Sample records for measured arterial blood

  1. Long-term facial artery catheter implantation for serial arterial blood sampling and invasive arterial blood pressure measurement in horses.

    Science.gov (United States)

    Dias, Deborah Penteado Martins; Teixeira, Luisa Gouvêa; Canola, Paulo Aléscio; Albernaz, Raquel Mincarelli; Marques, José Antônio; Neto, José Corrêa de Lacerda

    2012-06-01

    The purpose of this investigation was to evaluate surgical catheter implantation in the facial artery of horses and the long-term maintenance of such arteries using heparin and ascorbic acid as filling solution. Nine horses were implanted with a polyurethane catheter. The catheters were flushed with a heparin/ascorbic acid solution every 8h and remained patent for 25 days. Arterial blood samples were collected twice a day, and one exercise test that included serial blood samples and arterial pressure recordings was performed on a treadmill. Polyurethane catheters surgically implanted in the facial artery can be kept patent by filling with a heparin/ascorbic acid solution and provide convenient invasive arterial access in horses which is suitable for use for serial blood sampling and blood pressure recordings, even during exercise on treadmill. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. The measurement of blood speed in the pulmonary artery trunk

    Energy Technology Data Exchange (ETDEWEB)

    Saro, J P; Bula-Cruz, J [UTAD - 5000 Vila Real (Spain); Rafael, J A [Dep. Electronica e Telecomunicacoes da Univ. de Aveiro - 3800 Aveiro (Spain); Botelho, M F; Lima, J P [IBILI - Faculdade de Medicina da Univ. de Coimbra - 3000 Coimbra (Spain)

    1999-12-31

    The paper describes a non invasive methodology for the measurement of blood speed in the pulmonary artery trunk. The methodology has been tested with a moving radioactive tracer (nuclear medicine). An image processing technique is proposed, for detection and analysis of a moving object with variable shape and intensity over time (radioactive bolus). Experiments on the application of the technique in nuclear medicine are critically analysed. (authors) 9 refs., 7 figs.

  3. Ultrasonic Doppler measurement of renal artery blood flow

    Science.gov (United States)

    Freund, W. R.; Meindl, J. D.

    1975-01-01

    An extensive evaluation of the practical and theoretical limitations encountered in the use of totally implantable CW Doppler flowmeters is provided. Theoretical analyses, computer models, in-vitro and in-vivo calibration studies describe the sources and magnitudes of potential errors in the measurement of blood flow through the renal artery, as well as larger vessels in the circulatory system. The evaluation of new flowmeter/transducer systems and their use in physiological investigations is reported.

  4. Oscillometric blood pressure measurements: differences between measured and calculated mean arterial pressure.

    NARCIS (Netherlands)

    Kiers, H.D.; Hofstra, J.M.; Wetzels, J.F.M.

    2008-01-01

    Mean arterial pressure (MAP) is often used as an index of overall blood pressure. In recent years, the use of automated oscillometric blood pressure measurement devices is increasing. These devices directly measure and display MAP; however, MAP is often calculated from systolic blood pressure (SBP)

  5. Measurement of Blood Flow in an Intracranial Artery Bypass From the Internal Maxillary Artery by Intraoperative Duplex Sonography.

    Science.gov (United States)

    Yu, Zaitao; Shi, Xiang'en; Brohi, Shams Raza; Qian, Hai; Liu, Fangjun; Yang, Yang

    2017-02-01

    This study explored the hemodynamic characteristics of a subcranial-intracranial bypass from the internal maxillary artery by measuring blood flow on intraoperative duplex sonography. The hemodynamic parameters of the internal maxillary artery (n = 20), radial artery (n = 20), internal maxillary artery-middle cerebral artery bypass (n = 42), and internal maxillary artery-posterior cerebral artery bypass (n = 9) were measured by intraoperative duplex sonography. There was no significant difference in the internal diameters of the internal maxillary and radial arteries (mean ± SD, 2.51 ± 0.34 versus 2.56 ± 0.22 mm; P = .648). The mean radial artery graft length for subcranial-intracranial bypasses was 88.5 ± 12.78 mm (95% confidence interval [CI], 80.8-90.2 mm). Internal maxillary artery-middle cerebral artery bypasses required a shorter radial artery graft than internal maxillary artery-posterior cerebral artery bypasses (77.8 ± 2.47 versus 104.8 ± 4.77 mm; P = .001). The mean flow volumes were 85.3 ± 18.5 mL/min (95% CI, 76.6-93.9 mL/min) for the internal maxillary artery, 72.6 ± 26.4 mL/min (95% CI, 64.3-80.9 mL/min) for internal maxillary artery-middle cerebral artery bypasses, and 45.4 ± 6.7 mL/min (95% CI, 40.7-50.0 mL/min) for internal maxillary artery-posterior cerebral artery bypasses. All grafts were opened after the success of the salvage procedures had been established, and the early patency rates (1 month after the operation) were 95% for internal maxillary artery-middle cerebral artery bypasses and 100% the internal maxillary artery-posterior cerebral artery bypasses. Measurement of blood flow by intraoperative sonography can be helpful in decision making and predicting graft patency and success after neurosurgical bypass procedures. © 2016 by the American Institute of Ultrasound in Medicine.

  6. MR measurement of coronary arterial blood flow velocity. Evaluation of age, stenosis and drugs as factors affecting coronary blood flow

    International Nuclear Information System (INIS)

    Taoka, Yoshiaki; Harada, Masafumi; Nishitani, Hiromu; Yukinaka, Michiko; Nomura, Masahiro

    1998-01-01

    Coronary arterial blood flow velocity was measured using MRI. Two types of phase contrast methods were used for the measurements, one of which exhibited good resolving power whereas the other provided more distinct images acquired while the subject patients held their breath. Before measuring coronary arterial blood flow velocity, accuracy of the two phase contrast methods was evaluated using a phantom. The results obtained with both methods largely agreed with the values obtained using the phantom. Using both methods, the patterns of coronary arterial blood flow over one cardiac cycle were essentially identical. A peak was noted in late systole or in early diastole in the right coronary artery, whereas in the left coronary artery, a peak was noted somewhat later in diastole. In healthy volunteers, no significant difference in the maximal flow velocity in the coronary arteries was found from one age group to another. Among patients with coronary arterial stenosis, coronary arterial blood flow velocity central to the area of stenosis was lower than that observed in the healthy volunteers. Coronary arterial blood flow velocity was observed to decrease after administration of isosorbide dinitrate and increased following administration of nifedipine. (author)

  7. Classification of peripheral occlusive arterial diseases based on symptoms, signs and distal blood pressure measurements

    DEFF Research Database (Denmark)

    Tønnesen, K H; Noer, Ivan; Paaske, William

    1980-01-01

    Systolic blood pressures at toe and ankle were measured in 459 consecutive patients with occlusive arterial disease. Fifty-eight per cent had intermittent claudication with arterial disease of all degrees of severity. Seventeen per cent complained of rest pain having toe systolic pressures below 30...

  8. Resting quantitative cerebral blood flow in schizophrenia measured by pulsed arterial spin labeling perfusion MRI

    OpenAIRE

    Pinkham, Amy; Loughead, James; Ruparel, Kosha; Wu, Wen-Chau; Overton, Eve; Gur, Raquel; Gur, Ruben

    2011-01-01

    Arterial spin labeling imaging (ASL) perfusion MRI is a relatively novel technique that can allow for quantitative measurement of cerebral blood flow (CBF) by using magnetically labeled arterial blood water as an endogenous tracer. Available data on resting CBF in schizophrenia primarily comes from invasive and expensive nuclear medicine techniques that are often limited to small samples and yield mixed results. The noninvasive nature of ASL offers promise for larger-scale studies. The utilit...

  9. Measurement of blood flow in the carotid arteries using color doppler in healthy Korean adults

    International Nuclear Information System (INIS)

    Moon, Ki Ho; Jeon, Do Ig; Choi, Chang Ho; Ro, Young Jin; Kim, Hak Jin; Lee, Suck Hong; Kim, Byung Soo

    1994-01-01

    To evaluate the blood flow patterns and velocities of the carotid arteries in healthy Korean adults. We evaluated the blood flow patterns and measured the peak systolic and end-diastolic velocities of the common, internal and external carotid arteries in 48 healthy adults who did not have cardiovascular disorders and neck lesions. The velocity difference was analyzed according to different age groups. In addition, peak systolic and end-diastolic velocity ratio of the internal to common carotid artery was estimated, and our data were compared with values reported by other authors. Generally, the velocity in the younger age group tends be to higher than in older group. The peak systolic and end diastolic velocities of the internal carotid artery were 84.5 cm/sec and 30.5 cm/sec. The peak systolic and end diastolic velocity ratio of the internal to common carotid artery were 0.715 and 0.966. The internal carotid artery was less resistant in blood flow than the external carotid artery. Our data were lower than the values which were reported by Bluth et al. The blood flow velocities of the internal carotid artery in healthy adults were lower than those of previous reported foreign values, but the patterns were similar

  10. Healing of ulcers on the feet correlated with distal blood pressure measurements in occlusive arterial disease

    DEFF Research Database (Denmark)

    Holstein, P; Lassen, N A

    1980-01-01

    The frequency of healing in subchronic ulcers in 66 feet in 62 patients with arterial occlusive disease was correlated with the systolic digital blood pressure (SDBP) and the systolic ankle blood pressure (SABP), both measured with a strain gauge, and with the skin perfusion pressure on the heel...

  11. Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

    Directory of Open Access Journals (Sweden)

    Jong-Gu Choi

    2011-01-01

    Full Text Available To measure precise blood pressure (BP and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.

  12. Arterial blood pressure measurement and pulse wave analysis—their role in enhancing cardiovascular assessment

    International Nuclear Information System (INIS)

    Avolio, Alberto P; Butlin, Mark; Walsh, Andrew

    2010-01-01

    The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blood pressure obtained from the brachial cuff. Although the measurement is taken in a peripheral limb, the values are generally assumed to reflect the pressure throughout the arterial tree in large conduit arteries. Since the arterial pressure pulse becomes modified as it travels away from the heart towards the periphery, this is generally true for mean and diastolic pressure, but not for systolic pressure, and so pulse pressure. The relationship between central and peripheral pulse pressure depends on propagation characteristics of arteries. Hence, while the sphygmomanometer gives values of two single points on the pressure wave (systolic and diastolic pressure), there is additional information that can be obtained from the time-varying pulse waveform that enables an improved quantification of the systolic load on the heart and other central organs. This topical review will assess techniques of pressure measurement that relate to the use of the cuff sphygmomanometer and to the non-invasive registration and analysis of the peripheral and central arterial pressure waveform. Improved assessment of cardiovascular function in relation to treatment and management of high blood pressure will result from future developments in the indirect measurement of arterial blood pressure that involve the conventional cuff sphygmomanometer with the addition of information derived from the peripheral arterial pulse. (topical review)

  13. New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring

    OpenAIRE

    Mark van Gastel; Sander Stuijk; Gerard de Haan

    2016-01-01

    Finger-oximeters are ubiquitously used for patient monitoring in hospitals worldwide. Recently, remote measurement of arterial blood oxygenation (SpO2) with a camera has been demonstrated. Both contact and remote measurements, however, require the subject to remain static for accurate SpO2 values. This is due to the use of the common ratio-of-ratios measurement principle that measures the relative pulsatility at different wavelengths. Since the amplitudes are small, they are easily corrupted ...

  14. Measurement of regional pulmonary blood volume in patients with increased pulmonary blood flow or pulmonary arterial hypertension

    International Nuclear Information System (INIS)

    Wollmer, P.; Rozcovek, A.; Rhodes, C.G.; Allan, R.M.; Maseri, A.

    1984-01-01

    The effects of chronic increase in pulmonary blood flow and chronic pulmonary hypertension on regional pulmonary blood volume was measured in two groups of patients. One group of patients had intracardiac, left-to-right shunts without appreciable pulmonary hypertension, and the other consisted of patients with Eisenmenger's syndrome or primary pulmonary hypertension, i.e. patients with normal or reduced blood flow and severe pulmonary hypertension. A technique based on positron tomography was used to measure lung density (by transmission scanning) and regional pulmonary blood volume (after inhalation of /sup 11/CO). The distribution of pulmonary blood volume was more uniform in patients with chronic increase in pulmonary blood flow than in normal subjects. There were also indications of an absolute increase in intrapulmonary blood volume by about 15%. In patients with chronic pulmonary arterial hypertension, the distribution of pulmonary blood volume was also abnormally uniform. There was, however, no indication that overall intrapulmonary blood volume was substantially different from normal subjects. The abnormally uniform distribution of pulmonary blood volume can be explained by recruitment and/or dilatation of vascular beds. Intrapulmonary blood volume appears to be increased in patients with intracardiac, left-to-right shunts. With the development of pulmonary hypertension, intrapulmonary blood volume falls, which may be explained by reactive changes in the vasculature and/or obliteration of capillaries

  15. A pitfall in the measurement of arterial blood pressure in the ischaemic limb during elevation

    DEFF Research Database (Denmark)

    Bülow, J; Jelnes, Rolf

    1987-01-01

    In order to evaluate if elevation of the ischaemic limb above heart level is an alternative to the conventionally applied method with external counterpressure for estimation of skin perfusion pressure, femoral and popliteal artery pressures were measured directly in eight patients with occlusion...... of the superficial femoral artery. The measurements were done in the horizontal position and during elevation of the calf above heart level. During elevation relative blood flow, measured by arterio-venous oxygen saturation differences, decreased compared with the horizontal position. In contrast the popliteal...... arterial pressure decreased only by 20% of the value expected from the degree of elevation of the calf above the level of the heart. Thus, it could be calculated that calf vascular resistance increased two- to three-fold on average during elevation. Four patients were reexamined with the venous pressure...

  16. Dependence of renal blood flow on renal artery stenosis measured using CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Luedemann, Lutz [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiotherapy; Nafz, B.; Persson, P. [Charite - Universitaetsmedizin Berlin (Germany). Inst. for Vegetative Physiology; Elsner, F. [Krankenhaus am Urban, Berlin (Germany). Dept. of Anesthesiology; Grosse-Siestrup, C.; Meissler, M. [Charite - Universitaetsmedizin Berlin (Germany). Experimental Animal Unit; Gutberlet, M. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Univ. Leipzig/ Leipzig Heart Center (Germany). Dept. of Diagnostic and Interventional Radiology; Lengsfeld, P.; Voth, M. [Bayer-Schering Pharma AG, Berlin (Germany). Global Medical Affairs Diagnostic Imaging

    2011-03-15

    The present study investigates the suitability of computed tomography angiography (CTA) depicting the degree of renal artery stenosis for estimating renal blood flow (RBF) in a kidney. Materials and Methods: We investigated renal artery stenosis assessment by CTA in eight adult female hybrid pigs with an ultrasound probe implanted at the renal vein for RBF measurement. An inflatable metal-free cuff was placed around the renal artery to control the RBF. The RBF was then reduced in four steps. For each reduced RBF value and baseline RBF, CTA with a reconstructed slice thickness of 0.625 mm was performed in the arterial phase following injection of 80 ml of nonionic intravenous contrast medium. The radius of the stenotic and non-stenotic renal artery segment was measured in the reconstructed images. Results: A significant linear correlation (p < 0.0001) was found between the relative apparent stenosis (calculated as the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment) and RBF. The linear regression yielded a slope of 0.57 and a y-axis of 24.1 %. A significant linear correlation (p < 0.0001) was also found between the relative true stenosis (the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment at baseline) and the RBF. The linear regression yielded a slope of 0.67 and a y-axis of 13.8 %. Conclusion: The results show that the relative stenosis apparent on CTA differs from the true degree of renal artery stenosis. Nevertheless, the degree of renal artery stenosis determined by CTA provides a reliable estimate of the resulting RBF reduction. (orig.)

  17. Dependence of renal blood flow on renal artery stenosis measured using CT angiography

    International Nuclear Information System (INIS)

    Luedemann, Lutz; Nafz, B.; Persson, P.; Elsner, F.; Grosse-Siestrup, C.; Meissler, M.; Gutberlet, M.; Univ. Leipzig/ Leipzig Heart Center; Lengsfeld, P.; Voth, M.

    2011-01-01

    The present study investigates the suitability of computed tomography angiography (CTA) depicting the degree of renal artery stenosis for estimating renal blood flow (RBF) in a kidney. Materials and Methods: We investigated renal artery stenosis assessment by CTA in eight adult female hybrid pigs with an ultrasound probe implanted at the renal vein for RBF measurement. An inflatable metal-free cuff was placed around the renal artery to control the RBF. The RBF was then reduced in four steps. For each reduced RBF value and baseline RBF, CTA with a reconstructed slice thickness of 0.625 mm was performed in the arterial phase following injection of 80 ml of nonionic intravenous contrast medium. The radius of the stenotic and non-stenotic renal artery segment was measured in the reconstructed images. Results: A significant linear correlation (p < 0.0001) was found between the relative apparent stenosis (calculated as the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment) and RBF. The linear regression yielded a slope of 0.57 and a y-axis of 24.1 %. A significant linear correlation (p < 0.0001) was also found between the relative true stenosis (the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment at baseline) and the RBF. The linear regression yielded a slope of 0.67 and a y-axis of 13.8 %. Conclusion: The results show that the relative stenosis apparent on CTA differs from the true degree of renal artery stenosis. Nevertheless, the degree of renal artery stenosis determined by CTA provides a reliable estimate of the resulting RBF reduction. (orig.)

  18. [Invasive arterial blood pressure measurement using an aneroid pressure system in cattle].

    Science.gov (United States)

    Mosing, M; Franz, S; Iff, I; Schwendenwein, I

    2009-06-01

    The aim of this study was to compare the results of invasive arterial blood pressure measurement using an electronic pressure transducer (EPT) or an aneroid pressure system (APS) in cattle. A catheter was placed in the auricular artery of 11 adult cattle and connected to a pressure transducer via pressure line. The aneroid system was connected to the same catheter using a three-way stop-cock in the pressure line. On five occasions three consecutive measurements were performed with the APS. The mean blood pressure values of the EPT were recorded before each individual measurement. Values from each device were compared using Passing and Bablok regression of agreement and a Bland and Altman difference plot. One hundred and forty-seven paired measurements were analysed. The average bias between the two methods (EPT vs. APS) was -1.6 mmHg (95 % confidence interval [CI]: -3.0 to -0.2 mmHg). The coefficient of correlation was 1.0084. The aneroid system showed an almost perfect agreement with the EPT. This study shows that it can be used in a clinical setting as well as under field conditions to measure arterial blood pressure in cattle.

  19. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  20. Oscillometric blood pressure measurement: a simple method in screening for peripheral arterial disease

    DEFF Research Database (Denmark)

    Mehlsen, Jesper; Wiinberg, Niels; Bruce, Christopher

    2008-01-01

    Blood pressure at the ankle level is a reliable indicator of peripheral arterial disease (PAD) and the ankle brachial index (ABI) is a useful non-invasive screening tool for the early detection of atherosclerosis. In the first part of the study, systolic blood pressures obtained by oscillometry...... of PAD was sufficiently high in subjects over the age of 60 years to warrant screening. The ankle brachial index based on measurements with an oscillometric device was shown reliable in the exclusion of PAD, thereby fulfilling an important criterion for the use in screening....

  1. Arterial Transit Time-corrected Renal Blood Flow Measurement with Pulsed Continuous Arterial Spin Labeling MR Imaging.

    Science.gov (United States)

    Shimizu, Kazuhiro; Kosaka, Nobuyuki; Fujiwara, Yasuhiro; Matsuda, Tsuyoshi; Yamamoto, Tatsuya; Tsuchida, Tatsuro; Tsuchiyama, Katsuki; Oyama, Nobuyuki; Kimura, Hirohiko

    2017-01-10

    The importance of arterial transit time (ATT) correction for arterial spin labeling MRI has been well debated in neuroimaging, but it has not been well evaluated in renal imaging. The purpose of this study was to evaluate the feasibility of pulsed continuous arterial spin labeling (pcASL) MRI with multiple post-labeling delay (PLD) acquisition for measuring ATT-corrected renal blood flow (ATC-RBF). A total of 14 volunteers were categorized into younger (n = 8; mean age, 27.0 years) and older groups (n = 6; 64.8 years). Images of pcASL were obtained at three different PLDs (0.5, 1.0, and 1.5 s), and ATC-RBF and ATT were calculated using a single-compartment model. To validate ATC-RBF, a comparative study of effective renal plasma flow (ERPF) measured by 99m Tc-MAG3 scintigraphy was performed. ATC-RBF was corrected by kidney volume (ATC-cRBF) for comparison with ERPF. The younger group showed significantly higher ATC-RBF (157.68 ± 38.37 mL/min/100 g) and shorter ATT (961.33 ± 260.87 ms) than the older group (117.42 ± 24.03 mL/min/100 g and 1227.94 ± 226.51 ms, respectively; P renal ASL-MRI as debated in brain imaging.

  2. MR velocity mapping measurement of renal artery blood flow in patients with impaired kidney function

    DEFF Research Database (Denmark)

    Cortsen, M; Petersen, L.J.; Stahlberg, F

    1996-01-01

    Renal blood flow (RBF) was measured in 9 patients with chronic impaired kidney function using MR velocity mapping and compared to PAH clearance and 99mTc-DTPA scintigraphy. An image plane suitable for flow measurement perpendicular to the renal arteries was chosen from 2-dimensional MR angiography....... MR velocity mapping was performed in both renal arteries using an ECG-triggered gradient echo pulse sequence previously validated in normal volunteers. Effective renal plasma flow was calculated from the clearance rate of PAH during constant infusion and the split of renal function was evaluated...... by 99mTc-DTPA scintigraphy. A reduction of RBF was found, and there was a significant correlation between PAH clearance multiplied by 1/(1-hematocrit) and RBF determined by MR velocity mapping. Furthermore, a significant correlation between the distribution of renal function and the percent distribution...

  3. Evaluation of MR angiography and blood flow measurement in abdominal and peripheral arterial occlusive disease

    Energy Technology Data Exchange (ETDEWEB)

    Tabuchi, Kenji [Dokkyo Univ. School of Medicine, Mibu, Tochigi (Japan)

    2000-03-01

    To assess the characteristics of blood flow measurement with MR Angiography (MRA) to evaluate the status of vascular stenoses, two or three dimensional time-of-flight MRA and velocity-encoded cine MR were performed in the 230 segments of 35 patients, with abdominal and peripheral arterial occlusive diseases. In 11 of these 35 patients digital subtraction angiography was additionally underwent, and the stenotic findings was compared with MRA. There were 17 segments in which the velocity could not be measured, because the blood flow exceeded the upper limit of peak-encoded velocity (VENC) which was set at 120 cm/sec. Therefore, it is necessary to set the upper limit of VENC at higher than 120 cm/sec. There were 11 stenotic findings in DSA and 20 stenotic findings in MRA. Pulsatility Index (PI=(max velocity-min. velocity)/average velocity) were used for evaluating the blood flow waveform, and there were significant difference between the 11 stenotic findings of DSA and the others'. In summery, MRA was considered as useful examination to assess the degree of the vascular stenoses in abdominal and peripheral arterial occlusive disease. (author)

  4. Measurement of regional cerebral blood flow using one-point venous blood sampling and causality model. Evaluation by comparing with conventional continuous arterial blood sampling method

    International Nuclear Information System (INIS)

    Mimura, Hiroaki; Sone, Teruki; Takahashi, Yoshitake

    2008-01-01

    Optimal setting of the input function is essential for the measurement of regional cerebral blood flow (rCBF) based on the microsphere model using N-isopropyl-4-[ 123 I]iodoamphetamine ( 123 I-IMP), and usually the arterial 123 I-IMP concentration (integral value) in the initial 5 min is used for this purpose. We have developed a new convenient method in which 123 I-IMP concentration in arterial blood sample is estimated from that in venous blood sample. Brain perfusion single photon emission computed tomography (SPECT) with 123 I-IMP was performed in 110 cases of central nervous system disorders. The causality was analyzed between the various parameters of SPECT data and the ratio of octanol-extracted arterial radioactivity concentration during the first 5 min (Caoct) to octanol-extracted venous radioactivity concentration at 27 min after intravenous injection of 123 I-IMP (Cvoct). A high correlation was observed between the measured and estimated values of Caoct/Cvoct (r=0.856) when the following five parameters were included in the regression formula: radioactivity concentration in venous blood sampled at 27 min (Cv), Cvoct, Cvoct/Cv, and total brain radioactivity counts that were measured by a four-head gamma camera 5 min and 28 min after 123 I-IMP injection. Furthermore, the rCBF values obtained using the input parameters estimated by this method were also highly correlated with the rCBF values measured using the continuous arterial blood sampling method (r=0.912). These results suggest that this method would serve as the new, convenient and less invasive method of rCBF measurement in clinical setting. (author)

  5. Measurement of brachial artery endothelial function using a standard blood pressure cuff

    International Nuclear Information System (INIS)

    Maltz, Jonathan S; Budinger, Thomas F; Tison, Geoffrey H; Olgin, Jeffrey; Alley, Hugh F; Owens, Christopher D

    2015-01-01

    The integrity of endothelial function in major arteries (EFMA) is a powerful independent predictor of heart attack and stroke. Existing ultrasound-based non-invasive assessment methods are technically challenging and suitable only for laboratory settings. EFMA, like blood pressure (BP), is both acutely and chronically affected by factors such as lifestyle and medication. Consequently, laboratory-based measurements cannot fully gauge the effects of medical interventions on EFMA. EFMA and BP have, arguably, comparable (but complementary) value in the assessment of cardiovascular health. Widespread deployment of EFMA assessment is thus a desirable clinical goal. To this end, we propose a device based on modifying the measurement protocol of a standard electronic sphygmomanometer. The protocol involves inflating the cuff to sub-diastolic levels to enable recording of the pulse waveform before and after vasodilatory stimulus. The mechanical unloading of the arterial wall provided by the cuff amplifies the distension that occurs with each pulse, which is measured as a pressure variation in the cuff. We show that the height of the rising edge of each pulse is proportional to the change in lumen area between diastole and systole. This allows the effect of vasodilatory stimuli on the artery to be measured with high sensitivity. We compare the proposed cuff flow-mediated dilation (cFMD) method to ultrasound flow-mediated dilation (uFMD). We find significant correlation (r  =  0.55, p  =0.003, N  =  27) between cFMD- and uFMD-based metrics obtained when the release of a 5 min cuff occlusion is employed to induce endothelial stimulus via reactive hyperemia. cFMD is approximately proportional to the square of uFMD, representing a typical increase in sensitivity to vasodilation of 300–600%. This study illustrates the potential for an individual to conveniently measure his/her EFMA by using a low-cost reprogrammed home sphygmomanometer. (paper)

  6. Metabolic liver function measured in vivo by dynamic (18)F-FDGal PET/CT without arterial blood sampling.

    Science.gov (United States)

    Horsager, Jacob; Munk, Ole Lajord; Sørensen, Michael

    2015-01-01

    Metabolic liver function can be measured by dynamic PET/CT with the radio-labelled galactose-analogue 2-[(18)F]fluoro-2-deoxy-D-galactose ((18)F-FDGal) in terms of hepatic systemic clearance of (18)F-FDGal (K, ml blood/ml liver tissue/min). The method requires arterial blood sampling from a radial artery (arterial input function), and the aim of this study was to develop a method for extracting an image-derived, non-invasive input function from a volume of interest (VOI). Dynamic (18)F-FDGal PET/CT data from 16 subjects without liver disease (healthy subjects) and 16 patients with liver cirrhosis were included in the study. Five different input VOIs were tested: four in the abdominal aorta and one in the left ventricle of the heart. Arterial input function from manual blood sampling was available for all subjects. K*-values were calculated using time-activity curves (TACs) from each VOI as input and compared to the K-value calculated using arterial blood samples as input. Each input VOI was tested on PET data reconstructed with and without resolution modelling. All five image-derived input VOIs yielded K*-values that correlated significantly with K calculated using arterial blood samples. Furthermore, TACs from two different VOIs yielded K*-values that did not statistically deviate from K calculated using arterial blood samples. A semicircle drawn in the posterior part of the abdominal aorta was the only VOI that was successful for both healthy subjects and patients as well as for PET data reconstructed with and without resolution modelling. Metabolic liver function using (18)F-FDGal PET/CT can be measured without arterial blood samples by using input data from a semicircle VOI drawn in the posterior part of the abdominal aorta.

  7. Continuous estimates of dynamic cerebral autoregulation: influence of non-invasive arterial blood pressure measurements

    International Nuclear Information System (INIS)

    Panerai, R B; Smith, S M; Rathbone, W E; Samani, N J; Sammons, E L; Bentley, S; Potter, J F

    2008-01-01

    Temporal variability of parameters which describe dynamic cerebral autoregulation (CA), usually quantified by the short-term relationship between arterial blood pressure (BP) and cerebral blood flow velocity (CBFV), could result from continuous adjustments in physiological regulatory mechanisms or could be the result of artefacts in methods of measurement, such as the use of non-invasive measurements of BP in the finger. In 27 subjects (61 ± 11 years old) undergoing coronary artery angioplasty, BP was continuously recorded at rest with the Finapres device and in the ascending aorta (Millar catheter, BP AO ), together with bilateral transcranial Doppler ultrasound in the middle cerebral artery, surface ECG and transcutaneous CO 2 . Dynamic CA was expressed by the autoregulation index (ARI), ranging from 0 (absence of CA) to 9 (best CA). Time-varying, continuous estimates of ARI (ARI(t)) were obtained with an autoregressive moving-average (ARMA) model applied to a 60 s sliding data window. No significant differences were observed in the accuracy and precision of ARI(t) between estimates derived from the Finapres and BP AO . Highly significant correlations were obtained between ARI(t) estimates from the right and left middle cerebral artery (MCA) (Finapres r = 0.60 ± 0.20; BP AO r = 0.56 ± 0.22) and also between the ARI(t) estimates from the Finapres and BP AO (right MCA r = 0.70 ± 0.22; left MCA r = 0.74 ± 0.22). Surrogate data showed that ARI(t) was highly sensitive to the presence of noise in the CBFV signal, with both the bias and dispersion of estimates increasing for lower values of ARI(t). This effect could explain the sudden drops of ARI(t) to zero as reported previously. Simulated sudden changes in ARI(t) can be detected by the Finapres, but the bias and variability of estimates also increase for lower values of ARI. In summary, the Finapres does not distort time-varying estimates of dynamic CA obtained with a sliding window combined with an ARMA model

  8. Technical Note: Measurement of common carotid artery lumen dynamics using black-blood MR cine imaging.

    Science.gov (United States)

    Dai, Erpeng; Dong, Li; Zhang, Zhe; Li, Lyu; Zhang, Hui; Zhao, Xihai; Wang, Jinnan; Yuan, Chun; Guo, Hua

    2017-03-01

    To demonstrate the feasibility of measuring the common carotid artery (CCA) lumen dynamics using a black-blood cine (BB-cine) imaging method. Motion-sensitized driven-equilibrium (MSDE) prepared spoiled gradient sequence was used for the BB-cine imaging. CCAs of eleven healthy volunteers were studied using this method. Lumen dynamics, including lumen area evolution waveforms and distension values, were measured and evaluated by comparing this method with bright-blood cine (BrB-cine) imaging. Compared with the BrB-cine images, flow artifacts were effectively suppressed in the BB-cine images. BrB-cine images generally show larger lumen areas than BB-cine images. The lumen area waveforms and distension measurements from BB-cine imaging showed smaller variances among different subjects than BrB-cine imaging. The proposed BB-cine imaging technique can suppress the flow artifacts effectively and reduce the partial volume effects from the vessel wall. This might allow more accurate lumen dynamics measurements than traditional BrB-cine imaging, which may further be valuable for investigating biomechanical and functional properties of the cardiovascular system. © 2017 American Association of Physicists in Medicine.

  9. Measurement of stenotic rate and blood flow of carotid artery of the dogs with digital subtraction angiography

    International Nuclear Information System (INIS)

    Kobayashi, Keisuke; Kagawa, Masaaki; Asai, Masaaki; Yasue, Hiroshi; Kawabata, Kazuhiro; Yue, Shuzengmr

    1987-01-01

    Hemodynamic analysis of stenotic rate and local mean blood flow of the common carotid artery of the dogs with electromagnetic flowmeter and DSA was evaluated. Measurement of stenotic rate using local profile curve was very accurate and it was though to be useful in evaluation of local blood flow of the cervical carotid artery in the patients with carotid stenosis pre-and postoperatively. Although the measurement of absolute blood flow in the case of known diameter of the vessel is exactly reliable, the measured flow is not so reliable in the clinical application for the difficulty in the accurate measurement of the diameter. But hemodynamic analysis of the relative blood flow in the clinical ground can be estimated from this study. The theory and practical measurement are discussed. (author)

  10. New principle for measuring arterial blood oxygenation, enabling motion-robust remote monitoring.

    Science.gov (United States)

    van Gastel, Mark; Stuijk, Sander; de Haan, Gerard

    2016-12-07

    Finger-oximeters are ubiquitously used for patient monitoring in hospitals worldwide. Recently, remote measurement of arterial blood oxygenation (SpO 2 ) with a camera has been demonstrated. Both contact and remote measurements, however, require the subject to remain static for accurate SpO 2 values. This is due to the use of the common ratio-of-ratios measurement principle that measures the relative pulsatility at different wavelengths. Since the amplitudes are small, they are easily corrupted by motion-induced variations. We introduce a new principle that allows accurate remote measurements even during significant subject motion. We demonstrate the main advantage of the principle, i.e. that the optimal signature remains the same even when the SNR of the PPG signal drops significantly due to motion or limited measurement area. The evaluation uses recordings with breath-holding events, which induce hypoxemia in healthy moving subjects. The events lead to clinically relevant SpO 2 levels in the range 80-100%. The new principle is shown to greatly outperform current remote ratio-of-ratios based methods. The mean-absolute SpO 2 -error (MAE) is about 2 percentage-points during head movements, where the benchmark method shows a MAE of 24 percentage-points. Consequently, we claim ours to be the first method to reliably measure SpO 2 remotely during significant subject motion.

  11. A semi-automatic technique for measurement of arterial wall from black blood MRI

    International Nuclear Information System (INIS)

    Ladak, Hanif M.; Thomas, Jonathan B.; Mitchell, J. Ross; Rutt, Brian K.; Steinman, David A.

    2001-01-01

    Black blood magnetic resonance imaging (MRI) has become a popular technique for imaging the artery wall in vivo. Its noninvasiveness and high resolution make it ideal for studying the progression of early atherosclerosis in normal volunteers or asymptomatic patients with mild disease. However, the operator variability inherent in the manual measurement of vessel wall area from MR images hinders the reliable detection of relatively small changes in the artery wall over time. In this paper we present a semi-automatic method for segmenting the inner and outer boundary of the artery wall, and evaluate its operator variability using analysis of variance (ANOVA). In our approach, a discrete dynamic contour is approximately initialized by an operator, deformed to the inner boundary, dilated, and then deformed to the outer boundary. A group of four operators performed repeated measurements on 12 images from normal human subjects using both our semi-automatic technique and a manual approach. Results from the ANOVA indicate that the inter-operator standard error of measurement (SEM) of total wall area decreased from 3.254 mm2 (manual) to 1.293 mm2 (semi-automatic), and the intra-operator SEM decreased from 3.005 mm2 to 0.958 mm2. Operator reliability coefficients increased from less than 69% to more than 91% (inter-operator) and 95% (intra-operator). The minimum detectable change in wall area improved from more than 8.32 mm2 (intra-operator, manual) to less than 3.59 mm2 (inter-operator, semi-automatic), suggesting that it is better to have multiple operators measure wall area with our semi-automatic technique than to have a single operator make repeated measurements manually. Similar improvements in wall thickness and lumen radius measurements were also recorded. Since the semi-automatic technique has effectively ruled out the effect of the operator on these measurements, it may be possible to use such techniques to expand prospective studies of atherogenesis to multiple

  12. Peripheral arterial volume distensibility: significant differences with age and blood pressure measured using an applied external pressure

    International Nuclear Information System (INIS)

    Zheng, Dingchang; Murray, Alan

    2011-01-01

    A new arterial distensibility measurement technique was assessed in 100 healthy normotensive subjects. Arterial transmural pressures on the whole right arm were reduced with a 50 cm long cuff inflated to 10, 20, 30 and 40 mmHg. The electrocardiogram, and finger and ear photoplethysmograms were recorded simultaneously. Arm pulse propagation time, pulse wave velocity (PWV) and arterial volume distensibility were determined. With a 40 mmHg reduction in transmural pressure, arm pulse propagation time increased from 61 to 83 ms, PWV decreased from 12 to 8 m s −1 and arterial distensibility increased from 0.102% to 0.232% per mmHg (all P < 0.0001). At all cuff pressures, arterial distensibility was significantly related to resting mean arterial pressure (MAP), diastolic blood pressure (DBP) and age, and for systolic blood pressure at 30 and 40 mmHg (all P < 0.05). At 40 mmHg cuff pressure, arterial distensibility fell by 54% for a MAP increase from 75 to 105 mmHg, 57% for a DBP increase from 60 to 90 mmHg and 47% for an age increase from 20 to 70 years. These changes were more than double than those without cuff pressure. Our technique showed that systemic volume distensibility of the peripheral arm artery reduced with age, with a greater effect at higher external and lower transmural pressures

  13. The quantitative regional cerebral blood flow measurement with autoradiography method using 123I-IMP SPECT. Evaluation of arterialized venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ohnishi, Takashi; Yano, Takao; Nakano, Shinichi; Jinnouchi, Seishi; Nagamachi, Shigeki; Flores, L. II; Nakahara, Hiroshi; Watanabe, Katsushi.

    1996-01-01

    The purpose of this study is validation of calibrating a standard input function in autoradiography (ARG) method by one point venous blood sampling as a substitute for that by one point arterial blood sampling. Ten and 20 minutes after intravenous constant infusion of 123 I-IMP, arterialized venous blood sampling from a dorsal vein were performed on 15 patients having ischemic cerebrovascular disease. And arterial blood sampling from radial artery was performed 10 min after 123 I-IMP infusion. The mean difference rates of integrated input function between calibrated standard input function by arterial blood sampling at 10 min and that by venous blood sampling were 4.1±3% and 9.3±5.4% at 10 and 20 min after 123 I-IMP infusion, respectively. The ratio of venous blood radioactivity to arterial blood radioactivity at 10 min after 123 I-IMP infusion was 0.96±0.02. There was an excellent correlation between ARG method CBF values obtained by arterial blood sampling at 10 min and those obtained by arterialized venous blood sampling at 10 min. In conclusion, a substitution by arterialized venous blood sampling from dorsal hand vein for artery can be possible. The optimized time for arterialized venous blood sampling was 10 min after 123 I-IMP infusion. (author)

  14. Measuring systolic arterial blood pressure. Possible errors from extension tubes or disposable transducer domes.

    Science.gov (United States)

    Rothe, C F; Kim, K C

    1980-11-01

    The purpose of this study was to evaluate the magnitude of possible error in the measurement of systolic blood pressure if disposable, built-in diaphragm, transducer domes or long extension tubes between the patient and pressure transducer are used. Sinusoidal or arterial pressure patterns were generated with specially designed equipment. With a long extension tube or trapped air bubbles, the resonant frequency of the catheter system was reduced so that the arterial pulse was amplified as it acted on the transducer and, thus, gave an erroneously high systolic pressure measurement. The authors found this error to be as much as 20 mm Hg. Trapped air bubbles, not stopcocks or connections, per se, lead to poor fidelity. The utility of a continuous catheter flush system (Sorenson, Intraflow) to estimate the resonant frequency and degree of damping of a catheter-transducer system is described, as are possibly erroneous conclusions. Given a rough estimate of the resonant frequency of a catheter-transducer system and the magnitude of overshoot in response to a pulse, the authors present a table to predict the magnitude of probable error. These studies confirm the variability and unreliability of static calibration that may occur using some safety diaphragm domes and show that the system frequency response is decreased if air bubbles are trapped between the diaphragms. The authors conclude that regular procedures should be established to evaluate the accuracy of the pressure measuring systems in use, the transducer should be placed as close to the patient as possible, the air bubbles should be assiduously eliminated from the system.

  15. Ambulatory (24 h) blood pressure and arterial stiffness measurement in Marfan syndrome patients: a case control feasibility and pilot study.

    Science.gov (United States)

    Hillebrand, Matthias; Nouri, Ghazaleh; Hametner, Bernhard; Parragh, Stephanie; Köster, Jelena; Mortensen, Kai; Schwarz, Achim; von Kodolitsch, Yskert; Wassertheurer, Siegfried

    2016-05-06

    The aim of this work is the investigation of measures of ambulatory brachial and aortic blood pressure and indices of arterial stiffness and aortic wave reflection in Marfan patients. A case-control study was conducted including patients with diagnosed Marfan syndrome following Ghent2 nosology and healthy controls matched for sex, age and daytime brachial systolic blood pressure. For each subject a 24 h ambulatory blood pressure and 24 h pulse wave analysis measurement was performed. All parameters showed a circadian pattern whereby pressure dipping was more pronounced in Marfan patients. During daytime only Marfan patients with aortic root surgery showed increased pulse wave velocity. In contrast, various nighttime measurements, wave reflection determinants and circadian patterns showed a significant difference. The findings of our study provide evidence that ambulatory measurement of arterial stiffness parameters is feasible and that these determinants are significantly different in Marfan syndrome patients compared to controls in particular at nighttime. Further investigation is therefore indicated.

  16. COMPARISON OF HIGH-DEFINITION OSCILLOMETRIC AND DIRECT ARTERIAL BLOOD PRESSURE MEASUREMENT IN ANESTHETIZED CHEETAHS (ACINONYX JUBATUS).

    Science.gov (United States)

    Sant Cassia, Emma V; Boswood, Adrian; Tordiffe, Adrian S W

    2015-09-01

    Blood pressure measurement reveals important insights into the health of conscious and anesthetized individuals. This is of particular interest in cheetahs (Acinonyx jubatus), which in captivity are known to suffer from chronic diseases that may be associated with hypertension and which often require immobilization for transport or veterinary treatment. Invasive testing methods are considered the gold standard but are not practical in many settings. Consequently, it is important to evaluate the use of noninvasive methods in this species. Measurements for systolic, diastolic, and mean arterial pressure obtained using high-definition oscillometry (HDO) at the coccygeal artery were compared to simultaneous direct measurements obtained via catheterization of the femoral or dorsal pedal artery in eight anesthetized captive cheetahs during nine anesthetic events. Overall, HDO and direct measurements agreed most closely for mean arterial pressure, and the poorest agreement was observed for systolic pressure. There was a tendency for low diastolic pressures to be underestimated and for high diastolic pressures to be overestimated. Across all three parameters, HDO measurements from the tail overestimated directly measured pressures in the femoral artery and underestimated those in the dorsal pedal artery. HDO agreed most closely with directly measured dorsal pedal pressures. Mean arterial pressure showed the greatest precision (standard deviation of 10.2 mm Hg) and lowest bias (-1.2 mm Hg), with 75.9% of readings within 10 mm Hg of the direct dorsal pedal pressure. Agreement with systolic pressure was hindered by a high bias (-10.4 mm Hg), but if a correction factor of +10 mm Hg was applied to all systolic measurements, agreement was improved and 65.7% of readings were within 10 mm Hg of the direct pressure. When compared to criteria defined by the American College of Veterinary Internal Medicine for validation of blood pressure devices, results were favorable, but a

  17. Transesophageal Doppler measurement of renal arterial blood flow velocities and indices in children.

    Science.gov (United States)

    Zabala, Luis; Ullah, Sana; Pierce, Carol D'Ann; Gautam, Nischal K; Schmitz, Michael L; Sachdeva, Ritu; Craychee, Judith A; Harrison, Dale; Killebrew, Pamela; Bornemeier, Renee A; Prodhan, Parthak

    2012-06-01

    Doppler-derived renal blood flow indices have been used to assess renal pathologies. However, transesophageal ultrasonography (TEE) has not been previously used to assess these renal variables in pediatric patients. In this study, we (a) assessed whether TEE allows adequate visualization of the renal parenchyma and renal artery, and (b) evaluated the concordance of TEE Doppler-derived renal blood flow measurements/indices compared with a standard transabdominal renal ultrasound (TAU) in children. This prospective cohort study enrolled 28 healthy children between the ages of 1 and 17 years without known renal dysfunction who were undergoing atrial septal defect device closure in the cardiac catheterization laboratory. TEE was used to obtain Doppler renal artery blood velocities (peak systolic velocity, end-diastolic velocity, mean diastolic velocity, resistive index, and pulsatility index), and these values were compared with measurements obtained by TAU. Concordance correlation coefficient (CCC) was used to determine clinically significant agreement between the 2 methods. The Bland-Altman plots were used to determine whether these 2 methods agree sufficiently to be used interchangeably. Statistical significance was accepted at P ≤ 0.05. Obtaining 2-dimensional images of kidney parenchyma and Doppler-derived measurements using TEE in children is feasible. There was statistically significant agreement between the 2 methods for all measurements. The CCC between the 2 imaging techniques was 0.91 for the pulsatility index and 0.66 for the resistive index. These coefficients were sensitive to outliers. When the highest and lowest data points were removed from the analysis, the CCC between the 2 imaging techniques was 0.62 for the pulsatility index and 0.50 for the resistive index. The 95% confidence interval (CI) for pulsatility index was 0.35 to 0.98 and for resistive index was 0.21 to 0.89. The Bland-Altman plots indicate good agreement between the 2 methods; for the

  18. Closure of digital arteries in high vascular tone states as demonstrated by measurement of systolic blood pressure in the fingers

    DEFF Research Database (Denmark)

    Krähenbühl, B; Nielsen, S L; Lassen, N A

    1977-01-01

    by direct cooling or intra-arterial noradrenaline infusion caused a marked drop in FSP in the exposed fingers, but not in the non-exposed fingers of the same hand. The fact that the non-exposed fingers retained the normal (arm systolic) pressure level is taken to indicate that palmar arch blood pressure......Finger systolic blood pressure (FSP) was measured indirectly in normal subjects and patients with primary Raynaud phenomenon by applying a thin-walled plastic cuff around the finger and a strain gauge more distally to detect volume changes. Inducing a high vascular tone in one or more fingers...... also remained normal. In the high vascular tone state, a large transmural pressure difference must apparently be established before the digital arteries are forced open. The lowered opening pressure constitutes a manifestation of the closure phenomenon of the digital arteries described in patients...

  19. Effect of mechanical behaviour of the brachial artery on blood pressure measurement during both cuff inflation and cuff deflation.

    Science.gov (United States)

    Zheng, Dingchang; Pan, Fan; Murray, Alan

    2013-10-01

    The aim of this study was to investigate the effect of different mechanical behaviour of the brachial artery on blood pressure (BP) measurements during cuff inflation and deflation. BP measurements were taken from each of 40 participants, with three repeat sessions under three randomized cuff deflation/inflation conditions. Cuff pressure was linearly deflated and inflated at a standard rate of 2-3 mmHg/s and also linearly inflated at a fast rate of 5-6 mmHg/s. Manual auscultatory systolic and diastolic BPs, and pulse pressure (SBP, DBP, PP) were measured. Automated BPs were determined from digitally recorded cuff pressures by fitting a polynomial model to the oscillometric pulse amplitudes. The BPs from cuff deflation and inflation were then compared. Repeatable measurements between sessions and between the sequential order of inflation/deflation conditions (all P > 0.1) indicated stability of arterial mechanical behaviour with repeat measurements. Comparing BPs obtained by standard inflation with those from standard deflation, manual SBP was 2.6 mmHg lower (P deflation suggest different arterial mechanical behaviour between arterial opening and closing during BP measurement. We have shown that the mechanical behaviour of the brachial artery during BP measurement differs between cuff deflation and cuff inflation.

  20. A pressão arterial está sendo medida? Is the blood pressure being measured?

    Directory of Open Access Journals (Sweden)

    Débora C. Alavarce

    2000-03-01

    Full Text Available A medida da pressão arterial faz parte do exame físico e deve ser realizada em toda consulta médica. Para avaliar se a pressão arterial é medida nas consultas médicas, foram consultados 500 prontuários de pacientes de primeira consulta ambulatorial, sendo 335 (67% provenientes de clínicas médicas e cirúrgicas e 165 (33% das clínicas ginecológica e obstétrica. A pressão arterial foi anotada em 39% das consultas realizadas (135±32/85±19 mm Hg, sendo que em 11% destas anotações a pressão diastólica estava acima de 90 mm Hg. Em relação ao diagnóstico prévio de hipertensão arterial verificou-se que: a em 62% dos prontuários não havia esta informação; b 20% referiram ter hipertensão, e em 79% destes a pressão arterial foi anotada; e c 18% referiram não ter hipertensão e 46% destes tiveram registro da pressão arterial. Portanto, a maior parte dos pacientes não teve sua pressão arterial anotada.The blood pressure measure is part of the physical exam and it should be accomplished in every medical consultation. To verify the blood pressure measured in the accomplished medical consultations record of first they were consulted it consults 500 patient's ambulatorial being 335 (67% coming of medical and surgical clinics and 165 (33% of the gynecological and obstetric clinics. The blood pressure was written down in 39% of the accomplished consultations (135+32 mm Hg 85+19 mm Hg, and 11% of this annotations the pressure diastólica was above 90 mm Hg. In relation to the previous diagnosis of hypertension it was verified that: a in 62% of the records there was not this information; b 20% referred to have hypertension, and in 79% of these the arterial pressure was scored; and c 18% referred not to have hypertension and 46% of these had registration of the arterial pressure. Therefore, most of the patients didn't have its logged arterial pressure.

  1. Measurement of regional cerebral blood flow using one-point arterial blood sampling and microsphere model with 123I-IMP. Correction of one-point arterial sampling count by whole brain count ratio

    International Nuclear Information System (INIS)

    Makino, Kenichi; Masuda, Yasuhiko; Gotoh, Satoshi

    1998-01-01

    The experimental subjects were 189 patients with cerebrovascular disorders. 123 I-IMP, 222 MBq, was administered by intravenous infusion. Continuous arterial blood sampling was carried out for 5 minutes, and arterial blood was also sampled once at 5 minutes after 123 I-IMP administration. Then the whole blood count of the one-point arterial sampling was compared with the octanol-extracted count of the continuous arterial sampling. A positive correlation was found between the two values. The ratio of the continuous sampling octanol-extracted count (OC) to the one-point sampling whole blood count (TC5) was compared with the whole brain count ratio (5:29 ratio, Cn) using 1-minute planar SPECT images, centering on 5 and 29 minutes after 123 I-IMP administration. Correlation was found between the two values. The following relationship was shown from the correlation equation. OC/TC5=0.390969 x Cn-0.08924. Based on this correlation equation, we calculated the theoretical continuous arterial sampling octanol-extracted count (COC). COC=TC5 x (0.390969 x Cn-0.08924). There was good correlation between the value calculated with this equation and the actually measured value. The coefficient improved to r=0.94 from the r=0.87 obtained before using the 5:29 ratio for correction. For 23 of these 189 cases, another one-point arterial sampling was carried out at 6, 7, 8, 9 and 10 minutes after the administration of 123 I-IMP. The correlation coefficient was also improved for these other point samplings when this correction method using the 5:29 ratio was applied. It was concluded that it is possible to obtain highly accurate input functions, i.e., calculated continuous arterial sampling octanol-extracted counts, using one-point arterial sampling whole blood counts by performing correction using the 5:29 ratio. (K.H.)

  2. Cerebral blood flow measured by arterial spin labeling MRI at resting state in normal aging and Alzheimer's disease.

    Science.gov (United States)

    Zhang, Nan; Gordon, Marc L; Goldberg, Terry E

    2017-01-01

    Arterial spin labeling (ASL) magnetic resonance imaging uses arterial blood water as an endogenous tracer to measure cerebral blood flow (CBF). In this review, based on ASL studies in the resting state, we discuss state-of-the-art technical and data processing improvements in ASL, and ASL CBF changes in normal aging, mild cognitive impairment (MCI), Alzheimer's disease (AD), and other types of dementia. We propose that vascular and AD risk factors should be considered when evaluating CBF changes in aging, and that other validated biomarkers should be used as inclusion criteria or covariates when evaluating CBF changes in MCI and AD. With improvements in hardware and experimental design, ASL is proving to be an increasingly promising tool for exploring pathogenetic mechanisms, early detection, monitoring disease progression and pharmacological response, and differential diagnosis of AD. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Measurement of cerebral blood flow by single photon emission computed tomography in cases of internal carotid artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Sunada, Ichiro [Osaka City Univ. (Japan). Faculty of Medicine

    1989-06-01

    Cerebral blood flow (CBF) was measured with {sup 133}xenon inhalation and single photon emission computed tomography in 33 cases of internal carotid artery occlusion, in the resting state and 25 minutes after acetazolamide administration. The patient population consisted of 24 males and nine females with a mean age of 57 years, who presented with transient ischemic attacks or stroke. Acetazolamide inhibits carbonic anhydrase, and CBF increases as a result of dilatation of cerebral arteries due to CO{sub 2} accumulation. The mean CBF was 46 ml/100 g/min on the affected hemisphere and 56 ml/100 g/min on the unaffected hemisphere. The mean CBF value obtained by the same method in 10 normal volunteers was 55 ml/100 g/min. The average increase in CBF after acetazolamide administration was 9% on the affected side and 17% on the unaffected side. The average increase in 10 normal volunteers was 32%. The reduced cerebral arterial reactivity to acetazolamide administration was bilateral in the patient group, suggesting that the cerebral arteries were dilated so as to maintain normal CBF. Extra-intracranial (EC-IC) bypass surgery was performed in nine patients. Preoperatively, the mean CBF was 48 ml/100 g/min on the affected side and 57 ml/100 g/min on the unaffected side. With postoperative acetazolamide administration, the percent increase in CBF rose from 13% to 22% on the affected side and from 17% to 23% on the unaffected side. The bilateral change toward normal in cerebral arterial reactivity to acetazolamide indicates that the dilated cerebral arteries returned to normal after EC-IC bypass surgery. This suggests that bypass surgery is effective in patients with internal carotid artery occlusion in whom ischemia is caused only by hemodynamic factors, and that measurement of CBF via acetazolamide loading is useful in identifying appropriate candidates for bypass surgery.

  4. Comparison of Doppler and oscillometric ankle blood pressure measurement in patients with angiographically documented lower extremity arterial occlusive disease.

    Science.gov (United States)

    Nukumizu, Yoshihito; Matsushita, Masahiro; Sakurai, Tsunehisa; Kobayashi, Masayoshi; Nishikimi, Naomichi; Komori, Kimihiro

    2007-01-01

    To assess the reliability of the oscillometric method in patients with peripheral vascular disease, ankle blood pressure measurement by Doppler and oscillometry was compared. This study represents a prospective, non-blinded examination of pressure measurements in 168 patients. Twenty-two patients were included who had abdominal aortic aneurysms (AAA) and 146 had peripheral arterial occlusive disease (PAOD). Patients with PAOD were divided into 2 groups according to angiography results: a crural artery occlusion group (CAO, n = 32), and a no crural artery occlusion group (NCAO, n = 114). All subjects underwent pressure measurement by both Doppler and oscillometry. The correlation coefficient was 0.928 in AAA patients and 0.922 in PAOD patients. In CAO patients, there were significantly fewer patients whose oscillometric pressure was equivalent to the Doppler pressure (DP), as compared to NCAO patients, because the oscillometric pressure (OP) was 10% higher than DP in 44% of CAO patients. A high correlation exists between Doppler and oscillometric ankle pressure measurements irrespective of the type of vascular disease. However, the oscillometric method could not be substituted for the Doppler method completely, because there were several patients whose OP was greater than DP especially in those with crural artery occlusive disease.

  5. Utilization of arterial blood gas measurements in a large tertiary care hospital.

    Science.gov (United States)

    Melanson, Stacy E F; Szymanski, Trevor; Rogers, Selwyn O; Jarolim, Petr; Frendl, Gyorgy; Rawn, James D; Cooper, Zara; Ferrigno, Massimo

    2007-04-01

    We describe the patterns of utilization of arterial blood gas (ABG) tests in a large tertiary care hospital. To our knowledge, no hospital-wide analysis of ABG test utilization has been published. We analyzed 491 ABG tests performed during 24 two-hour intervals, representative of different staff shifts throughout the 7-day week. The clinician ordering each ABG test was asked to fill out a utilization survey. The most common reasons for requesting an ABG test were changes in ventilator settings (27.6%), respiratory events (26.4%), and routine (25.7%). Of the results, approximately 79% were expected, and a change in patient management (eg, a change in ventilator settings) occurred in 42% of cases. Many ABG tests were ordered as part of a clinical routine or to monitor parameters that can be assessed clinically or through less invasive testing. Implementation of practice guidelines may prove useful in controlling test utilization and in decreasing costs.

  6. Significance of preoperative cerebral blood flow measurements in endovascular occlusion of the internal carotid and middle cerebral arteries

    International Nuclear Information System (INIS)

    Laurent, A.; Weitzner, I.; Luft, A.; Merland, J.J.

    1988-01-01

    Cerebral blood flow (CBF) measurements during 12 endovascular balloon occlusions (ten internal carotid and two middle cerebral arteries) with good clinical and angiographic tolerance were done with repeated boluses of Xe-133 injected directly into the ipsi- and contralateral carotid systems, during the occlusion and repeated measurements with detectors on both sides (before occlusion and 5-30 minutes after occlusion). In two cases of unchanged and four of increased CBF, one reversible deficit was probably due to an embolus. In six cases of decreased CBF, two deficits occurred, characterized by a greater than 25% decrease. It seems to represent a good predictive value for intolerance to occlusion

  7. Effects of various factors on Doppler ultrasonographic measurements of radial and coccygeal arterial blood pressure in privately owned, conscious cats.

    Science.gov (United States)

    Whittemore, Jacqueline C; Nystrom, Michael R; Mawby, Dianne I

    2017-04-01

    OBJECTIVE To assess the effects of age, body condition score (BCS), and muscle condition score (MCS) on radial and coccygeal systolic arterial blood pressure (SAP) in cats. DESIGN Prospective randomized trial. ANIMALS 66 privately owned cats enrolled between May and December 2010. PROCEDURES BCS and MCS of cats were assessed by 2 investigators; SAP was measured via Doppler ultrasonic flow detector, with cats positioned in right lateral or sternal recumbency for measurements at the radial or coccygeal artery, respectively, with order of site randomized. Associations among variables were assessed through correlation coefficients, partial correlation coefficients, and ANCOVA. RESULTS Interrater reliability for BCS and MCS assessment was high (correlation coefficients, 0.95 and 0.83, respectively). No significant effect was identified for order of SAP measurement sites. Coccygeal and radial SAP were positively correlated (ρ = 0.45). The median difference in coccygeal versus radial SAP was 19 mm Hg, but differences were not consistently positive or negative. Radial SAP was positively correlated with age (ρ = 0.48) and negatively correlated with MCS (ρ = -0.30). On the basis of the correlation analysis, the association between radial SAP and MCS reflected the confounding influence of age. Coccygeal SAP was not significantly correlated with age, BCS, or MCS. CONCLUSIONS AND CLINICAL RELEVANCE Use of the coccygeal artery is recommended to reduce the confounding effects of age and sarcopenia on Doppler ultrasonographic SAP measurements in cats. Additionally, monitoring for changes in MCS is recommended for cats undergoing serial SAP measurement.

  8. A novel photoplethysmography technique to derive normalized arterial stiffness as a blood pressure independent measure in the finger vascular bed

    International Nuclear Information System (INIS)

    Tanaka, Gohichi; Sawada, Yukihiro; Kato, Yuichi; Yamakoshi, Ken-ichi; Matsumura, Kenta; Maeda, Kimihito; Horiguchi, Masami; Ohguro, Hiroshi

    2011-01-01

    Stiffening of the small artery may be the earliest sign of arteriosclerosis. However, there is no adequate method for directly assessing small arterial stiffness. In this study, the finger arterial elasticity index (FEI) was defined as the parameter n which denotes the curvilinearity of an exponential model of pressure (P)–volume (V a ) relationship (V a = a − b exp (−nP)). For the original estimation, the FEI was calculated from a compliance index from the finger photoplethysmogram whilst occluding the finger. A simple estimation of the FEI was devised by utilizing normalized pulse volume instead of the compliance index. Both estimations yielded close agreement with the exponential model in healthy young participants (study 1: n = 19). Since the FEI was dependent on finger mean blood pressure, normalized finger arterial stiffness index (FSI) was defined as standardized residual from their relationship: mean and standard deviation (SD) of the FSI were 50 ± 10 (study 2: n = 174). The mean coefficient of variation of the FSI for four measurements was 5.72% (study 3: n = 6). The mean and SD of the FSI in seven arteriosclerotic patients were 100.0 ± 13.5. In conclusion, the FEI and FSI by simple estimation are valid and useful for arteriosclerosis research

  9. Integration of Quantitative Positron Emission Tomography Absolute Myocardial Blood Flow Measurements in the Clinical Management of Coronary Artery Disease.

    Science.gov (United States)

    Gewirtz, Henry; Dilsizian, Vasken

    2016-05-31

    In the >40 years since planar myocardial imaging with(43)K-potassium was introduced into clinical research and management of patients with coronary artery disease (CAD), diagnosis and treatment have undergone profound scientific and technological changes. One such innovation is the current state-of-the-art hardware and software for positron emission tomography myocardial perfusion imaging, which has advanced it from a strictly research-oriented modality to a clinically valuable tool. This review traces the evolving role of quantitative positron emission tomography measurements of myocardial blood flow in the evaluation and management of patients with CAD. It presents methodology, currently or soon to be available, that offers a paradigm shift in CAD management. Heretofore, radionuclide myocardial perfusion imaging has been primarily qualitative or at best semiquantitative in nature, assessing regional perfusion in relative terms. Thus, unlike so many facets of modern cardiovascular practice and CAD management, which depend, for example, on absolute values of key parameters such as arterial and left ventricular pressures, serum lipoprotein, and other biomarker levels, the absolute levels of rest and maximal myocardial blood flow have yet to be incorporated into routine clinical practice even in most positron emission tomography centers where the potential to do so exists. Accordingly, this review focuses on potential value added for improving clinical CAD practice by measuring the absolute level of rest and maximal myocardial blood flow. Physiological principles and imaging fundamentals necessary to understand how positron emission tomography makes robust, quantitative measurements of myocardial blood flow possible are highlighted. © 2016 American Heart Association, Inc.

  10. Agreement of high definition oscillometry with direct arterial blood pressure measurement at different blood pressure ranges in horses under general anaesthesia.

    Science.gov (United States)

    Tünsmeyer, Julia; Hopster, Klaus; Feige, Karsten; Kästner, Sabine Br

    2015-05-01

    To determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia. Experimental study. Seven healthy warmblood horses, aged 3-11 years, weighing 470-565 kg. Measurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5 μg kg(-1) minute(-1)) over ten minutes followed by norepinephrine (0.1 mg kg(-1) IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05 mg kg(-1) IV). For analysis three pressure levels were determined: high (MAP>110 mmHg), normal (60 mmHgstandard deviation for SAP, MAP and DAP were 0.1 ± 19.4 mmHg, 0.5 ± 14.0, 4.7 ± 15.6, respectively. At high pressure levels bias and SD were 26.1 ± 37.3 (SAP), 4.2 ± 19.4 (MAP), 1.5 ± 16.8 (DAP) and at low pressures -20.0 ± 20.9 (SAP), -11.4 ± 19.6 (MAP), -4.7 ± 20.1 (DAP), with HDO measurements at a MAP <50 mmHg often failing. Good agreement with invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  11. A simple method for regional cerebral blood flow measurement by one-point arterial blood sampling and 123I-IMP microsphere model (part 2). A study of time correction of one-point blood sample count

    International Nuclear Information System (INIS)

    Masuda, Yasuhiko; Makino, Kenichi; Gotoh, Satoshi

    1999-01-01

    In our previous paper regarding determination of the regional cerebral blood flow (rCBF) using the 123 I-IMP microsphere model, we reported that the accuracy of determination of the integrated value of the input function from one-point arterial blood sampling can be increased by performing correction using the 5 min: 29 min ratio for the whole-brain count. However, failure to carry out the arterial blood collection at exactly 5 minutes after 123 I-IMP injection causes errors with this method, and there is thus a time limitation. We have now revised out method so that the one-point arterial blood sampling can be performed at any time during the interval between 5 minutes and 20 minutes after 123 I-IMP injection, with addition of a correction step for the sampling time. This revised method permits more accurate estimation of the integral of the input functions. This method was then applied to 174 experimental subjects: one-point blood samples collected at random times between 5 and 20 minutes, and the estimated values for the continuous arterial octanol extraction count (COC) were determined. The mean error rate between the COC and the actual measured continuous arterial octanol extraction count (OC) was 3.6%, and the standard deviation was 12.7%. Accordingly, in 70% of the cases, the rCBF was able to be estimated within an error rate of 13%, while estimation was possible in 95% of the cases within an error rate of 25%. This improved method is a simple technique for determination of the rCBF by 123 I-IMP microsphere model and one-point arterial blood sampling which no longer shows a time limitation and does not require any octanol extraction step. (author)

  12. Near-infrared spectroscopy measurement of the pulsatile component of cerebral blood flow and volume from arterial oscillations

    Science.gov (United States)

    Themelis, George; D'Arceuil, Helen; Diamond, Solomon G.; Thaker, Sonal; Huppert, Theodore J.; Boas, David A.

    2009-01-01

    We describe a near-infrared spectroscopy (NIRS) method to noninvasively measure relative changes in the pulsate components of cerebral blood flow (pCBF) and volume (pCBV) from the shape of heartbeat oscillations. We present a model that is used and data to show the feasibility of the method. We use a continuous-wave NIRS system to measure the arterial oscillations originating in the brains of piglets. Changes in the animals' CBF are induced by adding CO2 to the breathing gas. To study the influence of scalp on our measurements, comparative, invasive measurements are performed on one side of the head simultaneously with noninvasive measurements on the other side. We also did comparative measurements of CBF using a laser Doppler system to validate the results of our method. The results indicate that for sufficient source-detector separation, the signal contribution of the scalp is minimal and the measurements are representative of the cerebral hemodynamics. Moreover, good correlation between the results of the laser Doppler system and the NIRS system indicate that the presented method is capable of measuring relative changes in CBF. Preliminary results show the potential of this NIRS method to measure pCBF and pCBV relative changes in neonatal pigs. PMID:17343508

  13. Measurement of cerebral blood flow the blood sampling method using 99mTc-ECD. Simultaneous scintigram scanning of arterial blood samples and the brain with a gamma camera

    International Nuclear Information System (INIS)

    Hachiya, Takenori; Inugami, Atsushi; Iida, Hidehiro; Mizuta, Yoshihiko; Kawakami, Takeshi; Inoue, Minoru

    1999-01-01

    To measure regional cerebral blood flow (rCBF) by blood sampling using 99m Tc-ECD we devised a method of measuring the radioactive concentration in arterial blood sample with a gamma camera. In this method the head and a blood sample are placed within the same visual field to record the SPECT data of both specimens simultaneously. The results of an evaluation of the counting rate performance, applying the 30 hours decaying method using 99m Tc solution showed that this method is not comparable to the well-type scintillation counter and in clinical cases the active concentration in arterial blood sample remained well within the dynamic range. In addition, examination of the influence of scattered radiation from the brain by the dilution method showed that it was negligible at a distance of more than 7.5 cm between the brain and the arterial blood sample. In the present study we placed a head-shaped phantom next to the sample. The results of the examinations suggested that this method is suitable for clinical application, and because it does not require a well-type scintillation counter, it is expected to find wide application. (author)

  14. Comparison of two-dimensional MR angiography and microsphere measurement of renal blood flow for detection of renal artery stenosis

    International Nuclear Information System (INIS)

    Powers, T.A.; Lorenz, C.H.; Shetty, A.N.; Holburn, G.E.; Price, R.R.

    1990-01-01

    This paper compares depiction of the renal arteries by MR angiography to renal blood flow as determined with microspheres in a dog model of renal artery stenosis. A left renal artery stenosis was created by placement of a silk ligature. Nb-95-labeled microspheres were injected into the left ventricle and a reference blood sample was drawn. The dog was imaged in the 1.5-T MR imager with two-dimensional MR angiography sequences. The kidneys were excised, weighted, divided into sections, and counted. Two dogs were studied to date. In dog 1, left renal blood flow (RBF) was 42 mL/min/100 g and right RBF was 337 mL/min/100 g. In dog 2 left RBF was 44 mL/min/100 g and right RBF was 608 mL/min/100 g

  15. Automated segmentation of blood-flow regions in large thoracic arteries using 3D-cine PC-MRI measurements.

    Science.gov (United States)

    van Pelt, Roy; Nguyen, Huy; ter Haar Romeny, Bart; Vilanova, Anna

    2012-03-01

    Quantitative analysis of vascular blood flow, acquired by phase-contrast MRI, requires accurate segmentation of the vessel lumen. In clinical practice, 2D-cine velocity-encoded slices are inspected, and the lumen is segmented manually. However, segmentation of time-resolved volumetric blood-flow measurements is a tedious and time-consuming task requiring automation. Automated segmentation of large thoracic arteries, based solely on the 3D-cine phase-contrast MRI (PC-MRI) blood-flow data, was done. An active surface model, which is fast and topologically stable, was used. The active surface model requires an initial surface, approximating the desired segmentation. A method to generate this surface was developed based on a voxel-wise temporal maximum of blood-flow velocities. The active surface model balances forces, based on the surface structure and image features derived from the blood-flow data. The segmentation results were validated using volunteer studies, including time-resolved 3D and 2D blood-flow data. The segmented surface was intersected with a velocity-encoded PC-MRI slice, resulting in a cross-sectional contour of the lumen. These cross-sections were compared to reference contours that were manually delineated on high-resolution 2D-cine slices. The automated approach closely approximates the manual blood-flow segmentations, with error distances on the order of the voxel size. The initial surface provides a close approximation of the desired luminal geometry. This improves the convergence time of the active surface and facilitates parametrization. An active surface approach for vessel lumen segmentation was developed, suitable for quantitative analysis of 3D-cine PC-MRI blood-flow data. As opposed to prior thresholding and level-set approaches, the active surface model is topologically stable. A method to generate an initial approximate surface was developed, and various features that influence the segmentation model were evaluated. The active surface

  16. A simple method for measurement of cerebral blood flow using 123I-IMP SPECT with calibrated standard input function by one point blood sampling. Validation of calibration by one point venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Akaizawa, Takashi; Goto, Ryoui

    1994-01-01

    In a simplified method for measurement of cerebral blood flow using one 123 I-IMP SPECT scan and one point arterial blood sampling (Autoradiography method), input function is obtained by calibrating a standard input function by one point arterial blood sampling. A purpose of this study is validation of calibration by one point venous blood sampling as a substitute for one point arterial blood sampling. After intravenous infusion of 123 I-IMP, frequent arterial and venous blood sampling were simultaneously performed on 12 patients of CNS disease without any heart and lung disease and 5 normal volunteers. The radioactivity ratio of venous whole blood which obtained from cutaneous cubital vein to arterial whole blood were 0.76±0.08, 0.80±0.05, 0.81±0.06, 0.83±0.11 at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivities were always 20% lower than those of arterial blood radioactivity during 50 min. However, the ratio which obtained from cutaneous dorsal hand vein to artery were 0.93±0.02, 0.94±0.05, 0.98±0.04, 0.98±0.03, at 10, 20, 30, 50 min after 123 I-IMP infusion, respectively. The venous blood radioactivity was consistent with artery. These indicate that arterio-venous difference of radioactivity in a peripheral cutaneous vein like a dorsal hand vein is minimal due to arteriovenous shunt in palm. Therefore, a substitution by blood sampling from cutaneous dorsal hand vein for artery will be possible. Optimized time for venous blood sampling evaluated by error analysis was 20 min after 123 I-IMP infusion, which is 10 min later than that of arterial blood sampling. (author)

  17. Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room.

