  1. Miniaturization of specimens for mechanical testing

    International Nuclear Information System (INIS)

    Harling, O.K.; Kohse, G.

    1987-01-01

    The development of mechanical property tests based on bending of a 3 mm diameter by (typically) 0.25 mm thick disk is described. Slow strain rate testing of such a disk is used to obtain tensile properties. Finite element computer modelling is used to extract yield stress values with accuracies of at least +- 10% of uniaxial tensile test values for a variety of materials. Analytical estimates of ductility from disk bend test values are possible for low-ductility materials. Work directed toward finite element calculations for ductility and ultimate tensile strength is also discussed. Preliminary data indicating the feasibility of high strain rate testing for estimation of ductile-to-brittle transition temperatures, and an example of the successful application of miniature bend testing in obtaining relative fatigue information are also presented. (author)

  2. Hydrogen embrittlement of titanium tested with fracture mechanics specimens

    International Nuclear Information System (INIS)

    Aho-Mantila, I.; Rahko, P.

    1990-11-01

    Titanium is one of the possible canister materials for spent nuclear fuel. The aim of this study is to determine whether the hydrogen embrittlement of titanium could be a possible deterioration mechanism of titanium canisters. This experimental study was preceded by a literature review and an experimental study on crack nucleation. Tests in this study were carried out with hydrogen charged fracture mechanics specimens. The studied hydrogen contents were as received, 100 ppm, 200 ppm, 500 ppm and 700 ppm and the types of the studied titanium were ASTM Grades 2 and 12. Test methods were slow tensile test (0.027 mm/h) and fatigue test (stress ratio 0.7 or 0.8 and frequency 5 Hz). According to the literature titanium may be embrittled by hydrogen at slow strain rates and cracking may occur under sustained load. In this study no evidence of hydrogen embrittlement was noticed in slow strain rate tension with bulk hydrogen contents up to 700 ppm. The fatigue tests of titanium Grades 2 and 12 containing 700 ppm hydrogen showed even slower crack growth compared to the as received condition. Very high hydrogen contents well in eccess of 700 ppm on the surface of titanium can, however, facilitate surface crack nucleation and crack growth, as shown in the previous study

  3. Special fracture mechanics specimens for multilayer plastic pipes testing

    Czech Academy of Sciences Publication Activity Database

    Hutař, Pavel; Šestáková, Lucie; Knésl, Zdeněk; Nezbedová, E.; Náhlík, Luboš

    2009-01-01

    Roč. 28, č. 8 (2009), s. 785-792 ISSN 0142-9418 R&D Projects: GA ČR GA106/09/0279; GA ČR GC101/09/J027 Institutional research plan: CEZ:AV0Z20410507 Keywords : Multilayer plastic pipes * C-type specimen * K-calibration * Fracture toughness * Slow crack growth * Non-homogenous specimens Subject RIV: JL - Material s Fatigue, Friction Mechanics Impact factor: 1.667, year: 2009

  4. Analysis of the applicability of fracture mechanics on the basis of large scale specimen testing

    International Nuclear Information System (INIS)

    Brumovsky, M.; Polachova, H.; Sulc, J.; Anikovskij, V.; Dragunov, Y.; Rivkin, E.; Filatov, V.

    1988-01-01

    The verification is dealt with of fracture mechanics calculations for WWER reactor pressure vessels by large scale model testing performed on the large testing machine ZZ 8000 (maximum load of 80 MN) in the Skoda Concern. The results of testing a large set of large scale test specimens with surface crack-type defects are presented. The nominal thickness of the specimens was 150 mm with defect depths between 15 and 100 mm, the testing temperature varying between -30 and +80 degC (i.e., in the temperature interval of T ko ±50 degC). Specimens with a scale of 1:8 and 1:12 were also tested, as well as standard (CT and TPB) specimens. Comparisons of results of testing and calculations suggest some conservatism of calculations (especially for small defects) based on Linear Elastic Fracture Mechanics, according to the Nuclear Reactor Pressure Vessel Codes which use the fracture mechanics values from J IC testing. On the basis of large scale tests the ''Defect Analysis Diagram'' was constructed and recommended for brittle fracture assessment of reactor pressure vessels. (author). 7 figs., 2 tabs., 3 refs

  5. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    DEFF Research Database (Denmark)

    Sørensen, Bent F.; Jørgensen, K.; Jacobsen, T.K.

    2004-01-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratiobetween the two applied moments, the full mode...... glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre bridging, eventually reaching asteady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement....

  6. Grips for testing of electrical characteristics of a specimen under a mechanical load

    Science.gov (United States)

    Briggs, Timothy; Loyola, Bryan

    2018-04-24

    Various technologies to facilitate coupled electrical and mechanical measurement of conductive materials are disclosed herein. A gripping device simultaneously holds a specimen in place and causes contact to be made between the specimen and a plurality of electrodes connected to an electrical measuring device. An electrical characteristic of the specimen is then measured while a mechanical load is applied to the specimen, and a relationship between the mechanical load and changes in the electrical characteristic can be identified.

  7. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, B.F.; Joergensen, K.; Oestergaard, R.C. [Risoe National Lab., Materials Dept., Roskilde (Denmark); Jacobsen, T.K. [LM Glasfiber A/S, Lunderskov (Denmark)

    2004-03-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratio between the two applied moments, the full mode mixity range from pure mode I to pure mode II can be generated for the same specimen geometry. The specimen allows stable crack growth. In case of large scale crack bridging, mixed mode cohesive laws can be obtained by a J integral based approach. As a preliminary example, fracture of adhesive joints between two glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre cross over bridging, eventually reaching a steady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement. Cohesive stresses were determined by a J integral approach. The deducted shear stress was found to be relative high ({approx} = 20 MPa) in comparison with the normal stress ({approx} = 1 MPa). (au)

  8. Examination of cadmium safety rod thermal test specimens and failure mechanism evaluation

    International Nuclear Information System (INIS)

    Thomas, J.K.; Peacock, H.B.; Iyer, N.C.

    1992-01-01

    The reactor safety rods may be subjected to high temperatures due to gamma heating after the core coolant level has dropped during the ECS phase of a hypothetical LOCA event. Accordingly, an experimental cadmium safety rod testing subtask was established as part of a task to address the response of reactor core components to this accident. Companion reports describe the experiments and a structural evaluation (finite element analysis) of the safety rod. This report deals primarily with the examination of the test specimens, evaluation of possible failure mechanisms, and confirmatory separate effects experiments. It is concluded that the failures observed in the cadmium safety rod thermal tests which occurred at low temperature (T 800 degrees C) with fast thermal ramp rates are concluded to be mechanical in nature without significant environmental degradation. Based on these tests, tasks were initiated to design and manufacture B 4 C safety rods to replace the cadmium safety rods. The B 4 C safety rods have been manufactured at this time and it is currently planned to charge them to the reactor in the near future. 60 refs

  9. Elastic-plastic analysis of fracture mechanics test specimens. Part 2

    International Nuclear Information System (INIS)

    Talja, H.; Wallin, K.

    1984-12-01

    This is second part of the report of the research program 'Comparisons between computational and experimental elastic-plastic results' started at the Technical Research Centre of Finland in 1981. The first part of the research program was reported earlier and contained a two dimensional linear elastic finite element analysis of four specimen geometries (CT, RCT, ASTM-3P and Charpy-V) and testing and elastic-plastic analysis of the specimen (EGF71; 1TCT, material A 542). In this report the second part of the program containing the testing and 2-D elastic-plastic analyses of five specimens is described. The four specimen geometries mentioned above and two different materials (stainless steel AISI 304 and ferrite pressure vessel steel A533B) are considered. The following comparisons are presented in the report: load vs. load displacement curves, J-integral, crack opening displacement (COD), J vs. COD and the size of the plastic zone. The agreement between the computational and experimental results is quite good. Complete agreement can be achieved only with 3-dimensional calculation models. (author)

  10. Study of Mechanical Characterization of Ceramic Specimens from a Brazilian Test Adaptation

    Directory of Open Access Journals (Sweden)

    Iglesias, I.

    2011-09-01

    Full Text Available The Brazilian Test is easy to perform and its result is the tensile strength of the material provided certain ratios are fulfilled between the diameter of the sample, the load bearing width and the characteristic length of the material. In this paper we present experimental results obtained from 8 mm-thick ceramic cylinders whose diameter was 40 mm in length. The cylinders were obtained from a standard type of clay by pressing and subsequent baking at 900 ºC. We made a complete mechanical characterization of the material, which included obtaining fracture properties, and a numerical simulation of the Brazilian test based on the cohesive crack model. Numerical results confirm that the size and boundary conditions chosen for the test are adequate to get the actual tensile strength of construction ceramics, which prove that this type of test is useful to compare the strength of several types of construction ceramics in a simple and convenient way. Besides, it requires a very small amount of material to prepare the specimen

    El ensayo de compresión diametral (ensayo Brasileño es un ensayo fácil de realizar que da como resultado la resistencia a tracción del material siempre que se cumplan una serie de proporciones entre el diámetro de la probeta, el ancho de reparto de la carga y la longitud característica del material. En este artículo presentamos unos resultados sobre probetas cerámicas cilíndricas de 40 mm de diámetro y 8 mm de espesor, elaboradas por prensado a partir de arcillas comunes y cocidas a 900 ºC. Se ha realizado una caracterización mecánica de dichas probetas, que incluye sus propiedades en fractura, y una simulación numérica del ensayo brasileño basada en el modelo de fisura cohesiva. Los resultados numéricos confirman que el tamaño y condiciones de contorno elegidos para el ensayo son apropiados para obtener la resistencia a tracción de este tipo de material cerámico con lo que este ensayo se convierte en

  11. Splitting tests on rock specimens

    Energy Technology Data Exchange (ETDEWEB)

    Davies, J D; Stagg, K G

    1970-01-01

    Splitting tests are described for a square-section sandstone specimens line loaded through steel or timber packings on the top face and supported on the bottom face either on similar packings (type A specimen) or directly on the lower platen plate of the testing machine (type B specimens). The stress distribution across the vertical central plane and the horizontal central plane were determined from a linear elastic finite element analysis for both types. Two solutions were obtained for the type B specimen: one assuming no friction between the base of the specimen and the platen plate and the other assuming no relative slip between the surfaces. Vertical and horizontal strains were measured at the center of the specimens for all loads up to failure.

  12. Technology development on production of test specimens from irradiated capsule outer-tube and mechanical evaluation test of stainless steel with high dose carried out by the technology

    International Nuclear Information System (INIS)

    Hayashi, Koji; Shibata, Akira; Iwamatsu, Shigemi; Sozawa, Shizuo; Takada, Fumiki; Ohmi, Masao; Nakagawa, Tetsuya

    2008-03-01

    The irradiation capsule 74M-52J was irradiated during total 136 cycles at reactor core of JMTR and the maximum neutron dose reached on 3.9x10 26 n/m 2 at the capsule outer-tube made of a type 304 stainless steel. In order to produce mechanical test specimens from the outer-tube, a punching technique was developed as a simple remote-handling method in a hot-cell. From comparison between the punching and the mechanical cutting methods, it was clarified that the punching technique was applicable to practical use. Moreover, an evaluation test of mechanical properties using specimens sampled from the 74M-52 was performed with in-water high temperature condition, less than 288degC. The result shows that the residual elongation is 18% at 150degC and 13% at 288degC. It was confirmed that the type 304 stainless steel irradiated up to such high dose shows enough ductility. (author)

  13. Conclusions regarding fracture mechanics testing and evaluation of small specimens - As evidenced by the finnish contribution to the IAEA CRP3 programme

    Energy Technology Data Exchange (ETDEWEB)

    Wallin, K; Valo, M; Rintamaa, R; Torronen, K [Technical Research Centre of Finland, Espoo (Finland); Ahlstrand, R [Imatran Voima Oy (IVO), Helsinki (Finland)

    1994-12-31

    An extensive mechanical property evaluation has been carried out on various specimens (a Japanese steel plate (JRQ), a French forging material (FFA) and a Japanese forging material (JFL)) in the as-received and irradiated conditions. The mechanical properties measured at different temperatures include Charpy-V notch and instrumented pre-cracked Charpy data and static and dynamic elastic-plastic fracture toughness based on the J-integral, with various specimen size and geometry. Test analysis lead to conclusions regarding the use of small specimen fracture mechanical tests for investigating irradiation effects: CVN{sub pc} and RCT type specimens are suitable for determining the materials fracture toughness even in the ductile/brittle transition region provided the elastic-plastic parameter K{sub JC} is applied together with a statistical size correction. These two specimen types yield equivalent results for the fracture toughness transition shift. Charpy-V appears not to be suitable for estimating the static fracture toughness transition shift. 8 refs., 11 figs.

  14. Two-parameter fracture mechanical analysis of a near-crack-tip stress field in wedge splitting test specimens

    Czech Academy of Sciences Publication Activity Database

    Seitl, Stanislav; Veselý, V.; Řoutil, L.

    2011-01-01

    Roč. 89, 21-22 (2011), s. 1852-1858 ISSN 0045-7949. [International Conference on Civil, Structural and Enviromental Engineering Computing /12./. Funchal, Madeira, 01.09.2009-04.09.2009] Institutional research plan: CEZ:AV0Z20410507 Keywords : Wedge splitting test * Stress intensity factor * T-stress * Numerical simulation * Direct method Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 1.874, year: 2011

  15. Specimen size effects in Charpy impact testing

    International Nuclear Information System (INIS)

    Alexander, D.J.; Klueh, R.L.

    1989-01-01

    Full-size , half-size, and third-size specimens from several different steels have been tested as part of an ongoing alloy development program. The smaller specimens permit more specimens to be made from small trail heats and are much more efficient for irradiation experiments. The results of several comparisons between the different specimen sizes have shown that the smaller specimens show qualitatively similar behavior to large specimens, although the upper-shelf energy level and ductile-to-ductile transition temperature are reduced. The upper-shelf energy levels from different specimen sizes can be compared by using a simple volume normalization method. The effect of specimen size and geometry on the ductile-to-ductile transition temperature is more difficult to predict, although the available data suggest a simple shift in the transition temperature due to specimen size changes.The relatively shallower notch used in smaller specimens alters the deformation pattern, and permits yielding to spread back to the notched surface as well as through to the back. This reduces the constraint and the peak stresses, and thus the initiation of cleavage is more difficult. A better understanding of the stress and strain distributions is needed. 19 refs., 3 figs., 3 tabs

  16. Thermal property testing technique on micro specimen

    International Nuclear Information System (INIS)

    Baba, Tetsuya; Kishimoto, Isao; Taketoshi, Naoyuki

    2000-01-01

    This study aims at establishment of further development on some testing techniques on the nuclear advanced basic research accumulated by the National Research Laboratory of Metrology for ten years. For this purpose, a technology to test heat diffusion ratio and specific heat capacity of less than 3 mm in diameter and 1 mm in thickness of micro specimen and technology to test heat diffusion ratio at micro area of less than 1 mm in area along cross section of less than 10 mm in diameter of column specimen were developed to contribute to common basic technology supporting the nuclear power field. As a result, as an element technology to test heat diffusion ratio and specific heat capacity of the micro specimen, a specimen holding technique stably to hold a micro specimen with 3 mm in diameter could be developed. And, for testing the specific heat capacity by using the laser flush differential calorimetry, a technique to hold two specimen of 5 mm in diameter at their proximities was also developed. In addition, by promoting development of thermal property data base capable of storing thermal property data obtained in this study and with excellent workability in this 1998 fiscal year a data in/out-put program with graphical user interface could be prepared. (G.K.)

  17. Instrumented impact testing machine with reduced specimen oscillation effects

    International Nuclear Information System (INIS)

    Rintamaa, R.; Rahka, K.; Wallin, K.

    1984-07-01

    Owing to small and inexpensive specimens the Charpy impact test is widely used in quality control and alloy development. Limitations in power reactor survellance capsules it is also widely used for safety analysis purposes. Instrumenting the tup and computerizing data acquisition, makes dynamic fracture mechanics data measurement possible and convenient. However, the dynamic effects (inertia forces, specimen oscillations) in the impact test cause inaccuracies in the recorded load-time diagram and hence diminish the reliability of the calculated dynamic fracture mechanics parameters. To decrease inaccuracies a new pendulum type of instrumented impact test apparatus has been developed and constructed in the Metals Laboratory of the Technical Research Centre of Finland. This tester is based on a new principle involving inverted test geometry. The purpose of the geometry inversion is to reduce inertia load and specimen oscillation effects. Further, the new impact tester has some other novel features: e.g. the available initia impact energy is about double compared to the conventional standard (300 J) impact tester allowing the use of larger (10 x 20 x 110 mm) bend specimens than normal Charpy specimens. Also, the rotation asix in the three point bending is nearly stationary making COD-measurements possible. An experimental test series is described in which the inertia effects and specimen oscillations are compared in the conventional and new impact tester utilizing Charpy V-notch specimens. Comparison of the two test geometries is also made with the aid of an analytical model using finite element method (FEM) analysis. (author)

  18. Small specimen technique for assessing mechanical properties of metallic components

    Energy Technology Data Exchange (ETDEWEB)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E., E-mail: rmlobo@ipen.br, E-mail: morcelliae@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  19. Small specimen technique for assessing mechanical properties of metallic components

    International Nuclear Information System (INIS)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E.

    2017-01-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  20. Some recent innovations in small specimen testing

    International Nuclear Information System (INIS)

    Odette, G.R.; He, M.; Gragg, D.; Klingensmith, D.; Lucas, G.E.

    2002-01-01

    New innovative small specimen test techniques are described. Finite element simulations show that combinations of cone indentation pile-up geometry and load-penetration depth relations can be used to determine both the yield stress and strain-hardening behavior of a material. Techniques for pre-cracking and testing sub-miniaturized fracture toughness bend bars, with dimensions of 1.65x1.65x9 mm 3 , or less, are described. The corresponding toughness-temperature curves have a very steep transition slope, primarily due to rapid loss of constraint, which has advantages in some experiments to characterize the effects of specified irradiation variables. As one example of using composite specimens, an approach to evaluating helium effects is proposed, involving diffusion bonding small wires of a 54 Fe-based ferritic-martensitic alloy to a surrounding fracture specimen composed of an elemental Fe-based alloy. Finally, we briefly outline some potential approaches to multipurpose specimens and test automation

  1. Thermal endurance tests on silicone rubber specimens

    International Nuclear Information System (INIS)

    Warburton, C.

    1977-07-01

    Thermal endurance tests have been performed on a range of silicone rubber specimens at temperature above 300 0 C. It is suggested that the rubber mix A2426, the compound from which Wylfa sealing rings are manufactured, will fail at temperatures above 300 0 C within weeks. Hardness measurements show that this particular rubber performs in a similar manner to Walker's S.I.L./60. (author)

  2. Specimen alignment in an axial tensile test of thin films using direct imaging and its influence on the mechanical properties of BeCu

    International Nuclear Information System (INIS)

    Kang, Dong-Joong; Park, Jun-Hyub; Shin, Myung-Soo; Ha, Jong-Eun; Lee, Hak-Joo

    2010-01-01

    This paper proposes a new system for verification of the alignment of loading fixtures and test specimens during tensile testing of thin film with a micrometer size through direct imaging. The novel and reliable image recognition system to evaluate the misalignment between the load train and the specimen axes during tensile test of thin film was developed using digital image processing technology with CCD. The decision of whether alignment of the tensile specimen is acceptable or not is based on a probabilistic analysis through the edge feature extraction of digital imaging. In order to verify the performance of the proposed system and investigate the effect of the misalignment of the specimen on tensile properties, the tensile tests were performed as displacement control in air and at room temperature for metal thin film, the beryllium copper (BeCu) alloys. In the case of the metal thin films, bending stresses caused by misalignment are insignificant because the films are easily bent during tensile tests to eliminate the bending stresses. And it was observed that little effects and scatters on tensile properties occur by stress gradient caused by twisting at in-plane misalignment, and the effects and scatters on tensile properties are insignificant at out-of-plane misalignment, in the case of the BeCu thin film.

  3. Corrosion testing of uranium silicide fuel specimens

    International Nuclear Information System (INIS)

    Bourns, W.T.

    1968-09-01

    U 3 Si is the most promising high density natural uranium fuel for water-cooled power reactors. Power reactors fuelled with this material are expected to produce cheaper electricity than those fuelled with uranium dioxide. Corrosion tests in 300 o C water preceded extensive in-reactor performance tests of fuel elements and bundles. Proper heat-treatment of U-3.9 wt% Si gives a U 3 5i specimen which corrodes at less than 2 mg/cm 2 h in 300 o C water. This is an order of magnitude lower than the maximum corrosion rate tolerable in a water-cooled reactor. U 3 Si in a defected unbonded Zircaloy-2 sheath showed only a slow uniform sheath expansion in 300 o C water. All tests were done under isothermal conditions in an out-reactor loop. (author)

  4. Corrosion testing of uranium silicide fuel specimens

    Energy Technology Data Exchange (ETDEWEB)

    Bourns, W T

    1968-09-15

    U{sub 3}Si is the most promising high density natural uranium fuel for water-cooled power reactors. Power reactors fuelled with this material are expected to produce cheaper electricity than those fuelled with uranium dioxide. Corrosion tests in 300{sup o}C water preceded extensive in-reactor performance tests of fuel elements and bundles. Proper heat-treatment of U-3.9 wt% Si gives a U{sub 3}5i specimen which corrodes at less than 2 mg/cm{sup 2} h in 300{sup o}C water. This is an order of magnitude lower than the maximum corrosion rate tolerable in a water-cooled reactor. U{sub 3}Si in a defected unbonded Zircaloy-2 sheath showed only a slow uniform sheath expansion in 300{sup o}C water. All tests were done under isothermal conditions in an out-reactor loop. (author)

  5. Single specimen fracture toughness determination procedure using instrumented impact test

    International Nuclear Information System (INIS)

    Rintamaa, R.

    1993-04-01

    In the study a new single specimen test method and testing facility for evaluating dynamic fracture toughness has been developed. The method is based on the application of a new pendulum type instrumented impact tester equipped with and optical crack mouth opening displacement (COD) extensometer. The fracture toughness measurement technique uses the Double Displacement Ratio (DDR) method, which is based on the assumption that the specimen is deformed as two rigid arms that rotate around an apparent centre of rotation. This apparent moves as the crack grows, and the ratio of COD versus specimen displacement changes. As a consequence the onset ductile crack initiation can be detected on the load-displacement curve. Thus, an energy-based fracture toughness can be calculated. In addition the testing apparatus can use specimens with the Double ligament size as compared with the standard Charpy specimen which makes the impact testing more appropriate from the fracture mechanics point of view. The novel features of the testing facility and the feasibility of the new DDR method has been verified by performing an extensive experimental and analytical study. (99 refs., 91 figs., 27 tabs.)

  6. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  7. Fracture toughness evaluation of Eurofer'97 by testing small specimens

    International Nuclear Information System (INIS)

    Serrano, M.; Fernandez, P.; Lapena, J.

    2006-01-01

    The Eurofer'97 is the structural reference material that will be tested in the ITER modules. Its metallurgical properties have been well characterized during the last years. However, more investigations related with the fracture toughness of this material are necessary because this property is one of the most important to design structural components and to study their integrity assessment. In the case of structural materials for fusion reactor the small specimen technology (SSTT) are being actively developed to investigate the fracture toughness among other mechanical properties. The use of small specimens is due to the small available irradiation volume of IFMIF and also due to the high fluence expected in the fusion reactor. The aim of this paper is to determine the fracture toughness of the Eurofer'97 steel by testing small specimens of different geometry in the ductile to brittle transition region, with the application of the Master Curve methodology, and to evaluate this method to assess the decrease in fracture toughness due to neutron irradiation. The tests and data analysis have been performed following the Master Curve approach included in the ASTM Standard E1921-05. Specimen size effect and comparison of the fracture toughness results with data available in the literature are also considered. (author)

  8. Use of miniature tensile specimen and video extensometer for measurement of mechanical properties

    International Nuclear Information System (INIS)

    Kumar, Kundan; Pooleery, Arun; Madhusoodanan, K.

    2014-08-01

    Miniaturisation of the tensile test specimen below the sub-size level poses various challenges, such as conformity of specimen to various acceptance criteria as per standard test specimen, aspect ratio, minimum number of grains required in a gauge cross-section, fabrication for uniformity in metrological values, etc. Apart from these, measurement of strain over a very limited available space on the test specimen is another practical challenge. Despite these limitations, miniature specimen testing is increasingly being used worldwide these days. The driving forces behind increasing use of miniature test techniques are new material development, assuring fitness of component after in-service-inspection, low dose of radiation exposure due to smaller dimensions of test specimens etc. However, the evaluation of mechanical properties from a miniature tensile test has a greater advantage over the other miniature novel test techniques, such as small punch test, ABI, miniature fatigue and impact tests etc., as it is a direct method of measurement of mechanical properties. This report covers various aspects of miniature tensile test methodologies, which include geometrical design of specimen having gauge length of 3-5 mm, fabrication, development of special fixtures for gripping the test specimens, and use of optical method for strain measurement. The geometrical design of the specimen and its behaviour over application of tensile load has been established using FEM analysis. A good agreement between conventional and miniature test results exemplifies the potential of the miniature tensile test technique. (author)

  9. 46 CFR 57.06-4 - Production testing specimen requirements.

    Science.gov (United States)

    2010-10-01

    ... WELDING AND BRAZING Production Tests § 57.06-4 Production testing specimen requirements. (a) For test... 46 Shipping 2 2010-10-01 2010-10-01 false Production testing specimen requirements. 57.06-4... to welding shall not throw the finished test plate out of line by an angle of over 5°. (c) Where the...

  10. Fracture mechanics characterisation of medium-size adhesive joint specimens

    DEFF Research Database (Denmark)

    Sørensen, Bent F.; Jacobsen, T.K.

    2004-01-01

    Medium-size specimens (glass-fibre beams bonded together by an adhesive layer were tested in four point bending to determine their load carrying capacity. Specimens having different thickness were tested. Except for onespecimen, the cracking occurred as cracking...... along the adhesive layer; initially cracking occurred along the adhesive/laminate interface, but after some crack extension the cracking took place inside the laminate (for one specimen the later part of thecracking occurred unstably along the adhesive/ laminate interface). Crack bridging by fibres...

  11. Biaxial Testing of 2195 Aluminum Lithium Alloy Using Cruciform Specimens

    Science.gov (United States)

    Johnston, W. M.; Pollock, W. D.; Dawicke, D. S.; Wagner, John A. (Technical Monitor)

    2002-01-01

    A cruciform biaxial test specimen was used to test the effect of biaxial load on the yield of aluminum-lithium alloy 2195. Fifteen cruciform specimens were tested from 2 thicknesses of 2195-T8 plate, 0.45 in. and 1.75 in. These results were compared to the results from uniaxial tensile tests of the same alloy, and cruciform biaxial tests of aluminum alloy 2219-T87.

  12. Uniaxial compression tests on diesel contaminated frozen silty soil specimens

    International Nuclear Information System (INIS)

    Chenaf, D.; Stampli, N.; Bathurst, R.; Chapuis, R.P.

    1999-01-01

    Results of a uniaxial, unconfined compression test on artificial diesel-contaminated and uncontaminated frozen silty soils are discussed. The testing program involved 59 specimens. The results show that for the same fluid content, diesel contamination reduced the strength of the frozen specimens by increasing the unfrozen water content. For example, in specimens containing 50 per cent diesel oil of the fluid content by weight the maximum strength was reduced by 95 per cent compared to the strength of an uncontaminated specimen. Diesel contamination was also shown to contribute to the slippage between soil particles by acting as a lubricant, thus accelerating the loss of compressive strength.13 refs., 18 figs

  13. Damage modeling in Small Punch Test specimens

    DEFF Research Database (Denmark)

    Martínez Pañeda, Emilio; Cuesta, I.I.; Peñuelas, I.

    2016-01-01

    . Furthermore,Gurson-Tvergaard-Needleman model predictions from a top-down approach are employed to gain insightinto the mechanisms governing crack initiation and subsequent propagation in small punch experiments.An accurate assessment of micromechanical toughness parameters from the SPT...

  14. Post-deformation examination of specimens subjected to SCC testing

    Energy Technology Data Exchange (ETDEWEB)

    Gussev, Maxim N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Field, Kevin G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Busby, Jeremy T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Leonard, Keith J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-09-01

    This report details the results of post-radiation and post-deformation characterizations performed during FY 2015–FY 2016 on a subset of specimens that had previously been irradiated at high displacement per atom (dpa) damage doses. The specimens, made of commercial austenitic stainless steels and alloys, were subjected to stress-corrosion cracking tests (constant extension rate testing and crack growth testing) at the University of Michigan under conditions typical of nuclear power plants. After testing, the specimens were returned to Oak Ridge National Laboratory (ORNL) for further analysis and evaluation.

  15. Fabrication and testing of prestressed composite rotor blade spar specimens

    Science.gov (United States)

    Gleich, D.

    1974-01-01

    Prestressed composite spar specimens were fabricated and evaluated by crack propagation and ballistic penetration tests. The crack propagation tests on flawed specimens showed that the prestressed composite spar construction significantly suppresses crack growth. Damage from three high velocity 30 caliber projectile hits was confined to three small holes in the ballistic test specimen. No fragmentation or crack propagation was observed indicating good ballistic damage resistance. Rotor attachment approaches and improved structural performance configurations were identified. Design theory was verified by tests. The prestressed composite spar configuration consisted of a compressively prestressed high strength ARDEFORM 301 stainless steel liner overwrapped with pretensioned S-994 fiberglass.

  16. Standard practice for preparing, cleaning, and evaluating corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers suggested procedures for preparing bare, solid metal specimens for tests, for removing corrosion products after the test has been completed, and for evaluating the corrosion damage that has occurred. Emphasis is placed on procedures related to the evaluation of corrosion by mass loss and pitting measurements. (Warning—In many cases the corrosion product on the reactive metals titanium and zirconium is a hard and tightly bonded oxide that defies removal by chemical or ordinary mechanical means. In many such cases, corrosion rates are established by mass gain rather than mass loss.) 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 1 and 7.2.

  17. Improved PID control for triaxial testing liquefied specimen

    DEFF Research Database (Denmark)

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    Using a frictionless triaxial apparatus, sand specimens can be tested at relatively high axial strains, even while liquefying. However, liquefying specimens have extremely nonlinear stiffness, thus standard PID control does not perform well. To maintain control over applied loads, the PID...... controller was modified to adapt to disturbed soil states. The proposed methods expand the scope of testing towards options which are otherwise inaccessible by triaxial testing....

  18. Tensile-Creep Test Specimen Preparation Practices of Surface Support Liners

    Science.gov (United States)

    Guner, Dogukan; Ozturk, Hasan

    2017-12-01

    Ground support has always been considered as a challenging issue in all underground operations. Many forms of support systems and supporting techniques are available in the mining/tunnelling industry. In the last two decades, a new polymer based material, Thin Spray-on Liner (TSL), has attained a place in the market as an alternative to the current areal ground support systems. Although TSL provides numerous merits and has different application purposes, the knowledge on mechanical properties and performance of this material is still limited. In laboratory studies, since tensile rupture is the most commonly observed failure mechanism in field applications, researchers have generally studied the tensile testing of TSLs with modification of American Society for Testing and Materials (ASTM) D-638 standards. For tensile creep testing, specimen preparation process also follows the ASTM standards. Two different specimen dimension types (Type I, Type IV) are widely preferred in TSL tensile testing that conform to the related standards. Moreover, molding and die cutting are commonly used specimen preparation techniques. In literature, there is a great variability of test results due to the difference in specimen preparation techniques and practices. In this study, a ductile TSL product was tested in order to investigate the effect of both specimen preparation techniques and specimen dimensions under 7-day curing time. As a result, ultimate tensile strength, tensile yield strength, tensile modulus, and elongation at break values were obtained for 4 different test series. It is concluded that Type IV specimens have higher strength values compared to Type I specimens and moulded specimens have lower results than that of prepared by using die cutter. Moreover, specimens prepared by molding techniques have scattered test results. Type IV specimens prepared by die cutter technique are suggested for preparation of tensile test and Type I specimens prepared by die cutter technique

  19. A test specimen for characterizing the fracture energy of interfaces in composites

    International Nuclear Information System (INIS)

    Shaw, L.; Abbaschian, R.

    1993-01-01

    A sandwich-type chevron-notched specimen, which has a phase angle of loading near zero, is proposed to measure interfacial fracture energy arising mainly from chemical bonding. With the specimen configuration of this kind, the advantages from both sandwich test specimens and chevron-notched specimens can be combined to provide an easy and accurate test for the measurement of interfacial fracture energy. The validity of the specimen has been analyzed in terms of the mechanics of sandwich-type specimens and chevron-notched specimens, and demonstrated using the Al 2 O 3 /Nb bimaterial system. The results show that for a phase angle of loading around -7 degrees the Al 2 O 3 /Nb interface has a fracture energy of 9.3 ± 0.2 J/m 2 . 39 refs

  20. Development of piezoelectric ceramics driven fatigue testing machine for small specimens

    International Nuclear Information System (INIS)

    Saito, S.; Kikuchi, K.; Onishi, Y.; Nishino, T.

    2002-01-01

    A new fatigue testing machine with piezoelectric ceramics actuators was developed and a prototype was manufactured for high-cycle fatigue tests with small specimens. The machine has a simple mechanism and is compact. These features make it easy to set up and to maintain the machine in a hot cell. The excitation of the actuator can be transmitted to the specimen using a lever-type testing jig. More than 100 μm of displacement could be prescribed precisely to the specimen at a frequency of 50 Hz. This was sufficient performance for high-cycle bend fatigue tests on specimens irradiated at the SINQ target in Paul Scherrer Institute. The relationship of a displacement applied to the specimen and the strain of the necking part were obtained by experimental methods and by finite element method (FEM) calculations. Both results showed good agreement. This fact makes it possible to evaluate the strain of irradiated specimens by FEM simulations

  1. Tension test system for irradiated small specimens operated by remote control

    International Nuclear Information System (INIS)

    Okada, Akira

    1993-01-01

    A robot-based tension test system has been developed to aid in the mechanical testing of highly radioactive specimens. This system reduces radiation hazards from specimens and allows for the uniform precision of testing results independent of experimenters' skills. The robot system is designed to accommodate a miniaturized tension specimen with a gage section 5.5 by 1.2 mm, with a total length and width of 12.5 and 2.3 mm, respectively, and thickness of about 0.2 mm. The system is composed of a manipulating robot, a vibrational-type specimen feeder, a rotating-type specimen tray, a specimen observation system, a simulated tension text fixture, and a microcomputer for controlling the system. This system accomplishes specimen arrangement in the specimen tray, specimen transportation and loading to the test fixture and testing, and removal of the broken specimen from the fixture. These procedures are performed quickly, safely, and with uniform testing precision by computer control remotely by an unskilled experimenter

  2. 46 CFR 54.05-5 - Toughness test specimens.

    Science.gov (United States)

    2010-10-01

    ... shown in Figure 4 of the specification. Special attention is drawn to the fact that the Charpy Keyhole....090-inch. In preparing weld specimens for dropweight testing, weld reinforcement shall be ground flush...

  3. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-01

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified. PMID:29337867

  4. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens.

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-16

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified.

  5. Influence of thermal conditioning media on Charpy specimen test temperature

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Swain, R.L.; Berggren, R.G.

    1989-01-01

    The Charpy V-notch (CVN) impact test is used extensively for determining the toughness of structural materials. Research programs in many technologies concerned with structural integrity perform such testing to obtain Charpy energy vs temperature curves. American Society for Testing and Materials Method E 23 includes rather strict requirements regarding determination and control of specimen test temperature. It specifies minimum soaking times dependent on the use of liquids or gases as the medium for thermally conditioning the specimen. The method also requires that impact of the specimen occur within 5 s removal from the conditioning medium. It does not, however, provide guidance regarding choice of conditioning media. This investigation was primarily conducted to investigate the changes in specimen temperature which occur when water is used for thermal conditioning. A standard CVN impact specimen of low-alloy steel was instrumented with surface-mounted and embedded thermocouples. Dependent on the media used, the specimen was heated or cooled to selected temperatures in the range -100 to 100 degree C using cold nitrogen gas, heated air, acetone and dry ice, methanol and dry ice, heated oil, or heated water. After temperature stabilization, the specimen was removed from the conditioning medium while the temperatures were recorded four times per second from all thermocouples using a data acquisition system and a computer. The results show that evaporative cooling causes significant changes in the specimen temperatures when water is used for conditioning. Conditioning in the other media did not result in such significant changes. The results demonstrate that, even within the guidelines of E 23, significant test temperature changes can occur which may substantially affect the Charpy impact test results if water is used for temperature conditioning. 7 refs., 11 figs

  6. Mechanical characteristics of historic mortars from tests on small-sample non-standard on small-sample non-standard specimens

    Czech Academy of Sciences Publication Activity Database

    Drdácký, Miloš; Slížková, Zuzana

    2008-01-01

    Roč. 17, č. 1 (2008), s. 20-29 ISSN 1407-7353 R&D Projects: GA ČR(CZ) GA103/06/1609 Institutional research plan: CEZ:AV0Z20710524 Keywords : small-sample non-standard testing * lime * historic mortar Subject RIV: AL - Art, Architecture, Cultural Heritage

  7. Progress Report on Alloy 617 Notched Specimen Testing

    Energy Technology Data Exchange (ETDEWEB)

    McMurtrey, Michael David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wright, Richard Neil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lillo, Thomas Martin [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-08-01

    Creep behavior of Alloy 617 has been extensively characterized to support the development of a draft Code Case to qualify Alloy 617 in Section III division 5 of the ASME Boiler and Pressure Vessel Code. This will allow use of Alloy 617 in construction of nuclear reactor components at elevated temperatures and longer periods of time (up to 950°C and 100,000 hours). Prior to actual use, additional concerns not considered in the ASME code need to be addressed. Code Cases are based largely on uniaxial testing of smooth gage specimens. In service conditions, components will generally be under multi axial loading. There is also the concern of the behavior at discontinuities, such as threaded components. To address the concerns of multi axial creep behavior and at geometric discontinuities, notched specimens have been designed to create conditions representative of the states that service components experience. Two general notch geometries have been used for these series of tests: U notch and V notch specimens. The notches produce a tri axial stress state, though not uniform across the specimen. Characterization of the creep behavior of the U notch specimens and the creep rupture behavior of the V notch specimens provides a good approximation of the behavior expected of actual components. Preliminary testing and analysis have been completed and are reported in this document. This includes results from V notch specimens tested at 900°C and 800°C. Failure occurred in the smooth gage section of the specimen rather than at the root of the notch, though some damage was present at the root of the notch, where initial stress was highest. This indicates notch strengthening behavior in this material at these temperatures.

  8. A mechanical microcompressor for high resolution imaging of motile specimens

    OpenAIRE

    Zinskie, Jessica A.; Shribak, Michael; Bruist, Michael F.; Aufderheide, Karl J.; Janetopoulos, Chris

    2015-01-01

    In order to obtain fine details in 3 dimensions (3D) over time, it is critical for motile biological specimens to be appropriately immobilized. Of the many immobilization options available, the mechanical microcompressor offers many benefits. Our device, previously described, achieves gentle flattening of a cell, allowing us to image finely detailed structures of numerous organelles and physiological processes in living cells. We have imaged protozoa and other small metazoans using differenti...

  9. Strip specimen tests for pipeline materials and girth welds

    Energy Technology Data Exchange (ETDEWEB)

    Mohr, William C. [Edison Welding Institute (EWI), Columbus, Ohio (United States)

    2009-07-01

    Strip specimen testing of pipeline materials has been widely applied as a method of getting data relevant to the performance of pipelines under axial direction loading. Comparisons of strip specimen against smaller standard tests (round tensile bar, fracture toughness specimens, polished round bars) and against full-scale or large-scale testing will be explored. Data from early-generation pipe welds from the 1920's to the 1940's to the most recent materials for offshore reeled pipe will be used for examples. Strip samples can provide full thickness information to take account of varying material properties or imperfection distribution through the thickness. Strip samples can also accommodate measurement of effects of the original surface finish or weld surface shape. Strip samples have more design flexibility than standard tests, but must be designed to limit stress concentrations and effects of local bending. (author)

  10. An acceleration test for stress corrosion cracking using humped specimen

    International Nuclear Information System (INIS)

    Kamaya, Masayuki; Fukumura, Takuya; Totsuka, Nobuo

    2003-01-01

    By using the humped specimen, which is processed by the humped die, in the slow strain rate technique (SSRT) test, fracture facet due to stress corrosion cracking (SCC) can be observed in relatively short duration. Although the cold work and concentrated stress and strain caused by the characteristic shape of the specimen accelerate the SCC, to date these acceleration effects have not been examined quantitatively. In the present study, the acceleration effects of the humped specimen were examined through experiments and finite element analyses (FEA). The experiments investigated the SCC of alloy 600 in the primary water environment of a pressurized water reactor. SSRT tests were conducted using two kinds of humped specimen: one was annealed after hump processing in order to eliminate the cold work, and the other was hump processed after the annealing treatment. The work ratio caused by the hump processing and stress/strain conditions during SSRT test were evaluated by FEA. It was found that maximum work ratio of 30% is introduced by the hump processing and that the distribution of the work ratio is not uniform. Furthermore, the work ratio is influenced by the friction between the specimen and dies as well as by the shape of dies. It was revealed that not only the cold work but also the concentrated stress and strain during SSRT test accelerate the crack initiation and growth of the SCC. (author)

  11. Friction Compensation in the Upsetting of Cylindrical Test Specimens

    DEFF Research Database (Denmark)

    Christiansen, Peter; Martins, P. A. F.; Bay, Niels Oluf

    2016-01-01

    This manuscript presents a combined numerical andexperimental methodology for determining the stress-straincurve of metallic materials from the measurements of forceand displacement obtained in the axial compression of cylindrical test specimens with friction between the specimens and the platens....... The methodology is based on minimizing the errorbetween the average surface pressure obtained from the experimental measurements of the force and displacement and thatobtained from the slab method of analysis of metal plasticity.Three different friction models based on Coulomb friction, the constant friction...... model or combined friction models are utilized .Experimental results obtained from cylindrical and Rastegaev test specimens with different lubricants combined with the experimental determination of friction by means of ring compression tests allows compensating the effect of friction...

  12. Catalogue of test specimens for non-destructive examination

    International Nuclear Information System (INIS)

    1985-05-01

    One of the key elements in assuring the integrity of reactor primary circuits is the availability of trustworthy non-destructive methods for detecting dangerous defects that may be present. Various approaches to making such examinations are being developed, including the use of ultrasonic and radiographic techniques. To demonstrate their capability and reliability, they must be tested on steel specimens reproducing the various types of faults which may arise in real primary circuit vessels and piping. Such specimens are costly to fabricate. It is therefore clearly desirable that existing specimens should be made accessible to as many organisations as possible for testing. This catalogue contains detailed Information on forty-odd deliberately flawed plates, blocks, vessels, etc. which have been produced in OECD countries, along with the name of a contact person to whom inquiries should be directed in each case

  13. A Study on Mechanical behavior of Tensile Specimen Fabricated by Laser Cutting

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Kim, G. S.; Baik, S. J.; Baek, S. Y. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The mechanical testing data are required for the assessment of dry storage of the spent nuclear fuel. Laser cutting system could be useful tools for material processing such as cutting in radioactive environment due to non-contact nature, ease in handling and the laser cutting process is most advantageous, offering the narrow kerf width and heat affected zone by using small beam spot diameter. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of the unirradiated cladding with and without oxide layer on the specimens. In the present study, the dimensional measurement and tensile test were conducted to investigate the mechanical behavior of the axial tensile test specimens depending on the material processing methods in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser cutting system was used to fabricate the tensile test specimens, and the mechanical behavior was investigated using the dimensional measurement and tensile test. It was shown that the laser beam machining could be a useful tool to fabricate the specimens and this technique will be developed for the fabrication of various types of irradiated specimens in a hotcell.

  14. A Study on Mechanical behavior of Tensile Specimen Fabricated by Laser Cutting

    International Nuclear Information System (INIS)

    Jin, Y. G.; Kim, G. S.; Baik, S. J.; Baek, S. Y.

    2016-01-01

    The mechanical testing data are required for the assessment of dry storage of the spent nuclear fuel. Laser cutting system could be useful tools for material processing such as cutting in radioactive environment due to non-contact nature, ease in handling and the laser cutting process is most advantageous, offering the narrow kerf width and heat affected zone by using small beam spot diameter. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of the unirradiated cladding with and without oxide layer on the specimens. In the present study, the dimensional measurement and tensile test were conducted to investigate the mechanical behavior of the axial tensile test specimens depending on the material processing methods in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser cutting system was used to fabricate the tensile test specimens, and the mechanical behavior was investigated using the dimensional measurement and tensile test. It was shown that the laser beam machining could be a useful tool to fabricate the specimens and this technique will be developed for the fabrication of various types of irradiated specimens in a hotcell

  15. A mechanical microcompressor for high resolution imaging of motile specimens.

    Science.gov (United States)

    Zinskie, Jessica A; Shribak, Michael; Bruist, Michael F; Aufderheide, Karl J; Janetopoulos, Chris

    2015-10-01

    In order to obtain fine details in 3 dimensions (3D) over time, it is critical for motile biological specimens to be appropriately immobilized. Of the many immobilization options available, the mechanical microcompressor offers many benefits. Our device, previously described, achieves gentle flattening of a cell, allowing us to image finely detailed structures of numerous organelles and physiological processes in living cells. We have imaged protozoa and other small metazoans using differential interference contrast (DIC) microscopy, orientation-independent (OI) DIC, and real-time birefringence imaging using a video-enhanced polychromatic polscope. We also describe an enhancement of our previous design by engineering a new device where the coverslip mount is fashioned onto the top of the base; so the entire apparatus is accessible on top of the stage. The new location allows for easier manipulation of the mount when compressing or releasing a specimen on an inverted microscope. Using this improved design, we imaged immobilized bacteria, yeast, paramecia, and nematode worms and obtained an unprecedented view of cell and specimen details. A variety of microscopic techniques were used to obtain high resolution images of static and dynamic cellular and physiological events. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Polystyrene cryostat facilitates testing tensile specimens under liquid nitrogen

    Science.gov (United States)

    Shogan, R. P.; Skalka, R. J.

    1967-01-01

    Lightweight cryostat made of expanded polystyrene reduces eccentricity in a tensile system being tested under liquid nitrogen. The cryostat is attached directly to the tensile system by a special seal, reducing misalignment effects due to cryostat weight, and facilitates viewing and loading of the specimens.

  17. Thick Concrete Specimen Construction, Testing, and Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoegh, Kyle [Univ. of Minnesota, Minneapolis, MN (United States); Khazanovich, Lev [Univ. of Minnesota, Minneapolis, MN (United States)

    2015-03-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations. A preliminary report detailed some of the challenges associated with thick reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures for using in NDE evaluation comparisons. This led to the construction of the concrete specimen presented in this report, which has sufficient reinforcement density and cross-sectional size to represent an NPP containment wall. Details on how a suitably thick concrete specimen was constructed are presented, including the construction materials, final nominal design schematic, as well as formwork and rigging required to safely meet the desired dimensions of the concrete structure. The report also details the type and methods of forming the concrete specimen as well as information on how the rebar and simulated defects were embedded. Details on how the resulting specimen was transported, safely anchored, and marked to allow access for systematic comparative NDE testing of defects in a representative NPP containment wall concrete specimen are also given. Data collection using the MIRA Ultrasonic NDE equipment and

  18. Optimization of tensile method and specimen geometry in modified ring tensile test

    International Nuclear Information System (INIS)

    Kitano, Koji; Fuketa, Toyoshi; Sasajima, Hideo; Uetsuka, Hiroshi

    2001-03-01

    Several techniques in ring tensile test are proposed in order to evaluate mechanical properties of cladding under hoop loading condition caused by pellet/cladding mechanical interaction (PCMI). In the modified techniques, variety of tensile methods and specimen geometry are being proposed in order to limit deformation within the gauge section. However, the tensile method and the specimen geometry were not determined in the modified techniques. In the present study, we have investigated the tensile method and the specimen geometry through finite element method (FEM) analysis of specimen deformation and tensile test on specimens with various gauge section geometries. In using two-piece tensile tooling, the mechanical properties under hoop loading condition can be correctly evaluated when deformation part (gauge section) is put on the top of a half-mandrel, and friction between the specimen and the half-mandrel is reduced with Teflon tape. In addition, we have shown the optimum specimen geometry for PWR 17 by 17 type cladding. (author)

  19. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-09-15

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  20. Instrumented Impact Testing: Influence of Machine Variables and Specimen Position

    International Nuclear Information System (INIS)

    Lucon, E.; McCowan, C. N.; Santoyo, R. A.

    2008-01-01

    An investigation has been conducted on the influence of impact machine variables and specimen positioning on characteristic forces and absorbed energies from instrumented Charpy tests. Brittle and ductile fracture behavior has been investigated by testing NIST reference samples of low, high and super-high energy levels. Test machine variables included tightness of foundation, anvil and striker bolts, and the position of the center of percussion with respect to the center of strike. For specimen positioning, we tested samples which had been moved away or sideways with respect to the anvils. In order to assess the influence of the various factors, we compared mean values in the reference (unaltered) and altered conditions; for machine variables, t-test analyses were also performed in order to evaluate the statistical significance of the observed differences. Our results indicate that the only circumstance which resulted in variations larger than 5 percent for both brittle and ductile specimens is when the sample is not in contact with the anvils. These findings should be taken into account in future revisions of instrumented Charpy test standards.

  1. Thermo-mechanical Fatigue Failure of Thermal Barrier Coated Superalloy Specimen

    Science.gov (United States)

    Subramanian, Rajivgandhi; Mori, Yuzuru; Yamagishi, Satoshi; Okazaki, Masakazu

    2015-09-01

    Failure behavior of thermal barrier coated (TBC) Ni-based superalloy specimens were studied from the aspect of the effect of bond coat material behavior on low cycle fatigue (LCF) and thermo-mechanical fatigue (TMF) at various temperatures and under various loading conditions. Initially, monotonic tensile tests were carried out on a MCrAlY alloy bond coat material in the temperature range of 298 K to 1273 K (25 °C to 1000 °C). Special attention was paid to understand the ductile to brittle transition temperature (DBTT). Next, LCF and TMF tests were carried out on the thermal barrier coated Ni-based alloy IN738 specimen. After these tests, the specimens were sectioned to understand their failure mechanisms on the basis of DBTT of the bond coat material. Experimental results demonstrated that the LCF and TMF lives of the TBC specimen were closely related to the DBTT of the bond coat material, and also the TMF lives were different from those of LCF tests. It has also been observed that the crack density in the bond coat in the TBC specimen was significantly dependent on the test conditions. More importantly, not only the number of cracks but also the crack penetration probability into substrate were shown to be sensitive to the DBTT.

  2. Assessment of plastic flow and fracture properties with small specimens test techniques for IFMIF-designed specimens

    International Nuclear Information System (INIS)

    Spaetig, P.; Campitelli, E.N.; Bonade, R.; Baluc, N.

    2005-01-01

    The primary mission of the International Fusion Material Irradiation Facility (IFMIF) is to generate a material database to be used for the design of various components, for the licensing and for the assessment of the safe operation of a demonstration fusion reactor. IFMIF is an accelerator-based high-energy neutron source whose irradiation volume is quite limited (0.5 l for the high fluence volume). This requires the use of small specimens to measure the irradiation-induced changes on the physical and mechanical properties of materials. In this paper, we developed finite element models to better analyze the results obtained with two different small specimen test techniques applied to the tempered martensitic steel F82H-mod. First, one model was used to reconstruct the load-deflection curves of small ball punch tests, which are usually used to extract standard tensile parameters. It was shown that a reasonable assessment of the overall plastic flow can be done with small ball punch tests. Second, we investigated the stress field sensitivity at a crack tip to the constitutive behavior, for a crack modeled in plane strain, small-scale yielding and fracture mode I conditions. Based upon a local criterion for cleavage, that appears to be the basis to account for the size and geometry effects on fracture toughness, we showed that the details of the constitutive properties play a key role in modeling the irradiation-induced fracture toughness changes. Consequently, we suggest that much more attention and efforts have to be paid in investigating the post-yield behavior of the irradiated specimens and, in order to reach this goal, we recommend the use of not only tensile specimens but also that of compression ones in the IFMIF irradiation matrices. (author)

  3. Guidebook for the fabrication of non-destructive testing (NDT) test specimens

    International Nuclear Information System (INIS)

    2001-01-01

    Non-destructive testing (NDT) test specimens constitute a very important part of training and certification of NDT personnel and are important for carrying out actual inspection and testing, and for achieving international harmonization of NDT practices. The IAEA organized an advisory group of experts to develop a Guidebook for Fabrication of NDT Test Specimens. The experts consulted the ISO/FDIS 9712-1999 requirements for training and certification of personnel and the suitability of various types of NDT test specimens that are needed to meet such requirements This guidebook presents a set of NDT test specimens, and the methodology and procedures for their fabrication

  4. Miniature specimen technology for postirradiation fatigue crack growth testing

    International Nuclear Information System (INIS)

    Mervyn, D.A.; Ermi, A.M.

    1979-01-01

    Current magnetic fusion reactor design concepts require that the fatigue behavior of candidate first wall materials be characterized. Fatigue crack growth may, in fact, be the design limiting factor in these cyclic reactor concepts given the inevitable presence of crack-like flaws in fabricated sheet structures. Miniature specimen technology has been developed to provide the large data base necessary to characterize irradiation effects on the fatigue crack growth behavior. An electrical potential method of measuring crack growth rates is employed on miniature center-cracked-tension specimens (1.27 cm x 2.54 cm x 0.061 cm). Results of a baseline study on 20% cold-worked 316 stainless steel, which was tested in an in-cell prototypic fatigue machine, are presented. The miniature fatigue machine is designed for low cost, on-line, real time testing of irradiated fusion candidate alloys. It will enable large scale characterization and development of candidate first wall alloys

  5. Test methodology and technology of fracture toughness for small size specimens

    Energy Technology Data Exchange (ETDEWEB)

    Wakai, E.; Takada, F.; Ishii, T.; Ando, M. [Japan Atomic Energy Agency, Naga-gun, Ibaraki-ken (Japan); Matsukawa, S. [JNE Techno-Research Co., Kanagawa-ken (Japan)

    2007-07-01

    Full text of publication follows: Small specimen test technology (SSTT) is required to investigate mechanical properties in the limited availability of effective irradiation volumes in test reactors and accelerator-based neutron and charged particle sources. The test methodology guideline and the manufacture processes for very small size specimens have not been established, and we would have to formulate it. The technology to control exactly the load and displacement is also required in the test technology under the environment of high dose radiation produced from the specimens. The objective of this study is to examine the test technology and methodology of fracture toughness for very small size specimens. A new bend test machine installed in hot cell has been manufactured to obtain fracture toughness and DBTT (ductile - brittle transition temperature) of reduced-activation ferritic/martensitic steels for small bend specimens of t/2-1/3PCCVN (pre-cracked 1/3 size Charpy V-notch) with 20 mm length and DFMB (deformation and fracture mini bend specimen) with 9 mm length. The new machine can be performed at temperatures from -196 deg. C to 400 deg. C under unloading compliance method. Neutron irradiation was also performed at about 250 deg. C to about 2 dpa in JMTR. After the irradiation, fracture toughness and DBTT were examined by using the machine. Checking of displacement measurement between linear gauge of cross head's displacement and DVRT of the specimen displacement was performed exactly. Conditions of pre-crack due to fatigue in the specimen preparation were also examined and it depended on the shape and size of the specimens. Fracture toughness and DBTT of F82H steel for t/2-1/3PCCVN, DFMB and 0.18DCT specimens before irradiation were examined as a function of temperature. DBTT of smaller size specimens of DFMB was lower than that of larger size specimen of t/2-1/3PCCVN and 0.18DCT. The changes of fracture toughness and DBTT due to irradiation were also

  6. Small specimen test results and application of advanced models for fracture mechanics assessment of RPV integrity; Ergebnisse von Kleinproben und Anwendung von Modellansaetzen zur bruchmechanischen Bewertung der RDB-Integritaet

    Energy Technology Data Exchange (ETDEWEB)

    Keim, Elisabeth; Huemmer, Matthias [AREVA NP GmbH (Germany); Hoffmann, Harald [VGB (Germany); Nagel, Gerhard [e-on Kernkraft (Germany); Kuester, Karin [VENE (Germany); Koenig, Guenter; Ilg, Ulf [EnBW (Germany); Widera, Martin [RWE (Germany); Rebsamen, Daniel [KKW Goesgen (Germany)

    2008-07-01

    For the RPV (reactor pressure vessel) integrity assessment the transferability of specimen test results to components is of main importance. The international project TIMES (transferability of fracture toughness of irradiated materials to components and structures) is focussed on the transferability of fracture mechanical characteristics of irradiated materials to components or structures, in order to allow the quantification of differences between sample and component characteristics based on experiments and calculations. The studies were performed for the brittle and brittle-ductile regions of the material characteristics using specimens from original RPV materials in different conditions. Based on case studies the consequence of a component assessment with postulated defects are shown when specimen-related materials properties are used. Since it is not possible to prove the transferability for an RPV in detail, component-similar effects were investigated that allow in combination with numerical modelling to quantify the safety margin. Samples and experimental procedures were developed that simulated the real component situation. The effects of crack depth and multiaxial loads, relevant for real components, were investigated with these samples. A micromechanical model was developed based on the weakest link theory and the statistical failure probability; this model is used for the prediction of fracture toughness of samples and components with defects. For a component with postulated defects the safety margin was assessed using different methodologies, based on standard fracture mechanical samples, taking into account component specific aspects. [German] Fuer die Bewertung der RDB-Integritaet ist die Uebertragbarkeit von Probenkennwerten auf Bauteile von grosser Bedeutung. Dazu wurde das Projekt ''TIMES'' - ein internationales Projekt zur Uebertragbarkeit von Bruchzaehigkeitskennwerten von bestrahlten Materialien auf Komponenten und Strukturen - durchgefuehrt, um

  7. High strain rate mechanical response of buttress-grooved tensile specimens which have undergone environmental exposure

    International Nuclear Information System (INIS)

    Weirick, L.J.

    1976-07-01

    The purpose of the corrosion compatibility program was to identify the effect of corrosion on the mechanical performance of the buttress-grooved section of the 105-mm penetrator, a section which must sustain a load during launch. It is important that the environment not deteriorate the mechanical integrity of these grooves during long-term storage. Both coated and uncoated test specimens which simulate both geometrical shape and residual stress patterns were exposed to corrosive environments of moist air, distilled water, and salt water. Some of these tests also incorporated the galvanic coupling caused by the aluminum sabot. After exposure to the corrosive environments, the specimens were pulled on a high strain rate tensile machine which simulated launch conditions. Results show that the galvanic coupling due to the aluminum sabot caused no deterioration of mechanical properties. Results do indicate that the coating applied caused a significant reduction in the fracture load. There was a dichotomy in the results as affected by the environment. Uncoated test specimens showed no change in fracture load with increasing severity of corrosion environment, whereas the coated specimens indicated a trend of decreasing load-bearing ability with increasing corrosion

  8. Examining Mechanical Strength Characteristics of Selective Inhibition Sintered HDPE Specimens Using RSM and Desirability Approach

    Science.gov (United States)

    Rajamani, D.; Esakki, Balasubramanian

    2017-09-01

    Selective inhibition sintering (SIS) is a powder based additive manufacturing (AM) technique to produce functional parts with an inexpensive system compared with other AM processes. Mechanical properties of SIS fabricated parts are of high dependence on various process parameters importantly layer thickness, heat energy, heater feedrate, and printer feedrate. In this paper, examining the influence of these process parameters on evaluating mechanical properties such as tensile and flexural strength using Response Surface Methodology (RSM) is carried out. The test specimens are fabricated using high density polyethylene (HDPE) and mathematical models are developed to correlate the control factors to the respective experimental design response. Further, optimal SIS process parameters are determined using desirability approach to enhance the mechanical properties of HDPE specimens. Optimization studies reveal that, combination of high heat energy, low layer thickness, medium heater feedrate and printer feedrate yielded superior mechanical strength characteristics.

  9. Condition For Strain-Hardening In Ecc Uniaxial Test Specimen

    DEFF Research Database (Denmark)

    Dick-Nielsen, Lars; Stang, Henrik; Poulsen, Peter Noe

    2006-01-01

    and infinite sheets under uniaxial tension. The crack is assumed to be cohesive and the cohesive law applied takes into account fiber as well as mortar properties. It is shown that the maximum crack opening observed during crack propagation in various test specimen geometries is small, 20 m and also small......This paper discusses the adequateness of the steady state flat crack criterion for crack propagation in Engineered Cementitious Composites. The investigation is performed by use of a semi-analytical model as well as a Finite Element Model. The simulations are for one crack propagating in finite...

  10. Fracture Testing with Surface Crack Specimens. [especially the residual tensile strength test

    Science.gov (United States)

    Orange, T. W.

    1974-01-01

    Recommendations are given for the design, preparation, and static fracture testing of surface crack specimens. The recommendations are preceded by background information including discussions of stress intensity factors, crack opening displacements, and fracture toughness values associated with surface crack specimens. Cyclic load and sustained load tests are discussed briefly.

  11. LOCA scenario tests of irradiated fuel rod specimens

    International Nuclear Information System (INIS)

    Scott, Harold

    2004-01-01

    Full text: The NRC's cladding performance program at Argonne National Laboratory (ANL) is testing fueled high-burnup segments subjected to LOCA integral phenomena. The data are provided to NRC and the nuclear industry for their independent assessment of the adequacy of licensing criteria for LOCA events. The tests are being conducted with high-burnup 30 cm segments from Limerick (9x9 Zry-2) and H.B. Robinson (15x15 Zry-4) reactors. Prior to testing, sibling samples are characterized with respect to fuel morphology, fuel-cladding bond, cladding oxide layer thickness, hydrogen content and high-temperature steam oxidation kinetics. Specimens that survive quench are subjected to four-point bend tests, followed by local diametral compression tests. The retention of post-quench ductility is a more limiting requirement than surviving thermal stresses during quench. Companion tests are conducted with unirradiated cladding to generate baseline data for comparison with the high-burnup fuel results. LOCA integral tests have the following sequential steps: stabilization of temperature, internal pressure and steam flow at 300 C, ramping of temperature (∼5C/s) through ballooning and burst to 1204 C, hold at 1204 C for 1-5 minutes, slow-cooling (∼3C/s) to 800 C, and water quenching at ∼800C. Two high-burnup tests were completed in 2002 with Limerick BWR rod segments: ramp to burst in argon followed by slow cooling; and the LOCA test with 5-minute hold time at 1204 C, followed by slow cooling. With the exception of burst-opening shape, results for burst temperature, burst pressure, burst length, and ballooning strain profile are more similar to, than different from, results for unirradiated Zry-2 cladding exposed to the same time-temperature history. The 3rd Limerick test with quench was performed in December 2003, and a 4th Limerick test was performed in March 2004. Tests on high-burnup Robinson PWR fuel segments are scheduled to begin in June 2004. The presentation points

  12. Failure mechanism of resistance-spot-welded specimens impacted on base material by bullets

    Directory of Open Access Journals (Sweden)

    Chunlei Fan

    2018-01-01

    Full Text Available The tests of bullet impact on the base material (BM of a simple specimen with a single resistance-spot-welded (RSW nugget of TRIP800 steel are performed to investigate the response of the RSW specimen to the ballistic debris impact on the RSW specimen. A one-stage gas gun is used to fire the bullets while a laser velocity interferometer system for any reflector (VISAR is used to measure the velocity histories of the free surfaces of the RSW specimen. The recovered RSW specimens are examined with the three-dimensional super depth digital microscope (SDDM and the scanning electro microscope (SEM. For the tests of small multiple-bullet impact, it is revealed that the wave train of the VISAR measured results and the detachment of the base material interfaces in the recovered RSW specimens are directly related to the reflection and refraction of the curved stress waves incoming to the interfaces and the free surfaces in the RSW specimens. The detachment of BM interfaces can lead to the impact failure of the RSW joints for the larger multiple-bullet impact at higher velocity, the mechanism of which is different from the case for normal incidence (spalling. For the tests of single large bullet impact, it is brought to light experimentally that the plastic strain concentration at the “notch tip” spurs either the crack near the RSW joint or the split of the nugget. The numerical simulation shows up the process of splitting the nugget: a crack initiates at the “notch tip”, propagates across the nugget interface and splits the nugget into two parts. It is indicated that the interaction between the stress waves and many interfaces/free surfaces in the RSW specimen under ballistic impact causes variable local stress triaxialities and stress Lode angles, which affects the deformation and fracture mechanism of the RSW specimen including stretching and shearing failure. It is shown that the impact failure of the RSW joints is a mixture of brittle

  13. Failure mechanism of resistance-spot-welded specimens impacted on base material by bullets

    Science.gov (United States)

    Fan, Chunlei; Ma, Bohan; Chen, Danian; Wang, Huanran; Ma, Dongfang

    2018-01-01

    The tests of bullet impact on the base material (BM) of a simple specimen with a single resistance-spot-welded (RSW) nugget of TRIP800 steel are performed to investigate the response of the RSW specimen to the ballistic debris impact on the RSW specimen. A one-stage gas gun is used to fire the bullets while a laser velocity interferometer system for any reflector (VISAR) is used to measure the velocity histories of the free surfaces of the RSW specimen. The recovered RSW specimens are examined with the three-dimensional super depth digital microscope (SDDM) and the scanning electro microscope (SEM). For the tests of small multiple-bullet impact, it is revealed that the wave train of the VISAR measured results and the detachment of the base material interfaces in the recovered RSW specimens are directly related to the reflection and refraction of the curved stress waves incoming to the interfaces and the free surfaces in the RSW specimens. The detachment of BM interfaces can lead to the impact failure of the RSW joints for the larger multiple-bullet impact at higher velocity, the mechanism of which is different from the case for normal incidence (spalling). For the tests of single large bullet impact, it is brought to light experimentally that the plastic strain concentration at the "notch tip" spurs either the crack near the RSW joint or the split of the nugget. The numerical simulation shows up the process of splitting the nugget: a crack initiates at the "notch tip", propagates across the nugget interface and splits the nugget into two parts. It is indicated that the interaction between the stress waves and many interfaces/free surfaces in the RSW specimen under ballistic impact causes variable local stress triaxialities and stress Lode angles, which affects the deformation and fracture mechanism of the RSW specimen including stretching and shearing failure. It is shown that the impact failure of the RSW joints is a mixture of brittle fracture and ductile

  14. Validatin of miniaturised tensile testing on DMLS TI6AL4V (ELI specimens

    Directory of Open Access Journals (Sweden)

    Van Zyl, Ian

    2016-11-01

    Full Text Available Direct metal laser sintering (DMLS is a relatively new technology that is developing rapidly. Since DMLS material is created by melting/solidifying tracks and layers from powder, even building geometry can influence the mechanical properties. To certify a material, the testing specimens must be designed and manufactured according to the appropriate standards. Miniaturised tensile DMLS samples could be a good alternative for express quality control, and could reduce the cost of DMLS-specific testing. In this study, as-built and stress-relieved miniaturised tensile DMLS Ti6Al4V (ELI specimens with different surface qualities were investigated. The fracture surfaces and mechanical properties of the mini-tensile specimens were analysed and compared with standard full-sized specimens also manufactured by DMLS. The obtained data showed the applicability of mini-tensile tests for the express analysis of DMLS objects if a correction factor is applied for the calculation of the load-bearing cross-section of the specimen.

