago, the range of IMDs’ technical capacities was expanded, making it possible to establish Internet connection in case of necessity and/or emergency situation for the patient. At the same time, while the web connectivity of today’s implantable devices is rather advanced, the issue of equipping the IMDs with sufficiently strong security system remains unresolved. In fact, IMDs have relatively weak security mechanisms which render them vulnerable to cyber-attacks that compromise the quality of IMDs’ functionalities. This study revolves around the security deficiencies inherent to three types of sensor-based medical devices; biosensors, insulin pump systems and implantable cardioverter defibrillators. Manufacturers of these devices should take into consideration that security and effectiveness of the functionality of implants is highly dependent on the design. In this paper, we present a comprehensive study of IMDs’ architecture and specifically investigate their vulnerabilities at networking interface.

  19. MedMon: securing medical devices through wireless monitoring and anomaly detection.

    Science.gov (United States)

    Zhang, Meng; Raghunathan, Anand; Jha, Niraj K

    2013-12-01

    Rapid advances in personal healthcare systems based on implantable and wearable medical devices promise to greatly improve the quality of diagnosis and treatment for a range of medical conditions. However, the increasing programmability and wireless connectivity of medical devices also open up opportunities for malicious attackers. Unfortunately, implantable/wearable medical devices come with extreme size and power constraints, and unique usage models, making it infeasible to simply borrow conventional security solutions such as cryptography. We propose a general framework for securing medical devices based on wireless channel monitoring and anomaly detection. Our proposal is based on a medical security monitor (MedMon) that snoops on all the radio-frequency wireless communications to/from medical devices and uses multi-layered anomaly detection to identify potentially malicious transactions. Upon detection of a malicious transaction, MedMon takes appropriate response actions, which could range from passive (notifying the user) to active (jamming the packets so that they do not reach the medical device). A key benefit of MedMon is that it is applicable to existing medical devices that are in use by patients, with no hardware or software modifications to them. Consequently, it also leads to zero power overheads on these devices. We demonstrate the feasibility of our proposal by developing a prototype implementation for an insulin delivery system using off-the-shelf components (USRP software-defined radio). We evaluate its effectiveness under several attack scenarios. Our results show that MedMon can detect virtually all naive attacks and a large fraction of more sophisticated attacks, suggesting that it is an effective approach to enhancing the security of medical devices.

  20. Extractables characterization for five materials of construction representative of packaging systems used for parenteral and ophthalmic drug products.

    Science.gov (United States)

    Jenke, Dennis; Castner, James; Egert, Thomas; Feinberg, Tom; Hendricker, Alan; Houston, Christopher; Hunt, Desmond G; Lynch, Michael; Shaw, Arthur; Nicholas, Kumudini; Norwood, Daniel L; Paskiet, Diane; Ruberto, Michael; Smith, Edward J; Holcomb, Frank

    2013-01-01

    Polymeric and elastomeric materials are commonly encountered in medical devices and packaging systems used to manufacture, store, deliver, and/or administer drug products. Characterizing extractables from such materials is a necessary step in establishing their suitability for use in these applications. In this study, five individual materials representative of polymers and elastomers commonly used in packaging systems and devices were extracted under conditions and with solvents that are relevant to parenteral and ophthalmic drug products (PODPs). Extraction methods included elevated temperature sealed vessel extraction, sonication, refluxing, and Soxhlet extraction. Extraction solvents included a low-pH (pH = 2.5) salt mixture, a high-pH (pH = 9.5) phosphate buffer, a 1/1 isopropanol/water mixture, isopropanol, and hexane. The resulting extracts were chemically characterized via spectroscopic and chromatographic means to establish the metal/trace element and organic extractables profiles. Additionally, the test articles themselves were tested for volatile organic substances. The results of this testing established the extractables profiles of the test articles, which are reported herein. Trends in the extractables, and their estimated concentrations, as a function of the extraction and testing methodologies are considered in the context of the use of the test article in medical applications and with respect to establishing best demonstrated practices for extractables profiling of materials used in PODP-related packaging systems and devices. Plastic and rubber materials are commonly encountered in medical devices and packaging/delivery systems for drug products. Characterizing the extractables from these materials is an important part of determining that they are suitable for use. In this study, five materials representative of plastics and rubbers used in packaging and medical devices were extracted by several means, and the extracts were analytically

  1. 21 CFR 524.1200b - Kanamycin ophthalmic aqueous solution.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Kanamycin ophthalmic aqueous solution. 524.1200b... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1200b Kanamycin ophthalmic aqueous solution. (a) Specifications. The drug, which is in an aqueous...

  2. Risk evaluation of medical and industrial radiation devices

    International Nuclear Information System (INIS)

    Jones, E.D.; Cunningham, R.E.; Rathbun, P.A.

    1994-03-01

    In 1991, the NRC, Division of Industrial and Medical Nuclear Safety, began a program to evaluate the use of probabilistic risk assessment (PRA) in regulating medical devices. This program represents an initial step in an overall plant to evaluate the use of PRA in regulating the use of nuclear by-product materials. The NRC envisioned that the use of risk analysis techniques could assist staff in ensuring that the regulatory approach was standardized, understandable, and effective. Traditional methods of assessing risk in nuclear power plants may be inappropriate to use in assessing the use of by-product devices. The approaches used in assessing nuclear reactor risks are equipment-oriented. Secondary attention is paid to the human component, for the most part after critical system failure events have been identified. This paper describes the risk methodology developed by Lawrence Livermore National Laboratory (LLNL), initially intended to assess risks associated with the use of the Gamma Knife, a gamma stereotactic radiosurgical device. For relatively new medical devices such as the Gamma Knife, the challenge is to perform a risk analysis with very little quantitative data but with an important human factor component. The method described below provides a basic approach for identifying the most likely risk contributors and evaluating their relative importance. The risk analysis approach developed for the Gamma Knife and described in this paper should be applicable to a broader class of devices in which the human interaction with the device is a prominent factor. In this sense, the method could be a prototypical model of nuclear medical or industrial device risk analysis

  3. Value-based purchasing of medical devices.

    Science.gov (United States)

    Obremskey, William T; Dail, Teresa; Jahangir, A Alex

    2012-04-01

    Health care in the United States is known for its continued innovation and production of new devices and techniques. While the intention of these devices is to improve the delivery and outcome of patient care, they do not always achieve this goal. As new technologies enter the market, hospitals and physicians must determine which of these new devices to incorporate into practice, and it is important these devices bring value to patient care. We provide a model of a physician-engaged process to decrease cost and increase review of physician preference items. We describe the challenges, implementation, and outcomes of cost reduction and product stabilization of a value-based process for purchasing medical devices at a major academic medical center. We implemented a physician-driven committee that standardized and utilized evidence-based, clinically sound, and financially responsible methods for introducing or consolidating new supplies, devices, and technology for patient care. This committee worked with institutional finance and administrative leaders to accomplish its goals. Utilizing this physician-driven committee, we provided access to new products, standardized some products, decreased costs of physician preference items 11% to 26% across service lines, and achieved savings of greater than $8 million per year. The implementation of a facility-based technology assessment committee that critically evaluates new technology can decrease hospital costs on implants and standardize some product lines.

  4. Medical instruments and devices principles and practices

    CERN Document Server

    Schreiner, Steven; Peterson, Donald R

    2015-01-01

    Medical Instruments and Devices: Principles and Practices originates from the medical instruments and devices section of The Biomedical Engineering Handbook, Fourth Edition. Top experts in the field provide material that spans this wide field. The text examines how biopotential amplifiers help regulate the quality and content of measured signals. It includes instruments and devices that span a range of physiological systems and the physiological scale: molecular, cellular, organ, and system. The book chronicles the evolution of pacemakers and their system operation and discusses oscillometry, cardiac output measurement, and the direct and indirect methods of measuring cardiac output. The authors also expound on the mechanics and safety of defibrillators and cover implantable stimulators, respiration, and the structure and function of mechanical ventilators. In addition, this text covers in depth: Anesthesia Delivery Electrosurgical Units and Devices Biomedical Lasers Measuring Cellular Traction Forces Blood G...

  5. Alternative methods of ophthalmic treatment in Russia.

    Science.gov (United States)

    Vader, L

    1994-04-01

    Russian ophthalmic nurses and physicians are using alternative methods of treatment to supplement traditional eye care. As acupuncture and iridology become more popular in the United States, ophthalmic nurses need to be more knowledgeable about these treatments and the implications for patients.

  6. Instructions included? Make safety training part of medical device procurement process.

    Science.gov (United States)

    Keller, James P

    2010-04-01

    Before hospitals embrace new technologies, it's important that medical personnel agree on how best to use them. Likewise, hospitals must provide the support to operate these sophisticated devices safely. With this in mind, it's wise for hospitals to include medical device training in the procurement process. Moreover, purchasing professionals can play a key role in helping to increase the amount of user training for medical devices and systems. What steps should you take to help ensure that new medical devices are implemented safely? Here are some tips.

  7. The potential of medical device industry in technological and economical context.

    Science.gov (United States)

    Maresova, Petra; Penhaker, Marek; Selamat, Ali; Kuca, Kamil

    2015-01-01

    The high quality of public health improves not only healthy life expectancy, but also the productivity of labor. The most important part of the health care sector is the medical technology industry. The aim of this study is to analyze the current situation in the medical device industry in Europe, its potential strengths and weaknesses in the context of topical economic and demographic development. The contribution specifies an analysis of the economic state of the medical device industry in the context of demographic development of European Union's macroeconomic indicators and views of experts in the field of medical device development, concerning the opportunities for entities involved in the medical device market. There is fierce competition on the European market. The innovative activity is stable and well regulated by responsible authorities. Worldwide, the medical device market is expected to grow.

  8. 77 FR 14272 - Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological...

    Science.gov (United States)

    2012-03-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2012-N-0165] Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus... AND MICROBIOLOGY DEVICES 0 1. The authority citation for 21 CFR part 866 continues to read as follows...

  9. Regulatory affairs for biomaterials and medical devices

    CERN Document Server

    Amato, Stephen F; Amato, B

    2015-01-01

    All biomaterials and medical devices are subject to a long list of regulatory practises and policies which must be adhered to in order to receive clearance. This book provides readers with information on the systems in place in the USA and the rest of the world. Chapters focus on a series of procedures and policies including topics such as commercialization, clinical development, general good practise manufacturing and post market surveillance.Addresses global regulations and regulatory issues surrounding biomaterials and medical devicesEspecially useful for smaller co

  10. INTERFACE ELECTRONIC MEDICAL CARD ON MOBILE DEVICE

    Directory of Open Access Journals (Sweden)

    Y. L. Nechyporenko

    2013-05-01

    Full Text Available The concept designed by electronic medical card for heterogeneous environment of medical information systems at various levels. Appropriate model and technical solution. Done evaluating operating systems for mobile devices. Designed and produced by the project mobile application on Android OS as an electronic medical record on a Tablet PC Acer.

  11. Growing pains: medical device interoperability. Regulators and new standards are helping to bring about the convergence of medical devices and information management systems on IT networks.

    Science.gov (United States)

    Degaspari, John

    2011-07-01

    Both provider organizations and medical device vendors have made significant, if slow-going, progress over the last several years to network their digitally-enabled medical devices. Recent strides in both the regulatory and standards arenas have provided renewed impetus on the part of both stakeholder groups to bring more interoperability to disparate medical devices, resulting in better security and quality of patient data.

  12. 78 FR 18233 - Medical Devices; Technical Amendment

    Science.gov (United States)

    2013-03-26

    ... human environment. Therefore, neither an environmental assessment nor an environmental impact statement..., Confidential business information, Medical devices, Medical research, Reporting and recordkeeping requirements... revising the second sentence in paragraph (a) to read as follows: Sec. 870.3600 External pacemaker pulse...

  13. A new kind of monitor for ophthalmic operation

    International Nuclear Information System (INIS)

    Li, G; Wang, L L; Wang, Y; Lin, L; Jiang, W; Lu, Stephen C-Y; Besio, Walter G

    2005-01-01

    The integrity of the vision channel is often checked using VEP in order to avoiding damaging important tissue during an ophthalmic operation. But the measurement of before operations has strong side effects, it may damage the eyeball. We will introduce a new kind for monitoring ophthalmic operations in this paper. It uses visual electrical evoked potential to check the integrity of the vision access and it can monitor ophthalmic operations and avoid damaging any tissue, so it ensures the safety of the operation

  14. A new kind of monitor for ophthalmic operation

    Energy Technology Data Exchange (ETDEWEB)

    Li, G [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Wang, L L [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Wang, Y [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Lin, L [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Jiang, W [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Lu, Stephen C-Y [College of Precision Instrument and Opto-Electronics Engineering, Tianjin University, Tianjin, 300072 (China); Besio, Walter G [Biomedical Engineering Program, and Center for Biomedical Engineering and Rehabilitation Science Louisiana Tech. University, LA (United States)

    2005-01-01

    The integrity of the vision channel is often checked using VEP in order to avoiding damaging important tissue during an ophthalmic operation. But the measurement of before operations has strong side effects, it may damage the eyeball. We will introduce a new kind for monitoring ophthalmic operations in this paper. It uses visual electrical evoked potential to check the integrity of the vision access and it can monitor ophthalmic operations and avoid damaging any tissue, so it ensures the safety of the operation.

  15. 76 FR 65200 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee: Notice of...

    Science.gov (United States)

    2011-10-20

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0002] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee: Notice of... Administration (FDA) is postponing the meeting of the General and Plastic Surgery Devices Panel of the Medical...

  16. Prospects of radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Hosobuchi, Kazunari

    1992-01-01

    Since radiation sterilization was first introduced in the United States in 1956 in the field of disposable medical devices, it has become an indispensable technique for sterilization because of the following reasons: (1) introduction into dialyzers, (2) introduction in medical device makers, (3) development of disposable medical devices associated with developing both high molecular chemistry and cool sterilization, (4) rationality of sterilization process, and (5) problems of sterilization with ethylene oxide gas. To promote the further development of radiation sterilization, the following items are considered necessary: (1) an increase in the number of facilities for radiation sterilization, (2) recommendation of the international standardization of sterilization method, (3) decrease in radiation doses associated with sterilization, (4) development of electron accelerators and bremsstrahlung equipments for radiation sources, and (5) simplification of sterilization process management. Factors precluding the development of radiation sterilization are: (1) development of other methods than radiation sterilization, (2) development of technique for sterile products, (3) high facility cost, (4) high irradiation cost, (5) benefits and limits of sterilization markets, and (6) influences of materials. (N.K.)

  17. determinants of general anaesthesia for ophthalmic surgery

    African Journals Online (AJOL)

    DR. CHARLES IMARENGIAYE

    1999-08-01

    Objectives: To study the pattern of anaesthesia for ophthalmic procedures in order to improve the scheduling of cases in the ophthalmic operating room. Methods: The surgical register of the operating room from. August 01, 1999 to July 31, 2004 was examined, to document the types of procedure, timing of surgery (elective ...

  18. Assurance Cases for Medical Devices

    Science.gov (United States)

    2011-04-28

    the patient, and the hospital setting. Some pumps allow the patient to control part of the injection process (e.g. to inject more painkiller ...overdose, incorrect therapy, etc.   Design and development decisions that bear on safety and effectiveness http://www.fda.gov/MedicalDevices

  19. Electronic medical devices: a primer for pathologists.

    Science.gov (United States)

    Weitzman, James B

    2003-07-01

    Electronic medical devices (EMDs) with downloadable memories, such as implantable cardiac pacemakers, defibrillators, drug pumps, insulin pumps, and glucose monitors, are now an integral part of routine medical practice in the United States, and functional organ replacements, such as the artificial heart, pancreas, and retina, will most likely become commonplace in the near future. Often, EMDs end up in the hands of the pathologist as a surgical specimen or at autopsy. No established guidelines for systematic examination and reporting or comprehensive reviews of EMDs currently exist for the pathologist. To provide pathologists with a general overview of EMDs, including a brief history; epidemiology; essential technical aspects, indications, contraindications, and complications of selected devices; potential applications in pathology; relevant government regulations; and suggested examination and reporting guidelines. Articles indexed on PubMed of the National Library of Medicine, various medical and history of medicine textbooks, US Food and Drug Administration publications and product information, and specifications provided by device manufacturers. Studies were selected on the basis of relevance to the study objectives. Descriptive data were selected by the author. Suggested examination and reporting guidelines for EMDs received as surgical specimens and retrieved at autopsy. Electronic medical devices received as surgical specimens and retrieved at autopsy are increasing in number and level of sophistication. They should be systematically examined and reported, should have electronic memories downloaded when indicated, will help pathologists answer more questions with greater certainty, and should become an integral part of the formal knowledge base, research focus, training, and practice of pathology.

  20. Wearable Devices in Medical Internet of Things: Scientific Research and Commercially Available Devices.

    Science.gov (United States)

    Haghi, Mostafa; Thurow, Kerstin; Stoll, Regina

    2017-01-01

    Wearable devices are currently at the heart of just about every discussion related to the Internet of Things. The requirement for self-health monitoring and preventive medicine is increasing due to the projected dramatic increase in the number of elderly people until 2020. Developed technologies are truly able to reduce the overall costs for prevention and monitoring. This is possible by constantly monitoring health indicators in various areas, and in particular, wearable devices are considered to carry this task out. These wearable devices and mobile apps now have been integrated with telemedicine and telehealth efficiently, to structure the medical Internet of Things. This paper reviews wearable health care devices both in scientific papers and commercial efforts. MIoT is demonstrated through a defined architecture design, including hardware and software dealing with wearable devices, sensors, smart phones, medical application, and medical station analyzers for further diagnosis and data storage. Wearables, with the help of improved technology have been developed greatly and are considered reliable tools for long-term health monitoring systems. These are applied in the observation of a large variety of health monitoring indicators in the environment, vital signs, and fitness. Wearable devices are now used for a wide range of healthcare observation. One of the most important elements essential in data collection is the sensor. During recent years with improvement in semiconductor technology, sensors have made investigation of a full range of parameters closer to realization.

  1. The Style Evolution of Glasses: Acknowledging Well-being for Wearable Medical Device

    Directory of Open Access Journals (Sweden)

    Lydia Royeen

    2015-10-01

    Full Text Available The focus of Peta Bush’s work is to create wearable medical devices that address all qualities of the individual, including physical, mental, emotional, and psychosocial aspects. Peta is completing a practice-based research PhD titled “Therapeutic jewelry: The craft of people-centric devices for wellbeing.” Her passion for creating wearable medical devices that are multi-dimensional stems from her personal experiences, as she has Ehlers-Danlos syndrome. In addition, she uses her knowledge of well-being and the biopsychosocial model when creating her wearable medical devices. Peta currently uses technology, such as 3D printing, as one method to fabricate her collection. Her aspirations are for this concept of wearable medical devices to become mainstream, similar to glasses, and to remove the stigma associated with wearable medical devices.

  2. 78 FR 12329 - Distinguishing Medical Device Recalls From Product Enhancements; Reporting Requirements; Draft...

    Science.gov (United States)

    2013-02-22

    ... medical devices to take timely action to correct violative devices or remove them from the marketplace...] Distinguishing Medical Device Recalls From Product Enhancements; Reporting Requirements; Draft Guidance for... draft guidance entitled ``Distinguishing Medical Device Recalls From Product Enhancements; Reporting...

  3. [Thoughts on the Witnessed Audit in Medical Device Single Audit Program].

    Science.gov (United States)

    Wen, Jing; Xiao, Jiangyi; Wang, Aijun

    2018-02-08

    Medical Device Single Audit Program is one of the key projects in International Medical Device Regulators Forum, which has much experience to be used for reference. This paper briefly describes the procedures and contents of the Witnessed Audit in Medical Device Single Audit Program. Some revelations about the work of Witnessed Audit have been discussed, for reference by the Regulatory Authorities and the Auditing Organizations.

  4. 75 FR 68200 - Medical Devices; Radiology Devices; Reclassification of Full-Field Digital Mammography System

    Science.gov (United States)

    2010-11-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 892 [Docket No. FDA-2008-N-0273] Medical Devices; Radiology Devices; Reclassification of Full- Field Digital... and Drugs, 21 CFR part 892 is amended as follows: PART 892--RADIOLOGY DEVICES 0 1. The authority...

  5. Identification of Bodies by Unique Serial Numbers on Implanted Medical Devices.

    Science.gov (United States)

    Blessing, Melissa M; Lin, Peter T

    2018-05-01

    Visual identification is the most common identification method used by medical examiners but is not always possible. Alternative methods include X-ray, fingerprint, or DNA comparison, but these methods require additional resources. Comparison of serial numbers on implanted medical devices is a rapid and definitive method of identification. To assess the practicality of using this method, we reviewed 608 consecutive forensic autopsies performed at a regional medical examiner office. Of these, 56 cases required an alternative method of identification due to decomposition (n = 35), gunshot wound (n = 9), blunt trauma (n = 6), or charring (n = 6). Of these 56 cases, eight (14.3%) were known to have an implanted medical device. Of these eight cases, five (63%) could be positively identified by comparing serial numbers. If an implanted medical device is known to be present, and medical records are available, identification by medical device serial number should be a first-line method. © 2017 American Academy of Forensic Sciences.

  6. MEDIC: medical embedded device for individualized care.

    Science.gov (United States)

    Wu, Winston H; Bui, Alex A T; Batalin, Maxim A; Au, Lawrence K; Binney, Jonathan D; Kaiser, William J

    2008-02-01

    Presented work highlights the development and initial validation of a medical embedded device for individualized care (MEDIC), which is based on a novel software architecture, enabling sensor management and disease prediction capabilities, and commercially available microelectronic components, sensors and conventional personal digital assistant (PDA) (or a cell phone). In this paper, we present a general architecture for a wearable sensor system that can be customized to an individual patient's needs. This architecture is based on embedded artificial intelligence that permits autonomous operation, sensor management and inference, and may be applied to a general purpose wearable medical diagnostics. A prototype of the system has been developed based on a standard PDA and wireless sensor nodes equipped with commercially available Bluetooth radio components, permitting real-time streaming of high-bandwidth data from various physiological and contextual sensors. We also present the results of abnormal gait diagnosis using the complete system from our evaluation, and illustrate how the wearable system and its operation can be remotely configured and managed by either enterprise systems or medical personnel at centralized locations. By using commercially available hardware components and software architecture presented in this paper, the MEDIC system can be rapidly configured, providing medical researchers with broadband sensor data from remote patients and platform access to best adapt operation for diagnostic operation objectives.

  7. Medical applications for pharmacists using mobile devices.

    Science.gov (United States)

    Aungst, Timothy Dy

    2013-01-01

    Mobile devices (eg, smartphones, tablet computers) have become ubiquitous and subsequently there has been a growth in mobile applications (apps). Concurrently, mobile devices have been integrated into health care practice due to the availability and quality of medical apps. These mobile medical apps offer increased access to clinical references and point-of-care tools. However, there has been little identification of mobile medical apps suitable for the practice of pharmacy. To address the shortage of recommendations of mobile medical apps for pharmacists in daily practice. Mobile medical apps were identified via the iTunes and Google Play Stores via the "Medical" app categories and key word searches (eg, drug information, medical calculators). In addition, reviews provided by professional mobile medical app review websites were used to identify apps. Mobile medical apps were included if they had been updated in the previous 3 months, were available in the US, used evidence-based information or literature support, had dedicated app support, and demonstrated stability. Exclusion criteria included apps that were not available in English, had advertisement bias, used nonreferenced sources, were available only via an institution-only subscription, and were web-based portals. Twenty-seven mobile apps were identified and reviewed that involved general pharmacy practice, including apps that involved drug references, clinical references, medical calculators, laboratory references, news and continuing medical education, and productivity. Mobile medical apps have a variety of features that are beneficial to pharmacy practice. Individual clinicians should consider several characteristics of these apps to determine which are suitable to incorporate into their daily practice.

  8. Developing medical device software in compliance with regulations.

    Science.gov (United States)

    Zema, M; Rosati, S; Gioia, V; Knaflitz, M; Balestra, G

    2015-08-01

    In the last decade, the use of information technology (IT) in healthcare has taken a growing role. In fact, the adoption of an increasing number of computer tools has led to several benefits related to the process of patient care and allowed easier access to social and health care resources. At the same time this trend gave rise to new challenges related to the implementation of these new technologies. Software used in healthcare can be classified as medical devices depending on the way they are used and on their functional characteristics. If they are classified as medical devices they must satisfy specific regulations. The aim of this work is to present a software development framework that can allow the production of safe and high quality medical device software and to highlight the correspondence between each software development phase and the appropriate standard and/or regulation.

  9. 21 CFR 801.122 - Medical devices for processing, repacking, or manufacturing.

    Science.gov (United States)

    2010-04-01

    ....122 Medical devices for processing, repacking, or manufacturing. A device intended for processing... act if its label bears the statement “Caution: For manufacturing, processing, or repacking”. ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices for processing, repacking, or...

  10. Handheld Diagnostic Device Delivers Quick Medical Readings

    Science.gov (United States)

    2014-01-01

    To monitor astronauts' health remotely, Glenn Research Center awarded SBIR funding to Cambridge, Massachusetts-based DNA Medical Institute, which developed a device capable of analyzing blood cell counts and a variety of medical biomarkers. The technology will prove especially useful in rural areas without easy access to labs.

  11. Medical device problem reporting for the betterment of healthcare.

    Science.gov (United States)

    1998-08-01

    Given that there are nearly 5,000 individual classes of medical devices, tens of thousands of medical device suppliers, and millions of healthcare providers around the world, device-related problems are bound to happen. But effective problem reporting can help reduce or eliminate many of these problems--not only within an institution, but also potentially around the world. In this article, we trace the problem reporting process from its beginnings in the hospital to its global impact in making critical information available throughout the healthcare community.

  12. Home Healthcare Medical Devices: A Checklist

    Science.gov (United States)

    ... not using it. Contact your doctor and home healthcare team often to review your health condition. * Check ... assurance of their safety and effectiveness. A home healthcare medical device is any product or equipment used ...

  13. Radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Kaluska, I.; Stuglik, Z.

    1996-01-01

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs

  14. 77 FR 19534 - Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological...

    Science.gov (United States)

    2012-04-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2012-N-0165] Medical Devices; Immunology and Microbiology Devices; Classification of Norovirus Serological Reagents; Correction AGENCY: Food and Drug Administration, HHS. ACTION: Final rule; correction...

  15. Gasserian Ganglion and Retrobulbar Nerve Block in the Treatment of Ophthalmic Postherpetic Neuralgia: A Case Report.

    Science.gov (United States)

    Huang, Jie; Ni, Zhongge; Finch, Philip

    2017-09-01

    Varicella zoster virus reactivation can cause permanent histological changes in the central and peripheral nervous system. Neural inflammatory changes or damage to the dorsal root ganglia sensory nerve fibers during reactivation can lead to postherpetic neuralgia (PHN). For PHN of the first division of the fifth cranial nerve (ophthalmic division of the trigeminal ganglion), there is evidence of inflammatory change in the ganglion and adjacent ocular neural structures. First division trigeminal nerve PHN can prove to be difficult and sometimes even impossible to manage despite the use of a wide range of conservative measures, including anticonvulsant and antidepressant medication. Steroids have been shown to play an important role by suppressing neural inflammatory processes. We therefore chose the trigeminal ganglion as an interventional target for an 88-year-old woman with severe ophthalmic division PHN after she failed to respond to conservative treatment. Under fluoroscopic guidance, a trigeminal ganglion nerve block was performed with lidocaine combined with dexamethasone. A retrobulbar block with lidocaine and triamcinolone settled residual oculodynia. At 1-year follow-up, the patient remained pain free and did not require analgesic medication. To our knowledge, this is the first reported case of ophthalmic division PHN successfully treated with a combination of trigeminal ganglion and retrobulbar nerve block using a local anesthetic agent and steroid for central and peripheral neural inflammatory processes. © 2016 World Institute of Pain.

  16. BIOANALYTICAL STANDARDIZING FOR SEROLOGICAL DIAGNOSTIC MEDICAL DEVICES

    Directory of Open Access Journals (Sweden)

    A. Yu. Galkin

    2015-04-01

    Full Text Available In article we analyzed national and international regulations concerning the quality and safety of medical devices for in vitro diagnostics. We discussed the possibility of a partial application of the recommendations of the State Pharmacopoeia of Ukraine to this type of product. The main guiding regulatory documents establishing requirements for quality and safety tools for the serological diagnosis products are The technical regulation on medical devices for the diagnosis in vitro, DSTU ISO 13485 “Medical devices. Quality management system. Regulatory requirements”, and DSTU ISO/IEC 17025 “General requirements for the competence of testing and calibration laboratories”. Similar requirements of the State Pharmacopoeia of Ukraine which are used for drug standardization can not be directly applied to the medical devises for in vitro diagnostics due to a number of features, namely, the serological diagnosis products pre-designed to determine the unknown concentration of a particular analyte in a biological material, the diagnostic kits has to include the control samples (internal standard systems that need to be calibrated. It was determined following parameters of bioanalytical standardization and validation characterization for of qualitative (semi quantitative test-kits for serological diagnosis: precision (convergence, intralaboratory precision and reproducibility, diagnostic and analytical specificity, diagnostic sensitivity. It’s necessary to inspect additional parameters for quantitative test-kits such as accuracy (precision, linearity, analytical sensitivity and range.

  17. Ophthalmic masquerades of the atherosclerotic carotids

    Directory of Open Access Journals (Sweden)

    Anupriya Arthur

    2014-01-01

    Full Text Available Patients with carotid atherosclerosis can present with ophthalmic symptoms. These symptoms and signs can be due to retinal emboli, hypoperfusion of the retina and choroid, opening up of collateral channels, or chronic hypoperfusion of the globe (ocular ischemic syndrome. These pathological mechanisms can produce many interesting signs and a careful history can bring out important past symptoms pointing toward the carotid as the source of the patient′s presenting symptom. Such patients are at high risk for an ischemic stroke, especially in the subsequent few days following their first acute symptom. It is important for clinicians to be familiar with these ophthalmic symptoms and signs caused by carotid atherosclerosis for making an early diagnosis and to take appropriate measures to prevent a stroke. This review elaborates the clinical features, importance, and implications of various ophthalmic symptoms and signs resulting from atherosclerotic carotid artery disease.

  18. 21 CFR 886.4350 - Manual ophthalmic surgical instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual ophthalmic surgical instrument. 886.4350 Section 886.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... suturing needle, lachrymal probe, trabeculotomy probe, cornea-sclera punch, ophthalmic retractor...

  19. Liability for damage caused by shortage and failure to use necessary medical devices

    Directory of Open Access Journals (Sweden)

    Cvetković Mihajlo

    2014-01-01

    Full Text Available In order to provide for successful, safe and high quality medical services, health care institutions need to be equipped with adequate medical devices. For this reason, every medical institution is legally obliged to have relevant medical devices. In case a patient has been deprived of some medical service for the lack of necessary medical devices (which the institution has been obliged to provide, the medical institution is responsible for the damage and harm sustained by the patient. The responsibility implies non-contractual liability (in tort law or pre-contractual liability (in contract law. In both cases, the liability is based on the presumed culpability. In order to be excluded from liability, the medical institution has to prove that the patient has been deprived of medical service (or that the institution has refused to enter into a medical service provider agreement on justifiable grounds, i.e. due to the lack of necessary medical devices. On the other hand, in case the medial institutions fail to provide needed care or violate their obligation to use medical devices when necessary, it is regarded as medical negligence (professional error. In most cases, it implies the liability of medical institutions for damage, injury or harm caused to the patient by medical services provided without applying a relevant medical device, whose use has been medically indicated. The liability is even more substantial in cases where the medical device has been available but the medical institutions has not applied it in medial treatment (even though its use has been medically indicated; such conduct is qualified as gross negligence.

  20. Medical Device Plug-and-Play Interoperability Standards and Technology Leadership

    Science.gov (United States)

    2017-10-01

    Award Number: W81XWH-09-1-0705 TITLE: “Medical Device Plug-and-Play Interoperability Standards and Technology Leadership” PRINCIPAL INVESTIGATOR...Sept 2016 – 20 Sept 2017 4. TITLE AND SUBTITLE “Medical Device Plug-and-Play Interoperability 5a. CONTRACT NUMBER Standards and Technology ...efficiency through interoperable medical technologies . We played a leadership role on interoperability safety standards (AAMI, AAMI/UL Joint

  1. Transmitting patient and device data via GSM--central management for decentral mobile medical devices.

    Science.gov (United States)

    Bachmor, T; Schöchlin, J; Bolz, A

    2002-01-01

    Equipping medical devices with long range telemetry opens completely new possibilities for emergency response, home care and remote diagnosis. Mobile communications nowadays seem to be a generally accepted part of our modern world, but bridging the gap between new (consumer-) technologies and medical devices still is a challenge today. Providing a telemetry link (GSM) is just the trivial part--ensuring security, reliability and service management are the more critical tasks that need to be addressed. Therefore, a complete system concept consists of an automatic fleet management (e.g. periodic device-initiated service calls) as well as customer relationship management (CRM), including technical service and a trouble-ticket system.

  2. Medical device integration: CIOs must bridge the digital divide between devices and electronic medical records.

    Science.gov (United States)

    Raths, David

    2009-02-01

    To get funding approved for medical device integration, ClOs suggest focusing on specific patient safety or staff efficiency pain points. Organizations that make clinical engineering part of their IT team report fewer chain-of-command issues. It also helps IT people understand the clinical goals because the engineering people have been working closely with clinicians for years. A new organization has formed to work on collaboration between clinical engineers and IT professionals. For more information, go to www.ceitcollaboration.org. ECRI Institute has written a guide to handling the convergence of medical technology and hospital networks. Its "Medical Technology for the IT Professional: An Essential Guide for Working in Today's Healthcare Setting" also details how IT professionals can assist hospital technology planning and acquisition, and provide ongoing support for IT-based medical technologies. For more information, visit www.ecri.org/ITresource.

  3. Cybersecurity and medical devices: A practical guide for cardiac electrophysiologists

    Science.gov (United States)

    Kramer, Daniel B.; Foo Kune, Denis; Auto de Medeiros, Julio; Yan, Chen; Xu, Wenyuan; Crawford, Thomas; Fu, Kevin

    2017-01-01

    Abstract Medical devices increasingly depend on software. While this expands the ability of devices to perform key therapeutic and diagnostic functions, reliance on software inevitably causes exposure to hazards of security vulnerabilities. This article uses a recent high‐profile case example to outline a proactive approach to security awareness that incorporates a scientific, risk‐based analysis of security concerns that supports ongoing discussions with patients about their medical devices. PMID:28512774

  4. Medical device registration, agreements on mutual recognition - a step forward to global harmonization?

    International Nuclear Information System (INIS)

    Eidenberger, R.Reiner

    2000-01-01

    The purpose of this article is to give a short overview of some different regulations in Europe and the United States with regard to the clearance of medical devices and to give an outlook of what the Agreements on Mutual Recognition will bring in terms of Global Harmonization. Recent European legislation, the Council Directive 93/42/EEC of 14 June 1993 concerning medical devices (Medical Device Directive, MDD), requires that all medical devices placed on the European market bear the CE marking. From 14 June 1998, medical devices fall under the scope of this European Medical Device Directive and there is a harmonization within the European market. Similar to this, but for another market, are the USA FDA requirements, Premarket Approval (PMA) and Premarket notification (510(k)). The same medical device, the same goal - a safe product - but different legislation and thus duplication of registration procedures. The European Commission is presently discussing a series of agreements with third countries, Australia, New Zealand, USA, Canada, Japan and Eastern European countries wishing to join the EU, concerning the mutual acceptance of inspection bodies and, ultimately, proof of conformity (for example reports on examination, certificates, licenses and marks of conformity) in connection with medical devices. Meanwhile agreements with Australia, New Zealand, USA and Canada came into force. (author)

  5. The potential of medical device industry in technological and economical context

    Directory of Open Access Journals (Sweden)

    Maresova P

    2015-10-01

    Full Text Available Petra Maresova,1 Marek Penhaker,1,2 Ali Selamat,1,3 Kamil Kuca1,41Faculty of Informatics and Management, University of Hradec Králové, Hradec Králové, Czech Republic; 2Department of Cybernetics and Biomedical Engineering, Faculty of Electrical Engineering and Computer Science, Technical University of Ostrava, Poruba, Czech Republic; 3Faculty of Computing, Universiti Teknologi Malaysia, Johor Bahru, Johor, Malaysia; 4Center for Biomedical Research, University Hospital Hradec Králové, Hradec Králové, Czech RepublicAbstract: The high quality of public health improves not only healthy life expectancy, but also the productivity of labor. The most important part of the health care sector is the medical technology industry. The aim of this study is to analyze the current situation in the medical device industry in Europe, its potential strengths and weaknesses in the context of topical economic and demographic development. The contribution specifies an analysis of the economic state of the medical device industry in the context of demographic development of European Union’s macroeconomic indicators and views of experts in the field of medical device development, concerning the opportunities for entities involved in the medical device market. There is fierce competition on the European market. The innovative activity is stable and well regulated by responsible authorities. Worldwide, the medical device market is expected to grow.Keywords: technology context, medical device, Europe, expenditure, review

  6. To study the existing system of surgical safety for cataract surgery at tertiary care ophthalmic centre to implement WHO surgical safety checklist

    OpenAIRE

    Ruchi Garg; Neeraj Garg; Shakti Kumar Gupta; J. S. Titiyal; R. Mahesh

    2016-01-01

    Background: Dr. Rajendra Prasad Centre for Ophthalmic Sciences, named after the first President of India, was established on the 10th of March, 1967 as a National centre for ophthalmic science, to provide state of the art patient care, expand human resources for medical education and undertake research to find solutions to eye health problems of national importance. Average numbers of cataract surgeries performed per month are 700 to 1000. Methods: Anticipating implementation in 50% cases...

  7. 77 FR 4252 - Additional Spectrum for the Medical Device Radiocommunication Service

    Science.gov (United States)

    2012-01-27

    ... licensed users in these frequency bands to continue providing service. Medical Micro-Power Networks (MMNs...). Under this approach, medical devices would operate in the band on a shared, non-exclusive basis with...Radio Service rules for devices operating in the 413-457 MHz band. These definitions were for a Medical...

  8. Optical tests for using smartphones inside medical devices

    Science.gov (United States)

    Bernat, Amir S.; Acobas, Jennifer K.; Phang, Ye Shang; Hassan, David; Bolton, Frank J.; Levitz, David

    2018-02-01

    Smartphones are currently used in many medical applications and are more frequently being integrated into medical imaging devices. The regulatory requirements in existence today however, particularly the standardization of smartphone imaging through validation and verification testing, only partially cover imaging characteristics with a smartphone. Specifically, it has been shown that smartphone camera specifications are of sufficient quality for medical imaging, and there are devices which comply with the FDA's regulatory requirements for a medical device such as a device's field of view, direction of viewing and optical resolution and optical distortion. However, these regulatory requirements do not call specifically for color testing. Images of the same object using automatic settings or different light sources can show different color composition. Experimental results showing such differences are presented. Under some circumstances, such differences in color composition could potentially lead to incorrect diagnoses. It is therefore critical to control the smartphone camera and illumination parameters properly. This paper examines different smartphone camera settings that affect image quality and color composition. To test and select the correct settings, a test methodology is proposed. It aims at evaluating and testing image color correctness and white balance settings for mobile phones and LED light sources. Emphasis is placed on color consistency and deviation from gray values, specifically by evaluating the ΔC values based on the CIEL*a*b* color space. Results show that such standardization minimizes differences in color composition and thus could reduce the risk of a wrong diagnosis.

  9. Laser direct writing of micro- and nano-scale medical devices

    Science.gov (United States)

    Gittard, Shaun D; Narayan, Roger J

    2010-01-01

    Laser-based direct writing of materials has undergone significant development in recent years. The ability to modify a variety of materials at small length scales and using short production times provides laser direct writing with unique capabilities for fabrication of medical devices. In many laser-based rapid prototyping methods, microscale and submicroscale structuring of materials is controlled by computer-generated models. Various laser-based direct write methods, including selective laser sintering/melting, laser machining, matrix-assisted pulsed-laser evaporation direct write, stereolithography and two-photon polymerization, are described. Their use in fabrication of microstructured and nanostructured medical devices is discussed. Laser direct writing may be used for processing a wide variety of advanced medical devices, including patient-specific prostheses, drug delivery devices, biosensors, stents and tissue-engineering scaffolds. PMID:20420557

  10. Open-source hardware for medical devices.

    Science.gov (United States)

    Niezen, Gerrit; Eslambolchilar, Parisa; Thimbleby, Harold

    2016-04-01

    Open-source hardware is hardware whose design is made publicly available so anyone can study, modify, distribute, make and sell the design or the hardware based on that design. Some open-source hardware projects can potentially be used as active medical devices. The open-source approach offers a unique combination of advantages, including reducing costs and faster innovation. This article compares 10 of open-source healthcare projects in terms of how easy it is to obtain the required components and build the device.

