WorldWideScience

Sample records for measured peak values

  1. Converter for Measurement of non-sinusoidal current peak value

    DEFF Research Database (Denmark)

    Butvin, P.; Nielsen, Otto V; Brauer, Peter

    1997-01-01

    A linear-response toroid with core wound of rapidly quenched soft magnetic metallic ribbon and fitted with two windings is used to enable correct measurement of mean peak value of non-sinusoidal and not noise-free alternating current.......A linear-response toroid with core wound of rapidly quenched soft magnetic metallic ribbon and fitted with two windings is used to enable correct measurement of mean peak value of non-sinusoidal and not noise-free alternating current....

  2. Ultrasonic Transducer Peak-to-Peak Optical Measurement

    Directory of Open Access Journals (Sweden)

    Pavel Skarvada

    2012-01-01

    Full Text Available Possible optical setups for measurement of the peak-to-peak value of an ultrasonic transducer are described in this work. The Michelson interferometer with the calibrated nanopositioner in reference path and laser Doppler vibrometer were used for the basic measurement of vibration displacement. Langevin type of ultrasonic transducer is used for the purposes of Electro-Ultrasonic Nonlinear Spectroscopy (EUNS. Parameters of produced mechanical vibration have to been well known for EUNS. Moreover, a monitoring of mechanical vibration frequency shift with a mass load and sample-transducer coupling is important for EUNS measurement.

  3. Reference values of fetal peak systolic blood flow Velocity in the ...

    African Journals Online (AJOL)

    Objectives: The objectives of this prospective cross sectional study are (i) to establish new reference values of peak systolic blood flow velocity measurement in the fetal middle cerebral artery (MCA-PSV) following validated methodological guidelines (ii) to correlate peak systolic velocity with gestational age and (iii) to ...

  4. Changes in Peak Flow Value during Immunotherapy Administration

    International Nuclear Information System (INIS)

    Saporta, D.

    2012-01-01

    Nasal allergies are prevalent affecting a large percentage of the population. Not only the upper respiratory tract but the whole body is involved. Allergies produce morbidity (and even occasional mortality) as they can lead to asthma development, and increased number of accidents. Immunotherapy results can be evaluated by following symptom scores, medication use, and objective measurements. Using a Peak Flow Meter (Pf) to evaluate immunotherapy results, it became evident that patients with and without asthma exhibited an improvement in the Peak Flow (PF) value, suggesting that lower airway involvement in allergic patients could be more prevalent than assumed. A consecutive chart review was performed including patients of any age with nasal allergies (with or without asthma) treated with immunotherapy for at least 6 months that had at least 2 complete evaluations. When immunotherapy was successful, most patients exhibited an increase in the PF value regardless of asthma status. A very significant finding was that most allergy sufferers may have lower airway inflammation. The use of the PF value to assess immunotherapy results and the potential failure to diagnose asthma in allergy sufferers are discussed. A better diagnosis of lower airway inflammation could be substantial in the management of these patients pulmonary function

  5. Accuracy of portable devices in measuring peak cough flow

    International Nuclear Information System (INIS)

    Kulnik, Stefan Tino; Kalra, Lalit; MacBean, Victoria; Birring, Surinder Singh; Moxham, John; Rafferty, Gerrard Francis

    2015-01-01

    Peak cough flow (PCF) measurements can be used as indicators of cough effectiveness. Portable peak flow meters and spirometers have been used to measure PCF, but little is known about their accuracy compared to pneumotachograph systems. The aim of this study was to compare the accuracy of four portable devices (Mini–Wright and Assess peak flow meters, SpiroUSB and Microlab spirometers) in measuring PCF with a calibrated laboratory based pneumotachograph system. Twenty healthy volunteers (mean (SD) age 45 (16) years) coughed through a pneumotachograph connected in series with each portable device in turn, and the differences in PCF readings were analysed. In addition, mechanically generated flow waves of constant peak flow were delivered through each device both independently and when connected in series with the pneumotachograph. Agreement between PCF readings obtained with the pneumotachograph and the portable devices was poor. Peak flow readings were on average lower by approximately 50 L min −1 when measured using the portable devices; 95% limits of agreement spanned approximately 150 L min −1 . The findings highlight the potential for inaccuracy when using portable devices for the measurement of PCF. Depending on the measurement instrument used, absolute values of PCF reported in the literature may not be directly comparable. (paper)

  6. Filtration influence in a constant potential X-ray machine peak voltage measurements

    Energy Technology Data Exchange (ETDEWEB)

    Santos, L.R.; Vivolo, V.; Xavier, M.; Potiens, M.P.A. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Navarro, M.V.T., E-mail: dossantos.lucasrodrigues@gmail.com [Instituto Federal de Educacao, Ciencia e Tecnologia da Bahia (IFBA), Salvador (Brazil)

    2017-09-01

    This work shows the peak voltage measurements for several beam filtrations used in diagnostic radiology, using two types of non-invasive detectors; a voltage meter and a high-resolution spectrometer. The technique chosen for the voltage peak measurements with the spectrometer was the endpoint. The results were compared to the measured ones and showed good similarity to the nominal values. However the voltage meter detector used in this work presented errors for heavier filtrations. (author)

  7. The influence of the maximal value and peak enhancement value of arterial and venous enhancement curve on CT perfusion parameters and signal-to-noise ratio

    International Nuclear Information System (INIS)

    Ju Haiyue; Gao Sijia; Xu Ke; Wang Qiang

    2007-01-01

    Objective: To explore the influence of the maximal value and peak enhancement value of arterial and venous enhancement curve on CT perfusion parameters and signal-to-noise ratio (SNR). Methods: Seventeen patients underwent brain CT perfusion scanning. All row data were analyzed with perfusion software for 6 times, and get different arterial and venous enhancement curves for each patient. The maximal values and peak enhancement values of each arterial and venous enhancement curves, as well as mean perfusion parameters including cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT), permeability surface area product (PS), and their standard deviations (SD) in homolateral white and gray matter were measured and recorded. SNR was calculated by dividing the mean perfusion parameter value by its SD. Pearson correlation analysis and two-tailed paired Student t test were used for statistics. Results: The maximal values and peak enhancement values of arterial and venous curves were correlated with mean SNR CBF , SNR CBV and SNR MTT in both white matter and gray matters (r value range: 0.332-0.922, P PS in white matter(r=0.256, P PS (in both white matter and gray matters) and arterial peak enhancement values, the maximal values and venous peak enhancement values, or between SNR PS (in gray matter) and the maximal values of venous curve(r value range: -0.058-0.210, P>0.05). (2) Mean CBF, CBV and PS values in the group with low venous peak enhancement values were significantly different from the group with high venous peak enhancement values in both white and gray matters (t value range: 3.830-5.337, P 0.05). Conclusions: The mean perfusion parameters and SNR are influenced by the maximal values and peak enhancement values of the arterial and venous curves. Peak enhancement of arterial and venous curves should be adjusted to higher level to make parameter values more reliable and increase the SNR. (authors)

  8. Determination of the diagnostic x-ray tube practical peak voltage (PPV) from average or average peak voltage measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hourdakis, C J, E-mail: khour@gaec.gr [Ionizing Radiation Calibration Laboratory-Greek Atomic Energy Commission, PO Box 60092, 15310 Agia Paraskevi, Athens, Attiki (Greece)

    2011-04-07

    The practical peak voltage (PPV) has been adopted as the reference measuring quantity for the x-ray tube voltage. However, the majority of commercial kV-meter models measure the average peak, U-bar{sub P}, the average, U-bar, the effective, U{sub eff} or the maximum peak, U{sub P} tube voltage. This work proposed a method for determination of the PPV from measurements with a kV-meter that measures the average U-bar or the average peak, U-bar{sub p} voltage. The kV-meter reading can be converted to the PPV by applying appropriate calibration coefficients and conversion factors. The average peak k{sub PPV,kVp} and the average k{sub PPV,Uav} conversion factors were calculated from virtual voltage waveforms for conventional diagnostic radiology (50-150 kV) and mammography (22-35 kV) tube voltages and for voltage ripples from 0% to 100%. Regression equation and coefficients provide the appropriate conversion factors at any given tube voltage and ripple. The influence of voltage waveform irregularities, like 'spikes' and pulse amplitude variations, on the conversion factors was investigated and discussed. The proposed method and the conversion factors were tested using six commercial kV-meters at several x-ray units. The deviations between the reference and the calculated - according to the proposed method - PPV values were less than 2%. Practical aspects on the voltage ripple measurement were addressed and discussed. The proposed method provides a rigorous base to determine the PPV with kV-meters from U-bar{sub p} and U-bar measurement. Users can benefit, since all kV-meters, irrespective of their measuring quantity, can be used to determine the PPV, complying with the IEC standard requirements.

  9. Peak power factor determination of the RA-6 Argentinean Research Reactor using measurement-calculations correlations

    International Nuclear Information System (INIS)

    Sanchez, F. A.; Blaumann, H.; Lopasso, E.; Longhino, J

    2009-01-01

    The maximum power of a reactor is limited by the power peaking factor. During the design stage it is calculated with neutronic calculation codes. This is not enough for ensuring its value due to modelling approximations. For the RA-6s low enrichment new core a calculus-measurement correlation method have been applied. Position and magnitude of the maximum power density estimated by calculus are used by this method. For this work 249 cooper-gold alloy (1.55% Au) wires have been distributed along the core using 19 aluminium blades. Their positions have been selected using information given by a 5 groups PUMA reactor model. Wire s activity have been measured with a HPGe detector. Gold activity have been used only for verifying the calculated core spectrum. The measured power peaking factor was 2.48±0.3 (3σ), 15% above the calculated value. About 97% of measured points had less than 20% calculation-measurement difference and about 80% had less than 10%. The power peaking factor determined by this method consolidates also the calculations models. [es

  10. Quantifying the cepstral peak prominence, a measure of dysphonia.

    Science.gov (United States)

    Heman-Ackah, Yolanda D; Sataloff, Robert T; Laureyns, Griet; Lurie, Deborah; Michael, Deirdre D; Heuer, Reinhardt; Rubin, Adam; Eller, Robert; Chandran, Swapna; Abaza, Mona; Lyons, Karen; Divi, Venu; Lott, Joanna; Johnson, Jennifer; Hillenbrand, James

    2014-11-01

    The purpose of this study is to establish normative values for the smoothed cepstral peak prominence (CPPS) and its sensitivity and specificity as a measure of dysphonia. Prospective cohort study. Voice samples of running speech were obtained from 835 patients and 50 volunteers. Eight laryngologists and four speech-language pathologists performed perceptual ratings of the voice samples on the degree of dysphonia/normality using an analog scale. The mean of their perceptual ratings was used as the gold standard for the detection of the presence or absence of dysphonia. CPPS was measured using the CPPS algorithm of Hillenbrand, and the cut-off value for positivity that has the highest sensitivity and specificity for discriminating between normal and severely dysphonia voices was determined based on ROC-curve analysis. The cut-off value for normal for CPPS was set at 4.0 or higher, which gave a sensitivity of 92.4%, a specificity of 79%, a positive predictive value of 82.5%, and a negative predictive value of 90.8%. The area under the receiver operating characteristic (ROC) curve was 0.937 (P dysphonia, with the normal value of CPPS (Hillenbrand algorithm) of a running speech sample being defined as a value of 4.0 or higher. Copyright © 2014 The Voice Foundation. All rights reserved.

  11. Online junction temperature measurement using peak gate current

    DEFF Research Database (Denmark)

    Baker, Nick; Munk-Nielsen, Stig; Iannuzzo, Francesco

    2015-01-01

    A new method for junction temperature measurement of MOS-gated power semiconductor switches is presented. The measurement method involves detecting the peak voltage over the external gate resistor of an IGBT or MOSFET during turn-on. This voltage is directly proportional to the peak gate current...

  12. Using Energy Peaks to Measure New Particle Masses

    CERN Document Server

    Agashe, Kaustubh; Kim, Doojin

    2014-01-01

    We discussed in arXiv:1209.0772 that the laboratory frame distribution of the energy of a massless particle from a two-body decay at a hadron collider has a peak whose location is identical to the value of this daughter's (fixed) energy in the rest frame of the corresponding mother particle. For that result to hold we assumed that the mother is unpolarized and has a generic boost distribution in the laboratory frame. In this work we discuss how this observation can be applied for determination of masses of new particles, without requiring a full reconstruction of their decay chains or information about the rest of the event. We focus on a two-step cascade decay of a massive particle that has one invisible particle in the final state: C -> Bb -> Aab, where C, B and A are new particles of which A is invisible and a, b are visible particles. Combining the measurements of the peaks of energy distributions of a and b with that of the edge in their invariant mass distribution, we demonstrate that it is in principle...

  13. Peaking-factor of PWR

    International Nuclear Information System (INIS)

    Morioka, Noboru; Kato, Yasuji; Yokoi, M.

    1975-01-01

    Output peaking factor often plays an important role in the safety and operation of nuclear reactors. The meaning of the peaking factor of PWRs is categorized into two features or the peaking factor in core (FQ-core) and the peaking factor on the basis of accident analysis (or FQ-limit). FQ-core is the actual peaking factor realized in nuclear core at the time of normal operation, and FQ-limit should be evaluated from loss of coolant accident and other abnormal conditions. If FQ-core is lower than FQ-limit, the reactor may be operated at full load, but if FQ-core is larger than FQ-limit, reactor output should be controlled lower than FQ-limit. FQ-core has two kinds of values, or the one on the basis of nuclear design, and the other actually measured in reactor operation. The first FQ-core should be named as FQ-core-design and the latter as FQ-core-measured. The numerical evaluation of FQ-core-design is as follows; FQ-core-design of three-dimensions is synthesized with FQ-core horizontal value (X-Y) and FQ-core vertical value, the former one is calculated with ASSY-CORE code, and the latter one with one dimensional diffusion code. For the evaluation of FQ-core-measured, on-site data observation from nuclear reactor instrumentation or off-site data observation is used. (Iwase, T.)

  14. Correlation between peak and median blocking temperatures by magnetization measurement on isolated ferromagnetic and antiferromagnetic particle systems

    DEFF Research Database (Denmark)

    Jiang, Jianzhong; Mørup, Steen

    1997-01-01

    The influence of the particle size distribution on the ratio of the peak temperature, T-peak, to the blocking temperature, T-Bm, in zero field cooled (ZFD) magnetization curves has studied for both ferromagnetic and antiferromagnetic particle systems. In both systems the ratio beta=T-peak/T-Bm does...... not depend on the median particle volume. However, T-Bm can be considerably different from T-peak in both systems. These results show that the ZFD measurements can be used to determine T-Bm values only if the particle size distribution of the system is known. Otherwise, the estimated T-Bm values will have...... a large uncertainty, especially in systems with a broad particle size distribution....

  15. Effects of equipment and technique on peak flow measurements

    Directory of Open Access Journals (Sweden)

    O'Driscoll B Ronan

    2006-06-01

    Full Text Available Abstract Background Different lung function equipment and different respiratory manoeuvres may produce different Peak Expiratory Flow (PEF results. Although the PEF is the most common lung function test, there have been few studies of these effects and no previous study has evaluated both factors in a single group of patients. Methods We studied 36 subjects (PEF range 80–570 l/min. All patients recorded PEF measurements using a short rapid expiration following maximal inspiration (PEF technique or a forced maximal expiration to residual volume (FVC technique. Measurements were made using a Wright's peak flow meter, a turbine spirometer and a Fleisch pneumotachograph spirometer. Results The mean PEF was 8.7% higher when the PEF technique was used (compared with FVC technique, p Conclusion Peak flow measurements are affected by the instruction given and by the device and Peak Flow scale used. Patient management decisions should not be based on PEF measurement made on different instruments.

  16. MEASURING PRIMORDIAL NON-GAUSSIANITY THROUGH WEAK-LENSING PEAK COUNTS

    International Nuclear Information System (INIS)

    Marian, Laura; Hilbert, Stefan; Smith, Robert E.; Schneider, Peter; Desjacques, Vincent

    2011-01-01

    We explore the possibility of detecting primordial non-Gaussianity of the local type using weak-lensing peak counts. We measure the peak abundance in sets of simulated weak-lensing maps corresponding to three models f NL = 0, - 100, and 100. Using survey specifications similar to those of EUCLID and without assuming any knowledge of the lens and source redshifts, we find the peak functions of the non-Gaussian models with f NL = ±100 to differ by up to 15% from the Gaussian peak function at the high-mass end. For the assumed survey parameters, the probability of fitting an f NL = 0 peak function to the f NL = ±100 peak functions is less than 0.1%. Assuming the other cosmological parameters are known, f NL can be measured with an error Δf NL ∼ 13. It is therefore possible that future weak-lensing surveys like EUCLID and LSST may detect primordial non-Gaussianity from the abundance of peak counts, and provide information complementary to that obtained from the cosmic microwave background.

  17. Reference values for peak flow and FEV1 variation in healthy schoolchildren using home spirometry

    NARCIS (Netherlands)

    Brouwer, A. F. J.; Duiverman, E. J.; Brand, P. L. P.

    2008-01-01

    Current reference values for diurnal peak flow variation in healthy children (median 8.2%; 95th percentile 31%) are so high that considerable overlap exists with those of asthmatic children. These values have been obtained using written peak flow diaries, which are unreliable. The aim of the present

  18. Random walkers with extreme value memory: modelling the peak-end rule

    Science.gov (United States)

    Harris, Rosemary J.

    2015-05-01

    Motivated by the psychological literature on the ‘peak-end rule’ for remembered experience, we perform an analysis within a random walk framework of a discrete choice model where agents’ future choices depend on the peak memory of their past experiences. In particular, we use this approach to investigate whether increased noise/disruption always leads to more switching between decisions. Here extreme value theory illuminates different classes of dynamics indicating that the long-time behaviour is dependent on the scale used for reflection; this could have implications, for example, in questionnaire design.

  19. Validity of peak expiratory flow measurement in assessing reversibility of airflow obstruction.

    Science.gov (United States)

    Dekker, F W; Schrier, A C; Sterk, P J; Dijkman, J H

    1992-01-01

    BACKGROUND: Assessing the reversibility of airflow obstruction by peak expiratory (PEF) measurements would be practicable in general practice, but its usefulness has not been investigated. METHODS: PEF measurements were performed (miniWright peak flow meter) in 73 general practice patients (aged 40 to 84) with a history of asthma or chronic obstructive lung disease before and after 400 micrograms inhaled sulbutamol. The change in PEF was compared with the change in forced expiratory volume in one second (FEV1). Reversible airflow obstruction was analysed in two ways according to previous criteria. When defined as a 9% or greater increase in FEV1 expressed as a percentage of predicted values reversibility was observed in 42% of patients. Relative operating characteristic analysis showed that an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (the sensitivity and specificity of an increase of 60 l/min in detecting a 9% or more increase in FEV1 as a percentage of predicted values were 68% and 93% respectively, with a positive predictive value of 87%). When defined as an increase of 190 ml or more in FEV1, reversible airflow obstruction was observed in 53% of patients. Again an absolute improvement in PEF of 60 l/min or more gave optimal discrimination between patients with reversible and irreversible airflow obstruction (sensitivity 56%, specificity 94%, and positive predictive value 92%). CONCLUSION: Absolute changes in PEF can be used as a simple technique to diagnose reversible airflow obstruction in patients from general practice. PMID:1519192

  20. Effects of nonlinear error correction of measurements obtained by peak flowmeter using the Wright scale to assess asthma attack severity in children

    Directory of Open Access Journals (Sweden)

    Stamatović Dragana

    2007-01-01

    Full Text Available Introduction: Monitoring of peak expiratory flow (PEF is recommended in numerous guidelines for management of asthma. Improvements in calibration methods have demonstrated the inaccuracy of original Wright scale of peak flowmeter. A new standard, EN 13826 that was applied to peak flowmeter was adopted on 1st September 2004 by some European countries. Correction of PEF readings obtained with old type devices for measurement is possible by Dr M. Miller’s original predictive equation. Objective. Assessment of PEF correction effect on the interpretation of measurement results and management decisions. Method. In children with intermittent (35 or stable persistent asthma (75 aged 6-16 years, there were performed 8393 measurements of PEF by Vitalograph normal-range peak flowmeter with traditional Wright scale. Readings were expressed as percentage of individual best values (PB before and after correction. The effect of correction was analyzed based on The British Thoracic Society guidelines for asthma attack treatment. Results. In general, correction reduced the values of PEF (p<0.01. The highest mean percentage error (20.70% in the measured values was found in the subgroup in which PB ranged between 250 and 350 l/min. Nevertheless, the interpretation of PEF after the correction in this subgroup changed in only 2.41% of measurements. The lowest mean percentage error (15.72%, and, at the same time, the highest effect of correction on measurement results interpretation (in 22.65% readings were in children with PB above 450 l/min. In 73 (66.37% subjects, the correction changed the clinical interpretation of some values of PEF after correction. In 13 (11.8% patients, some corrected values indicated the absence or a milder degree of airflow obstruction. In 27 (24.54% children, more than 10%, and in 12 (10.93%, more than 20% of the corrected readings indicated a severe degree of asthma exacerbation that needed more aggressive treatment. Conclusion

  1. The dislocation-internal friction peak γ in tantalum

    International Nuclear Information System (INIS)

    Baur, J.; Benoit, W.; Schultz, H.

    1989-01-01

    Torsion-pendulum measurements were carried out on high-purity single crystal specimens of tantalum, having extremely low oxygen contents ( 2 peak, which appears close to γ is small traces of oxygen are presents. The γ 2 peak was formerly explained as a ''dislocation-enhanced Snoek peak''. The γ peak recovers at the peak temperature, whereas the γ 2 peak is more stable. On the basis of their results, and making use of earlier investigations of Rodrian and Schultz, the authors suggest that γ 2 is modified γ relaxation, related to screw-dislocation segments, stabilized by oxygen-decorated kinks. The stability of the γ 2 peak allows an accurate determination of the activation energy, found to be 1.00 +- 0.03 eV. This value is distinctly lower than the activation energy of the oxygen Snoek effect (1.10 eV) and is related here to the mechanism of ''kink-pair formation'' in screw dislocations, as the original γ peak. The numerical value is compatible with recent values derived from flow-stress measurements. The peak γ 2 shows increasing stability with increasing oxygen content. This is explained by single- and multi-decorated kinks

  2. Assessing peak aerobic capacity in Dutch law enforcement officers

    Directory of Open Access Journals (Sweden)

    Harriet Wittink

    2015-06-01

    Full Text Available Objectives: To cross-validate the existing peak rate of oxygen consumption (VO2peak prediction equations in Dutch law enforcement officers and to determine whether these prediction equations can be used to predict VO2peak for groups and in a single individual. A further objective was to report normative absolute and relative VO2peak values of a sample of law enforcement officers in the Netherlands. Material and Methods: The peak rate of oxygen consumption (ml×kg–1×min–1 was measured using a maximal incremental bicycle test in 1530 subjects, including 1068 male and 461 female police officers. Validity of the prediction equations for groups was assessed by comparing predicted VO2peak with measured VO2peak using paired t-tests. For individual differences limits of agreement (LoA were calculated. Equations were considered valid for individuals when the difference between measured and predicted VO2peak did not exceed ±1 metabolic equivalent (MET in 95% of individuals. Results: None of the equations met the validity criterion of 95% of individuals having ±1 MET difference or less than the measured value. Limits of agreement (LoAs were large in all predictions. At the individual level, none of the equations were valid predictors of VO2peak (ml×kg–1×min–1. Normative values for Dutch law enforcement officers were presented. Conclusions: Substantial differences between measured and predicted VO2peak (ml×kg–1×min–1 were found. Most tested equations were invalid predictors of VO2peak at group level and all were invalid at individual levels.

  3. Pediatric Exercise Testing: Value and Implications of Peak Oxygen Uptake

    Directory of Open Access Journals (Sweden)

    Paolo T. Pianosi

    2017-01-01

    Full Text Available Peak oxygen uptake (peak V ˙ O 2 measured by clinical exercise testing is the benchmark for aerobic fitness. Aerobic fitness, estimated from maximal treadmill exercise, is a predictor of mortality in adults. Peak V ˙ O 2 was shown to predict longevity in patients aged 7–35 years with cystic fibrosis over 25 years ago. A surge of exercise studies in young adults with congenital heart disease over the past decade has revealed significant prognostic information. Three years ago, the first clinical trial in children with pulmonary arterial hypertension used peak V ˙ O 2 as an endpoint that likewise delivered clinically relevant data. Cardiopulmonary exercise testing provides clinicians with biomarkers and clinical outcomes, and researchers with novel insights into fundamental biological mechanisms reflecting an integrated physiological response hidden at rest. Momentum from these pioneering observations in multiple disease states should impel clinicians to employ similar methods in other patient populations; e.g., sickle cell disease. Advances in pediatric exercise science will elucidate new pathways that may identify novel biomarkers. Our initial aim of this essay is to highlight the clinical relevance of exercise testing to determine peak V ˙ O 2 , and thereby convince clinicians of its merit, stimulating future clinical investigators to broaden the application of exercise testing in pediatrics.

  4. Measuring saccade peak velocity using a low-frequency sampling rate of 50 Hz.

    Science.gov (United States)

    Wierts, Roel; Janssen, Maurice J A; Kingma, Herman

    2008-12-01

    During the last decades, small head-mounted video eye trackers have been developed in order to record eye movements. Real-time systems-with a low sampling frequency of 50/60 Hz-are used for clinical vestibular practice, but are generally considered not to be suited for measuring fast eye movements. In this paper, it is shown that saccadic eye movements, having an amplitude of at least 5 degrees, can, in good approximation, be considered to be bandwidth limited up to a frequency of 25-30 Hz. Using the Nyquist theorem to reconstruct saccadic eye movement signals at higher temporal resolutions, it is shown that accurate values for saccade peak velocities, recorded at 50 Hz, can be obtained, but saccade peak accelerations and decelerations cannot. In conclusion, video eye trackers sampling at 50/60 Hz are appropriate for detecting the clinical relevant saccade peak velocities in contrast to what has been stated up till now.

  5. Appendicular Skeletal Muscle Mass Reference Values and the Peak Muscle Mass to Identify Sarcopenia among Iranian Healthy Population.

    Science.gov (United States)

    Shafiee, Gita; Ostovar, Afshin; Heshmat, Ramin; Keshtkar, Abbas Ali; Sharifi, Farshad; Shadman, Zhaleh; Nabipour, Iraj; Soltani, Akbar; Larijani, Bagher

    2018-01-01

    Sacopenia is a common problem in elderly with the adverse outcomes. The objective of this study was to estimate the peak appendicular skeletal muscle mass (ASM) and age of its attainment by sex among the Iranian population. A total of 691 men and women aged 18-94 years participated in this cross-sectional, population-based study in Bushehr, Iran. ASM was measured by dual X-ray absorptiometry. Cutoff points for men and women were established considering two standard deviations (SDs) below the mean values of the skeletal muscle index (SMI) for young reference groups. The relationship between ASM and age was described by the second-degree regression models. Two SDs below the mean SMIs of reference groups were as cutoff values of low muscle mass in Iranian population. The peak ASM values were 21.35 ± 0.12 Kg and 13.68 ± 0.10 Kg, and the age at peak ASM were 26 (24-28) years and 34 (33-35) years for men and women, respectively. Mean and SD of SMI in those ages were 7.01 ± 0.02 Kg/m 2 and 5.44 ± 0.02 Kg/m 2 among men and women, respectively. Calculated cutoff values of low muscle mass among the Iranian population were 7.0 Kg/m 2 and 5.4 Kg/m 2 among men and women, respectively. Iranian reference values of SMI for both genders were similar to Asia Working Group for Sarcopenia recommendation and lower than the United States and European values. Further studies from different nations and the Middle East countries are needed to obtain reference values for populations, enabling the researchers for comparison and also more valid reports on sarcopenia prevalence.

  6. Prediction of peak response values of structures with and without TMD subjected to random pedestrian flows

    Science.gov (United States)

    Lievens, Klaus; Van Nimmen, Katrien; Lombaert, Geert; De Roeck, Guido; Van den Broeck, Peter

    2016-09-01

    In civil engineering and architecture, the availability of high strength materials and advanced calculation techniques enables the construction of slender footbridges, generally highly sensitive to human-induced excitation. Due to the inherent random character of the human-induced walking load, variability on the pedestrian characteristics must be considered in the response simulation. To assess the vibration serviceability of the footbridge, the statistics of the stochastic dynamic response are evaluated by considering the instantaneous peak responses in a time range. Therefore, a large number of time windows are needed to calculate the mean value and standard deviation of the instantaneous peak values. An alternative method to evaluate the statistics is based on the standard deviation of the response and a characteristic frequency as proposed in wind engineering applications. In this paper, the accuracy of this method is evaluated for human-induced vibrations. The methods are first compared for a group of pedestrians crossing a lightly damped footbridge. Small differences of the instantaneous peak value were found by the method using second order statistics. Afterwards, a TMD tuned to reduce the peak acceleration to a comfort value, was added to the structure. The comparison between both methods in made and the accuracy is verified. It is found that the TMD parameters are tuned sufficiently and good agreements between the two methods are found for the estimation of the instantaneous peak response for a strongly damped structure.

  7. Some practical aspects of peak kilovoltage measurements

    International Nuclear Information System (INIS)

    Irfan, A.Y.; Pugh, V.I.; Jeffery, C.D.

    1985-01-01

    The peak kilovoltage (kVsub(p)) across the X-ray tube electrodes in diagnostic X-ray machines is a most important parameter, affecting both radiation output and beam quality. Four commercially available non-invasive devices used for kVsub(p) measurement were tested using a selection of generator waveforms. The majority of the devices provided satisfactory measurements of the kVsub(p) to within approximately +- kV provided certain operating conditions are observed. (U.K.)

  8. Multiple-valued logic design based on the multiple-peak BiCMOS-NDR circuits

    Directory of Open Access Journals (Sweden)

    Kwang-Jow Gan

    2016-06-01

    Full Text Available Three different multiple-valued logic (MVL designs using the multiple-peak negative-differential-resistance (NDR circuits are investigated. The basic NDR element, which is made of several Si-based metal-oxide-semiconductor field-effect-transistor (MOS and SiGe-based heterojunction-bipolar-transistor (HBT devices, can be implemented by using a standard BiCMOS process. These MVL circuits are designed based on the triggering-pulse control, saw-tooth input signal, and peak-control methods, respectively. However, there are some transient states existing between the multiple stable levels for the first two methods. These states might affect the circuit function in practical application. As a result, our proposed peak-control method for the MVL design can be used to overcome these transient states.

  9. Arm Crank and Wheelchair Ergometry Produce Similar Peak Oxygen Uptake but Different Work Economy Values in Individuals with Spinal Cord Injury

    Directory of Open Access Journals (Sweden)

    Tom Tørhaug

    2016-01-01

    Full Text Available Objective. To study whether values for peak oxygen uptake (VO2peak and work economy (WE at a standardized workload are different when tested by arm crank ergometry (ACE and wheelchair ergometry (WCE. Methods. Twelve paraplegic men with spinal cord injury (SCI in stable neurological condition participated in this cross-sectional repeated-measures study. We determined VO2peak and peak power output (POpeak values during ACE and WCE in a work-matched protocol. Work economy was tested at a standardized workload of 30 Watts (W for both ACE and WCE. Results. There were no significant differences in VO2peak (mL·kg−1·min−1 between ACE (27.3±3.2 and WCE (27.4±3.8 trials, and a Bland-Altman plot shows that findings are within 95% level of agreement. WE or oxygen consumption at 30 W (VO2-30W was significantly lower during WCE compared to ACE (P<0.039. Mean (95% CI POpeak (W were 130 (111–138 and 100 (83–110 during ACE and WCE, respectively. Conclusion. The findings in the present study support the use of both ACE and WCE for testing peak oxygen uptake. However, WE differed between the two test modalities, meaning that less total energy is used to perform external work of 30 W during wheelchair exercise when using this WCE (VP100 Handisport ergometer. Clinical Trials Protocol Record is NCT00987155/4.2007.2271.

  10. Peak reading detector circuit

    International Nuclear Information System (INIS)

    Courtin, E.; Grund, K.; Traub, S.; Zeeb, H.

    1975-01-01

    The peak reading detector circuit serves for picking up the instants during which peaks of a given polarity occur in sequences of signals in which the extreme values, their time intervals, and the curve shape of the signals vary. The signal sequences appear in measuring the foetal heart beat frequence from amplitude-modulated ultrasonic, electrocardiagram, and blood pressure signals. In order to prevent undesired emission of output signals from, e. g., disturbing intermediate extreme values, the circuit consists of the series connections of a circuit to simulate an ideal diode, a strong unit, a discriminator for the direction of charging current, a time-delay circuit, and an electronic switch lying in the decharging circuit of the storage unit. The time-delay circuit thereby causes storing of a preliminary maximum value being used only after a certain time delay for the emission of the output signal. If a larger extreme value occurs during the delay time the preliminary maximum value is cleared and the delay time starts running anew. (DG/PB) [de

  11. Trabecular bone mineral density measured by quantitative CT of the lumbar spine in children and adolescents: reference values and peak bone mass

    International Nuclear Information System (INIS)

    Berthold, L.D.; Alzen, G.; Haras, G.; Mann, M.

    2006-01-01

    Purpose: The aim of this study was to assess bone density values in the trabecular substance of the lumbar vertebral column in children and young adults in Germany from infancy to the age of peak bone mass. Materials and Methods: We performed quantiative computed tomography (QCT) on the first lumbar vertebra in 28 children and adolescents without diseases that may influence bone metabolism (15 boys, 13 girls, mean ages 11 and 8 years, respectively). We also measured 17 healthy young adults (9 men, 8 women, mean ages 20 and 21 years). We used a Somatom Balance Scanner (Siemens, Erlangen) and the Siemens Osteo software. Scan parameters: Slice thickness 1 cm, 80 kV, 81 or 114 mAs. We measured the trabecular bone density and the area and height of the vertebra and calculated the volume and content of calcium hydroxyapatite (Ca-HA) in the trabecular substance of the first lumbar vertebra. Results: Prepubertal boys had a mean bone density of 148.5 (median [med] 150.1, standard deviation [SD] 15.4) mg/Ca-HA per ml bone, and prepubertal girls had a mean density of 149.5 (med 150.8, SD 23.5) mg/ml. We did not observe a difference between prepubertal boys and girls. After puberty there was a significant difference (p<0.001) between males and females: Mean density (male) 158.0, med 162.5, SD 24.0 mg/ml, mean density (female) 191.2, med 191.3, SD 17.7 mg/ml. The Ca-HA content in the trabecular bone of the first lumbar vertebra was 1.1 (med 1.1, SD 0.5) g for prepubertal boys and 1.1 (0.9, 0.4) g for prepubertal girls. For post-pubertal males, the mean Ca-HA content was 3.5 g, med 3.5 SD 0.5 g, and for post-pubertal females, the mean content was 2.8, med 2.7, SD 0.4 g. Conclusion: The normal trabecular bone mineral density is 150 mg/ml with a standard deviation of 20 mg/ml independent of age or gender until the beginning of puberty. Peak bone mass (bone mineral content) in the trabecular substance of the lumbar vertebral column is higher in males than in females, and peak bone

  12. Variable threshold method for ECG R-peak detection.

    Science.gov (United States)

    Kew, Hsein-Ping; Jeong, Do-Un

    2011-10-01

    In this paper, a wearable belt-type ECG electrode worn around the chest by measuring the real-time ECG is produced in order to minimize the inconvenient in wearing. ECG signal is detected using a potential instrument system. The measured ECG signal is transmits via an ultra low power consumption wireless data communications unit to personal computer using Zigbee-compatible wireless sensor node. ECG signals carry a lot of clinical information for a cardiologist especially the R-peak detection in ECG. R-peak detection generally uses the threshold value which is fixed. There will be errors in peak detection when the baseline changes due to motion artifacts and signal size changes. Preprocessing process which includes differentiation process and Hilbert transform is used as signal preprocessing algorithm. Thereafter, variable threshold method is used to detect the R-peak which is more accurate and efficient than fixed threshold value method. R-peak detection using MIT-BIH databases and Long Term Real-Time ECG is performed in this research in order to evaluate the performance analysis.

  13. Dual-peak dose measurement for radiochromic films by a newly developed spectral microdensitometer

    International Nuclear Information System (INIS)

    Lee, K.Y.; Fung, K.K.L.; Kwok, C.S.

    2005-01-01

    Radiochromic film (RCF) dosimetry is usually based on densitometric methods which use an analyzing light source of a fixed or a broad spectrum of wavelengths. These methods have not exploited the sensitivity of the dose response of the RCF otherwise attainable by using a light source with wavelengths peaked at the two absorption peaks in the absorption spectrum of the RCF. A new algorithm of dual-peak dose measurement for the RCF has been proposed in this paper to make use of these dual absorption peaks to achieve the maximum attainable sensitivity. This technique relies on the measurement of the transmittance of the RCF at the wavelength of the major and minor absorption peaks, respectively. The dual-peak dose measurement is accomplished with the aid of a novel spectral microdensitometer developed in our Institute. The microdensitometer utilizes a monochromator to provide a light source of which the wavelength can be matched precisely to the wavelength of the absorption peaks of the RCF. The doses obtained at these wavelengths are fed into a weighted objective function and an optimum dose is searched by minimizing the objective function to give the best estimate of the dose deposited on the film. An initial test shows that there is a good agreement between the estimated and actual dose deposited; and the maximum discrepancy was found to be less than 1%

  14. Implementation of the Peak Scaling Method for Temperature Measurement in the Laser Heated Diamond Anvil Cell at ALS Beamline 12.2.2

    Science.gov (United States)

    Kunz, M.; MacDowell, A. A.; Yan, J.; Beavers, C.; Doran, A.; Williams, Q. C.

    2016-12-01

    The laser-heated diamond anvil cell (LHDAC) is an important tool in the quest to correlate seismologically derived density and velocity profiles of the Earth with mineralogical models. Precise and accurate measurement of pressure and temperature is crucial for the LHDAC to be useful. Measuring accurate temperatures of laser-heated samples is an ongoing problem. One of the more promising approaches is the `peak-scaling method' as proposed by Kavner and Panero [2004]. This method relies on imaging the entire hot spot, rather than only the peak region onto the grating of a spectrometer. The temperature derived from the entire hotspot is an `average' temperature of the full hot spot. Combined with a monochromatic intensity map of the hot spot and a single temperature spot on this map (normally the peak temperature), a complete temperature map of the LHDAC can be derived. The crux of the method is to determine an accurate peak temperature. Using MATLAB, we derived systematic dependences of the relationship between average temperature and peak temperature as a function of peak temperature, deviations from the grey body assumption [ɛ = f(T,λ)], size and shape of hotspot, as well as the size and position of the spectral window used for spectral fitting. We find these average-to-peak deviations to be significant (5 - 25 %) and hard to control. To avoid biases introduced into the temperature map by erroneous assumptions on the peak temperature, we implemented on ALS beamline 12.2.2 an iterative way to fit a correct peak temperature based on the measured average temperature and measured monochromatic (700 nm) intensity map of the hot spot. The method calculates an average temperature by inverting the Planck equation on the intensities extracted from the monochromatic hotspot image and compares this value to the value obtained by fitting the Wien approximation to the averaged spectrum of the entire hotspot. The peak temperature is adjusted until the difference between

  15. Determination of Component Contents of Blend Oil Based on Characteristics Peak Value Integration.

    Science.gov (United States)

    Xu, Jing; Hou, Pei-guo; Wang, Yu-tian; Pan, Zhao

    2016-01-01

    Edible blend oil market is confused at present. It has some problems such as confusing concepts, randomly named, shoddy and especially the fuzzy standard of compositions and ratios in blend oil. The national standard fails to come on time after eight years. The basic reason is the lack of qualitative and quantitative detection of vegetable oils in blend oil. Edible blend oil is mixed by different vegetable oils according to a certain proportion. Its nutrition is rich. Blend oil is eaten frequently in daily life. Different vegetable oil contains a certain components. The mixed vegetable oil can make full use of their nutrients and make the nutrients more balanced in blend oil. It is conducive to people's health. It is an effectively way to monitor blend oil market by the accurate determination of single vegetable oil content in blend oil. The types of blend oil are known, so we only need for accurate determination of its content. Three dimensional fluorescence spectra are used for the contents in blend oil. A new method of data processing is proposed with calculation of characteristics peak value integration in chosen characteristic area based on Quasi-Monte Carlo method, combined with Neural network method to solve nonlinear equations to obtain single vegetable oil content in blend oil. Peanut oil, soybean oil and sunflower oil are used as research object to reconcile into edible blend oil, with single oil regarded whole, not considered each oil's components. Recovery rates of 10 configurations of edible harmonic oil is measured to verify the validity of the method of characteristics peak value integration. An effective method is provided to detect components content of complex mixture in high sensitivity. Accuracy of recovery rats is increased, compared the common method of solution of linear equations used to detect components content of mixture. It can be used in the testing of kinds and content of edible vegetable oil in blend oil for the food quality detection

  16. Additive prognostic value of interleukin-6 at peak phase of dobutamine stress echocardiography in patients with coronary artery disease. A 6-year follow-up study.

    Science.gov (United States)

    Ikonomidis, Ignatios; Athanassopoulos, George; Stamatelopoulos, Kimon; Lekakis, John; Revela, Ioanna; Venetsanou, Kiriaki; Marinou, Margarita; Monaco, Claudia; Cokkinos, Dennis V; Nihoyannopoulos, Petros

    2008-08-01

    Interleukin-6 (IL-6) and tissue factor (TF) are elevated after myocardial ischemia during dobutamine stress echo (DSE). We examined the incremental prognostic value of IL-6 or TF measured during DSE over echocardiographic and clinical factors in patients with chronic coronary artery disease (CAD). We studied 106 patients with angiographically documented CAD. IL-6 and TF were measured at rest, peak, and during recovery. A wall motion score index was calculated. Fifty-seven (54%) patients had ischemia at DSE. During follow-up (63.7 +/- 20 months), 36 patients (33%) had an adverse event (12 cardiac deaths, 24 acute coronary events). Patients with events had a higher peak IL-6 (P = .02) but similar rest and recovery IL-6 than those without. Patients with peak IL-6 > or =3.14 pg/mL (upper tertile) had a hazard ratio of 2.7 (95% CI 1.44-5.37) (P statistic from 0.66 to 0.70 (P = .04). The addition of peak IL-6 further increased the model's c statistic to 0.75 (P = .04). Tissue factor was not related with cardiac events. Interleuikin-6 levels measured during the peak phase of DSE incrementally contribute to risk stratification in patients with chronic CAD.

  17. Chapter 10: Peak Demand and Time-Differentiated Energy Savings Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

    Energy Technology Data Exchange (ETDEWEB)

    Kurnik, Charles W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Stern, Frank [Navigant, Boulder, CO (United States); Spencer, Justin [Navigant, Boulder, CO (United States)

    2017-10-03

    Savings from electric energy efficiency measures and programs are often expressed in terms of annual energy and presented as kilowatt-hours per year (kWh/year). However, for a full assessment of the value of these savings, it is usually necessary to consider the measure or program's impact on peak demand as well as time-differentiated energy savings. This cross-cutting protocol describes methods for estimating the peak demand and time-differentiated energy impacts of measures implemented through energy efficiency programs.

  18. In vivo dissolution measurement with indium-111 summation peak ratios

    International Nuclear Information System (INIS)

    Jay, M.; Woodward, M.A.; Brouwer, K.R.

    1985-01-01

    Dissolution of [ 111 In]labeled tablets was measured in vivo in a totally noninvasive manner by using a modification of the perturbed angular correlation technique known as the summation peak ratio method. This method, which requires the incorporation of only 10-12 microCi into the dosage form, provided reliable dissolution data after oral administration of [ 111 In]lactose tablets. These results were supported by in vitro experiments which demonstrated that the dissolution rate as measured by the summation peak ratio method was in close agreement with the dissolution rate of salicylic acid in a [ 111 In]salicylic acid tablet. The method has the advantages of using only one detector, thereby avoiding the need for complex coincidence counting systems, requiring less radioactivity, and being potentially applicable to a gamma camera imaging system

  19. Measurements and simulations for peak electrical load reduction in cooling dominated climate

    International Nuclear Information System (INIS)

    Sadineni, Suresh B.; Boehm, Robert F.

    2012-01-01

    Peak electric demand due to cooling load in the Desert Southwest region of the US has been an issue for the electrical energy suppliers. To address this issue, a consortium has been formed between the University of Nevada Las Vegas, Pulte Homes (home builder) and NV Energy (local utility) in order to reduce the peak load by more than 65%. The implemented strategies that were used to accomplish that goal consist of energy efficiency in homes, onsite electricity generation through roof integrated PV, direct load control, and battery storage at the substation level. The simulation models developed using building energy analysis software were validated against measured data. The electrical energy demand for the upgraded home during peak period (1:00–7:00 PM) decreased by approximately 37% and 9% compared to a code standard home of the same size, due to energy efficiency and PV generation, respectively. The total decrease in electrical demand due to energy efficiency and PV generation during the peak period is 46%. Additionally, a 2.2 °C increase in thermostat temperature from 23.9 °C to 26.1 °C between 4:00 PM and 7:00 PM has further decreased the average demand during the peak period by 69% of demand from a standard home. -- Highlights: ► A study to demonstrate peak load reductions of 65% at the substation. ► A new residential energy efficient community named Villa Trieste is being developed. ► The peak demand from the homes has decreased by 37% through energy efficiency. ► A 1.8 kWp system along with energy efficiency measures decreased peak by 46%.

  20. Comparison of five portable peak flow meters.

    Science.gov (United States)

    Takara, Glaucia Nency; Ruas, Gualberto; Pessoa, Bruna Varanda; Jamami, Luciana Kawakami; Di Lorenzo, Valéria Amorim Pires; Jamami, Mauricio

    2010-05-01

    To compare the measurements of spirometric peak expiratory flow (PEF) from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone, Assess, Galemed, Personal Best and Vitalograph peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (pmeters were 428 (263-688 L/min), 450 (350-800 L/min), 420 (310-720 L/min), 380 (300-735 L/min), 400 (310-685 L/min) and 415 (335-610 L/min), respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone(R) (pmeters. There was no agreement between the spirometric values and the five PEF meters. The results suggest that the values recorded from Galemed meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  1. A peak value searching method of the MCA based on digital logic devices

    International Nuclear Information System (INIS)

    Sang Ziru; Huang Shanshan; Chen Lian; Jin Ge

    2010-01-01

    Digital multi-channel analyzers play a more important role in multi-channel pulse height analysis technique. The direction of digitalization are characterized by powerful pulse processing ability, high throughput, improved stability and flexibility. This paper introduces a method of searching peak value of waveform based on digital logic with FPGA. This method reduce the dead time. Then data correction offline can improvement the non-linearity of MCA. It gives the α energy spectrum of 241 Am. (authors)

  2. Measurement of peak discharge at dams by indirect methods

    Science.gov (United States)

    Hulsing, Harry

    1967-01-01

    This chapter describes procedures for measuring peak discharges using dams, weirs, and embankments. Field and office procedures limited to this method are described. Discharge coefficients and formulas are given for three general classes of weirs-sharp-crested, broad-crested, and round-crested-and for highway embankments and weirs of unusual shape. The effects of submergence are defined for most forms.

  3. Operational and structural measures to reduce hydro-peaking impact on fish larvae

    International Nuclear Information System (INIS)

    Kopecki, Ianina; Schneider, Matthias

    2016-01-01

    Eco-hydraulic investigations studying the effects of hydro-peaking on river biota are gaining in importance. Negative effects of rapid flow fluctuations due to hydro power production are well documented by many studies, with the larvae and juvenile fish identified among the mostly affected life stages. Therefore, elaboration of efficient hydro-peaking mitigation strategies is an important issue for energy companies as well as for water body administrations responsible for the fulfilment of WFD requirements. The present case study strives for practical solutions allowing to minimize or compensate the negative effects of hydro-peaking on the fish fauna of the 7 km long river reach on the river Lech (southern Germany). Model based investigations allow to access the impact from currently authorized discharge regime, suggest operational and structural measures within the reach in terms of reducing the risk of stranding for fish larvae and select the measures most easy to implement and with the largest ecological benefit. The paper describes the approach for accessing the effects of hydro-peaking based on 2D hydrodynamic modelling, fuzzy logic based habitat modelling and information on cutting-edge biological investigations on fish larvae from Lunz experimental facility (Austria). (authors)

  4. Detection of Golden apples' climacteric peak by laser biospeckle measurements.

    Science.gov (United States)

    Nassif, Rana; Nader, Christelle Abou; Afif, Charbel; Pellen, Fabrice; Le Brun, Guy; Le Jeune, Bernard; Abboud, Marie

    2014-12-10

    In this paper, we report a study in which a laser biospeckle technique is used to detect the climacteric peak indicating the optimal ripeness of fruits. We monitor two batches of harvested Golden apples going through the ripening phase in low- and room-temperature environments, determine speckle parameters, and measure the emitted ethylene concentration using gas chromatography as reference method. Speckle results are then correlated to the emitted ethylene concentration by a principal component analysis. From a practical point of view, this approach allows us to validate biospeckle as a noninvasive and alternative method to respiration rate and ethylene production for climacteric peak detection as a ripening index.

  5. [A peak recognition algorithm designed for chromatographic peaks of transformer oil].

    Science.gov (United States)

    Ou, Linjun; Cao, Jian

    2014-09-01

    In the field of the chromatographic peak identification of the transformer oil, the traditional first-order derivative requires slope threshold to achieve peak identification. In terms of its shortcomings of low automation and easy distortion, the first-order derivative method was improved by applying the moving average iterative method and the normalized analysis techniques to identify the peaks. Accurate identification of the chromatographic peaks was realized through using multiple iterations of the moving average of signal curves and square wave curves to determine the optimal value of the normalized peak identification parameters, combined with the absolute peak retention times and peak window. The experimental results show that this algorithm can accurately identify the peaks and is not sensitive to the noise, the chromatographic peak width or the peak shape changes. It has strong adaptability to meet the on-site requirements of online monitoring devices of dissolved gases in transformer oil.

  6. Player Monitoring in Indoor Team Sports: Concurrent Validity of Inertial Measurement Units to Quantify Average and Peak Acceleration Values

    Directory of Open Access Journals (Sweden)

    Mareike Roell

    2018-02-01

    Full Text Available The increasing interest in assessing physical demands in team sports has led to the development of multiple sports related monitoring systems. Due to technical limitations, these systems primarily could be applied to outdoor sports, whereas an equivalent indoor locomotion analysis is not established yet. Technological development of inertial measurement units (IMU broadens the possibilities for player monitoring and enables the quantification of locomotor movements in indoor environments. The aim of the current study was to validate an IMU measuring by determining average and peak human acceleration under indoor conditions in team sport specific movements. Data of a single wearable tracking device including an IMU (Optimeye S5, Catapult Sports, Melbourne, Australia were compared to the results of a 3D motion analysis (MA system (Vicon Motion Systems, Oxford, UK during selected standardized movement simulations in an indoor laboratory (n = 56. A low-pass filtering method for gravity correction (LF and two sensor fusion algorithms for orientation estimation [Complementary Filter (CF, Kalman-Filter (KF] were implemented and compared with MA system data. Significant differences (p < 0.05 were found between LF and MA data but not between sensor fusion algorithms and MA. Higher precision and lower relative errors were found for CF (RMSE = 0.05; CV = 2.6% and KF (RMSE = 0.15; CV = 3.8% both compared to the LF method (RMSE = 1.14; CV = 47.6% regarding the magnitude of the resulting vector and strongly emphasize the implementation of orientation estimation to accurately describe human acceleration. Comparing both sensor fusion algorithms, CF revealed slightly lower errors than KF and additionally provided valuable information about positive and negative acceleration values in all three movement planes with moderate to good validity (CV = 3.9 – 17.8%. Compared to x- and y-axis superior results were found for the z-axis. These findings demonstrate that

  7. Time-resolved measurement of emission profiles in pulsed radiofrequency glow discharge optical emission spectroscopy: Investigation of the pre-peak

    International Nuclear Information System (INIS)

    Alberts, D.; Horvath, P.; Nelis, Th.; Pereiro, R.; Bordel, N.; Michler, J.; Sanz-Medel, A.

    2010-01-01

    Radiofrequency glow discharge coupled to optical emission spectroscopy has been used in pulsed mode in order to perform a detailed study of the measured temporal emission profiles for a wide range of copper transitions. Special attention has been paid to the early emission peak (or so-called pre-peak), observed at the beginning of the emission pulse profile. The effects of the important pulse parameters such as frequency, duty cycle, pulse width and power-off time, have been studied upon the Cu pulse emission profiles. The influence of discharge parameters, such as pressure and power, was studied as well. Results have shown that the intensity observed in the pre-peak can be 10 times as large as the plateau value for resonant lines and up to 5 times in case of transitions to the metastable levels. Increasing pressure or power increased the pre-peak intensity while its appearance in time changed. The pre-peak decreased when the discharge off-time was shorter than 100 μs. According to such results, the presence of the pre-peak could be probably due to the lack of self-absorption during the first 50 μs, and not to the ignition of the plasma. Under the selected operation conditions, the use of the pre-peak emission as analytical signals increases the linearity of calibration curves for resonant lines subjected to self-absorption at high concentrations.

  8. Time-resolved measurement of emission profiles in pulsed radiofrequency glow discharge optical emission spectroscopy: Investigation of the pre-peak

    Energy Technology Data Exchange (ETDEWEB)

    Alberts, D. [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Claveria 8, 33006 Oviedo (Spain); Horvath, P. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Feuerwerkerstrasse 39, 3602 Thun (Switzerland); Nelis, Th. [LAPLACE, Universite Paul Sabatier, 118 rte de Narbonne, Bat3R2, 31062 Toulouse Cedex (France); CU Jean Francois Champollion, Place de Verdun 81012 Albi Cedex 9 (France); Pereiro, R. [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Claveria 8, 33006 Oviedo (Spain); Bordel, N. [Department of Physics, Faculty of Science, University of Oviedo, Calvo Sotelo, 33007 Oviedo (Spain); Michler, J. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Feuerwerkerstrasse 39, 3602 Thun (Switzerland); Sanz-Medel, A., E-mail: asm@uniovi.e [Department of Physical and Analytical Chemistry, Faculty of Chemistry, University of Oviedo, Julian Claveria 8, 33006 Oviedo (Spain)

    2010-07-15

    Radiofrequency glow discharge coupled to optical emission spectroscopy has been used in pulsed mode in order to perform a detailed study of the measured temporal emission profiles for a wide range of copper transitions. Special attention has been paid to the early emission peak (or so-called pre-peak), observed at the beginning of the emission pulse profile. The effects of the important pulse parameters such as frequency, duty cycle, pulse width and power-off time, have been studied upon the Cu pulse emission profiles. The influence of discharge parameters, such as pressure and power, was studied as well. Results have shown that the intensity observed in the pre-peak can be 10 times as large as the plateau value for resonant lines and up to 5 times in case of transitions to the metastable levels. Increasing pressure or power increased the pre-peak intensity while its appearance in time changed. The pre-peak decreased when the discharge off-time was shorter than 100 {mu}s. According to such results, the presence of the pre-peak could be probably due to the lack of self-absorption during the first 50 {mu}s, and not to the ignition of the plasma. Under the selected operation conditions, the use of the pre-peak emission as analytical signals increases the linearity of calibration curves for resonant lines subjected to self-absorption at high concentrations.

  9. Comparison of equilibrium radionuclide and contrast angiographic measurements of left ventricular peak ejection and filling rates and their time intervals

    Energy Technology Data Exchange (ETDEWEB)

    Sugrue, D.D.; Dickie, S.; Newman, H.; Myers, M.J.; Lavender, J.P.; McKenna, W.J. (Royal Postgraduate Medical School, London (UK))

    1984-10-01

    A comparison has been made of the equilibrium radionuclide and contrast angiographic estimates of normalized peak rates of ejection (PER) and filling (PFR) and their time intervals in twenty-one patients with cardiac disorders. Contrast angiographic and radionuclide measurements of left ventricular ejection fraction (LVEF), PER and PFR correlated well but time intervals correlated poorly. Mean values for radionuclide LVEF, PER and PFR were significantly lower and radionuclide time intervals were significantly longer compared to contrast angiography measurements.

  10. The 64-MSCT study of relationship between renal corticomedullary differentiation, contrast between renal cortex and medulla, renal cortex and medulla CT peak value with the single renal function in hydronephrotic kidney

    International Nuclear Information System (INIS)

    Wang Yunhua; Hou Weiwei; Liu Ruihong; He Jianjun; Zhi Ke

    2009-01-01

    Objective: To study 64-MSCT perfusion imaging features about renal corticomedullary differentiation, contrast between renal cortex and medulla (CMC), renal cortex and medulla CT peak value in normal and hydronephrotic kidneys, and to explore the relationship between them and the unilateral renal function. Methods: Thirty-six patients with obstructive nephrohydrosis underwent 64-MSCT perfusion scanning. The split renal glomerular filtration rates (GFR) of their kidneys were measured by SPECT renal dynamic imaging. The 72 kidneys were divided into groups of normal renal function group, mild and severe renal impairment groups according to GFR. Renal corticomedullary differentiation on CT images was graded as clear, obscure, part clear. The CT intensity of cortex and medulla was measured in order to calculate contrast between renal cortex and medulla (CMC). Using Pearson correlation test, the correlation between them and renal GFR were examined. Results: (1) In the 24 kidneys of normal group, all kidneys showed clear CMD. In the 21 kidneys of mild renal impairment group, 14 kidneys showed clear CMD, 2 showed obscure CMD and 5 showed part clear of CMD. In the 27 kidneys of severe renal impairment group, 7 kidneys showed clear CMD, 5 showed obscure CMD and 15 showed part clear of CMD. (2)The CMC of normal group was 0.62 ± 0.20, while it was 0.52 ± 0.14 and 0.37 ± 0.11 for mild renal impairment group and severe renal impairment group CMC respectively. The CMC had positive linear correlation with GFR (r=0.536,P<0.05). (3) The renal cortex and medulla CT peak value of normal group were (133 ± 22) and (104 ± 16) HU; The renal cortex and medulla CT peak value of mild renal impairment group were (91 ± 29) and (76 ± 25) HU; The renal cortex and medulla CT peak value of severe renal impairment group were (68 ± 24) and (57 ± 21) HU(F=42.76 and 32.68,P<0.05). The renal cortex and medulla CT peak value had positive linear correlation with GFR (r=0.672 and 0.623, P<0

  11. Estimation of uncertainty bounds for individual particle image velocimetry measurements from cross-correlation peak ratio

    International Nuclear Information System (INIS)

    Charonko, John J; Vlachos, Pavlos P

    2013-01-01

    Numerous studies have established firmly that particle image velocimetry (PIV) is a robust method for non-invasive, quantitative measurements of fluid velocity, and that when carefully conducted, typical measurements can accurately detect displacements in digital images with a resolution well below a single pixel (in some cases well below a hundredth of a pixel). However, to date, these estimates have only been able to provide guidance on the expected error for an average measurement under specific image quality and flow conditions. This paper demonstrates a new method for estimating the uncertainty bounds to within a given confidence interval for a specific, individual measurement. Here, cross-correlation peak ratio, the ratio of primary to secondary peak height, is shown to correlate strongly with the range of observed error values for a given measurement, regardless of flow condition or image quality. This relationship is significantly stronger for phase-only generalized cross-correlation PIV processing, while the standard correlation approach showed weaker performance. Using an analytical model of the relationship derived from synthetic data sets, the uncertainty bounds at a 95% confidence interval are then computed for several artificial and experimental flow fields, and the resulting errors are shown to match closely to the predicted uncertainties. While this method stops short of being able to predict the true error for a given measurement, knowledge of the uncertainty level for a PIV experiment should provide great benefits when applying the results of PIV analysis to engineering design studies and computational fluid dynamics validation efforts. Moreover, this approach is exceptionally simple to implement and requires negligible additional computational cost. (paper)

  12. Activity measurement by using γ-ray sum peak method considering intake radioactivity and its application

    International Nuclear Information System (INIS)

    Miyahara, Hiroshi; Narita, Norihiko; Tomita, Kenichi; Katoh, Yoshichika; Mori, Chizuo; Momose, Takumaro; Shinohara, Kunihiko

    2000-01-01

    It is important to measure external and internal exposure dose in the case of accident. The external exposure can be measured by various dosimeters, but the internal exposure is usually calculated from estimated amounts of intake radioactivity because of difficulty of direct measurement. Detection efficiency of human counter used in direct measurement is necessary, but there is no effective method to determine it for non-uniform distribution. The γ-ray sum peak method is tried for the cascade γ-ray emitter under the consideration of small diffusion such as just after intake. After disintegration rates of sources of 46 Sc and 60 Co were determined by 4πβ-γ coincidence method, γ-ray spectra were measured at various positions. Calculated disintegration rates by sum peak method agreed with those by coincidence method within 10%. The similar results were obtained for distributed plural sources in restricted condition. It is also investigated as application for the case that the other nuclide is contained in it. Using peak-to-total ratios measured in advance, the disintegration rates were determined only from the peak intensities. In this case the results had systematic uncertainty of about 20%. (author)

  13. Factors influencing peak expiratory flow in teenage boys | van ...

    African Journals Online (AJOL)

    Background. Peak expiratory flow (PEF) is a useful measure of pulmonary health status and is frequently utilised in asthm, management. Reduction in PEF is usually indicative of onset (of asthma symptoms. However, use can be made of PEF values only if normal values are known. The definition of normal range is always ...

  14. Unusual Physical Properties of the Chicxulub Crater Peak Ring: Results from IODP/ICDP Expedition 364

    Science.gov (United States)

    Christeson, G. L.; Gebhardt, C.; Gulick, S. P. S.; Le Ber, E.; Lofi, J.; Morgan, J. V.; Nixon, C.; Rae, A.; Schmitt, D. R.

    2017-12-01

    IODP/ICDP Expedition 364 Hole M0077A drilled into the peak ring of the Chicxulub impact crater, recovering core between 505.7 and 1334.7 m below the seafloor (mbsf). Physical property measurements include wireline logging data, a vertical seismic profile (VSP), Multi-Sensor Core Logger (MSCL) measurements, and discrete sample measurements. The Hole M0077A peak ring rocks have unusual physical properties. Across the boundary between post-impact sediment and crater breccia we measure a sharp decrease in velocities and densities, and an increase in porosity. Mean crater breccia values are 3000-3300 m/s, 2.14-2.15 g/cm3, and 31% for velocity, density, and porosity, respectively. This zone is also associated with a low-frequency reflector package on MCS profiles and a low-velocity layer in FWI images, both confirmed from the VSP dataset. The thin (24 m) crater melt unit has mean velocity measurements of 3800-4150 m/s, density measurements of 2.32-2.34 g/cm3, and porosity measurements of 20%; density and porosity values are intermediate between the overlying impact breccia and underlying granitic basement, while the velocity values are similar to those for the underlying basement. The Hole M0077A crater melt unit velocities and densities are considerably less than values of 5800 m/s and 2.68 g/cm3 measured at an onshore well located in the annular trough. The uplifted granitic peak ring materials have mean values of 4100-4200 m/s, 2.39-2.44 g/cm3, and 11% for compressional wave velocity, density, and porosity, respectively; these values differ significantly from typical granite which has higher velocities (5400-6000 m/s) and densities (2.62-2.67 g/cm3), and lower porosities (<1%). All Hole M0077A peak-ring velocity, density, and porosity measurements indicate considerable fracturing, and are consistent with numerical models for peak-ring formation.

  15. The Prognostic Value of Left Atrial Peak Reservoir Strain in Acute Myocardial Infarction Is Dependent on Left Ventricular Longitudinal Function and Left Atrial Size

    DEFF Research Database (Denmark)

    Ersbøll, Mads; Andersen, Mads J; Valeur, Nana

    2013-01-01

    of PALS and left ventricular longitudinal strain (global longitudinal strain) in large-scale populations in regard to prognosis. METHODS AND RESULTS: We prospectively included 843 patients (mean age 62.1+/-11.8; 74% male) with acute myocardial infarction and measured global longitudinal strain, left......BACKGROUND: Peak atrial longitudinal strain (PALS) during the reservoir phase has been proposed as a measure of left atrium function in a range of cardiac conditions, with the potential for added pathophysiological insight and prognostic value. However, no studies have assessed the interrelation...

  16. Comparative Analysis of Mass Spectral Similarity Measures on Peak Alignment for Comprehensive Two-Dimensional Gas Chromatography Mass Spectrometry

    Science.gov (United States)

    2013-01-01

    Peak alignment is a critical procedure in mass spectrometry-based biomarker discovery in metabolomics. One of peak alignment approaches to comprehensive two-dimensional gas chromatography mass spectrometry (GC×GC-MS) data is peak matching-based alignment. A key to the peak matching-based alignment is the calculation of mass spectral similarity scores. Various mass spectral similarity measures have been developed mainly for compound identification, but the effect of these spectral similarity measures on the performance of peak matching-based alignment still remains unknown. Therefore, we selected five mass spectral similarity measures, cosine correlation, Pearson's correlation, Spearman's correlation, partial correlation, and part correlation, and examined their effects on peak alignment using two sets of experimental GC×GC-MS data. The results show that the spectral similarity measure does not affect the alignment accuracy significantly in analysis of data from less complex samples, while the partial correlation performs much better than other spectral similarity measures when analyzing experimental data acquired from complex biological samples. PMID:24151524

  17. Experimental evaluation of IGBT junction temperature measurement via peak gate current

    DEFF Research Database (Denmark)

    Baker, Nick; Munk-Nielsen, Stig; Iannuzzo, Francesco

    2015-01-01

    Temperature sensitive electrical parameters allow junction temperature measurements on power semiconductors without modification to module packaging. The peak gate current has recently been proposed for IGBT junction temperature measurement and relies on the temperature dependent resistance...... of the gate pad. Consequently, a consideration of chip geometry and location of the gate pad is required before interpreting temperature data from this method. Results are also compared with a traditional electrical temperature measurement method: the voltage drop under low current....

