WorldWideScience

Sample records for maximum tracer concentration

  1. Estimation of time-variable fast flow path chemical concentrations for application in tracer-based hydrograph separation analyses

    Science.gov (United States)

    Kronholm, Scott C.; Capel, Paul D.

    2016-01-01

    Mixing models are a commonly used method for hydrograph separation, but can be hindered by the subjective choice of the end-member tracer concentrations. This work tests a new variant of mixing model that uses high-frequency measures of two tracers and streamflow to separate total streamflow into water from slowflow and fastflow sources. The ratio between the concentrations of the two tracers is used to create a time-variable estimate of the concentration of each tracer in the fastflow end-member. Multiple synthetic data sets, and data from two hydrologically diverse streams, are used to test the performance and limitations of the new model (two-tracer ratio-based mixing model: TRaMM). When applied to the synthetic streams under many different scenarios, the TRaMM produces results that were reasonable approximations of the actual values of fastflow discharge (±0.1% of maximum fastflow) and fastflow tracer concentrations (±9.5% and ±16% of maximum fastflow nitrate concentration and specific conductance, respectively). With real stream data, the TRaMM produces high-frequency estimates of slowflow and fastflow discharge that align with expectations for each stream based on their respective hydrologic settings. The use of two tracers with the TRaMM provides an innovative and objective approach for estimating high-frequency fastflow concentrations and contributions of fastflow water to the stream. This provides useful information for tracking chemical movement to streams and allows for better selection and implementation of water quality management strategies.

  2. Applying tracer techniques to NPP liquid effluents for estimating the maximum concentration of soluble pollutants in a man-made canal

    International Nuclear Information System (INIS)

    Varlam, Carmen; Stefanescu, Ioan; Varlam, Mihai; Raceanu, Mircea; Enache, Adrian; Faurescu, Ionut; Patrascu, Vasile; Bucur, Cristina

    2006-01-01

    -October 2002. We established tritium level and tritium concentrations significant for the edge and the tail of tritiated wastewater evacuations. We obtained unit-peak-attenuation (UPA) curve as related to different mixing times using three locations in which we measured tracer-response curves. The UPA curve, along with the time-of travel curves, provides a ready means of predicting maximum soluble contaminant levels that could be experienced at any location in the investigated area. (authors)

  3. Simultaneous extraction and concentration of water pollution tracers using ionic-liquid-based systems.

    Science.gov (United States)

    Dinis, Teresa B V; Passos, Helena; Lima, Diana L D; Sousa, Ana C A; Coutinho, João A P; Esteves, Valdemar I; Freire, Mara G

    2017-07-29

    Human activities are responsible for the release of innumerous substances into the aquatic environment. Some of these substances can be used as pollution tracers to identify contamination sources and to prioritize monitoring and remediation actions. Thus, their identification and quantification are of high priority. However, due to their presence in complex matrices and at significantly low concentrations, a pre-treatment/concentration step is always required. As an alternative to the currently used pre-treatment methods, mainly based on solid-phase extractions, aqueous biphasic systems (ABS) composed of ionic liquids (ILs) and K 3 C 6 H 5 O 7 are here proposed for the simultaneous extraction and concentration of mixtures of two important pollution tracers, caffeine (CAF) and carbamazepine (CBZ). An initial screening of the IL chemical structure was carried out, with extraction efficiencies of both tracers to the IL-rich phase ranging between 95 and 100%, obtained in a single-step. These systems were then optimized in order to simultaneously concentrate CAF and CBZ from water samples followed by HPLC-UV analysis, for which no interferences of the ABS phase-forming components and other interferents present in a wastewater effluent sample have been found. Based on the saturation solubility data of both pollution tracers in the IL-rich phase, the maximum estimated concentration factors of CAF and CBZ are 28595- and 8259-fold. IL-based ABS can be thus envisioned as effective pre-treatment techniques of environmentally-related aqueous samples for a more accurate monitoring of mixtures of pollution tracers. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Journal: Efficient Hydrologic Tracer-Test Design for Tracer ...

    Science.gov (United States)

    Hydrological tracer testing is the most reliable diagnostic technique available for the determination of basic hydraulic and geometric parameters necessary for establishing operative solute-transport processes. Tracer-test design can be difficult because of a lack of prior knowledge of the basic hydraulic and geometric parameters desired and the appropriate tracer mass to release. A new efficient hydrologic tracer-test design (EHTD) methodology has been developed to facilitate the design of tracer tests by root determination of the one-dimensional advection-dispersion equation (ADE) using a preset average tracer concentration which provides a theoretical basis for an estimate of necessary tracer mass. The method uses basic measured field parameters (e.g., discharge, distance, cross-sectional area) that are combined in functional relatipnships that descrive solute-transport processes related to flow velocity and time of travel. These initial estimates for time of travel and velocity are then applied to a hypothetical continuous stirred tank reactor (CSTR) as an analog for the hydrological-flow system to develop initial estimates for tracer concentration, tracer mass, and axial dispersion. Application of the predicted tracer mass with the hydraulic and geometric parameters in the ADE allows for an approximation of initial sample-collection time and subsequent sample-collection frequency where a maximum of 65 samples were determined to be necessary for descri

  5. Maximum concentrations at work and maximum biologically tolerable concentration for working materials 1991

    International Nuclear Information System (INIS)

    1991-01-01

    The meaning of the term 'maximum concentration at work' in regard of various pollutants is discussed. Specifically, a number of dusts and smokes are dealt with. The valuation criteria for maximum biologically tolerable concentrations for working materials are indicated. The working materials in question are corcinogeneous substances or substances liable to cause allergies or mutate the genome. (VT) [de

  6. Concentration dynamics in lakes and reservoirs. Studies using radioactive tracers

    International Nuclear Information System (INIS)

    Gilath, Ch.

    1983-01-01

    The use of radioactive tracers for the investigation of concentration dynamics of inert soluble matter in lakes and reservoirs is reviewed. Shallow and deep stratified lakes are considered. The mechanism of mixing in lakes, flow pattern and input - output response are discussed. The methodology of the use of radioactive tracers for concentration dynamic studies is described. Examples of various investigations are reviewed. The dynamics of shallow lakes can be found and expressed in terms of transfer functions, axial dispersion models, residence time distributions and sometimes only semiquantitative information about the flow pattern. The dynamics of deep, stratified lakes is more complex and difficult to investigate with tracers. Flow pattern, horizontal and vertical eddy diffusivities, mass transfer between the hypolimnion and epilimnion are tools used for describing this dynamics. (author)

  7. Tracer concentration curves and residence time analysis in technological flow systems. 2

    International Nuclear Information System (INIS)

    Pippel, W.

    1976-01-01

    Tracer concentration curves measured in flow systems by means of radioactive isotopes are treated as a two dimensional random process. Comparing them with the family distribution functions described in part I, it follows that only in case of ergodic behaviour of the system tracer curves can be considered as age distribution functions. The conception of ergodicity in residence time systems has been explained with the aid of a time function measurable by a special method of radioactive tracer technique and by the mean value of the residence time obtainable from this function. Furthermore, technological consequences in evaluating tracer concentration curves of real flow systems are discussed with respect to supposed ergodic or nonergodic behaviour. These considerations are of special importance for flow systems with temporary fluctuations in structure. (author)

  8. Maximum Permissible Concentrations and Negligible Concentrations for pesticides

    NARCIS (Netherlands)

    Crommentuijn T; Kalf DF; Polder MD; Posthumus R; Plassche EJ van de; CSR

    1997-01-01

    Maximum Permissible Concentrations (MPCs) and Negligible Concentrations (NCs) derived for a series of pesticides are presented in this report. These MPCs and NCs are used by the Ministry of Housing, Spatial Planning and the Environment (VROM) to set Environmental Quality Objectives. For some of the

  9. Plutonium and tracer particle resuspension: an overview of selected Battelle-Northwest experiments

    International Nuclear Information System (INIS)

    Sehmel, G.A.

    1977-01-01

    Plutonium resuspension at Rocky Flats was determined in July 1973, by measuring airborne plutonium as a function of sampling height and of wind speed. The maximum airborne plutonium-239 concentration was 3700 aCi/m 3 . The maximum plutonium-239 activity per gram of collected airborne soil was 50 pCi/g. Airborne plutonium concentrations were shown to increase as the sixth power of wind speed, but the data were very imprecise. In measurement of fallout resuspension caused by burning vegetation, the 137 Cs concentration in a forest fire smoke plume was 22 times the concentration in ambient air. Resuspension rates for a man walking across a tracer area on an asphalt surface ranged from 1 x 10 -5 to 7 x 10 -4 fraction of tracer resuspended/pass. For vehicular traffic driven on a tracer lane, resuspension rates from the asphalt surface ranged from 10 -4 to 10 -2 fraction resuspended/pass. When the vehicle was driven on the lane adjacent to the tracer lane, resuspension rates were smaller, ranging from 10 -5 to 10 -3 fraction resuspended/pass. Resuspension rates decreased when the tracer had been on the ground for several days. In comparison to the asphalt surface, vehicle-caused tracer resuspension rates from a cheat grass area were lower, ranging from 10 -5 to 10 -4 fraction resuspended/pass. Wind caused tracer resuspension rates were on the order of 10 -11 fraction resuspended/sec for nonrespirable particles. Resuspension rates for respirable particles increased as the 4.8th power of wind speed, ranging from 10 -11 to 10 -7 fraction resuspended/sec. In another study, airborne respirable soil concentrations measured as a function of wind speed increased as the 0.6 to 3.2 power of wind speed

  10. A Preliminary Study on the Measurement of Sediment Concentration in Hill-Slope Runoff with an Electrolyte Tracer

    Directory of Open Access Journals (Sweden)

    Xiaonan Shi Fan Zhang

    2012-01-01

    Full Text Available Sediment concentration in hill-slope runoff is an important index for soil erosion. Developing a reliable and portable measuring system of sediment concentration is a core issue for soil and water conservation study, especially for the Tibetan Plateau under unfavorable climate and terrain conditions for field investigation. Challenges include uneven distribution of sediment across a runoff section as well as difficulty in detecting a wide range of particle sizes. An electrolyte tracer, with the advantage of uniform distribution and its widely used electric-conductivity sensor, can avoid the problems of direct measurement of sediment. A new measurement method of sediment concentration in runoff with an electrolyte tracer is proposed based on a premise that sediment concentration is closely correlated with hydrodynamic dispersion coefficient of solute in runoff. In this study, an experiment system of hill-slope runoff with an electrolyte tracer and sediments is first designed. Second, two model parameters in the advective-dispersive equation of solute transport, flow velocity and diffusion coefficient, are inversely estimated by calibrating the observed concentrations of an electrolyte tracer. And third, the relationship between sediment concentrations and hydrodynamic dispersion coefficients are defined through specified regression. As a result, a measurement system of sediment concentration in hill-slope runoff with an electrolyte tracer is primarily established by integrating the relationship of variables, experiment system, and model theory.

  11. Development of a downhole tool measuring real-time concentration of ionic tracers and pH in geothermal reservoirs

    Science.gov (United States)

    Hess, Ryan F.; Boyle, Timothy J.; Limmer, Steven; Yelton, William G.; Bingham, Samuel; Stillman, Greg; Lindblom, Scott; Cieslewski, Grzegorz

    2014-06-01

    For enhanced or Engineered Geothermal Systems (EGS) geothermal brine is pumped to the surface via the production wells, the heat extracted to turn a turbine to generate electricity, and the spent brine re-injected via injection wells back underground. If designed properly, the subsurface rock formations will lead this water back to the extraction well as heated brine. Proper monitoring of these geothermal reservoirs is essential for developing and maintaining the necessary level of productivity of the field. Chemical tracers are commonly used to characterize the fracture network and determine the connectivity between the injection and production wells. Currently, most tracer experiments involve injecting the tracer at the injection well, manually collecting liquid samples at the wellhead of the production well, and sending the samples off for laboratory analysis. While this method provides accurate tracer concentration data at very low levels of detection, it does not provide information regarding the location of the fractures which were conducting the tracer between wellbores. Sandia is developing a high-temperature electrochemical sensor capable of measuring tracer concentrations and pH downhole on a wireline tool. The goal of this effort is to collect real-time pH and ionic tracer concentration data at temperatures up to 225 °C and pressures up to 3000 psi. In this paper, a prototype electrochemical sensor and the initial data obtained will be presented detailing the measurement of iodide tracer concentrations at high temperature and pressure in a newly developed laboratory scale autoclave.

  12. Local study of pollutants dispersion by a real time tracer method

    International Nuclear Information System (INIS)

    Faivre-Pierret, R.X.; Sestier-Carlin, R.; Berne, P.

    1992-01-01

    It is possible to use a Gaussian mathematical model of atmospheric dispersion for calculating atmospheric transfer coefficient (ATC) in long range model, but for proximity models, an experimental model using a tracer technic has to take in account ground effects and natural or artificial obstacles. SF 6 tracer method gives the true plume ground trace in real time. The measured ATC shows a larger ground trace, lower concentration in the axis, and a displacement of the maximum concentration with regard to wind axis in comparison with the calculated ATC. (A.B.). 14 refs., 4 figs., 1 tab

  13. Scientific substantination of maximum allowable concentration of fluopicolide in water

    Directory of Open Access Journals (Sweden)

    Pelo I.М.

    2014-03-01

    Full Text Available In order to substantiate fluopicolide maximum allowable concentration in the water of water reservoirs the research was carried out. Methods of study: laboratory hygienic experiment using organoleptic and sanitary-chemical, sanitary-toxicological, sanitary-microbiological and mathematical methods. The results of fluopicolide influence on organoleptic properties of water, sanitary regimen of reservoirs for household purposes were given and its subthreshold concentration in water by sanitary and toxicological hazard index was calculated. The threshold concentration of the substance by the main hazard criteria was established, the maximum allowable concentration in water was substantiated. The studies led to the following conclusions: fluopicolide threshold concentration in water by organoleptic hazard index (limiting criterion – the smell – 0.15 mg/dm3, general sanitary hazard index (limiting criteria – impact on the number of saprophytic microflora, biochemical oxygen demand and nitrification – 0.015 mg/dm3, the maximum noneffective concentration – 0.14 mg/dm3, the maximum allowable concentration - 0.015 mg/dm3.

  14. Maximum phytoplankton concentrations in the sea

    DEFF Research Database (Denmark)

    Jackson, G.A.; Kiørboe, Thomas

    2008-01-01

    A simplification of plankton dynamics using coagulation theory provides predictions of the maximum algal concentration sustainable in aquatic systems. These predictions have previously been tested successfully against results from iron fertilization experiments. We extend the test to data collect...

  15. The propagation of Escherichia Coli and of conservative tracers. A comparison

    International Nuclear Information System (INIS)

    Alexander, I.; Seiler, K.P.

    1982-01-01

    The propagation of Escherichia Coli (ATCC 11229, Gelsenkirchen) is compared with that of conservative tracers in groundwater. The experiments were performed with injection quantities of 10 7 , 10 8 , 10 10 and 10 11 of Escherichia Coli. Both, bacteria and conservative tracers pass their maximum at the same instant in the observation gauges. With injection quantities of more than 10 8 , the propagation of the Escherichia Coli sets in at the same time as it begins with the dyes. When the quantities range below 10 8 , the propagation begins after that of conservative tracers, because Coli bacteria were measured with a lower degree of detecting sensitivity than the tracers. With Coli injection quantities ranging above 10 10 , an increased filtering of these bacteria can be observed. Coli bacteria propagate more laterally than conservative tracers, however it could not be proved that this lateral propagation depends on the bacteria concentration. (orig.) [de

  16. A discussion about maximum uranium concentration in digestion solution of U3O8 type uranium ore concentrate

    International Nuclear Information System (INIS)

    Xia Dechang; Liu Chao

    2012-01-01

    On the basis of discussing the influence of single factor on maximum uranium concentration in digestion solution,the influence degree of some factors such as U content, H 2 O content, mass ratio of P and U was compared and analyzed. The results indicate that the relationship between U content and maximum uranium concentration in digestion solution was direct ratio, while the U content increases by 1%, the maximum uranium concentration in digestion solution increases by 4.8%-5.7%. The relationship between H 2 O content and maximum uranium concentration in digestion solution was inverse ratio, the maximum uranium concentration in digestion solution decreases by 46.1-55.2 g/L while H 2 O content increases by 1%. The relationship between mass ratio of P and U and maximum uranium concentration in digestion solution was inverse ratio, the maximum uranium concentration in digestion solution decreases by 116.0-181.0 g/L while the mass ratio of P and U increase 0.1%. When U content equals 62.5% and the influence of mass ratio of P and U is no considered, the maximum uranium concentration in digestion solution equals 1 578 g/L; while mass ratio of P and U equals 0.35%, the maximum uranium concentration decreases to 716 g/L, the decreased rate is 54.6%, so the mass ratio of P and U in U 3 O 8 type uranium ore concentrate is the main controlling factor. (authors)

  17. Concentration dynamics in lakes and reservoirs, studies using radioactive tracers

    International Nuclear Information System (INIS)

    Gilath, C.

    1979-01-01

    The concentration dynamics in lakes and reservoirs through which water flows can be investigated by injecting a pulse of radioactive tracer and measuring the response at the outlet or any other point of interest inside the lake. The methodology developed for this Kind of investigation is presented. It was found that concentration dynamics in shallow reservoirs can be described by a model consisting of a time delay in series with one or two time constants. Procedures for the determination of the volumes of these regions are presented for reservoirs considered as either constant or variable parameter systems. The flow pattern in the reservoirs was investigated by measuring the response of the concentration through the lake and was analyzed in relation to the prevailing wind conditions. Wind induced currents have a dominant influence on the flow pattern. (Author) [pt

  18. Reconstruction of Atmospheric Tracer Releases with Optimal Resolution Features: Concentration Data Assimilation

    Science.gov (United States)

    Singh, Sarvesh Kumar; Turbelin, Gregory; Issartel, Jean-Pierre; Kumar, Pramod; Feiz, Amir Ali

    2015-04-01

    function which exhibits a priori information about the unknown releases apparent to the monitoring network. The properties of the weight function provide an optimal data resolution and model resolution to the retrieved source estimates. The retrieved source estimates are proved theoretically to be stable against the random measurement errors and their reliability can be interpreted in terms of the distribution of the weight functions. Further, the same framework can be extended for the identification of the point type releases by utilizing the maximum of the retrieved source estimates. The inversion technique has been evaluated with the several diffusion experiments, like, Idaho low wind diffusion experiment (1974), IIT Delhi tracer experiment (1991), European Tracer Experiment (1994), Fusion Field Trials (2007), etc. In case of point release experiments, the source parameters are mostly retrieved close to the true source parameters with least error. Primarily, the proposed technique overcomes two major difficulties incurred in the source reconstruction: (i) The initialization of the source parameters as required by the optimization based techniques. The converged solution depends on their initialization. (ii) The statistical knowledge about the measurement and background errors as required by the Bayesian inference based techniques. These are hypothetically assumed in case of no prior knowledge.

  19. Laser-Excited Luminescent Tracers for Planar Concentration Measurements in Gaseous Jets

    Science.gov (United States)

    Lozano, Antonio

    Tracers currently used in planar laser-induced fluorescence concentration measurements are not ideal for some experimental conditions, e.g., non-reacting turbulent gaseous flows at standard temperature and pressure. In this work, a number of chemicals have been evaluated, through consideration of their physical and photophysical properties, for use as luminescent concentration markers in turbulent gaseous flows. Two selected substances, biacetyl and acetone, have been studied in more detail. Acetone PLIF concentration images have been acquired in a non-reacting air jet, and the results have been compared to similar images obtained seeding with biacetyl. Acetone has proven to be a superior tracer when imaging fluorescence emission. Acetone has also been used as a fuel marker in hydrogen and methane diffusion flames. This single -laser technique enables simultaneous recording of the acetone and OH fluorescence emissions, as well as Mie scattering from ambient air dust particles. Acetone-sensitized, collisionally-induced biacetyl phosphorescence has been used to visualize molecular mixing in gaseous flows. Initial attempts to produce quantitative results with this method through simultaneous imaging of acetone fluorescence and collisionally-induced biacetyl emission, are described. Using laser-induced biacetyl phosphorescence imaging, a data set of cross-cut concentration images has been acquired in a nitrogen coflowing jet (Re = 5,000). The images have been statistically analyzed. Very simple models of the instantaneous concentration profile have been compared to the experimental data. Of all the tested models, a paraboloid has resulted to be the best approximation to the instantaneous 2-D profile. Finally, an experiment to study jet mixing in crossflow using acetone PLIF imaging has been designed. The flow facility has been constructed, and preliminary images obtained with a high quantum efficiency, thinned CCD detector have revealed the presence of jet structures

  20. Elemental concentrations and tracer uptake behavior of manganese, zinc, and selenium in brain of normal mice during development

    International Nuclear Information System (INIS)

    Tarohda, Tohru; Yabushita, Yuko; Kanayama, Yousuke; Amano, Ryohei; Enomoto, Shuichi

    2001-01-01

    Concentrations and uptake behavior of manganese (Mn), zinc (Zn), and selenium (Se) in mouse brain were studied by a multitracer technique, neutron activation analysis and autoradiography. Comparative concentrations on Mn, Zn, and Se and tracer uptake behavior of 54 Mn, 65 Zn, and 75 Se were examined in brains of 1-, 4-, 8-, 21-, and 56-day-old mice, and evaluated in terms of brain concentration (parts per million, ppm) and brain uptake rate (the radioactivity percentage of injected dose per gram of brain, %dose/g), respectively. As a result, the brain concentrations of Mn increased with growth, although those of Se and Zn did not change. On the other hand, the uptakes of the three tracers by brains of 1-day-old mice were much higher than those of older ones. Using radioactive 54 Mn as a single tracer, autoradiography was examined to determine the Mn uptake regional distribution in brains of 1-, 8-, and 21-day-old mice, and a higher regional uptake of Mn by the cerebral cortex, hippocampus, thalamus and hypothalamus in brains of young mice was observed. (author)

  1. Determination of the resident time distribution (RTD) in copper concentrate drying plants using radioactive tracers

    International Nuclear Information System (INIS)

    Diaz V, Francisco J.; Duran P, Oscar U.; Hernandez A, Fernando A.

    1996-01-01

    This paper is a study on the drying process of copper concentrate, on two fluidized bed dryers at Fundicion Caletones, Division El Teniente, Codelco-Chile. The problem was investigated by experimental determination of the resident Time Distribution (RTD) for the material to be dry and by an analysis of the influence of the grain size in the drying process. The stimulus-response technique was used in the experiments, where the stimulation was a pulse of an adequate radioactive tracer injected at the dryer's input. Under these conditions, the response obtained at the dryer's outputs, i.e., the concentration variation curve as a function of time, represents directly the RTD of the system between the injection and measuring points. The tracer used was the same material to be dried, and it was irradiated with neutrons in the nuclear reactor at La Reina Nuclear Centre, thus producing a solid gamma radiation emitter tracer of identical behaviour as the material under study. The approximate activity of each sample was equivalent to 8 mCi of Cu-64 at the time of the injection and the measurement of the tracer was made on-line using NaI(Tl) gamma radiation detectors. The results obtained showed average times less than the estimated and would indicate a fast drying using minimum volume in the dryer. The drying of the fine particles was three times faster than the coarse ones. (author)

  2. Transuranic and tracer simulant resuspension

    International Nuclear Information System (INIS)

    Sehmel, G.A.

    1977-07-01

    Plutonium resuspension results are summarized for experiments conducted at Rocky Flats, onsite on the Hanford reservation, and for winds blowing from offsite onto the Hanford reservation near the Prosser barricade boundary. In each case, plutonium resuspension was shown by increased airborne plutonium concentrations as a function of either wind speed or as compared to fallout levels. All measured airborne concentrations were below maximum permissible concentrations (MPC). Both plutonium and cesium concentrations on airborne soil were normalized by the quantity of airborne soil sampled. Airborne radionuclide concentrations in μCi/g were related to published values for radionuclide concentrations on surface soils. For this ratio of radionuclide concentration per gram on airborne soil divided by that for ground surface soil, there are eight orders of magnitude uncertainty from 10 -4 to 10 4 . Horizontal plutonium fluxes on airborne nonrespirable soils at all three sites were bracketed within the same three to four orders of magnitude from 10 -7 to 10 -3 μCi/(m 2 day) for plutonium-239 and 10 -8 to 10 -5 μCi/(m 2 day) for plutonium-238. These are the entire experimental base for nonrespirable airborne plutonium transport. Airborne respirable plutonium-239 concentrations increased with wind speed for a southeast wind direction coming from offsite near the Hanford reservation Prosser barricade. Airborne plutonium fluxes on nonrespirable particles had isotopic ratios, 240 Pu/ 239+240 Pu, similar to weapons grade plutonium rather than fallout plutonium. Resuspension rates were summarized for controlled inert particle tracer simulant experiments. Wind resuspension rates for tracers increased with wind speed to about the fifth power

  3. Crustal tracers in the atmosphere and ocean: Relating their concentrations, fluxes, and ages

    Science.gov (United States)

    Han, Qin

    Crustal tracers are important sources of key limiting nutrients (e.g., iron) in remote ocean regions where they have a large impact on global biogeochemical cycles. However, the atmospheric delivery of bio-available iron to oceans via mineral dust aerosol deposition is poorly constrained. This dissertation aims to improve understanding and model representation of oceanic dust deposition and to provide soluble iron flux maps by testing observations of crustal tracer concentrations and solubilities against predictions from two conceptual solubility models. First, we assemble a database of ocean surface dissolved Al and incorporate Al cycling into the global Biogeochemical Elemental Cycling (BEC) model. The observed Al concentrations show clear basin-scale differences that are useful for constraining dust deposition. The dynamic mixed layer depth and Al residence time in the BEC model significantly improve the simulated dissolved Al field. Some of the remaining model-data discrepancies appear related to the neglect of aerosol size, age, and air mass characteristics in estimating tracer solubility. Next, we develop the Mass-Age Tracking method (MAT) to efficiently and accurately estimate the mass-weighted age of tracers. We apply MAT to four sizes of desert dust aerosol and simulate, for the first time, global distributions of aerosol age in the atmosphere and at deposition. These dust size and age distributions at deposition, together with independent information on air mass acidity, allow us to test two simple yet plausible models for predicting the dissolution of mineral dust iron and aluminum during atmospheric transport. These models represent aerosol solubility as controlled (1) by a diffusive process leaching nutrients from the dust into equilibrium with the liquid water coating or (2) by a process that continually dissolves nutrients in proportion to the particle surface area. The surface-controlled model better captures the spatial pattern of observed

  4. Coefficients of tracer transfer through membranes. Pt. 7

    Energy Technology Data Exchange (ETDEWEB)

    Dorabialska, A; Hawlicka, E; Plonka, A [Politechnika Lodzka (Poland)

    1974-01-01

    The doubled value of the tracer transfer coefficient in the self-diffusion process is equal to the sum of tracer transfer coefficients in the diffusion and interfusion processes. The fundamental phenomenological relation can be deduced for the coefficients of tracer transfer between two phases of electrolyte solutions spearated by a virtual boundary. Indeed, the doubled value of the tracer mobility in the self-diffusion experiment (no concentration gradient of the traced substance) is equal to the sum of the tracer mobilities in the diffusion (tracer movement along with the concentration gradient of the traced substance) and interfusion experiments (tracer movement against the concentration gradient of the traced substance). Thus the doubled value of the tracer transfer coefficient in the self-diffusion process should be equal to the sum of tracer transfer coefficients in the diffusion and interfusion processes. The experimental verification of that fundamental relation is presented.

  5. Estimation of maximum credible atmospheric radioactivity concentrations and dose rates from nuclear tests

    International Nuclear Information System (INIS)

    Telegadas, K.

    1979-01-01

    A simple technique is presented for estimating maximum credible gross beta air concentrations from nuclear detonations in the atmosphere, based on aircraft sampling of radioactivity following each Chinese nuclear test from 1964 to 1976. The calculated concentration is a function of the total yield and fission yield, initial vertical radioactivity distribution, time after detonation, and rate of horizontal spread of the debris with time. calculated maximum credible concentrations are compared with the highest concentrations measured during aircraft sampling. The technique provides a reasonable estimate of maximum air concentrations from 1 to 10 days after a detonation. An estimate of the whole-body external gamma dose rate corresponding to the maximum credible gross beta concentration is also given. (author)

  6. Predicted fate of tritium residuum from groundwater tracer experiments in the Amargosa Desert, southern Nevada

    International Nuclear Information System (INIS)

    Brikowski, T.

    1993-07-01

    Analytic solutions are used in this study to evaluate potential groundwater transport of tritium used in goundwater tracer tests southwest of the Nevada Test Site. Possible transport from this site is of interest because initial radionuclide concentrations were high and the site is close to goundwater discharge points (12 km). Anecdotal evidence indicates that 90 percent of these tracers were removed by pumping at the completion of the tests; this study examines the probable transport of the tracers with and without the removal. Classical dispersive transport analytic solutions are used, treating the tracer test as a point slug injection. Input parameters for the solutions were measured at the site, and consideration of parameter uncertainty is incorporated in the results. With removal of the tracer, the maximum expected region with above-Safe Drinking Water Act (40 CFR 121) concentrations of tritium extends 5 km from the injection point, and does not reach any sites of public access. Detectable tritium from the tests is likely to have reached the Ash Meadows fault zone, but flow along the fault probably diluted the tracer to below detection limits before arrival at springs along the fault. Arrival at the springs would have occurred 20 to 25 years after the tests. Without removal of the tracer, the solutions indicate that tritium concentrations just above Safe Drinking Water Act standards would have reached the Ash Meadows fault zone. In this case, detectable tritium might have been found in Devil's Hole or Longstreet Spring, the nearest points of possible public exposure

  7. Evaluation of Parameter Uncertainty Reduction in Groundwater Flow Modeling Using Multiple Environmental Tracers

    Science.gov (United States)

    Arnold, B. W.; Gardner, P.

    2013-12-01

    Calibration of groundwater flow models for the purpose of evaluating flow and aquifer heterogeneity typically uses observations of hydraulic head in wells and appropriate boundary conditions. Environmental tracers have a wide variety of decay rates and input signals in recharge, resulting in a potentially broad source of additional information to constrain flow rates and heterogeneity. A numerical study was conducted to evaluate the reduction in uncertainty during model calibration using observations of various environmental tracers and combinations of tracers. A synthetic data set was constructed by simulating steady groundwater flow and transient tracer transport in a high-resolution, 2-D aquifer with heterogeneous permeability and porosity using the PFLOTRAN software code. Data on pressure and tracer concentration were extracted at well locations and then used as observations for automated calibration of a flow and transport model using the pilot point method and the PEST code. Optimization runs were performed to estimate parameter values of permeability at 30 pilot points in the model domain for cases using 42 observations of: 1) pressure, 2) pressure and CFC11 concentrations, 3) pressure and Ar-39 concentrations, and 4) pressure, CFC11, Ar-39, tritium, and He-3 concentrations. Results show significantly lower uncertainty, as indicated by the 95% linear confidence intervals, in permeability values at the pilot points for cases including observations of environmental tracer concentrations. The average linear uncertainty range for permeability at the pilot points using pressure observations alone is 4.6 orders of magnitude, using pressure and CFC11 concentrations is 1.6 orders of magnitude, using pressure and Ar-39 concentrations is 0.9 order of magnitude, and using pressure, CFC11, Ar-39, tritium, and He-3 concentrations is 1.0 order of magnitude. Data on Ar-39 concentrations result in the greatest parameter uncertainty reduction because its half-life of 269

  8. Fluorescent bioaerosol particle, molecular tracer, and fungal spore concentrations during dry and rainy periods in a semi-arid forest

    Directory of Open Access Journals (Sweden)

    M. I. Gosselin

    2016-12-01

    Full Text Available Bioaerosols pose risks to human health and agriculture and may influence the evolution of mixed-phase clouds and the hydrological cycle on local and regional scales. The availability and reliability of methods and data on the abundance and properties of atmospheric bioaerosols, however, are rather limited. Here we analyze and compare data from different real-time ultraviolet laser/light-induced fluorescence (UV-LIF instruments with results from a culture-based spore sampler and offline molecular tracers for airborne fungal spores in a semi-arid forest in the southern Rocky Mountains of Colorado. Commercial UV-APS (ultraviolet aerodynamic particle sizer and WIBS-3 (wideband integrated bioaerosol sensor, version 3 instruments with different excitation and emission wavelengths were utilized to measure fluorescent aerosol particles (FAPs during both dry weather conditions and periods heavily influenced by rain. Seven molecular tracers of bioaerosols were quantified by analysis of total suspended particle (TSP high-volume filter samples using a high-performance anion-exchange chromatography system with pulsed amperometric detection (HPAEC-PAD. From the same measurement campaign, Huffman et al. (2013 previously reported dramatic increases in total and fluorescent particle concentrations during and immediately after rainfall and also showed a strong relationship between the concentrations of FAPs and ice nuclei (Huffman et al., 2013; Prenni et al., 2013. Here we investigate molecular tracers and show that during rainy periods the atmospheric concentrations of arabitol (35.2 ± 10.5 ng m−3 and mannitol (44.9 ± 13.8 ng m−3 were 3–4 times higher than during dry periods. During and after rain, the correlations between FAP and tracer mass concentrations were also significantly improved. Fungal spore number concentrations on the order of 104 m−3, accounting for 2–5 % of TSP mass during dry periods and 17–23 % during rainy

  9. Improved sentinel node visualization in breast cancer by optimizing the colloid particle concentration and tracer dosage

    NARCIS (Netherlands)

    Valdés Olmos, R. A.; Tanis, P. J.; Hoefnagel, C. A.; Nieweg, O. E.; Muller, S. H.; Rutgers, E. J.; Kooi, M. L.; Kroon, B. B.

    2001-01-01

    Faint lymph uptake may hamper sentinel node (SN) identification by scintigraphy and subsequent gamma probe localization. The aim of the present study was to evaluate an adjustment in the colloid particle concentration and tracer dosage to optimize mammary lymphoscintigraphy. Scintigraphy was

  10. CityFlux perfluorocarbon tracer experiments

    Science.gov (United States)

    Petersson, F. K.; Martin, D.; White, I. R.; Henshaw, S. J.; Nickless, G.; Longley, I.; Percival, C. J.; Gallagher, M.; Shallcross, D. E.

    2010-07-01

    In June 2006, two perfluorocarbon tracer experiments were conducted in central Manchester UK as part of the CityFlux campaign. The main aim was to investigate vertical dispersion in an urban area during convective conditions, but dispersion mechanisms within the street network were also studied. Paired receptors were used in most cases where one receptor was located at ground level and one at roof level. One receptor was located on the roof of Portland Tower which is an 80 m high building in central Manchester. Source receptor distances in the two experiments varied between 120 and 600 m. The results reveal that maximum concentration was sometimes found at roof level rather than at ground level implying the effectiveness of convective forces on dispersion. The degree of vertical dispersion was found to be dependent on source receptor distance as well as on building height in proximity to the release site. Evidence of flow channelling in a street canyon was also found. Both a Gaussian profile and a street network model were applied and the results show that the urban topography may lead to highly effective flow channelling which therefore may be a very important dispersion mechanism should the right meteorological conditions prevail. The experimental results from this campaign have also been compared with a simple urban dispersion model that was developed during the DAPPLE framework and show good agreement with this. The results presented here are some of the first published regarding vertical dispersion. More tracer experiments are needed in order to further characterise vertical concentration profiles and their dependence on, for instance, atmospheric stability. The impact of urban topography on pollutant dispersion is important to focus on in future tracer experiments in order to improve performance of models as well as for our understanding of the relationship between air quality and public health.

  11. Maximum permissible concentrations and negligible concentrations for antifouling substances. Irgarol 1051, dichlofluanid, ziram, chlorothalonil and TCMTB

    NARCIS (Netherlands)

    Wezel AP van; Vlaardingen P van; CSR

    2001-01-01

    This report presents maximum permissible concentrations and negligible concentrations that have been derived for various antifouling substances used as substitutes for TBT. Included here are Irgarol 1051, dichlofluanide, ziram, chlorothalonil and TCMTB.

  12. The European Tracer Experiment - experimental results and database

    International Nuclear Information System (INIS)

    Nodop, K.; Connolly, R.; Girardi, F.

    1997-01-01

    As part of the European Tracer Experiment (ETEX) two successful atmospheric experiments were carried out in October and November, 1994. Perfluorocarbon (PFC) tracers were released into the atmosphere in Monterfil, Brittany, and air samples were taken at 168 stations in 17 European countries for 72 hours after the release. Upper air tracer measurements were made from three aircraft. During the first experiment a westerly air flow transported the tracer plume north-eastwards across Europe. During the second release the flow was eastwards. The results from the ground sampling network allowed the determination of the cloud evolution as far as Sweden, Poland and Bulgaria. Typical background concentrations of the tracer used are around 5 to 7 fl/l in ambient air. Concentrations in the plume ranged from 10 to above 200 fl/l. The tracer release characteristics, the tracer concentrations at the ground and in upper air, the routine and additional meteorological observations at the ground level and in upper air, trajectories derived from constant-level balloons and the meteorological input fields for long-range transport (LRT) models are assembled in the ETEX database. The ETEX database is accessible via the Internet

  13. Tracers of air-sea gas exchange

    International Nuclear Information System (INIS)

    Liss, P.S.

    1988-01-01

    The flux of gas across the air-sea interface is determined by the product of the interfacial concentration difference driving the exchange and a rate constant, often termed the transfer velocity. The concentration-difference term is generally obtained by direct measurement, whereas more indirect approaches are required to estimate the transfer velocity and its variation as a function of controlling parameters such as wind and sea state. Radioactive tracers have proved particularly useful in the estimation of air-sea transfer velocities and, recently, stable purposeful tracers have also started to be used. In this paper the use of the following tracers to determine transfer velocities at the sea surface is discussed: natural and bomb-produced 14 C, dissolved oxygen, 222 Rn and sulphur hexafluoride. Other topics covered include the relation between transfer velocity and wind speed as deduced from tracer and wind-tunnel studies, and the discrepancy between transfer velocities determined by using tracers and from eddy correlation measurements in the atmosphere. (author)

  14. Chemotherapeutic agent and tracer composition and use thereof

    International Nuclear Information System (INIS)

    Babb, A. L.

    1985-01-01

    A therapeutic composition suitable for extracorporeal treatment of whole blood comprises a dialyzable chemotherapeutic agent and a dialyzable fluorescable tracer means. The removal rate of the fluorescable tracer compound from treated blood during hemodialysis is a function of the removal rate of unreacted chemotherapeutic agent present. The residual chemotherapeutic agent concentration after hemodialysis is ascertained by measuring the concentration of the fluorescable tracer compound in a dialysate using fluorometric techniques

  15. Pharmaceuticals as Groundwater Tracers - Applications and Limitations

    Science.gov (United States)

    Scheytt, T. J.; Mersmann, P.; Heberer, T.

    2003-12-01

    Pharmaceutically active substances and metabolites are found at concentrations up to the microgram/L-level in groundwater samples from the Berlin (Germany) area and from several other places world wide. Among the compounds detected in groundwater are clofibric acid, propyphenazone, diclofenac, ibuprofen, and carbamazepine. Clofibric acid, the active metabolite of clofibrate and etofibrate (blood lipid regulators) is detected in groundwater at maximum concentrations of 7300 ng/L. Among the most important input paths of drugs are excretion and disposal into the sewage system. Groundwater contamination is likely to be due to leaky sewage systems, influent streams, bank filtration, and irrigation with effluent water from sewage treatment plants. There are no known natural sources of the above mentioned pharmaceuticals. The use of pharmaceuticals as tracers may include: (a) Quantification of infiltration from underground septic tanks (b) Detection of leaky sewage systems / leaky sewage pipes (c) Estimation of the effectiveness of sewage treatment plants (d) Identification of transport pathways of other organic compounds (e) Quantification of surface water / groundwater interaction (f) Characterization of the biodegradation potential. The use of pharmaceuticals as tracers is limited by variations in input. These variations depend on the amount of drugs prescribed and used in the study area, the social structure of the community, the amount of hospital discharge, and temporal concentration variations. Furthermore, the analysis of trace amounts of pharmaceuticals is sophisticated and expensive and may therefore limit the applicability of pharmaceuticals as tracers. Finally, the transport and degradation behavior of pharmaceuticals is not fully understood. Preliminary experiments in the laboratory were conducted using sediment material and groundwater from the Berlin area to evaluate the transport and sorption behavior of selected drugs. Results of the column experiments

  16. Gas transport below artificial recharge ponds: insights from dissolved noble gases and a dual gas (SF6 and 3He) tracer experiment.

    Science.gov (United States)

    Clark, Jordan F; Hudson, G Bryant; Avisar, Dror

    2005-06-01

    A dual gas tracer experiment using sulfur hexafluoride (SF6) and an isotope of helium (3He) and measurements of dissolved noble gases was performed at the El Rio spreading grounds to examine gas transport and trapped air below an artificial recharge pond with a very high recharge rate (approximately 4 m day(-1)). Noble gas concentrations in the groundwater were greater than in surface water due to excess air formation showing that trapped air exists below the pond. Breakthrough curves of SF6 and 3He at two nearby production wells were very similar and suggest that nonequilibrium gas transfer was occurring between the percolating water and the trapped air. At one well screened between 50 and 90 m below ground, both tracers were detected after 5 days and reached a maximum at approximately 24 days. Despite the potential dilution caused by mixing within the production well, the maximum concentration was approximately 25% of the mean pond concentration. More than 50% of the SF6 recharged was recovered by the production wells during the 18 month long experiment. Our results demonstrate that at artificial recharge sites with high infiltration rates and moderately deep water tables, transport times between recharge locations and wells determined with gas tracer experiments are reliable.

  17. Tracer techniques in microelectronics

    International Nuclear Information System (INIS)

    Flachowsky, J.; Freyer, K.

    1981-01-01

    Tracer technique and neutron activation analysis are capable of measuring impurities in semiconductor material or on the semiconductor surface in a very low concentration range. The methods, combined with autoradiography, are also suitable to determine dopant distributions in silicon. However, both techniques suffer from certain inherent experimental difficulties and/or limitations which are discussed. Methods of tracer technique practicable in the semiconductor field are described. (author)

  18. Numerical Simulation of a Tracer Experiment at the Wolsong Nuclear Site

    International Nuclear Information System (INIS)

    Jeong, Hyojoon; Kim, Eunhan; Park, Misun; Jeong, Haesun; Hwang, Wontae; Han, Moonhee

    2014-01-01

    By comparing the concentration of a tracer measured under weather conditions that are disadvantageous to the dilution of radioactive materials released from the Wolsong Nuclear Power Plant, with the concentration of a tracer calculated using an air Dispersion model, it is possible to evaluate the characteristics of the air concentrations of radioactive materials estimated with an air Dispersion model, which can then be used in an environmental impact analysis of radioactive materials. Therefore, a field Dispersion experiment has been carried out to figure out the behavioral characteristics of the tracer under weather conditions that are disadvantageous to the dilution of radioactive materials released from the Wolsong Nuclear Power Plant site in Korea. In addition, through a comparison of the tracer concentrations estimated by the Gaussian plume model with measurements, this study checked the degree of conservative estimation for the Gaussian plume at the Wolsong nuclear site in Korea. A tracer Dispersion experiment using an SF 6 trace was implemented to determine the Dispersion characteristics of radioactive materials at the Wolsong Nuclear Power Plant site in Korea. Based on meteorological data and the emission rate of the tracers, this study estimated the tracer concentrations using a Gaussian plume model, and then compared it with the measurement to check the conservative estimation of the Gaussian plume model. The measured concentrations of the tracer tends to be lower than the concentrations estimated by the Gaussian plume model overall

  19. CityFlux perfluorocarbon tracer experiments

    Directory of Open Access Journals (Sweden)

    F. K. Petersson

    2010-07-01

    Full Text Available In June 2006, two perfluorocarbon tracer experiments were conducted in central Manchester UK as part of the CityFlux campaign. The main aim was to investigate vertical dispersion in an urban area during convective conditions, but dispersion mechanisms within the street network were also studied. Paired receptors were used in most cases where one receptor was located at ground level and one at roof level. One receptor was located on the roof of Portland Tower which is an 80 m high building in central Manchester. Source receptor distances in the two experiments varied between 120 and 600 m.

    The results reveal that maximum concentration was sometimes found at roof level rather than at ground level implying the effectiveness of convective forces on dispersion. The degree of vertical dispersion was found to be dependent on source receptor distance as well as on building height in proximity to the release site.

    Evidence of flow channelling in a street canyon was also found. Both a Gaussian profile and a street network model were applied and the results show that the urban topography may lead to highly effective flow channelling which therefore may be a very important dispersion mechanism should the right meteorological conditions prevail.

    The experimental results from this campaign have also been compared with a simple urban dispersion model that was developed during the DAPPLE framework and show good agreement with this.

    The results presented here are some of the first published regarding vertical dispersion. More tracer experiments are needed in order to further characterise vertical concentration profiles and their dependence on, for instance, atmospheric stability. The impact of urban topography on pollutant dispersion is important to focus on in future tracer experiments in order to improve performance of models as well as for our understanding of the relationship between air quality and public health.

  20. 237 Np analytical method using 239 Np tracers and application to a contaminated nuclear disposal facility

    Energy Technology Data Exchange (ETDEWEB)

    Snow, Mathew S.; Morrison, Samuel S.; Clark, Sue B.; Olson, John E.; Watrous, Matthew G.

    2017-06-01

    Environmental 237Np analyses are challenged by low 237Np concentrations and lack of an available yield tracer; we report a rapid, inexpensive 237Np analytical approach employing the short lived 239Np (t1/2 = 2.3 days) as a chemical yield tracer followed by 237Np quantification using inductively coupled plasma-mass spectrometry. 239Np tracer is obtained via separation from a 243Am stock solution and standardized using gamma spectrometry immediately prior to sample processing. Rapid digestions using a commercial, 900 watt “Walmart” microwave and Parr microwave vessels result in 99.8 ± 0.1% digestion yields, while chromatographic separations enable Np/U separation factors on the order of 106 and total Np yields of 95 ± 4% (2σ). Application of this method to legacy soil samples surrounding a radioactive disposal facility (the Subsurface Disposal Area at Idaho National Laboratory) reveal the presence of low level 237Np contamination within 600 meters of this site, with maximum 237Np concentrations on the order of 103 times greater than nuclear weapons testing fallout levels.

  1. Meteorological tracers in regional planning

    International Nuclear Information System (INIS)

    Mueller, K.H.

    1974-11-01

    Atmospheric tracers can be used as indicators to study both the ventilation of an urban region and its dispersion meteorology for air pollutants. A correlation analysis applied to the space-time dependent tracer concentrations is able to give transfer functions, the structure and characteristic parameters of which describe the meteorological and topographical situation of the urban region and its surroundings in an integral manner. To reduce the number of persons usually involved in a tracer experiment an automatic air sampling system had to be developed

  2. Emission quantification using the tracer gas dispersion method: The influence of instrument, tracer gas species and source simulation

    DEFF Research Database (Denmark)

    Delre, Antonio; Mønster, Jacob; Samuelsson, Jerker

    2018-01-01

    The tracer gas dispersion method (TDM) is a remote sensing method used for quantifying fugitive emissions by relying on the controlled release of a tracer gas at the source, combined with concentration measurements of the tracer and target gas plumes. The TDM was tested at a wastewater treatment...... plant for plant-integrated methane emission quantification, using four analytical instruments simultaneously and four different tracer gases. Measurements performed using a combination of an analytical instrument and a tracer gas, with a high ratio between the tracer gas release rate and instrument...... precision (a high release-precision ratio), resulted in well-defined plumes with a high signal-to-noise ratio and a high methane-to-tracer gas correlation factor. Measured methane emission rates differed by up to 18% from the mean value when measurements were performed using seven different instrument...

  3. Tracer simulation using a global general circulation model: Results from a midlatitude instantaneous source experiment

    International Nuclear Information System (INIS)

    Mahlman, J.D.; Moxim, W.J.

    1978-01-01

    An 11-level general circulation model with seasonal variation is used to perform an experiment on the dispersion of passive tracers. Specially constructed time-dependent winds from this model are used as input to a separate tracer model. The methodologies employed to construct the tracer model are described.The experiment presented is the evolution of a hypothetical instantaneous source of tracer on 1 Janaury with maximum initial concentration at 65 mb, 36 0 N, 180 0 E. The tracer is assumed to have no sources or sinks in the stratosphere, but is subject to removal processes in the lower troposphere.The experimental results reveal a number of similarities to observed tracer behavior, including the average poleward-downward slope of mixing ratio isopleths, strong tracer gradients across the tropopause, intrusion of tracer into the Southern Hemisphere lower stratosphere, and the long-term interhemispheric exchange rate. The model residence times show behavior intermediate to those exhibited for particulate radioactive debris and gaseous C 14 O 2 . This suggests that caution should be employed when either radioactive debris or C 14 O 2 data are used to develop empirical models for prediction of gaseous tracers which are efficiently removed in the troposphere.In this experiment, the tracer mixing ratio and potential vorticity evolve to very high correlations. Mechanisms for this correlation are discussed. The zonal mean tracer balances exhibit complex behavior among the various transport terms. At early stages, the tracer evolution is dominated by eddy effects. Later, a very large degree of self-cancellation between mean cell and eddy effects is observed. During seasonal transitions, however, this self-cancellation diminishes markedly, leading to significant changes in the zonal mean tracer distribution. A possible theoretical explanation is presented

  4. Nanoparticle tracers in calcium carbonate porous media

    KAUST Repository

    Li, Yan Vivian; Cathles, Lawrence M.; Archer, Lynden A.

    2014-01-01

    the fractures or channels where flow occurs and thus take much less time to travel between two points. In combination with a chemical tracer they can measure the degree of flow concentration. A prerequisite for tracer applications is that the particles

  5. Doublet Tracer Testing in Klamath Falls, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, J S; Johnson, S E; Horne, R N; Jackson, P B [Pet. Eng. Dept., Stanford University; Culver, G G [Geo-Heat Center, Oregon Institute of Technology, Klamath Falls, OR

    0000-12-30

    A tracer test was carried out in a geothermal doublet system to study the injection behavior of a developed reservoir known to be fractured. The doublet produces about 320 gpm of 160 degrees Fahrenheit water that is used for space heating and then injected; the wells are spaced 250 ft apart. Tracer breakthrough was observed in 2 hours and 45 minutes in the production well, indicating fracture flow. However, the tracer concentrations were low and indicated porous media flow; the tracers mixed with a reservoir volume much larger than a fracture.

  6. Doublet Tracer Testing in Klamath Falls, Oregon

    Energy Technology Data Exchange (ETDEWEB)

    Gudmundsson, J.S.; Johnson, S.E.; Horne, R.N.; Jackson, P. B. [Pet. Eng. Dept., Stanford University; Culver, G.G. [Geo-Heat Center, Oregon Institute of Technology, Klamath Falls, OR

    0001-01-01

    A tracer test was carried out in a geothermal doublet system to study the injection behavior of a developed reservoir known to be fractured. The doublet produces about 320 gpm of 160 degrees Fahrenheit water that is used for space heating and then injected; the wells are spaced 250 ft apart. Tracer breakthrough was observed in 2 hours and 45 minutes in the production well, indicating fracture flow. However, the tracer concentrations were low and indicated porous media flow; the tracers mixed with a reservoir volume much larger than a fracture.

  7. Laser system for measuring small changes in plasma tracer concentrations.

    Science.gov (United States)

    Klaesner, J W; Pou, N A; Parker, R E; Galloway, R L; Roselli, R J

    1996-01-01

    The authors developed a laser-diode system that can be used for on-line optical concentration measurements in physiologic systems. Previous optical systems applied to whole blood have been hampered by artifacts introduced by red blood cells (RBCs). The system introduced here uses a commercially available filter cartridge to separate RBCs from plasma before plasma concentration measurements are made at a single wavelength. The filtering characteristics of the Cellco filter cartridge (#4007-10, German-town, MD) were adequate for use in the on-line measurement system. The response time of the filter cartridge was less than 40 seconds, and the sieving characteristics of the filter for macromolecules were excellent, with filtrate-to-plasma albumin ratios of 0.98 +/- 0.11 for studies in sheep and 0.94 +/- 0.15 for studies in dogs. The 635-nm laser diode system developed was shown to be more sensitive than the spectrophotometer used in previous studies (Klaesner et al., Annals of Biomedical Engineering, 1994; 22, 660-73). The new system was used to measure the product of filtration coefficient (Kfc) and reflection coefficient for albumin (delta f) in an isolated canine lung preparation. The delta fKfc values [mL/(cmH2O.min.100 g dry lung weight)] measured with the laser diode system (0.33 +/- 0.22) compared favorably with the delta fKfc obtained using a spectrophotometer (0.27 +/- 0.20) and with the Kfc obtained using the blood-corrected gravimetric method (0.32 +/- 0.23). Thus, this new optical system was shown to accurately measure plasma concentration changes in whole blood for physiologic levels of Kfc. The same system can be used with different optical tracers and different source wavelengths to make optical plasma concentration measurements for other physiologic applications.

  8. Field measurements of tracer gas transport by barometric pumping

    International Nuclear Information System (INIS)

    Lagus, P.L.; McKinnis, W.B.; Hearst, J.R.; Burkhard, N.R.; Smith, C.F.

    1994-01-01

    Vertical gas motions induced by barometric pressure variations can carry radioactive gases out of the rubblized region produced by an underground nuclear explosion, through overburden rock, into the atmosphere. To better quantify transit time and amount of transport, field experiments were conducted at two sites on Pahute Mesa, Kapelli and Tierra, where radioactive gases had been earlier detected in surface cracks. At each site, two tracer gases were injected into the rubblized chimney 300-400 m beneath the surface and their arrival was monitored by concentration measurements in gas samples extracted from shallow collection holes. The first ''active'' tracer was driven by a large quantity of injected air; the second ''passive'' tracer was introduced with minimal gas drive to observe the natural transport by barometric pumping. Kapelli was injected in the fall of 1990, followed by Tierra in the fall of 1991. Data was collected at both sites through the summer of 1993. At both sites, no surface arrival of tracer was observed during the active phase of the experiment despite the injection of several million cubic feet of air, suggesting that cavity pressurization is likely to induce horizontal transport along high permeability layers rather than vertical transport to the surface. In contrast, the vertical pressure gradients associated with barometric pumping brought both tracers to the surface in comparable concentrations within three months at Kapelli, whereas 15 months elapsed before surface arrival at Tierra. At Kapelli, a quasisteady pumping regime was established, with tracer concentrations in effluent gases 1000 times smaller than concentrations thought to exist in the chimney. Tracer concentrations observed at Tierra were typically an order of magnitude smaller. Comparisons with theoretical calculations suggest that the gases are traveling through ∼1 millimeter vertical fractures spaced 2 to 4 meters apart. 6 refs., 18 figs., 3 tabs

  9. 237Np analytical method using 239Np tracers and application to a contaminated nuclear disposal facility.

    Science.gov (United States)

    Snow, Mathew S; Morrison, Samuel S; Clark, Sue B; Olson, John E; Watrous, Matthew G

    2017-06-01

    Environmental 237 Np analyses are challenged by low 237 Np concentrations and lack of an available yield tracer; we report a rapid, inexpensive 237 Np analytical approach employing the short lived 239 Np (t 1/2  = 2.3 days) as a chemical yield tracer followed by 237 Np quantification using inductively coupled plasma-mass spectrometry. 239 Np tracer is obtained via separation from a 243 Am stock solution and standardized using gamma spectrometry immediately prior to sample processing. Rapid digestions using a commercial, 900 W "Walmart" microwave and Parr microwave vessels result in 99.8 ± 0.1% digestion yields, while chromatographic separations enable Np/U separation factors on the order of 10 6 and total Np yields of 95 ± 4% (2σ). Application of this method to legacy soil samples surrounding a radioactive disposal facility (the Subsurface Disposal Area at Idaho National Laboratory) reveal the presence of low level 237 Np contamination within 600 m of this site, with maximum 237 Np concentrations on the order of 10 3 times greater than nuclear weapons testing fallout levels. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Double-tailored nonimaging reflector optics for maximum-performance solar concentration.

    Science.gov (United States)

    Goldstein, Alex; Gordon, Jeffrey M

    2010-09-01

    A nonimaging strategy that tailors two mirror contours for concentration near the étendue limit is explored, prompted by solar applications where a sizable gap between the optic and absorber is required. Subtle limitations of this simultaneous multiple surface method approach are derived, rooted in the manner in which phase space boundaries can be tailored according to the edge-ray principle. The fundamental categories of double-tailored reflective optics are identified, only a minority of which can pragmatically offer maximum concentration at high collection efficiency. Illustrative examples confirm that acceptance half-angles as large as 30 mrad can be realized at a flux concentration of approximately 1000.

  11. Radiation dose estimates for carbon-11-labelled PET tracers

    International Nuclear Information System (INIS)

    Aart, Jasper van der; Hallett, William A.; Rabiner, Eugenii A.; Passchier, Jan; Comley, Robert A.

    2012-01-01

    Introduction: Carbon-11-labelled positron emission tomography (PET) tracers commonly used in biomedical research expose subjects to ionising radiation. Dosimetry is the measurement of radiation dose, but also commonly refers to the estimation of health risk associated with ionising radiation. This review describes radiation dosimetry of carbon-11-labelled molecules in the context of current PET research and the most widely used regulatory guidelines. Methods: A MEDLINE literature search returned 42 articles; 32 of these were based on human PET data dealing with radiation dosimetry of carbon-11 molecules. Radiation burden expressed as effective dose and maximum absorbed organ dose was compared between tracers. Results: All but one of the carbon-11-labelled PET tracers have an effective dose under 9 μSv/MBq, with a mean of 5.9 μSv/MBq. Data show that serial PET scans in a single subject are feasible for the majority of radiotracers. Conclusion: Although differing in approach, the two most widely used regulatory frameworks (those in the USA and the EU) do not differ substantially with regard to the maximum allowable injected activity per PET study. The predictive validity of animal dosimetry models is critically discussed in relation to human dosimetry. Finally, empirical PET data are related to human dose estimates based on homogenous distribution, generic models and maximum cumulated activities. Despite the contribution of these models to general risk estimation, human dosimetry studies are recommended where continued use of a new PET tracer is foreseen.

  12. Quantifying stream nutrient uptake from ambient to saturation with instantaneous tracer additions

    Science.gov (United States)

    Covino, T. P.; McGlynn, B. L.; McNamara, R.

    2009-12-01

    Stream nutrient tracer additions and spiraling metrics are frequently used to quantify stream ecosystem behavior. However, standard approaches limit our understanding of aquatic biogeochemistry. Specifically, the relationship between in-stream nutrient concentration and stream nutrient spiraling has not been characterized. The standard constant rate (steady-state) approach to stream spiraling parameter estimation, either through elevating nutrient concentration or adding isotopically labeled tracers (e.g. 15N), provides little information regarding the stream kinetic curve that represents the uptake-concentration relationship analogous to the Michaelis-Menten curve. These standard approaches provide single or a few data points and often focus on estimating ambient uptake under the conditions at the time of the experiment. Here we outline and demonstrate a new method using instantaneous nutrient additions and dynamic analyses of breakthrough curve (BTC) data to characterize the full relationship between spiraling metrics and nutrient concentration. We compare the results from these dynamic analyses to BTC-integrated, and standard steady-state approaches. Our results indicate good agreement between these three approaches but we highlight the advantages of our dynamic method. Specifically, our new dynamic method provides a cost-effective and efficient approach to: 1) characterize full concentration-spiraling metric curves; 2) estimate ambient spiraling metrics; 3) estimate Michaelis-Menten parameters maximum uptake (Umax) and the half-saturation constant (Km) from developed uptake-concentration kinetic curves, and; 4) measure dynamic nutrient spiraling in larger rivers where steady-state approaches are impractical.

  13. Diagnostic Implications of the Reactivity of Fluorescence Tracers

    Energy Technology Data Exchange (ETDEWEB)

    Sick, V; Westbrook, C

    2008-07-14

    Measurements of fuel concentration distributions with planar laser induced fluorescence of tracer molecules that are added to a base fuel are commonly used in combustion research and development. It usually is assumed that the tracer concentration follows the parent fuel concentration if physical properties such as those determining evaporation are matched. As an example to address this general issue a computational study of combustion of biacetyl/iso-octane mixtures was performed to investigate how well the concentration of biacetyl represents the concentration of iso-octane. For premixed mixture conditions with flame propagation the spatial concentration profiles of the two species in the flame front are separated by 110 {micro}m at 1 bar and by 11 {micro}m at 10 bar. For practical applications this spatial separation is insignificantly small. However, for conditions that mimic ignition and combustion in diesel and HCCI-like operation the differences in tracer and fuel concentration can be significant, exceeding hundreds of percent. At low initial temperature biacetyl was found to be more stable whereas at higher temperature (>1000K) iso-octane is more stable. Similar findings were obtained for a multi-component fuel comprised of iso-octane, n-heptane, methylcyclohexane, and toluene. It may be assumed that similar differences can exist for other tracer/fuel combinations. Caution has therefore to be applied when interpreting PLIF measurements in homogeneous reaction conditions such as in HCCI engine studies.

  14. Tracers and Tracer Testing: Design, Implementation, Tracer Selection, and Interpretation Methods

    Energy Technology Data Exchange (ETDEWEB)

    G. Michael Shook; Shannon L.; Allan Wylie

    2004-01-01

    Conducting a successful tracer test requires adhering to a set of steps. The steps include identifying appropriate and achievable test goals, identifying tracers with the appropriate properties, and implementing the test as designed. When these steps are taken correctly, a host of tracer test analysis methods are available to the practitioner. This report discusses the individual steps required for a successful tracer test and presents methods for analysis. The report is an overview of tracer technology; the Suggested Reading section offers references to the specifics of test design and interpretation.

  15. Quantifying solute transport processes: are chemically "conservative" tracers electrically conservative?

    Science.gov (United States)

    Singha, Kamini; Li, Li; Day-Lewis, Frederick D.; Regberg, Aaron B.

    2012-01-01

    The concept of a nonreactive or conservative tracer, commonly invoked in investigations of solute transport, requires additional study in the context of electrical geophysical monitoring. Tracers that are commonly considered conservative may undergo reactive processes, such as ion exchange, thus changing the aqueous composition of the system. As a result, the measured electrical conductivity may reflect not only solute transport but also reactive processes. We have evaluated the impacts of ion exchange reactions, rate-limited mass transfer, and surface conduction on quantifying tracer mass, mean arrival time, and temporal variance in laboratory-scale column experiments. Numerical examples showed that (1) ion exchange can lead to resistivity-estimated tracer mass, velocity, and dispersivity that may be inaccurate; (2) mass transfer leads to an overestimate in the mobile tracer mass and an underestimate in velocity when using electrical methods; and (3) surface conductance does not notably affect estimated moments when high-concentration tracers are used, although this phenomenon may be important at low concentrations or in sediments with high and/or spatially variable cation-exchange capacity. In all cases, colocated groundwater concentration measurements are of high importance for interpreting geophysical data with respect to the controlling transport processes of interest.

  16. Lanthanide-based fluorescent tracers in complex media

    International Nuclear Information System (INIS)

    Brichart, Thomas

    2014-01-01

    Tracers are objects allowing the determination of the position or the distribution of a product; tracers are currently used in a great variety of domains. Despite the fact that each field has it's own specifications, it is possible to find tracers in medicine (contrast agents), anti-counterfeiting or geological exploration. We have developed lanthanide complex tracers for oil field injection waters. Those tracers, derived from the DOTA, have been detected at concentration lower than 1 ppb, thanks to a simple and compact apparatus. This detection has been made possible by the use of time-resolved fluorescence spectroscopy, this technique allows us to get rid of the background noise created by the intrinsic fluorescence of oil residues that are present in production waters. We also demonstrated how we can, through a reverse microemulsion synthesis, encapsulate several different dyes inside a single nanoparticle composed of a gold core and a silica shell. We showed as well, how those particles can be used as smart tracers to gather data, such as temperature, pH, solvents, etc. inside the well. Finally the use of lanthanides and scale inhibitors properties allowed us to create a simple and fast dosing protocol of such scale inhibitors in injection waters. This dosage will then allow the quick adjustment of their concentration inside each well. (author) [fr

  17. Performance Testing of Tracer Gas and Tracer Aerosol Detectors for use in Radionuclide NESHAP Compliance Testing

    Energy Technology Data Exchange (ETDEWEB)

    Fuehne, David Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lattin, Rebecca Renee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-28

    The Rad-NESHAP program, part of the Air Quality Compliance team of LANL’s Compliance Programs group (EPC-CP), and the Radiation Instrumentation & Calibration team, part of the Radiation Protection Services group (RP-SVS), frequently partner on issues relating to characterizing air flow streams. This memo documents the most recent example of this partnership, involving performance testing of sulfur hexafluoride detectors for use in stack gas mixing tests. Additionally, members of the Rad-NESHAP program performed a functional trending test on a pair of optical particle counters, comparing results from a non-calibrated instrument to a calibrated instrument. Prior to commissioning a new stack sampling system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniformity of tracer gas and aerosol mixing in the air stream. For these mix tests, tracer media (sulfur hexafluoride gas or liquid oil aerosol particles) are injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of these media concentrations must be under 20% when evaluated over the central 2/3 area of the stack or duct. The instruments which measure these air concentrations must be tested prior to the stack tests in order to ensure their linear response to varying air concentrations of either tracer gas or tracer aerosol. The instruments used in tracer gas and aerosol mix testing cannot be calibrated by the LANL Standards and Calibration Laboratory, so they would normally be sent off-site for factory calibration by the vendor. Operational requirements can prevent formal factory calibration of some instruments after they have been used in hazardous settings, e.g., within a radiological facility with potential airborne contamination. The performance tests described in this document are intended to demonstrate the reliable

  18. TracerLPM (Version 1): An Excel® workbook for interpreting groundwater age distributions from environmental tracer data

    Science.gov (United States)

    Jurgens, Bryant C.; Böhlke, J.K.; Eberts, Sandra M.

    2012-01-01

    TracerLPM is an interactive Excel® (2007 or later) workbook program for evaluating groundwater age distributions from environmental tracer data by using lumped parameter models (LPMs). Lumped parameter models are mathematical models of transport based on simplified aquifer geometry and flow configurations that account for effects of hydrodynamic dispersion or mixing within the aquifer, well bore, or discharge area. Five primary LPMs are included in the workbook: piston-flow model (PFM), exponential mixing model (EMM), exponential piston-flow model (EPM), partial exponential model (PEM), and dispersion model (DM). Binary mixing models (BMM) can be created by combining primary LPMs in various combinations. Travel time through the unsaturated zone can be included as an additional parameter. TracerLPM also allows users to enter age distributions determined from other methods, such as particle tracking results from numerical groundwater-flow models or from other LPMs not included in this program. Tracers of both young groundwater (anthropogenic atmospheric gases and isotopic substances indicating post-1940s recharge) and much older groundwater (carbon-14 and helium-4) can be interpreted simultaneously so that estimates of the groundwater age distribution for samples with a wide range of ages can be constrained. TracerLPM is organized to permit a comprehensive interpretive approach consisting of hydrogeologic conceptualization, visual examination of data and models, and best-fit parameter estimation. Groundwater age distributions can be evaluated by comparing measured and modeled tracer concentrations in two ways: (1) multiple tracers analyzed simultaneously can be evaluated against each other for concordance with modeled concentrations (tracer-tracer application) or (2) tracer time-series data can be evaluated for concordance with modeled trends (tracer-time application). Groundwater-age estimates can also be obtained for samples with a single tracer measurement at one

  19. Measuring SSRI occupancy of SERT using the novel tracer [123I]ADAM: a SPECT validation study

    International Nuclear Information System (INIS)

    Erlandsson, Kjell; Lui, Dominic; Townsend, Caroline E.; Ell, Peter J.; Sivananthan, Tharani; Mu, Song; Lucas, Richard; Spezzi, Andrea; Warrington, Steven

    2005-01-01

    Serotonergic brain regions play a crucial role in the modulation of emotion, and serotonergic dysfunction may contribute to several neurological disorders. [ 123 I]ADAM is a novel SPECT tracer which binds with high affinity to serotonin transporters (SERT). The objective of this study was to compare different methods for the quantification of tracer binding and to develop a simplified single-scan protocol for this tracer, as well as to investigate its potential for characterisation of the transporter occupancy versus plasma concentration curve of a selective serotonin re-uptake inhibitor (SSRI). Dynamic SPECT scans were performed on 16 healthy volunteers after administration of ∝150 MBq [ 123 I]ADAM. Data were acquired from the time of injection until ∝5.5 h after injection in 30- or 45-min sessions. Each subject was scanned twice: with and without pre-treatment with the SSRI citalopram in various dosage regimens. The plasma concentration of citalopram (C p ) was determined from venous samples. Images were reconstructed by filtered back-projection with scatter and attenuation correction. Tracer binding was quantified for midbrain, striatum and thalamus using cerebellum as a reference region. Quantification was done by kinetic modelling, graphical analysis and multi-linear regression, as well as by the ratio method, with binding potential (BP 2 ) as the outcome measure. The SERT occupancy by citalopram was determined relative to the baseline scan for each subject, and the occupancy versus C p curve was fitted with the E max model. The highest binding of [ 123 I]ADAM was in midbrain (mean baseline BP 2 ±SD=1.31±0.29), with lower binding in thalamus (0.79±0.16) and striatum (0.66±0.13). There was good agreement between BP 2 values obtained by different quantification methods. Using the ratio method, the best agreement with kinetic modelling was obtained with data from the time interval [200,260] min after injection. The fitting of the midbrain occupancy curve

  20. Tracer verification and monitoring of containment systems (II)

    International Nuclear Information System (INIS)

    Williams, C.V.; Dunn, S.D.; Lowry, W.E.

    1997-01-01

    A tracer verification and monitoring system, SEAtrace trademark, has been designed and field tested which uses gas tracers to evaluate, verify, and monitor the integrity of subsurface barriers. This is accomplished using an automatic, rugged, autonomous monitoring system combined with an inverse optimization code. A gaseous tracer is injected inside the barrier and an array of wells outside the barrier are monitored. When the tracer gas is detected, a global optimization code is used to calculate the leak parameters, including leak size, location, and when the leak began. The multipoint monitoring system operates in real-time, can be used to measure both the tracer gas and soil vapor contaminants, and is capable of unattended operation for long periods of time (months). The global optimization code searches multi-dimensional open-quotes spaceclose quotes to find the best fit for all of the input parameters. These parameters include tracer gas concentration histories from multiple monitoring points, medium properties, barrier location, and the source concentration. SEAtrace trademark does not attempt to model all of the nuances associated with multi-phase, multi-component flow, but rather, the inverse code uses a simplistic forward model which can provide results which are reasonably accurate. The system has calculated leak locations to within 0.5 meters and leak radii to within 0.12 meters

  1. Measuring SSRI occupancy of SERT using the novel tracer [{sup 123}I]ADAM: a SPECT validation study

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, Kjell; Lui, Dominic; Townsend, Caroline E.; Ell, Peter J. [Middlesex Hospital, Institute of Nuclear Medicine, University College London, London (United Kingdom); Sivananthan, Tharani; Mu, Song; Lucas, Richard [Lilly Research Centre, Eli Lilly and Company, Windlesham, Surrey (United Kingdom); Spezzi, Andrea; Warrington, Steven [Central Middlesex Hospital, Hammersmith Medicines Research, London (United Kingdom)

    2005-11-01

    Serotonergic brain regions play a crucial role in the modulation of emotion, and serotonergic dysfunction may contribute to several neurological disorders. [{sup 123}I]ADAM is a novel SPECT tracer which binds with high affinity to serotonin transporters (SERT). The objective of this study was to compare different methods for the quantification of tracer binding and to develop a simplified single-scan protocol for this tracer, as well as to investigate its potential for characterisation of the transporter occupancy versus plasma concentration curve of a selective serotonin re-uptake inhibitor (SSRI). Dynamic SPECT scans were performed on 16 healthy volunteers after administration of {proportional_to}150 MBq [{sup 123}I]ADAM. Data were acquired from the time of injection until {proportional_to}5.5 h after injection in 30- or 45-min sessions. Each subject was scanned twice: with and without pre-treatment with the SSRI citalopram in various dosage regimens. The plasma concentration of citalopram (C{sub p}) was determined from venous samples. Images were reconstructed by filtered back-projection with scatter and attenuation correction. Tracer binding was quantified for midbrain, striatum and thalamus using cerebellum as a reference region. Quantification was done by kinetic modelling, graphical analysis and multi-linear regression, as well as by the ratio method, with binding potential (BP{sub 2}) as the outcome measure. The SERT occupancy by citalopram was determined relative to the baseline scan for each subject, and the occupancy versus C{sub p} curve was fitted with the E{sub max} model. The highest binding of [{sup 123}I]ADAM was in midbrain (mean baseline BP{sub 2}{+-}SD=1.31{+-}0.29), with lower binding in thalamus (0.79{+-}0.16) and striatum (0.66{+-}0.13). There was good agreement between BP{sub 2} values obtained by different quantification methods. Using the ratio method, the best agreement with kinetic modelling was obtained with data from the time interval

  2. Fluorescence guided surgery and tracer-dose, fact or fiction?

    International Nuclear Information System (INIS)

    KleinJan, Gijs H.; Olmos, Renato A.V.; Bunschoten, Anton; Berg, Nynke S. van den; Klop, W.M.C.; Horenblas, Simon; Poel, Henk G. van der; Wester, Hans-Juergen; Leeuwen, Fijs W.B. van

    2016-01-01

    Fluorescence guidance is an upcoming methodology to improve surgical accuracy. Challenging herein is the identification of the minimum dose at which the tracer can be detected with a clinical-grade fluorescence camera. Using a hybrid tracer such as indocyanine green (ICG)- 99m Tc-nanocolloid, it has become possible to determine the accumulation of tracer and correlate this to intraoperative fluorescence-based identification rates. In the current study, we determined the lower detection limit of tracer at which intraoperative fluorescence guidance was still feasible. Size exclusion chromatography (SEC) provided a laboratory set-up to analyze the chemical content and to simulate the migratory behavior of ICG-nanocolloid in tissue. Tracer accumulation and intraoperative fluorescence detection findings were derived from a retrospective analysis of 20 head-and-neck melanoma patients, 40 penile and 20 prostate cancer patients scheduled for sentinel node (SN) biopsy using ICG- 99m Tc-nanocolloid. In these patients, following tracer injection, single photon emission computed tomography fused with computed tomography (SPECT/CT) was used to identify the SN(s). The percentage injected dose (% ID), the amount of ICG (in nmol), and the concentration of ICG in the SNs (in μM) was assessed for SNs detected on SPECT/CT and correlated with the intraoperative fluorescence imaging findings. SEC determined that in the hybrid tracer formulation, 41 % (standard deviation: 12 %) of ICG was present in nanocolloid-bound form. In the SNs detected using fluorescence guidance a median of 0.88 % ID was present, compared to a median of 0.25 % ID in the non-fluorescent SNs (p-value < 0.001). The % ID values could be correlated to the amount ICG in a SN (range: 0.003-10.8 nmol) and the concentration of ICG in a SN (range: 0.006-64.6 μM). The ability to provide intraoperative fluorescence guidance is dependent on the amount and concentration of the fluorescent dye accumulated in the lesion(s) of

  3. Rate equations for tracer studies in recirculating reactors

    Energy Technology Data Exchange (ETDEWEB)

    Happel, J [Columbia Univ., New York (USA). Dept. of Chemical Engineering

    1974-10-01

    The employment of isotopic tracers is a useful technique for gaining insight into the rate controlling steps of a complex chemical reaction such as is frequently encountered in heterogeneous catalysis. An effective procedure has been to superpose tracer transfer on a reaction which is occurring under steady state conditions. If tracer transfer is employed in this fashion it is often possible to assess the individual step velocities in an assumed reaction mechanism. If transient transfer of tracer is now introduced it is possible in addition to estimate surface concentrations of chemisorbed species. The purpose of the present paper is to present the mathematical relationships involved when transfer of the tracer is not differential in the investigation. For this purpose a simple example is chosen to illustrate the various possibilities involved.

  4. Rate equations for tracer studies in recirculatinng reactors

    International Nuclear Information System (INIS)

    Happel, J.

    1974-01-01

    The employment of isotopic tracers is a useful technique for gaining insight into the rate controlling steps of a complex chemical reaction such as is frequently encountered in heterogeneous catalysis. An effective procedure has been to superpose tracer transfer on a reaction which is occurring under steady state conditions. If tracer transfer is employed in this fashion it is often possible to assess the individual step velocities in an assumed reaction mechanism. If transient transfer of tracer is now introduced it is possible in addition to estimate surface concentrations of chemisorbed species. The purpose of the present paper is to present the mathematical relationships involved when transfer of the tracer is not differential in the investigation. For this purpose a simple example is chosen to illustrate the various possibilities involved. (auth.)

  5. Measurements of waste tank passive ventilation rates using tracer gases

    International Nuclear Information System (INIS)

    Huckaby, J.L.; Olsen, K.B.; Sklarew, D.S.; Evans, J.C.; Remund, K.M.