    Science.gov (United States)

    Karon, Brad S; Donato, Leslie J; Larsen, Chelsie M; Siebenaler, Lindsay K; Wells, Amy E; Wood-Wentz, Christina M; Shirk-Marienau, Mary E; Curry, Timothy B

    2017-09-01

    The aim of this study was to evaluate the use of a glucose meter with surgical patients under general anesthesia in the operating room. Glucose measurements were performed intraoperatively on 368 paired capillary and arterial whole blood samples using a Nova StatStrip (Nova Biomedical, USA) glucose meter and compared with 368 reference arterial whole blood glucose measurements by blood gas analyzer in 196 patients. Primary outcomes were median bias (meter minus reference), percentage of glucose meter samples meeting accuracy criteria for subcutaneous insulin dosing as defined by Parkes error grid analysis for type 1 diabetes mellitus, and accuracy criteria for intravenous insulin infusion as defined by Clinical and Laboratory Standards Institute guidelines. Time under anesthesia, patient position, diabetes status, and other variables were studied to determine whether any affected glucose meter bias. Median bias (interquartile range) was -4 mg/dl (-9 to 0 mg/dl), which did not differ from median arterial meter bias of -5 mg/dl (-9 to -1 mg/dl; P = 0.32). All of the capillary and arterial glucose meter values met acceptability criteria for subcutaneous insulin dosing, whereas only 89% (327 of 368) of capillary and 93% (344 of 368) arterial glucose meter values met accuracy criteria for intravenous insulin infusion. Time, patient position, and diabetes status were not associated with meter bias. Capillary and arterial blood glucose measured using the glucose meter are acceptable for intraoperative subcutaneous insulin dosing. Whole blood glucose on the meter did not meet accuracy guidelines established specifically for more intensive (e.g., intravenous insulin) glycemic control in the acute care environment.

  18. Reproducibility of MRI renal artery blood flow and BOLD measurements in patients with chronic kidney disease and healthy controls.

    Science.gov (United States)

    Khatir, Dinah S; Pedersen, Michael; Jespersen, Bente; Buus, Niels H

    2014-11-01

    Determine the reproducibility of renal artery blood flow (RABF) and blood-oxygenation level dependent (R2 *) in patients with chronic kidney disease (CKD) and healthy controls. RABF and R2 * were measured in 11 CKD patients and 9 controls twice with 1- to 2-week interval. R2 * in the cortex and medulla were determined after breathing atmospheric air and 100% oxygen. Reproducibility was evaluated by coefficients of variation (CV), limits of agreements and intra-class coefficient calculated by variance components by maximum likelihood modeling. Single-kidney RABF (mL/min) for patients was: 170 ± 130 and 186 ± 137, and for controls: 365 ± 119 and 361 ± 107 (P Renal cortical R2 * was: 13.6 ± 0.9 and 13.5 ± 1.2 in patients (CV = 8.0%), and 13.8 ± 1.6 and 14.0 ± 1.5 in controls (CV = 5.6%), while medullary R2 *(s(-1) ) was: 26.9 ± 2.0 and 27.0 ± 4.0 (CV = 8.0%) in patients, and 26.0 ± 2.4 and 26.1 ± 2.1 (CV = 3.6%) in controls, for first and second scans, respectively. In both groups R2 * in medulla decreased after breathing 100% oxygen. The reproducibility was high for both RABF and R2 * in patients and controls, particularly in the cortex. Inhalation of 100% oxygen reduced medullary R2 *. © 2013 Wiley Periodicals, Inc.

  19. Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure

    NARCIS (Netherlands)

    Imholz, B. P.; Settels, J. J.; van der Meiracker, A. H.; Wesseling, K. H.; Wieling, W.

    1990-01-01

    The aim of the study was to evaluate whether invasive blood pressure responses to orthostatic stress can be replaced by non-invasive continuous finger blood pressure responses. DESIGN - Intrabrachial and Finapres blood pressures were simultaneously measured during passive head up tilt and during

  20. The effect of blood inflow and B(1)-field inhomogeneity on measurement of the arterial input function in axial 3D spoiled gradient echo dynamic contrast-enhanced MRI.

    Science.gov (United States)

    Roberts, Caleb; Little, Ross; Watson, Yvonne; Zhao, Sha; Buckley, David L; Parker, Geoff J M

    2011-01-01

    A major potential confound in axial 3D dynamic contrast-enhanced magnetic resonance imaging studies is the blood inflow effect; therefore, the choice of slice location for arterial input function measurement within the imaging volume must be considered carefully. The objective of this study was to use computer simulations, flow phantom, and in vivo studies to describe and understand the effect of blood inflow on the measurement of the arterial input function. All experiments were done at 1.5 T using a typical 3D dynamic contrast-enhanced magnetic resonance imaging sequence, and arterial input functions were extracted for each slice in the imaging volume. We simulated a set of arterial input functions based on the same imaging parameters and accounted for blood inflow and radiofrequency field inhomogeneities. Measured arterial input functions along the vessel length from both in vivo and the flow phantom agreed with simulated arterial input functions and show large overestimations in the arterial input function in the first 30 mm of the vessel, whereas arterial input functions measured more centrally achieve accurate contrast agent concentrations. Use of inflow-affected arterial input functions in tracer kinetic modeling shows potential errors of up to 80% in tissue microvascular parameters. These errors emphasize the importance of careful placement of the arterial input function definition location to avoid the effects of blood inflow. © 2010 Wiley-Liss, Inc.

  1. Regional cerebral blood flow measurements by a noninvasive microsphere method using 123I-IMP. Comparison with the modified fractional uptake method and the continuous arterial blood sampling method

    International Nuclear Information System (INIS)

    Nakano, Seigo; Matsuda, Hiroshi; Tanizaki, Hiroshi; Ogawa, Masafumi; Miyazaki, Yoshiharu; Yonekura, Yoshiharu

    1998-01-01

    A noninvasive microsphere method using N-isopropyl-p-( 123 I)iodoamphetamine ( 123 I-IMP), developed by Yonekura et al., was performed in 10 patients with neurological diseases to quantify regional cerebral blood flow (rCBF). Regional CBF values by this method were compared with rCBF values simultaneously estimated from both the modified fractional uptake (FU) method using cardiac output developed by Miyazaki et al. and the conventional method with continuous arterial blood sampling. In comparison, we designated the factor which converted raw SPECT voxel counts to rCBF values as a CBF factor. A highly significant correlation (r=0.962, p<0.001) was obtained in the CBF factors between the present method and the continuous arterial blood sampling method. The CBF factors by the present method were only 2.7% higher on the average than those by the continuous arterial blood sampling method. There were significant correlation (r=0.811 and r=O.798, p<0.001) in the CBF factor between modified FU method (threshold for estimating total brain SPECT counts; 10% and 30% respectively) and the continuous arterial blood sampling method. However, the CBF factors of the modified FU method showed 31.4% and 62.3% higher on the average (threshold; 10% and 30% respectively) than those by the continuous arterial blood sampling method. In conclusion, this newly developed method for rCBF measurements was considered to be useful for routine clinical studies without any blood sampling. (author)

  2. Measuring arterial oxygenation in a high altitude field environment: comparing portable pulse oximetry with blood gas analysis.

    Science.gov (United States)

    Ross, Elliot M; Matteucci, Michael J; Shepherd, Matthew; Barker, Matthew; Orr, Lance

    2013-06-01

    High altitude environments present unique medical treatment challenges. Medical providers often use small portable pulse oximetry devices to help guide their clinical decision making. A significant body of high altitude research is based on the use of these devices to monitor hypoxia, yet there is a paucity of evidence that these devices are accurate in these environments. We studied whether these devices perform accurately and reliably under true mountain conditions. Healthy unacclimatized active-duty military volunteers participating in mountain warfare training at 2100 m (6900 feet) above sea level were evaluated with several different pulse oximetry devices while in a cold weather, high altitude field environment and then had arterial blood gases (ABG) drawn using an i-STAT for comparison. The pulse oximeter readings were compared with the gold standard ABG readings. A total of 49 individuals completed the study. There was no statistically significant difference between any of the devices and the gold standard of ABG. The best performing device was the PalmSAT (PS) 8000SM finger probe with a mean difference of 2.17% and SD of 2.56 (95% CI, 1.42% to 2.92%). In decreasing order of performance were the PS 8000AA finger probe (mean ± SD, 2.54% ± 2.68%; 95% CI, 1.76% to 3.32%), the PS 8000Q ear probe (2.47% ± 4.36%; 95% CI, 1.21% to 3.75%), the Nonin Onyx 9500 (3.29% ± 3.12%; 95% CI, 2.39% to 4.20%), and finally the PS 8000R forehead reflectance sensor (5.15% ± 2.97%; 95% CI, 4.28% to 6.01%). Based on the results of this study, results of the newer portable pulse oximeters appear to be closely correlated to that of the ABG measurements when tested in true mountain conditions. Copyright © 2013 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  3. 21 CFR 868.1100 - Arterial blood sampling kit.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...

  4. Closure of digital arteries in high vascular tone states as demonstrated by measurement of systolic blood pressure in the fingers

    DEFF Research Database (Denmark)

    Krähenbühl, B; Nielsen, S L; Lassen, N A

    1977-01-01

    Finger systolic blood pressure (FSP) was measured indirectly in normal subjects and patients with primary Raynaud phenomenon by applying a thin-walled plastic cuff around the finger and a strain gauge more distally to detect volume changes. Inducing a high vascular tone in one or more fingers by ...

  5. Why use Finapres or Portapres rather than intra-arterial or intermittent non-invasive techniques of blood pressure measurement?

    NARCIS (Netherlands)

    Langewouters, G. J.; Settels, J. J.; Roelandt, R.; Wesseling, K. H.

    1998-01-01

    In the clinic, blood pressure is measured almost exclusively using non-invasive intermittent techniques, of which the auscultatory (Riva-Rocci/Korotkoff, RRK) and the computerized oscillometric method are most often used. However, both methods only provide a momentary value. In addition, the

  6. [Measurements of blood velocities using duplex sonography in carotid artery stents: analysis of reliability in an in-vitro model and computational fluid dynamics (CFD)].

    Science.gov (United States)

    Schönwald, U G; Jorczyk, U; Kipfmüller, B

    2011-01-01

    Stents are commonly used for the treatment of occlusive artery diseases in carotid arteries. Today, there is a controversial discussion as to whether duplex sonography (DS) displays blood velocities (BV) that are too high in stented areas. The goal of this study was to evaluate the effect of stenting on DS with respect to BV in artificial carotid arteries. The results of computational fluid dynamics (CFD) were also used for the comparison. To analyze BV using DS, a phantom with a constant flow (70 cm/s) was created. Three different types of stents for carotid arteries were selected. The phantom fluid consisted of 67 % water and 33 % glycerol. All BV measurements were carried out on the last third of the stents. Furthermore, all test runs were simulated using CFD. All measurements were statistically analyzed. DS-derived BV values increased significantly after the placement of the Palmaz Genesis stent (77.6 ± 4.92 cm/sec, p = 0.03). A higher increase in BV values was registered when using the Precise RX stent (80.1 ± 2.01 cm/sec, p CFD simulations showed similar results. Stents have a significant impact on BV, but no effect on DS. The main factor of the blood flow acceleration is the material thickness of the stents. Therefore, different stents need different velocity criteria. Furthermore, the results of computational fluid dynamics prove that CFD can be used to simulate BV in stented silicone tubes. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Middle cerebral artery blood velocity during running

    NARCIS (Netherlands)

    Lyngeraa, T. S.; Pedersen, L. M.; Mantoni, T.; Belhage, B.; Rasmussen, L. S.; van Lieshout, J. J.; Pott, F. C.

    2013-01-01

    Running induces characteristic fluctuations in blood pressure (BP) of unknown consequence for organ blood flow. We hypothesized that running-induced BP oscillations are transferred to the cerebral vasculature. In 15 healthy volunteers, transcranial Doppler-determined middle cerebral artery (MCA)

  8. Measurement of the blood flow rate and velocity in coronary artery stenosis using intracoronary frequency domain optical coherence tomography: Validation against fractional flow reserve.

    Science.gov (United States)

    Zafar, Haroon; Sharif, Faisal; Leahy, Martin J

    2014-12-01

    The main objective of this study was to assess the blood flow rate and velocity in coronary artery stenosis using intracoronary frequency domain optical coherence tomography (FD-OCT). A correlation between fractional flow reserve (FFR) and FD-OCT derived blood flow velocity is also included in this study. A total of 20 coronary stenoses in 15 patients were assessed consecutively by quantitative coronary angiography (QCA), FFR and FD-OCT. A percutaneous coronary intervention (PCI) optimization system was used in this study which combines wireless FFR measurement and FD-OCT imaging in one platform. Stenoses were labelled severe if FFR ≤ 0.8. Blood flow rate and velocity in each stenosis segment were derived from the volumetric analysis of the FD-OCT pull back images. The FFR value was ≤ 0.80 in 5 stenoses (25%). The mean blood flow rate in severe coronary stenosis ( n  = 5) was 2.54 ± 0.55 ml/s as compared to 4.81 ± 1.95 ml/s in stenosis with FFR > 0.8 ( n  = 15). A good and significant correlation between FFR and FD-OCT blood flow velocity in coronary artery stenosis ( r  = 0.74, p  < 0.001) was found. The assessment of stenosis severity using FD-OCT derived blood flow rate and velocity has the ability to overcome many limitations of QCA and intravascular ultrasound (IVUS).

  9. Regional blood flow analysis and its relationship with arterial branch lengths and lumen volume in the coronary arterial tree

    International Nuclear Information System (INIS)

    Molloi, Sabee; Wong, Jerry T

    2007-01-01

    The limitations of visually assessing coronary artery disease are well known. These limitations are particularly important in intermediate coronary lesions (30-70% diameter stenosis) where it is difficult to determine whether a particular lesion is the cause of ischaemia. Therefore, a functional measure of stenosis severity is needed. The purpose of this study is to determine whether the expected maximum coronary blood flow in an arterial tree is predictable from its sum of arterial branch lengths or lumen volume. Using a computer model of a porcine coronary artery tree, an analysis of blood flow distribution was conducted through a network of millions of vessels that included the entire coronary artery tree down to the first capillary branch. The flow simulation results show that there is a linear relationship between coronary blood flow and the sum of its arterial branch lengths. This relationship holds over the entire arterial tree. The flow simulation results also indicate that there is a 3/4 er relation between coronary blood flow (Q) and the sum of its arterial lumen volume (V). Moreover, there is a linear relationship between normalized Q and normalized V raised to a power of 3/4 over the entire arterial tree. These results indicate that measured arterial branch lengths or lumen volumes can be used to predict the expected maximum blood flow in an arterial tree. This theoretical maximum blood flow, in conjunction with an angiographically measured blood flow, can potentially be used to calculate fractional flow reserve based entirely on angiographic data

  10. Color Doppler measurement of blood flow in the inferior thyroid artery in patients with autoimmune thyroid diseases

    International Nuclear Information System (INIS)

    Caruso, Giuseppe; Attard, Marco; Caronia, Aurelio; Lagalla, Roberto

    2000-01-01

    Purpose: The aim of the study is to find out whether the measurement of peak systolic velocity in the inferior thyroid artery (ITA) is a valuable parameter to differentiate autoimmune thyroid diseases (hyper-, normo- or hypofunctional) and to evaluate the efficacy of medical treatment. Material and methods: The ITA of 31 patients (eight with Graves' disease, 23 with subclinical hypothyroidism) was examined with color Doppler and pulsed Doppler. The final diagnosis was obtained by citology and by hormonal and antibodies assays. The patients were monitorized by ultrasound for a period of 8 months. Results: In all the patients with Graves' disease the peak systolic velocity was always over 150 cm/s, while in other autoimmune thyroiditis the peak systolic velocity was within the normal range, and never exceeding 65 cm/s. In the first group, the measurement taken in the ITA showed also the efficacy of the pharmacological treatment earlier and more reliably than the color Doppler pattern obtained in the parenchyma. Conclusions: The color Doppler measurement of the ITA seems to be a promising technique with low-cost and easy approach. In our experience, the color Doppler of the ITA could have a clinical role in the differential diagnosis of diffuse thyroid diseases and in the follow-up of the Graves' disease during medical treatment

  11. Color Doppler measurement of blood flow in the inferior thyroid artery in patients with autoimmune thyroid diseases

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Giuseppe; Attard, Marco; Caronia, Aurelio; Lagalla, Roberto

    2000-10-01

    Purpose: The aim of the study is to find out whether the measurement of peak systolic velocity in the inferior thyroid artery (ITA) is a valuable parameter to differentiate autoimmune thyroid diseases (hyper-, normo- or hypofunctional) and to evaluate the efficacy of medical treatment. Material and methods: The ITA of 31 patients (eight with Graves' disease, 23 with subclinical hypothyroidism) was examined with color Doppler and pulsed Doppler. The final diagnosis was obtained by citology and by hormonal and antibodies assays. The patients were monitorized by ultrasound for a period of 8 months. Results: In all the patients with Graves' disease the peak systolic velocity was always over 150 cm/s, while in other autoimmune thyroiditis the peak systolic velocity was within the normal range, and never exceeding 65 cm/s. In the first group, the measurement taken in the ITA showed also the efficacy of the pharmacological treatment earlier and more reliably than the color Doppler pattern obtained in the parenchyma. Conclusions: The color Doppler measurement of the ITA seems to be a promising technique with low-cost and easy approach. In our experience, the color Doppler of the ITA could have a clinical role in the differential diagnosis of diffuse thyroid diseases and in the follow-up of the Graves' disease during medical treatment.

  12. Middle cerebral artery blood velocity during running

    DEFF Research Database (Denmark)

    Lyngeraa, Tobias; Pedersen, Lars Møller; Mantoni, T

    2013-01-01

    for eight subjects, respectively, were excluded from analysis because of insufficient signal quality. Running increased mean arterial pressure and mean MCA velocity and induced rhythmic oscillations in BP and in MCA velocity corresponding to the difference between step rate and heart rate (HR) frequencies....... During running, rhythmic oscillations in arterial BP induced by interference between HR and step frequency impact on cerebral blood velocity. For the exercise as a whole, average MCA velocity becomes elevated. These results suggest that running not only induces an increase in regional cerebral blood flow...

  13. [Prognostic Doppler ultrasound examination of fetal arteries blood flow].

    Science.gov (United States)

    Sieroszewski, Piotr; Sabatowska, Małgorzata; Karowicz-Bilińska, Agata; Suzin, Jacek

    2002-08-01

    Early detection of fetal risk is one of the main issues in today obstetrics. Ultrasound diagnostics plays a significant role, as the introduction of Doppler imaging method in the evaluation of blood flow has enabled non-invasive assessment of uteroplacental circulation. Therefore, we have analysed foetal three arteries: umbilical artery, middle cerebral artery and renal artery after determining the normal range for the analysed parameters. 1. Comparison of the obtained blood flow indices (S/D, RI, PI) in the umbilical artery, middle cerebral artery and renal artery of foetuses from normal and complicated full-term pregnancies. 2. Determination of indices: umbilical-cerebral and renal-cerebral in normal and pathological pregnancy. 3. Evaluation of feasibility of the analysed flow parameters for the detection of intrauterine foetal hypoxia. We have examined 151 women, who were divided into control group--101 pregnant women with normal pregnancy and study group--50 pregnant women with complicated pregnancy. All pregnant women underwent ultrasound examination using the Hitachi EUB 515 C (Japan) scanner with 3.5 MHz convex probe, connected to the colour pulsed Doppler. The study consisted of the biometric measurements and evaluation of the spectrum of blood flow in the umbilical artery, middle cerebral artery and renal artery. We have determined following indices: a) systolic-diastolic ratio S/D, resistance index RI, pulsatility index PI, b) umbilical-cerebral ratio P/M. (PI ua/PI mca), renal--cerebral ratio N/M (PI ra/PI mca). Statistically significant difference was found between the study and control groups for all the flow indices assessed (S/D, RI, PI) for the middle cerebral artery, for the indices P/M and N/M. (p < 0.001) and pulsatility index in the renal artery (p < 0.01). Similar, although slightly smaller difference (p < 0.05) was seen for the values of flow parameters in the umbilical artery. 1) Evaluation of blood flow in the middle cerebral artery, and in

  14. Novel system using microliter order sample volume for measuring arterial radioactivity concentrations in whole blood and plasma for mouse PET dynamic study.

    Science.gov (United States)

    Kimura, Yuichi; Seki, Chie; Hashizume, Nobuya; Yamada, Takashi; Wakizaka, Hidekatsu; Nishimoto, Takahiro; Hatano, Kentaro; Kitamura, Keishi; Toyama, Hiroshi; Kanno, Iwao

    2013-11-21

    This study aimed to develop a new system, named CD-Well, for mouse PET dynamic study. CD-Well allows the determination of time-activity curves (TACs) for arterial whole blood and plasma using 2-3 µL of blood per sample; the minute sample size is ideal for studies in small animals. The system has the following merits: (1) measures volume and radioactivity of whole blood and plasma separately; (2) allows measurements at 10 s intervals to capture initial rapid changes in the TAC; and (3) is compact and easy to handle, minimizes blood loss from sampling, and delay and dispersion of the TAC. CD-Well has 36 U-shaped channels. A drop of blood is sampled into the opening of the channel and stored there. After serial sampling is completed, CD-Well is centrifuged and scanned using a flatbed scanner to define the regions of plasma and blood cells. The length measured is converted to volume because the channels have a precise and uniform cross section. Then, CD-Well is exposed to an imaging plate to measure radioactivity. Finally, radioactivity concentrations are computed. We evaluated the performance of CD-Well in in vitro measurement and in vivo (18)F-fluorodeoxyglucose and [(11)C]2-carbomethoxy-3β-(4-fluorophenyl) tropane studies. In in vitro evaluation, per cent differences (mean±SE) from manual measurement were 4.4±3.6% for whole blood and 4.0±3.5% for plasma across the typical range of radioactivity measured in mouse dynamic study. In in vivo studies, reasonable TACs were obtained. The peaks were captured well, and the time courses coincided well with the TAC derived from PET imaging of the heart chamber. The total blood loss was less than 200 µL, which had no physiological effect on the mice. CD-Well demonstrates satisfactory performance, and is useful for mouse PET dynamic study.

  15. Techniques for Non-Invasive Monitoring of Arterial Blood Pressure

    Directory of Open Access Journals (Sweden)

    Agnes S. Meidert

    2018-01-01

    Full Text Available Since both, hypotension and hypertension, can potentially impair the function of vital organs such as heart, brain, or kidneys, monitoring of arterial blood pressure (BP is a mainstay of hemodynamic monitoring in acutely or critically ill patients. Arterial BP can either be obtained invasively via an arterial catheter or non-invasively. Non-invasive BP measurement provides either intermittent or continuous readings. Most commonly, an occluding upper arm cuff is used for intermittent non-invasive monitoring. BP values are then obtained either manually (by auscultation of Korotkoff sounds or palpation or automatically (e.g., by oscillometry. For continuous non-invasive BP monitoring, the volume clamp method or arterial applanation tonometry can be used. Both techniques enable the arterial waveform and BP values to be obtained continuously. This article describes the different techniques for non-invasive BP measurement, their advantages and limitations, and their clinical applicability.

  16. Racial Differences in Abnormal Ambulatory Blood Pressure Monitoring Measures: Results From the Coronary Artery Risk Development in Young Adults (CARDIA) Study

    Science.gov (United States)

    Lewis, Cora E.; Diaz, Keith M.; Carson, April P.; Kim, Yongin; Calhoun, David; Yano, Yuichiro; Viera, Anthony J.; Shimbo, Daichi

    2015-01-01

    BACKGROUND Several ambulatory blood pressure monitoring (ABPM) measures have been associated with increased cardiovascular disease risk independent of clinic blood pressure (BP). African Americans have higher clinic BP compared with Whites but few data are available on racial differences in ABPM measures. METHODS We compared ABPM measures between African American (n = 178) and White (n = 103) participants at the Year 5 Coronary Artery Risk Development in Young Adults study visit. BP was measured during a study visit and the second and third measurements were averaged. ABPM was conducted over the following 24 hours. RESULTS Mean ± SD age of participants was 29.8±3.8 years and 30.8±3.5 years for African Americans and Whites, respectively. Mean daytime systolic BP (SBP) was 3.90 (SD 1.18) mm Hg higher among African Americans compared with Whites (P ABPM was higher among African Americans compared with Whites. CONCLUSIONS These data suggest racial differences in several ABPM measures exist. PMID:25376639

  17. Serial blood pressure measurements

    Directory of Open Access Journals (Sweden)

    N.R. Koehler

    2002-05-01

    Full Text Available The objective of the present investigation was to study the effects of a 60-s interval of venous congestion between two noninvasive measurements of arterial blood pressure (ABP on the fluctuation of ABP, assessed by the standard deviation of the differences between two readings. ABP was measured in 345 successive patients, at rest, four times each. For 269 participants, one pair of readings was obtained with a 60-s interval and the other pair without an interval. For 76 patients, the first pair was read at the same interval, and the second pair had venous congestion interposed and there was no waiting interval. There was no increased ABP oscillation, either when there was no interval between ABP readings, or when venous congestion was interposed compared to pairs of ABP measurements performed with a 60-s interval. There was no increase in ABP oscillations when successive ABP readings were taken without an interval or even with venous congestion interposed. Contrary to the present belief, there seems to be no loss of reliability when blood pressure recordings are taken immediately one after another, in the clinical setting.

  18. Bedside arterial blood gas monitoring system using fluorescent optical sensors

    Science.gov (United States)

    Bartnik, Daniel J.; Rymut, Russell A.

    1995-05-01

    We describe a bedside arterial blood gas (ABG) monitoring system which uses fluorescent optical sensors in the measurement of blood pH, PCO2 and PO2. The Point-of-Care Arterial Blood Gas Monitoring System consists of the SensiCathTM optical sensor unit manufactured by Optical Sensors Incorporated and the TramTM Critical Care Monitoring System with ABG Module manufactured by Marquette Electronics Incorporated. Current blood gas measurement techniques require a blood sample to be removed from the patient and transported to an electrochemical analyzer for analysis. The ABG system does not require removal of blood from the patient or transport of the sample. The sensor is added to the patient's existing arterial line. ABG measurements are made by drawing a small blood sample from the arterial line in sufficient quantity to ensure an undiluted sample at the sensor. Measurements of pH, PCO2 and PO2 are made within 60 seconds. The blood is then returned to the patient, the line flushed and results appear on the bedside monitor. The ABG system offers several advantages over traditional electrochemical analyzers. Since the arterial line remains closed during the blood sampling procedure the patient's risk of infection is reduced and the caregiver's exposure to blood is eliminated. The single-use, disposable sensor can be measure 100 blood samples over 72 hours after a single two-point calibration. Quality Assurance checks are also available and provide the caregiver the ability to assess system performance even after the sensor is patient attached. The ABG module integrates with an existing bedside monitoring system. This allows ABG results to appear on the same display as ECG, respiration, blood pressure, cardiac output, SpO2, and other clinical information. The small module takes up little space in the crowded intensive care unit. Performance studies compare the ABG system with an electrochemical blood gas analyzer. Study results demonstrated accurate and precise blood

  19. Agreement between arterial partial pressure of carbon dioxide and saturation of hemoglobin with oxygen values obtained by direct arterial blood measurements versus noninvasive methods in conscious healthy and ill foals.

    Science.gov (United States)

    Wong, David M; Alcott, Cody J; Wang, Chong; Bornkamp, Jennifer L; Young, Jessica L; Sponseller, Brett A

    2011-11-15

    To determine agreement between indirect measurements of end-tidal partial pressure of carbon dioxide (PetCO(2)) and saturation of hemoglobin with oxygen as measured by pulse oximetry (SpO(2)) with direct measurements of PaCO(2) and calculated saturation of hemoglobin with oxygen in arterial blood (SaO(2)) in conscious healthy and ill foals. Validation study. 10 healthy and 21 ill neonatal foals. Arterial blood gas analysis was performed on healthy and ill foals examined at a veterinary teaching hospital to determine direct measurements of PaCO(2) and PaO(2) along with SaO(2). Concurrently, PetCO(2) was measured with a capnograph inserted into a naris, and SpO(2) was measured with a reflectance probe placed at the base of the tail. Paired values were compared by use of Pearson correlation coefficients, and level of agreement was assessed with the Bland-Altman method. Mean ± SD difference between PaCO(2) and PetCO(2) was 0.1 ± 5.0 mm Hg. There was significant strong correlation (r = 0.779) and good agreement between PaCO(2) and PetCO(2). Mean ± SD difference between SaO(2) and SpO(2) was 2.5 ± 3.5%. There was significant moderate correlation (r = 0.499) and acceptable agreement between SaO(2) and SpO(2). Both PetCO(2) obtained by use of nasal capnography and SpO(2) obtained with a reflectance probe are clinically applicable and accurate indirect methods of estimating and monitoring PaCO(2) and SaO(2) in neonatal foals. Indirect methods should not replace periodic direct measurement of corresponding parameters.

  20. Noninvasive 24-hour ambulatory arterial blood pressure monitoring in cirrhosis

    DEFF Research Database (Denmark)

    Møller, Søren; Wiinberg, N; Henriksen, Jens Henrik

    1995-01-01

    Cirrhotic patients have disturbed systemic hemodynamics with reduced arterial blood pressure, but this has not been investigated during daily activity and sleep. Systolic (SBP), diastolic (DBP), and mean arterial blood pressure (MAP), and heart rate (HR) were measured by an automatic ambulant...... device for monitoring blood pressure in 35 patients with cirrhosis and 35 healthy matched controls. During the daytime, SBP, DBP, and MAP were significantly lower in the patients than in the controls (median 118 vs. 127; 70 vs. 78; 86 vs. 94 mm Hg, P blood pressures...... were almost similar in the two groups (108 vs. 110; 65 vs. 67; 78 vs. 82 mm Hg, NS). Conversely, HR was significantly higher in the patients both in the daytime (86 vs. 72/min, P blood pressure and HR from daytime...

  1. Effect of kefir and low-dose aspirin on arterial blood pressure measurements and renal apoptosis in unhypertensive rats with 4 weeks salt diet.

    Science.gov (United States)

    Kanbak, Güngör; Uzuner, Kubilay; Kuşat Ol, Kevser; Oğlakçı, Ayşegül; Kartkaya, Kazım; Şentürk, Hakan

    2014-01-01

    Abstract We aim to study the effect of low-dose aspirin and kefir on arterial blood pressure measurements and renal apoptosis in unhypertensive rats with 4 weeks salt diet. Forty adult male Sprague-Dawley rats were divided into five groups: control, high-salt (HS) (8.0% NaCl), HS+aspirin (10 mg/kg), HS+kefir (10.0%w/v), HS+aspirin +kefir. We measured sistolic blood pressure (SBP), mean arterial pressure (MAP), diastolic pressure, pulse pressure in the rats. Cathepsin B, L, DNA fragmentation and caspase-3 activities were determined from rat kidney tissues and rats clearance of creatinine calculated. Although HS diet increased significantly SBP, MAP, diastolic pressure, pulse pressure parameters compared the control values. They were not as high as accepted hypertension levels. When compared to HS groups, kefir groups significantly decrease Cathepsin B and DNA fragmentation levels. Caspase levels were elevated slightly in other groups according to control group. While, we also found that creatinine clearance was higher in HS+kefir and HS+low-dose aspirin than HS group. Thus, using low-dose aspirin had been approximately decreased of renal function damage. Kefir decreased renal function damage playing as Angiotensin-converting enzyme inhibitor. But, low-dose aspirin together with kefir worsened rat renal function damage. Cathepsin B might play role both apoptosis and prorenin-processing enzyme. But not caspase pathway may be involved in the present HS diet induced apoptosis. In conclusion, kefir and low-dose aspirin used independently protect renal function and renal damage induced by HS diet in rats.

  2. In vivo measurement of intracellular pH in human brain during different tensions of carbon dioxide in arterial blood. A 31P-NMR study

    DEFF Research Database (Denmark)

    Jensen, K E; Thomsen, C; Henriksen, O

    1988-01-01

    The effect of changes in carbon dioxide tension in arterial blood upon intracellular pH in brain tissue was studied in seven healthy volunteers, aged 22-45 years. The pH changes were monitored by use of 31P nuclear magnetic resonance spectroscopy, performed on a whole-body 1.5 Tesla Siemens imaging...

  3. Myocardial Blood Flow and Flow Reserve in Proximal and Mid-to-Distal Lesions of Left Anterior Descending Artery Measured By N-13 Ammonia PET/CT

    International Nuclear Information System (INIS)

    Cho, Sanggeon; Kim, Ju Han; Cho, Jae Young; Kim, Hyeon Sik; Bom, Heeseung

    2013-01-01

    The purpose of this study is to compare the myocardial blood flow (MBF) and flow reserve (MFR) between proximal and mid-to-distal lesions of the left anterior descending artery (pLAD and mdLAD, respectively) using N-13 ammonia positron emission tomography/computed tomography (PET/CT). Subjects were 11 patients (six men and five women, mean age 64.5 years) with known coronary artery disease (CAD) involving LAD studied by N-13 ammonia PET/CT. They were divided into two groups by the location of stenotic lesions, i.e. pLAD versus mdLAD. Global and regional MBF and MFR were measured and compared. Characteristics of perfusion defects including the number of involved segments, basal area involvement, location, size, and shape were also compared between the two groups. The regional MFR in mid-anterior segment was significantly lower in pLAD group (1.80±0.35 vs 2.76±1.13 for pLAD and mdLAD groups, respectively, p=0.034), while global MFR was not different (2.10±1.10 vs 2.34±0.84). Both stress and rest MBF in LAD territories were not different in both groups. The size of the perfusion defects were significantly larger in pLAD group (44.0±11.5 % vs 21-1±15.8 %, p=0.041). Other characteristics such as location, basal area involvement, and shape were not significantly different between two groups. Conclusions The proximal lesion makes lower MFR in the mid-anterior segment and larger perfusion defect in the LAD territory but comparable MBF compared with mdLAD lesion

  4. Investigating the limitations of single breath-hold renal artery blood flow measurements using spiral phase contrast MR with R-R interval averaging.

    Science.gov (United States)

    Steeden, Jennifer A; Muthurangu, Vivek

    2015-04-01

    1) To validate an R-R interval averaged golden angle spiral phase contrast magnetic resonance (RAGS PCMR) sequence against conventional cine PCMR for assessment of renal blood flow (RBF) in normal volunteers; and 2) To investigate the effects of motion and heart rate on the accuracy of flow measurements using an in silico simulation. In 20 healthy volunteers RAGS (∼6 sec breath-hold) and respiratory-navigated cine (∼5 min) PCMR were performed in both renal arteries to assess RBF. A simulation of RAGS PCMR was used to assess the effect of heart rate (30-105 bpm), vessel expandability (0-150%) and translational motion (x1.0-4.0) on the accuracy of RBF measurements. There was good agreement between RAGS and cine PCMR in the volunteer study (bias: 0.01 L/min, limits of agreement: -0.04 to +0.06 L/min, P = 0.0001). The simulation demonstrated a positive linear relationship between heart rate and error (r = 0.9894, P 100 bpm), or when there is significant motion (vessel expandability: >80%, vessel translation: >x2.2). © 2014 Wiley Periodicals, Inc.

  5. Can cerebral blood flow measurement predict clinical outcome in the acute phase in patients with artherosclerotic occlusive carotid artery disease?

    International Nuclear Information System (INIS)

    Hokari, Masaaki; Yasuda, Hiroshi; Iwasaki, Motoyuki; Iwasaki, Yoshinobu; Abe, Satoru; Saito, Hisatoshi; Kuroda, Satoshi; Nakayama, Naoki

    2010-01-01

    It has been thought that the clinical course of patients with acute carotid occlusive disease depends on their collateral cerebral blood flow (CBF) and duration of ischemia. However, there have been few clinical reports to prove this hypothesis. Therefore, we performed CBF study in patients with artherosclerotic carotid occlusive disease in the very acute phase, and precisely assessed the prognosis of those patients under intensive medical therapy. This prospective study included a total of 44 patients (72±13 years) who were admitted to our hospital between April, 2007 and December, 2008. To evaluate their initial CBF, single photon emission computed tomography (SPECT) studies were performed within 6 hours after the onset. All patients included in this study were medically treated and were periodically followed up by neurological and radiological examination. Moreover, in patients with reduced CBF (ipsilateral CBF/contralateral CBF x 100: %CBF <80%), dobutamine-induce hyperdynamic therapy was performed. Multivariate analysis was performed to detect significant predictors for the occurrence of further cerebral infarction. Multivariate analysis showed that the occurrence of further infarction was associated with older age and smaller %CBF. Of 44 patients, 21 experienced further cerebral infarction within 10 days after onset. Fourteen out of 15 patients with %CBF <60% developed cerebral infarction. This study showed that the prognosis of the patients with artherosclerotic carotid occlusive disease in the acute phase is associated with their initial residual CBFs. It may be difficult to stop the developed cerebral infarction in those patients with %CBF <60% despite intensive medical therapy. (author)

  6. Nanoduct Sweat Conductivity Measurements in 2664 Patients: Relationship to Age, Arterial Blood Gas, Serum Electrolyte Profiles and Clinical Diagnosis

    Science.gov (United States)

    Sezer, Rabia Gonul; Aydemir, Gokhan; Akcan, Abdullah Baris; Paketci, Cem; Karaoglu, Abdulbaki; Aydinoz, Secil; Bozaykut, Abdulkadir

    2013-01-01

    Background The Nanoduct® device has acceptable diagnostic accuracy, but there is not enough systematic data supporting its usage in the diagnosis of cystic fibrosis (CF). Methods A retrospective review of patients with an indication for the sweat test was conducted. The conductivity test was repeated in patients who had values higher than 60 mmol/L, and they were referred for sweat chloride measurements. Associations between sweat conductivity measurements and age, gender, (pH, HCO3, pCO2, Na, K, Cl), family history, consanguinity, indications for the test and number of hospitalization were studied. Results Among 2,664 patients, 16 children had sweat conductivity values higher than 80. The median age of patients diagnosed with CF was 4 months old. Age, pH, HCO3, Na, Cl, K and the sweat conductivity test were statistically related (P conductivity test and the sweat test. Conclusions Patients suspected to have CF can be screened using the Nanoduct® conductivity device in non-qualified centers. PMID:23390474

  7. Measurement of arterial transit time and renal blood flow using pseudocontinuous ASL MRI with multiple post-labeling delays: Feasibility, reproducibility, and variation.

    Science.gov (United States)

    Kim, Dong Won; Shim, Woo Hyun; Yoon, Seong Kuk; Oh, Jong Yeong; Kim, Jeong Kon; Jung, Hoesu; Matsuda, Tsuyoshi; Kim, Dongeun

    2017-09-01

    To evaluate the feasibility, reproducibility, and variation of renal perfusion and arterial transit time (ATT) using pseudocontinuous arterial spin labeling magnetic resonance imaging (PCASL MRI) in healthy volunteers. PCASL MRI at 3T was performed in 25 healthy volunteers on two different occasions. The ATT and ATT-corrected renal blood flow (ATT-cRBF) were calculated at four different post-labeling delay points (0.5, 1.0, 1.5, and 2.0 s) and evaluated for each kidney and subject. The intraclass correlation (ICC) and Bland-Altman plot were used to assess the reproducibility of the PCASL MRI technique. The within-subject coefficient of variance was determined. Results were obtained for 46 kidneys of 23 subjects with a mean age of 38.6 ± 9.8 years and estimated glomerular filtration rate (eGFR) of 89.1 ± 21.2 ml/min/1.73 m 2 . Two subjects failed in the ASL MRI examination. The mean cortical and medullary ATT-cRBF for the subjects were 215 ± 65 and 81 ± 21 ml/min/100 g, respectively, and the mean cortical and medullary ATT were 1141 ± 262 and 1123 ± 245 msec, correspondingly. The ICC for the cortical ATT-cRBF was 0.927 and the within-subject coefficient of variance was 14.4%. The ICCs for the medullary ATT-cRBF and the cortical and medullary ATT were poor. The Bland-Altman plot for cortical RBF showed good agreement between the two measurements. PCASL MRI is a feasible and reproducible method for measuring renal cortical perfusion. In contrast, ATT for the renal cortex and medulla has poor reproducibility and high variation. 2 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:813-819. © 2017 International Society for Magnetic Resonance in Medicine.

  8. Relationship of daily arterial blood pressure monitoring readings and arterial stiffness profile in male patients with chronic obstructive pulmonary disease combined with arterial hypertension

    Directory of Open Access Journals (Sweden)

    Karoli N.A.

    2013-06-01

    Full Text Available The aim of the study was to determine correlation between arterial blood pressure daily rhythm and daily profile of arterial stiffness in male patients with chronic obstructive pulmonary disease (COPD and arterial hypertension. Materials et methods: Prospective investigation comprised 45 male patients with COPD and arterial hypertension. Individuals of 40 years younger and 80 years elder, patients with diabetes, stroke, angina pectoris, or heart infarction, vascular diseases, and exacerbation of chronic disease, bronchial and pulmonary diseases of other etiology were excluded from the analyses. Comparison group included 47 patients with essential arterial hypertension and without chronic respiratory diseases closely similar on general parameters with patients from main clinical series. Twenty-four-hour arterial blood pressure monitoring (ABPM and daily arterial stiffness monitoring were performed using BPLab® MnSDP-2 apparatus (Petr Telegin, Russian Federation. Results: Patients with COPD combined with arterial hypertension with raised arterial stiffness measures prevail over individuals in essential hypertension group. There is pathological alteration of the ABPM circadian rhythm and raised «Pressure load» values in raised arterial stiffness group. Conclusion: We found ABPM raised parameters in patients with COPD and arterial hypertension. It confirms necessity of ABPM in daily arterial stiffness assessment in patients with COPD.

  9. Arterial Stiffness in Children: Pediatric Measurement and Considerations

    Science.gov (United States)

    Savant, Jonathan D.; Furth, Susan L.; Meyers, Kevin E.C.

    2014-01-01

    Background Arterial stiffness is a natural consequence of aging, accelerated in certain chronic conditions, and predictive of cardiovascular events in adults. Emerging research suggests the importance of arterial stiffness in pediatric populations. Methods There are different indices of arterial stiffness. The present manuscript focuses on carotid-femoral pulse wave velocity and pulse wave analysis, although other methodologies are discussed. Also reviewed are specific measurement considerations for pediatric populations and the literature describing arterial stiffness in children with certain chronic conditions (primary hypertension, obesity, diabetes, chronic kidney disease, hypercholesterolemia, genetic syndromes involving vasculopathy, and solid organ transplant recipients). Conclusions The measurement of arterial stiffness in children is feasible and, under controlled conditions, can give accurate information about the underlying state of the arteries. This potentially adds valuable information about the functionality of the cardiovascular system in children with a variety of chronic diseases well beyond that of the brachial artery blood pressure. PMID:26587447

  10. Cerebral blood flow measured by arterial-spin labeling MRI: A useful biomarker for characterization of minimal hepatic encephalopathy in patients with cirrhosis

    International Nuclear Information System (INIS)

    Zheng, Gang; Zhang, Long Jiang; Zhong, Jianhui; Wang, Ze; Qi, Rongfeng; Shi, Donghong; Lu, Guang Ming

    2013-01-01

    Purpose: To investigate the role of arterial-spin labeling (ASL) MRI to non-invasively characterize the patterns of cerebral blood flow (CBF) changes in cirrhotic patients and to assess the potential of ASL MRI to characterize minimal hepatic encephalopathy (MHE). Materials and methods: This study was approved by the local ethics committee, and written informed consent was obtained from all participants. Thirty six cirrhosis patients without overt hepatic encephalopathy (16 MHE patients and 20 non hepatic encephalopathy (non-HE) patients) and 25 controls underwent ASL MRI, and CBF was measured for each subject. One-way ANOCOVA test with age and gender as covariences was used to compare CBF difference among three groups, and post hoc analysis was performed between each two groups. Region-based correlation analysis was applied between Child–Pugh score, venous blood ammonia level, neuropsychological tests and CBF values in cirrhosis patients. Receiver operator characteristic (ROC) analysis was used for assessing CBF measurements in ASL MRI to differentiate MHE from non-HE patients. Results: The gray matter CBF of MHE patients (71.09 ± 11.88 mL min −1 100 g −1 ) was significantly higher than that of non-HE patients (55.28 ± 12.30 mL min −1 100 g −1 , P < 0.01) and controls (52.09 ± 9.27 mL min −1 100 g −1 , P < 0.001). Voxel-wise ANOCOVA results showed that CBFs were significantly different among three groups in multiple gray matter areas (P < 0.05, Bonferroni corrected). Post hoc comparisons showed that CBF of these brain regions was increased in MHE patients compared with controls and non-HE patients (P < 0.05, Bonferroni corrected). CBF of the right putamen was of the highest sensitivity (93.8%) and moderate specificity (75.0%) for characterization of MHE when using the cutoff value of 50.57 mL min −1 100 g −1 . CBFs in the bilateral median cingulate gyri, left supramarginal gyrus, right angular gyrus, right heschl gyrus and right superior

  11. Cerebral blood flow measured by arterial-spin labeling MRI: A useful biomarker for characterization of minimal hepatic encephalopathy in patients with cirrhosis

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Gang [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing, Jiangsu, 210016 (China); Zhang, Long Jiang, E-mail: kevinzhlj@163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); Zhong, Jianhui [Department of Imaging Sciences, University of Rochester School of Medicine and Dentistry, Box648, 601 Elmwood Avenue, Rochester, NY 14642-8648 (United States); Wang, Ze [Department of Psychiatry, Perelman School of Medicine, University of Pennsylvania, 3900 Chestnut St., Philadelphia, PA 19104 (United States); Qi, Rongfeng; Shi, Donghong [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China); Lu, Guang Ming, E-mail: cjr.luguangming@vip.163.com [Department of Medical Imaging, Jinling Hospital, Clinical School of Medical College, Nanjing University, Nanjing, Jiangsu, 210002 (China)

    2013-11-01

    Purpose: To investigate the role of arterial-spin labeling (ASL) MRI to non-invasively characterize the patterns of cerebral blood flow (CBF) changes in cirrhotic patients and to assess the potential of ASL MRI to characterize minimal hepatic encephalopathy (MHE). Materials and methods: This study was approved by the local ethics committee, and written informed consent was obtained from all participants. Thirty six cirrhosis patients without overt hepatic encephalopathy (16 MHE patients and 20 non hepatic encephalopathy (non-HE) patients) and 25 controls underwent ASL MRI, and CBF was measured for each subject. One-way ANOCOVA test with age and gender as covariences was used to compare CBF difference among three groups, and post hoc analysis was performed between each two groups. Region-based correlation analysis was applied between Child–Pugh score, venous blood ammonia level, neuropsychological tests and CBF values in cirrhosis patients. Receiver operator characteristic (ROC) analysis was used for assessing CBF measurements in ASL MRI to differentiate MHE from non-HE patients. Results: The gray matter CBF of MHE patients (71.09 ± 11.88 mL min{sup −1} 100 g{sup −1}) was significantly higher than that of non-HE patients (55.28 ± 12.30 mL min{sup −1} 100 g{sup −1}, P < 0.01) and controls (52.09 ± 9.27 mL min{sup −1} 100 g{sup −1}, P < 0.001). Voxel-wise ANOCOVA results showed that CBFs were significantly different among three groups in multiple gray matter areas (P < 0.05, Bonferroni corrected). Post hoc comparisons showed that CBF of these brain regions was increased in MHE patients compared with controls and non-HE patients (P < 0.05, Bonferroni corrected). CBF of the right putamen was of the highest sensitivity (93.8%) and moderate specificity (75.0%) for characterization of MHE when using the cutoff value of 50.57 mL min{sup −1} 100 g{sup −1}. CBFs in the bilateral median cingulate gyri, left supramarginal gyrus, right angular gyrus, right

  12. Correlation between arterial blood gas analysis and peripheral blood gas analysis in acid-base unbalance state

    Directory of Open Access Journals (Sweden)

    Hyun Lee Kim

    2012-06-01

    Full Text Available Acid-base unbalance is most common problem in severe ill patient, especially in condition of abnormal renal function state. Acid-base unbalances are respiratory acidosis, respiratory alkalosis, metabolic acidosis, and metabolic alkalosis. Metabolic acidosis is frequently appeared in clinical state. Arterial blood gas analysis is considered as a basic test to the intensive care unit patient and emergency state. Recently some researches were done, comparing with arterial blood gas analysis and venous blood gas analysis. Because of venous blood sampling is safer than arterial blood gas analysis, and beside not so different among them for detecting pH, pCO2, HCO3, except pO2 measuring. This research was done in emergency room, and for explaining no different between arterial blood gas analysis and peripheral blood gas analysis result in acid-base unbalance state patient. Especially in kidney functions decreased state. : The study was done from March, 2010 to January, 2011. The object was 89 peoples who came to emergency room for treating internal medicine problem. (Women 53, average age: 66.7±12.1 Then compare between arterial blood gas analysis and peripheral blood gas analysis. Result: The mean arterial minus venous difference for pH, pCO2, and bicarbonate was −0.0170, 2.6528, and 0.6124. Bland-Altman plot was done for predicting agreement of two groups, and the scale was pH −2.95 to 4.17, pCO2 −4.45 to 9.76, bicarbonate −2.95 to 4.16, in 95% relative. Conclusion: The peripheral blood gas pH, pCO2, bicarbonate level is almost same as arterial blood gas analysis results. And enough to measuring acid-base unbalance state, in absent of arterial blood testing.

  13. Evaluation of arterial blood gases and arterial blood pressures in brachycephalic dogs.

    Science.gov (United States)

    Hoareau, G L; Jourdan, G; Mellema, M; Verwaerde, P

    2012-01-01

    Brachycephalic dogs (BD) are prone to congenital upper airway obstruction (brachycephalic syndrome, BS). In humans suffering from sleep apnea, upper airway obstruction is known to cause hypertension. There is no information regarding the influence of BS in dogs on cardiorespiratory physiology. BD are prone to lower P(a) O(2), higher P(a) CO (2), and hypertension compared with meso- or dolicocephalic dogs (MDD). Eleven BD and 11 MDD. After a questionnaire was completed by the owner, a physical examination was performed. Height and thoracic circumferences were measured. Arterial blood gases, electrolyte concentrations, and packed cell volume (PCV) were measured. Systolic (SAP), mean (MAP), and diastolic (DAP) arterial blood pressure recordings were performed. A total of 7 French and 4 English bulldogs met the inclusion criteria. The control group consisted in 6 Beagles, 2 mixed breed dogs, 1 Staffordshire Bull Terrier, 1 Parson Russell Terrier, and 1 Australian Cattle Dog. Statistically, BD had lower P(a) O(2), higher P(a) CO2, and higher PCV when compared with controls (86.2 ± 15.9 versus 100.2 ± 12.6 mmHg, P = .017; 36.3 ± 4.6 versus 32.7 ± 2.6 mmHg, P = .019; 48.2 ± 3.5 versus 44.2 ± 5.4%, P = .026, respectively). Also, they had significantly higher SAP (177.6 ± 25.0 versus 153.5 ± 21.7 mmHg, P = .013), MAP (123.3 ± 17.1 versus 108.3 ± 12.2 mmHg, P = .014), and DAP (95.3 ± 19.2 versus 83.0 ± 11.5 mmHg, P = .042). BD with a P(a) CO (2) >35 mmHg were significantly older than those with a P(a) CO (2) ≤35 mmHg (58 ± 16 and 30 ± 11 months, P = .004). Results of this study suggest that some BD are prone to lower P(a) O(2), higher P(a) CO (2), and hypertension when compared with MDD. Age may be a contributing factor. Copyright © 2012 by the American College of Veterinary Internal Medicine.

  14. Is the measurement of inferior thyroid artery blood flow velocity by color-flow Doppler ultrasonography useful for differential diagnosis between gestational transient thyrotoxicosis and Graves' disease? A prospective study.

    Science.gov (United States)

    Zuhur, Sayid Shafi; Ozel, Alper; Velet, Selvinaz; Buğdacı, Mehmet Sait; Cil, Esra; Altuntas, Yüksel

    2012-01-01

    To determine the role of peak systolic velocity, end-diastolic velocity and resistance indices of both the right and left inferior thyroid arteries measured by color-flow Doppler ultrasonography for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy. The right and left inferior thyroid artery-peak systolic velocity, end-diastolic velocity and resistance indices of 96 patients with thyrotoxicosis (41 with gestational transient thyrotoxicosis, 31 age-matched pregnant patients with Graves' disease and 24 age- and sex-matched non-pregnant patients with Graves' disease) and 25 age and sex-matched healthy euthyroid subjects were assessed with color-flow Doppler ultrasonography. The right and left inferior thyroid artery-peak systolic and end-diastolic velocities in patients with gestational transient thyrotoxicosis were found to be significantly lower than those of pregnant patients with Graves' disease and higher than those of healthy euthyroid subjects. However, the right and left inferior thyroid artery peak systolic and end-diastolic velocities in pregnant patients with Graves' disease were significantly lower than those of non-pregnant patients with Graves' disease. The right and left inferior thyroid artery peak systolic and end-diastolic velocities were positively correlated with TSH-receptor antibody levels. We found an overlap between the inferior thyroid artery-blood flow velocities in a considerable number of patients with gestational transient thyrotoxicosis and pregnant patients with Graves' disease. This study suggests that the measurement of inferior thyroid artery-blood flow velocities with color-flow Doppler ultrasonography does not have sufficient sensitivity and specificity to be recommended as an initial diagnostic test for a differential diagnosis between gestational transient thyrotoxicosis and Graves' disease during pregnancy.

  15. Pulsatile spiral blood flow through arterial stenosis.

    Science.gov (United States)

    Linge, Fabian; Hye, Md Abdul; Paul, Manosh C

    2014-11-01

    Pulsatile spiral blood flow in a modelled three-dimensional arterial stenosis, with a 75% cross-sectional area reduction, is investigated by using numerical fluid dynamics. Two-equation k-ω model is used for the simulation of the transitional flow with Reynolds numbers 500 and 1000. It is found that the spiral component increases the static pressure in the vessel during the deceleration phase of the flow pulse. In addition, the spiral component reduces the turbulence intensity and wall shear stress found in the post-stenosis region of the vessel in the early stages of the flow pulse. Hence, the findings agree with the results of Stonebridge et al. (2004). In addition, the results of the effects of a spiral component on time-varying flow are presented and discussed along with the relevant pathological issues.

  16. DETERMINATION OF AMMONIA IN EAR-LOBE CAPILLARY BLOOD IS AN ALTERNATIVE TO ARTERIAL BLOOD AMMONIA

    NARCIS (Netherlands)

    HUIZENGA, [No Value; GIPS, CH; CONN, HO; JANSEN, PLM

    1995-01-01

    Blood ammonia determination is a laboratory test to diagnose hepatic encephalopathy. Arterial blood is superior to peripheral venous blood ammonia because of ammonia metabolism in muscle. We have compared capillary with arterial whole blood ammonia as capillary sampling is an attractive alternative.

  17. Determination of ammonia in ear-lobe capillary blood is an alternative to arterial blood ammonia

    NARCIS (Netherlands)

    Huizenga, J. R.; Gips, C. H.; Conn, H. O.; Jansen, P. L.

    1995-01-01

    Blood ammonia determination is a laboratory test to diagnose hepatic encephalopathy. Arterial blood is superior to peripheral venous blood ammonia because of ammonia metabolism in muscle. We have compared capillary with arterial whole blood ammonia as capillary sampling is an attractive alternative.

  18. Left coronary arterial blood flow: Noninvasive detection by Doppler US

    International Nuclear Information System (INIS)

    Gramiak, R.; Holen, J.; Moss, A.J.; Gutierrez, O.H.; Picone, A.L.; Roe, S.A.

    1986-01-01

    Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left coronary artery can be distinguished by its blood flow toward the cardiac apex and by specific, functional flow features. Flow patterns vary among the left main, circumflex, and anterior descending arteries; patterns also vary with respiration cycles. In the present study, coronary arterial blood flow was detected in 58 of 70 patients (83%). Findings were validated by selectively injecting an agitated saline contrast medium into the left coronary artery and, in another study, by comparing human Doppler phasic flow waveforms with electromagnetic flowmeter recordings obtained in dogs

  19. Ammonia concentrations in arterial blood, venous blood, and cerebrospinal fluid of dogs with and without congenital extrahepatic portosystemic shunts.

    Science.gov (United States)

    Or, Matan; Devriendt, Nausikaa; Kitshoff, Adriaan M; Peremans, Kathelijne; Vandermeulen, Eva; Paepe, Dominique; Polis, Ingeborgh; Martlé, Valentine; de Rooster, Hilde

    2017-11-01

    OBJECTIVE To compare ammonia concentrations in arterial blood, venous blood, and CSF samples of dogs with and without extrahepatic portosystemic shunts (EHPSS). ANIMALS 19 dogs with congenital EHPSS and 6 healthy control dogs. PROCEDURES All dogs underwent a physical examination and then were anesthetized for transsplenic portal scintigraphy to confirm the presence or absence of EHPSS. While dogs were anesthetized, arterial and venous blood samples and a CSF sample were simultaneously collected for determination of ammonia concentration, which was measured by use of a portable blood ammonia analyzer (device A) and a nonportable biochemical analyzer (device B). Results were compared between dogs with EHPSS and control dogs. RESULTS Arterial, venous, and CSF ammonia concentrations for dogs with EHPSS were significantly greater than those for control dogs. For dogs with EHPSS, ammonia concentrations in both arterial and venous blood samples were markedly increased from the reference range. There was a strong positive correlation between arterial and venous ammonia concentrations and between blood (arterial or venous) and CSF ammonia concentrations. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that blood and CSF ammonia concentrations in dogs with EHPSS were greater than those for healthy dogs and were strongly and positively correlated, albeit in a nonlinear manner. This suggested that the permeability of the blood-brain barrier to ammonia may be abnormally increased in dogs with EHPSS, but further investigation of the relationship between blood or CSF ammonia concentration and clinical signs of hepatic encephalopathy or the surgical outcome for dogs with EHPSS is warranted.

  20. Clinical observations on the effect of carotid artery occlusion on cerebral blood flow mapped by xenon computed tomography and its correlation with carotid artery back pressure

    International Nuclear Information System (INIS)

    Steed, D.L.; Webster, M.W.; DeVries, E.J.; Jungreis, C.A.; Horton, J.A.; Sehkar, L.; Yonas, H.

    1990-01-01

    Xenon computed tomographic cerebral blood flow mapping was correlated with internal carotid artery stump pressures and clinical neurologic assessment during temporary internal carotid artery occlusion. One hundred fourteen patients with skull base tumors or intracranial aneurysms potentially requiring carotid resection or ligation underwent angiography, xenon CT cerebral blood flow mapping, and internal carotid artery blood pressure monitoring. The internal carotid artery was then temporarily occluded with a balloon catheter, stump pressure was measured through the catheter, and the xenon CT cerebral blood flow mapping was repeated. Adequate xenon CT cerebral blood flow was defined as greater than 30 cc/100 gm/min. All patients had normal xenon CT cerebral blood flow before internal carotid artery occlusion. During internal carotid artery occlusion, xenon CT cerebral blood flow was found to be normal (group I, 40 patients), globally reduced but still within the normal range (group II, 50 patients), or low in the distribution of the ipsilateral middle cerebral artery (group III, 13 patients). With balloon occlusion, an immediate neurologic deficit developed in 11 patients (9%) requiring deflation of the balloon preceding xenon CT cerebral blood flow measurement (group IV). In group I internal carotid artery blood pressure was 128 mm Hg. (range 85 to 171 mm Hg) with stump pressure 86 mm Hg (range 46 to 125 mm Hg). In group II internal carotid artery blood pressure was 130 mm Hg. (range 78 to 199 mm Hg), with stump pressure 86 mm Hg (range 31 to 150 mm Hg)

  1. Transcutaneous measurement of the arterial input function in positron emission tomography

    International Nuclear Information System (INIS)

    Litton, J.E.; Eriksson, L.

    1990-01-01

    Positron emission tomography (PET) provides a powerful tool in medical research. Biochemical function can be both precisely localized and quantitatively measured. To achieve reliable quantitation it is necessary to know the time course of activity concentration in the arterial blood during the measurement. In this study the arterial blood curve from the brachial artery is compared to the activity measured in the internal carotid artery with a new transcutaneous detector

  2. Measurement of aortic blood flow by magnetic resonance below and above the origin of the coronary arteries in postmenopausal hormone replacement therapy

    DEFF Research Database (Denmark)

    Sørensen, Morten Beck; Fritz-Hansen, Thomas; Jensen, Henrik Halvor

    2004-01-01

    PURPOSE: Principal blood flow measures might be assessable by velocity-encoded cine magnetic resonance (VENC MR) of aortic blood flow. The feasibility of using VENC MR for clinical research was tested in a contemporary and controversial human model: the effects of 17beta-estradiol (E) and cyclic...

  3. Analysis of Arterial and Venous Blood Gases in Healthy Gyr Falcons ( Falco rusticolus ) Under Anesthesia.

    Science.gov (United States)

    Raghav, Raj; Middleton, Rachael; BSc, Rinshiya Ahamed; Arjunan, Raji; Caliendo, Valentina

    2015-12-01

    Arterial and venous blood gas analysis is useful in the assessment of tissue oxygenation and ventilation and in diagnosis of metabolic and respiratory derangements. It can be performed with a relatively small volume of blood in avian patients under emergency situations. Arterial and venous blood gas analysis was performed in 30 healthy gyr falcons ( Falco rusticolus ) under anaesthesia to establish temperature-corrected reference intervals for arterial blood gas values and to compare them to temperature-corrected venous blood gas values with a portable point-of-care blood gas analyzer (i-STAT 1, Abbott Laboratories, Abbott Park, IL, USA). Statistically significant differences were observed between the temperature-corrected values of pH, partial pressure of carbon dioxide (Pco2), and partial pressure of oxygen (Po2) and the corresponding nontemperature-corrected values of these parameters in both arterial and venous blood. Values of temperature-corrected pH, temperature-corrected Pco2, bicarbonate concentrations, and base excess of extra cellular fluid did not differ significantly between arterial and venous blood, suggesting that, in anesthetized gyr falcons, venous blood gas analysis can be used in place of arterial blood gas analysis in clinical situations. Values for hematocrit, measured by the point-of-care analyzer, were significantly lower compared with those obtained by the microhematocrit method.

  4. Arterialized and venous blood lactate concentration difference during different exercise intensities

    Directory of Open Access Journals (Sweden)

    Leandro C. Felippe

    2017-06-01

    Conclusion: These results suggest a delayed lactate appearance in the venous blood, which is accentuated at higher exercise intensities. The lactate measured in arterialized and venous blood is interchangeable only when blood samples are collected at least 10 minutes after the exercise starts.

  5. Biomarkers of coagulation, fibrinolysis, endothelial function, and inflammation in arterialized venous blood

    DEFF Research Database (Denmark)

    Gram, Anne Sofie; Skov, Jane; Ploug, Thorkil

    2014-01-01

    Effects of venous blood arterialization on cardiovascular risk markers are still unknown. We evaluated biomarkers of inflammation, coagulation, fibrinolysis, and endothelial function in arterialized compared with regular venous blood. Cubital venipunctures were obtained from 10 healthy volunteers....... Arterialization was generated by 10 min heating of the contralateral hand. Concentrations of albumin, C-reactive protein (CRP), tissue-type plasminogen activator (t-PA), plasminogen activator inhibitor type 1 (PAI-1), and von Willebrand factor (vWF) were measured by validated assays. Concentrations of albumin......, CRP, and vWF were significantly lower in arterialized than in venous blood (albumin: 43.8 g/l and 44.8 g/l, P = 0.02). Differences in CRP and vWF became insignificant after adjusting for albumin. The endogenous thrombin potential (ETP) was significantly higher in arterialized than in venous blood...

  6. [Ultrasonographic study of blood flow in the renal arteries of patients with arterial hypertension].

    Science.gov (United States)

    Makarenko, E S; Dombrovskiĭ, V I; Nelasov, N Iu

    2012-01-01

    Vascular duplex ultrasound duplex with simultaneous ECG registration was made to estimate the quantitative and time parameters of blood flow in the renal arteries with grade 1-2 arterial hypertension. There were increases in vascular resistance indices and acceleration phase index and a reduction in systolic phase index. There were correlations of the time parameters of blood flow in the renal arteries with age and lipidogram values.

  7. Continuous intra-arterial blood-gas monitoring

    Science.gov (United States)

    Divers, George A.; Riccitelli, Samuel D.; Blais, Maurice; Hui, Henry K.

    1993-05-01

    Fiber optic technology and optical fluorescence have made the continuous monitoring of arterial blood gases a reality. Practical products that continuously monitor blood gases by use of an invasive sensor are now available. Anesthesiologists and intensive care physicians are beginning to explore the practical implications of this technology. With the advent of intra- arterial blood gas monitors it is possible to assess arterial blood gas values without the labor intensive steps of drawing blood and transporting a blood sample to the lab followed by the actual analysis. These intra-arterial blood gas monitors use new optical sensor technologies that can be reduced in size to the point that the sensor can be inserted into the arterial blood flow through a 20-gauge arterial cannula. In the best of these technologies the sensors accuracy and precision are similar to those in vitro analyzers. This presentation focuses on background technology and in vivo performance of a device developed, manufactured, and marketed by Puritan-Bennett Corporation.

  8. Arterial endothelial function measurement method and apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Maltz, Jonathan S; Budinger, Thomas F

    2014-03-04

    A "relaxoscope" (100) detects the degree of arterial endothelial function. Impairment of arterial endothelial function is an early event in atherosclerosis and correlates with the major risk factors for cardiovascular disease. An artery (115), such as the brachial artery (BA) is measured for diameter before and after several minutes of either vasoconstriction or vasorelaxation. The change in arterial diameter is a measure of flow-mediated vasomodification (FMVM). The relaxoscope induces an artificial pulse (128) at a superficial radial artery (115) via a linear actuator (120). An ultrasonic Doppler stethoscope (130) detects this pulse 10-20 cm proximal to the point of pulse induction (125). The delay between pulse application and detection provides the pulse transit time (PTT). By measuring PTT before (160) and after arterial diameter change (170), FMVM may be measured based on the changes in PTT caused by changes in vessel caliber, smooth muscle tone and wall thickness.

  9. Simultaneous PET/MR imaging of the brain: feasibility of cerebral blood flow measurements with FAIR-TrueFISP arterial spin labeling MRI.

    Science.gov (United States)

    Stegger, Lars; Martirosian, Petros; Schwenzer, Nina; Bisdas, Sotirios; Kolb, Armin; Pfannenberg, Christina; Claussen, Claus D; Pichler, Bernd; Schick, Fritz; Boss, Andreas

    2012-11-01

    Hybrid positron emission tomography/magnetic resonance imaging (PET/MRI) with simultaneous data acquisition promises a comprehensive evaluation of cerebral pathophysiology on a molecular, anatomical, and functional level. Considering the necessary changes to the MR scanner design the feasibility of arterial spin labeling (ASL) is unclear. To evaluate whether cerebral blood flow imaging with ASL is feasible using a prototype PET/MRI device. ASL imaging of the brain with Flow-sensitive Alternating Inversion Recovery (FAIR) spin preparation and true fast imaging in steady precession (TrueFISP) data readout was performed in eight healthy volunteers sequentially on a prototype PET/MRI and a stand-alone MR scanner with 128 × 128 and 192 × 192 matrix sizes. Cerebral blood flow values for gray matter, signal-to-noise and contrast-to-noise ratios, and relative signal change were compared. Additionally, the feasibility of ASL as part of a clinical hybrid PET/MRI protocol was demonstrated in five patients with intracerebral tumors. Blood flow maps showed good delineation of gray and white matter with no discernible artifacts. The mean blood flow values of the eight volunteers on the PET/MR system were 51 ± 9 and 51 ± 7 mL/100 g/min for the 128 × 128 and 192 × 192 matrices (stand-alone MR, 57 ± 2 and 55 ± 5, not significant). The value for signal-to-noise (SNR) was significantly higher for the PET/MRI system using the 192 × 192 matrix size (P change (δS) was significantly lower for the 192 × 192 matrix size (P = 0.02). ASL imaging as part of a clinical hybrid PET/MRI protocol could successfully be accomplished in all patients in diagnostic image quality. ASL brain imaging is feasible with a prototype hybrid PET/MRI scanner, thus adding to the value of this novel imaging technique.

  10. ABO Blood Group and Risk of Thromboembolic and Arterial Disease

    DEFF Research Database (Denmark)

    Vasan, Senthil K; Rostgaard, Klaus; Majeed, Ammar

    2016-01-01

    BACKGROUND: ABO blood groups have been shown to be associated with increased risks of venous thromboembolic and arterial disease. However, the reported magnitude of this association is inconsistent and is based on evidence from small-scale studies. METHODS AND RESULTS: We used the SCANDAT2...... (Scandinavian Donations and Transfusions) database of blood donors linked with other nationwide health data registers to investigate the association between ABO blood groups and the incidence of first and recurrent venous thromboembolic and arterial events. Blood donors in Denmark and Sweden between 1987......-up. Compared with blood group O, non-O blood groups were associated with higher incidence of both venous and arterial thromboembolic events. The highest rate ratios were observed for pregnancy-related venous thromboembolism (incidence rate ratio, 2.22; 95% confidence interval, 1.77-2.79), deep vein thrombosis...

  11. The phosphodiesterase 3 inhibitor cilostazol dilates large cerebral arteries in humans without affecting regional cerebral blood flow

    DEFF Research Database (Denmark)

    Birk, Steffen; Kruuse, Christina Rostrup; Petersen, Kenneth A

    2004-01-01

    in the middle cerebral arteries (VMCA) was measured with transcranial Doppler, and the superficial temporal and radial arteries diameters were measured with ultrasonography. During the 4-hour observation period, there was no effect on systolic blood pressure (P = 0.28), but diastolic blood pressure decreased...

  12. Intraspecific scaling of arterial blood pressure in the Burmese python.

    Science.gov (United States)

    Enok, Sanne; Slay, Christopher; Abe, Augusto S; Hicks, James W; Wang, Tobias

    2014-07-01

    Interspecific allometric analyses indicate that mean arterial blood pressure (MAP) increases with body mass of snakes and mammals. In snakes, MAP increases in proportion to the increased distance between the heart and the head, when the heart-head vertical distance is expressed as ρgh (where ρ is the density of blood, G: is acceleration due to gravity and h is the vertical distance above the heart), and the rise in MAP is associated with a larger heart to normalize wall stress in the ventricular wall. Based on measurements of MAP in Burmese pythons ranging from 0.9 to 3.7 m in length (0.20-27 kg), we demonstrate that although MAP increases with body mass, the rise in MAP is merely half of that predicted by heart-head distance. Scaling relationships within individual species, therefore, may not be accurately predicted by existing interspecific analyses. © 2014. Published by The Company of Biologists Ltd.

  13. Improved calculation of the equilibrium magnetization of arterial blood in arterial spin labeling

    DEFF Research Database (Denmark)

    Ahlgren, André; Wirestam, Ronnie; Knutsson, Linda

    2018-01-01

    PURPOSE: To propose and assess an improved method for calculating the equilibrium magnetization of arterial blood ( M0a), used for calibration of perfusion estimates in arterial spin labeling. METHODS: Whereas standard M0a calculation is based on dividing a proton density-weighted image by an ave...