  11. Evaluating and Predicting Patient Safety for Medical Devices With Integral Information Technology

    Science.gov (United States)

    2005-01-01

    323 Evaluating and Predicting Patient Safety for Medical Devices with Integral Information Technology Jiajie Zhang, Vimla L. Patel, Todd R...errors are due to inappropriate designs for user interactions, rather than mechanical failures. Evaluating and predicting patient safety in medical ...the users on the identified trouble spots in the devices. We developed two methods for evaluating and predicting patient safety in medical devices

  12. Modelling degradation of bioresorbable polymeric medical devices

    CERN Document Server

    Pan, J

    2015-01-01

    The use of bioresorbable polymers in stents, fixation devices and tissue engineering is revolutionising medicine. Both industry and academic researchers are interested in using computer modelling to replace some experiments which are costly and time consuming. This book provides readers with a comprehensive review of modelling polymers and polymeric medical devices as an alternative to practical experiments. Chapters in part one provide readers with an overview of the fundamentals of biodegradation. Part two looks at a wide range of degradation theories for bioresorbable polymers and devices.

  13. 77 FR 8260 - Agency Information Collection Activities; Proposed Collection; Comment Request; Medical Device...

    Science.gov (United States)

    2012-02-14

    ... will be used to evaluate risks associated with medical devices which will enable FDA to take...] Agency Information Collection Activities; Proposed Collection; Comment Request; Medical Device Reporting... comment in response to the notice. This notice solicits comments on medical device reporting (MDR...

  14. Audit of Referrals to an Ophthalmic Outpatient Clinic of a Tertiary ...

    African Journals Online (AJOL)

    Objectives: To determine the referral pattern and assess the quality and accuracy of referral letters to the ophthalmic outpatient clinic of University of Nigeria Teaching Hospital, Enugu. Methods: This study is a prospective cross-sectional survey of all new ophthalmic referrals to the ophthalmic outpatient clinic at University of ...

  15. Degree and duration of corneal anesthesia after topical application of 0.4% oxybuprocaine hydrochloride ophthalmic solution in ophthalmically normal dogs.

    Science.gov (United States)

    Douet, Jean-Yves; Michel, Julien; Regnier, Alain

    2013-10-01

    To assess the anesthetic efficacy and local tolerance of topically applied 0.4% oxybuprocaine ophthalmic solution to in dogs and compare its effects with those of 1% tetracaine solution. 34 ophthalmically normal Beagles. Dogs were assigned to 2 groups, and baseline corneal touch threshold (CTT) was measured bilaterally with a Cochet-Bonnet aesthesiometer. Dogs of group 1 (n = 22) received a single drop of 0.4% oxybuprocaine ophthalmic solution in one eye and saline (0.9% NaCl) solution (control treatment) in the contralateral eye. Dogs of group 2 (n = 12) received a single drop of 0.4% oxybuprocaine ophthalmic solution in one eye and 1% tetracaine ophthalmic solution in the contralateral eye. The CTT of each eye was measured 1 and 5 minutes after topical application and then at 5-minute intervals until 75 minutes after topical application. CTT changes over time differed significantly between oxybuprocaine-treated and control eyes. After instillation of oxybuprocaine, maximal corneal anesthesia (CTT = 0) was achieved within 1 minute, and CTT was significantly decreased from 1 to 45 minutes, compared with the baseline value. No significant difference in onset, depth, and duration of corneal anesthesia was found between oxybuprocaine-treated and tetracaine-treated eyes. Conjunctival hyperemia and chemosis were detected more frequently in tetracaine-treated eyes than in oxybuprocaine-treated eyes. Topical application of oxybuprocaine and tetracaine similarly reduced corneal sensitivity in dogs, but oxybuprocaine was less irritating to the conjunctiva than was tetracaine.

  16. Use-related risk analysis for medical devices based on improved FMEA.

    Science.gov (United States)

    Liu, Long; Shuai, Ma; Wang, Zhu; Li, Ping

    2012-01-01

    In order to effectively analyze and control use-related risk of medical devices, quantitative methodologies must be applied. Failure Mode and Effects Analysis (FMEA) is a proactive technique for error detection and risk reduction. In this article, an improved FMEA based on Fuzzy Mathematics and Grey Relational Theory is developed to better carry out user-related risk analysis for medical devices. As an example, the analysis process using this improved FMEA method for a certain medical device (C-arm X-ray machine) is described.

  17. Home Use Devices: How to Prepare for and Handle Power Outages for Medical Devices That Require Electricity

    Science.gov (United States)

    ... to Create a Personal Emergency File My personal emergency file contains: □ Instructions for using the medical device and all device manuals. □ First aid kit □ Medical records □ Insurance cards □ Current home care doctor’s orders □ Plan of treatment □ What a family ...

  18. Diquafosol ophthalmic solution 3 %: a review of its use in dry eye.

    Science.gov (United States)

    Keating, Gillian M

    2015-05-01

    Diquafosol ophthalmic solution 3 % (Diquas(®)) is a P2Y2 receptor agonist that promotes tear fluid and mucin secretion and is currently approved in Japan and South Korea for the treatment of dry eye. In randomized, double-blind, multicentre trials in patients with dry eye, significantly greater improvements in fluorescein and rose bengal staining scores were seen with diquafosol ophthalmic solution 3 % than with placebo, and diquafosol ophthalmic solution 3 % was noninferior to sodium hyaluronate ophthalmic solution 0.1 % in terms of the improvement in the fluorescein staining score and more effective than sodium hyaluronate ophthalmic solution 0.1 % in terms of the improvement in the rose bengal staining score. The efficacy of diquafosol ophthalmic solution 3 % in the treatment of dry eye was maintained in the longer term, with improvements also seen in subjective dry eye symptoms, and was also shown in a real-world setting. Diquafosol ophthalmic solution 3 % also demonstrated efficacy in various specific dry eye disorders, including aqueous-deficient dry eye, short tear film break-up time dry eye, obstructive meibomian gland dysfunction, dry eye following laser in situ keratomileusis surgery and dry eye following cataract surgery, as well as in contact lens wearers and visual display terminal users. Diquafosol ophthalmic solution 3 % was generally well tolerated in patients with dry eye, with eye irritation the most commonly reported adverse event. In conclusion, diquafosol ophthalmic solution 3 % is a useful option for the treatment of dry eye.

  19. Extended device profiles and testing procedures for the approval process of integrated medical devices using the IEEE 11073 communication standard.

    Science.gov (United States)

    Janß, Armin; Thorn, Johannes; Schmitz, Malte; Mildner, Alexander; Dell'Anna-Pudlik, Jasmin; Leucker, Martin; Radermacher, Klaus

    2018-02-23

    Nowadays, only closed and proprietary integrated operating room systems (IORS) from big manufacturers are available on the market. Hence, the interconnection of components from third-party vendors is only possible with increased time and costs. In the context of the German Federal Ministry of Education and Research (BMBF)-funded project OR.NET (2012-2016), the open integration of medical devices from different manufacturers was addressed. An integrated operating theater based on the open communication standard IEEE 11073 shall give clinical operators the opportunity to choose medical devices independently of the manufacturer. This approach would be advantageous especially for hospital operators and small- and medium-sized enterprises (SME) of medical devices. Actual standards and concepts regarding technical feasibility and the approval process do not cope with the requirements for a modular integration of medical devices in the operating room (OR), based on an open communication standard. Therefore, innovative approval strategies and corresponding certification and test procedures, which cover actual legal and normative standards, have to be developed in order to support the future risk management and the usability engineering process of open integrated medical devices in the OR. The use of standardized device and service profiles and a three-step testing procedure, including conformity, interoperability and integration tests are described in this paper and shall support the manufacturers to integrate their medical devices without disclosing the medical devices' risk analysis and related confidential expertise or proprietary information.

  20. A European perspective on costs and cost effectiveness of ophthalmic combinations in the treatment of open-angle glaucoma

    DEFF Research Database (Denmark)

    Hommer, A.; Thygesen, J.; Ferreras, A.

    2008-01-01

    PURPOSE: Efficacy, safety, and cost implications are important considerations when choosing an ophthalmic treatment. Fixed-combination glaucoma medications containing brimonidine 0.2% and timolol 0.5%, or dorzolamide 2% and timolol 0.5%, were compared with brimonidine 0.2% and dorzolamide 2...

  1. Rate of bacterial eradication by ophthalmic solutions of fourth-generation fluoroquinolones.

    Science.gov (United States)

    Callegan, Michelle C; Novosad, Billy D; Ramadan, Raniyah T; Wiskur, Brandt; Moyer, Andrea L

    2009-04-01

    Antibacterial activity of ophthalmic fourth-generation fluoroquinolones has traditionally been evaluated by comparing only their active ingredients, gatifloxacin and moxifloxacin. However, ophthalmic formulations of fourth-generation fluoroquinolones differ in terms of the inclusion of preservatives. While gatifloxacin ophthalmic solution 0.3% (Zymar; Allergan, Inc., Irvine, CA, USA) contains 0.005% benzalkonium chloride (BAK), moxifloxacin ophthalmic solution 0.5% (Vigamox; Alcon Laboratories, Inc., Fort Worth, TX, USA) is preservative-free. Recent studies have demonstrated that the presence of BAK dramatically affects the antibacterial activity of the ophthalmic formulation of gatifloxacin. This study was designed to compare the kill rates of ophthalmic solutions of fourth-generation fluoroquinolones against isolates of common ocular bacterial pathogens. Approximately 5.6 log(10) colony-forming units (CFU)/mL of Haemophilus influenzae (n=1), Streptococcus pneumoniae (n=1), Staphylococcus aureus (n=2), methicillin-resistant Staphylococcus aureus (MRSA) (n=4), methicillinresistant Staphylococcus epidermidis (MRSE) (n=4), and fluoroquinolone-resistant S. epidermidis (n=1) were incubated with ophthalmic solutions of either gatifloxacin or moxifloxacin. Viable bacteria were quantified at specific time points up to 60 minutes. Gatifloxacin 0.3% completely eradicated H. influenzae and Strep. pneumoniae in 5 minutes, one of two S. aureus isolates in 15 minutes, and the other S. aureus isolate in 60 minutes. Gatifloxacin 0.3% completely killed all MRSA, MRSE, and fluoroquinolone-resistant S. epidermidis isolates in 15 minutes. Moxifloxacin 0.5% completely eradicated Strep. pneumoniae and one of four MRSA isolates in 60 minutes. All other isolates incubated with moxifloxacin 0.5% retained viable bacteria ranging from 1.8 to 4.4 log(10) CFU/mL. The ophthalmic solution of gatifloxacin 0.3% eradicated bacteria that frequently cause postoperative ocular infections

  2. 76 FR 22322 - Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian Adnexal Mass...

    Science.gov (United States)

    2011-04-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2010-N-0026] Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian Adnexal Mass Assessment Score Test System; Correction AGENCY: Food and Drug Administration, HHS. ACTION...

  3. Just a piece of equipment? The importance of medical device education.

    Science.gov (United States)

    Brand, Darren

    2012-12-01

    The use of medical devices is an increasingly important element of a healthcare professional's role. It is crucial that users receive regular teaching and education to ensure that they are competent in the use of devices. This is particularly relevant in the increasingly litigious society in which we live. This article focuses upon the importance of a medical device education.

  4. 76 FR 30176 - Dermatologic and Ophthalmic Drugs Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-05-24

    ... committee will discuss biologics license application (BLA) 125387, aflibercept ophthalmic solution, proposed...] Dermatologic and Ophthalmic Drugs Advisory Committee; Notice of Meeting AGENCY: Food and Drug Administration...: Dermatologic and Ophthalmic Drugs Advisory Committee. General Function of the Committee: To provide advice and...

  5. New IEEE 11073 Standards for interoperable, networked Point-of-Care Medical Devices.

    Science.gov (United States)

    Kasparick, Martin; Schlichting, Stefan; Golatowski, Frank; Timmermann, Dirk

    2015-08-01

    Surgical procedures become more and more complex and the number of medical devices in an operating room (OR) increases continuously. Today's vendor-dependent solutions for integrated ORs are not able to handle this complexity. They can only form isolated solutions. Furthermore, high costs are a result of vendor-dependent approaches. Thus we present a service-oriented device communication for distributed medical systems that enables the integration and interconnection between medical devices among each other and to (medical) information systems, including plug-and-play functionality. This system will improve patient's safety by making technical complexity of a comprehensive integration manageable. It will be available as open standards that are part of the IEEE 11073 family of standards. The solution consists of a service-oriented communication technology, the so called Medical Devices Profile for Web Services (MDPWS), a Domain Information & Service Model, and a binding between the first two mechanisms. A proof of this concept has been done with demonstrators of real world OR devices.

  6. Protecting computer-based medical devices: defending against viruses and other threats.

    Science.gov (United States)

    2005-07-01

    The increasing integration of computer hardware has exposed medical devices to greater risks than ever before. More and more devices rely on commercial off-the-shelf software and operating systems, which are vulnerable to the increasing proliferation of viruses and other malicious programs that target computers. Therefore, it is necessary for hospitals to take steps such as those outlined in this article to ensure that their computer-based devices are made safe and continue to remain safe in the future. Maintaining the security of medical devices requires planning, careful execution, and a commitment of resources. A team should be created to develop a process for surveying the security status of all computerized devices in the hospital and making sure that patches and other updates are applied as needed. These patches and updates should be approved by the medical system supplier before being implemented. The team should consider using virtual local area networks to isolate susceptible devices on the hospital's network. All security measures should be carefully documented, and the documentation should be kept up-to-date. Above all, care must be taken to ensure that medical device security involves a collaborative, supportive partnership between the hospital's information technology staff and biomedical engineering personnel.

  7. An historical ophthalmic study of Jane Austen.

    Science.gov (United States)

    Wilson, Graham A

    2012-11-01

    Today, no other classic novelist has the popularity or power of Jane Austen, and in 2013 the world will celebrate 200 years of her comic masterpiece Pride and Prejudice. Her millions of fans have an abiding fascination with all aspects of her life, including her health and the cause of her death. This historical ophthalmic study of Jane Austen, based on very incomplete medical bibliographic data, finds that she had a mild ocular surface disorder from age 23. This disorder did not significantly impact on her visual performance for writing. There are many references to eyes in her novels, but Jane's eyes and those of her characters cannot contribute further to the debate around the cause of her death at age 41.

  8. 21 CFR 892.2010 - Medical image storage device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical image storage device. 892.2010 Section 892.2010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED..., and digital memory. (b) Classification. Class I (general controls). The device is exempt from the...

  9. [Impact of an automated dispensing system for medical devices in cardiac surgery department].

    Science.gov (United States)

    Clou, E; Dompnier, M; Kably, B; Leplay, C; Poupon, E; Archer, V; Paul, M

    2018-01-01

    To secure medical devices' management, the implementation of automated dispensing system in surgical service has been realized. The objective of this study was to evaluate security, organizational and economic impact of installing automated dispensing system for medical devices (ASDM). The implementation took place in a cardiac surgery department. Security impact was assessed by comparing traceability rate of implantable medical devices one year before and one year after installation. Questionnaire on nurses' perception and satisfaction completed this survey. Resupplying costs, stocks' evolution and investments for the implementation of ASDM were the subject of cost-benefit study. After one year, traceability rate is excellent (100%). Nursing staffs were satisfied with 87.5% by this new system. The introduction of ASDM allowed a qualitative and quantitative decrease in stocks, with a reduction of 30% for purchased medical devices and 15% for implantable medical devices in deposit-consignment. Cost-benefit analysis shows a rapid return on investment. Real stock decrease (purchased medical devices) is equivalent to 46.6% of investment. Implementation of ASDM allows to secure storage and dispensing of medical devices. This system has also an important economic impact and appreciated by users. Copyright © 2017 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  10. Development and Effects of FTY720 Ophthalmic Solution on Corneal Allograft Survival.

    Science.gov (United States)

    Liu, Zhaochuan; Lin, Haotian; Huang, Chulong; Chen, Wan; Xiang, Wu; Geng, Yu; Chen, Weirong

    2015-11-12

    Fingolimod (FTY720), a novel class of sphingosine 1-phosphate receptor modulators, has received special interest among ophthalmologists, particularly given that oral administration of FTY720 has proven to effectively treat corneal graft rejection in animal models. However, no studies have examined the performance of FTY720 as an ophthalmic solution in reducing corneal rejection in high-risk corneal rejection models, and the stability and ocular irritation profile of FTY720 ophthalmic solution are also unknown. Thus, we developed 0.1%, 0.2% and 0.5% FTY720 ophthalmic solutions and evaluated their chemical stabilities under various storage conditions with high- performance liquid chromatography. To investigate the ocular irritancy of the FTY720 ophthalmic solution, New Zealand albino rabbits were subjected to the Draize test. Furthermore, classic, well-established rat allogenic penetrating keratoplasty models were used to investigate the anti-rejection efficacy of the tested FTY720 ophthalmic solutions. We found that the non-irritating 0.5% FTY720 ophthalmic solution could prolong corneal allograft survival in rats with significant efficacy for about one month. Furthermore, no significant concentration changes occurred in any of the types of FTY720 ophthalmic solutions within three months. These results revealed crucial profiles of FTY720 ophthalmic solutions and warrant further investigation and optimization of FTY720 in the anti-rejection therapy after keratoplasty.

  11. [Regulatory Program for Medical Devices in Cuba: experiences and current challenges].

    Science.gov (United States)

    Pereira, Dulce María Martínez; Rodríguez, Yadira Álvarez; Valdés, Yamila Cedeño; Ribas, Silvia Delgado

    2016-05-01

    Regulatory control of medical devices in Cuba is conducted through a system based on the Regulatory Program for Medical Devices as a way to ensure the safety, efficacy, and effectiveness of these technologies, which are in use by the National Health System. This program was launched in 1992, when the Regulations for State Evaluation and Registration of Medical Devices were approved. Its successive stages and the merging of regulatory activities for drugs and medical equipment have meant progress toward stronger, more transparent strategies and greater control of industry and the National Health System. Throughout its course the Cuban program has met with challenges and difficulties that it has addressed by drawing on its own experiences. During the new period, the greatest challenges revolve around ensuring that regulatory systems incorporate scientific evaluation, risk levels, maximum rigor through the use of technical standards, and the implementation of international recommendations, together with the application of the ISO 13485 certification scheme, enhanced market monitoring, and classification of medical devices in accordance with their relevance to the country's national health policies. From the regional standpoint, the greatest challenge lies in working toward regulatory convergence. The Collaborating Centre for the Regulation of Health Technologies will support the proposed regulatory strategy and established regional priorities, in particular in connection with the implementation of actions involving medical devices.

  12. Lifitegrast Ophthalmic Solution 5%: A Review in Dry Eye Disease.

    Science.gov (United States)

    Keating, Gillian M

    2017-02-01

    Lifitegrast is a novel small molecule integrin antagonist that blocks the binding of intercellular adhesion molecule 1 (ICAM-1) to lymphocyte function-associated antigen 1 (LFA-1). Lifitegrast ophthalmic solution 5% (Xiidra™) was recently approved in the USA for the treatment of dry eye disease. The efficacy of lifitegrast ophthalmic solution 5% was compared with vehicle in a 12-week phase 2 study and three 12-week phase 3 studies (OPUS-1, OPUS-2 and OPUS-3) in patients with dry eye disease. Taken as a whole, results of these trials support the treatment effect of lifitegrast ophthalmic solution 5% in improving a symptom of dry eye disease (i.e. the change from baseline to day 84 in the eye dryness visual analogue scale score) and a sign of dry eye disease (i.e. the change from baseline to day 84 in the inferior corneal fluorescein staining score). Lifitegrast ophthalmic solution 5% was generally well tolerated. In conclusion, lifitegrast ophthalmic solution 5% provides a new option for the treatment of dry eye disease.

  13. 76 FR 16292 - Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian Adnexal Mass...

    Science.gov (United States)

    2011-03-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2011-N-0026] Medical Devices; Immunology and Microbiology Devices; Classification of Ovarian... of Food and Drugs, 21 CFR part 866 is amended as follows: PART 866--IMMUNOLOGY AND MICROBIOLOGY...

  14. Safety evaluation in the development of medical devices and combination products

    CERN Document Server

    Gad, Shayne C

    2008-01-01

    Capturing the growth of the global medical device market in recent years, this practical new guide is essential for all who are responsible for ensuring safety in the use and manufacture of medical devices. It has been extensively updated to reflect significant advances, incorporating combination products and helpful case examples of current real-life problems in the field.The Third Edition explores these key current trends:global device marketscontinually advancing technologythe increasing harmonization of device safety regulation worldwideEach aspect of safety evaluation is considered in ter

  15. Bilateral IgG4-related ophthalmic disease: a strong indication for systemic imaging.

    Science.gov (United States)

    Wu, Albert; Andrew, Nicholas H; McNab, Alan A; Selva, Dinesh

    2016-10-01

    To investigate whether bilateral or unilateral IgG4-related ophthalmic disease (IgG4-ROD) is associated with extra-ophthalmic IgG4-related disease (IgG4-RD). Twin-centre retrospective observational case series of biopsy-confirmed IgG4-ROD. Clinical and radiology data were reviewed for laterality of IgG4-ROD and presence of extra-ophthalmic disease. The literature was reviewed for case series of IgG4-ROD. 40 IgG4-ROD cases were identified, with median follow-up of 36 months. At diagnosis of IgG4-ROD, all cases were screened for extra-ophthalmic disease with physical examination and blood testing. Systemic imaging was performed in 20 (50%) cases due to clinical suspicion of extra-ophthalmic disease. Of the 21 unilateral IgG4-ROD cases, 3 (14%) had extra-ophthalmic involvement. Of the 19 bilateral cases, 15 (79%) had extra-ophthalmic involvement. Extra-ophthalmic involvement was strongly associated with bilateral IgG4-ROD (pIgG4-ROD is strongly associated with extra-ophthalmic IgG4-RD. We recommend that imaging of the neck, chest, abdomen and pelvis be performed for all bilateral cases. Systemic imaging should also be considered in unilateral cases as a significant proportion of these patients will also have extra-ophthalmic disease. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Inhaled medication for asthma management: evaluation of how asthma patients, medical students, and doctors use the different devices

    Directory of Open Access Journals (Sweden)

    Muniz Janaína Barbosa

    2003-01-01

    Full Text Available Asthma results from a combination of three essential features: airflow obstruction, hyperresponsiveness of airways to endogenous or exogenous stimuli and inflammation. Inadequacy of the techniques to use different inhalation devices is one of the causes of therapeutic failure. The main purpose of this study was to evaluate how 20 medical students, 36 resident physicians of Internal Medicine/Pediatrics, and 40 asthma patients used three devices for inhalation therapy containing placebo. All patients were followed at the Pulmonary Outpatient Service of Botucatu Medical School and had been using inhaled medication for at least six months. The following devices were evaluated: metered dose inhalers (MDI, dry powder inhalers (DPI, and MDI attached to a spacer device. A single observer applied a protocol containing the main steps necessary to obtain a good inhaler technique to follow and grade the use of different devices. Health care professionals tested all three devices and patients tested only the device being used on their management. MDI was the device best known by doctors and patients. MDI use was associated with errors related to the coordination between inspiration and device activation. Failure to exhale completely before inhalation of the powder was the most frequent error observed with DPI use. In summary, patients did not receive precise instruction on how to use inhaled medication and health care professionals were not well prepared to adequately teach their patients.

  17. Methodological considerations in observational comparative effectiveness research for implantable medical devices: an epidemiologic perspective.

    Science.gov (United States)

    Jalbert, Jessica J; Ritchey, Mary Elizabeth; Mi, Xiaojuan; Chen, Chih-Ying; Hammill, Bradley G; Curtis, Lesley H; Setoguchi, Soko

    2014-11-01

    Medical devices play a vital role in diagnosing, treating, and preventing diseases and are an integral part of the health-care system. Many devices, including implantable medical devices, enter the market through a regulatory pathway that was not designed to assure safety and effectiveness. Several recent studies and high-profile device recalls have demonstrated the need for well-designed, valid postmarketing studies of medical devices. Medical device epidemiology is a relatively new field compared with pharmacoepidemiology, which for decades has been developed to assess the safety and effectiveness of medications. Many methodological considerations in pharmacoepidemiology apply to medical device epidemiology. Fundamental differences in mechanisms of action and use and in how exposure data are captured mean that comparative effectiveness studies of medical devices often necessitate additional and different considerations. In this paper, we discuss some of the most salient issues encountered in conducting comparative effectiveness research on implantable devices. We discuss special methodological considerations regarding the use of data sources, exposure and outcome definitions, timing of exposure, and sources of bias. © The Author 2014. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. [Study on the reform and improvement of the medical device registration system in China].

    Science.gov (United States)

    Wang, Lanming

    2012-11-01

    Based on the theories of the Government Regulation and Administrative Licensure, aiming at the current situations of medical device registration system in China, some policy suggestions for future reform and improvement were provided as follows. (1) change the concepts of medical device registration administration. (2) perfect the regulations of medical device registration administration. (3) reform the medical device review organizational system. (4) Optimize the procedure of review and approval. (5) set up and maintain a professional team of review and approval staff. (6) reinforce the post-marketing supervision of medical devices. (7) foster and bring into play of the role of non-government organizations.

  19. Diquafosol ophthalmic solution for dry eye treatment.

    Science.gov (United States)

    Nakamura, Masatsugu; Imanaka, Takahiro; Sakamoto, Asuka

    2012-07-01

    There has been rapid progress in our understanding of dry eye pathogenesis, as well as the development of improved diagnostic clinical tests. Various types of dry eye treatment drugs have been developed. This review summarizes the basic and clinical research carried out in the development of diquafosol for ophthalmic use. Diquafosol is a dinucleotide, purinoreceptor P2Y(2) receptor agonist. Basic pharmacological studies have shown that it acts on P2Y(2) receptors at the ocular surface, to promote tear and mucin secretion via elevated intracellular Ca(2+) concentrations. Diquafosol also improves tear and mucin secretion in experimental dry eye models. Based on the results of laboratory experiments, the authors conducted a series of clinical studies in patients with dry eye disease. Diquafosol was effective in the treatment of dry eye disease at an optimal dose of 3% six times a day. In comparison to commercially available 0.1% sodium hyaluronate ophthalmic solution, 3% diquafosol ophthalmic solution showed non-inferiority in improving corneal fluorescein staining scores and superiority in improving keratoconjunctival Rose Bengal staining scores. Diquafosol ophthalmic solution has a novel mechanism of action that is characterized by its stimulatory effects on tear and mucin secretion. This drug has the potential to be effective in patients with tear film instability and short break-up time type of dry eye, which are essential factors in dry eye pathogenesis.

  20. 75 FR 70112 - Medical Devices; General and Plastic Surgery Devices; Classification of Non-Powered Suction...

    Science.gov (United States)

    2010-11-17

    .... FDA-2010-N-0513] Medical Devices; General and Plastic Surgery Devices; Classification of Non-Powered... risks. Adverse tissue reaction Material degradation Improper function of suction apparatus (e.g., reflux.... Material degradation Section 8. Stability and Shelf Life. [[Page 70113

  1. Campaign to gather medical devices containing radium: results

    International Nuclear Information System (INIS)

    Pierre, J.P.; Vidal, J.P.; Martin, J.C.; Pasquier, J.L.

    2002-01-01

    Campaign to gather medical devices containing radium: results. On December 1, 1999, at the request of the French Health Ministry, OPRI and ANDRA launched a campaign to gather medical devices containing radium, formerly used in brachytherapy. This campaign addressed a public health issue because of the risks actually involved in a careless handling of these objects. Moreover the growing number of reported scattered radium medical devices in the last few years reinforced the necessity of the campaign. The gathering was initiated by a call of the owners (hospitals, caring centers, retired doctors or their heirs) to a toll free number. OPRI or ANDRA then appreciated the situation urgency. Priority was given to private people because most of them did not have suitable storage facilities. OPRI teams operated according a strict protocol guaranteeing their own safety, proper procedures and compliance with transport regulations for radioactive materials. 517 objects amounting to an activity of 1.32 x 10 11 Bq have been gathered in 90 operations. Properly packaged they were transported to and safely stored at the CEA Saclay site before their permanent storage in the ANDRA facilities. (author)

  2. Drugs and Medical Devices: Adverse Events and the Impact on Women's Health.

    Science.gov (United States)

    Carey, Jennifer L; Nader, Nathalie; Chai, Peter R; Carreiro, Stephanie; Griswold, Matthew K; Boyle, Katherine L

    2017-01-01

    A large number of medications and medical devices removed from the market by the US Food and Drug Administration over the past 4 decades specifically posed greater health risks to women. This article reviews the historical background of sex and gender in clinical research policy and describes several approved drugs and devices targeted for use in women that have caused major morbidity and mortality. The intended population for the medications and devices, population affected, approval process, and the basic and legal actions taken against the medication/drug company are also discussed. It is recognized that women are still at risk for harm from unsafe medications and devices, and continued improvements in legislation that promotes inclusion of sex and gender into the design and analysis of research will improve safety for both men and women. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.

  3. Comparison of corneal safety and intraocular pressure-lowering effect of tafluprost ophthalmic solution with other prostaglandin ophthalmic solutions.

    Science.gov (United States)

    Kumagami, Takeshi; Wakiyama, Harumi; Kusano, Mao; Kajiyama, Ayano; Miura, Yoko; Uematsu, Masafumi; Yoneda, Ai; Kurihara, Junko; Suzuma, Kiyoshi; Kitaoka, Takashi

    2014-05-01

    The benzalkonium chloride (BAK) content of tafluprost ophthalmic solution (Tapros(®): tafluprost) has been reduced to balance corneal safety and preservative effectiveness (old formulation: 0.01%; new formulation: 0.001%). However, no reports have been published on its clinical effect. Therefore, we conducted a clinical research study to compare the safety of BAK-reduced tafluprost on the ocular surface with other prostaglandin ophthalmic solutions. This clinical study included 28 glaucoma patients (28 eyes) with a treatment history of latanoprost ophthalmic solution (Xalatan(®)) or travoprost ophthalmic solution (Travatan Z(®)), who presented with corneal epithelial disorders. The subjects were switched to BAK-reduced tafluprost, and its effect on the ocular surface was examined after 1 and 2 months of treatment [using fluorescein staining score, hyperemia, tear film breakup time, and intraocular pressure (IOP) lowering]. In all analyzed subjects (N=27), the fluorescein staining score was significantly improved after switching to BAK-reduced tafluprost (P<0.0001). Conversely, the IOP-lowering effect was not notably changed. The subjects switched from latanoprost (n=10) showed significant improvement in fluorescein staining score (P<0.05) as well as in IOP lowering (P<0.01). The subjects switched from travoprost (n=17) also showed significant improvement in fluorescein staining score (P<0.001), but without a significant change in IOP lowering. Tafluprost with reduced BAK has potential as a superior antiglaucoma drug, not only for its IOP-lowering effect, but also for its good corneal safety profile.

  4. 76 FR 71982 - Advancing Regulatory Science for Highly Multiplexed Microbiology/Medical Countermeasure Devices...

    Science.gov (United States)

    2011-11-21

    ... Multiplexed Microbiology Devices: Their clinical application and public health/clinical needs; inclusion of...] Advancing Regulatory Science for Highly Multiplexed Microbiology/ Medical Countermeasure Devices; Public... Multiplexed Microbiology/ Medical Countermeasure Devices'' that published in the Federal Register of August 8...

  5. Electromagnetic compatibility of WLAN adapters with life-supporting medical devices.

    Science.gov (United States)

    Calcagnini, G; Mattei, E; Censi, F; Triventi, M; Lo Sterzo, R; Marchetta, E; Bartolini, P

    2011-05-01

    This paper investigates the electromagnetic compatibility of 45 critical care medical devices (infusion pumps, defibrillators, monitors, lung ventilators, anesthesia machines and external pacemakers) with various types of wireless local area network (WLAN, IEEE 802.11 b/g, 2.45 GHz, 100 mW) adapters. Interference is evaluated by performing ad-hoc tests according to the ANSI C63.18 recommended practice. The behavior of the devices during the tests was monitored using patient simulators/device testers specific for each device class. Electromagnetic interference cases were observed in three of 45 devices at a maximum distance of 5 cm. In two cases the interference caused malfunctions that may have clinical consequences for the patient. The authors' findings show that the use of these wireless local area network adapters can be considered reasonably safe, although interference may occur if they are operated at very close distance (<10 cm) to the medical devices.

  6. 77 FR 6028 - Taxable Medical Devices

    Science.gov (United States)

    2012-02-07

    ... sold as part of an x-ray system. Commentators also requested information on the tax treatment of..., mitigation, treatment, or prevention of disease; or intended to affect the structure or any function of the... subject to an IDE is not a ``taxable medical device'' under the proposed regulations. VI. Dental...

  7. 78 FR 33849 - Battery-Powered Medical Devices Workshop: Challenges and Opportunities; Public Workshop; Request...

    Science.gov (United States)

    2013-06-05

    ... after the public workshop on the Internet at http://www.fda.gov/MedicalDevices/NewsEvents/Workshops..., compact, and mobile, the number of battery-powered medical devices will continue to increase. While many...] Battery-Powered Medical Devices Workshop: Challenges and Opportunities; Public Workshop; Request for...

  8. Comparison of systemic absorption between ofloxacin ophthalmic in situ gels and ofloxacin conventional ophthalmic solutions administration to rabbit eyes by HPLC-MS/MS.

    Science.gov (United States)

    Li, Jiawei; Zhao, Hainan; Okeke, Chukwunweike Ikechukwu; Li, Lin; Liu, Zhidong; Yin, Zhongpeng; Zhuang, Pengwei; Sun, Jingtong; Wu, Tao; Wang, Meng; Li, Nan; Pi, Jiaxin; Zhang, Qian; Zhang, Rui; Ma, Li; Pang, Xiaochen; Liu, Zhanbiao; Zhang, Li; Fan, Lili

    2013-06-25

    In recent years, many pharmaceutical scientists have focused on developing the in situ gel-forming systems to overcome the poor bioavailability and therapeutic response exhibited by conventional ophthalmic solutions due to rapid pre-corneal elimination of the drug. The present work was to compare the systemic absorptions of ophthalmic ofloxacin in situ gel with the conventional ofloxacin eye drop after topical instillation to rabbit eyes by HPLC-MS/MS method and also determine the relative contribution of the nasal and the conjunctival mucosae to systemic ofloxacin absorption following topical instillation. The systemic AUC, Cmax, Tmax and Ke for ophthalmic in situ gel and ophthalmic solution after ocular instillation were 202.63±118.85 and 202.25±57.74 ng mL(-1) h, 54.22±28.31 and 48.4±25.97 ng mL(-1), 1.08±0.20 and 1.25±0.88 h, 0.0576±0.0207 and 0.0388±0.0248, respectively. And the values for the ratios of the AUC of anterior chamber of rabbit eye to blood plasma, AUCac/AUCpl, for ofloxacin conventional eye drop and in situ gel were 0.25 and 0.52, respectively. Statistic results showed that there was no significant difference in systemic absorption between the test groups and the reference groups (P>0.05) as both formulations have an AUCsa/AUCpl of 0.35. Therefore, the ophthalmic in situ gel may not decrease the drugs systemic absorption when administered in an equivalent dose as ophthalmic solutions into the rabbit eyes. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. 75 FR 68972 - Medical Devices; General and Plastic Surgery Devices; Classification of Tissue Adhesive With...

    Science.gov (United States)

    2010-11-10

    .... FDA-2010-N-0512] Medical Devices; General and Plastic Surgery Devices; Classification of Tissue... running to unintended areas, etc. B. Wound dehiscence C. Adverse tissue reaction and chemical burns D..., Clinical Studies, Labeling. Adverse tissue reaction and chemical Biocompatibility Animal burns. Testing...

  10. 77 FR 32644 - Medical Devices; Exemption From Premarket Notification: Wheelchair Elevator

    Science.gov (United States)

    2012-06-01

    ...] Medical Devices; Exemption From Premarket Notification: Wheelchair Elevator AGENCY: Food and Drug... elevator devices commonly known as inclined platform lifts and vertical platform lifts. These devices are... behalf of Bruno Independent Living Aids, Inc., for wheelchair elevator devices (commonly known as...

  11. Views of patients and professionals about electronic multicompartment medication devices: a qualitative study.

    Science.gov (United States)

    Hall, Jill; Bond, Christine; Kinnear, Moira; McKinstry, Brian

    2016-10-17

    To explore the perceived acceptability, advantages and disadvantages of electronic multicompartment medication devices. Qualitative study using 8 focus groups and 10 individual semistructured interviews. Recordings were transcribed and analysed thematically. Strategies were employed to ensure the findings were credible and trustworthy. Community pharmacists (n=11), general practitioners (n=9), community nurses (n=12) and social care managers (n=8) were recruited from the National Health Service (NHS) and local authority services. Patients (n=15) who were current conventional or electronic multicompartment medication device users or had medication adherence problems were recruited from community pharmacies. 3 informal carers participated. Electronic multicompartment medication devices which prompt the patient to take medication may be beneficial for selected individuals, particularly those with cognitive impairment, but who are not seriously impaired, provided they have a good level of dexterity. They may also assist individuals where it is important that medication is taken at fixed time intervals. These are likely to be people who are being supported to live alone. No single device suited everybody; smaller/lighter devices were preferred but their usefulness was limited by the small number/size of storage compartments. Removing medications was often challenging. Transportability was an important factor for patients and carers. A carer's alert if medication is not taken was problematic with multiple barriers to implementation and no consensus as to who should receive the alert. There was a lack of enthusiasm among professionals, particularly among pharmacists, due to concerns about responsibility and funding for devices as well as ensuring devices met regulatory standards for storage and labelling. This study provides indicators of which patients might benefit from an electronic multicompartment medication device as well as the kinds of features to consider when

  12. Left to their own devices: medical learners' use of mobile technologies.

    Science.gov (United States)

    Ellaway, Rachel H; Fink, Patricia; Graves, Lisa; Campbell, Alanna

    2014-02-01

    Although many medical learners and teachers are using mobile technologies within medical education, there has been little evidence presented describing how they use mobile devices across a whole curriculum. The Northern Ontario School of Medicine (NOSM) introduced a new mobile device program in 2010. Incoming undergraduate medical learners received a laptop and an iPad and learners entering year three of the four-year program received a laptop and an iPhone. A survey was sent to all learners to gather information on their use of and attitudes toward these devices. A combination of quantitative and qualitative methods was used to analyze the data and to generate a series of themes that synthesized student behaviors, perceptions and attitudes. Context and learner autonomy were found to be important factors with learners using multiple devices for different purposes and adopting strategic approaches to learning using these devices. The expectation that school-issued devices would be regularly and enthusiastically used to replace more traditional study media was not reflected in practice. Learners' approaches to using mobile devices are heterogeneous as is the extent to which they use them. Learners adapt their use of mobile devices to the learning cultures and contexts they find themselves in.

  13. Advancing medical device innovation through collaboration and coordination of structured data capture pilots: Report from the Medical Device Epidemiology Network (MDEpiNet) Specific, Measurable, Achievable, Results-Oriented, Time Bound (SMART) Think Tank.

    Science.gov (United States)

    Reed, Terrie L; Drozda, Joseph P; Baskin, Kevin M; Tcheng, James; Conway, Karen; Wilson, Natalia; Marinac-Dabic, Danica; Heise, Theodore; Krucoff, Mitchell W

    2017-12-01

    The Medical Device Epidemiology Network (MDEpiNet) is a public private partnership (PPP) that provides a platform for collaboration on medical device evaluation and depth of expertise for supporting pilots to capture, exchange and use device information for improving device safety and protecting public health. The MDEpiNet SMART Think Tank, held in February, 2013, sought to engage expert stakeholders who were committed to improving the capture of device data, including Unique Device Identification (UDI), in key electronic health information. Prior to the Think Tank there was limited collaboration among stakeholders beyond a few single health care organizations engaged in electronic capture and exchange of device data. The Think Tank resulted in what has become two sustainable multi-stakeholder device data capture initiatives, BUILD and VANGUARD. These initiatives continue to mature within the MDEpiNet PPP structure and are well aligned with the goals outlined in recent FDA-initiated National Medical Device Planning Board and Medical Device Registry Task Force white papers as well as the vision for the National Evaluation System for health Technology.%. Published by Elsevier Inc.