    1997-09-01

    This report presents the results of ventilation rate studies of eight passively ventilated high-level radioactive waste tanks using tracer gases. Head space ventilation rates were determined for Tanks A-101, AX-102, AX-103, BY-105, C-107, S-102, U-103, and U-105 using sulfur hexafluoride (SF 6 ) and/or helium (He) as tracer gases. Passive ventilation rates are needed for the resolution of several key safety issues. These safety issues are associated with the rates of flammable gas production and ventilation, the rates at which organic salt-nitrate salt mixtures dry out, and the estimation of organic solvent waste surface areas. This tracer gas study involves injecting a tracer gas into the tank headspace and measuring its concentration at different times to establish the rate at which the tracer is removed by ventilation. Tracer gas injection and sample collection were performed by SGN Eurisys Service Corporation and/or Lockheed Martin Hanford Corporation, Characterization Project Operations. Headspace samples were analyzed for He and SF 6 by Pacific Northwest National Laboratory (PNNL). The tracer gas method was first demonstrated on Tank S-102. Tests were conducted on Tank S-102 to verify that the tracer gas was uniformly distributed throughout the tank headspace before baseline samples were collected, and that mixing was sufficiently vigorous to maintain an approximately uniform distribution of tracer gas in the headspace during the course of the study. Headspace samples, collected from a location about 4 in away from the injection point and 15, 30, and 60 minutes after the injection of He and SF 6 , indicated that both tracer gases were rapidly mixed. The samples were found to have the same concentration of tracer gases after 1 hour as after 24 hours, suggesting that mixing of the tracer gas was essentially complete within 1 hour

  6. Natural tracer profiles across argillaceous formations

    International Nuclear Information System (INIS)

    Mazurek, Martin; Alt-Epping, Peter; Bath, Adrian; Gimmi, Thomas; Niklaus Waber, H.; Buschaert, Stephane; Canniere, Pierre De; Craen, Mieke De; Gautschi, Andreas; Savoye, Sebastien; Vinsot, Agnes; Wemaere, Isabelle; Wouters, Laurent

    2011-01-01

    shapes of the profiles can be explained by diffusion acting as the dominant transport process over periods of several thousands to several millions of years and at the length scales of the profiles. Transport by advection has a negligible influence on the observed profiles at most sites, as can be shown by estimating the maximum advection velocities that still give acceptable fits of the model with the data. The advantages and disadvantages of different conservative tracers are also assessed. The anion Cl - is well suited as a natural tracer in aquitards, because its concentration varies considerably in environmental waters. It can easily be measured, although the uncertainty regarding the fraction of the pore space that is accessible to anions in clays remains an issue. The stable water isotopes are also well suited, but they are more difficult to measure and their values generally exhibit a smaller relative range of variation. Chlorine isotopes (δ 37 Cl) and He are more difficult to interpret because initial and boundary conditions cannot easily be constrained by independent evidence. It is also shown that the existence of perturbing events such as the activation of aquifers due to uplift and erosion, leading to relatively sharp changes of boundary conditions, can be considered as a pre-requisite to obtain well-interpretable tracer signatures. On the other hand, gradual changes of boundary conditions are more difficult to parameterise and so may preclude a clear interpretation.

  7. Experiments to Evaluate and Implement Passive Tracer Gas Methods to Measure Ventilation Rates in Homes

    Energy Technology Data Exchange (ETDEWEB)

    Lunden, Melissa [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Heredia, Elizabeth [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cohn, Sebastian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Dickerhoff, Darryl [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Noris, Federico [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Logue, Jennifer [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hotchi, Toshifumi [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-10-01

    This report documents experiments performed in three homes to assess the methodology used to determine air exchange rates using passive tracer techniques. The experiments used four different tracer gases emitted simultaneously but implemented with different spatial coverage in the home. Two different tracer gas sampling methods were used. The results characterize the factors of the execution and analysis of the passive tracer technique that affect the uncertainty in the calculated air exchange rates. These factors include uncertainties in tracer gas emission rates, differences in measured concentrations for different tracer gases, temporal and spatial variability of the concentrations, the comparison between different gas sampling methods, and the effect of different ventilation conditions.

  8. Tumoral tracers

    International Nuclear Information System (INIS)

    Camargo, E.E.

    1979-01-01

    Direct tumor tracers are subdivided in the following categories:metabolite tracers, antitumoral tracers, radioactive proteins and cations. Use of 67 Ga-citrate as a clinically important tumoral tracer is emphasized and gallium-67 whole-body scintigraphy is discussed in detail. (M.A.) [pt

  9. COMPARISON OF THREE TRACER TESTS AT THE RAFT RIVER GEOTHERMAL SITE

    Energy Technology Data Exchange (ETDEWEB)

    Earl D Mattson; Mitchell Plummer; Carl Palmer; Larry Hull; Samantha Miller; Randy Nye

    2011-02-01

    Three conservative tracer tests have been conducted through the Bridge Fault fracture zone at the Raft River Geothermal (RRG) site. All three tests were conducted between injection well RRG-5 and production wells RRG-1 (790 m distance) and RRG-4 (740 m distance). The injection well is used during the summer months to provide pressure support to the production wells. The first test was conducted in 2008 using 136 kg of fluorescein tracer. Two additional tracers were injected in 2010. The first 2010 tracer injected was 100 kg fluorescein disodium hydrate salt on June, 21. The second tracer (100 kg 2,6-naphthalene disulfonic acid sodium salt) was injected one month later on July 21. Sampling of the two productions wells is still being performed to obtain the tail end of the second 2010 tracer test. Tracer concentrations were measured using HPLC with a fluorescence detector. Results for the 2008 test, suggest 80% tracer recover at the two production wells. Of the tracer recovered, 85% of tracer mass was recovered in well RRG-4 indicating a greater flow pathway connection between injection well and RRG-4 than RRG-1. Fluorescein tracer results appear to be similar between the 2008 and 2010 tests for well RRG-4 with peak concentrations arriving approximately 20 days after injection despite the differences between the injection rates for the two tests (~950 gpm to 475 gpm) between the 2008 and 2010. The two 2010 tracer tests will be compared to determine if the results support the hypothesis that rock contraction along the flow pathway due to the 55 oC cooler water injection alters the flow through the ~140 oC reservoir.

  10. Fifty years of radiochemical tracers

    International Nuclear Information System (INIS)

    Evans, E.A.

    1992-01-01

    During the past 50 years radiochemical tracers, usually in the form of isotopically labelled organic compounds, have been essential tools to further advance our knowledge at the frontiers of a great variety of scientific developments in the life sciences. This plenary lecture reviews necessarily selected highlights in the synthesis and applications of such radiochemical tracers. Included are examples where important advances, made possible by using radiochemicals, have contributed to improving the quality of life on this planet. The principal radioisotopes involved, 14 C, 3 H, 35 S, 32 P, 125 I, are all relatively safe to handle and are commercially available at maximum theoretical specific activity (carrier free). The compounds labeled with these radioisotopes are used in many fields of research which include biosynthesis and biotechnology studies, cell biology, drug metabolism, clinical research and environmental applications, and are briefly reviewed. (author). 55 refs

  11. Inferring Groundwater Age in an Alluvial Aquifer from Tracer Concentrations in the Stream - Little Wind River, Wyoming

    Science.gov (United States)

    Goble, D.; Gardner, W. P.; Naftz, D. L.; Solder, J. E.

    2017-12-01

    We use environmental tracers: CFC's, SF6, and 222Rn measured in stream water to determine volume and mean age of groundwater discharging to the Little Wind River, near Riverton, Wyoming. Samples of 222Rn were collected every 200 m along a 2 km reach, surrounding a known groundwater discharge zone. Nearby groundwater wells, in-stream piezometers and seepage meters were sampled for 222Rn, CFC's and SF6. Tracer concentrations measured in groundwater and in-stream piezometers were used to estimate the mean age of the subsurface system. High resolution 222Rn samples were used to determine the location and volume of groundwater inflow using a model of instream transport that includes radioactive decay and gas exchange with the atmosphere. The age of groundwater entering the stream was then estimated from in-stream measured CFC and SF6 concentrations using a new coupled stream transport and lumped-parameter groundwater age model. Ages derived from in-stream measurements were then compared to the age of subsurface water measured in piezometers, seepage meters, and groundwater wells. We then asses the ability of groundwater age inferred from in-stream samples to provide constraint on the age of the subsurface discharge to the stream. The ability to asses groundwater age from in-stream samples can provide a convenient method to constrain the regional distribution of groundwater circulation rates when groundwater sampling is challenging or wells are not in place.

  12. Interpretation of Water Tracer Simulation in the H-1 Segment of the Gullfaks Field

    Energy Technology Data Exchange (ETDEWEB)

    Moid, Farrukh

    2000-07-01

    This thesis describes the water tracer simulation in the H-1 segment of the Gullfaks field. Three passive water tracer slugs were injected from the two producing wells during water flooding, pressure maintenance and reservoir monitoring program in the Gullfaks field. The same program is considered in this thesis. Computer Modelling Group's (CMG) simulator STARS is used for the general reservoir simulation and a separate module for tracer flow (ITRC-SIM) which is incorporated in the STARS and developed at Institute For Energy (IFE) is used for the tracer simulation. Water cut and tracer concentration data are used in history matching of the field. History matching is performed by changing the transmissibility and permeability of different layers; also the effect of changing saturations near the well bore on history matching is examined. It is noted that water cut is sensitive to transmissibility of the layers and the saturation around the well bore. Tracers are found to be moving in the most permeable layers. The corresponding history matching of water and tracer production shows a severe loss of first tracer injected because of imbibition process. Water phase velocity and areal communication between different wells are determined. Advance numerical features of tracer module ITRC-SIM such as flux limiting scheme and grid refinement scheme are evaluated and are found to be an important tool for reducing the numerical smearing. The effects of dispersion and diffusion on tracer response curve are also evaluated. Dispersion makes the tracer concentration curve smeared. Simulation results of water cut and tracer concentration show a good history match for this reservoir. The improved simulation model and the tracer module for this reservoir can be used for the prediction of future performance of the reservoir and interpretation of the tracer behaviour in the reservoir. (author)

  13. Elevated source SF6-tracer dispersion experiments in the Copenhagen area. Preliminary results II

    International Nuclear Information System (INIS)

    Gryning, S.E.; Lyck, E.

    1980-01-01

    The results from 10 experiments, performed in neutral to unstable meteorological conditions, are reported from an ongoing series of elevated-source, urban-scale tracer dispersion experiments in the Copenhagen area. The tracer is released at a height of 115 m from the TV-tower in GLADSAXE, a suburb of Copenhagen, with tracer sampling units positioned at ground-level in 1 to 3 crosswind series, 2 to 6 km downwind of the tower. The lateral dispersion parameter, sigma(y), was estimated from the measured tracer concentration distribution and compared with values of sigma(y), computed by 1) methods based on wind variance measured during the experiments and 2) methods based on a stability classification of the atmospheric conditions. The wind-variance based methods proved superior in predicting the variation of sigma(y) compared with the stability based methods. Moreover, some of the former methods produced significantly biased estimates of sigma(y). The measured tracer concentration distributions were also crosswind integrated, chi(CWI). Estimates of chi(CWI) were computed using sigma (z) -values derived from the aforementioned computations assuming a Gaussian-type vertical tracer concentration distribution. A comparison is measured and calculated values of chi(CWI) showed no significant differences in the ability of the methods to predict the variation of chi(CWI). Only one method, the EPA, came out with a mean fractional error outside the range +-20% which constitutes the uncertainty in the absolute tracer concentration associated with the calibration of the gas chromatograph for tracer analysis

  14. Secondary poisoning of cadmium, copper and mercury: implications for the Maximum Permissible Concentrations and Negligible Concentrations in water, sediment and soil

    NARCIS (Netherlands)

    Smit CE; Wezel AP van; Jager T; Traas TP; CSR

    2000-01-01

    The impact of secondary poisoning on the Maximum Permissible Concentrations (MPCs) and Negligible Concentrations (NCs) of cadmium, copper and mercury in water, sediment and soil have been evaluated. Field data on accumulation of these elements by fish, mussels and earthworms were used to derive

  15. Maximum solid concentrations of coal water slurries predicted by neural network models

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Jun; Li, Yanchang; Zhou, Junhu; Liu, Jianzhong; Cen, Kefa

    2010-12-15

    The nonlinear back-propagation (BP) neural network models were developed to predict the maximum solid concentration of coal water slurry (CWS) which is a substitute for oil fuel, based on physicochemical properties of 37 typical Chinese coals. The Levenberg-Marquardt algorithm was used to train five BP neural network models with different input factors. The data pretreatment method, learning rate and hidden neuron number were optimized by training models. It is found that the Hardgrove grindability index (HGI), moisture and coalification degree of parent coal are 3 indispensable factors for the prediction of CWS maximum solid concentration. Each BP neural network model gives a more accurate prediction result than the traditional polynomial regression equation. The BP neural network model with 3 input factors of HGI, moisture and oxygen/carbon ratio gives the smallest mean absolute error of 0.40%, which is much lower than that of 1.15% given by the traditional polynomial regression equation. (author)

  16. Halon-1301, a new Groundwater Age Tracer

    Science.gov (United States)

    Beyer, Monique; van der Raaij, Rob; Morgenstern, Uwe; Jackson, Bethanna

    2015-04-01

    concentration of Halon-1301, which indicates absence of local anthropogenic or geologic sources (contamination), despite some samples showing CFC contamination. We found agreement of 71% of mean age estimates with ages inferred from tritium and SF6 within +/- 2 years, for samples where direct age comparison could be made. The remaining sites showed reduced concentrations of Halon-1301 along with reduced concentrations of CFCs. The reasons for this need to be further assessed, but are likely caused by sorption or degradation of Halon-1301. Further Halon-1301 studies are planned covering various hydrogeologic situations, land use practises, and redox conditions to evaluate the potential of Halon-1301 as groundwater tracer, and to elucidate the causes for reduced Halon-1301 concentrations. Acknowledgements Greater Wellington Regional Council, especially S. Tidswell, is thanked for support and organisation of the sampling of the groundwater wells. This study is part of a PhD supported by GNS Science as part of the Smart Aquifer Characterization program funded by the New Zealand Ministry for Science and Innovation (http://www.smart-project.info/). References Beyer, M., van der Raaij, R., Morgenstern, U., Jackson, B. (2014) Potential groundwater age tracer found: Halon-1301 (CF3Br), as previously identified as CFC-13 (CF3Cl), Water Resources Research. Busenberg, E. and Plummer, L.N. (2008) Dating groundwater with trifluoromethyl sulfurpentafluoride (SF5CF3), sulfurhexafluoride (SF6), CF3Cl (CFC-13) & CF2CL2 (CFC-12), Water Resources Research 44

  17. Transuranic and tracer simulant resuspension. [/sup 238/Pu, /sup 239/Pu, /sup 240/Pu

    Energy Technology Data Exchange (ETDEWEB)

    Sehmel, G. A.

    1977-07-01

    Plutonium resuspension results are summarized for experiments conducted at Rocky Flats, onsite on the Hanford reservation, and for winds blowing from offsite onto the Hanford reservation near the Prosser barricade boundary. In each case, plutonium resuspension was shown by increased airborne plutonium concentrations as a function of either wind speed or as compared to fallout levels. All measured airborne concentrations were below maximum permissible concentrations (MPC). Both plutonium and cesium concentrations on airborne soil were normalized by the quantity of airborne soil sampled. Airborne radionuclide concentrations in ..mu..Ci/g were related to published values for radionuclide concentrations on surface soils. For this ratio of radionuclide concentration per gram on airborne soil divided by that for ground surface soil, there are eight orders of magnitude uncertainty from 10/sup -4/ to 10/sup 4/. Horizontal plutonium fluxes on airborne nonrespirable soils at all three sites were bracketed within the same three to four orders of magnitude from 10/sup -7/ to 10/sup -3/ ..mu..Ci/(m/sup 2/ day) for plutonium-239 and 10/sup -8/ to 10/sup -5/ ..mu..Ci/(m/sup 2/ day) for plutonium-238. These are the entire experimental base for nonrespirable airborne plutonium transport. Airborne respirable plutonium-239 concentrations increased with wind speed for a southeast wind direction coming from offsite near the Hanford reservation Prosser barricade. Airborne plutonium fluxes on nonrespirable particles had isotopic ratios, /sup 240/Pu//sup 239 +240/Pu, similar to weapons grade plutonium rather than fallout plutonium. Resuspension rates were summarized for controlled inert particle tracer simulant experiments. Wind resuspension rates for tracers increased with wind speed to about the fifth power.

  18. Comparison of concentration pulse and tracer pulse chromatography: experimental determination of eluent uptake by bridged-ethylene hybrid ultra high performance liquid chromatography packings

    Science.gov (United States)

    Excess volume isotherms of acetonitrile and methanol sorbed on a C18 BEH UHPLC packing were determined over a range of pressure, temperature, flow rate and eluent composition. The isotherm measurements were carried out by two independent experimental methods, viz., concentration pulse and tracer pul...

  19. Benefits of important industrial tracer applications in the GDR

    International Nuclear Information System (INIS)

    Leonhardt, J.W.; Goeldner, R.; Koennecke, H.G.; Kupsch, H.; Luther, D.; Otto, R.; Reinhardt, R.; Ulrich, H.

    1990-01-01

    Tracers can be used to label substances or objects in order to discriminate between them, to follow their movement, to record changes of concentration and distribution between phases, etc. The main advantages of tracer investigations are the contactless recording of signals without influencing the observed process (also under rigorous operation conditions), the high detection sensitivity, the large number of available tracer nuclides (problems of all branches of industry can be solved) and the fact that tracer investigation can be carried out on operating production units, so that they provide valuable checks of the validity of design and process data. The cost-to-benefit ratio can be as low as 1:50. In the following some selected examples of tracer applications and their benefits will be presented. (orig./BBR) [de

  20. Using Tracer Technology to Characterize Contaminated Pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Maresca, Joseph, W., Jr., Ph.D.; Bratton, Wesley, L., Ph.D., P.E.; Dickerson, Wilhelmina; Hales, Rochelle

    2005-12-30

    The Pipeline Characterization Using Tracers (PCUT) technique uses conservative and partitioning, reactive or other interactive tracers to remotely determine the amount of contaminant within a run of piping or ductwork. The PCUT system was motivated by a method that has been successfully used to characterize subsurface soil contaminants and is similar in operation to that of a gas chromatography column. By injecting a ?slug? of both conservative and partitioning tracers at one end (or section) of the piping and measuring the time history of the concentration of the tracers at the other end (or another section) of the pipe, the presence, location, and amount of contaminant within the pipe or duct can be determined. The tracers are transported along the pipe or duct by a gas flow field, typically air or nitrogen, which has a velocity that is slow enough so that the partitioning tracer has time to interact with the contaminant before the tracer slug completely passes over the contaminate region. PCUT not only identifies the presence of contamination, it also can locate the contamination along the pipeline and quantify the amount of residual. PCUT can be used in support of deactivation and decommissioning (D&D) of piping and ducts that may have been contaminated with hazardous chemicals such as chlorinated solvents, petroleum products, radioactive materials, or heavy metals, such as mercury.

  1. Investigating sources and pathways of perfluoroalkyl acids (PFAAs) in aquifers in Tokyo using multiple tracers

    International Nuclear Information System (INIS)

    Kuroda, Keisuke; Murakami, Michio; Oguma, Kumiko; Takada, Hideshige; Takizawa, Satoshi

    2014-01-01

    We employed a multi-tracer approach to investigate sources and pathways of perfluoroalkyl acids (PFAAs) in urban groundwater, based on 53 groundwater samples taken from confined aquifers and unconfined aquifers in Tokyo. While the median concentrations of groundwater PFAAs were several ng/L, the maximum concentrations of perfluorooctane sulfonate (PFOS, 990 ng/L), perfluorooctanoate (PFOA, 1800 ng/L) and perfluorononanoate (PFNA, 620 ng/L) in groundwater were several times higher than those of wastewater and street runoff reported in the literature. PFAAs were more frequently detected than sewage tracers (carbamazepine and crotamiton), presumably owing to the higher persistence of PFAAs, the multiple sources of PFAAs beyond sewage (e.g., surface runoff, point sources) and the formation of PFAAs from their precursors. Use of multiple methods of source apportionment including principal component analysis–multiple linear regression (PCA–MLR) and perfluoroalkyl carboxylic acid ratio analysis highlighted sewage and point sources as the primary sources of PFAAs in the most severely polluted groundwater samples, with street runoff being a minor source (44.6% sewage, 45.7% point sources and 9.7% street runoff, by PCA–MLR). Tritium analysis indicated that, while young groundwater (recharged during or after the 1970s, when PFAAs were already in commercial use) in shallow aquifers (< 50 m depth) was naturally highly vulnerable to PFAA pollution, PFAAs were also found in old groundwater (recharged before the 1950s, when PFAAs were not in use) in deep aquifers (50–500 m depth). This study demonstrated the utility of multiple uses of tracers (pharmaceuticals and personal care products; PPCPs, tritium) and source apportionment methods in investigating sources and pathways of PFAAs in multiple aquifer systems. - Highlights: • Aquifers in Tokyo had high levels of perfluoroalkyl acids (up to 1800 ng/L). • PFAAs were more frequently detected than sewage-tracer

  2. Investigating sources and pathways of perfluoroalkyl acids (PFAAs) in aquifers in Tokyo using multiple tracers

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, Keisuke, E-mail: keisukekr@gmail.com [Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656 (Japan); Murakami, Michio [Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro, Tokyo 153-8505 (Japan); Oguma, Kumiko [Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656 (Japan); Takada, Hideshige [Laboratory of Organic Geochemistry (LOG), Institute of Symbiotic Science and Technology, Tokyo University of Agriculture and Technology, Fuchu, Tokyo 183-8509 (Japan); Takizawa, Satoshi [Department of Urban Engineering, Graduate School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656 (Japan)

    2014-08-01

    We employed a multi-tracer approach to investigate sources and pathways of perfluoroalkyl acids (PFAAs) in urban groundwater, based on 53 groundwater samples taken from confined aquifers and unconfined aquifers in Tokyo. While the median concentrations of groundwater PFAAs were several ng/L, the maximum concentrations of perfluorooctane sulfonate (PFOS, 990 ng/L), perfluorooctanoate (PFOA, 1800 ng/L) and perfluorononanoate (PFNA, 620 ng/L) in groundwater were several times higher than those of wastewater and street runoff reported in the literature. PFAAs were more frequently detected than sewage tracers (carbamazepine and crotamiton), presumably owing to the higher persistence of PFAAs, the multiple sources of PFAAs beyond sewage (e.g., surface runoff, point sources) and the formation of PFAAs from their precursors. Use of multiple methods of source apportionment including principal component analysis–multiple linear regression (PCA–MLR) and perfluoroalkyl carboxylic acid ratio analysis highlighted sewage and point sources as the primary sources of PFAAs in the most severely polluted groundwater samples, with street runoff being a minor source (44.6% sewage, 45.7% point sources and 9.7% street runoff, by PCA–MLR). Tritium analysis indicated that, while young groundwater (recharged during or after the 1970s, when PFAAs were already in commercial use) in shallow aquifers (< 50 m depth) was naturally highly vulnerable to PFAA pollution, PFAAs were also found in old groundwater (recharged before the 1950s, when PFAAs were not in use) in deep aquifers (50–500 m depth). This study demonstrated the utility of multiple uses of tracers (pharmaceuticals and personal care products; PPCPs, tritium) and source apportionment methods in investigating sources and pathways of PFAAs in multiple aquifer systems. - Highlights: • Aquifers in Tokyo had high levels of perfluoroalkyl acids (up to 1800 ng/L). • PFAAs were more frequently detected than sewage-tracer

  3. Use of sulfur hexafluoride and perfluorocarbon tracers in plutonium storage containers for leak detection

    International Nuclear Information System (INIS)

    Kung, J.K.

    1998-05-01

    This study involves an investigation of the feasibility of a tracer-based leak detection system for long-term interim plutonium storage. In particular, a protocol has been developed based on the use of inert tracers with varying concentrations in order to open-quotes fingerprintclose quotes or open-quotes tagclose quotes specific containers. A particular combination of tracers at specific ratios could be injected into the free volume of each container, allowing for the detection of leaks as well as determination of the location of leaking containers. Based on plutonium storage considerations, sulfur hexafluoride and four perfluorocarbon tracers were selected and should allow a wide range of viable fingerprinting combinations. A open-quotes high-lowclose quotes protocol which uses two distinct chromatographic peak areas or concentration levels, is recommended. Combinations of air exchange rates, detection durations, and detectability limits are examined in order to predict minimum tracer concentrations required for injection in storage containers

  4. Tracer concentration contours in grain lattice and grain boundary diffusion

    International Nuclear Information System (INIS)

    Kim, Y. S.; Olander, D. R.

    1997-01-01

    Grain boundary diffusion plays a significant role in fission gas release, which is one of the crucial processes dominating nuclear fuel performance. Gaseous fission products such as Xe and Kr generated during nuclear fission have to diffuse in the grain lattice and the boundary inside fuel pellets before they reach the open spaces in a fuel rod. These processes can be studied by 'tracer diffusion' techniques, by which grain boundary diffusivity can be estimated and directly used for low burn-up fission gas release analysis. However, only a few models accounting for the both processes are available and mostly handle them numerically due to mathematical complexity. Also the numerical solution has limitations in a practical use. In this paper, an approximate analytical solution in case of stationary grain boundary in a polycrystalline solid is developed for the tracer diffusion techniques. This closed-form solution is compared to available exact and numerical solutions and it turns out that it makes computation not only greatly easier but also more accurate than previous models. It can be applied to theoretical modelings for low burn-up fission gas release phenomena and experimental analyses as well, especially for PIE (post irradiation examination). (author)

  5. Toxicity of fluorescent tracers and their degradation byproducts

    Directory of Open Access Journals (Sweden)

    Philippe Gombert

    2017-01-01

    Full Text Available Tracer tests are frequently used to delineate catchment area of water supply springs in karstic zones. In the karstic chalk of Normandy, the main tracers used are fluorescent: uranine, sulforhodamine B, naphtionate, and Tinopal®. In this area, a statistical analysis shows that less than half of the injected tracers joins the monitored restitution points and enters the drinking water system where they undergo chlorination. Most of the injected tracers is absorbed in the rock matrix or is thrown out of the aquifer via karstic springs: then it can join superficial waters where it is degraded due to the sun and air action. The paper presents firstly the laboratory degradation of a first batch of fluorescent tracers in contact with chlorine, in order to simulate their passage through a water treatment system for human consumption. A second batch of the same tracers is subjected to agents of natural degradation: ultraviolet illumination, sunlight and air sparging. Most tracers is degraded, and toxicity and ecotoxicity tests (on rats, daphniae and algae are performed on degradation byproducts. These tests do not show any acute toxicity but a low to moderate ecotoxicity. In conclusion, the most used fluorescent tracers of the Normandy karstic chalk and their artificial and natural degradation byproducts do not exhibit significant toxicity to humans and the aquatic environment, at the concentrations generally noted at the restitution points.

  6. Transdiaphragmatic transport of tracer albumin from peritoneal to pleural liquid measured in rats.

    Science.gov (United States)

    Lai-Fook, Stephen J; Houtz, Pamela K; Jones, Philip D

    2005-12-01

    In conscious Wistar-Kyoto rats, we studied the uptake of radioactive tracer (125)I-albumin into the pleural space and circulation after intraperitoneal (IP) injections with 1 or 5 ml of Ringer solution (3 g/dl albumin). Postmortem, we sampled pleural liquid, peritoneal liquid, and blood plasma 2-48 h after IP injection and measured their radioactivity and protein concentration. Tracer concentration was greater in pleural liquid than in plasma approximately 3 h after injection with both IP injection volumes. This behavior indicated transport of tracer through the diaphragm into the pleural space. A dynamic analysis of the tracer uptake with 5-ml IP injections showed that at least 50% of the total pleural flow was via the diaphragm. A similar estimate was derived from an analysis of total protein concentrations. Both estimates were based on restricted pleural capillary filtration and unrestricted transdiaphragmatic transport. The 5-ml IP injections did not change plasma protein concentration but increased pleural and peritoneal protein concentrations from control values by 22 and 30%, respectively. These changes were consistent with a small (approximately 8%) increase in capillary filtration and a small (approximately 20%) reduction in transdiaphragmatic flow from control values, consistent with the small (3%) decrease in hydration measured in diaphragm muscle. Thus the pleural uptake of tracer via the diaphragm with the IP injections occurred by the near-normal transport of liquid and protein.

  7. Tracer-tracer relations as a tool for research on polar ozone loss

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Rolf

    2010-07-01

    The report includes the following chapters: (1) Introduction: ozone in the atmosphere, anthropogenic influence on the ozone layer, polar stratospheric ozone loss; (2) Tracer-tracer relations in the stratosphere: tracer-tracer relations as a tool in atmospheric research; impact of cosmic-ray-induced heterogeneous chemistry on polar ozone; (3) quantifying polar ozone loss from ozone-tracer relations: principles of tracer-tracer correlation techniques; reference ozone-tracer relations in the early polar vortex; impact of mixing on ozone-tracer relations in the polar vortex; impact of mesospheric intrusions on ozone-tracer relations in the stratospheric polar vortex calculation of chemical ozone loss in the arctic in March 2003 based on ILAS-II measurements; (4) epilogue.

  8. Thin-source concentration dependent diffusion

    International Nuclear Information System (INIS)

    Eng, G.

    1978-01-01

    The diffusion of (Ca ++ ) in NaCl has been measured for various diffusion times and for the temperature range (575 0 to 775 0 C), using a thin-source of 45 Ca tracer, rectangular geometry, and serial sectioning. The pre-diffusion surface concentration was approximately 3 x 10 16 (Ca)-atoms/cm 2 , which, for an average penetration depth of 100 to 300 μm, produces a maximum (post-diffusion) impurity concentration comparable to or greater than the intrinsic cation vacancy concentration. The high-temperature function closely matches the D 0 (T) function obtained from low impurity concentration experiments. The lower-temperature function, combined with the sudden failure of the D(C) = D 0 (1 + [C] + 0.5[C] 2 ) function at these lower temperatures, indicates the onset of a second diffusion process, one which would operate only at extremely high impurity concentrations. This low-temperature behavior is shown to be consistent with a breakdown of the conditions assumed for vacancy equilibrium

  9. Evaluation of maximum radionuclide concentration from decay chains migration in aquifers

    International Nuclear Information System (INIS)

    Aquino Branco, O.E. de.

    1983-01-01

    The mathematical formulation of the mechanisms involved in the transport of contaminants in aquifers is presented. The methodology employed is described. A method of calculation the maximum concentration of radionuclides migrating in the underground water, and resulting from one decay chain, is then proposed. As an example, the methodology is applied to a waste basin, built to receive effluents from a hypothectical uranium ore mining and milling facility. (M.A.C.) [pt

  10. Artificial radionuclide tracer supply to the Denmark strait overflow between 1972 and 1981

    International Nuclear Information System (INIS)

    Livingston, H.D.; Swift, J.H.; Ostlund, H.G.

    1985-01-01

    Measurements of the concentrations of the artificial radionuclides 3 H, 137 Cs, and 90 Sr in the northern Irminger Sea in 1972 and 1981 are reported. In both years, tracer measurements from this area included data from samples of the dense overflow water from the north through Denmark Strait. All three tracers were strongly correlated inversely with salinity in the dense outflows-the tracer maxima being related directly to the salinity minimum. When the tracer characteristics in the outflows in 1972 and 1981 were compared, concentrations of all in 1981 were observed to be about double the 1972 values. The individual tracer concentrations-on a decay-corrected, density-normalized basis-were higher in increasing order: 90 Sr(+93%) 3 H(+115%) 137 Cs(+150%). The relatively greater increases for 3 H and 137 Cs were attributed to contributions of new sources of these tracers in northern surface waters: the 3 H source is argued to derive from atmospheric hydrological recycling, whereas the 137 Cs source is identified as the input to the Greenland and Iceland seas of advected European nuclear fuel reprocessing wastes. Both the tracer and hydrographic data are used to identify northern locations of intermediate water formation capable of supplying the observed dense overflow water characteristics. It is argued, from the time taken for the overflow water to reflect the new surface 137 Cs source, that transport from the source to the overflow can be quite rapid (about 2 years)

  11. Regional modelling of tracer transport by tropical convection – Part 2: Sensitivity to model resolutions

    Directory of Open Access Journals (Sweden)

    J. Arteta

    2009-09-01

    Full Text Available The general objective of this series of two papers is to evaluate long duration limited-area simulations with idealised tracers as a possible tool to assess the tracer transport in chemistry-transport models (CTMs. In this second paper we analyse the results of three simulations using different horizontal and vertical resolutions. The goal is to study the impact of the model spatial resolution on convective transport of idealized tracer in the tropics. The reference simulation (REF uses a 60 km horizontal resolution and 300 m vertically in the upper troposphere/lower stratosphere (UTLS. A 20 km horizontal resolution simulation (HR is run as well as a simulation with 850 m vertical resolution in the UTLS (CVR. The simulations are run for one month during the SCOUT-O3 field campaign. Aircraft data, TRMM rainrate estimates and radiosoundings have been used to evaluate the simulations. They show that the HR configuration gives generally a better agreement with the measurements than the REF simulation. The CVR simulation gives generally the worst results. The vertical distribution of the tropospheric tracers for the simulations has a similar shape with a ~15 km altitude maximum for the 6h-lifetime tracer of 0.4 ppbv for REF, 1.2 for HR and 0.04 for CVR. These differences are related to the dynamics produced by the three simulations that leads to larger values of the upward velocities on average for HR and lower for CVR compared to REF. HR simulates more frequent and stronger convection leading to enhanced fluxes compared to REF and higher detrainment levels compared to CVR. HR provides also occasional overshoots over the cold point dynamical barrier. For the stratospheric tracers the differences between the three simulations are small. The diurnal cycle of the fluxes of all tracers in the Tropical Tropopause Layer exhibits a maximum linked to the maximum of convective activity.

  12. Slew-rate dependence of tracer magnetization response in magnetic particle imaging

    Science.gov (United States)

    Shah, Saqlain A.; Ferguson, R. M.; Krishnan, K. M.

    2014-10-01

    Magnetic Particle Imaging (MPI) is a new biomedical imaging technique that produces real-time, high-resolution tomographic images of superparamagnetic iron oxide nanoparticle tracers. Currently, 25 kHz and 20 mT/μ0 excitation fields are common in MPI, but lower field amplitudes may be necessary for patient safety in future designs. Here, we address fundamental questions about MPI tracer magnetization dynamics and predict tracer performance in future scanners that employ new combinations of excitation field amplitude (Ho) and frequency (ω). Using an optimized, monodisperse MPI tracer, we studied how several combinations of drive field frequencies and amplitudes affect the tracer's response, using Magnetic Particle Spectrometry and AC hysteresis, for drive field conditions at 15.5, 26, and 40.2 kHz, with field amplitudes ranging from 7 to 52 mT/μ0. For both fluid and immobilized nanoparticle samples, we determined that magnetic response was dominated by Néel reversal. Furthermore, we observed that the peak slew-rate (ωHo) determined the tracer magnetic response. Smaller amplitudes provided correspondingly smaller field of view, sometimes resulting in excitation of minor hysteresis loops. Changing the drive field conditions but keeping the peak slew-rate constant kept the tracer response almost the same. Higher peak slew-rates led to reduced maximum signal intensity and greater coercivity in the tracer response. Our experimental results were in reasonable agreement with Stoner-Wohlfarth model based theories.

  13. GTS-LCS, in-situ experiment 2. Modeling of tracer test 09-03

    International Nuclear Information System (INIS)

    Manette, M.; Saaltink, M.W.; Soler, J.M.

    2015-02-01

    Within the framework of the GTS-LCS project (Grimsel Test Site - Long-Term Cement Studies), an in-situ experiment lasting about 5 years was started in 2009 to study water-cement-rock interactions in a fractured granite. Prior to the experiment, a tracer test was performed to characterize the initial flow and transport properties of the rock around the experimental boreholes. This study reports on the model interpretation of tracer test 09-03. The calculations were performed by means of a two-dimensional model (homogeneous fracture plane including 3 boreholes) using the Retraso-CodeBright software package. In the tracer test, Grimsel groundwater containing the tracer (uranine) was circulated in the emplacement borehole during 43 days (zero injection flow rate). Circulation continued without tracer afterwards. Water was extracted at the observation and extraction boreholes. Results from a model sensitivity analysis comparing model results with measured tracer concentrations showed 3 cases where the evolution of tracer concentrations in the 3 different boreholes was satisfactory. In these cases a low-permeability skin affected the emplacement and observation boreholes. No skin appeared to affect the extraction borehole. The background hydraulic gradient seems to have no effect on the results of the tracer test. These results will be applied in the calculation of the initial flow field for the reactive transport phase of in-situ experiment 2 (interaction between pre-hardened cement and fractured granite at Grimsel). (orig.)

  14. Use of natural geochemical tracers to improve reservoir simulation models

    Energy Technology Data Exchange (ETDEWEB)

    Huseby, O.; Chatzichristos, C.; Sagen, J.; Muller, J.; Kleven, R.; Bennett, B.; Larter, S.; Stubos, A.K.; Adler, P.M.

    2005-01-01

    This article introduces a methodology for integrating geochemical data in reservoir simulations to improve hydrocarbon reservoir models. The method exploits routine measurements of naturally existing inorganic ion concentration in hydrocarbon reservoir production wells, and uses the ions as non-partitioning water tracers. The methodology is demonstrated on a North Sea field case, using the field's reservoir model, together with geochemical information (SO{sub 4}{sup 2}, Mg{sup 2+} K{sup +}, Ba{sup 2+}, Sr{sup 2+}, Ca{sup 2+}, Cl{sup -} concentrations) from the field's producers. From the data-set we show that some of the ions behave almost as ideal sea-water tracers, i.e. without sorption to the matrix, ion-exchange with the matrix or scale-formation with other ions in the formation water. Moreover, the dataset shows that ion concentrations in pure formation-water vary according to formation. This information can be used to allocate produced water to specific water-producing zones in commingled production. Based on an evaluation of the applicability of the available data, one inorganic component, SO{sub 4}{sup 2}, is used as a natural seawater tracer. Introducing SO{sub 4}{sup 2} as a natural tracer in a tracer simulation has revealed a potential for improvements of the reservoir model. By tracking the injected seawater it was possible to identify underestimated fault lengths in the reservoir model. The demonstration confirms that geochemical data are valuable additional information for reservoir characterization, and shows that integration of geochemical data into reservoir simulation procedures can improve reservoir simulation models. (author)

  15. Concentration of 232Th, 230Th and 228Th in various tissues of Japanese subjects

    International Nuclear Information System (INIS)

    Takizawa, Y.; Qingmei, H.; Hisamatsu, S.; Abe, T.

    1997-01-01

    The concentration of 232 Th, 230 Th and 228 Th in various human tissues of Japanese subjects obtained at autopsies are reported. The tissue samples were weighed, spiked with 234 Th tracer and ashed by acid. The solution was dried on a hot-plate. Separation of thorium radionuclides was accomplished through cation-exchange resin chromatography and electrodeposition. The concentrations of thorium isotopes were measured by α-spectrometry. Thorium-232 and 230 Th concentrations were found to be highest in lung, followed by bone. The maximum concentration of 228 Th was in bone. The lowest concentrations of thorium isotopes were in muscle. (author)

  16. ''Numerical simulation of passive tracer dispersion in the pacific ocean from Mururoa atoll (French Polynesia)''

    International Nuclear Information System (INIS)

    Rancher, J.; Lazar, A.; Maes, Ch.

    1996-12-01

    In order to evaluate, on a Tropical South Pacific scale over 10 years, the consequences of an hypothetic radionuclide releases to the ocean from French Nuclear test sites, a series of numerical simulations was carried out. Tracer advection and diffusion terms were computed by a dispersion model without taking into account radioactive decay and biological interactions. Ocean dynamics and turbulent mixing coefficients were derived from a Ocean General circulation Model using annual average climatological fields. A punctual release with unit activity concentration throughout the depth showed the existence of two major directions of propagation from Mururoa atoll: one toward the Eastern Pacific when releases originated from 100-150 meters or less, and the other Westward if release depth is greater. The maximum concentrations which may possibly reach the continental South Pacific coastline originated from released points located in the 350 meters depth zone. Another experiment showed that an punctual release yields higher concentrations than the continuous release of an equivalent quantity over 10 years; two punctual releases were carried out at the characteristic depth of 5 m and 364 m: maximum concentrations decrease by factors of 10 000 and 1000 over ten years. A comparison is made with the surface release study of Ribbe and Tomczak (1990), despite a significant discrepancy in propagation direction, the order of magnitude for concentrations is comparable. (author)

  17. Proceedings of Tracer 3. International Conference on Tracers and Tracing Methods

    International Nuclear Information System (INIS)

    2004-01-01

    Tracer 3 conference is a continuation of former Tracer 1 (1998) and Tracer 2 (2001) conferences organized by CNRS - Nancy France. The objective of this 3rd conference is presentation of different aspects of tracer method applications and development of tracer methodology.The new field of activity presented at the Conference was application of stable isotopes as natural tracers for investigations of environmental processes. The conference gave the possibility for scientific information exchange between specialists from different fields of activity such as chemical engineering, chemistry, bioengineering, environmental engineering, hydrology, civil engineering, metallurgy, etc. The presentations were divided into groups covering the principal items of Conference. Section A. Fundamental development - RTD and tracer methodology, - RTD methodology and Computational Fluid Dynamics (CFD), - New tracers and detectors. Section B. Industrial applications - Environment, - Geology, hydrogeology and oil field applications, - Civil engineering, mineral engineering and metallurgy applications, - Food engineering and bioengineering, - Material engineering, - Chemical engineering. During the Conference INIS promotion materials were exposed by INIS liaison officer for Poland

  18. Proceedings of Tracer 3. International Conference on Tracers and Tracing Methods

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    Tracer 3 conference is a continuation of former Tracer 1 (1998) and Tracer 2 (2001) conferences organized by CNRS - Nancy France. The objective of this 3rd conference is presentation of different aspects of tracer method applications and development of tracer methodology.The new field of activity presented at the Conference was application of stable isotopes as natural tracers for investigations of environmental processes. The conference gave the possibility for scientific information exchange between specialists from different fields of activity such as chemical engineering, chemistry, bioengineering, environmental engineering, hydrology, civil engineering, metallurgy, etc. The presentations were divided into groups covering the principal items of Conference. Section A. Fundamental development - RTD and tracer methodology, - RTD methodology and Computational Fluid Dynamics (CFD), - New tracers and detectors. Section B. Industrial applications - Environment, - Geology, hydrogeology and oil field applications, - Civil engineering, mineral engineering and metallurgy applications, - Food engineering and bioengineering, - Material engineering, - Chemical engineering. During the Conference INIS promotion materials were exposed by INIS liaison officer for Poland.

  19. Deuterium used as artificial tracer in column studies under saturated water flow conditions

    Science.gov (United States)

    Koeniger, P.; Geiges, M.; Leibundgut, Ch.

    2003-04-01

    In contrast to numerous investigations using deuterium as an environmental tracer, hydrological investigations with deuterium-labelled water are rather rare. Currently applications in groundwater studies are restricted due to increasing costs of spiking large water quantities but an application as intelligent tracer might be of advantage especially in combination with other tracers and under distinct environmental conditions. Therefore deuterium was applied as artificial tracer in column experiments that are well proved as a tool to characterise tracer behaviour in recent studies. Deuterium was tested in comparison to the more familiar conservative tracer fluorescein. Varying experimental conditions, e.g. column length (0.5, 1.0, 1.5 m), initial tracer concentration (0.01, 0.02, 0.2 mg) and flow velocity (1.5 to 6.0 m/d) were used to investigate tracer behaviour under saturated water flow conditions. Deuterium was analysed using an H/Device with chrome reduction connected to an isotope ratio mass spectrometer and expressed in relative concentrations [per mill V-SMOW]. Theoretical tracer breakthrough curves were calculated using a one dimensional dispersion model. The results indicate higher mean transport velocities and smaller dispersion for deuterium in all experiments. Due to different molecule properties that also determine the interaction of soil substrate and tracer, deuterium indicates a more conservative transport behaviour. Deuterium is non-toxic, completely soluble, chemically and biologically stable and not subject to light-influenced decay. Furthermore, it shows promise for investigations of water flow in the unsaturated zone, and of interactions of water in soil-plant-atmosphere systems. A further discussion of problems, together with possibilities for applying deuterium as an artificial tracer, will be presented.

  20. Tracer theory

    International Nuclear Information System (INIS)

    Margrita, R.

    1988-09-01

    Tracers are used in many fields of science to investigate mass transfer. The scope of tracers applications in Service of Applications Radioisotopes (S.A.R.-France) is large and concerns natural and industrial systems such as Sciences of earth: hydrology - civil engineering - Sedimentology - environmental studies. Industrial field: chemical engineering - mechanical engineering. A general tracer methodology has been developed in our laboratories from these different applications fields and this paper shows these different points of view in using tracers; our wish is that the methods used in an experimental field can be employed in an another one

  1. Test determination with tritium as a radioactive tracer of the residence time distribution in the stability pool for Cabrero sewage

    International Nuclear Information System (INIS)

    Diaz, Francisco; Duran, Oscar; Henriquez, Pedro; Vega, Pedro; Padilla, Liliana; Gonzalez, David; Garcia Agudo, Edmundo

    2000-01-01

    This work was prepared by the Chilean and International Atomic Energy Agencies and covers the hydrodynamic functioning of sewage stability pools using tracers. The plant selected in the city of Cabrero, 500 km. south of Santiago, and is a rectangular facultative pool with a surface area of 7100 m 2 and a maximum volume of 12,327 m2 that receives an average flow of 20 l/s, serving a population of 7000 individuals. The work aims to characterize the runoff from the flow that enters the pool, using a radioactive tracer test, where the incoming water is marked, and its out-coming passage is determined, to establish the residence time distribution. Tritium was selected in the form of tritiated water as a tracer that is precisely emptied into the water flow from the distribution ravine at the lake entrance. Samples are taken at the outflow to determine the concentration of tritium after distillation, simultaneously measuring the flow, to be analyzed in a liquid flicker counter. An average test time of 5.3 days was obtained and an analysis of the residence time distribution for the tracer shows that it leaves quickly and indicates bad flow distribution in the lake with a major short circuit and probable dead zones

  2. Contamination tracer testing with seabed drills: IODP Expedition 357

    Science.gov (United States)

    Orcutt, Beth N.; Bergenthal, Markus; Freudenthal, Tim; Smith, David; Lilley, Marvin D.; Schnieders, Luzie; Green, Sophie; Früh-Green, Gretchen L.

    2017-11-01

    IODP Expedition 357 utilized seabed drills for the first time in the history of the ocean drilling program, with the aim of collecting intact sequences of shallow mantle core from the Atlantis Massif to examine serpentinization processes and the deep biosphere. This novel drilling approach required the development of a new remote seafloor system for delivering synthetic tracers during drilling to assess for possible sample contamination. Here, we describe this new tracer delivery system, assess the performance of the system during the expedition, provide an overview of the quality of the core samples collected for deep biosphere investigations based on tracer concentrations, and make recommendations for future applications of the system.

  3. Maximum permissible concentration (MPC) values for spontaneously fissioning radionuclides

    International Nuclear Information System (INIS)

    Ford, M.R.; Snyder, W.S.; Dillman, L.T.; Watson, S.B.

    1976-01-01

    The radiation hazards involved in handling certain of the transuranic nuclides that exhibit spontaneous fission as a mode of decay were reaccessed using recent advances in dosimetry and metabolic modeling. Maximum permissible concentration (MPC) values in air and water for occupational exposure (168 hr/week) were calculated for 244 Pu, 246 Cm, 248 Cm, 250 Cf, 252 Cf, 254 Cf, /sup 254m/Es, 255 Es, 254 Fm, and 256 Fm. The half-lives, branching ratios, and principal modes of decay of the parent-daughter members down to a member that makes a negligible contribution to the dose are given, and all daughters that make a significant contribution to the dose to body organs following inhalation or ingestion are included in the calculations. Dose commitments for body organs are also given

  4. Artificial radionuclide tracer supply to the Denmark Strait overflow between 1972 and 1981

    Science.gov (United States)

    Livingston, Hugh D.; Swift, James H.; Ostlund, H. Gote

    1985-01-01

    Measurements of the concentrations of the artificial radionuclides 3H, 137Cs, and 90Sr in the northern Irminger Sea in 1972 and 1981 are reported. In both years, tracer measurements from this area included data from samples of the dense overflow water from the north through Denmark Strait. All three tracers were strongly correlated inversely with salinity in the dense outflows—the tracer maxima being related directly to the salinity minimum. When the tracer characteristics in the outflows in 1972 and 1981 were compared, concentrations of all in 1981 were observed to be about double the 1972 values. The individual tracer concentrations—on a decay-corrected, density-normalized basis—were higher in increasing order: 90Sr (+93%) seas of advected European nuclear fuel reprocessing wastes. Both the tracer and hydrographic data are used to identify northern locations of intermediate water formation capable of supplying the observed dense overflow water characteristics. It is argued, from the time taken for the overflow water to reflect the new surface 137Cs source, that transport from the source to the overflow can be quite rapid (about 2 years).

  5. Diffusing passive tracers in random incompressible flows: Statistical topography aspects

    International Nuclear Information System (INIS)

    Klyatskin, V.I.; Woyczynski, W.A.; Gurarie, D.

    1996-01-01

    The paper studies statistical characteristics of the passive tracer concentrations and of its spatial gradient, in random incompressible velocity fields from the viewpoint of statistical topography. The statistics of interest include mean values, probability distributions, as well as various functionals characterizing topographic features of tracers. The functional approach is used. We consider the influence of the mean flow (the linear shear flow) and the molecular diffusion coefficient on the statistics of the tracer. Most of our analysis is carried out in the framework of the delta-correlated (in time) approximation and conditions for its applicability are established. But we also consider the diffusion approximation scheme for finite correlation radius. The latter is applied to a diffusing passive tracer that undergoes sedimentation in a random velocity field

  6. Radionuclides as tracers

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Importance of radioisotopes in medicine is because of their two characteristics: their biological behaviour is identical to their stable counterparts, and because they are radioactive their emissions can be detected by a suitable instrument. All isotopes of iodine will behave in the same way and will concentrate in the thyroid gland. There is no way of detecting the stable, natural iodine in the thyroid gland, but the presence of radioactive iodine can be detected externally in vivo by a detector. Thus, the radioactive iodine becomes a tracer, a sport of a spy, which mimics the behaviour of natural iodine and relays information to a detector. The radioactive tracers are popular because of the ease with which they can be detected in vivo and the fact that the measurement of their presence in the body can be in quantitative terms. The measurement can be very accurate and sensitive. Whenever the measurements can be done in vivo, the information is obtained in dynamic terms, as it is happening, as if the physiological events become transparent

  7. Contamination tracer testing with seabed drills: IODP Expedition 357

    Directory of Open Access Journals (Sweden)

    B. N. Orcutt

    2017-11-01

    Full Text Available IODP Expedition 357 utilized seabed drills for the first time in the history of the ocean drilling program, with the aim of collecting intact sequences of shallow mantle core from the Atlantis Massif to examine serpentinization processes and the deep biosphere. This novel drilling approach required the development of a new remote seafloor system for delivering synthetic tracers during drilling to assess for possible sample contamination. Here, we describe this new tracer delivery system, assess the performance of the system during the expedition, provide an overview of the quality of the core samples collected for deep biosphere investigations based on tracer concentrations, and make recommendations for future applications of the system.

  8. Radioactive tracer technique in process optimization: applications in the chemical industry

    International Nuclear Information System (INIS)

    Charlton, J.S.

    1989-01-01

    Process optimization is concerned with the selection of the most appropriate technological design of the process and with controlling its operation to obtain maximum benefit. The role of radioactive tracers in process optimization is discussed and the various circumstances under which such techniques may be beneficially applied are identified. Case studies are presented which illustrate how radioisotopes may be used to monitor plant performance under dynamic conditions to improve production efficiency and to investigate the cause of production limitations. In addition, the use of sealed sources to provide information complementary to the tracer study is described. (author)

  9. Use of tracers for locating and designing sea outfalls

    International Nuclear Information System (INIS)

    Gauthier, M.; Quetin, B.

    1976-01-01

    Various tracers are used for investigating the propagation of substances in solution or suspension (radioactive, biological, chemical substances and floats). Floats and dyes are the most employed. The main problems associated with the use of such tracers and data interpretation are discussed and it is shown how effective quantitative data can be obtained, especially as regards estimation of turbulent diffusion parameters and identification of suitable dispersion methods for purposes of determining pollutant concentration and areas affected thereby [fr

  10. Laplace transform in tracer kinetic modeling

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, Eliete B., E-mail: eliete@pucrs.br [Instituto do Cerebro (InsCer/FAMAT/PUC-RS), Porto Alegre, RS, (Brazil). Faculdade de Matematica

    2013-07-01

    The main objective this paper is to quantify the pharmacokinetic processes: absorption, distribution and elimination of radiopharmaceutical(tracer), using Laplace transform method. When the drug is administered intravenously absorption is complete and is available in the bloodstream to be distributed throughout the whole body in all tissues and fluids, and to be eliminated. Mathematical modeling seeks to describe the processes of distribution and elimination through compartments, where distinct pools of tracer (spatial location or chemical state) are assigned to different compartments. A compartment model is described by a system of differential equations, where each equation represents the sum of all the transfer rates to and from a specific compartment. In this work a two-tissue irreversible compartment model is used for description of tracer, [{sup 18}F]2-fluor-2deoxy-D-glucose. In order to determine the parameters of the model, it is necessary to have information about the tracer delivery in the form of an input function representing the time-course of tracer concentration in arterial blood or plasma. We estimate the arterial input function in two stages and apply the Levenberg-Marquardt Method to solve nonlinear regressions. The transport of FDG across de arterial blood is very fast in the first ten minutes and then decreases slowly. We use de Heaviside function to represent this situation and this is the main contribution of this study. We apply the Laplace transform and the analytical solution for two-tissue irreversible compartment model is obtained. The only approach is to determinate de arterial input function. (author)

  11. Feasibility of a tracer gas technique for containment leakage characterization at Bruce NGS

    International Nuclear Information System (INIS)

    Singh, V.P.

    1985-11-01

    Methods for tracer gas test have been conceived and are proposed for use in conjunction with other techniques used during off-power pressurization tests. During pressurization tests is appears possible to quantify leaks through containment boundaries which make up one of the walls in adjacent rooms but quantification of leaks to open areas will require further development. Several gases may be used as tracers during pressurization tests but the preferred tracer gas is sulphur hexafluoride (SF 6 ) at an in-vault concentration of 100 μL/L if open area sampling is to be carried out of 10 μL/L if only closed room sampling is to be performed. Large values of the ratio (tracer gas concentration in containment/lower detection limit) are necessary for identification of leak sites in open areas having significant ventilation flow. It is recommended that in-station trials be carried out to test the validity of this technique. In addition, a tracer gas technique for use during on-power operation is also proposed but leak site identification and quantification during on-power tests is only possible for containment boundaries which make up the wall(s) of adjacent rooms. The use of SF 6 is required for tests conducted during on-power operation. The recommended in-vault concentration is 10 μL/L. Recommendations are made for future work, including leak tests during on-power operation

  12. Effect on tracer concentrations of ABL depth models in complex terrain

    Energy Technology Data Exchange (ETDEWEB)

    Galmarini, S.; Salin, P. [Joint Research Center Ispra (Italy); Anfossi, D.; Trini-Castelli, S. [CNR-ICGF, Turin (Italy); Schayes, G. [Univ. Louvain-la-Neuve, Louvain (Belgium)

    1997-10-01

    In the present preliminary study we use different ABL (atmospheric boundary layer) depth formulations to study atmospheric dispersion in complex-terrain conditions. The flow in an Alpine valley during the tracer experiment TRANSALP is simulated by means of a mesoscale model and a tracer dispersion is reproduced using a Lagrangian particle model. The ABL dept enters as key parameter in particle model turbulent-dispersion formulation. The preliminary results reveal that the ABL depth parameter can influence the dispersion process but that in the case of a dispersion in a valley-daytime flow the results depend much more strongly on the model horizontal and vertical resolution. A relatively coarse horizontal resolution implies a considerable smoothing of the topography that largely affects the dispersion characteristics. The vertical resolution does not allow on to resolve with sufficient details the rapid and large variation of the flow characteristic as the terrain feature vary. Two of the methods used to determine the ABL depth depend strongly on the resolution. The method that instead depends only on surface parameters like heat flux and surface based stability allowed us to obtain results to be considered satisfactory for what concerns the dispersion process, quite consistent with the flow model results, less numeric dependent and more physically sound. (LN)

  13. Radon diagnostics and tracer gas measurements

    International Nuclear Information System (INIS)

    Jilek, K.; Brabec, M.

    2004-01-01

    An outline is presented of the tracer gas technique, which is used for continuous measurements of air ventilation rate (generally time-varying) and for simultaneous estimation of air ventilation rate and radon entry rate, and some of its limitations are discussed. The performance of this technique in the calculation of the air ventilation rate is demonstrated on real data from routine measurements. The potential for air ventilation rate estimation based on radon measurements only is discussed. A practical application is described of the tracer gas technique to a simultaneous estimation of the air ventilation rate and radon entry rate in a real house where the effectiveness of radon remedy was tested. The following main advantages of the CO tracer gas techniques are stressed: (i) The averaging method continuous determination of the ventilation rate with good accuracy (≤ 20 %). (ii) The newly presented and verified method based on simultaneous measurements of radon concentration and CO gas concentration enables separate continuous measurements of the radon entry rate and ventilation rate. The results of comparative measurements performed with the aim to estimate the inaccuracy in determination of radon entry rate showed acceptable and good agreement up to approximately 10 %. The results of comparative measurements performed with the aim to estimate the mutual commensuration of the method to the determination of the ventilation rate confirmed the expected unreliability the two parametric non-linear regression method, which is the most frequently used method in radon diagnostic in the Czech Republic

  14. Contamination Tracer Testing With Seabed Rock Drills: IODP Expedition 357

    Science.gov (United States)

    Orcutt, B.; Bergenthal, M.; Freudenthal, T.; Smith, D. J.; Lilley, M. D.; Schneiders, L.; Fruh-Green, G. L.

    2016-12-01

    IODP Expedition 357 utilized seabed rock drills for the first time in the history of the ocean drilling program, with the aim of collecting intact core of shallow mantle sequences from the Atlantis Massif to examine serpentinization processes and the deep biosphere. This new drilling approach required the development of a new system for delivering synthetic tracers during drilling to assess for possible sample contamination. Here, we describe this new tracer delivery system, assess the performance of the system during the expedition, provide an overview of the quality of the core samples collected for deep biosphere investigations based on tracer concentrations, and make recommendations for future applications of the system.

  15. Improvement of the qualitative and quantitative detection of simultaneously present fluorescent tracers by systematic sample treatment

    International Nuclear Information System (INIS)

    Behrens, H.

    1982-01-01

    The selective instrumental detection of individual fluorescent tracers in mixtures containing further fluorescent dyes is limited by spectral interferences. Therefore additional separations or other suitable procedures have to be included into the analytic technique. With the method described below, the respective tracer to be detected remains with its initial concentration in the sample and is analysed under the appropriate conditions, whereas the interfering tracers are separated or suppressed. The techniques applied for this base on the facts that 1) the fluorescence intensity of the tracers varies differently when the pH-value changes; 2) the tracers show different absorption behaviour and 3) they provide different degrees of light sensitivity. The procedures permit for example to detect uranin when eosin is present in a higher concentration or to detect eosin when amidorhodamin G is present. (orig.) [de

  16. The maximum ground level concentration of air pollutant and the effect of plume rise on concentration estimates

    International Nuclear Information System (INIS)

    Mayhoub, A.B.; Azzam, A.

    1991-01-01

    The emission of an air pollutant from an elevated point source according to Gaussian plume model has been presented. An elementary theoretical treatment for both the highest possible ground-level concentration and the downwind distance at which this maximum occurs for different stability classes has been constructed. The effective height release modification was taken into consideration. An illustrative case study, namely, the emission from the research reactor in Inchas, has been studied. The results of these analytical treatments and of the derived semi-empirical formulae are discussed and presented in few illustrative diagrams

  17. Estimating the Spatial Distribution of Groundwater Age Using Synoptic Surveys of Environmental Tracers in Streams

    Science.gov (United States)

    Gardner, W. P.

    2017-12-01

    A model which simulates tracer concentration in surface water as a function the age distribution of groundwater discharge is used to characterize groundwater flow systems at a variety of spatial scales. We develop the theory behind the model and demonstrate its application in several groundwater systems of local to regional scale. A 1-D stream transport model, which includes: advection, dispersion, gas exchange, first-order decay and groundwater inflow is coupled a lumped parameter model that calculates the concentration of environmental tracers in discharging groundwater as a function of the groundwater residence time distribution. The lumped parameters, which describe the residence time distribution, are allowed to vary spatially, and multiple environmental tracers can be simulated. This model allows us to calculate the longitudinal profile of tracer concentration in streams as a function of the spatially variable groundwater age distribution. By fitting model results to observations of stream chemistry and discharge, we can then estimate the spatial distribution of groundwater age. The volume of groundwater discharge to streams can be estimated using a subset of environmental tracers, applied tracers, synoptic stream gauging or other methods, and the age of groundwater then estimated using the previously calculated groundwater discharge and observed environmental tracer concentrations. Synoptic surveys of SF6, CFC's, 3H and 222Rn, along with measured stream discharge are used to estimate the groundwater inflow distribution and mean age for regional scale surveys of the Berland River in west-central Alberta. We find that groundwater entering the Berland has observable age, and that the age estimated using our stream survey is of similar order to limited samples from groundwater wells in the region. Our results show that the stream can be used as an easily accessible location to constrain the regional scale spatial distribution of groundwater age.

  18. Optimization of copper ore concentration processing by means of radioactive tracers

    International Nuclear Information System (INIS)

    Petryka, L.; Przewlocki, K.

    1989-01-01

    Flotation of polymetallic ores in the Polish Lower Silesian Basin was taken as an example for the optimization of copper ore processing using radioactive tracers. An original stochastic mathematical model (stream model) was proposed to minimize copper losses in tailing. A detailed procedure of measurement is presented as well as the experimental data and their interpretation. On the basis of this research copper losses in tailing can be reduced to one third. (author)

  19. Tracer Testing for Estimating Heat Transfer Area in Fractured Reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Pruess, Karsten; van Heel, Ton; Shan, Chao

    2004-05-12

    A key parameter governing the performance and life-time of a Hot Fractured Rock (HFR) reservoir is the effective heat transfer area between the fracture network and the matrix rock. We report on numerical modeling studies into the feasibility of using tracer tests for estimating heat transfer area. More specifically, we discuss simulation results of a new HFR characterization method which uses surface-sorbing tracers for which the adsorbed tracer mass is proportional to the fracture surface area per unit volume. Sorption in the rock matrix is treated with the conventional formulation in which tracer adsorption is volume-based. A slug of solute tracer migrating along a fracture is subject to diffusion across the fracture walls into the adjacent rock matrix. Such diffusion removes some of the tracer from the fluid in the fractures, reducing and retarding the peak in the breakthrough curve (BTC) of the tracer. After the slug has passed the concentration gradient reverses, causing back-diffusion from the rock matrix into the fracture, and giving rise to a long tail in the BTC of the solute. These effects become stronger for larger fracture-matrix interface area, potentially providing a means for estimating this area. Previous field tests and modeling studies have demonstrated characteristic tailing in BTCs for volatile tracers in vapor-dominated reservoirs. Simulated BTCs for solute tracers in single-phase liquid systems show much weaker tails, as would be expected because diffusivities are much smaller in the aqueous than in the gas phase, by a factor of order 1000. A much stronger signal of fracture-matrix interaction can be obtained when sorbing tracers are used. We have performed simulation studies of surface-sorbing tracers by implementing a model in which the adsorbed tracer mass is assumed proportional to the fracture-matrix surface area per unit volume. The results show that sorbing tracers generate stronger tails in BTCs, corresponding to an effective

  20. A comparison of measurements and calculations for the Stripa tracer experiments

    International Nuclear Information System (INIS)

    Hodgkinson, D.P.; Copper, N.S.

    1992-03-01

    This paper presents a comparison of measurements and predictions for migration of tracers from boreholes to the validation drift and to other boreholes in the Site Characterisation and Validation (SCV) block. The comparison was carried out on behalf of the Stripa task force on fracture flow modelling. The paper summarises the radar/saline tracer experiments, the tracer migration experiment observations and reviews the fracture flow and tracer transport modelling approaches and predictions made by AEA Technology, Fracflow Consultants, Golder Associates and Lawrence Berkeley Laboratory. The predictions are compared with the observed breakthrough curves on the basis of the validation process and criteria defined by the task force. The results of all four modelling groups met the validation criteria, with the predictions of the tracer breakthrough concentrations and times being within an order of magnitude of the observations. Also the AEA and Golder approaches allow the spatial distribution of tracer breakthrough into the validation drift to be predicted and these predictions also showed reasonable accuracy. The successful completion of this project demonstrates the feasibility of discrete fracture flow and tracer transport modelling. (36 refs.) (au)

  1. Tracer measured substrate turnover requires arterial sampling downstream of infusion site

    International Nuclear Information System (INIS)

    Stanley, W.C.; Neese, R.A.; Gertz, E.W.; Wisneski, J.A.; Morris, D.L.; Brooks, G.A.

    1986-01-01

    Measurement of metabolite turnover (Rt) with radioactive tracers is done by either infusing tracer venously and sampling specific activity (SA) arterially (V-A modes), or by infusing into the aorta and sampling venous blood (A-V mode). Using the Fick principle, the necessity for using the V-A mode can be demonstrated. If tracer is infused into the left ventricle, in a steady state the Rt is the product of arterial trace concentration, the cardiac output, and the tracer extraction ratio for the whole body. This is expressed as: Rt = Ca x Qx ((*Ca - *Cv)/*Ca) (Eq1) where C=trace concentration (μmol/ml), *C=tracer conc. (dpm/ml), a=arterial, v-=mixed venous, and Q=cardiac output (ml/min). Rearranging the equation: Rt = Qx(*Ca - *Cv)/SAa = F/SAa (Eq2) where SAa is *Ca/Ca, and Qx (*Ca-*Cv) equals the infusion rate (F). The authors compared Eqs1 and 2 (Rt = F/SAa) in 3 anesthetized dogs in which [1- 14 C] lactate was infused into the left ventricle, and blood was sampled arterially downstream from the infusion site and in the pulmonary artery. Eqs 1 and 2 gave similar results for Rt (45.9 vs. 43.9 μmol/kg min), while substituting SAv for SAa (A-V mode) into Eq 2 gave a higher Rt (53.6). When SAv (A-V mode) is used, the specific activity seen by the tissues (SAa) is not considered in the calculation of Rt. Therefore, only the V-A mode meets the requirements for tracer measured metabolite turnover

  2. Determining concentration fields of tracer plumes for layered porous media in flow-tank experiments

    Science.gov (United States)

    Yu, Zhongbo; Schwartz, Franklin W.

    In the laboratory, computer-assisted image analysis provides an accurate and efficient way to monitor tracer experiments. This paper describes the determination of detailed temporal concentration distributions of tracers in a flow-tank experiment by analyzing photographs of plumes of Rhodamine dye through the glass wall of the tank. The methodology developed for this purpose consists of four steps: (1) digitally scanning black and white negatives obtained from photographs of the flow-tank experiment; (2) calibrating and normalizing each digitized image to a standard optical-density scale by determining the relation between the optical density and pixel value for each image; (3) constructing standard curves relating the concentration in an optical density from five experimental runs with predetermined concentrations (2-97mg/L) and (4) converting the optical density to concentration. The spatial distribution of concentration for two photographs was determined by applying these calibration and conversion procedures to all pixels of the digitized images. This approach provides an efficient way to study patterns of plume evolution and transport mechanisms. Résumé Au laboratoire, l'analyse d'images assistée par ordinateur est un moyen précis et efficace pour suivre certaines expériences de traçage. Ce papier présente comment sont déterminées dans le détail les distributions temporelles de la concentration en traceur au cours d'une expérience d'écoulement en réservoir au moyen de l'analyse de photographies de panaches de rhodamine à travers la paroi de verre du réservoir. La méthodologie développée dans cette expérience suit quatre étapes: (1) digitalisation par balayage des négatifs noir et blanc des prises de vue de l'expérience d'écoulement en réservoir (2) calibration et normalisation de chaque image digitalisée par rapport à une échelle étalon de densité optique en déterminant la relation entre la densité optique et la valeur des pixels

  3. Radon as geological tracer

    Energy Technology Data Exchange (ETDEWEB)

    Lacerda, T.; Anjos, R.M. [Universidade Federal Fluminense (UFF), Niteroi, RJ (Brazil). Inst. de Fisica; Valladares, D.L.; Rizzotto, M.; Velasco, H.; Ayub, J. Juri [Universidad Nacional de San Luis (Argentina). Inst. de Matematica Aplicada San Luis (IMASL); Silva, A.A.R. da; Yoshimura, E.M. [Universidade de Sao Paulo (IF/USP), SP (Brazil). Inst. de Fisica

    2012-07-01

    Full text: This work presents measurements of {sup 222}Rn levels performed in La Carolina gold mine and Los Condores tungsten mine at the province of San Luis, Argentina, today used for tourist visitation, and can evaluate the potential use of such radioactive noble gas as tracer or marker for geological processes in underground environments. By concentrations of {sup 40}K, {sup 232}Th and {sup 23}'8U were also measured in the walls of tunnels were determined the rocks mineral composition, what indicated that the mines have the same composition. In this sense, we used nuclear trace plastic detectors CR-39, gamma spectrometry of rock samples and Geiger-Muller (GM) monitors The patterns of radon gas transportation processes revealed that La Carolina could be interpreted through a model based on a radioactive gas confined into a single entrance tube, with constant cross section and air velocity. Los Condores, which has a second main entrance, could be interpreted through a model based on a radioactive gas confined into a two entrance tube, allowing a chimney effect for air circulation. The results showed the high potential of using {sup 222}Rn as a geological tracer. In what concerns the occupational hazard, in summer (time of more intense tourist activity in the mine) La Carolina presented a mean concentration of the radioactive noble gas that exceeds in four times the action level of 1,5 kBq m{sup -3} recommended by the International Commission of Radiological Protection (ICRP). The chimney effect shows the low mean concentration of radon in Los Condores. (author)

  4. Radon as geological tracer

    International Nuclear Information System (INIS)

    Lacerda, T.; Anjos, R.M.; Silva, A.A.R. da; Yoshimura, E.M.

    2012-01-01

    Full text: This work presents measurements of 222 Rn levels performed in La Carolina gold mine and Los Condores tungsten mine at the province of San Luis, Argentina, today used for tourist visitation, and can evaluate the potential use of such radioactive noble gas as tracer or marker for geological processes in underground environments. By concentrations of 40 K, 232 Th and 23 '8U were also measured in the walls of tunnels were determined the rocks mineral composition, what indicated that the mines have the same composition. In this sense, we used nuclear trace plastic detectors CR-39, gamma spectrometry of rock samples and Geiger-Muller (GM) monitors The patterns of radon gas transportation processes revealed that La Carolina could be interpreted through a model based on a radioactive gas confined into a single entrance tube, with constant cross section and air velocity. Los Condores, which has a second main entrance, could be interpreted through a model based on a radioactive gas confined into a two entrance tube, allowing a chimney effect for air circulation. The results showed the high potential of using 222 Rn as a geological tracer. In what concerns the occupational hazard, in summer (time of more intense tourist activity in the mine) La Carolina presented a mean concentration of the radioactive noble gas that exceeds in four times the action level of 1,5 kBq m -3 recommended by the International Commission of Radiological Protection (ICRP). The chimney effect shows the low mean concentration of radon in Los Condores. (author)

  5. Rate tracer studies of heterogeneous catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Happel, J; Kiang, S

    1977-10-01

    An analysis is presented of the extent to which parameters involved in transient tracing of isotopic species in heterogeneous catalysis can be determined by experiments in which tracer concentrations are measured as a function of time. Different treatments for open and closed systems with the over-all reaction at equilibrium or irreversible were developed.

  6. Exploring Hydrofluorocarbons as Groundwater Age Tracers (Invited)

    Science.gov (United States)

    Haase, K. B.; Busenberg, E.; Plummer, L. N.; Casile, G.; Sanford, W. E.

    2013-12-01

    Groundwater dating tracers are an essential tool for analyzing hydrologic conditions in groundwater systems. Commonly used tracers for dating post-1940's groundwater include sulfur hexafluoride (SF6), chlorofluorocarbons (CFCs), 3H-3He, and other isotopic tracers (85Kr, δ2H and δ18O isotopes, etc.). Each tracer carries a corresponding set of advantages and limitations imposed by field, analytical, and interpretive methods. Increasing the number available tracers is appealing, particularly if they possess inert chemical properties and unique temporal emission histories from other tracers. Atmospherically derived halogenated trace gases continue to hold untapped potential for new tracers, as they are generally inert and their emission histories are well documented. SF5CF3, and CFC-13 were previously shown to have application as dating tracers, though their low mixing ratios and low solubility require large amounts of water to be degassed for their quantification. Two related groups of compounds, hydrochlorofluorocarbons (HCFCs) and hydrofluorocarbons (HFCs) are hypothesized to be potential age tracers, having similar mixing ratios to the CFCs and relatively high solubility. However, these compounds yield gas chromatography electron capture detector (GC-ECD) responses that are 10-2 -10-5 less than CFC-12, making purge and trap or field stripping GC-ECD approaches impractical. Therefore, in order to use dissolved HCFCs and HFCs as age tracers, different approaches are needed. To solve this problem, we developed an analytical method that uses an atomic emission detector (GC-AED) in place of an ECD to detect fluorinated compounds. In contrast to the ECD, the AED is a universally sensitive, highly linear, elementally specific detector. The new GC-AED system is being used to measure chlorodifluoromethane (HCFC-22), 1,1,1,2-tetrafluoroethane (HFC-134a), and other fluorinated compounds in one liter water samples to study their potential as age dating tracers. HCFC-22 is a

  7. Delayed appearance of tracer lead in facial hair

    International Nuclear Information System (INIS)

    Rabinowitz, M.; Wetherill, G.; Kopple, J.

    1976-01-01

    Three adult men were fed 204 Pb--a rare, stable isotope of lead--daily for about 100 days. Simultaneous blood and facial hair measurements of this tracer and of total lead concentrations were made by mass spectrometric isotope dilution analysis. Although the blood showed an immediate response to the intake of the tracer, the facial hair showed a more gradual response and a delay of approximately 35 days. Since the pattern of appearance of lead in hair does not appear to represent a simple time delay of blood lead concentration, the existence of a physiological pool of lead fed by the blood and giving rise to the content in hair is suggested. Hair lead values should therefore, be interpreted as the integral of the blood lead values over the mean life of this intermediate pool--about 100 days

  8. Long residence times - bad tracer tests?

    Science.gov (United States)

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2015-04-01

    Tracer tests conducted at geothermal well doublets or triplets in the Upper Rhine Rift Valley [1] all face, with very few exceptions so far, one common issue: lack of conclusive tracer test results, or tracer signals still undetectable for longer than one or two years after tracer injection. While the reasons for this surely differ from site to site (Riehen, Landau, Insheim, Bruchsal, ...), its effects on how the usefulness of tracer tests is perceived by the non-tracer community are pretty much the same. The 'poor-signal' frustration keeps nourishing two major 'alternative' endeavours : (I) design and execute tracer tests in single-well injection-withdrawal (push-pull), 'instead of' inter-well flow-path tracing configurations; (II) use 'novel' tracer substances instead of the 'old' ones which have 'obviously failed'. Frustration experienced with most inter-well tracer tests in the Upper Rhine Rift Valley has also made them be regarded as 'maybe useful for EGS' ('enhanced', or 'engineered' geothermal systems, whose fluid RTD typically include a major share of values below one year), but 'no longer worthwhile a follow-up sampling' in natural, large-scale hydrothermal reservoirs. We illustrate some of these arguments with the ongoing Bruchsal case [2]. The inter-well tracer test conducted at Bruchsal was (and still is!) aimed at assessing inter-well connectivity, fluid residence times, and characterizing the reservoir structure [3]. Fluid samples taken at the geothermal production well after reaching a fluid turnover of about 700,000 m3 showed tracer concentrations in the range of 10-8 Minj per m3, in the liquid phase of each sample (Minj being the total quantity of tracer injected as a short pulse at the geothermal re-injection well). Tracer signals might actually be higher, owing to tracer amounts co-precipitated and/or adsorbed onto the solid phase whose accumulation in the samples was unavoidable (due to pressure relief and degassing during the very sampling

  9. Relative Roles of Gap Junction Channels and Cytoplasm in Cell-to-Cell Diffusion of Fluorescent Tracers

    Science.gov (United States)

    Safranyos, Richard G. A.; Caveney, Stanley; Miller, James G.; Petersen, Nils O.

    1987-04-01

    Intercellular (tissue) diffusion of molecules requires cytoplasmic diffusion and diffusion through gap junctional (or cell-to-cell) channels. The rates of tissue and cytoplasmic diffusion of fluorescent tracers, expressed as an effective diffusion coefficient, De, and a cytoplasmic diffusion coefficient, Dcyt, have been measured among the developing epidermal cells of a larval beetle, Tenebrio molitor L., to determine the contribution of the junctional channels to intercellular diffusion. Tracer diffusion was measured by injecting fluorescent tracers into cells and quantitating the rate of subsequent spread into adjacent cells. Cytoplasmic diffusion was determined by fluorescence photobleaching. These experiments show that gap junctional channels constitute approximately 70-80% of the total cell-to-cell resistance to the diffusion of organic tracers at high concentrations in this tissue. At low concentrations, however, the binding of tracer to cytoplasm slows down the cytoplasmic diffusion, which may limit intercellular diffusion.