  14. A new noninvasive device for continuous arterial blood pressure monitoring in the superficial temporal artery

    International Nuclear Information System (INIS)

    Chin, K Y; Panerai, R B

    2013-01-01

    Continuous recording of arterial blood pressure (ABP) has many applications in cardiovascular physiology, but existing alternatives rely on measurements performed in the fingers or radial artery. Peripheral recordings have significant differences from central ABP regarding the pattern of the waveform and corresponding systolic and diastolic values. To address the need for noninvasive measurements closer to the ascending aorta, a new device was constructed to measure ABP in the superficial temporal artery (STA) using photoplethysmography and the arterial volume clamping technique. The optoelectronic circuitry to generate the photoplethysmogram is contained in a specially designed probe placed over the STA and kept in place with a head frame. The prototype (STAbp) also includes original designs for the pneumatic, electronic, signal processing, control and display sub-systems. A self-calibration feature regularly updates the photoplethysmogram operating point to improve accuracy. The performance of the STAbp was compared against the Finapres in 19 healthy subjects. At rest, the bias (SD d ) was −23.1 (15.05), −10.8 (13.83) and −12.4 (12.93) mmHg for systolic, mean and diastolic pressures respectively, without significant differences in drift between the two devices. The 99% bandwidth (SD) for the spectral distribution of ABP waveforms was 5.3 (1.46) Hz for STAbp and 6.8 (0.73) Hz for the Finapres (p < 0.01). Handgrip manoeuvre showed a very similar response to the Finapres, including the rapid return to baseline on release. The new STAbp device has considerable potential as a new tool for clinical and research applications where continuous recording of more central ABP is advantageous compared to peripheral alternatives. (paper)

  15. Arterial versus venous lactate: a measure of sepsis in children.

    Science.gov (United States)

    Samaraweera, Sahan Asela; Gibbons, Berwyck; Gour, Anami; Sedgwick, Philip

    2017-08-01

    This study assessed the agreement between arterial and venous blood lactate and pH levels in children with sepsis. This retrospective, three-year study involved 60 PICU patients, with data collected from electronic or paper patient records. The inclusion criteria comprised of children (≤17 years old) with sepsis and those who had a venous blood gas taken first with an arterial blood gas taken after within one hour. The lactate and pH values measured through each method were analysed. There is close agreement between venous and arterial lactate up to 2 mmol/L. As this value increases, this agreement becomes poor. The limits of agreement (LOA) are too large (±1.90 mmol/L) to allow venous and arterial lactate to be used interchangeably. The mean difference and LOA between both methods would be much smaller if derived using lactate values under 2.0 mmol/L. There is close agreement between arterial and venous pH (MD = -0.056, LOA ± 0.121). However, due to extreme variations in pH readings during sepsis, pH alone is an inadequate marker. A venous lactate ≤2 mmol/L can be used as a surrogate for arterial lactate during early management of sepsis in children. However, if the value exceeds 2 mmol/L, an arterial sample must confirm the venous result. What is known: • In children with septic shock, a blood gas is an important test to show the presence of acidosis and high lactic acid. Hyperlactataemia on admission is an early predictor of outcome and is associated with a greater mortality risk. • An arterial sample is the standard for lactate measurement, however getting a sample may be challenging in the emergency department or a general paediatric ward. Venous samples are quicker and easier to obtain. Adult studies generally advise caution in replacing venous lactate values for the arterial standard, whilst paediatric studies are limited in this area. What is new: • This is the first study assessing the agreement between arterial and peripheral venous

  16. The relationship between total arterial revascularization and blood transfusion following coronary artery bypass grafting.

    Science.gov (United States)

    Djordjevic, Jasmina; Ngaage, Dumbor L

    2015-05-01

    Blood transfusion adversely affects the outcome of coronary artery bypass grafting (CABG), yet blood transfusion after CABG is still common. Total arterial revascularisation (TAR) is increasingly used in current practice but its impact on postoperative blood transfusion is not known. We reviewed the cardiothoracic and blood bank databases and collected data for isolated primary CABG patients from July 2007 to June 2012, excluding patients who had a single graft (n = 148). Perioperative variables of TAR patients (n = 745) were compared with patients who had one or more venous grafts (SVG, n = 1,761) for first-time isolated CABG. The conduits used in TAR patients were predominantly left internal thoracic and radial arteries. Matched group comparison of TAR and SVG patients was performed. The association of TAR with blood transfusion was investigated using multivariate and matched analysis. Of 2,506 patients, the 745 (29.7 %) that had TAR were generally younger, with less complex coronary artery disease and less often diabetic. After correcting for these by 1:1 matching, the mean chest tube drainage and rates of blood transfusion remained significantly lower (p transfused in TAR patients. By multivariate analysis, TAR had an independent effect on reducing blood transfusion after CABG [odds ratio (OR) 0.67, 95 % confidence interval (CI) 0.47-0.97, p = .03]. TAR achieved predominantly with left internal thoracic and radial arteries substantially reduced blood transfusion rates after primary CABG. Further studies are warranted.

  17. Membrane diffusion- and capillary blood volume measurements are not useful as screening tools for pulmonary arterial hypertension in systemic sclerosis: a case control study

    Directory of Open Access Journals (Sweden)

    Spreeuwenberg Marieke D

    2008-10-01

    Full Text Available Abstract Background There is no optimal screening tool for the assessment of pulmonary arterial hypertension (PAH in patients with systemic sclerosis (SSc. A decreasing transfer factor of the lung for CO (TLCO is associated with the development of PAH in SSc. TLCO can be partitioned into the diffusion of the alveolar capillary membrane (Dm and the capillary blood volume (Vc. The use of the partitioned diffusion to detect PAH in SSc is not well established yet. This study evaluates whether Dm and Vc could be candidates for further study of the use for screening for PAH in SSc. Methods Eleven SSc patients with PAH (SScPAH+, 13 SSc patients without PAH (SScPAH- and 10 healthy control subjects were included. Pulmonary function testing took place at diagnosis of PAH. TLCO was partitioned according to Roughton and Forster. As pulmonary fibrosis in SSc influences values of the (partitioned TLCO, these were adjusted for fibrosis score as assessed on HRCT. Results TLCO as percentage of predicted (% was lower in SScPAH+ than in SScPAH- (41 ± 7% vs. 63 ± 12%, p vs. 39 ± 12%, p Conclusion SScPAH+ patients have lower Dm% than SScPAH- patients. There are no correlations between Dm% and hemodynamic parameters of PAH in SScPAH+. These findings do not support further study of the role of partitioning TLCO in the diagnostic work- up for PAH in SSc.

  18. Biochemical characterization of blood plasma of coronary artery ...

    Indian Academy of Sciences (India)

    This study aimed to investigate the biochemical profile of blood plasma of patients with coronary artery disease (CAD) and angiographically normal subjects (controls) to determine biomarkers for their differentiation. In this double blind study, 5 mL venous blood was drawn before angiography from CAD patients (n=60) and ...

  19. Autologous Transfusion of Stored Red Blood Cells Increases Pulmonary Artery Pressure

    Science.gov (United States)

    Pinciroli, Riccardo; Stowell, Christopher P.; Wang, Lin; Yu, Binglan; Fernandez, Bernadette O.; Feelisch, Martin; Mietto, Cristina; Hod, Eldad A.; Chipman, Daniel; Scherrer-Crosbie, Marielle; Bloch, Kenneth D.; Zapol, Warren M.

    2014-01-01

    Rationale: Transfusion of erythrocytes stored for prolonged periods is associated with increased mortality. Erythrocytes undergo hemolysis during storage and after transfusion. Plasma hemoglobin scavenges endogenous nitric oxide leading to systemic and pulmonary vasoconstriction. Objectives: We hypothesized that transfusion of autologous blood stored for 40 days would increase the pulmonary artery pressure in volunteers with endothelial dysfunction (impaired endothelial production of nitric oxide). We also tested whether breathing nitric oxide before and during transfusion could prevent the increase of pulmonary artery pressure. Methods: Fourteen obese adults with endothelial dysfunction were enrolled in a randomized crossover study of transfusing autologous, leukoreduced blood stored for either 3 or 40 days. Volunteers were transfused with 3-day blood, 40-day blood, and 40-day blood while breathing 80 ppm nitric oxide. Measurements and Main Results: The age of volunteers was 41 ± 4 years (mean ± SEM), and their body mass index was 33.4 ± 1.3 kg/m2. Plasma hemoglobin concentrations increased after transfusion with 40-day and 40-day plus nitric oxide blood but not after transfusing 3-day blood. Mean pulmonary artery pressure, estimated by transthoracic echocardiography, increased after transfusing 40-day blood (18 ± 2 to 23 ± 2 mm Hg; P transfusing 3-day blood (17 ± 2 to 18 ± 2 mm Hg; P = 0.5). Breathing nitric oxide decreased pulmonary artery pressure in volunteers transfused with 40-day blood (17 ± 2 to 12 ± 1 mm Hg; P Transfusion of autologous leukoreduced blood stored for 40 days was associated with increased plasma hemoglobin levels and increased pulmonary artery pressure. Breathing nitric oxide prevents the increase of pulmonary artery pressure produced by transfusing stored blood. Clinical trial registered with www.clinicaltrials.gov (NCT 01529502). PMID:25162920

  20. Distribution of ABO Blood Groups and Coronary Artery Calcium.

    Science.gov (United States)

    Wang, Yao; Zhou, Bing-Yang; Zhu, Cheng-Gang; Guo, Yuan-Lin; Wu, Na-Qiong; Qing, Ping; Gao, Ying; Liu, Geng; Dong, Qian; Li, Jian-Jun

    2017-06-01

    ABO blood groups have been confirmed to be associated with cardiovascular diseases such as coronary artery disease. However, whether ABO blood group is correlated with coronary artery calcium (CAC) is still unknown. 301 patients with coronary artery calcium score (CACS) assessed by computed tomography were consecutively enrolled and divided into two groups: with calcium group (CACS>0, n=104) and without calcium group (CACS=0, n=197). Distribution of ABO blood groups was evaluated between the two groups. The percentage of A blood type was significantly higher (p=0.008) and O blood type was significantly lower (p=0.037) in the calcium group. Univariate regression analysis showed that age, total cholesterol, low density lipoprotein cholesterol, high-sensitivity C-reactive protein, A blood type were positively correlated with CAC, and O blood type was inversely associated with CAC. Multivariate regression analysis showed that A blood type was independently associated with CAC (odds ratio: 2.217, 95% confidence interval: 1.260-3.900, p=0.006) even after further adjustment for variables that were clearly different between the two groups. Our data has suggested for the first time that A blood type was an independent risk marker for CAC. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  1. Middle cerebral artery blood velocity and cerebral blood flow and O2 uptake during dynamic exercise

    DEFF Research Database (Denmark)

    Madsen, P L; Sperling, B K; Warming, T

    1993-01-01

    Results obtained by the 133Xe clearance method with external detectors and by transcranial Doppler sonography (TCD) suggest that dynamic exercise causes an increase of global average cerebral blood flow (CBF). These data are contradicted by earlier data obtained during less-well-defined conditions....... To investigate this controversy, we applied the Kety-Schmidt technique to measure the global average levels of CBF and cerebral metabolic rate of oxygen (CMRO2) during rest and dynamic exercise. Simultaneously with the determination of CBF and CMRO2, we used TCD to determine mean maximal flow velocity...... in the middle cerebral artery (MCA Vmean). For values of CBF and MCA Vmean a correction for an observed small drop in arterial PCO2 was carried out. Baseline values for global CBF and CMRO2 were 50.7 and 3.63 ml.100 g-1.min-1, respectively. The same values were found during dynamic exercise, whereas a 22% (P

  2. Relationship between the Direction of Ophthalmic Artery Blood Flow and Ocular Microcirculation before and after Carotid Artery Stenting.

    Science.gov (United States)

    Ishii, Masashi; Hayashi, Morito; Yagi, Fumihiko; Sato, Kenichiro; Tomita, Goji; Iwabuchi, Satoshi

    2016-01-01

    When internal carotid artery stenosis is accompanied by ocular ischemic syndrome, intervention is recommended to prevent irreversible visual loss. In this study, we used laser speckle flowgraphy to measure the ocular microcirculation in the optic nerve head before and after carotid artery stenting (CAS) of 40 advanced internal carotid stenosis lesions from 37 patients. The aim was to investigate the relationship between ocular microcirculation and the direction of ophthalmic artery blood flow obtained by angiography. We found that there was a significant increase in blood flow after CAS ( P = 0.003). Peak systolic velocity as an indicator of the rate of stenosis was also significantly higher in the group with retrograde/undetected flow of the ophthalmic artery than in the group with antegrade flow ( P = 0.002). In all cases where retrograde flow of the ophthalmic artery was observed before stenting, the flow changed to antegrade after stenting. Through the use of laser speckle flowgraphy, this study found that CAS can improve ocular microcirculation. Furthermore, while patients displaying retrograde flow of the ophthalmic artery before stenting have a poor prognosis, CAS corrected the flow to antegrade, suggesting that visual loss can be prevented by improving the ocular microcirculation.

  3. WE-FG-206-05: New Arterial Spin Labeling Method for Simultaneous Estimation of Arterial Cerebral Blood Volume, Cerebral Blood Flow and Arterial Transit Time

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, M; Whitlow, C; Jung, Y [Wake Forest School of Medicine, Winston-Salem, NC (United States); Liu, H [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To demonstrate the feasibility of a novel Arterial Spin Labeling (ASL) method for simultaneously measuring cerebral blood flow (CBF), arterial transit time (ATT), and arterial cerebral blood volume (aCBV) without the use of a contrast agent. Methods: A series of multi-TI ASL images were acquired from one healthy subject on a 3T Siemens Skyra, with the following parameters: PCASL labeling with variable TI [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms, labeling bolus 1400 ms when TI allows, otherwise 100 ms less than TI, TR was minimized for each TI, two sinc shaped pre-saturation pulses were applied in the imaging plane immediately before 2D EPI acquisition. 64×64×24 voxels, 5 mm slice thickness, 1 mm gap, full brain coverage, 6 averages per TI, no crusher gradients, 11 ms TE, scan time of 4:56. The perfusion weighted time-series was created for each voxel and fit to a novel model. The model has two components: 1) the traditional model developed by Buxton et al., accounting for CBF and ATT, and 2) a box car function characterizing the width of the labeling bolus, with variable timing and height in proportion to the aCBV. All three parameters were fit using a nonlinear fitting routine that constrained all parameters to be positive. The main purpose of the high-temporal resolution TI sampling for the first second of data acquisition was to precisely estimate the blood volume component for better detection of arrival time and magnitude of signal. Results: Whole brain maps of CBF, ATT, and aCBV were produced, and all three parameters maps are consistent with similar maps described in the literature. Conclusion: Simultaneous mapping of CBF, ATT, and aCBV is feasible with a clinically tractable scan time (under 5 minutes).

  4. Strength training reduces arterial blood pressure but not sympathetic neural activity in young normotensive subjects

    Science.gov (United States)

    Carter, Jason R.; Ray, Chester A.; Downs, Emily M.; Cooke, William H.

    2003-01-01

    The effects of resistance training on arterial blood pressure and muscle sympathetic nerve activity (MSNA) at rest have not been established. Although endurance training is commonly recommended to lower arterial blood pressure, it is not known whether similar adaptations occur with resistance training. Therefore, we tested the hypothesis that whole body resistance training reduces arterial blood pressure at rest, with concomitant reductions in MSNA. Twelve young [21 +/- 0.3 (SE) yr] subjects underwent a program of whole body resistance training 3 days/wk for 8 wk. Resting arterial blood pressure (n = 12; automated sphygmomanometer) and MSNA (n = 8; peroneal nerve microneurography) were measured during a 5-min period of supine rest before and after exercise training. Thirteen additional young (21 +/- 0.8 yr) subjects served as controls. Resistance training significantly increased one-repetition maximum values in all trained muscle groups (P < 0.001), and it significantly decreased systolic (130 +/- 3 to 121 +/- 2 mmHg; P = 0.01), diastolic (69 +/- 3 to 61 +/- 2 mmHg; P = 0.04), and mean (89 +/- 2 to 81 +/- 2 mmHg; P = 0.01) arterial blood pressures at rest. Resistance training did not affect MSNA or heart rate. Arterial blood pressures and MSNA were unchanged, but heart rate increased after 8 wk of relative inactivity for subjects in the control group (61 +/- 2 to 67 +/- 3 beats/min; P = 0.01). These results indicate that whole body resistance exercise training might decrease the risk for development of cardiovascular disease by lowering arterial blood pressure but that reductions of pressure are not coupled to resistance exercise-induced decreases of sympathetic tone.

  5. Non Newtonian Behavior of Blood in Presence of Arterial Occlusion

    OpenAIRE

    Dr.Arun Kumar Maiti

    2016-01-01

    The objective of the present numerical model is to investigate the effect of shape of stenosis on blood flow through an artery using Bingham plastic fluid model. Blood is modeled as Bingham plastic fluid in a uniform circular tube with an axially symmetric but radially non symmetric stenosis. The expressions for flux, dimensionless resistance to flow with stenosis shape parameter, stenosis length and stenosis size have been shown graphically

  6. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe [Dept. of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Fatouraee, Nasser [Dept. of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Saben, Hazhir [Dept. Radiology, Imaging Center of Imam Khomaini Hospital, Tehran Medical Sciences University, Tehran (Iran, Islamic Republic of)

    2017-04-15

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes.

  7. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    International Nuclear Information System (INIS)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe; Fatouraee, Nasser; Saben, Hazhir

    2017-01-01

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes

  8. Blood pressure and arterial stiffness in obese children and adolescents.

    Science.gov (United States)

    Hvidt, Kristian Nebelin

    2015-03-01

    Obesity, elevated blood pressure (BP) and arterial stiffness are risk factors for cardiovascular disease. A strong relationship exists between obesity and elevated BP in both children and adults. Obesity and elevated BP in childhood track into adult life increasing the risk of cardiovascular disease in adulthood. Ambulatory BP is the most precise measure to evaluate the BP burden, whereas carotid-femoral pulse wave velocity (cfPWV) is regarded as the gold standard for evaluating arterial (i.e. aortic) stiffness. These measures might contribute to a better understanding of obesity's adverse impact on the cardiovascular system, and ultimately a better prevention and treatment of childhood obesity. The overall aim of the present PhD thesis is to investigate arterial stiffness and 24-hour BP in obese children and adolescents, and evaluate whether these measures are influenced by weight reduction. The present PhD thesis is based on four scientific papers.  In a cross-sectional design, 104 severe obese children and adolescents with an age of 10-18 years were recruited when newly referred to the Children's Obesity Clinic, Holbæk University Hospital, and compared to 50 normal weighted age and gender matched control individuals. Ambulatory BP was measured, and cfPWV was investigated in two ways in respect to the distance measure of aorta; the previously recommended length - the so called subtracted distance, and the currently recommended length - the direct distance. In a longitudinal design, the obese patients were re-investigated after one-year of lifestyle intervention at the Children's Obesity Clinic in purpose of reducing the degree of obesity. In the cross-sectional design, the obese group had higher measures of obesity, while matched for age, gender and height, when compared to the control group. In the longitudinal design, 74% of the 72 followed up obese patients experienced a significant weight reduction. CfPWV was dependent on the method used to measure the

  9. A femoral arteriovenous shunt facilitates arterial whole blood sampling in animals

    International Nuclear Information System (INIS)

    Weber, Bruno; Burger, Cyrill; Buck, Alfred; Biro, Peter

    2002-01-01

    In this study we evaluated on-line continuous blood sampling in a femoral arteriovenous (a-v) shunt for use in quantitative tracer studies using gamma-emitting radionuclides in animals. The shunt consisted of 40 cm polyethylene tubing (PE-50) guided through a coincidence probe. Two three-way valves allowed blood pressure measurements and tracer injection. Blood flow in the shunt and the impulse response function (IRF) were assessed using heparinized human blood mixed with fluorine-18 fluorodeoxyglucose (FDG). In vivo experiments were performed in eight male rats (300-350 g) anaesthetized with halothane. In three rats, manual blood sampling was performed in parallel with on-line sampling. In another five animals, the arterial whole blood activity was recorded on-line for 40 min. For the experiments 150-180 MBq FDG was injected over 35 s. Blood flow in the shunt was 23.6, 29.2 and 42.8 ml/h at 100, 120 and 160 mmHg, respectively. The IRF was characterized by minimal dispersion (1-2 s FWHM). Deconvolution of the measured arterial input curves with the IRF changed the measured curve only minimally. Whole blood radioactivity concentration derived from manual and on-line sampling were in excellent agreement. The curves derived from on-line sampling were of high statistical quality. In conclusion, a femoral a-v shunt allows multiple manipulations such as measurement of the arterial whole blood activity, continuous blood pressure monitoring, injection of the tracer and collection of blood samples if necessary. It is not associated with blood loss if the collection of blood samples is not required. It is more convenient to use than manual sampling, the peak of the input curve is never missed and the input curves are of high statistical quality. (orig.)

  10. Magnetization Transfer Effects on the Efficiency of Flow-driven Adiabatic Fast Passage Inversion of Arterial Blood

    OpenAIRE

    Hernandez-Garcia, Luis; Lewis, David P.; Moffat, Bradford; Branch, Craig A.

    2007-01-01

    Continuous arterial spin labeling experiments typically use flow-driven adiabatic fast passage (AFP) inversion of the arterial blood water protons. In this article, we measure the effect of magnetization transfer in blood and how it affects the inversion label. We use modified Bloch equations to model flow-driven adiabatic inversion in the presence of magnetization transfer in blood flowing at velocities from 1 to 30 cm/s in order to explain our findings. Magnetization transfer results in a r...

  11. Implantable blood pressure sensor for analyzing elasticity in arteries

    Science.gov (United States)

    Franco-Ayala, Marco; Martínez-Piñón, Fernando; Reyes-Barranca, Alfredo; Sánchez de la Peña, Salvador; Álvarez-Chavez, José A.

    2009-03-01

    MEMS technology could be an option for the development of a pressure sensor which allows the monitoring of several electronic signals in humans. In this work, a comparison is made between the typical elasticity curves of several arteries in the human body and the elasticity obtained for MEMS silicon microstructures such as membranes and cantilevers employing Finite Element analysis tools. The purpose is to identify which types of microstructures are mechanically compatible with human arteries. The goal is to integrate a blood pressure sensor which can be implanted in proximity with an artery. The expected benefits for this type of sensor are mainly to reduce the problems associated with the use of bulk devices through the day and during several days. Such a sensor could give precise blood pressure readings in a continuous or periodic form, i.e. information that is especially important for some critical cases of hypertension patients.

  12. Nocturnal foot blood flow in patients with arterial insufficiency

    DEFF Research Database (Denmark)

    Jelnes, Rolf; Tønnesen, K H

    1984-01-01

    Twenty-four hour continuous recording of xenon (133Xe) wash-out from the forefoot was performed on patients with normal circulations (n = 10) and on patients with different degrees of arterial insufficiency (n = 36). During day hours the calculated subcutaneous blood flow in the forefoot was on a...

  13. Medida da pressão arterial em crianças e adolescentes: recomendações das diretrizes de hipertensão arterial e prática médica atual Blood pressure measurement in children and adolescents: guidelines of high blood pressure recommendations and current clinical practice

    Directory of Open Access Journals (Sweden)

    Maria Alayde Mendonça da Silva

    2007-04-01

    Full Text Available OBJETIVO: Identificar, em crianças e adolescentes (7 a 17 anos, rede pública e privada de ensino, a freqüência de indivíduos já submetidos à medida da pressão arterial (MPA, o número de vezes, os locais em que foi realizada a aferição e o resultado informado. MÉTODOS: Estudo transversal. Amostragem por conglomerados em 40 escolas, nível fundamental e médio, sorteadas. Cálculo da amostra baseado na prevalência esperada de HAS em crianças e adolescentes. Protocolo: questionário sobre realização prévia de MPA (em caso afirmativo, quantas vezes, quando foi a última medida, o local e o resultado da medida e duas MPA. Variáveis independentes: sexo, faixa etária, classe econômica, escola pública ou privada. RESULTADOS: Amostra constituída de 1253 estudantes 1215 responderam ao questionário (97% 531 do sexo masculino média de 12,4 ± 3 anos. Prevalência de HAS: 7,7% 348 estudantes (29% já haviam medido a PA (54% 1 vez 35% 2 a 4 vezes 11% 5 ou mais 53% há menos de 1 ano. Posto de Saúde, residência, hospital e consultório foram os locais mais mencionados (27%, 16%, 15% e 14%, respectivamente. Houve associação significante entre prévia MPA com faixa etária de 15 a 17 anos, classes econômicas A e B e ser estudante de escola privada. CONCLUSÃO: Apesar das recomendações, há baixa freqüência de MPA (29% em crianças e adolescentes, demonstrando que a mesma não foi ainda incorporada na prática clínica.OBJECTIVE: To determine, in a school-based sample of children and adolescents, aged from 7 to 17 years, of both gender, in public and private schools, the frequency of students already submitted to blood pressure measure. METHODS: A cross-sectional study was carried out, sampling from a population pool of elementary and middle schools, randomly selected. The sample was calculated based on the expected prevalence of hypertension for the age group. Data were collected through a questionnaire. Blood pressure was

  14. Resistance training controls arterial blood pressure in rats with L-NAME- induced hypertension.

    Science.gov (United States)

    Araujo, Ayslan Jorge Santos de; Santos, Anne Carolline Veríssimo dos; Souza, Karine dos Santos; Aires, Marlúcia Bastos; Santana-Filho, Valter Joviniano; Fioretto, Emerson Ticona; Mota, Marcelo Mendonça; Santos, Márcio Roberto Viana

    2013-04-01

    Arterial hypertension is a multifactorial chronic condition caused by either congenital or acquired factors. To evaluate the effects of Resistance Training (RT) on arterial pressure, and on vascular reactivity and morphology, of L-NAME-treated hypertensive rats. Male Wistar rats (200 - 250 g) were allocated into Sedentary Normotensive (SN), Sedentary Hypertensive (SH) and Trained Hypertensive (TH) groups. Hypertension was induced by adding L-NAME (40 mg/Kg) to the drinking water for four weeks. Arterial pressure was evaluated before and after RT. RT was performed using 50% of 1RM, 3 sets of 10 repetitions, 3 times per week for four weeks. Vascular reactivity was measured in rat mesenteric artery rings by concentration-response curves to sodium nitroprusside (SNP); phenylephrine (PHE) was also used for histological and stereological analysis. Resistance training inhibited the increase in mean and diastolic arterial pressures. Significant reduction was observed in Rmax (maximal response) and pD2 (potency) of PHE between SH and TH groups. Arteries demonstrated normal intima, media and adventitia layers in all groups. Stereological analysis demonstrated no significant difference in luminal, tunica media, and total areas of arteries in the SH and TH groups when compared to the SN group. Wall-to-lumen ratio of SH arteries was significantly different compared to SN arteries (parteries. RT was able to prevent an increase in blood pressure under the conditions in this study. This appears to involve a vasoconstrictor regulation mechanism and maintenance of luminal diameter in L-NAME induced hypertensive rats.

  15. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, Flemming; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...... of albumin in arterial and venous blood in seven healthy subjects before and during insulin-induced hypoglycaemia. In both vascular sites blood 51Cr content and the haematocrit increased, plasma volume and intravascular albumin content decreased and the transcapillary escape rate of albumin increased during...

  16. Relationship between retinal blood flow and arterial oxygen.

    Science.gov (United States)

    Cheng, Richard W; Yusof, Firdaus; Tsui, Edmund; Jong, Monica; Duffin, James; Flanagan, John G; Fisher, Joseph A; Hudson, Chris

    2016-02-01

    Vascular reactivity, the response of the vessels to a vasoactive stimulus such as hypoxia and hyperoxia, can be used to assess the vascular range of adjustment in which the vessels are able to compensate for changes in PO2. Previous studies in the retina have not accurately quantified retinal vascular responses and precisely targeted multiple PaO2 stimuli at the same time as controlling the level of carbon dioxide, thus precluding them from modelling the relationship between retinal blood flow and oxygen. The present study modelled the relationship between retinal blood flow and PaO2, showing them to be a combined linear and hyperbolic function. This model demonstrates that the resting tonus of the vessels is at the mid-point and that they have great vascular range of adjustment, compensating for decreases in oxygen above a PETCO2 of 32-37 mmHg but being limited below this threshold. Retinal blood flow (RBF) increases in response to a reduction in oxygen (hypoxia) but decreases in response to increased oxygen (hyperoxia). However, the relationship between blood flow and the arterial partial pressure of oxygen has not been quantified and modelled in the retina, particularly in the vascular reserve and resting tonus of the vessels. The present study aimed to determine the limitations of the retinal vasculature by modelling the relationship between RBF and oxygen. Retinal vascular responses were measured in 13 subjects for eight different blood gas conditions, with the end-tidal partial pressure of oxygen (PETCO2) ranging from 40-500 mmHg. Retinal vascular response measurements were repeated twice; using the Canon laser blood flowmeter (Canon Inc., Tokyo, Japan) during the first visit and using Doppler spectral domain optical coherence tomography during the second visit. We determined that the relationship between RBF and PaO2 can be modelled as a combination of hyperbolic and linear functions. We concluded that RBF compensated for decreases in arterial oxygen content

  17. Aortic-Brachial Pulse Wave Velocity Ratio: A Measure of Arterial Stiffness Gradient Not Affected by Mean Arterial Pressure.

    Science.gov (United States)

    Fortier, Catherine; Desjardins, Marie-Pier; Agharazii, Mohsen

    2018-03-01

    Aortic stiffness, measured by carotid-femoral pulse wave velocity (cf-PWV), is used for the prediction of cardiovascular risk. This mini-review describes the nonlinear relationship between cf-PWV and operational blood pressure, presents the proposed methods to adjust for this relationship, and discusses a potential place for aortic-brachial PWV ratio (a measure of arterial stiffness gradient) as a blood pressure-independent measure of vascular aging. PWV is inherently dependent on the operational blood pressure. In cross-sectional studies, PWV adjustment for mean arterial pressure (MAP) is preferred, but still remains a nonoptimal approach, as the relationship between PWV and blood pressure is nonlinear and varies considerably among individuals due to heterogeneity in genetic background, vascular tone, and vascular remodeling. Extrapolations from the blood pressure-independent stiffness parameter β (β 0 ) have led to the creation of stiffness index β, which can be used for local stiffness. A similar approach has been used for cardio-ankle PWV to generate a blood pressure-independent cardio-ankle vascular index (CAVI). It was recently demonstrated that stiffness index β and CAVI remain slightly blood pressure-dependent, and a more appropriate formula has been proposed to make the proper adjustments. On the other hand, the negative impact of aortic stiffness on clinical outcomes is thought to be mediated through attenuation or reversal of the arterial stiffness gradient, which can also be influenced by a reduction in peripheral medium-sized muscular arteries in conditions that predispose to accelerate vascular aging. Arterial stiffness gradient, assessed by aortic-brachial PWV ratio, is emerging to be at least as good as cf-PWV for risk prediction, but has the advantage of not being affected by operating MAP. The negative impacts of aortic stiffness on clinical outcomes are proposed to be mediated through attenuation or reversal of arterial stiffness gradient

  18. Neonatal oxidative stress depends on oxygen blood pressure in umbilical artery.

    Science.gov (United States)

    Proietti, F; De Bernardo, G; Longini, M; Sordino, D; Scaramuzzini, G; Tataranno, M L; Belvisi, E; Bazzini, F; Perrone, S; Buonocore, G

    2016-01-01

    With advancing gestation, partial pressure of oxygen (pO2) and pH fall significantly. Hypoxia is a main factor inducing free radical generation and thereby oxidative stress (OS). Placental and fetal tissue response when oxygen becomes restricted is complex and partially known. We tested the hypothesis that changes in umbilical artery and vein blood gas concentrations modulate OS occurrence in the newborn. Seventy umbilical artery and vein plasma samples were collected from healthy term newborns immediately after delivery. F2 Isoprostanes (F2-Isop) were measured in all samples as reliable markers of lipid peroxidation. Significantly lower pCO2 and higher pO2 and pH were found in umbilical vein than in artery, as expected. A positive correlation was detected between pH and pO2 only in umbilical artery (p=0.019). F2-Isop levels were no different between artery and vein in cord blood. Significant correlations were found between F2-Isop and pCO2 (p=0.025) as well as between F2-Isop and pH in umbilical vein (p=0.027). F2-Isop correlated with pCO2 (p=0.007) as well as with pO2 values (p=0.005) in umbilical artery blood. Oxidative stress (OS) in newborns depends on oxygen concentrations in umbilical artery. OS biomarkers significantly correlate with pO2 and in umbilical artery but not in umbilical vein. In normoxic conditions fetal-maternal gas exchanges occurring in placenta re-establish normal higher oxygen levels in umbilical vein than artery, with a normal production of free radicals without any deleterious effects.

  19. Parameters of Blood Flow in Great Arteries in Hypertensive ISIAH Rats with Stress-Dependent Arterial Hypertension.

    Science.gov (United States)

    Seryapina, A A; Shevelev, O B; Moshkin, M P; Markel', A L

    2016-08-01

    Magnetic resonance angiography was used to examine blood flow in great arteries of hypertensive ISIAH and normotensive Wistar rats. In hypertensive ISIAH rats, increased vascular resistance in the basin of the abdominal aorta and renal arteries as well as reduced fraction of total renal blood flow were found. In contrast, blood flow through both carotid arteries in ISIAH rats was enhanced, which in suggests more intensive blood supply to brain regulatory centers providing enhanced stress reactivity of these rats characterized by stress-dependent arterial hypertension.

  20. Arterial blood pressure changes in acute T. brucei infection of dogs ...

    African Journals Online (AJOL)

    The aim of this study is to find out the usefulness of serial arterial blood pressure measurements in predicting severity and outcome of acute Trypanosoma brucei infection in dogs. Twenty adult dogs of mixed sexes and aged between 2 and 5 years were used for this study. The dogs were of good cardiac health and were ...

  1. Arterial blood gases and oxygen content in climbers on Mount Everest

    NARCIS (Netherlands)

    Grocott, Michael P. W.; Martin, Daniel S.; Levett, Denny Z. H.; McMorrow, Roger; Windsor, Jeremy; Montgomery, Hugh E.; Ahuja, V.; Aref-Adib, G.; Burnham, R.; Chisholm, A.; Clarke, K.; Coates, D.; Coates, M.; Cook, D.; Cox, M.; Dhillon, S.; Dougall, C.; Doyle, P.; Duncan, P.; Edsell, M.; Edwards, L.; Evans, L.; Gardiner, P.; Grocott, M.; Gunning, P.; Hart, N.; Harrington, J.; Harvey, J.; Holloway, C.; Howard, D.; Hurlbut, D.; Imray, C.; Ince, C.; Jonas, M.; van der Kaaij, J.; Khosravi, M.; Kolfschoten, N.; Levett, D.; Luery, H.; Luks, A.; Martin, D.; McMorrow, R.; Meale, P.; Mitchell, K.; Montgomery, H.; Morgan, G.; Morgan, J.; Murray, A.; Mythen, M.; Newman, S.

    2009-01-01

    BACKGROUND: The level of environmental hypobaric hypoxia that affects climbers at the summit of Mount Everest (8848 m [29,029 ft]) is close to the limit of tolerance by humans. We performed direct field measurements of arterial blood gases in climbers breathing ambient air on Mount Everest. METHODS:

  2. 21 CFR 870.4260 - Cardiopulmonary bypass arterial line blood filter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass arterial line blood filter... Cardiopulmonary bypass arterial line blood filter. (a) Identification. A cardiopulmonary bypass arterial line blood filter is a device used as part of a gas exchange (oxygenator) system to filter nonbiologic...

  3. Predicting Electrocardiogram and Arterial Blood Pressure Waveforms with Different Echo State Network Architectures

    Science.gov (United States)

    2014-11-01

    Predicting Electrocardiogram and Arterial Blood Pressure Waveforms with Different Echo State Network Architectures Allan Fong, MS1,3, Ranjeev...the medical staff in Intensive Care Units. The ability to predict electrocardiogram and arterial blood pressure waveforms can potentially help the...type of neural network for mining, understanding, and predicting electrocardiogram and arterial blood pressure waveforms. Several network

  4. Changes in cerebral artery blood flow velocity after intermittent cerebrospinal fluid drainage.

    OpenAIRE

    Kempley, S T; Gamsu, H R

    1993-01-01

    Doppler ultrasound was used to measure blood flow velocity in the anterior cerebral artery of six premature infants with posthaemorrhagic hydrocephalus, before and after intermittent cerebrospinal fluid (CSF) drainage, on 23 occasions. There was a significant increase in mean blood flow velocity after the drainage procedures (+5.6 cm/s, 95% confidence interval +2.9 to +8.3 cm/s), which was accompanied by a decrease in velocity waveform pulsatility. CSF pressure also fell significantly. In pat...

  5. Arterial cord blood lactate at birth correlates with duration of pushing efforts.

    Science.gov (United States)

    Dessolle, Lionel; Lebrec, Jeremie; Daraï, Emile

    2010-01-01

    To evaluate the impact of the duration of pushing efforts on arterial cord blood lactate values. This was a prospective observational study of 124 consecutive normal vaginal deliveries in a tertiary teaching hospital. Arterial cord blood lactate was determined immediately at birth with a test strip method. Univariate and multivariate analyses were performed to check for clinical determinants of lactate levels. The main measure was lactate according to the duration of pushing efforts. Arterial cord lactates increased significantly and were strongly correlated with the duration of pushing efforts, independent of gestational age and birthweight. Women pushing for more than 20 min had higher arterial cord blood lactates (4.9 +/- 1.4 vs. 3.3 +/- 1.16 mM, respectively) and a higher rate of lactates >6 mM (18 vs. 3%) than those pushing for less than 20 min. At normal delivery, arterial cord blood lactates increase significantly with the duration of pushing efforts. Pushing for more than 20 min is associated with an increased risk of metabolic acidosis in the neonate. Further studies are required to evaluate the clinical significance of these observations. 2009 S. Karger AG, Basel.

  6. Renal artery anatomy affects the blood pressure response to renal denervation in patients with resistant hypertension.

    Science.gov (United States)

    Hering, Dagmara; Marusic, Petra; Walton, Antony S; Duval, Jacqueline; Lee, Rebecca; Sata, Yusuke; Krum, Henry; Lambert, Elisabeth; Peter, Karlheinz; Head, Geoff; Lambert, Gavin; Esler, Murray D; Schlaich, Markus P

    2016-01-01

    Renal denervation (RDN) has been shown to reduce blood pressure (BP), muscle sympathetic nerve activity (MSNA) and target organ damage in patients with resistant hypertension (RH) and bilateral single renal arteries. The safety and efficacy of RDN in patients with multiple renal arteries remains unclear. We measured office and 24-hour BP at baseline, 3 and 6 months following RDN in 91 patients with RH, including 65 patients with single renal arteries bilaterally (group 1), 16 patients with dual renal arteries on either one or both sides (group 2) and 10 patients with other anatomical constellations or structural abnormalities (group 3). Thirty nine out of 91 patients completed MSNA at baseline and follow-up. RDN significantly reduced office and daytime SBP in group 1 at both 3 and 6 months follow-up (Pkidney function in any group. While RDN can be performed safely irrespective of the underlying renal anatomy, the presence of single renal arteries with or without structural abnormalities is associated with a more pronounced BP and MSNA lowering effect than the presence of dual renal arteries in patients with RH. However, when patients with dual renal arteries received renal nerve ablation in all arteries there was trend towards a greater BP reduction. Insufficient renal sympathetic nerve ablation may account for these differences. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  7. SU-G-IeP1-12: Size Selective Arterial Cerebral Blood Volume Mapping Using Multiple Inversion Time Arterial Spin Labeling

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Y; Johnston, M; Whitlow, C [Wake Forest School of Medicine, Winston-salem, NC (United States); Liu, H [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To demonstrate the feasibility of a novel method for size specific arterial cerebral blood volume (aCBV) mapping using pseudo-continuous arterial spin labeling (PCASL), with multiple TI. Methods: Multiple PCASL images were obtained from a subject with TI of [300, 400, 500, 600, 700, 800, 900, 1000, 1500, 2000, 2500, 3000, 3500, 4000] ms. Each TI pair was averaged six times. Two scans were performed: one without a flow crusher gradient and the other with a crusher gradient (10cm/s in three directions) to remove signals from large arteries. Scan times were 5min. without a crusher gradient and 5.5 min with a crusher gradient. Non-linear fitting algorithm finds the minimum mean squared solution of per-voxel based aCBV, cerebral blood flow, and arterial transit time, and fits the data into a hemodynamic model that represents superposition of blood volume and flow components within a single voxel. Results: aCBV maps with a crusher gradient represent signals from medium and small sized arteries, while those without a crusher gradient represent signals from all sized arteries, indicating that flow crusher gradients can be effectively employed to achieve size-specific aCBV mapping. Regardless of flow crusher, the CBF and ATT maps are very similar in appearance. Conclusion: Quantitative size selective blood volume mapping controlled by a flow crusher is feasible without additional information because the ASL quantification process doesn’t require an arterial input function measured from a large artery. The size specific blood volume mapping is not interfered by sSignals from large arteries do not interfere with size specific aCBV mapping in the applications of interest in for applications in which only medium or small arteries are of interest.

  8. Use of paravascular admittance waveforms to monitor relative change in arterial blood pressure

    Science.gov (United States)

    Zielinski, Todd M.; Hettrick, Doug; Cho, Yong

    2010-04-01

    Non-invasive methods to monitor ambulatory blood pressure often have limitations that can affect measurement accuracy and patient adherence [1]. Minimally invasive measurement of a relative blood pressure surrogate with an implantable device may provide a useful chronic diagnostic and monitoring tool. We assessed a technique that uses electrocardiogram and paravascular admittance waveform morphology analysis to one, measure a time duration (vascular tone index, VTI in milliseconds) change from the electrocardiogram R-wave to admittance waveform peak and two, measure the admittance waveform minimum, maximum and magnitude as indicators of change in arterial compliance/distensibility or pulse pressure secondary to change in afterload. Methods: Five anesthetized domestic pigs (32 ± 4.2 kg) were used to study the effects of phenylephrine (1-5 ug/kg/min) on femoral artery pressure and admittance waveform morphology measured with a quadrapolar electrode array catheter placed next to the femoral artery to assess the relative change in arterial compliance due to change in peripheral vascular tone. Results: Statistical difference was observed (p blood pressure may be suitable for implantable devices to detect progression of cardiovascular disease such as hypertension.

  9. Gene expression patterns in peripheral blood correlate with the extent of coronary artery disease.

    Directory of Open Access Journals (Sweden)

    Peter R Sinnaeve

    Full Text Available Systemic and local inflammation plays a prominent role in the pathogenesis of atherosclerotic coronary artery disease, but the relationship of whole blood gene expression changes with coronary disease remains unclear. We have investigated whether gene expression patterns in peripheral blood correlate with the severity of coronary disease and whether these patterns correlate with the extent of atherosclerosis in the vascular wall. Patients were selected according to their coronary artery disease index (CADi, a validated angiographical measure of the extent of coronary atherosclerosis that correlates with outcome. RNA was extracted from blood of 120 patients with at least a stenosis greater than 50% (CADi > or = 23 and from 121 controls without evidence of coronary stenosis (CADi = 0. 160 individual genes were found to correlate with CADi (rho > 0.2, P<0.003. Prominent differential expression was observed especially in genes involved in cell growth, apoptosis and inflammation. Using these 160 genes, a partial least squares multivariate regression model resulted in a highly predictive model (r(2 = 0.776, P<0.0001. The expression pattern of these 160 genes in aortic tissue also predicted the severity of atherosclerosis in human aortas, showing that peripheral blood gene expression associated with coronary atherosclerosis mirrors gene expression changes in atherosclerotic arteries. In conclusion, the simultaneous expression pattern of 160 genes in whole blood correlates with the severity of coronary artery disease and mirrors expression changes in the atherosclerotic vascular wall.

  10. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices.

    Science.gov (United States)

    Martina, Jerson R; Westerhof, Berend E; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F M; de Mol, Bas A J M; Lahpor, Jaap R

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean ± SD) of systolic, diastolic, mean, and pulse pressures were -7.6 ± 5.8, -7.0 ± 5.2, -6.9 ± 5.1, and -0.6 ± 4.5 mm Hg, respectively (all blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)max (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)max (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)max during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.

  11. Relationship of 133Xe cerebral blood flow to middle cerebral arterial flow velocity in men at rest

    Science.gov (United States)

    Clark, J. M.; Skolnick, B. E.; Gelfand, R.; Farber, R. E.; Stierheim, M.; Stevens, W. C.; Beck, G. Jr; Lambertsen, C. J.

    1996-01-01

    Cerebral blood flow (CBF) was measured by 133Xe clearance simultaneously with the velocity of blood flow through the left middle cerebral artery (MCA) over a wide range of arterial PCO2 in eight normal men. Average arterial PCO2, which was varied by giving 4% and 6% CO2 in O2 and by controlled hyperventilation on O2, ranged from 25.3 to 49.9 mm Hg. Corresponding average values of global CBF15 were 27.2 and 65.0 ml 100 g min-1, respectively, whereas MCA blood-flow velocity ranged from 42.8 to 94.2 cm/s. The relationship of CBF to MCA blood-flow velocity over the imposed range of arterial PCO2 was described analytically by a parabola with the equation: CBF = 22.8 - 0.17 x velocity + 0.006 x velocity2 The observed data indicate that MCA blood-flow velocity is a useful index of CBF response to change in arterial PCO2 during O2 breathing at rest. With respect to baseline values measured while breathing 100% O2 spontaneously, percent changes in velocity were significantly smaller than corresponding percent changes in CBF at increased levels of arterial PCO2 and larger than CBF changes at the lower arterial PCO2. These observed relative changes are consistent with MCA vasodilation at the site of measurement during exposure to progressive hypercapnia and also during extreme hyperventilation hypocapnia.

  12. Can flavonoid-rich chocolate modulate arterial elasticity and pathological uterine artery Doppler blood flow in pregnant women? A pilot study.

    Science.gov (United States)

    von Wowern, Emma; Olofsson, Per

    2018-09-01

    Dark chocolate has shown beneficial effects on cardiovascular health and might also modulate hypertensive complications in pregnancy and uteroplacental blood flow. Increased uteroplacental resistance is associated with systemic arterial stiffness. We aimed to investigate the short-term effect of flavonoid-rich chocolate on arterial stiffness and Doppler blood flow velocimetry indexes in pregnant women with compromised uteroplacental blood flow. Doppler blood flow velocimetry and digital pulse wave analysis (DPA) were performed in 25 women pregnant in the second and third trimesters with uterine artery (UtA) score (UAS) 3-4, before and after 3 days of ingestion of chocolate with high flavonoid and antioxidant contents. UtA pulsatility index (PI), UtA diastolic notching, UAS (semiquantitative measure of PI and notching combined), and umbilical artery PI were calculated, and DPA variables representing central and peripheral maternal arteries were recorded. Mean UtA PI (p = .049) and UAS (p = .025) significantly decreased after chocolate consumption. There were no significant changes in UtA diastolic notching or any DPA indexes of arterial stiffness/vascular tone. Chocolate may have beneficial effects on the uteroplacental circulation, but in this pilot study, we could not demonstrate effects on arterial vascular tone as assessed by DPA.

  13. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    International Nuclear Information System (INIS)

    Kyriacou, P A; Shafqat, K; Pal, S K

    2007-01-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO 2 ) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO 2 ) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO 2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  14. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Energy Technology Data Exchange (ETDEWEB)

    Kyriacou, P A [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Shafqat, K [School of Engineering and Mathematical Sciences, City University, London EC1V 0HB (United Kingdom); Pal, S K [St Andrew' s Centre for Plastic Surgery and Burns, Broomfield Hospital, Chelmsford, CM1 7ET (United Kingdom)

    2007-10-15

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO{sub 2}) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO{sub 2}) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO{sub 2} sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures

  15. Arterial blood oxygen saturation during blood pressure cuff-induced hypoperfusion

    Science.gov (United States)

    Kyriacou, P. A.; Shafqat, K.; Pal, S. K.

    2007-10-01

    Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vasoconstriction, oxygenation readings become unreliable or cease. The problem arises because conventional pulse oximetry sensors must be attached to the most peripheral parts of the body, such as finger, ear or toe, where pulsatile flow is most easily compromised. Pulse oximeters estimate arterial oxygen saturation by shining light at two different wavelengths, red and infrared, through vascular tissue. In this method the ac pulsatile photoplethysmographic (PPG) signal associated with cardiac contraction is assumed to be attributable solely to the arterial blood component. The amplitudes of the red and infrared ac PPG signals are sensitive to changes in arterial oxygen saturation because of differences in the light absorption of oxygenated and deoxygenated haemoglobin at these two wavelengths. From the ratios of these amplitudes, and the corresponding dc photoplethysmographic components, arterial blood oxygen saturation (SpO2) is estimated. Hence, the technique of pulse oximetry relies on the presence of adequate peripheral arterial pulsations, which are detected as photoplethysmographic (PPG) signals. The aim of this study was to investigate the effect of pressure cuff-induced hypoperfusion on photoplethysmographic signals and arterial blood oxygen saturation using a custom made finger blood oxygen saturation PPG/SpO2 sensor and a commercial finger pulse oximeter. Blood oxygen saturation values from the custom oxygen saturation sensor and a commercial finger oxygen saturation sensor were recorded from 14 healthy volunteers at various induced brachial pressures. Both pulse

  16. Cerebral blood flow response to changes in arterial carbon dioxide tension during hypothermic cardiopulmonary bypass in children

    International Nuclear Information System (INIS)

    Kern, F.H.; Ungerleider, R.M.; Quill, T.J.; Baldwin, B.; White, W.D.; Reves, J.G.; Greeley, W.J.

    1991-01-01

    We examined the relationship of changes in partial pressure of carbon dioxide on cerebral blood flow responsiveness in 20 pediatric patients undergoing hypothermic cardiopulmonary bypass. Cerebral blood flow was measured during steady-state hypothermic cardiopulmonary bypass with the use of xenon 133 clearance methodology at two different arterial carbon dioxide tensions. During these measurements there was no significant change in mean arterial pressure, nasopharyngeal temperature, pump flow rate, or hematocrit value. Cerebral blood flow was found to be significantly greater at higher arterial carbon dioxide tensions (p less than 0.01), so that for every millimeter of mercury rise in arterial carbon dioxide tension there was a 1.2 ml.100 gm-1.min-1 increase in cerebral blood flow. Two factors, deep hypothermia (18 degrees to 22 degrees C) and reduced age (less than 1 year), diminished the effect carbon dioxide had on cerebral blood flow responsiveness but did not eliminate it. We conclude that cerebral blood flow remains responsive to changes in arterial carbon dioxide tension during hypothermic cardiopulmonary bypass in infants and children; that is, increasing arterial carbon dioxide tension will independently increase cerebral blood flow

  17. The conundrum of arterial stiffness, elevated blood pressure, and aging.

    Science.gov (United States)

    AlGhatrif, Majd; Lakatta, Edward G

    2015-02-01

    Isolated systolic hypertension is a major health burden that is expanding with the aging of our population. There is evidence that central arterial stiffness contributes to the rise in systolic blood pressure (SBP); at the same time, central arterial stiffening is accelerated in patients with increased SBP. This bidirectional relationship created a controversy in the field on whether arterial stiffness leads to hypertension or vice versa. Given the profound interdependency of arterial stiffness and blood pressure, this question seems intrinsically challenging, or probably naïve. The aorta's function of dampening the pulsatile flow generated by the left ventricle is optimal within a physiological range of distending pressure that secures the required distal flow, keeps the aorta in an optimal mechanical conformation, and minimizes cardiac work. This homeostasis is disturbed by age-associated, minute alterations in aortic hemodynamic and mechanical properties that induce short- and long-term alterations in each other. Hence, it is impossible to detect an "initial insult" at an epidemiological level. Earlier manifestations of these alterations are observed in young adulthood with a sharp decline in aortic strain and distensibility accompanied by an increase in diastolic blood pressure. Subsequently, aortic mechanical reserve is exhausted, and aortic remodeling with wall stiffening and dilatation ensue. These two phenomena affect pulse pressure in opposite directions and different magnitudes. With early remodeling, there is an increase in pulse pressure, due to the dominance of arterial wall stiffness, which in turn accelerates aortic wall stiffness and dilation. With advanced remodeling, which appears to be greater in men, the effect of diameter becomes more pronounced and partially offsets the effect of wall stiffness leading to plateauing in pulse pressure in men and slower increase in pulse pressure (PP) than that of wall stiffness in women. The complex nature of

  18. PREDICTION OF BLOOD PATTERN IN S-SHAPED MODEL OF ARTERY UNDER NORMAL BLOOD PRESSURE

    Directory of Open Access Journals (Sweden)

    Mohd Azrul Hisham Mohd Adib

    2013-06-01

    Full Text Available Athletes are susceptible to a wide variety of traumatic and non-traumatic vascular injuries to the lower limb. This paper aims to predict the three-dimensional flow pattern of blood through an S-shaped geometrical artery model. This model has created by using Fluid Structure Interaction (FSI software. The modeling of the geometrical S-shaped artery is suitable for understanding the pattern of blood flow under constant normal blood pressure. In this study, a numerical method is used that works on the assumption that the blood is incompressible and Newtonian; thus, a laminar type of flow can be considered. The authors have compared the results with a previous study with FSI validation simulation. The validation and verification of the simulation studies is performed by comparing the maximum velocity at t = 0.4 s, because at this time, the blood accelerates rapidly. In addition, the resulting blood flow at various times, under the same boundary conditions in the S-shaped geometrical artery model, is presented. The graph shows that velocity increases linearly with time. Thus, it can be concluded that the flow of blood increases with respect to the pressure inside the body.

  19. [Multicenter clinical study on umbilical cord arterial blood gas parameters for diagnosis of neonatal asphyxia].

    Science.gov (United States)

    2010-09-01

    7.18 ± 0.07 (x(-) ± s) and -8.56 ± 4.68 (x(-) ± s) of the non-asphyxiated group (170 cases) respectively (t = 14.3, 8.79, P values ranges of the umbilical artery blood pH corrected values and BE values of the asphyxiated group were ranges, none of selected spots with both high sensitivity and high specificity was found. The statistically normal range of the umbilical artery blood pH and BE for the newborns was 7.20 ± 0.20 (x(-) ± 1.96 s) and -7.64 ± 10.02 (x(-) ± 1.96 s) respectively. Owing to individual differences and the measured blood pH should be clinically corrected, the statistical threshold was not fully equal to the clinicopathological threshold. The pathological threshold of pH or BE for neonatal asphyxia is a range rather than a fixed point. The distributing range of the umbilical artery blood pH clinically corrected values and BE values for neonatal asphyxia were blood gas index should be used flexibly in the above ranges.

  20. Blood pressure

    Science.gov (United States)

    Normal blood pressure is important for proper blood flow to the body's organs and tissues. The force of the blood on the walls of the arteries is called blood pressure. Blood pressure is measured both as the heart ...

  1. Evaluation of arterial digital blood flow using Doppler ultrasonography in healthy dairy cows.

    Science.gov (United States)

    Müller, H; Heinrich, M; Mielenz, N; Reese, S; Steiner, A; Starke, A

    2017-06-06

    Local circulatory disturbances have been implicated in the development of foot disorders in cattle. The goals of this study were to evaluate the suitability of the interdigital artery in the pastern region in both hind limbs using pulsed-wave (PW) Doppler ultrasonography and to investigate quantitative arterial blood flow variables at that site in dairy cows. An Esaote MyLabOne ultrasound machine with a 10-MHz linear transducer was used to assess blood flow in the interdigital artery in the pastern region in both hind limbs of 22 healthy German Holstein cows. The cows originated from three commercial farms and were restrained in a standing hoof trimming chute without sedation. A PW Doppler signal suitable for analysis was obtained in 17 of 22 cows. The blood flow profiles were categorised into four curve types, and the following quantitative variables were measured in three uniform cardiac cycles: vessel diameter, pulse rate, maximum systolic velocity, maximum diastolic velocity, end-diastolic velocity, reverse velocity, maximum time-averaged mean velocity, blood flow rate, resistance index and persistence index. The measurements did not differ among cows from the three farms. Maximum systolic velocity, vessel diameter and pulse rate did not differ but other variables differed significantly among blood flow profiles. Differences in weight-bearing are thought to be responsible for the normal variability of blood flow profiles in healthy cows. The scanning technique used in this report for evaluation of blood flow in the interdigital artery appears suitable for further investigations in healthy and in lame cows.

  2. Plasma volume changes during hypoglycaemia: the effect of arterial blood sampling

    DEFF Research Database (Denmark)

    Hilsted, J; Bendtsen, F; Christensen, N J

    1990-01-01

    To investigate whether previously reported changes in venous blood volume and composition induced by acute hypoglycaemia in humans are representative for the entire body we measured erythrocyte 51Cr content, haematocrit, plasma volume, intravascular albumin content and transcapillary escape rate...... hypoglycaemia. The magnitude of the changes in arterial and venous blood were not significantly different. These results indicate that the above changes in blood volume and composition are whole-body phenomena: furthermore, the major part of the changes are likely to occur in tissues other than upper extremity...

  3. A Pulse Wave Velocity Based Method to Assess the Mean Arterial Blood Pressure Limits of Autoregulation in Peripheral Arteries

    Directory of Open Access Journals (Sweden)

    Ananya Tripathi

    2017-11-01

    Full Text Available Background: Constant blood flow despite changes in blood pressure, a phenomenon called autoregulation, has been demonstrated for various organ systems. We hypothesized that by changing hydrostatic pressures in peripheral arteries, we can establish these limits of autoregulation in peripheral arteries based on local pulse wave velocity (PWV.Methods: Electrocardiogram and plethysmograph waveforms were recorded at the left and right index fingers in 18 healthy volunteers. Each subject changed their left arm position, keeping the right arm stationary. Pulse arrival times (PAT at both fingers were measured and used to calculate PWV. We calculated ΔPAT (ΔPWV, the differences between the left and right PATs (PWVs, and compared them to the respective calculated blood pressure at the left index fingertip to derive the limits of autoregulation.Results: ΔPAT decreased and ΔPWV increased exponentially at low blood pressures in the fingertip up to a blood pressure of 70 mmHg, after which changes in ΔPAT and ΔPWV were minimal. The empirically chosen 20 mmHg window (75–95 mmHg was confirmed to be within the autoregulatory limit (slope = 0.097, p = 0.56. ΔPAT and ΔPWV within a 20 mmHg moving window were not significantly different from the respective data points within the control 75–95 mmHg window when the pressure at the fingertip was between 56 and 110 mmHg for ΔPAT and between 57 and 112 mmHg for ΔPWV.Conclusions: Changes in hydrostatic pressure due to changes in arm position significantly affect peripheral arterial stiffness as assessed by ΔPAT and ΔPWV, allowing us to estimate peripheral autoregulation limits based on PWV.

  4. Quantitative agreement between [(15)O]H2O PET and model free QUASAR MRI-derived cerebral blood flow and arterial blood volume

    NARCIS (Netherlands)

    Heijtel, D. F. R.; Petersen, E. T.; Mutsaerts, H. J. M. M.; Bakker, E.; Schober, P.; Stevens, M. F.; van Berckel, B. N. M.; Majoie, C. B. L. M.; Booij, J.; van Osch, M. J. P.; van Bavel, E. T.; Boellaard, R.; Lammertsma, A. A.; Nederveen, A. J.

    2016-01-01

    The purpose of this study was to assess whether there was an agreement between quantitative cerebral blood flow (CBF) and arterial cerebral blood volume (CBVA) measurements by [(15)O]H2O positron emission tomography (PET) and model-free QUASAR MRI. Twelve healthy subjects were scanned within a week

  5. Some problems of treating acute arterial obstruction using hyperbaric oxygenation ultraviolet irradiation of blood and hemosorption

    International Nuclear Information System (INIS)

    Karyakin, A.M.

    1988-01-01

    Up-to-date state of the problem of acute arterial obstruction (AAO) is considered and clinical observations of patients with acute emboli and thrombosis of abdominal aorta and main arteries of lower extremitics are analyzed. Complex of detoxication therapy and measures on controlling AAO in patients during postoperation period is presented. Complex application of hemosorption, ultraviolet irradiation of autoblood and hyperbaric oxygenation enabled to achieve correction of some indices. Reliable evidences of high therapeutic efficiency of combined application of mentioned methods to patients with reconstructed blood flow are presented. 38 refs.; 3 tabs

  6. Allergic rhinitis and arterial blood pressure: a population-based study.

    Science.gov (United States)

    Sakallioglu, O; Polat, C; Akyigit, A; Cetiner, H; Duzer, S

    2018-05-01

    To investigate the likelihood of allergic rhinitis and potential co-morbidities, and to assess whether allergic rhinitis is associated with arterial blood pressure and hypertension. In this population-based study, 369 adults with allergic rhinitis and asthma were assessed via a questionnaire and immunoglobulin E levels. There were four groups: control (n = 90), allergic rhinitis (n = 99), asthma (n = 87) and hypertension (n = 93). Arterial blood pressure was measured in all groups. There were no significant differences in systolic or diastolic blood pressure between males and females in any group. Pairwise comparisons revealed no significant differences between: the control and allergic rhinitis groups, the control and asthma groups, or the allergic rhinitis and asthma groups. The systolic and diastolic blood pressure values of males and females were significantly higher in the hypertension group than the allergic rhinitis group. There were no significant differences in systolic blood pressure or diastolic blood pressure for seasonal and perennial allergic rhinitis patients. Rhinitis was not associated with increased blood pressure. Allergic rhinitis can coincide with asthma and hypertension. The findings do not support the need for blood pressure follow up in allergic rhinitis patients.

  7. Blood flow quantification from 2D phase contrast MRI in renal arteries using an unsupervised data driven approach

    Energy Technology Data Exchange (ETDEWEB)

    Zoellner, Frank Gerrit [Computer Assisted Clinical Medicine, Faculty of Medicine Mannheim, Univ. of Heidelberg, Mannheim (Germany); Section for Radiology, Dept. of Surgical Sciences, Univ. of Bergen (Norway); Monssen, Jan Ankar [Dept. of Radiology, Haukeland Univ. Hospital, Bergen (Norway); Roervik, Jarie [Section for Radiology, Dept. of Surgical Sciences, Univ. of Bergen (Norway); Dept. of Radiology, Haukeland Univ. Hospital, Bergen (Norway); Lundervold, Arvid [Dept. of Radiology, Haukeland Univ. Hospital, Bergen (Norway); Dept. of Biomedicine, Univ. of Bergen (Norway); Schad, Lothar R. [Computer Assisted Clinical Medicine, Faculty of Medicine Mannheim, Univ. of Heidelberg, Mannheim (Germany)

    2009-07-01

    We present a clustering approach to segment the renal artery from 2D PC Cine MR images to measure arterial blood velocity and flow. Such information is important in grading renal artery stenosis and to support the decision on surgical interventions like percutaneous transluminal angioplasty. Results from 20 data sets (volunteers, 7 patients) show that the renal arteries could be extracted automatically and the corresponding velocity profiles were close (r = 0.977) to that obtained by manual delineations of the vessel areas. (orig.)

  8. Blood flow quantification from 2D phase contrast MRI in renal arteries using an unsupervised data driven approach

    International Nuclear Information System (INIS)

    Zoellner, Frank Gerrit; Monssen, Jan Ankar; Roervik, Jarie; Lundervold, Arvid; Schad, Lothar R.

    2009-01-01

    We present a clustering approach to segment the renal artery from 2D PC Cine MR images to measure arterial blood velocity and flow. Such information is important in grading renal artery stenosis and to support the decision on surgical interventions like percutaneous transluminal angioplasty. Results from 20 data sets (volunteers, 7 patients) show that the renal arteries could be extracted automatically and the corresponding velocity profiles were close (r = 0.977) to that obtained by manual delineations of the vessel areas. (orig.)

  9. Dopexamine increases internal mammary artery blood flow following coronary artery bypass grafting.

    LENUS (Irish Health Repository)

    Flynn, Michael J

    2012-02-03

    OBJECTIVE: Vasoactive agents and inotropes influence conduit-coronary blood flow following coronary artery bypass grafting (CABG). It was hypothesized that dopexamine hydrochloride, a dopamine A-1 (DA-1) and beta(2) agonist would increase conduit-coronary blood flow. A prospective randomized double blind clinical trial was carried out to test this hypothesis. DA-1 receptors have previously been localized to human left ventricle. METHODS: Twenty-six American Society of Anaesthesiology class 2-3 elective coronary artery bypass graft patients who did not require inotropic support on separation from cardiopulmonary bypass (CPB) were studied. According to a randomized allocation patients received either dopexamine (1 microg\\/kg per min) or placebo (saline) by intravenous infusion for 15 min. Immediately prior to and at 5,10 and 15 min of infusion, blood flow through the internal mammary and vein grafts (Transit time flow probes, Transonic Ltd.), heart rate, cardiac index, mean arterial pressure and pulmonary haemodynamics were noted. The data were analysed using multivariate analysis of variance. RESULTS: Low-dose dopexamine (1 microg\\/kg per min) caused a significant increase in mammary graft blood flow compared to placebo at 15 min of infusion (P=0.028, dopexamine group left internal mammary artery (LIMA) flow of 43.3+\\/-14.2 ml\\/min, placebo group LIMA flow at 26.1+\\/-16.3 ml\\/min). Dopexamine recipients demonstrated a non-significant trend to increased saphenous vein graft flow (P=0.059). Increased heart rate was the only haemodynamic change induced by dopexamine (P=0.004, dopexamine group at 85.2+\\/-9.6 beats\\/min and placebo group at 71.1+\\/-7.6 beats\\/min after 15 min of infusion). CONCLUSION: This study demonstrates that administration of dopexamine (1 microg\\/kg per min) was associated with a significant increase in internal mammary artery graft blood flow with mild increase in heart rate being the only haemodynamic change. Low-dose dopexamine may

  10. The effects of fenoldopam on coronary conduit blood flow after coronary artery bypass graft surgery.

    LENUS (Irish Health Repository)

    Halpenny, M

    2012-02-03

    OBJECTIVE: To quantify the effects of fenoldopam, 0.1 microg\\/kg\\/min, on left internal mammary artery (LIMA) and saphenous vein blood flow after coronary anastomosis. DESIGN: Prospective, randomized, double-blind, placebo-controlled trial. SETTING: University teaching hospital, single institution. PARTICIPANTS: Thirty-one American Society of Anesthesiologists III patients undergoing elective coronary revascularization. INTERVENTIONS: A perivascular ultrasonic flow probe (Linton Instrumentation, Norfolk, UK) was placed around the LIMA and saphenous vein graft after coronary anastomosis. MEASUREMENTS AND MAIN RESULTS: Immediately before and at 5-minute intervals for 15 minutes after starting the infusion, blood flow was measured in the LIMA and one saphenous vein graft using a transit time ultrasonic flow probe. Heart rate, blood pressure, and central venous pressure were documented at these time points. Administration of fenoldopam, 0.1 microg\\/kg\\/min, did not alter heart rate or blood pressure. A small, nonsignificant increase in LIMA blood flow occurred during the 15-minute study period (30 +\\/- 12 to 35 +\\/- 10 mL\\/min) in patients who received fenoldopam. No significant changes occurred in the placebo group. CONCLUSIONS: The findings indicate that fenoldopam, 0.1 microg\\/kg\\/min, did not influence coronary conduit blood flow to a clinically significant extent. The small increase in LIMA blood flow may be of greater importance in high-risk patients or in the prevention of coronary arterial spasm.

  11. Analysis of damping characteristics of arterial catheter blood ...

    African Journals Online (AJOL)

    working diagnosis, site of arterial cannula, date and time of insertion, hours since insertion, type of cannula (manufacturer, gauge, length). The CoD was measured using the 'fast flush' method described by .... THC-B & WHR: Design, data collection, analysis, manuscript preparation. JDT: Data collection and analysis.

  12. Longitudinal fasting blood glucose patterns and arterial stiffness risk in a population without diabetes.

    Science.gov (United States)

    Wu, Yuntao; Yu, Junxing; Jin, Cheng; Li, Yun; Su, Jinmei; Wei, Guoqing; Zheng, Xiaoming; Gao, Jingsheng; Gao, Wenyuan; Wu, Shouling

    2017-01-01

    To identify long-term fasting blood glucose trajectories and to assess the association between the trajectories and the risk of arterial stiffness in individuals without diabetes. We enrolled 16,454 non-diabetic participants from Kailuan cohort. Fasting blood glucose concentrations were measured in 2006, 2008, and 2010 survey. Brachial-ankle pulse wave velocities were measured during 2011 to 2016. Multivariate regression model was used to estimate the difference of brachial-ankle pulse wave velocity levels and logistic regression was used to calculate odds ratios (ORs) and 95% confidence intervals (95%CIs) of arterial stiffness risk, according to the fasting blood glucose trajectories. We identified five distinct fasting blood glucose trajectories and each of the trajectories was labeled according to its range and change over 2006-2010 survey: elevated-stable pattern (5.0% of participants), elevated-decreasing pattern (6.6%), moderate-increasing pattern (10.9%), moderate-stable pattern (59.3%), and low-stable pattern (18.2%). After adjustment for potential confounders, individuals with elevated-stable pattern had a 42.6 cm/s (95%CI: 24.7 to 60.6 cm/s) higher brachial-ankle pulse wave velocity level and a 37% (OR 1.37, 95%CI: 1.14 to 1.66) higher arterial stiffness risk, and individuals with moderate-increasing pattern had a 19.6 cm/s (95%CI: 6.9 to 32.3 cm/s) higher brachial-ankle pulse wave velocity level and a 17% (OR 1.17, 95%CI: 1.03 to 1.33) higher arterial stiffness risk, related to individuals with moderate-stable pattern. We did not find significant associations of the elevated-decreasing or low-stable patterns with arterial stiffness. Consistently, the cumulative average, variability, and increased rate of fasting blood glucose during 2006-2010 survey were significantly associated with the arterial stiffness risk. Discrete fasting blood glucose trajectories were associated with the arterial stiffness risk in non-diabetic individuals.

  13. Blood Pressure and Arterial Load After Transcatheter Aortic Valve Replacement for Aortic Stenosis.

    Science.gov (United States)

    Lindman, Brian R; Otto, Catherine M; Douglas, Pamela S; Hahn, Rebecca T; Elmariah, Sammy; Weissman, Neil J; Stewart, William J; Ayele, Girma M; Zhang, Feifan; Zajarias, Alan; Maniar, Hersh S; Jilaihawi, Hasan; Blackstone, Eugene; Chinnakondepalli, Khaja M; Tuzcu, E Murat; Leon, Martin B; Pibarot, Philippe

    2017-07-01

    After aortic valve replacement, left ventricular afterload is often characterized by the residual valve obstruction. Our objective was to determine whether higher systemic arterial afterload-as reflected in blood pressure, pulsatile and resistive load-is associated with adverse clinical outcomes after transcatheter aortic valve replacement (TAVR). Total, pulsatile, and resistive arterial load were measured in 2141 patients with severe aortic stenosis treated with TAVR in the PARTNER I trial (Placement of Aortic Transcatheter Valve) who had systolic blood pressure (SBP) and an echocardiogram obtained 30 days after TAVR. The primary end point was 30-day to 1-year all-cause mortality. Lower SBP at 30 days after TAVR was associated with higher mortality (20.0% for SBP 100-129 mm Hg versus 12.0% for SBP 130-170 mm Hg; P <0.001). This association remained significant after adjustment, was consistent across subgroups, and confirmed in sensitivity analyses. In adjusted models that included SBP, higher total and pulsatile arterial load were associated with increased mortality ( P <0.001 for all), but resistive load was not. Patients with low 30-day SBP and high pulsatile load had a 3-fold higher mortality than those with high 30-day SBP and low pulsatile load (26.1% versus 8.1%; hazard ratio, 3.62; 95% confidence interval, 2.36-5.55). Even after relief of valve obstruction in patients with aortic stenosis, there is an independent association between post-TAVR blood pressure, systemic arterial load, and mortality. Blood pressure goals in patients with a history of aortic stenosis may need to be redefined. Increased pulsatile arterial load, rather than blood pressure, may be a target for adjunctive medical therapy to improve outcomes after TAVR. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00530894. © 2017 American Heart Association, Inc.