  14. Possibilities of radiation sterilization for re-usage of medical devices in the medical management

    International Nuclear Information System (INIS)

    Tabei, Masae; Kudo, Hisaaki; Katsumura, Yosuke

    2004-01-01

    The rule for re-usage of medical single-use devices was established in US in 2000 based on the concept of Managed Care (total management of medicare on cost, quality and patients' satisfaction) and 20-30% of those devices are re-used at present. The re-usage is conducted in not only US but also Canada, Denmark, UK, India, China etc. Standing on the viewpoint, this paper described and discussed the possibility of re-usage of the single-use devices now prohibited in Japan, possible re-sterilization, possible re-usage of hollow fiber-type hemodialyzer following γ-ray sterilization with consideration for D-values against bacteria and viruses, cost estimation of electron beam sterilization for re-usage, and radiation sterilization of waste water and plastic materials. Radiation sterilization for re-usage of medical devices was concluded possible if their materials and records for their usage processes are proper, and should be conducted in a large scale after sufficient examinations by industries/government/academia. (N.I.)

  15. Third-year medical students' knowledge of privacy and security issues concerning mobile devices.

    Science.gov (United States)

    Whipple, Elizabeth C; Allgood, Kacy L; Larue, Elizabeth M

    2012-01-01

    The use of mobile devices are ubiquitous in medical-care professional settings, but information on privacy and security concerns of mobile devices for medical students is scarce. To gain baseline information about third-year medical students' mobile device use and knowledge of privacy and security issues concerning mobile devices. We surveyed 67 third-year medical students at a Midwestern university on their use of mobile devices and knowledge of how to protect information available through mobile devices. Students were also presented with clinical scenarios to rate their level of concern in regards to privacy and security of information. The most used features of mobile devices were: voice-to-voice (100%), text messaging (SMS) (94%), Internet (76.9%), and email (69.3%). For locking of one's personal mobile phone, 54.1% never physically lock their phone, and 58% never electronically lock their personal PDA. Scenarios considering definitely privacy concerns include emailing patient information intact (66.7%), and posting de-identified information on YouTube (45.2%) or Facebook (42.2%). As the ease of sharing data increases with the use of mobile devices, students need more education and training on possible privacy and security risks posed with mobile devices.

  16. Ophthalmic Drug Dosage Forms: Characterisation and Research Methods

    OpenAIRE

    Baranowski, Przemysław; Karolewicz, Bożena; Gajda, Maciej; Pluta, Janusz

    2014-01-01

    This paper describes hitherto developed drug forms for topical ocular administration, that is, eye drops, ointments, in situ gels, inserts, multicompartment drug delivery systems, and ophthalmic drug forms with bioadhesive properties. Heretofore, many studies have demonstrated that new and more complex ophthalmic drug forms exhibit advantage over traditional ones and are able to increase the bioavailability of the active substance by, among others, reducing the susceptibility of drug forms to...

  17. Low power signal processing electronics for wearable medical devices.

    Science.gov (United States)

    Casson, Alexander J; Rodriguez-Villegas, Esther

    2010-01-01

    Custom designed microchips, known as Application Specific Integrated Circuits (ASICs), offer the lowest possible power consumption electronics. However, this comes at the cost of a longer, more complex and more costly design process compared to one using generic, off-the-shelf components. Nevertheless, their use is essential in future truly wearable medical devices that must operate for long periods of time from physically small, energy limited batteries. This presentation will demonstrate the state-of-the-art in ASIC technology for providing online signal processing for use in these wearable medical devices.

  18. Cerebral Angiographic Findings of Cosmetic Facial Filler-related Ophthalmic and Retinal Artery Occlusion.

    Science.gov (United States)

    Kim, Yong-Kyu; Jung, Cheolkyu; Woo, Se Joon; Park, Kyu Hyung

    2015-12-01

    Cosmetic facial filler-related ophthalmic artery occlusion is rare but is a devastating complication, while the exact pathophysiology is still elusive. Cerebral angiography provides more detailed information on blood flow of ophthalmic artery as well as surrounding orbital area which cannot be covered by fundus fluorescein angiography. This study aimed to evaluate cerebral angiographic features of cosmetic facial filler-related ophthalmic artery occlusion patients. We retrospectively reviewed cerebral angiography of 7 patients (4 hyaluronic acid [HA] and 3 autologous fat-injected cases) showing ophthalmic artery and its branches occlusion after cosmetic facial filler injections, and underwent intra-arterial thrombolysis. On selective ophthalmic artery angiograms, all fat-injected patients showed a large filling defect on the proximal ophthalmic artery, whereas the HA-injected patients showed occlusion of the distal branches of the ophthalmic artery. Three HA-injected patients revealed diminished distal runoff of the internal maxillary and facial arteries, which clinically corresponded with skin necrosis. However, all fat-injected patients and one HA-injected patient who were immediately treated with subcutaneous hyaluronidase injection showed preserved distal runoff of the internal maxillary and facial arteries and mild skin problems. The size difference between injected materials seems to be associated with different angiographic findings. Autologous fat is more prone to obstruct proximal part of ophthalmic artery, whereas HA obstructs distal branches. In addition, hydrophilic and volume-expansion property of HA might exacerbate blood flow on injected area, which is also related to skin necrosis. Intra-arterial thrombolysis has a limited role in reconstituting blood flow or regaining vision in cosmetic facial filler-associated ophthalmic artery occlusions.

  19. Stakeholder challenges in purchasing medical devices for patient safety.

    Science.gov (United States)

    Hinrichs, Saba; Dickerson, Terry; Clarkson, John

    2013-03-01

    This study identifies the stakeholders who have a role in medical device purchasing within the wider system of health-care delivery and reports on their particular challenges to promote patient safety during purchasing decisions. Data was collected through observational work, participatory workshops, and semi-structured qualitative interviews, which were analyzed and coded. The study takes a systems-based and engineering design approach to the study. Five hospitals took part in this study, and the participants included maintenance, training, clinical end-users, finance, and risk departments. The main stakeholders for purchasing were identified to be staff from clinical engineering (Maintenance), device users (Clinical), device trainers (Training), and clinical governance for analyzing incidents involving devices (Risk). These stakeholders display varied characteristics in terms of interpretation of their own roles, competencies for selecting devices, awareness and use of resources for purchasing devices, and attitudes toward the purchasing process. The role of "clinical engineering" is seen by these stakeholders to be critical in mediating between training, technical, and financial stakeholders but not always recognized in practice. The findings show that many device purchasing decisions are tackled in isolation, which is not optimal for decisions requiring knowledge that is currently distributed among different people within different departments. The challenges expressed relate to the wider system of care and equipment management, calling for a more systemic view of purchasing for medical devices.

  20. [Software as medical devices/medical apps : Tasks, requirements, and experiences from the point of view of a competent authority].

    Science.gov (United States)

    Terhechte, Arno

    2018-03-01

    Software can be classified as a medical device according to the Medical Device Directive 93/42/EEC. The number of software products and medical apps is continuously increasing and so too is the use in health institutions (e. g., in hospitals and doctors' surgeries) for diagnosis and therapy.Different aspects of standalone software and medical apps from the perspective of the authority responsible are presented. The quality system implemented to establish a risk-based systematic inspection and supervision of manufacturers is discussed. The legal framework, as well as additional standards that are the basis for inspection, are outlined. The article highlights special aspects that occur during inspection like verification of software and interfaces, and the clinical evaluation of software. The Bezirksregierung, as the local government authority responsible in North Rhine-Westphalia, is also in charge of inspection of health institutions. Therefore this article is not limited to the manufacturers placing the software on the market, but in addition it describes the management and use of software as a medical device in hospitals.The future legal framework, the Medical Device Regulation, will strengthen the requirements and engage notified bodies more than today in the conformity assessment of software as a medical device.Manufacturers, health institutions, notified bodies and the authorities responsible are in charge of intensifying their efforts towards software as a medical device. Mutual information, improvement of skills, and inspections will lead to compliance with regulatory requirements.

  1. ANAESTHESIA FOR OPHTHALMIC SURGICAL PROCEDURES

    African Journals Online (AJOL)

    Objective: To review factors influencing the choice of anaesthesia for ophthalmic surgical procedures. ... as risk associated with general anaesthesia (8) they are more .... Wilson ME, Pandey SK, Thakur J. Paediatric cataract blindness in the ...

  2. Research on dose setting for radiation sterilization of medical device

    International Nuclear Information System (INIS)

    Zhang Tongcheng; Liu Qingfang; Zhong Hongliang; Mi Zhisu; Wang Chunlei; Jiang Jianping

    2002-01-01

    Objective: To establish the radiation sterilization dose for medical devices using data of bioburden on the medical device. Methods: Firstly determination of recovery ratio and correction coefficient of the microbiological test method was used according to ISO11737 standard, then determination of bioburden on the products, finally the dose setting was completed based on the Method 1 in ISO11137 standard. Results: Fifteen kinds of medical devices were tested. Bioburden range was from 8.6-97271.2 CFU/device, recovery ration range 54.6%-100%, correction co-efficiency range 1.00-1.83, D 10 distribution from 1.40 to 2.82 kGy, verification dose (dose at SAL = 10 -2 ) range 5.1-17.6 kGy and sterilization dose (dose at SAL 10 -6 ) range 17.5-32.5 kGy. Conclusion: One hundred samples of each kind of product were exposed to the pre-determined verification dose and then the sterility test was performed. Each sterility test showed positive number was not greater than two. This indicated that the sterilization dose established for each kind of product was statistically acceptable

  3. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    International Nuclear Information System (INIS)

    Ayaz, Tunahan; Akansel, Gur.; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-01-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia

  4. 77 FR 32642 - Medical Devices; Exemption From Premarket Notification: Powered Patient Transport

    Science.gov (United States)

    2012-06-01

    ...] Medical Devices; Exemption From Premarket Notification: Powered Patient Transport AGENCY: Food and Drug... received a petition requesting exemption from the premarket notification requirements for powered patient... necessary to provide a reasonable assurance of safety and effectiveness. Under the Medical Device Amendments...

  5. 76 FR 14414 - Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-03-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES [Docket No. FDA-2011-N-0002] Microbiology Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug Administration, HHS... and Drug Administration (FDA). The meeting will be open to the public. Name of Committee: Microbiology...

  6. Medical Device Plug-and-Play Interoperability Standards and Technology Leadership

    Science.gov (United States)

    2010-10-01

    American Telemedicine Association), we demonstrated how continuous monitoring of the patient’s SpO2 and respiratory rate could detect the onset of...designed to monitor sepsis infection sounded its alarm continually, day and night. The device was built with an innovative algorithm to detect sepsis, but...transport Figure 3. This medical device has misread its sensors and inserted false data into patient’s permanent medical record. SPECIal FEaTuRE October

  7. 21 CFR 886.4610 - Ocular pressure applicator.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4610 Ocular pressure applicator. (a... bulb, a dial indicator, a band, and bellows, intended to apply pressure on the eye in preparation for...

  8. 21 CFR 801.16 - Medical devices; Spanish-language version of certain required statements.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices; Spanish-language version of....16 Medical devices; Spanish-language version of certain required statements. If devices restricted to prescription use only are labeled solely in Spanish for distribution in the Commonwealth of Puerto Rico where...

  9. Health Care: Reprocessed Medical Single-Use Devices in DoD

    National Research Council Canada - National Science Library

    2002-01-01

    ... for decontamination and resterilization. The emergence of new materials and sterilization methods, and the increasing costs of health care, resulted in the development of medical single-use devices and the practice of reprocessing the devices...

  10. Management information system of medical equipment using mobile devices

    Science.gov (United States)

    Núñez, C.; Castro, D.

    2011-09-01

    The large numbers of technologies currently incorporated into mobile devices transform them into excellent tools for capture and to manage the information, because of the increasing computing power and storage that allow to add many miscellaneous applications. In order to obtain benefits of these technologies, in the biomedical engineering field, it was developed a mobile information system for medical equipment management. The central platform for the system it's a mobile phone, which by a connection with a web server, it's capable to send and receive information relative to any medical equipment. Decoding a type of barcodes, known as QR-Codes, the management process is simplified and improved. These barcodes identified the medical equipments in a database, when these codes are photographed and decoded with the mobile device, you can access to relevant information about the medical equipment in question. This Project in it's actual state is a basic support tool for the maintenance of medical equipment. It is also a modern alternative, competitive and economic in the actual market.

  11. 21 CFR 524.1484e - Neomycin sulfate and polymyxin B sulfate ophthalmic solution.

    Science.gov (United States)

    2010-04-01

    ... ophthalmic solution. 524.1484e Section 524.1484e Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS § 524.1484e Neomycin sulfate and polymyxin B sulfate ophthalmic solution. (a...

  12. Regulatory Science in Practice (Pharmaceuticals and Medical Devices Agency).

    Science.gov (United States)

    Hojo, Taisuke

    2017-01-01

    Review, safety, and relief services of the Pharmaceuticals and Medical Devices Agency are primarily focused on scientifically evaluating pharmaceuticals, medical devices, and cellular and tissue-based products referring to their quality, efficacy, and safety, which requires a variety of scientific knowledge and methods. Pharmaceutical regulation should be established based on the most advanced scientific expertise at all times. In order to evaluate products that use cutting-edge technology such as induced pluripotent stem cells and information and communication technology adequately, since fiscal year 2012 the Science Committee has been established as a platform to exchange opinions among members from top-ranking domestic and international academia and to enhance personnel exchanges through the Initiative to Facilitate Development of Innovative Drugs. In addition, the Regulatory Science Center will be established in 2018 to increase the integrity of our services for product reviews and safety measures. In particular, requiring electronic data submissions for clinical trial applications followed by an advanced approach to analysis should not only enhance the quality of reviews of individual products but should also support the development of pharmaceuticals and medical devices by providing pharmaceutical affairs consultations on research and development strategies with various guidelines based on new insights resulting from product-bridging data analysis. Moreover, a database including electronic health records with comprehensive medical information collected mainly from 10 cooperating medical institutions will be developed with the aim of developing safety measures in a more timely manner using methods of pharmacoepidemiological analysis.

  13. 31 CFR 595.513 - In-kind donations of medicine, medical devices, and medical services.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false In-kind donations of medicine...-kind donations of medicine, medical devices, and medical services. (a) Effective July 6, 2006, nongovernmental organizations that are U.S. persons are authorized to provide in-kind donations of medicine...

  14. Neuro-ophthalmic and clinical characteristics of brain tumours in a ...

    African Journals Online (AJOL)

    Background: Anecdotally, increasing number of patients are seen at Korle Bu Teaching Hospital (KBTH) with brain tumour. Neuro-ophthalmic symptoms and signs may help in timely diagnosis and intervention. Objective: To evaluate the neuro-ophthalmic and clinical characteristics of brain tumour in patients presenting at a ...

  15. Pricing and reimbursement of drugs and medical devices in Hungary.

    Science.gov (United States)

    Gulácsi, L; Dávid, T; Dózsa, Cs

    2002-01-01

    Similarly to other countries of Central and Eastern Europe, Hungary has witnessed massive diffusion of healthcare technology such as drugs and medical devices since 1990. While substantial new pharmaceuticals, medical devices, and procedures have been liberalized, there has been no proper evaluation or training in their use. Healthcare providers have come to find themselves as entrepreneurs in private practice, while patients are acquiring an increasing awareness as customers of healthcare,demanding services in return for their taxes and contributions. This has led to extremely irrational patterns of investment in technology, with most an obvious waste of resources, while leaving basic needs unmet. Both the National Health Insurance Fund and the Ministry of Finance believe that the current pharmaceutical and medical device bill is too high. However, introducing a more transparent and flexible pricing and reimbursement framework may enable a more efficient allocation of the limited resources to be achieved.

  16. Ophthalmic artery color Doppler ultrasonography in mild-to-moderate preeclampsia

    Energy Technology Data Exchange (ETDEWEB)

    Ayaz, Tunahan; Akansel, Gur. E-mail: gakansel@superonline.com; Hayirlioglu, Alper; Arslan, Arzu; Suer, Necdet; Kuru, Ihsan

    2003-06-01

    Objective: To evaluate the hemodynamic changes in mild-moderate preeclampsia using ophthalmic artery Doppler ultrasonography technique. Methods: Ophthalmic artery pulsatility and resistivity indices were calculated in 30 mild-moderate preeclamptic women and 30 normotensive gravid women of matched gestational age. Student's t-test was performed to test the significance of difference. Results: Both indices of peripheral resistance were found to be significantly lower in the ophthalmic arteries of mild-moderately preeclamptic women than those measured in normotensive gravid women at similar stage of pregnancy. In a small number patients whose disease progressed to severe preeclampsia, both indices increased. Conclusion: In patients with mild-moderate preeclampsia, ophthalmic artery color Doppler ultrasonography detects hemodynamic changes that are not present in normotensive gravid women. Reversal of Doppler patterns in a small number of patients with progressive disease supports the hypotheses suggesting the presence of early vasodilation and late vasospasm in the etiology of preeclampsia.

  17. 75 FR 1395 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2010-01-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2009-N-0606] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice...) is announcing an amendment to the notice of a meeting of the General and Plastic Surgery Devices...

  18. Towards automated assistance for operating home medical devices.

    Science.gov (United States)

    Gao, Zan; Detyniecki, Marcin; Chen, Ming-Yu; Wu, Wen; Hauptmann, Alexander G; Wactlar, Howard D

    2010-01-01

    To detect errors when subjects operate a home medical device, we observe them with multiple cameras. We then perform action recognition with a robust approach to recognize action information based on explicitly encoding motion information. This algorithm detects interest points and encodes not only their local appearance but also explicitly models local motion. Our goal is to recognize individual human actions in the operations of a home medical device to see if the patient has correctly performed the required actions in the prescribed sequence. Using a specific infusion pump as a test case, requiring 22 operation steps from 6 action classes, our best classifier selects high likelihood action estimates from 4 available cameras, to obtain an average class recognition rate of 69%.

  19. Recent advances in medical device triage technologies for chemical, biological, radiological, and nuclear events.

    Science.gov (United States)

    Lansdowne, Krystal; Scully, Christopher G; Galeotti, Loriano; Schwartz, Suzanne; Marcozzi, David; Strauss, David G

    2015-06-01

    In 2010, the US Food and Drug Administration (Silver Spring, Maryland USA) created the Medical Countermeasures Initiative with the mission of development and promoting medical countermeasures that would be needed to protect the nation from identified, high-priority chemical, biological, radiological, or nuclear (CBRN) threats and emerging infectious diseases. The aim of this review was to promote regulatory science research of medical devices and to analyze how the devices can be employed in different CBRN scenarios. Triage in CBRN scenarios presents unique challenges for first responders because the effects of CBRN agents and the clinical presentations of casualties at each triage stage can vary. The uniqueness of a CBRN event can render standard patient monitoring medical device and conventional triage algorithms ineffective. Despite the challenges, there have been recent advances in CBRN triage technology that include: novel technologies; mobile medical applications ("medical apps") for CBRN disasters; electronic triage tags, such as eTriage; diagnostic field devices, such as the Joint Biological Agent Identification System; and decision support systems, such as the Chemical Hazards Emergency Medical Management Intelligent Syndromes Tool (CHEMM-IST). Further research and medical device validation can help to advance prehospital triage technology for CBRN events.

  20. 31 CFR 594.515 - In-kind donations of medicine, medical devices, and medical services.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false In-kind donations of medicine....515 In-kind donations of medicine, medical devices, and medical services. (a) Effective July 6, 2006, nongovernmental organizations that are U.S. persons are authorized to provide in-kind donations of medicine...

  1. 31 CFR 597.511 - In-kind donations of medicine, medical devices, and medical services.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 3 2010-07-01 2010-07-01 false In-kind donations of medicine... Licensing Policy § 597.511 In-kind donations of medicine, medical devices, and medical services. (a... incident to the provision by nongovernmental organizations that are U.S. persons of in-kind donations of...

  2. ANSTO and CSIRO: supporting the medical devices and sensors industry in Australia

    International Nuclear Information System (INIS)

    Triani, Gerry; Doe, Simon

    2005-01-01

    The Australian Nuclear Science and Technology Organisation (ANSTO) and the Commonwealth Scientific and Industrial Research Organisation (CSIRO) have provided support to the Medical Devices and Sensors Industry in Australia for many years. In particular the Institute of Materials and Engineering Science at ANSTO and CSIRO Manufacturing and Infrastructure Technology have worked independently and jointly on a number of projects to provide technical services and support to small to medium sized companies. A recent venture to capture their capabilities in the WTIA's Medical Devices and Sensors Industry Sectoral Project, part of the WTIA National Diffusion Networks Project, has produced substantial technical and financial gains for its participants. The aim of this article is to highlight the infrastructure and capabilities that ANSTO and CSIRO can provide to component manufacturers and industry clusters that offer a range of manufacturing processes needed for medical devices and sensors. Several case studies illustrate how ANSTO and CSIRO have provided support to the medical devices industry

  3. Sterilization and reprocessing of materials and medical devices--reusability.

    Science.gov (United States)

    Jayabalan, M

    1995-07-01

    Problems associated with reprocessing of disposable medical devices such as hemodialysers with resterilization for reuse and changes in material properties with resterilization of polymeric (PVC, polypropylene, polyester, polycarbonate) materials intended for development of disposable devices are reviewed. Reprocessing of hospital supplies, polystyrene microtiter plate and angiographic catheter for reuse is also discussed.

  4. Home Healthcare Medical Devices: Infusion Therapy - Getting the Most Out of Your Pump

    Science.gov (United States)

    ... Medical Procedures Home Health and Consumer Devices Brochure - Home Healthcare Medical Devices: Infusion Therapy - Getting the Most ... if needed. What is the role of your home healthcare provider and supplier in your infusion therapy? ...

  5. 76 FR 42713 - General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of...

    Science.gov (United States)

    2011-07-19

    ...] General and Plastic Surgery Devices Panel of the Medical Devices Advisory Committee; Amendment of Notice... announcing an amendment to the notice of meeting of the General and Plastic Surgery Devices Panel of the... INFORMATION: In the Federal Register of July 7, 2011, FDA announced that a meeting of the General and Plastic...

  6. OR.NET: a service-oriented architecture for safe and dynamic medical device interoperability.

    Science.gov (United States)

    Kasparick, Martin; Schmitz, Malte; Andersen, Björn; Rockstroh, Max; Franke, Stefan; Schlichting, Stefan; Golatowski, Frank; Timmermann, Dirk

    2018-02-23

    Modern surgical departments are characterized by a high degree of automation supporting complex procedures. It recently became apparent that integrated operating rooms can improve the quality of care, simplify clinical workflows, and mitigate equipment-related incidents and human errors. Particularly using computer assistance based on data from integrated surgical devices is a promising opportunity. However, the lack of manufacturer-independent interoperability often prevents the deployment of collaborative assistive systems. The German flagship project OR.NET has therefore developed, implemented, validated, and standardized concepts for open medical device interoperability. This paper describes the universal OR.NET interoperability concept enabling a safe and dynamic manufacturer-independent interconnection of point-of-care (PoC) medical devices in the operating room and the whole clinic. It is based on a protocol specifically addressing the requirements of device-to-device communication, yet also provides solutions for connecting the clinical information technology (IT) infrastructure. We present the concept of a service-oriented medical device architecture (SOMDA) as well as an introduction to the technical specification implementing the SOMDA paradigm, currently being standardized within the IEEE 11073 service-oriented device connectivity (SDC) series. In addition, the Session concept is introduced as a key enabler for safe device interconnection in highly dynamic ensembles of networked medical devices; and finally, some security aspects of a SOMDA are discussed.

  7. The assessment of visually impaired persons working capacities using electrophysiological and ophthalmic ergonomics methods

    Directory of Open Access Journals (Sweden)

    M. I. Razumovsky

    2014-07-01

    Full Text Available Aim was to analyze working capacities of visually impaired persons by means of complex electrophysiological and ophthalmic ergonomics eye examination.Materials and methods. Standard clinical ophthalmologic examination (visual acuity measurement, refractometry, biomicroscopy, ophthalmoscopy as well as electrophysiological (electrooculography, electrical sensitivity of the eye, critical flicker fusion frequency and ophthalmic ergonomics tests (accommodation measurement, professional testing using automated system «Proftest-1» were performed.Results. Complex electrophysiological and ophthalmic ergonomics tests were performed in 20 visually impaired persons. Their results revealed direct correlation between electrophysiological and ophthalmic ergonomics indices.Conclusion. Working capacities of visually impaired persons can be assessed reliably using complex electrophysiological and ophthalmic ergonomics eye examination only.

  8. The assessment of visually impaired persons working capacities using electrophysiological and ophthalmic ergonomics methods

    Directory of Open Access Journals (Sweden)

    M. I. Razumovsky

    2014-01-01

    Full Text Available Aim was to analyze working capacities of visually impaired persons by means of complex electrophysiological and ophthalmic ergonomics eye examination.Materials and methods. Standard clinical ophthalmologic examination (visual acuity measurement, refractometry, biomicroscopy, ophthalmoscopy as well as electrophysiological (electrooculography, electrical sensitivity of the eye, critical flicker fusion frequency and ophthalmic ergonomics tests (accommodation measurement, professional testing using automated system «Proftest-1» were performed.Results. Complex electrophysiological and ophthalmic ergonomics tests were performed in 20 visually impaired persons. Their results revealed direct correlation between electrophysiological and ophthalmic ergonomics indices.Conclusion. Working capacities of visually impaired persons can be assessed reliably using complex electrophysiological and ophthalmic ergonomics eye examination only.

  9. El Centro de Cardioestimuladores del Uruguay. CCC Medical Devices

    Directory of Open Access Journals (Sweden)

    Pablo Darscht

    2011-05-01

    Full Text Available Estudio de caso del Centro de Cardioestimuladores del Uruguay - CCC Medical Devices preparado a solicitud de Ingenio en el marco del proyecto financiado por la Iniciativa para Incubadoras de InfoDev - Grupo Banco Mundial. Este estudio detalla los pasos seguidos por una empresa nacional con un fuerte factor de innovación y los cambios producidos en el entorno de los negocios de la empresa. El comienzo de una pequeña empresa de marcapasos que tras pasar por diferentes etapas hoy gana mercados en el área de ingeniería para dispositivos médicos para diferentes empresas de investigación biomédica a nivel internacional.AbstractCase study of the Centro de Cardioestimuladores del Uruguay - CCC Medical Devices prepared on behalf of Ingenio within the project financed by de Incubator Initiative of InfoDev-World Bank Group. This study refers to the steps followed by a highly innovative local company and to the changes in its business environment. The start up of a small pacemakers company that after going through different stages is presently increasing its market share in the area of engineering of medical devices for biomedic research companies worldwide.

  10. 76 FR 80949 - Request for Nominations for Voting Members on Public Advisory Panels or Committees

    Science.gov (United States)

    2011-12-27

    .... Orthopedic and Rehabilitation Devices Panel. Jamie Waterhouse, Center for Devices Circulatory System Devices... Advisory Committee--Neurosurgeons (cerebrovascular and pediatric), neurologists (stroke, pediatric, pain... ophthalmic clinical trials. Orthopaedic and 2 September 1, 2012. Rehabilitation Devices Panel of the Medical...

  11. Current status of the regulation for medical devices

    OpenAIRE

    Shah Anuja; Goyal R

    2008-01-01

    In the light of escalating use of medical devices, stringent regulatory standards are required to ensure that the devices are safe, well studied and have least adverse reactions. Recently introduced guidelines and the amendment in the law will provide adequate guidance for both the manufacturers and competent authorities to manage cases efficiently and appropriately. India has emerged as one of the leaders in pharmaceutical industry. Like many other amendments in Drugs and Cosmetics Act that ...

  12. Ophthalmic Drug Dosage Forms: Characterisation and Research Methods

    Directory of Open Access Journals (Sweden)

    Przemysław Baranowski

    2014-01-01

    Full Text Available This paper describes hitherto developed drug forms for topical ocular administration, that is, eye drops, ointments, in situ gels, inserts, multicompartment drug delivery systems, and ophthalmic drug forms with bioadhesive properties. Heretofore, many studies have demonstrated that new and more complex ophthalmic drug forms exhibit advantage over traditional ones and are able to increase the bioavailability of the active substance by, among others, reducing the susceptibility of drug forms to defense mechanisms of the human eye, extending contact time of drug with the cornea, increasing the penetration through the complex anatomical structure of the eye, and providing controlled release of drugs into the eye tissues, which allows reducing the drug application frequency. The rest of the paper describes recommended in vitro and in vivo studies to be performed for various ophthalmic drugs forms in order to assess whether the form is acceptable from the perspective of desired properties and patient’s compliance.

  13. Post market surveillance in the german medical device sector - current state and future perspectives.

    Science.gov (United States)

    Zippel, Claus; Bohnet-Joschko, Sabine

    2017-08-01

    Medical devices play a central role in the diagnosis and treatment of diseases but also bring the potential for adverse events, hazards or malfunction with serious consequences for patients and users. Medical device manufacturers are therefore required by law to monitor the performance of medical devices that have been approved by the competent authorities (post market surveillance). Conducting a nationwide online-survey in the German medical device sector in Q2/2014 in order to explore the current status of the use of post market instruments we obtained a total of 118 complete data sets, for a return rate of 36%. The survey included manufacturers of different sizes, producing medical devices of all risk classes. The post market instruments most frequently reported covered the fields of production monitoring and quality management as well as literature observation, regulatory vigilance systems, customer knowledge management and market observation while Post Market Clinical Follow-up and health services research were being used less for product monitoring. We found significant differences between the different risk classes of medical devices produced and the intensity of use of post market instruments. Differences between company size and the intensity of instruments used were hardly detected. Results may well contribute to the development of device monitoring which is a crucial element of the policy and regulatory system to identify device-related safety issues. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Image Quality Characteristics of Handheld Display Devices for Medical Imaging

    Science.gov (United States)

    Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo

    2013-01-01

    Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113

  15. "Joint Workshop on High Confidence Medical Devices, Software, and Systems (HCMDSS) and Medical Device Plug-and-Play (MD PnP) Interoperability"

    National Research Council Canada - National Science Library

    Goldman, Julian M

    2008-01-01

    Partial support was requested from TATRC, with joint funding from NSF, for a joint workshop to bring together the synergistic efforts and communities of the High Confidence Medical Devices, Software, and Systems (HCMDSS...

  16. Value driven innovation in medical device design: a process for balancing stakeholder voices.

    Science.gov (United States)

    de Ana, F J; Umstead, K A; Phillips, G J; Conner, C P

    2013-09-01

    The innovation process has often been represented as a linear process which funnels customer needs through various business and process filters. This method may be appropriate for some consumer products, but in the medical device industry there are some inherent limitations to the traditional innovation funnel approach. In the medical device industry, there are a number of stakeholders who need to have their voices heard throughout the innovation process. Each stakeholder has diverse and unique needs relating to the medical device, the needs of one may highly affect the needs of another, and the relationships between stakeholders may be tenuous. This paper describes the application of a spiral innovation process to the development of a medical device which considers three distinct stakeholder voices: the Voice of the Customer, the Voice of the Business and the Voice of the Technology. The process is presented as a case study focusing on the front-end redesign of a class III medical device for an orthopedics company. Starting from project initiation and scope alignment, the process describes four phases, Discover, Envision, Create, and Refine, and concludes with value assessment of the final design features.

  17. ISO 13485 a complete guide to quality management in the medical device industry

    CERN Document Server

    Abuhav, Itay

    2011-01-01

    Although complex and lengthy, the process of certification for the ISO 13485 can be easily mastered using the simple method outlined in ISO 13485: A Complete Guide to Quality Management in the Medical Device Industry. Written by an experienced industry professional, this practical book provides a complete guide to the ISO 13485 Standard certification for medical device manufacturing. Filled with examples drawn from the author's experience and spanning different sectors and fields of the medical device industry, the book translates the extra ordinary requirements and objectives of the standard

  18. Challenges Encountered Using Ophthalmic Anesthetics in Space Medicine

    Science.gov (United States)

    Bayuse, T.; Law, J.; Alexander, D.; Moynihan, S.; LeBlanc, C.; Langford, K.; Magalhaes, L.

    2015-01-01

    On orbit, ophthalmic anesthetics are used for tonometry and off-nominal corneal examinations. Proparacaine has been flown traditionally. However, the manufacturers recently changed its storage requirements from room temperature storage to refrigerated storage to preserve stability and prolong the shelf-life. Since refrigeration on orbit is not readily available and there were stability concerns about flying proparacaine unrefrigerated, tetracaine was selected as an alternative ophthalmic anesthetic in 2013. We will discuss the challenges encountered flying and using these anesthetics on the International Space Station.

  19. Stretchable bioelectronics for medical devices and systems

    CERN Document Server

    Ghaffari, Roozbeh; Kim, Dae-Hyeong

    2016-01-01

    This book highlights recent advances in soft and stretchable biointegrated electronics. A renowned group of authors address key ideas in the materials, processes, mechanics, and devices of soft and stretchable electronics; the wearable electronics systems; and bioinspired and implantable biomedical electronics. Among the topics discussed are liquid metals, stretchable and flexible energy sources, skin-like devices, in vitro neural recording, and more. Special focus is given to recent advances in extremely soft and stretchable bio-inspired electronics with real-world clinical studies that validate the technology. Foundational theoretical and experimental aspects are also covered in relation to the design and application of these biointegrated electronics systems. This is an ideal book for researchers, engineers, and industry professionals involved in developing healthcare devices, medical tools and related instruments relevant to various clinical practices.

  20. A model of user engagement in medical device development.

    Science.gov (United States)

    Grocott, Patricia; Weir, Heather; Ram, Mala Bridgelal

    2007-01-01

    The purpose of this paper is to address three topical themes: user involvement in health services research; determining the value of new medical technologies in patient care pathways, furthering knowledge related to quality in health and social care; and knowledge exchange between manufacturers, health service supply chain networks and device users. The model is being validated in a case study in progress. The latter is a "proving ground" study for a translational research company. Medical devices play a pivotal role in the management of chronic diseases, across all care settings. Failure to engage users in device development inevitably affects the quality of clinical outcomes. A model of user engagement is presented, turning unmet needs for medical devices into viable commercial propositions. A case study investigating the perceptions of individuals with Epidermolysis Bullosa (EB), their lay and professional carers into unmet needs. EB is an inherited condition affecting the skin and mucosal linings that leads to blistering and wounds. Qualitative data are being collected to generate understanding of unmet needs and wound care products. These needs are being translated into new design concepts and prototypes. Prototypes will be evaluated in an n = 1 experimental design, generating quantitative outcomes data. There are generalisations from the case study, and the model outlined. New products for managing EB wounds can logically benefit other groups. The model is transferable to other clinical problems, which can benefit from research and technological advances that are integral to clinical needs and care.

  1. How can cardiothoracic and vascular medical devices stay in the market?

    Science.gov (United States)

    Wong, Kathie A; Hodgson, Luke; Garas, George; Malietzis, George; Markar, Sheraz; Rao, Christopher; von Segesser, Ludwig K; Athanasiou, Thanos

    2016-12-01

    Surgeons, as the consumers, must engage in commercial activity regarding medical devices since it directly has impacts on surgical practice and patient outcomes. Unique features defy traditional economic convention in this specific market partly because consumers do not usually pay directly. Greater involvement with commercial activity means better post-market surveillance of medical devices which leads to improved patient safety. The medical device industry has exhibited astonishing levels of growth and profitability reaching $398 billion on a global scale with new product development focusing on unmet clinical need. The industry has rapidly emerged within the context of an ageing population and a global surge in healthcare spending. But the market remains fragmented. The split of consumer, purchaser and payer leads to clinical need driving demand for new product development. This demand contributes to potentially large profit margins mainly contained by regulatory burden and liability issues. Demographic trends, prevalence of diseases and a huge capacity to absorb technology have sustained near unparalleled growth. To stay in the market, incremental development over the short term is essentially aided by responsiveness to demand. Disruptive product development is now more likely to come from multinational companies, in an increasingly expensive, regulated industry. Understanding healthcare organization can help explain the highly complex process of diffusion of innovations in healthcare that include medical devices. The time has come for surgeons to become actively involved with all aspects of the medical device life cycle including commercial activity and post-market surveillance. This is vital for improving patient care and ensuring patient safety. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Effects of Medical Device Regulations on the Development of Stand-Alone Medical Software: A Pilot Study.

    Science.gov (United States)

    Blagec, Kathrin; Jungwirth, David; Haluza, Daniela; Samwald, Matthias

    2018-01-01

    Medical device regulations which aim to ensure safety standards do not only apply to hardware devices but also to standalone medical software, e.g. mobile apps. To explore the effects of these regulations on the development and distribution of medical standalone software. We invited a convenience sample of 130 domain experts to participate in an online survey about the impact of current regulations on the development and distribution of medical standalone software. 21 respondents completed the questionnaire. Participants reported slight positive effects on usability, reliability, and data security of their products, whereas the ability to modify already deployed software and customization by end users were negatively impacted. The additional time and costs needed to go through the regulatory process were perceived as the greatest obstacles in developing and distributing medical software. Further research is needed to compare positive effects on software quality with negative impacts on market access and innovation. Strategies for avoiding over-regulation while still ensuring safety standards need to be devised.

  3. Cerebral Angiographic Findings of Cosmetic Facial Filler-related Ophthalmic and Retinal Artery Occlusion

    OpenAIRE

    Kim, Yong-Kyu; Jung, Cheolkyu; Woo, Se Joon; Park, Kyu Hyung

    2015-01-01

    Cosmetic facial filler-related ophthalmic artery occlusion is rare but is a devastating complication, while the exact pathophysiology is still elusive. Cerebral angiography provides more detailed information on blood flow of ophthalmic artery as well as surrounding orbital area which cannot be covered by fundus fluorescein angiography. This study aimed to evaluate cerebral angiographic features of cosmetic facial filler-related ophthalmic artery occlusion patients. We retrospectively reviewed...

  4. 21 CFR 886.4400 - Electronic metal locator.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4400 Electronic metal locator. (a) Identification. An electronic metal locator is an AC-powered device with probes intended to locate metallic foreign bodies in the eye or eye socket. (b) Classification. Class II. ...

  5. 78 FR 66941 - Design Considerations for Pivotal Clinical Investigations for Medical Devices; Guidance for...

    Science.gov (United States)

    2013-11-07

    .... 66, rm. 2110, Silver Spring, MD 20993-0002, 301- 796-5750. For devices regulated by CBER: Stephen... the best clinical and statistical practices for investigational medical device studies. A medical...

  6. CHECKPOINT INHIBITOR IMMUNE THERAPY: Systemic Indications and Ophthalmic Side Effects.

    Science.gov (United States)

    Dalvin, Lauren A; Shields, Carol L; Orloff, Marlana; Sato, Takami; Shields, Jerry A

    2018-06-01

    To review immune checkpoint inhibitor indications and ophthalmic side effects. A literature review was performed using a PubMed search for publications between 1990 and 2017. Immune checkpoint inhibitors are designed to treat system malignancies by targeting one of three ligands, leading to T-cell activation for attack against malignant cells. These ligands (and targeted drug) include cytotoxic T-lymphocyte antigen-4 (CTLA-4, ipilimumab), programmed death protein 1 (PD-1, pembrolizumab, nivolumab), and programmed death ligand-1 (PD-L1, atezolizumab, avelumab, durvalumab). These medications upregulate the immune system and cause autoimmune-like side effects. Ophthalmic side effects most frequently manifest as uveitis (1%) and dry eye (1-24%). Other side effects include myasthenia gravis (n = 19 reports), inflammatory orbitopathy (n = 11), keratitis (n = 3), cranial nerve palsy (n = 3), optic neuropathy (n = 2), serous retinal detachment (n = 2), extraocular muscle myopathy (n = 1), atypical chorioretinal lesions (n = 1), immune retinopathy (n = 1), and neuroretinitis (n = 1). Most inflammatory side effects are managed with topical or periocular corticosteroids, but advanced cases require systemic corticosteroids and cessation of checkpoint inhibitor therapy. Checkpoint inhibitors enhance the immune system by releasing inhibition on T cells, with risk of autoimmune-like side effects. Ophthalmologists should include immune-related adverse events in their differential when examining cancer patients with new ocular symptoms.