  15. Metallographic analysis of irradiated RERTR-3 fuel test specimens

    International Nuclear Information System (INIS)

    Meyer, M. K.; Hofman, G. L.; Strain, R. V.; Clark, C. R.; Stuart, J. R.

    2000-01-01

    The RERTR-3 irradiation test was designed to investigate the irradiation behavior of aluminum matrix U-MO alloy dispersion fuels under high-temperature, high-fission-rate conditions. Initial postirradiation examination of RERTR-3 fuel specimens has concentrated on binary U-MO atomized fuels. The rate of matrix aluminum depletion was found to be higher than predictions based on low temperature irradiation data. Wavelength Dispersive X-ray Spectroscopy (WDS) indicates that aluminum is present in the interior of the fuel particles. WDS data is supported by a mass and volume balance calculation performed on the basis of image analysis results. The depletion of matrix aluminum seems to have no detrimental effects on fuel performance under the conditions tested to date

  16. Miniature tensile test specimens for fusion reactor irradiation studies

    International Nuclear Information System (INIS)

    Klueh, R.L.

    1985-01-01

    Three miniature sheet-type tensile specimens and a miniature rod-type specimen are being used to determine irradiated tensile properties for alloy development for fusion reactors. The tensile properties of type 316 stainless steel were determined with these different specimens, and the results were compared. Reasonably good agreement was observed. However, there were differences that led to recommendations on which specimens are preferred. 4 references, 9 figures, 6 tables

  17. Urine specimen validity test for drug abuse testing in workplace and court settings.

    Science.gov (United States)

    Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun

    2018-01-01

    In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.

  18. 10 CFR 26.165 - Testing split specimens and retesting single specimens.

    Science.gov (United States)

    2010-01-01

    ... (c), as applicable. If the specimen in Bottle A is free of any evidence of drugs or drug metabolites... suitable inquiry conducted under the provisions of § 26.63 or to any other inquiry or investigation... records must be provided to personnel conducting reviews, inquiries into allegations, or audits under the...

  19. Development of resistance welding process. 4. Preparation of pressuring enclosed creep test specimen of 7A material

    International Nuclear Information System (INIS)

    Endo, Hideo; Seki, Masayuki; Ishibashi, Fujio; Hirako, Kazuhito; Tsukada, Tatsuya

    2001-02-01

    Mechanical strength in the position welded by resistance welding system was examined in 1999. The test specimens were destroyed in the welding position in a shorter time than expected in the creep test. Therefore, test specimens were prepared to evaluate the cause of destruction. Inner-pressure enclosed creep test specimens were prepared by resistance welding method. Cladding material with low deviation of thickness and high re-crystallization rate was used. Heat treatment after resistance welding was performed to remove the influence of residual stress and the precipitation of carbides. (1) Before preparation of specimens, the welding condition was fixed. Three test specimens were prepared. Two specimens without heat treatment were transported to MMS in Oarai Engineering Center on Aug. 4, 2000. One specimen with heat treatment was transported to MMS after evaluating the residual stress to get optimum heat treatment condition. (2) Specimens were prepared with welding end plugs to both ends of ferritic ODS cladding. Enclosing sides were welded with highly strong Ferritic/Martensitic steel end plugs. The other sides were welded with ferritic ODS end plugs. (3) Some kinds of electrical wave data were obtained during performing welding. Welding position was evaluated with supersonic detector after performing welding. (4) Mechanical strength of welding position in high temperature 800degC was confirmed to be equal to or larger than that of cladding material. The highly qualified specimens in the present were successfully prepared. (author)

  20. A proposed standard round compact specimen for plane strain fracture toughness testing

    Science.gov (United States)

    Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.

    1980-01-01

    A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.

  1. 3D FDM production and mechanical behavior of polymeric sandwich specimens embedding classical and honeycomb cores

    Science.gov (United States)

    Brischetto, Salvatore; Ferro, Carlo Giovanni; Torre, Roberto; Maggiore, Paolo

    2018-04-01

    Desktop 3D FDM (Fused Deposition Modelling) printers are usually employed for the production of nonstructural objects. In recent years, the present authors tried to use this technology also to produce structural elements employed in the construction of small UAVs (Unmanned Aerial Vehicles). Mechanical stresses are not excessive for small multirotor UAVs. Therefore, the FDM technique combined with polymers, such as the ABS (Acrylonitrile Butadiene Styrene) and the PLA(Poly Lactic Acid), can be successfully employed to produce structural components. The present new work is devoted to the production and preliminary structural analysis of sandwich configurations. These new lamination schemes could lead to an important weight reduction without significant decreases of mechanical properties. Therefore, it could be possible, for the designed application (e.g., a multifunctional small UAV produced via FDM), to have stiffener and lighter structures easy to be manufactured with a low-cost 3D printer. The new sandwich specimens here proposed are PLA sandwich specimens embedding a PLA honeycomb core produced by means of the same extruder, multilayered specimens with ABS external layers and an internal homogeneous PLA core using different extruders for the two materials, sandwich specimens with external ABS skins and an internal PLA honeycomb core using different extruders for the two materials, and sandwich specimens where two different extruders have been employed for PLA material used for skins and for the internal honeycomb core. For all the proposed configurations, a detailed description of the production activity is given.Moreover, several preliminary results about three-point bending tests, different mechanical behaviors and relative delamination problems for each sandwich configuration will be discussed in depth.

  2. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    Directory of Open Access Journals (Sweden)

    Yamamoto Sohei

    2010-10-01

    Full Text Available Abstract Background Accurate evaluation of human epidermal growth factor receptor type-2 (HER2 status based on core needle biopsy (CNB specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. Methods A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH, the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. Results In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71 for 3 × 3 categories (0-1+ versus 2+ versus 3+ and 90% (κ = 0.80 for 2 × 2 categories (0-2+ versus 3+. These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77 for 3 × 3 categories and 92% (κ = 0.88 for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77 for 3 × 3 categories, and 94% (κ = 0.83 for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of

  3. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    International Nuclear Information System (INIS)

    Tsuda, Hitoshi; Kurosumi, Masafumi; Umemura, Shinobu; Yamamoto, Sohei; Kobayashi, Takayuki; Osamura, Robert Yoshiyuki

    2010-01-01

    Accurate evaluation of human epidermal growth factor receptor type-2 (HER2) status based on core needle biopsy (CNB) specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC) and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH), the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71) for 3 × 3 categories (0-1+ versus 2+ versus 3+) and 90% (κ = 0.80) for 2 × 2 categories (0-2+ versus 3+). These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77) for 3 × 3 categories and 92% (κ = 0.88) for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77) for 3 × 3 categories, and 94% (κ = 0.83) for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of 2+ differed among specimens processed at

  4. Methods and devices for small specimen testing at the Japan Atomic Energy Research Institute

    International Nuclear Information System (INIS)

    Jitsukawa, Shiro; Kizaki, Minoru; Umino, Akira; Shiba, Kiyoyuki; Hishinuma, Akimichi

    1993-01-01

    Devices for a punch test on annular notched specimens, small punch (SP) tests, and miniaturized tension tests in hot cells were developed. A micro-manipulator to handle small specimens and an electro-discharge machine (EDM) to extract miniaturized tension specimens and annular notched specimens from transmission electron microscopy (TEM) disks were also fabricated. These devices were designed and made for remote operation in hot cells. Preliminary tests to evaluate the applicability of test methods were carried out. Correlation between SP test results and tensile properties was not strong. Miniaturized tensile results were reasonably similar to the results with larger specimens. The ductile-brittle transition temperature (DBTT) by the punch test on annular notched specimens was higher than that obtained from the SP test. However, materials dependence of the DBTT was different from that measured by standard Charpy V-notch (CVN) tests. This may be due to a specimen size effect

  5. Stress Wave Attenuation in Aluminum Alloy and Mild Steel Specimens Under SHPB Tensile Testing

    Science.gov (United States)

    Pothnis, J. R.; Ravikumar, G.; Arya, H.; Yerramalli, Chandra S.; Naik, N. K.

    2018-02-01

    Investigations on the effect of intensity of incident pressure wave applied through the striker bar on the specimen force histories and stress wave attenuation during split Hopkinson pressure bar (SHPB) tensile testing are presented. Details of the tensile SHPB along with Lagrangian x- t diagram of the setup are included. Studies were carried out on aluminum alloy 7075 T651 and IS 2062 mild steel. While testing specimens using the tensile SHPB setup, it was observed that the force calculated from the transmitter bar strain gauge was smaller than the force obtained from the incident bar strain gauge. This mismatch between the forces in the incident bar and the transmitter bar is explained on the basis of stress wave attenuation in the specimens. A methodology to obtain force histories using the strain gauges on the specimen during SHPB tensile testing is also presented. Further, scanning electron microscope images and photomicrographs are given. Correlation between the microstructure and mechanical properties is explained. Further, uncertainty analysis was conducted to ascertain the accuracy of the results.

  6. The effect of thermal treatment on the mechanical properties of PLLA tubular specimens

    Directory of Open Access Journals (Sweden)

    Arbeiter Daniela

    2016-09-01

    Full Text Available Conventional permanent stent systems for vascular applications are associated with long-term risks, such as restenosis and thrombosis. To overcome these limitations, novel approaches using various biodegradable materials for stent construction have been investigated. In this context, thermal treatment of polymer materials is investigated to adjust the mechanical properties of biodegradable stents. In this work polymeric tubular specimens of biodegradable poly(L-lactide (PLLA were extruded and subjected to a molding process using different temperatures above glass transition temperature TG. Physicochemical properties of the molded samples were analyzed using DSC measurements and uniaxial tensile tests. The molding process resulted in a weakening of the PLLA tubular specimens with a simultaneous increase in the degree of crystallinity (χ.

  7. Small-scale Specimen Testing of Monolithic U-Mo Fuel Foils

    Energy Technology Data Exchange (ETDEWEB)

    Ramprashad Prabhakaran; Douglas E. Burkes; James I. Cole; Indrajit Charit; Daniel M. Wachs

    2008-10-01

    The objective of this investigation is to develop a shear punch testing (SPT) procedure and standardize it to evaluate the mechanical properties of irradiated fuels in a hot-cell so that the tensile behavior can be predicted using small volumes of material and at greatly reduced irradiation costs. This is highly important in the development of low-enriched uranium fuels for nuclear research and test reactors. The load-displacement data obtained using SPT can be interpreted in terms of and correlated with uniaxial mechanical properties. In order to establish a correlation between SPT and tensile data, sub-size tensile and microhardness testing were performed on U-Mo alloys. In addition, efforts are ongoing to understand the effect of test parameters (such as specimen thickness, surface finish, punch-die clearance, crosshead velocity and carbon content) on the measured mechanical properties, in order to rationalize the technique, prior to employing it on a material of unknown strength.

  8. Small-scale Specimen Testing of Monolithic U-Mo Fuel Foils

    International Nuclear Information System (INIS)

    Ramprashad Prabhakaran; Douglas E. Burkes; James I. Cole; Indrajit Charit; Daniel M. Wachs

    2008-01-01

    The objective of this investigation is to develop a shear punch testing (SPT) procedure and standardize it to evaluate the mechanical properties of irradiated fuels in a hot-cell so that the tensile behavior can be predicted using small volumes of material and at greatly reduced irradiation costs. This is highly important in the development of low-enriched uranium fuels for nuclear research and test reactors. The load-displacement data obtained using SPT can be interpreted in terms of and correlated with uniaxial mechanical properties. In order to establish a correlation between SPT and tensile data, sub-size tensile and microhardness testing were performed on U-Mo alloys. In addition, efforts are ongoing to understand the effect of test parameters (such as specimen thickness, surface finish, punch-die clearance, crosshead velocity and carbon content) on the measured mechanical properties, in order to rationalize the technique, prior to employing it on a material of unknown strength

  9. Design of creep machine and creep specimen chamber for carrying out creep tests in flowing liquid sodium

    Energy Technology Data Exchange (ETDEWEB)

    Ravi, S., E-mail: sravi@igcar.gov.in; Laha, K.; Sakthy, S.; Mathew, M.D.; Jayakumar, T.

    2014-02-15

    Highlights: • Design of a lever type creep machine for carrying out creep test in flowing sodium. • Leveling of lever during creep was achieved by automated movement of fulcrum. • Design of creep chamber for providing constant sodium flow rate across creep specimen. • Minimum use of bellow in chamber for sodium containment and mechanical isolation. • Mini-lever mechanism to counter balance load reduction on specimen due to bellow stiffness. - Abstract: A creep testing system has been designed, fabricated, installed and validated for carrying out creep tests in flowing liquid sodium. The testing system consists of two sections namely creep testing machine and an environmental chamber. The testing system has the ability of (i) applying tensile load to the test specimen through a lever, (ii) monitoring continuously the creep elongation and (iii) allowing sodium to flow around the creep specimen at constant velocity. The annular space between the creep specimen and the environmental chamber has been suitably designed to maintain constant sodium flow velocity. Primary and secondary bellows are employed in the environmental chamber to (i) mechanically isolate the creep specimen, (ii) prevent the flowing sodium in contact with air and (iii) maintain an argon gas cover to the leaking sodium if any from primary bellow, with a provision to an alarm get activated by a spark plug. The lever-horizontality during creep test has been maintained by automatically lifting up the fulcrum instead of lowering down the pull rod as conventionally used. A mini lever mechanism has been incorporated in the load train to counter balance the load reduction on specimen from the changing stiffness of the bellows. The validation of the testing system has been established by carrying out creep tests on 316L(N) stainless steel at 873 K over a wide stress range and comparing the results with those obtained in air by employing the developed and conventional creep testing machines.

  10. Comparison of gross anatomy test scores using traditional specimens vs. QuickTime Virtual Reality animated specimens

    Science.gov (United States)

    Maza, Paul Sadiri

    movie modules. The comparison of the two sample group means of the examinations show that there was no difference in results between using QTVR movie modules to test gross anatomy knowledge versus using physical specimens. The results of this study are discussed to explain the benefits of using such computer based anatomy resources in gross anatomy assessments.

  11. Service-cycle component-feature specimen TMF testing of steam turbine rotor steels

    Energy Technology Data Exchange (ETDEWEB)

    Radosavljevic, M.; Holdsworth, S.R. [Eidgenoessische Materialpruefungs- und Forschungsanstalt, Duebendorf (Switzerland); Mazza, E. [Eidgenoessische Materialpruefungs- und Forschungsanstalt, Duebendorf (Switzerland); Eidgenoessische Technische Hochschule (ETH), Zurich (Switzerland); Grossmann, P.; Ripamonti, L. [ALSTOM Power (Switzerland) Ltd., Baden (Switzerland)

    2010-07-01

    This paper reviews the methodology adopted in a Swiss Research Collaboration to devise a component-feature representative specimen geometry and the TMF cycle parameters necessary to closely simulate arduous steam turbine operating duty. Implementation of these service-like experimental conditions provides a practical indication of the effectiveness of deformation and crack initiation endurance predictions. Comprehensive post test inspection provides evidence to demonstrate the physical realism of the laboratory simulations in terms of the creep-fatigue damage generated during the benchmark tests. Mechanical response results and physical damage observations are presented and their practical implications discussed for the example of a 2%CrMoNiWV rotor service cycle. (orig.)

  12. The feasibility of prefatigued sub size specimens to fracture mechanical studies in inert and in reactor environments

    International Nuclear Information System (INIS)

    Toivonen, A.; Moilanen, P.; Taehtinen, S.; Aaltonen, P.; Wallin, K.

    1998-01-01

    The feasibility of sub size specimens to fracture mechanical tests in inert and in reactor environment is studied in this paper. The need for using sub size specimens has arised from the need to study highly irradiated materials as well as to study localised stress corrosion cracking, i.e. stress corrosion cracking in very narrow heat affected zones for example in welded thin walled pipes. This paper focuses on the effects of high J-integral values on ductile tearing and on environmentally assisted crack growth rate. The main focus is on the stress corrosion tests. The subject is approached first by theoretical discussion. The experimental study consists of J-R tests in air and of slow J-R tests in simulated boiling water reactor (BWR) environment. In most cases the tests were continued until the J-integral level was significantly above the maximum allowable J values for ductile fracture toughness characterisation prescribed in test standards. The results indicate that the measurement capacity of the specimens depends on the specimen dimensions in J-R tests in air, as could be expected. The measurement capacity limitations are not necessarily important in stress corrosion testing as the environmentally assisted crack growth rate can be measured even without exceeding the J-integral limits given in J-R standards. The theoretical and experimental studies indicate that stress corrosion studies are not limited to linear elastic fracture mechanics approach, but elastic plastic fracture mechanics is applicable as well. (author)

  13. Investigation of the mechanical and physical properties of greywacke specimens

    Czech Academy of Sciences Publication Activity Database

    Holub, Karel; Konečný, Pavel; Knejzlík, Jaromír

    2009-01-01

    Roč. 46, č. 1 (2009), s. 188-193 ISSN 1365-1609 Institutional research plan: CEZ:AV0Z30860518 Keywords : greywacke * mechanical and physical properties Subject RIV: DC - Siesmology, Volcanology, Earth Structure Impact factor: 1.142, year: 2009 www.elsevier.com/locate ijrmms

  14. A Novel Piezo-Actuator-Sensor Micromachine for Mechanical Characterization of Micro-Specimens

    Directory of Open Access Journals (Sweden)

    Leila Ladani

    2010-12-01

    Full Text Available Difficulties associated with testing and characterization of materials at microscale demands for new technologies and devices that are capable of measuring forces and strains at microscale. To address this issue, a novel electroactive-based micro-electro-mechanical machine is designed. The micromachine is comprised of two electroactive (piezoelectric micro-elements mounted on a rigid frame. Electrical activation of one of the elements causes it to expand and induce a stress in the intervening micro-specimen. The response of the microspecimen to the stress is measured by the deformation and thereby voltage/resistance induced in the second electro-active element. The concept is theoretically proven using analytical modeling in conjunction with non-linear, three dimensional finite element analyses for the micromachine. Correlation of the output voltage to the specimen stiffness is shown. It is also demonstrated through finite element and analytical analysis that this technique is capable of detecting non-linear behavior of materials. A characteristic curve for an isotropic specimen exhibiting linear elastic behavior is developed. Application of the proposed device in measuring coefficient of thermal expansion is explored and analytical analysis is conducted.

  15. Standard test method for laboratory evaluation of magnesium sacrificial anode test specimens for underground applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This test method covers a laboratory procedure that measures the two fundamental performance properties of magnesium sacrificial anode test specimens operating in a saturated calcium sulfate, saturated magnesium hydroxide environment. The two fundamental properties are electrode (oxidation potential) and ampere hours (Ah) obtained per unit mass of specimen consumed. Magnesium anodes installed underground are usually surrounded by a backfill material that typically consists of 75 % gypsum (CaSO4·2H2O), 20 % bentonite clay, and 5 % sodium sulfate (Na2SO4). The calcium sulfate, magnesium hydroxide test electrolyte simulates the long term environment around an anode installed in the gypsum-bentonite-sodium sulfate backfill. 1.2 This test method is intended to be used for quality assurance by anode manufacturers or anode users. However, long term field performance properties may not be identical to property measurements obtained using this laboratory test. Note 1—Refer to Terminology G 15 for terms used ...

  16. Prediction of retained residual stresses in laboratory fracture mechanics specimens extracted from welded components

    International Nuclear Information System (INIS)

    Hurlston, R.G.; Sherry, A.H.; James, P.; Sharples, J.K.

    2015-01-01

    The measurement of weld material fracture toughness properties is important for the structural integrity assessment of engineering components. However, welds can contain high levels of residual stress and these can be retained in fracture mechanics specimens, particularly when machined from non-stress relieved welds. Retained residual stresses can make the measurement of valid fracture toughness properties difficult. This paper describes the results of analytical work undertaken to investigate factors that can influence the magnitude and distribution of residual stresses retained in fracture mechanics specimen blanks extracted from as-welded ferritic and austenitic stainless steel plates. The results indicate that significant levels of residual stress can be retained in specimen blanks prior to notching, and that the magnitude and distribution of stress is dependent upon material properties, specimen geometry and size, and extraction location through the thickness of the weld. Finite element modelling is shown to provide a useful approach for estimating the level and distributions of retained residual stresses. A new stress partitioning approach has been developed to estimate retained stress levels and results compare favourably with FE analysis and available experimental data. The approach can help guide the selection of specimen geometry and machining strategies to minimise the level of residual stresses retained in fracture mechanics specimen blanks extracted from non stress-relieved welds and thus improve the measurement of weld fracture toughness properties. - Highlights: • A simplified method for generating realistic weld residual stresses has been developed. • It has been shown that significant levels of residual stress can be retained within laboratory fracture mechanics specimens. • The level and distribution is dependant upon material, specimen type, specimen size and extraction location. • A method has been developed to allow estimates of the

  17. Mechanical Testing of MLCCs

    Science.gov (United States)

    Teverovsky, Alexander A.

    2016-01-01

    Cracking of multilayer ceramic capacitors, MLCCs, remains a serious problem for space systems. This problem increases substantially for large size capacitors and in cases when manual soldering is involved or the system experiences mechanical shock or vibration. In any case, a fracture occurs when the sum of external and internal mechanical stresses exceeds the strength of the part. To reduce the probability of cracking, the level of stress should be reduced, e.g. by optimizing the assembly workmanship and rules for board design, and the strength of the parts increased by selecting the most mechanically robust capacitors. The latter might possibly be achieved by selecting MLCCs based on the in-situ measurements of mechanical characteristics using four types of tests: flexural strength, hardness, fracture toughness, and flex bend testing. Note that military specifications MIL-PRF-123 and MIL-PRF-55681 do not have requirements for mechanical testing of the parts. However, specifications for automotive industry components employ two types of mechanical tests: beam load (break strength) test per AEC-Q200-003 and board flex test per AEC-Q200-005. A recent military specification for thin dielectric capacitors, MIL-PRF-32535, has one mechanical test, board flex testing, that is similar to AEC-Q200-005. The purpose of this report was assessment of the efficiency of different mechanical tests for selection robust capacitors and comparison of mechanical characteristics of Base Metal Electrode (BME) and Precious Metal Electrode (PME) capacitors. The report has three parts related to the first three mechanical tests mentioned above.

  18. On impact testing of subsize Charpy V-notch type specimens

    International Nuclear Information System (INIS)

    Mikhail, A.S.; Nanstad, R.K.

    1994-01-01

    The potential for using subsize specimens to determine the actual properties of reactor pressure vessel steels is receiving increasing attention for improved vessel condition monitoring that could be beneficial for light-water reactor plant-life extension. This potential is made conditional upon, on the one hand, by the possibility of cutting samples of small volume from the internal surface of the pressure vessel for determination of actual properties of the operating pressure vessel. The plant-life extension will require supplemental surveillance data that cannot be provided by the existing surveillance programs. Testing of subsize specimens manufactured from broken halves of previously tested surveillance Charpy V-notch (CVN) specimens offers an attractive means of extending existing surveillance programs. Using subsize CVN type specimens requires the establishment of a specimen geometry that is adequate to obtain a ductile-to-brittle transition curve similar to that obtained from full-size specimens. This requires the development of a correlation of transition temperature and upper-shelf toughness between subsize and full-size specimens. The present study was conducted under the Heavy-Section Steel Irradiation Program. Different published approaches to the use of subsize specimens were analyzed and five different geometries of subsize specimens were selected for testing and evaluation. The specimens were made from several types of pressure vessel steels with a wide range of yield strengths, transition temperatures, and upper-shelf energies (USEs). Effects of specimen dimensions, including depth, angle, and radius of notch have been studied. The correlation of transition temperature determined from different types of subsize specimens and the full-size specimen is presented. A new procedure for transforming data from subsize specimens was developed and is presented

  19. Mismatch effect on CT specimen mechanical effect and consequences on the weld toughness characterization

    International Nuclear Information System (INIS)

    Marie, S.; Nedelec, M.

    2012-01-01

    The welded joints are particularly sensitive areas in the structures in terms of harmfulness of defects. Given the complexity of the problem (geometry poorly controlled, multi-material aspect, the potential influence of residual stresses), the tests are conducted based on pessimistic assumptions that can wrap all the uncertainties of the problem. In the case of a defect assessment, the considered toughness is deduced from conventional characterization tests with a crack in the welding, considering the current standards, ISO 12135 or ASTM E-1820 which are valid only for an homogeneous specimen. In 2010, a new standard ISO 16563 was published to address the specificity of welded joints. If it covers some of the difficulties, it remains incomplete. In nuclear piping, welds have a mismatch M, i.e. the ratio between the yield strength of the weld metal and the base metal, usually greater than 1: this avoids any problem of strain localization at the junction and ensure that the stresses in the base metal are also easily supported by the welded joint. In this configuration, it turns out that for a given mechanical loading, a crack in the weld located generally has a solicitation, quantified by the parameter J, less (depending on the size of the junction) to those that would see the same crack located in the base metal. Unfortunately, this phenomenon exists also potentially for a characterization test, which would overestimate the true toughness of the welded joint. Plasticity that develops from the crack tip can quickly reach this interface and be affected. To evaluate this phenomenon, we considered two types of representative welded joint (PWR secondary loop ferritic weld and a 316 stainless steel weld) and performed a F.E. analysis of the multi-material CT specimen mechanical answer and on the η coefficient conventionally used to derive the plastic component of J from the area under the curve force-opening displacement. (authors)

  20. Development of European creep crack growth testing code of practice for industrial specimens

    International Nuclear Information System (INIS)

    Dogan, B.; Nikbin, K.; Petrovski, B.

    2004-01-01

    The integrity and residual life assessment of high temperature components require defects, detected or assumed to exist, through minimum allowable limits of detectable flaws using nondestructive testing methods. It relies on information obtained from the material's mechanical, uniaxial creep, creep crack initiation and growth properties. The information derived from experiments needs to be validated and harmonised following a Code of Practice that data variability between different institutions can be reduced to a minimum. The present paper reports on a Code of Practice (CoP) being prepared within the framework of the partially European Commission funded project CRETE. The novel aspect of the presented CoP is the inclusion of component relevant industrial specimen geometries. It covers testing and analysis of Creep Crack growth (CCG) in metallic materials at elevated temperature using six different cracked geometries that have been validated in. It aims to give advice on testing, measurements and analysis of creep crack growth data for a range of creep brittle to creep ductile materials using component service relevant specimen geometries and sizes. The CoP may be used for material selection criteria and inspection requirements for damage tolerant applications. In quantitative terms, these types of tests can be used to assess the individual and combined effects of metallurgical, fabrication, operating temperature, and loading conditions on creep crack growth life. Further issues will be addressed including material properties, damage and crack growth related constraint effect, stress relaxation and stress-strain fields, residual stresses, partitioning displacement, analysis of elastic creep, elastic compliance measurements

  1. Tensile tests and metallography of brazed AISI 316L specimens after irradiation

    International Nuclear Information System (INIS)

    Groot, P.; Franconi, E.

    1994-01-01

    Stainless steel type 316L tensile specimens were vacuum brazed with three kinds of alloys: BNi-5, BNi-6, and BNi-7. The specimens were irradiated up to 0.7 dpa at 353 K in the High Flux Reactor at JRC Petten, the Netherlands. Tensile tests were performed at a constant displacement rate of 10 -3 s -1 at room temperature in the ECN hot cell facility. BNi-5 brazed specimens showed ductile behaviour. Necking and fractures were localized in the plate material. BNi-6 and BNi-7 brazed specimens failed brittle in the brazed zone. This was preceded by uniform deformation of the plate material. Tensile test results of irradiated specimens showed higher stresses due to radiation hardening and a reduction of the elongation of the plate material compared to the reference. SEM examination of the irradiated BNi-6 and BNi-7 fracture surfaces showed nonmetallic phases. These phases were not found in the reference specimens. ((orig.))

  2. Macrocrack propagation in concrete specimens under sustained loading: Study of the physical mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, Pierre, E-mail: pierre.rossi@lcpc.fr; Boulay, Claude; Tailhan, Jean-Louis; Martin, Eric; Desnoyers, Dominic

    2014-09-15

    This study presents a series of 4-point bending tests performed to describe the delayed behavior of unreinforced pre-cracked beams under low, moderate and high sustained loading levels. The deflection creep rate, the failure time and the load level were assessed. A linear relation, in a semi-log scale, was found for the deflection creep rate at high load levels. In addition, a linear relation, in a log–log scale, between the secondary deflection creep rate and failure time was observed. Besides, it was shown that the secondary creep deflection rate increases with the sustained loading level and the macrocrack propagation rate when macrocrack propagation occurs during the sustained loading. Physical mechanisms are proposed to explain these results and may be summarized as follows: the delayed behavior of an unreinforced cracked concrete specimen under sustained loading is mainly due to the cracking evolution, thus the creation of microcracks and/or the propagation of a macrocrack.

  3. FFTF irradiation of fracture mechanics specimens for out-of-core structures

    International Nuclear Information System (INIS)

    King, D.C.

    1978-09-01

    The National Program Plan has established data requirements for out-of-core structures for FBRs. Significant FFTF irradiation space with moderate gamma heating levels is required to irradiate relatively large fracture mechanics specimens to total neutron fluences ranging between 5 x 10 21 and 5 x 10 22 n/cm 2 and temperatures which range between 400 0 C (750 0 F) and 650 0 C (1200 0 F). Priority 1 data on stainless steel welds requires a test volume of 7443 cm 3 (454 in 3 ). Priority 2 data on 304 and 316 SS and Inconel 718 materials and Inconel 718 welds requires 2760 cm 3 (168 in 3 ). Priority 3 data on stainless steels, other nickel-base alloys, and ferritics requires 33,118 cm 3 (2021 in 3 ). Priority 4 data at elevated temperatures on stainless steels, other nickel-base alloys and ferritics requires 69,182 cm 3

  4. Macrocrack propagation in concrete specimens under sustained loading: Study of the physical mechanisms

    International Nuclear Information System (INIS)

    Rossi, Pierre; Boulay, Claude; Tailhan, Jean-Louis; Martin, Eric; Desnoyers, Dominic

    2014-01-01

    This study presents a series of 4-point bending tests performed to describe the delayed behavior of unreinforced pre-cracked beams under low, moderate and high sustained loading levels. The deflection creep rate, the failure time and the load level were assessed. A linear relation, in a semi-log scale, was found for the deflection creep rate at high load levels. In addition, a linear relation, in a log–log scale, between the secondary deflection creep rate and failure time was observed. Besides, it was shown that the secondary creep deflection rate increases with the sustained loading level and the macrocrack propagation rate when macrocrack propagation occurs during the sustained loading. Physical mechanisms are proposed to explain these results and may be summarized as follows: the delayed behavior of an unreinforced cracked concrete specimen under sustained loading is mainly due to the cracking evolution, thus the creation of microcracks and/or the propagation of a macrocrack

  5. Application of small specimens to fracture mechanics characterization of irradiated pressure vessel steels

    International Nuclear Information System (INIS)

    Sokolov, M.A.; Wallin, K.; McCabe, D.E.

    1996-01-01

    In this study, precracked Charpy V-notch (PCVN) specimens were used to characterize the fracture toughness of unirradiated and irradiated reactor pressure vessel steels in the transition region by means of three-point static bending. Fracture toughness at cleavage instability was calculated in terms of elastic-plastic K Jc values. A statistical size correction based upon weakest-link theory was performed. The concept of a master curve was applied to analyze fracture toughness properties. Initially, size-corrected PCVN data from A 533 grade B steel, designated HSST Plate O2, were used to position the master curve and a 5% tolerance bound for K Jc data. By converting PCVN data to IT compact specimen equivalent K Jc data, the same master curve and 5% tolerance bound curve were plotted against the Electric Power Research Institute valid linear-elastic K Jc database and the ASME lower bound K Ic curve. Comparison shows that the master curve positioned by testing several PCVN specimens describes very well the massive fracture toughness database of large specimens. These results give strong support to the validity of K Jc with respect to K Ic in general and to the applicability of PCVN specimens to measure fracture toughness of reactor vessel steels in particular. Finally, irradiated PCVN specimens of other materials were tested, and the results are compared to compact specimen data. The current results show that PCVNs demonstrate very good capacity for fracture toughness characterization of reactor pressure vessel steels. It provides an opportunity for direct measurement of fracture toughness of irradiated materials by means of precracking and testing Charpy specimens from surveillance capsules. However, size limits based on constraint theory restrict the operational test temperature range for K Jc data from PCVN specimens. 13 refs., 8 figs., 1 tab

  6. Development of small specimen test techniques. Development of a remote controlled small punch testing apparatus

    International Nuclear Information System (INIS)

    Ohmi, Masao; Saito, Junichi; Ooka, Norikazu; Jitsukawa, Shiro; Hishinuma, Akimichi; Umino, Akira.

    1997-01-01

    An accelerator-driven deuterium-lithium (d-Li) stripping reaction-type neutron source, such as the International Fusion Materials Irradiation Facility (IFMIF) planned by the International Energy Agency is recognized as one of the most promising facility to obtain test environments of high-energy neutrons for fusion reactor materials development. The limitation on the available irradiation volume of the irradiation facility requires the development of the small specimen test techniques (SSTT). Application of SSTT to evaluate the degradation of various components in the light water reactor for the life extension is expected to be also quite beneficial. A remote-controlled testing machine for the Small Punch (SP) and miniaturized tensile tests was developed at the hot laboratory of the Japan Materials Testing Reactor (JMTR). The machine is designed for testing at temperatures ranging between 93 and 1,123 K to evaluate the temperature dependence of the strength of materials including the embrittlement at low temperatures and the softening at elevated temperatures. The tests are performed in a vacuum or in an inert gas environment. The machine has been installed in a hot cell and is being used for the round robin test program of the SP test method. The round robin test program is planned to identify the capability of the test method and to establish a standard test procedure. The configuration and the specifications of the test machine are introduced and the results of the SP tests are also shown. (author)

  7. Molecular testing of human papillomavirus in cervical specimens

    International Nuclear Information System (INIS)

    Gazzaz, Faten Salah B.

    2007-01-01

    Objective was to improve the diagnosis of cervical neoplasia by early detection of human papillomavirus (HPV) in uterine cervix, by adding molecular testing of HPV using hybrid capture 2 (HC2) and polymerase chain reaction (PCR) tests to Papanicoalou (Pap) test. One hundred women were enrolled in this study. The mean age (mean+-SD) was 41.97+- 8.76 years and range was 27-65 years. All women had undergone cervical cytological screening with cervical cytology, HPV DNA testing by HC2 and PCR, during the period from January to December 2006, at King Abdul-Aziz University Hospital (KAAUH) and King Fahd research Center, Jeddah, Saudi Arabia. The results were obtained by HC2 for detection of HPV were 5(5%) high-risk HPV, one low-risk HPV (1%) and 94(94%) negative cases. The PCR detected only 4(4%) cases. Using the HC2 test as a reference, sensitivity, specificity, positive predictive, negative predictive values and accuracy of base line Pap were 50, 85, 17.7, 96.4 and 83%; of final Pap smear were 100, 96.8, 66.7, 100, and 97% and for PCR were 66.7, 100, 100, 97.9 and 98%. The Pap test was repeated within a year for patients with abnormal Pap test with positive HPV DNA. Combined screening by cytology and HPV testing using both HC2 and PCR sensitively detects women with existing disease. The absence of HPV DNA provides reassurance that patients are unlikely to develop cancer for several years. We suggest using Pap with HC2 and PCR in screening programs to ensure that women with the double negative result at baseline might safely be screened at longer intervals. (author)

  8. Small specimen test technology of fracture toughness in structural material F82H steel for fusion nuclear reactors

    International Nuclear Information System (INIS)

    Wakai, Eiichi; Ohtsuka, Hideo; Jitsukawa, Shiro; Matsukawa, Shingo; Ando, Masami

    2006-03-01

    Small specimen test technology (SSTT) has been developed to investigate mechanical properties of nuclear materials. SSTT has been driven by limited availability of effective irradiation volumes in test reactors and accelerator-based neutron and charged particle sources, and it is very useful for the reduction of waste materials produced in nuclear engineering. In this study new bend test machines have been developed to obtain fracture behaviors of F82H steel for very small bend specimens of pre-cracked t/2-1/3CVN (Charpy V-notch) with 20 mm-length and DFMB (deformation and fracture mini bend specimen) with 9 mm-length and disk compact tension of 0.18DCT type, and fracture behaviors were examined to evaluate DBTT (ductile-brittle transition temperature) at temperature from -180 to 25degC. The effect of specimen size on DBTT of F82H steel was also examined by using Charpy type specimens such as 1/2t-CVN, 1/3CVN and t/2-1/3CVN. In this paper, it also provides the information of the specimens irradiated at 250degC and 350degC to about 2 dpa in the capsule of 04M-67A and 04M-68A of JMTR experiments. (author)

  9. Shear Punch Testing of BOR-60 Irradiated TEM Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Saleh, Tarik A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Quintana, Matthew Estevan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Romero, Tobias J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-13

    As a part of the project “High Fidelity Ion Beam Simulation of High Dose Neutron Irradiation” an Integrated Research Program (IRP) project from the U.S. Department of Energy, Nuclear Energy University Programs (NEUP), TEM geometry samples of ferritic cladding alloys, Ni based super alloys and model alloys were irradiated in the BOR-60 reactor to ~16 dpa at ~370°C and ~400°C. Samples were sent to Los Alamos National Laboratory and subjected to shear punch testing. This report presents the results from this testing.

  10. Acquisition and preparation of specimens of rock for large-scale testing

    International Nuclear Information System (INIS)

    Watkins, D.J.

    1981-01-01

    The techniques used for acquisition and preparation of large specimens of rock for laboratory testing depend upon the location of the specimen, the type of rock and the equipment available at the sampling site. Examples are presented to illustrate sampling and preparation techniques used for two large cylindrical samples of granitic material, one pervasively fractured and one containing a single fracture

  11. Laser weld reconstitution of conventional Charpy and Miniaturized Notch Test (MNT) specimens

    International Nuclear Information System (INIS)

    Manahan, M.P.; Williams, J.; Martukanitz, R.P.

    1993-01-01

    As nuclear power plants approach end-of-license (EOL) and consideration is given to license renewal, there is an ever increasing need to expand the amount of data obtainable from the original surveillance specimens. A laser welding technique to reconstitute broken Charpy specimens is being developed to produce both conventional and miniaturized Charpy specimens. This paper reports on early laser welding development efforts and summarizes previous proof-of-principle experiments on a 1/16 scale miniaturized Charpy test. In order to benchmark the laser welding procedure, the laser-reconstituted specimen data have been compared with the original specimen data. In addition, the microstructure after welding has been examined to ensure that the material in the vicinity of the notch is essentially unchanged after the welding process. Data which characterize the thermal transient during welding are obtained by attaching thermocouples to the specimens. Other important considerations include perturbation of the stress field near the notch, dynamic stress waves, and contact of the weld region with the tup. Precise control of welding parameters has been demonstrated, heat-affected zones as small as 0.25 mm can be achieved, and sufficient penetration depth can be obtained to enable welding thick sections (1T or greater) to yield conventional Charpy specimens or fracture toughness specimens and thin sections (∼5 mm) to yield Miniaturized Notch Test (MNT) specimens

  12. Comparison of Three Different Methods for Pile Integrity Testing on a Cylindrical Homogeneous Polyamide Specimen

    Science.gov (United States)

    Lugovtsova, Y. D.; Soldatov, A. I.

    2016-01-01

    Three different methods for pile integrity testing are proposed to compare on a cylindrical homogeneous polyamide specimen. The methods are low strain pile integrity testing, multichannel pile integrity testing and testing with a shaker system. Since the low strain pile integrity testing is well-established and standardized method, the results from it are used as a reference for other two methods.

  13. Redesigning axial-axial (biaxial) cruciform specimens for very high cycle fatigue ultrasonic testing machines.

    Science.gov (United States)

    Montalvão, Diogo; Wren, Andrew

    2017-11-01

    The necessity to increase performances in terms of lifetime and security in mechanical components or structures is the motivation for intense research in fatigue. Applications range from aeronautics to medical devices. With the development of new materials, there is no longer a fatigue limit in the classical sense, where it was accepted that the fatigue limit is the stress level such that there is no fracture up to 1E7 cycles. The recent development of ultrasonic testing machines where frequencies can go as high as 20 kHz or over enabled tests to be extended to ranges larger than 1E9 in just a few days. This area of studies is now known as Very High Cycle Fatigue (VHCF). On the other hand, most of the existing test equipment in the market for both classical and VHCF are uniaxial test machines. However, critical components used in Engineering applications are usually subjected to complex multi-axial loading conditions. In this paper, it is presented the methodology to redesigning existing cruciform test specimens that can be used to create an in-plane biaxial state of stress when used in 'uniaxial' VHCF ultrasonic testing machines (in this case, the term 'uniaxial' is used not because of the state of stress created at the centre of the specimen, but because of the direction at which the load is applied). The methodology is explained in such a way that it can be expanded to other existing designs, namely cruciform designs, that are not yet used in VHCF. Also, although the approach is presented in simple and logical terms, it may not be that obvious for those who have a more focused approach on fatigue rather than on modal analysis. It is expected that by contributing to bridging the gap between the sciences of modal analysis and fatigue, this research will help and encourage others exploiting new capabilities in VHCF.

  14. Stress-deformed state of cylindrical specimens during indirect tensile strength testing

    Directory of Open Access Journals (Sweden)

    Levan Japaridze

    2015-10-01

    Full Text Available In this study, the interaction between cylindrical specimen made of homogeneous, isotropic, and linearly elastic material and loading jaws of any curvature is considered in the Brazilian test. It is assumed that the specimen is diametrically compressed by elliptic normal contact stresses. The frictional contact stresses between the specimen and platens are neglected. The analytical solution starts from the contact problem of the loading jaws of any curvature and cylindrical specimen. The contact width, corresponding loading angle (2θ0, and elliptical stresses obtained through solution of the contact problems are used as boundary conditions for a cylindrical specimen. The problem of the theory of elasticity for a cylinder is solved using Muskhelishvili's method. In this method, the displacements and stresses are represented in terms of two analytical functions of a complex variable. In the main approaches, the nonlinear interaction between the loading bearing blocks and the specimen as well as the curvature of their surfaces and the elastic parameters of their materials are taken into account. Numerical examples are solved using MATLAB to demonstrate the influence of deformability, curvature of the specimen and platens on the distribution of the normal contact stresses as well as on the tensile and compressive stresses acting across the loaded diameter. Derived equations also allow calculating the modulus of elasticity, total deformation modulus and creep parameters of the specimen material based on the experimental data of radial contraction of the specimen.

  15. A curved beam test specimen for determining the interlaminar tensile strength of a laminated composite

    Science.gov (United States)

    Hiel, Clement C.; Sumich, Mark; Chappell, David P.

    1991-01-01

    A curved beam type of test specimen is evaluated for use in determining the through-the-thickness strength of laminated composites. Two variations of a curved beam specimen configuration (semicircular and elliptical) were tested to failure using static and fatigue loads. The static failure load for the semicircular specimens was found to be highly sensitive to flaw content, with the specimens falling into two distinct groups. This result supports the use of proof testing for structural validation. Static design allowables are derived based on the Weibull distribution. Fatigue data indicates no measured increase in specimen compliance prior to final fracture. All static and fatigue failures at room temperature dry conditions occurred catastrophically. The elliptical specimens demonstrated unusually high failure strengths indicating the presence of phenomena requiring further study. Results are also included for specimens exposed to a wet environment showing a matrix strength degradation due to moisture content. Further testing is underway to evaluate a fatigue methodology for matrix dominated failures based on residual static strength (wearout).

  16. TEST FUSION IN ADULT FORAMINIFERA: A REVIEW WITH NEW OBSERVATIONS OF AN EARLY EOCENE NUMMULITES SPECIMEN

    Science.gov (United States)

    Ferràndez-Cañadell, Carles; Briguglio, Antonino; Hohenegger, Johann; Wöger, Julia

    2015-01-01

    In foraminifera, so-called “double tests” usually arise due to abnormal growth originating mainly from twinning, but may also be caused by irregularities in the early chambers and by regeneration after test injury that modifies the direction of growth. A fourth cause of double tests has only rarely been reported: the fusion of the tests of two adult individuals. We studied an early Eocene Nummulites double test consisting of two adult individuals that fused after an extended period of independent growth. The specimen was studied using computed tomography with micrometric resolution (micro-CT) that allowed bi- and three-dimensional visualization of the internal structure. Before fusion each individual test had 30–36 chambers, which, by comparison with growth rates in recent nummulitids, implies at least three months of independent growth. After fusion, the compound test grew in two spirals that fused after about one whorl and then continued in a single spiral. To fuse their tests, either adult individuals have to be forced to do so or the allorecognition (ability to distinguish between self and another individual) mechanisms must fail. A possible explanation for the merged Nummulites tests in this study is forced fusion in attached individuals after surviving ingestion and digestion by a metazoan. Alternatively, environmental stress could lead to a failure of allorecognition mechanisms and/or foraminiferal motility. Once fused, subsequent growth seems to be determined mainly by the relative orientation of individual tests. In any case, the frequency in which adult fusion occurs remains unknown. PMID:26166916

  17. C.O.D. toughness testing of medium strength steel as a preliminary development for single specimen J integral toughness tests of SA533-B steel

    International Nuclear Information System (INIS)

    Dean, P.; Tait, R.B.; Garrett, G.G.

    1981-10-01

    The primary purpose of this project is to set up a test facility and to develop the necessary expertise to enable reliable elasto-plastic fracture toughness tests to be performed. Initially, tests are to be conducted on material similar to that used in the Koeberg pressure vessel walls, with the ultimate goal of performing single specimen J integral tests on the pressure vessel steel itself to determine through-thickness toughness variations. The project will comprise a number of stages, each one necessary for the development of the techniques used in J integral testing. These include: (i) development of an appropriate specimen design, of suitable size and shape that is applicable to both crack opening displacement (C.O.D.) and J integral tests; (ii) development, testing and calibration of the necessary associated mechanical and electrical equipment (e.g. clip gauge, amplifiers, interface unit, etc.), with (iii) an estimation of the probable errors and noise levels with a view to their elimantion, leading to (iv) perfection of the sensitivity and reproducibility of, firstly, the multiple specimen C.O.D. technique and, secondly, the multiple specimen J integral techniques. (v) Based on the above techniques, development of the single specimen J integral test method incorporating development of a computerised testing procedure. All the above procedure is to be conducted on similar, but non-Koeberg pressure vessel material ('ROQ Tough'). (vi) Finally, development and testing of both multiple specimen and single specimen J integral tests on actual SA533B material and an investigation of the through thickness toughness and fatigue crack propagation behaviour

  18. Fracture toughness evaluation using circumferential notched tensile specimens by the tensile test and ANSYS software

    Energy Technology Data Exchange (ETDEWEB)

    Meydanlik, N. [Mechanical Engineering Department, Trakya University, Edirne (Turkey)

    2013-07-01

    Fracture toughness (K{sub Ic} ) is the most important parameter that defines mechanical behaviour of the materials using machine design. Since, fracture tests are both difficult and time consuming, the researchers have been investigating for the easier evaluation of K{sub Ic} for many years. In this work; K{sub Ic} values have been obtained by using ANSYS software based on the experimental values evaluated in the previous studies. It was shown that there is no significant difference between the experimental ones and the ones obtained by ANSYS. This procedure can provide an important advantage on obtaining of the K{sub IC} values. Key words: Fracture toughness (K{sub Ic} ), circumferential notched tensile specimens, ANSYS.

  19. Test of large-scale specimens and models as applied to NPP equipment materials

    International Nuclear Information System (INIS)

    Timofeev, B.T.; Karzov, G.P.

    1993-01-01

    The paper presents the test results on low-cycle fatigue, crack growth rate and fracture toughness of large-scale specimens and structures, manufactured from steel, widely applied in power engineering industry and used for the production of NPP equipment with VVER-440 and VVER-1000 reactors. The obtained results are compared with available test results of standard specimens and calculation relations, accepted in open-quotes Calculation Norms on Strength.close quotes At the fatigue crack initiation stage the experiments were performed on large-scale specimens of various geometry and configuration, which permitted to define 15X2MFA steel fracture initiation resistance by elastic-plastic deformation of large material volume by homogeneous and inhomogeneous state. Besides the above mentioned specimen tests in the regime of low-cycle loading, the test of models with nozzles were performed and a good correlation of the results on fatigue crack initiation criterium was obtained both with calculated data and standard low-cycle fatigue tests. It was noted that on the Paris part of the fatigue fracture diagram a specimen thickness increase does not influence fatigue crack growth resistance by tests in air both at 20 and 350 degrees C. The estimation of the comparability of the results, obtained on specimens and models was also carried out for this stage of fracture. At the stage of unstable crack growth by static loading the experiments were conducted on specimens of various thickness for 15X2MFA and 15X2NMFA steels and their welded joints, produced by submerged arc welding, in as-produced state (the beginning of service) and after embrittling heat treatment, simulating neutron fluence attack (the end of service). The obtained results give evidence of the possibility of the reliable prediction of structure elements brittle fracture using fracture toughness test results on relatively small standard specimens. 35 refs., 23 figs

  20. Development of European creep crack growth testing code of practice for industrial specimens

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, B.; Nikbin, K. [Imperial College, London (United Kingdom); Petrovski, B. [Technische Univ. Darmstadt (DE). Inst. fuer Werkstoffkunde (IFW)

    2004-07-01

    The integrity and residual life assessment of high temperature components require defects, detected or assumed to exist, through minimum allowable limits of detectable flaws using nondestructive testing methods. It relies on information obtained from the material's mechanical, uniaxial creep, creep crack initiation and growth properties. The information derived from experiments needs to be validated and harmonised following a Code of Practice that data variability between different institutions can be reduced to a minimum. The present paper reports on a Code of Practice (CoP) being prepared within the framework of the partially European Commission funded project CRETE. The novel aspect of the presented CoP is the inclusion of component relevant industrial specimen geometries. It covers testing and analysis of Creep Crack growth (CCG) in metallic materials at elevated temperature using six different cracked geometries that have been validated in. It aims to give advice on testing, measurements and analysis of creep crack growth data for a range of creep brittle to creep ductile materials using component service relevant specimen geometries and sizes. The CoP may be used for material selection criteria and inspection requirements for damage tolerant applications. In quantitative terms, these types of tests can be used to assess the individual and combined effects of metallurgical, fabrication, operating temperature, and loading conditions on creep crack growth life. Further issues will be addressed including material properties, damage and crack growth related constraint effect, stress relaxation and stress-strain fields, residual stresses, partitioning displacement, analysis of elasticcreep, elastic compliance measurements.

  1. Standard practice for preparation and use of direct tension stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This practice covers procedures for designing, preparing, and using ASTM standard tension test specimens for investigating susceptibility to stress-corrosion cracking. Axially loaded specimens may be stressed quantitatively with equipment for application of either a constant load, constant strain, or with a continuously increasing strain. 1.2 Tension test specimens are adaptable for testing a wide variety of product forms as well as parts joined by welding, riveting, or various other methods. 1.3 The exposure of specimens in a corrosive environment is treated only briefly because other standards are being prepared to deal with this aspect. Meanwhile, the investigator is referred to Practices G35, G36, G37, and G44, and to ASTM Special Technical Publication 425 (1).

  2. Testing machine for fatigue crack kinetic investigation in specimens under bending

    International Nuclear Information System (INIS)

    Panasyuk, V.V.; Ratych, L.V.; Dmytrakh, I.N.

    1978-01-01

    A kinematic diagram of testing mashine for the investigation of fatigue crack kinetics in prismatic specimens, subjected to pure bending is described. Suggested is a technique of choosing an optimum ratio of the parameters of ''the testing machine-specimen'' system, which provide the stabilization of the stress intensity coefficient for a certain region of crack development under hard loading. On the example of the 40KhS and 15Kh2MFA steel specimens the pliability of the machine constructed according to the described diagram and designed for the 30ONxm maximum bending moment. The results obtained can be used in designing of the testing machines for studying pure bending under hard loading and in choosing the sizes of specimens with rectangular cross sections for investigations into the kinetics of the fatigue crack

  3. An Upgrade Pinning Block: A Mechanical Practical Aid for Fast Labelling of the Insect Specimens.

    Science.gov (United States)

    Ghafouri Moghaddam, Mohammad Hossein; Ghafouri Moghaddam, Mostafa; Rakhshani, Ehsan; Mokhtari, Azizollah

    2017-01-01

    A new mechanical innovation is described to deal with standard labelling of dried specimens on triangular cards and/or pinned specimens in personal and public collections. It works quickly, precisely, and easily and is very useful for maintaining label uniformity in collections. The tools accurately sets the position of labels in the shortest possible time. This tools has advantages including rapid processing, cost effectiveness, light weight, and high accuracy, compared to conventional methods. It is fully customisable, compact, and does not require specialist equipment to assemble. Conventional methods generally require locating holes on the pinning block surface when labelling with a resulting risk to damage of the specimens. Insects of different orders can be labelled by this simple and effective tool.

  4. Design, Fabrication and Test Report on a Verification Capsule (05M-06K) for the Control of a Neutron Irradiation Fluence of Specimens in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Choo, K. N.; Kim, B. G.; Kang, Y. H.; Cho, M. S.; Son, J. M.; Shin, Y. T.; Park, S. J.; Choi, M. H.; Lee, D. S.

    2007-02-15

    As a part of a project for a capsule development and utilization for an irradiation test, a verification capsule (05M-06K) was designed, fabricated and tested for the development of new instrumented capsule technology for a more precise control of the irradiation fluence of a specimen, irrespective of the reactor operation condition. The basic structure of the 05M-06K capsule was based on the 04M-22K mock-up capsule which was successfully designed and out-pile tested to confirm the various key technologies necessary for the fluence control of a specimen. 21 square and round shaped specimens made of STS 304 were inserted into the capsule. The capsule was constructed in 5 stages with specimens and an independent electric heater at each stage. Each of the five specimens which were accommodated in the 1st stage (top) of the capsule can be taken out of the HANARO core during a normal reactor operation. The specimen is extracted by a specimen extraction mechanism using a steel wire. During the out-pile test, the temperatures of the specimens were measured by 12 thermocouples installed in the capsule. The capsule was successfully out-pile tested in a single channel test loop. The obtained results will be used for a safety evaluation of the new irradiation capsule for controlling the irradiation fluence of specimens in HANARO.

  5. 49 CFR 40.99 - How long does the laboratory retain specimens after testing?

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false How long does the laboratory retain specimens after testing? 40.99 Section 40.99 Transportation Office of the Secretary of Transportation PROCEDURES FOR TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Drug Testing Laboratories § 40.99 How...

  6. Standard practice for fracture testing with surface-crack tension specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers the design, preparation, and testing of surface-crack tension (SCT) specimens. It relates specifically to testing under continuously increasing force and excludes cyclic and sustained loadings. The quantity determined is the residual strength of a specimen having a semielliptical or circular-segment fatigue crack in one surface. This value depends on the crack dimensions and the specimen thickness as well as the characteristics of the material. 1.2 Metallic materials that can be tested are not limited by strength, thickness, or toughness. However, tests of thick specimens of tough materials may require a tension test machine of extremely high capacity. The applicability of this practice to nonmetallic materials has not been determined. 1.3 This practice is limited to specimens having a uniform rectangular cross section in the test section. The test section width and length must be large with respect to the crack length. Crack depth and length should be chosen to suit the ultimate pu...

  7. Creep-fatigue assessment of a thermina test specimen using the R5 procedure

    International Nuclear Information System (INIS)

    Booth, P.; Budden, P.J.; Bate, S.K.

    1997-01-01

    A creep-fatigue life assessment of an axisymmetric 316 stainless steel test specimen under constant mechanical and cyclic thermal shock loading using the R5 Procedure is described in this paper. This test was carried out at CEA, France, and formed part of the 'Thermina' series. Stress analysis has been carried out using both full inelastic finite element analysis and also the simplified shakedown methods, based on elastic calculation, within R5. The estimates of strain range and the stress at the start of the creep dwell have then been used with R5 to estimate creep and fatigue damage per cycle and hence to make predictions of component life. The predicted lives are compared with the lives observed in the tests. The simplified R5 estimate of life, based on development of a crack of depth 200 microns, is 260 cycles using best-estimate material properties. Experimentally, cracks of depth at least 150 microns were observed in between 526 and 650 cycles, for two similar tests. The simplified R5 route therefore leads to an estimate of life which is conservative but not unduly so on this component. Detailed cyclic inelastic analysis using the ORNL constitutive model and the ABAQUS finite element code to estimate the strain range and dwell stress led to a best estimate of 618 cycles to crack initiation using R5. (author). 16 refs, 11 figs, 4 tabs

  8. Additive Manufacturing of Syntactic Foams: Part 2: Specimen Printing and Mechanical Property Characterization

    Science.gov (United States)

    Singh, Ashish Kumar; Saltonstall, Brooks; Patil, Balu; Hoffmann, Niklas; Doddamani, Mrityunjay; Gupta, Nikhil

    2018-03-01

    High-density polyethylene (HDPE) and its fly ash cenosphere-filled syntactic foam filaments have been recently developed. These filaments are used for three-dimensional (3D) printing using a commercial printer. The developed syntactic foam filament (HDPE40) contains 40 wt.% cenospheres in the HDPE matrix. Printing parameters for HDPE and HDPE40 were optimized for use in widely available commercial printers, and specimens were three-dimensionally (3D) printed for tensile testing at strain rate of 10-3 s-1. Process optimization resulted in smooth operation of the 3D printer without nozzle clogging or cenosphere fracture during the printing process. Characterization results revealed that the tensile modulus values of 3D-printed HDPE and HDPE40 specimens were higher than those of injection-molded specimens, while the tensile strength was comparable, but the fracture strain and density were lower.

  9. Evaluation of Specimen Geometric Effect for Laser Flash Thermal Diffusivity Test

    International Nuclear Information System (INIS)

    Park, Dae Gyu; Kim, Hee Moon; Song, Woong Sub; Baik, Seung Je; Ryu, Woo Seok; Ahn, Sang Bok; Joo, Young Sun

    2012-01-01

    KAERI(Korea Atomic Energy Research Institute) is developing a new type of nuclear reactor, the so called 'SMART' (System Integrated Modular Advanced Reactor) reactor. Alloy 690 was selected as the candidate material for the heat exchanger tube of of SMART's steam generator. The SMART R and D is now facing the stage of engineering verification and standard design approval for application of DEMO reactors. Therefore, the material performance under the relevant environment needs to be evaluated. The one of the important material performance issues is thermal conductivity, which the engineering database is necessary for the steam generator design. However, the neutron post irradiation characteristics of alloy 690 are little known. As a result, a PIE (Post Irradiation Examination) of the thermal properties have been plan for a 4 times, so called base line test, 1 st irradiation test, 2 nd and 3 rd irradiation test. But there is some constraint to perform thermal diffusivity test owing to test specimen. Originally thermal diffusivity test are planed using disk shape with 9 mm diameter and 1 mm thick specimen. Due to mismatch of neutron irradiation schedule, thermal diffusivity will be tested by different shape and size specimens at 1 st irradiation test. Therefore, verification of geometric and size effect are necessary for test specimen in order to achieve accurate test results

  10. Mechanical Properties Analysis of 4340 Steel Specimen Heat Treated in Oven and Quenching in Three Different Fluids

    Science.gov (United States)

    Fakir, Rachid; Barka, Noureddine; Brousseau, Jean

    2018-03-01

    This paper proposes a statistical approach to analyze the mechanical properties of a standard test specimen, of cylindrical geometry and in steel 4340, with a diameter of 6 mm, heat-treated and quenched in three different fluids. Samples were evaluated in standard tensile test to access their characteristic quantities: hardness, modulus of elasticity, yield strength, tensile strength and ultimate deformation. The proposed approach is gradually being built (a) by a presentation of the experimental device, (b) a presentation of the experimental plan and the results of the mechanical tests, (c) anova analysis of variance and a representation of the output responses using the RSM response surface method, and (d) an analysis of the results and discussion. The feasibility and effectiveness of the proposed approach leads to a precise and reliable model capable of predicting the variation of mechanical properties, depending on the tempering temperature, the tempering time and the cooling capacity of the quenching medium.

  11. Relationships between Loblolly Pine small clear specimens and Dimension Lumber Tested in Static Bending

    Science.gov (United States)

    Mark Alexander Butler; Joseph Dahlen; Finto Antony; Michael Kane; Thomas L. Eberhardt; Huizhe Jin; Kim Love-Myers; John Paul McTague

    2016-01-01

    Prior to the 1980s, the allowable stresses for lumber in North America were derived from testing of small clear specimens. However, the procedures were changed because these models were found to be inaccurate. Nevertheless, small clear testing continues to be used around the world for allowable stress determinations and in studies that examine forest management impacts...

  12. Influence of Specimen Preparation and Test Methods on the Flexural Strength Results of Monolithic Zirconia Materials.

    Science.gov (United States)

    Schatz, Christine; Strickstrock, Monika; Roos, Malgorzata; Edelhoff, Daniel; Eichberger, Marlis; Zylla, Isabella-Maria; Stawarczyk, Bogna

    2016-03-09

    The aim of this work was to evaluate the influence of specimen preparation and test method on the flexural strength results of monolithic zirconia. Different monolithic zirconia materials (Ceramill Zolid (Amann Girrbach, Koblach, Austria), Zenostar ZrTranslucent (Wieland Dental, Pforzheim, Germany), and DD Bio zx² (Dental Direkt, Spenge, Germany)) were tested with three different methods: 3-point, 4-point, and biaxial flexural strength. Additionally, different specimen preparation methods were applied: either dry polishing before sintering or wet polishing after sintering. Each subgroup included 40 specimens. The surface roughness was assessed using scanning electron microscopy (SEM) and a profilometer whereas monoclinic phase transformation was investigated with X-ray diffraction. The data were analyzed using a three-way Analysis of Variance (ANOVA) with respect to the three factors: zirconia, specimen preparation, and test method. One-way ANOVA was conducted for the test method and zirconia factors within the combination of two other factors. A 2-parameter Weibull distribution assumption was applied to analyze the reliability under different testing conditions. In general, values measured using the 4-point test method presented the lowest flexural strength values. The flexural strength findings can be grouped in the following order: 4-point strength values than prepared before sintering. The Weibull moduli ranged from 5.1 to 16.5. Specimens polished before sintering showed higher surface roughness values than specimens polished after sintering. In contrast, no strong impact of the polishing procedures on the monoclinic surface layer was observed. No impact of zirconia material on flexural strength was found. The test method and the preparation method significantly influenced the flexural strength values.