  14. Roles of Arterial Stiffness and Blood Pressure in Hypertension-Associated Cognitive Decline in Healthy Adults.

    Science.gov (United States)

    Hajjar, Ihab; Goldstein, Felicia C; Martin, Greg S; Quyyumi, Arshed A

    2016-01-01

    Although there is strong evidence that hypertension leads to cognitive decline, especially in the executive domain, the relationship between blood pressure and cognition has been conflicted. Hypertension is characterized by blood pressure elevation and increased arterial stiffness. We aimed at investigating whether arterial stiffness would be superior to blood pressure in predicting cognitive decline and explaining the hypertension-executive decline association. A randomly selected asymptomatic population (n=591, age=49.2 years, 70% women, 27% black, and education=18 years) underwent annual vascular and cognitive assessments. Cognition was assessed using computerized versions commonly used cognitive tests, and principal component analysis was used for deriving cognitive scores for executive function, memory, and working memory. Arterial stiffness was measured by carotid-femoral pulse wave velocity (PWV). Higher PWV, but not blood pressure, was associated with a steeper decline in executive (P=0.0002), memory (P=0.05), and working memory (P=0.02) scores after adjusting for demographics, education, and baseline cognitive performance. This remained true after adjusting for hypertension. Hypertension was associated with greater decline in executive score (P=0.0029) and those with combined hypertension and elevated PWV (>7 m/s) had the greatest decline in executive score (P value hypertension×PWV=0.02). PWV explained the association between hypertension and executive function (P value for hypertension=0.0029 versus 0.24 when adjusting for PWV). In healthy adults, increased arterial stiffness is superior to blood pressure in predicting cognitive decline in all domains and in explaining the hypertension-executive function association. Arterial stiffness, especially in hypertension, may be a target in the prevention of cognitive decline. © 2015 American Heart Association, Inc.

  15. Evaluation of Blood Hemodynamics in Vascular Grafts after Total Arterial Coronary Revascularization

    Directory of Open Access Journals (Sweden)

    Ahmad Ali Amirghofran

    2016-07-01

    Full Text Available Arterial grafting has increasingly been advocated for the treatment of coronary artery disease in an attempt to improve the long-term results. In the quest to perform routine total arterial revascularization, composite Y graft methods are gaining popularity. The aim of our study was to evaluate whether blood flow in the left internal thoracic artery can provide sufficient perfusion to the entire cardiac muscle per se. Twenty patients with severe coronary artery stenosis who underwent complete arterial coronary revascularization using a composite graft entered our study. Blood flow in thoracic trunk was evaluated in three phases: cross-clamp on, cross-clamp off, and after weaning the patient from cardiopulmonary bypass. Mean arterial blood pressure in the thoracic trunk in these various positions was 62.7±3.7. left internal thora cic artery can provide sufficient blood flow to the cardiac muscles for both rest and exercise conditions.

  16. Arterial blood gas reference values for sea level and an altitude of 1,400 meters.

    Science.gov (United States)

    Crapo, R O; Jensen, R L; Hegewald, M; Tashkin, D P

    1999-11-01

    Blood gas measurements were collected on healthy lifetime nonsmokers at sea level (n = 96) and at an altitude of 1,400 meters (n = 243) to establish reference equations. At each study site, arterial blood samples were analyzed in duplicate on two separate blood gas analyzers and CO-oximeters. Arterial blood gas variables included Pa(O(2)), Pa(CO(2)), pH, and calculated alveolar-arterial PO(2) difference (AaPO(2)). CO-oximeter variables were Hb, COHb, MetHb, and Sa(O(2)). Subjects were 18 to 81 yr of age with 166 male and 173 female. Outlier data were excluded from multiple regression analysis, and reference equations were fitted to the data in two ways: (1) best fit using linear, squared, and cross-product terms; (2) simple equations, including only the variables that explained at least 3% of the variance. Two sets of equations were created: (1) using only the sea level data and (2) using the combined data with barometric pressure as an independent variable. Comparisons with earlier studies revealed small but significant differences; the decline in Pa(O(2)) with age at each altitude was consistent with most previous studies. At sea level, the equation that included barometric pressure predicted Pa(O(2)) slightly better than the sea level specific equation. The inclusion of barometric pressure in the equations allows better prediction of blood gas reference values at sea level and at altitudes as high as 1,400 meters.

  17. Evaluation of the carotid artery stenosis based on minimization of mechanical energy loss of the blood flow.

    Science.gov (United States)

    Sia, Sheau Fung; Zhao, Xihai; Li, Rui; Zhang, Yu; Chong, Winston; He, Le; Chen, Yu

    2016-11-01

    Internal carotid artery stenosis requires an accurate risk assessment for the prevention of stroke. Although the internal carotid artery area stenosis ratio at the common carotid artery bifurcation can be used as one of the diagnostic methods of internal carotid artery stenosis, the accuracy of results would still depend on the measurement techniques. The purpose of this study is to propose a novel method to estimate the effect of internal carotid artery stenosis on the blood flow based on the concept of minimization of energy loss. Eight internal carotid arteries from different medical centers were diagnosed as stenosed internal carotid arteries, as plaques were found at different locations on the vessel. A computational fluid dynamics solver was developed based on an open-source code (OpenFOAM) to test the flow ratio and energy loss of those stenosed internal carotid arteries. For comparison, a healthy internal carotid artery and an idealized internal carotid artery model have also been tested and compared with stenosed internal carotid artery in terms of flow ratio and energy loss. We found that at a given common carotid artery bifurcation, there must be a certain flow distribution in the internal carotid artery and external carotid artery, for which the total energy loss at the bifurcation is at a minimum; for a given common carotid artery flow rate, an irregular shaped plaque at the bifurcation constantly resulted in a large value of minimization of energy loss. Thus, minimization of energy loss can be used as an indicator for the estimation of internal carotid artery stenosis.

  18. Simple Radiowave-Based Method For Measuring Peripheral Blood Flow Project

    Science.gov (United States)

    Oliva-Buisson, Yvette J.

    2014-01-01

    Project objective is to design small radio frequency based flow probes for the measurement of blood flow velocity in peripheral arteries such as the femoral artery and middle cerebral artery. The result will be the technological capability to measure peripheral blood flow rates and flow changes during various environmental stressors such as microgravity without contact to the individual being monitored. This technology may also lead to an easier method of detecting venous gas emboli during extravehicular activities.

  19. Downstream Hepatic Arterial Blood Pressure Changes Caused by Deployment of the Surefire AntiReflux Expandable Tip

    International Nuclear Information System (INIS)

    Rose, Steven C.; Kikolski, Steven G.; Chomas, James E.

    2013-01-01

    Purpose: The purpose of this work was to evaluate blood pressure changes caused by deployment of the Surefire antireflux expandable tip. The pressure measurements are relevant because they imply changes in hepatoenteric arterial blood flow within this liver compartment during hepatic artery delivery of cytotoxic agents. Methods: After positioning the Surefire antireflux system in the targeted hepatic artery, blood pressure was obtained initially with the tip collapsed (or through a femoral artery sheath), then again after the tip was expanded before chemoembolization or yttrium 90 ( 90 Y) radioembolization. Results: Eighteen patients with liver malignancy underwent 29 procedures in 29 hepatic arteries (3 common hepatic, 22 lobar, 4 segmental). Systolic, diastolic, and mean blood pressure were all decreased by a mean of 29 mm Hg (p = 0.000004), 14 mm Hg (p = 0.0000004), and 22 mm Hg (p = 0.00000001), respectively. Conclusion: When the Surefire expandable tip is deployed to prevent retrograde reflux of agents, it also results in a significant decrease in blood pressure in the antegrade distribution, potentially resulting in hepatopedal blood flow in vessels that are difficult to embolize, such as the supraduodenal arteries

  20. Magnetic Resonance Imaging Measurement of Left Ventricular Blood Flow and Coronary Flow Reserve in Patients with Chronic Heart Failure due to Coronary Artery Disease

    Energy Technology Data Exchange (ETDEWEB)

    Aras, A.; Anik, Y.; Demirci, A.; Balci, N.C.; Kozdag, G.; Ural, D.; Komsuoglu, B. (Radiology Dept. and Cardiology Dept., Kocaeli Univ. School of Medicine, Kocaeli (Turkey))

    2007-11-15

    Background: Coronary sinus flow reflects global cardiac perfusion and has been used for the assessment of myocardial flow reserve, which is reduced in chronic heart failure (CHF). Coronary flow reserve (CFR) can be measured by using phase-contrast (PC) velocity-encoded cine (VEC) magnetic resonance imaging (MRI). Purpose: To quantify and compare global left ventricular (LV) perfusion and CFR in patients with CHF and in a healthy control group by measuring coronary sinus flow with PC VEC MRI, and to correlate this with global LV perfusion, segmental first-pass perfusion, and viability in the same patients. Material and Methods: Cardiac MRI was performed in 20 patients with CHF of ischemic origin and in a control group of healthy subjects (n 11) at rest and after pharmacological stress induced by i.v. dipyridamole. The MRI protocol included cine MRI, VEC MRI, first-pass perfusion, and delayed contrast-enhanced MRI for viability. Global LV perfusion was quantified by measuring coronary sinus flow on VEC MRI at rest in all subjects. CFR was determined as the ratio of global LV perfusion before and after pharmacologic stress. Results: At rest, global LV perfusion was not significantly different in patients with CHF and the control group. After administration of dipyridamole, global LV perfusion and CFR were significantly lower in patients with CHF compared to the control group (P<0.001). An inverse correlation was observed between CFR and the number of infarcted and/or ischemic segments (P = 0.083, P = 0.037). Conclusion: A combined cardiac MRI protocol including function and perfusion techniques together with VEC MRI can be used to evaluate global LV perfusion and CFR in patients with CHF. Global LV perfusion and CFR measurements may have potential in the monitoring of CHF. Impaired CFR may contribute to progressive decline in LV function in patients with CHF

  1. Magnetic Resonance Imaging Measurement of Left Ventricular Blood Flow and Coronary Flow Reserve in Patients with Chronic Heart Failure due to Coronary Artery Disease

    International Nuclear Information System (INIS)

    Aras, A.; Anik, Y.; Demirci, A.; Balci, N.C.; Kozdag, G.; Ural, D.; Komsuogl u, B.

    2007-01-01

    Background: Coronary sinus flow reflects global cardiac perfusion and has been used for the assessment of myocardial flow reserve, which is reduced in chronic heart failure (CHF). Coronary flow reserve (CFR) can be measured by using phase-contrast (PC) velocity-encoded cine (VEC) magnetic resonance imaging (MRI). Purpose: To quantify and compare global left ventricular (LV) perfusion and CFR in patients with CHF and in a healthy control group by measuring coronary sinus flow with PC VEC MRI, and to correlate this with global LV perfusion, segmental first-pass perfusion, and viability in the same patients. Material and Methods: Cardiac MRI was performed in 20 patients with CHF of ischemic origin and in a control group of healthy subjects (n 11) at rest and after pharmacological stress induced by i.v. dipyridamole. The MRI protocol included cine MRI, VEC MRI, first-pass perfusion, and delayed contrast-enhanced MRI for viability. Global LV perfusion was quantified by measuring coronary sinus flow on VEC MRI at rest in all subjects. CFR was determined as the ratio of global LV perfusion before and after pharmacologic stress. Results: At rest, global LV perfusion was not significantly different in patients with CHF and the control group. After administration of dipyridamole, global LV perfusion and CFR were significantly lower in patients with CHF compared to the control group (P<0.001). An inverse correlation was observed between CFR and the number of infarcted and/or ischemic segments (P = 0.083, P 0.037). Conclusion: A combined cardiac MRI protocol including function and perfusion techniques together with VEC MRI can be used to evaluate global LV perfusion and CFR in patients with CHF. Global LV perfusion and CFR measurements may have potential in the monitoring of CHF. Impaired CFR may contribute to progressive decline in LV function in patients with CHF

  2. Middle cerebral artery thrombosis: acute blood-brain barrier consequences

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, W.D.; Prado, R.; Watson, B.D.; Nakayama, H.

    1988-07-01

    The effect of middle cerebral artery (MCA) thrombosis on the integrity of the blood-brain barrier (BBB) was studied in rats using horseradish peroxidase (HRP). Endothelial injury with subsequent platelet thrombosis was produced by means of a rose bengal-sensitized photochemical reaction, facilitated by irradiating the right proximal MCA segment with the focused beam of an argon laser. At 15 minutes following thrombosis formation, diffuse leakage of HRP was observed bilaterally within cortical and subcortical brain areas. Peroxidase extravasation was most dense within the territory of the occluded artery including neocortical areas and dorso-lateral striatum. Contralaterally, a similar distribution was observed but with less intense HRP leakage. Ultrastructural studies demonstrated an increase in permeability to HRP within arterioles, venules and capillaries. At these sites, the vascular endothelium contained HRP-filled pinocytotic vesicles and tubular profiles. Although less intense, bilateral HRP leakage was also observed following MCA stenosis or femoral artery occlusion. Endothelial-platelet interactions at the site of vascular injury may be responsible for releasing substances or neurohumoral factors which contribute to the acute opening of the BBB.

  3. Induced renal artery stenosis in rabbits: magnetic resonance imaging, angiography, and radionuclide determination of blood volume and blood flow

    International Nuclear Information System (INIS)

    Mitchell, D.G.; Tobin, M.; LeVeen, R.; Tomaczewski, J.; Alavi, A.; Staum, M.; Kundel, H.

    1988-01-01

    To investigate the ability of MRI to detect alterations due to renal ischemia, a rabbit renal artery stenosis (RAS) model was developed. Seven rabbits had RAS induced by surgically encircling the artery with a polyethylene band which had a lumen of 1 mm, 1 to 2 weeks prior to imaging. The stenosis was confirmed by angiography, and the rabbits were then imaged in a 1.4 T research MRI unit. T1 was calculated using four inversion recovery sequences with different inversion times. Renal blood flow, using 113 Sn-microspheres, and regional water content by drying were then measured. The average T1 of the inner medulla was shorter for the ischemia (1574 msec) than for the contralateral kidney (1849 msec), while no change ws noted in the cortex. Ischemic kidneys had less distinct outer medullary zones on IR images with TI = 600 msec than did contralateral or control kidneys. Blood flow to both the cortex and medulla were markedly reduced in ischemic kidneys compared with contralateral kidneys (119.5 vs. 391 ml/min/100 gm for cortex and 19.8 vs. 50.8 ml/min/100 gm for medulla). Renal water and blood content were less affected. Our rabbit model of renal artery stenosis with MRI, radionuclide, and angiographic correlation has the potential to increase our understanding of MR imaging of the rabbit kidney

  4. Aortic blood flow subtraction: an alternative method for measuring total renal blood flow in conscious dogs

    DEFF Research Database (Denmark)

    Sandgaard, N C F; Andersen, J L; Holstein-Rathlou, N-H

    2002-01-01

    We have measured total renal blood flow (TRBF) as the difference between signals from ultrasound flow probes implanted around the aorta above and below the renal arteries. The repeatability of the method was investigated by repeated, continuous infusions of angiotensin II and endothelin-1 seven...... arterial blood pressure by 49% and decreased TRBF by 12%, providing an increase in renal vascular resistance of 69%. Dynamic analysis showed autoregulation of renal blood flow in the frequency range ... of TRBF by aortic blood flow subtraction is a practical and reliable method that allows direct comparison of excretory function and renal blood flow from two kidneys. The method also allows direct comparison between TRBF and flow in the caudal aorta....

  5. FDM Analysis for Blood Flow through Stenosed Tapered Arteries

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2010-01-01

    Full Text Available Abstract A computational model is developed to analyze the unsteady flow of blood through stenosed tapered narrow arteries, treating blood as a two-fluid model with the suspension of all the erythrocytes in the core region as Herschel-Bulkley fluid and the plasma in the peripheral layer as Newtonian fluid. The finite difference method is employed to solve the resulting system of nonlinear partial differential equations. The effects of stenosis height, peripheral layer thickness, yield stress, viscosity ratio, angle of tapering and power law index on the velocity, wall shear stress, flow rate and the longitudinal impedance are analyzed. It is found that the velocity and flow rate increase with the increase of the peripheral layer thickness and decrease with the increase of the angle of tapering and depth of the stenosis. It is observed that the flow rate decreases nonlinearly with the increase of the viscosity ratio and yield stress. The estimates of the increase in the longitudinal impedance to flow are considerably lower for the two-fluid Herschel-Bulkley model compared with those of the single-fluid Herschel-Bulkley model. Hence, it is concluded that the presence of the peripheral layer helps in the functioning of the diseased arterial system.

  6. Pressure measurements in arterial feeders of brain arteriovenous malformations before and after endovascular embolization

    International Nuclear Information System (INIS)

    Henkes, H.; Gotwald, T.F.; Brew, S.; Kaemmerer, F.; Miloslavski, E.; Kuehne, D.

    2004-01-01

    Arteriovenous malformations (AVMs) are composed of abnormal arterial and venous vessels in the brain causing arteriovenous shunts of arterialized blood directly from pial arteries to draining veins. The hemodynamics of these lesions is not well-understood. Changes in blood flow and pressure are probably related to the natural history of AVMs and may also play a major role in AVM treatment. In this study intra-arterial pressure was measured in feeding arteries of AVMs using a microcatheter that had been placed for subsequent embolization treatment (201 measurements were performed in 95 patients before and after the embolization procedure). Results show a direct relationship between pressure changes and degree of embolization. Since pressure changes during the embolization procedure are relatively small, it seems unlikely that these changes are the direct cause of rupture and periprocedural bleedings. (orig.)

  7. Effects of preoperative aspirin and clopidogrel therapy on perioperative blood loss and blood transfusion requirements in patients undergoing off-pump coronary artery bypass graft surgery.

    Science.gov (United States)

    Shim, Jae Kwang; Choi, Yong Seon; Oh, Young Jun; Bang, Sou Ouk; Yoo, Kyung Jong; Kwak, Young Lan

    2007-07-01

    Preoperative exposure to clopidogrel and aspirin significantly increases postoperative bleeding in patients undergoing on-pump coronary artery bypass graft surgery. Off-pump coronary bypass grafting has been proposed as an alternative technique to attenuate postoperative bleeding associated with clopidogrel. This study aimed to determine the effects of aspirin and clopidogrel therapy on perioperative blood loss and blood transfusion requirements in off-pump coronary artery bypass grafting. One hundred six patients scheduled for off-pump coronary artery bypass grafting were divided into three groups: aspirin and clopidogrel discontinued more than 6 days before surgery (group 1, n = 35), aspirin and clopidogrel continued until 3 to 5 days before surgery (group 2, n = 51), and both medications continued within 2 days of surgery (group 3, n = 20). Thromboelastographic tracings were analyzed before induction of anesthesia. Routine coagulation profiles were measured before and after surgery. A cell salvage device was used during surgery and salvaged blood was reinfused. Chest tube drainage and blood transfusion requirement were recorded postoperatively. Patient characteristics, operative data, and thromboelastographic tracings were similar among the groups. There were significant decreases in hematocrit level and platelet count and prolongation in prothrombin time postoperatively in all groups without any intergroup differences. The amounts of perioperative blood loss and blood transfusion required were all similar among the groups. Preoperative clopidogrel and aspirin exposure even within 2 days of surgery does not increase perioperative blood loss and blood transfusion requirements in patients undergoing elective off-pump coronary artery bypass grafting.

  8. Intravenous digital subtraction angiography for the evaluation of renal artery blood flow following the removal of a neuroblastoma

    International Nuclear Information System (INIS)

    Yamagiwa, Iwao; Obata, Kazuya; Saito, Hiroyuki; Washio, Masahiko

    1994-01-01

    There have been several reports of acute renal failure following the resection of an abdominal neuroblastoma combined with ipsilateral nephrectomy as well as the atrophy or disappearance of an unresected kidney after tumor resection. Spasms or thrombosis of the renal artery during tumor excision are considered to be the major cause. Since 1989, intravenous digital subtraction angiography (IVDSA) has been used to evaluate the renal artery blood flow immediately following surgery in seven patients with abdominal neuroblastomas. IVDSA was performed using a central venous catheter inserted prior to surgery. In all seven patients, IVDSA provided clear images for the evaluation of renal artery blood flow. In one of the two patients whose kidneys briefly became cyanosed during tumor excision, IVDSA demonstrated an occlusion of the renal artery and prompt measures could be taken to reestablish the blood flow. No complications of IVDSA occurred in any of the seven patients. IVDSA using a central venous catheter was thus considered to be useful for evaluating the renal artery blood flow in patients with a suspected renal artery blood flow disturbance without any risk of complications, and this modality obviated the need for intraarterial angiography. (author)

  9. Automatic Blood Pressure Measurements During Exercise

    Science.gov (United States)

    Weaver, Charles S.

    1985-01-01

    Microprocessor circuits and a computer algorithm for automatically measuring blood pressure during ambulatory monitoring and exercise stress testing have been under development at SRI International. A system that records ECG, Korotkov sound, and arm cuff pressure for off-line calculation of blood pressure has been delivered to NASA, and an LSLE physiological monitoring system that performs the algorithm calculations in real-time is being constructed. The algorithm measures the time between the R-wave peaks and the corresponding Korotkov sound on-set (RK-interval). Since the curve of RK-interval versus cuff pressure during deflation is predictable and slowly varying, windows can be set around the curve to eliminate false Korotkov sound detections that result from noise. The slope of this curve, which will generally decrease during exercise, is the inverse of the systolic slope of the brachial artery pulse. In measurements taken during treadmill stress testing, the changes in slopes of subjects with coronary artery disease were markedly different from the changes in slopes of healthy subjects. Measurements of slope and O2 consumption were also made before and after ten days of bed rest during NASA/Ames Research Center bed rest studies. Typically, the maximum rate of O2 consumption during the post-bed rest test is less than the maximum rate during the pre-bed rest test. The post-bed rest slope changes differ from the pre-bed rest slope changes, and the differences are highly correlated with the drop in the maximum rate of O2 consumption. We speculate that the differences between pre- and post-bed rest slopes are due to a drop in heart contractility.

  10. Considerations for SphygmoCor radial artery pulse wave analysis: side selection and peripheral arterial blood pressure calibration.

    Science.gov (United States)

    Martin, Jeffrey S; Borges, Alexandra R; Christy, John B; Beck, Darren T

    2015-10-01

    Methods employed for pulse wave analysis (PWA) and peripheral blood pressure (PBP) calibration vary. The purpose of this study was to evaluate the agreement of SphygmoCor PWA parameters derived from radial artery tonometry when considering (1) timing (before vs. after tonometry) and side selection (ipsilateral vs. contralateral limb) for PBP calibration and (2) side selection for tonometry (left vs. right arm). In 34 subjects (aged 21.9 ± 2.3 years), bilateral radial artery tonometry was performed simultaneously on three instances. PBP assessment via oscillometric sphygmomanometry in the left arm only and both arms simultaneously occurred following the first and second instances of tonometry, respectively. Significant within arm differences in PWA parameters derived before and after PBP measurement were observed in the right arm only (for example, aortic systolic blood pressure, Δ=0.38 ± 0.64 mm Hg). Simultaneously captured bilateral PWA variables demonstrated significant between arm differences in 88% (14/16) and 56% (9/16) of outcome variables when calibrated to within arm and equivalent PBP, respectively. Moreover, the right arm consistently demonstrated lower values for clinical PWA variables (for example, augmentation index, bias=-2.79%). However, 26% (n=9) of participants presented with clinically significant differences (>10 mm Hg) in bilateral PBP and their exclusion from analysis abolished most between arm differences observed. SphygmoCor PWA in the right radial artery results in greater variability independent of the timing of PBP measurement and magnitude of calibration pressures in young subjects. Moreover, bilateral PBP measurement is imperative to identify subjects in whom a significant difference in bilateral PWA outcomes may exist.

  11. Comparison of arterial blood gas with continuous intra-arterial and transcutaneous PO2 sensors in adult critically ill patients.

    Science.gov (United States)

    Green, G E; Hassell, K T; Mahutte, C K

    1987-05-01

    We compared the partial pressure of oxygen directly via a continuous intra-arterial probe (PiaO2) and indirectly using a transcutaneous device (PtcO2) with simultaneously obtained arterial blood PaO2. The PiaO2 values were measured using a bipolar oxygen sensor placed through an 18-ga arterial catheter. The PtcO2 values were measured using a transcutaneous O2-CO2 sensor placed on the abdomen. Seven critically ill, hemodynamically stable, ventilator-dependent adult patients were studied. Measurements were obtained at varying concentrations (0.25 to 1.0) of inspired oxygen after a 10-min stabilization. A total of 78 simultaneous values were obtained; by linear regression: PiaO2 = 0.91 PaO2 + 1.39 (r = .98, standard errors of the estimate [SEE] = 18.6); PtcO2 = 0.39 PaO2 + 36.2 (r = .89, SEE = 14.1). To assess these instruments as trend monitors, we compared the changes in simultaneous PaO2, PiaO2, and PtcO2 values; by linear regression: delta PiaO2 = 0.90 delta PaO2 + 3.88 (r = .96, SEE = 27.7); delta PtcO2 = 0.43 delta PaO2 + 5.6 (r = .94, SEE = 15.2). We conclude that, although these instruments correlate highly with the PaO2, the SEE was substantial and therefore may limit their clinical reliability in adults. Any acute or clinically significant change in PiaO2 or PtcO2 should be confirmed with a blood gas PaO2.

  12. Elevated arterial blood pressure after superior cavo-pulmonary anastomosis is associated with elevated pulmonary artery pressure and cerebrovascular dysautoregulation.

    Science.gov (United States)

    Cabrera, Antonio G; Kibler, Kathleen K; Blaine Easley, R; Goldsworthy, Michelle; Shekerdemian, Lara S; Andropoulos, Dean B; Heinle, Jeffrey; Gottlieb, Erin A; Vu, Eric; Brady, Ken M

    2018-04-18

    BackgroundElevated arterial blood pressure (ABP) is common after superior bidirectional cavopulmonary anastomosis (BCPA). The effects of elevated ABP after BCPA on cerebrovascular hemodynamics are unknown. We sought to determine the relationship between elevated ABP and cerebrovascular autoregulation after BCPA.MethodsProspective, observational study on infants with single-ventricle physiology after BCPA surgery. Continuous recordings of mean ABP, mean cavopulmonary artery pressure (PAP), near-infrared spectroscopy measures of cerebral oximetry (regional cerebral oxygen saturation (rSO 2 )), and relative cerebral blood volume index were obtained from admission to extubation. Autoregulation was measured as hemoglobin volume index (HVx). Physiologic variables, including the HVx, were tested for variance across ABP.ResultsSixteen subjects were included in the study. Elevated ABP post-BCPA was associated with both, elevated PAP (PABP and alterations in rSO 2 . Using piecewise regression, the relationship of PAP to ABP demonstrated a breakpoint at 68 mm Hg (interquartile range (IQR) 62-70 mm Hg). Curve fit of HVx as a function of ABP identified optimal ABP supporting robust autoregulation at a median ABP of 55 mm Hg (IQR 51-64 mm Hg).ConclusionsElevated ABP post-BCPA is associated with cerebrovascular dysautoregulation, and elevated PAP. The effects, of prolonged dysautoregulation within this population, require further study.Pediatric Research advance online publication, 18 April 2018; doi:10.1038/pr.2018.31.

  13. Corrections of arterial input function for dynamic H215O PET to assess perfusion of pelvic tumours: arterial blood sampling versus image extraction

    International Nuclear Information System (INIS)

    Luedemann, L; Sreenivasa, G; Michel, R; Rosner, C; Plotkin, M; Felix, R; Wust, P; Amthauer, H

    2006-01-01

    Assessment of perfusion with 15 O-labelled water (H 2 15 O) requires measurement of the arterial input function (AIF). The arterial time activity curve (TAC) measured using the peripheral sampling scheme requires corrections for delay and dispersion. In this study, parametrizations with and without arterial spillover correction for fitting of the tissue curve are evaluated. Additionally, a completely noninvasive method for generation of the AIF from a dynamic positron emission tomography (PET) acquisition is applied to assess perfusion of pelvic tumours. This method uses a volume of interest (VOI) to extract the TAC from the femoral artery. The VOI TAC is corrected for spillover using a separate tissue TAC and for recovery by determining the recovery coefficient on a coregistered CT data set. The techniques were applied in five patients with pelvic tumours who underwent a total of 11 examinations. Delay and dispersion correction of the blood TAC without arterial spillover correction yielded in seven examinations solutions inconsistent with physiology. Correction of arterial spillover increased the fitting accuracy and yielded consistent results in all patients. Generation of an AIF from PET image data was investigated as an alternative to arterial blood sampling and was shown to have an intrinsic potential to determine the AIF noninvasively and reproducibly. The AIF extracted from a VOI in a dynamic PET scan was similar in shape to the blood AIF but yielded significantly higher tissue perfusion values (mean of 104.0 ± 52.0%) and lower partition coefficients (-31.6 ± 24.2%). The perfusion values and partition coefficients determined with the VOI technique have to be corrected in order to compare the results with those of studies using a blood AIF

  14. Changes in Hepatic Blood Flow During Transcatheter Arterial Infusion with Heated Saline in Hepatic VX2 Tumor

    International Nuclear Information System (INIS)

    Cao Wei; Li Jing; Wu Zhiqun; Zhou Changxi; Liu Xi; Wan Yi; Duan Yunyou

    2013-01-01

    Purpose. This study evaluates the influence of transcatheter arterial infusion with heated saline on hepatic arterial and portal venous blood flows to tumor and normal hepatic tissues in a rabbit VX2 tumor model. Methods. All animal experiments were approved by the institutional animal care and use committee. Twenty rabbits with VX2 liver tumors were divided into the following two groups: (a) the treated group (n = 10), which received a 60 mL transarterial injection of 60 °C saline via the hepatic artery; (b) the control group (n = 10), which received a 60 mL injection of 37 °C saline via the hepatic artery. Using ultrasonography, the blood flows in both the portal vein and hepatic artery were measured, and the changes in the hemodynamic indices were recorded before and immediately after the injection. The changes in the tumor and normal liver tissues of the two groups were histopathologically examined by hematoxylin and eosin staining after the injection. Results. After the transcatheter arterial heated infusion, there was a decrease in the hepatic arterial blood flow to the tumor tissue, a significant decrease in the hepatic artery mean velocity (P < 0.05), and a significant increase in the resistance index (P < 0.05). On hematoxylin and eosin staining, there were no obvious signs of tissue destruction in the normal liver tissue or the tumor tissue after heated perfusion, and coagulated blood plasma was observed in the cavities of intratumoral blood vessels in the treated group. Conclusions. The changes in tumor blood flow in the rabbit VX2 tumor model were presumably caused by microthrombi in the tumor vessels, and the portal vein likely mediated the heat loss in normal liver tissue during the transarterial heated infusion.

  15. Changes in Hepatic Blood Flow During Transcatheter Arterial Infusion with Heated Saline in Hepatic VX2 Tumor

    Energy Technology Data Exchange (ETDEWEB)

    Cao Wei, E-mail: cawe-001@163.com [Tangdu Hospital, The Fourth Military Medical University, Department of Interventional Radiology (China); Li Jing, E-mail: lijing02@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Burn and Plastic Surgery (China); Wu Zhiqun, E-mail: zhiqunwu@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Interventional Radiology (China); Zhou Changxi, E-mail: changxizhou@163.com [Chinese PLA General Hospital, Department of Respiratory Disease (China); Liu Xi, E-mail: xiliu@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Ultrasound Diagnostics (China); Wan Yi, E-mail: yiwan@163.com [The Fourth Military Medical University, Department of Health Statistics, Institute for Health Informatics (China); Duan Yunyou, E-mail: yunyouduan@fmmu.edu.cn [Tangdu Hospital, The Fourth Military Medical University, Department of Ultrasound Diagnostics (China)

    2013-06-15

    Purpose. This study evaluates the influence of transcatheter arterial infusion with heated saline on hepatic arterial and portal venous blood flows to tumor and normal hepatic tissues in a rabbit VX2 tumor model. Methods. All animal experiments were approved by the institutional animal care and use committee. Twenty rabbits with VX2 liver tumors were divided into the following two groups: (a) the treated group (n = 10), which received a 60 mL transarterial injection of 60 Degree-Sign C saline via the hepatic artery; (b) the control group (n = 10), which received a 60 mL injection of 37 Degree-Sign C saline via the hepatic artery. Using ultrasonography, the blood flows in both the portal vein and hepatic artery were measured, and the changes in the hemodynamic indices were recorded before and immediately after the injection. The changes in the tumor and normal liver tissues of the two groups were histopathologically examined by hematoxylin and eosin staining after the injection. Results. After the transcatheter arterial heated infusion, there was a decrease in the hepatic arterial blood flow to the tumor tissue, a significant decrease in the hepatic artery mean velocity (P < 0.05), and a significant increase in the resistance index (P < 0.05). On hematoxylin and eosin staining, there were no obvious signs of tissue destruction in the normal liver tissue or the tumor tissue after heated perfusion, and coagulated blood plasma was observed in the cavities of intratumoral blood vessels in the treated group. Conclusions. The changes in tumor blood flow in the rabbit VX2 tumor model were presumably caused by microthrombi in the tumor vessels, and the portal vein likely mediated the heat loss in normal liver tissue during the transarterial heated infusion.

  16. Arterial stiffness, cardiovagal baroreflex sensitivity and postural blood pressure changes in older adults: the Rotterdam Study

    NARCIS (Netherlands)

    Mattace-Raso, Francesco U. S.; van den Meiracker, Anton H.; Bos, Willem Jan; van der Cammen, Tischa J. M.; Westerhof, Berend E.; Elias-Smale, Suzette; Reneman, Robert S.; Hoeks, Arnold P. G.; Hofman, Albert; Witteman, Jacqueline C. M.

    2007-01-01

    Arterial stiffness may be involved in the impairment of the arterial baroreflex. In the present study the associations between arterial stiffness and cardiovagal baroreflex sensitivity (BRS) and between BRS and postural blood pressure (BP) changes were investigated within the framework of the

  17. Evaluation of blood flow in Allograft Renal Arteries anastomosed with two different techniques

    International Nuclear Information System (INIS)

    Zomorrodi, A.; Bohluli, A.; Tarzamany, M.K.

    2008-01-01

    Renal artery stenosis in renal transplantation (TRAS) is an avoidable short or long term surgical complication. The etiology is multifactorial, but faulty anastomosis is a major factor. In our transplant center, we evaluated the incidence of TRAS with the use of two different suturing techniques of the anastomosis site between allograft renal and renal and iliac arteries in two groups of renal transplant recipients, group A: 14 patients (6 males and 8 females with age 16 to 59 and mean age of 38 years) in whom allograft arteries were anastomosed with a continuous suture technique and group B: 14 patients (7 males and 7 females with age 32 to 61 and mean age of 46.6 years) in whom the allograft arteries were anastomosed with a combined suture technique (continuous and uninterrupted. Post transplantation, the velocity of blood flow in the renal and iliac arteries at the site of anastomosis was measured by color Doppler ultrasound. The ultrasonographer was blinded to the surgical technique in both study groups. The ratio of the maximum velocity of blood at the site of anastomosis to that in the iliac artery of less than 2.5 was considered as non-significant stenosis, while a ratio of more than 2.5 was considered significant stenosis. In group A there were 9 cases of non-significant stenosis in comparison to 3 cases in group B, while there were no cases of significant stenosis in group A in comparison to 3 cases in group B; the difference was not statistically significant. We conclude that there was no difference in the compared surgical techniques of anastomosis in our study groups. This suggests that other factors such as gentle handling of tissue, enough spatula, margin reversion and comparable diameter of the anastomosed vessels may be more important in the prevention of renal allograft stenosis than the type of suture technique. (author)

  18. Relationship between preoperative radial artery and postoperative arteriovenous fistula blood flow in hemodialysis patients.

    Science.gov (United States)

    Sato, Michiko; Io, Hiroaki; Tanimoto, Mitsuo; Shimizu, Yoshio; Fukui, Mitsumine; Hamada, Chieko; Horikoshi, Satoshi; Tomino, Yasuhiko

    2012-01-01

    It is recommended that arteriovenous fistula (AVF) blood flow should be more than 425 ml/min before cannulation. However, the relationship between preoperative radial artery flow (RAF) and postoperative AVF blood flow has still not been examined. Sixty-one patients with end-stage kidney disease (ESKD) were examined. They had an AVF prepared at Juntendo University Hospital from July 2006 through August 2007. Preoperative RAF and postoperative AVF blood flows were measured by ultrasonography. AVF blood flow gradually increased after the operation. AVF blood flow was significantly correlated with preoperative RAF. When preoperative RAF exceeded 21.4 ml/min, AVF blood flow rose to more than 425 ml/min. The postoperative AVF blood flow in the group with RAF of more than 20 ml/min was significantly higher than that in those with less than 20 ml/min. Preoperative RAF of less than 20 ml/min had a significantly high risk of primary AVF failure within 8 months compared with that of more than 20 ml/min. It appears that measurement of RAF by ultrasonography is useful for estimating AVF blood flow postoperatively and can predict the risk of complications in ESKD patients.

  19. The artery blood supply variant of the upper limb

    Science.gov (United States)

    MASLARSKI, IVAN

    2015-01-01

    Variations of arterial patterns in the upper limb have represented the most common subject of vascular anatomy. Different types of artery branching pattern of the upper limb are very important for orthopedists in angiographic and microvascular surgical practice. The brachial artery (BA) is the most important vessel in the normal vascular anatomy of the upper limb. The classical pattern of the palmar hand region distribution shows the superficial palmar arch. Normally this arch is formed by the superficial branch of the ulnar artery and completed on the lateral side by one of these arteries: the superficial palmar branch of the radial artery, the princeps pollicis artery, the superficial palmar branch of the radial artery or the median artery. After the routine dissection of the right upper limb of an adult male cadaver, we found a very rare variant of the superficial arch artery – a division in a higher level brachial artery. We found this division at 10.4 cm from the beginning of the brachial artery. This superficial brachial artery became a radial artery and was not involved in the formation of the palm arch. In the forearm region, the artery variant was present with the median artery and the ulnar artery, which form the superficial palm arch. PMID:26733754

  20. Blood vessel classification into arteries and veins in retinal images

    Science.gov (United States)

    Kondermann, Claudia; Kondermann, Daniel; Yan, Michelle

    2007-03-01

    The prevalence of diabetes is expected to increase dramatically in coming years; already today it accounts for a major proportion of the health care budget in many countries. Diabetic Retinopathy (DR), a micro vascular complication very often seen in diabetes patients, is the most common cause of visual loss in working age population of developed countries today. Since the possibility of slowing or even stopping the progress of this disease depends on the early detection of DR, an automatic analysis of fundus images would be of great help to the ophthalmologist due to the small size of the symptoms and the large number of patients. An important symptom for DR are abnormally wide veins leading to an unusually low ratio of the average diameter of arteries to veins (AVR). There are also other diseases like high blood pressure or diseases of the pancreas with one symptom being an abnormal AVR value. To determine it, a classification of vessels as arteries or veins is indispensable. As to our knowledge despite the importance there have only been two approaches to vessel classification yet. Therefore we propose an improved method. We compare two feature extraction methods and two classification methods based on support vector machines and neural networks. Given a hand-segmentation of vessels our approach achieves 95.32% correctly classified vessel pixels. This value decreases by 10% on average, if the result of a segmentation algorithm is used as basis for the classification.

  1. Experimental investigation of the flow of a blood analogue fluid in a replica of a bifurcated small artery.

    Science.gov (United States)

    Anastasiou, A D; Spyrogianni, A S; Koskinas, K C; Giannoglou, G D; Paras, S V

    2012-03-01

    The scope of this work is to study the pulsatile flow of a blood mimicking fluid in a micro channel that simulates a bifurcated small artery, in which the Fahraeus-Lindqvist effect is insignificant. An aqueous glycerol solution with small amounts of xanthan gum was used for simulating viscoelastic properties of blood and in vivo flow conditions were reproduced. Local flow velocities were measured using micro Particle Image Velocimetry (μ-PIV). From the measured velocity distributions, the wall shear stress (WSS) and its variation during a pulse were estimated. The Reynolds numbers employed are relatively low, i.e. similar to those prevailing during blood flow in small arteries. Experiments both with a Newtonian and a non-Newtonian fluid (having asymptotic viscosity equal to the viscosity of the Newtonian one) proved that the common assumption that blood behaves as a Newtonian fluid is not valid for blood flow in small arteries. It was also shown that the outer wall of the bifurcation, which is exposed to a lower WSS, is more predisposed to atherosclerotic plaque formation. Moreover, this region in small vessels is shorter than the one in large arteries, as the developed secondary flow decays faster. Finally, the WSS values in small arteries were found to be lower than those in large ones. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  2. Functional assessment of the hepatic arterial blood flow by pharmacoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Stellamor, K; Hruby, W; Peschl, L

    1981-12-01

    By means of celiacography it was possible to demonstrate that parenteral medication with parathormone creates a selective dilatation of the liver vessels in man, provided that they are dilatable. This hemodynamic hormone effect could not be traced in the other mesenteric vessels. The increase of portal hypertension resulting from cirrhosis leads to a loss of the dilating ability of liver vessels. This regressive reaction is well demonstrated on the parathormone-celiacogram. Thus a functional assessment of the hepatic blood flow is possible. The extent of the dilatability of the liver artery seems to be of great importance for the prognosis and indication of the porto-systemic shunt-operation. Moreover we could show that an increase in the liver perfusion demonstrates pathologic liver processes in a better way.

  3. Evaluation and investigation of regional cerebral blood flow by 1 point arterial blood collection method using 99mTc-ECD. Intravenous injection for 4 minutes with constant speed

    International Nuclear Information System (INIS)

    Itoh, Takeo; Shibata, Kazuhiro; Sudoh, Hideaki; Tanaka, Masato; Itoh, Kenjiro; Ueno, Yasushi

    1998-01-01

    Regional cerebral blood flow (rCBF) was measured using a 99m Tc-ECD through the 4-min constant intravenous infusion/one point arterial blood sampling method, proposed by Nakagawara et al. of Nakamura Memorial Hospital, and 133Xenon ( 133 Xe)-SPECT was performed on the same subjects to investigate the reproducibility of this method. We also determined whether cerebral blood flow (CBF) could be measured on the day of blood sampling through dilution of the obtained blood because it was difficult to measure the radioactivity in the blood on the day of blood sampling by this method. More, we investigated fixation of an octanol extraction rate and the substitution of venous blood for arterial blood in this method. The results revealed that CBF measured by this method with a 99m Tc-ECD were closely correlated to those measured by 133 Xe-SPECT, indicating the reliability as a method of measuring CBF. rCBF could be measured on the day of blood sampling through appropriate dilution of the obtained arterial blood. Octanol extraction rates were almost constant, indicating possible omission of cumbersome extraction procedure by fixation. However, the substitution of venous blood for arterial blood showed no correlation under the study system examined. (author)

  4. Choice of marker for assessment of RV dysfunction in acute pulmonary embolism : NT-proBNP, pulmonary artery systolic pressure, mean arterial pressure, or blood pressure index.

    Science.gov (United States)

    Ates, H; Ates, I; Kundi, H; Yilmaz, F M

    2017-12-01

    We aimed to examine the value of NT-proBNP, pulmonary artery systolic pressure (PASP), blood pressure index (BPI), and mean arterial pressure (MAP) in the determination of right ventricular dysfunction (RVD) in patients with acute pulmonary embolism (APE). A total of 547 patients diagnosed with APE were included in the study. Demographic characteristics and comorbid conditions of patients were recorded in patient files. For blood pressure measurement, a calibrated digital blood pressure monitor was used at regular intervals. Blood samples were taken from patients at the time of admission for hemogram, biochemical, and hemostasis blood tests. Echocardiography was performed on all patients to detect RVD and evaluate pulmonary artery pressure. PASP (p blood pressure (p blood cell (p AUC ± SE = 0.975 ± 0.006; p < 0.001) was found to be the best predictor of RVD with a higher sensitivity (92.8%) and specificity (100%). We found that BPI had a better diagnostic discrimination for RVD compared with PASP and NT-proBNP.

  5. Measurement of organ blood flow using tritiated water. II. Uterine blood flow in conscious pregnant ewes

    International Nuclear Information System (INIS)

    Brown, B.W.; Oddy, V.H.; Jones, A.W.

    1982-01-01

    Total uterine blood flow was measured with a tritiated water (TOH) diffusion method and with radioactive microspheres in six, conscious, pregnant ewes. With continuous infusion of TOH, equilibrium between the TOH concentration in utero-ovarian venous blood and arterial blood was attained within 50 min of the start of the infusion. The concentration of TOH in uterine and foetal tissue and in foetal blood water was the same as that in uterine venous water by 40 min; at this time, the concentration of TOH in the water of amniotic and allantoic fluids was 96% of that in uterine venous blood water. Estimates of total uterine blood flow obtained using TOH were highly correlated with those obtained with microspheres and the corresponding mean flow values obtained with the two techniques did not significantly differ. The percentage of the total uterine blood flow passing through arteriovenous anastomoses ranged from 1.4 to 3.3%

  6. Cantilever arrayed blood pressure sensor for arterial applanation tonometry.

    Science.gov (United States)

    Lee, Byeungleul; Jeong, Jinwoo; Kim, Jinseok; Kim, Bonghwan; Chun, Kukjin

    2014-03-01

    The authors developed a cantilever-arrayed blood pressure sensor array fabricated by (111) silicon bulk-micromachining for the non-invasive and continuous measurement of blood pressure. The blood pressure sensor measures the blood pressure based on the change in the resistance of the piezoresistor on a 5-microm-thick-arrayed perforated membrane and 20-microm-thick metal pads. The length and the width of the unit membrane are 210 and 310 microm, respectively. The width of the insensible zone between the adjacent units is only 10 microm. The resistance change over contact force was measured to verify the performance. The good linearity of the result confirmed that the polydimethylsiloxane package transfers the forces appropriately. The measured sensitivity was about 4.5%/N. The maximum measurement range and the resolution of the fabricated blood pressure sensor were greater than 900 mmHg (= 120 kPa) and less than 1 mmHg (= 133.3 Pa), respectively.

  7. The relationship between fasting blood glucose variability and coronary artery collateral formation in type 2 diabetes patients with coronary artery disease.

    Science.gov (United States)

    Cheng, Gang; Mahmoudi, Hilda; Chokshi, Binna; Fernandez, Marlena; Kazemi, Vahid; Lamaa, Nader

    2017-09-01

    Coronary collaterals are an alternative source of blood supply to ischemic myocardium. Well-developed coronary collateral arteries in patients with coronary artery disease (CAD) limit the size of acute myocardial infarction and improves survival. The aim of this study was to investigate the relationship between glycemic variability and coronary collateral formation in patients with type 2 diabetes mellitus and CAD. Consecutive patients undergoing percutaneous coronary intervention or coronary artery bypass grafting procedures were studied. Multivariate logistic regression models were used to examine the association between coronary artery collateral formation graded by Rentrope classification and glycemic variability, measured by coefficient variation of fasting blood glucose. In our study, we retrospectively enrolled 300 patients, of whom 239 were diabetic (age: 70.1±11.9, 56% men) and 61 were nondiabetic (age: 71.5±11.5, 72% men). Diabetic patients were further stratified as follows: those with poor coronary collateral artery development (n=171, age: 69.7±12.4, 55% men) and those with good coronary collateral artery development (n=68, age 71.1±10.8, 59% men) according to the Rentrope classification. Our findings did not show association between glycemic variability and coronary collateral vessels development after controlling for potential confounders (odds ratio: 2.51; 95% confidence interval: 0.57-11.03; P=0.22). The culprit lesion (≥75% stenosis) in the left anterior descending artery and the right coronary artery was more frequent in the good collateral group compared with the poor collateral group (66 vs. 50%, P=0.02; 63 vs. 45%, P=0.01 respectively). Glycemic variability is not associated with coronary collateral artery formation in patients with type 2 diabetes mellitus and CAD.

  8. Prediction of blood pressure and blood flow in stenosed renal arteries using CFD

    Science.gov (United States)

    Jhunjhunwala, Pooja; Padole, P. M.; Thombre, S. B.; Sane, Atul

    2018-04-01

    In the present work an attempt is made to develop a diagnostive tool for renal artery stenosis (RAS) which is inexpensive and in-vitro. To analyse the effects of increase in the degree of severity of stenosis on hypertension and blood flow, haemodynamic parameters are studied by performing numerical simulations. A total of 16 stenosed models with varying degree of stenosis severity from 0-97.11% are assessed numerically. Blood is modelled as a shear-thinning, non-Newtonian fluid using the Carreau model. Computational Fluid Dynamics (CFD) analysis is carried out to compute the values of flow parameters like maximum velocity and maximum pressure attained by blood due to stenosis under pulsatile flow. These values are further used to compute the increase in blood pressure and decrease in available blood flow to kidney. The computed available blood flow and secondary hypertension for varying extent of stenosis are mapped by curve fitting technique using MATLAB and a mathematical model is developed. Based on these mathematical models, a quantification tool is developed for tentative prediction of probable availability of blood flow to the kidney and severity of stenosis if secondary hypertension is known.

  9. Determining the Arterial Blood Pressure of People Living in Yesilyurt Local Healthcare Office

    Directory of Open Access Journals (Sweden)

    Feyza Dereli

    2009-02-01

    Full Text Available AIM: Whereas the prevalance of arterial blood pressure which was a chronical health problem was 20%-25% among 30 year-old people, them showing an increase in aging, the percentage went as high as 50% in 60’s and later ages. What was that worrisome was that despite the high prevalance, only half of these received treathment. This is study was descriptively and cross-sectionally planned to determine whether the people asking their tensions to be measured in and around the Yesilyurt local healthcare office region. METHODS: The environment of the research consisted of 1400 people over 35 age and registered Yesilyurt Local healthcare Office and the whole of the environment were included in this sample. The study was conducted over 340 voluntaries. The data was collected by a questionnaire of 14 questions containing socio-demografic features and by measuring the arterial blood pressure, height and weight of the individuals. In the evaluation of the data, chi-square test was used and the level of significantly was accepted as 0.05. RESULTS: In this study, the rate of high sistolic blood pressure was found to be 21.47% and the rate of high diastolic blood pressure to be 8.23%. It was determined that age and body mass index varrieties were effective on sistolic hipertension. It was also found that in their behaviors of the use of hypertensive medicine, of regular arterial pressure controls and of having the hypertesion diagnosis significant differnces varied statistically on both sistolic and diastolic blood pressure people having. CONCLUSION: In order to improve the health, informative information abouth hypertension was provided for the participants for too days consisting of 4 sessions. [TAF Prev Med Bull 2009; 8(1.000: 53-58

  10. The association of ABO blood groups with extent of coronary atherosclerosis in Croatian patients suffering from chronic coronary artery disease.

    Science.gov (United States)

    Karabuva, Svjetlana; Carević, Vedran; Radić, Mislav; Fabijanić, Damir

    2013-01-01

    The aim of study was to: 1) examine the relationship between ABO blood groups and extent of coronary atherosclerosis in patients with chronic coronary artery disease (CAD), 2) compare ABO blood groups distribution in CAD patients and general population, 3) examine possible differences in traditional risk factors frequency in CAD patients with different ABO blood groups. In the 646 chronic CAD patients (72.4% males) coronary angiograms were scored by quantitative assessment using multiple angiographic scoring system, Traditional risk factors were self reported or measured by standard methods. ABO blood distribution of patients was compared with group of 651 healthy blood donors (74.6% males). Among all ABO blood group patients there was no significant difference between the extent of coronary atherosclerosis with regard to all the three scoring systems: number of affected coronary arteries (P = 0.857), Gensini score (P = 0.818), and number of segments narrowed > 50% (P = 0.781). There was no significant difference in ABO blood group distribution between CAD patients and healthy blood donors. Among CAD patients, men with blood group AB were significantly younger than their pairs with non-AB blood groups (P = 0.008). Among CAD patients with AB blood group, males groups (P = 0.003). No association between ABO blood groups and the extent of coronary atherosclerosis in Croatian CAD patients is observed. Observation that AB blood group might possibly identify Croatian males at risk to develop the premature CAD has to be tested in larger cohort of patients.

  11. The Effects of Acutely Administered 3,4-Methylenedioxymethamphetamine on Spontaneous Brain Function in Healthy Volunteers Measured with Arterial Spin Labeling and Blood Oxygen Level–Dependent Resting State Functional Connectivity

    Science.gov (United States)

    Carhart-Harris, Robin L.; Murphy, Kevin; Leech, Robert; Erritzoe, David; Wall, Matthew B.; Ferguson, Bart; Williams, Luke T.J.; Roseman, Leor; Brugger, Stefan; De Meer, Ineke; Tanner, Mark; Tyacke, Robin; Wolff, Kim; Sethi, Ajun; Bloomfield, Michael A.P.; Williams, Tim M.; Bolstridge, Mark; Stewart, Lorna; Morgan, Celia; Newbould, Rexford D.; Feilding, Amanda; Curran, H. Val; Nutt, David J.

    2015-01-01

    Background The compound 3,4-methylenedioxymethamphetamine (MDMA) is a potent monoamine releaser that produces an acute euphoria in most individuals. Methods In a double-blind, placebo-controlled, balanced-order study, MDMA was orally administered to 25 physically and mentally healthy individuals. Arterial spin labeling and seed-based resting state functional connectivity (RSFC) were used to produce spatial maps displaying changes in cerebral blood flow (CBF) and RSFC after MDMA administration. Participants underwent two arterial spin labeling and two blood oxygen level–dependent scans in a 90-minute scan session; MDMA and placebo study days were separated by 1 week. Results Marked increases in positive mood were produced by MDMA. Decreased CBF only was observed after MDMA, and this was localized to the right medial temporal lobe (MTL), thalamus, inferior visual cortex, and the somatosensory cortex. Decreased CBF in the right amygdala and hippocampus correlated with ratings of the intensity of global subjective effects of MDMA. The RSFC results complemented the CBF results, with decreases in RSFC between midline cortical regions, the medial prefrontal cortex, and MTL regions, and increases between the amygdala and hippocampus. There were trend-level correlations between these effects and ratings of intense and positive subjective effects. Conclusions The MTLs appear to be specifically implicated in the mechanism of action of MDMA, but further work is required to elucidate how the drug’s characteristic subjective effects arise from its modulation of spontaneous brain activity. PMID:24495461

  12. The Effects of Acutely Administered 3,4-Methylenedioxymethamphetamine on Spontaneous Brain Function in Healthy Volunteers Measured with Arterial Spin Labeling and Blood Oxygen Level-Dependent Resting State Functional Connectivity.

    Science.gov (United States)

    Carhart-Harris, Robin L; Murphy, Kevin; Leech, Robert; Erritzoe, David; Wall, Matthew B; Ferguson, Bart; Williams, Luke T J; Roseman, Leor; Brugger, Stefan; De Meer, Ineke; Tanner, Mark; Tyacke, Robin; Wolff, Kim; Sethi, Ajun; Bloomfield, Michael A P; Williams, Tim M; Bolstridge, Mark; Stewart, Lorna; Morgan, Celia; Newbould, Rexford D; Feilding, Amanda; Curran, H Val; Nutt, David J

    2015-10-15

    The compound 3,4-methylenedioxymethamphetamine (MDMA) is a potent monoamine releaser that produces an acute euphoria in most individuals. In a double-blind, placebo-controlled, balanced-order study, MDMA was orally administered to 25 physically and mentally healthy individuals. Arterial spin labeling and seed-based resting state functional connectivity (RSFC) were used to produce spatial maps displaying changes in cerebral blood flow (CBF) and RSFC after MDMA administration. Participants underwent two arterial spin labeling and two blood oxygen level-dependent scans in a 90-minute scan session; MDMA and placebo study days were separated by 1 week. Marked increases in positive mood were produced by MDMA. Decreased CBF only was observed after MDMA, and this was localized to the right medial temporal lobe (MTL), thalamus, inferior visual cortex, and the somatosensory cortex. Decreased CBF in the right amygdala and hippocampus correlated with ratings of the intensity of global subjective effects of MDMA. The RSFC results complemented the CBF results, with decreases in RSFC between midline cortical regions, the medial prefrontal cortex, and MTL regions, and increases between the amygdala and hippocampus. There were trend-level correlations between these effects and ratings of intense and positive subjective effects. The MTLs appear to be specifically implicated in the mechanism of action of MDMA, but further work is required to elucidate how the drug's characteristic subjective effects arise from its modulation of spontaneous brain activity. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  13. Blood-conservation techniques for coronary-artery bypass surgery at a private hospital.

    Science.gov (United States)

    Davies, M J; Picken, J; Buxton, B F; Fuller, J A

    1988-11-21

    The utilization of homologous blood and blood products was recorded in 100 consecutive patients who underwent primary coronary-artery bypass surgery. Nine patients underwent saphenous-vein grafts only, 55 patients underwent a single internal-mammary-artery graft that was supplemented by vein grafts and 36 patients underwent bilateral internal-mammary-artery grafts and vein grafts. All patients underwent normovolaemic haemodilution, and autologous blood was collected before bypass surgery. Residual blood was collected from the cardiopulmonary bypass machine and was washed and concentrated in a cell processor, and blood also was scavenged postoperatively from the mediastinal drainage tubes as methods to conserve blood. The mean (+/- SD) utilization of homologous blood was 1.3 +/- 1.5 units with 0.2 +/- 0.7 units of fresh-frozen plasma being used, and 0.8 +/- 2.1 units of platelets being used. The utilization of homologous blood was not different among the three different methods of coronary-artery bypass surgery, but patients who underwent bilateral internal-mammary-artery grafts suffered a greater postoperative loss of blood than did those patients who underwent saphenous-vein grafts or single internal-mammary-artery grafts. A comparison of patients who were taking aspirin or a non-steroidal anti-inflammatory drug preoperatively with those patients who were not showed no difference in the utilization of homologous blood but a statistically-significant difference was found in the loss of blood postoperatively.

  14. Comparison of ambulatory blood pressure monitoring and office blood pressure measurements in obese children and adolescents.

    Science.gov (United States)

    Renda, Rahime

    2018-04-01

    Obesity in adults has been related to hypertension and abnormal nocturnal dipping of blood pressure, which are associated with poor cardiovascular and renal outcomes. Here, we aimed to resolve the relationship between the degree of obesity, the severity of hypertension and dipping status on ambulatory blood pressure in obese children. A total 72 patients with primary obesity aged 7 to 18 years (mean: 13.48 ± 3.25) were selected. Patients were divided into three groups based on body mass index (BMİ) Z-score. Diagnosis and staging of ambulatory hypertension based on 24-h blood pressure measurements, obtained from ambulatory blood pressure monitoring. Based on our ambulatory blood pressure data, 35 patients (48.6%) had hypertension, 7 (20%) had ambulatory prehypertension, 21 (60%) had hypertension, and 7 patients (20%) had severe ambulatory hypertension. There was a significant relationship between severity of hypertension and the degree of obesity (p lood pressure results and loads were similar between groups. Diastolic and mean arterial blood pressure levels during the night, diastolic blood pressure loads, and heart rate during the day were significantly higher in Group 3 (p lood pressure at night, mean arterial pressure at night, diastolic blood pressure loads and heart rate at day. Increase in BMI Z-score does not a significant impact on daytime blood pressure and nocturnal dipping status.

  15. [Influence of Sympathetic Denervation of the Renal Artery on the Level of Arterial Blood Pressure, Cerebral Blood Flow and Cognitive Function In Patients With Resistant Arterial Hypertension].

    Science.gov (United States)

    Efimova, Y N; Lichikaki, A V; Lishmanov, B Y

    2017-07-01

    To study the effect of radiofrequency ablation of renal arteries on regional cerebral blood flow and cognitive function in patients with resistant arterial hypertension (AH). Transcatheter renal denervation (TRD) was performed in 17 patients with resistant AH. Examination before and after TRD included SPECT with mTc-HMPAO, 24-hours blood pressure (BP) monitoring, and comprehensive neuropsychological testing. Fifteen patients without angiographic signs of carotid atherosclerosis, coronary artery disease and AH, neurological and psychiatric disorders were investigated as control group. Compared with control group patients with AH had decreases of regional cerebral blood flow (rCBF) in right (by 13.5%, p=0.00002) and left (by 15.5%, p=0.0006) inferior frontal lobes, in right temporal brain region (by 11.5%, p=0.008); in right and left occipital lobes (by 8.2%, p=0.04). In 6 months after TRD we observed significant improvement of cognitive function, parameters of 24-hour BP monitoring, and rCBF. We also noted definite close interdependence between changes of rCBF, indices of 24-hours BP monitoring, and dynamics of cognitive function. Improvement of long-term verbal memory correlated with increases of rCBF in left superior frontal and right occipital regions while dynamics of mentation and attention correlated positively with augmentation of rCBF in right posterior parietal region. Changes of perfusion in inferior parts of left frontal lobe and in right occipital region correlated with dynamics of index of diurnal diastolic hypertension time (R2=0.64, p=0.001, and R2=0.60, p=0.03, respectively). Our results suggest, that in patients with resistant AH positive effect of TRD on levels of 24-hour mean BP as well as on indices of BP load leads to in augmentation of rCBF and improvement of cognitive function.

  16. Functional dilatation and medial remodeling of the renal artery in response to chronic increased blood flow.

    Science.gov (United States)

    Roan, Jun-Neng; Yeh, Chin-Yi; Chiu, Wen-Cheng; Lee, Chou-Hwei; Chang, Shih-Wei; Jiangshieh, Ya-Fen; Tsai, Yu-Chuan; Lam, Chen-Fuh

    2011-01-01

    Renal blood flow (RBF) is tightly regulated by several intrinsic pathways in maintaining optimal kidney blood supply. Using a rat model of aortocaval (AC) fistula, we investigated remodeling of the renal artery following prolonged increased blood flow. An AC fistula was created in the infrarenal aorta of anesthetized rats, and changes of blood flow in the renal artery were assessed using an ultrasonic flow probe. Morphological changes and expression of endothelial nitric oxide synthase and matrix metalloproteinase-2 in the remodeled renal artery were analyzed. Blood flow in the renal artery increased immediately after creation of AC fistula, but normal RBF was restored 8 weeks later. The renal artery dilated significantly 8 weeks after operation. Expression of endothelial nitric oxide synthase and matrix metalloproteinase-2 was upregulated shortly after blood flow increase, and returned to baseline levels after 3 weeks. Histological sections showed luminal dilatation with medial thickening and endothelial cell-to-smooth muscle cell attachments in the remodeled renal artery. Increased RBF was accommodated by functional dilatation and remodeling in the medial layer of the renal artery in order to restore normal blood flow. Our results provide important mechanistic insight into the intrinsic regulation of the renal artery in response to increased RBF. Copyright © 2011 S. Karger AG, Basel.

  17. Prognostic value of renal fractional flow reserve in blood pressure response after renal artery stenting (PREFER study).

    Science.gov (United States)

    Kądziela, Jacek; Januszewicz, Andrzej; Prejbisz, Aleksander; Michałowska, Ilona; Januszewicz, Magdalena; Florczak, Elżbieta; Kalińczuk, Łukasz; Norwa-Otto, Bożena; Warchoł, Ewa; Witkowski, Adam

    2013-01-01

    The aim of our study was to determine a potential relationship between resting translesional pressures ratio (Pd/Pa ratio), renal fractional flow reserve (rFFR) and blood pressure response after renal artery stenting. Thirty five hypertensive patients (49% males, mean age 64 years) with at least 60% stenosis in angiography, underwent renal artery stenting. Translesional systolic pressure gradient (TSPG), Pd/Pa ratio (the ratio of mean distal to lesion and mean proximal pressures) and hyperemic rFFR - after intrarenal administration of papaverine - were measured before stent implantation. Ambulatory blood pressure measurements (ABPM) were recorded before the procedure and after 6 months. The ABPM results were presented as blood pressure changes in subgroups of patients with normal (≥ 0.9) vs. abnormal (renal artery stenting. Median changes of 24-h systolic/diastolic blood pressure were comparable in patients with abnormal vs. normal Pd/Pa ratio (-4/-3 vs. 0/2 mm Hg; p = NS) and with abnormal vs. normal rFFR (-2/-1 vs. -2/-0.5 mm Hg, respectively). Physiological assessment of renal artery stenosis using Pd/Pa ratio and papaverine- induced renal fractional fl ow reserve did not predict hypertension response after renal artery stenting.

  18. A prospective study of glomerular filtration rate and arterial blood pressure in insulin-dependent diabetics with diabetic nephropathy

    DEFF Research Database (Denmark)

    Parving, H H; Smidt, U M; Friisberg, B

    1981-01-01

    Glomerular filtration rate (GFR, single bolus 51Cr-EDTA technique), serum creatinine, proteinuria and arterial blood pressure have been measured prospectively in 14 young onset insulin-dependent diabetics selected by of persistent proteinuria (greater than 0.5 g/day) secondary to diabetic...... in arterial blood pressure to a hypertensive level is an early feature of diabetic nephropathy in young insulin-dependent diabetics....... and 112/mumol/l (NS), proteinuria increased from 1.8 to 3.3 g/day (p less than 0.001) and arterial blood pressure rose from 132/88 to 153/101 mmHg (p less than 0.001). Glomerular filtration rate decreased linearly with time (slope = -0.75, r = 0.99, p less than 0.001) by a mean of 0.75 ml/min/month (range...

  19. Doppler velocity measurements from large and small arteries of mice

    Science.gov (United States)

    Reddy, Anilkumar K.; Madala, Sridhar; Entman, Mark L.; Michael, Lloyd H.; Taffet, George E.

    2011-01-01

    With the growth of genetic engineering, mice have become increasingly common as models of human diseases, and this has stimulated the development of techniques to assess the murine cardiovascular system. Our group has developed nonimaging and dedicated Doppler techniques for measuring blood velocity in the large and small peripheral arteries of anesthetized mice. We translated technology originally designed for human vessels for use in smaller mouse vessels at higher heart rates by using higher ultrasonic frequencies, smaller transducers, and higher-speed signal processing. With these methods one can measure cardiac filling and ejection velocities, velocity pulse arrival times for determining pulse wave velocity, peripheral blood velocity and vessel wall motion waveforms, jet velocities for the calculation of the pressure drop across stenoses, and left main coronary velocity for the estimation of coronary flow reserve. These noninvasive methods are convenient and easy to apply, but care must be taken in interpreting measurements due to Doppler sample volume size and angle of incidence. Doppler methods have been used to characterize and evaluate numerous cardiovascular phenotypes in mice and have been particularly useful in evaluating the cardiac and vascular remodeling that occur following transverse aortic constriction. Although duplex ultrasonic echo-Doppler instruments are being applied to mice, dedicated Doppler systems are more suitable for some applications. The magnitudes and waveforms of blood velocities from both cardiac and peripheral sites are similar in mice and humans, such that much of what is learned using Doppler technology in mice may be translated back to humans. PMID:21572013

  20. Effect of volume expansion on systemic hemodynamics and central and arterial blood volume in cirrhosis

    DEFF Research Database (Denmark)

    Møller, S; Bendtsen, F; Henriksen, Jens Henrik Sahl

    1995-01-01

    , and arterial pressure were determined before and during a volume expansion induced by infusion of a hyperosmotic galactose solution. RESULTS: During volume expansion, the central and arterial blood volume increased significantly in patients with class A and controls, whereas no significant change was found...... in patients with either class B or class C. Conversely, the noncentral blood volume increased in patients with class B and C. In both patients and controls, the cardiac output increased and the systemic vascular resistance decreased, whereas the mean arterial blood pressure did not change significantly......BACKGROUND & AIMS: Systemic vasodilatation in cirrhosis may lead to hemodynamic alterations with reduced effective blood volume and decreased arterial blood pressure. This study investigates the response of acute volume expansion on hemodynamics and regional blood volumes in patients with cirrhosis...

  1. Straight versus tortuous retinal arteries in relation to blood pressure and genetics

    DEFF Research Database (Denmark)

    Taarnhøj, N C B B; Munch, I C; Sander, B

    2008-01-01

    dizygotic same-sex healthy twin pairs, aged 20 to 46 years, who were characterised by determination of retinal vessel diameters, arterial blood pressure, blood glucose, body mass index, smoking habits and retinal arterial tortuosity, using a three-level grading scale (straight, wavy, tortuous). Heritability......BACKGROUND/AIMS: To assess the relative influence of genetic and environmental factors on retinal arterial tortuosity and the association between tortuosity and various health indices in healthy young to middle-aged persons. METHODS: This cross-sectional study included 57 monozygotic and 52...... accounting for the remaining 18% (CI(95 )8, 36%). Increasing values of mean arterial blood pressure and body mass index were both associated with decreasing levels of retinal arterial tortuosity. CONCLUSION: There was a large variation in tortuosity of retinal arteries in these healthy subjects...

  2. Clinical study of color Doppler sonography in Graves' disease blood flow changes after thyroid arteries embolization

    International Nuclear Information System (INIS)

    Zhuang Wenquan; Li Weiduo; Yang Jianyong; Chen Wei; Huang Yonghui; Guo Wenbo; Li Jiaping

    2003-01-01

    Objective: To study the color doppler image characteristics of thyroid arteries pre- and post-interventional procedure and to assess the clinical efficacy in Gnaves' disease. Methods: 11 from 31 patients diagnosed as Graves' disease undertaken thyroid arteries embolization, were analyzed. Color Doppler sonography was applied to monitor the pre-and post- procedure thyroid size and diameters of thyroid arteries. Power Doppler was used to detect the Vmax, Vmin, RI and blood flow. Results: After thyroid arteries embolization, the size and vascularity of thyroids were reduced. The thyroid arteries showed shrinkage and stoppage blood flow at the embolized site. The changes of RI, blood parameters of Vmax, Vmin and diameters of the thyroid arteries pre- and post-procedure turned out to be statistically significant for clinical restriction. Conclusion: The color Doppler sonography plays an important role for preoperative diagnosis and predicting the prognosis

  3. Automated Office Blood Pressure Measurement.

    Science.gov (United States)

    Myers, Martin G

    2018-04-01

    Manual blood pressure (BP) recorded in routine clinical practice is relatively inaccurate and associated with higher readings compared to BP measured in research studies in accordance with standardized measurement guidelines. The increase in routine office BP is the result of several factors, especially the presence of office staff, which tends to make patients nervous and also allows for conversation to occur. With the disappearance of the mercury sphygmomanometer because of environmental concerns, there is greater use of oscillometric BP recorders, both in the office setting and elsewhere. Although oscillometric devices may reduce some aspects of observer BP measurement error in the clinical setting, they are still associated with higher BP readings, known as white coat hypertension (for diagnosis) or white coat effect (with treated hypertension). Now that fully automated sphygmomanometers are available which are capable of recording several readings with the patient resting quietly, there is no longer any need to have office staff present when BP is being recorded. Such readings are called automated office blood pressure (AOBP) and they are both more accurate than conventional manual office BP and not associated with the white coat phenomena. AOBP readings are also similar to the awake ambulatory BP and home BP, both of which are relatively good predictors of cardiovascular risk. The available evidence suggests that AOBP should now replace manual or electronic office BP readings when screening patients for hypertension and also after antihypertensive drug therapy is initiated. Copyright © 2018. The Korean Society of Cardiology.

  4. Arterial blood gas management in retrograde cerebral perfusion: the importance of carbon dioxide.

    Science.gov (United States)

    Ueno, K; Takamoto, S; Miyairi, T; Morota, T; Shibata, K; Murakami, A; Kotsuka, Y

    2001-11-01

    Many interventional physiological assessments for retrograde cerebral perfusion (RCP) have been explored. However, the appropriate arterial gas management of carbon dioxide (CO2) remains controversial. The aim of this study is to determine whether alpha-stat or pH-stat could be used for effective brain protection under RCP in terms of cortical cerebral blood flow (CBF), cerebral metabolic rate for oxygen (CMRO2), and distribution of regional cerebral blood flow. Fifteen anesthetized dogs (25.1+/-1.1 kg) on cardiopulmonary bypass (CPB) were cooled to 18 degrees C under alpha-stat management and had RCP for 90 min under: (1), alpha-stat; (2), pH-stat; or (3), deep hypothermic (18 degrees C) antegrade CPB (antegrade). RCP flow was regulated for a sagittal sinus pressure of around 25 mmHg. CBF was monitored by a laser tissue flowmeter. Serial analyses of blood gas were made. The regional cerebral blood flow was measured with colored microspheres before discontinuation of RCP. CBF and CMRO2 were evaluated as the percentage of the baseline level (%CBF, %CMRO2). The oxygen content of arterial inflow and oxygen extraction was not significantly different between the RCP groups. The %CBF and %CMRO2 were significantly higher for pH-stat RCP than for alpha-stat RCP. The regional cerebral blood flow, measured with colored microspheres, tended to be higher for pH-stat RCP than for alpha-stat RCP, at every site in the brain. Irrespective of CO2 management, regional differences were not significant among any site in the brain. CO2 management is crucial for brain protection under deep hypothermic RCP. This study revealed that pH-stat was considered to be better than alpha-stat in terms of CBF and oxygen metabolism in the brain. The regional blood flow distribution was considered to be unchanged irrespective of CO2 management.