  10. Characterization of a managed aquifer recharge system using multiple tracers.

    Science.gov (United States)

    Moeck, Christian; Radny, Dirk; Popp, Andrea; Brennwald, Matthias; Stoll, Sebastian; Auckenthaler, Adrian; Berg, Michael; Schirmer, Mario

    2017-12-31

    Knowledge about the residence times of artificially infiltrated water into an aquifer and the resulting flow paths is essential to developing groundwater-management schemes. To obtain this knowledge, a variety of tracers can be used to study residence times and gain information about subsurface processes. Although a variety of tracers exists, their interpretation can differ considerably due to subsurface heterogeneity, underlying assumptions, and sampling and analysis limitations. The current study systematically assesses information gained from seven different tracers during a pumping experiment at a site where drinking water is extracted from an aquifer close to contaminated areas and where groundwater is artificially recharged by infiltrating surface water. We demonstrate that the groundwater residence times estimated using dye and heat tracers are comparable when the thermal retardation for the heat tracer is considered. Furthermore, major ions, acesulfame, and stable isotopes (δ 2 H and δ 18 O) show that mixing of infiltrated water and groundwater coming from the regional flow path occurred and a vertical stratification of the flow system exist. Based on the concentration patterns of dissolved gases (He, Ar, Kr, N 2 , and O 2 ) and chlorinated solvents (e.g., tetrachloroethene), three temporal phases are observed in the ratio between infiltrated water and regional groundwater during the pumping experiment. Variability in this ratio is significantly related to changes in the pumping and infiltration rates. During constant pumping rates, more infiltrated water was extracted, which led to a higher dilution of the regional groundwater. An infiltration interruption caused however, the ratio to change and more regional groundwater is extracted, which led to an increase in all concentrations. The obtained results are discussed for each tracer considered and its strengths and limitations are illustrated. Overall, it is demonstrated that aquifer heterogeneity and

  11. Multiple injected and natural conservative tracers quantify mixing in a stream confluence affected by acid mine drainage near Silverton, Colorado

    Science.gov (United States)

    Schemel, L.E.; Cox, M.H.; Runkel, R.L.; Kimball, B.A.

    2006-01-01

    The acidic discharge from Cement Creek, containing elevated concentrations of dissolved metals and sulphate, mixed with the circumneutral-pH Animas River over a several hundred metre reach (mixing zone) near Silverton, CO, during this study. Differences in concentrations of Ca, Mg, Si, Sr, and SO42- between the creek and the river were sufficiently large for these analytes to be used as natural tracers in the mixing zone. In addition, a sodium chloride (NaCl) tracer was injected into Cement Creek, which provided a Cl- 'reference' tracer in the mixing zone. Conservative transport of the dissolved metals and sulphate through the mixing zone was verified by mass balances and by linear mixing plots relative to the injected reference tracer. At each of seven sites in the mixing zone, five samples were collected at evenly spaced increments of the observed across-channel gradients, as determined by specific conductance. This created sets of samples that adequately covered the ranges of mixtures (mixing ratios, in terms of the fraction of Animas River water, %AR). Concentrations measured in each mixing zone sample and in the upstream Animas River and Cement Creek were used to compute %AR for the reference and natural tracers. Values of %AR from natural tracers generally showed good agreement with values from the reference tracer, but variability in discharge and end-member concentrations and analytical errors contributed to unexpected outlier values for both injected and natural tracers. The median value (MV) %AR (calculated from all of the tracers) reduced scatter in the mixing plots for the dissolved metals, indicating that the MV estimate reduced the effects of various potential errors that could affect any tracer.

  12. Soil and Water Assessment Tool model predictions of annual maximum pesticide concentrations in high vulnerability watersheds.

    Science.gov (United States)

    Winchell, Michael F; Peranginangin, Natalia; Srinivasan, Raghavan; Chen, Wenlin

    2018-05-01

    Recent national regulatory assessments of potential pesticide exposure of threatened and endangered species in aquatic habitats have led to increased need for watershed-scale predictions of pesticide concentrations in flowing water bodies. This study was conducted to assess the ability of the uncalibrated Soil and Water Assessment Tool (SWAT) to predict annual maximum pesticide concentrations in the flowing water bodies of highly vulnerable small- to medium-sized watersheds. The SWAT was applied to 27 watersheds, largely within the midwest corn belt of the United States, ranging from 20 to 386 km 2 , and evaluated using consistent input data sets and an uncalibrated parameterization approach. The watersheds were selected from the Atrazine Ecological Exposure Monitoring Program and the Heidelberg Tributary Loading Program, both of which contain high temporal resolution atrazine sampling data from watersheds with exceptionally high vulnerability to atrazine exposure. The model performance was assessed based upon predictions of annual maximum atrazine concentrations in 1-d and 60-d durations, predictions critical in pesticide-threatened and endangered species risk assessments when evaluating potential acute and chronic exposure to aquatic organisms. The simulation results showed that for nearly half of the watersheds simulated, the uncalibrated SWAT model was able to predict annual maximum pesticide concentrations within a narrow range of uncertainty resulting from atrazine application timing patterns. An uncalibrated model's predictive performance is essential for the assessment of pesticide exposure in flowing water bodies, the majority of which have insufficient monitoring data for direct calibration, even in data-rich countries. In situations in which SWAT over- or underpredicted the annual maximum concentrations, the magnitude of the over- or underprediction was commonly less than a factor of 2, indicating that the model and uncalibrated parameterization

  13. Fracture Characterization in Reactive Fluid-Fractured Rock Systems Using Tracer Transport Data

    Science.gov (United States)

    Mukhopadhyay, S.

    2014-12-01

    Fractures, whether natural or engineered, exert significant controls over resource exploitation from contemporary energy sources including enhanced geothermal systems and unconventional oil and gas reserves. Consequently, fracture characterization, i.e., estimating the permeability, connectivity, and spacing of the fractures is of critical importance for determining the viability of any energy recovery program. While some progress has recently been made towards estimating these critical fracture parameters, significant uncertainties still remain. A review of tracer technology, which has a long history in fracture characterization, reveals that uncertainties exist in the estimated parameters not only because of paucity of scale-specific data but also because of knowledge gaps in the interpretation methods, particularly in interpretation of tracer data in reactive fluid-rock systems. We have recently demonstrated that the transient tracer evolution signatures in reactive fluid-rock systems are significantly different from those in non-reactive systems (Mukhopadhyay et al., 2013, 2014). For example, the tracer breakthrough curves in reactive fluid-fractured rock systems are expected to exhibit a long pseudo-state condition, during which tracer concentration does not change by any appreciable amount with passage of time. Such a pseudo-steady state condition is not observed in a non-reactive system. In this paper, we show that the presence of this pseudo-steady state condition in tracer breakthrough patterns in reactive fluid-rock systems can have important connotations for fracture characterization. We show that the time of onset of the pseudo-steady state condition and the value of tracer concentration in the pseudo-state condition can be used to reliably estimate fracture spacing and fracture-matrix interface areas.

  14. An Efficient Method for Detection of Outliers in Tracer Curves Derived from Dynamic Contrast-Enhanced Imaging

    Directory of Open Access Journals (Sweden)

    Linning Ye

    2018-01-01

    Full Text Available Presence of outliers in tracer concentration-time curves derived from dynamic contrast-enhanced imaging can adversely affect the analysis of the tracer curves by model-fitting. A computationally efficient method for detecting outliers in tracer concentration-time curves is presented in this study. The proposed method is based on a piecewise linear model and implemented using a robust clustering algorithm. The method is noniterative and all the parameters are automatically estimated. To compare the proposed method with existing Gaussian model based and robust regression-based methods, simulation studies were performed by simulating tracer concentration-time curves using the generalized Tofts model and kinetic parameters derived from different tissue types. Results show that the proposed method and the robust regression-based method achieve better detection performance than the Gaussian model based method. Compared with the robust regression-based method, the proposed method can achieve similar detection performance with much faster computation speed.

  15. Nanoparticle tracers in calcium carbonate porous media

    KAUST Repository

    Li, Yan Vivian

    2014-07-15

    Tracers are perhaps the most direct way of diagnosing subsurface fluid flow pathways for ground water decontamination and for natural gas and oil production. Nanoparticle tracers could be particularly effective because they do not diffuse away from the fractures or channels where flow occurs and thus take much less time to travel between two points. In combination with a chemical tracer they can measure the degree of flow concentration. A prerequisite for tracer applications is that the particles are not retained in the porous media as the result of aggregation or sticking to mineral surfaces. By screening eight nanoparticles (3-100 nm in diameter) for retention when passed through calcium carbonate packed laboratory columns in artificial oil field brine solutions of variable ionic strength we show that the nanoparticles with the least retention are 3 nm in diameter, nearly uncharged, and decorated with highly hydrophilic polymeric ligands. The details of these column experiments and the tri-modal distribution of zeta potential of the calcite sand particles in the brine used in our tests suggests that parts of the calcite surface have positive zeta potential and the retention of negatively charged nanoparticles occurs at these sites. Only neutral nanoparticles are immune to at least some retention. © 2014 Springer Science+Business Media.

  16. Accurate assessment of exposure using tracer gas measurements

    DEFF Research Database (Denmark)

    Kierat, Wojciech; Bivolarova, Mariya; Zavrl, Eva

    2018-01-01

    analyzers with short and long response times, respectively. The tracer gas concentration was characterized by the mean, standard deviation and 95th percentile values. The results revealed that the measurement time needed to determine, with sufficient accuracy, these parameters decreased substantially...

  17. Environmental Tracers

    Directory of Open Access Journals (Sweden)

    Trevor Elliot

    2014-10-01

    Full Text Available Environmental tracers continue to provide an important tool for understanding the source, flow and mixing dynamics of water resource systems through their imprint on the system or their sensitivity to alteration within it. However, 60 years or so after the first isotopic tracer studies were applied to hydrology, the use of isotopes and other environmental tracers are still not routinely necessarily applied in hydrogeological and water resources investigations where appropriate. There is therefore a continuing need to promote their use for developing sustainable management policies for the protection of water resources and the aquatic environment. This Special Issue focuses on the robustness or fitness-for-purpose of the application and use of environmental tracers in addressing problems and opportunities scientifically, to promote their wider use and to address substantive issues of vulnerability, sustainability, and uncertainty in (groundwater resources systems and their management.

  18. Uptake and transport of positron-emitting tracer in plants

    Energy Technology Data Exchange (ETDEWEB)

    Kume, Tamikazu; Matsuhashi, Shinpei; Shimazu, Masamitsu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; and others

    1997-03-01

    The transport of a positron-emitting isotope introduced into a plant was dynamically followed by a special observation apparatus called `Positron-Emitting Tracer Imaging System`. In the system, annihilation {gamma}-rays from the positron emitter are detected with two planer detectors (5 x 6 cm square). The water containing ca. 5 MBq/ml of {sup 18}F was fed to the cut stem of soybean for 2 min and then the images of tracer activity were recorded for 30 - 50 min. When the midrib of a leaf near the petiole was cut just before measurement, the activity in the injured leaf was decreased but detected even at the apex. This result suggests that the damaged leaf recovered the uptake of water through the lamina. Maximum tracer activities in leaves of unirradiated plant were observed within 10 min, whereas those of irradiated plant at 100 Gy were observed after over 25 min. The final activity of irradiated plant after 30 min was lower than that of unirradiated plant. In case of beans, there was a difference in the absorption behavior of the {sup 18}F-labeled water between unirradiated and irradiated samples. These results show that the system is effective to observe the uptake and transportation of water containing positron emitting tracer for the study of damage and recovery functions of plants. (author)

  19. Comparison of Large Eddy Simulations and κ-ε Modelling of Fluid Velocity and Tracer Concentration in Impinging Jet Mixers

    Directory of Open Access Journals (Sweden)

    Wojtas Krzysztof

    2015-06-01

    Full Text Available Simulations of turbulent mixing in two types of jet mixers were carried out using two CFD models, large eddy simulation and κ-ε model. Modelling approaches were compared with experimental data obtained by the application of particle image velocimetry and planar laser-induced fluorescence methods. Measured local microstructures of fluid velocity and inert tracer concentration can be used for direct validation of numerical simulations. Presented results show that for higher tested values of jet Reynolds number both models are in good agreement with the experiments. Differences between models were observed for lower Reynolds numbers when the effects of large scale inhomogeneity are important.

  20. Tracer concentration profiles measured in central London as part of the REPARTEE campaign

    Directory of Open Access Journals (Sweden)

    D. Martin

    2011-01-01

    Full Text Available There have been relatively few tracer experiments carried out that have looked at vertical plume spread in urban areas. In this paper we present results from two tracer (cyclic perfluorocarbon experiments carried out in 2006 and 2007 in central London centred on the BT Tower as part of the REPARTEE (Regent's Park and Tower Environmental Experiment campaign. The height of the tower gives a unique opportunity to study vertical dispersion profiles and transport times in central London. Vertical gradients are contrasted with the relevant Pasquill stability classes. Estimation of lateral advection and vertical mixing times are made and compared with previous measurements. Data are then compared with a simple operational dispersion model and contrasted with data taken in central London as part of the DAPPLE campaign. This correlates dosage with non-dimensionalised distance from source. Such analyses illustrate the feasibility of the use of these empirical correlations over these prescribed distances in central London.

  1. Partitioning tracers for measuring residual NAPL: Field-scale test results

    International Nuclear Information System (INIS)

    Annable, M.D.; Rao, P.S.C.; Hatfield, K.; Graham, W.D.; Wood, A.L.; Enfield, C.G.

    1998-01-01

    The difficult task of locating and quantifying nonaqueous phase liquids (NAPLs) present in the vadose and saturated zones has prompted the development of innovative, nondestructive characterization techniques. The use of the interwell partitioning tracer's (IWPT) test, in which tracers that partition into the NAPL phase are displaced through the aquifer, is an attractive alternative to traditional coring and analysis. The first field test of IWPT was conducted in a hydraulically isolated test cell to quantify the total amount of a complex NAPL (a mixture of JP-4 jet fuel and chlorinated solvents) trapped within a 1.5-m smear zone in a shallow, unconfined sand and gravel aquifer at Hill Air Force Base (AFB), Utah. Tracer breakthrough curves (BTCs) were measured in three extraction wells (EWs) following a tracer pulse introduction through four injection wells (IWs). The measured retardation of the partitioning tracer (2,2-dimethyl-3-pentanol) relative to the nonreactive tracer (bromide) was used to quantify the NAPL present. The EW data were used to estimate an average NAPL saturation of 4.6--5.4% within the test cell. NAPL saturations estimated by using measured concentrations in soil cores of two significant compounds present in the NAPL were 3.0 and 4.6%

  2. Development of activable tracers for application in secondary recovering in petroleum reservoirs

    International Nuclear Information System (INIS)

    Martins, Polyana Fabricia Fernandes; Moreira, Rubens Martins . Servico de Meio Ambiente e Tecnicas Nucleares.

    2007-01-01

    Nuclear methods are instrumental in describing detailed flow patterns and other features of oil reservoirs that are unattainable to other methods. Tracer studies in oil fields are performed in a net of injection and producing wells. Thus, the use of only one tracer species would not discriminate the contributions of distinct injection wells to the output of a given production well. Hence, a multi-tracer experiment is required, and the use of activable tracers, capable of being measured by neutron activation analysis (NAA) is here proposed. As additional tracer choices lanthanum (La) and europium (Eu) were chosen from the rare earth series due to their large neutron cross sections and general availability. In order to decrease losses to the oil phase and the retardation of the tracer relatively to the aqueous phase, these elements were complexed with organic chelating ligands: the polyaminocarboxylic acids EDTA, DTPA and DOTA. Infrared spectrometry was used to check complexation. In order to check the partition of the tracer between the aqueous and organic phases, tests were carried stirring the two phases together and measuring the tracer concentrations in the aqueous phase; the partition coefficient (Kao) was then calculated for all the combinations of the two lanthanides and the three ligands. Tests in which the tracer was continuously pumped through reservoir rock samples were also carried out using tritiated water as a reference tracer and the complexed lanthanides. (author)

  3. Tracer studies with aortic infusion result in improper tracer distribution

    International Nuclear Information System (INIS)

    Wisneski, J.A.; Brooks, G.A.; Neese, R.A.; Stanley, W.C.; Morris, D.L.; Gertz, E.W.

    1986-01-01

    It has been suggested that lactate turnover can be accurately assessed by infusing radioactive lactate tracer into the aorta and sampling blood in the vena cava. However, there may be streaming of newly infused tracer in the aorta, resulting in a nonuniform arterial specific activity (SA). Furthermore vena caval blood may not be representative of mixed venous blood. The authors examined this problem in 7 anesthetized dogs with sampling catheters in the pulmonary (PA), carotid (CA), and femoral (FA) arteries, and the superior (SVC) and inferior (IVC) vena cavi. [1- 14 C]lactate was continuously infused into the left ventricle through a catheter introduced through the femoral artery. The same SA (dpm/μmol) was found in the CA and FA, indicating adequate mixing of newly infused tracer with trace. Three dogs showed differences between SVC, IVC and PA, suggesting a mixed venous sample can not be obtained from the VC. When the catheter was moved into the aorta, wide differences in SA appeared between the CA and FA, clearly reflecting streaming of tracer. These differences also appeared in the SVC and IVC. In conclusion, adequate mixing does not occur between tracer and trace in arterial blood with aortic infusion. Further, VC sampling will not give a consistent mixed venous SA. Therefore, for practical reasons, aortic tracer infusion with vena caval sampling will lead to erroneous turnover values

  4. Unit vent airflow measurements using a tracer gas technique

    Energy Technology Data Exchange (ETDEWEB)

    Adams, D.G. [Union Electric Company, Fulton, MO (United States); Lagus, P.L. [Lagus Applied Technology, Inc., San Diego, CA (United States); Fleming, K.M. [NCS Corp., Columbus, OH (United States)

    1997-08-01

    An alternative method for assessing flowrates that does not depend on point measurements of air flow velocity is the constant tracer injection technique. In this method one injects a tracer gas at a constant rate into a duct and measures the resulting concentration downstream of the injection point. A simple equation derived from the conservation of mass allows calculation of the flowrate at the point of injection. Flowrate data obtained using both a pitot tube and a flow measuring station were compared with tracer gas flowrate measurements in the unit vent duct at the Callaway Nuclear Station during late 1995 and early 1996. These data are presented and discussed with an eye toward obtaining precise flowrate data for release rate calculations. The advantages and disadvantages of the technique are also described. In those test situations for which many flowrate combinations are required, or in large area ducts, a tracer flowrate determination requires fewer man-hours than does a conventional traverse-based technique and does not require knowledge of the duct area. 6 refs., 10 figs., 6 tabs.

  5. Site characterization and validation - monitoring of saline tracer transport by borehole radar measurements

    International Nuclear Information System (INIS)

    Olsson, O.; Andersson, P.; Gustafsson, E.

    1991-08-01

    The objective of this experiment was to map tracer transport in fractured crystalline rock through a combination of radar difference tomography and measurements of tracer concentration in boreholes and the validation drift. The experiment was performed twice, first the D-boreholes were used as a sink and then they were replaced by the validation drift and the experiment repeated. In both experiments saline tracer (200 ml/min, 2% salinity) was injected into fracture zone H about 25 m from the validation drift. The experiment revealed an inhomogeneous transmissivity distribution in Zone H. A significant portion of the tracer is transported upwards along Zone H and towards boreholes T1, T2, and W1. The breakthrough data from both experiments indicate that there are two major transport paths from borehole C2 to the D-boreholes/validation drift. One slow and diluted path to the bottom of the drift which carries the bulk of the mass and one fast path to the crown of the drift with high tracer concentration. The radar difference tomograms show that some tracer is lost through Zone S which intersects Zone H and is nearly perpendicular to it. The intersection between the two zones seems to constitute a preferred flow path. The breakthrough data and the radar difference tomograms have also been used to estimate flow porosity. The estimate obtained area of the same order approximately 10 -4 . (au) (28 refs.)

  6. Data volume of atmospheric tracer studies at Lucas Heights, NSW, Australia -1996-1997

    International Nuclear Information System (INIS)

    Clark, G.H.; Stone, D.J.M.; Pascoe, J.H.

    2000-01-01

    A perfluorocarbon atmospheric tracer system has been used to investigate atmospheric dispersion processes in the region surrounding the Lucas Heights Science and Technology Centre. Tracers have been released from two locations: a laboratory vent near the ridge of the Woronora river valley and from the HIFAR research reactor ventilation system. Most studies have been conducted during the early to late morning periods when valley influences might be expected on dispersion of the tracer plume. This report summarises the meteorological and tracer air concentration data and makes comparisons with estimates from a simple gaussian dispersion model. It is intended that the data will also be used for evaluation of more elaborate wind field and atmospheric models

  7. Measurement of the odor impact of a waste deposit using the SF6-tracer method

    International Nuclear Information System (INIS)

    Roetzer, H.; Muehldorf, V.; Riesing, J.

    1994-12-01

    Landfill gas emitted from a waste deposit often causes odor nuisance in the vicinity. For a new sanitary landfill to be established in an area where also other sources of odor existed, very low limits for additional odor nuisance were given by local authorities. To verify that the odor concentrations were below these limit values, the odor contributions of different sources had to be distinguished. Olfactometric methods, using human observers to estimate the intensity of odors, were not applicable to this problem. For direct measurements by analytical methods concentrations of odorous substances were too small. Therefore a tracer method was applied to measure the odor impact of the sanitary landfill to its environment. The emitted landfill gas was labelled with the tracer gas SF 6 . The tracer gas was parted to even amounts and released through ten special nozzles equally distributed over the surface of the landfill. In the area around the landfill the concentration of the tracer gas was measured by collecting air samples and analysing them with a gas chromatograph with an electron capture detector. Fifteen air sampling units were used to collect eight consecutive air samples at each selected point. These measurements gave the relation between the emission of landfill gas and the resulting concentrations in ambient air. With these transmission coefficients the concentrations of odorous gases at the sampling points were evaluated, using the emission concentrations measured by analytical techniques at the landfiIl site. The resulting odor concentrations were compared with values of odor thresholds to establish the odor impact of the waste deposit on the environment. (author)

  8. Chemical Tracer Methods: Chapter 7

    Science.gov (United States)

    Healy, Richard W.

    2017-01-01

    Tracers have a wide variety of uses in hydrologic studies: providing quantitative or qualitative estimates of recharge, identifying sources of recharge, providing information on velocities and travel times of water movement, assessing the importance of preferential flow paths, providing information on hydrodynamic dispersion, and providing data for calibration of water flow and solute-transport models (Walker, 1998; Cook and Herczeg, 2000; Scanlon et al., 2002b). Tracers generally are ions, isotopes, or gases that move with water and that can be detected in the atmosphere, in surface waters, and in the subsurface. Heat also is transported by water; therefore, temperatures can be used to trace water movement. This chapter focuses on the use of chemical and isotopic tracers in the subsurface to estimate recharge. Tracer use in surface-water studies to determine groundwater discharge to streams is addressed in Chapter 4; the use of temperature as a tracer is described in Chapter 8.Following the nomenclature of Scanlon et al. (2002b), tracers are grouped into three categories: natural environmental tracers, historical tracers, and applied tracers. Natural environmental tracers are those that are transported to or created within the atmosphere under natural processes; these tracers are carried to the Earth’s surface as wet or dry atmospheric deposition. The most commonly used natural environmental tracer is chloride (Cl) (Allison and Hughes, 1978). Ocean water, through the process of evaporation, is the primary source of atmospheric Cl. Other tracers in this category include chlorine-36 (36Cl) and tritium (3H); these two isotopes are produced naturally in the Earth’s atmosphere; however, there are additional anthropogenic sources of them.

  9. Tracer experiment by using radioisotope in surface water environment

    International Nuclear Information System (INIS)

    Suh, K.S.; Kim, K.C.; Chun, I.Y.; Jung, S.H.; Lee, C.W.

    2007-01-01

    Complete text of publication follows. 1. Objective An expansion of industrial activities and urbanization result in still increasing amount of pollutants discharged into surface water. Discharged pollutants in surface water have harmful effects on the ecology of a river system and human beings. Pollutants discharged into surface water is transported and dispersed under conditions characteristic to particular natural water receiver. Radiotracer method is a useful tool for monitoring the pollutant dispersion and description of mixing process taking place in natural streams. A tracer experiment using radioisotope was carried out to investigate the characteristics of a pollutant transport and a determination of the diffusion coefficients in a river system. 2. Methods The upper area of the Keum river was selected for the tracer experiment, which is located in a mid west of Korea. The measurements of the velocity and bathymetry before a tracer experiment were performed to select the sampling lines for a detection of the radioisotope. The radioisotope was instantaneously injected into a flow as a point source by an underwater glass-vial crusher. The detection was made with 60 2inch NaI(Tl) scintillation detectors at 3 transverse lines at a downstream position. The multi-channel data acquisition systems were used to collect and process the signals transmitted from the detectors. Two-dimensional numerical models were used to simulate the hydraulic parameters and the concentration distributions of the radioisotope injected into the river. 3. Results and Conclusion The calculated results such as velocity and concentrations were compared with the measured ones. The dispersion characteristics of the radioisotope were analyzed according to a variation of the flow rate, water level and diffusion coefficients. Also, the diffusion coefficients were calculated by using the measured concentrations and the coefficients obtained from the field experiment were compared with the ones

  10. Recent and ancient recharge deciphered by multi-dating tracer technique

    Science.gov (United States)

    Dogramaci, Shawan; Cook, Peter; Mccallum, Jimes; Purtchert, Roland

    2017-04-01

    Determining groundwater residence time from environmental tracer concentrations obtained from open bores or long screened intervals is fraught with difficulty because the sampled water represents variety of ages. Information on the distribution of groundwater age is commonly obtained by measuring more than one tracer. We examined the use of the multi-tracer technique representing different time frames (39Ar, 85Kr, 14C, 3H, CFC 11- CFC-12 CFC-113, SF6 and Cl,) to decipher the groundwater ages sampled from long screened bores in a regional aquifer in the Pilbara region of northwest Australia. We then applied a technique that assumes limited details of the form of the age distribution. Tracer concentrations suggest that groundwater samples are a mixture of young and old water - the former is inferred to represent localised recharge from an adjacent creek, and the latter to be diffuse recharge. Using our method, we were able to identify distinct age components in the groundwater. The results suggest the presence of four distinct age groups; zero and 20 years, 50 to 100 years, 100 to 600 years and approximately 1000 years old. These relatively high recharge events were consistent with local recharge sources (50-100 years) and confirmed by palaeo-climate record obtained from lake sediments. We found that although the ages of these components were well constrained, the relative proportions of each component was highly sensitive to errors of environmental tracer data. Our results show that the method we implemented can identify distinct age groups in groundwater samples without prior knowledge of the age distribution. The presence of distinct recharge times gives insight into groundwater flow conditions over long periods of time.

  11. Application of artificial radioactive tracers for groundwater flow

    International Nuclear Information System (INIS)

    Hamza, M.S.; Aly, A.I.M.; Swailem, F.M.; Nada, A.A.; Awad, M.A.

    1989-01-01

    In this work, the groundwater velocity was estimated by applying radioactive tracer techniques: the single well and the multiple well methods. In the first single well method, radioactive iodine-131 was injected in the well and the radioactivity was monitored with time. The groundwater flow was estimated as a function of the concentration dilution factor of the tracer taking into consideration the permeability of the filter screen and the aquifer. The second method (the multiple well technique) is based on direct measuring of the period of time the tracer needs to disperse from the injection well to one of receptor well arranged in a circle around the injection. The latter method was found to be more accurate and reliable and has also the advantage of determining the groundwater velocity and direction of flow as well. The limitations of the single well technique are discussed and a detailed comparison between single and multi-well techniques is given

  12. Elliptic random-walk equation for suspension and tracer transport in porous media

    DEFF Research Database (Denmark)

    Shapiro, Alexander; Bedrikovetsky, P. G.

    2008-01-01

    . The new theory predicts delay of the maximum of the tracer, compared to the velocity of the flow, while its forward "tail" contains much more particles than in the solution of the classical parabolic (advection-dispersion) equation. This is in agreement with the experimental observations and predictions......We propose a new approach to transport of the suspensions and tracers in porous media. The approach is based on a modified version of the continuous time random walk (CTRW) theory. In the framework of this theory we derive an elliptic transport equation. The new equation contains the time...... of the CTRW theory. (C) 2008 Elsevier B.V. All rights reserved....

  13. Atlantic Coast Unique Regional Atmospheric Tracer Experiment (ACURATE)

    International Nuclear Information System (INIS)

    Schubert, J.F.; Heffter, J.L.; Mead, G.A.

    1983-05-01

    The Atlantic Coast Unique Regional Atmospheric Tracer Experiment (ACURATE) is a program designed to obtain data necessary to evaluate atmospheric transport and diffusion models used to calculate regional population doses caused by nuclear facility emissions to the atmosphere. This experiment will significantly improve the basis for evaluating the cost effectiveness of different methods of managing airborne nuclear wastes. During the period from March 1982 through September 1982, twice daily air samples have been collected at each of five sampling stations located on a radial from the SRP to Murray Hill, NJ (1000 km). Kr-85 emitted from the F and H area chemical separations facilities is being used as a tracer to determine the transport and diffusion of atmospheric releases from the SRP. The Kr-85 concentrations in the air samples will be compared with the calculated concentrations as predicted by the transport and diffusion models. The Kr-85 data and the meteorological data are being archived and will be made available to the modeling community

  14. Using tracers to understand the hydrology of an abandoned underground coal mine

    International Nuclear Information System (INIS)

    Canty, G.A.; Everett, J.W.

    1998-01-01

    Flooded underground mines pose a difficult problem for remediation efforts requiring hydrologic information. Mine environments are hydraulically complicated due to sinuous travel paths and variable hydraulic gradients. For an acidic mine remediation project, conducted by the University of Oklahoma in conjunction with the Oklahoma Conservation Commission, a tracer study was undertaken to identify basic hydrologic properties of a flooded coal mine. The study was conducted to investigate the possibility of in-situ remediation of acidic mine water with the use of alkaline coal combustion by-products. Information on the rate of flow and ''connectiveness'' of injection wells with the discharge point was needed to develop a treatment strategy. Fluorescent dyes are not typically used in mine tracer studies because of the low pH values associated with certain mines and a tendency to adsorb ferric iron precipitates. However, Rhodamine WT was used in one tracer test because it can be detected at low concentrations. Due to poor recovery, a second tracer test was undertaken using a more conservative tracer-chloride. Each tracer produced similar travel time results. Findings from this study suggest that Rhodamine WT can be used under slightly acidic conditions, with mixed results. The more conservative tracer provided somewhat better results, but recovery was still poor. Use of these tracers has provided some valuable information with regard to mine hydrology, but additional questions have been raised

  15. Synthesis of isotopically modified ZnO nanoparticles and their potential as nanotoxicity tracers

    International Nuclear Information System (INIS)

    Dybowska, Agnieszka D.; Croteau, Marie-Noele; Misra, Superb K.; Berhanu, Deborah; Luoma, Samuel N.; Christian, Paul; O'Brien, Paul; Valsami-Jones, Eugenia

    2011-01-01

    Understanding the behavior of engineered nanoparticles in the environment and within organisms is perhaps the biggest obstacle to the safe development of nanotechnologies. Reliable tracing is a particular issue for nanoparticles such as ZnO, because Zn is an essential element and a common pollutant thus present at elevated background concentrations. We synthesized isotopically enriched (89.6%) with a rare isotope of Zn ( 67 Zn) ZnO nanoparticles and measured the uptake of 67 Zn by L. stagnalis exposed to diatoms amended with the particles. Stable isotope technique is sufficiently sensitive to determine the uptake of Zn at an exposure equivalent to lower concentration range ( -1 ). Without a tracer, detection of newly accumulated Zn is significant at Zn exposure concentration only above 5000 μg g -1 which represents some of the most contaminated Zn conditions. Only by using a tracer we can study Zn uptake at a range of environmentally realistic exposure conditions. - ZnO nanoparticles with distinct isotopic composition can be tailor synthesized to be used as tracers of environmental fate and uptake by organisms.

  16. Damage of tracer erythropoietin results in erroneous estimation of concentration in mouse submaxillary gland.

    Science.gov (United States)

    Vidal, A; Carcagno, M; Criscuolo, M; Barcelò, A C; Alippi, R M; Leal, T; Bozzini, C E

    1993-02-01

    It has been previously reported that 1) plasma erythropoietin (Epo) titer during exposure to hypobaria is lower in nephrectomized rats and mice whose submaxillary glands (SMG) were either ablated or atrophied than in nephrectomized controls whose SMG were intact and 2) that the gland shows one of the highest levels of immunoreactive Epo (iEpo) in the body. The latter observation, however, was questioned recently when it was observed that SMG extracts degrade labeled Epo used as tracer antigen in the radioimmunoassay (RIA), thus giving invalid estimates of Epo. Since this interpretation was in turn questioned, the present study was conducted to obtain more information on the subject and make these conflicting points clear. Investigation of the reported/possible degradation of Epo by SMG homogenates was conducted via polyacrylamide gel electrophoresis followed by radioautography or by a RIA in solid phase in which there was no simultaneous incubation of the tracer antigen with the SMG homogenates. It was observed that 125I-labeled rhEpo was degraded when incubated with SMG homogenates. Degradation was rapid, being evident when incubation lasted 30 minutes, and occurred in the presence of a protease inhibitor. It showed a high degree of specificity since it did not occur when Epo was incubated with kidney homogenate or normal mouse serum. SMG homogenate did not degrade labeled thyrotrophic hormone and degraded alpha interferon (IFN-alpha) only partially. When estimates of iEpo in SMG homogenate were performed in conditions of simultaneous (SI-RIA) or nonsimultaneous (NSI-RIA) incubation of the homogenate with tracer Epo, it was observed that while estimates of Epo in plasma were similar in both types of RIA and somewhat higher in kidney homogenate in the SI-RIA than in the NSI-RIA, estimates of Epo in SMG were about 60 times higher in the former than in the latter. Therefore, it could be concluded that most of the Epo detected by standard RIA in SMG homogenate does

  17. Potential tracers for tracking septic tank effluent discharges in watercourses.

    Science.gov (United States)

    Richards, Samia; Withers, Paul J A; Paterson, Eric; McRoberts, Colin W; Stutter, Marc

    2017-09-01

    Septic tank effluent (STE) contributes to catchment nutrient and pollutant loads. To assess the role of STE discharges in impairment of surface water, it is essential to identify the sources of pollution by tracing contaminants in watercourses. We examined tracers that were present in STE to establish their potential for identifying STE contamination in two stream systems (low and high dilution levels) against the background of upstream sources. The studied tracers were microbial, organic matter fluorescence, caffeine, artificial sweeteners and effluent chemical concentrations. The results revealed that tracer concentration ratios Cl/EC, Cl/NH 4 -N, Cl/TN, Cl/TSS, Cl/turbidity, Cl/total coliforms, Cl/sucralose, Cl/saccharin and Cl/Zn had potential as tracers in the stream with low dilution level (P < 0.05). Fluorescence spectroscopy could detect STE inputs through the presence of the tryptophan-like peak, but was limited to water courses with low level of dilution and was positively correlated with stream Escherichia coli (E. coli) and soluble reactive phosphorus (SRP). The results also suggested that caffeine and artificial sweeteners can be suitable tracers for effluent discharge in streams with low and high level of dilution. Caffeine and saccharin were positively correlated with faecal coliforms, E. coli, total P and SRP, indicating their potential to trace discharge of a faecal origin and to be a marker for effluent P. Caffeine and SRP had similar attenuation behaviour in the receiving stream waters suggesting caffeine's potential role as a surrogate indicator for the behaviour of P downstream of effluent inputs. Taken together, results suggest that a single tracer alone was not sufficient to evaluate STE contamination of watercourses, but rather a combination of multiple chemical and physical tracing approaches should be employed. A multiple tracing approach would help to identify individual and cumulative STE inputs that pose risks to stream waters in

  18. Can radiocaesium be used as a tracer for vegetal nutrients?

    International Nuclear Information System (INIS)

    Anjos, R. M.; Mosquera, B.; Carvalho, C.; Sanches, N.; Bastos, J.; Macario, K.; Vezzone, M.; Gomes, P.R.S.

    2007-01-01

    In recent years, there has been a growing interest in the evaluation of nutrient fluxes and radioactive contaminants in forest and agricultural ecosystems. Several studies on forest ecosystems have been carried out, mostly in Europe, after the Chernobyl accident. These studies have been performed mainly in the development of models for predicting the radiocaesium behavior in the soil and plant compartments of forest systems. However, research on the use of radiocaesium as a tracer for vegetal nutrients has shown that, despite the fact that caesium is a weakly hydrated alkaline metal and has chemical similarities to potassium and ammonium, this is still a complex problem requiring, then, more experimental results. Additionally, very little is known about the mechanisms involved in the radionuclide uptake and retention by tropical plants. In order to contribute to the understanding of the relative behavior of caesium, potassium and ammonium and to investigate whether radiocaesium can be used as a tracer for vegetal nutrients, the Laboratory of Radioecology (LARA) of the Federal Fluminense University has been performing analysis of 137 Cs, 40 K and NH 4 concentrations in several vegetal compartments of agricultural tropical plants, such as guava (Psidium guajava), mango (Mangifera indica), avocado (Persea americana), pomegranate (Punica granatum), papaya (Carica Papaya), banana (Musa paradisiaca), manioc (Manihot Esculenta), and chili pepper (Capsicum fructescens) trees. Measurements of 137 Cs, 40 K and NH 4 concentrations show that these elements can be very mobile within a plant, exhibiting the highest values of concentration in the growing parts of the trees: fruits, leaves, twigs, barks and the outer growth layers. On the other hand, our results indicate that for wood trees (such as guava, mango, avocado, pomegranate and chili pepper trees) do both caesium and the vegetal nutrients have simultaneously higher concentrations in the youngest rather than in the oldest

  19. Theoretical model of intravascular paramagnetic tracers effect on tissue relaxation

    DEFF Research Database (Denmark)

    Kjølby, Birgitte Fuglsang; Østergaard, Leif; Kiselev, Valerij G

    2006-01-01

    The concentration of MRI tracers cannot be measured directly by MRI and is commonly evaluated indirectly using their relaxation effect. This study develops a comprehensive theoretical model to describe the transverse relaxation in perfused tissue caused by intravascular tracers. The model takes...... into account a number of individual compartments. The signal dephasing is simulated in a semianalytical way by embedding Monte Carlo simulations in the framework of analytical theory. This approach yields a tool for fast, realistic simulation of the change in the transverse relaxation. The results indicate...... with bulk blood. The enhancement of relaxation in tissue is due to the contrast in magnetic susceptibility between blood vessels and parenchyma induced by the presence of paramagnetic tracer. Beyond the perfusion measurements, the results can be applied to quantitation of functional MRI and to vessel size...

  20. Tracer tests and image analysis of biological clogging in a two-dimentsional sandbox experiment

    DEFF Research Database (Denmark)

    Kildsgaard, J.; Engesgaard, Peter Knudegaard

    2002-01-01

    A two-dimensional flow experiment on biological clogging was carried out by biostimulating a sandbox packed with sand inoculated with bacteria. Biostimulation. consisted of continuously injecting nutrients (acetate and nitrate). Clogging was visualized by frequently carrying out colored tracer...... experiments using Brilliant Blue. The tracer experiments were recorded with a digital camera and converted to concentration maps using an image-analysis method that revealed in detail the complex spreading pattern surrounding clogged areas. Clogging resulted in a finger-like spreading of the tracer around...

  1. Multiple injected and natural conservative tracers quantify mixing in a stream confluence affected by acid mine drainage near Silverton, Colorado

    Science.gov (United States)

    Schemel, Laurence E.; Cox, Marisa H.; Runkel, Robert L.; Kimball, Briant A.

    2006-08-01

    The acidic discharge from Cement Creek, containing elevated concentrations of dissolved metals and sulphate, mixed with the circumneutral-pH Animas River over a several hundred metre reach (mixing zone) near Silverton, CO, during this study. Differences in concentrations of Ca, Mg, Si, Sr, and SO42- between the creek and the river were sufficiently large for these analytes to be used as natural tracers in the mixing zone. In addition, a sodium chloride (NaCl) tracer was injected into Cement Creek, which provided a Cl- reference tracer in the mixing zone. Conservative transport of the dissolved metals and sulphate through the mixing zone was verified by mass balances and by linear mixing plots relative to the injected reference tracer. At each of seven sites in the mixing zone, five samples were collected at evenly spaced increments of the observed across-channel gradients, as determined by specific conductance. This created sets of samples that adequately covered the ranges of mixtures (mixing ratios, in terms of the fraction of Animas River water, %AR). Concentratis measured in each mixing zone sample and in the upstream Animas River and Cement Creek were used to compute %AR for the reference and natural tracers. Values of %AR from natural tracers generally showed good agreement with values from the reference tracer, but variability in discharge and end-member concentrations and analytical errors contributed to unexpected outlier values for both injected and natural tracers. The median value (MV) %AR (calculated from all of the tracers) reduced scatter in the mixing plots for the dissolved metals, indicating that the MV estimate reduced the effects of various potential errors that could affect any tracer.

  2. Tracer techniques for urine volume determination and urine collection and sampling back-up system

    Science.gov (United States)

    Ramirez, R. V.

    1971-01-01

    The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.

  3. The field tracer test study of atmospheric dispersion in Fujian Huian Nuclear Power Plant site

    International Nuclear Information System (INIS)

    Hu Erbang; Xin Cuntian; Yan Jiangyu; Ren Zhiqiang; Xuan Yiren; Jia Peirong

    2003-01-01

    The SF 6 tracer tests and its main results completed in site of Fujian Huian Nuclear Power Plant during summer, 2002, are described. A total of 15 times of SF 6 tracer tests were done in the July, in which the time of atmospheric stability B, C, D, E is respectively 3, 2, 9, 1 based on ΔT-U method and the time of B, D, E is respectively 1, 11, 3 based on ΔT method. About 50 samples were collected in each SF 6 tracer tests, the maximum of sample distance from the tower in which the SF 6 tracer was released is about 15 km. The values of p y , p z , q y , q z in the formula of diffusion parameters is determined. Finally the above diffusion parameters are compared with P-G curve, Briggs diffusion parameters and those obtained from turbulence observation and wind tunnel simulation test done in the past time. (authors)

  4. In-EDTA as activable tracer in hydrogeological investigations

    International Nuclear Information System (INIS)

    Stanescu, S.P.; Gaspar, E.; Spiridon, S.; Farcasiu, O.M.; Catilina, R.

    1982-12-01

    Two experiments are presented, on the possibilities of the use of indium in the form of the In-EDTA complex, as an activable tracer for hydrogeological studies. The determination of indium concentrations in the sampled water has been carried out by using the coprecipitation of indium with bismuth hydroxide, the neutron activation at the VVR-S reactor of the Institute for Nuclear Physics and Engineering - Bucharest and the measurement on the 417.0 keV line of sup(116m)In with the Ge(Li) spectrometric device. The advantages of the utilization of In-EDTA as a tracer for marking large volumes of water and of some long transit waters (of the order of months) have resulted. (authors)

  5. Radio-isotopic tracers

    International Nuclear Information System (INIS)

    Wolfangel, R.G.

    1976-01-01

    The invention concerns the dispersions that may be used for preparing radio-isotopic tracers, technetium labelled dispersions, processes for preparing these dispersions and their use as tracers. Technetium 99m sulphur colloids are utilized as scintillation tracers to give a picture of the reticulo-endothelial system, particularly the liver and spleen. A dispersion is provided which only requires the addition of a radioactive nuclide to form a radioactively labelled dispersion that can be injected as a tracer. It is formed of a colloid of tin sulphur dispersed in an aqueous buffer solution. Such a reagent has the advantage of being safe and reliable and is easier to use. The colloid can be prepared more quickly since additions of several different reagents are avoided. There is no need to heat up and no sulphuretted hydrogen, which is a toxic gas, is used [fr

  6. Influence of the composition of radionuclide mixtures on the maximum permissible concentration

    International Nuclear Information System (INIS)

    Schillinger, K.; Schuricht, V.

    1975-08-01

    By dividing radionuclides according to their formation mechanisms it is possible to assess the influence of separate partial mixtures on the maximum permissible concentration (MPC) of the total mixture without knowing exactly their contribution to the total activity. Calculations showed that the MPC of a total mixture of unsoluble radionuclides, which may occur in all fields of peaceful uses of nuclear energy, depends on the gastrointestinal tract as the critical organ and on the composition of the fission product mixture. The influence of fractionation on the MPC can be reglected in such a case, whereas in case of soluble radionuclides this is not possible

  7. Use of tracers to quantify subsurface flow through a mining pit.

    Science.gov (United States)

    Schladow, S Geoffrey; Clark, Jordan F

    2008-12-01

    Three independent tracer experiments were conducted to quantify the through-flow of water from Herman Pit, an abandoned mercury (Hg) mine pit adjacent to Clear Lake, California, USA. The tracers used were Rhodamine-WT, sulfur hexafluoride, and a mixture of sulfur hexafluoride and neon-22. The tracers were injected into Herman Pit, a generally well-mixed water body of approximately 81,000 m2, and the concentrations were monitored in the mine pit, observation wells, and the lake for 2-3 months following each injection. The results for all three experiments showed that the tracer arrived at certain observation wells within days of injection. Comparing all the well data showed a highly heterogeneous response, with a small number of wells showing this near-instantaneous response and others taking months before the tracer was detectable. Tracer was also found in the lake on four occasions over a one-month period, too few to infer any pattern but sufficient to confirm the connection of the two water bodies. Using a simple mass balance model it was possible to determine the effective loss rate through advection for each of the tracers and with this to estimate the through-flow rate. The through-flow rate for all three experiments was approximately 630 L/s, at least 1-2 orders of magnitude larger than previous estimates, all of which had been based on geochemical inferences or other indirect measures of the pit through-flow.

  8. Dynamic dual-tracer PET reconstruction.

    Science.gov (United States)

    Gao, Fei; Liu, Huafeng; Jian, Yiqiang; Shi, Pengcheng

    2009-01-01

    Although of important medical implications, simultaneous dual-tracer positron emission tomography reconstruction remains a challenging problem, primarily because the photon measurements from dual tracers are overlapped. In this paper, we propose a simultaneous dynamic dual-tracer reconstruction of tissue activity maps based on guidance from tracer kinetics. The dual-tracer reconstruction problem is formulated in a state-space representation, where parallel compartment models serve as continuous-time system equation describing the tracer kinetic processes of dual tracers, and the imaging data is expressed as discrete sampling of the system states in measurement equation. The image reconstruction problem has therefore become a state estimation problem in a continuous-discrete hybrid paradigm, and H infinity filtering is adopted as the estimation strategy. As H infinity filtering makes no assumptions on the system and measurement statistics, robust reconstruction results can be obtained for the dual-tracer PET imaging system where the statistical properties of measurement data and system uncertainty are not available a priori, even when there are disturbances in the kinetic parameters. Experimental results on digital phantoms, Monte Carlo simulations and physical phantoms have demonstrated the superior performance.

  9. Description and results of tracer tests conducted for a deep fracture zone within granitic rock at the Leuggern borehole

    International Nuclear Information System (INIS)

    Spane, F.A. jr.

    1990-09-01

    A tracer test program was planned at the Leuggern borehole, to provide hydrogeologic information concerning the fracture zone(s) intersected within the depth interval 1,634.9 - 1,688.9 m. The original design of the tracer-dilution test was to: establish a uniform tracer concentration within the test system, and then monitor (at ground surface) the decline of tracer concentration within the circulated test system fluid. Analysis of the tracer concentration decline pattern was expected to provide an estimate of the natural lateral flux and lateral hydraulic gradient for the isolated test interval. A later pump-back test was also designed to recover tracer that had been 'flushed' into the test section, during the previous closed-circulation period. Analysis of the tracer recovery pattern was expected to provide an estimate of the dispersivity within the intersected fracture system. Results obtained from 'arrival-time' information during the Eosin and Naphtionat injection/recovery phases indicate a downward vertical flow of approximately 195-225 ml/min in the isolated interval, from an analysis of the dilution levels of Uranin and Eosin during the injection/recovery periods, and review of field data, the top of the upper inflow zone was determined to be approximately 13 m below the top flow line and the bottom of the outflow zone to be approximately 3 to 5 meters above the bottom flow line. (author) 30 figs., tabs., 42 refs

  10. Development of radioisotope tracer technology

    International Nuclear Information System (INIS)

    Jin, Joon Ha; Lee, Myun Joo; Jung, Sung Hee; Park, Soon Chul; Lim, Dong Soon; Kim, Jae Ho; Lee, Jae Choon; Lee, Doo Sung; Cho, Yong Suk; Shin, Sung Kuan

    2000-04-01

    The purpose of this study is to develop the radioisotope tracer technology, which can be used in solving industrial and environmental problems and to build a strong tracer group to support the local industries. In relation to the tracer technology in 1999, experiments to estimate the efficiencies of a sludge digester of a waste water treatment plant and a submerged biological reactor of a dye industry were conducted. As a result, the tracer technology for optimization of facilities related to wastewater treatment has been developed and is believed to contribute to improve their operation efficiency. The quantification of the experimental result was attempted to improve the confidence of tracer technology by ECRIN program which basically uses the MCNP simulation principle. Using thin layer activation technique, wear of tappet shim was estimated. Thin layer surface of a tappet shim was irradiated by proton beam and the correlation between the measured activity loss and the amount of wear was established. The equipment was developed to adjust the energy of proton which collides with the surface of tappet. The tracer project team has participated into the tracer test for estimating the efficiency of RFCC system in SK cooperation. From the experiment the tracer team has obtained the primary elements to be considered for judging the efficiency of RFCC unit. By developing the tracer techniques to test huge industrial units like RFCC, the tracer team will be able to support the local industries that require technical services to solve any urgent trouble. (author)

  11. Quadratic tracer dynamical models tobacco growth

    International Nuclear Information System (INIS)

    Qiang Jiyi; Hua Cuncai; Wang Shaohua

    2011-01-01

    In order to study the non-uniformly transferring process of some tracer dosages, we assume that the absorption of some tracer by tobacco is a quadratic function of the tracer quantity of the tracer in the case of fast absorption, whereas the exclusion of the tracer from tobacco is a linear function of the tracer quantity in the case of slow exclusion, after the tracer is introduced into tobacco once at zero time. A single-compartment quadratic dynamical model of Logistic type is established for the leaves of tobacco. Then, a two-compartment quadratic dynamical model is established for leaves and calms of the tobacco. Qualitative analysis of the models shows that the tracer applied to the leaves of the tobacco is excluded finally; however, the tracer stays at the tobacco for finite time. Two methods are also given for computing the parameters in the models. Finally, the results of the models are verified by the 32 P experiment for the absorption of tobacco. (authors)

  12. MESYST, Simulation of 3-D Tracer Dispersion in Atmosphere

    International Nuclear Information System (INIS)

    Mastrangelo, V.; Mehilli, I.

    2000-01-01

    1 - Description of program or function: Mesyst code is used for the simulation of 3D tracer dispersion in atmosphere. Three packages are part of this system: Cre-topo: prepares the terrain data for the Mesyst. Noabl: code calculates three- dimensional free divergence wind fields over complex terrain. Pas: Computing of tracer concentrations and depositions on a given domain. 2 - Method of solution: NOABL - Line Over Relaxation + Special adaptation of Gauss procedure. PAS - Monte Carlo Method. 3 - Restrictions on the complexity of the problem: Computations: Mesh size: variable from some meters to some hundreds meters Mesh number: variable depending on available real data (some hundreds points on each directions)

  13. Tracers and tracing methods

    International Nuclear Information System (INIS)

    Leclerc, J.P.

    2001-01-01

    The first international congress on 'Tracers and tracing methods' took place in Nancy in May 2001. The objective of this second congress was to present the current status and trends on tracing methods and their applications. It has given the opportunity to people from different fields to exchange scientific information and knowledge about tracer methodologies and applications. The target participants were the researchers, engineers and technologists of various industrial and research sectors: chemical engineering, environment, food engineering, bio-engineering, geology, hydrology, civil engineering, iron and steel production... Two sessions have been planned to cover both fundamental and industrial aspects: 1)fundamental development (tomography, tracer camera visualization and particles tracking; validation of computational fluid dynamics simulations by tracer experiments and numerical residence time distribution; new tracers and detectors or improvement and development of existing tracing methods; data treatments and modeling; reactive tracer experiments and interpretation) 2)industrial applications (geology, hydrogeology and oil field applications; civil engineering, mineral engineering and metallurgy applications; chemical engineering; environment; food engineering and bio-engineering). The program included 5 plenary lectures, 23 oral communications and around 50 posters. Only 9 presentations are interested for the INIS database

  14. Use of radioactive and neutron-activatable tracers to determine effective hydrogeologic parameters

    International Nuclear Information System (INIS)

    Yu, C.; Jester, W.A.; Jarrett, A.R.

    1985-01-01

    The migration of nuclides in a geologic medium is controlled by the hydrogeologic parameters of the medium such as the dispersion coefficient, pore water velocity, retardation factor, degradation rate, mass transfer coefficient, water content, and fraction of dead-end pores. The breakthrough curve (BTC), which is the graphical relationship between the tracer concentration and the elapsed time since introduction, is an integrated picture of the hydrogeologic parameters that produced the BTC. Both radioactive and neutron-activatable tracers have been used to generate BTCs. The BTC of a 92 Br radioactive tracer generated under saturated conditions in a nonhomogeneous (fractured) soil column is shown. From BTCs, the effective hydrogeologic parameters can be identified if appropriate techniques are applied

  15. Synthesis of isotopically modified ZnO nanoparticles and their potential as nanotoxicity tracers

    Energy Technology Data Exchange (ETDEWEB)

    Dybowska, Agnieszka D., E-mail: a.dybowska@nhm.ac.u [Department of Mineralogy, Natural History Museum London, Cromwell Road, London, SW7 5BD (United Kingdom); Croteau, Marie-Noele [U.S. Geological Survey, 345 Middlefield Road, MS 496, Menlo Park, CA 94025 (United States); Misra, Superb K.; Berhanu, Deborah [Department of Mineralogy, Natural History Museum London, Cromwell Road, London, SW7 5BD (United Kingdom); Luoma, Samuel N. [Department of Mineralogy, Natural History Museum London, Cromwell Road, London, SW7 5BD (United Kingdom); U.S. Geological Survey, 345 Middlefield Road, MS 496, Menlo Park, CA 94025 (United States); Christian, Paul; O' Brien, Paul [School of Chemistry, University of Manchester, M13 9PL, Manchester (United Kingdom); Valsami-Jones, Eugenia [Department of Mineralogy, Natural History Museum London, Cromwell Road, London, SW7 5BD (United Kingdom)

    2011-01-15

    Understanding the behavior of engineered nanoparticles in the environment and within organisms is perhaps the biggest obstacle to the safe development of nanotechnologies. Reliable tracing is a particular issue for nanoparticles such as ZnO, because Zn is an essential element and a common pollutant thus present at elevated background concentrations. We synthesized isotopically enriched (89.6%) with a rare isotope of Zn ({sup 67}Zn) ZnO nanoparticles and measured the uptake of {sup 67}Zn by L. stagnalis exposed to diatoms amended with the particles. Stable isotope technique is sufficiently sensitive to determine the uptake of Zn at an exposure equivalent to lower concentration range (<15 {mu}g g{sup -1}). Without a tracer, detection of newly accumulated Zn is significant at Zn exposure concentration only above 5000 {mu}g g{sup -1} which represents some of the most contaminated Zn conditions. Only by using a tracer we can study Zn uptake at a range of environmentally realistic exposure conditions. - ZnO nanoparticles with distinct isotopic composition can be tailor synthesized to be used as tracers of environmental fate and uptake by organisms.

  16. Tracer dating and ocean ventilation

    International Nuclear Information System (INIS)

    Thiele, G.; Sarmiento, J.L.

    1990-01-01

    The interpretation of transient tracer observations depends on difficult to obtain information on the evolution in time of the tracer boundary conditions and interior distributions. Recent studies have attempted to circumvent this problem by making use of a derived quantity, age, based on the simultaneous distribution of two complementary tracers, such as tritium and its daughter, helium 3. The age is defined with reference to the surface such that the boundary condition takes on a constant value of zero. The authors use a two-dimensional model to explore the circumstances under which such a combination of conservation equations for two complementary tracers can lead to a cancellation of the time derivative terms. An interesting aspect of this approach is that mixing can serve as a source or sink of tracer based age. The authors define an idealized ventilation age tracer that is conservative with respect to mixing, and they explore how its behavior compares with that of the tracer-based ages over a range of advective and diffusive parameters

  17. Tracer Flux Balance at an Urban Canyon Intersection

    Science.gov (United States)

    Carpentieri, Matteo; Robins, Alan G.

    2010-05-01

    Despite their importance for pollutant dispersion in urban areas, the special features of dispersion at street intersections are rarely taken into account by operational air quality models. Several previous studies have demonstrated the complex flow patterns that occur at street intersections, even with simple geometry. This study presents results from wind-tunnel experiments on a reduced scale model of a complex but realistic urban intersection, located in central London. Tracer concentration measurements were used to derive three-dimensional maps of the concentration field within the intersection. In combination with a previous study (Carpentieri et al., Boundary-Layer Meteorol 133:277-296, 2009) where the velocity field was measured in the same model, a methodology for the calculation of the mean tracer flux balance at the intersection was developed and applied. The calculation highlighted several limitations of current state-of-the-art canyon dispersion models, arising mainly from the complex geometry of the intersection. Despite its limitations, the proposed methodology could be further developed in order to derive, assess and implement street intersection dispersion models for complex urban areas.

  18. Uptake and transport of positron-emitting tracer (18F) in plants

    International Nuclear Information System (INIS)

    Kume, Tamikazu; Matsuhashi, Shinpei; Shimazu, Masamitsu

    1997-01-01

    The transport of a positron-emitting isotope introduced into a plant was dynamically followed by a special observation apparatus called Positron-Emitting Tracer Imaging System' to observe the damage and recovery functions of plants in vivo. In the system, annihilation γ-rays from the positron emitter are detected with two planar detectors (5 x 6 cm 2 ). The water containing ca. 5 MBq/ml of 18 F was fed to the cut stem of soybean for 2 min and then the images of tracer activity were recorded for 30-50 min. When the midrib of a leaf near the petiole was cut just before measurement, the activity in the injured leaf was decreased but detected even at the apex. This result suggests that the damaged leaf recovered the uptake of water through the lamina. Maximum tracer activities in leaves of unirradiated plant were observed within 10 min, whereas those of irradiated plant at 100 Gy were observed after over 25 min. The final activity of irradiated plant after 30 min was lower than that of unirradiated plant. In case of beans, there was a difference in the absorption behavior of the 18 F-labeled water between unirradiated and irradiated samples. These results show that the system is effective to observe the uptake and transportation of water containing positron emitting tracer for the study of damage and recovery functions of plants. (Author)

  19. Simulation of tracer transport for the site characterization and validation site in the Stripa Mine

    International Nuclear Information System (INIS)

    Long, J.C.S.; Karasaki, K.

    1992-01-01

    This report describes a series of numerical simulations of tracer tests that were performed in a fracture zone (the H-zone) at the Stripa Mine in Sweden. The tracer simulations are bases on Equivalent Discontinuum models which were developed bases on geophysical measurements and hydraulic interference data (Long et al., 1992). The transport simulations are calibrated to one set of saline tracer breakthrough curves (from the first radar/saline experiment, RSI) and these calibrated models are used to predict another series of breakthrough curves. Predicted breakthrough curves can be compared to the actual data and simulated ''snapshots'' of concentration in the plan of the fracture zone can be compared to radar difference tomograms made during the saline tracer experiments

  20. Suitability of tracers

    International Nuclear Information System (INIS)

    Klotz, D.

    1999-01-01

    Hydrological tracer techniques are a means of making statements on the direction and speed of underground water. One of the simpler tasks is to find out whether there is hydrological communication between two given points. This requires a determination of the direction of flow, which places less exacting demands on the properties of the tracer than does the task of determining the flow velocity of underground water. Tracer methods can serve to infer from flow velocity the distance (flow) velocity, which is defined as the ratio between the distance between two points located in flow direction and the actual time it takes water to flow from one to the other [de

  1. Tests of regional elemental tracers of pollution aerosols. 1. Distinctness of regional signatures, stability during transport, and empirical validation

    International Nuclear Information System (INIS)

    Lowenthal, D.H.; Wunschel, K.R.; Rahn, K.A.

    1988-01-01

    The two major requirements for a successful regional tracer system are distinctness of signatures and stability of signatures during transport. Dissimilarity of the five regional signatures from eastern North America is shown by collinearity diagnostics and by apportionment of synthetic samples generated randomly. Stability of regional signatures during transport is shown first by use of tracer elements in coarse and fine aerosol to predict the maximum possible change of ratios from particle-size effects alone and then by examination of actual changes in signatures during transport from the Midwest to Underhill, VT. Two recent empirical validations of the tracer system are presented: qualitative agreement of pulses of mid-western aerosol in Vermont with pulses of perfluorocarbon tracer gas released in Ohio during CAPTEX '83 and reproduction of our three major northeastern and mid-western signatures by other investigators. The tracer system currently uses the seven elements As, Se, Sb, Zn, In, noncrustal Mn, and noncrustal V as measured by instrumental neutron activation

  2. MAK and BAT values list 2017. Maximum permissible concentrations at the place of work and biological tolerance values for working materials

    International Nuclear Information System (INIS)

    2017-01-01

    The MAK and BAT values list 2017 includes the maximum permissible concentrations at the place of work and biological tolerance values for working materials. The following working materials are covered: carcinogenic working materials, sensitizing materials and aerosols. The report discusses the restriction of exposure peaks, skin resorption, MAK (maximum working place concentration) values during pregnancy, germ cell mutagens and specific working materials. Importance and application of BAT (biological working material tolerance) values, list of materials, carcinogens, biological guide values and reference values are also included.

  3. MAK and BAT values list 2016. Maximum permissible concentrations at the place of work and biological tolerance values for working materials

    International Nuclear Information System (INIS)

    2016-01-01

    The MAK and BAT values list 2016 includes the maximum permissible concentrations at the place of work and biological tolerance values for working materials. The following working materials are covered: carcinogenic working materials, sensitizing materials and aerosols. The report discusses the restriction of exposure peaks, skin resorption, MAK (maximum working place concentration) values during pregnancy, germ cell mutagens and specific working materials. Importance and application of BAT (biological working material tolerance) values, list of materials, carcinogens, biological guide values and reference values are also included.

  4. Development of some new Aza and Thia complex as alternative tracers for oil reservoirs

    International Nuclear Information System (INIS)

    Silva, Lauris L.; Donnici, Claudio L.; Ayala, Jose D.

    2009-01-01

    A promising group of non-sorbing tracers are lanthanide ions complexed to organic anions, which yield a negatively charged complex. Besides, this lanthanide ion could be chosen which, in its non-complexed form, is very insoluble in groundwater and thus no severe background concentrations problem would arise. The lanthanide elements may be used as tracers since they present good solubility in water, when complexed, and the nuclides have high neutron cross sections, they may be used as activable tracers under neutron irradiation in order to evaluate the efficiency of the petroleum production processes. For this purpose, tracers must be soluble in the aqueous phase and be insoluble in the organic phase, they also must not be adsorbed on the internal microporous rock formations and be easily detectable. Lanthanide complexes with DTPA and thiodicarboxylic acid ligands are an alternative to the development of these novel tracers since their properties may be chemically adjusted. (author)

  5. Use of MICRAS code on the evaluation of the maximum radionuclides concentrations due to transport/migration of decay chain in groundwaters

    International Nuclear Information System (INIS)

    Aquino Branco, O.E. de

    1995-01-01

    This paper presents a methodology for the evaluation of the maximum radionuclides concentrations in groundwaters, due to the transport/migration of decay chains. Analytical solution of the equations system is difficult, even if only three elements of the decay chain are considered. Therefore, a numerical solution is most convenient. An application of the MICRAS code, developed to assess maximum concentrations of each radionuclide, starting with the initial concentrations, is presented. The maximum concentration profile for 226 Ra, calculated using MICRAS, is compared with the results obtained through an analytical and a numerical model. The fitness of results is considered good. Simplified models, like the one represented by the application of MICRAS, are largely employed in the section in the selection and characterization of sites for radioactive wastes repositories and in studies of safety evaluation for the same purpose. A detailed analysis of the transport/migration of contaminants in aquifers requires a large quantify of data from the site and from the installation as well, which makes this analysis expensive and inviable during the preliminary phases of the studies. (author). 6 refs, 1 fig, 1 tab

  6. Packet Tracer network simulator

    CERN Document Server

    Jesin, A

    2014-01-01

    A practical, fast-paced guide that gives you all the information you need to successfully create networks and simulate them using Packet Tracer.Packet Tracer Network Simulator is aimed at students, instructors, and network administrators who wish to use this simulator to learn how to perform networking instead of investing in expensive, specialized hardware. This book assumes that you have a good amount of Cisco networking knowledge, and it will focus more on Packet Tracer rather than networking.

  7. Key aspects of stratospheric tracer modeling using assimilated winds

    Directory of Open Access Journals (Sweden)

    B. Bregman

    2006-01-01

    Full Text Available This study describes key aspects of global chemistry-transport models and their impact on stratospheric tracer transport. We concentrate on global models that use assimilated winds from numerical weather predictions, but the results also apply to tracer transport in general circulation models. We examined grid resolution, numerical diffusion, air parcel dispersion, the wind or mass flux update frequency, and time interpolation. The evaluation is performed with assimilated meteorology from the "operational analyses or operational data" (OD from the European Centre for Medium-Range Weather Forecasts (ECMWF. We also show the effect of the mass flux update frequency using the ECMWF 40-year re-analyses (ERA40. We applied the three-dimensional chemistry-transport Tracer Model version 5 (TM5 and a trajectory model and performed several diagnoses focusing on different transport regimes. Covering different time and spatial scales, we examined (1 polar vortex dynamics during the Arctic winter, (2 the large-scale stratospheric meridional circulation, and (3 air parcel dispersion in the tropical lower stratosphere. Tracer distributions inside the Arctic polar vortex show considerably worse agreement with observations when the model grid resolution in the polar region is reduced to avoid numerical instability. The results are sensitive to the diffusivity of the advection. Nevertheless, the use of a computational cheaper but diffusive advection scheme is feasible for tracer transport when the horizontal grid resolution is equal or smaller than 1 degree. The use of time interpolated winds improves the tracer distributions, particularly in the middle and upper stratosphere. Considerable improvement is found both in the large-scale tracer distribution and in the polar regions when the update frequency of the assimilated winds is increased from 6 to 3 h. It considerably reduces the vertical dispersion of air parcels in the tropical lower stratosphere. Strong

  8. Proceedings of the atmospheric tracers and tracer application workshop

    International Nuclear Information System (INIS)

    Barr, S.; Gedayloo, T.

    1979-12-01

    In addition to presentations by participating members a general discussion was held in order to summarize and outline the goals and objectives of the workshop. A number of new low level background tracers such as heavy methanes, perfluorocarbons, multiply labeled isotopes such as 13 C 18 O 2 , helium 3, in addition to sample collection techniques and analytical methods for various tracers were discussed. This report is a summary of discussions and papers presented at this workshop

  9. Use of artificial tracers in hydrology

    International Nuclear Information System (INIS)

    1991-05-01

    The IAEA has convened an Advisory Group Meeting with the following objectives: To define the role of artificial radioactive tracers for water tracing in comparison with other non-radioactive tracers. To evaluate the real needs of artificial radioactive tracers in hydrology. To identify the fields for which artificial radioactive tracers are useful as well as those in which they can be substituted by other tracers. To discuss the strategy to be adopted to overcome the difficulties derived from the restrictions on the use of radioactive tracers in hydrology. The meeting was held at IAEA Headquarters from 19 to 22 March 1990, and was attended by 30 participants from 15 Member States. The conclusions and recommendations are that the use of artificial radioactive tracers should be restricted to cases where other tracers cannot be used or do not provide the same quality of information. Tritium, iodine-131, bromine-82, chromium-51 in the form of Cr-EDTA, technetium-99m obtained from 99 Mo-generators and gold-198 as an adsorbable tracer are, practically, the only radionuclides used for water tracing. The use of other radionuclides for this purpose does not appear to be necessary, possible and/or convenient. Refs, figs and tabs

  10. Fluorescence tracers as a reference for pesticide transport in wetland systems

    Science.gov (United States)

    Lange, Jens; Passeport, Elodie; Tournebize, Julien

    2010-05-01

    Two different fluorescent tracers, Uranine (UR) and Sulforhodamine (SRB), were injected as a pulse into surface flow wetlands. Tracer breakthrough curves were used to document hydraulic efficiencies, peak attenuation and retention capacities of completely different wetland systems. The tracers were used as a reference to mimic photolytic decay (UR) and sorption (SRB) of contaminants, since a real herbicide (Isoproturon, IPU) was injected in parallel to UR and SRB. Analysis costs limited IPU sampling frequency and single samples deviated from the tracer breakthrough curves. Still, a parallel behavior of IPU and SRB could be observed in totally different wetland systems, including underground passage through drainage lines. Similar recovery rates for IPU and SRB confirmed this observation. Hence, SRB was found to be an appropriate reference tracer to mimic the behavior of mobile pesticides (low KOC, without degradation) in wetland systems and the obtained wetland characteristics for SRB may serve as an indication for contaminant retention. Owing to the properties of IPU, the obtained results should be treated as worst case scenarios for highly mobile pesticides. A comparison of six different wetland types suggested that non-steady wetland systems with large variation in water level may temporally store relatively large amounts of tracers (contaminants), partly in areas that are not continuously saturated. This may lead to an efficient attenuation of peak concentrations. However, when large parts of these systems are flushed by natural storm events, tracers (contaminants) may be re-mobilized. In steady systems vegetation density and water depth were found to be the most important factors for tracer/contaminant retention. Illustrated by SRB, sorption on sediments and vegetation was a quick, almost instantaneous process which lead to considerable tracer losses even at high flow velocities and short contact times. Shallow systems with dense vegetation appeared to be the

  11. Using the Aerasense NanoTracer for simultaneously obtaining several ultrafine particle exposure metrics

    International Nuclear Information System (INIS)

    Marra, J

    2011-01-01

    The expanding production and use of nanomaterials increases the chance of human exposure to engineered nanoparticles (NP), also referred to as ultrafine particles (UFP; ≤ 100 - 300 nm). This is particularly true in workplaces where they can become airborne and thereafter inhaled by workers during nanopowder processing. Considering the suspected hazard of many engineered UFPs, the general recommendation is to take measures for minimizing personal exposure while monitoring the UFP pollution for assessment and control purposes. The portable Aerasense NanoTracer accomplishes this UFP monitoring, either intermittently or in real time. This paper reviews its design and operational characteristics and elaborates on a number of application extensions and constraints. The NanoTracer's output signals enable several UFP exposure metrics to be simultaneously inferred. These include the airborne UFP number concentration and the number-averaged particle size, serving as characteristics of the pertaining UFP pollution. When non-hygroscopic particles are involved, the NanoTracer's output signals also allow an estimation of the lung-deposited UFP surface area concentration and the lung-deposited UFP mass concentration. It is thereby possible to distinguish between UFP depositions in the alveolar region, the trachea-bronchial region and the head airway region, respectively, by making use of the ICRP particle deposition model.

  12. Innovative use of a microbial tracer for measuring groundwater through a fractured matrix

    International Nuclear Information System (INIS)

    Strong-Gunderson, J.M.

    1995-01-01

    Site characterization for ground water remediation activities is limited by the one's ability to visualize the complexity of the subsurface environment. Currently, a variety of dyes, colloids, gases, etc., are used to monitor and estimate ground water flow and contaminant transport. The author has recently identified a new, innovative colloidal tracer that is a non-hazardous bacterium that is detectable at very low concentrations (ng/kg), and can provide real-time analysis (3--5 min) for measuring colloid transport. The tracer is the ice nucleating active (INA) bacterium Pseudomonas syringae. The assay conditions require measuring the freezing point of the sample (e.g., ground water and soil slurries). Typically, 10--100 microL drops of water will not freeze until -15 to -20 C. However, if the tracer is present the water will freeze at -3 to -7 C. This increase in the freezing point can only be due to the presence of the tracer and this phenomenon is well documented in the plant pathology and low-temperature biology literature but has only now been applied to site characterization and remediation activities. Laboratory experiments have identified the stability of the tracer in the presence of a variety of ground water contaminants (> 100 ppm) and it is stable over a pH range of 2.3--10.0. The tracer has been demonstrated in conjunction with other commonly used tracers at a variety of field sites: (1) a drilling tracer to identify potential cross contamination, and as a colloid/bacterial tracer in (2) a hydrofracturing demonstration, (3) a horizontal recirculation well system, (4) a fractured karst matrix, and (5) a radioactive contaminated site. The data from these demonstrations have provided additional information about site characteristics including faster ground water flow rates than previously identified and due to its low sensitivities better distribution into a clay matrix than estimated by the bromide tracer

  13. Simulation and interpretation of inter-well tracer tests

    Directory of Open Access Journals (Sweden)

    Dugstad Øyvind

    2013-05-01

    Full Text Available In inter-well tracer tests (IWTT, chemical compounds or radioactive isotopes are used to label injection water and gas to establish well connections and fluid patterns in petroleum reservoirs. Tracer simulation is an invaluable tool to ease the interpretation of IWTT results and is also required for assisted history matching application of tracer data. In this paper we present a new simulation technique to analyse and interpret tracer results. Laboratory results are used to establish and test formulations of the tracer conservation equations, and the technique is used to provide simulated tracer responses that are compared with observed tracer data from an extensive tracer program. The implemented tracer simulation methodology use a fast post-processing of previously simulated reservoir simulation runs. This provides a fast, flexible and powerful method for analysing gas tracer behaviour in reservoirs. We show that simulation time for tracers can be reduced by factor 100 compared to solving the tracer flow equations simultaneously with the reservoir fluid flow equations. The post-processing technique, combined with a flexible built-in local tracer-grid refinement is exploited to reduce numerical smearing, particularly severe for narrow tracer pulses.

  14. Xanthine tracers and their preparation

    International Nuclear Information System (INIS)

    Groman, E.V.; Cabelli, M.D.

    1980-01-01

    Compounds useful as tracers in the radioimmunoassay of xanthine derivatives such as theophylline and pharmacologically related drugs are described. They are substituted xanthines in which at least one substituted radical contains radioiodine. The tracers are made by linking radioiodinatable or preradioiodinated radicals to the xanthine derivative which is to be assayed. The tracers may be employed in known radioimmunoassay techniques. (author)

  15. MAK and BAT values list 2015. Maximum permissible concentrations at the place of work and biological tolerance values for working materials

    International Nuclear Information System (INIS)

    2015-01-01

    The book on the MAK (maximum permissible concentrations at the place of work) and BAT (biological tolerance values for working materials) value list 2015 includes the following chapters: (a) Maximum permissible concentrations at the place of work: definition, application and determination of MAT values, list of materials; carcinogenic working materials, sensibilizing working materials, aerosols, limiting the exposition peaks, skin resorption, MAK values during pregnancy, germ cell mutagens, specific working materials; (b) Biological tolerance values for working materials: definition and application of BAT values, list of materials, carcinogenic working materials, biological guide values, biological working material reference values.

  16. MAK and BAT values list 2014. Maximum permissible concentrations at the place of work and biological tolerance values for working materials

    International Nuclear Information System (INIS)

    2014-01-01

    The book on the MAK (maximum permissible concentrations at the place of work) and BAT (biological tolerance values for working materials) value list 2014 includes the following chapters: (a) Maximum permissible concentrations at the place of work: definition, application and determination of MAT values, list of materials; carcinogenic working materials, sensibilizing working materials, aerosols, limiting the exposition peaks, skin resorption, MAK values during pregnancy, germ cell mutagens, specific working materials; (b) Biological tolerance values for working materials: definition and application of BAT values, list of materials, carcinogenic working materials, biological guide values, biological working material reference values.

  17. Effects of crude oil on water and tracer movement in the unsaturated and saturated zones.

    Science.gov (United States)

    Delin, Geoffrey N; Herkelrath, William N

    2017-05-01

    A tracer test was conducted to aid in the investigation of water movement and solute transport at a crude-oil spill site near Bemidji, Minnesota. Time of travel was measured using breakthrough curves for rhodamine WT and bromide tracers moving from the soil surface through oil-contaminated and oil-free unsaturated zones to the saturated zone. Results indicate that the rates of tracer movement were similar in the oil-free unsaturated and saturated zones compared to the oily zones. These results are somewhat surprising given the oil contamination in the unsaturated and saturated zones. Rhodamine tracer breakthrough in the unsaturated and saturated zones in general was delayed in comparison to bromide tracer breakthrough. Peak tracer concentrations for the lysimeters and wells in the oily zone were much greater than at the corresponding depths in the oil-free zone. Water and tracer movement in the oily zone was complicated by soil hydrophobicity and decreased oil saturations toward the periphery of the oil. Preferential flow resulted in reduced tracer interaction with the soil, adsorption, and dispersion and faster tracer movement in the oily zone than expected. Tracers were freely transported through the oily zone to the water table. Recharge calculations support the idea that the oil does not substantially affect recharge in the oily zone. This is an important result indicating that previous model-based assumptions of decreased recharge beneath the oil were incorrect. Results have important implications for modeling the fate and transport of dissolved contaminants at hydrocarbon spill sites. Published by Elsevier B.V.