  13. Remote replacement of materials open-test assembly specimens at the FFTF/IEM cell

    International Nuclear Information System (INIS)

    Gibbons, P.W.; Ramsey, E.B.

    1990-01-01

    The Fast Flux Test Facility (FFTF) interim examination and maintenance (IEM) cell is used for the remote disassembly of irradiated fuel and materials experiments. The materials open-test assembly (MOTA) is brought to the IEM cell for materials test specimen removal. The specimens are shipped to the materials laboratory for sorting and installation in new specimen holders and then returned within 10 days to the IEM cell where they are installed in a new MOTA vehicle for further irradiation. Reconstituting a MOTA is a challenging remote operation involving dozens of steps and two separate facilities. Handling and disassembling sodium-wetted components pose interesting handling, cleaning, and disposal challenges. The success of this system is evidenced by its timely completion in the critical path of FFTF outage schedules

  14. Void coalescence and fracture behavior of notched and un-notched tensile tested specimens in fine grain dual phase steel

    Energy Technology Data Exchange (ETDEWEB)

    Saeidi, N., E-mail: navidsae@gmail.com [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Ashrafizadeh, F.; Niroumand, B. [Department of Materials Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Forouzan, M.R.; Mohseni mofidi, S. [Department of Mechanical Engineering, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of); Barlat, F. [Materials Mechanics Laboratory (MML), Graduate Institute of Ferrous Technology (GIFT), Pohang University of Science and Technology POSTECH, San 31 Hyoja-dong, Nam-gu, Pohang, Gyeongbuk 790-784 (Korea, Republic of)

    2015-09-17

    Due to growing global concern about the environmental issues, steel developers have been forced by automobile makers to produce more efficient steel grades with high strength to weight ratios along with high crashworthiness performance. In order to find deficiencies of the existing steels and develop superior steel products, detailed understanding of deformation and damage behavior in the existing steels is needed. In the present research, deformation and damage evolution during room temperature uniaxial tensile test of a modern high strength Dual Phase Steel, i.e. DP780, were studied. Detailed scanning electron microscopy (SEM) examination of the microstructures of notched and un-notched tensile fractured specimens revealed that in notched specimen, plastic deformation was concentrated more within the notched region. Therefore, much higher reduction in thickness with a high reduction gradient occurred in this region, In the un-notched specimen, however, plastic deformation was more uniformly distributed in larger parts of the gauge length, and therefore, thickness reduction happened with a lower gradient. Although geometric notch on the specimen did not change the void nucleation and growth mechanisms, the kinetics of these phenomena was influenced. On the other hand, voids linkage mechanism tended to change from void coalescence in the un-notched specimen to void sheeting in the notched specimen. Moreover, three different models developed by Brown & Embury (BM), Thomason and Pardoen were employed to predict the final fracture strain. It was revealed that, BM model showed much more accurate predictions for the studied DP steel in comparison with those of Thomason and Pardoens’ models.

  15. Void coalescence and fracture behavior of notched and un-notched tensile tested specimens in fine grain dual phase steel

    International Nuclear Information System (INIS)

    Saeidi, N.; Ashrafizadeh, F.; Niroumand, B.; Forouzan, M.R.; Mohseni mofidi, S.; Barlat, F.

    2015-01-01

    Due to growing global concern about the environmental issues, steel developers have been forced by automobile makers to produce more efficient steel grades with high strength to weight ratios along with high crashworthiness performance. In order to find deficiencies of the existing steels and develop superior steel products, detailed understanding of deformation and damage behavior in the existing steels is needed. In the present research, deformation and damage evolution during room temperature uniaxial tensile test of a modern high strength Dual Phase Steel, i.e. DP780, were studied. Detailed scanning electron microscopy (SEM) examination of the microstructures of notched and un-notched tensile fractured specimens revealed that in notched specimen, plastic deformation was concentrated more within the notched region. Therefore, much higher reduction in thickness with a high reduction gradient occurred in this region, In the un-notched specimen, however, plastic deformation was more uniformly distributed in larger parts of the gauge length, and therefore, thickness reduction happened with a lower gradient. Although geometric notch on the specimen did not change the void nucleation and growth mechanisms, the kinetics of these phenomena was influenced. On the other hand, voids linkage mechanism tended to change from void coalescence in the un-notched specimen to void sheeting in the notched specimen. Moreover, three different models developed by Brown & Embury (BM), Thomason and Pardoen were employed to predict the final fracture strain. It was revealed that, BM model showed much more accurate predictions for the studied DP steel in comparison with those of Thomason and Pardoens’ models

  16. Small Scale Yielding Correction of Constraint Loss in Small Sized Fracture Toughness Test Specimens

    International Nuclear Information System (INIS)

    Kim, Maan Won; Kim, Min Chul; Lee, Bong Sang; Hong, Jun Hwa

    2005-01-01

    Fracture toughness data in the ductile-brittle transition region of ferritic steels show scatter produced by local sampling effects and specimen geometry dependence which results from relaxation in crack tip constraint. The ASTM E1921 provides a standard test method to define the median toughness temperature curve, so called Master Curve, for the material corresponding to a 1T crack front length and also defines a reference temperature, T 0 , at which median toughness value is 100 MPam for a 1T size specimen. The ASTM E1921 procedures assume that high constraint, small scaling yielding (SSY) conditions prevail at fracture along the crack front. Violation of the SSY assumption occurs most often during tests of smaller specimens. Constraint loss in such cases leads to higher toughness values and thus lower T 0 values. When applied to a structure with low constraint geometry, the standard fracture toughness estimates may lead to strongly over-conservative estimates. A lot of efforts have been made to adjust the constraint effect. In this work, we applied a small-scale yielding correction (SSYC) to adjust the constraint loss of 1/3PCVN and PCVN specimens which are relatively smaller than 1T size specimen at the fracture toughness Master Curve test

  17. Experimental and Numerical Evaluation of Direct Tension Test for Cylindrical Concrete Specimens

    Directory of Open Access Journals (Sweden)

    Jung J. Kim

    2014-01-01

    Full Text Available Concrete cracking strength can be defined as the tensile strength of concrete subjected to pure tension stress. However, as it is difficult to apply direct tension load to concrete specimens, concrete cracking is usually quantified by the modulus of rupture for flexural members. In this study, a new direct tension test setup for cylindrical specimens (101.6 mm in diameter and 203.2 mm in height similar to those used in compression test is developed. Double steel plates are used to obtain uniform stress distributions. Finite element analysis for the proposed test setup is conducted. The uniformity of the stress distribution along the cylindrical specimen is examined and compared with rectangular cross section. Fuzzy image pattern recognition method is used to assess stress uniformity along the specimen. Moreover, the probability of cracking at different locations along the specimen is evaluated using probabilistic finite element analysis. The experimental and numerical results of the cracking location showed that gravity effect on fresh concrete during setting time might affect the distribution of concrete cracking strength along the height of the structural elements.

  18. Computer vision applied to herbarium specimens of German trees: testing the future utility of the millions of herbarium specimen images for automated identification.

    Science.gov (United States)

    Unger, Jakob; Merhof, Dorit; Renner, Susanne

    2016-11-16

    Global Plants, a collaborative between JSTOR and some 300 herbaria, now contains about 2.48 million high-resolution images of plant specimens, a number that continues to grow, and collections that are digitizing their specimens at high resolution are allocating considerable recourses to the maintenance of computer hardware (e.g., servers) and to acquiring digital storage space. We here apply machine learning, specifically the training of a Support-Vector-Machine, to classify specimen images into categories, ideally at the species level, using the 26 most common tree species in Germany as a test case. We designed an analysis pipeline and classification system consisting of segmentation, normalization, feature extraction, and classification steps and evaluated the system in two test sets, one with 26 species, the other with 17, in each case using 10 images per species of plants collected between 1820 and 1995, which simulates the empirical situation that most named species are represented in herbaria and databases, such as JSTOR, by few specimens. We achieved 73.21% accuracy of species assignments in the larger test set, and 84.88% in the smaller test set. The results of this first application of a computer vision algorithm trained on images of herbarium specimens shows that despite the problem of overlapping leaves, leaf-architectural features can be used to categorize specimens to species with good accuracy. Computer vision is poised to play a significant role in future rapid identification at least for frequently collected genera or species in the European flora.

  19. Quantifying dynamic mechanical properties of human placenta tissue using optimization techniques with specimen-specific finite-element models.

    Science.gov (United States)

    Hu, Jingwen; Klinich, Kathleen D; Miller, Carl S; Nazmi, Giseli; Pearlman, Mark D; Schneider, Lawrence W; Rupp, Jonathan D

    2009-11-13

    Motor-vehicle crashes are the leading cause of fetal deaths resulting from maternal trauma in the United States, and placental abruption is the most common cause of these deaths. To minimize this injury, new assessment tools, such as crash-test dummies and computational models of pregnant women, are needed to evaluate vehicle restraint systems with respect to reducing the risk of placental abruption. Developing these models requires accurate material properties for tissues in the pregnant abdomen under dynamic loading conditions that can occur in crashes. A method has been developed for determining dynamic material properties of human soft tissues that combines results from uniaxial tensile tests, specimen-specific finite-element models based on laser scans that accurately capture non-uniform tissue-specimen geometry, and optimization techniques. The current study applies this method to characterizing material properties of placental tissue. For 21 placenta specimens tested at a strain rate of 12/s, the mean failure strain is 0.472+/-0.097 and the mean failure stress is 34.80+/-12.62 kPa. A first-order Ogden material model with ground-state shear modulus (mu) of 23.97+/-5.52 kPa and exponent (alpha(1)) of 3.66+/-1.90 best fits the test results. The new method provides a nearly 40% error reduction (p<0.001) compared to traditional curve-fitting methods by considering detailed specimen geometry, loading conditions, and dynamic effects from high-speed loading. The proposed method can be applied to determine mechanical properties of other soft biological tissues.

  20. The detection of tightly closed flaws by nondestructive testing (NDT) methods. [fatigue crack formation in aluminum alloy test specimens

    Science.gov (United States)

    Rummel, W. D.; Rathke, R. A.; Todd, P. H., Jr.; Mullen, S. J.

    1975-01-01

    Liquid penetrant, ultrasonic, eddy current and X-radiographic techniques were optimized and applied to the evaluation of 2219-T87 aluminum alloy test specimens in integrally stiffened panel, and weld panel configurations. Fatigue cracks in integrally stiffened panels, lack-of-fusion in weld panels, and fatigue cracks in weld panels were the flaw types used for evaluation. A 2319 aluminum alloy weld filler rod was used for all welding to produce the test specimens. Forty seven integrally stiffened panels containing a total of 146 fatigue cracks, ninety three lack-of-penetration (LOP) specimens containing a total of 239 LOP flaws, and one-hundred seventeen welded specimens containing a total of 293 fatigue cracks were evaluated. Nondestructive test detection reliability enhancement was evaluated during separate inspection sequences in the specimens in the 'as-machined or as-welded', post etched and post proof loaded conditions. Results of the nondestructive test evaluations were compared to the actual flaw size obtained by measurement of the fracture specimens after completing all inspection sequences. Inspection data were then analyzed to provide a statistical basis for determining the flaw detection reliability.

  1. The distinct element analysis for swelling pressure test of bentonite. Discussion on the effects of wall friction force and aspect ratio of specimen

    International Nuclear Information System (INIS)

    Shimizu, Hiroyuki; Kikuchi, Hirohito; Fujita, Tomoo; Tanai, Kenji

    2011-10-01

    For geological isolation systems for radioactive waste, bentonite based material is assumed to be used as a buffer material. The swelling characteristics of the bentonite based material are expected to fill up the void space around the radioactive wastes by swelling. In general, swelling characteristics and properties of bentonite are evaluated by the laboratory tests. However, due to the lack of standardization of testing method for bentonite, the accuracy and reproducibility of the testing results are not sufficiently proved. In this study, bentonite swelling pressure test were simulated by newly developed Distinct Element Method (DEM) code, and the effects of wall friction force and aspect ratio of bentonite specimen were discussed. As a result, the followings were found. In the beginning of the swelling pressure test, since swelling occurs only around the fluid injection side of the specimen, wall friction force acts only in the swelling area and the specimen moves to opposite side from fluid injection side. However, when the entire specimen started swelling, displacement of the specimen prevented by the wall friction force, and the specimen is pressed against the pressure measurement side. Then, the swelling pressure measured on the pressure measurement side increases. Such displacement in the specimen is significantly affected by the decreasing of mechanical properties and the difference of saturation in the bentonite specimen during the fluid infiltration. Moreover, when the aspect ratio of the specimen is large, the displacement of the particle in the specimen becomes large and the area on which the wall frictional force acts is also large. Therefore, measured swelling pressure increases more greatly as the aspect ratio of the specimen increases. To contributes to the standardization of laboratory test methods for bentonite, these effects of wall friction force revealed by the DEM simulation should be verified through laboratory experiments. (author)

  2. COMPARISON BETWEEN WOOD DRYING DEFECT SCORES: SPECIMEN TESTING X ANALYSIS OF KILN-DRIED BOARDS

    Directory of Open Access Journals (Sweden)

    Djeison Cesar Batista

    2015-04-01

    Full Text Available It is important to develop drying technologies for Eucalyptus grandis lumber, which is one of the most planted species of this genus in Brazil and plays an important role as raw material for the wood industry. The general aim of this work was to assess the conventional kiln drying of juvenile wood of three clones of Eucalyptus grandis. The specific aims were to compare the behavior between: i drying defects indicated by tests with wood specimens and conventional kiln-dried boards; and ii physical properties and the drying quality. Five 11-year-old trees of each clone were felled, and only flatsawn boards of the first log were used. Basic density and total shrinkage were determined, and the drying test with wood specimens at 100 °C was carried out. Kiln drying of boards was performed, and initial and final moisture content, moisture gradient in thickness, drying stresses and drying defects were assessed. The defect scoring method was used to verify the behavior between the defects detected by specimen testing and the defects detected in kiln-dried boards. As main results, the drying schedule was too severe for the wood, resulting in a high level of boards with defects. The behavior between the defects in the drying test with specimens and the defects of kiln-dried boards was different, there was no correspondence, according to the defect scoring method.

  3. Stress corrosion cracking tests on electron beam welded carbon steel specimens in carbonate-bicarbonate solution

    International Nuclear Information System (INIS)

    Parkins, R.N.

    1985-04-01

    Stress corrosion cracking tests have been performed on tapered carbon steel test pieces containing electron beam welds with a view to defining susceptibility to such cracking in a carbonate-bicarbonate solution at 90 C and an appropriate electrode potential. The tests involved applying cyclic loads to the specimens and it is shown that the threshold stress for cracking reduces linearly with increase in the magnitude of the cyclic load component. Extrapolation of these trends to zero fluctuating stress indicates static load threshold stresses in the vicinity of the yield stress (i.e. about 300 N/mm 2 for parent plate without a weld, 400 N/mm 2 for specimens with welds on one side only and 600 N/mm 2 for specimens having welds penetrating through the thickness of the specimen). The averages of the maximum crack velocities observed were least for parent plate material and greatest for weld metal, the former being essentially intergranular in morphology and the latter mostly transgranular, with heat affected zone material being intermediate between these extremes. (author)

  4. Analysis of the percentage voids of test and field specimens using computerized tomography

    International Nuclear Information System (INIS)

    Braz, D.; Lopes, R.T.; Motta, L.M.G. da

    1999-01-01

    Computerized tomography has been an excellent tool of analysis of asphaltics mixtures, because it allows comparison of the quality and integrity of test and field specimens. It was required to detect and follow the evolution of cracks, when these mixtures were submitted to fatigue tests, and also helping to interpret the distribution of tensions and deformations which occur in the several types of solicitations imposed to the mixtures. Comparing the medium values of percentage voids obtained from tomographic images with the project's values, it can be observed that the values of test and field specimens for the wearing course are closer to the ones of the project than the ones of the binder. It can be verified that the wearing course specimens always present a distribution of the aggregate, and voids quite homogeneously in the whole profile of the sample, while the binder specimens show an accentuated differentiation of the same factors in the several heights of the sample. Therefore, when choosing a slice for tomography, these considerations should be taken into account

  5. Method for independent strain and temperature measurement in polymeric tensile test specimen using embedded FBG sensors

    DEFF Research Database (Denmark)

    Pereira, Gilmar Ferreira; McGugan, Malcolm; Mikkelsen, Lars Pilgaard

    2016-01-01

    to calculate independently the strain and temperature are presented in the article, together with a measurement resolution study. This multi-parameter measurement method was applied to an epoxy tensile specimen, tested in a unidirectional tensile test machine with a temperature controlled cabinet. A full......A novel method to obtain independent strain and temperature measurements using embedded Fibre Bragg Grating (FBG) in polymeric tensile test specimens is presented in this paper. The FBG strain and temperature cross-sensitivity was decoupled using two single mode FBG sensors, which were embedded...... of temperature, from 40 C to -10 C. The consistency of the expected theoretical results with the calibration procedure and the experimental validation shows that this proposed method is applicable to measure accurate strain and temperature in polymers during static or fatigue tensile testing. Two different...

  6. Testing Nonassociative Quantum Mechanics.

    Science.gov (United States)

    Bojowald, Martin; Brahma, Suddhasattwa; Büyükçam, Umut

    2015-11-27

    The familiar concepts of state vectors and operators in quantum mechanics rely on associative products of observables. However, these notions do not apply to some exotic systems such as magnetic monopoles, which have long been known to lead to nonassociative algebras. Their quantum physics has remained obscure. This Letter presents the first derivation of potentially testable physical results in nonassociative quantum mechanics, based on effective potentials. They imply new effects which cannot be mimicked in usual quantum mechanics with standard magnetic fields.

  7. Constructing kinetics fatigue diagrams using testing results obtained on a machine with rigid loading for specimens of various thickness

    International Nuclear Information System (INIS)

    Simin'kovich, V.N.; Gladkij, Ya.N.; Deev, N.A.

    1981-01-01

    Bending tests of 40KhS steel specimens, tempered at 200 and 500 deg C, are conducted to investigate the possible effects of specimen thickness on fatigue crack growth. Kinetic fatigue diagrams are constructed using the investigation results. An increase in crack growth with thickness is observed only in high-tempered specimens. Changes in specimen thickness do not affect crack growth in 40KhS low-tempered steel [ru

  8. SMILE: test to validate the WPS effect with a cylindrical thick-walled specimen

    International Nuclear Information System (INIS)

    Bezdikian, G.; Moinereau, D.; Roos, E.; Kerkhof, K.; Taylor, N.

    2004-01-01

    The Reactor Pressure Vessel (RPV) is an essential component, which is liable to limit the lifetime duration of PWR plants. The assessment of defects in RPV subjected to pressurized thermal shock (PTS) transients made at an European level generally does not necessarily consider the beneficial effect of the load history (Warm Pre-stress, WPS). The SMILE project - Structural Margin Improvements in aged embrittled RPV with Load history Effects - aims to give sufficient elements to demonstrate, to model and to validate the beneficial WPS effect. It also aims to harmonize the different approaches in the national codes and standards regarding the inclusion of the WPS effect in a RPV structural integrity assessment. The project includes significant experimental work on WPS type experiments with C(T) specimens and a PTS type transient experiment on a large component. This paper deals with the results of the PTS type transient experiment on a component-like, specimen subjected to WPS-loading, the so called Validation Test, carried out within the framework of work package WP4. The test specimen consists of a cylindrical thickwalled specimen with a thickness of 40 mm and an outer diameter of 160 mm, provided with an internal fully circumferential crack with a depth of about 15 mm. The specified load path type is Load-Cool-Unload-Fracture (LCUF). (orig.)

  9. Standard practice for preparation and use of Bent-Beam stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2011-01-01

    1.1 This practice covers procedures for designing, preparing, and using bent-beam stress-corrosion specimens. 1.2 Different specimen configurations are given for use with different product forms, such as sheet or plate. This practice applicable to specimens of any metal that are stressed to levels less than the elastic limit of the material, and therefore, the applied stress can be accurately calculated or measured (see Note 1). Stress calculations by this practice are not applicable to plastically stressed specimens. Note 1—It is the nature of these practices that only the applied stress can be calculated. Since stress-corrosion cracking is a function of the total stress, for critical applications and proper interpretation of results, the residual stress (before applying external stress) or the total elastic stress (after applying external stress) should be determined by appropriate nondestructive methods, such as X-ray diffraction (1). 1.3 Test procedures are given for stress-corrosion testing by ex...

  10. Influence Of The Gripping Fixture On The Modified Compact Tension Test Results: Evaluation Of The Experiments On Cylindrical Concrete Specimens

    Directory of Open Access Journals (Sweden)

    Holušová Táňa

    2015-12-01

    Full Text Available The modified compact tension test (MCT might become in the future a stable test configuration for the evaluation of fracture-mechanics parameters or also for description of fatigue behavior of composites materials such as concrete. Core drilling is used for sampling of existing structures. These samples have cylindrical shape with the selected thickness to avoid the stress concentration. This contribution focuses on the evaluation of the fracture behavior during static and quasi static tests. Static tests are performed on standard specimen with diameter 150 mm and length 300 mm. The quasi-static tests are performed using two different gripping fixtures. The results for quasi-static tests are represented as L-COD diagrams (i.e. load vs. crack opening displacement measured on the loading axis. The comparison of results and discussion of advantages and disadvantages are introduced.

  11. Test techniques for fracture mechanics testing

    International Nuclear Information System (INIS)

    Schwalbe, K.H.

    1980-01-01

    Test methods for fracture mechanics tests are described. Two groups of techniques are distinguished: Those for measurement of stable crack growth and those for determination of the loading parameters. (orig.) [de

  12. Quantitative sensing of corroded steel rebar embedded in cement mortar specimens using ultrasonic testing

    Science.gov (United States)

    Owusu Twumasi, Jones; Le, Viet; Tang, Qixiang; Yu, Tzuyang

    2016-04-01

    Corrosion of steel reinforcing bars (rebars) is the primary cause for the deterioration of reinforced concrete structures. Traditional corrosion monitoring methods such as half-cell potential and linear polarization resistance can only detect the presence of corrosion but cannot quantify it. This study presents an experimental investigation of quantifying degree of corrosion of steel rebar inside cement mortar specimens using ultrasonic testing (UT). A UT device with two 54 kHz transducers was used to measure ultrasonic pulse velocity (UPV) of cement mortar, uncorroded and corroded reinforced cement mortar specimens, utilizing the direct transmission method. The results obtained from the study show that UPV decreases linearly with increase in degree of corrosion and corrosion-induced cracks (surface cracks). With respect to quantifying the degree of corrosion, a model was developed by simultaneously fitting UPV and surface crack width measurements to a two-parameter linear model. The proposed model can be used for predicting the degree of corrosion of steel rebar embedded in cement mortar under similar conditions used in this study up to 3.03%. Furthermore, the modeling approach can be applied to corroded reinforced concrete specimens with additional modification. The findings from this study show that UT has the potential of quantifying the degree of corrosion inside reinforced cement mortar specimens.

  13. Standard Practice for Recording Data from Atmospheric Corrosion Tests of Metallic-Coated Steel Specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers a procedure for recording data of atmospheric corrosion tests of metallic-coated steel specimens. Its objective is the assurance of (1) complete identification of materials before testing, (2) objective reporting of material appearance during visual inspections, and (3) adequate photographic, micrographic, and chemical laboratory examinations at specific stages of deterioration, and at the end of the tests. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  14. Computer-aided, single-specimen controlled bending test for fracture-kinetics measurement in ceramics

    International Nuclear Information System (INIS)

    Borovik, V.G.; Chushko, V.M.; Kovalev, S.P.

    1995-01-01

    Fracture testing of ceramics by using controlled crack growth is proposed to allow study of crack-kinetics behavior under a given loading history. A computer-aided, real-time data acquisition system improves the quality of crack-growth parameters obtained in a simple, single-specimen bend test. Several ceramic materials were tested in the present study: aluminum nitride as a linear-elastic material; and alumina and yttria-stabilized zirconia, both representative of ceramics with microstructure-dependent nonlinear fracture properties. Ambiguities in the crack-growth diagrams are discussed to show the importance of accounting for crack-growth history in correctly describing nonequilibrium fracture behavior

  15. Test and Analysis Correlation for a Y-Joint Specimen for a Composite Cryotank

    Science.gov (United States)

    Mason, Brian H.; Sleight, David W.; Grenoble, Ray

    2015-01-01

    The Composite Cryotank Technology Demonstration (CCTD) project under NASA's Game Changing Development Program (GCDP) developed space technologies using advanced composite materials. Under CCTD, NASA funded the Boeing Company to design and test a number of element-level joint specimens as a precursor to a 2.4-m diameter composite cryotank. Preliminary analyses indicated that the y-joint in the cryotank had low margins of safety; hence the y-joint was considered to be a critical design region. The y-joint design includes a softening strip wedge to reduce localized shear stresses at the skirt/dome interface. In this paper, NASA-developed analytical models will be correlated with the experimental results of a series of positive-peel y-joint specimens from Boeing tests. Initial analytical models over-predicted the experimental strain gage readings in the far-field region by approximately 10%. The over-prediction was attributed to uncertainty in the elastic properties of the laminate and a mismatch between the thermal expansion of the strain gages and the laminate. The elastic properties of the analytical model were adjusted to account for the strain gage differences. The experimental strain gages also indicated a large non-linear effect in the softening strip region that was not predicted by the analytical model. This non-linear effect was attributed to delamination initiating in the softening strip region at below 20% of the failure load for the specimen. Because the specimen was contained in a thermally insulated box during cryogenic testing to failure, delamination initiation and progression was not visualized during the test. Several possible failure initiation locations were investigated, and a most likely failure scenario was determined that correlated well with the experimental data. The most likely failure scenario corresponded to damage initiating in the softening strip and delamination extending to the grips at final failure.

  16. Comparison between instrumented precracked Charpy and compact specimen tests of carbon steels

    International Nuclear Information System (INIS)

    Nanstad, R.K.

    1980-01-01

    The General Atomic Company High Temperature Gas-Cooled Reactor (HTGR) is housed within a prestressed concrete reactor vessel (PCRV). Various carbon steel structural members serve as closures at penetrations in the vessel. A program of testing and evaluation is underway to determine the need for reference fracture toughness (K/sub IR/) and indexing procedures for these materials as described in Appendix G to Section III, ASME Code for light water reactor steels. The materials of interest are carbon steel forgings (SA508, Class 1) and plates (SA537, Classes 1 and 2) as well as weldments of these steels. The fracture toughness behavior is characterized with instrumented precracked Charpy V-votch specimens (PCVN) - slow-bend and dynamic - and compact specimens (10-mm and 25-mm thicknesses) using both linear elastic (ASTM E399) and elastic-plastic (equivalent Energy and J-Integral) analytical procedures. For the dynamic PCVN tests, force-time traces are analyzed according to the procedures of the Pressure Vessel Research Council (PVRC)/Metal Properties Council (MPC). Testing and analytical procedures are discussed and PCVN results are compared to those obtained with compact specimens

  17. ASTM international symposium on small specimen test techniques and their applications to pressure vessel annealing and plant life extension

    International Nuclear Information System (INIS)

    Garner, F.A.; Hamilton, M.L.; Heinisch, H.L.; Kumar, A.S.

    1992-01-01

    Miniature sheet-type tensile specimens are currently being used in a variety of radiation damage studies conducted in a number of different reactors. Although these specimens are very small, they have proven successful in addressing issues encountered in both thermal reactors and anticipated fusion reactors. This paper reviews the results of a number of recent studies that illustrate the range of applicability of these small specimens. When combined with other types of specimens and other types of measurements made prior to tensile testing, miniature tensile specimens have been found to serve as very useful tools for application to both fundamental studies and alloy screening studies

  18. Strength Prediction and Failure Modes of Concrete Specimens Subjected to the Split Test

    DEFF Research Database (Denmark)

    Hoang, Linh Cao; Andersen, M.E.; Hansen, N.T.

    2014-01-01

    This paper deals with modelling and test of concrete specimens subjected to the Brazilian split test. Based on the fictitious crack concept, a simple model for the crack propagation process in the splitting plane is developed. From the model, it is possible to determine the distribution of residual...... tensile strength as crack propagation take place. The residual tensile strength is thereafter used in a rigid plastic analysis of the splitting failure. Based on this combined approach, the ultimate load may either be governed by crack propagation or by a plastic failure, which then terminates the crack...

  19. Apparatus and method for fatigue testing of a material specimen in a high-pressure fluid environment

    Science.gov (United States)

    Wang, Jy-An; Feng, Zhili; Anovitz, Lawrence M; Liu, Kenneth C

    2013-06-04

    The invention provides fatigue testing of a material specimen while the specimen is disposed in a high pressure fluid environment. A specimen is placed between receivers in an end cap of a vessel and a piston that is moveable within the vessel. Pressurized fluid is provided to compression and tension chambers defined between the piston and the vessel. When the pressure in the compression chamber is greater than the pressure in the tension chamber, the specimen is subjected to a compression force. When the pressure in the tension chamber is greater than the pressure in the compression chamber, the specimen is subjected to a tension force. While the specimen is subjected to either force, it is also surrounded by the pressurized fluid in the tension chamber. In some examples, the specimen is surrounded by hydrogen.

  20. Testing Mechanisms for Philanthropic Behaviour

    NARCIS (Netherlands)

    Bekkers, R.H.F.P.; Wiepking, P.

    2011-01-01

    This special issue of the International Journal of Nonprofit and Voluntary Sector Marketing presents a collection of nine papers testing mechanisms that drive philanthropic behaviour. By testing one or more specific mechanisms that were derived from the philanthropic literature, the authors of the

  1. COMPARISON BETWEEN WOOD DRYING DEFECT SCORES: SPECIMEN TESTING X ANALYSIS OF KILN-DRIED BOARDS

    OpenAIRE

    Djeison Cesar Batista; Márcio Pereira da Rocha; Ricardo Jorge Klitzke

    2015-01-01

    It is important to develop drying technologies for Eucalyptus grandis lumber, which is one of the most planted species of this genus in Brazil and plays an important role as raw material for the wood industry. The general aim of this work was to assess the conventional kiln drying of juvenile wood of three clones of Eucalyptus grandis. The specific aims were to compare the behavior between: i) drying defects indicated by tests with wood specimens and conventional kiln-dried boards; and ii) ph...

  2. Asphalt Mixture Fatigue Testing : Influence of Test Type and Specimen Size

    NARCIS (Netherlands)

    Li, N.

    2013-01-01

    Fatigue characterization of an asphalt mixture is commonly estimated by laboratory fatigue tests. Based on the classical fatigue analysis, fatigue lives obtained from different test devices are not comparable even when they are performed at the same test conditions. It is believed that there are two

  3. Advanced Mechanical Testing of Sandwich Materials

    DEFF Research Database (Denmark)

    Hayman, Brian; Berggreen, Christian; Jenstrup, Claus

    2008-01-01

    An advanced digital optical system has been used to measure surface strains on sandwich face and core specimens tested in a project concerned with improved criteria for designing sandwich X-joints. The face sheet specimens were of glass reinforced polyester and were tested in tension. The core sp...

  4. Gamma irradiation test report of simulated grout specimens for gas generation/liquid advection

    International Nuclear Information System (INIS)

    Hinman, C.A.

    1994-01-01

    This report presents the results from an irradiation test performed on four specimens of grout that were fabricated from synthetic Double Shell Slurry Feed (DSSF) liquid waste. The objective was to investigate the radiolytic generation of gases and the potential for advective rejection of waste liquids from the grout matrix and to provide experimental information for the validation of the C-Cubed calculated model. It has been demonstrated that a number of gases can be formed within the grout due to radiolytic decomposition of various chemical components that make up the grout. This observation leads to the conjecture that the potential exists for the rejection of a portion of the 60 vol% free liquid from the grout matrix driven by pressurization by these gases. It was found that, for the specimen geometries used in this test series, and for peak radiation dose accumulation rates on the order of 4 to 60 times of the initial rate expected in the grout vaults (300 Rads/hr), no liquid rejection was observed from 2% to 35% of the target exposure expected in the grout vaults (1E+08 Rads). When the irradiation rate exceeded the projected grout vault dose rate by a factor of 200 a small amount of liquid rejection was observed from one of two specimens that had received 20% more than the goal exposure. Because of the differences in the magnitudes of the relative radiation field strengths between this study and an actual grout vault, it is concluded that the potential for liquid rejection by internal gas pressurization from presently configured grout waste forms is very low for the expected conditions

  5. Determination of the DBTT of Aluminide Coatings and its Influence on the Mechanical Behavior of Coated Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Dryepondt, Sebastien N [ORNL; Pint, Bruce A [ORNL

    2010-01-01

    The ductility of various coatings deposited by chemical vapor deposition, pack cementation and slurry processes on Fe- and Ni-based alloys was characterized by indentation at room temperature. A hot indentation apparatus has also been developed to more rapidly determine the ductile to brittle transition temperature of coated specimens. Creep testing has been conducted on bare and coated alloy 230 (NiCrW) specimens at 800 C with a significant decrease in creep life observed. Based on the observed failure of coated 230 specimens, the impact of coating ductility on substrate creep properties is discussed.

  6. The hardness test: a real mechanical test

    International Nuclear Information System (INIS)

    Rezakhanlou, R.

    1993-02-01

    During the service life, the mechanical properties of the PWR components change. It is necessary to determine precisely this evolution, but it is not always possible to draw a sample with the adequate size for the characterization. For this latter case we intend to calculate the stress-strain curve of a material from a hardness test results, because it is appropriate for testing on site and do not need any particular sample shape. This paper is the first bibliographical part of a larger study on the relation between the values measured during a hardness test (applied load, indentation diameter) and the mechanical properties of a solid obtained by a traction test. We have treated the problem within the general setting of two solids in contact. Thus, we expose general elastic, elasto-plastic and plastic models describing the indentation of a solid by a rigid indenter

  7. Mechanical/structural performance test method of a spacer grid

    International Nuclear Information System (INIS)

    Yoon, Kyung Ho

    2000-06-01

    The spacer grid is one of the main structural components in the fuel assembly, which supports the fuel rods, guides cooling water, and protects the system from an external impact load, such as earthquakes. In order to develop the spacer grid with the high mechanical performance, the mechanical and structural properties of the spacer grids must be extensively examined while designing it. In this report, the mechanical/structural test methods, i.e. the characteristic test of a spacer grid spring or dimple, static buckling test of a partial or full size spacer grid and dynamic impact test of them are described. The characteristic test of a spacer grid spring or dimple is accomplished with universal tensile test machine, a specimen is fixed with test fixture and then applied compressive load. The characteristic test data is saved at loading and unloading event. The static buckling test of a partial or full size spacer grid is executed with the same universal tensile testing machine, a specimen is fixed between cross-heads and then applied the compressive load. The buckling strength is decided the maximum strength at load vs. displacement curve. The dynamic impact test of a partial or full size spacer grid is performed with pendulum type impact machine and free fall shock test machine, a specimen is fixed with test fixture and then applied the impact load by impact hammer. Specially, the pendulum type impact test machine is also possible under the operating temperature because a furnace is separately attached with test machine

  8. Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Jacó Júlio de Souza; Cardoso, Domingos D' Oliveira; Gavazza, Sérgio; Oliveira, Cláudio Luiz de; Morales, Rudnei Karam, E-mail: jacojulio@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Amorim, Aneuri Souza de; Balthar, Mario Cesar Viegas; Oliveira, Luciano Santa Rita [Centro Tecnológico do Exercito (CETEx), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the {sup 18}F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens. (author)

  9. Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV

    International Nuclear Information System (INIS)

    Costa, Jacó Júlio de Souza; Cardoso, Domingos D'Oliveira; Gavazza, Sérgio; Oliveira, Cláudio Luiz de; Morales, Rudnei Karam; Amorim, Aneuri Souza de; Balthar, Mario Cesar Viegas; Oliveira, Luciano Santa Rita

    2017-01-01

    For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the 18 F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens. (author)

  10. Accelerated testing of space mechanisms

    Science.gov (United States)

    Murray, S. Frank; Heshmat, Hooshang

    1995-01-01

    This report contains a review of various existing life prediction techniques used for a wide range of space mechanisms. Life prediction techniques utilized in other non-space fields such as turbine engine design are also reviewed for applicability to many space mechanism issues. The development of new concepts on how various tribological processes are involved in the life of the complex mechanisms used for space applications are examined. A 'roadmap' for the complete implementation of a tribological prediction approach for complex mechanical systems including standard procedures for test planning, analytical models for life prediction and experimental verification of the life prediction and accelerated testing techniques are discussed. A plan is presented to demonstrate a method for predicting the life and/or performance of a selected space mechanism mechanical component.

  11. A microfluidic-enabled mechanical microcompressor for the immobilization of live single- and multi-cellular specimens.

    Science.gov (United States)

    Yan, Yingjun; Jiang, Liwei; Aufderheide, Karl J; Wright, Gus A; Terekhov, Alexander; Costa, Lino; Qin, Kevin; McCleery, W Tyler; Fellenstein, John J; Ustione, Alessandro; Robertson, J Brian; Johnson, Carl Hirschie; Piston, David W; Hutson, M Shane; Wikswo, John P; Hofmeister, William; Janetopoulos, Chris

    2014-02-01

    A microcompressor is a precision mechanical device that flattens and immobilizes living cells and small organisms for optical microscopy, allowing enhanced visualization of sub-cellular structures and organelles. We have developed an easily fabricated device, which can be equipped with microfluidics, permitting the addition of media or chemicals during observation. This device can be used on both upright and inverted microscopes. The apparatus permits micrometer precision flattening for nondestructive immobilization of specimens as small as a bacterium, while also accommodating larger specimens, such as Caenorhabditis elegans, for long-term observations. The compressor mount is removable and allows easy specimen addition and recovery for later observation. Several customized specimen beds can be incorporated into the base. To demonstrate the capabilities of the device, we have imaged numerous cellular events in several protozoan species, in yeast cells, and in Drosophila melanogaster embryos. We have been able to document previously unreported events, and also perform photobleaching experiments, in conjugating Tetrahymena thermophila.

  12. Quantification of Applied Stresses of C-Ring Specimens for Stress Corrosion Cracking Tests

    International Nuclear Information System (INIS)

    Kim, Woo Gon; Kim, Sun Jae; Rhee, Chang Kyu; Kuk, Il Hiun; Choi, Jong Ho

    1997-01-01

    For comparing their resistances for stress-corrosion cracking(SCC) in the K600-MA, K690-MA, and K600-TT tubes, C-ring specimens were fabricated with the various thermal-treatments to control the distributions of the precipitates like Cr-carbides. The bending stresses were analyzed to determine the amounts to make the stress quantitatively to all the C-ring samples, and then the stresses were calculated with the relation to the outer diameter(O.D) deflection(δ) of the C-rings. To measure accurately the bending strains of the C-ring specimens, the strain gauges were used and the compression test was also carried out. In the elastic region, the stresses in both the transverse and the circumferential directions were different with the locations of the strain gauges as attached at α= 30 .deg., 45 .deg., and 90 .deg. to the principal stress direction, but those in the longitudinal direction were independent of their attached locations. Calculated stresses from the strains obtained using the strain gauges were well agreed with the theoretical. In the plastic region over δ=1.0mm, the stresses for the TT tubes showed lower values of about 400MPa than those for the MA tubes. However, the stresses among the TT tubes showed almost the similar values in this region. Therefore, the states of the stresses applied to the C-ring specimens would be different with the material conditions, i.e, the chemical compositions, the thermal treatments such as MA and TT

  13. The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment

    Directory of Open Access Journals (Sweden)

    Byung Jae Lee

    2014-12-01

    Full Text Available In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise (Q∞ and the ternary blended cement mixture had the lowest reaction factor (r. Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.

  14. The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment.

    Science.gov (United States)

    Lee, Byung Jae; Bang, Jin Wook; Shin, Kyung Joon; Kim, Yun Yong

    2014-12-08

    In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise ( Q ∞ ) and the ternary blended cement mixture had the lowest reaction factor ( r ). Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q ∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.

  15. Development of the plant life management technology for RPV steels [ - Current status of surveillance test specimen reconstitution program -

    International Nuclear Information System (INIS)

    Kazunobu, Sakamoto; Eliichiro, Otsuka; Yoshiaki, Oka; Kosei, Taguchi; Michiyoshi, Yamamoto

    2001-01-01

    In order to develop the reconstitution technology to standardize surveillance test specimen reconstitution practices to deal with the extended service life of reactor pressure vessels, the Japan Power Engineering and Inspection Corporation (JAPEIC) has been carried out the project entrusted by the Ministry of International Trade and Industry (MITI). We focus on a correlation between the reduction of absorbed energy and the interaction of the heat affected zone (HAZ) and the plastic zone, to establish applicable reconstitution conditions for Charpy specimens. The relationship between the plastic zone width and the absorbed energy has been obtained by estimating the plastic zone width from the hardness distribution of the Charpy specimens. Impact tests of reconstituted specimens with 10 mm-length insert using the surface activated joining method were performed and the test results were compared to those obtained by the standard specimens. By comparing the length of insert material to the sum of HAZ width and plastic zone width, it is clear that the interaction causes the reduction of the absorbed energy. Hence, the applicable conditions of reconstituted Charpy specimens could be assessed by comparing the insert length to the sum of HAZ width and plastic zone width. Moreover the effects of the possible deviations from the standard shape and size specimens for the reconstituted specimens were studied. (authors)

  16. Investigation of the influence of different surface regularization methods for cylindrical concrete specimens in axial compression tests

    Directory of Open Access Journals (Sweden)

    R. MEDEIROS

    Full Text Available ABSTRACT This study was conducted with the aim of evaluating the influence of different methods for end surface preparation of compressive strength test specimens. Four different methods were compared: a mechanical wear method through grinding using a diamond wheel established by NBR 5738; a mechanical wear method using a diamond saw which is established by NM 77; an unbonded system using neoprene pads in metal retainer rings established by C1231 and a bonded capping method with sulfur mortar established by NBR 5738 and by NM 77. To develop this research, 4 concrete mixes were determined with different strength levels, 2 of group 1 and 2 of group 2 strength levels established by NBR 8953. Group 1 consists of classes C20 to C50, 5 in 5MPa, also known as normal strength concrete. Group 2 is comprised of class C55, C60 to C100, 10 in 10 MPa, also known as high strength concrete. Compression tests were carried out at 7 and 28 days for the 4 surface preparation methods. The results of this study indicate that the method established by NBR 5738 is the most effective among the 4 strengths considered, once it presents lower dispersion of values obtained from the tests, measured by the coefficient of variation and, in almost all cases, it demonstrates the highest mean of rupture test. The method described by NBR 5738 achieved the expected strength level in all tests.

  17. Advantages and disadvantages of technologies for HER2 testing in breast cancer specimens.

    Science.gov (United States)

    Furrer, Daniela; Sanschagrin, François; Jacob, Simon; Diorio, Caroline

    2015-11-01

    Human epidermal growth factor receptor 2 (HER2) plays a central role as a prognostic and predictive marker in breast cancer specimens. Reliable HER2 evaluation is central to determine the eligibility of patients with breast cancer to targeted anti-HER2 therapies such as trastuzumab and lapatinib. Presently, several methods exist for the determination of HER2 status at different levels (protein, RNA, and DNA level). In this review, we discuss the main advantages and disadvantages of the techniques developed so far for the evaluation of HER2 status in breast cancer specimens. Each technique has its own advantages and disadvantages. It is therefore not surprising that no consensus has been reached so far on which technique is the best for the determination of HER2 status. Currently, emphasis must be put on standardization of procedures, internal and external quality control assessment, and competency evaluation of already existing methods to ensure accurate, reliable, and clinically meaningful test results. Development of new robust and accurate diagnostic assays should also be encouraged. In addition, large clinical trials are warranted to identify the technique that most reliably predicts a positive response to anti-HER2 drugs. Copyright© by the American Society for Clinical Pathology.

  18. Biaxial mechanical tests in zircaloy-4

    International Nuclear Information System (INIS)

    Mintzer, S.R.; Bordoni, R.A.A.; Falcone, J.M.

    1980-01-01

    The texture of the zircaloy-4 tubes used as cladding in nuclear fuel elements determines anisotropy of the mechanical properties. As a consequence, the uniaxial tests to determine the mechanical behaviour of the tubes are incomplete. Furthermore, the cladding in use is subject to creep with a state of biaxial tensions. For this reason it is also important to determine the biaxial mechanical properties. The creep tests were performed by internal pressure for a state of axial to circumferential tensions of 0.5. Among the experimental procedures are described: preparation of the test specimens, pressurizing equipment, and the implementation of a device that permits a permanent register of the deformation. For the non-irradiated Atucha type zircaloy-4 sheaths, experimental curves of circumferential deformation versus time were obtained, in tests at constant pressure and for different values of temperature and pressure. An empirical function was determined to adjust the experimental values for the speed of the circumferential deformation in terms of the initial tension applied, temperature and deformation, and the change of the corresponding parameters in accordance to the range of the tensions. Also the activation energy for creep was determined. (M.E.L.) [es

  19. Action Mechanism of Iridoid Compounds on Guinea-pig Right Atrium Specimens

    OpenAIRE

    齊藤, 久美子; 酒井 淳一; 堀田 芳弘

    2016-01-01

     We examined the actions of iridoid compounds (aucubin (Auc), geniposidic acid (GA)) and a noniridoid compound (chlorogenic acid (CA)) contained in Eucommia leaves [1] [2], which show blood pressure-lowering effects, on the heart using right atrial specimens isolated from guinea pigs. These 3 compounds showed negative inotropic effects (NIE) and negative chronotropic effects (NCE) at a final concentration of 10 -5 or 10 -4 M in an experiment using right atrial specimens. Furthermore, pretreat...

  20. Demonstration of a chamber for strain mapping of steel specimens under mechanical load in a hydrogen environment by synchrotron radiation

    Science.gov (United States)

    Connolly, Matthew; Park, Jun-Sang; Bradley, Peter; Lauria, Damian; Slifka, Andrew; Drexler, Elizabeth

    2018-06-01

    We demonstrate a hydrogen gas chamber suitable for lattice strain measurements and capturing radiographs of a steel specimen under a mechanical load using high energy synchrotron x-rays. The chamber is suitable for static and cyclic mechanical loading. Experiments were conducted at the 1-ID-E end station of the Advanced Photon Source, Argonne National Laboratory. Diffraction patterns show a high signal-to-noise ratio suitable for lattice strain measurements for the specimen and with minimal scattering and overlap from the gas chamber manufactured from aluminum. In situ radiographs of a specimen in the hydrogen chamber show the ability to track a growing crack and to map the lattice strain around the crack with high spatial and strain resolution.

  1. Progress in Tissue Specimens Alternative for the Driver Genes Testing of Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Yan SUN

    2015-06-01

    Full Text Available Target treatment based on driver genes in advanced non-small cell lung cancer is very important currently. Tumor tissues is the gold standard for driver genes testing. However, most of patients could not get the gene information for lack of enough tissues. To explore the tissue specimens alternatives is a hot spot in clinical work. This report reviews the tissue specimen alternatives of driver gene testing in non-small cell lung cancer.

  2. Material Models to Study the Bauschinger Effect on an Aluminum Shear Test Specimen

    International Nuclear Information System (INIS)

    Cardoso, Rui P. R.; Gracio, Jose J.; Yoon, Jeong-Whan

    2007-01-01

    Sheet metal forming processes generally involve complex loadings and nonlinear material models. Combinations of drawing, re-drawing and/or reverse drawing operations commonly induce cyclic loads with non-proportional strain paths, leading to Bauschinger effects that can not be predicted by conventional isotropic hardening laws. In order to properly represent this effect, it is also required to accommodate an appropriate kinematic hardening model along with an anisotropic yield function. In this work, two different approaches will be used to predict the Bauschinger effect for an Aluminum shear test specimen: the rate dependent crystal plasticity model and a new combined isotropic/kinematic hardening model based on the two yield surfaces approach (loading and boundary yield surfaces), as recently proposed

  3. Lessons learned from nanoscale specimens tested by MEMS-based apparatus

    Science.gov (United States)

    Elhebeary, Mohamed; Saif, M. Taher A.

    2017-06-01

    The last two decades were marked by the innovative synthesis of nanomaterials and devices. The success of these devices hinges on the mechanical properties of nanomaterials and an understanding of their deformation and failure mechanisms. Many novel testing techniques have been developed to test materials at small scale. This paper reviews the state-of-the-art microelectromechanical systems (MEMS) apparatus developed to characterize materials at nanoscale, and the key insights gained on structure-property relations of materials through these characterizations. Finally, new applications of MEMS in testing living materials, such as tissues and cells, for disease diagnosis and prognosis are discussed.

  4. Lessons learned from nanoscale specimens tested by MEMS-based apparatus

    International Nuclear Information System (INIS)

    Elhebeary, Mohamed; Saif, M Taher A

    2017-01-01

    The last two decades were marked by the innovative synthesis of nanomaterials and devices. The success of these devices hinges on the mechanical properties of nanomaterials and an understanding of their deformation and failure mechanisms. Many novel testing techniques have been developed to test materials at small scale. This paper reviews the state-of-the-art microelectromechanical systems (MEMS) apparatus developed to characterize materials at nanoscale, and the key insights gained on structure-property relations of materials through these characterizations. Finally, new applications of MEMS in testing living materials, such as tissues and cells, for disease diagnosis and prognosis are discussed. (topical review)

  5. USFDA-GUIDELINE BASED VALIDATION OF TESTING METHOD FOR RIFAMPICIN IN INDONESIAN SERUM SPECIMEN

    Directory of Open Access Journals (Sweden)

    Tri Joko Raharjo

    2010-06-01

    Full Text Available Regarding a new regulation from Indonesia FDA (Badan POM-RI, all new non patent drugs should show bioequivalence with the originator drug prior to registration. Bioequivalence testing (BE-testing has to be performed to the people that represented of population to which the drug to be administrated. BE testing need a valid bio-analytical method for certain drug target and group of population. This research report specific validation of bio-analysis of Rifampicin in Indonesian serum specimen in order to be used for BE testing. The extraction was performed using acetonitrile while the chromatographic separation was accomplished on a RP 18 column (250 × 4.6 mm i.d., 5 µm, with a mobile phase composed of KH2PO4 10 mM-Acetonitrile (40:60, v/v and UV detection was set at 333 nm. The method shown specificity compared to blank serum specimen with retention time of rifampicin at 2.1 min. Lower limit of quantification (LLOQ was 0.06 µg/mL with dynamic range up to 20 µg/mL (R>0.990. Precision of the method was very good with coefficient of variance (CV 0.58; 7.40 and 5.56% for concentration at 0.06, 5, 15 µg/mL, respectively. Accuracies of the method were 3.22; 1.94; 1.90% for concentration 0.06, 5 and 15 µg/mL respectively. The average recoveries were 97.82, 95.50 and 97.31% for concentration of rifampicin 1, 5 and 5 µg/mL, respectively. The method was also shown reliable result on stability test on freezing-thawing, short-term and long-term stability as well as post preparation stability. Validation result shown that the method was ready to be used for Rifampicin BE testing with Indonesian subject.   Keywords: Rifampicin, Validation, USFDA-Guideline

  6. UKAEA mechanical test work in sodium

    International Nuclear Information System (INIS)

    Wood, D.S.

    1977-01-01

    The main aim of the UKAEA work is to perform mechanical tests in high quality sodium, and on the basis of relatively long term tests to establish whether factors need to be applied to the air data for the design and assessment of components which will have to operate in sodium for up to 30 years. Most of the tests will be performed in sodium containing 5-10 ppm O 2 and ∼ 1 ppm C with a flow rate over the specimen surface of 3m/sec. Some work is also planned to establish the effect of changes in oxygen level up to 30 ppm on the properties and carburization studies will also be performed. Thin work has been in progress on a limited scale for 2-3 years but is now increasing in magnitude to meet the programme requirements. The materials under test include Type 316 steel and 9% Cr steel with most emphasis being placed on the austenitic steel. From the very limited fatigue and stress rupture tests so far performed on Type 316 steel there is no evidence to suggest that high purity sodium may be detrimental. Longer term tests are necessary however to confirm this finding which is based on results from relatively short term tests. Tests are also necessary in less pure sodium

  7. Fracture assessment of HSST Plate 14 shallow-flaw cruciform bend specimens tested under biaxial loading conditions

    Energy Technology Data Exchange (ETDEWEB)

    Bass, B.R.; McAfee, W.J.; Williams, P.T.; Pennell, W.E.

    1998-06-01

    A technology to determine shallow-flaw fracture toughness of reactor pressure vessel (RPV) steels is being developed for application to the safety assessment of RPVs containing postulated shallow surface flaws. Matrices of cruciform beam tests were developed to investigate and quantify the effects of temperature, biaxial loading, and specimen size on fracture initiation toughness of two-dimensional (constant depth), shallow, surface flaws. The cruciform beam specimens were developed at Oak Ridge National Laboratory (ORNL) to introduce a far-field, out-of-plane biaxial stress component in the test section that approximates the nonlinear stresses resulting from pressurized-thermal-shock or pressure-temperature loading of an RPV. Tests were conducted under biaxial load ratios ranging from uniaxial to equibiaxial. These tests demonstrated that biaxial loading can have a pronounced effect on shallow-flaw fracture toughness in the lower transition temperature region for an RPV material. The cruciform fracture toughness data were used to evaluate fracture methodologies for predicting the observed effects of biaxial loading on shallow-flaw fracture toughness. Initial emphasis was placed on assessment of stress-based methodologies, namely, the J-Q formulation, the Dodds-Anderson toughness scaling model, and the Weibull approach. Applications of these methodologies based on the hydrostatic stress fracture criterion indicated an effect of loading-biaxiality on fracture toughness; the conventional maximum principal stress criterion indicated no effect. A three-parameter Weibull model based on the hydrostatic stress criterion is shown to correlate the experimentally observed biaxial effect on cleavage fracture toughness by providing a scaling mechanism between uniaxial and biaxial loading states.

  8. Study on Identification of Material Model Parameters from Compact Tension Test on Concrete Specimens

    Science.gov (United States)

    Hokes, Filip; Kral, Petr; Husek, Martin; Kala, Jiri

    2017-10-01

    Identification of a concrete material model parameters using optimization is based on a calculation of a difference between experimentally measured and numerically obtained data. Measure of the difference can be formulated via root mean squared error that is often used for determination of accuracy of a mathematical model in the field of meteorology or demography. The quality of the identified parameters is, however, determined not only by right choice of an objective function but also by the source experimental data. One of the possible way is to use load-displacement curves from three-point bending tests that were performed on concrete specimens. This option shows the significance of modulus of elasticity, tensile strength and specific fracture energy. Another possible option is to use experimental data from compact tension test. It is clear that the response in the second type of test is also dependent on the above mentioned material parameters. The question is whether the parameters identified within three-point bending test and within compact tension test will reach the same values. The presented article brings the numerical study of inverse identification of material model parameters from experimental data measured during compact tension tests. The article also presents utilization of the modified sensitivity analysis that calculates the sensitivity of the material model parameters for different parts of loading curve. The main goal of the article is to describe the process of inverse identification of parameters for plasticity-based material model of concrete and prepare data for future comparison with identified values of the material model parameters from different type of fracture tests.

  9. Characterization of test specimens produced in reduced size for X-ray microtomography (µ-CT tests

    Directory of Open Access Journals (Sweden)

    E. E. BERNARDES

    Full Text Available Abstract The need to use reduced sample sizes, in order to attain improved spatial resolution in (µ-CT tests applied in Portland cement composites, makes researchers perform the fractionation of materials to obtain samples with dimensions compatible with the capacity of the scanning equipment, which might cause alterations in the microstructure under analysis. Therefore, a test specimen (TS with dimensions compatible with the scanning capacity of a microtomography system that operates with an X-ray tube and voltage ranging from 20 to 100 kV was proposed. Axial compression strength tests were made and their total porosity was assessed by an apparent density and solid fraction density ratio, which were obtained by means of mercury and helium pycnometry and µ-CT technique, respectively. The adoption of that TS has shown to be viable for providing a sample with a higher level of representation.

  10. Design and use of nonstandard tensile specimens for irradiated materials testing

    International Nuclear Information System (INIS)

    Panayotou, N.F.

    1984-10-01

    Miniature, nonstandard, tensile-type specimens have been developed for use in radiation effects experiments at high energy neutron sources where the useful radiation volume is as small as a few cubic centimeters. The end result of our development is a sheet-type specimen, 12.7 mm long with a 5.1 mm long, 1.0 mm wide gage section, which is typically fabricated from 0.25 mm thick sheet stock by a punching technique. Despite this miniature geometry, it has been determined that the data obtained using these miniature specimens are in good agreement with data obtained using much larger specimens. This finding indicates that miniature tensile specimen data may by used for engineering design purposes. Furthermore, it is clear that miniature tensile specimen technology is applicable to fields other than the study of radiation effects. This paper describes the miniature specimen technology which was developed and compares the data obtained from these miniature specimens to data obtained from much larger specimens. 9 figures

  11. Analysis of stress intensity factors for a new mechanical corrosion specimen

    International Nuclear Information System (INIS)

    Rassineux, B.; Crouzet, D.; Le Hong, S.

    1996-03-01

    Electricite de France is conducting a research program to determine corrosion cracking rates in the steam generators Alloy 600 tubes of the primary system. The objective is to correlate the cracking rates with the specimen stress intensity factor K I . One of the samples selected for the purpose of this study is the longitudinal notched specimen TEL (TEL: ''Tubulaire a Entailles Longitudinales''). This paper presents the analysis of the stress intensity factor and its experimental validation. The stress intensity factor has been evaluated for different loads using 3D finite element calculations with the Hellen-Parks and G(θ) methods. Both crack initiation and propagation are considered. As an assessment of the method, the numerical simulations are in good agreement with the fatigue crack growth rates measured experimentally for TEL and compact tension (CT) specimens. (authors). 8 refs., 6 figs., 2 tabs

  12. Linear Array Ultrasonic Test Results from Alkali-Silica Reaction (ASR) Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Khazanovich, Dr. Lev [Univ. of Minnesota, Minneapolis, MN (United States); Salles, Lucio [Univ. of Minnesota, Minneapolis, MN (United States)

    2016-04-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations.This report presents results of the ultrasound evaluation of four concrete slabs with varying levels of ASR damage present. This included an investigation of the experimental results, as well as a supplemental simulation considering the effect of ASR damage by elasto-dynamic wave propagation using a finite integration technique method. It was found that the Hilbert Transform Indicator (HTI), developed for quantification of freeze/thaw damage in concrete structures, could also be successfully utilized for quantification of ASR damage. internal microstructure flaws, and reinforcement locations.

  13. Residual stress state in pipe cut ring specimens for fracture toughness testing

    Energy Technology Data Exchange (ETDEWEB)

    Damjanovic, Darko [J.J. Strossmayer Univ. of Osijek, Slavonski Brod (Croatia). Mechanical Engineering Faculty; Kozak, Drazan [Zagreb Univ. (Croatia). Dept. for Mechanical Design; Marsoner, Stefan [Materials Center, Leoben (Austria).; Gubeljak, Nenad [Maribor Univ. (Slovenia). Chair of Mechanics

    2017-07-01

    Thin-walled pipes are not suitable for measuring fracture toughness parameters of vital importance because longitudinal crack failure is the most common failure mode in pipes. This is due to the impossibility to manufacture standard specimens for measuring fracture toughness, such as SENB or CT specimens, from the thin wall of the pipe. Previous works noticed this problem, but until now, a good and convenient solution has not been found or developed. To overcome this problem, very good alternative solution was proposed, the so-called pipe ring notched bend specimen (PRNB) [1-5]. Until now, only the idealized geometry PRNB specimen is analyzed, i. e., a specimen which is not cut out from an actual pipe but produced from steel plate. Based on that, residual stresses are neglected along with the imperfections in geometry (elliptical and eccentricity). The aim of this research is to estimate the residual stress state(s) in real pipes used in the boiler industry produced by hot rolling technique. These types of pipes are delivered only in normalized condition, but not stress relieved. Therefore, there are residual stresses present due to the manufacturing technique, but also due to uneven cooling after the production process. Within this paper, residual stresses are estimated by three methods: the incremental hole drilling method (IHMD), X-ray diffraction (XRD) and the splitting method (SM). Knowing the residual stress state in the ring specimen, it is possible to assess their impact on fracture toughness measured on the corresponding PRNB specimen(s).

  14. Residual stress state in pipe cut ring specimens for fracture toughness testing

    International Nuclear Information System (INIS)

    Damjanovic, Darko; Kozak, Drazan; Marsoner, Stefan; Gubeljak, Nenad

    2017-01-01

    Thin-walled pipes are not suitable for measuring fracture toughness parameters of vital importance because longitudinal crack failure is the most common failure mode in pipes. This is due to the impossibility to manufacture standard specimens for measuring fracture toughness, such as SENB or CT specimens, from the thin wall of the pipe. Previous works noticed this problem, but until now, a good and convenient solution has not been found or developed. To overcome this problem, very good alternative solution was proposed, the so-called pipe ring notched bend specimen (PRNB) [1-5]. Until now, only the idealized geometry PRNB specimen is analyzed, i. e., a specimen which is not cut out from an actual pipe but produced from steel plate. Based on that, residual stresses are neglected along with the imperfections in geometry (elliptical and eccentricity). The aim of this research is to estimate the residual stress state(s) in real pipes used in the boiler industry produced by hot rolling technique. These types of pipes are delivered only in normalized condition, but not stress relieved. Therefore, there are residual stresses present due to the manufacturing technique, but also due to uneven cooling after the production process. Within this paper, residual stresses are estimated by three methods: the incremental hole drilling method (IHMD), X-ray diffraction (XRD) and the splitting method (SM). Knowing the residual stress state in the ring specimen, it is possible to assess their impact on fracture toughness measured on the corresponding PRNB specimen(s).

  15. Linear Array Ultrasonic Testing Of A Thick Concrete Specimens For Non-Destructive Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Khazanovich, Lev [Univ. of Minnesota, Minneapolis, MN (United States); Zammerachi, Mattia [Univ. of Minnesota, Minneapolis, MN (United States); Ezell, N. Dianne Bull [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-04-01

    The University of Minnesota and Oak Ridge National Laboratory are collaborating on the design and construction of a concrete specimen with sufficient reinforcement density and cross-sectional size to represent a light water reactor (LWR) containment wall with various defects. The preliminary analysis of the collected data using extended synthetic aperture focussin technique (SAFT) reconstruction indicated a great potential of the ultrasound array technology for locating relatively shallow distresses. However, the resolution and reliability of the analysis is inversely proportional to the defect depth and the amount of reinforcement between the measurement point and the defect location. The objective of this round of testing is to evaluate repeatability of the obtained reconstructions from measurements with different frequencies as well as to examine the effect of the duration of the sending ultrasound signal on the resulting reconstructions. Two series of testing are performed in this study. The objective of the first series is to evaluate repeatability of the measurements and resulting reconstructed images. The measurements use three center frequencies. Five measurements are performed at each location with and without lifting the device. The analysis of the collected data suggested that a linear array ultrasound system can produce reliably repeatable reconstructions using 50 kHz signals for relatively shallow depths (less than 0.5 m). However, for reconstructions at the greater depths the use of lower frequency and/or signal filtering to reduce the effect of signal noise may be required. The objective of the second series of testing is to obtain measurements with various impulse signal durations. The entire grid on the smooth surface is tested with four different various impulse signal durations. An analysis of the resulting extended SAFT reconstructions suggested that Kirchhoff-based migration leads to easier interpreting reconstructions when shorter duration

  16. Fatigue damage observed non-destructively in fibre composite coupon test specimens by X-ray CT

    DEFF Research Database (Denmark)

    Jespersen, Kristine Munk; Mikkelsen, Lars Pilgaard

    2016-01-01

    This study presents a method for monitoring the 3D fatigue damage progression on a micro-structural level in a glass fibre/polymer coupon test specimen by means of laboratory X-ray Computed Tomography (CT). A modified mount and holder made for the standard test samples to fit into the X-ray CT...... scanner along with a tension clamp solution is presented. Initially, the same location of the test specimen is inspected by ex-situ X-ray CT during the fatigue loading history, which shows the damage progression on a micro-structural level. The openings of individual uni-directional (UD) fibre fractures...

  17. Experimental validation of a new heterogeneous mechanical test design

    Science.gov (United States)

    Aquino, J.; Campos, A. Andrade; Souto, N.; Thuillier, S.