  5. Pulmonary blood flow distribution measured by radionuclide computed tomography

    International Nuclear Information System (INIS)

    Maeda, H.; Itoh, H.; Ishii, Y.

    1982-01-01

    Distributions of pulmonary blood flow per unit lung volume were measured in sitting patients with a radionuclide computed tomography (RCT) by intravenously administered Tc-99m macroaggregates of human serum albumin (MAA). Four different types of distribution were distinguished, among which a group referred as type 2 had a three zonal blood flow distribution as previously reported (West and co-workers, 1964). The pulmonary arterial pressure (Pa) and the venous pressure (Pv) were determined in this group of distribution. These values showed satifactory agreements with the pulmonary artery pressure (Par) and the capillary wedged pressure (Pcw) measured by Swan-Ganz catheter in eighteen supine patients. Those good correlations enable to establish a noninvasive methodology for measurement of pulmonary vascular pressures

  6. The effect of sensory stimulation provided by family on arterial blood oxygen saturation in critical care patients.

    Science.gov (United States)

    Yousefi, Hojatollah; Naderi, Mojgan; Daryabeigi, Reza

    2015-01-01

    Stressors in the intensive care unit (ICU) impair patients' comfort, excite the stress response, and increase oxygen consumption in their body. Non-medical interventions are recommended by several studies as a treatment to improve comfort in the ICU patients. Sensory stimulation is one of the most important interventions. Since arterial blood oxygen saturation is an important index of patients' clinical and respiratory condition, this study aimed to investigate the effect of sensory stimulation provided by family on arterial blood oxygen saturation in critical care patients. This study is a clinical trial conducted on 64 patients hospitalized in the ICU wards of Al-Zahra and Kashani hospitals in Isfahan, Iran in 2012 and 2013. The patients were selected by simple sampling method and were randomly assigned to two groups (study and control). Patients' arterial blood oxygen saturations were measured 10 min before, immediately after, 10 min and 30 min after sensory stimulation in the study group, and simultaneously in the control group without any intervention. Repeated measures analysis of variance (ANOVA) showed a significant difference in the mean of arterial blood oxygen saturation levels 10 min before, immediately after, 10 min and 30 min after sensory stimulation in the study group (P 0.18). Application of sensory stimulations as a nursing and non-medical intervention by the family members improves comfort and increases the level of blood oxygen saturation in critical care patients.

  7. Effect of TIPS placement on portal and splanchnic arterial blood flow in 4-dimensional flow MRI

    Energy Technology Data Exchange (ETDEWEB)

    Stankovic, Zoran [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Roessle, Martin; Schultheiss, Michael [University Medical Center Freiburg, Department of Gastroenterology, Freiburg (Germany); Euringer, Wulf; Langer, Mathias [University Medical Center Freiburg, Department of Diagnostic Radiology and Medical Physics, Freiburg (Germany); Salem, Riad; Barker, Alex; Carr, James; Collins, Jeremy D. [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States)

    2015-09-15

    To assess changes in portal and splanchnic arterial haemodynamics in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) using four-dimensional (4D) flow MRI, a non-invasive, non-contrast imaging technique. Eleven patients undergoing TIPS implantation were enrolled. K-t GRAPPA accelerated non-contrast 4D flow MRI of the liver vasculature was applied with acceleration factor R = 5 at 3Tesla. Flow analysis included three-dimensional (3D) blood flow visualization using time-resolved 3D particle traces and semi-quantitative flow pattern grading. Quantitative evaluation entailed peak velocities and net flows throughout the arterial and portal venous (PV) systems. MRI measurements were taken within 24 h before and 4 weeks after TIPS placement. Three-dimensional flow visualization with 4D flow MRI revealed good image quality with minor limitations in PV flow. Quantitative analysis revealed a significant increase in PV flow (562 ± 373 ml/min before vs. 1831 ± 965 ml/min after TIPS), in the hepatic artery (176 ± 132 ml/min vs. 354 ± 140 ml/min) and combined flow in splenic and superior mesenteric arteries (770 ml/min vs. 1064 ml/min). Shunt-flow assessment demonstrated stenoses in two patients confirmed and treated at TIPS revision. Four-dimensional flow MRI might have the potential to give new information about the effect of TIPS placement on hepatic perfusion. It may explain some unexpected findings in clinical observation studies. (orig.)

  8. Effect of Acute Resistance Exercise on Carotid Artery Stiffness and Cerebral Blood Flow Pulsatility

    Directory of Open Access Journals (Sweden)

    Wesley K Lefferts

    2014-03-01

    Full Text Available Arterial stiffness is associated with cerebral flow pulsatility. Arterial stiffness increases following acute resistance exercise (RE. Whether this acute RE-induced vascular stiffening affects cerebral pulsatility remains unknown. Purpose: To investigate the effects of acute RE on common carotid artery (CCA stiffness and cerebral blood flow velocity (CBFv pulsatility. Methods: Eighteen healthy men (22 ± 1 yr; 23.7 ± 0.5 kg∙m-2 underwent acute RE (5 sets, 5-RM bench press, 5 sets 10-RM bicep curls with 90 s rest intervals or a time control condition (seated rest in a randomized order. CCA stiffness (β-stiffness, Elastic Modulus (Ep and hemodynamics (pulsatility index, forward wave intensity and reflected wave intensity were assessed using a combination of Doppler ultrasound, wave intensity analysis and applanation tonometry at baseline and 3 times post-RE. CBFv pulsatility index was measured with transcranial Doppler at the middle cerebral artery (MCA. Results: CCA β-stiffness, Ep and CCA pulse pressure significantly increased post-RE and remained elevated throughout post-testing (p 0.05. There were significant increases in forward wave intensity post-RE (p0.05. Conclusion: Although acute RE increases CCA stiffness and pressure pulsatility, it may not affect CCA or MCA flow pulsatility. Increases in pressure pulsatility may be due to increased forward wave intensity and not pressure from wave reflections.

  9. Spiral blood flows in an idealized 180-degree curved artery model

    Science.gov (United States)

    Bulusu, Kartik V.; Kulkarni, Varun; Plesniak, Michael W.

    2017-11-01

    Understanding of cardiovascular flows has been greatly advanced by the Magnetic Resonance Velocimetry (MRV) technique and its potential for three-dimensional velocity encoding in regions of anatomic interest. The MRV experiments were performed on a 180-degree curved artery model using a Newtonian blood analog fluid at the Richard M. Lucas Center at Stanford University employing a 3 Tesla General Electric (Discovery 750 MRI system) whole body scanner with an eight-channel cardiac coil. Analysis in two regions of the model-artery was performed for flow with Womersley number=4.2. In the entrance region (or straight-inlet pipe) the unsteady pressure drop per unit length, in-plane vorticity and wall shear stress for the pulsatile, carotid artery-based flow rate waveform were calculated. Along the 180-degree curved pipe (curvature ratio =1/7) the near-wall vorticity and the stretching of the particle paths in the vorticity field are visualized. The resultant flow behavior in the idealized curved artery model is associated with parameters such as Dean number and Womersley number. Additionally, using length scales corresponding to the axial and secondary flow we attempt to understand the mechanisms leading to the formation of various structures observed during the pulsatile flow cycle. Supported by GW Center for Biomimetics and Bioinspired Engineering (COBRE), MRV measurements in collaboration with Prof. John K. Eaton and, Dr. Chris Elkins at Stanford University.

  10. Tobacco smoking strengthens the association of elevated blood pressure with arterial stiffness: the Bogalusa Heart Study.

    Science.gov (United States)

    Yun, Miaoying; Li, Shengxu; Sun, Dianjianyi; Ge, Shaoqing; Lai, Chin-Chih; Fernandez, Camilo; Chen, Wei; Srinivasan, Sathanur R; Berenson, Gerald S

    2015-02-01

    The study assessed the hypothesis that smoking strengthens the association of adult arterial stiffness with long-term cumulative burden of blood pressure (BP) from childhood to adulthood. Tobacco smoking and elevated BPs are important risk factors of vascular stiffness. However, the synergistic effect of these two risk factors is not well established, especially for the long-term burden of elevated BP since childhood. The study cohort consisted of 945 adults (661 whites and 284 blacks, aged 24-43 years) who have BP measured 4-15 times since childhood (aged 4-17 years) in Bogalusa, Louisiana. The adult arterial stiffness was measured as aorta-femoral pulse wave velocity (afPWV); the total area under the curve (AUC) and incremental AUC were used as a measure of long-term burden and trends of BP, respectively. Increased adult afPWV was significantly associated with higher adulthood (P AUC (P AUC (P AUC (P = 0.007) were significantly greater among the current smokers than among the nonsmokers. DBP showed a similar pattern regarding the smoking-BP interaction on afPWV. These results, by showing the synergistic effect of tobacco smoking and long-term BP measures from childhood to adulthood on arterial stiffening process, underscore the importance of undertaking preventive strategies early in life and smoking behavior control.

  11. Respiratory properties of blood and arterial blood gases in the tegu lizard: effects of temperature and hypercapnia.

    Science.gov (United States)

    Wood, S C; Glass, M L; Andersen, N A; Heisler, N

    1987-01-01

    The effects of body temperature and hypercapnia (7% inspired CO2) on arterial blood gases, plasma pH, and the characteristics of the blood oxygen dissociation curve were determined in Tegu lizards (Tupinambis nigropunctatus). Arterial pH fell from 7.59 to 7.50 when body temperature was increased from 25 to 35 degrees C. The pH/temperature coefficient (delta pH/delta t = -0.009 U/degrees C) was half of that predicted on the basis of 'constant relative alkalinity' and the alphastat hypothesis. The fall in plasma pH resulted from a decrease in plasma [HCO3-], and a rise in plasma Pco2. The O2 affinity of Tegu blood, expressed by the partial pressure at half saturation (P50), decreased with temperature in vitro from 42.3 to 49.6 torr at pH 7.4. The apparent enthalpy (delta H = -3.1 kcal/mol) is about 1/4 of that of human blood. In vivo, the arterial blood oxygen saturation decreased from 89% at 25 degrees to 82% at 35 degrees C. Arterial Po2 increased from 61 to 71 torr as expected from the right-shift of the oxygen dissociation curve. During environmental hypercapnia (7% CO2, 21% O2, 72% N2 inspired concentrations), arterial pH decreased to 7.28. Arterial O2 saturation remained constant and arterial Po2 increased from 61 to 85 torr due to the right-shift of the oxygen dissociation curve. The comparatively small effect of changes in temperature on the oxygen affinity of Tegu blood (directly according to the delta H value, and indirectly via changes in blood pH) results in a relatively small right shift of the oxygen dissociation curve, and accordingly in relatively high arterial and tissue Po2 values also at higher temperatures.

  12. The origin of extrarenal arterial blood supply of renal malignancy and its clinical value

    International Nuclear Information System (INIS)

    Du Duanming; Tong Xiaoqiang; Song Li; Zou Yinghua

    2007-01-01

    Objective: To study the mechanisms of extrarenal arterial blood supply of renal malignancy for its interventional therapy. Methods: Routine abdominal aortography and selective questionable feeding arteriography were performed in 141 patients with renal malignancy. The characteristics and formation mechanisms of extrarenal arterial blood supply for renal malignancy were analyzed. Results: Of the 141 patients, extrarenal arterial blood supply of renal malignancy were found in 51 patients and there were 87 branchs. The breakthrough of renal capsule with malignancy were found in those 51 patients. No extrarenal arterial blood supply of renal malignancy was found in 90 patients, including 50 patients with and 40 patients without the renal capsule breakthrough with malignancy. The emerge of extrarenal arterial blood supply of renal malignancy were significantly different (χ 2 =31.64, P<0.01) between the patients with and without the breakthrough of renal capsule with malignancy. The origin of extrarenal arterial blood supply were correlated with the location of the tumor. Conclusions: It is important to determine the origin of the extrarenal arterial blood supply in renal malignancy for its interventional therapy. (authors)

  13. The impact of renal artery stent revascularization on blood pressure: 1-year follow-up of 110 cases

    International Nuclear Information System (INIS)

    Wang Chao; Zou Yinghua; Yang Min; Wang Jian; Tong Xiaoqiang; Song Li

    2007-01-01

    Objective: To investigate the effect of renal artery revascularization through renal artery stenting(PTRAS)on blood pressure in patients with renal artery stenosis. Methods: During April 2000 through May 2005 110 cases of renal artery stenosis received PTRAS and followed up for at least 1 year with blood pressure measurements pre-and 1 year post-PTRAS. Results: The technical success rate was 100% for all 110 cases. The renal artery stenosis were decreased from 60%-100% before PTRAS to 0%-15% after the stent placement. There was significant difference between blood pressure pre-and 1 year post PTRAS. Systolic pressures decreased from(153 ± 32) mmHg to(131 ± 27) mmHg and diastolic pressures from(87 ± 19) mmHg to(75 ± 19) mmHg. The administration of antihypertensive diugs reduced from(2.6 ± 0.9 ) sorts to(1.9 ± 0.9) sorts. Conclusions: PTRAS revascularization is an effective procedure for blood pressure control in renal vascular hypertension during one year follow up. (authors)

  14. Noninvasive estimation of pulmonary arterial pressure by analysis of pulmonary blood-flow distribution

    International Nuclear Information System (INIS)

    Konstam, M.A.; Strauss, H.W.; Alpert, N.M.; Miller, S.W.; Murphy, R.X.; Greene, R.E.; McKusick, K.A.

    1979-01-01

    To determine whether a correlation exists between pulmonary arterial (PA) pressure (P/sub a/) and the distribution of pulmonary blood flow, this distribution was measured in four upright dogs in the control state and during intravenous infusions of epinephrine or prostaglandin F/sub 2α/. During suspension of respiration, 15 mCi of Xe-133 were injected intravenously, and perfusion and equilibration lung images were recorded with a scintillation camera. The procedure was performed several times on each dog, with and without pharmacological elevation of PA pressure by 5 to 50 cm H 2 O. For each scintigram, the relative blood flow per unit ventilated lung volume (F) was plotted against centimeters above the hilum (h). Pulmonary arterial pressure was derived from each curve, assuming the relation F = B(P/sub a/ - hD) 2 , where B = constant and D = specific gravity of blood. Calculated PA pressure correlated strongly (r = 0.83) with measured PA pressure, suggesting a possible means of noninvasive estimation of PA pressure

  15. Changes in myocardial blood flow and S-T segment elevation following coronary artery occlusion in dogs

    International Nuclear Information System (INIS)

    Smith, H.J.; Singh, B.N.; Norris, R.M.; John, M.B.; Hurley, P.J.

    1975-01-01

    The relationship between regional blood flow and epicardial S-T segment elevation was studied in 26 open-chest anesthetized dogs with left anterior coronary artery ligations. Changes in myocardial blood flow, measured with 15 +- 5 μ (diameter) microspheres labeled with 141 Ce, 85 Sr, and 169 Yb, were correlated with summated S-T segment elevations 15 minutes, 1 hour, and 2 hours after coronary artery occlusion. In normal areas, myocardial blood flow was 113 +- 5 ml/min 100 g -1 and summated S-T segment elevation was 0.3 +- 0.2 mv. Fifteen minutes after coronary artery occlusion in 26 dogs, S-T segment elevation was 5.7 +- 0.7 mv over the center of the infarct and myocardial blood flow was 10 +- 1 ml/min 100 g -1 ; over the border zone, myocardial blood flow was 63 +- 4 ml/min 100 g -1 and S-T segment elevation was 3.1 +- 0.1 mv. One third of the areas with a myocardial blood flow of 10 ml/min 100 g -1 or less had no S-T segment elevation. In the center and border zones of the infarct in 9 dogs, myocardial blood flow increased from 11 +- 2 and 67 +- 8 ml/min 100 g -1 15 minutes after occlusion to 20 +- 4 and 84 +- 12 ml/min 100 g -1 , respectively, 2 hours after coronary artery occlusion. These increases were not associated with a significant reduction in summated S-T segment elevation. The results do not suggest a simple quantitative relationship between epicardial S-T segment elevation and myocardial blood flow following acute coronary artery occlusion

  16. Effects of iodinated contrast media on common carotid and brachial artery blood flow and wall shear stress

    International Nuclear Information System (INIS)

    Irace, C.; Tamburini, S.; Bertucci, B.; Franceschi, M.S. de; Gnasso, A.

    2006-01-01

    The aim of our study was to evaluate the effect of the intravenous contrast media iomeprol on wall shear stress, blood flow and vascular parameters in the common carotid and brachial artery. Thirty outpatients undergoing thoracic or abdominal spiral CT scans were studied. The internal diameter and flow velocity of the common carotid and brachial artery were evaluated by ultrasound, and blood viscosity was measured before and after low osmolality iomeprol (Iomeron 350) injection. The wall shear stress, blood flow and pulsatility index were calculated. To test the differences between groups, the Wilcoxon rank test and Mann Whitney U test were applied. Blood viscosity decreased slightly, but significantly after contrast media (4.6±0.7 vs. 4.5±0.7 mPa.s, P=0.02). Contrarily, blood flow and wall shear stress did not change in the common carotid artery, but significantly decreased in the brachial artery (0.9±0.4 vs. 0.6±0.3 ml/s, P<0.0001, and 41.5±13.9 vs. 35.3±11.0 dynes/cm2, P<0.002, respectively), whereas the pulsatility index significantly increased in the brachial artery (5.0±3.3 vs. 7.5±5.3, P<0.001). Iomeprol injection causes blood flow and wall shear stress reduction of the brachial artery; the rise in the pulsatility index suggests an increase in peripheral vascular resistance. Further investigation is needed to evaluate whether these modifications can be clinically relevant. (orig.)

  17. The relationship between exercise-induced muscle fatigue, arterial blood flow and muscle perfusion after 56 days local muscle unloading.

    Science.gov (United States)

    Weber, Tobias; Ducos, Michel; Mulder, Edwin; Beijer, Åsa; Herrera, Frankyn; Zange, Jochen; Degens, Hans; Bloch, Wilhelm; Rittweger, Jörn

    2014-05-01

    In the light of the dynamic nature of habitual plantar flexor activity, we utilized an incremental isokinetic exercise test (IIET) to assess the work-related power deficit (WoRPD) as a measure for exercise-induced muscle fatigue before and after prolonged calf muscle unloading and in relation to arterial blood flow and muscle perfusion. Eleven male subjects (31 ± 6 years) wore the HEPHAISTOS unloading orthosis unilaterally for 56 days. It allows habitual ambulation while greatly reducing plantar flexor activity and torque production. Endpoint measurements encompassed arterial blood flow, measured in the femoral artery using Doppler ultrasound, oxygenation of the soleus muscle assessed by near-infrared spectroscopy, lactate concentrations determined in capillary blood and muscle activity using soleus muscle surface electromyography. Furthermore, soleus muscle biopsies were taken to investigate morphological muscle changes. After the intervention, maximal isokinetic torque was reduced by 23·4 ± 8·2% (Pflow, tissue oxygenation, lactate concentrations and EMG median frequency kinematics during the exercise test were comparable before and after the intervention, whereas the increase of RMS in response to IIET was less following the intervention (P = 0·03). In conclusion, following submaximal isokinetic muscle work exercise-induced muscle fatigue is unaffected after prolonged local muscle unloading. The observation that arterial blood flow was maintained may underlie the unchanged fatigability. © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  18. [Comparison of invasive blood pressure measurement in the aorta with indirect oscillometric blood pressure measurement at the wrist and forearm].

    Science.gov (United States)

    Saul, F; Aristidou, Y; Klaus, D; Wiemeyer, A; Lösse, B

    1995-09-01

    Indirectly measured blood pressure at the wrist or upper arm was compared with directly measured values in the aortic arch during routinely performed diagnostic cardiac catheterization in 100 patients (31-80 years, mean 59.3 years, 60% males). The noninvasive measurements were carried out by oscillometric devices, NAiS Blood Pressure Watch for measurements at the wrist, and Hestia OZ80 at the upper arm. Systolic blood pressure measured at the wrist was 4.3 +/- 14.1 mm Hg, and the diastolic value 6.0 +/- 8.9 mm Hg higher than when measured at the aortic arch; the difference was significant in both cases. Correlation coefficients were 0.85 for systolic and 0.71 for diastolic blood pressure. In 16% of the patients the systolic blood pressure at the wrist differed more than +/- 20 mm Hg. The diastolic blood pressure at the wrist measured more than +/- 20 mm Hg higher than in the aorta in 5% of the patients. At the upper arm mean systolic values were not different to the aorta. The diastolic pressure was 9.3 +/- 9.8 mm Hg higher in the aorta than at the upper arm. To verify the accuracy of values measured with the NAiS Blood Pressure Watch compared with the standard technique at the upper arm, sequential measurements were made at wrist and ipsilateral upper arm in the same group of 100 patients. The systolic blood pressure at the left wrist was 3.4 +/- 13.3 mm Hg higher and the diastolic pressure 3.8 +/- 9.5 mm Hg lower than at the upper arm. Only 53% of systolic values lay within a range of +/- 10 mm Hg. The correspondence between wrist and upper arm values was better for diastolic blood pressure, the values differing by less than +/- 10 mm Hg in two-thirds of patients. Self-measurement of arterial blood pressure with an oscillometric device at the wrist can be recommended only in individual cases with a difference of simultaneously measured values at the upper arm of less than +/- 10 mm Hg for systolic and diastolic blood pressures. The standard method for indirectly

  19. Medida da pressão arterial e a produção científica de enfermeiros brasileiros Medida de la presion arterial y la producción científica de los enfermeros brasileños Scientific production of Brazilian nurses on blood pressure measurement

    Directory of Open Access Journals (Sweden)

    Edna Apparecida Moura Arcuri

    2007-06-01

    oldest blood pressure research line in Brazilian Nursing: "Cuff Width Influence in Blood Pressure Measurement." This new article presents the scientific production derived from the studies carried out by nurses with a PhD from EEUSP during and after their doctoral programs in the area. The path each researcher followed in his/her group and laboratory is emphasized. The data presented is aimed at offering a number of qualitative and quantitative indicators that make possible to evaluate the impact of the research that they have carried out, as well as the development of knowledge in the area.

  20. Circadian rhythm of arterial blood pressure and albuminuria in diabetic nephropathy

    DEFF Research Database (Denmark)

    Hansen, H P; Rossing, P; Tarnow, L

    1996-01-01

    The aim of our study was to evaluate the diurnal relationship between arterial blood pressure and albuminuria, and some potential mechanisms responsible for impaired nocturnal blood pressure reduction (non-dippers, groups I and II) in diabetic nephropathy (DN). Twenty-four-hour ambulatory blood p...

  1. Blood flow of the right and left submandibular gland during unilateral carotid artery occlusion in rat: role of nitric oxide.

    Science.gov (United States)

    Vág, J; Hably, C; Fazekas, A; Bartha, J

    1999-01-01

    The aim of the present study was to investigate the effect of unilateral carotid artery occlusion on the blood flow of submandibular gland in anesthetized rats and identify the role of nitric oxide (NO) in blood flow changes after the artery occlusion. L-NAME (N omega-nitro-L-arginine-methyl-ester; 10 mg/kg/day, per os) dissolved in tap water was used to block nitric oxide synthase. Glandular blood flow was measured using Sapirstein's indicator (86Rb) distribution technique. In the control animals the blood flow of left (ligated side) submandibular gland was lower than in the right (unligated side) one (right: 76.4+/-15.4 ml/min/100 g, 64.1+/-13.4 ml/min/100 g, ptinder this condition.

  2. Effects of a nitrate-rich meal on arterial stiffness and blood pressure in healthy volunteers.

    Science.gov (United States)

    Liu, Alex H; Bondonno, Catherine P; Croft, Kevin D; Puddey, Ian B; Woodman, Richard J; Rich, Lisa; Ward, Natalie C; Vita, Joseph A; Hodgson, Jonathan M

    2013-11-30

    An increase in nitrate intake can augment circulating nitrite and nitric oxide. This may lead to lower blood pressure and improved vascular function. Green leafy vegetables, such as spinach, are rich sources of nitrate. We aimed to assess the acute effects of a nitrate-rich meal containing spinach on arterial stiffness and blood pressure in healthy men and women. Twenty-six participants aged 38-69years were recruited to a randomized controlled cross-over trial. The acute effects of two energy-matched (2000kJ) meals, administered in random order, were compared. The meals were either high nitrate (220mg of nitrate derived from spinach [spinach]) or low nitrate [control]. Outcome measurements were performed pre-meal and at specific time points up to 210min post meal. Spinach resulted in an eightfold increase in salivary nitrite and a sevenfold increase in salivary nitrate concentrations from pre-meal (Pnitrate-rich meal can lower systolic blood pressure and pulse pressure and increase large artery compliance acutely in healthy men and women. If sustained, these effects could contribute to better cardiovascular health. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Relationship between segmental thallium-201 uptake and regional myocardial blood flow in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Nichols, A.B.; Weiss, M.B.; Sciacca, R.R.; Cannon, P.J.; Blood, D.K.

    1983-01-01

    The relationship between the spatial distribution of thallium-201 in myocardial perfusion scintigrams and the distribution of left ventricular regional myocardial blood flow was examined in 25 patients undergoing coronary arteriography. Thallium-201 myocardial scintigrams were obtained after symptom-limited exercise and after a 4 hr delay. Regional myocardial blood flow was measured by the xenon-133 clearance method in patients at rest and during rapid atrial pacing to a double product comparable with that achieved during exercise stress testing. Patterns of regional thallium-201 activity and regional myocardial blood flow, recorded in similar left anterior oblique projections, were compared for left ventricular segments supplied by the left anterior descending (LAD) and left circumflex (CIRC) arteries. In 11 patients without significant lesions of the left coronary artery (group 1), thallium-201 was homogeneously distributed in the LAD and CIRC distributions in scintigrams taken during peak exercise; these scintigrams correspond to homogeneous regional myocardial blood flow in the LAD and CIRC regions during pacing-induced stress. In 14 patients with significant lesions of the left coronary artery (group 2), ratios of regional thallium-201 activity in the LAD and CIRC distributions of exercise scintigrams correlated well (r . .84) with ratios of regional myocardial blood flow measured during rapid pacing. Background subtraction altered the relationship between relative thallium-201 uptake and regional myocardial blood flow, causing overestimation of the magnitude of flow reduction on exercise scintigrams

  4. Impaired increase of retinal capillary blood flow to flicker light exposure in arterial hypertension.

    Science.gov (United States)

    Ritt, Martin; Harazny, Joanna M; Ott, Christian; Raff, Ulrike; Bauernschubert, Philipp; Lehmann, Marina; Michelson, Georg; Schmieder, Roland E

    2012-09-01

    We hypothesized that the increase of retinal capillary blood flow (RCF) to flicker light exposure is impaired in subjects with arterial hypertension. In 146 nondiabetic untreated male subjects with (n=50) or without (n=96) arterial hypertension, RCF was measured before and after flicker light exposure noninvasively and in vivo using scanning laser Doppler flowmetry. In addition, in a subgroup of 28 subjects, the change of RCF to flicker light exposure was again assessed during parallel infusion of nitric oxide synthase inhibitor N-monomethyl-L-arginine (L-NMMA). The increase of RCF to flicker light exposure was lower in patients with untreated hypertension compared with normotensive subjects when expressed in absolute terms (7.69±54 versus 27.2±44 AU; P adjusted=0.013) or percent changes (2.95±14 versus 8.33±12%; P adjusted=0.023). Systolic (β=-0.216; P=0.023) but not diastolic blood pressure (β=-0.117; P=0.243) or mean arterial pressure (β=-0.178; P=0.073) was negatively related to the percent change of RCF to flicker light exposure, independently of other cardiovascular risk factors. In the subgroup of 28 subjects, the increase of RCF to flicker light exposure was similar at baseline and during parallel infusion of L-NMMA when expressed in absolute terms (20.0±51 versus 22.6±56 AU; P=0.731) or percent changes (7.12±16 versus 8.29±18%; P=0.607). The increase of RCF to flicker light exposure is impaired in arterial hypertension. In the subgroup of the total study cohort, nitric oxide was not a major determinant of the increase of RCF to flicker light exposure.

  5. [Baroreflexes originated in vertebral artery zones upon peripheral vein tonus, systemic arterial blood pressure, and external respiration].

    Science.gov (United States)

    Agadzhanian, N A; Kupriianov, S V

    2008-06-01

    The investigation was intended to study the role ofbaroreceptors ofhemodynamically isolated zone of vertebral arteries in regulation of peripheral veins tonus, arterial pressure and external respiration. Pressure decrease in this vascular reflexogenic zone led to reflex responses of increase in femoral vein tonus, elevation of blood pressure level and stimulation of external respiration. The opposite reflex responses of cardio-respiratory functional system to initial pressure activation of vertebral arteries baroreceptors are observed. Basing on generalization of our own findings and similar physiological and morphological researches of other authors, it is established that afferentation from the vertebral artery zone is a reflexogenic factor of somatic muscles' veins tonus regulation. These reflexes of capacity vessels tonic activity changes are part of cardio-respiratory responses of maintaining the tissue gaseous exchange.

  6. Obese children and adolescents have elevated nighttime blood pressure independent of insulin resistance and arterial stiffness

    DEFF Research Database (Denmark)

    Hvidt, Kristian N; Olsen, Michael H; Holm, Jens-Christian

    2014-01-01

    BACKGROUND: Insulin resistance has been related to elevated blood pressure (BP) in obese children and may adversely affect the vasculature by arterial stiffening. The objective was to investigate whether daytime and nighttime BP were elevated and related to insulin resistance and arterial stiffness...... in obese children and adolescents. METHODS: Ninety-two obese patients aged 10-18 years were compared with 49 healthy control individuals. Insulin resistance was measured as the homeostatic assessment model (HOMA), and arterial stiffness was measured as carotid-femoral pulse wave velocity (cfPWV). RESULTS......: Mean ± SD daytime systolic BP (SBP) (obese: 125±8.3mm Hg; control: 121±10.1mm Hg; P = 0.03) and nighttime SBP (obese: 108±10.7mm Hg; control: 102±8.2mm Hg; P = 0.0001) were higher in the obese group when compared with the control group. No difference was found in daytime diastolic BP (DBP), whereas...

  7. Intraoperative changes of transcranial Doppler velocity: relation to arterial oxygen content and whole-blood viscosity

    NARCIS (Netherlands)

    Schuurman, P. R.; Albrecht, K. W.

    1999-01-01

    The association of arterial oxygen content (CaO2) and viscosity with transcranial Doppler (TCD) blood flow velocity in the middle cerebral artery was studied in 20 adults without cerebrovascular disease undergoing abdominal surgery associated with significant fluctuations in hematology. TCD

  8. A Comparison of Po2, Pco2, Ph and Bicarbonate in Blood from the Carotid and Coccygeal Arteries of Calves

    OpenAIRE

    Gustin, Pascal; de Groote, A.; Dhem, A. R.; Bakima, M.; Lomba; Lekeux, Pierre

    1988-01-01

    A technique is described for the subcutaneous deviation of the carotid artery into the jugular groove of calves weighing between 90 and 200 kg. This makes sampling arterial blood or chronic cannulation for further experimentation very easy. Values of oxygen tension, carbon dioxide tension, pH and bicarbonate concentration in blood sampled from the ventral coccygeal artery were compared with the values obtained in blood from carotid artery puncture. The high correlations observed indicate that...

  9. Decreased muscle oxygenation and increased arterial blood flow in the non-exercising limb during leg exercise.

    Science.gov (United States)

    Shiroishi, Kiyoshi; Kime, Ryotaro; Osada, Takuya; Murase, Norio; Shimomura, Kousuke; Katsumura, Toshihito

    2010-01-01

    We evaluated arterial blood flow, muscle tissue oxygenation and muscle metabolism in the non-exercising limb during leg cycling exercise. Ten healthy male volunteers performed a graded leg cycling exercise at 0, 40, 80, 120 and 160 watts (W) for 5 min each. Tissue oxygenation index (TOI) of the non-exercising left forearm muscle was measured using a near-infrared spatially resolved spectroscopy (NIR(SRS)), and non-exercising forearm blood flow ((NONEX)FBF) in the brachial artery was also evaluated by a Doppler ultrasound system. We also determined O(2) consumption of the non-exercising forearm muscle (NONEXV(O)(2mus)) by the rate of decrease in O(2)Hb during arterial occlusion at each work rate. TOI was significantly decreased at 160 W (p exercising muscle may be reduced, even though (NONEX)FBF increases at high work rates during leg cycling exercise.

  10. Blood Pressure Response to Main Renal Artery and Combined Main Renal Artery Plus Branch Renal Denervation in Patients With Resistant Hypertension.

    Science.gov (United States)

    Fengler, Karl; Ewen, Sebastian; Höllriegel, Robert; Rommel, Karl-Philipp; Kulenthiran, Saaraaken; Lauder, Lucas; Cremers, Bodo; Schuler, Gerhard; Linke, Axel; Böhm, Michael; Mahfoud, Felix; Lurz, Philipp

    2017-08-10

    Single-electrode ablation of the main renal artery for renal sympathetic denervation showed mixed blood pressure (BP)-lowering effects. Further improvement of the technique seems crucial to optimize effectiveness of the procedure. Because sympathetic nerve fibers are closer to the lumen in the distal part of the renal artery, treatment of the distal main artery and its branches has been shown to reduce variability in treatment effects in preclinical studies and a recent randomized trial. Whether this optimized technique improves clinical outcomes remains uncertain. We report a 2-center experience of main renal artery and combined main renal artery plus branches renal denervation in patients with resistant hypertension using a multielectrode catheter. Twenty-five patients with therapy-resistant hypertension underwent renal sympathetic denervation with combined main renal artery and renal branch ablation and were compared to matched controls undergoing an ablation of the main renal artery only. BP change was assessed by ambulatory measurement at baseline and after 3 months. At baseline, BP was balanced between the groups. After 3 months, BP changed significantly in the combined ablation group (systolic/diastolic 24-hour mean and daytime mean BP -8.5±9.8/-7.0±10.7 and -9.4±9.8/-7.1±13.5 mm Hg, P renal artery and branches appears to improve BP-lowering efficacy and should be further investigated. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  11. Blood pressure and anthropometric measurements in healthy ...

    African Journals Online (AJOL)

    Methods. We measured the blood pressures of 650 healthy, randomly ... In addition, blood pressure measurement should be a part of the routine clinical examination of children. ... familial risk factors.2 ... common cause of elevated blood pressure in children.4 They ... sphygmomanometer (Accoson, hospital model BS 274,.

  12. Improved arterial blood oxygenation following intravenous infusion of cold supersaturated dissolved oxygen solution.

    Science.gov (United States)

    Grady, Daniel J; Gentile, Michael A; Riggs, John H; Cheifetz, Ira M

    2014-01-01

    One of the primary goals of critical care medicine is to support adequate gas exchange without iatrogenic sequelae. An emerging method of delivering supplemental oxygen is intravenously rather than via the traditional inhalation route. The objective of this study was to evaluate the gas-exchange effects of infusing cold intravenous (IV) fluids containing very high partial pressures of dissolved oxygen (>760 mm Hg) in a porcine model. Juvenile swines were anesthetized and mechanically ventilated. Each animal received an infusion of cold (13 °C) Ringer's lactate solution (30 mL/kg/hour), which had been supersaturated with dissolved oxygen gas (39.7 mg/L dissolved oxygen, 992 mm Hg, 30.5 mL/L). Arterial blood gases and physiologic measurements were repeated at 15-minute intervals during a 60-minute IV infusion of the supersaturated dissolved oxygen solution. Each animal served as its own control. Five swines (12.9 ± 0.9 kg) were studied. Following the 60-minute infusion, there were significant increases in PaO2 and SaO2 (P < 0.05) and a significant decrease in PaCO2 (P < 0.05), with a corresponding normalization in arterial blood pH. Additionally, there was a significant decrease in core body temperature (P < 0.05) when compared to the baseline preinfusion state. A cold, supersaturated dissolved oxygen solution may be intravenously administered to improve arterial blood oxygenation and ventilation parameters and induce a mild therapeutic hypothermia in a porcine model.

  13. Influence of hemodialysis on the mean blood flow velocity in the middle cerebral artery.

    Science.gov (United States)

    Stefanidis, I; Bach, R; Mertens, P R; Liakopoulos, V; Liapi, G; Mann, H; Heintz, B

    2005-08-01

    Several effects of hemodialysis, including hemoconcentration, alterations of hemostasis or hemorheology and endothelial activation, could potentially interfere with cerebral blood flow (CBF) regulation. These treatment-specific changes may also be crucial for the enhanced incidence of stroke in uremic patients. Nevertheless, the influence of hemodialysis on CBF has not been yet adequately studied. We registered mean blood flow velocity (MFV) in the middle cerebral artery (MCA) during hemodialysis treatment in order to evaluate its contribution on CBF changes. Transcranial Doppler ultrasonography (TCD) of the MCA was performed continuously during hemodialysis treatment in 18 stable patients (10 males and 8 females, mean age 62 +/- 11 years) with end-stage renal disease of various origin. Blood pressure (mmHg), heart rate (/min), ultrafiltration volume (ml), BV changes (deltaBV by hemoglobinometry, %), arterial blood gases (pO2, blood oxygen content, pCO2), hemostasis activation (thrombin-antithrombin III complex, ELISA) and fibrinogen (Clauss) were measured simultaneously at the beginning of treatment and every hour thereafter. Before the hemodialysis session the MFV in the MCA was within normal range (57.5 +/- 13.0 cm/s, ref. 60 +/- 12) and was mainly dependent on the patients' age (r = -0.697, p delta%MFV) were interrelated to the ultrafiltration volume (r = -0.486, p delta%acO2, r = -0.420, p delta%fibrinogen, r = 0.244, p < 0.05). A significant continuous decrease of the MFV in the MCA was observed during hemodialysis treatment, which inversely correlated both with ultrafiltration volume, BV changes and changes of plasma fibrinogen. The ultrafiltration-induced hemoconcentration with concomitant rise of hematocrit and oxygen transport capacity, may partly explain the alterations in the cerebral MFV observed during hemodialysis.

  14. Respiratory sinus arrhythmia stabilizes mean arterial blood pressure at high-frequency interval in healthy humans.

    Science.gov (United States)

    Elstad, Maja; Walløe, Lars; Holme, Nathalie L A; Maes, Elke; Thoresen, Marianne

    2015-03-01

    Arterial blood pressure variations are an independent risk factor for end organ failure. Respiratory sinus arrhythmia (RSA) is a sign of a healthy cardiovascular system. However, whether RSA counteracts arterial blood pressure variations during the respiratory cycle remains controversial. We restricted normal RSA with non-invasive intermittent positive pressure ventilation (IPPV) to test the hypothesis that RSA normally functions to stabilize mean arterial blood pressure. Ten young volunteers were investigated during metronome-paced breathing and IPPV. Heart rate (ECG), mean arterial blood pressure and left stroke volume (finger arterial pressure curve) and right stroke volume (pulsed ultrasound Doppler) were recorded, while systemic and pulmonary blood flow were calculated beat-by-beat. Respiratory variations (high-frequency power, 0.15-0.40 Hz) in cardiovascular variables were estimated by spectral analysis. Phase angles and correlation were calculated by cross-spectral analysis. The magnitude of RSA was reduced from 4.9 bpm(2) (95% CI 3.0, 6.2) during metronome breathing to 2.8 bpm(2) (95% CI 1.1, 5.0) during IPPV (p = 0.03). Variations in mean arterial blood pressure were greater (2.3 mmHg(2) (95% CI 1.4, 3.9) during IPPV than during metronome breathing (1.0 mmHg(2) [95% CI 0.7, 1.3]) (p = 0.014). Respiratory variations in right and left stroke volumes were inversely related in the respiratory cycle during both metronome breathing and IPPV. RSA magnitude is lower and mean arterial blood pressure variability is greater during IPPV than during metronome breathing. We conclude that in healthy humans, RSA stabilizes mean arterial blood pressure at respiratory frequency.

  15. Combined exercise reduces arterial stiffness, blood pressure, and blood markers for cardiovascular risk in postmenopausal women with hypertension.

    Science.gov (United States)

    Son, Won-Mok; Sung, Ki-Dong; Cho, Jae-Min; Park, Song-Young

    2017-03-01

    Postmenopausal women exhibit elevated brachial-ankle pulse wave velocity (baPWV), an indicator of arterial stiffness, which is associated with an increased risk of cardiovascular events and mortality. The purpose of this study is to examine the impact of combined resistance and aerobic exercise training on baPWV, blood pressure (BP), and cardiovascular fitness in postmenopausal women with stage 1 hypertension. Twenty postmenopausal women (age, 75 ± 2 y; systolic BP, 152 ± 2 mm Hg, diastolic BP, 95 ± 3 mm Hg) were randomly assigned to a "no-exercise" (CON, n = 10) or combined exercise (EX, n = 10) group. The EX group performed resistance and aerobic exercise for 12 weeks, 3 times per week. Exercise intensity was increased gradually, from 40% to 70% of heart rate reserve, every 4 weeks. BaPWV, BP, blood nitrite/nitrate, endothelin-1 (ET-1), cardiovascular fitness, and body composition were measured before and after the 12-week intervention. BP, baPWV (-1.2 ± 0.4 m/s), ET-1 (-2.7 ± 0.3 μmol/mL), nitrite/nitrate (+4.5 ± 0.5 μM), functional capacity, and body composition were significantly improved (P exercise training improves arterial stiffness, BP, ET-1, blood nitrite/nitrate, functional capacity, and body composition in postmenopausal women with stage 1 hypertension. Thus, this study provides evidence that combined exercise training is a useful therapeutic method to improve cardiovascular health which can reduce cardiovascular disease risk in postmenopausal women with hypertension.

  16. The influence of the non-Newtonian properties of blood on blood-hammer through the posterior cerebral artery.

    Science.gov (United States)

    Tazraei, Pedram; Riasi, Alireza; Takabi, Behrouz

    2015-06-01

    This work investigates a two dimensional numerical analysis of blood hammer through the posterior cerebral artery. The non-Newtonian and usual Newtonian blood models are compared in the case of blood hammer through the posterior cerebral artery to quantify the differences between the models. In this way, a validated CFD simulation is used to study non-Newtonian shear-thinning effects of blood. The governing equations for the modeling of two-dimensional transient flow are solved using a combination of characteristics and central finite difference methods, respectively for the hyperbolic and parabolic parts. Herein, the non-Newtonian viscosity characteristic of blood is incorporated by using the Carreau model. To convert the nonlinear terms available in the characteristics equation into the linear ones, the Newton-Kantorovich method is implemented. The verification and validation of the numerical results are carried out in detail. Hemodynamic characteristics of blood hammer through the posterior cerebral artery are derived with both the Newtonian and non-Newtonian models, and the results are meticulously compared and discussed. The results show that when blood hammer occurs, the non-Newtonian properties greatly influence the velocity and shear stress profiles. At the early stages of blood hammer, there is a 64% difference between magnitudes of wall shear stress in these two models, and the magnitude of the wall shear stress for the shear-thinning blood flow is lower than the Newtonian one. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Glucose Pump Test can be Used to Measure Blood Flow Rate of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... In 93 chronic hemodialysis patients with native AV fistula, blood flow rates were measured by Doppler US .... Arterial blood pressure from nonvascular access arm was measured by aneroid sphygmomanometer. The patients did not .... to detect differences in treatments across multiple test attempts. P < 0.05 ...

  18. [Basic laws of blood screw motion in human common carotid arteries].

    Science.gov (United States)

    Kulikov, V P; Kirsanov, R I

    2008-08-01

    The basic laws of blood screw motion in common carotid arteries in people were determined by means of modern ultrasound techniques for the first time. 92 healthy adults, aged 18-30, were examined. The blood flow in the middle one-third of common carotid arteries was registered by means of Color Doppler Imaging and impulse Doppler with the help of ultrasound Medison 8000EX scanner by linear transducer of 5-9 MHz. The steady registration of blood screw motion in both common carotid arteries in Color Doppler Imaging regimen was observed in 54.3 % of cases. The direction of screw stream rotation in most cases (54%) was multi-directed: in the right common carotid artery it was right, in the left common carotid artery--left (48%), and in 6% of cases it was reverse. For 46% of cases blood rotation in both common carotid arteries was one-directed (26%--right, 20%--left). The velocity parameters of rotation component of blood motion were determined, maximum velocity being 19.68 +/- 5.84 cm/sec, minimum--4.57 +/- 2.89 cm/sec, average--7.48 +/- 2.49 cm/sec, angular--10.7 +/- 2.49 sec(-1). The rated velocity of blood cells motion in screw motion with regard of screw current lines to the vessel vertical axis makes up from 158.67 +/- 32.79 to 224.39 +/- 46.37 cm/sec.

  19. A common humoral background of intraocular and arterial blood pressure dysregulation.

    Science.gov (United States)

    Skrzypecki, Janusz; Grabska-Liberek, Iwona; Przybek, Joanna; Ufnal, Marcin

    2018-03-01

    It has been postulated that intraocular pressure, an important glaucoma risk factor, correlates positively with arterial blood pressure (blood pressure). However, results of experimental and clinical studies are often contradictory. It is hypothesized that, in some hypertensive patients, disturbances in intraocular pressure regulation may depend on biological effects of blood borne hormones underlying a particular type of hypertension, rather than on blood pressure level itself. This review compares the effects of hormones on blood pressure and intraocular pressure, in order to identify a hormonal profile of hypertensive patients with an increased risk of intraocular pressure surge. The PUBMED database was searched to identify pre-clinical and clinical studies investigating the role of angiotensin II, vasopressin, adrenaline, noradrenaline, prostaglandins, and gaseous transmitters in the regulation of blood pressure and intraocular pressure. Studies included in the review suggest that intraocular and blood pressures often follow a different pattern of response to the same hormone. For example, vasopressin increases blood pressure, but decreases intraocular pressure. In contrast, high level of nitric oxide decreases blood pressure, but increases intraocular pressure. Arterial hypertension is associated with altered levels of blood borne hormones. Contradicting results of studies on the relationship between arterial hypertension and intraocular pressure might be partially explained by diverse effects of hormones on arterial and intraocular pressures. Further studies are needed to evaluate if hormonal profiling may help to identify glaucoma-prone patients.

  20. Accuracy of Transcutaneous CO2 Values Compared With Arterial and Capillary Blood Gases.

    Science.gov (United States)

    Lambert, Laura L; Baldwin, Melissa B; Gonzalez, Cruz Velasco; Lowe, Gary R; Willis, J Randy

    2018-05-08

    Transcutaneous monitors are utilized to monitor a patient's respiratory status. Some patients have similar values when comparing transcutaneous carbon dioxide ( P tcCO 2 ) values with blood gas analysis, whereas others show extreme variability. A retrospective review of data was performed to determine how accurately P tcCO 2 correlated with CO 2 values obtained by arterial blood gas (ABG) or capillary blood gas. To determine whether P tcCO 2 values correlated with ABG or capillary blood gas values, subjects' records were retrospectively reviewed. Data collected included the P tcCO 2 value at the time of blood gas procurement and the ABG or capillary blood gas P CO 2 value. Agreement of pairs of methods (ABG vs P tcCO 2 and capillary blood gas vs P tcCO 2 ) was assessed with the Bland-Altman approach with limits of agreement estimated with a mixed model to account for serial measurements per subject. A total of 912 pairs of ABG/ P tcCO 2 values on 54 subjects and 307 pairs of capillary blood gas/ P tcCO 2 values on 34 subjects were analyzed. The P CO 2 range for ABG was 24-106 mm Hg, and P tcCO 2 values were 27-133 mm Hg. The P CO 2 range for capillary blood gas was 29-108 mm Hg, and P tcCO 2 values were 30-103 mm Hg. For ABG/ P tcCO 2 comparisons, the Pearson correlation coefficient was 0.82, 95% CI was 0.80-0.84, and P was <.001. For capillary blood gas/ P tcCO 2 comparisons, the Pearson correlation coefficient was 0.77, 95% CI was 0.72-0.81, and P was <.001. For ABG/ P tcCO 2 , the estimated difference ± SD was -6.79 t± 7.62 mm Hg, and limits of agreement were -22.03 to 8.45. For capillary blood gas/ P tcCO 2 , the estimated difference ± SD was -1.61 ± 7.64 mm Hg, and limits of agreement were -16.88 to 13.66. The repeatability coefficient was about 30 mm Hg. Based on these data, capillary blood gas comparisons showed less variation and a slightly lower correlation with P tcCO 2 than did ABG comparisons. After accounting for serial measurements per patient

  1. EFFECT OF LISINOPRIL ON 24-HOUR BLOOD PRESSURE AND ARTERIAL STIFFNESS IN PATIENTS WITH ARTERIAL HYPERTENSION AND RHEUMATOID ARTHRITIS

    Directory of Open Access Journals (Sweden)

    O. L. Sarkisova

    2017-01-01

    Full Text Available Aim. To study effect of 24-week treatment with lisinopril on blood pressure (BP and arterial stiffness in patients with arterial hypertension (HT and rheumatoid arthritis (RA.Material and methods. Twenty patients with essential HT grade  1-2 and RA (mean age 60.2±7.9 years were treated with lisinoprilin 24 weeks in open controlled study. Office blood pressure (BP was 147.2±9.4/87.5±8.6 mm Hg; 24-h mean  BP – 141.8±9.3/82.2±9.6 mm Hg; HT duration was 14.5±9.4 years, and RA duration – 12.3±2.6 years. A high incidence of traditional cardiovascular risk factors was identified: 95% of patients had dyslipidaemia, 45% – obesity, 35% – impaired glucose tolerance. Atherosclerosis of carotid arteries with stenosis less than 25% was diagnosed in 65% of patients. Most patients had a positive rheumatoid factor and cyclic citrullinated peptide antibodies, as well as moderate RA activity and III-IV radiologic stage of RA. All patients received methotrexate as the basic anti-inflammatory drug, 12 (60% patients – selective cyclooxygenase-2 inhibitors, 6 (30% patients took corticosteroids equivalent to prednisolone 7.5±5.5 mg per day. Mean  dose  of lisinopril was 12.2±9.8 mg/day. Office BP measurements, 24-hour ambulatory BP monitoring (ABPM, and  arterial stiffness evaluation were  performed initially and  at the end of the study. Arterial stiffness was assessed by cardio-ankle vascular index on the right (R-CAVI and on the left (L-CAVI.Results. After 24-week therapy with lisinopril office systolic and diastolic BP significantly decreased by 16.0±7.2/11.6±9.1 mm Hg (p<0.0001 and 11.6±9.1 mm Hg (p<0.0001, respectively. The target BP was achieved in 16 (83% patients. According to the ABPM 24-week therapy with lisino pril led to a significant (p<0.002 decrease in BP for all referable periods: by 12.4±9.1/7.6±3.9 mm Hg within 24 hours;  by 13.4±10.1/8.0±6.1 mm Hg for daytime; by 10.1±9.3/7.3±6.3 mm Hg for night-time. After

  2. Investigating complex patterns of blocked intestinal artery blood pressure signals by empirical mode decomposition and linguistic analysis

    International Nuclear Information System (INIS)

    Yeh, J-R; Lin, T-Y; Shieh, J-S; Chen, Y; Huang, N E; Wu, Z; Peng, C-K

    2008-01-01

    In this investigation, surgical operations of blocked intestinal artery have been conducted on pigs to simulate the condition of acute mesenteric arterial occlusion. The empirical mode decomposition method and the algorithm of linguistic analysis were applied to verify the blood pressure signals in simulated situation. We assumed that there was some information hidden in the high-frequency part of the blood pressure signal when an intestinal artery is blocked. The empirical mode decomposition method (EMD) has been applied to decompose the intrinsic mode functions (IMF) from a complex time series. But, the end effects and phenomenon of intermittence damage the consistence of each IMF. Thus, we proposed the complementary ensemble empirical mode decomposition method (CEEMD) to solve the problems of end effects and the phenomenon of intermittence. The main wave of blood pressure signals can be reconstructed by the main components, identified by Monte Carlo verification, and removed from the original signal to derive a riding wave. Furthermore, the concept of linguistic analysis was applied to design the blocking index to verify the pattern of riding wave of blood pressure using the measurements of dissimilarity. Blocking index works well to identify the situation in which the sampled time series of blood pressure signal was recorded. Here, these two totally different algorithms are successfully integrated and the existence of the existence of information hidden in high-frequency part of blood pressure signal has been proven

  3. Investigating complex patterns of blocked intestinal artery blood pressure signals by empirical mode decomposition and linguistic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yeh, J-R; Lin, T-Y; Shieh, J-S [Department of Mechanical Engineering, Yuan Ze University, 135 Far-East Road, Chung-Li, Taoyuan, Taiwan (China); Chen, Y [Far Eastern Memorial Hospital, Taiwan (China); Huang, N E [Research Center for Adaptive Data Analysis, National Central University, Taiwan (China); Wu, Z [Center for Ocean-Land-Atmosphere Studies (United States); Peng, C-K [Beth Israel Deaconess Medical Center, Harvard Medical School (United States)], E-mail: s939205@ mail.yzu.edu.tw

    2008-02-15

    In this investigation, surgical operations of blocked intestinal artery have been conducted on pigs to simulate the condition of acute mesenteric arterial occlusion. The empirical mode decomposition method and the algorithm of linguistic analysis were applied to verify the blood pressure signals in simulated situation. We assumed that there was some information hidden in the high-frequency part of the blood pressure signal when an intestinal artery is blocked. The empirical mode decomposition method (EMD) has been applied to decompose the intrinsic mode functions (IMF) from a complex time series. But, the end effects and phenomenon of intermittence damage the consistence of each IMF. Thus, we proposed the complementary ensemble empirical mode decomposition method (CEEMD) to solve the problems of end effects and the phenomenon of intermittence. The main wave of blood pressure signals can be reconstructed by the main components, identified by Monte Carlo verification, and removed from the original signal to derive a riding wave. Furthermore, the concept of linguistic analysis was applied to design the blocking index to verify the pattern of riding wave of blood pressure using the measurements of dissimilarity. Blocking index works well to identify the situation in which the sampled time series of blood pressure signal was recorded. Here, these two totally different algorithms are successfully integrated and the existence of the existence of information hidden in high-frequency part of blood pressure signal has been proven.

  4. Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots.

    Science.gov (United States)

    Acierno, Mark J; da Cunha, Anderson; Smith, Julie; Tully, Thomas N; Guzman, David Sanchez-Migallon; Serra, Verna; Mitchell, Mark A

    2008-11-15

    To determine the level of agreement between direct and indirect blood pressure measurements obtained from healthy Hispaniolan Amazon parrots (Amazona ventralis) anesthetized with isoflurane. Validation study. 16 healthy adult Hispaniolan Amazon parrots. Parrots were anesthetized, and a 26-gauge, 19-mm catheter was placed percutaneously in the superficial ulnar artery for direct measurement of systolic, mean, and diastolic arterial pressures. Indirect blood pressure measurements were obtained with a Doppler ultrasonic flow detector and an oscillometric unit. The Bland-Altman method was used to compare direct and indirect blood pressure values. There was substantial disagreement between direct systolic arterial blood pressure and indirect blood pressure measurements obtained with the Doppler detector from the wing (bias, 24 mm Hg; limits of agreement, -37 to 85 mm Hg) and from the leg (bias, 14 mm Hg; limits of agreement, -14 to 42 mm Hg). Attempts to obtain indirect blood pressure measurements with the oscillometric unit were unsuccessful. Results suggested that there was substantial disagreement between indirect blood pressure measurements obtained with a Doppler ultrasonic flow detector in anesthetized Hispaniolan Amazon parrots and directly measured systolic arterial blood pressure.

  5. CT perfusion of the liver during selective hepatic arteriography. Pure arterial blood perfusion of liver tumor and parenchyma

    International Nuclear Information System (INIS)

    Komemushi, Atsushi; Tanigawa, Noboru; Kojima, Hiroyuki; Kariya, Shuji; Sawada, Satoshi

    2003-01-01

    The purpose of this study was to quantify pure arterial blood perfusion of liver tumor and parenchyma by using CT perfusion during selective hepatic arteriography. A total of 44 patients underwent liver CT perfusion study by injection of contrast medium via the hepatic artery. CT-perfusion parameters including arterial blood flow, arterial blood volume, and arterial mean transit time in the liver parenchyma and liver tumor were calculated using the deconvolution method. The CT-perfusion parameters and vascularity of the tumor were compared. A complete analysis could be performed in 36 of the 44 patients. For liver tumor and liver parenchyma, respectively, arterial blood flow was 184.6±132.7 and 41.0±27.0 ml/min/100 g, arterial blood volume was 19.4±14.6 and 4.8±4.2 ml/100 g, and arterial mean transit time was 8.9±4.2 and 10.2±5.3 sec. Arterial blood flow and arterial blood volume correlated significantly with the vascularity of the tumor; however no correlation was detected between arterial mean transit time and the vascularity of the tumor. This technique could be used to quantify pure hepatic arterial blood perfusion. (author)

  6. Assessment of carbon monoxide values in smokers: a comparison of carbon monoxide in expired air and carboxyhaemoglobin in arterial blood

    DEFF Research Database (Denmark)

    Andersson, Mette F; Møller, Ann M

    2010-01-01

    Smoking increases perioperative complications. Carbon monoxide concentrations can estimate patients' smoking status and might be relevant in preoperative risk assessment. In smokers, we compared measurements of carbon monoxide in expired air (COexp) with measurements of carboxyhaemoglobin (COHb) ......) in arterial blood. The objectives were to determine the level of correlation and to determine whether the methods showed agreement and evaluate them as diagnostic tests in discriminating between heavy and light smokers....

  7. Blood transfusion requirement in surgery for femoral artery aneurysms

    DEFF Research Database (Denmark)

    Levi, N; Schroeder, T V

    1997-01-01

    Audit of blood usage in various surgical specialities have shown that over-ordering of blood is widespread, causing unnecessary pressure on the transfusion facilities and giving growing concern over the expense of cross-matching blood. The aim of this study was to assess the blood transfusion...

  8. Blood flows in the maxillocarotid anastomoses and internal carotid artery of conscious dogs.

    Science.gov (United States)

    Lee, M C; Reid, I A; Ramsay, D J

    1986-06-01

    Although the external carotid artery is known to contribute to the cerebral blood flow in anesthetized dogs, quantitative information on the anastomoses and their role in conscious dogs is lacking. This study was carried out to determine blood flows in these anastomoses and the internal carotid artery, and also to examine the functional significance of the anastomoses in conscious dogs. Fifteen-micron radioactive microspheres were injected into common and external carotid arteries of four conscious dogs through chronically implanted catheters. Blood flows were determined by the reference sample method and by comparing microsphere distributions in the brain and the masseter muscle. Blood flows were estimated to be 140 +/- 32, 7.7 +/- 1.4, and 3.3 +/- 1.1 ml/minute (mean +/- SD) in the common carotid artery, internal carotid artery, and anastomoses on each side, respectively. Additional evidence indicated that the anastomotic flow so determined was primarily the flow in the anastomotic artery. Humoral responses to angiotensin II infusions were also studied in conscious dogs. External carotid angiotensin increased plasma 11-hydroxycorticosteroid concentration (used as an index of ACTH secretion) but did not increase plasma vasopressin concentration to the same extent as common carotid infusion. Therefore, the external carotid artery is functionally important in perfusing the brain in conscious dogs.

  9. No benefit of intraoperative whole blood sequestration and autotransfusion during coronary artery bypass grafting : results of a randomized clinical trial

    NARCIS (Netherlands)

    Ramnath, A N; Naber, H R; de Boer, A; Leusink, J A

    OBJECTIVES: In a randomized clinical trial of patients undergoing elective coronary artery bypass grafting, we evaluated the effect of intraoperative whole blood sequestration and autotransfusion on postoperative blood loss and the use of allogeneic blood products. METHODS: Male patients were

  10. Radiolabeled microsphere measurements of alveolar bone blood flow in dogs

    International Nuclear Information System (INIS)

    Kaplan, M.L.; Jeffcoat, M.K.; Goldhaber, P.

    1978-01-01

    Radiolabeled microspheres were injected into the left cardiac ventricle in healthy adult dogs to quantify blood in maxillary and mandibular alveolar bone. Heart rate, arterial blood pressure and pulse contour were monitored throughout each experiment. Blood flow in maxillary alveolar bone was more than 30 % greater (p<.001) than in mandibular alveolar bone. Alveolar bone blood flow (mean +- S.D.) measured as ml/min per gram was 0.12 +- .02 in the maxilla compared to 0.09 +- .02 in the mandible. The cardiovascular parameters monitored were constant immediately prior to the injection of microspheres and remained unchanged during and following injection. It is possible that radiolabeled microspheres can be used to quantify the circulatory changes in alveolar bone during the development of destructive periodontal disease in dogs. (author)

  11. Contribution of spiral artery blood flow changes assessed by transvaginal color Doppler sonography for predicting endometrial pathologies

    Directory of Open Access Journals (Sweden)

    Suna Kabil Kucur

    2013-01-01

    Full Text Available ive: To investigate the diagnostic value of blood flow measurements in spiral artery by transvaginal color Doppler sonography (CDS in predicting endometrial pathologies.Methods: Ninety-seven patients presenting with abnormal uterine bleeding and requiring endometrial assessment were included in this prospective observational study. Endometrial thickness, structure and echogenicity were recorded. Pulsatility index (PI and resistive index (RI of the spiral artery were measured by transvaginal CDS. Endometrial sampling was performed for all subjects. Sonographic and hystopathologic findings were compared.Results: The histopathological diagnoses were as follows; 39 cases (40.2% endometrial polyp, 9 cases (9.3% endometrial hyperplasia, 10 cases (10.3 submucous myoma, 7 cases (7.2% endometrium cancer, and 32 cases (33% nonspecific findings. The spiral artery PI in endometrium cancer group was highly significantly lower than other groups (p<0.01. The spiral artery RI was also significantly lower in the patients with malignant histology (p<0.05. Conclusion: Endometrial pathologies are associated significantly with endometrial spiral artery Doppler changes.Key words: Spiral artery, Doppler ultrasonography, endometrium

  12. Blood pressure and calf muscle oxygen extraction during plantar flexion exercise in peripheral artery disease.

    Science.gov (United States)

    Luck, J Carter; Miller, Amanda J; Aziz, Faisal; Radtka, John F; Proctor, David N; Leuenberger, Urs A; Sinoway, Lawrence I; Muller, Matthew D

    2017-07-01

    Peripheral artery disease (PAD) is an atherosclerotic vascular disease that affects 200 million people worldwide. Although PAD primarily affects large arteries, it is also associated with microvascular dysfunction, an exaggerated blood pressure (BP) response to exercise, and high cardiovascular mortality. We hypothesized that fatiguing plantar flexion exercise that evokes claudication elicits a greater reduction in skeletal muscle oxygenation (SmO 2 ) and a higher rise in BP in PAD compared with age-matched healthy subjects, but low-intensity steady-state plantar flexion elicits similar responses between groups. In the first experiment, eight patients with PAD and eight healthy controls performed fatiguing plantar flexion exercise (from 0.5 to 7 kg for up to 14 min). In the second experiment, seven patients with PAD and seven healthy controls performed low-intensity plantar flexion exercise (2.0 kg for 14 min). BP, heart rate (HR), and SmO 2 were measured continuously using near-infrared spectroscopy (NIRS). SmO 2 is the ratio of oxygenated hemoglobin to total hemoglobin, expressed as a percent. At fatigue, patients with PAD had a greater increase in mean arterial BP (18 ± 2 vs. vs. 10 ± 2 mmHg, P = 0.029) and HR (14 ± 2 vs. 6 ± 2 beats/min, P = 0.033) and a greater reduction in SmO 2 (-54 ± 10 vs. -12 ± 4%, P = 0.001). However, both groups had similar physiological responses to low-intensity, nonpainful plantar flexion exercise. These data suggest that patients with PAD have altered oxygen uptake and/or utilization during fatiguing exercise coincident with an augmented BP response. NEW & NOTEWORTHY In this laboratory study, patients with peripheral artery disease performed plantar flexion exercise in the supine posture until symptoms of claudication occurred. Relative to age- and sex-matched healthy subjects we found that patients had a higher blood pressure response, a higher heart rate response, and a greater reduction in skeletal muscle oxygenation as

  13. Measurement system for an in-vitro characterization of the biomechanics and hemodynamics of arterial bifurcations

    International Nuclear Information System (INIS)

    Suárez-Bagnasco, D; Balay, G; Negreira, C A; Cymberknop, L; Armentano, R L

    2013-01-01

    Arterial behaviour in-vivo is influenced, amongst other factors, by the interaction between blood flow and the arterial wall endothelium, and the biomechanical properties of the arterial wall. This interaction plays an important role in pathogenic mechanisms of cardiovascular diseases such as atherosclerosis and arteriosclerosis. To quantify these interactions both from biomechanical and hemodynamical standpoints, a complete characterization and modelling of the arterial wall, blood flow, shear wall and circumferential wall stresses are needed. The development of a new multi-parameter measurement system (distances, pressures, flows, velocity profiles, temperature, viscosity) for an in-vitro characterization of the biomechanics and hemodynamics in arterial bifurcations (specially in carotid bifurcations) is described. This set-up represents an improvement relative to previous set-ups developed by the group FCIEN-FMED and is presently under development. Main subsystems interactions and environment-system interactions were identified and compensated to improve system's performance. Several interesting problems related with signal acquisition using a variety of sensors and some experimental results are shown and briefly discussed. Experimental data allow construction of meshes and parameter estimation of the biomechanical properties of the arterial wall, as well as boundary conditions, all suitable to be employed in CFD and FSI numerical simulation.

  14. Contribution of the Arterial System and the Heart to Blood Pressure during Normal Aging - A Simulation Study

    NARCIS (Netherlands)

    Maksuti, Elira; Westerhof, Nico; Westerhof, Berend E.; Broomé, Michael; Stergiopulos, Nikos

    2016-01-01

    During aging, systolic blood pressure continuously increases over time, whereas diastolic pressure first increases and then slightly decreases after middle age. These pressure changes are usually explained by changes of the arterial system alone (increase in arterial stiffness and vascular

  15. Morning pressor surge, blood pressure variability, and arterial stiffness in essential hypertension.

    Science.gov (United States)

    Pucci, Giacomo; Battista, Francesca; Anastasio, Fabio; Schillaci, Giuseppe

    2017-02-01

    An excess morning blood pressure surge (MBPS) may portend an increased cardiovascular risk, but the mechanisms thereof have been little investigated. The link between MBPS, short-term blood pressure (BP) variability, and arterial stiffness has not been entirely defined. In 602 consecutive untreated hypertensive patients (48 ± 12 years, 61% men, office BP 149/93 ± 17/10 mmHg), we measured carotid-femoral pulse wave velocity (cf-PWV, SphygmoCor) and 24-h ambulatory BP. Using self-reported sleep and wake times, MBPS was defined as sleep-trough (ST-MBPS), prewaking, rising. Short-term BP variability was calculated as weighted 24-h SBP SD and average real variability of 24-h SBP (ARV), that is, average of absolute differences between consecutive SBP readings. ST-MBPS (r = 0.16, P < 0.001) and rising MBPS (r = 0.12, P = 0.003) showed a direct correlation with cf-PWV, whereas prewaking MBPS had no such relation (r = 0.06, P = 0.14). Only ST-MBPS was independently associated with cf-PWV (t = 1.96, P = 0.04) after adjustment for age, sex, height, office mean arterial pressure, heart rate, and renal function. This association was lost after further adjustment for weighted 24-h SBP SD (P = 0.13) or ARV (P = 0.24). ARV was a significant mediator of the relationship between ST-MBPS and cf-PWV (P = 0.003). In untreated hypertension, ST-MBPS has a direct relation with aortic stiffness, which is mediated by an increased ARV. The adverse effects of MBPS may be partly explained by its link with arterial stiffness, mediated by short-term SBP variability.

  16. Noninvasive arterial blood pressure waveforms in patients with continuous-flow left ventricular assist devices

    NARCIS (Netherlands)

    Martina, Jerson R.; Westerhof, Berend E.; de Jonge, Nicolaas; van Goudoever, Jeroen; Westers, Paul; Chamuleau, Steven; van Dijk, Diederik; Rodermans, Ben F. M.; de Mol, Bas A. J. M.; Lahpor, Jaap R.

    2014-01-01

    Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support.

  17. Pulsatility of Lenticulostriate Arteries Assessed by 7 Tesla Flow MRI-Measurement, Reproducibility, and Applicability to Aging Effect.

    Science.gov (United States)

    Schnerr, Roald S; Jansen, Jacobus F A; Uludag, Kamil; Hofman, Paul A M; Wildberger, Joachim E; van Oostenbrugge, Robert J; Backes, Walter H

    2017-01-01

    Characterization of flow properties in cerebral arteries with 1.5 and 3 Tesla MRI is usually limited to large cerebral arteries and difficult to evaluate in the small perforating arteries due to insufficient spatial resolution. In this study, we assessed the feasibility to measure blood flow waveforms in the small lenticulostriate arteries with 7 Tesla velocity-sensitive MRI. The middle cerebral artery was included as reference. Imaging was performed in five young and five old healthy volunteers. Flow was calculated by integrating time-varying velocity values over the vascular cross-section. MRI acquisitions were performed twice in each subject to determine reproducibility. From the flow waveforms, the pulsatility index and damping factor were deduced. Reproducibility values, in terms of the intraclass correlation coefficients, were found to be good to excellent. Measured pulsatility index of the lenticulostriate arteries significantly increased and damping factor significantly decreased with age. In conclusion, we demonstrate that blood flow through the lenticostriate arteries can be precisely measured using 7 Tesla MRI and reveal effects of arterial stiffness due to aging. These findings hold promise to provide relevant insights into the pathologies involving perforating cerebral arteries.

  18. Feasibility of arterial blood bypass using microcatheter in intraarterial thrombolysis for acute cerebral ischemic stroke

    International Nuclear Information System (INIS)

    Wang Wei; Li Cheng; Liu Zhensheng; Zhang Xinjiang; Zhou Longjiang; Yin Haiyan

    2010-01-01

    Objective: To assess the feasibility of arterial blood bypass using microcatheter in intraarterial thrombolysis for acute cerebral ischemic stroke. Methods: Six patients with acute cerebral infarction within 6 hours underwent intraarterial thrombolysis, in which arterial blood bypass was used. A 2.3 F microcatheter was advanced through the clot and two milliliters of contrast was injected beyond the clot that remained stagnant in the major branches. At this point, 20 ml of oxygenated blood from femoral artery was injected for 2 minutes through the microcatheter past the occluding clot. Then, conventional intraarterial thrombolysis, including fibrinolytic agents infusion and mechanical disruption, was performed. Intraarterial thrombolysis and oxygenated blood infusion alternated every 30 minutes. Results: Every patient received arterial blood bypass with average three times (from 1 to 5 times) in the process of the intraarterial thrombolysis, which cost (8.0 ± 3.2) min. Recanalization was achieved in all 6 patients, but minor subarachnoid hemorrhage developed in one patient. All the patients got favorable clinical outcome. The life conditions is excellent in 4 cases and good in 2 cases. Conclusions: Arterial blood bypass using microcatheter in intraarterial thrombolysis for acute cerebral ischemic stroke might be feasible, which did not interfere with conventional intraarterial thrombolysis and prolong the operation time significantly but could protect ischemic penumbra. (authors)

  19. Numerical investigation of MHD flow of blood and heat transfer in a stenosed arterial segment

    Energy Technology Data Exchange (ETDEWEB)

    Majee, Sreeparna; Shit, G.C., E-mail: gcs@math.jdvu.ac.in

    2017-02-15

    A numerical investigation of unsteady flow of blood and heat transfer has been performed with an aim to provide better understanding of blood flow through arteries under stenotic condition. The blood is treated as Newtonian fluid and the arterial wall is considered to be rigid having deposition of plaque in its lumen. The heat transfer characteristic has been analyzed by taking into consideration of the dissipation of energy due to applied magnetic field and the viscosity of blood. The vorticity-stream function formulation has been adopted to solve the problem using implicit finite difference method by developing well known Peaceman–Rachford Alternating Direction Implicit (ADI) scheme. The quantitative profile analysis of velocity, temperature and wall shear stress as well as Nusselt number is carried out over the entire arterial segment. The streamline and temperature contours have been plotted to understand the flow pattern in the diseased artery, which alters significantly in the downstream of the stenosis in the presence of magnetic field. Both the wall shear stress and Nusselt number increases with increasing magnetic field strength. However, wall shear stress decreases and Nusselt number enhances with Reynolds number. The results show that with an increase in the magnetic field strength upto 8 T, does not causes any damage to the arterial wall, but the study is significant for assessing temperature rise during hyperthermic treatment. - Highlights: • Fully numerical simulation is carried out for MHD blood flow in stenosed artery. • Dissipation of energy due to both magnetic field and blood viscosity is considered. • Strong Vortices are observed at the downstream of the stenosis in the arterial wall. • Flow reversal of blood is reduced by applying sufficient magnetic field strength. • Isothermal lines are strongly distorted in the presence of magnetic field strength.