  18. THE EFFECT OF GENDER AND FATIGUE ON THE BIOMECHANICS OF BILATERAL LANDINGS FROM A JUMP: PEAK VALUES

    Directory of Open Access Journals (Sweden)

    Evangelos Pappas

    2007-03-01

    Full Text Available Female athletes are substantially more susceptible than males to suffer acute non-contact anterior cruciate ligament injury. A limited number of studies have identified possible biomechanical risk factors that differ between genders. The effect of fatigue on the biomechanics of landing has also been inadequately investigated. The objective of the study was to examine the effect of gender and fatigue on peak values of biomechanical variables during landing from a jump. Thirty-two recreational athletes performed bilateral drop jump landings from a 40 cm platform. Kinetic, kinematic and electromyographic data were collected before and after a functional fatigue protocol. Females landed with 9° greater peak knee valgus (p = 0.001 and 140% greater maximum vertical ground reaction forces (p = 0.003 normalized to body weight compared to males. Fatigue increased peak foot abduction by 1.7° (p = 0.042, peak rectus femoris activity by 27% (p = 0.018, and peak vertical ground reaction force (p = 0.038 by 20%. The results of the study suggest that landing with increased peak knee valgus and vertical ground reaction force may contribute to increased risk for knee injury in females. Fatigue caused significant but small changes on some biomechanical variables. Anterior cruciate ligament injury prevention programs should focus on implementing strategies to effectively teach females to control knee valgus and ground reaction force

  19. Values of kinetic features measured by computer-aided for breast MRI

    International Nuclear Information System (INIS)

    Zhang Lina; Zhao Zuowei; Song Qingwei; Wang Shaowu; Miao Yanwei

    2012-01-01

    Objective: To investigate the value of kinetic features measured by computer-aided diagnosis (CAD) for breast MRI. Methods: One hundred and sixty four lesions diagnosed pathologically by operation or biopsy comprised the analysis set. Automated lesion kinetic information from CADStream programs for breast MRI was identified. Three CAD variables were compared for benign and malignant lesions: initial phase peak enhancement (greatest percentage of signal intensity increase on first contrast enhanced sequence), delayed phase enhancement categorized by a single type of kinetics comprising the largest percentage of enhancement (washout, plateau, or persistent), and delayed phase enhancement categorized by single most suspicious type of kinetics (any washout > any plateau > any persistent). Morphological characteristics of breast lesions were described according to breast imaging and reporting data system (BI-RADS). Initial phase peak enhancement mean values between benign and malignant breast lesions were compared by using Wilcoxon rank-sum test, delayed phase enhancement categorized by a single type of kinetics comprising the largest percentage of enhancement or by single most suspicious type of kinetics between benign and malignant breast lesions were compared by using Chi-square test. Results: There were 72 benign and 92 malignant breast lesions. A total of 123 (75.0%) mass lesions were identified,and the other 41 (25.0%) lesions showed no mass. Thirty lesions were BI-RADS-MRI 2, 68 lesions were BI-RADS-MRI 3, 43 lesions were BI-RADS-MRI 4, 23 lesions were BI-RADS-MRI 5. Initial phase peak enhancement mean values of benign and malignant lesions were 237% (69% to 629%) and 336% (86% to 793%), respectively. There was no significant difference between benign and malignant lesions in initial peak enhancement mean value (Z=-1.626, P=0.104). Delayed phase enhancement categorized by single most suspicious type of kinetics (any washout > any plateau > any persistent) for

  20. Trabecular bone mineral density measured by quantitative CT of the lumbar spine in children and adolescents: reference values and peak bone mass; Trabekulaere Knochendichte der Lendenwirbelsaeule bei Kindern und Jugendlichen in der quantitativen CT: Referenzwerte und Peak Bone Mass

    Energy Technology Data Exchange (ETDEWEB)

    Berthold, L.D.; Alzen, G. [Kinderradiologie, Zentrum fuer Radiologie, Universitaetsklinikum Giessen und Marburg GmbH, Standort Giessen (Germany); Haras, G. [Siemens AG, Medical Solutions, Forchheim (Germany); Mann, M. [AG Medizinische Statistik, Universitaetsklinikum Giessen und Marburg GmbH, Standort Giessen (Germany)

    2006-12-15

    Purpose: The aim of this study was to assess bone density values in the trabecular substance of the lumbar vertebral column in children and young adults in Germany from infancy to the age of peak bone mass. Materials and Methods: We performed quantiative computed tomography (QCT) on the first lumbar vertebra in 28 children and adolescents without diseases that may influence bone metabolism (15 boys, 13 girls, mean ages 11 and 8 years, respectively). We also measured 17 healthy young adults (9 men, 8 women, mean ages 20 and 21 years). We used a Somatom Balance Scanner (Siemens, Erlangen) and the Siemens Osteo software. Scan parameters: Slice thickness 1 cm, 80 kV, 81 or 114 mAs. We measured the trabecular bone density and the area and height of the vertebra and calculated the volume and content of calcium hydroxyapatite (Ca-HA) in the trabecular substance of the first lumbar vertebra. Results: Prepubertal boys had a mean bone density of 148.5 (median [med] 150.1, standard deviation [SD] 15.4) mg/Ca-HA per ml bone, and prepubertal girls had a mean density of 149.5 (med 150.8, SD 23.5) mg/ml. We did not observe a difference between prepubertal boys and girls. After puberty there was a significant difference (p<0.001) between males and females: Mean density (male) 158.0, med 162.5, SD 24.0 mg/ml, mean density (female) 191.2, med 191.3, SD 17.7 mg/ml. The Ca-HA content in the trabecular bone of the first lumbar vertebra was 1.1 (med 1.1, SD 0.5) g for prepubertal boys and 1.1 (0.9, 0.4) g for prepubertal girls. For post-pubertal males, the mean Ca-HA content was 3.5 g, med 3.5 SD 0.5 g, and for post-pubertal females, the mean content was 2.8, med 2.7, SD 0.4 g. Conclusion: The normal trabecular bone mineral density is 150 mg/ml with a standard deviation of 20 mg/ml independent of age or gender until the beginning of puberty. Peak bone mass (bone mineral content) in the trabecular substance of the lumbar vertebral column is higher in males than in females, and peak bone

  1. Comparison of five portable peak flow meters

    Directory of Open Access Journals (Sweden)

    Glaucia Nency Takara

    2010-01-01

    Full Text Available OBJECTIVE: To compare the measurements of spirometric peak expiratory flow (PEF from five different PEF meters and to determine if their values are in agreement. Inaccurate equipment may result in incorrect diagnoses of asthma and inappropriate treatments. METHODS: Sixty-eight healthy, sedentary and insufficiently active subjects, aged from 19 to 40 years, performed PEF measurements using Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® peak flow meters. The highest value recorded for each subject for each device was compared to the corresponding spirometric values using Friedman's test with Dunn's post-hoc (p<0.05, Spearman's correlation test and Bland-Altman's agreement test. RESULTS: The median and interquartile ranges for the spirometric values and the Air Zone®, Assess®, Galemed®, Personal Best® and Vitalograph® meters were 428 (263-688 L/min, 450 (350-800 L/min, 420 (310-720 L/min, 380 (300-735 L/min, 400 (310-685 L/min and 415 (335-610 L/min, respectively. Significant differences were found when the spirometric values were compared to those recorded by the Air Zone® (p<0.001 and Galemed ® (p<0.01 meters. There was no agreement between the spirometric values and the five PEF meters. CONCLUSIONS: The results suggest that the values recorded from Galemed® meters may underestimate the actual value, which could lead to unnecessary interventions, and that Air Zone® meters overestimate spirometric values, which could obfuscate the need for intervention. These findings must be taken into account when interpreting both devices' results in younger people. These differences should also be considered when directly comparing values from different types of PEF meters.

  2. Peak Measurement for Vancomycin AUC Estimation in Obese Adults Improves Precision and Lowers Bias.

    Science.gov (United States)

    Pai, Manjunath P; Hong, Joseph; Krop, Lynne

    2017-04-01

    Vancomycin area under the curve (AUC) estimates may be skewed in obese adults due to weight-dependent pharmacokinetic parameters. We demonstrate that peak and trough measurements reduce bias and improve the precision of vancomycin AUC estimates in obese adults ( n = 75) and validate this in an independent cohort ( n = 31). The precision and mean percent bias of Bayesian vancomycin AUC estimates are comparable between covariate-dependent ( R 2 = 0.774, 3.55%) and covariate-independent ( R 2 = 0.804, 3.28%) models when peaks and troughs are measured but not when measurements are restricted to troughs only ( R 2 = 0.557, 15.5%). Copyright © 2017 American Society for Microbiology.

  3. Reconstructing weak values without weak measurements

    International Nuclear Information System (INIS)

    Johansen, Lars M.

    2007-01-01

    I propose a scheme for reconstructing the weak value of an observable without the need for weak measurements. The post-selection in weak measurements is replaced by an initial projector measurement. The observable can be measured using any form of interaction, including projective measurements. The reconstruction is effected by measuring the change in the expectation value of the observable due to the projector measurement. The weak value may take nonclassical values if the projector measurement disturbs the expectation value of the observable

  4. Validation of an assay for quantification of free normetanephrine, metanephrine and methoxytyramine in plasma by high performance liquid chromatography with coulometric detection: Comparison of peak-area vs. peak-height measurements.

    Science.gov (United States)

    Nieć, Dawid; Kunicki, Paweł K

    2015-10-01

    Measurements of plasma concentrations of free normetanephrine (NMN), metanephrine (MN) and methoxytyramine (MTY) constitute the most diagnostically accurate screening test for pheochromocytomas and paragangliomas. The aim of this article is to present the results from a validation of an analytical method utilizing high performance liquid chromatography with coulometric detection (HPLC-CD) for quantifying plasma free NMN, MN and MTY. Additionally, peak integration by height and area and the use of one calibration curve for all batches or individual calibration curve for each batch of samples was explored as to determine the optimal approach with regard to accuracy and precision. The method was validated using charcoal stripped plasma spiked with solutions of NMN, MN, MTY and internal standard (4-hydroxy-3-methoxybenzylamine) with the exception of selectivity which was evaluated by analysis of real plasma samples. Calibration curve performance, accuracy, precision and recovery were determined following both peak-area and peak-height measurements and the obtained results were compared. The most accurate and precise method of calibration was evaluated by analyzing quality control samples at three concentration levels in 30 analytical runs. The detector response was linear over the entire tested concentration range from 10 to 2000pg/mL with R(2)≥0.9988. The LLOQ was 10pg/mL for each analyte of interest. To improve accuracy for measurements at low concentrations, a weighted (1/amount) linear regression model was employed, which resulted in inaccuracies of -2.48 to 9.78% and 0.22 to 7.81% following peak-area and peak-height integration, respectively. The imprecisions ranged from 1.07 to 15.45% and from 0.70 to 11.65% for peak-area and peak-height measurements, respectively. The optimal approach to calibration was the one utilizing an individual calibration curve for each batch of samples and peak-height measurements. It was characterized by inaccuracies ranging from -3

  5. Relaxation peak near 200 K in NiTi alloy

    Science.gov (United States)

    Zhu, J. S.; Schaller, R.; Benoit, W.

    1989-10-01

    Internal friction (IF), frequency ( f), electrical resistance ( R) and zero point movement of the torsion pendulum (ɛ) have been measured in near equi-atomic NiTi alloy in order to clarify the mechanism for the relaxation peak near 200 K. The height of the relaxation peak decreases successively with thermal cycling and settles down to a lower stable value in running 15 cycles. However, the electrical resistance of the sample shows a variation in contrast with the internal friction. Both of them will return to the initial state after a single annealing at 773 K for 1 h. The probable mechanism of this relaxation peak was discussed.

  6. Limitation of peak fitting and peak shape methods for determination of activation energy of thermoluminescence glow peaks

    CERN Document Server

    Sunta, C M; Piters, T M; Watanabe, S

    1999-01-01

    This paper shows the limitation of general order peak fitting and peak shape methods for determining the activation energy of the thermoluminescence glow peaks in the cases in which retrapping probability is much higher than the recombination probability and the traps are filled up to near saturation level. Right values can be obtained when the trap occupancy is reduced by using small doses or by post-irradiation partial bleaching. This limitation in the application of these methods has not been indicated earlier. In view of the unknown nature of kinetics in the experimental samples, it is recommended that these methods of activation energy determination should be applied only at doses well below the saturation dose.

  7. Primary activity standardization of {sup 57}Co by sum-peak method

    Energy Technology Data Exchange (ETDEWEB)

    Iwahara, A. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)/Instituto de Radioprotecao e Dosimetria (IRD)/Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/no. Recreio dos Bandeirantes - CEP 22780-160 Rio de Janeiro (Brazil)], E-mail: iwahara@ird.gov.br; Poledna, R.; Silva, C.J. da; Tauhata, L. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)/Instituto de Radioprotecao e Dosimetria (IRD)/Comissao Nacional de Energia Nuclear - CNEN, Av. Salvador Allende, s/no. Recreio dos Bandeirantes - CEP 22780-160 Rio de Janeiro (Brazil)

    2009-10-15

    The sum-peak method was applied to standardize a {sup 57}Co solution within the framework of an international comparison organized by International Atomic Energy Agency, in 2008, aimed toward international traceability of activity measurements. A planar germanium detector was used with the sources placed on top of the detector for activity determination measurements. An analytical expression for accidental summing correction was derived and the effect of the germanium characteristic KX-ray escape peak of 112 keV was taken into account. The standard uncertainty associated to the activity concentration value was 0.37% and the result was compared with other measurement methods.

  8. Hydration-coupled protein boson peak measured by incoherent neutron scattering

    International Nuclear Information System (INIS)

    Nakagawa, Hiroshi; Kataoka, Mikio; Joti, Yasumasa; Kitao, Akio; Shibata, Kaoru; Tokuhisa, Atsushi; Tsukushi, Itaru; Go, Nobuhiro

    2006-01-01

    The boson peak of a protein was examined in relation to hydration using staphylococcal nuclease. Although the boson peak is commonly observed in synthetic polymers, glassy materials and amorphous materials, the origin of the boson peak is not fully understood. The motions that contribute to the peak are harmonic vibrations. Upon hydration the peak frequency shifts to a higher frequency and the effective force constant of the vibration increases at low temperatures, suggesting that the protein energy surface is modified. Hydration of the protein leads to a more rugged surface and the vibrational motions are trapped within the local minimum at cryogenic temperatures. The origin of the protein boson peak may be related to this rugged energy surface

  9. Selection of values of design peak heat flux to reduce the risk of waterside corrosion in F.R. steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Bolt, P R; Garnsey, R

    1975-07-01

    Attention is drawn to the high levels of peak heat Flux that can exist in sodium heated steam generators. The strength of the relationship between heat, flux and both deposition rate and the concentration of salts is discussed. Relevant steam generator operational experience obtained on the C.E.G.B. system is described and tentative proposals are made for limits to he to the peak heat flux values used in F.R. steam generator design. (author)

  10. Selection of values of design peak heat flux to reduce the risk of waterside corrosion in F.R. steam generators

    International Nuclear Information System (INIS)

    Bolt, P.R.; Garnsey, R.

    1975-01-01

    Attention is drawn to the high levels of peak heat Flux that can exist in sodium heated steam generators. The strength of the relationship between heat, flux and both deposition rate and the concentration of salts is discussed. Relevant steam generator operational experience obtained on the C.E.G.B. system is described and tentative proposals are made for limits to he to the peak heat flux values used in F.R. steam generator design. (author)

  11. Measurements of bundle end flux peaking effects in 37-element CANDU PHW fuel

    International Nuclear Information System (INIS)

    French, P.M.

    1977-10-01

    Thermal neutron bundle end flux peaking factors have been measured in fresh 37-element Bruce reactor natural UO 2 clusters in heavy water moderator, both with and without staggered plenums at the fuel stack ends, in representative elements throughout the clusters. The measurements were made at a square lattice pitch of 28.58 cm with heavy water coolant. The results indicate that outer element peaking factors are 1.142 +- 0.009 for bundles containing no plenums, and 1.155 +- 0.006 and 1.177 +- 0.006 at the non-plenum and plenum element ends respectively, for bundles containing staggered plenums, irrespective of the azimuthal orientation between pairs of bundles. Measurements are also reported for bundles containing plenums in every outer element, for bundles separated by a stainless steel flux suppressor, for longer graphite plenums, and for changes in plenum and bundle gap lengths. Some theoretical comparisons with the results, reported by other authors, have been summarized. (author)

  12. Predictors of VO2Peak in children age 6- to 7-years-old

    DEFF Research Database (Denmark)

    Dencker, Magnus; Hermansen, Bianca; Bugge, Anna

    2011-01-01

    This study investigated the predictors of aerobic fitness (VO2PEAK) in young children on a population-base. Participants were 436 children (229 boys and 207 girls) aged 6.7 ± 0.4 yrs. VO2PEAK was measured during a maximal treadmill exercise test. Physical activity was assessed by accelerometers....... Total body fat and total fat free mass were estimated from skinfold measurements. Regression analyses indicated that significant predictors for VO2PEAK per kilogram body mass were total body fat, maximal heart rate, sex, and age. Physical activity explained an additional 4-7%. Further analyses showed...... the main contributing factors for absolute values of VO2PEAK were fat free mass, maximal heart rate, sex, and age. Physical activity explained an additional 3-6%....

  13. The peak in neutron powder diffraction

    International Nuclear Information System (INIS)

    Laar, B. van; Yelon, W.B.

    1984-01-01

    For the application of Rietveld profile analysis to neutron powder diffraction data a precise knowledge of the peak profile, in both shape and position, is required. The method now in use employs a Gaussian shaped profile with a semi-empirical asymmetry correction for low-angle peaks. The integrated intensity is taken to be proportional to the classical Lorentz factor calculated for the X-ray case. In this paper an exact expression is given for the peak profile based upon the geometrical dimensions of the diffractometer. It is shown that the asymmetry of observed peaks is well reproduced by this expression. The angular displacement of the experimental profile with respect to the nominal Bragg angle value is larger than expected. Values for the correction to the classical Lorentz factor for the integrated intensity are given. The exact peak profile expression has been incorporated into a Rietveld profile analysis refinement program. (Auth.)

  14. Automated Peak Picking and Peak Integration in Macromolecular NMR Spectra Using AUTOPSY

    Science.gov (United States)

    Koradi, Reto; Billeter, Martin; Engeli, Max; Güntert, Peter; Wüthrich, Kurt

    1998-12-01

    A new approach for automated peak picking of multidimensional protein NMR spectra with strong overlap is introduced, which makes use of the program AUTOPSY (automatedpeak picking for NMRspectroscopy). The main elements of this program are a novel function for local noise level calculation, the use of symmetry considerations, and the use of lineshapes extracted from well-separated peaks for resolving groups of strongly overlapping peaks. The algorithm generates peak lists with precise chemical shift and integral intensities, and a reliability measure for the recognition of each peak. The results of automated peak picking of NOESY spectra with AUTOPSY were tested in combination with the combined automated NOESY cross peak assignment and structure calculation routine NOAH implemented in the program DYANA. The quality of the resulting structures was found to be comparable with those from corresponding data obtained with manual peak picking.

  15. Changes in Peak Airflow Measurement During Maximal Cough After Vocal Fold Augmentation in Patients With Glottic Insufficiency.

    Science.gov (United States)

    Dion, Gregory R; Achlatis, Efstratios; Teng, Stephanie; Fang, Yixin; Persky, Michael; Branski, Ryan C; Amin, Milan R

    2017-11-01

    Compromised cough effectiveness is correlated with dysphagia and aspiration. Glottic insufficiency likely yields decreased cough strength and effectiveness. Although vocal fold augmentation favorably affects voice and likely improves cough strength, few data exist to support this hypothesis. To assess whether vocal fold augmentation improves peak airflow measurements during maximal-effort cough following augmentation. This case series study was conducted in a tertiary, academic laryngology clinic. Participants included 14 consecutive individuals with glottic insufficiency due to vocal fold paralysis, which was diagnosed via videostrobolaryngoscopy as a component of routine clinical examination. All participants who chose to proceed with augmentation were considered for the study whether office-based or operative augmentation was planned. Postaugmentation data were collected only at the first follow-up visit, which was targeted for 14 days after augmentation but varied on the basis of participant availability. Data were collected from June 5, 2014, to October 1, 2015. Data analysis took place between October 2, 2015, and March 3, 2017. Peak airflow during maximal volitional cough was quantified before and after vocal fold augmentation. Participants performed maximal coughs, and peak expiratory flow during the maximal cough was captured according to American Thoracic Society guidelines. Among the 14 participants (7 men and 7 women), the mean (SD) age was 62 (18) years. Three types of injectable material were used for vocal fold augmentation: carboxymethylcellulose in 5 patients, hyaluronic acid in 5, and calcium hydroxylapatite in 4. Following augmentation, cough strength increased in 11 participants and decreased cough strength was observed in 3. Peak airflow measurements during maximal cough varied from a decrease of 40 L/min to an increase of 150 L/min following augmentation. When preaugmentation and postaugmentation peak airflow measurements were compared, the

  16. Electricity Portfolio Management: Optimal Peak / Off-Peak Allocations

    OpenAIRE

    Huisman, Ronald; Mahieu, Ronald; Schlichter, Felix

    2007-01-01

    textabstractElectricity purchasers manage a portfolio of contracts in order to purchase the expected future electricity consumption profile of a company or a pool of clients. This paper proposes a mean-variance framework to address the concept of structuring the portfolio and focuses on how to allocate optimal positions in peak and off-peak forward contracts. It is shown that the optimal allocations are based on the difference in risk premiums per unit of day-ahead risk as a measure of relati...

  17. Peak power ratio generator

    Science.gov (United States)

    Moyer, R.D.

    A peak power ratio generator is described for measuring, in combination with a conventional power meter, the peak power level of extremely narrow pulses in the gigahertz radio frequency bands. The present invention in a preferred embodiment utilizes a tunnel diode and a back diode combination in a detector circuit as the only high speed elements. The high speed tunnel diode provides a bistable signal and serves as a memory device of the input pulses for the remaining, slower components. A hybrid digital and analog loop maintains the peak power level of a reference channel at a known amount. Thus, by measuring the average power levels of the reference signal and the source signal, the peak power level of the source signal can be determined.

  18. EFFECT OF MEASUREMENT ERRORS ON PREDICTED COSMOLOGICAL CONSTRAINTS FROM SHEAR PEAK STATISTICS WITH LARGE SYNOPTIC SURVEY TELESCOPE

    Energy Technology Data Exchange (ETDEWEB)

    Bard, D.; Chang, C.; Kahn, S. M.; Gilmore, K.; Marshall, S. [KIPAC, Stanford University, 452 Lomita Mall, Stanford, CA 94309 (United States); Kratochvil, J. M.; Huffenberger, K. M. [Department of Physics, University of Miami, Coral Gables, FL 33124 (United States); May, M. [Physics Department, Brookhaven National Laboratory, Upton, NY 11973 (United States); AlSayyad, Y.; Connolly, A.; Gibson, R. R.; Jones, L.; Krughoff, S. [Department of Astronomy, University of Washington, Seattle, WA 98195 (United States); Ahmad, Z.; Bankert, J.; Grace, E.; Hannel, M.; Lorenz, S. [Department of Physics, Purdue University, West Lafayette, IN 47907 (United States); Haiman, Z.; Jernigan, J. G., E-mail: djbard@slac.stanford.edu [Department of Astronomy and Astrophysics, Columbia University, New York, NY 10027 (United States); and others

    2013-09-01

    We study the effect of galaxy shape measurement errors on predicted cosmological constraints from the statistics of shear peak counts with the Large Synoptic Survey Telescope (LSST). We use the LSST Image Simulator in combination with cosmological N-body simulations to model realistic shear maps for different cosmological models. We include both galaxy shape noise and, for the first time, measurement errors on galaxy shapes. We find that the measurement errors considered have relatively little impact on the constraining power of shear peak counts for LSST.

  19. Measuring the educational impact of Promoting Environmental Awareness in Kids (PEAK): The development and implementation of a new scale

    Science.gov (United States)

    Jennifer Miller; Lindsey Brown; Eddie Hill; Amy Shellman; Ron Ramsing; Edwin. Gómez

    2012-01-01

    The Leave No Trace Center for Outdoor Ethics (LNT) is a nonprofit educational organization that teaches skills and values for recreating responsibly in the out-of-doors. LNT developed Promoting Environmental Awareness in Kids (PEAK), based on seven ethical principles. The PEAK program provides a pack that contains several interactive activities specifically designed to...

  20. Prediction of peak overlap in NMR spectra

    International Nuclear Information System (INIS)

    Hefke, Frederik; Schmucki, Roland; Güntert, Peter

    2013-01-01

    Peak overlap is one of the major factors complicating the analysis of biomolecular NMR spectra. We present a general method for predicting the extent of peak overlap in multidimensional NMR spectra and its validation using both, experimental data sets and Monte Carlo simulation. The method is based on knowledge of the magnetization transfer pathways of the NMR experiments and chemical shift statistics from the Biological Magnetic Resonance Data Bank. Assuming a normal distribution with characteristic mean value and standard deviation for the chemical shift of each observable atom, an analytic expression was derived for the expected overlap probability of the cross peaks. The analytical approach was verified to agree with the average peak overlap in a large number of individual peak lists simulated using the same chemical shift statistics. The method was applied to eight proteins, including an intrinsically disordered one, for which the prediction results could be compared with the actual overlap based on the experimentally measured chemical shifts. The extent of overlap predicted using only statistical chemical shift information was in good agreement with the overlap that was observed when the measured shifts were used in the virtual spectrum, except for the intrinsically disordered protein. Since the spectral complexity of a protein NMR spectrum is a crucial factor for protein structure determination, analytical overlap prediction can be used to identify potentially difficult proteins before conducting NMR experiments. Overlap predictions can be tailored to particular classes of proteins by preparing statistics from corresponding protein databases. The method is also suitable for optimizing recording parameters and labeling schemes for NMR experiments and improving the reliability of automated spectra analysis and protein structure determination.

  1. The measurement of mass spectrometric peak height ratio of helium isotope in trace samples

    International Nuclear Information System (INIS)

    Sun Mingliang

    1989-01-01

    An experiment study on the measurement of mass spectrometric peak height ratio of helium isotope in the trace gaseous sample is discussed by using the gas purification line designed by the authors and model VG-5400 static-vacuum noble gas mass spectrometer imported and air helium as a standard. The results show that the amount of He and Ne in natural gas sample is 99% after purification. When the amount of He in Mass Spectrometer is more than 4 x 10 -7 cm 3 STP, it's sensitivity remains stable, about 10 -4 A/cm 3 STP He and the precision of 3 He/ 4 He ratio within the following 17 days is 1.32%. The 'ABA' pattern and experiment condition in the measurement of mass spectrometric peak height ratio of He isotope are presented

  2. Cosmology constraints from shear peak statistics in Dark Energy Survey Science Verification data

    International Nuclear Information System (INIS)

    Kacprzak, T.; Kirk, D.; Friedrich, O.; Amara, A.; Refregier, A.

    2016-01-01

    Shear peak statistics has gained a lot of attention recently as a practical alternative to the two-point statistics for constraining cosmological parameters. We perform a shear peak statistics analysis of the Dark Energy Survey (DES) Science Verification (SV) data, using weak gravitational lensing measurements from a 139 deg"2 field. We measure the abundance of peaks identified in aperture mass maps, as a function of their signal-to-noise ratio, in the signal-to-noise range 0 4 would require significant corrections, which is why we do not include them in our analysis. We compare our results to the cosmological constraints from the two-point analysis on the SV field and find them to be in good agreement in both the central value and its uncertainty. Lastly, we discuss prospects for future peak statistics analysis with upcoming DES data.

  3. Find - a computer program for peak search in gamma-ray spectra measured with Ge (Li) detectors

    International Nuclear Information System (INIS)

    Venturini, L.

    1988-01-01

    The program FIND is a FORTRAN IV computer code for peak search in spectra measured with Ge(Li) detectors. The program gives the position and estimates energy and relative significance for every peak found in the spectrum. The search in done by calculating a negative smoothed second difference of the experimental spectrum, as suggested by Phillips and Marlow (1). (author) [pt

  4. The Locations of Ring Current Pressure Peaks: Comparison of TWINS Measurements and CIMI Simulations for the 7-10 September 2015 CIR Storm

    Science.gov (United States)

    Hill, S. C.; Edmond, J. A.; Xu, H.; Perez, J. D.; Fok, M. C. H.; Goldstein, J.; McComas, D. J.; Valek, P. W.

    2017-12-01

    The characteristics of a four day 7-10 September 2015 co-rotating interaction region (CIR) storm (min. SYM/H ≤ -110 nT) are categorized by storm phase. Ion distributions of trapped particles in the ring current as measured by the Two Wide-Angle Imaging Neutral Atom Spectrometers (TWINS) are compared with the simulated ion distributions of the Comprehensive Inner Magnetosphere-Ionosphere Model (CIMI). The energetic neutral atom (ENA) images obtained by TWINS are deconvolved to extract equatorial pitch angle, energy spectra, ion pressure intensity, and ion pressure anisotropy distributions in the inner magnetosphere. CIMI, using either a self-consistent electric field or a semi-empirical electric field, simulates comparable distributions. There is good agreement between the data measured by TWINS and the different distributions produced by the self-consistent electric field and the semi-empirical electric field of CIMI. Throughout the storm the pitch angle distribution (PAD) is mostly perpendicular in both CIMI and TWINS and there is agreement between the anisotropy distributions. The locations of the ion pressure peaks seen by TWINS and by the self-consistent and semi empirical electric field parameters in CIMI are usually between dusk and midnight. On average, the self-consistent electric field in CIMI reveals ion pressure peaks closer to Earth than its semi empirical counterpart, while TWINS reports somewhat larger radial values for the ion pressure peak locations. There are also notable events throughout the storm during which the simulated observations show some characteristics that differ from those measured by TWINS. At times, there are ion pressure peaks with magnetic local time on the dayside and in the midnight to dawn region. We discuss these events in light of substorm injections indicated by fluctuating peaks in the AE index and a positive By component in the solar wind. There are also times in which there are multiple ion pressure peaks. This may

  5. Peak-by-peak correction of Ge(Li) gamma-ray spectra for photopeaks from background

    Energy Technology Data Exchange (ETDEWEB)

    Cutshall, N H; Larsen, I L [Oak Ridge National Lab., TN (USA)

    1980-12-01

    Background photopeaks can interfere with accurate measurement of low levels of radionuclides by gamma-ray spectrometry. A flowchart for peak-by-peak correction of sample spectra to produce accurate results is presented.

  6. Noise distribution of a peak track and hold circuit

    International Nuclear Information System (INIS)

    Seller, Paul; Hardie, Alec L.; Morrissey, Quentin

    2012-01-01

    Noise in linear electronic circuits is well characterised in terms of power spectral density in the frequency domain and the Normal probability density function in the time domain. For instance a charge preamplifier followed by a simple time independent pulse shaping circuit produces an output with a predictable, easily calculated Normal density function. By the Ergodic Principle this is true if the signal is sampled randomly in time or the experiment is run many times and measured at a fixed time after the circuit is released from reset. Apart from well defined cases, the time of the sample after release of reset does not affect the density function. If this signal is then passed through a peak track-and-hold circuit the situation is very different. The probability density function of the sampled signal is no longer Normal and the function changes with the time of the sample after release of reset. This density function can be classified by the Gumbel probability density function which characterises the Extreme Value Distribution of a defined number of Normally distributed values. The number of peaks in the signal is an important factor in the analysis. This issue is analysed theoretically and compared with a time domain noise simulation programme. This is then related to a real electronic circuit used for low-noise X-ray measurements and shows how the low-energy resolution of this system is significantly degraded when using a peak track-and-hold.

  7. Peak-by-peak correction of Ge(Li) gamma-ray spectra for photopeaks from background

    International Nuclear Information System (INIS)

    Cutshall, N.H.; Larsen, I.L.

    1980-01-01

    Background photopeaks can interfere with accurate measurement of low levels of radionuclides by gamma-ray spectrometry. A flowchart for peak-by-peak correction of sample spectra to produce accurate results is presented. (orig.)

  8. Monitoring device for local power peaking coefficients

    International Nuclear Information System (INIS)

    Mihashi, Ishi

    1987-01-01

    Purpose: To determine and monitor the local power peaking coefficients by a method not depending on the combination of fuel types. Constitution: Representative values for the local power distribution can be obtained by determining corresponding burn-up degrees based on the burn-up degree of each of fuel assembly segments obtained in a power distribution monitor and by the interpolation and extrapolation of void coefficients. The typical values are multiplied with compensation coefficients for the control rod effect and coefficients for compensating the effect of adjacent fuel assemblies in a calculation device to obtain typical values for the present local power distribution compensated with all of the effects. Further, the calculation device compares them with typical values of the present local power distribution to obtain an aimed local power peaking coefficient as the maximum value thereof. According to the present invention, since the local power peaking coefficients can be determined not depending on the combination of the kind of fuels, if the combination of fuel assemblies is increased upon fuel change, the amount of operation therefor is not increased. (Kamimura, M.)

  9. On Some Statistical Properties of GRBs with Measured Redshifts Having Peaks in Optical Light Curves

    Directory of Open Access Journals (Sweden)

    Grigorii Beskin

    2013-01-01

    Full Text Available We studied the subset of optical light curves of gamma-ray bursts with measured redshifts and well-sampled R band data that have clearly detected peaks. Among 43 such events, 11 are promptoptical peaks (P, coincident with gamma-ray activity, 22 are purely afterglows (A, and 10 more carrythe signatures of an underlying activity (A(U. We studied pair correlations of their gamma-ray andoptical parameters, e.g. total energetics, peak optical luminosities, and durations. The main outcomeof our study is the detection of source frame correlations between both optical peak luminosity and total energy and the redshift for classes A and A(U, and the absence of such a correlation for class Pevents. This result seems to provide evidence of the cosmological evolution of a medium around the burst defining class A and A(U energetics, and the absence of cosmological evolution of the internal properties of GRB engines. We also discuss some other prominent correlations.

  10. The influence of disease severity and lifestyle factors on the peak annual 25(OHD value of COPD patients

    Directory of Open Access Journals (Sweden)

    Kentson M

    2018-04-01

    Full Text Available Magnus Kentson,1,2 Per Leanderson,3 Petra Jacobson,4,5 Hans Lennart Persson4,5 1Division of Medicine, Ryhov Hospital, Jönköping, Sweden; 2Department of Medical and Health Sciences (IMH, Linköping University, Linköping, Sweden; 3Department of Occupational and Environmental Medicine, Department of Clinical and Experimental Medicine (IKE, Linköping University, Linköping, Sweden; 4Department of Respiratory Medicine, 5Department of Medical and Health Sciences (IMH, Linköping University, Linköping, Sweden Background: The prevalence of individuals deficient in vitamin D (defined as a serum level of the stable metabolite 25(OHD <50 nmol/L is increasing in countries with low annual ultraviolet (UV radiation and among individuals unable to perform outdoor activities, for example, COPD patients. Objective: To assess the role of vitamin D deficiency, independently of seasonal variation, the peak annual value of 25(OHD was measured in subjects with advanced COPD ± long-term oxygen therapy (LTOT and lung healthy control subjects. A method to grade the individual annual UV light exposure was designed and tested. Subjects and methods: Sixty-six Caucasians with advanced COPD (28 with LTOT and 47 control subjects were included, and the levels of 25(OHD were determined in late summer/early fall when the annual peak was assumed. Questionnaires about COPD symptoms, general health, lifestyle, dietary habits and QoL were used to collect data. Lung function tests and blood sampling were performed. Results: The peak annual 25(OHD of COPD subjects was significantly lower than in the control subjects, but there was no significant difference between COPD patients with and without LTOT. Ongoing vitamin D supplementation was the single most important intervention to maintain 25(OHD levels ≥50 nmol/L. Among vitamin D-deficient COPD subjects, 25(OHD correlated positively with forced expiratory volume in 1 second as % predicted, Modified British Medical Research

  11. Peak bone mass density among residents of Metro Manila

    International Nuclear Information System (INIS)

    Lim-Abrahan, M.A.B.; Guanzon, M.L.V.V.; Balderas, J.A.J.; Villaruel, C.M.; Santos, F.

    1996-01-01

    To determine the peak bone mass density among residents of Metro Manila using dual x-ray absorptiometry (DEXA).The design used is cross-sectional study. The study include 23 females and 22 males, with 3 to 4 subjects for each age range of 5. The methods used was bone mass density measurements on the lumbar spine and the femur using dual x-ray absorptiometry (DPXI lunar) were taken. The values were also age-matched and matched with that of a young adult based on programmed Caucasian norm provided by Lunar Co. The values were then scattered against age for each sex. Ten (10) cc of blood was also extracted from the patients, with 5 cc of blood separated for future studies. Patients were also interviewed as to their lifestyle, diet, use of contraceptive pill or hormonal replacement treatment, using a Filipino version of the revised questionnaire on the WHO Study on osteoporosis. The mean bone mass density at the L21.4 level for females was 1.12±0.11 g/cm 2 and 0,91±0.11 g/cm 2 at the femur. The highest BMD in both the lumbar spine femoral neck measurements among females was achieved between the ages 30-35 years of age with the lowest BMD occurring between 15-20 yrs. old and incidentally in 2 subjects with ages between 40-44. There seems to be little bone loss among beyond the age 35, unlike in the females. Bone mass density among a sample Metro Manila residents was determined using DEXA and the measurements on the lumbar spine and femoral neck. These were age-matched with that of young adult based on Caucasian norm provided by the Lunar Co. Peak bone mass density in the L2L4 level among the females is reached between the ages 30-35 years old, after which there is progressive bone loss with values in the 45-50 years old approximating the values in the 15-19 years old age range. A similar pattern is seen in the measurements taken at the femoral neck. Among males, the peak BMD is reached during the 30-35 years old, but there seems to be no rapid decline or rapid bone

  12. Total peak shape analysis: detection and quantitation of concurrent fronting, tailing, and their effect on asymmetry measurements.

    Science.gov (United States)

    Wahab, M Farooq; Patel, Darshan C; Armstrong, Daniel W

    2017-08-04

    Most peak shapes obtained in separation science depart from linearity for various reasons such as thermodynamic, kinetic, or flow based effects. An indication of the nature of asymmetry often helps in problem solving e.g. in column overloading, slurry packing, buffer mismatch, and extra-column band broadening. However, existing tests for symmetry/asymmetry only indicate the skewness in excess (tail or front) and not the presence of both. Two simple graphical approaches are presented to analyze peak shapes typically observed in gas, liquid, and supercritical fluid chromatography as well as capillary electrophoresis. The derivative test relies on the symmetry of the inflection points and the maximum and minimum values of the derivative. The Gaussian test is a constrained curve fitting approach and determines the residuals. The residual pattern graphically allows the user to assess the problematic regions in a given peak, e.g., concurrent tailing or fronting, something which cannot be easily done with other current methods. The template provided in MS Excel automates this process. The total peak shape analysis extracts the peak parameters from the upper sections (>80% height) of the peak rather than the half height as is done conventionally. A number of situations are presented and the utility of this approach in solving practical problems is demonstrated. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Effect of duration of contrast material injection on peak enhancement times and values of the aorta, main portal vein, and liver at dynamic MDCT with the dose of contrast medium tailored to patient weight

    International Nuclear Information System (INIS)

    Erturk, S.M.; Ichikawa, T.; Sou, H.; Tsukamoto, T.; Motosugi, U.; Araki, T.

    2008-01-01

    Aim: To investigate the effects of contrast material injection duration on peak enhancement times and attenuation values of the aorta, main portal vein, and liver at MDCT when the dose of contrast material is adjusted to patient weight. Material and methods: Seventy-five patients were randomly assigned to one of five groups, with durations of injection of 25, 30, 35, 40, or 45 s. All patients were injected with 2 ml/kg iodine (300 mg/ml). Attenuation values and peak enhancement times for the aorta, main portal vein, and liver were determined. The relationship between patient weight and enhancement times and values, the differences regarding peak enhancement times, and the relationship between injection duration and enhancement values were investigated using Pearson correlation, analysis of variance (ANOVA), and Spearman rank correlation, respectively. Results: No significant correlations were seen between patient weight and peak enhancement times or values. Mean peak enhancement times for the aorta, main portal vein, and liver were 9-11 s, 18-22 s, and 30-34 s, respectively (p > 0.05). The correlations between injection duration and peak enhancement values were significant and negative. Conclusions: Regardless of patient weight and injection duration, peak enhancement times of aorta, main portal vein and liver were approximately 10, 20, and 30 s, respectively. The enhancement values tended to be higher for shorter injection durations

  14. Fair Value in the light of IFRS 13 «Fair Value Measurement»

    Directory of Open Access Journals (Sweden)

    V.V. Svitselska

    2015-03-01

    Full Text Available The main provisions of IFRS 13 «Fair Value Measurement» have been researched as well as its critical analysis has been conducted. Comparison of the previous and the new definition of the concept «fair value» has been done on the basis of what the shortcomings of the previous definition have been highlighted, the characteristic features and advantages of new definition from IFRS 13 «Fair Value Measurement» have been outlined. It has been proved that new interpretation of the concept of «fair value» is narrower and more accurate than the previous, it clarifies the subject matter, subjects of transactions, as well as the date of its execution. The scheme of estimation at fair value as well as model of fair value determination according to IFRS 13 «Fair Value Measurement» has been presented. Methods of measurement at fair value and the fair value hierarchy have been researched. Some disadvantages of provisions of IFRS 13 «Fair Value Measurement» on the basis of its analysis have been highlighted, uncertainty is essential among them in which fair value should be applied.

  15. PAPR Reduction in OFDM-based Visible Light Communication Systems Using a Combination of Novel Peak-value Feedback Algorithm and Genetic Algorithm

    Science.gov (United States)

    Deng, Honggui; Liu, Yan; Ren, Shuang; He, Hailang; Tang, Chengying

    2017-10-01

    We propose an enhanced partial transmit sequence technique based on novel peak-value feedback algorithm and genetic algorithm (GAPFA-PTS) to reduce peak-to-average power ratio (PAPR) of orthogonal frequency division multiplexing (OFDM) signals in visible light communication (VLC) systems(VLC-OFDM). To demonstrate the advantages of our proposed algorithm, we analyze the flow of proposed technique and compare the performances with other techniques through MATLAB simulation. The results show that GAPFA-PTS technique achieves a significant improvement in PAPR reduction while maintaining low bit error rate (BER) and low complexity in VLC-OFDM systems.

  16. Circuit designs for measuring reactor period, peak power, and pulse fluence on TRIGA and other pulse reactor

    International Nuclear Information System (INIS)

    Meyer, R.D.; Thome, F.V.; Williams, R.L.

    1976-01-01

    Inexpensive circuits for use in evaluating reactor pulse prompt period, peak power, and pulse fluence (NVT) are presented. In addition to low cost, these circuits are easily assembled and calibrated and operate with a high degree of accuracy. The positive period measuring system has been used in evaluating reactivity additions as small as 5 cents (with an accuracy of ±0.1 cents) and as large as $4.50 (accuracy ±2 cents). Reactor peak power is measured digitally with a system accuracy of ±0.04% of a 10 Volt input (±4 mV). The NVT circuit measures over a 2-1/2 decade range, has 3 place resolution and an accuracy of better than 1%. (author)

  17. A simple method for the deconvolution of 134 Cs/137 Cs peaks in gamma-ray scintillation spectrometry

    International Nuclear Information System (INIS)

    Darko, E.O.; Osae, E.K.; Schandorf, C.

    1998-01-01

    A simple method for the deconvolution of 134 Cs / 137 Cs peaks in a given mixture of 134 Cs and 137 Cs using Nal(TI) gamma-ray scintillation spectrometry is described. In this method the 795 keV energy of 134 Cs is used as a reference peak to calculate the activity of the 137 Cs directly from the measured peaks. Certified reference materials were measured using the method and compared with a high resolution gamma-ray spectrometry measurements. The results showed good agreement with the certified values. The method is very simple and does not need any complicated mathematics and computer programme to de- convolute the overlapping 604.7 keV and 661.6 keV peaks of 134 Cs and 137 Cs respectively. (author). 14 refs.; 1 tab., 2 figs

  18. Positive-Operator Valued Measure (POVM Quantization

    Directory of Open Access Journals (Sweden)

    Jean Pierre Gazeau

    2014-12-01

    Full Text Available We present a general formalism for giving a measure space paired with a separable Hilbert space a quantum version based on a normalized positive operator-valued measure. The latter are built from families of density operators labeled by points of the measure space. We especially focus on various probabilistic aspects of these constructions. Simple ormore elaborate examples illustrate the procedure: circle, two-sphere, plane and half-plane. Links with Positive-Operator Valued Measure (POVM quantum measurement and quantum statistical inference are sketched.

  19. Systolic peak detection in acceleration photoplethysmograms measured from emergency responders in tropical conditions.

    Science.gov (United States)

    Elgendi, Mohamed; Norton, Ian; Brearley, Matt; Abbott, Derek; Schuurmans, Dale

    2013-01-01

    Photoplethysmogram (PPG) monitoring is not only essential for critically ill patients in hospitals or at home, but also for those undergoing exercise testing. However, processing PPG signals measured after exercise is challenging, especially if the environment is hot and humid. In this paper, we propose a novel algorithm that can detect systolic peaks under challenging conditions, as in the case of emergency responders in tropical conditions. Accurate systolic-peak detection is an important first step for the analysis of heart rate variability. Algorithms based on local maxima-minima, first-derivative, and slope sum are evaluated, and a new algorithm is introduced to improve the detection rate. With 40 healthy subjects, the new algorithm demonstrates the highest overall detection accuracy (99.84% sensitivity, 99.89% positive predictivity). Existing algorithms, such as Billauer's, Li's and Zong's, have comparable although lower accuracy. However, the proposed algorithm presents an advantage for real-time applications by avoiding human intervention in threshold determination. For best performance, we show that a combination of two event-related moving averages with an offset threshold has an advantage in detecting systolic peaks, even in heat-stressed PPG signals.

  20. Influence of peak exercise heart rate on normal thallium-201 myocardial clearance

    International Nuclear Information System (INIS)

    Kaul, S.; Chesler, D.A.; Pohost, G.M.; Strauss, H.W.; Okada, R.D.; Boucher, C.A.

    1986-01-01

    Measurement of myocardial clearance rates between initial and delayed images is a major justification for adding computer quantification to the interpretation of exercise 201 TI images. To clarify the range of normal thallium clearance and its relationship to the level of exercise achieved, exercise thallium images in 89 normal subjects were analyzed: 45 asymptomatic subjects with less than 1% probability of coronary artery disease (CAD) (Group I), and 44 patients with chest pain found to have no significant CAD on angiography (Group II). Mean initial regional thallium uptake was similar in the two groups, but myocardial thallium clearance (mean +/- 1 s.d.) was slower in Group II, expressed as a longer half-life in the myocardium (8.2 +/- 7.6 hr compared with 3.4 +/- 0.7 hr p less than 0.001). Analysis of variance using ten clinical and exercise variables as covariates showed that the slower clearance in Group II was related to a lower peak exercise heart rate (HR) (154 +/- 27 compared with 183 +/- 11, respectively, p less than 0.001). By linear regression analysis, a decrease in peak HR of 1 beat/min was associated with a slower thallium clearance (longer half-life) of 0.05 hr. Using this formula, the clearance value in each patient was then corrected for peak exercise heart rate by decreasing measured clearance by 0.05 hr multiplied by the amount peak exercise heart rate which was below 183 (the mean value in Group I). There were no differences in the corrected clearance between the two groups. We conclude that thallium myocardial clearance after exercise is related in part to factors other than the presence of CAD, being slower when peak exercise HR is lower. Therefore, thallium clearance rates alone uncorrected for peak exercise heart rate should be used with caution when diagnosing CAD

  1. Peak broadening in paper chromatography and related techniques : III. Peak broadening in thin-layer chromatography on cellulose powder

    NARCIS (Netherlands)

    Ligny, C.L. de; Remijnse, A.G.

    1968-01-01

    The mechanism of peak broadening in thin-layer chromatography on cellulose powder was investigated by comparing the peak widths obtained in chromatography with those caused only by diffusion in the cellulose powder, for a set of amino acids of widely differing RF values and six kinds of cellulose

  2. Measurements of Ion Stopping around the Bragg Peak in High-Energy-Density Plasmas

    Science.gov (United States)

    Frenje, Johan

    2015-11-01

    Over the last few decades, ion stopping in weakly- to strongly-coupled High-Energy-Density (HED) plasmas has been subject to extensive analytical and numerical studies, but only a limited set of experimental data exists to check the validity of these theories. Most of these experiments also did not probe the detailed characteristics of the Bragg peak (peak ion stopping) where the ion velocity is similar to the average thermal electron velocity. To the best of our knowledge, only one exploratory attempt to do this was conducted by Hicks et al., who were able to describe qualitatively the behavior of the Bragg peak for one plasma condition. The work described in this presentation makes significant advances over previous experimental efforts by quantitatively assessing the characteristics of the ion stopping, ranging from low-velocity stopping, through the Bragg peak, to high-velocity stopping for different HED plasma conditions. This was achieved by measuring the energy loss of DD-tritons, D3He-alphas, DD-protons and D3He-protons, with distinctly different velocities, and the results indicate that the stopping power varies strongly with Te and ne. This effort represents the first experimental test of state-of-art plasma-stopping-power theories around the Bragg peak, which is an important first step in our efforts of getting a fundamental understanding of DT-alpha stopping in HED plasmas, a prerequisite for understanding ignition margins in various implosion designs with varying hot spot areal density at the National Ignition Facility. The work described here was performed in part at the LLE National Laser User's Facility (NLUF), and was supported in part by US DOE (Grant No. DE-FG03- 03SF22691), LLNL (subcontract Grant No. B504974) and LLE (subcontract Grant No. 412160-001G).

  3. Measuring Value in Internal Medicine Residency Training Hospitals Using Publicly Reported Measures.

    Science.gov (United States)

    Schickedanz, Adam; Gupta, Reshma; Arora, Vineet M; Braddock, Clarence H

    2018-03-01

    Graduate medical education (GME) lacks measures of resident preparation for high-quality, cost-conscious practice. The authors used publicly reported teaching hospital value measures to compare internal medicine residency programs on high-value care training and to validate these measures against program director perceptions of value. Program-level value training scores were constructed using Centers for Medicare & Medicaid Services Value-Based Purchasing (VBP) Program hospital quality and cost-efficiency data. Correlations with Association of Program Directors in Internal Medicine Annual Survey high-value care training measures were examined using logistic regression. For every point increase in program-level VBP score, residency directors were more likely to agree that GME programs have a responsibility to contain health care costs (adjusted odds ratio [aOR] 1.18, P = .04), their faculty model high-value care (aOR 1.07, P = .03), and residents are prepared to make high-value medical decisions (aOR 1.07, P = .09). Publicly reported clinical data offer valid measures of GME value training.

  4. Calibration of kV measurers with the practical peak voltage (IEC 1676)

    International Nuclear Information System (INIS)

    Becker, Paulo H.B.; Peres, Marcos A.L.; Ludwig, Jaime L.; Chernicharo, Carlos C.

    2002-01-01

    The IEC 1676 standard introduces a new quantity for the measurements of the high voltages applied to the X ray tubes used for diagnosis, the 'Practical Peak Voltage' (PPV). In order to start the introduction of this new quantity in Brazil the National Laboratory for Metrology of Ionizing Radiation has developed a procedure for calibrating measuring instruments in this quantity. This procedure is based in the same set up used for the calibration of the conventional kVp, which consists in a high voltage divider (Dynalyser III from Radcal Corporation), a fast analogue to digital conversion board and a data acquisition software. In order to evaluate this procedure a commercial kVp measure instrument that is able to measure PPV (Universal Diavolt from PTW) was calibrated and the results compared. This work presents a summary of the procedure developed and the results obtained with the comparison. (author)

  5. The correlation between superparamagnetic blocking temperatures and peak temperatures obtained from ac magnetization measurements

    International Nuclear Information System (INIS)

    Madsen, Daniel Esmarch; Moerup, Steen; Hansen, Mikkel Fougt

    2008-01-01

    We study the correlation between the superparamagnetic blocking temperature T B and the peak positions T p observed in ac magnetization measurements for nanoparticles of different classes of magnetic materials. In general, T p = α+βT B . The parameters α and β are different for the in-phase (χ') and out-of-phase (χ'') components and depend on the width σ V of the log-normal volume distribution and the class of magnetic material (ferromagnetic/antiferromagnetic). Consequently, knowledge of both α and β is required if the anisotropy energy barrier KV and the attempt time τ 0 are to be reliably obtained from an analysis based solely on the peak positions

  6. A channel-by-channel method of reducing the errors associated with peak area integration

    International Nuclear Information System (INIS)

    Luedeke, T.P.; Tripard, G.E.

    1996-01-01

    A new method of reducing the errors associated with peak area integration has been developed. This method utilizes the signal content of each channel as an estimate of the overall peak area. These individual estimates can then be weighted according to the precision with which each estimate is known, producing an overall area estimate. Experimental measurements were performed on a small peak sitting on a large background, and the results compared to those obtained from a commercial software program. Results showed a marked decrease in the spread of results around the true value (obtained by counting for a long period of time), and a reduction in the statistical uncertainty associated with the peak area. (orig.)

  7. English Value-Added Measures: Examining the Limitations of School Performance Measurement

    Science.gov (United States)

    Perry, Thomas

    2016-01-01

    Value-added "Progress" measures are to be introduced for all English schools in 2016 as "headline" measures of school performance. This move comes despite research highlighting high levels of instability in value-added measures and concerns about the omission of contextual variables in the planned measure. This article studies…

  8. Quantum measurement with a positive operator-valued measure

    International Nuclear Information System (INIS)

    Brandt, Howard E

    2003-01-01

    In the quantum theory of measurement, the positive operator-valued measure (POVM) is an important concept, and its implementation can be useful. A POVM consists of a set of non-negative quantum-mechanical Hermitian operators that add up to the identity. The probability that a quantum system is in a particular state is given by the expectation value of the POVM operator corresponding to that state. Following a brief review of the mathematics and mention of the history of POVMs in quantum theory, a particular implementation of a POVM for use in the measurement of nonorthogonal photon polarization states is reviewed. The implementation consists simply of a Wollaston prism, a mirror, two beam splitters, a polarization rotator and three phototubes arranged in an interferometric configuration, and it is shown analytically that the device faithfully represents the POVM. Based on Neumark's extension theorem, the two-dimensional Hilbert space of the POVM implementation can be embedded in the three-dimensional Hilbert space of an ordinary projective-valued measure. Also, analytical expressions are given for the maximum Renyi information loss from the device to a disturbing probe, and for the error and inconclusive rates induced by the probe. Various aspects of the problem of probe optimization are elaborated

  9. Time-varying value of electric energy efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Mims, Natalie A.; Eckman, Tom; Goldman, Charles

    2017-06-30

    Electric energy efficiency resources save energy and may reduce peak demand. Historically, quantification of energy efficiency benefits has largely focused on the economic value of energy savings during the first year and lifetime of the installed measures. Due in part to the lack of publicly available research on end-use load shapes (i.e., the hourly or seasonal timing of electricity savings) and energy savings shapes, consideration of the impact of energy efficiency on peak demand reduction (i.e., capacity savings) has been more limited. End-use load research and the hourly valuation of efficiency savings are used for a variety of electricity planning functions, including load forecasting, demand-side management and evaluation, capacity and demand response planning, long-term resource planning, renewable energy integration, assessing potential grid modernization investments, establishing rates and pricing, and customer service. This study reviews existing literature on the time-varying value of energy efficiency savings, provides examples in four geographically diverse locations of how consideration of the time-varying value of efficiency savings impacts the calculation of power system benefits, and identifies future research needs to enhance the consideration of the time-varying value of energy efficiency in cost-effectiveness screening analysis. Findings from this study include: -The time-varying value of individual energy efficiency measures varies across the locations studied because of the physical and operational characteristics of the individual utility system (e.g., summer or winter peaking, load factor, reserve margin) as well as the time periods during which savings from measures occur. -Across the four locations studied, some of the largest capacity benefits from energy efficiency are derived from the deferral of transmission and distribution system infrastructure upgrades. However, the deferred cost of such upgrades also exhibited the greatest range

  10. FAIR VALUE MEASUREMENT UNDER IFRS 13

    Directory of Open Access Journals (Sweden)

    COZMA IGHIAN DIANA

    2015-07-01

    Full Text Available The IFRS 13, „Fair Value Measurement”, was first published in May 2011 and it applies to annual reporting periods that begin on or after January 1st 2013; this standard comes as a result of shared efforts on the part of the IASB and the FASB to develop a convergent framework regarding fair value measurement. The main purpose of this paper is to describe the main provisions of the IFRS 13 regarding fair value measurement, with a special emphasis on key concepts found throughout the standard, which refer to the principal market, the most advantageous market, the highest and best use, valuation techniques, and value hierarchy.

  11. Isotope resolution of the iron peak

    International Nuclear Information System (INIS)

    Henke, R.P.; Benton, E.V.

    1977-01-01

    A stack of Lexan detectors from the Apollo 17 mission has been analyzed to obtain Z measurements of sufficient accuracy to resolve the iron peak into its isotopic components. Within this distribution several peaks are present. With the centrally located, most populated peak assumed to be 56 Fe, the measurements imply that the abundances of 54 Fe and 58 Fe are appreciable fractions of the 56 Fe abundance. This result is in agreement with those of Webber et al. and Siegman et al. but in disagreement with the predictions of Tsao et al. (Auth.)

  12. An Empirical Study on Raman Peak Fitting and Its Application to Raman Quantitative Research.

    Science.gov (United States)

    Yuan, Xueyin; Mayanovic, Robert A

    2017-10-01

    Fitting experimentally measured Raman bands with theoretical model profiles is the basic operation for numerical determination of Raman peak parameters. In order to investigate the effects of peak modeling using various algorithms on peak fitting results, the representative Raman bands of mineral crystals, glass, fluids as well as the emission lines from a fluorescent lamp, some of which were measured under ambient light whereas others under elevated pressure and temperature conditions, were fitted using Gaussian, Lorentzian, Gaussian-Lorentzian, Voigtian, Pearson type IV, and beta profiles. From the fitting results of the Raman bands investigated in this study, the fitted peak position, intensity, area and full width at half-maximum (FWHM) values of the measured Raman bands can vary significantly depending upon which peak profile function is used in the fitting, and the most appropriate fitting profile should be selected depending upon the nature of the Raman bands. Specifically, the symmetric Raman bands of mineral crystals and non-aqueous fluids are best fit using Gaussian-Lorentzian or Voigtian profiles, whereas the asymmetric Raman bands are best fit using Pearson type IV profiles. The asymmetric O-H stretching vibrations of H 2 O and the Raman bands of soda-lime glass are best fit using several Gaussian profiles, whereas the emission lines from a florescent light are best fit using beta profiles. Multiple peaks that are not clearly separated can be fit simultaneously, provided the residuals in the fitting of one peak will not affect the fitting of the remaining peaks to a significant degree. Once the resolution of the Raman spectrometer has been properly accounted for, our findings show that the precision in peak position and intensity can be improved significantly by fitting the measured Raman peaks with appropriate profiles. Nevertheless, significant errors in peak position and intensity were still observed in the results from fitting of weak and wide Raman

  13. VALUATION TECHNIQUES USED IN FAIR VALUE MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Cristina-Aurora, BUNEA-BONTAS

    2013-12-01

    Full Text Available Valuation of assets and liabilities involves significant judgements and estimates, especially when fair value measurement is required. Currently, IFRS 13 Fair Value Measurement offers a single and more comprehensive source of guidance that is applied to almost all fair value estimates. When measuring fair value of fixed assets, intangible assets, specified financial assets or liabilities, different valuation techniques may be used: the market approach, the cost approach and the income approach. This article reviews these techniques and points out that different valuation practices may provide different results depending on the item being fair valued and on the inputs used. Also it emphasizes that, in particular circumstances, there is the possibility that a certain technique may be more appropriate than other.

  14. Measuring the value of intangibles

    DEFF Research Database (Denmark)

    Clausen, Saskia; Hirth, Stefan

    2016-01-01

    We propose a new earnings-based measure for the value of intangibles. To validate this measure, we compare it to commonly used proxies for intangible intensity, such as R&D expenses. While R&D expenses measure the investment in new intangibles, our new measure gauges the productivity of already e...... of our intangible-intensity measure in the context of capital structure. We find that more intangible-intensive firms have lower leverage. © 2016 Elsevier B.V....

  15. Estimations of One Repetition Maximum and Isometric Peak Torque in Knee Extension Based on the Relationship Between Force and Velocity.

    Science.gov (United States)

    Sugiura, Yoshito; Hatanaka, Yasuhiko; Arai, Tomoaki; Sakurai, Hiroaki; Kanada, Yoshikiyo

    2016-04-01

    We aimed to investigate whether a linear regression formula based on the relationship between joint torque and angular velocity measured using a high-speed video camera and image measurement software is effective for estimating 1 repetition maximum (1RM) and isometric peak torque in knee extension. Subjects comprised 20 healthy men (mean ± SD; age, 27.4 ± 4.9 years; height, 170.3 ± 4.4 cm; and body weight, 66.1 ± 10.9 kg). The exercise load ranged from 40% to 150% 1RM. Peak angular velocity (PAV) and peak torque were used to estimate 1RM and isometric peak torque. To elucidate the relationship between force and velocity in knee extension, the relationship between the relative proportion of 1RM (% 1RM) and PAV was examined using simple regression analysis. The concordance rate between the estimated value and actual measurement of 1RM and isometric peak torque was examined using intraclass correlation coefficients (ICCs). Reliability of the regression line of PAV and % 1RM was 0.95. The concordance rate between the actual measurement and estimated value of 1RM resulted in an ICC(2,1) of 0.93 and that of isometric peak torque had an ICC(2,1) of 0.87 and 0.86 for 6 and 3 levels of load, respectively. Our method for estimating 1RM was effective for decreasing the measurement time and reducing patients' burden. Additionally, isometric peak torque can be estimated using 3 levels of load, as we obtained the same results as those reported previously. We plan to expand the range of subjects and examine the generalizability of our results.

  16. A method for estimating peak and time of peak streamflow from excess rainfall for 10- to 640-acre watersheds in the Houston, Texas, metropolitan area

    Science.gov (United States)

    Asquith, William H.; Cleveland, Theodore G.; Roussel, Meghan C.

    2011-01-01

    Estimates of peak and time of peak streamflow for small watersheds (less than about 640 acres) in a suburban to urban, low-slope setting are needed for drainage design that is cost-effective and risk-mitigated. During 2007-10, the U.S. Geological Survey (USGS), in cooperation with the Harris County Flood Control District and the Texas Department of Transportation, developed a method to estimate peak and time of peak streamflow from excess rainfall for 10- to 640-acre watersheds in the Houston, Texas, metropolitan area. To develop the method, 24 watersheds in the study area with drainage areas less than about 3.5 square miles (2,240 acres) and with concomitant rainfall and runoff data were selected. The method is based on conjunctive analysis of rainfall and runoff data in the context of the unit hydrograph method and the rational method. For the unit hydrograph analysis, a gamma distribution model of unit hydrograph shape (a gamma unit hydrograph) was chosen and parameters estimated through matching of modeled peak and time of peak streamflow to observed values on a storm-by-storm basis. Watershed mean or watershed-specific values of peak and time to peak ("time to peak" is a parameter of the gamma unit hydrograph and is distinct from "time of peak") of the gamma unit hydrograph were computed. Two regression equations to estimate peak and time to peak of the gamma unit hydrograph that are based on watershed characteristics of drainage area and basin-development factor (BDF) were developed. For the rational method analysis, a lag time (time-R), volumetric runoff coefficient, and runoff coefficient were computed on a storm-by-storm basis. Watershed-specific values of these three metrics were computed. A regression equation to estimate time-R based on drainage area and BDF was developed. Overall arithmetic means of volumetric runoff coefficient (0.41 dimensionless) and runoff coefficient (0.25 dimensionless) for the 24 watersheds were used to express the rational

  17. Study of the peak shape in alpha spectra measured by liquid scintillation

    CERN Document Server

    Vera-Tome, F; Martin-Sanchez, A

    2002-01-01

    Liquid-scintillation counting allows the measurement of alpha and beta activities jointly or only of the alpha-emitting nuclides in a sample. Although the resolution of the alpha spectra is poorer than that attained with semiconductor detectors, it is still an attractive alternative. We describe here attempts to fit a peak shape to experimental liquid-scintillation alpha spectra and discuss the parameters affecting this shape, such as the PSA (pulse-shape analyser) level, vial type, shaking the sample, etc. Spectral analysis has been applied for complex alpha spectra.

  18. Some predicted peak ground motions for nuclear cratering explosions along the Qattara alignment in Egypt

    International Nuclear Information System (INIS)

    Bryan, J.B.

    1980-01-01

    Some predicted peak free-field ground motions at shot depth for the nuclear explosive excavation of a canal in Egypt are summarized. Peak values of displacement, velocity, acceleration, and radial stress are presented as a function of slant range from the working point. Results from two-dimensional TENSOR cratering calculations are included. Fits to ground motion measurements in other media are also shown. This summary is intended to help specify engineering design requirements for detonating nuclear explosive salvos which are required to efficiently excavate the canal. It also should be useful in guiding estimates for gage response ranges in ground motion measurements

  19. Reduction of chemical formulas from the isotopic peak distributions of high-resolution mass spectra.

    Science.gov (United States)

    Roussis, Stilianos G; Proulx, Richard

    2003-03-15

    A method has been developed for the reduction of the chemical formulas of compounds in complex mixtures from the isotopic peak distributions of high-resolution mass spectra. The method is based on the principle that the observed isotopic peak distribution of a mixture of compounds is a linear combination of the isotopic peak distributions of the individual compounds in the mixture. All possible chemical formulas that meet specific criteria (e.g., type and number of atoms in structure, limits of unsaturation, etc.) are enumerated, and theoretical isotopic peak distributions are generated for each formula. The relative amount of each formula is obtained from the accurately measured isotopic peak distribution and the calculated isotopic peak distributions of all candidate formulas. The formulas of compounds in simple spectra, where peak components are fully resolved, are rapidly determined by direct comparison of the calculated and experimental isotopic peak distributions. The singular value decomposition linear algebra method is used to determine the contributions of compounds in complex spectra containing unresolved peak components. The principles of the approach and typical application examples are presented. The method is most useful for the characterization of complex spectra containing partially resolved peaks and structures with multiisotopic elements.

  20. Analysis of Peak-to-Peak Current Ripple Amplitude in Seven-Phase PWM Voltage Source Inverters

    Directory of Open Access Journals (Sweden)

    Gabriele Grandi

    2013-08-01

    Full Text Available Multiphase systems are nowadays considered for various industrial applications. Numerous pulse width modulation (PWM schemes for multiphase voltage source inverters with sinusoidal outputs have been developed, but no detailed analysis of the impact of these modulation schemes on the output peak-to-peak current ripple amplitude has been reported. Determination of current ripple in multiphase PWM voltage source inverters is important for both design and control purposes. This paper gives the complete analysis of the peak-to-peak current ripple distribution over a fundamental period for multiphase inverters, with particular reference to seven-phase VSIs. In particular, peak-to-peak current ripple amplitude is analytically determined as a function of the modulation index, and a simplified expression to get its maximum value is carried out. Although reference is made to the centered symmetrical PWM, being the most simple and effective solution to maximize the DC bus utilization, leading to a nearly-optimal modulation to minimize the RMS of the current ripple, the analysis can be readily extended to either discontinuous or asymmetrical modulations, both carrier-based and space vector PWM. A similar approach can be usefully applied to any phase number. The analytical developments for all different sub-cases are verified by numerical simulations.

  1. Analysis of factors influencing the integrated bolus peak timing in contrast-enhanced brain computed tomographic angiography

    International Nuclear Information System (INIS)

    Son, Soon Yong; Choi, Kwan Woo; Jeong, Hoi Woun; Jang, Seo Goo; Jung, Jae Young; Yun, Jung Soo; Kim, Ki Won; Lee, Young Ah; Son, Jin Hyun; Min, Jung Whan

    2016-01-01

    The objective of this study was to analyze the factors influencing integrated bolus peak timing in contrast- enhanced computed tomographic angiography (CTA) and to determine a method of calculating personal peak time. The optimal time was calculated by performing multiple linear regression analysis, after finding the influence factors through correlation analysis between integrated peak time of contrast medium and personal measured value by monitoring CTA scans. The radiation exposure dose in CTA was 716.53 mGy·cm and the radiation exposure dose in monitoring scan was 15.52 mGy (2 - 34 mGy). The results were statistically significant (p < .01). Regression analysis revealed, a -0.160 times decrease with a one-step increase in heart rate in male, and -0.004, -0.174, and 0.006 times decrease with one-step in DBP, heart rate, and blood sugar, respectively, in female. In a consistency test of peak time by calculating measured peak time and peak time by using the regression equation, the consistency was determined to be very high for male and female. This study could prevent unnecessary dose exposure by encouraging in clinic calculation of personal integrated peak time of contrast medium prior to examination

  2. The U.S. Geological Survey Peak-Flow File Data Verification Project, 2008–16

    Science.gov (United States)

    Ryberg, Karen R.; Goree, Burl B.; Williams-Sether, Tara; Mason, Robert R.

    2017-11-21

    measured as of November 19, 2008 (before the automated scripts were widely applied) and on November 14, 2016 (after several rounds of corrections). There were 659,332 peak-flow values in the 2008 dataset and 731,965 peak-flow values in the 2016 dataset. When compared to the 2016 dataset, 5,179 (0.79 percent) peak-flow values had changed; 36,506 (5.54 percent) of the peak-flow qualification codes had changed; 1,938 (0.29 percent) peak-flow dates had changed; 18,599 (2.82 percent) of the peak-flow gage heights had changed; and 20,683 (3.14 percent) of the gage-height qualification codes had changed—most as a direct result of the peak-flow file data verification effort led by USGS personnel. The various types of changes are summarized and mapped in this report. In addition to this report, a corresponding USGS data release is provided to identify changes in peak flows at individual streamgages. The data release and the procedures to access the data release are described in this report.

  3. Measurement of peak temperature along an optical fiber

    International Nuclear Information System (INIS)

    Fox, R.J.

    1983-01-01

    A multimode silica-clad optical fiber with a liquid silicone core was used as a distributed-line peak-temperature sensor over a temperature range from ambient to 190 0 C. The maximum error was 2 0 C and was essentially independent of the length or position of the hot zone

  4. Evaluation of concurrent peak responses

    International Nuclear Information System (INIS)

    Wang, P.C.; Curreri, J.; Reich, M.

    1983-01-01

    This report deals with the problem of combining two or more concurrent responses which are induced by dynamic loads acting on nuclear power plant structures. Specifically, the acceptability of using the square root of the sum of the squares (SRSS) value of peak values as the combined response is investigated. Emphasis is placed on the establishment of a simplified criterion that is convenient and relatively easy to use by design engineers

  5. Development of the modified sum-peak method and its application

    International Nuclear Information System (INIS)

    Ogata, Y.; Miyahara, H.; Ishihara, M.; Ishigure, N.; Yamamoto, S.; Kojima, S.

    2016-01-01

    As the sum-peak method requires the total count rate as well as the peak count rates and the sum peak count rate, this meets difficulties when a sample contains other radionuclides than the one to be measured. To solve the problem, a new method using solely the peak and the sum peak count rates was developed. The method was theoretically and experimentally confirmed using "6"0Co, "2"2Na and "1"3"4Cs. We demonstrate that the modified sum-peak method is quite simple and practical and is useful to measure multiple nuclides. - Highlights: • A modified sum-peak method for simple radioactivity measurement was developed. • The method solely requires the peak count rates and the sum peak count rate. • The method is applicable to multiple radionuclides.

  6. Peak expiratory flow rate in healthy rural school going children (5-16 years) of bellur region for construction of nomogram.