    2018-05-01

    Standard material parameters identification strategies generally use an extensive number of classical tests for collecting the required experimental data. However, a great effort has been made recently by the scientific and industrial communities to support this experimental database on heterogeneous tests. These tests can provide richer information on the material behavior allowing the identification of a more complete set of material parameters. This is a result of the recent development of full-field measurements techniques, like digital image correlation (DIC), that can capture the heterogeneous deformation fields on the specimen surface during the test. Recently, new specimen geometries were designed to enhance the richness of the strain field and capture supplementary strain states. The butterfly specimen is an example of these new geometries, designed through a numerical optimization procedure where an indicator capable of evaluating the heterogeneity and the richness of strain information. However, no experimental validation was yet performed. The aim of this work is to experimentally validate the heterogeneous butterfly mechanical test in the parameter identification framework. For this aim, DIC technique and a Finite Element Model Up-date inverse strategy are used together for the parameter identification of a DC04 steel, as well as the calculation of the indicator. The experimental tests are carried out in a universal testing machine with the ARAMIS measuring system to provide the strain states on the specimen surface. The identification strategy is accomplished with the data obtained from the experimental tests and the results are compared to a reference numerical solution.

  18. FRACTURE MECHANICS APPROACH TO ESTIMATE FATIGUE LIVES OF WELDED LAP-SHEAR SPECIMENS

    Energy Technology Data Exchange (ETDEWEB)

    Lam, P.; Michigan, J.

    2014-04-25

    A full range of stress intensity factor solutions for a kinked crack is developed as a function of weld width and the sheet thickness. When used with the associated main crack solutions (global stress intensity factors) in terms of the applied load and specimen geometry, the fatigue lives can be estimated for the laser-welded lap-shear specimens. The estimations are in good agreement with the experimental data. A classical solution for an infinitesimal kink is also employed in the approach. However, the life predictions tend to overestimate the actual fatigue lives. The traditional life estimations with the structural stress along with the experimental stress-fatigue life data (S-N curve) are also provided. In this case, the estimations only agree with the experimental data under higher load conditions.

  19. Plastic deformation and failure mechanisms in nano-scale notched metallic glass specimens under tensile loading

    Science.gov (United States)

    Dutta, Tanmay; Chauniyal, Ashish; Singh, I.; Narasimhan, R.; Thamburaja, P.; Ramamurty, U.

    2018-02-01

    In this work, numerical simulations using molecular dynamics and non-local plasticity based finite element analysis are carried out on tensile loading of nano-scale double edge notched metallic glass specimens. The effect of acuteness of notches as well as the metallic glass chemical composition or internal material length scale on the plastic deformation response of the specimens are studied. Both MD and FE simulations, in spite of the fundamental differences in their nature, indicate near-identical deformation features. Results show two distinct transitions in the notch tip deformation behavior as the acuity is increased, first from single shear band dominant plastic flow localization to ligament necking, and then to double shear banding in notches that are very sharp. Specimens with moderately blunt notches and composition showing wider shear bands or higher material length scale characterizing the interaction stress associated with flow defects display profuse plastic deformation and failure by ligament necking. These results are rationalized from the role of the interaction stress and development of the notch root plastic zones.

  20. 49 CFR 40.173 - Who is responsible for paying for the test of a split specimen?

    Science.gov (United States)

    2010-10-01

    ... is responsible for paying for the test of a split specimen? (a) As the employer, you are responsible... 49 Transportation 1 2010-10-01 2010-10-01 false Who is responsible for paying for the test of a.... (b) As the employer, you must not condition your compliance with these requirements on the employee's...

  1. Analysis of anisotropic damage in forged Al–Cu–Mg–Si alloy based on creep tests, micrographs of fractured specimen and digital image correlations

    Energy Technology Data Exchange (ETDEWEB)

    Gariboldi, Elisabetta, E-mail: elisabetta.gariboldi@polimi.it [Politecnico di Milano, Department of Mechanical Engineering, Via La Masa 34 20156 Milano (Italy); Naumenko, Konstantin, E-mail: konstantin.naumenko@ovgu.de [Otto-von-Guericke-University Magdeburg, Institute of Mechanics, D-39106 Magdeburg (Germany); Ozhoga-Maslovskaja, Oksana, E-mail: oksana.ozhogamaslovskaja@gmail.com [Politecnico di Milano, Department of Mechanical Engineering, Via La Masa 34 20156 Milano (Italy); Zappa, Emanuele, E-mail: emanuele.zappa@polimi.it [Politecnico di Milano, Department of Mechanical Engineering, Via La Masa 34 20156 Milano (Italy)

    2016-01-15

    The aim of this paper is to analyze anisotropic damage mechanisms in forged Al–Cu–Mg–Si alloy based on the results of creep tests. Smooth specimens are sampled in three forging directions. Creep strain vs. time curves as well as light optical microscope and scanning electron microscope observations illustrate basic features of damage growth. Flat notch specimens are sampled in different directions to analyze stress redistributions and damage in zones of stress concentration. The digital image correlation technique has been applied in situ in order to extract the strain values on the surface of the notched specimens. All observations demonstrate that the principal origins of anisotropic creep and damage are associated with elongated grains and second phase clustered particles located at grain boundaries. Longitudinal specimens possess nucleations of decohesion sites and growth of voids around second phase particles at grain boundaries. Damage evolution for radial and transverse specimens is due to the formation and growth of cracks in second phase particles orthogonal to the principal stress axis. Residual strains are confined to the notch root as well as to the flanges of advanced macrocrack, indicating the small scale yielding during the creep fracture process.

  2. Standard practice for verification of testing frame and specimen alignment under tensile and compressive axial force application

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2005-01-01

    1.1 Included in this practice are methods covering the determination of the amount of bending that occurs during the application of tensile and compressive forces to notched and unnotched test specimens in the elastic range and to plastic strains less than 0.002. These methods are particularly applicable to the force application rates normally used for tension testing, creep testing, and uniaxial fatigue testing.

  3. Standard practice for verification of testing frame and specimen alignment under tensile and compressive axial force application

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2014-01-01

    1.1 Included in this practice are methods covering the determination of the amount of bending that occurs during the application of tensile and compressive forces to notched and unnotched test specimens in the elastic range and to plastic strains less than 0.002. These methods are particularly applicable to the force application rates normally used for tension testing, creep testing, and uniaxial fatigue testing.

  4. Charpy impact test of oxidized and hydrogenated zircaloy using a thin strip specimen

    International Nuclear Information System (INIS)

    Otsuka, Teppei; Hashizume, Kenichi; Sugisaki, Masayasu

    2004-01-01

    The impact properties of an oxidized and a hydrogenated Zircaloy have been studied with an instrumented Charpy machine by using a strip Charpy V-notch specimen (1 mm thick by 4mm wide). Fracture processes such as crack initiation and propagation were examined using load-displacement curves obtained in this study. In the case of the hydrogenated specimen containing preferentially oriented hydrides, an appreciable decrease in the absorbed energy was observed in the crack propagation rather than in the crack initiation. From results of fractographs of the specimen, it was suggested that the reduction of the crack propagation energy of hydrogenated specimen could be attributed to the change of the stress state in the Zircaloy matrix, which was caused by the fracture of hydride in the inner part of specimen. In the case of the specimen oxidized at 973k for 60 min, on which an oxide layer (4 μm in thickness) and oxygen incursion layer (4μm) were formed, the surface layers affected the crack initiation process. The growing oxygen incursion layer, in particular, resulted in the constraint of plastic deformation of the Zircaloy matrix not only in the crack initiation but also in the crack propagation as its thickness increased. (author)

  5. Technique for the residual life assessment of high temperature components based on creep-rupture testing on welded miniature specimens

    Energy Technology Data Exchange (ETDEWEB)

    Garzillo, A.; Guardamagna, C.; Moscotti, L.; Ranzani, L. [Ente Nazionale per l`Energia Elettrica, Milan (Italy)

    1995-06-01

    Following the present trend in the development of advanced methodologies for residual life assessment of high temperature components operating in power plants, particularly in non destructive methods, a testing technique has been set up at ENEL-CRAM based on creep-rupture testa in an argon on welded miniature specimens. Five experimental systems for creep-rupture tests in an argon atmosphere have been set up which include high accuracy systems, vacuum chambers and exrwnsometer devices. With the aim of establishing and validating the suitability of the experimental methodology, creep-rupture and interrupted creep testing programmes have been performed on miniature specimens (2 mm diameter and 10 mm gauge lenght). On the basis of experience gathered by various European research laboratories, a miniature specimen construction procedure has been developed using a laser welding technique for joining threaded heads to sample material. Low alloy ferritic steels, such as virgin 2.25CrlMo, 0.5Cr 0.5Mo 0.25V, and IN 738 superalloy miniature specimens have been investigated and the results, compared with those from standard specimens, show a regular trend in deformation vs time. Additional efforts to provide guidelines for material sampling from each plant component will be required in order to reduce uncertainties in residual life prediction.

  6. Assessment of the stability of DNA in specimens collected under conditions for drug testing-A pilot study.

    Science.gov (United States)

    White, Robert M; Mitchell, John M; Hart, E Dale; Evans, Amy; Meaders, Meredith; Norsworthy, Sarah E; Hayes, Eugene D; Flegel, Ron; Maha, George C; Shaffer, Megan D; Hall, Erin M; Rogers, Kelley

    2018-02-01

    For forensic biological sample collections, the specimen donor is linked solidly to his or her specimen through a chain of custody (CoC) sometimes referenced as a chain of evidence. Rarely, a donor may deny that a urine or oral fluid (OF) specimen is his or her specimen even with a patent CoC. The goal of this pilot study was to determine the potential effects of short-term storage on the quality and quantity of DNA in both types of specimen under conditions that may be encountered with employment-related drug testing specimens. Fresh urine and freshly collected oral fluid all produced complete STR profiles. For the "pad" type OF collectors, acceptable DNA was extractable both from the buffer/preservative and the pad. Although fresh urine and OF produced complete STR profiles, partial profiles were obtained after storage for most samples. An exception was the DNA in the Quantisal OF collector, from which a complete profile was obtained for both freshly collected OF and stored OF. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Effects of crack front curvature on J–R curve testing using clamped SE(T) specimens of homogeneous materials

    International Nuclear Information System (INIS)

    Huang, Yifan; Zhou, Wenxing

    2015-01-01

    Three-dimensional (3D) finite element analyses (FEA) of clamped single-edge tension (SE(T)) specimens are performed to investigate the impact of the crack front curvature on the elastic compliance, compliance rotation correction factor and average J-integral evaluated over the crack front. Specimens with six average crack lengths (i.e. a_a_v_e/W = 0.2–0.7) and three thickness-to-width ratios (i.e. B/W = 0.5, 1 and 2) are analyzed. The curved crack front is assumed to be bowed symmetrically and characterized by a power-law expression with a wide range of curvatures. Several crack front straightness requirements for SE(B) and C(T) specimens specified in BS7448, ISO and ASTM E1820 standards are reviewed. Based on results of the numerical investigation, new crack front straightness criteria for the SE(T) specimen are proposed in the context of the nine-point measurement by using as a criterion that the errors in the estimated compliance and average J values should be no more than five percent. The proposed criteria depend on both a_a_v_e/W and B/W, and are more advantageous than those specified in the BS, ISO and ASTM standards in terms of controlling the differences in J and compliance between the specimens with curved and straight crack fronts. - Highlights: • Investigate the impacts of crack front curvature on the compliance, rotation correction factor and J for SE(T) specimens. • Validate the applicabilities of crack front straightness criteria specified in the seven test standards on SE(T) specimens. • Recommend new crack front straightness criteria for the SE(T) specimen.

  8. Effects of cavity surface temperature on mechanical properties of specimens with and without a weld line in rapid heat cycle molding

    International Nuclear Information System (INIS)

    Wang, Guilong; Zhao, Guoqun; Wang, Xiaoxin

    2013-01-01

    Highlights: ► Higher cavity surface temperature reduces tensile strength of non-weldline part. ► Higher cavity surface temperature increases weldline tensile strength for PS and PP. ► Higher cavity surface temperature reduces weldline tensile strength for ABS, ABS/PMMA, ABS/PMMA/nano-C a CO 3 and FRPP. ► Tensile strength is reduced more by the weldline than impact strength. ► FRPP has the lowest weld line factor than other plastics without reinforced fibers. - Abstract: Rapid heat cycle molding (RHCM) is a recently developed injection molding technology to enhance surface esthetic of the parts. By rapid heating and cooling of mold cavity surfaces in molding process, it can greatly alleviate or even eliminate the surface defects such as flow mark, weld line, glass fiber rich surface, silver mark, jetting mark, and swirl mark, and also improve gloss finish and dimensional accuracy without prolonging the molding cycle. Besides surface esthetic, mechanical property is also a very import issue for the molded plastic part. The aim of this study is focusing on the effects of the cavity surface temperature just before filling, T cs , in RHCM on the mechanical strength of the specimen with and without weld line. Six kinds of typical plastics including polystyrene (PS), polypropylene (PP), acrylonitrile butadiene styrene (ABS), acrylonitrile butadiene styrene/polymethylmethacrylate (ABS/PMMA), ABS/PMMA/nano-C a CO 3 and glass fiber reinforced polypropylene (FRPP) are used in experiments. The specimens with and without a weld line are produced with the different T cs on the developed electric-heating RHCM system. Tensile tests and notched Izod impact tests are conducted to characterize the mechanical strength of the specimens molded with different cavity surface temperatures. Simulations, differential scanning calorimetry (DSC), scanning electron microscope (SEM) and optical microscope are implemented to explain the impact mechanism of T cs on mechanical properties

  9. Illustration of the WPS benefit through BATMAN test series: Tests on large specimens under WPS loading configurations

    International Nuclear Information System (INIS)

    Yuritzinn, T.; Ferry, L.; Chapuliot, S.; Mongabure, P.; Moinereau, D.; Dahl, A.; Gilles, P.

    2008-01-01

    To study the effects of warm pre-stressing on the toughness of reactor pressure vessel steel, the 'Commissariat a l Energie Atomique', in collaboration with 'Electricite de France' and AREVA-NP, has made a study combining modeling and a series of experiments on large specimens submitted to a thermal shock or isothermal cooling. The tests were made on 18MND5 ferritic steel bars, containing a short or large fatigue pre-crack. The effect of 'warm pre-stressing' was confirmed, in the two cases of a fast thermal shock creating a gradient across the thickness of the bar and for gradual uniform cooling. In both cases, no propagation was observed during the thermal transient. Fracture occurred under low temperature conditions, at the end of the test when the tensile load was increased. The failure loads recorded were substantially higher than during pre-stressing. To illustrate the benefit of the WPS effect, numerical interpretations were performed using either global approach or local approach criteria. WPS effect and capability of models to predict it were then clearly shown. (authors)

  10. Study of residual stresses in CT test specimens welded by electron beam

    Science.gov (United States)

    Papushkin, I. V.; Kaisheva, D.; Bokuchava, G. D.; Angelov, V.; Petrov, P.

    2018-03-01

    The paper reports result of residual stress distribution studies in CT specimens reconstituted by electron beam welding (EBW). The main aim of the study is evaluation of the applicability of the welding technique for CT specimens’ reconstitution. Thus, the temperature distribution during electron beam welding of a CT specimen was calculated using Green’s functions and the residual stress distribution was determined experimentally using neutron diffraction. Time-of-flight neutron diffraction experiments were performed on a Fourier stress diffractometer at the IBR-2 fast pulsed reactor in FLNP JINR (Dubna, Russia). The neutron diffraction data estimates yielded a maximal stress level of ±180 MPa in the welded joint.

  11. 9 CFR 93.204 - Import permits for poultry and for poultry test specimens for diagnostic purposes; and...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Import permits for poultry and for poultry test specimens for diagnostic purposes; and reservation fees for space at quarantine facilities... SERVICE, DEPARTMENT OF AGRICULTURE EXPORTATION AND IMPORTATION OF ANIMALS (INCLUDING POULTRY) AND ANIMAL...

  12. 49 CFR Appendix C to Part 219 - Post-Accident Testing Specimen Collection

    Science.gov (United States)

    2010-10-01

    ... the transfer of the blood tubes on the second line of STEP 5 (the chain of custody block). E. Collect... (the chain of custody block). F. Seal the Individual Employee Kit a. The blood and urine specimens have... railroad representatives handling the box shall document chain of custody of the shipping box and shall...

  13. The problem of mechanical compatibility of natural building stones in restoration of monuments. Part I: Composite specimens

    Science.gov (United States)

    Kourkoulis, Stavros K.; Ninis, Nikolaos L.

    2011-12-01

    The mechanical compatibility of natural building stones used in the restoration of ancient monuments as substitutes of the authentic material is studied in this short two-paper series. Attention is focused on the porous oolitic limestone of Kenchreae used in the erection of the monuments at the Epidaurean Asklepieion. In Part I experimental results are presented concerning the mechanical properties and constants of both the authentic (ancient and freshly quarried) material and the various stones proposed so far as possible substitutes. It is concluded that only the Kenchreae stone satisfactorily simulates the behaviour of the material used by ancient Greeks. The other types of stones have a substantially different character and their incorporation in the restoration should be treated with caution. In an effort to quantify the influence of the substitute stone on the authentic one, a series of experiments were carried out using composite specimens made from equal parts of authentic and substitute material with various inclination angles of the adhesion plane with respect to the load. It was concluded that the mechanical properties of the composite specimen are strongly affected by this angle and the dependence is not monotonous. In addition, strong strain discontinuities are recorded in the vicinity of the adhesion plane, which are responsible for the initiation of cracking in either of the two materials. It was pointed out that in some cases the incompatibility causes violation of the basic restoration principle concerning the protection of the ancient material. In this context certain geometrical configurations of the boundaries of the specimens are examined in Part II as a possible means of modifying the mechanical behaviour of the substitute stones, in order to make them as compatible as possible with the authentic material.

  14. Irradiation of UO2 specimens with molten cores in a pressurized water loop. Test X-2-x

    International Nuclear Information System (INIS)

    Bain, A.S.

    1961-08-01

    Two Zircaloy-2 clad specimens containing stoichiometric UO 2 pellets were irradiated in a pressurized water loop for 379 hours at heat ratings sufficient to cause central melting of the UO 2 . There was no appearance of localized overheating or accelerated corrosion of the sheath, but the diametral increases were considerably larger than those observed in loop specimens irradiated at lower heat ratings. The length increases, however, were approximately the same as those measured for specimens at lower ratings. There was a clearly visible demarcation between UO 2 that had been molten and that which had not. The value of ∫ 500 o C Tm kdθ = 74 ± W/cm was essentially the same as that obtained from the short-duration tests in the Hydraulic Rabbit, indicating there is no marked decrease in thermal conductivity of the UO 2 fuel in irradiations up to 379 hours. (author)

  15. Safety and reliability of pressure components with special emphasis on the contribution of component and large specimen testing to structural integrity assessment methodology. Vol. 1 and 2

    International Nuclear Information System (INIS)

    1987-01-01

    The 51 papers of the 13. MPA-seminar contribute to structural integrity assessment methodology with special emphasis on the component and large specimen testing. 8 of the papers deal with fracture mechanics, 6 papers with dynamic loading, 13 papers with nondestructive testing, 2 papers with radiation embrittlement, 5 papers with pipe failure, 4 papers with components, 2 papers with thermal shock loading, 5 papers with the high temperature behaviour, 4 papers with the integrity of vessels and 3 papers with the integrity of welded joints. Especially also the fracture behaviour of steel material is verificated. All papers are separately indexed and analysed for the database. (DG) [de

  16. Development of specimen size and test rate effects on the J-integral upper transition behavior of A533B steel

    International Nuclear Information System (INIS)

    Joyce, James A.

    1988-01-01

    During the past three years a test method has been developed for dynamic testing of fracture mechanics specimens which is specifically designed for application to the upper transition temperature range. The method uses drop tower loading rates of 2.5 m/sec and obtains a J IC or a J-R curve using an analytical key curve approach verified by initial and final crack length measurements obtained from the fracture surface. A J-R curve is obtained from each specimen and contains crack growth corrections so that it is directly comparable with static results obtained in accordance with the ASTM E1152 J-R curve test method. The test procedure has been applied to A106 steel, A533B steel and US Navy HY80 and HY100 steels at temperatures from -200F to 150F. Standard 1T three point bend specimens were used for the A533B and the HY100 steel. Static test results have shown that the J at cleavage initiation (which is presently an unstandardized quantity) is specimen a/W independent throughout the ductile to brittle transition but of course demonstrates considerable statistical scatter in the vicinity of the ductile upper shelf. Dynamic J-R tests have shown an increase in J IC with test rate for most, but not for all, materials. Separation of J into elastic and plastic components shows that the elastic J component increases with test rate in a fashion consistent with the materials tensile sensitivity to test rate but the plastic J component decreases with test rate - an apparent visco-plastic phenomena. For A106 steel the plastic J decrease exceeds the elastic J increase and the upper shelf toughness falls - while the other materials have demonstrated a relatively larger increase in the elastic J component and a smaller decrease in the plastic J component giving an overall increase in upper shelf toughness. Separation of the J integral into elastic and plastic components has demonstrated that J EL is specimen scale and geometry dependent while J PL is relatively scale and geometry

  17. Ultrasonic NDE and mechanical testing of fiber placement composites

    Science.gov (United States)

    Liu, Zhanjie; Fei, Dong; Hsu, David K.; Dayal, Vinay; Hale, Richard D.

    2002-05-01

    A fiber placed composite, especially with fiber steering, has considerably more complex internal structure than a laminate laid up from unidirectional prepreg tapes. In this work, we performed ultrasonic imaging of ply interfaces of fiber placed composite laminates, with an eye toward developing a tool for evaluating their quality. Mechanical short-beam shear tests were also conducted on both nonsteered and steered specimens to examine their failure behavior and its relationship to the structural defects indicated by ultrasonic imaging.

  18. Beryllium irradiation embrittlement test programme. Material and specimen specification, manufacture and qualification

    International Nuclear Information System (INIS)

    Harries, D.R.; Dalle Donne, M.

    1996-06-01

    The report presents the specification, manufacture and qualification of the beryllium specimens to be irradiated in the BR2 reactor in Mol to investigate the effect of the neutron irradiation on the embrittlement as a function of temperature and beryllium oxide content. This work was been performed in the framework of the Nuclear Fusion Project of the Forschungszentrum Karlsruhe and is supported by the European Union within the European Fusion Technology Program. (orig.)

  19. Initial Mechanical Testing of Superalloy Lattice Block Structures Conducted

    Science.gov (United States)

    Krause, David L.; Whittenberger, J. Daniel

    2002-01-01

    The first mechanical tests of superalloy lattice block structures produced promising results for this exciting new lightweight material system. The testing was performed in-house at NASA Glenn Research Center's Structural Benchmark Test Facility, where small subelement-sized compression and beam specimens were loaded to observe elastic and plastic behavior, component strength levels, and fatigue resistance for hundreds of thousands of load cycles. Current lattice block construction produces a flat panel composed of thin ligaments arranged in a three-dimensional triangulated trusslike structure. Investment casting of lattice block panels has been developed and greatly expands opportunities for using this unique architecture in today's high-performance structures. In addition, advances made in NASA's Ultra-Efficient Engine Technology Program have extended the lattice block concept to superalloy materials. After a series of casting iterations, the nickel-based superalloy Inconel 718 (IN 718, Inco Alloys International, Inc., Huntington, WV) was successfully cast into lattice block panels; this combination offers light weight combined with high strength, high stiffness, and elevated-temperature durability. For tests to evaluate casting quality and configuration merit, small structural compression and bend test specimens were machined from the 5- by 12- by 0.5-in. panels. Linear elastic finite element analyses were completed for several specimen layouts to predict material stresses and deflections under proposed test conditions. The structural specimens were then subjected to room-temperature static and cyclic loads in Glenn's Life Prediction Branch's material test machine. Surprisingly, the test results exceeded analytical predictions: plastic strains greater than 5 percent were obtained, and fatigue lives did not depreciate relative to the base material. These assets were due to the formation of plastic hinges and the redundancies inherent in lattice block construction

  20. Dynamic Toughness Testing of Pre-Cracked Charpy V-Notch Specimens. Convention ELECTRABEL - SCK-CEN

    Energy Technology Data Exchange (ETDEWEB)

    Lucon, E

    1999-04-01

    This document describes the experimental and analytical procedures which have been adopted at the laboratories of the Belgian Nuclear Research Centre SCK-CEN for performing dynamic toughness tests on pre-cracked Charpy-V specimens. Such procedures were chosen on the basis of the existing literature on the subject, with several updates in the data analysis stages which reflect more recent developments in fracture toughness testing. Qualification tests have been carried out on PCCv specimens of JRQ steel, in order to assess the reliability of the results obtained; straightforward comparisons with reference data have been performed, as well as more advanced analyses using the Master Curve approach. Aspects related to machine compliance and dynamic tup calibration have also been addressed.

  1. Conversion of fracture toughness testing values from small scale three point bending test specimens to small scale yielding state (SSY) by elastic-plastic stress analysis

    International Nuclear Information System (INIS)

    Ikonen, K.

    1993-07-01

    The report describes the work performed for achieving readiness to calculate fracture toughness dependence on dimension effects and loading conditions in fracture test specimens and real structures. In the report two- and three-dimensional computer codes developed and calculational methods applied are described. One of the main goals is to converse fracture toughness from small scale three point bending test specimens to case of a depth crack in plane strain i.e. to small scale yielding state (SSY) by numerical elastic-plastic stress analysis. Thickness effect of a test specimens and effect of a crack depth are separately investigated. Tests of three point bending specimens with and without sidegrooves and curved crack front are numerically simulated and experimental and computed results are compared. J-integral is calculated along crack front and also from force-deflection dependence of the beam. For the analyses the computing system was thoroughly automatized. Measuring capacity of three point bending test specimens was tried to evaluate. (orig.) (7 refs., 54 figs.)

  2. Investigation of smooth specimen scc test procedures; variations in environment, specimen size, stressing frame, and stress state. [for high strength aluminum alloys

    Science.gov (United States)

    Lifka, B. W.; Sprowls, D. O.; Kelsey, R. A.

    1975-01-01

    The variables studied in the stress-corrosion cracking performance of high strength aluminum alloys were: (1) corrosiveness of the environment, (2) specimen size and stiffness of the stressing system, (3) interpretation of transgranular cracking, and (4) interaction of the state of stress and specimen orientation in a product with an anisotropic grain structure. It was shown that the probability of failure and time to fracture for a specimen loaded in direct tension are influenced by corrosion pattern, the stressing assembly stiffness, and the notch tensile strength of the alloy. Results demonstrate that the combination of a normal tension stress and a shear stress acting on the plane of maximum susceptibility in a product with a highly directional grain cause the greatest tendency for stress-corrosion cracking.

  3. Seismic functional qualification of active mechanical and electrical component based on shaking table testing

    International Nuclear Information System (INIS)

    Jurukovski, D.; Mamucevski, D.

    1996-01-01

    This report involves the description of the experimental seismic and vibration tests of electrical, mechanical and processing equipment that were carried out by using laboratory equipment with high performances. This equipment should generate programmable dynamic excitations, measure and analyze parameters defining dynamic behaviour of the structural and functional capabilities of the tested specimen. Development of testing methodology and criteria is described together with the method for processing the results. Application of the methodology and criteria to selected specimen is included

  4. Visualization test using piping group mock up specimen for evaluation of wastage phenomena in steam generator for FBR

    International Nuclear Information System (INIS)

    Kato, Keisuke; Yoshida, Atsuro; Arae, Kunihiko; Narabayashi, Tadashi; Ohshima, Hiroyuki; Kurihara, Akikazu

    2012-01-01

    There is a need for quantitative evaluation of wastage phenomena in steam generator for FBR. We focused attention on liquid droplet impingement erosion (LDIE) in wastage phenomena and performed basic study with piping group mock up specimen for quantitative evaluation of LDIE. First, we did visualization test of high pressure and high speed jet into the water. Test section mock up the crack of heat exchanger tube and neighboring heat exchanger tubes. We did the test under the following test conditions. Upstream pressure is 0.3MPa, vapor temperature is 300K, crack width is 0.1mm, and crack length is 40mm. (crack diameter is 0.2mm) Second, we did pressure and temperature measurement test in the same test conditions as before. We evaluated jet behavior at test section by those two tests. In addition, we did two phase flow analysis of the jet with TRAC code. (author)

  5. Contribution to the explanation of the spalling of small specimen without any mechanical restraint exposed to high temperature

    International Nuclear Information System (INIS)

    Morais, Marcus V.G. de; Pliya, Prosper; Noumowe, Albert; Beaucour, Anne-Lise; Ortola, Sophie

    2010-01-01

    The behaviour of concrete subjected to high temperature is studied. The aim of the study is to explain the spalling or bursting phenomenon observed during experimental studies in the laboratory. Mechanical computations are carried out with the finite element code CAST3M developed at the French Atomic Energy Agency (CEA). Heat gradient and water vapour pressure inside the concrete element are determined by using a thermo-hydrous model. Then, the mechanical stresses generated in the studied concrete element are calculated according to two behaviour assumptions: the linear isotropic elastic law and an elastoplastic model. Numerical simulations show that, during the heating cycles, tension stresses are developed in the central part and compression stresses at the surface of the cylindrical concrete element. The highest stresses appear when the surface temperature of the concrete element is about 300 o C. The tension stresses in the specimens then exceed the concrete tensile strength.

  6. Contribution to the explanation of the spalling of small specimen without any mechanical restraint exposed to high temperature

    Energy Technology Data Exchange (ETDEWEB)

    Morais, Marcus V.G. de, E-mail: mvmorais@unb.b [Cergy-Pontoise University - L2MGC, 5 mail Gay-Lussac Neuville sur Oise, 95031 Cergy-Pontoise Cedex (France); Pliya, Prosper [Cergy-Pontoise University - L2MGC, 5 mail Gay-Lussac Neuville sur Oise, 95031 Cergy-Pontoise Cedex (France); Noumowe, Albert, E-mail: Albert.Noumowe@u-cergy.f [Cergy-Pontoise University - L2MGC, 5 mail Gay-Lussac Neuville sur Oise, 95031 Cergy-Pontoise Cedex (France); Beaucour, Anne-Lise; Ortola, Sophie [Cergy-Pontoise University - L2MGC, 5 mail Gay-Lussac Neuville sur Oise, 95031 Cergy-Pontoise Cedex (France)

    2010-10-15

    The behaviour of concrete subjected to high temperature is studied. The aim of the study is to explain the spalling or bursting phenomenon observed during experimental studies in the laboratory. Mechanical computations are carried out with the finite element code CAST3M developed at the French Atomic Energy Agency (CEA). Heat gradient and water vapour pressure inside the concrete element are determined by using a thermo-hydrous model. Then, the mechanical stresses generated in the studied concrete element are calculated according to two behaviour assumptions: the linear isotropic elastic law and an elastoplastic model. Numerical simulations show that, during the heating cycles, tension stresses are developed in the central part and compression stresses at the surface of the cylindrical concrete element. The highest stresses appear when the surface temperature of the concrete element is about 300 {sup o}C. The tension stresses in the specimens then exceed the concrete tensile strength.

  7. Reverse-Transcriptase PCR Detection of Leptospira: Absence of Agreement with Single-Specimen Microscopic Agglutination Testing.

    Science.gov (United States)

    Waggoner, Jesse J; Balassiano, Ilana; Mohamed-Hadley, Alisha; Vital-Brazil, Juliana Magalhães; Sahoo, Malaya K; Pinsky, Benjamin A

    2015-01-01

    Reference diagnostic tests for leptospirosis include nucleic acid amplification tests, bacterial culture, and microscopic agglutination testing (MAT) of acute and convalescent serum. However, clinical laboratories often do not receive paired specimens. In the current study, we tested serum samples using a highly sensitive real-time nucleic acid amplification test for Leptospira and compared results to MAT performed on the same specimens. 478 serum samples from suspected leptospirosis cases in Rio de Janeiro were tested using a real-time RT-PCR for the diagnosis of leptospirosis, malaria and dengue (the Lepto-MD assay). The Lepto-MD assay detects all species of Leptospira (saprophytic, intermediate, and pathogenic), and in the current study, we demonstrate that this assay amplifies both Leptospira RNA and DNA. Dengue virus RNA was identified in 10 patients, and no cases of malaria were detected. A total of 65 samples (13.6%) were positive for Leptospira: 35 samples (7.3%) in the Lepto-MD assay, 33 samples (6.9%) by MAT, and 3 samples tested positive by both (kappa statistic 0.02). Poor agreement between methods was consistent regardless of the titer used to define positive MAT results or the day of disease at sample collection. Leptospira nucleic acids were detected in the Lepto-MD assay as late as day 22, and cycle threshold values did not differ based on the day of disease. When Lepto-MD assay results were added to the MAT results for all patients in 2008 (n=818), the number of detected leptospirosis cases increased by 30.4%, from 102 (12.5%) to 133 (16.3%). This study demonstrates a lack of agreement between nucleic acid detection of Leptospira and single-specimen MAT, which may result from the clearance of bacteremia coinciding with the appearance of agglutinating antibodies. A combined testing strategy for acute leptospirosis, including molecular and serologic testing, appears necessary to maximize case detection.

  8. Evaluation and Comparison of Multiple Test Methods, Including Real-time PCR, for Legionella Detection in Clinical Specimens

    Science.gov (United States)

    Peci, Adriana; Winter, Anne-Luise; Gubbay, Jonathan B.

    2016-01-01

    Legionella is a Gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture, and polymerase chain reaction (PCR) test methods and to determine if sputum is an acceptable alternative to the use of more invasive bronchoalveolar lavage (BAL). Data for this study included specimens tested for Legionella at Public Health Ontario Laboratories from 1st January, 2010 to 30th April, 2014, as part of routine clinical testing. We found sensitivity of urinary antigen test (UAT) compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV) 63.8%, and negative predictive value (NPV) 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7%, and NPV 98.1%. Out of 146 patients who had a Legionella-positive result by PCR, only 66 (45.2%) also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%); sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results regardless testing methods (Fisher Exact p-values = 1.0, for each test). In summary, all test methods have inherent weaknesses in identifying Legionella; therefore, more than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical from patients being tested for Legionella. PMID:27630979

  9. Method for efficient storage and transportation of sputum specimens for molecular testing of tuberculosis.

    Science.gov (United States)

    Guio, H; Okayama, H; Ashino, Y; Saitoh, H; Xiao, P; Miki, M; Yoshihara, N; Nakanowatari, S; Hattori, T

    2006-08-01

    The polymerase chain reaction (PCR) is a highly sensitive method for the detection of Mycobacterium tuberculosis and is available in most countries, though to a lesser extent in rural areas. To amplify M. tuberculosis DNA sequences of sputum spotted on FTA cards and compare them with the results of microscopic examination among culture-positive samples. A total of 102 sputum specimens of TB patients in treatment were spotted on FTA cards and stored at room temperature until DNA analysis. We assessed the IS6110 region of M. tuberculosis. The efficacy of the PCR assay for the direct detection of M. tuberculosis was evaluated and compared with the results of cultures (Middlebrook 7H9 broth) and smears of fresh sputum specimens. We were able to detect 10 fg/microl of mycobacterial DNA even after 6 months in storage. The PCR sensitivity and specificity using the FTA card system were 82% and 96%, while microscopic examination showed 41% and 95%, respectively. The FTA card system for the storage of bacterial DNA from sputum samples should be considered for the molecular diagnosis of tuberculosis. Samples can easily be obtained from geographically isolated populations and shipped by mail for accurate molecular diagnosis.

  10. Evaluation and comparison of multiple test methods, including real-time PCR, for Legionella detection in clinical specimens.

    Directory of Open Access Journals (Sweden)

    Adriana Peci

    2016-08-01

    Full Text Available Legionella is a gram-negative bacterium that can cause Pontiac fever, a mild upper respiratory infection and Legionnaire’s disease, a more severe illness. We aimed to compare the performance of urine antigen, culture and PCR test methods and to determine if sputum is an alternative to the use of more invasive bronchoalveolar lavage (BAL. Data for this study included specimens tested for Legionella at PHOL from January 1, 2010 to April 30, 2014, as part of routine clinical testing. We found sensitivity of UAT compared to culture to be 87%, specificity 94.7%, positive predictive value (PPV 63.8% and negative predictive value (NPV 98.5%. Sensitivity of UAT compared to PCR was 74.7%, specificity 98.3%, PPV 77.7% and NPV 98.1%. Of 146 patients who had a Legionella positive result by PCR, only 66(45.2% also had a positive result by culture. Sensitivity for culture was the same using either sputum or BAL (13.6%; sensitivity for PCR was 10.3% for sputum and 12.8% for BAL. Both sputum and BAL yield similar results despite testing methods (Fisher Exact p-values=1.0, for each test. In summary, all test methods have inherent weaknesses in identifying Legionella; thereforemore than one testing method should be used. Obtaining a single specimen type from patients with pneumonia limits the ability to diagnose Legionella, particularly when urine is the specimen type submitted. Given ease of collection, and similar sensitivity to BAL, clinicians are encouraged to submit sputum in addition to urine when BAL submission is not practical, from patients being tested for Legionella.

  11. Critical assessment of precracked specimen configuration and experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate

    Science.gov (United States)

    Domack, M. S.

    1985-01-01

    A research program was conducted to critically assess the effects of precracked specimen configuration, stress intensity solutions, compliance relationships and other experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate. Modified compact and double beam wedge-loaded specimens were tested and analyzed to determine the threshold stress intensity factor and stress corrosion crack growth rate. Stress intensity solutions and experimentally determined compliance relationships were developed and compared with other solutions available in the literature. Crack growth data suggests that more effective crack length measurement techniques are necessary to better characterize stress corrosion crack growth. Final load determined by specimen reloading and by compliance did not correlate well, and was considered a major source of interlaboratory variability. Test duration must be determined systematically, accounting for crack length measurement resolution, time for crack arrest, and experimental interferences. This work was conducted as part of a round robin program sponsored by ASTM committees G1.06 and E24.04 to develop a standard test method for stress corrosion testing using precracked specimens.

  12. Potential methods for determination of crack length of specimens in fracture mechanics

    International Nuclear Information System (INIS)

    Russenberger, M.E.

    1979-01-01

    For a wide and general use of neutron radiography in materials testing, transportable neutron sources are required which are strong enough for satisfactory pictures at a permissible radiation exposure time. These neutron sources are still lacking, and this shartage must be met by the development of better sources and imaging techniques which make better use of the given neutron flux- A simple method is presented that provides a better image quality due to a better absorption of neutrons, a larger amount of conversion radiation detected by the film, and reduced intrinsic unshapness. (orig.) [de

  13. Studies on sulfate attack: Mechanisms, test methods, and modeling

    Science.gov (United States)

    Santhanam, Manu

    The objective of this research study was to investigate various issues pertaining to the mechanism, testing methods, and modeling of sulfate attack in concrete. The study was divided into the following segments: (1) effect of gypsum formation on the expansion of mortars, (2) attack by the magnesium ion, (3) sulfate attack in the presence of chloride ions---differentiating seawater and groundwater attack, (4) use of admixtures to mitigate sulfate attack---entrained air, sodium citrate, silica fume, and metakaolin, (5) effects of temperature and concentration of the attack solution, (6) development of new test methods using concrete specimens, and (7) modeling of the sulfate attack phenomenon. Mortar specimens using portland cement (PC) and tricalcium silicate (C 3S), with or without mineral admixtures, were prepared and immersed in different sulfate solutions. In addition to this, portland cement concrete specimens were also prepared and subjected to complete and partial immersion in sulfate solutions. Physical measurements, chemical analyses and microstructural studies were performed periodically on the specimens. Gypsum formation was seen to cause expansion of the C3S mortar specimens. Statistical analyses of the data also indicated that the quantity of gypsum was the most significant factor controlling the expansion of mortar bars. The attack by magnesium ion was found to drive the reaction towards the formation of brucite. Decalcification of the C-S-H and its subsequent conversion to the non-cementitious M-S-H was identified as the mechanism of destruction in magnesium sulfate attack. Mineral admixtures were beneficial in combating sodium sulfate attack, while reducing the resistance to magnesium sulfate attack. Air entrainment did not change the measured physical properties, but reduced the visible distress of the mortars. Sodium citrate caused a substantial reduction in the rate of damage of the mortars due to its retarding effect. Temperature and

  14. Predicting crack instability behavior of burst tests from small specimens for irradiated Zr-2.5Nb pressure tubes

    International Nuclear Information System (INIS)

    Davies, P.H.

    1997-01-01

    A scaling approach, based on the deformation J-integral at maximum load obtained from small specimens, is proposed for predicting the crack instability behavior of burst tests on irradiated Zr-2.5Nb pressure tubes. An assessment of this approach is carried out by comparison with other toughness criteria such as the modified J-integral and the plastic work dissipation rate approach. The largest discrepancy between the different parameters occurs for materials of intermediate toughness which exhibit the most stable crack growth and tunnelling up to maximum load. A study of one material of intermediate toughness suggests crack-front tunnelling has a significant influence on the results obtained from the 17-mm-wide specimens. It is shown that for a tube of intermediate toughness the different approaches can significantly underpredict the extent of stable crack growth before instability in a burst test even after correcting for tunnelling. The usefulness of a scaling approach in reducing the discrepancy between the small- and large-scale specimen results for this material is demonstrated

  15. Charpy impact test results on five materials and NIST verification specimens using instrumented 2-mm and 8-mm strikers

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Sokolov, M.A.

    1995-01-01

    The Heavy-Section Steel Irradiation Program at Oak Ridge National Laboratory is involved in two cooperative projects, with international participants, both of which involve Charpy V-notch impact tests with instrumented strikers of 2mm and 8mm radii. Two heats of A 533 grade B class I pressure vessel steel and a low upper-shelf (LUS) submerged-arc (SA) weld were tested on the same Charpy machine, while one heat of a Russian Cr-Mo-V forging steel and a high upper-shelf (HUS) SA weld were tested on two different machines. The number of replicate tests at any one temperature ranged from 2 to 46 specimens. Prior to testing with each striker, verification specimens at the low, high, and super high energy levels from the National Institute of Standards and Technology (NIST) were tested. In the two series of verification tests, the tests with the 2mm striker met the requirements at the low and high energy levels but not at the super high energy. For one plate, the 2mm striker showed somewhat higher average absorbed energies than those for the 8-mm striker at all three test temperatures. For the second plate and the LUS weld, however, the 2mm striker showed somewhat lower energies at both test temperatures. For the Russian forging steel and the HUS weld, tests were conducted over a range of temperatures with tests at one laboratory using the 8mm striker and tests at a second laboratory using the 2mm striker. Lateral expansion was measured for all specimens and the results are compared with the absorbed energy results. The overall results showed generally good agreement (within one standard deviation) in energy measurements by the two strikers. Load-time traces from the instrumented strikers were also compared and used to estimate shear fracture percentage. Four different formulas from the European Structural Integrity Society draft standard for instrumented Charpy test are compared and a new formula is proposed for estimation of percent shear from the force-time trace

  16. New test structures and techniques for measurement of mechanical properties of MEMS materials

    Science.gov (United States)

    Sharpe, William N., Jr.; Yuan, Bin; Vaidyanathan, Ranji; Edwards, Richard L.

    1996-09-01

    This paper presents techniques and procedures for addressing the three major problems of mechanical testing of the thin films used in surface micromachined microelectromechanical systems--specimen handling, friction, and strain measurement. The polysilicon tensile specimens are fabricated with two supporting side strips on silicon wafers at the Microelectronic Center of North Carolina. The tensile specimen is released by etching away the wafer, and the two support strips are cut after the specimen is glued in the test machine. Friction is reduced by a linear air bearing in the load train, and strain is measured with a noncontacting technique based on laser interferometry between two gold lines on the tensile specimen. The Young's modulus of polysilicon is 170 +/- 7 GPa and the strength is 1.21 +/- 0.16 GPa from a series of 29 tests. preliminary measurements have been made of Poisson's ratio and the fatigue behavior, and an attempt is underway to measure the fracture toughness.

  17. Methodology for Mechanical Property Testing on Fuel Cladding Using an Expanded Plug Wedge Test

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [ORNL; Jiang, Hao [ORNL

    2013-08-01

    To determine the tensile properties of irradiated fuel cladding in a hot cell, a simple test was developed at ORNL and is described fully in US Patent Application 20060070455, Expanded plug method for developing circumferential mechanical properties of tubular materials. This method is designed for testing fuel rod cladding ductility in a hot cell utilizing an expandable plug to stretch a small ring of irradiated cladding material. The specimen strain is determined using the measured diametrical expansion of the ring. This method removes many complexities associated with specimen preparation and testing. The advantages are the simplicity of measuring the test component assembly in the hot cell and the direct measurement of specimen strain. It was also found that cladding strength could be determined from the test results. The basic approach of this test method is to apply an axial compressive load to a cylindrical plug of polyurethane (or other materials) fitted inside a short ring of the test material to achieve radial expansion of the specimen. The diameter increase of the specimen is used to calculate the circumferential strain accrued during the test. The other two basic measurements are total applied load and amount of plug compression (extension). A simple procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves. However, several deficiencies exist in this expanded-plug loading ring test, which will impact accuracy of test results and introduce potential shear failure of the specimen due to inherited large axial compressive stress from the expansion plug test. First of all, the highly non-uniform stress and strain distribution resulted in the gage section of the clad. To ensure reliable testing and test repeatability, the potential for highly non-uniform stress distribution or displacement/strain deformation has to be eliminated at the gage section of the specimen. Second, significant

  18. 46 CFR 57.04-1 - Test specimen requirements and definition of ranges (modifies QW 202, QW 210, QW 451, and QB 202).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Test specimen requirements and definition of ranges... HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING WELDING AND BRAZING Procedure Qualification Range § 57.04-1 Test specimen requirements and definition of ranges (modifies QW 202, QW 210, QW 451, and QB 202...

  19. Three-axial strain controlled testing applied to bone specimens from the proximal tibial epiphysis

    DEFF Research Database (Denmark)

    Linde, F.; Pongsoipetch, B.; Frich, Lars Henrik

    1990-01-01

    Reproducibility of the determination of Young's modulus and energy absorption along the three axes of trabecular bone cubes was analysed by non-destructive compression to 0.5% strain using different testing protocols. These protocols included testing with and without pre-conditioning to a viscoel......Reproducibility of the determination of Young's modulus and energy absorption along the three axes of trabecular bone cubes was analysed by non-destructive compression to 0.5% strain using different testing protocols. These protocols included testing with and without pre...

  20. Evaluation of constraint methodologies applied to a shallow-flaw cruciform bend specimen tested under biaxial loading conditions

    International Nuclear Information System (INIS)

    Bass, B.R.; McAfee, W.J.; Williams, P.T.; Pennell, W.E.

    1998-01-01

    A technology to determine shallow-flaw fracture toughness of reactor pressure vessel (RPV) steels is being developed for application to the safety assessment of RPVs containing postulated shallow surface flaws. Matrices of cruciform beam tests were developed to investigate and quantify the effects of temperature, biaxial loading, and specimen size on fracture initiation toughness of two-dimensional (constant depth), shallow surface flaws. The cruciform beam specimens were developed at Oak Ridge National Laboratory (ORNL) to introduce a prototypic, far-field. out-of-plane biaxial stress component in the test section that approximates the nonlinear stresses resulting from pressurized-thermal-shock or pressure-temperature loading of an RPV. Tests were conducted under biaxial load ratios ranging from uniaxial to equibiaxial. These tests demonstrated that biaxial loading can have a pronounced effect on shallow-flaw fracture toughness in the lower transition temperature region for RPV materials. The cruciform fracture toughness data were used to evaluate fracture methodologies for predicting the observed effects of biaxial loading on shallow-flaw fracture toughness. Initial emphasis was placed on assessment of stress-based methodologies. namely, the J-Q formulation, the Dodds-Anderson toughness scaling model, and the Weibull approach. Applications of these methodologies based on the hydrostatic stress fracture criterion indicated an effect of loading-biaxiality on fracture toughness, the conventional maximum principal stress criterion indicated no effect

  1. An Evaluation of the Cobas4800 HPV Test on Cervico-Vaginal Specimens in Liquid versus Solid Transport Media.

    Directory of Open Access Journals (Sweden)

    Hongxue Luo

    Full Text Available Determine the ability of the Cobas 4800 assay to detect high-risk human papillomavirus (HrHPV and high-grade cervical lesions when using cervico-vaginal samples applied to liquid medium and solid media cards compared to a direct cervical sample.Two cervico-vaginal specimens (pseudo self-collected were obtained from 319 women. One was applied to an iFTA Card (FTA then the brush placed in liquid-based medium (LSELF; the other was applied to a new solid media: POI card (POI. The clinical performance of Cobas4800 assay using the three aforementioned specimens was compared to direct collected endocervical specimens in liquid media (LDOC.The overall agreements of HrHPV detection were 84.2% (LSELF vs. LDOC, 81.0% (FTA vs. LDOC, and 82.3% (POI vs. LDOC. LSELF, FTA and POI identified 98.0%, 79.6%, and 97.5% positive cases of LDOC. Sensitivity to identify CIN2+ were 98.4% (LSELF, 73.8% (FTA, 95.1% (POI, and 93.4% (LDOC respectively. FTA had 78.1% and 90.4% agreement with the LSELF samples for all HrHPV and HPV16/18 detection respectively, while POI had 91.6% for both.Cobas4800 HPV test combined with cervico-vaginal specimens applied to both liquid media and POI solid card are accurate to detect HrHPV infection and high-grade cervical lesions as compared with direct endocervical samples in liquid media.

  2. An Evaluation of the Cobas4800 HPV Test on Cervico-Vaginal Specimens in Liquid versus Solid Transport Media.

    Science.gov (United States)

    Luo, Hongxue; Du, Hui; Maurer, Kathryn; Belinson, Jerome L; Wang, Guixiang; Liu, Zhihong; Zhang, Lijie; Zhou, Yanqiu; Wang, Chun; Tang, Jinlong; Qu, Xinfeng; Wu, Ruifang

    2016-01-01

    Determine the ability of the Cobas 4800 assay to detect high-risk human papillomavirus (HrHPV) and high-grade cervical lesions when using cervico-vaginal samples applied to liquid medium and solid media cards compared to a direct cervical sample. Two cervico-vaginal specimens (pseudo self-collected) were obtained from 319 women. One was applied to an iFTA Card (FTA) then the brush placed in liquid-based medium (LSELF); the other was applied to a new solid media: POI card (POI). The clinical performance of Cobas4800 assay using the three aforementioned specimens was compared to direct collected endocervical specimens in liquid media (LDOC). The overall agreements of HrHPV detection were 84.2% (LSELF vs. LDOC), 81.0% (FTA vs. LDOC), and 82.3% (POI vs. LDOC). LSELF, FTA and POI identified 98.0%, 79.6%, and 97.5% positive cases of LDOC. Sensitivity to identify CIN2+ were 98.4% (LSELF), 73.8% (FTA), 95.1% (POI), and 93.4% (LDOC) respectively. FTA had 78.1% and 90.4% agreement with the LSELF samples for all HrHPV and HPV16/18 detection respectively, while POI had 91.6% for both. Cobas4800 HPV test combined with cervico-vaginal specimens applied to both liquid media and POI solid card are accurate to detect HrHPV infection and high-grade cervical lesions as compared with direct endocervical samples in liquid media.

  3. Analysis of radioactive corrosion test specimens by means of ICP-MS. Comparison with earlier methods

    International Nuclear Information System (INIS)

    Forsyth, Roy

    1997-07-01

    In June 1992, an ICP-MS instrument (Inductively Coupled Plasma-Mass Spectrometry) was commissioned for use with radioactive sample solutions at Studsvik Nuclear's Hot Cell Laboratory. For conventional environmental samples the instrument permits the simultaneous analysis of many trace elements, but the software used in evaluation of the mass spectra is based on a library of isotopic compositions relevant only for elements in the lithosphere. Fission products and actinides, however, have isotopic compositions which are significantly different from the natural elements, and which also vary with the burnup of the nuclear fuel specimen. Consequently, a spread-sheet had to be developed which could evaluate the mass spectra with these isotopic compositions. Following these preparations, a large number of samples (about 200) from SKB's experimental programme for the study of spent fuel corrosion have been analyzed by the ICP-MS technique. Many of these samples were archive solutions of samples which had been taken earlier in the programme. This report presents a comparison of the analytical results for uranium, plutonium, cesium, strontium and technetium by both the ICP-MS technique, and the previously used analytical methods. For three products, a satisfactory agreement between the results from the various methods was obtained, but for uranium and plutonium the ICP-MS method gave results which were 10-20% higher than the conventional methods. The comparison programme has also shown, not unexpectedly, that significant losses of plutonium from solution had occurred, by precipitation and/or absorption, in the archive solutions during storage. It can be expected that such losses also occur for the other actinides, and consequently, all the analytical results for actinides in older archive solutions must be treated with great caution. 9 refs

  4. Horizontal loading test by whole model specimen simulating inner concrete structure of PWR type nuclear power plant

    International Nuclear Information System (INIS)

    Furuya, Noriyuki; Sekine, Masataka; Kimura, Kozo; Yamaguchi, Yoshihiro; Yamaguchi, Tsuneo; Takeda, Toshikazu

    1985-01-01

    The Nuclear Power Engineering Test Center has performed a horizontal loading test by a whole model specimen simulating the inner concrete structure of a PWR type nuclear power plant in order to investigate restoring force characteristics of reactor buildings. This report describes the results of examination of applicability to the test results of analysis methods based on elastic theory. The analysis results of elastic stiffness, concrete cracking load, rebar yielding loads and ultimate strength were compared with the test results. According to this examination, it is recognized that even these analysis methods based on elastic theory are comparatively effective for analysis of an inner concrete structure of fairly complex configuration, although there are limits of the scope of applicability. (author)

  5. Shaking table testing of mechanical components

    International Nuclear Information System (INIS)

    Jurukovski, D.; Taskov, Lj.; Mamucevski, D.; Petrovski, D.

    1995-01-01

    Presented is the experience of the Institute of Earthquake Engineering and Engineering Seismology, Skopje, Republic of Macedonia in seismic qualification of mechanical components by shaking table testing. Technical data and characteristics for the three shaking tables available at the Institute are given. Also, for characteristic mechanical components tested at the Institute laboratories, basic data such as producer, testing investor, description of the component, testing regulation, testing equipment and final user of the results. (author)

  6. Formulation of a new model of dynamic cracking in PLEXUS. First applications to a laboratory test specimen

    International Nuclear Information System (INIS)

    Jamet, P.

    1986-07-01

    The problem of dynamic rupture is important for nuclear power plant safety analysis, more particularly in case of cold shock in a PWR vessel. Preliminary studies showed that PLEXUS is a numerical frame well adapted to the analysis of the problem. The aim of this report is to present a new model implemented in PLEXUS, for a better simulation of splitting. A first trial taking into account the variation of the dynamic toughness versus crack propagation rate has been done (samples of steel AISI 4340). The model has been applied to the dynamic cracking of a test specimen. The influence of wave reflections at the structure limits has been clearly pointed out [fr

  7. Standard Test Method for Normal Spectral Emittance at Elevated Temperatures of Nonconducting Specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1971-01-01

    1.1 This test method describes an accurate technique for measuring the normal spectral emittance of electrically nonconducting materials in the temperature range from 1000 to 1800 K, and at wavelengths from 1 to 35 μm. It is particularly suitable for measuring the normal spectral emittance of materials such as ceramic oxides, which have relatively low thermal conductivity and are translucent to appreciable depths (several millimetres) below the surface, but which become essentially opaque at thicknesses of 10 mm or less. 1.2 This test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is particularly suitable for research laboratories, where the highest precision and accuracy are desired, and is not recommended for routine production or acceptance testing. Because of its high accuracy, this test method may be used as a reference method to be applied to production and acceptance testing in case of dispute. 1.3 This test metho...

  8. Shear compression testing of glass-fibre steel specimens after 4K reactor irradiation: Present status and facility upgrade

    International Nuclear Information System (INIS)

    Gerstenberg, H.; Kraehling, E.; Katheder, H.

    1997-01-01

    The shear strengths of various fibre reinforced resins being promising candidate insulators for superconducting coils to be used tinder a strong radiation load, e.g. in future fusion reactors were investigated prior and subsequent to reactor in-core irradiation at liquid helium temperature. A large number of sandwich-like (steel-bonded insulation-steel) specimens representing a widespread variety of materials and preparation techniques was exposed to irradiation doses of up to 5 x 10 7 Gy in form of fast neutrons and γ-radiation. In a systematic study several experimental parameters including irradiation dose, postirradiation storage temperature and measuring temperature were varied before the determination of the ultimate shear strength. The results obtained from the different tested materials are compared. In addition an upgrade of the in-situ test rig installed at the Munich research reactor is presented, which allows combined shear/compression loading of low temperature irradiated specimens and provides a doubling of the testing rate

  9. Performance of ARCHITECT HCV core antigen test with specimens from US plasma donors and injecting drug users.

    Science.gov (United States)

    Mixson-Hayden, Tonya; Dawson, George J; Teshale, Eyasu; Le, Thao; Cheng, Kevin; Drobeniuc, Jan; Ward, John; Kamili, Saleem

    2015-05-01

    Hepatitis C virus (HCV) core antigen is a serological marker of current HCV infection. The aim of this study was mainly to evaluate the performance characteristics of the ARCHITECT HCV core antigen assay with specimens from US plasma donors and injecting drug users. A total of 551 serum and plasma samples with known anti-HCV and HCV RNA status were tested for HCV core antigen using the Abbott ARCHITECT HCV core antigen test. HCV core antigen was detectable in 100% of US plasma donor samples collected during the pre-seroconversion phase of infection (anti-HCV negative/HCV RNA positive). Overall sensitivity of the HCV core antigen assay was 88.9-94.3% in samples collected after seroconversion. The correlation between HCV core antigen and HCV RNA titers was 0.959. HCV core antigen testing may be reliably used to identify current HCV infection. Published by Elsevier B.V.

  10. Fracture Characterization of PVC Foam Core Sandwich Specimen Using the DCB-UBM Test Method

    DEFF Research Database (Denmark)

    Saseendran, Vishnu; Berggreen, Christian; Carlsson, Leif A.

    coupled with experimental validation is paramount to determine the fracture resistance of the face/core interface. In this paper, the test-rig exploiting the double cantilever beam with uneven bending moments (DCB-UBM) concept is used to determine the fracture toughness of PVC foam core sandwich......Face/core debond failure in sandwich composites is a critical failure mode. Lack of cohesion between face and core will lead to loss of structural integrity. The estimation of interface fracture toughness especially at the face/core interface is extremely challenging, provided the dissimilarity...... composites. The DCB-UBM test enables fracture testing over a large range of mode-mixities as expressed by a phase angle (ψ) which is a measure of the amount of shear loading at the crack tip. A desired phase angle may be achieved by changing the moment-ratio (MR = Md/Ms)....

  11. Accelerated life tests of specimen heat pipe from Communication Technology Satellite (CTS) project

    Science.gov (United States)

    Tower, L. K.; Kaufman, W. B.

    1977-01-01

    A gas-loaded variable conductance heat pipe of stainless steel with methanol working fluid identical to one now on the CTS satellite was life tested in the laboratory at accelerated conditions for 14 200 hours, equivalent to about 70 000 hours at flight conditions. The noncondensible gas inventory increased about 20 percent over the original charge. The observed gas increase is estimated to increase operating temperature by about 2.2 C, insufficient to harm the electronic gear cooled by the heat pipes in the satellite. Tests of maximum heat input against evaporator elevation agree well with the manufacturer's predictions.

  12. Laparoscopic specimen retrieval bags.

    Science.gov (United States)

    Smorgick, Noam

    2014-10-01

    Specimen retrieval bags have long been used in laparoscopic gynecologic surgery for contained removal of adnexal cysts and masses. More recently, the concerns regarding spread of malignant cells during mechanical morcellation of myoma have led to an additional use of specimen retrieval bags for contained "in-bag" morcellation. This review will discuss the indications for use retrieval bags in gynecologic endoscopy, and describe the different specimen bags available to date.

  13. Freeze-Thaw Cycle Test on Basalt, Diorite and Tuff Specimens with the Simulated Ground Temperature of Antarctica

    Science.gov (United States)

    Park, J.; Hyun, C.; Cho, H.; Park, H.

    2010-12-01

    Physical weathering caused by freeze-thaw action in cold regions was simulated with artificial weathering simulator in laboratory. Physical weathering of rock in cold regions usually depends on the temperature, rock type and moisture content. Then these three variables were considered in this study. The laboratory freeze-thaw tests were conducted on the three types of rocks, e.g. diorite, basalt and tuff, which are the major rock types around Sejong Station, King George Island, Antarctica. Nine core samples composed of three samples from each rock type were prepared in NX core, and 50 cycles of freeze-thaw test was carried out under dried and saturated water conditions. In this study, the physical weathering of rocks was investigated after each 10 cycles by measuring P-wave velocity, bulk density, effective porosity, Schmidt hardness and uniaxial compression strength(UCS). The experimental result of the diorite and the tuff specimens showed that P-wave velocity, bulk density, effective porosity, Schmidt hardness and UCS were gradually decreased as weathering progresses, but the result of the basalt specimens did not show typical trends due to the characteristics of irregular pore distribution and various pore sizes. Scanning electron microscopy(SEM) photographs of diorite, basalt and tuff specimens weathered in dried and saturated conditions were also acquired to investigate the role of water during physical weathering processes. The number and size of microcracks were increased as weathering progresses. This work was supported by the National Research Foundation of Korea(NRF) Grant(NRF-2010-0027753).

  14. Fatigue test results of flat plate specimens with surface cracks and evaluation of crack growth in structural components

    International Nuclear Information System (INIS)

    Shibata, Katsuyuki; Yokoyama, Norio; Ohba, Toshihiro; Kawamura, Takaichi; Miyazono, Shohachiro

    1982-12-01

    Part-through surface cracks are most frequently observed in the inspection of structural components, and it is one of the important subjects in the assessment of safety to evaluate appropriately the growth of such cracks during the service life of structural components. Due to the complexity of the stress at the front free surface, the crack growth at the surface shows a different behavior from the other part. Besides, an effect of interaction is caused in the growth of multiple surface cracks. These effects should be included in the growth analysis of surface part-through cracks. Authors have carried out a series of fatigue tests on some kinds of pipes with multiple cracks in the inner surface, and subsequently the fatigue test of flat plate specimens, made of Type 304L stainless steel, with a single or double surface cracks was carried out to study the basic characteristics in the growth of multiple surface cracks. Based on the results of the flat plate test. the correction factors for the front free surface (Cs) and interaction (Ci) of surface cracks were derived quantitatively by the following empirical expressions; Cs = 0.824. Ci = (0.227(a/b) 2 (sec(PI X/2) - 1) + 1)sup(1/m). Using these two correction factors, a procedure to predict the growth of surface cracks was developed by applying the crack growth formula to both the thickness and surface directions. Besides, the crack growth predictions based on the procedure of ASME Code Sex. XI, and the above procedure without the correction of the free surface and interactions on the crack growth behaviors were compared with the test results of flat plate specimens. The crack growth behavior predicted by the procedure described in this report showed the best agreement with the test results in respects of the crack growth life and the change in the crack shape. The criteria of the ASME Code did not agree with the test results. (author)

  15. 10 CFR 26.153 - Using certified laboratories for testing urine specimens.

    Science.gov (United States)

    2010-01-01

    ... Workplace Drug Testing Programs [published in the Federal Register on April 11, 1988 (53 FR 11970), and as... current certification status of laboratories is available from the Division of Workplace Programs, Center... relationship with the licensee's or other entity's MRO(s) that may be construed as a potential conflict of...

  16. Determination of the mechanical characteristics of irradiated metals from the results of microhardness tests

    International Nuclear Information System (INIS)

    Hofman, A.

    1999-01-01

    To predict the possibilities of using structural materials in nuclear and thermonuclear reactors, it is important to have data on changes of the mechanical characteristics and irradiation obtained from full-scale or simulation tests. Materials are irradiated in nuclear reactors with fast neutrons, the sources of high-energy neutrons with an energy of 14 MeV and the accelerators of charged particles. The restricted volumes for irradiation of these specimens in the systems and also the need to test large numbers of specimens under the same conditions make it necessary to reduce the size of irradiated specimens. To solve this problem, work is being carried out to develop various methods of testing miniature specimens, including tension extrusion of disc-shaped micro-specimens, microhardness, and the Charpy Method. In examination of the irradiation hardening of the materials, the main advantage of the microhardness method is that it makes it possible to examine small specimens. In single microhardness tests, only a small area of the irradiated specimens is examined. This makes it possible to increase the radiation dose and carry out subsequent tests of microhardness on the same specimens. The aim of this work was to determine the possibilities of using the microhardness measurement method for evaluating the mechanical characteristics of metallic materials. The comparison of the data, obtained in microhardness tests and in tensile loading specimens of 0Kh18N10Tsteel, irradiated with neutrons, shows the efficiency of the microhardness method as a tool for investigating the irradiation hardening of reactor materials

  17. Model-Based Structural Health Monitoring of Fatigue Damage Test-Bed Specimens

    Science.gov (United States)

    2011-11-15

    the hull welds or notches along component edges are good initial candidates for the hypothetical damage initiation areas. The branching process adds...to it off-center. The base plate and the stiffener plate are rigidly welded by a tungsten inert gas ( TIG ) weld . Three different crack paths...shown in Figure 9(a), an 18 in long stiffener plate has been welded to each of the tested plates with 0.625 in long discrete TIG welds at 5 locations

  18. Comparing Repaired and Undamaged Specimens Test Results of Post-Tensioned Beam to Column Connections

    OpenAIRE

    Mustafa Kaya

    2015-01-01

    Since, it is essential to provide homeless people by the earthquake with safe, habitable accommodation repairing medium and slight levels of damage at the connection parts should be undertaken. In order to prove that a repaired connection was sufficiently strong, a precast beam to column post tensioned connection was tested in three phases. In phase one, the middle level damage was observed at 6% drift at these connections. As a result of the extra loads applied, little d...