  7. 21 CFR 886.1700 - Pupillometer.

    Science.gov (United States)

    2010-04-01

    ... eye. (b) Classification. Class I (general controls). The AC-powered device and the manual device are... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1700 Pupillometer. (a) Identification. A pupillometer is an AC...

  8. 21 CFR 886.1250 - Euthyscope.

    Science.gov (United States)

    2010-04-01

    ... disease of the eye). (b) Classification. Class I for the battery powered device. The battery powered... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1250 Euthyscope. (a) Identification. A euthyscope is a device...

  9. OR.NET RT: how service-oriented medical device architecture meets real-time communication.

    Science.gov (United States)

    Pfeiffer, Jonas H; Kasparick, Martin; Strathen, Benjamin; Dietz, Christian; Dingler, Max E; Lueth, Tim C; Timmermann, Dirk; Radermacher, Klaus; Golatowski, Frank

    2018-02-23

    Today's landscape of medical devices is dominated by stand-alone systems and proprietary interfaces lacking cross-vendor interoperability. This complicates or even impedes the innovation of novel, intelligent assistance systems relying on the collaboration of medical devices. Emerging approaches use the service-oriented architecture (SOA) paradigm based on Internet protocol (IP) to enable communication between medical devices. While this works well for scenarios with no or only soft timing constraints, the underlying best-effort communication scheme is insufficient for time critical data. Real-time (RT) networks are able to reliably guarantee fixed latency boundaries, for example, by using time division multiple access (TDMA) communication patterns. However, deterministic RT networks come with their own limitations such as tedious, inflexible configuration and a more restricted bandwidth allocation. In this contribution we overcome the drawbacks of both approaches by describing and implementing mechanisms that allow the two networks to interact. We introduce the first implementation of a medical device network that offers hard RT guarantees for control and sensor data and integrates into SOA networks. Based on two application examples we show how the flexibility of SOA networks and the reliability of RT networks can be combined to achieve an open network infrastructure for medical devices in the operating room (OR).

  10. Scouting For Approval: Lessons on Medical Device Regulation in an Era of Crowdfunding from Scanadu's "Scout".

    Science.gov (United States)

    Smith, Colleen

    2015-01-01

    Internet crowdfunding, a new and increasingly popular method of raising capital to develop products and businesses, has recently come into conflict with the Food and Drug Administration's (FDA's) regulation of medical devices. This Article examines the issues that arise when companies pre-sell medical devices via crowdfunding campaigns before gaining FDA approval of the devices. Because Internet crowdfunding has only been in use for a few years, little has been written about it academically, particularly about its interaction with FDA regulations. The rising interest in crowdfunding, coupled with the downturn in investment in the American medical device industry, make this a salient issue that is ripe for FDA review. This Article uses the crowdfunding campaign Scanadu, a medical device company, conducted in 2013 to raise money to develop its in-home diagnostic device, the "Scout," as a starting point for this analysis. Because it is extremely costly to develop a device and obtain FDA approval, medical device companies should be able to utilize crowdfunding to raise the necessary capital. However, because of the possible dangers medical devices pose, FDA needs to review the risks created by allowing companies to crowdfund medical devices and should issue guidance to help companies comply with FDA regulations while still allowing them to take advantage of the benefits of crowdfunding. This guidance should ensure the continued commitment to consumer safety that is at the core of FDA regulation.

  11. Risk factors of ophthalmic disorders in children with developmental delay

    DEFF Research Database (Denmark)

    Sandfeld, L.N.; Jensen, H.; Skov, L.

    2008-01-01

    PURPOSE: To identify diagnoses that increase the risk of ophthalmic disorders in developmentally delayed children. METHODS: A cross-sectional study of 1126 Danish children with developmental delay (IQ Udgivelsesdato: 2008/12......PURPOSE: To identify diagnoses that increase the risk of ophthalmic disorders in developmentally delayed children. METHODS: A cross-sectional study of 1126 Danish children with developmental delay (IQ Udgivelsesdato: 2008/12...

  12. 21 CFR 524.1662 - Oxytetracycline hydrochloride ophthalmic and topical dosage forms.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Oxytetracycline hydrochloride ophthalmic and topical dosage forms. 524.1662 Section 524.1662 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... DOSAGE FORM NEW ANIMAL DRUGS § 524.1662 Oxytetracycline hydrochloride ophthalmic and topical dosage forms. ...

  13. Determination of permeability coefficients of ophthalmic drugs through different layers of porcine, rabbit and bovine eyes

    OpenAIRE

    Nagel, Stefan; Guthoff, Rudolf F.; Weitschies, Werner; Seidlitz, Anne; Kristl, Albin; Žakelj, Simon; Loch, Christian

    2015-01-01

    To treat ophthalmic diseases like glaucoma or inflammatory disorders topically applied ophthalmic formulations such as eye drops are usually used. In addition, novel ophthalmic implants releasing drug substances locally into different parts of the eye are available today. In the work presented here, the permeability coefficients of selected drugs (ciprofloxacin hydrochloride, lidocaine hydrochloride, timolol maleate) for ophthalmic tissues were determined using side-by-side diffusion chambers...

  14. Comfort level of post graduate residents working in different clinical domains in managing common ophthalmic conditions

    International Nuclear Information System (INIS)

    Jaffar, S.; Tayyab, A.; Shah, S.S.; Naseem, S.; Ghazanfar, H.

    2016-01-01

    Background: Ophthalmological conditions are frequently encountered in almost all clinical specialties. Assessing the adequacy of ophthalmology teaching in undergraduate medical education is important in order to diagnose and manage different ophthalmological conditions. The objective of this study was to determine the comfort level of post graduate residents working in different clinical domains in managing common ophthalmic conditions. Methods: A cross sectional survey involving 277 post graduate residents was carried out over a period of six months in both private and public tertiary care hospital. A questionnaire containing two sections and 17 variables in total were distributed among Medical Residents of different specialties except ophthalmology residents. Participants of the study were selected through consecutive non probability sampling. Results: Mean hours of classroom based ophthalmology instruction during during undergraduate program was 59.38 hours (55.9) and mean hours of clinical based ophthalmology instruction during undergraduate program was 62.73 hours (60.8) 54 percentage were either not comfortable or somewhat comfortable in managing common ophthalmic condition. Conclusion: Teaching hours in under graduate program meet or exceed requisite criteria. However graduating doctors generally feel that the time spent does not provide them with the comfort and skill level required to care for patients with ocular presentations. (author)

  15. Comparison of Drug Concentrations in Human Aqueous Humor after the Administration of 0.3% Gatifloxacin Ophthalmic Gel, 0.3% Gatifloxacin and 0.5% Levofloxacin Ophthalmic Solutions.

    Science.gov (United States)

    Ding, Wenting; Ni, Weiling; Chen, Huilian; Yuan, Jingqun; Huang, Xiaodan; Zhang, Zheng; Wang, Yao; Yu, Yibo; Yao, Ke

    2015-01-01

    To investigate the penetration of 0.3% gatifloxacin ophthalmic gel, 0.3% gatifloxacin ophthalmic solution and 0.5% levofloxacin ophthalmic solution into aqueous humor after topical application. Age-related cataract patients (150 eyes in 150 cases) receiving phacoemulsification were randomly divided into three groups: a 0.3% gatifloxacin gel group (n=50), a 0.3% gatifloxacin solution group (n=50), and a 0.5% levofloxacin solution group (n=50). Each group was administered one drop of gel or solution every 15 minutes for four doses. Aqueous samples were collected at different time points after the last drop. High pressure liquid chromatography (HPLC) was applied to determine the concentrations. The one-way ANOVA analysis was performed. Our data indicated that the concentration of the gatifloxacin gel group was higher than that of the gatifloxacin solution group at all time points (P solution group at 120.0 min and 180.0 min (Psolutions reached their peak values at 60.0 min. 0.3% gatifloxacin ophthalmic gel application produced highest aqueous humor drug concentration, maintained the longest time, had the best penetration and bioavailability.

  16. Monitoring of Vital Signs with Flexible and Wearable Medical Devices.

    Science.gov (United States)

    Khan, Yasser; Ostfeld, Aminy E; Lochner, Claire M; Pierre, Adrien; Arias, Ana C

    2016-06-01

    Advances in wireless technologies, low-power electronics, the internet of things, and in the domain of connected health are driving innovations in wearable medical devices at a tremendous pace. Wearable sensor systems composed of flexible and stretchable materials have the potential to better interface to the human skin, whereas silicon-based electronics are extremely efficient in sensor data processing and transmission. Therefore, flexible and stretchable sensors combined with low-power silicon-based electronics are a viable and efficient approach for medical monitoring. Flexible medical devices designed for monitoring human vital signs, such as body temperature, heart rate, respiration rate, blood pressure, pulse oxygenation, and blood glucose have applications in both fitness monitoring and medical diagnostics. As a review of the latest development in flexible and wearable human vitals sensors, the essential components required for vitals sensors are outlined and discussed here, including the reported sensor systems, sensing mechanisms, sensor fabrication, power, and data processing requirements. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. 78 FR 27971 - Determination That REV-EYES (Dapiprazole Hydrochloride Ophthalmic Solution), 0.5%, Was Not...

    Science.gov (United States)

    2013-05-13

    ...] Determination That REV-EYES (Dapiprazole Hydrochloride Ophthalmic Solution), 0.5%, Was Not Withdrawn From Sale... ophthalmic solution), 0.5%, was not withdrawn from sale for reasons of safety or effectiveness. This... ophthalmic solution, 0.5%, if all other legal and regulatory requirements are met. FOR FURTHER INFORMATION...

  18. Medical devices and the Middle East: market, regulation, and reimbursement in Gulf Cooperation Council states

    Directory of Open Access Journals (Sweden)

    Howard JJ

    2014-11-01

    Full Text Available Jason J Howard Division of Paediatric Orthopaedics, Department of Surgery, Sidra Medical and Research Center, Doha, Qatar Abstract: With some of the richest economies in the world, the Gulf Cooperation Council (GCC is undergoing rapid growth not only in its population but also in health care expenditure. Despite the GCC's abundance of hydrocarbon-based wealth, the drivers of the medical device industry in the GCC are still in flux, with gains yet to be made in areas of infrastructure, regulation, and reimbursement. However, the regional disease burden, expanding health insurance penetration, increasing privatization, and a desire to attract skilled expatriate health care providers have led to favorable conditions for the medical device market in the GCC. The purpose of this article is to investigate the current state of the GCC medical device industry, with respect to market, regulation, and reimbursement, paying special attention to the three largest medical device markets: Saudi Arabia, the United Arab Emirates, and Qatar. The GCC would seem to represent fertile ground for the development of medical technologies, especially those in line with the regional health priorities of the respective member states. Keywords: medical devices, regulation, reimbursement, Middle East 

  19. Mobile devices in medicine: a survey of how medical students, residents, and faculty use smartphones and other mobile devices to find information*

    Science.gov (United States)

    Boruff, Jill T.; Storie, Dale

    2014-01-01

    Objectives: The research investigated the extent to which students, residents, and faculty members in Canadian medical faculties use mobile devices, such as smartphones (e.g., iPhone, Android, Blackberry) and tablet computers (e.g., iPad), to answer clinical questions and find medical information. The results of this study will inform how health libraries can effectively support mobile technology and collections. Methods: An electronic survey was distributed by medical librarians at four Canadian universities to medical students, residents, and faculty members via departmental email discussion lists, personal contacts, and relevant websites. It investigated the types of information sought, facilitators to mobile device use in medical information seeking, barriers to access, support needs, familiarity with institutionally licensed resources, and most frequently used resources. Results: The survey of 1,210 respondents indicated widespread use of smartphones and tablets in clinical settings in 4 Canadian universities. Third- and fourth-year undergraduate students (i.e., those in their clinical clerkships) and medical residents, compared to other graduate students and faculty, used their mobile devices more often, used them for a broader range of activities, and purchased more resources for their devices. Conclusions: Technological and intellectual barriers do not seem to prevent medical trainees and faculty from regularly using mobile devices for their medical information searches; however, barriers to access and lack of awareness might keep them from using reliable, library-licensed resources. Implications: Libraries should focus on providing access to a smaller number of highly used mobile resources instead of a huge collection until library-licensed mobile resources have streamlined authentication processes. PMID:24415916

  20. Mobile devices in medicine: a survey of how medical students, residents, and faculty use smartphones and other mobile devices to find information.

    Science.gov (United States)

    Boruff, Jill T; Storie, Dale

    2014-01-01

    The research investigated the extent to which students, residents, and faculty members in Canadian medical faculties use mobile devices, such as smartphones (e.g., iPhone, Android, Blackberry) and tablet computers (e.g., iPad), to answer clinical questions and find medical information. The results of this study will inform how health libraries can effectively support mobile technology and collections. An electronic survey was distributed by medical librarians at four Canadian universities to medical students, residents, and faculty members via departmental email discussion lists, personal contacts, and relevant websites. It investigated the types of information sought, facilitators to mobile device use in medical information seeking, barriers to access, support needs, familiarity with institutionally licensed resources, and most frequently used resources. The survey of 1,210 respondents indicated widespread use of smartphones and tablets in clinical settings in 4 Canadian universities. Third- and fourth-year undergraduate students (i.e., those in their clinical clerkships) and medical residents, compared to other graduate students and faculty, used their mobile devices more often, used them for a broader range of activities, and purchased more resources for their devices. Technological and intellectual barriers do not seem to prevent medical trainees and faculty from regularly using mobile devices for their medical information searches; however, barriers to access and lack of awareness might keep them from using reliable, library-licensed resources. Libraries should focus on providing access to a smaller number of highly used mobile resources instead of a huge collection until library-licensed mobile resources have streamlined authentication processes.

  1. Implantable Medical Devices; Networking Security Survey

    OpenAIRE

    Siamak Aram; Rouzbeh A. Shirvani; Eros G. Pasero; Mohamd F. Chouikha

    2016-01-01

    The industry of implantable medical devices (IMDs) is constantly evolving, which is dictated by the pressing need to comprehensively address new challenges in the healthcare field. Accordingly, IMDs are becoming more and more sophisticated. Not long ago, the range of IMDs’ technical capacities was expanded, making it possible to establish Internet connection in case of necessity and/or emergency situation for the patient. At the same time, while the web connectivity of today’s implantable dev...

  2. Framework conditions and requirements to ensure the technical functional safety of reprocessed medical devices.

    Science.gov (United States)

    Kraft, Marc

    2008-09-03

    Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device. Functional tests are, however, also a part of reprocessing procedures. As a stage in the reprocessing, they ensure for the individual medical device that no damage or other changes limit the performance. When determining which technical-functional tests are to be carried out, the current technological standard has to be taken into account in the form of product-specific and process-oriented norms. Product-specific norms primarily define safety-relevant requirements. The risk management method described in DIN EN ISO 14971 is the basis for recognising hazards; the likelihood of such hazards arising can be minimised through additional technical-functional tests, which may not yet have been standardised. Risk management is part of a quality management system, which must be bindingly certified for manufacturers and processors of critical medical devices with particularly high processing demands by a body accredited by the competent authority.

  3. 77 FR 3781 - Pediatric Medical Devices; Public Workshop; Reopening of Comment Period

    Science.gov (United States)

    2012-01-25

    ... devices. DATES: Submit either electronic or written comments by March 5, 2012. ADDRESSES: Submit.... Designing pediatric medical devices can be challenging; children are often smaller and more active than adults; body structures and functions change throughout childhood, and children may be long-term device...

  4. 21 CFR 886.1870 - Stereoscope.

    Science.gov (United States)

    2010-04-01

    ... exercises of eye muscles. (b) Classification. Class I (general controls). The AC-powered device and the... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1870 Stereoscope. (a) Identification. A stereoscope is an AC...

  5. A Maturity Grid Assessment Tool for Environmentally Conscious Design in the Medical Device Industry

    DEFF Research Database (Denmark)

    Moultrie, James; Sutcliffe, Laura Francesca Rose; Maier, Anja

    2016-01-01

    . This intervention tool provides designers and product marketers with insights on how to improve the design of their medical devices and specifically allows consideration of the complex trade-offs between decisions that influence different life-cycle stages. Through the tool, actionable insight is created......The medical device industry is growing increasingly concerned about environmental impact of products. Whilst there are many tools aiming to support environmentally conscious design, they are typically complex to use, demand substantial data collection and are not tailored to the specific needs...... of the medical device sector. This paper reports on the development of a Maturity Grid to address this gap. This novel design tool was developed iteratively through application in five case studies. The tool captures principles of eco-design for medical devices in a simple form, designed to be used by a team...

  6. Initiatives in the Australian Medical Devices Industry

    International Nuclear Information System (INIS)

    Whelan, Luke

    2005-01-01

    The medical device industry is as diverse as it is specialised and calls on the innovative use of design and components and utilises all facets of precision manufacturing from printed circuit boards, injection-moulded plastics to engineering, using a wide range of materials. It generally requires exacting standards, starting with design, particularly for devices that are invasive or have direct contact with the human body. Of course this brings the further consideration of sterilisation and whether it is for single or multiple use. There is an ever-present need to produce more accurate less invasive and cheaper devices. The driving motivation appears to be meeting clinical needs at a reduced cost. The push to treat people outside the hospital is growing, creating new demands and directions. The advent of the Internet and wireless technology has opened a whole new direction of research and development opportunities

  7. 78 FR 27971 - Dental Products Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2013-05-13

    ...] Dental Products Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and Drug...: Dental Products Panel of the Medical Devices Advisory Committee. General Function of the Committee: To... regulatory classification for dental devices known as Endosseous Dental Implants (Blade-form), one of the...

  8. 78 FR 5327 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug

    Science.gov (United States)

    2013-01-25

    ...). Executive Orders 12866 and 13563 direct Agencies to assess all costs and benefits of available regulatory... (including potential economic, environmental, public health and safety, and other advantages; distributive... with or without gold, silver, or titanium coating, manufacturers could begin marketing after they...

  9. 78 FR 9349 - Medical Devices; Ophthalmic Devices; Classification of the Eyelid Weight

    Science.gov (United States)

    2013-02-08

    ... value of the savings ranges from $28,746, at a 3-percent discount rate, to $20,470 at a 7-percent discount rate. C. Preliminary Regulatory Impact Analysis 1. Benefits Adopting the proposed rule would... value of the savings is $28,746, at a 3-percent discount rate, and $20,470, at a 7-percent discount rate...

  10. 21 CFR 886.4100 - Radiofrequency electrosurgical cautery apparatus.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiofrequency electrosurgical cautery apparatus... SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4100 Radiofrequency electrosurgical cautery apparatus. (a) Identification. A radiofrequency electrosurgical cautery apparatus is an AC...

  11. In vitro testing of thiolated poly(aspartic acid) from ophthalmic formulation aspects.

    Science.gov (United States)

    Budai-Szű Cs, Mária; Horvát, Gabriella; Gyarmati, Benjámin; Szilágyi, Barnabás Áron; Szilágyi, András; Csihi, Tímea; Berkó, Szilvia; Szabó-Révész, Piroska; Mori, Michela; Sandri, Giuseppina; Bonferoni, Maria Cristina; Caramella, Carla; Csányi, Erzsébet

    2016-08-01

    Ocular drug delivery formulations must meet anatomical, biopharmaceutical, patient-driven and regulatory requirements. Mucoadhesive polymers can serve as a better alternative to currently available ophthalmic formulations by providing improved bioavailability. If all requirements are addressed, a polymeric formulation resembling the tear film of the eye might be the best solution. The optimum formulation must not have high osmotic activity, should provide appropriate surface tension, pH and refractive index, must be non-toxic and should be transparent and mucoadhesive. We would like to highlight the importance of in vitro polymer testing from a pharmaceutical aspect. We, therefore, carried out physical-chemical investigations to verify the suitability of certain systems for ophthalmic formulations. In this work, in situ gelling, mucoadhesive thiolated poly(aspartic acid)s were tested from ophthalmic formulation aspects. The results of preformulation measurements indicate that these polymers can be used as potential carriers in ophthalmic drug delivery.

  12. Impact of digital imaging and communications in medicine workflow on the integration of patient demographics and ophthalmic test data.

    Science.gov (United States)

    Pandit, Ravi R; Boland, Michael V

    2015-02-01

    To determine the impact of a Digital Imaging and Communications in Medicine (DICOM) workflow on the linkage of demographic information to ophthalmic testing data. Evaluation of technology. Six hundred ninety-nine visual field testing encounters performed by 6 ophthalmic technicians and the transfer error queue of 37 442 ophthalmic test results. At 3 months before and 6 and 18 months after implementation of a DICOM workflow, technicians recorded the work required to enter, confirm, or edit patient demographics in each visual field device. We also determined the proportion of imaging tests sent to an error queue for manual reconciliation because of incorrect demographic information before and 3, 6, and 18 months after the DICOM workflow was established. The proportion of testing encounters for which staff had to enter, edit, or merge patient demographics and the proportion of misfiled images. Staff entered, edited, or merged data for 48% of patients before implementation (n = 237). This decreased to 24% within 6 months and 20% within 18 months of implementing the DICOM archive (n = 230 and n = 232, respectively). Staff could locate a patient in a DICOM work list for 97% of encounters at 3 months and 99% at 18 months. Before implementation, 9.2% of the images required additional intervention to be associated with the correct patient (n = 3581). This decreased by 85% over 6 months to 1.4% (n = 9979; P workflow in an ophthalmology clinic reduced the need to enter or edit patient demographic information into imaging or testing devices by more than 50% and reduced the need to manage misfiled images by 76%. In a clinical environment that demands both efficiency and patient safety, the DICOM workflow is an important update to current practice. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  13. Medical Procedures and Risk for Sporadic Creutzfeldt-Jakob Disease, Japan, 1999–2008

    Science.gov (United States)

    Hamaguchi, Tsuyoshi; Noguchi-Shinohara, Moeko; Nozaki, Ichiro; Nakamura, Yosikazu; Sato, Takeshi; Kitamoto, Tetsuyuki; Mizusawa, Hidehiro

    2009-01-01

    To elucidate the association between medical procedures and sporadic Creutzfeldt-Jakob disease (sCJD), we analyzed medical procedures (any surgical procedure, neurosurgery, ophthalmic surgery, and blood transfusion) for patients registered by the CJD Surveillance Committee in Japan during 1999–2008. We conducted an age-stratified case–control study with 753 sCJD patients and 210 controls and a study of patients who underwent neurosurgical or ophthalmic surgical procedures at the same hospital. Although the control group was relatively small, no evidence was found that prion disease was transmitted through the investigated medical procedures before onset of sCJD. After onset of sCJD, 4.5% of the sCJD patients underwent operations, including neurosurgical for 0.8% and ophthalmic for 1.9%; no special precautions against transmission of prion diseases were taken. Fortunately, we have not identified patients with prion disease attributed to these operations. Our findings indicate that surgical procedures or blood transfusion had little effect on the incidence of sCJD. PMID:19193271

  14. Comparison of the effectiveness of contemporary ophthalmic lenses against β radiation

    International Nuclear Information System (INIS)

    Dunlap, J.H.; Harvey, P.W.; Schwing, R.L.

    1977-01-01

    As part of a study intended to identify the lens material and type that provides maximum eye protection against beta radiation, the effectiveness of contemporary ophthalmic lenses has been evaluated. From the calculations and measurements presented it is evident that safety glasses with crown glass ophthalmic lenses afford the eye the greatest protection against beta radiation, whereas street glasses with plastic ophthalmic lenses afford the eye very little protection. It is to be noted that glass street lenses (approximately 2.2 mm thick) provide greater protection than plastic safety lenses (approximately 3.5 mm thick). A warning is given against the use of safety lenses containing a large percentage of thorium. (U.K.)

  15. Biomaterials and medical devices a perspective from an emerging country

    CERN Document Server

    Hermawan, Hendra

    2016-01-01

    This book presents an introduction to biomaterials with the focus on the current development and future direction of biomaterials and medical devices research and development in Indonesia. It is the first biomaterials book written by selected academic and clinical experts experts on biomaterials and medical devices from various institutions and industries in Indonesia. It serves as a reference source for researchers starting new projects, for companies developing and marketing products and for governments setting new policies. Chapter one covers the fundamentals of biomaterials, types of biomaterials, their structures and properties and the relationship between them. Chapter two discusses unconventional processing of biomaterials including nano-hybrid organic-inorganic biomaterials. Chapter three addresses biocompatibility issues including in vitro cytotoxicity, genotoxicity, in vitro cell models, biocompatibility data and its related failure. Chapter four describes degradable biomaterial for medical implants...

  16. Additive Manufacturing for Robust and Affordable Medical Devices

    OpenAIRE

    Wolozny Gomez Robelo, Daniel Andre

    2016-01-01

    Additive manufacturing in the form of 3D printing is a revolutionary technology that has developed within the last two decades. Its ability to print an object with accurate features down to the micro scale have made its use in medical devices and research feasible. A range of life-saving technologies can now go from the laboratory and into field with the application of 3D-printing. This technology can be applied to medical diagnosis of patients in at-risk populations. Living biosensors a...

  17. An extended protocol for usability validation of medical devices : Research design and reference model

    NARCIS (Netherlands)

    Schmettow, M.; Schnittker, R.; Schraagen, J.M.

    2017-01-01

    This paper proposes and demonstrates an extended protocol for usability validation testing of medical devices. A review of currently used methods for the usability evaluation of medical devices revealed two main shortcomings. Firstly, the lack of methods to closely trace the interaction sequences

  18. Integrated analysis of three bacterial conjunctivitis trials of besifloxacin ophthalmic suspension, 0.6%: microbiological eradication outcomes

    Directory of Open Access Journals (Sweden)

    Morris TW

    2011-09-01

    Full Text Available Timothy W Morris1, Lynne S Gearinger1, Dale W Usner2, Michael R Paterno2, Heleen H DeCory3, Timothy L Comstock3, Wolfgang Haas11Microbiology and Sterilization Sciences, 2Clinical Affairs, 3Global Pharmaceutical Medical Affairs, Bausch & Lomb, Rochester, NY, USAPurpose: To assess clinical antimicrobial efficacy results obtained with besifloxacin ophthalmic suspension, 0.6%, administered three times a day (TID for 5 days, integrated across three clinical trials of bacterial conjunctivitis and to investigate any microbiological eradication failures.Methods: Clinical microbiological eradication data from three randomized, double-masked, parallel group studies of patients with bacterial conjunctivitis (two vehicle controlled; one active controlled with moxifloxacin ophthalmic solution, 0.5% were integrated. All bacterial samples isolated at baseline above the species-specific threshold value were subjected to antimicrobial susceptibility testing. Samples isolated at subsequent visits were subjected to susceptibility testing and pulsed-field gel electrophoresis (PFGE to investigate the cause of eradication failures and the potential for drug resistance development.Results: Visit 2 (day 4 or 5 and visit 3 (day 8 overall microbiological eradication rates were 92.2% and 88.4% for besifloxacin ophthalmic suspension compared with 61.4% and 72.5% for vehicle and 91.6% and 85.7% for moxifloxacin ophthalmic solution. Visit 2 and visit 3 microbiological eradication rates for Gram-positive and Gram-negative isolates and for individual species were consistent with the overall eradication rates. The majority of observed eradication failures in any treatment group were due to the persistence of the pathogen isolated at baseline. Eradication failures in the besifloxacin treatment group were not associated with lower antimicrobial susceptibility at baseline. PFGE data showed that the majority of bacterial strains in eyes with eradication failures were identical to

  19. 76 FR 71044 - Determination That TRAVATAN (Travoprost Ophthalmic Solution), 0.004%, Was Not Withdrawn From Sale...

    Science.gov (United States)

    2011-11-16

    ...] Determination That TRAVATAN (Travoprost Ophthalmic Solution), 0.004%, Was Not Withdrawn From Sale for Reasons of... Drug Administration (FDA) has determined that TRAVATAN (travoprost ophthalmic solution), 0.004%, was... approve abbreviated new drug applications (ANDAs) for travoprost ophthalmic solution, 0.004%, if all other...

  20. 21 CFR 886.1380 - Diagnostic condensing lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic condensing lens. 886.1380 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1380 Diagnostic condensing lens. (a) Identification. A diagnostic condensing lens is a device used in binocular indirect ophthalmoscopy (a procedure...

  1. 21 CFR 886.1350 - Keratoscope.

    Science.gov (United States)

    2010-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1350 Keratoscope. (a) Identification. A keratoscope is an AC-powered or battery-powered device intended to measure and evaluate the corneal curvature of the eye. Lines...

  2. Ophthalmic variables in rehabilitated juvenile Kemp's ridley sea turtles (Lepidochelys kempii).

    Science.gov (United States)

    Gornik, Kara R; Pirie, Christopher G; Marrion, Ruth M; Wocial, Julika N; Innis, Charles J

    2016-03-15

    To determine central corneal thickness (total corneal thickness [TCT], epithelial thickness [ET], and stromal thickness [ST]), anterior chamber depth (ACD), and intraocular pressure (IOP) in Kemp's ridley sea turtles (Lepidochelys kempii). Prospective cross-sectional study. 25 healthy rehabilitated juvenile Kemp's ridley sea turtles. PROCEDURES; Body weight and straight-line standard carapace length (SCL) were recorded. All turtles underwent a complete anterior segment ophthalmic examination. Central TCT, ET, ST, and ACD were determined by use of a spectral-domain optical coherence tomography device. Intraocular pressure was determined with a rebound tonometer; the horse setting was used to measure IOP in all 25 turtles, and the undefined setting was also used to measure IOP in 20 turtles. For each variable, 3 measurements were obtained bilaterally. The mean was calculated for each eye and used for analysis purposes. The mean ± SD body weight and SCL were 3.85 ± 1.05 kg (8.47 ± 2.31 lb) and 29 ± 3 cm, respectively. The mean ± SD TCT, ET, ST, and ACD were 288 ± 23 μm, 100 ± 6 μm, 190 ± 19 μm, and 581 ± 128 μm, respectively. Mean ± SD IOP was 6.5 ± 1.0 mm Hg when measured with the horse setting and 3.8 ± 1.1 mm Hg when measured with the undefined setting. Results provided preliminary reference ranges for objective assessment of ophthalmic variables in healthy juvenile Kemp's ridley sea turtles.

  3. Distribution of microorganisms in medical devices and their inactivation effects by gamma-irradiation

    International Nuclear Information System (INIS)

    Ito, Hitoshi; Ishigaki, Isao

    1986-01-01

    Radiation treatment is getting important position for sterilizing medical devices and for packaging films of foods. Recently, survey of bioburden is an important technique for evaluation of sterility doses for medical devices. However, many studies have been done mainly on the irradiation effects of spore-forming bacteria in medical devices. In this study, radiation sensitivity of spore-forming bacteria and fungi were examined after the survey on distribution of microorganisms in several kinds of medical devices. The main contaminant in disposable syringes, needles and conical flasks were consisted of Bacillus, with lesser amount of Micrococcus, Pseudomonas, Peptococcaceae and fungi as positive of 5 - 60 % in the medical devices which cultivated in thioglycolate broth. Bacillus group were identified as B. pumilus, B. sphaericus, B. coagulans, B. megaterium and etc. Fungi were isolated a lesser amounts compared with spore-forming bacteria and identified as Blastomyces, Penicillium, Haplosporangium, Euricoa and Audeobasidium. Peptococaceae were not isolated after irradiation with a dose of 0.1 Mrad even the samples were contaminated with high percentage. The D 10 values of dryed endospores of Bacillus-isolates which attached to the filter paper with pepton-glycerin were obtained to be 0.11 - 0.19 Mrad. The D 10 values of many isolates of fungi in dry condition were obtained below 0.08 Mrad. However, the isolate of Aureobasidium is radiation-resistant, and it's D 10 values was obtained as 0.28 Mrad under aerobic and anaerobic dry condition. (author)

  4. Dendritiform Keratopathy Associated with Exposure to Polyquarternium-1, a Common Ophthalmic Preservative.

    Science.gov (United States)

    Matoba, Alice Y; Peterson, Jeff R; Wilhelmus, Kirk R

    2016-03-01

    To describe dendritiform keratopathy associated with exposure to polyquaternium-1, a common preservative found in contact lens solutions and tear replacement products. Case series. Sixteen patients who demonstrated dendritiform keratopathy during topical ophthalmic exposure to polyquaternium-1. Records were reviewed of all patients diagnosed with dendritiform keratopathy between 1999 and 2014 who had documented exposure to contact lens care disinfecting solutions or artificial tear solutions containing polyquaternium-1. Patients were excluded who had coexisting potential causes for dendritiform keratopathy, such as prior herpes simplex keratitis, varicella-zoster viral keratitis, the linear form of Thygeson's superficial keratitis, epithelial regeneration line, Acanthamoeba keratitis, mucus plaque keratopathy, medication-related keratopathy, or limbal stem cell deficiency characterized by conjunctivalization of the corneal epithelium. Effect of discontinuation of exposure to polyquaternium-1 on the dendritiform keratopathy. Sixteen patients demonstrated dendritiform keratopathy after exposure to the preservative polyquaternium-1. Thirteen patients had a history of recent exposure to contact lens disinfecting solutions (Opti-Free, Equate) containing polyquaternium-1. Three patients used a tear replacement product (Systane) containing a polyquaternium-1 preservative. Four patients were treated with antiviral medications for presumed herpes simplex keratitis; 4 patients underwent diagnostic testing for Acanthamoeba keratitis. Two additional patients were diagnosed sequentially with herpes simplex keratitis, then Acanthamoeba keratitis before referral. All dendritiform lesions resolved within 2 to 6 weeks after elimination of exposure to polyquaternium-1. Ophthalmic products containing polyquaternium-1 may cause dendritiform keratopathy that may be confused with infections of the superficial cornea, such as herpes simplex virus keratitis or Acanthamoeba keratitis

  5. Medical devices of the head, neck, and spine.

    Science.gov (United States)

    Hunter, Tim B; Yoshino, Mark T; Dzioba, Robert B; Light, Rick A; Berger, William G

    2004-01-01

    There are many medical devices used for head, neck, and spinal diseases and injuries, and new devices are constantly being introduced. Many of the newest devices are variations on a previous theme. Knowing the specific name of a device is not important. It is important to recognize the presence of a device and to have an understanding of its function as well as to be able to recognize the complications associated with its use. The article discusses the most common and important devices of the head, neck, and spine, including cerebrospinal fluid shunts and the Codman Hakim programmable valve; subdural drainage catheters, subdural electrodes, intracranial electrodes, deep brain stimulators, and cerebellar electrodes; coils, balloons, adhesives, particles, and aneurysm clips; radiation therapy catheters, intracranial balloons for drug installation, and carmustine wafers; hearing aids, cochlear implants, and ossicular reconstruction prostheses; orbital prostheses, intraocular silicone oil, and lacrimal duct stents; anterior and posterior cervical plates, posterior cervical spine wiring, odontoid fracture fixation devices, cervical collars and halo vests; thoracic and lumbar spine implants, anterior and posterior instrumentation for the thoracic and lumbar spine, vertebroplasty, and artificial disks; spinal column stimulators, bone stimulators, intrathecal drug delivery pumps, and sacral stimulators; dental and facial implant devices; gastric and tracheal tubes; vagus nerve stimulators; lumboperitoneal shunts; and temperature- and oxygen-sensing probes. Copyright RSNA, 2004

  6. A History of the Sonocare CST-100: The First FDA-approved HIFU Device

    Science.gov (United States)

    Muratore, Robert

    2006-05-01

    The Sonocare CST-100 Therapeutic Ultrasound System, designed for the treatment of glaucoma, was developed in the 1980s and became the first high intensity focused ultrasound (HIFU) device to receive Food and Drug Administration approval. The system arose from studies done by F.L. Lizzi, Eng.Sc.D., of Riverside Research Institute and D.J. Coleman, M.D., of Cornell Medical Center/New York Hospital on the safety of ultrasound diagnosis of the eye. As safety limits were probed, therapeutic regimes were discovered. Optimization of operational parameters, clinical experience, and engineering design came together through a spin-off company, Sonocare, Inc., formed to produce and market the ophthalmic device. Various precedents were set during the approval process, including the acceptance by the FDA of radiation momentum imparted to an absorber as a measure of acoustic power. Many devices were sold, but the laser industry, grandfathered into the therapeutic field, eventually out-marketed Sonocare. The CST-100 remains as a model of elegant industrial design, and existing units are used daily in HIFU laboratory experiments.

  7. Metrological Reliability of Medical Devices

    Science.gov (United States)

    Costa Monteiro, E.; Leon, L. F.

    2015-02-01

    The prominent development of health technologies of the 20th century triggered demands for metrological reliability of physiological measurements comprising physical, chemical and biological quantities, essential to ensure accurate and comparable results of clinical measurements. In the present work, aspects concerning metrological reliability in premarket and postmarket assessments of medical devices are discussed, pointing out challenges to be overcome. In addition, considering the social relevance of the biomeasurements results, Biometrological Principles to be pursued by research and innovation aimed at biomedical applications are proposed, along with the analysis of their contributions to guarantee the innovative health technologies compliance with the main ethical pillars of Bioethics.

  8. Subhyaloid Hemorrhage in a Case of Devic's Disease | Chakraborti ...

    African Journals Online (AJOL)

    We diagnosed the case as neuromyelitis optica (NMO) based on the examination and investigation findings. NMO or Devic's syndrome is an uncommon clinical syndrome associating unilateral or bilateral optic neuritis and transverse myelitis. Subhyaloid hemorrhage, as an ophthalmic feature of NMO, has not been reported ...

  9. 21 CFR 886.4300 - Intraocular lens guide.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4300 Intraocular lens guide. (a) Identification. An intraocular lens guide is a device intended to be inserted into the eye during surgery to direct... lenses, the device is exempt from the premarket notification procedures in subpart E of part 807 of this...

  10. Early-stage valuation of medical devices: the role of developmental uncertainty.

    Science.gov (United States)

    Girling, Alan; Young, Terry; Brown, Celia; Lilford, Richard

    2010-08-01

    At the concept stage, many uncertainties surround the commercial viability of a new medical device. These include the ultimate functionality of the device, the cost of producing it and whether, and at what price, it can be sold to a health-care provider (HCP). Simple assessments of value can be made by estimating such unknowns, but the levels of uncertainty may mean that their operational value for investment decisions is unclear. However, many decisions taken at the concept stage are reversible and will be reconsidered later before the product is brought to market. This flexibility can be exploited to enhance early-stage valuations. To develop a framework for valuing a new medical device at the concept stage that balances benefit to the HCP against commercial costs. This is done within a simplified stage-gated model of the development cycle for new products. The approach is intended to complement existing proposals for the evaluation of the commercial headroom available to new medical products. A model based on two decision gates can lead to lower bounds (underestimates) for product value that can serve to support a decision to develop the product. Quantifiable uncertainty that can be resolved before the device is brought to market will generally enhance early-stage valuations of the device, and this remains true even when some components of uncertainty cannot be fully described. Clinical trials and other evidence-gathering activities undertaken as part of the development process can contribute to early-stage estimates of value.

  11. Development and Evaluation of Diclofenac Sodium Loaded-N-Trimethyl Chitosan Nanoparticles for Ophthalmic Use.

    Science.gov (United States)

    Asasutjarit, Rathapon; Theerachayanan, Thitaree; Kewsuwan, Prartana; Veeranodha, Sukitaya; Fuongfuchat, Asira; Ritthidej, Garnpimol C

    2015-10-01

    The ophthalmic preparation of diclofenac sodium (DC) for relieving ocular inflammation is presently available in the market only as an eye drop solution. Due to its low occular bioavailability, it requires frequent application leading to low patients' compliance and quality of life. This study was conducted to develop formulations of DC loaded-N-trimethyl chitosan nanoparticles (DC-TMCNs) for ophthalmic use to improve ocular biavailabiltiy of DC. DC-TMCNs varied in formulation compositions were prepared using ionic gelation technique and evaluated for their physicochemical properties, drug release, eye irritation potential, and ophthalmic absorption of diclofenac sodium. N-Trimethyl chitosan (TMC) with a 49.8% degree of quaternization was synthesized and used for DC-TMCNs production. The obtained DC-TMCNs had particle size in a range of 130-190 nm with zeta potential values of +4 to +9 mV and drug entrapment efficiencies of more than 70% depending on the content of TMC and sodium tripolyphosphate (TPP). The optimized DC-TMCNs formulation contained TMC, DC, and TPP at a weight ratio of TMC/DC/TPP = 3:1:1. Their lyophilized product reconstituted with phosphate buffer solution pH 5.5 possessed a drug release pattern that fitted within the zero-order model. The eye irritation tests showed that DC-TMCNs were safe for ophthalmic use. The in vivo ophthalmic drug absorption study performed on rabbits indicated that DC-TMCNs could improve ophthalmic bioavailability of DC. Results of this study suggested that DC-TMCNs had potential for use as an alternative to conventional DC eye drops for ophthalmic inflammation treatment.