    Science.gov (United States)

    Cb, Manjunath; Sc, Kotinatot; Babu, Manjunatha

    2013-12-01

    Peak Expiratory Flow Rate (PEFR) recording is an essential measure in the management and evaluation of asthmatic children.It is helpful in monitoring disease progression and response to treatment. The PEFR can be measured by a simple instrument-peak expiratory flow meter. To construct nomogram of PEFR in healthy rural school going children from Mandya district of Karnataka state, India and to use these nomograms for comparison with that of children with obstructive lung diseases for this region. The study was conducted on Healthy rural school going children, both boys and girls between the age group of 5-16 years. For the determination of PEFR we used Mini Wright Peak Flow Meter. At three time measurement, the highest value of PEFR was recorded. Formula for prediction of PEFR was estimated by linear regression analysis after the correlation of PEFR with age and height for both boys and girls. PEFR was measured in 1028 children aged 5 to 16 years by using Wright's mini peak flow meter. Prediction equations were derived for PEFR with height in boys and girls. Normograms were plotted based on the observed values of PEFR in the study population. Significant linear correlation was seen of PEFR with height in boys (paffected by regional, environmental and anthropometric factors. Hence, it is necessary to have regional reference values for children. Among different factors affecting PEFR, height correlates better with PEFR than weight and sex. Hence nomograms constructed can be used for this region.

  7. KiDS-450: cosmological constraints from weak lensing peak statistics - I. Inference from analytical prediction of high signal-to-noise ratio convergence peaks

    Science.gov (United States)

    Shan, HuanYuan; Liu, Xiangkun; Hildebrandt, Hendrik; Pan, Chuzhong; Martinet, Nicolas; Fan, Zuhui; Schneider, Peter; Asgari, Marika; Harnois-Déraps, Joachim; Hoekstra, Henk; Wright, Angus; Dietrich, Jörg P.; Erben, Thomas; Getman, Fedor; Grado, Aniello; Heymans, Catherine; Klaes, Dominik; Kuijken, Konrad; Merten, Julian; Puddu, Emanuella; Radovich, Mario; Wang, Qiao

    2018-02-01

    This paper is the first of a series of papers constraining cosmological parameters with weak lensing peak statistics using ˜ 450 deg2 of imaging data from the Kilo Degree Survey (KiDS-450). We measure high signal-to-noise ratio (SNR: ν) weak lensing convergence peaks in the range of 3 < ν < 5, and employ theoretical models to derive expected values. These models are validated using a suite of simulations. We take into account two major systematic effects, the boost factor and the effect of baryons on the mass-concentration relation of dark matter haloes. In addition, we investigate the impacts of other potential astrophysical systematics including the projection effects of large-scale structures, intrinsic galaxy alignments, as well as residual measurement uncertainties in the shear and redshift calibration. Assuming a flat Λ cold dark matter model, we find constraints for S_8=σ _8(Ω _m/0.3)^{0.5}=0.746^{+0.046}_{-0.107} according to the degeneracy direction of the cosmic shear analysis and Σ _8=σ _8(Ω _m/0.3)^{0.38}=0.696^{+0.048}_{-0.050} based on the derived degeneracy direction of our high-SNR peak statistics. The difference between the power index of S8 and in Σ8 indicates that combining cosmic shear with peak statistics has the potential to break the degeneracy in σ8 and Ωm. Our results are consistent with the cosmic shear tomographic correlation analysis of the same data set and ˜2σ lower than the Planck 2016 results.

  8. Corporate performance and the measures of value added

    Directory of Open Access Journals (Sweden)

    T. Petravičius

    2008-09-01

    Full Text Available In recent years, managers have turned their attention to the ways increasing the value of their companies. A number of competing measures have been developed and marketed by investment and consulting firms. This paper considers the ways in which value can be created or destroyed in a firm and looks at how to calculate the cost of capital used to measure the opportunity cost of investing funds in one particular business instead of others with equivalent risk. Next, we have a look at the four most widely used value enhancement measures including Economic Value Added, Cash Flow Return on Investment, Market Value Added, Cash Value Added and use an example to think of where these approaches yield similar results and where differences might occur. In conclusion, we summarize the new or unique points in these competing measures, establish the information they can give and explain how to use it when managing and creating shareholder value.

  9. R-values

    International Nuclear Information System (INIS)

    Roberts, K.

    2009-01-01

    I'll try to keep this short and simple. R LANL = (beta cpm of X exp on system 'A')/ (beta cpm of 99 Mo exp on system 'A')/ (beta cpm of X on system 'A', from thermal on 235 U)/ (beta cpm of 99 Mo on system 'A', from thermal on 235 U). As I understand it, the above equation is the historical (as well as current) way of determining R-values using data from beta counting at LANL. The ratio in the denominator, a little 'r', is the 'baseline' or 'calibration' value for a specific beta detector. Over time, if the detector 'drifts' one would see a variation in this 'r' during a thermal calibration measurement. This baseline is what LANL likes to track to monitor specific detector performance - this is not relevant to LLNL where gamma detection is used for determining R-values. LANL states that uncertainty is only dependent upon the count statistics for the isotopes measured. If one tries to convert this to an atom basis, the uncertainties will increase due to the incorporation of the uncertainties in the nuclear data used to convert the cpm to atoms. LLNL switched to gamma detection methods in the 1970s thus replacing our beta counting effort. The equation below is how we have since determined R-values. The numerator ratios atom values of isotopes that are determined by measuring gamma cpm (usually? using several peaks per isotope) and then converting to particle decay in dpm using detector efficiency for each peak and the appropriate branch ratio for each gamma emission. Isotope decay is then converted to atoms using specific activity, mass or volume?, and Avogadro's number. The denominator is simply the ratio of published, cumulative fission product chain yields for isotopes produced in a thermal irradiation on 235U - values of England and Ryder are used by LLNL for the NTNF program. Uncertainties in LLNL R-values are dependent upon gamma counting statistics as well as the nuclear data for each isotope. R LLNL = (Atoms of X exp )/(Atoms of 99 Mo exp )/(Cumulative

  10. Resonant tunneling with high peak to valley current ratio in SiO2/nc-Si/SiO2 multi-layers at room temperature

    International Nuclear Information System (INIS)

    Chen, D. Y.; Sun, Y.; He, Y. J.; Xu, L.; Xu, J.

    2014-01-01

    We have investigated carrier transport in SiO 2 /nc-Si/SiO 2 multi-layers by room temperature current-voltage measurements. Resonant tunneling signatures accompanied by current peaks are observed. Carrier transport in the multi-layers were analyzed by plots of ln(I/V 2 ) as a function of 1/V and ln(I) as a function of V 1/2 . Results suggest that besides films quality, nc-Si and barrier sub-layer thicknesses are important parameters that restrict carrier transport. When thicknesses are both small, direct tunneling dominates carrier transport, resonant tunneling occurs only at certain voltages and multi-resonant tunneling related current peaks can be observed but with peak to valley current ratio (PVCR) values smaller than 1.5. When barrier thickness is increased, trap-related and even high field related tunneling is excited, causing that multi-current peaks cannot be observed clearly, only one current peak with higher PVCR value of 7.7 can be observed. While if the thickness of nc-Si is large enough, quantum confinement is not so strong, a broad current peak with PVCR value as high as 60 can be measured, which may be due to small energy difference between the splitting energy levels in the quantum dots of nc-Si. Size distribution in a wide range may cause un-controllability of the peak voltages

  11. Measuring value sensitivity in medicine.

    Science.gov (United States)

    Ineichen, Christian; Christen, Markus; Tanner, Carmen

    2017-01-28

    Value sensitivity - the ability to recognize value-related issues when they arise in practice - is an indispensable competence for medical practitioners to enter decision-making processes related to ethical questions. However, the psychological competence of value sensitivity is seldom an explicit subject in the training of medical professionals. In this contribution, we outline the traditional concept of moral sensitivity in medicine and its revised form conceptualized as value sensitivity and we propose an instrument that measures value sensitivity. We developed an instrument for assessing the sensitivity for three value groups (moral-related values, values related to the principles of biomedical ethics, strategy-related values) in a four step procedure: 1) value identification (n = 317); 2) value representation (n = 317); 3) vignette construction and quality evaluation (n = 37); and 4) instrument validation by comparing nursing professionals with hospital managers (n = 48). We find that nursing professionals recognize and ascribe importance to principle-related issues more than professionals from hospital management. The latter are more likely to recognize and ascribe importance to strategy-related issues. These hypothesis-driven results demonstrate the discriminatory power of our newly developed instrument, which makes it useful not only for health care professionals in practice but for students and people working in the clinical context as well.

  12. A Framework for Measuring Low-Value Care.

    Science.gov (United States)

    Miller, George; Rhyan, Corwin; Beaudin-Seiler, Beth; Hughes-Cromwick, Paul

    2018-04-01

    It has been estimated that more than 30% of health care spending in the United States is wasteful, and that low-value care, which drives up costs unnecessarily while increasing patient risk, is a significant component of wasteful spending. To address the need for an ability to measure the magnitude of low-value care nationwide, identify the clinical services that are the greatest contributors to waste, and track progress toward eliminating low-value use of these services. Such an ability could provide valuable input to the efforts of policymakers and health systems to improve efficiency. We reviewed existing methods that could contribute to measuring low-value care and developed an integrated framework that combines multiple methods to comprehensively estimate and track the magnitude and principal sources of clinical waste. We also identified a process and needed research for implementing the framework. A comprehensive methodology for measuring and tracking low-value care in the United States would provide an important contribution toward reducing waste. Implementation of the framework described in this article appears feasible, and the proposed research program will allow moving incrementally toward full implementation while providing a near-term capability for measuring low-value care that can be enhanced over time. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  13. Measuring Values in Environmental Research: A Test of an Environmental Portrait Value Questionnaire

    Science.gov (United States)

    Bouman, Thijs; Steg, Linda; Kiers, Henk A. L.

    2018-01-01

    Four human values are considered to underlie individuals’ environmental beliefs and behaviors: biospheric (i.e., concern for environment), altruistic (i.e., concern for others), egoistic (i.e., concern for personal resources) and hedonic values (i.e., concern for pleasure and comfort). These values are typically measured with an adapted and shortened version of the Schwartz Value Survey (SVS), to which we refer as the Environmental-SVS (E-SVS). Despite being well-validated, recent research has indicated some concerns about the SVS methodology (e.g., comprehensibility, self-presentation biases) and suggested an alternative method of measuring human values: The Portrait Value Questionnaire (PVQ). However, the PVQ has not yet been adapted and applied to measure values most relevant to understand environmental beliefs and behaviors. Therefore, we tested the Environmental-PVQ (E-PVQ) – a PVQ variant of E-SVS –and compared it with the E-SVS in two studies. Our findings provide strong support for the validity and reliability of both the E-SVS and E-PVQ. In addition, we find that respondents slightly preferred the E-PVQ over the E-SVS (Study 1). In general, both scales correlate similarly to environmental self-identity (Study 1), energy behaviors (Studies 1 and 2), pro-environmental personal norms, climate change beliefs and policy support (Study 2). Accordingly, both methodologies show highly similar results and seem well-suited for measuring human values underlying environmental behaviors and beliefs. PMID:29743874

  14. The additional value of first pass myocardial perfusion imaging during peak dose of dobutamine stress cardiac MRI for the detection of myocardial ischemia

    NARCIS (Netherlands)

    Lubbers, Daniel D.; Janssen, Caroline H. C.; Kuijpers, Dirkjan; Van Dijkman, Paul R. M.; Overbosch, Jelle; Willems, Tineke P.; Oudkerk, Matthijs

    Purpose of this study was to assess the additional value of first pass myocardial perfusion imaging during peak dose of dobutamine stress Cardiac-MR (CMR). Dobutamine Stress CMR was performed in 115 patients with an inconclusive diagnosis of myocardial ischemia on a 1.5 T system (Magnetom Avanto,

  15. Measuring values for cross-cultural research

    NARCIS (Netherlands)

    Maseland, R.K.J.; Hoorn, A.A.J. van

    2009-01-01

    This paper investigates the empirical relevance of the recent critique that values surveys, as they are, suffer from the problem of measuring marginal preferences rather than values. By surveying items from cross-cultural surveys by Hofstede, Inglehart and GLOBE, we show that the marginal

  16. QRS peak detection for heart rate monitoring on Android smartphone

    Science.gov (United States)

    Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto

    2017-11-01

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.

  17. Employer Attitudes towards Peak Hour Avoidance

    NARCIS (Netherlands)

    Vonk Noordegraaf, D.M.; Annema, J.A.

    2012-01-01

    Peak Hour Avoidance is a relatively new Dutch mobility management measure. To reduce congestion frequent car drivers are given a financial reward for reducing the proportion of trips that they make during peak hours on a specific motorway section. Although previous studies show that employers are

  18. Employer attitudes towards peak hour avoidance

    NARCIS (Netherlands)

    Noordegraaf, D.M.V.; Annema, J.A.

    2012-01-01

    Peak Hour Avoidance is a relatively new Dutch mobility management measure. To reduce congestion frequent car drivers are given a financial reward for reducing the proportion of trips that they make during peak hours on a specific motorway section. Although previous studies show that employers are

  19. Local properties of the large-scale peaks of the CMB temperature

    Energy Technology Data Exchange (ETDEWEB)

    Marcos-Caballero, A.; Martínez-González, E.; Vielva, P., E-mail: marcos@ifca.unican.es, E-mail: martinez@ifca.unican.es, E-mail: vielva@ifca.unican.es [Instituto de Física de Cantabria, CSIC-Universidad de Cantabria, Avda. de los Castros s/n, 39005 Santander (Spain)

    2017-05-01

    In the present work, we study the largest structures of the CMB temperature measured by Planck in terms of the most prominent peaks on the sky, which, in particular, are located in the southern galactic hemisphere. Besides these large-scale features, the well-known Cold Spot anomaly is included in the analysis. All these peaks would contribute significantly to some of the CMB large-scale anomalies, as the parity and hemispherical asymmetries, the dipole modulation, the alignment between the quadrupole and the octopole, or in the case of the Cold Spot, to the non-Gaussianity of the field. The analysis of the peaks is performed by using their multipolar profiles, which characterize the local shape of the peaks in terms of the discrete Fourier transform of the azimuthal angle. In order to quantify the local anisotropy of the peaks, the distribution of the phases of the multipolar profiles is studied by using the Rayleigh random walk methodology. Finally, a direct analysis of the 2-dimensional field around the peaks is performed in order to take into account the effect of the galactic mask. The results of the analysis conclude that, once the peak amplitude and its first and second order derivatives at the centre are conditioned, the rest of the field is compatible with the standard model. In particular, it is observed that the Cold Spot anomaly is caused by the large value of curvature at the centre.

  20. Measuring industrial energy efficiency: Physical volume versus economic value

    Energy Technology Data Exchange (ETDEWEB)

    Freeman, S.L.; Niefer, M.J.; Roop, J.M.

    1996-12-01

    This report examines several different measures of industrial output for use in constructing estimates of industrial energy efficiency and discusses some reasons for differences between the measures. Estimates of volume-based measures of output, as well as 3 value-based measures of output (value of production, value of shipments, and value added), are evaluated for 15 separate 4-digit industries. Volatility, simple growth rate, and trend growth rate estimates are made for each industry and each measure of output. Correlations are made between the volume- and value-based measures of output. Historical energy use data are collected for 5 of the industries for making energy- intensity estimates. Growth rates in energy use, energy intensity, and correlations between volume- and value-based measures of energy intensity are computed. There is large variability in growth trend estimates both long term and from year to year. While there is a high correlation between volume- and value-based measures of output for a few industries, typically the correlation is low, and this is exacerbated for estimates of energy intensity. Analysis revealed reasons for these low correlations. It appears that substantial work must be done before reliable measures of trends in the energy efficiency of industry can be accurately characterized.

  1. An Automated Measurement of Ciliary Beating Frequency using a Combined Optical Flow and Peak Detection.

    Science.gov (United States)

    Kim, Woojae; Han, Tae Hwa; Kim, Hyun Jun; Park, Man Young; Kim, Ku Sang; Park, Rae Woong

    2011-06-01

    The mucociliary transport system is a major defense mechanism of the respiratory tract. The performance of mucous transportation in the nasal cavity can be represented by a ciliary beating frequency (CBF). This study proposes a novel method to measure CBF by using optical flow. To obtain objective estimates of CBF from video images, an automated computer-based image processing technique is developed. This study proposes a new method based on optical flow for image processing and peak detection for signal processing. We compare the measuring accuracy of the method in various combinations of image processing (optical flow versus difference image) and signal processing (fast Fourier transform [FFT] vs. peak detection [PD]). The digital high-speed video method with a manual count of CBF in slow motion video play, is the gold-standard in CBF measurement. We obtained a total of fifty recorded ciliated sinonasal epithelium images to measure CBF from the Department of Otolaryngology. The ciliated sinonasal epithelium images were recorded at 50-100 frames per second using a charge coupled device camera with an inverted microscope at a magnification of ×1,000. The mean square errors and variance for each method were 1.24, 0.84 Hz; 11.8, 2.63 Hz; 3.22, 1.46 Hz; and 3.82, 1.53 Hz for optical flow (OF) + PD, OF + FFT, difference image [DI] + PD, and DI + FFT, respectively. Of the four methods, PD using optical flow showed the best performance for measuring the CBF of nasal mucosa. The proposed method was able to measure CBF more objectively and efficiently than what is currently possible.

  2. THE ISSUES IN THE MEASUREMENT OF POSTMATERIAL VALUES

    Directory of Open Access Journals (Sweden)

    Svetlana Tasić

    2012-02-01

    Full Text Available The measurement of postmaterial values includes measuring of the views on the preservation ofpeace, freedom of speech, environmental protection, tolerance and everything else that is contrary tothe concept of measuring the material values, that is physical and economic variables. Measurementof postmaterial values is based on the application of 4 or 12 items scale that refers to the materialismor postmaterialism in certain country. There are several issues and limitations in the application ofpostmaterial values measurement scale which can cause significant error, in other words bias inmeasurement. One of the most interesting issues is the impact of question order change on themeasurement results of postmaterial values. Using the results of empirical research it is shown thatthis effect is significant and, also it is particularly examined the intensity of this effect consideringgender and level of education based on the sample of respondents from urban Serbia.

  3. Automatic Locking of Laser Frequency to an Absorption Peak

    Science.gov (United States)

    Koch, Grady J.

    2006-01-01

    An electronic system adjusts the frequency of a tunable laser, eventually locking the frequency to a peak in the optical absorption spectrum of a gas (or of a Fabry-Perot cavity that has an absorption peak like that of a gas). This system was developed to enable precise locking of the frequency of a laser used in differential absorption LIDAR measurements of trace atmospheric gases. This system also has great commercial potential as a prototype of means for precise control of frequencies of lasers in future dense wavelength-division-multiplexing optical communications systems. The operation of this system is completely automatic: Unlike in the operation of some prior laser-frequency-locking systems, there is ordinarily no need for a human operator to adjust the frequency manually to an initial value close enough to the peak to enable automatic locking to take over. Instead, this system also automatically performs the initial adjustment. The system (see Figure 1) is based on a concept of (1) initially modulating the laser frequency to sweep it through a spectral range that includes the desired absorption peak, (2) determining the derivative of the absorption peak with respect to the laser frequency for use as an error signal, (3) identifying the desired frequency [at the very top (which is also the middle) of the peak] as the frequency where the derivative goes to zero, and (4) thereafter keeping the frequency within a locking range and adjusting the frequency as needed to keep the derivative (the error signal) as close as possible to zero. More specifically, the system utilizes the fact that in addition to a zero crossing at the top of the absorption peak, the error signal also closely approximates a straight line in the vicinity of the zero crossing (see Figure 2). This vicinity is the locking range because the linearity of the error signal in this range makes it useful as a source of feedback for a proportional + integral + derivative control scheme that

  4. Gamma-Ray Peak Integration: Accuracy and Precision

    International Nuclear Information System (INIS)

    Richard M. Lindstrom

    2000-01-01

    The accuracy of singlet gamma-ray peak areas obtained by a peak analysis program is immaterial. If the same algorithm is used for sample measurement as for calibration and if the peak shapes are similar, then biases in the integration method cancel. Reproducibility is the only important issue. Even the uncertainty of the areas computed by the program is trivial because the true standard uncertainty can be experimentally assessed by repeated measurements of the same source. Reproducible peak integration was important in a recent standard reference material certification task. The primary tool used for spectrum analysis was SUM, a National Institute of Standards and Technology interactive program to sum peaks and subtract a linear background, using the same channels to integrate all 20 spectra. For comparison, this work examines other peak integration programs. Unlike some published comparisons of peak performance in which synthetic spectra were used, this experiment used spectra collected for a real (though exacting) analytical project, analyzed by conventional software used in routine ways. Because both components of the 559- to 564-keV doublet are from 76 As, they were integrated together with SUM. The other programs, however, deconvoluted the peaks. A sensitive test of the fitting algorithm is the ratio of reported peak areas. In almost all the cases, this ratio was much more variable than expected from the reported uncertainties reported by the program. Other comparisons to be reported indicate that peak integration is still an imperfect tool in the analysis of gamma-ray spectra

  5. Charge-state dependence of binary-encounter-electron cross sections and peak energies

    International Nuclear Information System (INIS)

    Hidmi, H.I.; Richard, P.; Sanders, J.M.; Schoene, H.; Giese, J.P.; Lee, D.H.; Zouros, T.J.M.; Varghese, S.L.

    1993-01-01

    The charge-state dependence of the binary-encounter-electron (BEE) double-differential cross section (DDCS) at 0 degree with respect to the beam direction resulting from collisions of 1 MeV/amu H + , C q+ , N q+ , O q+ , F q+ , Si q+ , and Cl q+ , and 0.5 MeV/amu Cu q+ with H 2 is reported. The data show an enhancement in the BEE DDCS as the charge state of the projectile is decreased, in agreement with the data reported by Richard et al. [J. Phys. B 23, L213 (1990)]. The DDCS enhancement ratios observed for the three-electron isoelectronic sequence C 3+ :C 6+ , N 4+ :N 7+ , O 5+ :O 8+ , and F 6+ :F 9+ are about 1.35, whereas a DDCS enhancement of 3.5 was observed for Cu 4+ . The BEE enhancement with increasing electrons on the projectile has been shown by several authors to be due to the non-Coulomb static potential of the projectile and additionally to the e-e exchange interaction. An impulse-approximation (IA) model fits the shape of the BEE DDCS and predicts a Z p 2 dependence for the bare-ion cross sections. The IA also predicts a binary peak energy that is independent of q and Z p and below the classical value of 4t, where t is the energy of electrons traveling with the projectile velocity. We observed a BEE energy shift ΔE (ΔE=4t-E peak , where E peak is the measured energy at the peak of the binary encounter electrons) that is approximately independent of q for the low-Z p ions, whereas the measured ΔE values for Si, Cl, and Cu were found to be q dependent

  6. Effects of dorsal and lateral decubitus on peak expiratory flow in healthy subjects

    Directory of Open Access Journals (Sweden)

    Heloisa H. Gianinis

    2013-10-01

    Full Text Available BACKGROUND: One of the measures of the pulmonary function is the peak expiratory flow (PEF that can be defined as the major flow obtained in an expiratory pressure after a complete inspiration to the level of the total lung capacity. This measure depends on the effort and strength of expiratory muscles, the airway diameter and the lung volume. OBJECTIVE: To compare the results of the peak expiratory flow in healthy male and female obtained in a seated position and dorsal decubitus (DD, right lateral decubitus (RLD and left lateral decubitus (LLD. METHOD: Thirty young subjects with mean age 22.7 years, healthy and non-smokers were included at the study, 15 of male sex. They did spirometry and IPAQ questionnaire to check the normal pulmonary function and physical activity level. The measures of PEF were performed in four positions, being performed 3 measures in which position, in a random order. Statistical analysis was performed according to Student's t test, with significance level set at 5%. RESULTS: There was a difference between the values obtained in sitting position(481±117.1 L/min with DD(453.2±116.3 L/min and RLD (454±112.9 L/min (p<0.05, however, did not find a significant difference between the sitting position and LLD (469±83 L/min. CONCLUSIONS: Body position affects the values of PEF, with decreasing values in DD and RLD. The LLD can be an alternative to optimize the expiratory flow in situations of constraint to the sitting position.

  7. Single peak parameters technique for simultaneous measurements: Spectrophotometric sequential injection determination of Fe(II) and Fe(III).

    Science.gov (United States)

    Kozak, J; Paluch, J; Węgrzecka, A; Kozak, M; Wieczorek, M; Kochana, J; Kościelniak, P

    2016-02-01

    Spectrophotometric sequential injection system (SI) is proposed to automate the method of simultaneous determination of Fe(II) and Fe(III) on the basis of parameters of a single peak. In the developed SI system, sample and mixture of reagents (1,10-phenanthroline and sulfosalicylic acid) are introduced into a vessel, where in an acid environment (pH≅3) appropriate compounds of Fe(II) and Fe(III) with 1,10-phenanthroline and sulfosalicylic acid are formed, respectively. Then, in turn, air, sample, EDTA and sample again, are introduced into a holding coil. After the flow reversal, a segment of air is removed from the system by an additional valve and as EDTA replaces sulfosalicylic acid forming a more stable colorless compound with Fe(III), a complex signal is registered. Measurements are performed at wavelength 530 nm. The absorbance measured at minimum of the negative peak and the area or the absorbance measured at maximum of the signal can be used as measures corresponding to Fe(II) and Fe(III) concentrations, respectively. The time of the peak registration is about 2 min. Two-component calibration has been applied to analysis. Fe(II) and Fe(III) can be determined within the concentration ranges of 0.04-4.00 and 0.1-5.00 mg L(-1), with precision less than 2.8% and 1.7% (RSD), respectively and accuracy better than 7% (RE). The detection limit is 0.04 and 0.09 mg L(-1) for Fe(II) and Fe(III), respectively. The method was applied to analysis of artesian water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Evaluation of different time domain peak models using extreme learning machine-based peak detection for EEG signal.

    Science.gov (United States)

    Adam, Asrul; Ibrahim, Zuwairie; Mokhtar, Norrima; Shapiai, Mohd Ibrahim; Cumming, Paul; Mubin, Marizan

    2016-01-01

    Various peak models have been introduced to detect and analyze peaks in the time domain analysis of electroencephalogram (EEG) signals. In general, peak model in the time domain analysis consists of a set of signal parameters, such as amplitude, width, and slope. Models including those proposed by Dumpala, Acir, Liu, and Dingle are routinely used to detect peaks in EEG signals acquired in clinical studies of epilepsy or eye blink. The optimal peak model is the most reliable peak detection performance in a particular application. A fair measure of performance of different models requires a common and unbiased platform. In this study, we evaluate the performance of the four different peak models using the extreme learning machine (ELM)-based peak detection algorithm. We found that the Dingle model gave the best performance, with 72 % accuracy in the analysis of real EEG data. Statistical analysis conferred that the Dingle model afforded significantly better mean testing accuracy than did the Acir and Liu models, which were in the range 37-52 %. Meanwhile, the Dingle model has no significant difference compared to Dumpala model.

  9. Impact of the Definition of Peak Standardized Uptake Value on Quantification of Treatment Response

    Science.gov (United States)

    Vanderhoek, Matt; Perlman, Scott B.; Jeraj, Robert

    2012-01-01

    PET-based treatment response assessment typically measures the change in maximum standardized uptake value (SUVmax), which is adversely affected by noise. Peak SUV (SUVpeak) has been recommended as a more robust alternative, but its associated region of interest (ROIpeak) is not uniquely defined. We investigated the impact of different ROIpeak definitions on quantification of SUVpeak and tumor response. Methods Seventeen patients with solid malignancies were treated with a multitargeted receptor tyrosine kinase inhibitor resulting in a variety of responses. Using the cellular proliferation marker 3′-deoxy-3′-18F-fluorothymidine (18F-FLT), whole-body PET/CT scans were acquired at baseline and during treatment. 18F-FLT–avid lesions (~2/patient) were segmented on PET images, and tumor response was assessed via the relative change in SUVpeak. For each tumor, 24 different SUVpeaks were determined by changing ROIpeak shape (circles vs. spheres), size (7.5–20 mm), and location (centered on SUVmax vs. placed in highest-uptake region), encompassing different definitions from the literature. Within each tumor, variations in the 24 SUVpeaks and tumor responses were measured using coefficient of variation (CV), standardized deviation (SD), and range. For each ROIpeak definition, a population average SUVpeak and tumor response were determined over all tumors. Results A substantial variation in both SUVpeak and tumor response resulted from changing the ROIpeak definition. The variable ROIpeak definition led to an intratumor SUVpeak variation ranging from 49% above to 46% below the mean (CV, 17%) and an intratumor SUVpeak response variation ranging from 49% above to 35% below the mean (SD, 9%). The variable ROIpeak definition led to a population average SUVpeak variation ranging from 24% above to 28% below the mean (CV, 14%) and a population average SUVpeak response variation ranging from only 3% above to 3% below the mean (SD, 2%). The size of ROIpeak caused more

  10. Individual vision and peak distribution in collective actions

    Science.gov (United States)

    Lu, Peng

    2017-06-01

    People make decisions on whether they should participate as participants or not as free riders in collective actions with heterogeneous visions. Besides of the utility heterogeneity and cost heterogeneity, this work includes and investigates the effect of vision heterogeneity by constructing a decision model, i.e. the revised peak model of participants. In this model, potential participants make decisions under the joint influence of utility, cost, and vision heterogeneities. The outcomes of simulations indicate that vision heterogeneity reduces the values of peaks, and the relative variance of peaks is stable. Under normal distributions of vision heterogeneity and other factors, the peaks of participants are normally distributed as well. Therefore, it is necessary to predict distribution traits of peaks based on distribution traits of related factors such as vision heterogeneity and so on. We predict the distribution of peaks with parameters of both mean and standard deviation, which provides the confident intervals and robust predictions of peaks. Besides, we validate the peak model of via the Yuyuan Incident, a real case in China (2014), and the model works well in explaining the dynamics and predicting the peak of real case.

  11. Modeling the probability distribution of peak discharge for infiltrating hillslopes

    Science.gov (United States)

    Baiamonte, Giorgio; Singh, Vijay P.

    2017-07-01

    Hillslope response plays a fundamental role in the prediction of peak discharge at the basin outlet. The peak discharge for the critical duration of rainfall and its probability distribution are needed for designing urban infrastructure facilities. This study derives the probability distribution, denoted as GABS model, by coupling three models: (1) the Green-Ampt model for computing infiltration, (2) the kinematic wave model for computing discharge hydrograph from the hillslope, and (3) the intensity-duration-frequency (IDF) model for computing design rainfall intensity. The Hortonian mechanism for runoff generation is employed for computing the surface runoff hydrograph. Since the antecedent soil moisture condition (ASMC) significantly affects the rate of infiltration, its effect on the probability distribution of peak discharge is investigated. Application to a watershed in Sicily, Italy, shows that with the increase of probability, the expected effect of ASMC to increase the maximum discharge diminishes. Only for low values of probability, the critical duration of rainfall is influenced by ASMC, whereas its effect on the peak discharge seems to be less for any probability. For a set of parameters, the derived probability distribution of peak discharge seems to be fitted by the gamma distribution well. Finally, an application to a small watershed, with the aim to test the possibility to arrange in advance the rational runoff coefficient tables to be used for the rational method, and a comparison between peak discharges obtained by the GABS model with those measured in an experimental flume for a loamy-sand soil were carried out.

  12. Fair Value in the light of IFRS 13 «Fair Value Measurement»

    OpenAIRE

    V.V. Svitselska

    2015-01-01

    The main provisions of IFRS 13 «Fair Value Measurement» have been researched as well as its critical analysis has been conducted. Comparison of the previous and the new definition of the concept «fair value» has been done on the basis of what the shortcomings of the previous definition have been highlighted, the characteristic features and advantages of new definition from IFRS 13 «Fair Value Measurement» have been outlined. It has been proved that new interpretation of the concept of «fair v...

  13. Evaluation of the Effects of Nationwide Conservation Voltage Reduction on Peak-Load Shaving Using SOMAS Data

    Directory of Open Access Journals (Sweden)

    Soon-Ryul Nam

    2013-12-01

    Full Text Available In this paper we propose a new method to evaluate the effects of nationwide conservation voltage reduction (CVR on peak-load shaving, using substation operating results management system (SOMAS data. Its evaluation is based on a national CVR factor, which is defined as the weighted average of CVR factors associated with all transformer banks and weighting coefficients are determined by the reconstructed loads corresponding to each transformer bank. To make use of the data resulting from nationwide CVR without installing additional measuring devices, we adopt a linearized static-load model with a linearizing parameter. SOMAS data are used to evaluate the effects of nationwide CVR on peak-load shaving in the Korean power system. Evaluation results show that the national CVR factor of the Korean power system has small values in the summer season and large values in the winter season. This means that the effect of nationwide CVR on peak-load shaving in the Korean power system presents stronger benefits during winter months.

  14. Sharp Absorption Peaks in THz Spectra Valuable for Crystal Quality Evaluation of Middle Molecular Weight Pharmaceuticals

    Science.gov (United States)

    Sasaki, Tetsuo; Sakamoto, Tomoaki; Otsuka, Makoto

    2018-05-01

    Middle molecular weight (MMW) pharmaceuticals (MW 400 4000) are attracting attention for their possible use in new medications. Sharp absorption peaks were observed in MMW pharmaceuticals at low temperatures by measuring with a high-resolution terahertz (THz) spectrometer. As examples, high-resolution THz spectra for amoxicillin trihydrate, atorvastatin calcium trihydrate, probucol, and α,β,γ,δ-tetrakis(1-methylpyridinium-4-yl)porphyrin p-toluenesulfonate (TMPyP) were obtained at 10 K. Typically observed as peaks with full width at half-height (FWHM) values as low as 5.639 GHz at 0.96492 THz in amoxicillin trihydrate and 8.857 GHz at 1.07974 THz for probucol, many sharp peaks of MMW pharmaceuticals could be observed. Such narrow absorption peaks enable evaluation of the crystal quality of MMW pharmaceuticals and afford sensitive detection of impurities.

  15. U-value measurements on ISO round Robin window

    DEFF Research Database (Denmark)

    Duer, Karsten

    1997-01-01

    9 laboratories in 6 european and 2 north american countries have participated in a round robin U-value test of a standard facade window. The objective of the round robin test was to verify that the ISO/CEN proposals for U-value measurement standard is robust.......9 laboratories in 6 european and 2 north american countries have participated in a round robin U-value test of a standard facade window. The objective of the round robin test was to verify that the ISO/CEN proposals for U-value measurement standard is robust....

  16. Preliminary measurements of k{sub 0} values for W-186

    Energy Technology Data Exchange (ETDEWEB)

    Barros, Lívia F.; Dias, Mauro S.; Koskinas, Marina F.; Yamazaki, Ione M.; Semmler, Renato, E-mail: lfbarros@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNE-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    There are various methods of neutron activation analysis, one of these is the k{sub 0} Method for quantitative reactor Neutron Activation Analysis (NAA). The k{sub 0}-NAA procedure is nowadays widely used in numerous laboratories performing NAA all over the world. Among these reactions, {sup 186}W(n, γ){sup 187}W can be considered important because it can be used for a W concentration measurements. The irradiations were performed at position 24A, near the core of the IEA-R1 4.5 MW swimming-pool nuclear research reactor of the Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP - Nuclear and Energy Research Institute), in Sao Paulo, Brazil. Two irradiations were carried out in sequence, using two sets of samples: the first with a cadmium cover around the samples and the second without, in a total of three data sets with and without Cd cover performed in 2014 and 2015. The activity measurements were carried out in an HPGe gamma-ray spectrometer. Standard sources of {sup 152}Eu, {sup 133}Ba, {sup 60}Co and {sup 137}Cs supplied by the IAEA were used in order to obtain the HPGe gamma-ray peak efficiency as a function of the energy. The covariance matrix methodology was applied to all uncertainties involved. The preliminary values of k{sub 0} for {sup 186}W(n, γ){sup 187}W reaction for the gamma transition energy of 479.53 keV was 3.17 x 10{sup -2}(5), for 618.77 keV was 9.08 x 10{sup -3}(15) and for 685.77 keV was 3.88x10{sup -2}(6). These preliminary values for k{sub 0} have been compared with the literature. (author)

  17. Measurement of small dispersion values in optical components

    DEFF Research Database (Denmark)

    Peucheret, Christophe; Liu, Fenghai; Pedersen, Rune Johan Skullerud

    1999-01-01

    It is reported that small dispersion values in optical components can be measured using the RF modulation method originally restricted to large dispersions. Using a constant dispersion offset, arbitrarily small dispersion values can be measured with a resolution as good as 1.2 ps/nm....

  18. The geomorphic structure of the runoff peak

    Directory of Open Access Journals (Sweden)

    R. Rigon

    2011-06-01

    Full Text Available This paper develops a theoretical framework to investigate the core dependence of peak flows on the geomorphic properties of river basins. Based on the theory of transport by travel times, and simple hydrodynamic characterization of floods, this new framework invokes the linearity and invariance of the hydrologic response to provide analytical and semi-analytical expressions for peak flow, time to peak, and area contributing to the peak runoff. These results are obtained for the case of constant-intensity hyetograph using the Intensity-Duration-Frequency (IDF curves to estimate extreme flow values as a function of the rainfall return period. Results show that, with constant-intensity hyetographs, the time-to-peak is greater than rainfall duration and usually shorter than the basin concentration time. Moreover, the critical storm duration is shown to be independent of rainfall return period as well as the area contributing to the flow peak. The same results are found when the effects of hydrodynamic dispersion are accounted for. Further, it is shown that, when the effects of hydrodynamic dispersion are negligible, the basin area contributing to the peak discharge does not depend on the channel velocity, but is a geomorphic propriety of the basin. As an example this framework is applied to three watersheds. In particular, the runoff peak, the critical rainfall durations and the time to peak are calculated for all links within a network to assess how they increase with basin area.

  19. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters

    International Nuclear Information System (INIS)

    Flores M, E.

    2007-01-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  20. Peak-locking centroid bias in Shack-Hartmann wavefront sensing

    Science.gov (United States)

    Anugu, Narsireddy; Garcia, Paulo J. V.; Correia, Carlos M.

    2018-05-01

    Shack-Hartmann wavefront sensing relies on accurate spot centre measurement. Several algorithms were developed with this aim, mostly focused on precision, i.e. minimizing random errors. In the solar and extended scene community, the importance of the accuracy (bias error due to peak-locking, quantization, or sampling) of the centroid determination was identified and solutions proposed. But these solutions only allow partial bias corrections. To date, no systematic study of the bias error was conducted. This article bridges the gap by quantifying the bias error for different correlation peak-finding algorithms and types of sub-aperture images and by proposing a practical solution to minimize its effects. Four classes of sub-aperture images (point source, elongated laser guide star, crowded field, and solar extended scene) together with five types of peak-finding algorithms (1D parabola, the centre of gravity, Gaussian, 2D quadratic polynomial, and pyramid) are considered, in a variety of signal-to-noise conditions. The best performing peak-finding algorithm depends on the sub-aperture image type, but none is satisfactory to both bias and random errors. A practical solution is proposed that relies on the antisymmetric response of the bias to the sub-pixel position of the true centre. The solution decreases the bias by a factor of ˜7 to values of ≲ 0.02 pix. The computational cost is typically twice of current cross-correlation algorithms.

  1. Spectral Doppler Waveforms for Diagnosis of Appendicitis: Potential Utility of Point Peak Systolic Velocity and Resistive Index Values.

    Science.gov (United States)

    Shin, Lewis K; Jeffrey, R Brooke; Berry, Gerald J; Olcott, Eric W

    2017-12-01

    Purpose To test the hypothesis that appendiceal spectral Doppler waveforms can distinguish patients with and patients without appendicitis. Materials and Methods In this retrospective study, Doppler waveforms were obtained from intramural appendiceal arteries identified with color Doppler imaging in 60% (93 of 155) of consecutive patients whose appendices were visualized at graded compression ultrasonography (US) performed for suspected appendicitis (53 male and 40 female; age, 1-56 years; mean, 14.5 years) over the 5-month period from November 2015 through March 2016. Point, non-angle-corrected peak systolic velocity (PSV) and resistive index (RI) values were compared between patients with and patients without appendicitis by utilizing histopathologically proven appendicitis and 6-week clinical follow-up as diagnostic reference standards. Data were assessed by using the Student t test, exact binomial distribution, two-sample test of proportions, and receiver operating characteristic analysis. Results Among the 93 patients, 36 (38.7%) had proven appendicitis (mean PSV, 19.7 cm/sec; mean RI, 0.69) and 57 patients (61.2%) did not (mean PSV, 7.1 cm/sec, P appendicitis was 0.97 (95% confidence interval [CI]: 0.95, 1.00) for PSV and 0.86 (95% CI: 0.78, 0.95; P = .011) for RI. Chosen discriminatory criteria of PSV greater than 10 cm/sec and RI greater than 0.65 yielded specificity for appendicitis of 94.7% and 96.5% with sensitivity of 88.9% and 63.9% (P = .013) and negative predictive value of 93.1% and 80.9% (P = .045), respectively. Original clinical graded compression US interpretations based on established US findings demonstrated specificity of 96.2% and sensitivity of 100.0%. Considering the subset of 20 patients whose maximum outer diameter measured 6-8 mm, the discriminatory criteria of PSV greater than 10 cm/sec and RI greater than 0.65 yielded specificity for appendicitis of 88.9% each, with sensitivity of 100.0% and 63.6% and negative predictive value of 100

  2. Measure-valued differentiation for finite products of measures : theory and applications

    NARCIS (Netherlands)

    Leahu, H.

    2008-01-01

    In this dissertation we perform a comprehensive analysis of measure-valued differentiation, in which weak differentiation of parameter-dependent probability measures plays a central role. We develop a theory of weak differentiation of measures and show that classical concepts such as differential

  3. Relationship Between Bake Hardening, Snoek-Köster and Dislocation-Enhanced Snoek Peaks in Coarse Grained Low Carbon Steel

    Directory of Open Access Journals (Sweden)

    Li Weijuan

    2016-09-01

    Full Text Available In the present work, specimens prepared from coarse grained low carbon steel with different prestrains were baked and then, their bake hardening (BH property and internal friction were determined. TEM was used to characterize the dislocation structure in BH treated samples. The measurements of internal friction in prestrained samples and baked samples were carried out using a multifunctional internal friction apparatus. The results indicate that, in coarse grained low carbon steel, the bake hardening properties (BH values were negative, which were increased by increasing the prestrain from 2 to 5%, and then were decreased by increasing the prestrain from 5 to 10%. In the specimen with prestrain 5%, the BH value reached the maximum value and the height of Snoek-Köster peak was observed to be the maximum alike. With increasing the prestrain, both of the BH value and Snoek-Köster peak heights are similarly varied. It is concluded that Snoek-Köster and dislocation-enhanced Snoek peaks, caused by the interactions between interstitial solute carbon atoms and dislocations, can be used in further development of the bake hardening steels.

  4. Weak-value measurements can outperform conventional measurements

    International Nuclear Information System (INIS)

    Magaña-Loaiza, Omar S; Boyd, Robert W; Harris, Jérémie; Lundeen, Jeff S

    2017-01-01

    In this paper we provide a simple, straightforward example of a specific situation in which weak-value amplification (WVA) clearly outperforms conventional measurement in determining the angular orientation of an optical component. We also offer a perspective reconciling the views of some theorists, who claim WVA to be inherently sub-optimal for parameter estimation, with the perspective of the many experimentalists and theorists who have used the procedure to successfully access otherwise elusive phenomena. (invited comment)

  5. Peak oxygen uptake in Paralympic sitting sports: A systematic literature review, meta- and pooled-data analysis.

    Science.gov (United States)

    Baumgart, Julia Kathrin; Brurok, Berit; Sandbakk, Øyvind

    2018-01-01

    Peak oxygen uptake (VO2peak) in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested. To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak. Systematic literature review and meta-analysis. PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean. Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included. Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak. Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1∙min-1 in wheelchair rugby. Large within-sports variation was found in sports with few

  6. Peak oxygen uptake in Paralympic sitting sports: A systematic literature review, meta- and pooled-data analysis.

    Directory of Open Access Journals (Sweden)

    Julia Kathrin Baumgart

    Full Text Available Peak oxygen uptake (VO2peak in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested.To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak.Systematic literature review and meta-analysis.PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean.Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included.Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak.Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1∙min-1 in wheelchair rugby. Large within-sports variation was found in

  7. Neutron-induced peaks in Ge detectors from evaporation neutrons

    International Nuclear Information System (INIS)

    Gete, E.; Measday, D.F.; Moftah, B.A.; Saliba, M.A.; Stocki, T.J.

    1997-01-01

    We have studied the peak shapes at 596 and 691 keV resulting from fast neutron interactions inside germanium detectors. We have used neutrons from a 252 Cf source, as well as from the 28 Si(μ - , nν), and 209 Bi(π - , xn) reactions to compare the peaks and to check for a dependence of peak shape on the incoming neutron energy. In our investigation, no difference between these three measurements has been observed. In a comparison of these peak shapes with other studies, we found similar results to ours except for those measurements using monoenergetic neutrons in which a significant variation with neutron energy has been observed. (orig.)

  8. Lattice-Valued Possibilistic Entropy Measure

    Czech Academy of Sciences Publication Activity Database

    Kramosil, Ivan

    2008-01-01

    Roč. 16, č. 6 (2008), s. 829-846 ISSN 0218-4885 R&D Projects: GA AV ČR IAA100300503 Institutional research plan: CEZ:AV0Z10300504 Keywords : complete lattice * lattice-valued possibilistic distribution * entropy measure * product of possibilistic distribution Subject RIV: BA - General Mathematics Impact factor: 1.000, year: 2008

  9. Focused ultrasound transducer spatial peak intensity estimation: a comparison of methods

    Science.gov (United States)

    Civale, John; Rivens, Ian; Shaw, Adam; ter Haar, Gail

    2018-03-01

    Characterisation of the spatial peak intensity at the focus of high intensity focused ultrasound transducers is difficult because of the risk of damage to hydrophone sensors at the high focal pressures generated. Hill et al (1994 Ultrasound Med. Biol. 20 259-69) provided a simple equation for estimating spatial-peak intensity for solid spherical bowl transducers using measured acoustic power and focal beamwidth. This paper demonstrates theoretically and experimentally that this expression is only strictly valid for spherical bowl transducers without a central (imaging) aperture. A hole in the centre of the transducer results in over-estimation of the peak intensity. Improved strategies for determining focal peak intensity from a measurement of total acoustic power are proposed. Four methods are compared: (i) a solid spherical bowl approximation (after Hill et al 1994 Ultrasound Med. Biol. 20 259-69), (ii) a numerical method derived from theory, (iii) a method using measured sidelobe to focal peak pressure ratio, and (iv) a method for measuring the focal power fraction (FPF) experimentally. Spatial-peak intensities were estimated for 8 transducers at three drive powers levels: low (approximately 1 W), moderate (~10 W) and high (20-70 W). The calculated intensities were compared with those derived from focal peak pressure measurements made using a calibrated hydrophone. The FPF measurement method was found to provide focal peak intensity estimates that agreed most closely (within 15%) with the hydrophone measurements, followed by the pressure ratio method (within 20%). The numerical method was found to consistently over-estimate focal peak intensity (+40% on average), however, for transducers with a central hole it was more accurate than using the solid bowl assumption (+70% over-estimation). In conclusion, the ability to make use of an automated beam plotting system, and a hydrophone with good spatial resolution, greatly facilitates characterisation of the FPF, and

  10. U-value measurements on a roof window

    DEFF Research Database (Denmark)

    Duer, Karsten

    1998-01-01

    This report describes the results of the U-value measurements performed on a roof window. The work is as a part of the development of an ISO/CEN standard measuring procedure for roof windows.The measurements have been performed using the procedures given in ISO 12567 draft version 1998...

  11. On the audit of fair value measurements

    Directory of Open Access Journals (Sweden)

    Jatinder P. Singh

    2015-04-01

    Full Text Available In this article, the hypotheses „whether the auditor’s functional domain, his approach, methodology and responsibilities are undergoing a metamorphosis with the adoption of Fair Value Accounting (hereinafter the „FVA” and whether his/her role is moving away from the mechanized attester of tangible evidence to the one exercising a substantively judgmental function in a holistic assessment of the values ascribed to be fair by the entity’s management” are tested. These hypotheses are tested on the basis of an analysis of the statutory provisions, the pronouncements of accounting and other regulatory bodies and accounting norms and theories. After setting forth the research objectives and the hypotheses, the necessity of the FVA is reviewed and the underlying philosophy is analyzed. Impediments in performing audits of fair-value-based measurements are then identified and the US auditing standards and their international counterparts are touched upon. Finally, some safeguards and precautions for the auditor in an audit of fair-value measurements are presented.

  12. Monitoring device for local power peaking coefficient

    International Nuclear Information System (INIS)

    Mitsuhashi, Ishi

    1987-01-01

    Purpose: To monitor the local power peaking coefficients obtained by the method not depending on the combination of fuel types. Method: A plurality of representative values for the local power distribution determined by the nuclear constant calculation for one fuel assembly are memorized regarding each of the burn-up degree and the void coefficient on every positions and fuel types in fuel rod assemblies. While on the other hand, the representative values for the local power distribution as described above are compensated by a compensation coefficient considering the effect of adjacent segments and a control rod compensation coefficient considering the effect due to the control rod insertion relative to the just-mentioned compensation coefficient. Then, the maximum value among them is selected to determine the local power peaking coefficient at each of the times and each of the segments, which is monitored. According to this system, the calculation and the working required for the fitting work depending on the combination of fuel types are no more required at all to facilitate the maintenance as well. (Horiuchi, T.)

  13. VALUE AT RISK - CORPORATE RISK MEASUREMENT

    Directory of Open Access Journals (Sweden)

    Anis Cecilia-Nicoleta

    2011-12-01

    Full Text Available The notion of 'risk' is used in a number of sciences. The Faculty of Law studies the risk depending on its legality. The Accident Theory applies this term to describe the damage and the disasters. One can find studies on the risks in the works of psychology, philosophy, medicine and within each of these areas the study of the risk is based on the given science subject and, of course, on their methods and approaches. Such a variety of risk study is explained by the diversity of this phenomenon. Under the market economy conditions, the risk is an essential component of any economic agent management policy, of the approach developed by this one, a strategy that depends almost entirely on individual ability and capacity to anticipate his evolution and to exploit his opportunities, assuming a so-called 'risk of business failure.' There are several ways to measure the risks in projects, one of the most used methods to measure this being the Value at Risk(VaR. Value at Risk (VaR was made famous by JP Morgan in the mid 1990s, by introducing the RiskMetrics approach, and hence, by far, has been sanctioned by several Governing Bodies throughout the world bank. In short, it measures the value of risk capital stocks in a given period at a certain probability of loss. This measurement can be modified for risk applications through, for example, the potential loss values affirmation in a certain amount of time during the economic life of the project- clearly, a project with a lower VaR is better. It should be noted that it is not always possible or advisable for a company to limit itself to the remote analysis of each risk because the risks and their effects are interdependent and constitute a system .In addition, there are risks which, in combination with other risks, tend to produce effects which they would not have caused by themselves and risks that tend to offset and even cancel each other out.

  14. PEAK TRACKING WITH A NEURAL NETWORK FOR SPECTRAL RECOGNITION

    NARCIS (Netherlands)

    COENEGRACHT, PMJ; METTING, HJ; VANLOO, EM; SNOEIJER, GJ; DOORNBOS, DA

    1993-01-01

    A peak tracking method based on a simulated feed-forward neural network with back-propagation is presented. The network uses the normalized UV spectra and peak areas measured in one chromatogram for peak recognition. It suffices to train the network with only one set of spectra recorded in one

  15. Technology for computer-stabilized peak of NaI(Tl) gamma spectrum

    International Nuclear Information System (INIS)

    Chen Jianzhen; Guo Lanying; Ling Qiu; Qu Guopu; Zhao Lihong; Hu Chuangye

    2005-01-01

    An improved technology for spectrum stabilization of NaI(Tl) gamma spectrum was introduced. This technology is based on the system using a reference peak, which is equivalent gamma peak of 241 Am source. The computer seeks peak's position deviation and computes adjust value of programmable amplifier and controls programmable amplifier to stabilize spectrum by digital PID. This is a technology of spectrum stabilizing with 'hardware + reference-peak + software' and has high stability and fast speed of spectrum stabilizing. (author)

  16. Complex Fuzzy Set-Valued Complex Fuzzy Measures and Their Properties

    Science.gov (United States)

    Ma, Shengquan; Li, Shenggang

    2014-01-01

    Let F*(K) be the set of all fuzzy complex numbers. In this paper some classical and measure-theoretical notions are extended to the case of complex fuzzy sets. They are fuzzy complex number-valued distance on F*(K), fuzzy complex number-valued measure on F*(K), and some related notions, such as null-additivity, pseudo-null-additivity, null-subtraction, pseudo-null-subtraction, autocontionuous from above, autocontionuous from below, and autocontinuity of the defined fuzzy complex number-valued measures. Properties of fuzzy complex number-valued measures are studied in detail. PMID:25093202

  17. Peak oxygen uptake in Paralympic sitting sports: A systematic literature review, meta- and pooled-data analysis

    Science.gov (United States)

    Brurok, Berit; Sandbakk, Øyvind

    2018-01-01

    Background Peak oxygen uptake (VO2peak) in Paralympic sitting sports athletes represents their maximal ability to deliver energy aerobically in an upper-body mode, with values being influenced by sex, disability-related physiological limitations, sport-specific demands, training status and how they are tested. Objectives To identify VO2peak values in Paralympic sitting sports, examine between-sports differences and within-sports variations in VO2peak and determine the influence of sex, age, body-mass, disability and test-mode on VO2peak. Design Systematic literature review and meta-analysis. Data sources PubMed, CINAHL, SPORTDiscusTM and EMBASE were systematically searched in October 2016 using relevant medical subject headings, keywords and a Boolean. Eligibility criteria Studies that assessed VO2peak values in sitting sports athletes with a disability in a laboratory setting were included. Data synthesis Data was extracted and pooled in the different sports disciplines, weighted by the Dersimonian and Laird random effects approach. Quality of the included studies was assessed with a modified version of the Downs and Black checklist by two independent reviewers. Meta-regression and pooled-data multiple regression analyses were performed to assess the influence of sex, age, body-mass, disability, test mode and study quality on VO2peak. Results Of 6542 retrieved articles, 57 studies reporting VO2peak values in 14 different sitting sports were included in this review. VO2peak values from 771 athletes were used in the data analysis, of which 30% participated in wheelchair basketball, 27% in wheelchair racing, 15% in wheelchair rugby and the remaining 28% in the 11 other disciplines. Fifty-six percent of the athletes had a spinal cord injury and 87% were men. Sports-discipline-averaged VO2peak values ranged from 2.9 L∙min-1 and 45.6 mL∙kg-1∙min-1 in Nordic sit skiing to 1.4 L∙min-1 and 17.3 mL∙kg-1∙min-1 in shooting and 1.3 L∙min-1 and 18.9 mL∙kg-1

  18. Degree of conversion of resin-based materials cured with dual-peak or single-peak LED light-curing units.

    Science.gov (United States)

    Lucey, Siobhan M; Santini, Ario; Roebuck, Elizabeth M

    2015-03-01

    There is a lack of data on polymerization of resin-based materials (RBMs) used in paediatric dentistry, using dual-peak light-emitting diode (LED) light-curing units (LCUs). To evaluate the degree of conversion (DC) of RBMs cured with dual-peak or single-peak LED LCUs. Samples of Vit-l-escence (Ultradent) and Herculite XRV Ultra (Kerr) and fissure sealants Delton Clear and Delton Opaque (Dentsply) were prepared (n = 3 per group) and cured with either one of two dual-peak LCUs (bluephase(®) G2; Ivoclar Vivadent or Valo; Ultradent) or a single-peak (bluephase(®) ; Ivoclar Vivadent). High-performance liquid chromatography and nuclear magnetic resonance spectroscopy were used to confirm the presence or absence of initiators other than camphorquinone. The DC was determined using micro-Raman spectroscopy. Data were analysed using general linear model anova; α = 0.05. With Herculite XRV Ultra, the single-peak LCU gave higher DC values than either of the two dual-peak LCUs (P < 0.05). Both fissure sealants showed higher DC compared with the two RBMs (P < 0.05); the DC at the bottom of the clear sealant was greater than the opaque sealant, (P < 0.05). 2,4,6-trimethylbenzoyldiphenylphosphine oxide (Lucirin(®) TPO) was found only in Vit-l-escence. Dual-peak LED LCUs may not be best suited for curing non-Lucirin(®) TPO-containing materials. A clear sealant showed a better cure throughout the material and may be more appropriate than opaque versions in deep fissures. © 2014 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Measuring the strategic value of information technology investments

    International Nuclear Information System (INIS)

    Conrad, K.W.

    1994-08-01

    Value is often perceived differently by the proponents of new information technologies and those who allocate resources and define priorities. Such differences often become a roadblock to meeting true business needs. Project justifications regularly rely on calculated cost savings, which rarely measure the full benefit of new technologies. In fact, if cost savings provide a complete picture, then the organization is probably just automating routine clerical operations and has abandoned efforts that would provide significant strategic value. Strategic value is not limited to financial calculations, but includes quality, time and risk criteria. This paper describes approaches for measuring strategic value that can provide organizations with proven techniques to improve performance, reengineer processes, benchmark performance against other suppliers, identify outsourcing opportunities, or defend themselves from pressures to outsource. Many organizations respond to tightening budgets by cutting overhead. These measurement approaches can demonstrate how overhead is critical to organizational effectiveness and how cost savings can be found, instead, by measurably improving performance throughout the organization. Finally, the paper describes efforts underway within the Department of Energy and at the Hanford Site to implement the approaches described in this paper

  20. Measuring the strategic value of information technology investments

    Energy Technology Data Exchange (ETDEWEB)

    Conrad, K.W. [Boeing Computer Services Co., Richland, WA (United States)

    1994-08-01

    Value is often perceived differently by the proponents of new information technologies and those who allocate resources and define priorities. Such differences often become a roadblock to meeting true business needs. Project justifications regularly rely on calculated cost savings, which rarely measure the full benefit of new technologies. In fact, if cost savings provide a complete picture, then the organization is probably just automating routine clerical operations and has abandoned efforts that would provide significant strategic value. Strategic value is not limited to financial calculations, but includes quality, time and risk criteria. This paper describes approaches for measuring strategic value that can provide organizations with proven techniques to improve performance, reengineer processes, benchmark performance against other suppliers, identify outsourcing opportunities, or defend themselves from pressures to outsource. Many organizations respond to tightening budgets by cutting overhead. These measurement approaches can demonstrate how overhead is critical to organizational effectiveness and how cost savings can be found, instead, by measurably improving performance throughout the organization. Finally, the paper describes efforts underway within the Department of Energy and at the Hanford Site to implement the approaches described in this paper.

  1. Historical Costs versus Fair Value Measurement in Financial Accounting

    OpenAIRE

    Dvořáková, Dana

    2009-01-01

    There are two important points in which in which we need assets and liabilities measured in financial accounting: on initial recognition and at a balance sheet day. Many International Financial Reporting Standards (IFRS) used the fair value measurement concept. But most of these standards use the fair value measurement method only at a balance sheet day. On initial recognition assets and liabilities are measured usually at costs. The IASB presented the discussion paper “Measurement Bases for ...

  2. Peak expiratory flow as a predictor for the effectiveness of sport for patients with COPD.

    Science.gov (United States)

    Jungblut, S; Frickmann, H; Klingler, J; Zimmermann, B; Bargon, Joachim

    2006-01-31

    This study intended to find simple parameters that were able to determine the increase in physical performance as a result of sport in a group of patients with COPD (lung sport). We regularly investigated pulse, oxygenation and peak expiratory flow in participants with COPD of a "lung sport group", who participated in a structured weekly training program under professional supervision. Ten volunteers (7 females, 3 males, median of age = 69) with COPD (grade II-III) took part in the study. - The relative changes after 3 and 6 months were compared with the values of the first month of exercise. Measurements were carried out before exercise, after stamina training and at the end of the program. - Pulse and oxygenation did not show any changes. However, there was a significant improvement of peak flow after 6 months. - These peak flow changes represent further evidence of positive effects of sport in COPD and provide a parameter which allows the patients themselves to measure and evaluate the success of their physical activity.

  3. Several peaks of total current in Trichel pulse

    International Nuclear Information System (INIS)

    Bolotov, O.; Golota, V.; Kadolin, B.; Mankovskyi, S.; Ostroushko, V.; Pashchenko, I.; Taran, G.; Zavada, L.

    2015-01-01

    The numerical simulations of negative corona at constant voltage in Trichel pulse mode are carried out in assumptions of presence and absence of photoemission from cathode. In absence of photoemission two peaks of total current or the step before the main peak were obtained for very small values of ion-electron emission coefficient. In presence of photoemission there were observed several maximums, connected with instability development of the process based on radiation of photons, photoemission, and avalanche multiplication

  4. 21 CFR 868.1860 - Peak-flow meter for spirometry.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Peak-flow meter for spirometry. 868.1860 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1860 Peak-flow meter for spirometry. (a) Identification. A peak-flow meter for spirometry is a device used to measure a patient's...

  5. Estimation of the peak factor based on watershed characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Gauthier, Jean; Nolin, Simon; Ruest, Benoit [BPR Inc., Quebec, (Canada)

    2010-07-01

    Hydraulic modeling and dam structure design require the river flood flow as a primary input. For a given flood event, the ratio of peak flow over mean daily flow defines the peak factor. The peak factor value is dependent on the watershed and location along the river. The main goal of this study consisted in finding a relationship between watershed characteristics and this peak factor. Regression analyses were carried out on 53 natural watersheds located in the southern part of the province of Quebec using data from the Centre d'expertise hydrique du Quebec (CEHQ). The watershed characteristics included in the analyses were the watershed area, the maximum flow length, the mean slope, the lake proportion and the mean elevation. The results showed that watershed area and length are the major parameters influencing the peak factor. Nine natural watersheds were also used to test the use of a multivariable model in order to determine the peak factor for ungauged watersheds.

  6. Calibration of HPGe detector for in situ measurements of 137Cs in soil by 'peak to valley' method

    International Nuclear Information System (INIS)

    Fueloep, M.

    2000-01-01

    The contamination of soil with gamma-ray emitters can be measured in two ways: soil sampling method and in situ spectrometry of the ambient gamma-ray radiation. The conventional soil sampling method has two disadvantages: samples may not be representative for a large areas and determination of the depth distribution of radionuclide requires the measurement of several samples taken from different depths. In situ measurement of a radionuclide activity in soil is more sensitive and provides more representative data than data obtained by soil sample collection and subsequent laboratory analysis. In emergency situations time to assess the contamination is critical. For rapid assessment of the deposited activity direct measurement of ambient gamma-ray radiation are used. In order to obtain accurate measurements of radionuclides in the soil, the detector should be placed on relatively even and open terrain. It is our customary practice to place the detector 1 m above the soil surface. At this height, a tripod-mounted detector can be handled easily and still provide a radius of view for gamma emitting sources out to about 10 m. The 'field of view' actually varies, being somewhat larger for higher sources. Depending upon source energy, the detector effectively sees down to a depth of 15-30 cm. Commonly used method for field gamma spectrometry is method by Beck (1). The most important disadvantages of in situ spectrometry by Beck are that the accuracy of the analysis depends on a separate knowledge of the radioactivity distribution with soil depth. This information can be obtained by calculations using data from in situ measurements and energy dependence of absorption and scattering of photons in soil and track length distribution of photons in soil (2). A method of in situ measurements of 137 Cs in soil where radionuclide distribution in soil profile is calculated by unfolding of detector responses in the full energy peak net area at 0.662 MeV and in the valley under the

  7. Value of MR phase-contrast flow measurements for functional assessment of pulmonary arterial hypertension

    International Nuclear Information System (INIS)

    Ley, Sebastian; Mereles, Derliz; Gruenig, Ekkehard; Puderbach, Michael; Schoeck, Helena; Eichinger, Monika; Ley-Zaporozhan, Julia; Fink, Christian; Kauczor, Hans-Ulrich

    2007-01-01

    Goals of our study were to compare the pulmonary hemodynamics between healthy volunteers and patients with pulmonary arterial hypertension (PAH) and correlate MR flow measurements with echocardiography. Twenty-five patients with PAH and 25 volunteers were examined at 1.5 T. Phase-contrast flow measurements were performed in the ascending aorta and pulmonary trunk, resulting in the following parameters: peak velocity (cm/s), average blood flow (l/min), time to peak velocity (ms), velocity rise gradient and pulmonary distensibility (cm 2 ). The bronchosystemic shunt was calculated. In PAH patients transthoracic echocardiography and right-heart catheterization (RHC) served as the gold standard. In comparison to volunteers, the PAH patients showed significantly reduced pulmonary velocities (P = 0.002), blood flow (P = 0.002) and pulmonary distensibility (P = 0.008). In patients, the time to peak velocity was shorter (P<0.001), and the velocity rise gradient was steeper (P = 0.002) than in volunteers. While in volunteers the peak velocity in the aorta was reached earlier, it was the reverse in patients. Patients showed a significant bronchosystemic shunt (P = 0.01). No meaningful correlation was found between MRI measurements and echocardiography or RHC. MRI is a feasible technique for the differentiation between PAH and volunteers. Further studies have to be conducted for the absolute calculation of pressure estimates. (orig.)

  8. Exponential Increase in Relative Biological Effectiveness Along Distal Edge of a Proton Bragg Peak as Measured by Deoxyribonucleic Acid Double-Strand Breaks

    Energy Technology Data Exchange (ETDEWEB)

    Cuaron, John J., E-mail: cuaronj@mskcc.org [Memorial Sloan Kettering Cancer Center, New York, New York (United States); Chang, Chang [Texas Center for Proton Therapy, Irving, Texas (United States); Lovelock, Michael; Higginson, Daniel S. [Memorial Sloan Kettering Cancer Center, New York, New York (United States); Mah, Dennis [Procure Proton Therapy Center, Somerset, New Jersey (United States); Cahlon, Oren; Powell, Simon [Memorial Sloan Kettering Cancer Center, New York, New York (United States)

    2016-05-01

    Purpose: To quantify the relative biological effectiveness (RBE) of the distal edge of the proton Bragg peak, using an in vitro assay of DNA double-strand breaks (DSBs). Methods and Materials: U2OS cells were irradiated within the plateau of a spread-out Bragg peak and at each millimeter position along the distal edge using a custom slide holder, allowing for simultaneous measurement of physical dose. A reference radiation signal was generated using photons. The DNA DSBs at 3 hours (to assess for early damage) and at 24 hours (to assess for residual damage and repair) after irradiation were measured using the γH2AX assay and quantified via flow cytometry. Results were confirmed with clonogenic survival assays. A detailed map of the RBE as a function of depth along the Bragg peak was generated using γH2AX measurements as a biological endpoint. Results: At 3 hours after irradiation, DNA DSBs were higher with protons at every point along the distal edge compared with samples irradiated with photons to similar doses. This effect was even more pronounced after 24 hours, indicating that the impact of DNA repair is less after proton irradiation relative to photons. The RBE demonstrated an exponential increase as a function of depth and was measured to be as high as 4.0 after 3 hours and as high as 6.0 after 24 hours. When the RBE-corrected dose was plotted as a function of depth, the peak effective dose was extended 2-3 mm beyond what would be expected with physical measurement. Conclusions: We generated a highly comprehensive map of the RBE of the distal edge of the Bragg peak, using a direct assay of DNA DSBs in vitro. Our data show that the RBE of the distal edge increases with depth and is significantly higher than previously reported estimates.

  9. Limitations of middle cerebral artery peak systolic velocity in the ...

    African Journals Online (AJOL)

    We present a case of a mother with severe pre-eclampsia at 32 weeks' gestation and non-immune fetal hydrops without obvious cause. Since the. MCA peak systolic velocity (PSV) was ... Limitations of middle cerebral artery peak systolic velocity .... [7] found MCA PSV of value in 9 women with chronic abruption, but in 5.

  10. Bayesian approach for peak detection in two-dimensional chromatography.

    Science.gov (United States)

    Vivó-Truyols, Gabriel

    2012-03-20

    A new method for peak detection in two-dimensional chromatography is presented. In a first step, the method starts with a conventional one-dimensional peak detection algorithm to detect modulated peaks. In a second step, a sophisticated algorithm is constructed to decide which of the individual one-dimensional peaks have been originated from the same compound and should then be arranged in a two-dimensional peak. The merging algorithm is based on Bayesian inference. The user sets prior information about certain parameters (e.g., second-dimension retention time variability, first-dimension band broadening, chromatographic noise). On the basis of these priors, the algorithm calculates the probability of myriads of peak arrangements (i.e., ways of merging one-dimensional peaks), finding which of them holds the highest value. Uncertainty in each parameter can be accounted by adapting conveniently its probability distribution function, which in turn may change the final decision of the most probable peak arrangement. It has been demonstrated that the Bayesian approach presented in this paper follows the chromatographers' intuition. The algorithm has been applied and tested with LC × LC and GC × GC data and takes around 1 min to process chromatograms with several thousands of peaks.

  11. Peak Pc Prediction in Conjunction Analysis: Conjunction Assessment Risk Analysis. Pc Behavior Prediction Models

    Science.gov (United States)

    Vallejo, J.J.; Hejduk, M.D.; Stamey, J. D.