  19. Ductile Tearing Resistance Indexing of Automotive Grade DP 590 Steel Sheets: EWF Testing Using DENT Specimens

    Science.gov (United States)

    Sahoo, Subhadra; Padmapriya, N.; De, Partha Sarathi; Chakraborti, P. C.; Ray, S. K.

    2018-03-01

    The essential work of fracture (EWF) method has been explored for indexing the ductile tearing resistance of DP 590 automotive grade dual-phase steel sheet both in longitudinal (L-T) and transverse (T-L) orientations. The simplest possible test and analysis procedures have been adopted. The EWF method is found to be eminently suitable for routine quality control and product development purposes for such materials. Areas for further research for improving the experimental strategy are highlighted. For the investigated steel sheet, the estimated tearing resistance is found to be distinctly higher for the L-T orientation compared to the T-L orientation; the reason thereof merits further investigation.

  20. Recent advances on Charpy specimen reconstitution techniques

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J., E-mail: aandrade@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  1. Recent advances on Charpy specimen reconstitution techniques

    International Nuclear Information System (INIS)

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J.

    2017-01-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  2. Influence of the gripping fixture on the modified compact tension test results: Evaluation of the experiments on cylindrical concrete specimens

    Czech Academy of Sciences Publication Activity Database

    Holušová, T.; Lozano, M.; Canteli, A.; Komárková, T.; Kocáb, D.; Seitl, Stanislav

    2015-01-01

    Roč. 15, č. 2 (2015) ISSN 1804-4824 Institutional support: RVO:68081723 Keywords : Modified compact tension test * fracture parametr * Cementitious composites * Aramis measurement * grips Subject RIV: JL - Materials Fatigue, Friction Mechanics

  3. Numerical simulation of impact bend tests on araldite B and steel specimens

    International Nuclear Information System (INIS)

    Stoeckl, H.; Boehme, W.

    1983-09-01

    As a preliminary stage in the numerical simulation of impact bend tests on elastic-plastic sample materials some simpler experiments were calculated for this report, some of which occured without crack propagation, others with linear elastic crack propagation. These calculations were performed with an own program based on the method of finite differences and also with the finite element program ADINA. In the numerical models plane stress was assumed. Crack propagation was governed by a relation between crack velocity and stress intensity factor. As load input the measured hammer load was used in some cases, mass and initial velocity of the hammer in others. The sample looses contact to the anvils and to the hammer for some time, which had to be considered in model building. The stiffening of the model in the contact region caused by the discretization had to be compensated by springs inserted between the sample and the anvils. The simulation reproduces the experimentally observed behaviour of the sample quite well. Furthermore, additional information can be extracted from the experiment, e.g. concerning the partition of the impact energy. (orig.) [de

  4. Manufacturing method for intragranular stress corrosion cracking-induced test specimen for stainless steel pipeline

    International Nuclear Information System (INIS)

    Futagawa, Kiyoshi.

    1994-01-01

    In a manufacturing step for intragranular stress corrosion cracking-induced for stainless steel pipelines, pipe are abutted against with each other and welded, and a heat affected portion is applied with a sensitizing heat treatment. Further, a crevice jig is attached near the heat affected portion at the inner surface of the pipe and kept in a chlorine ion added water under high temperature and high pressure at a predetermined period of time. If tap water is used instead of purified water for C.P.T. test in a step of forming sample of IGSCC (intergranular stress corrosion cracking), since the chlorine ion concentration in the tap water is relatively high, TGSCC (intragranular stress corrosion crackings caused in all of the samples. A heat input and an interlayer temperature are determined for the material of stainless pipe having a carbon content of more than 0.05% so that the welding residual stress on the inner surface is applied as tension. The condition for the heat treatment is determined as, for example, 500degC x 24hr, and the samples are kept under water at high temperature and high pressure applied with chlorine ions for 500 to 200hours. As a result, since samples of TGSCC can be formed by utilizing the manufacturing step for IGSCC, there is no requirement for providing devices for applying environmental factors separately. (N.H.)

  5. Development of an evaluation method for fracture mechanical tests on small samples based on a cohesive zone model

    International Nuclear Information System (INIS)

    Mahler, Michael

    2016-01-01

    The safety and reliability of nuclear power plants of the fourth generation is an important issue. It is based on a reliable interpretation of the components for which, among other fracture mechanical material properties are required. The existing irradiation in the power plants significantly affects the material properties which therefore need to be determined on irradiated material. Often only small amounts of irradiated material are available for characterization. In that case it is not possible to manufacture sufficiently large specimens, which are necessary for fracture mechanical testing in agreement with the standard. Small specimens must be used. From this follows the idea of this study, in which the fracture toughness can be predicted with the developed method based on tests of small specimens. For this purpose, the fracture process including the crack growth is described with a continuum mechanical approach using the finite element method and the cohesive zone model. The experiments on small specimens are used for parameter identification of the cohesive zone model. The two parameters of the cohesive zone model are determined by tensile tests on notched specimens (cohesive stress) and by parameter fitting to the fracture behavior of smalls specimens (cohesive energy). To account the different triaxialities of the specimens, the cohesive stress is used depending on the triaxiality. After parameter identification a large specimen can be simulated with the cohesive zone parameters derived from small specimens. The predicted fracture toughness of this big specimen fulfills the size requirements in the standard (ASTM E1820 or ASTM E399) in contrast to the small specimen. This method can be used for ductile and brittle material behavior and was validated in this work. In summary, this method offers the possibility to determine the fracture toughness indirectly based on small specimen testing. Main advantage is the low required specimen volume. Thereby massively

  6. Comparison of fracture toughness values from large-scale pipe system tests and C(T) specimens

    International Nuclear Information System (INIS)

    Olson, R.; Scott, P.; Marschall, C.; Wilkowski, G.

    1993-01-01

    Within the International Piping Integrity Research Group (IPIRG) program, pipe system experiments involving dynamic loading with intentionally circumferentially cracked pipe were conducted. The pipe system was fabricated from 406-mm (16-inch) diameter Schedule 100 pipe and the experiments were conducted at 15.5 MPa (2,250 psi) and 288 C (550 F). The loads consisted of pressure, dead-weight, thermal expansion, inertia, and dynamic anchor motion. Significant instrumentation was used to allow the material fracture resistance to be calculated from these large-scale experiments. A comparison of the toughness values from the stainless steel base metal pipe experiment of standard quasi-static and dynamic C(T) specimen tests showed the pipe toughness value was significantly lower than that obtained from C(T) specimens. It is hypothesized that the cyclic loading from inertial stresses in this pipe system experiment caused local degradation of the material toughness. Such effects are not considered in current LBB or pipe flaw evaluation criteria. 4 refs., 14 figs., 1 tab

  7. Qualitative risk assessment during polymer mortar test specimens preparation - methods comparison

    Science.gov (United States)

    Silva, F.; Sousa, S. P. B.; Arezes, P.; Swuste, P.; Ribeiro, M. C. S.; Baptista, J. S.

    2015-05-01

    Polymer binder modification with inorganic nanomaterials (NM) could be a potential and efficient solution to control matrix flammability of polymer concrete (PC) materials without sacrificing other important properties. Occupational exposures can occur all along the life cycle of a NM and “nanoproducts” from research through scale-up, product development, manufacturing, and end of life. The main objective of the present study is to analyse and compare different qualitative risk assessment methods during the production of polymer mortars (PM) with NM. The laboratory scale production process was divided in 3 main phases (pre-production, production and post-production), which allow testing the assessment methods in different situations. The risk assessment involved in the manufacturing process of PM was made by using the qualitative analyses based on: French Agency for Food, Environmental and Occupational Health & Safety method (ANSES); Control Banding Nanotool (CB Nanotool); Ecole Polytechnique Fédérale de Lausanne method (EPFL); Guidance working safely with nanomaterials and nanoproducts (GWSNN); Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro, Italy method (ISPESL); Precautionary Matrix for Synthetic Nanomaterials (PMSN); and Stoffenmanager Nano. It was verified that the different methods applied also produce different final results. In phases 1 and 3 the risk assessment tends to be classified as medium-high risk, while for phase 2 the more common result is medium level. It is necessary to improve the use of qualitative methods by defining narrow criteria for the methods selection for each assessed situation, bearing in mind that the uncertainties are also a relevant factor when dealing with the risk related to nanotechnologies field.

  8. Qualitative risk assessment during polymer mortar test specimens preparation - methods comparison

    International Nuclear Information System (INIS)

    Silva, F; Sousa, S P B; Ribeiro, M C S; Arezes, P; Swuste, P; Baptista, J S

    2015-01-01

    Polymer binder modification with inorganic nanomaterials (NM) could be a potential and efficient solution to control matrix flammability of polymer concrete (PC) materials without sacrificing other important properties. Occupational exposures can occur all along the life cycle of a NM and “nanoproducts” from research through scale-up, product development, manufacturing, and end of life. The main objective of the present study is to analyse and compare different qualitative risk assessment methods during the production of polymer mortars (PM) with NM. The laboratory scale production process was divided in 3 main phases (pre-production, production and post-production), which allow testing the assessment methods in different situations. The risk assessment involved in the manufacturing process of PM was made by using the qualitative analyses based on: French Agency for Food, Environmental and Occupational Health and Safety method (ANSES); Control Banding Nanotool (CB Nanotool); Ecole Polytechnique Fédérale de Lausanne method (EPFL); Guidance working safely with nanomaterials and nanoproducts (GWSNN); Istituto Superiore per la Prevenzione e la Sicurezza del Lavoro, Italy method (ISPESL); Precautionary Matrix for Synthetic Nanomaterials (PMSN); and Stoffenmanager Nano. It was verified that the different methods applied also produce different final results. In phases 1 and 3 the risk assessment tends to be classified as medium-high risk, while for phase 2 the more common result is medium level. It is necessary to improve the use of qualitative methods by defining narrow criteria for the methods selection for each assessed situation, bearing in mind that the uncertainties are also a relevant factor when dealing with the risk related to nanotechnologies field. (paper)

  9. The feasibility of small size specimens for testing of environmentally assisted cracking of irradiated materials and of materials under irradiation in reactor core

    International Nuclear Information System (INIS)

    Toivonen, A.; Moilanen, P.; Pyykkoenen, M.; Taehtinen, S.; Rintamaa, R.; Saario, T.

    1998-01-01

    Environmentally assisted cracking (EAC) of core materials has become an increasingly important issue of downtime and maintenance costs in nuclear power plants. Small size specimens are necessary in stress corrosion testing of irradiated materials because of difficulties in handling high dose rate materials and because of restricted availability of the materials. The drawback of using small size specimens is that in some cases they do not fulfil the requirements of the relevant testing standards. Recently VTT has developed J-R testing with irradiated and non-irradiated sub size 3 PB specimens, both in inert and in LWR environments. Also, a new materials testing system which will enable simultaneous multiple specimen testing both in laboratory conditions and in operating reactor core is under development. The new testing system will utilize Charpy and sub size 3 PB specimens. The feasibility study of the system has been carried out using different materials. Fracture resistance curves of a Cu-Zr-Cr alloy are shown to be independent of the specimen geometry and size, to some extent. Results gained from tests in simulated boiling water reactor (BWR) water are presented for sensitized SIS 2333 stainless steel. The experimental results indicate that the size of the plastic zone or stress triaxiality must be further studied although no significant effect on the environmentally assisted crack growth rate was observed. (orig.)

  10. The feasibility of small size specimens for testing of environmentally assisted cracking of irradiated materials and of materials under irradiation in reactor core

    Energy Technology Data Exchange (ETDEWEB)

    Toivonen, A.; Moilanen, P.; Pyykkoenen, M.; Taehtinen, S.; Rintamaa, R.; Saario, T. [Valtion Teknillinen Tutkimuskeskus, Espoo (Finland)

    1998-11-01

    Environmentally assisted cracking (EAC) of core materials has become an increasingly important issue of downtime and maintenance costs in nuclear power plants. Small size specimens are necessary in stress corrosion testing of irradiated materials because of difficulties in handling high dose rate materials and because of restricted availability of the materials. The drawback of using small size specimens is that in some cases they do not fulfil the requirements of the relevant testing standards. Recently VTT has developed J-R testing with irradiated and non-irradiated sub size 3 PB specimens, both in inert and in LWR environments. Also, a new materials testing system which will enable simultaneous multiple specimen testing both in laboratory conditions and in operating reactor core is under development. The new testing system will utilize Charpy and sub size 3 PB specimens. The feasibility study of the system has been carried out using different materials. Fracture resistance curves of a Cu-Zr-Cr alloy are shown to be independent of the specimen geometry and size, to some extent. Results gained from tests in simulated boiling water reactor (BWR) water are presented for sensitized SIS 2333 stainless steel. The experimental results indicate that the size of the plastic zone or stress triaxiality must be further studied although no significant effect on the environmentally assisted crack growth rate was observed. (orig.)

  11. Plane strain fracture toughness tests on 2.4 and 3.9-inch-thick maraging steel specimens at various yield strength levels.

    Science.gov (United States)

    Fisher, D. M.; Repko, A. J.

    1972-01-01

    Tests of bend and compact specimens were conducted according to ASTM Tentative Method E 399-70T on a 200 grade maraging steel over a range of yield strengths from 123 to 234 ksi. The toughness of any given yield strength level was greater for the overaged condition than for the underaged. Some results which met the specimen size requirements of the method were distinctly lower than corresponding results from larger specimens. Inconsistencies in both validation and invalidation of results by the requirement for linearity of the test record were also noted.

  12. AGR steel corrosion monitoring schemes: progress on off-site testing of coupon specimens to end of 1985: Pt. 1

    International Nuclear Information System (INIS)

    Whittle, I.; Meredith, M.E.

    1988-03-01

    Off-site Advanced Gas-cooled Reactor steel corrosion monitoring through experiments on mild steel coupon specimens is reported. The appearance of all mild steel coupons oxidised over the temperature range 375 to 450 0 C is consistent with what is expected for the appropriate silicon content, temperature and in the gas mixes used. Likewise, weight gain data from the tests is as expected and where linear (breakaway) oxidation kinetics are in evidence, measured rates are within one standard deviation of the mean oxidation rates predicted by the 1/R model. Also, data relating mean breakaway oxide thickness to weight gain is in good agreement with the currently recommended relationship of 1 mg cm -2 weight gain = 6.72 μm oxide thickness. The observed oxidation behaviour of the off-site mild steel coupons is consistent with the most recent design data. (author)

  13. Nanostructural evolution in surveillance test specimens of a commercial nuclear reactor pressure vessel studied by three-dimensional atom probe and positron annihilation

    International Nuclear Information System (INIS)

    Toyama, T.; Nagai, Y.; Tang, Z.; Hasegawa, M.; Almazouzi, A.; Walle, E. van; Gerard, R.

    2007-01-01

    The nanostructural evolution of irradiation-induced Cu-rich nanoprecipitates (CRNPs) and vacancy clusters in surveillance test specimens of in-service commercial nuclear reactor pressure vessel steel welds of Doel-1 and Doel-2 are revealed by combining the three-dimensional local electrode atom probe and positron annihilation techniques. In both medium (0.13 wt.%) and high (0.30 wt.%) Cu welds, the CRNPs are found to form readily at the very beginning of the reactor lifetime. Thereafter, during the subsequent 30 years of operation, the residual Cu concentration in the matrix shows a slight decrease while the CRNPs coarsen. On the other hand, small vacancy clusters of V 3 -V 4 start appearing after the initial Cu precipitation and accumulate steadily with increasing neutron dose. The observed nanostructural evolution is shown to provide unique and fundamental information about the mechanisms of the irradiation-induced embrittlement of these specific materials

  14. Mechanical Fatigue Testing of High Burnup Fuel for Transportation Applications

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Wang, Hong [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-05-01

    This report describes testing designed to determine the ability of high burnup (HBU) (>45 GWd/MTU) spent fuel to maintain its integrity under normal conditions of transportation. An innovative system, Cyclic Integrated Reversible-bending Fatigue Tester (CIRFT), has been developed at Oak Ridge National Laboratory (ORNL) to test and evaluate the mechanical behavior of spent nuclear fuel (SNF) under conditions relevant to storage and transportation. The CIRFT system is composed of a U-frame equipped with load cells for imposing the pure bending loads on the SNF rod test specimen and measuring the in-situ curvature of the fuel rod during bending using a set up with three linear variable differential transformers (LVDTs).

  15. Effect of CT Specimen Thickness on the Mechanical Characteristics at the Crack Tip of Stress Corrosion Cracking in Ni-based Alloys

    Science.gov (United States)

    Yinghao, Cui; He, Xue; Lingyan, Zhao

    2017-12-01

    It’s important to obtain accurate stress corrosion crack(SCC) growth rate for quantitative life prediction of components in nuclear power plants. However, the engineering practice shows that the crack tip constraint effect has a great influence on the mechanical properties and crack growth rate of SCC at crack tip. To study the influence of the specimen thickness on the crack tip mechanical properties of SCC, the stress, strain and C integral at creep crack tip are analyzed under different specimens thickness. Results show that the cracked specimen is less likely to crack due to effect of crack tip constraint. When the thickness ratio B/W is larger than 0.1, the crack tip constraint is almost ineffective. Value of C integral is the largest when B/W is 0.25. Then specimen thickness has little effect on the value of C integral. The effect of specimen thickness on the value of C integral is less significant at higher thickness ratio.

  16. The covariant form of Maxwell equations for the fast simulation of the eddy current non destructive testing of complex specimens

    International Nuclear Information System (INIS)

    Caire, Francois

    2014-01-01

    This PhD work concerns the development of fast numerical tools, dedicated to the computation of the electromagnetic interaction between a low frequency 3D current source and a complex conductor, presenting rough interfaces and/or conductivity variations. The main application concerns the simulation of the Eddy Current nondestructive testing process applied to complex specimens. Indeed, the semi-analytical models available today are restricted to canonical geometries. The proposed method is based on the covariant form of Maxwell's equations, which translates the physical equations and relationships in a non-orthogonal coordinate system depending on the geometry of the specimen. Historically, this method (Curvilinear Coordinate Method, CCM or C-method) has been developed in the framework of optical applications, particularly for the characterization of diffraction gratings. Here, we transpose this formalism into the quasi-static regime and we extend the Second Order Vector Potential formalism, initially dedicated to orthonormal curvilinear coordinates systems, to general curvilinear coordinate systems. Thanks to this change of base, we are able to determine numerically a set of modal solutions of the source-free Maxwell equations in the new coordinate system introduced, and this allows us to represent the unknown fields as modal expansions in source-free domains. Then, the coefficients of these expansions are computed by introducing the source fields and by enforcing the boundary conditions that the total fields must verify at interfaces between the different media. In order to tackle the case of a layered conductor presenting rough interfaces, the generalized SOVP formalism is coupled with a recursive routine called the S-matrix algorithm. On the other hand, the application case of a complex shape specimen with depth-varying physical properties is treated by coupling the modal method we developed with a high-order numerical method: pseudo-spectral method. The

  17. The influence of the epoxy interlayer on the assessment of failure conditions of push-out test specimens

    Czech Academy of Sciences Publication Activity Database

    Klusák, Jan; Helincks, P.; Seitl, Stanislav; De Corte, W.; Boel, V.; De Schutter, G.

    525-526, č. 1 (2013), s. 61-64 ISSN 1013-9826 R&D Projects: GA ČR GAP108/10/2049; GA ČR(CZ) GAP105/11/1551 Institutional support: RVO:68081723 Keywords : push-out test * generalized fracture mechanics * failure initiation * steel-concrete joint * epoxy adhesive layer Subject RIV: JL - Materials Fatigue, Friction Mechanics

  18. Environmental charging of spacecraft-tests of thermal control materials for use on the global positioning system flight space vehicle. Part 2: Specimen 6 to 9

    Science.gov (United States)

    Stevens, N. J.; Berkopec, F. D.; Blech, R. A.

    1976-01-01

    The NASA/USAF program on the Environmental Charging of Spacecraft Surfaces consists, in part, of experimental efforts directed toward evaluating the response of materials to the environmental charged particle flux. Samples of thermal blankets of the type to be used on the Global Positioning System Flight Space Vehicles were tested to determine their response to electron flux. The primary result observed was that no discharges were obtained with the quartz-fiber-fabric-covered multilayer insulation specimen. The taped aluminized polyester grounding system used on all specimens did not appear to grossly deteriorate with time; however, the specimens require specific external pressure to maintain constant grounding system resistance.

  19. Development of Universal Methodology of Specimen Free Nondestructive Inspection (Control) of Mechanical Properties of NPP Equipment Metal in all Stages of Lifetime

    International Nuclear Information System (INIS)

    Bakirov, M.; Chubarov, S.; Frolov, I.; Kiselev, I.; Gastrock, J.; Dripke, M.

    2011-01-01

    indications on tensile yield stress elevation due to hardening and also loss in ductility. The work-hardening index may be easily obtained, giving information on the ability of the material (e.g. pressure vessel steel and weld) to deform plastically without brittle fracture. Taking into account the experience of the Center of Material Science and Lifetime Management Ltd. (CMSLM Ltd.) in the use of methods of hardness testing for the inspection of the equipment of NPP of Russian manufacture in Russia, Germany, Czech, Slovakia, Bulgaria, and also similar successful works in this direction in USA (Oakridge), to Czech (NRI Rez) and other countries, it can be seen that the most promising direction in the field of specimen-free inspection of mechanical properties by use of hardness and hardness-related characteristics is use of the kinetic indentation method (KIM, ABIT). This method is based on recording the process of elastoplastic deformation caused by the indentation of a ball indenter. This method allows one to obtain, besides hardness values, tensile properties, elongation, work hardening coefficient, true-stress/true strain diagrammes which normally required the destructive testing of small specimens. However, till now there is no universal method of interpreting the information obtained, although it is generally known that irradiation causes a loss in ductility and increase in hardness and lowering of the work-hardening coefficient. Thus, it is necessary to develop a uniform methodology of using KIM, ABIT with reference to the inspection of materials which will allow unifying the inspection of materials of various classes of the equipment of NPP over all stages of life cycle. With the purpose of introduction of such a methodology it is necessary to develop and realize the program in the frames of IAEA with the above name. (author)

  20. Determination of a cohesive law for delamination modelling - Accounting for variation in crack opening and stress state across the test specimen width

    DEFF Research Database (Denmark)

    Joki, R. K.; Grytten, F.; Hayman, Brian

    2016-01-01

    by differentiating the fracture resistance with respect to opening displacement at the initial location of the crack tip, measured at the specimen edge. 2) Extend the bridging law to a cohesive law by accounting for crack tip fracture energy. 3) Fine-tune the cohesive law through an iterative modelling approach so......The cohesive law for Mode I delamination in glass fibre Non-Crimped Fabric reinforced vinylester is determined for use in finite element models. The cohesive law is derived from a delamination test based on DCB specimens loaded with pure bending moments taking into account the presence of large...... that the changing state of stress and deformation across the width of the test specimen is taken into account. The changing state of stress and deformation across the specimen width is shown to be significant for small openings (small fracture process zone size). This will also be important for the initial part...

  1. Analysis of surface roughening behavior of 6063 aluminum alloy by tensile testing of a trapezoidal uniaxial specimen

    Energy Technology Data Exchange (ETDEWEB)

    Cai, Yang [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150090 (China); Wang, Xiaosong, E-mail: hitxswang@hit.edu.cn [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150090 (China); National Key Laboratory of Precision Hot Processing of Metals, Harbin Institute of Technology, Harbin 150001 (China); Yuan, Shijian [School of Materials Science and Engineering, Harbin Institute of Technology, Harbin 150090 (China); National Key Laboratory of Precision Hot Processing of Metals, Harbin Institute of Technology, Harbin 150001 (China)

    2016-08-30

    To determine the quantitative relationship between surface roughness and strain, the surface roughening behavior of a 6063 aluminum alloy tube was examined by tensile testing of a trapezoidal uniaxial specimen, that can provide a continuous strain distribution after tensile deformation. The surface roughness was measured using a laser scanning confocal microscope to reflect the degree of roughening. The microstructure and surface morphology were examined using electron back-scattered diffraction and in-situ scanning electron microscopy to determine the grain orientation and surface topography evolution. The surface roughness increased with strain when the strain was less than 0.067 and then decreased slightly, with a maximum surface roughness of 23.73 µm. Inhomogeneous deformation at the grain boundaries and inside the grains was enhanced with increasing strain, resulting in an increase of surface roughness when the strain was below a critical value. As the strain increased, a greater number of slip systems contributed to the further deformation. Thus, the strain became more homogeneous, and accordingly, the surface roughness slightly decreased.

  2. Effects of tensile test parameters on the mechanical properties of a bimodal Al–Mg alloy

    International Nuclear Information System (INIS)

    Magee, Andrew; Ladani, Leila; Topping, Troy D.; Lavernia, Enrique J.

    2012-01-01

    The properties of aluminum alloy (AA) 5083 are shown to be significantly improved by grain size reduction through cryomilling and the incorporation of unmilled Al particles into the material, creating a bimodal grain size distribution consisting of coarse grains in a nanocrystalline matrix. To provide insight into the mechanical behavior and ultimately facilitate engineering applications, the present study reports on the effects of coarse grain ratio, anisotropy, strain rate and specimen size on the elastic–plastic behavior of bimodal AA 5083 evaluated in uniaxial tension tests using a full-factorial experiment design. To determine the governing failure mechanisms under different testing conditions, the specimens’ failure surfaces were analyzed using optical and electron microscopy. The results of the tests were found to conform to Joshi’s plasticity model. Significant anisotropy effects were observed, in a drastic reduction in strength and ductility, when tension was applied perpendicular (transverse) to the direction of extrusion. These specimens also exhibited a smooth, flat fracture surface morphology with a significantly different surface texture than specimens tested in the axial direction. It was found that decreasing specimen thickness and strain rate served to increase both the strength and ductility of the material. The failure surface morphology was found to differ between specimens of different thicknesses.

  3. Standard Test Methods for Determining Mechanical Integrity of Photovoltaic Modules

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 These test methods cover procedures for determining the ability of photovoltaic modules to withstand the mechanical loads, stresses and deflections used to simulate, on an accelerated basis, high wind conditions, heavy snow and ice accumulation, and non-planar installation effects. 1.1.1 A static load test to 2400 Pa is used to simulate wind loads on both module surfaces 1.1.2 A static load test to 5400 Pa is used to simulate heavy snow and ice accumulation on the module front surface. 1.1.3 A twist test is used to simulate the non-planar mounting of a photovoltaic module by subjecting it to a twist angle of 1.2°. 1.1.4 A cyclic load test of 10 000 cycles duration and peak loading to 1440 Pa is used to simulate dynamic wind or other flexural loading. Such loading might occur during shipment or after installation at a particular location. 1.2 These test methods define photovoltaic test specimens and mounting methods, and specify parameters that must be recorded and reported. 1.3 Any individual mech...

  4. High-Throughput Testing of Urogenital and Extragenital Specimens for Detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae with Cobas® CT/NG.

    Science.gov (United States)

    Marlowe, Elizabeth M; Hardy, David; Krevolin, Mark; Gohl, Peter; Bertram, Alexander; Arcenas, Rodney; Seiverth, Britta; Schneider, Tanja; Liesenfeld, Oliver

    2017-09-01

    We compared the analytical and clinical performance of cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems with the Cobas ® 4800 CT/NG Test from urogenital and extragenital specimens in over 12,000 specimens from both male and female subjects in Germany and the United States. The analytical sensitivity was ≤40 EB/ml for Chlamydia trachomatis (CT) and ≤1 CFU/ml for Neisseria gonorrhoeae (NG). Using clinical specimens, the overall percent agreement with the Cobas ® 4800 CT/NG Test was >98.5%. Across urogenital specimens, there were 93 discrepant specimens; 76 (93.8%) of 81 CT discrepant specimens were 6800+/4800- and 10 (83.3%) of 12 NG discrepant specimens were 6800+/4800-. Sequencing verified CT results for 45 (61.6%) of 73 samples positive by 6800 and 1 (20%) of 5 positive by 4800. Similarly, 7 (70.0%) of 10 NG samples positive by 6800 and 1 of 2 positive by 4800 were confirmed by sequencing. Among discrepant extragenital specimens (all 6800+/4800-), 7 (50%) of 14 oropharyngeal and 23 (76.7%) of 30 anorectal CT discordant samples were confirmed as CT positive by sequencing; all 8 anorectal and 20 (90.9%) of 22 oropharyngeal NG discordant results were also confirmed as NG positive. In conclusion, Cobas ® CT/NG for use on the Cobas ® 6800/8800 Systems provides high-throughput automated solutions for sexually transmitted infection (STI) screening programs.

  5. Mechanical test for fuel assembly spacer grid

    International Nuclear Information System (INIS)

    Kang, Heung Seok; Jeong, Yeon Ho; Song, Kee Nam; Kim, Hyung Kyu; Yoon, Kyung Ho; Bang, Je Keun.

    1997-06-01

    In order to propose some tests for a new spacer grid, the grid mechanical tests performed by ABB-CE, KWU and Westinghouse have been investigated. It is known that a static compression test, a dynamic impact test, and a grid spring characteristic test were commonly carried out by the vendors when a prototype spacer grid was developed. The static compression test is to measure the stresses on the strips as well as to obtain the grid stiffness. The dynamic impact test is to get some basic data for accident analysis such as impact stiffness, impact strength, and coefficient of restitution. Since each fuel vendor has his theory on an accident analysis, every vendor employs his particular method for the dynamic impact test. The dynamic impact test can be divided into two in accordance with the number of impact face, and the duration of impact pulse. One is an one-sided impact test and the other is an through-gird impact test. The duration of the impact pulse for the former is considerably shorter than the latter. Therefore, the grid can endure much higher load under the one-sided impact condition than under the through-grid impact condition. The grid spring characteristic test is to obtain a force versus deflection curve. This curve is very important in designing the spacer grid to provide fuel rods with a sound supports in core. (author). 18 tabs., 26 figs

  6. Development of a Small Punch Test Technique for an Evaluation of the Mechanical Properties of Irradiated Materials in a Hot Cell

    International Nuclear Information System (INIS)

    Kim, Do-Sik; Ahn, Sang-Bok; Yoo, Byung-Ok; Choo, Yong-Sun; Hong, Kwon-Pyo

    2006-01-01

    Miniaturized specimens have been widely used to evaluate the mechanical properties of steels and plastics. Especially for a study on the irradiation effects in nuclear materials, the small specimen test techniques have attracted considerable attention. Therefore, it is essential that the test techniques be developed and verified to extract the mechanical properties information from small specimens. Among the test techniques using small specimens, the small punch (SP) test technique using small disc-sized specimen has been successfully used to estimate the tensile properties (yield strength and ultimate tensile strength), DBTT (ductile-brittle transition temperature), fracture toughness and creep properties of metals irradiated in a reactor or a proton accelerator. In this paper, the existing SP test techniques are reviewed and summarized. In addition, the information on the development of the SP test procedure is obtained to evaluate the radiation effects on the mechanical properties of nuclear materials in a hot cell

  7. Temperature buffer test. Hydro-mechanical and chemical/ mineralogical characterizations

    Energy Technology Data Exchange (ETDEWEB)

    Aakesson, Mattias; Olsson, Siv; Dueck, Ann; Nilsson, Ulf; Karnland, Ola [Clay Technology AB, Lund (Sweden); Kiviranta, Leena; Kumpulainen, Sirpa [BandTech Oy, Helsinki (Finland); Linden, Johan [Aabo Akademi, Aabo (Finland)

    2012-01-15

    TEM), iron oxidation state (Moessbauer spectroscopy). The retention tests, the CEC-determinations, the chemical analyses by ICP, and the mineralogical analyses by XRD and FTIR were performed on bulk samples as well as on a Na-converted fine fraction (<0.5 {mu}m). The latter fraction was subjected also to TEM analyses. The hydro-mechanical characterizations of the bentonite resulted in the following observations: i) compared to the reference material no large deviation was seen in the retention curves for the Na converted fine fraction of the material from the innermost positions, and for the bulk material from the same positions a marked deviation was observed for equilibrium with RH = 97%; ii) a reduction in swelling pressure was observed on re-saturated samples from the field experiment, especially on those from the innermost part. Measured hydraulic conductivity values were generally scattered, but displayed a tendency with increased values on re-saturated specimens drilled from the innermost part, and a similar tendency was also observed on ground and re-compacted specimens and specimens prepared from dried material; iii) the triaxial test performed on the one specimen from the inner part demonstrated a brittle behaviour involving high stiffness, high shear strength, and low strain at failure; and iv) the unconfined compression tests demonstrated a reduced strain at failure on all specimens from the field material, and also a reduced maximum deviator stress on the re-saturated specimens from the innermost position. The chemical/mineralogical characterization indicated that: i) sulfate was redistributed under the thermal and hydration gradients that were prevalent during the test. Anhydrite accumulated at some distance from the heater, whereas gypsum was dissolved in the peripheral parts of the buffer where water was supplied; ii) cristobalite was dissolved at the bentonite/heater contact; iii) calcite was dissolved in the warmest parts of the block; iv

  8. Determination of necking time in tensile test specimens, under high-temperature creep conditions, subjected to distribution of stresses over the cross-section

    Science.gov (United States)

    Lokoshchenko, A.; Teraud, W.

    2018-04-01

    The work describes an experimental research of creep of cylindrical tensile test specimens made of aluminum alloy D16T at a constant temperature of 400°C. The issue to be examined was the necking at different values of initial tensile stresses. The use of a developed noncontacting measuring system allowed us to see variations in the specimen shape and to estimate the true stress in various times. Based on the obtained experimental data, several criteria were proposed for describing the point of time at which the necking occurs (necking point). Calculations were carried out at various values of the parameters in these criteria. The relative interval of deformation time in which the test specimen is uniformly stretched was also determined.

  9. Fractographic examination of HT-9 and 9Cr-1Mo Charpy specimens irradiated in the AD-2 test

    International Nuclear Information System (INIS)

    Gelles, D.S.; Hu, W.L.

    1983-01-01

    Fracture surface topologies have been examined using scanning electron microscopy for 20 selected half sized Charpy impact specimens of HT-9 and Modified 9Cr-1Mo in order to provide improved understanding of fracture toughness degradation as a result of irradiation for Path E alloys. The specimen matrix included unirradiated specimens and specimens irradiated in EBR-II in the AD-2 experiment. Also, hardness measurements have been made on selected irradiated Charpy specimens. The results of examinations indicate that irradiation hardening due to G-phase formation at 390 0 C is responsible for the large shift in ductile-to-brittle transition temperature (DBTT) found in HT-9. Toughness degradation in HT-9 observed following higher temperature irradiations is attributed to precipitation at delta ferrite stringers. Reductions in toughness as a consequence of irradiation in Modified 9Cr-1Mo are attributed to in-reactor precipitation of (V,Nb)C and M 23 C 6 . It is shown that crack propagation rates for ductile and brittle failure modes can be measured, that they differ by over an order of magnitude and that unexpected multiple shifts in fracture mode from ductile to brittle failure can be attributed to the effect of delta ferrite stringers on crack propagation rates

  10. A mechanical breathing simulator for respirator test

    International Nuclear Information System (INIS)

    Murata, Mikio; Ikezawa, Yoshio; Yoshida, Yoshikazu

    1976-01-01

    A mechanical breathing simulator has been developed to produce the human respiration for use in respirator test. The respirations were produced through the strokes of piston controlled by a rockerarm with adjustable fulcrum. The respiration rate was governed by motor-speed control, independent of the tidal volume achieved by adjustment of the piston stroke. By the breather, the simulated respirations for work rate 0, 208, 415, 622 and 830 kg-m/min could be produced through the typical dummy head. (auth.)

  11. Thermo-mechanical cementation effects in bentonite investigated by unconfined compression tests

    International Nuclear Information System (INIS)

    Dueck, Ann; Boergesson, Lennart; Karnland, Ola

    2010-01-01

    Document available in extended abstract form only. Mechanical properties of buffer material are included in the model used for predicting the physical behaviour of saturated buffer in the final disposal of spent nuclear fuel. One simple test where the mechanical properties can be quantified is the unconfined compression test. In this type of test the relation between stress and strain are determined from axial compression of a cylindrical specimen. In the project LOT the unconfined compression test was used to study the mechanical properties on field exposed buffer material. The results from these test series showed that specimens exposed to warm conditions had a significantly reduced strain at failure compared to reference material. Changes in mechanical properties may be due to incipient chemical changes in the material. However, the present study focuses on other possible sources for brittle failure behaviour. In this study the objective was to experimentally investigate if deviating stress-strain behaviour measured after temperature exposure could be explained by Thermo-Hydro-Mechanical processes. The word cementation is used as a general term for the process involving a change in mechanical properties including brittleness at failure. A relatively large number of specimens were tested representing sodium dominated and calcium dominated bentonites. Cylindrical specimens were compacted from air dry powder to a height and diameter of 20 mm. The main part of the specimens was put in a saturation device prior to the tests in order to ensure full saturation. After the saturation each sample was placed in a mechanical press where a constant rate of strain was applied axially to the specimens having no radial confinement. During the test the deformation and the applied force were measured by means of force and strain transducers. After failure the water content and density were determined. Test series were carried out for investigating the influence of for example

  12. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    International Nuclear Information System (INIS)

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B.

    2015-01-01

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer

  13. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer.

  14. qPCR-High resolution melt analysis for drug susceptibility testing of Mycobacterium leprae directly from clinical specimens of leprosy patients.

    Science.gov (United States)

    Araujo, Sergio; Goulart, Luiz Ricardo; Truman, Richard W; Goulart, Isabela Maria B; Vissa, Varalakshmi; Li, Wei; Matsuoka, Masanori; Suffys, Philip; Fontes, Amanda B; Rosa, Patricia S; Scollard, David M; Williams, Diana L

    2017-06-01

    Real-Time PCR-High Resolution Melting (qPCR-HRM) analysis has been recently described for rapid drug susceptibility testing (DST) of Mycobacterium leprae. The purpose of the current study was to further evaluate the validity, reliability, and accuracy of this assay for M. leprae DST in clinical specimens. The specificity and sensitivity for determining the presence and susceptibility of M. leprae to dapsone based on the folP1 drug resistance determining region (DRDR), rifampin (rpoB DRDR) and ofloxacin (gyrA DRDR) was evaluated using 211 clinical specimens from leprosy patients, including 156 multibacillary (MB) and 55 paucibacillary (PB) cases. When comparing the results of qPCR-HRM DST and PCR/direct DNA sequencing, 100% concordance was obtained. The effects of in-house phenol/chloroform extraction versus column-based DNA purification protocols, and that of storage and fixation protocols of specimens for qPCR-HRM DST, were also evaluated. qPCR-HRM results for all DRDR gene assays (folP1, rpoB, and gyrA) were obtained from both MB (154/156; 98.7%) and PB (35/55; 63.3%) patients. All PCR negative specimens were from patients with low numbers of bacilli enumerated by an M. leprae-specific qPCR. We observed that frozen and formalin-fixed paraffin embedded (FFPE) tissues or archival Fite's stained slides were suitable for HRM analysis. Among 20 mycobacterial and other skin bacterial species tested, only M. lepromatosis, highly related to M. leprae, generated amplicons in the qPCR-HRM DST assay for folP1 and rpoB DRDR targets. Both DNA purification protocols tested were efficient in recovering DNA suitable for HRM analysis. However, 3% of clinical specimens purified using the phenol/chloroform DNA purification protocol gave false drug resistant data. DNA obtained from freshly frozen (n = 172), formalin-fixed paraffin embedded (FFPE) tissues (n = 36) or archival Fite's stained slides (n = 3) were suitable for qPCR-HRM DST analysis. The HRM-based assay was also able to

  15. Hydraulic Apparatus for Mechanical Testing of Nuts

    Science.gov (United States)

    Hinkel, Todd J.; Dean, Richard J.; Hacker, Scott C.; Harrington, Douglas W.; Salazar, Frank

    2004-01-01

    The figure depicts an apparatus for mechanical testing of nuts. In the original application for which the apparatus was developed, the nuts are of a frangible type designed for use with pyrotechnic devices in spacecraft applications in which there are requirements for rapid, one-time separations of structures that are bolted together. The apparatus can also be used to test nonfrangible nuts engaged without pyrotechnic devices. This apparatus was developed to replace prior testing systems that were extremely heavy and immobile and characterized by long setup times (of the order of an hour for each nut to be tested). This apparatus is mobile, and the setup for each test can now be completed in about five minutes. The apparatus can load a nut under test with a static axial force of as much as 6.8 x 10(exp 5) lb (3.0 MN) and a static moment of as much as 8.5 x 10(exp 4) lb in. (9.6 x 10(exp 3) N(raised dot)m) for a predetermined amount of time. In the case of a test of a frangible nut, the pyrotechnic devices can be exploded to break the nut while the load is applied, in which case the breakage of the nut relieves the load. The apparatus can be operated remotely for safety during an explosive test. The load-generating portion of the apparatus is driven by low-pressure compressed air; the remainder of the apparatus is driven by 110-Vac electricity. From its source, the compressed air is fed to the apparatus through a regulator and a manually operated valve. The regulated compressed air is fed to a pneumatically driven hydraulic pump, which pressurizes oil in a hydraulic cylinder, thereby causing a load to be applied via a hydraulic nut (not to be confused with the nut under test). During operation, the hydraulic pressure is correlated with the applied axial load, which is verified by use of a load cell. Prior to operation, one end of a test stud (which could be an ordinary threaded rod or bolt) is installed in the hydraulic nut. The other end of the test stud passes

  16. Testing the foundations of quantum mechanics

    CERN Document Server

    Gisin, Nicolas; CERN. Geneva

    1999-01-01

    Quantum mechanics is certainly one of the most fascinating field of physics. In recent years, the new field of "quantum information processing" based on the most fundamental aspect of quantum mechanics, like linearity and entanglement, even increased and its peculiarities. In this series of 4 lectures we shall present some of the issues and experiments that test quantum theory. Entanglement leads, on the one hand side, to the measurement problem, to the EPR paradox and to quantum nonlocality ( distant systems). We will derive the Bell inequality, present experimental results that provide huge evidence in favor of quantum nonlocality and discuss some loopholes that are still open. On the other side, entanglement offers many new possibilities for information processing. Indeed, it provides means to carry out tasks that are either impossible classically (like quantum cryptography and quantum teleportation) or that would require significantly more steps to perform on a classical computer (like searching a databas...

  17. Formation of Gaps at the Specimen-Bar Interfaces in Numerical Simulations of Compression Hopkinson Bar Tests on Soft, Nearly Incompressible Materials

    Science.gov (United States)

    2010-09-01

    MISSISSIPPI MECHANICAL ENGINEERING A RAJENDRAN 201 CARRIER HALL UNIVERSITY MS 38677 2 UNIVERSITY OF CALIFORNIA SAN DIEGO ...extrapolation of the data given in Aihaiti and Hemley (10); the authors attribute this data to Dana Dattlebaum at Los Alamos National Laboratory...region bordering the centerline, about 6–8 specimen lengths back from the S-IB interface. From 164.2 to164.6 s (figures 19 and 20), the pressure

  18. Corrosion Characteristics of Inconel-600 at the NP(Cu)-HYBRID Decontamination Demonstration Test with HANARO FTL Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jun Young; Park, Sang Yoon; Won, Hui Jun; Kim, Seon Byeong; Choi, Wang Kyu; Moon, Jei Kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    An alkaline permanganate (AP) or nitric permanganate (NP) oxidative phase has been generally used to dissolve the chromium-rich oxide. AP is advantageous for the corrosion resistance, but increases the volume of secondary waste during the decontamination procedure. On the other hand, NP has a high corrosion rate but reduces secondary waste. For the safe use of an oxidative decontamination solution with high corrosive resistance and less amount of secondary waste are required. In this study, we modified NP oxidative decontamination solution by adding Cu{sup 2+} to reduce the corrosion rate. To evaluate the general corrosion characteristics, we measured the weight losses of selected specimens in an NP(Cu) and other solutions. The localized corrosion was observed using an optical microscope (OM). To compare the decontamination performance, we measured the contact dose rate of specimens treated in NP-HYBRID and NP(Cu)-HYBRID systems. The reduced corrosion characteristics of the Inconel-600 specimen in a NP(Cu) oxidative solution was observed in terms of generalized corrosion as well as localized corrosion. Less corrosion characteristics do not affect the performance of the overall decontamination compared to the NP-HYBRID process. Therefore, our results support that the NP(Cu)-HYBRID decontamination process is appropriate for the decontamination of the primary coolant system in a nuclear reactor.

  19. Laboratory rock mechanics testing manual. Public draft

    Energy Technology Data Exchange (ETDEWEB)

    Shuri, F S; Cooper, J D; Hamill, M L

    1981-10-01

    Standardized laboratory rock mechanics testing procedures have been prepared for use in the National Terminal Waste Storage Program. The procedures emphasize equipment performance specifications, documentation and reporting, and Quality Assurance acceptance criteria. Sufficient theoretical background is included to allow the user to perform the necessary data reduction. These procedures incorporate existing standards when possible, otherwise they represent the current state-of-the-art. Maximum flexibility in equipment design has been incorporated to allow use of this manual by existing groups and to encourage future improvements.

  20. The Development of Expansion Plug Wedge Test for Clad Tubing Structure Mechanical Property Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [ORNL; Jiang, Hao [ORNL

    2016-01-12

    To determine the tensile properties of irradiated fuel cladding in a hot cell, a simple test was developed at the Oak Ridge National Laboratory (ORNL) and is described fully in US Patent Application 20060070455, “Expanded plug method for developing circumferential mechanical properties of tubular materials.” This method is designed for testing fuel rod cladding ductility in a hot cell using an expandable plug to stretch a small ring of irradiated cladding material. The specimen strain is determined using the measured diametrical expansion of the ring. This method removes many complexities associated with specimen preparation and testing. The advantages are the simplicity of measuring the test component assembly in the hot cell and the direct measurement of the specimen’s strain. It was also found that cladding strength could be determined from the test results.

  1. Small punch tensile/fracture test data and 3D specimen surface data on Grade 91 ferritic/martensitic steel from cryogenic to room temperature.

    Science.gov (United States)

    Bruchhausen, Matthias; Lapetite, Jean-Marc; Ripplinger, Stefan; Austin, Tim

    2016-12-01

    Raw data from small punch tensile/fracture tests at two displacement rates in the temperature range from -196 °C to room temperature on Grade 91 ferritic/martensitic steel are presented. A number of specimens were analyzed after testing by means of X-ray computed tomography (CT). Based on the CT volume data detailed 3D surface maps of the specimens were established. All data are open access and available from Online Data Information Network (ODIN)https://odin.jrc.ec.europa.eu. The data presented in the current work has been analyzed in the research article "On the determination of the ductile to brittle transition temperature from small punch tests on Grade 91 ferritic-martensitic steel" (M. Bruchhausen, S. Holmström, J.-M. Lapetite, S. Ripplinger, 2015) [1].

  2. High temperature mechanical tests performed on doped fuels

    International Nuclear Information System (INIS)

    Dugay, C.; Mocellin, A.; Dehaudt, P.; Sladkoff, M.

    1998-01-01

    The high-temperature compressive deformation of large-grained UO 2 doped with metallic oxides has been investigated and compared with that of pure UO 2 with a standard microstructure. All the specimens are made from a single batch of UO 2 powder. Tests with constant applied strain rate of 20μm.min -1 show that Cr 2 O 3 additions cause a decrease in the flow stress of about 15 MPa compared with the reference material. When reduced in hydrogen at 1500 deg. C the specimens present a peak stress close to the flow stress of the pure UO 2 . Measurements of creep rates are made at 1500 deg. C at applied stresses varying from 20 to 70 MPa. Cr 2 O 3 additions increase the creep-rate, up to several orders of magnitude-change from the pure material to a doped one. All the doped materials exhibit power-law creep with exponents in the range of 4.9 to 6.3. The activation energy varies from 466 to 451 kJ/mol depending on the dopant concentration. The creep of the undoped material is divided into three regimes of deformation depending on stress. At low stresses the strain rate shows a second power dependence on stress. At high stress levels a higher stress dependence is observed. The creep power-law breaks down and an exponential law holds true at higher stresses. The activation energies are found to be 410 and 560 kJ/mol in the low- and high-stress regions respectively. The former value is in good agreement with the grain boundary diffusion energy in stoichiometric polycrystalline uranium dioxide and the latter corresponds to that found for self-diffusion energy of uranium. Creep behaviours are discussed in terms of deformation mechanisms. (author)

  3. Multiscale mechanics of TRIP-assisted multiphase steels: I. Characterization and mechanical testing

    International Nuclear Information System (INIS)

    Jacques, P.J.; Furnemont, Q.; Lani, F.; Pardoen, T.; Delannay, F.

    2007-01-01

    The mechanical behaviour of transformation-induced plasticity (TRIP)-assisted multiphase steels is addressed based on three different microstructures generated from the same steel grade. The mechanisms responsible for the work-hardening capacity and the resulting balance between strength and resistance to plastic localization are investigated at different length scales. The macroscopic mechanical response is determined by simple shear, uniaxial tension, Marciniak and equibiaxial tension supplemented by earlier tensile tests on notched and cracked specimens. It is shown that the transformation rate reaches a maximum for stress states intermediate between uniaxial tension and equibiaxial tension. At an intermediate length scale, the true in situ flow properties of the individual ferrite-bainite and retained austenite phases are determined by combining neutron diffraction and digital image correlation. This combined analysis elucidates the partitioning of stress and strain between the different constitutive phases. Based on these results, supplemented by transmission electron microscopy and electron backscattered diffraction observations, a general overview of the hardening behaviour of TRIP-assisted multiphase steels is depicted

  4. Post-irradiation mechanical tests on F82H EB and TIG welds

    International Nuclear Information System (INIS)

    Rensman, J.; Osch, E.V. van; Horsten, M.G.; D'Hulst, D.S.

    2000-01-01

    The irradiation behaviour of electron beam (EB) and tungsten inert gas (TIG) welded joints of the reduced-activation martensitic steel IEA heat F82H-mod. was investigated by neutron irradiation experiments in the high flux reactor (HFR) in Petten. Mechanical test specimens, such as tensile specimens and KLST-type Charpy impact specimens, were neutron irradiated up to a dose level of 2-3 dpa at a temperature of 300 deg. C in the HFR reactor in Petten. The tensile results for TIG and EB welds are as expected with practically no strain hardening capacity left. Considering impact properties, there is a large variation in impact properties for the TIG weld. The irradiation tends to shift the DBTT of particularly the EB welds to very high values, some cases even above +250 deg. C. PWHT of EB-welded material gives a significant improvement of the DBTT and USE compared to the as-welded condition

  5. Seismic functional qualification of active mechanical and electrical components based on shaking table testing

    International Nuclear Information System (INIS)

    Jurukovski, D.

    1999-01-01

    The seismic testing for qualification of one sample of the NPP Kozloduy Control Panel type YKTC was carried out under Research Contract no: 8008/Rl, entitled: 'Seismic Functional Qualification of Active Mechanical and Electrical Components Based on Shaking Table Testing'. The tested specimen was selected by the Kozloduy NPP staff, Section 'TIA-2' (Technical Instrumentation and Automatics), however the seismic input parameters were selected by the NPP Kozloduy staff, Section HTS and SC (Hydro-Technical Systems and Engineering Structures). The applied methodology was developed by the Institute of Earthquake Engineering and Engineering Seismology staff. This report presents all relevant items related to the selected specimen seismic testing for seismic qualification such as: description of the tested specimen, mounting conditions on the shaking table, selection of seismic input parameters and creation of seismic excitations, description of the testing equipment, explanation of the applied methodology, 'on line' and 'off line' monitoring of the tested specimen, functioning capabilities, discussion of the results and their presentation and finally conclusions and recommendations. In this partial project report, two items are presented. The first item presents a review of the existing and used regulations for performing of the seismic and vibratory withstand testing of electro-mechanical equipment. The selection is made based on MEA, IEEE, IEC and former Soviet Union regulations. The second item presents the abstracts of all the tests performed at the Institute of Earthquake Engineering and Engineering Seismology in Skopje. The selected regulations, the experience of the Institute that has been gathered for the last seventeen years and some theoretical and experimental research will be the basis for further investigations for development of a synthesised methodology for seismic qualification of differently categorized equipment for nuclear power plants

  6. Solid State Bonding Mechanics In Extrusion And FSW: Experimental Tests And Numerical Analyses

    International Nuclear Information System (INIS)

    Buffa, G.; Fratini, L.; Donati, L.; Tomesani, L.

    2007-01-01

    In the paper the authors compare the different solid state bonding mechanics for both the processes of hollow profiles extrusion and Friction Stir Welding (FSW), through the results obtained from a wide experimental campaign on AA6082-T6 aluminum alloys. Microstructure evaluation, tensile tests and micro-hardness measurements realized on specimens extracted by samples of the two processes are discussed also by means of the results obtained from coupled FEM simulation of the processes

  7. Development of Fast Fourier Transform (FFT) micro-mechanical simulations of concrete specimens characterized by micro-X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Giorla, Alain B. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    Concrete in Nuclear Power Plants (NPPs) can be exposed to a wide range of degradation phenomena. In the past years, the Light Water Reactor Sustainability (LWRS) program has investigated Radiation-Induced Volumetric Expansion (RIVE) as a potential degradation mechanism for concrete biological shields [Graves et al., 2014, Rosseel et al., 2016]. RIVE causes swelling and micro-mechanical damage in concrete due to the amorphization of mineral phases contained in the aggregates under neutron irradiation [Hilsdorf et al., 1978, Rosseel et al., 2016]. For long-term operations, it is critical to assess the durability of concrete after 60 or 80 years of exposure to NPP operating conditions against this phenomenon. RIVE is dependent on the composition of the aggregates used in concrete. Quartz-bearing aggregates are more sensitive to RIVE than calcite-bearing aggregates, for example. However, the aggregate composition of a specific plant is generally not explicitly given in the concrete formulation, which makes it nearly impossible to predict the resistance of that concrete to RIVE. Additional characterization is needed to identify the radiation-sensitive mineral phases contained in the aggregates.

  8. Application Anti Microbial Activity Test and Direct Inoculation of Urinary Specimen Test to Increase the Quality of Results and Decrease the Production Cost in Clinical Microbiology Laboratory, Sanglah General Hospital Hospital, Bali-Indonesia

    Directory of Open Access Journals (Sweden)

    Nyoman Sri-Budayanti

    2012-05-01

    Full Text Available Objective: Urinary tract infection (UTI is the most common bacterial infection in general practice and in hospitals. Fast and accurate urine culture and sensitivity test are needed for adequate therapy. Anti Microbial Activity test (AMA test that is used to detect the presence of antibiotics in urine specimens is not commonly used in clinical microbiology laboratories. Some laboratories are still using indirect inoculation technique using enriched media before inoculating onto the agar media. The aim of this research is to compare results of urinary examination of direct inoculation technique with AMA test with indirect inoculation technique without AMA test.Methods: A number of 210 urine specimens were collected in Clinical Microbiology Laboratory at Sanglah General Hospital within a time period between 16 June until 16 July 2009.Results: Antibiotics were detected in 40% of the urinary specimens; whereas 48.1% showed no evidence of UTI, that is negative AMA test and sterile urinary culture or colony growth < 105 CFU/ml. Only 11.9% of the specimens indicates urinary tract infections. The examination can be completed within 2-3 days which is shorter than indirect inoculation test which require 5-7 days. Direct inoculation technique can reduce the cost of production three-fold the costs require for an indirect inoculation test.Conclusions: Application of AMA test and direct inoculation technique can give results more rapidly, reliable and useful for clinicians. This also decrease the laboratory’s cost of production.

  9. Role of failure-mechanism identification in accelerated testing

    Science.gov (United States)

    Hu, J. M.; Barker, D.; Dasgupta, A.; Arora, A.

    1993-01-01

    Accelerated life testing techniques provide a short-cut method to investigate the reliability of electronic devices with respect to certain dominant failure mechanisms that occur under normal operating conditions. However, accelerated tests have often been conducted without knowledge of the failure mechanisms and without ensuring that the test accelerated the same mechanism as that observed under normal operating conditions. This paper summarizes common failure mechanisms in electronic devices and packages and investigates possible failure mechanism shifting during accelerated testing.

  10. Ropivacaine alters the mechanical properties of hamstring tendons: In vitro controlled mechanical testing of tendons from living donors.

    Science.gov (United States)

    Ollivier, M; Sbihi, J; Sbihi, A; Pithioux, M; Parratte, S; Argenson, J-N

    2017-11-01

    Intraarticular or periarticular injection of ropivacaine (RI) is an element of current knee surgery practices. The goal of this study was to determine the effects of RI on the mechanical properties of hamstring tendons. We hypothesized that RI would have a detrimental effect on the mechanical properties of periarticular soft tissues METHODS: A tensile test to failure was performed on 120 hamstring tendon segments harvested during ACL reconstruction surgery in 120 patients. Two sets of tensile tests were done. The first evaluated the effect of RI itself on the mechanical properties of tendons: 30 samples were soaked for 1hour in a 2% RI solution and compared to 30 samples soaked in a saline solution (control group). The second evaluated the effect of RI concentration on the mechanical properties of hamstring tendons: 30 samples were soaked for 1hour in a 2% RI solution and 30 samples were soaked in a 7.5% RI solution. In the first test, 29 samples from each group were analyzed as two samples (one in each group) failed at the grip interface. The specimens exposed to 2% RI had lower ultimate tensile strength (Δ=4.4MPa, P=0.001), strain energy (Δ=13MPa, P=0.001) and Young's modulus (Δ=1.6MPa, P=0.02) than the specimens in the control group. There was no significant difference in the strain at failure between groups (Δ=5%, P=0.3). In the second test, one specimen from the 7.5% RI group failed during the preloading and was excluded. There was no significant difference in terms of the load at failure and ultimate tensile stress (Δ=0.45MPa, P=0.6) and strain energy (Δ=0.49MPa, P=0.49) between the two groups. There were significant differences in terms of elongation at failure (Δ=28%, P=0.0003) and Young's modulus (Δ=2.6MPa, P=0.005), with the specimens exposed to 7.5% RI undergoing greater deformation and having a lower Young's modulus. While local RI injections are widely performed in clinical practice, the results of this in vitro study point to short

  11. The development of fuel pins and material specimens mixed loading irradiation test rig in the experimental fast reactor Joyo. The development of the fuel-material hybrid rig

    International Nuclear Information System (INIS)

    Oyamatsu, Yasuko; Someya, Hiroyuki

    2013-02-01

    In the experimental fast reactor Joyo, there were many tests using the irradiation rigs that it was possible to be set irradiation conditions for each compartment independently. In case of no alternative fuel element to irradiate after unloading the irradiated compartments, the irradiation test was restarted with the dummy compartment which the fuel elements was not mounted. If the material specimens are mounted in this space, it is possible to use the irradiation space effectively. For these reasons, the irradiation rig (hybrid rig) is developed that is consolidated with material specimens compartment and fuel elements compartment. Fuel elements and material specimens differ greatly with heat generation, so that the most important issue in developing of hybrid rig is being able to distribute appropriately the coolant flow which satisfies irradiation conditions. The following is described by this report. (1) It was confirmed that the flow distribution of loading the same irradiation rig with the compartment from which a flow demand differs could be satisfied. (2) It was confirmed that temperature setting range of hybrid rig could be equivalent to that of irradiation condition. (3) By standardizing the coolant entrance structure of the compartment lower part, the prospect which can perform easily recombination of the compartment from which a type differs between irradiation rigs was acquired. (author)

  12. Mechanical Properties of Commercial Carbon Fibers Using a Single Filament Tensile Test

    International Nuclear Information System (INIS)

    Joh, Han-Ik; Song, Hae Kyung; Ku, Bon-Cheol; Lee, Sungho; Kim, Ki-Young; Kang, Phil-Hyun

    2013-01-01

    In this study, mechanical properties of commercial carbon fibers were evaluated using a single filament tensile test with various fiber gauge lengths. Tensile strength increased significantly with a decreasing length of the test specimens possibly due to small defect sites. The compliance method provided more accurate moduli of the carbon fibers, removing system errors during the single filament tensile test. The Weibull modulus revealed that shorter specimens had an inhomogeneous defect distribution, leading to a higher tensile strength and its standard deviation. X-ray diffractograms of carbon fibers showed a similar crystallinity and orientation in spite of significant differences in the fiber modulus and strength, indicating that crystalline structure of the commercial carbon fibers used in the study was not attributable to the difference in their tensile properties.

  13. Mechanical testing of hydrogels in cartilage tissue engineering: beyond the compressive modulus.

    Science.gov (United States)

    Xiao, Yinghua; Friis, Elizabeth A; Gehrke, Stevin H; Detamore, Michael S

    2013-10-01

    Injuries to articular cartilage result in significant pain to patients and high medical costs. Unfortunately, cartilage repair strategies have been notoriously unreliable and/or complex. Biomaterial-based tissue-engineering strategies offer great promise, including the use of hydrogels to regenerate articular cartilage. Mechanical integrity is arguably the most important functional outcome of engineered cartilage, although mechanical testing of hydrogel-based constructs to date has focused primarily on deformation rather than failure properties. In addition to deformation testing, as the field of cartilage tissue engineering matures, this community will benefit from the addition of mechanical failure testing to outcome analyses, given the crucial clinical importance of the success of engineered constructs. However, there is a tremendous disparity in the methods used to evaluate mechanical failure of hydrogels and articular cartilage. In an effort to bridge the gap in mechanical testing methods of articular cartilage and hydrogels in cartilage regeneration, this review classifies the different toughness measurements for each. The urgency for identifying the common ground between these two disparate fields is high, as mechanical failure is ready to stand alongside stiffness as a functional design requirement. In comparing toughness measurement methods between hydrogels and cartilage, we recommend that the best option for evaluating mechanical failure of hydrogel-based constructs for cartilage tissue engineering may be tensile testing based on the single edge notch test, in part because specimen preparation is more straightforward and a related American Society for Testing and Materials (ASTM) standard can be adopted in a fracture mechanics context.

  14. A three-dimensional analysis of fracture mechanics test pieces of different geometries part 2 - Constraint and material variations

    Energy Technology Data Exchange (ETDEWEB)

    Tkach, Y., E-mail: Yuri.Tkach@WGIM.com [Department of Civil and Structural Engineering, School of MACE, UMIST/University of Manchester, PO Box 88, Manchester M60 1QD (United Kingdom); Burdekin, F.M., E-mail: mburdekin@aol.com [Department of Civil and Structural Engineering, School of MACE, UMIST/University of Manchester, PO Box 88, Manchester M60 1QD (United Kingdom)

    2012-05-15

    This paper reports the second stage of an extensive series of detailed three-dimensional elastic-plastic finite element analyses on the influence of fracture mechanics test specimen geometry and different material properties on constraint and triaxiality in the near crack tip region. The specimens studied were pre-cracked plain-sided and side-grooved Charpy sized specimens, plain-sided and side-grooved compact tension specimens of thickness B = 25 mm and plain-sided compact tension specimens of thickness B = 100 mm all with the ratio of the crack length to the specimen width a/W = 0.5. Stress-strain curves of materials of different yield strength and strain hardening behaviour spanning the range of practical interest for typical structural steels were implemented into the finite element models. The level of constraint in the specimens modelled has been characterised in terms of both the Q-stress parameter and the ratio of hydrostatic to the equivalent stress components. It has been established that in-plane constraint in the fracture toughness test pieces is significantly affected by the absolute ligament size of the specimen. It has also been shown that the strain hardening behaviour is one of the major material parameters defining constraint level in the fracture toughness specimen. - Highlights: Black-Right-Pointing-Pointer 3D FE analyses on plain and side-grooved Charpy sized and CT specimens of two sizes. Black-Right-Pointing-Pointer Crack tip constraint analysed for Q-stress and hydrostatic/equivalent stress ratio. Black-Right-Pointing-Pointer In-plane constraint is significantly affected by the absolute ligament size. Black-Right-Pointing-Pointer Constraint level is significantly affected by material strain hardening behaviour.

  15. A three-dimensional analysis of fracture mechanics test pieces of different geometries part 2 - Constraint and material variations

    International Nuclear Information System (INIS)

    Tkach, Y.; Burdekin, F.M.