  20. Investigation of spiral blood flow in a model of arterial stenosis

    OpenAIRE

    Paul, M.C.; Larman, A.

    2009-01-01

    The spiral component of blood flow has both beneficial and detrimental effects in human circulatory system [Stonebridge PA, Brophy CM. Spiral laminar flow in arteries? Lancet 1991; 338: 1360–1]. We investigate the effects of the spiral blood flow in a model of three-dimensional arterial stenosis with a 75% cross-sectional area reduction at the centre by means of computational fluid dynamics (CFD) techniques. The standard κ–ω model is employed for simulation of the blood flow for the...

  1. The pulmonary artery does not participate in the blood supply of lung cancer: experimental and DSA study

    International Nuclear Information System (INIS)

    Han Mingjun; Feng Gansheng; Yang Jianyong; Su Hongying; Zhao Zhongchun

    2000-01-01

    Objective: To investigate whether or not the pulmonary artery participates in the blood supply of lung cancer and its change of morphology and blood flow in lung cancer. Methods: Two different colors of silicone were injected separately into the bronchial and pulmonary arteries of 33 rat models with squamous cell carcinoma of lung. The origin of blood supply of lung cancer and the morphologic change of pulmonary artery were observed under a stereo-microscope. The DSA of bronchial and pulmonary artery were performed simultaneously in 28 patients with lung cancer. Results: The pulmonary branch of rat and patients were reduced,thinned and occluded in the affected lung. The pulmonary artery did not form tumor vessel,and pulmonary blood flow and perfusion were reduced or absent in the affected area. Conclusion: The pulmonary artery did not participate in the blood supply of lung cancer. It is unreasonable to perform transcatheter chemo-embolization for lung cancer via pulmonary artery

  2. Differential increases in blood flow velocity in the middle cerebral artery after tourniquet deflation during sevoflurane, isoflurane or propofol anaesthesia.

    Science.gov (United States)

    Kadoi, Y; Kawauchi, C H; Ide, M; Saito, S; Mizutani, A

    2009-07-01

    The purpose of this study was to examine the comparative effects of sevoflurane, isoflurane or propofol on cerebral blood flow velocity after tourniquet deflation during orthopaedic surgery. Thirty patients undergoing elective orthopaedic surgery were randomly divided into sevoflurane, isoflurane and propofol groups. Anaesthesia was maintained with sevoflurane, isoflurane or propofol infusion in 33% oxygen and 67% nitrous oxide, in whatever concentrations were necessary to keep bispectral index values between 45 and 50. Ventilatory rate or tidal volume was adjusted to target PaCO2 of 35 mmHg. A 2.0 MHz transcranial Doppler probe was attached to the patient's head at the temporal window and mean blood flow velocity in the middle cerebral artery was continuously measured. The extremity was exsanguinated with an Esmarch bandage and the pneumatic tourniquet was inflated to a pressure of 450 mmHg. Arterial blood pressure, heart rate, velocity in the middle cerebral artery and arterial blood gas analysis were measured every minute for 10 minutes after release of the tourniquet in all three groups. Velocity in the middle cerebral artery in the three groups increased for five minutes after tourniquet deflation. Because of the different cerebrovascular effects of the three agents, the degree of increase in flow velocity in the isoflurane group was greater than in the other two groups, the change in flow velocity in the propofol group being the lowest (at three minutes after deflation 40 +/- 7%, 32 +/- 6% and 28 +/- 10% in the isoflurane, sevoflurane and propofol groups respectively, P < 0.05).

  3. Dependency of cerebral blood flow upon mean arterial pressure in patients with acute bacterial meningitis

    DEFF Research Database (Denmark)

    Møller, Kirsten; Larsen, Fin Stolze; Qvist, Jesper

    2000-01-01

    Diseases, Copenhagen University Hospital, Denmark. PATIENTS: Sixteen adult patients with acute bacterial meningitis. INTERVENTION: Infusion of norepinephrine to increase MAP. MEASUREMENTS: During a rise in MAP induced by norepinephrine infusion, we measured relative changes in CBF by transcranial Doppler......OBJECTIVE: Patients with acute bacterial meningitis are often treated with sympathomimetics to maintain an adequate mean arterial pressure (MAP). We studied the influence of such therapy on cerebral blood flow (CBF). DESIGN: Prospective physiologic trial. SETTING: The Department of Infectious....... Autoregulation was classified as impaired if Vmean increased by >10% per 30 mm Hg increase in MAP and if no lower limit of autoregulation was identified by the computer program; otherwise, autoregulation was classified as preserved. MAIN RESULTS: Initially, Vmean increased from a median value of 46 cm/sec (range...

  4. Comparative study of Newtonian physiological blood flow through normal and stenosed carotid artery

    Science.gov (United States)

    Rahman, Mohammad Matiur; Hossain, Md. Anwar; Mamun, Khairuzzaman; Akhter, Most. Nasrin

    2017-06-01

    A numerical simulation is performed to investigate Newtonian physiological flows behavior on three dimensional idealized carotid artery (CA) and single stenosed (75% by area) carotid artery(SCA). The wall vessel is set as rigid during simulation. Bifurcated blood vessel are simulated by using three-dimensional flow analysis. Physiological and parabolic velocity profiles are set out to fix the conditions of inlet boundaries of artery. In other hand, physiological waveform is an important part of compilation and it is successfully done by utilization of Fourier series having sixteen harmonics. The investigation has a Reynolds number range of 94 to 1120. Low Reynolds number k — ω model has been used as governing equation. The investigation has been carried out to characterize the flow behavior of blood in two geometry, namely, (i) Normal carotid artery (CA) and (ii) Stenosed carotid artery (SCA). The Newtonian model has been used to study the physics of fluid. The findings of the two models are thoroughly compared in order to observe there behavioral sequence of flows. The numerical results were presented in terms of velocity, pressure, wall shear stress distributions and cross sectional velocities as well as the streamlines contour. Stenosis disturbs the normal pattern of blood flow through the artery as reduced area. At stenosis region velocity and peak Reynolds number rapidly increase and Reynolds number reach transitional and turbulent region. These flow fluctuation and turbulence have bad effect to the blood vessel which makes to accelerate the progress of stenosis.

  5. Arterial secondary blood flow patterns visualized with vector flow ultrasound

    DEFF Research Database (Denmark)

    Pedersen, Mads Møller; Pihl, Michael Johannes; Hansen, Jens Munk

    2011-01-01

    This study presents the first quantification and visualisation of secondary flow patterns with vector flow ultrasound. The first commercial implementation of the vector flow method Transverse Oscillation was used to obtain in-vivo, 2D vector fields in real-time. The hypothesis of this study...... was that the rotational direction is constant within each artery. Three data sets of 10 seconds were obtained from three main arteries in healthy volunteers. For each data set the rotational flow patterns were identified during the diastole. Each data set contains a 2D vector field over time and with the vector angles...

  6. Pressure drop and arterial compliance - Two arterial parameters in one measurement.

    Science.gov (United States)

    Rotman, Oren M; Zaretsky, Uri; Shitzer, Avraham; Einav, Shmuel

    2017-01-04

    Coronary artery pressure-drop and distensibility (compliance) are two major, seemingly unrelated, parameters in the cardiovascular clinical setting, which are indicative of coronary arteries patency and atherosclerosis severity. While pressure drop is related to flow, and therefore serves as a functional indicator of a stenosis severity, the arterial distensibility is indicative of the arterial stiffness, and hence the arterial wall composition. In the present study, we hypothesized that local pressure drops are dependent on the arterial distensibility, and hence can provide information on both indices. The clinical significance is that a single measurement of pressure drop could potentially provide both functional and bio-mechanical metrics of lesions, and thus assist in real-time decision making prior to stenting. The goal of the current study was to set the basis for understanding this relationship, and define the accuracy and sensitivity required from the pressure measurement system. The investigation was performed using numerical fluid-structure interaction (FSI) simulations, validated experimentally using our high accuracy differential pressure measurement system. Simplified silicone mock coronary arteries with zero to intermediate size stenoses were used, and various combinations of arterial distensibility, diameter, and flow rate were simulated. Results of hyperemic flow cases were also compared to fractional flow reserve (FFR). The results indicate the potential clinical superiority of a high accuracy pressure drop-based parameter over FFR, by: (i) being more lesion-specific, (ii) the possibility to circumvent the FFR dependency on pharmacologically-induced hyperemia, and, (iii) by providing both functional and biomechanical lesion-specific information. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Development of extrahepatic arterial blood supply to the liver during hepatic arterial infusion chemotherapy

    International Nuclear Information System (INIS)

    Seki, H.; Kimura, M.; Yoshimura, N.; Yamamoto, S.; Ozaki, T.; Sakai, K.

    1998-01-01

    The aim of this study was to evaluate the correlation of development of the collateral circulation to the liver during hepatic arterial infusion chemotherapy (HAIC) with the presence of hepatic tumours adjacent to the hepatic surface, and with pretreatment occlusion of aberrant hepatic arteries. In 102 patients with unresectable malignant hepatic tumours treated with HAIC using an implantable port system, development of collaterals to the liver was assessed with CT arteriography using the implantable port and pre- and postoperative angiography. Aberrant hepatic arteries, if present, were occluded prior to treatment for hepatic arterial redistribution. Collaterals to the liver were seen in 29 patients, who had 35 areas with collateral perfusion: 22 areas were in the right posterosuperior area, 6 in the left peripheral area and 7 in the right or left lobar area. Collaterals were revealed more frequently in patients with hepatic tumours adjacent to the hepatic surface than in those without hepatic tumours in peripheral areas in the liver (p < 0.0001). In addition, collaterals developed more frequently in patients with an aberrant hepatic arterial anatomy compared with those with conventional anatomy (p = 0.0007). Our results indicated that patients with hepatic tumours adjacent to the hepatic surface and with pretreatment occlusion of aberrant hepatic arteries had the potential to develop collaterals to the liver during HAIC. (orig.)

  8. Comparison of high-definition oscillometry -- a non-invasive technology for arterial blood pressure measurement -- with a direct invasive method using radio-telemetry in awake healthy cats.

    Science.gov (United States)

    Martel, Eric; Egner, Beate; Brown, Scott A; King, Jonathan N; Laveissiere, Arnaud; Champeroux, Pascal; Richard, Serge

    2013-12-01

    This study compared indirect blood pressure measurements using a non-invasive method, high-definition oscillometry (HDO), with direct measurements using a radio-telemetry device in awake cats. Paired measurements partitioned to five sub-ranges were collected in six cats using both methods. The results were analysed for assessment of correlation and agreement between the two methods, taking into account all pressure ranges, and with data separated in three sub-groups, low, normal and high ranges of systolic (SBP) and diastolic (DBP) blood pressure. SBP data displayed a mean correlation coefficient of 0.92 ± 0.02 that was reduced for low SBP. The agreement level evaluated from the whole data set was high and slightly reduced for low SBP values. The mean correlation coefficient of DBP was lower than for SBP (ie, 0.81 ± 0.02). The bias for DBP between the two methods was 22.3 ± 1.6 mmHg, suggesting that HDO produced lower values than telemetry. These results suggest that HDO met the validation criteria defined by the American College of Veterinary Internal Medicine consensus panel and provided a faithful measurement of SBP in conscious cats. For DBP, results suggest that HDO tended to underestimate DBP. This finding is clearly inconsistent with the good agreement reported in dogs, but is similar to outcomes achieved in marmosets and cynomolgus monkeys, suggesting that this is not related to HDO but is species related. The data support that the HDO is the first and only validated non-invasive blood pressure device and, as such, it is the only non-invasive reference technique that should be used in future validation studies.

  9. Palpatory method of measuring diastolic blood pressure

    Directory of Open Access Journals (Sweden)

    Dinesh Sahu

    2010-01-01

    Conclusion: The palpatory method would be very useful where frequent blood pressure measurement are being done manually like in wards, in busy OPD, patient on treadmill and also whenever stethoscope is not available. The blood pressure can be measured in noisy environment too.

  10. Arterial spin labeling blood flow magnetic resonance imaging for evaluation of renal injury.

    Science.gov (United States)

    Liu, Yupin P; Song, Rui; Liang, Chang hong; Chen, Xin; Liu, Bo

    2012-08-15

    A multitude of evidence suggests that iodinated contrast material causes nephrotoxicity; however, there have been no previous studies that use arterial spin labeling (ASL) blood flow functional magnetic resonance imaging (fMRI) to investigate the alterations in effective renal plasma flow between normointensive and hypertensive rats following injection of contrast media. We hypothesized that FAIR-SSFSE arterial spin labeling MRI may enable noninvasive and quantitative assessment of regional renal blood flow abnormalities and correlate with disease severity as assessed by histological methods. Renal blood flow (RBF) values of the cortex and medulla of rat kidneys were obtained from ASL images postprocessed at ADW4.3 workstation 0.3, 24, 48, and 72 h before and after injection of iodinated contrast media (6 ml/kg). The H&E method for morphometric measurements was used to confirm the MRI findings. The RBF values of the outer medulla were lower than those of the cortex and the inner medulla as reported previously. Iodinated contrast media treatment resulted in decreases in RBF in the outer medulla and cortex in spontaneously hypertensive rats (SHR), but only in the outer medulla in normotensive rats. The iodinated contrast agent significantly decreased the RBF value in the outer medulla and the cortex in SHR compared with normotensive rats after injection of the iodinated contrast media. Histological observations of kidney morphology were also consistent with ASL perfusion changes. These results demonstrate that the RBF value can reflect changes of renal perfusion in the cortex and medulla. ASL-MRI is a feasible and accurate method for evaluating nephrotoxic drugs-induced kidney damage.

  11. In vivo evaluation of femoral blood flow measured with magnetic resonance

    DEFF Research Database (Denmark)

    Henriksen, O; Ståhlberg, F; Thomsen, C

    1989-01-01

    , corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory...... arrest. The mean T2 of non-flowing blood was found to be 105 +/- 31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate......Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve...

  12. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm.

    Science.gov (United States)

    Goldstein, Lara Nicole; Wells, Mike; Sliwa, Karen

    2014-07-25

    Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer's guidelines. The arm and ankle BP measurements were compared. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (-13 mmHg, 95% confidence interval (CI) -28 - 1 mmHg and -5 mmHg, 95% CI -13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI -7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Ankle BP cannot be used as a substitute for arm BP in the ED.

  13. Cerebral oxygenation as measured by near-infrared spectroscopy in neonatal intensive care: correlation with arterial oxygenation.

    Science.gov (United States)

    Hunter, Carol Lu; Oei, Ju Lee; Lui, Kei; Schindler, Timothy

    2017-07-01

    To assess correlation between cerebral oxygenation (rScO 2 ), as measured by near-infrared spectroscopy (NIRS), and arterial oxygenation (PaO 2 ), as measured by arterial blood gases, in preterm neonates. Preterm neonates interpretation of NIRS values in neonatal intensive care, and further evaluation is needed to determine the applicability of NIRS to management of preterm infants. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  14. Alterations of Blood Flow Through Arteries Following Atherectomy and the Impact on Pressure Variation and Velocity.

    Science.gov (United States)

    Plourde, Brian D; Vallez, Lauren J; Sun, Biyuan; Nelson-Cheeseman, Brittany B; Abraham, John P; Staniloae, Cezar S

    2016-09-01

    Simulations were made of the pressure and velocity fields throughout an artery before and after removal of plaque using orbital atherectomy plus adjunctive balloon angioplasty or stenting. The calculations were carried out with an unsteady computational fluid dynamic solver that allows the fluid to naturally transition to turbulence. The results of the atherectomy procedure leads to an increased flow through the stenotic zone with a coincident decrease in pressure drop across the stenosis. The measured effect of atherectomy and adjunctive treatment showed decrease the systolic pressure drop by a factor of 2.3. Waveforms obtained from a measurements were input into a numerical simulation of blood flow through geometry obtained from medical imaging. From the numerical simulations, a detailed investigation of the sources of pressure loss was obtained. It is found that the major sources of pressure drop are related to the acceleration of blood through heavily occluded cross sections and the imperfect flow recovery downstream. This finding suggests that targeting only the most occluded parts of a stenosis would benefit the hemodynamics. The calculated change in systolic pressure drop through the lesion was a factor of 2.4, in excellent agreement with the measured improvement. The systolic and cardiac-cycle-average pressure results were compared with measurements made in a multi-patient study treated with orbital atherectomy and adjunctive treatment. The agreements between the measured and calculated systolic pressure drop before and after the treatment were within 3%. This excellent agreement adds further confidence to the results. This research demonstrates the use of orbital atherectomy to facilitate balloon expansion to restore blood flow and how pressure measurements can be utilized to optimize revascularization of occluded peripheral vessels.

  15. Renal embolic protection devices improve blood flow after stenting for atherosclerotic renal artery stenosis.

    Science.gov (United States)

    Paul, Timir K; Lee, John H; White, Christopher J

    2012-11-15

    We sought to measure angiographic renal frame counts (RFC), as a quantitative angiographic assessment of renal blood flow, to evaluate microvascular compromise due to atheroembolism associated with RAS. Atheroembolism associated with renal artery stenting (RAS) has been implicated as a cause for worsening renal function following successful intervention. Use of a distal embolic protection device (EPD) during RAS has been shown to be safe with debris capture in a high percentage of cases. However, objective benefit for renal function with EPD has been difficult to demonstrate. A control group of 30 consecutive patients (33 kidneys) who underwent RAS without EPD were compared with 33 consecutive patients (33 kidneys) who underwent RAS with EPD using RFC measurement. The prestent and poststent mean RFC for the control group was 30.4 ± 12.1 vs. 23.7 ± 9.9 (P = 0.002) and for the EPD group it was 42.6 ± 12.6 vs. 28.3 ± 9.2 (P renal blood flow, manifested by a greater reduction of the RFC (Δ RFC) 14.2 ± 15.2 vs. 6.7 ± 11.7 (P = 0.03) compared with the control group. The use of an EPD was associated with a much larger improvement in renal blood flow (lower RFC) following RAS. This suggests that EPD's may be effective in preventing renal atheroembolic injury and that a controlled trial measuring the impact of EPD's on renal blood flow following RAS should be performed. Copyright © 2012 Wiley Periodicals, Inc.

  16. Preanalytical Biases in the Measurement of Human Blood Sphingolipids

    Directory of Open Access Journals (Sweden)

    Robert Brunkhorst

    2018-05-01

    Full Text Available Dysregulation of blood sphingolipids is an emerging topic in clinical science. The objective of this study was to determine preanalytical biases that typically occur in clinical and translational studies and that influence measured blood sphingolipid levels. Therefore, we collected blood samples from four healthy male volunteers to investigate the effect of storage conditions (time, temperature, long-term storage, freeze–thaw cycles, blood drawing (venous or arterial sampling, prolonged venous compression, and sample preparation (centrifugation, freezing on sphingolipid levels measured by LC-MS/MS. Our data show that sphingosine 1-phosphate (S1P and sphinganine 1-phosphate (SA1P were upregulated in whole blood samples in a time- and temperature-dependent manner. Increased centrifugation at higher speeds led to lower amounts of S1P and SA1P. All other preanalytical biases did not significantly alter the amounts of S1P and SA1P. Further, in almost all settings, we did not detect differences in (dihydroceramide levels. In summary, besides time-, temperature-, and centrifugation-dependent changes in S1P and SA1P levels, sphingolipids in blood remained stable under practically relevant preanalytical conditions.

  17. Study on blood supply of lung metastasis with trans-pulmonary arterial lipiodol infusion

    International Nuclear Information System (INIS)

    Zhou Jianqin; Dong Weihua; Dong Weihua; Ouyang Chang; Chang Heng; Xiao Xiangsheng

    2008-01-01

    Objective: To evaluate the blood supply of pulmonary metastases using small volume of lipiodol through pulmonary arterial infusion. Methods: 10 cases of lung metastasis were enroled including the primary tumors of liver cancer (n=5), renal carcinoma (n=3), chordoma (n=1) and malignant neurofibroma (n=1). Plain CT scan was performed to exclude calcification or ossification within metastasis and then pulmonary arterial DSA was undertaken to evaluate tumor vessels or staining. After pulmonary arteriovenous fistula or other anomalous circulation was excluded by lobar arterial DSA, small volume of lipiodol was infused under fluoroscopy (0.5-1.5 ml for each lobar artery, total volume less than 3.0 ml). CT scan was immediately performed. Blood supply of the pulmonary metastases was assessed according to the accumulation of lipiodol on CT scans. Results: No cases but one experienced cough, expectoration, suffocating or dyspnea. No complication of cerebral or visceral embolism occurred. Totally 27 nodules were studied including 6 nodules with cloudy lipiodol accumulation and 6 nodules with tiny granules of lipiodol accumulation. No enlarged tumor vessel or tumor stain was observed within all 27 nodules on pulmonary arterial DSA. Conclusions: Pulmonary artery supplys only parts of pulmonary metastases, especially those sited at the peripheral region of the lung. Infusion of small volume of lipiodol through pulmonary artery is safe, and the increased density of lung field could return normal after several days. (authors)

  18. C-14-activity incorporation into the protein of fetal organs of guinea pigs with different maternal placental blood flow and fetal arterial O2-saturation

    International Nuclear Information System (INIS)

    Duenzl, B.

    1981-01-01

    In anaesthesised gravid guinea-pigs the dilate, end section of a placental radial artery was connected to the A.carotis via a flow meter and a throttle in order to measure and widely alter the maternal placental blood flow. Blood samples are taken from the fetal A.carotis, the fetal arterial O 2 -saturation and the Hb-content were determined. By altering the maternal placental blood circulation the fetal arterial O 2 -concentration can stabilised at various levels. In order to study the protein synthesis, under these conditions one infused 185 kBq C-14-leucine over a period of 3 hours into the jugular vein of the fetus. During infusion the radioactive concentrations in whole plasma and plasma water were measured. After the infusion the radioactive concentrations in the tissue fluid, the intracellular fluid and the acid-insoluble tissue fraction (protein) of the heart, kidenys, liver, the muscles of the upper end lower part of the body, the brain and the placenta were measured. The following deductions were drawn from the findings: The maternal placental blood flow vitally influences the activity incorporation per activity concentration in the plasma water. These findings agree with the hypotheses that the maternal blood circulation has an essential influence on the fetal proteins synthesis and that this influence can be attributed to the connection between placenta connection blood flow and oxygen saturation of fetal arterial blood. (orig.) [de

  19. Automatic noninvasive measurement of systolic blood pressure using photoplethysmography

    Directory of Open Access Journals (Sweden)

    Glik Zehava

    2009-10-01

    Full Text Available Abstract Background Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. Methods In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1 determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2 discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. Results Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. Conclusion The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.

  20. Results of ambulatory arterial blood pressure monitoring in children with obesity

    Directory of Open Access Journals (Sweden)

    Faruk Öktem

    2010-12-01

    Full Text Available Objectives: The relationship between obesity and essential hypertension is well known. In this study, we aimed to evaluate ambulatory arterial blood pressure monitoring of obese and non-obese children who had similar demographic characteristics.Materials and methods: Seventy one children and adolescents (n=39 obesity, n=32 controls were studied. Blood pressure of the children were measured by 24 hour ambulatory blood pressure monitoring device.Results: Obese children had significantly higher mean blood pressure values (systolic 121.9±11.7 mmHg, diastolic 70.2±5.3 mmHg than control subjects (systolic 109.3±6.7 mmHg, diastolic 65.1±4.6 mmHg, p0.05. Blood pressure load was found to be increased in obese children compared to the controls (%13.6±12.9 and %2.6±3.4, respectively; p<0.05. Serum total cholesterol and LDL-cholesterol levels of obese children (181.1±33.4 and 131.1±23.1mg/dl were significantly higher than those of the controls (134.3±11.1 and 103.3±14.2 mg/dl, p<0.05.Conclusions: Obesity in children and adolescents should not be regarded as variations of normality, but as abnormality with an extremely high risk for the development of hypertension and hyperlipidemia in adulthood.

  1. Measurement of digital blood pressure after local cooling

    DEFF Research Database (Denmark)

    Nielsen, S L; Lassen, N A

    1977-01-01

    A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between...... the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women...

  2. Numerical investigation of MHD flow of blood and heat transfer in a stenosed arterial segment

    Science.gov (United States)

    Majee, Sreeparna; Shit, G. C.

    2017-02-01

    A numerical investigation of unsteady flow of blood and heat transfer has been performed with an aim to provide better understanding of blood flow through arteries under stenotic condition. The blood is treated as Newtonian fluid and the arterial wall is considered to be rigid having deposition of plaque in its lumen. The heat transfer characteristic has been analyzed by taking into consideration of the dissipation of energy due to applied magnetic field and the viscosity of blood. The vorticity-stream function formulation has been adopted to solve the problem using implicit finite difference method by developing well known Peaceman-Rachford Alternating Direction Implicit (ADI) scheme. The quantitative profile analysis of velocity, temperature and wall shear stress as well as Nusselt number is carried out over the entire arterial segment. The streamline and temperature contours have been plotted to understand the flow pattern in the diseased artery, which alters significantly in the downstream of the stenosis in the presence of magnetic field. Both the wall shear stress and Nusselt number increases with increasing magnetic field strength. However, wall shear stress decreases and Nusselt number enhances with Reynolds number. The results show that with an increase in the magnetic field strength upto 8 T, does not causes any damage to the arterial wall, but the study is significant for assessing temperature rise during hyperthermic treatment.

  3. Relationship between vertebral artery blood flow in different head positions and vertigo.

    Science.gov (United States)

    Araz Server, Ela; Edizer, Deniz Tuna; Yiğit, Özgür; Yasak, Ahmet Görkem; Erdim, Çağrı

    2018-01-01

    To identify the vertebral artery blood flow in different head positions in patients with positional vertigo with no specific diagnosis. Patients with history of vestibular symptoms associated with changes in head position were enrolled into the study. Healthy volunteers were evaluated as control group. Doppler ultrasonography examination of the cervical segment of the vertebral arteries was performed under three different head positions: (i) supine position, (ii) head hyperextended and rotated to the right side and (iii) head hyperextended and rotated to the left side. In the study group, right and left vertebral artery blood flow was significantly lower in the ipsilateral hyperextended position compared to standard supine position (respectively p = .014; p = .001), but did not differ significantly when compared between the standard supine and contralateral hyperextended positions (respectively = .959; p = .669). In the control group, left and right vertebral artery blood flow did not differ significantly when the head was hyperextended to the right or left sides compared to standard supine position (p > .05). Our data demonstrated that the etiology of vestibular complaints in patients with undiagnosed positional vertigo might be related to impairment in vertebral artery blood flow according to head positions.

  4. The measurement of limb blood flow using technetium-labelled red blood cells

    International Nuclear Information System (INIS)

    Parkin, A; Robinson, P.J.; Wiggins, P.A.; Leveson, S.H.; Salter, M.C.P.; Matthews, I.F.; Ware, F.M.

    1986-01-01

    A method for measuring blood flow below the knee during reactive hyperaemia induced by 3 min of arterial occlusion has been developed. Subjects are positioned with lower limbs within the field of view of a gamma camera and pneumatic cuffs are placed below the knees to isolate the blood and induce a hyperaemic response. The remaining blood pool is labelled with 99 Tcsup(m)-labelled red cells. Blood flows have been derived from the initial gradients of time-activity curves and from equilibrium blood sampling. The technique has been validated using a tissue-equivalent leg phantom and peristaltic pump. The method has been applied to a small group of patients with peripheral vascular disease and to normal controls. The mean value (+-SD) of limb perfusion for normal controls was found to be 16.4+-3.0 ml/100 ml/min and for patients with intermittent claudication was 5.1+-2.6 ml/100 ml/min. Flow measurements are found to correlate with clinical findings and with symptoms. Reproducibility (established by repeated measurements) is high. The method is well tolerated even by patients suffering from rest pain. (author)

  5. Measurement of limb blood flow using technetium-labelled red blood cells

    Energy Technology Data Exchange (ETDEWEB)

    Parkin, A; Robinson, P.J.; Wiggins, P.A.; Leveson, S.H.; Salter, M.C.P.; Matthews, I.F.; Ware, F.M.

    1986-05-01

    A method for measuring blood flow below the knee during reactive hyperaemia induced by 3 min of arterial occlusion has been developed. Subjects are positioned with lower limbs within the field of view of a gamma camera and pneumatic cuffs are placed below the knees to isolate the blood and induce a hyperaemic response. The remaining blood pool is labelled with /sup 99/Tcsup(m)-labelled red cells. Blood flows have been derived from the initial gradients of time-activity curves and from equilibrium blood sampling. The technique has been validated using a tissue-equivalent leg phantom and peristaltic pump. The method has been applied to a small group of patients with peripheral vascular disease and to normal controls. The mean value (+-SD) of limb perfusion for normal controls was found to be 16.4 +- 3.0 ml/100 ml/min and for patients with intermittent claudication was 5.1 +- 2.6 ml/100 ml/min. Flow measurements are found to correlate with clinical findings and with symptoms. Reproducibility (established by repeated measurements) is high. The method is well tolerated even by patients suffering from rest pain.

  6. Dietary sodium bicarbonate, cool temperatures, and feed withdrawal: impact on arterial and venous blood-gas values in broilers.

    Science.gov (United States)

    Wideman, R F; Hooge, D M; Cummings, K R

    2003-04-01

    Sodium bicarbonate (NaHCO3) has been used successfully in mammals and birds to alleviate pulmonary hypertension. Experiment 1 was designed to provide measurements of arterial and venous blood-gas values from unanesthetized male broilers subjected to a cool temperature (16 degrees C) challenge and fed either a control diet or the same diet alkalinized by dilution with 1% NaHCO3. The incidences of pulmonary hypertension syndrome (PHS, ascites) for broilers fed the control or bicarbonate diets were 15.5 and 10.5%, respectively (P = 0.36, NS). Non-ascitic broilers fed the control diet were heavier than those fed the bicarbonate diet on d 49 (2,671 vs. 2,484 g, respectively); however, other comparisons failed to reveal diet-related differences in heart weight, pulse oximetry values, electrocardiogram amplitudes, or blood-gas values (P > 0.05). When the data were resorted into categories based on right:total ventricular weight ratios (RV:TV) indicative of normal (RV:TV or = 0.28) pulmonary arterial pressures, broilers with elevated RV:TV ratios had poorly oxygenated arterial blood that was more acidic, had high partial pressure of CO2 (PCO2), and had higher HCO3 concentrations when compared with broilers with normal RV:TV ratios. Experiment 2 was conducted to determine if metabolic variations associated with differences in feed intake or environmental temperature potentially could mask an impact of diet composition on blood-gas values. Male broilers maintained at thermoneutral temperature (24 degrees C) either received feed ad libitum or had the feed withdrawn > or = 12 h prior to blood sampling. Broilers fed ad libitum had lower venous saturation of hemoglobin with O2, higher venous PCO2, and higher arterial HCO3 concentrations than broilers subjected to feed withdrawal. Broilers in experiment 2 fed ad libitum and exposed to cool temperatures (16 degrees C) had lower arterial partial pressure of O2 and higher venous PCO2 than broilers fed ad libitum and maintained at 24

  7. Scintigraphic study of blood perfusion of the pulmonary artery in pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Certain, D.A.; Brolio, R.; Salomon, G.C.; Carvalho, N.; Barbosa, Z.L.M.

    1972-01-01

    Blood perfusion in the pulmonary artery is studied by pulmonary scintigraphy with macroaggregated albumin 131 I, in 74 cases of pulmonary tuberculosis. Results shown by scintigraphy are compared to those observed in roentgenography and also correlated with the extension and degree of the lesions, and with the presence of associated tuberculosis, considered capable of changing the scintigraphic picture. The reduction of blood flow in the pulmonary artery are observed in cases of infiltrative, fibrotic of caseous lesions, as well as in cases of minor lesions [pt

  8. Scintigraphic study of blood perfusion of the pulmonary artery in pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Certain, D A; Brolio, R; Salomon, G C [Sao Paulo Univ. (Brazil). Faculdade de Saude Publica; Carvalho, N [Sao Paulo Univ. (Brazil). Centro de Medicina Nuclear; Barbosa, Z L.M. [Associacao dos Sanatorios Populares de Campos do Jordao, Brazil

    1972-10-01

    Blood perfusion in the pulmonary artery is studied by pulmonary scintigraphy with macroaggregated albumin /sup 131/I, in 74 cases of pulmonary tuberculosis. Results shown by scintigraphy are compared to those observed in roentgenography and also correlated with the extension and degree of the lesions, and with the presence of associated tuberculosis, considered capable of changing the scintigraphic picture. The reduction of blood flow in the pulmonary artery are observed in cases of infiltrative, fibrotic of caseous lesions, as well as in cases of minor lesions.

  9. Determination of comprehensive arterial blood inflow in abdominal-pelvic organs: impact of respiration and posture on organ perfusion.

    Science.gov (United States)

    Osada, Takuya; Nagata, Hiroyasu; Murase, Norio; Kime, Ryotaro; Katsumura, Toshihito

    2011-02-01

    Arterial blood flow (BF) to all abdominal-pelvic organs (AP) shows potential for an indicator of comprehensive splanchnic organ circulation (reservoir of blood supply for redistribution) in cardiovascular disease, hepato-gastrointestinal disease or hemodynamic disorders. Our previous assessment of splanchnic hemodynamics, as magnitude of BFAP [measuring by subtracting BF in both femoral arteries (FAs) from the upper abdominal aorta (Ao) above the celiac trunk] using Doppler ultrasound, was reported as the relationship between Ao and FAs, day-to-day variability and response to exercise. For accurate determination of BFAP, it is important to consider the various factors that potentially influence BFAP. However, little information exists regarding the influence of respiration (interplay between inspiration and expiration) and posture on BFAP. Ten healthy males were evaluated in sitting/supine positions following a 12 hr fast. Magnitude of BFAP was determined as measurement of Ao and FAs hemodynamics (blood velocity and vessel diameter) using pulsed Doppler with spectral analysis during spontaneous 4-sec inspiration/4-sec expiration phases. BF/blood velocity in the Ao and FAs showed significant lower in inspiration than expiration. BFAP showed a significant (Ppressure during breathing (thoracic-abdominal movement) is possibly reflecting transient changes in blood velocity in the Ao and FAs. Respiratory effects should be taken into account for evaluation of BFAP.

  10. PX-18 Protects Human Saphenous Vein Endothelial Cells under Arterial Blood Pressure.

    Science.gov (United States)

    Kupreishvili, Koba; Stooker, Wim; Emmens, Reindert W; Vonk, Alexander B A; Sipkens, Jessica A; van Dijk, Annemieke; Eijsman, Leon; Quax, Paul H; van Hinsbergh, Victor W M; Krijnen, Paul A J; Niessen, Hans W M

    2017-07-01

    Arterial blood pressure-induced shear stress causes endothelial cell apoptosis and inflammation in vein grafts after coronary artery bypass grafting. As the inflammatory protein type IIA secretory phospholipase A 2 (sPLA 2 -IIA) has been shown to progress atherosclerosis, we hypothesized a role for sPLA 2 -IIA herein. The effects of PX-18, an inhibitor of both sPLA 2 -IIA and apoptosis, on residual endothelium and the presence of sPLA 2 -IIA were studied in human saphenous vein segments (n = 6) perfused at arterial blood pressure with autologous blood for 6 hrs. The presence of PX-18 in the perfusion blood induced a significant 20% reduction in endothelial cell loss compared to veins perfused without PX18, coinciding with significantly reduced sPLA 2 -IIA levels in the media of the vein graft wall. In addition, PX-18 significantly attenuated caspase-3 activation in human umbilical vein endothelial cells subjected to shear stress via mechanical stretch independent of sPLA 2 -IIA. In conclusion, PX-18 protects saphenous vein endothelial cells from arterial blood pressure-induced death, possibly also independent of sPLA 2 -IIA inhibition. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Intraosseous blood samples for point-of-care analysis: agreement between intraosseous and arterial analyses.

    Science.gov (United States)

    Jousi, Milla; Saikko, Simo; Nurmi, Jouni

    2017-09-11

    Point-of-care (POC) testing is highly useful when treating critically ill patients. In case of difficult vascular access, the intraosseous (IO) route is commonly used, and blood is aspirated to confirm the correct position of the IO-needle. Thus, IO blood samples could be easily accessed for POC analyses in emergency situations. The aim of this study was to determine whether IO values agree sufficiently with arterial values to be used for clinical decision making. Two samples of IO blood were drawn from 31 healthy volunteers and compared with arterial samples. The samples were analysed for sodium, potassium, ionized calcium, glucose, haemoglobin, haematocrit, pH, blood gases, base excess, bicarbonate, and lactate using the i-STAT® POC device. Agreement and reliability were estimated by using the Bland-Altman method and intraclass correlation coefficient calculations. Good agreement was evident between the IO and arterial samples for pH, glucose, and lactate. Potassium levels were clearly higher in the IO samples than those from arterial blood. Base excess and bicarbonate were slightly higher, and sodium and ionised calcium values were slightly lower, in the IO samples compared with the arterial values. The blood gases in the IO samples were between arterial and venous values. Haemoglobin and haematocrit showed remarkable variation in agreement. POC diagnostics of IO blood can be a useful tool to guide treatment in critical emergency care. Seeking out the reversible causes of cardiac arrest or assessing the severity of shock are examples of situations in which obtaining vascular access and blood samples can be difficult, though information about the electrolytes, acid-base balance, and lactate could guide clinical decision making. The analysis of IO samples should though be limited to situations in which no other option is available, and the results should be interpreted with caution, because there is not yet enough scientific evidence regarding the agreement of IO

  12. Reduction of Blood Pressure Following After Renal Artery Adventitia Stripping During Total Nephroureterectomy: Potential Effect of Renal Sympathetic Denervation.

    Science.gov (United States)

    Okamura, Keisuke; Satou, Shunsuke; Setojima, Keita; Shono, Shinjiro; Miyajima, Shigero; Ishii, Tatsu; Shirai, Kazuyuki; Urata, Hidenori

    2018-05-16

    BACKGROUND Catheter-based renal sympathetic denervation has been reported to be effective for treatment resistance hypertension in Australia and Europe. However, in the blinded SYMPLICITY HTN-3 trial, renal denervation did not achieve a significant decrease in blood pressure (BP) in comparison to sham controls. There have been various discussions on the factors that influenced this result. CASE REPORT Two men on antihypertensive therapy underwent unilateral radical nephroureterectomy for cancer of the renal pelvis. When the renal artery adventitia was stripped and cauterized just before renal artery ligation, the measured BP of the 2 men increased after stripping adventitia and decreased gradually after cauterization of the renal artery. This was presumably due to removal of renal artery sympathetic nerves, similar to the mechanism of catheter-based renal sympathetic denervation, although anesthesia, fluid infusion, and/or mesenteric traction may have had an influence. CONCLUSIONS A similar strategy involving thoracolumbar sympathectomy was reported about 50 years ago. The clinically significant blood pressure reduction in these patients suggests renal denervation is effective.

  13. Weaning mechanical ventilation after off-pump coronary artery bypass graft procedures directed by noninvasive gas measurements.

    Science.gov (United States)

    Chakravarthy, Murali; Narayan, Sandeep; Govindarajan, Raghav; Jawali, Vivek; Rajeev, Subramanyam

    2010-06-01

    Partial pressure of carbon dioxide and oxygen were transcutaneously measured in adults after off-pump coronary artery bypass (OPCAB) surgery. The clinical use of such measurements and interchangeability with arterial blood gas measurements for weaning patients from postoperative mechanical ventilation were assessed. This was a prospective observational study. Tertiary referral heart hospital. Postoperative OPCAB surgical patients. Transcutaneous oxygen and carbon dioxide measurements. In this prospective observational study, 32 consecutive adult patients in a tertiary care medical center underwent OPCAB surgery. Noninvasive measurement of respiratory gases was performed during the postoperative period and compared with arterial blood gases. The investigator was blinded to the reports of arterial blood gas studies and weaned patients using a "weaning protocol" based on transcutaneous gas measurement. The number of patients successfully weaned based on transcutaneous measurements and the number of times the weaning process was held up were noted. A total of 212 samples (pairs of arterial and transcutaneous values of oxygen and carbon dioxide) were obtained from 32 patients. Bland-Altman plots and mountain plots were used to analyze the interchangeability of the data. Twenty-five (79%) of the patients were weaned from the ventilator based on transcutaneous gas measurements alone. Transcutaneous carbon dioxide measurements were found to be interchangeable with arterial carbon dioxide during 96% of measurements, versus 79% for oxygen measurements. More than three fourths of the patients were weaned from mechanical ventilation and extubated based on transcutaneous gas values alone after OPCAB surgery. The noninvasive transcutaneous carbon dioxide measurement can be used as a surrogate for arterial carbon dioxide measurement to manage postoperative OPCAB patients. Copyright 2010 Elsevier Inc. All rights reserved.

  14. Phantom with pulsatile arteries to investigate the influence of blood vessel depth on pulse oximeter signal strength.

    Science.gov (United States)

    Stuban, Norbert; Niwayama, Masatsugu; Santha, Hunor

    2012-01-01

    This paper describes a three-layer head phantom with artificial pulsating arteries at five different depths (1.2 mm, 3.7 mm, 6.8 mm, 9.6 mm and 11.8 mm). The structure enables formation of spatially and temporally varying tissue properties similar to those of living tissues. In our experiment, pressure pulses were generated in the arteries by an electronically controlled pump. The physical and optical parameters of the layers and the liquid in the artificial arteries were similar to those of real tissues and blood. The amplitude of the pulsating component of the light returning from the phantom tissues was measured at each artery depth mentioned above. The build-up of the in-house-developed pulse oximeter used for performing the measurements and the physical layout of the measuring head are described. The radiant flux generated by the LED on the measuring head was measured to be 1.8 mW at 910 nm. The backscattered radiant flux was measured, and found to be 0.46 nW (0.26 ppm), 0.55 nW (0.31 ppm), and 0.18 nW (0.10 ppm) for the 1.2 mm, 3.7 mm and 6.8 mm arteries, respectively. In the case of the 9.6 mm and 11.8 mm arteries, useful measurement data were not obtained owing to weak signals. We simulated the phantom with the arteries at the above-mentioned five depths and at two additional ones (2.5 mm and 5.3 mm in depth) using the Monte Carlo method. The measurement results were verified by the simulation results. We concluded that in case of 11 mm source-detector separation the arteries at a depth of about 2.5 mm generate the strongest pulse oximeter signal level in a tissue system comprising three layers of thicknesses: 1.5 mm (skin), 5.0 mm (skull), and >50 mm (brain).

  15. Phantom with Pulsatile Arteries to Investigate the Influence of Blood Vessel Depth on Pulse Oximeter Signal Strength

    Directory of Open Access Journals (Sweden)

    Hunor Santha

    2012-01-01

    Full Text Available This paper describes a three-layer head phantom with artificial pulsating arteries at five different depths (1.2 mm, 3.7 mm, 6.8 mm, 9.6 mm and 11.8 mm. The structure enables formation of spatially and temporally varying tissue properties similar to those of living tissues. In our experiment, pressure pulses were generated in the arteries by an electronically controlled pump. The physical and optical parameters of the layers and the liquid in the artificial arteries were similar to those of real tissues and blood. The amplitude of the pulsating component of the light returning from the phantom tissues was measured at each artery depth mentioned above. The build-up of the in-house-developed pulse oximeter used for performing the measurements and the physical layout of the measuring head are described. The radiant flux generated by the LED on the measuring head was measured to be 1.8 mW at 910 nm. The backscattered radiant flux was measured, and found to be 0.46 nW (0.26 ppm, 0.55 nW (0.31 ppm, and 0.18 nW (0.10 ppm for the 1.2 mm, 3.7 mm and 6.8 mm arteries, respectively. In the case of the 9.6 mm and 11.8 mm arteries, useful measurement data were not obtained owing to weak signals. We simulated the phantom with the arteries at the above-mentioned five depths and at two additional ones (2.5 mm and 5.3 mm in depth using the Monte Carlo method. The measurement results were verified by the simulation results. We concluded that in case of 11 mm source-detector separation the arteries at a depth of about 2.5 mm generate the strongest pulse oximeter signal level in a tissue system comprising three layers of thicknesses: 1.5 mm (skin, 5.0 mm (skull, and > 50 mm (brain.

  16. Queixa de vertigem e hipertensão arterial Vertigo complaint and blood hypertension

    Directory of Open Access Journals (Sweden)

    Luciana Lozza de Moraes Marchiori

    2007-03-01

    Full Text Available OBJETIVO: investigar a presença de queixa de vertigem em pacientes de meia idade com hipertensão arterial. MÉTODOS: estudo do tipo prospectivo, transversal. Composto por 154 indivíduos de ambos os gêneros com idade de 45 a 64 anos. A hipertensão foi verificada por meio de medição da pressão arterial e de questionário sistematizado sobre hipertensão e uso de medicamentos para pressão arterial. A queixa de vertigem foi verificada por meio de anamnese audiológica. RESULTADOS: pode-se verificar que existe associação significante entre hipertensão arterial e queixa de vertigem. CONCLUSÃO: os resultados da presente pesquisa, por meio da constatação da associação entre hipertensão arterial e queixa de vertigem, servirão de base a profissionais da área de saúde que estão envolvidos com sintomas provenientes da hipertensão arterial.PURPOSE: to investigate the presence of vertigo complaint in middle-aged hypertension patients. METHODS: a transversal study. Composed by 154 patients of both genders, aged from 45 to 64 years, included in the research after sample estimation. Hypertension was verified through blood pressure readings and by a systematized questionnaire about hypertension and the use of medication for blood pressure. Vertigo was assessed through audiological anamneses. RESULTS: there is a significant association between blood hypertension and vertigo. CONCLUSION: the results in this research, through evidence of association between blood hypertension and vertigo complaint, can be a base for health professionals concerned with alterations caused by blood hypertension.

  17. In vivo evaluation of femoral blood flow measured with magnetic resonance

    International Nuclear Information System (INIS)

    Henriksen, O.; Staahlberg, F.; Thomsen, C.; Moegelvang, J.; Persson, B.; Lund Univ.

    1989-01-01

    Quantitative measurements of blood flow based on magnetic resonance imaging (MRI) using conventional multiple spin echo sequences were evaluated in vivo in healthy young volunteers. Blood flow was measured using MRI in the femoral vein. The initial slope of the multiple spin echo decay curve, corrected for the T2 decay of non-flowing blood was used to calculate the blood flow. As a reference, the blood flow in the femoral artery was measured simultaneously with an invasive indicator dilution technique. T2 of non-flowing blood was measured in vivo in popliteal veins during regional circulatory arrest. The mean T2 of non-flowing blood was found to be 105±31 ms. The femoral blood flow ranged between 0 and 643 ml/min measured with MRI and between 280 and 531 ml/min measured by the indicator dilution technique. There was thus poor agreement between the two methods. The results indicate that in vivo blood flow measurements made with MRI based on wash-out effects, commonly used in multiple spin echo imaging, do not give reliable absolute values for blood flow in the femoral artery or vein. (orig.)

  18. Blood pressure reactivity to psychological stress and coronary calcification in the Coronary Artery Risk Development in Young Adults Study.

    Science.gov (United States)

    Matthews, Karen A; Zhu, Sha; Tucker, Diane C; Whooley, Mary A

    2006-03-01

    A longstanding hypothesis is that individuals who exhibit large increases in blood pressure during psychological stress are at risk for atherosclerosis. We tested whether blood pressure changes during psychological stress predict subsequent coronary calcification (CaC) in young healthy adults. We evaluated 2816 healthy black and white women, 20 to 35 years of age, from the Coronary Artery Risk Development in Young Adults Study, who were not using medication for hypertension or diabetes in 1987-1988. Participants completed video game and star tracing tasks while their blood pressure was recorded. Thirteen years later (2000-2001), they completed computed tomography measures of CaC. Overall 9.3% (261 of 2816) had CaC present at follow-up. Each 10 mm Hg change in systolic blood pressure during the video game was associated with a 24% increased odds of having CaC at follow-up (unadjusted odds ratio, 1.24; 95% CI, 1.06 to 1.46; P=0.008). This association persisted after adjustment for age, race, sex, education, smoking, alcohol, family history of myocardial infarction, smoking, daily alcohol consumption, body mass index, and resting or baseline blood pressure (odds ratio, 1.31; 95% CI, 1.08 to 1.58; P=0.006). Blood pressure changes during the star tracing task were not associated with subsequent CaC. Blood pressure changes during a video game predicted the presence of CaC 13 years later. To our knowledge, this is the first study that reports blood pressure reactivity to a stressor being related to calcification in the coronary arteries. Blood pressure reactivity may provide useful prognostic information about future risk beyond standard risk factors.

  19. Arterial pressure measurement: Is the envelope curve of the oscillometric method influenced by arterial stiffness?

    International Nuclear Information System (INIS)

    Gelido, G; Angiletta, S; Pujalte, A; Quiroga, P; Cornes, P; Craiem, D

    2007-01-01

    Measurement of peripheral arterial pressure using the oscillometric method is commonly used by professionals as well as by patients in their homes. This non invasive automatic method is fast, efficient and the required equipment is affordable with a low cost. The measurement method consists of obtaining parameters from a calibrated decreasing curve that is modulated by heart beats witch appear when arterial pressure reaches the cuff pressure. Diastolic, mean and systolic pressures are obtained calculating particular instants from the heart beats envelope curve. In this article we analyze the envelope of this amplified curve to find out if its morphology is related to arterial stiffness in patients. We found, in 33 volunteers, that the envelope waveform width correlates to systolic pressure (r=0.4, p<0.05), to pulse pressure (r=0.6, p<0.05) and to pulse pressure normalized to systolic pressure (r=0.6, p<0.05). We believe that the morphology of the heart beats envelope curve obtained with the oscillometric method for peripheral pressure measurement depends on arterial stiffness and can be used to enhance pressure measurements

  20. Vasoactive enzymes and blood flow responses to passive and active exercise in peripheral arterial disease

    DEFF Research Database (Denmark)

    Walker, Meegan A.; Høier, Birgitte; Walker, Philip J.

    2016-01-01

    Background: Peripheral arterial disease (PAD) is characterised by impaired leg blood flow, which contributes to claudication and reduced exercise capacity. This study investigated to what extent vasoactive enzymes might contribute to altered blood flow in PAD (Fontaine stage II). Methods: We...... compared femoral artery blood flow during reactive hyperaemia, leg-extension exercise and passive leg movement, and determined the level of vasoactive enzymes in skeletal muscle samples from the vastus lateralis in PAD (n = 10, 68.5 ± 6.5 years) and healthy controls (CON, n = 9, 62.1 ± 12.3 years). Leg...... than CON (1.04 ± 0.19 vs 0.50 ± 0.06 AU, P = 0.02), with no differences for other enzymes. Leg blood flow during exercise was correlated with prostacyclin synthase (P = 0.001). Conclusion: Elevated NADPH oxidase indicates that oxidative stress may be a primary cause of low nitric oxide availability...

  1. Radionuclide scanning in a study of the pulmonary blood flow with the open arterial canal

    International Nuclear Information System (INIS)

    Rizaev, M.N.; Gulyamov, D.S.; Khodzhibekov, M.Kh.; Anvarov, M.A.

    1980-01-01

    Characteristic features of the distribution of the arterial pulmonary blood flow have been studied in 32 patients with the open arterial flow by lung scanning with albumin macroaggregate and 131 I. Research was conducted using the gamma-Ochamber ''Fo Gamma LFV'' and the scanner ''Magnaskaner 500I''. Disordered distribution of the pulmonary blood flow expressed in its unilateral decrease was detected in 17 patients (52.9%). A higher frequency of pulmonary hypertension was noted in these patients versus those with a relatively normal distribution of the pulmonary blood flow. A severe course of the disease was observed in high pulmonary hypertension combined with sharp suppression of the blood flow in one of the lungs or with signs of the shift from the right to the left side

  2. Comparison of arterial and venous blood biomarker levels in chronic obstructive pulmonary disease [v1; ref status: indexed, http://f1000r.es/9x

    Directory of Open Access Journals (Sweden)

    Emer Kelly

    2013-04-01

    Full Text Available Purpose: The development of novel biomarkers is an unmet need in chronic obstructive pulmonary disease (COPD. Arterial blood comes directly from the lung and venous blood drains capillary beds of the organ or tissue supplied. We hypothesized that there would be a difference in levels of the biomarkers metalloproteinase 9 (MMP-9, vascular endothelial growth factor A (VEGF-A and interleukin 6 (IL-6 in arterial compared with venous blood.  Methods: Radial artery and brachial vein blood samples were taken simultaneously in each of 12 patients with COPD and seven controls with normal lung function. Circulating immunoreactive MMP-9, VEGF-A and IL-6 levels in serum were measured using quantitative enzyme-linked immunosorbent assays. Results were compared using a Student’s paired t test. The study was powered to determine whether significant differences in cytokine levels were present between paired arterial and venous blood samples.   Results: In the 12 patients with COPD, four were female, and age ranged 53-85 years, mean age 69 years. Three patients in the control group were female, with age range 46-84 years, mean age 64.7 years. In the COPD group, three patients had mild, five moderate and four severe COPD. No significant difference was found between arterial and venous levels of MMP-9, VEGF-A or IL-6.  Conclusions: In this pilot study, levels of the measured biomarkers in arterial compared with venous blood in both COPD patients and healthy controls did not differ. This suggests that as we continue to chase the elusive biomarker in COPD as a potential tool to measure disease activity, we should focus on venous blood for this purpose.

  3. Femoral artery pressure measurement to predict the outcome of arterial surgery in patients with multilevel disease

    DEFF Research Database (Denmark)

    Faris, I; Tønnesen, K H; Agerskov, K

    1982-01-01

    Direct measurement of the femoral artery pressure before operation has been used to predict the postoperative change in ankle and toe pressure in 102 limbs (83 patients) that underwent aortoiliac surgery for the treatment of atherosclerotic occlusion or stenosis affecting both the aortoiliac...... and femoral artery segments. Rest pain or gangrene was present in 74 limbs. In 26 other limbs simultaneous aortoiliac and femoral artery reconstructions were performed. The changes in both toe and ankle pressures could be confidently predicted from the preoperative data. A predicted toe pressure of lower than...... 25 mm Hg was associated with a high probability that amputation would be required. The chances of an amputation were less than 3% if a toe pressure higher than 40 mm Hg was predicted. If the predicted ankle pressure index was lower than 0.56, there was a 90% chance that intermittent claudication...

  4. Does dairy food intake predict arterial stiffness and blood pressure in men?: Evidence from the Caerphilly Prospective Study.

    Science.gov (United States)

    Livingstone, Katherine M; Lovegrove, Julie A; Cockcroft, John R; Elwood, Peter C; Pickering, Janet E; Givens, D Ian

    2013-01-01

    Arterial stiffness is an independent predictor of cardiovascular disease events and mortality, and like blood pressure, may be influenced by dairy food intake. Few studies have investigated the effects of consumption of these foods on prospective measures of arterial stiffness. The present analysis aimed to investigate the prospective relationship between milk, cheese, cream, and butter consumption and aortic pulse wave velocity, augmentation index, systolic and diastolic blood pressure, as well as cross-sectional relationships between these foods and systolic and diastolic blood pressure and metabolic markers using data from the Caerphilly Prospective Study. Included in this cohort were 2512 men, aged 45 to 59 years, who were followed up at 5-year intervals for a mean of 22.8 years (number follow-up 787). Augmentation index was 1.8% lower in subjects in the highest quartiles of dairy product intake compared with the lowest (P trend=0.021), whereas in the highest group of milk consumption systolic blood pressure was 10.4 mm Hg lower (P trend=0.033) than in nonmilk consumers after a 22.8-year follow-up. Cross-sectional analyses indicated that across increasing quartiles of butter intake, insulin (P trend=0.011), triacylglycerol (P trend=0.023), total cholesterol (P trend=0.002), and diastolic blood pressure (P trend=0.027) were higher. Across increasing groups of milk intake and quartiles of dairy product intake, glucose (P trend=0.032) and triglyceride concentrations (P trend=0.031) were lower, respectively. The present results confirm that consumption of milk predicts prospective blood pressure, whereas dairy product consumption, excluding butter, is not detrimental to arterial stiffness and metabolic markers. Further research is needed to better understand the mechanisms that underpin these relationships.

  5. Cerebral blood flow measurement in cerebrovascular occlusive diseases

    International Nuclear Information System (INIS)

    Yanagihara, T.; Wahner, H.W.

    1984-01-01

    In order to evaluate cerebral blood flow (CBF) patterns among individual patients with increased statistical confidence, CBF measurements were carried out using the 133Xe-inhalation method and external head detectors. F1 values representing gray matter flow from 3 to 6 head detectors were averaged to form 16 different regions for each cerebral hemisphere. Normative values were obtained from 46 healthy volunteers, and data from individual regions were analyzed for absolute blood flow rates (ml/100g/min), for concordance between right and left hemispheres and as percent of mean hemispheric flow. CBF measurements were then carried out among 37 patients with cerebrovascular occlusive diseases, and results were compared with normative values. A high incidence of abnormal flows were detected among symptomatic patients with intracranial arterial stenosis or occlusion and those with extracranial internal carotid artery occlusion. By using the above method for data analysis, it was possible to delineate hypoperfused areas among these patients. Even though the 133Xe-inhalation method has inherent limitations, this is a practical and safe method for measurement of CBF which can provide reliable information useful for management of patients with cerebrovascular occlusive diseases, particularly when the results are presented with statistical confidence

  6. Arterial Blood Pressure Induces Transient C4b-Binding Protein in Human Saphenous Vein Grafts.

    Science.gov (United States)

    Kupreishvili, Koba; Meischl, Christof; Vonk, Alexander B A; Stooker, Wim; Eijsman, Leon; Blom, Anna M; Quax, Paul H A; van Hinsbergh, Victor W M; Niessen, Hans W M; Krijnen, Paul A J

    2017-05-01

    Complement is an important mediator in arterial blood pressure-induced vein graft failure. Previously, we noted activation of cell protective mechanisms in human saphenous veins too. Here we have analyzed whether C4b-binding protein (C4bp), an endogenous complement inhibitor, is present in the vein wall. Human saphenous vein segments obtained from patients undergoing coronary artery bypass grafting (n = 55) were perfused in vitro at arterial blood pressure with either autologous blood for 1, 2, 4, or 6 hr or with autologous blood supplemented with reactive oxygen species scavenger N-acetylcysteine. The segments were subsequently analyzed quantitatively for presence of C4bp and complement activation product C3d using immunohistochemistry. Perfusion induced deposition of C3d and C4bp within the media of the vessel wall, which increased reproducibly and significantly over a period of 4 hr up to 3.8% for C3d and 81% for C4bp of the total vessel area. Remarkably after 6 hr of perfusion, the C3d-positive area decreased significantly to 1.3% and the C4bp-positive area to 19% of the total area of the vein. The areas positive for both C4bp and C3d were increased in the presence of N-acetylcysteine. Exposure to arterial blood pressure leads to a transient presence of C4bp in the vein wall. This may be part of a cell-protective mechanism to counteract arterial blood pressure-induced cellular stress and inflammation in grafted veins. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Effects of exercise training on calf muscle oxygen extraction and blood flow in patients with peripheral artery disease.

    Science.gov (United States)

    Baker, Wesley B; Li, Zhe; Schenkel, Steven S; Chandra, Malavika; Busch, David R; Englund, Erin K; Schmitz, Kathryn H; Yodh, Arjun G; Floyd, Thomas F; Mohler, Emile R

    2017-12-01

    We employed near-infrared optical techniques, diffuse correlation spectroscopy (DCS), and frequency-domain near-infrared spectroscopy (FD-NIRS) to test the hypothesis that supervised exercise training increases skeletal muscle microvascular blood flow and oxygen extraction in patients with peripheral artery disease (PAD) who experience claudication. PAD patients ( n = 64) were randomly assigned to exercise and control groups. Patients in the exercise group received 3 mo of supervised exercise training. Calf muscle blood flow and oxygen extraction were optically monitored before, during, and after performance of a graded treadmill protocol at baseline and at 3 mo in both groups. Additionally, measurements of the ankle-brachial index (ABI) and peak walking time (PWT) to maximal claudication were made during each patient visit. Supervised exercise training was found to increase the maximal calf muscle blood flow and oxygen extraction levels during treadmill exercise by 29% (13%, 50%) and 8% (1%, 12%), respectively [ P group population were significantly higher than corresponding changes in the control group ( P training also increased PWT by 49% (18%, 101%) ( P = 0.01). However, within statistical error, the ABI, resting calf muscle blood flow and oxygen extraction, and the recovery half-time for hemoglobin\\myoglobin desaturation following cessation of maximal exercise were not altered by exercise training. The concurrent monitoring of both blood flow and oxygen extraction with the hybrid DCS/FD-NIRS instrument revealed enhanced muscle oxidative metabolism during physical activity from exercise training, which could be an underlying mechanism for the observed improvement in PWT. NEW & NOTEWORTHY We report on noninvasive optical measurements of skeletal muscle blood flow and oxygen extraction dynamics before/during/after treadmill exercise in peripheral artery disease patients who experience claudication. The measurements tracked the effects of a 3-mo supervised

  8. Mini-cardiopulmonary bypass impact on blood conservation strategy in coronary artery bypass grafting.

    Science.gov (United States)

    Abdel Aal, Mohamed; ElNahal, Nezar; Bakir, Bakir Moustafa; Fouda, Mohamed

    2011-04-01

    Cardiopulmonary bypass (CPB) using a closed circuit system with minimal priming volume can be a solution to ameliorate adverse effects of CPB. We hypothesize that the use of mini-bypass in routine coronary artery bypass grafting (CABG) reduces homologous blood product use and postoperative bleeding. The study is designed to determine the differences in blood loss and transfusion requirements associated with a minimized CPB circuit vs. a standard bypass circuit. From February 2009 to August 2009, 80 patients were prospectively randomized to undergo elective CABG. Group A included 40 patients who had the minimized bypass circuit (Medtronic Resting Heart Circuit). Group B had an equal number of patients who had the standard CPB circuit (Stockert III, SEC.BM). Laboratory parameters for hemoglobin, hematocrit and platelet count were measured at baseline after initiation of CPB and after bypass. Blood usage was controlled by study-specific protocol (transfusion for hemoglobin platelets (1.95±2.95 units vs. 3.23±2.85), and postoperative drainage in 24 hours (531.62±220.12 ml vs. 729±294.9 ml, P<0.05). The hematocrit was 33±5% in group A, and 27±1% in group B. There was statistical differences seen in the mean hemoglobin level which was 10.19±0.65 g/dl in group A, and 9.4±0.68 g/dl in group B. There was statistical difference in the duration of ventilation, length of ICU stay. The requirement of inotropic support was lower in group A. The adoption of mini-bypass significantly reduces morbidity including donor blood usage and postoperative bleeding in routine CABG patients.

  9. [Effect of hemodilution with 10% hydroxyethyl starch solution (MW 200,000/9.5) on the flow properties of blood, arterial blood gases and conjunctival oxygen partial pressure in patients with cerebral infarct].

    Science.gov (United States)

    Staedt, U; Hütt, M; Herrmann, B; Seufzer, U; Leweling, H

    1989-06-01

    Hemorheological parameters, arterial blood gases and conjunctival oxygen tension were measured in 15 patients with acute ischemic stroke and compared with values obtained in an age matched reference group. Since the conjunctival capillary bed is perfused by the ophthalmic artery, it reflects the oxygen delivery to the areas supplied by the internal carotid artery. Measurements of conjunctival oxygen tension are simple and safe. Patients with acute ischemic stroke showed a lowered conjunctival oxygen tension; this holds true especially to the ipsilateral side, i.e. the side where the attack occurred, and to a lesser extent to the other side. By contrast, the ratio of arterial/conjunctival pO2 was disturbed only on the ipsilateral side. Furthermore, these patients had pathologically elevated values for red cell aggregation, whole blood and plasma viscosity. After infusing 500 ml 10% middle-molecular-weight hydroxyethyl starch (10% HAES-steril) and phlebotomy (250 ml) blood fluidity was normalized, although the hematokrit was only slightly reduced. Arterial pO2 improved slightly while pCO2 remained unchanged. Conjunctival oxygen tension improved by 30% on the ipsilateral and by 10% on the contralateral side, the ipsilateral values always remaining significantly lower. The ratio conjunctival/arterial pO2 raised only on the ipsilateral side where it was below the reference range before hemodilution. In addition to the well known improvement of blood fluidity and augmentation of cerebral blood flow following hemodilution in patients with acute ischemic stroke, there seems to be an increase in oxygen supply in the territories of both internal carotid arteries, especially on the ipsilateral side as indicated by the values of conjunctival oxygen tension and the ratio of conjunctival to arterial pO2.

  10. Hemoglobin, hematocrit, and changes in cerebral blood flow : The Second Manifestations of ARTerial disease-Magnetic Resonance study

    NARCIS (Netherlands)

    van der Veen, Pieternella H.; Muller, Majon; Vincken, Koen L.; Westerink, Jan; Mali, Willem P. T. M.; van der Graaf, Yolanda; Geerlings, Mirjam I.; Doevendans, PAFM

    Hemoglobin and hematocrit are important determinants of blood viscosity and arterial oxygen content and may therefore influence cerebral blood flow (CBF). We examined cross-sectional and prospective associations of hemoglobin and hematocrit with CBF in 569 patients with manifest arterial disease

  11. ANGIOGRAPHIC ANATOMY OF THE MAJOR ABDOMINAL ARTERIAL BLOOD SUPPLY IN THE DOG.

    Science.gov (United States)

    Culp, William T N; Mayhew, Philipp D; Pascoe, Peter J; Zwingenberger, Allison

    2015-01-01

    Vascular-based interventional radiology (IR) procedures are being more regularly performed in veterinary patients for both diagnostic and therapeutic purposes. A complete description of the fluoroscopic arterial anatomy of the canine abdominal cavity has not been published. This information is essential for performance of IR procedures to allow for improved preparation before and during a particular procedure. The primary purpose of this study was to provide a fluoroscopic description of the vascular branching from the abdominal aorta in a ventro-dorsal projection with a secondary goal of producing pictorial reference images of the major abdominal arterial blood vessels. Five healthy female hound type dogs were enrolled and underwent fluoroscopic arteriography. During fluoroscopy, both nonselective and selective arteriography were performed. The nonselective arteriograms were obtained in the aorta at four locations: cranial to the celiac artery, cranial to the renal arteries, cranial to the caudal mesenteric artery, and cranial to the branching of the external iliac arteries. Selective arteriography was conducted by performing injections into the following arteries: celiac, splenic, common hepatic, cranial mesenteric, left and right renal, and caudal mesenteric. Fluoroscopic arteriography allowed for excellent characterization of the aortic ostia and the location of the lower order vascular branches. Future evaluation of vascular-based treatment options will likely increase as the understanding of the normal and pathologic anatomy improves. © 2015 American College of Veterinary Radiology.

  12. Opposing effects of particle pollution, ozone, and ambient temperature on arterial blood pressure.

    Science.gov (United States)

    Hoffmann, Barbara; Luttmann-Gibson, Heike; Cohen, Allison; Zanobetti, Antonella; de Souza, Celine; Foley, Christopher; Suh, Helen H; Coull, Brent A; Schwartz, Joel; Mittleman, Murray; Stone, Peter; Horton, Edward; Gold, Diane R

    2012-02-01

    Diabetes increases the risk of hypertension and orthostatic hypotension and raises the risk of cardiovascular death during heat waves and high pollution episodes. We examined whether short-term exposures to air pollution (fine particles, ozone) and heat resulted in perturbation of arterial blood pressure (BP) in persons with type 2 diabetes mellitus (T2DM). We conducted a panel study in 70 subjects with T2DM, measuring BP by automated oscillometric sphygmomanometer and pulse wave analysis every 2 weeks on up to five occasions (355 repeated measures). Hourly central site measurements of fine particles, ozone, and meteorology were conducted. We applied linear mixed models with random participant intercepts to investigate the association of fine particles, ozone, and ambient temperature with systolic, diastolic, and mean arterial BP in a multipollutant model, controlling for season, meteorological variables, and subject characteristics. An interquartile increase in ambient fine particle mass [particulate matter (PM) with an aerodynamic diameter of ≤ 2.5 μm (PM2.5)] and in the traffic component black carbon in the previous 5 days (3.54 and 0.25 μg/m3, respectively) predicted increases of 1.4 mmHg [95% confidence interval (CI): 0.0, 2.9 mmHg] and 2.2 mmHg (95% CI: 0.4, 4.0 mmHg) in systolic BP (SBP) at the population geometric mean, respectively. In contrast, an interquartile increase in the 5-day mean of ozone (13.3 ppb) was associated with a 5.2 mmHg (95% CI: -8.6, -1.8 mmHg) decrease in SBP. Higher temperatures were associated with a marginal decrease in BP. In subjects with T2DM, PM was associated with increased BP, and ozone was associated with decreased BP. These effects may be clinically important in patients with already compromised autoregulatory function.

  13. Renal artery blood flow assessed by video dilution technique before and after percutaneous transluminal angioplasty

    International Nuclear Information System (INIS)

    Lantz, B.M.T.; Link, D.P.; Lewis, E.L.; Foerster, J.M.; Lee, G.

    1981-01-01

    Successful percutaneous transluminal angioplasty was performed in 3 cases of renal artery stenosis where the effect upon renal blood flow was quantified by video dilution technique. This technique adds important information to pressure gradients and renin assays obtained during the dilatation procedure. (Auth.)

  14. Unilateral renal artery stenosis and hypertension. II. Angiographic findings correlated with blood pressure response after surgery

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I; Bergentz, S E; Ericsson, B F; Dymling, J F; Hansson, B G; Hoekfelt, B [Department of Diagnostic Radiography, Surgery and Endocrinology, Malmoe Allmaenna Sjukhus, Malmoe, Sweden

    1979-01-01

    The findings at preoperative nephroanigiography of 42 hypertensive patients with unilateral renal artery stenosis or occlusion were correlated with the blood pressure response following surgery and also with the preoperative renal vein renin activity ratio. A stenosis reducing luminal area by at least 90 per cent (or occlusion) and the presence of collateral circulation are considered to be highly suggestive of renovascular hypertension.

  15. A 2D nonlinear multiring model for blood flow in large elastic arteries

    Science.gov (United States)

    Ghigo, Arthur R.; Fullana, Jose-Maria; Lagrée, Pierre-Yves

    2017-12-01

    In this paper, we propose a two-dimensional nonlinear ;multiring; model to compute blood flow in axisymmetric elastic arteries. This model is designed to overcome the numerical difficulties of three-dimensional fluid-structure interaction simulations of blood flow without using the over-simplifications necessary to obtain one-dimensional blood flow models. This multiring model is derived by integrating over concentric rings of fluid the simplified long-wave Navier-Stokes equations coupled to an elastic model of the arterial wall. The resulting system of balance laws provides a unified framework in which both the motion of the fluid and the displacement of the wall are dealt with simultaneously. The mathematical structure of the multiring model allows us to use a finite volume method that guarantees the conservation of mass and the positivity of the numerical solution and can deal with nonlinear flows and large deformations of the arterial wall. We show that the finite volume numerical solution of the multiring model provides at a reasonable computational cost an asymptotically valid description of blood flow velocity profiles and other averaged quantities (wall shear stress, flow rate, ...) in large elastic and quasi-rigid arteries. In particular, we validate the multiring model against well-known solutions such as the Womersley or the Poiseuille solutions as well as against steady boundary layer solutions in quasi-rigid constricted and expanded tubes.