  18. Behavior of water of crystallization in CuSO4·5H2O studied by the tritium tracer method

    International Nuclear Information System (INIS)

    Sato, Tetsuya; Jiao, Yurong; Imaizumi, Hiroshi; Kano, Naoki

    2011-01-01

    Tritium (T) is one of hydrogen isotopes, and its chemical behavior is similar to other hydrogen isotopes. Therefore tritium is used as one of tracers in chemical experimental tracer. As one of applications, we tried to apply this method to clarifying the behavior of water of crystallization in an inorganic material. The sample used was copper sulfate pentahydrate. First, this compound was tritiated, then desorbed the water of crystallization from the tritiated compound. Comparing the behavior of amount of substance with the specific activity, the following four matters have been found. (1) There is no relation between each T concentration of HTO water and the mass of the compound within the T concentration used. (2) It can be confirmed that copper sulfate pentahydrate has three kinds of energetically different water of crystallization by T tracer method. (3) Each T concentration of water of crystallization is different at the coordinate position, and the HTO molecule is hard to coordinate at the position having weak binding force. (4) The T tracer method is useful to analyze the behavior of the combined water in materials. (author)

  19. A tracer investigation of the atmospheric dispersion in the Dyrnaes Valley, Greenland

    International Nuclear Information System (INIS)

    Gryning, S.-E.; Lyck, E.

    1983-02-01

    Mining at Kvanefjeld, Greenland, will result in releases of air pollution gases. In order to measure the dilution of these gases tracer experiments were carried out in July-August 1981. Results from these experiments are described. The Kvanefjeld constitutes the northwestern side of a valley. The tracer was released at the Kvanefjeld during the night and sampled in the valley. The measured tracer concentrations were compared with those calculated by use of a conventional model of the dispersion of plumes. The dilution of the tracer was found to correspond to the dilution at ground level of a plume from a stack of 100-200 m height in atmospheric neutral conditions (wind speed 5 m/s). General aspects of the flow-field in the valley are discussed. It was observed that the flow direction in the valley shifts between downvalley and upvalley with a period of approximately 1 hour. It is suggested that this behaviour is caused by the interplay of a drainage flow and a sea-breeze. (author)

  20. New developments in the use of stable activable tracers in environmental science

    International Nuclear Information System (INIS)

    Loveland, W.; Keasler, K.; Ghannam, L.; Borovik, A.

    1980-01-01

    Recent developments in the use of stable activable tracers (SATs) in environmental science are reported. (A stable activable tracer is a stable material injected into a system under study and whose concentration is measured by post-sampling activation analysis.) The activable nuclear parts of the tracers studied have been rare earth nuclides with short-lived activation products or Cu. To trace the fate of fluid-bound pollutants (and/or water masses) in marine waters, we have used anionic DTPA complexes of the rare earths. These tracers were shown to be stable (80 to 90% nondissociated) in extensive laboratory tests involving solutions of the tracer in estuarine water including large amounts of marine sediments. Results of a field study in which the flushing time and other hydrological characteristics of an estuarine marina were measured by simultaneously using a fluorescent dye and a SAT are presented. To trace the path of potentially toxic organic molecules, three stable activable tracers, dysprosium(III)-trisacetylacetonate DY(acac) 3 3H 2 O), dysprosium(III)-trisdibenzoylmethane (DY(dbm) 3 H 2 O and copper oxinate Cu (C 9 H 6 ON) 2 were synthesized. Their octanol/water partition coefficients and their solubility in water were measured and used to correlate the tracer species and its biological activity with that of known toxic materials. In a project to demonstrate the simple use of SATs to trace the origin of common insecticides and herbicides, seven common insecticides and herbicides were marked with anionic rare earth DTPA complexes and shown to be detectable at dilutions of 1 part in 10 12 . Two arsenical herbicides were chosen for further study and the tracer/herbicide ratio was shown to remain constant in samples of herbicide material collected on plant surfaces and runoff waters in the environment for long periods

  1. Combined interpretation of radar, hydraulic, and tracer data from a fractured-rock aquifer near Mirror Lake, New Hampshire, USA

    Science.gov (United States)

    Day-Lewis, F. D.; Lane, J.W.; Gorelick, S.M.

    2006-01-01

    An integrated interpretation of field experimental cross-hole radar, tracer, and hydraulic data demonstrates the value of combining time-lapse geophysical monitoring with conventional hydrologic measurements for improved characterization of a fractured-rock aquifer. Time-lapse difference-attenuation radar tomography was conducted during saline tracer experiments at the US Geological Survey Fractured Rock Hydrology Research Site near Mirror Lake, Grafton County, New Hampshire, USA. The presence of electrically conductive saline tracer effectively illuminates permeable fractures or pathways for geophysical imaging. The geophysical results guide the construction of three-dimensional numerical models of ground-water flow and solute transport. In an effort to explore alternative explanations for the tracer and tomographic data, a suite of conceptual models involving heterogeneous hydraulic conductivity fields and rate-limited mass transfer are considered. Calibration data include tracer concentrations, the arrival time of peak concentration at the outlet, and steady-state hydraulic head. Results from the coupled inversion procedure suggest that much of the tracer mass migrated outside the three tomographic image planes, and that solute is likely transported by two pathways through the system. This work provides basic and site-specific insights into the control of permeability heterogeneity on ground-water flow and solute transport in fractured rock. ?? Springer-Verlag 2004.

  2. Addition of tracers into the polypropylene in view of automatic sorting of plastic wastes using X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Bezati, F.; Froelich, D.; Massardier, V.; Maris, E.

    2010-01-01

    This study focused on the detection of rare earth oxides, used as tracers for the identification of polymer materials, using XRF (X-ray fluorescence) spectrometry. The tests were carried out in a test system device which allows the collection of static measurements of the samples' spectrum through the use of energy dispersive X-ray fluorescence technology. A sorting process based on tracers added into the polymer matrix is proposed in order to increase sorting selectivity of polypropylene during end-of-life recycling. Tracers consist of systems formed by one or by several substances dispersed into a material, to add a selective property to it, with the aim of improving the efficiency of sorting and high speed identification. Several samples containing rare earth oxides (Y 2 O 3 , CeO 2 , Nd 2 O 3 , Gd 2 O 3 , Dy 2 O 3 , Er 2 O 3 and Yb 2 O 3 ) in different concentrations were prepared in order to analyse some of the parameters which can influence the detection, such as the concentration of tracers, the acquisition time and the possible overlapping among the tracers. This work shows that by using the XRF test system device, it was possible to detect 5 of the 7 tracers tested for 1 min exposure time and at a concentration level of 1000 ppm. These two parameters will play an important role in the development of an industrial device, which indicates the necessity of further works that needs to be conducted in order to reduce them.

  3. Benefits of the maximum tolerated dose (MTD) and maximum tolerated concentration (MTC) concept in aquatic toxicology

    International Nuclear Information System (INIS)

    Hutchinson, Thomas H.; Boegi, Christian; Winter, Matthew J.; Owens, J. Willie

    2009-01-01

    development of sound criteria for data interpretation when the exposure of organisms has exceeded the MTD. While the MTD approach is well established for oral, topical, inhalational or injection exposure routes in mammalian toxicology, we propose that for exposure of aquatic organisms via immersion, the term Maximum Tolerated Concentration (MTC) is more appropriate

  4. Isotopic marking and tracers

    International Nuclear Information System (INIS)

    Morel, F.

    1997-01-01

    The use of radioactive isotopes as tracers in biology has been developed thanks to the economic generation of the required isotopes in accelerators and nuclear reactors, and to the multiple applications of tracers in the life domain; the most usual isotopes employed in biology are carbon, hydrogen, phosphorus and sulfur isotopes, because these elements are present in most of organic molecules. Most of the life science knowledge appears to be dependent to the extensive use of nuclear tools and radioactive tracers; the example of the utilization of radioactive phosphorus marked ATP to study the multiple reactions with proteins, nucleic acids, etc., is given

  5. Interpretation of the tracer testing conducted in the Leuggern borehole

    International Nuclear Information System (INIS)

    McNeish, J.A.; Andrews, R.W.; Vomvoris, S.

    1990-12-01

    Tracer testing was conducted in the Leuggern borehole from July to December 1988 to evaluate the hydraulic properties of the crystalline host rock. The tested interval was an approximately 50 m section of fractured crystalline rock at a depth of greater than 1,600 m. The testing consisted of three tracer injection/recovery periods (uranin - 44 days, eosin - 30 days, and naphtionat -14 days), which utilized tracer injection/circulation rates, ranging between 25 and 50 ml/min. During these testing periods, tracer was injected in either of two 1/4 flow lines ported at the top or bottom of the interval and recovered from the other. Following the three tracer injection periods, a natural outflow tracer recovery test was conducted from the central tubing at an average outflow of 12 l/min. The central tubing was ported near the center of the test interval. Data collected during the testing periods included: continuous monitoring of fluid temperature, injection pressure, and electrical conductivity as well as discrete measurement of flow rates, electrical conductivity, fluid temperature, and tracer concentration. Testing results indicate a downward vertical flow of approximately 195-225 ml/min in the isolated interval, from an upper fracture inflow zone to a lower fracture outflow zone. Through analysis of the dilution levels of uranin and eosin during the injection/recovery periods, and review of field data, the top of the upper inflow zone was determined to be approximately 13 m below the top flow line and the bottom of the outflow zone to be approximately 3 to 5 meters above the bottom flow line. The calculated transmissivity value of 6E-05 m 2 /s from observed outflow rate and pressure recovery data, is consistent with results derived from previous hydraulic packer testing in the interval. The effective porosity was determined to be 0.1. Dispersion coefficient values ranged from 1.0 m to 5.0 m. The lateral hydraulic gradient value calculated from tracer recovery

  6. How well do different tracers constrain the firn diffusivity profile?

    Directory of Open Access Journals (Sweden)

    C. M. Trudinger

    2013-02-01

    Full Text Available Firn air transport models are used to interpret measurements of the composition of air in firn and bubbles trapped in ice in order to reconstruct past atmospheric composition. The diffusivity profile in the firn is usually calibrated by comparing modelled and measured concentrations for tracers with known atmospheric history. However, in most cases this is an under-determined inverse problem, often with multiple solutions giving an adequate fit to the data (this is known as equifinality. Here we describe a method to estimate the firn diffusivity profile that allows multiple solutions to be identified, in order to quantify the uncertainty in diffusivity due to equifinality. We then look at how well different combinations of tracers constrain the firn diffusivity profile. Tracers with rapid atmospheric variations like CH3CCl3, HFCs and 14CO2 are most useful for constraining molecular diffusivity, while &delta:15N2 is useful for constraining parameters related to convective mixing near the surface. When errors in the observations are small and Gaussian, three carefully selected tracers are able to constrain the molecular diffusivity profile well with minimal equifinality. However, with realistic data errors or additional processes to constrain, there is benefit to including as many tracers as possible to reduce the uncertainties. We calculate CO2 age distributions and their spectral widths with uncertainties for five firn sites (NEEM, DE08-2, DSSW20K, South Pole 1995 and South Pole 2001 with quite different characteristics and tracers available for calibration. We recommend moving away from the use of a firn model with one calibrated parameter set to infer atmospheric histories, and instead suggest using multiple parameter sets, preferably with multiple representations of uncertain processes, to assist in quantification of the uncertainties.

  7. Advection and dispersion of bed load tracers

    Science.gov (United States)

    Lajeunesse, Eric; Devauchelle, Olivier; James, François

    2018-05-01

    We use the erosion-deposition model introduced by Charru et al. (2004) to numerically simulate the evolution of a plume of bed load tracers entrained by a steady flow. In this model, the propagation of the plume results from the stochastic exchange of particles between the bed and the bed load layer. We find a transition between two asymptotic regimes. The tracers, initially at rest, are gradually set into motion by the flow. During this entrainment regime, the plume is strongly skewed in the direction of propagation and continuously accelerates while spreading nonlinearly. With time, the skewness of the plume eventually reaches a maximum value before decreasing. This marks the transition to an advection-diffusion regime in which the plume becomes increasingly symmetrical, spreads linearly, and advances at constant velocity. We analytically derive the expressions of the position, the variance, and the skewness of the plume and investigate their asymptotic regimes. Our model assumes steady state. In the field, however, bed load transport is intermittent. We show that the asymptotic regimes become insensitive to this intermittency when expressed in terms of the distance traveled by the plume. If this finding applies to the field, it might provide an estimate for the average bed load transport rate.

  8. Heat tracer test in an alluvial aquifer: Field experiment and inverse modelling

    Science.gov (United States)

    Klepikova, Maria; Wildemeersch, Samuel; Hermans, Thomas; Jamin, Pierre; Orban, Philippe; Nguyen, Frédéric; Brouyère, Serge; Dassargues, Alain

    2016-09-01

    Using heat as an active tracer for aquifer characterization is a topic of increasing interest. In this study, we investigate the potential of using heat tracer tests for characterization of a shallow alluvial aquifer. A thermal tracer test was conducted in the alluvial aquifer of the Meuse River, Belgium. The tracing experiment consisted in simultaneously injecting heated water and a dye tracer in an injection well and monitoring the evolution of groundwater temperature and tracer concentration in the pumping well and in measurement intervals. To get insights in the 3D characteristics of the heat transport mechanisms, temperature data from a large number of observation wells closely spaced along three transects were used. Temperature breakthrough curves in observation wells are contrasted with what would be expected in an ideal layered aquifer. They reveal strongly unequal lateral and vertical components of the transport mechanisms. The observed complex behavior of the heat plume is explained by the groundwater flow gradient on the site and heterogeneities in the hydraulic conductivity field. Moreover, due to high injection temperatures during the field experiment a temperature-induced fluid density effect on heat transport occurred. By using a flow and heat transport numerical model with variable density coupled with a pilot point approach for inversion of the hydraulic conductivity field, the main preferential flow paths were delineated. The successful application of a field heat tracer test at this site suggests that heat tracer tests is a promising approach to image hydraulic conductivity field. This methodology could be applied in aquifer thermal energy storage (ATES) projects for assessing future efficiency that is strongly linked to the hydraulic conductivity variability in the considered aquifer.

  9. Photoacoustic infrared spectroscopy for conducting gas tracer tests and measuring water saturations in landfills

    International Nuclear Information System (INIS)

    Jung, Yoojin; Han, Byunghyun; Mostafid, M. Erfan; Chiu, Pei; Yazdani, Ramin; Imhoff, Paul T.

    2012-01-01

    Highlights: ► Photoacoustic infrared spectroscopy tested for measuring tracer gas in landfills. ► Measurement errors for tracer gases were 1–3% in landfill gas. ► Background signals from landfill gas result in elevated limits of detection. ► Technique is much less expensive and easier to use than GC. - Abstract: Gas tracer tests can be used to determine gas flow patterns within landfills, quantify volatile contaminant residence time, and measure water within refuse. While gas chromatography (GC) has been traditionally used to analyze gas tracers in refuse, photoacoustic spectroscopy (PAS) might allow real-time measurements with reduced personnel costs and greater mobility and ease of use. Laboratory and field experiments were conducted to evaluate the efficacy of PAS for conducting gas tracer tests in landfills. Two tracer gases, difluoromethane (DFM) and sulfur hexafluoride (SF 6 ), were measured with a commercial PAS instrument. Relative measurement errors were invariant with tracer concentration but influenced by background gas: errors were 1–3% in landfill gas but 4–5% in air. Two partitioning gas tracer tests were conducted in an aerobic landfill, and limits of detection (LODs) were 3–4 times larger for DFM with PAS versus GC due to temporal changes in background signals. While higher LODs can be compensated by injecting larger tracer mass, changes in background signals increased the uncertainty in measured water saturations by up to 25% over comparable GC methods. PAS has distinct advantages over GC with respect to personnel costs and ease of use, although for field applications GC analyses of select samples are recommended to quantify instrument interferences.

  10. In situ measurement of methane oxidation in groundwater by using natural-gradient tracer tests

    International Nuclear Information System (INIS)

    Smith, R.L.; Howes, B.L.; Garabedian, S.P.

    1991-01-01

    Methane oxidation was measured in an unconfined sand and gravel aquifer (Cape Cod, Mass.) by using in situ natural-gradient tracer tests at both a pristine, oxygenated site and an anoxic, sewage-contaminated site. The tracer sites were equipped with multilevel sampling devices to create target grids of sampling points; the injectate was prepared with groundwater from the tracer site to maintain the same geochemical conditions. Methane oxidation was calculated from breakthrough curves of methane relative to halide and inert gas (hexafluoroethane) tracers and was confirmed by the appearance of 13 C-enriched carbon dioxide in experiments in which 13 C-enriched methane was used as the tracer. A V max for methane oxidation could be calculated when the methane concentration was sufficiently high to result in zero-order kinetics throughout the entire transport interval. Methane breakthrough curves could be simulated by modifying a one-dimensional advection-dispersion transport model to include a Michaelis-Menten-based consumption term for methane oxidation. The K m values for methane oxidation that gave the best match for the breakthrough curve peaks were 6.0 and 9.0 μM for the uncontaminated and contaminated sites, respectively. Natural-gradient tracer tests are a promising approach for assessing microbial processes and for testing in situ bioremediation potential in groundwater systems

  11. A comparison of muscle activity in concentric and counter movement maximum bench press.

    Science.gov (United States)

    van den Tillaar, Roland; Ettema, Gertjan

    2013-01-01

    The purpose of this study was to compare the kinematics and muscle activation patterns of regular free-weight bench press (counter movement) with pure concentric lifts in the ascending phase of a successful one repetition maximum (1-RM) attempt in the bench press. Our aim was to evaluate if diminishing potentiation could be the cause of the sticking region. Since diminishing potentiation cannot occur in pure concentric lifts, the occurrence of a sticking region in this type of muscle actions would support the hypothesis that the sticking region is due to a poor mechanical position. Eleven male participants (age 21.9 ± 1.7 yrs, body mass 80.7 ± 10.9 kg, body height 1.79 ± 0.07 m) conducted 1-RM lifts in counter movement and in pure concentric bench presses in which kinematics and EMG activity were measured. In both conditions, a sticking region occurred. However, the start of the sticking region was different between the two bench presses. In addition, in four of six muscles, the muscle activity was higher in the counter movement bench press compared to the concentric one. Considering the findings of the muscle activity of six muscles during the maximal lifts it was concluded that the diminishing effect of force potentiation, which occurs in the counter movement bench press, in combination with a delayed muscle activation unlikely explains the existence of the sticking region in a 1-RM bench press. Most likely, the sticking region is the result of a poor mechanical force position.

  12. Mapping fracture flow paths with a nanoscale zero-valent iron tracer test and a flowmeter test

    Science.gov (United States)

    Chuang, Po-Yu; Chia, Yeeping; Chiu, Yung-Chia; Teng, Mao-Hua; Liou, Sofia Ya Hsuan

    2018-02-01

    The detection of preferential flow paths and the characterization of their hydraulic properties are important for the development of hydrogeological conceptual models in fractured-rock aquifers. In this study, nanoscale zero-valent iron (nZVI) particles were used as tracers to characterize fracture connectivity between two boreholes in fractured rock. A magnet array was installed vertically in the observation well to attract arriving nZVI particles and identify the location of the incoming tracer. Heat-pulse flowmeter tests were conducted to delineate the permeable fractures in the two wells for the design of the tracer test. The nZVI slurry was released in the screened injection well. The arrival of the slurry in the observation well was detected by an increase in electrical conductivity, while the depth of the connected fracture was identified by the distribution of nZVI particles attracted to the magnet array. The position where the maximum weight of attracted nZVI particles was observed coincides with the depth of a permeable fracture zone delineated by the heat-pulse flowmeter. In addition, a saline tracer test produced comparable results with the nZVI tracer test. Numerical simulation was performed using MODFLOW with MT3DMS to estimate the hydraulic properties of the connected fracture zones between the two wells. The study results indicate that the nZVI particle could be a promising tracer for the characterization of flow paths in fractured rock.

  13. Verification of mid-ocean ballast water exchange using naturally occurring coastal tracers

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, Kathleen; Boehme, Jennifer; Coble, Paula; Cullen, Jay; Field, Paul; Moore, Willard; Perry, Elgin; Sherrell, Robert; Ruiz, Gregory

    2004-04-01

    We examined methods for verifying whether or not ships have performed mid-ocean ballast water exchange (BWE) on four commercial vessels operating in the Pacific and Atlantic Oceans. During BWE, a ship replaces the coastal water in its ballast tanks with water drawn from the open ocean, which is considered to harbor fewer organisms capable of establishing in coastal environments. We measured concentrations of several naturally occurring chemical tracers (salinity, six trace elements, colored dissolved organic matter fluorescence and radium isotopes) along ocean transects and in ballast tanks subjected to varying degrees of BWE (0-99%). Many coastal tracers showed significant concentration changes due to BWE, and our ability to detect differences between exchanged and unexchanged ballast tanks was greatest under multivariate analysis. An expanded dataset, which includes additional geographic regions, is now needed to test the generality of our results.

  14. Verification of mid-ocean ballast water exchange using naturally occurring coastal tracers

    International Nuclear Information System (INIS)

    Murphy, Kathleen; Boehme, Jennifer; Coble, Paula; Cullen, Jay; Field, Paul; Moore, Willard; Perry, Elgin; Sherrell, Robert; Ruiz, Gregory

    2004-01-01

    We examined methods for verifying whether or not ships have performed mid-ocean ballast water exchange (BWE) on four commercial vessels operating in the Pacific and Atlantic Oceans. During BWE, a ship replaces the coastal water in its ballast tanks with water drawn from the open ocean, which is considered to harbor fewer organisms capable of establishing in coastal environments. We measured concentrations of several naturally occurring chemical tracers (salinity, six trace elements, colored dissolved organic matter fluorescence and radium isotopes) along ocean transects and in ballast tanks subjected to varying degrees of BWE (0-99%). Many coastal tracers showed significant concentration changes due to BWE, and our ability to detect differences between exchanged and unexchanged ballast tanks was greatest under multivariate analysis. An expanded dataset, which includes additional geographic regions, is now needed to test the generality of our results

  15. Intracellular performance of tailored nanoparticle tracers in magnetic particle imaging

    Energy Technology Data Exchange (ETDEWEB)

    Arami, Hamed; Krishnan, Kannan M., E-mail: kannanmk@uw.edu [Department of Materials Science and Engineering, University of Washington, P.O. Box 352120, Seattle, Washington 98195-2120 (United States)

    2014-05-07

    Magnetic Particle Imaging (MPI) is a quantitative mass-sensitive, tracer-based imaging technique, with potential applications in various cellular imaging applications. The spatial resolution of MPI, in the first approximation, improves by decreasing the full width at half maximum (FWHM) of the field-derivative of the magnetization, dm/dH of the nanoparticle (NP) tracers. The FWHM of dm/dH depends critically on NPs’ size, size distribution, and their environment. However, there is limited information on the MPI performance of the NPs after their internalization into cells. In this work, 30 to 150 μg of the iron oxide NPs were incubated in a lysosome-like acidic buffer (0.2 ml, 20 mM citric acid, pH 4.7) and investigated by vibrating sample magnetometry, magnetic particle spectroscopy, transmission electron microscopy, and dynamic light scattering (DLS). The FWHM of the dm/dH curves of the NPs increased with incubation time and buffer to NPs ratio, consistent with a decrease in the median core size of the NPs from ∼20.1 ± 0.98 to ∼18.5 ± 3.15 nm. Further, these smaller degraded NPs formed aggregates that responded to the applied field by hysteretic reversal at higher field values and increased the FWHM. The rate of core size decrease and aggregation were inversely proportional to the concentration of the incubated NPs, due to their slower biodegradation kinetics. The results of this model experiment show that the MPI performance of the NPs in the acidic environments of the intracellular organelles (i.e., lysosomes and endosomes) can be highly dependent on their rate of internalization, residence time, and degradation.

  16. Bromide as a tracer for studying water movement and nitrate displacement in soils: comparison with stable isotope tracers

    International Nuclear Information System (INIS)

    Russow, R.; Knappe, S.

    1999-01-01

    Tracers are an ideal means of studying water movement and associated nitrate displacement. Often bromide is preferred as a tracer because it is considered a representative tracer for water and because, being a conservative tracer (i.e. not involved in chemical and biological soil processes), it can be used for studying anion transport in soils. Moreover, it is less expensive and easier to measure than the stable isotopes deuterium and 15 N. Its great advantage over radioactive tracers (e.g. tritium), which outweighs their extreme sensitivity and ease of measurement and which it has in common with stable isotopes, is that it does not require radiation protection measures. However, there are also constraints on the use of bromide as a tracer in soil/water/plant systems. Our own studies on different soils using D 2 O, bromide and [ 15 N]-nitrate in lysimeters suggest that the above assumptions on bromide tracers need not always be valid under conditions as they prevail in biologically active soils. As the present paper shows, these studies permit a good assessment of the possibilities and limits to these tracers [de

  17. Measurement of open streams by using tracers

    International Nuclear Information System (INIS)

    Ramos, German F.; Tarquino, W.; Curcuy, H.; Orozco, C.

    1999-01-01

    This paper presents an intercomparison study to be carried out between flux measurements by using tracers and moulinet. This intercomparison is scheduled to be performed at the measurement station belonging to the National Service of Meteorology and Hydrology (SENAMHI). Two techniques of tracer dilution are outstanded: total evaluation with tracer punctual injection and punctual evaluation with tracer continuous injection. Total evaluation with tracer punctual injection has been used since this technique is considered to be more suitable for hydrology purposes

  18. A comparison of resting images from two myocardial perfusion tracers

    International Nuclear Information System (INIS)

    Anagnostopoulos, C.; Laney, R.; Pennell, D.; Proukakis, H.; Underwood, R.

    1995-01-01

    We have compared stress-redistribution and delayed rest thallium-201 with rest technetium-99m methoxyisobutylisonitrile (MIBI) tomograms in order to compare the tracers for the assessment of myocardial viability and to validate a rapid protocol combining the two tracers. We studied 30 consecutive patients with known or suspected coronary artery disease [group 1: 16 with normal left ventricular function, mean left ventricular ejection fraction (LVEF) 55%, SD 6%; group 2: 14 with abnormal function, mean LVEF 28%, SD 8%]. 201 Tl was injected during infusion of adenosine followed by acquisition of conventional stress and redistribution tomograms. On a separate day, 201 Tl was injected at rest with imaging 4 h later. 99m Tc-MIBI was then given at rest and imaging was performed. Three images were compared: redistribution 201 Tl, rest 201 Tl, and rest 99m Tc-MIBI. Tracer activity was classified visually and quantitatively in nine segments and segments with>50% activity were defined as containing clinically significant viable myocardium. Mean global tracer uptake as a percentage of maximum was similar in group 1 (rest 201 Tl 69%±12%, redistribution 201 Tl 69%±15%, rest 99m Tc-MIBI 70%±13%), but in group 2 mean tracer uptake was significantly greater in the rest 201 Tl images (59%±16%) than in redistribution 201 Tl images (53%±17%) or rest 99m Tc-MIBI images (53%±19%). Overall agreement for regional uptake score was excellent (κ from 0.79 to 0.84), although there were a significant number of segments with less uptake shown by redistribution 201 Tl and by rest 99m Tc-MIBI than by rest 201 Tl in group 2. The number of segments with significant viable myocardium in group 1 was very similar between the three images but in group 2 rest 201 Tl identified significantly more segments as viable than the other images. (orig./MG) (orig.). With 1 fig., 7 tabs

  19. Tracer attenuation in groundwater

    Science.gov (United States)

    Cvetkovic, Vladimir

    2011-12-01

    The self-purifying capacity of aquifers strongly depends on the attenuation of waterborne contaminants, i.e., irreversible loss of contaminant mass on a given scale as a result of coupled transport and transformation processes. A general formulation of tracer attenuation in groundwater is presented. Basic sensitivities of attenuation to macrodispersion and retention are illustrated for a few typical retention mechanisms. Tracer recovery is suggested as an experimental proxy for attenuation. Unique experimental data of tracer recovery in crystalline rock compare favorably with the theoretical model that is based on diffusion-controlled retention. Non-Fickian hydrodynamic transport has potentially a large impact on field-scale attenuation of dissolved contaminants.

  20. Synthesis of isotopically modified ZnO nanoparticles and their potential as nanotoxicity tracers.

    Science.gov (United States)

    Dybowska, Agnieszka D; Croteau, Marie-Noele; Misra, Superb K; Berhanu, Deborah; Luoma, Samuel N; Christian, Paul; O'Brien, Paul; Valsami-Jones, Eugenia

    2011-01-01

    Understanding the behavior of engineered nanoparticles in the environment and within organisms is perhaps the biggest obstacle to the safe development of nanotechnologies. Reliable tracing is a particular issue for nanoparticles such as ZnO, because Zn is an essential element and a common pollutant thus present at elevated background concentrations. We synthesized isotopically enriched (89.6%) with a rare isotope of Zn (67Zn) ZnO nanoparticles and measured the uptake of 67Zn by L. stagnalis exposed to diatoms amended with the particles. Stable isotope technique is sufficiently sensitive to determine the uptake of Zn at an exposure equivalent to lower concentration range (<15 μg g(-1)). Without a tracer, detection of newly accumulated Zn is significant at Zn exposure concentration only above 5000 μg g(-1) which represents some of the most contaminated Zn conditions. Only by using a tracer we can study Zn uptake at a range of environmentally realistic exposure conditions. Copyright © 2010 Elsevier Ltd. All rights reserved.

  1. Synthesis of isotopically modified ZnO nanoparticles and their potential as nanotoxicity tracers

    Science.gov (United States)

    Dybowska, A.D.; Croteau, M.-N.; Misra, S.K.; Berhanu, D.; Luoma, S.N.; Christian, P.; O'Brien, P.; Valsami-Jones, E.

    2011-01-01

    Understanding the behavior of engineered nanoparticles in the environment and within organisms is perhaps the biggest obstacle to the safe development of nanotechnologies. Reliable tracing is a particular issue for nanoparticles such as ZnO, because Zn is an essential element and a common pollutant thus present at elevated background concentrations. We synthesized isotopically enriched (89.6%) with a rare isotope of Zn (67Zn) ZnO nanoparticles and measured the uptake of 67Zn by L. stagnalis exposed to diatoms amended with the particles. Stable isotope technique is sufficiently sensitive to determine the uptake of Zn at an exposure equivalent to lower concentration range (<15 ??g g-1). Without a tracer, detection of newly accumulated Zn is significant at Zn exposure concentration only above 5000 ??g g-1 which represents some of the most contaminated Zn conditions. Only by using a tracer we can study Zn uptake at a range of environmentally realistic exposure conditions. ?? 2010 Elsevier Ltd. All rights reserved.

  2. Determining Near-Bottom Fluxes of Passive Tracers in Aquatic Environments

    Science.gov (United States)

    Bluteau, Cynthia E.; Ivey, Gregory N.; Donis, Daphne; McGinnis, Daniel F.

    2018-03-01

    In aquatic systems, the eddy correlation method (ECM) provides vertical flux measurements near the sediment-water interface. The ECM independently measures the turbulent vertical velocities w' and the turbulent tracer concentration c' at a high sampling rate (> 1 Hz) to obtain the vertical flux w'c'¯ from their time-averaged covariance. This method requires identifying and resolving all the flow-dependent time (and length) scales contributing to w'c'¯. With increasingly energetic flows, we demonstrate that the ECM's current technology precludes resolving the smallest flux-contributing scales. To avoid these difficulties, we show that for passive tracers such as dissolved oxygen, w'c'¯ can be measured from estimates of two scalar quantities: the rate of turbulent kinetic energy dissipation ɛ and the rate of tracer variance dissipation χc. Applying this approach to both laboratory and field observations demonstrates that w'c'¯ is well resolved by the new method and can provide flux estimates in more energetic flows where the ECM cannot be used.

  3. Dual Tracer PET Imaging with FDG and FLT Differentiates Tuberculous Lymphadenopathy from Metastases in a Case of Carcinoma Cervix

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Prathamesh; Lele, Vikram; Aland, Parag; Gemawat, Shilpa [Jaslok Hospital and Research Centre, Woril (India)

    2013-09-15

    infective/inflammatory pathology was raised in the final report. Considering maximum metabolic activity on FDG PET and feasibility, open biopsy of right axillary lymph node was performed; which revealed tuberculosis. Patient was started on anti-tuberculosis therapy and she reported gradual weight gain with no new symptoms over last 3 months. Though extensively used for evaluation of malignancies, FDG is not a cancer-specific tracer. Non-specific uptake is often seen in active macrophages in infective and inflammatory pathologies. Hence, a tracer that is more specific marker for malignancy can help to identify false-positive FDG PET findings. Use of dual tracer imaging with FDG and FLT to differentiate between benign and malignant lesions has been described in the literature for characterization of pulmonary lesions. FLT is thought to be relatively more specific compared to 18F-FDG, in that it is a cell proliferation tracer; FLT usually does not concentrate in benign lesions. Our case demonstrates the usefulness of a dual tracer imaging approach to identify benign cause of FDG avid lymphadenopathy in a known case of malignancy. This approach may play a vital role.

  4. Atmospheric tracer experiments for regional dispersion studies

    International Nuclear Information System (INIS)

    Heffter, J.L.; Ferber, G.J.

    1980-01-01

    Tracer experiments are being conducted to verify atmospheric transport and dispersion calculations at distances from tens to hundreds of km from pollutant sources. In one study, a 2 1/2 year sampling program has been carried out at 13 sites located 30 to 140 km from a source of 85 Kr at the Savannah River Plant in South Carolina. Average weekly concentrations as well as twice-daily concentrations were obtained. Sampling data and meteorological data, including surface, tower, and rawinsonde observations are available on magnetic tape for model verification studies. Some verification results for the Air Resources Laboratories Atmospheric Transort and Dispersion Model (ARL-ATAD) are shown for averaging periods from one week to two years

  5. USE OF PERFLUOROCARBON TRACER (PFT) TECHNOLOGY FOR SUBSURFACE BARRIER INTEGRITY VERIFICATION AT THE WALDO TEST SITE

    Energy Technology Data Exchange (ETDEWEB)

    SULLIVAN,T.; HEISER,J.; SENUM,G.; MILLIAN,L.

    2000-02-27

    Researchers from Brookhaven National Laboratory (BNL) tested perfluorocarbon (PFT) gas tracers on a subsurface barrier with known flaws at the Waldo test facility [operated by Science and Engineering Associates, Inc (SEA)]. The tests involved the use of five unique PFT tracers with a different tracer injected along the interior of each wall of the barrier. A fifth tracer was injected exterior to the barrier to examine the validity of diffusion controlled transport of the PFTs. The PFTs were injected for three days at a nominal flow rate of 15 cm{sup 3}/min and a concentrations in the range of a few hundred ppm. Approximately 65 liters of air laced with tracer was injected for each tracer. The tracers were able to accurately detect the presence of the engineered flaws. Two flaws were detected on the north and east walls and lane flaw was detected on the south and west walls. In addition, one non-engineered flaw at the seam between the north and east walls was also detected. The use of multiple tracers provided independent confirmation of the flaws and permitted a distinction between tracers arriving at a monitoring port after being released from a nearby flaw and non-engineered flaws. The PFTs detected the smallest flaw, 0.5 inches in diameter. Visual inspection of the data showed excellent agreement with the known flaw locations and the relative size of the flaws was accurately estimated.

  6. Modelling and tracer studies of atmospheric dispersion and deposition in regions of complex topography

    International Nuclear Information System (INIS)

    Norden, C.E.

    1981-11-01

    An indium tracer aerosol generating apparatus based on an alcohol/oxygen burner, and an analytical procedure by which filter samples containing tracer material could be analysed quantitatively by means of neutron activation analysis, were developed for use in atmospheric dispersion and deposition studies. A number of series of atmospheric dispersion experiments were conducted in the Richards Bay and Koeberg- Cape Town areas. The results are given, comparing the airbone tracer concentrations measured at ground level with values predicted by means of a numerical model, utilising two to three schemes, varying in sophistication, for calculating the dispersion coefficients. Recommendations are given regarding a dispersion model and dispersion coefficients for regular use in the Koeberg area, and ways for estimating plume trajectories

  7. Heavy methanes (mass-20 and -21) as atmospheric tracers. A new research initiatives project

    International Nuclear Information System (INIS)

    Guthals, P.R.; Fowler, M.M.

    1978-07-01

    Products from the stable isotope production project (ICONS) at the Los Alamos Scientific Laboratory (LASL) have had applications in a number of practical problems. Fully deuterated methanes, using 12 C and 13 C (mass-20 and -21, respectively), are detectable in the atmosphere at very low concentrations. The detection limits are due to an almost zero background and a distinct mass-spectrometric line. These properties, coupled with long lifetimes in the atmosphere, make the heavy methanes strong candidates for tracers of atmospheric transport and turbulence on regional to global scales. Three field tests have been conducted to assess the feasibility and to demonstrate the desirable properties of heavy methanes as atmospheric tracers. In the first test in May 1974, heavy methane released at the Idaho National Engineering Laboratory (INEL) was sampled and detected in several midwestern cities up to 2500 km downstream. These results agree with trajectories estimated from observed meteorological data. A second experiment, conducted in December 1975 at the Savannah River Plant, compared two heavy methanes with SF 6 and 85 Kr over a transport distance of 100 km. Increased detail in meteorological support data and ground-level sampling offered options of data interpretation unavailable in the first test. Qualitative patterns of tracer concentrations show good agreement among the four tracers and are verified by the meteorological inputs. The third experiment, performed in April 1977 at INEL, built on the experience of the previous two. Detailed ground-level sampling arrays at 3, 50, and 90 km from the release point were supplemented by aircraft and a crude sampling line across the Continental Divide at 300-km distance. Two new perfluorocarbon tracers were included for comparison

  8. Conceptualisation of Snowpack Isotope Dynamics in Spatially Distributed Tracer-Aided Runoff Models in Snow Influenced Northern Cathments

    Science.gov (United States)

    Ala-aho, P. O. A.; Tetzlaff, D.; Laudon, H.; McNamara, J. P.; Soulsby, C.

    2016-12-01

    We use the Spatially distributed Tracer-Aided Rainfall-Runoff (STARR) modelling framework to explore non-stationary flow and isotope response in three northern headwater catchments. The model simulates dynamic, spatially variable tracer concentration in different water stores and fluxes within a catchment, which can constrain internal catchment mixing processes, flow paths and associated water ages. To date, a major limitation in using such models in snow-dominated catchments has been the difficulties in paramaterising the isotopic transformations in snowpack accumulation and melt. We use high quality long term datasets for hydrometrics and stable water isotopes collected in three northern study catchments for model calibration and testing. The three catchments exhibit different hydroclimatic conditions, soil and vegetation types, and topographic relief, which brings about variable degree of snow dominance across the catchments. To account for the snow influence we develop novel formulations to estimate the isotope evolution in the snowpack and melt. Algorithms for the isotopic evolution parameterize an isotopic offset between snow evaporation and melt fluxes and the remaining snow storage. The model for each catchment is calibrated to match both streamflow and tracer concentration at the stream outlet to ensure internal consistency of the system behaviour. The model is able to reproduce the streamflow along with the spatio-temporal differences in tracer concentrations across the three studies catchments reasonably well. Incorporating the spatially distributed snowmelt processes and associated isotope transformations proved essential in capturing the stream tracer reponse for strongly snow-influenced cathments. This provides a transferrable tool which can be used to understand spatio-temporal variability of mixing and water ages for different storages and flow paths in other snow influenced, environments.

  9. Wairakei tracer tests 1983

    International Nuclear Information System (INIS)

    McCabe, W.J.; Barry, B.J.

    1984-05-01

    Tracer tests, with and without, hot water reinjection into WK213 showed returns of tracer iodine-131; in wells in both the Waiora Valley and the eastern end of the field. The effect of reinjection at a rate of 200 cu. m/h was to reduce the arrived time from 15 to 7 days. Increasing the rate of reinjection into WK62 from 30 cu. m/h to 200 cu. m/h seemed to increase the initial velocity of the tracer wave and the distance it moved. However, returns were recorded only in the adjacent wells WK61 and WK63 with a very small, and three days delayed, response in WK43

  10. Positron emission tomography with additional γ-ray detectors for multiple-tracer imaging.

    Science.gov (United States)

    Fukuchi, Tomonori; Okauchi, Takashi; Shigeta, Mika; Yamamoto, Seiichi; Watanabe, Yasuyoshi; Enomoto, Shuichi

    2017-06-01

    Positron emission tomography (PET) is a useful imaging modality that quantifies the physiological distributions of radiolabeled tracers in vivo in humans and animals. However, this technique is unsuitable for multiple-tracer imaging because the annihilation photons used for PET imaging have a fixed energy regardless of the selection of the radionuclide tracer. This study developed a multi-isotope PET (MI-PET) system and evaluated its imaging performance. Our MI-PET system is composed of a PET system and additional γ-ray detectors. The PET system consists of pixelized gadolinium orthosilicate (GSO) scintillation detectors and has a ring geometry that is 95 mm in diameter with an axial field of view of 37.5 mm. The additional detectors are eight bismuth germanium oxide (BGO) scintillation detectors, each of which is 50 × 50 × 30 mm 3 , arranged into two rings mounted on each side of the PET ring with a 92-mm-inner diameter. This system can distinguish between different tracers using the additional γ-ray detectors to observe prompt γ-rays, which are emitted after positron emission and have an energy intrinsic to each radionuclide. Our system can simultaneously acquire double- (two annihilation photons) and triple- (two annihilation photons and a prompt γ-ray) coincidence events. The system's efficiency for detecting prompt de-excitation γ-rays was measured using a positron-γ emitter, 22 Na. Dual-radionuclide ( 18 F and 22 Na) imaging of a rod phantom and a mouse was performed to demonstrate the performance of the developed system. Our system's basic performance was evaluated by reconstructing two images, one containing both tracers and the other containing just the second tracer, from list-mode data sets that were categorized by the presence or absence of the prompt γ-ray. The maximum detection efficiency for 1275 keV γ-rays emitted from 22 Na was approximately 7% at the scanner's center, and the minimum detection efficiency was 5.1% at the edge of

  11. Statistically Based Morphodynamic Modeling of Tracer Slowdown

    Science.gov (United States)

    Borhani, S.; Ghasemi, A.; Hill, K. M.; Viparelli, E.

    2017-12-01

    Tracer particles are used to study bedload transport in gravel-bed rivers. One of the advantages associated with using of tracer particles is that they allow for direct measures of the entrainment rates and their size distributions. The main issue in large scale studies with tracer particles is the difference between tracer stone short term and long term behavior. This difference is due to the fact that particles undergo vertical mixing or move to less active locations such as bars or even floodplains. For these reasons the average virtual velocity of tracer particle decreases in time, i.e. the tracer slowdown. In summary, tracer slowdown can have a significant impact on the estimation of bedload transport rate or long term dispersal of contaminated sediment. The vast majority of the morphodynamic models that account for the non-uniformity of the bed material (tracer and not tracer, in this case) are based on a discrete description of the alluvial deposit. The deposit is divided in two different regions; the active layer and the substrate. The active layer is a thin layer in the topmost part of the deposit whose particles can interact with the bed material transport. The substrate is the part of the deposit below the active layer. Due to the discrete representation of the alluvial deposit, active layer models are not able to reproduce tracer slowdown. In this study we try to model the slowdown of tracer particles with the continuous Parker-Paola-Leclair morphodynamic framework. This continuous, i.e. not layer-based, framework is based on a stochastic description of the temporal variation of bed surface elevation, and of the elevation specific particle entrainment and deposition. Particle entrainment rates are computed as a function of the flow and sediment characteristics, while particle deposition is estimated with a step length formulation. Here we present one of the first implementation of the continuum framework at laboratory scale, its validation against

  12. Asian Tracer Experiment and Atmospheric Modeling (TEAM) Project: Draft Field Work Plan for the Asian Long-Range Tracer Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Allwine, K Jerry; Flaherty, Julia E.

    2007-08-01

    This report provides an experimental plan for a proposed Asian long-range tracer study as part of the international Tracer Experiment and Atmospheric Modeling (TEAM) Project. The TEAM partners are China, Japan, South Korea and the United States. Optimal times of year to conduct the study, meteorological measurements needed, proposed tracer release locations, proposed tracer sampling locations and the proposed durations of tracer releases and subsequent sampling are given. Also given are the activities necessary to prepare for the study and the schedule for completing the preparation activities leading to conducting the actual field operations. This report is intended to provide the TEAM members with the information necessary for planning and conducting the Asian long-range tracer study. The experimental plan is proposed, at this time, to describe the efforts necessary to conduct the Asian long-range tracer study, and the plan will undoubtedly be revised and refined as the planning goes forward over the next year.

  13. Catchment tracers reveal discharge, recharge and sources of groundwater-borne pollutants in a novel lake modelling approach

    Science.gov (United States)

    Kristensen, Emil; Madsen-Østerbye, Mikkel; Massicotte, Philippe; Pedersen, Ole; Markager, Stiig; Kragh, Theis

    2018-02-01

    Groundwater-borne contaminants such as nutrients, dissolved organic carbon (DOC), coloured dissolved organic matter (CDOM) and pesticides can have an impact the biological quality of lakes. The sources of pollutants can, however, be difficult to identify due to high heterogeneity in groundwater flow patterns. This study presents a novel approach for fast hydrological surveys of small groundwater-fed lakes using multiple groundwater-borne tracers. Water samples were collected from the lake and temporary groundwater wells, installed every 50 m within a distance of 5-45 m to the shore, were analysed for tracer concentrations of CDOM, DOC, total dissolved nitrogen (TDN, groundwater only), total nitrogen (TN, lake only), total dissolved phosphorus (TDP, groundwater only), total phosphorus (TP, lake only), δ18O / δ16O isotope ratios and fluorescent dissolved organic matter (FDOM) components derived from parallel factor analysis (PARAFAC). The isolation of groundwater recharge areas was based on δ18O measurements and areas with a high groundwater recharge rate were identified using a microbially influenced FDOM component. Groundwater discharge sites and the fractions of water delivered from the individual sites were isolated with the Community Assembly via Trait Selection model (CATS). The CATS model utilized tracer measurements of TDP, TDN, DOC and CDOM from the groundwater samples and related these to the tracer measurements of TN, TP, DOC and CDOM in the lake. A direct comparison between the lake and the inflowing groundwater was possible as degradation rates of the tracers in the lake were taken into account and related to a range of water retention times (WRTs) of the lake (0.25-3.5 years in 0.25-year increments). These estimations showed that WRTs above 2 years required a higher tracer concentration of inflowing water than found in any of the groundwater wells around the lake. From the estimations of inflowing tracer concentration, the CATS model isolated

  14. Tracer research in process engineering

    International Nuclear Information System (INIS)

    Iller, E.

    1992-01-01

    The book is a review of modern applications of tracer techniques in chemical and process engineering studies. The next topics have been extensively presented: 1) media flow through apparatus; 2) the tracers in the study of media flow dynamics through apparatus; 3) mathematical interpretation of experimental data from impulse-response method; 4) the models of media flow through chemical reactors and apparatus; 5) radiotracers in mass transport study; 6) examples of practical applications of tracer methods in industrial objects. 84 refs, 96 figs, 31 tabs

  15. New SPECT tracers: Example of tracers of proteoglycans and melanin

    International Nuclear Information System (INIS)

    Cachin, F.; Mestas, D.; Kelly, A.; Merlin, C.; Veyre, A.; Maublant, J.; Cachin, F.; Chezal, J.M.; Miot-Noirault, E.; Moins, N.; Auzeloux, P.; Vidal, A.; Bonnet-Duquennoy, M.; Boisgard, S.; D'Incan, M.; Madelmont, J.C.; Maublant, J.; Boisgard, S.; D'Incan, M.; Redini, F.; Filaire, M.

    2009-01-01

    The majority of research program on new radiopharmaceuticals turn to tracers used for positron emission tomography (PET). Only a few teams work on new non fluorine labeled tracers. However, the coming of SPECT/CT gamma cameras, the arrival of semi-conductors gamma cameras should boost the development of non-PET tracers. We exhibit in this article the experience acquired by our laboratory in the conception and design of two new non fluorine labelled compounds. The 99m Tc-N.T.P. 15-5 (N.T.P. 15-5 for N-[tri-ethyl-ammonium]-3-propyl-[15]ane-N5) which binds to proteoglycans could be used for the diagnosis and staging of osteoarthritis and chondrosarcoma. The iodo benzamides, specific to the melanin, are nowadays compared to 18 F-fluorodeoxyglucose in a phase III clinical trial for the diagnosis and detection of melanoma metastasis. Our last development focus on N-[2-(diethyl-amino)ethyl]-4 and 2-iodo benzamides respectively B.Z.A. and B.Z.A.2 hetero-aromatic analogues usable for melanoma treatment. (authors)

  16. Gas-phase naphthalene concentration data recovery in ambient air and its relevance as a tracer of sources of volatile organic compounds

    Science.gov (United States)

    Uria-Tellaetxe, Iratxe; Navazo, Marino; de Blas, Maite; Durana, Nieves; Alonso, Lucio; Iza, Jon

    2016-04-01

    Despite the toxicity of naphthalene and the fact that it is a precursor of atmospheric photooxidants and secondary aerosol, studies on ambient gas-phase naphthalene are generally scarce. Moreover, as far as we are concerned, this is the first published one using long-term hourly ambient gas-phase naphthalene concentrations. In this work, it has been also demonstrated the usefulness of ambient gas-phase naphthalene to identify major sources of volatile organic compounds (VOC) in complex scenarios. Initially, in order to identify main benzene emission sources, hourly ambient measurements of 60 VOC were taken during a complete year together with meteorological data in an urban/industrial area. Later, due to the observed co-linearity of some of the emissions, a procedure was developed to recover naphthalene concentration data from recorded chromatograms to use it as a tracer of the combustion and distillation of petroleum products. The characteristic retention time of this compound was determined comparing previous GC-MS and GC-FID simultaneous analysis by means of relative retention times, and its concentration was calculated by using relative response factors. The obtained naphthalene concentrations correlated fairly well with ethene (r = 0.86) and benzene (r = 0.92). Besides, the analysis of daily time series showed that these compounds followed a similar pattern, very different from that of other VOC, with minimum concentrations at day-time. This, together with the results from the assessment of the meteorological dependence pointed out a coke oven as the major naphthalene and benzene emitting sources in the study area.

  17. Using the tracer-dilution discharge method to develop streamflow records for ice-affected streams in Colorado

    Science.gov (United States)

    Capesius, Joseph P.; Sullivan, Joseph R.; O'Neill, Gregory B.; Williams, Cory A.

    2005-01-01

    Accurate ice-affected streamflow records are difficult to obtain for several reasons, which makes the management of instream-flow water rights in the wintertime a challenging endeavor. This report documents a method to improve ice-affected streamflow records for two gaging stations in Colorado. In January and February 2002, the U.S. Geological Survey, in cooperation with the Colorado Water Conservation Board, conducted an experiment using a sodium chloride tracer to measure streamflow under ice cover by the tracer-dilution discharge method. The purpose of this study was to determine the feasibility of obtaining accurate ice-affected streamflow records by using a sodium chloride tracer that was injected into the stream. The tracer was injected at two gaging stations once per day for approximately 20 minutes for 25 days. Multiple-parameter water-quality sensors at the two gaging stations monitored background and peak chloride concentrations. These data were used to determine discharge at each site. A comparison of the current-meter streamflow record to the tracer-dilution streamflow record shows different levels of accuracy and precision of the tracer-dilution streamflow record at the two sites. At the lower elevation and warmer site, Brandon Ditch near Whitewater, the tracer-dilution method overestimated flow by an average of 14 percent, but this average is strongly biased by outliers. At the higher elevation and colder site, Keystone Gulch near Dillon, the tracer-dilution method experienced problems with the tracer solution partially freezing in the injection line. The partial freezing of the tracer contributed to the tracer-dilution method underestimating flow by 52 percent at Keystone Gulch. In addition, a tracer-pump-reliability test was conducted to test how accurately the tracer pumps can discharge the tracer solution in conditions similar to those used at the gaging stations. Although the pumps were reliable and consistent throughout the 25-day study period

  18. [18F]FE@SNAP—A new PET tracer for the melanin concentrating hormone receptor 1 (MCHR1): Microfluidic and vessel-based approaches

    Science.gov (United States)

    Philippe, Cécile; Ungersboeck, Johanna; Schirmer, Eva; Zdravkovic, Milica; Nics, Lukas; Zeilinger, Markus; Shanab, Karem; Lanzenberger, Rupert; Karanikas, Georgios; Spreitzer, Helmut; Viernstein, Helmut; Mitterhauser, Markus; Wadsak, Wolfgang

    2012-01-01

    Changes in the expression of the melanin concentrating hormone receptor 1 (MCHR1) are involved in a variety of pathologies, especially obesity and anxiety disorders. To monitor these pathologies in-vivo positron emission tomography (PET) is a suitable method. After the successful radiosynthesis of [11C]SNAP-7941—the first PET-Tracer for the MCHR1, we aimed to synthesize its [18F]fluoroethylated analogue: [18F]FE@SNAP. Therefore, microfluidic and vessel-based approaches were tested. [18F]fluoroethylation was conducted via various [18F]fluoroalkylated synthons and direct [18F]fluorination. Only the direct [18F]fluorination of a tosylated precursor using a flow-through microreactor was successful, affording [18F]FE@SNAP in 44.3 ± 2.6%. PMID:22921745

  19. Developing biogeochemical tracers of apatite weathering by ectomycorrhizal fungi

    Science.gov (United States)

    Vadeboncoeur, M. A.; Bryce, J. G.; Hobbie, E. A.; Meana-Prado, M. F.; Blichert-Toft, J.

    2012-12-01

    Chronic acid deposition has depleted calcium (Ca) from many New England forest soils, and intensive harvesting may reduce phosphorus (P) available to future rotations. Thin glacial till soils contain trace amounts of apatite, a primary calcium phosphate mineral, which may be an important long-term source of both P and Ca to ecosystems. The extent to which ECM fungi enhance the weathering rate of primary minerals in soil which contain growth-limiting nutrients remains poorly quantified, in part due to biogeochemical tracers which are subsequently masked by within-plant fractionation. Rare earth elements (REEs) and Pb isotope ratios show some potential for revealing differences in soil apatite weathering rates across forest stands and silvicultural treatments. To test the utility of these tracers, we grew birch seedlings semi-hydroponically under controlled P-limited conditions, supplemented with mesh bags containing granite chips. Our experimental design included nonmycorrhizal (NM) as well as ectomycorrhizal cultures (Cortinarius or Leccinum). Resulting mycorrhizal roots and leachates of granite chips were analyzed for these tracers. REE concentrations in roots were greatly elevated in treatments with granite relative to those without granite, demonstrating uptake of apatite weathering products. Roots with different mycorrhizal fungi accumulated similar concentrations of REEs and were generally elevated compared to the NM cultures. Ammonium chloride leaches of granite chips grown in contact with mycorrhizal hyphae show elevated REE concentrations and significantly radiogenic Pb isotope signatures relative to bulk rock, also supporting enhanced apatite dissolution. Our results in culture are consistent with data from field-collected sporocarps from hardwood stands in the Bartlett Experimental Forest in New Hampshire, in which Cortinarius sporocarp Pb isotope ratios were more radiogenic than those of other ectomycorrhizal sporocarps. Taken together, the experimental

  20. Compilation and analyses of results from cross-hole tracer tests with conservative tracers

    Energy Technology Data Exchange (ETDEWEB)

    Hjerne, Calle; Nordqvist, Rune; Harrstroem, Johan (Geosigma AB (Sweden))

    2010-09-15

    Radionuclide transport in hydrogeological formations is one of the key factors for the safety analysis of a future repository of nuclear waste. Tracer tests have therefore been an important field method within the SKB investigation programmes at several sites since the late 1970's. This report presents a compilation and analyses of results from cross-hole tracer tests with conservative tracers performed within various SKB investigations. The objectives of the study are to facilitate, improve and reduce uncertainties in predictive tracer modelling and to provide supporting information for SKB's safety assessment of a final repository of nuclear waste. More specifically, the focus of the report is the relationship between the tracer mean residence time and fracture hydraulic parameters, i.e. the relationship between mass balance aperture and fracture transmissivity, hydraulic diffusivity and apparent storativity. For 74 different combinations of pumping and injection section at six different test sites (Studsvik, Stripa, Finnsjoen, Aespoe, Forsmark, Laxemar), estimates of mass balance aperture from cross-hole tracer tests as well as transmissivity were extracted from reports or in the SKB database Sicada. For 28 of these combinations of pumping and injection section, estimates of hydraulic diffusivity and apparent storativity from hydraulic interference tests were also found. An empirical relationship between mass balance aperture and transmissivity was estimated, although some uncertainties for individual data exist. The empirical relationship between mass balance aperture and transmissivity presented in this study deviates considerably from other previously suggested relationships, such as the cubic law and transport aperture as suggested by /Dershowitz and Klise 2002/, /Dershowitz et al. 2002/ and /Dershowitz et al. 2003/, which also is discussed in this report. No clear and direct empirical relationship between mass balance aperture and hydraulic

  1. Radioactive tracers in the sea

    International Nuclear Information System (INIS)

    Jenkins, W.J.; Livingston, H.D.

    1980-01-01

    Artificial radionuclides introduced to the oceans during the last four decades have proved invaluable tools for study of many processes in marine water columns and sediments. Both global and close-in fallout of radioactivity from atmospheric nuclear weapons testing have distributed these radionuclides widely, and in amounts sufficient to be useful as tracers. An additional source of considerable significance and tracer potential comes from coastal discharges of European nuclear fuel reprocessing wastes. The nature of these sources, types and amounts of radionuclides introduced and the time histories of their introduction generate a variety of tracer distributions which illuminate a broad spectrum of physical and chemical processes active over a wide range of timescales. Depending on their respective chemistries, artificial radionuclides have been demonstrated to exhibit both conservative and non-conservative properties in the oceans. Some examples are given of the uses made of soluble, conservative tracers for the study of oceanic transport processes and of non-conservative tracers for studies of processes which move them to, and mix them within, marine sediments. Sampling and measurement techniques which have been used in these studies are described

  2. Tracer filamentation at an unstable ocean front

    Science.gov (United States)

    Feng, Yen Chia; Mahadevan, Amala; Thiffeault, Jean-Luc; Yecko, Philip

    2017-11-01

    A front, where two bodies of ocean water with different physical properties meet, can become unstable and lead to a flow with high strain rate and vorticity. Phytoplankton and other oceanic tracers are stirred into filaments by such flow fields, as can often be seen in satellite imagery. The stretching and folding of a tracer by a two-dimensional flow field has been well studied. In the ocean, however, the vertical shear of horizontal velocity is typically two orders of magnitude larger than the horizontal velocity gradient. Theoretical calculations show that vertical shear alters the way in which horizontal strain affects the tracer, resulting in thin, sloping structures in the tracer field. Using a non-hydrostatic ocean model of an unstable ocean front, we simulate tracer filamentation to identify the effect of vertical shear on the deformation of the tracer. In a complementary laboratory experiment, we generate a simple, vertically sheared strain flow and use dye and particle image velocimetry to quantify the filamentary structures in terms of the strain and shear. We identify how vertical shear alters the tracer filaments and infer how the evolution of tracers in the ocean will differ from the idealized two-dimensional paradigm. Support of NSF DMS-1418956 is acknowledged.

  3. Tracer dispersion - experiment and CFD

    International Nuclear Information System (INIS)

    Zitny, R.

    2004-01-01

    Description of tracer distribution by means of dispersion models is a method successfully used in process engineering for fifty years. Application of dispersion models in reactor engineering for characterization of flows in column apparatus, heat exchangers, etc. is summarized and experimental tracer techniques as well as CFD methods for dispersion coefficients evaluation are discussed. Possible extensions of thermal axial dispersion model (ADM) and a core-wall ADM model suitable for description of tracer dispersion in laminar flows are suggested as well as CFD implementation as 1D finite elements. (author)

  4. Selection of tracers for oil and gas evaluation

    International Nuclear Information System (INIS)

    Bjoernstad, T.

    1991-08-01

    The importance of tracer tests in reservoir descriptions is increasingly acknowledged by reservoir engineers as a method to obtain valuable dynamic information from the reservoir. The report describes the ''state-of-the art'' on tracer technology for interwell investigations. Experiences gained from a number of reported field tracer tests are reviewed, and results from detailed laboratory investigations on the static and dynamic behavior of various tracer molecules are discussed. A critical evaluation of the applicability of the various identified tracers is provided. Present and future trends in the development of tracer technology for reservoir description are sketched. 64 refs., 12 figs., 2 tabs

  5. Towards tracer dose reduction in PET studies: Simulation of dose reduction by retrospective randomized undersampling of list-mode data.

    Science.gov (United States)

    Gatidis, Sergios; Würslin, Christian; Seith, Ferdinand; Schäfer, Jürgen F; la Fougère, Christian; Nikolaou, Konstantin; Schwenzer, Nina F; Schmidt, Holger

    2016-01-01

    Optimization of tracer dose regimes in positron emission tomography (PET) imaging is a trade-off between diagnostic image quality and radiation exposure. The challenge lies in defining minimal tracer doses that still result in sufficient diagnostic image quality. In order to find such minimal doses, it would be useful to simulate tracer dose reduction as this would enable to study the effects of tracer dose reduction on image quality in single patients without repeated injections of different amounts of tracer. The aim of our study was to introduce and validate a method for simulation of low-dose PET images enabling direct comparison of different tracer doses in single patients and under constant influencing factors. (18)F-fluoride PET data were acquired on a combined PET/magnetic resonance imaging (MRI) scanner. PET data were stored together with the temporal information of the occurrence of single events (list-mode format). A predefined proportion of PET events were then randomly deleted resulting in undersampled PET data. These data sets were subsequently reconstructed resulting in simulated low-dose PET images (retrospective undersampling of list-mode data). This approach was validated in phantom experiments by visual inspection and by comparison of PET quality metrics contrast recovery coefficient (CRC), background-variability (BV) and signal-to-noise ratio (SNR) of measured and simulated PET images for different activity concentrations. In addition, reduced-dose PET images of a clinical (18)F-FDG PET dataset were simulated using the proposed approach. (18)F-PET image quality degraded with decreasing activity concentrations with comparable visual image characteristics in measured and in corresponding simulated PET images. This result was confirmed by quantification of image quality metrics. CRC, SNR and BV showed concordant behavior with decreasing activity concentrations for measured and for corresponding simulated PET images. Simulation of dose

  6. Characterization of positron emission tomography hypoxia tracer uptake and tissue oxygenation via electrochemical modeling

    Energy Technology Data Exchange (ETDEWEB)

    Bowen, Stephen R., E-mail: srbowen@wisc.edu [University of Wisconsin School of Medicine and Public Health, Department of Medical Physics, Madison, WI 53706 (United States); Kogel, Albert J. van der [University Medical Centre St. Radboud, Nijmegen (Netherlands); Nordsmark, Marianne [Aarhus University Hospital, Department of Experimental Clinical Oncology, Aarhus (Denmark); Bentzen, Soren M. [University of Wisconsin School of Medicine and Public Health, Department of Medical Physics, Madison, WI 53706 (United States); University of Wisconsin School of Medicine and Public Health, Department of Human Oncology, Clinical Sciences Center, Madison, WI 53792 (United States); Jeraj, Robert [University of Wisconsin School of Medicine and Public Health, Department of Medical Physics, Madison, WI 53706 (United States); University of Wisconsin School of Medicine and Public Health, Department of Human Oncology, Clinical Sciences Center, Madison, WI 53792 (United States); Jozef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia)

    2011-08-15

    Purpose: Unique uptake and retention mechanisms of positron emission tomography (PET) hypoxia tracers make in vivo comparison between them challenging. Differences in imaged uptake of two common hypoxia radiotracers, [{sup 61}Cu]Cu-ATSM and [{sup 18}F]FMISO, were characterized via computational modeling to address these challenges. Materials and Methods: An electrochemical formalism describing bioreductive retention mechanisms of these tracers under steady-state conditions was adopted to relate time-averaged activity concentration to tissue partial oxygen tension (PO{sub 2}), a common metric of hypoxia. Chemical equilibrium constants of product concentration to reactant concentration ratios were determined from free energy changes and reduction potentials of pertinent reactions reported in the literature. Resulting transformation functions between tracer uptake and PO{sub 2} were compared against measured values in preclinical models. Additionally, calculated PO{sub 2} distributions from imaged Cu-ATSM tracer activity concentrations of 12 head and neck squamous cell carcinoma (HNSCC) patients were validated against microelectrode PO{sub 2} measurements in 69 HNSCC patients. Results: Both Cu-ASTM- and FMISO-modeled PO{sub 2} transformation functions were in agreement with preclinical measured values within single-deviation confidence intervals. High correlation (r{sup 2}=0.94, P<.05) was achieved between modeled PO{sub 2} distributions and measured distributions in the patient populations. On average, microelectrode hypoxia thresholds (2.5 and 5.0 mmHg) corresponded to higher Cu-ATSM uptake [2.5 and 2.0 standardized uptake value (SUV)] and lower FMISO uptake (2.0 and 1.4 SUV). Uncertainties in the models were dominated by variations in the estimated specific activity and intracellular acidity. Conclusions: Results indicated that the high dynamic range of Cu-ATSM uptake was representative of a narrow range of low oxygen tension whose values were dependent on

  7. Organic molecular tracers in the atmospheric aerosols from Lumbini, Nepal, in the northern Indo-Gangetic Plain: influence of biomass burning

    Directory of Open Access Journals (Sweden)

    X. Wan

    2017-07-01

    Full Text Available To better understand the characteristics of biomass burning in the northern Indo-Gangetic Plain (IGP, total suspended particles were collected in a rural site, Lumbini, Nepal, during April 2013 to March 2014 and analyzed for the biomass burning tracers (i.e., levoglucosan, mannosan, vanillic acid. The annual average concentration of levoglucosan was 734 ± 1043 ng m−3 with the maximum seasonal mean concentration during post-monsoon season (2206 ± 1753 ng m−3, followed by winter (1161 ± 1347 ng m−3, pre-monsoon (771 ± 524 ng m−3 and minimum concentration during monsoon season (212 ± 279 ng m−3. The other biomass burning tracers (mannosan, galactosan, p-hydroxybenzoic acid, vanillic acid, syringic acid and dehydroabietic acid also showed the similar seasonal variations. There were good correlations among levoglucosan, organic carbon (OC and elemental carbon (EC, indicating significant impact of biomass burning activities on carbonaceous aerosol loading throughout the year in Lumbini area. According to the characteristic ratios, levoglucosan ∕ mannosan (lev ∕ man and syringic acid ∕ vanillic acid (syr ∕ van, we deduced that the high abundances of biomass burning products during non-monsoon seasons were mainly caused by the burning of crop residues and hardwood while the softwood had less contribution. Based on the diagnostic tracer ratio (i.e., lev ∕ OC, the OC derived from biomass burning constituted large fraction of total OC, especially during post-monsoon season. By analyzing the MODIS fire spot product and 5-day air-mass back trajectories, we further demonstrated that organic aerosol composition was not only related to the local agricultural activities and residential biomass usage but also impacted by the regional emissions. During the post-monsoon season, the emissions from rice residue burning in western India and eastern Pakistan could impact particulate

  8. Tracer transport in fractured rocks

    International Nuclear Information System (INIS)

    Tsang, C.F.; Tsang, Y.W.; Hale, F.V.

    1988-07-01

    Recent interest in the safety of toxic waste underground disposal and nuclear waste geologic repositories has motivated many studies of tracer transport in fractured media. Fractures occur in most geologic formations and introduce a high degree of heterogeneity. Within each fracture, the aperture is not constant in value but strongly varying. Thus for such media, tracer tends to flow through preferred flowpaths or channels within the fractures. Along each of these channels, the aperture is also strongly varying. A detailed analysis is carried out on a 2D single fracture with variable apertures and the flow through channels is demonstrated. The channels defined this way are not rigidly set pathways for tracer transport, but are the preferred flow paths in the sense of stream-tubes in the potential theory. It is shown that such variable-aperture channels can be characterized by an aperture probability distribution function, and not by the exact deterministic geometric locations. We also demonstrate that the 2D tracer transport in a fracture can be calculated by a model of a system of 1D channels characterized by this distribution function only. Due to the channeling character of tracer transport in fractured rock, random point measurements of tracer breakthrough curves may give results with a wide spread in value due to statistical fluctuations. The present paper suggests that such a wide spread can probably be greatly reduced by making line/areal (or multiple) measurements covering a few spatial correlation lengths. 13 refs., 11 figs., 1 tab

  9. A study plan for determining recharge rates at the Hanford Site using environmental tracers

    International Nuclear Information System (INIS)

    Murphy, E.M.; Szercsody, J.E.; Phillips, S.J.

    1991-02-01

    This report presents a study plan for estimating recharge at the Hanford Site using environmental tracers. Past operations at the Hanford Site have led to both soil and groundwater contamination, and recharge is one of the primary mechanisms for transporting contaminants through the vadose zone and into the groundwater. An alternative to using fixed lysimeters for determining recharge rates in the vadose zone is to use environmental tracers. Tracers that have been used to study water movement in the vadose zone include total chloride, 36 Cl, 3 H, and 2 H/ 18 O. Atmospheric levels of 36 Cl and 3 H increased during nuclear bomb testing in the Pacific, and the resulting ''bomb pulse'' or peak concentration can be measured in the soil profile. Locally, past operations at the Hanford Site have resulted in the atmospheric release of numerous chemical and isotopic tracers, including nitrate, 129 I, and 99 Tc. Seven study sites on the Hanford Site have been selected, in two primary soil types that are believed to represent the extremes in recharge, the Quincy sand and the Warden silt loam. An additional background study site upwind of the Hanford facilities has been chosen at the Yakima Firing Center. Six tracer techniques (total chloride, 36 Cl, 3 H, nitrate, 129 I, and 99 Tc) will be tested on at least one site in the Quincy sand, one site in the Warden silt loam, and the background site, to determine which combination of tracers works best for a given soil type. In subsequent years, additional sites will be investigated. The use of environmental tracers is perhaps the only cost-effective method for estimating the spatial variability of recharge at a site as large as Hanford. The tracer techniques used at Hanford have wide applicability at other arid sites. 166 refs., 41 figs., 16 tabs

  10. Inverse modelling of atmospheric tracers: non-Gaussian methods and second-order sensitivity analysis

    Directory of Open Access Journals (Sweden)

    M. Bocquet

    2008-02-01

    Full Text Available For a start, recent techniques devoted to the reconstruction of sources of an atmospheric tracer at continental scale are introduced. A first method is based on the principle of maximum entropy on the mean and is briefly reviewed here. A second approach, which has not been applied in this field yet, is based on an exact Bayesian approach, through a maximum a posteriori estimator. The methods share common grounds, and both perform equally well in practice. When specific prior hypotheses on the sources are taken into account such as positivity, or boundedness, both methods lead to purposefully devised cost-functions. These cost-functions are not necessarily quadratic because the underlying assumptions are not Gaussian. As a consequence, several mathematical tools developed in data assimilation on the basis of quadratic cost-functions in order to establish a posteriori analysis, need to be extended to this non-Gaussian framework. Concomitantly, the second-order sensitivity analysis needs to be adapted, as well as the computations of the averaging kernels of the source and the errors obtained in the reconstruction. All of these developments are applied to a real case of tracer dispersion: the European Tracer Experiment [ETEX]. Comparisons are made between a least squares cost function (similar to the so-called 4D-Var approach and a cost-function which is not based on Gaussian hypotheses. Besides, the information content of the observations which is used in the reconstruction is computed and studied on the application case. A connection with the degrees of freedom for signal is also established. As a by-product of these methodological developments, conclusions are drawn on the information content of the ETEX dataset as seen from the inverse modelling point of view.

  11. Parameter Optimization for Quantitative Signal-Concentration Mapping Using Spoiled Gradient Echo MRI

    Directory of Open Access Journals (Sweden)

    Gasser Hathout

    2012-01-01

    Full Text Available Rationale and Objectives. Accurate signal to tracer concentration maps are critical to quantitative MRI. The purpose of this study was to evaluate and optimize spoiled gradient echo (SPGR MR sequences for the use of gadolinium (Gd-DTPA as a kinetic tracer. Methods. Water-gadolinium phantoms were constructed for a physiologic range of gadolinium concentrations. Observed and calculated SPGR signal to concentration curves were generated. Using a percentage error determination, optimal pulse parameters for signal to concentration mapping were obtained. Results. The accuracy of the SPGR equation is a function of the chosen MR pulse parameters, particularly the time to repetition (TR and the flip angle (FA. At all experimental values of TR, increasing FA decreases the ratio between observed and calculated signals. Conversely, for a constant FA, increasing TR increases this ratio. Using optimized pulse parameter sets, it is possible to achieve excellent accuracy (approximately 5% over a physiologic range of concentration tracer concentrations. Conclusion. Optimal pulse parameter sets exist and their use is essential for deriving accurate signal to concentration curves in quantitative MRI.

  12. Measurements of industrial fugitive emissions by the FTIR Tracer Method (FTM)

    International Nuclear Information System (INIS)

    Mellqvist, J.; Arlander, B.; Galle, B.; Bergqvist, B.

    1996-01-01

    A new method called the FTIR Tracer Method (FTM), has been developed for measuring and quantifying fugitive (diffuse) emissions of hydrocarbons. The method has been evaluated in field experiments which were conducted in the vicinity of several petrochemical plants and an oil refinery during 1993-1995. The technique is based on concentration measurements with infrared remote sensing by Long Path Fourier Transform InfraRed (LPFTIR), combined with tracer releases. The field experiments show the FTM to be very useful for mass flux measurements of both alkanes and alkenes and that the measurements are consistent with the conventional SF 6 method. However, the technique needs to be further validated and a more thorough understanding of the measurement uncertainties have to be achieved

  13. Determination of the solubility of low volatility liquid organic compounds in water using volatile-tracer assisted headspace gas chromatography.

    Science.gov (United States)

    Zhang, Shu-Xin; Chai, Xin-Sheng; Barnes, Donald G

    2016-02-26

    This study reports a new headspace gas chromatographic method (HS-GC) for the determination of water solubility of low volatility liquid organic compounds (LVLOs). The HS-GC analysis was performed on a set of aqueous solutions containing a range of concentrations of toluene-spiked (as a tracer) LVLOs, from under-saturation to over-saturation. A plot of the toluene tracer GC signal vs. the concentration of the LVLO results in two lines of different slopes that intersect at the concentration corresponding to the compound's solubility in water. The results showed that the HS-GC method has good precision (RSD waters of environmental and biological systems. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Radon as a groundwater tracer in Forsmark and Laxemar

    International Nuclear Information System (INIS)

    Grolander, Sara

    2009-10-01

    Radon concentrations were measured in different water types in Forsmark and Laxemar during the site investigation and within this study. From these measurements it can be concluded that large differences between surface water, near surface groundwater and deep groundwater can be found in both Laxemar and Forsmark. The differences in radon concentrations between different water types are used in this study to detect interactions between surface water, near surface water and deep groundwater. From the radon measurements it can also be concluded that radon concentration in deep groundwater varies largely with depth. These variations with depth are probably caused by groundwater flow in conductive fracture zones in the bedrock. The focus of this study has been the radon concentration of near surface groundwater and the interaction between near surface groundwater and deep groundwater. Radon measurements have been done using the RAD-7 radon detector within this study. It could be concluded that RAD-7 is a good technique for radon measurements and also easy to use in field. The radon concentrations measured in near surface groundwater in Laxemar within this study were low and homogenous. The variation in radon concentration has been analyses and compared to other parameters. Since the hypothesis of this study has been that there are differences in radon concentrations between recharging and discharging groundwater, the most important parameter to consider is the recharge/discharge field classification of the wells. No correlation between the recharge/discharge classifications of wells and the radon concentrations were found. The lack of correlation between groundwater flow patterns and radon concentration means that it is not possible to detect flow patterns in near surface groundwater using radon as a tracer in the Laxemar area. The lack of correlation can be caused by the fact that there are just a few wells located in areas classified as recharge area. It can also be

  15. Copper ion as a new leakage tracer.

    Science.gov (United States)

    Modaresi, J; Baharizade, M; Shareghi, A; Ahmadi, M; Daneshkazemi, A

    2013-12-01

    Most failures of root canal treatments are caused by bacteria. Studies showed that the most common cause of endodontic failures were the incomplete obturation of the root canal and the lack of adequate apical seal. Some in-vitro methods are used to estimate sealing quality, generally by measuring microleakage that allows the tracer agent to penetrate the filled canal. Conventional methods of evaluating the seal of endodontically treated teeth are complicated and have some drawbacks. We used copper ion diffusion method to assess the leakage and the results were compared to dye penetration method. The crowns of 21 extracted teeth were cut off at the CEJ level. After preparing the canals, the teeth were placed in tubes containing saline. They were divided randomly into 15 experimental cases; 3 positive and 3 negative controls. Positive controls were filled by single cone without sealer while the experimental and the negative control groups were filled by lateral technique. The coronal portion of gutta was removed and 9mm was left. The external surface of each tooth was coated with nail polish. Two millimeters of apical portion was immersed into 9ml of distilled water and 0.3ml of CuSO4 solution was injected into the coronal portion. After 2 days, copper sulfate was measured by an atomic absorption spectrophotometer. The teeth were then immersed in 2% methylene blue for 24 hours, sectioned and the extent of dye penetration was measured by a stereomicroscope. The maximum and minimum recorded copper ion concentrations for the experimental group were 18.37 and 2.87ppm respectively. The maximum and minimum recorded dye penetrations for the experimental group were 8.5 and 3.5mm respectively. The statistical analysis, adopting paired samples test, showed poor correlation between average recorded results of two methods. Based on our results, there was no significant correlation between the dye penetration and the copper ion diffusion methods.