    2012-01-01

    This paper reports the second stage of an extensive series of detailed three-dimensional elastic-plastic finite element analyses on the influence of fracture mechanics test specimen geometry and different material properties on constraint and triaxiality in the near crack tip region. The specimens studied were pre-cracked plain-sided and side-grooved Charpy sized specimens, plain-sided and side-grooved compact tension specimens of thickness B = 25 mm and plain-sided compact tension specimens of thickness B = 100 mm all with the ratio of the crack length to the specimen width a/W = 0.5. Stress–strain curves of materials of different yield strength and strain hardening behaviour spanning the range of practical interest for typical structural steels were implemented into the finite element models. The level of constraint in the specimens modelled has been characterised in terms of both the Q-stress parameter and the ratio of hydrostatic to the equivalent stress components. It has been established that in-plane constraint in the fracture toughness test pieces is significantly affected by the absolute ligament size of the specimen. It has also been shown that the strain hardening behaviour is one of the major material parameters defining constraint level in the fracture toughness specimen. - Highlights: ► 3D FE analyses on plain and side-grooved Charpy sized and CT specimens of two sizes. ► Crack tip constraint analysed for Q-stress and hydrostatic/equivalent stress ratio. ► In-plane constraint is significantly affected by the absolute ligament size. ► Constraint level is significantly affected by material strain hardening behaviour.

  16. Effects of heavy weight waste glass recycled as fine aggregate on the mechanical properties of mortar specimens

    International Nuclear Information System (INIS)

    Choi, So Yeong; Choi, Yoon Suk; Yang, Eun Ik

    2017-01-01

    Highlights: • The properties of mortar used heavy weight waste glass as fine aggregate were compared. • Unit volume weight and shielding performance increased with the content of waste glass. • However, the strength decreased as the waste glass substitution increased. • The waste glass substitution affected on pores ranging from 10–100 nm. - Abstract: The quantities of heavy weight waste glass have increased over time due to rapid industrialization and changes in the quality of life. Moreover, most of this waste is not recycled. Concrete is the most widely used construction material, the huge amounts of natural resources are required to make concrete. Therefore, it is necessary to investigate the possibility of recycling of heavy weight waste glass as an ingredient in the manufacturing of concrete. In this study, the suitability of heavy weight waste glass as a fine aggregate material is considered. The results of flow test, unit volume weight, radiation shielding performance, compressive strength, flexural strength, and micropore and macropore distribution of mortar are compared and evaluated. It was found that when the heavy weight waste glass substitution ratio increases, the fluidity, unit volume weight and radiation shielding performance also increase. However, the compressive and flexural strength of mortar gradually decrease with an increase in the substitution ratio of heavy weight waste glass. Moreover, the micro pore size distribution is significantly affected by the substitution of heavy weight waste glass.

  17. Biaxial Creep Specimen Fabrication

    International Nuclear Information System (INIS)

    JL Bump; RF Luther

    2006-01-01

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments

  18. Biaxial Creep Specimen Fabrication

    Energy Technology Data Exchange (ETDEWEB)

    JL Bump; RF Luther

    2006-02-09

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments.

  19. Study of oxide film formed in a pre cracked CT specimen of AISI 304L during a rising displacement test in 288 C water

    International Nuclear Information System (INIS)

    Diaz S, A.; Castano M, V.

    2007-01-01

    A study of oxide film formed inside pre cracked CT specimens during a rising displacement test in high temperature water (288 C) was performed in this study, The environmental conditions used during the experiments were similar to these found in Boiling Water Reactors (BWR): Normal Water Condition (NWC - 200 ppb O 2 ) and Hydrogen Water Chemistry (HWC - 125 ppb H2). The oxide films formed were analyzed by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD). In both cases the oxide film consisted of two layers identified as magnetite. In the case of HWC the results agree with previous reports that mention magnetite as a stable phase in reducing conditions. However the stable phase in oxidant conditions is hematite and this work shows the presence of magnetite crystals in the narrow crack of CT specimens in spite of the oxidant environmental condition. This situation confirms that inside the pre-cracked CT specimens the environmental conditions were different from the oxidant bulk, and probably a poor oxygen access and stagnant conditions within the narrow crack promoted a localized reducing environment that permitted the magnetite formation. Is evident that the crack growth studies should consider the conditions inside crack because they are significantly different. (Author)

  20. A novel automatic molecular test for detection of multidrug resistance tuberculosis in sputum specimen: A case control study.

    Science.gov (United States)

    Li, Qiang; Ou, Xi C; Pang, Yu; Xia, Hui; Huang, Hai R; Zhao, Bing; Wang, Sheng F; Zhao, Yan L

    2017-07-01

    MiniLab tuberculosis (ML TB) assay is a new automatic diagnostic tool for diagnosis of multidrug resistance tuberculosis (MDR-TB). This study was conducted with aims to know the performance of this assay. Sputum sample from 224 TB suspects was collected from tuberculosis suspects seeking medical care at Beijing Chest hospital. The sputum samples were directly used for smear and ML TB test. The left sputum sample was used to conduct Xpert MTB/RIF, Bactec MGIT culture and drug susceptibility test (DST). All discrepancies between the results from DST, molecular and phenotypic methods were confirmed by DNA Sequencing. The sensitivity and specificity of ML TB test for detecting MTBC from TB suspects were 95.1% and 88.9%, respectively. The sensitivity for smear negative TB suspects was 64.3%. For detection of RIF resistance, the sensitivity and specificity of ML TB test were 89.2% and 95.7%, respectively. For detection of INH resistance, the sensitivity and specificity of ML TB test were 78.3% and 98.1%, respectively. ML TB test showed similar performance to Xpert MTB/RIF for detection of MTBC and RIF resistance. In addition, ML TB also had good performance for INH resistance detection. Copyright © 2017. Published by Elsevier Ltd.

  1. Quality assurance of the reactor pressure vessel of nuclear power plants. Determination of the fracture toughness KIC above the ductile-brittle transition region on small test specimens by means of a conformal mapping

    International Nuclear Information System (INIS)

    Ullrich, G.; Krompholz, K.

    1994-01-01

    The ''surveillance-programs'' for the determination of the mechanical properties of reactor pressure vessel (RPV) materials, as a function of the neutron dose, include impact and tensile tests for the boiling water reactor; while for pressurized water reactors additional wedge opening load specimens (WOL), for the measurement of the fracture toughness K IC at low temperatures, are utilized. While the Charpy impact toughness gives the total magnitude of energy, which indicates the change of the material state, e.g. the state of embrittlement, the fracture toughness, I IC , gives a base for mechanical calculations. This is of importance for components in which cracks or flaws are assumed. The mechanical analysis, and its relevance to safety assessments, depends on the knowledge of different parameters such as geometry of the structure and flaws, and load history of the structure. Fracture mechanical methods play an important role, if the leak-before-fracture problem is considered. Within the frame work of fracture mechanical methods, only the influence of assumed macroscopic cracks on the structural behaviour can be handled. Flaw formation processes in flaw-free structures, as well as the treatment of short flaws, can not currently be included. In the regime of low and intermediate temperatures (for ferritic and austenitic materials, normally below 400 o C), the rules of linear elastic fracture mechanics (LEFM) and elasto-plastic fracture mechanics (EPFM) are applied, some of which are already part of the code cases. (author) 5 figs., 32 refs

  2. Multi-channel mechanical test machine for HANARO (I)

    International Nuclear Information System (INIS)

    Song, M. S.; Choi, Y.; Cho, M. S.; Kim, B. G.; Kang, Y. H.

    2004-01-01

    Design and fabrication of multi-channel mechanical test machine is useful and important for the study of in-pile test of nuclear materials in HANARO. The dimension and shape of the multi-channel mechanical test machine should be fixed to a test reactor and their objectives. KAERI successfully developed a non-instrumented multi-channel mechanical test machine for material irradiation tests in a domestic research reactor, HANARO. This results in strongly stimulating and accelerating irradiation tests of materials in domestic industry and research fields with HANARO. Although various types of in-pile creep capsule were made for well installation in each test reactor, there is no in-pile creep multi-channel mechanical test machine for HANARO. Hence, the objectives of this study are to fabricate and test a multi-channel mechanical test machine of HANARO

  3. A Fractual Mechanical Testing and Design Strategy for FRC Structures

    DEFF Research Database (Denmark)

    Stang, Henrik; Olesen, John Forbes

    1999-01-01

    A unified testing and design strategy for fibre reinforced concrete structures is summarised. The strategy is based on fracture mechanical concepts. Emphasis is placed on material characterisation and testing specifications.......A unified testing and design strategy for fibre reinforced concrete structures is summarised. The strategy is based on fracture mechanical concepts. Emphasis is placed on material characterisation and testing specifications....

  4. Predicition of the first spinning cylinder test using continuum damage mechanics

    International Nuclear Information System (INIS)

    Lidbury, D.P.G.; Sherry, A.H.; Bilby, B.A.; Howard, I.C.; Li, Z.H.; Eripret, C.

    1993-01-01

    For many years large-scale experiments have been performed world-wide to validate aspects of fracture mechanics methodology. Special emphasis has been given to correlations between small- and large-scale specimen behaviour in quantifying the structural behaviour of pressure vessels, piping and closures. Within this context, the first three Spinning Cylinder Tests, performed by AEA Technology at its Risley Laboratory, addressed the phenomenon of stable crack growth by ductile tearing in contained yield and conditions simulating pressurized thermal shock loading in a PWR reactor pressure vessel. A notable feature of the test data was that the effective resistance to crack growth, as measured in terms of the J R-curve, was appreciably greater than that anticipated from small-scale testing, both at initiation and after small amounts (a few millimeters) of tearing. In the present paper, two independent finite element analyses of the First Spinning Cylinder Test (SC 1) are presented and compared. Both involved application of the Rousselier ductile damage theory in an attempt to better understand the transferability of test data from small specimens to structural validation tests. In each instance, the parameters associated with the theory's constitutive equation were calibrated in terms of data from notched-tensile and (or) fracture mechanics tests, metallographic observation and (or) chemical composition. The evolution of ductile damage local to the crack tip during SC 1 was thereby calculated and, together with a crack growth criterion based on the maximization of opening-mode stress, used as the basis for predicting cylinder R-Curves (angular velocity vs. Δa, J-integral vs. Δa). The results show the Rousselier model to be capable of correctly predicting the enhancement of tearing toughness of the cylinder relative to that of conventional test specimens, given an appropriate choice of finite element cell size in the region representing the crack tip

  5. Dynamic Mechanical Testing Techniques for Cortical and Cancellous Bone

    Science.gov (United States)

    Cloete, Trevor

    2017-06-01

    Bone fracture typically occurs as an impact loading event (sporting accidents, vehicle collisions), the simulation of which requires in-depth understanding of dynamic bone behavior. Bone is a natural composite material with a complex multi length-scale hierarchical microstructure. At a macroscopic level, it is classified into hard/compact cortical bone and soft/spongy cancellous (trabecular) bone, though both are low-impedance materials relative to steels. Cortical bone is predominant in long bones, while in complex bone geometries (joints, flat bones) a cancellous bone core supports a thin cortical shell. Bone has primarily been studied at quasi-static strain rates (ɛ˙ failure, with interrupted quasi-static tests revealing a strong microstructure dependence. However, bone specimens are typically destroyed during dynamic tests, leading to a lack of dynamic microstructural damage investigations. In this paper, a short overview of dynamic bone testing is presented to give context to the challenges of testing low impedance, strain-rate dependent, non-linear, visco-elastic-brittle materials. Recent state-of-the-art experimental developments in dynamic bone testing are reviewed, with emphasis on pulse shaping, momentum trapping and ISR testing. These techniques allow for dynamic bone testing at small strains and near-constant strain rates with intact specimen recovery. The results are compared to those obtained with varying strain rate tests. Interrupted dynamic test results with microstructural analysis of the recovered specimens are presented and discussed. The paper concludes with a discussion of the experimental and modeling challenges that lie ahead in the field of dynamic bone behavior. The financial assistance of the National Research Foundation and the University of Cape Town towards this research is hereby acknowledged. Opinions expressed and conclusions arrived at are those of the author alone.

  6. Analytic and clinical performance of cobas HPV testing in anal specimens from HIV-positive men who have sex with men.

    Science.gov (United States)

    Wentzensen, Nicolas; Follansbee, Stephen; Borgonovo, Sylvia; Tokugawa, Diane; Sahasrabuddhe, Vikrant V; Chen, Jie; Lorey, Thomas S; Gage, Julia C; Fetterman, Barbara; Boyle, Sean; Sadorra, Mark; Tang, Scott Dahai; Darragh, Teresa M; Castle, Philip E

    2014-08-01

    Anal human papillomavirus (HPV) infections are common, and the incidence of anal cancer is high in HIV-infected men who have sex with men (MSM). To evaluate the performance of HPV assays in anal samples, we compared the cobas HPV test (cobas) to the Roche Linear Array HPV genotyping assay (LA) and cytology in HIV-infected MSM. Cytology and cobas and LA HPV testing were conducted for 342 subjects. We calculated agreement between the HPV assays and the clinical performance of HPV testing and HPV genotyping alone and in combination with anal cytology. We observed high agreement between cobas and LA, with cobas more likely than LA to show positive results for HPV16, HPV18, and other carcinogenic types. Specimens testing positive in cobas but not in LA were more likely to be positive for other markers of HPV-related disease compared to those testing negative in both assays, suggesting that at least some of these were true positives for HPV. cobas and LA showed high sensitivities but low specificities for the detection of anal intraepithelial neoplasia grade 2/3 (AIN2/3) in this population (100% sensitivity and 26% specificity for cobas versus 98.4% sensitivity and 28.9% specificity for LA). A combination of anal cytology and HPV genotyping provided the highest accuracy for detecting anal precancer. A higher HPV load was associated with a higher risk of AIN2/3 with HPV16 (P(trend) < 0.001), HPV18 (P(trend) = 0.07), and other carcinogenic types (P(trend) < 0.001). We demonstrate that cobas can be used for HPV detection in anal cytology specimens. Additional tests are necessary to identify men at the highest risk of anal cancer among those infected with high-risk HPV. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  7. Intensity of the Internal Standard Response as the Basis for Reporting a Test Specimen as Negative or Inconclusive

    Science.gov (United States)

    2007-08-01

    conclusive results in toxicology tests. Even under normal analytical conditions where the IS is poorly recovered, the substance may escape detection if it is...and en- zyme immunoassay of cannabis metabolites with gas chromatography/mass spectrometry analysis of 11-nor-Δ9-tetrahydrocannabinol-9- carboxylic

  8. Urine culture - catheterized specimen

    Science.gov (United States)

    Culture - urine - catheterized specimen; Urine culture - catheterization; Catheterized urine specimen culture ... urinary tract infections may be found in the culture. This is called a contaminant. You may not ...

  9. Design and fabrication of a cryostat for low temperature mechanical testing for the Mechanical and Materials Engineering group at CERN

    CERN Document Server

    Aviles Santillana, I; Gerardin, A; Guinchard, M; Langeslag, S A E; Sgobba, S

    2015-01-01

    Mechanical testing of materials at low temperatures is one of the cornerstones of the Mechanical and Materials Engineering (MME) group at CERN. A long tradition of more than 20 years and a unique know - how of such tests has been developed with an 18 kN double-walled cryostat. Large campaigns of material qualification have been carried out and the mechanical behaviour of materials at 4 K has been vastly studied in sub - size samples for projects like LEP, LHC and its experiments. With the aim of assessing the mechanical properties of materials of higher strength and/or issued from heavy gauge products for which testing standardized specimens of larger cross section might be more adapted, a new 100 kN cryostat capable of hosting different shapes of normalized samples has been carefully designed and fabricated inhouse together with the associated tooling and measurement instrumentation. It has been conceived to be able to adapt to different test frames both dynamic and static, which will be of paramount importa...

  10. Evaluation of laboratory tests for dengue diagnosis in clinical specimens from consecutive patients with suspected dengue in Belo Horizonte, Brazil.

    Science.gov (United States)

    Ferraz, Fernanda Oliveira; Bomfim, Maria Rosa Quaresma; Totola, Antônio Helvécio; Ávila, Thiago Vinícius; Cisalpino, Daniel; Pessanha, José Eduardo Marques; da Glória de Souza, Danielle; Teixeira Júnior, Antônio Lúcio; Nogueira, Maurício Lacerda; Bruna-Romero, Oscar; Teixeira, Mauro Martins

    2013-09-01

    Dengue is a widely spread arboviral disease in tropical and subtropical regions of the world. Dengue fever presents clinical characteristics similar to other febrile illness. Thus laboratory diagnosis is important for adequate management of the disease. The present study was designed to evaluate the diagnostic performance of real-time PCR and serological methods for dengue in a real epidemic context. Clinical data and blood samples were collected from consecutive patients with suspected dengue who attended a primary health care unit in Belo Horizonte, Brazil. Serologic methods and real-time PCR were performed in serum samples to confirm dengue diagnosis. Among the 181 consecutive patients enrolled in this study with suspected dengue, 146 were considered positive by serological criteria (positive NS1 ELISA and/or anti-dengue IgM ELISA) and 138 were positive by real-time PCR. Clinical criteria were not sufficient for distinguishing between dengue and non-dengue febrile illness. The PCR reaction was pre-optimized using samples from patients with known viral infection. It had similar sensitivity compared to NS1 ELISA (88% and 89%, respectively). We also evaluated three commercial lateral flow immunochromatographic tests for NS1 detection (BIOEASY, BIORAD and PANBIO). All three tests showed high sensitivity (94%, 91% and 81%, respectively) for dengue diagnosis. According to our results it can be suggested that lateral flow tests for NS1 detection are the most feasible methods for early diagnosis of dengue. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. [Identification of anaerobic gram-negative bacilli isolated from various clinical specimens and determination of antibiotic resistance profiles with E-test methods].

    Science.gov (United States)

    Demir, Cengiz; Keşli, Recep

    2018-01-01

    The aim of this study was to identify gram-negative anaerobic bacilli isolated from various clinical specimens that were obtained from patients with suspected anaerobic infections and to determine the antibiotic resistance profiles by using the antibiotic concentration gradient method. The study was performed in Afyon Kocatepe University Ahmet Necdet Sezer Research and Practice Hospital, Medical Microbiology Laboratory between 1 November 2014 and 30 October 2015. Two hundred and seventyeight clinical specimens accepted for anaerobic culture were enrolled in the study. All the samples were cultivated anaerobically by using Schaedler agar with 5% defibrinated sheep blood and Schaedler broth. The isolated anaerobic gram-negative bacilli were identified by using both the conventional methods and automated identification system (VITEK 2, bioMerieux, France). Antibiotic susceptibility tests were performed with antibiotic concentration gradient method (E-test, bioMerieux, France); against penicillin G, clindamycin, cefoxitin, metronidazole, moxifloxacin, imipenem, meropenem, ertapenem and doripenem for each isolate. Of the 28 isolated anaerobic gram-negative bacilli; 14 were identified as Bacteroides fragilis group, 9 were Prevotella spp., and 5 were Fusobacterium spp. The highest resistance rate was found against penicillin (78.5%) and resistance rates against clindamycin and cefoxitin were found as 17.8% and 21.4%, respectively. No resistance was found against metronidazole, moxifloxacin, imipenem, meropenem, ertapenem and doripenem. As a result, isolation and identification of anaerobic bacteria are difficult, time-consuming and more expensive when compared with the cost of aerobic culture. The rate of anaerobic bacteria isolation may be increased by obtaining the appropriate clinical specimen and appropriate transportation of these specimens. We believe that the data obtained from the study in our center may offer benefits for the follow up and treatment of infections

  12. Low upper-shelf toughness, high transition temperature test insert in HSST [Heavy Section Steel Technology] PTSE-2 [Pressurized Thermal Shock Experiment-2] vessel and wide plate test specimens: Final report

    International Nuclear Information System (INIS)

    Domian, H.A.

    1987-02-01

    A piece of A387, Grade 22 Class 2 (2-1/4 Cr - 1 Mo) steel plate specially heat treated to produce low upper-shelf (LUS) toughness and high transition temperature was installed in the side wall of Heavy Section Steel Technology (HHST) vessel V-8. This vessel is to be tested by the Oak Ridge National Laboratory (ORNL) in the Pressurized Thermal Shock Experiment-2 (PTSE-2) project of the HSST program. Comparable pieces of the plate were made into six wide plate specimens and other samples. These samples underwent tensile tests, Charpy tests, and J-integral tests. The results of these tests are given in this report

  13. The UKAEA mechanical test programs in air

    International Nuclear Information System (INIS)

    Wood, D.S.

    1977-01-01

    The design of CDFR will be based on the mechanical behaviour of materials in air, although at a later date account may need to be taken of sodium effects. The need for this Information is outlined in the introductory paper. The extent of the air programs and preliminary findings are described in this paper

  14. The UKAEA mechanical test programs in air

    Energy Technology Data Exchange (ETDEWEB)

    Wood, D S [UKAEA, RNPDL, Risley (United Kingdom)

    1977-07-01

    The design of CDFR will be based on the mechanical behaviour of materials in air, although at a later date account may need to be taken of sodium effects. The need for this Information is outlined in the introductory paper. The extent of the air programs and preliminary findings are described in this paper.

  15. Evaluation of chromogenic medium and direct latex agglutination test for detection of group B streptococcus in vaginal specimens from pregnant women in Lebanon and Kuwait.

    Science.gov (United States)

    Ghaddar, Nahed; Alfouzan, Wadha; Anastasiadis, Elie; Al Jiser, Tamima; Itani, Saad Eddine; Dernaika, Racha; Eid, Toufic; Ghaddar, Ali; Charafeddine, Adib; Dhar, Rita; El Hajj, Hiba

    2014-10-01

    This study was undertaken to evaluate chromogenic medium and a direct latex agglutination test (DLA) for detection of Group B Streptococcus (GBS) in the vaginal specimens of pregnant women, and to ascertain the prevalence of GBS in this population in Kuwait and Lebanon. Vaginal swabs, collected from women at 35-37 weeks of gestation, were cultured on 5 % sheep blood agar (SBA), colistin nalidixic acid agar (CNA), Strept B Select chromogenic agar (SBS) as well as Lim enrichment broth in 168 cases in Lebanon while only SBA was used for 1391 samples in Kuwait. In addition, vaginal samples from 102 GBS-positive and 20 GBS-negative women near the time of delivery were collected in Kuwait for evaluation of the DLA test. During the study period, the prevalence of GBS colonization was determined to be 20.7 % (288/1391) in Kuwait while 18.4 % (31) of 168 pregnant women in Lebanon had vaginal cultures positive for GBS. By direct plating of vaginal swabs on the three media used, the isolation rates of GBS were 51.6, 64.5 and 77.4 % on SBA, CNA and SBS, respectively, which increased to 90.35, 93.1 and 96.8 %, respectively, following subculture in Lim broth after 18 h of incubation. The sensitivity of the DLA test was found to be dependent on the density of GBS colonization, resulting in 100 % sensitivity and 100 % specificity for heavy (>10(2) c.f.u. per swab) and moderately heavy (50-100 c.f.u. per swab) growth of GBS. However, for vaginal specimens yielding women. The DLA test, in particular, could prove to be a useful tool for immediate detection of GBS in women near delivery so that intrapartum antibiotic prophylaxis can be initiated. © 2014 The Authors.

  16. Automation of the linear array HPV genotyping test and its application for routine typing of human papillomaviruses in cervical specimens of women without cytological abnormalities in Switzerland.

    Science.gov (United States)

    Dobec, Marinko; Bannwart, Fridolin; Kaeppeli, Franz; Cassinotti, Pascal

    2009-05-01

    There is a need for reliable, automated high throughput HPV detection and genotyping methods for pre- and post-prophylactic vaccine intervention analyses. To optimize the linear array (LA) HPV genotyping test (Roche Diagnostics, Rotkreuz) in regard to possible automation steps for the routine laboratory diagnosis of HPV infections and to analyze the HPV genotype distribution in cervical specimens of women without cytological abnormalities in Switzerland. 680 cervical cell specimens with normal cytology, obtained from women undergoing routine cervical screening by liquid-based Pap smear, were analyzed by the LA HPV genotyping test for HPV-DNA. The automation of the LA HPV genotyping test resulted in a total hands-on time reduction of 255 min (from 480 to 225 min; 53%). Any of 37 HPV genotypes were detected in 117 (17.2%) and high-risk (HR) HPV in 55 (8.1%) of 680 women with normal cytology. The highest prevalence of any HPV (28.1%) and HR-HPV (15.1%) was observed in age-group 21-30 and showed a continuous decrease in older age-groups. The most common HR-HPV genotypes were HPV-16 (12%), HPV-31 (9.4%), HPV-52 (6%), HPV-51 (5.1%), HPV-45 (4.3%), HPV-58 (4.3%) and HPV-59 (4.3%). The optimization and automation of the LA HPV genotyping test makes it suited for high throughput HPV detection and typing. The epidemiological data provides information about distribution of HPV genotypes in women without cytological abnormalities in Switzerland and may be important for determining the future impact of vaccines and potential changes in the country's epidemiological HPV profile.

  17. Enhancing the Accuracy of Advanced High Temperature Mechanical Testing through Thermography

    Directory of Open Access Journals (Sweden)

    Jonathan Jones

    2018-03-01

    Full Text Available This paper describes the advantages and enhanced accuracy thermography provides to high temperature mechanical testing. This technique is not only used to monitor, but also to control test specimen temperatures where the infra-red technique enables accurate non-invasive control of rapid thermal cycling for non-metallic materials. Isothermal and dynamic waveforms are employed over a 200–800 °C temperature range to pre-oxidised and coated specimens to assess the capability of the technique. This application shows thermography to be accurate to within ±2 °C of thermocouples, a standardised measurement technique. This work demonstrates the superior visibility of test temperatures previously unobtainable by conventional thermocouples or even more modern pyrometers that thermography can deliver. As a result, the speed and accuracy of thermal profiling, thermal gradient measurements and cold/hot spot identification using the technique has increased significantly to the point where temperature can now be controlled by averaging over a specified area. The increased visibility of specimen temperatures has revealed additional unknown effects such as thermocouple shadowing, preferential crack tip heating within an induction coil, and, fundamental response time of individual measurement techniques which are investigated further.

  18. A numerical study of two different specimen fixtures for the modified compact tension test – their influence on concrete fracture parameters

    Czech Academy of Sciences Publication Activity Database

    Holušová, Táňa; Seitl, Stanislav; Cifuentes, H.; Canteli, A.

    2016-01-01

    Roč. 10, č. 35 (2016), s. 242-249 ISSN 1971-8993 Institutional support: RVO:68081723 Keywords : Modified Compact Tension Test * Fracture Parameters * Cementitious Composites * FEM Subject RIV: JL - Materials Fatigue, Friction Mechanics

  19. Comparison of fracture toughness values from an IPIRG-1 large-scale pipe system test and C(T) specimens on wrought TP304 stainless steel

    International Nuclear Information System (INIS)

    Olson, R.J.; Scott, P.; Marschall, C.W.; Wilkowski, G.M.

    1994-01-01

    Within the First International Piping Integrity Research Group (IPIRG-1) program, pipe system experiments involving dynamic loading with intentionally circumferentially cracked pipe were conducted. The pipe system was fabricated from 406-mm (16-inch) diameter Schedule 100 pipe, and the experiments were conducted at a pressure of 15.5 MPa (2,250 psi) and 288 C (550 F). The loads consisted of pressure, dead-weight, thermal expansion, inertia, and dynamic anchor motion. Significant instrumentation was used to allow the material fracture resistance to be calculated from these large-scale experiments. Three independent analyses were used to calculate the toughness directly from one of these pipe experiments. A comparison of the toughness values from the stainless steel base metal pipe experiment to standard quasi-static and dynamic C(T) specimen tests showed the pipe toughness value was significantly lower than that obtained from C(T) specimens. It is hypothesized that the cyclic loading from inertial stresses in this pipe system experiment caused local degradation of the material toughness. Such effects are not considered in current LBB or pipe flaw evaluation criteria

  20. New tests of completeness of quantum mechanics

    International Nuclear Information System (INIS)

    Kupczynski, M.

    1984-12-01

    It is observed that in the theory with supplementary parameters TSP each pure quantum ensemble is mixed with respect to these parameters. New statistical purity tests of quantum ensembles are proposed. Additional arguments are given that the violation of the Bell inequalities does not necessarily mean the violation of the Einsteinian separability. (author)

  1. Present status of mechanical testing technology at the Research Hot Laboratory

    International Nuclear Information System (INIS)

    Kizaki, M.; Tobita, T.; Koya, T.; Kikuchi, T.

    1993-01-01

    Mechanical tests of irradiated metallic materials at the Research Hot Laboratory(RHL) have been carried out for 30 years to support material research in JAERI and to evaluate the irradiation integrity of pressure vessel steel in commercial power plant. Two tensile testing machines and one Charpy impact testing machine are available for the examinations. One of the tensile testing machines has 1000 kgf load capacity under the vacuum of ∼ 10 -7 torr at the temperature of 1300degC max.. The other one has 10 tonf load capacity, and is utilized for the multi-purpose tests such as tensile and compressive tests in air atmosphere at the temperature between -160 and 900degC. Examinations cover tensile test, bending test, J ic fracture toughness test, low cycle fatigue test and so on. Charpy impact testing machine with notched-bar specimen is instrumented with 30 kgf-m capacity in the temperature range of -140 - 240 degC. To support these mechanical tests in RHL, special jigs, devices and instruments have been developed. (author)

  2. Neutron interferometric tests of quantum mechanics

    International Nuclear Information System (INIS)

    Rauch, H.

    1986-01-01

    Since the invention of perfect crystal neutron interferometry this technique has become an important tool in the realization of many textbook experiments in quantum mechanics. Widely separated coherent beams of thermal neutrons are produced and superposed by dynamical Bragg diffraction from a properly shaped perfect crystal. The observed interference patterns show the characteristic coherence properties of matter waves which are influenced by the individual particle and by the properties of the experimental device. The verification of the 4π-periodicity of spinor wavefunctions and the realization of the spin-superposition experiment on a macroscopic scale has become feasible by this technique. A new kind of a quantum beat effect with an energy sensitivity of 2.7 x 20 19 eV has been observed in a double coil resonance experiment. The influence of gravity and of the Earth's rotation on the wavefunction become visible at a level of an elementary particle with non-zero mass. All the results are in agreement with the formulation of quantum mechanics but, nevertheless, they stimulate discussion about its interpretation. The particle-wave dualism becomes obvious on a macroscopic scale and with a beam of massive particles. (author)

  3. Mechanical system diagnostics using vibration testing techniques

    Science.gov (United States)

    Mcleod, Catherine D.; Raju, P. K.; Crocker, M. J.

    1990-01-01

    The 'Cepstrum' technique of vibration-path identification allows the recovery of the transfer function of a system with little knowledge as to its excitation force, by means of a mathematical manipulation of the system output in conjunction with subtraction of part of the output and suitable signal processing. An experimental program has been conducted to evaluate the usefulness of this technique in the cases of simple, cantilever-beam and free-free plate structures as well as in that of a complex mechanical system. On the basis of the transfer functions thus recovered, it was possible to evaluate the shifts in the resonance frequencies of a structure due to the presence of defects.

  4. An investigation of normal urine with a creatinine concentration under the cutoff of 20 mg/dL for specimen validity testing in a toxicology laboratory.

    Science.gov (United States)

    Holden, Brad; Guice, Erica A

    2014-05-01

    In clinical and forensic toxicology laboratories, one commonly used method for urine specimen validity testing is creatinine concentration. In this study, workplace guidelines are examined to determine their relevance to forensic and clinical toxicology samples. Specifically, it investigates the occurrence of urine creatinine concentrations under 20 mg/dL and notes potential issues with factors influencing creatinine concentration by utilizing a simple, novel method consisting of cation-paring high-pressure liquid chromatography in tandem with ultraviolet detection to determine the creatinine concentration in 3019 donors. Of the 4227 sample population in this study, 209 (4.94%) were below the cutoff value of 20 mg/dL for dilute urine. Because there are many factors that can influence the urinary creatinine concentration, samples that have creatinine under the 20 mg/dL cutoff do not always implicate sample adulteration. © 2014 American Academy of Forensic Sciences.

  5. Thermo-mechanical cementation effects in bentonite investigated by unconfined compression tests

    International Nuclear Information System (INIS)

    Dueck, Ann

    2010-01-01

    Results from the project LOT showed that specimens exposed to warm conditions had a significantly reduced strain at failure compared to reference material. The objective of the present study was to investigate the impact of parameters such as temperature, density, water content and degree of saturation on the occurrence of brittleness at failure of bentonite specimens. To quantify the influence of the different parameters the unconfined compression test was used on specimens with a height and diameter of 20 mm. In this test the relation between stress and strain is determined from axial compression of a cylindrical specimen. Brittle failure is in this investigation mainly seen on specimens having a density of ρ ≥ 2,060 kg/m 3 or on specimens exposed to high temperature T ≥ 150 deg C in the laboratory. Brittle failure behaviour was also seen on unsaturated specimens with a degree of saturation less than Sr i = 0% before saturation, on specimens with a final degree of saturation of S r ≤ 97% and also on one specimen subjected to consolidation during preparation. Brittle failure and reduced strain were noticed in the heated field exposed material in the LOT project. Similar behaviour was also observed in the present short term laboratory tests. However, the specimens in the present study showing this behaviour had higher density, lower degree of saturation or were exposed to higher temperatures than the field exposed specimens

  6. Judgments of Risk Frequencies: Tests of Possible Cognitive Mechanisms

    Science.gov (United States)

    Hertwig, Ralph; Pachur, Thorsten; Kurzenhauser, Stephanie

    2005-01-01

    How do people judge which of 2 risks claims more lives per year? The authors specified 4 candidate mechanisms and tested them against people's judgments in 3 risk environments. Two mechanisms, availability by recall and regressed frequency, conformed best to people's choices. The same mechanisms also accounted well for the mapping accuracy of…

  7. In-cell facility for performing mechanical-property tests on irradiated cladding

    International Nuclear Information System (INIS)

    Yaggee, F.L.; Haglund, R.C.; Mattas, R.F.

    1978-11-01

    A new facility was developed for testing cladding sections of LWR fuel rods. This facility and the accompanying test procedures have improved the level of in-cell mechanical-testing capabilities, making them comparable to existing capabilities for unirradiated cladding. The new facility is currently being used to study the susceptibility of irradiated Zircaloy cladding from LWR fuel rods to iodine stress-corrosion cracking. Preliminary testing results indicate a systematic effect of temperature, stress and irradiation on the susceptibility of annealed and stress-relieved Zircaloy-2. Experimental data obtained to date are being used to develop a stress-corrosion cracking model for LWR fuel rod failure. SEM examination of the undisturbed fracture surface of specimens that failed by pinhole leakage provides useful information on crack propagation and morphology

  8. Development of an evaluation method for fracture mechanical tests on small samples based on a cohesive zone model; Entwicklung einer Auswertemethode fuer bruchmechanische Versuche an kleinen Proben auf der Basis eines Kohaesivzonenmodells

    Energy Technology Data Exchange (ETDEWEB)

    Mahler, Michael

    2016-07-01

    The safety and reliability of nuclear power plants of the fourth generation is an important issue. It is based on a reliable interpretation of the components for which, among other fracture mechanical material properties are required. The existing irradiation in the power plants significantly affects the material properties which therefore need to be determined on irradiated material. Often only small amounts of irradiated material are available for characterization. In that case it is not possible to manufacture sufficiently large specimens, which are necessary for fracture mechanical testing in agreement with the standard. Small specimens must be used. From this follows the idea of this study, in which the fracture toughness can be predicted with the developed method based on tests of small specimens. For this purpose, the fracture process including the crack growth is described with a continuum mechanical approach using the finite element method and the cohesive zone model. The experiments on small specimens are used for parameter identification of the cohesive zone model. The two parameters of the cohesive zone model are determined by tensile tests on notched specimens (cohesive stress) and by parameter fitting to the fracture behavior of smalls specimens (cohesive energy). To account the different triaxialities of the specimens, the cohesive stress is used depending on the triaxiality. After parameter identification a large specimen can be simulated with the cohesive zone parameters derived from small specimens. The predicted fracture toughness of this big specimen fulfills the size requirements in the standard (ASTM E1820 or ASTM E399) in contrast to the small specimen. This method can be used for ductile and brittle material behavior and was validated in this work. In summary, this method offers the possibility to determine the fracture toughness indirectly based on small specimen testing. Main advantage is the low required specimen volume. Thereby massively

  9. Dynamic Brazilian Test for Mechanical Characterization of Ceramic Ballistic Protection

    Directory of Open Access Journals (Sweden)

    Martina Scapin

    2017-01-01

    Full Text Available The aim of this work is to identify the tensile strength of alumina (Corbit98, by performing Brazilian tests at different loading rate. In this kind of test, generally used for brittle material in static loading conditions, a cylindrical specimen is diametrically compressed and failure is generated in the middle of the component as a consequence of a positive tensile stress. In this work, this experimental technique was applied also in dynamic loading conditions by using a setup based on the Split Hopkinson Pressure Bar. Due to the properties of the investigated material, among which are high hardness, high compressive strength, and brittle behaviour, some precautions were needed to assure the validity of the tests. Digital Image Correlation techniques were applied for the analysis of high framerate videos.

  10. Some mechanical properties of small specimens cut from 1.79-inch-thick southern pine dried for 6 hours at 300°F or for 5 days at 180°F- A Comparison

    Science.gov (United States)

    P. Koch; W.L. Wellford

    1978-01-01

    Small specimens cut from 1.79-inch-thick southern pine dried from green condition for 6 hours at a dry-bulb temperature of 300 F suffered no diminution in the mechanical properties determined, when compared to matched wood dried for 5 days at 180 F.

  11. Screen-film specimen radiography

    International Nuclear Information System (INIS)

    Shepard, S.J.; Hogan, J.; Schreck, B.

    1990-01-01

    This paper reports on the reproducibility and quality of biopsy specimen radiographs, a unique phototimed cabinet x-ray system is being developed. The system utilizes specially modified Kodal Min-R cassettes and will be compatible with current mammographic films. Tube voltages are in the 14-20-kVp range with 0.1-1.0-second exposure times. A top-hat type compression device is used (1) to compress the specimen to uniform thickness, (2) to measure the specimen thickness and determine optimum kVp, and (3) to superimpose a grid over the specimen for identification of objects of radiographic interest. The phototiming circuit developed specifically for this purpose will be described along with the modified Min-R cassette. Characteristics of the generator and cabinet will also be described. Tests will be performed on phantoms to evaluate the system limitations

  12. TESTING METHODS FOR MECHANICALLY IMPROVED SOILS: RELIABILITY AND VALIDITY

    Directory of Open Access Journals (Sweden)

    Ana Petkovšek

    2017-10-01

    Full Text Available A possibility of in-situ mechanical improvement for reducing the liquefaction potential of silty sands was investigated by using three different techniques: Vibratory Roller Compaction, Rapid Impact Compaction (RIC and Soil Mixing. Material properties at all test sites were investigated before and after improvement with the laboratory and the in situ tests (CPT, SDMT, DPSH B, static and dynamic load plate test, geohydraulic tests. Correlation between the results obtained by different test methods gave inconclusive answers.

  13. Results of charpy V-notch impact testing of structural steel specimens irradiated at ∼30 degrees C to 1 x 1016 neutrons/cm2 in a commercial reactor cavity

    International Nuclear Information System (INIS)

    Iskander, S.K.; Stoller, R.E.

    1997-04-01

    A capsule containing Charpy V-notch (CVN) and mini-tensile specimens was irradiated at ∼ 30 degrees C (∼ 85 degrees F) in the cavity of a commercial nuclear power plant to a fluence of 1 x 10 16 neutrons/cm 2 (> 1MeV). The capsule included six CVN impact specimens of archival High Flux Isotope Reactor A212 grade B ferritic steel and five CVN impact specimens of a well-studied A36 structural steel. This irradiation was part of the ongoing study of neutron-induced damage effects at the low temperature and flux experienced by reactor supports. The plant operators shut down the plant before the planned exposure was reached. The exposure of these specimens produced no significant irradiation-induced embrittlement. Of interest were the data on unirradiated specimens in the L-T orientation machined from a single plate of A36 structural steel, which is the same specification for the structural steel used in some reactor supports. The average CVN energy of five unirradiated specimens obtained from one region of the plate and tested at room temperature was ∼ 99 J, while the energy of 11 unirradiated specimens from other locations of the same plate was 45 J, a difference of ∼ 220%. The CVN impact energies for all 18 specimens ranged from a low of 32 J to a high of 111 J. Moreover, it appears that the University of Kansas CVN impact energy data of the unirradiated specimens at the 100-J level are shifted toward higher temperatures by about 20 K. The results were an example of the extent of scatter possible in CVN impact testing. Generic values for the CVN impact energy of A36 should be used with caution in critical applications

  14. Bandwidth Analysis of Functional Interconnects Used as Test Access Mechanism

    NARCIS (Netherlands)

    Van den Berg, A.; Ren, P.; Marinissen, E.J.; Gaydadjiev, G.; Goossens, K.

    2010-01-01

    Test data travels through a System on Chip (SOC) from the chip pins to the Core-Under-Test (CUT) and vice versa via a Test Access Mechanism (TAM). Conventionally, a TAM is implemented using dedicated communication infrastructure. However, also existing functional interconnect, such as a bus or

  15. Bandwidth analysis of functional interconnects used as test access mechanism

    NARCIS (Netherlands)

    Berg, van den Ardy; Ren, P.; Marinissen, Erik Jan; Gaydadjiev, G.N.; Goossens, K.G.W.

    2010-01-01

    Test data travels through a System on Chip (SOC) from the chip pins to the Core-Under-Test (CUT) and vice versa via a Test Access Mechanism (TAM). Conventionally, a TAM is implemented using dedicated communication infrastructure. However, also existing functional interconnect, such as a bus or

  16. Comparative study of fracture mechanical test methods for concrete

    DEFF Research Database (Denmark)

    Østergaard, Lennart; Olesen, John Forbes

    2004-01-01

    and the interpretation, i.e. the analysis needed to extract the stress-crack opening relationship, the fracture energy etc. Experiments are carried out with each test configuration using mature, high performance concrete. The results show that the UTT is a highly complicated test, which only under very well controlled...... circumstances will yield the true fracture mechanical properties. It is also shown that both the three point bending test and the WST are well-suited substitutes for the uniaxial tension test.......This paper describes and compares three different fracture mechanical test methods; the uniaxial tension test (UTT), the three point bending test (TPBT) and the wedge splitting test (WST). Potentials and problems with the test methods will be described with regard to the experiment...

  17. Thermo-mechanical cementation effects in bentonite investigated by unconfined compression tests

    Energy Technology Data Exchange (ETDEWEB)

    Dueck, Ann (Clay Technology AB, Lund (Sweden))

    2010-01-15

    Results from the project LOT showed that specimens exposed to warm conditions had a significantly reduced strain at failure compared to reference material. The objective of the present study was to investigate the impact of parameters such as temperature, density, water content and degree of saturation on the occurrence of brittleness at failure of bentonite specimens. To quantify the influence of the different parameters the unconfined compression test was used on specimens with a height and diameter of 20 mm. In this test the relation between stress and strain is determined from axial compression of a cylindrical specimen. Brittle failure is in this investigation mainly seen on specimens having a density of rho >= 2,060 kg/m3 or on specimens exposed to high temperature T >= 150 deg C in the laboratory. Brittle failure behaviour was also seen on unsaturated specimens with a degree of saturation less than Sr < 90%. Failure at reduced strain was seen in this investigation on specimens exposed to T = 150 deg C, on specimens having a water content of w{sub i} = 0% before saturation, on specimens with a final degree of saturation of S{sub r} <= 97% and also on one specimen subjected to consolidation during preparation. Brittle failure and reduced strain were noticed in the heated field exposed material in the LOT project. Similar behaviour was also observed in the present short term laboratory tests. However, the specimens in the present study showing this behaviour had higher density, lower degree of saturation or were exposed to higher temperatures than the field exposed specimens

  18. Analysis of stress intensity factors for a new mechanical corrosion specimen; Analyse du facteur d`intensite de contrainte pour une nouvelle eprouvette de mecanique corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Rassineux, B; Crouzet, D; Le Hong, S

    1996-03-01

    Electricite de France is conducting a research program to determine corrosion cracking rates in the steam generators Alloy 600 tubes of the primary system. The objective is to correlate the cracking rates with the specimen stress intensity factor K{sub I}. One of the samples selected for the purpose of this study is the longitudinal notched specimen TEL (TEL: ``Tubulaire a Entailles Longitudinales``). This paper presents the analysis of the stress intensity factor and its experimental validation. The stress intensity factor has been evaluated for different loads using 3D finite element calculations with the Hellen-Parks and G({theta}) methods. Both crack initiation and propagation are considered. As an assessment of the method, the numerical simulations are in good agreement with the fatigue crack growth rates measured experimentally for TEL and compact tension (CT) specimens. (authors). 8 refs., 6 figs., 2 tabs.

  19. Evaluation of mechanical properties of Dy123 bulk superconductors by 3-point bending tests

    International Nuclear Information System (INIS)

    Katagiri, K.; Hatakeyama, Y.; Sato, T.; Kasaba, K.; Shoji, Y.; Murakami, A.; Teshima, H.; Hirano, H.

    2006-01-01

    In order to evaluate the mechanical properties, such as Young's modulus and strength, of Dy123 bulk superconductors and those with 10 wt.% Ag 2 O, we performed 3-point bending tests at room (RT) and liquid nitrogen temperatures (LNT) using specimens cut from the bulks. The Young's modulus and the bending strength increased with decrease in temperature. In the tests loading in the direction of c-axis and ones perpendicular to it, Young's moduli were almost comparable at both RT and LNT. Although the strengths for both orientations were also comparable at LNT, those at RT were different. Young's moduli loaded in the direction of c-axis for Ag 2 O added bulk specimens, 127 GPa in average at RT, were almost comparable to those without Ag 2 O, and 134 GPa at LNT, were slightly lower than those without Ag 2 O. On the other hand, the strengths at both RT and LNT were enhanced by 20% by the Ag addition. The mechanical properties of Dy123 bulks without Ag 2 O were compared with those of Y123 bulks obtained previously. The Young's modulus for loading in the direction of c-axis was slightly lower, and the strength was comparable to those in Y123 bulks, respectively

  20. Nondestructive mechanical characterization of developing biological tissues using inflation testing.

    Science.gov (United States)

    Oomen, P J A; van Kelle, M A J; Oomens, C W J; Bouten, C V C; Loerakker, S

    2017-10-01

    One of the hallmarks of biological soft tissues is their capacity to grow and remodel in response to changes in their environment. Although it is well-accepted that these processes occur at least partly to maintain a mechanical homeostasis, it remains unclear which mechanical constituent(s) determine(s) mechanical homeostasis. In the current study a nondestructive mechanical test and a two-step inverse analysis method were developed and validated to nondestructively estimate the mechanical properties of biological tissue during tissue culture. Nondestructive mechanical testing was achieved by performing an inflation test on tissues that were cultured inside a bioreactor, while the tissue displacement and thickness were nondestructively measured using ultrasound. The material parameters were estimated by an inverse finite element scheme, which was preceded by an analytical estimation step to rapidly obtain an initial estimate that already approximated the final solution. The efficiency and accuracy of the two-step inverse method was demonstrated on virtual experiments of several material types with known parameters. PDMS samples were used to demonstrate the method's feasibility, where it was shown that the proposed method yielded similar results to tensile testing. Finally, the method was applied to estimate the material properties of tissue-engineered constructs. Via this method, the evolution of mechanical properties during tissue growth and remodeling can now be monitored in a well-controlled system. The outcomes can be used to determine various mechanical constituents and to assess their contribution to mechanical homeostasis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Mechanical Fatigue Testing of High-Burnup Fuel for Transportation Applications

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jy-An John [ORNL; Wang, Hong [ORNL

    2015-05-01

    This report describes testing designed to determine the ability of high burnup (HBU) (>45 GWd/MTU) spent fuel to maintain its integrity under normal conditions of transportation. An innovative system, Cyclic Integrated Reversible-bending Fatigue Tester (CIRFT), has been developed at Oak Ridge National Laboratory (ORNL) to test and evaluate the mechanical behavior of spent nuclear fuel (SNF) under conditions relevant to storage and transportation. The CIRFT system is composed of a U-frame equipped with load cells for imposing the pure bending loads on the SNF rod test specimen and measuring the in-situ curvature of the fuel rod during bending using a set up with three linear variable differential transformers (LVDTs).

  2. External quality assessment in the voluntary counseling and testing centers in the Brazilian Amazon using dried tube specimens: results of an effectiveness evaluation

    Directory of Open Access Journals (Sweden)

    Andréa Mônica Brandão Beber

    2015-06-01

    Full Text Available INTRODUCTION : In 2011, the Brazilian Ministry of Health rolled out a program for the external quality assessment of rapid human immunodeficiency virus (HIV tests using the dried tube specimen (DTS method (EQA-RT/DTS-HIV. Our objective was to evaluate the implementation of this program at 71 voluntary counseling and testing centers (VCTCs in the Brazilian Legal Amazonian area one year after its introduction. METHODS : Quantitative and qualitative study that analyzed secondary data and interviews with healthcare workers (HCWs (n=39 and VCTC coordinators (n=32 were performed. The assessment used 18 key indicators to evaluate the three dimensions of the program's logical framework: structure, process, and result. Each indicator was scored from 1-4, and the aggregate results corresponding to the dimensions were expressed as proportions. The results were compared to the perceptions of the HCWs and coordinators regarding the EQA-RT/DTS-HIV program. RESULTS: The aggregate scores for the three dimensions of structure, process, and result were 91.7%, 78.6%, and 95%, respectively. The lowest score in each dimension corresponded to a different indicator: access to Quali-TR online system 39% (structure, registration in Quali-TR online system 38.7% (process, and VCTC completed the full process in the program's first round 63.4% (result. Approximately 36% of the HCWs and 52% of the coordinators reported enhanced trust in the program for its rapid HIV testing performance. CONCLUSIONS: All three program dimensions exhibited satisfactory results (>75%. Nevertheless, the study findings highlight the need to improve certain program components. Additionally, long-term follow-ups is needed to provide a more thorough picture of the process for external quality assessment.

  3. Simulation of strain-hardening in ECC uniaxial test specimen by use of a damage mechanics formulation

    DEFF Research Database (Denmark)

    Dick-Nielsen, Lars; Stang, Henrik; Poulsen, Peter Noe

    2006-01-01

    scale it is shown that the cohesive law for a unidirectional fiber reinforced cementitious composite can be found through superposition of the cohesive law for mortar and the fiber bridging curve. On the meso scale I it is shown that the maximum crack opening observed during crack propagation in ECC...

  4. Testing and Modeling of Mechanical Characteristics of Resistance Welding Machines

    DEFF Research Database (Denmark)

    Wu, Pei; Zhang, Wenqi; Bay, Niels

    2003-01-01

    for both upper and lower electrode systems. This has laid a foundation for modeling the welding process and selecting the welding parameters considering the machine factors. The method is straightforward and easy to be applied in industry since the whole procedure is based on tests with no requirements......The dynamic mechanical response of resistance welding machine is very important to the weld quality in resistance welding especially in projection welding when collapse or deformation of work piece occurs. It is mainly governed by the mechanical parameters of machine. In this paper, a mathematical...... model for characterizing the dynamic mechanical responses of machine and a special test set-up called breaking test set-up are developed. Based on the model and the test results, the mechanical parameters of machine are determined, including the equivalent mass, damping coefficient, and stiffness...

  5. Multiple Irradiation Capsule Experiment (MICE)-3B Irradiation Test of Space Fuel Specimens in the Advanced Test Reactor (ATR) - Close Out Documentation for Naval Reactors (NR) Information

    Energy Technology Data Exchange (ETDEWEB)

    M. Chen; CM Regan; D. Noe

    2006-01-09

    Few data exist for UO{sub 2} or UN within the notional design space for the Prometheus-1 reactor (low fission rate, high temperature, long duration). As such, basic testing is required to validate predictions (and in some cases determine) performance aspects of these fuels. Therefore, the MICE-3B test of UO{sub 2} pellets was designed to provide data on gas release, unrestrained swelling, and restrained swelling at the upper range of fission rates expected for a space reactor. These data would be compared with model predictions and used to determine adequacy of a space reactor design basis relative to fission gas release and swelling of UO{sub 2} fuel and to assess potential pellet-clad interactions. A primary goal of an irradiation test for UN fuel was to assess performance issues currently associated with this fuel type such as gas release, swelling and transient performance. Information learned from this effort may have enabled use of UN fuel for future applications.

  6. Cytology specimens offer an effective alternative to formalin-fixed tissue as demonstrated by novel automated detection for ALK break-apart FISH testing and immunohistochemistry in lung adenocarcinoma.

    Science.gov (United States)

    Rosenblum, Frida; Hutchinson, Lloyd M; Garver, Joann; Woda, Bruce; Cosar, Ediz; Kurian, Elizabeth M

    2014-11-01

    Minimally invasive sampling by cytology or core needle biopsy often provides an initial diagnosis for treatment in patients with lung nodules. From these limited specimens, multiple molecular studies are frequently requested. Current guidelines from the US Food and Drug Administration recommend using formalin-fixed paraffin-embedded tissue sections for the detection of anaplastic lymphoma kinase (ALK) gene rearrangement by fluorescence in situ hybridization (FISH). The authors compared alcohol-fixed and formalin-fixed cytology specimens using a novel automated detection for ALK rearrangements by FISH and immunohistochemistry (IHC). ALK FISH testing was performed on 129 lung adenocarcinomas from 71 cytology cases and 58 biopsy/resection specimens using Papanicolaou staining with integrated cytomorphology. IHC with the ALK D5F3 antibody was performed on cases with residual material (88 of 129 cases). The mean age of the patients was 66 years; there were 62 women and 67 men. ALK gene rearrangement was present in 4% of cytology specimens (3 of 71 specimens) and 7% of surgical specimens (4 of 58 specimens). FISH in 13 cases was technically unsuccessful. Of the 7 FISH-positive cases, only 2 cytology cases (4%) and 2 surgical cases (6%) were found to be positive with the ALK antibody, demonstrating 80% concordance. The one case found to be negative for ALK by IHC demonstrated a variant rearrangement of the ALK 2p23 gene locus by FISH. The results of the current study validate the usefulness of alcohol-fixed and/or formalin-fixed cytology specimens for ALK rearrangement by a novel automated FISH method. IHC using the D5F3 antibody for ALK is specific in this limited cohort. The authors also demonstrated that alcohol-fixed cytology specimens can be used for ALK rearrangement by automated FISH, alone or in conjunction with IHC. © 2014 American Cancer Society.

  7. Development of small scale mechanical testing techniques on ion beam irradiated 304 SS

    International Nuclear Information System (INIS)

    Reichardt, A.; Abad, M.D.; Hosemann, P.; Lupinacci, A.; Kacher, J.; Minor, A.; Jiao, Z; Chou, P.

    2015-01-01

    Austenitic stainless steels are widely used for structural components in light water reactors, however uncertainty in their susceptibility to irradiation assisted stress corrosion cracking (IASCC) has made long term performance predictions difficult. In addition, the testing of reactor irradiated materials has proven challenging due to the long irradiation times required, limited sample availability, and unwanted activation. To address these problems, we apply recently developed techniques in nano-indentation and micro-compression testing to small volume samples of 10 dpa proton-beam irradiated 304 stainless steel. Cross sectional nano-indentation was performed on both proton beam irradiated and non-irradiated samples at temperatures ranging from 22 to 300 C. degrees to determine the effects of irradiation and operating temperature on hardening. Micro-compression tests using 2 μm x 2 μm x 5 μm focused-ion beam milled pillars were then performed in situ in an electron microscope to allow for a more accurate look at stress-strain behavior along with real-time observations of localized mechanical deformation. Large sudden slip events and significant increase in yield strength are observed in irradiated micro-compression samples at room temperature. Elevated temperature nano-indentation results reveal the possibility of thermally-activated changes in deformation mechanism for irradiated specimens. Since the deformation mechanism information provided by micro-compression testing can provide valuable information about IASCC susceptibility, future work will involve ex situ micro-compression tests at reactor operating temperature

  8. Electrothermal Action of the Pulse of the Current of a Short Artificial-Lightning Stroke on Test Specimens of Wires and Cables of Electric Power Objects

    Science.gov (United States)

    Baranov, M. I.; Rudakov, S. V.

    2018-03-01

    The authors have given results of investigations of the electrothermal action of aperiodic pulses of temporal shape 10/350 μs of the current of a short artificial-lightning stroke on test specimens of electric wires and cables with copper and aluminum cores and sheaths with polyvinylchloride and polyethylene insulations of power circuits of industrial electric power objects. It has been shown that the thermal stability of such wires and cables is determined by the action integral of the indicated current pulse. The authors have found the maximum permissible and critical densities of this pulse in copper and aluminum current-carrying parts of the wires and cables. High-current experiments conducted under high-voltage laboratory conditions on a unique generator of 10/350 μs pulses of an artificial-lightning current with amplitude-time parameters normalized according to the existing requirements of international and national standards and with tolerances on them have confirmed the reliability of the proposed calculated estimate for thermal lightning resistance of cabling and wiring products.

  9. Electrothermal Action of the Pulse of the Current of a Short Artificial-Lightning Stroke on Test Specimens of Wires and Cables of Electric Power Objects

    Science.gov (United States)

    Baranov, M. I.; Rudakov, S. V.

    2018-05-01

    The authors have given results of investigations of the electrothermal action of aperiodic pulses of temporal shape 10/350 μs of the current of a short artificial-lightning stroke on test specimens of electric wires and cables with copper and aluminum cores and sheaths with polyvinylchloride and polyethylene insulations of power circuits of industrial electric power objects. It has been shown that the thermal stability of such wires and cables is determined by the action integral of the indicated current pulse. The authors have found the maximum permissible and critical densities of this pulse in copper and aluminum current-carrying parts of the wires and cables. High-current experiments conducted under high-voltage laboratory conditions on a unique generator of 10/350 μs pulses of an artificial-lightning current with amplitude-time parameters normalized according to the existing requirements of international and national standards and with tolerances on them have confirmed the reliability of the proposed calculated estimate for thermal lightning resistance of cabling and wiring products.

  10. AGC-2 Specimen Post Irradiation Data Package Report

    Energy Technology Data Exchange (ETDEWEB)

    Windes, William Enoch [Idaho National Lab. (INL), Idaho Falls, ID (United States); Swank, W. David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rohrbaugh, David T. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Cottle, David L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-08-01

    This report documents results of the post-irradiation examination material property testing of the creep, control, and piggyback specimens from the irradiation creep capsule Advanced Graphite Creep (AGC)-2 are reported. This is the second of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-2 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 600°C and to a peak dose of 5 dpa (displacements per atom). One-half of the creep specimens were subjected to mechanical stresses (an applied stress of either 13.8, 17.2, or 20.7 MPa) to induce irradiation creep. All post-irradiation testing and measurement results are reported with the exception of the irradiation mechanical strength testing, which is the last destructive testing stage of the irradiation testing program. Material property tests were conducted on specimens from 15 nuclear graphite grades using a similar loading configuration as the first AGC capsule (AGC-1) to provide easy comparison between the two capsules. However, AGC-2 contained an increased number of specimens (i.e., 487 total specimens irradiated) and replaced specimens of the minor grade 2020 with the newer grade 2114. The data reported include specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and volume data necessary to derive density, elastic constants (Young’s modulus, shear modulus, and Poisson’s ratio) from ultrasonic time-of-flight velocity measurements, Young’s modulus from the fundamental frequency of vibration, electrical resistivity, and thermal diffusivity and thermal expansion data from 100–500°C. No data outliers were determined after all measurements were completed. A brief statistical analysis was performed on the irradiated data and a limited comparison between

  11. Chromogenic culture media or rapid immunochromatographic test: Which is better for detecting Klebsiella pneumoniae that produce OXA-48 and can they be used in blood and urine specimens.

    Science.gov (United States)

    Genc, Ozlem; Aksu, Evrim

    2018-05-01

    Our goal was to compare a rapid test (OXA-48K-SeT) and four different chromogenic media (CHROMagar KPC, CHROMagar mSuperCARBA, ChromID Carba and ChromID OXA-48) for the detection of OXA-48 producing Klebsiella pneumoniae isolates and spiked urine/blood samples with these bacteria. In total 100 K.pneumoniae isolates, including 60 OXA-48 positive, 15 other carbapenemase producing, 15 Extended spectrum betalactamases (ESBL) positive and 10 carbapenem sensitive K.pneumoniae were included in the study. After all samples were inoculated into all chromogenic media, temocillin discs were placed onto the media. OXA-48K-SeT was studied according to the manufacturer's instructions and the lower detection limit was determined. Sensitivities and specificities of all chromogenic media and rapid test were detected as 100%. All of the OXA-48 producers were found resistant to temocillin on all chromogenic media. The lower detection limit of the rapid assay was determined as 10 6 in both direct bacterial samples and in spiked urine/blood samples. As a result, four chromogenic culture media and OXA-48 K-SeT can be used safely for detection of OXA-48 positive K.pneumoniae isolates. Although direct clinical specimens were not used, our study suggests that this media and OXA-48 K-SeT may be used in patient samples like blood and urine. Further studies are needed to assess this suggestion. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Shaking table qualification tests of mechanical and electrical components

    International Nuclear Information System (INIS)

    Jurukovski, D.

    1993-01-01

    This presentation covers the experience of the Institute of Earthquake Engineering and Engineering Seismology, Skopje, Republic of Macedonia in seismic qualification of mechanical components by shaking table testing. The characteristics of the biaxial seismic and single component shaking tables used at the Institute are given. Some examples of the experience from performed test for reactor components are included

  13. Analysis of a proposed crucial test of quantum mechanics

    International Nuclear Information System (INIS)

    Collett, M.J.; Loudon, R.

    1987-01-01

    An experiment based on an extension of the Einstein-Podolsky-Rosen argument has been proposed by Popper as a crucial test of the Copenhagen interpretation of quantum mechanics. Here the authors show, by a slightly more complete version of Popper's analysis, although still at a relatively primitive level of sophistication, that the proposed experiment does not in fact provide such a test. (author)

  14. Out-of pile mechanical test: simulating reactivity initiated accident (RIA) of zircaloy-4 cladding tube

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Myung Ho; Kim, Jun Hwan; Choi, Byoung Kwon; Jeong, Young Hwan [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2004-07-01

    The ejection or drop of a control rod in a reactivity initiated accident (RIA) causes a sudden increase in reactor power and in turn deposits a large amount of energy into the fuel. In a RIA, cladding tubes bear thermal expansion due to sudden reactivity and may fail from the resulting mechanical damage. Thus, RIA can be one of the safety margin reducers because the oxide on the tubes makes their thickness to support the load less as well as hydrides from the corrosion reduce the ductility of the tubes. In a RIA, the peak of reactor power from reactivity change is about 0.1m second and the temperature of the cladding tubes increases up to 1000 .deg. C in several seconds. Although it is hard to fully simulate the situation, several attempts to measure the change of mechanical properties under a RIA situation has done using a reduction coil, ring tension tests with high speed. This research was done to see the effect of oxide on the change of circumferential strength and ductility of Zircaloy-4 tubes in a RIA. The ring stretch tensile tests were performed with the strain rate of 1/sec and 0.01/s to simulate a transient of the cladding tube under a RIA. Since the test results of the ring tensile test are very sensitive to the lubricant, the tests were also carried out to select a suitable lubricant before the test of oxided specimens.

  15. Mechanical Characterization and Corrosion Testing of X608 Al Alloy

    Energy Technology Data Exchange (ETDEWEB)

    Prabhakaran, Ramprashad; Choi, Jung-Pyung; Stephens, Elizabeth V.; Catalini, David; Lavender, Curt A.; Rohatgi, Aashish

    2016-02-07

    This paper describes the mechanical characterization and corrosion testing of X608 Al alloy that is being considered for A-pillar covers for heavy-duty truck applications. Recently, PNNL developed a thermo-mechanical process to stamp A-pillar covers at room temperature using this alloy, and the full-size prototype was successfully stamped by a tier-1 supplier. This study was conducted to obtain additional important information related to the newly developed forming process, and to further improve its mechanical properties. The solutionization temperature, pre-strain and paint-bake heat-treatment were found to influence the alloy’s fabricability and mechanical properties. Natural aging effect on the formability was investigated by limiting dome height (LDH) tests. Preliminary corrosion experiments showed that the employed thermo-mechanical treatments did not significantly affect the corrosion behavior of Al X608.