    2015-01-01

    Satellite conjunction risk typically evaluated through the probability of collision (Pc). Considers both conjunction geometry and uncertainties in both state estimates. Conjunction events initially discovered through Joint Space Operations Center (JSpOC) screenings, usually seven days before Time of Closest Approach (TCA). However, JSpOC continues to track objects and issue conjunction updates. Changes in state estimate and reduced propagation time cause Pc to change as event develops. These changes a combination of potentially predictable development and unpredictable changes in state estimate covariance. Operationally useful datum: the peak Pc. If it can reasonably be inferred that the peak Pc value has passed, then risk assessment can be conducted against this peak value. If this value is below remediation level, then event intensity can be relaxed. Can the peak Pc location be reasonably predicted?

  12. Improved Peak Detection and Deconvolution of Native Electrospray Mass Spectra from Large Protein Complexes.

    Science.gov (United States)

    Lu, Jonathan; Trnka, Michael J; Roh, Soung-Hun; Robinson, Philip J J; Shiau, Carrie; Fujimori, Danica Galonic; Chiu, Wah; Burlingame, Alma L; Guan, Shenheng

    2015-12-01

    Native electrospray-ionization mass spectrometry (native MS) measures biomolecules under conditions that preserve most aspects of protein tertiary and quaternary structure, enabling direct characterization of large intact protein assemblies. However, native spectra derived from these assemblies are often partially obscured by low signal-to-noise as well as broad peak shapes because of residual solvation and adduction after the electrospray process. The wide peak widths together with the fact that sequential charge state series from highly charged ions are closely spaced means that native spectra containing multiple species often suffer from high degrees of peak overlap or else contain highly interleaved charge envelopes. This situation presents a challenge for peak detection, correct charge state and charge envelope assignment, and ultimately extraction of the relevant underlying mass values of the noncovalent assemblages being investigated. In this report, we describe a comprehensive algorithm developed for addressing peak detection, peak overlap, and charge state assignment in native mass spectra, called PeakSeeker. Overlapped peaks are detected by examination of the second derivative of the raw mass spectrum. Charge state distributions of the molecular species are determined by fitting linear combinations of charge envelopes to the overall experimental mass spectrum. This software is capable of deconvoluting heterogeneous, complex, and noisy native mass spectra of large protein assemblies as demonstrated by analysis of (1) synthetic mononucleosomes containing severely overlapping peaks, (2) an RNA polymerase II/α-amanitin complex with many closely interleaved ion signals, and (3) human TriC complex containing high levels of background noise. Graphical Abstract ᅟ.

  13. SU-E-T-499: Comparison of Measured Tissue Phantom Ratios (TPR) Against Calculated From Percent Depth Doses (PDD) with and Without Peak Scatter Factor (PSF) in 6MV Open Beam

    International Nuclear Information System (INIS)

    Narayanasamy, G; Cruz, W; Gutierrez, Alonso; Mavroidis, Panayiotis; Papanikolaou, N; Stathakis, S; Breton, C

    2014-01-01

    Purpose: To examine the accuracy of measured tissue phantom ratios (TPR) values with TPR calculated from percentage depth dose (PDD) with and without peak scatter fraction (PSF) correction. Methods: For 6MV open beam, TPR and PDD values were measured using PTW Semiflex (31010) ionization field and reference chambers (0.125cc volume) in a PTW MP3-M water tank. PDD curves were measured at SSD of 100cm for 7 square fields from 3cm to 30cm. The TPR values were measured up to 22cm depth for the same fields by continuous water draining method with ionization chamber static at 100cm from source. A comparison study was performed between the (a) measured TPR, (b) TPR calculated from PDD without PSF, (c) TPR calculated from PDD with PSF and (d) clinical TPR from RadCalc (ver 6.2, Sun Nuclear Corp). Results: There is a field size, depth dependence on TPR values. For 10cmx10cm, the differences in surface dose (DDs), dose at 10cm depth (DD10) <0.5%; differences in dmax (Ddmax) <2mm for the 4 methods. The corresponding values for 30cmx30cm are DDs, DD10 <0.2% and Ddmax<3mm. Even though for 3cmx3cm field, DDs and DD10 <1% and Ddmax<1mm, the calculated TPR values with and without PSF correction differed by 2% at >20cm depth. In all field sizes at depths>28cm, (d) clinical TPR values are larger than that from (b) and (c) by >3%. Conclusion: Measured TPR in method (a) differ from calculated TPR in methods (b) and (c) to within 1% for depths < 28cm in all 7 fields in open 6MV beam. The dmax values are within 3mm of each other. The largest deviation of >3% was observed in clinical TPR values in method (d) for all fields at depths < 28cm

  14. Use of sum-peak and coincidence counting methods for activity standardization of {sup 22}Na

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, E.M. de, E-mail: estela@ird.gov.br [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Iwahara, A.; Poledna, R. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Silva, M.A.L. da [Coordenacao Geral de Instalacoes Nucleares/Comissao Nacional de Energia Nuclear, R. Gal. Severiano, 90 - Botafogo, CEP 22290-901 Rio de Janeiro (Brazil); Tauhata, L. [Fundacao Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro (FAPERJ), Av. Erasmo Braga, 118-6 Degree-Sign andar, CEP 20020-000 Centro, Rio de Janeiro (Brazil); Delgado, J.U. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, R.T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68509, CEP 21945-970 Rio de Janeiro (Brazil)

    2012-09-21

    A solution containing the positron emitter {sup 22}Na has been absolutely standardized using the 4{pi}{beta}-{gamma} coincidence counting method and the sum-peak spectrometry counting method. In the 4{pi}{beta}-{gamma} coincidence method two ways for the activity concentration measurements were used: gating on the 1275 keV photopeak and on the 1786 keV sum-peak where the knowledge of the {beta}{sup +}-branching ratio is required. In the sum-peak method the measurements were carried out using three experimental arrangements: the first composed by a well type 5 in. Multiplication-Sign 5 in. NaI(Tl) scintillation crystal, the second by a 3 in. Multiplication-Sign 3 in. NaI(Tl) scintillation crystal placed on the top of the first, resulting in a 4{pi} counting geometry and the third arrangement is a high purity coaxial germanium detector. The results that are obtained by these two methods are compatible within the standard uncertainty values with a coverage factor of k=2 ({approx}95% of the confidence level). This means that the sum-peak counting with its more simple experimental setup than the complex coincidence 4{pi}{beta}-{gamma} counting system gives consistent results for the activity standardization of {sup 22}Na with smaller uncertainties. Besides, the time period involved to attain the result of the standardization was quite shorter than the coincidence measurements used in this work.

  15. A measurement by BOOMERANG of multiple peaks in the angular power spectrum of the cosmic microwave background

    Science.gov (United States)

    Netterfield, C. B.; Ade, P. A. R.; Bock, J. J.; Bond, J. R.; Borrill, J.; Boscaleri, A.; Coble, K.; Contaldi, C. R.; Crill, B. P.; Bernardis, P. de; hide

    2001-01-01

    This paper presents a measurement of the angular power spectrum of the Cosmic Microwave Background from l = 75 to l = 1025 (10' to 5 degrees) from a combined analysis of four 150 GHz channels in the BOOMERANG experiment. The spectrum contains multiple peaks and minima, as predicted by standard adiabatic-inflationary models in which the primordial plasma undergoes acoustic oscillations.

  16. On set-valued functionals: Multivariate risk measures and Aumann integrals

    Science.gov (United States)

    Ararat, Cagin

    In this dissertation, multivariate risk measures for random vectors and Aumann integrals of set-valued functions are studied. Both are set-valued functionals with values in a complete lattice of subsets of Rm. Multivariate risk measures are considered in a general d-asset financial market with trading opportunities in discrete time. Specifically, the following features of the market are incorporated in the evaluation of multivariate risk: convex transaction costs modeled by solvency regions, intermediate trading constraints modeled by convex random sets, and the requirement of liquidation into the first m ≤ d of the assets. It is assumed that the investor has a "pure" multivariate risk measure R on the space of m-dimensional random vectors which represents her risk attitude towards the assets but does not take into account the frictions of the market. Then, the investor with a d-dimensional position minimizes the set-valued functional R over all m-dimensional positions that she can reach by trading in the market subject to the frictions described above. The resulting functional Rmar on the space of d-dimensional random vectors is another multivariate risk measure, called the market-extension of R. A dual representation for R mar that decomposes the effects of R and the frictions of the market is proved. Next, multivariate risk measures are studied in a utility-based framework. It is assumed that the investor has a complete risk preference towards each individual asset, which can be represented by a von Neumann-Morgenstern utility function. Then, an incomplete preference is considered for multivariate positions which is represented by the vector of the individual utility functions. Under this structure, multivariate shortfall and divergence risk measures are defined as the optimal values of set minimization problems. The dual relationship between the two classes of multivariate risk measures is constructed via a recent Lagrange duality for set optimization. In

  17. Comparison of the two relaxation peaks in the Ti50Ni48Fe2 alloy

    International Nuclear Information System (INIS)

    Fan Genlian; Zhou Yumei; Otsuka, Kazuhiro; Ren Xiaobing; Suzuki, Tetsuro; Yin Fuxing

    2009-01-01

    The internal friction (tan δ) and storage modulus of Ti 50 Ni 48 Fe 2 alloy were studied by dynamic mechanical analysis (DMA). On cooling, a broad relaxation peak with tan δ value as high as 0.2 was detected in R-phase. On heating, another relaxation peak with tan δ value of 0.06 was found in B19' martensite. Both relaxation peaks disappeared when the alloy was dehydrogenated in a dynamic vacuum furnace. Thus, the origin of both relaxation peaks was attributed to the interaction between twin boundaries and hydrogen atoms, as recently proved in Ti-Ni-Cu alloy. The direct comparison of these two relaxation peaks in the same sample indicates that the height of relaxation peaks increases with the decreasing of twinning shear.

  18. Smart ECG Monitoring Patch with Built-in R-Peak Detection for Long-Term HRV Analysis.

    Science.gov (United States)

    Lee, W K; Yoon, H; Park, K S

    2016-07-01

    Since heart rate variability (HRV) analysis is widely used to evaluate the physiological status of the human body, devices specifically designed for such applications are needed. To this end, we developed a smart electrocardiography (ECG) patch. The smart patch measures ECG using three electrodes integrated into the patch, filters the measured signals to minimize noise, performs analog-to-digital conversion, and detects R-peaks. The measured raw ECG data and the interval between the detected R-peaks can be recorded to enable long-term HRV analysis. Experiments were performed to evaluate the performance of the built-in R-wave detection, robustness of the device under motion, and applicability to the evaluation of mental stress. The R-peak detection results obtained with the device exhibited a sensitivity of 99.29%, a positive predictive value of 100.00%, and an error of 0.71%. The device also exhibited less motional noise than conventional ECG recording, being stable up to a walking speed of 5 km/h. When applied to mental stress analysis, the device evaluated the variation in HRV parameters in the same way as a normal ECG, with very little difference. This device can help users better understand their state of health and provide physicians with more reliable data for objective diagnosis.

  19. Consistency between Self-Reported and Recorded Values for Clinical Measures

    OpenAIRE

    III, Joseph Thomas; Paulet, Mindy; Rajpura, Jigar R.

    2016-01-01

    Objectives. This study evaluated consistency between self-reported values for clinical measures and recorded clinical measures. Methods. Self-reported values were collected for the clinical measures: systolic blood pressure, diastolic blood pressure, glucose level, height, weight, and cholesterol from health risk assessments completed by enrollees in a privately insured cohort. Body mass index (BMI) was computed from reported height and weight. Practitioner recorded values for the clinical me...

  20. System dynamics model of Hubbert Peak for China's oil

    International Nuclear Information System (INIS)

    Tao Zaipu; Li Mingyu

    2007-01-01

    American geophysicist M. King Hubbert in 1956 first introduced a logistic equation to estimate the peak and lifetime production for oil of USA. Since then, a fierce debate ensued on the so-called Hubbert Peak, including also its methodology. This paper proposes to use the generic STELLA model to simulate Hubbert Peak, particularly for the Chinese oil production. This model is demonstrated as being robust. We used three scenarios to estimate the Chinese oil peak: according to scenario 1 of this model, the Hubbert Peak for China's crude oil production appears to be in 2019 with a value of 199.5 million tonnes, which is about 1.1 times the 2005 output. Before the peak comes, Chinese oil output will grow by about 1-2% annually, after the peak, however, the output will fall. By 2040, the annual production of Chinese crude oil would be equivalent to the level of 1990. During the coming 20 years, the crude oil demand of China will probably grow at the rate of 2-3% annually, and the gap between domestic supply and total demand may be more than half of this demand

  1. An Improvement on the Junction Temperature Measurement of Light-Emitting Diodes by using the Peak Shift Method Compared with the Forward Voltage Method

    International Nuclear Information System (INIS)

    He Su-Ming; Wang Jin-Bin; Luo Xiang-Dong; Zhang Bo; Fu Lei; Cheng Li-Wen; Lu Wei

    2012-01-01

    The junction temperature of red, green and blue high power light emitting diodes (LEDs) is measured by using the emission peak shift method and the forward voltage method. Both the emission peak shift and the forward voltage decrease show a linear relationship relative to junction temperature. The linear coefficients of the red, green and blue LEDs for the peak shift method and the forward voltage method range from 0.03 to 0.15 nm/°C and from 1.33 to 3.59 mV/°C, respectively. Compared with the forward voltage method, the peak shift method is almost independent of bias current and sample difference. The variation of the slopes is less than 2% for the peak shift method and larger than 30% for the forward voltage method, when the LEDs are driven by different bias currents. It is indicated that the peak shift method gives better stability than the forward voltage method under different LED working conditions

  2. Evaluation of the shape of the specular peak for high glossy surfaces

    Science.gov (United States)

    Obein, Gaël.; Ouarets, Shiraz; Ged, Guillaume

    2014-02-01

    Gloss is the second most relevant visual attribute of a surface beside its colour. While the colour originates from the wavelength repartition of the reflected light, gloss originates from its angular distribution. When an observer is asked to evaluate the gloss of a surface, he always first orientate his eyes along the specular direction before lightly tilting the examined sample. This means that gloss is located in and around the specular direction, in a peak that is called the specular peak. On the one hand, this peak is flat and broad on matte surfaces on the other hand, it is narrow and sharp on high gloss surfaces. For the late ones, the FWHM of the specular peak is less than 2° which can be quite difficult to measure. We developed a dedicated facility capable of measuring specular peak with a FWHM up to 0,1 °. We measured the evolution of the peak according to the angle of illumination and the specular gloss of the sample in the restricted field of very glossy surface. The facility and peaks measured are presented in the paper. The next step will be to identify the correlations between the peak and the roughness of the sample.

  3. Earthquake hazard zonation using peak ground acceleration (PGA) approach

    International Nuclear Information System (INIS)

    Irwansyah, E; Winarko, E; Rasjid, Z E; Bekti, R D

    2013-01-01

    The objective of this research is to develop seismic hazard area zones in the building infrastructure of the Banda Aceh City Indonesia using peak ground acceleration (PGA) measured using global and local attenuation function. PGA is calculated using attenuation function that describes the correlation between the local ground movement intensity the earthquake magnitude and the distance from the earthquake's epicentre. The data used comes from the earthquake damage catalogue available from the Indonesia meteorology, climatology and geophysics agency (BMKG) with range from year 1973 – 2011. The research methodology consists of six steps, which is developing the grid, calculation of the distance from the epicentre to the centroid of the grid, calculation of PGA values, developing the computer application, plotting the PGA values to the centroid grid, and developing the earthquake hazard zones using kriging algorithm. The conclusion of this research is that the global attenuation function that was developed by [20] can be applied to calculate the PGA values in the city of Banda Aceh. Banda Aceh city in micro scale can be divided into three hazard zones which is low hazard zone with PGA value of 0.8767 gals up to 0.8780 gals, medium hazard zone with PGA values of 0.8781 up to 0.8793 gals and high hazard zone with PGA values of 0.8794 up to 0.8806 gals.

  4. Weak measurements and quantum weak values for NOON states

    Science.gov (United States)

    Rosales-Zárate, L.; Opanchuk, B.; Reid, M. D.

    2018-03-01

    Quantum weak values arise when the mean outcome of a weak measurement made on certain preselected and postselected quantum systems goes beyond the eigenvalue range for a quantum observable. Here, we propose how to determine quantum weak values for superpositions of states with a macroscopically or mesoscopically distinct mode number, that might be realized as two-mode Bose-Einstein condensate or photonic NOON states. Specifically, we give a model for a weak measurement of the Schwinger spin of a two-mode NOON state, for arbitrary N . The weak measurement arises from a nondestructive measurement of the two-mode occupation number difference, which for atomic NOON states might be realized via phase contrast imaging and the ac Stark effect using an optical meter prepared in a coherent state. The meter-system coupling results in an entangled cat-state. By subsequently evolving the system under the action of a nonlinear Josephson Hamiltonian, we show how postselection leads to quantum weak values, for arbitrary N . Since the weak measurement can be shown to be minimally invasive, the weak values provide a useful strategy for a Leggett-Garg test of N -scopic realism.

  5. Measurement Invariance of Expectancy-Value Questionnaire in Physical Education

    Science.gov (United States)

    Zhu, Xihe; Sun, Haichun; Chen, Ang; Ennis, Catherine

    2012-01-01

    Expectancy-Value Questionnaire (EVQ) measures student expectancy beliefs and task values of the domain content (Eccles & Wigfield, 1995). In this study the authors examine measurement invariance of EVQ in the domain of physical education between elementary and middle-school students. Participants included 811 students (3rd-5th grades) from 13…

  6. Cultural Values Predicting Acculturation Orientations: Operationalizing a Quantitative Measure

    Science.gov (United States)

    Ehala, Martin

    2012-01-01

    This article proposes that acculturation orientations are related to two sets of cultural values: utilitarianism (Ut) and traditionalism (Tr). While utilitarian values enhance assimilation, traditional values support language and identity maintenance. It is proposed that the propensity to either end of this value opposition can be measured by an…

  7. A study of diurnal variation in peak expiratory flow rates in healthy adult female subjects in South India

    Directory of Open Access Journals (Sweden)

    Jenny Jayapal

    2014-01-01

    Full Text Available Background: Peak Expiratory Flow Rate (PEFR reflects the strength and condition of respiratory muscles and the degree of airflow limitation in large airways. PEFR shows hour to hour variation that follows a specific pattern in asthmatics and healthy individuals. Adequate data is not available for the diurnal variation in normal individuals who are students in professional courses and had a sedentary life style. Hence, this study was undertaken to study the diurnal variation in peak expiratory flow rates in healthy adult female subjects in South India. Materials and Methods: Peak expiratory flow rate was recorded in 50 adult healthy female students aged 18-23 years and studying in professional courses. Mini Wright′s peak flow meter was used to measure the peak expiratory flow rate. PEFR were recorded at 7-8 a.m., 10-11 a.m., 1-2 p.m., 4-5 p.m., and 7-8 p.m. for two consecutive days. Results: On analysis of PEFR records of individual subjects, it was seen that there was an overall dip in the morning at 7-8 h PEFR, which increased in the daytime, peaking in the afternoon at 1-2 p.m. and eventually decreased in the night. Subjects did not show the peak PEFR values at the same time point, 10% of subjects had a rise in PEFR in the early morning, afternoon (1-2 p.m. peak was observed in 48% subjects and evening (4-5 p.m. peak was observed in 16% subjects. 14% subjects showed a peak in the night time (7-8 p.m. PEFR values. Conclusion: This study provided the preliminary reference data of diurnal variation of peak expiratory flow rate in healthy adults. Since, there is a variation in the peak expiratory flow rate recorded during different time points of the day; hence, to compare the PEFR between individuals it is advisable to record the PEFR at the same time point.

  8. Determination of power peak factor using control rods, ex-core detectors and neural networks

    International Nuclear Information System (INIS)

    Souza, Rose Mary Gomes do Prado

    2005-01-01

    This work presents a methodology based on the artificial neural network technique to predict in real time the power peak factor in a form that can be implemented in reactor protection systems. The neural network inputs were those available in the reactor protection systems, namely, the axial and quadrant power differences obtained from measured ex-core detector signals, and the position of control rods. The response of ex core detector signals was measured in experiments especially performed in the IPEN/MB-01 zero-power reactor. Several reactor states with different power density distribution were obtained by positioning the control rods in different configurations. The power distribution and its peak factor were calculated for each of these reactor states using the Citation code. The obtained results show that the power peak factor correlates well with the control rod position and the quadrant power difference, and with a lesser degree with the axial power differences. The data presented an inherent organisation and could be classified into different classes of power peak factor behaviour as a function of position of control rods, axial power difference and quadrant power difference. The RBF networks were able to identify classes and interpolate the power peak factor values. The relative error for the power peak factor estimation ranged from 0.19 % to 0.67 %, less than the one that was obtained performing a power density distribution map with in-core detectors. It was observed that the positions of control rods bear the detailed and localised information about the power density distribution, and that the axial and the quadrant power difference describe its global variations in the axial and radial directions. The results showed that the RBF and MLP networks produced similar results, and that a neural network correlation can be implemented in power reactor protection systems. (author)

  9. Commonly used reference values underestimate oxygen uptake in healthy, 50-year-old Swedish women.

    Science.gov (United States)

    Genberg, M; Andrén, B; Lind, L; Hedenström, H; Malinovschi, A

    2018-01-01

    Cardiopulmonary exercise testing (CPET) is the gold standard among clinical exercise tests. It combines a conventional stress test with measurement of oxygen uptake (V O 2 ) and CO 2 production. No validated Swedish reference values exist, and reference values in women are generally understudied. Moreover, the importance of achieved respiratory exchange ratio (RER) and the significance of breathing reserve (BR) at peak exercise in healthy individuals are poorly understood. We compared V O 2 at maximal load (peakV O 2 ) and anaerobic threshold (V O 2@ AT ) in healthy Swedish individuals with commonly used reference values, taking gender into account. Further, we analysed maximal workload and peakV O 2 with regard to peak RER and BR. In all, 181 healthy, 50-year-old individuals (91 women) performed CPET. PeakV O 2 was best predicted using Jones et al. (100·5%), while SHIP reference values underestimated peakV O 2 most: 112·5%. Furthermore, underestimation of peakV O 2 in women was found for all studied reference values (P 1·1 (2 328·7 versus 2 176·7 ml min -1 , P = 0·11). Lower BR (≤30%) related to significantly higher peakV O 2 (Pvalues underestimated oxygen uptake in women. No evidence for demanding RER > 1·1 in healthy individuals was found. A lowered BR is probably a normal response to higher workloads in healthy individuals. © 2016 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  10. Measurement of disintegration rates of 60Co volume sources by the sum-peak method

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1991-01-01

    The sum-peak method has been applied to the determination of the disintegration rates of 60 Co volume sources (1.05 x 10 4 Bq, 1.05 x 10 3 Bq and 1.05 x 10 2 Bq, in 100-ml polyethylene bottles) by using a NaI(Tl) detector of a diameter of 50 mm and a height of 50 mm. The experimental results showed that decreasing the disintegration rates resulted in enlarged underestimation in comparison with the true disintegration rates. It was presumed that the underestimations of the disintegration rates determined by the sum-peak method resulted from the overestimations of the areas under the sum peaks caused by the overlap of the area under the Compton scattering of the γ-ray (2614 keV) emitted from a naturally occurring radionuclide 208 Tl under the sum peaks. (author)

  11. Surface potential measurement of insulators in negative-ion implantation by secondary electron energy-peak shift

    International Nuclear Information System (INIS)

    Nagumo, Shoji; Toyota, Yoshitaka; Tsuji, Hiroshi; Gotoh, Yasuhito; Ishikawa, Junzo; Sakai, Shigeki; Tanjyo, Masayasu; Matsuda, Kohji.

    1993-01-01

    Negative-ion implantation is expected to realize charge-up free implantation. In this article, about a way to specify surface potential of negative-ion implanted insulator by secondary-electron-energy distribution, its principle and preliminary experimental results are described. By a measuring system with retarding field type energy analyzer, energy distribution of secondary electron from insulator of Fused Quartz in negative-carbon-ion implantation was measured. As a result the peak-shift of its energy distribution resulted according with the surface potential of insulator. It was found that surface potential of insulator is negatively charged by only several volts. Thus, negative-ion implanted insulator reduced its surface charge-up potential (without any electron supply). Therefore negative-ion implantation is considered to be much more effective method than conventional positive-ion implantation. (author)

  12. [Implicit value judgments in the measurement of health inequalities].

    Science.gov (United States)

    Harper, Sam; King, Nicholas B; Meersman, Stephen C; E Reichman, Marsha; Breen, Nancy; Lynch, John

    2014-04-01

    Quantitative estimates of the magnitude, direction, and rate of change of health inequalities play a crucial role in creating and assessing policies aimed at eliminating the disproportionate burden of disease in disadvantaged populations. It is generally assumed that the measurement of health inequalities is a value-neutral process, providing objective data that are then interpreted using normative judgments about whether a particular distribution of health is just, fair, or socially acceptable. We discuss five examples in which normative judgments play a role in the measurement process itself, through either the selection of one measurement strategy to the exclusion of others or the selection of the type, significance, or weight assigned to the variables being measured. Overall, we find that many commonly used measures of inequality are value laden and that the normative judgments implicit in these measures have important consequences for interpreting and responding to health inequalities. Because values implicit in the generation of health inequality measures may lead to radically different interpretations of the same underlying data,we urge researchers to explicitly consider and transparently discuss the normative judgments underlying their measures. We also urge policymakers and other consumers of health inequalities data to pay close attention to the measures on which they base their assessments of current and future health policies.

  13. Implicit value judgments in the measurement of health inequalities.

    Science.gov (United States)

    Harper, Sam; King, Nicholas B; Meersman, Stephen C; Reichman, Marsha E; Breen, Nancy; Lynch, John

    2010-03-01

    Quantitative estimates of the magnitude, direction, and rate of change of health inequalities play a crucial role in creating and assessing policies aimed at eliminating the disproportionate burden of disease in disadvantaged populations. It is generally assumed that the measurement of health inequalities is a value-neutral process, providing objective data that are then interpreted using normative judgments about whether a particular distribution of health is just, fair, or socially acceptable. We discuss five examples in which normative judgments play a role in the measurement process itself, through either the selection of one measurement strategy to the exclusion of others or the selection of the type, significance, or weight assigned to the variables being measured. Overall, we find that many commonly used measures of inequality are value laden and that the normative judgments implicit in these measures have important consequences for interpreting and responding to health inequalities. Because values implicit in the generation of health inequality measures may lead to radically different interpretations of the same underlying data, we urge researchers to explicitly consider and transparently discuss the normative judgments underlying their measures. We also urge policymakers and other consumers of health inequalities data to pay close attention to the measures on which they base their assessments of current and future health policies.

  14. Peak season plant activity shift towards spring is reflected by increasing carbon uptake by extratropical ecosystems.

    Science.gov (United States)

    Gonsamo, Alemu; Chen, Jing M; Ooi, Ying W

    2018-05-01

    Climate change is lengthening the growing season of the Northern Hemisphere extratropical terrestrial ecosystems, but little is known regarding the timing and dynamics of the peak season of plant activity. Here, we use 34-year satellite normalized difference vegetation index (NDVI) observations and atmospheric CO 2 concentration and δ 13 C isotope measurements at Point Barrow (Alaska, USA, 71°N) to study the dynamics of the peak of season (POS) of plant activity. Averaged across extratropical (>23°N) non-evergreen-dominated pixels, NDVI data show that the POS has advanced by 1.2 ± 0.6 days per decade in response to the spring-ward shifts of the start (1.0 ± 0.8 days per decade) and end (1.5 ± 1.0 days per decade) of peak activity, and the earlier onset of the start of growing season (1.4 ± 0.8 days per decade), while POS maximum NDVI value increased by 7.8 ± 1.8% for 1982-2015. Similarly, the peak day of carbon uptake, based on calculations from atmospheric CO 2 concentration and δ 13 C data, is advancing by 2.5 ± 2.6 and 4.3 ± 2.9 days per decade, respectively. POS maximum NDVI value shows strong negative relationships (p POS days. Given that the maximum solar irradiance and day length occur before the average POS day, the earlier occurrence of peak plant activity results in increased plant productivity. Both the advancing POS day and increasing POS vegetation greenness are consistent with the shifting peak productivity towards spring and the increasing annual maximum values of gross and net ecosystem productivity simulated by coupled Earth system models. Our results further indicate that the decline in autumn NDVI is contributing the most to the overall browning of the northern high latitudes (>50°N) since 2011. The spring-ward shift of peak season plant activity is expected to disrupt the synchrony of biotic interaction and exert strong biophysical feedbacks on climate by modifying the surface albedo and energy budget. © 2017

  15. Adam Smith's Concept of Labour: Value or Measure?

    OpenAIRE

    Adolfo Rodriguez-Herrera

    2014-01-01

    The terminology employed by Smith to refer to value and measure of value is used in his time with imprecision, which has led to different interpretations about his position on these issues. It is no coincidence that Smith is considered the father of the labour theory of value developed by David Ricardo and Karl Marx and simultaneously of the cost-of-production theory of value developed by John Stuart Mill and Alfred Marshall. This paper reviews the concepts developed by Smith to formulate his...

  16. Measure-valued solutions to the complete Euler system revisited

    Science.gov (United States)

    Březina, Jan; Feireisl, Eduard

    2018-06-01

    We consider the complete Euler system describing the time evolution of a general inviscid compressible fluid. We introduce a new concept of measure-valued solution based on the total energy balance and entropy inequality for the physical entropy without any renormalization. This class of so-called dissipative measure-valued solutions is large enough to include the vanishing dissipation limits of the Navier-Stokes-Fourier system. Our main result states that any sequence of weak solutions to the Navier-Stokes-Fourier system with vanishing viscosity and heat conductivity coefficients generates a dissipative measure-valued solution of the Euler system under some physically grounded constitutive relations. Finally, we discuss the same asymptotic limit for the bi-velocity fluid model introduced by H.Brenner.

  17. Peak-interviewet

    DEFF Research Database (Denmark)

    Raalskov, Jesper; Warming-Rasmussen, Bent

    Peak-interviewet er en særlig effektiv metode til at gøre ubevidste menneskelige ressourcer bevidste. Fokuspersonen (den interviewede) interviewes om en selvvalgt, personlig succesoplevelse. Terapeuten/coachen (intervieweren) spørger ind til processen, som ledte hen til denne succes. Herved afdæk...... fokuspersonen ønsker at tage op (nye mål eller nye processer). Nærværende workingpaper beskriver, hvad der menes med et peak-interview, peakinterviwets teoretiske fundament samt metodikken til at foretage et tillidsfuldt og effektiv peak-interview....

  18. Different methods of measuring ADC values in normal human brain

    International Nuclear Information System (INIS)

    Wei Youping; Sheng Junkang; Zhang Caiyuan

    2009-01-01

    Objective: To investigate better method of measuring ADC values of normal brain, and provide reference for further research. Methods: Twenty healthy people's MR imaging were reviewed. All of them underwent routine MRI scans and echo-planar diffusion-weighted imaging (DWI), and ADC maps were reconstructed on work station. Six regions of interest (ROI) were selected for each object, the mean ADC values were obtained for each position on DWI and ADC maps respectively. Results: On the anisotropic DWI map calculated in the hypothalamus, ADC M , ADC P , ADC S values were no significant difference (P>0.05), in the frontal white matter and internal capsule hindlimb, there was a significant difference (P ave value exist significant difference to direct measurement on the anisotropic (isotropic) ADC map (P<0.001). Conclusion: Diffusion of water in the frontal white matter and internal capsule are anisotropic, but it is isotropic in the hypothalamus; different quantitative methods of diffusion measurement of 4ADC values have significant difference, but ADC values calculated through the DWI map is more accurate, quantitative diffusion study of brain tissue should also consider the diffusion measurement method. (authors)

  19. 'Peak oil' or 'peak demand'?

    International Nuclear Information System (INIS)

    Chevallier, Bruno; Moncomble, Jean-Eudes; Sigonney, Pierre; Vially, Rolland; Bosseboeuf, Didier; Chateau, Bertrand

    2012-01-01

    This article reports a workshop which addressed several energy issues like the objectives and constraints of energy mix scenarios, the differences between the approaches in different countries, the cost of new technologies implemented for this purposes, how these technologies will be developed and marketed, which will be the environmental and societal acceptability of these technical choices. Different aspects and issues have been more precisely presented and discussed: the peak oil, development of shale gases and their cost (will non conventional hydrocarbons modify the peak oil and be socially accepted?), energy efficiency (its benefits, its reality in France and other countries, its position in front of the challenge of energy transition), and strategies in the transport sector (challenges for mobility, evolution towards a model of sustainable mobility)

  20. Calculation of the detection limits for radionuclides identified in gamma-ray spectra based on post-processing peak analysis results.

    Science.gov (United States)

    Korun, M; Vodenik, B; Zorko, B

    2018-03-01

    A new method for calculating the detection limits of gamma-ray spectrometry measurements is presented. The method is applicable for gamma-ray emitters, irrespective of the influences of the peaked background, the origin of the background and the overlap with other peaks. It offers the opportunity for multi-gamma-ray emitters to calculate the common detection limit, corresponding to more peaks. The detection limit is calculated by approximating the dependence of the uncertainty in the indication on its value with a second-order polynomial. In this approach the relation between the input quantities and the detection limit are described by an explicit expression and can be easy investigated. The detection limit is calculated from the data usually provided by the reports of peak-analyzing programs: the peak areas and their uncertainties. As a result, the need to use individual channel contents for calculating the detection limit is bypassed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Comparison of the values of measured hydratation of sporting youths with normative values

    Directory of Open Access Journals (Sweden)

    Petr Kutáč

    2013-06-01

    Full Text Available BACKROUND: When measuring body composition, we monitor the fractionalization of body weight and the share of the individual elements in its aggregate value. The total body water (TBW is a very important element in addition to the share of body fat (BF, muscle mass and bone minerals. Water is the largest element of the body weight and its sufficient amount (organism hydration is a condition for maintaining the physiological functions of the person and thus has an immediate effect on the health of the individual. OBJECTIVE: The aim of the study is to check the standard values of the percentage share of the representation of the total body water in the total body weight in different age groups of sporting youths using the tetrapolar bio-impedance Tanita 418 MA scale. METHODS: The research group included a total of 532 individuals (332 men and 200 women at the age from 12 to 17 years. They were individuals with regular physical activity and without any health problems. The measurement was carried out using the tetrapolar bio-impedance TANITA 418 MA scale. The confidence interval at the reliability level of .99 was used to define the range of the standard values of the percentage share of the total body water representation. The normalization index Ni was used to compare the mean values of the total body water representation with the reference file. RESULTS: The mean values of the TBW representation in boys ranged from 61.75 to 64.34% and in girls from 55.51 to 58.69%, always in relation to the age. The value of the upper bound of (95% the confidence interval of the Tanita 418 MA device software did not exceed the lower bound of the standard (65% in any of the monitored files. CONCLUSIONS: The results showed significant gender differences in the total body water representation that, however, the standard of the used device does not respect. The standard values are set high which was also confirmed by the comparison of our results with other studies

  2. Respiratory variation in peak aortic velocity accurately predicts fluid responsiveness in children undergoing neurosurgery under general anesthesia.

    Science.gov (United States)

    Morparia, Kavita G; Reddy, Srijaya K; Olivieri, Laura J; Spaeder, Michael C; Schuette, Jennifer J

    2018-04-01

    The determination of fluid responsiveness in the critically ill child is of vital importance, more so as fluid overload becomes increasingly associated with worse outcomes. Dynamic markers of volume responsiveness have shown some promise in the pediatric population, but more research is needed before they can be adopted for widespread use. Our aim was to investigate effectiveness of respiratory variation in peak aortic velocity and pulse pressure variation to predict fluid responsiveness, and determine their optimal cutoff values. We performed a prospective, observational study at a single tertiary care pediatric center. Twenty-one children with normal cardiorespiratory status undergoing general anesthesia for neurosurgery were enrolled. Respiratory variation in peak aortic velocity (ΔVpeak ao) was measured both before and after volume expansion using a bedside ultrasound device. Pulse pressure variation (PPV) value was obtained from the bedside monitor. All patients received a 10 ml/kg fluid bolus as volume expansion, and were qualified as responders if stroke volume increased >15% as a result. Utility of ΔVpeak ao and PPV and to predict responsiveness to volume expansion was investigated. A baseline ΔVpeak ao value of greater than or equal to 12.3% best predicted a positive response to volume expansion, with a sensitivity of 77%, specificity of 89% and area under receiver operating characteristic curve of 0.90. PPV failed to demonstrate utility in this patient population. Respiratory variation in peak aortic velocity is a promising marker for optimization of perioperative fluid therapy in the pediatric population and can be accurately measured using bedside ultrasonography. More research is needed to evaluate the lack of effectiveness of pulse pressure variation for this purpose.

  3. Measurement and estimation of dew point for SNG. [Comparison of calculated and measured values

    Energy Technology Data Exchange (ETDEWEB)

    Furuyama, Y.

    1974-08-01

    Toho Gas measured and estimated SNG dew points in high-pressure deliveries by calculating the theoretical values by the high-pressure gas-liquid equilibrium theory using the pressure-extrapolation method to reach K = 1, and the BWR method to estimate fugacity, then verifying these values experimentally. The experimental values were measured at 161.7 to 367.5 psi using the conventional static and circulation methods, in addition to a newly developed method consisting of circulating a known composition of gas mixtures, partially freezing them, and monitoring the dew point by observing the droplets on a mirror cooled by blowing liquid nitrogen. Good agreement was found between the calculated and the experimental values.

  4. A method for valuing architecture-based business transformation and measuring the value of solutions architecture

    OpenAIRE

    Slot, R.G.

    2010-01-01

    Enterprise and Solution Architecture are key in today’s business environment. It is surprising that the foundation and business case for these activities are nonexistent; the financial value for the business of these activities is largely undetermined. To determine business value of enterprise and solution architecture, this thesis shows how to measure and quantify, in business terms, the value of enterprise architecture-based on business transformation and the value of solution architecture.

  5. Peak Satellite-to-Earth Data Rates Derived From Measurements of a 20 Gbps Bread-Board Modem

    Science.gov (United States)

    Landon, David G.; Simons, Rainee N.; Wintucky, Edwin G.; Sun, Jun Y.; Winn, James S.; Laraway, Stephen A.; McIntire, William K.; Metz, John L.; Smith, Francis J.

    2011-01-01

    A prototype data link using a Ka-band space qualified, high efficiency 200 W TWT amplifier and a bread-board modem emulator were created to explore the feasibility of very high speed communications in satellite-to-earth applications. Experiments were conducted using a DVB-S2-like waveform with modifications to support up to 20 Gbps through the addition of 128-Quadrature Amplitude Modulation (QAM). Limited by the bandwidth of the amplifier, a constant peak symbol rate of 3.2 Giga-symbols/sec was selected and the modulation order was varied to explore what peak data rate might be supported by an RF link through this amplifier. Using 128-QAM, an implementation loss of 3 dB was observed at 20 Gbps, and the loss decreased as data rate or bandwidth were reduced. Building on this measured data, realistic link budget calculations were completed. Low-Earth orbit (LEO) missions based on this TWTA with reasonable hardware assumptions and antenna sizing are found to be bandwidth-limited, rather than power-limited, making the spectral efficiency of 9/10-rate encoded 128-QAM very attractive. Assuming a bandwidth allocation of 1 GHz, these computations indicate that low-Earth orbit vehicles could achieve data rates up to 5 Gbps-an order of magnitude beyond the current state-of-practice, yet still within the processing power of a current FPGA-based software-defined modem. The measured performance results and a description of the experimental setup are presented to support these conclusions.

  6. KiDS-450: cosmological constraints from weak-lensing peak statistics - II: Inference from shear peaks using N-body simulations

    Science.gov (United States)

    Martinet, Nicolas; Schneider, Peter; Hildebrandt, Hendrik; Shan, HuanYuan; Asgari, Marika; Dietrich, Jörg P.; Harnois-Déraps, Joachim; Erben, Thomas; Grado, Aniello; Heymans, Catherine; Hoekstra, Henk; Klaes, Dominik; Kuijken, Konrad; Merten, Julian; Nakajima, Reiko

    2018-02-01

    We study the statistics of peaks in a weak-lensing reconstructed mass map of the first 450 deg2 of the Kilo Degree Survey (KiDS-450). The map is computed with aperture masses directly applied to the shear field with an NFW-like compensated filter. We compare the peak statistics in the observations with that of simulations for various cosmologies to constrain the cosmological parameter S_8 = σ _8 √{Ω _m/0.3}, which probes the (Ωm, σ8) plane perpendicularly to its main degeneracy. We estimate S8 = 0.750 ± 0.059, using peaks in the signal-to-noise range 0 ≤ S/N ≤ 4, and accounting for various systematics, such as multiplicative shear bias, mean redshift bias, baryon feedback, intrinsic alignment, and shear-position coupling. These constraints are ˜ 25 per cent tighter than the constraints from the high significance peaks alone (3 ≤ S/N ≤ 4) which typically trace single-massive haloes. This demonstrates the gain of information from low-S/N peaks. However, we find that including S/N KiDS-450. Combining shear peaks with non-tomographic measurements of the shear two-point correlation functions yields a ˜20 per cent improvement in the uncertainty on S8 compared to the shear two-point correlation functions alone, highlighting the great potential of peaks as a cosmological probe.

  7. Automatic Peak Selection by a Benjamini-Hochberg-Based Algorithm

    KAUST Repository

    Abbas, Ahmed; Kong, Xin-Bing; Liu, Zhi; Jing, Bing-Yi; Gao, Xin

    2013-01-01

    A common issue in bioinformatics is that computational methods often generate a large number of predictions sorted according to certain confidence scores. A key problem is then determining how many predictions must be selected to include most of the true predictions while maintaining reasonably high precision. In nuclear magnetic resonance (NMR)-based protein structure determination, for instance, computational peak picking methods are becoming more and more common, although expert-knowledge remains the method of choice to determine how many peaks among thousands of candidate peaks should be taken into consideration to capture the true peaks. Here, we propose a Benjamini-Hochberg (B-H)-based approach that automatically selects the number of peaks. We formulate the peak selection problem as a multiple testing problem. Given a candidate peak list sorted by either volumes or intensities, we first convert the peaks into p-values and then apply the B-H-based algorithm to automatically select the number of peaks. The proposed approach is tested on the state-of-the-art peak picking methods, including WaVPeak [1] and PICKY [2]. Compared with the traditional fixed number-based approach, our approach returns significantly more true peaks. For instance, by combining WaVPeak or PICKY with the proposed method, the missing peak rates are on average reduced by 20% and 26%, respectively, in a benchmark set of 32 spectra extracted from eight proteins. The consensus of the B-H-selected peaks from both WaVPeak and PICKY achieves 88% recall and 83% precision, which significantly outperforms each individual method and the consensus method without using the B-H algorithm. The proposed method can be used as a standard procedure for any peak picking method and straightforwardly applied to some other prediction selection problems in bioinformatics. The source code, documentation and example data of the proposed method is available at http://sfb.kaust.edu.sa/pages/software.aspx. © 2013

  8. Automatic Peak Selection by a Benjamini-Hochberg-Based Algorithm

    KAUST Repository

    Abbas, Ahmed

    2013-01-07

    A common issue in bioinformatics is that computational methods often generate a large number of predictions sorted according to certain confidence scores. A key problem is then determining how many predictions must be selected to include most of the true predictions while maintaining reasonably high precision. In nuclear magnetic resonance (NMR)-based protein structure determination, for instance, computational peak picking methods are becoming more and more common, although expert-knowledge remains the method of choice to determine how many peaks among thousands of candidate peaks should be taken into consideration to capture the true peaks. Here, we propose a Benjamini-Hochberg (B-H)-based approach that automatically selects the number of peaks. We formulate the peak selection problem as a multiple testing problem. Given a candidate peak list sorted by either volumes or intensities, we first convert the peaks into p-values and then apply the B-H-based algorithm to automatically select the number of peaks. The proposed approach is tested on the state-of-the-art peak picking methods, including WaVPeak [1] and PICKY [2]. Compared with the traditional fixed number-based approach, our approach returns significantly more true peaks. For instance, by combining WaVPeak or PICKY with the proposed method, the missing peak rates are on average reduced by 20% and 26%, respectively, in a benchmark set of 32 spectra extracted from eight proteins. The consensus of the B-H-selected peaks from both WaVPeak and PICKY achieves 88% recall and 83% precision, which significantly outperforms each individual method and the consensus method without using the B-H algorithm. The proposed method can be used as a standard procedure for any peak picking method and straightforwardly applied to some other prediction selection problems in bioinformatics. The source code, documentation and example data of the proposed method is available at http://sfb.kaust.edu.sa/pages/software.aspx. © 2013

  9. Peak-counts blood flow model-errors and limitations

    International Nuclear Information System (INIS)

    Mullani, N.A.; Marani, S.K.; Ekas, R.D.; Gould, K.L.

    1984-01-01

    The peak-counts model has several advantages, but its use may be limited due to the condition that the venous egress may not be negligible at the time of peak-counts. Consequently, blood flow measurements by the peak-counts model will depend on the bolus size, bolus duration, and the minimum transit time of the bolus through the region of interest. The effect of bolus size on the measurement of extraction fraction and blood flow was evaluated by injecting 1 to 30ml of rubidium chloride in the femoral vein of a dog and measuring the myocardial activity with a beta probe over the heart. Regional blood flow measurements were not found to vary with bolus sizes up to 30ml. The effect of bolus duration was studied by injecting a 10cc bolus of tracer at different speeds in the femoral vein of a dog. All intravenous injections undergo a broadening of the bolus duration due to the transit time of the tracer through the lungs and the heart. This transit time was found to range from 4-6 second FWHM and dominates the duration of the bolus to the myocardium for up to 3 second injections. A computer simulation has been carried out in which the different parameters of delay time, extraction fraction, and bolus duration can be changed to assess the errors in the peak-counts model. The results of the simulations show that the error will be greatest for short transit time delays and for low extraction fractions

  10. Quantitative assessment of thallium myocardial washout rate: Importance of peak heart rate and lung thallium uptake in defining normal values

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Kozuka, Takahiro; Saito, Muneyasu; Sumiyoshi, Tetsuya; National Cardiovascular Center, Suita, Osaka

    1987-01-01

    Traditionally, the results of exercise thallium scintigraphy were interpreted by transient defect analysis using initial and delayed images. Recently, washout rate analysis has been used for the relative quantification of exercise thallium scintigraphy. A diffuse slow washout from all myocardial regions has been defined as the indicator of extensive coronary artery disease. However, slow washout has occasionally been observed in normal cases and in healthy myocardial segments which are not supplied by a stenosed artery in patients with single or double vessel disease. We evaluate the factors influencing washout rate in 100 normal patients and 63 patients with angina pectoris (33 cases of single vessel disease and 30 cases of double vessel disease). The washout rates were calculated using circumferential profile analysis. In normal patients, washout rate was closely related to peak heart rate (r=0.72) and inversely related to lung thallium uptake (r=-0.56). A diffuse slow washout was observed in seven (7%) of 100 normal patients, six (18%) of 33 cases of single vessel disease and eight (24%) of 30 cases of double vessel disease. The patients with diffuse slow washout showed significantly higher lung thallium uptake values and lower peak heart rates than those without diffuse slow washout (P<0.01). Thus, this false positive slow washout should be considered in the interpretation of quantitative exercise thallium scintigraphy. (orig.)

  11. Gamma-ray peak shapes from cadmium zinc telluride detectors

    Energy Technology Data Exchange (ETDEWEB)

    Namboodiri, M.N.; Lavietes, A.D.; McQuaid, J.H.

    1996-09-01

    We report the results of a study of the peak shapes in the gamma spectra measured using several 5 x 5 x 5 mm{sup 3} cadmium zinc telluride (CZT) detectors. A simple parameterization involving a Gaussian and an exponential low energy tail describes the peak shapes sell. We present the variation of the parameters with gamma energy. This type of information is very useful in the analysis of complex gamma spectra consisting of many peaks.

  12. factors influencing peak expiratory flow in teenage boys

    African Journals Online (AJOL)

    smoked. Regression analysis suggested peak flow differenct.s ... Medical Research Council Centre for Molecular and Cellular Biology, Department ... J leasure of lung function and a tool for asthma management.'.2 ... by the subjects were assigned a numerical value based on how .... Our data differ marginally from data.

  13. Identification of peaks in multidimensional coincidence {gamma}-ray spectra

    Energy Technology Data Exchange (ETDEWEB)

    Morhac, Miroslav E-mail: fyzimiro@savba.sk; Kliman, Jan; Matousek, Vladislav; Veselsky, Martin; Turzo, Ivan

    2000-03-21

    In the paper a new algorithm to find peaks in two, three and multidimensional spectra, measured in large multidetector {gamma}-ray arrays, is derived. Given the dimension m, the algorithm is selective to m-fold coincidence peaks. It is insensitive to intersections of lower-fold coincidences, hereinafter called ridges.

  14. Identification of peaks in multidimensional coincidence γ-ray spectra

    International Nuclear Information System (INIS)

    Morhac, Miroslav; Kliman, Jan; Matousek, Vladislav; Veselsky, Martin; Turzo, Ivan

    2000-01-01

    In the paper a new algorithm to find peaks in two, three and multidimensional spectra, measured in large multidetector γ-ray arrays, is derived. Given the dimension m, the algorithm is selective to m-fold coincidence peaks. It is insensitive to intersections of lower-fold coincidences, hereinafter called ridges

  15. Peak experiences of psilocybin users and non-users.

    Science.gov (United States)

    Cummins, Christina; Lyke, Jennifer

    2013-01-01

    Maslow (1970) defined peak experiences as the most wonderful experiences of a person's life, which may include a sense of awe, well-being, or transcendence. Furthermore, recent research has suggested that psilocybin can produce experiences subjectively rated as uniquely meaningful and significant (Griffiths et al. 2006). It is therefore possible that psilocybin may facilitate or change the nature of peak experiences in users compared to non-users. This study was designed to compare the peak experiences of psilocybin users and non-users, to evaluate the frequency of peak experiences while under the influence of psilocybin, and to assess the perceived degree of alteration of consciousness during these experiences. Participants were recruited through convenience and snowball sampling from undergraduate classes and at a musical event. Participants were divided into three groups, those who reported a peak experience while under the influence of psilocybin (psilocybin peak experience: PPE), participants who had used psilocybin but reported their peak experiences did not occur while they were under the influence of psilocybin (non-psilocybin peak experience: NPPE), and participants who had never used psilocybin (non-user: NU). A total of 101 participants were asked to think about their peak experiences and complete a measure evaluating the degree of alteration of consciousness during that experience. Results indicated that 47% of psilocybin users reported their peak experience occurred while using psilocybin. In addition, there were significant differences among the three groups on all dimensions of alteration of consciousness. Future research is necessary to identify factors that influence the peak experiences of psilocybin users in naturalistic settings and contribute to the different characteristics of peak experiences of psilocybin users and non-users.

  16. Power peaking nuclear reliability factors

    International Nuclear Information System (INIS)

    Hassan, H.A.; Pegram, J.W.; Mays, C.W.; Romano, J.J.; Woods, J.J.; Warren, H.D.

    1977-11-01

    The Calculational Nuclear Reliability Factor (CNRF) assigned to the limiting power density calculated in reactor design has been determined. The CNRF is presented as a function of the relative power density of the fuel assembly and its radial local. In addition, the Measurement Nuclear Reliability Factor (MNRF) for the measured peak hot pellet power in the core has been evaluated. This MNRF is also presented as a function of the relative power density and radial local within the fuel assembly

  17. Peak Dose Assessment for Proposed DOE-PPPO Authorized Limits

    International Nuclear Information System (INIS)

    Maldonado, Delis

    2012-01-01

    The Oak Ridge Institute for Science and Education (ORISE), a U.S. Department of Energy (DOE) prime contractor, was contracted by the DOE Portsmouth/Paducah Project Office (DOE-PPPO) to conduct a peak dose assessment in support of the Authorized Limits Request for Solid Waste Disposal at Landfill C-746-U at the Paducah Gaseous Diffusion Plant (DOE-PPPO 2011a). The peak doses were calculated based on the DOE-PPPO Proposed Single Radionuclides Soil Guidelines and the DOE-PPPO Proposed Authorized Limits (AL) Volumetric Concentrations available in DOE-PPPO 2011a. This work is provided as an appendix to the Dose Modeling Evaluations and Technical Support Document for the Authorized Limits Request for the C-746-U Landfill at the Paducah Gaseous Diffusion Plant, Paducah, Kentucky (ORISE 2012). The receptors evaluated in ORISE 2012 were selected by the DOE-PPPO for the additional peak dose evaluations. These receptors included a Landfill Worker, Trespasser, Resident Farmer (onsite), Resident Gardener, Recreational User, Outdoor Worker and an Offsite Resident Farmer. The RESRAD (Version 6.5) and RESRAD-OFFSITE (Version 2.5) computer codes were used for the peak dose assessments. Deterministic peak dose assessments were performed for all the receptors and a probabilistic dose assessment was performed only for the Offsite Resident Farmer at the request of the DOE-PPPO. In a deterministic analysis, a single input value results in a single output value. In other words, a deterministic analysis uses single parameter values for every variable in the code. By contrast, a probabilistic approach assigns parameter ranges to certain variables, and the code randomly selects the values for each variable from the parameter range each time it calculates the dose (NRC 2006). The receptor scenarios, computer codes and parameter input files were previously used in ORISE 2012. A few modifications were made to the parameter input files as appropriate for this effort. Some of these changes

  18. Extreme value theory in emerging markets: Evidence from the Montenegrin stock exchange

    Directory of Open Access Journals (Sweden)

    Cerović Julija

    2015-01-01

    Full Text Available The concept of Value at Risk(VaR estimates the maximum loss of a financial position at a given time for a given probability. This paper considers the adequacy of the methods that are the basis of extreme value theory in the Montenegrin emerging market before and during the global financial crisis. In particular, the purpose of the paper is to investigate whether the peaks-over-threshold method outperforms the block maxima method in evaluation of Value at Risk in emerging stock markets such as the Montenegrin market. The daily return of the Montenegrin stock market index MONEX20 is analyzed for the period January 2004 - February 2014. Results of the Kupiec test show that the peaks-over-threshold method is significantly better than the block maxima method, but both methods fail to pass the Christoffersen independence test and joint test due to the lack of accuracy in exception clustering when measuring Value at Risk. Although better, the peaks-over-threshold method still cannot be treated as an accurate VaR model for the Montenegrin frontier stock market.

  19. Patients’ perceived value of pharmacy quality measures: a mixed-methods study

    Science.gov (United States)

    Shiyanbola, Olayinka O; Mort, Jane R

    2015-01-01

    Objective To describe patients’ perceived value and use of quality measures in evaluating and choosing community pharmacies. Design Focus group methodology was combined with a survey tool. During the focus groups, participants assessed the value of the Pharmacy Quality Alliance's quality measures in evaluating and choosing a pharmacy. Also, participants completed questionnaires rating their perceived value of quality measures in evaluating a pharmacy (1 being low value and 5 being high) or choosing a pharmacy (yes/no). Thematic analysis and descriptive statistics were used to analyse the focus groups and surveys, respectively. Setting Semistructured focus groups were conducted in a private meeting space of an urban and a rural area of a Mid-western State in the USA. Participants Thirty-four adults who filled prescription medications in community pharmacies for a chronic illness were recruited in community pharmacies, senior centres and public libraries. Results While comments indicated that all measures were important, medication safety measures (eg, drug-drug interactions) were valued more highly than others. Rating of quality measure utility in evaluating a pharmacy ranged from a mean of 4.88 (‘drug-drug interactions’) to a mean of 4.0 (‘absence of controller therapy for patients with asthma’). Patients were hesitant to use quality information in choosing a pharmacy (depending on the participant's location) but might consider if moving to a new area or having had a negative pharmacy experience. Use of select quality measures to choose a pharmacy ranged from 97.1% of participants using ‘drug-drug interactions’ (medication safety measure) to 55.9% using ‘absence of controller therapy for patients with asthma’. Conclusions The study participants valued quality measures in evaluating and selecting a community pharmacy, with medication safety measures valued highest. The participants reported that the quality measures would not typically cause a

  20. A New Measure of Traditional Values Across Cultures: China and Russia Compared

    Directory of Open Access Journals (Sweden)

    Robert J. Taormina

    2016-10-01

    Full Text Available A new measure of adherence to traditional values was created with the objective of facilitating research within and across cultures and nations. The measure was tested in China (N = 321 and Russia (N = 314 and factor analysis of the data revealed two subscales named Personal Traditional Values (10 items and Public Traditional Values (6 items. Empirical psychometric testing of the overall 16-item measure and the two subscales strongly supported the validity and reliability of all three measures. Means comparisons conducted to assess how well the measures could be used for cross-cultural comparisons revealed the Russians somewhat more than the Chinese living by traditional values overall, both nations about equal on living according to traditional values in their personal lives, and the Russians significantly more inclined to abide by traditional values in public. Also tested were several social and psychological variables as theoretical predictors of living by traditional values, and Life Satisfaction was tested as a possible correlate of living according to traditional values. Regression analyses on the combined data confirmed that Family Emotional Support, Conscientiousness, Collectivism, and Age were all significant positive predictors of living by traditional values. Additional regressions also found some unique predictors for each nation. These findings and the results of the parametric tests support the use of the new scales for measuring traditional values both within and across cultures.

  1. Comparison of measurement- and proxy-based Vs30 values in California

    Science.gov (United States)

    Yong, Alan K.

    2016-01-01

    This study was prompted by the recent availability of a significant amount of openly accessible measured VS30 values and the desire to investigate the trend of using proxy-based models to predict VS30 in the absence of measurements. Comparisons between measured and model-based values were performed. The measured data included 503 VS30 values collected from various projects for 482 seismographic station sites in California. Six proxy-based models—employing geologic mapping, topographic slope, and terrain classification—were also considered. Included was a new terrain class model based on the Yong et al. (2012) approach but recalibrated with updated measured VS30 values. Using the measured VS30 data as the metric for performance, the predictive capabilities of the six models were determined to be statistically indistinguishable. This study also found three models that tend to underpredict VS30 at lower velocities (NEHRP Site Classes D–E) and overpredict at higher velocities (Site Classes B–C).

  2. The spatial resolution of epidemic peaks.

    Directory of Open Access Journals (Sweden)

    Harriet L Mills

    2014-04-01

    Full Text Available The emergence of novel respiratory pathogens can challenge the capacity of key health care resources, such as intensive care units, that are constrained to serve only specific geographical populations. An ability to predict the magnitude and timing of peak incidence at the scale of a single large population would help to accurately assess the value of interventions designed to reduce that peak. However, current disease-dynamic theory does not provide a clear understanding of the relationship between: epidemic trajectories at the scale of interest (e.g. city; population mobility; and higher resolution spatial effects (e.g. transmission within small neighbourhoods. Here, we used a spatially-explicit stochastic meta-population model of arbitrary spatial resolution to determine the effect of resolution on model-derived epidemic trajectories. We simulated an influenza-like pathogen spreading across theoretical and actual population densities and varied our assumptions about mobility using Latin-Hypercube sampling. Even though, by design, cumulative attack rates were the same for all resolutions and mobilities, peak incidences were different. Clear thresholds existed for all tested populations, such that models with resolutions lower than the threshold substantially overestimated population-wide peak incidence. The effect of resolution was most important in populations which were of lower density and lower mobility. With the expectation of accurate spatial incidence datasets in the near future, our objective was to provide a framework for how to use these data correctly in a spatial meta-population model. Our results suggest that there is a fundamental spatial resolution for any pathogen-population pair. If underlying interactions between pathogens and spatially heterogeneous populations are represented at this resolution or higher, accurate predictions of peak incidence for city-scale epidemics are feasible.

  3. Peak quantification in surface-enhanced laser desorption/ionization by using mixture models

    NARCIS (Netherlands)

    Dijkstra, Martijn; Roelofsen, Han; Vonk, Roel J.; Jansen, Ritsert C.

    2006-01-01

    Surface-enhanced laser desorption/ionization (SELDI) time of flight (TOF) is a mass spectrometry technology for measuring the composition of a sampled protein mixture. A mass spectrum contains peaks corresponding to proteins in the sample. The peak areas are proportional to the measured

  4. CHALLENGES INCURRED IN THE AUDITING OF FAIR VALUE MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    Silviu-Virgil Chiriac

    2016-07-01

    Full Text Available The purpose of the auditors' work is to establish confidence between the producers and users of accounting information. Thus, auditors help protect the interests of different categories of beneficiaries of accounting information when they make economic decisions. The prevalence of fair values in the financial statements as their inherent measurement uncertainty has increased dramatically in recent years and is recognized as representing a significant problem for regulators. In these circumstances we ask which are the difficulties encountered by auditors in auditing fair values, what kinds of deficiencies they find within auditing and whether the complexity of measurements of fair value jeopardizes the ability of auditors to give a highly secure opinion.

  5. Modified automatic R-peak detection algorithm for patients with epilepsy using a portable electrocardiogram recorder.

    Science.gov (United States)

    Jeppesen, J; Beniczky, S; Fuglsang Frederiksen, A; Sidenius, P; Johansen, P

    2017-07-01

    Earlier studies have shown that short term heart rate variability (HRV) analysis of ECG seems promising for detection of epileptic seizures. A precise and accurate automatic R-peak detection algorithm is a necessity in a real-time, continuous measurement of HRV, in a portable ECG device. We used the portable CE marked ePatch® heart monitor to record the ECG of 14 patients, who were enrolled in the videoEEG long term monitoring unit for clinical workup of epilepsy. Recordings of the first 7 patients were used as training set of data for the R-peak detection algorithm and the recordings of the last 7 patients (467.6 recording hours) were used to test the performance of the algorithm. We aimed to modify an existing QRS-detection algorithm to a more precise R-peak detection algorithm to avoid the possible jitter Qand S-peaks can create in the tachogram, which causes error in short-term HRVanalysis. The proposed R-peak detection algorithm showed a high sensitivity (Se = 99.979%) and positive predictive value (P+ = 99.976%), which was comparable with a previously published QRS-detection algorithm for the ePatch® ECG device, when testing the same dataset. The novel R-peak detection algorithm designed to avoid jitter has very high sensitivity and specificity and thus is a suitable tool for a robust, fast, real-time HRV-analysis in patients with epilepsy, creating the possibility for real-time seizure detection for these patients.

  6. Value measurement of nuclear medicine procedures

    International Nuclear Information System (INIS)

    Potchen, E.J.; Harris, G.I.; Schonbein, W.R.; Rashford, N.J.

    1977-01-01

    The difficulty in measuring the benefit component for cost/benefit analysis of diagnostic procedures in medicine is portrayed as a complex issue relating the objective of intent to a classification of types of decisions a physician must make in evaluating a patient's problem. Ultimately, it seems desirable to develop measuring instruments such as attitude measurement tools by which the relative value of alternative diagnostic procedures could be measured in terms of what they contribute to diminishing the patient's personal perception of disease. Even without this idealized objective, it is reasonable to assume that diagnostic tests which do not contain information, defined as a change in the randomness of a state of knowledge, could not be expected to ultimately benefit the patient. Thus diagnostic information should provide a rational direction for the physician to modify the course of the patient's illness. Since information can be measured as a change in randomness of a knowledge state, we can determine the information content of a specific nuclear medicine procedure when faced with an array of diagnostic problems. These measurements remain to be made for clinical nuclear medicine procedures and are currently under study

  7. The Impact of Political Context on the Measurement of Postmaterial Values

    Directory of Open Access Journals (Sweden)

    Bruce Tranter

    2015-06-01

    Full Text Available This research highlights the influence of political context upon the measurement of postmaterial value orientations. Drawing upon a variety of international survey data, Inglehart claims that since World War II a shift has occurred in advanced industrialized nations from material toward postmaterial values. However, cross-sectional data from Australian Election Study surveys collected over more than two decades indicate that atypically for an advanced democracy, Australian value orientations tend toward the materialist pole. Australian Election Study values estimates are also at odds with those from other national social surveys that portray Australia as a far more postmaterialist nation. Regression analysis demonstrates that after controlling for election issues, attitudes toward political leaders, political party identification, and social background, predicted values estimates are substantially more postmaterial than the raw estimates. The findings have international implications as they suggest that measuring values during or soon after election campaigns may affect the measurement of postmaterial value orientations.

  8. Value for money: Defining and measuring 'value' in MoD's acquisition policy of obtaining best value for money

    OpenAIRE

    Weiss, A.

    2006-01-01

    Obtaining value for money is a keystone of UK Ministry of Defence (MoD) acquisition strategy embedded in its Smart Acquisition policy. This thesis examines how best to measure the relative value of competing tender submissions for major projects. There is a comprehensive discussion of a wide range of relevant definitions and over three dozen documents are scrutinised including just some sixteen published by the Government. Commercially available models, algorithms and software are examined as...

  9. How to measure customer value and its relationship with shareholder value in a business-to-business market

    Directory of Open Access Journals (Sweden)

    Gustavo Bermejo

    2010-10-01

    Full Text Available Intangible assets are difficult to measure, but nowadays the value of the shares of firms in the stock exchange market contains a high percentage of intangible capital and customers are one of the main intangible assets which should be evaluated. This paper presents and discusses some tools to measure the value of customers. But first, it is mandatory to define and clarify the relationships among the concepts of Customer Equity (CE, Life Time Value (LTV and Customer Relationship Management (CRM. LTV is the best financial outcome to measure customer value, so the paper reviews the literature on some mathematical models to calculate LTV. We propose an equation for LTV in order to apply it in a business-to-business market, and an analysis of the influence factors involved in it is made, focusing especially in the link between LTV and shareholder value. Finally, we propose as future lines of research, the relational equity approach as the perfect complement to the customer equity analysis and a way to estimate LTV for actual cases of publicly traded firms using published information.

  10. Fair Value Accounting and Measurement through FASB’s Developments

    OpenAIRE

    Bonaci, Carmen Giorgiana; Strouhal, Jiří; Matis, Dumitru

    2009-01-01

    Our research follows the path of fair value as a term and concept, as well as its disclosure, measurement and recognition back from 1953 until our days, and analyzes the regulations issued by United States Accounting Standard setters, through the point of view of the historical events, which led to their appearance. Our study brings its’ contribution to complementing growing literature on the value relevance of fair value, but focuses on the assessment of fair value as a financial reporting s...

  11. Estimating Time-Varying PCB Exposures Using Person-Specific Predictions to Supplement Measured Values: A Comparison of Observed and Predicted Values in Two Cohorts of Norwegian Women

    Science.gov (United States)

    Nøst, Therese Haugdahl; Breivik, Knut; Wania, Frank; Rylander, Charlotta; Odland, Jon Øyvind; Sandanger, Torkjel Manning

    2015-01-01

    Background Studies on the health effects of polychlorinated biphenyls (PCBs) call for an understanding of past and present human exposure. Time-resolved mechanistic models may supplement information on concentrations in individuals obtained from measurements and/or statistical approaches if they can be shown to reproduce empirical data. Objectives Here, we evaluated the capability of one such mechanistic model to reproduce measured PCB concentrations in individual Norwegian women. We also assessed individual life-course concentrations. Methods Concentrations of four PCB congeners in pregnant (n = 310, sampled in 2007–2009) and postmenopausal (n = 244, 2005) women were compared with person-specific predictions obtained using CoZMoMAN, an emission-based environmental fate and human food-chain bioaccumulation model. Person-specific predictions were also made using statistical regression models including dietary and lifestyle variables and concentrations. Results CoZMoMAN accurately reproduced medians and ranges of measured concentrations in the two study groups. Furthermore, rank correlations between measurements and predictions from both CoZMoMAN and regression analyses were strong (Spearman’s r > 0.67). Precision in quartile assignments from predictions was strong overall as evaluated by weighted Cohen’s kappa (> 0.6). Simulations indicated large inter-individual differences in concentrations experienced in the past. Conclusions The mechanistic model reproduced all measurements of PCB concentrations within a factor of 10, and subject ranking and quartile assignments were overall largely consistent, although they were weak within each study group. Contamination histories for individuals predicted by CoZMoMAN revealed variation between study subjects, particularly in the timing of peak concentrations. Mechanistic models can provide individual PCB exposure metrics that could serve as valuable supplements to measurements. Citation Nøst TH, Breivik K, Wania F

  12. IDENTIFICATIONS PEAK HOURS ON INTERSECTIONS SET IN BIELSKO-BIAŁA CITY

    Directory of Open Access Journals (Sweden)

    Marcin KŁOS

    2016-03-01

    Full Text Available Traffic flow in cities is usually examined locally. This method is not effective for through traffic analysis. The paper discusses the problem of determining peak traffic hours taking into account vehicle distributions. Peak hours represent time periods of traffic flow which demand special treatment by traffic control systems. This is particularly important in the case of ITS. High values of traffic flow require relieving actions not only at the junctions but preferably along the transit routes. The north-south transit route in Bielsko-Biała was chosen for analysis. Instead of the usual two distinct peaks it is determined that the traffic flow is characterised by five peaks. This pattern is the result of specific location of the route, which links residential areas, industrial zones and shopping centres besides carrying through traffic. This multi peak graph more accurately models the traffic flow.