  16. Tracer a application in marine outfall studies

    International Nuclear Information System (INIS)

    Genders, S.

    1979-01-01

    The applicability of radioactive and fluorescent tracers for field studies to predict or investigate waste water transport and dispersion from marine outfalls is evaluated. The application of either instantaneous or continuous tracer release, 'in situ' detection of tracers and data processing are considered. The necessity of a combined use of tracer techniques and conventional hydrographic methods for a statistical prediction of transport and dillution of waste water are pointed out. A procedure to determine an outlet distance from the coast, which satisfy bathing water criteria is outlined. (M.A.) [pt

  17. Bromide as a tracer for studying water movement and nitrate displacement in soils: comparison with stable isotope tracers; Bromid als Tracer zur Untersuchung der Wasserbewegung und der Nitratverlagerung in Boeden: Vergleich mit stabilisotopen Tracern

    Energy Technology Data Exchange (ETDEWEB)

    Russow, R.; Knappe, S. [UFZ - Umweltforschungszentrum Leipzig-Halle GmbH, Bad Lauchstaedt (Germany). Sektion Bodenforschung

    1999-02-01

    Tracers are an ideal means of studying water movement and associated nitrate displacement. Often bromide is preferred as a tracer because it is considered a representative tracer for water and because, being a conservative tracer (i.e. not involved in chemical and biological soil processes), it can be used for studying anion transport in soils. Moreover, it is less expensive and easier to measure than the stable isotopes deuterium and {sup 15}N. Its great advantage over radioactive tracers (e.g. tritium), which outweighs their extreme sensitivity and ease of measurement and which it has in common with stable isotopes, is that it does not require radiation protection measures. However, there are also constraints on the use of bromide as a tracer in soil/water/plant systems. Our own studies on different soils using D{sub 2}O, bromide and [{sup 15}N]-nitrate in lysimeters suggest that the above assumptions on bromide tracers need not always be valid under conditions as they prevail in biologically active soils. As the present paper shows, these studies permit a good assessment of the possibilities and limits to these tracers. [Deutsch] Fuer die Untersuchung der Wasserbewegung sowie der daran gekoppelten Nitrat-Verlagerung ist der Einsatz von Tracern das Mittel der Wahl. Dabei wird Bromid als Tracer haeufig bevorzugt, da es allgemein als ein repraesentativer Tracer fuer Wasser und als konservativer Tracer (nicht involviert in chemische und biologische Bodenprozesse) zur Untersuchung des Anionentransportes in Boeden angesehen wird und es gegenueber den stabilen Isotopen Deuterium und {sup 15}N billiger und einfacher zu bestimmen ist. Gegenueber den radioaktiven Tracern (z.B. Tritium), die zwar sehr empfindlich und einfach messbar sind, besteht der grosse Vorteil, dass, wie bei den stabilen Isotopen, keine Strahlenschutzmassnahmen ergriffen werden muessen. Es gibt jedoch auch einschraenkende Hinweise fuer die Verwendung von Bromid als Tracer im System Boden

  18. Hanford facilities tracer study report (315 Water Treatment Facility)

    International Nuclear Information System (INIS)

    Ambalam, T.

    1995-01-01

    This report presents the results and findings of a tracer study to determine contact time for the disinfection process of 315 Water Treatment Facility that supplies sanitary water for the 300 Area. The study utilized fluoride as the tracer and contact times were determined for two flow rates. Interpolation of data and short circuiting effects are also discussed. The 315 Water Treatment Facility supplies sanitary water for the 300 Area to various process and domestic users. The Surface Water Treatment Rule (SWTR), outlined in the 1986 Safe Drinking Water Act Amendments enacted by the EPA in 1989 and regulated by the Washington State Department of Health (DOH) in Section 246-290-600 of the Washington Administrative Code (WAC), stipulates filtration and disinfection requirements for public water systems under the direct influence of surface water. The SWTR disinfection guidelines require that each treatment system achieves predetermined inactivation ratios. The inactivation by disinfection is approximated with a measure called CxT, where C is the disinfectant residual concentration and T is the effective contact time of the water with the disinfectant. The CxT calculations for the Hanford water treatment plants were derived from the total volume of the contact basin(s). In the absence of empirical data to support CxT calculations, the DOH determined that the CxT values used in the monthly reports for the water treatment plants on the Hanford site were invalid and required the performance of a tracer study at each plant. In response to that determination, a tracer study will be performed to determine the actual contact times of the facilities for the CxT calculations

  19. Maximum neutron flux in thermal reactors

    International Nuclear Information System (INIS)

    Strugar, P.V.

    1968-12-01

    Direct approach to the problem is to calculate spatial distribution of fuel concentration if the reactor core directly using the condition of maximum neutron flux and comply with thermal limitations. This paper proved that the problem can be solved by applying the variational calculus, i.e. by using the maximum principle of Pontryagin. Mathematical model of reactor core is based on the two-group neutron diffusion theory with some simplifications which make it appropriate from maximum principle point of view. Here applied theory of maximum principle are suitable for application. The solution of optimum distribution of fuel concentration in the reactor core is obtained in explicit analytical form. The reactor critical dimensions are roots of a system of nonlinear equations and verification of optimum conditions can be done only for specific examples

  20. Tracers vs. trajectories in a coastal region

    Science.gov (United States)

    Engqvist, A.; Döös, K.

    2008-12-01

    Two different methods of estimating the water exchange through a Baltic coastal region have been used, consisting of particle trajectories and passive tracers. Water is traced from and to a small discharge region near the coast. The discharge material in this region is treated as zero dimensional particles or tracers with neutral buoyancy. The real discharge material could be a leakage of radio-nuclides through the sea floor from an underground repository of nuclear waste. Water exchange rates between the discharge region and the model domain are estimated using both forward and backward trajectories as well as passive tracers. The Lagrangian trajectories can account for the time evolution of the water exchange while the tracers give one average age per model grid box. Water exchange times such as residence time, age and transient times have been calculated with trajectories but only the average age (AvA) for tracers. The trajectory calculations provide a more detailed time evolution than the tracers. On the other hand the tracers are integrated "on-line" simultaneously in the sea circulation model with the same time step while the Lagrangian trajectories are integrated "off-line" from the stored model velocities with its inherent temporal resolution, presently one hour. The sub-grid turbulence is parameterised as a Laplacian diffusion for the passive tracers and with an extra stochastic velocity for trajectories. The importance of the parameterised sub-grid turbulence for the trajectories is estimated to give an extra diffusion of the same order as the Laplacian diffusion by comparing the Lagrangian dispersions with and without parameterisation. The results of the different methods are similar but depend on the chosen diffusivity coefficient with a slightly higher correlation between trajectories and tracers when integrated with a lower diffusivity coefficient.

  1. Plutonium as a tracer for soil erosion assessment in northeast China

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yihong [School of Geographic and Oceanographic Sciences, Nanjing University, Nanjing 210023 (China); Qiao, Jixin [Center for Nuclear Technologies, Technical University of Denmark, Risø Campus, DK-4000 Roskilde (Denmark); Pan, Shaoming, E-mail: span@nju.edu.cn [School of Geographic and Oceanographic Sciences, Nanjing University, Nanjing 210023 (China); Hou, Xiaolin, E-mail: xiho@dtu.dk [Center for Nuclear Technologies, Technical University of Denmark, Risø Campus, DK-4000 Roskilde (Denmark); Xi' an AMS Center, SKLLQG, Institute of Earth Environment, CAS, Xi' an 710075 (China); Roos, Per [Center for Nuclear Technologies, Technical University of Denmark, Risø Campus, DK-4000 Roskilde (Denmark); Cao, Liguo [School of Geographic and Oceanographic Sciences, Nanjing University, Nanjing 210023 (China)

    2015-04-01

    Soil erosion is one of the most serious environmental and agricultural problems faced by human society. Assessing intensity is an important issue for controlling soil erosion and improving eco-environmental quality. The suitability of the application of plutonium (Pu) as a tracer for soil erosion assessment in northeast China was investigated by comparing with that of {sup 137}Cs. Here we build on preliminary work, in which we investigated the potential of Pu as a soil erosion tracer by sampling additional reference sites and potential erosive sites, along the Liaodong Bay region in northeast China, for Pu isotopes and {sup 137}Cs. {sup 240}Pu/{sup 239}Pu atomic ratios in all samples were approximately 0.18, which indicated that the dominant source of Pu was the global fallout. Pu showed very similar distribution patterns to those of {sup 137}Cs at both uncultivated and cultivated sites. {sup 239+240}Pu concentrations in all uncultivated soil cores followed an exponential decline with soil depth, whereas at cultivated sites, Pu was homogenously distributed in plow horizons. Factors such as planted crop types, as well as methods and frequencies of irrigation and tillage were suggested to influence the distribution of radionuclides in cultivated land. The baseline inventories of {sup 239+240}Pu and {sup 137}Cs were 88.4 and 1688 Bq m{sup −2} respectively. Soil erosion rates estimated by {sup 239+240}Pu tracing method were consistent with those obtained by the {sup 137}Cs method, confirming that Pu is an effective tracer with a similar tracing behavior to that of {sup 137}Cs for soil erosion assessment. - Highlights: • The potential for the use of Pu as a soil erosion tracer was investigated. • Pu would be a good tracer given its long half-life. • Depth profiles of Pu in soils were systematically studied and compared to {sup 137}Cs. • Pu is an effective soil erosion tracer with behavior similar to that of {sup 137}Cs. • Thus, Pu provides a means of

  2. Dispersion of dissolved tracers released at the seafloor

    International Nuclear Information System (INIS)

    Kupferman, S.L.; Moore, D.E.

    1983-01-01

    The authors present scenarios that describe the temporal and spatial development of a concentration field of a dissolved tracer released at the seafloor for one Pacific and two Atlantic study areas. The scenarios are closely tied to available data by means of simple analytical models, and they proceed in stages from short time and space scales in the immediate vicinity of a release point to those scales characteristic of entire ocean basins. They introduce and discuss the concepts of internal mixing time and residence time in the benthic mixed layer, which are useful for developing an intuitive feeling for the behavior of a tracer. They also introduce the concept of domain of occupation, which is useful in drawing distinctions between mixing and stirring in the ocean. From this study it is apparent that reliable estimation of mixing will require careful consideration of the dynamics of the eddy fields in the ocean. In addition they urgently need more information that relates isopycnal structure and bottom topography to local near-bottom circulation

  3. Catchment tracers reveal discharge, recharge and sources of groundwater-borne pollutants in a novel lake modelling approach

    Directory of Open Access Journals (Sweden)

    E. Kristensen

    2018-02-01

    Full Text Available Groundwater-borne contaminants such as nutrients, dissolved organic carbon (DOC, coloured dissolved organic matter (CDOM and pesticides can have an impact the biological quality of lakes. The sources of pollutants can, however, be difficult to identify due to high heterogeneity in groundwater flow patterns. This study presents a novel approach for fast hydrological surveys of small groundwater-fed lakes using multiple groundwater-borne tracers. Water samples were collected from the lake and temporary groundwater wells, installed every 50 m within a distance of 5–45 m to the shore, were analysed for tracer concentrations of CDOM, DOC, total dissolved nitrogen (TDN, groundwater only, total nitrogen (TN, lake only, total dissolved phosphorus (TDP, groundwater only, total phosphorus (TP, lake only, δ18O ∕ δ16O isotope ratios and fluorescent dissolved organic matter (FDOM components derived from parallel factor analysis (PARAFAC. The isolation of groundwater recharge areas was based on δ18O measurements and areas with a high groundwater recharge rate were identified using a microbially influenced FDOM component. Groundwater discharge sites and the fractions of water delivered from the individual sites were isolated with the Community Assembly via Trait Selection model (CATS. The CATS model utilized tracer measurements of TDP, TDN, DOC and CDOM from the groundwater samples and related these to the tracer measurements of TN, TP, DOC and CDOM in the lake. A direct comparison between the lake and the inflowing groundwater was possible as degradation rates of the tracers in the lake were taken into account and related to a range of water retention times (WRTs of the lake (0.25–3.5 years in 0.25-year increments. These estimations showed that WRTs above 2 years required a higher tracer concentration of inflowing water than found in any of the groundwater wells around the lake. From the estimations of inflowing tracer concentration

  4. Assessing the Influence of Seasonal and Spatial Variations on the Estimation of Secondary Organic Carbon in Urban Particulate Matter by Applying the EC-Tracer Method

    Directory of Open Access Journals (Sweden)

    Sandra Wagener

    2014-04-01

    Full Text Available The elemental carbon (EC-tracer method was applied to PM10 and PM1 data of three sampling sites in the City of Berlin from February to October 2010. The sites were characterized by differing exposure to traffic and vegetation. The aim was to determine the secondary organic carbon (SOC concentration and to describe the parameters influencing the application of the EC-tracer method. The evaluation was based on comparisons with results obtained from positive matrix factorization (PMF applied to the same samples. To obtain site- and seasonal representative primary OC/EC-ratios ([OC/EC]p, the EC-tracer method was performed separately for each station, and additionally discrete for samples with high and low contribution of biomass burning. Estimated SOC-concentrations for all stations were between 11% and 33% of total OC. SOC-concentrations obtained with PMF exceeded EC-tracer results more than 100% at the park in the period with low biomass burning emissions in PM10. The deviations were besides others attributed to the high ratio of biogenic to combustion emissions and to direct exposure to vegetation. The occurrences of biomass burning emissions in contrast lead to increased SOC-concentrations compared to PMF in PM10. The obtained results distinguish that the EC-tracer-method provides well comparable results with PMF if sites are strongly influenced by one characteristic primary combustion source, but was found to be adversely influenced by direct and relatively high biogenic emissions.

  5. Principles and techniques of gamma ray tracers

    International Nuclear Information System (INIS)

    Claxton, K.T.

    1978-01-01

    Radioactive tracer techniques provide a very sensitive means of studying physical and chemical processes in a whole variety of different media. Some of the techniques and principles of radioactive tracers and their application to practical engineering systems are discussed. Information which has been found useful in the design of high temperature liquid sodium facilities employing radio-tracers, is presented. The report deals solely with the use of gamma-emitting species as the tracer. These find particular application for in-situ studies on engineering systems where the highly penetrating properties of gamma rays are needed for detection through strongly absorbent media such as stainless steel pepe walls. (author)

  6. Studies on influence of environmental factors on concentration on concentration of radionuclides

    International Nuclear Information System (INIS)

    Anon.

    1974-01-01

    Environmental factors which seemed to influence the concentration of radionuclides to marine organisms including illumination, water temperature, coexisting stable elements, salt concentration, suspended matters in sea water and residue were studied. The influence of illumination was examined by algae using 137 Cs, 60 Co, 85 Sr, and 106 Ru as tracers, within 24 hours of illumination. The concentration of 137 Cs and 60 Co revealed remarkable increase of uptake in accordance with increasing illumination intensity, and 24 hours illumination showed 2 times concentration of that by 4 hours'. 85 Sr and 106 Ru showed no effect of illumination, and suggested their concentration was depending on adsorption to the surface. As for water temperature, the concentration factor of 65 Zn, 137 Cs obtained from fishes and shells by 22 0 C breeding was 2 times of that by 12 0 C breeding. Concerning the influence of coexisting stable elements, fishes and shells were examined by 54 Mn, 60 Co, and 65 Zn as tracers. When the stable elements concentration in sea water became 10 times the normal, concentration factor depending on adsorption and metabolism became respective one tenth and one second of the normal value. The influence of salt concentration was examined using 85 Sr, 65 Zn, and 137 Cs, and revealed that 28 to 40 per cent changes of salt level gave slight influence on concentration factor. In order to study the influence of suspended matters and quality of residue, 3 kinds of 106 Ru complex species were added. Concentration factor of Hijiki (Hijikia fusiforme) showed no remarkable difference between breeding in filtrated and non-filtrated sea water. However, clams living in the sand should be taken care of the concentration by the residue in the sea bottom. (Kanao, N.)

  7. Development of Radon-222 as Natural Tracer for Monitoring the Remediation of NAPL in the Subsurface

    International Nuclear Information System (INIS)

    Davis, Brian M.; Semprini, Lewis; Istok, Jonathan

    2003-01-01

    Naturally occurring 222-radon in ground water can potentially be used as an in situ partitioning tracer to characterize dense nonaqueous phase liquid (DNAPL) saturations. The static method involves comparing radon concentrations in water samples from DNAPL-contaminated and non-contaminated portions of an aquifer. During a push-pull test, a known volume of test solution (radon-free water containing a conservation tracer) is first injected (''pushed'') into a well; flow is then reversed and the test solution/groundwater mixture is extracted (''pulled'') from the same well. In the presence of NAPL radon transport is retarded relative to the conservative tracer. Assuming linear equilibrium partitioning, retardation factors for radon can be used to estimate NAPL saturations.The utility of this methodology was evaluated in laboratory and field settings

  8. Focuss algorithm application in kinetic compartment modeling for PET tracer

    International Nuclear Information System (INIS)

    Huang Xinrui; Bao Shanglian

    2004-01-01

    Molecular imaging is in the process of becoming. Its application mostly depends on the molecular discovery process of imaging probes and drugs, from the mouse to the patient, from research to clinical practice. Positron emission tomography (PET) can non-invasively monitor . pharmacokinetic and functional processes of drugs in intact organisms at tracer concentrations by kinetic modeling. It has been known that for all biological systems, linear or nonlinear, if the system is injected by a tracer in a steady state, the distribution of the tracer follows the kinetics of a linear compartmental system, which has sums of exponential solutions. Based on the general compartmental description of the tracer's fate in vivo, we presented a novel kinetic modeling approach for the quantification of in vivo tracer studies with dynamic positron emission tomography (PET), which can determine a parsimonious model consisting with the measured data. This kinetic modeling technique allows for estimation of parametric images from a voxel based analysis and requires no a priori decision about the tracer's fate in vivo, instead determining the most appropriate model from the information contained within the kinetic data. Choosing a set of exponential functions, convolved with the plasma input function, as basis functions, the time activity curve of a region or a pixel can be written as a linear combination of the basis functions with corresponding coefficients. The number of non-zero coefficients returned corresponds to the model order which is related to the number of tissue compartments. The system macro parameters are simply determined using the focal underdetermined system solver (FOCUSS) algorithm. The FOCUSS algorithm is a nonparametric algorithm for finding localized energy solutions from limited data and is a recursive linear estimation procedure. FOCUSS algorithm usually converges very fast, so demands a few iterations. The effectiveness is verified by simulation and clinical

  9. Double tracer experiments to evaluate atmospheric transport and dose models

    International Nuclear Information System (INIS)

    Nielsen, S.P.; Gryning, S.-E.; Thykier-Nielsen, S.; Karlberg, O.; Lyck, E.

    1986-05-01

    Two tracers, sulphurhexafluoride (SF 6 ) and radioactive noble gases, were released simultaneously from a 110-m stack and detected downwind at distances of 3-4 km. The experiments were made at the Swedish nuclear power plant Ringhals in 1981. The radioactive tracer was routine emissions from unit 1 (BWR). The one-hour measurements yielded crosswind profiles at ground level of SF 6 -concentrations and of gamma radiation from the plume. The measured profiles were compared to profiles calculated with computer models. The comparison showed that the models sometimes underestimate and sometimes overestimate the results, which seems to indicate that the models within their limited accuracy yield unbiased results. The ratios between measured and calculated values range from 0.2 to 3. The measurements revealed a surplus of gamma radiations from the noble gas daughters compared to those from the gases. This was interpreted as due to ground desposition and the estimated deposition velocities range from 2 to 10 cm/s. The meteorological conditions were monitored from a 100-m meteorological tower and from an 11-m mast. Measurements were made of wind speed, wind direction, and temperatures at different heights, and during each experiment a mini-radiosonde was released giving information on a possible inversion layer. The SF 6 -tracer was injected to the stack prior to the experiments. Air-samples were collected downwind in plastic bags by radio-controlled sampling units. The SF 6 -concentrations in the bags were determined with gas chromatography. Measurements of the gamma radiation from the plume were made with ionisation chambers and GM-counters. Furthermore, a few mobile gamma spectrometers were available giving information on the unscattered gamma radiation, thereby permitting identification of the radioactive isotopes. The work was partly financed by the Nuclear Safety Board of the Swedish Utilities and by the Danish association of utilities in Jutland and on Funen, Elsam

  10. Representation of tropical deep convection in atmospheric models – Part 2: Tracer transport

    Directory of Open Access Journals (Sweden)

    C. R. Hoyle

    2011-08-01

    Full Text Available The tropical transport processes of 14 different models or model versions were compared, within the framework of the SCOUT-O3 (Stratospheric-Climate Links with Emphasis on the Upper Troposphere and Lower Stratosphere project. The tested models range from the regional to the global scale, and include numerical weather prediction (NWP, chemical transport, and chemistry-climate models. Idealised tracers were used in order to prevent the model's chemistry schemes from influencing the results substantially, so that the effects of modelled transport could be isolated. We find large differences in the vertical transport of very short-lived tracers (with a lifetime of 6 h within the tropical troposphere. Peak convective outflow altitudes range from around 300 hPa to almost 100 hPa among the different models, and the upper tropospheric tracer mixing ratios differ by up to an order of magnitude. The timing of convective events is found to be different between the models, even among those which source their forcing data from the same NWP model (ECMWF. The differences are less pronounced for longer lived tracers, however they could have implications for modelling the halogen burden of the lowermost stratosphere through transport of species such as bromoform, or short-lived hydrocarbons into the lowermost stratosphere. The modelled tracer profiles are strongly influenced by the convective transport parameterisations, and different boundary layer mixing parameterisations also have a large impact on the modelled tracer profiles. Preferential locations for rapid transport from the surface into the upper troposphere are similar in all models, and are mostly concentrated over the western Pacific, the Maritime Continent and the Indian Ocean. In contrast, models do not indicate that upward transport is highest over western Africa.

  11. The use of radioactive tracers in medicine. Part 2. The development of devices for imaging radionuclides

    International Nuclear Information System (INIS)

    Bailey, D.L.

    1996-01-01

    Tracer techniques have been used in medical research for more that two centuries. The history of the measurement of radiotracer in vivo is presented starting with non-imaging, quantitative measurements, and continuing with gamma cameras through to PET scanners. The latest represent the state-of-the-art due to the combination of in-vivo use of tracers with medical tomographic imaging. Its ability to correct accurately for attenuation makes it potentially quantifiable in radioactivity concentration terms and from this follows the ability to determine biological parameters non-invasively. 8 refs., 1 tab. 3 figs

  12. Improving Marine Ecosystem Models with Biochemical Tracers

    Science.gov (United States)

    Pethybridge, Heidi R.; Choy, C. Anela; Polovina, Jeffrey J.; Fulton, Elizabeth A.

    2018-01-01

    Empirical data on food web dynamics and predator-prey interactions underpin ecosystem models, which are increasingly used to support strategic management of marine resources. These data have traditionally derived from stomach content analysis, but new and complementary forms of ecological data are increasingly available from biochemical tracer techniques. Extensive opportunities exist to improve the empirical robustness of ecosystem models through the incorporation of biochemical tracer data and derived indices, an area that is rapidly expanding because of advances in analytical developments and sophisticated statistical techniques. Here, we explore the trophic information required by ecosystem model frameworks (species, individual, and size based) and match them to the most commonly used biochemical tracers (bulk tissue and compound-specific stable isotopes, fatty acids, and trace elements). Key quantitative parameters derived from biochemical tracers include estimates of diet composition, niche width, and trophic position. Biochemical tracers also provide powerful insight into the spatial and temporal variability of food web structure and the characterization of dominant basal and microbial food web groups. A major challenge in incorporating biochemical tracer data into ecosystem models is scale and data type mismatches, which can be overcome with greater knowledge exchange and numerical approaches that transform, integrate, and visualize data.

  13. Tracer monitoring of enhanced oil recovery projects

    Directory of Open Access Journals (Sweden)

    Kleven R.

    2013-05-01

    Full Text Available In enhanced oil recovery (EOR, chemicals are injected into the oil reservoir, either to increase macroscopic sweep efficiency, or to reduce remaining oil saturation in swept zones. Tracers can be used to identify reservoirs that are specifically suited for EOR operations. Injection of a selection of partitioning tracers, combined with frequent sample analysis of produced fluids, provides information suited for estimation of residual oil saturation. Tracers can also be used to evaluate and optimize the application of EOR chemicals in the reservoir. Suitable tracers will follow the EOR chemicals and assist in evaluation of retention, degradation or trapping. In addition to field applications, tracers also have a large potential as a tool to perform mechanistic studies of EOR chemicals in laboratory experiments. By labelling EOR chemicals with radioactive isotopes of elements such as H, C and S, detailed studies of transport mechanisms can be carried out. Co-injection of labelled compounds in dynamic flooding experiments in porous media will give information about retention or separation of the unique compounds constituting the chemical formulation. Separation of such compounds may be detrimental to obtaining the EOR effect expected. The paper gives new information of specific methods, and discusses current status for use of tracers in EOR operations.

  14. Prediction of the fate of radioactive material in the South Pacific Ocean using a global high-resolution ocean model

    International Nuclear Information System (INIS)

    Hazell, Douglas R.; England, Matthew H.

    2003-01-01

    We investigate the release of radioactive contaminants from Moruroa Atoll in a global high-resolution off-line model. The spread of tracer is studied in a series of simulations with varying release depths and time-scales, and into ocean velocity fields corresponding to long-term annual mean, seasonal, and interannually varying scenarios. In the instantaneous surface release scenarios we find that the incorporation of a seasonal cycle greatly influences tracer advection, with maximum concentrations still found within the French Polynesia region after 10 years. In contrast, the maximum trace is located in the southeast Pacific when long-term annual mean fields are used. This emphasizes the importance of the seasonal cycle in models of pollution dispersion on large scales. We further find that during an El Nino/Southern Oscillation (ENSO) event reduced currents in the region of Moruroa Atoll result in increased concentrations of radioactive material in French Polynesia, as direct flushing from the source is reduced. In terms of the sensitivity to tracer release time-rates, we find that a gradual input results in maximum concentrations in the near vicinity of French Polynesia. This contrasts the instantaneous-release scenarios, which see maximum concentrations and tracer spread across much of the South Pacific Ocean. For example, in as little as seven years radioactive contamination can reach the east coast of Australia diluted by only a factor of 1000 of the initial concentration. A comparison of results is made with previous studies. Overall, we find much higher concentrations of radionuclides in the South Pacific than has previously been predicted using coarser-resolution models

  15. Heat tracer methods

    Science.gov (United States)

    Healy, Richard W.; Scanlon, Bridget R.

    2010-01-01

    The flow of heat in the subsurface is closely linked to the movement of water (Ingebritsen et al., 2006). As such, heat has been used as a tracer in groundwater studies for more than 100 years (Anderson, 2005). As with chemical and isotopic tracers (Chapter 7), spatial or temporal trends in surface and subsurface temperatures can be used to infer rates of water movement. Temperature can be measured accurately, economically, at high frequencies, and without the need to obtain water samples, facts that make heat an attractive tracer. Temperature measurements made over space and time can be used to infer rates of recharge from a stream or other surface water body (Lapham, 1989; Stonestrom and Constantz, 2003); measurements can also be used to estimate rates of steady drainage through depth intervals within thick unsaturated zones (Constantz et al., 2003; Shan and Bodvarsson, 2004). Several thorough reviews of heat as a tracer in hydrologic studies have recently been published (Constantz et al., 2003; Stonestrom and Constantz, 2003; Anderson, 2005; Blasch et al., 2007; Constantz et al., 2008). This chapter summarizes heat-tracer approaches that have been used to estimate recharge.Some clarification in terminology is presented here to avoid confusion in descriptions of the various approaches that follow. Diffuse recharge is that which occurs more or less uniformly across large areas in response to precipitation, infiltration, and drainage through the unsaturated zone. Estimates of diffuse recharge determined using measured temperatures in the unsaturated zone are referred to as potential recharge because it is possible that not all of the water moving through the unsaturated zone will recharge the aquifer; some may be lost to the atmosphere by evaporation or plant transpiration. Estimated fluxes across confining units in the saturated zone are referred to as interaquifer flow (Chapter 1). Focused recharge is that which occurs directly from a point or line source, such

  16. Radiochemical tracers in marine biology

    International Nuclear Information System (INIS)

    Petrocelli, S.R.; Anderson, J.W.; Neff, J.M.

    1977-01-01

    Tracers have been used in a great variety of experimentation. More recently, labeled materials have been applied in marine biological research. Some of the existing tracer techniques have been utilized directly, while others have been modified to suit the specific needs of marine biologists. This chapter describes some of the uses of tracers in marine biological research. It also mentions the problems encountered as well as offering possible solutions and discusses further applications of these techniques. Only pertinent references are cited and additional information may be obtained by consulting these references. Due to their relative ease of maintenance, freshwater species are also utilized in studies which involve radiotracer techniques. Since most of these techniques e directly applicable to marine species, some of these studies will also be included

  17. Numerical simulation of passive tracer dispersion in the pacific ocean from Mururoa atoll (French Polynesia); Etude numerique de la dispersion d`un traceur dans le pacifique sud depuis l`atoll de Mururoa

    Energy Technology Data Exchange (ETDEWEB)

    Rancher, J.; Lazar, A.; Maes, Ch.

    1996-12-01

    In order to evaluate, on a Tropical South Pacific scale over 10 years, the consequences of an hypothetic radionuclide releases to the ocean from French Nuclear test sites, a series of numerical simulations was carried out. Tracer advection and diffusion terms were computed by a dispersion model without taking into account radioactive decay and biological interactions. Ocean dynamics and turbulent mixing coefficients were derived from a Ocean General circulation Model using annual average climatological fields. A punctual release with unit activity concentration throughout the depth showed the existence of two major directions of propagation from Mururoa atoll: one toward the Eastern Pacific when releases originated from 100-150 meters or less, and the other Westward if release depth is greater. The maximum concentrations which may possibly reach the continental South Pacific coastline originated from released points located in the 350 meters depth zone. Another experiment showed that an punctual release yields higher concentrations than the continuous release of an equivalent quantity over 10 years; two punctual releases were carried out at the characteristic depth of 5 m and 364 m: maximum concentrations decrease by factors of 10 000 and 1000 over ten years. A comparison is made with the surface release study of Ribbe and Tomczak (1990), despite a significant discrepancy in propagation direction, the order of magnitude for concentrations is comparable. (author).

  18. Defining optimal tracer activities in pediatric oncologic whole-body {sup 18}F-FDG-PET/MRI

    Energy Technology Data Exchange (ETDEWEB)

    Gatidis, Sergios; Schmidt, Holger; Nikolaou, Konstantin; Schwenzer, Nina F.; Schaefer, Juergen F. [University of Tuebingen, Department of Radiology, Diagnostic and Interventional Radiology, Tuebingen (Germany); La Fougere, Christian [University of Tuebingen, Department of Radiology, Nuclear Medicine, Tuebingen (Germany)

    2016-12-15

    To explore the feasibility of reducing administered tracer activities and to assess optimal activities for combined {sup 18}F-FDG-PET/MRI in pediatric oncology. 30 {sup 18}F-FDG-PET/MRI examinations were performed on 24 patients with known or suspected solid tumors (10 girls, 14 boys, age 12 ± 5.6 [1-18] years; PET scan duration: 4 min per bed position). Low-activity PET images were retrospectively simulated from the originally acquired data sets using randomized undersampling of list mode data. PET data of different simulated administered activities (0.25-2.5 MBq/kg body weight) were reconstructed with or without point spread function (PSF) modeling. Mean and maximum standardized uptake values (SUV{sub mean} and SUV{sub max}) as well as SUV variation (SUV{sub var}) were measured in physiologic organs and focal FDG-avid lesions. Detectability of organ structures and of focal {sup 18}F-FDG-avid lesions as well as the occurrence of false-positive PET lesions were assessed at different simulated tracer activities. Subjective image quality steadily declined with decreasing tracer activities. Compared to the originally acquired data sets, mean relative deviations of SUV{sub mean} and SUV{sub max} were below 5 % at {sup 18}F-FDG activities of 1.5 MBq/kg or higher. Over 95 % of anatomic structures and all pathologic focal lesions were detectable at 1.5 MBq/kg {sup 18}F-FDG. Detectability of anatomic structures and focal lesions was significantly improved using PSF. No false-positive focal lesions were observed at tracer activities of 1 MBq/kg {sup 18}F-FDG or higher. Administration of {sup 18}F-FDG activities of 1.5 MBq/kg is, thus, feasible without obvious diagnostic shortcomings, which is equivalent to a dose reduction of more than 50 % compared to current recommendations. Significant reduction in administered {sup 18}F-FDG tracer activities is feasible in pediatric oncologic PET/MRI. Appropriate activities of {sup 18}F-FDG or other tracers for specific clinical

  19. The use of bromine as a tracer for studying infiltrations in mining processes

    International Nuclear Information System (INIS)

    Diaz, F; Andonie, O; Rojas, X

    2003-01-01

    The impact of mining activity on underground water is becoming increasingly important because of the scarcity of the resource and due to the different use if there is water under the mining. Once the resource is affected the source of infiltration should be identified in all the processes and systems that are involved in the production system in order to take the appropriate preventive or remedial measures, which should also be the most efficient ones. Tracers play an important role in studying infiltration from mining processes to underground bodies of water. Natural chemical and isotopic tracers can identify the hydrogeological setting and help to establish supported hypotheses about the possible origin of the infiltrations. After the different ideas about the processes or systems that could be infiltrated are presented, the application of additional artificial tracers can resolve any doubts This work presents the use of bromine as a tracer for such studies, because of its specific characteristics as a good tracer in water with low interaction in porous surroundings, generally, and its determination by Neutron Activation Analyzers (NAA) due to its low limits of detection and the technique's precision and accuracy for use at reasonable costs. Given that for this type of study a large number of samples are necessary and that it should be carried out in a time period that does not surpass the duration of the process (a few months), a change had to be made in the methodology usually used for the NAA, which included taking a fraction of significantly less sample while meeting the power requirements for differentiating small changes in concentrations between samples. With this modification a larger number of samples can be irradiated in available positions for these purposes in the RECH-1 and the requirements for the number of samples and response time can be met. After the practical performance of this modification, a comparison between both methodologies was carried

  20. Utility of bromide and heat tracers for aquifer characterization affected by highly transient flow conditions

    Science.gov (United States)

    Ma, Rui; Zheng, Chunmiao; Zachara, John M.; Tonkin, Matthew

    2012-08-01

    A tracer test using both bromide and heat tracers conducted at the Integrated Field Research Challenge site in Hanford 300 Area (300A), Washington, provided an instrument for evaluating the utility of bromide and heat tracers for aquifer characterization. The bromide tracer data were critical to improving the calibration of the flow model complicated by the highly dynamic nature of the flow field. However, most bromide concentrations were obtained from fully screened observation wells, lacking depth-specific resolution for vertical characterization. On the other hand, depth-specific temperature data were relatively simple and inexpensive to acquire. However, temperature-driven fluid density effects influenced heat plume movement. Moreover, the temperature data contained "noise" caused by heating during fluid injection and sampling events. Using the hydraulic conductivity distribution obtained from the calibration of the bromide transport model, the temperature depth profiles and arrival times of temperature peaks simulated by the heat transport model were in reasonable agreement with observations. This suggested that heat can be used as a cost-effective proxy for solute tracers for calibration of the hydraulic conductivity distribution, especially in the vertical direction. However, a heat tracer test must be carefully designed and executed to minimize fluid density effects and sources of noise in temperature data. A sensitivity analysis also revealed that heat transport was most sensitive to hydraulic conductivity and porosity, less sensitive to thermal distribution factor, and least sensitive to thermal dispersion and heat conduction. This indicated that the hydraulic conductivity remains the primary calibration parameter for heat transport.

  1. Radon as a groundwater tracer in Forsmark and Laxemar

    Energy Technology Data Exchange (ETDEWEB)

    Grolander, Sara

    2009-10-15

    Radon concentrations were measured in different water types in Forsmark and Laxemar during the site investigation and within this study. From these measurements it can be concluded that large differences between surface water, near surface groundwater and deep groundwater can be found in both Laxemar and Forsmark. The differences in radon concentrations between different water types are used in this study to detect interactions between surface water, near surface water and deep groundwater. From the radon measurements it can also be concluded that radon concentration in deep groundwater varies largely with depth. These variations with depth are probably caused by groundwater flow in conductive fracture zones in the bedrock. The focus of this study has been the radon concentration of near surface groundwater and the interaction between near surface groundwater and deep groundwater. Radon measurements have been done using the RAD-7 radon detector within this study. It could be concluded that RAD-7 is a good technique for radon measurements and also easy to use in field. The radon concentrations measured in near surface groundwater in Laxemar within this study were low and homogenous. The variation in radon concentration has been analyses and compared to other parameters. Since the hypothesis of this study has been that there are differences in radon concentrations between recharging and discharging groundwater, the most important parameter to consider is the recharge/discharge field classification of the wells. No correlation between the recharge/discharge classifications of wells and the radon concentrations were found. The lack of correlation between groundwater flow patterns and radon concentration means that it is not possible to detect flow patterns in near surface groundwater using radon as a tracer in the Laxemar area. The lack of correlation can be caused by the fact that there are just a few wells located in areas classified as recharge area. It can also be

  2. Development and application of an iridium tracer for tracking tailings in the central Red Sea

    International Nuclear Information System (INIS)

    Schnier, C.; Fanger, H.U.

    1983-01-01

    In order to investigate the distribution of disposed tailings, the element iridium was applied as a tracer during the prepilot mining test in the Red Sea 1979. In the sediment matrix, Ir can be detected in quantities as small as 25 x 10 -12 g by means of neutron activation analysis. The tracer was obtained by melting down a mixture of 50 kg quartz and 1 kg IrO 2 , then grinding and pulverizing the material to an appropriate grain size distribution. An amount of 480 m 3 tracer-added tailings was disposed in a depth of 400 m close to the Atlantis II deep. Subsequently, in the period 1 month to 2 1/2 years later, 32 sediment samples were taken from the deposition area and analysed for Ir. The Ir concentration observed were surprisingly low and give only vague indications of the spreading of the tailings. (orig.) [de

  3. Fluoride tracer test for the performance analysis of a basin used as a lagooning pre-treatment facility in a WTP.

    Science.gov (United States)

    Ruffino, Barbara

    2015-07-01

    The water treatment plant (WTP) of the city of Torino (NW Italy), which treats about 40 · 10(6) m(3)/year of raw water from Po river, has a 15-ha basin used as a lagooning pre-treatment facility. Since the efficiency of the lagooning process in the removal of pollutants from raw water depends on the internal hydrodynamics of the basin, the hydraulic performance of the basin was studied by combining the results of a stimulus-response tracer test with the monitoring of the tracer (fluoride) concentration throughout the basin at different times. The outcomes of the test demonstrated that the system was efficiently mixed and could be assimilated to a continuous stirred reactor presenting no flow anomalies, with an actual mean residence time (RT) of 12.7 days, compared with a nominal RT of 18 days. This assured that dissolved contaminants (such as fluoride) coming from the river were efficiently diluted before entering the WTP. The axial dispersion coefficient calculated from the RT distribution was approximately 47,300 m(2)/day. Three of the most popular formulae developed for the calculation of the axial dispersion coefficient provided results spreading over three orders of magnitude, thus showing their limitations. Finally, because of the width extent of the basin and the characteristics of its inflow, the 1-D advection-dispersion model failed in predicting the tracer concentration values in time at the outlet channel. On the contrary, the analytical solution of the 2-D advection-dispersion model proved to be suitable to fit the tracer concentration data over time at the outlet channel but it failed in describing the tracer distribution throughout the basin on the monitoring dates.

  4. Using environmental tracers in modeling flow in a complex shallow aquifer system

    DEFF Research Database (Denmark)

    Troldborg, Lars; Jensen, Karsten Høgh; Engesgaard, Peter Knudegaard

    2008-01-01

    shapes and sizes without being similar to the assumed age distributions used in the analytical approach. The shape of age distribution to some extent depends on sampling size and on whether the system is modeled in a transient or in a steady state, but shape and size were largely driven......Using environmental tracers in groundwater dating partly relies on the assumption that groundwater age distribution can be described analytically. To investigate the applicability of age dating in complex multiaquifer systems, a methodology for simulating well specific groundwater age distribution...... was developed. Using a groundwater model and particle tracking we modeled age distributions at screen locations. By enveloping modeled age distributions and estimated recharge concentrations, environmental tracer breakthroughs were simulated for specific screens. Simulated age distributions are of irregular...

  5. Quantification of Nitrous Oxide from Fugitive Emissions by Tracer Dilution Method using a Mobile Real-time Nitrous Oxide Analyzer

    Science.gov (United States)

    Mønster, J.; Rella, C.; Jacobson, G. A.; He, Y.; Hoffnagle, J.; Scheutz, C.

    2012-12-01

    Nitrous oxide is a powerful greenhouse gas considered 298 times stronger than carbon dioxide on a hundred years term (Solomon et al. 2007). The increasing global concentration is of great concern and is receiving increasing attention in various scientific and industrial fields. Nitrous oxide is emitted from both natural and anthropogenic sources. Inventories of source specific fugitive nitrous oxide emissions are often estimated on the basis of modeling and mass balance. While these methods are well-developed, actual measurements for quantification of the emissions can be a useful tool for verifying the existing estimation methods as well as providing validation for initiatives targeted at lowering unwanted nitrous oxide emissions. One approach to performing such measurements is the tracer dilution method (Galle et al. 2001), in which a tracer gas is released at the source location at a known flow. The ratio of downwind concentrations of both the tracer gas and nitrous oxide gives the ratios of the emissions rates. This tracer dilution method can be done with both stationary and mobile measurements; in either case, real-time measurements of both tracer and analyte gas is required, which places high demands on the analytical detection method. To perform the nitrous oxide measurements, a novel, robust instrument capable of real-time nitrous oxide measurements has been developed, based on cavity ring-down spectroscopy and operating in the near-infrared spectral region. We present the results of the laboratory and field tests of this instrument in both California and Denmark. Furthermore, results are presented from measurements using the mobile plume method with a tracer gas (acetylene) to quantify the nitrous oxide and methane emissions from known sources such as waste water treatment plants and composting facilities. Nitrous oxide (blue) and methane (yellow) plumes downwind from a waste water treatment facility.

  6. Ground water pollution by roof runoff infiltration evidenced with multi-tracer experiments.

    Science.gov (United States)

    Ammann, Adrian A; Hoehn, Eduard; Koch, Sabine

    2003-03-01

    The infiltration of urban roof runoff into well permeable subsurface material may have adverse effects on the ground water quality and endanger drinking water resources. Precipitation water from three different roofs of an industrial complex was channelled to a pit and infiltrated into a perialpine glaciofluvial gravel-and-sand aquifer. A shaft was constructed at the bottom of the pit and equipped with an array of TDR probes, lysimeters and suction cups that allowed measuring and sampling soil water at different depths. A fast infiltration flow was observed during natural rainfall events and during artificial infiltration experiments. For a better understanding of the behaviour of contaminants, experiments were conducted with cocktails of compounds of different reactivity (ammonium, strontium, atratone) and of non-reactive tracers (uranine, bromide, naphthionate), which represent different classes of pollutants. The experiment identified cation exchange reactions influencing the composition of the infiltrating water. These processes occurred under preferential flow conditions in macropores of the material. Measuring concentration changes under the controlled inflow of tracer experiments, the pollution potential was found to be high. Non-reactive tracers exhibited fast breakthrough and little sorption.

  7. Method for assessment of stormwater treatment facilities - Synthetic road runoff addition including micro-pollutants and tracer.

    Science.gov (United States)

    Cederkvist, Karin; Jensen, Marina B; Holm, Peter E

    2017-08-01

    Stormwater treatment facilities (STFs) are becoming increasingly widespread but knowledge on their performance is limited. This is due to difficulties in obtaining representative samples during storm events and documenting removal of the broad range of contaminants found in stormwater runoff. This paper presents a method to evaluate STFs by addition of synthetic runoff with representative concentrations of contaminant species, including the use of tracer for correction of removal rates for losses not caused by the STF. A list of organic and inorganic contaminant species, including trace elements representative of runoff from roads is suggested, as well as relevant concentration ranges. The method was used for adding contaminants to three different STFs including a curbstone extension with filter soil, a dual porosity filter, and six different permeable pavements. Evaluation of the method showed that it is possible to add a well-defined mixture of contaminants despite different field conditions by having a flexibly system, mixing different stock-solutions on site, and use bromide tracer for correction of outlet concentrations. Bromide recovery ranged from only 12% in one of the permeable pavements to 97% in the dual porosity filter, stressing the importance of including a conservative tracer for correction of contaminant retention values. The method is considered useful in future treatment performance testing of STFs. The observed performance of the STFs is presented in coming papers. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Tracer disposition kinetics in the determination of local cerebral blood flow by a venous equilibrium model, tube model, and distributed model

    International Nuclear Information System (INIS)

    Sawada, Y.; Sugiyama, Y.; Iga, T.; Hanano, M.

    1987-01-01

    Tracer distribution kinetics in the determination of local cerebral blood flow (LCBF) were examined by using three models, i.e., venous equilibrium, tube, and distributed models. The technique most commonly used for measuring LCBF is the tissue uptake method, which was first developed and applied by Kety. The measurement of LCBF with the 14 C-iodoantipyrine (IAP) method is calculated by using an equation derived by Kety based on the Fick's principle and a two-compartment model of blood-tissue exchange and tissue concentration at a single data point. The procedure, in which the tissue is to be in equilibrium with venous blood, will be referred to as the tissue equilibration model. In this article, effects of the concentration gradient of tracer along the length of the capillary (tube model) and the transverse heterogeneity in the capillary transit time (distributed model) on the determination of LCBF were theoretically analyzed for the tissue sampling method. Similarities and differences among these models are explored. The rank order of the LCBF calculated by using arterial blood concentration time courses and the tissue concentration of tracer based on each model were tube model (model II) less than distributed model (model III) less than venous equilibrium model (model I). Data on 14 C-IAP kinetics reported by Ohno et al. were employed. The LCBFs calculated based on model I were 45-260% larger than those in models II or III. To discriminate among three models, we propose to examine the effect of altering the venous infusion time of tracer on the apparent tissue-to-blood concentration ratio (lambda app). A range of the ratio of the predicted lambda app in models II or III to that in model I was from 0.6 to 1.3

  9. A Study Plan for Determining Recharge Rates at the Hanford Site Using Environmental Tracers

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, E. M.; Szecsody, J. E.; Phillips, S. J.

    1991-02-01

    This report presents a study plan tor estimating recharge at the Hanford Site using environmental tracers. Past operations at the Hanford Site have led to both soil and groundwater contamination, and recharge is one of the primary mechanisms for transporting contaminants through the vadose zone and into the groundwater. The prediction of contaminant movement or transport is one aspect of performance assessment and an important step in the remedial investigation/feasibility study (RI/FS) process. In the past, recharge has been characterized by collecting lysimeter data. Although lysimeters can generate important and reliable data, their limitations include 1) fixed location, 2) fixed sediment contents, 3) edge effects, 4) low rates, and 5) relatively short duration of measurement. These limitations impact the ability to characterize the spatial distribution of recharge at the Hanford Site, and thus the ability to predict contaminant movement in the vadose zone. An alternative to using fixed lysimeters for determining recharge rates in the vadose zone is to use environmental tracers. Tracers that have been used to study water movement in the vadose zone include total chloride, {sup 36}CI, {sup 3}H, and {sup 2}H/{sup 18}O. Atmospheric levels of {sup 36}CI and {sup 3}H increased during nuclear bomb testing in the Pacific, and the resulting "bomb pulse" or peak concentration can be measured in the soil profile. Locally, past operations at the Hanford Site have resu~ed in the atmospheric release of numerous chemical and isotopic tracers, including nitrate, {sup 129}I, and {sup 99}Tc. The radionuclides, in particular, reached a well-defined atmospheric peak in 1945. Atmospheric releases of {sup 129}I and {sup 99}Tc were greatly reduced by mid-1946, but nitrogen oxides continued to be released from the uranium separations facilities. As a result, the nitrate concentrations probably peaked in the mid-1950s, when the greatest number of separations facilities were operating

  10. Atmospheric Tracer Depletion Testing for Unfiltered Air In-Leakage Determination at the Wolf Creek Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, T. M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Wilke, R. J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Roberts, T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Vignato, G. J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-03-01

    Atmospheric Tracer Depletion tests were conducted at the Wolf Creek Nuclear Power Plant to quantify the unfiltered in-leakage (UI) into the Control Room (CR), Control Building (CB), and Equipment Rooms (ER) at the Wolf Creek Nuclear Power Plant. Wolf Creek has two independent charcoal filter Emergency Ventilation Systems (EVS) that can be used to purify air entering the control building and control room. The Bravo System contains a filtration system in Room 1501 in the Auxiliary Building for the Control Room and another filtration system (FGK02B) on Elevation 2016 for the Control Building. The Alpha system contains a filtration system in Room 1512 in the Auxiliary Building for the Control Room and another filtration system (FGK02A) on Elevation 2016 for the Control Building. The Atmospheric Tracer Depletion (ATD) test is a technique to measure in-leakage using the concentration of perfluorocarbon compounds that have a constant atmospheric background. These levels are present in the Control Room and Control Building under normal operating conditions. When air is supplied by either of the EVS, most of the PFTS are removed by the charcoal filters. If the concentrations of the PFTs measured in protected areas are the same as the levels at the output of the EVS, the in-leakage of outside air into the protected area would be zero. If the concentration is higher in the protected area than at the output of the filter system, there is in-leakage and the in-leakage can be quantified by the difference. Sampling was performed using state-of-the-art Brookhaven Atmospheric Tracer Samplers (BATS) air sampling equipment and analysis performed on Brookhaven National Laboratory (BNL) dedicated PFT analytical systems. In the Alpha test two tracers PMCH and mcPDCH were used to determine in-leakage into the control building. The analytical system was tuned to maximize sensitivity after initial analysis of the Alpha test. The increased sensitivity permitted accurate quantification of

  11. Atmospheric Tracer Depletion Testing for Unfiltered Air In-Leakage Determination at the Wolf Creek Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, T. M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Wilke, R. J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Roberts, T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Vignato, G. J. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-04-01

    Atmospheric Tracer Depletion tests were conducted at the Wolf Creek Nuclear Power Plant to quantify the unfiltered in-leakage (UI) into the Control Room (CR), Control Building (CB), and Equipment Rooms (ER) at the Wolf Creek Nuclear Power Plant. Wolf Creek has two independent charcoal filter Emergency Ventilation Systems (EVS) that can be used to purify air entering the control building and control room. The Bravo System contains a filtration system in Room 1501 in the Auxiliary Building for the Control Room and another filtration system (FGK02B) on Elevation 2016 for the Control Building. The Alpha system contains a filtration system in Room 1512 in the Auxiliary Building for the Control Room and another filtration system (FGK02A) on Elevation 2016 for the Control Building.The Atmospheric Tracer Depletion (ATD) test is a technique to measure in-leakage using the concentration of perfluorocarbon compounds that have a constant atmospheric background. These levels are present in the Control Room and Control Building under normal operating conditions. When air is supplied by either of the EVS, most of the PFTS are removed by the charcoal filters. If the concentrations of the PFTs measured in protected areas are the same as the levels at the output of the EVS, the in-leakage of outside air into the protected area would be zero. If the concentration is higher in the protected area than at the output of the filter system, there is in-leakage and the in-leakage can be quantified by the difference.Sampling was performed using state-of-the-art Brookhaven Atmospheric Tracer Samplers (BATS) air sampling equipment and analysis performed on Brookhaven National Laboratory (BNL) dedicated PFT analytical systems. In the Alpha test two tracers PMCH and mcPDCH were used to determine in-leakage into the control building. The analytical system was tuned to maximize sensitivity after initial analysis of the Alpha test. The increased sensitivity permitted accurate quantification of five

  12. Industrial tracer application in people's republic of china

    International Nuclear Information System (INIS)

    Sun Maoyi

    1987-01-01

    A number of important applications of radioisotopes and their compounds used as tracers in petroleum industry, metallurgical industry, mechanical industry, chemical industry, electronic industry, hydrology and water conservancy in China are introduced in this paper. And the tracer technique applied to entomology is also mentioned. The industrial tracer applications are successful and beneficial in People's Republic of China from the examples given. (author)

  13. Effect of coexistent hydrogen isotopes on tracer diffusion of tritium in alpha phase of group-V metal-hydrogen systems

    International Nuclear Information System (INIS)

    Sakamoto, Kan; Hashizume, Kenichi; Sugisaki, Masayasu

    2009-01-01

    Tracer diffusion coefficients of tritium in the alpha phase of group-V metal-hydrogen systems, α-MH(D)xTy (M=V and Ta; x>>y), were measured in order to clarify the effects of coexistent hydrogen isotopes on the tritium diffusion behavior. The hydrogen concentration dependence of such behavior and the effects of the coexistent hydrogen isotopes (protium and deuterium) were determined. The results obtained in the present (for V and Ta) and previous (for Nb) studies revealed that tritium diffusion was definitely dependent on hydrogen concentration but was not so sensitive to the kind of coexistent hydrogen isotopes. By summarizing those data, it was found that the hydrogen concentration dependence of the tracer diffusion coefficient of tritium in the alpha phase of group-V metals could be roughly expressed by a single empirical curve. (author)

  14. Journal: A Review of Some Tracer-Test Design Equations for ...

    Science.gov (United States)

    Determination of necessary tracer mass, initial sample-collection time, and subsequent sample-collection frequency are the three most difficult aspects to estimate for a proposed tracer test prior to conducting the tracer test. To facilitate tracer-mass estimation, 33 mass-estimation equations are reviewed here, 32 of which were evaluated using previously published tracer-test design examination parameters. Comparison of the results produced a wide range of estimated tracer mass, but no means is available by which one equation may be reasonably selected over the others. Each equation produces a simple approximation for tracer mass. Most of the equations are based primarily on estimates or measurements of discharge, transport distance, and suspected transport times. Although the basic field parameters commonly employed are appropriate for estimating tracer mass, the 33 equations are problematic in that they were all probably based on the original developers' experience in a particular field area and not necessarily on measured hydraulic parameters or solute-transport theory. Suggested sampling frequencies are typically based primarily on probable transport distance, but with little regard to expected travel times. This too is problematic in that tends to result in false negatives or data aliasing. Simulations from the recently developed efficient hydrologic tracer-test design methodology (EHTD) were compared with those obtained from 32 of the 33 published tracer-

  15. Dosimetry of 64Cu-DOTA-AE105, a PET tracer for uPAR imaging

    DEFF Research Database (Denmark)

    Persson, Morten; El Ali, Henrik H.; Binderup, Tina

    2014-01-01

    64Cu-DOTA-AE105 is a novel positron emission tomography (PET) tracer specific to the human urokinase-type plasminogen activator receptor (uPAR). In preparation of using this tracer in humans, as a new promising method to distinguish between indolent and aggressive cancers, we have performed PET......, liver, kidney, spleen, intestine, muscle, bone and bladder. The activity concentrations in the mentioned organs [%ID/g] were used for the dosimetry calculation. The %ID/g of each organ at 1, 4.5 and 22h was scaled to human value based on a difference between organ and body weights. The scaled values...

  16. Tracer tests Wairakei

    International Nuclear Information System (INIS)

    McCabe, W.J.; Manning, M.R.; Barry, B.J.

    1980-07-01

    The report summarises the radioactive tracer tests, using iodine-131 and bromine-82, made in the Wairakei geothermal field over the period 1978-80. Injection of tracer into three wells with strong cool water downflows at about 300-400m below ground level, produced strong rapid responses from the only deep wells feeding from about 800-1000m and lying in the south-westerly direction from the injection wells, i.e. parallel to the fault planes. Shallower wells, even though in some cases much closer to the injection well, reacted much more slowly. Velocities, as measured by peak arrival times, as high as 22m/h over 200m and 11m/h over 650m, were found. The flow patterns for the cool water feeds to the production area are discussed

  17. Estimation of Fracture Porosity in an Unsaturated Fractured Welded Tuff Using Gas Tracer Testing

    International Nuclear Information System (INIS)

    B.M. Freifeild

    2001-01-01

    Kinematic fracture porosity is an important hydrologic transport parameter for predicting the potential of rapid contaminant migration through fractured rock. The transport velocity of a solute moving within a fracture network is inversely related to the fracture porosity. Since fracture porosity is often one or two orders of magnitude smaller than matrix porosity, and fracture permeability is often orders of magnitude greater than matrix permeability, solutes may travel significantly faster in the fracture network than in the surrounding matrix. This dissertation introduces a new methodology for conducting gas tracer tests using a field portable mass spectrometer along with analytical tools for estimating fracture porosity using the measured tracer concentration breakthrough curves. Field experiments were conducted at Yucca Mountain, Nevada, consisting of air-permeability transient testing and gas-tracer-transport tests. The experiments were conducted from boreholes drilled within an underground tunnel as part of an investigation of rock mass hydrological behavior. Air-permeability pressure transients, recorded during constant mass flux injections, have been analyzed using a numerical inversion procedure to identify fracture permeability and porosity. Dipole gas tracer tests have also been conducted from the same boreholes used for air-permeability testing. Mass breakthrough data has been analyzed using a random walk particle-tracking model, with a dispersivity that is a function of the advective velocity. The estimated fracture porosity using the tracer test and air-injection test data ranges from .001 to .015. These values are an order of magnitude greater than the values estimated by others using hydraulically estimated fracture apertures. The estimates of porosity made using air-permeability test data are shown to be highly sensitive to formation heterogeneity. Uncertainty analyses performed on the gas tracer test results show high confidence in the parameter

  18. Estimation of Fracture Porosity in an Unsaturated Fractured Welded Tuff Using Gas Tracer Testing

    Energy Technology Data Exchange (ETDEWEB)

    B.M. Freifeild

    2001-10-18

    Kinematic fracture porosity is an important hydrologic transport parameter for predicting the potential of rapid contaminant migration through fractured rock. The transport velocity of a solute moving within a fracture network is inversely related to the fracture porosity. Since fracture porosity is often one or two orders of magnitude smaller than matrix porosity, and fracture permeability is often orders of magnitude greater than matrix permeability, solutes may travel significantly faster in the fracture network than in the surrounding matrix. This dissertation introduces a new methodology for conducting gas tracer tests using a field portable mass spectrometer along with analytical tools for estimating fracture porosity using the measured tracer concentration breakthrough curves. Field experiments were conducted at Yucca Mountain, Nevada, consisting of air-permeability transient testing and gas-tracer-transport tests. The experiments were conducted from boreholes drilled within an underground tunnel as part of an investigation of rock mass hydrological behavior. Air-permeability pressure transients, recorded during constant mass flux injections, have been analyzed using a numerical inversion procedure to identify fracture permeability and porosity. Dipole gas tracer tests have also been conducted from the same boreholes used for air-permeability testing. Mass breakthrough data has been analyzed using a random walk particle-tracking model, with a dispersivity that is a function of the advective velocity. The estimated fracture porosity using the tracer test and air-injection test data ranges from .001 to .015. These values are an order of magnitude greater than the values estimated by others using hydraulically estimated fracture apertures. The estimates of porosity made using air-permeability test data are shown to be highly sensitive to formation heterogeneity. Uncertainty analyses performed on the gas tracer test results show high confidence in the parameter

  19. Estimation of fracture porosity in an unsaturated fractured welded tuff using gas tracer testing

    Energy Technology Data Exchange (ETDEWEB)

    Freifeld, Barry Mark [Univ. of California, Berkeley, CA (United States)

    2001-12-01

    Kinematic fracture porosity is an important hydrologic transport parameter for predicting the potential of rapid contaminant migration through fractured rock. The transport velocity of a solute moving within a fracture network is inversely related to the fracture porosity. Since fracture porosity is often one or two orders of magnitude smaller than matrix porosity, and fracture permeability is often orders of magnitude greater than matrix permeability, solutes may travel significantly faster in the fracture network than in the surrounding matrix. This dissertation introduces a new methodology for conducting gas tracer tests using a field portable mass spectrometer along with analytical tools for estimating fracture porosity using the measured tracer concentration breakthrough curves. Field experiments were conducted at Yucca Mountain, Nevada, consisting of air-permeability transient testing and gas-tracer-transport tests. The experiments were conducted from boreholes drilled within an underground tunnel as part of an investigation of rock mass hydrological behavior. Air-permeability pressure transients, recorded during constant mass flux injections, have been analyzed using a numerical inversion procedure to identify fracture permeability and porosity. Dipole gas tracer tests have also been conducted from the same boreholes used for air-permeability testing. Mass breakthrough data has been analyzed using a random walk particle-tracking model, with a dispersivity that is a function of the advective velocity. The estimated fracture porosity using the tracer test and air-injection test data ranges from .001 to .015. These values are an order of magnitude greater than the values estimated by others using hydraulically estimated fracture apertures. The estimates of porosity made using air-permeability test data are shown to be highly sensitive to formation heterogeneity. Uncertainty analyses performed on the gas tracer test results show high confidence in the parameter

  20. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specification

    Science.gov (United States)

    2010-07-01

    ... Measurements Required, and Maximum Discrepancy Specification C Table C-1 to Subpart C of Part 53 Protection of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges..., June 22, 2010, table C-1 to subpart C was revised, effective Aug. 23, 2010. For the convenience of the...

  1. TRACER - TRACING AND CONTROL OF ENGINEERING REQUIREMENTS

    Science.gov (United States)

    Turner, P. R.

    1994-01-01

    TRACER (Tracing and Control of Engineering Requirements) is a database/word processing system created to document and maintain the order of both requirements and descriptive material associated with an engineering project. A set of hierarchical documents are normally generated for a project whereby the requirements of the higher level documents levy requirements on the same level or lower level documents. Traditionally, the requirements are handled almost entirely by manual paper methods. The problem with a typical paper system, however, is that requirements written and changed continuously in different areas lead to misunderstandings and noncompliance. The purpose of TRACER is to automate the capture, tracing, reviewing, and managing of requirements for an engineering project. The engineering project still requires communications, negotiations, interactions, and iterations among people and organizations, but TRACER promotes succinct and precise identification and treatment of real requirements separate from the descriptive prose in a document. TRACER permits the documentation of an engineering project's requirements and progress in a logical, controllable, traceable manner. TRACER's attributes include the presentation of current requirements and status from any linked computer terminal and the ability to differentiate headers and descriptive material from the requirements. Related requirements can be linked and traced. The program also enables portions of documents to be printed, individual approval and release of requirements, and the tracing of requirements down into the equipment specification. Requirement "links" can be made "pending" and invisible to others until the pending link is made "binding". Individuals affected by linked requirements can be notified of significant changes with acknowledgement of the changes required. An unlimited number of documents can be created for a project and an ASCII import feature permits existing documents to be incorporated

  2. Tracer migration experiments in the Stripa mine 1980-1991

    International Nuclear Information System (INIS)

    Birgersson, L.; Widen, H.; Aagren, T.; Neretnieks, I.

    1992-05-01

    During more than 10 years, tracer experiments have been performed in the Stripa mine as part of the Stripa project to investigate the properties of both 'average' fractured rock and fracture zones. Experiments have been performed that have ranged from a few decimeters, to examine the diffusion into the rock matrix, up to tracer migration to a drift more than 50 meters from the injection point. This report compiles the results and experience that have been gained from all these tracer experiments. The experiments that are described in this report are: * The in-situ diffusion experiment where simultaneous flow and diffusion of tracers in undisturbed rock were studied over more than 3 years to validate diffusivities obtained under laboratory conditions. * Migration in a single fracture where water flow distribution and tracer transport were studied using both conservative and sorbing tracers over migration distances up to 10 meters. * The 3-D migration experiment where water inflow and tracer transport to a drift covered with 350 plastic sheet were investigated to get information on flow porosity, dispersion and channeling. The transport distances were between 10 and 56 meters from the injection points to the drift. * The channeling experiments in which the aim was to examine the channeling properties of single fractures in detail. Pressure pulse tests and tracer experiments were performed over a distances of 2 meters. * The tracer migration experiment in the validation drift where the tracer were injected mainly in a fracture zone and the collection was inside both a drift covered with plastic sheets similar to in the 3-D experiment as well as in a borehole. The distances between injection and sampling location were between 10 and 25 meters. (57 refs.) (au)

  3. Radioisotope tracer applications in industry

    International Nuclear Information System (INIS)

    Rao, S.M.

    1987-01-01

    Radioisotope tracers have many advantages in industrial trouble-shooting and studies on process kinetics. The applications are mainly of two types: one leading to qualitative (Yes or No type) information and the other to quantitative characterisation of flow processes through mass balance considerations and flow models. ''Yes or No'' type methods are mainly used for leakage and blockage locations in pipelines and in other industrial systems and also for location of water seepage zones in oil wells. Flow measurements in pipelines and mercury inventory in electrolytic cells are good examples of tracer methods using the mass balance approach. Axial dispersion model and Tanks-in-Series model are the two basic flow models commonly used with tracer methods for the characterisation of kinetic processes. Examples include studies on flow processes in sugar crystallisers as well as in a precalcinator in a cement plant. (author). 18 figs

  4. Elements and inorganic ions as source tracers in recent Greenland snow

    Science.gov (United States)

    Lai, Alexandra M.; Shafer, Martin M.; Dibb, Jack E.; Polashenski, Chris M.; Schauer, James J.

    2017-09-01

    Atmospheric transport of aerosols leads to deposition of impurities in snow, even in areas of the Arctic as remote as Greenland. Major ions (e.g. Na+, Ca2+, NH4+, K+, SO42-) are frequently used as tracers for common aerosol sources (e.g. sea spray, dust, biomass burning, anthropogenic emissions). Trace element data can supplement tracer ion data by providing additional information about sources. Although many studies have considered either trace elements or major ions, few have reported both. This study determined total and water-soluble concentrations of 31 elements (Al, As, Ca, Cd, Ce, Co, Cr, Dy, Eu, Fe, Gd, K, La, Mg, Mn, Na, Nb, Nd, Pb, Pr, S, Sb, Si, Sm, Sn, Sr, Ti, V, U, Y, Zn) in shallow snow pits at 22 sampling sites in Greenland, along a transect from Summit Station to sites in the northwest. Black carbon (BC) and inorganic ions were measured in colocated samples. Sodium, which is typically used as a tracer of sea spray, did not appear to have any non-marine sources. The rare earth elements, alkaline earth elements (Mg, Ca, Sr), and other crustal elements (Fe, Si, Ti, V) were not enriched above crustal abundances relative to Al, indicating that these elements are primarily dust sourced. Calculated ratios of non-sea salt Ca (nssCa) to estimated dust mass affirm the use of nssCa as a dust tracer, but suggest up to 50% uncertainty in that estimate in the absence of other crustal element data. Crustal enrichment factors indicated that As, Cd, Pb, non-sea-salt S, Sb, Sn, and Zn were enriched in these samples, likely by anthropogenic sources. Principal component analysis indicated more than one crustal factor, and a variety of factors related to anthropogenically enriched elements. Analysis of trace elements alongside major tracer ions does not change interpretation of ion-based source attribution for sources that are well-characterized by ions, but is valuable for assessing uncertainty in source attribution and identifying sources not represented by major ions.

  5. Tracers of cancer cells in nuclear oncology

    International Nuclear Information System (INIS)

    Tamgac, F.; Baillet, G.; Moretti, J.L.; Safi, N.; Weinmann, P.; Beco, V. de

    1997-01-01

    Evaluating the extent of disease is important in planning cancer treatment. Different types of tracers are used in vivo to diagnose tumors and these tracers can give supplementary information on the differentiation degree of tumors and response to therapy. (authors)

  6. Statistical atmospheric inversion of local gas emissions by coupling the tracer release technique and local-scale transport modelling: a test case with controlled methane emissions

    Directory of Open Access Journals (Sweden)

    S. Ars

    2017-12-01

    Full Text Available This study presents a new concept for estimating the pollutant emission rates of a site and its main facilities using a series of atmospheric measurements across the pollutant plumes. This concept combines the tracer release method, local-scale atmospheric transport modelling and a statistical atmospheric inversion approach. The conversion between the controlled emission and the measured atmospheric concentrations of the released tracer across the plume places valuable constraints on the atmospheric transport. This is used to optimise the configuration of the transport model parameters and the model uncertainty statistics in the inversion system. The emission rates of all sources are then inverted to optimise the match between the concentrations simulated with the transport model and the pollutants' measured atmospheric concentrations, accounting for the transport model uncertainty. In principle, by using atmospheric transport modelling, this concept does not strongly rely on the good colocation between the tracer and pollutant sources and can be used to monitor multiple sources within a single site, unlike the classical tracer release technique. The statistical inversion framework and the use of the tracer data for the configuration of the transport and inversion modelling systems should ensure that the transport modelling errors are correctly handled in the source estimation. The potential of this new concept is evaluated with a relatively simple practical implementation based on a Gaussian plume model and a series of inversions of controlled methane point sources using acetylene as a tracer gas. The experimental conditions are chosen so that they are suitable for the use of a Gaussian plume model to simulate the atmospheric transport. In these experiments, different configurations of methane and acetylene point source locations are tested to assess the efficiency of the method in comparison to the classic tracer release technique in coping

  7. Statistical atmospheric inversion of local gas emissions by coupling the tracer release technique and local-scale transport modelling: a test case with controlled methane emissions

    Science.gov (United States)

    Ars, Sébastien; Broquet, Grégoire; Yver Kwok, Camille; Roustan, Yelva; Wu, Lin; Arzoumanian, Emmanuel; Bousquet, Philippe

    2017-12-01

    This study presents a new concept for estimating the pollutant emission rates of a site and its main facilities using a series of atmospheric measurements across the pollutant plumes. This concept combines the tracer release method, local-scale atmospheric transport modelling and a statistical atmospheric inversion approach. The conversion between the controlled emission and the measured atmospheric concentrations of the released tracer across the plume places valuable constraints on the atmospheric transport. This is used to optimise the configuration of the transport model parameters and the model uncertainty statistics in the inversion system. The emission rates of all sources are then inverted to optimise the match between the concentrations simulated with the transport model and the pollutants' measured atmospheric concentrations, accounting for the transport model uncertainty. In principle, by using atmospheric transport modelling, this concept does not strongly rely on the good colocation between the tracer and pollutant sources and can be used to monitor multiple sources within a single site, unlike the classical tracer release technique. The statistical inversion framework and the use of the tracer data for the configuration of the transport and inversion modelling systems should ensure that the transport modelling errors are correctly handled in the source estimation. The potential of this new concept is evaluated with a relatively simple practical implementation based on a Gaussian plume model and a series of inversions of controlled methane point sources using acetylene as a tracer gas. The experimental conditions are chosen so that they are suitable for the use of a Gaussian plume model to simulate the atmospheric transport. In these experiments, different configurations of methane and acetylene point source locations are tested to assess the efficiency of the method in comparison to the classic tracer release technique in coping with the distances

  8. Simulation of diffusion in concentrated lattice gases

    International Nuclear Information System (INIS)

    Kehr, K.W.

    1986-01-01

    Recently the diffusion of particles in lattice gases was studied extensively by theoretical methods and numerical simulations. This paper reviews work on collective and, in particular, on tracer diffusion. The diffusion of tagged particles is characterized by a correlation factor whose behavior as a function of concentration is now well understood. Also the detailed kinetics of the tracer transitions was investigated. A special case is the one-dimensional lattice gas where the tracer diffusion coefficient vanishes. An interesting extension is the case of tagged atoms with a different transition rate. This model allows to study various physical situations, including impurity diffusion, percolation, and diffusion in partially blocked lattices. Finally some recent work on diffusion in lattice gases under the influence of a drift field will be reported. (author)

  9. Insights into controls on hexavalent chromium in groundwater provided by environmental tracers, Sacramento Valley, California, USA

    Science.gov (United States)

    Manning, Andrew H.; Mills, Christopher T.; Morrison, Jean M.; Ball, Lyndsay B.

    2015-01-01

    Environmental tracers are useful for determining groundwater age and recharge source, yet their application in studies of geogenic Cr(VI) in groundwater has been limited. Environmental tracer data from 166 wells located in the Sacramento Valley, northern California, were interpreted and compared to Cr concentrations to determine the origin and age of groundwater with elevated Cr(VI), and better understand where Cr(VI) becomes mobilized and how it evolves along flowpaths. In addition to major ion and trace element concentrations, the dataset includes δ18O, δ2H, 3H concentration, 14C activity (of dissolved inorganic C), δ13C, 3He/4He ratio, and noble gas concentrations (He, Ne, Ar, Kr, Xe). Noble gas recharge temperatures (NGTs) were computed, and age-related tracers were interpreted in combination to constrain the age distribution in samples and sort them into six different age categories spanning from 10,000 yr old. Nearly all measured Cr is in the form of Cr(IV). Concentrations range from 3 mg L−1), and commonly have δ18O values enriched relative to local precipitation. These samples likely contain irrigation water and are elevated due to accelerated mobilization of Cr(VI) in the unsaturated zone (UZ) in irrigated areas. Group 2 samples are from throughout the valley and typically contain water 1000–10,000 yr old, have δ18O values consistent with local precipitation, and have unexpectedly warm NGTs. Chromium(VI) concentrations in Group 2 samples may be elevated for multiple reasons, but the hypothesis most consistent with all available data (notably, the warm NGTs) is a relatively long UZ residence time due to recharge through a deep UZ near the margin of the basin. A possible explanation for why Cr(VI) may be primarily mobilized in the UZ rather than farther along flowpaths in the oxic portion of the saturated zone is more dynamic cycling of Mn in the UZ due to transient moisture and redox conditions.

  10. PET tracers for somatostatin receptor imaging of neuroendocrine tumors

    DEFF Research Database (Denmark)

    Johnbeck, Camilla Bardram; Knigge, Ulrich; Kjær, Andreas

    2014-01-01

    Neuroendocrine tumors have shown rising incidence mainly due to higher clinical awareness and better diagnostic tools over the last 30 years. Functional imaging of neuroendocrine tumors with PET tracers is an evolving field that is continuously refining the affinity of new tracers in the search...... these PET tracers further....

  11. Biological tracer for waste site characterization

    International Nuclear Information System (INIS)

    Strong-Gunderson, J.

    1995-01-01

    Remediating hazardous waste sites requires detailed site characterization. In groundwater remediation, characterizing the flow paths and velocity is a major objective. Various tracers have been used for measuring groundwater velocity and transport of contaminants, colloidal particles, and bacteria and nutrients. The conventional techniques use dissolved solutes, dyes. and gases to estimate subsurface transport pathways. These tracers can provide information on transport and diffusion into the matrix, but their estimates for groundwater flow through fractured regions are very conservative. Also, they do not have the same transport characteristics as bacteria and suspended colloid tracers, both of which must be characterized for effective in-place remediation. Bioremediation requires understanding bacterial transport and nutrient distribution throughout the acquifer, knowledge of contaminants s mobile colloidal particles is just essential

  12. Process Analysis in Chemical Plant by Means of Radioactive Tracers

    Energy Technology Data Exchange (ETDEWEB)

    Hirayama, T.; Hamada, K.; Osada, K. [Showa Denko K.K., Tokyo (Japan)

    1967-06-15

    Following the movement of solids and fluids is important in chemical processes to determine mixing efficiency and residence time. Since it is necessary to follow many complex substances such as raw materials, intermediates and reactants in plant investigations, it is often necessary to ascertain whether the behaviour of the radioisotope tracer and the substance to be traced are identical. The most difficult problem is to determine the best method of labelling, a factor which is a substantial key to the success of an experiment. Usually, there are three labelling techniques: radioisotope labelling, pre-.activation of the material and post-activation of the material. This paper deals with practical examples of the double-tracer technique, a combination of conventional radioisotope labelling and post-activation methods by means of activation analysis. In process analysis by means of tracers, a practical measurement method should also be devised and developed for each experiment. Phosphorus-32 and gold (non-radioactive) were used to measure retention time in a carbon-black plant. The radioisotope was pumped into a feed-stock pipe positioned before the reactor and samples were taken from each process of the plant, including the bag filter, mixer and product tank. After sampling from each step of the process, {sup 32}P in a semi-infinite powder sample was measured in situ by beta counting, and the gold was measured by gamma counting after activating the sample in a reactor. The experiment showed that both tracers had the same residence time, which was shorter than expected. Useful data were also obtained from the dispersion pattern of the material flow for future operation controls, including the time required to change from one grade of product to another. Practical tracer techniques to measure mixing characteristics in high-speed gas flows using {sup 85}Kr have been developed. A study of the measurement method was conducted by calculating the differential values of

  13. Tracer applications in oil reservoirs in Brazil

    International Nuclear Information System (INIS)

    Moreira, R.M.; Ferreira Pinto, A.M.