  16. Mechanical Testing of Polymeric Composites for Aircraft Applications: Standards, Requirements and Limitations

    Science.gov (United States)

    Chinchan, Levon; Shevtsov, Sergey; Soloviev, Arcady; Shevtsova, Varvara; Huang, Jiun-Ping

    The high-loaded parts of modern aircrafts and helicopters are often produced from polymeric composite materials. Such materials consist of reinforcing fibers, packed by layers with the different angles, and resin, which uniformly distributes the structural stresses between fibers. These composites should have an orthotropic symmetry of mechanical properties to obtain the desirable spatial distribution of elastic moduli consistent to the external loading pattern. Main requirements to the aircraft composite materials are the specified elastic properties (9 for orthotropic composite), long-term strength parameters, high resistance against the environmental influences, low thermal expansion to maintain the shape stability. These properties are ensured by an exact implementation of technological conditions and many testing procedures performed with the fibers, resin, prepregs and ready components. Most important mechanical testing procedures are defined by ASTM, SACMA and other standards. However in each case the wide diversity of components (dimensions and lay-up of fibers, rheological properties of thermosetting resins) requires a specific approach to the sample preparation, testing, and numerical processing of the testing results to obtain the veritable values of tested parameters. We pay the special attention to the cases where the tested specimens are cut not from the plates recommended by standards, but from the ready part manufactured with the specific lay-up, tension forces on the reinforcing fiber at the filament winding, and curing schedule. These tests can provide most useful information both for the composite structural design and to estimate a quality of the ready parts. We consider an influence of relation between specimen dimensions and pattern of the fibers winding (or lay-up) on the results of mechanical testing for determination of longitudinal, transverse and in-plane shear moduli, an original numerical scheme for reconstruction of in-plane shear

  17. Sierra/SolidMechanics 4.48 Verification Tests Manual.

    Energy Technology Data Exchange (ETDEWEB)

    Plews, Julia A.; Crane, Nathan K; de Frias, Gabriel Jose; Le, San; Littlewood, David John; Merewether, Mark Thomas; Mosby, Matthew David; Pierson, Kendall H.; Porter, Vicki L.; Shelton, Timothy; Thomas, Jesse David; Tupek, Michael R.; Veilleux, Michael; Xavier, Patrick G.

    2018-03-01

    Presented in this document is a small portion of the tests that exist in the Sierra / SolidMechanics (Sierra / SM) verification test suite. Most of these tests are run nightly with the Sierra / SM code suite, and the results of the test are checked versus the correct analytical result. For each of the tests presented in this document, the test setup, a description of the analytic solution, and comparison of the Sierra / SM code results to the analytic solution is provided. Mesh convergence is also checked on a nightly basis for several of these tests. This document can be used to confirm that a given code capability is verified or referenced as a compilation of example problems. Additional example problems are provided in the Sierra / SM Example Problems Manual. Note, many other verification tests exist in the Sierra / SM test suite, but have not yet been included in this manual.

  18. Chromogenic In Situ Hybridization and p16/Ki67 Dual Staining on Formalin-Fixed Paraffin-Embedded Cervical Specimens: Correlation with HPV-DNA Test, E6/E7 mRNA Test, and Potential Clinical Applications

    Directory of Open Access Journals (Sweden)

    Roberta Zappacosta

    2013-01-01

    Full Text Available Although HPV-DNA test and E6/E7 mRNA analyses remain the current standard for the confirmation of human papillomavirus (HPV infections in cytological specimens, no universally adopted techniques exist for the detection of HPV in formalin-fixed paraffin-embedded samples. Particularly, in routine laboratories, molecular assays are still time-consuming and would require a high level of expertise. In this study, we investigated the possible use of a novel HPV tyramide-based chromogenic in situ hybridization (CISH technology to locate HPV on tissue specimens. Then, we evaluate the potential usefulness of p16INK4a/Ki-67 double stain on histological samples, to identify cervical cells expressing HPV E6/E7 oncogenes. In our series, CISH showed a clear signal in 95.2% of the specimens and reached a sensitivity of 86.5%. CISH positivity always matched with HPV-DNA positivity, while 100% of cases with punctated signal joined with cervical intraepithelial neoplasia grade 2 or worse (CIN2+. p16/Ki67 immunohistochemistry gave an interpretable result in 100% of the cases. The use of dual stain significantly increased the agreement between pathologists, which reached 100%. Concordance between dual stain and E6/E7 mRNA test was 89%. In our series, both CISH and p16INK4a/Ki67 dual stain demonstrated high grade of performances. In particular, CISH would help to distinguish episomal from integrated HPV, in order to allow conclusions regarding the prognosis of the lesion, while p16INK4a/Ki67 dual stain approach would confer a high level of standardization to the diagnostic procedure.

  19. Chromogenic In Situ Hybridization and p16/Ki67 Dual Staining on Formalin-Fixed Paraffin-Embedded Cervical Specimens: Correlation with HPV-DNA Test, E6/E7 mRNA Test, and Potential Clinical Applications

    Science.gov (United States)

    Zappacosta, Roberta; Colasante, Antonella; Viola, Patrizia; D'Antuono, Tommaso; Lattanzio, Giuseppe; Capanna, Serena; Gatta, Daniela Maria Pia; Rosini, Sandra

    2013-01-01

    Although HPV-DNA test and E6/E7 mRNA analyses remain the current standard for the confirmation of human papillomavirus (HPV) infections in cytological specimens, no universally adopted techniques exist for the detection of HPV in formalin-fixed paraffin-embedded samples. Particularly, in routine laboratories, molecular assays are still time-consuming and would require a high level of expertise. In this study, we investigated the possible use of a novel HPV tyramide-based chromogenic in situ hybridization (CISH) technology to locate HPV on tissue specimens. Then, we evaluate the potential usefulness of p16INK4a/Ki-67 double stain on histological samples, to identify cervical cells expressing HPV E6/E7 oncogenes. In our series, CISH showed a clear signal in 95.2% of the specimens and reached a sensitivity of 86.5%. CISH positivity always matched with HPV-DNA positivity, while 100% of cases with punctated signal joined with cervical intraepithelial neoplasia grade 2 or worse (CIN2+). p16/Ki67 immunohistochemistry gave an interpretable result in 100% of the cases. The use of dual stain significantly increased the agreement between pathologists, which reached 100%. Concordance between dual stain and E6/E7 mRNA test was 89%. In our series, both CISH and p16INK4a/Ki67 dual stain demonstrated high grade of performances. In particular, CISH would help to distinguish episomal from integrated HPV, in order to allow conclusions regarding the prognosis of the lesion, while p16INK4a/Ki67 dual stain approach would confer a high level of standardization to the diagnostic procedure. PMID:24369532

  20. [Ex Vivo Testing of Mechanical Properties of Canine Metacarpal/Metatarsal Bones after Simulated Implant Removal].

    Science.gov (United States)

    Srnec, R; Fedorová, P; Pěnčík, J; Vojtová, L; Sedlinská, M; Nečas, A

    2016-01-01

    PURPOSE OF THE STUDY In a long-term perspective, it is better to remove implants after fracture healing. However, subsequent full or excessive loading of an extremity may result in refracture, and the bone with holes after screw removal may present a site with predilection for this. The aim of the study was to find ways of how to decrease risk factors for refracture in such a case. This involved support to the mechanical properties of a bone during its remodelling until defects following implant removal are repaired, using a material tolerated by bone tissue and easy to apply. It also included an assessment of the mechanical properties of a bone after filling the holes in it with a newly developed biodegradable polymer-composite gel ("bone paste"). The composite also has a prospect of being used to repair bony defects produced by pathological processes. MATERIAL AND METHODS Experiments were carried out on intact weight-bearing small bones in dogs. A total of 27 specimens of metacarpal/metatarsal bones were used for ex vivo testing. They were divided into three groups: K1 (n = 9) control undamaged bones; K2 (n = 9) control bones with iatrogenic damage simulating holes left after cortical screw removal; EXP (n = 9) experimental specimens in which simulated holes in bone were filled with the biodegradable self-hardening composite. The bone specimens were subjected to three-point bending in the caudocranial direction by a force acting parallel to the direction of drilling in their middiaphyses. The value of maximum load achieved (N) and the corresponding value of a vertical displacement (mm) were recorded in each specimen, then compared and statistically evaluated. RESULTS On application of a maximum load (N), all bone specimens broke in the mid-part of their diaphyses. In group K1 the average maximum force of 595.6 ± 79.5 N was needed to break the bone; in group K2 it was 347.6 ± 58.6 N; and in group EXP it was 458.3 ± 102.7 N. The groups with damaged bones, K2 and

  1. Acoustic emission from zirconium alloys during mechanical and fracture testing

    International Nuclear Information System (INIS)

    Coleman, C.E.

    1986-10-01

    The application of acoustic emission during the mechanical and fracture testing of zirconium alloys is reviewed. Acoustic emission is successful in following delayed hydride cracking quantitatively. It is especially useful when great sensitivity is required. Application to fatigue, tensile deformation and stress corrosion cracking appears promising but requires more work to separate phenomena before it can be used quantitatively. This report is based on an invited review for the American Society of Non-Destructive Testing Handbook: Volume 5, Acoustic Emission Testing

  2. Polarization tests of one-particle-exchange mechanisms

    International Nuclear Information System (INIS)

    Goldstein, G.R.; Moravcsik, M.J.

    1984-01-01

    Since one-particle-exchange (OPE) mechanisms are predominant in all aspects of elementary-particle dynamics, a novel class of polarization tests is proposed for such mechanisms. They test whether a single particle of total angular momentum J is exchanged (''J constraints'') and whether the process can be factorized into two vertices (''factorization constraints''), but the tests are independent of more detailed dynamical features such as the exact nature of the coupling at the vertices. Except for a restricted type of processes containing some low spin values, the constraints reduce the number of reaction amplitudes and offer tests of OPE which are independent of the value of J. The tests have a particularly simple form in a ''magic'' formalism in which the quantization directions of the particles are in the reaction plane and are rotated from the helicity directions by a ''magic'' angle which can be easily specified for a given s and t. The tests consist of measuring whether a certain polarization quantity vanishes or not, thus providing sensitive ''null experiments'' for the exploration of particle dynamics. The results are illustrated on the popular reaction (1/2)+(1/2)→(1/2)+(1/2), which is embodied, for example, in elastic nucleon-nucleon scattering. The tests can be used either for one single-exchange mechanism or for a combination of such mechanisms (even if they involve different J exchanges), as long as they all have the same type of parity

  3. Georeferencing Animal Specimen Datasets

    NARCIS (Netherlands)

    van Erp, M.G.J.; Hensel, R.; Ceolin, D.; van der Meij, M.

    2014-01-01

    For biodiversity research, the field of study that is concerned with the richness of species of our planet, it is of the utmost importance that the location of an animal specimen find is known with high precision. Due to specimens often having been collected over the course of many years, their

  4. Qualification tests for PWR control element drive mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Yong; Jin, Choon Eon; Choi Suhn [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-01-01

    It is necessary to perform the qualification test for the magnetic jack type CEDM to show the design compatibility because the CEDM is composed of many mechanical and electrical components complicatedly. ABB-CE performed various qualification tests during the development of the System80 CEDM to which Korea Standard Nuclear Plant (KSNP) CEDM referred. The qualification test for the CEDM is classified into the performance test and the dynamic test. The performance test is to verify operability of the CEDM, and the dynamic test is to find dynamic characteristics and to verify the structural integrity if the CEDM for the seismic accidents. Described in this report are the test requirements, the test facilities and the test methods for the performance and the dynamic qualification tests of the PWR magnetic jack type CEDM. The impacts of the design changes in the Korea Next Generation Reactor (KNGR) on the KSNP CEDM were analyzed to present the necessity for the tests. This report also proposes the facilities to perform the tests in KAERI including reasonable schedule for the tests. Attached to this report is the summary of qualification tests of System 80 CEDM performed by ABB-CE. 20 figs., 16 tabs., 21 refs. (Author) .new.

  5. Qualification tests for PWR control element drive mechanism

    International Nuclear Information System (INIS)

    Kim, In Yong; Jin, Choon Eon; Choi Suhn

    1996-01-01

    It is necessary to perform the qualification test for the magnetic jack type CEDM to show the design compatibility because the CEDM is composed of many mechanical and electrical components complicatedly. ABB-CE performed various qualification tests during the development of the System80 CEDM to which Korea Standard Nuclear Plant (KSNP) CEDM referred. The qualification test for the CEDM is classified into the performance test and the dynamic test. The performance test is to verify operability of the CEDM, and the dynamic test is to find dynamic characteristics and to verify the structural integrity if the CEDM for the seismic accidents. Described in this report are the test requirements, the test facilities and the test methods for the performance and the dynamic qualification tests of the PWR magnetic jack type CEDM. The impacts of the design changes in the Korea Next Generation Reactor (KNGR) on the KSNP CEDM were analyzed to present the necessity for the tests. This report also proposes the facilities to perform the tests in KAERI including reasonable schedule for the tests. Attached to this report is the summary of qualification tests of System 80 CEDM performed by ABB-CE. 20 figs., 16 tabs., 21 refs. (Author) .new

  6. Experimental and Numerical Investigations on Feasibility and Validity of Prismatic Rock Specimen in SHPB

    Directory of Open Access Journals (Sweden)

    Xibing Li

    2016-01-01

    Full Text Available The paper presents experimental and numerical studies on the feasibility and validity of using prismatic rock specimens in split Hopkinson pressure bar (SHPB test. Firstly, the experimental tests are conducted to evaluate the stress and strain uniformity in the prismatic specimens during impact loading. The stress analysis at the ends of the specimen shows that stress equilibrium can be achieved after about three wave reflections in the specimen, and the balance can be well maintained for a certain time after peak stress. The strain analysis reveals that the prismatic specimen deforms uniformly during the dynamic loading period. Secondly, numerical simulation is performed to further verify the stress and strain uniformity in the prismatic specimen in SHPB test. It indicates that the stress equilibrium can be achieved in prismatic specimen despite a certain degree of stress concentration at the corners. The comparative experiments demonstrate that the change of specimen shape has no significant effect on dynamic responses and failure patterns of the specimen. Finally, a dynamic crack propagation test is presented to show the application of the present work in studying fracturing mechanisms under dynamic loading.

  7. Mechanical Tests Plan after Neutron Irradiation for SMART SG Tube Materials in a Hot Cell

    International Nuclear Information System (INIS)

    Ahn, Sang Bok; Baik, Seung Jai; Kim, Do Sik; Yoo, Byung Ok; Jung, Yang Hong; Song, Woong Sub; Choo, Kee Nam; Park, Jin Seok; Lee, Yong Sun; Ryu, Woo Seog

    2010-01-01

    An advanced integral PWR, SMART (System- Integrated Modular Advanced ReacTor) is being developed in KAERI. It has compact size and a relatively small power rating compared to a conventional reactor. The main components such as the steam generators, main circulation pumps are located in the reactor vessel. Therefore they are damaged from neutron irradiations generated from nuclear fuel fissions during operation. The SMART SG tubes which are 17 mm in a diameter and 2.5 mm in a thickness will be made of Alloy 690. To ensure the operation safety the post irradiation examinations is necessary to evaluate the deterioration levels of various original properties. Specially the amount of mechanical properties change should be reflected and revised to design data. For that tensile, fracture, hardness test are planned and under preparations. In this paper the detailed plans are reviewed. Three kinds of materials having different heat treatment procedures are prepared to fabricate specimens. The capsules installed the specimens are going to be irradiated in HANARO. Finally the tests for them will be performed in IMEF, Irradiated Materials Examination Facility at KAERI

  8. Demonstration of Laser Cutting System for Tube Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Kim, G. S.; Heo, G. S.; Baik, S. J.; Kim, H. M.; Ahn, S. B. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated fuel cladding and components interrupted the applying the electric current during the processing. However, it was found that the mechanical testing data of the irradiated specimens with removal of oxide layer was less reliable than the specimens with oxide layer . The laser cutting system using Nd:YAG with fiber optic beam delivery has great potential in material processing applications of the irradiated fuel cladding and components due to non-contact process. Thus, the oxide layer doesn't interrupt the fabrication process during the laser cutting system. In the present study, the laser cutting system was designed to fabricate the mechanical testing specimens from the unirradiated fuel cladding with and without oxide. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of unirradiated specimens. The effect of surface oxide layer was also investigated for machining process of the zirlo fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer. Based on the feasibility studies and demonstration, the design of the laser cutting machine for fully or partially automatic and remotely operable system will be proposed and made.

  9. Mechanical testing of adherence of stacked layers in tubular geometry

    Energy Technology Data Exchange (ETDEWEB)

    Correia, L.A.; Schuring, E.W.; Van Delft, Y.C. [ECN Energy Efficiency in the Industry, Petten (Netherlands)

    2007-09-15

    For the development of new molecular separation technologies strong robust tubular membrane systems are required. The fragile membranes, however, need a strong defect free support such as a porous asymmetric ceramic tube. Mechanical failure of these ceramic membrane systems during manufacturing and operation is mainly caused by delamination of the stacked layers. Therefore development is focused on improving the adherence. As no standard mechanical test for tubular samples is available yet, a new tensile test was developed to facilitate the current research. The most important components in the new equipment is a test tool with a curvature matching that of the test sample and a sample casing that align and guide the test tool during the tensile test. With this tensile test the manufacturing procedure for the ECN standard tubular {alpha}-alumina support was optimized. Firing the asymmetric support at 1300C resulted in the highest mechanical strength for the support system with cohesive fracture in the support tube. With the test developed the process condition could be identified where the material of the support tube is the weakest link in the support system.

  10. Cyclic mechanical behavior of 316L: Uniaxial LCF and strain-controlled ratcheting tests

    International Nuclear Information System (INIS)

    Facheris, G.; Janssens, K.G.F.

    2013-01-01

    Highlights: ► Characterization of cyclic plastic deformation behavior of plate and tubular 316L. ► Strain-controlled ratcheting response between room temperature and 200 °C. ► Isotropic cyclic hardening is dependent on the yield criterion used. ► Ratcheting induced hardening mostly affects the kinematic hardening component. ► Ratcheting induced hardening is related to the mean strain and the ratcheting rate. -- Abstract: With the purpose of analyzing the fatigue behavior under loading conditions relevant for the primary cooling circuit of a light water nuclear reactor, a set of uniaxial low cycle fatigue and strain-controlled ratcheting tests (also named ‘cyclic tension tests’) has been performed at room temperature and at 200 °C on specimens manufactured from two different batches of stainless steel grade 316L. The experiments have been repeated varying strain amplitude, cyclic ratcheting rate and ratcheting direction in order to investigate the influence on the cyclic deformation behavior. In strain-controlled ratcheting tests, the stress response is found to be a superposition of two hardening mechanisms: the first one due to the zero mean strain cycling and the second one linked with the monotonic drifting of mean plastic strain. An approach is proposed to distinguish the effect of each mechanism and the influence of the test parameters on the hardening mechanisms is discussed

  11. Fast Flux Test Facility sodium pump operating experience - mechanical

    International Nuclear Information System (INIS)

    Buonamici, R.

    1987-11-01

    The Heat Transport System (HTS) pumps were designed, fabricated, tested, and installed in the Fast Flux Test Facility (FFTF) Plant during the period from September 1970 through July 1977. Since completion of the installation and sodium fill in December 1978, the FFTF Plant pumps have undergone extensive testing and operation with HTS testing and reactor operation. Steady-state hydraulic and mechanical performances have been and are excellent. In all, FFTF primary and secondary pumps have operated in sodium for approximately 75,000 hours and 79,000 hours, respectively, to August 24, 1987

  12. Control rod drive mechanism stator loss of coolant test

    International Nuclear Information System (INIS)

    Besel, L.; Ibatuan, R.

    1977-04-01

    This report documents the stator loss of coolant test conducted at HEDL on the lead unit Control Rod Drive Mechanism (CRDM) in February, 1977. The purpose of the test was to demonstrate scram capability of the CRDM with an uncooled stator and to obtain a time versus temperature curve of an uncooled stator under power. Brief descriptions of the test, hardware used, and results obtained are presented in the report. The test demonstrated that the CRDM could be successfully scrammed with no anomalies in both the two-phase and three-phase stator winding hold conditions after the respective equilibrium stator temperatures had been obtained with no stator coolant

  13. Space Mechanisms Lessons Learned and Accelerated Testing Studies

    Science.gov (United States)

    Fusaro, Robert L.

    1997-01-01

    A number of mechanism (mechanical moving component) failures and anomalies have recently occurred on satellites. In addition, more demanding operating and life requirements have caused mechanism failures or anomalies to occur even before some satellites were launched (e.g., during the qualification testing of GOES-NEXT, CERES, and the Space Station Freedom Beta Joint Gimbal). For these reasons, it is imperative to determine which mechanisms worked in the past and which have failed so that the best selection of mechanically moving components can be made for future satellites. It is also important to know where the problem areas are so that timely decisions can be made on the initiation of research to develop future needed technology. To chronicle the life and performance characteristics of mechanisms operating in a space environment, a Space Mechanisms Lessons Learned Study was conducted. The work was conducted by the NASA Lewis Research Center and by Mechanical Technologies Inc. (MTI) under contract NAS3-27086. The expectation of the study was to capture and retrieve information relating to the life and performance of mechanisms operating in the space environment to determine what components had operated successfully and what components had produced anomalies.

  14. Testing of the BipiColombo Antenna Pointing Mechanism

    Science.gov (United States)

    Campo, Pablo; Barrio, Aingeru; Martin, Fernando

    2015-09-01

    BepiColombo is an ESA mission to Mercury, its planetary orbiter (MPO) has two antenna pointing mechanism, High gain antenna (HGA) pointing mechanism steers and points a large reflector which is integrated at system level by TAS-I Rome. Medium gain antenna (MGA) APM points a 1.5 m boom with a horn antenna. Both radiating elements are exposed to sun fluxes as high as 10 solar constants without protections.A previous paper [1] described the design and development process to solve the challenges of performing in harsh environment.. Current paper is focused on the testing process of the qualification units. Testing performance of antenna pointing mechanism in its specific environmental conditions has required special set-up and techniques. The process has provided valuable feedback on the design and the testing methods which have been included in the PFM design and tests.Some of the technologies and components were developed on dedicated items priort to EQM, but once integrated, test behaviour had relevant differences.Some of the major concerns for the APM testing are:- Create during the thermal vacuum testing the qualification temperature map with gradients along the APM. From of 200oC to 70oC.- Test in that conditions the radio frequency and pointing performances adding also high RF power to check the power handling and self-heating of the rotary joint.- Test in life up to 12000 equivalent APM revolutions, that is 14.3 million motor revolutions in different thermal conditions.- Measure low thermal distortion of the mechanical chain, being at the same time insulated from external environment and interfaces (55 arcsec pointing error)- Perform deployment of large items guaranteeing during the process low humidity, below 5% to protect dry lubrication- Verify stability with representative inertia of large boom or reflector 20 Kgm2.

  15. Development of Reconstitution Technology for Surveillance Specimens

    International Nuclear Information System (INIS)

    Yasushi Atago; Shunichi Hatano; Eiichiro Otsuka

    2002-01-01

    The Japan Power Engineering and Inspection Corporation (JAPEIC) has been carrying out the project titled 'Nuclear Power Plant Integrated Management Technology (PLIM)' consigned by Japanese Ministry of Economy, Trade and Industry (METI) since 1996FY as a 10-years project. As one of the project themes, development of reconstitution technology for reactor pressure vessel (RPV/RV) surveillance specimens, which are installed in RPVs to monitor the neutron irradiation embrittlement on RPV/RV materials, is now on being carried out to deal with the long-term operation of nuclear power plants. The target of this theme is to establish the technical standard for applicability of reconstituted surveillance specimens including the reconstitution of the Charpy specimens and Compact Tension (CT) specimens. With the Charpy specimen reconstitution, application of 10 mm length inserts is used, which enables the conversion of tests from the LT-direction to the TL-direction. This paper presents the basic data from Charpy and CT specimens of RPV materials using the surveillance specimens obtained for un-irradiated materials including the following. 1) Reconstitution Technology of Charpy Specimens. a) The interaction between plastic zone and Heat Affected Zone (HAZ). b) The effects of the possible deviations from the standard specimens for the reconstituted specimens. 2) Reconstitution Technology of CT specimens. a) The correlation between fracture toughness and plastic zone width. Because the project is now in progress, this paper describes the outline of the results obtained as of the end of 2000 FY. (authors)

  16. Finite element simulations of two rock mechanics tests

    International Nuclear Information System (INIS)

    Dahlke, H.J.; Lott, S.A.

    1986-04-01

    Rock mechanics tests are performed to determine in situ stress conditions and material properties of an underground rock mass. To design stable underground facilities for the permanent storage of high-level nuclear waste, determination of these properties and conditions is a necessary first step. However, before a test and its associated equipment can be designed, the engineer needs to know the range of expected values to be measured by the instruments. Sensitivity studies by means of finite element simulations are employed in this preliminary design phase to evaluate the pertinent parameters and their effects on the proposed measurements. The simulations, of two typical rock mechanics tests, the plate bearing test and the flat-jack test, by means of the finite element analysis, are described. The plate bearing test is used to determine the rock mass deformation modulus. The flat-jack test is used to determine the in situ stress conditions of the host rock. For the plate bearing test, two finite element models are used to simulate the classic problem of a load on an elastic half space and the actual problem of a plate bearing test in an underground tunnel of circular cross section. For the flat-jack simulation, a single finite element model is used to simulate both horizontal and vertical slots. Results will be compared to closed-form solutions available in the literature

  17. Results of the Abbott RealTime HIV-1 assay for specimens yielding "target not detected" results by the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test.

    Science.gov (United States)

    Babady, N Esther; Germer, Jeffrey J; Yao, Joseph D C

    2010-03-01

    No significantly discordant results were observed between the Abbott RealTime HIV-1 assay and the COBAS AmpliPrep/COBAS TaqMan HIV-1 Test (CTM) among 1,190 unique clinical plasma specimens obtained from laboratories located in 40 states representing all nine U.S. geographic regions and previously yielding "target not detected" results by CTM.

  18. In vitro validation of a novel mechanical model for testing the anchorage capacity of pedicle screws using physiological load application.

    Science.gov (United States)

    Liebsch, Christian; Zimmermann, Julia; Graf, Nicolas; Schilling, Christoph; Wilke, Hans-Joachim; Kienle, Annette

    2018-01-01

    Biomechanical in vitro tests analysing screw loosening often include high standard deviations caused by high variabilities in bone mineral density and pedicle geometry, whereas standardized mechanical models made of PU foam often do not integrate anatomical or physiological boundary conditions. The purpose of this study was to develop a most realistic mechanical model for the standardized and reproducible testing of pedicle screws regarding the resistance against screw loosening and the holding force as well as to validate this model by in vitro experiments. The novel mechanical testing model represents all anatomical structures of a human vertebra and is consisting of PU foam to simulate cancellous bone, as well as a novel pedicle model made of short carbon fibre filled epoxy. Six monoaxial cannulated pedicle screws (Ø6.5 × 45mm) were tested using the mechanical testing model as well as human vertebra specimens by applying complex physiological cyclic loading (shear, tension, and bending; 5Hz testing frequency; sinusoidal pulsating forces) in a dynamic materials testing machine with stepwise increasing load after each 50.000 cycles (100.0N shear force + 20.0N per step, 51.0N tension force + 10.2N per step, 4.2Nm bending moment + 0.8Nm per step) until screw loosening was detected. The pedicle screw head was fixed on a firmly clamped rod while the load was applied in the vertebral body. For the in vitro experiments, six human lumbar vertebrae (L1-3, BMD 75.4 ± 4.0mg/cc HA, pedicle width 9.8 ± 0.6mm) were tested after implanting pedicle screws under X-ray control. Relative motions of pedicle screw, specimen fixture, and rod fixture were detected using an optical motion tracking system. Translational motions of the mechanical testing model experiments in the point of load introduction (0.9-2.2mm at 240N shear force) were reproducible within the variation range of the in vitro experiments (0.6-3.5mm at 240N shear force). Screw loosening occurred continuously in

  19. Use of precracked Charpy and smaller specimens to establish the master curve

    International Nuclear Information System (INIS)

    Sokolov, M.A.; McCabe, D.E.; Nanstad, R.K.; Davidov, Y.A.

    1997-01-01

    The current provisions used in the U.S. Code of Federal Regulations for the determination of the fracture toughness of reactor pressure vessel steels employs an assumption that there is a direct correlation between K Ic lower-bound toughness and the Charpy V-notch transition curve. Such correlations are subject to scatter from both approaches which weakens the reliability of fracture mechanics-based analyses. In this study, precracked Charpy and smaller size specimens are used in three-point static bend testing to develop fracture mechanics based K k values. The testing is performed under carefully controlled conditions such that the values can be used to predict the fracture toughness performance of large specimens. The concept of a universal transition curve (master curve) is applied. Data scatter that is characteristic of commercial grade steels and their weldments is handled by Weibull statistical modeling. The master curve is developed to describe the median K Jc fracture toughness for 1T size compact specimens. Size effects are modeled using weakest-link theory and are studied for different specimen geometries. It is shown that precracked Charpy specimens when tested within their confined validity limits follow the weakest-link size-adjustment trend and predict the fracture toughness of larger specimens. Specimens of smaller than Charpy sizes (5 mm thick) exhibit some disparities in results relative to weakest-link size adjustment prediction suggesting that application of such adjustment to very small specimens may have some limitations

  20. Testing of mechanical ventilators and infant incubators in healthcare institutions.

    Science.gov (United States)

    Badnjevic, Almir; Gurbeta, Lejla; Jimenez, Elvira Ruiz; Iadanza, Ernesto

    2017-01-01

    The medical device industry has grown rapidly and incessantly over the past century. The sophistication and complexity of the designed instrumentation is nowadays rising and, with it, has also increased the need to develop some better, more effective and efficient maintenance processes, as part of the safety and performance requirements. This paper presents the results of performance tests conducted on 50 mechanical ventilators and 50 infant incubators used in various public healthcare institutions. Testing was conducted in accordance to safety and performance requirements stated in relevant international standards, directives and legal metrology policies. Testing of output parameters for mechanical ventilators was performed in 4 measuring points while testing of output parameters for infant incubators was performed in 7 measuring points for each infant incubator. As performance criteria, relative error of output parameters for mechanical ventilators and absolute error of output parameters for infant incubators was calculated. The ranges of permissible error, for both groups of devices, are regulated by the Rules on Metrological and Technical Requirements published in the Official Gazette of Bosnia and Herzegovina No. 75/14, which are defined based on international recommendations, standards and guidelines. All ventilators and incubators were tested by etalons calibrated in an ISO 17025 accredited laboratory, which provides compliance to international standards for all measured parameters.The results show that 30% of the tested medical devices are not operating properly and should be serviced, recalibrated and/or removed from daily application.

  1. Accelerated Testing of Polymeric Composites Using the Dynamic Mechanical Analyzer

    Science.gov (United States)

    Abdel-Magid, Becky M.; Gates, Thomas S.

    2000-01-01

    Creep properties of IM7/K3B composite material were obtained using three accelerated test methods at elevated temperatures. Results of flexural creep tests using the dynamic mechanical analyzer (DMA) were compared with results of conventional tensile and compression creep tests. The procedures of the three test methods are described and the results are presented. Despite minor differences in the time shift factor of the creep compliance curves, the DMA results compared favorably with the results from the tensile and compressive creep tests. Some insight is given into establishing correlations between creep compliance in flexure and creep compliance in tension and compression. It is shown that with careful consideration of the limitations of flexure creep, a viable and reliable accelerated test procedure can be developed using the DMA to obtain the viscoelastic properties of composites in extreme environments.

  2. Nonlinear finite element analysis of a test on the mechanical mechanism of the half-steel-concrete composite beam in HTR-PM

    International Nuclear Information System (INIS)

    Sun Feng; Pan Rong

    2014-01-01

    According to a large-span half-steel-concrete (HSC) composited beam in the composited roof in the HTR-PM, a 1:3 scale specimen is investigated by the static load test. By analyzing the loading, deflection, strain and fracture development of the specimen in the process, studying the mechanical characteristics and failure pattern of such components. The ANSYS finite element software is utilized in this paper to analyze the nonlinearity behavior of the HSC beam specimen, and through comparing the experimental results and the numerical simulation, it can be illustrated that the finite element model can simulate the HSC beam accurately. From the test results, it can be concluded that by means of appropriate shear connection and anchorage length, steel plate and concrete can work together very well and the HSC beam has good load carrying capacity and ductility. These conclusions can serve as a preliminary design reference for the large span half-steel-concrete composite beam in NPP. (author)

  3. Project Physics Tests 3, The Triumph of Mechanics.

    Science.gov (United States)

    Harvard Univ., Cambridge, MA. Harvard Project Physics.

    Test items relating to Project Physics Unit 3 are presented in this booklet. Included are 70 multiple-choice and 20 problem-and-essay questions. Concepts of mechanics are examined on energy, momentum, kinetic theory of gases, pulse analyses, "heat death," water waves, power, conservation laws, normal distribution, thermodynamic laws, and…

  4. The Performance test of Mechanical Sodium Pump with Water Environment

    International Nuclear Information System (INIS)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Jeong, Ji-Young; Kim, Jong-Bum; Ko, Bock Seong; Park, Sang Jun; Lee, Yoon Sang

    2015-01-01

    As contrasted with PWR(Pressurized light Water Reactor) using water as a coolant, sodium is used as a coolant in SFR because of its low melting temperature, high thermal conductivity, the high boiling temperature allowing the reactors to operate at ambient pressure, and low neutron absorption cross section which is required to achieve a high neutron flux. But, sodium is violently reactive with water or oxygen like the other alkali metal. So Very strict requirements are demanded to design and fabricate of sodium experimental facilities. Furthermore, performance testing in high temperature sodium environments is more expensive and time consuming and need an extra precautions because operating and maintaining of sodium experimental facilities are very difficult. The present paper describes performance test results of mechanical sodium pump with water which has been performed with some design changes using water test facility in SAM JIN Industrial Co. To compare the hydraulic characteristic of model pump with water and sodium, the performance test of model pump were performed using vender's experimental facility for mechanical sodium pump. To accommodate non-uniform thermal expansion and to secure the operability and the safety, the gap size of some parts of original model pump was modified. Performance tests of modified mechanical sodium pump with water were successfully performed. Water is therefore often selected as a surrogate test fluid because it is not only cheap, easily available and easy to handle but also its important hydraulic properties (density and kinematic viscosity) are very similar to that of the sodium. Normal practice to thoroughly test a design or component before applied or installed in reactor is important to ensure the safety and operability in the sodium-cooled fast reactor (SFR). So, in order to estimate the hydraulic behavior of the PHTS pump of DSFR (600 MWe Demonstraion SFR), the performance tests of the model pump such as performance

  5. Mechanisms Engineering Test Loop - Phase 1 Status Report

    Energy Technology Data Exchange (ETDEWEB)

    Kultgen, D. [Argonne National Lab. (ANL), Argonne, IL (United States); Grandy, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Hvasta, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Lisowski, D. [Argonne National Lab. (ANL), Argonne, IL (United States); Toter, W. [Argonne National Lab. (ANL), Argonne, IL (United States); Borowski, A. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-09-01

    This report documents the current status of the Mechanisms Engineering Test Loop (METL) as of the end of FY2016. Currently, METL is in Phase I of its design and construction. Once operational, the METL facility will test small to intermediate-scale components and systems in order to develop advanced liquid metal technologies. Testing different components in METL is essential for the future of advanced fast reactors as it will provide invaluable performance data and reduce the risk of failures during plant operation.

  6. Item response theory analysis of the mechanics baseline test

    Science.gov (United States)

    Cardamone, Caroline N.; Abbott, Jonathan E.; Rayyan, Saif; Seaton, Daniel T.; Pawl, Andrew; Pritchard, David E.

    2012-02-01

    Item response theory is useful in both the development and evaluation of assessments and in computing standardized measures of student performance. In item response theory, individual parameters (difficulty, discrimination) for each item or question are fit by item response models. These parameters provide a means for evaluating a test and offer a better measure of student skill than a raw test score, because each skill calculation considers not only the number of questions answered correctly, but the individual properties of all questions answered. Here, we present the results from an analysis of the Mechanics Baseline Test given at MIT during 2005-2010. Using the item parameters, we identify questions on the Mechanics Baseline Test that are not effective in discriminating between MIT students of different abilities. We show that a limited subset of the highest quality questions on the Mechanics Baseline Test returns accurate measures of student skill. We compare student skills as determined by item response theory to the more traditional measurement of the raw score and show that a comparable measure of learning gain can be computed.

  7. An Adaptive Test Sheet Generation Mechanism Using Genetic Algorithm

    Directory of Open Access Journals (Sweden)

    Huan-Yu Lin

    2012-01-01

    Full Text Available For test-sheet composition systems, it is important to adaptively compose test sheets with diverse conceptual scopes, discrimination and difficulty degrees to meet various assessment requirements during real learning situations. Computation time and item exposure rate also influence performance and item bank security. Therefore, this study proposes an Adaptive Test Sheet Generation (ATSG mechanism, where a Candidate Item Selection Strategy adaptively determines candidate test items and conceptual granularities according to desired conceptual scopes, and an Aggregate Objective Function applies Genetic Algorithm (GA to figure out the approximate solution of mixed integer programming problem for the test-sheet composition. Experimental results show that the ATSG mechanism can efficiently, precisely generate test sheets to meet the various assessment requirements than existing ones. Furthermore, according to experimental finding, Fractal Time Series approach can be applied to analyze the self-similarity characteristics of GA’s fitness scores for improving the quality of the test-sheet composition in the near future.

  8. Performance Tests of a Mechanical Pump in Sodium Environment

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chungho; Kim, Jong-Man; Ko, Yung Joo; Kim, Byeongyeon; Cho, Youngil; Jung, Min-Hwan; Gam, Da-Young; Lee, Yong Bum; Jeong, Ji-Young; Kim, Jong-Bum [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    Water is often selected as a surrogate test fluid because it is not only cheap, easily available and easy to handle but also its important hydraulic properties (density and kinematic viscosity) are very similar to that of the sodium. Nevertheless, to ensure the performance, safety, and operability of major components before its installation in the SFR, a series of demonstration experiments of some components in sodium environment should be positively necessary. So, SFR NSSS System Design Division of Korea Atomic Energy Research Institute (KAERI) built various sodium experimental facilities, especially STELLA-1 in 2012. STELLA-1 (Sodium inTegral Effect test Loop for safety simuLation and Assessment) is a large-scale separated effect test facility for demonstrating the thermal-hydraulic performances of major components such as a Sodium-to-Sodium heat exchanger (DHX), Sodium-to-Air heat exchanger (AHX) of the decay heat removal system, and mechanical sodium pump of the primary heat transport system (PHTS). The mechanical pump in-sodium performance test was successfully performed with good reproducibility of the experiment and data to compare hydraulic characteristic of a mechanical pump in-water was collected. In effect of temperature variation on the pump pressure head, reduction of pump pressure head at 250℃ by 0.57% of that of 300℃ maybe the result of an increase in sodium viscosity by 13.6% according to operating temperature decrease by 50℃. Also, we confirmed that the more flywheel weight, the longer halving time and the more initial flow rate when the pump seized, the shorter halving time. The results of the mechanical pump performance test data in sodium environment will be used to compare with that of the in water environment after the evaluation of measurement uncertainty for tests.

  9. Mechanical properties of JT-60 tokamak machine in power tests

    International Nuclear Information System (INIS)

    Takatsu, Hideyuki; Ohkubo, Minoru; Yamamoto, Masahiro; Ohta, Mitsuru

    1986-01-01

    JT-60 power tests were carried out from Dec. 10, 1984 to Feb. 20, 1985 to demonstrate, in advance of actual plasma operation, satisfactory performance of tokamak machine, power suppliers and control system in combination. The tests began with low power test of individual coil systems and progressed to full power tests. The coil current was raised step by step, monitoring the mechanical, thermal, electrical and vacuum data. Power tests were concluded with successful results. All of the coil systems were raised up to full power operation in combination and system performance was verified including the structural integrity of tokamak machine. Measured strain and deflection showed good agreements with those predicted in the design, which was an evidence that electromagnetic forces were supported as expected in the design. A few limitations to machine operation was made clear quantitatively. And it was found that existing detectors were insufficient to monitor machine integrity and two kinds of detector were proposed to be installed. (author)

  10. Specimen's plane misaligned installation solution based on charge fluctuation inside SEM

    Science.gov (United States)

    Lu, Haojian; Liu, Yanting; Yang, Yuanyuan; Wang, Panbing; Shen, Yajing

    2018-04-01

    Precise specimen's installation is a sticking point to ensure the characterization accuracy of the in-situ material property test. Although it is common knowledge that specimen's plane misaligned installation (PMI) would cause extra force loading during mechanical testing, there are few effective solutions available to deal with it at the current stage, especially during the in-situ scanning electron microscopy (SEM) test. Taking into consideration the charge fluctuation phenomenon under SEM, this paper proposes a highlight area variation (HAV) method for specimen deformation judgment, i.e., the specimen deformation is defined when the highlight area changes greater than 20% of the initial value of the specimen surface. Three types of specimens with different resistivities, i.e., human hair (electrical resistivity ˜3 × 1012 Ω cm), optical fiber (electrical resistivity ˜1017 Ω cm), and magnetic wire (electrical resistivity ˜2 × 10-5 Ω cm), are chosen to verify the effectiveness of the HAV method. Furthermore, combined with the developed robot-aided alignment system, the specimen's PMI problem can also be solved. In the demonstration, the human hair specimen is installed across two specimen stages and its in-situ twisting (in 360°) test is implemented. The results clearly indicate that the HAV method and the robot-aided alignment system are practical and reliable, and the specimen can be aligned on the same plane and installed precisely with accuracy up to 3 μm. This method will benefit the in-situ SEM material mechanical property test and has a significant impact in fundamental material research.

  11. Laboratory creep and mechanical tests on salt data report (1975-1996): Waste Isolation Pilot Plant (WIPP) thermal/structural interactions program

    Energy Technology Data Exchange (ETDEWEB)

    Mellegard, K.D. [RE/SPEC Inc., Rapid City, SD (United States); Munson, D.E. [Sandia National Labs., Albuquerque, NM (United States)

    1997-02-01

    The Waste Isolation Pilot Plant (WIPP), a facility located in a bedded salt formation in Carlsbad, New Mexico, is being used by the U.S. Department of Energy to demonstrate the technology for safe handling and disposal of transuranic wastes produced by defense activities in the United States. In support of that demonstration, mechanical tests on salt were conducted in the laboratory to characterize material behavior at the stresses and temperatures expected for a nuclear waste repository. Many of those laboratory test programs have been carried out in the RE/SPEC Inc. rock mechanics laboratory in Rapid City, South Dakota; the first program being authorized in 1975 followed by additional testing programs that continue to the present. All of the WIPP laboratory data generated on salt at RE/SPEC Inc. over the last 20 years is presented in this data report. A variety of test procedures were used in performance of the work including quasi-static triaxial compression tests, constant stress (creep) tests, damage recovery tests, and multiaxial creep tests. The detailed data is presented in individual plots for each specimen tested. Typically, the controlled test conditions applied to each specimen are presented in a plot followed by additional plots of the measured specimen response. Extensive tables are included to summarize the tests that were performed. Both the tables and the plots contain cross-references to the technical reports where the data were originally reported. Also included are general descriptions of laboratory facilities, equipment, and procedures used to perform the work.

  12. Multiaxial pedicle screw designs: static and dynamic mechanical testing.

    Science.gov (United States)

    Stanford, Ralph Edward; Loefler, Andreas Herman; Stanford, Philip Mark; Walsh, William R

    2004-02-15

    Randomized investigation of multiaxial pedicle screw mechanical properties. Measure static yield and ultimate strengths, yield stiffness, and fatigue resistance according to an established model. Compare these measured properties with expected loads in vivo. Multiaxial pedicle screws provide surgical versatility, but the complexity of their design may reduce their strength and fatigue resistance. There is no published data on the mechanical properties of such screws. Screws were assembled according to a vertebrectomy model for destructive mechanical testing. Groups of five assemblies were tested in static tension and compression and subject to three cyclical loads. Modes of failure, yield, and ultimate strength, yield stiffness, and cycles to failure were determined for six designs of screw. Static compression yield loads ranged from 217.1 to 388.0 N and yield stiffness from 23.7 to 38.0 N/mm. Cycles to failure ranged from 42 x 10(3) to 4,719 x 10(3) at 75% of static ultimate load. There were significant differences between designs in all modes of testing. Failure occurred at the multiaxial link in static and cyclical compression. Bending yield strengths just exceeded loads expected in vivo. Multiaxial designs had lower static bending yield strength than fixed screw designs. Five out of six multiaxial screw designs achieved one million cycles at 200 N in compression bending. "Ball-in-cup" multiaxial locking mechanisms were vulnerable to fatigue failure. Smooth surfaces and thicker material appeared to be protective against fatigue failure.

  13. Mechanical Testing of Carbon Based Woven Thermal Protection Materials

    Science.gov (United States)

    Pham, John; Agrawal, Parul; Arnold, James O.; Peterson, Keith; Venkatapathy, Ethiraj

    2013-01-01

    Three Dimensional Woven thermal protection system (TPS) materials are one of the enabling technologies for mechanically deployable hypersonic decelerator systems. These materials have been shown capable of serving a dual purpose as TPS and as structural load bearing members during entry and descent operations. In order to ensure successful structural performance, it is important to characterize the mechanical properties of these materials prior to and post exposure to entry-like heating conditions. This research focuses on the changes in load bearing capacity of woven TPS materials after being subjected to arcjet simulations of entry heating. Preliminary testing of arcjet tested materials [1] has shown a mechanical degradation. However, their residual strength is significantly more than the requirements for a mission to Venus [2]. A systematic investigation at the macro and microstructural scales is reported here to explore the potential causes of this degradation. The effects of heating on the sizing (an epoxy resin coating used to reduce friction and wear during fiber handling) are discussed as one of the possible causes for the decrease in mechanical properties. This investigation also provides valuable guidelines for margin policies for future mechanically deployable entry systems.

  14. The measurement of power losses at high magnetic field densities or at small cross-section of test specimen using the averaging

    CERN Document Server

    Gorican, V; Hamler, A; Nakata, T

    2000-01-01

    It is difficult to achieve sufficient accuracy of power loss measurement at high magnetic field densities where the magnetic field strength gets more and more distorted, or in cases where the influence of noise increases (small specimen cross section). The influence of averaging on the accuracy of power loss measurement was studied on the cast amorphous magnetic material Metglas 2605-TCA. The results show that the accuracy of power loss measurements can be improved by using the averaging of data acquisition points.

  15. The relative test performance characteristics of two commercial assays for the detection of Mycobacterium tuberculosis complex in paraffin-fixed human biopsy specimens

    Directory of Open Access Journals (Sweden)

    Broukhanski George

    2008-09-01

    Full Text Available Abstract The Seeplex™ TB Detection-2 assay (Rockville, MD is a nested endpoint PCR for the Mycobacterium tuberculosis complex (MTBC targets IS6110 and MPB64 that utilizes dual priming oligonucleotide technology. When used to detect the presence of MTBC DNA in formalin-fixed paraffin-embedded tissue specimens, the sensitivity and specificity of this assay is equivalent to a labor-intensive traditional endpoint PCR assay and is more sensitive than a commercial real-time PCR assay.

  16. Ultrasound-based testing of tendon mechanical properties

    DEFF Research Database (Denmark)

    Seynnes, O R; Bojsen-Møller, J.; Albracht, K

    2015-01-01

    In the past 20 years, the use of ultrasound-based methods has become a standard approach to measure tendon mechanical properties in vivo. Yet the multitude of methodological approaches adopted by various research groups probably contribute to the large variability of reported values. The technique......, or signal synchronization; and 2) in physiological considerations related to the viscoelastic behavior or length measurements of tendons. Hence, the purpose of the present review is to assess and discuss the physiological and technical aspects connected to in vivo testing of tendon mechanical properties...

  17. Regional and depth variability of porcine meniscal mechanical properties through biaxial testing.

    Science.gov (United States)

    Kahlon, A; Hurtig, M B; Gordon, K D

    2015-01-01

    The menisci in the knee joint undergo complex loading in-vivo resulting in a multidirectional stress distribution. Extensive mechanical testing has been conducted to investigate the tissue properties of the knee meniscus, but the testing conditions do not replicate this complex loading regime. Biaxial testing involves loading tissue along two different directions simultaneously, which more accurately simulates physiologic loading conditions. The purpose of this study was to report mechanical properties of meniscal tissue resulting from biaxial testing, while simultaneously investigating regional variations in properties. Ten left, fresh porcine joints were obtained, and the medial and lateral menisci were harvested from each joint (twenty menisci total). Each menisci was divided into an anterior, middle and posterior region; and three slices (femoral, deep and tibial layers) were obtained from each region. Biaxial and constrained uniaxial testing was performed on each specimen, and Young's moduli were calculated from the resulting stress strain curves. Results illustrated significant differences in regional mechanical properties, with the medial anterior (Young's modulus (E)=11.14 ± 1.10 MPa), lateral anterior (E=11.54 ± 1.10 MPa) and lateral posterior (E=9.0 ± 1.2 MPa) regions exhibiting the highest properties compared to the medial central (E=5.0 ± 1.22 MPa), medial posterior (E=4.16 ± 1.13 MPa) and lateral central (E=5.6 ± 1.20 MPa) regions. Differences with depth were also significant on the lateral meniscus, with the femoral (E=12.7 ± 1.22 MPa) and tibial (E=8.6 ± 1.22 MPa) layers exhibiting the highest Young's moduli. This data may form the basis for future modeling of meniscal tissue, or may aid in the design of synthetic replacement alternatives. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Development of a load cell for mechanical testing in hydrogen

    International Nuclear Information System (INIS)

    McCabe, L.P.

    1982-01-01

    Mechanical testing in hydrogen environments is performed on materials to determine hydrogen compatibility. Many tests are performed on small test samples in pressure vessels where monitoring of actual sample load is difficult. A method was developed to monitor small samples by placing inside the vessel a miniature load cell which is capable of measuring loads of less than 100 lbs. The load cell monitors load by means of a Wheatstone Bridge circuit composed of four strain gages. Two of the gages are mounted on a stainless steel stub which becomes part of the vessel load string; the others are wired outside the pressure vessel. Previously, load cells have been short-lived because of hydrogen diffusion into the epoxy-phenolic adhesive used to attach the strain gages to the stub. The use of a flame-sprayed ceramic, however, rather than an organic epoxy to mount the strain gages appears to produce a load cell resistant to the hydrogen test environment

  19. Controlled Environment Specimen Transfer

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Zandbergen, Henny W.; Hansen, Thomas Willum

    2014-01-01

    an environmental transmission electron microscope to an in situ X-ray diffractometer through a dedicated transmission electron microscope specimen transfer holder, capable of sealing the specimen in a gaseous environment at elevated temperatures. Two catalyst material systems have been investigated; Cu/ZnO/Al2O3...... transferred in a reactive environment to the environmental transmission electron microscope where further analysis on the local scale were conducted. The Co/Al2O3 catalyst was reduced in the environmental microscope and successfully kept reduced outside the microscope in a reactive environment. The in situ......Specimen transfer under controlled environment conditions, such as temperature, pressure, and gas composition, is necessary to conduct successive complementary in situ characterization of materials sensitive to ambient conditions. The in situ transfer concept is introduced by linking...

  20. Interdisciplinary seminar on nondestructive testing and fracture mechanics. Lectures

    International Nuclear Information System (INIS)

    1998-01-01

    The proceedings volume contains 17 lectures presented at a DGZfP seminar held in Berlin/Germany, 2-3 November 1998. Fracture mechanics data are of interest with respect to determining maximum permissible limits for non-destructive materials evaluation, and as quantitative NDE test results indicating existing materials flaws in a system component, delivering information for assessement of remaining service life and safety risks. The topics of lectures are: Quality concepts for welded joints; NDE for service life assessment of engine components, shown for evaluation of engine pales and disks; NDE and crack detection at pressurized gas cylinders; fracture mechanics requirements for NDE in nuclear installations, discussion of practical examples (T. Seidenkranz); failure of off-shore constructions seen in the light of a novel fracture mechanics technical code. (orig./CB) [de

  1. Mechanical test of the model coil wound with large conductor

    International Nuclear Information System (INIS)

    Hiue, Hisaaki; Sugimoto, Makoto; Nakajima, Hideo; Yasukawa, Yukio; Yoshida, Kiyoshi; Hasegawa, Mitsuru; Ito, Ikuo; Konno, Masayuki.

    1992-09-01

    The high rigidity and strength of the winding pack are required to realize the large superconducting magnet for the fusion reactor. This paper describes mechanical tests concerning the rigidity of the winding pack. Samples were prepared to evaluate the adhesive strength between conductors and insulators. Epoxy and Bismaleimide-Triazine resin (BT resin) were used as the conductor insulator. The stainless steel (SS) 304 bars, whose surface was treated mechanically and chemically, was applied to the modeled conductor. The model coil was would with the model conductors covered with the insulator by grand insulator. A winding model combining 3 x 3 conductors was produced for measuring shearing rigidity. The sample was loaded with pure shearing force at the LN 2 temperature. The bar winding sample, by 8 x 6 conductors, was measured the bending rigidity. These three point bending tests were carried out at room temperature. The pancake winding sample was loaded with compressive forces to measure compressive rigidity of winding. (author)

  2. Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study.

    Science.gov (United States)

    Sonmez, Nesrin; Gultekin, Pinar; Turp, Volkan; Akgungor, Gokhan; Sen, Deniz; Mijiritsky, Eitan

    2018-01-08

    Polymer infiltrated ceramics and nano-ceramic resins are the new restorative materials which have been developed in order to enhance the adverse properties of glass-matrix ceramics and resin composites. The aim of the present in vitro study was to evaluate the characteristics of various CAD/CAM materials through mechanical, microstructural, and SEM analysis. Five test groups (n = 22) were formed by using the indicated CAD/CAM blocks: VITA Enamic (VITA Zahnfabrik), Lava Ultimate (3 M ESPE), IPS e.max CAD (Ivoclar Vivadent), IPS Empress CAD (Ivoclar Vivadent), and VITA Mark II (VITA Zahnfabrik). Two specimens from each test group were used for XRD and EDS analysis. Remaining samples were divided into two subgroups (n = 10). One subgroup specimens were thermocycled (5 °C to 55 °C, 30s, 10,000 cycles) whereas the other were not. All of the specimens were evaluated in terms of flexural strength, Vickers hardness, and fracture toughness. Results were statistically analyzed using two-way ANOVA, one-way ANOVA, Tukey's HSD, and Student's t tests (α = .05). Fractured specimens were evaluated using SEM. The highest Vickers microhardness value was found for VITA Mark II (p CAD was found to have the highest flexural strength (p CAD was also higher than other tested block materials (p CAD groups. It should be realised that simulated aging process seem to affect ceramic-polymer composite materials more significantly than glass ceramics.

  3. A Review of Neuropathic Pain: From Diagnostic Tests to Mechanisms

    OpenAIRE

    Truini, Andrea

    2017-01-01

    Neuropathic pain develops when the somatosensory nervous system is affected by a lesion or disease. Diagnostic tests aimed at assessing somatosensory afferent pathway damage are therefore useful for diagnosing neuropathic pain. Neuropathic pain manifests with a range of different symptoms such as ongoing burning pain, squeezing or pressure pain, paroxysmal electric shock-like sensations, stabbing pain, or mechanical dynamic allodynia. The various types of neuropathic pain are associated with ...

  4. Development of a miniaturized bulge test (small punch test) for post-irradiation mechanical property evaluation

    International Nuclear Information System (INIS)

    Eto, Motokuni; Suzuki, Masahide; Nishiyama, Yutaka; Fukaya, Kiyoshi; Jitsukawa, Shiro; Misawa, Toshihei

    1993-01-01

    To examine the effectiveness of the small punch test for evaluating strength and toughness of irradiated ferritic steels, detailed procedures are described aiming at standardization of the test. The statistical approach to analysis of the SP energy as a function of temperature for evaluation of DBTT was also reviewed. The method was then applied to neutron-irradiated ferritic steels, which included F-82, F-82H, HT-9, and 2 1/4 Cr-1Mo steel. Fluence and irradiation temperatures ranged from 2 to 12 x 10 23 n/m 2 (E ≥ 1 MeV) and from 573 to 673 K, respectively. Comparison of parameters obtained from the small punch test with the properties measured by the conventional method indicated that: (a) the 0.2% offset stress and the ultimate tensile strength at room temperature can be correlated well with the parameters, P y /(t 0 ) 2 and P max /(t 0 ) 2 , respectively. Here, P y and P max are the loads corresponding to the yield and the maximum, and t 0 is the initial thickness of a specimen; (b) fracture toughness, J IC , can be evaluated using equivalent fracture strain, anti ε qf , and the previously established relationship between these values; and (c) DBTT measured by a Charpy test can be predicted from the results of temperature dependence of SP energy determined from the area under the load-deflection curve using a statistical analysis based on a Weibull distribution

  5. Development of fatigue life evaluation technique using miniature specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Fujiwara, Masaharu; Hisaka, Tomoaki

    2012-01-01

    To develop the fatigue life evaluation technique using miniature specimen, the investigation of the effect of specimen size and specimen shape on the fatigue life and the development of the fatigue testing machine, especially the extensometer, were carried out. The effect of specimen size on the fatigue life was almost negligible for the round-bar specimens. The shorter fatigue life at relatively low strain range conditions for the hourglass specimen that the standard specimen were observed. Therefore the miniature round-bar specimen was considered to be adequate for the fatigue life evaluation using small specimen. Several types of the extensometer system using a strain gauge and a laser has been developed for realizing the fatigue test of the miniature round-bar specimen at high temperature in vacuum. (author)

  6. Impact of specimen adequacy on the assessment of renal allograft biopsy specimens.

    Science.gov (United States)

    Cimen, S; Geldenhuys, L; Guler, S; Imamoglu, A; Molinari, M

    2016-01-01

    The Banff classification was introduced to achieve uniformity in the assessment of renal allograft biopsies. The primary aim of this study was to evaluate the impact of specimen adequacy on the Banff classification. All renal allograft biopsies obtained between July 2010 and June 2012 for suspicion of acute rejection were included. Pre-biopsy clinical data on suspected diagnosis and time from renal transplantation were provided to a nephropathologist who was blinded to the original pathological report. Second pathological readings were compared with the original to assess agreement stratified by specimen adequacy. Cohen's kappa test and Fisher's exact test were used for statistical analyses. Forty-nine specimens were reviewed. Among these specimens, 81.6% were classified as adequate, 6.12% as minimal, and 12.24% as unsatisfactory. The agreement analysis among the first and second readings revealed a kappa value of 0.97. Full agreement between readings was found in 75% of the adequate specimens, 66.7 and 50% for minimal and unsatisfactory specimens, respectively. There was no agreement between readings in 5% of the adequate specimens and 16.7% of the unsatisfactory specimens. For the entire sample full agreement was found in 71.4%, partial agreement in 20.4% and no agreement in 8.2% of the specimens. Statistical analysis using Fisher's exact test yielded a P value above 0.25 showing that - probably due to small sample size - the results were not statistically significant. Specimen adequacy may be a determinant of a diagnostic agreement in renal allograft specimen assessment. While additional studies including larger case numbers are required to further delineate the impact of specimen adequacy on the reliability of histopathological assessments, specimen quality must be considered during clinical decision making while dealing with biopsy reports based on minimal or unsatisfactory specimens.

  7. [Pathogenic Mechanism and Diagnostic Testing for Drug Allergies].

    Science.gov (United States)

    Uno, Katsuji

    2018-01-01

     Three stages of the pathogenic mechanism of drug allergies can be considered: antigen formation, immune reaction and inflammation/disorder reaction. Drugs are thought to form 4 types of antigens: drug only, polymers, drug-carrier conjugates, and metabolite-carrier complexes. Antigens are recognized by B cell receptors and T cell receptors. Helper T cells (Th) are differentiated into four subsets, namely, Th1, Th2, Th17 and regulatory T cells (Treg). Th1 produces interleukin (IL)-2 and interferon (IFN)-γ, and activates macrophages and cytotoxic T cells (Tc). Macrophages induce type IV allergies, and Tc lead to serious type IV allergies. On the other hand, Th2 produces IL-4, IL-5, and IL-6, etc., and activates B cells. B cells produce IgE antibodies, and the IgE antibody affects mast cells and induces type I allergies. Activated eosinophil leads to the chronic state of type I allergy. Diagnostic testing for allergenic drugs is necessary for patients with drug allergies. Because in vivo diagnostic tests for allergenic drugs are associated with a risk and burden to the patient, in vitro allergy tests are recommended to identify allergenic drugs. In allergy tests performed in vitro, cytological tests are more effective than serological tests, and the leukocyte migration test (LMT) presently has the highest efficacy. An LMT-chamber is better than LMT-agarose in terms of usability and sensitivity, and it can detect about 80% of allergenic drugs.

  8. Mechanical testing of PHWR components at different fabrication stages

    International Nuclear Information System (INIS)

    Saibaba, N.

    2007-01-01

    Zirconium alloys are extensively used for reactor structural and cladding components for PHWRs and BWRs due to their low neutron absorption cross-section, corrosion resistance to high temperature aqueous environments, adequate mechanical properties and resistance to radiation damage. The coolant tube fabrication route consists of a series of intermediate process steps. The working parameters of each process have a definite bearing on the final properties of these tubes. In order to ascertain the effect of these parameters, mechanical testing is carried out at intermediate stage of coolant tube fabrication. The mechanical properties of the products can be correlated with process parameters and reflect the quality of the product to a great extent. These properties at intermediate stages can serve as process controlling parameters. This paper discusses the correlation of mechanical properties of pressure tubes between the intermediate stage and final stage. The effect of process parameters like annealing temperature, honing, sand blasting pressure and eccentricity on the final mechanical properties was highlighted. (author)

  9. Preserve specimens for reproducibility

    Czech Academy of Sciences Publication Activity Database

    Krell, F.-T.; Klimeš, Petr; Rocha, L. A.; Fikáček, M.; Miller, S. E.

    2016-01-01

    Roč. 539, č. 7628 (2016), s. 168 ISSN 0028-0836 Institutional support: RVO:60077344 Keywords : reproducibility * specimen * biodiversity Subject RIV: EH - Ecology, Behaviour Impact factor: 40.137, year: 2016 http://www.nature.com/nature/journal/v539/n7628/full/539168b.html

  10. Mechanical tests for validation of seismic isolation elastomer constitutive models

    International Nuclear Information System (INIS)

    Kulak, R.F.; Hughes, T.H.

    1992-01-01

    High damping laminated elastomeric bearings are becoming the preferred device for seismic isolation of large buildings and structures, such as nuclear power plants. The key component of these bearings is a filled natural rubber elastomer. This material exhibits nonlinear behavior within the normal design range. The material damping cannot be classified as either viscous or hysteritic, but it seems to fall somewhere in between. This paper describes a series of tests that can be used to characterize the mechanical response of these elastomers. The tests are designed to determine the behavior of the elastomer in the time scale of the earthquake, which is typically from 30 to 60 seconds. The test results provide data for use in determining the material parameters associated with nonlinear constitutive models. 4 refs

  11. Degradation mechanisms and accelerated testing in PEM fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Borup, Rodney L [Los Alamos National Laboratory; Mukundan, Rangachary [Los Alamos National Laboratory

    2010-01-01

    The durability of PEM fuel cells is a major barrier to the commercialization of these systems for stationary and transportation power applications. Although there has been recent progress in improving durability, further improvements are needed to meet the commercialization targets. Past improvements have largely been made possible because of the fundamental understanding of the underlying degradation mechanisms. By investigating component and cell degradation modes; defining the fundamental degradation mechanisms of components and component interactions new materials can be designed to improve durability. Various factors have been shown to affect the useful life of PEM fuel cells. Other issues arise from component optimization. Operational conditions (such as impurities in either the fuel and oxidant stream), cell environment, temperature (including subfreezing exposure), pressure, current, voltage, etc.; or transient versus continuous operation, including start-up and shutdown procedures, represent other factors that can affect cell performance and durability. The need for Accelerated Stress Tests (ASTs) can be quickly understood given the target lives for fuel cell systems: 5000 hours ({approx} 7 months) for automotive, and 40,000 hrs ({approx} 4.6 years) for stationary systems. Thus testing methods that enable more rapid screening of individual components to determine their durability characteristics, such as off-line environmental testing, are needed for evaluating new component durability in a reasonable turn-around time. This allows proposed improvements in a component to be evaluated rapidly and independently, subsequently allowing rapid advancement in PEM fuel cell durability. These tests are also crucial to developers in order to make sure that they do not sacrifice durability while making improvements in costs (e.g. lower platinum group metal [PGM] loading) and performance (e.g. thinner membrane or a GDL with better water management properties). To

  12. Testing quantum mechanics using third-order correlations

    International Nuclear Information System (INIS)

    Kinsler, P.