  12. 75 FR 18219 - Drug and Medical Device Forum on Food and Drug Administration Drug and Device Requirements and...

    Science.gov (United States)

    2010-04-09

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2010-N-0142] Drug and Medical Device Forum on Food and Drug Administration Drug and Device Requirements and Supplier Controls; Public Educational Forum AGENCY: Food and Drug Administration, HHS. ACTION: Notice of public...

  13. A Profile of Neuro-Ophthalmic Practice Around the World.

    Science.gov (United States)

    Frohman, Larry P

    2018-03-01

    To compare contrast neuro-ophthalmic practice in various countries, an 18-question survey was sent to the international North American Neuro-Ophthalmology Society (NANOS) members in the spring of 2016. At least 1 NANOS member was contacted for each non-US nation in the NANOS membership roster. If there were multiple NANOS members from 1 country, multiple were contacted. If responses were received from more than 1 person from a single country, the first response received was used as the source data. The survey (in English) was emailed to 47 NANOS members from 31 countries. Twenty responses were received representing members from 15 nations. In all 15 nations, at least half of the neuro-ophthalmologists were trained as ophthalmologists. In 60% of nations, at least half of the neuro-ophthalmologists were trained internally, whereas in 33% of countries, at least half were trained in the United States. The number of physicians who practiced a significant amount of neuro-ophthalmology ranged from low (0.08/million, India) to high (3.10/million, Israel). Countries having the highest percentage of neuro-ophthalmologists exclusively practicing neuro-ophthalmology also were those with better patient access to neuro-ophthalmic care. Requirement of approval to see a neuro-ophthalmologist or for imaging studies requested by neuro-ophthalmologists was not typical. In most nations, academic neuro-ophthalmologists were paid a straight salary. In no nation were neuro-ophthalmologists paid more than another ophthalmic subspecialty. Individual national health care system designs and compensation models have had a profound influence on the rewards and challenges that face neuro-ophthalmologists. There seems to have been a connection between recognition of the discipline, financial rewards of neuro-ophthalmic practice, conditions that permit full-time neuro-ophthalmic practice, and patient access to care. A higher percentage of gross national product for health care did not seem to

  14. Design of point-of-care (POC) microfluidic medical diagnostic devices

    Science.gov (United States)

    Leary, James F.

    2018-02-01

    Design of inexpensive and portable hand-held microfluidic flow/image cytometry devices for initial medical diagnostics at the point of initial patient contact by emergency medical personnel in the field requires careful design in terms of power/weight requirements to allow for realistic portability as a hand-held, point-of-care medical diagnostics device. True portability also requires small micro-pumps for high-throughput capability. Weight/power requirements dictate use of super-bright LEDs and very small silicon photodiodes or nanophotonic sensors that can be powered by batteries. Signal-to-noise characteristics can be greatly improved by appropriately pulsing the LED excitation sources and sampling and subtracting noise in between excitation pulses. The requirements for basic computing, imaging, GPS and basic telecommunications can be simultaneously met by use of smartphone technologies, which become part of the overall device. Software for a user-interface system, limited real-time computing, real-time imaging, and offline data analysis can be accomplished through multi-platform software development systems that are well-suited to a variety of currently available cellphone technologies which already contain all of these capabilities. Microfluidic cytometry requires judicious use of small sample volumes and appropriate statistical sampling by microfluidic cytometry or imaging for adequate statistical significance to permit real-time (typically medical decisions for patients at the physician's office or real-time decision making in the field. One or two drops of blood obtained by pin-prick should be able to provide statistically meaningful results for use in making real-time medical decisions without the need for blood fractionation, which is not realistic in the field.

  15. #DDOD Use Case: Consolidated reporting of medical device recalls

    Data.gov (United States)

    U.S. Department of Health & Human Services — SUMMARY DDOD use case request for consolidated, consistent reporting of medical device recalls. WHAT IS A USE CASE? A “Use Case” is a request that was made by the...

  16. A service protocol for post-processing of medical images on the mobile device

    Science.gov (United States)

    He, Longjun; Ming, Xing; Xu, Lang; Liu, Qian

    2014-03-01

    With computing capability and display size growing, the mobile device has been used as a tool to help clinicians view patient information and medical images anywhere and anytime. It is uneasy and time-consuming for transferring medical images with large data size from picture archiving and communication system to mobile client, since the wireless network is unstable and limited by bandwidth. Besides, limited by computing capability, memory and power endurance, it is hard to provide a satisfactory quality of experience for radiologists to handle some complex post-processing of medical images on the mobile device, such as real-time direct interactive three-dimensional visualization. In this work, remote rendering technology is employed to implement the post-processing of medical images instead of local rendering, and a service protocol is developed to standardize the communication between the render server and mobile client. In order to make mobile devices with different platforms be able to access post-processing of medical images, the Extensible Markup Language is taken to describe this protocol, which contains four main parts: user authentication, medical image query/ retrieval, 2D post-processing (e.g. window leveling, pixel values obtained) and 3D post-processing (e.g. maximum intensity projection, multi-planar reconstruction, curved planar reformation and direct volume rendering). And then an instance is implemented to verify the protocol. This instance can support the mobile device access post-processing of medical image services on the render server via a client application or on the web page.

  17. IN-SITU OPHTHALMIC GELS FOR THE TREATMENT OF EYE DISEASES

    OpenAIRE

    M. Jothi, S.L. Harikumar* and Geeta Aggarwal

    2012-01-01

    Topical administration of a drug in the conjunctival cul-de-sac is the treatment of choice for diseases of the anterior segment of eye. Development of ophthalmic drug delivery systems has always been challenging because of the drawbacks with this route, like non-productive absorption, drainage, induced lacrimation, tear turn over, impermeability of drugs to cornea. New approaches have been investigated for delivery of drugs to the eye by means of polymeric delivery of ophthalmic drugs to the ...

  18. 21 CFR 886.1690 - Pupillograph.

    Science.gov (United States)

    2010-04-01

    ... Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1690 Pupillograph. (a) Identification. A pupillograph is an AC-powered device intended to measure the pupil of the eye by reflected light and record the responses of the...

  19. [Hospital-based health technology assessment in France: how to proceed to evaluate innovative medical devices?].

    Science.gov (United States)

    Martelli, N; van den Brink, H; Denies, F; Dervaux, B; Germe, A F; Prognon, P; Pineau, J

    2014-01-01

    Innovative medical devices offer solutions to medical problems and greatly improve patients' outcomes. Like National Health Technology Assessment (HTA) agencies, hospitals face numerous requests for innovative and costly medical devices. To help local decision-makers, different approaches of hospital-based HTA (HB-HTA) have been adopted worldwide. The objective of the present paper is to explore HB-HTA models for adopting innovative medical devices in France and elsewhere. Four different models have been conceptualized: "ambassador" model, "mini-HTA" model, "HTA unit" model and "internal committee". Apparently, "HTA unit" and "internal committee" (or a mixture of both models) are the prevailing HB-HTA models in France. Nevertheless, some weaknesses of these models have been pointed out in previous works. Only few examples involving hospital pharmacists have been found abroad, except in France and in Italy. Finally, the harmonization of the assessment of innovative medical devices in France needs a better understanding of HB-HTA practices. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  20. Location of the internal carotid artery and ophthalmic artery segments for non-invasive intracranial pressure measurement by multi-depth TCD.

    Science.gov (United States)

    Hamarat, Yasin; Deimantavicius, Mantas; Kalvaitis, Evaldas; Siaudvytyte, Lina; Januleviciene, Ingrida; Zakelis, Rolandas; Bartusis, Laimonas

    2017-12-01

    The aim of the present study was to locate the ophthalmic artery by using the edge of the internal carotid artery (ICA) as the reference depth to perform a reliable non-invasive intracranial pressure measurement via a multi-depth transcranial Doppler device and to then determine the positions and angles of an ultrasonic transducer (UT) on the closed eyelid in the case of located segments. High tension glaucoma (HTG) patients and healthy volunteers (HVs) undergoing non-invasive intracranial pressure measurement were selected for this prospective study. The depth of the edge of the ICA was identified, followed by a selection of the depths of the IOA and EOA segments. The positions and angles of the UT on the closed eyelid were measured. The mean depth of the identified ICA edge for HTG patients was 64.3 mm and was 63.0 mm for HVs (p = 0.21). The mean depth of the selected IOA segment for HTG patients was 59.2 mm and 59.3 mm for HVs (p = 0.91). The mean depth of the selected EOA segment for HTG patients was 48.5 mm and 49.8 mm for HVs (p = 0.14). The difference in the located depths of the segments between groups was not statistically significant. The results showed a significant difference in the measured UT angles in the case of the identified edge of the ICA and selected ophthalmic artery segments (p = 0.0002). We demonstrated that locating the IOA and EOA segments can be achieved using the edge of the ICA as a reference point. OA: ophthalmic artery; IOA: intracranial segments of the ophthalmic artery; EOA: extracranial segments of the ophthalmic artery; ICA: internal carotid artery; UT: ultrasonic transducer; HTG: high tension glaucoma; SD: standard deviation; ICP: intracranial pressure; TCD: transcranial Doppler.

  1. Pediatric medical device development by surgeons via capstone engineering design programs.

    Science.gov (United States)

    Sack, Bryan S; Elizondo, Rodolfo A; Huang, Gene O; Janzen, Nicolette; Espinoza, Jimmy; Sanz-Cortes, Magdalena; Dietrich, Jennifer E; Hakim, Julie; Richardson, Eric S; Oden, Maria; Hanks, John; Haridas, Balakrishna; Hury, James F; Koh, Chester J

    2018-03-01

    There is a need for pediatric medical devices that accommodate the unique physiology and anatomy of pediatric patients that is increasingly receiving more attention. However, there is limited literature on the programs within children's hospitals and academia that can support pediatric device development. We describe our experience with pediatric device design utilizing collaborations between a children's hospital and two engineering schools. Utilizing the academic year as a timeline, unmet pediatric device needs were identified by surgical faculty and matched with an engineering mentor and a team of students within the Capstone Engineering Design programs at two universities. The final prototypes were showcased at the end of the academic year and if appropriate, provisional patent applications were filed. All twelve teams successfully developed device prototypes, and five teams obtained provisional patents. The prototypes that obtained provisional patents included a non-operative ureteral stent removal system, an evacuation device for small kidney stone fragments, a mechanical leech, an anchoring system of the chorio-amniotic membranes during fetal surgery, and a fetal oxygenation monitor during fetoscopic procedures. Capstone Engineering Design programs in partnership with surgical faculty at children's hospitals can play an effective role in the prototype development of novel pediatric medical devices. N/A - No clinical subjects or human testing was performed. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Wireless communication with implanted medical devices using the conductive properties of the body.

    Science.gov (United States)

    Ferguson, John E; Redish, A David

    2011-07-01

    Many medical devices that are implanted in the body use wires or wireless radiofrequency telemetry to communicate with circuitry outside the body. However, the wires are a common source of surgical complications, including breakage, infection and electrical noise. In addition, radiofrequency telemetry requires large amounts of power and results in low-efficiency transmission through biological tissue. As an alternative, the conductive properties of the body can be used to enable wireless communication with implanted devices. In this article, several methods of intrabody communication are described and compared. In addition to reducing the complications that occur with current implantable medical devices, intrabody communication can enable novel types of miniature devices for research and clinical applications.

  3. Post-market clinical research conducted by medical device manufacturers: a cross-sectional survey.

    Science.gov (United States)

    Ross, Joseph S; Blount, Katrina L; Ritchie, Jessica D; Hodshon, Beth; Krumholz, Harlan M

    2015-01-01

    In the US, once a medical device is made available for use, several requirements have been established by the US Food and Drug Administration (FDA) to ensure ongoing post-market surveillance of device safety and effectiveness. Our objective was to determine how commonly medical device manufacturers initiate post-market clinical studies or augment FDA post-market surveillance requirements for higher-risk devices that are most often approved via the FDA's pre-market approval (PMA) pathway. We conducted a cross-sectional survey of 47 manufacturers with operations in California, Minnesota, and Massachusetts who market devices approved via the PMA pathway. Among 22 respondents (response rate =47%), nearly all self-reported conducting post-market clinical research studies, commonly between 1 and 5; only 1 respondent reported never conducting post-market clinical research studies. While manufacturers most often engaged in these studies to satisfy FDA requirements, other reasons were reported, including performance monitoring and surveillance and market acceptance initiatives. Risks of conducting and not conducting post-market clinical research studies were described through open-ended response to questions. Medical device manufacturers commonly initiate post-market clinical studies at the request of the FDA. Clinical data from these studies should be integrated into national post-market surveillance initiatives.

  4. 78 FR 35940 - Content of Premarket Submissions for Management of Cybersecurity in Medical Devices; Draft...

    Science.gov (United States)

    2013-06-14

    ...] Content of Premarket Submissions for Management of Cybersecurity in Medical Devices; Draft Guidance for... draft guidance entitled ``Content of Premarket Submissions for Management of Cybersecurity in Medical Devices.'' This guidance identifies cybersecurity issues that manufacturers should consider in preparing...

  5. Efficacy of bromfenac sodium ophthalmic solution for treatment of dry eye disease.

    Science.gov (United States)

    Fujishima, Hiroshi; Fuseya, Miki; Ogata, Masarou; Murat, Dogru

    2015-01-01

    To evaluate the efficacy of bromfenac sodium ophthalmic solution (BF) in patients with dry eye disease (DED) inadequately controlled by monotherapy with artificial tears (ATs). An investigator-oriented trial with a single-arm, nonrandomized, open-label design. Twenty-six patients, who showed no symptomatic improvement of DED after 1 month of AT treatment, were enrolled. Bromfenac sodium ophthalmic solution was administered adjunctively with AT for 1 month. The BF treatment was then discontinued, and AT treatment alone was continued for 3 months. The signs and symptoms were evaluated at the beginning of BF treatment (Pre), at the end of the combined BF and AT treatment (BF1M), and at 1 and 3 months after discontinuation of BF treatment (Po1M and Po3M, respectively). The dryness scores at BF1M were significantly improved compared with Pre (P ophthalmic solution has improved the dryness of the eye and signs of DED through its anti-inflammatory effects. Nonsteroidal anti-inflammatory drugs were suitable as anti-inflammatory ophthalmic solutions for patients with DED.

  6. Ophthalmic Drug Delivery Systems for Antibiotherapy—A Review

    Science.gov (United States)

    Dubald, Marion; Bourgeois, Sandrine; Andrieu, Véronique; Fessi, Hatem

    2018-01-01

    The last fifty years, ophthalmic drug delivery research has made much progress, challenging scientists about the advantages and limitations of this drug delivery approach. Topical eye drops are the most commonly used formulation in ocular drug delivery. Despite the good tolerance for patients, this topical administration is only focus on the anterior ocular diseases and had a high precorneal loss of drugs due to the tears production and ocular barriers. Antibiotics are popularly used in solution or in ointment for the ophthalmic route. However, their local bioavailability needs to be improved in order to decrease the frequency of administrations and the side effects and to increase their therapeutic efficiency. For this purpose, sustained release forms for ophthalmic delivery of antibiotics were developed. This review briefly describes the ocular administration with the ocular barriers and the currently topical forms. It focuses on experimental results to bypass the limitations of ocular antibiotic delivery with new ocular technology as colloidal and in situ gelling systems or with the improvement of existing forms as implants and contact lenses. Nanotechnology is presently a promising drug delivery way to provide protection of antibiotics and improve pathway through ocular barriers and deliver drugs to specific target sites. PMID:29342879

  7. Ophthalmic Drug Delivery Systems for Antibiotherapy—A Review

    Directory of Open Access Journals (Sweden)

    Marion Dubald

    2018-01-01

    Full Text Available The last fifty years, ophthalmic drug delivery research has made much progress, challenging scientists about the advantages and limitations of this drug delivery approach. Topical eye drops are the most commonly used formulation in ocular drug delivery. Despite the good tolerance for patients, this topical administration is only focus on the anterior ocular diseases and had a high precorneal loss of drugs due to the tears production and ocular barriers. Antibiotics are popularly used in solution or in ointment for the ophthalmic route. However, their local bioavailability needs to be improved in order to decrease the frequency of administrations and the side effects and to increase their therapeutic efficiency. For this purpose, sustained release forms for ophthalmic delivery of antibiotics were developed. This review briefly describes the ocular administration with the ocular barriers and the currently topical forms. It focuses on experimental results to bypass the limitations of ocular antibiotic delivery with new ocular technology as colloidal and in situ gelling systems or with the improvement of existing forms as implants and contact lenses. Nanotechnology is presently a promising drug delivery way to provide protection of antibiotics and improve pathway through ocular barriers and deliver drugs to specific target sites.

  8. 21 CFR 886.1880 - Fusion and stereoscopic target.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fusion and stereoscopic target. 886.1880 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1880 Fusion and stereoscopic target. (a) Identification. A fusion and stereoscopic target is a device intended for use as a viewing object...

  9. 21 CFR 886.1390 - Flexible diagnostic Fresnel lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Flexible diagnostic Fresnel lens. 886.1390 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1390 Flexible diagnostic Fresnel lens. (a) Identification. A flexible diagnostic Fresnel lens is a device that is a very thin lens which has...

  10. 21 CFR 886.1510 - Eye movement monitor.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Eye movement monitor. 886.1510 Section 886.1510...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1510 Eye movement monitor. (a) Identification. An eye movement monitor is an AC-powered device with an electrode intended to measure and record...

  11. 21 CFR 886.4070 - Powered corneal burr.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES OPHTHALMIC DEVICES Surgical Devices § 886.4070 Powered corneal burr. (a) Identification. A powered corneal burr is an AC-powered or battery-powered device that is a motor and drilling tool intended to remove rust rings from the cornea of the eye. (b) Classification. Class I (general controls). When...

  12. Wireless energy transfer platform for medical sensors and implantable devices.

    Science.gov (United States)

    Zhang, Fei; Hackworth, Steven A; Liu, Xiaoyu; Chen, Haiyan; Sclabassi, Robert J; Sun, Mingui

    2009-01-01

    Witricity is a newly developed technique for wireless energy transfer. This paper presents a frequency adjustable witricity system to power medical sensors and implantable devices. New witricity resonators are designed for both energy transmission and reception. A prototype platform is described, including an RF power source, two resonators with new structures, and inductively coupled input and output stages. In vitro experiments, both in open air and using a human head phantom consisting of simulated tissues, are employed to verify the feasibility of this platform. An animal model is utilized to evaluate in vivo energy transfer within the body of a laboratory pig. Our experiments indicate that witricity is an effective new tool for providing a variety of medical sensors and devices with power.

  13. Ophthalmic Start-Up Chief Executive Officers' Perceptions of Development Hurdles.

    Science.gov (United States)

    Stewart, William C; Nelson, Lindsay A; Kruft, Bonnie; Stewart, Jeanette A

    2018-01-01

    To identify current challenges facing ophthalmic pharmaceutical start-ups in developing new products. Surveys were distributed to the chief executive officer (CEO) or president of ophthalmic start-ups. The survey attracted 24 responses from 78 surveys distributed (31%). The CEOs stated that a lack of financial capital (n = 18, 75%), FDA regulations (n = 6, 25%), and failure to meet clinical endpoints (n = 6, 25%) were their greatest development hurdles. Risk aversion to medicines in early development (n = 18, 75%), mergers and acquisitions reducing corporate choice for licensing agreements (n = 7, 29%), the emergence of large pharmaceutical-based venture capital funding groups (n = 12, 50%), and the failure of many large pharmaceutical companies to develop their own medicines (n = 10, 42%) were noted as recent prominent trends affecting fundraising. The study suggests that development funding, regulatory burden, and meeting clinical endpoints are the greatest development challenges faced by ophthalmic start-up CEOs. © 2017 S. Karger AG, Basel.

  14. Formulation and stability of an extemporaneous 0.02% chlorhexidine digluconate ophthalmic solution

    Directory of Open Access Journals (Sweden)

    Shu-Chiao Lin

    2015-12-01

    Conclusion: The acetate-buffered 0.02% chlorhexidine digluconate ophthalmic solution stored in light-resistant high-density polyethylene eyedroppers demonstrated excellent stability at 2–25°C for 6 months after being sealed and for 1 month after opening. This finding will enable us to prepare 0.02% chlorhexidine digluconate ophthalmic solutions based on a doctor's prescription.

  15. BORDERLINE AND CLASSIFICATION IN THE COMMUNITY REGULATORY FRAMEWORK FOR MEDICAL DEVICES – BRIEF REVIEW ON SOME DENTISTRY PRODUCTS.

    Directory of Open Access Journals (Sweden)

    Maya Lyapina

    2015-02-01

    Full Text Available Defining a given product as a medical device and interpretation of the application of the classification rules fall within the competence of the competent authorities of the Member States where the product is on the market. Different interpretations of Community legislation occur, and, can put public health at risk and distort the internal market. Borderline cases are considered to be those cases where it is not clear from the outset whether a given product is a medical device, an in vitro diagnostic medical device, an active implantable medical device or not. Classification cases can be described as those cases where there exists a difficulty in the uniform application of the classification rules as laid down in the Medical Devices Directive (MDD, or where for a given device, depending on interpretation of the rules, different classifications can occur. The aim of the present work is to make a brief review on discussion on classification in the community regulatory framework for medical devices of some dentistry products.

  16. The Biological Responses to Magnesium-Based Biodegradable Medical Devices

    Directory of Open Access Journals (Sweden)

    Lumei Liu

    2017-11-01

    Full Text Available The biocompatibility of Magnesium-based materials (MBMs is critical to the safety of biodegradable medical devices. As a promising metallic biomaterial for medical devices, the issue of greatest concern is devices’ safety as degrading products are possibly interacting with local tissue during complete degradation. The aim of this review is to summarize the biological responses to MBMs at the cellular/molecular level, including cell adhesion, transportation signaling, immune response, and tissue growth during the complex degradation process. We review the influence of MBMs on gene/protein biosynthesis and expression at the site of implantation, as well as throughout the body. This paper provides a systematic review of the cellular/molecular behavior of local tissue on the response to Mg degradation, which may facilitate a better prediction of long-term degradation and the safe use of magnesium-based implants through metal innovation.

  17. Communication during pediatric asthma visits and child asthma medication device technique 1 month later.

    Science.gov (United States)

    Sleath, Betsy; Carpenter, Delesha M; Ayala, Guadalupe X; Williams, Dennis; Davis, Stephanie; Tudor, Gail; Yeatts, Karin; Gillette, Chris

    2012-11-01

    This study investigated how provider demonstration of and assessment of child use of asthma medication devices and certain aspects of provider-patient communication during medical visits is associated with device technique 1 month later. Two hundred and ninety-six children aged 8-16 years with persistent asthma and their caregivers were recruited at five North Carolina pediatric practices. All of the medical visits were audio-tape recorded. Children were interviewed 1 month later and their device technique was observed and rated. If the provider asked the child to demonstrate metered dose inhaler technique during the medical visit, then the child was significantly more likely to perform a greater percentage of inhaler steps correctly 1 month later. Children with higher asthma management self-efficacy scores were significantly more likely to perform a greater percentage of diskus steps correctly. Additionally, children were significantly more likely to perform a greater percentage of diskus steps correctly if the provider discussed a written action plan during the visit. Children were significantly more likely to perform a greater percentage of turbuhaler steps correctly if they asked more medication questions. Providers should ask children to demonstrate their inhaler technique during medical visits so that they can educate children about proper technique and improve child asthma management self-efficacy. Providers should encourage children to ask questions about asthma medication devices during visits and they should discuss asthma action plans with families.

  18. French Sizing of Medical Devices is not Fit for Purpose

    International Nuclear Information System (INIS)

    Kibriya, Nabil; Hall, Rebecca; Powell, Steven; How, Thien; McWilliams, Richard G.

    2013-01-01

    PurposeThe purpose of the study is to quantify the variation in the metric equivalent of French size in a range of medical devices, from various manufacturers, used in interventional radiology.MethodsThe labelling of a range of catheters, introducers, drains, balloons, stents, and endografts was examined. Products were chosen to achieve a broad range of French sizes from several manufacturers. To assess manufacturing accuracy, eight devices were selected for measurement using a laser micrometer. The external diameters of three specimens of each device were measured at centimeter intervals along the length of the device to ensure uniformity.ResultsA total of 200 labels of interventional radiology equipment were scrutinized. The results demonstrate a wide variation in the metric equivalent of French sizing. Labelled products can vary in diameter across the product range by up to 0.79 mm.The devices selected for measurement with the non-contact laser micrometer demonstrate acceptable manufacturing consistency. The external diameter differed by 0.05 mm on average.ConclusionsOur results demonstrate wide variation in the interpretation of the French scale by different manufacturers of medical devices. This has the potential to lead to problems using coaxial systems especially when the products are from different manufacturers. It is recommended that standard labelling should be employed by all manufacturers conveying specific details of the equipment. Given the wide variation in the interpretation of the French scale, our opinion is that this scale either needs to be abandoned or be strictly defined and followed

  19. 77 FR 38177 - TRICARE; Off-Label Uses of Devices; Partial List of Examples of Unproven Drugs, Devices, Medical...

    Science.gov (United States)

    2012-06-27

    ... drugs, devices, and medical treatments or procedures and adding the TRICARE definition of unlabeled or... labeling. We are now modifying the definition of ``unlabeled or off-label drug'' to ``off-label use of a... reference back to the definition of the term in 199.2. ``Off-label uses of drugs and devices'' includes off...

  20. 75 FR 20854 - Medical Device Use in the Home Environment: Implications for the Safe and Effective Use of...

    Science.gov (United States)

    2010-04-21

    ...] Medical Device Use in the Home Environment: Implications for the Safe and Effective Use of Medical Device... related to the safe and effective use of medical device technology in the home environment. The workshop... the home environment. FDA will solicit feedback on: 1. The agency's current working definition of...

  1. Medical devices and the Middle East: market, regulation, and reimbursement in Gulf Cooperation Council states.

    Science.gov (United States)

    Howard, Jason J

    2014-01-01

    With some of the richest economies in the world, the Gulf Cooperation Council (GCC) is undergoing rapid growth not only in its population but also in health care expenditure. Despite the GCC's abundance of hydrocarbon-based wealth, the drivers of the medical device industry in the GCC are still in flux, with gains yet to be made in areas of infrastructure, regulation, and reimbursement. However, the regional disease burden, expanding health insurance penetration, increasing privatization, and a desire to attract skilled expatriate health care providers have led to favorable conditions for the medical device market in the GCC. The purpose of this article is to investigate the current state of the GCC medical device industry, with respect to market, regulation, and reimbursement, paying special attention to the three largest medical device markets: Saudi Arabia, the United Arab Emirates, and Qatar. The GCC would seem to represent fertile ground for the development of medical technologies, especially those in line with the regional health priorities of the respective member states.

  2. Medical Device-Associated Candida Infections in a Rural Tertiary Care Teaching Hospital of India

    Directory of Open Access Journals (Sweden)

    Sachin C. Deorukhkar

    2016-01-01

    Full Text Available Health care associated infections (HCAIs add incrementally to the morbidity, mortality, and cost expected of the patient’s underlying diseases alone. Approximately, about half all cases of HCAIs are associated with medical devices. As Candida medical device-associated infection is highly drug resistant and can lead to serious life-threatening complications, there is a need of continuous surveillance of these infections to initiate preventive and corrective measures. The present study was conducted at a rural tertiary care hospital of India with an aim to evaluate the rate of medical device-associated Candida infections. Three commonly encountered medical device-associated infections (MDAI, catheter-associated urinary tract infection (CA-UTI, intravascular catheter-related blood stream infections (CR-BSI, and ventilator-associated pneumonia (VAP, were targeted. The overall rate of MDAI in our hospital was 2.1 per 1000 device days. The rate of Candida related CA-UTI and CR-BSI was noted as 1.0 and 0.3, respectively. Untiring efforts taken by team members of Hospital Acquired Infection Control Committee along with maintenance of meticulous hygiene of the hospital and wards may explain the low MDAI rates in our institute. The present surveillance helped us for systematic generation of institutional data regarding MDAI with special reference to role of Candida spp.

  3. Compiling a Medical Device File and a Proposal for an International Standard for Rehabilitation Robots

    NARCIS (Netherlands)

    Römer, GertWillem R.B.E.; Stuyt, Harry J.A.

    2007-01-01

    Medical devices produced by manufacturers are subject to regulatory review by authorities. Usually, medical devices are developed at universities and other research institutes. This implies that regulatory activities are to be carried out by the designer at these organizations also. And as early as

  4. 78 FR 56719 - Challenging Regulatory and Reimbursement Paradigms for Medical Devices in the Treatment of...

    Science.gov (United States)

    2013-09-13

    ...] Challenging Regulatory and Reimbursement Paradigms for Medical Devices in the Treatment of Metabolic Diseases... announcing a public workshop entitled ``Changing Regulatory and Reimbursement Paradigms for Medical Devices... registration information on the AGA Web site. If you need special accommodations due to a disability, please...

  5. Use of traditional eye medicine and self-medication in rural India: A population-based study.

    Science.gov (United States)

    Gupta, Noopur; Vashist, Praveen; Tandon, Radhika; Gupta, Sanjeev K; Kalaivani, Mani; Dwivedi, S N

    2017-01-01

    To determine the type and nature of traditional eye medicine (TEM), their sources and use and practices related to self-medication for ophthalmic diseases in a rural Indian population. A population-based, cross-sectional study was conducted in 25 randomly selected clusters of Rural Gurgaon, Haryana, India as part of CORE (Cornea Opacity Rural Epidemiological) study. In addition to comprehensive ophthalmic examination, health-seeking behavior and use of self-medication and TEM was assessed in the adult population using a semi-structured questionnaire. Physical verification of available ophthalmic medications in the enumerated households was conducted by the study team. Descriptive statistics were computed along with multivariable logistic regression analysis to determine associated factors for use of self-medication and TEM. Of the 2160 participants interviewed, 396 (18.2%) reported using ophthalmic medications without consulting an ophthalmologist, mainly for symptoms like watering (37.1%), redness (27.7%), itching (19.2%) and infection (13.6%). On physical verification of available eye drops that were being used without prescription, 26.4% participants were practicing self-medication. Steroid, expired/unlabeled and indigenous eye drops were being used by 151(26.5%), 120(21.1%) and 75 (13.2%) participants respectively. Additionally, 25.7% (529) participants resorted to home remedies like 'kajal'(61.4%), honey (31.4%), ghee (11.7%) and rose water (9.1%). Use of TEM is prevalent in this population. The rampant use of steroid eye drops without prescription along with use of expired or unlabelled eye drops warrants greater emphasis on safe eye care practices in this population. Public awareness and regulatory legislations must be implemented to decrease harmful effects arising due to such practices.

  6. Medical Device Integrated Vital Signs Monitoring Application with Real-Time Clinical Decision Support.

    Science.gov (United States)

    Moqeem, Aasia; Baig, Mirza; Gholamhosseini, Hamid; Mirza, Farhaan; Lindén, Maria

    2018-01-01

    This research involves the design and development of a novel Android smartphone application for real-time vital signs monitoring and decision support. The proposed application integrates market available, wireless and Bluetooth connected medical devices for collecting vital signs. The medical device data collected by the app includes heart rate, oxygen saturation and electrocardiograph (ECG). The collated data is streamed/displayed on the smartphone in real-time. This application was designed by adopting six screens approach (6S) mobile development framework and focused on user-centered approach and considered clinicians-as-a-user. The clinical engagement, consultations, feedback and usability of the application in the everyday practices were considered critical from the initial phase of the design and development. Furthermore, the proposed application is capable to deliver rich clinical decision support in real-time using the integrated medical device data.

  7. 21 CFR 349.14 - Ophthalmic emollients.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Ophthalmic emollients. 349.14 Section 349.14 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR.... (4) Petrolatum, up to 100 percent. (5) White ointment, up to 100 percent. (6) White petrolatum, up to...

  8. 21 CFR 886.1400 - Maddox lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Maddox lens. 886.1400 Section 886.1400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1400 Maddox lens. (a) Identification. A Maddox lens is a device...

  9. 21 CFR 886.5844 - Prescription spectacle lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Prescription spectacle lens. 886.5844 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5844 Prescription spectacle lens. (a) Identification. A prescription spectacle lens is a glass or plastic device that is a lens intended to be worn by...

  10. 21 CFR 886.5540 - Low-vision magnifier.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Low-vision magnifier. 886.5540 Section 886.5540...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5540 Low-vision magnifier. (a) Identification. A low-vision magnifier is a device that consists of a magnifying lens intended for use by a patient...

  11. 21 CFR 886.5870 - Low-vision telescope.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Low-vision telescope. 886.5870 Section 886.5870...) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5870 Low-vision telescope. (a) Identification. A low-vision telescope is a device that consists of an arrangement of lenses or mirrors intended for...

  12. Radiation as a microbiological contamination control of drugs, cosmetics and medical devices

    International Nuclear Information System (INIS)

    Ishizeki, Chuichi

    1985-01-01

    This paper deals with current status of radiation sterilization or disinfection of drugs, cosmetics, their materials, and medical devices, and with quality control as a tool for securing microbiological safety, especially current status of sterilization tests. Ointment containing tetracyclin, steroid hormones, gelatin, and enzymes are presented as drug samples to be irradiated, and explanations for radiation sterilization of these drugs are provided. An outline of the application of radiation in cosmetics and medical devices is given. Issues are also provided from the viewpoint of safey and effectiveness of radiation sterilization. (Namekawa, K.)

  13. Limited Awareness of the Essences of Certification or Compliance Markings on Medical Devices.

    Science.gov (United States)

    Foo, Jong Yong Abdiel; Tan, Xin Ji Alan

    2017-06-01

    Medical devices have been long used for odiagnostic, therapeutic or rehabilitation purposes. Currently, they can range from a low-cost portable device that is often used for personal health monitoring to high-end sophisticated equipment that can only be operated by trained professionals. Depending on the functional purposes, there are different certification or compliance markings on the device when it is sold. One common certification marking is the Conformité Européenne affixation but this has a range of certification mark numbering for a variety of functional purposes. While the regulators and medical device manufacturers understand the associated significance and clinical implications, these may not be apparent to the professionals (using or maintaining the device) and the general public. With portable healthcare devices and mobile applications gaining popularity, better awareness of certification marking will be needed. Particularly, there are differences in the allowed functional purposes and the associated cost derivations of devices with a seemingly similar nature. A preferred approach such as an easy-to-understand notation next to any certification marking on a device can aid in differentiation without the need to digest mountainous regulatory details.

  14. Absorbed doses to the main parts of eyeball due to use 90Sr + 90Y ophthalmic applicator

    International Nuclear Information System (INIS)

    Chen Lishu

    1993-05-01

    The ophthalmic radiotherapy dosimetry and some affecting factors are introduced. The distributions of absorbed doses to the main parts of a fresh eyeball such as the cornea, sclera, lens and anterior chamber, during the radiotherapy by using a 90 Sr + 90 Y ophthalmic applicator are presented. An tissue-equivalent extrapolation ionization chamber was used in the dose measurement. The reasonable doses during ophthalmic radiotherapy for different depths have been obtained. Therefore, the absorbed dose to the lens, the most sensitive organ, can be given. These data are useful for radiation protection in ophthalmic radiotherapy

  15. Feasibility of energy harvesting techniques for wearable medical devices.

    Science.gov (United States)

    Voss, Thaddaeus J; Subbian, Vignesh; Beyette, Fred R

    2014-01-01

    Wearable devices are arguably one of the most rapidly growing technologies in the computing and health care industry. These systems provide improved means of monitoring health status of humans in real-time. In order to cope with continuous sensing and transmission of biological and health status data, it is desirable to move towards energy autonomous systems that can charge batteries using passive, ambient energy. This not only ensures uninterrupted data capturing, but could also eliminate the need to frequently remove, replace, and recharge batteries. To this end, energy harvesting is a promising area that can lead to extremely power-efficient portable medical devices. This paper presents an experimental prototype to study the feasibility of harvesting two energy sources, solar and thermoelectric energy, in the context of wearable devices. Preliminary results show that such devices can be powered by transducing ambient energy that constantly surrounds us.

  16. Dosimetric studies for gamma radiation validation of medical devices

    International Nuclear Information System (INIS)

    Soliman, Y.S.; Beshir, W.B.; Abdel-Fattah, A.A.; Abdel-Rehim, F.

    2013-01-01

    The delivery and validation of a specified dose to medical devices are key concerns to operators of gamma radiation facilities. The objective of the present study was to characterize the industrial gamma radiation facility and map the dose distribution inside the product-loading pattern during the validation and routine control of the sterilization process using radiochromic films. Cardboard phantoms were designed to achieve the homogeneity of absorbed doses. The uncertainty of the dose delivered during validation of the sterilization process was assessed. - Highlights: ► Using γ-rays for sterilization of hollow fiber dialyzers and blood tubing sets according to ISO 11137, 2006. ► Dosimetry studies of validations of γ-irradiation facility and sterilized medical devices. ► Places of D min and D max have been determined using FWT-60 films. ► Determining the target minimum doses required to meet the desired SAL of 10 −6 for the two products.

  17. 21 CFR 886.1360 - Visual field laser instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Visual field laser instrument. 886.1360 Section 886.1360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1360 Visual field laser instrument...

  18. 21 CFR 886.1150 - Visual acuity chart.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Visual acuity chart. 886.1150 Section 886.1150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1150 Visual acuity chart. (a) Identification...

  19. Effect of textured eye drop bottles on the photostability of pranoprofen 0.1% ophthalmic solution.

    Science.gov (United States)

    Iwatsuka, Kinya; Inada, Katsuhiro; Ueoka, Hiroki; Otsuka, Tadashi; Maeda, Masaki; Yamaguchi, Masazumi; Yasueda, Shin-ichi

    2015-01-01

    Ophthalmic solutions are usually filled in a plastic bottle due to its durability and disposability. In Japan, photostability is one of the concerns for the quality control because an eye drop bottle must be a transparent container. The present work studied the effect of textured eye drop bottles on its light blocking to improve the photostability of ophthalmic solutions. We investigated the photostability of Pranoprofen ophthalmic solution filled in a variety of textured eye drop bottles. Pranoprofen content was analyzed by high-performance liquid chromatography and surface structure of textured eye drop bottles was evaluated by transmittance, calculated average roughness (Ra) and haze intensity. We observed that eye drop bottle which had greater than Ra value of 1.0 µm and haze intensity 62% clearly showed photostability improvement. This report is the first one which shows that photostability of ophthalmic solution is improved by using textured eye drop bottle. Moreover, this approach is a simple and effective method to improve the photostability. This method is available for not only various ophthalmic applications but also other liquid pharmaceuticals or food products.

  20. Dural AVM supplied by the ophthalmic artery.

    LENUS (Irish Health Repository)

    Flynn, T H

    2012-02-03

    Dural arteriovenous malformations in the anterior cranial fossa are rare and are especially prone to haemorrhage. These lesions are usually treated by surgical excision. We report the embolization of an anterior cranial fossa DAVM using an endovascular approach via the ophthalmic artery.