  13. Difficulty in obtaining peak expiratory flow measurements in children with acute asthma.

    Science.gov (United States)

    Gorelick, Marc H; Stevens, Molly W; Schultz, Theresa; Scribano, Philip V

    2004-01-01

    To determine the frequency with which children >or=6 years with acute asthma can perform peak expiratory flow rate measurements (PEFR) in an emergency department (ED). Data were obtained from a prospective cohort study of children with acute asthma. All children (age 2-18 years old) treated in an urban pediatric ED for an acute exacerbation during randomly selected days over a 12-month period were prospectively evaluated. According to treatment protocols, PEFR was to be measured in all children age 6 years and older before therapy and after each treatment with inhaled bronchodilators. Registered respiratory therapists obtained PEFR and evaluated whether patients were able to perform the maneuver adequately. Four hundred and fifty-six children, 6 to 18 years old (median 10 years), were enrolled; 291 (64%) had PEFR measured at least once. Of those in whom PEFR was attempted at least once, only 190 (65%) were able to perform adequately. At the start of therapy, 54% (142/262) were able to perform PEFR. Of the 120 who were unable to perform initially, 76 had another attempt at the end of the ED treatment, and 55 (72%) were still unable to perform. A total of 149 patients had attempts at PEFR both at the start and end of treatment, of these, only 71 (48%) provided valid information on both attempts. Patients unable to perform PEFR were younger (mean +/- SD = 8.7 +/- 2.8 years) than those who were able to perform successfully (11.2 +/- 3.2 years) and those with no attempts (10.0 +/- 3.4 years). Children admitted to the hospital were more likely to be unable to perform PEFR (58/126 = 46%) than those discharged from the ED (43/330 = 13%, P < 0.0001). Adequate PEFR measurements are difficult to obtain in children with acute asthma. Treatment and research protocols cannot rely exclusively on PEFR for evaluation of severity.

  14. Measurement of half-value layer in mammography

    CERN Document Server

    Yagi, H; Saruwatari, R; Doi, N; Yamane, E

    2003-01-01

    The half-value layer (HVL) of an X-ray beam for film-screen mammography is considered an important parameter for image quality and patient dose. Thus, HVL must be measured in accordance with The Manual of Accuracy for Mammography printed by the Japanese Society of Radiological Technology. The manual prescribes exactly the geometry of measurement, chamber position of measurement in the field, selection of chamber, and so on. However, the measurement of HVL is difficult in the actual clinical setting. This study examined the results of failure to perform the measurement of HVL in accordance with the manual for measuring HVL in the clinical setting. The investigation indicated that serious problems do not arise when measuring HVL for routine quality control even if the chamber in the field is not always set according to the manual and if a chamber for radiotherapy or diagnosis is used that is not recommended for soft X-ray by the manual. (author)

  15. International Accounting Convergence in the Field of Fair Value Measurement

    Directory of Open Access Journals (Sweden)

    Diana Cozma Ighian

    2015-09-01

    Full Text Available The investors’ desire for high-quality, internationally comparable financial information that is useful for decision-making in increasingly global capital markets imposed an international convergence, the ultimate goal of which is a single set of international accounting standards that companies worldwide would use for both domestic and cross-border financial reporting. The guidance, set out in IFRS 13 Fair Value Measurement and the update to Topic 820 (formerly referred to as SFAS 157, completes a major project of the boards’ joint work to improve IFRSs and US GAAP and to bring about their convergence. This article describes the controversial history of fair value measurement and the main novelties in the field of fair value measurement, arising from the international convergence process.

  16. The use of personal values in living standards measures

    African Journals Online (AJOL)

    2011-08-26

    Aug 26, 2011 ... Values Questionnaire, Living Standards Measure, purchase decision- .... According to Schwartz (1992), scholars in the areas of psychology, anthropology ... The application of the values perspective to the marketing of .... is a fairly complex task involving large data tables, and that some of the LSM groups.

  17. An empirical method for peak-to-total ratio computation of a gamma-ray detector

    International Nuclear Information System (INIS)

    Cesana, A.; Terrani, M.

    1989-01-01

    A simple expression for peak-to-total ratio evaluation of gamma-ray detectors in the energy range 0.3-10 MeV is proposed. The quantities one needs to know for the computation are: Detector dimensions and chemical composition, photon corss sections and an empirical energy dependent function which is valid for all the detector materials considered. This procedure seems able to produce peak-to-total values with an accuracy comparable with the most sophisticated Monte Carlo calculations. It has been tested using experimental peak-to-total values of Ge, NaI, CsI and BGO detectors but it is reasonable to suppose that it is valid for any detector material. (orig.)

  18. Interpretation of the peak areas in gamma-ray spectra that have a large relative uncertainty

    International Nuclear Information System (INIS)

    Korun, M.; Maver Modec, P.; Vodenik, B.

    2012-01-01

    Empirical evidence is provided that the areas of peaks having a relative uncertainty in excess of 30% are overestimated. This systematic influence is of a statistical nature and originates in way the peak-analyzing routine recognizes the small peaks. It is not easy to detect this influence since it is smaller than the peak-area uncertainty. However, the systematic influence can be revealed in repeated measurements under the same experimental conditions, e.g., in background measurements. To evaluate the systematic influence, background measurements were analyzed with the peak-analyzing procedure described by Korun et al. (2008). The magnitude of the influence depends on the relative uncertainty of the peak area and may amount, in the conditions used in the peak analysis, to a factor of 5 at relative uncertainties exceeding 60%. From the measurements, the probability for type-II errors, as a function of the relative uncertainty of the peak area, was extracted. This probability is near zero below an uncertainty of 30% and rises to 90% at uncertainties exceeding 50%. - Highlights: ► A systematic influence affecting small peak areas in gamma-ray spectra is described. ► The influence originates in the peak locating procedure, using a pre-determined sensitivity. ► The predetermined sensitivity makes peak areas with large uncertainties to be overestimated. ► The influence depends on the relative uncertainty of the number of counts in the peak. ► Corrections exceeding a factor of 3 are attained at peak area uncertainties exceeding 60%.

  19. Extreme value prediction of the wave-induced vertical bending moment in large container ships

    DEFF Research Database (Denmark)

    Andersen, Ingrid Marie Vincent; Jensen, Jørgen Juncher

    2015-01-01

    increase the extreme hull girder response significantly. Focus in the present paper is on the influence of the hull girder flexibility on the extreme response amidships, namely the wave-induced vertical bending moment (VBM) in hogging, and the prediction of the extreme value of the same. The analysis...... in the present paper is based on time series of full scale measurements from three large container ships of 8600, 9400 and 14000 TEU. When carrying out the extreme value estimation the peak-over-threshold (POT) method combined with an appropriate extreme value distribution is applied. The choice of a proper...... threshold level as well as the statistical correlation between clustered peaks influence the extreme value prediction and are taken into consideration in the present paper....

  20. Validation of theoretical models through measured pavement response

    DEFF Research Database (Denmark)

    Ullidtz, Per

    1999-01-01

    mechanics was quite different from the measured stress, the peak theoretical value being only half of the measured value.On an instrumented pavement structure in the Danish Road Testing Machine, deflections were measured at the surface of the pavement under FWD loading. Different analytical models were...... then used to derive the elastic parameters of the pavement layeres, that would produce deflections matching the measured deflections. Stresses and strains were then calculated at the position of the gauges and compared to the measured values. It was found that all analytical models would predict the tensile...

  1. How to Use Value-Added Measures Right

    Science.gov (United States)

    Di Carlo, Matthew

    2012-01-01

    Value-added models are a specific type of "growth model," a diverse group of statistical techniques to isolate a teacher's impact on his or her students' testing progress while controlling for other measurable factors, such as student and school characteristics, that are outside that teacher's control. Opponents, including many teachers, argue…

  2. Peaks and Valleys : Experimental Asset Markets With Non-Monotonic Fundamentals

    NARCIS (Netherlands)

    Noussair, C.N.; Powell, O.R.

    2008-01-01

    We report the results of an experiment designed to measure how well asset market prices track fundamentals when the latter experience peaks and troughs. We observe greater price efficiency in markets in which fundamentals rise to a peak and then decline, than in markets in which fundamentals decline

  3. Hurricane Mitch: Peak Discharge for Selected River Reachesin Honduras

    Science.gov (United States)

    Smith, Mark E.; Phillips, Jeffrey V.; Spahr, Norman E.

    2002-01-01

    Hurricane Mitch began as a tropical depression in the Caribbean Sea on 22 October 1998. By 26 October, Mitch had strengthened to a Category 5 storm as defined by the Saffir-Simpson Hurricane Scale (National Climate Data Center, 1999a), and on 27 October was threatening the northern coast of Honduras (fig. 1). After making landfall 2 days later (29 October), the storm drifted south and west across Honduras, wreaking destruction throughout the country before reaching the Guatemalan border on 31 October. According to the National Climate Data Center of the National Oceanic and Atmospheric Administration (National Climate Data Center, 1999b), Hurricane Mitch ranks among the five strongest storms on record in the Atlantic Basin in terms of its sustained winds, barometric pressure, and duration. Hurricane Mitch also was one of the worst Atlantic storms in terms of loss of life and property. The regionwide death toll was estimated to be more than 9,000; thousands of people were reported missing. Economic losses in the region were more than $7.5 billion (U.S. Agency for International Development, 1999). Honduras suffered the most widespread devastation during the storm. More than 5,000 deaths, and economic losses of more than $4 billion, were reported by the Government of Honduras. Honduran officials estimated that Hurricane Mitch destroyed 50 years of economic development. In addition to the human and economic losses, intense flooding and landslides scarred the Honduran landscape - hydrologic and geomorphologic processes throughout the country likely will be affected for many years. As part of the U.S. Government's response to the disaster, the U.S. Geological Survey (USGS) conducted post-flood measurements of peak discharge at 16 river sites throughout Honduras (fig. 2). Such measurements, termed 'indirect' measurements, are used to determine peak flows when direct measurements (using current meters or dye studies, for example) cannot be made. Indirect measurements of

  4. Peak regulation right

    International Nuclear Information System (INIS)

    Gao, Z. |; Ren, Z.; Li, Z.; Zhu, R.

    2005-01-01

    A peak regulation right concept and corresponding transaction mechanism for an electricity market was presented. The market was based on a power pool and independent system operator (ISO) model. Peak regulation right (PRR) was defined as a downward regulation capacity purchase option which allowed PRR owners to buy certain quantities of peak regulation capacity (PRC) at a specific price during a specified period from suppliers. The PRR owner also had the right to decide whether or not they would buy PRC from suppliers. It was the power pool's responsibility to provide competitive and fair peak regulation trading markets to participants. The introduction of PRR allowed for unit capacity regulation. The PRR and PRC were rated by the supplier, and transactions proceeded through a bidding process. PRR suppliers obtained profits by selling PRR and PRC, and obtained downward regulation fees regardless of whether purchases are made. It was concluded that the peak regulation mechanism reduced the total cost of the generating system and increased the social surplus. 6 refs., 1 tab., 3 figs

  5. measurements of distribution coefficients and lipophilicity values

    African Journals Online (AJOL)

    Preferred Customer

    octanol and water, followed by measuring the distribution of the solute in ... Instrumentation and apparatus: HPLC-UV-DAD and HPLC–ESI-MS experiments .... process in the determination of KD and log P values for the HFSLM extracts. ..... Perrin, D.D.; Dempsey, B. Buffers for pH and Metal Ion Control, Chapman and Hall:.

  6. Coupling hydrologic and hydraulic models to take into consideration retention effects on extreme peak discharges in Switzerland

    Science.gov (United States)

    Felder, Guido; Zischg, Andreas; Weingartner, Rolf

    2015-04-01

    Estimating peak discharges with very low probabilities is still accompanied by large uncertainties. Common estimation methods are usually based on extreme value statistics applied to observed time series or to hydrological model outputs. However, such methods assume the system to be stationary and do not specifically consider non-stationary effects. Observed time series may exclude events where peak discharge is damped by retention effects, as this process does not occur until specific thresholds, possibly beyond those of the highest measured event, are exceeded. Hydrological models can be complemented and parameterized with non-linear functions. However, in such cases calibration depends on observed data and non-stationary behaviour is not deterministically calculated. Our study discusses the option of considering retention effects on extreme peak discharges by coupling hydrological and hydraulic models. This possibility is tested by forcing the semi-distributed deterministic hydrological model PREVAH with randomly generated, physically plausible extreme precipitation patterns. The resulting hydrographs are then used to force the hydraulic model BASEMENT-ETH (riverbed in 1D, potential inundation areas in 2D). The procedure ensures that the estimated extreme peak discharge does not exceed the physical limit given by the riverbed capacity and that the dampening effect of inundation processes on peak discharge is considered.

  7. Measuring Nursing Value from the Electronic Health Record.

    Science.gov (United States)

    Welton, John M; Harper, Ellen M

    2016-01-01

    We report the findings of a big data nursing value expert group made up of 14 members of the nursing informatics, leadership, academic and research communities within the United States tasked with 1. Defining nursing value, 2. Developing a common data model and metrics for nursing care value, and 3. Developing nursing business intelligence tools using the nursing value data set. This work is a component of the Big Data and Nursing Knowledge Development conference series sponsored by the University Of Minnesota School Of Nursing. The panel met by conference calls for fourteen 1.5 hour sessions for a total of 21 total hours of interaction from August 2014 through May 2015. Primary deliverables from the bit data expert group were: development and publication of definitions and metrics for nursing value; construction of a common data model to extract key data from electronic health records; and measures of nursing costs and finance to provide a basis for developing nursing business intelligence and analysis systems.

  8. Direct quantum process tomography via measuring sequential weak values of incompatible observables.

    Science.gov (United States)

    Kim, Yosep; Kim, Yong-Su; Lee, Sang-Yun; Han, Sang-Wook; Moon, Sung; Kim, Yoon-Ho; Cho, Young-Wook

    2018-01-15

    The weak value concept has enabled fundamental studies of quantum measurement and, recently, found potential applications in quantum and classical metrology. However, most weak value experiments reported to date do not require quantum mechanical descriptions, as they only exploit the classical wave nature of the physical systems. In this work, we demonstrate measurement of the sequential weak value of two incompatible observables by making use of two-photon quantum interference so that the results can only be explained quantum physically. We then demonstrate that the sequential weak value measurement can be used to perform direct quantum process tomography of a qubit channel. Our work not only demonstrates the quantum nature of weak values but also presents potential new applications of weak values in analyzing quantum channels and operations.

  9. Peak Oil, Peak Coal and Climate Change

    Science.gov (United States)

    Murray, J. W.

    2009-05-01

    Research on future climate change is driven by the family of scenarios developed for the IPCC assessment reports. These scenarios create projections of future energy demand using different story lines consisting of government policies, population projections, and economic models. None of these scenarios consider resources to be limiting. In many of these scenarios oil production is still increasing to 2100. Resource limitation (in a geological sense) is a real possibility that needs more serious consideration. The concept of 'Peak Oil' has been discussed since M. King Hubbert proposed in 1956 that US oil production would peak in 1970. His prediction was accurate. This concept is about production rate not reserves. For many oil producing countries (and all OPEC countries) reserves are closely guarded state secrets and appear to be overstated. Claims that the reserves are 'proven' cannot be independently verified. Hubbert's Linearization Model can be used to predict when half the ultimate oil will be produced and what the ultimate total cumulative production (Qt) will be. US oil production can be used as an example. This conceptual model shows that 90% of the ultimate US oil production (Qt = 225 billion barrels) will have occurred by 2011. This approach can then be used to suggest that total global production will be about 2200 billion barrels and that the half way point will be reached by about 2010. This amount is about 5 to 7 times less than assumed by the IPCC scenarios. The decline of Non-OPEC oil production appears to have started in 2004. Of the OPEC countries, only Saudi Arabia may have spare capacity, but even that is uncertain, because of lack of data transparency. The concept of 'Peak Coal' is more controversial, but even the US National Academy Report in 2007 concluded only a small fraction of previously estimated reserves in the US are actually minable reserves and that US reserves should be reassessed using modern methods. British coal production can be

  10. Peak globalization. Climate change, oil depletion and global trade

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, Fred [Department of Economics, Drew University, Madison, NJ 07940 (United States)

    2009-12-15

    The global trade in goods depends upon reliable, inexpensive transportation of freight along complex and long-distance supply chains. Global warming and peak oil undermine globalization by their effects on both transportation costs and the reliable movement of freight. Countering the current geographic pattern of comparative advantage with higher transportation costs, climate change and peak oil will thus result in peak globalization, after which the volume of exports will decline as measured by ton-miles of freight. Policies designed to mitigate climate change and peak oil are very unlikely to change this result due to their late implementation, contradictory effects and insufficient magnitude. The implication is that supply chains will become shorter for most products and that production of goods will be located closer to where they are consumed. (author)

  11. Peak globalization. Climate change, oil depletion and global trade

    International Nuclear Information System (INIS)

    Curtis, Fred

    2009-01-01

    The global trade in goods depends upon reliable, inexpensive transportation of freight along complex and long-distance supply chains. Global warming and peak oil undermine globalization by their effects on both transportation costs and the reliable movement of freight. Countering the current geographic pattern of comparative advantage with higher transportation costs, climate change and peak oil will thus result in peak globalization, after which the volume of exports will decline as measured by ton-miles of freight. Policies designed to mitigate climate change and peak oil are very unlikely to change this result due to their late implementation, contradictory effects and insufficient magnitude. The implication is that supply chains will become shorter for most products and that production of goods will be located closer to where they are consumed. (author)

  12. Predicting rheological behavior and baking quality of wheat flour using a GlutoPeak test.

    Science.gov (United States)

    Rakita, Slađana; Dokić, Ljubica; Dapčević Hadnađev, Tamara; Hadnađev, Miroslav; Torbica, Aleksandra

    2018-06-01

    The purpose of this research was to gain an insight into the ability of the GlutoPeak instrument to predict flour functionality for bread making, as well as to determine which of the GlutoPeak parameters show the best potential in predicting dough rheological behavior and baking performance. Obtained results showed that GlutoPeak parameters correlated better with the indices of extensional rheological tests which consider constant dough hydration than with those which were performed at constant dough consistency. The GlutoPeak test showed that it is suitable for discriminating wheat varieties of good quality from those of poor quality, while the most discriminating index was maximum torque (MT). Moreover, MT value of 50 BU and aggregation energy value of 1,300 GPU were set as limits of wheat flour quality. The backward stepwise regression analysis revealed that a high-level prediction of indices which are highly affected by protein content (gluten content, flour water absorption, and dough tenacity) was achieved by using the GlutoPeak indices. Concerning bread quality, a moderate prediction of specific loaf volume and an intense level prediction of breadcrumb textural properties were accomplished by using the GlutoPeak parameters. The presented results indicated that the application of this quick test in wheat transformation chain for the assessment of baking quality would be useful. Baking test is considered as the most reliable method for assessing wheat-baking quality. However, baking test requires trained stuff, time, and large sample amount. These disadvantages have led to a growing demand to develop new rapid tests which would enable prediction of baked product quality with a limited flour size. Therefore, we tested the possibility of using a GlutoPeak tester to predict loaf volume and breadcrumb textural properties. Discrimination of wheat varieties according to quality with a restricted flour amount was also examined. Furthermore, we proposed the limit

  13. Changes in the measurement of fair value : implications for accounting earnings.

    OpenAIRE

    Fargher, N.; Zhang, J.

    2014-01-01

    With the FASB's issue of staff position papers in 2009 and the relaxation of how fair value standards are applied, there has been a change in the practice of how fair value is measured. Since the FASB staff position papers in 2009, fair value measurement by financial institutions has increasingly relied on managerial assumptions. This study examines the impact of this change on the quality of earnings. Consistent with attribute substitution theory that emphasises reliability over relevance, w...

  14. Association between Infancy BMI Peak and Body Composition and Blood Pressure at Age 5–6 Years

    Science.gov (United States)

    Hof, Michel H. P.; Vrijkotte, Tanja G. M.; de Hoog, Marieke L. A.; van Eijsden, Manon; Zwinderman, Aeilko H.

    2013-01-01

    Introduction The development of overweight is often measured with the body mass index (BMI). During childhood the BMI curve has two characteristic points: the adiposity rebound at 6 years and the BMI peak at 9 months of age. In this study, the associations between the BMI peak and body composition measures and blood pressure at age 5–6 years were investigated. Methods Measurements from the Amsterdam Born Children and their Development (ABCD) study were available for this study. Blood pressure (systolic and diastolic) and body composition measures (BMI, waist-to-height ratio, fat percentage) were gathered during a health check at about 6 years of age (n = 2822). All children had multiple BMI measurements between the 0–4 years of age. For boys and girls separately, child-specific BMI peaks were extracted from mixed effect models. Associations between the estimated BMI peak and the health check measurements were analysed with linear models. In addition, we investigated the potential use of the BMI at 9 months as a surrogate measure for the magnitude of the BMI peak. Results After correction for the confounding effect of fetal growth, both timing and magnitude of the BMI peak were significantly and positively associated (pBMI peak showed no direct association with blood pressure at the age 5–6 year, but was mediated by the current BMI. The correlation between the magnitude of the BMI peak and BMI at 9 months was approximately 0.93 and similar associations with the measures at 5–6 years were found. Conclusion The magnitude of the BMI peak was associated with body composition measures at 5–6 years of age. Moreover, the BMI at 9 months could be used as surrogate measure for the magnitude of the BMI peak. PMID:24324605

  15. Peak systolic pressure-volume relationships in man

    International Nuclear Information System (INIS)

    Adachi, Haruhiko; Sugihara, Hiroki; Nakagawa, Hiroaki; Katsume, Hiroshi; Ochiai, Masakazu; Ijichi, Hamao

    1985-01-01

    We determined the relationship between left ventricular (LV) peak systolic pressure (PSP) and end-systolic volume, non-invasively using cuff sphygmomanometry and radionuclide angiocardiography (RNA). Systolic blood pressure (SBP) measured in the arm was substituted for PSP. LV enddiastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were determined by a non-geometric method of gated RNA and recorded in three different hemodynamic states: at rest (basal state), during increased SBP after angiotensin administration (initial dose, 1-2 μg/min) and during decreased SBP after nitrate (sublingual nitroglycerin, 0.3-0.6 mg, or intravenous isosorbide dinitrate, 0.5-1.0 mg/min). The reproducibility of this method, tested in six subjects, proved to be good. Fifty-five subjects were divided into four groups based on EF at rest. The EDV and ESV were increased by angiotensin, and decreased by nitrate in all groups. EF was decreased by angiotensin and increased by nitrate. In contrast, the changes in PSP/ESVI due to these drugs remained in a narrow range in all groups. The regression lines of the PSP/ESVI relationship were almost linear and were steeper in the group with higher EF. Esub(max), the slope of the lines, was 5.75 +- 3.48 mmHg/ml/m 2 in group 1 (EF>50%), 3.16 +- 1.83 mmHg/ml/m 2 in group 2 (EF 49-40%), 2.27 +- 0.86 mmHg/ml/m 2 in group 3 (EF 39-30%) and 0.59 +- 0.50 mmHg/ml/m 2 in group 4 (EF<29%). The theoretical volume at zero pressure (VoI) did not meet in a definite value and was not related to EF at rest. Thus, the left ventricular peak systolic pressure-end-systolic volume relationship can be assessed non-invasively from radionuclide angiocardiography, which can be widely used for the evaluation of ventricular contractility, even in patients with asynergic ventricular contraction for whom echocardiography is unsuitable in measuring ventricular volume. (author)

  16. Size-corrected BMD decreases during peak linear growth: implications for fracture incidence during adolescence.

    Science.gov (United States)

    Faulkner, Robert A; Davison, K Shawn; Bailey, Donald A; Mirwald, Robert L; Baxter-Jones, Adam D G

    2006-12-01

    Peak adolescent fracture incidence at the distal end of the radius coincides with a decline in size-corrected BMD in both boys and girls. Peak gains in bone area preceded peak gains in BMC in a longitudinal sample of boys and girls, supporting the theory that the dissociation between skeletal expansion and skeletal mineralization results in a period of relative bone weakness. The high incidence of fracture in adolescence may be related to a period of relative skeletal fragility resulting from dissociation between bone expansion and bone mineralization during the growing years. The aim of this study was to examine the relationship between changes in size-corrected BMD (BMDsc) and peak distal radius fracture incidence in boys and girls. Subjects were 41 boys and 46 girls measured annually (DXA; Hologic 2000) over the adolescent growth period and again in young adulthood. Ages of peak height velocity (PHV), peak BMC velocity (PBMCV), and peak bone area (BA) velocity (PBAV) were determined for each child. To control for maturational differences, subjects were aligned on PHV. BMDsc was calculated by first regressing the natural logarithms of BMC and BA. The power coefficient (pc) values from this analysis were used as follows: BMDsc = BMC/BA(pc). BMDsc decreased significantly before the age of PHV and then increased until 4 years after PHV. The peak rates in radial fractures (reported from previous work) in both boys and girls coincided with the age of negative velocity in BMDsc; the age of peak BA velocity (PBAV) preceded the age of peak BMC velocity (PBMCV) by 0.5 years in both boys and girls. There is a clear dissociation between PBMCV and PBAV in boys and girls. BMDsc declines before age of PHV before rebounding after PHV. The timing of these events coincides directly with reported fracture rates of the distal end of the radius. Thus, the results support the theory that there is a period of relative skeletal weakness during the adolescent growth period caused, in

  17. Theory of “Weak Value" and Quantum Mechanical Measurements

    OpenAIRE

    Shikano, Yutaka

    2012-01-01

    Comment: to be published from "Measurements in Quantum Mechanics", edited by M. R. Pahlavani (InTech, 2012) Chapter 4 page 75. Yutaka Shikano (2012). ISBN: 978-953-51-0058-4 Available from: http://www.intechopen.com/articles/show/title/theory-of-weak-value-and-quantum-mechanical-measurement

  18. Bayesian statistical evaluation of peak area measurements in gamma spectrometry

    International Nuclear Information System (INIS)

    Silva, L.; Turkman, A.; Paulino, C.D.

    2010-01-01

    We analyze results from determinations of peak areas for a radioactive source containing several radionuclides. The statistical analysis was performed using Bayesian methods based on the usual Poisson model for observed counts. This model does not appear to be a very good assumption for the counting system under investigation, even though it is not questioned as a whole by the inferential procedures adopted. We conclude that, in order to avoid incorrect inferences on relevant quantities, one must proceed to a further study that allows us to include missing influence parameters and to select a model explaining the observed data much better.

  19. A beam-synchronous gated peak-detector for the LHC beam observation system

    CERN Document Server

    Levens, T E; Wehrle, U

    2013-01-01

    Measurements of the bunch peak amplitude using the longitudinal wideband wall-current monitor are a vital tool used in the Large Hadron Collider (LHC) beam observation system. These peak-detected measurements can be used to diagnose bunch shape oscillations, for example coherent quadrupole oscillations, that occur at injection and during beam manipulations. Peak-detected Schottky diagnostics can also be used to obtain the synchrotron frequency distribution and other parameters from a bunched beam under stable conditions. For the LHC a beam-synchronous gated peak detector has been developed to allow individual bunches to be monitored without the influence of other bunches circulating in the machine. The requirement for the observation of both low intensity pilot bunches and high intensity bunches for physics requires a detector front-end with a high bandwidth and a large dynamic range while the usage for Schottky measurements requires low noise electronics. This paper will present the design of this detector s...

  20. Transcutaneous oximetry measurements of the leg: comparing different measuring equipment and establishing values in healthy young adults.

    Science.gov (United States)

    Trinks, Tobias P; Blake, Denise F; Young, Derelle A; Thistlethwaite, Ken; Vangaveti, Venkat N

    2017-06-01

    Transcutaneous oximetry measurement (TCOM) is a non-invasive method of determining oxygen tension at the skin level using heated electrodes. To compare TCOM values generated by different machines and to establish lower limb TCOM values in a cohort of healthy individuals younger than 40 years of age. Sixteen healthy, non-smoking volunteers aged 18 to 39 years were recruited. TCOM was obtained at six locations on the lower leg and foot using three different Radiometer machines. Measurements were taken with subjects lying supine, breathing air. Except for one sensor site, there were no statistical differences in measurements obtained by the different TCOM machines. There was no statistical difference in measurements comparing left and right legs. Room air TCOM values for the different lower leg sites were (mean (SD) in mmHg): lateral leg 61.5 (9.2); lateral ankle 61.1 (9.7); medial ankle 59.1 (10.8); foot, first and second toe 63.4 (10.6); foot, fifth toe 59.9 (13.2) and plantar foot 74.1 (8.8). The overall mean TCOM value for the lower limb was 61 (10.8; 95% confidence intervals 60.05-62.0) mmHg. Lower-leg TCOM measurements using different Radiometer TCOM machines were comparable. Hypoxia has been defined as lower-leg TCOM values of less than 40 mmHg in non-diabetic patients and this is supported by our measurements. The majority (96.9%) of the lower leg TCOM values in healthy young adults are above the hypoxic threshold.

  1. Symmetricity analysis of time to peak parameter of indocyanine green dynamics

    Science.gov (United States)

    An, Yuri; Lee, Jungsul; Choi, Chulhee

    2013-03-01

    We have previously discovered that near-infrared optical imaging of indocyanine green (ICG) signal and analyzing its dynamics can be applied for measurement of blood perfusion rate and detection of Raynaud's phenomenon (RP). Especially, RP is closely associated with abnormal vasomotor responses and can progress to tissue necrosis due to excessively sustained vasoconstriction. Therefore, early detecting of RP is one of important implication to prevent tissue damage from peripheral vascular disorders. In the present study, we propose new analysis and scoring method of symmetricity of Tmax value of left and right extremities. Moreover, this symmetricity analysis can give further information about microvascular insufficiency. For validation of the proposed method, we tested whether the segmental and paired analysis of Tmax value (time-to-peak) of ICG dynamics can be used for sensitive diagnosis of microvascular abnormalities which cannot be detected by conventional methods. From the near-infrared images of diabetes mellitus patients with vascular complications, the trend of asymmetry in Tmax value was observed. We assumed that decreasing local blood perfusion by autonomic nerve dysfunction causes the asymmetric Tmax value of right and left feet. These results collectively indicate that the proposed method can be used as a useful diagnostic tool for RP or other microvascular disorders.

  2. Engineering related neutron diffraction measurements probing strains, texture and microstructure

    Energy Technology Data Exchange (ETDEWEB)

    Clausen, Bjorn [Los Alamos National Laboratory; Brown, Donald W [Los Alamos National Laboratory; Tome, Carlos N [Los Alamos National Laboratory; Balogh, Levente [Los Alamos National Laboratory; Vogel, Sven C [Los Alamos National Laboratory

    2010-01-01

    Neutron diffraction has been used for engineering applications for nearly three decades. The basis of the technique is powder diffraction following Bragg's Law. From the measured diffraction patterns information about internal, or residual, strain can be deduced from the peak positions, texture information can be extracted from the peak intensities, and finally the peak widths can provide information about the microstructure, e.g. dislocation densities and grain sizes. The strains are measured directly from changes in lattice parameters, however, in many cases it is non-trivial to determine macroscopic values of stress or strain from the measured data. The effects of intergranular strains must be considered, and combining the neutron diffraction measurements with polycrystal deformation modeling has proven invaluable in determining the overall stress and strain values of interest in designing and dimensioning engineering components. Furthelmore, the combined use of measurements and modeling has provided a tool for elucidating basic material properties, such as critical resolved shear stresses for the active deformation modes and their evolution as a function of applied deformation.

  3. Make peak flow a habit

    Science.gov (United States)

    Asthma - make peak flow a habit; Reactive airway disease - peak flow; Bronchial asthma - peak flow ... 2014:chap 55. National Asthma Education and Prevention Program website. How to use a peak flow meter. ...

  4. Peak potential meter applied to X-ray tubes in mammal radiography systems

    International Nuclear Information System (INIS)

    Schiabel, Homero; Frere, Annie F.; Andreeta, Jose P.

    1989-01-01

    It is of a great importance to identify accurately the real peak potential (or simply, KVp) applied to a X-ray tube purposed to medical diagnosis, since it defines the beam energetic quality in terms of photons penetration power. Mainly in mammographic systems. it is of fundamental relevance the KVp accurate measurement because the soft tissues involved in this kind of examination provides different absorption - and, hence, clear contrast on mammographic film - just in a very restrict energetic range. Thus a device to measure KVp with adequate accuracy in mammographic units, using the basic principles of scintillation detection, was developed. This system is therefore composed of a NaI(Tl) crystal which is a X-ray sensor - replacing radiographic films which usually are a source of errors in these measurements - , a photo multiplier tube and changed into amplified electric pulses. Finally the electronic circuit, after adequate pulses treatment, shows instantaneously the actual KVp value in the test on displays. (author)

  5. Peak groundwater depletion in the High Plains Aquifer, projections from 1930 to 2110

    Science.gov (United States)

    Peak groundwater depletion from overtapping aquifers beyond recharge rates occurs as the depletion rate increases until a peak occurs followed by a decreasing trend as pumping equilibrates towards available recharge. The logistic equation of Hubbert’s study of peak oil is used to project measurement...

  6. Measurement of δ13C values of soil amino acids by GC-C-IRMS using trimethylsilylation: a critical assessment.

    Science.gov (United States)

    Rubino, Mauro; Milin, Sylvie; D'Onofrio, Antonio; Signoret, Patrick; Hatté, Christine; Balesdent, Jérôme

    2014-01-01

    In this study, we evaluated trimethylsilyl (TMS) derivatives as derivatization reagents for the compound-specific stable carbon isotope analysis of soil amino acids by gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS). We used non-proteinogenic amino acids to show that the extraction-derivatization-analysis procedure provides a reliable method to measure δ(13)C values of amino acids extracted from soil. However, we found a number of drawbacks that significantly increase the final total uncertainty. These include the following: production of multiple peaks for each amino acid, identified as di-, tri- and tetra-TMS derivatives; a number of TMS-carbon (TMS-C) atoms added lower than the stoichiometric one, possibly due to incomplete combustion; different TMS-C δ(13)C for di-, tri- and tetra-TMS derivatives. For soil samples, only four amino acids (leucine, valine, threonine and serine) provide reliable δ(13)C values with a total average uncertainty of 1.3 ‰. We conclude that trimethylsilyl derivatives are only suitable for determining the (13)C incorporation in amino acids within experiments using (13)C-labelled tracers but cannot be applied for amino acids with natural carbon isotope abundance until the drawbacks described here are overcome and the measured total uncertainty significantly decreased.

  7. Computation of distribution of minimum resolution for log-normal distribution of chromatographic peak heights.

    Science.gov (United States)

    Davis, Joe M

    2011-10-28

    General equations are derived for the distribution of minimum resolution between two chromatographic peaks, when peak heights in a multi-component chromatogram follow a continuous statistical distribution. The derivation draws on published theory by relating the area under the distribution of minimum resolution to the area under the distribution of the ratio of peak heights, which in turn is derived from the peak-height distribution. Two procedures are proposed for the equations' numerical solution. The procedures are applied to the log-normal distribution, which recently was reported to describe the distribution of component concentrations in three complex natural mixtures. For published statistical parameters of these mixtures, the distribution of minimum resolution is similar to that for the commonly assumed exponential distribution of peak heights used in statistical-overlap theory. However, these two distributions of minimum resolution can differ markedly, depending on the scale parameter of the log-normal distribution. Theory for the computation of the distribution of minimum resolution is extended to other cases of interest. With the log-normal distribution of peak heights as an example, the distribution of minimum resolution is computed when small peaks are lost due to noise or detection limits, and when the height of at least one peak is less than an upper limit. The distribution of minimum resolution shifts slightly to lower resolution values in the first case and to markedly larger resolution values in the second one. The theory and numerical procedure are confirmed by Monte Carlo simulation. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. New measurements of W-values for protons and alpha particles

    International Nuclear Information System (INIS)

    Giesen, U.; Beck, J.

    2014-01-01

    The increasing importance of ion beams in cancer therapy and the lack of experimental data for W-values for protons and heavy ions in air require new measurements. A new experimental set-up was developed at PTB and consistent measurements of W-values in argon, nitrogen and air for protons and alpha particles with energies from 0.7 to 3.5 MeV u -1 at PTB, and for carbon ions between 3.6 and 7.0 MeV u -1 at GSI were carried out. This publication concentrates on the measurements with protons and alpha particles at PTB. The experimental methods and the determination of corrections for recombination effects, beam-induced background radiation and additional effects are presented. W-values in argon, nitrogen and air were measured for protons with energies of 1-3 MeV and for alpha particles with energies of 2.7-14 MeV. The energies of the primary particle beam were corrected for energy losses in the gold and Mylar foils, as well as for the kinematic energy loss due to scattering by 45 deg.. Beam-induced radiation backgrounds as well as recombination effects were determined and corrected for. The present results are summarised in Figure 2 for all three gases. The solid lines through the data points for each gas indicate an average W-value for that gas. The higher values for 2.7-MeV alpha particles agree with the trend in previous data towards lower energies. They are excluded from the averages. The relative standard uncertainties of the individual data points range from 1.3 to 3 %. The weighted averages over all energies are W(Ar) = 25.7 eV, W(N 2 ) = 35.6 eV and W(Air) = 34.2 eV. The averages serve as a first comparison and the lines on the plot are to guide the eye and are not meant to imply constant W-values for all energies and particles. The W-values for protons and alpha particles in argon and nitrogen have smaller uncertainties and are lower than the suggested values, but they are still in agreement within the uncertainties. For alpha particles with energies of 12

  9. The Effect of Lifting Speed on Cumulative and Peak Biomechanical Loading for Symmetric Lifting Tasks

    Directory of Open Access Journals (Sweden)

    Kasey O. Greenland

    2013-06-01

    Conclusion: Based on peak values, BCF is highest for fast speeds, but the BCF cumulative loading is highest for slow speeds, with the largest difference between fast and slow lifts. This may imply that a slow lifting speed is at least as hazardous as a fast lifting speed. It is important to consider the duration of lift when determining risks for back and shoulder injuries due to lifting and that peak values alone are likely not sufficient.

  10. ESCADT: a FORTRAN code for computing the positions and areas of x-ray photoelectron spectral peaks

    International Nuclear Information System (INIS)

    Cox, L.E.

    1979-09-01

    Program ESCADT uses least-squares-derived convoluting numbers to smooth and differentiate x-ray photoelectron spectra. Peak maxima are located by finding zero crossings of the first derivative and refined using a cubic polynomial fitting procedure. Background points are located using the product of the absolute value of the first derivative and the smoothed ordinate value. Peak areas, using both linear and scattered electron backgrounds, are computed. Spectra are corrected for changes in instrument sensitivity and energy calibration with gold-standard data retrieved from a disk file. Five determinations of the gold 4f peak positions yielded standard deviations of 0.011 and 0.031 eV for the 4f/sub 7/2/ and 4f/sub 5/2/ peaks, respectively. The relative standard deviation for the computed areas was 0.85%

  11. An automated A-value measurement tool for accurate cochlear duct length estimation.

    Science.gov (United States)

    Iyaniwura, John E; Elfarnawany, Mai; Ladak, Hanif M; Agrawal, Sumit K

    2018-01-22

    There has been renewed interest in the cochlear duct length (CDL) for preoperative cochlear implant electrode selection and postoperative generation of patient-specific frequency maps. The CDL can be estimated by measuring the A-value, which is defined as the length between the round window and the furthest point on the basal turn. Unfortunately, there is significant intra- and inter-observer variability when these measurements are made clinically. The objective of this study was to develop an automated A-value measurement algorithm to improve accuracy and eliminate observer variability. Clinical and micro-CT images of 20 cadaveric cochleae specimens were acquired. The micro-CT of one sample was chosen as the atlas, and A-value fiducials were placed onto that image. Image registration (rigid affine and non-rigid B-spline) was applied between the atlas and the 19 remaining clinical CT images. The registration transform was applied to the A-value fiducials, and the A-value was then automatically calculated for each specimen. High resolution micro-CT images of the same 19 specimens were used to measure the gold standard A-values for comparison against the manual and automated methods. The registration algorithm had excellent qualitative overlap between the atlas and target images. The automated method eliminated the observer variability and the systematic underestimation by experts. Manual measurement of the A-value on clinical CT had a mean error of 9.5 ± 4.3% compared to micro-CT, and this improved to an error of 2.7 ± 2.1% using the automated algorithm. Both the automated and manual methods correlated significantly with the gold standard micro-CT A-values (r = 0.70, p value measurement tool using atlas-based registration methods was successfully developed and validated. The automated method eliminated the observer variability and improved accuracy as compared to manual measurements by experts. This open-source tool has the potential to benefit

  12. Linking Quality and Spending to Measure Value for People with Serious Illness

    Science.gov (United States)

    Rodgers, Phillip E.

    2018-01-01

    Abstract Background: Healthcare payment is rapidly evolving to reward value by measuring and paying for quality and spending performance. Rewarding value for the care of seriously ill patients presents unique challenges. Objective: To evaluate the state of current efforts to measure and reward value for the care of seriously ill patients. Design: We performed a PubMed search of articles related to (1) measures of spending for people with serious illness and (2) linking spending and quality measures and rewarding performance for the care of people with serious illness. We limited our search to U.S.-based studies published in English between January 1, 1960, and March 31, 2017. We supplemented this search by identifying public programs and other known initiatives that linked quality and spending for the seriously ill and extracted key program elements. Results: Our search related to linking spending and quality measures and rewarding performance for the care of people with serious illness yielded 277 articles. We identified three current public programs that currently link measures of quality and spending—or are likely to within the next few years—the Oncology Care Model; the Comprehensive End-Stage Renal Disease Model; and Home Health Value-Based Purchasing. Models that link quality and spending consist of four core components: (1) measuring quality, (2) measuring spending, (3) the payment adjustment model, and (4) the linking/incentive model. We found that current efforts to reward value for seriously ill patients are targeted for specific patient populations, do not broadly encourage the use of palliative care, and have not closely aligned quality and spending measures related to palliative care. Conclusions: We develop recommendations for policymakers and stakeholders about how measures of spending and quality can be balanced in value-based payment programs. PMID:29091529

  13. Peak tree: a new tool for multiscale hierarchical representation and peak detection of mass spectrometry data.

    Science.gov (United States)

    Zhang, Peng; Li, Houqiang; Wang, Honghui; Wong, Stephen T C; Zhou, Xiaobo

    2011-01-01

    Peak detection is one of the most important steps in mass spectrometry (MS) analysis. However, the detection result is greatly affected by severe spectrum variations. Unfortunately, most current peak detection methods are neither flexible enough to revise false detection results nor robust enough to resist spectrum variations. To improve flexibility, we introduce peak tree to represent the peak information in MS spectra. Each tree node is a peak judgment on a range of scales, and each tree decomposition, as a set of nodes, is a candidate peak detection result. To improve robustness, we combine peak detection and common peak alignment into a closed-loop framework, which finds the optimal decomposition via both peak intensity and common peak information. The common peak information is derived and loopily refined from the density clustering of the latest peak detection result. Finally, we present an improved ant colony optimization biomarker selection method to build a whole MS analysis system. Experiment shows that our peak detection method can better resist spectrum variations and provide higher sensitivity and lower false detection rates than conventional methods. The benefits from our peak-tree-based system for MS disease analysis are also proved on real SELDI data.

  14. In situ measurements of X-ray peak profile asymmetry from individual grains

    DEFF Research Database (Denmark)

    Wejdemann, Christian; Lienert, U.; Pantleon, Wolfgang

    2010-01-01

    Two copper samples, pre-deformed in tension to 5% plastic strain, are subjected to an in situ tensile deformation of 1% plastic strain while X-ray peak profiles from individual bulk grains are obtained. One sample is oriented with the in situ tensile axis parallel to the pre-deformation axis...

  15. Peak effect in surface resistance at microwave frequencies in Dy ...

    Indian Academy of Sciences (India)

    In the measurements at both frequencies the induced microwave current was always less than the critical current of the films. The reason for observation of this peak effect in these films has been explained in our earlier publication [5]. Comparing figures 1 and 2, it is observed that the peaks in sample S1 are broader and.

  16. The Value of Improved Measurements in a Pig Slaughterhouse

    DEFF Research Database (Denmark)

    Kjærsgaard, Niels Christian

    The pig industry is an essential and important part of Danish economy with an export value in 2006 of more than DKK 28 billions [Danish Meat Association (2007)]. The competition is hard, and potential new competitors from low cost countries can be expected to enter the traditional Danish export...... markets. Therefore it is more important than ever to optimize all aspects of Danish pig production, slaughtering processes and delivery. This paper concerns the aspects of optimization at the slaughterhouses regarding estimation of the value of improved measurements. The slaughterhouse industry differs...... investments are expected to improve the quality of the measurements further. This paper concerns the use of Operations Research to solve a practical problem, which is of major importance for the industry, namely to improve the estimation of the economic effects of improved measurements. The benefit...

  17. Positive-operator-valued measure optimization of classical correlations

    NARCIS (Netherlands)

    Hamieh, S; Kobes, R; Zaraket, H

    We study the problem of optimization over positive-operator-valued measures to extract classical correlation in a bipartite quantum system. The proposed method is applied to binary states only. Moreover, to illustrate this method, an explicit example is studied in detail.

  18. O2 uptake kinetics during exercise at peak O2 uptake.

    Science.gov (United States)

    Scheuermann, Barry W; Barstow, Thomas J

    2003-11-01

    Compared with moderate- and heavy-intensity exercise, the adjustment of O2 uptake (VO2) to exercise intensities that elicit peak VO2 has received relatively little attention. This study examined the VO2 response of 21 young, healthy subjects (25 +/- 6 yr; mean +/- SD) during cycle ergometer exercise to step transitions in work rate (WR) corresponding to 90, 100, and 110% of the peak WR achieved during a preliminary ramp protocol (15-30 W/min). Gas exchange was measured breath by breath and interpolated to 1-s values. VO2 kinetics were determined by use of a two- or three-component exponential model to isolate the time constant (tau2) as representative of VO2 kinetics and the amplitude (Amp) of the primary fast component independent of the appearance of any VO2 slow component. No difference in VO2 kinetics was observed between WRs (tau90 = 24.7 +/- 9.0; tau100 = 22.8 +/- 6.7; tau110 = 21.5 +/- 9.2 s, where subscripts denote percent of peak WR; P > 0.05); nor in a subgroup of eight subjects was tau2 different from the value for moderate-intensity (exercise (tau2 = 25 +/- 12 s, P > 0.05). As expected, the Amp increased with increasing WRs (Amp90 = 2,089 +/- 548; Amp100 = 2,165 +/- 517; Amp110 = 2,225 +/- 559 ml/min; Amp90 vs. Amp110, P exercise, the gain of the Vo2 response (as deltaVO2/DeltaWR) is reduced for exercise transitions in the severe-intensity domain, but the approach to this gain is well described by a common time constant that is invariant across work intensities. The lower deltaVO2/deltaWR may be due to an insufficient adjustment of the cardiovascular and/or pulmonary systems that determine O2 delivery to the exercising muscles or due to recruitment of motor units with lower oxidative capacity, after the onset of exercise in the severe-intensity domain.

  19. Conjectures Regarding the Adoption of Fair Value Measurements in Brazil

    Directory of Open Access Journals (Sweden)

    Fernando Dal-Ri Murcia

    2008-01-01

    Full Text Available The issue of relevance versus reliability has always been a debate in accounting. Far from being a consensus among the community, the adoption of fair value measurements is intended to present a more realistic view of an entity¿s financial position. However, it could also cause a loss of credibility due to the subjectivity inherent in the valuation process. Wishing to make a contribution to the existing literature on this issue, this paper presents a discussion about the adoption of fair value measurements in Brazil. First, we present a brief examination of asset and liability valuation using the accounting theory as a framework. Following, we conduct a review of the International Accounting Standards Board (IASB and the Financial Accounting Standards Board (FASB standards regarding fair value measurements. Empirical studies addressing fair value are also reviewed. Finally, a discussion about its implementation is presented, aiming to take into account the specificities of the Brazilian Market. This paper intends to contribute to the construction of academic knowledge in accounting by debating an issue which is a real problem for organizations, and yet incipient in the national literature.

  20. Detection of novel visible-light region absorbance peaks in the urine after alkalization in patients with alkaptonuria.

    Science.gov (United States)

    Tokuhara, Yasunori; Shukuya, Kenichi; Tanaka, Masami; Mouri, Mariko; Ohkawa, Ryunosuke; Fujishiro, Midori; Takahashi, Tomoo; Okubo, Shigeo; Yokota, Hiromitsu; Kurano, Makoto; Ikeda, Hitoshi; Yamaguchi, Seiji; Inagaki, Shinobu; Ishige-Wada, Mika; Usui, Hiromi; Yatomi, Yutaka; Shimosawa, Tatsuo

    2014-01-01

    Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA) in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2) and compared them with those of urine specimens obtained from healthy volunteers (n = 5) and patients with phenylketonuria (n = 3), and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added) as compared with those in weakly alkaline samples (NH4OH-added). In addition, the peaks disappeared following the addition of ascorbic acid to the samples. We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the diagnosis of alkaptonuria.

  1. Detection of novel visible-light region absorbance peaks in the urine after alkalization in patients with alkaptonuria.

    Directory of Open Access Journals (Sweden)

    Yasunori Tokuhara

    Full Text Available BACKGROUND: Alkaptonuria, caused by a deficiency of homogentisate 1,2-dioxygenase, results in the accumulation of homogentisic acid (2,5-dihydroxyphenylacetic acid, HGA in the urine. Alkaptonuria is suspected when the urine changes color after it is left to stand at room temperature for several hours to days; oxidation of homogentisic acid to benzoquinone acetic acid underlies this color change, which is accelerated by the addition of alkali. In an attempt to develop a facile screening test for alkaptonuria, we added alkali to urine samples obtained from patients with alkaptonuria and measured the absorbance spectra in the visible light region. METHODS: We evaluated the characteristics of the absorption spectra of urine samples obtained from patients with alkaptonuria (n = 2 and compared them with those of urine specimens obtained from healthy volunteers (n = 5 and patients with phenylketonuria (n = 3, and also of synthetic homogentisic acid solution after alkalization. Alkalization of the urine samples and HGA solution was carried out by the addition of NaOH, KOH or NH4OH. The sample solutions were incubated at room temperature for 1 min, followed by measurement of the absorption spectra. RESULTS: Addition of alkali to alkaptonuric urine yielded characteristic absorption peaks at 406 nm and 430 nm; an identical result was obtained from HGA solution after alkalization. The absorbance values at both 406 nm and 430 nm increased in a time-dependent manner. In addition, the absorbance values at these peaks were greater in strongly alkaline samples (NaOH- KOH-added as compared with those in weakly alkaline samples (NH4OH-added. In addition, the peaks disappeared following the addition of ascorbic acid to the samples. CONCLUSIONS: We found two characteristic peaks at 406 nm and 430 nm in both alkaptonuric urine and HGA solution after alkalization. This new quick and easy method may pave the way for the development of an easy method for the

  2. Seismic Hazard Analysis based on Earthquake Vulnerability and Peak Ground Acceleration using Microseismic Method at Universitas Negeri Semarang

    Science.gov (United States)

    Sulistiawan, H.; Supriyadi; Yulianti, I.

    2017-02-01

    Microseismic is a harmonic vibration of land that occurs continuously at a low frequency. The characteristics of microseismic represents the characteristics of the soil layer based on the value of its natural frequency. This paper presents the analysis of seismic hazard at Universitas Negeri Semarang using microseismic method. The data acquisition was done at 20 points with distance between points 300 m by using three component’s seismometer. The data was processed using Horizontal to Vertical Spectral Ratio (HVSR) method to obtain the natural frequency and amplification value. The value of the natural frequency and amplification used to determine the value of the earthquake vulnerability and peak ground acceleration (PGA). The result shows then the earthquake vulnerability value range from 0.2 to 7.5, while the value of the average peak ground acceleration (PGA) is in the range 10-24 gal. Therefore, the average peak ground acceleration equal to earthquake intensity IV MMI scale.

  3. Reference values of inspiratory spirometry for Finnish adults.

    Science.gov (United States)

    Kainu, Annette; Timonen, Kirsi L; Vanninen, Esko; Sovijärvi, Anssi R

    2018-03-07

    Inspiratory spirometry is used in evaluation of upper airway disorders e.g. fixed or variable obstruction. There are, however, very few published data on normal values for inspiratory spirometry. The main aim of this study was to produce reference values for inspiratory spirometry for healthy Finnish adults. Inspiratory spirometry was preplanned to a sample of the Finnish spirometry reference values sample. Data was successfully retrieved from 368 healthy nonsmoking adults (132 males) between 19 and 83 years of age. Reference equations were produced for forced inspiratory vital capacity (FIVC), forced inspiratory volume in one second (FIV1), FIV1/FIVC, peak inspiratory flow (PIF) and the ratios of FIV1/forced expiratory volume in one second and PIF/peak expiratory flow. The present values were compared to PIF values from previously used Finnish study of Viljanen et al. (1982) reference values and Norwegian values for FIV1, FIVC and FIV1/FIVC presented by Gulsvik et al. (2001). The predicted values from the Gulsvik et al. (2001), provided a good fit for FIVC, but smaller values for FIV1 with mean 108.3 and 109.1% of predicted values for males and females, respectively. PIF values were 87.4 and 91.2% of Viljanen et al. (1982) predicted values in males and females, respectively. Differences in measurement methods and selection of results may contribute to the observed differences. Inspiratory spirometry is technically more demanding and needs repeatability criteria to improve validity. New reference values are suggested to clinical use in Finland when assessing inspiratory spirometry. Utility of inspiratory to expiratory values indices in assessment of airway collapse need further study.

  4. Method and apparatus for clockless analog-to-digital conversion and peak detection

    Science.gov (United States)

    DeGeronimo, Gianluigi

    2007-03-06

    An apparatus and method for analog-to-digital conversion and peak detection includes at least one stage, which includes a first switch, second switch, current source or capacitor, and discriminator. The discriminator changes state in response to a current or charge associated with the input signal exceeding a threshold, thereby indicating whether the current or charge associated with the input signal is greater than the threshold. The input signal includes a peak or a charge, and the converter includes a peak or charge detect mode in which a state of the switch is retained in response to a decrease in the current or charge associated with the input signal. The state of the switch represents at least a portion of a value of the peak or of the charge.

  5. Peak bone mass density among residents of metro Manila: A preliminary report

    International Nuclear Information System (INIS)

    Lim-Abrahan, M.A.; Guanzon, L.V.; Guzman, A.M. de; Villaruel, C.M.; Santos, F.

    1998-01-01

    Study Objective: To determine the peak bone mass density among residents of Metro Manila using dual X-ray absorptiometry (DEXA). Design: Cross-sectional study. Setting: Philippine General Hospital, a university based tertiary care hospital, and St. Luke's Medical Center, a private tertiary care center. Subjects: Forty five (45) healthy subjects aged 15-50 years old, all current residents of Metro Manila, were randomly chosen from among hospital companions were included in the study. There were 23 females and 22 males, with 3 to 4 subjects for each age range of 5. Methods: Bone mass density measurements on the lumbar spine and the femur using dual X-ray absorptiometry (DPXL Lunar) were taken. The values were also age-matched and matched with that of a young adult based on programmed Caucasian norm provided by Lunar Co. The values were then scattered against age for each sex. Ten (10) cc of blood was also extracted from the patients, with the 5 cc of blood separated for future studies. Parathormone assay and biochemistry examinations were also done. Patents were also interviewed as to their lifestyle, diet, use of contraceptive pill or hormonal replacement treatment, using a Filipino version of the revised questionnaire on the WHO Study on Osteoporosis. Dietary content was estimated using a previous day food recall. Results: The mean weight and height for females were 59.48±16.34 kg and 153.52±5.09 cm respectively, and for males, 58.14±10.06 kg and 162.52±6.75 cm respectively. The mean bone mass density at the L 2 L 4 level for females was 1.12±0.11 g/cm 2 and 0.91±0.11 g/cm 2 at the femur. The highest BMD in both the lumbar spine femoral neck measurements among females was achieved among those aged 30-35 years of age with the lowest BMD occurring between 15-19 and 45-50 years of age in the lumbar spine among female subjects. The highest BMD at the lumbar spine and the femoral neck among males was achieved between the ages 30-35 years of age with the lowest IND

  6. Decreasing fuel cost weight in electric utility business. ; Urged peak measures and management constitution improvement. Denki jigyo no nenryohi weight wa gensho. ; Isogareru peak taisaku to keiei taishitsu kaizen

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    The electric power industry has made stable and economic power supply possible by advancing diversification in power sources and shifting the petroleum supply sources to southern countries and China. The cost constitution of the electric utility business in the fiscal year 1992 was such that the ratio of fuel cost is 15.9% against the total cost amount of 13 trillion 399.3 billion yen. As opposed, the fuel cost percent in the fiscal 1980 was 37.7%. This means that the effect of the fuel cost on the total cost has become smaller even if the fuel cost varies as a result of external factors including fluctuation in foreign exchange rates. Peaks in the power demand have been recorded in day time in high summer when air conditioning demand increases, which have been growing year after year. Expenses to maintain facilities and functions to deal with this demand increase have been increasing. The owned capital ratio in the electric power business was 15.7% in the fiscal 1992, which is by far lower than the average of whole industry of 28%. Execution of measures against the power peaks and improvement of the management constitution are the problems posed on the electric power industry. 4 figs., 1 tab.

  7. The Technical Integration of Remote Sensing and Geographical Information System to Predict the Peak Discharge Which Uses the Characteristic of Physical Environment of Catchments Area In Elo Sub Catchments Area in Central java

    Directory of Open Access Journals (Sweden)

    Sugiharto Budi Santoso

    2004-01-01

    The results of the research show that: (1 the aerial photo of black and white panchromatic on the scale 1:50. 000 is obtained to interpret the slope area and it is not good to interpret the accuracy of the covered arm is about 87% and 77,4 %, (2 the current coeflicient which is accounted hased on the table of Cook method is about 40,36% - deviates 39,94% from the field data; (3 the peak discharge in Elo sub catchments area with rational formula is about 3022,03 m/second, while the peak discharge as the observation result is about 112,675 m/second. Its large of research area causs the time to peak takes a long time, which causes raining intensity increases. The increasing value of raining intensity and the flow coeficient makes the value of peak discharge increases that larger than measured peak discharge.

  8. A model for measuring value for money in professional sports

    Directory of Open Access Journals (Sweden)

    Vlad ROŞCA

    2013-07-01

    Full Text Available Few to almost none sports teams measure the entertainment value they provide to fans in exchange of the money the latter ones spend on admission fees. Scientific literature oversees the issue as well. The aim of this paper is to present a model that can be used for calculating value for money in the context of spectating sports. The research question asks how can value for money be conceptualized and measured for sports marketing purposes? Using financial and sporting variables, the method calculates how much money, on average, a fan had to spend for receiving quality entertainment – defined as won matches – from his favorite team, during the last season of the Romanian first division football championship. The results only partially confirm the research hypothesis, showing that not just price and sporting performances may influence the value delivered to fans, but other factors as well.

  9. Seafloor characterisation using echo peak amplitudes of multibeam hydrosweep system - A preliminary study at Arabian Sea

    Digital Repository Service at National Institute of Oceanography (India)

    Chakraborty, B.; Sudhakar, T.

    In this paper an interface to acquire 59-beams echo peak amplitudes of the Hydrosweep Multibeam system is established. The echo peak amplitude values collected at varying seabed provinces of Arabian sea are presented. The study reveals...

  10. Peak radiated power measurement of the DOE Mark II container tag with integrated ST-676 sensor radio frequency identification device.

    Energy Technology Data Exchange (ETDEWEB)

    Jursich, Mark

    2010-04-01

    The total peak radiated power of the Department of Energy Mark II container tag was measured in the electromagnetic reverberation chamber facility at Sandia National Laboratories. The tag's radio frequency content was also evaluated for possible emissions outside the intentional transmit frequency band. No spurious emissions of any significance were found, and the radiated power conformed to the manufacturer's specifications.

  11. Theoretical basis to measure the impact of short-lasting control of an infectious disease on the epidemic peak

    Directory of Open Access Journals (Sweden)

    Omori Ryosuke

    2011-01-01

    Full Text Available Abstract Background While many pandemic preparedness plans have promoted disease control effort to lower and delay an epidemic peak, analytical methods for determining the required control effort and making statistical inferences have yet to be sought. As a first step to address this issue, we present a theoretical basis on which to assess the impact of an early intervention on the epidemic peak, employing a simple epidemic model. Methods We focus on estimating the impact of an early control effort (e.g. unsuccessful containment, assuming that the transmission rate abruptly increases when control is discontinued. We provide analytical expressions for magnitude and time of the epidemic peak, employing approximate logistic and logarithmic-form solutions for the latter. Empirical influenza data (H1N1-2009 in Japan are analyzed to estimate the effect of the summer holiday period in lowering and delaying the peak in 2009. Results Our model estimates that the epidemic peak of the 2009 pandemic was delayed for 21 days due to summer holiday. Decline in peak appears to be a nonlinear function of control-associated reduction in the reproduction number. Peak delay is shown to critically depend on the fraction of initially immune individuals. Conclusions The proposed modeling approaches offer methodological avenues to assess empirical data and to objectively estimate required control effort to lower and delay an epidemic peak. Analytical findings support a critical need to conduct population-wide serological survey as a prior requirement for estimating the time of peak.

  12. Peak Experience Project

    Science.gov (United States)

    Scott, Daniel G.; Evans, Jessica

    2010-01-01

    This paper emerges from the continued analysis of data collected in a series of international studies concerning Childhood Peak Experiences (CPEs) based on developments in understanding peak experiences in Maslow's hierarchy of needs initiated by Dr Edward Hoffman. Bridging from the series of studies, Canadian researchers explore collected…

  13. Measurement invariance of the Portrait Values Questionnaire across 25 European countries

    DEFF Research Database (Denmark)

    Scholderer, Joachim

    The Portrait Values Questionnaire (PVQ) is tested for cross-cultural validity. Measurement characteristics are compared across representative consumer samples from 25 European countries (total N = 37,592) using multi-group confirmatory factor analysis with structured means. The results suggest....... Hence, most direct comparisons of PVQ raw scores and sample statistics between European countries are valid without correction. Furthermore, it can be concluded that the ten values measured by the PVQ are invariant across European countries in terms of their relative position on the quasi......-circumplex hypothesised by the theory of basic human values....

  14. Oxygen uptake efficiency slope and peak oxygen consumption predict prognosis in children with tetralogy of Fallot.

    Science.gov (United States)

    Tsai, Yun-Jeng; Li, Min-Hui; Tsai, Wan-Jung; Tuan, Sheng-Hui; Liao, Tin-Yun; Lin, Ko-Long

    2016-07-01

    Oxygen uptake efficiency slope (OUES) and peak oxygen consumption (VO2peak) are exercise parameters that can predict cardiac morbidity in patients with numerous heart diseases. But the predictive value in patients with tetralogy of Fallot is still undetermined, especially in children. We evaluated the prognostic value of OUES and VO2peak in children with total repair of tetralogy of Fallot. Retrospective cohort study. Forty tetralogy of Fallot patients younger than 12 years old were recruited. They underwent a cardiopulmonary exercise test during the follow-up period after total repair surgery. The results of the cardiopulmonary exercise test were used to predict the cardiac related hospitalization in the following two years after the test. OUES normalized by body surface area (OUES/BSA) and the percentage of predicted VO2peak appeared to be predictive for two-year cardiac related hospitalization. Receiver operating characteristic curve analysis demonstrated that the best threshold value for OUES/BSA was 1.029 (area under the curve = 0.70, p = 0.03), and for VO2peak was 74% of age prediction (area under the curve = 0.72, p = 0.02). The aforementioned findings were confirmed by Kaplan-Meier plots and log-rank test. OUES/BSA and VO2peak are useful predictors of cardiac-related hospitalization in children with total repair of tetralogy of Fallot. © The European Society of Cardiology 2015.

  15. Centers responsible for the TL peaks of willemite mineral estimated by EPR analysis

    Energy Technology Data Exchange (ETDEWEB)

    Gundu Rao, T.K. [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil); Cano, Nilo F., E-mail: nilo.cano@unifesp.br [Departamento de Ciências do Mar, Universidade Federal de São Paulo, Rua Doutor Carvalho de Mendonça, 144, CEP 11070-102, Santos, SP (Brazil); Silva-Carrera, Betzabel N.; Ferreira, Reinaldo M. [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil); Javier-Ccallata, Henry S., E-mail: henrysjc@gmail.com [Escuela Profesional de Física, Facultad de Ciencias Naturales y Formales, Universidad Nacional de San Agustín (UNSA), Av. Independencia S/N, Arequipa (Peru); Watanabe, Shigueo, E-mail: watanabe@if.usp.br [Instituto de Física, Universidade de São Paulo, Rua do Matão, Travessa R, 187, CEP 05508-090, São Paulo, SP (Brazil)

    2016-09-15

    The mineral willemite (Zn{sub 2}SiO{sub 4}) exhibits five thermoluminescence (TL) peaks approximately at 160, 225, 260, 310 and 400 °C. Electron paramagnetic resonance (EPR) studies were carried out to study the defect centers induced in the mineral by gamma irradiation and also to identify the centers responsible for the TL process. Room temperature EPR spectrum of irradiated mineral is a superposition of at least four distinct centers. One of the centers (center I) with an isotropic g factor 2.0114 is attributable to an intrinsic O{sup −} type center and the center correlates with the TL peak at 160 °C. Center II exhibiting hyperfine lines is also tentatively assigned to an O{sup −} ion and is related to the low temperature TL peak at 160 °C. Center III is characterized by an axially symmetric g-tensor with principal values g{sub ||}=2.0451 and g{sub ⊥}=2.011 and is identified as an O{sub 2}{sup −} ion. This center appears to be related to 160, 225 and 260 °C TL peaks. Center IV with principal g-values g{sub ||}=2.0025 and g{sub ⊥}=2.0088 is attributed to an F{sup +}-type center (singly ionized oxygen vacancy) and is the likely recombination center for TL peaks between 160 and 310 °C.

  16. Escape peak ratios in silicon X-ray charge coupled devices (CCDs)

    International Nuclear Information System (INIS)

    McCarthy, K.J.; Owens, A.; Keay, A.

    1997-01-01

    The intensity of the escape peak from the CCDs developed for the Joint European X-ray Telescope (JET-X) has been investigated over the energy range 2-10 keV. Both measured and calculated escape peak ratios (i.e., the ratio of counts in the escape peak to the sum of the counts in the escape and main peaks) are found to be in excellent agreement for all event sizes (i.e., single pixel events, 1 and 2 pixel events, etc.). Using a Monte Carlo simulation the escape peak ratio has been investigated as a function of pixel size and depletion depth. For completeness, we list the energy dependent parameterised forms for five CCDs used in three major astronomy missions. (orig.)

  17. Measurement of 235U Enrichment Using the Semi-Peak-Ratio Technique with CdZnTe Gamma-Ray Detector

    International Nuclear Information System (INIS)

    Ha, J. H.; Ko, W. I.; Lee, S. Y.; Song, D. Y.; Kim, H. D.; Yang, M. S.

    2001-01-01

    In uranium enrichment plants and nuclear fuel fabrication facilities, exact measurement of fissile isotope enrichment of Uranium is required for material accounting in international safeguards inspection as well as process quality control. The purpose of this study was to develop a simple measurement system which can portably be used at nuclear fuel fabrication plants especially dealing with low enriched uranium. For this purpose, a small size CZT (CdZnTe) detector was used, and the detector performance in low uranium gamma/X-rays energy range was investigated by use of various enriched uranium oxide samples. New enrichment measurement technique and analysis method for low enriched uranium oxide, so-called, 'semi-peak ratio technique' was developed. The newly developed method was considered as an alternative technique for the low enrichment and would be useful to account nuclear material in safeguarding activity at nuclear fuel fabrication facility

  18. Normal values for myocardial deformation within the right heart measured by feature-tracking cardiovascular magnetic resonance imaging.

    Science.gov (United States)

    Liu, Boyang; Dardeer, Ahmed M; Moody, William E; Edwards, Nicola C; Hudsmith, Lucy E; Steeds, Richard P

    2018-02-01

    Reproducible and repeatable assessment of right heart function is vital for monitoring congenital and acquired heart disease. There is increasing evidence for the additional value of myocardial deformation (strain and strain rate) in determining prognosis. This study aims to determine the reproducibility of deformation analyses in the right heart using cardiovascular magnetic resonance feature tracking (FT-CMR); and to establish normal ranges within an adult population. A cohort of 100 healthy subjects containing 10 males and 10 females from each decade of life between the ages of 20 and 70 without known congenital or acquired cardiovascular disease, hypertension, diabetes, dyslipidaemia or renal, hepatic, haematologic and systemic inflammatory disorders underwent FT-CMR assessment of right ventricular (RV) and right atrial (RA) myocardial strain and strain rate. RV longitudinal strain (Ell) was -21.9±3.24% (FW+S Ell) and -24.2±3.59% (FW-Ell). Peak systolic strain rate (S') was -1.45±0.39s -1 (FW+S) and -1.54±0.41s -1 (FW). Early diastolic strain rate (E') was 1.04±0.26s -1 (FW+S) and 1.04±0.33s -1 (FW). Late diastolic strain rate (A') was 0.94±0.33s -1 (FW+S) and 1.08±0.33s -1 (FW). RA peak strain was -21.1±3.76%. The intra- and inter-observer ICC for RV Ell (FW+S) was 0.92 and 0.80 respectively, while for RA peak strain was 0.92 and 0.89 respectively. Normal values of RV & RA deformation for healthy individuals using FT-CMR are provided with good RV Ell and RA peak strain reproducibility. Strain rate suffered from sub-optimal reproducibility and may not be satisfactory for clinical use. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  19. Effects of hand grip exercise on shoulder joint internal rotation and external rotation peak torque.