  16. Reciprocal Influence of Slow Waves Extracted in Intracranial Pressure, Arterial Pressure and Cerebral Blood Velocity Signals

    National Research Council Canada - National Science Library

    Cervenansky, F

    2001-01-01

    ...), and arterial blood pressure (ABP). To clarify the links, we compared two frequency methods based on coherence function to estimate the influence of ICP, ABP, and CBV on couples, respectively CBV-ABP, ICP-CBV and ICP-ABP, of slow waves...

  17. Differences in perioperative femoral and radial arterial blood pressure in neonates and infants undergoing cardiac surgery requiring cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Hwa Jin Cho

    Full Text Available Abstract Objective: Several reports claim that blood pressure (BP in the radial artery may underestimate the accurate BP in critically ill patients. Here, the authors evaluated differences in mean blood pressure (MBP between the radial and femoral artery during pediatric cardiac surgery to determine the effectiveness of femoral arterial BP monitoring. Method: The medical records of children under 1 year of age who underwent open-heart surgery between 2007 and 2013 were retrospectively reviewed. Radial and femoral BP were measured simultaneously, and the differences between these values were analyzed at various times: after catheter insertion, after the initiation of cardiopulmonary bypass (CPB-on, after aortic cross clamping (ACC, after the release of ACC, after weaning from CPB, at arrival in the intensive care unit (ICU, and every 6 h during the first day in the ICU. Results: A total of 121 patients who underwent open-heart surgery met the inclusion criteria. During the intraoperative period, from the beginning to the end of CPB, radial MBPs were significantly lower than femoral MBPs at each time-point measured (p 60 min, odds ratio: 7.47 was a risk factor for lower radial pressure. However, discrepancies between these two values disappeared after arrival in the ICU. There was no incidence of ischemic complications associated with the catheterization of both arteries. Conclusion: The authors suggest that femoral arterial pressure monitoring can be safely performed, even in neonates, and provides more accurate BP values during CPB-on periods, and immediately after weaning from CPB, especially when CPB time was greater than 60 min.

  18. The stability of arterial blood gases during transportation of patients using the RespirTech PRO.

    Science.gov (United States)

    Romano, M; Raabe, O G; Walby, W; Albertson, T E

    2000-05-01

    The transportation of critically ill patients requiring mechanical ventilation is recognized as a high-risk and expensive procedure. Approaches have included using manual bag-type valve resuscitators and expensive portable transport ventilators. This study evaluated the effectiveness of the inexpensive portable RespirTech PRO (RTP) gas-powered automatic resuscitator during intrahospital transport of critically ill mechanically ventilated patients. Twenty medical intensive care patients on stable mechanical ventilator settings had arterial blood gas and vital sign determination before routine transport out of the intensive care unit (ICU). Repeat measurements were made during transport approximately 30 minutes after being placed on the RTP portable pressure-cycled automatic resuscitator using an FiO2 of 100%. During use of the RTP for transport, there were no statistically significant variations observed in mean arterial blood pressure [82 +/- 11 SD (range 65 to 112) mm Hg before transport versus 85 +/- 14 SD (range 59 to 110) mm Hg during transport], heart rate [94 +/- 16 SD (range 74 to 127) beats/min) before versus 96 +/- 17 SD (range 69 to 132) beats/min during], arterial pH [7.41 +/- 0.07 SD (range 7.31 to 7.58) before versus 7.42 +/- 0.05 SD (range 7.37 to 7.52) during], and PaCO2 [43 +/- 10 SD (range 26 to 65) mm Hg before versus 43 +/- 10 SD (range 27 to 61 mm Hg) during]. Because the FiO2 before transport was 63 +/- 26 SD (range 30% to 100%) versus 100% during transport using the RTP, the mean PaO2 was significantly increased from 124 +/- 86 SD (range 57 to 367) mm Hg before transport to 297 +/- 168 SD (range 65 to 537) mm Hg during (P< .001). No transportation associated clinical adverse events were noted. Several previous investigations have shown that portable ventilators are safe and effective in intrahospital transport of mechanically ventilated patients. This study showed that the portable pressure-cycled RTP also allows safe transportation of

  19. Simple technique for measuring relative renal blood flow

    International Nuclear Information System (INIS)

    Shames, D.M.; Korobkin, M.

    1976-01-01

    To determine whether externally monitored early renal uptake of 131 I-hippurate is proportional to renal blood flow, the renal uptake of 131 -hippurate at 1 to 2 min after injection was compared with the renal accumulation of radioactive carbonized microspheres in dogs. A renal artery catheter equipped with a balloon was used to decrease renal blood flow unilaterally. One minute after the intravenous injection of 100 μCi of 131 I-hippurate, about 1 μCi of either 85 Sr- or 95 Nb-labeled carbon microspheres was injected into the left ventricle. Radioactivity was measured over both kidneys. The total radioactivity within each kidney region of interest was corrected for background and integrated over the 1 to 2 min interval after injection. Thirteen measurements of relative renal blood flow were made for seven dogs. The dogs were then killed and both kidneys were excised and counted for the radioactivity of the microspheres. The 1 to 2-min relative renal uptake of 131 I-hippurate correlated well with relative microsphere uptake, suggesting that relative renal blood flow can be simply determined from the external measurements of renal uptake of 131 I-hippurate

  20. [Evaluation of the arterial blood flow parameters in the eye of myopic patients].

    Science.gov (United States)

    Mrugacz, Małgorzata; Bryl, Anna

    2013-04-01

    Myopia is a common refractive defect. Has a good vision from near and deterioration of vision with increasing distance. The main reason for its occurrence is too long axis of the eyeball. The consequence of elongation of the eyeball is the development of degenerative changes in the retina. Despite much research has failed to clearly identify the causes of degenerative changes in those short-sighted. The aim of the study was to evaluate the maximum and minimum speed in arterial blood vessels of the eye in people with myopia. The study included 70 patients (138 eyes), 53 women and 17 men, aged from 18 to 79 years, with myopia of -0.25 to -18.0 Dsph and length of the eyeball from 22.61 to 33.36 mm. Depending on the kind and the degree of the progress of degenerative changes, patients were divided in 4 groups: I - without degenerative changes on the fundus (n=32; K-23, M-9); II- with the short-sighted sickle (n=20; K-14, M-6); Ill - with the structure thinned down of the retina, accompanying the short-sighted sickle (n = 8; K-6, M-2); IV - with extensive choroidal-retina disappearances in the fundus (n = 10; K-7, M-3). In all individuals enrolled underwent Color Doppler ultrasound with apparatus SSA 770A Toshiba Aplio with linear probe frequency 12 MHz, judging maximum (Vmax) and minimum (Vmin) speed in the arteries of the eye: ophthalmic artery (OA), central retinal artery (CRA) and short posterior ciliary arteries (SPCA) located on the nasal and temporal side of the optic disc. The results were statistically analyzed. No statistically significant relationship between the nature of degenerative changes of the eye, and blood velocity in the OA. There was a increase in Vmax and Vmin blood in OA in Group IV, but these changes were not statistically significant. Statistically significant correlation was observed while in the CRA. With a decrease in Vmax and Vmin of blood flowing through a vessel exacerbation of retinal degeneration. Vmax and Vmin changes in the blood did

  1. Joint segmentation of lumen and outer wall from femoral artery MR images: Towards 3D imaging measurements of peripheral arterial disease.

    Science.gov (United States)

    Ukwatta, Eranga; Yuan, Jing; Qiu, Wu; Rajchl, Martin; Chiu, Bernard; Fenster, Aaron

    2015-12-01

    Three-dimensional (3D) measurements of peripheral arterial disease (PAD) plaque burden extracted from fast black-blood magnetic resonance (MR) images have shown to be more predictive of clinical outcomes than PAD stenosis measurements. To this end, accurate segmentation of the femoral artery lumen and outer wall is required for generating volumetric measurements of PAD plaque burden. Here, we propose a semi-automated algorithm to jointly segment the femoral artery lumen and outer wall surfaces from 3D black-blood MR images, which are reoriented and reconstructed along the medial axis of the femoral artery to obtain improved spatial coherence between slices of the long, thin femoral artery and to reduce computation time. The developed segmentation algorithm enforces two priors in a global optimization manner: the spatial consistency between the adjacent 2D slices and the anatomical region order between the femoral artery lumen and outer wall surfaces. The formulated combinatorial optimization problem for segmentation is solved globally and exactly by means of convex relaxation using a coupled continuous max-flow (CCMF) model, which is a dual formulation to the convex relaxed optimization problem. In addition, the CCMF model directly derives an efficient duality-based algorithm based on the modern multiplier augmented optimization scheme, which has been implemented on a GPU for fast computation. The computed segmentations from the developed algorithm were compared to manual delineations from experts using 20 black-blood MR images. The developed algorithm yielded both high accuracy (Dice similarity coefficients ≥ 87% for both the lumen and outer wall surfaces) and high reproducibility (intra-class correlation coefficient of 0.95 for generating vessel wall area), while outperforming the state-of-the-art method in terms of computational time by a factor of ≈ 20. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. The feasibility of measuring renal blood flow using transesophageal echocardiography in patients undergoing cardiac surgery.

    Science.gov (United States)

    Yang, Ping-Liang; Wong, David T; Dai, Shuang-Bo; Song, Hai-Bo; Ye, Ling; Liu, Jin; Liu, Bin

    2009-05-01

    There is no reliable method to monitor renal blood flow intraoperatively. In this study, we evaluated the feasibility and reproducibility of left renal blood flow measurements using transesophageal echocardiography during cardiac surgery. In this prospective noninterventional study, left renal blood flow was measured with transesophageal echocardiography during three time points (pre-, intra-, and postcardiopulmonary bypass) in 60 patients undergoing cardiac surgery. Sonograms from 6 subjects were interpreted by 2 blinded independent assessors at the time of acquisition and 6 mo later. Interobserver and intraobserver reproducibility were quantified by calculating variability and intraclass correlation coefficients. Patients with Doppler angles of >30 degrees (20 of 60 subjects) were eliminated from renal blood flow measurements. Left renal blood flow was successfully measured and analyzed in 36 of 60 (60%) subjects. Both interobserver and intraobserver variability were renal blood flow measurements were good to excellent (intraclass correlation coefficients 0.604-0.999). Left renal arterial luminal diameter for the pre, intra, and postcardiopulmonary bypass phases, ranged from 3.8 to 4.1 mm, renal arterial velocity from 25 to 35 cm/s, and left renal blood flow from 192 to 299 mL/min. In patients undergoing cardiac surgery, it was feasible in 60% of the subjects to measure left renal blood flow using intraoperative transesophageal echocardiography. The interobserver and intraobserver reproducibility of renal blood flow measurements was good to excellent.

  3. A comparison of total amount of blood needed in patients taking autologous or homologous blood transfusion in coronary artery bypass grafting a clinical randomized case control trial

    International Nuclear Information System (INIS)

    Akhlagh, S.H.; Chohedri, A.H.; Bazojoo, A.; Nemati, M.H.

    2007-01-01

    The aim of this clinical case-control trial was to compare the total amount of blood needed in patients taking autologous or homologous blood transfusion in coronary artery bypass grafting (CABG) surgery. Sixty patients scheduled for CABG were randomly allocated to ANH (Acute Normovulemic Hemodynamic) group (A group) or control group (B group). Hematocrit before operation and 24 hours after the operation were checked. The amount of the total blood needed in each group was measured at the end of the operation. There was no significant difference between the two groups as regards post operational hematocrit. The mean total blood infused to the control and ANH group was 2010 ml and 1815 ml respectively. However there was significant difference between the two groups as regards the total amount of the blood needed during operation. Our randomized, double blinded case control study demonstrated that autologous blood, beside carrying lower risks for hemolytic and nonhemolytic transfusion reactions decrease the total amount of blood needed for CABG. However larger studies with more patients are needed to confirm the results. (author)

  4. Evaluation of the Effects of Sildenafil Citrate (Viagra) on Vertebral Artery Blood Flow in Patients with Vertebro-Basilar Insufficiency

    International Nuclear Information System (INIS)

    Bozgeyik, Zulkif; Berilgen, Sait; Ozdemir, Huseyin; Ogur, Erkin; Tekatas, Aslan

    2008-01-01

    To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). The study included 21 patients with VBI (aged 31-76; mean 61.0 ± 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm 2 to 10.80 cm 2 at 45 minutes and 10.81 cm 2 at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs

  5. Evaluation of the effects of sildenafil citrate (viagra) on vertebral artery blood flow in patients with vertebro-basilar insufficiency.

    Science.gov (United States)

    Bozgeyik, Zulkif; Berilgen, Sait; Ozdemir, Huseyin; Tekatas, Aslan; Ogur, Erkin

    2008-01-01

    To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). The study included 21 patients with VBI (aged 31-76; mean 61.0 +/- 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm(2) to 10.80 cm(2) at 45 minutes and 10.81 cm(2) at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs.

  6. Evaluation of the Effects of Sildenafil Citrate (Viagra) on Vertebral Artery Blood Flow in Patients with Vertebro-Basilar Insufficiency

    Energy Technology Data Exchange (ETDEWEB)

    Bozgeyik, Zulkif; Berilgen, Sait; Ozdemir, Huseyin; Ogur, Erkin [Firat University School of Medicine, Elazig(Turkmenistan); Tekatas, Aslan [Elazig Government Hospital, Elazig (Turkmenistan)

    2008-12-15

    To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). The study included 21 patients with VBI (aged 31-76; mean 61.0 +- 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm{sup 2} to 10.80 cm{sup 2} at 45 minutes and 10.81 cm{sup 2} at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs

  7. Measurement of bone blood flow in sheep

    International Nuclear Information System (INIS)

    Rosenthal, M.S.; Lehner, C.E.; Pearson, D.W.; Kanikula, T.; Adler, G.; Venci, R.; Lanphier, E.H.; DeLuca, P.M. Jr.

    1984-01-01

    Bone blood flow in sheep tibia has been estimated via the measurement of the perfusion limited clearance of 41 Ar from the bone mineral matrix following fast neutron activation of 44 Ca. Tibia blood flows were estimated for the intact sheep, and after the installation of an intramedullary pressure tap to elevate bone marrow pressure by saline infusion. The results indicate that normal blood flow in the tibia is in the range of 1.1 to 3.7 ml/100ml-min in the intact animal and at normal marrow pressure. With an elevated intramedullary pressure of approximately 100 mmHg, the bone blood flow measured varied around 0.5 to 1.1 ml/100ml-min. 12 refs., 5 figs., 1 tab

  8. Directly measuring spinal cord blood flow and spinal cord perfusion pressure via the collateral network: correlations with changes in systemic blood pressure.

    Science.gov (United States)

    Kise, Yuya; Kuniyoshi, Yukio; Inafuku, Hitoshi; Nagano, Takaaki; Hirayasu, Tsuneo; Yamashiro, Satoshi

    2015-01-01

    During thoracoabdominal surgery in which segmental arteries are sacrificed over a large area, blood supply routes from collateral networks have received attention as a means of avoiding spinal cord injury. The aim of this study was to investigate spinal cord blood supply through a collateral network by directly measuring spinal cord blood flow and spinal cord perfusion pressure experimentally. In beagle dogs (n = 8), the thoracoabdominal aorta and segmental arteries L1-L7 were exposed, and a temporary bypass was created for distal perfusion. Next, a laser blood flow meter was placed on the spinal dura mater in the L5 region to measure the spinal cord blood flow. The following were measured simultaneously when the direct blood supply from segmental arteries L2-L7 to the spinal cord was stopped: mean systemic blood pressure, spinal cord perfusion pressure (blood pressure within the aortic clamp site), and spinal cord blood flow supplied via the collateral network. These variables were then investigated for evidence of correlations. Positive correlations were observed between mean systemic blood pressure and spinal cord blood flow during interruption of segmental artery flow both with (r = 0.844, P flow with and without distal perfusion (r = 0.803, P network from outside the interrupted segmental arteries, and high systemic blood pressure (∼1.33-fold higher) was needed to obtain the preclamping spinal cord blood flow, whereas 1.68-fold higher systemic blood pressure was needed when distal perfusion was halted. Spinal cord blood flow is positively correlated with mean systemic blood pressure and spinal cord perfusion pressure under spinal cord ischemia caused by clamping a wide range of segmental arteries. In open and endovascular thoracic and thoracoabdominal surgery, elevating mean systemic blood pressure is a simple and effective means of increasing spinal cord blood flow, and measuring spinal cord perfusion pressure seems to be useful for monitoring

  9. The development and optimisation of 3D black-blood R2* mapping of the carotid artery wall.

    Science.gov (United States)

    Yuan, Jianmin; Graves, Martin J; Patterson, Andrew J; Priest, Andrew N; Ruetten, Pascal P R; Usman, Ammara; Gillard, Jonathan H

    2017-12-01

    To develop and optimise a 3D black-blood R 2 * mapping sequence for imaging the carotid artery wall, using optimal blood suppression and k-space view ordering. Two different blood suppression preparation methods were used; Delay Alternating with Nutation for Tailored Excitation (DANTE) and improved Motion Sensitive Driven Equilibrium (iMSDE) were each combined with a three-dimensional (3D) multi-echo Fast Spoiled GRadient echo (ME-FSPGR) readout. Three different k-space view-order designs: Radial Fan-beam Encoding Ordering (RFEO), Distance-Determined Encoding Ordering (DDEO) and Centric Phase Encoding Order (CPEO) were investigated. The sequences were evaluated through Bloch simulation and in a cohort of twenty volunteers. The vessel wall Signal-to-Noise Ratio (SNR), Contrast-to-Noise Ratio (CNR) and R 2 *, and the sternocleidomastoid muscle R 2 * were measured and compared. Different numbers of acquisitions-per-shot (APS) were evaluated to further optimise the effectiveness of blood suppression. All sequences resulted in comparable R 2 * measurements to a conventional, i.e. non-blood suppressed sequence in the sternocleidomastoid muscle of the volunteers. Both Bloch simulations and volunteer data showed that DANTE has a higher signal intensity and results in a higher image SNR than iMSDE. Blood suppression efficiency was not significantly different when using different k-space view orders. Smaller APS achieved better blood suppression. The use of blood-suppression preparation methods does not affect the measurement of R 2 *. DANTE prepared ME-FSPGR sequence with a small number of acquisitions-per-shot can provide high quality black-blood R 2 * measurements of the carotid vessel wall. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. The effect of ultrasound on arterial blood flow: 1. Steady fully developed flow

    International Nuclear Information System (INIS)

    Bestman, A.R.

    1990-12-01

    The paper models the effects of ultrasound heating of the tissues and the resultant perturbation on blood flow in the arteries and veins. It is assumed that the blood vessel is rigid and the undisturbed flow is fully developed. Acoustical perturbation on this Poiseuille flow, for the general three-dimensional flow with heat transfer in an infinitely long pipe is considered. Closed form analytical solutions are obtained to the problem. It is discovered that the effects of the ultrasound heating are concentrated at the walls of the blood vessels. (author). 4 refs

  11. Unsteady Blood Flow with Nanoparticles Through Stenosed Arteries in the Presence of Periodic Body Acceleration

    Science.gov (United States)

    Fatin Jamil, Dzuliana; Roslan, Rozaini; Abdulhameed, Mohammed; Che-Him, Norziha; Sufahani, Suliadi; Mohamad, Mahathir; Ghazali Kamardan, Muhamad

    2018-04-01

    The effects of nanoparticles such as Fe 3O4,TiO2, and Cu on blood flow inside a stenosed artery are studied. In this study, blood was modelled as non-Newtonian Bingham plastic fluid subjected to periodic body acceleration and slip velocity. The flow governing equations were solved analytically by using the perturbation method. By using the numerical approaches, the physiological parameters were analyzed, and the blood flow velocity distributions were generated graphically and discussed. From the flow results, the flow speed increases as slip velocity increases and decreases as the values of yield stress increases.

  12. Reducing blood loss during laparoscopic myomectomy by temporary uterine artery clamping using bulldog clamp

    Directory of Open Access Journals (Sweden)

    Kai-Jo Chiang

    2014-01-01

    Full Text Available Uterine myoma is the most common benign gynecologic tumor worldwide. Mini-invasive surgery has become popular for myomectomy, with advantages over laparotomy. However, reducing blood loss during laparoscopic myomectomy is a major concern for the surgeon because of the limitation in making a quick control bleeding during the operation. Several methods have proved to decrease blood flow, but are not always effective or available. We present a case of uterine myoma with the uterine arteries clamped by bulldog clamps during laparoscopic myomectomy. The myoma was removed successfully with minimal blood loss (<50 ml during the operation. This is an effective, safe, and reliable method for reducing bleeding during laparoscopic myomectomy that does not require ligation of the uterine artery.

  13. Constitutive modelling of an arterial wall supported by microscopic measurements

    Directory of Open Access Journals (Sweden)

    Vychytil J.

    2012-06-01

    Full Text Available An idealized model of an arterial wall is proposed as a two-layer system. Distinct mechanical response of each layer is taken into account considering two types of strain energy functions in the hyperelasticity framework. The outer layer, considered as a fibre-reinforced composite, is modelled using the structural model of Holzapfel. The inner layer, on the other hand, is represented by a two-scale model mimicing smooth muscle tissue. For this model, material parameters such as shape, volume fraction and orientation of smooth muscle cells are determined using the microscopic measurements. The resulting model of an arterial ring is stretched axially and loaded with inner pressure to simulate the mechanical response of a porcine arterial segment during inflation and axial stretching. Good agreement of the model prediction with experimental data is promising for further progress.

  14. Comparison of arterial and venous blood gases and the effects of analysis delay and air contamination on arterial samples in patients with chronic obstructive pulmonary disease and healthy controls.

    LENUS (Irish Health Repository)

    O'Connor, T M

    2012-01-31

    BACKGROUND: Arterial blood gases (ABGs) are often sampled incorrectly, leading to a \\'mixed\\' or venous sample. Delays in analysis and air contamination are common. OBJECTIVES: We measured the effects of these errors in patients with chronic obstructive pulmonary disease (COPD) exacerbations and controls. METHODS: Arterial and venous samples were analyzed from 30 patients with COPD exacerbation and 30 controls. Venous samples were analysed immediately and arterial samples separated into non-air-contaminated and air-contaminated specimens and analysed at 0, 30, 60, 90 and 180 min. RESULTS: Mean venous pH was 7.371 and arterial pH was 7.407 (p < 0.0001). There was a correlation between venous and arterial pH (r = 0.5347, p < 0.0001). The regression equation to predict arterial pH was: arterial pH = 4.2289 + 0.43113 . venous pH. There were no clinically significant differences in arterial PO associated with analysis delay. A statistically significant decline in pH was detected at 30 min in patients with COPD exacerbation (p = 0.0042) and 90 min in controls (p < 0.0001). A clinically significant decline in pH emerged at 73 min in patients with COPD exacerbation and 87 min in controls. Air contamination was associated with a clinically significant increase in PO in all samples, including those that were immediately analyzed. CONCLUSIONS: Arterial and venous pH differ significantly. Venous pH cannot accurately replace arterial pH. Temporal delays in ABG analysis result in a significant decline in measured pH. ABGs should be analysed within 30 min. Air contamination leads to an immediate increase in measured PO, indicating that air-contaminated ABGs should be discarded.

  15. Quantification of blood flow in the middle cerebral artery with phase-contrast MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Stock, K.W.; Wetzel, S.G.; Radue, E.W. [Dept. of Radiology, Division of Neuroradiology, University Hospital of Basel (Switzerland); Lyrer, P.A. [Dept. of Neurology, University Hospital of Basel (Switzerland)

    2000-11-01

    The aim of this study was to assess blood flow in the middle cerebral artery (MCA) according to age, gender, and side. Eighty-eight subjects without carotid obstruction were measured for mean velocity, vessel area, and volume flow rates of both MCA with phase-contrast MR. A high-resolution sequence with a matrix of 300 x 512 and a double oblique localizing strategy was used for measurement. A mean velocity of 33 {+-} 6.8 cm/s, a mean vessel area of 6.2 {+-} 1.2 mm{sup 2} and a mean flow rate of 121 {+-} 28 ml/min were measured in the MCA. Lower volume flow rates were seen in subjects aged over 50 years (p < 0.01). When comparing women with men, a lower vessel area (p < 0.05) of the MCA was counterbalanced by a higher velocity, resulting in no significant difference of the volume flow rate. No difference occurred between the right and the left side. Flow reduction occurs in the elderly. A lower vessel area of the MCA in women is compensated by a higher velocity. (orig.)

  16. Quantification of blood flow in the middle cerebral artery with phase-contrast MR imaging

    International Nuclear Information System (INIS)

    Stock, K.W.; Wetzel, S.G.; Radue, E.W.; Lyrer, P.A.

    2000-01-01

    The aim of this study was to assess blood flow in the middle cerebral artery (MCA) according to age, gender, and side. Eighty-eight subjects without carotid obstruction were measured for mean velocity, vessel area, and volume flow rates of both MCA with phase-contrast MR. A high-resolution sequence with a matrix of 300 x 512 and a double oblique localizing strategy was used for measurement. A mean velocity of 33 ± 6.8 cm/s, a mean vessel area of 6.2 ± 1.2 mm 2 and a mean flow rate of 121 ± 28 ml/min were measured in the MCA. Lower volume flow rates were seen in subjects aged over 50 years (p < 0.01). When comparing women with men, a lower vessel area (p < 0.05) of the MCA was counterbalanced by a higher velocity, resulting in no significant difference of the volume flow rate. No difference occurred between the right and the left side. Flow reduction occurs in the elderly. A lower vessel area of the MCA in women is compensated by a higher velocity. (orig.)

  17. Evaluation of the cerebrovascular pressure reactivity index using non-invasive finapres arterial blood pressure

    International Nuclear Information System (INIS)

    Kasprowicz, M; Kim, D J; Haubrich, C; Czosnyka, Z; Smielewski, P; Czosnyka, M; Schmidt, E

    2010-01-01

    A pressure reactivity index (PRx) can be assessed in patients with continuous monitoring of arterial blood pressure (ABP) and intracranial pressure (ICP) as a moving correlation coefficient between slow fluctuations of these two signals within a low frequency bandwidth. The study aimed to investigate whether the invasive ABP monitoring can be replaced with non-invasive measurement of ABP using a Finapres plethysmograph (fABP) to calculate the fPRx. There is a well-defined group of patients, suffering from hydrocephalus and undergoing CSF pressure monitoring, which may benefit from such a measurement. 41 simultaneous day-by-day monitoring of ICP, ABP and fABP were performed for about 30 min in 10 head injury patients. A Bland–Altman assessment for agreement was used to compare PRx and fPRx calculations. Performance metrics and the McNemary test were used to determine whether fPRx is sensitive enough to distinguish between functioning and disturbed cerebrovascular pressure reactivity. The fPRx correlated with PRx (R Spearman = 0.92, p < 0.001; bias = −0.04; lower and upper limits of agreement: −0.26 and 0.17, respectively). The fPRx distinguished between active and passive reactivity in more than 89% cases. The fPRx can be used with care for assessment of cerebrovascular reactivity in patients for whom invasive ABP measurement is not feasible. The fPRx is sensitive enough to distinguish between functional and deranged reactivity

  18. Estimation of arterial arrival time and cerebral blood flow from QUASAR arterial spin labeling using stable spline.

    Science.gov (United States)

    Castellaro, Marco; Peruzzo, Denis; Mehndiratta, Amit; Pillonetto, Gianluigi; Petersen, Esben Thade; Golay, Xavier; Chappell, Michael A; Bertoldo, Alessandra

    2015-12-01

    QUASAR arterial spin labeling (ASL) permits the application of deconvolution approaches for the absolute quantification of cerebral perfusion. Currently, oscillation index regularized singular value decomposition (oSVD) combined with edge-detection (ED) is the most commonly used method. Its major drawbacks are nonphysiological oscillations in the impulse response function and underestimation of perfusion. The aim of this work is to introduce a novel method to overcome these limitations. A system identification method, stable spline (SS), was extended to address ASL peculiarities such as the delay in arrival of the arterial blood in the tissue. The proposed framework was compared with oSVD + ED in both simulated and real data. SS was used to investigate the validity of using a voxel-wise tissue T1 value instead of using a single global value (of blood T1 ). SS outperformed oSVD + ED in 79.9% of simulations. When applied to real data, SS exhibited a physiologically realistic range for perfusion and a higher mean value with respect to oSVD + ED (55.5 ± 9.5 SS, 34.9 ± 5.2 oSVD + ED mL/100 g/min). SS can represent an alternative to oSVD + ED for the quantification of QUASAR ASL data. Analysis of the retrieved impulse response function revealed that using a voxel wise tissue T1 might be suboptimal. © 2014 Wiley Periodicals, Inc.

  19. Pressão arterial entre trabalhadores de curtume Blood pressure among tannery workers

    Directory of Open Access Journals (Sweden)

    Ricardo Cordeiro

    1998-10-01

    death in Brazil since the 1970s. High blood pressure has been the major risk factor among the above mentioned diseases. A negative correlation between occupational qualification and blood pressure has been observed among workers. The above mentioned facts bring out the importance of the knowledge of high blood pressure distribution among the different occupational groups. The aim of the present study was to describe the distribution of blood pressure in stable and homogeneous population of unskilled, low wage larning industrial workers. The Prevalence of high blood pressure was established for this specific group. This prevalence was also related to some biological and socio-economical covariates as compared with that among other occupational groups in Brazil. METHOD: The subjects were 73 active employees at a tannery in Botucatu, state of S.Paulo, Brazil, in July 1993. These subjects underwent blood pressure measurements, anamnesis and clinical examination. The results were compared with those of similar studies carried out in elsewhere Brazil. Age confounding was controlled by different techniques. RESULT: The crude prevalence of high blood pressure detected in this group of workers was of 56.1%, with 15.8% of isolated systolic hypertension. Alcohol abuse and smoking were associated with high blood pressure and isolated systolic hypertension in the population studied. DISCUSSION: Prevalence of hypertension in the group studied is significantly higher than that observed in other groups of workers studied in Brazil. Such a finding points to the need for further investigation so as to isolate those factors involved in the increased blood pressure found in this group.

  20. A fast analysis method for non-invasive imaging of blood flow in individual cerebral arteries using vessel-encoded arterial spin labelling angiography

    Science.gov (United States)

    Chappell, Michael A.; Okell, Thomas W.; Payne, Stephen J.; Jezzard, Peter; Woolrich, Mark W.

    2012-01-01

    Arterial spin labelling (ASL) MRI offers a non-invasive means to create blood-borne contrast in vivo for dynamic angiographic imaging. By spatial modulation of the ASL process it is possible to uniquely label individual arteries over a series of measurements, allowing each to be separately identified in the resulting angiographic images. This separation requires appropriate analysis for which a general Bayesian framework has previously been proposed. Here this framework is adapted for clinical dynamic angiographic imaging. This specifically addresses the issues of computational speed of the algorithm and the robustness required to deal with real patient data. An algorithm is proposed that can incorporate planning information about the arteries being imaged whilst adapting for subsequent patient movement. A fast maximum a posteriori solution is adopted and shown to be only marginally less accurate than Monte Carlo sampling under simulation. The final algorithm is demonstrated on in vivo data with analysis on a time scale of the order of 10 min, from both a healthy control and a patient with a vertebro-basilar occlusion. PMID:22322066

  1. Pulsatility Index of Blood Echogenicity of the Human Radial and Common Carotid Arteries: Relation with Age and Stroke

    International Nuclear Information System (INIS)

    Bok, Tae Hoon; Kong, Qi; Nam, Kweon Ho; Choi, Jay Chol; Paeng, Dong Guk

    2012-01-01

    In the present paper, the ultrasound blood images were measured at both the human radial artery(RA) and common carotid artery(CCA), depending on the age, and the pulsatility index of blood echogenicity(PIBE) was analyzed. In addition, the ultrasound blood images were measured at both RA and CCA of both the stroke patients and the control group, and PIBE was compared. PIBE of RA for the young group was similar with that for the old group (0.13±0.21 and 0.16±0.03). PIBE of CCA for the young group, however, was larger than that for the old group (0.70±0.21 and 0.32±0.01), and was more variable depending on the subject. Similarly, the fibrinogen concentrations of the patients (336±61 and 340±126 mg/dl) were more than that of the control group (264±38 and 43 mg/dl), for both RA and CCA. The results indicate the possibility of the ultrasonic test on the correlation between erythrocyte aggregation and stroke, and it is expected that the in-vivo EA measurement would be clinically useful.

  2. Twenty-four-hour exposure to altered blood flow modifies endothelial Ca2+-activated K+ channels in rat mesenteric arteries

    DEFF Research Database (Denmark)

    Hilgers, Rob H P; Janssen, Ger M J; Fazzi, Gregorio E

    2010-01-01

    We tested the hypothesis that changes in arterial blood flow modify the function of endothelial Ca2+-activated K+ channels [calcium-activated K+ channel (K(Ca)), small-conductance calcium-activated K+ channel (SK3), and intermediate calcium-activated K+ channel (IK1)] before arterial structural...... remodeling. In rats, mesenteric arteries were exposed to increased [+90%, high flow (HF)] or reduced blood flow [-90%, low flow (LF)] and analyzed 24 h later. There were no detectable changes in arterial structure or in expression level of endothelial nitric-oxide synthase, SK3, or IK1. Arterial relaxing...... arteries, the balance between the NO/prostanoid versus EDHF response was unaltered. However, the contribution of IK1 to the EDHF response was enhanced, as indicated by a larger effect of TRAM-34 and a larger residual NS309-induced relaxation in the presence of UCL 1684. Reduction of blood flow selectively...

  3. Distribution of the blood flow supplied by the vertebral artery in humans as assessed by emission CT

    International Nuclear Information System (INIS)

    Taki, W.; Handa, H.; Higa, T.; Tanada, S.; Fukuyama, H.; Fujita, T.; Yonekawa, Y.; Kameyama, M.; Torizuka, K.

    1984-01-01

    Though unilateral blood distribution of the vertebral artery has not been studied in humans, it is significant when considering the ischemic events especially embolic occlusion in vertebrobasilar system. To clarify the blood distribution, Krypton-81m was continuously infused into the vertebral arteries of 10 patients. Radioactivity was recorded by a rotating gamma camera. The perfusion images, reconstructed by computer in the transaxial plane, were classified according to whether the distribution was equal, or predominantly unilateral. Overlapping of blood supply from each vertebral artery was studied. In addition, the perfusion from one of the vertebral arteries revealed four distribution patterns with respect to laterality. A) ipsilateral; B) contralateral; C) bilateral; D) mosaic. Images obtained following perfusion of the vertebral artery show less uniformity compared to that of the internal carotid artery, suggesting a complicated vascular supply of the vertebral basilar territory. This complex distribution can be classified by the use of continuous infusion of Krypton-81m

  4. Effects of feeding on arterial blood gases in the American alligator Alligator mississippiensis.

    Science.gov (United States)

    Busk, M; Overgaard, J; Hicks, J W; Bennett, A F; Wang, T

    2000-10-01

    Reptiles habitually ingest large meals at infrequent intervals, leading to changes in acid-base status as the net secretion of acid to the stomach causes a metabolic alkalosis (the alkaline tide). In chronically cannulated and undisturbed amphibians and reptiles, the pH changes in arterial blood are, nevertheless, reduced by a concomitant respiratory acidosis (increased P(CO2) caused by a relative hypoventilation). Alligators (Alligator mississippiensis) have been reported to exhibit exceptionally large increases in plasma [HCO3(-)] following feeding, but these studies were based on blood samples obtained by cardiac puncture, so stress and disturbance may have affected the blood gas levels. Furthermore, crocodilian haemoglobin is characterised by a unique binding of HCO3(-) that act to reduce blood oxygen-affinity, and it has been proposed that this feature safeguards oxygen offloading by counteracting pH effects on blood oxygen-affinity. Therefore, to study acid-base regulation and the interaction between the alkaline tide and oxygen transport in more detail, we describe the arterial blood gas composition of chronically cannulated and undisturbed alligators before and after voluntary feeding (meal size 7.5+/-1% of body mass). Digestion was associated with an approximately fourfold increase in metabolic rate (from 0.63+/-0.04 to 2.32+/-0.24 ml O(2) min(-1)kg(-1)) and was accompanied by a small increase in the respiratory gas exchange ratio. The arterial P(O2) of fasting alligators was 60.3+/-6.8 mmHg (1 mmHg = 0.133 kPa) and reached a maximum of 81.3+/-2.7 mmHg at 96 h following feeding; there was only a small increase in lactate levels, so the increased metabolic rate seems to be entirely aerobic. Plasma [HCO3(-)] increased from 24.4+/-1.1 to 36.9+/-1.7 mmol l(-1) (at 24 h), but since arterial P(CO2) increased from 29.0+/-1.1 to 36.8+/-1.3 mmHg, arterial pH remained virtually unaffected (changing from 7.51+/-0.01 to 7.58+/-0.01 at 24 h). The changes in plasma [HCO

  5. Energy harvesting from arterial blood pressure for powering embedded brain sensors

    Science.gov (United States)

    Nanda, Aditya; Karami, M. Amin

    2016-04-01

    This paper investigates energy harvesting from arterial blood pressure via the piezoelectric effect by using a novel streaked cylinder geometry for the purpose of powering embedded micro-sensors in the brain. Initially, we look at the energy harvested by a piezoelectric cylinder placed inside an artery acted upon by blood pressure. Such an arrangement would be tantamount to constructing a stent out of piezoelectric materials. A stent is a cylinder placed in veins and arteries to prevent obstruction in blood flow. The governing equations of a conductor coated piezoelectric cylinder are obtained using Hamilton's principle. Pressure acting in arteries is radially directed and this is used to simplify the modal analysis and obtain the transfer function relating pressure to the induced voltage across the surface of the harvester. The power harvested by the cylindrical harvester is obtained for different shunt resistances. Radially directed pressure occurs elsewhere and we also look at harvesting energy from oil flow in pipelines. Although the energy harvested by the cylindrical energy harvester is significant at resonance, the natural frequency of the system is found to be very high. To decrease the natural frequency, we propose a novel streaked stent design by cutting it along the length, transforming it to a curved plate and decreasing the natural frequency. The governing equations corresponding to the new geometry are derived using Hamilton's principle and modal analysis is used to obtain the transfer function.

  6. Investigation Of Arterial Blood Pressure Level And Metabolic Indices In Patients With Arterial Hypertension At Pharmacotherapy With Antihypertensive Medicines Of Various Chemical Structure

    Directory of Open Access Journals (Sweden)

    G.Kh. Glybochko

    2009-12-01

    Full Text Available The research goal is to carry on the comparative analysis of medicines of various chemical structure, Telmisar-tan and Bisoprolol, and to reveal their effect on the arterial blood pressure level and the indices of various metabolic processes in patients with arterial hypertension. 60 out-patients with arterial hypertension (stage II risk III both males and females aged 33-55 have been under study taking Telmisartan and Bisoprolol for 3 months. While treating the patients the arterial blood pressure level control and biochemical investigations for determination the indices of metabolic processes have been carried out. The investigated medications have provided the decrease of systolic and diastolic arterial pressure parameters, the increase of concentration of total and ionized calcium, chlorine ions, urea and total bilirubin in blood plasma. Therapy with Telmisartan has shown more significant increase of potassium level in erythro-cytes, decrease of levels of natrium, glucose, glycolized hemoglobin and triglycerides and increased contents of alani-naminotransferase and aspartataminotransferase. The course of therapy with Bisoprolol has restored the normal level of magnesium in blood plasma, has not have any influence on carbohydrate and lipid metabolism, increased the level of alaninaminotransferase and significantly increased the contents of total and ionized calcium, urea and creatinine. 3-months therapy with Telmisartan and Bisoprolol has proved the decrease of systolic and diastolic arterial pressure in patients with arterial hypertension. The medications under study have had active and variable effects on metabolic indices

  7. Continuous Blood Glucose Monitoring May Detect Carotid Occlusion Intolerance during Carotid Artery Stenting.

    Science.gov (United States)

    Hiramatsu, Ryo; Furuse, Motomasa; Yagi, Ryokichi; Ohmura, Tomohisa; Ohnishi, Hiroyuki; Ikeda, Naokado; Nonoguchi, Naosuke; Kawabata, Shinji; Miyachi, Shigeru; Kuroiwa, Toshihiko

    2018-02-05

    The frequency of the occurrence of adverse events associated with carotid artery stenting (CAS) is usually low, but serious adverse events such as cerebral hyperperfusion syndrome (CHS) may occur. Real-time monitoring is ideal for the early detection of adverse events during the surgical procedure. This study aimed to evaluate continuous blood glucose (BG) monitoring for the detection of adverse events during CAS. Forty patients undergoing scheduled CAS were prospectively enrolled. An artificial pancreas was used for continuous BG monitoring (once per minute), using venous blood extracted at a rate of 2 mL/hr during CAS. The primary endpoint was a correlation between BG change and adverse events. CAS was discontinued in 1 patient, and BG was not measured in 5 patients (12.5%) because of the inability to extract blood. Among 34 evaluable patients, no patient developed CHS, but 3 patients (9%) experienced carotid occlusion intolerance. During CAS, BG was significantly higher in patients with carotid occlusion intolerance (median: 5 mg/dL) than in patients without carotid occlusion intolerance (median: 0 mg/dL) (P = 0.0221). A cutoff BG value ≥4 mg/dL during CAS showed 50% sensitivity and 100% specificity for the detection of carotid occlusion intolerance. There was no significant correlation between BG change and other adverse events. BG elevation may help detect carotid occlusion intolerance although it is still unknown whether BG monitoring can detect CHS. Further studies should validate that a cutoff BG elevation value of ≥4 mg/dL during CAS indicates carotid occlusion intolerance. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Virtual arterial blood pressure feedback improves chest compression quality during simulated resuscitation.

    Science.gov (United States)

    Rieke, Horst; Rieke, Martin; Gado, Samkon K; Nietert, Paul J; Field, Larry C; Clark, Carlee A; Furse, Cory M; McEvoy, Matthew D

    2013-11-01

    Quality chest compressions (CC) are the most important factor in successful cardiopulmonary resuscitation. Adjustment of CC based upon an invasive arterial blood pressure (ABP) display would be theoretically beneficial. Additionally, having one compressor present for longer than a 2-min cycle with an ABP display may allow for a learning process to further maximize CC. Accordingly, we tested the hypothesis that CC can be improved with a real-time display of invasively measured blood pressure and with an unchanged, physically fit compressor. A manikin was attached to an ABP display derived from a hemodynamic model responding to parameters of CC rate, depth, and compression-decompression ratio. The area under the blood pressure curve over time (AUC) was used for data analysis. Each participant (N=20) performed 4 CPR sessions: (1) No ABP display, exchange of compressor every 2 min; (2) ABP display, exchange of compressor every 2 min; (3) no ABP display, no exchange of the compressor; (4) ABP display, no exchange of the compressor. Data were analyzed by ANOVA. Significance was set at a p-valueAUC for cycles without ABP display was 5201 mm Hgs (95% confidence interval (CI) of 4804-5597 mm Hgs), and for cycles with ABP display 6110 mm Hgs (95% CI of 5715-6507 mm Hgs) (pAUC increase with ABP display for each participant was 20.2±17.4% 95 CI (p<0.0001). Our study confirms the hypothesis that a real-time display of simulated ABP during CPR that responds to participant performance improves achieved and sustained ABP. However, without any real-time visual feedback, even fit compressors demonstrated degradation of CC quality. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  9. Modeling of the blood flow in the lower extremities for dynamic diffuse optical tomography of peripheral artery disease

    Science.gov (United States)

    Marone, A.; Hoi, J. W.; Khalil, M. A.; Kim, H. K.; Shrikhande, G.; Dayal, R.; Hielscher, A. H.

    2015-07-01

    Peripheral Arterial Disease (PAD) is caused by a reduction of the internal diameters of the arteries in the upper or lower extremities mainly due to atherosclerosis. If not treated, its worsening may led to a complete occlusion, causing the death of the cells lacking proper blood supply, followed by gangrene that may require chirurgical amputation. We have recently performed a clinical study in which good sensitivities and specificities were achieved with dynamic diffuse optical tomography. To gain a better understanding of the physiological foundations of many of the observed effects, we started to develop a mathematical model for PAD. The model presented in this work is based on a multi-compartment Windkessel model, where the vasculature in the leg and foot is represented by resistors and capacitors, the blood pressure with a voltage drop, and the blood flow with a current. Unlike existing models, the dynamics induced by a thigh-pressure-cuff inflation and deflation during the measurements are taken into consideration. This is achieved by dynamically varying the resistances of the large veins and arteries. By including the effects of the thigh-pressure cuff, we were able to explain many of the effects observed during our dynamic DOT measurements, including the hemodynamics of oxy- and deoxy-hemoglobin concentration changes. The model was implemented in MATLAB and the simulations were normalized and compared with the blood perfusion obtained from healthy, PAD and diabetic patients. Our preliminary results show that in unhealthy patients the total system resistance is sensibly higher than in healthy patients.

  10. The genetic basis for altered blood vessel function in disease: large artery stiffening

    Directory of Open Access Journals (Sweden)

    Alex Agrotis

    2005-12-01

    Full Text Available Alex AgrotisThe Cell Biology Laboratory, Baker Heart Research Institute, Melbourne, Victoria, AustraliaAbstract: The progressive stiffening of the large arteries in humans that occurs during aging constitutes a potential risk factor for increased cardiovascular morbidity and mortality, and is accompanied by an elevation in systolic blood pressure and pulse pressure. While the underlying basis for these changes remains to be fully elucidated, factors that are able to influence the structure and composition of the extracellular matrix and the way it interacts with arterial smooth muscle cells could profoundly affect the properties of the large arteries. Thus, while age and sex represent important factors contributing to large artery stiffening, the variation in growth-stimulating factors and those that modulate extracellular production and homeostasis are also being increasingly recognized to play a key role in the process. Therefore, elucidating the contribution that genetic variation makes to large artery stiffening could ultimately provide the basis for clinical strategies designed to regulate the process for therapeutic benefit.Keywords: arterial stiffness, genes, polymorphism, extracellular matrix proteins

  11. Intermittent pneumatic leg compressions enhance muscle performance and blood flow in a model of peripheral arterial insufficiency.

    Science.gov (United States)

    Roseguini, Bruno T; Arce-Esquivel, Arturo A; Newcomer, Sean C; Yang, Hsiao T; Terjung, Ronald; Laughlin, M H

    2012-05-01

    Despite the escalating prevalence in the aging population, few therapeutic options exist to treat patients with peripheral arterial disease. Application of intermittent pneumatic leg compressions (IPC) is regarded as a promising noninvasive approach to treat this condition, but the clinical efficacy, as well the mechanistic basis of action of this therapy, remain poorly defined. We tested the hypothesis that 2 wk of daily application of IPC enhances exercise tolerance by improving blood flow and promoting angiogenesis in skeletal muscle in a model of peripheral arterial insufficiency. Male Sprague-Dawley rats were subjected to bilateral ligation of the femoral artery and randomly allocated to treatment or sham groups. Animals were anesthetized daily and exposed to 1-h sessions of bilateral IPC or sham treatment for 14-16 consecutive days. A third group of nonligated rats was also studied. Marked increases in treadmill exercise tolerance (∼33%, P < 0.05) and improved muscle performance in situ (∼10%, P < 0.05) were observed in IPC-treated animals. Compared with sham-treated controls, blood flow measured with isotope-labeled microspheres during in situ contractions tended to be higher in IPC-treated animals in muscles composed of predominantly fast-twitch white fibers, such as the plantaris (∼93%, P = 0.02). Capillary contacts per fiber and citrate synthase activity were not significantly altered by IPC treatment. Collectively, these data indicate that IPC improves exercise tolerance in a model of peripheral arterial insufficiency in part by enhancing blood flow to collateral-dependent tissues.

  12. Cerebral small-resistance artery structure and cerebral blood flow in normotensive subjects and hypertensive patients

    Energy Technology Data Exchange (ETDEWEB)

    De Ciuceis, Carolina; Porteri, Enzo; Rizzoni, Damiano; Boari, Gianluca E.M.; Rosei, Enrico Agabiti [University of Brescia, Clinica Medica, Department of Clinical and Experimental Sciences, Brescia (Italy); Cornali, Claudio; Mardighian, Dikran; Fontanella, Marco M. [University of Brescia, Section of Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy); Pinardi, Chiara [Spedali Civili, Medical Physics Unit, Brescia (Italy); University of Brescia, Section of Neuroradiology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy); Rodella, Luigi F.; Rezzani, Rita [University of Brescia, Section of Anatomy, Department of Clinical and Experimental Sciences, Brescia (Italy); Gasparotti, Roberto [University of Brescia, Section of Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy); University of Brescia, Section of Neuroradiology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, Brescia (Italy)

    2014-12-15

    The aim of this study was to prospectively investigate whether the structure of cerebral small-resistance arteries is related to cerebral perfusion parameters as measured with dynamic susceptibility-weighted contrast magnetic resonance imaging (DSC-MRI) in a selected cohort of hypertensive and normotensive patients. Ten hypertensive and 10 normotensive patients were included in the study. All patients underwent neurosurgical intervention for an intracranial tumor and were investigated with DSC-MRI at 1.5 T. Cerebral small-resistance arteries were dissected from a small portion of morphologically normal cerebral tissue and mounted on an isometric myograph for the measurement of the media-to-lumen (M/L) ratio. A quantitative assessment of cerebral blood flow (CBF) and volume (CBV) was performed with a region-of-interest approach. Correlation coefficients were calculated for normally distributed variables. The institutional review board approved the study, and informed consent was obtained from all patients. Compared with normotensive subjects, hypertensive patients had significantly lower regional CBF (mL/100 g/min) in the cortical grey matter (55.63 ± 1.90 vs 58.37 ± 2.19, p < 0.05), basal ganglia (53.34 ± 4.39 vs 58.22. ± 4.33, p < 0.05), thalami (50.65 ± 3.23 vs 57.56 ± 4.45, p < 0.01), subcortical white matter (19.32 ± 2.54 vs 22.24 ± 1.9, p < 0.05), greater M/L ratio (0.099 ± 0.013 vs 0.085 ± 0.012, p < 0.05), and lower microvessel density (1.66 ± 0.67 vs 2.52 ± 1.28, p < 0.05). A statistically significant negative correlation was observed between M/L ratio of cerebral arteries and CBF in the cortical grey matter (r = -0.516, p < 0.05), basal ganglia (r = -0.521, p < 0.05), thalami (r = -0.527 p < 0.05), and subcortical white matter (r = -0.612, p < 0.01). Our results indicate that microvascular structure might play a role in controlling CBF, with possible clinical consequences. (orig.)

  13. Non-dipping blood pressure patterns and arterial stiffness parameters in patients with Behcet's disease.

    Science.gov (United States)

    Celik, Gulperi; Yilmaz, Sema; Ergulu Esmen, Serpil

    2015-12-01

    Behcet's disease is a multisystemic vasculitis involving veins and arteries of various sizes. Non-dipping status, augmentation index and pulse wave velocity are important determinants of cardiovascular mortality and morbidity. We investigated the non-dipping status and arterial stiffness in patients with Behcet's disease. In this cross-sectional study, we examined the vascular parameters of 96 patients with Behcet's disease (53% female) and 60 age- and sex-matched control subjects. The non-dipping status and arterial distensibility were assessed using a Mobil-O-Graph Arteriograph, an automatic oscillometric device. In total, 65.6% of 96 patients were systolic non-dippers, and 34.4% exhibited high augmentation indices. Ten percent of the control subjects were systolic non-dippers, and 11.7% exhibited high augmentation indices. Nocturnal decreases in systolic blood pressure correlated with central systolic blood pressure and diastolic blood pressure, as well as nocturnal decreases in diastolic blood pressure. Furthermore, non-dipper patients with Behcet's disease exhibited higher nocturnal cardiac outputs than did dipper patients with Behcet's disease. Augmentation index correlated negatively with C-reactive protein and correlated positively with both 24 h and nocturnal peripheral resistance, as well as 24 h pulse wave velocity. The patients with high augmentation indices exhibited lower creatinine clearance, as well as lower nocturnal cardiac outputs, higher 24 h peripheral resistance and higher 24 h pulse wave velocities. Non-dipping status and arterial stiffness may exacerbate the harmful cardiovascular effects of the other. In addition to conventional risk factors, non-dipping status and arterial stiffness should be examined during the follow-up evaluations of patients with Behcet's disease.

  14. Quantitative measurement of total cerebral blood flow using 2D phase-contrast MRI and doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Keum Soo; Choi, Sun Seob; Lee, Young Il [Dong-A Univ., College of Medicine, Busan (Korea, Republic of)

    2001-12-01

    To compare of quantitative measurement of the total cerebral blood flow using two-dimensional phase-contrast MR imaging and Doppler ultrasound. In 16 volunteers (mean age, 26 years; mean body weight, 66 kg) without abnormal medical histories, two-dimensional phase-contrast MR imaging was performed at the level of the C2-3 inter vertebral disc for flow measurement of the internal carotid arteries and the vertebral arteries. Volume flow measurements using Doppler ultrasound were also performed at the internal carotid arteries 2cm above the carotid bifurcation, and at the vertebral arteries at the level of the upper pole of the thyroid gland. Flows in the four vessels measured by the two methods were compared using Wilcoxon's correlation analysis and the median score. Total cerebral blood flows were calculated by summing these four vessel flows, and mean values for the 16 volunteers were calculated. Cerebral blood flows measured by 2-D phase-contrast MR imaging and Doppler ultrasounds were 233 and 239 ml/min in the right internal carotid artery, 250 and 248 ml/min in the left internal carotid artery, 62 and 56 ml/min in the right vertebral artery, and 83 and 68 ml/min in the left vertebral artery. Correlation coefficients of the blood flows determined by the two methods were 0.48, 0.54, 0.49, and 0.62 in each vessel, while total cerebral blood flows were 628{+-}68 (range, 517 to 779) ml/min and 612{+-}79 (range, 482 to 804)ml/min, respectively. Total cerebral blood flow was easily measured using 2-D phase-contrast MR imaging and Doppler ultrasound, and the two noninvasive methods can therefore be used clinically for the measurement of total cerebral blood flow.

  15. Tale of two sites: capillary versus arterial blood glucose testing in the operating room.

    Science.gov (United States)

    Akinbami, Felix; Segal, Scott; Schnipper, Jeffrey L; Stopfkuchen-Evans, Matthias; Mills, Jonathan; Rogers, Selwyn O

    2012-04-01

    Pre- and intraoperative glycemic control has been identified as a putative target to improve outcomes of surgical patients. Glycemic control requires frequent monitoring of blood glucose levels with appropriate adjustments. However, monitoring standards have been called into question, especially in cases in which capillary samples are used. Point-of-care testing (POCT) using capillary samples and glucometers has been noted to give relatively accurate results for critically ill patients. However, the package inserts of most glucometers warn that they should not be used for patients in shock. This has led clinicians to doubt their accuracy in the operating room. The accuracy of capillary samples when tested in patients undergoing surgical procedures has not been proven. This study aims to determine the accuracy of intraoperative blood glucose values using capillary samples relative to arterial samples. A prospective study was conducted by collecting paired capillary and arterial samples of patients undergoing major operations at a tertiary medical center from August 2009 to May 2011. Subjects were a convenience sample of patients who had arterial lines and needed glucose testing while undergoing the procedure. Precision Xceed Pro (Abbott) handheld glucometers were used to obtain the blood glucose values. Our primary outcome of interest was the degree of correlation between capillary and arterial blood glucose values or the degree to which arterial glucose levels can be predicted by capillary glucose samples. We used linear regression and the Student t tests for statistical analyses. Seventy-two-paired samples were collected. Of the cases, 54% were major abdominal operations, whereas 24% were vascular operations. The mean values ± standard deviation for glucose levels were 146 ± 35 mg/dL (capillary) and 147 ± 36 mg/dL (arterial). The mean time ± standard deviation between the collection of both samples was 3.5 ± 1.3 minutes. The regression coefficient showed a

  16. Arterial blood supply to midbrain, thalamus and internal capsule on CT, 3

    International Nuclear Information System (INIS)

    Takeshita, Gen; Ottomo, Michinori; Sasaki, Taisuke; Fukuda, Eiko.

    1984-01-01

    The selective injection of dye into the anterior choroidal artery (blue), the medial posterior choroidal artery (green), and the lateral posterior choroidal artery (red), using seven post-mortem brains, was performed. After fixation, sections parallel with the orbito-meatal line were obtained. The distribution of the anterior choroidal artery was visualized in the uncal region of the temporal lobe and the cerebral peduncle below the slice of the third ventricle. On the slice of the third ventricle, the lateral part of the geniculate region, the globus pallidus, and the posterior limb of the internal capsule were supplied by the anterior choroidal artery. The blood supply of the posterior limb of the internal capsule was also demonstrated on the slice of the anterior horn and on the body of the lateral ventricle. The distribution of the medial posterior choroidal artery was visualized in the tegmentum of the midbrain below the slice of the third ventricle, and on the slice of the anterior horn, the pineal body and the posterior part of the thalamus were also supplied. The distribution of the lateral posterior choroidal artery was visualized in the lateral part of the midbrain, around the red nucleus, below the slice of the third ventricle, and on the slice of the third ventricle, the upper part of the cerebral peduncle, the posterior part of the hypothalamus, and the medial part of the geniculate region were also supplied. Also, distribution to the medial and posterior parts of the thalamus was noted on the slice of the anterior horn. It was quite useful to identify the distribution of each choroidal artery on CT sections for the CT diagnosis of cerebrovascular disorders. (author)

  17. On the shape of the common carotid artery with implications for blood velocity profiles

    International Nuclear Information System (INIS)

    Manbachi, Amir; Hoi, Yiemeng; Steinman, David A; Wasserman, Bruce A; Lakatta, Edward G

    2011-01-01

    Clinical and engineering studies typically assume that the common carotid artery (CCA) is straight enough to assume fully developed flow, yet recent studies have demonstrated the presence of skewed velocity profiles. Toward elucidating the influence of mild vascular curvatures on blood flow patterns and atherosclerosis, this study aimed to characterize the three-dimensional shape of the human CCA. The left and right carotid arteries of 28 participants (63 ± 12 years) in the VALIDATE (Vascular Aging-–The Link that Bridges Age to Atherosclerosis) study were digitally segmented from 3D contrast-enhanced magnetic resonance angiograms, from the aortic arch to the carotid bifurcation. Each CCA was divided into nominal cervical and thoracic segments, for which curvatures were estimated by least-squares fitting of the respective centerlines to planar arcs. The cervical CCA had a mean radius of curvature of 127 mm, corresponding to a mean lumen:curvature radius ratio of 1:50. The thoracic CCA was significantly more curved at 1:16, with the plane of curvature tilted by a mean angle of 25° and rotated close to 90° with respect to that of the cervical CCA. The left CCA was significantly longer and slightly more curved than the right CCA, and there was a weak but significant increase in CCA curvature with age. Computational fluid dynamic simulations carried out for idealized CCA geometries derived from these and other measured geometric parameters demonstrated that mild cervical curvature is sufficient to prevent flow from fully-developing to axisymmetry, independent of the degree of thoracic curvature. These findings reinforce the idea that fully developed flow may be the exception rather than the rule for the CCA, and perhaps other nominally long and straight vessels

  18. Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse

    Directory of Open Access Journals (Sweden)

    Min-Ho Jun

    2016-05-01

    Full Text Available The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a circular-type seven-channel piezoresistive sensor array using face-down bonding (FDB as one of the sensor combination methods. The three-layered housing structure that included independent pressure sensor units using the FDB method not only enabled elimination of the crosstalk among channels, but also allowed various array patterns to be created for effective pulse measurement. The sensors were arranged in a circular-type arrangement such that they could estimate the direction of the radial artery and precisely measure the pulse wave. The performance of the fabricated sensor array was validated by evaluating the sensor sensitivity per channel, and the possibility of estimating the blood vessel direction was demonstrated through a radial artery pulse simulator. We expect the proposed sensor to allow accurate extraction of the pulse indices for pulse diagnosis.

  19. Combined resistance and endurance exercise training improves arterial stiffness, blood pressure, and muscle strength in postmenopausal women.

    Science.gov (United States)

    Figueroa, Arturo; Park, Song Y; Seo, Dae Y; Sanchez-Gonzalez, Marcos A; Baek, Yeong H

    2011-09-01

    Menopause is associated with increased arterial stiffness and reduced muscle strength. Combined resistance (RE) and endurance (EE) exercise training can decrease brachial-ankle pulse wave velocity (baPWV), an index of arterial stiffness, in young men. We tested the hypothesis that combined circuit RE and EE training would improve baPWV, blood pressure (BP), and muscle strength in postmenopausal women. Twenty-four postmenopausal women (age 47-68 y) were randomly assigned to a "no exercise" control (n = 12) or to combined exercise training (EX; n = 12) group. The EX group performed concurrent circuit RE training followed by EE training at 60% of the predicted maximal heart rate (HR) 3 days per week. Brachial systolic BP, diastolic BP, mean arterial pressure, baPWV, HR, and dynamic and isometric muscle strength were measured before and after the 12-week study. Mean ± SE baPWV (-0.8 ± 0.2 meters/s), systolic BP (-6.0 ± 1.9 mm Hg), diastolic BP (-4.8 ± 1.7 mm Hg), HR (-4.0 ± 1.0 beats/min), and mean arterial pressure (-5.1 ± 1.6 mm Hg) decreased (P hypertension and frailty in postmenopausal women.

  20. Relationships Between Components of Blood Pressure and Cardiovascular Events in Patients with Stable Coronary Artery Disease and Hypertension.

    Science.gov (United States)

    Vidal-Petiot, Emmanuelle; Greenlaw, Nicola; Ford, Ian; Ferrari, Roberto; Fox, Kim M; Tardif, Jean-Claude; Tendera, Michal; Parkhomenko, Alexander; Bhatt, Deepak L; Steg, P Gabriel

    2018-01-01

    Observational studies have shown a J-shaped relationship between diastolic blood pressure (BP) and cardiovascular events in hypertensive patients with coronary artery disease. We investigated whether the increased risk associated with low diastolic BP reflects elevated pulse pressure (PP). In 22 672 hypertensive patients with coronary artery disease from the CLARIFY registry (Prospective Observational Longitudinal Registry of Patients With Stable Coronary Artery Disease), followed for a median of 5.0 years, BP was measured annually and averaged. The relationships between PP and diastolic BP, alone or combined, and the primary composite outcome (cardiovascular death or myocardial infarction) were analyzed using multivariable Cox proportional hazards models. Adjusted hazard ratios for the primary outcome were 1.62 (95% confidence interval [CI], 1.40-1.87), 1.00 (ref), 1.07 (95% CI, 0.94-1.21), 1.54 (95% CI, 1.32-1.79), and 2.34 (95% CI, 1.95-2.81) for PPhypertensive patients with coronary artery disease persists in patients within the lowest-risk PP range and is therefore unlikely to be solely the consequence of an increased PP reflecting advanced vascular disease. URL: http://www.clarify-registry.com. Unique identifier: ISRCTN43070564. © 2017 American Heart Association, Inc.

  1. Tracer measured substrate turnover requires arterial sampling downstream of infusion site

    International Nuclear Information System (INIS)

    Stanley, W.C.; Neese, R.A.; Gertz, E.W.; Wisneski, J.A.; Morris, D.L.; Brooks, G.A.

    1986-01-01

    Measurement of metabolite turnover (Rt) with radioactive tracers is done by either infusing tracer venously and sampling specific activity (SA) arterially (V-A modes), or by infusing into the aorta and sampling venous blood (A-V mode). Using the Fick principle, the necessity for using the V-A mode can be demonstrated. If tracer is infused into the left ventricle, in a steady state the Rt is the product of arterial trace concentration, the cardiac output, and the tracer extraction ratio for the whole body. This is expressed as: Rt = Ca x Qx ((*Ca - *Cv)/*Ca) (Eq1) where C=trace concentration (μmol/ml), *C=tracer conc. (dpm/ml), a=arterial, v-=mixed venous, and Q=cardiac output (ml/min). Rearranging the equation: Rt = Qx(*Ca - *Cv)/SAa = F/SAa (Eq2) where SAa is *Ca/Ca, and Qx (*Ca-*Cv) equals the infusion rate (F). The authors compared Eqs1 and 2 (Rt = F/SAa) in 3 anesthetized dogs in which [1- 14 C] lactate was infused into the left ventricle, and blood was sampled arterially downstream from the infusion site and in the pulmonary artery. Eqs 1 and 2 gave similar results for Rt (45.9 vs. 43.9 μmol/kg min), while substituting SAv for SAa (A-V mode) into Eq 2 gave a higher Rt (53.6). When SAv (A-V mode) is used, the specific activity seen by the tissues (SAa) is not considered in the calculation of Rt. Therefore, only the V-A mode meets the requirements for tracer measured metabolite turnover

  2. Integration of a capacitive pressure sensing system into the outer catheter wall for coronary artery FFR measurements

    Science.gov (United States)

    Stam, Frank; Kuisma, Heikki; Gao, Feng; Saarilahti, Jaakko; Gomes Martins, David; Kärkkäinen, Anu; Marrinan, Brendan; Pintal, Sebastian

    2017-05-01

    The deadliest disease in the world is coronary artery disease (CAD), which is related to a narrowing (stenosis) of blood vessels due to fatty deposits, plaque, on the arterial walls. The level of stenosis in the coronary arteries can be assessed by Fractional Flow Reserve (FFR) measurements. This involves determining the ratio between the maximum achievable blood flow in a diseased coronary artery and the theoretical maximum flow in a normal coronary artery. The blood flow is represented by a pressure drop, thus a pressure wire or pressure sensor integrated in a catheter can be used to calculate the ratio between the coronary pressure distal to the stenosis and the normal coronary pressure. A 2 Fr (0.67mm) outer diameter catheter was used, which required a high level of microelectronics miniaturisation to fit a pressure sensing system into the outer wall. The catheter has an eccentric guidewire lumen with a diameter of 0.43mm, which implies that the thickest catheter wall section provides less than 210 microns height for flex assembly integration consisting of two dies, a capacitive MEMS pressure sensor and an ASIC. In order to achieve this a very thin circuit flex was used, and the two chips were thinned down to 75 microns and flip chip mounted face down on the flex. Many challenges were involved in obtaining a flex layout that could wrap into a small tube without getting the dies damaged, while still maintaining enough flexibility for the catheter to navigate the arterial system.

  3. Placental blood flow measurements with radioisotopes in the pregnant guinea pig

    International Nuclear Information System (INIS)

    Schmitt, R.; Giese, W.; Kurz, C.S.; Kuenzel, W.

    1976-01-01

    In 15 pregnant guinea pigs near term the blood flow (BF) of the myometrium and the placenta as well as the cardiac output were measured with 99 Tcsup(m)-labelled microspheres. In front of one placenta the clearance of 133 Xe was estimated in the same animal. For the 133 Xe measurement a theoretical concept is presented. The mean placental BF is 105ml/(minx100g)(SD:84) for 99 Tcsup(m) and 244(SD:80)ml/(minx100g) for 133 Xe. The difference in both flow values is assumed to be related to foetal placental BF. The placental blood flow is also related to the location of the placenta in the uterine horn. The ratio of myometrial blood flow to placental blood flow decreased with an increase in the mean arterial blood pressure. The measurements are a preliminary report of an attempt to compare two different methods in measuring placental blood flow. (author)

  4. Conventional blood conservation techniques in 500 consecutive coronary artery bypass operations.

    Science.gov (United States)

    Ovrum, E; Holen, E A; Abdelnoor, M; Oystese, R

    1991-09-01

    With use of a nonpharmacological, simple, and inexpensive program for blood conservation, 500 consecutive patients underwent elective coronary artery bypass grafting without need of homologous red cell transfusions in 493 (98.6%). At least one internal mammary artery was grafted in all but 1 patient, with supplemental saphenous vein grafts. Intraoperatively, autologous heparinized blood was removed before bypass and retransfused at the conclusion of extracorporeal circulation. The volume remaining in the oxygenator and tubing set was returned without cell processing or hemofiltration. Using the hard-shell cardiotomy reservoir from the heart-lung machine, autotransfusion of the shed mediastinal blood was continued hourly up to 18 hours after operation. The mean postoperative mediastinal blood loss was 643 +/- 354 mL, whereas 624 +/- 296 mL was autotransfused. Thirteen patients (2.6%) needed reexploration for bleeding, of whom 7 (7/500, 1.4%) received homologous blood. No other patients required red cell transfusions. In addition, 9 patients were given a mean of 2.6 units of fresh frozen plasma because of suspected coagulopathy. No platelets were transfused, and no cryoprecipitate therapy was undertaken. Thus, in total, 484 patients (96.8%) were not exposed to any homologous blood products during the hospital stay. At discharge, the mean hemoglobin concentration was 121 +/- 14 g/L (12.1 +/- 1.4 g/dL) and the hematocrit, 0.36 +/- 0.04. Postoperative complications were few. There was one in-hospital death (0.2%).

  5. Investigation of spiral blood flow in a model of arterial stenosis.

    Science.gov (United States)

    Paul, Manosh C; Larman, Arkaitz

    2009-11-01

    The spiral component of blood flow has both beneficial and detrimental effects in human circulatory system [Stonebridge PA, Brophy CM. Spiral laminar flow in arteries? Lancet 1991; 338: 1360-1]. We investigate the effects of the spiral blood flow in a model of three-dimensional arterial stenosis with a 75% cross-sectional area reduction at the centre by means of computational fluid dynamics (CFD) techniques. The standard k-omega model is employed for simulation of the blood flow for the Reynolds number of 500 and 1000. We find that for Re=500 the spiral component of the blood flow increases both the total pressure and velocity of the blood, and some significant differences are found between the wall shear stresses of the spiral and non-spiral induced flow downstream of the stenosis. The turbulent kinetic energy is reduced by the spiral flow as it induces the rotational stabilities in the forward flow. For Re=1000 the tangential component of the blood velocity is most influenced by the spiral speed, but the effect of the spiral flow on the centreline turbulent kinetic energy and shear stress is mild. The results of the effects of the spiral flow are discussed in the paper along with the relevant pathological issues.

  6. The mechanical properties of the systemic and pulmonary arteries of Python regius correlate with blood pressures.

    Science.gov (United States)

    van Soldt, Benjamin J; Danielsen, Carl Christian; Wang, Tobias

    2015-12-01

    Pythons are unique amongst snakes in having different pressures in the aortas and pulmonary arteries because of intraventricular pressure separation. In this study, we investigate whether this correlates with different blood vessel strength in the ball python Python regius. We excised segments from the left, right, and dorsal aortas, and from the two pulmonary arteries. These were subjected to tensile testing. We show that the aortic vessel wall is significantly stronger than the pulmonary artery wall in P. regius. Gross morphological characteristics (vessel wall thickness and correlated absolute amount of collagen content) are likely the most influential factors. Collagen fiber thickness and orientation are likely to have an effect, though the effect of collagen fiber type and cross-links between fibers will need further study. © 2015 Wiley Periodicals, Inc.