  1. Field Safety Notes in Product Problems of Medical Devices for Use in Pulmonology.

    Science.gov (United States)

    Hannig, Jürgen; Siekmeier, Rüdiger

    2015-01-01

    The current European system for medical devices is governed by three EC directives: the Medical Device Directive 93/42/EEC, the In-Vitro Diagnostic Directive 98/79/EC and the Active Implantable Medical Device Directive 90/385/EEC and regulates marketing and post-market surveillance of medical devices in the European Economic Area. In cases of incidents and field safety corrective actions (FSCA) manufacturers have to inform the responsible Competent Authority, which is the Federal Institute for Drugs and Medical Devices (BfArM) and the public by field safety notices (FSN). In this study we analyzed FSN of medical devices exclusively serving for diagnostics or treatment in pulmonology (e.g. nebulizers, oxygen concentrators, pulse oximeters, lung function analyzers, and non-active devices for treatment). FSCA and FSN publicized by BfArM in 2005-2013 were analyzed in respect to the MEDDEV 2.12-1 rev 8. In total 41 FSCA were publicized for the included products. German and English FSN were found in 36/35 cases, respectively. FSN were clearly characterized as FSN in 22/20 cases and declaration of the type of action was found in 27/26 cases, respectively. Product names were provided in all cases. Lot numbers or other information for product characterization were available in 7/8 and 26/24 cases, respectively. Detailed information regarding FSCA and product malfunction were found in 27/33 and 36/35 cases, respectively. Information on product related risks with previous use of the affected product was provided in 24/23 cases. In 34/34 cases manufacturers provided information to mitigate product related risks. Requests to pass FSN to persons needing awareness were found in 10/14 cases. Contact data were provided in 30/30 cases. Confirmation that the Competent Authority was informed was found in 12/14 cases and in 19/18 cases a customer confirmation was included. The obtained data suggest that there is an increasing annual number of FSCA and most FSN fulfill the criteria of

  2. Superior ophthalmic vein enlargement and increased muscle index in dysthyroid optic neuropathy.

    Science.gov (United States)

    Lima, Breno da Rocha; Perry, Julian D

    2013-01-01

    To compare superior ophthalmic vein diameter and extraocular muscle index in patients with thyroid eye disease with or without optic neuropathy. High-resolution CT scan images of 40 orbits of 20 patients with history of thyroid eye disease (with or without optic neuropathy), who underwent orbital decompression surgery from January 2007 to November 2009, were retrospectively reviewed. Superior ophthalmic vein diameter was measured in coronal and axial planes. Extraocular muscle index was calculated according to the method proposed by Barrett et al. The clinical diagnosis of optic neuropathy was based on characteristic signs that included afferent pupillary defect, decreased visual acuity, visual field defects, and dyschromatopsia. Orbits were divided in 2 groups based on presence or absence of optic neuropathy. Superior ophthalmic vein diameter was significantly higher in orbits with concomitant optic neuropathy (mean 2.4 ± 0.4mm, p optic neuropathy (mean 57.9% ± 5.7%, p = 0.0002). Muscle index greater than 50% was present in all patients with dysthyroid optic neuropathy. This study suggests that patients with thyroid eye disease with enlarged superior ophthalmic vein and increased extraocular muscle index are more likely to have concomitant optic neuropathy.

  3. BioInnovate Ireland--fostering entrepreneurial activity through medical device innovation training.

    Science.gov (United States)

    Bruzzi, M S; Linehan, J H

    2013-09-01

    In the midst of a rich environment for medical device development and manufacturing, universities can play a critical role by developing relevant training programs to produce entrepreneurs who can be efficient and successful in creating early stage companies by understanding deeply the issues involved in creating a useful device, how to raise money, designing early clinical studies and locating manufacturing partners.

  4. Effects of viscoelastic ophthalmic solutions on cell cultures

    Directory of Open Access Journals (Sweden)

    Madhavan Hajib

    1998-01-01

    Full Text Available The development of mild but significant inflammation probably attributable to viscoelastic ophthalmic solutions in cataract surgery was recently brought to the notice of the authors, and hence a study of the effects of these solutions available in India, on cell cultures was undertaken. We studied the effects of 6 viscoelastic ophthalmic solutions (2 sodium hyaluronate designated as A and B, and 4 hydroxypropylmethylcellulose designated as C, D, E and F on HeLa, Vero and BHK-21 cell lines in tissue culture microtitre plates using undiluted, 1:10 and 1:100 dilutions of the solutions, and in cover slip cultures using undiluted solutions. Phase contrast microscopic examination of the solutions was also done to determine the presence of floating particles. The products D and F produced cytotoxic changes in HeLa cell line and these products also showed the presence of floating particles under phase contrast microscopy. Other products did not have any adverse effects on the cell lines nor did they show floating particles. The viscoelastic ophthalmic pharmaceutical products designated D and F have cytotoxic effects on HeLa cell line which appears to be a useful cell line for testing these products for their toxicity. The presence of particulate materials in products D and F indicates that the methods used for purification of the solution are not effective.

  5. Hacking medical devices a review - biomed 2013.

    Science.gov (United States)

    Frenger, Paul

    2013-01-01

    Programmable, implantable and external biomedical devices (such as pacemakers, defibrillators, insulin pumps, pain management pumps, vagus nerve stimulators and others) may be vulnerable to unauthorized access, commonly referred to as “hacking”. This intrusion may lead to compromise of confidential patient data or loss of control of the device itself, which may be deadly. Risks to health from unauthorized access is in addition to hazards from faulty (“buggy”) software or circuitry. Historically, this aspect of medical device design has been underemphasized by both manufacturers and regulatory bodies until recently. However, an insulin pump was employed as a murder weapon in 2001 and successful hacking of an implantable defibrillator was demonstrated in 2008. To remedy these problems, professional groups have announced a variety of design standards and the governmental agencies of several countries have enacted device regulations. In turn, manufacturers have developed new software products and hardware circuits to assist biomedical engineering firms to improve their commercial offerings. In this paper the author discusses these issues, reviewing known problems and zero-day threats, with potential solutions. He outlines his approach to secure software and hardware challenges using the Forth language. A plausible scenario is described in which hacking of an implantable defibrillator by terrorists results in a severe national security threat to the United States.

  6. Monitoring of biofilm formation on different material surfaces of medical devices using hyperspectral imaging method

    Science.gov (United States)

    Kim, Do-Hyun; Kim, Moon S.; Hwang, Jeeseong

    2012-03-01

    Contamination of the inner surface of indwelling (implanted) medical devices by microbial biofilm is a serious problem. Some microbial bacteria such as Escherichia coli form biofilms that lead to potentially lifethreatening infections. Other types of medical devices such as bronchoscopes and duodenoscopes account for the highest number of reported endoscopic infections where microbial biofilm is one of the major causes for these infections. We applied a hyperspectral imaging method to detect biofilm contamination on the surface of several common materials used for medical devices. Such materials include stainless steel, titanium, and stainless-steeltitanium alloy. Potential uses of hyperspectral imaging technique to monitor biofilm attachment to different material surfaces are discussed.

  7. 21 CFR 886.1395 - Diagnostic Hruby fundus lens.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Diagnostic Hruby fundus lens. 886.1395 Section 886...) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1395 Diagnostic Hruby fundus lens. (a) Identification. A diagnostic Hruby fundus lens is a device that is a 55 diopter lens intended for use in the...

  8. State of the art of medical devices featuring smart electro-rheological and magneto-rheological fluids

    Directory of Open Access Journals (Sweden)

    Jong-Seok Oh

    2017-10-01

    Full Text Available Recently, smart fluids have drawn significant attention and growing a great interest in a broad range of engineering applications such as automotive and medical areas. In this article, two smart fluids called electro-rheological (ER fluid and magneto-rheological (MR fluid are reviewed in terms of medical applications. Especially, this article describes the attributes and inherent properties of individual medical and rehabilitation devices. The devices surveyed in this article include multi-degree-of-freedom haptic masters for robot surgery, thin membrane touch panels for braille readers, sponge-like tactile sensors to feel human tissues such as liver, rehabilitation systems such as prosthetic leg, and haptic interfaces for dental implant surgery. The operating principle, inherent characteristics and practical feasibility of each medical device or system are fully discussed in details.

  9. 21 CFR 349.12 - Ophthalmic demulcents.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 5 2010-04-01 2010-04-01 false Ophthalmic demulcents. 349.12 Section 349.12 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DRUGS FOR....2 to 1 percent. (5) Propylene glycol, 0.2 to 1 percent. (e) Polyvinyl alcohol, 0.1 to 4 percent. (f...

  10. Ophthalmic implications of seasonal affective disorder

    International Nuclear Information System (INIS)

    Paramore, J.E.; King, V.M.

    1989-01-01

    A review of seasonal affective disorder (SAD) is presented with a discussion of its standard treatment of phototherapy. A number of ophthalmic implications related to SAD are proposed. These implications relate to both the condition and the phototherapy used in its treatment, especially the use of full spectrum light which contains ultraviolet and near ultraviolet radiation. 12 references

  11. Practical design control implementation for medical devices

    CERN Document Server

    Justiniano, Jose

    2003-01-01

    Bringing together the concepts of design control and reliability engineering, this book is a must for medical device manufacturers. It helps them meet the challenge of designing and developing products that meet or exceed customer expectations and also meet regulatory requirements. Part One covers motivation for design control and validation, design control requirements, process validation and design transfer, quality system for design control, and measuring design control program effectiveness. Part Two discusses risk analysis and FMEA, designing-in reliability, reliability and design verific

  12. Medical Device Plug-and-Play Interoperability Standards and Technology Leadership

    Science.gov (United States)

    2016-10-01

    death,” The Boston Globe, April 3 2010. 27. Arney D, Pajic M, Goldman JM, Lee I, Mangharam R, Sokolsky O, “Toward Patient Safety in Closed - Loop Medical ...becoming increasingly clear. We have been providing medical device interoperability domain expertise to assist the Veterans Administration in a...15. Wallroth C, Goldman J, Manigel J, Osborn D, Roellike T, Weininger S, Westenskow D, “Development of a Standard for Physiologic Closed Loop

  13. [Biological availability of ophthalmic drugs. 1. Increasing drug permeability in the cornea].

    Science.gov (United States)

    Masteiková, R; Chalupová, Z; Savickiene, N

    2004-03-01

    Most eye diseases are treated by topical administration of ophthalmic preparations. Low ophthalmic bioavailability is due to a number of physiological and physicochemical factors. The main obstacle to the penetration of active ingredients to the eye is the layered character of the cornea. Formulation of ophthalmic preparations enabling easier penetration of this biological barrier thus ranks among the most effective ways of improving bioavailability. Penetrability of the cornea can be increased by the following methods: a) adjustment of the actual acidity in such a way that pH of the preparation makes it possible to produce the optimal portion of non-ionized particles; b) incorporation of absorption enhancers (non-ionic tensides, salts of bile acids, some antimicrobial substances, EDTA, cyclodextrins, etc.) into the composition of the preparation, and c) production of prodrugs or ionic pairs.

  14. Remote Access: A Vision for Mobile Medical Devices

    Directory of Open Access Journals (Sweden)

    Herbert Ernst

    2005-11-01

    Full Text Available During the Symposium for Remote Engineering and Virtual Instrumentation held at Brasov in early July 2005 an outlook was presented regarding the future potential of remote engineering for mobile medical devices. It is the intention of this article to recapitulate the content of the initiated discussions and to stimulate work in this complex and until now largely neglected field of application.

  15. How does the knowledge environment shape procurement practices for orthopaedic medical devices in Mexico?

    Science.gov (United States)

    Lingg, Myriam; Wyss, Kaspar; Durán-Arenas, Luis

    2016-07-08

    In organisational theory there is an assumption that knowledge is used effectively in healthcare systems that perform well. Actors in healthcare systems focus on managing knowledge of clinical processes like, for example, clinical decision-making to improve patient care. We know little about connecting that knowledge to administrative processes like high-risk medical device procurement. We analysed knowledge-related factors that influence procurement and clinical procedures for orthopaedic medical devices in Mexico. We based our qualitative study on 48 semi-structured interviews with various stakeholders in Mexico: orthopaedic specialists, government officials, and social security system managers or administrators. We took a knowledge-management related perspective (i) to analyse factors of managing knowledge of clinical procedures, (ii) to assess the role of this knowledge and in relation to procurement of orthopaedic medical devices, and (iii) to determine how to improve the situation. The results of this study are primarily relevant for Mexico but may also give impulsion to other health systems with highly standardized procurement practices. We found that knowledge of clinical procedures in orthopaedics is generated inconsistently and not always efficiently managed. Its support for procuring orthopaedic medical devices is insufficient. Identified deficiencies: leaders who lack guidance and direction and thus use knowledge poorly; failure to share knowledge; insufficiently defined formal structures and processes for collecting information and making it available to actors of health system; lack of strategies to benefit from synergies created by information and knowledge exchange. Many factors are related directly or indirectly to technological aspects, which are insufficiently developed. The content of this manuscript is novel as it analyses knowledge-related factors that influence procurement of orthopaedic medical devices in Mexico. Based on our results we

  16. Post-market clinical research conducted by medical device manufacturers: a cross-sectional survey

    Directory of Open Access Journals (Sweden)

    Ross JS

    2015-05-01

    Full Text Available Joseph S Ross, Katrina L Blount, Jessica D Ritchie, Beth Hodshon, Harlan M Krumholz Center for Outcomes Research and Evaluation, Yale-New Haven Hospital, New Haven, CT, USA Background: In the US, once a medical device is made available for use, several requirements have been established by the US Food and Drug Administration (FDA to ensure ongoing post-market surveillance of device safety and effectiveness. Our objective was to determine how commonly medical device manufacturers initiate post-market clinical studies or augment FDA post-market surveillance requirements for higher-risk devices that are most often approved via the FDA's pre-market approval (PMA pathway. Methods and results: We conducted a cross-sectional survey of 47 manufacturers with operations in California, Minnesota, and Massachusetts who market devices approved via the PMA pathway. Among 22 respondents (response rate =47%, nearly all self-reported conducting post-market clinical research studies, commonly between 1 and 5; only 1 respondent reported never conducting post-market clinical research studies. While manufacturers most often engaged in these studies to satisfy FDA requirements, other reasons were reported, including performance monitoring and surveillance and market acceptance initiatives. Risks of conducting and not conducting post-market clinical research studies were described through open-ended response to questions. Conclusion: Medical device manufacturers commonly initiate post-market clinical studies at the request of the FDA. Clinical data from these studies should be integrated into national post-market surveillance initiatives. Keywords: FDA, PMA pathway, post-market surveillance

  17. 21 CFR 801.125 - Medical devices for use in teaching, law enforcement, research, and analysis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices for use in teaching, law enforcement, research, and analysis. 801.125 Section 801.125 Food and Drugs FOOD AND DRUG ADMINISTRATION... Directions for Use § 801.125 Medical devices for use in teaching, law enforcement, research, and analysis. A...

  18. [Radiotherapy and implantable medical device: example of infusion pumps].

    Science.gov (United States)

    Abrous-Anane, S; Benhassine, S; Lopez, S; Cristina, K; Mazeron, J-J

    2013-12-01

    Indication for radiotherapy is often questioned for patients equipped with implantable medical devices like infusion pumps as the radiation tolerance is poor or not known. We report here on the case of a patient who we treated with pelvic radiotherapy for cervical cancer and who had an infusion pump in iliac fossa. We conducted a series of tests on five identical pumps that insured that the treatment protocol is harmless to the implanted device. Copyright © 2013 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  19. A prospective window into medical device-related pressure ulcers in intensive care.

    Science.gov (United States)

    Coyer, Fiona M; Stotts, Nancy A; Blackman, Virginia Schmied

    2014-12-01

    The aim of this study was to determine the prevalence, severity, location, aetiology, treatment and healing of medical device-related pressure ulcers (PUs) in intensive care patients for up to 7 days. A prospective repeated measures study design was used. Patients in six intensive care units of two major medical centres, one each in Australia and the USA, were screened 1 day per month for 6 months. Those with device-related ulcers were followed daily for up to 7 days. The outcome measures were device-related ulcer prevalence, pain, infection, treatment and healing. Fifteen of 483 patients had device-related ulcers and 9 of 15 with 11 ulcers were followed beyond screening. Their mean age was 60·5 years, and most were men, overweight and at increased risk of PU. Endotracheal (ET) and nasogastric (NG) tubes were the cause of most device-related ulcers. Repositioning was the most frequent treatment. Four of 11 ulcers healed within the 7-day observation period. In conclusion, device-related ulcer prevalence was 3·1%, similar to that reported in the limited literature available, indicating an ongoing problem. Systematic assessment and repositioning of devices are the mainstays of care. We recommend continued prevalence determination and that nurses remain vigilant to prevent device-related ulcers, especially in patients with NG and ET tubes. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  20. On-line integration of computer controlled diagnostic devices and medical information systems in undergraduate medical physics education for physicians.

    Science.gov (United States)

    Hanus, Josef; Nosek, Tomas; Zahora, Jiri; Bezrouk, Ales; Masin, Vladimir

    2013-01-01

    We designed and evaluated an innovative computer-aided-learning environment based on the on-line integration of computer controlled medical diagnostic devices and a medical information system for use in the preclinical medical physics education of medical students. Our learning system simulates the actual clinical environment in a hospital or primary care unit. It uses a commercial medical information system for on-line storage and processing of clinical type data acquired during physics laboratory classes. Every student adopts two roles, the role of 'patient' and the role of 'physician'. As a 'physician' the student operates the medical devices to clinically assess 'patient' colleagues and records all results in an electronic 'patient' record. We also introduced an innovative approach to the use of supportive education materials, based on the methods of adaptive e-learning. A survey of student feedback is included and statistically evaluated. The results from the student feedback confirm the positive response of the latter to this novel implementation of medical physics and informatics in preclinical education. This approach not only significantly improves learning of medical physics and informatics skills but has the added advantage that it facilitates students' transition from preclinical to clinical subjects. Copyright © 2011 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  1. Access to the ophthalmic artery by retrograde approach through the posterior communicating artery for intra-arterial chemotherapy of retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Chi-Tuan; Blanc, Raphael; Pistocchi, Silvia; Bartolini, Bruno; Piotin, Michel [Fondation Rothschild Hospital, Department of Interventional Neuroradiology, Paris (France); Lumbroso-Le Rouic, Livia [Institut Curie, Department of Ocular Oncology, Paris (France)

    2012-08-15

    Intra-arterial infusion of chemotherapy into the ophthalmic artery for treatment of retinoblastoma has been realized after catheterization of the internal carotid and temporary balloon occlusion beyond the orifice of the ophthalmic artery, or more recently after superselective canulation of the ophthalmic artery by a microcatheter. The superselective catheterization of the ophthalmic artery could be cumbersome because of the implantation of the ostium on the carotid siphon or because of the tortuosity of the carotid siphon. We report our experience of using a retrograde approach through the posterior communicating artery that allows a more direct angle of access to the origin of the ophthalmic artery. (orig.)

  2. Innovative medical devices and hospital decision making: a study comparing the views of hospital pharmacists and physicians.

    Science.gov (United States)

    Billaux, Mathilde; Borget, Isabelle; Prognon, Patrice; Pineau, Judith; Martelli, Nicolas

    2016-06-01

    Objectives Many university hospitals have developed local health technology assessment processes to guide informed decisions about new medical devices. However, little is known about stakeholders' perceptions and assessment of innovative devices. Herein, we investigated the perceptions regarding innovative medical devices of their chief users (physicians and surgeons), as well as those of hospital pharmacists, because they are responsible for the purchase and management of sterile medical devices. We noted the evaluation criteria used to assess and select new medical devices and suggestions for improving local health technology assessment processes indicated by the interviewees. Methods We randomly selected 18 physicians and surgeons (nine each) and 18 hospital pharmacists from 18 French university hospitals. Semistructured interviews were conducted between October 2012 and August 2013. Responses were coded separately by two researchers. Results Physicians and surgeons frequently described innovative medical devices as 'new', 'safe' and 'effective', whereas hospital pharmacists focused more on economic considerations and considered real innovative devices to be those for which no equivalent could be found on the market. No significant difference in evaluation criteria was found between these groups of professionals. Finally, hospital pharmacists considered the management of conflicts of interests in local health technology assessment processes to be an issue, whereas physicians and surgeons did not. Conclusions The present study highlights differences in perceptions related to professional affiliation. The findings suggest several ways in which current practices for local health technology assessment in French university hospitals could be improved and studied. What is known about the topic? Hospitals are faced with ever-growing demands for innovative and costly medical devices. To help hospital management deal with technology acquisition issues, hospital

  3. Long-term results of treatment with diquafosol ophthalmic solution for aqueous-deficient dry eye.

    Science.gov (United States)

    Koh, Shizuka; Ikeda, Chikako; Takai, Yoshihiro; Watanabe, Hitoshi; Maeda, Naoyuki; Nishida, Kohji

    2013-09-01

    To evaluate the preliminary long-term efficacy of diquafosol ophthalmic solution for aqueous-deficient dry eye. Fifteen patients with mild-to-moderate aqueous-deficient dry eye were enrolled. After a washout period, the patients were treated with 3 % diquafosol ophthalmic solution for 6 months. We assessed 12 subjective dry eye symptoms, corneal and conjunctival staining with fluorescein, tear film break-up time (BUT), lower tear meniscus height measured with anterior-segment optical coherence tomography, Schirmer's testing, and adverse reactions at baseline and 1, 3, and 6 months after the start of treatment. Treatment with diquafosol ophthalmic solution significantly improved dry eye symptoms, corneal staining, BUT, and tear meniscus height at 1 month and maintained the effectiveness for 6 months. Conjunctival staining significantly improved 3 and 6 months after treatment. No significant adverse reactions developed. Prolonged use of diquafosol ophthalmic solution for 6 months produced significant improvement both subjectively (dry eye symptom score) and objectively (ocular staining score and tear function tests) for aqueous-deficient dry eye.

  4. Utilizing national and international registries to enhance pre-market medical device regulatory evaluation.

    Science.gov (United States)

    Yue, Lilly Q; Campbell, Gregory; Lu, Nelson; Xu, Yunling; Zuckerman, Bram

    2016-01-01

    Regulatory decisions are made based on the assessment of risk and benefit of medical devices at the time of pre-market approval and subsequently, when post-market risk-benefit balance needs reevaluation. Such assessments depend on scientific evidence obtained from pre-market studies, post-approval studies, post-market surveillance studies, patient perspective information, as well as other real world data such as national and international registries. Such registries provide real world evidence and are playing a more and more important role in enhancing the safety and effectiveness evaluation of medical devices. While these registries provide large quantities of data reflecting real world practice and can potentially reduce the cost of clinical trials, challenges arise concerning (1) data quality adequate for regulatory decision-making, (2) bias introduced at every stage and aspect of study, (3) scientific validity of study designs, and (4) reliability and interpretability of study results. This article will discuss related statistical and regulatory challenges and opportunities with examples encountered in medical device regulatory reviews.

  5. Biofilm eradication and prevention: a pharmaceutical approach to medical device infections

    National Research Council Canada - National Science Library

    Shunmugaperumal, Tamilvanan

    2010-01-01

    "Biofilm Eradication and Preventions presents the basics of biofilm formation on medical devices, diseases related to this formation, and approaches pharmaceutical researchers need to take to limit this problem...

  6. Commercial viability of medical devices using Headroom and return on investment calculation

    NARCIS (Netherlands)

    Markiewicz, Katarzyna; van Til, Janine Astrid; Steuten, Lotte Maria Gertruda; IJzerman, Maarten Joost

    2016-01-01

    The market success of a medical product depends on its commercial viability, yet this may be hard to predict during the development process of medical devices. This paper aims to determine if applying the Headroom method combined with return on investment (ROI) analysis allows for estimation of the

  7. Medical students perception of undergraduate ophthalmology training in Nnamdi Azikiwe University Nnewi Campus.

    Science.gov (United States)

    Onyekwe, L O; Nwosu, S N N

    2006-12-01

    To determine the perception and aspiration of medical students towards ophthalmology. Information for the study was obtained through forced-choice questionnaire set to 102 medical students in 2000/2001 graduating class in Nnamdi Azikiwe University. One hundred questionnaires were completed. As a specialty of choice ophthalmology ranked fourth {16.0%} as a first choice; second {21.0%} as a second choice and first {26.0%} as a third choice. Ninety-five of respondents found ophthalmology training useful. This cohort of medical students considered ophthalmic training in this institution essential and adequate. Undergraduate ophthalmic course should ensure an understanding of the basic principles of ophthalmology and should be designed to motivate the interest and confidence of the medical students in the specialty. Training period should be at least 4 weeks. With appropriate training ophthalmology can attract reasonable interest as a choice for specification.

  8. 76 FR 34845 - Medical Devices; Ear, Nose, and Throat Devices; Classification of the Wireless Air-Conduction...

    Science.gov (United States)

    2011-06-15

    ... control by other users with a similar medical device. Exposure to non-ionizing radiation Wireless... relating to EMC and wireless technology and human exposure to non-ionizing radiation. Therefore, on March... electro magnetic compatibility (EMC) and safety of exposure to non-ionizing radiation; (2) Design...

  9. Closed-loop approach for situation awareness of medical devices and operating room infrastructure

    Directory of Open Access Journals (Sweden)

    Rockstroh Max

    2015-09-01

    Full Text Available In recent years, approaches for information and control integration in the digital operating room have emerged. A major step towards an intelligent operating room and a cooperative technical environment would be autonomous adaptation of medical devices and systems to the surgical workflow. The OR staff should be freed from information seeking and maintenance tasks. We propose a closed-loop concept integrating workflow monitoring, processing and (semi-automatic interaction to bridge the gap between OR integration of medical devices and workflow-related information management.

  10. Mobile Devices, Learning and Clinical Workplaces: Medical Student Use of Smartphones in Parisian Hospitals

    Science.gov (United States)

    Phelps, Megan; Scott, Karen M.; Chauffeté-Manillier, Martine; Lenne, Frédéric; Le Jeunne, Claire

    2017-01-01

    Mobile devices are ubiquitous worldwide, including in hospitals. "Just in time" learning provided by these devices is important for students. We investigated current use of, and learning with, smartphones and other mobile devices by medical students in Parisian hospitals. A survey with quantitative and qualitative items previously used…

  11. 21 CFR 886.1435 - Maxwell spot.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Maxwell spot. 886.1435 Section 886.1435 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1435 Maxwell spot. (a) Identification. A Maxwell spot is an AC...

  12. Microbiological Load Of Ethylene Oxide Sterilized Medical Devices And Its Elimination By Cobalt 60 Source

    International Nuclear Information System (INIS)

    Bashir, R.; Afroze, B.; Zulfiqar, H. F.; Saleem, R.; Saleem, F.; Aslam, F.; Naz, S.

    2016-01-01

    Objective: To determine the residing microbial flora of ethylene oxide (EtO) sterilized medical devices and optimization of safe dose of gamma radiation (Cobalt 60 source) for the complete elimination of microbial load. Study Design: Experimental study. Place and Duration of Study: Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan from September 2014 to June 2015. Methodology: Thirty-six samples of EtO sterilized medical devices of same batch of three different companies were collected for this study. Isolation and enumeration of microbes were done by using different selective and differential media. Gram staining and biochemically characterization by API 20 (Bio Merieux, France) kit was done for identification of the microorganisms. The medical devices having high microbial load were sent to Pakistan Radiation Services (PARAS) for gamma irradiations at 3 different selected doses (20 KGy, 25 KGy, and 30 KGy). Result: Different types of Gram positive bacteria (Staphylococcus epidermidis, Staphylococcus aureus and Bacillus subtilis) were isolated from the EtO sterilized samples. Gram negative bacteria and fungi were not detected on these medical devices. Gamma irradiations Result showed that 30 KGy was optimized dose for complete elimination of microbial flora on endotracheal, Nelaton, and tracheostomy tubes. Conclusion: Gamma radiations (Co 60 source) effectively decontaminate the microbial flora on the equipment previously sterilized by the ethylene oxide gas; and 30 KGy is the optimized dose for all these medical devices. (author)

  13. Hydroxychloroquine screening practice patterns within a large multispecialty ophthalmic practice.

    Science.gov (United States)

    Au, Adrian; Parikh, Vishal; Modi, Yasha S; Ehlers, Justis P; Schachat, Andrew P; Singh, Rishi P

    2015-09-01

    To determine provider compliance with hydroxychloroquine screening following the revised recommendations published in 2011 by the American Academy of Ophthalmology. Evaluation of adherence to a screening protocol. Subjects were identified with hydroxychloroquine as a medication by electronic query at a large multispecialty ophthalmic practice. Patients were excluded if patients: (1) were screened by an outside physician; (2) lacked recorded height, weight, start date, or dosing; or (3) took hydroxychloroquine for malaria prophylaxis. Screening tests were stratified by ophthalmic subspecialty. Guidelines define proper screening as 1 subjective test-Humphrey visual field (HVF), and 1 objective test-spectral-domain optical coherence tomography (SD OCT), fundus autofluorescence (FAF), or multifocal electroretinography (mfERG). Adherence to guidelines was determined by categorizing practices as: (1) "appropriate"-consistent with guidelines; (2) "underscreened"-insufficient testing; or (3) "inappropriate"-no testing. The study comprised 756 patients with a mean age of 56 years undergoing 1294 screening visits. Twenty-one patients received initial screenings outside the institution. Most common screening tests employed included SD OCT (56.6%), 10-2 HVF (55.0%), and Amsler grid (40.0%). Of the 735 initial screenings, 341 (46.4%) were appropriately screened, 204 (27.8%) underscreened, and 190 (25.9%) inappropriately screened. Of those who presented solely for screening (560), 307 (54.8%) were appropriately screened, 144 (25.7%) underscreened, and 109 (19.5%) inappropriately screened. Of patients presenting for hydroxychloroquine screening, 54.8% of patients received appropriate evaluation, indicating lack of adherence to guidelines. Overall, SD OCT and 10-2 HVF were the preferred screening modalities, with FAF and mfERG less frequently ordered. Copyright © 2015 Elsevier Inc. All rights reserved.

  14. Development and Effects of FTY720 Ophthalmic Solution on Corneal Allograft Survival

    OpenAIRE

    Zhaochuan Liu; Haotian Lin; Chulong Huang; Wan Chen; Wu Xiang; Yu Geng; Weirong Chen

    2015-01-01

    Fingolimod (FTY720), a novel class of sphingosine 1-phosphate receptor modulators, has received special interest among ophthalmologists, particularly given that oral administration of FTY720 has proven to effectively treat corneal graft rejection in animal models. However, no studies have examined the performance of FTY720 as an ophthalmic solution in reducing corneal rejection in high-risk corneal rejection models, and the stability and ocular irritation profile of FTY720 ophthalmic solution...

  15. Characterization of Bacterial Etiologic Agents of Biofilm Formation in Medical Devices in Critical Care Setup

    Directory of Open Access Journals (Sweden)

    Sangita Revdiwala

    2012-01-01

    Full Text Available Background. Biofilms contaminate catheters, ventilators, and medical implants; they act as a source of disease for humans, animals, and plants. Aim. Critical care units of any healthcare institute follow various interventional strategies with use of medical devices for the management of critical cases. Bacteria contaminate medical devices and form biofilms. Material and Methods. The study was carried out on 100 positive bacteriological cultures of medical devices which were inserted in hospitalized patients. The bacterial isolates were processed as per microtitre plate. All the isolates were subjected to antibiotic susceptibility testing by VITEK 2 compact automated systems. Results. Out of the total 100 bacterial isolates tested, 88 of them were biofilm formers. A 16–20-hour incubation period was found to be optimum for biofilm development. 85% isolates were multidrug resistants and different mechanisms of bacterial drug resistance like ESBL, carbapenemase, and MRSA were found among isolates. Conclusion. Availability of nutrition in the form of glucose enhances the biofilm formation by bacteria. Time and availability of glucose are important factors for assessment of biofilm progress. It is an alarm for those who are associated with invasive procedures and indwelling medical devices especially in patients with low immunity.

  16. Observation on the availability and tolerance of 0.1% bromfenac sodium hydrate ophthalmic solution in the partial substitution of glucocorticoid after LASEK

    Directory of Open Access Journals (Sweden)

    Zhi-Hui Deng

    2015-12-01

    Full Text Available AIM:To observe the availability and tolerance of 0.1% bromfenac sodium hydrate ophthalmic solution in the partial substitution of glucocorticoid after laser subepithelial keratomileusis(LASEK. METHODS:Totally 180 patients(180 eyesreceived LASEK were selected and divided into study group and control group according to different medications. The study group adopted 0.1% bromfenac sodium hydrate ophthalmic solution combined with glucocorticoid; the control group adopted glucocorticoid. The changes of visual acuity and intraocular pressure(IOPof two groups were recorded before and after surgery and the occurrence of diffuse larnellar kerafitis(DLKafter surgery were observed. RESULTS:After 1mo of surgery, visual acuity of study group was 1.25±0.22 while that of control group was 0.97±0.23(PP>0.05. After 1 and 3mo of surgery, IOP of study group was 12.29±2.71 and 12.67±2.33mmHg while that of control group was 14.26±2.65 and 14.56±2.61mmHg, the difference was statistically significant(PP>0.05. In terms of tolerance, the control group had 4 cases(4 eyestaking the IOP-lowering medication. The study group had no uncomfortable cases. The DLK level of the study group at 0, 1, 2 was 93.33%, 6.67%, 0%, respectively and those in control group was 75.56%, 17.78% and 6.67%, respectively, and the differences were significant(PCONCLUSION:0.1% bromfenac sodium hydrate ophthalmic solution can efficiently stabilize the patient's IOP after LASEK. The patient has a better visual acuity, visual function and fewer complications. The tolerance is also favorable. It is worthy of promotion.

  17. Medical and welfare device session. Toward medical treatment and welfare of tomorrow; Iryo fukushi kiki session. Ashita no iryo fukushi ni mukete

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-09-01

    This paper is the material distributed in the medical and welfare device session held under the auspices of NEDO in September 2000. Diversification of needs in the medical and welfare areas and handling of age advancement are the growing issue. NEDO is putting efforts toward enhancement of quality of life (QOL) and realization of the nation with great life by providing high-quality and high-efficiency medical and welfare services. The NEDO's efforts cover the areas of treating adult diseases such as cancers and cardiac diseases whose seriousness is growing, early diagnoses of diseases, medical treatment with low invasion, elderly people helping, reduction of helpers' burden, reduction of handicaps to elderly people and mentally and physically handicapped persons, and assistance to participation in the society. To achieve these goals, NEDO is implementing the following four projects: research and development of medical and welfare device technologies, researches of medical science and engineering collaboration type, and promotion of developing welfare techno-systems and practical application of welfare appliances. Developments are being made toward practical application of medical and welfare devices with excellent safety and convenience, of low cost and high performance. The session gave the keynote addresses related to medical treatment and prevention of brain diseases; brain, the universe and MRI (the world of mind as seen in images), and high-tech medical treatments to protect brain (challenge to brain that starts now). (NEDO)

  18. Analysis of liquid medication dose errors made by patients and caregivers using alternative measuring devices.

    Science.gov (United States)

    Ryu, Gyeong Suk; Lee, Yu Jeung

    2012-01-01

    Patients use several types of devices to measure liquid medication. Using a criterion ranging from a 10% to 40% variation from a target 5 mL for a teaspoon dose, previous studies have found that a considerable proportion of patients or caregivers make errors when dosing liquid medication with measuring devices. To determine the rate and magnitude of liquid medication dose errors that occur with patient/caregiver use of various measuring devices in a community pharmacy. Liquid medication measurements by patients or caregivers were observed in a convenience sample of community pharmacy patrons in Korea during a 2-week period in March 2011. Participants included all patients or caregivers (N = 300) who came to the pharmacy to buy over-the-counter liquid medication or to have a liquid medication prescription filled during the study period. The participants were instructed by an investigator who was also a pharmacist to select their preferred measuring devices from 6 alternatives (etched-calibration dosing cup, printed-calibration dosing cup, dosing spoon, syringe, dispensing bottle, or spoon with a bottle adapter) and measure a 5 mL dose of Coben (chlorpheniramine maleate/phenylephrine HCl, Daewoo Pharm. Co., Ltd) syrup using the device of their choice. The investigator used an ISOLAB graduated cylinder (Germany, blue grad, 10 mL) to measure the amount of syrup dispensed by the study participants. Participant characteristics were recorded including gender, age, education level, and relationship to the person for whom the medication was intended. Of the 300 participants, 257 (85.7%) were female; 286 (95.3%) had at least a high school education; and 282 (94.0%) were caregivers (parent or grandparent) for the patient. The mean (SD) measured dose was 4.949 (0.378) mL for the 300 participants. In analysis of variance of the 6 measuring devices, the greatest difference from the 5 mL target was a mean 5.552 mL for 17 subjects who used the regular (etched) dosing cup and 4

  19. Biomaterials in medical devices: an interview with Jörg Vienken of Fresenius Medical Care, Germany.

    Science.gov (United States)

    Vienken, Jörg

    2012-06-01

    Biomaterial and biopolymer research have significant impact on the development as well as application of biotechnology. Biotechnology Journal recently attended the "Nanomaterials for Biomedical Technologies 2012" conference. We were privileged to have the opportunity to ask Prof. Dr. Jörg Vienken, VP of BioSciences at Fresenius Medical Care, a few questions relating to medical devices, the importance of publishing for industry, and also his advice for young scientists/engineers looking for a career in industry. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Medical applications of superconducting quantum interference devices

    International Nuclear Information System (INIS)

    Uehara, Gen

    2011-01-01

    SQUIDs (Superconducting Quantum Interference Devices) are applied to clinical areas and basic medical science fields because of their potential for measuring a minute magnetic signal from the human body. Magnetoencephalography, one of their applications, is used for the functional mapping of the brain cortex before surgery and the localization of focus of epilepsy. Recently, their applications to the early-stage detection of dementia and the localization of brain ischemia are suggested. Another application of SQUIDs is magnetospinography, which detects the conduction block in spinal cord signal propagation. (author)

  1. Design controls for the medical device industry

    CERN Document Server

    Teixeira, Marie B

    2013-01-01

    The second edition of a bestseller, Design Controls for the Medical Device Industry provides a comprehensive review of the latest design control requirements, as well as proven tools and techniques to ensure your company's design control program evolves in accordance with current industry practice. The text assists in the development of an effective design control program that not only satisfies the US FDA Quality System Regulation (QSR) and ISO 9001 and 13485 standards, but also meets today's third-party auditor/investigator expectations and saves you valuable time and money.The author's cont

  2. 76 FR 18227 - Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of...

    Science.gov (United States)

    2011-04-01

    ...] Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of Meeting... comment period for the notice announcing a meeting of the Molecular and Clinical Genetics Panel (the panel... Clinical Genetics Panel of the Medical Devices Advisory Committee, and the opening of a public docket to...

  3. High-risk medical devices, children and the FDA: regulatory challenges facing pediatric mechanical circulatory support devices.

    Science.gov (United States)

    Almond, Christopher S D; Chen, Eric A; Berman, Michael R; Less, Joanne R; Baldwin, J Timothy; Linde-Feucht, Sarah R; Hoke, Tracey R; Pearson, Gail D; Jenkins, Kathy; Duncan, Brian W; Zuckerman, Bram D

    2007-01-01

    Pediatric mechanical circulatory support is a critical unmet need in the United States. Infant- and child-sized ventricular assist devices are currently being developed largely through federal contracts and grants through the National Heart, Lung, and Blood Institute (NHLBI). Human testing and marketing of high-risk devices for children raises epidemiologic and regulatory issues that will need to be addressed. Leaders from the US Food and Drug Administration (FDA), NHLBI, academic pediatric community, and industry convened in January 2006 for the first FDA Workshop on the Regulatory Process for Pediatric Mechanical Circulatory Support Devices. The purpose was to provide the pediatric community with an overview of the federal regulatory process for high-risk medical devices and to review the challenges specific to the development and regulation of pediatric mechanical circulatory support devices. Pediatric mechanical circulatory support present significant epidemiologic, logistic, and financial challenges to industry, federal regulators, and the pediatric community. Early interactions with the FDA, shared appreciation of challenges, and careful planning will be critical to avoid unnecessary delays in making potentially life-saving devices available for children. Collaborative efforts to address these challenges are warranted.

  4. Software-Related Recalls of Health Information Technology and Other Medical Devices: Implications for FDA Regulation of Digital Health.