    2004-01-01

    Radiotracer applications in oil reservoirs in Brazil started in 1997 at the request of the State Oil Company (Petrobras) at the Carmoplois oilfield. 1 Ci of HTO was injected in a regular five-spot plot and the results obtained were quite satisfactory. Shortly after this test one other request asked for distinguishing the contribution of different injection wells to a production well. It was then realized that other tracers should be available. As a first choice 35 SCN - has been selected since it could be produced at CDTN. An alternative synthesis path was defined which shortened post-irradiation manipulations. The tracer was tested in core samples and a field injection, simultaneously with HTO, was carried out at the Buracica field; again the HTO performed well but 35 SCN - showed up well ahead. Presently the HTO applications are being done on a routine basis. All in all, four tests were performed (some are still ongoing), and the detection limits for both 3 H and 35 S were optimized by refining the sample preparation stage. Lanthanide complexes used as activable tracers are also an appealing option, however core tests performed so far with La-, Ce- and Eu-EDTA indicated some delay of the tracer, so other complexants such as DOTA are to be tried in further laboratory tests and in a field application. Thus, a deeper understanding of their complexation chemistry and carefully conducted tests must be performed before lanthanide complexes can be qualified as reliable oil reservoir tracers. More recently, Petrobras has been asking for partitioning tracers intended for SOR measurement

  14. Impact of biomass burning on urban air quality estimated by organic tracers: Guangzhou and Beijing as cases

    International Nuclear Information System (INIS)

    Qiaoqiao Wang; Min Shao; Ying Liu; Kuster, William; Goldan, Paul; Xiaohua Li; Yuan Liu; Sihua Lu

    2007-01-01

    The impacts of biomass burning have not been adequately studied in China. In this work, chemical compositions of volatile organic compounds and particulate organic matters were measured in August 2005 in Beijing and in October 2004 in Guangzhou city. The performance of several possible tracers for biomass burning is compared by using acetonitrile as a reference compound. The correlations between the possible tracers and acetonitrile show that the use of K + as a tracer could result in bias because of the existence of other K+ sources in urban areas, while chloromethane is not reliable due to its wide use as industrial chemical. The impact of biomass burning on air quality is estimated using acetonitrile and levoglucosan as tracers. The results show that the impact of biomass burning is ubiquitous in both suburban and urban Guangzhou, and the frequencies of air pollution episodes significantly influenced by biomass burning were 100% for Xinken and 58% for downtown Guangzhou city. Fortunately, the air quality in only 2 out of 22 days was partly impacted by biomass burning in August in Beijing, the month that 2008 Olympic games will take place. The quantitative contribution of biomass burning to ambient PM 2.5 concentrations in Guangzhou city was also estimated by the ratio of levoglocusan to PM 2.5 in both the ambient air and biomass burning plumes. The results show that biomass burning contributes 3.02013;16.8% and 4.02013;19.0% of PM 2.5 concentrations in Xinken and Guangzhou downtown, respectively. (Author)

  15. Impact of biomass burning on urban air quality estimated by organic tracers: Guangzhou and Beijing as cases

    Energy Technology Data Exchange (ETDEWEB)

    Qiaoqiao Wang; Min Shao; Ying Liu [State Joint Key Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences, Peking University, Beijing 100871, (China); Kuster, William; Goldan, Paul [Earth System Research Laboratory, U.S. Department of Commerce, Boulder, CO 80305, (United States); Xiaohua Li; Yuan Liu; Sihua Lu [State Joint Key Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences, Peking University, Beijing 100871, (China)

    2007-12-15

    The impacts of biomass burning have not been adequately studied in China. In this work, chemical compositions of volatile organic compounds and particulate organic matters were measured in August 2005 in Beijing and in October 2004 in Guangzhou city. The performance of several possible tracers for biomass burning is compared by using acetonitrile as a reference compound. The correlations between the possible tracers and acetonitrile show that the use of K{sup +} as a tracer could result in bias because of the existence of other K+ sources in urban areas, while chloromethane is not reliable due to its wide use as industrial chemical. The impact of biomass burning on air quality is estimated using acetonitrile and levoglucosan as tracers. The results show that the impact of biomass burning is ubiquitous in both suburban and urban Guangzhou, and the frequencies of air pollution episodes significantly influenced by biomass burning were 100% for Xinken and 58% for downtown Guangzhou city. Fortunately, the air quality in only 2 out of 22 days was partly impacted by biomass burning in August in Beijing, the month that 2008 Olympic games will take place. The quantitative contribution of biomass burning to ambient PM{sub 2.5} concentrations in Guangzhou city was also estimated by the ratio of levoglocusan to PM{sub 2.5} in both the ambient air and biomass burning plumes. The results show that biomass burning contributes 3.02013;16.8% and 4.02013;19.0% of PM{sub 2.5} concentrations in Xinken and Guangzhou downtown, respectively. (Author)

  16. Impact of biomass burning on urban air quality estimated by organic tracers: Guangzhou and Beijing as cases

    Energy Technology Data Exchange (ETDEWEB)

    Qiaoqiao Wang; Min Shao; Ying Liu [State Joint Key Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences, Peking University, Beijing 100871, (China); Kuster, William; Goldan, Paul [Earth System Research Laboratory, U.S. Department of Commerce, Boulder, CO 80305, (United States); Xiaohua Li; Yuan Liu; Sihua Lu [State Joint Key Laboratory of Environmental Simulation and Pollution Control, College of Environmental Sciences, Peking University, Beijing 100871, (China)

    2007-12-15

    The impacts of biomass burning have not been adequately studied in China. In this work, chemical compositions of volatile organic compounds and particulate organic matters were measured in August 2005 in Beijing and in October 2004 in Guangzhou city. The performance of several possible tracers for biomass burning is compared by using acetonitrile as a reference compound. The correlations between the possible tracers and acetonitrile show that the use of K{sup +} as a tracer could result in bias because of the existence of other K+ sources in urban areas, while chloromethane is not reliable due to its wide use as industrial chemical. The impact of biomass burning on air quality is estimated using acetonitrile and levoglucosan as tracers. The results show that the impact of biomass burning is ubiquitous in both suburban and urban Guangzhou, and the frequencies of air pollution episodes significantly influenced by biomass burning were 100% for Xinken and 58% for downtown Guangzhou city. Fortunately, the air quality in only 2 out of 22 days was partly impacted by biomass burning in August in Beijing, the month that 2008 Olympic games will take place. The quantitative contribution of biomass burning to ambient PM{sub 2.5} concentrations in Guangzhou city was also estimated by the ratio of levoglocusan to PM{sub 2.5} in both the ambient air and biomass burning plumes. The results show that biomass burning contributes 3.02013;16.8% and 4.02013;19.0% of PM{sub 2.5} concentrations in Xinken and Guangzhou downtown, respectively. (Author).

  17. Tracer dispersion in planar multipole flows

    International Nuclear Information System (INIS)

    Koplik, J.; Redner, S.; Hinch, E.J.

    1994-01-01

    We study the motion of passive Brownian tracer particles in steady two-dimensional potential flows between sources and sinks. Our primary focus is understanding the long-time properties of the transit time probability distribution for the tracer to reach the sink p(t) and the influence of the flow geometry on this probability. A variety of illustrative case studies is considered. For radial potential flow in an annular region, competition between convection and diffusion leads to nonuniversal decay of the transit time probability. Dipolar and higher multipole flows are found to exhibit generic features, such as a power-law decay in p(t) with an exponent determined by the multipole moment, an exponential cutoff related to stagnation points, and a ''shoulder'' in p(t) that is related to reflection from the system boundaries. For spatially extended sinks, it is also shown that the spatial distribution of the collected tracer is independent of the overall magnitude of the flow field and that p(t) decays as a power law with a geometry-dependent exponent. Our results may offer the possibility of using tracer measurements to characterize the flow geometry of porous media

  18. Bromide as chemical tracer to measure the liquid effluent flow at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Silva, Douglas B.; Faustino, Mainara G.; Monteiro, Lucilena R.; Cotrim, Marycel E.B.; Pires, Maria Aparecida F.

    2013-01-01

    Due to recent changes in CONAMA Resolution 357, which occurred through the publication of Resolution 430, on May 13, 2011 that now set standards about the effluent release, IPEN-CNEN/SP initiated several actions to improve the Environmental Monitoring Program (PMA-Q) of stable chemical compounds. Besides various parameters (physical and chemical) established by CONAMA, the submission of an annual pollution inventory report became necessary. The liquid effluent flow measurement is required to implement this inventory. Thereby, this paper describes a study that uses bromide as a chemical tracer. This paper presents the results of 6 tracer releases in IPEN wastewater collection network between 2011 and 2012. Two tracer releases designs were performed: single pulse and continuous releases performed with 1 to 6 hours duration, done by using one single piston pump manufactured by DIONEX. After the release, one fraction of the effluent was collected every 15 minutes at IPEN effluent monitoring station. The tracer concentration in the effluent was analyzed by ion chromatography and flow was calculated considering the dilution in the system and pump flow set up for the release. The flow values were measured in 6 events were determined and evaluated as per Brazilian regulation requirements. Experimental designs to be implemented during 2013 monitoring were also discussed in this paper, contributing to legal compliance and to improve IPEN's Environmental Monitoring Program for stable chemical compounds (PMA-Q). (author)

  19. New radioactive tracers can help find cause of jaundice

    International Nuclear Information System (INIS)

    Carrard, G.

    1987-01-01

    Radioactive tracers for the investigation of a condition known as persistent jaundice of the newborn, have been designed, prepared and tested at ANSTO. The tracers are chemical compounds of the radioactive elements gallium-67 and indium-111. They given lower radiation doses than the conventional radioactive tracer, iodine-131, used in these studies

  20. Maximum entropy deconvolution of low count nuclear medicine images

    International Nuclear Information System (INIS)

    McGrath, D.M.

    1998-12-01

    Maximum entropy is applied to the problem of deconvolving nuclear medicine images, with special consideration for very low count data. The physics of the formation of scintigraphic images is described, illustrating the phenomena which degrade planar estimates of the tracer distribution. Various techniques which are used to restore these images are reviewed, outlining the relative merits of each. The development and theoretical justification of maximum entropy as an image processing technique is discussed. Maximum entropy is then applied to the problem of planar deconvolution, highlighting the question of the choice of error parameters for low count data. A novel iterative version of the algorithm is suggested which allows the errors to be estimated from the predicted Poisson mean values. This method is shown to produce the exact results predicted by combining Poisson statistics and a Bayesian interpretation of the maximum entropy approach. A facility for total count preservation has also been incorporated, leading to improved quantification. In order to evaluate this iterative maximum entropy technique, two comparable methods, Wiener filtering and a novel Bayesian maximum likelihood expectation maximisation technique, were implemented. The comparison of results obtained indicated that this maximum entropy approach may produce equivalent or better measures of image quality than the compared methods, depending upon the accuracy of the system model used. The novel Bayesian maximum likelihood expectation maximisation technique was shown to be preferable over many existing maximum a posteriori methods due to its simplicity of implementation. A single parameter is required to define the Bayesian prior, which suppresses noise in the solution and may reduce the processing time substantially. Finally, maximum entropy deconvolution was applied as a pre-processing step in single photon emission computed tomography reconstruction of low count data. Higher contrast results were

  1. Fluorinated tracers for imaging cancer with positron emission tomography

    International Nuclear Information System (INIS)

    Couturier, Olivier; Chatal, Jean-Francois; Luxen, Andre; Vuillez, Jean-Philippe; Rigo, Pierre; Hustinx, Roland

    2004-01-01

    2-[ 18 F]fluoro-2-deoxy-d-glucose (FDG) is currently the only fluorinated tracer used in routine clinical positron emission tomography (PET). Fluorine-18 is considered the ideal radioisotope for PET imaging owing to the low positron energy (0.64 MeV), which not only limits the dose rate to the patient but also results in a relatively short range of emission in tissue, thereby providing high-resolution images. Further, the 110-min physical half-life allows for high-yield radiosynthesis, transport from the production site to the imaging site and imaging protocols that may span hours, which permits dynamic studies and assessment of potentially fairly slow metabolic processes. The synthesis of fluorinated tracers as an alternative to FDG was initially tested using nucleophilic fluorination of the molecule, as performed when radiolabelling with iodine-124 or bromide-76. However, in addition to being long, with multiple steps, this procedure is not recommended for bioactive molecules containing reactive groups such as amine or thiol groups. Radiochemical yields are also often low. More recently, radiosynthesis from prosthetic group precursors, which allows easier radiolabelling of biomolecules, has led to the development of numerous fluorinated tracers. Given the wide availability of 18 F, such tracers may well develop into important routine tracers. This article is a review of the literature concerning fluorinated radiotracers recently developed and under investigation for possible PET imaging in cancer patients. Two groups can be distinguished. The first includes ''generalist'' tracers, i.e. tracers amenable to use in a wide variety of tumours and indications, very similar in this respect to FDG. These are tracers for non-specific cell metabolism, such as protein synthesis, amino acid transport, nucleic acid synthesis or membrane component synthesis. The second group consists of ''specific'' tracers for receptor expression (i.e. oestrogens or somatostatin), cell

  2. A comparison between tracer gas and aerosol particles distribution indoors: The impact of ventilation rate, interaction of airflows, and presence of objects

    DEFF Research Database (Denmark)

    Bivolarova, Mariya Petrova; Ondráček, Jakub; Melikov, Arsen Krikor

    2017-01-01

    for the exposure to all different-sized test particles. A change in the ventilation rate did not affect the difference in concentration distribution between tracer gas and larger particle sizes. Increasing the room surface area did not influence the similarity in the dispersion of the aerosol particles...... room with mixing ventilation. Three layouts were arranged: an empty room, an office room with an occupant sitting in front of a table, and a single-bed hospital room. The room occupant was simulated by a thermal manikin. Monodisperse particles of three sizes (0.07, 0.7, and 3.5 μm) and nitrous oxide...... tracer gas were generated simultaneously at the same location in the room. The particles and gas concentrations were measured in the bulk room air, in the breathing zone of the manikin, and in the exhaust air. Within the breathing zone of the sitting occupant, the tracer gas emerged as reliable predictor...

  3. Defining optimal tracer activities in pediatric oncologic whole-body "1"8F-FDG-PET/MRI

    International Nuclear Information System (INIS)

    Gatidis, Sergios; Schmidt, Holger; Nikolaou, Konstantin; Schwenzer, Nina F.; Schaefer, Juergen F.; La Fougere, Christian

    2016-01-01

    To explore the feasibility of reducing administered tracer activities and to assess optimal activities for combined "1"8F-FDG-PET/MRI in pediatric oncology. 30 "1"8F-FDG-PET/MRI examinations were performed on 24 patients with known or suspected solid tumors (10 girls, 14 boys, age 12 ± 5.6 [1-18] years; PET scan duration: 4 min per bed position). Low-activity PET images were retrospectively simulated from the originally acquired data sets using randomized undersampling of list mode data. PET data of different simulated administered activities (0.25-2.5 MBq/kg body weight) were reconstructed with or without point spread function (PSF) modeling. Mean and maximum standardized uptake values (SUV_m_e_a_n and SUV_m_a_x) as well as SUV variation (SUV_v_a_r) were measured in physiologic organs and focal FDG-avid lesions. Detectability of organ structures and of focal "1"8F-FDG-avid lesions as well as the occurrence of false-positive PET lesions were assessed at different simulated tracer activities. Subjective image quality steadily declined with decreasing tracer activities. Compared to the originally acquired data sets, mean relative deviations of SUV_m_e_a_n and SUV_m_a_x were below 5 % at "1"8F-FDG activities of 1.5 MBq/kg or higher. Over 95 % of anatomic structures and all pathologic focal lesions were detectable at 1.5 MBq/kg "1"8F-FDG. Detectability of anatomic structures and focal lesions was significantly improved using PSF. No false-positive focal lesions were observed at tracer activities of 1 MBq/kg "1"8F-FDG or higher. Administration of "1"8F-FDG activities of 1.5 MBq/kg is, thus, feasible without obvious diagnostic shortcomings, which is equivalent to a dose reduction of more than 50 % compared to current recommendations. Significant reduction in administered "1"8F-FDG tracer activities is feasible in pediatric oncologic PET/MRI. Appropriate activities of "1"8F-FDG or other tracers for specific clinical questions have to be further established in selected

  4. The use of vitamins as tracer dyes for laser-induced fluorescence in liquid flow applications

    Science.gov (United States)

    Zähringer, Katharina

    2014-04-01

    Tracers commonly used in experimental flow studies are mostly nocuous to the environment and human health. Particularly, in large flow installations, this can become a problem. In this study, a solution of this problem is presented, based on using water-soluble vitamins. Five of them are examined here for their applicability in flow studies. Vitamins B2 and B6 turned out to be the most promising candidates, and the dependency of their fluorescence intensity on parameters like concentration, laser energy, temperature, and pH are determined for two commonly used laser excitation wavelengths (532, 355 nm). Two examples of application in a static mixer and a spray flow are shown and demonstrate the applicability of the vitamin tracers.

  5. LensEnt2: Maximum-entropy weak lens reconstruction

    Science.gov (United States)

    Marshall, P. J.; Hobson, M. P.; Gull, S. F.; Bridle, S. L.

    2013-08-01

    LensEnt2 is a maximum entropy reconstructor of weak lensing mass maps. The method takes each galaxy shape as an independent estimator of the reduced shear field and incorporates an intrinsic smoothness, determined by Bayesian methods, into the reconstruction. The uncertainties from both the intrinsic distribution of galaxy shapes and galaxy shape estimation are carried through to the final mass reconstruction, and the mass within arbitrarily shaped apertures are calculated with corresponding uncertainties. The input is a galaxy ellipticity catalog with each measured galaxy shape treated as a noisy tracer of the reduced shear field, which is inferred on a fine pixel grid assuming positivity, and smoothness on scales of w arcsec where w is an input parameter. The ICF width w can be chosen by computing the evidence for it.

  6. A mathematical model for the design and interpretation of tracer experiments intended to measure the T90 in estuarine coastal waters

    International Nuclear Information System (INIS)

    Suarez Antola, R.

    2006-07-01

    In highly stratified estuarine waters, with significant sediment loads, it is fairly difficult to predict the T90 , the time scale that characterizes the bacterial inactivation or death, using mathematical formulae, so that suitable experiments must be done using tracers to measure physical dilution and microbiological methods to measure bacterial disappearance or inactivation. The location and characteristics of a second sewage out fall for the city of Montevideo is being determined. In this framework, several experiments with tracers were done to measure the self-purifying capacity of the coastal waters at the selected site. Due to the difficulties in the design and interpretation of the measurements, special mathematical models were constructed and applied to help in obtaining a deeper understanding of the complex advection-dispersion-inactivation processes. In this report the construction and the solution of the equations of an analytical model that guided all the subsequent modelling activities is described. The tracer and the bacteria fields are obtained as products of a function of time and the horizontal coordinates by a series of decaying exponential functions of time weighted by functions of depth. The quotient between the bacteria concentration and the tracer concentration, that is commonly used to determine a global value of T90 , taking suitable average values after a long enough transient, is studied. A procedure that may be used to summarize the field of local inactivation times by a few parameters, determined by tracer experiments and microbiological measurements, is discussed. A half-empirical correlation formula between the T90 parameter and the main variables of the body of receiving waters is suggested from the results of tracer experiments and other sources of information. The advantages and limitations of the modelling approach used in this case are assessed and some possible improvements are briefly outlined

  7. A mathematical model for the design and interpretation of tracer experiments intended to measure the T90 in estuarine coastal waters

    International Nuclear Information System (INIS)

    Suarez Antola, R.

    2006-03-01

    In highly stratified estuarine waters, with significant sediment loads, it is fairly difficult to predict the T90, the time scale that characterizes the bacterial inactivation or death, using mathematical formulae, so that suitable experiments must be done using tracers to measure physical dilution and microbiological methods to measure bacterial disappearance or inactivation. The location and characteristics of a second sewage outfall for the city of Montevideo is being determined. In this framework, several experiments with tracers were done to measure the self-purifying capacity of the coastal waters at the selected site. Due to the difficulties in the design and interpretation of the measurements, special mathematical models were constructed and applied to help in obtaining a deeper understanding of the complex advection-dispersion-inactivation processes. In this report the construction and the solution of the equations of an analytical model that guided all the subsequent modelling activities is described. The tracer and the bacteria fields are obtained as products of a function of time and the horizontal coordinates by a series of decaying exponential functions of time weighted by functions of depth. The quotient between the bacteria concentration and the tracer concentration, that is commonly used to determine a global value of T90 , taking suitable average values after a long enough transient, is studied. A procedure that may be used to summarize the field of local inactivation times by a few parameters, determined by tracer experiments and microbiological measurements, is discussed. A half-empirical correlation formula between the T90 parameter and the main variables of the body of receiving waters is suggested from the results of tracer experiments and other sources of information. The advantages and limitations of the modelling approach used in this case are assessed and some possible improvements are briefly outlined

  8. Interpretations of Tracer Tests Performed in the Culebra Dolomite at the Waste Isolation Pilot Plant Site

    International Nuclear Information System (INIS)

    MEIGS, LUCY C.; BEAUHEIM, RICHARD L.; JONES, TOYA L.

    2000-01-01

    This report provides (1) an overview of all tracer testing conducted in the Culebra Dolomite Member of the Rustler Formation at the Waste Isolation Pilot Plant (WPP) site, (2) a detailed description of the important information about the 1995-96 tracer tests and the current interpretations of the data, and (3) a summary of the knowledge gained to date through tracer testing in the Culebra. Tracer tests have been used to identify transport processes occurring within the Culebra and quantify relevant parameters for use in performance assessment of the WIPP. The data, especially those from the tests performed in 1995-96, provide valuable insight into transport processes within the Culebra. Interpretations of the tracer tests in combination with geologic information, hydraulic-test information, and laboratory studies have resulted in a greatly improved conceptual model of transport processes within the Culebra. At locations where the transmissivity of the Culebra is low ( -6 m 2 /s), we conceptualize the Culebra as a single-porosity medium in which advection occurs largely through the primary porosity of the dolomite matrix. At locations where the transmissivity of the Culebra is high (> 4 x 10 -6 m 2 /s), we conceptualize the Culebra as a heterogeneous, layered, fractured medium in which advection occurs largely through fractures and solutes diffuse between fractures and matrix at multiple rates. The variations in diffusion rate can be attributed to both variations in fracture spacing (or the spacing of advective pathways) and matrix heterogeneity. Flow and transport appear to be concentrated in the lower Culebra. At all locations, diffusion is the dominant transport process in the portions of the matrix that tracer does not access by flow

  9. Quantification of methane and nitrous oxide emissions from various waste treatment facilities by tracer dilution method

    Science.gov (United States)

    Mønster, Jacob; Rella, Chris; Jacobson, Gloria; Kjeldsen, Peter; Scheutz, Charlotte

    2013-04-01

    Urban activities generate solid and liquid waste, and the handling and aftercare of the waste results in the emission of various compounds into the surrounding environment. Some of these compounds are emitted as gasses into the atmosphere, including methane and nitrous oxide. Methane and nitrous oxide are strong greenhouse gases and are considered to have 25 and 298 times the greenhouse gas potential of carbon dioxide on a hundred years term (Solomon et al. 2007). Global observations of both gasses have shown increasing concentrations that significantly contribute to the greenhouse gas effect. Methane and nitrous oxide are emitted from both natural and anthropogenic sources and inventories of source specific fugitive emissions from the anthropogenic sources of methane and nitrous oxide of are often estimated on the basis of modeling and mass balance. Though these methods are well-developed, actual measurements for quantification of the emissions is a very useful tool for verifying the modeling and mass balance as well as for validation initiatives done for lowering the emissions of methane and nitrous oxide. One approach to performing such measurements is the tracer dilution method (Galle et al. 2001, Scheutz et al. 2011), where the exact location of the source is located and a tracer gas is released at this source location at a known flow. The ratio of downwind concentrations of the tracer gas and the methane and nitrous oxide gives the emissions rates of the greenhouse gases. This tracer dilution method can be performed using both stationary and mobile measurements and in both cases, real-time measurements of both tracer and quantified gas are required, placing high demands on the analytical detection method. To perform the methane and nitrous oxide measurements, two robust instruments capable of real-time measurements were used, based on cavity ring-down spectroscopy and operating in the near-infrared spectral region. One instrument measured the methane and

  10. Modelling the transport and decay processes of microbial tracers in a macro-tidal estuary.

    Science.gov (United States)

    Abu-Bakar, Amyrhul; Ahmadian, Reza; Falconer, Roger A

    2017-10-15

    The Loughor Estuary is a macro-tidal coastal basin, located along the Bristol Channel, in the South West of the U.K. The maximum spring tidal range in the estuary is up to 7.5 m, near Burry Port Harbour. This estuarine region can experience severe coastal flooding during high spring tides, including extreme flooding of the intertidal saltmarshes at Llanrhidian, as well as the lower industrial and residential areas at Llanelli and Gowerton. The water quality of this estuarine basin needs to comply with the designated standards for safe recreational bathing and shellfish harvesting industries. The waterbody however, potentially receives overloading of bacterial inputs that enter the estuarine system from both point and diffuse sources. Therefore, a microbial tracer study was carried out to get a better understanding of the faecal bacteria sources and to enable a hydro-environmental model to be refined and calibrated for both advection and dispersion transport. A two-dimensional hydro-environmental model has been refined and extended to predict the highest water level covering the intertidal floodplains of the Loughor Estuary. The validated hydrodynamic model for both water levels and currents, was included with the injected mass of microbial tracer, i.e. MS2 coliphage from upstream of the estuary, and modelled as a non-conservative tracer over several tidal cycles through the system. The calibration and validation of the transport and decay of microbial tracer was undertaken, by comparing the model results and the measured data at two different sampling locations. The refined model developed as a part of this study, was used to acquire a better understanding of the water quality processes and the potential sources of bacterial pollution in the estuary. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Tracer signals of the intermediate layer of the Arabian Sea

    Science.gov (United States)

    Rhein, Monika; Stramma, Lothar; Plähn, Olaf

    In 1995, hydrographic and chlorofluorocarbon (CFCs, components F11, F12) measurements were carried out in the Gulf of Aden, in the Gulf of Oman, and in the Arabian Sea. In the Gulf of Oman, the F12 concentrations in the Persian Gulf outflow (PGW) at about 300m depth were significantly higher than in ambient surface water with saturations reaching 270%. These high values could not be caused by air-sea gas exchange. The outflow was probably contaminated with oil, and the lipophilic character of the CFCs could then lead to the observed supersaturations. The intermediate F12 maximum decreased rapidly further east and south. At the Strait of Bab el Mandeb in the Gulf of Aden, the Red Sea outflow (RSW) was saturated with F12 to about 65% at 400m depth, and decreased to 50% while descending to 800m depth. The low saturation is not surprising, because the outflow contains deep and intermediate water masses from the Red Sea which were isolated from the surface for some time. The tracer contributions to the Arabian Sea for Indian Central Water (ICW) and PGW are about equal, while below 500m depth the RSW contribution greatly exceeds ICW. Modeling the CFC budget of the Arabian Sea, the inflow of ICW north of 12°N is estimated to be 1-6 Sv, depending mainly on the strength of the flow of Red Sea Water into the Arabian Sea.

  12. Predictions of tracer transport in interwell tracer tests at the C-Hole complex. Yucca Mountain site characterization project report milestone 4077

    International Nuclear Information System (INIS)

    Reimus, P.W.

    1996-09-01

    This report presents predictions of tracer transport in interwell tracer tests that are to be conducted at the C-Hole complex at the Nevada Test Site on behalf of the Yucca Mountain Site Characterization Project. The predictions are used to make specific recommendations about the manner in which the tracer test should be conducted to best satisfy the needs of the Project. The objective of he tracer tests is to study flow and species transport under saturated conditions in the fractured tuffs near Yucca Mountain, Nevada, the site of a potential high-level nuclear waste repository. The potential repository will be located in the unsaturated zone within Yucca Mountain. The saturated zone beneath and around the mountain represents the final barrier to transport to the accessible environment that radionuclides will encounter if they breach the engineered barriers within the repository and the barriers to flow and transport provided by the unsaturated zone. Background information on the C-Holes is provided in Section 1.1, and the planned tracer testing program is discussed in Section 1.2

  13. Suitability of tracers; Eignung von Tracern

    Energy Technology Data Exchange (ETDEWEB)

    Klotz, D. [GSF - Forschungszentrum fuer Umwelt und Gesundheit GmbH, Neuherberg (Germany). Inst. fuer Hydrologie

    1999-02-01

    Hydrological tracer techniques are a means of making statements on the direction and speed of underground water. One of the simpler tasks is to find out whether there is hydrological communication between two given points. This requires a determination of the direction of flow, which places less exacting demands on the properties of the tracer than does the task of determining the flow velocity of underground water. Tracer methods can serve to infer from flow velocity the distance (flow) velocity, which is defined as the ratio between the distance between two points located in flow direction and the actual time it takes water to flow from one to the other. [Deutsch] Mit Hilfe der hydrologischen Markierungstechniken koennen Aussagen ueber die Richtung und die Geschwindigkeit von Bewegungen des unterirdischen Wassers gemacht werden. Der einfachere Fall liegt vor, wenn festgestellt werden soll, ob zwischen zwei Punkten eine hydrologische Verbindung besteht. Bei dieser Fliessrichtungsbestimmung sind die Forderungen an die Eigenschaften der einzusetzenden Tracer geringer als bei der Bestimmung der Geschwindigkeit des unterirdischen Wassers. Von den Geschwindigkeiten des unterirdischen Wassers ist die Abstands-(Fliess)geschwindigkeit, die definiert ist durch das Verhaeltnis aus dem Abstand und der wahren Fliesszeit zwischen zwei in Bewegungsrichtung gelegenen Punkten, durch Tracermethoden zu bestimmen. (orig.)

  14. Pipeline leak detection using volatile tracers

    International Nuclear Information System (INIS)

    Thompson, G.M.; Golding, R.D.

    1993-01-01

    A method of leak detection for underground storage tanks and pipelines adds volatile tracers to the products in the tanks and analyzes the surrounding shallow soil gases for tracer vapors. This method has several advantages: the success of the test is not limited by the size and structural design of the vessels, tanks can be tested at any fill level without taking the tank out of service, the location of a leak along a pipeline is clearly marked by the location of the tracer, and liquid leaks as small as 0.2 liters per hour (lph) can be detected. A limitation is: the backfill material must have some degree of air permeability in the zone above the water table. Several field tests document the success achieved using this method. A tracer leak detection system was installed at Homestead AFB after several other testing methods failed to locate a leak at a valve pit location along approximately 4 kilometers of fuel transfer piping. The leak was detected to the side of the valve pit at a depth of approximately 2.5 meters below the ground surface. Another installation of Edwards AFB involved the collection of 415 soil gas samples along approximately 3,050 meters of 15.25-centimeter fiberglass pipeline. Fourteen separate leaks were detected

  15. Determination of the self purification of streams using tracers

    International Nuclear Information System (INIS)

    Salviano, J.S.

    1982-04-01

    A methodology for the 'in situ' evaluation of the self purification of streams is discussed. It consists of the simultaneous injection of two tracers into the stream. One of the tracers is oxidized by biochemical processes. It can be either artificially supplied to the stream or a naturally present component can be used. This tracer is used for the determination of the self purification parameters. The other tracer is conservative and allows for the hydrodynamic effects. Tests have been carried out in two streams with quite different hydrodynamic and physicochemical conditions. In the first stream, with a flow-rate of about 0.9 m 3 /s, urea was used as the nonconservative tracer. In the other stream, which had a flow-rate of about 5 m 3 /s, only a radioactive tracer has been used, and the rate of biochemical oxidation has been determined from BOD measurements. Calculations have been implemented on a digital computer. In both cases it was found that the reoxygenation rate is more conveniently determined by empirical formulas. Results from both tests have been deemed realistic by comparison with similar experiments. (Author) [pt

  16. Use of 99mTc from a commercial 99Mo/9mTc generator as yield tracer for the determination of 99Tc at low levels

    DEFF Research Database (Denmark)

    Hou, Xiaolin; Jensen, Mikael; Nielsen, Sven Poul

    2007-01-01

    The concentrations of Tc-99 and impurity radionuclides in the Tc-99m tracer solution obtained from a commercial Mo-99/Tc-99m generator were measured by gamma spectrometry and liquid scintillation counting. Mo-99 and Ru-103 were found in the Tc-99m eluate. A simple separation using two extra alumina...... cartridges was investigated to purify the eluate to obtain a suitable Tc-99m tracer with low Tc-99 concentration. The activity ratio of Tc-99/Tc-99m in the prepared Tc-99m solution is lower than 15 x 10(-9), which is higher than the theoretical ratio of less than 10 x 10(-9). The possible reason is discussed....... The Tc-99 in the 20 kBq spiked Tc-99m tracer was found to be less than 0.3mBq, which is lower than the detection limit of the radiometric method used for environmental samples. The purified Tc-99m eluate is used as yield tracer for the determination of low levels of Tc-99 in environmental samples. (c...

  17. Tracer diffusion in a polymer gel: simulations of static and dynamic 3D networks using spherical boundary conditions

    International Nuclear Information System (INIS)

    Kamerlin, Natasha; Elvingson, Christer

    2016-01-01

    We have investigated an alternative to the standard periodic boundary conditions for simulating the diffusion of tracer particles in a polymer gel by performing Brownian dynamics simulations using spherical boundary conditions. The gel network is constructed by randomly distributing tetravalent cross-linking nodes and connecting nearest pairs. The final gel structure is characterised by the radial distribution functions, chain lengths and end-to-end distances, and the pore size distribution. We have looked at the diffusion of tracer particles with a wide range of sizes, diffusing in both static and dynamic networks of two different volume fractions. It is quantitatively shown that the dynamical effect of the network becomes more important in facilitating the diffusional transport for larger particle sizes, and that one obtains a finite diffusion also for particle sizes well above the maximum in the pore size distribution. (paper)

  18. Wirelessly powered micro-tracer enabled by miniaturized antenna and microfluidic channel

    International Nuclear Information System (INIS)

    Duan, G; Zhao, X; Seren, H R; Chen, C; Zhang, X

    2015-01-01

    A miniaturized antenna, 380μm by 380μm in size, was fabricated and integrated with a commercialized passive RFID chip to form a micro-tracer, whose size was 2mm by 1mm in total. The micro-tracer was wirelessly powered and interrogated by a single layer spiral reader antenna through near field coupling. To maximize the working distance, the resonant frequency of micro-tracer and reader antenna were matched at 840MHz. Due to the ultra small size of the tracer antenna, power transfer efficiency decreased dramatically as the distance between tracer antenna and reader antenna increased, thus the working distance of the microtracer was limited within 1mm. To achieve massive operation of the micro-tracer, a microfluidic platform was fabricated with in channel focusing and separation. Acrylic sheets were laser cut to define the channel and cover structure, then bonded together layer by layer with a glass substrate, on which reader antenna was integrated. Pump oil was used as the fluidic media carrying the micro-tracer flowing inside the microfluidic channel. The wireless power transfer and real-time communication was demonstrated with the micro-tracer flowing above the reader antenna, as the ID of the micro-tracer was retrieved and displayed on a computer screen. (paper)

  19. Tracer transport modeling with the Alliances platform in the presence of evapotranspiration

    Energy Technology Data Exchange (ETDEWEB)

    Constantin, A.; Diaconu, D.; Bucur, C. [Institute for Nuclear Research, Pitesti (Romania); Genty, A. [CEA Saclay, Gif-sur-Yvette (France)

    2013-11-15

    The knowledge and understanding of water flow and solute transport in the unsaturated zone is becoming increasingly important especially in mitigation of groundwater pollution. Fate of radionuclide in the geological environment is a topic to address in performance and safety assessment studies for nuclear waste disposal and may be modeled considering flow and transport in porous media. However, often, due to the heterogeneity and anisotropy of the real systems, the computer simulations may be difficult to render the real behavior. This paper addresses the simulation of a tracer transport in the unsaturated zone of the Saligny site, the potential location for the Romanian low and intermediate level waste (LILW) disposal. Computation was based on experimental data and was performed with the Alliances platform, a numerical tool developed by French organizations CEA, ANDRA and EDF. In order to obtain information regarding the solute migration in depth and the solute lateral dispersion, the dispersivity coefficients of iodine were investigated in order to match the experimental concentration determined on samples from different locations of the site. A close fit of the simulation over experimental data for the water saturation profile at a depth of 0.5 m in transient state was targeted by taking into account evapotranspiration in order to obtain a realistic estimation of the water infiltration in the porous media. Dispersivity coefficients obtained from the simulation of the tracer transport are in good order of magnitude for the unsaturated area and allow to have a good preview of the tracer plume. However, further investigations are recommended on new samples in order to validate the migration of the tracer plume as expected. (orig.)

  20. Quantitative Visualization of Dynamic Tracer Transportation in the Extracellular Space of Deep Brain Regions Using Tracer-Based Magnetic Resonance Imaging

    Science.gov (United States)

    Hou, Jin; Wang, Wei; Quan, Xianyue; Liang, Wen; Li, Zhiming; Han, Hongbin; Chen, Deji

    2017-01-01

    Background This study assessed an innovative tracer-based magnetic resonance imaging (MRI) system to visualize the dynamic transportation of tracers in regions of deep brain extracellular space (ECS) and to measure transportation ability and ECS structure. Material/Methods Gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) was the chosen tracer and was injected into the caudate nucleus and thalamus. Real-time dynamic transportation of Gd-DTPA in ECS was observed and the results were verified by laser scanning confocal microscopy. Using Transwell assay across the blood-brain barrier, a modified diffusion equation was further simplified. Effective diffusion coefficient D* and tortuosity λ were calculated. Immunohistochemical staining and Western blot analysis were used to investigate the extracellular matrix contributing to ECS structure. Results Tracers injected into the caudate nucleus were transported to the ipsilateral frontal and temporal cortices away from the injection points, while both of them injected into the thalamus were only distributed on site. Although the caudate nucleus was closely adjacent to the thalamus, tracer transportation between partitions was not observed. In addition, D* and the λ showed statistically significant differences between partitions. ECS was shown to be a physiologically partitioned system, and its division is characterized by the unique distribution territory and transportation ability of substances located in it. Versican and Tenascin R are possible contributors to the tortuosity of ECS. Conclusions Tracer-based MRI will improve our understanding of the brain microenvironment, improve the techniques for local delivery of drugs, and highlight brain tissue engineering fields in the future. PMID:28866708

  1. Quantitative Visualization of Dynamic Tracer Transportation in the Extracellular Space of Deep Brain Regions Using Tracer-Based Magnetic Resonance Imaging.

    Science.gov (United States)

    Hou, Jin; Wang, Wei; Quan, Xianyue; Liang, Wen; Li, Zhiming; Chen, Deji; Han, Hongbin

    2017-09-03

    BACKGROUND This study assessed an innovative tracer-based magnetic resonance imaging (MRI) system to visualize the dynamic transportation of tracers in regions of deep brain extracellular space (ECS) and to measure transportation ability and ECS structure. MATERIAL AND METHODS Gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA) was the chosen tracer and was injected into the caudate nucleus and thalamus. Real-time dynamic transportation of Gd-DTPA in ECS was observed and the results were verified by laser scanning confocal microscopy. Using Transwell assay across the blood-brain barrier, a modified diffusion equation was further simplified. Effective diffusion coefficient D* and tortuosity λ were calculated. Immunohistochemical staining and Western blot analysis were used to investigate the extracellular matrix contributing to ECS structure. RESULTS Tracers injected into the caudate nucleus were transported to the ipsilateral frontal and temporal cortices away from the injection points, while both of them injected into the thalamus were only distributed on site. Although the caudate nucleus was closely adjacent to the thalamus, tracer transportation between partitions was not observed. In addition, D* and the λ showed statistically significant differences between partitions. ECS was shown to be a physiologically partitioned system, and its division is characterized by the unique distribution territory and transportation ability of substances located in it. Versican and Tenascin R are possible contributors to the tortuosity of ECS. CONCLUSIONS Tracer-based MRI will improve our understanding of the brain microenvironment, improve the techniques for local delivery of drugs, and highlight brain tissue engineering fields in the future.

  2. Use of radioactive tracers in dynamic sedimentology

    International Nuclear Information System (INIS)

    Tola, Francois.

    1982-01-01

    In the first part, developments in the use of radioactive tracers in sedimentology are recalled together with the corresponding fields of application and the identities of the main users. The state-of-the-art in France is also discussed; The main characteristics of the method are then described and compared with those of more classical methods. The results that can be obtained with tracer methods are then outlined. The criteria employed to establish the granulometry characteristics of the tracer, the particular radioisotope to be used, and the masses and activities involved, are treated. A list is then given of the main isotopes available in France and their characteristics. The various different labelling techniques employed are studied together with their respective advantages and disadvantages. The special case of pelitic sediments is mentioned. The use of reduced model isotope generators, double labelling and applications to studies of the mud plug in the Gironde Estuary are also discussed. The methods and materials used for injecting and detecting tracers are described, emphasis being given to the economic factors associated with the use of radioactive tracers in sedimentology. The second part of the report contains two chapters: - studies of transport by driftage: presentation and analysis of results and the application of the Count Rate Balance method to obtain quantitative information on transport; - studies of in-suspension transport of fine sediments in the sea: the procedures adopted from the moment when the tracer is introduced up to the time when the results are analyzed and interpreted, enables the trajectories and mean velocities of the transported sediments to be determined together with their degree of dilution and their settling speeds and rates; it is also possible to investigate the evolution and horizontal dispersion of the sediments in this way. Results from recent experiments are presented in both parts of the report

  3. Using neural networks to describe tracer correlations

    Directory of Open Access Journals (Sweden)

    D. J. Lary

    2004-01-01

    Full Text Available Neural networks are ideally suited to describe the spatial and temporal dependence of tracer-tracer correlations. The neural network performs well even in regions where the correlations are less compact and normally a family of correlation curves would be required. For example, the CH4-N2O correlation can be well described using a neural network trained with the latitude, pressure, time of year, and methane volume mixing ratio (v.m.r.. In this study a neural network using Quickprop learning and one hidden layer with eight nodes was able to reproduce the CH4-N2O correlation with a correlation coefficient between simulated and training values of 0.9995. Such an accurate representation of tracer-tracer correlations allows more use to be made of long-term datasets to constrain chemical models. Such as the dataset from the Halogen Occultation Experiment (HALOE which has continuously observed CH4  (but not N2O from 1991 till the present. The neural network Fortran code used is available for download.

  4. Using radioactive tracer technique in municipal hygiene

    International Nuclear Information System (INIS)

    Yurasova, O.I.

    1974-01-01

    Work of the A. N. Syrsin Institute of General and Municiapl Hygiene using raidoactive tracers is reviewed. The studies include research on protein metabolism in the living organism following action of unfavorable factors of the environment; determination of the paths of introduction into the organism of substances with an alien composition; and study of the rate of resorption of subcutaneous papuli. Results are shown of radioactive-tracer studies on the mechanism of action of poisonous substances on the living organism and of migration of alien chemical compounds in the organism and in objects in the environment. It is concluded that the radioactive tracer method has wide application in municipal hygiene and sanitary microbiology. The absence of laborious operations, economy of time, precision of the experiments, and the possibility of obtaining additional information on the mechanism of action of poisonous substances on the organism and the low cost of such studies compared with other methods makes the radioactive tracer method economically attractive. The studies made show the various types of use of the method in municipal hygiene and sanitary microbiology

  5. Using radioactive tracer technique in municipal hygiene

    Energy Technology Data Exchange (ETDEWEB)

    Yurasova, O I [Institut Obshchej i Kommunal' noj Gigieny, Moscow (USSR)

    1974-01-01

    Work of the A. N. Syrsin Institute of General and Municiapl Hygiene using raidoactive tracers is reviewed. The studies include research on protein metabolism in the living organism following action of unfavorable factors of the environment; determination of the paths of introduction into the organism of substances with an alien composition; and study of the rate of resorption of subcutaneous papuli. Results are shown of radioactive-tracer studies on the mechanism of action of poisonous substances on the living organism and of migration of alien chemical compounds in the organism and in objects in the environment. It is concluded that the radioactive tracer method has wide application in municipal hygiene and sanitary microbiology. The absence of laborious operations, economy of time, precision of the experiments, and the possibility of obtaining additional information on the mechanism of action of poisonous substances on the organism and the low cost of such studies compared with other methods makes the radioactive tracer method economically attractive. The studies made show the various types of use of the method in municipal hygiene and sanitary microbiology.

  6. Methods of 15N tracer research in biological systems

    International Nuclear Information System (INIS)

    Hirschberg, K.; Faust, H.

    1985-01-01

    The application of the stable isotope 15 N is of increasing importance in different scientific disciplines, especially in medicine, agriculture, and the biosciences. The close correlation between the growing interest and improvements of analytical procedures resulted in remarkable advances in the 15 N tracer technique. On the basis of the latest results of 15 N tracer research in life sciences and agriculture methods of 15 N tracer research in biological systems are compiled. The 15 N methodology is considered under three headings: Chemical analysis with a description of methods of sample preparation (including different separation and isolation methods for N-containing substances of biological and agricultural origin) and special procedures converting ammonia to molecular nitrogen. Isotopic analysis with a review on the most important methods of isotopic analysis of nitrogen: mass spectrometry (including the GC-MS technique), emission spectrometry, NMR spectroscopy, and other analytical procedures. 15 N-tracer techniques with a consideration of the role of the isotope dilution analysis as well as different labelling techniques and the mathematical interpretation of tracer data (modelling, N turnover experiments). In these chapters also sources of errors in chemical and isotopic analysis, the accuracy of the different methods and its importance on tracer experiments are discussed. Procedures for micro scale 15 N analysis and aspects of 15 N analysis on the level of natural abundance are considered. Furthermore some remarks on isotope effects in 15 N tracer experiments are made. (author)

  7. Tracer kinetic modelling of tumour angiogenesis based on dynamic contrast-enhanced CT and MRI measurements

    Energy Technology Data Exchange (ETDEWEB)

    Brix, Gunnar [Federal Office for Radiation Protection, Department of Medical and Occupational Radiation Protection, Oberschleissheim (Germany); Bundesamt fuer Strahlenschutz (BfS), Abteilung fuer medizinischen und beruflichen Strahlenschutz, Oberschleissheim (Germany); Griebel, Juergen [Federal Office for Radiation Protection, Department of Medical and Occupational Radiation Protection, Oberschleissheim (Germany); Kiessling, Fabian [RWTH-Aachen University, Department of Experimental Molecular Imaging, Aachen (Germany); Wenz, Frederik [University Medical Center Mannheim, University of Heidelberg, Department of Radiation Oncology, Mannheim (Germany)

    2010-08-15

    Technical developments in both magnetic resonance imaging (MRI) and computed tomography (CT) have helped to reduce scan times and expedited the development of dynamic contrast-enhanced (DCE) imaging techniques. Since the temporal change of the image signal following the administration of a diffusible, extracellular contrast agent (CA) is related to the local blood supply and the extravasation of the CA into the interstitial space, DCE imaging can be used to assess tissue microvasculature and microcirculation. It is the aim of this review to summarize the biophysical and tracer kinetic principles underlying this emerging imaging technique offering great potential for non-invasive characterization of tumour angiogenesis. In the first part, the relevant contrast mechanisms are presented that form the basis to relate signal variations measured by serial CT and MRI to local tissue concentrations of the administered CA. In the second part, the concepts most widely used for tracer kinetic modelling of concentration-time courses derived from measured DCE image data sets are described in a consistent and unified manner to highlight their particular structure and assumptions as well as the relationships among them. Finally, the concepts presented are exemplified by the analysis of representative DCE data as well as discussed with respect to present and future applications in cancer diagnosis and therapy. Depending on the specific protocol used for the acquisition of DCE image data and the particular model applied for tracer kinetic analysis of the derived concentration-time courses, different aspects of tumour angiogenesis can be quantified in terms of well-defined physiological tissue parameters. DCE imaging offers promising prospects for improved tumour diagnosis, individualization of cancer treatment as well as the evaluation of novel therapeutic concepts in preclinical and early-stage clinical trials. (orig.)

  8. Multimodel analysis of anisotropic diffusive tracer-gas transport in a deep arid unsaturated zone

    Science.gov (United States)

    Green, Christopher T.; Walvoord, Michelle Ann; Andraski, Brian J.; Striegl, Robert G.; Stonestrom, David A.

    2015-01-01

    Gas transport in the unsaturated zone affects contaminant flux and remediation, interpretation of groundwater travel times from atmospheric tracers, and mass budgets of environmentally important gases. Although unsaturated zone transport of gases is commonly treated as dominated by diffusion, the characteristics of transport in deep layered sediments remain uncertain. In this study, we use a multimodel approach to analyze results of a gas-tracer (SF6) test to clarify characteristics of gas transport in deep unsaturated alluvium. Thirty-five separate models with distinct diffusivity structures were calibrated to the tracer-test data and were compared on the basis of Akaike Information Criteria estimates of posterior model probability. Models included analytical and numerical solutions. Analytical models provided estimates of bulk-scale apparent diffusivities at the scale of tens of meters. Numerical models provided information on local-scale diffusivities and feasible lithological features producing the observed tracer breakthrough curves. The combined approaches indicate significant anisotropy of bulk-scale diffusivity, likely associated with high-diffusivity layers. Both approaches indicated that diffusivities in some intervals were greater than expected from standard models relating porosity to diffusivity. High apparent diffusivities and anisotropic diffusivity structures were consistent with previous observations at the study site of rapid lateral transport and limited vertical spreading of gas-phase contaminants. Additional processes such as advective oscillations may be involved. These results indicate that gases in deep, layered unsaturated zone sediments can spread laterally more quickly, and produce higher peak concentrations, than predicted by homogeneous, isotropic diffusion models.

  9. Identification and characterization of conservative organic tracers for use as hydrologic tracers for the Yucca Mountain Site characterization study

    International Nuclear Information System (INIS)

    Dombrowski, T.; Stetzenbach, K.

    1993-01-01

    This report is in two parts one for the fluorinated benzoic acids and one for the fluorinated aliphatic acids. The assumptions made in the report regarding the amount of tracer that will be used, dilution of the tracer during the test and the length of exposure (if any) to individuals drinking the water were made by the authors. These assumptions must really come from the USGS hydrologists in charge of the c-well tracer testing program. Accurate estimates of dilution of the tracer during the test are also important because of solubility limitations of some of the tracers. Three of the difluorobenzoic acids have relatively low solubilities and may not be usable if the dilution estimates are large. The toxicologist that reviewed the document agreed with our conclusion that the fluorinated benzoic and toluic acids do not represent a health hazard if used under the conditions as outlined in the report. We are currently testing 15 of these compounds, and if even if three difluorobenzoic acids cannot be used because of solubility limitations we will still have 12 tracers. The toxicologist felt that the aliphatic fluorinated acids potentially present more of a health risk than the aromatic. This assessment was based on the fact of a known allergic response to halothane anesthetic. This risk, although minimal, is known and he felt that was enough reason to recommend against their use. The authors feel that the toxicologists interpretation of this risk was overly conservative, however, we will not go against his recommendation at this time for the following reasons. First, without the aliphatic compounds we still have 12 to 15 fluorinated aromatic acids which, should be enough for the c-well tests. Second, to get a permit to use aliphatic compounds would undoubtedly require a hearing which could be quite lengthy

  10. 3-D migration experiment - report 2: Instrumentation and tracers

    International Nuclear Information System (INIS)

    Abelin, H.; Birgersson, L.; Gidlund, J.

    1987-11-01

    This report is one of the four reports describing the Stripa 3D experiment where water and tracer flow has been monitored in a specially excavated drift in the Stripa mine. The experiment was performed in a specially excavated drift at the 360 m level in granite. The whole ceiling and upper part of the walls were covered with more than 350 individual plastic sheets where the water flow into the drift could be collected. 11 different tracers were injected at distances between 11 and 50 m from the ceiling of the drift. The flow rate and tracer monitoring was kept up for more than two years. The tracer breakthrough curves and flow rate distributions were used to study the flow paths, velocities, hydraulic conductivities, dispersivities and channeling effects in the rock. The report describes the instrumentation developed and used as well as the tracers that were tested and used in the experiment. (orig.)

  11. Radioisotope tracers in industrial flow studies

    International Nuclear Information System (INIS)

    Easey, J.F.

    1987-01-01

    The scope of radioisotope tracer work carried out by ANSTO has involved most sectors of Australian industry including iron and steel coal, chemical, petrochemical, natural gas, metallurgical, mineral, power generation, liquified air plant, as well as port authorities, water and sewerage instrumentalities, and environmental agencies. A major class of such studies concerns itself with flow and wear studies involving industrial equipment. Some examples are discussed which illustrate the utility of radioisotope tracer techniques in these applications

  12. Tracers Detect Aquifer Contamination

    National Research Council Canada - National Science Library

    Enfield, Carl

    1995-01-01

    The EPA's National Laboratory (NRMRL) at Ada, OK, along with the University of Florida and the University of Texas, have developed a tracer procedure to detect the amount of contamination in aquifer formations...

  13. Surface runoff and transport of sulfonamide antibiotics and tracers on manured grassland.

    Science.gov (United States)

    Burkhardt, Michael; Stamm, Christian; Waul, Christopher; Singer, Heinz; Müller, Stephan

    2005-01-01

    Despite their common use in animal production the environmental fate of the veterinary sulfonamide antibiotics after excretion is only poorly understood. We performed irrigation experiments to investigate the transport of these substances with surface runoff on grassland. Liquid manure from pigs treated with sulfadimidine was spiked with sulfadiazine, sulfathiazole, the herbicide atrazine (2-chloro-4-ethylamino-6-isopropylamino-1,3,5-triazine), and the conservative tracer bromide and spread onto eight plots. Four plots received the same amounts of the spiked substances in aqueous solution (controls). Apart from the application matrix we varied the time between application and irrigation. Manure increased the runoff volume up to six times compared with the controls. It seemed that manure enhanced the runoff by sealing the soil surface. On manured plots the relative antibiotic concentrations in runoff were higher than on the controls, reaching an average of 0.3% (sulfadiazine), 0.8% (sulfathiazole), and 1.4% (sulfadimidine) of the input concentrations after a 1-d contact time. The corresponding values on the controls were 0.16% for sulfadiazine and 0.08% for sulfathiazole. After 3 d, the maximum values on the manured plots were even higher, whereas they had fallen below the limit of quantification on the controls. As a consequence, the sulfonamide losses were 10 to 40 times larger on the manured plots. The relative mobility of the sulfonamides on the control plots followed the trend expected from their chromatographic separation but the opposite was found on the manured plots. Hence it is important to consider explicitly the physical and chemical effects of manure when assessing the environmental fate of sulfonamides.

  14. Convective influx/glymphatic system: tracers injected into the CSF enter and leave the brain along separate periarterial basement membrane pathways.

    Science.gov (United States)

    Albargothy, Nazira J; Johnston, David A; MacGregor-Sharp, Matthew; Weller, Roy O; Verma, Ajay; Hawkes, Cheryl A; Carare, Roxana O

    2018-05-12

    Tracers injected into CSF pass into the brain alongside arteries and out again. This has been recently termed the "glymphatic system" that proposes tracers enter the brain along periarterial "spaces" and leave the brain along the walls of veins. The object of the present study is to test the hypothesis that: (1) tracers from the CSF enter the cerebral cortex along pial-glial basement membranes as there are no perivascular "spaces" around cortical arteries, (2) tracers leave the brain along smooth muscle cell basement membranes that form the Intramural Peri-Arterial Drainage (IPAD) pathways for the elimination of interstitial fluid and solutes from the brain. 2 μL of 100 μM soluble, fluorescent fixable amyloid β (Aβ) were injected into the CSF of the cisterna magna of 6-10 and 24-30 month-old male mice and their brains were examined 5 and 30 min later. At 5 min, immunocytochemistry and confocal microscopy revealed Aβ on the outer aspects of cortical arteries colocalized with α-2 laminin in the pial-glial basement membranes. At 30 min, Aβ was colocalised with collagen IV in smooth muscle cell basement membranes in the walls of cortical arteries corresponding to the IPAD pathways. No evidence for drainage along the walls of veins was found. Measurements of the depth of penetration of tracer were taken from 11 regions of the brain. Maximum depths of penetration of tracer into the brain were achieved in the pons and caudoputamen. Conclusions drawn from the present study are that tracers injected into the CSF enter and leave the brain along separate periarterial basement membrane pathways. The exit route is along IPAD pathways in which Aβ accumulates in cerebral amyloid angiopathy (CAA) in Alzheimer's disease. Results from this study suggest that CSF may be a suitable route for delivery of therapies for neurological diseases, including CAA.

  15. Interpretations of Tracer Tests Performed in the Culebra Dolomite at the Waste Isolation Pilot Plant Site

    Energy Technology Data Exchange (ETDEWEB)

    MEIGS,LUCY C.; BEAUHEIM,RICHARD L.; JONES,TOYA L.

    2000-08-01

    This report provides (1) an overview of all tracer testing conducted in the Culebra Dolomite Member of the Rustler Formation at the Waste Isolation Pilot Plant (WPP) site, (2) a detailed description of the important information about the 1995-96 tracer tests and the current interpretations of the data, and (3) a summary of the knowledge gained to date through tracer testing in the Culebra. Tracer tests have been used to identify transport processes occurring within the Culebra and quantify relevant parameters for use in performance assessment of the WIPP. The data, especially those from the tests performed in 1995-96, provide valuable insight into transport processes within the Culebra. Interpretations of the tracer tests in combination with geologic information, hydraulic-test information, and laboratory studies have resulted in a greatly improved conceptual model of transport processes within the Culebra. At locations where the transmissivity of the Culebra is low (< 4 x 10{sup -6} m{sup 2}/s), we conceptualize the Culebra as a single-porosity medium in which advection occurs largely through the primary porosity of the dolomite matrix. At locations where the transmissivity of the Culebra is high (> 4 x 10{sup -6} m{sup 2}/s), we conceptualize the Culebra as a heterogeneous, layered, fractured medium in which advection occurs largely through fractures and solutes diffuse between fractures and matrix at multiple rates. The variations in diffusion rate can be attributed to both variations in fracture spacing (or the spacing of advective pathways) and matrix heterogeneity. Flow and transport appear to be concentrated in the lower Culebra. At all locations, diffusion is the dominant transport process in the portions of the matrix that tracer does not access by flow.

  16. Feasibility of perfluorocarbon tracers (PFTs) in atmospheric source-receptor experiments

    International Nuclear Information System (INIS)

    Dietz, R.N.; Senum, G.I.

    1984-03-01

    A brief description of the perfluorocarbon tracer (PFT) system, which includes the tracers and the release equipment, the air samplers and the analyzers, is presented along with details on the research needs to provide a viable system for MATEX-scenario experiments. The present family of 2 viable PFTs needs to be increased to 5 to 6. Given the present precision of the analysis system, a one year long tracer experiment consisting of 4 hour releases every 60 hours from 5 different sites would require nearly 150 metric tons of PFTs at a cost of $15,000,000. Shortcomings in the programmable sampler include the pump, the sampling sequence control flexibility, data storage and retrieval, and the lack of remote communication capability; sampler adsorbent studies are also needed. The analytical system, including the catalyst processing bed, the chromatography column resolution, and the linearity of the detector, is in need of significant improvement. A higher resolution analysis system could significantly reduce analysis time but, more importantly, reduce tracer requirements more than 10-fold, for a cost savings potential of more than $13,000,000. A model is presented to demonstrate the feasibility of tracer material balances. Assessment of earlier long-range tracer experiments indicates the need for possibly 400 ground sampling sites requiring $8 to $14 million worth of samplers for a one-year tracer experiment. As many as six aircraft would be needed to conduct airborne model validation and material balance studies for each tracer plume

  17. Inverse constraints for emission fluxes of atmospheric tracers estimated from concentration measurements and Lagrangian transport

    Science.gov (United States)

    Pisso, Ignacio; Patra, Prabir; Breivik, Knut

    2015-04-01

    Lagrangian transport models based on times series of Eulerian fields provide a computationally affordable way of achieving very high resolution for limited areas and time periods. This makes them especially suitable for the analysis of point-wise measurements of atmospheric tracers. We present an application illustrated with examples of greenhouse gases from anthropogenic emissions in urban areas and biogenic emissions in Japan and of pollutants in the Arctic. We asses the algorithmic complexity of the numerical implementation as well as the use of non-procedural techniques such as Object-Oriented programming. We discuss aspects related to the quantification of uncertainty from prior information in the presence of model error and limited number of observations. The case of non-linear constraints is explored using direct numerical optimisation methods.

  18. Altered Tracer Distribution and Clearance in the Extracellular Space of the Substantia Nigra in a Rodent Model of Parkinson's Disease

    Directory of Open Access Journals (Sweden)

    Yuan Fang

    2017-07-01

    Full Text Available The relationship between extracellular space (ECS diffusion parameters and brain drug clearance is not well-studied, especially in the context of Parkinson's disease (PD. Therefore, we used a rodent model of PD to explore the distribution and clearance of a magnetic resonance tracer. Forty male Sprague Dawley rats were randomized into four different groups: a PD group, a Madopar group (PD + Madopar treatment, a sham group, and a control group. All rats received an injection of the extracellular tracer gadolinium-diethylene triaminepentacetic acid (Gd-DTPA directly into the substantia nigra (SN. ECS diffusion parameters including the effective diffusion coefficient (D*, clearance coefficient (k', ratio of the maximum distribution volume of the tracer (Vd-max%, and half-life (t1/2 were measured. We found that all parameters were significantly increased in the PD group compared to the other three groups (D*: F = 5.774, p = 0.0025; k': F = 20.00, P < 0.0001; Vd-max%: F = 12.81, P < 0.0001; and t1/2: F = 23.35, P < 0.0001. In conclusion, the PD group exhibited a wider distribution and lower clearance of the tracer compared to the other groups. Moreover, k' was more sensitive than D* for monitoring morphological and functional changes in the ECS in a rodent model of PD.

  19. Root zone effects on tracer migration in arid zones

    International Nuclear Information System (INIS)

    Tyler, S.W.; Walker, G.R.

    1994-01-01

    The study of groundwater recharge and soil water movement in arid regions has received increased attention in the search for safe disposal sites for hazardous wastes. In passing through the upper 1 to 2 m of most soil profiles, tracers indicative of recharge such as Cl, 2 H, 18 O, Br, 3 H, and 56 Cl are subjected to a wide range of processes not encountered deeper in the profile. This transition zone, where water enters as precipitation and leaves as recharge, is often ignored when environmental tracers are used to estimate deep soil water flux and recharge, yet its effect may be profound. In this work, we reexamine the processes of root extraction and its effect on the velocity and distribution of tracers. Examples are presented for idealized conditions, which show clearly the relation between the root zone processes and the deep drainage or recharge. The results indicate that, when recharge is small and root zone processes are not accounted for, tracer techniques can significantly overestimate recharge until the tracer has moved well below the root zone. By incorporating simple models of root zone processes, a clearer understanding of tracer distributions and a more accurate estimate of recharge can then be made. 11 refs., 9 figs

  20. Tracer tests - possibilities and limitations. Experience from SKB fieldwork: 1977-2007

    Energy Technology Data Exchange (ETDEWEB)

    Loefgren, Martin; Crawford, James; Elert, Mark (Kemakta Konsult AB, Stockholm (SE))

    2007-09-15

    Tracer tests have played, and still play, a central role in investigations relating to the understanding of radionuclide retention processes in the field. At present there is a debate within the scientific community concerning how, and to what extent, tracer tests can be used to evaluate large-scale and long-term transport and retardation of radionuclides and other solutes of interest for Safety Assessment of repositories for spent nuclear fuel. In this report the SKB fieldwork on tracer tests performed at Swedish sites from 1977 to 2007 is described and discussed. Furthermore, the knowledge and process understanding evolved during the decades of radionuclide transport experiments and modelling within the SKB programme is summarised. One of the main objectives of this report is to discuss what data and knowledge can be extracted from different in situ tests in a robust fashion. Given the level of complexity associated with transport processes that may occur over the timescale of a tracer test, the utility of tracer tests is considered in the context of evidence-based interpretations of data which we characterise in the form of a sequence of questions of increasing complexity. The complexity of this sequence ranges from whether connection can be confirmed between injection and withdrawal points to whether quantitative data can be extrapolated from a tracer test to be subsequently used in Safety Assessment. The main findings of this report are that: Field scale tracer tests can confirm flow connectivity. Field scale tracer tests confirm the existence of retention. Field scale tracer tests alone can only broadly substantiate our process understanding. However, if performing extensive Site Characterisation and integrating the tracer test results with the full range of geoscientific information available, much support can be given to our process understanding. Field scale tracer tests can deliver the product of the material property group MPG and the F-factor, valid

  1. Hybrid tracers for sentinel node biopsy

    International Nuclear Information System (INIS)

    Van Den Berg, N. S.; Kleinjan, G. I.; Valdés-Olmos, R. A.; Buckle, T.; Van Leeuwen, F. I.; Klop, W. M.; Horenblas, S.; Van Der Poel, H. G.

    2014-01-01

    Conventional sentinel node (SN) mapping is performed by injection of a radiocolloid followed by lymphoscintigraphy to identify the number and location of the primary tumor draining lymph node(s), the so-called SN(s). Over the last decade research has focused on the introduction of new imaging agents that can further aid (surgical) SN identification. Different tracers for SN mapping, with varying sizes and isotopes have been reported, most of which have proven their value in a clinical setting. A major challenge lies in transferring this diagnostic information obtained at the nuclear medicine department to the operating theatre thereby providing the surgeon with (image) guidance. Conventionally, an intraoperative injection of vital blue dye or a fluorescence dye is given to allow intraoperative optical SN identification. However, for some indications, the radiotracer-based approach remains crucial. More recently, hybrid tracers, that contain both a radioactive and fluorescent label, were introduced to allow for direct integration of pre- and intraoperative guidance technologies. Their potential is especially high when they are used in combination with new surgical imaging modalities and navigation tools. Next to a description of the known tracers for SN mapping, this review discusses the application of hybrid tracers during SN biopsy and how the introduction of these new techniques can further aid in translation of nuclear medicine information into the operating theatre.

  2. Use of (3H) and (125I) tracers in steroid radioimmunoassays

    International Nuclear Information System (INIS)

    Jeffcoate, S.L.

    1975-01-01

    The comparative use of 3 H and 125 I tracers in steroid radioimmunoassays will be discussed around the following points: - 3 H. Advantages: they can be purchased commercially and have a long shelf-life. Disadvantages: they may have reduced affinity for antibodies due to ''isotope effects''; the counting of β-emitters is more expensive and difficult; 3 H tracers are not available for all steroids. - 125 I. Advantages: gamma-counting is cheaper, simpler and more precise; 125 I tracers may have higher affinity for antibodies than unlabelled steroids; 125 I can be used to label any steroid. Disadvantages: 125 I tracers have a limited shelf-life (n.b. six months for 125 I histamine tracers). The high affinity of some tracers will be a big disadvantage if the unlabelled steroid cannot compete effectively

  3. Systems approach to tracer data in groundwater hydrology

    International Nuclear Information System (INIS)

    Saxena, R.K.

    1977-01-01

    A brief review of current mathematical methods for the analysis of tracer data in groundwater hydrology has been given. The description of the hydrological cycle as a whole or in part, by a system (compartment) or sub-system under linear and stationary conditions is discussed. Basic concepts of transit time, residence time, their distributions in time and response characteristics of a system are outlined. From the knowledge of tracer input, output and systems response function for a generalised system, reservoir capacity and storage for given period can be estimated. Use of a time series model for environmental tracer data in discreet time scale aimed at the solution of hydrological problems e.g. mean transit time and reservoir capacity is also explored. It is concluded that the combination of tracer data with systems approach can go a long way in the study of some complex hydrological problems. (author)

  4. Development of positron tracer for in vivo estimation of brain MAO-B activity

    International Nuclear Information System (INIS)

    Inoue, Osamu; Tominaga, Toshiyoshi; Fukuda, Nobuo; Suzuki, Kazutoshi; Yamasaki, Toshio

    1984-01-01

    Both the specificity and the measurable range of enzyme activity of this method were found to be much dependent upon the enzymatic properties of substrate-tracer. The measurable range of brain enzyme activity was found to be from zero to the maximum value which was dependent upon two factors; the elimination rate of substratetracer from the brain (Ksub(el)) and the Vsub(max)/Ksub(m) value of substrate. The detectable range of changes in enzyme activity can be made wider by using another substrate as a tracer which has a lower Vsub(max)/Ksub(m) value or larger Ksub(el) value. The specificity can be also favorably designed by selection of substrate with various enzymatic or physico-chemical properties as a tracer. N, N-dimethyl phenylethylamine (DMPEA) was selected as a substrate-tracer for the estimation of brain MAO-B activity. Very high accumulation of radioactivity into mouse brain at 1 min after intravenous injection of 11 C-DMPEA, and a long-term retention of radioactivity in the brain were observed. 11 C-DMPEA seemed to be metabolized to 11 C-dimethylamine by brain MAO, and be trapped by the blood-brain barrier. When various dosage of 1-deprenyl (a specific MAO-B inhibitor) were pretreated, brain radioactivity at 1 hr after injection of 11 C-DMPEA significantly decreased in a dosage (1-deprenyl)-dependent way, while pretreatment with clorgyline (a specific MAO-A inhibitor) had no effect. This decrease in radioactivity might be due to the decrease of the production rate of labeled metabolite ( 11 C-dimethylamine) in the brain. The relationship between the radioactivity remaining at 1 hr after injection and MAO-B activity remaining in the brain was quite paralle. 11 C-DMPEA seems to be a specific radiotracer for the external detection of alterations in MAO-B activity in the brain with a fair sensitivity. (J.P.N.)

  5. Novel tracer for radiation treatment planning; Welche neuen PET-Tracer braucht die Strahlentherapie?

    Energy Technology Data Exchange (ETDEWEB)

    Schwarzenboeck, S.; Krause, B.J. [Rostock Univ. (Germany). Klinik fuer Nuklearmedizin; Herrmann, K.; Gaertner, F.; Souvatzoglou, M. [Technische Univ. Muenchen (Germany). Klinik fuer Nuklearmedizin; Klaesner, B. [Klinikum Bogenhausen, Muenchen (Germany). Inst. fuer Radiologie und Nuklearmedizin

    2011-07-15

    PET and PET/CT with innovative tracers gain increasing importance in diagnosis and therapy management, and radiation treatment planning in radio-oncology besides the widely established FDG. The introduction of [{sup 18}F]Fluorothymidine ([{sup 18}F]FLT) as marker of proliferation, [{sup 18}F]Fluoromisonidazole ([{sup 18}F]FMISO) and [{sup 18}F]Fluoroazomycin-Arabinoside ([{sup 18}F]FAZA) as tracer of hypoxia, [{sup 18}F]Fluoroethyltyrosine ([{sup 18}F]FET) and [{sup 11}C]Methionine for brain tumour imaging, [{sup 68}Ga]DOTATOC for somatostatin receptor imaging, [{sup 18}F]FDOPA for dopamine synthesis and radioactively labeled choline derivatives for imaging phospholipid metabolism have opened novel approaches to tumour imaging. Some of these tracers have already been implemented into radio-oncology: Amino acid PET and PET/CT have the potential to optimise radiation treatment planning of brain tumours through accurate delineation of tumour tissue from normal tissue, necrosis and edema. Hypoxia represents a major therapeutic problem in radiation therapy. Hypoxia imaging is very attractive as it may allow to increase the dose in hypoxic tumours potentially allowing for a better tumour control. Advances in hybrid imaging, i.e. the introduction of MR/PET, may also have an impact in radio-oncology through synergies related to the combination of molecular signals of PET and a high soft tissue contrast of MRI as well as functional MRI capabilities. (orig.)

  6. Application of separable parameter space techniques to multi-tracer PET compartment modeling

    International Nuclear Information System (INIS)

    Zhang, Jeff L; Michael Morey, A; Kadrmas, Dan J

    2016-01-01

    Multi-tracer positron emission tomography (PET) can image two or more tracers in a single scan, characterizing multiple aspects of biological functions to provide new insights into many diseases. The technique uses dynamic imaging, resulting in time-activity curves that contain contributions from each tracer present. The process of separating and recovering separate images and/or imaging measures for each tracer requires the application of kinetic constraints, which are most commonly applied by fitting parallel compartment models for all tracers. Such multi-tracer compartment modeling presents challenging nonlinear fits in multiple dimensions. This work extends separable parameter space kinetic modeling techniques, previously developed for fitting single-tracer compartment models, to fitting multi-tracer compartment models. The multi-tracer compartment model solution equations were reformulated to maximally separate the linear and nonlinear aspects of the fitting problem, and separable least-squares techniques were applied to effectively reduce the dimensionality of the nonlinear fit. The benefits of the approach are then explored through a number of illustrative examples, including characterization of separable parameter space multi-tracer objective functions and demonstration of exhaustive search fits which guarantee the true global minimum to within arbitrary search precision. Iterative gradient-descent algorithms using Levenberg–Marquardt were also tested, demonstrating improved fitting speed and robustness as compared to corresponding fits using conventional model formulations. The proposed technique overcomes many of the challenges in fitting simultaneous multi-tracer PET compartment models. (paper)

  7. Distinguishing between natural and aquaculture-derived sediment concentrations of heavy metals in the Broughton Archipelago, British Columbia

    International Nuclear Information System (INIS)

    Sutherland, T.F.; Petersen, S.A.; Levings, C.D.; Martin, A.J.

    2007-01-01

    Marine sediment samples were collected in the Broughton Archipelago, British Columbia, to assess the use of a geochemical normalization technique in the identification of a chemical tracer of aquaculture waste material. Zinc and copper were suggested as tracers of feed pellets, while copper was considered an indicator of anti-foulant agents used on netpen systems. The sediment samples were analyzed for carbon, nitrogen, organic matter, water, trace-element, and free sulfide concentrations, and sediment grain-size distribution. Sediment texture analysis revealed a wide range of substrate types from sand to silty loam categories. Strong relationships between sediment texture, sediment porosity, and organic content were observed across both near-field and far-field stations. Excess zinc and copper sediment concentrations, identified using a lithium-normalization technique, were restricted to near-field sampling stations (0 and 30 m from netpen systems). The relationships between these metal tracers and organic content and sulfur concentrations were explored to account for variations in sediment concentrations of zinc and copper

  8. USING PERFLUOROCARBON TRACERS FOR VERIFICATION OF CAP AND COVER SYSTEMS PERFORMANCE

    International Nuclear Information System (INIS)

    HEISER, J.; SULLIVAN, T.

    2001-01-01

    subsurface barriers (1,2). The technology uses perfluorocarbon tracers (PFTs) to determine flaws (e.g., holes or cracks) and high permeability areas in subsurface barriers. Gaseous tracers are injected on one side of the barrier and searched for on the opposite side of the barrier. The sampling grid, concentration, and time of arrival of the tracer(s) on the opposite side are used to determine the size and location of flaws and relative permeability of the barrier. In addition, there are multiple tracers available, which allows different tracers to be injected in different quadrants of the barrier. This yields additional information on transport phenomena of the barrier

  9. Green River air quality model development: meteorological and tracer data, July/August 1982 field study in Brush Valley, Colorado

    Energy Technology Data Exchange (ETDEWEB)

    Whiteman, C.D.; Lee, R.N.; Orgill, M.M.; Zak, B.D.

    1984-06-01

    Meteorological and atmospheric tracer studies were conducted during a 3-week period in July and August of 1982 in the Brush Creek Valley of northwestern Colorado. The objective of the field experiments was to obtain data to evaluate a model, called VALMET, developed at PNL to predict dispersion of air pollutants released from an elevated stack located within a deep mountain valley in the post-sunrise temperature inversion breakup period. Three tracer experiments were conducted in the valley during the 2-week period. In these experiments, sulfur hexafluoride (SF/sub 6/) was released from a height of approximately 100 m, beginning before sunrise and continuing until the nocturnal down-valley winds reversed several hours after sunrise. Dispersion of the sulfur hexafluoride after release was evaluated by measuring SF/sub 6/ concentrations in ambient air samples taken from sampling devices operated within the valley up to about 8 km down valley from the source. An instrumented research aircraft was also used to measure concentrations in and above the valley. Tracer samples were collected using a network of radio-controlled bag sampling stations, two manually operated gas chromatographs, a continuous SF/sub 6/ monitor, and a vertical SF/sub 6/ profiler. In addition, basic meteorological data were collected during the tracer experiments. Frequent profiles of vertical wind and temperature structure were obtained with tethered balloons operated at the release site and at a site 7.7 km down the valley from the release site. 10 references, 63 figures, 50 tables.

  10. Experimental design for estimating parameters of rate-limited mass transfer: Analysis of stream tracer studies

    Science.gov (United States)

    Wagner, Brian J.; Harvey, Judson W.

    1997-01-01

    Tracer experiments are valuable tools for analyzing the transport characteristics of streams and their interactions with shallow groundwater. The focus of this work is the design of tracer studies in high-gradient stream systems subject to advection, dispersion, groundwater inflow, and exchange between the active channel and zones in surface or subsurface water where flow is stagnant or slow moving. We present a methodology for (1) evaluating and comparing alternative stream tracer experiment designs and (2) identifying those combinations of stream transport properties that pose limitations to parameter estimation and therefore a challenge to tracer test design. The methodology uses the concept of global parameter uncertainty analysis, which couples solute transport simulation with parameter uncertainty analysis in a Monte Carlo framework. Two general conclusions resulted from this work. First, the solute injection and sampling strategy has an important effect on the reliability of transport parameter estimates. We found that constant injection with sampling through concentration rise, plateau, and fall provided considerably more reliable parameter estimates than a pulse injection across the spectrum of transport scenarios likely encountered in high-gradient streams. Second, for a given tracer test design, the uncertainties in mass transfer and storage-zone parameter estimates are strongly dependent on the experimental Damkohler number, DaI, which is a dimensionless combination of the rates of exchange between the stream and storage zones, the stream-water velocity, and the stream reach length of the experiment. Parameter uncertainties are lowest at DaI values on the order of 1.0. When DaI values are much less than 1.0 (owing to high velocity, long exchange timescale, and/or short reach length), parameter uncertainties are high because only a small amount of tracer interacts with storage zones in the reach. For the opposite conditions (DaI ≫ 1.0), solute

  11. Identification and characterization of conservative organic tracers for use as hydrologic tracers for the Yucca Mountain site characterization study. Final report

    International Nuclear Information System (INIS)

    Stetzenbach, K.; Farnham, I.