    1996-01-01

    Semiclassical theories similar to stochastic electrodynamics are widely used in optics. The distinguishing feature of such theories is that the quantum uncertainty is represented by random statistical fluctuations. They can successfully predict some quantum-mechanical phenomena; for example, the squeezing of the quantum uncertainty in the parametric oscillator. However, since such theories are not equivalent to quantum mechanics, they will not always be useful. Complex number representations can be used to exactly model the quantum uncertainty, but care has to be taken that approximations do not reduce the description to a hidden variable one. This paper helps show the limitations of open-quote open-quote semiclassical theories,close-quote close-quote and helps show where a true quantum-mechanical treatment needs to be used. Third-order correlations are a test that provides a clear distinction between quantum and hidden variable theories in a way analogous to that provided by the open-quote open-quote all or nothing close-quote close-quote Greenberger-Horne-Zeilinger test of local hidden variable theories. copyright 1996 The American Physical Society

  13. Fracture resistance of welded panel specimen with perpendicular crack in tensile

    International Nuclear Information System (INIS)

    Gochev, Todor; Adziev, Todor

    1998-01-01

    Defects caused by natural crack in welded joints of high-strength low-alloy (HSLA) steels are very often. Perpendicular crack in welded joints and its heat treatment after the welding has also an influence on the fracture resistance. The fracture resistance of welded joints by crack in tense panel specimens was investigated by crack mouse opening displesment (CMOD), the parameter of fracture mechanic. Crack propagation was analysed by using a metallographic analysis of fractured specimens after the test. (Author)

  14. Temperature buffer test. Hydro-mechanical and chemical/ mineralogical characterizations

    International Nuclear Information System (INIS)

    Aakesson, Mattias; Olsson, Siv; Dueck, Ann; Nilsson, Ulf; Karnland, Ola; Kiviranta, Leena; Kumpulainen, Sirpa; Linden, Johan

    2012-01-01

    The Temperature Buffer Test (TBT) is a joint project between SKB/ANDRA and supported by ENRESA (modeling) and DBE (instrumentation), which aims at improving the understanding and to model the thermo-hydro-mechanical behavior of buffers made of swelling clay submitted to high temperatures (over 100 deg C) during the water saturation process. The test has been carried out in a KBS-3 deposition hole at Aspo HRL. It was installed during the spring of 2003. Two steel heaters (3 m long, 0.6 m diameter) and two buffer arrangements have been investigated: the lower heater was surrounded by rings of compacted Wyoming bentonite only, whereas the upper heater was surrounded by a composite barrier, with a sand shield between the heater and the bentonite. The test was dismantled and sampled during the winter of 2009/2010. This report presents the hydro-mechanical and chemical/mineralogical characterization program which was launched subsequent to the dismantling operation. The main goal has been to investigate if any significant differences could be observed between material from the field experiment and the reference material. The field samples were mainly taken from Ring 4 (located at the mid-section around the lower heater), in which the temperature in the innermost part reached 155 deg C. The following hydro-mechanical properties have been determined for the material (test technique within brackets): hydraulic conductivity (swelling pressure device), swelling pressure (swelling pressure device), unconfined compression strength (mechanical press), shear strength (triaxial cell) and retention properties (jar method). The following chemical/mineralogical properties (methods within brackets) were determined: anion analysis of water leachates (IC), chemical composition (ICP/AES+MS, EGA), cation exchange capacity (CEC, Cu-trien method) and exchangeable cations (exchange with NH4, ICPAES), mineralogical composition (XRD and FTIR), element distribution and microstructure (SEM and

  15. Eight plane IPND [Integration Prototype Near Detector] mechanical testing

    International Nuclear Information System (INIS)

    Zhao, A.; Guarino, V.; Wood, K.; Nephew, T.; Ayres, D.

    2008-01-01

    A mechanical test of an 8 plane IPND mechanical prototype, which was constructed using extrusions from the testing/tryout of the 16 cell prototype extrusion die in Argonne National Laboratory, was conducted. There were 4 vertical and 4 horizontal planes in this 8 plane IPND prototype. Each vertical plane had four 16 cell extrusions, while each horizontal plane had six 16 cell extrusions. Each plane was glued together using the formulation of Devcon adhesive, Devcon 60. The vertical extrusions used in the vertical planes shares the same dimensions as the horizontal extrusions in the horizontal planes with the average web thickness of 2.1 mm and the average wall thickness of 3.1 mm. This mechanical prototype was constructed with end-seals on the both ends of the vertical extrusions. The gaps were filled with epoxy between extrusions and end-seals. The overall dimension of IPND is 154.8 by 103.1 by 21.7 inches with the weight of approximately 1200 kg, as shown in a figure. Two similar mechanical tests of 3 layer and 11 layer prototypes have been done in order to evaluate the strength of the adhesive joint between extrusions in the NOvA detector. The test showed that the IPND prototype was able to sustain under the loading of weight of itself and scintillator. Two FEA models were built to verify the measurement data from the test. The prediction from FEA slice model seems correlated reasonably well to the test result, even under a 'rough' estimated condition for the wall thickness (from an untuned die) and an unknown property of 'garage type' extrusion. A full size of FEA 3-D model also agrees very well with the test data from strain gage readings. It is worthy to point out that the stress distribution of the structure is predominantly determined by the internal pressure, while the buckling stability relies more on the loading weight from the extrusions themselves and scintillate. Results of conducted internal pressure tests, including 3- cell, 11-cell and the IPND

  16. Mechanical design and testing of a hot-gas turbine on a test facility

    International Nuclear Information System (INIS)

    Staude, R.

    1981-01-01

    Advanced calculation methods and specific solutions for any particular problem are basic requirements for the mechanical design of hot-gas components for gas turbines. The mechanical design contributes a great deal to the smooth running and operational reliability and thus to the quality of the machine. By reference to an expander, the present paper discusses the strength of hot components, such as the casing and the rotor, for both stationary and transient temperature distribution. Mechanical testing under hot-gas conditions fully confirmed the reliability of the rating and design of the hot-gas turbines supplied by M:A.N.-GHH STERKRADE. (orig.) [de

  17. Processing test of an upgraded mechanical design for PERMCAT reactor

    International Nuclear Information System (INIS)

    Borgognoni, Fabio; Demange, David; Doerr, Lothar; Tosti, Silvano; Welte, Stefan

    2010-01-01

    The PERMCAT membrane reactor is a coaxial combination of a Pd/Ag permeator membrane and a catalyst bed. This device has been proposed for processing fusion reactor plasma exhaust gas. A stream containing tritium (up to 1% of tritium in different chemical forms such as water, methane or molecular hydrogen) is decontaminated in the PERMCAT by counter-current isotopic swamping with protium. Different mechanical designs of the membrane reactor have been proposed to improve robustness and lifetime. The ENEA membrane reactor uses a permeator tube with a length of about 500 mm produced via cold-rolling and diffusion welding of Pd/Ag thin foils: two stainless steel pre-tensioned bellows have been applied to the Pd/Ag tube in order to avoid any significant compressive and bending stresses due to the permeator tube elongation consequent to the hydrogen uptake. An experimental test campaign has been performed using this reactor in order to assess the influence of different operating parameters and to evaluate the overall performance (decontamination factor). Tests have been carried out on two reactor prototypes: a defect-free membrane with complete (infinite) hydrogen selectivity and not perm-selective membrane. In this last case, the study has been aimed at verifying the behaviour of the PERMCAT devices under non-normal (accidental) conditions in the view of providing information for future safety analysis. The paper will present the specific mechanical design and the experimental results of tests based on isotopic exchange between H 2 O and D 2 .

  18. Polymyxin susceptibility testing, interpretative breakpoints and resistance mechanisms: An update.

    Science.gov (United States)

    Bakthavatchalam, Yamuna Devi; Pragasam, Agila Kumari; Biswas, Indranil; Veeraraghavan, Balaji

    2018-03-01

    Emerging multidrug-resistant (MDR) nosocomial pathogens are a great threat. Polymyxins, an old class of cationic polypeptide antibiotic, are considered as last-resort drugs in treating infections caused by MDR Gram-negative bacteria. Increased use of polymyxins in treating critically ill patients necessitates routine polymyxin susceptibility testing. However, susceptibility testing both of colistin and polymyxin B (PMB) is challenging. In this review, currently available susceptibility testing methods are briefly discussed. The multicomponent composition of colistin and PMB significantly influences susceptibility testing. In addition, poor diffusion in the agar medium, adsorption to microtitre plates and the synergistic effect of the surfactant polysorbate 80 with polymyxins have a great impact on the performance of susceptibility testing methods This review also describes recently identified chromosomal resistance mechanisms, including modification of lipopolysaccharide (LPS) with 4-amino-4-deoxy-l-arabinose (L-Ara4-N) and phosphoethanolamine (pEtN) resulting in alteration of the negative charge, as well as the plasmid-mediated colistin resistance determinants mcr-1, mcr-1.2, mcr-2 and mcr-3. Copyright © 2017 International Society for Chemotherapy of Infection and Cancer. Published by Elsevier Ltd. All rights reserved.

  19. Rapid point-of-care testing for epidermal growth factor receptor gene mutations in patients with lung cancer using cell-free DNA from cytology specimen supernatants.

    Science.gov (United States)

    Asaka, Shiho; Yoshizawa, Akihiko; Saito, Kazusa; Kobayashi, Yukihiro; Yamamoto, Hiroshi; Negishi, Tatsuya; Nakata, Rie; Matsuda, Kazuyuki; Yamaguchi, Akemi; Honda, Takayuki

    2018-06-01

    Epidermal growth factor receptor (EGFR) mutations are associated with responses to EGFR tyrosine kinase inhibitors (EGFR-TKIs) in non-small-cell lung cancer (NSCLC). Our previous study revealed a rapid point-of-care system for detecting EGFR mutations. This system analyzes cell pellets from cytology specimens using droplet-polymerase chain reaction (d-PCR), and has a reaction time of 10 min. The present study aimed to validate the performance of the EGFR d-PCR assay using cell-free DNA (cfDNA) from supernatants obtained from cytology specimens. Assay results from cfDNA supernatant analyses were compared with those from cell pellets for 90 patients who were clinically diagnosed with, or suspected of having, lung cancer (80 bronchial lavage fluid samples, nine pleural effusion samples and one spinal fluid sample). EGFR mutations were identified in 12 and 15 cases using cfDNA supernatants and cell pellets, respectively. The concordance rates between cfDNA-supernatant and cell‑pellet assay results were 96.7% [kappa coefficient (K)=0.87], 98.9% (K=0.94), 98.9% (K=0.79) and 98.9% (K=0.79) for total EGFR mutations, L858R, E746_A750del and T790M, respectively. All 15 patients with EGFR mutation-positive results, as determined by EGFR d-PCR assay using cfDNA supernatants or cell pellets, also displayed positive results by conventional EGFR assays using tumor tissue or cytology specimens. Notably, EGFR mutations were even detected in five cfDNA supernatants for which the cytological diagnoses of the corresponding cell pellets were 'suspicious for malignancy', 'atypical' or 'negative for malignancy.' In conclusion, this rapid point-of-care system may be considered a promising novel screening method that may enable patients with NSCLC to receive EGFR-TKI therapy more rapidly, whilst also reserving cell pellets for additional morphological and molecular analyses.

  20. Testing quantum mechanics at Da{phi}Ne

    Energy Technology Data Exchange (ETDEWEB)

    Di Domenica, A. [Rome Univ. 2 (Italy). Dipt. di Fisica

    1997-12-31

    After a brief introduction to EPR-paradox and Bell`s inequality, it is shown that a Bell-like inequality can be formulated for the neutral kaon system at a {Phi}-factory using the Pauli spin formalism, in our case called K-spin, and taking into account CP violation. Experimental methods to reveal tiny violations of this inequality by quantum mechanics are discussed. The statistical accuracy achievable at DA{Phi}NE, the Frascati {Phi}-factory, seems adequate to successfully perform such a test. (author) 13 refs.

  1. Testing quantum mechanics at DaφNe

    International Nuclear Information System (INIS)

    Di Domenica, A.

    1997-01-01

    After a brief introduction to EPR-paradox and Bell's inequality, it is shown that a Bell-like inequality can be formulated for the neutral kaon system at a Φ-factory using the Pauli spin formalism, in our case called K-spin, and taking into account CP violation. Experimental methods to reveal tiny violations of this inequality by quantum mechanics are discussed. The statistical accuracy achievable at DAΦNE, the Frascati Φ-factory, seems adequate to successfully perform such a test. (author)

  2. Precracking of WC-Co-hardmetal-specimens for fracture-toughness testing. Anrisserzeugung in WC-Co-Hartmetall-Proben fuer die Messung des kritischen Spannungsintensitaetsfaktors K sub IC

    Energy Technology Data Exchange (ETDEWEB)

    Wissmeier, H.J.; Engel, U. (Erlangen-Nuernberg Univ., Erlangen (Germany, F.R.). Lehrstuhl fuer Fertigungstechnologie)

    1989-09-01

    The determination of a valid critical stress intensity factor K{sub IC} requires an extremely sharp, well defined initial crack. Methods producing such a crack are well known for metallic materials, but they often can not be used with brittle materials, like cemented carbides or ceramics. Their low fracture toughness makes a controlled crack growth under pure tensile stress nearly impossible. More useful are precracking methods, utilizing a stress gradient to stop the crack at defined depth. A very simple method uses the indentation of a hardness tester to produce a semi-elliptical surface crack, interfered with residual stresses. For different areas of application and specimen geometries, bridge indentation, wedge indentation and composite bending method produce cracks with a straight front. Also under cyclic loading, under tensile as well as under compressive stress, the creation of a sharp precrack, applicable in K{sub IC} measurement, is possible. (orig.).

  3. Nonlinear Fracture Mechanics and Plasticity of the Split Cylinder Test

    DEFF Research Database (Denmark)

    Olesen, John Forbes; Østergaard, Lennart; Stang, Henrik

    2006-01-01

    properties. This implies that the linear elastic interpretation of the ultimate splitting force in term of the uniaxial tensile strength of the material is only valid for special situations, e.g. for very large cylinders. Furthermore, the numerical analysis suggests that the split cylinder test is not well...... models are presented, a simple semi-analytical model based on analytical solutions for the crack propagation in a rectangular prismatic body, and a finite element model including plasticity in bulk material as well as crack propagation in interface elements. A numerical study applying these models...... demonstrates the influence of varying geometry or constitutive properties. For a split cylinder test in load control it is shown how the ultimate load is either plasticity dominated or fracture mechanics dominated. The transition between the two modes is related to changes in geometry or constitutive...

  4. Online recruitment and testing of infants with Mechanical Turk.

    Science.gov (United States)

    Tran, Michelle; Cabral, Laura; Patel, Ronak; Cusack, Rhodri

    2017-04-01

    Testing infants in the laboratory is expensive in time and money; consequently, many studies are underpowered, reducing their reproducibility. We investigated whether the online platform, Amazon Mechanical Turk (MTurk), could be used as a resource to more easily recruit and measure the behavior of infant populations. Using a looking time paradigm, with users' webcams we recorded how long infants aged 5 to 8months attended while viewing children's television programs. We found that infants (N=57) were more reliably engaged by some movies than by others and that the most engaging movies could maintain attention for approximately 70% of a 10- to 13-min period. We then identified the cinematic features within the movies. Faces, singing-and-rhyming, and camera zooms were found to increase infant attention. Together, we established that MTurk can be used as a rapid tool for effectively recruiting and testing infants. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  5. Neutron polarimetric test of Leggett's contextual model of quantum mechanics

    International Nuclear Information System (INIS)

    Schmitzer, C.; Bartosik, H.; Klepp, J.; Sponar, S.; Badurek, G.; Hasegawa, J.

    2009-01-01

    Full text: The Einstein-Podolsky-Rosen (EPR) argument attempted to dispute quantum theory. With the Bell inequality it was possible to set up an experimental test of the EPR argument. Here, we describe the rebuilding of the measurement station at the tangential beam exit of the TRIGA reactor of the Atominstitut in Vienna. A new polarimeter setup was constructed and adjusted to generate Bell states by entangling a neutron's energy and spin. After accomplishing visibilities of up to 98.7 %, it was possible to test a Leggett-type inequality, which challenges a 'contextual' hidden variable theory. Such a contextual model would have been capable of reproducing former Bell inequality violations. Measurement results of this Leggett inequality and a generalized Clauser-Horne-Shimony-Holt (CHSH) inequality show violations of this hidden variable model. Hence noncontextual and contextual hidden variable theories can be excluded simultaneously and quantum mechanical predictions are confirmed. (author)

  6. THE ECCENTRIC KOZAI MECHANISM FOR A TEST PARTICLE

    International Nuclear Information System (INIS)

    Lithwick, Yoram; Naoz, Smadar

    2011-01-01

    We study the dynamical evolution of a test particle that orbits a star in the presence of an exterior massive planet, considering octupole-order secular interactions. In the standard Kozai mechanism (SKM), the planet's orbit is circular and so the particle conserves vertical angular momentum. As a result, the particle's orbit oscillates periodically, exchanging eccentricity for inclination. However, when the planet's orbit is eccentric, the particle's vertical angular momentum varies and its Kozai oscillations are modulated on longer timescales—we call this the eccentric Kozai mechanism (EKM). The EKM can lead to behavior that is dramatically different from the SKM. In particular, the particle's orbit can flip from prograde to retrograde and back again, and it can reach arbitrarily high eccentricities given enough time. We map out the conditions under which this dramatic behavior (flipping and extreme eccentricities) occurs and show that when the planet's eccentricity is sufficiently high, it occurs quite generically. For example, when the planet's eccentricity exceeds a few percent of the ratio of semimajor axes (outer to inner), around half of randomly oriented test particle orbits will flip and reach extreme eccentricities. The SKM has often been invoked for bringing pairs of astronomical bodies (star-star, planet-star, compact-object pairs) close together. Including the effect of the EKM will enhance the rate at which such matchmaking occurs.

  7. Development of Testing Methodologies for the Mechanical Properties of MEMS

    Science.gov (United States)

    Ekwaro-Osire, Stephen

    2003-01-01

    This effort is to investigate and design testing strategies to determine the mechanical properties of MicroElectroMechanical Systems (MEMS) as well as investigate the development of a MEMS Probabilistic Design Methodology (PDM). One item of potential interest is the design of a test for the Weibull size effect in pressure membranes. The Weibull size effect is a consequence of a stochastic strength response predicted from the Weibull distribution. Confirming that MEMS strength is controlled by the Weibull distribution will enable the development of a probabilistic design methodology for MEMS - similar to the GRC developed CARES/Life program for bulk ceramics. However, the primary area of investigation will most likely be analysis and modeling of material interfaces for strength as well as developing a strategy to handle stress singularities at sharp corners, filets, and material interfaces. This will be a continuation of the previous years work. The ultimate objective of this effort is to further develop and verify the ability of the Ceramics Analysis and Reliability Evaluation of Structures Life (CARES/Life) code to predict the time-dependent reliability of MEMS structures subjected to multiple transient loads.

  8. Versatile equipment for mechanical testing of active materials

    International Nuclear Information System (INIS)

    Bertsch, Johannes; Heimgartner, Peter

    2005-01-01

    At the Paul Scherrer Institute (PSI) 3 different project groups presently perform aging research on active materials. The research fields are fusion, high neutron flux targets and LWR relevant components. Up to now mechanical testing has been performed with small, low dose rate samples behind local shielding, not appropriate for highly activated material. To overcome this situation, a cell concept for active mechanical testing was elaborated and has been erected in PSI's Hotlab. It consists of 4 shielded cells. 3 connected cells are versatile and independently operable for highly beta/gamma active samples. One cell is an alpha/beta/gamma-box which will be realized in a second phase. This paper presents the versatility especially of the beta/gamma-cells: The different user groups perform experiments in these cells, whereas different machines can be placed into the cells. As consequence of the need of heavily shielded cell doors, a special strengthening and levelling of the floor has been required. In all cells the relevant media are installed. Besides the performance of the cells, the project progress as the difficulties and their solutions are described. (Author)

  9. Processing test of an upgraded mechanical design for PERMCAT reactor

    Energy Technology Data Exchange (ETDEWEB)

    Borgognoni, Fabio, E-mail: fabio.borgognoni@enea.i [Associazione ENEA-Euratom sulla Fusione, C.R. ENEA Frascati, Via E. Fermi 45, Frascati, Roma I-00044 (Italy); Demange, David; Doerr, Lothar [Forschungszentrum Karlsruhe GmbH, Institute for Technical Physics, Tritium Laboratory Karlsruhe, Postfach 3640, D-76021 Karlsruhe (Germany); Tosti, Silvano [Associazione ENEA-Euratom sulla Fusione, C.R. ENEA Frascati, Via E. Fermi 45, Frascati, Roma I-00044 (Italy); Welte, Stefan [Forschungszentrum Karlsruhe GmbH, Institute for Technical Physics, Tritium Laboratory Karlsruhe, Postfach 3640, D-76021 Karlsruhe (Germany)

    2010-12-15

    The PERMCAT membrane reactor is a coaxial combination of a Pd/Ag permeator membrane and a catalyst bed. This device has been proposed for processing fusion reactor plasma exhaust gas. A stream containing tritium (up to 1% of tritium in different chemical forms such as water, methane or molecular hydrogen) is decontaminated in the PERMCAT by counter-current isotopic swamping with protium. Different mechanical designs of the membrane reactor have been proposed to improve robustness and lifetime. The ENEA membrane reactor uses a permeator tube with a length of about 500 mm produced via cold-rolling and diffusion welding of Pd/Ag thin foils: two stainless steel pre-tensioned bellows have been applied to the Pd/Ag tube in order to avoid any significant compressive and bending stresses due to the permeator tube elongation consequent to the hydrogen uptake. An experimental test campaign has been performed using this reactor in order to assess the influence of different operating parameters and to evaluate the overall performance (decontamination factor). Tests have been carried out on two reactor prototypes: a defect-free membrane with complete (infinite) hydrogen selectivity and not perm-selective membrane. In this last case, the study has been aimed at verifying the behaviour of the PERMCAT devices under non-normal (accidental) conditions in the view of providing information for future safety analysis. The paper will present the specific mechanical design and the experimental results of tests based on isotopic exchange between H{sub 2}O and D{sub 2}.

  10. Evaluation of A-1 reactor heavy-water calandria specimens

    International Nuclear Information System (INIS)

    Brumovsky, M.

    1976-01-01

    Container chains with surveillance specimens were placed in two special channels of the core peripheral part to test changes in mechanical properties due to reactor operation of caisson tube material. The specimens were made from the caisson tube material and placed by eight pieces on the outer surface of the containers. The first removed specimens were tested for corrosion losses, tensile strength, and fractured surfaces were then assessed. The changes in strength properties were found to be similar in both base material and welded joints. The corrosion film on surveillance specimens did not practically affect strength properties nor ductility. It was found that the Al-Mg-Si alloy used for the heavy water vessel caisson tubes following stabilization annealing was fully stable at operating temperatures of up to 100 degC. Slio.ht changes in properties can be attributed to the effect of a high neutron dose. Thus, the high radiation and temperature stability of the alloy was confirmed. (O.K.)

  11. Statistical characteristics of mechanical heart valve cavitation in accelerated testing.

    Science.gov (United States)

    Wu, Changfu; Hwang, Ned H C; Lin, Yu-Kweng M

    2004-07-01

    Cavitation damage has been observed on mechanical heart valves (MHVs) undergoing accelerated testing. Cavitation itself can be modeled as a stochastic process, as it varies from beat to beat of the testing machine. This in-vitro study was undertaken to investigate the statistical characteristics of MHV cavitation. A 25-mm St. Jude Medical bileaflet MHV (SJM 25) was tested in an accelerated tester at various pulse rates, ranging from 300 to 1,000 bpm, with stepwise increments of 100 bpm. A miniature pressure transducer was placed near a leaflet tip on the inflow side of the valve, to monitor regional transient pressure fluctuations at instants of valve closure. The pressure trace associated with each beat was passed through a 70 kHz high-pass digital filter to extract the high-frequency oscillation (HFO) components resulting from the collapse of cavitation bubbles. Three intensity-related measures were calculated for each HFO burst: its time span; its local root-mean-square (LRMS) value; and the area enveloped by the absolute value of the HFO pressure trace and the time axis, referred to as cavitation impulse. These were treated as stochastic processes, of which the first-order probability density functions (PDFs) were estimated for each test rate. Both the LRMS value and cavitation impulse were log-normal distributed, and the time span was normal distributed. These distribution laws were consistent at different test rates. The present investigation was directed at understanding MHV cavitation as a stochastic process. The results provide a basis for establishing further the statistical relationship between cavitation intensity and time-evolving cavitation damage on MHV surfaces. These data are required to assess and compare the performance of MHVs of different designs.

  12. Mechanical and Vibration Testing of Carbon Fiber Composite Material with Embedded Piezoelectric Sensors

    Science.gov (United States)

    Duffy, Kirsten P.; Lerch, Bradley A.; Wilmoth, Nathan G.; Kray, Nicholas; Gemeinhardt, Gregory

    2012-01-01

    Piezoelectric materials have been proposed as a means of decreasing turbomachinery blade vibration either through a passive damping scheme, or as part of an active vibration control system. For polymer matrix fiber composite (PMFC) blades, the piezoelectric elements could be embedded within the blade material, protecting the brittle piezoceramic material from the airflow and from debris. Before implementation of a piezoelectric element within a PMFC blade, the effect on PMFC mechanical properties needs to be understood. This study attempts to determine how the inclusion of a packaged piezoelectric patch affects the material properties of the PMFC. Composite specimens with embedded piezoelectric patches were tested in four-point bending, short beam shear, and flatwise tension configurations. Results show that the embedded piezoelectric material does decrease the strength of the composite material, especially in flatwise tension, attributable to failure at the interface or within the piezoelectric element itself. In addition, the sensing properties of the post-cured embedded piezoelectric materials were tested, and performed as expected. The piezoelectric materials include a non-flexible patch incorporating solid piezoceramic material, and two flexible patch types incorporating piezoelectric fibers. The piezoceramic material used in these patches was Navy Type-II PZT.

  13. Thermo-hydro-mechanical tests of buffer material

    Energy Technology Data Exchange (ETDEWEB)

    Pintado, X.; Hassan, Md. M.; Martikainen, J. [B and Tech Oy, Helsinki (Finland)

    2013-10-15

    MX-80 bentonite is the reference clay material for the buffer component planned to be used in the deep geological repository for the disposal of spent nuclear fuel in Finland. The buffer presents complex thermo-hydro-mechanical behavior which is modeled with different constitutive models for heat flow, water flow and stress-strain evolution in the buffer. Thermo, hydro and mechanical models need parameters to evaluate the THM-behavior. These modeling parameters were determined by performing series of laboratory experiments as follows: Water retention curve tests were performed on compacted bentonite samples, encompassing a range of initial dry density values from 1397 to 1718 kg/m{sup 3} as the initial water content was around of 5-8 %. The water retention curve was determined by imposing different suctions to the samples and the suctions were then checked using capacitive hygrometer and chilled mirror psychrometer. Oedometer tests were performed on compacted bentonite samples, encompassing a range of initial dry density values from 1590 to 1750 kg/m{sup 3} as the initial water content was around of 6 %. Samples were saturated with tap water, 35 or 70 g/L salt solutions. Infiltration tests were performed on compacted unsaturated bentonite samples, encompassing a range of initial dry density values from 1400 to 1720 kg/m{sup 3} as the initial water content was approximately between 4-7 %. Samples were saturated with tap water, 0.87, 35 or 70 g/L salt solutions. Tortuosity tests were performed on bentonite samples, encompassing a range of dry density values from 1460 to 1750 kg/m{sup 3} and the degree of saturation varied between 33-93 %. Thermal conductivity tests were performed on compacted bentonite samples, encompassing a range of dry density values from 1545 to 1715 kg/m{sup 3} and the degree of saturation varied between 31-88 %. The measurement was performed using a thermal needle probe. The general trend of all analyzed parameters was as expected when dry

  14. Thermo-hydro-mechanical tests of buffer material

    International Nuclear Information System (INIS)

    Pintado, X.; Hassan, Md. M.; Martikainen, J.

    2013-10-01

    MX-80 bentonite is the reference clay material for the buffer component planned to be used in the deep geological repository for the disposal of spent nuclear fuel in Finland. The buffer presents complex thermo-hydro-mechanical behavior which is modeled with different constitutive models for heat flow, water flow and stress-strain evolution in the buffer. Thermo, hydro and mechanical models need parameters to evaluate the THM-behavior. These modeling parameters were determined by performing series of laboratory experiments as follows: Water retention curve tests were performed on compacted bentonite samples, encompassing a range of initial dry density values from 1397 to 1718 kg/m 3 as the initial water content was around of 5-8 %. The water retention curve was determined by imposing different suctions to the samples and the suctions were then checked using capacitive hygrometer and chilled mirror psychrometer. Oedometer tests were performed on compacted bentonite samples, encompassing a range of initial dry density values from 1590 to 1750 kg/m 3 as the initial water content was around of 6 %. Samples were saturated with tap water, 35 or 70 g/L salt solutions. Infiltration tests were performed on compacted unsaturated bentonite samples, encompassing a range of initial dry density values from 1400 to 1720 kg/m 3 as the initial water content was approximately between 4-7 %. Samples were saturated with tap water, 0.87, 35 or 70 g/L salt solutions. Tortuosity tests were performed on bentonite samples, encompassing a range of dry density values from 1460 to 1750 kg/m 3 and the degree of saturation varied between 33-93 %. Thermal conductivity tests were performed on compacted bentonite samples, encompassing a range of dry density values from 1545 to 1715 kg/m 3 and the degree of saturation varied between 31-88 %. The measurement was performed using a thermal needle probe. The general trend of all analyzed parameters was as expected when dry density, water content, and

  15. Intelligent Test Mechanism Design of Worn Big Gear

    Directory of Open Access Journals (Sweden)

    Hong-Yu LIU

    2014-10-01

    Full Text Available With the continuous development of national economy, big gear was widely applied in metallurgy and mine domains. So, big gear plays an important role in above domains. In practical production, big gear abrasion and breach take place often. It affects normal production and causes unnecessary economic loss. A kind of intelligent test method was put forward on worn big gear mainly aimed at the big gear restriction conditions of high production cost, long production cycle and high- intensity artificial repair welding work. The measure equations transformations were made on involute straight gear. Original polar coordinate equations were transformed into rectangular coordinate equations. Big gear abrasion measure principle was introduced. Detection principle diagram was given. Detection route realization method was introduced. OADM12 laser sensor was selected. Detection on big gear abrasion area was realized by detection mechanism. Tested data of unworn gear and worn gear were led in designed calculation program written by Visual Basic language. Big gear abrasion quantity can be obtained. It provides a feasible method for intelligent test and intelligent repair welding on worn big gear.

  16. NASA Biological Specimen Repository

    Science.gov (United States)

    McMonigal, K. A.; Pietrzyk, R. A.; Sams, C. F.; Johnson, M. A.

    2010-01-01

    The NASA Biological Specimen Repository (NBSR) was established in 2006 to collect, process, preserve and distribute spaceflight-related biological specimens from long duration ISS astronauts. This repository provides unique opportunities to study longitudinal changes in human physiology spanning may missions. The NBSR collects blood and urine samples from all participating ISS crewmembers who have provided informed consent. These biological samples are collected once before flight, during flight scheduled on flight days 15, 30, 60, 120 and within 2 weeks of landing. Postflight sessions are conducted 3 and 30 days after landing. The number of in-flight sessions is dependent on the duration of the mission. Specimens are maintained under optimal storage conditions in a manner that will maximize their integrity and viability for future research The repository operates under the authority of the NASA/JSC Committee for the Protection of Human Subjects to support scientific discovery that contributes to our fundamental knowledge in the area of human physiological changes and adaptation to a microgravity environment. The NBSR will institute guidelines for the solicitation, review and sample distribution process through establishment of the NBSR Advisory Board. The Advisory Board will be composed of representatives of all participating space agencies to evaluate each request from investigators for use of the samples. This process will be consistent with ethical principles, protection of crewmember confidentiality, prevailing laws and regulations, intellectual property policies, and consent form language. Operations supporting the NBSR are scheduled to continue until the end of U.S. presence on the ISS. Sample distribution is proposed to begin with selections on investigations beginning in 2017. The availability of the NBSR will contribute to the body of knowledge about the diverse factors of spaceflight on human physiology.

  17. Rotating specimen rack repair

    International Nuclear Information System (INIS)

    Miller, G.E.; Rogers, P.J.; Nabor, W.G.; Bair, H.

    1984-01-01

    In 1980, an operator at the UCI TRIGA Reactor noticed difficulties with the rotation of the specimen rack. Investigations showed that the drive bearing in the rack had failed and allowed the bearings to enter the rack. After some time of operation in static mode it was decided that installation of a bearing substitute - a graphite sleeve - would be undertaken. Procedures were written and approved for removal of the rack, fabrication and installation of the sleeve, and re-installation of the rack. This paper describes these procedures in some detail. Detailed drawings of the necessary parts may be obtained from the authors

  18. Method for thinning specimen

    Science.gov (United States)

    Follstaedt, David M.; Moran, Michael P.

    2005-03-15

    A method for thinning (such as in grinding and polishing) a material surface using an instrument means for moving an article with a discontinuous surface with an abrasive material dispersed between the material surface and the discontinuous surface where the discontinuous surface of the moving article provides an efficient means for maintaining contact of the abrasive with the material surface. When used to dimple specimens for microscopy analysis, a wheel with a surface that has been modified to produce a uniform or random discontinuous surface significantly improves the speed of the dimpling process without loss of quality of finish.

  19. An investigation on the fatigue behavior of DCB specimen bonded with aluminum foam at Mode III

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. H.; Cho, J. U. [Kongju University, Cheonan (Korea, Republic of); Zhao, G [School of Aerospace, Xian Jiaotong University, Xian (China); Cho, C. [Dept. of Mechanical Engineering, Inha University, Incheon (Korea, Republic of)

    2016-10-15

    Aluminum foam with its excellent physical and mechanical characteristics is a lightweight metallic material used with good quality in vehicle bumpers, internal shock absorbers on planes, as materials for vessel joints etc. On the contrary, when aluminum foam is used without sufficient investigation, there is the likelihood of damage or destruction of the machine or mechanical structure, and in extreme case it may cause to human casualties. This study aims to analyze the characteristics of adhesive structures with aluminum foam for the closed-type aluminum foam used primarily as shock absorbers. The fatigue analyses of the DCB test specimens at mode III with aluminum foam are verified through a fatigue experiment. As the analysis results, test specimen models with the thicknesses (t) of 35 mm, 45 mm and 55 mm showed the peak load occurrence approximately after the progress from 0 to 50 cycles. And afterwards the load gradually decreased as the cycles increased. The peak loads for each DCB test specimens were ±0.80 kN for the specimen thickness(t) of 35 mm, ±0.98 kN for the specimen thickness(t) of 45 mm and ±1.18 kN for the specimen thickness(t) of 55 mm. It is also shown that the peak load occurring on the specimen increased as specimen thickness increased. These study results are compared with the specimen thickness of 35 mm model as the basis. When the specimen thickness is increased as much as 10 mm, the peak load is increased approximately 1.25 times. When the specimen thickness is also increased as much as 20 mm, the peak load is increased 1.5 times. The analysis data and the real experiment data showed similar results each other. Therefore, it can be thought that the analysis data is applicable in real field. And it is estimated that the mechanical characteristics of the DCB test specimen at mode III during the fatigue load conditions can be systematically and efficiently analyzed.

  20. Experimental and numerical analysis concerning the behaviour of OL50 steel grade specimens coated with polyurea layer under dynamics loadings

    Directory of Open Access Journals (Sweden)

    Bucur Florina

    2015-01-01

    Full Text Available This study refers to an experimental and numerical evaluation of a polyurea coating layer influence on the dynamic behaviour of OL50 specimens. Mechanical quasi-static and dynamic tensile tests were performed in axial loading conditions, for 2 mm steel plate specimens. Several metallic specimens have been previously coated with 1.5 mm and 3 mm respectively thickness polyurea layer and tested in traction. The findings results indicate that the presence of polyurea changes the loading pattern of metallic material in the necking area. In terms of polyurea coated metal specimens fracture, there was clearly observed a change of fracture limit. One possible explanation of this phenomenon is the modification of triaxiality state in the necking zone, fact proven by the numerical simulations. Test results indicate that the presence of polyurea layer delays the necking onset phenomenon which precedes the OL50 metallic specimen fracture.

  1. Mechanical characterization and force-displacement hysteretic curves from in-plane cyclic tests on strong masonry infills.

    Science.gov (United States)

    Morandi, Paolo; Hak, Sanja; Magenes, Guido

    2018-02-01

    This article contains information related to a recent study "Performance-based interpretation of in-plane cyclic tests on RC frames with strong masonry infills" (Morandi et al., 2017 [1]). Motivated by the necessity to improve the knowledge of the in-plane seismic response of rigid strong masonry infills, a wide experimental campaign based on in-plane cyclic tests on full-scale RC infilled frame specimens, supplemented with a complete characterization of the materials, has been conducted at the laboratory of the Department of Civil Engineering and Architecture of the University of Pavia. The masonry is constituted by vertically perforated 35 cm thick clay units with tongue and groove and dry head-joints and general-purpose mortar bed-joints. The paper reports the results of the mechanical characterization and of the force-displacement hysteretic curves from the in-plane cyclic tests.

  2. Mechanical characterization and force-displacement hysteretic curves from in-plane cyclic tests on strong masonry infills

    Directory of Open Access Journals (Sweden)

    Paolo Morandi

    2018-02-01

    Full Text Available This article contains information related to a recent study “Performance-based interpretation of in-plane cyclic tests on RC frames with strong masonry infills” (Morandi et al., 2017 [1]. Motivated by the necessity to improve the knowledge of the in-plane seismic response of rigid strong masonry infills, a wide experimental campaign based on in-plane cyclic tests on full-scale RC infilled frame specimens, supplemented with a complete characterization of the materials, has been conducted at the laboratory of the Department of Civil Engineering and Architecture of the University of Pavia. The masonry is constituted by vertically perforated 35 cm thick clay units with tongue and groove and dry head-joints and general-purpose mortar bed-joints. The paper reports the results of the mechanical characterization and of the force-displacement hysteretic curves from the in-plane cyclic tests.

  3. Development of fatigue life evaluation method using small specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Wakai, Eichi; Tanigawa, Hiroyasu; Itoh, Takamoto; Hasegawa, Akira

    2013-01-01

    For developing the fatigue life evaluation method using small specimen, the effect of specimen size and shape on the fatigue life of the reduced activation ferritic/martensitic steels (F82H-IEA, F82H-BA07 and JLF-1) was investigated by the fatigue test at room temperature in air using round-bar and hourglass specimens with various specimen sizes (test section diameter: 0.85–10 mm). The round-bar specimen showed no specimen size and no specimen shape effects on the fatigue life, whereas the hourglass specimen showed no specimen size effect and obvious specimen shape effect on it. The shorter fatigue life of the hourglass specimen observed under low strain ranges could be attributed to the shorter micro-crack initiation life induced by the stress concentration dependent on the specimen shape. On the basis of this study, the small round-bar specimen was an acceptable candidate for evaluating the fatigue life using small specimen

  4. Analysis of the structural behaviour of colonic segments by inflation tests: Experimental activity and physio-mechanical model.

    Science.gov (United States)

    Carniel, Emanuele L; Mencattelli, Margherita; Bonsignori, Gabriella; Fontanella, Chiara G; Frigo, Alessandro; Rubini, Alessandro; Stefanini, Cesare; Natali, Arturo N

    2015-11-01

    A coupled experimental and computational approach is provided for the identification of the structural behaviour of gastrointestinal regions, accounting for both elastic and visco-elastic properties. The developed procedure is applied to characterize the mechanics of gastrointestinal samples from pig colons. Experimental data about the structural behaviour of colonic segments are provided by inflation tests. Different inflation processes are performed according to progressively increasing top pressure conditions. Each inflation test consists of an air in-flow, according to an almost constant increasing pressure rate, such as 3.5 mmHg/s, up to a prescribed top pressure, which is held constant for about 300 s to allow the development of creep phenomena. Different tests are interspersed by 600 s of rest to allow the recovery of the tissues' mechanical condition. Data from structural tests are post-processed by a physio-mechanical model in order to identify the mechanical parameters that interpret both the non-linear elastic behaviour of the sample, as the instantaneous pressure-stretch trend, and the time-dependent response, as the stretch increase during the creep processes. The parameters are identified by minimizing the discrepancy between experimental and model results. Different sets of parameters are evaluated for different specimens from different pigs. A statistical analysis is performed to evaluate the distribution of the parameters and to assess the reliability of the experimental and computational activities. © IMechE 2015.

  5. Phototoxicity: Its Mechanism and Animal Alternative Test Methods

    Science.gov (United States)

    Park, Hyeonji; Lim, Kyung-Min

    2015-01-01

    The skin exposure to solar irradiation and photoreactive xenobiotics may produce abnormal skin reaction, phototoxicity. Phototoxicity is an acute light-induced response, which occurs when photoreacive chemicals are activated by solar lights and transformed into products cytotoxic against the skin cells. Multifarious symptoms of phototoxicity are identified, skin irritation, erythema, pruritis, and edema that are similar to those of the exaggerated sunburn. Diverse organic chemicals, especially drugs, are known to induce phototoxicity, which is probably from the common possession of UV-absorbing benzene or heterocyclic rings in their molecular structures. Both UVB (290~320 nm) and UVA (320~400 nm) are responsible for the manifestation of phototoxicity. Absorption of photons and absorbed energy (hv) by photoactive chemicals results in molecular changes or generates reactive oxygen species and depending on the way how endogenous molecules are affected by phototoxicants, mechanisms of phototoxcity is categorized into two modes of action: Direct when unstable species from excited state directly react with the endogenous molecules, and indirect when endogeneous molecules react with secondary photoproducts. In order to identify phototoxic potential of a chemical, various test methods have been introduced. Focus is given to animal alternative test methods, i.e., in vitro, and in chemico assays as well as in vivo. 3T3 neutral red uptake assay, erythrocyte photohemolysis test, and phototoxicity test using human 3-dimensional (3D) epidermis model are examples of in vitro assays. In chemico methods evaluate the generation of reactive oxygen species or DNA strand break activity employing plasmid for chemicals, or drugs with phototoxic potential. PMID:26191378

  6. Einstein's Materialism and Modern Tests of Quantum Mechanics

    Science.gov (United States)

    Vigier, J. P.

    After a presentation of Einstein's and Bohr's antagonistic point of view on the interpretation of Quantum Mechanics an illustration of their conflicting positions in the particular case of Young's double slit experiment is presented. It is then shown that in their most recent form (i. e. time dependent neutron interferometry) these experiments suggest (if one accepts absolute energymomentum conservation in all individual microprocesses) that Einstein was right in the Bohr-Einstein controversy.Translated AbstractEinsteins Materialismus und heutige Tests der QuantenmechanikNach einer Darstellung von Einsteins und Bohrs antagonistischen Standpunkten in der Interpretation der Quantenmechanik werden ihre widersprüchlichen Positionen im speziellen Fall des Youngschen Doppelspaltexperiments dargestellt. Es wird dann gezeigt, daß diese Experimente in ihrer neuesten Form (d. h. zeitabhängige Neutroneninterferometrie) Einstein in der Bohr-Einsteinkontroverse recht gaben (wenn man absolute Energie-Impulserhaltung bei allen individuellen Mikroprozessen annimmt).

  7. Red Blood Cell Mechanical Fragility Test for Clinical Research Applications.

    Science.gov (United States)

    Ziegler, Luke A; Olia, Salim E; Kameneva, Marina V

    2017-07-01

    Red blood cell (RBC) susceptibility to mechanically induced hemolysis, or RBC mechanical fragility (MF), is an important parameter in the characterization of erythrocyte membrane health. The rocker bead test (RBT) and associated calculated mechanical fragility index (MFI) is a simple method for the assessment of RBC MF. Requiring a minimum of 15.5 mL of blood and necessitating adjustment of hematocrit (Ht) to a "standard" value (40%), the current RBT is not suitable for use in most studies involving human subjects. To address these limitations, we propose a 6.5 mL reduced volume RBT and corresponding modified MFI (MMFI) that does not require prior Ht adjustment. This new method was assessed for i) correlation to the existing text, ii) to quantify the effect of Ht on MFI, and iii) validation by reexamining the protective effect of plasma proteins on RBC MF. The reduced volume RBT strongly correlated (r = 0.941) with the established large volume RBT at matched Hts, and an equation was developed to calculate MMFI: a numerical estimation (R 2  = 0.923) of MFI if performed with the reduced volume RBT at "standard" (40%) Ht. An inversely proportional relationship was found between plasma protein concentration and RBC MF using the MMFI-reduced volume method, supporting previous literature findings. The new reduced volume RBT and modified MFI will allow for the measurement of RBC MF in clinical and preclinical studies involving humans or small animals. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  8. Human papillomavirus detection using the Abbott RealTime high-risk HPV tests compared with conventional nested PCR coupled to high-throughput sequencing of amplification products in cervical smear specimens from a Gabonese female population.

    Science.gov (United States)

    Moussavou-Boundzanga, Pamela; Koumakpayi, Ismaël Hervé; Labouba, Ingrid; Leroy, Eric M; Belembaogo, Ernest; Berthet, Nicolas

    2017-12-21

    Cervical cancer is the fourth most common malignancy in women worldwide. However, screening with human papillomavirus (HPV) molecular tests holds promise for reducing cervical cancer incidence and mortality in low- and middle-income countries. The performance of the Abbott RealTime High-Risk HPV test (AbRT) was evaluated in 83 cervical smear specimens and compared with a conventional nested PCR coupled to high-throughput sequencing (HTS) to identify the amplicons. The AbRT assay detected at least one HPV genotype in 44.57% of women regardless of the grade of cervical abnormalities. Except for one case, good concordance was observed for the genotypes detected with the AbRT assay in the high-risk HPV category determined with HTS of the amplicon generated by conventional nested PCR. The AbRT test is an easy and reliable molecular tool and was as sensitive as conventional nested PCR in cervical smear specimens for detection HPVs associated with high-grade lesions. Moreover, sequencing amplicons using an HTS approach effectively identified the genotype of the hrHPV identified with the AbRT test.

  9. New method to calculate the mechanical properties of unirradiated fuel cladding from ring tensile tests

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Rengel, M.A. [Departamento de Ciencia de Materiales, UPM, E.T.S.I. Caminos, Canales y Puertos, Profesor Aranguren s/n, E-28040 Madrid (Spain); Consejo de Seguridad Nuclear (CSN), Justo Dorado 11, E-28040 Madrid (Spain); Gomez, F.J.; Ruiz-Hervias, J.; Caballero, L.; Valiente, A. [Departamento de Ciencia de Materiales, UPM, E.T.S.I. Caminos, Canales y Puertos, Profesor Aranguren s/n, E-28040 Madrid (Spain)

    2009-06-15

    Nuclear fuel cladding is the first barrier used to confine the fuel and the fission products produced during irradiation. Zirconium alloys are used for this purpose due to their remarkable neutron transparency, together with their good mechanical properties at operational temperatures. Consequently, it is very important to be able to characterize the mechanical response of the irradiated cladding. The mechanical behaviour of the material can be modelled as elastoplastic with different stress-strain curves depending on the direction: radial, hoop or longitudinal direction. The ring tensile test has been proposed to determine the mechanical properties of the cladding along the hoop direction. The initial test consisted of applying a force inside the tube, by means of two half cylinders. Later Arsene and Bai [1,2] modified the experimental device to avoid tube bending at the beginning of the test. The same authors proposed a numerical method to obtain the stress-strain curve in the hoop direction from the experimental load versus displacement results and a given friction coefficient between the loading pieces and the sample [3]. This method has been used by different authors [4] with slight modifications. It is based on the existence of two universal curves under small strain hypothesis: the first correlating the hoop strain and the displacement of the loading piece and the second one correlating the hoop stress and the applied load. In this work, a new method to determine the mechanical properties of the cladding from the ring tensile test results is proposed. Non-linear geometry is considered and an iterative procedure is proposed so universal curves are not needed. A stress-strain curve is determined by combining numerical calculations with experimental results in a convergent loop. The two universal curves proposed by Arsene and Bai [3] are substituted by two relationships, one between the equivalent plastic strain in the centre of the specimen ligament and the

  10. Design optimization and fatigue testing of an electronically-driven mechanically-resonant cantilever spring mechanism

    International Nuclear Information System (INIS)

    Kheng, Lim Boon; Kean, Koay Loke; Gitano-Briggs, Horizon

    2010-01-01

    A light scanning device consisting of an electronically-driven mechanically-resonant cantilever spring-mirror system has been developed for innovative lighting applications. The repeated flexing of the cantilever spring during operation can lead to premature fatigue failure. A model was created to optimize the spring design. The optimized spring design can reduce stress by approximately one-third from the initial design. Fatigue testing showed that the optimized spring design can operate continuously for over 1 month without failure. Analysis of failures indicates surface cracks near the root of the spring are responsible for the failures.

  11. Strength characterization of tubular ceramic materials by flexure of semi-cylindrical specimens

    DEFF Research Database (Denmark)

    Kwok, Kawai; Kiesel, Lutz; Frandsen, Henrik Lund

    2014-01-01

    Mechanical strength at elevated temperatures and operating atmospheres needs to be characterized during development of tubular ceramic components for advanced energy technologies. Typical procedures are time-consuming because a large number of tests are required for a reliable statistical strength...... characterization and every specimen has to be subjected to the process conditions individually. This paper presents an efficient strength characterization methodology for tubular ceramics. The methodology employs flexure of semi-cylindrical specimens as the strength test and implements the tests within a facility...... conducted on oxygen transport membrane materials at room temperature and 850°C....

  12. Mechanisms of eyewitness suggestibility: tests of the explanatory role hypothesis.

    Science.gov (United States)

    Rindal, Eric J; Chrobak, Quin M; Zaragoza, Maria S; Weihing, Caitlin A

    2017-10-01

    In a recent paper, Chrobak and Zaragoza (Journal of Experimental Psychology: General, 142(3), 827-844, 2013) proposed the explanatory role hypothesis, which posits that the likelihood of developing false memories for post-event suggestions is a function of the explanatory function the suggestion serves. In support of this hypothesis, they provided evidence that participant-witnesses were especially likely to develop false memories for their forced fabrications when their fabrications helped to explain outcomes they had witnessed. In three experiments, we test the generality of the explanatory role hypothesis as a mechanism of eyewitness suggestibility by assessing whether this hypothesis can predict suggestibility errors in (a) situations where the post-event suggestions are provided by the experimenter (as opposed to fabricated by the participant), and (b) across a variety of memory measures and measures of recollective experience. In support of the explanatory role hypothesis, participants were more likely to subsequently freely report (E1) and recollect the suggestions as part of the witnessed event (E2, source test) when the post-event suggestion helped to provide a causal explanation for a witnessed outcome than when it did not serve this explanatory role. Participants were also less likely to recollect the suggestions as part of the witnessed event (on measures of subjective experience) when their explanatory strength had been reduced by the presence of an alternative explanation that could explain the same outcome (E3, source test + warning). Collectively, the results provide strong evidence that the search for explanatory coherence influences people's tendency to misremember witnessing events that were only suggested to them.

  13. Mechanical resistance of UO{sub 2} pellet by means of free-fall-impact testing

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Tae-sik; Lee, Seung-jae; Kim, Jae-ik; Jo, Young-ho; Park, Bo-yong; Ko, Sang-ern [KEPCO NF, Daejeon (Korea, Republic of)

    2014-10-15

    A fuel rod failed during a power transient can be seen in Fig 1. and conjunction of a chipped pellet with a cladding crack has been observed in commercial reactors through the post-irradiation examinations. It revealed that missing-pellet-surface(MPS) was one of the reasons of the fuel failure. The mechanism of this failure mode that MPS induces the asymmetry of the pellet-cladding mechanical system mainly comprises a stress concentration at the inner surface resulting in non-classical PCI. The fracture toughness is largely close to material property. It is assumed that by optimizing surface design of UO{sub 2} pellet, the strength arises because theoretical strength is considerably affected by geometry as one of a parameter of factor 'f'. Pellet research for design optimization to achieve better resistance to external load should be accompanied with volumetric approach to the improvement of mechanical behavior of pellet being still ongoing. At this work, the resistance to external load is analyzed varying with the geometry of pellets and angles of impact on UO{sub 2} pellet surface by the free-fall-impact test method. The tested specimens were equivalently produced and sintered for having the same volumetric property such as sinter density and grain size expect the surface with different geometry design at the end face and shoulder which includes dish, chamfer and land in dimension and angle. Missing-pellet-surface(MPS) on UO{sub 2} pellet is inevitable behavior during manufacturing, handling and burning in reactor and brings about non-classical PCI behavior that could damage fuel rod integrity. For this reason, the free-fall-drop tester was developed by KEPCO NF Material Development laboratory in Daejeon for quantitatively investigating the mechanical behavior of UO{sub 2}. The free-fall-impact test is performed by dropping hammer on pellet shoulder with certain impact energy and at various angles. The result is quantitatively measured with weighing

  14. Performance of the Abbott RealTime MTB RIF/INH resistance assay when used to test Mycobacterium tuberculosis specimens from Bangladesh

    Directory of Open Access Journals (Sweden)

    Kostera J

    2018-05-01

    Full Text Available Joshua Kostera, Gregor Leckie, Klara Abravaya, Hong Wang Abbott Molecular, Abbott Laboratories, Des Plaines, IL, USA Introduction: The Abbott RealTime MTB RIF/INH Resistance Assay (RT MTB RIF/INH is an assay for the detection of rifampicin (RIF- and/or isoniazid (INH-resistant Mycobacterium tuberculosis (MTB. The assay can be used to test sputum, bronchial alveolar lavage, and N-Acetyl-L-Cysteine (NALC/NaOH pellets prepared from these samples. The assay can be used in direct testing mode, or in reflex mode following a MTB positive result produced by its companion assay, Abbott RT MTB. Methods: In this study, the direct testing mode was used to test paired sputum and NALC/NaOH pellets prepared from sputum collected from Bangladesh TB patients. One hundred and thirty two paired samples were tested. Results: The RT MTB RIF/INH inhibition rate was 0%. One hundred and twenty-two paired samples had results above the assay limit of detection and were analyzed by comparing with results from phenotypic drug sensitivity testing, GeneXpert MTB/RIF (Xpert, and MTBDR plus (Hain. RT MTB RIF/INH results were in good agreement with those of GeneXpert and Hain. Conclusion: The ability of this assay to detect RIF and INH resistance may contribute to the global control of multidrug resistant tuberculosis. Keywords: tuberculosis, rifampicin, isoniazid, resistance

  15. Mechanical-physical experimental tests on lime mortars and bricks reinforced with hemp

    Science.gov (United States)

    Formisano, Antonio; Dessı, Enzo; Landolfo, Raffaele

    2017-11-01

    Hemp is an agricultural product used for various applications. In the Civil Engineering field, only a limited use of this natural material, called the "green pig" since exploitation of all its constituent parts is allowed, has been done. For this reason, in the paper an experimental activity on lime mortars and bricks reinforced with hemp components has been performed. Compression and bending tests have been carried out on specimens manufactured with hemp shives and fibres, respectively. The achieved results have shown that hemp products change the failure modes from brittle to ductile, leaving basically unaltered the strength capacity of reinforced specimens with respect to unreinforced ones.

  16. Multi-parameter crack tip stress state description for evaluation of nonlinear zone width in silicate composite specimens in component splitting/bending test geometry

    Czech Academy of Sciences Publication Activity Database

    Veselý, V.; Frantík, P.; Sopek, J.; Malíková, L.; Seitl, Stanislav

    2015-01-01

    Roč. 38, č. 2 (2015), s. 200-214 ISSN 8756-758X R&D Projects: GA ČR(CZ) GAP104/11/0833 Institutional support: RVO:68081723 Keywords : near-crack tip fields * Williams series * higher-order terms * stress field * failure criterion * nonlinear zone * quasi-brittle fracture * splitting-bending geometry Subject RIV: JL - Materials Fatigue, Friction Mechanics Impact factor: 1.838, year: 2015

  17. Effect of sized and specimen geometry on the initiation and propagation of the ductile fracture

    International Nuclear Information System (INIS)

    Frund, J.M.; Marini, B.; Bethmont, M.

    1994-02-01

    Strength to the fracture of the pipe in PWR has to be justified with mechanical analyses. These tests are based on the strength to ductile fracture of steels which are tested in lab. The values of resistance to fracture are obtained through tensile tests on CT specimens (determination of J-R curves). The purpose of this study is to justify the sizes of the specimens which have to be used to characterize the strength to ductile fracture of steel in secondary pipes. Tests were conducted on 0,5T-CT, 1T-CT and 2T-CT specimens. Two materials with different suffer contents were studied. The test results show that the JO,2 values gotten from the different specimens are similar. But the strength to ductile fracture in 2T-CT specimens in lower than the one measured in 0,5t-CT and 1T-CT specimens. The surface of fracture of the different specimens displays splits perpendicular to the notch and parallel to the sheet surface. These splits are produced by the separation of the manganese sulfur inclusions. The effect notes on the J-R curves seems to be relevant to these splits. The reason why these splits might be responsible for a decrease of the tearing modulus are not clearly defined up to this point. The results which have been published show the importance of the geometry effects (presence or not of lateral notches...) and the loading mode on the strength to ductile fracture. We note that the curves determined from tests on CT specimens are conservative. A few preliminary studies showed that the geometry effects on resistance to fracture can be studied and explained by using local approach methods. The Rousselier modeling is useful to explain the behaviour of ferritic steels in ductile fracture. (authors). 20 refs., 7 figs., 5 tabs

  18. Elastic-plastic analysis of the SS-3 tensile specimen

    International Nuclear Information System (INIS)

    Majumdar, S.

    1998-01-01

    Tensile tests of most irradiated specimens of vanadium alloys are conducted using the miniature SS-3 specimen which is not ASTM approved. Detailed elastic-plastic finite element analysis of the specimen was conducted to show that, as long as the ultimate to yield strength ratio is less than or equal to 1.25 (which is satisfied by many irradiated materials), the stress-plastic strain curve obtained by using such a specimen is representative of the true material behavior

  19. Population-based Neisseria gonorrhoeae, Chlamydia trachomatis and Trichomonas vaginalis Prevalence Using Discarded, Deidentified Urine Specimens Previously Collected for Drug Testing (Open Access Publisher’s Version)

    Science.gov (United States)

    2017-10-24

    trichomonas vaginalis testing, Melinda Balansay-ames, chris Myers and gary Brice for Pcr- based sex determination testing, and Kimberly De Vera for...2017-053355 rEFErEnCEs 1 torrone e , Papp J, Weinstock H. centers for Disease control and Prevention (cDc). Prevalence of Chlamydia trachomatis genital...infection among persons aged 14-39 years-United States, 2007-2012. MMWR Morb Mortal Wkly Rep 2014;63:834–7. 2 rietmeijer ca, Hopkins e , geisler WM

  20. Fabrication and mechanical test data for the four 6-inch-thick intermediate test vessels made from steel plate for the Heavy Section Steel Program

    International Nuclear Information System (INIS)

    Childress, C.E.

    1976-01-01

    The HSST Program has among its goals the objective of demonstrating the capability to predict safe behavior of thick-walled pressure vessels containing flaws of known dimensions under frangible, transitional, and tough loading regimes. To accomplish these objectives the program is conducting a series of tests involving 6-in.-thick pressure vessels which will serve as test specimens for assisting in the characterization of failure under these loading conditions. Among the vessels a number of parameters, such as weld type, weld location, flaw size and shape, and test temperature and pressure, will be selectively varied to show that a rationale exists for dealing with the varied stress and metallurgical states which normally exist in commercial nuclear reactor vessels. Each vessel will serve as a go, no-go determination of critical flaw size for a specific set of test parameters. Item 4 of the previous issues in this series covers the fabrication details of the first six 6-in.-thick test vessels, which were fabricated from ASTM A-508 Cl 2 forging materials. This report covers the fabrication details of four additional 6-in.-thick intermediate test vessels having shell courses fabricated from ASTM A-533 Gr B Cl 1 plate. The remaining components were made from forgings. Essentially this report is a continuation of ORNL-TM-4351; it describes the manufacturing details of the individual parts and their ultimate assembly into finished vessels. Details concerning chemical composition and mechanical and nondestructive test data are presented

  1. Crashworthiness Analysis and Evaluation of Fuselage Section with Sub-floor Composite Sinusoidal Specimens

    Directory of Open Access Journals (Sweden)

    H.L. Mou

    Full Text Available Abstract Crashworthiness is one of the main concerns in civil aviation safety particularly with regard to the increasing ratio of carbon fiber reinforced plastic (CFRP in aircraft primary structures. In order to generate dates for model validations, the mechanical properties of T700/3234 were obtained by material performance tests, and energy-absorbing results were gained by quasi-static crushing tests of composite sinusoidal specimens. The correctness of composite material model and single-layer finite element model of composite sinusoidal specimens were verified based on the simulation results and test results that were in good agreement. A typical civil aircraft fuselage section with composite sinusoidal specimens under cargo floor was suggested. The crashworthiness of finite element model of fuselage section was assessed by simulating the vertical drop test subjected to 7 m/s impact velocity, and the influences of different thickness of sub-floor composite sinusoidal specimens on crashworthiness of fuselage section were also analyzed. The simulation results show that the established finite element model can accurately simulate the crushing process of composite sinusoidal specimens; the failure process of fuselage section is more stable, and the safety of occupants can be effectively improved because of the smaller peak accelerations that was limited to human tolerance, a critical thickness of sub-floor composite sinusoidal specimens can restrict the magnitude of acceleration peaks, which has certain reference values for enhancing crashworthiness capabilities of fuselage section and improving the survivability of passengers.

  2. Reconstructing a nonlinear dynamical framework for testing quantum mechanics

    International Nuclear Information System (INIS)

    Jordan, T.F.

    1993-01-01

    The nonlinear generalization of quantum dynamics constructed by Weinberg as a basis for experimental tests is reconstructed in terms of density-matrix elements to allow independent dynamics for subsystems. Dynamics is generated with a Lie bracket and a nonlinear Hamiltonian function. It takes density matrices to density matrices and pure states to pure states. Each density matrix has a Hamiltonian operator that makes its evolution for an infinitesimal time, but the Hamiltonian operator may be different for different density matrices and may change in time as the density matrix changes. A Hamiltonian function for a subsystem serves also for the entire system. Independence of separate subsystems is confirmed by seeing that brackets are zero for functions from different subsystems and by looking at the Hamiltonian operator for each density matrix. Scaling properties of Hamiltonian functions are found to be important in connection with locality. An example of all this is obtained from every one of the local nonlinear Schroedinger equations described by Bialynicki-Birula and Mycielski. Examples are worked out for spins coupled together or to fields, demonstrating Hamiltonian functions and equations of motion written directly in terms of physical mean values. Observables and states are taken to be the same as in ordinary quantum mechanics. An attempt to find nonlinear representations of observables by characterizing propositions as functions equal to their squares yields a negative result. Sharper interpretation of mixed states is proposed. In a mixture of parts that are prepared separately, time dependence must be calculated separately for each part so different mixtures that yield the same density matrix can be distinguished. No criticism has shown that a consistent interpretation cannot be made this way. Thus, nonlinearity remains a viable hypothesis for experimental tests. 16 refs

  3. The quantification of specimen size effects in the ductile-brittle transition for C-Mn steel

    International Nuclear Information System (INIS)

    Knee, N.; Worthington, P.J.; Moskovic, R.

    1989-02-01

    It is now generally accepted that the temperature range of the brittle to ductile transition, determined using fracture mechanics specimens, is dependent of the specimen size for ferritic steels. This size effect arises through increasing constraint at the crack tip as the specimen thickness increases together with an increasing volume of material sampled. The size effect can be quantified in terms of a shift in temperature for a given toughness level. This was determined in the present work from fracture toughness/temperature curves obtained by performing fracture toughness tests on eight 100 mm thick compact tension specimens and 40 25 mm thick compact tension specimens over the ductile-brittle transition range of a C-Mn steel. The emphasis is on the development of a practical methodology to quantify the size effect from a limited but still appreciable number of tests. (author)

  4. Fracture Mechanics Testing of Titanium 6AL-4V in AF-M315E

    Science.gov (United States)

    Sampson, J. W.; Martinez, J.; McLean, C.

    2016-01-01

    The Green Propellant Infusion Mission (GPIM) will demonstrate the performance of AF-M315E monopropellant on orbit. Flight certification requires a safe-life analysis of the titanium alloy fuel tank to ensure inherent processing flaws will not cause failure during the design life of the tank. Material property inputs for this analysis require testing to determine the stress intensity factor for environment-assisted cracking (KEAC) of Ti 6Al-4V in combination with the AF-M315E monopropellant. Testing of single-edge notched, or SE(B), specimens representing the bulk tank membrane and weld material were performed in accordance with ASTM E1681. Specimens with fatigue pre-cracks were loaded into test fixtures so that the crack tips were expose