    Science.gov (United States)

    Ronquillo, Jay G; Zuckerman, Diana M

    2017-09-01

    Policy Points: Medical software has become an increasingly critical component of health care, yet the regulation of these devices is inconsistent and controversial. No studies of medical devices and software assess the impact on patient safety of the FDA's current regulatory safeguards and new legislative changes to those standards. Our analysis quantifies the impact of software problems in regulated medical devices and indicates that current regulations are necessary but not sufficient for ensuring patient safety by identifying and eliminating dangerous defects in software currently on the market. New legislative changes will further deregulate health IT, reducing safeguards that facilitate the reporting and timely recall of flawed medical software that could harm patients. Medical software has become an increasingly critical component of health care, yet the regulatory landscape for digital health is inconsistent and controversial. To understand which policies might best protect patients, we examined the impact of the US Food and Drug Administration's (FDA's) regulatory safeguards on software-related technologies in recent years and the implications for newly passed legislative changes in regulatory policy. Using FDA databases, we identified all medical devices that were recalled from 2011 through 2015 primarily because of software defects. We counted all software-related recalls for each FDA risk category and evaluated each high-risk and moderate-risk recall of electronic medical records to determine the manufacturer, device classification, submission type, number of units, and product details. A total of 627 software devices (1.4 million units) were subject to recalls, with 12 of these devices (190,596 units) subject to the highest-risk recalls. Eleven of the devices recalled as high risk had entered the market through the FDA review process that does not require evidence of safety or effectiveness, and one device was completely exempt from regulatory review

  5. Real-time volume rendering of digital medical images on an iOS device

    Science.gov (United States)

    Noon, Christian; Holub, Joseph; Winer, Eliot

    2013-03-01

    Performing high quality 3D visualizations on mobile devices, while tantalizingly close in many areas, is still a quite difficult task. This is especially true for 3D volume rendering of digital medical images. Allowing this would empower medical personnel a powerful tool to diagnose and treat patients and train the next generation of physicians. This research focuses on performing real time volume rendering of digital medical images on iOS devices using custom developed GPU shaders for orthogonal texture slicing. An interactive volume renderer was designed and developed with several new features including dynamic modification of render resolutions, an incremental render loop, a shader-based clipping algorithm to support OpenGL ES 2.0, and an internal backface culling algorithm for properly sorting rendered geometry with alpha blending. The application was developed using several application programming interfaces (APIs) such as OpenSceneGraph (OSG) as the primary graphics renderer coupled with iOS Cocoa Touch for user interaction, and DCMTK for DICOM I/O. The developed application rendered volume datasets over 450 slices up to 50-60 frames per second, depending on the specific model of the iOS device. All rendering is done locally on the device so no Internet connection is required.

  6. 47 CFR 95.1119 - Specific requirements for wireless medical telemetry devices operating in the 608-614 MHz band.

    Science.gov (United States)

    2010-10-01

    ... devices operating in the 608-614 MHz band. For a wireless medical telemetry device operating within the... 47 Telecommunication 5 2010-10-01 2010-10-01 false Specific requirements for wireless medical telemetry devices operating in the 608-614 MHz band. 95.1119 Section 95.1119 Telecommunication FEDERAL...

  7. Comparison of the effects of ophthalmic solutions on human corneal epithelial cells using fluorescent dyes.

    Science.gov (United States)

    Xu, Manlong; Sivak, Jacob G; McCanna, David J

    2013-11-01

    To investigate the effect of differently preserved ophthalmic solutions on the viability and barrier function of human corneal epithelial cells (HCEC) using fluorescent dyes. HCEC monolayers were exposed to the ophthalmic solutions containing benzalkonium chloride (BAK), edetate disodium, polyquad, stabilized oxychloro complex (Purite), sodium perborate, or sorbic acid for 5 min, 15 min, and 1 h. At 24 h after exposure, the cultures were assessed for metabolic activity using alamarBlue. The enzyme activity, membrane integrity, and apoptosis were evaluated using confocal microscopy. Barrier function was assessed using sodium fluorescein. The metabolic assay showed that the BAK-preserved ophthalmic solutions significantly reduced cell viability after a 5-min exposure compared to the phosphate buffered saline treated control (POphthalmic solutions with new preservatives had varying time-dependent adverse effects on cell viability, and the preservative-free solution had the least effect on HCEC. Sodium fluorescein permeability showed that HCEC monolayers treated with BAK-preserved solutions were more permeable to sodium fluorescein than those treated by the other ophthalmic solutions (Psolutions had greater adverse effects on metabolic activity, enzyme activity, membrane integrity, cell viability, and barrier function than the solutions that were not preserved with BAK. Our study suggests that BAK-free especially, preservative-free ophthalmic solutions are safer alternatives to BAK-preserved ones.

  8. Determination of feasibility and utility of microscope-integrated optical coherence tomography during ophthalmic surgery: the DISCOVER Study RESCAN Results.

    Science.gov (United States)

    Ehlers, Justis P; Goshe, Jeff; Dupps, William J; Kaiser, Peter K; Singh, Rishi P; Gans, Richard; Eisengart, Jonathan; Srivastava, Sunil K

    2015-10-01

    Optical coherence tomography (OCT) has transformed the clinical management of a myriad of ophthalmic conditions. Applying OCT to ophthalmic surgery may have implications for surgical decision making and patient outcomes. To assess the feasibility and effect on surgical decision making of a microscope-integrated intraoperative OCT (iOCT) system. Report highlighting the 1-year results (March 2014-February 2015) of the RESCAN 700 portion of the DISCOVER (Determination of Feasibility of Intraoperative Spectral Domain Microscope Combined/Integrated OCT Visualization During En Face Retinal and Ophthalmic Surgery) study, a single-site, multisurgeon, prospective consecutive case series regarding this investigational device. Participants included patients undergoing ophthalmic surgery. Data on clinical characteristics were collected, and iOCT was performed during surgical milestones, as directed by the operating surgeon. A surgeon questionnaire was issued to each surgeon and was completed after each case to evaluate the role of iOCT during surgery and its particular role in select surgical procedures. Percentage of cases with successful acquisition of iOCT (ie, feasibility). Percentage of cases in which iOCT altered surgical decision making (ie, utility). During year 1 of the DISCOVER study, a total of 227 eyes (91 anterior segment cases and 136 posterior segment cases) underwent imaging with the RESCAN 700 system. Successful imaging (eg, the ability to acquire an OCT image of the tissue of interest) was obtained for 224 of 227 eyes (99% [95% CI, 98%-100%]). During lamellar keratoplasty, the iOCT data provided information that altered the surgeon's decision making in 38% of the cases (eg, complete graft apposition when the surgeon believed there was interface fluid). In membrane peeling procedures, iOCT information was discordant with the surgeon's impression of membrane peel completeness in 19% of cases (eg, lack of residual membrane or presence of occult membrane), thus

  9. OpenICE medical device interoperability platform overview and requirement analysis.

    Science.gov (United States)

    Arney, David; Plourde, Jeffrey; Goldman, Julian M

    2018-02-23

    We give an overview of OpenICE, an open source implementation of the ASTM standard F2761 for the Integrated Clinical Environment (ICE) that leverages medical device interoperability, together with an analysis of the clinical and non-functional requirements and community process that inspired its design.

  10. Lessons learned: mobile device encryption in the academic medical center.

    Science.gov (United States)

    Kusche, Kristopher P

    2009-01-01

    The academic medical center is faced with the unique challenge of meeting the multi-faceted needs of both a modern healthcare organization and an academic institution, The need for security to protect patient information must be balanced by the academic freedoms expected in the college setting. The Albany Medical Center, consisting of the Albany Medical College and the Albany Medical Center Hospital, was challenged with implementing a solution that would preserve the availability, integrity and confidentiality of business, patient and research data stored on mobile devices. To solve this problem, Albany Medical Center implemented a mobile encryption suite across the enterprise. Such an implementation comes with complexities, from performance across multiple generations of computers and operating systems, to diversity of application use mode and end user adoption, all of which requires thoughtful policy and standards creation, understanding of regulations, and a willingness and ability to work through such diverse needs.

  11. 21 CFR 801.1 - Medical devices; name and place of business of manufacturer, packer or distributor.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical devices; name and place of business of manufacturer, packer or distributor. 801.1 Section 801.1 Food and Drugs FOOD AND DRUG ADMINISTRATION... § 801.1 Medical devices; name and place of business of manufacturer, packer or distributor. (a) The...

  12. The future of the pharmaceutical, biological and medical device industry

    Directory of Open Access Journals (Sweden)

    Burgess LJ

    2011-09-01

    Full Text Available Lesley J Burgess, Marli TerblancheTREAD Research/Cardiology Unit, Department of Internal Medicine, Tygerberg Hospital and University of Stellenbosch, Parow, South AfricaAbstract: Numerous factors contribute to the declining pharmaceutical industry on the one hand and the rapidly growing generic industry together with the growing importance of medical devices and biologicals on the other. It is clear that the pharmaceutical industry is going to undergo a change in the next decade in order to meet the current challenges facing it and ultimately sustain its profitability and growth. This paper aims to identify a number of fairly obvious trends that are likely to have a significant impact on the product development pipeline in the next decade. It is more than clear that the current production pipeline for pharmaceutical, biotechnology and medical device industries is no longer sustainable and that urgent interventions are required in order to maintain its current level of profitability.Keywords: pharmaceutical industry, personalized medicine, trends, generics, biotechnology

  13. Hydrophilic Polymer Embolism: Implications for Manufacturing, Regulation, and Postmarket Surveillance of Coated Intravascular Medical Devices.

    Science.gov (United States)

    Mehta, Rashi I; Mehta, Rupal I

    2018-03-19

    Hydrophilic polymers are ubiquitously applied as surface coatings on catheters and intravascular medical technologies. Recent clinical literature has heightened awareness on the complication of hydrophilic polymer embolism, the phenomenon wherein polymer coating layers separate from catheter and device surfaces, and may be affiliated with a range of unanticipated adverse reactions. Significant system barriers have limited and delayed reporting on this iatrogenic complication, the full effects of which remain underrecognized by healthcare providers and manufacturers of various branded devices. In 2015, the United States Food and Drug Administration acknowledged rising clinical concerns and stated that the agency would work with stakeholders to further evaluate gaps that exist in current national and international device standards for coated intravascular medical technologies. The present article reviews current knowledge on this complication as well as factors that played a role in delaying detection and dissemination of information and new knowledge once hazards and clinical risks were identified. Furthermore, organ-specific effects and adverse reaction patterns are summarized, along with implications for device manufacturing, safety assurance, and regulation. Qualitative and quantitative particulate testing are needed to optimize coated intravascular device technologies. Moreover, general enhanced processes for medical device surveillance are required for timely adverse event management and to ensure patient safety.

  14. Shortcomings of the industrial quality assurance of 106Ru ophthalmic plaques

    International Nuclear Information System (INIS)

    Kaulich, T.W.; Nuesslin, F.; Fluehs, D.; Haug, T.; Bamberg, M.

    2001-01-01

    Background: Beta emitting 106 Ru applicators manufactured by Bebig GmbH (Berlin, Germany) are widely used to treat intraocular tumors. The applicators are fixed to the bulbus and removed after several days. The following therapy relevant defects have been detected by an internal clinical acceptance test: risk of leakage and inconsistent dose-rate specifications by the manufacturer. In the meantime, components of the internal clinical acceptance test have been adopted successfully by the manufacturer of the 106 Ru ophthalmic plaques. Material and Method: 106 Ru ophthalmic plaques were tested with the following internal clinical acceptance tests: visual inspection, surface contamination, leakage, and dose-rate verification. The surface contamination test consists of a wet wipe test at moderate pressure. For the leakage test of the 106 Ru ophthalmic plaques a clinically relevant scenario was developed in which the contact of the applicator with human tissue is simulated. In the course of it the applicator is inserted into Ringer's solution for several days. The certified energy dose-rate statements of the manufacturer are examined with a 1 mm 3 plastic scintillator for consistency. (orig.) [de

  15. Value-based procurement of medical devices: Application to devices for mechanical thrombectomy in ischemic stroke.

    Science.gov (United States)

    Trippoli, Sabrina; Caccese, Erminia; Marinai, Claudio; Messori, Andrea

    2018-03-01

    In the acute ischemic stroke, endovascular devices have shown promising clinical results and are also likely to represent value for money, as several modeling studies have shown. Pharmacoeconomic evaluations in this field, however, have little impact on the procurement of these devices. The present study explored how complex pharmacoeconomic models that evaluate effectiveness and cost can be incorporated into the in-hospital procurement of thrombectomy devices. As regards clinical modeling, we extracted outcomes at three months from randomized trials conducted for four thrombectomy devices, and we projected long-term results using standard Markov modeling. In estimating QALYs, the same model was run for the four devices. As regards economic modeling, we firstly estimated for each device the net monetary benefit (NMB) per patient (threshold = $60,000 per QALY); then, we simulated a competitive tender across the four products by determining the tender-based score (on a 0-to-100 scale). Prices of individual devices were obtained from manufacturers. Extensive sensitivity testing was applied to our analyses. For the four devices (Solitaire, Trevo, Penumbra, Solumbra), QALYs were 1.86, 1.52, 1,79, 1.35, NMB was $101,824, $83,546, $101,923, $69,440, and tender-based scores were 99.70, 43.43, 100, 0, respectively. Sensitivity analysis confirmed findings from base-case. Our results indicate that, in the field of thrombectomy devices, incorporating the typical tools of cost-effectiveness into the processes of tenders and procurement is feasible. Bridging the methodology of cost-effectiveness with the every-day practice of in-hospital procurement can contribute to maximizing the health returns that are generated by in-hospital expenditures for medical devices. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Polymer coating embolism from intravascular medical devices - a clinical literature review.

    Science.gov (United States)

    Chopra, Amitabh M; Mehta, Monik; Bismuth, Jean; Shapiro, Maksim; Fishbein, Michael C; Bridges, Alina G; Vinters, Harry V

    Over the past three decades, lubricious (hydrophobic and/or hydrophilic) polymer-coated devices have been increasingly adopted by interventional physicians and vascular surgeons to access and treat a wider range of clinical presentations. Recent clinical literature highlights the presence of polymer coating emboli within the anatomy - a result of coating separation from an intravascular device - and associates it with a range of adverse clinical sequelae. The 2015 U.S. Food and Drug Administration safety communication titled "Lubricious Coating Separation from Intravascular Medical Devices" acknowledges these concerns and concludes that it will work with stakeholders to develop nonclinical test methodologies, establish performance criteria, and identify gaps in current national and international device standards for coating integrity performance. Despite this communication and multiple case reports from interventional physicians, pathologists, dermatologists and other involved physician specialties, polymer coating embolism remains clinically underrecognized. This article consolidates the available literature on polymer coating embolism (1986-2016) and highlights the following relevant information for the physician: (a) the history and elusive nature of polymer coating embolism; (b) potential incidence rates of this phenomenon; (c) reported histologic findings and clinical effects of polymer emboli in the anatomy; (d) the importance of the collaborative clinician-pathologist partnership to report polymer embolism findings; and (e) the importance to study particulate release from intravascular devices so as to further understand and potentially evolve coated interventional technologies. Preliminary research on coatings highlights the potential of using iterations of coatings on medical devices that attain the desired therapeutic result and mitigate or eliminate particulates altogether. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Fluid temperature at the corneal endothelium during phacoemulsification: comparison of an ophthalmic viscosurgical device and balanced salt solution using the finite element method.

    Science.gov (United States)

    Reepolmaha, Somporn; Limtrakarn, Wiroj; Uthaisang-Tanechpongtamb, Wanlaya; Dechaumphai, Pramote

    2010-01-01

    The purpose of this study was to estimate and compare the temperatures of two different anterior chamber solutions at the corneal endothelial level during phacoemulsification. An ophthalmic viscosurgical device (OVD) and balanced salt solution (BSS) were compared using the finite element method (FEM). The thermal properties of an OVD (IAL-F) and BSS were studied in an experimental setting. A computer-aided design model of ocular anatomy was created in two dimensions. The phaco needle was considered to be the only source of heat generation. Then, the FEM was used to demonstrate the transient temperature distribution in the two ocular models at 10, 20, 30, 40, 50 and 60 s. In these models, the anterior chamber was filled with IAL-F (IAL-F model) or BSS (BSS model). The heat generation rate of the phaco needle was 0.0004 cal/s/mm(2). The maximum corneal endothelial temperatures for the two models at 60 s were 52.67 and 41.57 degrees C, respectively. The experimental IAL-F model showed fewer changes in temperature for any given time and location. At larger distances from the heat source, less temperature variation was detected. Phacoemulsification is a potential heat-generating procedure performed between the delicate anterior chamber structures. During this procedure, IAL-F protects the endothelium against heat better than BSS. Copyright 2009 S. Karger AG, Basel.

  18. FDA (Food and Drug Administration) Compliance Program Guidance Manual (FY 88). Section 4. Medical and radiological devices

    International Nuclear Information System (INIS)

    1988-01-01

    The FDA Compliance Program Guidance Manual provides a system for issuing and filing program plans and instructions directed to Food and Drug Administration Field operations for project implementation. Section IV provides those chapters of the Compliance Program Guidance Manual which pertain to the areas of medical and radiological devices. Some of the areas of coverage include laser and sunlamp standards inspections, compliance testing of various radiation-emitting products such as television receivers and microwave ovens, emergency response planning and policy, premarket approval and device manufacturers inspections, device problem reporting, sterilization of devices, and consumer education programs on medical and radiological devices

  19. Pre-market approval and post-market direct-to-consumer advertising of medical devices in Australia: a case study of breast cancer screening and diagnostic devices.

    Science.gov (United States)

    Vreugdenburg, T D; Willis, C D; Mundy, L; Hiller, J E

    2013-01-01

    While research investigating direct-to-consumer advertising of therapeutic goods in Australia has historically focused on prescription medicines, recent action taken by regulators against companies promoting medical devices has placed the industry into the spotlight. Despite the need to effectively regulate direct-to-consumer advertising of medical devices due to its potential harms, inadequacies in the current regulatory system have been noted. Under the present system, devices with a questionable evidence base may enter the Australian marketplace without an evaluation of their effectiveness, and regulators are reliant on industry self-regulation and consumer complaints to draw attention to cases of advertising misconduct. Although some successes in the present system have been observed, we argue that the outlined inadequacies continue to enable the promotion of medical devices to consumers without thorough or sufficient examination of evidence. © 2011 The Authors; Internal Medicine Journal © 2011 Royal Australasian College of Physicians.

  20. 76 FR 6623 - Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Science.gov (United States)

    2011-02-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-N-0066] Molecular and Clinical Genetics Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY... public. Name of Committee: Molecular and Clinical Genetics Panel of the Medical Devices Advisory...

  1. Determination of Mycophenolic acid in the vitreous humor using the HPLC-ESI-MS/MS method: application of intraocular pharmacokinetics study in rabbit eyes with ophthalmic implantable device.

    Science.gov (United States)

    Martins Duarte Byrro, Ricardo; de Oliveira Fulgêncio, Gustavo; Rocha Chellini, Paula; da Silva Cunha, Armando; Pianetti, Gerson Antônio

    2013-10-01

    Mycophenolic acid (MPA) is an immunosuppressive agent widely used in the treatment of solid organ transplant rejection. The success of MPA in the treatment of inflammatory intraocular diseases has been reported in recent literature. The treatment of inflammatory eye diseases in the posterior chamber is a challenge due to the anatomy of the eye, which presents certain barriers to drug access. Thus, the bioavailability of drugs in the eye is quite low, and successful drug delivery may well represent a key limiting factor to attaining a successful therapeutic strategy. Ophthalmic controlled drug delivery offers the potential to enhance the efficacy of treatment for pathological conditions. Thus, a novel delivery system based on a biodegradable polymeric device, which can be implanted inside the eye and deliver MPA directly to the target, is being developed. Specific analytical methods to determine the use of effective drugs within the eye are needed to characterize this device. A liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) method for the quantitation of MPA in the vitreous humor of rabbits was developed and validated. The vitreous was collected from rabbits, extracted by a protein precipitation extraction procedure and then separated on a C18 column with a mobile phase comprised of 0.15% aqueous acetic acid and methanol (60:40, v/v). The calibration curve was constructed within the range of 3-10,000 ng/mL for MPA. The mean R.S.D. values for the intra-run and inter-run precision were 5.15% and 4.35%. The mean accuracy value was 100.16%. The validated method was successfully applied to determine the MPA concentration in the vitreous humor of rabbits treated with an ocular implantable device. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Pediatric ophthalmic indications for examination under anesthesia in ...

    African Journals Online (AJOL)

    Objective: To determine the ophthalmic indications and challenges for pediatric ocular examination under anesthesia (EUA). Methods: The surgical register and patients' records of children who underwent EUA between 1990 and 2007 were examined to document patients' bio data, diagnoses and details of procedures and ...

  3. A new human eye model for ophthalmic brachytherapy dosimetry

    International Nuclear Information System (INIS)

    Yoriyaz, H.; Sanchez, A.; Dos Santos, A.

    2005-01-01

    The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new model includes detailed description of internal structures that were not treated in previous works, allowing dose determination in different regions of the eye for a more adequate clinical analysis. Dose calculations were determined with the MCNP-4C Monte Carlo particle transport code running n parallel environment using PVM. The Amersham CKA4 ophthalmic applicator has been chosen and the depth dose distribution has been determined and compared to those provide by the manufacturer. The results have shown excellent agreement. Besides, absorbed dose values due to both 125 I seeds and 60 Co plaques were obtained for each one of the different structures which compose the eye model and can give relevant information in eventual clinical analyses. (authors)

  4. Challenges in the Assessment of Medical Devices: The MedtecHTA Project.

    Science.gov (United States)

    Tarricone, Rosanna; Torbica, Aleksandra; Drummond, Michael

    2017-02-01

    Assessing medical devices (MDs) raises challenges which require us to reflect on whether current methods are adequate. Major features of devices are: (i) device-operator interaction can generate learning curve effects; (ii) incremental nature of innovation needs to be addressed by careful identification of the alternatives for comparative and incremental cost-effectiveness analysis; and (iii) broader organizational impact in terms of training and infrastructure, coupled with dynamic pricing, requires a more flexible approach to costing. The objective of the MedtecHTA project was to investigate improvements in HTA methods to allow for more comprehensive evaluation of MDs. It consisted of several work packages concerning (i) the available evidence on the currently adopted approaches for regulation and HTA of medical devices; (ii) the geographical variation in access to MDs; (iii) the development of methodological frameworks for conducting comparative effectiveness research and economic evaluation of MDs; and (iv) the organizational impact of MDs. This introductory paper summarizes the main results of the project and draws out the main overarching themes. This supplement represents a comprehensive report of all the main findings of the MedtecHTA project, and it is intended to be the main source for researchers and policy makers wanting information on the project. © 2017 The Authors. Health Economics published by John Wiley & Sons, Ltd. © 2017 The Authors. Health Economics Published by John Wiley & Sons, Ltd.

  5. Interoperability of medical device information and the clinical applications: an HL7 RMIM based on the ISO/IEEE 11073 DIM.

    Science.gov (United States)

    Yuksel, Mustafa; Dogac, Asuman

    2011-07-01

    Medical devices are essential to the practice of modern healthcare services. Their benefits will increase if clinical software applications can seamlessly acquire the medical device data. The need to represent medical device observations in a format that can be consumable by clinical applications has already been recognized by the industry. Yet, the solutions proposed involve bilateral mappings from the ISO/IEEE 11073 Domain Information Model (DIM) to specific message or document standards. Considering that there are many different types of clinical applications such as the electronic health record and the personal health record systems, the clinical workflows, and the clinical decision support systems each conforming to different standard interfaces, detailing a mapping mechanism for every one of them introduces significant work and, thus, limits the potential health benefits of medical devices. In this paper, to facilitate the interoperability of clinical applications and the medical device data, we use the ISO/IEEE 11073 DIM to derive an HL7 v3 Refined Message Information Model (RMIM) of the medical device domain from the HL7 v3 Reference Information Mode (RIM). This makes it possible to trace the medical device data back to a standard common denominator, that is, HL7 v3 RIM from which all the other medical domains under HL7 v3 are derived. Hence, once the medical device data are obtained in the RMIM format, it can easily be transformed into HL7-based standard interfaces through XML transformations because these interfaces all have their building blocks from the same RIM. To demonstrate this, we provide the mappings from the developed RMIM to some of the widely used HL7 v3-based standard interfaces.

  6. Open-Source Medical Devices (OSMD) Design of a Small Animal Radiotherapy System

    Science.gov (United States)

    Prajapati, S.; Mackie, T. R.; Jeraj, R.

    2014-03-01

    Open-Source Medical Devices (OSMD) was initiated with the goal of facilitating medical research by developing medical technologies including both hardware and software on an open-source platform. Our first project was to develop an integrated imaging and radiotherapy device for small animals that includes computed tomography (CT), positron emission tomography (PET) and radiation therapy (RT) modalities for which technical specifications were defined in the first OSMD conference held in Madison, Wisconsin, USA in December 2011. This paper specifically focuses on the development of a small animal RT (micro-RT) system by designing a binary micro multileaf collimator (bmMLC) and a small animal treatment planning system (SATPS) to enable intensity modulated RT (IMRT). Both hardware and software projects are currently under development and their current progresses are described. After the development, both bmMLC and TPS will be validated and commissioned for a micro-RT system. Both hardware design and software development will be open-sourced after completion.

  7. 21 CFR 801.128 - Exceptions or alternatives to labeling requirements for medical devices held by the Strategic...

    Science.gov (United States)

    2010-04-01

    ... requirements for medical devices held by the Strategic National Stockpile. 801.128 Section 801.128 Food and... requirements for medical devices held by the Strategic National Stockpile. (a) The appropriate FDA Center... Strategic National Stockpile. (b)(1)(i) A Strategic National Stockpile official or any entity that...

  8. Comparison of Transplant Waitlist Outcomes for Pediatric Candidates Supported by Ventricular Assist Devices Versus Medical Therapy.

    Science.gov (United States)

    Law, Sabrina P; Oron, Assaf P; Kemna, Mariska S; Albers, Erin L; McMullan, D Michael; Chen, Jonathan M; Law, Yuk M

    2018-05-01

    Ventricular assist devices have gained popularity in the management of refractory heart failure in children listed for heart transplantation. Our primary aim was to compare the composite endpoint of all-cause pretransplant mortality and loss of transplant eligibility in children who were treated with a ventricular assist device versus a medically managed cohort. This was a retrospective cohort analysis. Data were obtained from the Scientific Registry of Transplant Recipients. The at-risk population (n = 1,380) was less than 18 years old, either on a ventricular assist device (605 cases) or an equivalent-severity, intensively medically treated group (referred to as MED, 775 cases). None. The impact of ventricular assist devices was estimated via Cox proportional hazards regression (hazard ratio), dichotomizing 1-year outcomes to "poor" (22%: 193 deaths, 114 too sick) versus all others (940 successful transplants, 41 too healthy, 90 censored), while adjusting for conventional risk factors. Among children 0-12 months old, ventricular assist device was associated with a higher risk of poor outcomes (hazard ratio, 2.1; 95% CI, 1.5-3.0; p comparative study of ventricular assist devices versus medical therapy in children. Age is a significant modulator of waitlist outcomes for children with end-stage heart failure supported by ventricular assist device, with the impact of ventricular assist devices being more beneficial in adolescents.

  9. Regulation E 69-14. Monitoring requirements for medical devices

    International Nuclear Information System (INIS)

    2015-01-01

    In the 'Regulations for the State Evaluation and Registration of Medical Equipment' force (Hereinafter Rules) set forth in Chapter VII, Articles 79 and 86, the monitoring activity as one of the programs necessary for evaluating the safety and effectiveness of medical monitoring equipment. In the years 2008 and 2011 were approved and implemented by the Center for State Control of Medical Equipment (CCEEM) Regulations and -1.1 ER and ER-1 that support and regulatory requirements 'Control and monitoring of pacemakers and implantable defibrillators' and 'Assessment, recording and control after market surgical silicone implants,' which are specific to these products and have provided a useful result for the performance of the activity. Given the number and diversity of high-risk medical devices as implantable or sustain human life that are brought into our National Health System (SNS), a regulation establishing control over the behavior becomes necessary safety and effectiveness of this equipment during use, which provide inputs to risk management. The objective of this regulation is to establish the regulatory requirements for tracking medical equipment introduced in the NHS. The provisions of this Regulation is aimed at health institutions, to CECMED as manufacturers, suppliers, distributors and importers of medical equipment.

  10. Cytotoxicity of ophthalmic solutions with and without preservatives to human corneal endothelial cells, epithelial cells and conjunctival epithelial cells.

    Science.gov (United States)

    Ayaki, Masahiko; Yaguchi, Shigeo; Iwasawa, Atsuo; Koide, Ryohei

    2008-08-01

    The cytotoxicity of a range of commercial ophthalmic solutions in the presence and absence of preservatives was assessed in human corneal endothelial cells (HCECs), corneal epithelia and conjunctival epithelia using in vitro techniques. Cell survival was measured using the WST-1 assay for endothelial cells and the MTT assay for epithelial cells. Commercially available timolol, carteolol, cromoglicate, diclofenac, bromfenac and hyaluronic acid ophthalmic solutions were assessed for cytotoxicity in the presence and absence of preservatives. The preservatives benzalkonium, chlorobutanol and polysorbate were also tested. The survival of cells exposed to test ophthalmic solutions was expressed as a percentage of cell survival in the control solution (distilled water added to media) after 48 h exposure. HCEC survival was 20-30% in ophthalmic solutions diluted 10-fold. The survival of HCEC was significantly greater in all solutions in the absence of preservative than in the presence of preservative. The survival of corneal and conjunctival epithelia was consistent with that of HCECs for all test ophthalmic solutions. The preservatives polysorbate and benzalkonium were highly cytotoxic with cell survival decreasing to 20% at the concentration estimated in commercial ophthalmic solutions. By comparison, the survival of cells exposed to chlorobutanol was 80% or greater. The cytotoxicity of ophthalmic solutions to HCEC, corneal epithelia and conjunctival epithelia decreased in the absence of preservative.

  11. 21 CFR 610.42 - Restrictions on use for further manufacture of medical devices.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Restrictions on use for further manufacture of medical devices. 610.42 Section 610.42 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH... for Communicable Disease Agents § 610.42 Restrictions on use for further manufacture of medical...

  12. Evaluation of the cytotoxic effects of ophthalmic solutions containing benzalkonium chloride on corneal epithelium using an organotypic 3-D model.

    Science.gov (United States)

    Khoh-Reiter, Su; Jessen, Bart A

    2009-07-28

    Benzalkonium chloride (BAC) is a common preservative used in ophthalmic solutions. The aim of this study was to compare the cytotoxic effects of BAC-containing ophthalmic solutions with a BAC-free ophthalmic solution using an organotypic 3-dimensional (3-D) corneal epithelial model and to determine the effects of latanoprost ophthalmic solution and its BAC-containing vehicle on corneal thickness in a monkey model. The cytotoxicity of commercially available BAC-containing ophthalmic formulations of latanoprost (0.02% BAC) and olopatadine (0.01% BAC) was compared to that of BAC-free travoprost and saline in a corneal organotypic 3-D model using incubation times of 10 and 25 minutes. To compare the extent of differentiation of 3-D corneal cultures to monolayer transformed human corneal epithelial (HCE-T) cell cultures, expression levels (mRNA and protein) of the corneal markers epidermal growth factor receptor, transglutaminase 1 and involucrin were quantified. Finally, latanoprost ophthalmic solution or its vehicle was administered at suprapharmacologic doses (two 30 microL drops twice daily in 1 eye for 1 year) in monkey eyes, and corneal pachymetry was performed at baseline and at weeks 4, 13, 26 and 52. In the 3-D corneal epithelial culture assays, there were no significant differences in cytotoxicity between the BAC-containing latanoprost and olopatadine ophthalmic solutions and BAC-free travoprost ophthalmic solution at either the 10- or 25-minute time points. The 3-D cultures expressed higher levels of corneal epithelial markers than the HCE-T monolayers, indicating a greater degree of differentiation. There were no significant differences between the corneal thickness of monkey eyes treated with latanoprost ophthalmic solution or its vehicle (both containing 0.02% BAC) and untreated eyes. The lack of cytotoxicity demonstrated in 3-D corneal cultures and in monkey studies suggests that the levels of BAC contained in ophthalmic solutions are not likely to cause

  13. Evaluation of the cytotoxic effects of ophthalmic solutions containing benzalkonium chloride on corneal epithelium using an organotypic 3-D model

    Directory of Open Access Journals (Sweden)

    Jessen Bart A

    2009-07-01

    Full Text Available Abstract Background Benzalkonium chloride (BAC is a common preservative used in ophthalmic solutions. The aim of this study was to compare the cytotoxic effects of BAC-containing ophthalmic solutions with a BAC-free ophthalmic solution using an organotypic 3-dimensional (3-D corneal epithelial model and to determine the effects of latanoprost ophthalmic solution and its BAC-containing vehicle on corneal thickness in a monkey model. Methods The cytotoxicity of commercially available BAC-containing ophthalmic formulations of latanoprost (0.02% BAC and olopatadine (0.01% BAC was compared to that of BAC-free travoprost and saline in a corneal organotypic 3-D model using incubation times of 10 and 25 minutes. To compare the extent of differentiation of 3-D corneal cultures to monolayer transformed human corneal epithelial (HCE-T cell cultures, expression levels (mRNA and protein of the corneal markers epidermal growth factor receptor, transglutaminase 1 and involucrin were quantified. Finally, latanoprost ophthalmic solution or its vehicle was administered at suprapharmacologic doses (two 30 μL drops twice daily in 1 eye for 1 year in monkey eyes, and corneal pachymetry was performed at baseline and at weeks 4, 13, 26 and 52. Results In the 3-D corneal epithelial culture assays, there were no significant differences in cytotoxicity between the BAC-containing latanoprost and olopatadine ophthalmic solutions and BAC-free travoprost ophthalmic solution at either the 10- or 25-minute time points. The 3-D cultures expressed higher levels of corneal epithelial markers than the HCE-T monolayers, indicating a greater degree of differentiation. There were no significant differences between the corneal thickness of monkey eyes treated with latanoprost ophthalmic solution or its vehicle (both containing 0.02% BAC and untreated eyes. Conclusion The lack of cytotoxicity demonstrated in 3-D corneal cultures and in monkey studies suggests that the levels of BAC

  14. [Study on restriction factors and countermeasures of influence of China medical devices competitiveness].

    Science.gov (United States)

    Zhang, Zhijun

    2012-07-01

    Recent years, China medical devices industry has been a sunrise industry with widely-ranged products, high-tech innovation, and booming market demands. But with the globalization of market economy, China industry is still in the inferior position of competition. How to promote the industrial structure transition, increase scientific and technological level, speed up the updating of products, enhance the international competitiveness is one of the major tasks to maintain the healthy development of industry. This article makes a study on current situation of China medical devices industry, analyses the new opportunities, challenges and restriction factors, provides the countermeasures of strengthening industry competitiveness as well.

  15. A systematic review of electronic multi-compartment medication devices with reminder systems for improving adherence to self-administered medications.

    Science.gov (United States)

    Paterson, Mary; Kinnear, Moira; Bond, Christine; McKinstry, Brian

    2017-06-01

    Many patients experience difficulties adhering to medication regimes. For people who forget or get confused about medication, there are products to help them such as multi-compartment medication devices (MMDs). Some of these, known as electronic MMDs (eMMDs), use audible and/or visual signals to prompt the patient when to take medication, dispense medications, give instructions to the patient, and contact a caregiver (mobile Internet or text to a carer) as needed. To systematically review the literature on the use of eMMDs, to determine what evidence for their effectiveness is available. A comprehensive literature search of 10 databases, plus an Internet search and hand searching was conducted, using the MeSH terms reminder systems/patient compliance/medication adherence. There were no date restrictions. Inclusion criteria were patients in any community setting, in any country and with no restrictions of age, gender, ethnicity or medical condition, using an eMMD. Peer-reviewed quantitative or qualitative studies of any design were included. Of 805 abstracts identified and 99 full text papers retrieved, six met the inclusion criteria. Five of the studies reported adherence to medication regimes; one reported design factors to improve adherence. Adherence varied by the context of the reminders, the target group and usability of the devices. The studies were small scale and only one was a well conducted randomised controlled trial. Overall methodological quality of the studies was poor. Although positive effects on adherence were reported further, rigorously conducted, studies are needed to inform the use of eMMDs. © 2016 Royal Pharmaceutical Society.

  16. 21 CFR 524.390a - Chloramphenicol ophthalmic ointment.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS... treatment for 48 hours (2 days) after eye appears normal. Therapy for cats should not exceed 7 days... therapy should be considered. When infection may be cause of disease, especially in purulent or catarrhal...

  17. Halo and spillover effect illustrations for selected beneficial medical devices and drugs

    Directory of Open Access Journals (Sweden)

    Brent D. Kerger

    2016-09-01

    Full Text Available Abstract Background Negative news media reports regarding potential health hazards of implanted medical devices and pharmaceuticals can lead to a ‘negative halo effect,’ a phenomenon whereby judgments about a product or product type can be unconsciously altered even though the scientific support is tenuous. To determine how a ‘negative halo effect’ may impact the rates of use and/or explantation of medical products, we analyzed the occurrence of such an effect on three implanted medical devices and one drug: 1 intrauterine contraceptive devices (IUDs; 2 silicone gel-filled breast implants (SGBI; 3 metal-on-metal hip implants (MoM; and 4 the drug Tysabri. Methods Data on IUD use from 1965 to 2008 were gathered from the Department of Health and Human Services Vital and Health Statistics and peer-reviewed publications. Data regarding SGBI implant and explantation rates from 1989 to 2012 were obtained from the Institute of Medicine and the American Society of Plastic Surgeons. MoM implant and explantation data were extracted from the England and Wales National Joint Registry and peer-reviewed publications. Tysabri patient data were reported by Elan Corporation or Biogen Idec Inc. Data trends for all products were compared with historical recall or withdrawal events and discussed in the context of public perceptions following such events. Results We found that common factors altered public risk perceptions and patterns of continued use. First, a negative halo effect may be driven by continuing patient anxiety despite positive clinical outcomes. Second, negative reports about one product can spill over to affect the use of dissimilar products in the same category. Third, a negative halo effect on an entire category of medical devices can be sustained regardless of the scientific findings pertaining to safety. Fourth, recovery of a product’s safety reputation and prevalent use may take decades in the U.S., even while these products may

  18. Risk assessment of medical devices: evaluation of microbiological and toxicological safety

    International Nuclear Information System (INIS)

    Dorpema, J.W.

    1995-01-01

    Safety assessment of medical devices includes sterilization and biological evaluation or biocompatability testing. Sterilization by ETO gas is criticised for their carcinogenic potency or even banned. Mutual acceptance of biological evaluation test results is promoted by a laboratory accreditation and qualification program. (Author)

  19. Integration of human factors and ergonomics during medical device design and development: it's all about communication.

    Science.gov (United States)

    Vincent, Christopher James; Li, Yunqiu; Blandford, Ann

    2014-05-01

    Manufacturers of interactive medical devices, such as infusion pumps, need to ensure that devices minimise the risk of unintended harm during use. However, development teams face challenges in incorporating Human Factors. The aim of the research reported here was to better understand the constraints under which medical device design and development take place. We report the results of a qualitative study based on 19 semi-structured interviews with professionals involved in the design, development and deployment of interactive medical devices. A thematic analysis was conducted. Multiple barriers to designing for safety and usability were identified. In particular, we identified barriers to communication both between the development organisation and the intended users and between different teams within the development organisation. We propose the use of mediating representations. Artefacts such as personas and scenarios, known to provide integration across multiple perspectives, are an essential component of designing for safety and usability. Copyright © 2013 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  20. Doppler sonographic evaluation of ophthalmic arterial flow pattern in hypertensive patients

    International Nuclear Information System (INIS)

    Ryu, Dae Sik; Kim, Young Goo

    1994-01-01

    To compare the Doppler velocity waveform pattern of ophthalmic artery of hypertensive patients with that of normotensive subjects. Doppler velocity waveform was obtained from ophthalmic artery in 45 hypertensive patients and 60 normotensive subjects. Both hypertensives and normotensive subjects were classified according to age into those younger than and those older than 45 years. Doppler indices(pulsatility index(PI), resistance index(RI), the first systolic peak/the second systolic peak(S1/S2), the first systolic peak/diastolic peak(S1/D)) measured in hypertensive patients were compared with normotensive subjects. Among the various doppler indices, only S1/S2 showed significant difference(P < 0.05) between the hypertensive patients and normotensive subjects younger than 45 years. Doppler velocity waveform of hypertensive patients older than 45 years showed no significant difference from that of normotensive subjects with corresponding age. Doppler velocity waveform of ophthalmic artery in hypertensive patients younger than 45 years shows pattern with S2 higher than that of normotensive subjects. High S2 component(reflective-wave) may represent increased vascular impedance due to vasococonstriction of retinal arterioles in hypertensive patients

  1. The Role of Healthcare Technology Management in Facilitating Medical Device Cybersecurity.

    Science.gov (United States)

    Busdicker, Mike; Upendra, Priyanka

    2017-09-02

    This article discusses the role of healthcare technology management (HTM) in medical device cybersecurity and outlines concepts that are applicable to HTM professionals at a healthcare delivery organization or at an integrated delivery network, regardless of size. It provides direction for HTM professionals who are unfamiliar with the security aspects of managing healthcare technologies but are familiar with standards from The Joint Commission (TJC). It provides a useful set of recommendations, including relevant references for incorporating good security practices into HTM practice. Recommendations for policies, procedures, and processes referencing TJC standards are easily applicable to HTM departments with limited resources and to those with no resource concerns. The authors outline processes from their organization as well as best practices learned through information sharing at AAMI, National Health Information Sharing and Analysis Center (NH-ISAC), and Medical Device Innovation, Safety, and Security Consortium (MDISS) conferences and workshops.