    1996-01-01

    Extensive tracer testing is expected to take place at the C-well complex in the Nevada Test Site as part of the Yucca Mountain Site Characterization Project. The C-well complex consists of one pumping well, C3, and two injection wells, C1 and C2 into which tracer will be introduced. The goal of this research was to provide USGS with numerous tracers to completed these tests. Several classes of fluorinated organic acids have been evaluated. These include numerous isomers of fluorinated benzoic acids, cinnamic acids, and salicylic acids. Also several derivatives of 2-hydroxy nicotinic acid (pyridone) have been tested. The stability of these compounds was determined using batch and column tests. Ames testing (mutagenicity/carcinogenicity) was conducted on the fluorinated benzoic acids and a literature review of toxicity of the fluorobenzoates and three perfluoro aliphatic acids was prepared. Solubilities were measured and method development work was performed to optimize the detection of these compounds. A Quality Assurance (QA) Program was developed under existing DOE and USGS guidelines. The program includes QA procedures and technical standard operating procedures. A tracer test, using sodium iodide, was performed at the C-well complex. HRC chemists performed analyses on site, to provide real time data for the USGS hydrologists and in the laboratories at UNLV. Over 2,500 analyses were performed. This report provides the results of the laboratory experiments and literature reviews used to evaluate the potential tracers and reports on the results of the iodide C-well tracer test

  12. Identification and characterization of conservative organic tracers for use as hydrologic tracers for the Yucca Mountain site characterization study. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Stetzenbach, K.; Farnham, I.

    1996-06-01

    Extensive tracer testing is expected to take place at the C-well complex in the Nevada Test Site as part of the Yucca Mountain Site Characterization Project. The C-well complex consists of one pumping well, C3, and two injection wells, C1 and C2 into which tracer will be introduced. The goal of this research was to provide USGS with numerous tracers to completed these tests. Several classes of fluorinated organic acids have been evaluated. These include numerous isomers of fluorinated benzoic acids, cinnamic acids, and salicylic acids. Also several derivatives of 2-hydroxy nicotinic acid (pyridone) have been tested. The stability of these compounds was determined using batch and column tests. Ames testing (mutagenicity/carcinogenicity) was conducted on the fluorinated benzoic acids and a literature review of toxicity of the fluorobenzoates and three perfluoro aliphatic acids was prepared. Solubilities were measured and method development work was performed to optimize the detection of these compounds. A Quality Assurance (QA) Program was developed under existing DOE and USGS guidelines. The program includes QA procedures and technical standard operating procedures. A tracer test, using sodium iodide, was performed at the C-well complex. HRC chemists performed analyses on site, to provide real time data for the USGS hydrologists and in the laboratories at UNLV. Over 2,500 analyses were performed. This report provides the results of the laboratory experiments and literature reviews used to evaluate the potential tracers and reports on the results of the iodide C-well tracer test.

  13. Tritium and deuterium as water tracers in hydrologic systems. Completion report

    International Nuclear Information System (INIS)

    Stewart, G.L.; Stetson, J.R.

    1975-05-01

    A study was conducted to evaluate the suitability of deuterium and tritium as tracers to depict water and pollutant movement in porous media. This involved studying the interaction of these tracers with soil materials and evaluating this interaction in terms of retardation in tracer flow velocity, compared to bulk water flow. Previous work had suggested that tritium and deuterium interact with soils and are removed from tracer solution during flow. The data presented clearly show that a tracing front becomes diluted in tracer during infiltration into oven-dried soil. There appears to be very little difference between the degree of tritium and deuterium interaction. The source of interaction is demonstrated to be primarily hydroxyl associated with the clay minerals. These exchange sites are destroyed by heating soil to 70C which eliminates tracer loss during infiltration

  14. Impact of small-scale saline tracer heterogeneity on electrical resistivity monitoring in fully and partially saturated porous media: Insights from geoelectrical milli-fluidic experiments

    Science.gov (United States)

    Jougnot, Damien; Jiménez-Martínez, Joaquín; Legendre, Raphaël; Le Borgne, Tanguy; Méheust, Yves; Linde, Niklas

    2018-03-01

    Time-lapse electrical resistivity tomography (ERT) is a geophysical method widely used to remotely monitor the migration of electrically-conductive tracers and contaminant plumes in the subsurface. Interpretations of time-lapse ERT inversion results are generally based on the assumption of a homogeneous solute concentration below the resolution limits of the tomogram depicting inferred electrical conductivity variations. We suggest that ignoring small-scale solute concentration variability (i.e., at the sub-resolution scale) is a major reason for the often-observed apparent loss of solute mass in ERT tracer studies. To demonstrate this, we developed a geoelectrical milli-fluidic setup where the bulk electric conductivity of a 2D analogous porous medium, consisting of cylindrical grains positioned randomly inside a Hele-Shaw cell, is monitored continuously in time while saline tracer tests are performed through the medium under fully and partially saturated conditions. High resolution images of the porous medium are recorded with a camera at regular time intervals, and provide both the spatial distribution of the fluid phases (aqueous solution and air), and the saline solute concentration field (where the solute consists of a mixture of salt and fluorescein, the latter being used as a proxy for the salt concentration). Effective bulk electrical conductivities computed numerically from the measured solute concentration field and the spatial distributions of fluid phases agree well with the measured bulk conductivities. We find that the effective bulk electrical conductivity is highly influenced by the connectivity of high electrical conductivity regions. The spatial distribution of air, saline tracer fingering, and mixing phenomena drive temporal changes in the effective bulk electrical conductivity by creating preferential paths or barriers for electrical current at the pore-scale. The resulting heterogeneities in the solute concentrations lead to strong anisotropy

  15. Preclinical in vitro and in vivo evaluation of [11C]SNAP-7941 – the first PET tracer for the melanin concentrating hormone receptor 1

    International Nuclear Information System (INIS)

    Philippe, Cécile; Nics, Lukas; Zeilinger, Markus; Kuntner, Claudia; Wanek, Thomas; Mairinger, Severin; Shanab, Karem; Spreitzer, Helmut; Viernstein, Helmut; Wadsak, Wolfgang; Mitterhauser, Markus

    2013-01-01

    Introduction: Due to its involvement in a variety of pathologies (obesity, diabetes, gut inflammation and depression), the melanin concentrating hormone receptor 1 (MCHR1) is a new target for the treatment of these lifestyle diseases. We previously presented the radiosynthesis of [ 11 C]SNAP-7941, the first potential PET tracer for the MCHR1. Methods: We herein present its in vitro and in vivo evaluation, including binding affinity, plasma stability, stability against liver mircrosomes and carboxylesterase, lipohilicity, biodistribution, in vivo metabolism and small-animal PET. Results: [ 11 C]SNAP-7941 evinced high stability against liver microsomes, carboxylesterase and in human plasma. The first small-animal PET experiments revealed a 5 fold increased brain uptake after Pgp/BCRP inhibition. Therefore, it can be assumed that [ 11 C]SNAP-7941 is a Pgp/BCRP substrate. No metabolites were found in brain. Conclusion: On the basis of these experiments with healthy rats, the suitability of [ 11 C]SNAP-7941 for the visualisation of central and peripheral MCHR1 remains speculative

  16. Analysis of some laboratory tracer runs in natural fissures

    International Nuclear Information System (INIS)

    Moreno, L.; Neretnieks, I.

    1984-01-01

    Tracer tests in natural fissures performed in the laboratory are analysed by means of fitting two different models. In the experiments, sorbing and non-sorbing tracers were injected into a natural fissure running parallel to the axis of a drill core. The models take into account advection, diffusion into the rock matrix, sorption onto the rock surface and dispersion. For the last mechanism, one of the models considers hydrodynamic dispersion while the other model assumes channeling dispersion. The models take into account time delays in the inlet and outlet channels. The dispersion characteristics and water residence time were determined from the experiments with non-sorbing tracers. Surface and volume sorption coefficients and data on diffusion into the rock matrix were determined for the sorbing tracers. The results are compared with values independently determined in the laboratory. Good agreement was obtained using either model. When these models are used for prediction of tracer transport over larger distances, the results will depend on the model. The model with channeling dispersion will show a greater dispersion than the model with hydrodynamic dispersion. (author)

  17. Characterization and modeling of natural tracers' transfers through the argillites of Tournemire (France)

    International Nuclear Information System (INIS)

    Patriarche, D.

    2001-01-01

    The French Institute for Protection and Nuclear Safety (IPSN) is investigating the argillaceous formation of Tournemire (France) as a methodological underground laboratory for conducting research on the feasibility of deep geological repositories for radioactive waste in argilites. Because of the very low water content and hydraulic conductivity of the argilites, the migration through this media should be very low. The fluid flow regime and transport have been studied using natural tracers from the interstitial water. The deuterium and chloride of interstitial water have been chosen for their conservative behavior. After the development of a protocol for the chloride extraction from the water, and tests on the vacuum distillation method for the water extraction from the rock, systematic data acquisition has been performed on the argillaceous sequence of the massif and near the fracture areas. Both chloride and deuterium profiles suggest that transfers are mainly diffusive at the massif scale. But the profiles show an enrichment in delta D and delta 18 O of the interstitial solution in the area of one meter adjacent to a fracture compared to pore water of samples located at further distance. Therefore, these observations are suggesting that a second process could generate specific transfers, at the vicinity of faults. The hypothesis of the molecular diffusion as a dominant process for transport was successfully tested using a transport model, over periods of several tenth of millions years, taking into account geodynamical features of the region (such as tectonic and induced faults), and assuming that some variations of the tracer concentrations at the system boundaries occurred during the major climate-change periods. Even if tracers' transfers are mainly diffusive at the massif scale, they are or should have been affected by a second process causing heterogeneity of concentrations at the vicinity of faults. This process involves either, intrusion of salted

  18. 18O isotopic tracer studies of silicon oxidation in dry oxygen

    International Nuclear Information System (INIS)

    Han, C.J.

    1986-01-01

    Oxidation of silicon in dry oxygen has been an important process in the integrated circuit industry for making gate insulators on metal-oxide-semiconductory (MOS) devices. This work examines this process using isotopic tracers of oxygen to determine the transport mechanisms of oxygen through silicon dioxide. Oxides were grown sequentially using mass-16 and mass-18 oxygen gas sources to label the oxygen molecules from each step. The resulting oxides are analyzed using secondary ion mass spectrometry (SIMS). The results of these analyses suggest two oxidant species are present during the oxidation, each diffuses and oxidizes separately during the process. A model from this finding using a sum of two linear-parabolic growth rates, each representing the growth rate from one of the oxidants, describes the reported oxidation kinetics in the literature closely. A fit of this relationship reveals excellent fits to the data for oxide thicknesses ranging from 30 A to 1 μm and for temperatures ranging from 800 to 1200 0 C. The mass-18 oxygen tracers also enable a direct observation of the oxygen solubility in the silicon dioxide during a dry oxidation process. The SIMS profiles establish a maximum solubility for interstitial oxygen at 1000 0 C at 2 x 10 20 cm -3 . Furthermore, the mass-18 oxygen profiles show negligible network diffusion during an 1000 0 C oxidation

  19. Artificial sweeteners as potential tracers of municipal landfill leachate

    International Nuclear Information System (INIS)

    Roy, James W.; Van Stempvoort, Dale R.; Bickerton, Greg

    2014-01-01

    Artificial sweeteners are gaining acceptance as tracers of human wastewater in the environment. The 3 artificial sweeteners analyzed in this study were detected in leachate or leachate-impacted groundwater at levels comparable to those of untreated wastewater at 14 of 15 municipal landfill sites tested, including several closed for >50 years. Saccharin was the dominant sweetener in old (pre-1990) landfills, while newer landfills were dominated by saccharin and acesulfame (introduced 2 decades ago; dominant in wastewater). Cyclamate was also detected, but less frequently. A case study at one site illustrates the use of artificial sweeteners to identify a landfill-impacted groundwater plume discharging to a stream. The study results suggest that artificial sweeteners can be useful tracers for current and legacy landfill contamination, with relative abundances of the sweeteners potentially providing diagnostic ability to distinguish different landfills or landfill cells, including crude age-dating, and to distinguish landfill and wastewater sources. -- Highlights: • Artificial sweeteners detected at 14 of 15 municipal landfill sites. • Concentrations comparable to wastewater even at sites closed for >50 yr. • Saccharin elevated at all sites; potentially diagnostic of landfill impacts. • Potential for age-dating recent (past 2 decades) waste with acesulfame. -- Artificial sweeteners may be useful for tracing landfill leachate contamination and distinguishing it from wastewater impacts

  20. Study of transport in unsaturated sands using radioactive tracers

    International Nuclear Information System (INIS)

    Merritt, W.F.; Pickens, J.F.; Allison, G.B.

    1979-01-01

    A laboratory experiment was conducted to investigate the mixing that occurs as a series of labelled pulses of water are transported by gravity drainage down through a sand filled column having a water table imposed at the bottom. It also demonstrated the utility of gamma-ray emitting radioactive tracers in studying transport in unsaturated or saturated porous media. The motivation for pursuing this topic was developed from observing that the content of oxygen-18, deuterium and tritium in rainwater shows marked temporal variations whereas their concentrations below the water table in shallow ground water flow systems are generally found to show much less variation. (auth)

  1. The fluorescent tracer experiment on Holiday Beach near Mugu Canyon, Southern California

    Science.gov (United States)

    Kinsman, Nicole; Xu, J. P.

    2012-01-01

    After revisiting sand tracer techniques originally developed in the 1960s, a range of fluorescent coating formulations were tested in the laboratory. Explicit steps are presented for the preparation of the formulation evaluated to have superior attributes, a thermoplastic pigment/dye in a colloidal mixture with a vinyl chloride/vinyl acetate copolymer. In September 2010, 0.59 cubic meters of fluorescent tracer material was injected into the littoral zone about 4 kilometers upcoast of Mugu submarine canyon in California. The movement of tracer was monitored in three dimensions over the course of 4 days using manual and automated techniques. Detailed observations of the tracer's behavior in the coastal zone indicate that this tracer successfully mimicked the native beach sand and similar methods could be used to validate models of tracer movement in this type of environment. Recommendations including how to time successful tracer studies and how to scale the field of view of automated camera systems are presented along with the advantages and disadvantages of the described tracer methodology.

  2. Enhanced Oil Recovery: Aqueous Flow Tracer Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Joseph Rovani; John Schabron

    2009-02-01

    A low detection limit analytical method was developed to measure a suite of benzoic acid and fluorinated benzoic acid compounds intended for use as tracers for enhanced oil recovery operations. Although the new high performance liquid chromatography separation successfully measured the tracers in an aqueous matrix at low part per billion levels, the low detection limits could not be achieved in oil field water due to interference problems with the hydrocarbon-saturated water using the system's UV detector. Commercial instrument vendors were contacted in an effort to determine if mass spectrometry could be used as an alternate detection technique. The results of their work demonstrate that low part per billion analysis of the tracer compounds in oil field water could be achieved using ultra performance liquid chromatography mass spectrometry.

  3. Measurements of HFC-134a and HCFC-22 in groundwater and unsaturated-zone air: implications for HFCs and HCFCs as dating tracers

    Science.gov (United States)

    Haase, Karl B.; Busenberg, Eurybiades; Plummer, Niel; Casile, Gerolamo; Sanford, Ward E.

    2014-01-01

    A new analytical method using gas chromatography with an atomic emission detector (GC–AED) was developed for measurement of ambient concentrations of hydrochlorofluorocarbons (HCFCs) and hydrofluorocarbons (HFCs) in soil, air, and groundwater, with the goal of determining their utility as groundwater age tracers. The analytical detection limits of HCFC-22 (difluorochloromethane, CHClF2) and HFC-134a (1,2,2,2-tetrafluoroethane, C2H2F4) in 1 L groundwater samples are 4.3 × 10− 1 and 2.1 × 10− 1 pmol kg− 1, respectively, corresponding to equilibrium gas-phase mixing ratios of approximately 5–6 parts per trillion by volume (pptv). Under optimal conditions, post-1960 (HCFC-22) and post-1995 (HFC-134a) recharge could be identified using these tracers in stable, unmixed groundwater samples. Ambient concentrations of HCFC-22 and HFC-134a were measured in 50 groundwater samples from 27 locations in northern and western parts of Virginia, Tennessee, and North Carolina (USA), and 3 unsaturated-zone profiles were collected in northern Virginia. Mixing ratios of both HCFC-22 and HFC-134a decrease with depth in unsaturated-zone gas profiles with an accompanying increase in CO2 and loss of O2. Apparently, ambient concentrations of HCFC-22 and HFC-134a are readily consumed by methanotrophic bacteria under aerobic conditions in the unsaturated zone. The results of this study indicate that soils are a sink for these two greenhouse gases. These observations contradict the previously reported results from microcosm experiments that found that degradation was limited above-ambient HFC-134a. The groundwater HFC and HCFC concentrations were compared with concentrations of chlorofluorocarbons (CFCs, CFC-11, CFC-12, CFC-113) and sulfur hexafluoride (SF6). Nearly all samples had measured HCFC-22 or HFC-134a that were below concentrations predicted by the CFCs and SF6, with many samples showing a complete loss of HCFC-22 and HFC-134a. This study indicates that HCFC-22 and HFC-134

  4. Dynamics and mechanics of bed-load tracer particles

    Directory of Open Access Journals (Sweden)

    C. B. Phillips

    2014-12-01

    Full Text Available Understanding the mechanics of bed load at the flood scale is necessary to link hydrology to landscape evolution. Here we report on observations of the transport of coarse sediment tracer particles in a cobble-bedded alluvial river and a step-pool bedrock tributary, at the individual flood and multi-annual timescales. Tracer particle data for each survey are composed of measured displacement lengths for individual particles, and the number of tagged particles mobilized. For single floods we find that measured tracer particle displacement lengths are exponentially distributed; the number of mobile particles increases linearly with peak flood Shields stress, indicating partial bed load transport for all observed floods; and modal displacement distances scale linearly with excess shear velocity. These findings provide quantitative field support for a recently proposed modeling framework based on momentum conservation at the grain scale. Tracer displacement is weakly negatively correlated with particle size at the individual flood scale; however cumulative travel distance begins to show a stronger inverse relation to grain size when measured over many transport events. The observed spatial sorting of tracers approaches that of the river bed, and is consistent with size-selective deposition models and laboratory experiments. Tracer displacement data for the bedrock and alluvial channels collapse onto a single curve – despite more than an order of magnitude difference in channel slope – when variations of critical Shields stress and flow resistance between the two are accounted for. Results show how bed load dynamics may be predicted from a record of river stage, providing a direct link between climate and sediment transport.

  5. Methods for conduct of atmospheric tracer studies at ANSTO

    Energy Technology Data Exchange (ETDEWEB)

    Clark, G H; Stone, D J.M.; Pascoe, J H [Australian Nuclear Science and Technology Organisation (ANSTO), Lucas Heights, NSW (Australia). Environment Division

    2000-07-01

    A perfluorocarbon atmospheric tracer system has been developed to investigate atmospheric dispersion processes in the region surrounding the Lucas Heights Science and Technology Centre. This report discusses the tracer release, sampling and analysis methods.

  6. Effect of certain variables on the tumor and tissue distribution of tracers. Salicylates and vasoactive drugs

    International Nuclear Information System (INIS)

    Halpern, S.E.; Hagan, P.; Stern, P.; Gordon, R.; Dabbs, J.

    1981-01-01

    Attempts were made to increase the viable tumor concentration of 54Mn and 67Ga in a rat hepatoma model by administering rat angiotensin, tolazoline, and salicylates. Salicylates increased the tumor concentrations of 54Mn and improved 65Mn viable tumor/background ratios. 67Ga was not affected by the salicylates. The salicylate effect appeared to be mediated by intracellular mechanisms rather than alterations in plasma protein binding. Rat angiotensin slightly increased the concentrations of 67Ga in the tumors but not enough to suggest that it would be useful clinically. Tolazoline did not increase tumor uptake of the tracers

  7. A new method for measuring aerosol nebulizers output using radioactive tracers

    International Nuclear Information System (INIS)

    Gatnash, A.A.; Connolly, C.K.; Chandler, S.T.

    1998-01-01

    Reproducibility and comparability of bronchial challenge tests depends critically on accurate assessment of nebulizers output. Evaporation during nebulization means that simple weighing is inaccurate, overestimating the delivered dose of active ingredient. We wanted to quantify this effect in the context of intermittent nebulization, using a dosimeter as used in bronchial provocation tests. Output of three types of nebulizers, from the MEFAR dosimeter, was measured by radioactive tracer, using a standard solution of technetium-99m-pertechnetate (1.5 kBq x mL -1 ) in 4 mL of normal saline. The aerosol was impacted by suction onto a micro filter, and the radioactivity measured. Nebulizers were weighed before and after nebulization. Ratio of nebulized volume calculated from the radioactivity on the filter, to the total volume loss by weight, was expressed as nebulized ratio. The effect on output of two concentrations of methacholine, two tracers of different weights, and change in temperature, were assessed. Nebulized ratio varied between 44.1-71.6%. Results were more consistent within the same type of nebulizer than between different makes. Neither changes in molar concentration nor molecular weight affected nebulizer output or nebulized ratio. Mean nebulized ratio was 58.5%, showing that calibration by weighing, overestimates the delivered dose by a factor of approximately two. Measuring radioactivity eluted from a micro filter, onto which nebulized output had been impacted proved to be a satisfactory method of calibration. (au)

  8. Boundary integral method application in the transportation modeling of radioactive tracers in porous ways; Aplicacao do metodo da integral de contorno na modelagem do transporte de tracadores radioativos em meios porosos

    Energy Technology Data Exchange (ETDEWEB)

    Ferroni, Jose Geraldo

    1996-03-01

    This work describes a method for estimating the effluent concentrations of radioactive tracers in production wells, considering well to well injection tests and piston-like displacements of fluids in the reservoir. The model for tracer transportation takes into account effects of convection and hydrodynamic dispersion. (author)

  9. Maximum permissible concentration of radon {sup 222}Rn in air; La concentration maximale admissible du radon 222 dans l'air

    Energy Technology Data Exchange (ETDEWEB)

    Hamard, J; Beau, P G; Ergas, A [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires, departement de la protection sanitaire, service d' hygiene atomique

    1968-09-01

    In order to verify the validity of the values proposed for the maximum permissible concentration of {sup 222}Rn in air, one can either approach the problem: - by epidemiological studies tending to determine the relation dose-effect both quantitatively and qualitatively; - or by choosing a lung model and clearance constants allowing a more accurate determination of the delivered dose and the localisation of the more severely irradiated portions of the bronchial tree. The radon MPC have been calculated using the model and the respiration constants set up by the I.C.R.P. Task Group on Lung dynamics. Two cases have been considered, i.e. when the radon daughter products behave as soluble materials and as insoluble ones. The values which have been found have been compared with those given up to now by several national and international bodies. (authors) [French] Deux voies d'approche peuvent etre empruntees pour verifier la validite des valeurs proposees pour la concentration maximale admissible du radon 222 dans l'air: - etudes epidemiologiques tendant a preciser qualitativement et quantitativement la relation dose-effet; - choix d'un modele pulmonaire et de constantes d'epuration permettant une determination plus precise de la dose delivree et la localisation des segments de l'arbre pulmonaire les plus irradies. Les auteurs ont utilise pour le calcul de la CMA du radon le modele et les constantes respiratoires proposees par le Task Group on Lungs dynamics de la C.I.P.R. On a pris en consideration le cas ou les descendants du radon se comportent comme des substances solubles et celui ou ils se comportent comme des substances insolubles. Les valeurs trouvees sont comparees a celles proposees jusqu'alors par divers organismes nationaux et internationaux. (auteurs)

  10. The European tracer experiment ETEX: a real-time long range atmospheric dispersion model exercise in different weather conditions

    International Nuclear Information System (INIS)

    Graziani, G.; )

    1998-01-01

    Two long-range tracer experiments were conducted. An inert, non-depositing tracer was being released at Rennes in France for 12 hours. The 168 sampling ground stations were run by the National Meteorological Services. Twenty-four institutions took part in the real-time forecasting of the cloud evolution using 28 long-range dispersion models. The horizontal projection of the cloud evolution over Europe was combined with real-time aerial chemical analysis. The results of the comparison indicate that a limited group of models (7-8) were capable of obtaining a good reproduction of the cloud movement throughout Europe for the first release. Large differences were, however, found in the predicted tracer concentration at a particular location. For the second release, there were large differences between the measured and calculated cloud, particularly after a front passage, which indicates that some efforts have still to be spent before consensus on the model reliability is achieved. (P.A.)

  11. Molecular dynamics investigation of tracer diffusion in a simple liquid

    International Nuclear Information System (INIS)

    Ould-Kaddour, F.; Barrat, J.L.

    1991-05-01

    Extensive Molecular-Dynamics (MD) simulations have been carried out for a model trace-solvent system made up of 100 solvent molecules and 8 tracer molecules interacting through truncated Lennard-Jones potentials. The influence of the size ratio between solute and solvent, of their mass ratio and of the solvent viscosity on the diffusivity of a small tracer were investigated. Positive deviations from a Stokes-Einstein behaviour are observed, in qualitative agreement with experimental observations. It was also observed that as tracer and solvent become increasingly dissimilar, their respective dynamics becomes decoupled. We suggest that such decouplings can be interpreted by writing their mobility of the tracer as the sum of two terms, the first one arising from a coupling between tracer dynamics and hydrodynamics modes of the solvent, and the second one describing jump motion in a locally nearly frozen environment. (author). 17 refs, 4 figs, 6 tabs

  12. Geologic flow characterization using tracer techniques

    International Nuclear Information System (INIS)

    Klett, R.D.; Tyner, C.E.; Hertel, E.S. Jr.

    1981-04-01

    A new tracer flow-test system has been developed for in situ characterization of geologic formations. This report describes two sets of test equipment: one portable and one for testing in deep formations. Equations are derived for in situ detector calibration, raw data reduction, and flow logging. Data analysis techniques are presented for computing porosity and permeability in unconfined isotropic media, and porosity, permeability and fracture characteristics in media with confined or unconfined two-dimensional flow. The effects of tracer pulse spreading due to divergence, dispersion, and porous formations are also included

  13. Guidebook on radioisotope tracers in industry

    International Nuclear Information System (INIS)

    1990-01-01

    The idea of using tracers (chemical, dyes, etc.) in the investigation of complex physical phenomena has always attracted the attention of scientists and engineers. When radioactive isotopes became available it was immediately recognized that they offered an almost ideal solution to tracer selection. This book is devoted to reviewing the present status of the tracer method as such and to its applications to those branches of industry which have derived large benefits from the use of this modern technology. The main objectives of the IAEA's Industrial Applications and Chemistry Section is to help Member States in introducing to their own industries the different isotope and radiation techniques which have become available as a result of developments in the nuclear sciences. This section proposed the preparation of this guidebook, putting together various radiotracer methods and the experience obtained so far in their industrial use. Chapters 2 to 4 cover the general concept of tracers, technology and safety aspects, as well as data evaluation and interpretation. In chapter 5, therefore, general applications are discussed. In chapter 6, specialists in selected fields discuss their experience in radiotracer applications in various types of industrial activity. Most case studies are illustrated by at least one detailed example of an experiment carried out at an industrial installation. Current trends in the development of radiotracer methods are discussed in chapter 7, from both a theoretical and a practical viewpoint. Some possible new RTT applications in the future are also discussed here. Sealed radioactive sources are used almost as often as radioisotope tracers in industrial measurements. Annex I gives a short review of these techniques. Readers who are interested in the basic principles of radioisotope production will find the necessary information in Annex II. Annexes III, V and VI provide a demonstration of fundamental relations and properties; useful

  14. Tracer-based quantification of individual frac discharge in single-well multiple-frac backflow: sensitivity study

    Science.gov (United States)

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2014-05-01

    a simplified flow and tracer transport model (using FEOW and assuming Darcian flow within the matrix, Hagen-Poiseuille flow within the waterfrac, and either D or H-P flow within the gel-proppant fracs), whose main findings are: (1) late tracer signals are almost independent on matrix porosity, permeability distribution, frac area (length), thickness and effective aperture, while being highly sensitive to local discharge values; 'late' means a backflow or production volume at least fivefold the injected chaser volume; (2a) early tracer signals (concentration 'peak' intervals) may exhibit slight 'acceleration' and 'damping' with increasing matrix porosity or increasing frac aperture (a 'paradoxical' behaviour which is not really surprising for single-well 'push-then-backflow' tests, actually owing to flow-field dispersion[4]), and (2b) a non-monotonous response to varying frac area, being almost insensitive to frac area as long as the linear-flow regime prevails against the radial-flow regime (effects of the latter only becoming visible at very low frac areas); (2c) the effects of these various factors on early-time tracer signals are not unambiguously discernible from each other, and this ambiguity would persist even if frac-resolved (in-situ) discharge metering were feasible. For each of the three fracs (k=1,2,3), a 'type-curve' set Ck(Q,t) (parametrized by discharge values Q) can be generated. Since every frac received a different tracer, tracer signals measured within the overall backflow will differ from individual-frac type-curves by mere dilution (no 'superposition'). Type-curve dilution by factor Qk/Qtotal can be compared to measured tracer concentrations in the total discharge, ck(ti), (i = 1, ..., no. of tracer samplings). From a formal point of view, the unknown discharge values Qk can be determined as the solution of a linear optimization task subject to the constraint Q1 + Q2 + Q3 = Qtotal (the latter being a measured value). It is recommendable to

  15. First preclinical evaluation of mono-[123I]iodohypericin as a necrosis-avid tracer agent

    International Nuclear Information System (INIS)

    Ni, Yicheng; Chen, Feng; Marchal, Guy; Huyghe, Dieter; Verbeke, Kristin; Verbruggen, Alfons M.; Bormans, Guy M.; Witte, Peter A. de; Nuyts, Johan; Mortelmans, Luc

    2006-01-01

    We have labelled hypericin, a polyphenolic polycyclic quinone found in St. John's wort (Hypericum perforatum), with 123 I and evaluated mono-[ 123 I]iodohypericin (MIH) as a potential necrosis-avid diagnostic tracer agent. MIH was prepared by an electrophilic radioiodination method. The new tracer agent was evaluated in animal models of liver infarction in the rat and heart infarction in the rabbit using single-photon emission computed tomography (SPECT), triphenyltetrazolium chloride (TTC) histochemical staining, serial sectional autoradiography and microscopy, and radioactivity counting techniques. Using in vivo SPECT imaging, hepatic and cardiac infarctions were persistently visualised as well-defined hot spots over 48 h. Preferential uptake of the tracer agent in necrotic tissue was confirmed by perfect match of images from post-mortem TTC staining, autoradiography (ARX) and histology. Radioactivity concentration in infarcted tissues was over 10 times (liver; 3.51% ID/g in necrotic tissue vs 0.38% ID/g in normal tissue at 60 h p.i.) and over 6 times (myocardium; 0.36% ID/g in necrotic tissue vs 0.054% ID/g in normal tissue; ratios up to 18 for selected parts on ARX images) higher than in normal tissues. The results suggest that hypericin derivatives may serve as powerful necrosis-avid diagnostic agents for assessment of tissue viability. (orig.)

  16. Recover Act. Verification of Geothermal Tracer Methods in Highly Constrained Field Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Matthew W. [California State University, Long Beach, CA (United States)

    2014-05-16

    pumping tests in identifying a poorly connected well. As a result, we were able to predict which well pairs would demonstrate channelized flow. The focus of the tracer investigation was multi-ionic tests. In multi-ionic tests several ionic tracers are injected simultaneously and the detected in a nearby pumping well. The time history of concentration, or breakthrough curve, will show a separation of the tracers. Anionic tracers travel with the water but cationic tracer undergo chemical exchange with cations on the surface of the rock. The degree of separation is indicative of the surface area exposed to the tracer. Consequently, flow channelization will tend to decrease the separation in the breakthrough. Estimation of specific surface area (the ration of fracture surface area to formation volume) is performed through matching the breakthrough curve with a transport model. We found that the tracer estimates of surface area were confirmed the prediction of channelized flow between well pairs produced by the periodic hydraulic tests. To confirm that the hydraulic and tracer tests were correctly predicting channelize flow, we imaged the flow field using surface GPR. Saline water was injected between the well pairs which produced a change in the amplitude and phase of the reflected radar signal. A map was produced of the migration of saline tracer from these tests which qualitatively confirmed the flow channelization predicted by the hydraulic and tracer tests. The resolution of the GPR was insufficient to quantitatively estimate swept surface area, however. Surface GPR is not applicable in typical geothermal fields because the penetration depths do not exceed 10’s of meters. Nevertheless, the method of using of phase to measure electrical conductivity and the assessment of antennae polarization represent a significant advancement in the field of surface GPR. The effect of flow character on fracture / rock thermal exchange was evaluated using heated water as a tracer. Water

  17. Effect of Chinese traditional medicine anti-fatigue prescription on the concentration of the serum testosterone and cortisol in male rats under stress of maximum intensive training

    International Nuclear Information System (INIS)

    Dong Ling; Si Xulan

    2008-01-01

    Objective: To study the effect of chinese traditional medicine anti-fatigue prescription on the concentration of the serum testosterone (T) and cortisol (C) in male rats under the stress of maximum intensive training. Methods: Wistar male rat models of stress under maximum intensity training were established (n=40) and half of them were treated with Chinese traditional medicine anti-fatigue prescription twenty undisturbed rats served as controls. Testosterone and cortisol serum levels were determined with RIA at the end of the seven weeks' experiment. Results: Maximum intensive training would cause the level of the serum testosterone lowered, the concentration of the cortisol elevated and the ratio of T/C reduced. The serum T levels and T/C ratio were significantly lower and cortisol levels significantly higher in the untreated models than those in the treated models and controls (P<0.01). The levels of the two hormones were markedly corrected in the treated models with no significantly differences from those in the controls. However, the T/C ratio was still significantly lower than that in the controls (P <0.05) due to a relatively slightly greater degree of reduction of T levels. Conclusion: Anti-fatigue prescription can not only promote the recovery of fatigue after the maximum intensive training but also strengthen the anabolism of the rats. (authors)

  18. Low-cost, High Flexibility I-V Curve Tracer for Photovoltaic Modules

    DEFF Research Database (Denmark)

    Ibirriaga, Julen Joseba Maestro; Pena, Xabier Miquelez de Mendiluce; Opritescu, Adrian

    2010-01-01

    This work presents the design, construction and test of an in-door low cost, high flexibility I-V curve tracer for photovoltaic modules. The tracer is connected to a Xenon lamp based flashing solar simulator. The designed tracer is able to deal with the very fast changing irradiation conditions...

  19. Our experience of blood flow measurements using radioactive tracers

    International Nuclear Information System (INIS)

    Danet, Bernard.

    1974-01-01

    A critical study of blood flow measuring methods is proposed. After a review of the various diffusible and non-diffusible radioactive tracers and the corresponding detector systems, the principles which allow to measure blood flow from the data so obtained, are studied. There is a different principle of flow measurement for each type of tracer. The theory of flow measurement using non-diffusible tracers (human serum albumin labelled with 131 I or sup(99m)Tc, 113 In-labelled siderophiline) and its application to cardiac flow measurement are described first. Then the theory of flow measurement using diffusible tracers ( 133 Xe, 85 Kr) and its application to measurement of blood flow through tissues (muscles and kidney particularly) are described. A personal experience of this various flow measurements is reported. The results obtained, the difficulties encountered and the improvments proposed are developed [fr

  20. Analysis of infiltration through mill tailings using a bromide tracer

    International Nuclear Information System (INIS)

    Lewis, G.J.; Stephens, D.B.

    1985-01-01

    Infiltration of precipitation into tailings impoundments as a means of recharge to underlying materials is often considered insignificant, particularly in arid and semi-arid environments. A series of experiments was performed to investigate the behavior of infiltrated precipitation into tailing soils, by the use of a bromide tracer. A bromide tracer was applied to the surface of columns driven into the tailings to monitor downward advancement of tracer-laden water. Controlled laboratory experiments on the behavior of the bromide tracer under varying precipitation events and initial soil moisture contents were also conducted. Results indicate that a definite downward migration of infiltrated precipitation occurs, particularly with large magnitude precipitation events, and that, eventually, some fraction of the infiltrated precipitation may continue downward below the zone affected by evaporation. The use of an artificially applied bromide tracer to monitor depth of infiltration of precipitation is a simple, safe technique that can provide valuable information for long-term tailings management strategies at low cost

  1. Bayesian inverse modeling of the atmospheric transport and emissions of a controlled tracer release from a nuclear power plant

    International Nuclear Information System (INIS)

    Lucas, Donald D.; Simpson, Matthew; Cameron-Smith, Philip; Baskett, Ronald L.

    2017-01-01

    Probability distribution functions (PDFs) of model inputs that affect the transport and dispersion of a trace gas released from a coastal California nuclear power plant are quantified using ensemble simulations, machine-learning algorithms, and Bayesian inversion. The PDFs are constrained by observations of tracer concentrations and account for uncertainty in meteorology, transport, diffusion, and emissions. Meteorological uncertainty is calculated using an ensemble of simulations of the Weather Research and Forecasting (WRF) model that samples five categories of model inputs (initialization time, boundary layer physics, land surface model, nudging options, and reanalysis data). The WRF output is used to drive tens of thousands of FLEXPART dispersion simulations that sample a uniform distribution of six emissions inputs. Machine-learning algorithms are trained on the ensemble data and used to quantify the sources of ensemble variability and to infer, via inverse modeling, the values of the 11 model inputs most consistent with tracer measurements. We find a substantial ensemble spread in tracer concentrations (factors of 10 to 10 3 ), most of which is due to changing emissions inputs (about 80 %), though the cumulative effects of meteorological variations are not negligible. The performance of the inverse method is verified using synthetic observations generated from arbitrarily selected simulations. When applied to measurements from a controlled tracer release experiment, the inverse method satisfactorily determines the location, start time, duration and amount. In a 2 km x 2 km area of possible locations, the actual location is determined to within 200 m. The start time is determined to within 5 min out of 2 h, and the duration to within 50 min out of 4 h. Over a range of release amounts of 10 to 1000 kg, the estimated amount exceeds the actual amount of 146 kg by only 32 kg. The inversion also estimates probabilities of different WRF configurations. To best match

  2. Bayesian inverse modeling of the atmospheric transport and emissions of a controlled tracer release from a nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Lucas, Donald D.; Simpson, Matthew; Cameron-Smith, Philip; Baskett, Ronald L. [Lawrence Livermore National Laboratory, Livermore, CA (United States)

    2017-07-01

    Probability distribution functions (PDFs) of model inputs that affect the transport and dispersion of a trace gas released from a coastal California nuclear power plant are quantified using ensemble simulations, machine-learning algorithms, and Bayesian inversion. The PDFs are constrained by observations of tracer concentrations and account for uncertainty in meteorology, transport, diffusion, and emissions. Meteorological uncertainty is calculated using an ensemble of simulations of the Weather Research and Forecasting (WRF) model that samples five categories of model inputs (initialization time, boundary layer physics, land surface model, nudging options, and reanalysis data). The WRF output is used to drive tens of thousands of FLEXPART dispersion simulations that sample a uniform distribution of six emissions inputs. Machine-learning algorithms are trained on the ensemble data and used to quantify the sources of ensemble variability and to infer, via inverse modeling, the values of the 11 model inputs most consistent with tracer measurements. We find a substantial ensemble spread in tracer concentrations (factors of 10 to 10{sup 3}), most of which is due to changing emissions inputs (about 80 %), though the cumulative effects of meteorological variations are not negligible. The performance of the inverse method is verified using synthetic observations generated from arbitrarily selected simulations. When applied to measurements from a controlled tracer release experiment, the inverse method satisfactorily determines the location, start time, duration and amount. In a 2 km x 2 km area of possible locations, the actual location is determined to within 200 m. The start time is determined to within 5 min out of 2 h, and the duration to within 50 min out of 4 h. Over a range of release amounts of 10 to 1000 kg, the estimated amount exceeds the actual amount of 146 kg by only 32 kg. The inversion also estimates probabilities of different WRF configurations. To best

  3. Estimation of the dilution field near a marine outfall by using effluent turbidity as an environmental tracer and comparison with dye tracer data.

    Science.gov (United States)

    Pecly, José Otavio Goulart

    2018-01-01

    The alternative use of effluent turbidity to determine the dilution field of a domestic marine outfall located off the city of Rio de Janeiro was evaluated through field work comprising fluorescent dye tracer injection and tracking with simultaneous monitoring of sea water turbidity. A preliminary laboratory assessment was carried out with a sample of the outfall effluent whose turbidity was measured by the nephelometric method before and during a serial dilution process. During the field campaign, the dye tracer was monitored with field fluorometers and the turbidity was observed with an optical backscattering sensor interfaced to an OEM data acquisition system. About 4,000 samples were gathered, covering an area of 3 km × 3 km near the outfall diffusers. At the far field - where a drift towards the coastline was observed - the effluent plume was adequately labeled by the dye tracer. The turbidity plume was biased due to the high and variable background turbidity of sea water. After processing the turbidity dataset with a baseline detrending method, the plume presented high correlation with the dye tracer plume drawn on the near dilution field. However, dye tracer remains more robust than effluent turbidity.

  4. Tracer gas diffusion sampling test plan

    International Nuclear Information System (INIS)

    Rohay, V.J.

    1993-01-01

    Efforts are under way to employ active and passive vapor extraction to remove carbon tetrachloride from the soil in the 200 West Area an the Hanford Site as part of the 200 West Area Carbon Tetrachloride Expedited Response Action. In the active approach, a vacuum is applied to a well, which causes soil gas surrounding the well to be drawn up to the surface. The contaminated air is cleaned by passage through a granular activated carbon bed. There are questions concerning the radius of influence associated with application of the vacuum system and related uncertainties about the soil-gas diffusion rates with and without the vacuum system present. To address these questions, a series of tracer gas diffusion sampling tests is proposed in which an inert, nontoxic tracer gas, sulfur hexafluoride (SF 6 ), will be injected into a well, and the rates of SF 6 diffusion through the surrounding soil horizon will be measured by sampling in nearby wells. Tracer gas tests will be conducted at sites very near the active vacuum extraction system and also at sites beyond the radius of influence of the active vacuum system. In the passive vapor extraction approach, barometric pressure fluctuations cause soil gas to be drawn to the surface through the well. At the passive sites, the effects of barometric ''pumping'' due to changes in atmospheric pressure will be investigated. Application of tracer gas testing to both the active and passive vapor extraction methods is described in the wellfield enhancement work plan (Rohay and Cameron 1993)

  5. Models for tracer flow

    International Nuclear Information System (INIS)

    Zuber, A.

    1983-01-01

    A review and discussion is given of mathematical models used for interpretation of tracer experiments in hydrology. For dispersion model, different initial and boundary conditions are related to different injection and detection modes. Examples of applications of various models are described and commented. (author)

  6. The use of C-14 as tracer in the carbon flow assimilated by the plants (maize, sugar cane, bean)

    International Nuclear Information System (INIS)

    Paula Eduardo, B. de; Cerri, C.C.

    1988-01-01

    The flow of carbon in three different crops (maize, beans and sugar cane) was studied by use of C-14. The plants were exposed to an atmosphere with a constant concentration of the tracer for 12 hours in a biosynthesis chamber. The detection of the isotope permitted the distribution and concentration of the photosynthetates in the various organs of the plants to be followed. (M.A.C.) [pt

  7. Tracer techniques in food industry

    International Nuclear Information System (INIS)

    Pertsovskij, E.S.; Sakharov, Eh.V.; Dolinin, V.A.

    1980-01-01

    The appicability of radioactive tracer techniques to process control in food industry are considered. Investigations in the field of food industry carried out using the above method are classified. The 1 class included investigations with preliminary preparation of a radioactive indicator and its following introduction in the system studied. The 2 class includes investigations based on the introduction in the system studied of a non-active indicator which is activated in a neutron flux being in samples selected in or after the process investigated. The 3 class includes studies based on investigations of natural radioactivity of certain nuclides in food stuff. The application of tracer techniques to the above classes of investigations in various fields of food industry and the equipment applied are considered in detail [ru

  8. Does carbon isotope data help explain atmospheric CO2 concentrations during glacial periods?

    International Nuclear Information System (INIS)

    Alverson, K.; Le Grand, P.

    2002-01-01

    An inverse ocean box modeling approach is used to address the question of what may have caused decreased atmospheric CO 2 concentration during glacial periods. The inverse procedure seeks solutions that are consistent, within prescribed uncertainties, with both available paleodata constraints and box model conservation equations while relaxing traditional assumptions such as exact steady state and precise prescription of uncertain model parameters. Decreased ventilation of Southern Ocean deep water, decreased Southern Ocean air-sea gas exchange, and enhanced high latitude biological pumping are all shown to be individually capable of explaining available paleodata constraints provided that significant calcium carbonate compensation is allowed. None of the scenarios require more than a very minor (order 1 deg. C) glacial reduction in low to mid latitude sea surface temperature although scenarios with larger changes are equally plausible. One explanation for the fairly wide range of plausible solutions is that most paleo-data directly constrain the inventory of paleo-tracers but only indirectly constrain their fluxes. Because the various scenarios that have been proposed to explain pCO 2 levels during the last glacial maximum are distinguished primarily by different fluxes, the data, including ocean 13 C concentrations, do not allow one to confidently chose between them. Oceanic 14 C data for the last glacial maximum, which can constrain water mass fluxes, present an excellent potential solution to this problem if their reliability is demonstrated in the future. (author)

  9. Assessing preferential flow by simultaneously injecting nanoparticle and chemical tracers

    KAUST Repository

    Subramanian, S. K.; Li, Yan; Cathles, L. M.

    2013-01-01

    The exact manner in which preferential (e.g., much faster than average) flow occurs in the subsurface through small fractures or permeable connected pathways of other kinds is important to many processes but is difficult to determine, because most chemical tracers diffuse quickly enough from small flow channels that they appear to move more uniformly through the rock than they actually do. We show how preferential flow can be assessed by injecting 2 to 5 nm carbon particles (C-Dots) and an inert KBr chemical tracer at different flow rates into a permeable core channel that is surrounded by a less permeable matrix in laboratory apparatus of three different designs. When the KBr tracer has a long enough transit through the system to diffuse into the matrix, but the C-Dot tracer does not, the C-Dot tracer arrives first and the KBr tracer later, and the separation measures the degree of preferential flow. Tracer sequestration in the matrix can be estimated with a Peclet number, and this is useful for experiment design. A model is used to determine the best fitting core and matrix dispersion parameters and refine estimates of the core and matrix porosities. Almost the same parameter values explain all experiments. The methods demonstrated in the laboratory can be applied to field tests. If nanoparticles can be designed that do not stick while flowing through the subsurface, the methods presented here could be used to determine the degree of fracture control in natural environments, and this capability would have very wide ranging value and applicability.

  10. Multi-tracer investigation of river and groundwater interactions: a case study in Nalenggele River basin, northwest China

    Science.gov (United States)

    Xu, Wei; Su, Xiaosi; Dai, Zhenxue; Yang, Fengtian; Zhu, Pucheng; Huang, Yong

    2017-11-01

    Environmental tracers (such as major ions, stable and radiogenic isotopes, and heat) monitored in natural waters provide valuable information for understanding the processes of river-groundwater interactions in arid areas. An integrated framework is presented for interpreting multi-tracer data (major ions, stable isotopes (2H, 18O), the radioactive isotope 222Rn, and heat) for delineating the river-groundwater interactions in Nalenggele River basin, northwest China. Qualitative and quantitative analyses were undertaken to estimate the bidirectional water exchange associated with small-scale interactions between groundwater and surface water. Along the river stretch, groundwater and river water exchange readily. From the high mountain zone to the alluvial fan, groundwater discharge to the river is detected by tracer methods and end-member mixing models, but the river has also been identified as a losing river using discharge measurements, i.e. discharge is bidirectional. On the delta-front of the alluvial fan and in the alluvial plain, in the downstream area, the characteristics of total dissolved solids values, 222Rn concentrations and δ18O values in the surface water, and patterns derived from a heat-tracing method, indicate that groundwater discharges into the river. With the environmental tracers, the processes of river-groundwater interaction have been identified in detail for better understanding of overall hydrogeological processes and of the impacts on water allocation policies.

  11. Use of radioactive tracers in chemical reactions

    International Nuclear Information System (INIS)

    Paci, B.

    1979-01-01

    A method for the determination of small quantities of nickel using radioactive tracers is presented. An analytical application of the displacement reaction between nickel and zinc ethylenediaminetetraacetate labeled with zinc-65 is pursued. This method is based on the extraction of radioactive zinc displaced by nickel from the zinc chelate into a dithizone-carbon tetracloride solution and the subsequent measurement of the activity of an aliquot of the extract. The method is very sensitive and nickel can be measured in concentrations as small as 0.1μg/ml or even less, depending on the specific activity of the radioreagent used. The precision and the accuracy of the method are determined. The problem of interferences, trying to eliminate them by using masking agents or by means of a previous separation between nickel and other interfering metals, is also investigated [pt

  12. Developing multi-tracer approaches to constrain the parameterisation of leaf and soil CO2 and H2O exchange in land surface models

    Science.gov (United States)

    Ogée, Jerome; Wehr, Richard; Commane, Roisin; Launois, Thomas; Meredith, Laura; Munger, Bill; Nelson, David; Saleska, Scott; Zahniser, Mark; Wofsy, Steve; Wingate, Lisa

    2016-04-01

    The net flux of carbon dioxide between the land surface and the atmosphere is dominated by photosynthesis and soil respiration, two of the largest gross CO2 fluxes in the carbon cycle. More robust estimates of these gross fluxes could be obtained from the atmospheric budgets of other valuable tracers, such as carbonyl sulfide (COS) or the carbon and oxygen isotope compositions (δ13C and δ18O) of atmospheric CO2. Over the past decades, the global atmospheric flask network has measured the inter-annual and intra-annual variations in the concentrations of these tracers. However, knowledge gaps and a lack of high-resolution multi-tracer ecosystem-scale measurements have hindered the development of process-based models that can simulate the behaviour of each tracer in response to environmental drivers. We present novel datasets of net ecosystem COS, 13CO2 and CO18O exchange and vertical profile data collected over 3 consecutive growing seasons (2011-2013) at the Harvard forest flux site. We then used the process-based model MuSICA (multi-layer Simulator of the Interactions between vegetation Canopy and the Atmosphere) to include the transport, reaction, diffusion and production of each tracer within the forest and exchanged with the atmosphere. Model simulations over the three years captured well the impact of diurnally and seasonally varying environmental conditions on the net ecosystem exchange of each tracer. The model also captured well the dynamic vertical features of tracer behaviour within the canopy. This unique dataset and model sensitivity analysis highlights the benefit in the collection of multi-tracer high-resolution field datasets and the developement of multi-tracer land surface models to provide valuable constraints on photosynthesis and respiration across scales in the near future.

  13. Effect of certain variables on the tumor and tissue distribution of tracers. III. Salicylates and vasoactive drugs

    International Nuclear Information System (INIS)

    Halpern, S.E.; Hagan, P.; Stern, P.; Gordon, R.; Dabbs, J.

    1981-01-01

    Attempts were made to increase the viable tumor concentration of 54 Mn and 67 Ga in a rat hepatoma model by administering rat angiotensin, tolazoline, and salicylates. Salicylates increased the tumor concentrations of 54 Mn and improved 65 Mn viable tumor/background ratios. 67 Ga was not affected by the salicylates. The salicylate effect appeared to be mediated by intracellular mechanisms rather than alterations in plasma protein binding. Rat angiotensin slightly increased the concentrations of 67 Ga in the tumors but not enough to suggest that it would be useful clinically. Tolazoline did not increase tumor uptake of the tracers

  14. Busted Butte Phase 2: Introduction and Analytical Modeling of Nonreactive Tracer and Lithium Breakthrough

    International Nuclear Information System (INIS)

    Turin, H.J.; Soll, W.E.

    2002-01-01

    The Busted Butte Unsaturated-Zone Transport Test Facility is located approximately 8 km southeast of Yucca Mountain, and was designed to address uncertainties associated with flow and transport in the UZ site-process models for Yucca Mountain. Busted Butte Phase 2 consisted of a 10m x 10m x 7m test block. From July 1988 through October 2000, complex tracer mixtures were injected continuously at 77 discrete points located along eight parallel 10-m boreholes arranged in two horizontal planes. In August 1999, iodide was added to the tracer mixture to explore the effects of initial hydraulic transients. During the course of the experiment, porewater samples were collected at regular intervals using sorbing-paper collection pads, emplaced into fifteen horizontal and inclined 10-m collection boreholes, oriented perpendicular to the injection boreholes. Potential travel distances ranged from 20 cm to over 500 cm. Nonreactive tracer and weakly sorbing lithium breakthrough was observed at most of the collection points during the injection period. Following termination of injection, approximately 800 rock samples were collected using overcore and mineback techniques, and analyzed for tracer concentration. Rock analyses are discussed in a subsequent paper. To complement complex 3-dimensional finite-element modeling of the entire block, bromide, iodide, and lithium breakthrough onto the collection pads has been modeled with CXTFIT. This simple 1-dimensional analytical code uses a non-linear curve-fitting routine to estimate transport parameters including apparent velocity, dispersivity, and field retardation factors. Preliminary results show that: (1) Bromide and iodide behaved similarly, despite the fact that bromide was injected in a strongly transient flow field, while iodide injection began after flow had approached steady state conditions. (2) With the exception of the closest collection points, tracer velocities remained relatively constant, indicating that transport was

  15. Radioimmunoassay of bovine, ovine and porcine luteinizing hormone with a monoclonal antibody and a human tracer

    Energy Technology Data Exchange (ETDEWEB)

    Fosberg, M; Tagle, R; Madej, A; Molina, J R; Carlsson, M -A

    1993-01-01

    A radioimmunoassay for bovine (bLH), ovine (oLH) and porcine (pLH) luteinizing hormone was developed using a human [sup 125]ILH tracer from a commercial kit and a monoclonal antibody (518B7) specific for LH but with low species specificity. Standard curves demonstrated similar binding kinetics when bLH, oLH and pLH were incubated with tracer and antibody for 2 h at room temperature. A 30-min delay in the addition of the tracer gave sufficient sensitivity when analysing pLH. Separation of antibody-bound LH from free hormone was achieved by using second antibody-coated micro Sepharose beads. The assay was validated and the performance compared with that of an RIA currently in use for determination of bLH (coefficient of correlation: 0.99 and 0.98). Regardless of the standards used, intra-assay coefficients of variation were <10% for LH concentrations exceeding 1 [mu]g/L. The inter-assay coefficients of variation were <15%. The assay was used for clinical evaluation demonstrating the pre-ovulatory LH surge in two cyclic cows, LH pulsatility in an oophorectomized ewe and LH response to GnRH injection in a boar. (au) (7 refs.).

  16. Development of radioisotope tracer technology and nucleonic control system

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Joon Ha; Lee, Myun Joo; Jung, Sung Hee and others

    1999-04-01

    The purpose of this study is to develop the radioisotope tracer technology, which can be used in solving industrial and environmental problems and basic technology of nuclear control systems that are widely used for automation of industrial plants, and to build a strong tracer group to support the local industries. In relation to the tracer technology, the data acquisition system, the column scanning equipment and the detection pig for a leakage test have been developed. In order to use in analyzing data of tracer experiments, a computer program for the analysis of residence time distribution has been created as well. These results were utilized in developing the tracer technologies, such as the column scanning, the flow measurement using the dilution method, the simultaneous monitoring rotational movement of piston rings and the optimization of a waste water treatment facility, and the technologies were successfully demonstrated in the local industrial. The stripper of RFCC reactor has been examined to find an unwanted structure in it by imminent request from the industry. Related to the development of nucleonic control system, the state of art report on the technology has been written and an equipment for the analysis of asphalt content has been developed. (author)

  17. An improved method for analysis of In-EDTA, I- and Br- used as active tracers in hydrological studies

    International Nuclear Information System (INIS)

    Stanescu, S.P.; Spiridon, S.

    1992-01-01

    Neutron activation analysis combined with chemical preconcentration of the elements in water samples can give a high sensitivity in the determination of concentrations for In-EDTA, I - and Br - used as active tracers in hydrological studies. The authors have developed an improved method of analysis which is sensitive, selective and applicable to a wide range of underground and surface water samples including those having a high concentration of manganese ions. (author) 6 refs.; 2 figs.; 1 tab

  18. Flow visualization in superfluid helium-4 using He2 molecular tracers

    Science.gov (United States)

    Guo, Wei

    Flow visualization in superfluid helium is challenging, yet crucial for attaining a detailed understanding of quantum turbulence. Two problems have impeded progress: finding and introducing suitable tracers that are small yet visible; and unambiguous interpretation of the tracer motion. We show that metastable He2 triplet molecules are outstanding tracers compared with other particles used in helium. These molecular tracers have small size and relatively simple behavior in superfluid helium: they follow the normal fluid motion at above 1 K and will bind to quantized vortex lines below about 0.6 K. A laser-induced fluorescence technique has been developed for imaging the He2 tracers. We will present our recent experimental work on studying the normal-fluid motion by tracking thin lines of He2 tracers created via femtosecond laser-field ionization in helium. We will also discuss a newly launched experiment on visualizing vortex lines in a magnetically levitated superfluid helium drop by imaging the He2 tracers trapped on the vortex cores. This experiment will enable unprecedented insight into the behavior of a rotating superfluid drop and will untangle several key issues in quantum turbulence research. We acknowledge the support from the National Science Foundation under Grant No. DMR-1507386 and the US Department of Energy under Grant No. DE-FG02 96ER40952.

  19. Predictions of PuO2 and tracer compound release from ISV melts

    International Nuclear Information System (INIS)

    Cronenberg, A.W.; Callow, R.A.

    1992-04-01

    Two field tests were conducted at the Idaho National Engineering Laboratory (INEL) to assess in situ vitrification (ISV) suitability for long-term stabilization of buried radioactive waste. Both tests contained rare-earth oxide tracers (DY 2 O 3 , Yb 2 O 3 , and Tb 4 O 7 ) to simulate the presence of plutonium in the form of PuO 2 . In the first test, Intermediate Field Test (IFT)-l, approximately 4-% release of tracer material occurred during soil melting and associated off-gassing, while essentially nil release was observed for the second experiment (IFT-2) for which off-gassing was much reduced. This report presents an evaluation of the IFT test data in terms of governing release processes. Prediction of tracer release during ISV melting centered on an assessment of three potential transport mechanisms, (a) tracer diffusion through stagnant pool, (b) tracer transport by convective currents, and (c) tracer carry-off by escaping gas bubbles. Analysis indicates that tracer release by escaping gas is the dominant release mechanism, which is consistent with video records of gas bubble escape from the ISV melt surface. Quantitative mass transport predictions were also made for the IFT-I test conditions, indicating similarity between the 4-% release data and calculational results at viscosities of ∼ poise and tracer diffusivities of ∼10 -6 CM 2 /s. Since PuO 2 has similar chemical and transport (diffusivity) properties as the rare-earth tracers used in the rare earth tracers used in the IFT experiments, release of PuO 2 is predicted for similar off-gassing conditions. Reduced off-gassing during ISV would thus be expected to improve the overall retention of heavy-oxides within vitrified soil

  20. Development of Models to Simulate Tracer Tests for Characterization of Enhanced Geothermal Systems

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Mark D.; Reimus, Paul; Vermeul, Vincent R.; Rose, Peter; Dean, Cynthia A.; Watson, Tom B.; Newell, D.; Leecaster, Kevin; Brauser, Eric

    2013-05-01

    A recent report found that power and heat produced from enhanced (or engineered) geothermal systems (EGSs) could have a major impact on the U.S energy production capability while having a minimal impact on the environment. EGS resources differ from high-grade hydrothermal resources in that they lack sufficient temperature distribution, permeability/porosity, fluid saturation, or recharge of reservoir fluids. Therefore, quantitative characterization of temperature distributions and the surface area available for heat transfer in EGS is necessary for the design and commercial development of the geothermal energy of a potential EGS site. The goal of this project is to provide integrated tracer and tracer interpretation tools to facilitate this characterization. This project was initially focused on tracer development with the application of perfluorinated tracer (PFT) compounds, non-reactive tracers used in numerous applications from atmospheric transport to underground leak detection, to geothermal systems, and evaluation of encapsulated PFTs that would release tracers at targeted reservoir temperatures. After the 2011 midyear review and subsequent discussions with the U.S. Department of Energy Geothermal Technology Program (GTP), emphasis was shifted to interpretive tool development, testing, and validation. Subsurface modeling capabilities are an important component of this project for both the design of suitable tracers and the interpretation of data from in situ tracer tests, be they single- or multi-well tests. The purpose of this report is to describe the results of the tracer and model development for simulating and conducting tracer tests for characterizing EGS parameters.

  1. Hydraulic characterisation of karst systems with man-made tracers

    International Nuclear Information System (INIS)

    Werner, A.

    1998-01-01

    Tracer experiments using man-made tracers are common in hydrogeological exploration of groundwater aquifers in karst systems. In the present investigation, a convection-dispersion model (multidispersion model with consideration of several flow paths) and a single-cleft model (consideration of the diffusion between the cleft and the surrounding rock matrix) were used for evaluating tracer experiments in the main hydrological system of the saturated zone of karst systems. In addition to these extended analytical solutions, a numerical transport model was developed for investigating the influence of the transient flow rate on the flow and transport parameters. Comparative evaluations of the model approaches for the evaluation of tracer experiments were made in four different karst systems: Danube-Aach, Paderborn, Slowenia and Lurbach, of which the Danube-Aach system was considered as the most important. The investigation also comprised three supplementary experiments in order to enable a complete hydraulic characterisation of the system. (orig./SR) [de

  2. Vertical and horizontal resolution dependency in the model representation of tracer dispersion along the continental slope in the northern Gulf of Mexico

    Science.gov (United States)

    Bracco, Annalisa; Choi, Jun; Kurian, Jaison; Chang, Ping

    2018-02-01

    A set of nine regional ocean model simulations at various horizontal (from 1 to 9 km) and vertical (from 25 to 150 layers) resolutions with different vertical mixing parameterizations is carried out to examine the transport and mixing of a passive tracer released near the ocean bottom over the continental slope in the northern Gulf of Mexico. The release location is in proximity to the Deepwater Horizon oil well that ruptured in April 2010. Horizontal and diapycnal diffusivities are calculated and their dependence on the model set-up and on the representation of mesoscale and submesoscale circulations is discussed. Horizontal and vertical resolutions play a comparable role in determining the modeled horizontal diffusivities. Vertical resolution is key to a proper representation of passive tracer propagation and - in the case of the Gulf of Mexico - contributes to both confining the tracer along the continental slope and limiting its vertical spreading. The choice of the tracer advection scheme is also important, with positive definiteness in the tracer concentration being achieved at the price of spurious mixing across density surfaces. In all cases, however, the diapycnal mixing coefficient derived from the model simulations overestimates the observed value, indicating an area where model improvement is needed.

  3. Predictive value of tracer studies for 131I treatment in hyperthyroid cats

    International Nuclear Information System (INIS)

    Broome, M.R.; Turrel, J.M.; Hays, M.T.

    1988-01-01

    In 76 cats with hyperthyroidism, peak thyroidal radioiodine ( 131 I) uptakes and effective half-lives were determined after administration of tracer and therapeutic activities of 131 I. In 6 additional hyperthyroid cats, only peak thyroidal uptakes after administration of tracer and therapeutic activities of 131 I were determined. Good correlation was found between peak thyroidal uptakes of tracer and therapeutic 131 I; however, only fair correlation was observed between effective half-lives. In 79% of the cats, the effective half-life for therapeutic 131 I was longer than that for tracer 131 I. After administration of therapeutic activity of 131 I, monoexponential and biphasic decay curves were observed in 51 and 16 cats, respectively. Using therapeutic kinetic data, radiation doses to the thyroid gland were calculated retrospectively on the basis of 2 methods for determining the activity of 131 I administered: (1) actual administration of tracer-compensated activity and (2) hypothetic administration of uniform activity (3 mCi). Because of the good predictive ability of tracer kinetic data for the therapeutic kinetic data, the tracer-compensated radiation doses came significantly (P = 0.008) closer to the therapeutic goal than did the uniform-activity doses. In addition, the use of tracer kinetic information reduced the extent of the tendency for consistently high uniform-activity doses. A manual method for acquiring tracer kinetic data was developed and was an acceptable alternative to computerized techniques. Adoption of this method gives individuals and institutions with limited finances the opportunity to characterize the iodine kinetics in cats before proceeding with administration of therapeutic activities of 131 I

  4. Application of radioactive tracers in upgradation of industrial grade ion exchange resin (Amberlite IRA-400)

    International Nuclear Information System (INIS)

    Lokhande, R.S.; Singare, P.U.

    1998-01-01

    The exchange rates of ion exchange are determined by application of 131 I as a tracer isotope. The exchange study carried out in this investigation deals with understanding the effectiveness of ion exchange resin (in iodide form) Amberlite IRA-400 at different concentrations of potassium iodide solution (electrolyte) with temperature of solution varying from 27-48 degC by keeping amount of ion exchange resin constant (1.0 g). The exchange study is also carried out by varying amount of ion exchange resins, for fixed temperature (27.0 degC) and for fixed concentration of potassium iodide solution (0.005 M). (author)

  5. Evaluating 10B-enriched Boric Acid, Bromide, and Heat as Tracers of Recycled Groundwater Flow near MAR Operations

    Science.gov (United States)

    Becker, T.; Clark, J. F.

    2012-12-01

    County, CA, USA) has been in progress since September 6, 2011, following injection of boric acid enriched in boron-10 (10B) and bromide (Br-) tracers. Tracer concentrations are collected at 9 monitoring wells that have pre-experiment estimated travel times between 0.5 to 180 days. Results indicate that 10B-enriched boric acid is an effective deliberate tracer at MAR sites; however, the ion's movement is slightly retarded relative to bromide by the substrate. 10B/Br- travel time ratios range from 1 to 1.4. In addition to the two deliberate geochemical tracers, heat is being evaluated as a possible intrinsic tracer at MAR sites. At the time of the experiment (late summer), reclaimed water was significantly warmer (~20°F) than the native groundwater as it entered the system. Time series are developed from loggers outfitted at each monitoring well, with measurements recorded hourly accurate to one thousandth of a degree. Results are similar to 10B & Br- travel times and validate the potential of heat as an intrinsic tracer.

  6. Stable isotope tracers and exercise physiology: past, present and future.

    Science.gov (United States)

    Wilkinson, Daniel J; Brook, Matthew S; Smith, Kenneth; Atherton, Philip J

    2017-05-01

    Stable isotope tracers have been invaluable assets in physiological research for over 80 years. The application of substrate-specific stable isotope tracers has permitted exquisite insight into amino acid, fatty-acid and carbohydrate metabolic regulation (i.e. incorporation, flux, and oxidation, in a tissue-specific and whole-body fashion) in health, disease and response to acute and chronic exercise. Yet, despite many breakthroughs, there are limitations to 'substrate-specific' stable isotope tracers, which limit physiological insight, e.g. the need for intravenous infusions and restriction to short-term studies (hours) in controlled laboratory settings. In recent years significant interest has developed in alternative stable isotope tracer techniques that overcome these limitations, in particular deuterium oxide (D 2 O or heavy water). The unique properties of this tracer mean that through oral administration, the turnover and flux through a number of different substrates (muscle proteins, lipids, glucose, DNA (satellite cells)) can be monitored simultaneously and flexibly (hours/weeks/months) without the need for restrictive experimental control. This makes it uniquely suited for the study of 'real world' human exercise physiology (amongst many other applications). Moreover, using D 2 O permits evaluation of turnover of plasma and muscle proteins (e.g. dynamic proteomics) in addition to metabolomics (e.g. fluxomics) to seek molecular underpinnings, e.g. of exercise adaptation. Here, we provide insight into the role of stable isotope tracers, from substrate-specific to novel D 2 O approaches, in facilitating our understanding of metabolism. Further novel potential applications of stable isotope tracers are also discussed in the context of integration with the snowballing field of 'omic' technologies. © 2016 The Authors. The Journal of Physiology © 2016 The Physiological Society.

  7. The ATLAS DDM Tracer monitoring framework

    International Nuclear Information System (INIS)

    Zang Dongsong; Garonne, Vincent; Barisits, Martin; Lassnig, Mario; Andrew Stewart, Graeme; Molfetas, Angelos; Beermann, Thomas

    2012-01-01

    The DDM Tracer monitoring framework is aimed to trace and monitor the ATLAS file operations on the Worldwide LHC Computing Grid. The volume of traces has increased significantly since the framework was put in production in 2009. Now there are about 5 million trace messages every day and peaks can be near 250Hz, with peak rates continuing to climb, which gives the current structure a big challenge. Analysis of large datasets based on on-demand queries to the relational database management system (RDBMS), i.e. Oracle, can be problematic, and have a significant effect on the database's performance. Consequently, We have investigated some new high availability technologies like messaging infrastructure, specifically ActiveMQ, and key-value stores. The advantages of key value store technology are that they are distributed and have high scalability; also their write performances are usually much better than RDBMS, all of which are very useful for the Tracer monitoring framework. Indexes and distributed counters have been also tested to improve query performance and provided almost real time results. In this paper, the design principles, architecture and main characteristics of Tracer monitoring framework will be described and examples of its usage will be presented.

  8. Atmospheric Gas Tracers in Groundwater: Theory, Sampling. Measurement and Interpretation

    International Nuclear Information System (INIS)

    Bayari, C.S.

    2002-01-01

    Some of the atmospheric gasses posses features that are sought in an environmental tracer of hydrogeologic interest. Among these, chlorofluorocarbons, sulfur hegzafluoride, carbon tetrachloride, methyl chloroform, krypton-85 etc. have found increasing use in groundwater age dating studies during the last ten years. This paper explains the theory of their use as tracer and discusses the major concerns as related to their sampling and analyses. Factors affecting their applicability and the approach to interpret tracer gas data is briefly outlined

  9. Sistem Pre Kompilasi Data Tracer Studi Online Ditjen Belmawa Ristekdikti (Studi Kasus: Politeknik Harapan Bersama

    Directory of Open Access Journals (Sweden)

    Very Kurnia Bakti

    2017-01-01

    Full Text Available Tracer studi merupakan salah satu upaya yang diharapkan dapat menyediakan informasi untuk mengevaluasi hasil pendidikan di Politeknik Harapan Bersama dari kuisioner yang diberikan kepada alumni. Kegiatan tracer studi ini sudah dilaksanakan secara online, namun masih terdapat kendala pada bagian sistem yang digunakan saat ini, hal tersebut menyebabkan Politeknik Harapan Bersama tidak dapat melaporkan / mengunggah hasil tracer studi kepada Ditjen Belmawa Ristekdikti, dimana form kuisioner dan data export tracer studi yang dihasilkan berbeda dengan kebutuhan seperti yang tercantum pada surat edaran No. 313/B/SE/2016 tentang pelaksanaan tracer studi di tingkat perguruan tinggi. Mengingat pentingnya tracer studi sebagai umpan balik bagi Politeknik Harapan Bersama, maka perlu solusi untuk mengatasi kekurangan sistem ini. Dengan merubah sistem yang ada dengan sistem tracer studi yang baru merupakan solusi yang tepat dalam permasalahan ini. Sistem tracer studi yang baru mampu menghasilkan data tracer studi alumni dan pengisian form kuisioner sesuai dengan standar Ditjen Belmawa Ristekdikti yang dapat diunggah sistem tracer studi ristekdikti.

  10. IMAGE Project: Results of Laboratory Tests on Tracers for Supercritical Conditions.

    Science.gov (United States)

    Brandvoll, Øyvind; Opsahl Viig, Sissel; Nardini, Isabella; Muller, Jiri

    2016-04-01

    The use of tracers is a well-established technique for monitoring dynamic behaviour of water and gas through a reservoir. In geothermal reservoirs special challenges are encountered due to high temperatures and pressures. In this work, tracer candidates for monitoring water at supercritical conditions (temperature > 374°C, pressure ca 218 bar), are tested in laboratory experiments. Testing of tracers at supercritical water conditions requires experimental set-ups which tolerate harsh conditions with respect to high temperature and pressure. In addition stringent HES (health, environment and safety) factors have to be taken into consideration when designing and performing the experiments. The setup constructed in this project consists of a pressure vessel, high pressure pump, instrumentation for pressure and temperature control and instrumentation required for accurate sampling of tracers. In order to achieve accurate results, a special focus has been paid to the development of the tracer sampling technique. Perfluorinated cyclic hydrocarbons (PFCs) have been selected as tracer candidates. This group of compounds is today commonly used as gas tracers in oil reservoirs. According to the literature they are stable at temperatures up to 400°C. To start with, five PFCs have been tested for thermal stability in static experiments at 375°C and 108 bar in the experimental setup described above. The tracer candidates will be further tested for several months at the relevant conditions. Preliminary results indicate that some of the PFC compounds show stability after three months. However, in order to arrive at conclusive results, the experiments have to be repeated over a longer period and paying special attention to more accurate sampling procedures.

  11. Transport of Perfluorocarbon Tracers in the Cranfield Geological Carbon Sequestration Project

    Science.gov (United States)

    Moortgat, J.; Soltanian, M. R.; Amooie, M. A.; Cole, D. R.; Graham, D. E.; Pfiffner, S. M.; Phelps, T.

    2017-12-01

    A field-scale carbon dioxide (CO2) injection pilot project was conducted by the Southeast Regional Sequestration Partnership (SECARB) at Cranfield, Mississippi. Two associated campaigns in 2009 and 2010 were carried out to co-inject perfluorocarbon tracers (PFTs) and sulfur hexafluoride (SF6) with CO2. Tracers in gas samples from two observation wells were analyzed to construct breakthrough curves. We present the compiled field data as well as detailed numerical modeling of the flow and transport of CO2, brine, and introduced tracers. A high-resolution static model of the formation geology in the Detailed Area Study (DAS) was used in order to capture the impact of connected flow pathways created by fluvial channels on breakthrough curves and breakthrough times of PFTs and SF6 tracers. We use the cubic-plus-association (CPA) equation of state, which takes into account the polar nature of water molecules, to describe the phase behavior of CO2-brine-tracer mixtures. We show how the combination of multiple tracer injection pulses with detailed numerical simulations provide a powerful tool in constraining both formation properties and how complex flow pathways develop over time.

  12. Plutonium as a tracer for soil erosion assessment in northeast China.

    Science.gov (United States)

    Xu, Yihong; Qiao, Jixin; Pan, Shaoming; Hou, Xiaolin; Roos, Per; Cao, Liguo

    2015-04-01

    Soil erosion is one of the most serious environmental and agricultural problems faced by human society. Assessing intensity is an important issue for controlling soil erosion and improving eco-environmental quality. The suitability of the application of plutonium (Pu) as a tracer for soil erosion assessment in northeast China was investigated by comparing with that of 137Cs. Here we build on preliminary work, in which we investigated the potential of Pu as a soil erosion tracer by sampling additional reference sites and potential erosive sites, along the Liaodong Bay region in northeast China, for Pu isotopes and 137Cs. 240Pu/239Pu atomic ratios in all samples were approximately 0.18, which indicated that the dominant source of Pu was the global fallout. Pu showed very similar distribution patterns to those of 137Cs at both uncultivated and cultivated sites. 239+240Pu concentrations in all uncultivated soil cores followed an exponential decline with soil depth, whereas at cultivated sites, Pu was homogenously distributed in plow horizons. Factors such as planted crop types, as well as methods and frequencies of irrigation and tillage were suggested to influence the distribution of radionuclides in cultivated land. The baseline inventories of 239+240Pu and 137Cs were 88.4 and 1688 Bq m(-2) respectively. Soil erosion rates estimated by 239+240Pu tracing method were consistent with those obtained by the 137Cs method, confirming that Pu is an effective tracer with a similar tracing behavior to that of 137Cs for soil erosion assessment. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Nitrate movement and removal along a shallow groundwater flow path in a riparian wetland within a sheep-grazed pastoral catchment : result of a tracer study

    International Nuclear Information System (INIS)

    Burns, D.A.; Nguyen, L.