    Science.gov (United States)

    Lee, Dong-Rour; Jong-Soon Kim, Laurentius

    2016-08-10

    The goal of this study is to analyze the effects of hand grip training on shoulder joint internal rotation (IR)/external rotation (ER) peak torque for healthy people. The research was conducted on 23 healthy adults in their 20 s-30 s who volunteered to participate in the experiment. Hand grip power test was performed on both hands of the research subjects before/after the test to study changes in hand grip power. Isokinetic machine was used to measure the concentric IRPT (internal rotation peak torque) and concentric ERPT (external rotation peak torque) at the velocity of 60°/sec, 90°/sec, and 180°/sec before/after the test. Hand grip training was performed daily on the subject's right hand only for four weeks according to exercise program. Finally, hand grip power of both hands and the maximum torque values of shoulder joint IR/ER were measured before/after the test and analyzed. There was a statistically significant difference in the hand grip power of the right hand, which was subject to hand grip training, after the experiment. Also, statistically significant difference for shoulder ERPT was found at 60°/sec. Hand grip training has a positive effect on shoulder joint IRPT/ERPT and therefore can help strengthen muscles around the shoulder without using weight on the shoulder. Consequently, hand grip training would help maintain strengthen the muscles around the shoulder in the early phase of rehabilitation process after shoulder surgery.

  20. Optimization of a Compton-suppression system by escape-peak ratio

    International Nuclear Information System (INIS)

    Niu, H.; Chao, J.H.; Wu, S.-C.

    1996-01-01

    A Compton-suppression system consisting of an HPGe central detector surrounded by eight BGO scintillators in an annular geometry was assembled. This system is dedicated to in-beam γ-ray measurements. The ratios of full-energy to single-escape peak and full-energy of double-escape peak, at γ-rays of 2754, 4443 and 6130 keV, were used to derive associated suppression factors in order to optimize detection conditions of the system. The suppression factors derived both from the escape peak ratios and the corresponding peak-to-Compton ratios of the γ-ray spectra are compared and discussed. This optimization technique may be of great significance for analyzing complicated spectra, where high-energy γ-rays are considered for analytical use. (Author)

  1. Transrectal real-time tissue elastography targeted biopsy coupled with peak strain index improves the detection of clinically important prostate cancer.

    Science.gov (United States)

    Ma, Qi; Yang, Dong-Rong; Xue, Bo-Xin; Wang, Cheng; Chen, Han-Bin; Dong, Yun; Wang, Cai-Shan; Shan, Yu-Xi

    2017-07-01

    The focus of the present study was to evaluate transrectal real-time tissue elastography (RTE)-targeted two-core biopsy coupled with peak strain index for the detection of prostate cancer (PCa) and to compare this method with 10-core systematic biopsy. A total of 141 patients were enrolled for evaluation. The diagnostic value of peak strain index was assessed using a receiver operating characteristic curve. The cancer detection rates of the two approaches and corresponding positive cores and Gleason score were compared. The cancer detection rate per core in the RTE-targeted biopsy (44%) was higher compared with that in systematic biopsy (30%). The peak strain index value of PCa was higher compared with that of the benign lesion. PCa was detected with the highest sensitivity (87.5%) and specificity (85.5%) using the threshold value of a peak strain index of ≥5.97 with an area under the curve value of 0.95. When the Gleason score was ≥7, RTE-targeted biopsy coupled with peak strain index detected 95.6% of PCa cases, but 84.4% were detected using systematic biopsy. Peak strain index as a quantitative parameter may improve the differentiation of PCa from benign lesions in the prostate peripheral zone. Transrectal RTE-targeted biopsy coupled with peak strain index may enhance the detection of clinically significant PCa, particularly when combined with systematic biopsy.

  2. A comparative study of calculated and measured particle velocities

    International Nuclear Information System (INIS)

    Tariq, S.M.

    2005-01-01

    After an explosive is detonated in a blast hole, seismic waves are generated in the ground surrounding the blast hole. These waves cause the particles of rock to oscillate about its position. As the wave attenuate, the particles come back to their original position. The rapidity with which the particles move is called the particle velocity. The peak or maximum velocity is the value which is of prime concern. This value of peak particle velocity can be estimated by the equations determined by the United States Bureau of Mines and by the DUPONT. A research program was conducted by the author at the 'Beck Materials Quarry' situated near Rolla, Missouri, USA. The purpose was to draw a comparison between the predicted and measured particle velocities. It was generally found that the predicted peak particle velocities were quite high as compared to the velocities measured by the Seismographs. (author)

  3. A technique to measure the absorbed dose in human tooth enamel using EPR method

    International Nuclear Information System (INIS)

    Lanjanian, H.; Ziaie, F.; Modarresi, M.; Nikzad, M.; Shahvar, A.; Durrani, S.A.

    2008-01-01

    The EPR spectrum of irradiated tooth enamel contains a multitude of signals that are divided into two categories of radiation-induced and radiation insensitive (native) signals. At lower doses the broad native signal obscures the radiation-induced signal. In this work attempt has been made to find a method to measure the radiation-induced signal other than peak-to-peak signal amplitude measurement. For this reason software was programmed to extract the data from EPR system. The average amplitude of the radiation-induced EPR signal which is defined between the known g-values can also be calculated using the software. The result of this calculations were considered as the EPR response for the tooth enamel samples irradiated from 100 to 500 mGy and was drawn as the calibration curve. The resulted data as compared to the peak-to-peak amplitude measurement method seems to be more reproducible and shows a better variation against the dose values

  4. Measuring Children's Environmental Attitudes and Values in Northwest Mexico: Validating a Modified Version of Measures to Test the Model of Ecological Values (2-MEV)

    Science.gov (United States)

    Schneller, A. J.; Johnson, B.; Bogner, F. X.

    2015-01-01

    This paper describes the validation process of measuring children's attitudes and values toward the environment within a Mexican sample. We applied the Model of Ecological Values (2-MEV), which has been shown to be valid and reliable in 20 countries, including one Spanish speaking culture. Items were initially modified to fit the regional dialect,…

  5. Applicability of International and DOE Target Values to ALD Destructive Measurement Applications

    International Nuclear Information System (INIS)

    Holland, M.K.

    2002-01-01

    International Target values and target value applicability are a function of the nuclear material processing campaign or application for which the accountability measurement method is being applied. Safeguarding significant quantities of nuclear-grade materials requires that accountability measurements be as accurate, precise, and representative as practically possible. In general, the ITV provides a benchmark for determining generic acceptability of the performance of the various accountability measurement methods, since it represents a performance level that is accepted as highly reliable. There are cases where it is acceptable to select alternative accountability methods not specifically referenced by the ITV, or to use the recognized measurement method, even though the uncertainties are greater than the target values

  6. What is the peak stress in ceramic bar impacts?

    International Nuclear Information System (INIS)

    Simha, C. Hari Manoj; Bless, S.J.; Bedford, A.

    2000-01-01

    The bar impact experiment has been extensively used to characterize the high strain rate properties of high strength ceramics. In particular, alumina AD-99.5 has been widely studied; both stress gauge and VISAR bar impact data are available for this material. We have performed plate-on-bar impact experiments using this material in some novel configurations. An interface was introduced in the target bar (by cutting it) in the zone where the material fails by axial splitting. Such experiments resulted in a dramatic drop in the peak stress measured in the experiment, when compared to experiments with no interface. We show that the damage kinetics in tension influence these measurements. Since the peak stress is dependent on the damage kinetics we conclude that the measurement cannot be correlated to some intrinsic strength of the ceramic

  7. Finite element approximation for time-dependent diffusion with measure-valued source

    Czech Academy of Sciences Publication Activity Database

    Seidman, T.; Gobbert, M.; Trott, D.; Kružík, Martin

    2012-01-01

    Roč. 122, č. 4 (2012), s. 709-723 ISSN 0029-599X R&D Projects: GA AV ČR IAA100750802 Institutional support: RVO:67985556 Keywords : measure-valued source * diffusion equation Subject RIV: BA - General Mathematics Impact factor: 1.329, year: 2012 http://library.utia.cas.cz/separaty/2012/MTR/kruzik-finite element approximation for time - dependent diffusion with measure-valued source.pdf

  8. Superoxide dismutase levels and peak expiratory flow in asthmatic children

    Directory of Open Access Journals (Sweden)

    Arie Kurniasih

    2016-11-01

    Full Text Available Background Asthma is a chronic inflammatory process which involve variety of cells such as inflammatory mediators, reactive oxygen species (ROS, and cytokines. The inflammatory process would be exacerbated in the presence of oxidative stress. Superoxide dismutase (SOD is the first important enzyme to protect the respiratory tract against oxidative stress. The decreased of SOD has a correlation with increased of airway obstruction and bronchospasm. Objective To assess for a correlation between superoxide dismutase (SOD levels and peak expiratory flow, as well as to determine the impact of SOD levels for predicting asthma attacks. Methods We conducted a prospective cohort study at Dr. Sardjito Hospital, Yogyakarta, between February and April 2011 involving asthmatic children aged 5-18 years. Subjects’ serum SOD levels and peak expiratory flow were measured at the same time point. We then performed a prospective study following up on the same subjects to find out if they had a recurrent asthma attack within one month of the tests. We also reassessed their peak expiratory flow one month after blood specimens were obtained. Results Thirty-nine patients were enrolled in this study. There was no significant correlation between SOD level and peak expiratory flow [r=0.289; 95%CI -0.025 to 0.47; P=0.074]. However, older age was significantly associated with higher peak expiratory flow (=0.5; 95%CI 3.10 to 11.57; P=0.01. Lower levels of SOD increased the risk of asthma attacks in a month following the initial measurements (RR=5.5; 95%CI 1.6 to 18.9; P=0.009. Conclusion Superoxide dismutase (SOD level is not significantly associated with peak expiratory flow. However, we find a relationship between older age and higher peak expiratory flow and a relationship between lower SOD levels and risk of asthma attacks within one month following the tests.

  9. [Study of personal best value of peak expiratory flow in patients with asthma--comparison of the highest value of daily PEF under good control and the highest value of daily PEF obtained after using repeated inhaled beta2-agonist during high-dose inhaled steroid treatment].

    Science.gov (United States)

    Watanabe, Naoto; Makino, Sohei; Kihara, Norio; Fukuda, Takeshi

    2008-12-01

    In the guideline for asthma management, it is important to find the personal best value of peak expiratory flow (best PEF). Recently, we have substituted the highest value of PEF in daily life under good control (daily highest PEF) for the best PEF. In the present study, we considered whether the daily highest PEF could be used as the best PEF or not. Subjects were 30 asthmatics who were well controlled but whose baseline PEF values were less than 80 percent of predicted values. We compared the daily highest PEF and the highest of PEF obtained after repeated inhaled beta2-agonist (salbutamol MDI every 20 minutes three times). All subjects then received 1600 microg/day of beclomethasone dipropionate (BDP) for 4 to 8 weeks. We studied the effect of high-dose inhaled steroid treatment on each PEF value and compared the daily highest PEF and the highest PEF obtained after using repeated salbutamol MDI during high dose inhaled steroid therapy on the examination day again. The baseline PEF, daily highest PEF and the highest PEF obtained after salbutamol MDI were significantly less than the each values obtained after high-dose BDP. The best PEF value of them was the value obtained after repeated salbutamol MDI during high dose BDP. We suggest that the daily highest PEF under good control is not a substitute for best PEF because it changes according to the degree of improvement of airway inflammation. We recommend that a course of high dose inhaled steroid is effective in finding the best value of PEF for each individual with moderate asthma.

  10. Peak Oil and other threatening peaks-Chimeras without substance

    International Nuclear Information System (INIS)

    Radetzki, Marian

    2010-01-01

    The Peak Oil movement has widely spread its message about an impending peak in global oil production, caused by an inadequate resource base. On closer scrutiny, the underlying analysis is inconsistent, void of a theoretical foundation and without support in empirical observations. Global oil resources are huge and expanding, and pose no threat to continuing output growth within an extended time horizon. In contrast, temporary or prolonged supply crunches are indeed plausible, even likely, on account of growing resource nationalism denying access to efficient exploitation of the existing resource wealth.

  11. A new inductive method for measuring the RRR-value of niobium

    International Nuclear Information System (INIS)

    Bolore, M.; Bonin, B.; Boudigou, Y.; Heuveline, S.; Jacques, E.; Jaidane, S.; Koechlin, F.; Safa, H.

    1996-01-01

    A new method for measuring the RRR-value of niobium is presented. The principle of the measurement uses low frequency induction in a niobium sheet placed close to a pair of coils. In contrast with the usual resistive method, the present one gives information on the local value of the RRR, with a spatial resolution of the order of 1 cm. In addition, it is non destructive, thus opening the way to mapping RRR measurements on cavities. This tool will permit the measure of RRR inhomogeneities in cavities due to sheet forming or heat treatments, and the systematic check of the quality of weld seams. (author)

  12. Operational Risk Measurement of Chinese Commercial Banks Based on Extreme Value Theory

    Science.gov (United States)

    Song, Jiashan; Li, Yong; Ji, Feng; Peng, Cheng

    The financial institutions and supervision institutions have all agreed on strengthening the measurement and management of operational risks. This paper attempts to build a model on the loss of operational risks basing on Peak Over Threshold model, emphasizing on weighted least square, which improved Hill’s estimation method, while discussing the situation of small sample, and fix the sample threshold more objectively basing on the media-published data of primary banks loss on operational risk from 1994 to 2007.

  13. Measuring the Value of Placements to Employers: A Cost-Benefit Approach

    Science.gov (United States)

    Wond, Tracey; Rambukwella, Shan

    2018-01-01

    This article explores the concept and measurement of placement value, underexplored in theory and practice to date. The article makes a theoretical contribution to the placement value discourse by examining and articulating the placement value concept. It also offers a practical contribution by exploring a piloted tool to evaluate employer…

  14. The Impact of Corporate Governance on Financial Performance: (Measured using Accounting and Value-Added based Measures): Evidence from Malaysia

    OpenAIRE

    Abdul Aziz, Khairul Annuar

    2005-01-01

    This paper aims to test empirically which measure, an accounting based financial performance measure such as Return on Equity, Price to Earnings Ratio, Earnings Per Share and Return on Capital Employed; or value-added based financial performance measures such as Economic Value Added and Market Value Added; is more closely related with Corporate Governance Compliance. This paper also aims to study the level of Corporate Governance Compliance of the Smaller Companies listed on the KLSE, the mea...

  15. Peak-locking reduction for particle image velocimetry

    International Nuclear Information System (INIS)

    Michaelis, Dirk; Wieneke, Bernhard; Neal, Douglas R

    2016-01-01

    A parametric study of the factors contributing to peak-locking, a known bias error source in particle image velocimetry (PIV), is conducted using synthetic data that are processed with a state-of-the-art PIV algorithm. The investigated parameters include: particle image diameter, image interpolation techniques, the effect of asymmetric versus symmetric window deformation, number of passes and the interrogation window size. Some of these parameters are found to have a profound effect on the magnitude of the peak-locking error. The effects for specific PIV cameras are also studied experimentally using a precision turntable to generate a known rotating velocity field. Image time series recorded using this experiment show a linear range of pixel and sub-pixel shifts ranging from 0 to  ±4 pixels. Deviations in the constant vorticity field (ω z ) reveal how peak-locking can be affected systematically both by varying parameters of the detection system such as the focal distance and f -number, and also by varying the settings of the PIV analysis. A new a priori technique for reducing the bias errors associated with peak-locking in PIV is introduced using an optical diffuser to avoid undersampled particle images during the recording of the raw images. This technique is evaluated against other a priori approaches using experimental data and is shown to perform favorably. Finally, a new a posteriori anti peak-locking filter (APLF) is developed and investigated, which shows promising results for both synthetic data and real measurements for very small particle image sizes. (paper)

  16. Energy shifts in the binary encounter peak of 0.5 MeV/amu Cuq+ +H2

    International Nuclear Information System (INIS)

    Hidmi, H.I.; Richard, P.; Sanders, J.M.; Zouros, T.J.M.

    1993-01-01

    The energy shifts from the classical prediction in the binary encounter peak of Cu q+ as a function of the charge state q has been experimentally measured. The data showed that this shift increases by increasing the charge state of the projectile. We fitted the energy shift to an equation of the form ΔE=aq n and obtained a value for the exponent n. The data is also compared to the Bohr-Lindhard calculation which predicts an exponent n=0.5. Good agreement was found between our data and the Bohr-Lindhard model

  17. International Target Values 2010 for Measurement Uncertainties in Safeguarding Nuclear Materials

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, M.; Penkin, M.; Norman, C.; Balsley, S. [IAEA, Vienna (Australia); others, and

    2012-12-15

    This issue of the International Target Values (ITVs) represents the sixth revision, following the first release of such tables issued in 1979 by the ESARDA/WGDA. The ITVs are uncertainties to be considered in judging the reliability of analytical techniques applied to industrial nuclear and fissile material, which are subject to safeguards verification. The tabulated values represent estimates of the 'state of the practice' which should be achievable under routine measurement conditions. The most recent standard conventions in representing uncertainty have been considered, while maintaining a format that allows comparison with the previous releases of the ITVs. The present report explains why target values are needed, how the concept evolved and how they relate to the operator's and inspector's measurement systems. The ITVs-2010 are intended to be used by plant operators and safeguards organizations, as a reference of the quality of measurements achievable in nuclear material accountancy, and for planning purposes. The report suggests that the use of ITVs can be beneficial for statistical inferences regarding the significance of operator-inspector differences whenever valid performance values are not available.

  18. CORRECTION OF GLOBAL AND REFLEX RADIATION VALUES MEASURED ABOVE THE LAKE BALATON

    Directory of Open Access Journals (Sweden)

    Laszlo Menyhart

    2014-03-01

    Full Text Available Albedo measurements have been carried out since 2007 above the Lake Balaton near Keszthely and Siofok. It turned out that a systematic offset error was superposed to both the global and the reflex radiation. The value of this systematic error was approximately constant per pyranometer within a year but on the other hand it varied from year to year and from pyranometer to pyranometer. In this paper the values of this systematic errors were determined with two different methods. The difference between the values measured at night-time and the intrinsic thermal offset error of pyranometers were examined with both methods. The base of the first method is the empirical observation, that the values measured at night-time by a global radiometer are typically negative whereas by a reflex radiometer are typically positive. The substance of the second method is utilizing the air temperature measured within 1 as well as 5 hours before the radiation measuring to +select the fully overcast nights, when the thermal offset error of the global radiometer is zero. In addition, the cases where the thermal offset error of the reflex radiometer is zero were selected on the basis of the difference between water and air temperature. When the thermal offset error is zero the measured value is equal to the systematic error. Comparing the results of the two methods showed that the systematic error of the global radiometer were determined with uncertainty of 1 Wm–2, whereas that of the reflex radiometer with uncertainty of 2 Wm–2. The calibration constants were recalculated from the values being in the calibration reports taking the systematic errors into account.

  19. Modeling of Lightning Strokes Using Two-Peaked Channel-Base Currents

    Directory of Open Access Journals (Sweden)

    V. Javor

    2012-01-01

    Full Text Available Lightning electromagnetic field is obtained by using “engineering” models of lightning return strokes and new channel-base current functions and the results are presented in this paper. Experimentally measured channel-base currents are approximated not only with functions having two-peaked waveshapes but also with the one-peaked function so as usually used in the literature. These functions are simple to be applied in any “engineering” or electromagnetic model as well. For the three “engineering” models: transmission line model (without the peak current decay, transmission line model with linear decay, and transmission line model with exponential decay with height, the comparison of electric and magnetic field components at different distances from the lightning channel-base is presented in the case of a perfectly conducting ground. Different heights of lightning channels are also considered. These results enable analysis of advantages/shortages of the used return stroke models according to the electromagnetic field features to be achieved, as obtained by measurements.

  20. Enhanced vegetation growth peak and its key mechanisms

    Science.gov (United States)

    Huang, K.; Xia, J.; Wang, Y.; Ahlström, A.; Schwalm, C.; Huntzinger, D. N.; Chen, J.; Cook, R. B.; Fang, Y.; Fisher, J. B.; Jacobson, A. R.; Michalak, A.; Schaefer, K. M.; Wei, Y.; Yan, L.; Luo, Y.

    2017-12-01

    It remains unclear that whether and how the vegetation growth peak has been shifted globally during the past three decades. Here we used two global datasets of gross primary productivity (GPP) and a satellite-derived Normalized Difference Vegetation Index (NDVI) to characterize recent changes in seasonal peak vegetation growth. The attribution of changes in peak growth to their driving factors was examined with several datasets. We demonstrated that the growth peak of global vegetation has been linearly increasing during the past three decades. About 65% of this trend is evenly explained by the expanding croplands (21%), rising atmospheric [CO2] (22%), and intensifying nitrogen deposition (22%). The contribution of expanding croplands to the peak growth trend was substantiated by measurements from eddy-flux towers, sun-induced chlorophyll fluorescence and a global database of plant traits, all of which demonstrated that croplands have a higher photosynthetic capacity than other vegetation types. The contribution of rising atmospheric [CO2] and nitrogen deposition are consistent with the positive response of leaf growth to elevated [CO2] (25%) and nitrogen addition (8%) from 346 manipulated experiments. The positive effect of rising atmospheric [CO2] was also well captured by 15 terrestrial biosphere models. However, most models underestimated the contributions of land-cover change and nitrogen deposition, but overestimated the positive effect of climate change.

  1. Accurate Estimation of Low Fundamental Frequencies from Real-Valued Measurements

    DEFF Research Database (Denmark)

    Christensen, Mads Græsbøll

    2013-01-01

    In this paper, the difficult problem of estimating low fundamental frequencies from real-valued measurements is addressed. The methods commonly employed do not take the phenomena encountered in this scenario into account and thus fail to deliver accurate estimates. The reason for this is that the......In this paper, the difficult problem of estimating low fundamental frequencies from real-valued measurements is addressed. The methods commonly employed do not take the phenomena encountered in this scenario into account and thus fail to deliver accurate estimates. The reason...... for this is that they employ asymptotic approximations that are violated when the harmonics are not well-separated in frequency, something that happens when the observed signal is real-valued and the fundamental frequency is low. To mitigate this, we analyze the problem and present some exact fundamental frequency estimators...

  2. Decreased peak expiratory flow in pediatric passive smokers

    Directory of Open Access Journals (Sweden)

    Fitri Yanti

    2011-08-01

    Full Text Available Background Indonesia ranks fifth among countries with the highest aggregate levels of tobacco consumption in the world. Infants and children exposed to environmental tobacco smoke have increased rates of asthma, respiratory and ear infections, as well as reduced lung function. The effects of tobacco smoke exposure on lung function in children have been reported to be dependent on the source of smoke and the length and dose of exposure. Lung function may also be affected by a child’s gender and asthma status. Objective To compare peak expiratory flow (PEF in pediatric passive smokers to that of children not exposed to second hand smoke, and to define factors that may affect PEF in passive smokers. Methods In August 2009 we conducted a cross-sectional study at an elementary school in the Langkat district. Subjects were aged 6 to 12 years, and divided into two groups: passive smokers and those not exposed to secondhand smoke. Subjects’ PEFs were measured with a Mini-Wright peak flow meter. Measurements were performed in triplicate with the highest value recorded as the PEF. Demographic data including age, sex, weight, height, family income, parental education levels and occupations were obtained through questionnaires. Results Of the 170 participants, 100 were passive smokers and 70 were not exposed to secondhand smoke. Age distribution, weight and height were similar in both groups. We observed a significant difference in PEFs between the group of passive smokers and the group not exposed to secondhand smoke, 211.3 L/minute (SD 61.08 and 242.7 L/minute (SD 77.09, respectively (P < 0.005. The number of years of exposure to smoke (P = 0.079 and the number of cigarettes smoked daily in the household (P = 0.098 did not significantly influence PEF. Conclusion The PEF in pediatric passive smokers was significantly lower than that of children not exposed to secondhand smoke. PEF in passive smokers was not influenced by the number of years of smoke

  3. Daily Peak Load Forecasting of Next Day using Weather Distribution and Comparison Value of Each Nearby Date Data

    Science.gov (United States)

    Ito, Shigenobu; Yukita, Kazuto; Goto, Yasuyuki; Ichiyanagi, Katsuhiro; Nakano, Hiroyuki

    By the development of industry, in recent years; dependence to electric energy is growing year by year. Therefore, reliable electric power supply is in need. However, to stock a huge amount of electric energy is very difficult. Also, there is a necessity to keep balance between the demand and supply, which changes hour after hour. Consequently, to supply the high quality and highly dependable electric power supply, economically, and with high efficiency, there is a need to forecast the movement of the electric power demand carefully in advance. And using that forecast as the source, supply and demand management plan should be made. Thus load forecasting is said to be an important job among demand investment of electric power companies. So far, forecasting method using Fuzzy logic, Neural Net Work, Regression model has been suggested for the development of forecasting accuracy. Those forecasting accuracy is in a high level. But to invest electric power in higher accuracy more economically, a new forecasting method with higher accuracy is needed. In this paper, to develop the forecasting accuracy of the former methods, the daily peak load forecasting method using the weather distribution of highest and lowest temperatures, and comparison value of each nearby date data is suggested.

  4. A Framework for Understanding and Generating Integrated Solutions for Residential Peak Energy Demand

    Science.gov (United States)

    Buys, Laurie; Vine, Desley; Ledwich, Gerard; Bell, John; Mengersen, Kerrie; Morris, Peter; Lewis, Jim

    2015-01-01

    Supplying peak energy demand in a cost effective, reliable manner is a critical focus for utilities internationally. Successfully addressing peak energy concerns requires understanding of all the factors that affect electricity demand especially at peak times. This paper is based on past attempts of proposing models designed to aid our understanding of the influences on residential peak energy demand in a systematic and comprehensive way. Our model has been developed through a group model building process as a systems framework of the problem situation to model the complexity within and between systems and indicate how changes in one element might flow on to others. It is comprised of themes (social, technical and change management options) networked together in a way that captures their influence and association with each other and also their influence, association and impact on appliance usage and residential peak energy demand. The real value of the model is in creating awareness, understanding and insight into the complexity of residential peak energy demand and in working with this complexity to identify and integrate the social, technical and change management option themes and their impact on appliance usage and residential energy demand at peak times. PMID:25807384

  5. Pain severity is associated with muscle strength and peak oxygen uptake in adults with fibromyalgia

    Directory of Open Access Journals (Sweden)

    Hooten WM

    2014-05-01

    Full Text Available W Michael Hooten,1,2 Jolene M Smith,3 Jason S Eldrige,1 David A Olsen,3 W David Mauck,1 Susan M Moeschler11Department of Anesthesiology, 2Department of Psychiatry and Psychology, Mayo Clinic College of Medicine, 3Mayo School of Graduate Medical Education, Rochester, MN, USABackground: The associations between pain, lower extremity strength, and aerobic conditioning have not been widely investigated in adults with fibromyalgia (FM. The principle objective of this study was to investigate the relationship between pain severity and knee strength in patients seeking treatment for FM. A secondary objective was to investigate the relationship between pain scores and aerobic conditioning.Methods: Three measures of knee strength (isokinetic extensor, isokinetic flexor, isometric extensor were quantified in the dominant leg of 69 adults with FM using a dynamometer at speeds of 60 degrees per second (60°/s and 180°/s. Peak oxygen uptake (VO2 was assessed using a cycle ergometer, and pain was assessed using the pain severity subscale of the Multidimensional Pain Inventory.Results: In univariable linear regression analyses using pain severity as the dependent variable, lesser values of isokinetic knee extensor strength at 60°/s (P=0.041 and 180°/s (P=0.010, isokinetic knee flexor strength at 60°/s (P=0.028 and 180°/s (P=0.003, and peak VO2 uptake (P=0.031 were predictive of greater pain severity scores. In multiple variable linear regression models adjusted for age, sex, body mass index, and opioid use, the following associations retained statistical significance; isokinetic knee extensor strength at 60°/s (P=0.020 and 180°/s (P=0.003, isokinetic knee flexor strength at 60°/s (P=0.015 and 180°/s (P=0.001, and peak VO2 uptake (P=0.014. However, no significant associations were found between pain severity and isometric knee extensor strength.Conclusion: The main findings from this study were that lesser values of isokinetic knee strength and peak VO

  6. The impact of gender and puberty on reference values for urinary growth hormone excretion

    DEFF Research Database (Denmark)

    Main, K M; Jarden, M; Angelo, L

    1994-01-01

    , which allows direct measurement of U-GH in untreated urine specimens. We established a reference range for the geometric mean of 3 morning urine samples in 446 healthy children and 71 adults. U-GH could be determined in all but 9 of 1526 samples (99.4%). U-GH excretion was significantly dependent...... on pubertal maturation (P 0.3). Peak values occurred in Tanner stages 3 and 4 (369 and 391 pg/h in females; 503 and 882 pg/h in males), corresponding to an age interval of 11-18 yr in boys and 9-15 yr in girls...... of the pubertal peak, and lower values in adults than in prepubertal children (P

  7. The use of personal values in living standards measures | Ungerer ...

    African Journals Online (AJOL)

    The Living Standards Measure (LSM), a South African marketing segmentation method, is a multivariate wealth measure based on standard of living. This article reports on whether a rationale can be found for the inclusion of psychological variables, particularly personal values, in this type of multivariate segmentation.

  8. Determination of concentric and eccentric peak moment values for trunk flexion and extension in sedentary asymptomatic individuals by isokinetic dynamometry: a pilot study

    Directory of Open Access Journals (Sweden)

    Rafaella Stradiotto Bernardelli

    2017-11-01

    Full Text Available The spine has a direct influence on postural alignment and movement of the whole body. Lumbar muscles constitute a critical element in trunk performance while weakness of these muscles has been associated with low back pain. Hence, strength profiling of trunk muscles is clinically significant. The objective of this research was to determine, by means of isokinetic dynamometry, peak moment (PM values during isokinetic concentric and eccentric efforts of trunk flexion and extension in sedentary asymptomatic individuals. The sample consisted of 100 asymptomatic sedentary volunteers, fifty from each sex, aging 22.2 ± 3.3 years old. The sample underwent concentric and eccentric isokinetic assessment of the trunk flexor and extensor muscles at an angular velocity of 60 degrees/sec for each mode of contraction. The mean concentric PM for trunk flexion and extension were 139.5 and 166.6 Nm, respectively, while the respective values for the eccentric efforts were 188.8 and 221.2 Nm. The PM flexion/extension ratio was 0.87 and 0.89 for the concentric and eccentric efforts, respectively. These values of concentric and eccentric PM and PM ratio will serve as comparison parameters for future research, as well as for the assessment of symptomatic patients, and to help in the creation of the trunk muscle rebalance protocols.

  9. Magnetic Field-Vector Measurements in Quiescent Prominences via the Hanle Effect: Analysis of Prominences Observed at Pic-Du-Midi and at Sacramento Peak

    Science.gov (United States)

    Bommier, V.; Leroy, J. L.; Sahal-Brechot, S.

    1985-01-01

    The Hanle effect method for magnetic field vector diagnostics has now provided results on the magnetic field strength and direction in quiescent prominences, from linear polarization measurements in the He I E sub 3 line, performed at the Pic-du-Midi and at Sacramento Peak. However, there is an inescapable ambiguity in the field vector determination: each polarization measurement provides two field vector solutions symmetrical with respect to the line-of-sight. A statistical analysis capable of solving this ambiguity was applied to the large sample of prominences observed at the Pic-du-Midi (Leroy, et al., 1984); the same method of analysis applied to the prominences observed at Sacramento Peak (Athay, et al., 1983) provides results in agreement on the most probable magnetic structure of prominences; these results are detailed. The statistical results were confirmed on favorable individual cases: for 15 prominences observed at Pic-du-Midi, the two-field vectors are pointing on the same side of the prominence, and the alpha angles are large enough with respect to the measurements and interpretation inaccuracies, so that the field polarity is derived without any ambiguity.

  10. Achievable peak electrode voltage reduction by neurostimulators using descending staircase currents to deliver charge.

    Science.gov (United States)

    Halpern, Mark

    2011-01-01

    This paper considers the achievable reduction in peak voltage across two driving terminals of an RC circuit when delivering charge using a stepped current waveform, comprising a chosen number of steps of equal duration, compared with using a constant current over the total duration. This work has application to the design of neurostimulators giving reduced peak electrode voltage when delivering a given electric charge over a given time duration. Exact solutions for the greatest possible peak voltage reduction using two and three steps are given. Furthermore, it is shown that the achievable peak voltage reduction, for any given number of steps is identical for simple series RC circuits and parallel RC circuits, for appropriate different values of RC. It is conjectured that the maximum peak voltage reduction cannot be improved using a more complicated RC circuit.

  11. A novel fast phase correlation algorithm for peak wavelength detection of Fiber Bragg Grating sensors.

    Science.gov (United States)

    Lamberti, A; Vanlanduit, S; De Pauw, B; Berghmans, F

    2014-03-24

    Fiber Bragg Gratings (FBGs) can be used as sensors for strain, temperature and pressure measurements. For this purpose, the ability to determine the Bragg peak wavelength with adequate wavelength resolution and accuracy is essential. However, conventional peak detection techniques, such as the maximum detection algorithm, can yield inaccurate and imprecise results, especially when the Signal to Noise Ratio (SNR) and the wavelength resolution are poor. Other techniques, such as the cross-correlation demodulation algorithm are more precise and accurate but require a considerable higher computational effort. To overcome these problems, we developed a novel fast phase correlation (FPC) peak detection algorithm, which computes the wavelength shift in the reflected spectrum of a FBG sensor. This paper analyzes the performance of the FPC algorithm for different values of the SNR and wavelength resolution. Using simulations and experiments, we compared the FPC with the maximum detection and cross-correlation algorithms. The FPC method demonstrated a detection precision and accuracy comparable with those of cross-correlation demodulation and considerably higher than those obtained with the maximum detection technique. Additionally, FPC showed to be about 50 times faster than the cross-correlation. It is therefore a promising tool for future implementation in real-time systems or in embedded hardware intended for FBG sensor interrogation.

  12. Peak fitting and identification software library for high resolution gamma-ray spectra

    International Nuclear Information System (INIS)

    Uher, Josef; Roach, Greg; Tickner, James

    2010-01-01

    A new gamma-ray spectral analysis software package is under development in our laboratory. It can be operated as a stand-alone program or called as a software library from Java, C, C++ and MATLAB TM environments. It provides an advanced graphical user interface for data acquisition, spectral analysis and radioisotope identification. The code uses a peak-fitting function that includes peak asymmetry, Compton continuum and flexible background terms. Peak fitting function parameters can be calibrated as functions of energy. Each parameter can be constrained to improve fitting of overlapping peaks. All of these features can be adjusted by the user. To assist with peak identification, the code can automatically measure half-lives of single or multiple overlapping peaks from a time series of spectra. It implements library-based peak identification, with options for restricting the search based on radioisotope half-lives and reaction types. The software also improves the reliability of isotope identification by utilizing Monte-Carlo simulation results.

  13. Experimental Study on Peak Pressure of Shock Waves in Quasi-Shallow Water

    Directory of Open Access Journals (Sweden)

    Zhenxiong Wang

    2015-01-01

    Full Text Available Based on the similarity laws of the explosion, this research develops similarity requirements of the small-scale experiments of underwater explosions and establishes a regression model for peak pressure of underwater shock waves under experimental condition. Small-scale experiments are carried out with two types of media at the bottom of the water and for different water depths. The peak pressure of underwater shock waves at different measuring points is acquired. A formula consistent with the similarity law of explosions is obtained and an analysis of the regression precision of the formula confirms its accuracy. Significance experiment indicates that the influence of distance between measuring points and charge on peak pressure of underwater shock wave is the greatest and that of water depth is the least within the range of geometric parameters. An analysis of data from experiments with different media at the bottom of the water reveals an influence on the peak pressure, as the peak pressure of a shock wave in a body of water with a bottom soft mud and rocks is about 1.33 times that of the case where the bottom material is only soft mud.

  14. Reference value sensitivity of measures of unfair health inequality

    Science.gov (United States)

    García-Gómez, Pilar; Schokkaert, Erik; Van Ourti, Tom

    2014-01-01

    Most politicians and ethical observers are not interested in pure health inequalities, as they want to distinguish between different causes of health differences. Measures of “unfair” inequality - direct unfairness and the fairness gap, but also the popular standardized concentration index - therefore neutralize the effects of what are considered to be “legitimate” causes of inequality. This neutralization is performed by putting a subset of the explanatory variables at reference values, e.g. their means. We analyze how the inequality ranking of different policies depends on the specific choice of reference values. We show with mortality data from the Netherlands that the problem is empirically relevant and we suggest a statistical method for fixing the reference values. PMID:24954998

  15. Predictive value of proteinuria in adult dengue severity.

    Directory of Open Access Journals (Sweden)

    Farhad F Vasanwala

    2014-02-01

    Full Text Available BACKGROUND: Dengue is an important viral infection with different presentations. Predicting disease severity is important in triaging patients requiring hospital care. We aim to study the value of proteinuria in predicting the development of dengue hemorrhagic fever (DHF, utility of urine dipstick test as a rapid prognostic tool. METHODOLOGY AND PRINCIPAL FINDINGS: Adult patients with undifferentiated fever (n = 293 were prospectively enrolled at the Infectious Disease Research Clinic at Tan Tock Seng Hospital, Singapore from January to August 2012. Dengue infection was confirmed in 168 (57% by dengue RT-PCR or NS1 antigen detection. Dengue cases had median fever duration of 6 days at enrollment. DHF was diagnosed in 34 cases according to the WHO 1997 guideline. Dengue fever (DF patients were predominantly younger and were mostly seen in the outpatient setting with higher platelet level. Compared to DF, DHF cases had significantly higher peak urine protein creatinine ratio (UPCR during clinical course (26 vs. 40 mg/mmol; p<0.001. We obtained a UPCR cut-off value of 29 mg/mmol based on maximum AUC in ROC curves of peak UPCR for DF versus DHF, corresponding to 76% sensitivity and 60% specificity. Multivariate analysis with other readily available clinical and laboratory variables increased the AUC to 0.91 with 92% sensitivity and 80% specificity. Neither urine dipstick at initial presentation nor peak urine dipstick value during the entire illness was able to discriminate between DF and DHF. CONCLUSIONS: Proteinuria measured by a laboratory-based UPCR test may be sensitive and specific in prognosticating adult dengue patients.

  16. Study and development of 22 kW peak power fiber coupled short pulse Nd:YAG laser for cleaning applications

    Science.gov (United States)

    Choubey, Ambar; Vishwakarma, S. C.; Vachhani, D. M.; Singh, Ravindra; Misra, Pushkar; Jain, R. K.; Arya, R.; Upadhyaya, B. N.; Oak, S. M.

    2014-11-01

    Free running short pulse Nd:YAG laser of microsecond pulse duration and high peak power has a unique capability to ablate material from the surface without heat propagation into the bulk. Applications of short pulse Nd:YAG lasers include cleaning and restoration of marble, stones, and a variety of metals for conservation. A study on the development of high peak power short pulses from Nd:YAG laser along with its cleaning and conservation applications has been performed. A pulse energy of 1.25 J with 55 μs pulse duration and a maximum peak power of 22 kW has been achieved. Laser beam has an M2 value of ~28 and a pulse-to-pulse stability of ±2.5%. A lower value of M2 means a better beam quality of the laser in multimode operation. A top hat spatial profile of the laser beam was achieved at the exit end of 200 μm core diameter optical fiber, which is desirable for uniform cleaning. This laser system has been evaluated for efficient cleaning of surface contaminations on marble, zircaloy, and inconel materials for conservation with cleaning efficiency as high as 98%. Laser's cleaning quality and efficiency have been analysed by using a microscope, a scanning electron microscope (SEM), and X-ray photon spectroscopy (XPS) measurements.

  17. Reversal of asymmetry of X-ray peak profiles from individual grains during a strain path change

    DEFF Research Database (Denmark)

    Wejdemann, Christian; Lienert, U.; Pantleon, Wolfgang

    2010-01-01

    X-ray peak profiles are measured from individual bulk grains during tensile deformation. Two differently oriented copper samples pre-deformed in tension show the expected peak profile asymmetry caused by intra-grain stresses. One of the samples is oriented to achieve a significant change of the i......X-ray peak profiles are measured from individual bulk grains during tensile deformation. Two differently oriented copper samples pre-deformed in tension show the expected peak profile asymmetry caused by intra-grain stresses. One of the samples is oriented to achieve a significant change...

  18. Measurement of use value and non-use value of environmental quality consistent with general equilibrium approach

    OpenAIRE

    Naoki Sakamoto; Kazunori Nakajima

    2014-01-01

    This paper proposes the consistent method with general equilibrium models to measure use value and non-use value of large-scale change in environmental quality. First, we develop a general equilibrium model that parameters of the utility function with environmental quality as a dependent variable can be estimated on the basis of the travel cost method and the contingent variation method. Second, we examine to identify the general equilibrium impact of environmental quality by a comparative st...

  19. The GRB variability/peak luminosity correlation: new results

    International Nuclear Information System (INIS)

    Guidorzi, C.; Rossi, F.; Hurley, K.; Mundell, C.G.

    2005-01-01

    We test the correlation between time variability and isotropic-equivalent peak luminosity found by Reichart et al. (ApJ, 552 (2001) 57) using a set of 26 Gamma-Ray Bursts (GRBs) with known redshift. We confirm the correlation, thought with a larger spread around the best-fit power-law obtained by Reichart et al. which in turn does not provide an acceptable description any longer. In addiction, we find no evidence for correlation between variability and beaming-corrected peak luminosity for a subset of 14 GRBs whose beaming angles have been taken from Ghirlanda et al. (ApJ, 616 (2004) 331). Finally, we investigate the possible connection for some GRBs between the location in the variability/peak luminosity space and some afterglow properties, such as the detectability in the optical band, by adding some GRBs whose redshifts, unknown from direct measurements, have been derived assuming the Amati at al. (AeA, 390 (2002) 81) relationship

  20. Simulation of the peak efficiency for a stacked NaI(Tl) spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, H; Murohka, H; Anami, K; Nohtomi, A; Uozumi, Y; Sakae, T; Matoba, M [Kyushu Univ., Fukuoka (Japan). Faculty of Engineering; Koori, N; Maki, T

    1996-07-01

    A stacked NaI(Tl) spectrometer has been developed to measure proton spectra in wide energy range. In the measurement of charged particles with intermediate energy, the detecting efficiency of the spectrometer decreases considerably due to nuclear reactions or out-scattering in the detector material. A Monte Carlo simulation code has been developed to estimate the peak efficiency (peak-to-total ratio) of the spectrometer. The calculated efficiency for intermediate energy is in good agreement with the experimental one. (author)

  1. Prognostic and diagnostic value of EEG signal coupling measures in coma.

    Science.gov (United States)

    Zubler, Frederic; Koenig, Christa; Steimer, Andreas; Jakob, Stephan M; Schindler, Kaspar A; Gast, Heidemarie

    2016-08-01

    Our aim was to assess the diagnostic and predictive value of several quantitative EEG (qEEG) analysis methods in comatose patients. In 79 patients, coupling between EEG signals on the left-right (inter-hemispheric) axis and on the anterior-posterior (intra-hemispheric) axis was measured with four synchronization measures: relative delta power asymmetry, cross-correlation, symbolic mutual information and transfer entropy directionality. Results were compared with etiology of coma and clinical outcome. Using cross-validation, the predictive value of measure combinations was assessed with a Bayes classifier with mixture of Gaussians. Five of eight measures showed a statistically significant difference between patients grouped according to outcome; one measure revealed differences in patients grouped according to the etiology. Interestingly, a high level of synchrony between the left and right hemisphere was associated with mortality on intensive care unit, whereas higher synchrony between anterior and posterior brain regions was associated with survival. The combination with the best predictive value reached an area-under the curve of 0.875 (for patients with post anoxic encephalopathy: 0.946). EEG synchronization measures can contribute to clinical assessment, and provide new approaches for understanding the pathophysiology of coma. Prognostication in coma remains a challenging task. qEEG could improve current multi-modal approaches. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  2. Probabilistic Model for Untargeted Peak Detection in LC-MS Using Bayesian Statistics.

    Science.gov (United States)

    Woldegebriel, Michael; Vivó-Truyols, Gabriel

    2015-07-21

    We introduce a novel Bayesian probabilistic peak detection algorithm for liquid chromatography-mass spectroscopy (LC-MS). The final probabilistic result allows the user to make a final decision about which points in a chromatogram are affected by a chromatographic peak and which ones are only affected by noise. The use of probabilities contrasts with the traditional method in which a binary answer is given, relying on a threshold. By contrast, with the Bayesian peak detection presented here, the values of probability can be further propagated into other preprocessing steps, which will increase (or decrease) the importance of chromatographic regions into the final results. The present work is based on the use of the statistical overlap theory of component overlap from Davis and Giddings (Davis, J. M.; Giddings, J. Anal. Chem. 1983, 55, 418-424) as prior probability in the Bayesian formulation. The algorithm was tested on LC-MS Orbitrap data and was able to successfully distinguish chemical noise from actual peaks without any data preprocessing.

  3. A 800 kV compact peaking capacitor for nanosecond generator.

    Science.gov (United States)

    Jia, Wei; Chen, Zhiqiang; Tang, Junping; Chen, Weiqing; Guo, Fan; Sun, Fengrong; Li, Junna; Qiu, Aici

    2014-09-01

    An extremely compact high voltage peaking capacitor is developed. The capacitor has a pancake structure with a diameter of 315 mm, a thickness of 59 mm, and a mass of 6.1 kg. The novel structural design endows the capacitor with a better mechanical stability and reliability under hundreds of kilovolts pulse voltage and an inner gas pressure of more than 1.5 MPa. The theoretical value of the capacitor self-inductance is near to 17 nH. Proved by series of electrical experiments, the capacitor can endure a high-voltage pulse with a rise time of about 20 ns, a half-width duration of around 25 ns, and an amplitude of up to 800 kV in a single shot model. When the capacitor was used in an electromagnetic pulse simulator as a peaking capacitor, the rise time of the voltage pulse can be reduced from 20 ns to less than 3 ns. The practical value of the capacitor's inductance deduced from the experimental date is no more than 25 nH.

  4. Clustering of reads with alignment-free measures and quality values.

    Science.gov (United States)

    Comin, Matteo; Leoni, Andrea; Schimd, Michele

    2015-01-01

    The data volume generated by Next-Generation Sequencing (NGS) technologies is growing at a pace that is now challenging the storage and data processing capacities of modern computer systems. In this context an important aspect is the reduction of data complexity by collapsing redundant reads in a single cluster to improve the run time, memory requirements, and quality of post-processing steps like assembly and error correction. Several alignment-free measures, based on k-mers counts, have been used to cluster reads. Quality scores produced by NGS platforms are fundamental for various analysis of NGS data like reads mapping and error detection. Moreover future-generation sequencing platforms will produce long reads but with a large number of erroneous bases (up to 15 %). In this scenario it will be fundamental to exploit quality value information within the alignment-free framework. To the best of our knowledge this is the first study that incorporates quality value information and k-mers counts, in the context of alignment-free measures, for the comparison of reads data. Based on this principles, in this paper we present a family of alignment-free measures called D (q) -type. A set of experiments on simulated and real reads data confirms that the new measures are superior to other classical alignment-free statistics, especially when erroneous reads are considered. Also results on de novo assembly and metagenomic reads classification show that the introduction of quality values improves over standard alignment-free measures. These statistics are implemented in a software called QCluster (http://www.dei.unipd.it/~ciompin/main/qcluster.html).

  5. Multiple negative differential resistance devices with ultra-high peak-to-valley current ratio for practical multi-valued logic and memory applications

    Science.gov (United States)

    Shin, Sunhae; Rok Kim, Kyung

    2015-06-01

    In this paper, we propose a novel multiple negative differential resistance (NDR) device with ultra-high peak-to-valley current ratio (PVCR) over 106 by combining tunnel diode with a conventional MOSFET, which suppresses the valley current with transistor off-leakage level. Band-to-band tunneling (BTBT) in tunnel junction provides the first peak, and the second peak and valley are generated from the suppression of diffusion current in tunnel diode by the off-state MOSFET. The multiple NDR curves can be controlled by doping concentration of tunnel junction and the threshold voltage of MOSFET. By using complementary multiple NDR devices, five-state memory is demonstrated only with six transistors.

  6. Prognostic Value of Exercise-Stress Echocardiography in Asymptomatic Patients With Aortic Valve Stenosis.

    Science.gov (United States)

    Goublaire, Coppelia; Melissopoulou, Maria; Lobo, David; Kubota, Naozumi; Verdonk, Constance; Cimadevilla, Claire; Codogno, Isabelle; Brochet, Eric; Vahanian, Alec; Messika-Zeitoun, David

    2017-07-19

    This study sought to evaluate the prognostic value of mean pressure gradient (MPG) increase and peak systolic pulmonary artery pressure (SPAP) measured during exercise stress echocardiography in asymptomatic patients with aortic stenosis (AS). Exercise testing is recommended in asymptomatic AS patients, but the additional value of exercise-stress echocardiography, especially the prognostic value of MPG increase and peak SPAP, is still debated. We enrolled all consecutive patients with pure, isolated, asymptomatic AS and preserved ejection fraction ≥50% and normal SPAP (20 mm Hg and/or SPAP at peak exercise >60 mm Hg). These 112 patients were managed conservatively. During a mean follow-up of 14 ± 8 months, an AS-related event occurred in 30 patients, and 25 patients underwent surgery. Neither MPG increase >20 mm Hg nor peak SPAP >60 mm Hg was predictive of occurrence of AS-related events or aortic valve replacement (all p > 0.20). In contrast, baseline AS severity was an important prognostic factor (all p < 0.01). In this observational study including 148 patients with asymptomatic AS, we confirmed and extended the importance of exercise testing for unveiling functional limitation. More importantly, neither the increase in MPG nor in SPAP at peak exercise was predictive of outcome. Our results do not support the use of these parameters in risk-stratification and clinical management of asymptomatic AS patients. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Size-independent peak shift between normal and upconversion ...

    Indian Academy of Sciences (India)

    2014-02-12

    Feb 12, 2014 ... In this article, we report size-dependent measurement of the shift in peak of upconversion photoluminescence spectra compared to that of normal photoluminescence using a 800 nm femtosecond laser and its second harmonic. It has been shown that the upconversion photoluminescence is always ...

  8. Ionoacoustic characterization of the proton Bragg peak with submillimeter accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Assmann, W., E-mail: walter.assmann@lmu.de; Reinhardt, S.; Lehrack, S.; Edlich, A.; Thirolf, P. G.; Parodi, K. [Department for Medical Physics, Ludwig-Maximilians-Universität München, Am Coulombwall 1, Garching 85748 (Germany); Kellnberger, S.; Omar, M.; Ntziachristos, V. [Institute for Biological and Medical Imaging, Technische Universität München and Helmholtz Zentrum München, Ingolstädter Landstrasse 1, Neuherberg 85764 (Germany); Moser, M.; Dollinger, G. [Institute for Applied Physics and Measurement Technology, Universität der Bundeswehr, Werner-Heisenberg-Weg 39, Neubiberg 85577 (Germany)

    2015-02-15

    Purpose: Range verification in ion beam therapy relies to date on nuclear imaging techniques which require complex and costly detector systems. A different approach is the detection of thermoacoustic signals that are generated due to localized energy loss of ion beams in tissue (ionoacoustics). Aim of this work was to study experimentally the achievable position resolution of ionoacoustics under idealized conditions using high frequency ultrasonic transducers and a specifically selected probing beam. Methods: A water phantom was irradiated by a pulsed 20 MeV proton beam with varying pulse intensity and length. The acoustic signal of single proton pulses was measured by different PZT-based ultrasound detectors (3.5 and 10 MHz central frequencies). The proton dose distribution in water was calculated by Geant4 and used as input for simulation of the generated acoustic wave by the matlab toolbox k-WAVE. Results: In measurements from this study, a clear signal of the Bragg peak was observed for an energy deposition as low as 10{sup 12} eV. The signal amplitude showed a linear increase with particle number per pulse and thus, dose. Bragg peak position measurements were reproducible within ±30 μm and agreed with Geant4 simulations to better than 100 μm. The ionoacoustic signal pattern allowed for a detailed analysis of the Bragg peak and could be well reproduced by k-WAVE simulations. Conclusions: The authors have studied the ionoacoustic signal of the Bragg peak in experiments using a 20 MeV proton beam with its correspondingly localized energy deposition, demonstrating submillimeter position resolution and providing a deep insight in the correlation between the acoustic signal and Bragg peak shape. These results, together with earlier experiments and new simulations (including the results in this study) at higher energies, suggest ionoacoustics as a technique for range verification in particle therapy at locations, where the tumor can be localized by ultrasound

  9. PolyaPeak: Detecting Transcription Factor Binding Sites from ChIP-seq Using Peak Shape Information

    Science.gov (United States)

    Wu, Hao; Ji, Hongkai

    2014-01-01

    ChIP-seq is a powerful technology for detecting genomic regions where a protein of interest interacts with DNA. ChIP-seq data for mapping transcription factor binding sites (TFBSs) have a characteristic pattern: around each binding site, sequence reads aligned to the forward and reverse strands of the reference genome form two separate peaks shifted away from each other, and the true binding site is located in between these two peaks. While it has been shown previously that the accuracy and resolution of binding site detection can be improved by modeling the pattern, efficient methods are unavailable to fully utilize that information in TFBS detection procedure. We present PolyaPeak, a new method to improve TFBS detection by incorporating the peak shape information. PolyaPeak describes peak shapes using a flexible Pólya model. The shapes are automatically learnt from the data using Minorization-Maximization (MM) algorithm, then integrated with the read count information via a hierarchical model to distinguish true binding sites from background noises. Extensive real data analyses show that PolyaPeak is capable of robustly improving TFBS detection compared with existing methods. An R package is freely available. PMID:24608116

  10. Flood frequency analysis for nonstationary annual peak records in an urban drainage basin

    Science.gov (United States)

    Villarini, Gabriele; Smith, James A.; Serinaldi, Francesco; Bales, Jerad; Bates, Paul D.; Krajewski, Witold F.

    2009-08-01

    Flood frequency analysis in urban watersheds is complicated by nonstationarities of annual peak records associated with land use change and evolving urban stormwater infrastructure. In this study, a framework for flood frequency analysis is developed based on the Generalized Additive Models for Location, Scale and Shape parameters (GAMLSS), a tool for modeling time series under nonstationary conditions. GAMLSS is applied to annual maximum peak discharge records for Little Sugar Creek, a highly urbanized watershed which drains the urban core of Charlotte, North Carolina. It is shown that GAMLSS is able to describe the variability in the mean and variance of the annual maximum peak discharge by modeling the parameters of the selected parametric distribution as a smooth function of time via cubic splines. Flood frequency analyses for Little Sugar Creek (at a drainage area of 110km) show that the maximum flow with a 0.01-annual probability (corresponding to 100-year flood peak under stationary conditions) over the 83-year record has ranged from a minimum unit discharge of 2.1mskm to a maximum of 5.1mskm. An alternative characterization can be made by examining the estimated return interval of the peak discharge that would have an annual exceedance probability of 0.01 under the assumption of stationarity (3.2mskm). Under nonstationary conditions, alternative definitions of return period should be adapted. Under the GAMLSS model, the return interval of an annual peak discharge of 3.2mskm ranges from a maximum value of more than 5000 years in 1957 to a minimum value of almost 8 years for the present time (2007). The GAMLSS framework is also used to examine the links between population trends and flood frequency, as well as trends in annual maximum rainfall. These analyses are used to examine evolving flood frequency over future decades.

  11. Value-based performance measures for Hanford Tank Waste Remedition System (TWRS) Program

    International Nuclear Information System (INIS)

    Keeney, R.L.; von Winterfeldt, D.

    1996-01-01

    The Tank Waste Remediation Systems (TWRS) Program is responsible for the safe storage, retrieval, treatment, and preparation for disposal of high-level waste currently stored in underground storage tanks at the Hanford site in Richland. The TWRS program has adopted a logical approach to decision making that is based on systems engineering and decision analysis (Westinghouse Hanford Company, 1995). This approach involves the explicit consideration of stakeholder values and an evaluation of the TWRS alternatives in terms of these values. Such evaluations need to be consistent across decisions. Thus, an effort was undertaken to develop a consistent, quantifiable set of measures that can be used by TVVRS to assess alternatives against the stakeholder values. The measures developed also met two additional requirements: 1) the number of measure should be relatively small; and 2) performance with respect to the measures should be relatively easy to estimate

  12. Conductivity peak, relaxation dynamics, and superconducting gap of YBa2Cu3O7 studied by terahertz and femtosecond optical spectroscopies

    International Nuclear Information System (INIS)

    Frenkel, A.; Gao, F.; Liu, Y.; Whitaker, J.F.; Uher, C.; Hou, S.Y.; Phillips, J.M.

    1996-01-01

    Recent measurements at microwave, terahertz (THz), and infrared frequencies have revealed a peak in σ 1 below T c . Based on our THz measurements, which were performed on high quality, single crystal films of YBCO (900 and 500 A), we have found that σ 1 features a peak which increases in amplitude and shifts to lower temperatures as frequency changes from 1.2 to 0.4 THz. Although the quasiparticle relaxation time extracted from these results using the two-fluid Drude model exhibits an enhancement below T c , the analysis may not be adequate to account for the strong frequency dependence of the conductivity peak by the competition between the drop in scattering rate and the decreasing normal fluid density with temperature. On the contrary, we were able to account for the frequency dependent σ 1 by fitting with Mattis-Bardeen theory (modified to include scattering) using a slower average rate of increase of the anisotropic gap than for the BCS case as temperature decreases below T c . This is consistent with the higher normal fluid density (higher than Gorter-Casimir values) from the two-fluid model interpretation of our THz results. Thus, we have found evidence of BCS coherence factors in a high-T c superconductor with a slower than BCS gap increase below T c . We have discussed the role of coherence factors to account for the presence of the conductivity peak and the absence of the peak in NMR relaxation rate. Furthermore, we have presented a model for the quasiparticle relaxation time measured by the femtosecond pump-probe spectroscopy. This model allowed us to find a fit to the temperature-dependent energy gap function which is also consistent with the slower gap increase below T c

  13. A novel noninvasive method for measuring fatigability of the quadriceps muscle in noncooperating healthy subjects

    DEFF Research Database (Denmark)

    Poulsen, Jesper Brøndum; Rose, Martin Høyer; Møller, Kirsten

    2015-01-01

    days, nonvoluntary isometric contractions (twitch and tetanic) of the quadriceps femoris muscle evoked by transcutaneous electrical muscle stimulation were recorded in twelve healthy adults. For tetanic contractions, the Fatigue Index (ratio of peak torque values) and the slope of the regression line...... of peak torque values were primary outcome measures. For twitch contractions, maximum peak torque and rise time were calculated. Relative (intraclass correlation, ICC3.1) and absolute (standard error of measurement, SEM) reliability were assessed and minimum detectable change was calculated using a 95...... fatigability of the quadriceps muscle produces reliable results in healthy subjects and may provide valuable data on quantitative changes in muscle working capacity and treatment effects in patients who are incapable of producing voluntary muscle contractions....

  14. Environmental Dependence of Artifact CD Peaks of Chiral Schiff Base 3d-4f Complexes in Soft Mater PMMA Matrix

    Directory of Open Access Journals (Sweden)

    Yu Okamoto

    2011-10-01

    Full Text Available Four chiral Schiff base binuclear 3d-4f complexes (NdNi, NdCu, GdNi, and GdCu have been prepared and characterized by means of electronic and CD spectra, IR spectra, magnetic measurements, and X-ray crystallography (NdNi. A so-called artifact peak of solid state CD spectra, which was characteristic of oriented molecules without free molecular rotation, appeared at about 470 nm. Magnetic data of the complexes in the solid state (powder and in PMMA cast films or solutions indicated that only GdCu preserved molecular structures in various matrixes of soft maters. For the first time, we have used the changes of intensity of artifact CD peaks to detect properties of environmental (media solid state (KBr pellets, PMMA cast films, concentration dependence of PMMA in acetone solutions, and pure acetone solution for chiral 3d-4f complexes (GdCu. Rigid matrix keeping anisotropic orientation exhibited a decrease in the intensity of the artifact CD peak toward negative values. The present results suggest that solid state artifact CD peaks can be affected by environmental viscosity of a soft mater matrix.

  15. Probabilistic peak detection in CE-LIF for STR DNA typing.

    Science.gov (United States)

    Woldegebriel, Michael; van Asten, Arian; Kloosterman, Ate; Vivó-Truyols, Gabriel

    2017-07-01

    In this work, we present a novel probabilistic peak detection algorithm based on a Bayesian framework for forensic DNA analysis. The proposed method aims at an exhaustive use of raw electropherogram data from a laser-induced fluorescence multi-CE system. As the raw data are informative up to a single data point, the conventional threshold-based approaches discard relevant forensic information early in the data analysis pipeline. Our proposed method assigns a posterior probability reflecting the data point's relevance with respect to peak detection criteria. Peaks of low intensity generated from a truly existing allele can thus constitute evidential value instead of fully discarding them and contemplating a potential allele drop-out. This way of working utilizes the information available within each individual data point and thus avoids making early (binary) decisions on the data analysis that can lead to error propagation. The proposed method was tested and compared to the application of a set threshold as is current practice in forensic STR DNA profiling. The new method was found to yield a significant improvement in the number of alleles identified, regardless of the peak heights and deviation from Gaussian shape. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Measurement of the G-value for 1. 5 keV X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Freyer, J.P.; Schillaci, M.E.; Raju, M.R. (Los Alamos National Lab., NM (USA))

    1989-12-01

    Using a ferrous sulfate solution modified by the addition of benzoic acid, the authors measured relative G-values for Al{sub k} characteristic X-rays (1.5keV), {sup 238}Pu {alpha}-particles (3.7MeV), {sup 60}Co (1.17 MeV) and {sup 137}Cs (0.66 MeV){gamma}-rays. Relative ferrous-to-ferric conversions as a function of dose were similar for the two {gamma}-ray energies, yielding G-values of 1.62 and 1.59 {mu}mol J{sup -1} for the {sup 60}Co and {sup 137}Cs radiations. The {alpha}-particle G-value was 0.52 {mu}mol J{sup -1}, or 31% of that for {sup 60}Co {gamma}-rays. The Al{sub k} X-rays had a G-value of 0.92 {mu}mol J{sup -1} or 57% of that of the {sup 60}Co radiation. This G-value for 1.5 keV X-rays is within 20% of values predicted by current theories, and theoretical values are within the error range of the authors' measurements. (author).

  17. Statistics of Microstructure, Peak Stress and Interface Damage in Fiber Reinforced Composites

    DEFF Research Database (Denmark)

    Kushch, Volodymyr I.; Shmegera, Sergii V.; Mishnaevsky, Leon

    2009-01-01

    This paper addresses an effect of the fiber arrangement and interactions on the peak interface stress statistics in a fiber reinforced composite material (FRC). The method we apply combines the multipole expansion technique with the representative unit cell model of composite bulk, which is able...... to simulate both the uniform and clustered random fiber arrangements. By averaging over a number of numerical tests, the empirical probability functions have been obtained for the nearest neighbor distance and the peak interface stress. It is shown that the considered statistical parameters are rather...... sensitive to the fiber arrangement, particularly cluster formation. An explicit correspondence between them has been established and an analytical formula linking the microstructure and peak stress statistics in FRCs has been suggested. Application of the statistical theory of extreme values to the local...

  18. Crystallite size and lattice distortion of human dental enamel estimated from the integral width of x-ray diffraction peak profile

    International Nuclear Information System (INIS)

    Maruyama, Fumiaki; Sakae, Toshiro

    2000-01-01

    Crystallite size and lattice distortion of human dental enamel were estimated by peak profile analysis using x-ray diffraction pattern. Firstly, noises were removed from x-ray diffraction pattern, and deconvolution of overlapping peaks and determination of baseline level were carried out. Then, the instrumental peak broadening and effect of overlapping Kα1 and Kα2 were eliminated to obtain pure peak profile using the Stokes's Fourier method. The integral width method was applied for estimation of crystallite size and 'upper-limit of distortion', assuming the peak profile as Cauchy function. The estimated crystallite size and distortion were ca. 210 A and ca. 0.4% in the a-axis direction and ca. 550 A and ca. 0.7% in the c-axis direction, respectively. The crystallite size value along the a-axis was almost the same to the previously reported values, but the value for along the c-axis was nearly half of the reported values. The crystallite size in this study means the size of coherent domain in contrast to the size of particle which may contain several domains in the case of enamel crystals. The results suggest that human enamel crystals grow in their size along the c-axis by multiplication, fusion of crystallites. It was notable that the distortion value was larger in the c-axis direction. The phenomenon may partly be due to the high carbonate ion content of enamel crystals and partly due to crystal growth mechanism. (author)

  19. Peak capacity and peak capacity per unit time in capillary and microchip zone electrophoresis.

    Science.gov (United States)

    Foley, Joe P; Blackney, Donna M; Ennis, Erin J

    2017-11-10

    The origins of the peak capacity concept are described and the important contributions to the development of that concept in chromatography and electrophoresis are reviewed. Whereas numerous quantitative expressions have been reported for one- and two-dimensional separations, most are focused on chromatographic separations and few, if any, quantitative unbiased expressions have been developed for capillary or microchip zone electrophoresis. Making the common assumption that longitudinal diffusion is the predominant source of zone broadening in capillary electrophoresis, analytical expressions for the peak capacity are derived, first in terms of migration time, diffusion coefficient, migration distance, and desired resolution, and then in terms of the remaining underlying fundamental parameters (electric field, electroosmotic and electrophoretic mobilities) that determine the migration time. The latter expressions clearly illustrate the direct square root dependence of peak capacity on electric field and migration distance and the inverse square root dependence on solute diffusion coefficient. Conditions that result in a high peak capacity will result in a low peak capacity per unit time and vice-versa. For a given symmetrical range of relative electrophoretic mobilities for co- and counter-electroosmotic species (cations and anions), the peak capacity increases with the square root of the electric field even as the temporal window narrows considerably, resulting in a significant reduction in analysis time. Over a broad relative electrophoretic mobility interval [-0.9, 0.9], an approximately two-fold greater amount of peak capacity can be generated for counter-electroosmotic species although it takes about five-fold longer to do so, consistent with the well-known bias in migration time and resolving power for co- and counter-electroosmotic species. The optimum lower bound of the relative electrophoretic mobility interval [μ r,Z , μ r,A ] that provides the maximum

  20. Fock-state view of weak-value measurements and implementation with photons and atomic ensembles

    International Nuclear Information System (INIS)

    Simon, Christoph; Polzik, Eugene S.

    2011-01-01

    Weak measurements in combination with postselection can give rise to a striking amplification effect (related to a large ''weak value''). We show that this effect can be understood by viewing the initial state of the pointer as the ground state of a fictional harmonic oscillator. This perspective clarifies the relationship between the weak-value regime and other measurement techniques and inspires a proposal to implement fully quantum weak-value measurements combining photons and atomic ensembles.

  1. FAIR VALUE MEASUREMENT IN AGRICULTURE AND THE POTENTIAL TO MISLEAD

    Directory of Open Access Journals (Sweden)

    VLADU ALINA BEATTRICE

    2013-08-01

    Full Text Available Applying fair value measurement to tangible and intangible assets in agriculture cannot be risk free. Twofoldreasons can be brought into attention for the above statement: fair value estimation and the specific of agriculturefield. The purpose of this discussion paper is to underline potential creative accounting demarches that can appear inthis context. The paper concludes based on the discussions approached in the literature. Further avenues of researchare discussed.

  2. Shared Values?: Measuring Value Differences Between Civilians and Soldiers

    National Research Council Canada - National Science Library

    Efflandt, Scott

    1998-01-01

    .... In response to this many within and outside of the military have attributed these problems to the absence of personal values among new service members that are congruent with the military's core values...

  3. Low diagnostic value of respiratory impedance measurements in children

    NARCIS (Netherlands)

    Cuijpers, CEJ; Wesseling, GJ; Kessels, AGH; Swaen, GMH; Mertens, PLJM; deKok, ME; Broer, J; Sturmans, F; Wouters, EFM

    The aim of this study was to determine whether impedance values in children with various chronic respiratory complaints differed from those observed in symptom-free children. Respiratory impedance was measured using the forced oscillation technique in 1,776 Dutch children aged 6-12 yrs. In addition

  4. Methods for the analysis of the overlapped peaks in analytical gamma-spectrometry

    International Nuclear Information System (INIS)

    Sterlinski, S.; Wasek, M.