  2. Influence of Mobile Phones on the Quality of ECG Signal Acquired by Medical Devices

    Science.gov (United States)

    Buczkowski, T.; Janusek, D.; Zavala-Fernandez, H.; Skrok, M.; Kania, M.; Liebert, A.

    2013-10-01

    Health aspects of the use of radiating devices, like mobile phones, are still a public concern. Stand-alone electrocardiographic systems and those built-in, more sophisticated, medical devices have become a standard tool used in everyday medical practice. GSM mobile phones might be a potential source of electromagnetic interference (EMI) which may affect reliability of medical appliances. Risk of such event is particularly high in places remote from GSM base stations in which the signal received by GSM mobile phone is weak. In such locations an increase in power of transmitted radio signal is necessary to enhance quality of the communication. In consequence, the risk of interference of electronic devices increases because of the high level of EMI. In the present paper the spatial, temporal, and spectral characteristics of the interference have been examined. The influence of GSM mobile phone on multilead ECG recordings was studied. It was observed that the electrocardiographic system was vulnerable to the interference generated by the GSM mobile phone working with maximum transmit power and in DTX mode when the device was placed in a distance shorter than 7.5 cm from the ECG electrode located on the surface of the chest. Negligible EMI was encountered at any longer distance.

  3. Improvised explosive devices: pathophysiology, injury profiles and current medical management.

    Science.gov (United States)

    Ramasamy, A; Hill, A M; Clasper, J C

    2009-12-01

    The improvised explosive device (IED), in all its forms, has become the most significant threat to troops operating in Afghanistan and Iraq. These devices range from rudimentary home made explosives to sophisticated weapon systems containing high-grade explosives. Within this broad definition they may be classified as roadside explosives and blast mines, explosive formed pojectile (EFP) devices and suicide bombings. Each of these groups causeinjury through a number of different mechanisms and can result in vastly different injury profiles. The "Global War on Terror" has meant that incidents which were previously exclusively seen in conflict areas, can occur anywhere, and clinicians who are involved in emergency trauma care may be required to manage casualties from similar terrorist attacks. An understanding of the types of devices and their pathophysiological effects is necessary to allow proper planning of mass casualty events and to allow appropriate management of the complex poly-trauma casualties they invariably cause. The aim of this review article is to firstly describe the physics and injury profile from these different devices and secondly to present the current clinical evidence that underpins their medical management.

  4. Cost effectiveness of medical devices to diagnose pre-eclampsia in low-resource settings

    Directory of Open Access Journals (Sweden)

    Zoë M. McLaren

    Full Text Available Background: Maternal mortality remains a major health challenge facing developing countries, with pre-eclampsia accounting for up to 17% of maternal deaths. Diagnosis requires skilled health providers and devices that are appropriate for low-resource settings. This study presents the first cost-effectiveness analysis of multiple medical devices used to diagnose pre-eclampsia in low- and middle-income countries (LMICs. Methods: Blood pressure and proteinuria measurement devices, identified from compendia for LMICs, were included. We developed a decision tree framework to assess the cost-effectiveness of each device using parameter values that reflect the general standard of care based on a survey of relevant literature and expert opinion. We examined the sensitivity of our results using one-way and second-order probabilistic multivariate analyses. Results: Because the disability-adjusted life years (DALYs averted for each device were very similar, the results were influenced by the per-use cost ranking. The most cost-effective device combination was a semi-automatic blood pressure measurement device and visually read urine strip test with the lowest combined per-use cost of $0.2004 and an incremental cost effectiveness ratio of $93.6 per DALY gained relative to a baseline with no access to diagnostic devices. When access to treatment is limited, it is more cost-effective to improve access to treatment than to increase testing rates or diagnostic device sensitivity. Conclusions: Our findings were not sensitive to changes in device sensitivity, however they were sensitive to changes in the testing rate and treatment rate. Furthermore, our results suggest that simple devices are more cost-effective than complex devices. The results underscore the desirability of two design features for LMICs: ease of use and accuracy without calibration. Our findings have important implications for policy makers, health economists, health care providers and

  5. Effects of Sterilization Cycles on PEEK for Medical Device Application

    Science.gov (United States)

    Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-01-01

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed. PMID:29466289

  6. Effects of Sterilization Cycles on PEEK for Medical Device Application.

    Science.gov (United States)

    Kumar, Amit; Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-02-21

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed.

  7. 76 FR 51876 - Medical Devices; Ophthalmic Devices; Classification of the Eyelid Thermal Pulsation System

    Science.gov (United States)

    2011-08-19

    ... of exposure to non- ionizing radiation; (2) Design, description, and performance data should validate.../testing should validate electromagnetic compatibility (EMC) and safety of exposure to non-ionizing.... Malfunction Non-clinical and Clinical Performance Testing. User error Labeling. FDA believes that the...

  8. Analysis of medical device materials with the local electrode atom probe

    International Nuclear Information System (INIS)

    Goodman, S.L.; Mengelt, T.J.; Ali, M.; Ulfig, R.M.; Martens, R.M.; Kelly, T.F.; Kostrna, S.L.P.; Kostrna, M.S.; Carmichael, W.J.

    2004-01-01

    Full text: As medical technology advances towards microsurgical and minimally invasive techniques, there is a drive to produce ever-smaller devices that demand higher material performance and hence enhanced nano and micro-scale control of material structure. These devices are made from stainless steel alloys, Nitinol, titanium, CoCrMo, and non-metals such as pyrolytic carbon and silicon. These applications are made possible due to suitable physical and mechanical properties, good corrosion resistance in biological environments, reasonable biocompatibility, and good manufacturability. With respect to the metals, the nano-structure and composition of the material surface, typically an oxide, is especially critical since biological responses and corrosion occur at the material-environment interface. Thus, there is an increasing need to understand the 3-D structure and composition of metallic biomaterials at the atomic scale. Three-dimensional atom probe microscopy can uniquely provide such atomic-level structural information. In the present study several of these medical device materials were examined. These include a 316L stainless steel alloy which is widely used in implanted spinal fixation devices, bone screws, cardiovascular and neurological stents, a cast CoCrMo acetabular hip cup of a Cormet metal-on-metal Hip Resurfacing System (Corin Group, Cirencester, England) that was rejected for clinical use, Nitinol wires specimens such as are used for stents and guide wires, and low temperature pyrolytic carbon as used in clinical heart valve prosthetics. (author)

  9. New Zealand health reforms: effect on ophthalmic practice.

    Science.gov (United States)

    Raynel, S; Reynolds, H

    1999-01-01

    Are specialized ophthalmic units with inpatient facilities going to disappear in the New Zealand public health system? We have entered the era of cost containment, business methodologies, bench marking, day case surgery, and technologic advances. The dilemma for nursing is maintenance of a skill base with dwindling clinical practice areas.

  10. Epigenetic Treatment of Neurodegenerative Ophthalmic Disorders: An Eye Toward the Future.

    Science.gov (United States)

    Moos, Walter H; Faller, Douglas V; Glavas, Ioannis P; Harpp, David N; Irwin, Michael H; Kanara, Iphigenia; Pinkert, Carl A; Powers, Whitney R; Steliou, Kosta; Vavvas, Demetrios G; Kodukula, Krishna

    2017-01-01

    Eye disease is one of the primary medical conditions that requires attention and therapeutic intervention in ageing populations worldwide. Further, the global burden of diabetes and obesity, along with heart disease, all lead to secondary manifestations of ophthalmic distress. Therefore, there is increased interest in developing innovative new approaches that target various mechanisms and sequelae driving conditions that result in adverse vision. The research challenge is even greater given that the terrain of eye diseases is difficult to landscape into a single therapeutic theme. This report addresses the burden of eye disease due to mitochondrial dysfunction, including antioxidant, autophagic, epigenetic, mitophagic, and other cellular processes that modulate the biomedical end result. In this light, we single out lipoic acid as a potent known natural activator of these pathways, along with alternative and potentially more effective conjugates, which together harness the necessary potency, specificity, and biodistribution parameters required for improved therapeutic outcomes.

  11. 76 FR 67463 - Pediatric Medical Devices; Public Workshop; Request for Comments

    Science.gov (United States)

    2011-11-01

    ... use, existing scientific research data to determine pediatric effectiveness based on a similar course... research data, and C. The methods to overcome the pitfalls and data gaps, including statistical approaches... announcing a public workshop entitled ``Using Scientific Research Data to Support Pediatric Medical Device...

  12. Gatifloxacin Ophthalmic Solution for Treatment of Bacterial Conjunctivitis: Safety, Efficacy and Patient Perspective

    OpenAIRE

    Clyde Schultz

    2012-01-01

    Gatifloxacin is a fourth generation fluroquinolone antibiotic that has been prescribed for systemic use. However, the drug which was developed by Kyorin (Japan) was linked to toxic reactions and death and was banned in the United States and Canada for use as an oral dosage form. It continues to be used as a topical application for ophthalmic conditions as the systemic toxicity seen when taking the drug orally has not been observed with ophthalmic use. The available data indicate that ocular u...

  13. Approval of devices and facilities using ionizing radiations for medical purposes

    International Nuclear Information System (INIS)

    1977-01-01

    This Order made by the Ministers of Health and Social Security, Agriculture and Labour amends a previous Decree of 23 April 1969 in particular concerning the classification of medical or dental radiodiagnostic devices subject to approval. The technical conditions to be complied with for such devices and facilities have also been amended. Finally, it is provided that, as regards facilities with heavy equipment subject to licensing (Act of 31 December 1970), approval is subject to compliance with the licensing conditions and is requested together with the application for a licence. (NEA) [fr

  14. Preoperative Hand Decontamination in Ophthalmic Surgery: A Comparison of the Removal of Bacteria from Surgeons' Hands by Routine Antimicrobial Scrub versus an Alcoholic Hand Rub.

    Science.gov (United States)

    Forer, Yaara; Block, Colin; Frenkel, Shahar

    2017-09-01

    The goal of this experiment was to evaluate and compare the antimicrobial efficacy of routine preoperative hand washing using commercial medicated sponge brushes versus an alcoholic hand rub, by comparing bacterial growth on ophthalmic surgeons' hands after application of each of these methods. Twenty ophthalmic surgeons were recruited at the Hadassah-Hebrew University Medical Center in Jerusalem, Israel. Samples were collected twice from the hands of each surgeon after hand decontamination using two different protocols during routine surgical practice. The routine preparation consisted of a 3-minute surgical scrub using commercial brush-sponges incorporating either 4% chlorhexidine gluconate (CHG) or 1% povidone-iodine (PVP-I) formulations with detergent, followed by drying the hands with a sterile towel, while the 70% ethanol solution was applied for 60-seconds and allowed to air dry. Half of the group was randomly assigned to provide samples first after the routine method and the alcoholic solution a week later, and the other half of the group was sampled in the reverse order. Viable counts of bacteria were evaluated using a modified glove juice method. Bacterial colonies were enumerated after incubation for 24 hours and expressed as colony forming units (CFU)/mL for each pair of hands. Geometric mean counts were 1310 and 39 CFU/mL, in the routine and alcohol rub groups, respectively, representing a mean log 10 reduction in 1.53. The difference between the paired bacterial counts for the routine versus the alcohol rub was statistically significant (p surgical hand preparation with PVP-I and CHG in a population of practicing ophthalmic surgeons in the operative clinical setting. Thus, it provides a safe alternative as a preoperative hand disinfection method.

  15. A balancing act: a phenomenological exploration of medical students' experiences of using mobile devices in the clinical setting.

    Science.gov (United States)

    Rashid-Doubell, F; Mohamed, S; Elmusharaf, K; O'Neill, C S

    2016-05-03

    The aims of this study were to describe the experiences of senior students using mobile devices in a clinical setting while learning and interacting with clinical teachers, patients and each other, and to identify challenges that facilitated or impeded the use of such devices in the hospital. Interpretative phenomenology was chosen to guide our enquiry. Semi-structured interviews were conducted to examine the experiences of five senior medical students using mobile devices in the clinical setting. Senior medical students at an international medical school in the Middle East. Three main themes emerged from the data analysis: learning; professional identity and transitioning from student to doctor. The findings showed that using mobile devices in the clinical area as a learning tool was not a formalised process. Rather, it was opportunistic learning at the bedside and on occasion a source of distraction from clinical teaching. Students needed to negotiate relationships between themselves, the clinical teacher and patients in order to ensure that they maintained an acceptable professional image. Participants experienced and negotiated the change from student to doctor making them mindful of using their devices at the bedside. Mobile devices are part of daily life for a medical student and there is a need to adapt medical education in the clinical setting, to allow the students to use their devices in a sensitive manner. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  16. Ophthalmic Morbidity in School Children in Hilly Areas of Uttarakhand

    Directory of Open Access Journals (Sweden)

    Surekha Kishore

    2014-03-01

    Full Text Available Introduction: School children constitute about one fourth of population of India. Early detection and treatment of various eye diseases helps in avoiding many complications. The magnitude of blindness is 3-4 times greater in developing countries. Very few studies have been conducted in Uttarakhand revealing the ophthalmic morbidity in school children or general population. Hilly areas especially the remote ones face various problems like, poor transportation facilities, distant health facilities, use of traditional methods for treatment, faith healing, customs and belief system, lack of information.  Moreover   water supply, poor personal hygiene and other factors also add up to these problems. Aim: To study the ophthalmic morbidities in school children in 3 schools of Thatyur block. Methodology: It was a cross sectional study. Result: A total of 705 students were enrolled. Permission from school authorities was seeked before the start of study. Schools were visited twice in a week current and preliminary information was taken from the students & teacher regarding education, occupation, income etc. General examination and ophthalmic examination was done with day & torch light along with refraction, with the help of standard Snellen’s chart. Each eye was examined separately. A vision of 6/6 was considered as normal. Near vision was tested with new vision Snellen’s chart at 12-14 inches away from eye.

  17. Ophthalmic Morbidity in School Children in Hilly Areas of Uttarakhand

    Directory of Open Access Journals (Sweden)

    Surekha Kishore

    2014-03-01

    Full Text Available Introduction: School children constitute about one fourth of population of India. Early detection and treatment of various eye diseases helps in avoiding many complications. The magnitude of blindness is 3-4 times greater in developing countries. Very few studies have been conducted in Uttarakhand revealing the ophthalmic morbidity in school children or general population. Hilly areas especially the remote ones face various problems like, poor transportation facilities, distant health facilities, use of traditional methods for treatment, faith healing, customs and belief system, lack of information.  Moreover   water supply, poor personal hygiene and other factors also add up to these problems. Aim: To study the ophthalmic morbidities in school children in 3 schools of Thatyur block. Methodology: It was a cross sectional study. Result: A total of 705 students were enrolled. Permission from school authorities was seeked before the start of study. Schools were visited twice in a week current and preliminary information was taken from the students & teacher regarding education, occupation, income etc. General examination and ophthalmic examination was done with day & torch light along with refraction, with the help of standard Snellen’s chart. Each eye was examined separately. A vision of 6/6 was considered as normal. Near vision was tested with new vision Snellen’s chart at 12-14 inches away from eye.

  18. Re-evaluation of Magnetic Resonance and Computerised Tomographic Imaging in Neuro-Ophthalmic Patients in an Academic Centre

    NARCIS (Netherlands)

    Koekoek, Clarence G. J.; Meiners, Linda C.; Pott, Jan Willem R.

    The aim of the study is to report the frequency of missed diagnoses on magnetic resonance and computerised tomographic imaging in neuro-ophthalmic patients who were referred to an academic ophthalmology department, with apparent normal imaging. The authors included all neuro-ophthalmic patients,

  19. Medical diagnostics with mobile devices: Comparison of intrinsic and extrinsic sensing.

    Science.gov (United States)

    Kwon, L; Long, K D; Wan, Y; Yu, H; Cunningham, B T

    2016-01-01

    We review the recent development of mobile detection instruments used for medical diagnostics, and consider the relative advantages of approaches that utilize the internal sensing capabilities of commercially available mobile communication devices (such as smartphones and tablet computers) compared to those that utilize a custom external sensor module. In this review, we focus specifically upon mobile medical diagnostic platforms that are being developed to serve the need in global health, personalized medicine, and point-of-care diagnostics. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Brazilian demand for Iodine-125 seeds in cancer treatment after a decade of medical procedures

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Osvaldo L. da; Souza, Daiane C.B. de; Feher, Anselmo; Moura, João A.; Souza, Carla D.; Oliveira, Henrique B. de; Peleiras Junior, Fernando S.; Zeituni, CArlos A.; Rostelaro, Maria E.C.M., E-mail: olcosta@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Iodine-125 and palladium-103 are radionuclides employed to made medical devices used in cancer treatment known as brachytherapy seeds. These radioactive sealed sources are applied in brain and ophthalmic cancer as a temporary implant to irradiate the tumor and in permanent implants to prostatic cancer. Brazilian Nuclear Energy Commission (CNEN) has the monopoly in Brazil of iodine-125 brachytherapy seeds distribution which is executed for Nuclear and Energy Research Institute (IPEN-CNEN/SP). Along a decade of use in Brazil more than 240 thousand seeds were implanted in patients or used to treat cancer tumors. In this article the Brazilian demand for iodine-125 brachytherapy seeds is analyzed. The demand behavior along a decade of using loose, strand, ophthalmic and brain brachytherapy seeds are shown. The annual quantity of seeds demanded by Brazil has dropped since 2012. The loose seeds which represented until 30% from total brachytherapy seeds used in Brazil decreased to less than 3%. The brain brachytherapy seeds had low demand along the decade and presented zero demand in several years. Concurrent treatment techniques are listed and main trends are discussed. The influence of Brazilian economic crisis and the demand behavior of the main hospitals and clinics that use Iodine-125 brachytherapy are shown. (author)

  1. Brazilian demand for Iodine-125 seeds in cancer treatment after a decade of medical procedures

    International Nuclear Information System (INIS)

    Costa, Osvaldo L. da; Souza, Daiane C.B. de; Feher, Anselmo; Moura, João A.; Souza, Carla D.; Oliveira, Henrique B. de; Peleiras Junior, Fernando S.; Zeituni, CArlos A.; Rostelaro, Maria E.C.M.

    2017-01-01

    Iodine-125 and palladium-103 are radionuclides employed to made medical devices used in cancer treatment known as brachytherapy seeds. These radioactive sealed sources are applied in brain and ophthalmic cancer as a temporary implant to irradiate the tumor and in permanent implants to prostatic cancer. Brazilian Nuclear Energy Commission (CNEN) has the monopoly in Brazil of iodine-125 brachytherapy seeds distribution which is executed for Nuclear and Energy Research Institute (IPEN-CNEN/SP). Along a decade of use in Brazil more than 240 thousand seeds were implanted in patients or used to treat cancer tumors. In this article the Brazilian demand for iodine-125 brachytherapy seeds is analyzed. The demand behavior along a decade of using loose, strand, ophthalmic and brain brachytherapy seeds are shown. The annual quantity of seeds demanded by Brazil has dropped since 2012. The loose seeds which represented until 30% from total brachytherapy seeds used in Brazil decreased to less than 3%. The brain brachytherapy seeds had low demand along the decade and presented zero demand in several years. Concurrent treatment techniques are listed and main trends are discussed. The influence of Brazilian economic crisis and the demand behavior of the main hospitals and clinics that use Iodine-125 brachytherapy are shown. (author)

  2. Oxidative-stress detoxification and signalling in cyanobacteria: the crucial glutathione synthesis pathway supports the production of ergothioneine and ophthalmate.

    Science.gov (United States)

    Narainsamy, Kinsley; Farci, Sandrine; Braun, Emilie; Junot, Christophe; Cassier-Chauvat, Corinne; Chauvat, Franck

    2016-04-01

    Using genetics and metabolomics we investigated the synthesis (gshA and gshB genes) and catabolism (ggt) of the conserved antioxidant glutathione in the model cyanobacterium Synechocystis PCC6803. These three genes are crucial to Synechocystis, in agreement with the proposed invention of glutathione by ancient cyanobacteria to protect themselves against the toxicity of oxygen they produced through photosynthesis. Consistent with their indispensability, gshA and gshB also operate in the production of another antioxidant, ergothioneine, as well as of the glutathione analogues ophthalmate and norophthalmate. Furthermore, we show that glutathione, ophthalmate and norophthalmate are accumulated in cells stressed by glucose, and that the two glutathione-dependent glyoxalase enzymes operate in the protection against glucose and its catabolite methylglyoxal. These findings are interesting because ophthalmate and norophthalmate were observed only in mammals so far, where ophthalmate is regarded as a biomarker of glutathione depletion. Instead, our data suggest that ophthalmate and norophthalmate are stress-induced markers of cysteine depletion triggered by its accelerated incorporation into glutathione, to face its increased demand for detoxification purposes. Hence, Synechocystis is an attractive model for the analysis of the role of glutathione, ergothioneine, ophthalmate and norophthalmate, in signalling and detoxification of oxidants and metabolic by-products. © 2015 John Wiley & Sons Ltd.

  3. 77 FR 52742 - Public Meeting-Strengthening the National Medical Device Postmarket Surveillance System; Request...

    Science.gov (United States)

    2012-08-30

    ... Contact Person) no later than September 5, 2012. No commercial or promotional material will be permitted... develop and implement a comprehensive medical device postmarket surveillance strategy to collect, analyze... implementing this strategy, FDA is holding a public meeting to discuss the current and future state of medical...

  4. Assurance of Medical Device Quality with Quality Management System: An Analysis of Good Manufacturing Practice Implementation in Taiwan

    Directory of Open Access Journals (Sweden)

    Tzu-Wei Li

    2015-01-01

    Full Text Available The implementation of an effective quality management system has always been considered a principal method for a manufacturer to maintain and improve its product and service quality. Globally many regulatory authorities incorporate quality management system as one of the mandatory requirements for the regulatory control of high-risk medical devices. The present study aims to analyze the GMP enforcement experience in Taiwan between 1998 and 2013. It describes the regulatory implementation of medical device GMP requirement and initiatives taken to assist small and medium-sized enterprises in compliance with the regulatory requirement. Based on statistical data collected by the competent authority and industry research institutes, the present paper reports the growth of Taiwan local medical device industry after the enforcement of GMP regulation. Transition in the production, technologies, and number of employees of Taiwan medical device industry between 1998 and 2013 provides the competent authorities around the world with an empirical foundation for further policy development.

  5. Potential negative consequences of non-consented switch of inhaled medications and devices in asthma patients.

    Science.gov (United States)

    Björnsdóttir, U S; Gizurarson, S; Sabale, U

    2013-09-01

    Asthma requires individually tailored and careful management to control and prevent symptoms and exacerbations. Selection of the most appropriate treatment is dependent on both the choice of drugs and inhaler device; however, financial pressures may result in patients being switched to alternative medications and devices in an attempt to reduce costs. This review aimed to examine the published literature in order to ascertain whether switching a patient's asthma medications or device negatively impacts clinical and economic outcomes. A literature search of MEDLINE (2001-13 September 2011) was conducted to identify English-language articles focused on the direct impact of switching medications and inhaler devices and switching from fixed-dose combination to monocomponent therapy via separate inhalers in patients with asthma; the indirect impacts of switching were also assessed. Evidence showed that non-consented switching of medications and inhalers in patients with asthma can be associated with a range of negative outcomes, at both individual and organisational levels. Factors that reduce adherence may lead to compromised symptom control resulting in increased healthcare resource utilisation and poorer patient quality of life. The consequences of a non-consented switch should be weighed carefully against arguments supporting an inhaler switch without the patient's consent for non-medical/budgetary reasons, such as potential reductions in initial acquisition costs, which may be associated with subsequent additional healthcare needs. Given the increasing pressure for reduced costs and efficient allocation of limited healthcare resources, an additional investment in ensuring high medication adherence may lead to greater savings due to a potentially decreased demand for healthcare services. In contrast, savings achieved in acquisition costs may result in a greater net loss due to increased healthcare consumption caused by decreased asthma control. © 2013 The Authors

  6. Adherence to hydroxyurea medication by children with sickle cell disease (SCD) using an electronic device: a feasibility study.

    Science.gov (United States)

    Inoue, Susumu; Kodjebacheva, Gergana; Scherrer, Tammy; Rice, Gary; Grigorian, Matthew; Blankenship, Jeremy; Onwuzurike, Nkechi

    2016-08-01

    Adherence to hydroxyurea (HU) is a significant modifying factor in sickle cell vaso-occlusive pain. We conducted a study using an electronic medication container-monitor-reminder device (GlowCap™) to track adherence and determine whether use of this device affected rates of HU adherence. Subjects were regular attendees to our clinic. They were given a 37-item questionnaire and were asked to use a GlowCap containing HU. When the device cap is opened, it makes a remote "medication taken" record. The device also provides usage reminder in the form of lights and alarm sounds if the cap opening is delayed. Nineteen subjects participated in the survey, and 17 in the intervention phase. Of the 17, 12 had reliable adherence data. Seventeen caregivers of patients and two patients completed the survey. Two most common barriers to adherence identified were lack of reminders and absence of medicine home delivery. The intervention component of this study, which used both the electronic (GlowCap) method and medication possession ratio showed that the median adherence rate for the 12 patients evaluated was 85 %. The GlowCap device accurately kept a record of adherence rates. This device may be an effective tool for increasing HU medication adherence.

  7. The effects of cosmic radiation on implantable medical devices

    International Nuclear Information System (INIS)

    Bradley, P.

    1996-01-01

    Metal oxide semiconductor (MOS) integrated circuits, with the benefits of low power consumption, represent the state of the art technology for implantable medical devices. Three significant sources of radiation are classified as having the ability to damage or alter the behavior of implantable electronics; Secondary neutron cosmic radiation, alpha particle radiation from the device packaging and therapeutic doses(up to 70 Gγ) of high energy radiation used in radiation oncology. The effects of alpha particle radiation from the packaging may be eliminated by the use of polyimide or silicone rubber die coatings. The relatively low incidence of therapeutic radiation incident on an implantable device and the use of die coating leaves cosmic radiation induced secondary neutron single event upset (SEU) as the main pervasive ionising radiation threat to the reliability of implantable devices. A theoretical model which predicts the susceptibility of a RAM cell to secondary neutron cosmic radiation induced SEU is presented. The model correlates well within the statistical uncertainty associated with both the theoretical and field estimate. The predicted Soft Error Rate (SER) is 4.8 x l0 -12 upsets/(bit hr) compared to an observed upset rate of 8.5 x 10 -12 upsets/(bit hr) from 20 upsets collected over a total of 284672 device days. The predicted upset rate may increase by up to 20% when consideration is given to patients flying in aircraft The upset rate is also consistent with the expected geographical variations of the secondary cosmic ray neutron flux, although insufficient upsets precluded a statistically significant test. This is the first clinical data set obtained indicating the effects of cosmic radiation on implantable devices. Importantly, it may be used to predict the susceptibility of future to the implantable device designs to the effects of cosmic radiation

  8. Ophthalmic manifestations of head injury.

    Science.gov (United States)

    Kowal, L

    1992-02-01

    Head injuries are frequently associated with ophthalmic problems. The commonest problems seen in this series of 161 patients with head injury were problems with poor accommodation (16% of patients; 58% of these persisted), convergence (14% of patients; 35% of these persisted), pseudomyopia (19%; 55% persisted) and optic atrophy (26% of the patients; 78% of these were mild and easily missed on routine testing, and 22% were severe). Motility disorders were common, especially cranial nerve palsies. Other less frequent motility disturbances included apparent inferior oblique palsy, comitant esotropia, and exotropia which was often of the convergence insufficiency type.

  9. ISO 13485: a complete guide to quality management in the medical device industry

    National Research Council Canada - National Science Library

    Abuhav, Itay

    2012-01-01

    .... Written by an experienced industry professional, this practical book provides a complete guide to the ISO 13485 standard certification for medical device manufacturing in terms of quality control...

  10. Factors that influence the recognition, reporting and resolution of incidents related to medical devices and other healthcare technologies: a systematic review.

    Science.gov (United States)

    Polisena, Julie; Gagliardi, Anna; Urbach, David; Clifford, Tammy; Fiander, Michelle

    2015-03-29

    Medical devices have improved the treatment of many medical conditions. Despite their benefit, the use of devices can lead to unintended incidents, potentially resulting in unnecessary harm, injury or complications to the patient, a complaint, loss or damage. Devices are used in hospitals on a routine basis. Research to date, however, has been primarily limited to describing incidents rates, so the optimal design of a hospital-based surveillance system remains unclear. Our research objectives were twofold: i) to explore factors that influence device-related incident recognition, reporting and resolution and ii) to investigate interventions or strategies to improve the recognition, reporting and resolution of medical device-related incidents. We searched the bibliographic databases: MEDLINE, Embase, the Cochrane Central Register of Controlled Trials and PsycINFO database. Grey literature (literature that is not commercially available) was searched for studies on factors that influence incident recognition, reporting and resolution published and interventions or strategies for their improvement from 2003 to 2014. Although we focused on medical devices, other health technologies were eligible for inclusion. Thirty studies were included in our systematic review, but most studies were concentrated on other health technologies. The study findings indicate that fear of punishment, uncertainty of what should be reported and how incident reports will be used and time constraints to incident reporting are common barriers to incident recognition and reporting. Relevant studies on the resolution of medical errors were not found. Strategies to improve error reporting include the use of an electronic error reporting system, increased training and feedback to frontline clinicians about the reported error. The available evidence on factors influencing medical device-related incident recognition, reporting and resolution by healthcare professionals can inform data collection and

  11. Outsourcing versus in-house maintenance of medical devices: a longitudinal, empirical study.

    Science.gov (United States)

    Miguel-Cruz, Antonio; Rios-Rincón, Adriana; Haugan, Gregory L

    2014-03-01

    To determine what factors have a significant influence on the performance of medical device maintenance outsourcing, and to determine how the performance of external governance structures differs depending on whether a hospital is private or public. This was a longitudinal study of 590 maintenance transactions at 20 hospitals in Bogotá, Colombia, involving 764 medical devices and 72 maintenance service providers. Maintenance performance data (i.e., turn-around time in hours; TAT) for the service providers (either in-house or outsourced) were primarily collected over a 20-month period, from December 2009-August 2011, by means of a monitoring procedure; then, a hazards model was run. The availability of specific repair parts, in-stock, in the city in which the medical devices were located, had a positive impact on the performance of both internal and external governance structures. Online service also had a positive impact on both, with a stronger positive impact on the performance of internal governance than on that of external governance. For transactions governed by external structures, better performance was seen in private hospitals than in public ones. In public health institutions, internal governance showed better performance than external governance. Both internal and external governance structures showed better performance in private healthcare institutions than in public ones. In public health institutions, internal governance shows better performance than external governance; this suggests that healthcare managers should reconsider the trend to eliminate in-house maintenance service staff in public healthcare institutions.

  12. Evaluation of dacryocystorhinostomy using optical coherence tomography and rebamipide ophthalmic suspension

    Directory of Open Access Journals (Sweden)

    Fujimoto M

    2014-08-01

    Full Text Available Masahiro Fujimoto,1 Ken Ogino,1 Chika Miyazaki,1,2 Miou Hirose,1,3 Hiroko Matsuyama,1,4 Takeshi Moritera,1,5 Nagahisa Yoshimura1 1Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, Kyoto, Japan; 2Department of Ophthalmology, Hyogo Prefectural Tsukaguchi Hospital, Hyogo, Japan; 3Department of Ophthalmology, Hyogo Prefectural Amagasaki Hospital, Hyogo, Japan; 4Department of Ophthalmology, National Hospital Organization Himeji Medical Center, Hyogo, Japan; 5Moritera Eye Clinic, Shiga, Japan Purpose: To evaluate the surgical outcome of dacryocystorhinostomy (DCR by measuring the tear meniscus, using optical coherence tomography and rebamipide ophthalmic suspension. Methods: Patients with nasolacrimal obstruction and chronic dacryocystitis who were scheduled for an endonasal DCR underwent tear meniscus examinations before and 2 months after surgery. Vertical scans of the inferior menisci were performed before and at 1, 3, 5, 7, and 10 minutes after the instillation of rebamipide ophthalmic suspension. The tear menisci areas were measured with imaging software. Ten young adults without epiphora formed the control group.Results: Anatomical success was achieved on 22 sides of 21 patients. The patients’ postoperative tear menisci were significantly smaller than the preoperative menisci at all points during the test, and the response to volume loading in the postoperative patients was corrected to nearly that of the young, healthy adults. Nevertheless, the postoperative meniscus area tended to be larger than that of the young adults at all points.Conclusion: The reduced tear meniscus area after DCR reflected the success of the surgical procedure. However, incomplete recovery of the meniscus after the test might suggest a residual disorder of the lacrimal drainage system after DCR. Keywords: dacryocystorhinostomy, tear meniscus, rebamipide, optical coherence tomography

  13. 21 CFR 524.1484a - Neomycin sulfate ophthalmic ointment.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS OPHTHALMIC AND TOPICAL DOSAGE FORM NEW ANIMAL DRUGS...) Severe infections should be supplemented by systemic therapy. (5) Prolonged administration of the drug... bacteria or fungi appear during therapy, appropriate measures should be taken. (6) Federal law restricts...

  14. A flexible super-capacitive solid-state power supply for miniature implantable medical devices.

    Science.gov (United States)

    Meng, Chuizhou; Gall, Oren Z; Irazoqui, Pedro P

    2013-12-01

    We present a high-energy local power supply based on a flexible and solid-state supercapacitor for miniature wireless implantable medical devices. Wireless radio-frequency (RF) powering recharges the supercapacitor through an antenna with an RF rectifier. A power management circuit for the super-capacitive system includes a boost converter to increase the breakdown voltage required for powering device circuits, and a parallel conventional capacitor as an intermediate power source to deliver current spikes during high current transients (e.g., wireless data transmission). The supercapacitor has an extremely high area capacitance of ~1.3 mF/mm(2), and is in the novel form of a 100 μm-thick thin film with the merit of mechanical flexibility and a tailorable size down to 1 mm(2) to meet various clinical dimension requirements. We experimentally demonstrate that after fully recharging the capacitor with an external RF powering source, the supercapacitor-based local power supply runs a full system for electromyogram (EMG) recording that consumes ~670 μW with wireless-data-transmission functionality for a period of ~1 s in the absence of additional RF powering. Since the quality of wireless powering for implantable devices is sensitive to the position of those devices within the RF electromagnetic field, this high-energy local power supply plays a crucial role in providing continuous and reliable power for medical device operations.

  15. 47 CFR 95.1121 - Specific requirements for wireless medical telemetry devices operating in the 1395-1400 and 1427...

    Science.gov (United States)

    2010-10-01

    ... wireless medical telemetry devices operating in the 1395-1400 and 1427-1432 MHz bands. Due to the critical... 47 Telecommunication 5 2010-10-01 2010-10-01 false Specific requirements for wireless medical telemetry devices operating in the 1395-1400 and 1427-1432 MHz bands. 95.1121 Section 95.1121...

  16. Virtual worlds are an innovative tool for medical device training in a simulated environment.

    Science.gov (United States)

    Patel, Vishal; Lee, Henry; Taylor, Dave; Aggarwal, Rajesh; Kinross, James; Darzi, Ara

    2012-01-01

    Medical infusion devices are an integral component within the delivery of healthcare management. The aim of this study was to develop a training simulation in the virtual world of Second Life for the management of adverse events associated with infusion devices. Forty nurses were subsequently recruited to participate within the simulation and assess its feasibility.

  17. In situ formation of antimicrobial silver nanoparticles and the impregnation of hydrophobic polycaprolactone matrix for antimicrobial medical device applications.

    Science.gov (United States)

    Tran, Phong A; Hocking, Dianna M; O'Connor, Andrea J

    2015-02-01

    Bacterial infection associated with medical devices remains a challenge to modern medicine as more patients are being implanted with medical devices that provide surfaces and environment for bacteria colonization. In particular, bacteria are commonly found to adhere more preferably to hydrophobic materials and many of which are used to make medical devices. Bacteria are also becoming increasingly resistant to common antibiotic treatments as a result of misuse and abuse of antibiotics. There is an urgent need to find alternatives to antibiotics in the prevention and treatment of device-associated infections world-wide. Silver nanoparticles have emerged as a promising non-drug antimicrobial agent which has shown effectiveness against a wide range of both Gram-negative and Gram-positive pathogen. However, for silver nanoparticles to be clinically useful, they must be properly incorporated into medical device materials whose wetting properties could be detrimental to not only the incorporation of the hydrophilic Ag nanoparticles but also the release of active Ag ions. This study aimed at impregnating the hydrophobic polycaprolactone (PCL) polymer, which is a FDA-approved polymeric medical device material, with hydrophilic silver nanoparticles. Furthermore, a novel approach was employed to uniformly, incorporate silver nanoparticles into the PCL matrix in situ and to improve the release of Ag ions from the matrix so as to enhance antimicrobial efficacy. Copyright © 2014. Published by Elsevier B.V.

  18. Reducing hospital noise: a review of medical device alarm management.

    Science.gov (United States)

    Konkani, Avinash; Oakley, Barbara; Bauld, Thomas J

    2012-01-01

    Increasing noise in hospital environments, especially in intensive care units (ICUs) and operating rooms (ORs), has created a formidable challenge for both patients and hospital staff. A major contributing factor for the increasing noise levels in these environments is the number of false alarms generated by medical devices. This study focuses on discovering best practices for reducing the number of false clinical alarms in order to increase patient safety and provide a quiet environment for both work and healing. The researchers reviewed Pub Med, Web of Knowledge and Google Scholar sources to obtain original journal research and review articles published through January 2012. This review includes 27 critically important journal articles that address different aspects of medical device alarms management, including the audibility, identification, urgency mapping, and response time of nursing staff and different solutions to such problems. With current technology, the easiest and most direct method for reducing false alarms is to individualize alarm settings for each patient's condition. Promoting an institutional culture change that emphasizes the importance of individualization of alarms is therefore an important goal. Future research should also focus on the development of smart alarms.

  19. 77 FR 26769 - Educational Forum on Medical Device Reporting, Complaint Files, and Recalls, Corrections, and...

    Science.gov (United States)

    2012-05-07

    ... Device Quality Systems Regulation (QSR) to the regulated industry, particularly small businesses. DATES... registration fee will be used to offset expenses of hosting the event including continental breakfast, lunch... interest in the topics discussed from small medical device manufacturers in the Dallas District area. This...

  20. Navigating conflicts of interest for the medical device entrepreneur.

    Science.gov (United States)

    Donovan, Aine; Kaplan, Aaron V

    2012-01-01

    The past fifty years has witnessed dramatic progress in the understanding and treatment of patients suffering from cardiovascular disease leading to symptomatic relief and impressive increases in longevity. These advances have been due in large part to the development, study and implementation of new technology. Within interventional cardiology in particular, these advances have been driven by the availability of new technology in the form of medical devices. Successful device development efforts require close collaboration among basic scientist, clinician-inventors/entrepreneurs, clinician-investigators and corporations. Though the role of the clinician is central to this process, these activities present important conflicts-of-interest (COIs). The purpose of this paper is to 1) characterize these conflicts, 2) provide a context from which to approach their management and 3) recommend management strategies. Copyright © 2012 Elsevier Inc. All rights reserved.