    2002-01-01

    The movement and removal of nitrate (NO 3 ) along a groundwater flow path within a riparian wetland was investigated during a 24-day period in late autumn-early winter, using a lithium bromide (LiBr)-potassium nitrate (KNO 3 ) tracer solution containing 19 200 mg/litre as Br - and 193.8 mg/litre as NO 3 -N. The tracer solution was added as an instantaneous dose of tracer solution at a depth of 10-20 cm to four injection wells in two 1 m 2 plots within a sheep-grazed pastoral catchment at the Whatawhata Agricultural Research Centre near Hamilton, New Zealand. Bromide and NO 3- N concentrations were measured periodically in: (1) wetland groundwater samples from piezometers installed at 15 and 30 cm depths and located at 30, 60, and 100 cm down gradient from the injection wells; and (2) surface flow samples. Peak concentrations of 50-250 mg/litre of Br - and 0.2-1.1 mg/litre of NO 3 -N were reached within 1-2 days after application at most piezometers. Nitrate concentrations decreased thereafter more sharply than did those of Br - , resulting in decreased NO 3 -N/Br - ratios from Days 2 through 7. More than 99% of groundwater samples collected after the tracer application had NO 3 -N/Br - less than the value in the tracer solution indicating removal of NO 3 -N during transport. Mass flux estimates indicated removal of >90% of added NO 3 -N along the 100 cm flow path from the injection, with essentially all of the NO 3 - removed within the first 30 cm of transport. On Days 10 and 24, just after rain events, surface flow from the experimental plots had greatly elevated NO 3 -N concentrations that were not accompanied by correspondingly elevated Br - concentrations, indicating that NO 3 -N originating from the surrounding catchment was transported over the wetland surface with little penetration or mixing with wetland groundwater. Despite a significant capacity for NO 3 -N removal from shallow groundwater equivalent to an annualised value of 50 kg/ha in these wetland

  14. MAK and BAT values list 2017. Maximum permissible concentrations at the place of work and biological tolerance values for working materials; MAK- und BAT-Werte-Liste 2017. Maximale Arbeitsplatzkonzentrationen und Biologische Arbeitsstofftoleranzwerte

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2017-08-01

    The MAK and BAT values list 2017 includes the maximum permissible concentrations at the place of work and biological tolerance values for working materials. The following working materials are covered: carcinogenic working materials, sensitizing materials and aerosols. The report discusses the restriction of exposure peaks, skin resorption, MAK (maximum working place concentration) values during pregnancy, germ cell mutagens and specific working materials. Importance and application of BAT (biological working material tolerance) values, list of materials, carcinogens, biological guide values and reference values are also included.

  15. Methods and systems using encapsulated tracers and chemicals for reservoir interrogation and manipulation

    Science.gov (United States)

    Roberts, Jeffery; Aines, Roger D; Duoss, Eric B; Spadaccini, Christopher M

    2014-11-04

    An apparatus, method, and system of reservoir interrogation. A tracer is encapsulating in a receptacle. The receptacle containing the tracer is injected into the reservoir. The tracer is analyzed for reservoir interrogation.

  16. On-line measurements of liquid carry-over from scrubbers using radioactive tracers

    Energy Technology Data Exchange (ETDEWEB)

    Haugan, A; Hassfjell, S [Institute for Energy Technology, Kjeller (Norway); Finborud, A [Mator, Porsgrunn (Norway)

    2004-07-01

    A method to measure liquid carry-over from scrubbers using gamma-emitting tracers is described and results from field tests at two onshore installations are presented. One water/1,2-ethanediol (MEG) and two hydrocarbon liquid (condensate) tracers have been used in the tests. One of the condensate tracers deposited to some extent inside the process pipe, while the other had a too high vapor pressure. The water/MEG tracer showed no MEG carry-over while the carry-over of MEG was documented to be considerable. (author)

  17. On-line measurements of liquid carry-over from scrubbers using radioactive tracers

    International Nuclear Information System (INIS)

    Haugan, A.; Hassfjell, S.; Finborud, A.

    2004-01-01

    A method to measure liquid carry-over from scrubbers using gamma-emitting tracers is described and results from field tests at two onshore installations are presented. One water/1,2-ethanediol (MEG) and two hydrocarbon liquid (condensate) tracers have been used in the tests. One of the condensate tracers deposited to some extent inside the process pipe, while the other had a too high vapor pressure. The water/MEG tracer showed no MEG carry-over while the carry-over of MEG was documented to be considerable. (author)

  18. On parameterization of the inverse problem for estimating aquifer properties using tracer data

    International Nuclear Information System (INIS)

    Kowalsky, M. B.; Finsterle, Stefan A.; Williams, Kenneth H.; Murray, Christopher J.; Commer, Michael; Newcomer, Darrell R.; Englert, Andreas L.; Steefel, Carl I.; Hubbard, Susan

    2012-01-01

    We consider a field-scale tracer experiment conducted in 2007 in a shallow uranium-contaminated aquifer at Rifle, Colorado. In developing a reliable approach for inferring hydrological properties at the site through inverse modeling of the tracer data, decisions made on how to parameterize heterogeneity (i.e., how to represent a heterogeneous distribution using a limited number of parameters that are amenable to estimation) are of paramount importance. We present an approach for hydrological inversion of the tracer data and explore, using a 2D synthetic example at first, how parameterization affects the solution, and how additional characterization data could be incorporated to reduce uncertainty. Specifically, we examine sensitivity of the results to the configuration of pilot points used in a geostatistical parameterization, and to the sampling frequency and measurement error of the concentration data. A reliable solution of the inverse problem is found when the pilot point configuration is carefully implemented. In addition, we examine the use of a zonation parameterization, in which the geometry of the geological facies is known (e.g., from geophysical data or core data), to reduce the non-uniqueness of the solution and the number of unknown parameters to be estimated. When zonation information is only available for a limited region, special treatment in the remainder of the model is necessary, such as using a geostatistical parameterization. Finally, inversion of the actual field data is performed using 2D and 3D models, and results are compared with slug test data.

  19. Evaluating Chemical Tracers in Suburban Groundwater as Indicators of Nitrate-Nitrogen Sources

    Science.gov (United States)

    Nitka, A.; DeVita, W. M.; McGinley, P.

    2015-12-01

    The CDC reports that over 15 million US households use private wells. These wells are vulnerable to contamination. One of the most common contaminants in private wells is nitrate. Nitrate has a health standard of 10 mg/L. This standard is set to prevent methemaglobinemia, or "blue baby" syndrome, in infants. In extreme cases it can affect breathing and heart function, and even lead to death. Elevated nitrate concentrations have also been associated with increased risk of thyroid disease, diabetes, and certain types of cancer. Unlike municipal wells, there is no mandatory testing of private wells. It is the responsibility of users to have their well water tested. The objective of this research was to identify the most useful chemical tracers for determining sources of nitrate in private water supplies. Chemical characteristics, such as mobility in groundwater and water solubility, as well as frequency of use, were considered when choosing source indicators. Fourteen pharmaceuticals and personal care products unique to human use were chosen to identify wells impacted by septic waste. A bovine antibiotic and five pesticide metabolites were used to identify contamination from agricultural sources. Eighteen private wells were selected in a suburban area with septic systems and adjacent agricultural land. The wells were sampled five times and analyzed to provide a temporal profile of nitrate and the tracers. The artificial sweetener sucralose was found in >70% of private wells. Wells with sucralose detected had nitrate concentrations between 5-15 mg/L. The herbicide metabolite metolachlor ESA was detected in 50% of the wells. These wells typically had the highest nitrate concentrations, often >10 mg/L. The common use and frequent detection of these two compounds made them the most reliable indicators of nitrate sources evaluated in this study. This information will help well owners determine appropriate treatment and remediation options and could direct future

  20. Use of radioactive tracers in chemical reactions

    International Nuclear Information System (INIS)

    Paci, B.; Saiki, M.

    1979-01-01

    A method for the determination of small quantities of nickel by using radioactive tracers is presented. An analytical application of the displacement reaction between and zinc-ethylenediaminetetraacetate, (Zn-EDTA), labelled with 65 Zn is investigated. This method is based on the extraction of radioactive zinc, displaced by nickel from the zinc chelate, into a dithizone-carbon tetrachloride solution and the subsequent measurement of the activity of an aliquot of the extract. It is shown that the method is very sentitive and nickel can be measured in concentrations as small as 0,1μg/ml or even less, depending on the specific activity of the radioreagent used. The precision and accuracy of the method are determined. An attempt to eliminate the problem of interference by using masking agents or by means of a previous separation of nickel and other interfereing metals, is also made. (Author) [pt

  1. Positron emission tomography tracers for imaging angiogenesis

    International Nuclear Information System (INIS)

    Haubner, Roland; Beer, Ambros J.; Wang, Hui; Chen, Xiaoyuan

    2010-01-01

    Position emission tomography imaging of angiogenesis may provide non-invasive insights into the corresponding molecular processes and may be applied for individualized treatment planning of antiangiogenic therapies. At the moment, most strategies are focusing on the development of radiolabelled proteins and antibody formats targeting VEGF and its receptor or the ED-B domain of a fibronectin isoform as well as radiolabelled matrix metalloproteinase inhibitors or α v β 3 integrin antagonists. Great efforts are being made to develop suitable tracers for different target structures. All of the major strategies focusing on the development of radiolabelled compounds for use with positron emission tomography are summarized in this review. However, because the most intensive work is concentrated on the development of radiolabelled RGD peptides for imaging α v β 3 expression, which has successfully made its way from bench to bedside, these developments are especially emphasized. (orig.)

  2. Flow-rate measurement using radioactive tracers and transit time method

    International Nuclear Information System (INIS)

    Turtiainen, Heikki

    1986-08-01

    The transit time method is a flow measurement method based on tracer techniques. Measurement is done by injecting to the flow a pulse of tracer and measuring its transit time between two detection positions. From the transit time the mean flow velosity and - using the pipe cross section area - the volume flow rate can be calculated. When a radioisotope tracer is used the measurement can be done from outside the pipe and without disturbing the process (excluding the tracer injection). The use of the transit time method has been limited because of difficulties associated with handling and availability of radioactive tracers and lack of equipment suitable for routine use in industrial environments. The purpose of this study was to find out if these difficulties may be overcome by using a portable isotope generator as a tracer source and automating the measurement. In the study a test rig and measuring equipment based on the use of a ''1''3''7Cs/''1''3''7''''mBa isotope generator were constructed. They were used to study the accuracy and error sources of the method and to compare different algorithms to calculate the transit time. The usability of the method and the equipment in industrial environments were studied by carrying out over 20 flow measurements in paper and pulp mills. On the basis of the results of the study, a project for constructing a compact radiatracer flowmeter for industrial use has been started. The application range of this kind of meter is very large. The most obvious applications are in situ calibration of flowmeters, material and energy balance studies, process equipment analyses (e.g. pump efficiency analyses). At the moment tracer techniques are the only methods applicable to these measurements on-line and with sufficient accuracy

  3. Dissolved Vanillin as Tracer for Estuarine Lignin Conversion

    Science.gov (United States)

    Edelkraut, F.

    1996-12-01

    Lignin is produced only by vascular plants and therefore can be used as a tracer for terrestrial organic carbon input to the estuarine and marine environments. Lignin measurements have been done by analyses of the oxidation products such as vanillin or 4-hydroxybenzaldehyde. In the Elbe Estuary, free dissolved vanillin was analysed in order to test whether such measurements yield information on terrestrial carbon inputs into the Estuary and on the vanillin derived from lignin oxidation. In the period 1990-1992, concentrations of dissolved vanillin in the Elbe ranged from 0 to 60 μ g l -1(mean: 8 μg l -1). Higher values were found in areas of increased microbial activity such as the turbidity zone and the river mouth where the water chemistry is influenced by large tidal flats. No correlation was found between dissolved vanillin and suspended matter concentrations, although lignin is normally associated with suspended particulate matter, nor was a covariance seen between dissolved vanillin and the terrestrial carbon inputs into the Estuary. Apparently, biological conversion of lignin was faster than the transport processes, and local sources were more dominant for the vanillin concentration than riverine sources. The dissolved vanillin turnover was fast and, consequently, a significant amount of lignin may be converted within an estuary. In sediments from the Estuary, the concentrations of dissolved vanillin were similar to those found in the water phase and showed no clear vertical profile. The sediment is unlikely to be the source for vanillin.

  4. Purification of tracer for somatomedin C radioimmunoassay by hydrophobic interaction chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Baxter, R.C.; Brown, A.S.

    1982-03-01

    A tracer for use in the somatomedin C radiommunoassay by hydrophobic interaction chromatography was purified. Material showing greatest immunoreactivity binds to Octyl Sepharose CL-4B (Pharmacia) in a buffer mixture consisting of 130 mL of acetonitrile and 870 mL of 0.1 mol/L NH/sub 4/HCO/sub 3/, pH 7.8, but is eluted by increasing the acetonitrile content to 180 mL/L. As compared with tracer purified by binding to specific antiserum in liquid phase, precipitating the complex with second antibody, and then dissociating by gel chromatography at acid pH, this tracer shows equal immunoreactivity against specific somatomedin C antiserum. Either preparation allows excellent discrimination between extracts of normal, acromegalic, and hypopituitary plasma samples; thus either is suitable for use in the somatomedin C radioimmunoassay. Tracer purification by hydrophobic interaction chromatography is rapid and inexpensive. It may be useful in preparing highly immunoreactive tracers for other peptide radioimmunoassays.

  5. Spectral analysis for evaluation of myocardial tracers for medical imaging

    International Nuclear Information System (INIS)

    Huesman, Ronald H.; Reutter, Bryan W.; Marshall, Robert C.

    2000-01-01

    Kinetic analysis of dynamic tracer data is performed with the goal of evaluating myocardial radiotracers for cardiac nuclear medicine imaging. Data from experiments utilizing the isolated rabbit heart model are acquired by sampling the venous blood after introduction of a tracer of interest and a reference tracer. We have taken the approach that the kinetics are properly characterized by an impulse response function which describes the difference between the reference molecule (which does not leave the vasculature) and the molecule of interest which is transported across the capillary boundary and is made available to the cell. Using this formalism we can model the appearance of the tracer of interest in the venous output of the heart as a convolution of the appearance of the reference tracer with the impulse response. In this work we parameterize the impulse response function as the sum of a large number of exponential functions whose predetermined decay constants form a spectrum, and each is required only to have a nonnegative coefficient. This approach, called spectral analysis, has the advantage that it allows conventional compartmental analysis without prior knowledge of the number of compartments which the physiology may require or which the data will support

  6. Deciphering relationships between in-stream travel times, nutrient concentrations, and uptake through analysis of hysteretic and non-hysteretic kinetic behavior

    Science.gov (United States)

    Covino, T. P.; Bowden, W. B.; Gooseff, M. N.; Wollheim, W. M.; McGlynn, B. L.; Whittinghill, K. A.; Wlostowski, A. N.; Herstand, M. R.

    2012-12-01

    Understanding the relationship between solute travel time, concentration, and nutrient uptake remains a central question in watershed hydrology and biogeochemistry. Theoretical understanding predicts that nutrient uptake should increase as in-stream solute travel time lengthens and/or as concentration increases; however, results from field-based studies have been contradictory. We used a newly developed approach, Tracer Additions for Spiraling Curve Characterization (TASCC), to investigate relationships between solute travel time, nutrient concentration, and nutrient uptake across a range of stream types. This approach allows us to quantify in-stream nutrient uptake across a range of travel times and nutrient concentrations using single instantaneous injections (slugs) of conservative and non-conservative tracers. In some systems we observed counter-clockwise hysteresis loops in the relationship between nutrient uptake and concentration. Greater nutrient uptake on the falling limb of tracer breakthrough curves indicates stronger uptake for a given concentration at longer travel times. However, in other systems we did not observe hysteresis in these relationships. Lack of hysteresis indicates that nutrient uptake kinetics were not influenced by travel time travel time. Here we investigate the potential roles of travel time and in-stream flowpaths that could be responsible for hysteretic behavior.

  7. Spatiotemporal modeling of PM2.5 concentrations at the national scale combining land use regression and Bayesian maximum entropy in China.

    Science.gov (United States)

    Chen, Li; Gao, Shuang; Zhang, Hui; Sun, Yanling; Ma, Zhenxing; Vedal, Sverre; Mao, Jian; Bai, Zhipeng

    2018-05-03

    Concentrations of particulate matter with aerodynamic diameter Bayesian Maximum Entropy (BME) interpolation of the LUR space-time residuals were developed to estimate the PM 2.5 concentrations on a national scale in China. This hybrid model could potentially provide more valid predictions than a commonly-used LUR model. The LUR/BME model had good performance characteristics, with R 2  = 0.82 and root mean square error (RMSE) of 4.6 μg/m 3 . Prediction errors of the LUR/BME model were reduced by incorporating soft data accounting for data uncertainty, with the R 2 increasing by 6%. The performance of LUR/BME is better than OK/BME. The LUR/BME model is the most accurate fine spatial scale PM 2.5 model developed to date for China. Copyright © 2018. Published by Elsevier Ltd.

  8. Transfer function analysis of positron-emitting tracer imaging system (PETIS) data

    International Nuclear Information System (INIS)

    Keutgen, N.; Matsuhashi, S.; Mizuniwa, C.; Ito, T.; Fujimura, T.; Ishioka, N.S.; Watanabe, S.; Sekine, T.; Uchida, H.; Hashimoto, S.

    2002-01-01

    Quantitative analysis of the two-dimensional image data obtained with the positron-emitting tracer imaging system (PETIS) for plant physiology has been carried out using a transfer function analysis method. While a cut leaf base of Chinese chive (Allium tuberosum Rottler) or a cut stem of soybean (Glycine max L.) was immersed in an aqueous solution containing the [ 18 F] F - ion or [ 13 N]NO 3 - ion, tracer images of the leaf of Chinese chive and the trifoliate of soybean were recorded with PETIS. From the time sequence of images, the tracer transfer function was estimated from which the speed of tracer transport and the fraction moved between specified image positions were deduced

  9. Study on bioavailability of zinc for children's diet by using activable isotopic tracer 70Zn and neutron activation analysis techniques

    International Nuclear Information System (INIS)

    Zhang Yangmei; Ni Bangfa; Wang Pingsheng; Tian Weizhi; Cao Lei

    2001-01-01

    Bioavailability of zinc for three groups (low amount of diet zinc, balance amount of diet zinc and high amount of diet zinc) of children's diet is studied by using activable isotopic tracer 70 Zn and neutron activation analysis techniques. The results indicate that the fractional absorption of zinc from balance diet zinc group is the highest, up to 33.9%. A procedure of pre-irradiation concentration zinc for fecal samples using anion exchanger is developed, and the enriched 70 Zn with isotopic abundance of 18.3% is used for tracer. The mass ratios between 70 Zn and 68 Zn or 64 Zn and their contents between natural zinc and enriched zinc are used to calculate the bioavailability of zinc. Instrumental neutron activation analysis of 64 Zn of each original fecal samples and pre-irradiation concentrated zinc samples are used to normalize the chemical yield in order to reduce the uncertainty during the chemical separation procedure

  10. ATTILA - Atmospheric Tracer Transport In a Langrangian Model

    Energy Technology Data Exchange (ETDEWEB)

    Reithmeier, C.; Sausen, R.

    2000-07-01

    The Lagrangian model ATTILA (atmospheric tracer transport in a Lagrangian model) has been developed to treat the global-scale transport of passive trace species in the atmosphere within the framework of a general circulation model (GCM). ATTILA runs online within the GCM ECHAM4 and uses the GCM produced wind field to advect the centrois of 80.000 to 180.000 constant mass air parcels into which the model atmosphere is divided. Each trace constituent is thereby represented by a mass mixing ratio in each parcel. ATTILA contains state-of-the-art parameterizations of convection, turbulent boundary layer mixing, and interparcel transport and provides an algorithm to map the tracer concentrations from the trajectories to the ECHAM model grid. We use two experiments to evaluate the transport characteristics of ATTILA against observations and the standard semiLagrangian transport scheme of ECHAM. In the first experiment we simulate the distribution of the short-lived tracer Radon ({sup 222}Rn) in order to examine fast vertical transport over continents, and long-range transport from the continents to remote areas. In the second experiment, we simulate the distribution of radiocarbon ({sup 14}C) that was injected into the northern stratosphere during the nuclear weapon tests in the early 60ties, in order to examine upper tropospheric and stratospheric transport characteristics. ATTILA compares well to the observations and in many respects to the semiLagrangian scheme. However, contrary to the semiLagrangian scheme, ATTILA shows a greatly reduced meridional transport in the upper troposphere and lower stratosphere, and a reduced downward flux from the stratosphere to the troposphere, especially in midlatitudes. Since both transport schemes use the same model meteorology, we conclude that the often cited enhanced meridional transport and overestimated downward flux in ECHAM as described above is rather due to the numerical properties of the semiLagrangian scheme than due to an

  11. Study of solid and liquid behavior in large copper flotation cells (130 m2) using radioactive tracers

    International Nuclear Information System (INIS)

    Diaz, F.; Jimenez, O.; Yianatos, J.; Contreras, F.

    2013-01-01

    The behavior of the solid and liquid phases, in large flotation cells, was characterized by means of the radioactive tracer technique. The use of radioactive tracers enabled the identification of the Residence Time Distribution, of floatable and non-floatable solid, from continuous (on-line) measuring at the output streams of the flotation cells. For this study, the proper radioactive tracers were selected and applied in order to characterize the different phases; i.e. for liquid phase Br-82 as Ammonium Bromide, for floatable solid recovered in the concentrate Cu-64, and for non-floatable solid in three particle size classes (coarse: >150 μm, intermediate: 45 μm, and fine: <45 μm), Na-24. The experimental results confirmed the strong effect of particle size on the Residence Time Distribution, and mean residence time of solids in larger flotation cells, and consequently in flotation hydrodynamics. From a hydrodynamic point of view, the experimental data confirmed that a single mechanical flotation cells, of large size, can deviate significantly from perfect mixing. The experimental work was developed in a 130 m3 industrial flotation cell of the rougher circuit at El Teniente Division, Codelco-Chile. (authors)

  12. Statistical dynamic imaging of RI-labeled tracer from list-mode PET data

    International Nuclear Information System (INIS)

    Tanimoto, Michiaki; Kuroda, Yoshihiro; Oshiro, Osamu; Watabe, Hiroshi; Kuroda, Tomohiro

    2009-01-01

    Positron emission tomography (PET) can be used in physiological analysis to illustrate physiological states by visualizing the accumulation of radioisotope (RI)-labeled tracer in specific organs or tissues. PET obtains spatio-temporal statistics in the form of list-mode data. However, conventional imaging techniques, which sum up list-mode data over a given time period, cannot depict detailed temporal dynamics of the RI-labeled tracer. In this study, a spatio-temporal analysis approach was employed to visualize the temporal flow dynamics of RI-labeled tracer from the obtained list-mode data. Experiments to assess the visualization of simulated RI-labeled tracer dynamics as well as RI-labeled tracer dynamics in a vascular phantom showed that the proposed method successfully depicted detailed temporal flow dynamics that could not be visualized using conventional methods. (author)

  13. Use of radon-222 as tracer to estimate groundwater infiltration velocity in a river bank area

    International Nuclear Information System (INIS)

    Trinh Van Giap

    2003-01-01

    Naturally occurring isotope Rn-222 has been used as a natural tracer to determine the residence time of groundwater infiltrated from river into an aquifer in a riverbank area. The applied method is based on the increasing radon concentration in infiltrating water during it passes through the riverbank and reaches an equilibrium value. Solid-state nuclear track detector technique is used to measure directly radon concentration in water of a well. In order to confirm the relationship between radon concentration and it's residence time, a model was constructed in the laboratory. Experiment carried out in Nam Dinh are showed that mean infiltrating velocity of groundwater in the studied area as high as 5.1 m/day. (author)

  14. Characterization of eco-friendly fluorescent nanoparticle-doped tracers for environmental sensing

    International Nuclear Information System (INIS)

    Tauro, Flavia; Rapiti, Emiliano; Al-Sharab, Jafar F.; Ubertini, Lucio; Grimaldi, Salvatore; Porfiri, Maurizio

    2013-01-01

    Particle tracers are extensively used in quantitative flow visualization and environmental sensing. In this paper, we provide a thorough characterization of the novel eco-friendly fluorescent particle tracers formulated in Tauro et al. (AIP Adv 3(3): 032108, 2013). The tracers are synthesized from natural beeswax and are functionalized by encapsulating nontoxic fluorophore nanoparticles in the beads’ matrix through an inexpensive thermal procedure. Visibility and durability studies are conducted through a wide array of techniques to investigate the tracers’ surface morphological microfeatures, crystal nature and size, chemical composition, fluorophore incorporation into the beeswax matrix, and fluorescence response under severe settings resembling exposure to natural environments. Our findings demonstrate that fluorescent nanoparticles ranging from 1.51 to 3.73 nm are homogeneously distributed in the superficial layer (12 nm) of the tracers. In addition, fluorescence emissions are observed up to 26 days of continuous exposure of the tracers to high energy radiation. To demonstrate the particles’ use in environmental flow sensing, a set of proof of concept outdoor tests are conducted, in which image analysis tools are utilized for detecting the fluorescent tracers. Experimental results suggest that fluorescent microparticles deployed in high flow-rate flows (2 m/s) and under direct sunlight can be sensed through commercially available cameras (frame rate set to 30 Hz)

  15. Excavation damage zone tracer experiment in the floor of the room 415 test tunnel

    International Nuclear Information System (INIS)

    Frost, L.H.; Everitt, R.A.

    1997-03-01

    A 3.5-m-diameter test tunnel was constructed on the 420 Level of AECL's Underground Research Laboratory using a mechanical excavation technique. The orientation of the tunnel was chosen to maximize the stress ratio in the plane perpendicular to the tunnel axis in order to promote and study stress-induced excavation damage. The resulting excavation damage zone (EDZ) is characterized by a distinct breakout notch in both the floor and roof of the tunnel. In the floor of the tunnel, the main flow pathway within the EDZ is within a zone of intense grain-size fracturing (process zone) located at the tip of the breakout notch; virtually no flow occurs outside this region. A tracer experiment was performed within the EDZ in the floor of the tunnel to characterize the solute transport properties (permeability, transport porosity and dispersivity) within the process zone, as well as to develop and demonstrate methods for determining the transport properties within EDZs of underground tunnels. The experiment was performed as a constant head test by continuously injecting a constant concentration of iodide tracer into a region of the process zone, and by monitoring tracer breakthrough from the zone at a distance 1.5 m away. An equivalent-porous-media approach was taken in analysing fluid flow and solute transport through the process zone. Based on mass flux calculations, the hydraulic conductivity and transport porosity of the process zone are estimated to be 7.4 x 10 -7 m/s and 2.7 % respectively. Based on an analytic solution that represents tracer transport within the process zone as one-dimensional advective diffusive transport in a finite homogeneous porous medium, the longitudinal dispersivity and transport porosity of the zone are estimated to be 0.60 m and 3.3 % respectively. The transport porosity values estimated by both the mass flux and analytic calculations compare quite well. (author)

  16. Bayesian Nitrate Source Apportionment to Individual Groundwater Wells in the Central Valley by use of Nitrogen, Oxygen, and Boron Isotopic Tracers

    Science.gov (United States)

    Lockhart, K.; Harter, T.; Grote, M.; Young, M. B.; Eppich, G.; Deinhart, A.; Wimpenny, J.; Yin, Q. Z.

    2014-12-01

    Groundwater quality is a concern in alluvial aquifers underlying agricultural areas worldwide, an example of which is the San Joaquin Valley, California. Nitrate from land applied fertilizers or from animal waste can leach to groundwater and contaminate drinking water resources. Dairy manure and synthetic fertilizers are the major sources of nitrate in groundwater in the San Joaquin Valley, however, septic waste can be a major source in some areas. As in other such regions around the world, the rural population in the San Joaquin Valley relies almost exclusively on shallow domestic wells (≤150 m deep), of which many have been affected by nitrate. Consumption of water containing nitrate above the drinking water limit has been linked to major health effects including low blood oxygen in infants and certain cancers. Knowledge of the proportion of each of the three main nitrate sources (manure, synthetic fertilizer, and septic waste) contributing to individual well nitrate can aid future regulatory decisions. Nitrogen, oxygen, and boron isotopes can be used as tracers to differentiate between the three main nitrate sources. Mixing models quantify the proportional contributions of sources to a mixture by using the concentration of conservative tracers within each source as a source signature. Deterministic mixing models are common, but do not allow for variability in the tracer source concentration or overlap of tracer concentrations between sources. Bayesian statistics used in conjunction with mixing models can incorporate variability in the source signature. We developed a Bayesian mixing model on a pilot network of 32 private domestic wells in the San Joaquin Valley for which nitrate as well as nitrogen, oxygen, and boron isotopes were measured. Probability distributions for nitrogen, oxygen, and boron isotope source signatures for manure, fertilizer, and septic waste were compiled from the literature and from a previous groundwater monitoring project on several

  17. Natural stream flow-rates measurements by tracer techniques

    International Nuclear Information System (INIS)

    Cuellar Mansilla, J.

    1982-01-01

    This paper presents the study of the precision obtained measuring the natural stream flow rates by tracer techniques, especially when the system presents a great slope and a bed constituted by large and extended particle size. The experiences were realized in laboratory pilot channels with flow-rates between 15 and 130 [1/s]; and in natural streams with flow-rates from 1 to 25 m 3 /s. Tracer used were In-133m and Br-82 for laboratory and field measurements respectively. In both cases the tracer was injected as a pulse and its dilution measured collecting samples in the measured section, at constant flow-rates, of 5[1] in laboratory experiences and 60[1] of water in field experiences. Precisions obtained at a 95% confidence level were about 2% for laboratory and 3% for field. (I.V.)

  18. Identification and characterization of conservative organic tracers for use as hydrologic tracers for the Yucca Mountain site characterization project: Quality Assurance Project Plan, Revision 1

    International Nuclear Information System (INIS)

    Stetzenbach, K.J.

    1993-01-01

    The purpose of this work is to identify and characterize candidate conservative organic tracers for use as hydrologic tracers for experiments to be conducted at the Yucca Mountain C-well complex. During this quarter the main effort was directed towards rewriting the quality assurance program in preparation for a review and audit by the USGS. However, due to budget constraints the review and audit were not carried out. The tracer QA plan and standard operating procedures (SOPs) were revised and copies are included in the report. Instrumental problems were encountered and corrected with the addition of new integration and sample control software. In the sampling, there was an unexplained peak in the chromatograms of the tracers being tested in the light tuff. This was not correctable and these experiments will be repeated in the next quarter

  19. An experimental approach to determining subsurface leakage from a surface impoundment using a radioisotope tracer

    International Nuclear Information System (INIS)

    Ashwood, T.L.; Story, J.D.; Larsen, I.L.; Schultz, F.J.

    1987-01-01

    Bromine-82, a 35.3-h half-life radionuclide, was used as a tracer to determine the paths and rates of leakage from an unlined, 1,000,000-gal (3,785,000 L), surface impoundment at the Oak Ridge National Laboratory. Since the impoundment is underlain and surrounded by storm sewer and sanitary sewer lines (most of them predating the impoundment), known and suspected leak sites in storm drain catch basins and sanitary sewer manholes were sampled periodically and analyzed for 82 Br. A series of four ground water monitoring wells - three downgradient and one upgradient from the impoundment - were also sampled for 82 Br. Although the catch basin and manhole samples picked up 82 Br in leakage from the impoundment less than 5 h after application of the tracer, the monitoring well samples did not contain detectable levels of the radionuclide. It was concluded that the monitoring wells were sampling groundwater moving through the formation, whereas the storm drains and manholes were sampling water leading rapidly through secondary porosity and along preferred pathways. The decline in tracer concentration as a function of time was used to determine the residence time of water in the pond and hence the flow rate through the pond. This flow rate, when compared with the known outflow rate, indicated that the leakage flow was small. Hence, the main value of the test was to identify rapid leakage pathways. The experiment demonstrates the need for sampling subsurface drain systems as part of an integrated monitoring system for leak detection. The effectiveness of 82 Br as a tracer for rapid leaks was also shown

  20. Monitoring of water movement in paddy field's soil using a bromide tracer

    International Nuclear Information System (INIS)

    Asiah Ahmad; Kouichi Yuita

    1994-01-01

    Water movement in soils at the lower course and the middle course of Sakawa River's paddy field was monitored over an 8 week period using a bromide tracer. The water of soil samples taken one day after bromide application contained high concentrations of bromide at 50 to 60 cm soil depth at lower course. The bromide was concentrated promarily within 20 to 80 cm depth. No downward movement below 80 cm depth was detected six weeks afetr the application. This might indicate the high water table of this area. On the other hand, bromide concentrations were high at 50 cm depth in water of the soils sample taken one day after application from the middle course of Sakawa River plot. However, the concentrations were nearly at background level in all samples taken from the middle course of sakawa River 3 weeks after application. The evidence from bromide's movement shows that water readily penetrate the soils at the middle course of Sakawa River. The downward movement was faster compared to that at lower course

  1. Hydraulic contacts identification in the aquifers of limestone ridges: tracer tests in the Montelago pilot area (Central Apennines

    Directory of Open Access Journals (Sweden)

    Alberto Tazioli

    2016-08-01

    Full Text Available The investigated area, located in the inner part of the Marche region (central Italy and belonging to the carbonate Umbria- Marche ridges in the central Apennines, is characterised by very complex geo-structural setting and widespread karst phenomena that make difficult the definition of the relation among the aquifers basing only on the hydrogeological survey. Hence, the presence of different flowpaths among aquifers of the Umbria-Marche hydrostratigraphic sequence and of tectonic contacts among the different structures is verified using tracer tests. In particular, the tests showed that the Calcare Massiccio and the Maiolica aquifers are connected under certain tectonic conditions. A new tracer given by a single stranded DNA molecule and traditional fluorescent dyes have been injected into the Montelago sinkhole in different periods (during the recharge and during the discharge and recovered in several points along the expected hydrogeological basin, using either manual and automatic sampling. Fluorescent traps were positioned in creeks, rivers and springs. The DNA molecule is useful to trace surface water and groundwater, is detectable even at very low concentrations, no significant change in water density and viscosity can be observed and its use is not dangerous for the environment. The results stress the suitability of DNA as hydrogeological tracer, capable to identify connections among aquifers and study different flowpaths even in high flow conditions when traditional tracers are more and more diluted. Moreover, fluorescein tracer allowed for the transport parameter determination, giving mean velocities ranging from 100 to 3000 m/day and mean residence time from some tens to hundreds of hours, and determining the aquifer volumes.

  2. Area-under-the-curve monitoring of cyclosporine therapy: Performance of different assay methods and their target concentrations

    International Nuclear Information System (INIS)

    Grevel, J.; Napoli, K.L.; Gibbons, S.; Kahan, B.D.

    1990-01-01

    The measurement of areas under the concentration-time curve (AUC) was recently introduced as an alternative to trough level monitoring of cyclosporine therapy. The AUC is divided by the oral dosing interval to calculate an average concentration. All measurements are performed at clinical steady state. The initial evaluation of AUC monitoring showed advantages over trough level monitoring with concentrations of cyclosporine measured in serum by the polyclonal radioimmunoassay of Sandoz. This assay technique is no longer available and the following assays were performed in parallel during up to 173 AUC determinations in 51 consecutive renal transplant patients: polyclonal fluorescence polarization immunoassay of Abbott in serum, specific and nonspecific monoclonal radioimmunoassays using 3 H and 125 I tracers in serum and whole blood, and high performance liquid chromatography in whole blood. Both trough levels and average concentrations at steady state measured by those different techniques were significantly correlated with the oral dose. The best correlation (r2 = 0.54) was shown by average concentrations measured in whole blood by the specific monoclonal radioimmunoassay of Sandoz ( 3 H tracer). This monitoring technique was also associated with the smallest absolute error between repeated observations in the same patient while the oral dose rate remained the same or was changed. Both allegedly specific monoclonal radioimmunoassays (with 3 H and 125 I tracer) measured significantly higher concentrations than the liquid chromatography

  3. Simultaneous measurement of local particle movement, solids concentrations and bubble properties in fluidized bed reactors using a novel fiber optical technique

    Energy Technology Data Exchange (ETDEWEB)

    Tayebi, Davoud

    1999-12-31

    This thesis develops a new method for simultaneous measurements of local flow properties in highly concentrated multiphase flow systems such as gas-solid fluidized bed reactors. The method is based on fiber optical technique and tracer particles. A particle present in the measuring volume in front of the probe is marked with a fluorescent dye. A light source illuminates the particles and the detecting fibres receive reflected light from uncoated particles and fluorescent light from the tracer particle. Using optical filters, the fluorescent light can be distinguished and together with a small fraction of background light from uncoated particles can be used for determination of local flow properties. Using this method, one can simultaneously measure the local movement of a single tracer particle, local bubble properties and the local solids volume fractions in different positions in the bed. The method is independent of the physical properties of the tracer particles. It is also independent of the local solids concentrations in the range of 0 to 60 vol.-%, but is mainly designed for highly concentrated flow systems. A computer programme that uses good signals from at least three sensors simultaneously to calculate the tracer particle velocity in two dimensions have been developed. It also calculates the bubble properties and local solids volume fractions from the same time series. 251 refs., 150 figs., 5 tabs.

  4. Simultaneous measurement of local particle movement, solids concentrations and bubble properties in fluidized bed reactors using a novel fiber optical technique

    Energy Technology Data Exchange (ETDEWEB)

    Tayebi, Davoud

    1998-12-31

    This thesis develops a new method for simultaneous measurements of local flow properties in highly concentrated multiphase flow systems such as gas-solid fluidized bed reactors. The method is based on fiber optical technique and tracer particles. A particle present in the measuring volume in front of the probe is marked with a fluorescent dye. A light source illuminates the particles and the detecting fibres receive reflected light from uncoated particles and fluorescent light from the tracer particle. Using optical filters, the fluorescent light can be distinguished and together with a small fraction of background light from uncoated particles can be used for determination of local flow properties. Using this method, one can simultaneously measure the local movement of a single tracer particle, local bubble properties and the local solids volume fractions in different positions in the bed. The method is independent of the physical properties of the tracer particles. It is also independent of the local solids concentrations in the range of 0 to 60 vol.-%, but is mainly designed for highly concentrated flow systems. A computer programme that uses good signals from at least three sensors simultaneously to calculate the tracer particle velocity in two dimensions have been developed. It also calculates the bubble properties and local solids volume fractions from the same time series. 251 refs., 150 figs., 5 tabs.

  5. Tracer technology modeling the flow of fluids

    CERN Document Server

    Levenspiel, Octave

    2012-01-01

    A vessel’s behavior as a heat exchanger, absorber, reactor, or other process unit is dependent upon how fluid flows through the vessel.  In early engineering, the designer would assume either plug flow or mixed flow of the fluid through the vessel.  However, these assumptions were oftentimes inaccurate, sometimes being off by a volume factor of 100 or more.  The result of this unreliable figure produced ineffective products in multiple reaction systems.   Written by a pioneering researcher in the field of chemical engineering, the tracer method was introduced to provide more accurate flow data.  First, the tracer method measured the actual flow of fluid through a vessel.  Second, it developed a suitable model to represent the flow in question.  Such models are used to follow the flow of fluid in chemical reactors and other process units, like in rivers and streams, or solid and porous structures.  In medicine, the tracer method is used to study the flow of chemicals—harmful  and harmless—in the...

  6. Commercial applications of perfluorocarbon tracer (PFT) technology

    International Nuclear Information System (INIS)

    Dietz, R.N.

    1991-06-01

    Tracer technology can be successfully applied to many leak-checking and monitoring evaluations of operating systems (e.g., building HVACs), manufacturing processes and products (e.g., air conditioners), and subsurface components and systems (e.g., underground storage tanks). Perfluorocarbon tracer (PFT) technology is the most sensitive of all tracer technologies because the ambient background levels of the five (5) routinely-used PFTs are in the range of parts per 10 15 parts of air (i.e., parts per quadrillion-ppq) and this technology's instrumentation can measure down to those levels. The effectiveness of this technology is achieved both in terms of cost (very little PFT need to be used) and detectability; for example, very small leaks can be rapidly detected. The PFT compounds, which are environmentally and biologically safe to use, are commercially available as are the sampling and analysis instrumentation. This presentation concerns (1) the steps being taken to commercialize this technology, (2) new applications of processes currently under study, and (3) applications in areas of use that will be particularly beneficial to the environment. 21 refs., 2 figs., 2 tabs

  7. Study on lead transportation in air-water-paddy system with 210Pb as tracer

    International Nuclear Information System (INIS)

    Li Shuding; Zhang Hairong; Ma Xuejun

    1987-08-01

    With 210 PbCl 2 as tracer, a research into lead sources in brown rice, lead distribution in soil and rice, lead chemical forms in soil and their change with time, availability of soil for rice and effect of soil pH on the Pb adsorption was carried out in air-water-paddy system near cities and towns located upper and middle reaches of Liaohe River, northeastern China. Test soil was light acid meadow brown soil. The Pb proportions in rice grain derived from the soil, airborne dust and irrigation water and the transportation pathway to brown rice were investigated. Transportation coefficients of Pb in the system were determined by tracer experiment. It was indicated that the Pb concentration in rice root, the Pb concentration and its distribution in the soil are main factors effecting Pb transportation to rice. Based on the simulation test, mathematical model for computing soil environmental capacity of Pb in the system is put forward. The soil environmental capacity of Pb computed is 1600 - 1700 ppm, i.e. 3.6 - 3.8 t/ha. The computed result was in agreement with the observed. The mathematical model was also used to compute soil enviromental capacity of those heavy metal corresponding respectively with 203 Hg, 115+115m Cd, 65 Zn, 51 Cr, 65 Ni, 60 Co etc

  8. Heterologous radioimmunoassay for llama and alpaca luteinizing hormone with a monoclonal antibody, and equine standard and a human tracer

    International Nuclear Information System (INIS)

    Aba, M.A.; Forsberg, M.

    1995-01-01

    A radioimmunoassay for llama and alpaca LH was developed using a human I 125 LH tracer from a commercial kit, equine LH diluted in human LH free serum as standard, and amonoclonal antibody (518B7) specific for LH but with low species specificity. A 60-min delay in the addition of the tracer and overnight incubation gave a sensitivity of 0.8 μ3g L -1 . The intra-assay coefficient of variation was 37% at 1 μg L -1 , declined to 15% at 4 μg L -1 and was below 6% for concentrations up to 32 μg L -1 . The inter-assay coefficients of variation for 3 control samples were 20% (2.8 μg L -1 ), 16% (7.1 μg L -1 ) and 9.8% (19 μg L -1 ). In an attempt to increase sensitivity, all tubes were preincubated for 4 h at room temperature before adding the tracer, and the sample volume was increased from 50 μL to 100 μL (in the standard curve the increased volume was compensated for by human LH free serum). With this protocol, the assay sensitivity was 0,5 μg L -1 . The assay was validated clinically and demonstrated increased concentrations of LH after mating in llamas and alpacas. Furthermore, the assay was used to monitor LH responses to a single dose of GnRH in llamas (adult males and females at different ages). (au) 9 refs

  9. Selection of suitable mineral acid and its concentration for biphasic dilute acid hydrolysis of the sodium dithionite delignified Prosopis juliflora to hydrolyze maximum holocellulose.

    Science.gov (United States)

    Naseeruddin, Shaik; Desai, Suseelendra; Venkateswar Rao, L

    2016-02-01

    Two grams of delignified substrate at 10% (w/v) level was subjected to biphasic dilute acid hydrolysis using phosphoric acid, hydrochloric acid and sulfuric acid separately at 110 °C for 10 min in phase-I and 121 °C for 15 min in phase-II. Combinations of acid concentrations in two phases were varied for maximum holocellulose hydrolysis with release of fewer inhibitors, to select the suitable acid and its concentration. Among three acids, sulfuric acid in combination of 1 & 2% (v/v) hydrolyzed maximum holocellulose of 25.44±0.44% releasing 0.51±0.02 g/L of phenolics and 0.12±0.002 g/L of furans, respectively. Further, hydrolysis of delignified substrate using selected acid by varying reaction time and temperature hydrolyzed 55.58±1.78% of holocellulose releasing 2.11±0.07 g/L and 1.37±0.03 g/L of phenolics and furans, respectively at conditions of 110 °C for 45 min in phase-I & 121 °C for 60 min in phase-II. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Single-well tracer methods for hydrogeologic evaluation of target aquifers

    International Nuclear Information System (INIS)

    Hall, S.H.

    1994-11-01

    Designing an efficient well field for an aquifer thermal energy storage (ATES) project requires measuring local groundwater flow parameters as well as estimating horizontal and vertical inhomogeneity. Effective porosity determines the volume of aquifer needed to store a given volume of heated or chilled water. Ground-water flow velocity governs the migration of the thermal plume, and dispersion and heat exchange along the flow path reduces the thermal intensity of the recovered plume. Stratigraphic variations in the aquifer will affect plume dispersion, may bias the apparent rate of migration of the plume, and can prevent efficient hydraulic communication between wells. Single-well tracer methods using a conservative flow tracer such as bromide, along with pumping tests and water-level measurements, provide a rapid and cost-effective means for estimating flow parameters. A drift-and-pumpback tracer test yields effective porosity and flow velocity. Point-dilution tracer testing, using new instrumentation for downhole tracer measurement and a new method for calibrating the point-dilution test itself, yields depth-discrete hydraulic conductivity as it is affected by stratigraphy, and can be used to estimate well transmissivity. Experience in conducting both drift-and-pumpback and point-dilution tests at three different test sites has yielded important information that highlights both the power and the limitations of the single-well tracer methods. These sites are the University of Alabama Student Recreation Center (UASRC) ATES well field and the VA Medical Center (VA) ATES well field, both located in Tuscaloosa, Alabama, and the Hanford bioremediation test site north of Richland, Washington

  11. Relative distance between tracers as a measure of diffusivity within moving aggregates

    Science.gov (United States)

    Pönisch, Wolfram; Zaburdaev, Vasily

    2018-02-01

    Tracking of particles, be it a passive tracer or an actively moving bacterium in the growing bacterial colony, is a powerful technique to probe the physical properties of the environment of the particles. One of the most common measures of particle motion driven by fluctuations and random forces is its diffusivity, which is routinely obtained by measuring the mean squared displacement of the particles. However, often the tracer particles may be moving in a domain or an aggregate which itself experiences some regular or random motion and thus masks the diffusivity of tracers. Here we provide a method for assessing the diffusivity of tracer particles within mobile aggregates by measuring the so-called mean squared relative distance (MSRD) between two tracers. We provide analytical expressions for both the ensemble and time averaged MSRD allowing for direct identification of diffusivities from experimental data.

  12. Calculating tracer currents through narrow ion channels: Beyond the independent particle model.

    Science.gov (United States)

    Coalson, Rob D; Jasnow, David

    2018-06-01

    Discrete state models of single-file ion permeation through a narrow ion channel pore are employed to analyze the ratio of forward to backward tracer current. Conditions under which the well-known Ussing formula for this ratio hold are explored in systems where ions do not move independently through the channel. Building detailed balance into the rate constants for the model in such a way that under equilibrium conditions (equal rate of forward vs. backward permeation events) the Nernst Equation is satisfied, it is found that in a model where only one ion can occupy the channel at a time, the Ussing formula is always obeyed for any number of binding sites, reservoir concentrations of the ions and electric potential difference across the membrane which the ion channel spans, independent of the internal details of the permeation pathway. However, numerical analysis demonstrates that when multiple ions can occupy the channel at once, the nonequilibrium forward/backward tracer flux ratio deviates from the prediction of the Ussing model. Assuming an appropriate effective potential experienced by ions in the channel, we provide explicit formulae for the rate constants in these models. © 2018 IOP Publishing Ltd.

  13. Complex functionality with minimal computation: Promise and pitfalls of reduced-tracer ocean biogeochemistry models

    Science.gov (United States)

    Galbraith, Eric D.; Dunne, John P.; Gnanadesikan, Anand; Slater, Richard D.; Sarmiento, Jorge L.; Dufour, Carolina O.; de Souza, Gregory F.; Bianchi, Daniele; Claret, Mariona; Rodgers, Keith B.; Marvasti, Seyedehsafoura Sedigh

    2015-12-01

    Earth System Models increasingly include ocean biogeochemistry models in order to predict changes in ocean carbon storage, hypoxia, and biological productivity under climate change. However, state-of-the-art ocean biogeochemical models include many advected tracers, that significantly increase the computational resources required, forcing a trade-off with spatial resolution. Here, we compare a state-of-the art model with 30 prognostic tracers (TOPAZ) with two reduced-tracer models, one with 6 tracers (BLING), and the other with 3 tracers (miniBLING). The reduced-tracer models employ parameterized, implicit biological functions, which nonetheless capture many of the most important processes resolved by TOPAZ. All three are embedded in the same coupled climate model. Despite the large difference in tracer number, the absence of tracers for living organic matter is shown to have a minimal impact on the transport of nutrient elements, and the three models produce similar mean annual preindustrial distributions of macronutrients, oxygen, and carbon. Significant differences do exist among the models, in particular the seasonal cycle of biomass and export production, but it does not appear that these are necessary consequences of the reduced tracer number. With increasing CO2, changes in dissolved oxygen and anthropogenic carbon uptake are very similar across the different models. Thus, while the reduced-tracer models do not explicitly resolve the diversity and internal dynamics of marine ecosystems, we demonstrate that such models are applicable to a broad suite of major biogeochemical concerns, including anthropogenic change. These results are very promising for the further development and application of reduced-tracer biogeochemical models that incorporate "sub-ecosystem-scale" parameterizations.

  14. 15N tracer kinetic studies on the validity of various 15N tracer substances for determining whole-body protein parameters in very small preterm infants

    International Nuclear Information System (INIS)

    Plath, C.; Heine, W.; Wutzke, K.D.; Krienke, L.; Toewe, J.M.; Massute, G.; Windischmann, C.

    1987-01-01

    Reliable 15 N tracer substances for tracer kinetic determination of whole-body protein parameters in very small preterm infants are still a matter of intensive research, especially after some doubts have been raised about the validity of [ 15 N]glycine, a commonly used 15 N tracer. Protein turnover, synthesis, breakdown, and further protein metabolism data were determined by a paired comparison in four preterm infants. Their post-conceptual age was 32.2 +/- 0.8 weeks, and their body weight was 1670 +/- 181 g. Tracer substances applied in this study were a [ 15 N]amino acid mixture (Ia) and [ 15 N]glycine (Ib). In a second group of three infants with a post conceptual age of 15 N-labeled 32.0 +/- 1.0 weeks and a body weight of 1,907 +/- 137 g, yeast protein hydrolysate (II) was used as a tracer substance. A three-pool model was employed for the analysis of the data. This model takes into account renal and fecal 15 N losses after a single 15 N pulse. Protein turnovers were as follows: 11.9 +/- 3.1 g kg-1 d-1 (Ia), 16.2 +/- 2.5 g kg-1 d-1 (Ib), and 10.8 +/- 3.0 g kg-1 d-1 (II). We were able to demonstrate an overestimation of the protein turnover when Ib was used. There was an expected correspondence in the results obtained from Ia and II. The 15 N-labeled yeast protein hydrolysate is a relatively cheap tracer that allows reliable determination of whole-body protein parameters in very small preterm infants

  15. SIMULASI JARINGAN KOMPUTER MENGGUNAKAN CISCO PACKET TRACER

    Directory of Open Access Journals (Sweden)

    M Mufadhol

    2012-01-01

    Full Text Available Perkembangan jaringan komputer saat ini begitu pesat, monitoring jaringan komputer akan menjadi suatu hal yang sulit dan rumit. Koneksi jaringan komputer merupakan suatu hal yang mendasar dalam suatu jaringan, karena bila koneksi itu bermasalah maka semua jenis aplikasi yang dijalankan melalui jaringan komputer tidak dapat digunakan. Cisco packet tracer dapat digunakan untuk simulasi yang mencerminkan arsitektur dan juga model dari jaringan komputer pada sistem jaringan yang digunakan. Dengan menggunakan aplikasi cisco packet tracer, simulasi mengenai jaringan dapat dimanfaatkan menjadi informasi tentang keadaan koneksi komputer dalam suatu jaringan.

  16. Development and application of a modified wireless tracer for disaster prevention

    Science.gov (United States)

    Chung Yang, Han; Su, Chih Chiang

    2016-04-01

    Typhoon-induced flooding causes water overflow in a river channel, which results in general and bridge scour and soil erosion, thus leading to bridge failure, debris flow and landslide collapse. Therefore, dynamic measurement technology should be developed to assess scour in channels and landslide as a disaster-prevention measure against bridge failure and debris flow. This paper presents a wireless tracer that enables monitoring general scour in river channels and soil erosion in hillsides. The wireless tracer comprises a wireless high-power radio modem, various electronic components, and a self-designed printed circuit board that are all combined with a 9-V battery pack and an auto switch. The entire device is sealed in a jar by silicon. After it was modified, the wireless tracer underwent the following tests for practical applications: power continuation and durability, water penetration, and signal transmission during floating. A regression correlation between the wireless tracer's transmission signal and distance was also established. This device can be embedded at any location where scouring is monitored, and, in contrast to its counterparts that detect scour depth by identifying and analyzing received signals, it enables real-time observation of the scouring process. In summary, the wireless tracer developed in this study provides a dynamic technology for real-time monitoring of scouring (or erosion) and forecasting of landslide hazards. Keywords: wireless tracer; scour; real-time monitoring; landslide hazard.

  17. A conductance maximum observed in an inward-rectifier potassium channel

    OpenAIRE

    1994-01-01

    One prediction of a multi-ion pore is that its conductance should reach a maximum and then begin to decrease as the concentration of permeant ion is raised equally on both sides of the membrane. A conductance maximum has been observed at the single-channel level in gramicidin and in a Ca(2+)-activated K+ channel at extremely high ion concentration (> 1,000 mM) (Hladky, S. B., and D. A. Haydon. 1972. Biochimica et Biophysica Acta. 274:294-312; Eisenmam, G., J. Sandblom, and E. Neher. 1977. In ...

  18. First preclinical evaluation of mono-[{sup 123}I]iodohypericin as a necrosis-avid tracer agent

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Yicheng; Chen, Feng; Marchal, Guy [University Hospital Gasthuisberg, Department of Radiology, Leuven (Belgium); Huyghe, Dieter; Verbeke, Kristin; Verbruggen, Alfons M.; Bormans, Guy M. [University of Leuven, Laboratory of Radiopharmaceutical Chemistry, Faculty of Pharmaceutical Sciences, Leuven (Belgium); Witte, Peter A. de [University of Leuven, Laboratory of Pharmaceutical Biology and Phytopharmacology, Faculty of Pharmaceutical Sciences, Leuven (Belgium); Nuyts, Johan; Mortelmans, Luc [University Hospital Gasthuisberg, Department of Nuclear Medicine, Leuven (Belgium)

    2006-05-15

    We have labelled hypericin, a polyphenolic polycyclic quinone found in St. John's wort (Hypericum perforatum), with{sup 123}I and evaluated mono-[{sup 123}I]iodohypericin (MIH) as a potential necrosis-avid diagnostic tracer agent. MIH was prepared by an electrophilic radioiodination method. The new tracer agent was evaluated in animal models of liver infarction in the rat and heart infarction in the rabbit using single-photon emission computed tomography (SPECT), triphenyltetrazolium chloride (TTC) histochemical staining, serial sectional autoradiography and microscopy, and radioactivity counting techniques. Using in vivo SPECT imaging, hepatic and cardiac infarctions were persistently visualised as well-defined hot spots over 48 h. Preferential uptake of the tracer agent in necrotic tissue was confirmed by perfect match of images from post-mortem TTC staining, autoradiography (ARX) and histology. Radioactivity concentration in infarcted tissues was over 10 times (liver; 3.51% ID/g in necrotic tissue vs 0.38% ID/g in normal tissue at 60 h p.i.) and over 6 times (myocardium; 0.36% ID/g in necrotic tissue vs 0.054% ID/g in normal tissue; ratios up to 18 for selected parts on ARX images) higher than in normal tissues. The results suggest that hypericin derivatives may serve as powerful necrosis-avid diagnostic agents for assessment of tissue viability. (orig.)

  19. Methane emission quantification from landfills using a double tracer approach

    DEFF Research Database (Denmark)

    Scheutz, Charlotte; Samuelsson, J.; Fredenslund, Anders Michael

    2007-01-01

    A tracer method was successfully used for quantification of the whole methane (CH4) emission from Fakse landfill. By using two different tracers the emission from different sections of the landfill could be quantified. Furthermore, is was possible to determine the emissions from local on site...

  20. Field and Laboratory Tests of Chromium-51-EDTA and Tritium Water as a Double Tracer for Groundwater Flow

    International Nuclear Information System (INIS)

    Knutsson, G.; Uunggren, K.; Forsberg, H. G.

    1963-01-01

    Since 1958 field experiments and laboratory tests have been made in a study of groundwater flow in different geological and mineralogical environments by the use of gamma-emitting tracers ana tritium water. The velocity of groundwater flow in soil is rather low, and tracers with medium or long half-life must be chosen to trace the movement. A stable EDTA-complex of Cr 51 (half-life 28 d) was developed for this purpose and used together with tritium water. With this double tracer it was possible to follow the groundwater flow by measurement of the gamma radiation from Cr 51 directly in the field and thereby to reduce the number of water samples for precise laboratory assessment. By comparison of the measured activities of Cr 51 and tritium it was possible to determine whether there was any retardation or loss of the chromium complex as a result of adsorption. Six field investigations, each of about two months' duration, have been made in glacifluvial sand and gravel. The results from these show that the chromium complex is transported as rapidly as the tritium water is, even at low concentrations (0. 01 ppm) of the complex. 17 field investigations of one to three months' duration with this double tracer have been carried out in various till (moraine) soils for a study of certain hydrological problems. Laboratory tests with soil and water from the various areas of field investigations have shown that the chromium complex does not hydrolyse at concentrations above 0.01 ppm. Further laboratory tests of the reliability of the chromium complex in different mineralogical environments are in progress. A number of investigations of groundwater flow through fissures and channels have abo been made. When the velocity of flow was assumed to be very high, Br 82 as bromide ion or Rhodamine-B, a fluorescent organic dye, were used. EDTA-Cr 51 and tritium water were, however, used when the velocity was considered low or when, as in karst, a great number of channels or large

  1. Wine ethanol C-14 as a tracer for fossil fuel CO2 emissions in Europe : Measurements and model comparison

    NARCIS (Netherlands)

    Palstra, Sanne W. L.; Karstens, Ute; Streurman, Harm-Jan; Meijer, Harro A. J.

    2008-01-01

    C-14 (radiocarbon) in atmospheric CO2 is the most direct tracer for the presence of fossil-fuel-derived CO2 (CO2-ff). We demonstrate the C-14 measurement of wine ethanol as a way to determine the relative regional atmospheric CO2-ff concentration compared to a background site ("regional CO2-ff

  2. Caffeine in Boston Harbor past and present, assessing its utility as a tracer of wastewater contamination in an urban estuary

    Science.gov (United States)

    Sites throughout Boston Harbor were analyzed for caffeine to assess its utility as a tracer in identifying sources of sanitary wastewater. Caffeine ranged from 15 ng/L in the outer harbor to a high of 185 ng/L in the inner harbor. Inner harbor concentrations were a result of comb...

  3. An experimental study of tracers for labelling of injection gas in oil reservoirs

    International Nuclear Information System (INIS)

    Dugstad, Oe.

    1992-01-01

    This work demonstrates the feasibility of the PMCP and PMCH as tracers in field experiments. These compounds have properties which make them as well suited for well to well studies as the more common tracers CH 3 T and 85 Kr. In an injection project carried out at the Gullfaks field in the North Sea the two PFCs verified communication between wells. This implies communication between different geological layers in the reservoir and also communication across faults within the same layers. Laboratory studies carried out have focused on the retention of the tracers in dynamic flooding experiments under conditions comparable with those in the petroleum reservoirs. Simultaneous injection of a variety of tracers has shown individual variations in tracer retention which are caused by important reservoir parameters as fluid saturation and rock properties. By proper design of field injection programs the tracers response may therefore be used to estimate fluid saturation if actual rock properties are known. 45 refs., 20 figs., 13 tabs

  4. MAK and BAT values list 2015. Maximum permissible concentrations at the place of work and biological tolerance values for working materials; MAK- und BAT-Werte-Liste 2015. Maximale Arbeitsplatzkonzentrationen und Biologische Arbeitsstofftoleranzwerte

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-11-01

    The book on the MAK (maximum permissible concentrations at the place of work) and BAT (biological tolerance values for working materials) value list 2015 includes the following chapters: (a) Maximum permissible concentrations at the place of work: definition, application and determination of MAT values, list of materials; carcinogenic working materials, sensibilizing working materials, aerosols, limiting the exposition peaks, skin resorption, MAK values during pregnancy, germ cell mutagens, specific working materials; (b) Biological tolerance values for working materials: definition and application of BAT values, list of materials, carcinogenic working materials, biological guide values, biological working material reference values.

  5. MAK and BAT values list 2014. Maximum permissible concentrations at the place of work and biological tolerance values for working materials; MAK- und BAT-Werte-Liste 2014. Maximale Arbeitsplatzkonzentrationen und Biologische Arbeitsstofftoleranzwerte

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-11-01

    The book on the MAK (maximum permissible concentrations at the place of work) and BAT (biological tolerance values for working materials) value list 2014 includes the following chapters: (a) Maximum permissible concentrations at the place of work: definition, application and determination of MAT values, list of materials; carcinogenic working materials, sensibilizing working materials, aerosols, limiting the exposition peaks, skin resorption, MAK values during pregnancy, germ cell mutagens, specific working materials; (b) Biological tolerance values for working materials: definition and application of BAT values, list of materials, carcinogenic working materials, biological guide values, biological working material reference values.

  6. MAK and BAT values list 2013. Maximum permissible concentrations at the place of work and biological tolerance values for working materials; MAK- und BAT-Werte-Liste 2013. Maximale Arbeitsplatzkonzentrationen und Biologische Arbeitsstofftoleranzwerte

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-01

    The book on the MAK (maximum permissible concentrations at the place of work) and BAT (biological tolerance values for working materials) value list 2013 includes the following chapters: (a) Maximum permissible concentrations at the place of work: definition, application and determination of MAT values, list of materials; carcinogenic working materials, sensibilizing working materials, aerosols, limiting the exposition peaks, skin resorption, MAK values during pregnancy, germ cell mutagens, specific working materials; (b) Biological tolerance values for working materials: definition and application of BAT values, list of materials, carcinogenic working materials, biological guide values, biological working material reference values.

  7. Pushing concentration of stationary solar concentrators to the limit.

    Science.gov (United States)

    Winston, Roland; Zhang, Weiya

    2010-04-26

    We give the theoretical limit of concentration allowed by nonimaging optics for stationary solar concentrators after reviewing sun- earth geometry in direction cosine space. We then discuss the design principles that we follow to approach the maximum concentration along with examples including a hollow CPC trough, a dielectric CPC trough, and a 3D dielectric stationary solar concentrator which concentrates sun light four times (4x), eight hours per day year around.

  8. Ambiguity in measuring matrix diffusion with single-well injection/recovery tracer tests

    Science.gov (United States)

    Lessoff, S.C.; Konikow, Leonard F.

    1997-01-01

    Single-well injection/recovery tracer tests are considered for use in characterizing and quantifying matrix diffusion in dual-porosity aquifers. Numerical modeling indicates that neither regional drift in homogeneous aquifers, nor heterogeneity in aquifers having no regional drift, nor hydrodynamic dispersion significantly affects these tests. However, when drift is coupled simultaneously with heterogeneity, they can have significant confounding effects on tracer return. This synergistic effect of drift and heterogeneity may help explain irreversible flow and inconsistent results sometimes encountered in previous single-well injection/recovery tracer tests. Numerical results indicate that in a hypothetical single-well injection/recovery tracer test designed to demonstrate and measure dual-porosity characteristics in a fractured dolomite, the simultaneous effects of drift and heterogeneity sometimes yields responses similar to those anticipated in a homogeneous dual-porosity formation. In these cases, tracer recovery could provide a false indication of the occurrence of matrix diffusion. Shortening the shut-in period between injection and recovery periods may make the test less sensitive to drift. Using multiple tracers having different diffusion characteristics, multiple tests having different pumping schedules, and testing the formation at more than one location would decrease the ambiguity in the interpretation of test data.

  9. The use of radioactive and other tracers in oil and gas measurement

    International Nuclear Information System (INIS)

    Edmonds, E.A.

    1985-01-01

    A description and critical discussion of the use of tracer techniques of flowrate measurement in the oil and gas industries. Radioactive tracers are discussed in particular, with emphasis on the practical aspects of their use. Radiotracers suitable for use in industrial environments are described and discussed. The advantages of radiotracers over conventional chemical tracers are reviewed and the logistical problems associated with the use of radioactive materials are considered. The results of measurements conducted using radiotracers on operating plant and on calibration facilities are presented with a discussion of the accuracy of measurement of flowrate which is achievable: potentially, in ideal circumstances, and in practical situations. The modification of tracer techniques of flow measurement to enable residence time distributions to be evaluated and leaks to be located and quantified on operating process plant is illustrated and discussed. The use of specially synthesized radiochemicals for tracing complex petrochemical processes involving chemical reactions and multiproduct streams is described. The use of novel non-radioactive tracers and specialized detection systems is also described, again with practical illustrations of experience in the field. The benefits offered by the use of these tracers and the limitations encountered are discussed. (author)

  10. Tracer SWIW tests in propped and un-propped fractures: parameter sensitivity issues, revisited

    Science.gov (United States)

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2017-04-01

    Single-well injection-withdrawal (SWIW) or 'push-then-pull' tracer methods appear attractive for a number of reasons: less uncertainty on design and dimensioning, and lower tracer quantities required than for inter-well tests; stronger tracer signals, enabling easier and cheaper metering, and shorter metering duration required, reaching higher tracer mass recovery than in inter-well tests; last not least: no need for a second well. However, SWIW tracer signal inversion faces a major issue: the 'push-then-pull' design weakens the correlation between tracer residence times and georeservoir transport parameters, inducing insensitivity or ambiguity of tracer signal inversion w. r. to some of those georeservoir parameters that are supposed to be the target of tracer tests par excellence: pore velocity, transport-effective porosity, fracture or fissure aperture and spacing or density (where applicable), fluid/solid or fluid/fluid phase interface density. Hydraulic methods cannot measure the transport-effective values of such parameters, because pressure signals correlate neither with fluid motion, nor with material fluxes through (fluid-rock, or fluid-fluid) phase interfaces. The notorious ambiguity impeding parameter inversion from SWIW test signals has nourished several 'modeling attitudes': (i) regard dispersion as the key process encompassing whatever superposition of underlying transport phenomena, and seek a statistical description of flow-path collectives enabling to characterize dispersion independently of any other transport parameter, as proposed by Gouze et al. (2008), with Hansen et al. (2016) offering a comprehensive analysis of the various ways dispersion model assumptions interfere with parameter inversion from SWIW tests; (ii) regard diffusion as the key process, and seek for a large-time, asymptotically advection-independent regime in the measured tracer signals (Haggerty et al. 2001), enabling a dispersion-independent characterization of multiple

  11. A degradation approach to accelerate simulations to steady-state in a 3-D tracer transport model of the global ocean

    Energy Technology Data Exchange (ETDEWEB)

    Aumont, O.; Orr, J.C.; Marti, O. [CEA Saclay, Gif-sur-Yvette (France). Lab. de Modelisation du Climat et de l`Environnement; Jamous, D.; Monfray, P. [Centre des Faibles Radioactivites, Laboratoire mixte CNRS-CEA, L`Orme des Merisiers, Bt. 709/LMCE, CE Saclay, F-91191 Gif sur Yvette Cedex (France); Madec, G. [Laboratoire d`Oceanographie Dynamique et de Climatologie, (CNRS/ORSTOM/UPMC) Universite Paris VI, 4 place Jussieu, Paris (France)

    1998-02-01

    We have developed a new method to accelerate tracer simulations to steady-state in a 3D global ocean model, run off-line. Using this technique, our simulations for natural {sup 14}C ran 17 times faster when compared to those made with the standard nonaccelerated approach. For maximum acceleration we wish to initialize the model with tracer fields that are as close as possible to the final equilibrium solution. Our initial tracer fields were derived by judiciously constructing a much faster, lower-resolution (degraded), off-line model from advective and turbulent fields predicted from the parent on-line model, an ocean general circulation model (OGCM). No on-line version of the degraded model exists; it is based entirely on results from the parent OGCM. Degradation was made horizontally over sets of four adjacent grid-cell squares for each vertical layer of the parent model. However, final resolution did not suffer because as a second step, after allowing the degraded model to reach equilibrium, we used its tracer output to reinitialize the parent model (at the original resolution). After reinitialization, the parent model must then be integrated only to a few hundred years before reaching equilibrium. To validate our degradation-integration technique (DEGINT), we compared {sup 14}C results from runs with and without this approach. Differences are less than 10 permille throughout 98.5% of the ocean volume. Predicted natural {sup 14}C appears reasonable over most of the ocean. In the Atlantic, modeled {Delta}{sup 14}C indicates that as observed, the North Atlantic Deep Water (NADW) fills the deep North Atlantic, and Antartic Intermediate Water (AAIW) infiltrates northward. (orig.) With 12 figs., 1 tab., 42 refs.

  12. Results of repeat tracer tests at Ohaaki, NZ

    International Nuclear Information System (INIS)

    McCabe, W.J.; Morris, C.

    1995-01-01

    During 20 years of tracer testing at Ohaaki a number of wells have been used more than once as tracer injection sites. In studying the various responses obtained it has been necessary to consider variations in the experimental test conditions before making comparisons which relate to field conditions. Some very significant changes have occurred in the field hydrology in recent years and water flow speeds as high as those encountered at Wairakei have been demonstrated. (author). 4 refs., 2 tabs., 10 figs

  13. Feasibility of using sodium chloride as a tracer for the characterization of the distribution of matter in complex multi-compartment 3D bioreactors for stem cell culture.

    Science.gov (United States)

    Gerlach, Jörg C; Witaschek, Tom; Strobel, Catrin; Brayfield, Candace A; Bornemann, Reinhard; Catapano, Gerardo; Zeilinger, Katrin

    2010-06-01

    The experimental characterization of the distribution of matter in complex multi-compartment three-dimensional membrane bioreactors for human cell culture is complicated by tracer interactions with the membranes and other bioreactor constituents. This is due to the fact that membranes with a high specific surface area often feature a hydrophobic chemical backbone that may adsorb tracers often used to this purpose, such as proteins and dyes. Membrane selectivity, and its worsening caused by protein adsorption, may also hinder tracer transfer across neighboring compartments, thus preventing effective characterization of the distribution of matter in the whole bioreactor. Tracer experiments with sodium chloride (NaCl) may overcome some of these limitations and be effectively used to characterize the distribution of matter in complex 3D multi-compartments membrane bioreactors for stem cell culture. NaCl freely permeates most used membranes, it does not adsorb on uncharged membranes, and its concentration may be accurately measured in terms of solution conductivity. In this preliminary study, the feasibility of complex multi-compartment membrane bioreactors was investigated with a NaCl concentration pulse challenge to characterize how their distribution of matter changes when they are operated under different conditions. In particular, bioreactors consisting of three different membrane types stacked on top of one another to form a 3D network were characterized under different feed conditions.

  14. Evolution of the electrical resistivity anisotropy during saline tracer tests: insights from geoelectrical milli-fluidic experiments

    Science.gov (United States)

    Jougnot, D.; Jimenez-Martinez, J.; Legendre, R.; Le Borgne, T.; Meheust, Y.; Linde, N.

    2017-12-01

    The use of time-lapse electrical resistivity tomography has been largely developed in environmental studies to remotely monitor water saturation and contaminant plumes migration. However, subsurface heterogeneities, and corresponding preferential transport paths, yield a potentially large anisotropy in the electrical properties of the subsurface. In order to study this effect, we have used a newly developed geoelectrical milli-fluidic experimental set-up with a flow cell that contains a 2D porous medium consisting of a single layer of cylindrical solid grains. We performed saline tracer tests under full and partial water saturations in that cell by jointly injecting air and aqueous solutions with different salinities. The flow cell is equipped with four electrodes to measure the bulk electrical resistivity at the cell's scale. The spatial distribution of the water/air phases and the saline solute concentration field in the water phase are captured simultaneously with a high-resolution camera by combining a fluorescent tracer with the saline solute. These data are used to compute the longitudinal and transverse effective electrical resistivity numerically from the measured spatial distributions of the fluid phases and the salinity field. This approach is validated as the computed longitudinal effective resistivities are in good agreement with the laboratory measurements. The anisotropy in electrical resistivity is then inferred from the computed longitudinal and transverse effective resistivities. We find that the spatial distribution of saline tracer, and potentially air phase, drive temporal changes in the effective resistivity through preferential paths or barriers for electrical current at the pore scale. The resulting heterogeneities in the solute concentrations lead to strong anisotropy of the effective bulk electrical resistivity, especially for partially saturated conditions. Therefore, considering the electrical resistivity as a tensor could improve our

  15. Considerations on the assessment of economic benefits of industrial tracer application

    International Nuclear Information System (INIS)

    Guizerix, J.; Margrita, R.

    1990-01-01

    The benefit of a particular tracer study which can always theoretically be derived is practically very difficult to assess for decision-making which is more often based on rough estimates of it. Other criteria, as safety, environmental protection, 'social benefit', may replace the purely economic considerations. The economic benefits of industrial tracer applications can clearly be perceived through the commercial success of businesses offering tracer services, which implies that all factors involved in the law of supply and demand have (tacitly or explictly) been accounted. (orig.) [de

  16. Tritium as tracer of flow in constructed wetlands

    International Nuclear Information System (INIS)

    Wachniew, P.; Czuprynski, P.; Maloszewski, P.

    2005-01-01

    Constructed wetlands technology is a cost-effective and environmentally friendly method used world-wide to treat waste waters of different origins. The soluble pollutants are transformed and removed mainly through the processes that occur at surfaces of plants, plant debris or filtering media. The efficiency of soluble pollutants removal is thus primarily related to the extent of contact between waste waters and the reactive surfaces. Residence time distributions function (RTD)is basic characteristic of wetland hydraulic properties and can be obtained by combined use of tracer technique and mathematical modelling. Tritium was used as to obtain RTD's of three parallel cells of a sub-surface flow constructed wetland overgrown with Pharagmites australis in Nowa Slupia. Tritium as a part of water molecule, is an ideal tracer of flow in the highly reactive environment of constructed wetlands. Results of the tracer test interpreted by the assumed model (Multi Flow Dispersion Model) of conservative solute transport revealed a complex structure of flow through the wetland. (author)

  17. Synthesis of tracers using automated radiochemistry and robotics

    International Nuclear Information System (INIS)

    Dannals, R.F.

    1992-07-01

    Synthesis of high specific activity radiotracers labeled with short-lived positron-emitting radionuclides for positron emission tomography (PET) often requires handling large initial quantities of radioactivity. High specific activities are required when preparing tracers for use in PET studies of neuroreceptors. A fully automated approach for tracer synthesis is highly desirable. This proposal involves the development of a system for the Synthesis of Tracers using Automated Radiochemistry and Robotics (STARR) for this purpose. While the long range objective of the proposed research is the development of a totally automated radiochemistry system for the production of major high specific activity 11 C-radiotracers for use in PET, the specific short range objectives are the automation of 11 C-methyl iodide ( 11 CH 3 I) production via an integrated approach using both radiochemistry modular labstations and robotics, and the extension of this automated capability to the production of several radiotracers for PET (initially, 11 C-methionine, 3-N-[ 11 C-methyl]spiperone, and [ 11 C]-carfentanil)

  18. Novel tracer for radiation treatment planning

    International Nuclear Information System (INIS)

    Schwarzenboeck, S.; Krause, B.J.; Herrmann, K.; Gaertner, F.; Souvatzoglou, M.; Klaesner, B.

    2011-01-01

    PET and PET/CT with innovative tracers gain increasing importance in diagnosis and therapy management, and radiation treatment planning in radio-oncology besides the widely established FDG. The introduction of [ 18 F]Fluorothymidine ([ 18 F]FLT) as marker of proliferation, [ 18 F]Fluoromisonidazole ([ 18 F]FMISO) and [ 18 F]Fluoroazomycin-Arabinoside ([ 18 F]FAZA) as tracer of hypoxia, [ 18 F]Fluoroethyltyrosine ([ 18 F]FET) and [ 11 C]Methionine for brain tumour imaging, [ 68 Ga]DOTATOC for somatostatin receptor imaging, [ 18 F]FDOPA for dopamine synthesis and radioactively labeled choline derivatives for imaging phospholipid metabolism have opened novel approaches to tumour imaging. Some of these tracers have already been implemented into radio-oncology: Amino acid PET and PET/CT have the potential to optimise radiation treatment planning of brain tumours through accurate delineation of tumour tissue from normal tissue, necrosis and edema. Hypoxia represents a major therapeutic problem in radiation therapy. Hypoxia imaging is very attractive as it may allow to increase the dose in hypoxic tumours potentially allowing for a better tumour control. Advances in hybrid imaging, i.e. the introduction of MR/PET, may also have an impact in radio-oncology through synergies related to the combination of molecular signals of PET and a high soft tissue contrast of MRI as well as functional MRI capabilities. (orig.)

  19. TMI cable tracer operation and maintenance manual for assembly 417910

    International Nuclear Information System (INIS)

    Sumstine, R.L.

    1983-11-01

    This manual provides technical information and instructions to operate and maintain the cable tracer designed for the Three Mile Island (TMI) Unit 2 Reactor Building. The TMI cable tracer was developed to allow TMI personnel to trace cables in cable trays that may be tested or sectioned for destructive examination

  20. Effect of paracentesis on ocular cloxacillin concentration

    International Nuclear Information System (INIS)

    Salminen, L.

    1978-01-01

    The effect of interior chamber puncture on cloxacillin concentration in the rabbit eye after intravenous injection was studied using a radioactive tracer method. The enhancement in drug concentration caused by paracentesis was most immediate and significant in the iris-ciliary body preparation. It was soon followed by high cloxacillin concentration in the aqueous humour, which contributed to elevated cloxacillin levels in the cornea, lens and anterior vitreous body, when compared to normal material. Contrary to normal eyes, cloxacillin concentration in the cornea of the punctured eyes was higher than in the limbal area. The morphological changes occurring after paracentesis are discussed. The breakdown of the hydrodynamic equilibrium in the eye, suggested as the only change after paracentesis by Raviola (1974), cannot merely explain the cloxacillin concentration changes measured in the punctured eye. (author)