    1989-01-01

    A new simple method for the quantitative analysis of the doublet peaks in Ge(Li) or HPGe gamma-spectrometry is presented. No assumptions on the shape of the peaks in gamma-ray spectra being measured are required. Special feature of the method proposed is its usefulness for the analysis of closed doublets. 7 refs., 6 figs. (author)

  5. Comparison of early myocardial technetium-99m pyrophosphate uptake to early peaking of creatine kinase and creatine kinase-MB as indicators of early reperfusion in acute myocardial infarction

    International Nuclear Information System (INIS)

    Kondo, M.; Yuzuki, Y.; Arai, H.; Shimizu, K.; Morikawa, M.; Shimono, Y.

    1987-01-01

    The value of technetium-99m pyrophosphate (Tc-99m-PYP) scintigraphy as an indicator of reperfusion 2.8 to 8 hours after the onset of symptoms of acute myocardial infarction was compared with the value of early peak creatine kinase (CK) and CK-MB release within 16 hours after the onset of symptoms. In 29 patients who received thrombolytic therapy, recanalization was seen (group 1) and in 7 it was not (group 2). In 23 patients (79%) in group 1 scintigraphic findings were positive and in all 7 in group 2 they were negative. In 15 patients (52%) in group 1 and 1 patient (14%) in group 2, CK reached its peak level within 16 hours. In 20 patients (69%) in group 1 and 3 (43%) in group 2 the CK-MB level reached a peak within 16 hours. The sensitivity, specificity and predictive accuracy of positive results of early Tc-99m-PYP scintigraphy in predicting the reperfusion were 79%, 100% and 83%. These values are significantly higher than or similar to those of early peaking of CK and CK-MB release. In contrast to measurements of enzyme release, reperfusion data for Tc-99m-PYP scintigraphy are available immediately after thrombolytic therapy. Therefore, early Tc-99m-PYP scintigraphy (3 to 8 hours after onset of symptoms) is valuable as a noninvasive technique for early diagnosis of reperfusion

  6. Carbon-14 dating of tree rings for tritium measurement

    International Nuclear Information System (INIS)

    Yamada, Y.; Yasuike, K.; Kiriyama, N.; Komura, K.; Ueno, K.

    1998-01-01

    The carbon-14 concentration in tree-ring cellulose of an 80-year-old pine tree which has been used for tritium measurement was measured during the 1941-1987 period. This was done to determine the formation year of each tree ring in order to study the pathway of tritium uptake into the tree rings. In the 1941 to 1953 period, the δ 14 C value remained slightly lower than 0 per mille. It began to increase from 1954 to a small broad peak of 250 per mille between 1959 and 1961, followed by rapid increase to the highest value of approximately 800 per mille in 1964. Since 1964, it had been diminishing year by year to reach a level of 190 per mille in 1987. The two peak years coincided with those in the known carbon-14 patterns in tree rings. However, there existed a difference in the amplitude of the δ 14 C values during the period of 1963-1967. (author)

  7. Characteristics of peaks of inhalation exposure to organic solvents

    NARCIS (Netherlands)

    Preller, L.; Burstyn, I.; Pater, N. de; Kromhout, H.

    2004-01-01

    Objectives: To determine which exposure metrics are sufficient to characterize 'peak' inhalation exposure to organic solvents (OS) during spraying operations. Methods: Personal exposure measurements (n = 27; duration 5-159 min) were collected during application of paints, primers, resins and glues

  8. Peak expiratory flow rate in healthy children aged 6-17 years

    DEFF Research Database (Denmark)

    Høst, A; Høst, A H; Ibsen, T

    1994-01-01

    Peak expiratory flow rate (PEFR) was measured in a cross-sectional study in 861 healthy Danish schoolchildren aged 6-17 years using a Mini Wright peak flowmeter. We found a strong correlation between PEFR and height, age and sex. The results were comparable with those from previous studies using...... a Wright peak flowmeter. The equation for prediction of PEFR in boys was calculated as (3.8 x height) + (10.6 x age) - 313.2 (p age) - 143.9 (p ... coefficient in this large sample. Among healthy children without previous asthma, earlier episodes of recurrent wheezing were reported in 8.8% and a significantly lower PEFR was found in this group....

  9. A step-by-step plan to manage and measure adding value by FM/CREM

    DEFF Research Database (Denmark)

    van der Voordt, Theo; Jensen, Per Anker; Hoendervanger, Jan Gerard

    2016-01-01

    Purpose To present a new Value Adding Management model in order to support decision makers in identifying appropriate interventions to add value to the organisation, to manage its implementation, and to measure the output and outcomes. Theory The paper builds on value adding management theories...... different European countries present a state of the art of theory and research on 12 value parameters, how to manage and measure each value, and to discuss the costs and benefits of typical FM and CREM interventions to enhance satisfaction, image, culture, health and safety, productivity, adaptability...... and models including the triplet input-throughput-output, a distinction between output, outcome and added value, the Plan-Do-Act-Check cycle, change management and performance measurement. Design/methodology/approach Literature review and a cross-chapter analysis of a forthcoming book, where authors from...

  10. Peak power, force, and velocity during jump squats in professional rugby players.

    Science.gov (United States)

    Turner, Anthony P; Unholz, Cedric N; Potts, Neill; Coleman, Simon G S

    2012-06-01

    Training at the optimal load for peak power output (PPO) has been proposed as a method for enhancing power output, although others argue that the force, velocity, and PPO are of interest across the full range of loads. The aim of this study was to examine the influence of load on PPO, peak barbell velocity (BV), and peak vertical ground reaction force (VGRF) during the jump squat (JS) in a group of professional rugby players. Eleven male professional rugby players (age, 26 ± 3 years; height, 1.83 ± 6.12 m; mass, 97.3 ± 11.6 kg) performed loaded JS at loads of 20-100% of 1 repetition maximum (1RM) JS. A force plate and linear position transducer, with a mechanical braking unit, were used to measure PPO, VGRF, and BV. Load had very large significant effects on PPO (p < 0.001, partial η² = 0.915); peak VGRF (p < 0.001, partial η² = 0.854); and peak BV (p < 0.001, partial η² = 0.973). The PPO and peak BV were the highest at 20% 1RM, though PPO was not significantly greater than that at 30% 1RM. The peak VGRF was significantly greater at 1RM than all other loads, with no significant difference between 20 and 60% 1RM. In resistance trained professional rugby players, the optimal load for eliciting PPO during the loaded JS in the range measured occurs at 20% 1RM JS, with decreases in PPO and BV, and increases in VGRF, as the load is increased, although greater PPO likely occurs without any additional load.

  11. Middle cerebral artery peak systolic velocity to predict fetal hemoglobin levels in twin anemia-polycythemia sequence.

    Science.gov (United States)

    Slaghekke, F; Pasman, S; Veujoz, M; Middeldorp, J M; Lewi, L; Devlieger, R; Favre, R; Lopriore, E; Oepkes, D

    2015-10-01

    To evaluate the diagnostic accuracy of middle cerebral artery peak systolic velocity (MCA-PSV) Doppler measurements in prediction of hemoglobin levels in twin anemia-polycythemia sequence (TAPS). This study involved a consecutive cohort comprising monochorionic twin pregnancies complicated by TAPS managed at three European fetal medicine centers between 2005 and 2013. The accuracy of MCA-PSV, measured immediately prior to fetal hemoglobin (Hb) measurement by fetal or cord blood sampling, for prediction of anemia and polycythemia was assessed using 2 × 2 tables. A total of 116 measurements (74 recorded in donors and 42 in recipients) from 43 twin pregnancies complicated by TAPS were available for analysis. MCA-PSV multiples of the median (MoM) values correlated well with Hb levels (r = - 0.86; P  5 SD below the mean) in TAPS donors was 94% (95% CI, 85-98%); specificity was 74% (95% CI, 62-83%); positive and negative predictive values were 76% (95% CI, 65-85%) and 94% (95% CI, 83-98%), respectively. The sensitivity of MCA-PSV ≤ 1.0 MoM to predict polycythemia (Hb level > 5 SD above the mean) in TAPS recipients was 97% (95% CI, 87-99%); specificity was 96% (95% CI, 89-99%); positive and negative predictive values were 93% (95% CI, 81-97%) and 99% (95% CI, 93-100%), respectively. MCA-PSV measurement has high diagnostic accuracy for predicting abnormal Hb levels in fetuses with TAPS. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  12. Measuring the value of internal audit in the banking industry

    Directory of Open Access Journals (Sweden)

    Clara-Iulia Zinca (Voiculescu

    2016-09-01

    The results of the study suggest that most organizations use methods that contain mainly quantitative and less qualitative elements. There are differences between banks and other types of organizations in terms of the methods and practices used, but also on the importance showed to measurement of internal audit value. In addition, the findings confirm that there is room for improving the methods and practices used, so that the audit function gains value and credibility.

  13. Diagnóstico não invasivo da anemia fetal pela medida do pico de velocidade sistólica na dopplervelocimetria da artéria cerebral média Noninvasive fetal anemia diagnosis by middle cerebral artery peak systolic velocity waveform measurement

    Directory of Open Access Journals (Sweden)

    Marcos Roberto Taveira

    2004-09-01

    Full Text Available OBJETIVO: avaliar se existe associação entre a medida do pico de velocidade sistólica (PVS na dopplervelocimetria da artéria cerebral média (ACM e a concentração de hemoglobina fetal e determinar a sua capacidade diagnóstica. MÉTODOS: entre janeiro de 2000 e maio de 2003, 44 gestantes isoimunizadas foram submetidas a transfusão intra-uterina. Realizou-se estudo dopplervelocimétrico da ACM antes de cada transfusão fetal, sempre com intervalo inferior a 3 horas, antecedendo o procedimento. O PVS da ACM foi considerado alterado quando seu valor era superior a 1,5 múltiplo da mediana para a respectiva idade gestacional. A concentração de hemoglobina do cordão foi aferida antes de se iniciar a infusão de sangue, realizada no Hemocue® (B-Hemoglobin Photometer Hemocue AB; Angelholm, Sweden. O estudo estatístico foi feito pelo teste do chi2 e também foram calculados os valores de sensibilidade, especificidade, valores preditivos positivo e negativo. RESULTADOS: foram realizados 83 procedimentos, sendo que em 33 a hemoglobina fetal era inferior a 10,0 g/dL. Houve associação significativa entre as variáveis estudadas, pPURPOSE: to assess the correlation between middle cerebral artery peak systolic velocity and umbilical cord blood hemoglobin concentration and to determine its diagnostic value. PATIENTS AND METHODS: a cross-sectional prospective study was performed from January 2000 to May 2003. Forty-four isoimmunized pregnant women underwent a protocol for the identification of fetal hemolysis. When intrauterine transfusions were indicated, the umbilical cord blood hemoglobin concentration was measured at the beginning of the procedure. Each intrauterine transfusion preceded by Doppler velocimetry of the middle cerebral artery was regarded as one case, summing up eighty-three procedures. In all cases, the middle cerebral artery Doppler examinations were performed within the three hours preceding fetal blood sample collection. The

  14. The value of pulmonary vessel CT measuring and calculating of relative ratio

    International Nuclear Information System (INIS)

    Ji Jiansong; Xu Xiaoxiong; Lv Suzhen; Zhao Zhongwei; Wang Zufei; Xu Min; Gong Jianping

    2004-01-01

    Objective: To evaluate value of CT measurement and calculation of vessels of isolate pig lung, by compare with measurement and calculation of resin cast of them. Methods: CT scanned and measured the four isolated pig lung which vessels were full with ABS liquid or self-solidification resin liquid, and calculate the relative ratio of superior/inferior order and vein/artery of same order. After resin cast were made, measure and calculate the same as CT did. Results: Second order of calculation of vein/artery of same order by the two method had statistic difference (P 0.05). Conclusion: CT has high value in calculation of the relative ratio of superior/inferior order

  15. Forest Value Orientations in Australia: An Application of Computer Content Analysis

    Science.gov (United States)

    Webb, Trevor J.; Bengston, David N.; Fan, David P.

    2008-01-01

    This article explores the expression of three forest value orientations that emerged from an analysis of Australian news media discourse about the management of Australian native forests from August 1, 1997 through December 31, 2004. Computer-coded content analysis was used to measure and track the relative importance of commodity, ecological and moral/spiritual/aesthetic forest value orientations. The number of expressions of these forest value orientations followed major events in forest management and policy, with peaks corresponding to finalization of Regional Forest Agreements and conflicts over forest management. Over the time period analyzed, the relative share of commodity value orientation decreased and the shares of the ecological and moral/spiritual/aesthetic value orientations increased. The shifts in forest value orientations highlight the need for native forests to be managed for multiple values and the need for continued monitoring of forest values.

  16. Measuring Value-at-Risk and Expected Shortfall of crude oil portfolio using extreme value theory and vine copula

    Science.gov (United States)

    Yu, Wenhua; Yang, Kun; Wei, Yu; Lei, Likun

    2018-01-01

    Volatilities of crude oil price have important impacts on the steady and sustainable development of world real economy. Thus it is of great academic and practical significance to model and measure the volatility and risk of crude oil markets accurately. This paper aims to measure the Value-at-Risk (VaR) and Expected Shortfall (ES) of a portfolio consists of four crude oil assets by using GARCH-type models, extreme value theory (EVT) and vine copulas. The backtesting results show that the combination of GARCH-type-EVT models and vine copula methods can produce accurate risk measures of the oil portfolio. Mixed R-vine copula is more flexible and superior to other vine copulas. Different GARCH-type models, which can depict the long-memory and/or leverage effect of oil price volatilities, however offer similar marginal distributions of the oil returns.

  17. Impact of energy efficiency measures on the economic value of buildings

    International Nuclear Information System (INIS)

    Popescu, Daniela; Bienert, Sven; Schuetzenhofer, Christian; Boazu, Rodica

    2012-01-01

    Highlights: → Market driven reasons can strengthen implementation of energy policies in buildings. → Methods that quantify the added value due to energy performance are developed. → Recommendations on how they can be incorporated in the financial analysis are presented. → Case studies on some existing condominiums from Romania are analyzed. → The market sensitivity to energy efficiency measures is also in the focus. -- Abstract: A main objective of energy policies is to make all levels of the society, from governments to citizen, interested in increasing the energy efficiency of buildings. One of the most important barriers in implementation of energy policies is that the cost of potential energy savings, typically considered being the only financial benefit, does not sufficiently motivate investments. The target is therefore to identify further possible drivers pushing positive reaction according to energy saving action. The paper discusses whether a market-based instrument, capturing the increase of the economic value of energy efficient buildings, can be also used. Methods that quantify the added value due to energy performance, including recommendations on how they can be incorporated in the financial analysis of investments in weatherization, are developed. By applying the proposed methods, the payback period of investments in energy efficiency measures depends on two factors: potential energy savings and the added value to the property. Case studies on some existing condominiums from Romania are analyzed and provide evidence to the research question. The market sensitivity to energy efficiency measures, the possibility of an intangible added value as well as the impact to financial investment decisions is subsequently in the focus.

  18. Peak expiratory flow rate (PEFR) among Nuclear Fuel Complex (NFC) employees

    International Nuclear Information System (INIS)

    Vijay Rao, J.; Venkaiah, K.; Mohan Rao, N.

    2010-01-01

    At Nuclear Fuel Complex (NFC), employees are exposed to ammonia, hydrofluoric acid, acetone, etc., which are respiratory toxicants and inhalation of these pollutants may produce irritation and obstruction in airways. Due to nature of their occupation, tradesman working in plants are having longer duration of exposure (LDE) and others, such as supervisors, scientific officers, helpers, etc., that occasionally visit plants are having shorter duration of exposure (SDE) to these pollutants. The peak expiratory flow rate (PEFR) is an index to diagnose obstruction in larger airways and this is metered with mini peak flow meter among 835 NFC employees. Using ANOVA test, PEFR value was compared according to age and smoking. The value was compared between LDE and SDE employees according to smoking and duration of employment. The multiple regression equation for prediction of PEFR was developed. Age, smokers and higher duration of LDE employees demonstrated significantly lower PEFR value. In comparison to 10 year duration, 30 and above year duration of employment, LDE employees showed a higher decline in PEFR, that is 95 L (17.6%) and in SDE employees, that is 41L (7.8%). This may be due to longer duration of employment of LD employees smoking prevention and follow up study is suggested. (author)

  19. Valuing Informal Care Experience: Does Choice of Measure Matter?

    Science.gov (United States)

    Mentzakis, Emmanouil; McNamee, Paul; Ryan, Mandy; Sutton, Matthew

    2012-01-01

    Well-being equations are often estimated to generate monetary values for non-marketed activities. In such studies, utility is often approximated by either life satisfaction or General Health Questionnaire scores. We estimate and compare monetary valuations of informal care for the first time in the UK employing both measures, using longitudinal…

  20. Against Journal Articles for Measuring Value in University Output

    Science.gov (United States)

    Mbali, C.

    2010-01-01

    The following lines of arguments against the metrics of journal articles is developed: (1) Textual output should no longer be main valued output; (2) Digitalization enables other ways of advancing knowledge; (3) Measures by journal article favours the disciplines of Natural Science and Engineering (NSE) and moulds other disciplines of Social…

  1. Multiscale peak detection in wavelet space.

    Science.gov (United States)

    Zhang, Zhi-Min; Tong, Xia; Peng, Ying; Ma, Pan; Zhang, Ming-Jin; Lu, Hong-Mei; Chen, Xiao-Qing; Liang, Yi-Zeng

    2015-12-07

    Accurate peak detection is essential for analyzing high-throughput datasets generated by analytical instruments. Derivatives with noise reduction and matched filtration are frequently used, but they are sensitive to baseline variations, random noise and deviations in the peak shape. A continuous wavelet transform (CWT)-based method is more practical and popular in this situation, which can increase the accuracy and reliability by identifying peaks across scales in wavelet space and implicitly removing noise as well as the baseline. However, its computational load is relatively high and the estimated features of peaks may not be accurate in the case of peaks that are overlapping, dense or weak. In this study, we present multi-scale peak detection (MSPD) by taking full advantage of additional information in wavelet space including ridges, valleys, and zero-crossings. It can achieve a high accuracy by thresholding each detected peak with the maximum of its ridge. It has been comprehensively evaluated with MALDI-TOF spectra in proteomics, the CAMDA 2006 SELDI dataset as well as the Romanian database of Raman spectra, which is particularly suitable for detecting peaks in high-throughput analytical signals. Receiver operating characteristic (ROC) curves show that MSPD can detect more true peaks while keeping the false discovery rate lower than MassSpecWavelet and MALDIquant methods. Superior results in Raman spectra suggest that MSPD seems to be a more universal method for peak detection. MSPD has been designed and implemented efficiently in Python and Cython. It is available as an open source package at .

  2. Regression analysis of MCS Intensity and peak ground motion data in Italy

    Science.gov (United States)

    Faenza, L.; Michelini, A.

    2009-04-01

    Intensity scales are historically important because no instrumentation is necessary, and useful measurements of earthquake shaking can be made by an unequipped observer. The use of macroseismics data are essential for the revision of historical seismicity and of great importance for seismic hazard assessment of vulnerable areas. The procedure ShakeMap (Wald et al., Earthquake Spectra., 15, 1999) provides instrumentally based estimates of intensity maps. In Italy, intensities have been hitherto reported through the use of the MCS (Mercalli, Cancani Sieberg) intensity scale. The DBMI2004 (and the most recent DBMI08) report intensities for earthquakes in Italy that date back to Roman age. In order to exploit fully the potential of such a long intensity catalogue for past large events and with the aim of presenting ShakeMaps using an intensity scale consistent with that of the past, we have ri-calibrated the relationships between MCS intensity and observed peak ground motion (PGM) values in terms of both peak-ground acceleration and peak-ground velocities. To this end, we have used the two most updataed and complete dataset available for Italy - the strong motion Itaca database and the DBMI08 macroseismic database. In this work we have first assembled a data set consisting of PGM-intensity pairs and we have then determined the most suitable regressions parameters. Many tests have been made to quantify the accuracy and robustness of the results. The new instrumental intensity scale is going to be adopted for mapping the level of shaking resulting from earthquakes in Italy replacing the instrumental Modified Mercalli scale currently in use (Michelini et al., SRL, 79, 2008) and to determine shakemaps for historical events.

  3. Automated asteroseismic peak detections

    DEFF Research Database (Denmark)

    de Montellano, Andres Garcia Saravia Ortiz; Hekker, S.; Themessl, N.

    2018-01-01

    Space observatories such as Kepler have provided data that can potentially revolutionize our understanding of stars. Through detailed asteroseismic analyses we are capable of determining fundamental stellar parameters and reveal the stellar internal structure with unprecedented accuracy. However......, such detailed analyses, known as peak bagging, have so far been obtained for only a small percentage of the observed stars while most of the scientific potential of the available data remains unexplored. One of the major challenges in peak bagging is identifying how many solar-like oscillation modes are visible...... of detected oscillation modes. The algorithm presented here opens the possibility for detailed and automated peak bagging of the thousands of solar-like oscillators observed by Kepler....

  4. Environmental impacts of public transport. Why peak-period travellers cause a greater environmental burden than off-peak travellers

    International Nuclear Information System (INIS)

    Rietveld, P.

    2002-01-01

    Given the difference between peak and off-peak occupancy rates in public transport, emissions per traveller kilometre are lower in the peak than in the off-peak period, whereas the opposite pattern is observed for cars. It is argued that it is much more fruitful to analyse environmental effects in marginal terms. This calls for a careful analysis of capacity management policies of public transport suppliers that are facing increased demand during both peak and off-peak periods. A detailed analysis of capacity management by the Netherlands Railways (NS) revealed that off-peak capacity supply is mainly dictated by the demand levels during the peak period. The analysis included the effects of increased frequency and increased vehicle size on environmental impacts, while environmental economies of vehicle size were also taken into account. The main conclusion is that the marginal environmental burden during the peak hours is much higher than is usually thought, whereas it is almost zero during the off-peak period. This implies a pattern that is the precise opposite of the average environmental burden. Thus, an analysis of environmental effects of public transport based on average performance would yield misleading conclusions [nl

  5. Bragg peak proton beam treatment of arteriovenous malformations of the brain

    International Nuclear Information System (INIS)

    Kjellberg, R.N.; Poletti, C.E.; Roberson, G.H.; Adams, R.D.

    1978-01-01

    This report describes 27 patients treated for arteriovenous malformations of the brain by the Bragg Peak proton beam method during the past 12 years. The authors are led to a measure of confidence that Bragg Peak proton therapy can be provided without lethal risk attributed to the procedure. In 21 patients no neurological change has occurred, two patients experienced neurological improvement and four have developed new neurological abnormalities considered complications of the therapy. (Auth.)

  6. Study of V-OTDR stability for dynamic strain measurement in piezoelectric vibration

    Science.gov (United States)

    Ren, Meiqi; Lu, Ping; Chen, Liang; Bao, Xiaoyi

    2016-09-01

    In a phase-sensitive optical-time domain reflectometry (Φ-OTDR) system, the challenge for dynamic strain measurement lies in large intensity fluctuations from trace to trace. The intensity fluctuation caused by stochastic characteristics of Rayleigh backscattering sets detection limit for the minimum strength of vibration measurement and causes the large measurement uncertainty. Thus, a trace-to-trace correlation coefficient is introduced to quantify intensity fluctuation of Φ-OTDR traces and stability of the sensor system theoretically and experimentally. A novel approach of measuring dynamic strain induced by various driving voltages of lead zirconate titanate (PZT) in Φ-OTDR is also demonstrated. Piezoelectric vibration signals are evaluated through analyzing peak values of fast Fourier transform spectra at the fundamental frequency and high-order harmonics based on Bessel functions. High trace-to-trace correlation coefficients varying from 0.824 to 0.967 among 100 measurements are obtained in experimental results, showing the good stability of our sensor system, as well as small uncertainty of measured peak values.

  7. Acquisition of peak responding: what is learned?

    Science.gov (United States)

    Balci, Fuat; Gallistel, Charles R; Allen, Brian D; Frank, Krystal M; Gibson, Jacqueline M; Brunner, Daniela

    2009-01-01

    We investigated how the common measures of timing performance behaved in the course of training on the peak procedure in C3H mice. Following fixed interval (FI) pre-training, mice received 16 days of training in the peak procedure. The peak time and spread were derived from the average response rates while the start and stop times and their relative variability were derived from a single-trial analysis. Temporal precision (response spread) appeared to improve in the course of training. This apparent improvement in precision was, however, an averaging artifact; it was mediated by the staggered appearance of timed stops, rather than by the delayed occurrence of start times. Trial-by-trial analysis of the stop times for individual subjects revealed that stops appeared abruptly after three to five sessions and their timing did not change as training was prolonged. Start times and the precision of start and stop times were generally stable throughout training. Our results show that subjects do not gradually learn to time their start or stop of responding. Instead, they learn the duration of the FI, with robust temporal control over the start of the response; the control over the stop of response appears abruptly later.

  8. Hourly peak concentration measuring the PM2.5-mortality association: Results from six cities in the Pearl River Delta study

    Science.gov (United States)

    Lin, Hualiang; Ratnapradipa, Kendra; Wang, Xiaojie; Zhang, Yonghui; Xu, Yanjun; Yao, Zhenjiang; Dong, Guanghui; Liu, Tao; Clark, Jessica; Dick, Rebecca; Xiao, Jianpeng; Zeng, Weilin; Li, Xing; Qian, Zhengmin (Min); Ma, Wenjun

    2017-07-01

    Compared with daily mean concentration of air pollution, hourly peak concentration may be more directly relevant to the acute health effects due to the high concentration levels, however, few have analyzed the acute mortality effects of hourly peak levels of air pollution. We examined the associations of hourly peak concentration of fine particulate matter air pollution (PM2.5) with mortality in six cities in Pearl River Delta, China. We used generalized additive Poisson models to examine the associations with adjustment for potential confounders in each city. We further applied random-effects meta-analyses to estimate the regional overall effects. We further estimated the mortality burden attributable to hourly peak and daily mean PM2.5. We observed significant associations between hourly peak PM2.5 and mortality. Each 10 μg/m3 increase in 4-day averaged (lag03) hourly peak PM2.5 corresponded to a 0.9% [95% confidence interval (CI): 0.7%, 1.1%] increase in total mortality, 1.2% (95% CI: 1.0%, 1.5%) in cardiovascular mortality, and 0.7% (95% CI: 0.2%, 1.1%) in respiratory mortality. We observed a greater mortality burden using hourly peak PM2.5 than daily mean PM2.5, with an estimated 12915 (95% CI: 9922, 15949) premature deaths attributable to hourly peak PM2.5, and 7951 (95% CI: 5067, 10890) to daily mean PM2.5 in the Pearl River Delta (PRD) region during the study period. This study suggests that hourly peak PM2.5 might be one important risk factor of mortality in PRD region of China; the finding provides important information for future air pollution management and epidemiological studies.

  9. Measurement of the total solar energy transmittance (g-value) for conventional glazings

    DEFF Research Database (Denmark)

    Duer, Karsten

    1998-01-01

    Three different glazings have been investigated in the Danish experimental setup METSET. (A device for calorimetric measurement of total solar energy transmittance - g-value).The purpose of the measurements is to increase the confidence in the calorimetric measurements. This is done by comparison...

  10. Cranial Indicators Identified for Peak Incidence of Otitis Media.

    Science.gov (United States)

    Pagano, Anthony S; Wang, Eugene; Yuan, Derek; Fischer, Daniel; Bluestone, Charles; Marquez, Samuel; Laitman, Jeffrey

    2017-10-01

    Acute otitis media (AOM) is one of the most common pediatric conditions worldwide. Peak age of occurrence for AOM has been identified within the first postnatal year and it remains frequent until approximately six postnatal years. Morphological differences between adults and infants in the cartilaginous Eustachian tube (CET) and associated structures may be responsible for development of this disease yet few have investigated normal growth trajectories. We tested hypotheses on coincidence of skeletal growth changes and known ages of peak AOM occurrence. Growth was divided into five dental eruption stages ranging from edentulous neonates (Stage 1) to adults with erupted third maxillary molars (Stage 5). A total of 32 three-dimensional landmarks were used and Generalized Procrustes Analysis was performed. Next, we performed principal components analysis and calculated univariate measures. It was found that growth change in Stage 1 was the most rapid and comprised the largest amount of overall growth in upper respiratory tract proportions (where time is represented by the natural logarithmic transformation of centroid size). The analysis of univariate measures showed that Stage 1 humans did indeed possess the relatively shortest and most horizontally oriented CET's with the greatest amount of growth change occurring at the transition to Stage 2 (eruption of deciduous dentition at five postnatal months, commencing peak AOM incidence) and ceasing by Stage 3 (approximately six postnatal years). Skeletal indicators appear related to peak ages of AOM incidence and may contribute to understanding of a nearly ubiquitous human disease. Anat Rec, 2017. © 2017 Wiley Periodicals, Inc. Anat Rec, 300:1721-1740, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  11. Development and Preliminary Validation of a New Measure of Values in Scientific Work.

    Science.gov (United States)

    English, Tammy; Antes, Alison L; Baldwin, Kari A; DuBois, James M

    2018-04-01

    In this paper we describe the development and initial psychometric evaluation of a new measure, the values in scientific work (VSW). This scale assesses the level of importance that investigators attach to different VSW. It taps a broad range of intrinsic, extrinsic, and social values that motivate the work of scientists, including values specific to scientific work (e.g., truth and integrity) and more classic work values (e.g., security and prestige) in the context of science. Notably, the values represented in this scale are relevant to scientists regardless of their career stage and research focus. We administered the VSW and a measure of global values to 203 NIH-funded investigators. Exploratory factor analyses suggest the delineation of eight VSW, including autonomy, research ethics, social impact, income, collaboration, innovation and growth, conserving relationships, and job security. These VSW showed predictable and distinct associations with global values. Implications of these findings for work on research integrity and scientific misconduct are discussed.

  12. Measuring and Communicating the Value Created by an Organization

    Science.gov (United States)

    Sherman, W. Richard

    2010-01-01

    This paper offers a different perspective in measuring the value created by an organization. It does so in the context of an undergraduate course in managerial accounting. In order to break down the functional silo approach to problem solving that has become the model of traditional business education, applications of shadow accounting, the…

  13. Drivers of peak sales for pharmaceutical brands

    NARCIS (Netherlands)

    Fischer, Marc; Leeflang, Peter S. H.; Verhoef, Peter C.

    2010-01-01

    Peak sales are an important metric in the pharmaceutical industry. Specifically, managers are focused on the height-of-peak-sales and the time required achieving peak sales. We analyze how order of entry and quality affect the level of peak sales and the time-to-peak-sales of pharmaceutical brands.

  14. Application of a novel measure of EEG non-stationarity as 'Shannon- entropy of the peak frequency shifting' for detecting residual abnormalities in concussed individuals.

    Science.gov (United States)

    Cao, Cheng; Slobounov, Semyon

    2011-07-01

    The aim of this report was to propose a novel measure of non-stationarity of EEG signals, named Shannon- entropy of the peak frequency shifting (SEPFS). The feasibility of this method was documented comparing this measure with traditional time domain assessment of non-stationarity and its application to EEG data sets obtained from student-athletes before and after suffering a single episode of mild traumatic brain injury (mTBI) with age-matched normal controls. Instead of assessing the power density distribution on the time-frequency plane, like previously proposed measures of signal non-stationarity, this new measure is based on the shift of the dominant frequency of the EEG signal over time. We applied SEPFS measure to assess the properties of EEG non-stationarity in subjects before and shortly after they suffered mTBI. Student-athletes at high risk for mTBI (n=265) were tested prior to concussive episodes as a baseline. From this subject pool, 30 athletes who suffered from mTBI were retested on day 30 post-injury. Additional subjects pool (student-athletes without history of concussion, n=30) were recruited and test-re-tested within the same 30 day interval. Thirty-two channels EEG signals were acquired in sitting eyes closed condition. The results showed that the SEPFS values significantly decreased in subjects suffering from mTBI. Specifically, reduced EEG non-stationarity was observed in occipital, temporal and central brain areas, indicating the possibility of residual brain dysfunctions in concussed individuals. A similar but less statistically significant trend was observed using traditional time domain analysis of EEG non-stationarity. The proposed measure has at least two merits of interest: (1) it is less affected by the limited resolution of time-frequency representation of the EEG signal; (2) it takes into account the neural characteristics of the EEG signal that have not been considered in previously proposed measures of non-stationarity. This new

  15. Dissociated time course between peak torque and total work recovery following bench press training in resistance trained men.

    Science.gov (United States)

    Ferreira, Diogo V; Gentil, Paulo; Ferreira-Junior, João B; Soares, Saulo R S; Brown, Lee E; Bottaro, Martim

    2017-10-01

    To evaluate the time course of peak torque and total work recovery after a resistance training session involving the bench press exercise. Repeated measures with a within subject design. Twenty-six resistance-trained men (age: 23.7±3.7years; height: 176.0±5.7cm; mass: 79.65±7.61kg) performed one session involving eight sets of the bench press exercise performed to momentary muscle failure with 2-min rest between sets. Shoulder horizontal adductors peak torque (PT), total work (TW), delayed onset muscle soreness (DOMS) and subjective physical fitness were measured pre, immediately post, 24, 48, 72 and 96h following exercise. The exercise protocol resulted in significant pectoralis major DOMS that lasted for 72h. Immediately after exercise, the reduction in shoulder horizontal adductors TW (25%) was greater than PT (17%). TW, as a percentage of baseline values, was also less than PT at 24, 48 and 96h after exercise. Additionally, PT returned to baseline at 96h, while TW did not. Resistance trained men presented dissimilar PT and TW recovery following free weight bench press exercise. This indicates that recovery of maximal voluntary contraction does not reflect the capability to perform multiple contractions. Strength and conditioning professionals should be cautious when evaluating muscle recovery by peak torque, since it can lead to the repetition of a training session sooner than recommended. Copyright © 2017. Published by Elsevier Inc.

  16. The effect of energy peak drift on the calibration of a high resolution gamma-ray soil density gauge

    International Nuclear Information System (INIS)

    Henshall, J.K.

    1994-01-01

    High spatial resolution is obtained from a gamma-ray transmission density gauge by restricting the measured counts to a narrow band of the energy spectrum, close to the emission energy peak. The effect on measurement accuracy of any movement of this measurement window relative to the energy peak was investigated. The findings were related to anticipated energy peak movements in a proposed LED-based gain-stabilization system. Movements of the energy peaks during recording of unstabilized spectra prevented direct comparisons of spectra at different positions. A simulation procedure was, therefore, developed in which movements of the measurement window relative to sets of stable calibration spectra were examined. When analysing spectra, recorded using a gauge with a different gain-stabilization system, accuracy was found to be unaffected by simulated peak movements of up to 0.03 MeV in the direction of increasing energy. However, movements of stabilized spectra in the direction of decreasing energy, and of unstabilized spectra in either direction, increased measurement errors to twice the level of inherent measurement errors within 0.02 MeV, with errors in bulk density of up to 0.7 Mg m −3 for movements of 0.1 MeV. The spectra of the new LED-based stabilization system are expected to behave in a manner similar to the unstabilized system, therefore requiring regular monitoring of the peak position. (author)

  17. Association between infancy BMI peak and body composition and blood pressure at age 5-6 years

    NARCIS (Netherlands)

    Hof, Michel H. P.; Vrijkotte, Tanja G. M.; de Hoog, Marieke L. A.; van Eijsden, Manon; Zwinderman, Aeilko H.

    2013-01-01

    The development of overweight is often measured with the body mass index (BMI). During childhood the BMI curve has two characteristic points: the adiposity rebound at 6 years and the BMI peak at 9 months of age. In this study, the associations between the BMI peak and body composition measures and

  18. On the interplay between distortion, mean value and Haezendonck-Goovaerts risk measures

    NARCIS (Netherlands)

    Goovaerts, M.J.; Linders, D.; van Weert, K.; Tank, F.

    2012-01-01

    In the actuarial research, distortion, mean value and Haezendonck-Goovaerts risk measures are concepts that are usually treated separately. In this paper we indicate and characterize the relation between these different risk measures, as well as their relation to convex risk measures. While it is

  19. Relation between peak period of microtremor spectral ratio (horizontal and vertical components) and basement depth; Bido no suiheido/jogedo supekutoru hi no peak to kiso shindo tono kankei

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, H; Mizutani, K; Saito, T [Iwate University, Iwate (Japan). Faculty of Engineering

    1996-05-01

    The peak period of the horizontal/vertical spectral ratio of microtremors was referred to the underground structure for the purpose of finding out if it was possible to estimate the ground structure by use of the peak period of the spectral ratio. The observation was carried in the areas of Morioka City and Hachinohe City using seismographs for measuring east-west, north-south, and up-down motions. As for the relationship between the peak period of the spectral ratio distribution involving 490 observation sites and the known gravity anomalies in the Morioka City area, it was found that the peak period of the spectral ratio tended to be shorter from west toward east while the gravity anomalies were greater from west toward east. Again, as for the relations with the underground geology, the period was longer when the distance to the granite basement was greater, and shorter when smaller. In the Hachinohe City area, relations not only of the first period peak but also of the second period peak to the basement were disclosed, which indicates the possibility that the peak period of the spectral ratio will be used as a means for estimating the basement structure. 2 refs., 8 figs.

  20. Correlation Filter Learning Toward Peak Strength for Visual Tracking.

    Science.gov (United States)

    Sui, Yao; Wang, Guanghui; Zhang, Li

    2018-04-01

    This paper presents a novel visual tracking approach to correlation filter learning toward peak strength of correlation response. Previous methods leverage all features of the target and the immediate background to learn a correlation filter. Some features, however, may be distractive to tracking, like those from occlusion and local deformation, resulting in unstable tracking performance. This paper aims at solving this issue and proposes a novel algorithm to learn the correlation filter. The proposed approach, by imposing an elastic net constraint on the filter, can adaptively eliminate those distractive features in the correlation filtering. A new peak strength metric is proposed to measure the discriminative capability of the learned correlation filter. It is demonstrated that the proposed approach effectively strengthens the peak of the correlation response, leading to more discriminative performance than previous methods. Extensive experiments on a challenging visual tracking benchmark demonstrate that the proposed tracker outperforms most state-of-the-art methods.

  1. Mask effects on cosmological studies with weak-lensing peak statistics

    International Nuclear Information System (INIS)

    Liu, Xiangkun; Pan, Chuzhong; Fan, Zuhui; Wang, Qiao

    2014-01-01

    With numerical simulations, we analyze in detail how the bad data removal, i.e., the mask effect, can influence the peak statistics of the weak-lensing convergence field reconstructed from the shear measurement of background galaxies. It is found that high peak fractions are systematically enhanced because of the presence of masks; the larger the masked area is, the higher the enhancement is. In the case where the total masked area is about 13% of the survey area, the fraction of peaks with signal-to-noise ratio ν ≥ 3 is ∼11% of the total number of peaks, compared with ∼7% of the mask-free case in our considered cosmological model. This can have significant effects on cosmological studies with weak-lensing convergence peak statistics, inducing a large bias in the parameter constraints if the effects are not taken into account properly. Even for a survey area of 9 deg 2 , the bias in (Ω m , σ 8 ) is already intolerably large and close to 3σ. It is noted that most of the affected peaks are close to the masked regions. Therefore, excluding peaks in those regions in the peak statistics can reduce the bias effect but at the expense of losing usable survey areas. Further investigations find that the enhancement of the number of high peaks around the masked regions can be largely attributed to the smaller number of galaxies usable in the weak-lensing convergence reconstruction, leading to higher noise than that of the areas away from the masks. We thus develop a model in which we exclude only those very large masks with radius larger than 3' but keep all the other masked regions in peak counting statistics. For the remaining part, we treat the areas close to and away from the masked regions separately with different noise levels. It is shown that this two-noise-level model can account for the mask effect on peak statistics very well, and the bias in cosmological parameters is significantly reduced if this model is applied in the parameter fitting.

  2. Physical activity as a long-term predictor of peak oxygen uptake: the HUNT Study.

    Science.gov (United States)

    Aspenes, Stian Thoresen; Nauman, Javaid; Nilsen, Tom Ivar Lund; Vatten, Lars Johan; Wisløff, Ulrik

    2011-09-01

    A physically active lifestyle and a relatively high level of cardiorespiratory fitness are important for longevity and long-term health. No population-based study has prospectively assessed the association of physical activity levels with long-term peak oxygen uptake (VO(2peak)). 1843 individuals (906 women and 937 men) who were between 18 and 66 yr at baseline and were free from known lung or heart diseases at both baseline (1984-1986) and follow-up (2006-2008) were included in the study. Self-reported physical activity was recorded at both occasions, and VO(2peak) was measured at follow-up. The association of physical activity levels and VO(2peak) was adjusted for age, level of education, smoking status, and weight change from baseline to follow-up, using ANCOVA statistics. The level of physical activity at baseline was strongly associated with VO(2peak) at follow-up 23 yr later in both men and women (Ptrends active at baseline had higher (3.3 and 4.6 mL·kg(-1)·min(-1)) VO(2peak) at follow-up. Women who were inactive at baseline but highly active at follow-up had 3.7 mL·kg(-1)·min(-1) higher VO(2peak) compared with women who were inactive both at baseline and at follow-up. The corresponding comparison in men showed a difference of 5.2 mL·kg(-1)·min(-1) (95% confidence interval = 3.1-7.3) in VO(2peak). Physical activity level at baseline was positively associated with directly measured cardiorespiratory fitness (VO(2peak)) 23 yr later. People who changed from low to high activity during the observation period had substantially higher V˙O(2peak) at follow-up compared with people whose activity remained low.

  3. Uncertainty in relative energy resolution measurements

    International Nuclear Information System (INIS)

    Volkovitsky, P.; Yen, J.; Cumberland, L.

    2007-01-01

    We suggest a new method for the determination of the detector relative energy resolution and its uncertainty based on spline approximation of experimental spectra and a statistical bootstrapping procedure. The proposed method is applied to the spectra obtained with NaI(Tl) scintillating detectors and 137 Cs sources. The spectrum histogram with background subtracted channel-by-channel is modeled by cubic spline approximation. The relative energy resolution (which is also known as pulse height resolution and energy resolution), defined as the full-width at half-maximum (FWHM) divided by the value of peak centroid, is calculated using the intercepts of the spline curve with the line of the half peak height. The value of the peak height is determined as the point where the value of the derivative goes to zero. The residuals, which are normalized over the square root of counts in a given bin (y-coordinate), obey the standard Gaussian distribution. The values of these residuals are randomly re-assigned to a different set of y-coordinates where a new 'pseudo-experimental' data set is obtained after 'de-normalization' of the old values. For this new data set a new spline approximation is found and the whole procedure is repeated several hundred times, until the standard deviation of relative energy resolution becomes stabilized. The standard deviation of relative energy resolutions calculated for each 'pseudo-experimental' data set (bootstrap uncertainty) is considered to be an estimate for relative energy resolution uncertainty. It is also shown that the relative bootstrap uncertainty is proportional to, and generally only two to three times bigger than, 1/√(N tot ), which is the relative statistical count uncertainty (N tot is the total number of counts under the peak). The newly suggested method is also applicable to other radiation and particle detectors, not only for relative energy resolution, but also for any of the other parameters in a measured spectrum, like

  4. Flood frequency analysis for nonstationary annual peak records in an urban drainage basin

    Science.gov (United States)

    Villarini, G.; Smith, J.A.; Serinaldi, F.; Bales, J.; Bates, P.D.; Krajewski, W.F.

    2009-01-01

    Flood frequency analysis in urban watersheds is complicated by nonstationarities of annual peak records associated with land use change and evolving urban stormwater infrastructure. In this study, a framework for flood frequency analysis is developed based on the Generalized Additive Models for Location, Scale and Shape parameters (GAMLSS), a tool for modeling time series under nonstationary conditions. GAMLSS is applied to annual maximum peak discharge records for Little Sugar Creek, a highly urbanized watershed which drains the urban core of Charlotte, North Carolina. It is shown that GAMLSS is able to describe the variability in the mean and variance of the annual maximum peak discharge by modeling the parameters of the selected parametric distribution as a smooth function of time via cubic splines. Flood frequency analyses for Little Sugar Creek (at a drainage area of 110 km2) show that the maximum flow with a 0.01-annual probability (corresponding to 100-year flood peak under stationary conditions) over the 83-year record has ranged from a minimum unit discharge of 2.1 m3 s- 1 km- 2 to a maximum of 5.1 m3 s- 1 km- 2. An alternative characterization can be made by examining the estimated return interval of the peak discharge that would have an annual exceedance probability of 0.01 under the assumption of stationarity (3.2 m3 s- 1 km- 2). Under nonstationary conditions, alternative definitions of return period should be adapted. Under the GAMLSS model, the return interval of an annual peak discharge of 3.2 m3 s- 1 km- 2 ranges from a maximum value of more than 5000 years in 1957 to a minimum value of almost 8 years for the present time (2007). The GAMLSS framework is also used to examine the links between population trends and flood frequency, as well as trends in annual maximum rainfall. These analyses are used to examine evolving flood frequency over future decades. ?? 2009 Elsevier Ltd.

  5. How Can Value-Added Measures Be Used for Teacher Improvement? What We Know Series: Value-Added Methods and Applications. Knowledge Brief 13

    Science.gov (United States)

    Loeb, Susanna

    2013-01-01

    The question for this brief is whether education leaders can use value-added measures as tools for improving schooling and, if so, how to do this. Districts, states, and schools can, at least in theory, generate gains in educational outcomes for students using value-added measures in three ways: creating information on effective programs, making…

  6. A scheme of quantum state discrimination over specified states via weak-value measurement

    Science.gov (United States)

    Chen, Xi; Dai, Hong-Yi; Liu, Bo-Yang; Zhang, Ming

    2018-04-01

    The commonly adopted projective measurements are invalid in the specified task of quantum state discrimination when the discriminated states are superposition of planar-position basis states whose complex-number probability amplitudes have the same magnitude but different phases. Therefore we propose a corresponding scheme via weak-value measurement and examine the feasibility of this scheme. Furthermore, the role of the weak-value measurement in quantum state discrimination is analyzed and compared with one in quantum state tomography in this Letter.

  7. Investigation of the effective peak supersaturation for liquid-phase clouds at the high-alpine site Jungfraujoch, Switzerland (3580 m a.s.l.

    Directory of Open Access Journals (Sweden)

    E. Hammer

    2014-01-01

    Full Text Available Aerosols influence the Earth's radiation budget directly through absorption and scattering of solar radiation in the atmosphere but also indirectly by modifying the properties of clouds. However, climate models still suffer from large uncertainties as a result of insufficient understanding of aerosol-cloud interactions. At the high altitude research station Jungfraujoch (JFJ; 3580 m a.s.l., Switzerland cloud condensation nuclei (CCN number concentrations at eight different supersaturations (SS from 0.24% to 1.18% were measured using a CCN counter during Summer 2011. Simultaneously, in-situ aerosol activation properties of the prevailing ambient clouds were investigated by measuring the total and interstitial (non-activated dry particle number size distributions behind two different inlet systems. Combining all experimental data, a new method was developed to retrieve the so-called effective peak supersaturation SSpeak, as a measure of the SS at which ambient clouds are formed. A 17-month CCN climatology was then used to retrieve the SSpeak values also for four earlier summer campaigns (2000, 2002, 2004 and 2010 where no direct CCN data were available. The SSpeak values varied between 0.01% and 2.0% during all campaigns. An overall median SSpeak of 0.35% and dry activation diameter of 87 nm was observed. It was found that the difference in topography between northwest and southeast plays an important role for the effective peak supersaturation in clouds formed in the vicinity of the JFJ, while differences in the number concentration of potential CCN only play a minor role. Results show that air masses coming from the southeast (with the slowly rising terrain of the Aletsch Glacier generally experience lower SSpeak values than air masses coming from the northwest (steep slope. The observed overall median values were 0.41% and 0.22% for northwest and southeast wind conditions, respectively, corresponding to literature values for cumulus clouds and

  8. How to use your peak flow meter

    Science.gov (United States)

    ... meter - how to use; Asthma - peak flow meter; Reactive airway disease - peak flow meter; Bronchial asthma - peak ... 2014:chap 55. National Asthma Education and Prevention Program website. How to use a peak flow meter. ...

  9. [THE FETAL MIDDLE CEREBRAL ARTERY PEAK SYSTOLIC VELOCITY AS A PEDICTOR OF FETAL ANEMIA IN RH-ALLOIMMUNIZED PREGNANCY].

    Science.gov (United States)

    Markov, D; Pavlova, E; Atanassova, D; Diavolov, V; Hitrova, S; Vakrilova, L; Pramatarova, T; Slancheva, B; Ivanov, St

    2015-01-01

    Rh-isoimmunization is a pathological condition in which the fetal red blood cells of a Rh (+) fetus are destroyed by the isoantibodies of a Rh (-) woman sensitized in a previous event. Despite of the wide spread implementation of anti D-gammaglobolin prophylaxis this is still the most common cause for fetal anemia. Recently, sonographic measurement of the fetal middle cerebral artery peak systolic velocity (MCA-PSV) has been shown to be an accurate non-invasive test to predict low fetal hemoglobin levels. We present a case report of Rh-alloimmunized pregnancy with moderate fetal anemia, followed-up by weekly MCA-PSV measurements. A 37-year-old Rh (-) negative gravida 3, para 1, without anti-D gammaglobolin prophylaxis in her previous pregnancies, presented at 27+0 weeks of gestation (w.g.) for a routine third trimester scan. Subsequent ultrasound measurements of MCA-PSV confirmed a progressive increase of the peak systolic velocities from 40 to 80 cm/sec, as well as a gradual rise in the anti-D titers. The evidence of developing fetal anemia necessitated elective Caesarean section performed at 35 wg. The neonate was admitted in the intensive care unit and required resuscitation, one exchange blood transfusion and several courses of phototherapy. The patient was discharged two weeks post partum. There is a strong correlation between the high peak systolic velocities in the middle cerebral artery (MCA-PSV) and the low levels of fetal hemoglobin. The high sensitivity and positive predictive value concerning the development of fetal anemia, as well as its good repeatability, makes this non-invasive test a valuable asset in the management of all pregnancies complicated by severe Rh-alloimmunization.

  10. On one-parametric formula relating the frequencies of twin-peak quasi-periodic oscillations

    Science.gov (United States)

    Török, Gabriel; Goluchová, Kateřina; Šrámková, Eva; Horák, Jiří; Bakala, Pavel; Urbanec, Martin

    2018-01-01

    Twin-peak quasi-periodic oscillations (QPOs) are observed in several low-mass X-ray binary systems containing neutron stars. Timing the analysis of X-ray fluxes of more than dozen of such systems reveals remarkable correlations between the frequencies of two characteristic peaks present in the power density spectra. The individual correlations clearly differ, but they roughly follow a common individual pattern. High values of measured QPO frequencies and strong modulation of the X-ray flux both suggest that the observed correlations are connected to orbital motion in the innermost part of an accretion disc. Several attempts to model these correlations with simple geodesic orbital models or phenomenological relations have failed in the past. We find and explore a surprisingly simple analytic relation that reproduces individual correlations for a group of several sources through a single parameter. When an additional free parameter is considered within our relation, it well reproduces the data of a large group of 14 sources. The very existence and form of this simple relation support the hypothesis of the orbital origin of QPOs and provide the key for further development of QPO models. We discuss a possible physical interpretation of our relation's parameters and their links to concrete QPO models.

  11. Reference values for physical performance measures in the aging working population.

    Science.gov (United States)

    Cote, Mark P; Kenny, Anne; Dussetschleger, Jeffrey; Farr, Dana; Chaurasia, Ashok; Cherniack, Martin

    2014-02-01

    The aim of this study was to determine reference physical performance values in older aging workers. Cross-sectional physical performance measures were collected for 736 manufacturing workers to assess effects of work and nonwork factors on age-related changes in musculoskeletal function and health. Participants underwent surveys and physical testing that included bioelectrical impedance analysis, range-of-motion measures, exercise testing, and dynamic assessment. Physical characteristics, such as blood pressure and body fat percentage, were comparable to published values. Dynamic and range-of-motion measurements differed from published normative results. Women had age-related decreases in cervical extension and lateral rotation. Older men had better spinal flexion than expected. Predicted age-related decline in lower-extremity strength and shoulder strength in women was not seen. Men declined in handgrip, lower-extremity strength, and knee extension strength, but not trunk strength, across age groups. There was no appreciable decline in muscle fatigue at the trunk, shoulder, and knee with aging for either gender, except for the youngest age group of women. Normative values may underestimate physical performance in "healthy" older workers, thereby underappreciating declines in less healthy older workers. Work may be preservative of function for a large group of selected individuals. A "healthy worker effect" may be greater for musculoskeletal disease and function than for heart disease and mortality. Clinicians and researchers studying musculoskeletal function in older workers can use a more specific set of reference values.

  12. Measuring the value of groundwater and other forms of natural capital.

    Science.gov (United States)

    Fenichel, Eli P; Abbott, Joshua K; Bayham, Jude; Boone, Whitney; Haacker, Erin M K; Pfeiffer, Lisa

    2016-03-01

    Valuing natural capital is fundamental to measuring sustainability. The United Nations Environment Programme, World Bank, and other agencies have called for inclusion of the value of natural capital in sustainability metrics, such as inclusive wealth. Much has been written about the importance of natural capital, but consistent, rigorous valuation approaches compatible with the pricing of traditional forms of capital have remained elusive. We present a guiding quantitative framework enabling natural capital valuation that is fully consistent with capital theory, accounts for biophysical and economic feedbacks, and can guide interdisciplinary efforts to measure sustainability. We illustrate this framework with an application to groundwater in the Kansas High Plains Aquifer, a rapidly depleting asset supporting significant food production. We develop a 10-y time series (1996-2005) of natural capital asset prices that accounts for technological, institutional, and physical changes. Kansas lost approximately $110 million per year (2005 US dollars) of capital value through groundwater withdrawal and changes in aquifer management during the decade spanning 1996-2005. This annual loss in wealth is approximately equal to the state's 2005 budget surplus, and is substantially more than investments in schools over this period. Furthermore, real investment in agricultural capital also declined over this period. Although Kansas' depletion of water wealth is substantial, it may be tractably managed through careful groundwater management and compensating investments in other natural and traditional assets. Measurement of natural capital value is required to inform management and ongoing investments in natural assets.

  13. Measurement of peak impact loads differ between accelerometers - Effects of system operating range and sampling rate.

    Science.gov (United States)

    Ziebart, Christina; Giangregorio, Lora M; Gibbs, Jenna C; Levine, Iris C; Tung, James; Laing, Andrew C

    2017-06-14

    A wide variety of accelerometer systems, with differing sensor characteristics, are used to detect impact loading during physical activities. The study examined the effects of system characteristics on measured peak impact loading during a variety of activities by comparing outputs from three separate accelerometer systems, and by assessing the influence of simulated reductions in operating range and sampling rate. Twelve healthy young adults performed seven tasks (vertical jump, box drop, heel drop, and bilateral single leg and lateral jumps) while simultaneously wearing three tri-axial accelerometers including a criterion standard laboratory-grade unit (Endevco 7267A) and two systems primarily used for activity-monitoring (ActiGraph GT3X+, GCDC X6-2mini). Peak acceleration (gmax) was compared across accelerometers, and errors resulting from down-sampling (from 640 to 100Hz) and range-limiting (to ±6g) the criterion standard output were characterized. The Actigraph activity-monitoring accelerometer underestimated gmax by an average of 30.2%; underestimation by the X6-2mini was not significant. Underestimation error was greater for tasks with greater impact magnitudes. gmax was underestimated when the criterion standard signal was down-sampled (by an average of 11%), range limited (by 11%), and by combined down-sampling and range-limiting (by 18%). These effects explained 89% of the variance in gmax error for the Actigraph system. This study illustrates that both the type and intensity of activity should be considered when selecting an accelerometer for characterizing impact events. In addition, caution may be warranted when comparing impact magnitudes from studies that use different accelerometers, and when comparing accelerometer outputs to osteogenic impact thresholds proposed in literature. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  14. Measurement of disintegration rates of small [60Co]Co sources in lead containers by the sum-peak method

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1991-01-01

    The sum-peak method has been applied to determine the disintegration rates of two small [ 60 Co]Co sources (30 and 350 kBq) in lead containers with several thickness by using a NaI(Tl) detector. The experimental results showed that the sum-peak method was perfectly effective for the determination of the disintegration rates (unrelated to the thicknesses of the containers) of the 350 kBq source. The sum-peak method was also absolutely effective for the 30 kBq source in the case of containers with thicknesses of 15 mm and less, but in the cases of those with thicknesses of 21, 27 and 33 mm, the disintegration rates were under-estimated and the deviations from the true disintegration rate increased rapidly with increasing thicknesses of the containers. We presume that the under-estimation of the disintegration rates was the result of the over-estimation of the areas under the sum peaks, caused by the interference of the γ-ray (2614 keV) emitted from the naturally occurring radionuclide 208 Tl. (author)

  15. Issue of ecological impacts due to hydro-peaking management. Characterization of hydro-peaks - Operating experience on Maronne River; Impacts ecologiques des eclusees hydroelectriques. Caracterisaton des regimes d'eclusees et Retour d'experience sur la Maronne

    Energy Technology Data Exchange (ETDEWEB)

    Courret, Dominique; Larinier, Michel [Office National de l' Eau et des Milieux Aquatiques - ONEMA, Pole Ecohydraulique, IMFT, Cemagref, Avenue du Professeur Camille Soula, 31400 Toulouse (France); Chanseau, Matthieu [MIGADO, 18ter rue de la Garonne - 47520 Le Passage (France); Office National de l' Eau et des Milieux Aquatiques - ONEMA, Direction Interregionale de Toulouse, Avenue du Professeur Camille Soula, 31400 Toulouse (France); Lascaux, Jean-Marc [Etudes et COnseils en Gestion de l' Environnement Aquatique - ECOGEA, 10 avenue de Toulouse, 31860 Pins-Justaret (France)

    2012-01-15

    Hydro-peaking management can consistently alter fish populations, and particularly recruitment of diadromous species, like salmon. To progress in understanding the impacts and defining mitigation measures, it appears essential to combine long-term biological survey, hydrological analysis including hydro-peaks characterization, and hydro-morphologic approach. In a first time, a methodology for hydrological characterization of hydro-peaks is presented. Their diversity and high variability are illustrated. Then, we present operating experience on Maronne River, a tributary of the Dordogne River downstream Argentat affected by hydro-peaks of Hautefage scheme. Biological surveys and hydrologic and hydro-morphologic studies allowed a better understanding and a quantification of some biological impacts (redds dewatering, stranding-trapping of alevins), to support mitigation measures and to assess its effectiveness. The relevance of work on morphology, in addition to measures on flow management, is also illustrated. Some positive results have already been obtained. Studies on the Maronne River are pursued to achieve a really satisfactory situation. This example shows that the current knowledge does not allow, on a given stream, to pre-define mitigation measures and ensure their efficiency. This leads to advocate the setting up of similar approach on other river, to identify biological communities' responses depending on the characteristics of hydro-peaks and hydro-systems. (authors)

  16. Measurement of xenon reactivity in the reactor of the nuclear ship 'MUTSU'

    International Nuclear Information System (INIS)

    Itagaki, Masafumi; Miyoshi, Yoshinori; Gakuhari, Kazuhiko; Okada, Noboru.

    1993-01-01

    This report deals with the measurement of reactivity changes caused by the increase and decrease of xenon concentration in the reactor core of the nuclear ship 'MUTSU' after a change from long-term operation at 70 % to zero power. The change in xenon reactivity was compensated by control-rod movements and the compensated reactivity was measured using a digital reactivity meter. The xenon override peak was recognized five and half hours after the start of power reduction. The equilibrium and peak reactivities of xenon were estimated by reading the initial and peak values of a theoretical curve which was fitted to the measured variation in xenon reactivity. The xenon reactivity results obtained by the present method can be considered to be accurate since no control-rod worth data were used and the measured quantity was the reactivity itself. (author)

  17. A National Trial on Differences in Cerebral Perfusion Pressure Values by Measurement Location.

    Science.gov (United States)

    McNett, Molly M; Bader, Mary Kay; Livesay, Sarah; Yeager, Susan; Moran, Cristina; Barnes, Arianna; Harrison, Kimberly R; Olson, DaiWai M

    2018-04-01

    Cerebral perfusion pressure (CPP) is a key parameter in management of brain injury with suspected impaired cerebral autoregulation. CPP is calculated by subtracting intracranial pressure (ICP) from mean arterial pressure (MAP). Despite consensus on importance of CPP monitoring, substantial variations exist on anatomical reference points used to measure arterial MAP when calculating CPP. This study aimed to identify differences in CPP values based on measurement location when using phlebostatic axis (PA) or tragus (Tg) as anatomical reference points. The secondary study aim was to determine impact of differences on patient outcomes at discharge. This was a prospective, repeated measures, multi-site national trial. Adult ICU patients with neurological injury necessitating ICP and CPP monitoring were consecutively enrolled from seven sites. Daily MAP/ICP/CPP values were gathered with the arterial transducer at the PA, followed by the Tg as anatomical reference points. A total of 136 subjects were enrolled, resulting in 324 paired observations. There were significant differences for CPP when comparing values obtained at PA and Tg reference points (p Differences remained significant in repeated measures model when controlling for clinical factors (mean CPP-PA = 80.77, mean CPP-Tg = 70.61, p identified as adequate with PA values, yet inadequate with CPP values measured at the Tg. Findings identify numerical differences for CPP based on anatomical reference location and highlight importance of a standard reference point for both clinical practice and future trials to limit practice variations and heterogeneity of findings.

  18. PeakCaller: an automated graphical interface for the quantification of intracellular calcium obtained by high-content screening.

    Science.gov (United States)

    Artimovich, Elena; Jackson, Russell K; Kilander, Michaela B C; Lin, Yu-Chih; Nestor, Michael W

    2017-10-16

    Intracellular calcium is an important ion involved in the regulation and modulation of many neuronal functions. From regulating cell cycle and proliferation to initiating signaling cascades and regulating presynaptic neurotransmitter release, the concentration and timing of calcium activity governs the function and fate of neurons. Changes in calcium transients can be used in high-throughput screening applications as a basic measure of neuronal maturity, especially in developing or immature neuronal cultures derived from stem cells. Using human induced pluripotent stem cell derived neurons and dissociated mouse cortical neurons combined with the calcium indicator Fluo-4, we demonstrate that PeakCaller reduces type I and type II error in automated peak calling when compared to the oft-used PeakFinder algorithm under both basal and pharmacologically induced conditions. Here we describe PeakCaller, a novel MATLAB script and graphical user interface for the quantification of intracellular calcium transients in neuronal cultures. PeakCaller allows the user to set peak parameters and smoothing algorithms to best fit their data set. This new analysis script will allow for automation of calcium measurements and is a powerful software tool for researchers interested in high-throughput measurements of intracellular calcium.

  19. Constraining the shape of the CMB: A peak-by-peak analysis

    International Nuclear Information System (INIS)

    Oedman, Carolina J.; Hobson, Michael P.; Lasenby, Anthony N.; Melchiorri, Alessandro

    2003-01-01

    The recent measurements of the power spectrum of cosmic microwave background anisotropies are consistent with the simplest inflationary scenario and big bang nucleosynthesis constraints. However, these results rely on the assumption of a class of models based on primordial adiabatic perturbations, cold dark matter and a cosmological constant. In this paper we investigate the need for deviations from the Λ-CDM scenario by first characterizing the spectrum using a phenomenological function in a 15 dimensional parameter space. Using a Monte Carlo Markov chain approach to Bayesian inference and a low curvature model template we then check for the presence of new physics and/or systematics in the CMB data. We find an almost perfect consistency between the phenomenological fits and the standard Λ-CDM models. The curvature of the secondary peaks is weakly constrained by the present data, but they are well located. The improved spectral resolution expected from future satellite experiments is warranted for a definitive test of the scenario

  20. Imaging and measurement of T1 value by NMR of low magnetic field

    International Nuclear Information System (INIS)

    Asai, Hideaki; Izawa, Akira; Furuse, Kazuhiro; Saoi, Katsuyoshi; Nagai, Masahiko.

    1983-01-01

    FONAR QED-80α having two operating mode: the anatomy mode to obtain an image of proton densities and the chemistry mode to measure T 1 value at a region of intenst, was used clinically. The strength of static magnetic field is 0.041T. 32 cases, 18 healthy volunteers and 14 patients were studied. In proton density imaging, high proton density organs such as skin were imaged bright, and low proton density organs such as bones and flowing blood were imaged dark. The merits of NMR imaging are no artifacts caused by bones and air. However, NMR image is required long time for measurement and the image of NMR is unsharp than that of X-ray CT. Concerning with T 1 value, cerebral and cerebellar gray matter had longer T 1 's than that of white matter. Pathological lesions, such as tumor and/or infarct, had also longer T 1 values than these of normal tissue. The value of T 1 was thought to be applicable clinically except for some problems, such as measuring T 1 value of large extent. No side effects were found during and after examinations. (author)

  1. A Value Measure for Public-Sector Enterprise Risk Management: A TSA Case Study.

    Science.gov (United States)

    Fletcher, Kenneth C; Abbas, Ali E

    2018-05-01

    This article presents a public value measure that can be used to aid executives in the public sector to better assess policy decisions and maximize value to the American people. Using Transportation Security Administration (TSA) programs as an example, we first identify the basic components of public value. We then propose a public value account to quantify the outcomes of various risk scenarios, and we determine the certain equivalent of several important TSA programs. We illustrate how this proposed measure can quantify the effects of two main challenges that government organizations face when conducting enterprise risk management: (1) short-term versus long-term incentives and (2) avoiding potential negative consequences even if they occur with low probability. Finally, we illustrate how this measure enables the use of various tools from decision analysis to be applied in government settings, such as stochastic dominance arguments and certain equivalent calculations. Regarding the TSA case study, our analysis demonstrates the value of continued expansion of the TSA trusted traveler initiative and increasing the background vetting for passengers who are afforded expedited security screening. © 2017 Society for Risk Analysis.

  2. Acute effects of static stretching on peak and end-range hamstring-to-quadriceps functional ratios

    Science.gov (United States)

    Sekir, Ufuk; Arabaci, Ramiz; Akova, Bedrettin

    2015-01-01

    AIM: To evaluate if static stretching influences peak and end-range functional hamstring-to-quadriceps (H/Q) strength ratios in elite women athletes. METHODS: Eleven healthy female athletes in an elite competitive level participated to the study. All the participants fulfilled the static stretching or non-stretching (control) intervention protocol in a randomized design on different days. Two static unassisted stretching exercises, one in standing and one in sitting position, were used to stretch both the hamstring and quadriceps muscles during these protocols. The total time for the static stretching was 6 ± 1 min. The isokinetic peak torque measurements for the hamstring and quadriceps muscles in eccentric and concentric modes and the calculations for the functional H/Q strength ratios at angular velocities of 60°/s and 180°/s were made before (pre) and after (post) the control or stretching intervention. The strength measurements and functional strength ratio calculations were based during the entire- and end-range of knee extension. RESULTS: The pre-test scores for quadriceps and hamstring peak torque and end range values were not significantly different between the groups (P > 0.05). Subsequently, although the control group did not exhibit significant changes in quadriceps and hamstring muscle strength (P > 0.05), static stretching decreased eccentric and concentric quadriceps muscle strength at both the 60°/s and 180°/s test speeds (P hamstring muscle strength at both the 60°/s and 180°/s test speeds (P 0.05). Furthermore, the functional H/Q strength ratios exhibited no significant alterations during the entire and end ranges of knee extension both in the static stretching or the control intervention (P > 0.05). CONCLUSION: According to our results, static stretching routine does not influence functional H/Q ratio. Athletes can confidently perform static stretching during their warm-up routines. PMID:26495249

  3. Measuring and Managing Value Co-Creation Process: Overview of Existing Theoretical Models

    Directory of Open Access Journals (Sweden)

    Monika Skaržauskaitė

    2013-08-01

    Full Text Available Purpose — the article is to provide a holistic view on concept of value co-creation and existing models for measuring and managing it by conducting theoretical analysis of scientific literature sources targeting the integration of various approaches. Most important and relevant results of the literature study are presented with a focus on changed roles of organizations and consumers. This article aims at contributing theoretically to the research stream of measuring co-creation of value in order to gain knowledge for improvement of organizational performance and enabling new and innovative means of value creation. Design/methodology/approach. The nature of this research is exploratory – theoretical analysis and synthesis of scientific literature sources targeting the integration of various approaches was performed. This approach was chosen due to the absence of established theory on models of co-creation, possible uses in organizations and systematic overview of tools measuring/suggesting how to measure co-creation. Findings. While the principles of managing and measuring co-creation in regards of consumer motivation and involvement are widely researched, little attempt has been made to identify critical factors and create models dealing with organizational capabilities and managerial implications of value co-creation. Systematic analysis of literature revealed a gap not only in empirical research concerning organization’s role in co-creation process, but in theoretical and conceptual levels, too. Research limitations/implications. The limitations of this work as a literature review lies in its nature – the complete reliance on previously published research papers and the availability of these studies. For a deeper understanding of co-creation management and for developing models that can be used in real-life organizations, a broader theoretical, as well as empirical, research is necessary. Practical implications. Analysis of the

  4. Cassini Ion Mass Spectrometer Peak Calibrations from Statistical Analysis of Flight Data

    Science.gov (United States)

    Woodson, A. K.; Johnson, R. E.