  7. Increasing arterial blood pressure with norepinephrine does not improve microcirculatory blood flow: a prospective study

    NARCIS (Netherlands)

    Dubin, Arnaldo; Pozo, Mario O.; Casabella, Christian A.; Palizas, Fernando; Murias, Gaston; Moseinco, Miriam C.; Kanoore Edul, Vanina S.; Estenssoro, Elisa; Ince, Can

    2009-01-01

    Introduction Our goal was to assess the effects of titration of a norepinephrine infusion to increasing levels of mean arterial pressure (MAP) on sublingual microcirculation. Methods Twenty septic shock patients were prospectively studied in two teaching intensive care units. The patients were

  8. Blood flow parameters of the superior mesenteric artery as an early predictor of intestinal dysmotility in preterm infants

    International Nuclear Information System (INIS)

    Robel-Tillig, Eva; Knuepfer, Matthias; Pulzer, Ferdinand; Vogtmann, Christoph

    2004-01-01

    Blood flow parameters in the superior mesenteric artery (SMA) change with vasoconstriction or vasodilatation of the intestinal vascular bed. In cases of severe growth retardation as a result of haemodynamic disturbances, the blood flow changes persist into postnatal life. To assess early changes of Doppler sonographic blood flow parameters in the SMA for prediction of later intestinal motility disturbances in preterm infants and tolerance of enteral feeding during the first week of life. Doppler sonographic blood flow parameters in the SMA were measured on the first day of life and the following 5 days in 478 neonates with a birth weight below 1,500 g. According to the Doppler results, the neonates were divided into two groups - those with pathological parameters and those with normal blood flow parameters. Correlations between blood flow parameters, the development of intestinal dysmotility and the tolerated amount of enteral feeding were calculated. Pathological blood flow parameters were observed in 148 neonates (group 1) and normal blood flow parameters in 330 neonates (group 2). Intestinal motility disturbance occurred in 125 neonates (83%) of group 1 and 47 neonates (15%) of group 2. Neonates in group 2 tolerated significantly more feed by the fifth day of life than neonates in group 1. Postnatal adaptation did not differ between the two groups, although the majority of neonates with intestinal dysmotility were small for gestational age. The predictive value of blood flow parameters for prediction of intestinal motility revealed high sensitivity and specificity by the first postnatal day, 2 or 3 days before development of clinical signs of intestinal dysmotility. There was a strong negative correlation between pathological pulsatility index on day 1 and the quantity of tolerated enteral feeding on day 5. Pathological blood flow parameters in the SMA can predict problems of intestinal motility and tolerance of enteral feeding. With the early detection of these

  9. An effective fractal-tree closure model for simulating blood flow in large arterial networks.

    Science.gov (United States)

    Perdikaris, Paris; Grinberg, Leopold; Karniadakis, George Em

    2015-06-01

    The aim of the present work is to address the closure problem for hemodynamic simulations by developing a flexible and effective model that accurately distributes flow in the downstream vasculature and can stably provide a physiological pressure outflow boundary condition. To achieve this goal, we model blood flow in the sub-pixel vasculature by using a non-linear 1D model in self-similar networks of compliant arteries that mimic the structure and hierarchy of vessels in the meso-vascular regime (radii [Formula: see text]). We introduce a variable vessel length-to-radius ratio for small arteries and arterioles, while also addressing non-Newtonian blood rheology and arterial wall viscoelasticity effects in small arteries and arterioles. This methodology aims to overcome substantial cut-off radius sensitivities, typically arising in structured tree and linearized impedance models. The proposed model is not sensitive to outflow boundary conditions applied at the end points of the fractal network, and thus does not require calibration of resistance/capacitance parameters typically required for outflow conditions. The proposed model convergences to a periodic state in two cardiac cycles even when started from zero-flow initial conditions. The resulting fractal-trees typically consist of thousands to millions of arteries, posing the need for efficient parallel algorithms. To this end, we have scaled up a Discontinuous Galerkin solver that utilizes the MPI/OpenMP hybrid programming paradigm to thousands of computer cores, and can simulate blood flow in networks of millions of arterial segments at the rate of one cycle per 5 min. The proposed model has been extensively tested on a large and complex cranial network with 50 parent, patient-specific arteries and 21 outlets to which fractal trees where attached, resulting to a network of up to 4,392,484 vessels in total, and a detailed network of the arm with 276 parent arteries and 103 outlets (a total of 702,188 vessels

  10. Skin perfusion pressure measured by isotope washout in legs with arterial occlusive disease. Evaluation of different tracers, comparison to segmental systolic pressure, angiography and transcutaneous oxygen tension and variations during changes in systemic blood pressure

    DEFF Research Database (Denmark)

    Holstein, P; Trap-Jensen, J; Bagger, H

    1983-01-01

    Hg (range 18-98) (P less than 0.02). The average washout constant for the three different tracers were approximately equal and correlated statistically significant with the SPP; (2) In 59 legs with AOD, segmental SPP was compared to segmental systolic blood pressures on the thigh, calf, ankle and first...... digit (strain gauge technique). The two different methods correlated statistically significant at all four levels, but the systolic blood pressures were higher than the SPP in particular in diabetic legs; (3) Angiograms in 35 legs with AOD showed that the SPP on the ankle was only consistently decreased...

  11. Continuous monitoring of arterial blood gases and pH during intraoperative rapid blood administration using a Paratrend sensor.

    Science.gov (United States)

    Vretzakis, G; Papaziogas, B; Matsaridou, E; Vasiliadou, G; Papadopoulos, G; Patsialas, C; Kostopoulou, F

    2000-01-01

    The aim of this study was to determine the effects of rapid transfusion of packed red cells on the arterial blood gases and acid-base status of the recipient. We studied 16 patients (mean age 66.3+/-9.9 years) who received rapid transfusion of 632.8+/-287.2 g of packed red cells in CPDA-1, stored before use for a period of 15.2+/-4.4 days. During transfusion, monitoring of pH, PCO2 and PO2 was continuous using an intra-arterial multiparameter sensor (Paratrend 7, Biomedical Sensors, UK). The rate of the transfusion was 73.1+/-9.6 g/min and the duration of observation was 35.8+/-12.8 min. Arterial pH decreased from 7.446+/-0.023 to 7.385+/-0.034 (pDelta pH and delta PCO2 showed significant correlation to the weight and the age of the transfused blood (pPO2 were not specific and our clinical impression was that they were related to unmeasured parameters. Our findings suggest that the fall in pH and the elevation in PCO2 which occur during rapid transfusion of packed red cells may go undetected or be misinterpreted if the acid-base status of the recipient is not monitored continuously. These alterations are mainly of metabolic character and depend on the amount and age of the transfused component. Our data suggest that arterial sampling is essential during massive transfusions.

  12. C1-esterase inhibitor protects against early vein graft remodeling under arterial blood pressure.

    Science.gov (United States)

    Krijnen, Paul A J; Kupreishvili, Koba; de Vries, Margreet R; Schepers, Abbey; Stooker, Wim; Vonk, Alexander B A; Eijsman, Leon; Van Hinsbergh, Victor W M; Zeerleder, Sacha; Wouters, Diana; van Ham, Marieke; Quax, Paul H A; Niessen, Hans W M

    2012-01-01

    Arterial pressure induced vein graft injury can result in endothelial loss, accelerated atherosclerosis and vein graft failure. Inflammation, including complement activation, is assumed to play a pivotal role herein. Here, we analyzed the effects of C1-esterase inhibitor (C1inh) on early vein graft remodeling. Human saphenous vein graft segments (n=8) were perfused in vitro with autologous blood either supplemented or not with purified human C1inh at arterial pressure for 6h. The vein segments and perfusion blood were analyzed for cell damage and complement activation. In addition, the effect of purified C1inh on vein graft remodeling was analyzed in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. Application of C1inh in the in vitro perfusion model resulted in significantly higher blood levels and significantly more depositions of C1inh in the vein wall. This coincided with a significant reduction in endothelial loss and deposition of C3d and C4d in the vein wall, especially in the circular layer, compared to vein segments perfused without supplemented C1inh. Administration of purified C1inh significantly inhibited vein graft intimal thickening in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. C1inh significantly protects against early vein graft remodeling, including loss of endothelium and intimal thickening. These data suggest that it may be worth considering its use in patients undergoing coronary artery bypass grafting. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Results and validity of renal blood flow measurements using Xenon 133

    International Nuclear Information System (INIS)

    Serres, P.; Danet, B.; Guiraud, R.; Durand, D.; Ader, J.L.

    1975-01-01

    The renal blood flow was measured by external recording of the xenon 133 excretion curve. The study involved 45 patients with permanent high blood pressure and 7 transplant patients. The validity of the method was checked on 10 dogs. From the results it seems that the cortical blood flow, its fraction and the mean flow rate are the most representative of the renal haemodynamics parameters, from which may be established the repercussions of blood pressure on kidney vascularisation. Experiments are in progress on animals to check the compartment idea by comparing injections into the renal artery and into various kidney tissues in situ [fr

  14. Prognostic significance of distal blood pressure measurements in patients with severe ischaemia

    DEFF Research Database (Denmark)

    Paaske, William; Tønnesen, K H

    1980-01-01

    The clinical course was followed and the ankle and toe blood pressures were measured with the strain gauge technique on 5 occasions during 2 years in 43 patients with pain at rest and/or ischaemic ulceration due to severe ischaemia of the legs on the basis of occlusive arterial disease. Although...

  15. Does mean arterial blood pressure scale with body mass in mammals?

    DEFF Research Database (Denmark)

    Poulsen, C B; Wang, T; Assersen, K

    2018-01-01

    For at least the last 30 years, it has been discussed whether mean arterial blood pressure (MAP) is independent of body mass or whether it increases in accordance with the vertical height between the heart and the brain. The debate has centred on the most appropriate mathematical models for analy......For at least the last 30 years, it has been discussed whether mean arterial blood pressure (MAP) is independent of body mass or whether it increases in accordance with the vertical height between the heart and the brain. The debate has centred on the most appropriate mathematical models......-Altman analysis showed a bias of 1 mm Hg with 95% confidence interval (from -35 to 36 mm Hg); that is, the limits of agreement between radiotelemetric studies and studies in restrained animals were double the supposed difference in the MAP between the mouse and elephant. In conclusion, the existing literature...

  16. Impact on early and late mortality after blood transfusion in coronary artery bypass graft surgery.

    Science.gov (United States)

    Santos, Antonio Alceu dos; Sousa, Alexandre Gonçalves; Thomé, Hugo Oliveira de Souza; Machado, Roberta Longo; Piotto, Raquel Ferrari

    2013-03-01

    To assess the 30-day and 1-year mortality associated to the red blood cell transfusion after coronary artery bypass grafting surgery. This procedure has been questioned by the international medical community, but it is still widely used in cardiac surgery. Therefore, it is needed more evidence of this medical practice in our country. We retrospectively analyzed 3,004 patients who underwent coronary artery bypass grafting surgery between June 2009 and July 2010. Patients were divided into two groups: non-transfused and transfused. The transfused group totaled 1,888 (63%) and non-transfused 1,116 (37%). There were 129 deaths in 30 days, with 108 (84%) in the transfused group and 21 (16%) in the non-transfused (Pconservation strategies should be encouraged to reduce blood products transfusions.

  17. Automated artery-venous classification of retinal blood vessels based on structural mapping method

    Science.gov (United States)

    Joshi, Vinayak S.; Garvin, Mona K.; Reinhardt, Joseph M.; Abramoff, Michael D.

    2012-03-01

    Retinal blood vessels show morphologic modifications in response to various retinopathies. However, the specific responses exhibited by arteries and veins may provide a precise diagnostic information, i.e., a diabetic retinopathy may be detected more accurately with the venous dilatation instead of average vessel dilatation. In order to analyze the vessel type specific morphologic modifications, the classification of a vessel network into arteries and veins is required. We previously described a method for identification and separation of retinal vessel trees; i.e. structural mapping. Therefore, we propose the artery-venous classification based on structural mapping and identification of color properties prominent to the vessel types. The mean and standard deviation of each of green channel intensity and hue channel intensity are analyzed in a region of interest around each centerline pixel of a vessel. Using the vector of color properties extracted from each centerline pixel, it is classified into one of the two clusters (artery and vein), obtained by the fuzzy-C-means clustering. According to the proportion of clustered centerline pixels in a particular vessel, and utilizing the artery-venous crossing property of retinal vessels, each vessel is assigned a label of an artery or a vein. The classification results are compared with the manually annotated ground truth (gold standard). We applied the proposed method to a dataset of 15 retinal color fundus images resulting in an accuracy of 88.28% correctly classified vessel pixels. The automated classification results match well with the gold standard suggesting its potential in artery-venous classification and the respective morphology analysis.

  18. The gated blood pool scan in the evaluation of coronary artery disease

    International Nuclear Information System (INIS)

    Anger, K.; Erbel, R.; Krebs, W.; Meyer, J.; Moeller, T.; Schweizer, P.; Yalkinoglu, O.; Technische Hochschule Aachen

    1983-01-01

    38 patients with clinically suspected coronary artery disease were studied by contrast ventriculography, 2-dimensional echocardiography and multiple gated blood pool imaging (MUGA) without stress. The results were compared with eath other and with the final diagnosis confirmed by coronary angiography. The left ventricular ejection fraction is evaluated nearly identically and with sufficient accuracy by both non-invasive methods, local motion abnormalities are on the other hand diagnosed in the best way by MUGA imaging in our own cases. (orig.) [de

  19. Relationship between regional myocardial blood flow and thallium-201 distribution in the presence of coronary artery stenosis and dipyridamole-induced vasodilation

    International Nuclear Information System (INIS)

    Mays, A.E. Jr.; Cobb, F.R.

    1984-01-01

    This study assesses the relationship between the distribution of thallium-201 and myocardial blood flow during coronary vasodilation induced by intravenous dipyridamole in canine models of partial and complete coronary artery stenosis. 10 dogs were chronically instrumented with catheters in the left atrium and aorta and with a balloon occluder and electromagnetic flow probe on the proximal left circumflex coronary artery. Regional myocardial blood flow was measured during control conditions with radioisotope-labeled microspheres, and the phasic reactive hyperemic response to a 20-s transient occlusion was then recorded. Dipyridamole was then infused intravenously until phasic coronary blood flow increased to match peak hyperemic values. The left circumflex coronary artery was either partially occluded to reduce phasic blood flow to control values (group 1) or it was completely occluded (group 2), and thallium-201 and a second microsphere label were injected. 5 min later, the animals were sacrificed, the left ventricle was sectioned into 1-2-g samples, and thallium-201 activity and regional myocardial blood flow were measured. Curvilinear regression analyses between thallium-201 localization and myocardial blood flow during dipyridamole infusion demonstrated a slightly better fit to a second- as compared with a first-order model, indicating a slight roll-off of thallium activity as myocardial blood flow increases. During the dipyridamole infusion, the increases in phasic blood flow, the distributions of regional myocardial blood flow, and the relationships between thallium-201 localization and regional blood flow were comparable to values previously observed in exercising dogs with similar occlusions. These data provide basic validation that supports the use of intravenous dipyridamole and thallium-201 as an alternative to exercise stress and thallium-201 for evaluating the effects of coronary occlusive lesions on the distribution of regional myocardial blood flow

  20. Observational study comparing non-invasive blood pressure measurement at the arm and ankle during caesarean section.

    Science.gov (United States)

    Drake, M J P; Hill, J S

    2013-05-01

    Upper-arm non-invasive blood pressure measurement during caesarean section can be uncomfortable and unreliable because of movement artefact in the conscious parturient. We aimed to determine whether ankle blood pressure measurement could be used instead in this patient group by comparing concurrent arm and ankle blood pressure measured throughout elective caesarean section under regional anaesthesia in 64 term parturients. Bland-Altman analysis of mean difference (95% limits of agreement [range]) between the ankle and arm was 11.2 (-20.3 to +42.7 [-67 to +102]) mmHg for systolic arterial pressure, -0.5 (-21.0 to +19.9 [-44 to +91]) mmHg for mean arterial pressure and -3.8 (-25.3 to +17.8 [-41 to +94]) mmHg for diastolic arterial pressure. Although ankle blood pressure measurement is well tolerated and allows greater mobility of the arms than measurement from the arm, the degree of discrepancy between the two sites is unacceptable to allow routine use of ankle blood pressure measurement, especially for systolic arterial pressure. However, ankle blood pressure measurement may be a useful alternative in situations where arm blood pressure measurement is difficult or impossible. Anaesthesia © 2013 The Association of Anaesthetists of Great Britain and Ireland.

  1. Comparison of arterial and venous blood gases and the effects of analysis delay and air contamination on arterial samples in patients with chronic obstructive pulmonary disease and healthy controls.

    Science.gov (United States)

    O'Connor, T M; Barry, P J; Jahangir, A; Finn, C; Buckley, B M; El-Gammal, A

    2011-01-01

    Arterial blood gases (ABGs) are often sampled incorrectly, leading to a 'mixed' or venous sample. Delays in analysis and air contamination are common. We measured the effects of these errors in patients with chronic obstructive pulmonary disease (COPD) exacerbations and controls. Arterial and venous samples were analyzed from 30 patients with COPD exacerbation and 30 controls. Venous samples were analysed immediately and arterial samples separated into non-air-contaminated and air-contaminated specimens and analysed at 0, 30, 60, 90 and 180 min. Mean venous pH was 7.371 and arterial pH was 7.407 (p Air contamination was associated with a clinically significant increase in PO₂ in all samples, including those that were immediately analyzed. Arterial and venous pH differ significantly. Venous pH cannot accurately replace arterial pH. Temporal delays in ABG analysis result in a significant decline in measured pH. ABGs should be analysed within 30 min. Air contamination leads to an immediate increase in measured PO₂, indicating that air-contaminated ABGs should be discarded. Copyright © 2010 S. Karger AG, Basel.

  2. Diagnosis of arterial prosthetic graft infection by 111In oxine white blood cell scans

    International Nuclear Information System (INIS)

    McKeown, P.P.; Miller, D.C.; Jamieson, S.W.; Mitchell, R.S.; Reitz, B.A.; Olcott, C.; Mehigan, J.T.; Silberstein, R.J.; McDougall, I.R.

    1982-01-01

    Early and accurate diagnosis of infected prosthetic arterial grafts is difficult, despite the application of diverse diagnostic modalities. Delay in making the diagnosis is largely responsible for the high amputation and mortality rates associated with this complication. In nine patients with suspected graft infections, 111 In white blood cell scanning was useful and accurate. Graft infection was proved in five cases and ruled out in three. One false-positive scan was due to a sigmoid diverticular abscess overlying the graft. 111 In white blood cell scans may improve the accuracy of diagnosing infected prosthetic grafts, which may result in better limb and patient salvage rates

  3. Evaluation of wet cupping therapy on the arterial and venous blood parameters in healthy Arabian horses

    Directory of Open Access Journals (Sweden)

    Turke Shawaf

    2018-05-01

    Full Text Available Aim: Recently, the complementary therapies such as cupping and acupuncture are being used in veterinary medicine. This research was carried out to determine the effects of wet cupping therapy (Hijama on the hematological and the biochemical parameters in the healthy Arabian horses for the first time. Materials and Methods: In this study, seven clinically healthy Arabian horses were randomly selected. Four points on the animal body were selected to perform the cupping therapy. Two points were selected at the back just behind the scapula on the left and right sides; another two points were located in the rump. Cups with 4 oz (125 ml size with narrow mouths were used. A manual pump (sucking cups was used to create the negative pressure within the cups during cupping. Arterial and venous blood parameters and serum cortisol concentration were measured before cupping and 3 days and 2, 4, and 8 weeks after cupping. Results: No significant differences were estimated in most hematological and biochemical parameters after cupping. A significant decrease in the concentration of serum cortisol was observed in 3 and 14 days after cupping. Conclusion: Cupping induced minor changes on the hematological and biochemical parameters in Arabian horses. This is the first trial on the effects of wet cupping therapy on the different parameters in Arabian horses, which would be useful for further investigations on the role of complementary therapies in horses. Our further studies will include different disease models.

  4. Evaluation of wet cupping therapy on the arterial and venous blood parameters in healthy Arabian horses

    Science.gov (United States)

    Shawaf, Turke; El-Deeb, Wael; Hussen, Jamal; Hendi, Mahmoud; Al-Bulushi, Shahab

    2018-01-01

    Aim: Recently, the complementary therapies such as cupping and acupuncture are being used in veterinary medicine. This research was carried out to determine the effects of wet cupping therapy (Hijama) on the hematological and the biochemical parameters in the healthy Arabian horses for the first time. Materials and Methods: In this study, seven clinically healthy Arabian horses were randomly selected. Four points on the animal body were selected to perform the cupping therapy. Two points were selected at the back just behind the scapula on the left and right sides; another two points were located in the rump. Cups with 4 oz (125 ml) size with narrow mouths were used. A manual pump (sucking cups) was used to create the negative pressure within the cups during cupping. Arterial and venous blood parameters and serum cortisol concentration were measured before cupping and 3 days and 2, 4, and 8 weeks after cupping. Results: No significant differences were estimated in most hematological and biochemical parameters after cupping. A significant decrease in the concentration of serum cortisol was observed in 3 and 14 days after cupping. Conclusions: Cupping induced minor changes on the hematological and biochemical parameters in Arabian horses. This is the first trial on the effects of wet cupping therapy on the different parameters in Arabian horses, which would be useful for further investigations on the role of complementary therapies in horses. Our further studies will include different disease models.

  5. Arterial line pressure control enhanced extracorporeal blood flow prescription in hemodialysis patients

    Directory of Open Access Journals (Sweden)

    Rosales Laura

    2008-11-01

    Full Text Available Abstract Background In hemodialysis, extracorporeal blood flow (Qb recommendation is 300–500 mL/min. To achieve the best Qb, we based our prescription on dynamic arterial line pressure (DALP. Methods This prospective study included 72 patients with catheter Group 1 (G1, 1877 treatments and 35 arterio-venous (AV fistulae Group 2 (G2, 1868 treatments. The dialysis staff was trained to prescribe Qb sufficient to obtain DALP between -200 to -250 mmHg. We measured ionic clearance (IK: mL/min, access recirculation, DALP (mmHg and Qb (mL/min. Six prescription zones were identified: from an optimal A zone (Qb > 400, DALP -200 to -250 to zones with lower Qb E (Qb -199. Results Treatments distribution in A was 695 (37% in G1 vs. 704 (37.7% in G2 (P = 0.7. In B 150 (8% in G1 vs. 458 (24.5% in G2 (P P = 0.62. IK in A was 214 ± 34 (G1 vs. 213 ± 35 (G2 (P = 0.65. IK Anova between G2 zones was: A vs. C and D (P P = 0.02. Conclusion In conclusion, an optimal Qb can de prescribed with DALP of -200 mmHg. Staff adherence to DLAP treatment prescription could be reached up to 81.3% in catheters and 84.1% in AV fistulae.

  6. Doppler Flow Wire Evaluation of Renal Blood Flow Reserve in Hypertensive Patients with Normal Renal Arteries

    International Nuclear Information System (INIS)

    Beregi, Jean-Paul; Mounier-Vehier, Claire; Devos, Patrick; Gautier, Corinne; Libersa, Christian; McFadden, Eugene P.; Carre, Alain

    2000-01-01

    Purpose: To study the vasomotor responses of the renal microcirculation in patients with essential hypertension.Methods: We studied the reactivity of the renal microcirculation to papaverine, with intraarterial Doppler and quantitative arteriography, in 34 renal arteries of 19 hypertensive patients without significant renal artery stenosis. Isosorbide dinitrate was given to maximally dilate proximal renal arteries. APV (average peak blood flow velocity) was used as an index of renal blood flow.Results: Kidneys could be divided into two distinct subgroups based on their response to papaverine. An increase in APV of up to 55% occurred in 21 kidneys, an increase > 55% in 13 kidneys. Within each group the values were normally distributed. Both baseline APV and the effect of papaverine on mean velocity differed significantly between groups.Conclusion: There seems to be a subgroup of patients with essential hypertension that has an impaired reactivity to papaverine, consistent with a functional impairment of the renal microcirculation. Further studies are required to determine whether this abnormality contributes to or results from elevated blood pressure

  7. Arterial Blood Supply to the Spinal Cord in Animal Models of Spinal Cord Injury. A Review.

    Science.gov (United States)

    Mazensky, David; Flesarova, Slavka; Sulla, Igor

    2017-12-01

    Animal models are used to examine the results of experimental spinal cord injury. Alterations in spinal cord blood supply caused by complex spinal cord injuries contribute significantly to the diversity and severity of the spinal cord damage, particularly ischemic changes. However, the literature has not completely clarified our knowledge of anatomy of the complex three-dimensional arterial system of the spinal cord in experimental animals, which can impede the translation of experimental results to human clinical applications. As the literary sources dealing with the spinal cord arterial blood supply in experimental animals are limited and scattered, the authors performed a review of the anatomy of the arterial blood supply to the spinal cord in several experimental animals, including pigs, dogs, cats, rabbits, guinea pigs, rats, and mice and created a coherent format discussing the interspecies differences. This provides researchers with a valuable tool for the selection of the most suitable animal model for their experiments in the study of spinal cord ischemia and provides clinicians with a basis for the appropriate translation of research work to their clinical applications. Anat Rec, 300:2091-2106, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  8. Two-Fluid Mathematical Models for Blood Flow in Stenosed Arteries: A Comparative Study

    Directory of Open Access Journals (Sweden)

    Sankar DS

    2009-01-01

    Full Text Available The pulsatile flow of blood through stenosed arteries is analyzed by assuming the blood as a two-fluid model with the suspension of all the erythrocytes in the core region as a non-Newtonian fluid and the plasma in the peripheral layer as a Newtonian fluid. The non-Newtonian fluid in the core region of the artery is assumed as a (i Herschel-Bulkley fluid and (ii Casson fluid. Perturbation method is used to solve the resulting system of non-linear partial differential equations. Expressions for various flow quantities are obtained for the two-fluid Casson model. Expressions of the flow quantities obtained by Sankar and Lee (2006 for the two-fluid Herschel-Bulkley model are used to get the data for comparison. It is found that the plug flow velocity and velocity distribution of the two-fluid Casson model are considerably higher than those of the two-fluid Herschel-Bulkley model. It is also observed that the pressure drop, plug core radius, wall shear stress and the resistance to flow are significantly very low for the two-fluid Casson model than those of the two-fluid Herschel-Bulkley model. Hence, the two-fluid Casson model would be more useful than the two-fluid Herschel-Bulkley model to analyze the blood flow through stenosed arteries.

  9. Relationship between haemodynamic impairment and collateral blood flow in carotid artery disease.

    Science.gov (United States)

    Hartkamp, Nolan S; Petersen, Esben T; Chappell, Michael A; Okell, Thomas W; Uyttenboogaart, Maarten; Zeebregts, Clark J; Bokkers, Reinoud Ph

    2017-01-01

    Collateral blood flow plays a pivotal role in steno-occlusive internal carotid artery (ICA) disease to prevent irreversible ischaemic damage. Our aim was to investigate the effect of carotid artery disease upon cerebral perfusion and cerebrovascular reactivity and whether haemodynamic impairment is influenced at brain tissue level by the existence of primary and/or secondary collateral. Eighty-eight patients with steno-occlusive ICA disease and 29 healthy controls underwent MR examination. The presence of collaterals was determined with time-of-flight, two-dimensional phase contrast MRA and territorial arterial spin labeling (ASL) imaging. Cerebral blood flow and cerebrovascular reactivity were assessed with ASL before and after acetazolamide. Cerebral haemodynamics were normal in asymptomatic ICA stenosis patients, as opposed to patients with ICA occlusion, in whom the haemodynamics in both hemispheres were compromised. Haemodynamic impairment in the affected brain region was always present in symptomatic patients. The degree of collateral blood flow was inversely correlated with haemodynamic impairment. Recruitment of secondary collaterals only occurred in symptomatic ICA occlusion patients. In conclusion, both CBF and cerebrovascular reactivity were found to be reduced in symptomatic patients with steno-occlusive ICA disease. The presence of collateral flow is associated with further haemodynamic impairment. Recruitment of secondary collaterals is associated with severe haemodynamic impairment.

  10. Effects of two newly synthesized analogues of lidocaine on rat arterial blood pressure and heart rate.

    Science.gov (United States)

    Al Rasheed, N M; Al Sayed, M I; Al Zuhair, H H; Al Obaid, A R; Fatani, A J

    2001-04-01

    Two new analogues of lidocaine were synthesized at the College of Pharmacy, King Saud University: compound I (Methyl-2-[2-(N,N-diethylamino) acetamido]-3-cyano-4,5-dimethylbenzoate) and compound II (Methyl-2-[2-(piperidino) acetamido]-3-cyano-4,5-dimethylbenzoate). Their influence on the arterial blood pressure and the heart rate of urethane-anaesthetized rats was studied and compared with the actions of lidocaine. Compounds I, II and lidocaine induced significant dose-dependent decreases in the arterial blood pressure and heart rate, which usually returned to basal values within 3-5 min. There were significant differences in the potency of the three compounds in producing their effects on blood pressure and heart rate (Plidocaine and compound I, respectively. The results of this study also indicated the ineffectiveness of antagonists of autonomic, histaminergic and 5-HT receptor, and various vasodilators in blocking the actions of the three compounds on blood pressure and heart rate. Pretreatment with CaCl(2)significantly reduced the hypotension and bradycardia induced by the three compounds, suggesting the involvement of calcium channels, probably of the L type. Several possible mechanisms are postulated. In conclusion, the results direct attention to the capability of the two new compounds to decrease blood pressure and heart rate; affects that may have clinical potential. Copyright 2001 Academic Press.

  11. Reduced peripheral arterial blood flow with preserved cardiac output during submaximal bicycle exercise in elderly heart failure

    Directory of Open Access Journals (Sweden)

    Leng Xiaoyan

    2009-11-01

    Full Text Available Abstract Background Older heart failure (HF patients exhibit exercise intolerance during activities of daily living. We hypothesized that reduced lower extremity blood flow (LBF due to reduced forward cardiac output would contribute to submaximal exercise intolerance in older HF patients. Methods and Results Twelve HF patients both with preserved and reduced left ventricular ejection fraction (LVEF (aged 68 ± 10 years without large (aorta or medium sized (iliac or femoral artery vessel atherosclerosis, and 13 age and gender matched healthy volunteers underwent a sophisticated battery of assessments including a peak exercise oxygen consumption (peak VO2, b physical function, c cardiovascular magnetic resonance (CMR submaximal exercise measures of aortic and femoral arterial blood flow, and d determination of thigh muscle area. Peak VO2 was reduced in HF subjects (14 ± 3 ml/kg/min compared to healthy elderly subjects (20 ± 6 ml/kg/min (p = 0.01. Four-meter walk speed was 1.35 ± 0.24 m/sec in healthy elderly verses 0.98 ± 0.15 m/sec in HF subjects (p p ≤ 0.03. Conclusion During CMR submaximal bike exercise in the elderly with heart failure, mechanisms other than low cardiac output are responsible for reduced lower extremity blood flow.

  12. Gradient changes in porcine renal arterial vascular anatomy and blood flow after cryoablation.

    Science.gov (United States)

    Lagerveld, Brunolf W; van Horssen, Pepijn; Laguna, M Pilar; van den Wijngaard, Jeroen P H M; Siebes, Maria; Wijkstra, Hessel; de la Rosette, Jean J M C H; Spaan, Jos A E

    2011-08-01

    We quantified temporal changes in vascular structure and blood flow after cryosurgery of the porcine kidney in vivo. We studied 5 groups of 4 kidneys each with a survival time of 20 minutes, 4 hours, 2 days, and 1 and 2 weeks after cryoablation, respectively. Before harvesting the kidneys, fluorescently labeled microspheres were administrated in the descending aorta. After harvest the kidney and its vasculature were casted with fluorescently dyed elastomer, frozen and processed in an imaging cryomicrotome to reveal the 3-dimensional arterial branching structure and microsphere distribution. In regions of interest vessels were segmented by image analysis software and histograms were constructed to reveal the total summed vessel length as a function of diameter. A characteristic diameter of the ablated area was measured. The 20-minute survival group histograms showed a significant shift of the peak to larger diameters (p<0.002), indicating that smaller vessels were destroyed. Microsphere density was decreased to 2% in the ablated region but not in the nonablated border zone, depending on the remaining crater crossing larger vessels. After 2 weeks neither vessels nor microspheres were left in the ablated area, which had shrunk by about 40% in diameter. Study limitations are the lack of histological confirmation and the use of normal rather than cancerous tissue. Larger vessels remain patent just after ablation and transport blood to the border of the ablation crater but perfusion within the crater is halted instantly. Characteristic crater diameter increases initially but decreases thereafter. Destruction of vessels and tissue is complete 2 weeks after cryoablation. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  13. Development of a Duplex Ultrasound Simulator and Preliminary Validation of Velocity Measurements in Carotid Artery Models.

    Science.gov (United States)

    Zierler, R Eugene; Leotta, Daniel F; Sansom, Kurt; Aliseda, Alberto; Anderson, Mark D; Sheehan, Florence H

    2016-07-01

    Duplex ultrasound scanning with B-mode imaging and both color Doppler and Doppler spectral waveforms is relied upon for diagnosis of vascular pathology and selection of patients for further evaluation and treatment. In most duplex ultrasound applications, classification of disease severity is based primarily on alterations in blood flow velocities, particularly the peak systolic velocity (PSV) obtained from Doppler spectral waveforms. We developed a duplex ultrasound simulator for training and assessment of scanning skills. Duplex ultrasound cases were prepared from 2-dimensional (2D) images of normal and stenotic carotid arteries by reconstructing the common carotid, internal carotid, and external carotid arteries in 3 dimensions and computationally simulating blood flow velocity fields within the lumen. The simulator displays a 2D B-mode image corresponding to transducer position on a mannequin, overlaid by color coding of velocity data. A spectral waveform is generated according to examiner-defined settings (depth and size of the Doppler sample volume, beam steering, Doppler beam angle, and pulse repetition frequency or scale). The accuracy of the simulator was assessed by comparing the PSV measured from the spectral waveforms with the true PSV which was derived from the computational flow model based on the size and location of the sample volume within the artery. Three expert examiners made a total of 36 carotid artery PSV measurements based on the simulated cases. The PSV measured by the examiners deviated from true PSV by 8% ± 5% (N = 36). The deviation in PSV did not differ significantly between artery segments, normal and stenotic arteries, or examiners. To our knowledge, this is the first simulation of duplex ultrasound that can create and display real-time color Doppler images and Doppler spectral waveforms. The results demonstrate that an examiner can measure PSV from the spectral waveforms using the settings on the simulator with a mean absolute error

  14. [Evaluation and Optimization of Microvascular Arterial Anastomoses by Transit Time Flow Measurement].

    Science.gov (United States)

    Herberhold, S; Röttker, J; Bartmann, D; Solbach, A; Keiner, S; Welz, A; Bootz, F; Laffers, W

    2016-03-01

    INDRODUCTION: The regular application of transit time flow measurement in microvascular anastomoses during heart surgery has lead to improvements of the outcome of coronary artery bypass grafts. Our study was meant to discover whether this measurement method was also applicable for evaluation and optimization of microvascular arterial anastomoses of radial forearm flaps. In this prospective examination a combining ultrasound imaging and transit time flow measurement device (VeriQ, MediStim) was used during surgery to assess anastomotic quality of 15 radial forearm flaps. Pulsatility index (PI) and mean blood flow were measured immediately after opening the arterial anastomosis as well as 15 min afterwards. Furthermore, application time and description of handling were recorded seperately for every assessment. Mean blood flow immediately after opening the anastomosis and 15 min later were 3.9 and 3.4 ml/min resepectively showing no statistically significant difference (p=0.96). There was no significance in the increase of pulsatility index from 22.1 to 27.2 (p=0.09) during the same time range, either. Due to measurement results showing atypical pulse curves in 2 cases decision for surgical revision of the anastomoses was made. All forearm flaps showed good vascularisation during follow-up. Time for device set up, probe placement and measurements was about 20 min. Handling was described to be uncomplicated without exception. There were no noteworthy problems. Transit time flow measurement contributes to the improvement of anastomotic quality and therefore to the overall outcome of radial forearm flaps. The examined measurement method provides objective results and is useful for documentation purposes. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Radioimmunological determination of 5a-pregnane-3,20-dione and progesterone in arterial and venous blood from the umbilical cord

    International Nuclear Information System (INIS)

    Tannich, E.

    1985-01-01

    Radioimmunological investigations of arterial and venous blood from the umbilical cord for 5a-DHP and progesterone were carried out in 60 newly delivered infants using 3 H as a tracer substance. The following findings were revealed: 1) The correlation between progesterone and 5a-DHP was better in the venous blood than in the arterial blood from the umbilical cord and the concentrations measured for the two hormones were higher in the vein. 2) Both the umbilical vein and artery showed more elevated hormone levels in male infants as compared to female infants. 3) The duration of gestation, the concentration of hydrogen ions in the fetal plasma and various other maternal and fetal factors have an influence on the height of the 5a-DHP and progesterone levels in the umbilical blood. This was also concluded from the fact that the (arterial and venous) hormone concentrations measured in infants from primiparae were higher than those in infants from multiparae. The metabolisation of 5a-DHP varies between the sexes, which does not hold true for progosterone. (TRV) [de

  16. Soybean oil increases SERCA2a expression and left ventricular contractility in rats without change in arterial blood pressure

    Directory of Open Access Journals (Sweden)

    Vassallo Dalton

    2010-05-01

    Full Text Available Abstract Background Our aim was to evaluate the effects of soybean oil treatment for 15 days on arterial and ventricular pressure, myocardial mechanics and proteins involved in calcium handling. Methods Wistar rats were divided in two groups receiving 100 μL of soybean oil (SB or saline (CT i.m. for 15 days. Ventricular performance was analyzed in male 12-weeks old Wistar rats by measuring left ventricle diastolic and systolic pressure in isolated perfused hearts according to the Langendorff technique. Protein expression was measured by Western blot analysis. Results Systolic and diastolic arterial pressures did not differ between CT and SB rats. However, heart rate was reduced in the SB group. In the perfused hearts, left ventricular isovolumetric systolic pressure was higher in the SB hearts. The inotropic response to extracellular Ca2+ and isoproterenol was higher in the soybean-treated animals than in the control group. Myosin ATPase and Na+-K+ATPase activities, the expression of sarcoplasmic reticulum calcium pump (SERCA2a and sodium calcium exchanger (NCX were increased in the SB group. Although the phosfolamban (PLB expression did not change, its phosphorylation at Ser16 was reduced while the SERCA2a/PLB ratio was increased. Conclusions In summary, soybean treatment for 15 days in rats increases the left ventricular performance without affecting arterial blood pressure. These changes might be associated with an increase in the myosin ATPase activity and SERCA2a expression.

  17. Cerebral blood flow and cerebrovascular reserve capacity in patients with occlusion or severe stenosis of cerebral arterial trunk

    Energy Technology Data Exchange (ETDEWEB)

    Yoshinaga, Shinya; Tanaka, Akira; Nakayama, Yoshiya; Tomonaga, Masamichi [Fukuoka Univ., Chikushino (Japan). Chikushi Hospital

    1997-12-01

    The cerebral blood flow (CBF) and the cerebrovascular reserve capacity (CVRC) were sequentially measured using a xenon enhanced CT scan in patients with transient ischemic attack or minor stroke due to an occlusion or a severe stenosis of the cerebral arterial trunk. The patients consisted of twelve males and one female ranging from 37 to 71 years of age (53 years on average). The vascular lesion was located in the internal carotid artery (7 patients) and in the middle cerebral artery (6 patients). Eleven patients received antiplatelet drug therapy, while two other patients underwent STA-MCA anastomosis. The CBF measurements were initially done within one month after the attack and then from 6 to 24 months (12 months on average) after the first study. Only one of 13 patients demonstrated a reattack during the period of observation and the CVRC decreased to 0% from the 14% level observed prior to the reattack, although the CBF was preserved. In the other twelve patients without a reattack, the CVRC was found to improve to 29.4% from 9.9% with statistical significance, even though the CBF remained the same in the first study. This study suggests hemodynamic insult to be closely related to the decreased in the CVRC, while STA-MCA anastomosis does not for prevent hemodynamic reattack based on a decrease in the CVRC in the early stage. (author)

  18. Measurement of pulmonary vascular resistance of Fontan candidates with pulmonary arterial distortion by means of pulmonary perfusion imaging

    International Nuclear Information System (INIS)

    Park, In-Sam; Mizukami, Ayumi; Tomimatsu, Hirofumi; Kondou, Chisato; Nakanishi, Toshio; Nakazawa, Makoto; Momma, Kazuo

    1998-01-01

    We measured the distribution of blood flow to the right (R) and left lung (L) by means of pulmonary perfusion imaging and calculated pulmonary vascular resistance (Rp) in 13 patients, whose right and left pulmonary artery pressures were different by 2 to 9 mmHg due to pulmonary arterial distortion (5 interruption, 8 stenosis). The right lung/left lung blood flow ratio was determined and from the ratio and the total pulmonary blood flow, which was determined using the Fick's principle, the absolute values of right and left pulmonary blood flow were calculated. Using the right and left pulmonary blood flow and the right and left pulmonary arterial pressures, right and left pulmonary vascular resistance were calculated, separately. Vascular resistance of the whole lung (Rp) was then calculated using the following equation. 1/(Rp of total lung)=1/(Rp of right lung)+1/(Rp of left lung). Rp calculated from this equation was 1.8+/-0.8 U·m 2 and all values were less than 3 U·m 2 (range 0.3-2.8). Rp estimated from the conventional method using the total pulmonary blood flow and pulmonary arterial pressures, without using the right/left blood flow ratio, ranging from 0.4 to 3.8 U·m 2 and 5 of 13 patients showed Rp>3 U·m 2 . All patients underwent Fontan operation successfully. These data indicated that this method is useful to estimate Rp and to determine the indication of Fontan operation in patients with pulmonary arterial distortions. (author)

  19. Pulse Oximeter Derived Blood Pressure Measurement in Patients With a Continuous Flow Left Ventricular Assist Device.

    Science.gov (United States)

    Hellman, Yaron; Malik, Adnan S; Lane, Kathleen A; Shen, Changyu; Wang, I-Wen; Wozniak, Thomas C; Hashmi, Zubair A; Munson, Sarah D; Pickrell, Jeanette; Caccamo, Marco A; Gradus-Pizlo, Irmina; Hadi, Azam

    2017-05-01

    Currently, blood pressure (BP) measurement is obtained noninvasively in patients with continuous flow left ventricular assist device (LVAD) by placing a Doppler probe over the brachial or radial artery with inflation and deflation of a manual BP cuff. We hypothesized that replacing the Doppler probe with a finger-based pulse oximeter can yield BP measurements similar to the Doppler derived mean arterial pressure (MAP). We conducted a prospective study consisting of patients with contemporary continuous flow LVADs. In a small pilot phase I inpatient study, we compared direct arterial line measurements with an automated blood pressure (ABP) cuff, Doppler and pulse oximeter derived MAP. Our main phase II study included LVAD outpatients with a comparison between Doppler, ABP, and pulse oximeter derived MAP. A total of five phase I and 36 phase II patients were recruited during February-June 2014. In phase I, the average MAP measured by pulse oximeter was closer to arterial line MAP rather than Doppler (P = 0.06) or ABP (P < 0.01). In phase II, pulse oximeter MAP (96.6 mm Hg) was significantly closer to Doppler MAP (96.5 mm Hg) when compared to ABP (82.1 mm Hg) (P = 0.0001). Pulse oximeter derived blood pressure measurement may be as reliable as Doppler in patients with continuous flow LVADs. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Fourier Analysis of Peripheral Blood Pressure and Flow in Intraoperative Assessment of Infrainguinal Arterial Reconstructions

    Directory of Open Access Journals (Sweden)

    Cheshmedzhiev Mihail V.

    2014-08-01

    Full Text Available AIM: To assess infrainguinal arterial reconstructions by intraoperative flowmetry under the distal anastomosis using a fast Fourier transformation; calculate and compare the amplitude ratios of peripheral arterial blood pressure and volume flow before and after drug-induced vasodilation of occluded bypass grafts and bypass grafts that have been patent at least for 1 year. To find what magnitude of the change of these ratios indicate a long-term patency of the bypass grafting. PATIENTS AND METHODS: We compared the results of the intraoperative flowmetry tests of 97 patients with infrainguinal arterial reconstructions. The patients were divided into two groups based on the graft status: the grafts in 49 patients were patent for at least a year, and 48 patients had failed bypass. We used a fast Fourier transform (FFT of the pressure and blood flow waves and compared the ratios of their amplitudes before and after administration of a vasodilator drug into the graft. Comparing the ratios obtained before and those after administration of the drug we quantified their change in each group and analysed them. RESULTS: After a drug-induced vasodilation, the blood pressure and flow amplitude ratios for the group with compromised reconstructions were less than 1.9 times smaller than those before drug infusion, while for the group with bypass grafts that had been functional for at least 12 months the ratios declined by more than 1.9≈2 times. CONCLUSION: The magnitude of the change of amplitude ratios of the peripheral pressure and volume flow after drug-induced vasodilation can be used to make an assessment of the bypass graft and the distal arterial segment.

  1. Measurement of the arterial concentration of Gd-DTPA using MRI: a step toward quantitative perfusion imaging

    DEFF Research Database (Denmark)

    Fritz-Hansen, T; Rostrup, Egill; Larsson, H B

    1996-01-01

    A noninvasive method using an inversion recovery turbo-FLASH for dynamic measurement of the arterial input function represented by the bolus passage of Gd-DTPA in the descending aorta is presented, and the results are compared with the input function obtained by arterial blood samples. A good...... accordance between the two input functions was found, indicating that it is possible to measure the input function to the myocardium using MRI. A variation between the two concentration curves of 5% at upslope, 2.7% at peak point, and ... inversion time peak concentration....

  2. QUANTITATIVE CHANGES IN REGIONAL CEREBRAL BLOOD FLOW INDUCED BY COLD, HEAT AND ISCHEMIC PAIN: A CONTINUOUS ARTERIAL SPIN LABELING STUDY

    Science.gov (United States)

    Frölich, Michael A.; Deshpande, Hrishikesh; Ness, Timothy; Deutsch, Georg

    2012-01-01

    Background The development of arterial spin labeling methods, has allowed measuring regional cerebral blood flow (rCBF) quantitatively and to show the pattern of cerebral activity associated with any state such as a sustained pain state or changes due to a neurotropic drug. Methods We studied the differential effects of three pain conditions in ten healthy subjects on a 3T scanner during resting baseline, heat, cold and ischemic pain using continuous arterial spin labeling. Results Cold pain showed the greatest absolute rCBF increases in left anterior cingulate cortex, left amygdala, left angular gyrus, and Brodmann Area 6, and a significant rCBF decrease in the cerebellum. Changes in rCBF were characteristic of the type of pain condition: cold and heat pain showed increases, while the ischemic condition showed a reduction in mean absolute gray matter flow compared to rest. An association of subjects’ pain tolerance and cerebral blood flow was noted. Conclusions The observation that quantitative rCBF changes are characteristic of the pain task employed and that there is a consistent rCBF change in Brodman area 6, an area responsible for the integration of a motor response to pain, should provide extremely useful information in the quest to develop an imaging biomarker of pain. Conceivably, response in BA6 may serve as an objective measure of analgesic efficacy. PMID:22913924

  3. Quantitative changes in regional cerebral blood flow induced by cold, heat and ischemic pain: a continuous arterial spin labeling study.

    Science.gov (United States)

    Frölich, Michael A; Deshpande, Hrishikesh; Ness, Timothy; Deutsch, Georg

    2012-10-01

    The development of arterial spin labeling methods has allowed measuring regional cerebral blood flow (rCBF) quantitatively and to show the pattern of cerebral activity associated with any state such as a sustained pain state or changes due to a neurotropic drug. The authors studied the differential effects of three pain conditions in 10 healthy subjects on a 3 Tesla scanner during resting baseline, heat, cold, and ischemic pain using continuous arterial spin labeling. Cold pain showed the greatest absolute rCBF increases in left anterior cingulate cortex, left amygdala, left angular gyrus, and Brodmann area 6, and a significant rCBF decrease in the cerebellum. Changes in rCBF were characteristic of the type of pain condition: cold and heat pain showed increases, whereas the ischemic condition showed a reduction in mean absolute gray matter flow compared with rest. An association of subjects' pain tolerance and cerebral blood flow was noted. The observation that quantitative rCBF changes are characteristic of the pain task used and that there is a consistent rCBF change in Brodman area 6, an area responsible for the integration of a motor response to pain, should provide extremely useful information in the quest to develop an imaging biomarker of pain. Conceivably, response in BA6 may serve as an objective measure of analgesic efficacy.

  4. Hemoglobin, hematocrit, and changes in cerebral blood flow: the Second Manifestations of ARTerial disease-Magnetic Resonance study.

    Science.gov (United States)

    van der Veen, Pieternella H; Muller, Majon; Vincken, Koen L; Westerink, Jan; Mali, Willem P T M; van der Graaf, Yolanda; Geerlings, Mirjam I

    2015-03-01

    Hemoglobin and hematocrit are important determinants of blood viscosity and arterial oxygen content and may therefore influence cerebral blood flow (CBF). We examined cross-sectional and prospective associations of hemoglobin and hematocrit with CBF in 569 patients with manifest arterial disease (mean age 57 ± 10 years) with available data on magnetic resonance angiography to measure parenchymal CBF. Mean (SD) parenchymal CBF at baseline was 52.3 (9.8) mL/min/100 mL and decreased with 1.5 (11.0) mL/min/100 mL after on average 3.9 years of follow-up. Linear regression analyses showed that greater hemoglobin and hematocrit values were associated with lower baseline parenchymal CBF and more decline in parenchymal CBF over time, independent of cardiovascular risk factors, use of antiplatelet drugs, anticoagulants, or diuretics, and brain measures: adjusted mean differences (95% confidence interval [CI]) in decline in parenchymal CBF between patients in the lower and upper quartiles of hemoglobin and hematocrit were -2.48 (95% CI -3.70 to -1.25) and -3.69 (95% CI -5.45 to -1.94) mL/min/100 mL. Higher hemoglobin and hematocrit were associated with lower baseline parenchymal CBF and a greater decline in parenchymal CBF over time, possibly as a result of physiological compensating mechanisms. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Reliability of palpation of the radial artery compared with auscultation of the brachial artery in measuring SBP

    NARCIS (Netherlands)

    van der Hoeven, Niels V.; van den Born, Bert-Jan H.; van Montfrans, Gert A.

    2011-01-01

    Background Systolic blood pressure contributes more to cardiovascular disease than DBP, especially in elderly persons. Palpation of the radial artery to assess SBP - Riva-Rocci's technique-may be an attractive alternative for auscultatory SBP in these patients. Therefore, we investigated the

  6. Myocardial blood flow reserve is impaired in patients with aortic valve calcification and unobstructed epicardial coronary arteries.

    Science.gov (United States)

    Nel, Karen; Nam, Michael C Y; Anstey, Chris; Boos, Christopher J; Carlton, Edward; Senior, Roxy; Kaski, Juan Carlos; Khattab, Ahmed; Shamley, Delva; Byrne, Christopher D; Stanton, Tony; Greaves, Kim

    2017-12-01

    Although calcific aortic valve disease (CAVD) is associated with coronary atherosclerosis, it is not known whether early CAVD is associated with coronary microcirculatory dysfunction (CMD). We sought to investigate the relationship between myocardial blood flow reserve (MBFR) - a measure of CMD, and early CAVD in the absence of obstructive epicardial coronary artery disease. We also determined whether this relationship was independent of coronary artery disease (CAD) and hs-CRP, a marker of systemic inflammation. 183 patients with chest pain and unobstructed coronary arteries were studied. Aortic valve calcification score (AVCS), coronary total plaque length (TPL), and coronary calcium score were quantified from multislice CT. MBFR was assessed using vasodilator myocardial contrast echocardiography. Hs-CRP was measured from venous blood using a particle-enhanced immunoassay. Mean (±SD) participant age was 59.8 (9.6) years. Mean AVCS was 68 (258) AU, TPL was 15.6 (22.2) mm, and median coronary calcification score was 43.5AU. Mean MBFR was 2.20 (0.52). Mean hs-CRP was 2.52 (3.86) mg/l. Multivariable linear regression modelling incorporating demographics, coronary plaque characteristics, MBFR, and inflammatory markers, demonstrated that age (β=0.05, 95% CI: 0.02, 0.08, P=0.007), hs-CRP (β=0.09, CI: 0.02, 0.16, P=0.010) and diabetes (β=1.03, CI: 0.08, 1.98, P=0.033), were positively associated with AVCS. MBFR (β=-0.87, CI: -1.44, -0.30, P=0.003), BMI (β=-0.11, CI: -0.21, -0.01, P=0.033), and LDL (β=-0.32, CI: -0.61, -0.03, P=0.029) were negatively associated with AVCS. TPL and coronary calcium score were not independently associated with AVCS when included in the regression model. Coronary microvascular function as determined by measurement of myocardial blood flow reserve is independently associated with early CAVD. This effect is independent of the presence of coronary artery disease and also systemic inflammation. Copyright © 2017 Elsevier B.V. All rights

  7. Periodontal disease and inflammatory blood cytokines in patients with stable coronary artery disease

    Directory of Open Access Journals (Sweden)

    Cassio KAMPITS

    Full Text Available ABSTRACT Periodontal disease has been associated with elevations of blood cytokines involved in atherosclerosis in systemically healthy individuals, but little is known about this association in stable cardiovascular patients. The aim of this study was to assess the association between periodontal disease (exposure and blood cytokine levels (outcomes in a target population of patients with stable coronary artery disease (CAD. Material and Methods This cross-sectional study included 91 patients with stable CAD who had been under optimized cardiovascular care. Blood levels of IL-1β, IL-6, IL-8, IL-10, IFN-γ, and TNF-α were measured by Luminex technology. A full-mouth periodontal examination was conducted to record probing depth (PD and clinical attachment (CA loss. Multiple linear regression models, adjusting for gender, body mass index, oral hypoglycemic drugs, smoking, and occurre:nce of acute myocardial infarction were applied. Results CAD patients that experienced major events had higher concentrations of IFN-γ (median: 5.05 pg/mL vs. 3.01 pg/mL; p=0.01, IL-10 (median: 2.33 pg/mL vs. 1.01 pg/mL; p=0.03, and TNF-α (median: 9.17 pg/mL vs. 7.47 pg/mL; p=0.02. Higher numbers of teeth with at least 6 mm of CA loss (R2=0.07 and PD (R2=0.06 were significantly associated with higher IFN-γ log concentrations. Mean CA loss (R2=0.05 and PD (R2=0.06 were significantly related to IL-10 concentrations. Elevated concentrations of TNF-α were associated with higher mean CA loss (R2=0.07. Conclusion Periodontal disease is associated with increased systemic inflammation in stable cardiovascular patients. These findings provide additional evidence supporting the idea that periodontal disease can be a prognostic factor in cardiovascular patients.

  8. Measuring the arterial-induced skin vibration by geometrical moiré fringe

    Science.gov (United States)

    Chiu, Shih-Yung; Wang, Chun-Hsiung; Lee, Shu-Sheng; Wu, Wen-Jong; Hsu, Yu-Hsiang; Lee, Chih-Kung

    2018-02-01

    The demand for self-measured blood pressure self-monitoring device has much increased due to cardiovascular diseases have become leading causes of death for aging population. Currently, the primary non-invasive blood pressure monitoring method is cuff-based. It is well developed and accurate. However, the measuring process is not comfortable, and it cannot provide a continuous measurement. To overcome this problem, methods such as tonometry, volume clamp method, photoplethysmography, pulse wave velocity, and pulse transit time are reported. However, the limited accuracy hindered its application for diagnostics. To perform sequential blood pressure measurement with a high accuracy and long-term examination, we apply moiré interferometry to measure wrist skin vibration induced by radial artery. To achieve this goal, we developed a miniaturized device that can perform moiré interferometry around the wrist region. The 0.4-mm-pitched binary grating and tattoo sticker with 0.46 mm-pitched stripe pattern are used to perform geometric moiré. We demonstrated that the sensitivity and accuracy of this integrated system were sufficient to monitor arterialinduced skin vibration non-invasively. Our developed system was validated with ECG signals collected by a commercial system. According to our studies from measurement, the repeatability of wrist pulsation measurement was achieved with an accuracy of 99.1% in heart rate. A good repeatability of wrist pulse measurement was achieved. Simulations and experiments are both conducted in this paper and prove of geometrical moiré method a suitable technique for arterial-induced skin vibration monitoring.

  9. Wall morphology, blood flow and wall shear stress: MR findings in patients with peripheral artery disease

    Energy Technology Data Exchange (ETDEWEB)

    Galizia, Mauricio S.; Barker, Alex; Collins, Jeremy; Carr, James [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Liao, Yihua [Northwestern University' s Feinberg School of Medicine, Department of Preventive Medicine, Chicago, IL (United States); McDermott, Mary M. [Northwestern University' s Feinberg School of Medicine, Department of Preventive Medicine, Chicago, IL (United States); Northwestern University' s Feinberg School of Medicine, Department of Medicine, Chicago, IL (United States); Markl, Michael [Northwestern University, Department of Radiology, Feinberg School of Medicine, Chicago, IL (United States); Northwestern University, Department Biomedical Engineering, McCormick School of Engineering, Chicago, IL (United States)

    2014-04-15

    To investigate the influence of atherosclerotic plaques on femoral haemodynamics assessed by two-dimensional (2D) phase-contrast (PC) magnetic resonance imaging (MRI) with three-directional velocity encoding. During 1 year, patients with peripheral artery disease and an ankle brachial index <1.00 were enrolled. After institutional review board approval and written informed consent, 44 patients (age, 70 ± 12 years) underwent common femoral artery MRI. Patients with contra-indications for MRI were excluded. Sequences included 2D time-of-flight, proton-density, T1-weighted and T2-weighted MRI. Electrocardiogram (ECG)-gated 2D PC-MRI with 3D velocity encoding was acquired. A radiologist classified images in five categories. Blood flow, velocity and wall shear stress (WSS) along the vessel circumference were quantified from the PC-MRI data. The acquired images were of good quality for interpretation. There were no image quality problems related to poor ECG-gating or slice positioning. Velocities, oscillatory shear stress and total flow were similar between patients with normal arteries and wall thickening/plaque. Patients with plaques demonstrated regionally increased peak systolic WSS and enhanced WSS eccentricity. Combined multi-contrast morphological imaging of the peripheral arterial wall with PC-MRI with three-directional velocity encoding is a feasible technique. Further study is needed to determine whether flow is an appropriate marker for altered endothelial cell function, vascular remodelling and plaque progression. (orig.)

  10. Patient Specific Multiscale Simulations of Blood Flow in Coronary Artery Bypass Surgery

    Science.gov (United States)

    Bangalore Ramachandra, Abhay; Sankaran, Sethuraman; Kahn, Andrew M.; Marsden, Alison L.

    2013-11-01

    Coronary artery bypass surgery is performed to revascularize blocked coronary arteries in roughly 400,000 patients per year in the US.While arterial grafts offer superior patency, vein grafts are used in more than 70% of procedures, as most patients require multiple grafts. Vein graft failure (approx. 50% within 10 years) remains a major clinical issue. Mounting evidence suggests that hemodynamics plays a key role as a mechano-biological stimulus contributing to graft failure. However, quantifying relevant hemodynamic quantities (e.g. wall shear stress) invivo is not possible directly using clinical imaging techniques. We numerically compute graft hemodynamics in a cohort of 3-D patient specific models using a stabilized finite element method. The 3D flow domain is coupled to a 0D lumped parameter circulatory model. Boundary conditions are tuned to match patient specific blood pressures, stroke volumes & heart rates. Results reproduce clinically observed coronary flow waveforms. We quantify differences in multiple hemodynamic quantities between arterial & venous grafts & discuss possible correlations between graft hemodynamics & clinically observed graft failure.Such correlations will provide further insight into mechanisms of graft failure and may lead to improved clinical outcomes.

  11. The effects of hypotension on differences between the results of simultaneous venous and arterial blood gas analysis

    Directory of Open Access Journals (Sweden)

    Farhad Shirani

    2011-01-01

    Full Text Available Background: Analysis of venous blood gas (VBG can represent arterial blood gas (ABG analysis in patients with various diseases. The effects of hypotension on differences between the results of simultaneous venous and arterial blood gas analyses were reviewed. Methods: This observational, cross-sectional study was conducted from March to October 2010 in emergency depart-ments of two university hospitals in Tehran (Iran on consecutive adult patients for whom ABG had been indicated for diagnosis/treatment. Arterial and peripheral venous bloods were simultaneously sampled with blood pressure measure-ment. The VBG-ABG amount of difference regarding pH, HCO 3 , PCO 2 , PO 2 , SO 2 , and Base Excess (BE was com-pared between those with and without hypotension. Results: During the study, 192 patients (51.6 ± 23.6 years, 67.7% males were entered into the hypotension (n = 78 and normotensive groups (n = 114. The average VBG-ABG amount of difference (95% limits of agreement in the hypotension versus normotensive group were -0.030 (-0.09 to 0.03 vs. -0.016 (-0.1 to 0.068 for pH (p = 0.01, 1.79 (-1.91 to 5.49 vs. 1.32 (-1.94 to 4.58 mEq/L for HCO 3 (p = 0.032, 2.69 (-20.43 to 25.81 vs. 2.03 (-7.75 to 11.81 mmHg for PCO 2 (p = 0.295, -35.97 (-130.17 to 58.23 vs. -32.65 (-104.79 to 39.49 mmHg for PO 2 (p = 0.293, -18.58 (-14.66 to 51.82 vs. -9.06 (-31.28 to 13.16 percent (p < 0.001 for SO 2 , and 0.25 (-3.73 to 4.23 vs. 0.79 (-2.51 to 4.09 for BE (p = 0.036. Conclusions: Hypotensive status is associated with an increase in the amount of difference between VBG and ABG analysis regarding pH, HCO 3 , and BE, though the amount of increase does not seem to be clinically important. Studying the precise effects of replacing ABG with VBG on the clinical decision-making and the following outcomes is worth-while.

  12. Roles of myocardial blood volume and flow in coronary artery disease: an experimental MRI study at rest and during hyperemia

    International Nuclear Information System (INIS)

    McCommis, Kyle S.; Goldstein, Thomas A.; Pilgram, Thomas; Abendschein, Dana R.; Misselwitz, Bernd; Gropler, Robert J.; Zheng, Jie

    2010-01-01

    To validate fast perfusion mapping techniques in a setting of coronary artery stenosis, and to further assess the relationship of absolute myocardial blood volume (MBV) and blood flow (MBF) to global myocardial oxygen demand. A group of 27 mongrel dogs were divided into 10 controls and 17 with acute coronary stenosis. On 1.5-T MRI, first-pass perfusion imaging with a bolus injection of a blood-pool contrast agent was performed to determine myocardial perfusion both at rest and during either dipyridamole-induced vasodilation or dobutamine-induced stress. Regional values of MBF and MBV were quantified by using a fast mapping technique. Color microspheres and 99m Tc-labeled red blood cells were injected to obtain respective gold standards. Microsphere-measured MBF and 99m Tc-measured MBV reference values correlated well with the MR results. Given the same changes in MBF, changes in MBV are twofold greater with dobutamine than with dipyridamole. Under dobutamine stress, MBV shows better association with total myocardial oxygen demand than MBF. Coronary stenosis progressively reduced this association in the presence of increased stenosis severity. MR first-pass perfusion can rapidly estimate regional MBF and MBV. Absolute quantification of MBV may add additional information on stenosis severity and myocardial viability compared with standard qualitative clinical evaluations of myocardial perfusion. (orig.)

  13. Roles of myocardial blood volume and flow in coronary artery disease: an experimental MRI study at rest and during hyperemia

    Science.gov (United States)

    McCommis, Kyle S.; Goldstein, Thomas A.; Abendschein, Dana R.; Misselwitz, Bernd; Pilgram, Thomas; Gropler, Robert J.

    2010-01-01

    Objective To validate fast perfusion mapping techniques in a setting of coronary artery stenosis, and to further assess the relationship of absolute myocardial blood volume (MBV) and blood flow (MBF) to global myocardial oxygen demand. Methods A group of 27 mongrel dogs were divided into 10 controls and 17 with acute coronary stenosis. On 1.5-T MRI, first-pass perfusion imaging with a bolus injection of a blood-pool contrast agent was performed to determine myocardial perfusion both at rest and during either dipyridamole-induced vasodilation or dobutamine-induced stress. Regional values of MBF and MBV were quantified by using a fast mapping technique. Color microspheres and 99mTc-labeled red blood cells were injected to obtain respective gold standards. Results Microsphere-measured MBF and 99mTc-measured MBV reference values correlated well with the MR results. Given the same changes in MBF, changes in MBV are twofold greater with dobutamine than with dipyridamole. Under dobutamine stress, MBV shows better association with total myocardial oxygen demand than MBF. Coronary stenosis progressively reduced this association in the presence of increased stenosis severity. Conclusions MR first-pass perfusion can rapidly estimate regional MBF and MBV. Absolute quantification of MBV may add additional information on stenosis severity and myocardial viability compared with standard qualitative clinical evaluations of myocardial perfusion. PMID:20182731

  14. Roles of preoperative arterial blood gas tests in the surgical treatment of scoliosis with moderate or severe pulmonary dysfunction.

    Science.gov (United States)

    Liu, Jia-Ming; Shen, Jian-Xiong; Zhang, Jian-Guo; Zhao, Hong; Li, Shu-Gang; Zhao, Yu; Qiu, Giu-Xing

    2012-01-01

    It has been stated that preoperative pulmonary function tests are essential to assess the surgical risk in patients with scoliosis. Arterial blood gas tests have also been used to evaluate pulmonary function before scoliotic surgery. However, few studies have been reported. The aim of this study was to investigate the roles of preoperative arterial blood gas tests in the surgical treatment of scoliosis with moderate or severe pulmonary dysfunction. This study involved scoliotic patients with moderate or severe pulmonary dysfunction (forced vital capacity treatment between January 2002 and April 2010. A total of 73 scoliotic patients (23 males and 50 females) with moderate or severe pulmonary dysfunction were included. The average age of the patients was 16.53 years (ranged 10 - 44). The demographic distribution, medical records, and radiographs of all patients were collected. All patients received arterial blood gas tests and pulmonary function tests before surgery. The arterial blood gas tests included five parameters: partial pressure of arterial oxygen, partial pressure of arterial carbon dioxide, alveolar-arterial oxygen tension gradient, pH, and standard bases excess. The pulmonary function tests included three parameters: forced expiratory volume in 1 second ratio, forced vital capacity ratio, and peak expiratory flow ratio. All five parameters of the arterial blood gas tests were compared between the two groups with or without postoperative pulmonary complications by variance analysis. Similarly, all three parameters of the pulmonary function tests were compared. The average coronal Cobb angle before surgery was 97.42° (range, 50° - 180°). A total of 15 (20.5%) patients had postoperative pulmonary complications, including hypoxemia in 5 cases (33.3%), increased requirement for postoperative ventilatory support in 4 (26.7%), pneumonia in 2 (13.3%), atelectasis in 2 (13.3%), pneumothorax in 1 (6.7%), and hydrothorax in 1 (6.7%). No significant differences

  15. Effects of respiratory alkalosis and acidosis on myocardial blood flow and metabolism in patients with coronary artery disease.

    Science.gov (United States)

    Kazmaier, S; Weyland, A; Buhre, W; Stephan, H; Rieke, H; Filoda, K; Sonntag, H

    1998-10-01

    Variation of the arterial carbon dioxide partial pressure (PaCO2) is not uncommon in anesthetic practice. However, little is known about the myocardial consequences of respiratory alkalosis and acidosis, particularly in patients with coronary artery disease. The aim of the current study was to investigate the effects of variation in PaCO2 on myocardial blood flow (MBF), metabolism, and systemic hemodynamics in patients before elective coronary artery bypass graft surgery. In 10 male anesthetized patients, measurements of MBF, myocardial contractility, metabolism, and systemic hemodynamics were made in a randomized sequence at PaCO2 levels of 30, 40, and 50 mmHg, respectively. The MBF was measured using the Kety-Schmidt technique with argon as a tracer. End-diastolic left ventricular pressure and the maximal increase of left ventricular pressure were assessed using a manometer-tipped catheter. The cardiac index significantly changed with varying PaCO2 levels (hypocapnia, - 9%; hypercapnia, 13%). This reaction was associated with inverse changes in systemic vascular resistance index levels. The MBF significantly increased by 15% during hypercapnia, whereas no change was found during hypocapnia. Myocardial oxygen and glucose uptake and the maximal increase of left ventricular pressure were not affected by varying PaCO2 levels. In anesthetized patients with coronary artery disease, short-term variations in PaCO2 have significant effects on MBF but do not influence global myocardial oxygen and glucose uptake. Changes in systemic hemodynamics associated with respiratory alkalosis and acidosis are caused by changes in systemic vascular resistance rather than by alterations in myocardial contractility.

  16. The effects of stair climbing on arterial stiffness, blood pressure, and leg strength in postmenopausal women with stage 2 hypertension.

    Science.gov (United States)

    Wong, Alexei; Figueroa, Arturo; Son, Won-Mok; Chernykh, Oksana; Park, Song-Young

    2018-02-12

    Menopause is accompanied by a progressive arterial stiffening associated with increases in blood pressure (BP) and decline in muscular function. It is crucial to prevent or reduce the negative effects of menopause on vascular and muscular function by implementing appropriate lifestyle interventions, such as exercise training. We examined the effects of a stair climbing (SC) regimen on arterial stiffness (pulse wave velocity [PWV]), BP, and leg strength in postmenopausal women with stage 2 hypertension. Using a parallel experimental design, participants were randomly assigned to either SC (n = 21) or nonexercising control group (n = 20) for 12 weeks. Participants in the SC group trained 4 d/wk, climbing 192 steps 2 to 5 times/d. Participants' brachial-to-ankle PWV (baPWV), BP, and leg strength were measured at baseline and after 12 weeks of their assigned intervention. There was a significant group by time interaction (P hypertensive postmenopausal women. The decrease in arterial stiffness partially explained the improvements in SBP and leg strength. SC may be an effective intervention in the prevention and treatment of menopause/aging-related vascular complications and muscle weakness.

  17. Doppler ultrasonographic measurement of short-term effects of valsalva maneuver on retrobulbar blood flow.

    Science.gov (United States)

    Kimyon, Sabit; Mete, Ahmet; Mete, Alper; Mete, Duçem

    2017-11-12

    To investigate the effects of Valsalva maneuver (VM) on retrobulbar blood flow parameters in healthy subjects. Participants without any ophthalmologic or systemic pathology were examined in supine position with color and pulsed Doppler imaging for blood flow measurement, via a paraocular approach, in the ophthalmic artery (OA), central retinal artery (CRA), central retinal vein (CRV), nasal posterior ciliary artery (NPCA), and temporal posterior ciliary artery (TPCA), 10 seconds after a 35- to 40-mm Hg expiratory pressure was reached. Peak systolic velocity (PSV), end-diastolic velocity (EDV), pulsatility index (PI), and resistivity index (RI) values were recorded for each artery. PSV and EDV values were recorded for CRV. There were significant differences between resting and VM values of PSV and EDV of CRA, RI of NPCA, and PI, RI, and EDV of TPCA. Resting CRA-EDV, CRV-PSV, and CRV-EDV were positively correlated whereas resting OA-PSV and CRA-PI, and OA-PSV, CRA-PSV, and CRA-EDV during VM, were negatively correlated with age. VM induces a short-term increase in CRA blood flow and a decrease in NPCA and TPCA RI. Additional studies with a longer Doppler recording during VM, in a larger population sample, are required to allow definitive interpretation. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:551-555, 2017. © 2017 Wiley Periodicals, Inc.

  18. Dorsalis pedis arterial pressure is lower than noninvasive arm blood pressure in normotensive patients under sevoflurane anesthesia.

    Science.gov (United States)

    Chen, Yan; Wang, Enqin; Zhu, Yuan; Li, Yongshuai; Lu, Kaizhi

    2016-02-01

    It is widely known that blood pressure (BP) in the lower extremity is higher than in the upper extremity. However, whether this phenomenon remains the same during general anesthesia is still unclear. This study aims to investigate the difference between invasive dorsalis pedis artery (DPA) pressure and the most commonly used noninvasive arm pressure during sevoflurane anesthesia. A total of 50 normotensive Chinese patients were enrolled in this observational study. Invasive DPA pressure, noninvasive arm pressure, and systemic vascular resistance index were assessed simultaneously. BP data during the entire surgery were analyzed through a Bland-Altman plot for repeated measures. The concordance of BP variation in the DPA and the arm was analyzed using four-quadrant plots and linear regression. The time-dependent changes in BP and the systemic vascular resistance index were also evaluated. Data from 46 effective cases were analyzed. Bias (95% limits of agreement) was -7.40 mmHg (-20.36 to +5.57 mmHg) for mean blood pressure, +3.54 mmHg (-20.32 to +27.41 mmHg) for systolic blood pressure, and -10.20 mmHg (-23.66 to +3.26 mmHg) for diastolic