    2017-12-01

    The Cassini Ion Mass Spectrometer (IMS) is an actuating time-of-flight (TOF) instrument capable of resolving ion mass, energy, and trajectory over a field of view that captures nearly the entire sky. One of three instruments composing the Cassini Plasma Spectrometer, IMS sampled plasma throughout the Kronian magnetosphere from 2004 through 2012 when it was permanently disabled due to an electrical malfunction. Initial calibration of the flight instrument at Southwest Research Institute (SwRI) was limited to a handful of ions and energies due to time constraints, with only about 30% of planned measurements carried out prior to launch. Further calibration measurements were subsequently carried out after launch at SwRI and Goddard Space Flight Center using the instrument prototype and engineering model, respectively. However, logistical differences among the three calibration efforts raise doubts as to how accurately the post-launch calibrations describe the behavior of the flight instrument. Indeed, derived peak parameters for some ion species differ significantly from one calibration to the next. In this study we instead perform a statistical analysis on 8 years of flight data in order to extract ion peak parameters that depend only on the response of the flight instrument itself. This is accomplished by first sorting the TOF spectra based on their apparent compositional similarities (e.g. primarily water group ions, primarily hydrocarbon ions, etc.) and normalizing each spectrum. The sorted, normalized data are then binned according to TOF, energy, and counts in order to generate energy-dependent probability density maps of each ion peak contour. Finally, by using these density maps to constrain a stochastic peak fitting algorithm we extract confidence intervals for the model parameters associated with various measured ion peaks, establishing a logistics-independent calibration of the body of IMS data gathered over the course of the Cassini mission.

  5. Energy peaks: A high energy physics outlook

    Science.gov (United States)

    Franceschini, Roberto

    2017-12-01

    Energy distributions of decay products carry information on the kinematics of the decay in ways that are at the same time straightforward and quite hidden. I will review these properties and discuss their early historical applications, as well as more recent ones in the context of (i) methods for the measurement of masses of new physics particle with semi-invisible decays, (ii) the characterization of Dark Matter particles produced at colliders, (iii) precision mass measurements of Standard Model particles, in particular of the top quark. Finally, I will give an outlook of further developments and applications of energy peak method for high energy physics at colliders and beyond.

  6. Analysis of read-out heating rate effects on the glow peaks of TLD-100 using WinGCF software

    Energy Technology Data Exchange (ETDEWEB)

    Bauk, Sabar, E-mail: sabar@usm.my [Physics Section, School of Distance Education, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Hussin, Siti Fatimah [School of Physics, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Alam, Md. Shah [Physics Section, School of Distance Education, Universiti Sains Malaysia, 11800 USM, Penang (Malaysia); Physics Department, Shahjalal University of Science and Technology, Sylhet (Bangladesh)

    2016-01-22

    This study was done to analyze the effects of the read-out heating rate on the LiF:Mg,Ti (TLD-100) thermoluminescent dosimeters (TLD) glow peaks using WinGCF computer software. The TLDs were exposed to X-ray photons with a potential difference of 72 kVp and 200 mAs in air and were read-out using a Harshaw 3500 TLD reader. The TLDs were read-out using four read-out heating rates at 10, 7, 4 and 1 °C s{sup −1}. It was observed that lowering the heating rate could separate more glow peaks. The activation energy for peak 5 was found to be lower than that for peak 4. The peak maximum temperature and the integral value of the main peak decreased as the heating rate decreases.

  7. [Diagnostic value of baseline serum luteinizing hormone level for central precocious puberty in girls].

    Science.gov (United States)

    Ou-Yang, Li-Xue; Yang, Fan

    2017-07-01

    To evaluate the diagnostic value of baseline serum luteinizing hormone (LH) level for central precocious puberty (CPP) in girls. A total of 279 girls with precocious puberty were subjected to assessment of growth and development, bone age determination, baseline LH test, and follicle-stimulating hormone (FSH) test, gonadotropin-releasing hormone stimulation test, and other related examinations. Of the 279 patients, 175 were diagnosed with CPP and 104 with premature thelarche (PT). The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic value of baseline LH and FSH levels and their peak levels for CPP, and the correlation between the baseline LH level and the peak LH level was analyzed. The CPP group had significantly higher bone age, baseline LH and FSH levels, peak LH and FSH levels, and ratio of peak LH level to peak FSH level than the PT group (Pbaseline LH level and peak LH level had good diagnostic values for CPP. Among the three bone age subgroups in the CPP group (7.0-9.0 years, 9.0-11.0 years, and >11.0 years), baseline LH level showed the best diagnostic value in the >11.0 years subgroup, with the largest area under the ROC curve. At a baseline LH level of 0.45 IU/L, the Youden index reached the peak value, and the sensitivity and specificity were 66.7% and 80% respectively, for the diagnosis of CPP. At a peak LH level of 9.935 IU/L, the Youden index reached the peak value, and the sensitivity and specificity were 74.8% and 100% respectively, for the diagnosis of CPP. The baseline LH level was positively correlated with the peak LH level (r=0.440, PBaseline LH level can be used as an primary screening index for the diagnosis of CPP. It has a certain diagnostic value for CPP at different bone ages, and may be used as a monitoring index during the treatment and follow-uP.

  8. Noninvasive measurement of cardiopulmonary blood volume: evaluation of the centroid method

    International Nuclear Information System (INIS)

    Fouad, F.M.; MacIntyre, W.J.; Tarazi, R.C.

    1981-01-01

    Cardiopulmonary blood volume (CPV) and mean pulmonary transit time (MTT) determined by radionuclide measurements (Tc-99m HSA) were compared with values obtained from simultaneous dye-dilution (DD) studies (indocyanine green). The mean transit time was obtained from radionuclide curves by two methods: the peak-to-peak time and the interval between the two centroids determined from the right and left-ventricular time-concentration curves. Correlation of dye-dilution MTT and peak-to-peak time was significant (r = 0.79, p < 0.001), but its correlation with centroid-derived values was better (r = 0.86, p < 0.001). CPV values (using the centroid method for radionuclide technique) correlated significantly with values derived from dye-dilution curves (r = 0.74, p < 0.001). Discrepancies between the two were greater the more rapid the circulation (r = 0.61, p < 0.01), suggesting that minor inaccuracies of dye-dilution methods, due to positioning or delay of the system, can become magnified in hyperkinetic conditions. The radionuclide method is simple, repeatable, and noninvasive, and it provides simultaneous evaluation of pulmonary and systemic hemodynamics. Further, calculation of the ratio of cardiopulmonary to total blood volume can be used as an index of overall venous distensibility and relocation of intravascular blood volume

  9. Interactive cervical motion kinematics: sensitivity, specificity and clinically significant values for identifying kinematic impairments in patients with chronic neck pain.

    Science.gov (United States)

    Sarig Bahat, Hilla; Chen, Xiaoqi; Reznik, David; Kodesh, Einat; Treleaven, Julia

    2015-04-01

    Chronic neck pain has been consistently shown to be associated with impaired kinematic control including reduced range, velocity and smoothness of cervical motion, that seem relevant to daily function as in quick neck motion in response to surrounding stimuli. The objectives of this study were: to compare interactive cervical kinematics in patients with neck pain and controls; to explore the new measures of cervical motion accuracy; and to find the sensitivity, specificity, and optimal cutoff values for defining impaired kinematics in those with neck pain. In this cross-section study, 33 patients with chronic neck pain and 22 asymptomatic controls were assessed for their cervical kinematic control using interactive virtual reality hardware and customized software utilizing a head mounted display with built-in head tracking. Outcome measures included peak and mean velocity, smoothness (represented by number of velocity peaks (NVP)), symmetry (represented by time to peak velocity percentage (TTPP)), and accuracy of cervical motion. Results demonstrated significant and strong effect-size differences in peak and mean velocities, NVP and TTPP in all directions excluding TTPP in left rotation, and good effect-size group differences in 5/8 accuracy measures. Regression results emphasized the high clinical value of neck motion velocity, with very high sensitivity and specificity (85%-100%), followed by motion smoothness, symmetry and accuracy. These finding suggest cervical kinematics should be evaluated clinically, and screened by the provided cut off values for identification of relevant impairments in those with neck pain. Such identification of presence or absence of kinematic impairments may direct treatment strategies and additional evaluation when needed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. Several Similarity Measures of Interval Valued Neutrosophic Soft Sets and Their Application in Pattern Recognition Problems

    Directory of Open Access Journals (Sweden)

    Anjan Mukherjee

    2014-12-01

    Full Text Available Interval valued neutrosophic soft set introduced by Irfan Deli in 2014[8] is a generalization of neutrosophic set introduced by F. Smarandache in 1995[19], which can be used in real scientific and engineering applications. In this paper the Hamming and Euclidean distances between two interval valued neutrosophic soft sets (IVNS sets are defined and similarity measures based on distances between two interval valued neutrosophic soft sets are proposed. Similarity measure based on set theoretic approach is also proposed. Some basic properties of similarity measures between two interval valued neutrosophic soft sets is also studied. A decision making method is established for interval valued neutrosophic soft set setting using similarity measures between IVNS sets. Finally an example is given to demonstrate the possible application of similarity measures in pattern recognition problems.

  11. Predicting Extubation Outcome by Cough Peak Flow Measured Using a Built-in Ventilator Flow Meter.

    Science.gov (United States)

    Gobert, Florent; Yonis, Hodane; Tapponnier, Romain; Fernandez, Raul; Labaune, Marie-Aude; Burle, Jean-François; Barbier, Jack; Vincent, Bernard; Cleyet, Maria; Richard, Jean-Christophe; Guérin, Claude

    2017-12-01

    Successful weaning from mechanical ventilation depends on the patient's ability to cough efficiently. Cough peak flow (CPF) could predict extubation success using a dedicated flow meter but required patient disconnection. We aimed to predict extubation outcome using an overall model, including cough performance assessed by a ventilator flow meter. This was a prospective observational study conducted from November 2014 to October 2015. Before and after a spontaneous breathing trial, subjects were encouraged to cough as strongly as possible before freezing the ventilator screen to assess CPF and tidal volume (V T ) in the preceding inspiration. Early extubation success rate was defined as the proportion of subjects not re-intubated 48 h after extubation. Diagnostic performance of CPF and V T was assessed by using the area under the curve of the receiver operating characteristic curve. Cut-off values for CPF and V T were defined according to median values and used to describe the performance of a predictive test combining them with risk factors of early extubation failure. Among 673 subjects admitted, 92 had a cough assessment before extubation. For the 81 subjects with early extubation success, the median CPF was -67.7 L/min, and median V T was 0.646 L. For the 11 subjects with early extubation failure, the median CPF was -57.3 L/min, and median V T was 0.448 L. Area under the curve was 0.61 (95% CI 0.37-0.83) for CPF and 0.64 (95% CI 0.42-0.84) for CPF/V T combined. After dichotomization (CPF 0.55 L), there was a synergistic effect to predict early extubation success ( P meter of an ICU ventilator was able to predict extubation success and to build a composite score to predict extubation failure. The results were close to that found in previous studies that used a dedicated flow meter. This could help to identify high-risk subjects to prevent extubation failure. (ClinicalTrials.gov registration NCT02847221.). Copyright © 2017 by Daedalus Enterprises.

  12. Measure-valued solutions to the complete Euler system revisited

    Czech Academy of Sciences Publication Activity Database

    Březina, J.; Feireisl, Eduard

    2018-01-01

    Roč. 69, č. 3 (2018), č. článku 57. ISSN 0044-2275 EU Projects: European Commission(XE) 320078 - MATHEF Institutional support: RVO:67985840 Keywords : Euler system * measure-valued solution * vanishing dissipation limit Subject RIV: BA - General Mathematics OBOR OECD: Pure mathematics Impact factor: 1.687, year: 2016 https://link.springer.com/article/10.1007/s00033-018-0951-8

  13. Demand Side Management: An approach to peak load smoothing

    Science.gov (United States)

    Gupta, Prachi

    A preliminary national-level analysis was conducted to determine whether Demand Side Management (DSM) programs introduced by electric utilities since 1992 have made any progress towards their stated goal of reducing peak load demand. Estimates implied that DSM has a very small effect on peak load reduction and there is substantial regional and end-user variability. A limited scholarly literature on DSM also provides evidence in support of a positive effect of demand response programs. Yet, none of these studies examine the question of how DSM affects peak load at the micro-level by influencing end-users' response to prices. After nearly three decades of experience with DSM, controversy remains over how effective these programs have been. This dissertation considers regional analyses that explore both demand-side solutions and supply-side interventions. On the demand side, models are estimated to provide in-depth evidence of end-user consumption patterns for each North American Electric Reliability Corporation (NERC) region, helping to identify sectors in regions that have made a substantial contribution to peak load reduction. The empirical evidence supports the initial hypothesis that there is substantial regional and end-user variability of reductions in peak demand. These results are quite robust in rapidly-urbanizing regions, where air conditioning and lighting load is substantially higher, and regions where the summer peak is more pronounced than the winter peak. It is also evident from the regional experiences that active government involvement, as shaped by state regulations in the last few years, has been successful in promoting DSM programs, and perhaps for the same reason we witness an uptick in peak load reductions in the years 2008 and 2009. On the supply side, we estimate the effectiveness of DSM programs by analyzing the growth of capacity margin with the introduction of DSM programs. The results indicate that DSM has been successful in offsetting the

  14. Automated asteroseismic peak detections

    Science.gov (United States)

    García Saravia Ortiz de Montellano, Andrés; Hekker, S.; Themeßl, N.

    2018-05-01

    Space observatories such as Kepler have provided data that can potentially revolutionize our understanding of stars. Through detailed asteroseismic analyses we are capable of determining fundamental stellar parameters and reveal the stellar internal structure with unprecedented accuracy. However, such detailed analyses, known as peak bagging, have so far been obtained for only a small percentage of the observed stars while most of the scientific potential of the available data remains unexplored. One of the major challenges in peak bagging is identifying how many solar-like oscillation modes are visible in a power density spectrum. Identification of oscillation modes is usually done by visual inspection that is time-consuming and has a degree of subjectivity. Here, we present a peak-detection algorithm especially suited for the detection of solar-like oscillations. It reliably characterizes the solar-like oscillations in a power density spectrum and estimates their parameters without human intervention. Furthermore, we provide a metric to characterize the false positive and false negative rates to provide further information about the reliability of a detected oscillation mode or the significance of a lack of detected oscillation modes. The algorithm presented here opens the possibility for detailed and automated peak bagging of the thousands of solar-like oscillators observed by Kepler.

  15. Stability of Teacher Value-Added Rankings across Measurement Model and Scaling Conditions

    Science.gov (United States)

    Hawley, Leslie R.; Bovaird, James A.; Wu, ChaoRong

    2017-01-01

    Value-added assessment methods have been criticized by researchers and policy makers for a number of reasons. One issue includes the sensitivity of model results across different outcome measures. This study examined the utility of incorporating multivariate latent variable approaches within a traditional value-added framework. We evaluated the…

  16. [Caloric value and energy allocation of Chloris virgata in northeast grassland].

    Science.gov (United States)

    Guo, J; Wang, R; Wang, W

    2001-06-01

    The rules of seasonal changes in caloric values of individual plant, stem, and leaves of Chloris virgata were similar, which had two peak values from early July to early August, and then decreased gradually. Those of inflorescence assumed U shape, and had two peak values in early August and middle September, respectively. The seasonal changes in caloric values of dead standing were irregular, and the maximum value was appeared in early August. The seasonal changes in existent energy value of the aboveground parts in Chloris virgata population presented double peak curve. The two peak values were appeared in early August and early September respectively, and the maximum value was 7381.27 kJ.m-2 in early September. The energy allocation in different seasons was leaf > stem in early July, stem > leaf > dead standing in middle July, stem > leaf > inflorescence > dead standing in August, stem > inflorescence > leaf > dead standing in early September, and stem > inflorescence > dead standing > leaf in middle September. The vertical structure of energy in the aboveground parts was that the energy value gradually increased from the earth's surface to 20 cm high, and then decreased. The maximum value, which accounted for 25.75% of energy in the aboveground parts, was appeared in the layer of 10-20 cm high. In the underground parts, the energy value progressively decreased with the increase of depth, and the maximum value, which accounted for 74.21% of energy in the underground parts, was appeared in the layer of 0-10 cm depth.

  17. Measuring energy efficiency in economics: Shadow value approach

    Science.gov (United States)

    Khademvatani, Asgar

    For decades, academic scholars and policy makers have commonly applied a simple average measure, energy intensity, for studying energy efficiency. In contrast, we introduce a distinctive marginal measure called energy shadow value (SV) for modeling energy efficiency drawn on economic theory. This thesis demonstrates energy SV advantages, conceptually and empirically, over the average measure recognizing marginal technical energy efficiency and unveiling allocative energy efficiency (energy SV to energy price). Using a dual profit function, the study illustrates how treating energy as quasi-fixed factor called quasi-fixed approach offers modeling advantages and is appropriate in developing an explicit model for energy efficiency. We address fallacies and misleading results using average measure and demonstrate energy SV advantage in inter- and intra-country energy efficiency comparison. Energy efficiency dynamics and determination of efficient allocation of energy use are shown through factors impacting energy SV: capital, technology, and environmental obligations. To validate the energy SV, we applied a dual restricted cost model using KLEM dataset for the 35 US sectors stretching from 1958 to 2000 and selected a sample of the four sectors. Following the empirical results, predicted wedges between energy price and the SV growth indicate a misallocation of energy use in stone, clay and glass (SCG) and communications (Com) sectors with more evidence in the SCG compared to the Com sector, showing overshoot in energy use relative to optimal paths and cost increases from sub-optimal energy use. The results show that energy productivity is a measure of technical efficiency and is void of information on the economic efficiency of energy use. Decomposing energy SV reveals that energy, capital and technology played key roles in energy SV increases helping to consider and analyze policy implications of energy efficiency improvement. Applying the marginal measure, we also

  18. Measuring the value of groundwater and other forms of natural capital

    Science.gov (United States)

    Fenichel, Eli P.; Abbott, Joshua K.; Bayham, Jude; Boone, Whitney; Haacker, Erin M. K.; Pfeiffer, Lisa

    2016-01-01

    Valuing natural capital is fundamental to measuring sustainability. The United Nations Environment Programme, World Bank, and other agencies have called for inclusion of the value of natural capital in sustainability metrics, such as inclusive wealth. Much has been written about the importance of natural capital, but consistent, rigorous valuation approaches compatible with the pricing of traditional forms of capital have remained elusive. We present a guiding quantitative framework enabling natural capital valuation that is fully consistent with capital theory, accounts for biophysical and economic feedbacks, and can guide interdisciplinary efforts to measure sustainability. We illustrate this framework with an application to groundwater in the Kansas High Plains Aquifer, a rapidly depleting asset supporting significant food production. We develop a 10-y time series (1996−2005) of natural capital asset prices that accounts for technological, institutional, and physical changes. Kansas lost approximately $110 million per year (2005 US dollars) of capital value through groundwater withdrawal and changes in aquifer management during the decade spanning 1996–2005. This annual loss in wealth is approximately equal to the state’s 2005 budget surplus, and is substantially more than investments in schools over this period. Furthermore, real investment in agricultural capital also declined over this period. Although Kansas’ depletion of water wealth is substantial, it may be tractably managed through careful groundwater management and compensating investments in other natural and traditional assets. Measurement of natural capital value is required to inform management and ongoing investments in natural assets. PMID:26858431

  19. Calculating meal glycemic index by using measured and published food values compared with directly measured meal glycemic index.

    Science.gov (United States)

    Dodd, Hayley; Williams, Sheila; Brown, Rachel; Venn, Bernard

    2011-10-01

    Glycemic index (GI) testing is normally based on individual foods, whereas GIs for meals or diets are based on a formula using a weighted sum of the constituents. The accuracy with which the formula can predict a meal or diet GI is questionable. Our objective was to compare the GI of meals, obtained by using the formula and by using both measured food GI and published values, with directly measured meal GIs. The GIs of 7 foods were tested in 30 healthy people. The foods were combined into 3 meals, each of which provided 50 g available carbohydrate, including a staple (potato, rice, or spaghetti), vegetables, sauce, and pan-fried chicken. The mean (95% CI) meal GIs determined from individual food GI values and by direct measurement were as follows: potato meal [predicted, 63 (56, 70); measured, 53 (46, 62)], rice meal [predicted, 51 (45, 56); measured, 38 (33, 45)], and spaghetti meal [predicted, 54 (49, 60); measured, 38 (33, 44)]. The predicted meal GIs were all higher than the measured GIs (P < 0.001). The extent of the overestimation depended on the particular food, ie, 12, 15, and 19 GI units (or 22%, 40%, and 50%) for the potato, rice, and spaghetti meals, respectively. The formula overestimated the GI of the meals by between 22% and 50%. The use of published food values also overestimated the measured meal GIs. Investigators using the formula to calculate a meal or diet GI should be aware of limitations in the method. This trial is registered with the Australian and New Zealand Clinical Trials Registry as ACTRN12611000210976.

  20. Simultaneous collection method of on-peak window image and off-peak window image in Tl-201 imaging

    International Nuclear Information System (INIS)

    Murakami, Tomonori; Noguchi, Yasushi; Kojima, Akihiro; Takagi, Akihiro; Matsumoto, Masanori

    2007-01-01

    Tl-201 imaging detects the photopeak (71 keV, in on-peak window) of characteristic X-rays of Hg-201 formed from Tl-201 decay. The peak is derived from 4 rays of different energy and emission intensity and does not follow in Gaussian distribution. In the present study, authors made an idea for the method in the title to attain the more effective single imaging, which was examined for its accuracy and reliability with phantoms and applied clinically to Tl-201 scintigraphy in a patient. The authors applied the triple energy window method for data acquisition: the energy window setting was made on Hg-201 X-rays photopeak in three of the lower (3%, L), main (72 keV, M) and upper (14%, U) windows with the gamma camera with 2-gated detector (Toshiba E. CAM/ICON). L, M and U images obtained simultaneously were then constructed to images of on-peak (L+M, Mock on-peak) and off-peak (M+U) window settings for evaluation. Phantoms for line source with Tl-201-containing swab and for multi-defect with acrylic plate containing Tl-201 solution were imaged in water. The female patient with thyroid cancer was subjected to preoperative scintigraphy under the defined conditions. Mock on-, off-peak images were found to be equivalent to the true (ordinary, clinical) on-, off-peak ones, and the present method was thought usable for evaluation of usefulness of off-peak window data. (R.T.)

  1. Cervical vertebral maturation method and mandibular growth peak: a longitudinal study of diagnostic reliability.

    Science.gov (United States)

    Perinetti, Giuseppe; Primozic, Jasmina; Sharma, Bhavna; Cioffi, Iacopo; Contardo, Luca

    2018-03-28

    The capability of the cervical vertebral maturation (CVM) method in the identification of the mandibular growth peak on an individual basis remains undetermined. The diagnostic reliability of the six-stage CVM method in the identification of the mandibular growth peak was thus investigated. From the files of the Oregon and Burlington Growth Studies (data obtained between early 1950s and middle 1970s), 50 subjects (26 females, 24 males) with at least seven annual lateral cephalograms taken from 9 to 16 years were identified. Cervical vertebral maturation was assessed according to the CVM code staging system, and mandibular growth was defined as annual increments in Co-Gn distance. A diagnostic reliability analysis was carried out to establish the capability of the circumpubertal CVM stages 2, 3, and 4 in the identification of the imminent mandibular growth peak. Variable durations of each of the CVM stages 2, 3, and 4 were seen. The overall diagnostic accuracy values for the CVM stages 2, 3, and 4 were 0.70, 0.76, and 0.77, respectively. These low values appeared to be due to false positive cases. Secular trends in conjunction with the use of a discrete staging system. In most of the Burlington Growth Study sample, the lateral head film at age 15 was missing. None of the CVM stages 2, 3, and 4 reached a satisfactorily diagnostic reliability in the identification of imminent mandibular growth peak.

  2. Peak stresses shift from femoral tunnel aperture to tibial tunnel aperture in lateral tibial tunnel ACL reconstructions: a 3D graft-bending angle measurement and finite-element analysis.

    Science.gov (United States)

    Van Der Bracht, Hans; Tampere, Thomas; Beekman, Pieter; Schepens, Alexander; Devriendt, Wouter; Verdonk, Peter; Victor, Jan

    2018-02-01

    To investigate the effect of tibial tunnel orientation on graft-bending angle and stress distribution in the ACL graft. Eight cadaveric knees were scanned in extension, 45°, 90°, and full flexion. 3D reconstructions with anatomically placed anterior cruciate ligament (ACL) grafts were constructed with Mimics 14.12 ® . 3D graft-bending angles were measured for classic medial tibial tunnels (MTT) and lateral tibial tunnels (LTT) with different drill-guide angles (DGA) (45°, 55°, 65°, and 75°). A pivot shift was performed on 1 knee in a finite-element analysis. The peak stresses in the graft were calculated for eight different tibial tunnel orientations. In a classic anatomical ACL repair, the largest graft-bending angle and peak stresses are seen at the femoral tunnel aperture. The use of a different DGA at the tibial side does not change the graft-bending angle at the femoral side or magnitude of peak stresses significantly. When using LTT, the largest graft-bending angles and peak stresses are seen at the tibial tunnel aperture. In a classic anatomical ACL repair, peak stresses in the ACL graft are found at the femoral tunnel aperture. When an LTT is used, peak stresses are similar compared to classic ACL repairs, but the location of the peak stress will shift from the femoral tunnel aperture towards the tibial tunnel aperture. the risk of graft rupture is similar for both MTTs and LTTs, but the location of graft rupture changes from the femoral tunnel aperture towards the tibial tunnel aperture, respectively. I.

  3. Analysis of the diffraction peaks in the ZrCr2 system

    International Nuclear Information System (INIS)

    Quiroga, A.A.; Esquivel, M.R.

    2009-01-01

    In this work, the crystalline structures of Cr and Zr are characterized by X-ray Diffraction (XRD). The diffraction peaks are simulated using a numerical convolution of the Gauss and Lorentz functions. The simulation of the model is verified using empirical measurements of the diffraction peaks. From these results, the microstructure parameters of Zr and Cr are obtained: crystallite size (d) and strain (s). The advances obtained are used in the design of the synthesis of AB 2 intermetallics applied to thermal compression of hydrogen (Tch). (author)

  4. Debate Regarding Measuring Accounting Value: Historical Cost against Fair Value

    OpenAIRE

    Victor Munteanu; Marilena Zuca

    2015-01-01

    The transition from historical cost to fair value represents an option with major implications in accounting, because it is a complex process that requires tuning to today’s trends of national and global economy. We can state that with all the advantages of using historical cost it has its limitations and it is” getting old”. That doesn’t mean that will be abandoned but substituted when it is needed with another value. At present, the lack of historical value is inconceivable; many practit...

  5. Measurement of a Peak in the Cosmic Microwave Background Power Spectrum from the North American test flight of BOOMERANG

    CERN Document Server

    Mauskopf, P D; De Bernardis, P; Bock, J J; Borrill, J; Boscaleri, A; Crill, B P; De Gasperis, G; De Troia, G; Farese, P; Ferreira, P G; Ganga, K; Giacometti, M; Hanany, S; Hristov, V V; Iacoangeli, A; Jaffe, A H; Lange, A E; Lee, A T; Masi, S; Melchiorri, A; Melchiorri, F; Miglio, L; Montroy, T; Netterfield, C B; Pascale, E; Piacentini, F; Richards, P L; Romeo, G; Ruhl, J E; Scannapieco, E S; Scaramuzzi, F; Stompor, R; Vittorio, N

    2000-01-01

    We describe a measurement of the angular power spectrum of anisotropies in the Cosmic Microwave Background (CMB) from 0.3 degrees to ~10 degrees from the North American test flight of the BOOMERANG experiment. BOOMERANG is a balloon-borne telescope with a bolometric receiver designed to map CMB anisotropies on a Long Duration Balloon flight. During a 6-hour test flight of a prototype system in 1997, we mapped > 200 square degrees at high galactic latitudes in two bands centered at 90 and 150 GHz with a resolution of 26 and 16.6 arcmin FWHM respectively. Analysis of the maps gives a power spectrum with a peak at angular scales of ~1 degree with an amplitude ~70 uK.

  6. Use of the mathematical modelling method for the investigation of dynamic characteristics of acoustical measuring instruments

    Science.gov (United States)

    Vasilyev, Y. M.; Lagunov, L. F.

    1973-01-01

    The schematic diagram of a noise measuring device is presented that uses pulse expansion modeling according to the peak or any other measured values, to obtain instrument readings at a very low noise error.

  7. MCNP simulation of the influence of the external moisture on low calorific value in the coal quality analysis by neutron

    International Nuclear Information System (INIS)

    Liu Dekun; Zhang Hongyu; Zhang Lihong; Dong Huan; Gu Deshan

    2012-01-01

    An important index in assessment of coal quality is low calorific value. Using neutron to analysis coal quality, the more the coal moisture content, especially the increasing of external moisture will reduce the low calorific value. The principle of coal quality analysis by neutron prompt Gamma-ray is introduced. The influence of the gamma count of the carbon element peak with increasing external moisture in coal samples was simulated using MCNP code. And discussed the reasons how external moisture content influence the calorific value. Simulation results indicate that with the increasing of external moisture in the coal samples, the gamma count of the carbon element peak dwindling, and the low calorific value reducing. The conclusion is : using neutrons method to analysis coal quality, the more external moisture content, the larger error of the measurement results of the carbon element, and will influence the calculation accuracy of the low calorific value. (authors)

  8. Reference values and clinical application of magnetic peripheral nerve stimulation in cats

    NARCIS (Netherlands)

    Van Soens, Iris; Struys, Michel M. R. F.; Bhatti, Sofie F. M.; Van Ham, Luc M. L.

    Magnetic stimulation of radial (RN) and sciatic (SN) nerves was performed bilaterally in 40 healthy cats. Reference values for onset latency and peak-to-peak amplitude of magnetic motor evoked potentials (MMEPs) were obtained and compared with values of electric motor evoked potentials (EMEPs) in

  9. Computing interval-valued reliability measures: application of optimal control methods

    DEFF Research Database (Denmark)

    Kozin, Igor; Krymsky, Victor

    2017-01-01

    The paper describes an approach to deriving interval-valued reliability measures given partial statistical information on the occurrence of failures. We apply methods of optimal control theory, in particular, Pontryagin’s principle of maximum to solve the non-linear optimisation problem and derive...... the probabilistic interval-valued quantities of interest. It is proven that the optimisation problem can be translated into another problem statement that can be solved on the class of piecewise continuous probability density functions (pdfs). This class often consists of piecewise exponential pdfs which appear...... as soon as among the constraints there are bounds on a failure rate of a component under consideration. Finding the number of switching points of the piecewise continuous pdfs and their values becomes the focus of the approach described in the paper. Examples are provided....

  10. Uniqueness plots: A simple graphical tool for identifying poor peak fits in X-ray photoelectron spectroscopy

    Science.gov (United States)

    Singh, Bhupinder; Diwan, Anubhav; Jain, Varun; Herrera-Gomez, Alberto; Terry, Jeff; Linford, Matthew R.

    2016-11-01

    Peak fitting is an essential part of X-ray photoelectron spectroscopy (XPS) narrow scan analysis, and the Literature contains both good and bad examples of peak fitting. A common cause of poor peak fitting is the inclusion of too many fit parameters, often without a sound chemical and/or physical basis for them, and/or the failure to reasonably constrain them. Under these conditions, fit parameters are often correlated, and therefore lacking in statistical meaning. Here we introduce the uniqueness plot as a simple graphical tool for identifying bad peak fits in XPS, i.e., fit parameter correlation. These plots are widely used in spectroscopic ellipsometry. We illustrate uniqueness plots with two data sets: a C 1s narrow scan from ozone-treated carbon nanotube forests and an Si 2p narrow scan from an air-oxidized silicon wafer. For each fit, we consider different numbers of parameters and constraints on them. As expected, the uniqueness plots are parabolic when fewer fit parameters and/or more constraints are applied. However, they fan out and eventually become horizontal lines as more unconstrained parameters are included in the fits. Uniqueness plots are generated by plotting the chi squared (χ2) value for a fit vs. a systematically varied value of a parameter in the fit. The Abbe criterion is also considered as a figure of merit for uniqueness plots in the Supporting Information. We recommend that uniqueness plots be used by XPS practitioners for identifying inappropriate peak fits.

  11. Difference in peak weight transfer and timing based on golf handicap.

    Science.gov (United States)

    Queen, Robin M; Butler, Robert J; Dai, Boyi; Barnes, C Lowry

    2013-09-01

    Weight shift during the golf swing has been a topic of discussion among golf professionals; however, it is still unclear how weight shift varies in golfers of different performance levels. The main purpose of this study was to examine the following: (a) the changes in the peak ground reaction forces (GRF) and the timing of these events between high (HHCP) and low handicap (LHCP) golfers and (b) the differences between the leading and trailing legs. Twenty-eight male golfers were recruited and divided based on having an LHCP 9. Three-dimensional GRF peaks and the timing of the peaks were recorded bilaterally during a golf swing. The golf swing was divided into different phases: (a) address to the top of the backswing, (b) top of the backswing to ball contact, and (c) ball contact to the end of follow through. Repeated measures analyses of variance (α = 0.05) were completed for each study variable: the magnitude and the timing of peak vertical GRF, peak lateral GRF, and peak medial GRF (α = 0.05). The LHCP group had a greater transfer of vertical force from the trailing foot to the leading foot in phase 2 than the HHCP group. The LHCP group also demonstrated earlier timing of peak vertical force throughout the golf swing than the HHCP group. The LHCP and HHCP groups demonstrated different magnitudes of peak lateral force. The LHCP group had an earlier timing of peak lateral GRF in phase 2 and earlier timing of peak medial GRF in phases 1 and 2 than the HHCP group. In general, LHCP golfers demonstrated greater and earlier force generation than HHCP golfers. It may be relevant to consider both the magnitude of the forces and the timing of these events during golf-specific training to improve performance. These data reveal weight shifting differences that can be addressed by teaching professionals to help their students better understand weight transfer during the golf swing to optimize performance.

  12. Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE).

    Science.gov (United States)

    Shen, Yang; Su, Xiangjian; Liu, Xiu; Miao, Huamao; Fang, Xuejun; Zhou, Xingtao

    2016-11-18

    Corneal biomechanical properties are always compromised after corneal refractive surgeries thus leading to underestimated intraocular pressure (IOP) that complicates the management of IOP. We investigated the changes in postoperative baseline of IOP values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology (CST) in the early phase after small incision lenticule extraction (SMILE). Twenty-two eyes (-6.76 ± 1.39D) of 22 moderate and high myopes, (28.36 ± 7.14 years, 12 male and 10 female) were involved in this prospective study. IOP values were measured using a non-contact tomometer (NCT-IOP), an ocular response analyzer (corneal-compensated IOP, IOPcc and Goldmann-correlated IOP, IOPg) and a Corvis scheimpflug technology tonometer (CST-IOP) preoperatively, at 20 min and 24 h, postoperatively. Repeated measures analysis of variance (RM-ANOVA), Pearson's correlation analysis and multiple linear regression models (stepwise) were performed. Cut-off P values were 0.05. Except for IOPcc, NCT-IOP, IOPg, and CST-IOP values significantly decreased after SMILE procedure (All P values 0.05). Multiple linear regression models (stepwise) showed that the practical post-operative IOP value was the main predictor of the theoretical post-operative NCT-IOP, IOPcc and IOPg values (all P values <0.001). The postoperative applanation time 1 (AT1) value (B = 8.079, t = 4.866, P < 0.001), preoperative central corneal thickness (CCT) value (B = 0.035, t = 2.732, P = 0.014) and postoperative peak distance (PD) value (B = 0.515, t = 2.176, P = 0.043) were the main predictors of the theoretical post-operative CST-IOP value. IOP values are underestimated when assessed after SMILE by using NCT-IOP, IOPg and CST-IOP. The practical postoperative IOPcc value and theoretical post-operative CST-IOP value may be more preferable for IOP assessment in the early phase after SMILE. Current Controlled

  13. The Gas Sampling Interval Effect on V˙O2peak Is Independent of Exercise Protocol.

    Science.gov (United States)

    Scheadler, Cory M; Garver, Matthew J; Hanson, Nicholas J

    2017-09-01

    There is a plethora of gas sampling intervals available during cardiopulmonary exercise testing to measure peak oxygen consumption (V˙O2peak). Different intervals can lead to altered V˙O2peak. Whether differences are affected by the exercise protocol or subject sample is not clear. The purpose of this investigation was to determine whether V˙O2peak differed because of the manipulation of sampling intervals and whether differences were independent of the protocol and subject sample. The first subject sample (24 ± 3 yr; V˙O2peak via 15-breath moving averages: 56.2 ± 6.8 mL·kg·min) completed the Bruce and the self-paced V˙O2max protocols. The second subject sample (21.9 ± 2.7 yr; V˙O2peak via 15-breath moving averages: 54.2 ± 8.0 mL·kg·min) completed the Bruce and the modified Astrand protocols. V˙O2peak was identified using five sampling intervals: 15-s block averages, 30-s block averages, 15-breath block averages, 15-breath moving averages, and 30-s block averages aligned to the end of exercise. Differences in V˙O2peak between intervals were determined using repeated-measures ANOVAs. The influence of subject sample on the sampling effect was determined using independent t-tests. There was a significant main effect of sampling interval on V˙O2peak (first sample Bruce and self-paced V˙O2max P sample Bruce and modified Astrand P sampling intervals followed a similar pattern for each protocol and subject sample, with 15-breath moving average presenting the highest V˙O2peak. The effect of manipulating gas sampling intervals on V˙O2peak appears to be protocol and sample independent. These findings highlight our recommendation that the clinical and scientific community request and report the sampling interval whenever metabolic data are presented. The standardization of reporting would assist in the comparison of V˙O2peak.

  14. Statistical analysis of the low-temperature dislocation peak of internal friction (Bordoni peak) in nanostructured copper

    International Nuclear Information System (INIS)

    Vatazhuk, E.N.; Natsik, V.D.

    2011-01-01

    The temperature-frequency dependence of internal friction in the nanostructured samples of Cu and fibred composite C-32 vol.%Nb with the sizes of structure fragments approx 200 nm is analyzed. Experiments are used as initial information for such analysis. The characteristic for the heavily deformed copper Bordoni peak, located nearby a temperature 90 K, was recorded on temperature dependence of vibration decrement (frequencies 73-350 kHz) in previous experiments. The peak is due to the resonance interaction of sound with the system of thermal activated relaxators, and its width considerably greater in comparison with the width of standard internal friction peak with the single relaxation time. Statistical analysis of the peak is made in terms of assumption that the reason of broadening is random activation energy dispersion of relaxators as a result of intense distortion of copper crystal structure. Good agreement of experimental data and Seeger theory considers thermal activated paired kinks at linear segments of dislocation lines, placed in potential Peierls relief valley, as relaxators of Bordoni peak, was established. It is shown that the registered peak height in experiment correspond to presence at the average one dislocation segment in the interior of crystalline grain with size of 200 nm. Empirical estimates for the critical Peierls stress σp ∼ 2x10 7 Pa and integrated density of the interior grain dislocations ρ d ∼ 10 13 m -2 are made. Nb fibers in the composite Cu-Nb facilitate to formation of nanostructured copper, but do not influence evidently on the Bordoni peak.

  15. Vector-valued measure and the necessary conditions for the optimal control problems of linear systems

    International Nuclear Information System (INIS)

    Xunjing, L.

    1981-12-01

    The vector-valued measure defined by the well-posed linear boundary value problems is discussed. The maximum principle of the optimal control problem with non-convex constraint is proved by using the vector-valued measure. Especially, the necessary conditions of the optimal control of elliptic systems is derived without the convexity of the control domain and the cost function. (author)

  16. Dollar$ & $en$e. Part IV: Measuring the value of people, structural, and customer capital.

    Science.gov (United States)

    Wilkinson, I

    2001-01-01

    In Part I of this series, I introduced the concept of memes (1). Memes are ideas or concepts, the information world equivalent of genes. The goal of this series of articles is to infect you with my memes, so that you will assimilate, translate, and express them. We discovered that no matter what our area of expertise or "-ology," we all are in the information business. Our goal is to be in the wisdom business. We saw that when we convert raw data into wisdom we are moving along a value chain. Each step in the chain adds a different amount of value to the final product: timely, relevant, accurate, and precise knowledge which can then be applied to create the ultimate product in the value chain: wisdom. In Part II of this series, I infected you with a set of memes for measuring the cost of adding value (2). In Part III of this series, I infected you with a new set of memes for measuring the added value of knowledge, i.e., intellectual capital (3). In Part IV of this series, I will infect you with memes for measuring the value of people, structural, and customer capital.

  17. Economic effects of peak oil

    International Nuclear Information System (INIS)

    Lutz, Christian; Lehr, Ulrike; Wiebe, Kirsten S.

    2012-01-01

    Assuming that global oil production peaked, this paper uses scenario analysis to show the economic effects of a possible supply shortage and corresponding rise in oil prices in the next decade on different sectors in Germany and other major economies such as the US, Japan, China, the OPEC or Russia. Due to the price-inelasticity of oil demand the supply shortage leads to a sharp increase in oil prices in the second scenario, with high effects on GDP comparable to the magnitude of the global financial crises in 2008/09. Oil exporting countries benefit from high oil prices, whereas oil importing countries are negatively affected. Generally, the effects in the third scenario are significantly smaller than in the second, showing that energy efficiency measures and the switch to renewable energy sources decreases the countries' dependence on oil imports and hence reduces their vulnerability to oil price shocks on the world market. - Highlights: ► National and sectoral economic effects of peak oil until 2020 are modelled. ► The price elasticity of oil demand is low resulting in high price fluctuations. ► Oil shortage strongly affects transport and indirectly all other sectors. ► Global macroeconomic effects are comparable to the 2008/2009 crisis. ► Country effects depend on oil imports and productivity, and economic structures.

  18. Determination of temperature dependant viscosity values of lubricants via simultaneous measurements of refractive index

    International Nuclear Information System (INIS)

    Yaltkaya, S.

    2005-01-01

    Viscosity is one of the most important parameter in rheological and tribological properties of fluids. The objective of this study is to obtain the viscosity values from the simultaneous refractive-index measurements of lubricants, simply by dipping the fiber-optic probe into the oil to be measured. Due to the fact that these parameters are temperature dependent, within the interval under consideration, oil heated up steadily while measuring the viscosity and refractive index at the same time. The refractive index sensor, the digital viscometer and the thermometer were connected to a PC via an analog to digital converter and the values were acquired at the same time. The fiber optic refractive index sensor has been designed in our laboratory. By utilising Fresnel's fundamental reflection law, the intensity of reflected light from boundary surface (optic fiber core-motor oil) was measured at 660 nm wavelength and then refractive index of the oil was calculated. The derived refractive index values were converted viscosity values that acquired by using the calibration equation. The viscometer, used during the study, was the rotational Brookfield type

  19. Examining the Perceived Value of Integration of Earned Value Management with Risk Management-Based Performance Measurement Baseline

    Science.gov (United States)

    Shah, Akhtar H.

    2014-01-01

    Many projects fail despite the use of evidence-based project management practices such as Performance Measurement Baseline (PMB), Earned Value Management (EVM) and Risk Management (RM). Although previous researchers have found that integrated project management techniques could be more valuable than the same techniques used by themselves, these…

  20. The Value of Value

    DEFF Research Database (Denmark)

    Sørensen, Asger

    parts of business ethics given prominence to especially one term, namely `value'. The question that interests me is the following: What does the articulation of ethics and morality in terms of values mean for ethics and morality as such. Or, to put the question in a more fashionably way: What......As a social scientist of ethics and morality, Luhmann has noticed the ethical wave that has recently swept across the western world, and states that this particular kind of wave seems to have a wavelength of about one hundred years (cf. Luhmann 1989: 9 ff.). Even though the frequency...... and the regularity of such a phenomenon is both hard to verify and, if true, difficult to explain, it seems fair to say that since the Enlightenment, an approaching fin-de-siecle has brought an increased interest in matters concerning morality and ethics.1 The present peak has in public-political discourse and some...

  1. Relative thermoluminescent efficiencies proton/gamma and helium/gamma of peaks of high temperature in TLD-100 dosemeters; Eficiencias termoluminiscentes relativas proton/gamma y helio/gamma de picos de alta temperatura en dosimetros TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Flores M, E. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico)

    2007-07-01

    The increase of the applications of ion beams in radiotherapy treatments has generated interest in the study of the thermoluminescent materials (TL) that allow to determine the applied doses. A way to quantify the TL response from these materials to ions is by means of the relative thermoluminescent efficiency. In the group of Thermoluminescent dosimetry of the Institute of Physics of the UNAM (IFUNAM) the thermoluminescent response of the TLD-100 dosemeters has been studied, which present a glow curve characteristic with several peaks that correspond to traps and luminescent centers in the material. The stable peaks know each other as 4, 5, 6a, 6b, 7, 8, 9 and 10. The efficiencies should be measured using the response so much to the radiation of interest (in this case protons and helium ions) as the response to gamma radiation. In previous works with ions of low energy taken place in the Pelletron accelerator of the IFUNAM was only measured the TL efficiency for the peak 5 and the total signal. It had not been possible to measure the efficiency of the peaks of high temperature (6a-10) because, for the gamma radiation, the peaks of high temperature show very small signals; however, recently Massillon carries out measures of efficiency TL of peaks of high temperature for ions of intermediate energy using a protocol special of reading and of deconvolution that allows to measure the signals coming from the peaks of high temperature. In this work is implemented this same protocol to complete the study of TL efficiencies at low energy of protons and helium and to determine if the values of efficiency depend on the used reading protocol. For it is reported it measures of the relative efficiency of the peaks of high temperature from the TLD-100 exposed to protons of 1.5 MeV and nuclei of helium of 3 and 7.5 MeV. (Author)

  2. Measuring the added value of workplace change. Comparison between Theory and Practice

    NARCIS (Netherlands)

    van der Voordt, Theo; Riratanaphong, C.

    2014-01-01

    Purpose: Worldwide organisations have introduced more flexibility in place, time and ways of working. In order to be able to define the added value of workplace change, a clear performance measurement system is needed to measure organisational performance in connection to real estate before and

  3. Measuring Corporate Sustainability and Environmental, Social, and Corporate Governance Value Added

    Directory of Open Access Journals (Sweden)

    Alena Kocmanová

    2016-09-01

    Full Text Available The aim of the paper is to propose a model for measuring sustainable value which would complexly assess environmental, social, and corporate governance contribution to value creation. In the paper the concept of the Sustainable Environmental, Social and Corporate Governance Value Added is presented. The Sustainable Environmental, Social and Corporate Governance Value Added is based on the Sustainable Value Added model and combines weighted environmental, social, and corporate governance indicators with their benchmarks determined by Data Envelopment Analysis. Benchmark values of indicators were set for each company separately and determine the optimal combination of environmental, social, and corporate governance inputs to economic outcomes. The Sustainable Environmental, Social and Corporate Governance Value Added methodology is applied on real-life corporate data and presented through a case study. The value added of most of the selected companies was negative, even though economic indicators of all of them are positive. The Sustainable Environmental, Social and Corporate Governance Value Added is intended to help owners, investors, and other stakeholders in their decision-making and sustainability assessment. The use of environmental, social, and corporate governance factors helps identify the company’s strengths and weaknesses, and provides a more sophisticated insight into it than the one-dimensional methods based on economic performance alone.

  4. Measuring the value of nonwage employee benefits: building a model of the relation between benefit satisfaction and value.

    Science.gov (United States)

    Weathington, Bart L; Jones, Allan P

    2006-11-01

    Researchers have commonly assumed benefits that employees view as more valuable have a greater influence on their attitudes and behaviors. Researchers have used 2 common methods to measure benefit value: attaching a monetary value to benefits and using self-reports of benefit importance. The present authors propose that the 2 approaches are conceptually distinct and have different implications. They use a social exchange perspective to justify this distinction and integrate both approaches and benefit satisfaction into a more comprehensive model of benefit perception. Results suggest that both measures have practical applications depending on the nature of the exchange relationship between the organization and employees. However, this relationship depends on the specific benefit and on employee satisfaction with that benefit. Some benefits lend themselves to a monetary estimate, whereas others lend themselves more to a nonmonetary valuation.

  5. A non-linear algorithm for current signal filtering and peak detection in SiPM

    International Nuclear Information System (INIS)

    Putignano, M; Intermite, A; Welsch, C P

    2012-01-01

    Read-out of Silicon Photomultipliers is commonly achieved by means of charge integration, a method particularly susceptible to after-pulsing noise and not efficient for low level light signals. Current signal monitoring, characterized by easier electronic implementation and intrinsically faster than charge integration, is also more suitable for low level light signals and can potentially result in much decreased after-pulsing noise effects. However, its use is to date limited by the need of developing a suitable read-out algorithm for signal analysis and filtering able to achieve current peak detection and measurement with the needed precision and accuracy. In this paper we present an original algorithm, based on a piecewise linear-fitting approach, to filter the noise of the current signal and hence efficiently identifying and measuring current peaks. The proposed algorithm is then compared with the optimal linear filtering algorithm for time-encoded peak detection, based on a moving average routine, and assessed in terms of accuracy, precision, and peak detection efficiency, demonstrating improvements of 1÷2 orders of magnitude in all these quality factors.

  6. Debate Regarding Measuring Accounting Value: Historical Cost against Fair Value

    Directory of Open Access Journals (Sweden)

    Victor Munteanu

    2015-12-01

    Full Text Available The transition from historical cost to fair value represents an option with major implications in accounting, because it is a complex process that requires tuning to today’s trends of national and global economy. We can state that with all the advantages of using historical cost it has its limitations and it is” getting old”. That doesn’t mean that will be abandoned but substituted when it is needed with another value. At present, the lack of historical value is inconceivable; many practitioners consider it to be the best method to evaluate assets.

  7. Influence Of Number Of Pregnancies In Peak Expiratory Flow And Body Composition Of Pregnant Women

    Directory of Open Access Journals (Sweden)

    Andrea Carla Brandao da Costa Santos

    2017-06-01

    Full Text Available Objectives: to describe and compare the mean values of the body composition and the peak expiratory flow (PEF in primigravidae and multigravidae and, to determine its correlation with obstetric, anthropometric and body composition variables. Method: it was performed a cross-sectional study of 120 healthy pregnant women at low risk, including 77 primigravidae and 43 multigravidae. The PEF was measured by spirometry and the body composition by multisegmental electrical impedance. The unpaired t test was used to compare the groups and the Pearson correlation test was used to determine the association between PEF and independent variables. A multiple linear regression was used to estimate the relationship between the dependent variable, the PEF and the independent variables. Results: the body composition variables in multigravidae women showed higher values compared to the primigravidae, being statistically significant, except for fat mass. In primigravidae, the PEF was correlated significantly with maternal age and height. In multigravidae, the PEF was correlated with maternal age, height, pre-pregnancy and current weight, total body water, extracellular water, fat mass, lean mass and fat-free mass. A Multiple linear regression analysis showed that, in primigravidae, height and maternal age were associated with PEF, being responsible for explaining 14.5% of its variability. The current weight and the maternal age explained 42.3% of peak flow variability in multigravidae. Conclusion: The PEF seemed to be influenced by the number of pregnancies. Changes were observed in relation to the body composition, as it was evidenced in correlation with the PEF in multigravidae women. Keywords: Pregnancy. Spirometry. Weight gain.

  8. Method and apparatus for current-output peak detection

    Science.gov (United States)

    De Geronimo, Gianluigi

    2017-01-24

    A method and apparatus for a current-output peak detector. A current-output peak detector circuit is disclosed and works in two phases. The peak detector circuit includes switches to switch the peak detector circuit from the first phase to the second phase upon detection of the peak voltage of an input voltage signal. The peak detector generates a current output with a high degree of accuracy in the second phase.

  9. Redshift space correlations and scale-dependent stochastic biasing of density peaks

    Science.gov (United States)

    Desjacques, Vincent; Sheth, Ravi K.

    2010-01-01

    We calculate the redshift space correlation function and the power spectrum of density peaks of a Gaussian random field. Our derivation, which is valid on linear scales k≲0.1hMpc-1, is based on the peak biasing relation given by Desjacques [Phys. Rev. DPRVDAQ1550-7998, 78, 103503 (2008)10.1103/PhysRevD.78.103503]. In linear theory, the redshift space power spectrum is Ppks(k,μ)=exp⁡(-f2σvel2k2μ2)[bpk(k)+bvel(k)fμ2]2Pδ(k), where μ is the angle with respect to the line of sight, σvel is the one-dimensional velocity dispersion, f is the growth rate, and bpk(k) and bvel(k) are k-dependent linear spatial and velocity bias factors. For peaks, the value of σvel depends upon the functional form of bvel. When the k dependence is absent from the square brackets and bvel is set to unity, the resulting expression is assumed to describe models where the bias is linear and deterministic, but the velocities are unbiased. The peak model is remarkable because it has unbiased velocities in this same sense—peak motions are driven by dark matter flows—but, in order to achieve this, bvel must be k dependent. We speculate that this is true in general: k dependence of the spatial bias will lead to k dependence of bvel even if the biased tracers flow with the dark matter. Because of the k dependence of the linear bias parameters, standard manipulations applied to the peak model will lead to k-dependent estimates of the growth factor that could erroneously be interpreted as a signature of modified dark energy or gravity. We use the Fisher formalism to show that the constraint on the growth rate f is degraded by a factor of 2 if one allows for a k-dependent velocity bias of the peak type. Our analysis also demonstrates that the Gaussian smoothing term is part and parcel of linear theory. We discuss a simple estimate of nonlinear evolution and illustrate the effect of the peak bias on the redshift space multipoles. For k≲0.1hMpc-1, the peak bias is deterministic but k

  10. The Peak Pairs algorithm for strain mapping from HRTEM images

    Energy Technology Data Exchange (ETDEWEB)

    Galindo, Pedro L. [Departamento de Lenguajes y Sistemas Informaticos, CASEM, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain)], E-mail: pedro.galindo@uca.es; Kret, Slawomir [Institute of Physics, PAS, AL. Lotnikow 32/46, 02-668 Warsaw (Poland); Sanchez, Ana M. [Departamento de Ciencia de los Materiales e Ing. Metalurgica y Q. Inorganica, Facultad de Ciencias, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain); Laval, Jean-Yves [Laboratoire de Physique du Solide, UPR5 CNRS-ESPCI, Paris (France); Yanez, Andres; Pizarro, Joaquin; Guerrero, Elisa [Departamento de Lenguajes y Sistemas Informaticos, CASEM, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain); Ben, Teresa; Molina, Sergio I. [Departamento de Ciencia de los Materiales e Ing. Metalurgica y Q. Inorganica, Facultad de Ciencias, Universidad de Cadiz, Pol. Rio San Pedro s/n. 11510, Puerto Real, Cadiz (Spain)

    2007-11-15

    Strain mapping is defined as a numerical image-processing technique that measures the local shifts of image details around a crystal defect with respect to the ideal, defect-free, positions in the bulk. Algorithms to map elastic strains from high-resolution transmission electron microscopy (HRTEM) images may be classified into two categories: those based on the detection of peaks of intensity in real space and the Geometric Phase approach, calculated in Fourier space. In this paper, we discuss both categories and propose an alternative real space algorithm (Peak Pairs) based on the detection of pairs of intensity maxima in an affine transformed space dependent on the reference area. In spite of the fact that it is a real space approach, the Peak Pairs algorithm exhibits good behaviour at heavily distorted defect cores, e.g. interfaces and dislocations. Quantitative results are reported from experiments to determine local strain in different types of semiconductor heterostructures.

  11. Using elastic peak electron spectroscopy for enhanced depth resolution in sputter profiling

    International Nuclear Information System (INIS)

    Hofmann, S.; Kesler, V.

    2002-01-01

    Elastic peak electron spectroscopy (EPES) is an alternative to AES in sputter depth profiling of thin film structures. In contrast to AES, EPES depth profiling is not influenced by chemical effects. The high count rate ensures a good signal to noise ratio, that is lower measurement times and/or higher precision. In addition, because of the elastically scattered electrons travel twice through the sample, the effective escape depth is reduced, an important factor for the depth resolution function. Thus, the depth resolution is increased. EPES depth profiling was successfully applied to a Ge/Si multilayer structure. For an elastic peak energy of 1.0 keV the information depth is considerably lower (0.8 nm) as compared to the Ge (LMM, 1147 eV) peak (1.6 nm) used in AES depth profiling, resulting in a respectively improved depth resolution for EPES profiling under otherwise similar profiling conditions. EPES depth profiling is successfully applied to measure small diffusion lengths at Ge/Si interfaces of the order of 1 nm. (Authors)

  12. Accurate Q value measurements for fundamental physics studies at JYFLTRAP

    Energy Technology Data Exchange (ETDEWEB)

    Eronen, T., E-mail: tommi.o.eronen@jyu.fi; Kolhinen, V. S. [University of Jyvaeskylae (Finland); Collaboration: JYFLTRAP collaboration

    2011-07-15

    We have measured several Q values at JYFLTRAP for superallowed {beta} decays that contribute to testing the Standard Model and candidate nuclei that one could use for the search of neutrinoless double-{beta} decay. These results play important roles in the research of fundamental physics that have scopes beyond Standard Model.

  13. Can semiquantitative measurements of SUVmax and cut-off values differentiate colorectal malignant from benign lessions?

    DEFF Research Database (Denmark)

    Nguyen, Tram; Hess, Søren; Petersen, Henrik

    2017-01-01

    , which also precludes a clinically significant cut-off value. The same applies to SUVpeak and SUVmean while TLG measures may be more indicative. CONCLUSION: Semi-quantitative measurements of SUVmax and cut-off values proved inadequate for differentiating colorectal malignancies from benign findings...

  14. Effect of overlapping on location of peaks in qualitative X-ray fluorescent analysis

    International Nuclear Information System (INIS)

    Jordanov, J.; Stefanov, R.; Tsanov, T.; Jordanov, N.

    1982-01-01

    To determine the location of the maxima in spectra without resorting to the comparatively complex Fourier-analysis apparatus it is proposed to take into account the overlapping of two adjacent peaks. A formula for the correction of the locations of overlapping maxima with an infinitely small step has been obtained and it is recommended when using X-ray apparatus with great resolution. With flat crystal-analyser apparata, which has a comparatively small resolution, a considerable number of maxima are obtained from the overlapping of at least two adjacent peaks. For that case another formula for the estimation of the shift of the maxima's location from their tabular values is proposed. (authors)

  15. The influence of dose on the kinetic parameters and dosimetric features of the main thermoluminescence glow peak in α-Al{sub 2}O{sub 3}:C,Mg

    Energy Technology Data Exchange (ETDEWEB)

    Kalita, J.M.; Chithambo, M.L., E-mail: m.chithambo@ru.ac.za

    2017-03-01

    Highlights: • Influence of dose on thermoluminescence features of α-Al{sub 2}O{sub 3}:C,Mg have been studied. • Kinetic parameters of the main peak are independent of dose (0.1–100 Gy). • Dose response of the main peak: 0.1–30 Gy, superlinear; 30–100 Gy, sublinear. • Fading of the main peak: ∼22% within 2400 s. • Reproducibility: coefficient of variation in the results of 10 re-cycles: >0.071%. - Abstract: The influence of dose (0.1–100 Gy) on the kinetic parameters and the dosimetric features of the main glow peak of α-Al{sub 2}O{sub 3}:C,Mg have been investigated. Thermoluminescence (TL) measured at 1 °C/s shows a very high intensity glow peak at 161 °C and six secondary peaks at 42, 72, 193, 279, 330, 370 °C respectively. Analysis shows that the main peak follows first order kinetics irrespective of the irradiation dose. The activation energy is found to be consistent at 1.37 eV and the frequency factor is of the order of 10{sup 14} s{sup −1} for any dose between 0.1 and 100 Gy. Further, the analysis for thermal quenching of the main peak of 0.1 Gy irradiated sample shows that the activation energy for thermal quenching is (0.94 ± 0.04) eV. Regarding the dosimetric features of α-Al{sub 2}O{sub 3}:C,Mg, the dose response of the main peak is superlinear within 0.1 to 30 Gy of beta dose and then it becomes sublinear up to 100 Gy. Fading analysis shows that the intensity of the main peak drops to ∼22% of its initial value within 2400 s after irradiation and thereafter to ∼14% within 64,800 s. Analysis of the reproducibility shows that the coefficient of variation in the results for 10 identical TL measurements show that reproducibility improves with increase in dose.

  16. Peaked signals from dark matter velocity structures in direct detection experiments

    International Nuclear Information System (INIS)

    Lang, Rafael F.; Weiner, Neal

    2010-01-01

    In direct dark matter detection experiments, conventional elastic scattering of WIMPs results in exponentially falling recoil spectra. In contrast, theories of WIMPs with excited states can lead to nuclear recoil spectra that peak at finite recoil energies E R . The peaks of such signals are typically fairly broad, with ΔE R /E peak ∼ 1. We show that in the presence of dark matter structures with low velocity dispersion, such as streams or clumps, peaks from up-scattering can become extremely narrow with FWHM of a few keV only. This differs dramatically from the conventionally expected WIMP spectrum and would, once detected, open the possibility to measure the dark matter velocity structure with high accuracy. As an intriguing example, we confront the observed cluster of 3 events near 42 keV from the CRESST commissioning run with this scenario. Inelastic dark matter particles with a wide range of parameters are capable of producing such a narrow peak. We calculate the possible signals at other experiments, and find that such particles could also give rise to the signal at DAMA, although not from the same stream. Over some range of parameters, a signal would be visible at xenon experiments. We show that such dark matter peaks are a very clear signal and can be easily disentangled from potential backgrounds, both terrestrial or due to WIMP down-scattering, by an enhanced annual modulation in both the amplitude of the signal and its spectral shape

  17. Relevance of free cash flow as a measure of generating value for owners

    Directory of Open Access Journals (Sweden)

    Bešlić Ivana

    2014-01-01

    Full Text Available In the new economy or knowledge economy the main goal of any company should be directed towards the achievement of the business in the interest of the owners, or generating the value for owners. In dynamic business environment, an effective performance measurement system is key determinant of successful implementation of corporate strategy, growth and survival of the company. Modern performance measures should provide an accurate assessment of the intrinsic value of the company, as well as the value for the owners (shareholders. The essence is maximizing the immanent or guaranteed value of the company. The immanent value is the value of a company based on internal evaluation (assessment discounted cash flows or expected cash flow in the future by the management team. Corporate managers in Serbia are facing the challenge of increasingly efficient capital markets and the competition in the future, which requires the implementation of a value oriented corporate governance, therefore this paper presents FCF (Free Cash Flow methodology of valuation. Free cash flow (FCF is the amount of cash available for owners of the company after the necessary investments in fixed assets and working capital to maintain the current scope of activities and support to planning.

  18. Asymmetry of characteristic X-ray peaks obtained by a Si(Li) detector

    Energy Technology Data Exchange (ETDEWEB)

    Visnovezky, Claudia [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Ciudad Universitaria, 5000, Cordoba (Argentina)], E-mail: cavy3@hotmail.com; Limandri, Silvina [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Ciudad Universitaria, 5000, Cordoba (Argentina)], E-mail: silvilimandri@hotmail.com; Canafoglia, Maria Elena [Centro de Investigacion y Desarrollo en Ciencias Aplicadas Dr. Jorge Ronco, Calle 47 No 257, 1900 La Plata, Argentina, Facultad de Ciencias Exactas y Facultad de Ingenieria de la UNLP, La Plata (Argentina); Bonetto, Rita [Centro de Investigacion y Desarrollo en Ciencias Aplicadas Dr. Jorge Ronco, Calle 47 No 257, 1900 La Plata, Argentina, Facultad de Ciencias Exactas y Facultad de Ingenieria de la UNLP, La Plata (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas de la Republica Argentina (Argentina)], E-mail: bonetto@quimica.unlp.edu.ar; Trincavelli, Jorge [Facultad de Matematica, Astronomia y Fisica, Universidad Nacional de Cordoba, Ciudad Universitaria, 5000, Cordoba (Argentina); Consejo Nacional de Investigaciones Cientificas y Tecnicas de la Republica Argentina (Argentina)], E-mail: jorge@quechua.fis.uncor.edu

    2007-05-15

    The asymmetry of the characteristic X-ray peaks obtained using a Si(Li) detector is mainly due to incomplete charge collection. Impurities and defects in the crystalline structure of Si can act as 'traps' for holes and electrons in their trip toward the detector electrodes. Therefore, the collected charge, and consequently the detected energy, is smaller than the expected one. The global effect is that peaks may present a 'tail' toward the low energy side. This phenomenon is more important for low energies (lower than 2.3 keV, in the case of the detector characterized). In this work, the parameters related to peak asymmetry were studied, allowing a better understanding of the trapping process mentioned above. For this purpose, spectra from mono- and multi-element samples were collected for elements with atomic number between 7 and 20. In order to describe the shape of the characteristic K peaks as a function of its energy, an asymmetric correction to a Gaussian function was proposed. Spectra were obtained by electron probe microanalysis for incidence energies between 5 and 25 keV using an energy dispersive spectrometer equipped with an ultra-thin window Si(Li) detector. It was observed that the area corresponding to the asymmetric correction exhibits an energy dependence similar to that of the mass absorption coefficient of the detector material. In addition, other two spectrometers were used to investigate the dependence of tailing on the detection system. When two spectrometers with the same kind of detector and different pulse processors were compared, peaks were more asymmetric for lower peaking time values. When two different detectors were used, differences were even more important.

  19. Resolving overlapping peaks in ARXPS data: The effect of noise and fitting method

    International Nuclear Information System (INIS)

    Muñoz-Flores, Jaime; Herrera-Gomez, Alberto

    2012-01-01

    Highlights: ► Noise is an important factor affecting the fitting of overlapping peaks in XPS data. ► The combined information in ARXPS data can be used to improve fitting reliability. ► The error on the estimation of the peak parameters depends on the peak-fitting method. ► Simultaneous fitting method is much more robust against noise than sequential fitting. ► The estimation of the error range is better done with ARXPS data than with XPS data. - Abstract: Peak-fitting of X-ray photoelectron spectroscopy (XPS) data can be very sensitive to noise when the difference on the binding energy among the peaks is smaller than the width of the peaks. This sensitivity depends on the fitting algorithm. Angle-resolved XPS (ARXPS) analysis offers the opportunity of employing the combined information contained in the data at the various angles to reduce the sensitivity to noise. The assumption of shared peak parameters (center and width) among the spectra for the different angles, and how it is introduced into the analysis, plays a basic role. Sequential fitting is the usual practice in ARXPS data peak-fitting. It consist on first estimating the center and width of the peaks from the data acquired at one of the angles, and then using those parameters as a starting approximation for fitting the data for each of the rest of the angles. An improvement of this method consists of averaging the centers and widths of the peaks obtained at the different angles, and then employing these values to assess the areas of the peaks for each angle. Another strategy for using the combined information is by assessing the peak parameters from the sum of the experimental data. The complete use of the combined information contained in the data-set is optimized by the simultaneous fitting method. It consists of the assessment of the center and width of the peaks by fitting the data at all the angles simultaneously. Computer-generated data was employed to compare the sensitivity with respect

  20. Effect of background correction on peak detection and quantification in online comprehensive two-dimensional liquid chromatography using diode array detection.

    Science.gov (United States)

    Allen, Robert C; John, Mallory G; Rutan, Sarah C; Filgueira, Marcelo R; Carr, Peter W

    2012-09-07

    A singular value decomposition-based background correction (SVD-BC) technique is proposed for the reduction of background contributions in online comprehensive two-dimensional liquid chromatography (LC×LC) data. The SVD-BC technique was compared to simply subtracting a blank chromatogram from a sample chromatogram and to a previously reported background correction technique for one dimensional chromatography, which uses an asymmetric weighted least squares (AWLS) approach. AWLS was the only background correction technique to completely remove the background artifacts from the samples as evaluated by visual inspection. However, the SVD-BC technique greatly reduced or eliminated the background artifacts as well and preserved the peak intensity better than AWLS. The loss in peak intensity by AWLS resulted in lower peak counts at the detection thresholds established using standards samples. However, the SVD-BC technique was found to introduce noise which led to detection of false peaks at the lower detection thresholds. As a result, the AWLS technique gave more precise peak counts than the SVD-BC technique, particularly at the lower detection thresholds. While the AWLS technique resulted in more consistent percent residual standard deviation values, a statistical improvement in peak quantification after background correction was not found regardless of the background correction technique used. Copyright © 2012 Elsevier B.V. All rights reserved.